WorldWideScience

Sample records for portal system final

  1. Liferay Portal Systems Development

    CERN Document Server

    Yuan, Jonas X

    2012-01-01

    This book focuses on teaching by example. Every chapter provides an overview, and then dives right into hands-on examples so you can see and play with the solution in your own environment. This book is for Java developers who don't need any prior experience with Liferay portal. Although Liferay portal makes heavy use of open source frameworks, no prior experience of using these is assumed.

  2. Portal hemodynamics in chronic portal-systemic encephalopathy

    International Nuclear Information System (INIS)

    Takashi, Motohide; Igarashi, Masahiko; Hino, Shinichi; Takayasu, Kenichi; Goto, Nobuaki; Musha, Hirotaka; Ohnishi, Kunihiko; Okuda, Kunio

    1985-01-01

    A portal hemodynamic study was made in 7 consecutive patients with chronic portal-systemic encephalopathy by percutaneous transhepatic catheterization of the portal vein and injecting contrast medium into the superior mesenteric vein or by superior mesenteric arterial portography in comparison with patients without encephalopathy studied by percutaneous catheterization of these veins. It is suggested that chronic portal-systemic encephalopathy is a result of a large collateral route shunting a large proportion of the superior mesenteric venous blood into systemic circulation, and that development of such collaterals precludes formation of large esophageal varices. (Auth.)

  3. Uzbekistan Radiation Portal Monitoring System

    International Nuclear Information System (INIS)

    Richardson, J; Knapp, R; Loshak, A; Yuldashev, B; Petrenko, V

    2005-01-01

    The work proposed in this presentation builds on the foundation set by the DTRA funded demonstration project begun in 2000 and completed in December of 2003. This previous work consisted of two phases whose overall objective was to install portal radiation monitors at four select ports-of-entry in Uzbekistan (Tashkent International Airport, Gisht-Kuprik (Kazakhstan border), Alat (Turkmenistan border), and Termez (Afghanistan border)) in order to demonstrate their effectiveness in preventing the illicit trafficking of nuclear materials. The objectives also included developing and demonstrating capabilities in the design, installation, operation, training, and maintenance of a radiation portal monitoring system. The system and demonstration project has proved successful in many ways. An effective working relationship among the Uzbekistan Customs Services, Uzbekistan Border Guards, and Uzbekistan Institute of Nuclear Physics has been developed. There has been unprecedented openness with the sharing of portal monitor data with Lawrence Livermore National Laboratory. The system has proved to be effective, with detection of illicit trafficking, and, at Alat, an arrest of three persons illegally transporting radioactive materials into Turkmenistan. The demonstration project has made Uzbekistan a model nonproliferation state in Central Asia and, with an expanded program, places them in a position to seal a likely transit route for illicit nuclear materials. These results will be described. In addition, this work is currently being expanded to include additional ports-of-entry in Uzbekistan. The process for deciding on which additional ports-of-entry to equip will also be described

  4. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  5. Calcification in the portal venous system demonstrated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hadar, H; Sommer, R

    1983-08-01

    The CT appearance of calcification in the portal venous system in a patient with chronic alcoholic cirrhosis is presented. Reported cases of radiologically detectable calcification in the portal system are rare, and most of them have been associated with longstanding portal hypertension. We presume that with CT this diagnosis will be made more frequently. In the presence of calcification in the portal venous system, portal vein thrombosis is highly probable. This information is of obvious importance to the surgeon contemplating a portal decompressive shunt procedure.

  6. Predictive model of portal venous system thrombosis in cirrhotic portal hypertensive patients after splenectomy

    OpenAIRE

    He, Shasha; He, Fangping

    2015-01-01

    Objective: This study is to investigate the risk factors of portal venous system thrombosis (PVT) in patients with cirrhotic portal hypertension after splenectomy and to establish a Logistic regression prediction model. Methods: A total of 119 patients with cirrhotic portal hypertension were enrolled. Their clinical data was retrospectively analyzed. They were divided into PVT group (n = 18) and non-PVT group (n = 101). One-way analysis and multivariate Logistic regression analysis were perfo...

  7. Final Report for DOE Project: Portal Web Services: Support of DOE SciDAC Collaboratories

    Energy Technology Data Exchange (ETDEWEB)

    Mary Thomas, PI; Geoffrey Fox, Co-PI; Gannon, D; Pierce, M; Moore, R; Schissel, D; Boisseau, J

    2007-10-01

    Grid portals provide the scientific community with familiar and simplified interfaces to the Grid and Grid services, and it is important to deploy grid portals onto the SciDAC grids and collaboratories. The goal of this project is the research, development and deployment of interoperable portal and web services that can be used on SciDAC National Collaboratory grids. This project has four primary task areas: development of portal systems; management of data collections; DOE science application integration; and development of web and grid services in support of the above activities.

  8. Corporate portal system at PAKS NPP, Hungary

    International Nuclear Information System (INIS)

    2009-01-01

    The new Corporate Portal System (CPS) of Paks NPP was launched in November 2006. The portal is based on one of the latest technologies, Plumtree Enterprise WEB 5.0. The main purpose of the installation of the new technology was to serve the working culture change, to give a platform to access all information and applications including the integrated process model used at the NPP. The new technology also supports those goals which were defined in the organization development programme: e.g. to improve internal communication with the establishment of communities of practice. Installation of the CPS has provided a powerful tool for knowledge management; it is possible to share and find all information through a controlled access in documents from various sources, to have links to people, portlets and different communities. Document management of the Paks NPP is supported by the integration of the Document 5 application, as the new Electronic Data Management System (EDMS) and the CPS. Depending on their access rights, all users of the CPS, through Microsoft Internet Explorer, can access technical, economic and human resources documents which are stored anywhere on the internal network (file servers, EDMS, old INRANET). The CPS is also accessible from the internet through a secure connection. The main concept is the integration of all applications to one platform and to help users to find all information they need. An access control list specifies which users and groups have access to an object (and what kind of access privileges they have such as read, select, edit, admin)

  9. Interface methods for using intranet portal organizational memory information system.

    Science.gov (United States)

    Ji, Yong Gu; Salvendy, Gavriel

    2004-12-01

    In this paper, an intranet portal is considered as an information infrastructure (organizational memory information system, OMIS) supporting organizational learning. The properties and the hierarchical structure of information and knowledge in an intranet portal OMIS was identified as a problem for navigation tools of an intranet portal interface. The problem relates to navigation and retrieval functions of intranet portal OMIS and is expected to adversely affect user performance, satisfaction, and usefulness. To solve the problem, a conceptual model for navigation tools of an intranet portal interface was proposed and an experiment using a crossover design was conducted with 10 participants. In the experiment, a separate access method (tabbed tree tool) was compared to an unified access method (single tree tool). The results indicate that each information/knowledge repository for which a user has a different structural knowledge should be handled separately with a separate access to increase user satisfaction and the usefulness of the OMIS and to improve user performance in navigation.

  10. Developing patient portals in a fragmented healthcare system.

    Science.gov (United States)

    Otte-Trojel, Terese; de Bont, Antoinette; Aspria, Marcello; Adams, Samantha; Rundall, Thomas G; van de Klundert, Joris; de Mul, Marleen

    2015-10-01

    Use of patient portals may contribute to improved patient health and experiences and better organizational performance. In the Netherlands, patient portals have gained considerable attention in recent years, as evidenced by various policy initiatives and practical efforts directed at developing portals. Due to the fragmented setup of the Dutch healthcare system patient portals that give patients access to information and services from across their providers are developed in inter-organizational collaboration. The objective of this paper is to identify and describe the types of collaborations, or networks, that have been established to develop patient portals in the Netherlands. Understanding the characteristics of these networks as well as the development of their respective portals enables us to assess the enabling and constraining effects of different network types on patient portal initiatives. We used qualitative methods including interview and documents analysis. In a first step, we interviewed eighteen experts and reviewed relevant national policy and strategy documents. Based on this orientation, we selected three networks we deemed to be representative of inter-organizational efforts to develop Dutch patient portals in 2012. In a second step, we interviewed twelve representatives of these patient portal networks and collected documents related to the portals. We applied content analytic techniques to analyze data from the three cases. The three studied networks differed in their number and diversity of actors, the degree to which these actors were mutually dependent, the degree to which network governance was decentralized, and the dynamics of the network structures. We observed that the portals developed in networks displaying the highest degree of these characteristics experienced most difficulties associated with developing patient portals - such as achieving interoperability, successful implementation, regulatory complaisance, and financial

  11. Global Mercury Observatory System Land-based Monitoring Data Portal

    Data.gov (United States)

    U.S. Environmental Protection Agency — Global Mercury Observation System On-line Data Portal. This dataset is associated with the following publication: Carbone, F., A. Bruno, A. Naccarato, F. De Simone,...

  12. An automated portal verification system for the tangential breast portal field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Lai, W.; Chen, C. W.; Nelson, D. F.

    1995-01-01

    Purpose/Objective: In order to ensure the treatment is delivered as planned, a portal image is acquired in the accelerator and is compared to the reference image. At present, this comparison is performed by radiation oncologists based on the manually-identified features, which is both time-consuming and potentially error-prone. With the introduction of various electronic portal imaging devices, real-time patient positioning correction is becoming clinically feasible to replace time-delayed analysis using films. However, this procedure requires present of radiation oncologists during patient treatment which is not cost-effective and practically not realistic. Therefore, the efficiency and quality of radiation therapy could be substantially improved if this procedure can be automated. The purpose of this study is to develop a fully computerized verification system for the radiation therapy of breast cancer for which a similar treatment setup is generally employed. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature correlation between reference and portal images, and quantitative evaluation of patient setup. In this study, a matrix liquid ion-chamber EPID was used to acquire digital portal images which is directly attached to Varian CL2100C accelerator. For effective use of computation memory, the 12-bit gray levels in original portal images were quantized to form a range of 8-bit gray levels. A typical breast portal image includes three important components: breast and lung tissues in the treatment field, air space within the treatment field, and non-irradiated region. A hierarchical region processing technique was developed to separate these regions sequentially. The inherent hierarchical features were formulated based on different radiation attenuation for different regions as: treatment field edge -- breast skin line -- chest wall. Initially, a combination of a Canny edge detector and a constrained

  13. Porto-systemic collaterals in cirrhosis of the liver. Selective percutaneous transhepatic catheterization of the portal venous system in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hoevels, J; Lunderquist, A; Tylen, U; Simert, G [Lund Univ. (Sweden)

    1979-01-01

    In 93 patients with cirrhosis of the liver and portal venous hypertension the main tributaries of the portal vein were examined by percutaneous transhepatic catheterization. The appearance and degree of porto-systemic collaterals were analysed. Esophageal varices were demonstrated in 82 patients. No correlation was found between the portal venous pressure and the extent of porto-systemic communications.

  14. Recommendation Systems for Geoscience Data Portals Built by Analyzing Usage Patterns

    Science.gov (United States)

    Crosby, C.; Nandigam, V.; Baru, C.

    2009-04-01

    selections. However, this paradigm has not yet been explored for geoscience data portals. In this presentation we will present an initial analysis of user interaction and access statistics for the GEON OpenTopography LiDAR data distribution and processing system to illustrate what they reveal about user's spatial and temporal data access patterns, data processing parameter selections, and pathways through the data portal. We also demonstrate what these usage statistics can illustrate about aspects of the data sets that are of greatest interest. Finally, we explore how these usage statistics could be used to improve the user's experience in the data portal and to optimize how data access interfaces and tools are designed and implemented.

  15. Quality Control of Mega Voltage Portal Imaging System

    International Nuclear Information System (INIS)

    Diklic, A.; Dundara Debeljuh, D.; Jurkovic, S.; Smilovic Radojcic, D.; Svabic Kolacio; Kasabasic, M.; Faj, D.

    2013-01-01

    The Electronic Portal Imaging Device (EPID) is a system used to verify either the correct positioning of the patient during radiotherapy treatment or the linear accelerator beam parameters. The correct position of the patient corresponds to the position at which the patient was scanned at the CT simulator and according to which the therapy plan was made and optimized. Regarding this, besides the advanced treatment planning system and optimized treatment planning techniques, the day-to-day reproduction of simulated conditions is of great importance for the treatment outcome. Therefore, to verify the patient set-up portal imaging should be applied prior to the first treatment session and repeated according to treatment prescriptions during the treatment. In order to achieve full functionality and precision of the EPID, it must be included in radiotherapy Quality Control (QC) programme. The QC of the Mega Voltage portal imaging system was separated in two parts. In the first, the QC of the detector parameters should be performed. For this purpose, the FC2 and QC3 phantoms should be used, along with the Portal Image Processing System program (PIPSpro) package for data analysis. The second part of the QC of the linear accelerator's portal imaging system should include the QC of the CBCT. In this part a set of predefined manufacturer's tests using two different phantoms, one for the geometry calibration and the other for the image quality evaluation, should be performed. Also, the treatment conditions should be simulated using anthropomorphic phantoms and dose distributions for particular EPID protocols should be measured. Procedures for quality control of the portal imaging system developed and implemented at University Hospital Rijeka are presented in this paper.(author)

  16. Climate Outreach Using Regional Coastal Ocean Observing System Portals

    Science.gov (United States)

    Anderson, D. M.; Hernandez, D. L.; Wakely, A.; Bochenek, R. J.; Bickel, A.

    2015-12-01

    Coastal oceans are dynamic, changing environments affected by processes ranging from seconds to millennia. On the east and west coast of the U.S., regional observing systems have deployed and sustained a remarkable diverse array of observing tools and sensors. Data portals visualize and provide access to real-time sensor networks. Portals have emerged as an interactive tool for educators to help students explore and understand climate. Bringing data portals to outreach events, into classrooms, and onto tablets and smartphones enables educators to address topics and phenomena happening right now. For example at the 2015 Charleston Science Technology Engineering and Math (STEM) Festival, visitors navigated the SECOORA (Southeast Coastal Ocean Observing regional Association) data portal to view the real-time marine meteorological conditions off South Carolina. Map-based entry points provide an intuitive interface for most students, an array of time series and other visualizations depict many of the essential principles of climate science manifest in the coastal zone, and data down-load/ extract options provide access to the data and documentation for further inquiry by advanced users. Beyond the exposition of climate principles, the portal experience reveals remarkable technologies in action and shows how the observing system is enabled by the activity of many different partners.

  17. Pulmonary hypertension associated with non-cirrhotic portal hypertension in systemic lupus erythematosus.

    OpenAIRE

    Woolf, D.; Voigt, M. D.; Jaskiewicz, K.; Kalla, A. A.

    1994-01-01

    A case of non-cirrhotic portal hypertension in a patient with systemic lupus erythematosus, the first of our knowledge, is described. Severe pulmonary hypertension was associated with the portal hypertension and with markers of active auto-immunity. Pulmonary hypertension has not previously been associated with non-cirrhotic portal hypertension. The coexistence of vasculopathy of the portal and pulmonary vascular beds in this patient with active autoimmunity supports the postulate that portal...

  18. DESM: portal for microbial knowledge exploration systems

    KAUST Repository

    Salhi, Adil

    2015-11-05

    Microorganisms produce an enormous variety of chemical compounds. It is of general interest for microbiology and biotechnology researchers to have means to explore information about molecular and genetic basis of functioning of different microorganisms and their ability for bioproduction. To enable such exploration, we compiled 45 topic-specific knowledgebases (KBs) accessible through DESM portal (www.cbrc.kaust.edu.sa/desm). The KBs contain information derived through text-mining of PubMed information and complemented by information data-mined from various other resources (e.g. ChEBI, Entrez Gene, GO, KOBAS, KEGG, UniPathways, BioGrid). All PubMed records were indexed using 4 538 278 concepts from 29 dictionaries, with 1 638 986 records utilized in KBs. Concepts used are normalized whenever possible. Most of the KBs focus on a particular type of microbial activity, such as production of biocatalysts or nutraceuticals. Others are focused on specific categories of microorganisms, e.g. streptomyces or cyanobacteria. KBs are all structured in a uniform manner and have a standardized user interface. Information exploration is enabled through various searches. Users can explore statistically most significant concepts or pairs of concepts, generate hypotheses, create interactive networks of associated concepts and export results. We believe DESM will be a useful complement to the existing resources to benefit microbiology and biotechnology research.

  19. Visualization of portal venous system by single photon emission CT

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, T; Ikawa, T; Azuma, M; Matsuda, H; Yoshioka, H; Mitsutani, N; Koizumi, T

    1987-03-01

    Single photon emission CT (SPECT) was performed for the intra-abdominal blood pool with /sup 99m/Tc autologous red blood cells (RBC) in 15 patients with liver cirrhosis. Twenty mCi of /sup 99m/Tc-RBC labeled by in vivo technique were administered intravenously and tomographic imaging of the intra-abdominal vascular blood pool was performed as follows. For each subject, 64 views were obtained over 360 deg of elliptic rotation at 30 seconds per view using a high resolution low energy parallel-hole collimator. Portal vein and portosystemic collaterals were clearly observed in coronal images. In 12 of 15 patients, portal vein was delineated. Portosystemic collaterals such as coronary vein, splenorenal shunt and umbilical vein were also shown in 12 patients. These images were consistent with images obtained by scintiphotosplenoportography or arterial portography. Therefore, it is considered that SPECT study for the intra-abdominal blood pool is clinically very useful for the diagnosis of abnormality of portal venous system in portal hypertension.

  20. Aligning Work Processes and the Adviser Portal Bank System

    DEFF Research Database (Denmark)

    Jørgensen, Jens Bæk; Lassen, Kristian Bisgaard

    2006-01-01

    The Adviser Portal (AP) is a new IT system for 15 Danish banks. The main goal of AP is to increase the efficiency and quality of bank advisers’ work. Re- quirements engineering for AP includes describing new work processes that must be supported by AP using a combination of: (1) prose and informal...... drawings; (2) The Adviser Portal (AP) is a new IT system for 15 Danish banks. The main goal of AP is to increase the efficiency and quality of bank advisers' work. Requirements engineering for AP includes describing new work processes that musty be supported by AP using a combination of: (1) prose...... and informal drawings; (2) formal models; (3) graphical animation. This representation helps users and system analysts to align new work processes and AP via early experiments in a prototyping fashion. The contribution of this paper is to present and reflect upon the analysis and descrition of one specific...

  1. Technical aspects of portal technology application for e-health systems.

    Science.gov (United States)

    Kosińska, Joanna; Słowikowski, Paweł

    2004-01-01

    E-health is an emerging field on the intersection of medical information technologies, public health and business, referring to health services and information delivered or enhanced through the Internet and related technologies. Portal technology, allowing services to be accessible over the Internet is a perfect tool for providing e-health services. The use of portal technologies has had deep influence on the architecture of the whole e-health system, both regarding new subsystems and older ones which we want to integrate with the portal. Portals provide new possibilities for creating novel types of e-health applications as well. In this paper we provide a brief overview of e-health systems and portal technologies, and present many technical aspects of portal technology application for e-health systems such as the architecture of portal-based e-health systems, graphical user interfaces, access to various e-health systems' resources, personalization, security and privacy.

  2. Anatomy of the Portal Vein Bifurcation: Implication for Transjugular Intrahepatic Portal Systemic Shunts

    International Nuclear Information System (INIS)

    Kwok, Philip Chong-hei; Ng, Wai Fu; Lam, Christine Suk-yee; Tsui, Polly Po; Faruqi, Asma

    2003-01-01

    Purpose: The relationship of the portalvein bifurcation to the liver capsule in Asians, which is an important landmark for transjugular intrahepatic portosystemic shunt, has not previously been described. Methods: The anatomy of the portal vein bifurcation was studied in 70 adult Chinese cadavers; it was characterized as intrahepatic or extrahepatic. The length of the exposed portion of the right and left portal veins was measured when the bifurcation was extrahepatic. Results: The portal vein bifurcation was intrahepatic in 37 cadavers (53%) and extrahepatic in 33 cadavers (47%). The mean length of the right and left extrahepatic portal veins was 0.96 cm and 0.85 cm respectively.Both were less than or equal to 2 cm in 94% of the cadavers with extrahepatic bifurcation. There was no correlation between the presence of cirrhosis and the location of the portal vein bifurcation(p 1.0). There was no statistically significant difference in liver mass in cadavers with either extrahepatic or intrahepatic bifurcation (p =0.40). Conclusions: These findings suggest that fortransjugular intrahepatic portosystemic shunt placement, a portal vein puncture 2 cm from the bifurcation will be safe in most cases

  3. The specialized portals in the knowledge transfer systems: the ionizing radiation portal http://www.ionizantes.ciemat.es/

    International Nuclear Information System (INIS)

    Arboli, M. Marco; Hernanz, Oscar; Couchoud Gregory, Milagros

    2008-01-01

    Full text: This paper shows the new infrastructure to disseminate RP knowledge and information developed by the community involved in radiation uses. The www.ionizantes.ciemat.es portal has been implemented by CIEMAT and CINDOC- CSIC with the support of the national and international organizations related to the radiation applications. The design and structure of the databases was developed by CIEMAT and CINDOC-CSIC using the experience acquired by both organizations in the knowledge transfer. The initiative aims to establish collaboration with the sector involved in the most important applications of the ionizing radiation uses. The goal is to share resources establishing a new system of information between the experts, researchers and public. The portal also brings the dialogue to the entire sector and provides details of the relevant research projects. The main specific objectives of this portal are: a) To inform about the new projects developed; b) To download publications, reports and papers; c) to learn more about ionizing radiation; d) To promote collaborative knowledge transfer. The portal shows particular relevance to representative international and national organizations, the private sector and the local community relevant organizations. Results: The resources include in the database of the portal are: the agenda, documents, research calls, legislation, research projects, most important journals and summaries, patents and other available tools. The information is presented in a categorized and classified structure. This virtual community offers better knowledge transfer. It also optimizes the communication and research dissemination to the society. (author)

  4. Development of integrated containment and surveillance system for fast critical facility FCA. Portal and penetration monitors

    International Nuclear Information System (INIS)

    Mukaiyama, Takehiko; Ogawa, Hironobu; Yokota, Yasuhiro.

    1998-01-01

    Manpower and radiation exposure problems, accompanied by frequent Non Destructive Assay (NDA) based inspections at the Fast Critical Facility FCA of Japan Atomic Energy Research Institute (JAERI), are a burden for both the inspectorates and the facility operator. In the hope of alleviating these burdens, the development of containment and surveillance measures for the FCA was initiated in 1979. The integrated containment and surveillance system consists of a portal monitor and a penetration monitor. The reactor building provides an ideal containment measure because of its explosion-proof, airtight structure and limited number of penetrations. The function of the portal monitor is to detect undeclared removal of nuclear material from the reactor building through the doorway. The penetration monitor is designed for surveillance of diversion routes through containment boundaries, and of safeguards related activities for bypassing the portal monitor. The combination of monitoring by the penetration monitor of containment boundaries and all their penetrations except for the doorway, and monitoring by the portal monitor, provides complete coverage of realistic diversion routes. The development of the system was completed in 1988 and the field trial test was conducted for the period of twelve running months. The final report on the field trial was concluded on January 1990. The major conclusion of the report was that the system is effective, reliable and efficient. Following this successful conclusion, the International Atomic Energy Agency (IAEA) accepted the system for meeting its safeguards goals at the FCA on condition that an independent IAEA authentication equipment is provided. The development of the authentication equipment is accomplished as an separate Japan Support Programme for Agency Safeguards (JASPAS) task. (author)

  5. A theoretical approach to calibrate radiation portal monitor (RPM) systems

    International Nuclear Information System (INIS)

    Nafee, Sherif S.; Abbas, Mahmoud I.

    2008-01-01

    Radiation portal monitor (RPM) systems are widely used at international border crossings, where they are applied to the task of detecting nuclear devices, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, the former being required to rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce [Chambers, W.H., Atwater, H.F., Fehlau, P.E., Hastings, R.D., Henry, C.N., Kunz, W.E., Sampson, T.E., Whittlesey, T.H., Worth, G.M., 1974. Portal Monitor for Diversion Safeguards. LA-5681, Los Alamos Scientific Laboratory, Los Alamos, NM]. In the present work, compact analytical formulae are derived and used to calibrate two RPM systems with isotropic radiating sources: (i) polyvinyltoluene (PVT) or plastic and (ii) thallium-doped crystalline sodium iodide, NaI(Tl), gamma-ray detector materials. The calculated efficiencies are compared to measured values reported in the literatures, showing very good agreement

  6. Evaluation of the portal venous system using MR angiography in patients with severe liver dysfunction

    International Nuclear Information System (INIS)

    Fukatsu, Hiroshi; Ando, Yoko; Yamakawa, Koji; Ishigaki, Takeo

    1994-01-01

    Fifteen patients of chronic liver dysfunction were examined with 2D TOF MR angiography to assess the portal venous system condition. All of the collateral pathways except esophageal varices were clearly demonstrated in all cases, portal vein thromboses were accurately diagnosed in two cases. Portal vein visualization index were determined as follows: good delineation of the main portal vein only; good delineation of the first tributaries of the intrahepatic portal vein; good delineation of the second or further tributaries. This index showed good correlation with the clinical stage proposed by Japan liver cancer study group. These results suggested that MR angiography has a potential for the evaluation of the portal system in patients with severe liver dysfunction. (author)

  7. A radiation-tolerant electronic readout system for portal imaging

    Science.gov (United States)

    Östling, J.; Brahme, A.; Danielsson, M.; Iacobaeus, C.; Peskov, V.

    2004-06-01

    A new electronic portal imaging device, EPID, is under development at the Karolinska Institutet and the Royal Institute of Technology. Due to considerable demands on radiation tolerance in the radiotherapy environment, a dedicated electronic readout system has been designed. The most interesting aspect of the readout system is that it allows to read out ˜1000 pixels in parallel, with all electronics placed outside the radiation beam—making the detector more radiation resistant. In this work we are presenting the function of a small prototype (6×100 pixels) of the electronic readout board that has been tested. Tests were made with continuous X-rays (10-60 keV) and with α particles. The results show that, without using an optimised gas mixture and with an early prototype only, the electronic readout system still works very well.

  8. Web-based service portal for decentral power supply systems. Remote monitoring and support of billing; Webbasiertes Service-Portal fuer dezentrale Energieanlagen. Fernueberwachung und Abrechnungsunterstuetzung

    Energy Technology Data Exchange (ETDEWEB)

    Silberg, Peter [EUS GmbH, Holzwickede (Germany); Bernemann, Andrew [MVV Energiedienstleistungen GmbH West, Solingen (Germany); Hillmann, Georg [Tema AG, Berlin (Germany)

    2010-01-15

    Web-based teleservice portals are a good basis for operating data acquisition and control of decentral power generation systems. They also provide a low-cost solution if open-source products are used. The authors present the teleservice portal of MVV Energiedinstleistungen GmbH that was developed by EUS GmbH. (orig.)

  9. Positive identity entry control system with geographically distributed portals and enrollment stations

    International Nuclear Information System (INIS)

    McIntire, J.M.

    1985-01-01

    A positive identity entry control system using distributed processing to allow reliable geographically separated portals and enrollment stations has been installed and is fully operational at a large area DOE site. Identity verification requires a credential, a memorized number and measurement of a physical characteristic of the user. Additionally, all portal activity is monitored by guards. The portal system is dual redundant such that no single point failure will shut down operations. Each portal site maintains its own subset of the master data base so off-site failure of the central data base manager or its communication links will not significantly affect local portal activity. The system is suitable for installations with large populations requiring access control at several remote sites scattered over a large area

  10. Interactive video audio system: communication server for INDECT portal

    Science.gov (United States)

    Mikulec, Martin; Voznak, Miroslav; Safarik, Jakub; Partila, Pavol; Rozhon, Jan; Mehic, Miralem

    2014-05-01

    The paper deals with presentation of the IVAS system within the 7FP EU INDECT project. The INDECT project aims at developing the tools for enhancing the security of citizens and protecting the confidentiality of recorded and stored information. It is a part of the Seventh Framework Programme of European Union. We participate in INDECT portal and the Interactive Video Audio System (IVAS). This IVAS system provides a communication gateway between police officers working in dispatching centre and police officers in terrain. The officers in dispatching centre have capabilities to obtain information about all online police officers in terrain, they can command officers in terrain via text messages, voice or video calls and they are able to manage multimedia files from CCTV cameras or other sources, which can be interesting for officers in terrain. The police officers in terrain are equipped by smartphones or tablets. Besides common communication, they can reach pictures or videos sent by commander in office and they can respond to the command via text or multimedia messages taken by their devices. Our IVAS system is unique because we are developing it according to the special requirements from the Police of the Czech Republic. The IVAS communication system is designed to use modern Voice over Internet Protocol (VoIP) services. The whole solution is based on open source software including linux and android operating systems. The technical details of our solution are presented in the paper.

  11. Case studies in geographic information systems for internet portals

    Science.gov (United States)

    2012-06-30

    The following report investigates the experiences of transportation agencies in the deployment of Internet-based mapping portals based on GIS. It presents background information, a series of case studies, and a summary of conclusions given the experi...

  12. Cosmological Final Focus Systems

    International Nuclear Information System (INIS)

    Irwin, J

    2004-01-01

    We develop the many striking parallels between the dynamics of light streams from distant galaxies and particle beams in accelerator final focus systems. Notably the deflections of light by mass clumps are identical to the kicks arising from the long-range beam-beam interactions of two counter-rotating particle beams (known as parasitic crossings). These deflections have sextupolar as well as quadrupolar components. We estimate the strength of such distortions for a variety of circumstances and argue that the sextupolar distortions from clumping within clusters may be observable. This possibility is enhanced by the facts that (1) the sextupolar distortions of background galaxies is a factor of 5 smaller than the quadrupolar distortion, (2) the angular orientation of the sextupolar and quadrupolar distortions from a mass distribution would be correlated, appearing as a slightly curved image, (3) these effects should be spatially clumped on the sky

  13. An integrated healthcare enterprise information portal and healthcare information system framework.

    Science.gov (United States)

    Hsieh, S L; Lai, Feipei; Cheng, P H; Chen, J L; Lee, H H; Tsai, W N; Weng, Y C; Hsieh, S H; Hsu, K P; Ko, L F; Yang, T H; Chen, C H

    2006-01-01

    The paper presents an integrated, distributed Healthcare Enterprise Information Portal (HEIP) and Hospital Information Systems (HIS) framework over wireless/wired infrastructure at National Taiwan University Hospital (NTUH). A single sign-on solution for the hospital customer relationship management (CRM) in HEIP has been established. The outcomes of the newly developed Outpatient Information Systems (OIS) in HIS are discussed. The future HEIP blueprints with CRM oriented features: e-Learning, Remote Consultation and Diagnosis (RCD), as well as on-Line Vaccination Services are addressed. Finally, the integrated HEIP and HIS architectures based on the middleware technologies are proposed along with the feasible approaches. The preliminary performance of multi-media, time-based data exchanges over the wireless HEIP side is collected to evaluate the efficiency of the architecture.

  14. MyWelch: building an information portal system in a medical library environment.

    Science.gov (United States)

    Zhang, Dongming; Zambrowicz, Caroline; Zhou, Hong; Roderer, Nancy

    2003-01-01

    MyWelch is a medical library portal system that users can use to create customized web sites that reflect their research needs and personal interests. In the MyWelch environment, faculty and students are empowered to take a greater role in identifying their needs and determining their requirements in the electronic environment. The portal system also facilitates interaction among library users and staff.

  15. A Science Portal and Archive for Extragalactic Globular Cluster Systems Data

    Science.gov (United States)

    Young, Michael; Rhode, Katherine L.; Gopu, Arvind

    2015-01-01

    For several years we have been carrying out a wide-field imaging survey of the globular cluster populations of a sample of giant spiral, S0, and elliptical galaxies with distances of ~10-30 Mpc. We use mosaic CCD cameras on the WIYN 3.5-m and Kitt Peak 4-m telescopes to acquire deep BVR imaging of each galaxy and then analyze the data to derive global properties of the globular cluster system. In addition to measuring the total numbers, specific frequencies, spatial distributions, and color distributions for the globular cluster populations, we have produced deep, high-quality images and lists of tens to thousands of globular cluster candidates for the ~40 galaxies included in the survey.With the survey nearing completion, we have been exploring how to efficiently disseminate not only the overall results, but also all of the relevant data products, to the astronomical community. Here we present our solution: a scientific portal and archive for extragalactic globular cluster systems data. With a modern and intuitive web interface built on the same framework as the WIYN One Degree Imager Portal, Pipeline, and Archive (ODI-PPA), our system will provide public access to the survey results and the final stacked mosaic images of the target galaxies. In addition, the astrometric and photometric data for thousands of identified globular cluster candidates, as well as for all point sources detected in each field, will be indexed and searchable. Where available, spectroscopic follow-up data will be paired with the candidates. Advanced imaging tools will enable users to overlay the cluster candidates and other sources on the mosaic images within the web interface, while metadata charting tools will allow users to rapidly and seamlessly plot the survey results for each galaxy and the data for hundreds of thousands of individual sources. Finally, we will appeal to other researchers with similar data products and work toward making our portal a central repository for data

  16. ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging

    Directory of Open Access Journals (Sweden)

    Pantelis A. Asvestas

    2007-01-01

    Full Text Available The purpose of the paper is to present and evaluate the performance of a new software-based registration system for patient setup verification, during radiotherapy, using electronic portal images. The estimation of setup errors, using the proposed system, can be accomplished by means of two alternate registration methods. (a The portal image of the current fraction of the treatment is registered directly with the reference image (digitally reconstructed radiograph (DRR or simulator image using a modified manual technique. (b The portal image of the current fraction of the treatment is registered with the portal image of the first fraction of the treatment (reference portal image by applying a nearly automated technique based on self-organizing maps, whereas the reference portal has already been registered with a DRR or a simulator image. The proposed system was tested on phantom data and on data from six patients. The root mean square error (RMSE of the setup estimates was 0.8±0.3 (mean value ± standard deviation for the phantom data and 0.3±0.3 for the patient data, respectively, by applying the two methodologies. Furthermore, statistical analysis by means of the Wilcoxon nonparametric signed test showed that the results that were obtained by the two methods did not differ significantly (P value >0.05.

  17. New Technology and Experimental Study on Snow-Melting Heated Pavement System in Tunnel Portal

    Directory of Open Access Journals (Sweden)

    Jinxing Lai

    2015-01-01

    Full Text Available In recent years, with the rapid growth of economy and sharp rise of motor vehicles in China, the pavement skid resistance in tunnel portals has become increasingly important in cold region. However, the deicing salt, snow removal with machine, and other antiskid measures adopted by highway maintenance division have many limitations. To improve the treatment effect, we proposed a new snow-melting approach employing electric heat tracing, in which heating cables are installed in the structural layer of road. Through the field experiment, laboratory experiment, and numerical investigation, structure type, heating power, and preheating time of the flexible pavement heating system in tunnel portal were systematically analyzed, and advantages of electric heat tracing technology in improving the pavement skid resistance in tunnel portal were also presented. Therefore, such new technology, which offers new snow-melting methods for tunnel portal, bridge, mountainous area, and large longitudinal slope in cold region, has promising prospect for extensive application.

  18. Portal manga

    OpenAIRE

    Temprano Hernandez, Joan

    2011-01-01

    El projecte Portal Manga pretén construir una aplicació web que ha de permetre a una empresa anunciar els seus productes a la web, disposar de una botiga virtual en la que es puguin adquirir aquests productes en format digital i finalment un lector web que en permeti la lectura online.

  19. The Gulf of Mexico Coastal Ocean Observing System: A Gulf Science Portal

    Science.gov (United States)

    Howard, M.; Gayanilo, F.; Kobara, S.; Jochens, A. E.

    2013-12-01

    The Gulf of Mexico Coastal Ocean Observing System's (GCOOS) regional science portal (gcoos.org) was designed to aggregate data and model output from distributed providers and to offer these, and derived products, through a single access point in standardized ways to a diverse set of users. The portal evolved under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) program where automated largely-unattended machine-to-machine interoperability has always been a guiding tenet for system design. The web portal has a business unit where membership lists, new items, and reference materials are kept, a data portal where near real-time and historical data are held and served, and a products portal where data are fused into products tailored for specific or general stakeholder groups. The staff includes a system architect who built and maintains the data portal, a GIS expert who built and maintains the current product portal, the executive director who marshals resources to keep news items fresh and data manger who manages most of this. The business portal is built using WordPress which was selected because it appeared to be the easiest content management system for non-web programmers to add content to, maintain and enhance. The data portal is custom built and uses database, PHP, and web services based on Open Geospatial Consortium standards-based Sensor Observation Service (SOS) with Observations and Measurements (O&M) encodings. We employ a standards-based vocabulary, which we helped develop, which is registered at the Marine Metadata Interoperability Ontology Registry and Repository (http://mmisw.org). The registry is currently maintained by one of the authors. Products appearing in the products portal are primarily constructed using ESRI software by a Ph.D. level Geographer. Some products were built with other software, generally by graduate students over the years. We have been sensitive to the private sector when deciding which products to produce. While

  20. The SNS/HFIR Web Portal System for SANS

    International Nuclear Information System (INIS)

    Campbell, Stuart I; Miller, Stephen D; Bilheux, Jean-Christophe; Reuter, Michael A; Peterson, Peter F; Kohl, James A; Trater, James R; Vazhkudai, Sudharshan S; Lynch, Vickie E; Green, Mark L

    2010-01-01

    The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops. The data sizes are too big and the computational time would be too long. These large datasets can be problematic as facility users now begin to struggle with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration with others. The Neutron Science Portal has been designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern computer security requirements that are currently being imposed on institutions. Users can browse or search for data which they are allowed to see, run data reduction and analysis applications, perform sample activation calculations and perform McStas simulations. Collaboration is facilitated by providing users a read/writeable common area, shared across all experiment team members. The portal currently has over 370 registered users; almost 7TB of experiment and user data, approximately 1,000,000 files cataloged, and had almost 10,000 unique visits last year. Future directions for enhancing portal robustness include examining how to mirror data and portal services, better facilitation of collaborations via virtual organizations, enhancing disconnected service via 'thick client' applications, and better inter-facility connectivity to support cross-cutting research.

  1. Estimation of portal-systemic shunting by rectal infusion of radiotracer

    International Nuclear Information System (INIS)

    Piga, M.; Satta, L.; Loviselli, A.; Taglieri, G.; Balestrieri, A.; Cossu, L.; Madeddu, G.

    1986-01-01

    Spontaneous portal anastomoses develop as a consequence of an increased portal pressure gradient. This report presents a new method for evaluating portal-systemic shunts by rectal infusion of a radiotracer. Five patients affected by primary haemorrhoidal syndrome, 15 with chronic liver disease (CLD), 40 with liver cirrhosis (C), 4 with surgical portal anastomoses (PCA) and 9 healty controls were studied. All patients underwent oesophagogastroscopy and 12 wedged hepatic vein pressure determination. After rectal infusion of 99m TcO 4 - by a microclister, scintigraphic images were recorded at the acquisition rate of 1 per 20 seconds for 10 minutes. Two regions of interest, corresponding to the heart (H) and the liver (L), were traced on the display images and the H/L activity ratio a the 4th minute was determined. In controls, the mean H/L ratio was 0.61±0.09, in CLD 0.76±0.18, in C 1.79±0.31 and in PCA 2.00±0.14. Differences between control H/L ratios and those of the groups of patients were statistically significant (p<0.025, 0.0005 and 0.005, respectively). Significant correlations between H/L ratio and wedged hepatic vein pressure (r=-0.61; p<0.001) were found. This rapid, noninvasive procedure, well tolerated by patients, seems to be suitable for the evaluation of portal haemodynamics and for the prediction of portal pressure values

  2. Diagnosis of hepatic encephalopathy with magentic resonance imaging; With special reference to portal system encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Etsuo; Narumi, Yoshifumi; Kadota, Tsuyoshi; Fujita, Makoto; Kuriyama, Keiko; Kuroda, Chikazumi (Osaka Prefectural Center for Adult Diseases (Japan))

    1993-01-01

    Cranial magnetic resonance (MR) images were examined in 16 patients with liver cirrhosis. The findings of MR imaging were correlated with portal-systemic collateral vessel shown on angiograms. In 9 of 16 patients, basal ganglia was hyperintense compared with white matter on T1-weighted images. These 9 patients had portal-systemic collateral vessel 10 mm or more in diameter that was suppied by superior mesenteric vein (SMV), and 4 of the 9 patients had portal-systemic encephalopathy on angiograms. In the remaining 7 patients, no hyperintense lesions were seen in basal ganglia relative to white matter on T1-weighted images; angiography revealed that 2 patients had portal-systemic collateral vessel that was supplied by SMV but was 5 mm or less in diameter, 3 had bood supplies from splenic vein, and 2 had no collateral vessel. There was no change in signal intensity on T2-weighted images. In conclusion, a large portal-systemic collateral vessel supplied by SMV may be shown as a high intensity lesion in basal ganglia, thus making it possible to diagnose hepatic encephalopathy even if there was no psychoneurologic symptoms or signs. (N.K.).

  3. The DIAS/CEOS Water Portal, distributed system using brokering architecture

    Science.gov (United States)

    Miura, Satoko; Sekioka, Shinichi; Kuroiwa, Kaori; Kudo, Yoshiyuki

    2015-04-01

    The DIAS/CEOS Water Portal is a one of the DIAS (Data Integration and Analysis System, http://www.editoria.u-tokyo.ac.jp/projects/dias/?locale=en_US) systems for data distribution for users including, but not limited to, scientists, decision makers and officers like river administrators. This portal has two main functions; one is to search and access data and the other is to register and share use cases which use datasets provided via this portal. This presentation focuses on the first function, to search and access data. The Portal system is distributed in the sense that, while the portal system is located in Tokyo, the data is located in archive centers which are globally distributed. For example, some in-situ data is archived at the National Center for Atmospheric Research (NCAR) Earth Observing Laboratory in Boulder, Colorado, USA. The NWP station time series and global gridded model output data is archived at the Max Planck Institute for Meteorology (MPIM) in cooperation with the World Data Center for Climate in Hamburg, Germany. Part of satellite data is archived at DIAS storage at the University of Tokyo, Japan. This portal itself does not store data. Instead, according to requests made by users on the web page, it retrieves data from distributed data centers on-the-fly and lets them download and see rendered images/plots. Although some data centers have unique meta data format and/or data search protocols, our portal's brokering function enables users to search across various data centers at one time, like one-stop shopping. And this portal is also connected to other data brokering systems, including GEOSS DAB (Discovery and Access Broker). As a result, users can search over thousands of datasets, millions of files at one time. Our system mainly relies on the open source software GI-cat (http://essi-lab.eu/do/view/GIcat), Opensearch protocol and OPeNDAP protocol to enable the above functions. Details on how it works will be introduced during the

  4. Study of streamline flow in the portal system

    International Nuclear Information System (INIS)

    Atkins, H.L.; Deitch, J.S.; Oster, Z.H.; Perkes, E.A.

    1985-01-01

    The study was undertaken to determine if streamline flow occurs in the portal vein, thus separating inflow from the superior mesenteric artery (SMA) and the inferior mesenteric artery. Previously published data on this subject is inconsistent. Patients undergoing abdominal angiography received two administrations of Tc-99m sulfur colloid, first via the SMA during angiography and, after completion of the angiographic procedure, via a peripheral vein (IV). Anterior images of the liver were recorded over a three minute acquisition before and after the IV injection without moving the patient. The image from the SMA injection was subtracted from the SMA and IV image to provide a pure IV image. Analysis of R to L ratios for selected regions of interest as well as whole lobes was carried out and the shift of R to L (SMA to IV) determined. Six patients had liver metastases from the colon, four had cirrhosis and four had no known liver disease. The shift in the ratio was highly variable without a consistent pattern. Large changes in some patients could be attributed to hepatic artery flow directed to metastases. No consistent evidence for streamlining of portal flow was discerned

  5. Further substantial improvement of interventional diagnosis and treatment via portal vein system

    International Nuclear Information System (INIS)

    Yang Weizhu; Chen Yongde

    2006-01-01

    Along with the development of interventional appliances and proficiency of operational skills, the interventional diagnosis and treatment via hepatic portal vein system have achieved great progress and improvement. However, in order to further exploit the advantages of interventional diagnosis and treatment, the review of the anatomical structures, normal aberrance of portal venous system were needed. Getting familiar with pathologic condition to discover the new interventional appliances and embolic agents, and then in term of conduct the research on a very tough substantial base in a down-to-earth manner were important. (authors)

  6. Iron oxide contrast media improve MR-imaging of the portal venous system -an experimental study

    International Nuclear Information System (INIS)

    Boeck, J.C.; Knollmann, F.D.; Teltenkoetter, S.; Wlodarcyk, W.; Muehler, A.; Felix, R.

    1997-01-01

    Purpose: The aim was to demonstrate that intravenous superparamagnetic iron oxide contrast agents improve the delineation of the portal venous system. Material and methods: The portal venous system of 8 minipigs was demonstrated by a FLASH 2-D MRA-sequence. Scans were acquired before and after intravenous administration of 10 and 20 μmol/kg of a superparamagnetic iron oxide contrast agent (SHU 555 A). Signal intensities were measured in the portal vein and hepatic parenchym and contrast-to-noise ratios were calculated. Results: Following a cumulative dose of 10 μmol iron oxide, hepatic parenchymal signal intensity decreased to 67±6%, following 20 μmol to 29±4%, and following 40 μmol to 13±2% of control (p [de

  7. Role of the renin-angiotensin system in hepatic fibrosis and portal hypertension.

    Science.gov (United States)

    Shim, Kwang Yong; Eom, Young Woo; Kim, Moon Young; Kang, Seong Hee; Baik, Soon Koo

    2018-05-01

    The renin-angiotensin system (RAS) is an important regulator of cirrhosis and portal hypertension. As hepatic fibrosis progresses, levels of the RAS components angiotensin (Ang) II, Ang-(1-7), angiotensin-converting enzyme (ACE), and Ang II type 1 receptor (AT1R) are increased. The primary effector Ang II regulates vasoconstriction, sodium homoeostasis, fibrosis, cell proliferation, and inflammation in various diseases, including liver cirrhosis, through the ACE/Ang II/AT1R axis in the classical RAS. The ACE2/Ang-(1-7)/Mas receptor and ACE2/Ang-(1-9)/AT2R axes make up the alternative RAS and promote vasodilation, antigrowth, proapoptotic, and anti-inflammatory effects; thus, countering the effects of the classical RAS axis to reduce hepatic fibrogenesis and portal hypertension. Patients with portal hypertension have been treated with RAS antagonists such as ACE inhibitors, Ang receptor blockers, and aldosterone antagonists, with very promising hemodynamic results. In this review, we examine the RAS, its roles in hepatic fibrosis and portal hypertension, and current therapeutic approaches based on the use of RAS antagonists in patients with portal hypertension.

  8. Embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy

    International Nuclear Information System (INIS)

    Sakurabayashi, Shin; Sezai, Shuichi; Yamamoto, Yoshihiro; Hirano, Masanori; Oka, Hiroshi

    1997-01-01

    Purpose. To evaluate the efficacy of embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy (CRHE). Methods. Seven cirrhotic patients with CRHE refractory to medical treatment (3 men and 4 women, mean age 66 years) were studied. Five patients had splenorenal shunts, 1 had a gastrorenal shunt, and 1 had an intrahepatic portal vein-hepatic vein shunt. Shunt embolization was performed using stainless steel coils, with a percutaneous transhepatic portal vein approach in 4 patients and a transrenal vein approach in 3 patients. Results. After embolization, the shunt disappeared in 4 patients on either ultrasound pulsed Doppler monitoring or portography. Complications observed in the 7 patients were fever, transient pleural effusion, ascites, and mild esophageal varices. For 3-6 months after embolization, the 4 patients whose shunts disappeared showed minimal or no reappearance of a shunt, and had no recurrence of encephalopathy. The serum ammonia levels decreased and electroencephalograms also improved. One of the 4 patients, who developed mild esophageal varices, required no treatment. Treatment was effective in 3 of the 4 patients (75%) who underwent embolization via a transhepatic portal vein. Conclusion. Transvascular embolization of shunts improved the outcome in 4 of 7 patients. The most effective embolization was achieved via the percutaneous transhepatic portal vein approach

  9. A Bayesian sequential processor approach to spectroscopic portal system decisions

    Energy Technology Data Exchange (ETDEWEB)

    Sale, K; Candy, J; Breitfeller, E; Guidry, B; Manatt, D; Gosnell, T; Chambers, D

    2007-07-31

    The development of faster more reliable techniques to detect radioactive contraband in a portal type scenario is an extremely important problem especially in this era of constant terrorist threats. Towards this goal the development of a model-based, Bayesian sequential data processor for the detection problem is discussed. In the sequential processor each datum (detector energy deposit and pulse arrival time) is used to update the posterior probability distribution over the space of model parameters. The nature of the sequential processor approach is that a detection is produced as soon as it is statistically justified by the data rather than waiting for a fixed counting interval before any analysis is performed. In this paper the Bayesian model-based approach, physics and signal processing models and decision functions are discussed along with the first results of our research.

  10. Final focus system for TLC

    International Nuclear Information System (INIS)

    Oide, K.

    1988-11-01

    A limit of the chromaticity correction for the final focus system of a TeV Linear Collider (TLC) is investigated. As the result, it becomes possible to increase the aperture of the final doublet with a small increase of the horizontal β function. The new optics design uses a final doublet of 0.5 mm half-aperture and 1.4 T pole-tip field. The length of the system is reduced from 400 m to 200 m by several optics changes. Tolerances for various machine errors with this optics are also studied. 5 refs., 7 figs., 2 tabs

  11. Design of microprocessor data acquisition system for pedestrian portal SNM monitor

    International Nuclear Information System (INIS)

    Zhang Wenliang

    2003-01-01

    The paper introduces the hardware structure and composition of data acquisition system for pedestrian portal special nuclear material (SNM) monitor. The hardware and software of single chip microprocessor AT89C52, LCM, keyboard and serial communication interface software are also discussed. (authors)

  12. STEM Engagement with NASA's Solar System Treks Portals for Lunar and Planetary Mapping and Modeling

    Science.gov (United States)

    Law, E. S.; Day, B. H.

    2018-01-01

    This presentation will provide an overview of the uses and capabilities of NASA's Solar System Treks family of online mapping and modeling portals. While also designed to support mission planning and scientific research, this presentation will focus on the Science, Technology, Engineering, and Math (STEM) engagement and public outreach capabilities of these web based suites of data visualization and analysis tools.

  13. A Personalised Information Support System for Searching Portals and E-Resources

    Science.gov (United States)

    Sirisha, B. S.; Jeevan, V. K. J.; Raja Kumar, R. V.; Goswami, A.

    2009-01-01

    Purpose: The purpose of this paper is to describe the development of a personalised information support system to help faculty members to search various portals and e-resources without typing the search terms in different interfaces and to obtain results re-ordered without human intervention. Design/methodology/approach: After a careful survey of…

  14. Presence of air in the hepatic portal system in association with umbilical venous catheter malposition

    Directory of Open Access Journals (Sweden)

    Beatriz Regina Alvares

    2014-01-01

    Full Text Available The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.

  15. Effect of Metoclopramide on Portal Blood Flow in Patients with Liver Cirrhosis: Evaluation by the Pulsed Doppler System

    International Nuclear Information System (INIS)

    Baik, Soon Koo; Lee, Yong Gyu; Hong, Sa Joon; Lee, Seong Wu; Lee, Dong Ki; Kwong, Sang Ok

    1994-01-01

    Metoclopramide is known to lower the intravariceal flow by raising the lower esophageal sphincter pressure and consequently decreases the portal blood flow. So we designed this study to assess the effect of metoclopramide on portal blood flow in cirrhotic patients using pulsed Doppler system. By using pulsed Doppler ultrasound, portal blood velocity, diameter of the portal vein, portal blood flow, blood pressure and pulse rate were measured at 15, 30 and 60 minutes after administration of 20mg metoclopramide in 16cirrhotic patients and compared with the basal values. In order 10 cirrhotic patients, normal saline was administrated, and the above mentioned parameters were measured. Wothin 15 minutes after intravenous administration of 20mg metoclopramide, portal blood velocity and portal blood flow decreased significantly, from 12.45+2.64 to 11.80+2.55cm/sec and from 1006.3+407.1 to 974.4+414.7ml/min, respectively(P<0.05). In placebo group,there was no significant change in measured parameters after administration of normal saline. These results support the hypothesis that metoclopramide significantly decreases the portal blood flow transiently in cirrhotic patients with portal hypertension

  16. New noninvasive method for evaluating portal systemic circulation by Tl-201 chloride per-rectal administration

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Norihisa; Nakajima, Kenichi; Hisada, Kinichi; Aburano, Tamio; Tanaka, Nobuyoshi [Kanazawa Univ. (Japan). School of Medicine

    1982-12-01

    A new method for evaluating portal systemic circulation by /sup 201/Tl per-rectal administration was developed and performed in 65 patients with various liver diseases and in 13 control subjects. In normal control, the liver was visualized on the 0 - 5 minutes' image after /sup 201/Tl administration, while the heart, spleen and lungs were not clearly visualized even on the 20 - 25 minutes' image. In patients with portal hypertension, the liver was not clearly visualized, while activities of other organs, especially the heart became great. As the index of estimating the degrees of portal-to-systemic shunt the heart/liver uptake ratio at 20 min. after administration (H/L ratio) was employed. The H/L ratio in liver cirrhosis was significantly higher than those in normal and chronic hepatitis. The patients with esophageal varices showed a significant higher mean H/L ratio compared to that in cirrhotic patients without esophageal varices. There was also a significant difference in H/L ratio between esophageal varices stages. Since there were many other patients with hepatocellular damage who had high H/L ratios similar to those in liver cirrhosis, the effect that hepatocellular damage has on the liver uptake of /sup 201/Tl is also considered. Our present data suggest that this noninvasive method seems to be useful to evaluate the degrees of portal-to-systemic shunt.

  17. Pure and diluted contrast medium in the evaluation of portal venous system with digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Pozzato, C.; Nessi, R.; Raiteri, R.; Uscenghi, C.; Opocher, E.; Santambrogio, R.

    1990-01-01

    We report the results of intra-arterial digital subtraction angiography (DSA) in 100 patients with portal hypertension. The portal venous system was evaluated; all patients underwent angiography of the celiac and superior mesenteric arteries before surgery. Forty-four of them were also examined after Warren splenorenal shunts. Therefore, a total of 144 exams was evaluated. The authors always employed low-osmolality ionic and non-ionic contrast media (iodine concentration: 300-350 mg/ml). In 70 cases pure contrast medium was injected (20/25 ml): in the extant 74 cases it was diluted with an equal volume of saline solution (osmolality and iodine concentration reduced by 50%). Intra-arterial DSA always visualized portal venous system, collateral circulation, shunt location and postoperative changes. The mayor advantage of intra-arterial DSA is the smaller amount of contrast medium injected, so that local and systemic side effects are rare. According to our experience, it is best to dilute the contrast medium and inject the same amount as in conventional angiography, at the same rate. Other well-known advantages of intra-arterial DSA are quicker execution, less injury to arteries using smaller caliber catheters, and low cost. The major disadvantage of intra-arterial DSA, as it appeared also in our study, is the field size of the intensifier, which in our case was limited to 6-9 inches. This is an insufficient coverage for the whole portal system to be studied, and some contrast medium injections become therefore necessary. An average of 3 injections were given to each patient. This problem reduces the advantage of less contrast medium per injection. At any rate, even though intra-arterial DSA exhibits this limitation, it can nevertheless yield important information in the pre- and postoperative evaluation of patients with portal hypertension

  18. Portal Hypertension

    Science.gov (United States)

    ... Overview of Gallbladder Cancer Additional Content Medical News Portal Hypertension By Steven K. Herrine, MD, Professor of Medicine, ... Liver Hepatic Encephalopathy Jaundice in Adults Liver Failure Portal Hypertension Portal hypertension is abnormally high blood pressure in ...

  19. Systemic thrombolysis of portal vein thrombosis in cirrhotic patients: a pilot study.

    Science.gov (United States)

    De Santis, Adriano; Moscatelli, Rosanna; Catalano, Carlo; Iannetti, Antonio; Gigliotti, Francesca; Cristofari, Francesca; Trapani, Silvia; Attili, Adolfo F

    2010-06-01

    Portal vein thrombosis is a frequent complication in liver cirrhosis. Encouraging reports of systemic thrombolysis in non-cirrhotic patients suffering from acute portal vein thrombosis led us to start a pilot study on the efficacy and safety of systemic low dose recombinant tissue plasminogen activator (Actilyse, Boheringer Ingelheim, Florence, Italy). Nine cirrhotic patients (6 males and 3 females) with recent portal vein thrombosis were enrolled. Exclusion criteria were portal cavernomatosis, recent (30 days) surgery, active bleeding, hepatocellular carcinoma and cancer in other sites. All cases were treated for a maximum of 7 days by continuous i.v. infusion of 0.25mg/kg/die of r-tPA plus subcutaneous low molecular weight heparin. Efficacy was evaluated by colour doppler sonography monitoring and confirmed by contrast enhanced computerized tomography. The combined r-tPA/LMWH treatment was well tolerated without clinically significant side effects. Complete resolution of thrombosis occurred in 4 cases, partial regression in 4 and none in 1. Retreatment of a complete recurrence in 1 patient was successful. Variceal pressure dropped from 30.7+/-4.5 mmHg to 21.2+/-6.6 mmHg (p=0.012). Our preliminary data demonstrate that thrombolytic treatment of recent portal vein thrombosis with i.v. r-tPA and LMWH in patients with cirrhosis appears to be safe and effective and can significantly reduce pressure in oesophageal varices. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  20. The mast cell integrates the splanchnic and systemic inflammatory response in portal hypertension

    Directory of Open Access Journals (Sweden)

    Arias Jorge-Luis

    2007-09-01

    Full Text Available Abstract Portal hypertension is a clinical syndrome that is difficult to study in an isolated manner since it is always associated with a greater or lesser degree of liver functional impairment. The aim of this review is to integrate the complications related to chronic liver disease by using both, the array of mast cell functions and mediators, since they possibly are involved in the pathophysiological mechanisms of these complications. The portal vein ligated rat is the experimental model most widely used to study this syndrome and it has been considered that a systemic inflammatory response is produced. This response is mediated among other inflammatory cells by mast cells and it evolves in three linked pathological functional systems. The nervous functional system presents ischemia-reperfusion and edema (oxidative stress and would be responsible for hyperdynamic circulation; the immune functional system causes tissue infiltration by inflammatory cells, particularly mast cells and bacteria (enzymatic stress and the endocrine functional system presents endothelial proliferation (antioxidative and antienzymatic stress and angiogenesis. Mast cells could develop a key role in the expression of these three phenotypes because their mediators have the ability to produce all the aforementioned alterations, both at the splanchnic level (portal hypertensive enteropathy, mesenteric adenitis, liver steatosis and the systemic level (portal hypertensive encephalopathy. This hypothetical splanchnic and systemic inflammatory response would be aggravated during the progression of the chronic liver disease, since the antioxidant ability of the body decreases. Thus, a critical state is produced, in which the appearance of noxious factors would favor the development of a dedifferentiation process protagonized by the nervous functional system. This system rapidly induces an ischemia-reperfusion phenotype with hydration and salinization of the body (hepatorenal

  1. Solar System Treks: Interactive Web Portals or STEM, Exploration and Beyond

    Science.gov (United States)

    Law, E.; Day, B. H.; Viotti, M.

