WorldWideScience

Sample records for portal monitoring technology

  1. Portal monitoring technology control process

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    Portal monitors are an important part of the material protection, control, and accounting (MPC and A) programs in Russia and the US. Although portal monitors are only a part of an integrated MPC and A system, they are an effective means of controlling the unauthorized movement of special nuclear material (SNM). Russian technical experts have gained experience in the use of SNM portal monitors from US experts ad this has allowed them to use the monitors more effectively. Several Russian institutes and companies are designing and manufacturing SNM portal monitors in Russia. Interactions between Russian and US experts have resulted in improvements to the instruments. SNM portal monitor technology has been effectively transferred from the US to Russia and should be a permanent part of the Russian MPC and A Program. Progress in the implementation of the monitors and improvements to how they are used are discussed

  2. Roadside Tracker Portal-less Portal Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Ziock, Klaus-Peter [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cheriyadat, Anil M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bradley, Eric Craig [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cunningham, Mark F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fabris, Lorenzo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goddard, Jr, James Samuel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hornback, Donald Eric [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Karnowski, Thomas Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kerekes, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Newby, Jason [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-07-01

    This report documents the full development cycle of the Roadside Tracker (RST) Portal-less Portal monitor (Fig. 1) funded by DHS DNDO. The project started with development of a proof-of-feasibility proto-type, proceeded through design and construction of a proof-of-concept (POC) prototype, a test-and-evaluation phase, participation in a Limited Use Exercise that included the Standoff Radiation Detections Systems developed under an Advanced Technology Demonstration and concluded with participation in a Characterization Study conducted by DNDO.

  3. Interactive monitoring portal for fusion simulations

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D.P.; Kim, E.N.; Flanagan, S.M.; Lee, X.

    2012-01-01

    Highlights: ► We designed a web-based monitoring system that tracks the status of fusion simulations. ► Our system is scalable to monitor the simulations running on distributed supercomputers and clusters located at multiple geographical locations. ► The monitoring portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. ► Our system utilizes the open source software, such as Python, Django, MySQL, Apache, and MDSplus. - Abstract: The Center for Simulation of RF Wave Interactions with Magnetohydrodynamics (SWIM) Project is a proto-Fusion Simulation Program (FSP) whose goal is to study high-performance fusion plasmas and perform comprehensive simulations that are essential to the development of fusion. SWIM team members are geographically distributed and utilize distributed supercomputers for computational simulations. Due to the highly distributed computational work environment, the SWIM team has the difficulty of monitoring code runs and discovering historical runs. To alleviate this difficulty a web-based monitoring portal has been developed and deployed. The monitoring portal tracks the progress of simulations and automatically collects metadata in real-time. This capability helps scientists to effectively utilize precious computer resources. Furthermore, the portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. The user interface provides rapid discovery capability via multi-field searching and sorting. The development of the monitoring portal used open source software, such as Python, Django, MySQL, and Apache. It uses MDSplus for data management, Memcached for data caches, and OpenID for single sign-on security. This paper describes the software architecture, related technologies and deployment experiences of the monitoring portal.

  4. Portal monitor incorporating smart probes

    International Nuclear Information System (INIS)

    Bartos, D.; Constantin, F.; Guta, T.

    2003-01-01

    Portal monitors are intended for detection of radioactive and special nuclear materials in vehicles, pedestrians, luggage, as well as for prevention of illegal traffic of radioactive sources. Monitors provide audio and visual alarms when radioactive and/or special nuclear materials are detected. They can be recommended to officers of customs, border guard and emergency services, civil defense, fire brigades, police and military departments or nuclear research or energetic facilities. The portal monitor developed by us consists in a portal frame, which sustains five intelligent probes having long plastic scintillator (0.5 liters each). The probes communicate, by serial transmission, with a Central Unit constructed on the basis of the 80552 microcontroller. This one manages the handshake, calculates the background, establishes the measuring time, starts and stops each measurement and makes all the other decisions. Sound signals and an infrared sensor monitor the passing through the portal and the measuring procedure. For each measurement the result is displayed on a LCD device contaminated/uncontaminated; for the contaminated case a loud and long sound signal is also issued. An RS 232 serial interface is provided in order to further developments or custom made devices. As a result, the portal monitor detects 1 μ Ci 137 Cs, spread all over a human body, in a 20 μR/h gamma background for a measuring time of 1.5 or 10 seconds giving a 99% confidence factor. (authors)

  5. A neutron portal monitor for vehicles

    International Nuclear Information System (INIS)

    Coop, K.L.; Fehlau, P.E.; Atwater, H.F.

    1987-01-01

    We have designed and built a portal vehicle monitoring systems for detecting neutron-emitting special nuclear material (SNM) such as plutonium. Monte Carlo calculations were used to optimize the design of the 15-cm-deep x 122-cm-high x 244-cm-long detector chambers, which utilize 3 He proportional counters inside a hollow polyethylene box. Results for a variety of parametric studies, including polyethylene thickness and detector number, are described. Our experimental measurements are in good agreement with the computer calculations. The monitor's decision logic uses the Sequential Probability Ratio Test (SPRT) on Poisson distributed counting data, which is superior to other statistical tests in many applications. We performed computer simulations of the SPRT logic to determine expected false-positive decision rates. A controller unit of our design that uses this SPRT was built commercially. The cost of the complete monitoring system is similar to that of vehicle portal monitors that detect gamma rays. This new neutron monitor can serve as an addition to standard gamma-ray vehicle portals or as a stand-alone portal monitor in particular safeguards monitoring situations. The monitor is being tested at Los Alamos and is scheduled for in-plant evaluation of another DOE facility in 1987. 7 refs

  6. Portal monitoring for detecting fissile materials and chemical explosives

    International Nuclear Information System (INIS)

    Albright, D.

    1992-01-01

    The portal monitoring of pedestrians, packages, equipment, and vehicles entering or leaving areas of high physical security has been common for many years. Many nuclear facilities rely on portal monitoring to prevent the theft or diversion of plutonium and highly enriched uranium. At commercial airports, portals are used to prevent firearms and explosives from being smuggled onto airplanes. An August 1989 Federal Aviation Administration (FAA) regulation requires US airlines to screen luggage on international flights for chemical explosives. This paper reports that portal monitoring is now being introduced into arms-control agreements. Because some of the portal-monitoring equipment that would be useful in verifying arms-control agreements is already widely used as part of the physical security systems at nuclear facilities and commercial airports, the authors review these uses of portal monitoring, as well as its role in verifying the INF treaty. Then the authors survey the major types of portal-monitoring equipment that would be most useful in detecting nuclear warheads or fissile material

  7. Portal monitor evaluation and test procedure

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Rich, B.L.

    1983-10-01

    The purpose was to develop techniques and procedures to allow users to measure performance and sensitivity of portal monitors. Additionally, a methodology was developed to assist users in optimizing monitor performance. The two monitors tested utilized thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: a) background count rate and the statistical variability, b) detector efficiency at different distances, c) moving source sensitivity for various size sources and speeds, and d) false alarm rates at different background levels. A model was developed for the moving source measurements to compare the experimental data with measured results, and to test whether it is possible to adequately model the behavior of a portal monitor's response to a moving source. The model results were compared with the actual test results. A procedure for testing portal monitors is also given. 1 reference, 9 figures, 8 tables

  8. Large vehicle portal monitor for perimeter safeguards applications

    International Nuclear Information System (INIS)

    Caldwell, J.T.; Atwater, H.F.; Bernard, W.; Bieri, J.M.; Shunk, E.R.

    1979-01-01

    We have developed a class of vehicle portal monitors based on shielded 4π geometry neutron counting. we have derived and experimentally verified an analytical expression relating the detection sensitivity of the neutron tunnel vehicle portal monitor to four design parameters of the system. For a given number of neutron detectors, this design achieves one or more orders of magnitude improvement in nuclear materials detection sensitivity over previous vehicle portal monitors

  9. The role of SNM portal monitoring in the Russian MPC ampersand A program

    International Nuclear Information System (INIS)

    York, R.L.

    1997-01-01

    Controlling the movement of nuclear materials is still the most effective nonproliferation measure. Pedestrian and vehicle portal monitors have been an established tool for preventing the unauthorized movement of SNM across US nuclear facility boundaries for 15 years. Because the portals are reliable and easy to install, they are an efficient first step to improve the security at Russian nuclear facilities. The portals were first furnished to Russian facilities for testing and evaluation. After Russian technical experts gained experience with the operating parameters, the instruments were implemented at appropriate locations at each facility. This process has been executed at IPPE, VNIEF, VNIITF, RCC KI, and SKhK. The transfer of the portal monitoring technology to Russian institutes to promote the manufacture of Russian instruments is also an important goal of the program. The process was started with two portal monitor workshops attended by representatives of Russian facilities at ORNL and followed by technical collaborations at the individual Russian facilities. The success of this effort is illustrated by the recent workshop hosted by VNIIA at the SCI in Obninsk where specialists from thirty-two Russian nuclear facilities met to discuss their experience in portal monitoring. Twelve institutes and firms reported on the status of Russian designed and manufactured instruments. Details of this program will be presented in this paper

  10. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Energy Technology Data Exchange (ETDEWEB)

    Paff, Marc Gerrit, E-mail: mpaff@umich.edu; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-21

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  11. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-01

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  12. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  13. Testing of portal monitors for personnel contamination control

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Stalker, A.C.; Baker, K.R.; Littleton, M.L.; Rich, B.L.