    2017-12-01

    NASA's Solar System Treks project produces a suite of online visualization and analysis tools for lunar and planetary mapping and modeling. These portals offer great benefits for education and public outreach, providing access to data from a wide range of instruments aboard a variety of past and current missions. As a component of NASA's STEM Activation Infrastructure, they are available as resources for NASA STEM programs, and to the greater STEM community. As new missions are planned to a variety of planetary bodies, these tools facilitate public understanding of the missions and engage the public in the process of identifying and selecting where these missions will land. There are currently three web portals in the program: Moon Trek (https://moontrek.jpl.nasa.gov), Mars Trek (https://marstrek.jpl.nasa.gov), and Vesta Trek (https://vestatrek.jpl.nasa.gov). A new release of Mars Trek includes new tools and data products focusing on human landing site selection. Backed by evidence-based cognitive and computer science findings, an additional version is available for educational and public audiences in support of earning along novice-to-expert pathways, enabling authentic, real-world interaction with planetary data. Portals for additional planetary bodies are planned. As web-based toolsets, the portals do not require users to purchase or install any software beyond current web browsers. The portals provide analysis tools for measurement and study of planetary terrain. They allow data to be layered and adjusted to optimize visualization. Visualizations are easily stored and shared. The portals provide 3D visualization and give users the ability to mark terrain for generation of STL/OBJ files that can be directed to 3D printers. Such 3D prints are valuable tools in museums, public exhibits, and classrooms - especially for the visually impaired. The program supports additional clients, web services, and APIs facilitating dissemination of planetary data to external

  2. IMPLEMENTASI DIGITAL ASSET MANAGEMENT SYSTEM PADA WEB PORTAL KARYA SISWA JURUSAN MULTIMEDIA DI SMK NEGERI 1 MARTAPURA

    Directory of Open Access Journals (Sweden)

    Rahmat Ramadhani

    2016-04-01

    Full Text Available Student Works Web Portal Of Multimedia Department In Smk Negeri 1 Martapura is a web portal implementing Digital Asset Management System. This web portal built based by the works of the students who had only used the DVD, in which each store one of his students in a single DVD. This causes problems especially in the limited physical storage space and search work takes a long time. With the waterfall method, built a student works web portal to save the works of the students in the form of digital media. A DAM system is built on a central repository that facilitates the storage, organization, retrieval, use and reuse of digital files. The results of the construction of the web portal is known that there is a significant speed difference between the old system to the new system, the new system can be said to be faster than the old system. In addition, the new system can be seen consuming less physical space than the old system. Based on research conducted, it can be concluded that by implementing the DAM system, the search speed for work can be improved and storage of work can be saved. Keywords: Web Portal, Work, Multimedia, Digital Asset Management, Digital Media. Web Portal Karya Siswa Jurusan Multimedia SMK Negeri 1 Martapura merupakan web portal yang menerapkan Digital Asset Management System. Web portal yang dibangun dilatar belakangi oleh penyimpanan data karya-karya para siswa yang selama ini hanya menggunakan DVD, dimana setiap siswa menyimpan satu karyanya dalam satu DVD. Hal ini menyebabkan masalah terutama pada terbatasnya ruang penyimpanan secara fisik serta pencarian karya yang memerlukan waktu lama. Dengan metode waterfall, dibangunlah sebuah web portal karya siswa yang secara spesifik menyimpan karya-karya para siswa dalam bentuk media digital. Sebuah sistem DAM dibangun di atas repositori pusat yang memfasilitasi penyimpanan, organisasi, pengambilan, pemanfaatan dan penggunaan kembali file digital. Hasil dari dibangunnya web portal

  3. 4D flow MR imaging of the portal venous system: a feasibility study in children

    Energy Technology Data Exchange (ETDEWEB)

    Parekh, Keyur; Rose, Michael; Popescu, Andrada; Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); McCormick School of Engineering, Northwestern University, Department of Biomedical Engineering, Chicago, IL (United States); Schnell, Susanne [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States)

    2017-02-15

    To determine the feasibility of 4D flow MRI for visualization and quantification of the portal venous haemodynamics in children and young adults. 4D flow was performed in 28 paediatric patients (median age, 8.5 years; interquartile range, 5.2-16.5), 15 with non-operated native portal system and 13 with surgically created portal shunt. Image quality assessment for 3D flow visualization and flow pattern analyses was performed. Regional 4D flow peak velocity and net flow were compared with 2D-cine phase contrast MRI (2D-PC MR) in the post-surgical patients. Mean 3D flow visualization quality score was excellent (mean ± SD, 4.2 ± 0.9) with good inter-rater agreement (κ,0.67). Image quality in children aged >10 years was better than children ≤10 years (p < 0.05). Flow pattern was defined for portal, superior mesenteric, splenic veins and splenic artery in all patients. 4D flow and 2D-PC MR peak velocity and net flow were similar with good correlation (peak velocity: 4D flow 22.2 ± 9.1 cm/s and 2D-PC MR 25.2 ± 11.2 cm/s, p = 0.46; r = 0.92, p < 0.0001; net flow: 4D flow 9.5 ± 7.4 ml/s and 2D-PC MR 10.1 ± 7.3 ml/s, p = 0.65; r = 0.81, p = 0.0007). 4D flow MRI is feasible and holds promise for the comprehensive 3D visualization and quantification of portal venous flow dynamics in children and young adults. (orig.)

  4. 4D flow MR imaging of the portal venous system: a feasibility study in children

    International Nuclear Information System (INIS)

    Parekh, Keyur; Rose, Michael; Popescu, Andrada; Rigsby, Cynthia K.; Markl, Michael; Schnell, Susanne

    2017-01-01

    To determine the feasibility of 4D flow MRI for visualization and quantification of the portal venous haemodynamics in children and young adults. 4D flow was performed in 28 paediatric patients (median age, 8.5 years; interquartile range, 5.2-16.5), 15 with non-operated native portal system and 13 with surgically created portal shunt. Image quality assessment for 3D flow visualization and flow pattern analyses was performed. Regional 4D flow peak velocity and net flow were compared with 2D-cine phase contrast MRI (2D-PC MR) in the post-surgical patients. Mean 3D flow visualization quality score was excellent (mean ± SD, 4.2 ± 0.9) with good inter-rater agreement (κ,0.67). Image quality in children aged >10 years was better than children ≤10 years (p < 0.05). Flow pattern was defined for portal, superior mesenteric, splenic veins and splenic artery in all patients. 4D flow and 2D-PC MR peak velocity and net flow were similar with good correlation (peak velocity: 4D flow 22.2 ± 9.1 cm/s and 2D-PC MR 25.2 ± 11.2 cm/s, p = 0.46; r = 0.92, p < 0.0001; net flow: 4D flow 9.5 ± 7.4 ml/s and 2D-PC MR 10.1 ± 7.3 ml/s, p = 0.65; r = 0.81, p = 0.0007). 4D flow MRI is feasible and holds promise for the comprehensive 3D visualization and quantification of portal venous flow dynamics in children and young adults. (orig.)

  5. Clinical applications of a high speed matrix ionization chamber portal imaging system

    International Nuclear Information System (INIS)

    Herk, M. van; Gilhuijs, K.; Dalen, A. van; Ven, P. van de; Fencl, W.

    1995-01-01

    A main disadvantage of the present matrix ionization chamber system for electronic portal imaging is its relatively slow image acquisition of 6 s at full resolution. We have solved this problem by modifying the read-out electronics in two ways: First, faster high voltage switches are applied which work with a higher voltage; Second, faster read-out amplifiers are applied which have reduced cross-talk. With these improvements circuit noise is no longer dominant at typical radiotherapy dose rates. Because the quantum noise level in the matrix ionization chamber system is purely determined by signal integration in the liquid medium, the image scan can now be reduced to as short as 0.55 s with little loss of image quality. However, there is some loss of resolution at readout speed faster than 1.5 s due to speed limitations of the read-out amplifiers. One of the applications of the new device is double exposures for larynx fields. At a reduced dose rate of 125 MU/min, only about 5 MUs are required for a single frame on a 4 MV ABB Dynaray accelerator. Other applications which benefit from the reduced image scan time are time lapse movies. Typically 15 frames per field are made during one fraction. The movies offer both information on patient motion and improved image quality by averaging the frames. Finally, on-line analysis of the images can be performed more easily and has been included in the software package. In can be concluded that the higher speed of the new matrix ionization chamber system is an important improvement for several clinical applications

  6. Theoretical analysis and experimental evaluation of a CsI(Tl) based electronic portal imaging system

    International Nuclear Information System (INIS)

    Sawant, Amit; Zeman, Herbert; Samant, Sanjiv; Lovhoiden, Gunnar; Weinberg, Brent; DiBianca, Frank

    2002-01-01

    This article discusses the design and analysis of a portal imaging system based on a thick transparent scintillator. A theoretical analysis using Monte Carlo simulation was performed to calculate the x-ray quantum detection efficiency (QDE), signal to noise ratio (SNR) and the zero frequency detective quantum efficiency [DQE(0)] of the system. A prototype electronic portal imaging device (EPID) was built, using a 12.7 mm thick, 20.32 cm diameter, CsI(Tl) scintillator, coupled to a liquid nitrogen cooled CCD TV camera. The system geometry of the prototype EPID was optimized to achieve high spatial resolution. The experimental evaluation of the prototype EPID involved the determination of contrast resolution, depth of focus, light scatter and mirror glare. Images of humanoid and contrast detail phantoms were acquired using the prototype EPID and were compared with those obtained using conventional and high contrast portal film and a commercial EPID. A theoretical analysis was also carried out for a proposed full field of view system using a large area, thinned CCD camera and a 12.7 mm thick CsI(Tl) crystal. Results indicate that this proposed design could achieve DQE(0) levels up to 11%, due to its order of magnitude higher QDE compared to phosphor screen-metal plate based EPID designs, as well as significantly higher light collection compared to conventional TV camera based systems

  7. Effect of hypokinesia and the combined action of gravitational load and hypokinesia on the structure of the hepatic portal system.

    Science.gov (United States)

    Drozdova, A V

    1975-10-01

    General hypokinesia during 1--6 weeks resulted in dilatation of the interlobular veins. sinusoids and central veins. The sequence of alterations corresponded to terms of hypokinesia. After exposure to "gravitation stress--hypokinesia for 1--6 weeks" stagnation in the portal system of the liver was less than after exposure to hypokinesia alone, but unevenness of lumens in the interlobular veins and sinusoids was more pronounced. The foci of the vessel spasm were determined. The signs of stagnation in the system of the portal vein and unevenness of the width of all the links of the portal bed were most pronounced after combination "hypokinesia for 1--6 weeks-- gravitation stress".

  8. Treatment of chronic portal-systemic encephalopathy with lactose in lactase-deficient patients.

    Science.gov (United States)

    Uribe, M; Márquez, M A; García-Ramos, G; Escobedo, V; Murillo, H; Guevara, L; Lisker, R

    1980-12-01

    A controlled cross-over clinical comparison of lactose (50 g twice a day) versus neomycin (3 g/day) plus milk of magnesia, was carried out in ten cirrhotic patients with chronic portal-systemic encephalopathy and documented lactase deficiency. Serial semiquantitative assessments were done including: mental state, asterixis, number connection test, electroencephalogram, and blood ammonia levels. No patient developed deep coma while ingesting either lactose or neomycin plus milk of magnesia. However, a significant improvement of mental state, asterixis, number connection tests, and electroencephalograms was evident during lactose therapy. apart from mild diarrhea and bloating, no severe side effects were noticeable during lactose treatment. Based on these results, we propose lactose as a valuable alternate treatment of portal-systemic encephalopathy in lactase-deficient populations.

  9. Information security threats in web-portals on the open journal systems platform

    Directory of Open Access Journals (Sweden)

    Anton A. Abramov

    2018-05-01

    Full Text Available This article addresses the problem of security threats while working with web portals built on the Open Journal Systems platform. The Open Journal Systems (OJS platform was originally developed as part of the Public Knowledge Project and it is one of the most popular open-source platforms for web journals today. Based on the data available in the Public Knowledge Project, there were more than 10,000 active journals using the open journal systems platform by the end of 2016. A migration of a journal to such advanced and complex platform helps to handle the entire workflow over a single web portal. Therefore it is an important move and only peer-reviewed journals that are part of Russian and Worldwide citation systems go for it. At the same time the problem of keeping privacy for a manuscript before it is published is very important for these journals and for authors who submit it to the journal. The paper describes the most common threats for the web portals on the OJS platform as well as a particular model of the security threats, and suggests the measures that could help to neutralize these threats.

  10. Development of Distributed System for Informational Location and Control on the Corporate Web Portal "Analytical Chemistry in Russia"

    Science.gov (United States)

    Shirokova, V. I.; Kolotov, V. P.; Alenina, M. V.

    A new Internet portal developed by community of Russian analysts has been launched in 2001 (http://www.geokhi.ru/~rusanalytchem, http://www.rusanalytchem.org) Corporate Web Portal information, "Analytical Chemistry in Russia" , Corporate Web Portal information, "Analytical Chemistry in Russia" ). Now the portal contains a large amount of information, great part of it is stored in the form of SQL data base (MS SQL). The information retrieval is made by means of ASP pages, containing VB Scripts. The obtained experience of work with such topical portal has detected some weak points, related with its centralized administration and updating. It has been found that urgent supporting of all requests from different persons/organizations on information allocation on the portal's server takes a lot of efforts and time. That is why, the further development of portal we relate with development of a distributed system for information allocation and control, under preserving of centralized administration for ensuring of security and stable working of the portal. Analysis and testing of some available technologies lead us to conclusion to apply MS Share Point technologies. A MS Share Point Team Services (SPTS) has been selected as a technology supporting relatively small groups, where MS SQL is used for storage data and metadata. The last feature was considered as decisive one for SPTS selection, allowing easy integration with data base of the whole portal. SPTS was launched as an independent Internet site accessible from home page of the portal. It serves as a root site to exit to dozens of subsites serving different bodies of Russian Scientific Council on analytical chemistry and external organizations located over the whole Russia. The secure functioning of such hierarchical system, which includes a lot of remote information suppliers, based on use of roles to manage user rights independently for each subsite. The root site is controlled by portal administrator, whereas the

  11. Knowledge Portal Support to the Naval Postgraduate School's Advanced Distributed Learning Program for the Information Systems and Operations Curriculum

    National Research Council Canada - National Science Library

    Walker, Allisa

    2000-01-01

    .... The goal of this research is to show how developing a knowledge portal for use with the Information Systems and Operations curriculum knowledge base could expand the use of tacit and explicit knowledge by the operators...

  12. Systemic mastocytosis: A rare cause of non-cirrhotic portal hypertension.

    Science.gov (United States)

    Martins, Cláudio; Teixeira, Cristina; Ribeiro, Suzane; Trabulo, Daniel; Cardoso, Cláudia; Mangualde, João; Freire, Ricardo; Gamito, Élia; Alves, Ana Luísa; Cremers, Isabelle; Alves, Cecília; Neves, Anabela; Oliveira, Ana Paula

    2016-07-28

    Mastocytosis is a clonal neoplastic disorder of the mast cells (MC) that can be limited to the skin (cutaneous mastocytosis) or involve one or more extracutaneous organs (systemic mastocytosis). The clinical manifestations of mastocytosis are heterogeneous ranging from indolent disease with a long-term survival to a highly aggressive neoplasm with survival of about 6 mo. Although liver involvement in aggressive systemic mastocytosis (ASM) is relatively common, the development of portal hypertension with or without cirrhosis is rare. We report a case of ASM without skin involvement in a 72-year-old caucasian male who presented with non-cirrhotic portal hypertension based on clinical, analytical, imagiological and endoscopic findings. Given the hematological picture, the correct diagnosis was established based on ancillary tests for MC using bone marrow aspirates and biopsy. Extensive involvement of the liver and gastrointestinal tract was histologically documented. The disease progressed rapidly and severe pancytopenia and recurrent upper gastrointestinal bleeding became the dominant problem. This case illustrates the challenge in establishing a diagnosis of ASM especially when the clinical picture is atypical and without skin involvement. Gastroenterologists should consider infiltrative disease, particularly systemic mastocytosis, as a differential diagnosis in a clinical case of portal hypertension of unknown etiology.

  13. Gamma portal detector with micro-processed and GSM communication system

    International Nuclear Information System (INIS)

    Carneiro, Lindolff Thadeu

    2008-01-01

    Full text: We present in this paper a new concept of gamma radiation portal detector, where the detection process is monitored by a micro-controller, coupled to a compatible GSM communication system, which is suitable to be accessed by all mobile phone operators worldwide. The signal generated at the detectors is converted by an A/D circuit, and driven to a micro-controller where a software evaluates the signal conditions and, depending on a previously set program, it triggers a communication system which sends the alarm to any computer linked to internet and/or to any mobile phone protocol by a specific software linked to the portal. The control electronic system is compatible to several detectors types, ranging from gas based devices to solid state ones. The portal is totally compatible with the ANSI - Standard N42.35 - 2004. It can be used in all types of government and industrial control scenarios. Its measure device permits the use of the equipment in all range of sensibility and in tracking radiation signals where it is. (author)

  14. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    Purpose/Objective: The purpose of this presentation is to review the physics of imaging with high energy x-ray beams; examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine errors in patient positioning quantitatively; and discuss some of the ways that portal imaging has been incorporated into routine clinical practice. Verification of patient positioning has always been an important aspect of external beam radiation therapy. Checks of patient positioning have generally been done with film, however, film suffers from a number of drawbacks, such as poor image display and delays due to film development. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems, which are intended to overcome the limitations of portal films. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The fundamental factors which limit image quality and the characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same

  15. : acquired resistance in mice by implantation of young irradiated worms into the portal system

    Directory of Open Access Journals (Sweden)

    Paulo Marcos Z. Coelho

    1989-02-01

    Full Text Available In two distinct experiments, immature S. mansoni worms (LE strain, Belo Horizonte, Brazil, aged 20 days, obtained from the portal system of white outbred mice, were irradiated with 14 and 4 Krad, respectively. Afterwards, the worms were directly inoculated into the portal vein of normal mice. Inoculation was performed with 20 irradiated worms per animal. Fifty days after inoculation, the mice that received 4 and 14 Krad-irradiated worms and their respective controls were infected with S. mansoni cercariae (LE strain, by transcutaneous route. Twenty days after this challenge infection, the animals were sacrificed and perfused for mature irradiated (90-day-old and immature (20-day-old worm counts. Analysis of the results showed that statistically significant protection against cercariae occurred in both groups with irradiated worms.

  16. Central and systemic haemodynamic effects of terlipressin in portal hypertensive patients

    DEFF Research Database (Denmark)

    Møller, S; Hansen, E F; Becker, U

    2000-01-01

    the acute effects of terlipressin on central and systemic haemodynamics. METHODS: Sixteen patients with alcoholic cirrhosis and portal hypertension had their systemic, central, and splanchnic haemodynamics determined at baseline and after a blind randomised bolus infusion (2 mg) of terlipressin...... vascular resistance (r=-0.52, pportal hypertensive patients without a further contraction of the central and arterial blood volume. The systemic haemodynamic...... increased by 36% (pportal pressure and hepatic blood flow decreased (17% and 29%, both pportal pressure after terlipressin was significantly related to the increase in systemic...

  17. NASA's Solar System Treks: Online Portals for Planetary Mapping and Modeling

    Science.gov (United States)

    Day, B. H.; Law, E.

    2017-12-01

    NASA's Solar System Treks are a suite of web-based of lunar and planetary mapping and modeling portals providing interactive visualization and analysis tools enabling mission planners, planetary scientists, students, and the general public to access mapped lunar data products from past and current missions for the Moon, Mars, Vesta, and more. New portals for additional planetary bodies are being planned. This presentation will recap significant enhancements to these toolsets during the past year and look ahead to future features and releases. Moon Trek is a new portal replacing its predecessor, the Lunar Mapping and Modeling Portal (LMMP), that significantly upgrades and builds upon the capabilities of LMMP. It features greatly improved navigation, 3D visualization, fly-overs, performance, and reliability. Additional data products and tools continue to be added. These include both generalized products as well as polar data products specifically targeting potential sites for NASA's Resource Prospector mission as well as for missions being planned by NASA's international partners. The latest release of Mars Trek includes new tools and data products requested by NASA's Planetary Science Division to support site selection and analysis for Mars Human Landing Exploration Zone Sites. Also being given very high priority by NASA Headquarters is Mars Trek's use as a means to directly involve the public in upcoming missions, letting them explore the areas the agency is focusing upon, understand what makes these sites so fascinating, follow the selection process, and get caught up in the excitement of exploring Mars. Phobos Trek, the latest effort in the Solar System Treks suite, is being developed in coordination with the International Phobos/Deimos Landing Site Working Group, with landing site selection and analysis for JAXA's MMX mission as a primary driver.

  18. NASA's Solar System Treks: Online Portals for Planetary Mapping and Modeling

    Science.gov (United States)

    Day, Brian

    2017-01-01

    NASA's Solar System Treks are a suite of web-based of lunar and planetary mapping and modeling portals providing interactive visualization and analysis tools enabling mission planners, planetary scientists, students, and the general public to access mapped lunar data products from past and current missions for the Moon, Mars, Vesta, and more. New portals for additional planetary bodies are being planned. This presentation will recap significant enhancements to these toolsets during the past year and look ahead to future features and releases. Moon Trek is a new portal replacing its predecessor, the Lunar Mapping and Modeling Portal (LMMP), that significantly upgrades and builds upon the capabilities of LMMP. It features greatly improved navigation, 3D visualization, fly-overs, performance, and reliability. Additional data products and tools continue to be added. These include both generalized products as well as polar data products specifically targeting potential sites for NASA's Resource Prospector mission as well as for missions being planned by NASA's international partners. The latest release of Mars Trek includes new tools and data products requested by NASA's Planetary Science Division to support site selection and analysis for Mars Human Landing Exploration Zone Sites. Also being given very high priority by NASA Headquarters is Mars Trek's use as a means to directly involve the public in upcoming missions, letting them explore the areas the agency is focusing upon, understand what makes these sites so fascinating, follow the selection process, and get caught up in the excitement of exploring Mars. Phobos Trek, the latest effort in the Solar System Treks suite, is being developed in coordination with the International Phobos/Deimos Landing Site Working Group, with landing site selection and analysis for JAXA's MMX (Martian Moons eXploration) mission as a primary driver.

  19. Extrahepatic portal hypertension in childhood

    International Nuclear Information System (INIS)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-01-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood. (author)

  20. SU-F-J-196: A Prototype System for Portal Imaging for Intensity Modulated Neutron Therapy

    Energy Technology Data Exchange (ETDEWEB)

    St James, S; Argento, D; DeWitt, D; Miyaoka, R; Stewart, R [University of Washington, Seattle, WA (United States); Moffitt, G [University of Utah, Salt Lake City, UT (United States)

    2016-06-15

    Purpose: Fast neutron therapy is offered at the University of Washington Medical Center for treatment of selected cancers. The hardware and control systems of the UW Clinical Neutron Therapy System are undergoing upgrades to enable delivery of IMNT. To clinically implement IMNT, dose verification tools need to be developed. We propose a portal imaging system that relies on the creation of positron emitting isotopes ({sup 11}C and {sup 15}O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects the annihilation photons. The pattern of activity produced in the plate provides information to reconstruct the neutron fluence map that can be compared to fluence maps from Monte Carlo (MCNP) simulations to verify treatment delivery. We have previously performed Monte Carlo simulations of the portal imaging system (GATE simulations) and the beam line (MCNP simulations). In this work, initial measurements using a prototype system are presented. Methods: Custom electronics were developed for BGO detectors read out with photomultiplier tubes (previous generation PET detectors from a CTI ECAT 953 scanner). Two detectors were placed in coincidence, with a detector separation of 2 cm. Custom software was developed to create the crystal look up tables and perform a limited angle planar reconstruction with a stochastic normalization. To test the initial capabilities of the system, PMMA squares were irradiated with neutrons at a depth of 1.5 cm and read out using the prototype system. Doses ranging from 10–200 cGy were delivered. Results: Using the prototype system, dose differences in the therapeutic range could be determined. Conclusion: The prototype portal imaging system is capable of detecting neutron doses as low as 10–50 cGy and shows great promise as a patient QA tool for IMNT.

  1. Effective Prevention for Portal Venous System Thrombosis After Splenectomy: A Meta-Analysis.

    Science.gov (United States)

    Zhang, Xiao; Wang, Yadong; Yu, Miao; Huang, Jinzhao; Deng, Dongfeng; Xue, Huanzhou

    2017-03-01

    Portal venous system thrombosis (PVST) is a common and potentially life-threatening complication of splenectomy for portal hypertension due to cirrhosis. A meta-analysis was conducted to study the necessity of pharmacologic prophylaxis of PVST after splenectomy and how to select the feasible treatment method. Articles were searched through the PubMed, EMBASE, Cochrane Library databases, and CNKI. Overall, 404 articles were initially identified, and 11 of them were eligible. Among these selected articles, 7 articles were associated with the necessity of anticoagulation for prevention of PVST, while 5 were about the drug selection. We first demonstrated that the incidence of PVST after splenectomy was significantly lower in patients who received the preventive measures than in those who did not (odds ratio [OR]: 0.22, 95% confidence interval [CI]: 0.13-0.39, P splenectomy and devascularization. Preventative use of anticoagulant drugs might decrease the incidence of PVST after splenectomy in patients with portal hypertension, new anticoagulant drugs such as low-molecular-weight heparin should be used, and early or combination use of anticoagulation drugs might lead to lower PVST incidence for patients.

  2. Use of NLM medical subject headings with the MeSH2010 thesaurus in the PORTAL-DOORS system.

    Science.gov (United States)

    Taswell, Carl

    2010-01-01

    The NLM MeSH Thesaurus has been incorporated for use in the PORTAL-DOORS System (PDS) for resource metadata management on the semantic web. All 25588 descriptor records from the NLM 2010 MeSH Thesaurus have been exposed as web accessible resources by the PDS MeSH2010 Thesaurus implemented as a PDS PORTAL Registry operating as a RESTful web service. Examples of records from the PDS MeSH2010 PORTAL are demonstrated along with their use by records in other PDS PORTAL Registries that reference the concepts from the MeSH2010 Thesaurus. Use of this important biomedical terminology will greatly enhance the quality of metadata content of other PDS records thus improving cross-domain searches between different problem oriented domains and amongst different clinical specialty fields.

  3. The weight and angle of depression detection and control system of a large portal crane

    Science.gov (United States)

    Shi, Lian-Wen; Xie, Hongxia; Wang, Meijing; Guan, Yankui; Leng, Gengxin

    2008-12-01

    In order to prevent overturning accidents, the lifted weight and the angle of depression should be detected when a large portal crane is working in a shipyard. However, the locations of the weight sensor and the angle of depression detection part are far away from the central control room. The long signal transmitting distance is so long that it results in a lot of interferences, even the breaking down of the system. In order to solve the above mentioned problems, a high precision analog signal amplifier and a voltage / current (V / I) transforming circuit is set at the place of the sensor to detect the weight. After the sensor signals have been amplified, they will be transformed into 4 to 20 mA current signals for transmission. Thus the interferences in the long transmitting process can be overcome. A WXJ-3 potentiometer is applied to detect the angle of depression. This device has the advantages of a high accuracy of repeated positions, a good stability and a strong anti-fatigue property. After processed by the current-strengthened circuit, the transmitted signals representing voltage value can have the characteristics of transmitting currents because of the large current value. Then the anti-jamming capability is stronger. Send the weight and the angle of depression detection signals to A/D converter, then the signals turn into digital representation and are sent to the control system composed of a PLC. The PLC calculates the current rated lifting weight depending on the different angles of depression, and when the weight is greater than the rated one, the PLC sends control signals to stop the lifting; hence the crane can only put down the weights. So the safety of the large portal crane is effectively guaranteed. At present ,the system has been applied to the 70-ton large portal cranes of the Tianjin Xingang Shipyard with a safe operation of 10 years.

  4. Characterization of an electronic system for Image acquisition portal to open field dosimetry; Caracterizacao de um sistema eletronico de aquisicao de imagem portal para dosimetria em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Barbi, Gustavo L.; Oliveira, Harley F.; Bertucci, Edenyse C.; Amaral, Leonardo L.; Borges, Leandro F., E-mail: gustavobarbi@usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Centro de Ciencias das Imagens e Fisica Medica

    2012-08-15

    The objective was to characterize and enable an electronic portal imaging device (EPID) to use like a portal dosimetry device - PDI, in non-transit mode, without interposition of scattering between the beam and EPID for measurement to open fields. The images as well as the DICOM header data are extracted from software ImageJ and the information are used in the basic algorithm for converting pixel to dose. The linearity and reproducibility of response were analyzed, and the maximum deviation found of 2,3% to 800 monitor units (MU) for linearity and -0,9% for reproducibility of signal measured daily. A 512x512 matrix with a resolution of 0,8mm was established to restore the shape of beam from the image. The field size dependence was evaluated, by obtaining the ratio of total scattering of ionization chamber and EPID. Finally, a calibration factor of 28470.88{+-}170.73 pixel/cGy was established for the central area of the image. Comparative analyzes between the PDI, radiochromic film and array of ionization chambers (MatriXX) showed good agreement for fields greater then 5 x 5 cm{sup 2} to reestablishment of form field and dose, however, for fields between 3x3 cm{sup 2} and 5x5 cm{sup 2}, the agreement to shape of beam was best established by film. (author)

  5. Evaluating user experiences of the secure messaging tool on the Veterans Affairs' patient portal system.

    Science.gov (United States)

    Haun, Jolie N; Lind, Jason D; Shimada, Stephanie L; Martin, Tracey L; Gosline, Robert M; Antinori, Nicole; Stewart, Max; Simon, Steven R

    2014-03-06

    The United States Department of Veterans Affairs has implemented an electronic asynchronous "Secure Messaging" tool within a Web-based patient portal (ie, My HealtheVet) to support patient-provider communication. This electronic resource promotes continuous and coordinated patient-centered care, but to date little research has evaluated patients' experiences and preferences for using Secure Messaging. The objectives of this mixed-methods study were to (1) characterize veterans' experiences using Secure Messaging in the My HealtheVet portal over a 3-month period, including system usability, (2) identify barriers to and facilitators of use, and (3) describe strategies to support veterans' use of Secure Messaging. We recruited 33 veterans who had access to and had previously used the portal's Secure Messaging tool. We used a combination of in-depth interviews, face-to-face user-testing, review of transmitted secure messages between veterans and staff, and telephone interviews three months following initial contact. We assessed participants' computer and health literacy during initial and follow-up interviews. We used a content-analysis approach to identify dominant themes in the qualitative data. We compared inferences from each of the data sources (interviews, user-testing, and message review) to identify convergent and divergent data trends. The majority of veterans (27/33, 82%) reported being satisfied with Secure Messaging at initial interview; satisfaction ratings increased to 97% (31/32, 1 missing) during follow-up interviews. Veterans noted Secure Messaging to be useful for communicating with their primary care team to manage health care needs (eg, health-related questions, test requests and results, medication refills and questions, managing appointments). Four domains emerged from interviews: (1) perceived benefits of using Secure Messaging, (2) barriers to using Secure Messaging, (3) facilitators for using Secure Messaging, and (4) suggestions for improving

  6. Implementation of a program of quality assurance of image in an imaging system of flat panel portal

    International Nuclear Information System (INIS)

    Gomez Barrado, A.; Sanchez Jimenez, E.; Benitez, J. A.; Sanchez-Reyes, A.

    2013-01-01

    (IGRT) image-guided radiation therapy is the one in which images are used to locate the area of treatment. Modern irradiation systems are equipped with different modalities for obtaining images, such as flat panel systems, systems conebeam, tomoimagen, etc. This paper describes the start-up and the experience of a quality assurance program based on a flat panel portal Imaging System. (Author)

  7. The SNS/HFIR Web Portal System How Can it Help Me?

    International Nuclear Information System (INIS)

    Miller, Stephen D.; Geist, Al; Herwig, Kenneth W.; Peterson, Peter F.; Reuter, Michael A.; Ren, Shelly; Bilheux, Jean-Christophe; Campbell, Stuart I.; Kohl, James Arthur; Vazhkudai, Sudharshan S.; Cobb, John W.; Lynch, Vickie E.; Chen, Meili; Trater, James R.

    2010-01-01

    In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a live cataloging system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to their

  8. Harmonization of the Spanish radiation protection education and training system: educational specialized portal

    International Nuclear Information System (INIS)

    Marco Arboli, Marisa; Rodriguez Suarez, M.; Villarroel Gonzalez Elipe, R.; Rodriguez Marti, M.

    2008-01-01

    Full text: This paper shows the educational project developed by the Spanish Regulatory Body (CSN) and CIEMAT. The Radiation Protection Training and Education Portal is included in the framework of the regulated training system in Spain. The project is available on the CSN web site 'www.csn.es'. The main objective of this specialized portal is to provide the necessary mechanisms for standardization of the radiation protection knowledge and to provide training tools. One of the priorities of this project is to spread in Latino America the efforts of a big group of professionals made in the past years on education and training. The initiative also aims to collaborate and share resources. The web site is used for delivery of education content. The RP E and T Portal provides training material for course organizers, trainers and professionals involved. The project includes training tools for sixteen courses based in the standard syllabus content in the Spanish regulations. The courses have been prepared in a modular approach with specific modules focused in medical and industrial applications and prepared taking into account the different target groups and common levels. Each one of the modules includes learning objectives, syllabus, training schedule, theoretical lessons and practical sessions guidance, visual aids for trainers and test and questions to be used as self-evaluation. The training packages cover the initial training programmes needed by supervisors and operators of radioactive facilities in different areas of expertise including diagnostic radiology. The tasks in each of the modules have been designed to develop specific competence. More than 40 recognized experts have participated in this useful open project and their contribution to the training material offer important results and based on their experience having special attention on the quality of the material. (author)

  9. ChlamyCyc: an integrative systems biology database and web-portal for Chlamydomonas reinhardtii

    Directory of Open Access Journals (Sweden)

    Kempa Stefan

    2009-05-01

    Full Text Available Abstract Background The unicellular green alga Chlamydomonas reinhardtii is an important eukaryotic model organism for the study of photosynthesis and plant growth. In the era of modern high-throughput technologies there is an imperative need to integrate large-scale data sets from high-throughput experimental techniques using computational methods and database resources to provide comprehensive information about the molecular and cellular organization of a single organism. Results In the framework of the German Systems Biology initiative GoFORSYS, a pathway database and web-portal for Chlamydomonas (ChlamyCyc was established, which currently features about 250 metabolic pathways with associated genes, enzymes, and compound information. ChlamyCyc was assembled using an integrative approach combining the recently published genome sequence, bioinformatics methods, and experimental data from metabolomics and proteomics experiments. We analyzed and integrated a combination of primary and secondary database resources, such as existing genome annotations from JGI, EST collections, orthology information, and MapMan classification. Conclusion ChlamyCyc provides a curated and integrated systems biology repository that will enable and assist in systematic studies of fundamental cellular processes in Chlamydomonas. The ChlamyCyc database and web-portal is freely available under http://chlamycyc.mpimp-golm.mpg.de.

  10. ChlamyCyc: an integrative systems biology database and web-portal for Chlamydomonas reinhardtii.

    Science.gov (United States)

    May, Patrick; Christian, Jan-Ole; Kempa, Stefan; Walther, Dirk

    2009-05-04

    The unicellular green alga Chlamydomonas reinhardtii is an important eukaryotic model organism for the study of photosynthesis and plant growth. In the era of modern high-throughput technologies there is an imperative need to integrate large-scale data sets from high-throughput experimental techniques using computational methods and database resources to provide comprehensive information about the molecular and cellular organization of a single organism. In the framework of the German Systems Biology initiative GoFORSYS, a pathway database and web-portal for Chlamydomonas (ChlamyCyc) was established, which currently features about 250 metabolic pathways with associated genes, enzymes, and compound information. ChlamyCyc was assembled using an integrative approach combining the recently published genome sequence, bioinformatics methods, and experimental data from metabolomics and proteomics experiments. We analyzed and integrated a combination of primary and secondary database resources, such as existing genome annotations from JGI, EST collections, orthology information, and MapMan classification. ChlamyCyc provides a curated and integrated systems biology repository that will enable and assist in systematic studies of fundamental cellular processes in Chlamydomonas. The ChlamyCyc database and web-portal is freely available under http://chlamycyc.mpimp-golm.mpg.de.

  11. Portal verification using the KODAK ACR 2000 RT storage phosphor plate system and EC films. A semiquantitative comparison.

    Science.gov (United States)

    Geyer, Peter; Blank, Hilbert; Alheit, Horst

    2006-03-01

    The suitability of the storage phosphor plate system ACR 2000 RT (Eastman Kodak Corp., Rochester, MN, USA), that is destined for portal verification as well as for portal simulation imaging in radiotherapy, had to be proven by the comparison with a highly sensitive verification film. The comparison included portal verification images of different regions (head and neck, thorax, abdomen, and pelvis) irradiated with 6- and 15-MV photons and electrons. Each portal verification image was done at the storage screen and the EC film as well, using the EC-L cassettes (both: Eastman Kodak Corp., Rochester, MN, USA) for both systems. The soft-tissue and bony contrast and the brightness were evaluated and compared in a ranking of the two compared images. Different phantoms were irradiated to investigate the high- and low-contrast resolution. To account for quality assurance application, the short-time exposure of the unpacked and irradiated storage screen by green and red room lasers was also investigated. In general, the quality of the processed ACR images was slightly higher than that of the films, mostly due to cases of an insufficient exposure to the film. The storage screen was able to verify electron portals even for low electron energies with only minor photon contamination. The laser lines were sharply and clearly visible on the ACR images. The ACR system may replace the film without any noticeable decrease in image quality thereby reducing processing time and saving the costs of films and avoiding incorrect exposures.

  12. Prominent porto-systemic collateral pathways in patients with portal hypertension: demonstration by gadolinium-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Caldana, Rogerio Pedreschi; Bezerra, Alexandre Araujo Sergio; Cecin, Alexnadre Oliveira; Souza, Luis Ronan Marques Ferreira de; Goldman, Susan Menasce; D'Ippolito, Giuseppe; Szejnfeld, Jacob

    2003-01-01

    To demonstrate the usefulness of gadolinium-enhanced magnetic resonance angiography in the evaluation of prominent porto-systemic collateral pathways. We reviewed the images from 40 patients with portal hypertension studied with gadolinium-enhanced magnetic resonance angiography and selected illustrative cases of prominent porto-systemic collateral pathways. The scans were performed using high field equipment (1.5 Tesla) and a 3 D volume technique. Image were obtained after intravenous injection of paramagnetic contrast media using a power injector. Magnetic resonance angiography demonstrated with precision the porto-systemic collateral pathways, particularly when investigating extensive territories or large vessels. The cases presented show the potential of this method in the investigation of patients with portal hypertension. Gadolinium-enhanced magnetic resonance angiography is a useful method for the evaluation of patients with portal hypertension and prominent collateral pathways. (author)

  13. Observation of portal systemic circulation after sclerotherapy and/or splenic embolization studied by Tl-201 per-rectal administration

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Norihisa; Nakajima, Kenichi; Kawabata, Suzuka

    1987-11-01

    Tl-201 per-rectal study was performed to observe the changes of portal systemic shunting after injection sclerotherapy and/or partial splenic embolization in patients with esophageal varices. The changes in the heart to liver uptake ratio of Tl-201 after injection sclerotherapy were widely ranged from the decrease to the increase with a mean change rate of 19 % (mean of the absolute value of change rate). By partial splenic embolization, the heart to liver uptake ratio was decreased significantly with a mean change rate of 26.2 % (p < 0.05). This noninvasive and simple method was found to be sensitive in revealing pathophysiological changes of portal systemic shunting after treatments of portal vein system.

  14. DRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects

    Directory of Open Access Journals (Sweden)

    Fischer Roland

    2017-09-01

    Full Text Available Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.

  15. A Web portal for the Engineering and Equipment Data Management System at CERN

    International Nuclear Information System (INIS)

    Tsyganov, A; Petit, S; Martel, P; Milenkovic, S; Suwalska, A; Delamare, C; Widegren, D; Amerigo, S Mallon; Pettersson, T

    2010-01-01

    CERN, the European Laboratory for Particle Physics, located in Geneva - Switzerland, has recently started the Large Hadron Collider (LHC), a 27 km particle accelerator. The CERN Engineering and Equipment Data Management Service (EDMS) provides support for managing engineering and equipment information throughout the entire lifecycle of a project. Based on several both in-house developed and commercial data management systems, this service supports management and follow-up of different kinds of information throughout the lifecycle of the LHC project: design, manufacturing, installation, commissioning data, maintenance and more. The data collection phase, carried out by specialists, is now being replaced by a phase during which data will be consulted on an extensive basis by non-experts users. In order to address this change, a Web portal for the EDMS has been developed. It brings together in one space all the aspects covered by the EDMS: project and document management, asset tracking and safety follow-up. This paper presents the EDMS Web portal, its dynamic content management and its 'one click' information search engine.

  16. Evaluating User Experiences of the Secure Messaging Tool on the Veterans Affairs’ Patient Portal System

    Science.gov (United States)

    Lind, Jason D; Shimada, Stephanie L; Martin, Tracey L; Gosline, Robert M; Antinori, Nicole; Stewart, Max; Simon, Steven R

    2014-01-01

    Background The United States Department of Veterans Affairs has implemented an electronic asynchronous “Secure Messaging” tool within a Web-based patient portal (ie, My HealtheVet) to support patient-provider communication. This electronic resource promotes continuous and coordinated patient-centered care, but to date little research has evaluated patients’ experiences and preferences for using Secure Messaging. Objective The objectives of this mixed-methods study were to (1) characterize veterans’ experiences using Secure Messaging in the My HealtheVet portal over a 3-month period, including system usability, (2) identify barriers to and facilitators of use, and (3) describe strategies to support veterans’ use of Secure Messaging. Methods We recruited 33 veterans who had access to and had previously used the portal’s Secure Messaging tool. We used a combination of in-depth interviews, face-to-face user-testing, review of transmitted secure messages between veterans and staff, and telephone interviews three months following initial contact. We assessed participants’ computer and health literacy during initial and follow-up interviews. We used a content-analysis approach to identify dominant themes in the qualitative data. We compared inferences from each of the data sources (interviews, user-testing, and message review) to identify convergent and divergent data trends. Results The majority of veterans (27/33, 82%) reported being satisfied with Secure Messaging at initial interview; satisfaction ratings increased to 97% (31/32, 1 missing) during follow-up interviews. Veterans noted Secure Messaging to be useful for communicating with their primary care team to manage health care needs (eg, health-related questions, test requests and results, medication refills and questions, managing appointments). Four domains emerged from interviews: (1) perceived benefits of using Secure Messaging, (2) barriers to using Secure Messaging, (3) facilitators for using

  17. Quality study of portal images acquired by computed radiography and screen-film system under megavoltage ray

    International Nuclear Information System (INIS)

    Cao Guoquan; Jin Xiance; Wu Shixiu; Xie Congying; Zhang Li; Yu Jianyi; Li Yueqing

    2007-01-01

    Objective: To evaluate the quality of the portal images acquired by computed radiography (CR) system and conventional screen-film system, respectively. Methods: Imaging plates (IP) and X-ray films ora home-devised lead phantom with a leakage of 6.45% were acquired, and modulation transfer function (MTF) curves of the both images were measured using edge method. Portal images of 40 nasopharyngeal cancer patients were acquired by IP and screen-film system respectively. Two doctors with similar experience evaluated the damage degree of petrosal bone, the receiver operating characteristic (ROC) curve of CR images and general images were drawn according to two doctors evaluation results. Results: The identification frequency of CR system and screen-film system were 1.159 and 0.806 Lp/mm respectively. For doctor one, the area under ROC curve of CR images and general images were 0.802 and 0.742 respectively. For doctor two, the area under ROC curve of CR images and general images were 0.751 and 0.600 respectively. The MTF curve and ROC curve of CR are both better than those of screen-film system. Conclusion: The image quality of CR portal imaging is much better than that of screen-film system. The utility of CR in linear accelerator for portal imaging is promising in clinic. (authors)

  18. The PORTAL OF SOCIAL CONTROL IN HEALTH: academic strategy for strengthening the public health system.

    Directory of Open Access Journals (Sweden)

    Elioenai Dornelles Alves

    2010-12-01

    Full Text Available This portal UNB had the institutional support through DEX and the CPD of UNB creating a website specifi c for hosting applications and certifi cations. referrals this portal, we have the following results:the possibility of disclosing the Journal Management & Health and referrals of local health councils, such as events, debates, legislation and forums. Currently, The portal is hosted by thesite of the Center for Research on Education and Health Promotion - NESPROM of UNB. Continuing this portal was the embryo for creating training courses counselors and multipliers theme social control on health, depending on support for updating and continuity information.

  19. NONLINEAR DYNAMICAL SYSTEMS - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Philip Holmes

    2005-12-31

    This document is the final report on the work completed on DE-FG02-95ER25238 since the start of the second renewal period: Jan 1, 2001. It supplements the annual reports submitted in 2001 and 2002. In the renewal proposal I envisaged work in three main areas: Analytical and topological tools for studying flows and maps Low dimensional models of fluid flow Models of animal locomotion and I describe the progess made on each project.

  20. Radiation portal evaluation parameters

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    The detection of the unauthorized movement of radioactive materials is one of the most effective nonproliferation measures. Automatic special nuclear material (SNM) portal monitors are designed to detect this unauthorized movement and are an important part of the safeguard systems at US nuclear facilities. SNM portals differ from contamination monitors because they are designed to have high sensitivity for the low energy gamma-rays associated with highly enriched uranium (HEU) and plutonium. These instruments are now being installed at international borders to prevent the spread of radioactive contamination an SNM. In this paper the parameters important to evaluating radiation portal monitors are discussed. (author)

  1. From a Content Delivery Portal to a Knowledge Management System for Standardized Cancer Documentation.

    Science.gov (United States)

    Schlue, Danijela; Mate, Sebastian; Haier, Jörg; Kadioglu, Dennis; Prokosch, Hans-Ulrich; Breil, Bernhard

    2017-01-01

    Heterogeneous tumor documentation and its challenges of interpretation of medical terms lead to problems in analyses of data from clinical and epidemiological cancer registries. The objective of this project was to design, implement and improve a national content delivery portal for oncological terms. Data elements of existing handbooks and documentation sources were analyzed, combined and summarized by medical experts of different comprehensive cancer centers. Informatics experts created a generic data model based on an existing metadata repository. In order to establish a national knowledge management system for standardized cancer documentation, a prototypical tumor wiki was designed and implemented. Requirements engineering techniques were applied to optimize this platform. It is targeted to user groups such as documentation officers, physicians and patients. The linkage to other information sources like PubMed and MeSH was realized.

  2. Resveratrol Reduces the Incidence of Portal Vein System Thrombosis after Splenectomy in a Rat Fibrosis Model

    Science.gov (United States)

    Xu, Meng; Xue, Wanli; Ma, Zhenhua; Bai, Jigang

    2016-01-01

    Purpose. To investigate the preventive effect of resveratrol (RES) on the formation of portal vein system thrombosis (PVST) in a rat fibrosis model. Methods. A total of 64 male SD rats, weighing 200–300 g, were divided into five groups: Sham operation, Splenectomy I, Splenectomy II, RES, and low molecular weight heparin (LMWH), with the former two groups as nonfibrosis controls. Blood samples were subjected to biochemical assays. Platelet apoptosis was measured by flow cytometry. All rats were euthanized for PVST detection one week after operation. Results. No PVST occurred in nonfibrosis controls. Compared to Splenectomy II, the incidences of PVST in RES and LMWH groups were significantly decreased (both p Splenectomy II (all p splenectomy in cirrhotic rat. Regulation of platelet function and induction of platelet apoptosis might be the underlying mechanisms. PMID:27433290

  3. A Web portal for the Engineering and Equipment Data Management System at CERN

    CERN Document Server

    Tsyganov, A; Martel, P; Milenkovic, S; Suwalska, A; Delamare, Christophe; Widegren, David; Mallon Amerigo, S; Pettersson, Thomas Sven

    2010-01-01

    CERN, the European Laboratory for Particle Physics, located in Geneva – Switzerland, has recently started the Large Hadron Collider (LHC), a 27 km particle accelerator. The CERN Engineering and Equipment Data Management Service (EDMS) provides support for managing engineering and equipment information throughout the entire lifecycle of a project. Based on several both in-house developed and commercial data management systems, this service supports management and follow-up of different kinds of information throughout the lifecycle of the LHC project: design, manufacturing, installation, commissioning data, maintenance and more. The data collection phase, carried out by specialists, is now being replaced by a phase during which data will be consulted on an extensive basis by non-experts users. In order to address this change, a Web portal for the EDMS has been developed. It brings together in one space all the aspects covered by the EDMS: project and document management, asset tracking and safety follow-up. T...

  4. The Design and Implementation of a Prototype Web-Portal for the Integrated Mobile Alerting System (IMAS)

    National Research Council Canada - National Science Library

    Le, Phong D; Hsu, Michael

    2006-01-01

    .... It demonstrates that a web-portal written in PHP script supported by a relational database is a good configuration for IMAS. Additionally, a proof of concept system that converts messages into disseminated mobile alerts is presented. This thesis marks the founding steps in developing the IMAS.

  5. Extensive tumor thrombus of hepatocellular carcinoma in the entire portal venous system detected on fluorodeoxyglucose positron emission tomography computed tomography

    International Nuclear Information System (INIS)

    Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Puranik, Ameya; Rangarajan, Venkatesh

    2013-01-01

    Detection of thrombus is usually an incidental finding on fluorodeoxyglucose positron emission tomography/computed tomography studies. Nevertheless this is an important finding in terms of disease prognostication and in planning the treatment strategy. We herein report a case of a 50-years-old male, a diagnosed case of hepatocellular carcinoma with extensive hypermetabolic thrombus involving the entire portal venous system. (author)

  6. Implementation of a program of quality assurance of image in an imaging system of flat panel portal; Puesta en marcha de un programa de garantia de calidad de imagen en un sistema de imagen portal de panel plano

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Barrado, A.; Sanchez Jimenez, E.; Benitez, J. A.; Sanchez-Reyes, A.

    2013-07-01

    (IGRT) image-guided radiation therapy is the one in which images are used to locate the area of treatment. Modern irradiation systems are equipped with different modalities for obtaining images, such as flat panel systems, systems conebeam, tomoimagen, etc. This paper describes the start-up and the experience of a quality assurance program based on a flat panel portal Imaging System. (Author)

  7. Experimental lithium system. Final report

    International Nuclear Information System (INIS)

    Kolowith, R.; Berg, J.D.; Miller, W.C.

    1985-04-01

    A full-scale mockup of the Fusion Materials Irradiation Test (FMIT) Facility lithium system was built at the Hanford Engineering Development Laboratory (HEDL). This isothermal mockup, called the Experimental Lithium System (ELS), was prototypic of FMIT, excluding the accelerator and dump heat exchanger. This 3.8 m 3 lithium test loop achieved over 16,000 hours of safe and reliable operation. An extensive test program demonstrated satisfactory performance of the system components, including the HEDL-supplied electromagnetic lithium pump, the lithium jet target, the purification and characterization hardware, as well as the auxiliary argon and vacuum systems. Experience with the test loop provided important information on system operation, performance, and reliability. This report presents a complete overview of the entire Experimental Lithium System test program and also includes a summary of such areas as instrumentation, coolant chemistry, vapor/aerosol transport, and corrosion

  8. Transjugular intrahepatic porto-systemic shunt in the elderly: Palliation for complications of portal hypertension

    Science.gov (United States)

    Syed, Mubin I; Karsan, Hetal; Ferral, Hector; Shaikh, Azim; Waheed, Uzma; Akhter, Talal; Gabbard, Alan; Morar, Kamal; Tyrrell, Robert

    2012-01-01

    AIM: To present a dedicated series of transjugular intrahepatic porto-systemic shunts (TIPS) in the elderly since data is sparse on this population group. METHODS: A retrospective review was performed of patients at least 65 years of age who underwent TIPS at our institutions between 1997 and 2010. Twenty-five patients were referred for TIPS. We deemed that 2 patients were not considered appropriate candidates due to their markedly advanced liver disease. Of the 23 patients suitable for TIPS, the indications for TIPS placement was portal hypertension complicated by refractory ascites alone (n = 9), hepatic hydrothorax alone (n = 2), refractory ascites and hydrothorax (n = 1), gastrointestinal bleeding alone (n = 8), gastrointestinal bleeding and ascites (n = 3). RESULTS: Of these 23 attempted TIPS procedure patients, 21 patients had technically successful TIPS procedures. A total of 29 out of 32 TIPS procedures including revisions were successful in 21 patients with a mean age of 72.1 years (range 65-82 years). Three of the procedures were unsuccessful attempts at TIPS and 8 procedures were successful revisions of our existing TIPS. Sixteen of 21 patients who underwent successful TIPS (excluding 5 patients lost to follow-up) were followed for a mean of 14.7 mo. Ascites and/or hydrothorax was controlled following technically successful procedures in 12 of 13 patients. Bleeding was controlled following technically successful procedures in 10 out of 11 patients. CONCLUSION: We have demonstrated that TIPS is an effective procedure to control refractory complications of portal hypertension in elderly patients. PMID:22400084

  9. Splenectomy Causes 10-Fold Increased Risk of Portal Venous System Thrombosis in Liver Cirrhosis Patients.

    Science.gov (United States)

    Qi, Xingshun; Han, Guohong; Ye, Chun; Zhang, Yongguo; Dai, Junna; Peng, Ying; Deng, Han; Li, Jing; Hou, Feifei; Ning, Zheng; Zhao, Jiancheng; Zhang, Xintong; Wang, Ran; Guo, Xiaozhong

    2016-07-19

    BACKGROUND Portal venous system thrombosis (PVST) is a life-threatening complication of liver cirrhosis. We conducted a retrospective study to comprehensively analyze the prevalence and risk factors of PVST in liver cirrhosis. MATERIAL AND METHODS All cirrhotic patients without malignancy admitted between June 2012 and December 2013 were eligible if they underwent contrast-enhanced CT or MRI scans. Independent predictors of PVST in liver cirrhosis were calculated in multivariate analyses. Subgroup analyses were performed according to the severity of PVST (any PVST, main portal vein [MPV] thrombosis >50%, and clinically significant PVST) and splenectomy. Odds ratios (ORs) and 95% confidence intervals (CIs) were reported. RESULTS Overall, 113 cirrhotic patients were enrolled. The prevalence of PVST was 16.8% (19/113). Splenectomy (any PVST: OR=11.494, 95%CI=2.152-61.395; MPV thrombosis >50%: OR=29.987, 95%CI=3.247-276.949; clinically significant PVST: OR=40.415, 95%CI=3.895-419.295) and higher hemoglobin (any PVST: OR=0.974, 95%CI=0.953-0.996; MPV thrombosis >50%: OR=0.936, 95%CI=0.895-0.980; clinically significant PVST: OR=0.935, 95%CI=0.891-0.982) were the independent predictors of PVST. The prevalence of PVST was 13.3% (14/105) after excluding splenectomy. Higher hemoglobin was the only independent predictor of MPV thrombosis >50% (OR=0.952, 95%CI=0.909-0.997). No independent predictors of any PVST or clinically significant PVST were identified in multivariate analyses. Additionally, PVST patients who underwent splenectomy had a significantly higher proportion of clinically significant PVST but lower MELD score than those who did not undergo splenectomy. In all analyses, the in-hospital mortality was not significantly different between cirrhotic patient with and without PVST. CONCLUSIONS Splenectomy may increase by at least 10-fold the risk of PVST in liver cirrhosis independent of severity of liver dysfunction.

  10. Development of Sales and Inventory Workflow Management Information System Web Portal for Petrospan Integrated Services, Eket, Akwa Ibom State, Nigeria

    OpenAIRE

    Ezeonwumelu, Adanna Ngozi; Eunice, Akinloye Bolanle; Ezenugu, Isaac A.

    2017-01-01

    In this paper, the development of Sales and Inventory Workflow Management Information System (SIWfMS) web portal for Petrospan Integrated Services, Eket, Akwa Ibom state, Nigeria was presented. Rapid Application Development (RAP) methodology is used in the web application development. Three-tier architecture based on WAMP server configuration was adopted. The WAMP server was made up of Windows Operating system; Apache web server, MySQL database system and PHP server-side scripting langue. The...

  11. Prominent porto-systemic collateral pathways in patients with portal hypertension: demonstration by gadolinium-enhanced magnetic resonance angiography; Vias colaterais porto-sistemicas exuberantes em portadores de hipertensao portal: demonstracao pela angiografia por ressonancia magnetica com gadolinio

    Energy Technology Data Exchange (ETDEWEB)

    Caldana, Rogerio Pedreschi; Bezerra, Alexandre Araujo Sergio; Cecin, Alexnadre Oliveira; Souza, Luis Ronan Marques Ferreira de; Goldman, Susan Menasce; D' Ippolito, Giuseppe; Szejnfeld, Jacob [Universidade Federal de Sao Paulo (UNIFESP/EPM), Sao Paulo, SP (Brazil). Dept. de Diagnostico por Imagem]. E-mail: rogercal@uol.com.br

    2003-03-01

    To demonstrate the usefulness of gadolinium-enhanced magnetic resonance angiography in the evaluation of prominent porto-systemic collateral pathways. We reviewed the images from 40 patients with portal hypertension studied with gadolinium-enhanced magnetic resonance angiography and selected illustrative cases of prominent porto-systemic collateral pathways. The scans were performed using high field equipment (1.5 Tesla) and a 3 D volume technique. Image were obtained after intravenous injection of paramagnetic contrast media using a power injector. Magnetic resonance angiography demonstrated with precision the porto-systemic collateral pathways, particularly when investigating extensive territories or large vessels. The cases presented show the potential of this method in the investigation of patients with portal hypertension. Gadolinium-enhanced magnetic resonance angiography is a useful method for the evaluation of patients with portal hypertension and prominent collateral pathways. (author)

  12. Portal verification using the KODAK ACR 2000 RT storage phosphor plate system and EC registered films. A semiquantitative comparison

    International Nuclear Information System (INIS)

    Geyer, P.; Blank, H.; Alheit, H.

    2006-01-01

    Background and Purpose: the suitability of the storage phosphor plate system ACR 2000 RT (Eastman Kodak Corp., Rochester, MN, USA), that is destined for portal verification as well as for portal simulation imaging in radiotherapy, had to be proven by the comparison with a highly sensitive verification film. Material and Methods: the comparison included portal verification images of different regions (head and neck, thorax, abdomen, and pelvis) irradiated with 6- and 15-MV photons and electrons. Each portal verification image was done at the storage screen and the EC registered film as well, using the EC-L registered cassettes (both: Eastman Kodak Corp., Rochester, MN, USA) for both systems. The soft-tissue and bony contrast and the brightness were evaluated and compared in a ranking of the two compared images. Different phantoms were irradiated to investigate the high- and low-contrast resolution. To account for quality assurance application, the short-time exposure of the unpacked and irradiated storage screen by green and red room lasers was also investigated. Results: in general, the quality of the processed ACR images was slightly higher than that of the films, mostly due to cases of an insufficient exposure to the film. The storage screen was able to verify electron portals even for low electron energies with only minor photon contamination. The laser lines were sharply and clearly visible on the ACR images. Conclusion: the ACR system may replace the film without any noticeable decrease in image quality thereby reducing processing time and saving the costs of films and avoiding incorrect exposures. (orig.)

  13. Roadside Tracker Portal-less Portal Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Ziock, Klaus-Peter [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cheriyadat, Anil M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bradley, Eric Craig [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cunningham, Mark F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fabris, Lorenzo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goddard, Jr, James Samuel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hornback, Donald Eric [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Karnowski, Thomas Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kerekes, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Newby, Jason [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-07-01

    This report documents the full development cycle of the Roadside Tracker (RST) Portal-less Portal monitor (Fig. 1) funded by DHS DNDO. The project started with development of a proof-of-feasibility proto-type, proceeded through design and construction of a proof-of-concept (POC) prototype, a test-and-evaluation phase, participation in a Limited Use Exercise that included the Standoff Radiation Detections Systems developed under an Advanced Technology Demonstration and concluded with participation in a Characterization Study conducted by DNDO.

  14. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  15. GEO portal

    Data.gov (United States)

    US Agency for International Development — The USAID GeoPortal is a new application that groups web-based capabilities for on-demand discovery of and access to geospatial content, services, expertise, and...

  16. Circulating CXCL10 in cirrhotic portal hypertension might reflect systemic inflammation and predict ACLF and mortality

    DEFF Research Database (Denmark)

    Lehmann, Jennifer M; Claus, Karina; Jansen, Christian

    2018-01-01

    BACKGROUND & AIMS: CXCR% ligands play an important role in hepatic injury, inflammation and fibrosis. While CXCL9 and CXCL11 are associated with survival in patients receiving transjugular intrahepatic portosystemic shunt (TIPS), the role of CXCL10 in severe portal hypertension remains unknown...... inflammation and it is correlated with acute decompensation, ACLF and complications in patients with severe portal hypertension receiving TIPS. CXCL10 predicts survival in these patients and a decrease in CXCL10 after TIPS may be considered a good prognostic factor........ METHODS: A total of 89 cirrhotic patients were analysed. CXCL10 protein levels were measured in portal and hepatic blood at TIPS insertion and 2 weeks later in 24 patients. CXCL10 and IL8 levels were assessed in portal, hepatic, cubital vein and right atrium blood in a further 25 patients at TIPS...

  17. Lunar power systems. Final report

    International Nuclear Information System (INIS)

    1986-12-01

    The findings of a study on the feasibility of several methods of providing electrical power for a permanently manned lunar base are provided. Two fundamentally different methods for lunar electrical power generation are considered. One is the use of a small nuclear reactor and the other is the conversion of solar energy to electricity. The baseline goal was to initially provide 300 kW of power with growth capability to one megawatt and eventually to 10 megawatts. A detailed, day by day scenario for the establishment, build-up, and operational activity of the lunar base is presented. Also presented is a conceptual approach to a supporting transportation system which identifies the number, type, and deployment of transportation vehicles required to support the base. An approach to the use of solar cells in the lunar environment was developed. There are a number of heat engines which are applicable to solar/electric conversions, and these are examined. Several approaches to energy storage which were used by the electric power utilities were examined and those which could be used at a lunar base were identified

  18. [Correlation between the width of lingual vein and the changes of hemodynamics of portal system in patients with primary liver cancer].

    Science.gov (United States)

    Yue, Xiao-Qiang; Gao, Jing-Dong; Zhai, Xiao-Feng; Liu, Qing; Jiang, Dong; Ling, Chang-Quan

    2006-09-01

    To explore the correlation between the width of lingual varix and changes of hemodynamics of portal system in patients with primary liver cancer so as to supply the data for the forecast of portal hypertension by observing lingual varix. The diameter of lingual vein (Dlv) was measured by vernier caliper as dependent variable, and the diameters and indexes of hemodynamics of portal vessels were measured by Doppler as independent variables, then a multipe stepwise analysis was performed. The diameters of portal vein (Dpv) and splenic vein (Dsv) entered the formula Dlv (mm) = 0.185 + 0.311 Dsv (mm) + 0.236 Dpv (mm) when the entry and removal values were alpha(in)=0.10 and alpha(out)=0.15, respectively. The width of lingual vein is closely correlated with the diameters of portal vein and splenic vein in patients with primary liver cancer.

  19. A user-oriented model for global enterprise portal design

    NARCIS (Netherlands)

    Feng, X.; Ehrenhard, Michel Léon; Hicks, Jeff; Maathuis, Stephanus Johannes; Maathuis, S.J.; Hou, Y.

    2010-01-01

    Enterprise portals collect and synthesise information from various systems to deliver personalised and highly relevant information to users. Enterprise portals' design and applications are widely discussed in the literature; however, the implications of portal design in a global networked

  20. Biology of portal hypertension.

    Science.gov (United States)

    McConnell, Matthew; Iwakiri, Yasuko

    2018-02-01

    Portal hypertension develops as a result of increased intrahepatic vascular resistance often caused by chronic liver disease that leads to structural distortion by fibrosis, microvascular thrombosis, dysfunction of liver sinusoidal endothelial cells (LSECs), and hepatic stellate cell (HSC) activation. While the basic mechanisms of LSEC and HSC dysregulation have been extensively studied, the role of microvascular thrombosis and platelet function in the pathogenesis of portal hypertension remains to be clearly characterized. As a secondary event, portal hypertension results in splanchnic and systemic arterial vasodilation, leading to the development of a hyperdynamic circulatory syndrome and subsequently to clinically devastating complications including gastroesophageal varices and variceal hemorrhage, hepatic encephalopathy from the formation of portosystemic shunts, ascites, and renal failure due to the hepatorenal syndrome. This review article discusses: (1) mechanisms of sinusoidal portal hypertension, focusing on HSC and LSEC biology, pathological angiogenesis, and the role of microvascular thrombosis and platelets, (2) the mesenteric vasculature in portal hypertension, and (3) future directions for vascular biology research in portal hypertension.

  1. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  2. The SNS/HFIR Web Portal System - How Can it Help Me?

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Stephen D; Geist, Al; Herwig, Kenneth W; Peterson, Peter F; Reuter, Michael A; Ren, Shelly; Bilheux, Jean-Christophe; Campbell, Stuart I; Kohl, James A; Vazhkudai, Sudharshan S; Cobb, John W; Lynch, Vickie E; Chen Meili; Trater, James R; Smith, Bradford C; Swain, Tom; Huang Jian [University of Tennessee, Knoxville, TN (United States); Mikkelson, Ruth; Mikkelson, Dennis, E-mail: millersd@ornl.gov

    2010-11-01

    In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops - the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a 'live cataloging' system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members

  3. The SNS/HFIR Web Portal System - How Can it Help Me?

    International Nuclear Information System (INIS)

    Miller, Stephen D; Geist, Al; Herwig, Kenneth W; Peterson, Peter F; Reuter, Michael A; Ren, Shelly; Bilheux, Jean-Christophe; Campbell, Stuart I; Kohl, James A; Vazhkudai, Sudharshan S; Cobb, John W; Lynch, Vickie E; Chen Meili; Trater, James R; Smith, Bradford C; Swain, Tom; Huang Jian; Mikkelson, Ruth; Mikkelson, Dennis

    2010-01-01

    In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops - the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a 'live cataloging' system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to

  4. The SNS/HFIR Web Portal System - How Can it Help Me?

    Science.gov (United States)

    Miller, Stephen D.; Geist, Al; Herwig, Kenneth W.; Peterson, Peter F.; Reuter, Michael A.; Ren, Shelly; Bilheux, Jean-Christophe; Campbell, Stuart I.; Kohl, James A.; Vazhkudai, Sudharshan S.; Cobb, John W.; Lynch, Vickie E.; Chen, Meili; Trater, James R.; Smith, Bradford C.; (William Swain, Tom; Huang, Jian; Mikkelson, Ruth; Mikkelson, Dennis; een, Mar K. L. Gr

    2010-11-01

    In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops - the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a "live cataloging" system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to

  5. Portal pressure correlated to visceral circulation times

    Energy Technology Data Exchange (ETDEWEB)

    Friman, L [Serafimerlasarettet, Stockholm (Sweden)

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system.

  6. Portal pressure correlated to visceral circulation times

    International Nuclear Information System (INIS)

    Friman, L.

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system. (Auth.)

  7. Final focus systems for linear colliders

    International Nuclear Information System (INIS)

    Erickson, R.A.

    1987-11-01

    The final focus system of a linear collider must perform two primary functions, it must focus the two opposing beams so that their transverse dimensions at the interaction point are small enough to yield acceptable luminosity, and it must steer the beams together to maintain collisions. In addition, the final focus system must transport the outgoing beams to a location where they can be recycled or safely dumped. Elementary optical considerations for linear collider final focus systems are discussed, followed by chromatic aberrations. The design of the final focus system of the SLAC Linear Collider (SLC) is described. Tuning and diagnostics and steering to collision are discussed. Most of the examples illustrating the concepts covered are drawn from the SLC, but the principles and conclusions are said to be generally applicable to other linear collider designs as well. 26 refs., 17 figs

  8. Final Focus Systems in Linear Colliders

    International Nuclear Information System (INIS)

    Raubenheimer, Tor

    1998-01-01

    In colliding beam facilities, the ''final focus system'' must demagnify the beams to attain the very small spot sizes required at the interaction points. The first final focus system with local chromatic correction was developed for the Stanford Linear Collider where very large demagnifications were desired. This same conceptual design has been adopted by all the future linear collider designs as well as the SuperConducting Supercollider, the Stanford and KEK B-Factories, and the proposed Muon Collider. In this paper, the over-all layout, physics constraints, and optimization techniques relevant to the design of final focus systems for high-energy electron-positron linear colliders are reviewed. Finally, advanced concepts to avoid some of the limitations of these systems are discussed

  9. Assessment of a customised immobilisation system for head and neck IMRT using electronic portal imaging

    International Nuclear Information System (INIS)

    Humphreys, Mandy; Guerrero Urbano, M.Teressa; Mubata, Cefas; Miles, Elizabeth; Harrington, Kevin J.; Bidmead, Margaret; Nutting, Christopher M.

    2005-01-01

    Purpose: To evaluate set-up reproducibility of a cabulite shell and determine CTV-PTV margins for head and neck intensity-modulated-radiotherapy. Materials and methods: Twenty patients were entered into the study. A total of 354 anterior and lateral isocentric electronic portal images (EPIs) were compared to simulator reference images. Results: About 94% of all translational displacements were ≤3 mm, and 99% ≤5 mm. The overall systematic error was 0.9 mm (±1.0SD) in the Right-Left, 0.7 mm (±0.9SD) in the Superior-Inferior and -0.02 mm (±1.1SD) in the Anterior-Posterior directions. The corresponding SDs of the random errors were ±0.4, ±0.6 and ±0.7 mm. The estimated margins required from CTV-PTV were calculated according to the Van Herk formula was 2.9, 2.6 and 3.3 mm, respectively. Conclusions: This head and neck immobilisation system is of sufficient accuracy for its use with IMRT treatments and a 3 mm CTV-PTV margin has been adopted

  10. ASH External Web Portal (External Portal) -

    Data.gov (United States)

    Department of Transportation — The ASH External Web Portal is a web-based portal that provides single sign-on functionality, making the web portal a single location from which to be authenticated...

  11. EMODnet Physics: One-stop Portal to access Multiplatform Observing Systems

    Science.gov (United States)

    Novellino, Antonio; Benedetti, Giacomo; D'Angelo, Paolo; Gorringe, Patrick; Thjisse, Peter; Schaap, Dick; Pouliquen, Sylvie; Manzella, Giuseppe

    2016-04-01

    The EMODnet Physics is being developed through a stepwise approach in three major stages and is currently in its second phase of development (2013 - 2016). It is a one-stop portal to access to near real time and historical achieved data sets. It provides a combined array of services and functionalities (such as dynamic map facility for viewing and downloading, dashboard reporting and machine-to-machine communication services) to users for obtaining free of charge data, meta-data and data products on the physical conditions of European sea basins and oceans. Moreover, the system provides full interoperability with third-party software through WMS service, Web Service and Web catalogues in order to exchange data and products according to the most recent standards. In particular, interoperability is assured with the IODE Ocean Data Portal with which EMODnet Physics is collaborating. EMODnet Physics is built on and it is working in coordination and cooperation EuroGOOS-ROOSs, CMEMS and the SeaDataNet network of NODCs. By means of joint activities with its three pillars and with the most relevant Organizations and associations within the sector, EMODnet is undergoing significant improvements and expansion. In the last year, EMODnet Physics has steadily enhanced the number and type of platforms covered providing high quality data integrating sources from a growing network. In particular, a major step forward sees the integration of emerging measuring systems such as HF radars, which are able to provide the resolution of surface current speeds and directions covering large regions of the coastal oceans, and that now do populate the EMODnet Platform. Nowadays the system does integrate information by more than 7.300 stations, among which 2915 moorings, 2728 drifting buoys and around 1200 ARGO floats. EMODnet Physics was also updated with two ready-to-use data products: the Ice (Copernicus CMEMS - SEAICE_GLO_SEAICE_L4_NRT_OBSERVATIONS_011_001) and Sea Level Trends (produced

  12. High signal intensity lesion in basal ganglia on MR imaging: correlation with portal-systemic encephalopathy in liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Ju; Choi, Sun Jeong; Kim, Chang Soo; Kim, Sun Hee; Chung, Chun Phil; Kim, Yang Sook [Maryknoll Hospital, Pusan (Korea, Republic of)

    1993-01-15

    To evaluate of the relationship between basal ganglia lesion and portal-systemic encephalopathy, eleven patients who had clinically proved liver cirrhosis with superior mesenteric vein larger than 10mm in diameter on ultrasonogram underwent brain MR imaging. No evidence of clinical or neuropsychiatric disturbance was observed in any patient at the time of the MR examination. Brain MR imaging revealed basal ganglia lesion characterized by bilateral, symmetric, high signal intensity without edema or mass effect on spin echo T1-weighted images in nine patients which included three patients with the past history of portal-systemic encephalopathy. It was concluded that excepted in the circumstances of other causes of the high signal intensity in basal ganglia on T1-weighted images such as fat, methemoglobin, melanin, neurofibromatosis, dense calcification, and parenteral nutrition, bilateral and symmetric high signal intensity lesion in basal ganglia would be a useful MR finding of subclinical portal-systemic encephalopathy in liver cirrhosis patients with no clinical or neuropsychiatric symptoms and larger than 10mm in diameter of superior mesenteric vein in ultrasonography.

  13. High signal intensity lesion in basal ganglia on MR imaging: correlation with portal-systemic encephalopathy in liver cirrhosis

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Choi, Sun Jeong; Kim, Chang Soo; Kim, Sun Hee; Chung, Chun Phil; Kim, Yang Sook

    1993-01-01

    To evaluate of the relationship between basal ganglia lesion and portal-systemic encephalopathy, eleven patients who had clinically proved liver cirrhosis with superior mesenteric vein larger than 10mm in diameter on ultrasonogram underwent brain MR imaging. No evidence of clinical or neuropsychiatric disturbance was observed in any patient at the time of the MR examination. Brain MR imaging revealed basal ganglia lesion characterized by bilateral, symmetric, high signal intensity without edema or mass effect on spin echo T1-weighted images in nine patients which included three patients with the past history of portal-systemic encephalopathy. It was concluded that excepted in the circumstances of other causes of the high signal intensity in basal ganglia on T1-weighted images such as fat, methemoglobin, melanin, neurofibromatosis, dense calcification, and parenteral nutrition, bilateral and symmetric high signal intensity lesion in basal ganglia would be a useful MR finding of subclinical portal-systemic encephalopathy in liver cirrhosis patients with no clinical or neuropsychiatric symptoms and larger than 10mm in diameter of superior mesenteric vein in ultrasonography

  14. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  15. Reverse Engineering and Software Products Reuse to Teach Collaborative Web Portals: A Case Study with Final-Year Computer Science Students

    Science.gov (United States)

    Medina-Dominguez, Fuensanta; Sanchez-Segura, Maria-Isabel; Mora-Soto, Arturo; Amescua, Antonio

    2010-01-01

    The development of collaborative Web applications does not follow a software engineering methodology. This is because when university students study Web applications in general, and collaborative Web portals in particular, they are not being trained in the use of software engineering techniques to develop collaborative Web portals. This paper…

  16. Portal Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Hakan Demirci

    2016-01-01

    Full Text Available Portal vein thrombosis is an important cause of presinusoidal portal hypertension. Portal vein thrombosis commonly occurs in patient with cirrhosis, malignancy and prothrombotic states. Patients with acute portal vein thrombosis have immediate onset. Patients with chronic portal vein thrombosis have developed portal hypertension and cavernous portal transformation. Portal vein thrombosis is diagnosed with doppler ultrasound, computed tomography and magnetic resonance imaging. Therapy with low molecular weight heparin achieves recanalization in more than half of acute cases.

  17. CT portal venography manifestations of portal collateral circulation in patients with portal hypertension due to cirrhosis

    International Nuclear Information System (INIS)

    Ni Ming; Lv Weifu; Deng Kexue

    2009-01-01

    Objective: To analyze CT portal venography (CTPV) manifestations of portal collateral circulation in patients with cirrhosis by using a 16-detector row spiral CT scanner. Methods: CTPV was performed in 36 patients with portal hypertension due to cirrhosis, the diagnosis was proved by clinical data, hepatic function findings and imaging signs. By using post-processing reconstruction technique, 3D images of portal venous system and portal collateral circulation were obtained. Results: CTPV images displayed the portal venous system and its collateral circulation stereoscopically. Of 36 patients, left gastric varices were seen in 29(80.6%), lower esophageal varices in 18(50.0%), short gastric or posterior gastric varices in 15(41.7%), paraesophageal varices in 9(25.0%), gastro-renal or splenorenal shunts in 8(22.2%), spongelike transformation of portal vein in 7(19.4%), paraumbilical and abdominal wall varices in 6(16.7%), congenital cavernous in 6(16.7%) and paravertebral venous shunts in 4(11.1%). Conclusion: CTPV can well display the site, extent and severity of the portal collateral circulation in patients with portal hypertension due to cirrhosis,which is of great clinical importance for judging the patient's condition, for selecting therapeutic protocols and for estimating prognosis. (authors)

  18. Final focus systems for linear colliders

    International Nuclear Information System (INIS)

    Helm, R.; Irwin, J.

    1992-08-01

    Final focus systems for linear colliders present many exacting challenges in beam optics, component design, and beam quality. Efforts to resolve these problems as they relate to a new generation of linear colliders are under way at several laboratories around the world. We will outline criteria for final focus systems and discuss the current state of understanding and resolution of the outstanding problems. We will discuss tolerances on alignment, field quality and stability for optical elements, and the implications for beam parameters such as emittance, energy spread, bunch length, and stability in position and energy. Beam-based correction procedures, which in principle can alleviate many of the tolerances, will be described. Preliminary results from the Final Focus Test Beam (FFTB) under construction at SLAC will be given. Finally, we mention conclusions from operating experience at the Stanford Linear Collider (SLC)

  19. Final focus systems for linear colliders

    International Nuclear Information System (INIS)

    Helm, R.; Irwing, J.

    1992-01-01

    Final focus systems for linear colliders present many exacting challenges in beam optics, component design, and beam quality. Efforts to resolve these problems as they relate to a new generation of linear colliders are under way at several laboratories around the world. We outline criteria for final focus systems and discuss the current state of understanding and resolution of the outstanding problems. We discuss tolerances on alignment, field quality and stability for optical elements, and the implications for beam parameters such as emittance, energy spread , bunch length, and stability in position and energy. Beam-based correction procedures, which in principle can alleviate many of the tolerances, are described. Preliminary results from the Final Focus Test Beam (FFTB) under construction at SLAC are given. Finally, we mention conclusions from operating experience at the Stanford Linear Collider (SLC). (Author) 16 refs., 4 tabs., 6 figs

  20. WLCG Operations portal demo tutorial

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This is a navigation through http://wlcg-ops.web.cern.ch/ the Worldwide LHC Computing Grid (WLCG) Operations' portal. In this portal you will find documentation and information about WLCG Operation activities for: System Administrators at the WLCG sites LHC Experiments Operation coordination people, including Task Forces and Working Groups

  1. Barriers and Facilitators to Online Portal Use Among Patients and Caregivers in a Safety Net Health Care System: A Qualitative Study.

    Science.gov (United States)

    Tieu, Lina; Sarkar, Urmimala; Schillinger, Dean; Ralston, James D; Ratanawongsa, Neda; Pasick, Rena; Lyles, Courtney R

    2015-12-03

    Patient portals have the potential to support self-management for chronic diseases and improve health outcomes. With the rapid rise in adoption of patient portals spurred by meaningful use incentives among safety net health systems (a health system or hospital providing a significant level of care to low-income, uninsured, and vulnerable populations), it is important to understand the readiness and willingness of patients and caregivers in safety net settings to access their personal health records online. To explore patient and caregiver perspectives on online patient portal use before its implementation at San Francisco General Hospital, a safety net hospital. We conducted 16 in-depth interviews with chronic disease patients and caregivers who expressed interest in using the Internet to manage their health. Discussions focused on health care experiences, technology use, and interest in using an online portal to manage health tasks. We used open coding to categorize all the barriers and facilitators to portal use, followed by a second round of coding that compared the categories to previously published findings. In secondary analyses, we also examined specific barriers among 2 subgroups: those with limited health literacy and caregivers. We interviewed 11 patients and 5 caregivers. Patients were predominantly male (82%, 9/11) and African American (45%, 5/11). All patients had been diagnosed with diabetes and the majority had limited health literacy (73%, 8/11). The majority of caregivers were female (80%, 4/5), African American (60%, 3/5), caregivers of individuals with diabetes (60%, 3/5), and had adequate health literacy (60%, 3/5). A total of 88% (14/16) of participants reported interest in using the portal after viewing a prototype. Major perceived barriers included security concerns, lack of technical skills/interest, and preference for in-person communication. Facilitators to portal use included convenience, health monitoring, and improvements in patient

  2. Wedge-shaped lesion in the liver seen on postoperative CT. Probable thromboembolic phenomenon in the portal venous system

    International Nuclear Information System (INIS)

    Yoshimitsu, K.; Charnsangavej, C.; Mi Park, J.; Ibukuro, K.

    1996-01-01

    Retrospective review of teaching files in our institution revealed 18 cases showing postoperative WSL in the liver. We also retrospectively reviewed CT images of the liver in 104 patients with a recent history of abdominopelvic surgery performed during a period of 12 months, as well as in 102 patients with no history of surgery during the same period to be used as control. Three additional patients with WSL were found in the postoperative group and none in the control group. Liver CT images from the 21 patients showing WSL, along with their clinical data and follow-up CT where available, were retrospectively analyzed. I.v. contrast-enhanced CT showed homogeneous higher attenuation of WSL than the surrounding liver in all cases; unenhanced CT showed low density in 5 patients, isodensity in 7 patients, and high density in 5 patients as compared with the surrounding liver. Density of unenhanced CT was significantly correlated with the presence or grade of fatty liver. In 5 cases CT demonstrated clots in the portal vein branch within the area of WSL and in 2 cases portal perfusion defects were observed on arterial portal CT, corresponding to the areas of WSL. Follow-up CT examinations were available on 15 patients: WSL became less prominent, or atrophic, or showed no change in 10, 2 and 3 patients respectively. Follow-up CT showed development of liver metastasis in only 3 cases. Only 2 of the 21 patients were clinically symptomatic; one had postoperative ileus and the other obstructive jaundice. Postoperative WSL may represent a thromboembolic phenomenon at the peripheral intrahepatic branch of the portal venous system during or after abdominopelvic surgery, resulting in a compensatory increase in the hepatic arterial flow that appears as wedge-shaped enhancement on CT. (orig./MG)

  3. Studies on portal systemic circulation by oral administration of 201Tl enclosed enteric coated capsule

    International Nuclear Information System (INIS)

    Tonami, Norihisa; Nakajima, Kenichi; Watanabe, Naoto

    1986-01-01

    Thallium-201 enclosed enteric coated capsule was prepared and administered orally to evaluate portal systemic circulation in 11 control subjects and 31 patients with various liver diseases by investigating scintigraphic appearance and the heart-to-liver uptake ratio (H/L ratio). In 10 patients with liver cirrhosis and one with chronic hepatitis, the results of H/L ratio were compared to those obtained by 201 Tl per-rectal administration. 1. It was fundamentally confirmed that 201 Tl enclosed enteric coated capsule was not broken down in the artificial gastric juice, but nearly completely melted 15 minutes after soaking in the artificial intestinal juice. 2. Clinical study was successfully completed in 36 out of 42 cases (86 %). Unsuccessful cases were found in 2 with capsule collapse in the stomach and 4 with its poor moving to the duodenum. 3. In control subjects the liver was clearly visualized and the mean value of H/L ratio was 0.32 which is lower than that of 201 Tl per-rectal administration previously reported. H/L ratio in patients with chronic and acute hepatitis was nearly equal to that in control subjects. H/L ratio in patients with liver cirrhosis was slightly higher than that in control subjects, but there was no significant difference between them. In cases with esophageal varices, H/L ratio was not so high compared to that in control subjects. Out of 7 patients showing high H/L ratio more than 0.8 in 201 Tl per-rectal administration, only one showed similar high ratio (1.07) in oral administration of 201 Tl enclosed enteric coated capsule. In this case the shunting from superior mesenteric vein to inferior vena cava connection was confirmed. From these results, it was considered that the shunting volume of superior mesenteric vein through esophageal varices is small. 4. A possibility of a new administration of radioisotope with enteric coated capsule was emphasized. (author)

  4. The stabilisation of final focus system

    Indian Academy of Sciences (India)

    The StaFF (stabilisation of final focus) system will use interferometers to monitor the relative ... quadrupole magnets will be the most demanding application, where mutual and beam- ... interferometers to measure lines of a geodetic network to record relative motion between two beam ... coupled interferometer design.

  5. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  6. Treatment verification system in radiotherapy using a digital portal imaging device. Comparison with screen/film systems

    International Nuclear Information System (INIS)

    Nakata, Manabu; Komai, Yoshinori; Okada, Takashi; Fukumoto, Satoshi; Chadani, Kazuma; Nohara, Hiroki; Kazusa, Chudou.

    1994-01-01

    A digital portal imaging (DPI) system for megavoltage photon beams was installed recently in our department. The purpose of this study is to evaluate the image quality of this system. We have analyzed the following properties of the system; relationship between measured dose-rate and pixel values of the DPI, spatial resolution, detectability of low-contrast objects and setup errors. The results were compared with those of conventional screen-film systems. As a result, the relationship between the measured dose-rate and the pixel value of the DPI was found to be linear in the dose-rate range between 100 and 400 cGy/min. Spatial resolution was 1.25 and 0.5 mm for the DPI and the screen-film systems, respectively. The slope of the contrast-detail curves differed between the DPI and the screen-film systems, the contrast thresholds were 0.6 and 0.3% for the DPI and the screen-film systems, respectively. The detectability of a setup error of 1 mm and 2 mm for the DPI was lower than that by the screen-film systems, although the difference was not very significant. In conclusion, the image quality of the DPI at present time is slightly inferior to the conventional screen-film systems. However, notable advantages of the DPI system are that any positional changes in patients during irradiation can be detected very quickly, and that quantitative analysis of the setup variation can be obtained. The image quality of the DPI will be improved as the technology regarding advances. Therefore, this verification system using the DPI device, is expected to be used for clinical radiation therapy in the future. (author)

  7. Portal monitoring technology control process

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    Portal monitors are an important part of the material protection, control, and accounting (MPC and A) programs in Russia and the US. Although portal monitors are only a part of an integrated MPC and A system, they are an effective means of controlling the unauthorized movement of special nuclear material (SNM). Russian technical experts have gained experience in the use of SNM portal monitors from US experts ad this has allowed them to use the monitors more effectively. Several Russian institutes and companies are designing and manufacturing SNM portal monitors in Russia. Interactions between Russian and US experts have resulted in improvements to the instruments. SNM portal monitor technology has been effectively transferred from the US to Russia and should be a permanent part of the Russian MPC and A Program. Progress in the implementation of the monitors and improvements to how they are used are discussed

  8. New Technology and Experimental Study on Snow-Melting Heated Pavement System in Tunnel Portal

    OpenAIRE

    Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Fan, Haobo; Wang, Ke

    2015-01-01

    In recent years, with the rapid growth of economy and sharp rise of motor vehicles in China, the pavement skid resistance in tunnel portals has become increasingly important in cold region. However, the deicing salt, snow removal with machine, and other antiskid measures adopted by highway maintenance division have many limitations. To improve the treatment effect, we proposed a new snow-melting approach employing electric heat tracing, in which heating cables are installed in the structural ...

  9. Studies on portal systemic circulation by oral administration of /sup 201/Tl enclosed enteric coated capsule

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Norihisa; Nakajima, Kenichi; Watanabe, Naoto and others

    1986-03-01

    Thallium-201 enclosed enteric coated capsule was prepared and administered orally to evaluate portal systemic circulation in 11 control subjects and 31 patients with various liver diseases by investigating scintigraphic appearance and the heart-to-liver uptake ratio (H/L ratio). In 10 patients with liver cirrhosis and one with chronic hepatitis, the results of H/L ratio were compared to those obtained by /sup 201/Tl per-rectal administration. 1. It was fundamentally confirmed that /sup 201/Tl enclosed enteric coated capsule was not broken down in the artificial gastric juice, but nearly completely melted 15 minutes after soaking in the artificial intestinal juice. 2. Clinical study was successfully completed in 36 out of 42 cases (86 %). Unsuccessful cases were found in 2 with capsule collapse in the stomach and 4 with its poor moving to the duodenum. 3. In control subjects the liver was clearly visualized and the mean value of H/L ratio was 0.32 which is lower than that of /sup 201/Tl per-rectal administration previously reported. H/L ratio in patients with chronic and acute hepatitis was nearly equal to that in control subjects. H/L ratio in patients with liver cirrhosis was slightly higher than that in control subjects, but there was no significant difference between them. In cases with esophageal varices, H/L ratio was not so high compared to that in control subjects. Out of 7 patients showing high H/L ratio more than 0.8 in /sup 201/Tl per-rectal administration, only one showed similar high ratio (1.07) in oral administration of /sup 201/Tl enclosed enteric coated capsule. In this case the shunting from superior mesenteric vein to inferior vena cava connection was confirmed. From these results, it was considered that the shunting volume of superior mesenteric vein through esophageal varices is small. 4. A possibility of a new administration of radioisotope with enteric coated capsule was emphasized.

  10. Association of gene polymorphisms of the reninangiotensin system and endothelial dysfunction with development and severity of portal hypertension in patients with chronic hepatitis C

    Directory of Open Access Journals (Sweden)

    O. V. Taratina

    2016-01-01

    Full Text Available Background: At present, much attention is paid to genetic factors explaining the clinical course of chronic hepatitis C. Aim: To evaluate an association of the gene polymorphisms involved in the formation of endothelial dysfunction (NOS3 894G/T, CYBA 242C/T, MTHFR 677C/T and encoding components of the renin-angiotensin system (ATR1 1166A/C, AGT (-6G/T and 235M/T with development and severity of portal hypertension syndrome in patients with chronic hepatitis C. Materials and methods: 162 patients with chronic hepatitis C and HCV-related cirrhosis (114 women and 48 men were divided into the following groups: no portal hypertension (n = 98, "compensated" (n = 19 and "decompensated" (n = 45 portal hypertension. The gene polymorphisms were assessed by molecular genetic methods. Results: TT genotype of CYBA was more common in patients with portal hypertension than in those without (odds ratio (OR for TT = 3.59, p = 0.031. This difference becomes larger when comparing the decompensated portal hypertension group with the no portal hypertension group (OR TT = 5.46, p = 0.009. Other gene polymorphisms were not associated with development or decompensation of portal hypertension. Multivariate analysis of the impact of genetic, clinical and demographic factors showed that portal hypertension was associated primarily with patients age at the time of the study (Wald's х2 = 14.99 and with their body mass index (Wald's х2 = 4.35. After exclusion of these population-wide risk factors from the model, the development of portal hypertension correlated with the carriage of 235TT genotype of CYBA (Wald's х2 = 6.07, OR = 4.29 and (-6AA genotype AGT (Wald's х2 = 4.73, OR = 4.13, as well as with the lack of protective 235TT genotype AGT (Wald's х2 = 4.06, OR = 0.33. The combined effects of the studied gene polymorphisms on decompensation of the portal hypertension in patients with chronic HCV infection were similar. Conclusion: The development and increase in

  11. Assessment of portal venous system patency in the liver transplant candidate: A prospective study comparing ultrasound, microbubble-enhanced colour Doppler ultrasound, with arteriography and surgery

    International Nuclear Information System (INIS)

    Marshall, M.M.; Beese, R.C.; Muiesan, P.; Sarma, D.I.; O'Grady, J.; Sidhu, P.S.

    2002-01-01

    AIM: To determine the role of microbubble-enhanced colour Doppler ultrasound (CDUS) in assessing portal venous patency prior to liver transplantation. MATERIALS AND METHODS: Over a 2-year period, all patients with chronic liver disease undergoing routine pre-transplant CDUS examination in whom the portal venous system was inadequately demonstrated were recruited to the study. CDUS was performed in 368 patients and 33 patients (9%) were recruited. A repeat CDUS examination following an intravenous bolus injection of the microbubble contrast agent Levovist[reg] (Schering Healthcare AG, Berlin, Germany) was performed. Diagnostic confidence was recorded on a free linear analogue scale for both examinations. Findings were compared with indirect portography and surgery. RESULTS: Of the 33 patients with sub-optimal baseline examinations, improvement in portal vein visualization was achieved in 31 patients (94%). Median diagnostic confidence increased from 50% (interquartile range 30-60) to 90% (interquartile range 75-98) (P < 0.001) following administration of Levovist[reg]. Overall accuracy of portal vein assessment using microbubble-enhanced CDUS in 15 patients in whom a definitive diagnosis was made within 2 months was 87%. CONCLUSION: Microbubble-enhanced CDUS is a simple, inexpensive adjunct to standard pre liver transplant screening of the portal vein. It is particularly helpful in patients with end-stage cirrhosis who are at high risk of portal vein thrombosis and in whom the conventional examination is sub-optimal.Marshall, M.M. et al. (2002)

  12. The first stage of BFS integrated system for nuclear materials control and accounting. Final report

    International Nuclear Information System (INIS)

    1996-09-01

    The BFS computerized accounting system is a network-based one. It runs in a client/server mode. The equipment used in the system includes a computer network consisting of: One server computer system, including peripheral hardware and three client computer systems. The server is located near the control room of the BFS-2 facility outside of the 'stone sack' to ensure access during operation of the critical assemblies. Two of the client computer systems are located near the assembly tables of the BFS-1 and BFS-2 facilities while the third one being the Fissile Material Storage. This final report details the following topics: Computerized nuclear material accounting methods; The portal monitoring system; Test and evaluation of item control technology; Test and evaluation of radiation based nuclear material measurement equipment; and The integrated demonstration of nuclear material control and accounting methods

  13. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  14. Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance

    International Nuclear Information System (INIS)

    Lim, Sangwook; Ma, Sun Young; Jeung, Tae Sig; Yi, Byong Yong; Lee, Sang Hoon; Lee, Suk; Cho, Sam Ju; Choi, Jinho

    2012-01-01

    In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.

  15. Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sangwook, E-mail: medicalphysics@hotmail.com [Department of Radiation Oncology, Kosin University College of Medicine, Seo-gu, Busan (Korea, Republic of); Ma, Sun Young; Jeung, Tae Sig [Department of Radiation Oncology, Kosin University College of Medicine, Seo-gu, Busan (Korea, Republic of); Yi, Byong Yong [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States); Lee, Sang Hoon [Department of Radiation Oncology, Cheil General Hospital and Women' s Healthcare Center, Kwandong University College of Medicine, Jung-gu, Seoul (Korea, Republic of); Lee, Suk [Department of Radiation Oncology, College of Medicine, Korea University, Seongbuk-gu, Seoul (Korea, Republic of); Cho, Sam Ju [Department of Radiation Oncology, Eulji University School of Medicine, Eulji General Hospital, Nowon-gu, Seoul (Korea, Republic of); Choi, Jinho [Department of Radiation Oncology, Gachon University of Medicine and Science, Namdong-gu, Incheon (Korea, Republic of)

    2012-10-01

    In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.

  16. Usability evaluation of the South African National Accessibility Portal interactive voice response system

    CSIR Research Space (South Africa)

    Greeff, M

    2008-10-01

    Full Text Available , which contains a web container and an Enterprise JavaBean container (EJB container). • PostgreSQL as database. The database does not link into existing databases, but are custom-built. • The NAP Portal application consisting of EJB 3.0 com- pliant... components: Stateless Session Beans (SLSB), Stateful Session Beans (SFSB), Message-Driven Beans, and EJB 3.0 entities utilising a presentation technology known as JavaServer Faces, combined with a templat- ing framework. • These elements are glued...

  17. Are hepatic portal venous system components distributed equally to the liver? A MDCT study

    International Nuclear Information System (INIS)

    Incedayi, M.; Aribal, S.; Sivrioglu, A.; Sonmez, G.; Ozturk, E.; Yalcin, B.; Basekim, C.

    2012-01-01

    Full text: Objective: We aimed to evaluate the relationships between the splenic index, right and left hepatic lobe volumes, diameters of splenic vein (SV), superior mesenteric vein (SMV) and the portal vein (PV) by Multidetector Computerized Tomography (MDCT). We also investigated indirect signs of portal venous flow pattern using these parameters. Material and method: Following their contrast thoracoabdominal and abdominal 64-MDCT examinations, the images of 100 cases (61 males and 39 females) were evaluated retrospectively. The patients who were included in the study ranged from age 20 to 88 (mean age: 41,78). For each case, the splenic index, total hepatic volume, left and right hepatic volumes were calculated on the post-contrast portal venous phase (50th sec) images. Cases without any known liver and spleen diseases were included in the study. Spearman and Pearson's correlation tests were carried out with the purpose of determining the relationships between the variables. Results: A statistically significant relationship between the splenic index and left hepatic lobe volume and total volume was demonstrated (p=0.001). Positive correlations between the left hepatic lobe volume and splenic index (r=0.55) and between the right hepatic lobe volume and splenic index (r=0.32) were also exhibited. However, the correlation between the left hepatic lobe volume and the splenic index was relatively stronger compared to the correlation between the right hepatic lobe volume and the splenic index (r=0.55 versus r= 0.32). Between the diameter of the SMV and right hepatic lobe volume a statistically significant relation was demonstrated (p<0.0001), and according to Pearson's correlation analysis, a positive correlation of medium strength (r=0.36) was observed. Conclusion: In our study, the MDCT findings revealed statistically significant relations between the splenic index and the left lobe volume and between the diameter of the SMV and the right lobe volume. Information

  18. Knowledge, workflow and electronic document management in the system of the State Nuclear Regulatory Inspectorate of Ukraine. Preparing the platform development and implementation of the Knowledge Portal

    International Nuclear Information System (INIS)

    Bozhko, S.G.; Shevchenko, Yi.A.; Pecheritsya, O.V.; Singayivs'kij, A.M.

    2016-01-01

    The previous paper considered the creation of the system for management of nuclear knowledge, workflow and electronic documents (hereinafter called the Knowledge Portal) in the field of safe nuclear energy use. It presented initial steps needed to make an informed decision on the feasibility of implementing the Knowledge Portal and proposed methodological approaches based on practical experience of the State Nuclear Regulatory Inspectorate of Ukraine and the SSTC NRS. Further pre - project activities of the state body, local authorities, enterprises, institutions and organizations irrespective of ownership (hereinafter called the Institution) involve the development and drawing attention to the package of analytical, technical and feasibility documents. In particular, it is recommended to take into account the results of analyzing world trends in the development of information technology, audit status information and telecommunication systems (hereinafter - ITS) of the Institution, detailed strategy for the development of ITS Institution (hereinafter - the Strategy), the concept of the Knowledge Portal (hereinafter - the Concept) and preliminary technical solution The results of review and approval of the Concept and architecture solution by scientific and technical council of the Institution is the basis for the preparation of Ter ms of Reference (hereinafter - TOR) on the development of the Knowledge Portal, forming schedules for the procurement of hardware and software, works on the development and implementation of portal solutions and information security systems

  19. Intelligent interaction based on holographic personalized portal

    Directory of Open Access Journals (Sweden)

    Yadong Huang

    2017-06-01

    Full Text Available Purpose – The purpose of this paper is to study the architecture of holographic personalized portal, user modeling, commodity modeling and intelligent interaction. Design/methodology/approach – In this paper, the authors propose crowd-science industrial ecological system based on holographic personalized portal and its interaction. The holographic personality portal is based on holographic enterprises, commodities and consumers, and the personalized portal consists of accurate ontology, reliable supply, intelligent demand and smart cyberspace. Findings – The personalized portal can realize the information acquisition, characteristic analysis and holographic presentation. Then, the intelligent interaction, e.g. demand decomposition, personalized search, personalized presentation and demand prediction, will be implemented within the personalized portal. Originality/value – The authors believe that their work on intelligent interaction based on holographic personalized portal, which has been first proposed in this paper, is innovation focusing on the interaction between intelligence and convenience.

  20. SatisFactory Final System Evaluation Report

    OpenAIRE

    Sunlight SA

    2018-01-01

    The present document is a deliverable of the SatisFactory project, funded by the European Commission’s Directorate-General for Research and Innovation (DG RTD), under its Horizon 2020 Research and innovation programme (H2020). The main objective of this deliverable is to report on the SatisFactory Final System Evaluation, with regards to the industrial pilots at COMAU and SUNLIGHT. The evaluation of SatisFactory platform is based on the implementation of the business scenarios where each tool...

  1. Fast image acquisition and processing on a TV camera-based portal imaging system

    International Nuclear Information System (INIS)

    Baier, K.; Meyer, J.

    2005-01-01

    The present paper describes the fast acquisition and processing of portal images directly from a TV camera-based portal imaging device (Siemens Beamview Plus trademark). This approach employs not only hard- and software included in the standard package installed by the manufacturer (in particular the frame grabber card and the Matrox(tm) Intellicam interpreter software), but also a software tool developed in-house for further processing and analysis of the images. The technical details are presented, including the source code for the Matrox trademark interpreter script that enables the image capturing process. With this method it is possible to obtain raw images directly from the frame grabber card at an acquisition rate of 15 images per second. The original configuration by the manufacturer allows the acquisition of only a few images over the course of a treatment session. The approach has a wide range of applications, such as quality assurance (QA) of the radiation beam, real-time imaging, real-time verification of intensity-modulated radiation therapy (IMRT) fields, and generation of movies of the radiation field (fluoroscopy mode). (orig.)

  2. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  3. Study on the Seismic Response of a Portal Frame Structure Based on the Transfer Matrix Method of Multibody System

    Directory of Open Access Journals (Sweden)

    Jianguo Ding

    2014-11-01

    Full Text Available Portal frame structures are widely used in industrial building design but unfortunately are often damaged during an earthquake. As a result, a study on the seismic response of this type of structure is important to both human safety and future building designs. Traditionally, finite element methods such as the ANSYS and MIDAS have been used as the primary methods of computing the response of such a structure during an earthquake; however, these methods yield low calculation efficiencies. In this paper, the mechanical model of a single-story portal frame structure with two spans is constructed based on the transfer matrix method of multibody system (MS-TMM; both the transfer matrix of the components in the model and the total transfer matrix equation of the structure are derived, and the corresponding MATLAB program is compiled to determine the natural period and seismic response of the structure. The results show that the results based on the MS-TMM are similar to those obtained by ANSYS, but the calculation time of the MS-TMM method is only 1/20 of that of the ANSYS method. Additionally, it is shown that the MS-TMM method greatly increases the calculation efficiency while maintaining accuracy.

  4. Design of dual-road transportable portal monitoring system for visible light and gamma-ray imaging

    Science.gov (United States)

    Karnowski, Thomas P.; Cunningham, Mark F.; Goddard, James S.; Cheriyadat, Anil M.; Hornback, Donald E.; Fabris, Lorenzo; Kerekes, Ryan A.; Ziock, Klaus-Peter; Bradley, E. Craig; Chesser, J.; Marchant, W.

    2010-04-01

    The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third "alignment" camera for motion compensation and are mounted on a 50' deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

  5. Design of Dual-Road Transportable Portal Monitoring System for Visible Light and Gamma-Ray Imaging

    International Nuclear Information System (INIS)

    Karnowski, Thomas Paul; Cunningham, Mark F.; Goddard, James Samuel Jr.; Cheriyadat, Anil M.; Hornback, Donald Eric; Fabris, Lorenzo; Kerekes, Ryan A.; Ziock, Klaus-Peter; Bradley, Eric Craig; Chesser, Joel B.; Marchant, William

    2010-01-01

    The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third alignment camera for motion compensation and are mounted on a 50 deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

  6. DES Science Portal: Computing Photometric Redshifts

    Energy Technology Data Exchange (ETDEWEB)

    Gschwend, Julia [LIneA, Rio de Janeiro

    2016-01-01

    An important challenge facing photometric surveys for cosmological purposes, such as the Dark Energy Survey (DES), is the need to produce reliable photometric redshifts (photo-z). The choice of adequate algorithms and configurations and the maintenance of an up-to-date spectroscopic database to build training sets, for example, are challenging tasks when dealing with large amounts of data that are regularly updated and constantly growing. In this paper, we present the first of a series of tools developed by DES, provided as part of the DES Science Portal, an integrated web-based data portal developed to facilitate the scientific analysis of the data, while ensuring the reproducibility of the analysis. We present the DES Science Portal photometric redshift tools, starting from the creation of a spectroscopic sample to training the neural network photo-z codes, to the final estimation of photo-zs for a large photometric catalog. We illustrate this operation by calculating well calibrated photo-zs for a galaxy sample extracted from the DES first year (Y1A1) data. The series of processes mentioned above is run entirely within the Portal environment, which automatically produces validation metrics, and maintains the provenance between the different steps. This system allows us to fine tune the many steps involved in the process of calculating photo-zs, making sure that we do not lose the information on the configurations and inputs of the previous processes. By matching the DES Y1A1 photometry to a spectroscopic sample, we define different training sets that we use to feed the photo-z algorithms already installed at the Portal. Finally, we validate the results under several conditions, including the case of a sample limited to i<22.5 with the color properties close to the full DES Y1A1 photometric data. This way we compare the performance of multiple methods and training configurations. The infrastructure presented here is an effcient way to test several methods of

  7. LEARNERS’ SATISFACTION LEVEL WITH ONLINE STUDENT PORTAL AS A SUPPORT SYSTEM IN AN OPEN AND DISTANCE eLEARNING ENVIRONMENT (ODeL

    Directory of Open Access Journals (Sweden)

    Percia V. SECRETO

    2015-07-01

    Full Text Available Learner support in an open, distance and online learning is defined as “all activities and elements in education that respond to a known learner or group of learners, and which are designed to assist in the cognitive, affective, and systemic realms of the learning process” (Brindley, et. al, 2004. Teaching and tutoring, advising and counseling, and information and administration are the main institutional systems involved in learner support. The UP Open University functions under an open and distance e-learning (ODeL framework of distance education where most of its academic and non-academic processes are done through the Internet. It has developed an online Academic Information Management System (AIMS which serves as the gateway to the University’s academic operations. The Online Student Portal (OSP is the component of the system for the students. OSP serves such functionalities as online registration, viewing of grades, request for their records, payment of fees, and information hub. The study analyzed the learners’ satisfaction with the portal’s functionality, efficiency, appearance, ease of use, and security. An online survey was conducted of continuing undergraduate and graduate students (n=147 who were admitted prior to the implementation of the portal and thus had experienced both the manual and online processes. The survey was conducted from September 26 to October 3, 2013. In general, about 85 percent of those who participated in the survey were either very satisfied or satisfied with their overall experience of the portal. Ninety percent of the total participants found the portal cost-effective and informative. Overall, the participants identified the portal as a convenient and effective venue for getting accurate and immediate information about their performance, school activities, academic schedules, and other information relevant to their learning transactions. These features had made the portal an important student

  8. Noncirrotisk intrahepatisk portal hypertension

    DEFF Research Database (Denmark)

    Dam Fialla, Annette; Havelund, Troels

    2007-01-01

    Non-cirrhotic intrahepatic portal hypertension is characterized by portal hypertension in the absence of liver cirrhosis or portal vein thrombosis. The disease is common in the East and rarely seen in the West. Two cases with oesophageal varices are described. The histopathology is heterogeneous...... but includes vascular lesions and portal fibrosis. Patient management follows the current recommendations for variceal bleeding....

  9. Final Report: Hydrogen Storage System Cost Analysis

    Energy Technology Data Exchange (ETDEWEB)

    James, Brian David [Strategic Analysis Inc., Arlington, VA (United States); Houchins, Cassidy [Strategic Analysis Inc., Arlington, VA (United States); Huya-Kouadio, Jennie Moton [Strategic Analysis Inc., Arlington, VA (United States); DeSantis, Daniel A. [Strategic Analysis Inc., Arlington, VA (United States)

    2016-09-30

    The Fuel Cell Technologies Office (FCTO) has identified hydrogen storage as a key enabling technology for advancing hydrogen and fuel cell power technologies in transportation, stationary, and portable applications. Consequently, FCTO has established targets to chart the progress of developing and demonstrating viable hydrogen storage technologies for transportation and stationary applications. This cost assessment project supports the overall FCTO goals by identifying the current technology system components, performance levels, and manufacturing/assembly techniques most likely to lead to the lowest system storage cost. Furthermore, the project forecasts the cost of these systems at a variety of annual manufacturing rates to allow comparison to the overall 2017 and “Ultimate” DOE cost targets. The cost breakdown of the system components and manufacturing steps can then be used to guide future research and development (R&D) decisions. The project was led by Strategic Analysis Inc. (SA) and aided by Rajesh Ahluwalia and Thanh Hua from Argonne National Laboratory (ANL) and Lin Simpson at the National Renewable Energy Laboratory (NREL). Since SA coordinated the project activities of all three organizations, this report includes a technical description of all project activity. This report represents a summary of contract activities and findings under SA’s five year contract to the US Department of Energy (Award No. DE-EE0005253) and constitutes the “Final Scientific Report” deliverable. Project publications and presentations are listed in the Appendix.

  10. Radioisotopic evaluation of portal circulation

    International Nuclear Information System (INIS)

    Maliska, C.; Rosenthal, D.

    1986-01-01

    The use of a radio-tracer of portal circulation through the intestine, should prevent cruel punctures in the portal-vein or spleen as it is usually the case with traditional methods in the study of portal-system. The absorption of I-131 and Tc-99m, previously cheked in rabbits presented similar results in dogs. The time of circulation between terminal large-intestine and the liver (t-RF) was determined by external counting at hepatic level by recording radioactivity variation-time. In healthy animals the t-RF was from 20to 60 seconds, with average time of 42 seconds. In 2 animals with partial binding of portal-vein the t-RF went up to 110 and 120 seconds. (Author) [pt

  11. Multi-Point Combustion System: Final Report

    Science.gov (United States)

    Goeke, Jerry; Pack, Spencer; Zink, Gregory; Ryon, Jason

    2014-01-01

    A low-NOx emission combustor concept has been developed for NASA's Environmentally Responsible Aircraft (ERA) program to meet N+2 emissions goals for a 70,000 lb thrust engine application. These goals include 75 percent reduction of LTO NOx from CAEP6 standards without increasing CO, UHC, or smoke from that of current state of the art. An additional key factor in this work is to improve lean combustion stability over that of previous work performed on similar technology in the early 2000s. The purpose of this paper is to present the final report for the NASA contract. This work included the design, analysis, and test of a multi-point combustion system. All design work was based on the results of Computational Fluid Dynamics modeling with the end results tested on a medium pressure combustion rig at the UC and a medium pressure combustion rig at GRC. The theories behind the designs, results of analysis, and experimental test data will be discussed in this report. The combustion system consists of five radially staged rows of injectors, where ten small scale injectors are used in place of a single traditional nozzle. Major accomplishments of the current work include the design of a Multipoint Lean Direct Injection (MLDI) array and associated air blast and pilot fuel injectors, which is expected to meet or exceed the goal of a 75 percent reduction in LTO NOx from CAEP6 standards. This design incorporates a reduced number of injectors over previous multipoint designs, simplified and lightweight components, and a very compact combustor section. Additional outcomes of the program are validation that the design of these combustion systems can be aided by the use of Computational Fluid Dynamics to predict and reduce emissions. Furthermore, the staging of fuel through the individually controlled radially staged injector rows successfully demonstrated improved low power operability as well as improvements in emissions over previous multipoint designs. Additional comparison

  12. Depiction of variants of the portal confluence venous system using multidetector row CT. Analysis of 916 cases

    Energy Technology Data Exchange (ETDEWEB)

    Krumm, P.; Schraml, C.; Bretschneider, C.; Seeger, A.; Klumpp, B.; Kramer, U.; Claussen, C.D.; Miller, S. [Universitaetsklinikum Tuebingen (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie

    2011-12-15

    Purpose: Detailed knowledge of the venous mesenteric system is important for gastrointestinal surgery, particularly for transplantation planning and surgery and for the comprehension of perioperative complications that may influence patient outcome. Data about the mesenteric venous anatomy in the literature varies substantially. The purpose of this study was to categorize venous mesenteric variants and to determine their incidence. Materials and Methods: We included 916 patients requiring diagnostic abdominal CT in the portal venous phase. The mesenteric vein anatomy was categorized as follows: 1. the inferior mesenteric vein (IMV) enters the splenic vein (SV); 2. the IMV enters into the angle of the confluence of the SV and superior mesenteric vein (SMV) forming the portal vein (PV); 3. the IMV enters the SMV; 4. seven rare variants. We measured the diameters of the veins and distances from the confluence to the IMV origins. Results: The frequency of variants was: 1. 37.6 %, 2. 28.8 %; 3. 19.2 %. The rare variants totaled 14.4 %. The average vessel diameters measured in cm: PV 1.48; SV 1.02; SMV 1.2; IMV 0.5. The mean IMV entering distances were 1.66 cm in variant 1 and 0.75 cm in variant 3. Conclusion: The three common variants (1, 2 and 3) are the most relevant ones. 14.4 % of patients had different anatomic variants. The variability of the mesenteric venous system was higher than previously published. Knowledge of rare variants is important to avoid complications in abdominal surgery. (orig.)

  13. Depiction of variants of the portal confluence venous system using multidetector row CT. Analysis of 916 cases

    International Nuclear Information System (INIS)

    Krumm, P.; Schraml, C.; Bretschneider, C.; Seeger, A.; Klumpp, B.; Kramer, U.; Claussen, C.D.; Miller, S.

    2011-01-01

    Purpose: Detailed knowledge of the venous mesenteric system is important for gastrointestinal surgery, particularly for transplantation planning and surgery and for the comprehension of perioperative complications that may influence patient outcome. Data about the mesenteric venous anatomy in the literature varies substantially. The purpose of this study was to categorize venous mesenteric variants and to determine their incidence. Materials and Methods: We included 916 patients requiring diagnostic abdominal CT in the portal venous phase. The mesenteric vein anatomy was categorized as follows: 1. the inferior mesenteric vein (IMV) enters the splenic vein (SV); 2. the IMV enters into the angle of the confluence of the SV and superior mesenteric vein (SMV) forming the portal vein (PV); 3. the IMV enters the SMV; 4. seven rare variants. We measured the diameters of the veins and distances from the confluence to the IMV origins. Results: The frequency of variants was: 1. 37.6 %, 2. 28.8 %; 3. 19.2 %. The rare variants totaled 14.4 %. The average vessel diameters measured in cm: PV 1.48; SV 1.02; SMV 1.2; IMV 0.5. The mean IMV entering distances were 1.66 cm in variant 1 and 0.75 cm in variant 3. Conclusion: The three common variants (1, 2 and 3) are the most relevant ones. 14.4 % of patients had different anatomic variants. The variability of the mesenteric venous system was higher than previously published. Knowledge of rare variants is important to avoid complications in abdominal surgery. (orig.)

  14. Treatment of chronic portal--systemic encephalopathy with vegetable and animal protein diets. A controlled crossover study.

    Science.gov (United States)

    Uribe, M; Márquez, M A; Garcia Ramos, G; Ramos-Uribe, M H; Vargas, F; Villalobos, A; Ramos, C

    1982-12-01

    A controlled crossover clinical comparison of 40-g/day and 80-g/day vegetable protein diets vs a 40-g/day meat protein diet plus neomycin-milk of magnesia (as control therapy) was performed on 10 cirrhotic patients with mild chronic portal-systemic encephalopathy. The 40-g vegetable protein diet had a high fiber volume and contained low methionine and low aromatic amino acids. The 80-g vegetable protein diet was rich in branched-chain amino acids and fiber, with a similar content of sulfur-containing amino acids as compared to the 40-g meat protein diet. Serial semiquantitative assessments were done, including mental state, asterixis, number connection tests, electroencephalograms and blood ammonia levels. No patient developed deep coma while ingesting either vegetable protein diet or neomycin-milk of magnesia plus 40-g meat protein diet. A significant improvement in the number connection test times was observed during the 40-g vegetable protein diet (P less than 0.05) and during the 80-g vegetable protein diet (P less than 0.05) as compared to their previous 40-g meat protein--neomycin periods. In addition, during the period of 80-g vegetable protein diet, the patients showed a significant improvement in their electroencephalograms (P less than 0.05). The frequency of bowel movements significantly increased (P less than 0.05) during the 80-g vegetable protein diet period. During the 40-g vegetable protein diet, two cirrhotic--diabetic patients experienced hypoglycemia. Three patients complained of the voluminous 80-g vegetable protein diet. Patients with mild portal--systemic encephalopathy may be adequately controlled with vegetable protein diets as a single therapy.

  15. [Application of degree of portal systemic shunting in assessing upper gastrointestinal bleeding in patients with schistosomiasis cirrhosis].

    Science.gov (United States)

    Shuai, Ju; Ying, Li; Chang-Xue, Ji; Biao, Zhang

    2017-03-27

    To discuss the application of the degree of portal systemic shunting in assessing the upper gastrointestinal bleeding in patients with hepatic schistosomiasis. Thirty-three patients with upper gastrointestinal bleeding caused by hepatic schistosomiasis (a bleeding group) and 29 schistosomiasis cirrhosis patients without bleeding (a non-bleeding group) were enrolled as investigation subjects in Jinshan Hospital. The subjects were scanned by the 128 abdominal slice spiral CT. The portal systemic shunting vessels were reconstructed by using thin slab maximum intensity projection (TSMIP) and multiplanar reconstruction (MPR). The degrees of the shunting vessels of the subjects were evaluated and compared, and the relationship between upper gastrointestinal bleeding and the degree of the shunting was analyzed. In the bleeding group, the occurrence rates of the shunting vessels were found as follows: 86.4% in left gastric varices, 68.2% in short gastric varices, 50.0% in esophageal varices, 50.0% in para-esophageal varices, 37.9% in gastric varices, 69.7% in gastric-renal varices, 51.5% in spleen-renal varices, 25.8% in abdominal wall varices, 15.2% in omentum varices, 63.6% in para-splenic varices, 34.8% in umbilical varices, 40.9% in retroperitoneal-paravertebral varices, and 36.4% in mesenteric varices. In the bleeding group, the occurrence rates and the degree of shunt were significantly higher than those in the non-bleeding group in esophageal varices, esophageal vein, left gastric vein and gastric varices (all P upper gastrointestinal bleeding in patients with hepatic schistosomiasis. The patents with higher degree of the shunting vessels have a higher risk of gastrointestinal bleeding.