    1983-04-01

    This is a report of an INPO-funded evaluation of state-of-the-art portal monitors used to detect personnel contamination. The project developed techniques and procedures to evaluate the performance and sensitivity of the portal monitors which provided data for intercomparison. An additional accomplishment was development of a methodology to assist manufacturers and users to optimize the monitor settings, and to provide technical basis for the eventual use of fixed monitors to replace frisking for contamination control. The monitors tested utilize thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: (1) background count rate and the statistical variability, (2) detector efficiency at different distances, (3) moving source sensitivity for various size sources and speeds, and (4) false alarm rates at different background levels. A model has been developed for the moving source measurements to compare the experimental data, and to test whether it is possible to adequately model the behavior of a portal monitor response to a moving source. The model results with the actual test results are compared

  14. Technical aspects of portal technology application for e-health systems.

    Science.gov (United States)

    Kosińska, Joanna; Słowikowski, Paweł

    2004-01-01

    E-health is an emerging field on the intersection of medical information technologies, public health and business, referring to health services and information delivered or enhanced through the Internet and related technologies. Portal technology, allowing services to be accessible over the Internet is a perfect tool for providing e-health services. The use of portal technologies has had deep influence on the architecture of the whole e-health system, both regarding new subsystems and older ones which we want to integrate with the portal. Portals provide new possibilities for creating novel types of e-health applications as well. In this paper we provide a brief overview of e-health systems and portal technologies, and present many technical aspects of portal technology application for e-health systems such as the architecture of portal-based e-health systems, graphical user interfaces, access to various e-health systems' resources, personalization, security and privacy.

  15. Uzbekistan Radiation Portal Monitoring System

    International Nuclear Information System (INIS)

    Richardson, J; Knapp, R; Loshak, A; Yuldashev, B; Petrenko, V

    2005-01-01

    The work proposed in this presentation builds on the foundation set by the DTRA funded demonstration project begun in 2000 and completed in December of 2003. This previous work consisted of two phases whose overall objective was to install portal radiation monitors at four select ports-of-entry in Uzbekistan (Tashkent International Airport, Gisht-Kuprik (Kazakhstan border), Alat (Turkmenistan border), and Termez (Afghanistan border)) in order to demonstrate their effectiveness in preventing the illicit trafficking of nuclear materials. The objectives also included developing and demonstrating capabilities in the design, installation, operation, training, and maintenance of a radiation portal monitoring system. The system and demonstration project has proved successful in many ways. An effective working relationship among the Uzbekistan Customs Services, Uzbekistan Border Guards, and Uzbekistan Institute of Nuclear Physics has been developed. There has been unprecedented openness with the sharing of portal monitor data with Lawrence Livermore National Laboratory. The system has proved to be effective, with detection of illicit trafficking, and, at Alat, an arrest of three persons illegally transporting radioactive materials into Turkmenistan. The demonstration project has made Uzbekistan a model nonproliferation state in Central Asia and, with an expanded program, places them in a position to seal a likely transit route for illicit nuclear materials. These results will be described. In addition, this work is currently being expanded to include additional ports-of-entry in Uzbekistan. The process for deciding on which additional ports-of-entry to equip will also be described

  16. Increase in Efficiency of Use of Pedestrian Radiation Portal Monitors

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    Most international airports in the world use radiation portal monitors (RPM) for primary radiation control organization. During the exploitation pedestrian radiation portal monitors operators (in the Russian Federation it is a special subdivision of customs officials) have certain problems related to the search of an ionizing radiation source causing the alarm signal of a radiation monitor. Radiation portal monitors at standard (factory) settings have to find out the illegal moving of the radioisotopes moved by physical persons passing through a controlled zone and having a steady radiation by the gamma or neutron channel. The problem is that recently the number of the ownerships who underwent treatment or medical diagnostics with the use of radio pharmaceuticals considerably increased, i.e,. ownerships represent such an ionizing radiation source. The operator of the radiation portal monitor has to define very quickly whether the ownership is a violator (takes unsolved radioisotopes illegally) or is just a patient of the clinic who underwent treatment/diagnostics with the use of radio pharmaceuticals. The research showing the radioisotopes which are most often used in the medical purposes are given in article, it is offered to use the new software developed by the authors allowing the operator of the radiation portal monitor to define the location of the ownership which has such ionizing radiation source by the activity of radiation similar to the radiation from radio pharmaceuticals.

  17. New ICPP portal monitor

    International Nuclear Information System (INIS)

    Georgeson, M.A.; Nichols, C.E.

    1981-04-01

    A large area gas filled proportional-detector portal monitor mounted in a swinging door frame has been designed and developed at the Idaho Chemical Processing Plant (ICPP). This monitor extends the sensitivity and speed of personnel contamination detection to levels equal to or exceeding that obtained using hand-held portable survey techniques. The new monitor has state-of-the-art electronics which result in rapid response, and use statistical principles in the alarm logic to reduce or eliminate spurious alarms. In addition, the evaluation of this instrument indicates that it will detect small enough quantities of U-235 in shielded containers to meet current special nuclear materials (SNM) detection standards. Simultaneous detection of very low level contamination and small quantities of SNM results in a monitor particularly useful for nuclear installations

  18. Special Nuclear Material Portal Monitoring at the Nevada Test Site

    International Nuclear Information System (INIS)

    DeAnn Long; Michael Murphy

    2008-01-01

    Prior to April 2007, acceptance and performance testing of the various Special Nuclear Material (SNM) monitoring devices at the Nevada Test Site (NTS) was performed by the Radiological Health Instrumentation department. Calibration and performance testing on the PM-700 personnel portal monitor was performed, but there was no test program for the VM-250 vehicle portal monitor. The handheld SNM monitors, the TSA model 470B, were being calibrated annually, but there was no performance test program. In April of 2007, the Material Control and Accountability Manager volunteered to take over performance testing of all SNM portal monitors at NTS in order to strengthen the program and meet U.S. Department of Energy Order requirements. This paper will discuss the following activities associated with developing a performance testing program: changing the culture, learning the systems, developing and implementing procedures, troubleshooting and repair, validating the process, physical control of equipment, acquisition of new systems, and implementing the performance test program

  19. Special Nuclear Material Portal Monitoring at the Nevada Test Site

    International Nuclear Information System (INIS)

    Mike Murphy

    2008-01-01

    In the past, acceptance and performance testing of the various Special Nuclear Material (SNM) monitoring devices at the Nevada Test Site has been performed by the Radiological Health Instrumentation Department. Calibration and performance tests on the PM-700 personnel portal monitor were performed but there was no test program for the VM-250 vehicle portal monitor because it had never been put into service. The handheld SNM monitors, the TSA model 470B, were being calibrated annually, but there was no program in place to test them quarterly. In April of 2007, the Material Control and Accountability (MC and A) Manager at the time decided that the program needed to be strengthened and MC and A took over performance testing of all SNM portal monitoring equipment. This paper will discuss the following activities associated with creating a performance testing program: changing the culture, learning the systems, writing procedures, troubleshooting/repairing, validating the process, control of equipment, acquisition of new systems, and running the program

  20. ICPP digital wide area portal monitor

    International Nuclear Information System (INIS)

    Nichols, C.E.

    1978-01-01

    A portal montior is described which is used to check personnel for contamination. The monitor is extremely sensitive. In addition to personnel contamination control, it serves as an extremely effective SNM detector capable of detecting U-235 in half the quantities specified in Federal Standards

  1. Study of radiation portal monitor and its application to metal recycling industry

    International Nuclear Information System (INIS)

    Pujol, L.; Lara-Calleja, S.; Suarez-Navarro, M. J.; Gonzalez-Gonzalez, J. A.

    2009-01-01

    The industry of the iron and the steel in one of the most important sectors in Spain for its economic development. the recycling of metallic materials as well as the import of metallic scrap is very significant. Several reports on accidental dispersion or smelting of radioactive sources in metal recycling industries confirm the possibility that radioactive material might be mixed with scrap. In consequence, this type of accident shows the necessity of a rigorous and specific radiation control of the sector. The control of these materials with radioactive content can be carried out with radiation portal monitors installed at the entrance of these industries. The detection of radioactive materials presents special features as the continuous background acquisition or the minimisation of the relatively large number of innocent/nuisance detections. In the present work, we study a radiation portal monitor, the FHT-1388-T Thermo-Eberline. This is one of the usual radiation portal systems installed at the entrance of the metal recycling industry. Se study the characteristics and parameters of this portal monitor to optimise its use. furthermore, we propose some rapid tests for radiation portal systems in metal recycling industry. (Author) 16 refs

  2. Use of Portal Monitors for Detection of Technogenic Radioactive Sources in Scrap Metal

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    The article considers the features of organization of scrap-metal primary radiation control on the specialized enterprises engaging in its deep processing and storage at using by primary technical equipment - radiation portal monitors. The issue of this direction relevance, validity of radiation control implementation with the use of radiation portal monitors, physical and organizational bases of radiation control are considered in detail. The emphasis is put on the considerable increase in the number of technogenic radioactive sources detected in scrap-metal that results in the entering into exploitation of radioactive metallic structures as different building wares. One of reasons of such increase of the number of technogenic radioactive sources getting for processing with scrap-metal is the absence of any recommendations on the radiation portal monitors exploitation. The practical division of the article offers to recommendation on tuning of the modes of work of radiation portal monitors depending on influence the weather factor thus allowing to considerably increase the percent of technogenic radioactive sources detection.