  16. Effect of dietary fructose on portal and systemic serum fructose levels in rats and in KHK−/− and GLUT5−/− mice

    Science.gov (United States)

    Patel, Chirag; Sugimoto, Keiichiro; Douard, Veronique; Shah, Ami; Inui, Hiroshi; Yamanouchi, Toshikazu

    2015-01-01

    Elevated blood fructose concentrations constitute the basis for organ dysfunction in fructose-induced metabolic syndrome. We hypothesized that diet-induced changes in blood fructose concentrations are regulated by ketohexokinase (KHK) and the fructose transporter GLUT5. Portal and systemic fructose concentrations determined by HPLC in wild-type mice fed for 7 days 0% free fructose were fructose levels, however, increased markedly in those fed isocaloric 20% fructose, causing significant hyperglycemia. Deletion of KHK prevented fructose-induced hyperglycemia, but caused dramatic hyperfructosemia (>1 mM) with reversed portal to systemic gradients. Systemic fructose in wild-type and KHK−/− mice changed by 0.34 and 1.8 mM, respectively, for every millimolar increase in portal fructose concentration. Systemic glucose varied strongly with systemic, but not portal, fructose levels in wild-type, and was independent of systemic and portal fructose in KHK−/−, mice. With ad libitum feeding for 12 wk, fructose-induced hyperglycemia in wild-type, but not hyperfructosemia in KHK−/− mice, increased HbA1c concentrations. Increasing dietary fructose to 40% intensified the hyperfructosemia of KHK−/− and the fructose-induced hyperglycemia of wild-type mice. Fructose perfusion or feeding in rats also caused duration- and dose-dependent hyperfructosemia and hyperglycemia. Significant levels of blood fructose are maintained independent of dietary fructose, KHK, and GLUT5, probably by endogenous synthesis of fructose. KHK prevents hyperfructosemia and fructose-induced hyperglycemia that would markedly increase HbA1c levels. These findings explain the hyperfructosemia of human hereditary fructosuria as well as the hyperglycemia of fructose-induced metabolic syndrome. PMID:26316589

  17. Idiopathic non-cirrhotic portal hypertension

    Directory of Open Access Journals (Sweden)

    CHEN Jie

    2013-07-01

    Full Text Available The pathogenesis of idiopathic non-cirrhotic portal hypertension (INCPH remains unknown and the disease is diagnosed by the absence of recognized clinical indicators of cirrhosis and of any other known etiologies of portal hypertension. To promote understanding of this disease, a comprehensive overview of potential etiologies, clinical manifestations, histopathological features, methods of diagnosis and potential differential diagnoses, and outcome of clinical management is presented in this review. In particular, we discuss the findings from INCPH studies and their implications in regards to each of the above-mentioned categories. For example, associations with various comorbidities have suggested a possible immune system component to INCPH development and/or progression. In addition, the common clinical characteristics of patients upon presentation can not only help to recognize disease suspects but may also provide insights into the pathogenesis and prognosis. Finally, prognosis following the various intervention strategies appears to depend mainly on severity of the portal hypertension, as well as its various accompanying complications.

  18. The influence of culture on enterprise portal design in a global environment

    NARCIS (Netherlands)

    Feng, Xiuzhen; Ehrenhard, Michel Léon; Hicks, Jeff; Hou, Yibin; Khosrow-Pour, M.

    2007-01-01

    Enterprise portals collect and synthesize information from various systems to deliver personalized and highly relevant information to suppliers, customers and employees. While enterprise portal design and portal applications have been widely discussed in the literature, the implications that arise

  19. Noncirrhotic portal fibrosis after Wilms' tumor therapy

    International Nuclear Information System (INIS)

    Barnard, J.A.; Marshall, G.S.; Neblett, W.W.; Gray, G.; Ghishan, F.K.

    1986-01-01

    A 9-yr-old girl developed massive hemorrhage from esophageal varices 2 yr after combined modality therapy for Wilms' tumor. Evaluation showed a patent extrahepatic portal venous system and an elevated splenic pulp pressure. In contrast to previous reports of hepatopathy after irradiation injury, histologic sections of the liver did not demonstrate occlusion of the central veins, but rather a diffuse obliteration of intrahepatic portal venous radicles. This pattern of noncirrhotic portal fibrosis has not been described following antitumor therapy

  20. Extrahepatic portal venous system thrombosis in recurrent acute and chronic alcoholic pancreatitis is caused by local inflammation and not thrombophilia.

    Science.gov (United States)

    Rebours, Vinciane; Boudaoud, Larbi; Vullierme, Marie-Pierre; Vidaud, Dominique; Condat, Bertrand; Hentic, Olivia; Maire, Frédérique; Hammel, Pascal; Ruszniewski, Philippe; Lévy, Philippe

    2012-10-01

    Extrahepatic portal venous system thrombosis (EPVST) occurs in 13% of patients with either recurrent acute (AP) or chronic (CP) alcoholic pancreatitis. The role of thrombophilia has never been assessed in this entity. All consecutive patients with alcoholic AP or CP were included in a prospective study. All patients underwent a computerized tomography (CT) scan of the pancreas to evaluate EPVST as well as thorough testing for thrombophilia (protein C, S, and antithrombin deficiency, factor II, factor V, and JAK2 gene mutations, homocystein, biological antiphospholipid syndrome). A total of 119 patients (male, n=100 (84%); smokers, n=110 (92%)) were included. EPVST was found in 41 patients (35%). The portal, superior mesenteric, or splenic veins were involved in 34%, 24%, and 93% of patients, respectively. Thrombophilia was identified in 18% (n=22), including the biological antiphospholipid syndrome, factor V Leiden mutation, and factor II G20210A gene mutation in 21 (17.6%), 2 (1.6%), and 1 patient (0.8%), respectively. On univariate analysis, the factors associated with EPVST were smoking (RR=1.6 (1.38-1.85), P=0.03), pseudocysts (RR=2.91 (1.29-6.56), P=0.008), a pseudocyst in the pancreatic tail (P=0.03), a high CT severity index for AP (P=0.007), and pancreatic parenchymal necrosis (P=0.02). The presence of hemostatic risk factors was not associated with an increased risk of EPVST. On multivariate analysis, only pseudocysts were associated with EPVST (hazard ratio: 6.402; 95% confidence interval (1.59-26.54), P=0.009). EPVST is found in 35% of patients with acute/chronic alcoholic pancreatitis. Local inflammation appears to be the major predisposing condition. The presence of some form of thrombophilia does not increase the risk of EPVST and should not be systematically searched for in case of EPVST.

  1. Idiopathic portal hypertension

    International Nuclear Information System (INIS)

    Han, Tae Kyun; Ryu, Dae Sik; Kim, Heung Chul; Hur, Hun; Eom, Kyeung Tae; Namkung, Sook; Park, Man Soo; Hwang, Woo Chul; Lee, Kwan Seop

    1996-01-01

    To describe the radiologic findings of idiopathic portal hypertension and to find the points of differentiation between idiopathic portal hypertension and liver cirrhosis. Four portograms in five patients who for four years had suffered from pathologically confirmed idiopathic portal hypertension were retrospectively analyzed and compared with a portogram obtained from a control subject with liver cirrhosis. Portographic finding s of idiopathic portal hypertension were paucity of medium-sized portal branches, irregular and obtuse-angled division of peripheral branches, abrupt interruption and an avascular area beneath the liver margin. A portogram of idiopathic portal hypertension may be useful in differentiation this and liver cirrhosis

  2. Rare Disease Video Portal

    OpenAIRE

    Sánchez Bocanegra, Carlos Luis

    2011-01-01

    Rare Disease Video Portal (RD Video) is a portal web where contains videos from Youtube including all details from 12 channels of Youtube. Rare Disease Video Portal (RD Video) es un portal web que contiene los vídeos de Youtube incluyendo todos los detalles de 12 canales de Youtube. Rare Disease Video Portal (RD Video) és un portal web que conté els vídeos de Youtube i que inclou tots els detalls de 12 Canals de Youtube.

  3. Advanced Portal Images Processing for Cobalt Radiotherapy Systems and Lineal Accelerator for cancer treatment

    International Nuclear Information System (INIS)

    Valdes Cabrera, D.

    2013-01-01

    It is presented an investigation project to design software that allows image processing and treatment of an Electronic Portal Image Device (EPID) for lineal accelerators and cobalt machines. For the development of the software it was used the programming language MATLAB and DICOM RT images with a spatial resolution in the isocenter of 0.40 mm/pixel, dimensions of 1024x1024 pixels and 65536 tones in grey scale, that were taken by a linac from Elekta trademark located in the National Institute of Oncology and Radiobiology. Methods and algorithms implemented were the improvements in the contrast, brightness, equalization and inversion of grey scale of images through modifications in their histogram; the possibility of making rotations, segmentations of zones of interest basing in users criteria for thresholding taking in count the visualization of pixels intensity and measuring of distances in pixels. For the calculations of displacements and rotations between the reference and the actual image was used the canny method for edges detection of the radiation fields and anatomical structures, and normalized bidimensional correlation algorithms for seeking and calculation of objects of interest between two images. The results were obtained using 23 pairs of images of six treatments and the average of the reported errors were: horizontal, vertical and rotational fields errors: ± .531 mm, ± 1.278 mm and ± 0.087 o ; horizontal, vertical and rotational anatomical structures errors: ± 0.766 mm, ± 0.573 mm, ± 0.174 o . these values are under the limit values for each one of these treatments according to the consulted bibliography. (Author)

  4. Development of Final Running Test System for Digital Systems

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok

    2016-01-01

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed

  5. Development of Final Running Test System for Digital Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed.

  6. The Knowledge Portal

    Data.gov (United States)

    Office of Personnel Management — Information on various courses, as well as personal data of employees and training records from The Knowledge Portal (TKP), a web-based training portal used for the...

  7. Regional blood flows by the microsphere method: reproducibility in portal hypertensive rats and influence of a portal vein catheter

    International Nuclear Information System (INIS)

    Hadengue, A.; Lee, S.S.; Koshy, A.; Girod, C.; Lebrec, D.

    1988-01-01

    To determine the reproducibility of splanchnic blood flow measurements by the microsphere method in rats with portal hypertension and the effects of laparotomy with portal vein cannulation, eight groups of 10 rats were studied. Microspheres were labelled with 113 Sn or 141 Ce. Laparotomy with portal cannulation had no significant effect in sham-operated rats. In awake portal hypertensive rats, cardiac output and splanchnic blood flow were lower in portal vein cannulated rats compared with those of non-cannulated animals. In anesthetized portal hypertensive rats blood flows were unaffected by portal cannulation, but arterial pressure and heart rate were elevated. Anesthesia also decreased portal pressure in portal hypertensive rats. We conclude that the microsphere method remains reproducible in portal hypertensive rat models. Laparotomy with portal cannulation can alter systemic and splanchnic hemodynamics in portal hypertensive rats; these effects can also be changed during pentobarbital anesthesia. Regional blood flow measurements in portal hypertensive rats should be performed in animals without portal cannulation and preferably in the awake state

  8. Usability of Discovery Portals

    NARCIS (Netherlands)

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals

  9. Portals people, processes, technology

    CERN Document Server

    Cox, Andrew

    2006-01-01

    First applied to internet gateways such as Yahoo, the concept of the ""portal"" has evolved in a number of directions. How can information services best take advantage of internet portals to improve access to resources? This collection seeks answers to such questions, providing an overview of how portals are being used.

  10. The feasible study of vasodilators in portal vein targeting infusion for treating portal hypertension

    International Nuclear Information System (INIS)

    Wu Hanping; Liang Huiming; Zheng Chuansheng; Feng Gansheng

    2002-01-01

    Objective: To find out the ideal portal vein tar getting injection routes for portal hypertension treatment. Methods: 28 cirrhotic rat models with portal hypertension induced by CCl 4 were divided into 4 groups: inferior caval vein injection group, portal vein injection group, hepatic artery injection group, spleen injection group. The changes in portal vein pressure (PVP), inferior caval vein pressure (ICVP), mean artery pressure (MAP) and heart rate (HR) were monitored before and after prazosin injection. Results: After intra-portal, intra-hepatic arterial or spleen injection of prazosin, larger decrease in PVP and lesser effects on MAP than intravenous injection had been induced. The effect on HR showed no difference among these four groups. Conclusions: Hepatic artery and spleen prazosin administration have the same advantages on treatment of portal hypertension as those of intra-portal infusion, that is the greater decrease on portal vein pressure, the lesser effects on systemic hemodynamics. Vasodilation drugs for hepatic artery infusion through percutaneous port catheter system by hepatic artery implantation would be an ideal method for portal hypertension treatment

  11. Fundamental factors influencing portal image quality

    International Nuclear Information System (INIS)

    Jaffray, D.A.

    1995-01-01

    It has been recognized that improved methods of verifying radiation field placement in external beam radiotherapy are required in order to make frequent checks of field placement feasible. As a result, a large number of electronic portal imaging systems have been developed as possible replacements for film. These developments have produced digital systems with faster acquisition and improved display contrast, however, the quality of the images acquired with such systems is still disappointing. This presentation examines many of the fundamental factors which limit the quality of radiographs obtained with a megavoltage radiotherapy beam. The size and shape of the radiation sources (focal and extra-focal) in radiotherapy machines and their influence on the spatial resolution of portal images are examined. Monte Carlo simulations of x-ray interactions within the patient determined that a significant fraction of the x-ray scatter generated in the patient is due to bremsstrahlung and positron annihilation. Depending on the detector, the scatter signal can reduce the differential signal-to-noise by 20%. Furthermore, a Monte Carlo study of the interaction of x-rays within typical fluoroscopic imaging detectors (metal plate/phosphor screen) demonstrates the degrading effect of energy absorption noise on the detective quantum efficiency of fluoroscopic based imaging systems. Finally, the spatial frequency content in the x-ray shadowgram is demonstrated to change with x-ray energy, resulting in images that appear to have reduced spatial resolution at megavoltage energies. The relative magnitude of each of these factors will be presented and recommendations for the next generation of portal imaging systems will be made

  12. Veias do sistema porta-hepático em gansos domésticos Veins from hepatic portal vein system in domestic geese

    Directory of Open Access Journals (Sweden)

    Tatiana C. Santos

    2009-04-01

    hepatic lobe, connected by a parenchyma bridge. The right hepatic lobe had vessels exclusively from the hepatic portal system composed by intraparenchymal distribution of the right hepatic portal vein, while the vessels of the left hepatic lobe came from the right hepatic portal vein and from small left hepatic portal veins. The right hepatic portal vein emitted the right caudal branch, which emitted a small right caudolateral branch and a large right caudomedial branch. Cranially this vein emitted right cranial and right lateral branches. The tranverse portion of the right hepatic portal vein crossed to the left hepatic lobe, emitting 1 to 6 small cranial and caudal branches to the medial area of the liver. In the left hepatic lobe, the left branch from the right hepatic vein emitted the left cranial, left lateral and left median branches. One to six left hepatic portal veins were identified arising from the left branch or from the transverse portion of the right hepatic portal vein. These vessels arose from the gizzard and pro-ventricle. In 40% of geese one proper hepatic portal vein originated from venous vessels of the gizzard and was distributed into the caudal extremity of the left hepatic isolated lobe.

  13. Portal hypertensiv gastropati

    DEFF Research Database (Denmark)

    Brinch, K; Møller, S; Henriksen, Jens Henrik Sahl

    1995-01-01

    Portal hypertensive gastropathy (PHG) as defined by congestive changes in the gastric mucosa owing to increased portal pressure, was first described about ten years ago. Whereas definition and grading of severity are still under debate, there is general agreement that PHG is a new clinical entity....... PHG is present in 50-80% of patients with liver cirrhosis. PHG is a major cause of upper gastrointestinal bleeding in patients with portal hypertension (25-90% depending on severity). Presence of portal hypertension is a prerequisite for the development of PHG, and reduction of portal pressure...

  14. Mobile Portal Implementation Strategy

    DEFF Research Database (Denmark)

    Gao, Ping; Damsgaard, Jan

    2005-01-01

    Mobile portal plays an important role in mobile commerce market. Current literature focuses on static analysis on the value chain of mobile portals. This article provides a dynamic perspective on mobile portal strategy. Drawing upon network economics, we describe mobile portal implementation...... as a fourphase process. In different phase, a portal provider has various challenges to overcome and adopt diverse strategies, and correspondingly the regulator has different foci. The conceptual framework proposed in this article offers a basis for further analyses on the market dynamics of mobile commerce......, and can be generalized to studying other networked technologies...

  15. Liquid waste treatment system. Final report

    International Nuclear Information System (INIS)

    Baker, M.N.; Houston, H.M.

    1999-01-01

    Pretreatment of high-level liquid radioactive waste (HLW) at the West Valley Demonstration Project (WVDP) involved three distinct processing operations: decontamination of liquid HLW in the Supernatant Treatment System (STS); volume reduction of decontaminated liquid in the Liquid Waste Treatment System (LWTS); and encapsulation of resulting concentrates into an approved cement waste form in the Cement Solidification System (CSS). Together, these systems and operations made up the Integrated Radwaste Treatment System (IRTS)

  16. Chromatic correction for the final transport system

    International Nuclear Information System (INIS)

    Brown, K.L.; Peterson, J.M.

    1980-01-01

    The final transport and focusing of the heavy-ion beam onto the fusion pellet in vacuum is complicated by several non-linear effects - namely, chromatic (momentum dependent) effects, geometric aberrations, and space-charge forces. This paper gives an example of how the chromatic effects can be nullified, at least to second order. Whether third- or higher-order terms are important is not yet clear. Space-charge effects are important but are not considered here

  17. User Needs of Digital Service Web Portals: A Case Study

    Science.gov (United States)

    Heo, Misook; Song, Jung-Sook; Seol, Moon-Won

    2013-01-01

    The authors examined the needs of digital information service web portal users. More specifically, the needs of Korean cultural portal users were examined as a case study. The conceptual framework of a web-based portal is that it is a complex, web-based service application with characteristics of information systems and service agents. In…

  18. Schistosoma mansoni: quantitative aspects of the evolution of gamma-radiation cercariae at the skin, lungs and portal system, in mice

    International Nuclear Information System (INIS)

    Sa Cardoso, G. de; Coelho, P.M.Z.

    1989-01-01

    The migration of Schistosoma mansoni (LE and SJ strains) has been studied in eight groups of outbred Swiss albino mice (Mus musculus), which were previously infected with ca 450 cercariae, trans-cutaneously. The infection of mice was performed with non irradiated cercariae (control groups), or with gamma-irradiated cercariae, at the schedule of 3, 20 and 40 Krad. Regarding the skin, a progressive decrease was detected for the recovery rates, related to the time of infection. As far as the lungs and portal system are concerned, a significant inverse correlation was observed between the total recovery rate and the irradiation dosages. The dose of 20 Krad practically hinders the migration of the parasites (in both strains) from the lungs to the portal system, whereas the dose of 40 Krad prevents the migration of most of the parasites from the skin to the lungs. (author)

  19. LANL environmental restoration site ranking system: System description. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Merkhofer, L.; Kann, A.; Voth, M. [Applied Decision Analysis, Inc., Menlo Park, CA (United States)

    1992-10-13

    The basic structure of the LANL Environmental Restoration (ER) Site Ranking System and its use are described in this document. A related document, Instructions for Generating Inputs for the LANL ER Site Ranking System, contains detailed descriptions of the methods by which necessary inputs for the system will be generated. LANL has long recognized the need to provide a consistent basis for comparing the risks and other adverse consequences associated with the various waste problems at the Lab. The LANL ER Site Ranking System is being developed to help address this need. The specific purpose of the system is to help improve, defend, and explain prioritization decisions at the Potential Release Site (PRS) and Operable Unit (OU) level. The precise relationship of the Site Ranking System to the planning and overall budget processes is yet to be determined, as the system is still evolving. Generally speaking, the Site Ranking System will be used as a decision aid. That is, the system will be used to aid in the planning and budgetary decision-making process. It will never be used alone to make decisions. Like all models, the system can provide only a partial and approximate accounting of the factors important to budget and planning decisions. Decision makers at LANL will have to consider factors outside of the formal system when making final choices. Some of these other factors are regulatory requirements, DOE policy, and public concern. The main value of the site ranking system, therefore, is not the precise numbers it generates, but rather the general insights it provides.

  20. LANL environmental restoration site ranking system: System description. Final report

    International Nuclear Information System (INIS)

    Merkhofer, L.; Kann, A.; Voth, M.

    1992-01-01

    The basic structure of the LANL Environmental Restoration (ER) Site Ranking System and its use are described in this document. A related document, Instructions for Generating Inputs for the LANL ER Site Ranking System, contains detailed descriptions of the methods by which necessary inputs for the system will be generated. LANL has long recognized the need to provide a consistent basis for comparing the risks and other adverse consequences associated with the various waste problems at the Lab. The LANL ER Site Ranking System is being developed to help address this need. The specific purpose of the system is to help improve, defend, and explain prioritization decisions at the Potential Release Site (PRS) and Operable Unit (OU) level. The precise relationship of the Site Ranking System to the planning and overall budget processes is yet to be determined, as the system is still evolving. Generally speaking, the Site Ranking System will be used as a decision aid. That is, the system will be used to aid in the planning and budgetary decision-making process. It will never be used alone to make decisions. Like all models, the system can provide only a partial and approximate accounting of the factors important to budget and planning decisions. Decision makers at LANL will have to consider factors outside of the formal system when making final choices. Some of these other factors are regulatory requirements, DOE policy, and public concern. The main value of the site ranking system, therefore, is not the precise numbers it generates, but rather the general insights it provides

  1. Design of a New Collimation System to Prevent Interference between X-ray Machines and Radiation Portal Monitors

    International Nuclear Information System (INIS)

    Guzzardo, Tyler; Livesay, Jake

    2012-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) developed a new collimation system that allows radiation portal monitors (RPMs) installed near x-ray machines to operate with a negligible false-positive alarm rate. RPMs are usually installed as far as possible from x-ray machines because false alarms are triggered by escaping x-rays; however, constraints at the installation site sometimes make it necessary that RPMs be installed near x-ray machines. Such RPMs are often plagued by high alarm rates resulting from the simultaneous operation of the RPMs and x-ray machines. Limitations on pedestrian flow, x-ray machine orientation, and RPM location often preclude a simple solution for lowering the alarm rate. Adding additional collimation to the x-ray machines to stop the x-rays at the source can reduce the alarm rate without interfering with site operations or adversely affecting the minimum detectable quantity of material (MDQ). A collimation design has been verified by measurements conducted at a RPM installation site and is applicable to all new and existing RPM installations near x-ray machines.

  2. Nuclear Accidents Archive Knowledge Organization System Portal “NAAKOS”: An Application of Semantic Technologies in the Nuclear Domain

    International Nuclear Information System (INIS)

    Atieh, T.

    2016-01-01

    Full text: In line with the IAEA Action Plan on Nuclear Safety, the IAEA was requested to assist Member States enhancing transparency and effectiveness of communication among operators, regulators and various international organizations, and supporting wide dissemination of safety related technical information on nuclear safety. In this context, the IAEA was further asked to analyse and preserve lessons learned from the Fukushima Daiichi NPP accident, as well as from past major incidents and radiological events. The IAEA NKM Section has launched the Nuclear Accidents Repository Portal Knowledge Organization System “NAAKOS” initiative which aims at collecting and preserving data, information, and knowledge related to nuclear accidents and making this knowledge available through one single access point, while ensuring their long term preservation. The NKM Section has developed the Nuclear Accidents Taxonomy which will be used, along other nuclear taxonomies, to enhance information retrieval. It would also include the use of semantic technologies, data mining and linked data to support users beyond the traditional search facilities. The overall objective is to assist to find predefined measures in a timely manner that could prevent, or at least minimize the adverse effects of incidents. (author

  3. The Protein Model Portal.

    Science.gov (United States)

    Arnold, Konstantin; Kiefer, Florian; Kopp, Jürgen; Battey, James N D; Podvinec, Michael; Westbrook, John D; Berman, Helen M; Bordoli, Lorenza; Schwede, Torsten

    2009-03-01

    Structural Genomics has been successful in determining the structures of many unique proteins in a high throughput manner. Still, the number of known protein sequences is much larger than the number of experimentally solved protein structures. Homology (or comparative) modeling methods make use of experimental protein structures to build models for evolutionary related proteins. Thereby, experimental structure determination efforts and homology modeling complement each other in the exploration of the protein structure space. One of the challenges in using model information effectively has been to access all models available for a specific protein in heterogeneous formats at different sites using various incompatible accession code systems. Often, structure models for hundreds of proteins can be derived from a given experimentally determined structure, using a variety of established methods. This has been done by all of the PSI centers, and by various independent modeling groups. The goal of the Protein Model Portal (PMP) is to provide a single portal which gives access to the various models that can be leveraged from PSI targets and other experimental protein structures. A single interface allows all existing pre-computed models across these various sites to be queried simultaneously, and provides links to interactive services for template selection, target-template alignment, model building, and quality assessment. The current release of the portal consists of 7.6 million model structures provided by different partner resources (CSMP, JCSG, MCSG, NESG, NYSGXRC, JCMM, ModBase, SWISS-MODEL Repository). The PMP is available at http://www.proteinmodelportal.org and from the PSI Structural Genomics Knowledgebase.

  4. Building an Archival Collections Portal

    Directory of Open Access Journals (Sweden)

    Stuart Marquis

    2008-06-01

    Full Text Available Columbia University Libraries has developed the Archival Collections Portal, a unified search system helping users discover archival resources in a streamlined way. We combined the power of Lucene and Solr to search XML, parse JSON objects, create EAD-compliant documents, and deliver results in an easy-to-use interface. By reusing MARC records and employing new search engine features and techniques, we are able to bring important and hard-to-find collections to researchers and archivists. The canonical home page of the Portal is http://www.columbia.edu/library/archival/.

  5. Solar thermal repowering systems integration. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dubberly, L. J.; Gormely, J. E.; McKenzie, A. W.

    1979-08-01

    This report is a solar repowering integration analysis which defines the balance-of-plant characteristics and costs associated with the solar thermal repowering of existing gas/oil-fired electric generating plants. Solar repowering interface requirements for water/steam and salt or sodium-cooled central receivers are defined for unit sizes ranging from 50 MWe non-reheat to 350 MWe reheat. Finally balance-of-plant cost estimates are presented for each of six combinations of plant type, receiver type and percent solar repowering.

  6. Photovoltaic systems concept study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1977-04-01

    The work performed in the conceptual design and systems analysis of three sizes of photovoltaic solar electric power systems is contained in five volumes consisting of nine sections plus appendices. Separate abstracts were prepared for the two sections in this volume. (MHR)

  7. The organizational dynamics enabling patient portal impacts upon organizational performance and patient health: a qualitative study of Kaiser Permanente.

    Science.gov (United States)

    Otte-Trojel, Terese; Rundall, Thomas G; de Bont, Antoinette; van de Klundert, Joris; Reed, Mary E

    2015-12-16

    Patient portals may lead to enhanced disease management, health plan retention, changes in channel utilization, and lower environmental waste. However, despite growing research on patient portals and their effects, our understanding of the organizational dynamics that explain how effects come about is limited. This paper uses qualitative methods to advance our understanding of the organizational dynamics that influence the impact of a patient portal on organizational performance and patient health. The study setting is Kaiser Permanente, the world's largest not-for-profit integrated delivery system, which has been using a portal for over ten years. We interviewed eighteen physician leaders and executives particularly knowledgeable about the portal to learn about how they believe the patient portal works and what organizational factors affect its workings. Our analytical framework centered on two research questions. (1) How does the patient portal impact care delivery to produce the documented effects?; and (2) What are the important organizational factors that influence the patient portal's development? We identify five ways in which the patient portal may impact care delivery to produce reported effects. First, the portal's ability to ease access to services improves some patients' satisfaction as well as changes the way patients seek care. Second, the transparency and activation of information enable some patients to better manage their care. Third, care management may also be improved through augmented patient-physician interaction. This augmented interaction may also increase the 'stickiness' of some patients to their providers. Forth, a similar effect may be triggered by a closer connection between Kaiser Permanente and patients, which may reduce the likelihood that patients will switch health plans. Finally, the portal may induce efficiencies in physician workflow and administrative tasks, stimulating certain operational savings and deeper involvement of

  8. Proximity sensor system development. CRADA final report

    International Nuclear Information System (INIS)

    Haley, D.C.; Pigoski, T.M.

    1998-01-01

    Lockheed Martin Energy Research Corporation (LMERC) and Merritt Systems, Inc. (MSI) entered into a Cooperative Research and Development Agreement (CRADA) for the development and demonstration of a compact, modular proximity sensing system suitable for application to a wide class of manipulator systems operated in support of environmental restoration and waste management activities. In teleoperated modes, proximity sensing provides the manipulator operator continuous information regarding the proximity of the manipulator to objects in the workspace. In teleoperated and robotic modes, proximity sensing provides added safety through the implementation of active whole arm collision avoidance capabilities. Oak Ridge National Laboratory (ORNL), managed by LMERC for the United States Department of Energy (DOE), has developed an application specific integrated circuit (ASIC) design for the electronics required to support a modular whole arm proximity sensing system based on the use of capacitive sensors developed at Sandia National Laboratories. The use of ASIC technology greatly reduces the size of the electronics required to support the selected sensor types allowing deployment of many small sensor nodes over a large area of the manipulator surface to provide maximum sensor coverage. The ASIC design also provides a communication interface to support sensor commands from and sensor data transmission to a distributed processing system which allows modular implementation and operation of the sensor system. MSI is a commercial small business specializing in proximity sensing systems based upon infrared and acoustic sensors

  9. Proximity sensor system development. CRADA final report

    Energy Technology Data Exchange (ETDEWEB)

    Haley, D.C. [Oak Ridge National Lab., TN (United States); Pigoski, T.M. [Merrit Systems, Inc. (United States)

    1998-01-01

    Lockheed Martin Energy Research Corporation (LMERC) and Merritt Systems, Inc. (MSI) entered into a Cooperative Research and Development Agreement (CRADA) for the development and demonstration of a compact, modular proximity sensing system suitable for application to a wide class of manipulator systems operated in support of environmental restoration and waste management activities. In teleoperated modes, proximity sensing provides the manipulator operator continuous information regarding the proximity of the manipulator to objects in the workspace. In teleoperated and robotic modes, proximity sensing provides added safety through the implementation of active whole arm collision avoidance capabilities. Oak Ridge National Laboratory (ORNL), managed by LMERC for the United States Department of Energy (DOE), has developed an application specific integrated circuit (ASIC) design for the electronics required to support a modular whole arm proximity sensing system based on the use of capacitive sensors developed at Sandia National Laboratories. The use of ASIC technology greatly reduces the size of the electronics required to support the selected sensor types allowing deployment of many small sensor nodes over a large area of the manipulator surface to provide maximum sensor coverage. The ASIC design also provides a communication interface to support sensor commands from and sensor data transmission to a distributed processing system which allows modular implementation and operation of the sensor system. MSI is a commercial small business specializing in proximity sensing systems based upon infrared and acoustic sensors.

  10. Hipertensão portal por esquistossomose mansônica hepatoesplênica: efeito da desconexão ázigo-portal com esplenectomia no diâmetro e na velocidade média de fluxo do sistema portal (estudo ultra-sonográfico com Doppler Hepatosplenic schistosomotic portal hypertension: effect of esophagogastric devascularization with splenectomy on the diameter and mean flow velocity in the portal system (ultra-sonographic Doppler study

    Directory of Open Access Journals (Sweden)

    Azzo WIDMAN

    2001-01-01

    Full Text Available Racional - A esplenectomia com desconexão ázigo-portal tem sido indicada para o tratamento da hemorragia digestiva pelas varizes esofágicas na hipertensão portal da esquistossomose mansônica hepatoesplênica. Todavia, esta técnica terapêutica apresenta índices variáveis de complicações trombóticas precoces do sistema portal (13,3% a 53,2%. Supondo que as alterações circulatórias devidas ao tratamento cirúrgico tenham papel preponderante neste acontecimento, procurou-se identificar elementos hemodinâmicos que, dentre os múltiplos fatores causais, tenham facilitado a ocorrência desta complicação. Com este intuito estudou-se comparativamente, mediante ultra-sonografia com Doppler, o sistema portal de dois grupos de pacientes em condições clínicas semelhantes: não-operados e com desconexão ázigo-portal em fase pós-operatória tardia (período superior a 6 meses. Casuística/Método - Foram estudados 58 pacientes com esquistossomose mansônica hepatoesplênica e com antecedentes de hemorragia digestiva alta, divididos em dois grupos: A (29 sob controle ambulatorial: clínico e endoscópico; B (29 submetidos previamente a desconexão ázigo-portal. Em todos foi feita a medida do diâmetro e da velocidade média de fluxo do sangue na veia porta e seus ramos direito e esquerdo, mediante ultra-sonografia com Doppler. Os resultados foram submetidos a análise univariada inter e intragrupo. Resultados - No grupo A (não-operados: a veia porta apresentou diâmetro maior do que o dos ramos direito e esquerdo e nestes esta medida foi semelhante (10,6 ± 2,9, 8,0 ± 1,8, 9,1 ± 2,6 cm; a velocidade média de fluxo na veia porta e nos ramos portais foi semelhante (15,62 ± 6,17, 14,92 ± 5,33, 16,12 ± 4,18 cm/seg. No grupo B (operados: houve diminuição de ambos os parâmetros na veia porta e seus ramos (8,8 ± 1,7, 5,2 ± 1,2, 7,5 ± 2,2 cm/12,53 ± 2,60, 8,86 ± 1,75, 9,60 ± 3,75 cm/seg. Conclusões - Houve redu

  11. Solar radiation alert system : final report.

    Science.gov (United States)

    2009-03-01

    The Solar Radiation Alert (SRA) system continuously evaluates measurements of high-energy protons made by instruments on GOES satellites. If the measurements indicate a substantial elevation of effective dose rates at aircraft flight altitudes, the C...

  12. Intelligent Transportation Systems statewide architecture : final report.

    Science.gov (United States)

    2003-06-01

    This report describes the development of Kentuckys Statewide Intelligent Transportation Systems (ITS) Architecture. The process began with the development of an ITS Strategic Plan in 1997-2000. A Business Plan, developed in 2000-2001, translated t...

  13. Traffic Management Systems Performance Measurement: Final Report

    OpenAIRE

    Banks, James H.; Kelly, Gregory

    1997-01-01

    This report documents a study of performance measurement for Transportation Management Centers (TMCs). Performance measurement requirements were analyzed, data collection and management techniques were investigated, and case study traffic data system improvement plans were prepared for two Caltrans districts.

  14. Water-storage-tube systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemker, P.

    1981-12-24

    Passive solar collection/storage/distribution systems were surveyed, designed, fabricated, and mechanically and thermally tested. The types studied were clear and opaque fiberglass tubes, metal tubes with plastic liners, and thermosyphoning tubes. (MHR)

  15. PV Systems Reliability Final Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Armijo, Kenneth Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Yang, Benjamin Bing-Yeh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.

  16. Analysis of Hybrid Hydrogen Systems: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Dean, J.; Braun, R.; Munoz, D.; Penev, M.; Kinchin, C.

    2010-01-01

    Report on biomass pathways for hydrogen production and how they can be hybridized to support renewable electricity generation. Two hybrid systems were studied in detail for process feasibility and economic performance. The best-performing system was estimated to produce hydrogen at costs ($1.67/kg) within Department of Energy targets ($2.10/kg) for central biomass-derived hydrogen production while also providing value-added energy services to the electric grid.

  17. Final report on the FMIT Control System

    International Nuclear Information System (INIS)

    Johnson, J.A.

    1985-01-01

    The computer control system for the Fusion Materials Irradiation Test Facility (FMIT) prototype accelerator was designed using distributed intelligence driven by a distributed database. The system consists of two minicomputers in the central control room and four microcomputers residing in CAMAC crates located near appropriate subsystems of the accelerator. The system uses single vendor hardware as much as practical in an attempt to minimize the maintenance problems. Local control consoles are an integral part of each node computer to provide subsystem check-out. The main console is located in the central control room and permits one-point operation of the complete control system. Automatic surveillance is provided for each data channel by the node computer with out-of-bounds alarms sent to the main console. Report by exception is used for data logging. This control system has been operational for two years. The computers are too heavily loaded and the operator response is slower than desired. A system upgrade to a faster local-area network has been undertaken and is scheduled to be operational by conference time

  18. Radiologic investigation of portal hypertension

    International Nuclear Information System (INIS)

    Becker, C.; Wegmueller, H.

    1993-01-01

    Radiologic evaluation of patients with portal hypertension in the pre- and postoperative period can be done with several non-invasive or invasive imaging modalities which offer complementary information. Doppler-ultrasonography (-US) is the method of choice for initial non-invasive screening as well as for follow-up tests after shunt surgery. The diagnostic information provided by Doppler-US regarding morphology and blood flow in the upper abdominal organs and vessels is sufficient in many instances. Dynamic computed tomography (CT), magnetic resonance tomography (MRT) and recently, magnetic resonance angiography (MRA) are additional non-invasive imaging techniques that may add valuable information if necessary. Conventional angiography is usually performed immediately prior to surgery to demonstrate the vascular morphology. The standard angiographic technique to demonstrate both the arterial and portal venous system is arterioportography (late-phase portography) by means of selective catheterization of the celiac, the splenic, the superior mesenteric or inferior mesenteric arteries. The dose of iodinated contrast material may be reduced by 50% if digital subtraction angiography is used instead of the conventional technique. Inferior venacavography and hepatic venography are indicated in patients with suspected postsinusoidal portal hypertension, e.g. the Budd-Chiari syndrome; hepatic wedge manometry offers valuable information regarding pressure gradients between the portal and systemic venous system prior to shunt surgery. The angiographic access through the inferior vena cava is also used for direct catheterization of surgical porto-caval or spleno-renal shunts for both angiography, manometry and, if necessary, balloon angioplasty. (authors)

  19. Advanced Quasioptical Launcher System. Final Report

    International Nuclear Information System (INIS)

    Neilson, Jeffrey

    2010-01-01

    This program developed an analytical design tool for designing antenna and mirror systems to convert whispering gallery RF modes to Gaussian or HE11 modes. Whispering gallery modes are generated by gyrotrons used for electron cyclotron heating of fusion plasmas in tokamaks. These modes cannot be easily transmitted and must be converted to free space or waveguide modes compatible with transmission line systems.This program improved the capability of SURF3D/LOT, which was initially developed in a previous SBIR program. This suite of codes revolutionized quasi-optical launcher design, and this code, or equivalent codes, are now used worldwide. This program added functionality to SURF3D/LOT to allow creating of more compact launcher and mirror systems and provide direct coupling to corrugated waveguide within the vacuum envelope of the gyrotron. Analysis was also extended to include full-wave analysis of mirror transmission line systems. The code includes a graphical user interface and is available for advanced design of launcher systems.

  20. NKS MOMS. Final report. [Mobile Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    Nilssen, J. [Norwegian Radiation Protection Authority (NRPA) (Norway); Aage, H.K. [Danish Emergency Management Agency (DEMA) (Denmark); Palsson, S.E. [Icelandic Radiation Safety Authority (IRSA) (Iceland)

    2013-02-15

    Mobile car-borne measurement systems are an important asset in early phase emergency response in all Nordic countries. However, through the development of the systems in the different countries, there are considerable differences between the systems developed. This complicates Nordic cooperation and mutual assistance in emergency situations. This project aimed to facilitate harmonization of mobile measurement systems between the Nordic countries. The project focused on harmonizing data formats, information exchange and measurement strategies. Although the work done was funded by each member, the project established a good platform for cooperation which will hopefully continue beyond the scope of the project. A two-day seminar was held in May 2012, where all participants presented the current status (equipment, methods used etc.), in addition to invited speakers presenting development within the field of mobile detection and in situ measurements. Exchange of experiences and information on different measurement systems and practises in use was an important part of the seminar. The seminar was followed up by a small workshop during the REFOX exercise in Lund, Sweden, September 2012. Exchange of measurement data from the exercise was facilitated through a workspace proveded by NRPA as part of the MOMS project. The work done in this project will be presented at the NordEx12 seminar in March 2013. (Author)

  1. Sequencing Information Management System (SIMS). Final report

    Energy Technology Data Exchange (ETDEWEB)

    Fields, C.

    1996-02-15

    A feasibility study to develop a requirements analysis and functional specification for a data management system for large-scale DNA sequencing laboratories resulted in a functional specification for a Sequencing Information Management System (SIMS). This document reports the results of this feasibility study, and includes a functional specification for a SIMS relational schema. The SIMS is an integrated information management system that supports data acquisition, management, analysis, and distribution for DNA sequencing laboratories. The SIMS provides ad hoc query access to information on the sequencing process and its results, and partially automates the transfer of data between laboratory instruments, analysis programs, technical personnel, and managers. The SIMS user interfaces are designed for use by laboratory technicians, laboratory managers, and scientists. The SIMS is designed to run in a heterogeneous, multiplatform environment in a client/server mode. The SIMS communicates with external computational and data resources via the internet.

  2. The final fate of planetary systems

    Science.gov (United States)

    Gaensicke, Boris

    2015-12-01

    The discovery of the first extra-solar planet around a main-sequence star in 1995 has changed the way we think about the Universe: our solar system is not unique. Twenty years later, we know that planetary systems are ubiquitous, orbit stars spanning a wide range in mass, and form in an astonishing variety of architectures. Yet, one fascinating aspect of planetary systems has received relatively little attention so far: their ultimate fate.Most planet hosts will eventually evolve into white dwarfs, Earth-sized stellar embers, and the outer parts of their planetary systems (in the solar system, Mars and beyond) can survive largely intact for billions of years. While scattered and tidally disrupted planetesimals are directly detected at a small number of white dwarfs in the form infrared excess, the most powerful probe for detecting evolved planetary systems is metal pollution of the otherwise pristine H/He atmospheres.I will present the results of a multi-cycle HST survey that has obtained COS observations of 136 white dwarfs. These ultraviolet spectra are exquisitely sensitive to the presence of metals contaminating the white atmosphere. Our sophisticated model atmosphere analysis demonstrates that at least 27% of all targets are currently accreting planetary debris, and an additional 29% have very likely done so in the past. These numbers suggest that planet formation around A-stars (the dominant progenitors of today's white dwarf population) is similarly efficient as around FGK stars.In addition to post-main sequence planetary system demographics, spectroscopy of the debris-polluted white dwarf atmospheres provides a direct window into the bulk composition of exo-planetesimals, analogous to the way we use of meteorites to determine solar-system abundances. Our ultraviolet spectroscopy is particularly sensitive to the detection of Si, a dominant rock-forming species, and we identify up to ten additional volatile and refractory elements in the most strongly

  3. Laser fusion system design study. Final report

    International Nuclear Information System (INIS)

    1975-01-01

    The following studies were completed: (1) The synthesis of a pointing/control system compatible with existing and advanced laser opto-mechanical configurations. (2) Attainment of the required pointing angle, longitudinal focus, and differential pathlength accuracies. (3) Maximum modularization of the sensor and gimbal assemblies to provide the required accuracies at minimum cost. Detailed information is given on each. (MOW)

  4. Noncirrhotic portal hypertension.

    Science.gov (United States)

    Da, Ben L; Koh, Christopher; Heller, Theo

    2018-05-01

    Noncirrhotic portal hypertension represents a heterogeneous group of liver disorders that is characterized by portal hypertension in the absence of cirrhosis. The purpose of this review is to serve as a guide on how to approach a patient with noncirrhotic portal hypertension with a focus on recent developments. Recent studies pertaining to noncirrhotic portal hypertension have investigated aetiological causes, mechanisms of disease, noninvasive diagnostic modalities, clinical characteristics in the paediatric population and novel treatment targets. Noncirrhotic portal hypertension is an underappreciated clinical entity that can be difficult to diagnosis without a healthy suspicion. Diagnosis then relies on a comprehensive understanding of the causes and clinical manifestations of this disease, as well as a careful interpretation of the liver biopsy. Noninvasive approaches to diagnosis may play a significant role moving forward in this disease. Treatment in NCPH remains largely targeted at the individual sequalae of portal hypertension.

  5. Hepatic angiography: Portal hypertension

    International Nuclear Information System (INIS)

    Oliver, T.W. Jr.; Sones, P.J. Jr.

    1985-01-01

    Portal hypertension is usually a manifestation of underlying hepatic parenchymal disease, although it may be secondary to portal or hepatic venous thrombosis and rarely to hyperdynamic portal states. Portal hypertension may present as encephalopathy, ascites, jaundice, hepatic failure, or catastrophic upper gastrointestinal hemorrhage. Radiologic investigation should include indirect or direct measurements of portal pressure, assessment of portal venous perfusion, visualization of collaterals, and demonstration of arterial and venous anatomy for potential shunt procedure. Following survival of initial variceal bleeding, the most effective procedure to prevent recurrent hemorrhage is a shunt to decompress the varices. The decision whether to intervene medically or surgically during the acute hemorrhagic episode as well as the type of shunt used to prevent future hemorrhage is the subject of continuing controversy

  6. Pediatric portal hypertension

    Science.gov (United States)

    Vogel, Clarissa Barbon

    2017-01-01

    Abstract: Pediatric portal hypertension management is a team approach between the patient, the patient's family, the primary caregiver, and specialty providers. Evidence-based practice guidelines have not been established in pediatrics. This article serves as a review for the primary care NP in the management of pediatric portal hypertension, discussing the etiology, pathophysiology, and clinical presentation of pediatric portal hypertension, diagnostic tests, and treatment and management options. PMID:28406835

  7. Usability of Discovery Portals

    OpenAIRE

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals are not spatial data experts but professionals with limited spatial knowledge, and a focus outside the spatial domain. An exploratory usability experiment was carried out in which three discovery p...

  8. The Effectiveness of Web-Based Asthma Self-Management System, My Asthma Portal (MAP): A Pilot Randomized Controlled Trial.

    Science.gov (United States)

    Ahmed, Sara; Ernst, Pierre; Bartlett, Susan J; Valois, Marie-France; Zaihra, Tasneem; Paré, Guy; Grad, Roland; Eilayyan, Owis; Perreault, Robert; Tamblyn, Robyn

    2016-12-01

    Whether Web-based technologies can improve disease self-management is uncertain. My Asthma Portal (MAP) is a Web-based self-management support system that couples evidence-based behavioral change components (self-monitoring of symptoms, physical activity, and medication adherence) with real-time monitoring, feedback, and support from a nurse case manager. The aim of this study was to compare the impact of access to a Web-based asthma self-management patient portal linked to a case-management system (MAP) over 6 months compared with usual care on asthma control and quality of life. A multicenter, parallel, 2-arm, pilot, randomized controlled trial was conducted with 100 adults with confirmed diagnosis of asthma from 2 specialty clinics. Asthma control was measured using an algorithm based on overuse of fast-acting bronchodilators and emergency department visits, and asthma-related quality of life was assessed using the Mini-Asthma Quality of Life Questionnaire (MAQLQ). Secondary mediating outcomes included asthma symptoms, depressive symptoms, self-efficacy, and beliefs about medication. Process evaluations were also included. A total of 49 individuals were randomized to MAP and 51 to usual care. Compared with usual care, participants in the intervention group reported significantly higher asthma quality of life (mean change 0.61, 95% CI 0.03 to 1.19), and the change in asthma quality of life for the intervention group between baseline and 3 months (mean change 0.66, 95% CI 0.35 to 0.98) was not seen in the control group. No significant differences in asthma quality of life were found between the intervention and control groups at 6 (mean change 0.46, 95% CI -0.12 to 1.05) and 9 months (mean change 0.39, 95% CI -0.2 to 0.98). For poor control status, there was no significant effect of group, time, or group by time. For all self-reported measures, the intervention group had a significantly higher proportion of individuals, demonstrating a minimal clinically

  9. Power system EMP protection. Final report

    International Nuclear Information System (INIS)

    Marable, J.H.; Barnes, P.R.; Nelson, D.B.

    1975-05-01

    Voltage transients induced in electric power lines and control circuits by the electromagnetic pulse (EMP) from high-altitude nuclear detonations may cause widespread power failure and damage in electric power systems. This report contains a parametric study of EMP power line surges and discusses protective measures to minimize their effects. Since EMP surges have considerably greater rates of rise than lightning surges, recommended standards and test procedures are given to assure that surge arresters protect equipment from damage by EMP. Expected disturbances and damage to power systems are reviewed, and actions are presented which distribution companies can take to counter them. These include backup communications methods, stockpiling of vulnerable parts, repair procedures, and dispatcher actions to prevent blackout from EMP-caused instabilities. A long-range program is presented for improving distributors' protection against EMP. This involves employee training, hardware protection for power and control circuits, and improvement of plans for emergency action. (U.S.)

  10. PLOCAN glider portal: a gateway for useful data management and visualization system

    Science.gov (United States)

    Morales, Tania; Lorenzo, Alvaro; Viera, Josue; Barrera, Carlos; José Rueda, María

    2014-05-01

    Nowadays monitoring ocean behavior and its characteristics involves a wide range of sources able to gather and provide a vast amount of data in spatio-temporal scales. Multiplatform infrastructures, like PLOCAN, hold a variety of autonomous Lagrangian and Eulerian devices addressed to collect information then transferred to land in near-real time. Managing all this data collection in an efficient way is a major issue. Advances in ocean observation technologies, where underwater autonomous gliders play a key role, has brought as a consequence an improvement of spatio-temporal resolution which offers a deeper understanding of the ocean but requires a bigger effort in the data management process. There are general requirements in terms of data management in that kind of environments, such as processing raw data at different levels to obtain valuable information, storing data coherently and providing accurate products to final users according to their specific needs. Managing large amount of data can be certainly tedious and complex without having right tools and operational procedures; hence automating these tasks through software applications saves time and reduces errors. Moreover, data distribution is highly relevant since scientist tent to assimilate different sources for comparison and validation. The use of web applications has boosted the necessary scientific dissemination. Within this argument, PLOCAN has implemented a set of independent but compatible applications to process, store and disseminate information gathered through different oceanographic platforms. These applications have been implemented using open standards, such as HTML and CSS, and open source software, like python as programming language and Django as framework web. More specifically, a glider application has been developed within the framework of FP7-GROOM project. Regarding data management, this project focuses on collecting and making available consistent and quality controlled datasets as

  11. Integrated radwaste treatment system. Final report

    International Nuclear Information System (INIS)

    Baker, M.N.; Houston, H.M.

    1997-10-01

    In May 1988, the West Valley Demonstration Project (WVDP) began pretreating liquid high-level radioactive waste (HLW). This HLW was produced during spent nuclear fuel reprocessing operations that took place at the Western New York Nuclear Service Center from 1966 to 1972. Original reprocessing operations used plutonium/uranium extraction (PUREX) and thorium extraction (THOREX) processes to recover usable isotopes from spent nuclear fuel. The PUREX process produced a nitric acid-based waste stream, which was neutralized by adding sodium hydroxide to it. About two million liters of alkaline liquid HLW produced from PUREX neutralization were stored in an underground carbon steel tank identified as Tank 8D-2. The THOREX process, which was used to reprocess one core of mixed uranium-thorium fuel, resulted in about 31,000 liters of acidic waste. This acidic HLW was stored in an underground stainless steel tank identified as Tank 8D-4. Pretreatment of the HLW was carried out using the Integrated Radwaste Treatment System (IRTS), from May 1988 until May 1995. This system was designed to decontaminate the liquid HLW, remove salts from it, and encapsulate the resulting waste into a cement waste form that achieved US Nuclear Regulatory Commission (NRC) criteria for low-level waste (LLW) storage and disposal. A thorough discussion of IRTS operations, including all systems, subsystems, and components, is presented in US Department of Energy (DOE) Topical Report (DOE/NE/44139-68), Integrated Radwaste Treatment System Lessons Learned from 2 1/2 Years of Operation. This document also presents a detailed discussion of lessons learned during the first 2 1/2 years of IRTS operation. This report provides a general discussion of all phases of IRTS operation, and presents additional lessons learned during seven years of IRTS operation

  12. Filling the Gaps in a Fragmented Health Care System: Development of the Health and Welfare Information Portal (ZWIP).

    Science.gov (United States)

    Robben, Sarah Hm; Huisjes, Mirjam; van Achterberg, Theo; Zuidema, Sytse U; Olde Rikkert, Marcel Gm; Schers, Henk J; Heinen, Maud M; Melis, René Jf

    2012-09-19

    Current health care systems are not optimally designed to meet the needs of our aging populations. First, the fragmentation of care often results in discontinuity of care that can undermine the quality of care provided. Second, patient involvement in care decisions is not sufficiently facilitated. To describe the development and the content of a program aimed at: (1) facilitating self-management and shared decision making by frail older people and informal caregivers, and (2) reducing fragmentation of care by improving collaboration among professionals involved in the care of frail older people through a combined multidisciplinary electronic health record (EHR) and personal health record (PHR). We used intervention mapping to systematically develop our program in six consecutive steps. Throughout this development, the target populations (ie, professionals, frail older people, and informal caregivers) were involved extensively through their participation in semi-structured interviews and working groups. We developed the Health and Welfare Information Portal (ZWIP), a personal, Internet-based conference table for multidisciplinary communication and information exchange for frail older people, their informal caregivers, and professionals. Further, we selected and developed methods for implementation of the program, which included an interdisciplinary educational course for professionals involved in the care of frail older people, and planned the evaluation of the program. This paper describes the successful development and the content of the ZWIP as well as the strategies developed for its implementation. Throughout the development, representatives of future users were involved extensively. Future studies will establish the effects of the ZWIP on self-management and shared decision making by frail older people as well as on collaboration among the professionals involved.

  13. BSD Portals for LINUX 2.0

    Science.gov (United States)

    McNab, A. David; woo, Alex (Technical Monitor)

    1999-01-01

    Portals, an experimental feature of 4.4BSD, extend the file system name space by exporting certain open () requests to a user-space daemon. A portal daemon is mounted into the file name space as if it were a standard file system. When the kernel resolves a pathname and encounters a portal mount point, the remainder of the path is passed to the portal daemon. Depending on the portal "pathname" and the daemon's configuration, some type of open (2) is performed. The resulting file descriptor is passed back to the kernel which eventually returns it to the user, to whom it appears that a "normal" open has occurred. A proxy portalfs file system is responsible for kernel interaction with the daemon. The overall effect is that the portal daemon performs an open (2) on behalf of the kernel, possibly hiding substantial complexity from the calling process. One particularly useful application is implementing a connection service that allows simple scripts to open network sockets. This paper describes the implementation of portals for LINUX 2.0.

  14. Customisable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion. Web portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as Twitter and other social networks. In this series of slides, we describe the software architecture of this scientific web portal and our experiences in utilizing web 2.0 technologies. A

  15. Final Report of Strongly Interacting Fermion Systems

    International Nuclear Information System (INIS)

    Wilkins, J. W.

    2001-01-01

    There has been significant progress in three broad areas: (A) Optical properties, (B) Large-scale computations, and (C) Many-body systems. In this summary the emphasis is primarily on those papers that point to the research plans. At the same time, some important analytic work is not neglected, some of it even appearing in the description of large-scale Computations. Indeed one of the aims of such computations is to give new insights which lead to development of models capable of simple analytic or nearly analytic analysis

  16. Quantitative vs. subjective portal verification using digital portal images.

    Science.gov (United States)

    Bissett, R; Leszczynski, K; Loose, S; Boyko, S; Dunscombe, P

    1996-01-15

    Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamfer matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 degrees. For all four oncologists, the portals classified

  17. Dual Manifold System for Arraying Biomolecules; FINAL

    International Nuclear Information System (INIS)

    Doktycz, M.J.

    2001-01-01

    The objective of this CRADA is to establish a new approach to fluid transfer and array construction. This new approach will involve a high-speed, multiplexed fluid distribution valve and ink jet valves. It will enable the parallel handling of multiple reagents for a system that will have multiple applications in addition to the high-speed construction of microarrays. The primary tasks involve proof of principle experiments aimed at establishing key components of the technology and evaluating various optional configurations. The basic platform for evaluating the technology will be set-up by the Contractor at Oak Ridge National Laboratory (ORNL) and will employ custom valving prepared by Rheodyne. The test platform will consist of a motion controller, 3-axes of motion, software, and pneumatic control; and will be used to evaluate the hybrid valve

  18. Autonomic dysfunction in cirrhosis and portal hypertension

    DEFF Research Database (Denmark)

    Dümcke, Christine Winkler; Møller, Søren

    2008-01-01

    Liver cirrhosis and portal hypertension are frequently associated with signs of circulatory dysfunction and peripheral polyneuropathy, which includes defects of the autonomic nervous system. Autonomic dysfunction, which is seen in both alcoholic and non-alcoholic liver cirrhosis and increases...

  19. A Dynamic Information Framework (DIF): A Portal for the Changing Biogeochemistry of Aquatic Systems

    Science.gov (United States)

    Richey, J. E.; Fernandes, E. C. M.

    2014-12-01

    The ability of societies to adapt to climate and landuse change in aquatic systems is functionally and practically expressed by how regional stakeholders are able to address complex management issues. These targets represent a very complex set of intersecting issues of scale, cross-sector science and technology, education, politics, and economics. Implications transcend individual projects and ministries. An immediate challenge is to incorporate the realities of changing environmental conditions in these sectors into the policies and projects of the Ministries nominally responsible. Ideally this would be done on the basis of the absolute best understanding of the issues involved, and done in a way that optimizes a multi-stakeholder return. Central to a response is "actionable information-" the synthesis and "bringing to life" of the key information that integrates the end-to-end knowledge required to provide the high-level decision support to make the most informed decisions. But, in practice, the information necessary and even perspectives are virtually absent, in much of especially the developing world. To meet this challenge, we have been developing a Dynamic Information Framework (DIF), primarily through collaborations with the World Bank in Asia, Africa, and Brazil. The DIF is, essentially a decision support structure, built around "earth system" models. The environment is built on progressive information layers that are fed through hydrological and geospatial landscape models to produce outputs that address specific science questions related to water resources management of the region. Information layers from diverse sources are assembled, according to the principles of how the landscape is organized, and computer models are used to bring the information "to life." A fundamental aspect to a DIF is not only the convergence of multi-sector information, but how that information can be conveyed, in the most compelling, and visual, manner. Deployment of the

  20. Buried waste containment system materials. Final Report

    International Nuclear Information System (INIS)

    Weidner, J.R.; Shaw, P.G.

    1997-10-01

    This report describes the results of a test program to validate the application of a latex-modified cement formulation for use with the Buried Waste Containment System (BWCS) process during a proof of principle (POP) demonstration. The test program included three objectives. One objective was to validate the barrier material mix formulation to be used with the BWCS equipment. A basic mix formula for initial trials was supplied by the cement and latex vendors. The suitability of the material for BWCS application was verified by laboratory testing at the Idaho National Engineering and Environmental Laboratory (INEEL). A second objective was to determine if the POP BWCS material emplacement process adversely affected the barrier material properties. This objective was met by measuring and comparing properties of material prepared in the INEEL Materials Testing Laboratory (MTL) with identical properties of material produced by the BWCS field tests. These measurements included hydraulic conductivity to determine if the material met the US Environmental Protection Agency (EPA) requirements for barriers used for hazardous waste sites, petrographic analysis to allow an assessment of barrier material separation and segregation during emplacement, and a set of mechanical property tests typical of concrete characterization. The third objective was to measure the hydraulic properties of barrier material containing a stop-start joint to determine if such a feature would meet the EPA requirements for hazardous waste site barriers

  1. Mirror confinement systems: Final technical report

    International Nuclear Information System (INIS)

    1988-08-01

    This report contains: (1) A discussion of azimuthal asymmetrics and fluctuations in RFC-XX-M. Both lead to enhanced radial transport in RFC-XX-M, and presumably most other tandem mirror machines as well; A report on four operating modes of RFC-XX-M which were developed and studied as part of the collaboration. These operating modes were the simple tandem mode, the negative (floating) potential mode, the hot electron mode, and the ECH (electron cyclotron heating) mode; A pulsed rf heated discharge cleaning system which was developed for RFC-XX-M. This method of cleaning proved much more effective than normal glow discharge cleaning, and variations of it are currently in use on the GAMMA-10 tandem mirror and the JIPP TII-U tokamak at the Institute for Plasma Physics at Nagoya; Short descriptions of the diagnostics development and improvement done in conjunction with the work on RFC-XX-M; and a compilation of the work performed at the University of Tsukuba on GAMMA-10. Most of the effort on GAMMA-10 involved diagnostics development and improvement. 16 refs., 42 figs., 1 tab

  2. Condenser inleakage monitoring system development. Final report

    International Nuclear Information System (INIS)

    Kassen, W.R.; Putkey, T.A.; Sawochka, S.G.; Pearl, W.L.; Clouse, M.E.

    1982-09-01

    An instrument/hardware package for air and condenser cooling water inleakage location employing the helium and freon techniques was designed and fabricated. The package consists of design details for tracer gas distribution hardware, injection plenums, and a sample preconditioner and instrument module. Design of the package was based on an evaluation of helium and freon leak detectors and a survey of utility user's experience with the helium and freon techniques. The applicability of the instrument/hardware package to air and cooling water inleakage location was demonstrated at Pacific Gas and Electric Company's Moss Landing Station. The use of calibrated leaks indicated that cooling water leaks down to 1.5 x 10 -4 gpm (0.56 ml/min) and air leaks down to 0.05 cfm were readily detectable with the helium technique, whereas a 4 x 10 -4 gpm (1.5 ml/min) liquid leak was the readily detectable minimum via the freon technique. The field demonstration and in-house detector testing showed the helium technique to be preferable to the freon technique for inleakage location at PWRs, BWRs, and fossil-fueled systems

  3. Transactive Campus Energy Systems: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Haack, Jereme N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hao, He [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kim, Woohyun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hostick, Donna J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Akyol, Bora A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Allwardt, Craig H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Carpenter, Brandon J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Sen [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Guopeng [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lutes, Robert G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Makhmalbaf, Atefe [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ngo, Hung [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Somasundaram, Sriram [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Underhill, Ronald M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-09-26

    Transactive energy refers to the combination of economic and control techniques to improve grid reliability and efficiency. The fundamental purpose of transactive energy management is to seamlessly coordinate the operation of large numbers of new intelligent assets—such as distributed solar, energy storage and responsive building loads—to provide the flexibility needed to operate the power grid reliably and at minimum cost, particularly one filled with intermittent renewable generation such as the Pacific Northwest. It addresses the key challenge of providing smooth, stable, and predictable “control” of these assets, despite the fact that most are neither owned nor directly controlled by the power grid. The Clean Energy and Transactive Campus (CETC) work described in this report was done as part of a Cooperative Research and Development Agreement (CRADA) between the U.S. Department of Energy’s Pacific Northwest National Laboratory (PNNL) and the Washington State Department of Commerce (Commerce) through the Clean Energy Fund (CEF). The project team consisted of PNNL, the University of Washington (UW) and Washington State University (WSU), to connect the PNNL, UW, and WSU campuses to form a multi-campus testbed for transaction-based energy management—transactive—solutions. Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), the purpose of the project was to construct the testbed as both a regional flexibility resource and as a platform for research and development (R&D) on buildings/grid integration and information-based energy efficiency. This report provides a summary of the various tasks performed under the CRADA.

  4. DECONTAMINATION SYSTEMS AND INFORMATION RESEARCH PROGRAM; FINAL

    International Nuclear Information System (INIS)

    Echol E. Cook, Ph.D., PE.

    1998-01-01

    Tek Centrifugal Membrane System was a unique separation process introduced through the Agreement that is now being used at the Los Alamos National Laboratory. Based on the cost to the USDOE for both technologies and considering their usefulness in cleaning up contaminated sites, no other technologies developed through USDOE provide or have the propensity to provide as great a return on investment and impact on environmental remediation. These technologies alone make the$10.3 million USDOE investment in the WVU Cooperative Agreement a tremendous investment

  5. The completed design of the SLC Final Focus System

    International Nuclear Information System (INIS)

    Murray, J.J.; Brown, K.L.; Fieguth, T.

    1987-02-01

    The design of the SLC Final Focus System has evolved from its initial conceptual design into its final form. This final design is described including a review of the critical decisions influencing the adoption of particular features. The creation of a feasible design has required that these decisions be tempered by practical considerations such as site constraints, correction of optical errors caused by imperfections, and accommodations requested by engineers and particle detector physicists. As this is the first such system to be built, it is hoped that the experience gained will be useful for the design of future systems

  6. Cultura tecnológica e redes sociotécnicas: um estudo sobre o portal da rede municipal de ensino de São Paulo Technological culture and sociotechnical networks: a study of the São Paulo municipal school system web portal

    Directory of Open Access Journals (Sweden)

    Zulmira Medeiros

    2008-04-01

    Full Text Available A realização deste estudo deu-se a partir da hipótese de que as instituições educacionais ou redes de ensino podem utilizar a internet para estabelecer uma nova forma de contato administrativo e pedagógico dentro das suas comunidades escolares. O referencial teórico parte de elementos como mudanças sociais, culturais e tecnológicas para, em seguida, situar em tal contexto o educador e sua apropriação da cultura tecnológica. Ao final, aborda a constituição de redes sociotécnicas no meio educacional, tendo a internet como elemento facilitador. Para isso, trata também de temas como as redes sociais e os portais educacionais. Em campo, buscou-se investigar o processo de constituição de uma rede sociotécnica em uma rede municipal de ensino. Por meio de observações, levantamentos, questionários e entrevistas, realizou-se um estudo de caso, no qual foi possível acompanhar a criação, implantação e utilização de um portal na internet, caracterizado como um novo espaço de comunicação, de interação e de troca de informações entre a comunidade escolar. A investigação concentrou-se na figura do educador e sua percepção acerca desse espaço. Acreditando que a relação entre o homem e a tecnologia envolve um processo de apropriação da cultura tecnológica, que influencia diretamente a sua atuação na sociedade em rede, pôde-se concluir que portais educacionais podem ser utilizados por instituições de ensino, de forma produtiva e colaborativa, entre todos os atores da comunidade educacional, desde que em tal processo se leve em consideração, dentre outros aspectos, a cultura tecnológica dessa comunidade.The point of departure for this study is the hypothesis that educational institutions and school systems can use the Internet to establish a new form of administrative and pedagogical contact within their school communities. The theoretical framework involves elements such as social, cultural, and technological

  7. Dose patient verification during treatment using an amorphous silicon electronic portal imaging device in radiotherapy

    International Nuclear Information System (INIS)

    Berger, Lucie

    2006-01-01

    Today, amorphous silicon electronic portal imaging devices (aSi EPID) are currently used to check the accuracy of patient positioning. However, they are not use for dose reconstruction yet and more investigations are required to allow the use of an aSi EPID for routine dosimetric verification. The aim of this work is first to study the dosimetric characteristics of the EPID available at the Institut Curie and then, to check patient dose during treatment using these EPID. First, performance optimization of the Varian aS500 EPID system is studied. Then, a quality assurance system is set up in order to certify the image quality on a daily basis. An additional study on the dosimetric performance of the aS500 EPID is monitored to assess operational stability for dosimetry applications. Electronic portal imaging device is also a useful tool to improve IMRT quality control. The validation and the quality assurance of a portal dose image prediction system for IMRT pre-treatment quality control are performed. All dynamic IMRT fields are verified in clinical routine with the new method based on portal dosimetry. Finally, a new formalism for in vivo dosimetry using transit dose measured with EPID is developed and validated. The absolute dose measurement issue using aSi EPID is described and the midplane dose determination using in vivo dose measurements in combination with portal imaging is used with 3D-conformal-radiation therapy. (author) [fr

  8. Portal cholangiopathy: case report

    Directory of Open Access Journals (Sweden)

    Maria Cecilia Almeida Maia

    2014-01-01

    Full Text Available The present report describes the case of a child that after blunt abdominal trauma presented with portal thrombosis followed by progressive splenomegaly and jaundice. Ultrasonography and percutaneous cholangiography revealed biliary dilatation secondary to choledochal stenosis caused by dilated peribiliary veins, characterizing a case of portal biliopathy. The present case report is aimed at presenting an uncommon cause of this condition.

  9. Portal hypertension: a review of portosystemic collateral pathways and endovascular interventions

    International Nuclear Information System (INIS)

    Pillai, A.K.; Andring, B.; Patel, A.; Trimmer, C.; Kalva, S.P.

    2015-01-01

    The portal vein is formed at the confluence of the splenic and superior mesenteric vein behind the head of the pancreas. Normal blood pressure within the portal system varies between 5 and 10 mmHg. Portal hypertension is defined when the gradient between the portal and systemic venous blood pressure exceeds 5 mmHg. The most common cause of portal hypertension is cirrhosis. In cirrhosis, portal hypertension develops due to extensive fibrosis within the liver parenchyma causing increased vascular resistance. In addition, the inability of the liver to metabolise certain vasodilators leads to hyperdynamic splanchnic circulation resulting in increased portal blood flow. Decompression of the portal pressure is achieved by formation of portosystemic collaterals. In this review, we will discuss the pathophysiology, anatomy, and imaging findings of spontaneous portosystemic collaterals and clinical manifestations of portal hypertension with emphasis on the role of interventional radiology in the management of complications related to portal hypertension

  10. Patient portals and broadband internet inequality.

    Science.gov (United States)

    Perzynski, Adam T; Roach, Mary Joan; Shick, Sarah; Callahan, Bill; Gunzler, Douglas; Cebul, Randall; Kaelber, David C; Huml, Anne; Thornton, John Daryl; Einstadter, Douglas

    2017-09-01

    Patient portals have shown potential for increasing health care quality and efficiency. Internet access and other factors influencing patient portal use could worsen health disparities. Observational study of adults with 1 or more visits to the outpatient clinics of an urban public health care system from 2012 to 2015. We used mixed effects logistic regression to evaluate the association between broadband internet access and (1) patient portal initiation (whether a patient logged in at least 1 time) and (2) messaging, controlling for demographic and neighborhood characteristics. There were 243 248 adults with 1 or more visits during 2012-2015 and 70 835 (29.1%) initiated portal use. Portal initiation was 34.1% for whites, 23.4% for blacks, and 23.8% for Hispanics, and was lower for Medicaid (26.5%), Medicare (23.4%), and uninsured patients (17.4%) than commercially insured patients (39.3%). In multivariate analysis, both initiation of portal use (odds ratio [OR] = 1.24 per quintile, 95% confidence interval [CI], 1.23-1.24, P  internet access. The majority of adults with outpatient visits to a large urban health care system did not use the patient portal, and initiation of use was lower for racial and ethnic minorities, persons of lower socioeconomic status, and those without neighborhood broadband internet access. These results suggest the emergence of a digital divide in patient portal use. Given the scale of investment in patient portals and other internet-dependent health information technologies, efforts are urgently needed to address this growing inequality. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  11. The XCAT Science Portal

    Directory of Open Access Journals (Sweden)

    Sriram Krishnan

    2002-01-01

    Full Text Available This paper describes the design and prototype implementation of the XCAT Grid Science Portal. The portal lets grid application programmers script complex distributed computations and package these applications with simple interfaces for others to use. Each application is packaged as a notebook which consists of web pages and editable parameterized scripts. The portal is a workstation-based specialized personal web server, capable of executing the application scripts and launching remote grid applications for the user. The portal server can receive event streams published by the application and grid resource information published by Network Weather Service (NWS [35] or Autopilot [16] sensors. Notebooks can be published and stored in web based archives for others to retrieve and modify. The XCAT Grid Science Portal has been tested with various applications, including the distributed simulation of chemical processes in semiconductor manufacturing and collaboratory support for X-ray crystallographers.

  12. Mouse and Rat Models of Induction of Hepatic Fibrosis and Assessment of Portal Hypertension.

    Science.gov (United States)

    Klein, Sabine; Schierwagen, Robert; Uschner, Frank Erhard; Trebicka, Jonel

    2017-01-01

    Portal hypertension either develops due to progressive liver fibrosis or is the consequence of vascular liver diseases such as portal vein thrombosis or non-cirrhotic portal hypertension. This chapter focuses on different rodent models of liver fibrosis with portal hypertension and also in few non-cirrhotic portal hypertension models. Importantly, after the development of portal hypertension, the proper assessment of drug effects in the portal and systemic circulation should be discussed. The last part of the chapter is dedicated in these techniques to assess the in vivo hemodynamics and the ex vivo techniques of the isolated liver perfusion and vascular contractility.

  13. Diabetes diminishes the portal-systemic collateral vascular response to vasopressin via vasopressin receptor and Gα proteins regulations in cirrhotic rats.

    Directory of Open Access Journals (Sweden)

    Jing-Yi Lee

    Full Text Available Liver cirrhosis may lead to portal-systemic collateral formation and bleeding. The hemostatic effect is influenced by the response of collateral vessels to vasoconstrictors. Diabetes and glucose also influence vasoresponsiveness, but their net effect on collaterals remains unexplored. This study investigated the impact of diabetes or glucose application on portal-systemic collateral vasoresponsiveness to arginine vasopressin (AVP in cirrhosis. Spraque-Dawley rats with bile duct ligation (BDL-induced cirrhosis received vehicle (citrate buffer or streptozotocin (diabetic, BDL/STZ. The in situ collateral perfusion was done after hemodynamic measurements: Both were perfused with Krebs solution, D-glucose, or D-glucose and NaF, with additional OPC-31260 for the BDL/STZ group. Splenorenal shunt vasopressin receptors and Gα proteins mRNA expressions were evaluated. The survival rate of cirrhotic rats was decreased by STZ injection. The collateral perfusion pressure changes to AVP were lower in STZ-injected groups, which were reversed by OPC-31260 (a V2R antagonist and overcome by NaF (a G protein activator. The splenorenal shunt V2R mRNA expression was increased while Gα proteins mRNA expressions were decreased in BDL/STZ rats compared to BDL rats. The Gαq and Gα11 mRNA expressions also correlated with the maximal perfusion pressure changes to AVP. Diabetes diminished the portal-systemic collateral vascular response to AVP in rats with BDL-induced cirrhosis, probably via V2 receptor up-regulation and Gα proteins down-regulation.

  14. Portal Vein Stenting for Portal Biliopathy with Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dongho, E-mail: mesentery@naver.com; Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center (Korea, Republic of); Lim, Seong Joo [Konyang University, Department of Radiology, College of Medicine, Konyang University Hospital (Korea, Republic of); Hwang, Jin Ho [Hallym University Sacred Heart Hospital, Department of Radiology (Korea, Republic of); Sinn, Dong Hyun [Sungkyunkwan University School of Medicine, Department of Medicine, Samsung Medical Center (Korea, Republic of)

    2016-04-15

    Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

  15. General method for final focus system design for circular colliders

    Directory of Open Access Journals (Sweden)

    Riccardo de Maria

    2008-03-01

    Full Text Available Colliders use final focus systems to reduce the transverse beam sizes at the interaction point in order to increase collision event rates. The maximum focal strength (gradient of the quadrupoles, and the maximum beam size in them, together limit the beam size reduction that is possible. The goal of a final focus system design is to find the best compromise between quadrupole aperture and quadrupole gradient, for the magnet technology that is used. This paper develops a design method that identifies the intrinsic limitations of a final focus system, validates the results of the method against realistic designs, and reports its application to the upgrade of the Large Hadron Collider final focus.

  16. Portal vein thrombosis.

    Science.gov (United States)

    Chawla, Yogesh K; Bodh, Vijay

    2015-03-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion.

  17. Effect of portal access system and surgery type on surgery times during laparoscopic ovariectomy and salpingectomy in captive African lions and cheetahs.

    Science.gov (United States)

    Hartman, Marthinus Jacobus; Monnet, Eric; Kirberger, Robert Murco; Schoeman, Johan Petrus

    2016-03-02

    A prospective randomized study was used to compare surgery times for laparoscopic ovariectomy and salpingectomy in female African lion (Panthera leo) (n = 14) and cheetah (Acinonyx jubatus) (n = 20) and to compare the use of a multiple portal access system (MPAS) and single portal access system (SPAS) between groups. Two different portal techniques were used, namely MPAS (three separate ports) in lions and SPAS (SILS™ port) in cheetahs, using standard straight laparoscopic instruments. Portal access system and first ovary was not randomized. Five different surgery times were compared for the two different procedures as well as evaluating the use and application of MPAS and SPAS. Carbon dioxide volumes for lions were recorded. In adult lionesses operative time (OPT) (P = 0.016) and total surgical time (TST) (P = 0.032) were significantly shorter for salpingectomy compared to ovariectomy. Similarly in cheetahs OPT (P = 0.001) and TST (P = 0.005) were also shorter for salpingectomy compared to ovariectomy. In contrast, in lion cubs no difference was found in surgery times for ovariectomy and salpingectomy. Total unilateral procedure time was shorter than the respective bilateral time for both procedures (P = 0.019 and P = 0.001) respectively and unilateral salpingectomy was also faster than unilateral ovariectomy (P = 0.035) in cheetahs. Port placement time, suturing time and TST were significantly shorter for SPAS compared to MPAS (P = 0.008). There was, however, no difference in OPT between SPAS and MPAS. Instrument cluttering with SPAS was found to be negligible. There was no difference in mean volume CO2 required to complete ovariectomy in lions but the correlation between bodyweight and total volume of CO2 in lions was significant (rs = 0.867; P = 0.002). Laparoscopic salpingectomy was faster than ovariectomy in both adult lions and cheetahs. Using SPAS, both unilateral procedures were faster than bilateral procedures in cheetahs

  18. The ADRICOSM STAR GeoPortal

    Science.gov (United States)

    Giorgetti, Alessandra; Cesarini, Claudia; Gambetta, Marco; Reseghetti, Franco; Vinci, Matteo

    2010-05-01

    are checked after first use for up-grading and additional quality control to ensure that all relevant data are preserved for final archival. In summary the ADRICOSM Geoportal has: - the objective to support data exchange in Adricosm Star and the implementation of tools to facilitate the access to data and information through thematic portals, converting individual data provider systems into a federation. - provide the necessary information to users on content of data that can be accessed in the federated systems. The portal is organised in three modules and a catalog. The module 1 has been realized by giving information on the project and objectives, data policy, reasons to provide products and services, link to the themes. Skilled people can jump to the data/products/services provider by clicking on the geographical map. Module 2 is providing more specific information on centers providing data/products/services. Module 3 is providing a direct access to partners product. It contains a short description of the products and a link. Module 4 contain the catalog for each partner product and is based on What, Where, When and How.

  19. A chess web portal

    OpenAIRE

    Volf, Žiga

    2011-01-01

    The aim of the thesis was to develop a web portal for chess players, which is intended to be a place for quality chess joining over the Internet and chess education. This need is caused by existing social networks and websites for playing chess, which offer you a very small amount of quality chess joining and education. As a result of the work the chess portal was created. We have presented the development of the chess portal in the thesis, which has all the features the chess players are i...

  20. Scintiphotosplenoportography in patients with portal hypertension

    International Nuclear Information System (INIS)

    Aijaz, A.

    1990-01-01

    Scintiphotosplenoportograpy (SSP) was performed in five normals and 25 patients with portal hypertension using Tc-99m tin colloid. 12 patients were cirrhotic and 13 had idiopathic portal hypertension (IPH). Analogue and fast frame dynamic studies were performed and subsequently processed. Intra hepatic shunt index in cirrhotics was significantly different from the IPH group. Extra hepatic shunt index, however, was not significantly different in the two groups but was related more to the severity of the disease process. Spleno hepatic and spleno cardiac transit times were significantly lower cirrhotics as compared to the IPH group. We conclude that SSP is a technically simple, rapid and a much less invasive method of visualizing the portal circulatory system and assessing the portal haemo dynamics. it also provides clinically important measure of shunted blood nd allows for the quantification of circulatory time from spleen to liver and heart. (author)

  1. FOCUS: a fire management planning system -- final report

    Science.gov (United States)

    Frederick W. Bratten; James B. Davis; George T. Flatman; Jerold W. Keith; Stanley R. Rapp; Theodore G. Storey

    1981-01-01

    FOCUS (Fire Operational Characteristics Using Simulation) is a computer simulation model for evaluating alternative fire management plans. This final report provides a broad overview of the FOCUS system, describes two major modules-fire suppression and cost, explains the role in the system of gaming large fires, and outlines the support programs and ways of...

  2. Model validation studies of solar systems, Phase III. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Lantz, L.J.; Winn, C.B.

    1978-12-01

    Results obtained from a validation study of the TRNSYS, SIMSHAC, and SOLCOST solar system simulation and design are presented. Also included are comparisons between the FCHART and SOLCOST solar system design programs and some changes that were made to the SOLCOST program. Finally, results obtained from the analysis of several solar radiation models are presented. Separate abstracts were prepared for ten papers.

  3. Portal hypertension and liver cirrhosis in rats: effect of the β3-adrenoceptor agonist SR58611A

    Science.gov (United States)

    Vasina, Valentina; Giannone, Ferdinando; Domenicali, Marco; Latorre, Rocco; Berzigotti, Annalisa; Caraceni, Paolo; Zoli, Marco; De Ponti, Fabrizio; Bernardi, Mauro

    2012-01-01

    BACKGROUND AND PURPOSE β3-Adrenoceptors participate in the regulation of vascular tone in physiological and pathological conditions. We aimed to assess the effect of pharmacological modulation of β3-adrenoceptors on portal pressure (PP) and systemic haemodynamics and their expression in the liver and mesenteric vessels of cirrhotic rats. EXPERIMENTAL APPROACH PP, central venous pressure (CVP) and systemic haemodynamics were invasively assessed in control and CCl4-treated cirrhotic rats before and during infusion of the selective β3-adrenoceptor agonist, SR58611A. Tissue samples were also collected from liver, heart, portal vein and mesenteric artery for immunohistochemistry and molecular biology analysis. The effect of SR58611A on isolated portal vein was assessed. KEY RESULTS At baseline, cirrhotic rats showed portal hypertension, reduced CVP and hyperdynamic circulation. SR58611A induced a significant, dose-dependent decrease in PP in cirrhotic rats, but not in controls. Although both groups manifested a dose-dependent reduction in mean arterial pressure, this effect was associated with decreased cardiac index (CI) and unchanged indicized peripheral vascular resistance (PVRI) in cirrhotic rats and increased CI and decreased PVRI in control animals. Pretreatment with the selective β3-adrenoceptor antagonist SR59230 prevented all SR58611A-induced changes in cirrhotic rats. SR58611A concentration-dependently relaxed portal vein in cirrhotic rats to a significantly greater extent than in healthy rats; pretreatment with SR59230A completely prevented SR58611A-induced cirrhotic portal vein relaxation. Finally, β3-adrenoceptors were identified in the liver, heart and portal vein of cirrhotic and control animals; their expression was increased in cirrhotic rats. CONCLUSIONS AND IMPLICATIONS β3-Adrenoceptors are altered in portal hypertension of experimental cirrhosis and may represent a novel therapeutic target. PMID:22708587

  4. ASKME Enterprise Portal (internal) -

    Data.gov (United States)

    Department of Transportation — The ASKME Enterprise Portal Internal (AEPi) is envisioned to be an integrated, single-point-of-entry solution that contains modular components. The AEPi will provide...

  5. ELECTRONIC COMMERCE PORTAL

    OpenAIRE

    Georgeta Soava

    2011-01-01

    Today companies are faced with the need to exploit technology changing computer environments, in order to improve customer satisfaction and reduce costs. A successful approach to electronic portals is an effective demonstration of the new ways of relating to the client. The objectives that we have considered for the realization of e-commerce portal can be summarized as follows: structured communication, effective collaboration, complet and closed circuit of orders and deliveries, inventory op...

  6. FINAL IMPLEMENTATION AND PERFORMANCE OF THE LHC COLLIMATOR CONTROL SYSTEM

    CERN Document Server

    Redaelli, S; Masi, A; Losito, R

    2009-01-01

    The 2008 collimation system of the CERN Large Hadron Collider (LHC) included 80 movable collimators for a total of 316 degrees of freedom. Before beam operation, the final controls implementation was deployed and commissioned. The control system enabled remote control and appropriate diagnostics of the relevant parameters. The collimator motion is driven with time-functions, synchronized with other accelerator systems, which allows controlling the collimator jaw positions with a micrometer accuracy during all machine phases. The machine protection functionality of the system, which also relies on function-based tolerance windows, was also fully validated. The collimator control challenges are reviewed and the final system architecture is presented. The results of the remote system commissioning and the overall performance are discussed.

  7. Evaluation of portal hypertension by MR portography

    International Nuclear Information System (INIS)

    Nagaoka, Shirou; Hagiwara, Masaru; Imanisi, Yosimasa

    1997-01-01

    Seventy-eight examinations of MR portography were totally performed in 24 controls and 33 patients with esophageal varices. Portal vein, SMV, hepatic vein, and IVC were entirely depicted in 21, 24, 22, and 24, respectively, of the 24 controls. As to intrahepatic upward branches of portal vein in the right lobe of the liver, the 4th branch was at least depicted in all of the 24. Although the portal vein trunk and SMV were entirely depicted in all of the 8 patients without treatment and liver dysfunction of Child A, there was no depiction of them in 1 of the 8 patients with liver dysfunction of Child B, and 1 of 5 patients with liver dysfunction of Child C. The 4th upward branch of portal vein in the right lobe of the liver was depicted in none of the 33 patients. Besides, none of the intrahepatic portal branches were depicted in 1 of 8 patients without treatment and liver dysfunction of Child B, and 1 of the 5 patients without treatment and liver dysfunction of Child C. There was a significant difference of depicted terminal upward branch of portal vein between the controls and patients without any treatment. In the patients without any significant difference of depicted terminal upward branch of portal vein was also present between Child's classification A and Child's classification B and C. Gastric coronary vein varices were detected by MR portography is 18 of 19 patients without treatment on the esophageal varices, and paraesophageal/esophageal varices were also depicted by MR portography in 13 of the 19. The collaterals were depicted by MR portography in all of the 6 patients with recurrent collaterals after Hassab's operation or splenectomy. MR portography was able to depict flow in trunk branches and collaterals of the portal vein system in a physiological state. (K.H.)

  8. Evaluation of portal hypertension by MR portography

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shirou; Hagiwara, Masaru; Imanisi, Yosimasa [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1997-02-01

    Seventy-eight examinations of MR portography were totally performed in 24 controls and 33 patients with esophageal varices. Portal vein, SMV, hepatic vein, and IVC were entirely depicted in 21, 24, 22, and 24, respectively, of the 24 controls. As to intrahepatic upward branches of portal vein in the right lobe of the liver, the 4th branch was at least depicted in all of the 24. Although the portal vein trunk and SMV were entirely depicted in all of the 8 patients without treatment and liver dysfunction of Child A, there was no depiction of them in 1 of the 8 patients with liver dysfunction of Child B, and 1 of 5 patients with liver dysfunction of Child C. The 4th upward branch of portal vein in the right lobe of the liver was depicted in none of the 33 patients. Besides, none of the intrahepatic portal branches were depicted in 1 of 8 patients without treatment and liver dysfunction of Child B, and 1 of the 5 patients without treatment and liver dysfunction of Child C. There was a significant difference of depicted terminal upward branch of portal vein between the controls and patients without any treatment. In the patients without any significant difference of depicted terminal upward branch of portal vein was also present between Child`s classification A and Child`s classification B and C. Gastric coronary vein varices were detected by MR portography is 18 of 19 patients without treatment on the esophageal varices, and paraesophageal/esophageal varices were also depicted by MR portography in 13 of the 19. The collaterals were depicted by MR portography in all of the 6 patients with recurrent collaterals after Hassab`s operation or splenectomy. MR portography was able to depict flow in trunk branches and collaterals of the portal vein system in a physiological state. (K.H.)

  9. Large vehicle portal monitor for perimeter safeguards applications

    International Nuclear Information System (INIS)

    Caldwell, J.T.; Atwater, H.F.; Bernard, W.; Bieri, J.M.; Shunk, E.R.

    1979-01-01

    We have developed a class of vehicle portal monitors based on shielded 4π geometry neutron counting. we have derived and experimentally verified an analytical expression relating the detection sensitivity of the neutron tunnel vehicle portal monitor to four design parameters of the system. For a given number of neutron detectors, this design achieves one or more orders of magnitude improvement in nuclear materials detection sensitivity over previous vehicle portal monitors

  10. Multidetector CT portal venography in evaluation of portosystemic collateral vessels

    International Nuclear Information System (INIS)

    Agarwal, A.; Jain, M.

    2008-01-01

    This essay shows the usefulness of multidetector CT angiography for evaluation of the splenoportal venous system, which is essential in the management of patients with portal hypertension and its complications, such as portal vein thrombosis. By providing scanning with reconstruction of thin axial source images and reformatting into thicker multiplanar reformats, multidetector CT can help to determine the extent and location of portosystemic collateral vessels in patients with portal hypertension and is probably the optimal imaging technique in this setting.

  11. Development of authentication system for the fast critical assembly (FCA) portal monitor (P/M) and penetration monitor (PN/M) systems of JAERI

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko

    1999-05-01

    The advanced comprehensive containment and surveillance system for the Fast Critical Assembly facility (FCA) of the Japan Atomic Energy Research Institute (JAERI) consists of a Portal monitor (P/M) and a Penetration Monitor (PN/M) systems. The development of these systems was completed in 1988 for alleviating the burdens of manpower and radiation problems in the frequent NDA inspections. After the completion of the field trial test (Phase III), in 1990, the International Atomic Energy Agency (IAEA) accepted the system on condition that an independent IAEA authentication equipment would be provided. The development of the authentication measures was carried out jointly by both the Japan Support Programme for Agency Safeguards (JASPAS) and the U.S. Program of Technical Assistance to IAEA Safeguards (POTAS), and also under the research agreement for the safeguards research and development between JAERI and the US Department of Energy (USDOE). The concept and design requirements of the authentication system were developed by IAEA, but the design and development of the authentication equipment were jointly funded both by JASPAS and POTAS, and also the fund of JAERI was provided for the Sandia National Laboratories (SNL) through USDOE. SNL developed and constructed the authentication system in two phase as Phase I and Phase II. JAERI financed the development of the Phase I and Phase II hardware and software, and the installation of the authentication equipment at the FCA facility, and also carried out the modification of the circuitry and devices for both the P/M and the PN/M systems as well as the reconstruction of the PN/M Junction Unit for compatibility with the implementation of the authentication measures. After the completion of consecutive field trial test of the P/M, the PN/M and the authentication system, IAEA accepted the entire system as an effective and efficient routine inspection measures in 1996. This report describes the modification and reconstruction of

  12. Next Gen One Portal Usability Evaluation

    Science.gov (United States)

    Cross, E. V., III; Perera, J. S.; Hanson, A. M.; English, K.; Vu, L.; Amonette, W.

    2018-01-01

    Each exercise device on the International Space Station (ISS) has a unique, customized software system interface with unique layouts / hierarchy, and operational principles that require significant crew training. Furthermore, the software programs are not adaptable and provide no real-time feedback or motivation to enhance the exercise experience and/or prevent injuries. Additionally, the graphical user interfaces (GUI) of these systems present information through multiple layers resulting in difficulty navigating to the desired screens and functions. These limitations of current exercise device GUI's lead to increased crew time spent on initiating, loading, performing exercises, logging data and exiting the system. To address these limitations a Next Generation One Portal (NextGen One Portal) Crew Countermeasure System (CMS) was developed, which utilizes the latest industry guidelines in GUI designs to provide an intuitive ease of use approach (i.e., 80% of the functionality gained within 5-10 minutes of initial use without/limited formal training required). This is accomplished by providing a consistent interface using common software to reduce crew training, increase efficiency & user satisfaction while also reducing development & maintenance costs. Results from the usability evaluations showed the NextGen One Portal UI having greater efficiency, learnability, memorability, usability and overall user experience than the current Advanced Resistive Exercise Device (ARED) UI used by astronauts on ISS. Specifically, the design of the One-Portal UI as an app interface similar to those found on the Apple and Google's App Store, assisted many of the participants in grasping the concepts of the interface with minimum training. Although the NextGen One-Portal UI was shown to be an overall better interface, observations by the test facilitators noted specific exercise tasks appeared to have a significant impact on the NextGen One-Portal UI efficiency. Future updates to

  13. Plant systems/components modularization study. Final report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    1977-07-01

    The final results are summarized of a Plant Systems/Components Modularization Study based on Stone and Webster's Pressurized Water Reactor Reference Design. The program has been modified to include evaluation of the most promising areas for modular consideration based on the level of the Sundesert Project engineering design completion and the feasibility of their incorporation into the plant construction effort.

  14. ASBESTOS PIPE-INSULATION REMOVAL ROBOT SYSTEM; FINAL

    International Nuclear Information System (INIS)

    Unknown

    2000-01-01

    This final topical report details the development, experimentation and field-testing activities for a robotic asbestos pipe-insulation removal robot system developed for use within the DOE's weapon complex as part of their ER and WM program, as well as in industrial abatement. The engineering development, regulatory compliance, cost-benefit and field-trial experiences gathered through this program are summarized

  15. Plant systems/components modularization study. Final report

    International Nuclear Information System (INIS)

    1977-07-01

    The final results are summarized of a Plant Systems/Components Modularization Study based on Stone and Webster's Pressurized Water Reactor Reference Design. The program has been modified to include evaluation of the most promising areas for modular consideration based on the level of the Sundesert Project engineering design completion and the feasibility of their incorporation into the plant construction effort

  16. A conceptual design of Final Focus Systems for linear colliders

    International Nuclear Information System (INIS)

    Brown, K.L.

    1987-06-01

    Linear colliders are a relatively recent development in the evolution of particle accelerators. This report discusses some of the approaches that have been considered for the design of Final Focus Systems to demagnify the beam exiting from a linac to the small size suitable for collisions at the interaction point. The system receiving the most attention is the one adopted for the SLAC Linear Collider. However, the theory and optical techniques discussed should be applicable to the design efforts for future machines

  17. Beam dynamics in the SLC final focus system

    International Nuclear Information System (INIS)

    Bambade, P.S.

    1987-06-01

    The SLC luminosity is reached by colliding beams focused to about 2 μm transverse sizes. The Final Focus System (FFS) must enable, beyond its basic optical design, the detection and correction of errors accumulated in the system. In this paper, after summarizing the design, we review the sensitivity to such errors and the ability to correct them. The overall tuning strategy involves three phases: single beam spot minimization, steering the beams in collision and luminosity optimization with beam-beam effects

  18. The Final Focus Test Beam laser referene system

    International Nuclear Information System (INIS)

    Bressler, V.E.; Ruland, R.E.

    1993-05-01

    The original design for the SLAC linac included an alignment reference system with 270 diffraction gratings situated along the 3000 meter linac. These gratings have provided SLAC with a global reference line repeatable to within 200 micro meters. For the Final Focus Test Beam, this laser system has been extended and 13 new diffraction gratings have been installed. Improvements targets and the availability of new instruments allows us to evaluate the performance of the laser reference system at the 510 micro meter level. An explanation of the system and the results of our evaluation are presented

  19. Quantitative vs. subjective portal verification using digital portal images

    International Nuclear Information System (INIS)

    Bissett, Randy; Leszczynski, Konrad; Loose, Stephen; Boyko, Susan; Dunscombe, Peter

    1996-01-01

    Purpose: Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Methods and Materials: Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamber matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. Results: All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 deg. . For all

  20. A newborn liver mass that never existed: a somber reminder of embryonic ties between umbilical vein and portal venous system

    Directory of Open Access Journals (Sweden)

    Haafiz A

    2011-12-01

    Full Text Available Allah Haafiz1, Jonathan L Williams2, Joel M Andres1, Don A Novak11Pediatric Gastroenterology, Hepatology; 2Department of Pediatric Radiology, University of Florida College of Medicine, Gainesville, FL, USAAbstract: A 6-day-old, known to have transposition of the great vessels, received care in the neonatal intensive care unit at a tertiary care center. A computed tomography scan was performed for abdominal distention and upper gastrointestinal bleeding, which revealed a “mass lesion” in the left liver lobe. Analysis of antecedent events and the clinical and laboratory course uncovered an iatrogenic etiology and pathogenesis of the lesion. As the nature of the lesion was clarified, no specific therapy was required. This case is presented to show a serious yet preventable complication of a commonly performed procedure.Keywords: portal vein thrombosis, liver mass, umbilical venous catheter

  1. A RECIPE FOR LINEAR COLLIDER FINAL FOCUS SYSTEM DESIGN

    International Nuclear Information System (INIS)

    Seryi, Andrei

    2003-01-01

    The design of Final Focus systems for linear colliders is challenging because of the large demagnifications needed to produce nanometer-sized beams at the interaction point. Simple first- and second-order matrix matching have proven insufficient for this task, and minimization of third- and higher-order aberrations is essential. An appropriate strategy is required for the latter to be successful. A recipe for Final Focus design, and a set of computational tools used to implement this approach, are described herein. An example of the use of this procedure is given

  2. Probing LINEAR Collider Final Focus Systems in SuperKEKB

    CERN Document Server

    Thrane, Paul Conrad Vaagen

    2017-01-01

    A challenge for future linear collider final focus systems is the large chromaticity produced by the final quadrupoles. SuperKEKB will be correcting high levels of chromaticity using the traditional scheme which has been also proposed for the CLIC FFS. We present early simulation results indicating that lowering β*у in the SuperKEKB Low Energy Ring might be possible given on-axis injection and low bunch current, opening the possibility of testing chromaticity correction beyond FFTB level, similar to ILC and approaching that of CLIC. CLIC – Note – 1077

  3. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis.

    Science.gov (United States)

    Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo

    2005-06-07

    To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

  4. Congenital absence of the portal vein presenting as pulmonary hypertension

    International Nuclear Information System (INIS)

    Jun, Sur Young; Lee, Whal; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One; Yeon, Kyung Mo

    2007-01-01

    Congenital absence of the portal vein (CAPV) is a rare malformation in which intestinal and splenic venous flow bypasses the liver and drains directly into the systemic circulation via a congenital portosystemic shunt. We describe two cases of CAPV presenting as pulmonary hypertension that were initially suspected as primary pulmonary hypertension. However, subsequent ultrasonography and CT detected the absence of a portal vein and the presence of a portosystemic shunt. Pulmonary hypertension is a recognized complication of liver disease and portal hypertension. However, these two cases illustrate that CAPV may result in pulmonary hypertension without liver disease or portal hypertension

  5. Congenital absence of the portal vein presenting as pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Sur Young; Lee, Whal; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One; Yeon, Kyung Mo [Seoul National University Hospital, Seoul (Korea, Republic of)

    2007-11-15

    Congenital absence of the portal vein (CAPV) is a rare malformation in which intestinal and splenic venous flow bypasses the liver and drains directly into the systemic circulation via a congenital portosystemic shunt. We describe two cases of CAPV presenting as pulmonary hypertension that were initially suspected as primary pulmonary hypertension. However, subsequent ultrasonography and CT detected the absence of a portal vein and the presence of a portosystemic shunt. Pulmonary hypertension is a recognized complication of liver disease and portal hypertension. However, these two cases illustrate that CAPV may result in pulmonary hypertension without liver disease or portal hypertension.

  6. Pregnancy with Portal Hypertension

    Science.gov (United States)

    Aggarwal, Neelam; Negi, Neha; Aggarwal, Aakash; Bodh, Vijay; Dhiman, Radha K.

    2014-01-01

    Even though pregnancy is rare with cirrhosis and advanced liver disease, but it may co-exist in the setting of non-cirrhotic portal hypertension as liver function is preserved but whenever encountered together is a complex clinical dilemma. Pregnancy in a patient with portal hypertension presents a special challenge to the obstetrician as so-called physiological hemodynamic changes associated with pregnancy, needed for meeting demands of the growing fetus, worsen the portal hypertension thereby putting mother at risk of potentially life-threatening complications like variceal hemorrhage. Risks of variceal bleed and hepatic decompensation increase many fold during pregnancy. Optimal management revolves round managing the portal hypertension and its complications. Thus management of such cases requires multi-speciality approach involving obstetricians experienced in dealing with high risk cases, hepatologists, anesthetists and neonatologists. With advancement in medical field, pregnancy is not contra-indicated in these women, as was previously believed. This article focuses on the different aspects of pregnancy with portal hypertension with special emphasis on specific cause wise treatment options to decrease the variceal bleed and hepatic decompensation. Based on extensive review of literature, management from pre-conceptional period to postpartum is outlined in order to have optimal maternal and perinatal outcomes. PMID:25755552

  7. The NOAO NVO Portal

    Science.gov (United States)

    Miller, C. J.; Gasson, D.; Fuentes, E.

    2007-10-01

    The NOAO NVO Portal is a web application for one-stop discovery, analysis, and access to VO-compliant imaging data and services. The current release allows for GUI-based discovery of nearly a half million images from archives such as the NOAO Science Archive, the Hubble Space Telescope WFPC2 and ACS instruments, XMM-Newton, Chandra, and ESO's INT Wide-Field Survey, among others. The NOAO Portal allows users to view image metadata, footprint wire-frames, FITS image previews, and provides one-click access to science quality imaging data throughout the entire sky via the Firefox web browser (i.e., no applet or code to download). Users can stage images from multiple archives at the NOAO NVO Portal for quick and easy bulk downloads. The NOAO NVO Portal also provides simplified and direct access to VO analysis services, such as the WESIX catalog generation service. We highlight the features of the NOAO NVO Portal (http://nvo.noao.edu).

  8. Radioisotopic flow scanning for portal blood flow and portal hypertension

    International Nuclear Information System (INIS)

    Hesdorffer, C.S.; Bezwoda, W.R.; Danilewitz, M.D.; Esser, J.D.; Tobias, M.

    1987-01-01

    The use of a simple, noninvasive, isotope scanning technique for the determination of relative portal blood flow and detection of portal hypertension is described. Using this technique the presence of portal hypertension was demonstrated in seven of nine patients known to have elevated portal venous pressure. By contrast, esophageal varices were demonstrated in only five of these patients, illustrating the potential value of the method. Furthermore, this technique has been adapted to the study of portal blood flow in patients with myeloproliferative disorders with splenomegaly but without disturbances in hepatic architecture. Results demonstrate that the high relative splenic flow resulting from the presence of splenomegaly may in turn be associated with elevated relative portal blood flow and portal hypertension. The theoretic reasons for the development of flow-related portal hypertension and its relationship to splenic blood flow are discussed

  9. The cumulative verification image analysis tool for offline evaluation of portal images

    International Nuclear Information System (INIS)

    Wong, John; Yan Di; Michalski, Jeff; Graham, Mary; Halverson, Karen; Harms, William; Purdy, James

    1995-01-01

    Purpose: Daily portal images acquired using electronic portal imaging devices contain important information about the setup variation of the individual patient. The data can be used to evaluate the treatment and to derive correction for the individual patient. The large volume of images also require software tools for efficient analysis. This article describes the approach of cumulative verification image analysis (CVIA) specifically designed as an offline tool to extract quantitative information from daily portal images. Methods and Materials: The user interface, image and graphics display, and algorithms of the CVIA tool have been implemented in ANSCI C using the X Window graphics standards. The tool consists of three major components: (a) definition of treatment geometry and anatomical information; (b) registration of portal images with a reference image to determine setup variation; and (c) quantitative analysis of all setup variation measurements. The CVIA tool is not automated. User interaction is required and preferred. Successful alignment of anatomies on portal images at present remains mostly dependent on clinical judgment. Predefined templates of block shapes and anatomies are used for image registration to enhance efficiency, taking advantage of the fact that much of the tool's operation is repeated in the analysis of daily portal images. Results: The CVIA tool is portable and has been implemented on workstations with different operating systems. Analysis of 20 sequential daily portal images can be completed in less than 1 h. The temporal information is used to characterize setup variation in terms of its systematic, random and time-dependent components. The cumulative information is used to derive block overlap isofrequency distributions (BOIDs), which quantify the effective coverage of the prescribed treatment area throughout the course of treatment. Finally, a set of software utilities is available to facilitate feedback of the information for

  10. ERNIE performance with TSA portals Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Labov, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2018-01-05

    This project extends the “Enhanced Radiological Nuclear Inspection and Evaluation” (ERNIE) system developed with CBP and DNDO to improve performance of PVT-based Radiation Portal Monitors (RPMs). ERNIE was designed to be used with any RPM system. The first implementation was with the SAIC (Leidos) RPM-8 systems. In this project, we are demonstrating how effective the ERNIE approach can be when applied to the VM250 TSA portals used in NSDD programs. Part of the challenge in adapting ERNIE to handle VM250 portals is the lack of gamma spectral information. We report here on the first results showing how the ERNIE analysis can improve analysis of measurements with the VM250 RPMs.

  11. Plutonium Protection System (PPS). Volume 2. Hardware description. Final report

    International Nuclear Information System (INIS)

    Miyoshi, D.S.

    1979-05-01

    The Plutonium Protection System (PPS) is an integrated safeguards system developed by Sandia Laboratories for the Department of Energy, Office of Safeguards and Security. The system is designed to demonstrate and test concepts for the improved safeguarding of plutonium. Volume 2 of the PPS final report describes the hardware elements of the system. The major areas containing hardware elements are the vault, where plutonium is stored, the packaging room, where plutonium is packaged into Container Modules, the Security Operations Center, which controls movement of personnel, the Material Accountability Center, which maintains the system data base, and the Material Operations Center, which monitors the operating procedures in the system. References are made to documents in which details of the hardware items can be found

  12. Arachidonic acid metabolites and endothelial dysfunction of portal hypertension.

    Science.gov (United States)

    Sacerdoti, David; Pesce, Paola; Di Pascoli, Marco; Brocco, Silvia; Cecchetto, Lara; Bolognesi, Massimo

    2015-07-01

    Increased resistance to portal flow and increased portal inflow due to mesenteric vasodilatation represent the main factors causing portal hypertension in cirrhosis. Endothelial cell dysfunction, defined as an imbalance between the synthesis, release, and effect of endothelial mediators of vascular tone, inflammation, thrombosis, and angiogenesis, plays a major role in the increase of resistance in portal circulation, in the decrease in the mesenteric one, in the development of collateral circulation. Reduced response to vasodilators in liver sinusoids and increased response in the mesenteric arterioles, and, viceversa, increased response to vasoconstrictors in the portal-sinusoidal circulation and decreased response in the mesenteric arterioles are also relevant to the pathophysiology of portal hypertension. Arachidonic acid (AA) metabolites through the three pathways, cyclooxygenase (COX), lipoxygenase, and cytochrome P450 monooxygenase and epoxygenase, are involved in endothelial dysfunction of portal hypertension. Increased thromboxane-A2 production by liver sinusoidal endothelial cells (LSECs) via increased COX-1 activity/expression, increased leukotriens, increased epoxyeicosatrienoic acids (EETs) (dilators of the peripheral arterial circulation, but vasoconstrictors of the portal-sinusoidal circulation), represent a major component in the increased portal resistance, in the decreased portal response to vasodilators and in the hyper-response to vasoconstrictors. Increased prostacyclin (PGI2) via COX-1 and COX-2 overexpression, and increased EETs/heme-oxygenase-1/K channels/gap junctions (endothelial derived hyperpolarizing factor system) play a major role in mesenteric vasodilatation, hyporeactivity to vasoconstrictors, and hyper-response to vasodilators. EETs, mediators of liver regeneration after hepatectomy and of angiogenesis, may play a role in the development of regenerative nodules and collateral circulation, through stimulation of vascular endothelial

  13. Assessment of the Manufacturing Possibility of Thin-Walled Robotic Portals for Conveyor Worklace

    Directory of Open Access Journals (Sweden)

    Peter Michalik

    2018-03-01

    Full Text Available The paper discusses evaluation of machining solutions for oversized thin-walled robotic portal component for conveyance workplaces. The following portal CNC machining centers have been selected. Firstly, a FSGC 300 “portal type” portal was proposed, with a 50000 mm “X” axis and Heidenhain control system, the second portal was a DMU 340 portal with the maximum axis “X” of 6000 mm and Siemens Sinumerik control system and the last portal was the VF-10 / 40 one, with the maximum axis “X” of 3048 mm and Fanuc control system. Further, the method of fixing a thin-walled robotic portal is designed and individual options are evaluated for their economy. The CAM software application used for programming the production was SolidWorks.

  14. Simulated coal gas MCFC power plant system verification. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-07-30

    The objective of the main project is to identify the current developmental status of MCFC systems and address those technical issues that need to be resolved to move the technology from its current status to the demonstration stage in the shortest possible time. The specific objectives are separated into five major tasks as follows: Stack research; Power plant development; Test facilities development; Manufacturing facilities development; and Commercialization. This Final Report discusses the M-C power Corporation effort which is part of a general program for the development of commercial MCFC systems. This final report covers the entire subject of the Unocal 250-cell stack. Certain project activities have been funded by organizations other than DOE and are included in this report to provide a comprehensive overview of the work accomplished.

  15. Columbia River system operation review. Final environmental impact statement

    International Nuclear Information System (INIS)

    1995-11-01

    This Appendix C of the Final Environmental Impact Statement for the Columbia River System discusses impacts on andromous fish and juvenile fish transportation. The principal andromous fish in the Columbia basin include salmonid species (Chinook, coho, and sockeye salmon, and steelhead) and nonsalmoinid andromous species (sturgeon, lamprey, and shad). Major sections in this document include the following: background, scope and process; affected environment for salmon and steelhead, shaded, lamprey, sturgeon; study methods; description of alternatives: qualitative and quantitative findings

  16. Personalization Methods for Internet Portals

    OpenAIRE

    Barbara Dębska; Agnieszka Kubacka

    2012-01-01

    The article presents methods of acquiring and gathering data about users of internet portals, with particular emphasis on educational portals. Definitions, aims and tasks related to the process of personalization of e-learning portals are thoroughly discussed. So are knowledge acquisition techniques applied in personalization, especially artificial intelligence methods.

  17. R2 Water Quality Portal Monitoring Stations

    Science.gov (United States)

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  18. Evolution of portal hypertension and mechanisms involved in its maintenance in a rat model

    International Nuclear Information System (INIS)

    Sikuler, E.; Kravetz, D.; Groszmann, R.J.

    1985-01-01

    In rats with portal hypertension induced by partial ligation of the portal vein, the authors have recently demonstrated an increased portal venous inflow that becomes an important factor in the maintenance of portal hypertension. The sequence of events that leads into this circulatory disarray is unknown. The authors evaluated chronologically the chain of hemodynamic changes that occurred after portal hypertension was induced by partial ligation of the portal vein. In this model it is possible to follow, from the initiation of the portal-hypertensive state, the interaction between blood flow and resistance in the portal system as well as the relation between the development of portal-systemic shunting and the elevated portal venous inflow. The study was performed in 45 portal-hypertensive rats and in 29 sham-operated rats. Blood flow and portal-systemic shunting were measured by radioactive microsphere techniques. The constriction of the portal vein was immediately followed by a resistance-induced portal hypertension characterized by increased portal resistance (9.78 +/- 0.89 vs. 4.18 +/- 0.71 dyn X s X cm-5 X 10(4), mean +/- SE, P less than 0.01), increased portal pressure (17.7 +/- 0.9 vs. 9.5 +/- 0.6 mmHg, P less than 0.001), and decreased portal venous inflow (3.93 +/- 0.26 vs. 6.82 +/- 0.49 ml X min-1 X 100 g body wt-1, P less than 0.001)

  19. Measuring Campus Portal Effectiveness and the Contributing Factors

    Science.gov (United States)

    Masrek, Mohamad Noorman bin

    2007-01-01

    Purpose: The purpose of the paper is to evaluate the effectiveness or success of universities' portal implementation from the perspective of students as users. Adopting the model developed by Delone and McLean, portal effectiveness is defined as being composed of information quality, systems quality and service quality. In addition, the paper also…

  20. A Dynamic Alignment System for the Final Focus Test Beam

    International Nuclear Information System (INIS)

    Ruland, R.E.; Bressler, V.E.; Fischer, G.; Plouffe, D.; SLAC

    2005-01-01

    The Final Focus Test Beam (FFTB) was conceived as a technological stepping stone on the way to the next linear collider. Nowhere is this more evident than with the alignment subsystems. Alignment tolerances for components prior to beam turn are almost an order of magnitude smaller than for previous projects at SLAC. Position monitoring systems which operate independent of the beam are employed to monitor motions of the components locally and globally with unprecedented precision. An overview of the FFTB alignment system is presented herein

  1. Extrahepatic complications to cirrhosis and portal hypertension

    DEFF Research Database (Denmark)

    Møller, Søren; Henriksen, Jens H; Bendtsen, Flemming

    2014-01-01

    In addition to complications relating to the liver, patients with cirrhosis and portal hypertension develop extrahepatic functional disturbances of multiple organ systems. This can be considered a multiple organ failure that involves the heart, lungs, kidneys, the immune systems, and other organ...

  2. The Learning Portal

    Science.gov (United States)

    Staudt, Carolyn; Hanzlick-Burton, Camden; Williamson, Carol; McIntyre, Cynthia

    2015-01-01

    The Innovative Technology in Science Inquiry (ITSI) project is a learning portal with hundreds of free, customizable science, math, and engineering activities funded by the National Science Foundation at the Concord Consortium, a nonprofit research and development organization dedicated to transforming education through technology. The project…

  3. BRAZILIAN NEWS PORTALS CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    Heloiza G. Herckovitz

    2011-02-01

    Full Text Available A content analysis of four Brazilian news media portals found that economic news dominated the top headlines with little attention paid to education, the environment and welfare. Other trends included a focus on local events and national news sources, reliance on few sources, mostly official ones, and a low percentage of news that fitted the concept of newsworthiness (a combination of both social significance and deviance concepts. Other findings of a study of 432 top news stories published by UOL, Estadão, iG and Terra during a 15-day period between February and March 2008 indicate that the top portions of the portals’ front pages carry news that lacks story depth, editorial branding, and multimedia applications. The results suggest that online news portals are in their infancy although Brazil has the largest online population of Latin America. This study hopes to shed light on the gatekeeping process in Brazilian news portals. Brazilian media portals have yet to become a significant editorial force able to provide knowledge about social issues and public affairs in a socially responsible fashione.

  4. Metabolic effects of portal vein sensing.

    Science.gov (United States)

    Mithieux, G

    2014-09-01

    The extrinsic gastrointestinal nerves are crucial in the sensing of nutrients and hormones and its translation in terms of control of food intake. Major macronutrients like glucose and protein are sensed by the extrinsic nerves located in the portal vein walls, which signal to the brain and account for the satiety phenomenon they promote. Glucose is sensed in the portal vein by neurons expressing the glucose receptor SGLT3, which activate the main regions of the brain involved in the control of food intake. Proteins indirectly act on food intake by inducing intestinal gluconeogenesis and its sensing by the portal glucose sensor. The mechanism involves a prior antagonism by peptides of the μ-opioid receptors present in the portal vein nervous system and a reflex arc with the brain inducing intestinal gluconeogenesis. In a comparable manner, short-chain fatty acids produced from soluble fibre act via intestinal gluconeogenesis to exert anti-obesity and anti-diabetic effects. In the case of propionate, the mechanism involves a prior activation of the free fatty acid receptor FFAR3 present in the portal nerves and a reflex arc initiating intestinal gluconeogenesis. © 2014 John Wiley & Sons Ltd.

  5. Interactive monitoring portal for fusion simulations

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D.P.; Kim, E.N.; Flanagan, S.M.; Lee, X.

    2012-01-01

    Highlights: ► We designed a web-based monitoring system that tracks the status of fusion simulations. ► Our system is scalable to monitor the simulations running on distributed supercomputers and clusters located at multiple geographical locations. ► The monitoring portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. ► Our system utilizes the open source software, such as Python, Django, MySQL, Apache, and MDSplus. - Abstract: The Center for Simulation of RF Wave Interactions with Magnetohydrodynamics (SWIM) Project is a proto-Fusion Simulation Program (FSP) whose goal is to study high-performance fusion plasmas and perform comprehensive simulations that are essential to the development of fusion. SWIM team members are geographically distributed and utilize distributed supercomputers for computational simulations. Due to the highly distributed computational work environment, the SWIM team has the difficulty of monitoring code runs and discovering historical runs. To alleviate this difficulty a web-based monitoring portal has been developed and deployed. The monitoring portal tracks the progress of simulations and automatically collects metadata in real-time. This capability helps scientists to effectively utilize precious computer resources. Furthermore, the portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. The user interface provides rapid discovery capability via multi-field searching and sorting. The development of the monitoring portal used open source software, such as Python, Django, MySQL, and Apache. It uses MDSplus for data management, Memcached for data caches, and OpenID for single sign-on security. This paper describes the software architecture, related technologies and deployment experiences of the monitoring portal.

  6. Wall shear stress in portal vein of cirrhotic patients with portal hypertension.

    Science.gov (United States)

    Wei, Wei; Pu, Yan-Song; Wang, Xin-Kai; Jiang, An; Zhou, Rui; Li, Yu; Zhang, Qiu-Juan; Wei, Ya-Juan; Chen, Bin; Li, Zong-Fang

    2017-05-14

    To investigate wall shear stress (WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. Idealized portal vein (PV) system models were reconstructed with different angles of the PV-splenic vein (SV) and superior mesenteric vein (SMV)-SV. Patient-specific models were created according to enhanced computed tomography images. WSS was simulated by using a finite-element analyzer, regarding the blood as a Newtonian fluid and the vessel as a rigid wall. Analysis was carried out to compare the WSS in the portal hypertension group with that in healthy controls. For the idealized models, WSS in the portal hypertension group (0-10 dyn/cm 2 ) was significantly lower than that in the healthy controls (10-20 dyn/cm 2 ), and low WSS area (0-1 dyn/cm 2 ) only occurred in the left wall of the PV in the portal hypertension group. Different angles of PV-SV and SMV-SV had different effects on the magnitude and distribution of WSS, and low WSS area often occurred in smaller PV-SV angle and larger SMV-SV angle. In the patient-specific models, WSS in the cirrhotic patients with portal hypertension (10.13 ± 1.34 dyn/cm 2 ) was also significantly lower than that in the healthy controls ( P portal hypertension, the low WSS area extended to wider levels and the magnitude of WSS reached lower levels, thereby being more prone to disturbed flow occurrence. Cirrhotic patients with portal hypertension show dramatic hemodynamic changes with lower WSS and greater potential for disturbed flow, representing a possible causative factor of PV thrombosis.

  7. Orthotopic liver transplantation for portosystemic encephalopathy in an adult with congenital absence of the portal vein

    NARCIS (Netherlands)

    Wojcicki, M; Haagsma, EB; Gouw, ASH; Slooff, MJH; Porte, RJ

    Congenital absence of the portal vein (CAPV) is a very rare venous malformation in which mesenteric venous blood drains directly into the systemic circulation. There is no portal perfusion of the liver and no portal hypertension. This abnormality is usually coincidentally discovered in children, the

  8. Radionuclide assessment of portal hypertension syndrome

    International Nuclear Information System (INIS)

    Aliev, M.A.; Khusain, Sh.K.; Alpeisova, Sh.T.