  3. On the usefulness of portal monitor unit subtraction in radiation therapy

    International Nuclear Information System (INIS)

    Kuperman, Vadim Y; Lubich, Leslie M

    2003-01-01

    In order to avoid additional dose to patients caused by portal imaging with megavoltage x-rays, portal monitor units (MUs) are frequently subtracted from the actual treatment MUs. This study examines the usefulness of portal MU subtraction in radiation therapy. For 11 prostate cancer patients treated with 23 MV photons, dose to prostate due to portal filming with 6 MV photons was determined. In all 11 patients subtraction of portal MU values from the actual treatment MUs resulted in a small underdosing of the prostate with an average treatment error of -0.5%. Portal filming without MU subtraction would cause small overdosing of the prostate with an average treatment error of 1.2%. The results of this study indicate that the benefits of portal MU subtraction are in doubt if (a) the energy of treatment x-rays is much higher than that of the portal x-rays and/or (b) when radiotherapy is performed with physical wedges. Based on the obtained results, we argue against unconditional use of the portal MU subtraction method to eliminate the dose from portal imaging

  4. R2 Water Quality Portal Monitoring Stations

    Science.gov (United States)

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  5. The consideration and practice of data processing of WBS-II portal β monitor

    International Nuclear Information System (INIS)

    Du Xiangyang; Dong Qiangmin; Zhang Yong; Han Shuping; Wang Xiaodong; Fan Liya; Rao Xianming

    2001-01-01

    The main aspects of background and human body measurement data processing of WBS-II Portal β Monitor were discussed. The theory analysis of setting high and low background-warning threshold in data processing was done. The relative reference values were partly provided to the local executives. The measurement 'blind zone' and the whole warning function of data processing were discussed. And the structure, the process of monitoring and the microcomputer's hard wares of WBS-II Portal β Monitor were simply introduced

  6. Integrating Space Communication Network Capabilities via Web Portal Technologies

    Science.gov (United States)

    Johnston, Mark D.; Lee, Carlyn-Ann; Lau, Chi-Wung; Cheung, Kar-Ming; Levesque, Michael; Carruth, Butch; Coffman, Adam; Wallace, Mike

    2014-01-01

    We have developed a service portal prototype as part of an investigation into the feasibility of using Java portlet technology as a means of providing integrated access to NASA communications network services. Portal servers provide an attractive platform for this role due to the various built-in collaboration applications they can provide, combined with the possibility to develop custom inter-operating portlets to extent their functionality while preserving common presentation and behavior. This paper describes various options for integration of network services related to planning and scheduling, and results based on use of a popular open-source portal framework. Plans are underway to develop an operational SCaN Service Portal, building on the experiences reported here.

  7. A portal of educational resources: providing evidence for matching pedagogy with technology

    Directory of Open Access Journals (Sweden)

    Nicoletta Blas

    2014-05-01

    Full Text Available The TPACK (Technology, Pedagogy and Content Knowledge model presents the three types of knowledge that are necessary to implement a successful technology-based educational activity. It highlights how the intersections between TPK (Technological Pedagogical Knowledge, PCK (Pedagogical Content Knowledge and TCK (Technological Content Knowledge are not a sheer sum up of their components but new types of knowledge. This paper focuses on TPK, the intersection between technology knowledge and pedagogy knowledge – a crucial field of investigation. Actually, technology in education is not just an add-on but is literally reshaping teaching/learning paradigms. Technology modifies pedagogy and pedagogy dictates requirements to technology. In order to pursue this research, an empirical approach was taken, building a repository (back-end and a portal (front-end of about 300 real-life educational experiences run at school. Educational portals are not new, but they generally emphasise content. Instead, in our portal, technology and pedagogy take centre stage. Experiences are classified according to more than 30 categories (‘facets’ and more than 200 facet values, all revolving around the pedagogical implementation and the technology used. The portal (an innovative piece of technology supports sophisticated ‘exploratory’ sessions of use, targeted at researchers (investigating the TPK intersection, teachers (looking for inspiration in their daily jobs and decision makers (making decisions about the introduction of technology into schools.

  8. Portals people, processes, technology

    CERN Document Server

    Cox, Andrew

    2006-01-01

    First applied to internet gateways such as Yahoo, the concept of the ""portal"" has evolved in a number of directions. How can information services best take advantage of internet portals to improve access to resources? This collection seeks answers to such questions, providing an overview of how portals are being used.

  9. Comparison of MCNP and Experimental Measurements for an HPGe-based Spectroscopy Portal Monitor

    International Nuclear Information System (INIS)

    Keyser, Ronald M.; Hensley, Walter K.; Twomey, Timothy R.; UPP, Daniel L.

    2008-01-01

    The necessity to monitor international commercial transportation for illicit nuclear materials resulted in the installation of many nuclear radiation detection systems in Portal Monitors. These were mainly gross counters which alarmed at any indication of high radioactivity in the shipment, the vehicle or even the driver. The innocent alarm rate, due to legal shipments of sources and NORM, or medical isotopes in patients, caused interruptions and delays in commerce while the legality of the shipment was verified. To overcome this difficulty, Department of Homeland Security (DHS) supported the writing of the ANSI N42.38 standard (Performance Criteria for Spectroscopy-Based Portal Monitors used for Homeland Security) to define the performance of a Portal Monitor with nuclide identification capabilities, called a Spectroscopy Portal Monitor. This standard defines detection levels and response characteristics for the system for energies from 25 keV to 3 MeV. To accomplish the necessary performance, several different HPGe detector configurations were modeled using MCNP for the horizontal field of view (FOV) and vertical linearity of response over the detection zone of 5 meters by 4.5 meters for 661 keV as representative of the expected nuclides of interest. The configuration with the best result was built and tested. The results for the FOV as a function of energy and the linearity show good agreement with the model and performance exceeding the requirements of N42.38

  10. Application of SharePoint Portal Technologies in Public Enterprises

    Directory of Open Access Journals (Sweden)

    Dragan Đokić

    2015-03-01

    Full Text Available Nowadays, systematic reforms are realized acrossmany countries. One of the characteristics of these reforms is necessity for rationalization of expenses in governmental and public enterprises. Rationalization of expenses can be achieved by more extensive application of information and communication technologies based on internet technologies and cloud computing. These systems include huge number of services, applications, resources, users and roles. At the same time, concepts of scalability, availability, ubiquity and pervasiveness need to be applied. This paper deals with application of portal technologies for enhanced content management, document management, and collaboration within public enterprises. The goal is to achieve efficient exchange of information on all hierarchical levels, as well as mechanisms of reporting and performance measurements, such as business intelligence and key performance indicators. The model is based on SharePoint portal technologies. A case study of application within the public enterprise Post of Serbia is described.

  11. New containment and surveillance portal monitor data analysis methed

    International Nuclear Information System (INIS)

    Henry, C.N.; Pratt, J.C.

    1979-01-01

    A new containment and surveillance portal monitor data analysis method has been developed. Current approaches use only the data from a single passage and an average background interval for alarm determination. The new method improves performance by summing the counts from many passages for comparison to the expected count, thus improving the statistical accuracy

  12. Radioactivity Portal Monitor: An actual application and its unconventional detector

    International Nuclear Information System (INIS)

    Izraelevitch, F.; Matatagui, E.; Regueiro Veiga, J.L.

    2012-01-01

    A Radioactivity Portal Monitor is an instrument designed to be used at traffic check points to detect the presence of ionizing radiation in goods, vehicles, people, in critical places such as those at border road crossing, airports and seaports, the entrance at nuclear facilities etc. and alert the officer to the presence of radioactive and nuclear material. We have developed and built, and is in operation a Radioactivity Portal Monitor for gamma radiation. The detector and the associated electronics does not follow a conventional design concept and is based on a pressurized ionization chamber with a very large sensitive volume (60 liters) and a very large length (2 meters), and a very low level DC electronics (fAmp). The System is simple, and its operational characteristics are excellent. The reference radiation level is the background radiation, which is continuously measured, and compared with the radiation level measured when a subject (vehicle, person, good) goes trough the Monitor. The system automatically takes a decision, and alert the officer with an alarm signal if the detected radiation level is larger than the reference (dynamical) level. We will describe the designed system and some of its characterization results will be shown (author)

  13. Development of integrated containment and surveillance system for fast critical facility FCA. Portal and penetration monitors

    International Nuclear Information System (INIS)

    Mukaiyama, Takehiko; Ogawa, Hironobu; Yokota, Yasuhiro.

    1998-01-01

    Manpower and radiation exposure problems, accompanied by frequent Non Destructive Assay (NDA) based inspections at the Fast Critical Facility FCA of Japan Atomic Energy Research Institute (JAERI), are a burden for both the inspectorates and the facility operator. In the hope of alleviating these burdens, the development of containment and surveillance measures for the FCA was initiated in 1979. The integrated containment and surveillance system consists of a portal monitor and a penetration monitor. The reactor building provides an ideal containment measure because of its explosion-proof, airtight structure and limited number of penetrations. The function of the portal monitor is to detect undeclared removal of nuclear material from the reactor building through the doorway. The penetration monitor is designed for surveillance of diversion routes through containment boundaries, and of safeguards related activities for bypassing the portal monitor. The combination of monitoring by the penetration monitor of containment boundaries and all their penetrations except for the doorway, and monitoring by the portal monitor, provides complete coverage of realistic diversion routes. The development of the system was completed in 1988 and the field trial test was conducted for the period of twelve running months. The final report on the field trial was concluded on January 1990. The major conclusion of the report was that the system is effective, reliable and efficient. Following this successful conclusion, the International Atomic Energy Agency (IAEA) accepted the system for meeting its safeguards goals at the FCA on condition that an independent IAEA authentication equipment is provided. The development of the authentication equipment is accomplished as an separate Japan Support Programme for Agency Safeguards (JASPAS) task. (author)

  14. Design of microprocessor data acquisition system for pedestrian portal SNM monitor

    International Nuclear Information System (INIS)

    Zhang Wenliang

    2003-01-01

    The paper introduces the hardware structure and composition of data acquisition system for pedestrian portal special nuclear material (SNM) monitor. The hardware and software of single chip microprocessor AT89C52, LCM, keyboard and serial communication interface software are also discussed. (authors)

  15. Customisable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion. Web portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as Twitter and other social networks. In this series of slides, we describe the software architecture of this scientific web portal and our experiences in utilizing web 2.0 technologies. A

  16. Application of a new containment and surveillance portal monitor data analysis method

    International Nuclear Information System (INIS)

    Pratt, J.C.; Henry, C.N.; Hastings, R.D.

    1980-01-01

    A new method for processing the information available from an ordinary doorway monitor in an earlier report is described. Additional tests of this concept on doorway monitors at facilities of the Los Alamos Scientific Laboratory have been made. The lessons learned and estimates of the sensitivity of this method for detection of a trickle of special nuclear material through the portal are presented

  17. Design simplicity influences patient portal use: the role of aesthetic evaluations for technology acceptance

    Science.gov (United States)

    Watkins, Ivan; Mackert, Michael S; Xie, Bo; Stephens, Keri K; Shalev, Heidi

    2016-01-01

    Objective This study focused on patient portal use and investigated whether aesthetic evaluations of patient portals function are antecedent variables to variables in the Technology Acceptance Model. Methods A cross-sectional survey of current patient portals users (N = 333) was conducted online. Participants completed the Visual Aesthetics of Website Inventory, along with items measuring perceived ease of use (PEU), perceived usefulness (PU), and behavioral intentions (BIs) to use the patient portal. Results The hypothesized model accounted for 29% of the variance in BIs to use the portal, 46% of the variance in the PU of the portal, and 29% of the variance in the portal’s PEU. Additionally, one dimension of the aesthetic evaluations functions as a predictor in the model – simplicity evaluations had a significant positive effect on PEU. Conclusion This study provides evidence that aesthetic evaluations – specifically regarding simplicity – function as a significant antecedent variable to patients’ use of patient portals and should influence patient portal design strategies. PMID:26635314

  18. A theoretical approach to calibrate radiation portal monitor (RPM) systems

    International Nuclear Information System (INIS)

    Nafee, Sherif S.; Abbas, Mahmoud I.

    2008-01-01

    Radiation portal monitor (RPM) systems are widely used at international border crossings, where they are applied to the task of detecting nuclear devices, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, the former being required to rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce [Chambers, W.H., Atwater, H.F., Fehlau, P.E., Hastings, R.D., Henry, C.N., Kunz, W.E., Sampson, T.E., Whittlesey, T.H., Worth, G.M., 1974. Portal Monitor for Diversion Safeguards. LA-5681, Los Alamos Scientific Laboratory, Los Alamos, NM]. In the present work, compact analytical formulae are derived and used to calibrate two RPM systems with isotropic radiating sources: (i) polyvinyltoluene (PVT) or plastic and (ii) thallium-doped crystalline sodium iodide, NaI(Tl), gamma-ray detector materials. The calculated efficiencies are compared to measured values reported in the literatures, showing very good agreement

  19. An inverse source location algorithm for radiation portal monitor applications

    International Nuclear Information System (INIS)

    Miller, Karen A.; Charlton, William S.

    2010-01-01

    Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

  20. Radiation portal evaluation parameters

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    The detection of the unauthorized movement of radioactive materials is one of the most effective nonproliferation measures. Automatic special nuclear material (SNM) portal monitors are designed to detect this unauthorized movement and are an important part of the safeguard systems at US nuclear facilities. SNM portals differ from contamination monitors because they are designed to have high sensitivity for the low energy gamma-rays associated with highly enriched uranium (HEU) and plutonium. These instruments are now being installed at international borders to prevent the spread of radioactive contamination an SNM. In this paper the parameters important to evaluating radiation portal monitors are discussed. (author)

  1. New Technology and Experimental Study on Snow-Melting Heated Pavement System in Tunnel Portal

    Directory of Open Access Journals (Sweden)

    Jinxing Lai

    2015-01-01

    Full Text Available In recent years, with the rapid growth of economy and sharp rise of motor vehicles in China, the pavement skid resistance in tunnel portals has become increasingly important in cold region. However, the deicing salt, snow removal with machine, and other antiskid measures adopted by highway maintenance division have many limitations. To improve the treatment effect, we proposed a new snow-melting approach employing electric heat tracing, in which heating cables are installed in the structural layer of road. Through the field experiment, laboratory experiment, and numerical investigation, structure type, heating power, and preheating time of the flexible pavement heating system in tunnel portal were systematically analyzed, and advantages of electric heat tracing technology in improving the pavement skid resistance in tunnel portal were also presented. Therefore, such new technology, which offers new snow-melting methods for tunnel portal, bridge, mountainous area, and large longitudinal slope in cold region, has promising prospect for extensive application.

  2. Design simplicity influences patient portal use: the role of aesthetic evaluations for technology acceptance.

    Science.gov (United States)

    Lazard, Allison J; Watkins, Ivan; Mackert, Michael S; Xie, Bo; Stephens, Keri K; Shalev, Heidi

    2016-04-01

    This study focused on patient portal use and investigated whether aesthetic evaluations of patient portals function are antecedent variables to variables in the Technology Acceptance Model. A cross-sectional survey of current patient portals users (N = 333) was conducted online. Participants completed the Visual Aesthetics of Website Inventory, along with items measuring perceived ease of use (PEU), perceived usefulness (PU), and behavioral intentions (BIs) to use the patient portal. The hypothesized model accounted for 29% of the variance in BIs to use the portal, 46% of the variance in the PU of the portal, and 29% of the variance in the portal's PEU. Additionally, one dimension of the aesthetic evaluations functions as a predictor in the model - simplicity evaluations had a significant positive effect on PEU. This study provides evidence that aesthetic evaluations - specifically regarding simplicity - function as a significant antecedent variable to patients' use of patient portals and should influence patient portal design strategies. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Customizable scientific web portal for fusion research

    International Nuclear Information System (INIS)

    Abla, G.; Kim, E.N.; Schissel, D.P.; Flanagan, S.M.

    2010-01-01

    Web browsers have become a major application interface for participating in scientific experiments such as those in magnetic fusion. The recent advances in web technologies motivated the deployment of interactive web applications with rich features. In the scientific world, web applications have been deployed in portal environments. When used in a scientific research environment, such as fusion experiments, web portals can present diverse sources of information in a unified interface. However, the design and development of a scientific web portal has its own challenges. One such challenge is that a web portal needs to be fast and interactive despite the high volume of information and number of tools it presents. Another challenge is that the visual output of the web portal must not be overwhelming to the end users, despite the high volume of data generated by fusion experiments. Therefore, the applications and information should be customizable depending on the needs of end users. In order to meet these challenges, the design and implementation of a web portal needs to support high interactivity and user customization. A web portal has been designed to support the experimental activities of DIII-D researchers worldwide by providing multiple services, such as real-time experiment status monitoring, diagnostic data access and interactive data visualization. The web portal also supports interactive collaborations by providing a collaborative logbook, shared visualization and online instant messaging services. The portal's design utilizes the multi-tier software architecture and has been implemented utilizing web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services, which allows users to create a unique, personalized working environment to fit their own needs and interests. This paper describes the software

  4. Customizable scientific web portal for fusion research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G., E-mail: abla@fusion.gat.co [General Atomics, P.O. Box 85608, San Diego, CA (United States); Kim, E.N.; Schissel, D.P.; Flanagan, S.M. [General Atomics, P.O. Box 85608, San Diego, CA (United States)

    2010-07-15

    Web browsers have become a major application interface for participating in scientific experiments such as those in magnetic fusion. The recent advances in web technologies motivated the deployment of interactive web applications with rich features. In the scientific world, web applications have been deployed in portal environments. When used in a scientific research environment, such as fusion experiments, web portals can present diverse sources of information in a unified interface. However, the design and development of a scientific web portal has its own challenges. One such challenge is that a web portal needs to be fast and interactive despite the high volume of information and number of tools it presents. Another challenge is that the visual output of the web portal must not be overwhelming to the end users, despite the high volume of data generated by fusion experiments. Therefore, the applications and information should be customizable depending on the needs of end users. In order to meet these challenges, the design and implementation of a web portal needs to support high interactivity and user customization. A web portal has been designed to support the experimental activities of DIII-D researchers worldwide by providing multiple services, such as real-time experiment status monitoring, diagnostic data access and interactive data visualization. The web portal also supports interactive collaborations by providing a collaborative logbook, shared visualization and online instant messaging services. The portal's design utilizes the multi-tier software architecture and has been implemented utilizing web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services, which allows users to create a unique, personalized working environment to fit their own needs and interests. This paper describes the software

  5. Customizable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion experiments. Recently in other areas, web portals have begun to be deployed. These portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. The users can create a unique personalized working environment to fit their own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as

  6. Scanning personnel for internal deposition of radioactive material with personnel contamination whole body friskers and portal monitors

    International Nuclear Information System (INIS)

    Lobdell, J.L.

    1996-01-01

    The potential for using personnel contamination devices such as whole body friskers and portal monitors for internal contamination monitoring was evaluated. Internally deposited radioactive material is typically determined with whole body counting systems. Whole body counts have traditionally been performed on personnel when they report for work, on a periodic basis (i.e., annually), when an uptake is suspected, and on termination. These counts incur significant expense. The monitored personnel pass through whole body friskers and portal monitors daily. This investigation was performed to determine if the external contamination monitors could provide an alternative to the more Costly whole body counting. The ability to detect 1% of a DAC for critical radioisotopes was applied as a detection criteria for this investigation. The results of whole body counts were used to identify the typical internal contamination radionuclides. From this list, the radioisotopes that would be the most difficult to measure were identified. From this review, 60 Co and 131 I were determined to be the critical radionuclides. One percent of a DAC for each isotope was placed, one at a time, in a humanoid phantom. The phantom was placed in the whole body frisker and open-quotes countedclose quotes. The phantom was carried through the portal monitor at a speed equivalent to a person walking through the monitor. Frequency of detection was derived for both systems. Practical aspects of integrating this screening system with traditional internal dosimetry programs are discussed

  7. Customizable scientific web-portal for DIII-D nuclear fusion experiment

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E N; Schissel, D P, E-mail: abla@fusion.gat.co [General Atomics, PO Box 85608, San Diego, California 92186-5608 (United States)

    2010-04-01

    Increasing utilization of the Internet and convenient web technologies has made the web-portal a major application interface for remote participation and control of scientific instruments. While web-portals have provided a centralized gateway for multiple computational services, the amount of visual output often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments. Since each scientist may have different priorities and areas of interest in the experiment, filtering and organizing information based on the individual user's need can increase the usability and efficiency of a web-portal. DIII-D is the largest magnetic nuclear fusion device in the US. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It offers a customizable interface with personalized page layouts and list of services for users to select. Each individual user can create a unique working environment to fit his own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data analysis and visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, and online instant announcement services. The DIII-D web-portal development utilizes multi-tier software architecture, and Web 2.0 technologies and tools, such as AJAX and Django, to develop a highly-interactive and customizable user interface.