    2005-01-01

    This paper presents review of radionuclide studies for portal hypertension patients. Presented results showed that portal hypertension signs were revealed for the first group patients. The signs become apparent by splenomegaly and increase of colloid accumulation in it. Accumulation of the chemical in spleen was evidence of ingestion rate increase of reticuloendothelial system owing to its hyperplasia as well as liver phagocytic activity decrease due to pathological paren-chematous process and inter liver blockade. The most typical scintigraphic signs of portal hypertension were determined according chemical accumulation decreased in spleen and marrow sequentially. It is determined radionuclide method contributes to assessment of structural and functional aberrations character in liver and spleen for cirrhosis patients. (author)

  9. Brayton isotope power system, phase I. Final report

    International Nuclear Information System (INIS)

    1978-01-01

    The Phase I program resulted in the development and ground demonstration of a dynamic power conversion system. The two key contractual objectives of 25% conversion efficiency and 1000 h of endurance testing were successfully met. As a result of the Phase I effort, the BIPS is a viable candidate for further development into a flight system capable of sustained operation in space. It represents the only known dynamic space power system to demonstrate the performance and endurance coupled with the simplicity necessary for reliable operation. This final report follows thirty-five monthly reports. For expediency, it makes liberal use of referenced documents which have been submitted to DOE during the course of the program

  10. Application of the smart portal in transportation

    International Nuclear Information System (INIS)

    Kercel, S.W.; Baylor, V.M.; Dress, W.B.; Hickerson, T.W.; Jatko, W.B.; Labaj, L.E.; Muhs, J.D.; Pack, R.M.

    1996-01-01

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developed a ''Portal-of-the-Future'', or ''smart portal''. This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiogram, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals

  11. Application of the smart portal in transportation

    Energy Technology Data Exchange (ETDEWEB)

    Kercel, S.W.; Baylor, V.M.; Dress, W.B.; Hickerson, T.W.; Jatko, W.B.; Labaj, L.E.; Muhs, J.D.; Pack, R.M.

    1996-12-31

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developed a ``Portal-of-the-Future``, or ``smart portal``. This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiogram, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals.

  12. Application of the smart portal in transportation

    Science.gov (United States)

    Kercel, Stephen W.; Baylor, Vivian M.; Dress, William B.; Hickerson, Tim W.; Jatko, William B.; Labaj, Leo E.; Muhs, Jeffrey D.; Pack, Richard M.

    1997-02-01

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developing a `Portal-of-the-Future', or `smart portal.' This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiograms, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals.

  13. Splanchnic-aortic inflammatory axis in experimental portal hypertension

    Science.gov (United States)

    Aller, Maria-Angeles; de las Heras, Natalia; Nava, Maria-Paz; Regadera, Javier; Arias, Jaime; Lahera, Vicente

    2013-01-01

    Splanchnic and systemic low-grade inflammation has been proposed to be a consequence of long-term prehepatic portal hypertension. This experimental model causes minimal alternations in the liver, thus making a more selective study possible for the pathological changes characteristic of prehepatic portal hypertension. Low-grade splanchnic inflammation after long-term triple partial portal vein ligation could be associated with liver steatosis and portal hypertensive intestinal vasculopathy. In fact, we have previously shown that prehepatic portal hypertension in the rat induces liver steatosis and changes in lipid and carbohydrate metabolism similar to those produced in chronic inflammatory conditions described in metabolic syndrome in humans. Dysbiosis and bacterial translocation in this experimental model suggest the existence of a portal hypertensive intestinal microbiome implicated in both the splanchnic and systemic alterations related to prehepatic portal hypertension. Among the systemic impairments, aortopathy characterized by oxidative stress, increased levels of proinflammatory cytokines and profibrogenic mediators stand out. In this experimental model of long-term triple portal vein ligated-rats, the abdominal aortic proinflammatory response could be attributed to oxidative stress. Thus, the increased aortic reduced-nicotinamide-adenine dinucleotide phosphate [NAD(P)H] oxidase activity could be associated with reactive oxygen species production and promote aortic inflammation. Also, oxidative stress mediated by NAD(P)H oxidase has been associated with risk factors for inflammation and atherosclerosis. The splanchnic and systemic pathology that is produced in the long term after triple partial portal vein ligation in the rat reinforces the validity of this experimental model to study the chronic low-grade inflammatory response induced by prehepatic portal hypertension. PMID:24307792

  14. Protective barrier systems for final disposal of Hanford Waste Sites

    International Nuclear Information System (INIS)

    Phillips, S.J.; Hartley, J.N.

    1986-01-01

    A protecting barrier system is being developed for potential application in the final disposal of defense wastes at the Hanford Site. The functional requirements for the protective barrier are control of water infiltration, wind erosion, and plant and animal intrusion into the waste zone. The barrier must also be able to function without maintenance for the required time period (up to 10,000 yr). This paper summarizes the progress made and future plans in this effort to design and test protective barriers at the Hanford Site

  15. Un Portal de Información Médica a través de un sistema de gestión de contenidos Web A Web Portal for Medical Information through a Web Content Management System

    Directory of Open Access Journals (Sweden)

    Yaisel Lorenzo Rodríguez

    2011-06-01

    Full Text Available El trabajo que se presenta da respuesta a las acciones de informatización de la Facultad de Ciencias Médicas en Guinea Ecuatorial. Se presentan los elementos que han condicionado la creación de la Red de Información Médica en Guinea Ecuatorial (GUIMED, a través de un gestor de contenidos en línea que facilita a partir del empleo de las tecnologías de la informática, las comunicaciones y los ambientes colaborativos accesibles hasta el momento. GUIMED, expresada en su portal Web, fue fundamentada por: una interfaz sencilla y amigable, un repositorio de información basado en el modelo cliente-servidor, capacidades de búsqueda, aula virtual para la enseñanza, administración sencilla e intuitiva y el control de la accesibilidad a la información.This paper responds to the actions to computerize the Medical School in Equatorial Guinea. The elements that have conditioned the creation of the Medical Information Net in Equatorial Guinea (GUIMED are presented through a content management on-line that facilitates the use of current information and communication technologies as well as accessible collaboration environments. GUIMED is supported in its Web portal by: a simple user-friendly interface, information repository based on a user-server model, search competence, virtual teaching-learning classroom, simple intuitive administration and the control of information accessibility.

  16. Altered blood-brain barrier permeability in rats with prehepatic portal hypertension turns to normal when portal pressure is lowered

    Science.gov (United States)

    Eizayaga, Francisco; Scorticati, Camila; Prestifilippo, Juan P; Romay, Salvador; Fernandez, Maria A; Castro, José L; Lemberg, Abraham; Perazzo, Juan C

    2006-01-01

    AIM: To study the blood-brain barrier integrity in prehepatic portal hypertensive rats induced by partial portal vein ligation, at 14 and 40 d after ligation when portal pressure is spontaneously normalized. METHODS: Adult male Wistar rats were divided into four groups: Group I: Sham14d , sham operated; Group II: PH14d , portal vein stenosis; (both groups were used 14 days after surgery); Group III: Sham40d, Sham operated and Group IV: PH40d Portal vein stenosis (Groups II and IV used 40 d after surgery). Plasma ammonia, plasma and cerebrospinal fluid protein and liver enzymes concentrations were determined. Trypan and Evans blue dyes, systemically injected, were investigated in hippocampus to study blood-brain barrier integrity. Portal pressure was periodically recorded. RESULTS: Forty days after stricture, portal pressure was normalized, plasma ammonia was moderately high, and both dyes were absent in central nervous system parenchyma. All other parameters were reestablished. When portal pressure was normalized and ammonia level was lowered, but not normal, the altered integrity of blood-brain barrier becomes reestablished. CONCLUSION: The impairment of blood-brain barrier and subsequent normalization could be a mechanism involved in hepatic encephalopathy reversibility. Hemodynamic changes and ammonia could trigger blood-brain barrier alterations and its reestablishment. PMID:16552803

  17. Portal Environment in Today’s Business

    OpenAIRE

    Aldubaikhi, Ammar

    2015-01-01

    Companies can get benefits from new business models as they can have better and efficient collaboration system and this can be derived from the discussed application in this paper. Companies that easily personalize the SAP enterprise portal are more productive and this reflects their interests in business

  18. Final design and status of the NSLS vacuum system

    International Nuclear Information System (INIS)

    Schuchman, J.C.

    1982-01-01

    We describe the final system, as built, reasons for changes and the general status of the NSLS. The NSLS is a dedicated facility for the purpose of producing synchrotron radiation. It consists of an electron linac-booster injector system, and two storage rings, one for uv research and the other for x-ray research. (Synchrotron radiation is produced by accelerating electrons in the storage rings.) The design current and energies are 1000 ma at 700 MeV for the vuv ring and 500 ma at 2.5 GeV for the x-ray ring. A total of 44 experimental beam ports are available for use. Since each beam port may be divided into two or more experimentall beam lines, it is quite plausible to have upward of 100 simultaneously operating beam lines

  19. Angiography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E

    1982-04-05

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology.

  20. Angiography in portal hypertension

    International Nuclear Information System (INIS)

    Zeitler, E.

    1982-01-01

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology. (orig.) [de

  1. Portal Annular Pancreas

    Science.gov (United States)

    Harnoss, Jonathan M.; Harnoss, Julian C.; Diener, Markus K.; Contin, Pietro; Ulrich, Alexis B.; Büchler, Markus W.; Schmitz-Winnenthal, Friedrich H.

    2014-01-01

    Abstract Portal annular pancreas (PAP) is an asymptomatic congenital pancreas anomaly, in which portal and/or mesenteric veins are encased by pancreas tissue. The aim of the study was to determine the role of PAP in pancreatic surgery as well as its management and potential complication, specifically, postoperative pancreatic fistula (POPF). On the basis of a case report, the MEDLINE and ISI Web of Science databases were systematically reviewed up to September 2012. All articles describing a case of PAP were considered. In summary, 21 studies with 59 cases were included. The overall prevalence of PAP was 2.4% and the patients' mean (SD) age was 55.9 (16.2) years. The POPF rate in patients with PAP (12 pancreaticoduodenectomies and 3 distal pancreatectomies) was 46.7% (in accordance with the definition of the International Study Group of Pancreatic Surgery). Portal annular pancreas is a quite unattended pancreatic variant with high prevalence and therefore still remains a clinical challenge to avoid postoperative complications. To decrease the risk for POPF, attentive preoperative diagnostics should also focus on PAP. In pancreaticoduodenectomy, a shift of the resection plane to the pancreas tail should be considered; in extensive pancreatectomy, coverage of the pancreatic remnant by the falciform ligament could be a treatment option. PMID:25207658

  2. Obliterative portal venopathy without portal hypertension: an underestimated condition.

    Science.gov (United States)

    Guido, Maria; Sarcognato, Samantha; Sonzogni, Aurelio; Lucà, Maria Grazia; Senzolo, Marco; Fagiuoli, Stefano; Ferrarese, Alberto; Pizzi, Marco; Giacomelli, Luciano; Colloredo, Guido

    2016-03-01

    Obliterative portal venopathy without portal hypertension has been described by a single study in a limited number of patients, thus very little is known about this clinical condition. This study aimed to investigate the prevalence of obliterative portal venopathy and its clinical-pathological correlations in patients with cryptogenic chronic liver test abnormalities without clinical signs of portal hypertension. We analysed 482 liver biopsies from adults with non-cirrhotic cryptogenic chronic liver disorders and without any clinical signs of portal hypertension, consecutively enrolled in a 5-year period. Twenty cases of idiopathic non-cirrhotic portal hypertension diagnosed in the same period, were included for comparison. Histological findings were matched with clinical and laboratory features. Obliterative portal venopathy was identified in 94 (19.5%) of 482 subjects and in all 20 cases of idiopathic non-cirrhotic portal hypertension: both groups shared the entire spectrum of histological changes described in the latter condition. The prevalence of incomplete fibrous septa and nodular regenerative hyperplasia was higher in the biopsies of idiopathic non-cirrhotic portal hypertension (P = 0.006 and P = 0.002), a possible hint of a more advanced stage of the disease. The two groups also shared several clinical laboratory features, including a similar liver function test profile, concomitant prothrombotic conditions and extrahepatic autoimmune disorders. Obliterative portal venopathy occurs in a substantial proportion of patients with unexplained chronic abnormal liver function tests without portal hypertension. The clinical-pathological profile of these subjects suggests that they may be in an early (non-symptomatic) stage of idiopathic non-cirrhotic portal hypertension. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin Fangfang; Gao Qinghuai; Xie Huchen; Nelson, Diana F.; Yu Yan; Kwok, W. Edmund; Totterman, Saara; Schell, Michael C.; Rubin, Philip

    1998-01-01

    Purpose: To investigate a method for the generation of digitally reconstructed radiographs directly from MR images (DRR-MRI) to guide a computerized portal verification procedure. Methods and Materials: Several major steps were developed to perform an MR image-guided portal verification procedure. Initially, a wavelet-based multiresolution adaptive thresholding method was used to segment the skin slice-by-slice in MR brain axial images. Some selected anatomical structures, such as target volume and critical organs, were then manually identified and were reassigned to relatively higher intensities. Interslice information was interpolated with a directional method to achieve comparable display resolution in three dimensions. Next, a ray-tracing method was used to generate a DRR-MRI image at the planned treatment position, and the ray tracing was simply performed on summation of voxels along the ray. The skin and its relative positions were also projected to the DRR-MRI and were used to guide the search of similar features in the portal image. A Canny edge detector was used to enhance the brain contour in both portal and simulation images. The skin in the brain portal image was then extracted using a knowledge-based searching technique. Finally, a Chamfer matching technique was used to correlate features between DRR-MRI and portal image. Results: The MR image-guided portal verification method was evaluated using a brain phantom case and a clinical patient case. Both DRR-CT and DRR-MRI were generated using CT and MR phantom images with the same beam orientation and then compared. The matching result indicated that the maximum deviation of internal structures was less than 1 mm. The segmented results for brain MR slice images indicated that a wavelet-based image segmentation technique provided a reasonable estimation for the brain skin. For the clinical patient case with a given portal field, the MR image-guided verification method provided an excellent match between

  4. SOFC/TEG hybrid mCHP system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    2012-03-15

    The starting point for this project have been the challenge has been to develop a cost effective solution with long term stability. This is where a focused effort in a strong consortium covering material research, module development and manufacture as well as device design and optimization can make a real difference. In March 2010 the SOFTEG phase II project was initiated and a cooperation organization was established to implement the project as a development and demonstration project involving the staff from all project partners. The project is now completed with excellent and documented outcome. The final results by Alpcon have been demonstration as a TEG-based mCHP system calls CHP Dual Engine Power System, which will be applicable as both a standalone TEG-CHP hybrid system, but also as an auxiliary power unit and power booster for the SOFC system. However the SOFC system cannot cover the household's heat demand alone so it is necessary to combine a SOFC system together with a water heater/boiler system to cover the peak heat demand of a residential house or a complex building. The SOFTEG project partners achieved significant results that mainly can be outlined as following: 1) University of Aarhus has improved the thermal stability of ZnSb by optimizing the concentration of Nano composite material. 2) The grain size and its influence on the sintering process by spark plasma method are investigated by Aarhus University, but further work seems to be necessary. 3) The TE material is going to commercialization by Aarhus University. 4) Aalborg University has prepared simulation tools for complex thermoelectric simulation in non-steady state condition. 5) The new type DCDC interleaved converter using the MPPT system for optimal power tracing is designed, build and tested by Aalborg University in cooperation with Alpcon. This task is included overall system design, control system implementation and power electronic control design. 6) Full scale practical

  5. The CEOS-Land Surface Imaging Constellation Portal for GEOSS: A resource for land surface imaging system information and data access

    Science.gov (United States)

    Holm, Thomas; Gallo, Kevin P.; Bailey, Bryan

    2010-01-01

    The Committee on Earth Observation Satellites is an international group that coordinates civil space-borne observations of the Earth, and provides the space component of the Global Earth Observing System of Systems (GEOSS). The CEOS Virtual Constellations concept was implemented in an effort to engage and coordinate disparate Earth observing programs of CEOS member agencies and ultimately facilitate their contribution in supplying the space-based observations required to satisfy the requirements of the GEOSS. The CEOS initially established Study Teams for four prototype constellations that included precipitation, land surface imaging, ocean surface topography, and atmospheric composition. The basic mission of the Land Surface Imaging (LSI) Constellation [1] is to promote the efficient, effective, and comprehensive collection, distribution, and application of space-acquired image data of the global land surface, especially to meet societal needs of the global population, such as those addressed by the nine Group on Earth Observations (GEO) Societal Benefit Areas (SBAs) of agriculture, biodiversity, climate, disasters, ecosystems, energy, health, water, and weather. The LSI Constellation Portal is the result of an effort to address important goals within the LSI Constellation mission and provide resources to assist in planning for future space missions that might further contribute to meeting those goals.

  6. Extrahepatic portal hypertension in childhood. Portographic findings and evaluation of hepatic blood flow by computerized radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-05-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood.

  7. Practical reliability and uncertainty quantification in complex systems : final report.

    Energy Technology Data Exchange (ETDEWEB)

    Grace, Matthew D.; Ringland, James T.; Marzouk, Youssef M. (Massachusetts Institute of Technology, Cambridge, MA); Boggs, Paul T.; Zurn, Rena M.; Diegert, Kathleen V. (Sandia National Laboratories, Albuquerque, NM); Pebay, Philippe Pierre; Red-Horse, John Robert (Sandia National Laboratories, Albuquerque, NM)

    2009-09-01

    The purpose of this project was to investigate the use of Bayesian methods for the estimation of the reliability of complex systems. The goals were to find methods for dealing with continuous data, rather than simple pass/fail data; to avoid assumptions of specific probability distributions, especially Gaussian, or normal, distributions; to compute not only an estimate of the reliability of the system, but also a measure of the confidence in that estimate; to develop procedures to address time-dependent or aging aspects in such systems, and to use these models and results to derive optimal testing strategies. The system is assumed to be a system of systems, i.e., a system with discrete components that are themselves systems. Furthermore, the system is 'engineered' in the sense that each node is designed to do something and that we have a mathematical description of that process. In the time-dependent case, the assumption is that we have a general, nonlinear, time-dependent function describing the process. The major results of the project are described in this report. In summary, we developed a sophisticated mathematical framework based on modern probability theory and Bayesian analysis. This framework encompasses all aspects of epistemic uncertainty and easily incorporates steady-state and time-dependent systems. Based on Markov chain, Monte Carlo methods, we devised a computational strategy for general probability density estimation in the steady-state case. This enabled us to compute a distribution of the reliability from which many questions, including confidence, could be addressed. We then extended this to the time domain and implemented procedures to estimate the reliability over time, including the use of the method to predict the reliability at a future time. Finally, we used certain aspects of Bayesian decision analysis to create a novel method for determining an optimal testing strategy, e.g., we can estimate the 'best' location to

  8. THE ROLE OF ENTERPRISE PORTALS IN ENTERPRISE INTEGRATION

    Directory of Open Access Journals (Sweden)

    Gianina RIZESCU

    2006-01-01

    Full Text Available Today’s enterprises are moving business systems to the Internet - to connect people, business processes, and people to business processes in enterprise and across enterprise boundaries. The portal brings it all together: business processes, departmental sites, knowledge management resources, enterprise management systems, CRM systems, analytics, email, calendars, external content, transactions,administration, workflow, and more. The goal of this paper is to present the role of the Enterprise Portal in internal and external enterprise integration.

  9. Knowledge Portals: Ontologies at Work

    OpenAIRE

    Staab, Steffen; Maedche, Alexander

    2001-01-01

    Knowledge portals provide views onto domain-specific information on the World Wide Web, thus helping their users find relevant, domain-specific information. The construction of intelligent access and the contribution of information to knowledge portals, however, remained an ad hoc task, requiring extensive manual editing and maintenance by the knowledge portal providers. To diminish these efforts, we use ontologies as a conceptual backbone for providing, accessing, and structuring information...

  10. TIPS Placement via Combined Transjugular and Transhepatic Approach for Cavernous Portal Vein Occlusion: Targeted Approach

    Directory of Open Access Journals (Sweden)

    Natanel Jourabchi

    2013-01-01

    Full Text Available Purpose. We report a novel technique which aided recanalization of an occluded portal vein for transjugular intrahepatic portosystemic shunt (TIPS creation in a patient with symptomatic portal vein thrombosis with cavernous transformation. Some have previously considered cavernous transformation a contraindication to TIPS. Case Presentation. 62-year-old man with chronic pancreatitis, portal vein thrombosis, portal hypertension and recurrent variceal bleeding presents with melena and hematemesis. The patient was severely anemic, hemodynamically unstable, and required emergent portal decompression. Attempts to recanalize the main portal vein using traditional transjugular access were unsuccessful. After percutaneous transhepatic right portal vein access and navigation of a wire through the occluded main portal vein, an angioplasty balloon was inflated at the desired site of shunt takeoff. The balloon was targeted and punctured from the transjugular approach, and a wire was passed into the portal system. TIPS placement then proceeded routinely. Conclusion. Although occlusion of the portal vein increases difficulty of performing TIPS, it should not be considered an absolute contraindication. We have described a method for recanalizing an occluded portal vein using a combined transhepatic and transjugular approach for TIPS. This approach may be useful to relieve portal hypertension in patients who fail endoscopic and/or surgical therapies.

  11. A neutron portal monitor for vehicles

    International Nuclear Information System (INIS)

    Coop, K.L.; Fehlau, P.E.; Atwater, H.F.

    1987-01-01

    We have designed and built a portal vehicle monitoring systems for detecting neutron-emitting special nuclear material (SNM) such as plutonium. Monte Carlo calculations were used to optimize the design of the 15-cm-deep x 122-cm-high x 244-cm-long detector chambers, which utilize 3 He proportional counters inside a hollow polyethylene box. Results for a variety of parametric studies, including polyethylene thickness and detector number, are described. Our experimental measurements are in good agreement with the computer calculations. The monitor's decision logic uses the Sequential Probability Ratio Test (SPRT) on Poisson distributed counting data, which is superior to other statistical tests in many applications. We performed computer simulations of the SPRT logic to determine expected false-positive decision rates. A controller unit of our design that uses this SPRT was built commercially. The cost of the complete monitoring system is similar to that of vehicle portal monitors that detect gamma rays. This new neutron monitor can serve as an addition to standard gamma-ray vehicle portals or as a stand-alone portal monitor in particular safeguards monitoring situations. The monitor is being tested at Los Alamos and is scheduled for in-plant evaluation of another DOE facility in 1987. 7 refs

  12. Urban Integrated Industrial Cogeneration Systems Analysis. Phase II final report

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    Through the Urban Integrated Industrial Cogeneration Systems Analysis (UIICSA), the City of Chicago embarked upon an ambitious effort to identify the measure the overall industrial cogeneration market in the city and to evaluate in detail the most promising market opportunities. This report discusses the background of the work completed during Phase II of the UIICSA and presents the results of economic feasibility studies conducted for three potential cogeneration sites in Chicago. Phase II focused on the feasibility of cogeneration at the three most promising sites: the Stockyards and Calumet industrial areas, and the Ford City commercial/industrial complex. Each feasibility case study considered the energy load requirements of the existing facilities at the site and the potential for attracting and serving new growth in the area. Alternative fuels and technologies, and ownership and financing options were also incorporated into the case studies. Finally, site specific considerations such as development incentives, zoning and building code restrictions and environmental requirements were investigated.

  13. Final design of thermal diagnostic system in SPIDER ion source

    Energy Technology Data Exchange (ETDEWEB)

    Brombin, M., E-mail: matteo.brombin@igi.cnr.it; Dalla Palma, M.; Pasqualotto, R.; Pomaro, N. [Consorzio RFX, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2016-11-15

    The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H{sup −} production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

  14. Final design of thermal diagnostic system in SPIDER ion source

    International Nuclear Information System (INIS)

    Brombin, M.; Dalla Palma, M.; Pasqualotto, R.; Pomaro, N.

    2016-01-01

    The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H"− production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

  15. Effects of medium-chain triglycerides, long-chain triglycerides, or 2-monododecanoin on fatty acid composition in the portal vein, intestinal lymph, and systemic circulation in rats.

    Science.gov (United States)

    You, Yi-Qian Nancy; Ling, Pei-Ra; Qu, Jason Zhensheng; Bistrian, Bruce R

    2008-01-01

    Fatty acid absorption patterns can have a major impact on the fatty acid composition in the portal, intestinal lymph, and systemic circulation. This study sought to determine the effects of long-chain triglycerides (LCT), medium-chain triglycerides (MCT), and 2-monododecanoin (2mono) on intestinal fatty acid composition during continuous feeding over a brief period. The lipid sources were 100% LCT, 100% MCT, a 50:50 mixture of LCT and MCT (LCT/MCT), and a 50:50 mixture of LCT and 2mono (LCT/2mono). A total of 27 rats were randomly given 1 of the 4 diets at 200 kcal/kg/d, with 30% of total calories from lipids over 3 hours. MCT significantly increased each of the medium-chain fatty acids (C6:0, C8:0, and C10:0) as free fatty acids in the portal vein and about 10%/mol of C10:0 as triglycerides in the lymph compared with the other groups. There was significantly less C10:0 in lymphatic triglycerides with LCT/MCT than with MCT, but more than in the LCT and LCT/2mono diets. MCT also significantly increased the contents of C16:0, C18:0, C18:1, and C20:4 in the lymphatic triglycerides compared with all other groups including LCT/MCT. The amount of linoleic acid (C18:2) in lymphatic triglycerides followed the relative amounts of this fatty acid in the diet, with the greatest in LCT followed by LCT/MCT and LCT/2mono and least in MCT. A so-called structured lipid composed of the medium-chain fatty acid dodecanoic acid on the 2 position and long-chain fatty acids on the 1 and 3 positions appeared to be endogenously synthesized in response to the LCT/2mono diet. The original differences in MCT and LCT content in the diets were preserved in the fatty acid composition in the intestinal free fatty acids and triglycerides during feeding. In addition, the duration of lipid administration can play a role in altering fatty acid composition in the intestine.

  16. Effects of Medium-Chain Triglycerides, Long-Chain Triglycerides, or 2-Monododecanoin on Fatty Acid Composition in the Portal Vein, Intestinal Lymph, and Systemic Circulation in Rats

    Science.gov (United States)

    Nancy You, Yi-Qian; Ling, Pei-Ra; Qu, Jason Zhensheng; Bistrian, Bruce R.

    2011-01-01

    Background Fatty acid absorption patterns can have a major impact on the fatty acid composition in the portal, intestinal lymph, and systemic circulation. This study sought to determine the effects of long-chain triglycerides (LCT), medium-chain triglycerides (MCT), and 2-monododecanoin (2mono) on intestinal fatty acid composition during continuous feeding over a brief period. Methods The lipid sources were 100% LCT, 100% MCT, a 50:50 mixture of LCT and MCT (LCT/MCT), and a 50:50 mixture of LCT and 2mono (LCT/2mono). A total of 27 rats were randomly given 1 of the 4 diets at 200 kcal/kg/d, with 30% of total calories from lipids over 3 hours. Results MCT significantly increased each of the medium-chain fatty acids (C6:0, C8:0, and C10:0) as free fatty acids in the portal vein and about 10%/mol of C10:0 as triglycerides in the lymph compared with the other groups. There was significantly less C10:0 in lymphatic triglycerides with LCT/MCT than with MCT, but more than in the LCT and LCT/2mono diets. MCT also significantly increased the contents of C16:0, C18:0, C18:1, and C20:4 in the lymphatic triglycerides compared with all other groups including LCT/MCT. The amount of linoleic acid (C18:2) in lymphatic triglycerides followed the relative amounts of this fatty acid in the diet, with the greatest in LCT followed by LCT/MCT and LCT/2mono and least in MCT. A so-called structured lipid composed of the medium-chain fatty acid dodecanoic acid on the 2 position and long-chain fatty acids on the 1 and 3 positions appeared to be endogenously synthesized in response to the LCT/2mono diet. Conclusions The original differences in MCT and LCT content in the diets were preserved in the fatty acid composition in the intestinal free fatty acids and triglycerides during feeding. In addition, the duration of lipid administration can play a role in altering fatty acid composition in the intestine. PMID:18407910

  17. Duplex sonography in portal hypertension

    International Nuclear Information System (INIS)

    Kwon, Hyuk Po; Jang, J. C.; Park, B. H.

    1990-01-01

    We measure the diameter and blood velocity of the portal vein in 50 patients with cirrhosis of the liver and 40 healthy subjects, and calculated cross sectional area, mean blood flow velocity, blood flow volume and congestion index. In patients with cirrhosis of the liver, the cross sectional area of the portal vein was significantly increased: the mean blood flow volume was significantly reduced; the blood flow volume was significantly increased; the congestion index of the portal vein was significantly increased. Duples sonography may play an important role in the diagnosis of portal hypertension

  18. Transcatheter arterial chemoembolization of hepatocellular carcinoma with portal vein invasion

    International Nuclear Information System (INIS)

    Lee, Young Rahn; Lee, Ki Yeol; Cho, Seong Beom; Cha, In Ho; Chung, Kyoo Byung

    1993-01-01

    Transcatheter arterial chemoembolization(TACE) is an imperative method for the management of inoperable hepatocellular carcinoma(HCC). It is well known that primary HCC frequently invades the portal venous system and forms a tumor thrombus obstructing the portal blood flow which makes unfavorable prognosis of patient. We retrospectively reviewed 58 patients who reviewed TACE(minimum 3 times) of HCC invading into portal venous system. Group 1(n=29) which showed peripheral portal vein invasion had better clinical and laboratory response. Group 2(n=17) which showed first order portal branch invasion had similar response to Group 3(n=12), which had main portal invasion. Group 1 showed no difference in survival time between TAC and TACE, but, in Group 2 and 3, embolization with chemotherapy made longer survival than chemotherapy only. Clinical level of AFP was meaningful in Group 1 and 2 as decreasing value. Our results provides that careful selection of TAE and case by case Coil/Gelfoam embolization can improve the mean survival and clinical response when HCC evidently invades portal venous system

  19. State of the SOOS GCMD Portal

    Science.gov (United States)

    Ritz, Scott

    2018-01-01

    A brief status update on NASA’s latest Global Change Master Directory (GCMD) keyword update, description of the differences between DIF-9 and DIF-10 formats in advance of the deprecation of DIF-9 support in Earth Observing System Data and Information System (EOSDIS) with specifics on the DIF-10.3 schema, transition schedule, and some usage metrics for the GCMD Southern Ocean Observing System (SOOS) Portal.

  20. PSUP: A Planetary SUrface Portal

    Science.gov (United States)

    Poulet, F.; Quantin-Nataf, C.; Ballans, H.; Dassas, K.; Audouard, J.; Carter, J.; Gondet, B.; Lozac'h, L.; Malapert, J.-C.; Marmo, C.; Riu, L.; Séjourné, A.

    2018-01-01

    The large size and complexity of planetary data acquired by spacecraft during the last two decades create a demand within the planetary community for access to the archives of raw and high level data and for the tools necessary to analyze these data. Among the different targets of the Solar System, Mars is unique as the combined datasets from the Viking, Mars Global Surveyor, Mars Odyssey, Mars Express and Mars Reconnaissance Orbiter missions provide a tremendous wealth of information that can be used to study the surface of Mars. The number and the size of the datasets require an information system to process, manage and distribute data. The Observatories of Paris Sud (OSUPS) and Lyon (OSUL) have developed a portal, called PSUP (Planetary SUrface Portal), for providing users with efficient and easy access to data products dedicated to the Martian surface. The objectives of the portal are: 1) to allow processing and downloading of data via a specific application called MarsSI (Martian surface data processing Information System); 2) to provide the visualization and merging of high level (image, spectral, and topographic) products and catalogs via a web-based user interface (MarsVisu), and 3) to distribute some of these specific high level data with an emphasis on products issued by the science teams of OSUPS and OSUL. As the MarsSI service is extensively described in a companion paper (Quantin-Nataf et al., companion paper, submitted to this special issue), the present paper focus on the general architecture and the functionalities of the web-based user interface MarsVisu. This service provides access to many data products for Mars: albedo, mineral and thermal inertia global maps from spectrometers; mosaics from imagers; image footprints and rasters from the MarsSI tool; high level specific products (defined as catalogs or vectors). MarsVisu can be used to quickly assess the visualized processed data and maps as well as identify areas that have not been mapped yet

  1. Acoustic Resonance Spectroscopy (ARS) Munition Classification System enhancements. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Vela, O.A.; Huggard, J.C.

    1997-09-18

    Acoustic Resonance Spectroscopy (ARS) is a non-destructive evaluation technology developed at the Los Alamos National Laboratory (LANL). This technology has resulted in three generations of instrumentation, funded by the Defense Special Weapons Agency (DSWA), specifically designed for field identification of chemical weapon (CW) munitions. Each generation of ARS instrumentation was developed with a specific user in mind. The ARS1OO was built for use by the U.N. Inspection Teams going into Iraq immediately after the Persian Gulf War. The ARS200 was built for use in the US-Russia Bilateral Chemical Weapons Treaty (the primary users for this system are the US Onsite Inspection Agency (OSIA) and their Russian counterparts). The ARS300 was built with the requirements of the Organization for the Prohibition of Chemical Weapons (OPCW) in mind. Each successive system is an improved version of the previous system based on learning the weaknesses of each and, coincidentally, on the fact that more time was available to do a requirements analysis and the necessary engineering development. The ARS300 is at a level of development that warrants transferring the technology to a commercial vendor. Since LANL will supply the computer software to the selected vendor, it is possible for LANL to continue to improve the decision algorithms, add features where necessary, and adjust the user interface before the final transfer occurs. This paper describes the current system, ARS system enhancements, and software enhancements. Appendices contain the Operations Manual (software Version 3.01), and two earlier reports on enhancements.

  2. Lactitol, a second-generation disaccharide for treatment of chronic portal-systemic encephalopathy. A double-blind, crossover, randomized clinical trial.

    Science.gov (United States)

    Uribe, M; Toledo, H; Perez, F; Vargas, F; Gil, S; Garcia-Ramos, G; Ravelli, G P; Guevara, L

    1987-12-01

    A double-blind crossover trial was performed to test the therapeutic usefulness and safety of lactitol, a beta-galactoside sorbitol, against lactose in 18 patients with chronic portal-systemic encephalopathy (PSE). The study included four periods: two for washout and two for lactitol and lactose administration. During washout periods, which lasted two weeks each, patients were stabilized with neomycin plus milk of magnesia. Lactitol and lactose were administered during four weeks each. Ten patients were randomly assigned to receive lactose (group A) and eight patients to receive lactitol (group B) first. PSE parameters, ie, mental state, number connection test performance, asterixis and blood ammonia levels were assessed fortnightly. Electroencephalographic tracings and stool pHs were evaluated at the end of each study period. After the first administration of lactose and lactitol, no statistically significant differences in PSE parameters were found. At the same stage, a significant stool acidification (P less than 0.05) was detected. It is concluded that lactitol seems to be safe and efficacious in treating patients with chronic PSE.

  3. Commercial thermal distribution systems, Final report for CIEE/CEC

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Tengfang; Bechu, Olivier; Carrie, Remi; Dickerhoff, Darryl; Fisk, William; Franconi, Ellen; Kristiansen, Oyvind; Levinson, Ronnen; McWilliams, Jennifer; Wang, Duo; Modera, Mark; Webster, Tom; Ring, Erik; Zhang, Qiang; Huizenga, Charlie; Bauman, Fred; Arens, Ed

    1999-12-01

    According to the California Energy Commission (CEC 1998a), California commercial buildings account for 35% of statewide electricity consumption, and 16% of statewide gas consumption. Space conditioning accounts for roughly 16,000 GWh of electricity and 800 million therms of natural gas annually, and the vast majority of this space conditioning energy passes through thermal distribution systems in these buildings. In addition, 8600 GWh per year is consumed by fans and pumps in commercial buildings, most of which is used to move the thermal energy through these systems. Research work at Lawrence Berkeley National Laboratory (LBNL) has been ongoing over the past five years to investigate the energy efficiency of these thermal distribution systems, and to explore possibilities for improving that energy efficiency. Based upon that work, annual savings estimates of 1 kWh/ft{sup 2} for light commercial buildings, and 1-2 kWh/ft{sup 2} in large commercial buildings have been developed for the particular aspects of thermal distribution system performance being addressed by this project. Those savings estimates, combined with a distribution of the building stock based upon an extensive stock characterization study (Modera et al. 1999a), and technical penetration estimates, translate into statewide saving potentials of 2000 GWh/year and 75 million thermal/year, as well as an electricity peak reduction potential of 0.7 GW. The overall goal of this research program is to provide new technology and application knowledge that will allow the design, construction, and energy services industries to reduce the energy waste associated with thermal distribution systems in California commercial buildings. The specific goals of the LBNL efforts over the past year were: (1) to advance the state of knowledge about system performance and energy losses in commercial-building thermal distribution systems; (2) to evaluate the potential of reducing thermal losses through duct sealing, duct

  4. MO-FG-202-04: Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device

    Energy Technology Data Exchange (ETDEWEB)

    Zwan, B J [Central Coast Cancer Centre, Gosford, NSW (Australia); University of Newcastle, Newcastle, NSW (Australia); Barnes, M; Greer, P B [University of Newcastle, Newcastle, NSW (Australia); Calvary Mater Hospital, Newcastle, NSW (Australia); Hindmarsh, J; Seymour, E [Central Coast Cancer Centre, Gosford, NSW (Australia); O’Connor, D J [University of Newcastle, Newcastle, NSW (Australia); Keall, P J [University of Sydney, Camperdown, NSW (Australia)

    2016-06-15

    Purpose: To automate gantry-resolved linear accelerator (linac) quality assurance (QA) for volumetric modulated arc therapy (VMAT) using an electronic portal imaging device (EPID). Methods: A QA system for VMAT was developed that uses an EPID, frame-grabber assembly and in-house developed image processing software. The system relies solely on the analysis of EPID image frames acquired without the presence of a phantom. Images were acquired at 8.41 frames per second using a frame grabber and ancillary acquisition computer. Each image frame was tagged with a gantry angle from the linac’s on-board gantry angle encoder. Arc-dynamic QA plans were designed to assess the performance of each individual linac component during VMAT. By analysing each image frame acquired during the QA deliveries the following eight machine performance characteristics were measured as a function of gantry angle: MLC positional accuracy, MLC speed constancy, MLC acceleration constancy, MLC-gantry synchronisation, beam profile constancy, dose rate constancy, gantry speed constancy, dose-gantry angle synchronisation and mechanical sag. All tests were performed on a Varian iX linear accelerator equipped with a 120 leaf Millennium MLC and an aS1000 EPID (Varian Medical Systems, Palo Alto, CA, USA). Results: Machine performance parameters were measured as a function of gantry angle using EPID imaging and compared to machine log files and the treatment plan. Data acquisition is currently underway at 3 centres, incorporating 7 treatment units, at 2 weekly measurement intervals. Conclusion: The proposed system can be applied for streamlined linac QA and commissioning for VMAT. The set of test plans developed can be used to assess the performance of each individual components of the treatment machine during VMAT deliveries as a function of gantry angle. The methodology does not require the setup of any additional phantom or measurement equipment and the analysis is fully automated to allow for

  5. MO-FG-202-04: Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Zwan, B J; Barnes, M; Greer, P B; Hindmarsh, J; Seymour, E; O’Connor, D J; Keall, P J

    2016-01-01

    Purpose: To automate gantry-resolved linear accelerator (linac) quality assurance (QA) for volumetric modulated arc therapy (VMAT) using an electronic portal imaging device (EPID). Methods: A QA system for VMAT was developed that uses an EPID, frame-grabber assembly and in-house developed image processing software. The system relies solely on the analysis of EPID image frames acquired without the presence of a phantom. Images were acquired at 8.41 frames per second using a frame grabber and ancillary acquisition computer. Each image frame was tagged with a gantry angle from the linac’s on-board gantry angle encoder. Arc-dynamic QA plans were designed to assess the performance of each individual linac component during VMAT. By analysing each image frame acquired during the QA deliveries the following eight machine performance characteristics were measured as a function of gantry angle: MLC positional accuracy, MLC speed constancy, MLC acceleration constancy, MLC-gantry synchronisation, beam profile constancy, dose rate constancy, gantry speed constancy, dose-gantry angle synchronisation and mechanical sag. All tests were performed on a Varian iX linear accelerator equipped with a 120 leaf Millennium MLC and an aS1000 EPID (Varian Medical Systems, Palo Alto, CA, USA). Results: Machine performance parameters were measured as a function of gantry angle using EPID imaging and compared to machine log files and the treatment plan. Data acquisition is currently underway at 3 centres, incorporating 7 treatment units, at 2 weekly measurement intervals. Conclusion: The proposed system can be applied for streamlined linac QA and commissioning for VMAT. The set of test plans developed can be used to assess the performance of each individual components of the treatment machine during VMAT deliveries as a function of gantry angle. The methodology does not require the setup of any additional phantom or measurement equipment and the analysis is fully automated to allow for

  6. Endothelial dysfunction in the regulation of portal hypertension

    Science.gov (United States)

    Iwakiri, Yasuko

    2013-01-01

    Portal hypertension is caused by an increased intrahepatic resistance, a major consequence of cirrhosis. Endothelial dysfunction in liver sinusoidal endothelial cells (LSECs) decreases the production of vasodilators, such as nitric oxide (NO) and favors vasoconstriction. This contributes to an increased vascular resistance in the intrahepatic/sinusoidal microcirculation. Portal hypertension, once developed, causes endothelial cell (EC) dysfunction in the extrahepatic, i.e. splanchnic and systemic, circulation. Unlike LSEC dysfunction, EC dysfunction in the splanchnic and systemic circulation overproduces vasodilator molecules, leading to arterial vasodilatation. In addition, portal hypertension leads to the formation of portosystemic collateral vessels. Both arterial vasodilatation and portosystemic collateral vessel formation exacerbate portal hypertension by increasing the blood flow through the portal vein. Pathologic consequences, such as esophageal varices and ascites, result. While the sequence of pathological vascular events in cirrhosis and portal hypertension have been elucidated, the underlying cellular and molecular mechanisms causing EC dysfunctions are not yet fully understood. This review article summarizes the current cellular and molecular studies on EC dysfunctions found during the development of cirrhosis and portal hypertension with a focus on intra- and extrahepatic circulation. The article ends by discussing future directions of study for EC dysfunctions. PMID:21745318

  7. Electron beam final focus system for Thomson scattering at ELBE

    Energy Technology Data Exchange (ETDEWEB)

    Krämer, J.M., E-mail: jmkr@danfysik.dk [Danfysik A/S, Gregersensvej 8, 2630 Taastrup (Denmark); Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstrasse 400, 01328 Dresden (Germany); Technische Universität Dresden, 01069 Dresden (Germany); Budde, M.; Bødker, F. [Danfysik A/S, Gregersensvej 8, 2630 Taastrup (Denmark); Irman, A.; Jochmann, A. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstrasse 400, 01328 Dresden (Germany); Kristensen, J.P. [Danfysik A/S, Gregersensvej 8, 2630 Taastrup (Denmark); Lehnert, U.; Michel, P. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstrasse 400, 01328 Dresden (Germany); Schramm, U. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstrasse 400, 01328 Dresden (Germany); Technische Universität Dresden, 01069 Dresden (Germany)

    2016-09-11

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and divergences of about 10 mrad using the FFS.

  8. Electron beam final focus system for Thomson scattering at ELBE

    CERN Document Server

    Krämer, J.M.; Bødker, F.; Irman, A.; .Jochmann A.; Kristensen, J.P.; Lehnert U., HZDR; Michel, P.; Schrammb, U.; 10.1016/j.nima.2015.10.067

    2016-01-01

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and diverg...

  9. Electron Beam Final Focus System For Thomson Scattering At Elbe

    CERN Document Server

    Krämer, J.M.; Bødkera, F.; Irman, A.; Jochmann, A.; Kristensena, J.P.; Lehnert, U.; Michel, P.; Schramm, U.; 10.1016/j.nima.2015.10.067

    2016-01-01

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and diverg...

  10. Foundations for Improvements to Passive Detection Systems - Final Report

    International Nuclear Information System (INIS)

    Labov, S E; Pleasance, L; Sokkappa, P; Craig, W; Chapline, G; Frank, M; Gronberg, J; Jernigan, J G; Johnson, S; Kammeraad, J; Lange, D; Meyer, A; Nelson, K; Pohl, B; Wright, D; Wurtz, R

    2004-01-01

    This project explores the scientific foundation and approach for improving passive detection systems for plutonium and highly enriched uranium in real applications. Sources of gamma-ray radiation of interest were chosen to represent a range of national security threats, naturally occurring radioactive materials, industrial and medical radiation sources, and natural background radiation. The gamma-ray flux emerging from these sources, which include unclassified criticality experiment configurations as surrogates for nuclear weapons, were modeled in detail. The performance of several types of gamma-ray imaging systems using Compton scattering were modeled and compared. A mechanism was created to model the combine sources and background emissions and have the simulated radiation ''scene'' impinge on a model of a detector. These modeling tools are now being used in various projects to optimize detector performance and model detector sensitivity in complex measuring environments. This study also developed several automated algorithms for isotope identification from gamma-ray spectra and compared these to each other and to algorithms already in use. Verification testing indicates that these alternative isotope identification algorithms produced less false positive and false negative results than the ''GADRAS'' algorithms currently in use. In addition to these algorithms that used binned spectra, a new approach to isotope identification using ''event mode'' analysis was developed. Finally, a technique using muons to detect nuclear material was explored

  11. Final focus system tuning studies towards Compact Linear Collider feasibility

    Science.gov (United States)

    Marin, E.; Latina, A.; Tomás, R.; Schulte, D.

    2018-01-01

    In this paper we present the latest results regarding the tuning study of the baseline design of the final focus system of the Compact Linear Collider (CLIC-FFS). CLIC aims to provide collisions to the experiments at a luminosity above 1034 c m-2 s-1 . In order to deliver such luminosity in a single pass machine, the vertical beam size at the interaction point (IP) is reduced to about 1 nm, which imposes unprecedented tuning difficulties to the system. In previous studies, 90% of the machines reached 90% of the nominal luminosity at the expense of 18 000 luminosity measurements, when considering beam position monitor errors and transverse misalignments of magnets for a single beam case. In the present study, additional static imperfections as, roll misalignments, strength v2.epss are included. Moreover both e- and e+ beamlines are properly simulated. A new tuning procedure based on linear and nonlinear knobs is implemented to effectively cure the most relevant beam size aberrations at the IP. The obtained results for single and double beam studies under solely static imperfections are presented.

  12. Physics Experiments at the UNEDLabs Portal

    Directory of Open Access Journals (Sweden)

    Juan pedro Sánchez

    2012-01-01

    Full Text Available UNEDLabs is a web portal based on a free, modern, open source, and well-known learning management system: Moodle. This portal joins two theme networks of virtual and remote laboratories (one for Control Engineering and another one for Physics, named AutomatL@bs and FisL@bs, respectively together. AutomatL@bs has been operative for five years now. Following AutomatL@bs’ scheme, FisL@bs was created as a network of remote and virtual laboratories for physics university education via the Internet to offer students the possibility of performing hands-on experiences in different fields of physics in two ways: simulation and real remote operation. Now, both FisL@bs and AutomatL@bs join together (while maintaining their independency into an unique new web portal called UNEDLabs. This work focuses on this new web environment and gives a detailed account of a novel way in Physics to let distance learning students gain practical experience autonomously. This paper explains how the new portal works and the software tools used for creating it. In addition, it also describes the physics experiments which are already operative.

  13. Dissemination of Continuing Education Materials Via Television Delivery Systems. Final Technical Report and Final Report.

    Science.gov (United States)

    Munushian, Jack

    In 1972, the University of Southern California School of Engineering established a 4-channel interactive instructional television network. It was designed to allow employees of participating industries to take regular university science and engineering courses and special continuing education courses at or near their work locations. Final progress…

  14. Expanded studies of linear collider final focus systems at the Final Focus Test Beam

    International Nuclear Information System (INIS)

    Tenenbaum, P.G.

    1995-12-01

    In order to meet their luminosity goals, linear colliders operating in the center-of-mass energy range from 3,50 to 1,500 GeV will need to deliver beams which are as small as a few Manometers tall, with x:y aspect ratios as large as 100. The Final Focus Test Beam (FFTB) is a prototype for the final focus demanded by these colliders: its purpose is to provide demagnification equivalent to those in the future linear collider, which corresponds to a focused spot size in the FFTB of 1.7 microns (horizontal) by 60 manometers (vertical). In order to achieve the desired spot sizes, the FFTB beam optics must be tuned to eliminate aberrations and other errors, and to ensure that the optics conform to the desired final conditions and the measured initial conditions of the beam. Using a combination of incoming-beam diagnostics. beam-based local diagnostics, and global tuning algorithms, the FFTB beam size has been reduced to a stable final size of 1.7 microns by 70 manometers. In addition, the chromatic properties of the FFTB have been studied using two techniques and found to be acceptable. Descriptions of the hardware and techniques used in these studies are presented, along with results and suggestions for future research

  15. Expanded studies of linear collider final focus systems at the Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Tenenbaum, Peter Gregory [Stanford Univ., CA (United States)

    1995-12-01

    In order to meet their luminosity goals, linear colliders operating in the center-of-mass energy range from 3,50 to 1,500 GeV will need to deliver beams which are as small as a few Manometers tall, with x:y aspect ratios as large as 100. The Final Focus Test Beam (FFTB) is a prototype for the final focus demanded by these colliders: its purpose is to provide demagnification equivalent to those in the future linear collider, which corresponds to a focused spot size in the FFTB of 1.7 microns (horizontal) by 60 manometers (vertical). In order to achieve the desired spot sizes, the FFTB beam optics must be tuned to eliminate aberrations and other errors, and to ensure that the optics conform to the desired final conditions and the measured initial conditions of the beam. Using a combination of incoming-beam diagnostics. beam-based local diagnostics, and global tuning algorithms, the FFTB beam size has been reduced to a stable final size of 1.7 microns by 70 manometers. In addition, the chromatic properties of the FFTB have been studied using two techniques and found to be acceptable. Descriptions of the hardware and techniques used in these studies are presented, along with results and suggestions for future research.

  16. Development of a computerized portal verification scheme for pelvic treatment fields

    International Nuclear Information System (INIS)

    Nie, K.; Yin, F.-F.; Gao, Q.; Brasacchio, R.

    1996-01-01

    Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied to identify the field edges and an elliptic Fourier transformation is used to correlate the size and shape information between the reference and portal field edges. Several measures can be calculated using the transformation coefficients to describe the field shape, size and orientation. The quantitative information regarding to the relative shifts, rotation and magnification factor between portal and reference field edges can then be determined based on these measures. Next the pelvic brim, which is typically used as the landmark for radiation treatment verification, is identified by a pyramid searching process with double snakes defined from initial global area to final local area. A snake is an active model and energy-minimizing spline guided by external constraint forces and influenced by image forces that pull it toward features such as lines and edges. The search range is limited to the region between two snakes. Sobel edge detector and wavelet transformation approach are used to generate a serial image forces at

  17. Polyphenol-Rich Blackcurrant Juice Prevents Endothelial Dysfunction in the Mesenteric Artery of Cirrhotic Rats with Portal Hypertension: Role of Oxidative Stress and the Angiotensin System.

    Science.gov (United States)

    Rashid, Sherzad; Idris-Khodja, Noureddine; Auger, Cyril; Kevers, Claire; Pincemail, Joël; Alhosin, Mahmoud; Boehm, Nelly; Oswald-Mammosser, Monique; Schini-Kerth, Valérie B

    2018-04-01

    Chronic liver diseases with portal hypertension are characterized by a progressive vasodilatation, endothelial dysfunction, and NADPH oxidase-derived vascular oxidative stress, which have been suggested to involve the angiotensin system. This study evaluated the possibility that oral intake of polyphenol-rich blackcurrant juice (PRBJ), a rich natural source of antioxidants, prevents endothelial dysfunction in a rat model of cirrhosis induced by chronic bile duct ligation (CBDL), and, if so, determined the underlying mechanism. Male Wistar rats received either control drinking water or water containing 60 mg/kg gallic acid equivalents of PRBJ for 3 weeks before undergoing surgery with CBDL or sham surgery. After 4 weeks, vascular reactivity was assessed in mesenteric artery rings using organ chambers. Both the acetylcholine-induced nitric oxide (NO)- and endothelium-dependent hyperpolarization (EDH)-mediated relaxations in mesenteric artery rings were significantly reduced in CBDL rats compared to sham rats. An increased level of oxidative stress and expression of NADPH oxidase subunits, COX-2, NOS, and of the vascular angiotensin system are observed in arterial sections in the CBDL group. Chronic intake of PRBJ prevented the CBDL-induced impaired EDH-mediated relaxation, oxidative stress, and expression of the different target proteins in the arterial wall. In addition, PRBJ prevented the CBDL-induced increase in the plasma level of proinflammatory cytokines (interleukin [IL]-1α, monocyte chemotactic protein 1, and tumor necrosis factor α) and the decrease of the anti-inflammatory cytokine, IL-4. Altogether, these observations indicate that regular ingestion of PRBJ prevents the CBDL-induced endothelial dysfunction in the mesenteric artery most likely by normalizing the level of vascular oxidative stress and the angiotensin system.

  18. Lunar and Vesta Web Portals

    Science.gov (United States)

    Law, E.; JPL Luna Mapping; Modeling Project Team

    2015-06-01

    The Lunar Mapping and Modeling Project offers Lunar Mapping and Modeling Portal (http://lmmp.nasa.gov) and Vesta Trek Portal (http://vestatrek.jpl.nasa.gov) providing interactive visualization and analysis tools to enable users to access mapped Lunar and Vesta data products.

  19. Portal dosimetry in wedged beams

    NARCIS (Netherlands)

    Spreeuw, Hanno; Rozendaal, Roel; Camargo, Priscilla; Mans, Anton; Wendling, Markus; Olaciregui-Ruiz, Igor; Sonke, Jan-Jakob; van Herk, Marcel; Mijnheer, Ben

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the

  20. Clinical Trial Electronic Portals for Expedited Safety Reporting: Recommendations from the Clinical Trials Transformation Initiative Investigational New Drug Safety Advancement Project.

    Science.gov (United States)

    Perez, Raymond P; Finnigan, Shanda; Patel, Krupa; Whitney, Shanell; Forrest, Annemarie

    2016-12-15

    Use of electronic clinical trial portals has increased in recent years to assist with sponsor-investigator communication, safety reporting, and clinical trial management. Electronic portals can help reduce time and costs associated with processing paperwork and add security measures; however, there is a lack of information on clinical trial investigative staff's perceived challenges and benefits of using portals. The Clinical Trials Transformation Initiative (CTTI) sought to (1) identify challenges to investigator receipt and management of investigational new drug (IND) safety reports at oncologic investigative sites and coordinating centers and (2) facilitate adoption of best practices for communicating and managing IND safety reports using electronic portals. CTTI, a public-private partnership to improve the conduct of clinical trials, distributed surveys and conducted interviews in an opinion-gathering effort to record investigator and research staff views on electronic portals in the context of the new safety reporting requirements described in the US Food and Drug Administration's final rule (Code of Federal Regulations Title 21 Section 312). The project focused on receipt, management, and review of safety reports as opposed to the reporting of adverse events. The top challenge investigators and staff identified in using individual sponsor portals was remembering several complex individual passwords to access each site. Also, certain tasks are time-consuming (eg, downloading reports) due to slow sites or difficulties associated with particular operating systems or software. To improve user experiences, respondents suggested that portals function independently of browsers and operating systems, have intuitive interfaces with easy navigation, and incorporate additional features that would allow users to filter, search, and batch safety reports. Results indicate that an ideal system for sharing expedited IND safety information is through a central portal used by

  1. Health literacy and patient portals.

    Science.gov (United States)

    Gu, Yulong; Orr, Martin; Warren, Jim

    2015-06-01

    Health literacy has been described as the capacity to obtain, process, and understand basic health information and services needed to make appropriate health decisions. Improving health literacy may serve to promote concordance with therapy, engage patients in their own health care, and improve health outcomes. Patient portal technology aims at enabling patients and families to have easy access to key information in their own medical records and to communicate with their health care providers electronically. However, there is a gap in our understanding of how portals will improve patient outcome. The authors believe patient portal technology presents an opportunity to improve patient concordance with prescribed therapy, if adequate support is provided to equip patients (and family/carers) with the knowledge needed to utilise the health information available via the portals. Research is needed to understand what a health consumer will use patient portals for and how to support a user to realise the technology's potential.

  2. Portal monitoring for detecting fissile materials and chemical explosives

    International Nuclear Information System (INIS)

    Albright, D.

    1992-01-01

    The portal monitoring of pedestrians, packages, equipment, and vehicles entering or leaving areas of high physical security has been common for many years. Many nuclear facilities rely on portal monitoring to prevent the theft or diversion of plutonium and highly enriched uranium. At commercial airports, portals are used to prevent firearms and explosives from being smuggled onto airplanes. An August 1989 Federal Aviation Administration (FAA) regulation requires US airlines to screen luggage on international flights for chemical explosives. This paper reports that portal monitoring is now being introduced into arms-control agreements. Because some of the portal-monitoring equipment that would be useful in verifying arms-control agreements is already widely used as part of the physical security systems at nuclear facilities and commercial airports, the authors review these uses of portal monitoring, as well as its role in verifying the INF treaty. Then the authors survey the major types of portal-monitoring equipment that would be most useful in detecting nuclear warheads or fissile material

  3. The portal vein in children: radiological review of congenital anomalies and acquired abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Corness, Jonathan A.G.; McHugh, Kieran; Roebuck, Derek J. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Taylor, Andrew M. [Institute of Child Health, Cardiothoracic Unit, London (United Kingdom)

    2006-02-01

    A variety of portal vein anomalies that occur in children can be identified by US, CT, MRI and portal venography. Although these abnormalities can also occur in adults, there are certain pathological processes and aberrations within the portal system that are specific to children. Knowledge of the embryology and anatomy of the portal vein is of benefit in the understanding of these anomalies. Identifying deviations from normal portal architecture is important in the work-up for surgery such as liver transplantation, and prior to interventional procedures such as stent placement or embolization. The aim of this paper is to summarize the various types of congenital and acquired portal vein abnormalities that occur in children, describe their radiological features and provide images to demonstrate the differences from normal portal venous anatomy. (orig.)

  4. The portal vein in children: radiological review of congenital anomalies and acquired abnormalities

    International Nuclear Information System (INIS)

    Corness, Jonathan A.G.; McHugh, Kieran; Roebuck, Derek J.; Taylor, Andrew M.

    2006-01-01

    A variety of portal vein anomalies that occur in children can be identified by US, CT, MRI and portal venography. Although these abnormalities can also occur in adults, there are certain pathological processes and aberrations within the portal system that are specific to children. Knowledge of the embryology and anatomy of the portal vein is of benefit in the understanding of these anomalies. Identifying deviations from normal portal architecture is important in the work-up for surgery such as liver transplantation, and prior to interventional procedures such as stent placement or embolization. The aim of this paper is to summarize the various types of congenital and acquired portal vein abnormalities that occur in children, describe their radiological features and provide images to demonstrate the differences from normal portal venous anatomy. (orig.)

  5. Astronaut Neil A. Armstrong Undergoes Communications Systems Final Check

    Science.gov (United States)

    1969-01-01

    Dunned in his space suit, mission commander Neil A. Armstrong does a final check of his communications system before before the boarding of the Apollo 11 mission. Launched via a Saturn V launch vehicle, the first manned lunar mission launched from the Kennedy Space Center, Florida on July 16, 1969 and safely returned to Earth on July 24, 1969. The Saturn V vehicle was developed by the Marshall Space Flight Center (MSFC) under the direction of Dr. Wernher von Braun. The 3-man crew aboard the flight consisted of astronauts Armstrong; Michael Collins, Command Module (CM) pilot; and Edwin E. Aldrin, Jr., Lunar Module (LM) Pilot. Armstrong was the first human to ever stand on the lunar surface, followed by Edwin (Buzz) Aldrin. Meanwhile, astronaut Collins piloted the CM in a parking orbit around the Moon. During a 2½ hour surface exploration, the crew collected 47 pounds of lunar surface material which was returned to Earth for analysis. With the success of Apollo 11, the national objective to land men on the Moon and return them safely to Earth had been accomplished.