  8. Customizable scientific web-portal for DIII-D nuclear fusion experiment

    International Nuclear Information System (INIS)

    Abla, G; Kim, E N; Schissel, D P

    2010-01-01

    Increasing utilization of the Internet and convenient web technologies has made the web-portal a major application interface for remote participation and control of scientific instruments. While web-portals have provided a centralized gateway for multiple computational services, the amount of visual output often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments. Since each scientist may have different priorities and areas of interest in the experiment, filtering and organizing information based on the individual user's need can increase the usability and efficiency of a web-portal. DIII-D is the largest magnetic nuclear fusion device in the US. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It offers a customizable interface with personalized page layouts and list of services for users to select. Each individual user can create a unique working environment to fit his own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data analysis and visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, and online instant announcement services. The DIII-D web-portal development utilizes multi-tier software architecture, and Web 2.0 technologies and tools, such as AJAX and Django, to develop a highly-interactive and customizable user interface.

  9. Customizable scientific web-portal for DIII-D nuclear fusion experiment

    Science.gov (United States)

    Abla, G.; Kim, E. N.; Schissel, D. P.

    2010-04-01

    Increasing utilization of the Internet and convenient web technologies has made the web-portal a major application interface for remote participation and control of scientific instruments. While web-portals have provided a centralized gateway for multiple computational services, the amount of visual output often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments. Since each scientist may have different priorities and areas of interest in the experiment, filtering and organizing information based on the individual user's need can increase the usability and efficiency of a web-portal. DIII-D is the largest magnetic nuclear fusion device in the US. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It offers a customizable interface with personalized page layouts and list of services for users to select. Each individual user can create a unique working environment to fit his own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data analysis and visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, and online instant announcement services. The DIII-D web-portal development utilizes multi-tier software architecture, and Web 2.0 technologies and tools, such as AJAX and Django, to develop a highly-interactive and customizable user interface.

  10. Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Ruch, Marc L.; Poitrasson-Riviere, Alexis; Sagadevan, Athena; Clarke, Shaun D.; Pozzi, Sara

    2015-07-01

    We present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3He-free radiation portal monitor testing campaign at the European Commission's Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group's system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241Am. Both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

  11. The DIRAC Web Portal 2.0

    Science.gov (United States)

    Mathe, Z.; Casajus Ramo, A.; Lazovsky, N.; Stagni, F.

    2015-12-01

    For many years the DIRAC interware (Distributed Infrastructure with Remote Agent Control) has had a web interface, allowing the users to monitor DIRAC activities and also interact with the system. Since then many new web technologies have emerged, therefore a redesign and a new implementation of the DIRAC Web portal were necessary, taking into account the lessons learnt using the old portal. These new technologies allowed to build a more compact, robust and responsive web interface that enables users to have better control over the whole system while keeping a simple interface. The web framework provides a large set of “applications”, each of which can be used for interacting with various parts of the system. Communities can also create their own set of personalised web applications, and can easily extend already existing ones with a minimal effort. Each user can configure and personalise the view for each application and save it using the DIRAC User Profile service as RESTful state provider, instead of using cookies. The owner of a view can share it with other users or within a user community. Compatibility between different browsers is assured, as well as with mobile versions. In this paper, we present the new DIRAC Web framework as well as the LHCb extension of the DIRAC Web portal.

  12. Health literacy and patient portals.

    Science.gov (United States)

    Gu, Yulong; Orr, Martin; Warren, Jim

    2015-06-01

    Health literacy has been described as the capacity to obtain, process, and understand basic health information and services needed to make appropriate health decisions. Improving health literacy may serve to promote concordance with therapy, engage patients in their own health care, and improve health outcomes. Patient portal technology aims at enabling patients and families to have easy access to key information in their own medical records and to communicate with their health care providers electronically. However, there is a gap in our understanding of how portals will improve patient outcome. The authors believe patient portal technology presents an opportunity to improve patient concordance with prescribed therapy, if adequate support is provided to equip patients (and family/carers) with the knowledge needed to utilise the health information available via the portals. Research is needed to understand what a health consumer will use patient portals for and how to support a user to realise the technology's potential.

  13. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  14. Standardisation of radiation portal monitor controls and readouts

    International Nuclear Information System (INIS)

    Tinker, Michael R.

    2010-01-01

    There is an urgent need to standardise the numbering configuration of radiation portal monitor sensing panels. Currently, manufacturers use conflicting numbering schemes that may confuse operators of these varied systems. There is a similar problem encountered with the varied choices of colored indicator lights and colored print lines designated for gamma and neutron alarms. In addition, second-party software that changes the alarm color scheme may also have been installed. Furthermore, no provision exists for the color blind or to provide work stations with only black ink on alarm printouts. These inconsistencies and confusing setups could inadvertently cause a misinterpretation of the alarm, resulting in the potential release of a radiological hazard into a sovereign country. These issues are discussed, and a proposed solution is offered.

  15. Mobile Portal Implementation Strategy

    DEFF Research Database (Denmark)

    Gao, Ping; Damsgaard, Jan

    2005-01-01

    Mobile portal plays an important role in mobile commerce market. Current literature focuses on static analysis on the value chain of mobile portals. This article provides a dynamic perspective on mobile portal strategy. Drawing upon network economics, we describe mobile portal implementation...... as a fourphase process. In different phase, a portal provider has various challenges to overcome and adopt diverse strategies, and correspondingly the regulator has different foci. The conceptual framework proposed in this article offers a basis for further analyses on the market dynamics of mobile commerce......, and can be generalized to studying other networked technologies...

  16. The feasible study of vasodilators in portal vein targeting infusion for treating portal hypertension

    International Nuclear Information System (INIS)

    Wu Hanping; Liang Huiming; Zheng Chuansheng; Feng Gansheng

    2002-01-01

    Objective: To find out the ideal portal vein tar getting injection routes for portal hypertension treatment. Methods: 28 cirrhotic rat models with portal hypertension induced by CCl 4 were divided into 4 groups: inferior caval vein injection group, portal vein injection group, hepatic artery injection group, spleen injection group. The changes in portal vein pressure (PVP), inferior caval vein pressure (ICVP), mean artery pressure (MAP) and heart rate (HR) were monitored before and after prazosin injection. Results: After intra-portal, intra-hepatic arterial or spleen injection of prazosin, larger decrease in PVP and lesser effects on MAP than intravenous injection had been induced. The effect on HR showed no difference among these four groups. Conclusions: Hepatic artery and spleen prazosin administration have the same advantages on treatment of portal hypertension as those of intra-portal infusion, that is the greater decrease on portal vein pressure, the lesser effects on systemic hemodynamics. Vasodilation drugs for hepatic artery infusion through percutaneous port catheter system by hepatic artery implantation would be an ideal method for portal hypertension treatment

  17. LHCb : The DIRAC Web Portal 2.0

    CERN Multimedia

    Mathe, Zoltan; Lazovsky, N; Stagni, Federico

    2015-01-01

    For many years the DIRAC interware (Distributed Infrastructure with Remote Agent Control) has had a web interface, allowing the users to monitor DIRAC activities and also interact with the system. Since then many new web technologies have emerged, therefore a redesign and a new implementation of the DIRAC Web portal were necessary, taking into account the lessons learnt using the old portal. These new technologies allowed to build a more compact and more responsive web interface that is robust and that enables users to have more control over the whole system while keeping a simple interface. The framework provides a large set of "applications", each of which can be used for interacting with various parts of the system. Communities can also create their own set of personalised web applications, and can easily extend already existing web applications with a minimal effort. Each user can configure and personalise the view for each application and save it using the DIRAC User Profile service as RESTful state prov...

  18. Applications of portals in the energetic sector; Aplicaciones de portales en el sector energetico

    Energy Technology Data Exchange (ETDEWEB)

    Santos Dominguez, Martin; Arroyo Figueroa, Gustavo [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2000-07-01

    An operative portal joins the applications, contents and services of the company in a single page of Intranet such way that promises to change deeply the information technology in the next years. The corporative portals will change what people visualize in the screen of their computer at the beginning of every working day. Unlike seeing the network (Web) only with pages of language of hypertext bearing (HTML), the corporative portal acts as a gate between Internet and the private networks. This article presents a general vision of the benefits of the corporative portals, the existing technologies and the potential markets. [Spanish] Un portal operativo une las aplicaciones, contenidos y servicios de la empresa en una sola pagina de Intranet, de tal forma que promete cambiar, profundamente la tecnologia de la informacion en los proximos anos. Los portales corporativos cambiaran lo que la gente visualiza en la pantalla de su computadora al comienzo de cada dia de trabajo. A diferencia de ver la red (Web) solo con paginas de lenguaje de marcacion de hipertexto (HTML), el portal corporativo actua como compuerta entre Internet y las redes privadas. Este articulo presenta una vision general de los beneficios de los portales corporativos, las tecnologias y los mercados potenciales existentes.

  19. DEVELOPMENT OF EDUCATION AND INFORMATION PORTAL OF PHYSICS ACADEMIC COURSE: WEB DESIGN FEATURES

    Directory of Open Access Journals (Sweden)

    Іryna A. Slipukhina

    2018-04-01

    Full Text Available The purpose of this article is to present the main components and features of designing an educational and informational portal for students. Selection of personal trajectory is realized through the use of personal account, which includes electronic laboratory reports, information materials on studying progress, means of communication with a teacher, etc. The created portal allows the administrator to easily monitor and check laboratory reports, keep an e-journal with grades. To develop the website design, functional modules and components, the Adobe Photoshop ™ environment was used, as well as the HTML and CSS layout of the web portal. The modern Bootstrap technology was applied to adapt the web page interface. The didactic opportunities of using this portal as a part of personalization process in teaching physics were considered.

  20. Information Portal Costs and Benefits

    Directory of Open Access Journals (Sweden)

    Lorena BATAGAN

    2006-01-01

    Full Text Available All transformations of our society are the product of the large use of Information and Communications Technologies (ICT and Internet. ICT are technologies which facilitate communication, processing, and transmission of information by electronic means. It is very important to use the new technologies to the correct value because this determinate an increase of global benefits. Portal provides a consistent way to select, evaluate, prioritize and plan the right information. In research we point the important costs and benefits for an informational portal. The portal for local administrative determinate for citizens the access to information of interest and on the other hand make easier for employer to manage the documents.

  1. Integrated neutron/gamma-ray portal monitors for nuclear safeguards

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1994-01-01

    Radiation monitoring is one nuclear-safeguards measure used to protect against the theft of special nuclear materials (SNM) by pedestrians departing from SNM access areas. The integrated neutron/gamma-ray portal monitor is an ideal radiation monitor for the task when the SNM is plutonium. It achieves high sensitivity for detecting both bare and shielded plutonium by combining two types of radiation detector. One type is a neutron-chamber detector, comprising a large, hollow, neutron moderator that contains a single thermal-neutron proportional counter. The entrance wall of each chamber is thin to admit slow neutrons from plutonium contained in a moderating shield, while the other walls are thick to moderate fast neutrons from bare or lead-shielded plutonium so that they can be detected. The other type of detector is a plastic scintillator that is primarily for detecting gamma rays from small amounts of unshielded plutonium. The two types of detector are easily integrated by making scintillators part of the thick back wall of each neutron chamber or by inserting them into each chamber void. The authors compared the influence of the two methods of integration on detecting neutrons and gamma rays, and they examined the effectiveness of other design factors and the methods for signal detection as well

  2. Analysis of the Organ Offers Received From European Union Countries Before and After the Introduction of a Dedicated Information Technology Portal: The COORENOR/FOEDUS Portal.

    Science.gov (United States)

    Peritore, D; Rizzato, L; Di Ciaccio, P; Trapani, S; Carella, C; Oliveti, A; Rizzo, A; Nanni Costa, A

    2017-05-01

    To optimize the use of nontransplantable organs in their own territory, the European Commission, as part of a project led by Italy, has promoted the use of an information technology (IT) portal, the COORENOR portal, developed by the Czech Republic in 2012, which evolved to become FOEDUS in 2015. To evaluate the impact of the portal on our reality, we analyzed the number and type of offers received and organs imported in the previous 48 months (period A) as well as the 48 months after the introduction of the portal (period B). We also examined the origin and the offer mode. The offers received were 404 and 753, respectively, in the two periods, with 315 (41.8%) organs received through the portal. The organs transplanted were 53 and 64, respectively, in the two periods; 20 (31.2%) were sent through the portal. The most commonly offered organs are lungs (36.7% and 29.3% of offers in periods A and B, respectively). The most transplanted organ is the liver (59.4% and 45% of transplants in periods A and B, respectively). The use of the portal has gradually increased, growing from 16.4% of the offer mode in 2012 to 84.7% in 2016. The increase of offers related to the increase of donations and the attitude to the sharing of resources has determined an increase of 19.2% of total transplants, especially for certain types such as pediatric transplants. The portal, ensuring speed and simultaneity of offer, real time sharing of information and transparency of allocation, is also used for trade in the International Partnership Agreements. Therefore, transplants have been conditioned by the existing agreements with Greece, Malta, and the countries of the South Transplant Alliance. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Combating the counterfeits with web portal technology

    Science.gov (United States)

    Ting, S. L.; Ip, W. H.

    2015-10-01

    Due to the globalisation of counterfeiting activities, the penetration of fake products in open market is growing. So far, the technologies to combat counterfeiting are mostly applied to high-value products (e.g. premium wine and branded handbags); however, in the medium- and low-value products' perspective, there is no secure way for consumers to identify whether the purchased items are genuine or not. To address the counterfeiting problems effectively, a platform for identifying authenticated products and promoting anti-counterfeit activities is very important. The aim of this paper is to design and develop an anti-counterfeit platform which includes two functions: providing customers a secure network to ascertain the genuineness of their purchased product and increasing public awareness of the current counterfeit problems and updated anti-counterfeit solutions. By combining these two functions, it enables public to fight against fake and beware of counterfeit. Results of adopting portal technology in anti-counterfeiting show high accuracy in product checking and improved creditability. This reveals that the applicability and advantage of the proposed methodology are satisfactory.

  4. Time Series Evaluation of Portal Monitor Data

    International Nuclear Information System (INIS)

    Robinson, Sean M.; Bender, Sarah E.; Lopresti, Charles A.; Woodring, Mitchell L.

    2008-01-01

    Radiation portal monitors screen cargo and personal vehicle traffic at international border crossings to detect and interdict illicit sources which may be present in the commerce stream. One difficulty faced by RPM systems is the prospect of false alarms, or undesired alarms due to background fluctuation, or Naturally-Occurring Radioactive Material (NORM) sources in the commerce stream. In general, NORM alarms represent a significant fraction of the nuisance alarms at international border crossings, particularly with Polyvinyl-Toluene (PVT) RPM detectors, which have only very weak spectral differentiation capability. With PVT detectors, the majority of detected photon events fall within the Compton continuum of the material, allowing for very little spectral information to be preserved (1). Previous work has shown that these detectors can be used for limited spectroscopy, utilizing around 8 spectral bins to further differentiate some NORM and other nuisance sources (2). NaI based systems achieve much more detailed spectral resolution from each measurement of a source, but still combine all measurements over a vehicle's occupancy in order to arrive at a spectrum to be analyzed

  5. From EGEE Operations Portal towards EGI Operations Portal

    Science.gov (United States)

    Cordier, Hélène; L'Orphelin, Cyril; Reynaud, Sylvain; Lequeux, Olivier; Loikkanen, Sinikka; Veyre, Pierre

    Grid operators in EGEE have been using a dedicated dashboard as their central operational tool, stable and scalable for the last 5 years despite continuous upgrade from specifications by users, monitoring tools or data providers. In EGEE-III, recent regionalisation of operations led the Operations Portal developers to conceive a standalone instance of this tool. We will see how the dashboard reorganization paved the way for the re-engineering of the portal itself. The outcome is an easily deployable package customized with relevant information sources and specific decentralized operational requirements. This package is composed of a generic and scalable data access mechanism, Lavoisier; a renowned php framework for configuration flexibility, Symfony and a MySQL database. VO life cycle and operational information, EGEE broadcast and Downtime notifications are next for the major reorganization until all other key features of the Operations Portal are migrated to the framework. Features specifications will be sketched at the same time to adapt to EGI requirements and to upgrade. Future work on feature regionalisation, on new advanced features or strategy planning will be tracked in EGI- Inspire through the Operations Tools Advisory Group, OTAG, where all users, customers and third parties of the Operations Portal are represented from January 2010.

  6. ELECTRONIC COMMERCE PORTAL

    OpenAIRE

    Georgeta Soava

    2011-01-01

    Today companies are faced with the need to exploit technology changing computer environments, in order to improve customer satisfaction and reduce costs. A successful approach to electronic portals is an effective demonstration of the new ways of relating to the client. The objectives that we have considered for the realization of e-commerce portal can be summarized as follows: structured communication, effective collaboration, complet and closed circuit of orders and deliveries, inventory op...

  7. Comparing a recursive digital filter with the moving-average and sequential probability-ratio detection methods for SNM portal monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1993-01-01

    The author compared a recursive digital filter proposed as a detection method for French special nuclear material monitors with the author's detection methods, which employ a moving-average scaler or a sequential probability-ratio test. Each of these nine test subjects repeatedly carried a test source through a walk-through portal monitor that had the same nuisance-alarm rate with each method. He found that the average detection probability for the test source is also the same for each method. However, the recursive digital filter may have on drawback: its exponentially decreasing response to past radiation intensity prolongs the impact of any interference from radiation sources of radiation-producing machinery. He also examined the influence of each test subject on the monitor's operation by measuring individual attenuation factors for background and source radiation, then ranked the subjects' attenuation factors against their individual probabilities for detecting the test source. The one inconsistent ranking was probably caused by that subject's unusually long stride when passing through the portal

  8. TUX-INTERO: A Portal for secure interoperation of Grids

    OpenAIRE

    Shashi Bhanwar; Seema Bawa

    2010-01-01

    In this paper, we propose TUX-INTERO - a portlet-based Grid portal for integrating existing grid technologies under a common interface and providing reliable services to the users. We have developed a prototype of TUX-INTERO - a grid portal using portlet technology. The paper presents design and development of TUXINTERO. The requirements for the portal, its design and technology choices lead to the utilization of Globus Toolkit as middleware for connecting global resources, SUN N1 GE6 and Con...

  9. Energy Innovation Portal Brings DOE Technologies to the Market (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2011-10-01

    For venture capitalists, energy entrepreneurs, and industry veterans, finding the right renewable energy or energy efficiency solution used to be like looking for a needle in a haystack. Now, a searchable treasure trove of innovative U.S. Department of Energy (DOE) technologies is available. Created by the National Renewable Energy Laboratory (NREL), the online Energy Innovation Portal helps businesses and entrepreneurs access the intellectual property of DOE's 17 national laboratories and other research partners.

  10. The Learning Portal

    Science.gov (United States)

    Staudt, Carolyn; Hanzlick-Burton, Camden; Williamson, Carol; McIntyre, Cynthia

    2015-01-01

    The Innovative Technology in Science Inquiry (ITSI) project is a learning portal with hundreds of free, customizable science, math, and engineering activities funded by the National Science Foundation at the Concord Consortium, a nonprofit research and development organization dedicated to transforming education through technology. The project…

  11. Technology monitoring; Technologie-Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Eicher, H.; Rigassi, R. [Eicher und Pauli AG, Liestal (Switzerland); Ott, W. [Econcept AG, Zuerich (Switzerland)

    2003-07-01

    This study made for the Swiss Federal Office of Energy (SFOE) examines ways of systematically monitoring energy technology development and the cost of such technologies in order to pave the way to a basis for judging the economic development of new energy technologies. Initial results of a survey of the past development of these technologies are presented and estimates are made of future developments in the areas of motor-based combined heat and power systems, fuel-cell heating units for single-family homes and apartment buildings, air/water heat pumps for new housing projects and high-performance thermal insulation. The methodology used for the monitoring and analysis of the various technologies is described. Tables and diagrams illustrate the present situation and development potential of various fields of technology.