  6. User Experience Design in Professional Map-Based Geo-Portals

    Directory of Open Access Journals (Sweden)

    Bastian Zimmer

    2013-10-01

    Full Text Available We have recently been witnessing the growing establishment of map-centered web-based geo-portals on national, regional and local levels. However, a particular issue with these geo-portals is that each instance has been implemented in different ways in terms of design, usability, functionality, interaction possibilities, map size and symbologies. In this paper, we try to tackle these shortcomings by analyzing and formalizing the requirements for map-based geo-portals in a user experience based approach. First, we propose a holistic definition the term of a “geo-portal”. Then, we present our approach to user experience design for map-based geo-portals by defining the functional requirements of a geo-portal, by analyzing previous geo-portal developments, by distilling the results of our empirical user study to perform practically-oriented user requirements, and finally by establishing a set of user experience design guidelines for the creation of map-based geo-portals. These design guidelines have been extracted for each of the main components of a geo-portal, i.e., the map, the search dialogue, the presentation of the search results, symbologies, and other aspects. These guidelines shall constitute the basis for future geo-portal developments to achieve standardization in the user-experience design of map-based geo-portals.

  7. GENIUS/EnginFrame Grid Portal: VOMS Proxy creation, new features and enhancements

    International Nuclear Information System (INIS)

    Ardizzone, V.; Barbaram, R.; Falzone, A.; Emidio, G.; Neri, L.; Scardaci, D.; Venuti, N.

    2007-01-01

    Scientific domain knowledge and tools must be presented to the (non-expert) users in terms of applications without needing to know the underlying details of the Grid Middle wares. GENIUS Grid portal, powered by EnginFrame, is an increasingly popular mechanism for creating customisable, Web-based interfaces to Grid services and resources. This work describes new GENIUS portals capabilities such as portal login, access control, display management, new approach to building reusable portal components as plug ins, better performance results as consequence of EnginFrame core functions improvement. Finally will be described two new tools developed for VOMS Proxy creation and simple JDL composer. (Author)

  8. GENIUS/EnginFrame Grid Portal: VOMS Proxy creation, new features and enhancements

    Energy Technology Data Exchange (ETDEWEB)

    Ardizzone, V.; Barbaram, R.; Falzone, A.; Emidio, G.; Neri, L.; Scardaci, D.; Venuti, N.

    2007-07-01

    Scientific domain knowledge and tools must be presented to the (non-expert) users in terms of applications without needing to know the underlying details of the Grid Middle wares. GENIUS Grid portal, powered by EnginFrame, is an increasingly popular mechanism for creating customisable, Web-based interfaces to Grid services and resources. This work describes new GENIUS portals capabilities such as portal login, access control, display management, new approach to building reusable portal components as plug ins, better performance results as consequence of EnginFrame core functions improvement. Finally will be described two new tools developed for VOMS Proxy creation and simple JDL composer. (Author)

  9. The Biomarker Knowledge System Informatics Pilot Project Supplement To The Biomarker Development Laboratory at Moffitt (Bedlam) — EDRN Public Portal

    Science.gov (United States)

    The Biomarker Knowledge System Informatics Pilot Project goal will develop network interfaces among databases that contain information about existing clinical populations and biospecimens and data relating to those specimens that are important in biomarker assay validation. This protocol comprises one of two that will comprise the Moffitt participation in the Biomarker Knowledge System Informatics Pilot Project. THIS PROTOCOL (58) is the Sput-Epi Database.

  10. Field Demonstration of Active Desiccant-Based Outdoor Air Preconditioning Systems, Final Report: Phase 3; FINAL

    International Nuclear Information System (INIS)

    Fischer, J.

    2001-01-01

    This report summarizes an investigation of the performance of two active desiccant cooling systems that were installed as pilot systems in two locations-a college dormitory and a research laboratory-during the fall of 1999. The laboratory system was assembled in the field from commercially available Trane air-handling modules combined with a standard total energy recovery module and a customized active desiccant wheel, both produced by SEMCO. The dormitory system was a factory-built, integrated system produced by SEMCO that included both active desiccant and sensible-only recovery wheels, a direct-fired gas regeneration section, and a pre-piped Trane heat pump condensing section. Both systems were equipped with direct digital control systems, complete with full instrumentation and remote monitoring capabilities. This report includes detailed descriptions of these two systems, installation details, samples of actual performance, and estimations of the energy savings realized. These pi lot sites represent a continuation of previous active desiccant product development research (Fischer, Hallstrom, and Sand 2000; Fischer 2000). Both systems performed as anticipated, were reliable, and required minimal maintenance. The dehumidification/total-energy-recovery hybrid approach was particularly effective in all respects. System performance showed remarkable improvement in latent load handling capability and operating efficiency compared with the original conventional cooling system and with the conventional system that remained in another, identical wing of the facility. The dehumidification capacity of the pilot systems was very high, the cost of operation was very low, and the system was cost-effective, offering a simple payback for these retrofit installations of approximately 5 to 6 years. Most important, the dormitory system resolved numerous indoor air quality problems in the dormitory by providing effective humidity control and increased, continuous ventilation air

  11. Monitoring system for gamma radiation of porch type for vehicles; Sistema de monitoreo de radiacion gamma tipo portal para vehiculos

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  12. The Portals 4.0 network programming interface.

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin; Wheeler, Kyle Bruce; Hemmert, Karl Scott; Riesen, Rolf E.; Underwood, Keith Douglas; Maccabe, Arthur Bernard; Hudson, Trammell B.

    2012-11-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generation of machines employing advanced network interface architectures that support enhanced offload capabilities.

  13. The portals 4.0.1 network programming interface.

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin; Wheeler, Kyle Bruce; Hemmert, Karl Scott; Riesen, Rolf E.; Underwood, Keith Douglas; Maccabe, Arthur Bernard; Hudson, Trammell B.

    2013-04-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generation of machines employing advanced network interface architectures that support enhanced offload capabilities. 3

  14. Algorithms for contrast enhancement of electronic portal images

    International Nuclear Information System (INIS)

    Díez, S.; Sánchez, S.

    2015-01-01

    An implementation of two new automatized image processing algorithms for contrast enhancement of portal images is presented as suitable tools which facilitate the setup verification and visualization of patients during radiotherapy treatments. In the first algorithm, called Automatic Segmentation and Histogram Stretching (ASHS), the portal image is automatically segmented in two sub-images delimited by the conformed treatment beam: one image consisting of the imaged patient obtained directly from the radiation treatment field, and the second one is composed of the imaged patient outside it. By segmenting the original image, a histogram stretching can be independently performed and improved in both regions. The second algorithm involves a two-step process. In the first step, a Normalization to Local Mean (NLM), an inverse restoration filter is applied by dividing pixel by pixel a portal image by its blurred version. In the second step, named Lineally Combined Local Histogram Equalization (LCLHE), the contrast of the original image is strongly improved by a Local Contrast Enhancement (LCE) algorithm, revealing the anatomical structures of patients. The output image is lineally combined with a portal image of the patient. Finally the output images of the previous algorithms (NLM and LCLHE) are lineally combined, once again, in order to obtain a contrast enhanced image. These two algorithms have been tested on several portal images with great results. - Highlights: • Two Algorithms are implemented to improve the contrast of Electronic Portal Images. • The multi-leaf and conformed beam are automatically segmented into Portal Images. • Hidden anatomical and bony structures in portal images are revealed. • The task related to the patient setup verification is facilitated by the contrast enhancement then achieved.

  15. The Portuguese Climate Portal

    Science.gov (United States)

    Gomes, Sandra; Deus, Ricardo; Nogueira, Miguel; Viterbo, Pedro; Miranda, Miguel; Antunes, Sílvia; Silva, Alvaro; Miranda, Pedro

    2016-04-01

    The Portuguese Local Warming Website (http://portaldoclima.pt) has been developed in order to support the society in Portugal in preparing for the adaptation to the ongoing and future effects of climate change. The climate portal provides systematic and easy access to authoritative scientific data ready to be used by a vast and diverse user community from different public and private sectors, key players and decision makers, but also to high school students, contributing to the increase in knowledge and awareness on climate change topics. A comprehensive set of regional climate variables and indicators are computed, explained and graphically presented. Variables and indicators were built in agreement with identified needs after consultation of the relevant social partners from different sectors, including agriculture, water resources, health, environment and energy and also in direct cooperation with the Portuguese National Strategy for Climate Change Adaptation (ENAAC) group. The visual interface allows the user to dynamically interact, explore, quickly analyze and compare, but also to download and import the data and graphics. The climate variables and indicators are computed from state-of-the-art regional climate model (RCM) simulations (e.g., CORDEX project), at high space-temporal detail, allowing to push the limits of the projections down to local administrative regions (NUTS3) and monthly or seasonal periods, promoting local adaptation strategies. The portal provides both historical data (observed and modelled for the 1971-2000 period) and future climate projections for different scenarios (modelled for the 2011-2100 period). A large effort was undertaken in order to quantify the impacts of the risk of extreme events, such as heavy rain and flooding, droughts, heat and cold waves, and fires. Furthermore the different climate scenarios and the ensemble of RCM models, with high temporal (daily) and spatial (~11km) detail, is taken advantage in order to

  16. Filling the Gaps in a Fragmented Health Care System : Development of the Health and Welfare Information Portal (ZWIP)

    NARCIS (Netherlands)

    Robben, Sarah H. M.; Huisjes, Mirjam; van Achterberg, Theo; Zuidema, Sytse U.; Rikkert, Marcel G. M. Olde; Schers, Henk J.; Heinen, Maud M.; Melis, Rene J. F.

    2012-01-01

    Background: Current health care systems are not optimally designed to meet the needs of our aging populations. First, the fragmentation of care often results in discontinuity of care that can undermine the quality of care provided. Second, patient involvement in care decisions is not sufficiently

  17. Filling the Gaps in a Fragmented Health Care System: Development of the Health and Welfare Information Portal (ZWIP)

    NARCIS (Netherlands)

    Robben, S.H.M.; Huisjes, M.; van Achterberg, T.; Zuidema, S.; Olde Rikkert, M.G.M.; Schers, H.J.; Heinen, M.M.; Melis, R.J.F.

    2012-01-01

    Background: Current health care systems are not optimally designed to meet the needs of our aging populations. First, the fragmentation of care often results in discontinuity of care that can undermine the quality of care provided. Second, patient involvement in care decisions is not sufficiently

  18. Kentucky health system starts online consumer portal program. Web site development aims to drive consumerism and market service lines.

    Science.gov (United States)

    2007-01-01

    Saint Joseph HealthCare in Lexington, KY, is a three-hospital health system comprised of more than 650 beds serving the state's central and eastern regions. As a leading provider in cardiology, orthopedics, and stroke, it was recognized in 2006 as a top hospital in the nation by U.S. News and World Report.

  19. A review of portal screen-film technology and five radiologists' evaluations of some existing products.

    Science.gov (United States)

    Walker, M A; Steinheimer, D N; Weir, V A; Homco, L D; Green, R W; Morris, E L; Hess, M E

    1999-01-01

    Portal radiographs, radiographs made to document the accuracy of radiotherapy treatment fields, are typically of poor image contrast. Recently, a new portal film and screened-cassette system was marketed, the Kodak EC-L system, with the claim of greatly improved image contrast. This new EC-L system was tested on a canine cadaver exposed to Cobalt-60 teletherapy gamma radiation, and image quality was compared to earlier marketed Kodak portal film products. The EC-L system was found to provide portal images of improved contrast/quality.

  20. Portal verification for breast cancer radiotherapy

    International Nuclear Information System (INIS)

    Petkovska, Sonja; Pejkovikj, Sasho; Apostolovski, Nebojsha

    2013-01-01

    At the University Clinic in Skopje, breast cancer irradiation is being planned and performed by using a mono-iso centrical method, which means that a unique isocenter (I C) for all irradiation fields is used. The goal of this paper is to present the patient’s position in all coordinates before the first treatment session, relative to the position determined during the CT simulation. Deviation of up to 5 mm is allowed. The analysis was made by using a portal verification. Sixty female patients at random selection are reviewed. The matching results show that for each patient deviation exists at least on one axis. The largest deviations are in the longitudinal direction (head-feet) up to 4 mm, mean 1.8 mm. In 60 out of 85 analysed fields, the deviation is towards the head. In lateral direction, median deviation is 1.1 mm and in 65% of the analysed portals those deviations are in medial direction – contralateral breast which can increases the dose in the lung and in the contralateral breast. This deviation for supraclavicular field can increase the dose in the spinal cord. Although these doses are well below the limit, this fact should be taken into account in setting the treatment fields. The final conclusion from the research is that despite of the fact we are dealing with small deviations, in conditions when accuracy in positioning is done with portal, the portal verification needs to be done in the coming weeks of the treatment, not only before the first treatment. This provides information for an intra fractional set-up deviation. (Author)

  1. A Climate Information Portal for Copernicus: a central portal for European climate services?

    Science.gov (United States)

    Juckes, Martin; Swart, Rob; Thysse, Peter; Som de Cerff, Wim; Groot, Annemarie; Bennett, Victoria; Costa, Luis; Lückenkötter, Johannes; Callaghan, Sarah

    2015-04-01

    The FP7 project "Climate Information Portal for Copernicus" (CLIPC) is developing a demonstration portal for the Copernicus Climate Change Service (C3S). This project is one of a suite of FP7 research activities which are administratively independent of Copernicus, focussed on creating the technical and scientific building blocks needed for the service. It is to be expected that at EGU 2015 there will be many presentations describing portals delivering new and innovative ranges of services. It would be unwise to seek to replace all this creative activity with a single portal -- instead CLIPC is designing a portal to make distributed resources more accessible through flexible discovery systems. CLIPC needs to deliver more than a directory of resources: resources need to be presented in common protocols so that users can access multiple datasets. More information about the project objectives is available at www.clipc.eu. The gulf between the climate science communities and the end user communities is a central challenge being addressed in the project. It is important to understand that there is significant diversity and multiple communication barriers within these two sets of communities as well as between them. The CLIPC services must presentation will provide a review of progress towards this ambitious goal, through a discussion of user requirements activities, an overview of the proposed architecture, work on assessing and adjusting model biasses, and a discussion of the climate impact indicators which will be provided through the portal. When looking at the usability of data for the various users, CLIPC will implement a set of services functioning as a "knowledge base" supplying information to users about the data, including definitions of terminology used, quality of datasets, versioning, and user annotations.

  2. Passive nuclear material detection in a personnel portal

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Eaton, M.J.

    1979-01-01

    The concepts employed in the development of gamma-ray and neutron detection systems for a special nuclear materials booth portal monitor are described. The portal is designed for unattended use in detecting diversion by a technically sophisticated adversary and has possible application to International Atomic Energy Agency safeguards of a fast critical assembly facility. Preliminary evaluation results are given and plans for further parameter studies are noted

  3. Filling the Gaps in a Fragmented Health Care System: Development of the Health and Welfare Information Portal (ZWIP)

    OpenAIRE

    Robben, Sarah HM; Huisjes, Mirjam; van Achterberg, Theo; Zuidema, Sytse U; Olde Rikkert, Marcel GM; Schers, Henk J; Heinen, Maud M; Melis, Ren? JF

    2012-01-01

    Background: Current health care systems are not optimally designed to meet the needs of our aging populations. First, the fragmentation of care often results in discontinuity of care that can undermine the quality of care provided. Second, patient involvement in care decisions is not sufficiently facilitated. Objective: To describe the development and the content of a program aimed at: (1) facilitating self-management and shared decision making by frail older people and informal caregivers, a...

  4. Assessment of private hospital portals: A conceptual model

    Directory of Open Access Journals (Sweden)

    Mehdi Alipour-Hafezi

    2016-01-01

    Full Text Available Introduction: Hospital portals, as the first virtual entry, play an important role in connecting people with hospital and also presenting hospital virtual services. The main purpose of this article was to suggest a conceptual model to improve Tehran private hospital portals. The suggested model can be used by all the health portals that are in the same circumstances and all the health portals which are in progress. Method: This is a practical research, using evaluative survey research method. Research population includes all the private hospital portals in Tehran, 34 portals, and ten top international hospital portals. Data gathering tool used in this research was a researcher-made checklist including 14 criteria and 77 sub-criteria with their weight score. In fact, objective observation with the mentioned checklist was used to gather information. Descriptive statistics were used to analyze the data and tables and graphs were used to present the organized data. Also, data were analyzed using independent t-test. Conceptual modeling technique was used to design the model and demonstration method was used to evaluate the proposed model. In this regard, SPSS statistical software was used to perform the tests. Results:The comparative study between the two groups of portals, TPH and WTH, in the 14 main criteria showed that the value of t-test in contact information criteria was 0.862, portal page specification was -1.378, page design criteria -1.527, updating pages -0.322, general information and access roads -3.161, public services -7.302, patient services -4.154, patient data -8.703, research and education -9.155, public relationship -3.009, page technical specifications -4.726, telemedicine -7.488, pharmaceutical services -6.183, and financial services -2.782. Finally, the findings demonstrated that Tehran private hospital portals in criterion of contact information were favorable; page design criteria were relatively favorable; page technical

  5. New ICPP portal monitor

    International Nuclear Information System (INIS)

    Georgeson, M.A.; Nichols, C.E.

    1981-04-01

    A large area gas filled proportional-detector portal monitor mounted in a swinging door frame has been designed and developed at the Idaho Chemical Processing Plant (ICPP). This monitor extends the sensitivity and speed of personnel contamination detection to levels equal to or exceeding that obtained using hand-held portable survey techniques. The new monitor has state-of-the-art electronics which result in rapid response, and use statistical principles in the alarm logic to reduce or eliminate spurious alarms. In addition, the evaluation of this instrument indicates that it will detect small enough quantities of U-235 in shielded containers to meet current special nuclear materials (SNM) detection standards. Simultaneous detection of very low level contamination and small quantities of SNM results in a monitor particularly useful for nuclear installations

  6. Systems study 'Alternative Entsorgung'. Final report. Technical annex 6

    International Nuclear Information System (INIS)

    1984-08-01

    In the conditioning plant, fuel elements which have been stored for ten years are loaded into transport containers, unloaded, identified and welded into a dry storage box. The dry store barrel is introduced into a final storage container, which, after being closed, is packed in lost shielding. This so-called final storage barrel is finally placed in a transport container and leaves the conditioning plant in this form by rail for transport to the final storage mine. The fuel element method of treatment 'packing of three complete fuel elements' was used as the reference process. In addition, the method of treatment 'fuel elements dismantled into fuel rods' was also examined. The handling of fuel elements and secondary waste treatment in the reference process are described in detail. (orig./HP) [de

  7. Congestive index of portal vein

    International Nuclear Information System (INIS)

    Kim, Won Ho; Kim, H. K.; Lee, S. C.; Han, S. H.; Han, K. H.; Chung, J. B.; Choi, H. J.

    1989-01-01

    In patients with portal hypertension, the blood flow volume is maintained despite decreased blood flow velocity due to enlargement of the vascular cross sectional area. Thus, the 'congestion index' of the portal vein, which is the ratio between the cross sectional area (cm2) and the blood flow velocity (cm/sec) determined by a Doppler ultrasonography, may be a sensitive index by which to assess portal hypertension. We performed Doppler ultrasonography on 24 normal subjects, 14 patients with biopsy proved chronic active hepatitis and 55 patients with liver cirrhosis in order to assess the diagnostic value of the congestion index. The cross sectional area of the portal vein was significantly enlarged and the mean blood flow velocity was significantly reduced in patients with liver cirrhosis compared with controls. However, the blood flow volume was no difference. The congestion index of the portal vein was significantly increased in patients with liver cirrhosis (0.113+0.035) compared with patients with chronic active hepatitis(0.078+0.029) (p<0.001) and controls (0.053+0.016) (p<0.001). The sensitivity, specificity and predictability of the congestion index for detection of patients with the cirrhosis of the liver were 76.4%, 100% and 100% respectively, when the normal range was set at mean+2SD. The results suggest that the congestion index of the portal vein may pla a significant role in diagnosis of portal hypertensive patients

  8. A final focus system for the Next Linear Collider

    International Nuclear Information System (INIS)

    Zimmermann, F.; Brown, K.; Emma, P.; Helm, R.; Irwin, J.; Tenenbaum, P.; Wilson, P.

    1995-06-01

    The final focus of the Next Linear Collider (NLC) demagnifies electron and positron beams of 250--750 GeV energy down to a transverse size of about 2.5 x 350 nm 2 at the interaction point (IP). The basic layout, momentum bandwidth, vibration tolerances, wakefield effects, and the tunability of the proposed final focus design are discussed. Also a perspective is given on the crab cavity and on effects of the solenoid field in the interaction region

  9. Hyperammonaemia, plasma aminoacid imbalance, and blood-brain aminoacid transport: a unified theory of portal-systemic encephalopathy.

    Science.gov (United States)

    James, J H; Ziparo, V; Jeppsson, B; Fischer, J E

    1979-10-13

    It is proposed that hyperammonaemia in liver cirrhosis or after portacaval shunt contributes to plasma neutral aminoacid imbalance and to increased activity of the blood-brain neutral amino-acid transport system. Plasma neutral aminoacid concentrations are deranged, partly, but not completely, because ammonia stimulates glucagon secretion; a high rate of gluconeogenesis and hyperinsulinaemia follow. Brain uptake of neutral aminoacids rises because ammonia stimulates brain-glutamine synthesis, which results in rapid exchange of brain glutamine for plasma neutral aminoacids. Hyperammonaemia therefore contributes to encephalopathy indirectly, by raising the brain concentration of neutral aminoacids which after neurotransmitter metabolism, rather than directly, by toxic effects on neuronal metabolism.

  10. Liferay 6.x portal enterprise intranets cookbook

    CERN Document Server

    Filipowicz, Piotr

    2015-01-01

    If you are a Java developer or administrator with a technical background and want to install and configure Liferay Portal as an enterprise intranet, this is the book for you. In short, reusable recipes help you realize business goals as working features in Liferay. This book will also give you useful hints on how to easily improve the default functionality of the system and its performance.

  11. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Gao, Q.H.; Xie, H.; Nelson, D.F.; Yu, Y.; Kwok, W.E.; Totterman, S.; Schell, M.C.; Rubin, P.

    1996-01-01

    and marrow information within the skull. Next, a ray-tracing method is used to generate a projection (pseudo-portal) image at the planned treatment position. In this situation, the ray-tracing is simply performed on pixels rather than attenuation coefficients. The skull and its relative positions are also projected to the pseudo-portal image and are used as 'hint' for the search of similar features in the portal images. A Canny edge detector is applied to the region of treatment field and is used to enhance brain contour and skull. The skull in the brain is then identified using a snake technique which is guided by the ''hint'', the projected features from MR images. Finally, a Chamfer matching technique is used to correlate features between the MR projection and portal images. Results: MR image-guided portal verification technique is evaluated using a clinical patient case who has an astrocytoma brain tumor and is treated by radiation therapy. The segmented results for brain MR slice images indicate that a wavelet-based image segmentation technique provides a reasonable estimation for the brain skull. Compared to the brain portal image, the method developed in this study for the generation of brain projection images provides skull structure about 3 mm differences. However, overall matching results are within 2 mm compared to the results between portal and simulation images. In addition, tumor volume can be accurately visualized in the projection image and be mapped over to portal images for treatment verification with this approach. Conclusions: A method for MR image-guided portal verification of brain treatment field is being developed. Although the projection image from MR images dose not have the similar radiographic appearance as portal images, it provides certain essential anatomical features (landmarks and gross tumor) as well as their relative locations to be used as references for computerized portal verification

  12. LOFT integral test system final safety analysis report

    International Nuclear Information System (INIS)

    1974-03-01

    Safety analyses are presented for the following LOFT Reactor systems: engineering safety features; support buildings and facilities; instrumentation and controls; electrical systems; and auxiliary systems. (JWR)

  13. The NUCLEONICA Nuclear Science Portal

    International Nuclear Information System (INIS)

    Magill, Joseph; Dreher, Raymond

    2009-01-01

    NUCLEONICA (www.nucleonica.net) is a new nuclear science web portal which provides a customisable, integrated environment and collaboration platform using the latest internet 'Web 2.0' technology. NUCLEONICA is aimed at professionals, academics and students working in nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. A unique feature of the portal is the wide range of user friendly web-based nuclear science applications. The portal is also ideal for education and training purposes and as a knowledge management platform to preserve nuclear knowledge built up over many decades.

  14. Information Portal Costs and Benefits

    Directory of Open Access Journals (Sweden)

    Lorena BATAGAN

    2006-01-01

    Full Text Available All transformations of our society are the product of the large use of Information and Communications Technologies (ICT and Internet. ICT are technologies which facilitate communication, processing, and transmission of information by electronic means. It is very important to use the new technologies to the correct value because this determinate an increase of global benefits. Portal provides a consistent way to select, evaluate, prioritize and plan the right information. In research we point the important costs and benefits for an informational portal. The portal for local administrative determinate for citizens the access to information of interest and on the other hand make easier for employer to manage the documents.

  15. The Higgs Portal and Cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Assamagan, Ketevi [Brookhaven National Lab. (BNL), Upton, NY (United States); Chen, Chien-Yi [Perimeter Inst. for Theoretical Physics, Waterloo, ON (Canada); Univ. of Victoria, BC (Canada); Chou, John Paul [Rutgers Univ., Piscataway, NJ (United States); Curtin, David [Univ. of Maryland, College Park, MD (United States); Fedderke, Michael A. [Univ. of Chicago, IL (United States); Gershtein, Yuri [Rutgers Univ., Piscataway, NJ (United States); He, Xiao-Gang [Shanghai Jiao Tong Univ. (China); Klute, Markus [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Kozaczuk, Jonathon [TRIUMF, Vancouver, BC (Canada); Kotwal, Ashutosh [Duke Univ., Durham, NC (United States); Lowette, Steven [Vrije Univ., Brussels (Belgium); No, Jose Miguel [Univ. of Sussex, Brighton (United Kingdom); Plehn, Tilman [Heidelberg Univ. (Germany); Qian, Jianming [Univ. of Michigan, Ann Arbor, MI (United States); Ramsey-Musolf, Michael [Univ. of Massachusetts, Amherst, MA (United States); Safonov, Alexei [Texas A & M Univ., College Station, TX (United States); Shelton, Jessie [Univ. of Illinois, Urbana-Champaign, IL (United States); Spannowsky, Michael [Durham Univ. (United Kingdom); Su, Shufang [Univ. of Arizona, Tucson, AZ (United States); Walker, Devin G. E. [Univ. of Washington, Seattle, WA (United States); Willocq, Stephane [Univ. of Massachusetts, Amherst, MA (United States); Winslow, Peter [Univ. of Massachusetts, Amherst, MA (United States)

    2016-04-18

    Higgs portal interactions provide a simple mechanism for addressing two open problems in cosmology: dark matter and the baryon asymmetry. In the latter instance, Higgs portal interactions may contain the ingredients for a strong first-order electroweak phase transition as well as new CP-violating interactions as needed for electroweak baryogenesis. These interactions may also allow for a viable dark matter candidate. We survey the opportunities for probing the Higgs portal as it relates to these questions in cosmology at the LHC and possible future colliders.

  16. LimsPortal and BonsaiLIMS: development of a lab information management system for translational medicine.

    Science.gov (United States)

    Bath, Timothy G; Bozdag, Selcuk; Afzal, Vackar; Crowther, Daniel

    2011-05-13

    Laboratory Information Management Systems (LIMS) are an increasingly important part of modern laboratory infrastructure. As typically very sophisticated software products, LIMS often require considerable resources to select, deploy and maintain. Larger organisations may have access to specialist IT support to assist with requirements elicitation and software customisation, however smaller groups will often have limited IT support to perform the kind of iterative development that can resolve the difficulties that biologists often have when specifying requirements. Translational medicine aims to accelerate the process of treatment discovery by bringing together multiple disciplines to discover new approaches to treating disease, or novel applications of existing treatments. The diverse set of disciplines and complexity of processing procedures involved, especially with the use of high throughput technologies, bring difficulties in customizing a generic LIMS to provide a single system for managing sample related data within a translational medicine research setting, especially where limited IT support is available. We have designed and developed a LIMS, BonsaiLIMS, around a very simple data model that can be easily implemented using a variety of technologies, and can be easily extended as specific requirements dictate. A reference implementation using Oracle 11 g database and the Python framework, Django is presented. By focusing on a minimal feature set and a modular design we have been able to deploy the BonsaiLIMS system very quickly. The benefits to our institute have been the avoidance of the prolonged implementation timescales, budget overruns, scope creep, off-specifications and user fatigue issues that typify many enterprise software implementations. The transition away from using local, uncontrolled records in spreadsheet and paper formats to a centrally held, secured and backed-up database brings the immediate benefits of improved data visibility, audit and

  17. LimsPortal and BonsaiLIMS: development of a lab information management system for translational medicine

    Directory of Open Access Journals (Sweden)

    Afzal Vackar

    2011-05-01

    Full Text Available Abstract Background Laboratory Information Management Systems (LIMS are an increasingly important part of modern laboratory infrastructure. As typically very sophisticated software products, LIMS often require considerable resources to select, deploy and maintain. Larger organisations may have access to specialist IT support to assist with requirements elicitation and software customisation, however smaller groups will often have limited IT support to perform the kind of iterative development that can resolve the difficulties that biologists often have when specifying requirements. Translational medicine aims to accelerate the process of treatment discovery by bringing together multiple disciplines to discover new approaches to treating disease, or novel applications of existing treatments. The diverse set of disciplines and complexity of processing procedures involved, especially with the use of high throughput technologies, bring difficulties in customizing a generic LIMS to provide a single system for managing sample related data within a translational medicine research setting, especially where limited IT support is available. Results We have designed and developed a LIMS, BonsaiLIMS, around a very simple data model that can be easily implemented using a variety of technologies, and can be easily extended as specific requirements dictate. A reference implementation using Oracle 11 g database and the Python framework, Django is presented. Conclusions By focusing on a minimal feature set and a modular design we have been able to deploy the BonsaiLIMS system very quickly. The benefits to our institute have been the avoidance of the prolonged implementation timescales, budget overruns, scope creep, off-specifications and user fatigue issues that typify many enterprise software implementations. The transition away from using local, uncontrolled records in spreadsheet and paper formats to a centrally held, secured and backed-up database brings the

  18. Hands-on approach to teaching Earth system sciences using a information-computational web-GIS portal "Climate"

    Science.gov (United States)

    Gordova, Yulia; Gorbatenko, Valentina; Martynova, Yulia; Shulgina, Tamara

    2014-05-01

    A problem of making education relevant to the workplace tasks is a key problem of higher education because old-school training programs are not keeping pace with the rapidly changing situation in the professional field of environmental sciences. A joint group of specialists from Tomsk State University and Siberian center for Environmental research and Training/IMCES SB RAS developed several new courses for students of "Climatology" and "Meteorology" specialties, which comprises theoretical knowledge from up-to-date environmental sciences with practical tasks. To organize the educational process we use an open-source course management system Moodle (www.moodle.org). It gave us an opportunity to combine text and multimedia in a theoretical part of educational courses. The hands-on approach is realized through development of innovative trainings which are performed within the information-computational platform "Climate" (http://climate.scert.ru/) using web GIS tools. These trainings contain practical tasks on climate modeling and climate changes assessment and analysis and should be performed using typical tools which are usually used by scientists performing such kind of research. Thus, students are engaged in n the use of modern tools of the geophysical data analysis and it cultivates dynamic of their professional learning. The hands-on approach can help us to fill in this gap because it is the only approach that offers experience, increases students involvement, advance the use of modern information and communication tools. The courses are implemented at Tomsk State University and help forming modern curriculum in Earth system science area. This work is partially supported by SB RAS project VIII.80.2.1, RFBR grants numbers 13-05-12034 and 14-05-00502.

  19. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Kim, Yon-Lae; Chung, Jin-Beom; Kim, Jae-Sung; Lee, Jeong-Woo; Choi, Kyoung-Sik

    2014-01-01

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ % ≤1, γ avg < 0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  20. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yon-Lae [Choonhae College of Health Sciences, Ulsan (Korea, Republic of); The Catholic University of Korea, Seoul (Korea, Republic of); Chung, Jin-Beom; Kim, Jae-Sung [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Lee, Jeong-Woo [Konkuk University Medical Center, Seoul (Korea, Republic of); Choi, Kyoung-Sik [SAM Anyang Hospital, Anyang (Korea, Republic of)

    2014-04-15

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ{sub %}≤1, γ{sub avg} < 0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  1. The DIRAC Web Portal 2.0

    Science.gov (United States)

    Mathe, Z.; Casajus Ramo, A.; Lazovsky, N.; Stagni, F.

    2015-12-01

    For many years the DIRAC interware (Distributed Infrastructure with Remote Agent Control) has had a web interface, allowing the users to monitor DIRAC activities and also interact with the system. Since then many new web technologies have emerged, therefore a redesign and a new implementation of the DIRAC Web portal were necessary, taking into account the lessons learnt using the old portal. These new technologies allowed to build a more compact, robust and responsive web interface that enables users to have better control over the whole system while keeping a simple interface. The web framework provides a large set of “applications”, each of which can be used for interacting with various parts of the system. Communities can also create their own set of personalised web applications, and can easily extend already existing ones with a minimal effort. Each user can configure and personalise the view for each application and save it using the DIRAC User Profile service as RESTful state provider, instead of using cookies. The owner of a view can share it with other users or within a user community. Compatibility between different browsers is assured, as well as with mobile versions. In this paper, we present the new DIRAC Web framework as well as the LHCb extension of the DIRAC Web portal.

  2. The Portals 4.1 Network Programming Interface

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian; Brightwell, Ronald B.; Grant, Ryan; Hemmert, Karl Scott; Pedretti, Kevin; Wheeler, Kyle; Underwood, Keith D; Riesen, Rolf; Maccabe, Arthur B.; Hudson, Trammel

    2017-04-01

    This report presents a specification for the Portals 4 networ k programming interface. Portals 4 is intended to allow scalable, high-performance network communication betwee n nodes of a parallel computing system. Portals 4 is well suited to massively parallel processing and embedded syste ms. Portals 4 represents an adaption of the data movement layer developed for massively parallel processing platfor ms, such as the 4500-node Intel TeraFLOPS machine. Sandia's Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4 is tar geted to the next generation of machines employing advanced network interface architectures that support enh anced offload capabilities.

  3. Knowledge portal: a tool to capture university requirements

    Science.gov (United States)

    Mansourvar, Marjan; Binti Mohd Yasin, Norizan

    2011-10-01

    New technologies, especially, the Internet have made a huge impact on knowledge management and information dissemination in education. The web portal as a knowledge management system is very popular topics in many organizations including universities. Generally, a web portal defines as a gateway to online network accessible resources through the intranet, extranet or Internet. This study develops a knowledge portal for the students in the Faculty of Computer Science and Information Technology (FCSIT), University of Malaya (UM). The goals of this portal are to provide information for the students to help them to choose the right courses and major that are relevant to their intended future jobs or career in IT. A quantitative approach used as the selected method for this research. Quantitative method provides an easy and useful way to collect data from a large sample population.

  4. Portal hypertension: a review of portosystemic collateral pathways and endovascular interventions.

    Science.gov (United States)

    Pillai, A K; Andring, B; Patel, A; Trimmer, C; Kalva, S P

    2015-10-01

    The portal vein is formed at the confluence of the splenic and superior mesenteric vein behind the head of the pancreas. Normal blood pressure within the portal system varies between 5 and 10 mmHg. Portal hypertension is defined when the gradient between the portal and systemic venous blood pressure exceeds 5 mmHg. The most common cause of portal hypertension is cirrhosis. In cirrhosis, portal hypertension develops due to extensive fibrosis within the liver parenchyma causing increased vascular resistance. In addition, the inability of the liver to metabolise certain vasodilators leads to hyperdynamic splanchnic circulation resulting in increased portal blood flow. Decompression of the portal pressure is achieved by formation of portosystemic collaterals. In this review, we will discuss the pathophysiology, anatomy, and imaging findings of spontaneous portosystemic collaterals and clinical manifestations of portal hypertension with emphasis on the role of interventional radiology in the management of complications related to portal hypertension. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Systems study 'Alternative Entsorgung'. Final report. Technical annex 10

    International Nuclear Information System (INIS)

    Hartje, B.; Kronschnabel, H.; Mueller, W.F.W.

    1984-01-01

    There is an investigation whether accessibility can be produced to fuel elements stored in a salt mine. All solutions of the problem were followed up until the technically best one was found. Two conditions must be fulfilled for access to the final storage barrel: - There must be a climate which is suitable for people. The Mining Order is the basis for this. - The pit building must be fixed, in the convergence in the salt mine should not lead to it becoming impossible to reach part of the mine. Due to heat-producing waste, rock temperatures are caused in the salt mine, in which mining is no longer possible. Building on the idea of cooling the whole final storage area using concentric sections, the amount of heat to be removal was first estimated. Cooling of the whole final storage area proved to be technically unjustifiable and uninteresting at present. (orig./HP) [de

  6. Arteriomesentericography in patients with extrahepatic forms of portal hypertension

    International Nuclear Information System (INIS)

    Semenov, V.S.; Gotman, L.N.

    1980-01-01

    The reverse contrast examination of the system, carried out by means of superior arteriomesentericography, is the optimal method for diagnosing pathological changes in the portal channel of splenectomized patients with the syndrome of the extrahepatic form of portal hypertension. The selective catheterization of the superior mesenteric artery was made in 36 patients with the prerenal block of the portal system. In all cases the venous phase of portography was obtained, which served as a basis for selecting the amount of surgical intervention in these patients. Depending on the level of the block of the portal channel, the patients fell into 3 groups. The characteristic X-ray appearance of portal hypertension, manifested mainly by the presence of portoportal and portocaval collaterals, is described for each group. The thrombosis of the main vessels of the loose type of their structure excludes the possibility of portocaval anastomosis, while in the presence of the pronounced surgical trunk of the superior mesenteric vein vascular shunting may be recommended. Portal hypertension, in contrast to the normal state, requires prolonged contrast examination of the venous phase due to a slower portorenal blood flow

  7. Ozone (Environmental Health Student Portal)

    Science.gov (United States)

    Skip Navigation National Library of Medicine Environmental Health Student Portal Connecting Middle School Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor ...

  8. Pesticides (Environmental Health Student Portal)

    Science.gov (United States)

    Skip Navigation National Library of Medicine Environmental Health Student Portal Connecting Middle School Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor ...

  9. The ATF [Advanced Toroidal Facility] Data Management System: [Final report

    International Nuclear Information System (INIS)

    Kannan, K.L.; Baylor, L.R.

    1987-01-01

    The Advanced Toroidal Facility (ATF) Data Management System (DMG) is a VAX-based software system that provides unified data access for ATF data acquisition and analysis. The system was designed with user accessibility, software maintainability, and extensibility as primary goals. This paper describes the layered architecture of the system design, the system implementation, use, and the data file structure. 3 refs., 1 fig

  10. Final Report. Novel Behavior of Ferromagnet/Superconductor Hybrid Systems

    Energy Technology Data Exchange (ETDEWEB)

    Birge, Norman [Michigan State Univ., East Lansing, MI (United States)

    2016-09-26

    Final report for grant DE-FG02-06ER46341. This work has produced a most convincing experimental demonstration that spin-triplet supercurrent can appear in Josephson junctions containing ferromagnetic materials, even when the superconducting electrodes are conventional, spin-singlet superconductors.

  11. Final Report. Novel Behavior of Ferromagnet/Superconductor Hybrid Systems

    International Nuclear Information System (INIS)

    Birge, Norman

    2016-01-01

    Final report for grant DE-FG02-06ER46341. This work has produced a most convincing experimental demonstration that spin-triplet supercurrent can appear in Josephson junctions containing ferromagnetic materials, even when the superconducting electrodes are conventional, spin-singlet superconductors.

  12. Mechanical characterization of the Varian Exact-arm and R-arm support systems for eight aS500 electronic portal imaging devices

    International Nuclear Information System (INIS)

    Grattan, Mark W. D.; McGarry, Conor K.

    2010-01-01

    Purpose: The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm. Methods: The mechanical performance of the two arm systems was compared by investigating the variation in sensitivity with gantry angle, both before and after the EPID position was adjusted after gantry rotation. Positional errors were investigated by subtracting images from a reference image taken at gantry 0 deg., and the amplitude of the peaks and troughs at the field edges for longitudinal (radial) and lateral (transverse) profiles across the resulting image was related to the distance of displacement. Calibration curves based on a pixel-by-pixel shift were generated for each EPID and the Varian hand pendant accuracy was compared to the calibration data. Results: The response of the EPIDs was found to change with gantry rotation, with the largest difference at 180 deg. The Exact-arm was found to correct well for any displacement, while the R-arm tended to overcorrect following repositioning using the hand pendant. The calibration curves were consistent within each set of matched linacs, and the hand pendant accuracy was similar for both arm systems, although generally in different directions. With respect to gantry rotation effects, the mechanical performance of the Exact-arm systems was found to be much better than that of the R-arm systems. At gantry positions 90 deg., 270 deg., and 180 deg. the average misalignment in the longitudinal direction was +4.2±0.2, +1.8±1.6, and +7.4±0.5 mm for the R-arms, and +2.9±0.2, +2.1±0.8, and +4.9±0.7 mm for the Exact-arms. In the lateral direction the average positional errors were +2.1±0.4, -4.7±0.4, and -2.5

  13. Knowledge Management Portal: A Simplified Model to Help Decision Makers

    International Nuclear Information System (INIS)

    Ogawa, I.; Hernandes Tabares, R.

    2015-01-01

    The aim of this work is to present a simplified model that could help the nuclear industry to keep the expertise of safeguards professionals in touch with the state of the art, and also to have available information in the Portal of Knowledge Management. It can also provide indicators and general data for decision makers. Authors have developed the concept based on their own experience through systems running in hydroelectric and gas fired plants, and one exclusive system that manage all courses in one University. It is under development a Portal of Knowledge Management for NPP dealing with information obtained of Strategic Plans, Budgets and Economics, Operation Performance, Maintenance and Surveillance Plans, Training and Education Programs, QA Programs, Operational Experience, Safety Culture, and Engineering of Human Factors. This model will provide indicators for decision makers. Training and education module is prepared according to profile of each individual and his attributes, tasks and capabilities, and training and education programmes. The system could apply self-assessment questionnaires; immersive learning using media (video) classes, and test applications using questions randomly selected from data bank, as well as could make applications to certificate people. All these data are analyzed and generate indicators about strongest and weakness points. Managers could have indication of individual's deficiency even though in training programmes on a real time basis. Another tool that could be applied to the model is the remote operation of supervision equipment. The model is developed using web-based tools, like ASP.NET encrypted by 128 bits, and web site https. Finally, it is important to stress that the model can be customized according to industry preference. (author)

  14. B-Plant Canyon Ventilation Control System Description; FINAL

    International Nuclear Information System (INIS)

    MCDANIEL, K.S.

    1999-01-01

    Project W-059 installed a new B Plant Canyon Ventilation System. Monitoring and control of the system is implemented by the Canyon Ventilation Control System (CVCS). This document describes the CVCS system components which include a Programmable Logic Controller (PLC) coupled with an Operator Interface Unit (OIU) and application software. This document also includes an Alarm Index specifying the setpoints and technical basis for system analog and digital alarms

  15. NNWSI project information management system concepts evaluation report. Final report

    International Nuclear Information System (INIS)

    1986-08-01

    This report is intended as a first step in developing detailed information management system specifications for the Nevada Nuclear Waste Storage Investigations (NNWSI) Project. The current state of information management at the NNWSI Project level is investigated and an information management system (IMS) is proposed. The IMS as it relates to aspects of Project and records management is discussed. Information management concepts and prospective IMS system components are investigated. Concepts and system components include: indexing, searching, retrieval, data base management system technology, computers, storage media, computer-assisted retrieval (CAR) of microfilm, electronic imaging-based systems, optical character recognition, and communications. Performance criteria and desirable system attributes applicable to the IMS are discussed. Six conceptual system approaches capable of satisfying the performance criteria are defined. System approaches include: fully centralized microfilm system based on CAR retrieval (Approach 1), partially distributed microfilm system based on CAR retrieval (Approach 2), fully distributed microfilm system based on CAR retrieval (Approach 3), fully centralized optical disk system based on electronic image and full-text retrieval (Approach 4), partially distributed optical system based on electron image and full-text retrieval (Approach 5), and fully distributed optical disk system based on electronic image and full-text retrieval (Approach 6). Technical and cost considerations associated with the six conceptual approaches are evaluated. Technical evaluation results indicate Approach 4 is the best conceptual approach, and cost evaluation results show no significant differences among approaches. On the basis of the evaluation, Approach 4 is recommended

  16. Protection of estrogen in portal hypertension gastropathy: an experimental model

    Directory of Open Access Journals (Sweden)

    Maria Isabel Morgan-Martins

    2011-09-01

    Full Text Available CONTEXT: Portal hypertension is a complication secondary to cirrhosis that is characterized by increased blood flow and/or vascular resistance in the portal system, causing the appearance of a hyperdynamic collateral circulation. Partial portal vein ligation is an experimental model used in rats to study the pathophysiological mechanisms involved in pre-hepatic portal hypertension. Estrogen E2 is an antioxidant molecule with various physiological actions. OBJECTIVES: To evaluate the antioxidant activity of endogenous estrogen in an experimental model of partial portal vein ligation by comparing intact with castrated rats. METHODS: Twenty Wistar rats, weighing on average 250 g were used and divided into four groups: sham-operated (SO; intact (I with partial portal vein ligation (I + PPVL, castrated (C and castrated with partial ligation of the vein (C + PPVL. Day 1: castration or sham-operation; day 7, PPVL surgery; on day 15 post-PPVL, portal pressure in the mesenteric vein of rats was measured on polygraph Letica. Lipid peroxidation in the stomach was assessed using the technique of thiobarbituric acid reactive substances and activity of antioxidant enzymes superoxide dismutase, catalase and glutathione peroxidase. Statistical analysis was done with ANOVA - Student-Newman-Keuls (mean ± SE, and P<0.05 was considered as significant. RESULTS: Portal pressure was significantly increased in C + PPVL as compared to the other groups. There was no significant difference in the group of intact rats. TBARS showed significant damage in C and C + PPVL in relation to others. Antioxidant enzymes were significantly increased in the castrated rats with subsequent PPVL as compared to the other groups. CONCLUSION: We suggest that estrogen E2 plays a protective role in intact compared with castrated rats because it presents hydrophenolic radicals in its molecule, thus acting as an antioxidant in this experimental model.

  17. Protection of estrogen in portal hypertension gastropathy: an experimental model.

    Science.gov (United States)

    Morgan-Martins, Maria Isabel; Jacques, Simone Iahnig; Hartmann, Renata Minuzzo; Marques, Camila Moraes; Marroni, Cláudio Augusto; Marroni, Norma Possa

    2011-01-01

    Portal hypertension is a complication secondary to cirrhosis that is characterized by increased blood flow and/or vascular resistance in the portal system, causing the appearance of a hyperdynamic collateral circulation. Partial portal vein ligation is an experimental model used in rats to study the pathophysiological mechanisms involved in pre-hepatic portal hypertension. Estrogen E2 is an antioxidant molecule with various physiological actions. To evaluate the antioxidant activity of endogenous estrogen in an experimental model of partial portal vein ligation by comparing intact with castrated rats. Twenty Wistar rats, weighing on average 250 g were used and divided into four groups: sham-operated (SO); intact (I) with partial portal vein ligation (I + PPVL), castrated (C) and castrated with partial ligation of the vein (C + PPVL). Day 1: castration or sham-operation; day 7, PPVL surgery; on day 15 post-PPVL, portal pressure in the mesenteric vein of rats was measured on polygraph Letica. Lipid peroxidation in the stomach was assessed using the technique of thiobarbituric acid reactive substances and activity of antioxidant enzymes superoxide dismutase, catalase and glutathione peroxidase. Statistical analysis was done with ANOVA - Student-Newman-Keuls (mean ± SE), and P<0.05 was considered as significant. Portal pressure was significantly increased in C + PPVL as compared to the other groups. There was no significant difference in the group of intact rats. TBARS showed significant damage in C and C + PPVL in relation to others. Antioxidant enzymes were significantly increased in the castrated rats with subsequent PPVL as compared to the other groups. We suggest that estrogen E2 plays a protective role in intact compared with castrated rats because it presents hydrophenolic radicals in its molecule, thus acting as an antioxidant in this experimental model.

  18. Drainage facility management system : final report, June 2009.

    Science.gov (United States)

    2009-06-01

    This research project identified requirements for a drainage facility management system for the Oregon Department of Transportation. It also estimated the personnel resources needed to collect the inventory to populate such a system with data. A tota...

  19. Power plant system assessment. Final report. SP-100 Program

    International Nuclear Information System (INIS)

    Anderson, R.V.; Atkins, D.F.; Bost, D.S.

    1983-01-01

    The purpose of this assessment was to provide system-level insights into 100-kWe-class space reactor electric systems. Using these insights, Rockwell was to select and perform conceptual design studies on a ''most attractive'' system that met the preliminary design goals and requirements of the SP-100 Program. About 4 of the 6 months were used in the selection process. The remaining 2 months were used for the system conceptual design studies. Rockwell completed these studies at the end of FY 1983. This report summarizes the results of the power plant system assessment and describes our choice for the most attractive system - the Rockwell SR-100G System (Space Reactor, 100 kWe, Growth) - a lithium-cooled UN-fueled fast reactor/Brayton turboelectric converter system

  20. Organic Rankine Kilowatt Isotope Power System. Final phase I report

    International Nuclear Information System (INIS)

    1978-01-01

    On 1 August 1975 under Department of Energy Contract EN-77-C-02-4299, Sundstrand Energy Systems commenced development of a Kilowatt Isotope Power System (KIPS) directed toward satisfying the higher power requirements of satellites of the 1980s and beyond. The KIPS is a 238 PuO 2 fueled organic Rankine cycle turbine power system which will provide design output power in the range of 500 to 2000 W/sub (e)/ with a minimum of system changes. The principal objectives of the Phase 1 development effort were to: conceptually design a flight system; design a Ground Demonstration System (GDS) that is prototypic of the flight system in order to prove the feasibility of the flight system design; fabricate and assemble the GDS; and performance and endurance test the GDS using electric heaters in lieu of the isotope heat source. Results of the work performed under the Phase 1 contract to 1 July 1978 are presented

  1. Exploratory portals of research data in education

    Directory of Open Access Journals (Sweden)

    Di Blas Nicoletta

    2015-12-01

    Full Text Available This paper presents a powerful tool to enhance research in education: ‘exploratory portals’, supporting effective storage, sharing and exploration of large sets of research data. The workflow is the following: data are gathered by a research group; they are then classified according to a taxonomy (the one that best fits the group’s research interest; once uploaded in the portal, they can be ‘explored’ via a combination of faceted search (enriched by Boolean operators and data mining techniques. The system can thus answer in a few seconds to sophisticated user’s queries that otherwise would require hours; it can save a session’s results and materials for sharing with other scholars or for further investigation. The paper presents a case study of exploratory portal, dealing with data on (technology-based education. The portal has effectively been used by five different research groups, to run complex investigations of data about technology integration into schools.

  2. Interfacing system isolation experience review. Final report, August 1991

    International Nuclear Information System (INIS)

    1991-08-01

    A light water reactor power plant has auxiliary systems interconnected with the reactor coolant system that are not designed for reactor operating pressure. These principally include the shutdown heat removal systems and various emergency core cooling injection systems. There are multiple isolation valves that prevent rector vessel pressure from causing overpressurization in low pressure interfacing systems. Combinations of hardware failures or operational errors are necessary to expose these systems to overpressurization. This experience review provides insights regarding the risk that an auxiliary system might become over pressurized from the reactor system. While analyses show that for the pressures involved the probability of auxiliary system failure is low, the auxiliary system conceivably might fail outside of containment while the plant is at power. Such a potential event has come to be called an interfacing system loss of coolant accident (ISLOCA). This report provides a compilation of occurrences where valve leakage, valve failure, or valve mispositioning played a role in the ability to maintain interfacing system isolation. Seventeen U.S. BWR events, twenty three U.S. PWR events and one foreign event are discussed in the report. Eleven of the U.S. BWR events and ten U.S. PWR events are judged to relate directly to the so-called ISLOCA event in that they fulfilled one or more of the failures necessary to cause an ISLOCA. (author)

  3. Idiopathic portal hypertension with regard to thiopurine treatment.

    Science.gov (United States)

    Machlab, Salvador; Miquel, Mireia; Vergara, Mercedes

    2018-04-16

    Idiopathic portal hypertension (IPH) is an infrequent adverse reaction to the use of thiopurines that tends to be overlooked. Herein, we present a patient with ileocolic Crohn's disease treated with azathioprine who presented ascites, esophageal varices and splenomegaly without any signs of liver cirrhosis. A portal hemodynamics study revealed a normal portosystemic gradient compatible with presinusoidal portal hypertension. Finally, IPH was diagnosed after a liver biopsy. IPH secondary to thiopurines is due to a 6-thioguanine nucleotide (6-TGN)-dependent reaction and occurs predominantly between three months and three years after the start of treatment. The onset is usually insidious and thrombocytopenia is the first manifestation. The definitive diagnosis is obtained by liver biopsy.

  4. Solar system installation at Louisville, Kentucky (final report)

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-07

    A contract was awarded in June 1976 for the installation of a solar space heating and domestic hot water system at 2400 Watteroon Trail, Louisville, Kentucky. The overall philosophy used was to install both a liquid and a hot air system retrofitted to the existing office and combined warehouse building. The 1080 sq ft office space is heated first and excess heat is dumped into the warehouse. The two systems offered a unique opportunity to measure the performance and compare results of both air and liquid at one site. The two systems are described in detail and information on the data acquisition system is included.

  5. Technology verification phase. Dynamic isotope power system. Final report

    International Nuclear Information System (INIS)

    Halsey, D.G.

    1982-01-01

    The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight system design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance

  6. Technology verification phase. Dynamic isotope power system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Halsey, D.G.

    1982-03-10

    The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight system design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance. (LCL)

  7. Portal hypertension: Imaging of portosystemic collateral pathways and associated image-guided therapy.

    Science.gov (United States)

    Bandali, Murad Feroz; Mirakhur, Anirudh; Lee, Edward Wolfgang; Ferris, Mollie Clarke; Sadler, David James; Gray, Robin Ritchie; Wong, Jason Kam

    2017-03-14

    Portal hypertension is a common clinical syndrome, defined by a pathologic increase in the portal venous pressure. Increased resistance to portal blood flow, the primary factor in the pathophysiology of portal hypertension, is in part due to morphological changes occurring in chronic liver diseases. This results in rerouting of blood flow away from the liver through collateral pathways to low-pressure systemic veins. Through a variety of computed tomographic, sonographic, magnetic resonance imaging and angiographic examples, this article discusses the appearances and prevalence of both common and less common portosystemic collateral channels in the thorax and abdomen. A brief overview of established interventional radiologic techniques for treatment of portal hypertension will also be provided. Awareness of the various imaging manifestations of portal hypertension can be helpful for assessing overall prognosis and planning proper management.

  8. GO evaluation of a PWR spray system. Final report

    International Nuclear Information System (INIS)

    Long, W.T.

    1975-08-01

    GO is a reliability analysis methodology developed over the years from 1960 to the present by Kaman Sciences Corporation, Colorado Springs, Colorado. In this report the GO methodology is presented and its application demonstrated by performing a reliability analysis of a conceptual PWR Containment Spray System. Certain numerical results obtained are compared with those of a prior fault tree analysis of the same system as documented in the 11 January 1973 draft report, A Fault Tree Evaluation of a PWR Spray System

  9. IOOS Data Portals and Uniform On-line Browse Capabilities

    Science.gov (United States)

    Howard, M.; Currier, R. D.; Kobara, S.; Gayanilo, F.

    2015-12-01

    The Gulf of Mexico Coastal Ocean Observing System Regional Association (GCOOS-RA) is one of eleven Regional Associations organized under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) Program Office. Each of the RAs operate standards-based regional data portals designed to aggregate near real-time and historical observed data and modeled outputs from distributed providers and to offer these and derived products in standardized ways to a diverse set of users. The RA's portals are based on the IOOS Data and Communications Plan which describes the functional elements needed for an interoperable system. One of these elements is called "Uniform On-line Browse" which is an informational service designed primarily to visualize the inventory of a portal. An on-line browse service supports the end user's need to discover what parameters are available, to learn the spatial and temporal extend of the holdings, and to examine the character of the data (e.g, variability, gappiness, etc). These pieces of information help the end user decide if the data are fit for his/her purpose and to construct valid data requests. Note that on-line browse is a distinctly different activity than data analysis because it seeks to yield knowledge about the inventory and not about what the data mean. "Uniform" on-line browse is a service that takes advantage of the standardization of the data portal's data access points. Most portals represent station locations on a map. This is a view of the data inventory but these plots are rarely generated by pulling data through the standards-based services offered to the end users but through methods only available to the portal programmers. This work will present results of Uniform On-line browse tools developed within GCOOS-RA and their applicability to other RA portals.

  10. Evaluation of Instructional Systems RUPS and TABA. Final Report.

    Science.gov (United States)

    O'Neill, Phillip M.

    An investigation was conducted to determine the extent of dissemination of the Research Utilizing Problem Solving (Rups) and Development of Higher Level Thinking Abilities (TABA) instructional systems developed by the Northwest Regional Laboratory (NWREL), the degree of conformity between the RUPS and TABA systems as developed and as used in the…

  11. Airborne Electro-Optical Sensor Simulation System. Final Report.

    Science.gov (United States)

    Hayworth, Don

    The total system capability, including all the special purpose and general purpose hardware comprising the Airborne Electro-Optical Sensor Simulation (AEOSS) System, is described. The functional relationship between hardware portions is described together with interface to the software portion of the computer image generation. Supporting rationale…

  12. OLAP: A Fast, Easy, Affordable Executive Information System--Finally!

    Science.gov (United States)

    Stewart, Henry M.

    1995-01-01

    The University of Rochester's experience with online analytical processing (OLAP), part of its executive information system, is reported. The server, a multiuser, local area network (LAN)-based database loaded from legacy systems or a data warehouse, can rapidly manipulate and display data, and allows quick creation and changing of analytical…

  13. Economic incentives to wind systems commercialization. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Lotker, M.; Shaw, Jr, R. W.; Adolfson, W. F.; Bernardi, R. P.; Davidoff, P. H.; Eckhart, M. T.; Gunwaldsen, D. S.; Mettam, P. J.; Narayanan, P.; Sillin, J. O.

    1978-08-01

    This assessment of Economic Incentives to Wind Systems Commercialization is an analysis of the quantitative and qualitative impacts of a variety of Government funded economic incentives on Wind Energy Conversion Systems (WECS). The purpose of this study is to achieve better understanding of the relationship between implementation of specific economic incentives for WECS, and the factors surrounding WECS commercial introduction.

  14. Mirror fusion test facility magnet system. Final design report

    International Nuclear Information System (INIS)

    Henning, C.D.; Hodges, A.J.; VanSant, J.H.; Dalder, E.N.; Hinkle, R.E.; Horvath, J.A.; Scanlan, R.M.; Shimer, D.W.; Baldi, R.W.; Tatro, R.E.