  12. R2 Water Quality Portal Monitoring Stations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on...

  13. The NUCLEONICA Nuclear Science Portal

    International Nuclear Information System (INIS)

    Magill, Joseph; Dreher, Raymond

    2009-01-01

    NUCLEONICA (www.nucleonica.net) is a new nuclear science web portal which provides a customisable, integrated environment and collaboration platform using the latest internet 'Web 2.0' technology. NUCLEONICA is aimed at professionals, academics and students working in nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. A unique feature of the portal is the wide range of user friendly web-based nuclear science applications. The portal is also ideal for education and training purposes and as a knowledge management platform to preserve nuclear knowledge built up over many decades.

  14. NASA Sea Level Change Portal - It not just another portal site

    Science.gov (United States)

    Huang, T.; Quach, N.; Abercrombie, S. P.; Boening, C.; Brennan, H. P.; Gill, K. M.; Greguska, F. R., III; Jackson, R.; Larour, E. Y.; Shaftel, H.; Tenenbaum, L. F.; Zlotnicki, V.; Moore, B.; Moore, J.; Boeck, A.

    2017-12-01

    The NASA Sea Level Change Portal (https://sealevel.nasa.gov) is designed as a "one-stop" source for current sea level change information, including interactive tools for accessing and viewing regional data, a virtual dashboard of sea level indicators, and ongoing updates through a suite of editorial products that include content articles, graphics, videos, and animations. With increasing global temperatures warming the ocean and melting ice sheets and glaciers, there is an immediate need both for accelerating sea level change research and for making this research accessible to scientists in disparate discipline, to the general public, to policy makers and business. The immersive and innovative NASA portal debuted at the 2015 AGU attracts thousands of daily visitors and over 30K followers on Facebook®. Behind its intuitive interface is an extensible architecture that integrates site contents, data for various sources, visualization, horizontal-scale geospatial data analytic technology (called NEXUS), and an interactive 3D simulation platform (called the Virtual Earth System Laboratory). We will present an overview of our NASA portal and some of our architectural decisions along with discussion on our open-source, cloud-based data analytic technology that enables on-the-fly analysis of heterogeneous data.

  15. Elimination of quarterly urinalysis of radiation workers based on detection capability of portal monitors for internal contamination

    International Nuclear Information System (INIS)

    Ramanuja, Jayalakshmi

    2012-01-01

    Covidien is a radiopharmaceutical manufacturing company in Missouri, USA. The facility produces radionuclides for diagnostic and therapeutic use. The radionuclides of interest, 123 I, 67 Ga, 99 Mo, 99m Tc, 201 Tl, 111 In, and 131 I are fairly short lived with the exception of 51 Cr. The operating license document for the company mandated quarterly urinalysis (bioassay) of all radiation workers in the facility. This was labor intensive and did not enhance the quality of radiation protection program. Nuclear Regulatory Commission (NRC) required a technical basis to prove that there was no compromise in the radiological safety and accurate dose assessment in the event of internal contamination of radiation workers if quarterly urinalysis was discontinued. Measurements in a phantom, gamma spectroscopy analysis, as well as calculations showed that there was no need to perform quarterly urinalysis and that portal monitors and other radiological controls were sufficient to detect any chronic or acute intake of radioactivity by radiation workers. Technical evaluation showed Portal monitors can detect an Effective Dose Equivalent of 0.1 mSv (10 mrem) in a year. NRC allowed revision of operating license document and operating procedures to discontinue quarterly urinalysis. (author)

  16. Prospective clinical evaluation of an electronic portal imaging device

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Graham, Mary V.; Bosch, Walter R.; Wong, John; Gerber, Russell L.; Cheng, Abel; Tinger, Alfred; Valicenti, Richard K.

    1996-01-01

    Purpose: To determine whether the clinical implementation of an electronic portal imaging device can improve the precision of daily external beam radiotherapy. Methods and Materials: In 1991, an electronic portal imaging device was installed on a dual energy linear accelerator in our clinic. After training the radiotherapy technologists in the acquisition and evaluation of portal images, we performed a randomized study to determine whether online observation, interruption, and intervention would result in more precise daily setup. The patients were randomized to one of two groups: those whose treatments were actively monitored by the radiotherapy technologists and those that were imaged but not monitored. The treating technologists were instructed to correct the following treatment errors: (a) field placement error (FPE) > 1 cm; (b) incorrect block; (c) incorrect collimator setting; (d) absent customized block. Time of treatment delivery was recorded by our patient tracking and billing computers and compared to a matched set of patients not participating in the study. After the patients radiation therapy course was completed, an offline analysis of the patient setup error was planned. Results: Thirty-two patients were treated to 34 anatomical sites in this study. In 893 treatment sessions, 1,873 fields were treated (1,089 fields monitored and 794 fields unmonitored). Ninety percent of the treated fields had at least one image stored for offline analysis. Eighty-seven percent of these images were analyzed offline. Of the 1,011 fields imaged in the monitored arm, only 14 (1.4%) had an intervention recorded by the technologist. Despite infrequent online intervention, offline analysis demonstrated that the incidence of FPE > 10 mm in the monitored and unmonitored groups was 56 out of 881 (6.1%) and 95 out of 595 (11.2%), respectively; p 10 mm was confined to the pelvic fields. The time to treat patients in this study was 10.78 min (monitored) and 10.10 min (unmonitored

  17. Advances in the treatment of portal hypertension in cirrhosis.

    Science.gov (United States)

    Kimer, N; Wiese, S; Mo, S; Møller, S; Bendtsen, F

    2016-08-01

    Non-selective beta-blockers and handling of esophageal varices has been key elements in the treatment of portal hypertension in recent decades. Liver vein catheterization has been essential in diagnosis and monitoring of portal hypertension, but ongoing needs for noninvasive tools has led to research in areas of both biomarkers, and transient elastography, which displays promising results in discerning clinically significant portal hypertension. Novel research into the areas of hepatic stellate cell function and the dynamic components of portal hypertension has revealed promising areas of treatment modalities, targeting intestinal decontamination, angiogenesis, inflammation and oxidative stress. Future studies may reveal if these initiatives lead to developments of new drugs for treatment of portal hypertension.

  18. Advances in the treatment of portal hypertension in cirrhosis

    DEFF Research Database (Denmark)

    Kimer, Nina; Wiese, S; Mo, S S

    2016-01-01

    Non-selective beta-blockers and handling of esophageal varices has been key elements in the treatment of portal hypertension in recent decades. Liver vein catheterization has been essential in diagnosis and monitoring of portal hypertension, but ongoing needs for noninvasive tools has led...... to research in areas of both biomarkers, and transient elastography, which displays promising results in discerning clinically significant portal hypertension. Novel research into the areas of hepatic stellate cell function and the dynamic components of portal hypertension has revealed promising areas...... of treatment modalities, targeting intestinal decontamination, angiogenesis, inflammation and oxidative stress. Future studies may reveal if these initiatives lead to developments of new drugs for treatment of portal hypertension....

  19. Knowledge portal: a tool to capture university requirements

    Science.gov (United States)

    Mansourvar, Marjan; Binti Mohd Yasin, Norizan

    2011-10-01

    New technologies, especially, the Internet have made a huge impact on knowledge management and information dissemination in education. The web portal as a knowledge management system is very popular topics in many organizations including universities. Generally, a web portal defines as a gateway to online network accessible resources through the intranet, extranet or Internet. This study develops a knowledge portal for the students in the Faculty of Computer Science and Information Technology (FCSIT), University of Malaya (UM). The goals of this portal are to provide information for the students to help them to choose the right courses and major that are relevant to their intended future jobs or career in IT. A quantitative approach used as the selected method for this research. Quantitative method provides an easy and useful way to collect data from a large sample population.

  20. Design of dual-road transportable portal monitoring system for visible light and gamma-ray imaging

    Science.gov (United States)

    Karnowski, Thomas P.; Cunningham, Mark F.; Goddard, James S.; Cheriyadat, Anil M.; Hornback, Donald E.; Fabris, Lorenzo; Kerekes, Ryan A.; Ziock, Klaus-Peter; Bradley, E. Craig; Chesser, J.; Marchant, W.

    2010-04-01

    The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third "alignment" camera for motion compensation and are mounted on a 50' deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

  1. Design of Dual-Road Transportable Portal Monitoring System for Visible Light and Gamma-Ray Imaging

    International Nuclear Information System (INIS)

    Karnowski, Thomas Paul; Cunningham, Mark F.; Goddard, James Samuel Jr.; Cheriyadat, Anil M.; Hornback, Donald Eric; Fabris, Lorenzo; Kerekes, Ryan A.; Ziock, Klaus-Peter; Bradley, Eric Craig; Chesser, Joel B.; Marchant, William

    2010-01-01

    The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third alignment camera for motion compensation and are mounted on a 50 deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

  2. High Touch and High Tech (HT2) Proposal: Transforming Patient Engagement Throughout the Continuum of Care by Engaging Patients with Portal Technology at the Bedside.