    1980-01-01

    Information is given on each of the following topics: (1) magnet description, (2) superconducting manufacture, (3) mechanical behavior of conductor winding, (4) coil winding, (5) thermal analysis, (6) cryogenic system, (7) power supply system, (8) structural analysis, (9) structural finite element analysis refinement, (10) structural case fault analysis, and (11) structural metallurgy

  15. HVAC systems and nuclear plant safety. Final report, May 1992

    International Nuclear Information System (INIS)

    1992-05-01

    The primary objective of this study was to provide perspective on the overall risk impact of heating, ventilating, and air conditioning (HVAC) system problems. Industry experience with HVAC system problems is documented and analyzed. In addition, the results of 10 plant-specific probabilistic risk assessments (PRA) were reviewed to determine the contribution of HVAC systems to the risk of core damage. The PRAs included in this review cover a broad range of plant types and operating conditions. The review found that the impact of HVAC systems on risk is plant specific. These results exhibit a broad range of frequencies for HVAC contribution to risk, and the percentage of total core damage due to HVAC problems also had a wide variability. Plant-specific differences in design, environment, operation, and maintenance are the primary factors in determining the risk contribution of HVAC systems. (author)

  16. Developing maintainability for fusion power systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, H.S.; Mantz, H.C.; Curtis, C.T.; Buchheit, R.J.; Green, W.M.; Zuckerman, D.S.

    1979-11-01

    The overall purpose of the study is to identify design features of fusion power reactors which contribute to the achievement of high levels of maintainability. Previous phases evaluated several commercial tokamak reactor design concepts. This final phase compares the maintainability of a tandem mirror reactor (TMR) commercial conceptual design with the most maintainable tokamak concept selected from earlier work. A series of maintainability design guidelines and desirable TMR design features are defined. The effects of scheduled and unscheduled maintenance for most of the reactor subsystems are defined. The comparison of the TMR and tokamak reactor maintenance costs and availabilities show that both reactors have similar costs for scheduled maintenance at 19.4 and 20.8 million dollars annually and similar scheduled downtime availability impacts, achieving approximate availabilities of 79% at optimized maintenance intervals and cost of electricity.

  17. Developing maintainability for fusion power systems. Final report

    International Nuclear Information System (INIS)

    Zahn, H.S.; Mantz, H.C.; Curtis, C.T.; Buchheit, R.J.; Green, W.M.; Zuckerman, D.S.

    1979-11-01

    The overall purpose of the study is to identify design features of fusion power reactors which contribute to the achievement of high levels of maintainability. Previous phases evaluated several commercial tokamak reactor design concepts. This final phase compares the maintainability of a tandem mirror reactor (TMR) commercial conceptual design with the most maintainable tokamak concept selected from earlier work. A series of maintainability design guidelines and desirable TMR design features are defined. The effects of scheduled and unscheduled maintenance for most of the reactor subsystems are defined. The comparison of the TMR and tokamak reactor maintenance costs and availabilities show that both reactors have similar costs for scheduled maintenance at 19.4 and 20.8 million dollars annually and similar scheduled downtime availability impacts, achieving approximate availabilities of 79% at optimized maintenance intervals and cost of electricity

  18. System study of alternative waste management techniques: Final report

    International Nuclear Information System (INIS)

    1986-01-01

    This report summarizes the important results achieved in conjunction with the Research and Development Priority ''Alternative Waste Management Techniques'' sponsored by the Federal Ministry of Research and Technology from 1981 to 1984. The subject of these studies was solely ''direct disposal'' of spent fuel elements. For this purpose a reference concept was selected from a variety of possible processes and engineered in detailed form by firms in the nuclear industry. Those who worked on the engineering concepts consider this waste management method technically feasible. Several disposal casks have been fabricated. The basic licensability of direct disposal can be evaluated on the basis of the documentation developed by the companies. The direct disposal method was compared with the ''integrated waste management concept'' using reference fuel cycles with respect to the following criteria: radiological safety and nuclear material safeguards and, in addition, economic and energy-policy aspects. It was found that with respect to radiological safety, including the long-term safety of the final repository, there are no significant differences between the two fuel cycles with and without reprocessing. With respect to the nuclear material safeguards of a final repository containing spent fuel elements, there are still a number of unanswered questions. From an economic standpoint, direct disposal will be more economical in the foreseeable future than integrated waste management. Quantification of the effects of one or the other waste management method on the national economy is not necessarily possible. Reprocessing is supported primarily by technological and energy-policy considerations. On the basis of the results, the conclusion is reached that reprocessing should be pursued further, but that at the same time direct disposal should be developed to the point of practical maturity

  19. Portal monitor incorporating smart probes

    International Nuclear Information System (INIS)

    Bartos, D.; Constantin, F.; Guta, T.

    2003-01-01

    Portal monitors are intended for detection of radioactive and special nuclear materials in vehicles, pedestrians, luggage, as well as for prevention of illegal traffic of radioactive sources. Monitors provide audio and visual alarms when radioactive and/or special nuclear materials are detected. They can be recommended to officers of customs, border guard and emergency services, civil defense, fire brigades, police and military departments or nuclear research or energetic facilities. The portal monitor developed by us consists in a portal frame, which sustains five intelligent probes having long plastic scintillator (0.5 liters each). The probes communicate, by serial transmission, with a Central Unit constructed on the basis of the 80552 microcontroller. This one manages the handshake, calculates the background, establishes the measuring time, starts and stops each measurement and makes all the other decisions. Sound signals and an infrared sensor monitor the passing through the portal and the measuring procedure. For each measurement the result is displayed on a LCD device contaminated/uncontaminated; for the contaminated case a loud and long sound signal is also issued. An RS 232 serial interface is provided in order to further developments or custom made devices. As a result, the portal monitor detects 1 μ Ci 137 Cs, spread all over a human body, in a 20 μR/h gamma background for a measuring time of 1.5 or 10 seconds giving a 99% confidence factor. (authors)

  20. Nuclear Power Safety Reporting System. Final evaluation results

    International Nuclear Information System (INIS)

    Finlayson, F.C.; Newton, R.D.

    1986-02-01

    This document presents the results of a study conducted by the US Nuclear Regulatory Commission of an unobtrusive, voluntary, anonymous third-party managed, nonpunitive human factors data gathering system (the Nuclear power Safety Reporting System - NPSRS) for the nuclear electric power production industry. The data to be gathered by the NPSRS are intended for use in identifying and quantifying the factors that contribute to the occurrence of significant safety incidents involving humans in nuclear power plants. The NPSRS has been designed to encourage participation in the System through guarantees of reporter anonymity provided by a third-party organization that would be responsible for NPSRS management. As additional motivation to reporters for contributing data to the NPSRS, conditional waivers of NRC disciplinary action would be provided to individuals. These conditional waivers of immunity would apply to potential violations of NRC regulations that might be disclosed through reports submitted to the System about inadvertent, noncriminal incidents in nuclear plants. This document summarizes the overall results of the study of the NPSRS concept. In it, a functional description of the NPSRS is presented together with a review and assessment of potential problem areas that might be met if the System were implemented. Conclusions and recommendations resulting from the study are also presented. A companion volume (NUREG/CR-4133, Nuclear Power Safety Reporting System: Implementation and Operational Specifications'') presented in detail the elements, requirements, forms, and procedures for implementing and operating the System. 13 refs

  1. Intergovernmental Advanced Stationary PEM Fuel Cell System Demonstration Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Rich Chartrand

    2011-08-31

    A program to complete the design, construction and demonstration of a PEMFC system fuelled by Ethanol, LPG or NG for telecom applications was initiated in October 2007. Early in the program the economics for Ethanol were shown to be unfeasible and permission was given by DOE to focus on LPG only. The design and construction of a prototype unit was completed in Jun 2009 using commercially available PEM FC stack from Ballard Power Systems. During the course of testing, the high pressure drop of the stack was shown to be problematic in terms of control and stability of the reformer. Also, due to the power requirements for air compression the overall efficiency of the system was shown to be lower than a similar system using internally developed low pressure drop FC stack. In Q3 2009, the decision was made to change to the Plug power stack and a second prototype was built and tested. Overall net efficiency was shown to be 31.5% at 3 kW output. Total output of the system is 6 kW. Using the new stack hardware, material cost reduction of 63% was achieved over the previous Alpha design. During a November 2009 review meeting Plug Power proposed and was granted permission, to demonstrate the new, commercial version of Plug Power's telecom system at CERL. As this product was also being tested as part of a DOE Topic 7A program, this part of the program was transferred to the Topic 7A program. In Q32008, the scope of work of this program was expanded to include a National Grid demonstration project of a micro-CHP system using hightemperature PEM technology. The Gensys Blue system was cleared for unattended operation, grid connection, and power generation in Aug 2009 at Union College in NY state. The system continues to operate providing power and heat to Beuth House. The system is being continually evaluated and improvements to hardware and controls will be implemented as more is learned about the system's operation. The program is instrumental in improving the

  2. Automated personnel data base system specifications, Task V. Final report

    International Nuclear Information System (INIS)

    Bartley, H.J.; Bocast, A.K.; Deppner, F.O.; Harrison, O.J.; Kraas, I.W.

    1978-11-01

    The full title of this study is 'Development of Qualification Requirements, Training Programs, Career Plans, and Methodologies for Effective Management and Training of Inspection and Enforcement Personnel.' Task V required the development of an automated personnel data base system for NRC/IE. This system is identified as the NRC/IE Personnel, Assignment, Qualifications, and Training System (PAQTS). This Task V report provides the documentation for PAQTS including the Functional Requirements Document (FRD), the Data Requirements Document (DRD), the Hardware and Software Capabilities Assessment, and the Detailed Implementation Schedule. Specific recommendations to facilitate implementation of PAQTS are also included

  3. Laser fusion systems design study. Final technical report

    International Nuclear Information System (INIS)

    1975-06-01

    This study investigated: (1) the formulation and evaluation of an alignment system to accomplish pointing, focusing, centering and translation for the 20-arm SHIVA laser, (2) the formulation and evaluation of concepts for the correction of static phase distortions introduced by the accumulated optical elements in the laser chains, (3) the formulation and evaluation of concepts for the correction of optical path length differences between the arms of the SHIVA system, and (4) the conceptual design of appropriate control system hardware. (U.S.)

  4. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  5. Improved Controls for Fusion RF Systems. Final technical report

    International Nuclear Information System (INIS)

    Casey, Jeffrey A.

    2011-01-01

    We have addressed the specific requirements for the integrated systems controlling an array of klystrons used for Lower Hybrid Current Drive (LHCD). The immediate goal for our design was to modernize the transmitter protection system (TPS) for LHCD on the Alcator C-Mod tokamak at the MIT Plasma Science and Fusion Center (MIT-PSFC). Working with the Alcator C-Mod team, we have upgraded the design of these controls to retrofit for improvements in performance and safety, as well as to facilitate the upcoming expansion from 12 to 16 klystrons. The longer range goals to generalize the designs in such a way that they will be of benefit to other programs within the international fusion effort was met by designing a system which was flexible enough to address all the MIT system requirements, and modular enough to adapt to a large variety of other requirements with minimal reconfiguration

  6. Improved Controls for Fusion RF Systems. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Jeffrey A. [Rockfield Research Inc., Las Vegas, NV (United States)

    2011-11-08

    We have addressed the specific requirements for the integrated systems controlling an array of klystrons used for Lower Hybrid Current Drive (LHCD). The immediate goal for our design was to modernize the transmitter protection system (TPS) for LHCD on the Alcator C-Mod tokamak at the MIT Plasma Science and Fusion Center (MIT-PSFC). Working with the Alcator C-Mod team, we have upgraded the design of these controls to retrofit for improvements in performance and safety, as well as to facilitate the upcoming expansion from 12 to 16 klystrons. The longer range goals to generalize the designs in such a way that they will be of benefit to other programs within the international fusion effort was met by designing a system which was flexible enough to address all the MIT system requirements, and modular enough to adapt to a large variety of other requirements with minimal reconfiguration.

  7. Repair systems for deteriorated bridge piles : final report.

    Science.gov (United States)

    2017-04-01

    The objective of this research project is to develop a durable repair system for deteriorated steel bridge piles that : can be implemented without the need for dewatering. A rigorous survey of the relevant practice nationwide was : conducted to infor...

  8. Culvert information management system : demonstration project, final report, August 2009.

    Science.gov (United States)

    2009-08-01

    The overall objective of the research was to develop a pilot scale Culvert Information Management System (CIMS) that will : comply with both requirements stipulated by the Governmental Accounting Standards Board (GASB-34) and new federal : storm wate...

  9. Louisiana DOTD maintenance budget allocation system: final report.

    Science.gov (United States)

    2002-11-01

    This project developed a computer system to assist Louisiana Department of Transportation and Development (LA DOTD) maintenance managers in the preparation of zero-based, needs-driven annual budget plans for routine maintenance. This includes pavemen...

  10. Intelligent transportation systems business plan for Kentucky : final report.

    Science.gov (United States)

    2001-09-01

    This report presents a Business Plan for Intelligent Transportation Systems (ITS) in Kentucky. The purpose of the Business Plan is to define ITS projects that are planned for implementation from 2002 through 2007. The list of projects contained withi...

  11. Static Scale Conversion Weigh-In-Motion System; FINAL

    International Nuclear Information System (INIS)

    Beshears, D.L.

    2001-01-01

    In support of the Air Mobility Battle Lab (AMBL), the Defense Advanced Research Projects Agency (DARPA) Advanced Logistics Program and the U. S. Transportation Command (USTRANSCOM), the ultimate objective of this project is to develop and demonstrate a full-scale prototype static scale conversion weigh-in-motion/Profilometry (SSC-WIM/P) system to measure and record dimensional and weight information for the Department of Defense (DoD) equipment and cargo. The Oak Ridge National Laboratory (ORNL), along with the AMBL, and Intercomp, Inc. have developed a long-range plan for developing a dual-use system which can be used as a standard static scale or an accurate weigh-in-motion system. AMBL will work to define requirements for additional activities with U.S. Transportation Command, Air Mobility Command, and the Joint Warfighting Battle Lab for both the SSC-WIM/P and a portable Weigh-in-Motion System for individual units. The funding goal is to fully fund the development of two prototype test articles (a SSC-WIM kit, and a laser profilometer) and have at least one fully operational system by the early 2002 timeframe. The objective of this portion of the project will be to develop a SSC-WIM system, which at a later date can be fully integrated with a profilometry system; to fully characterize DOD wheeled vehicles and cargo (individual axle weights, total vehicle weight, center of balance, height, width and length measurements). The program will be completed in phases with the initial AMBL/DARPA funding being used to initiate the efforts while AMBL/USTC obtains funding to complete the first generation system effort. At the completion of an initial effort, the interface hardware and the data acquisition/analysis hardware will be developed, fabricated, and system principles and basic functionality evaluated, tested, and demonstrated. Additional funding, when made available, will allow the successful completion of a first generation prototype system. This effort will be

  12. Solid oxide fuel cell systems development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-12-15

    The main objective in this project has been to develop a generic and dynamic tool for SOFC systems simulation and development. Developing integrated fuel cell systems is very expensive and therefore having the right tools to reduce the development cost and time to market for products becomes an important feature. The tools developed in this project cover a wide range of needs in Dantherm Power, R and D, and can be divided into 3 categories: 1. Component selection modeling; to define component specification requirements and selection of suppliers. 2. Application simulation model built from scratch, which can simulate the interface between customer demand and system output and show operation behavior for different control settings. 3. System operation strategy optimization with respect to operation cost and customer benefits. a. Allows to see how system size, in terms of electricity and heat output, and operation strategy influences a specific business case. b. Gives a clear overview of how a different property, in the system, affects the economics (e.g. lifetime, electrical and thermal efficiency, fuel cost sensitivity, country of deployment etc.). The main idea behind the structure of the tool being separated into 3 layers is to be able to service different requirements, from changing stakeholders. One of the major findings in this project has been related to thermal integration between the existing installation in a private household and the fuel cell system. For a normal family requiring 4500 kWh of electricity a year, along with the possibility of only running the system during the heating season (winter), the heat storage demand is only 210kWh of heat with an approximate value of Dkr 160,- in extra gas consumption. In this case, it would be much more cost effective to dump the heat, in the house, and save the expense of adding heat storage to the system. This operation strategy is only valid in Denmark for the time being, since the feed-In-Tariff allows for a

  13. Solar heating system installed at Jackson, Tennessee. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-10-01

    The solar energy heating system installed at the Coca-Cola Bottling Works in Jackson, Tennessee is described. The system consists of 9480 square feet of Owens-Illinois evacuated tubular solar collectors with attached specular cylindrical reflectors and will provide space heating for the 70,000 square foot production building in the winter, and hot water for the bottle washing equipment the remainder of the year. Component specifications and engineering drawings are included. (WHK)

  14. Center for Advanced Biofuel Systems (CABS) Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Kutchan, Toni M. [Donald Danforth Plant Science Center, St. Louis, MO (United States)

    2015-12-02

    One of the great challenges facing current and future generations is how to meet growing energy demands in an environmentally sustainable manner. Renewable energy sources, including wind, geothermal, solar, hydroelectric, and biofuel energy systems, are rapidly being developed as sustainable alternatives to fossil fuels. Biofuels are particularly attractive to the U.S., given its vast agricultural resources. The first generation of biofuel systems was based on fermentation of sugars to produce ethanol, typically from food crops. Subsequent generations of biofuel systems, including those included in the CABS project, will build upon the experiences learned from those early research results and will have improved production efficiencies, reduced environmental impacts and decreased reliance on food crops. Thermodynamic models predict that the next generations of biofuel systems will yield three- to five-fold more recoverable energy products. To address the technological challenges necessary to develop enhanced biofuel systems, greater understanding of the non-equilibrium processes involved in solar energy conversion and the channeling of reduced carbon into biofuel products must be developed. The objective of the proposed Center for Advanced Biofuel Systems (CABS) was to increase the thermodynamic and kinetic efficiency of select plant- and algal-based fuel production systems using rational metabolic engineering approaches grounded in modern systems biology. The overall strategy was to increase the efficiency of solar energy conversion into oils and other specialty biofuel components by channeling metabolic flux toward products using advanced catalysts and sensible design:1) employing novel protein catalysts that increase the thermodynamic and kinetic efficiencies of photosynthesis and oil biosynthesis; 2) engineering metabolic networks to enhance acetyl-CoA production and its channeling towards lipid synthesis; and 3) engineering new metabolic networks for the

  15. Final Report for the Virtual Reliability Realization System LDRD

    Energy Technology Data Exchange (ETDEWEB)

    DELLIN, THEODORE A.; HENDERSON, CHRISTOPHER L.; O' TOOLE, EDWARD J.

    2000-12-01

    Current approaches to reliability are not adequate to keep pace with the need for faster, better and cheaper products and systems. This is especially true in high consequence of failure applications. The original proposal for the LDRD was to look at this challenge and see if there was a new paradigm that could make reliability predictions, along with a quantitative estimate of the risk in that prediction, in a way that was faster, better and cheaper. Such an approach would be based on the underlying science models that are the backbone of reliability predictions. The new paradigm would be implemented in two software tools: the Virtual Reliability Realization System (VRRS) and the Reliability Expert System (REX). The three-year LDRD was funded at a reduced level for the first year ($120K vs. $250K) and not renewed. Because of the reduced funding, we concentrated on the initial development of the expertise system. We developed an interactive semiconductor calculation tool needed for reliability analyses. We also were able to generate a basic functional system using Microsoft Siteserver Commerce Edition and Microsoft Sequel Server. The base system has the capability to store Office documents from multiple authors, and has the ability to track and charge for usage. The full outline of the knowledge model has been incorporated as well as examples of various types of content.

  16. Project on Alternative Systems Study - PASS. Final report

    International Nuclear Information System (INIS)

    1992-10-01

    Alternative repository systems for deep disposal of spent fuel and different types of canisters are studied regarding technical aspects in Project on Alternative System Study (PASS). The objective is to present a ranking of repository systems as well as of canister types for each system. The studies and compared systems are: KBS-3, Medium Long Tunnels (MLH), Long tunnels (VLH) and Deep Boreholes (VDH). For KBS-3 and MLH five canister types are compared (copper/steel, copper/lead, copper (HIP), steel/lead and steel), for VLH two types (copper/steel and steel), and for VDH three types (titanium/concrete with non-consolidated fuel assemblies, titanium/concrete with consolidated assemblies and copper (HIP) with non-consolidated assemblies). The comparison is separated into three sub-comparisons (Technology, Long-term performance and safety, and Costs), which eventually are merged into one ranking. With respect to canister alternatives the result is that the copper/steel canister is ranked first for KBS-3, MLH and VLH, while the titanium/concrete canister is ranked first for VDH (non-consolidated as well as consolidated assemblies. With these canister alternatives the merged ranking of repository systems results in placing KBS-3 slightly in front of MLH. VLH comes thereafter and VDH last. (32 refs.)

  17. Heart/liver ratios and portal vein pressure used in early cirrhosis diagnosis

    International Nuclear Information System (INIS)

    He Jingxiang; Li Wenfan; Liu Chun; Yang Peng; Chen Ming; Wang Hong

    2001-01-01

    Objective: To find a method which not only can comprehensively evaluate the rise of portal pressure, opening and establishment of portal collateral circulation, portal-systemic shunting, and liver and spleen functions in cirrhosis, but also aid the differential diagnosis of early and established cirrhosis. Methods: Heart/liver count (H/L) ratios were obtained at different times after per-rectal administration of 99m Tc-MIBI. Portal venous pressures at different times were calculated using a previously documented formula. The relationship between portal venous pressure and cirrhosis, including its pathological process, was then evaluated. Results: There was obvious discrepancy (t=2.810; p<0.05) in 90-150 minutes portal venous pressures between normal and late hepatitis groups; there was also obvious difference (t=2.348, p<0.05) in portal venous pressures between the cirrhosis group and other groups. The portal venous pressure of early cirrhosis group was also significantly different (t=2.167, p<0.05) from other groups and it was situated between those of normal, and hepatitis and cirrhosis groups. There was obvious diversity (t=2.287, p<0.05) in Child-Pugh classification levels in the late imaging phase. There was positive correlation between calculated portal venous pressure and H/L ratio (r=0.487, p<0.01). Conclusion: Using temporal portal venous recirculation imaging, an early H/L ratio of ≥0.65 and formula-calculated portal venous pressure of ≥1.9 kPa or a portal-systemic venous pressure difference of ≥1.5 kPa indicate cirrhosis; H/L ratio between 0.32 and 0.64 or portal venous pressure between 1.03 to 1.89 kPa suggest early cirrhosis. Our study showed that H/L ratios at specific times and computed portal vein pressure might be important in the diagnosis of hepatitis, impaired hepatic function caused by cirrhosis, portal-systemic shunting, and portal venous recirculation. It is a simple, sensitive, reliable, and non-invasive method, which can be helpful in

  18. Smart Infrared Inspection System Field Operational Test Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Siekmann, Adam [ORNL; Capps, Gary J [ORNL; Franzese, Oscar [ORNL; Lascurain, Mary Beth [ORNL

    2011-06-01

    The Smart InfraRed Inspection System (SIRIS) is a tool designed to assist inspectors in determining which vehicles passing through the SIRIS system are in need of further inspection by measuring the thermal data from the wheel components. As a vehicle enters the system, infrared cameras on the road measure temperatures of the brakes, tires, and wheel bearings on both wheel ends of commercial motor vehicles (CMVs) in motion. This thermal data is then presented to enforcement personal inside of the inspection station on a user friendly interface. Vehicles that are suspected to have a violation are automatically alerted to the enforcement staff. The main goal of the SIRIS field operational test (FOT) was to collect data to evaluate the performance of the prototype system and determine the viability of such a system being used for commercial motor vehicle enforcement. From March 2010 to September 2010, ORNL facilitated the SIRIS FOT at the Greene County Inspection Station (IS) in Greeneville, Tennessee. During the course of the FOT, 413 CMVs were given a North American Standard (NAS) Level-1 inspection. Of those 413 CMVs, 384 were subjected to a SIRIS screening. A total of 36 (9.38%) of the vehicles were flagged by SIRIS as having one or more thermal issues; with brakes issues making up 33 (91.67%) of those. Of the 36 vehicles flagged as having thermal issues, 31 (86.11%) were found to have a violation and 30 (83.33%) of those vehicles were placed out-of-service (OOS). Overall the enforcement personnel who have used SIRIS for screening purposes have had positive feedback on the potential of SIRIS. With improvements in detection algorithms and stability, the system will be beneficial to the CMV enforcement community and increase overall trooper productivity by accurately identifying a higher percentage of CMVs to be placed OOS with minimal error. No future evaluation of SIRIS has been deemed necessary and specifications for a production system will soon be drafted.

  19. Green Lighting. Energy-efficient integrated lighting systems - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Linhart, F.; Scartezzini, J.-L.

    2009-10-15

    The objective of the Green Lighting project was to develop a High Performance Integrated Lighting System, based on advanced technologies for day- and electric lighting, achieving a Lighting Power Density (LPD) that does not exceed 3 W/m{sup 2}. The project has revealed that Anidolic Daylighting Systems (ADS) are an ideal basis for High Performance Integrated Lighting Systems. Not only are they able to provide adequate illumination (i.e. sufficiently high illuminance) in office rooms during large fractions of normal office hours, under various sky conditions and over the entire year, but they are also highly appreciated by office occupants at the condition that glare control mechanisms are available. Complementary electric lighting is, however, still necessary to back up the ADS at times when there is insufficient daylight flux available. It was shown during this project, that the most interesting trade-offs between energy-efficiency and visual comfort are obtained by using a combination of ceiling-mounted directly emitting luminaires with very high optical efficiencies for ambient lighting and portable desk lamps for temporary task lighting. The most appropriate lamps for the ceiling-mounted luminaires are currently highly efficient fluorescent tubes, but white LED tubes can be considered a realistic option for the future. The most suitable light sources for desk lamps for temporary task lighting are Compact Fluorescent Lamps (CFLs) and white LED light bulbs. Based on the above-mentioned technologies, a High Performance Integrated Lighting System with a very low LPD has been developed over the last three years. The system has been set up in an office room of the LESO solar experimental building located on the EPFL campus; it has been tested intensively during a Post-Occupancy Evaluation (POE) study involving twenty human subjects. This study has revealed that the subjects' performance and subjective visual comfort was improved by the new system, compared to

  20. The Higgs portal above threshold

    Energy Technology Data Exchange (ETDEWEB)

    Craig, Nathaniel [Department of Physics, University of California,Santa Barbara, CA 93106 (United States); Lou, Hou Keong [Department of Physics, Princeton University,Princeton, NJ 08540 (United States); McCullough, Matthew [Theory Division, CERN,1211 Geneva 23 (Switzerland); Thalapillil, Arun [Department of Physics and Astronomy, Rutgers University,Piscataway, NJ 08854 (United States)

    2016-02-18

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  1. The Higgs portal above threshold

    International Nuclear Information System (INIS)

    Craig, Nathaniel; Lou, Hou Keong; McCullough, Matthew; Thalapillil, Arun

    2016-01-01

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  2. Systems study 'Alternative Entsorgung'. Final report. Technical annex 7

    International Nuclear Information System (INIS)

    Engelmann, H.J.

    1984-10-01

    A radiation protection concept was worked out for final storage of spent fuel elements. It contains the areas of instrumentation and equipment with the necessary devices and measuring equipment for monitoring emission and the room air, personnel dosimetry, measuring contamination, local dose rate measurements and division into radiation protection areas. The barrel incoming inspection is described. The work for determining the radiological load of the operating staff and the environment for correct and incorrect operation is also described. The radiological load of the operating staff for correct operation was determined in the form of the collective dose with dose factors in accordance with ICRP and individual doses according to Radiation Protection Ordinance. The collective dose is 0.28 pers. Sv/a and the maximum individual dose remains below 1.0 E-2 Sv/a. The individual doses determined remain below the permitted limits of Radiation Protection Ordinance. In the context of accident analysis, it was found that no accidents occur, which load the operating staff radiologically above the permitted limits of the Radiation Protection Ordinance. A probability consideration of accidents shows that the accident risk of the operating staff is several orders of magnitude below that of the normal operating risk. (orig./HP) [de

  3. Automatic verification of step-and-shoot IMRT field segments using portal imaging

    International Nuclear Information System (INIS)

    Woo, M.K.; Lightstone, A.W.; Shan, G.; Kumaraswamy, L.; Li, Y.

    2003-01-01

    In step-and-shoot IMRT, many individual beam segments are delivered. These segments are generated by the IMRT treatment planning system and subsequently transmitted electronically through computer hardware and software modules before they are finally delivered. Hence, an independent system that monitors the actual field shape during treatment delivery is an added level of quality assurance in this complicated process. In this paper we describe the development and testing of such a system. The system verifies the field shape by comparing the radiation field detected by the built-in portal imaging system on the linac to the actual field shape planned on the treatment planning system. The comparison is based on a software algorithm that detects the leaf edge positions of the radiation field on the portal image and compares that to the calculated positions. The process is fully automated and requires minimal intervention of the radiation therapists. The system has been tested with actual clinical plan sequences and was able to alert the operator of incorrect settings in real time

  4. Occupancy-counter-based control system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, G.; Hoagland, L. C.; Bowman, J. K.

    1979-07-01

    Excessive mechanical ventilation of commercial and institutional buildings can result in significant waste of energy required for space heating and cooling. Ventilation rates are typically set to satisfy building design occupancy levels, in accordance with local codes, even though the building may seldom or never experience design occupancy. A method of eliminating this waste to utilize an occupancy-based ventilation control system wherein a counting device records people entering and leaving the building, to maintain a continuous record of people inventory, and to regulate mechanical ventilation control dampers to supply only that amount of ventilation air required for current occupancy levels is described. A device of this type was installed and tested in a department store in Framingham, Massachusetts and fully instrumented and operated over a 14 month period. Test results on energy usage were correlated with weather severity in order to determine the savings resulting from use of the control system. This system provided a savings of 33% in gas usage during the winter period and a savings of 23% in electricity usage during the summer period. These savings would return the installed cost of the control system in about 1 1/2 years. Projections of the performance of this system in other climatic regions (Chicago, Los Angeles, Kansas City, Miami, Minneapolis) are also presented illustrating payback periods ranging from 1/3 year in Miami to 2 2/3 years in Los Angeles. Complete details of the occupancy based ventilation control system, the test site instrumentation and data gathering procedure, the test results and their interpretation are given. (MCW)

  5. Analysis of batteries for use in photovoltaic systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Podder, A; Kapner, M

    1981-02-01

    An evaluation of 11 types of secondary batteries for energy storage in photovoltaic electric power systems is given. The evaluation was based on six specific application scenarios which were selected to represent the diverse requirements of various photovoltaic systems. Electrical load characteristics and solar insulation data were first obtained for each application scenario. A computer-based simulation program, SOLSIM, was then developed to determine optimal sizes for battery, solar array, and power conditioning systems. Projected service lives and battery costs were used to estimate life-cycle costs for each candidate battery type. The evaluation considered battery life-cycle cost, safety and health effects associated with battery operation, and reliability/maintainability. The 11 battery types were: lead-acid, nickel-zinc, nickel-iron, nickel-hydrogen, lithium-iron sulfide, calcium-iron sulfide, sodium-sulfur, zinc-chlorine, zinc-bromine, Redox, and zinc-ferricyanide. The six application scenarios were: (1) a single-family house in Denver, Colorado (photovoltaic system connected to the utility line); (2) a remote village in equatorial Africa (stand-alone power system); (3) a dairy farm in Howard County, Maryland (onsite generator for backup power); (4) a 50,000 square foot office building in Washington, DC (onsite generator backup); (5) a community in central Arizona with a population of 10,000 (battery to be used for dedicated energy storage for a utility grid-connected photovoltaic power plant); and (6) a military field telephone office with a constant 300 W load (trailer-mounted auxiliary generator backup). Recommendations for a research and development program on battery energy storage for photovoltaic applications are given, and a discussion of electrical interfacing problems for utility line-connected photovoltaic power systems is included. (WHK)

  6. ADVANCED TURBINE SYSTEM CONCEPTUAL DESIGN AND PRODUCT DEVELOPMENT - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht H. Mayer

    2000-07-15

    Asea Brown Boveri (ABB) has completed its technology based program. The results developed under Work Breakdown Structure (WBS) 8, concentrated on technology development and demonstration have been partially implemented in newer turbine designs. A significant improvement in heat rate and power output has been demonstrated. ABB will use the knowledge gained to further improve the efficiency of its Advanced Cycle System, which has been developed and introduced into the marked out side ABB's Advanced Turbine System (ATS) activities. The technology will lead to a power plant design that meets the ATS performance goals of over 60% plant efficiency, decreased electricity costs to consumers and lowest emissions.

  7. Design and synthesis of reactive separation systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Doherty, M.F.

    1992-12-31

    During the last decade there has been a rapid upturn in interest in reactive distillation. The chemical process industry recognizes the favorable economics of carrying out reaction simultaneously with distillation for certain classes of reacting systems, and many new processes have been built based on this technology. Interest is also increasing by academics and software vendors. Systematic design methods for reactive distillation systems have only recently begun to emerge. In this report we survey the available design techniques and point out the contributions made by our group at the University of Massachusetts.

  8. ADVANCED TURBINE SYSTEM CONCEPTUAL DESIGN AND PRODUCT DEVELOPMENT; FINAL

    International Nuclear Information System (INIS)

    Albrecht H. Mayer

    2000-01-01

    Asea Brown Boveri (ABB) has completed its technology based program. The results developed under Work Breakdown Structure (WBS) 8, concentrated on technology development and demonstration have been partially implemented in newer turbine designs. A significant improvement in heat rate and power output has been demonstrated. ABB will use the knowledge gained to further improve the efficiency of its Advanced Cycle System, which has been developed and introduced into the marked out side ABB's Advanced Turbine System (ATS) activities. The technology will lead to a power plant design that meets the ATS performance goals of over 60% plant efficiency, decreased electricity costs to consumers and lowest emissions

  9. Operations-oriented performance measures for freeway management systems : final report.

    Science.gov (United States)

    2008-12-01

    This report describes the second and final year activities of the project titled Using Operations-Oriented Performance Measures to Support Freeway Management Systems. Work activities included developing a prototype system architecture for testi...

  10. The Workplace Literacy System Project (WLS). Final Performance Report.

    Science.gov (United States)

    Poulton, Bruce R.

    The Workplace Literacy System Project (WLS) prepared interactive CD-ROM discs containing about 50 hours of instruction and drill in basic skills presented within the context of the textile/apparel manufacturing industry. The project was conducted at a Sara Lee knit products plant in North Carolina. During the project, literacy task analyses were…

  11. Schedule for Rating Disabilities; the Endocrine System. Final rule.

    Science.gov (United States)

    2017-11-02

    This document amends the Department of Veterans Affairs (VA) Schedule for Rating Disabilities (VASRD) by revising the portion of the Schedule that addresses endocrine conditions and disorders of the endocrine system. The effect of this action is to ensure that the VASRD uses current medical terminology and to provide detailed and updated criteria for evaluation of endocrine disorders.

  12. Safeguards systems concepts for nuclear material transportation. Final report

    International Nuclear Information System (INIS)

    Baldonado, O.C.; Kevany, M.; Rodney, D.; Pitts, D.; Mazur, M.

    1977-09-01

    The report describes the development of system concepts for the safeguarding of special strategic nuclear materials (SNM) against malevolent adversary action during the interfacility transport of the SNM. The methodology used includes techniques for defining, classifying, and analyzing adversary action sequences; defining safeguards system components; assessing the vulnerability of various safeguards systems and their component parts to the potential adversary action sequences, and conceptualizing system design requirements. The method of analysis is based primarily on a comparison of adversary actions with safeguards measures, to estimate vulnerability. Because of the paucity of the data available for assessing vulnerability, the Delphi approach was used to generate data: values were estimated in a structured exercise by a panel of experts in the safeguards and terrorist fields. It is concluded that the probability of successful attack against a truck/escort convoy manned by well-trained, well-armed personnel is low enough to discourage all but the strongest adversaries. Secrecy of operations and careful screening of personnel are very important. No reliance should be placed on current capabilities of local law enforcement agencies. The recommendation of the study is the use of road transport in the near future and air transport at a later time when the number of shipments reaches a level to justify it, and when present safety problems are resolved

  13. Design analysis of supplemental heating systems. Final report

    International Nuclear Information System (INIS)

    1981-09-01

    The first objective of the study was to formulate an R and D plan for tokamak supplemental heating based upon an evaluation and the potential of each heating technique. The second objective was to develop conceptual designs for reactor level heating systems. The two techniques selected for the second studies were icrh and negative beams

  14. Communications and control for electric power systems: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, H.

    1998-04-01

    This report is a summary of some of the work done on the Communications and Control project, with particular emphasis on the achievements during the years 1986--1996. During those years, the project moved away from concern with dispersed storage and generation and its impact on power system operation (the team was responsible for studies in this area, and for making a power system simulator that included DSG), and became involved in more concrete work aimed at applying high-tech solutions to problems of power system communications and control. This report covers work done at JPL on the following topics: (1) the measurement of electric and magnetic fields, both ac and dc; (2) the use of optical power to supply low-power electronics; (3) the design of a fault-tolerant communication system designed for distribution automation; and (4) a digital phase locked loop that allows the use of low-power transmitting electronics to recreate a good-quality signal at the receiver. In a report of this kind, only the results and highlights of the work are described.

  15. Survey of system responsibility in the Nordic countries. Final report

    International Nuclear Information System (INIS)

    2005-02-01

    In September 2004 the Nordic Council of Ministers asked Nordel to perform some tasks and present the results to the Council on 1 March 2005. One of the tasks is to survey how system responsibility is defined and executed in the different Nordic countries. According to the Nordic Council of Ministers, the survey shall illuminate similarities and differences between the countries and assess the reasons for the differences. Nordel is asked to present a joint view system responsibility in the Nordic countries. Among other things, the responsibility for the system operators and the participants in the market shall be defined. The definition shall also include the distribution of costs between costs for network business and costs for business in competition. This shall be done in a way that creates a common platform for the further harmonisation work and continuous positive development of the Nordic electricity market. It is also important to identify the need for changes in e.g. legislation and guidelines in the different countries as a consequence of an implementation of a common definition in the Nordic countries. Areas to be included in the task are among others, balance settlement, security of supply, congestion management and system services. (BA)

  16. Safe Active Scanning for Energy Delivery Systems Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Helms, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Salazar, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Scheibel, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Engels, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reiger, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-30

    The Department of Energy’s Cybersecurity for Energy Delivery Systems Program has funded Safe(r) Active Scanning for Energy Delivery Systems, led by Lawrence Livermore National Laboratory, to investigate and analyze the impacts of active scanning in the operational environment of energy delivery systems. In collaboration with Pacific Northwest National Laboratory and Idaho National Laboratory, active scans across three testbeds including 38 devices were performed. This report gives a summary of the initial literature survey performed on the SASEDS project as well as industry partner interview summaries and main findings from Phase 1 of the project. Additionally, the report goes into the details of scanning techniques, methodologies for testing, testbed descriptions, and scanning results, with appendices to elaborate on the specific scans that were performed. As a result of testing, a single device out of 38 exhibited problems when actively scanned, and a reboot was required to fix it. This single failure indicates that active scanning is not likely to have a detrimental effect on the safety and resilience of energy delivery systems. We provide a path forward for future research that could enable wide adoption of active scanning and lead utilities to incorporate active scanning as part of their default network security plans to discover and rectify rogue devices, adversaries, and services that may be on the network. This increased network visibility will allow operational technology cybersecurity practitioners to improve their situational awareness of networks and their vulnerabilities.

  17. Final evaluation of advanced and current leak detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Carlson, R.; Brewer, W.; Lanham, R.

    1989-01-01

    This report presents the results of a study to evaluate the adequacy of leak detection systems in light water reactors. The sources of numerous reported leaks and methods of detection have been documented. Research to advance the state of the art of acoustic leak detection is presented, and procedures for implementation are discussed

  18. Library Information System Time-Sharing (LISTS) Project. Final Report.

    Science.gov (United States)

    Black, Donald V.

    The Library Information System Time-Sharing (LISTS) experiment was based on three innovations in data processing technology: (1) the advent of computer time-sharing on third-generation machines, (2) the development of general-purpose file-management software and (3) the introduction of large, library-oriented data bases. The main body of the…

  19. Is There a Separate Visual Iconic Memory System? Final Report.

    Science.gov (United States)

    Levie, W. Howard; Levie, Diane D.

    The purpose of these studies was to provide evidence to support either the dual-coding hypothesis or the single-system hypothesis of human memory. In one experiment, college subjects were shown a mixed series of words and pictures either while simultaneously engaged in shadowing (repeating aloud) a prose passage presented via earphones or while…

  20. Automated Energy Distribution and Reliability System (AEDR): Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Buche, D. L.

    2008-07-01

    This report describes Northern Indiana Public Service Co. project efforts to develop an automated energy distribution and reliability system. The purpose of this project was to implement a database-driven GIS solution that would manage all of the company's gas, electric, and landbase objects.

  1. Portal hyperflow in patients with hepatosplenic mansonic schistosomiasis Hiperfluxo portal na forma hepatosplênica da esquistossomose mansônica

    Directory of Open Access Journals (Sweden)

    Roberto de Cleva

    2004-02-01

    Full Text Available PURPOSE: The purpose of this study was to assess portal hemodynamics in patients with portal hypertension due to hepatosplenic schistosomiasis as well as to assess the contribution of splanchnic hyperflow to the pathophysiology of the portal hypertension. METHODS: Sixteen patients with schistosomal portal hypertension and previous history of upper digestive bleeding due to esophageal varices rupture underwent elective esophagogastric devascularization and splenectomy and were prospectively studied. All patients underwent intraoperative invasive hemodynamic portal monitoring with a 4F-thermodilution catheter. The intraoperative portal hemodynamic assessment was conducted after laparotomy (initial and after esophagogastric devascularization (final. RESULTS: The initial portal pressure was elevated (mean 28.5 ± 4.5 mm Hg, and a significant drop of 25% was observed at the end of the surgery (21.9 ± 4.9 mm Hg. The initial portal flow was elevated (mean 1766.9 ± 686.6 mL/min. A significant fall (42% occurred at the end of the surgical procedure (1025.62 ± 338.7 mL/min. Fourteen patients (87.5% presented a portal flow of more than 1200 mL/min, and in 5 cases, values greater than 2000 mL/min were observed. CONCLUSIONS: Esophagogastric devascularization and splenectomy promote a significant reduction of the elevated portal pressure and flow in schistosomal portal hypertension. These data favor the hypothesis of portal hyperflow in the physiopathology of portal hypertension of schistosomiasis.OBJETIVOS: o objetivo do presente estudo é estudar a hemodinâmica portal em pacientes com hipertensão portal secundária a forma hepatoesplênica da esquistossomose e avaliar a contribuição do hiperfluxo esplênico na sua fisiopatologia CASUÍSTICA E MÉTODOS: Foram estudados prospectivamente 16 pacientes portadores de hipertensão portal secundária à forma hepatoesplênica da esquistossomose mansônica com indicação de tratamento cirúrgico. Todos foram

  2. 29 CFR 785.24 - Principles noted in Portal-to-Portal Bulletin.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Principles noted in Portal-to-Portal Bulletin. 785.24 Section 785.24 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR... of Principles Preparatory and Concluding Activities § 785.24 Principles noted in Portal-to-Portal...

  3. Racial/ethnic variation in devices used to access patient portals.

    Science.gov (United States)

    Chang, Eva; Blondon, Katherine; Lyles, Courtney R; Jordan, Luesa; Ralston, James D

    2018-01-01

    We examined racial/ethnic variation in the devices used by patients to access medical records through an online patient portal. Retrospective, cross-sectional analysis. Using data from 318,700 adults enrolled in an integrated delivery system between December 2012 and November 2013, we examined: 1) online patient portal use that directly engages the electronic health record and 2) portal use over desktops/laptops only, mobile devices only, or both device types. The primary covariate was race/ethnicity (non-Hispanic white, black, Hispanic, and Asian). Other covariates included age, sex, primary language, and neighborhood-level income and education. Portal use and devices used were assessed with multiple and multinomial logistic models, respectively. From December 2012 to November 2013, 56% of enrollees used the patient portal. Of these portal users, 62% used desktops/laptops only, 6% used mobile devices only, and 32% used both desktops/laptops and mobile devices. Black, Hispanic, and Asian enrollees had significantly lower odds of portal use than whites. Black and Hispanic portal users also were significantly more likely to use mobile devices only (relative risk ratio, 1.73 and 1.44, respectively) and both device types (1.21 and 1.07, respectively) than desktops/laptops only compared with whites. Although racial/ethnic minority enrollees were less likely to access the online patient portal overall, a greater proportion of black and Hispanic users accessed the patient portal with mobile devices than did non-Hispanic white users. The rapid spread of mobile devices among racial/ethnic minorities may help reduce variation in online patient portal use. Mobile device use may represent an opportunity for healthcare organizations to further engage black and Hispanic enrollees in online patient portal use.

  4. Hemodynamic evaluation of the right portal vein in healthy dogs of different body weights

    Directory of Open Access Journals (Sweden)

    de Almeida Mariana F

    2010-05-01

    Full Text Available Abstract Background Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights. Methods Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography. Results In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values. Conclusion Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.

  5. Design analysis of supplemental heating systems. Final report

    International Nuclear Information System (INIS)

    1981-09-01

    The main emphasis of this study is to formulate R and D program priority for the future development of the heating techniques. A secondary emphasis is to improve the present state of knowledge of reactor heating systems. The technique used to determine R and D program priority was to evaluate each technique against a set of selection criteria. The selection criteria were divided into two categories. The first category contains the criteria that are normally used to evaluate the potential of any idea to proceed into hardware development; the status of the theory; the status of the technology; system efficiency; and cost. The second category contains the criteria that have important implications for reactor level devices: susceptibility to radiation, maintainability; and critical real estate requirements

  6. Standard review plan for dry cask storage systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-01-01

    The Standard Review Plan (SRP) For Dry Cask Storage Systems provides guidance to the Nuclear Regulatory Commission staff in the Spent Fuel Project Office for performing safety reviews of dry cask storage systems. The SRP is intended to ensure the quality and uniformity of the staff reviews, present a basis for the review scope, and clarification of the regulatory requirements. Part 72, Subpart B generally specifies the information needed in a license application for the independent storage of spent nuclear fuel and high level radioactive waste. Regulatory Guide 3.61 {open_quotes}Standard Format and Content for a Topical Safety Analysis Report for a Spent Fuel Dry Storage Cask{close_quotes} contains an outline of the specific information required by the staff. The SRP is divided into 14 sections which reflect the standard application format. Regulatory requirements, staff positions, industry codes and standards, acceptance criteria, and other information are discussed.

  7. Standard review plan for dry cask storage systems. Final report

    International Nuclear Information System (INIS)

    1997-01-01

    The Standard Review Plan (SRP) For Dry Cask Storage Systems provides guidance to the Nuclear Regulatory Commission staff in the Spent Fuel Project Office for performing safety reviews of dry cask storage systems. The SRP is intended to ensure the quality and uniformity of the staff reviews, present a basis for the review scope, and clarification of the regulatory requirements. Part 72, Subpart B generally specifies the information needed in a license application for the independent storage of spent nuclear fuel and high level radioactive waste. Regulatory Guide 3.61 open-quotes Standard Format and Content for a Topical Safety Analysis Report for a Spent Fuel Dry Storage Caskclose quotes contains an outline of the specific information required by the staff. The SRP is divided into 14 sections which reflect the standard application format. Regulatory requirements, staff positions, industry codes and standards, acceptance criteria, and other information are discussed

  8. Fundamental research of decision support systems: Final report

    International Nuclear Information System (INIS)

    Kurstedt, H.A. Jr.

    1986-01-01

    Through an iterative application of Decision Support Systems (DSS) apparatus and evolution of DSS concepts, we redefined DSS from a systems perspective. By focusing on successful DSS and the definition of success for the newly-defined DSS, we generated a paradigm for understanding, applying, and improving DSS. The significance of the research is that we now: (1) understand the various roles management tools play within the new DSS concept; (2) recognize the need for characterizing the domain of responsibility of a manager to obtain a successful DSS; and (3) have learned special characteristics of government agencies like Nuclear Materials (NM) to identify what features of the new DSS concept can be expected to improve performance

  9. From EGEE Operations Portal towards EGI Operations Portal

    Science.gov (United States)

    Cordier, Hélène; L'Orphelin, Cyril; Reynaud, Sylvain; Lequeux, Olivier; Loikkanen, Sinikka; Veyre, Pierre

    Grid operators in EGEE have been using a dedicated dashboard as their central operational tool, stable and scalable for the last 5 years despite continuous upgrade from specifications by users, monitoring tools or data providers. In EGEE-III, recent regionalisation of operations led the Operations Portal developers to conceive a standalone instance of this tool. We will see how the dashboard reorganization paved the way for the re-engineering of the portal itself. The outcome is an easily deployable package customized with relevant information sources and specific decentralized operational requirements. This package is composed of a generic and scalable data access mechanism, Lavoisier; a renowned php framework for configuration flexibility, Symfony and a MySQL database. VO life cycle and operational information, EGEE broadcast and Downtime notifications are next for the major reorganization until all other key features of the Operations Portal are migrated to the framework. Features specifications will be sketched at the same time to adapt to EGI requirements and to upgrade. Future work on feature regionalisation, on new advanced features or strategy planning will be tracked in EGI- Inspire through the Operations Tools Advisory Group, OTAG, where all users, customers and third parties of the Operations Portal are represented from January 2010.

  10. Energy implications of integrated solid waste management systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Little, R.E.; McClain, G.; Becker, M.; Ligon, P.; Shapiro, K.

    1994-07-01

    This study develops estimates of energy use and recovery from managing municipal solid waste (MSW) under various collection, processing, and disposal scenarios. We estimate use and recovery -- or energy balance -- resulting from MSW management activities such as waste collection, transport, processing, and disposal, as well as indirect use and recovery linked to secondary materials manufacturing using recycled materials. In our analysis, secondary materials manufacturing displaces virgin materials manufacturing for 13 representative products. Energy implications are expressed as coefficients that measure the net energy saving (or use) of displacing products made from virgin versus recycled materials. Using data developed for the 1992 New York City Master Plan as a starting point, we apply our method to an analysis of various collection systems and 30 types of facilities to illustrate bow energy balances shift as management systems are modified. In sum, all four scenarios show a positive energy balance indicating the energy and advantage of integrated systems versus reliance on one or few technology options. That is, energy produced or saved exceeds the energy used to operate the solid waste system. The largest energy use impacts are attributable to processing, including materials separation and composting. Collection and transportation energy are relatively minor contributors. The largest two contributors to net energy savings are waste combustion and energy saved by processing recycled versus virgin materials. An accompanying spatial analysis methodology allocates energy use and recovery to New York City, New York State outside the city, the U.S., and outside the U.S. Our analytical approach is embodied in a spreadsheet model that can be used by energy and solid waste analysts to estimate impacts of management scenarios at the state and substate level.

  11. Distributed Energy Neural Network Integration System: Year One Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Regan, T.; Sinnock, H.; Davis, A.

    2003-06-01

    This report describes the work of Orion Engineering Corp. to develop a DER household controller module and demonstrate the ability of a group of these controllers to operate through an intelligent, neighborhood controller. The controllers will provide a smart, technologically advanced, simple, efficient, and economic solution for aggregating a community of small distributed generators into a larger single, virtual generator capable of selling power or other services to a utility, independent system operator (ISO), or other entity in a coordinated manner.

  12. Comprehensive Final Report for the Marine Seismic System Program

    Science.gov (United States)

    1985-08-01

    serve as a principal reference for transitioning marine seismic system techniques and results from the research and development arena to the...vM . .’ .■ .» .%■■.•. - Viaj ^."-;/-.■■ *• -’•’■■’■ ■ ■ - ■ • ■ -. . -. • ^;-■:■:-:•:> •■•."--.--.v. ’-• V ’.■ *.- ".i • ■ - ■ ■ v V

  13. Development of geothermal-well-completion systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, E.B.

    1979-01-01

    Results of a three year study concerning the completion of geothermal wells, specifically cementing, are reported. The research involved some specific tasks: (1) determination of properties an adequate geothermal well cement must possess; (2) thorough evaluation of current high temperature oilwell cementing technology in a geothermal context; (3) basic research concerning the chemical and physical behavior of cements in a geothermal environment; (4) recommendation of specific cement systems suitable for use in a geothermal well.

  14. Final Technical Report "Multiscale Simulation Algorithms for Biochemical Systems"

    Energy Technology Data Exchange (ETDEWEB)

    Petzold, Linda R.

    2012-10-25

    Biochemical systems are inherently multiscale and stochastic. In microscopic systems formed by living cells, the small numbers of reactant molecules can result in dynamical behavior that is discrete and stochastic rather than continuous and deterministic. An analysis tool that respects these dynamical characteristics is the stochastic simulation algorithm (SSA, Gillespie, 1976), a numerical simulation procedure that is essentially exact for chemical systems that are spatially homogeneous or well stirred. Despite recent improvements, as a procedure that simulates every reaction event, the SSA is necessarily inefficient for most realistic problems. There are two main reasons for this, both arising from the multiscale nature of the underlying problem: (1) stiffness, i.e. the presence of multiple timescales, the fastest of which are stable; and (2) the need to include in the simulation both species that are present in relatively small quantities and should be modeled by a discrete stochastic process, and species that are present in larger quantities and are more efficiently modeled by a deterministic differential equation (or at some scale in between). This project has focused on the development of fast and adaptive algorithms, and the fun- damental theory upon which they must be based, for the multiscale simulation of biochemical systems. Areas addressed by this project include: (1) Theoretical and practical foundations for ac- celerated discrete stochastic simulation (tau-leaping); (2) Dealing with stiffness (fast reactions) in an efficient and well-justified manner in discrete stochastic simulation; (3) Development of adaptive multiscale algorithms for spatially homogeneous discrete stochastic simulation; (4) Development of high-performance SSA algorithms.

  15. Behavior-aware decision support systems : LDRD final report.

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, Gary B.; Homer, Jack (Homer Consulting); Chenoweth, Brooke N.; Backus, George A.; Strip, David R.

    2007-11-01

    As Sandia National Laboratories serves its mission to provide support for the security-related interests of the United States, it is faced with considering the behavioral responses that drive problems, mitigate interventions, or lead to unintended consequences. The effort described here expands earlier works in using healthcare simulation to develop behavior-aware decision support systems. This report focuses on using qualitative choice techniques and enhancing two analysis models developed in a sister project.

  16. Final safety analysis report for the atmospheric protection system

    International Nuclear Information System (INIS)

    1976-06-01

    An Atmospheric Protection System (APS) has been constructed at the Idaho Chemical Processing Plant to minimize the release of radioactive particulate material to the atmosphere from nonroutine occurrences. Existing off-gas cleanup systems remove radioactive particulates to well below allowable limits for controlled areas before release to the plant stack. Previously all ventilation air from process cells was discharged to the stack without treatment. The APS provides continuous filtration of all ventilation air from process cells and backup filtration of all process off gases before they are released to the atmosphere. A safety analysis of the potential hazards associated with the APS has been completed. The review indicates that the system is capable of withstanding design basis natural phenomena including a flood, tornado, and earthquake without releasing unacceptable amounts of radioactive particulate from the filters to the environment. An in-cell explosion, fire, mechanical damage, and other postulated accident situations were investigated. From these, the design basis accident postulated for the facility is complete release of the maximum amount of radioactive particulate collected on the 104 ventilation air HEPA filters to the atmosphere via the 250-foot high stack. Even though the release of all the radioactive particulate contained on the filters is hardly credible, it would not present an unacceptable hazard to personnel on or offsite

  17. New vision solar system mission study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Mondt, J.F.; Zubrin, R.M.

    1996-03-01

    The vision for the future of the planetary exploration program includes the capability to deliver {open_quotes}constellations{close_quotes} or {open_quotes}fleets{close_quotes} of microspacecraft to a planetary destination. These fleets will act in a coordinated manner to gather science data from a variety of locations on or around the target body, thus providing detailed, global coverage without requiring development of a single large, complex and costly spacecraft. Such constellations of spacecraft, coupled with advanced information processing and visualization techniques and high-rate communications, could provide the basis for development of a {open_quotes}virtual{close_quotes} {open_quotes}presence{close_quotes} in the solar system. A goal could be the near real-time delivery of planetary images and video to a wide variety of users in the general public and the science community. This will be a major step in making the solar system accessible to the public and will help make solar system exploration a part of the human experience on Earth.

  18. Active system area networks for data intensive computations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-04-01

    The goal of the Active System Area Networks (ASAN) project is to develop hardware and software technologies for the implementation of active system area networks (ASANs). The use of the term ''active'' refers to the ability of the network interfaces to perform application-specific as well as system level computations in addition to their traditional role of data transfer. This project adopts the view that the network infrastructure should be an active computational entity capable of supporting certain classes of computations that would otherwise be performed on the host CPUs. The result is a unique network-wide programming model where computations are dynamically placed within the host CPUs or the NIs depending upon the quality of service demands and network/CPU resource availability. The projects seeks to demonstrate that such an approach is a better match for data intensive network-based applications and that the advent of low-cost powerful embedded processors and configurable hardware makes such an approach economically viable and desirable.

  19. Accelerating Acceptance of Fuel Cell Backup Power Systems - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Petrecky, James; Ashley, Christopher

    2014-07-21

    Since 2001, Plug Power has installed more than 800 stationary fuel cell systems worldwide. Plug Power’s prime power systems have produced approximately 6.5 million kilowatt hours of electricity and have accumulated more than 2.5 million operating hours. Intermittent, or backup, power products have been deployed with telecommunications carriers and government and utility customers in North and South America, Europe, the United Kingdom, Japan and South Africa. Some of the largest material handling operations in North America are currently using the company’s motive power units in fuel cell-powered forklifts for their warehouses, distribution centers and manufacturing facilities. The low-temperature GenSys fuel cell system provides remote, off-grid and primary power where grid power is unreliable or nonexistent. Built reliable and designed rugged, low- temperature GenSys delivers continuous or backup power through even the most extreme conditions. Coupled with high-efficiency ratings, low-temperature GenSys reduces operating costs making it an economical solution for prime power requirements. Currently, field trials at telecommunication and industrial sites across the globe are proving the advantages of fuel cells—lower maintenance, fuel costs and emissions, as well as longer life—compared with traditional internal combustion engines.

  20. Systems Analysis of NASA Aviation Safety Program: Final Report

    Science.gov (United States)

    Jones, Sharon M.; Reveley, Mary S.; Withrow, Colleen A.; Evans, Joni K.; Barr, Lawrence; Leone, Karen

    2013-01-01

    A three-month study (February to April 2010) of the NASA Aviation Safety (AvSafe) program was conducted. This study comprised three components: (1) a statistical analysis of currently available civilian subsonic aircraft data from the National Transportation Safety Board (NTSB), the Federal Aviation Administration (FAA), and the Aviation Safety Information Analysis and Sharing (ASIAS) system to identify any significant or overlooked aviation safety issues; (2) a high-level qualitative identification of future safety risks, with an assessment of the potential impact of the NASA AvSafe research on the National Airspace System (NAS) based on these risks; and (3) a detailed, top-down analysis of the NASA AvSafe program using an established and peer-reviewed systems analysis methodology. The statistical analysis identified the top aviation "tall poles" based on NTSB accident and FAA incident data from 1997 to 2006. A separate examination of medical helicopter accidents in the United States was also conducted. Multiple external sources were used to develop a compilation of ten "tall poles" in future safety issues/risks. The top-down analysis of the AvSafe was conducted by using a modification of the Gibson methodology. Of the 17 challenging safety issues that were identified, 11 were directly addressed by the AvSafe program research portfolio.