    Science.gov (United States)

    McAlearney, Ann Scheck; Sieck, Cynthia J; Hefner, Jennifer L; Aldrich, Alison M; Walker, Daniel M; Rizer, Milisa K; Moffatt-Bruce, Susan D; Huerta, Timothy R

    2016-11-29

    For patients with complex care needs, engagement in disease management activities is critical. Chronic illnesses touch almost every person in the United States. The costs are real, personal, and pervasive. In response, patients often seek tools to help them manage their health. Patient portals, personal health records tethered to an electronic health record, show promise as tools that patients value and that can improve health. Although patient portals currently focus on the outpatient experience, the Ohio State University Wexner Medical Center (OSUWMC) has deployed a portal designed specifically for the inpatient experience that is connected to the ambulatory patient portal available after discharge. While this inpatient technology is in active use at only one other hospital in the United States, health care facilities are currently investing in infrastructure necessary to support large-scale deployment. Times of acute crisis such as hospitalization may increase a patient's focus on his/her health. During this time, patients may be more engaged with their care and especially interested in using tools to manage their health after discharge. Evidence shows that enhanced patient self-management can lead to better control of chronic illness. Patient portals may serve as a mechanism to facilitate increased engagement. The specific aims of our study are (1) to investigate the independent effects of providing both High Tech and High Touch interventions on patient-reported outcomes at discharge, including patients' self-efficacy for managing chronic conditions and satisfaction with care; and (2) to conduct a mixed-methods analysis to determine how providing patients with access to MyChart Bedside (MCB, High Tech) and training/education on patient portals, and MyChart Ambulatory (MCA, High Touch) will influence engagement with the patient portal and relate to longer-term outcomes. Our proposed 4-year study uses a mixed-methods research (MMR) approach to evaluate a

  3. Per-rectal portal scintigraphy in chronic liver diseases

    International Nuclear Information System (INIS)

    Frusciante, V.; Barbano, F.; Btuno, M.; Facciorusso, D.; Tonti, P.; Giacobbe, A.; Andriulli, A.; Vettori, P.G.P.

    1993-01-01

    Portal circulation has been evaluated by per-rectal portal scintigraphy in 21 controls and in 30 pts affected by chronic liver diseases. Tc99m-pertechnetate (10 mci) was given through a Nelaton's catheter in the upper rectum; a per-rectal portal shunt index (SI) was calculated. A relevant overlap is evident between controls and CHP pts; no overlap exists between controls and B or C graded cirrhosis. We conclude that the technique may be suggested to monitor the course of chronic liver diseases and different therapeutic regimens. (orig.) [de

  4. Security Aspects for Business Solution Development on Portal Technology

    OpenAIRE

    Ovidiu R?DU??; Adrian MUNTEANU

    2012-01-01

    In the scope of portal development, in order to talk about security issues, concerns, and solutions, it is necessary to define a few terms: authentication, authorization, Single Sign-On (SSO), confidentiality, integrity, and non-repudiation. Focusing on the scope of what the portal developer and designer need to know, below it will be explained these concepts, considering it is important to define and make a brief analysis of these terms for understanding of achieving the security goals.

  5. Monitoring Technology Meets Care Work

    DEFF Research Database (Denmark)

    Kanstrup, Anne Marie; Bygholm, Ann

    2015-01-01

    's ability to meet the complexity of care work. Understanding intersectional challenges between these care technologies and care work is fundamental to improve design and use of health informatics. In this paper we present an analysis of interaction challenges between a wet-sensor at the task of monitoring......Monitoring technology, especially sensor-based technology, is increasingly taken into use in care work. Despite the simplicity of these technologies – aimed to automate what appear as mundane monitoring tasks – recent research has identified major challenges primarily related to the technology...... wet beds at a nursing home. The analysis identifies the multifaceted nature of monitoring work and the intricacy of integrating sensor technology into the complex knowledge system of monitoring work....

  6. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. This problem is compounded by the fact that the commercially available EPIDs have mechanical slop and do not deploy to exactly the same position repeatedly. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the difficulties, many image registration techniques such as interactive techniques, landmark-based techniques, contrast-based techniques, and hybrid techniques have been developed to detect errors in patient positioning. The advantages and disadvantages of these various techniques will be discussed. Clinical use of portal imaging systems has included the use of static localisation and verification images, the use of 'movie' sequences (sequences of images acquired during one irradiation) and the use of 'time-lapse' sequences of images acquired during consecutive treatments, which demonstrate the variability in patient set-up over a full course of therapy. Possibly the most contentious issue is how to best make use of the information provided the portal images. Philosophies have ranged between intervening in every treatment, to intervening only occasionally, or to identifying patients who would benefit from smaller treatment margins and modifying the treatment plan part way through the course of treatment. Conclusions: While great improvements in portal imaging technology have been made, in the future more effort will to be directed towards improving image quality, and integrating and automating the various steps in the image registration process. In addition, other uses for portal imaging

  7. ASH External Web Portal (External Portal) -

    Data.gov (United States)

    Department of Transportation — The ASH External Web Portal is a web-based portal that provides single sign-on functionality, making the web portal a single location from which to be authenticated...

  8. Computer Modeling of Radiation Portal Monitors for Homeland Security Applications

    International Nuclear Information System (INIS)

    Pagh, Richard T.; Kouzes, Richard T.; McConn, Ronald J.; Robinson, Sean M.; Schweppe, John E.; Siciliano, Edward R.

    2005-01-01

    Radiation Portal Monitors (RPMs) are currently being used at our nation's borders to detect potential nuclear threats. At the Pacific Northwest National Laboratory (PNNL), realistic computer models of RPMs are being developed to simulate the screening of vehicles and cargo. Detailed models of the detection equipment, vehicles, cargo containers, cargos, and radioactive sources are being used to determine the optimal configuration of detectors. These models can also be used to support work to optimize alarming algorithms so that they maximize sensitivity for items of interest while minimizing nuisance alarms triggered by legitimate radioactive material in the commerce stream. Proposed next-generation equipment is also being modeled to quantify performance and capability improvements to detect potential nuclear threats. A discussion of the methodology used to perform computer modeling for RPMs will be provided. In addition, the efforts to validate models used to perform these scenario analyses will be described. Finally, areas where improved modeling capability is needed will be discussed as a guide to future development efforts

  9. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis.

    Science.gov (United States)

    Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo

    2005-06-07

    To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

  10. A Look at Success for Data Portals (Invited)

    Science.gov (United States)

    White, C. E.

    2013-12-01

    As a member of Esri's Geoportal Server team for the past six years, I have been involved in hundreds of customer portal, geoportal, and spatial data infrastructure implementations. Our team's goal for each implementation is - of course- for it to be successful. A successful data portal can be defined by a number of indicators. The foremost measure of success is that the target end users are able to easily find and access data that meets their needs. Other indicators are effectiveness of the user interface, interoperability mechanisms to enhance discoverability and usability across contexts, compliance with data sharing mandates, extendibility/portability of the system as technology evolves, and staff expertise to maintain the system. Further, some data portals have not only been successful by these measures but have also challenged and expanded the state of the art in the areas of discovery, access, and managing data. This talk will address models, principles, and best practices for deploying data portals that are successful by these measures, identify examples of excellence in the field, and discuss upcoming advances in portal technology to support scientists in sharing their work.

  11. Passive nuclear material detection in a personnel portal

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Eaton, M.J.

    1979-01-01

    The concepts employed in the development of gamma-ray and neutron detection systems for a special nuclear materials booth portal monitor are described. The portal is designed for unattended use in detecting diversion by a technically sophisticated adversary and has possible application to International Atomic Energy Agency safeguards of a fast critical assembly facility. Preliminary evaluation results are given and plans for further parameter studies are noted

  12. Designing User-Centric Patient Portals: Clinician and Patients' Uses and Gratifications.

    Science.gov (United States)

    Alpert, Jordan M; Krist, Alex H; Aycock, Rebecca A; Kreps, Gary L

    2017-03-01

    Legislation mandates that clinicians make patients' medical information available digitally. This has resulted in hurriedly installing patient portals that do not fully meet the needs of patients or clinicians. This study examined a specific portal, MyPreventiveCare (MPC), a patient-centered portal designed to promote preventive care to consumers, to elicit recommendations from patients and clinicians about how it could be more beneficial by uncovering their uses and gratifications (U&G). In-depth interviews with 31 patients and two clinician focus groups were conducted. Multiple methods were utilized, such as grounded theory coding to develop themes and content analysis to classify responses according to the U&G framework. Four main categories emerged that users desire to be included in health portals: integration with technology (27%), coordination of care (27%), incorporation of lifestyle (26%), and increased control (20%). Additional analysis revealed that health portals are mainly utilized to fulfill cognitive and affective needs, with over 80% of recommendations related to the U&G categories of cognitive and affective needs. Cognitive (60%), affective (21%), social integrative (10%), personal integrative (9%), and tension release (0%). Portals will continue to evolve and become important health communication tools if they address the user's perspective and are inclusive of new technological advances. Specifically, portals must become more user centric and incorporate aspects of the patients' lifestyle and integrate health information technology.

  13. Global Mercury Observatory System Land-based Monitoring Data Portal

    Data.gov (United States)

    U.S. Environmental Protection Agency — Global Mercury Observation System On-line Data Portal. This dataset is associated with the following publication: Carbone, F., A. Bruno, A. Naccarato, F. De Simone,...

  14. Strength analysis of support structure and characterization of prototype imaging portal monitor

    International Nuclear Information System (INIS)

    Khairul Handono; Alvano Yulian; Muhammad Awwaluddin

    2014-01-01

    The mechanical systems analysis and testing of control systems and data acquisition the prototype Portal Imaging Monitor Container has been conducted. Analysis of the mechanical system includes support holder important to maintain continuity of operations. While the analysis of the data acquisition system and electrically system done on the conveyor drive motor power supply. The purpose of the analysis and characterization for design improvements. The process of static analysis is done through a conveyor frame structure simulation in ANSYS 1.4 software. In the data acquisition system and the electrical system has been tested. From the results of the mechanical analysis showed that the design created has met the criteria of security and safety. While the data acquisition system testing the system can display the data through the Internet with either. (author)

  15. ERNIE performance with TSA portals Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Labov, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2018-01-05

    This project extends the “Enhanced Radiological Nuclear Inspection and Evaluation” (ERNIE) system developed with CBP and DNDO to improve performance of PVT-based Radiation Portal Monitors (RPMs). ERNIE was designed to be used with any RPM system. The first implementation was with the SAIC (Leidos) RPM-8 systems. In this project, we are demonstrating how effective the ERNIE approach can be when applied to the VM250 TSA portals used in NSDD programs. Part of the challenge in adapting ERNIE to handle VM250 portals is the lack of gamma spectral information. We report here on the first results showing how the ERNIE analysis can improve analysis of measurements with the VM250 RPMs.

  16. Software engineering knowledge at your fingertips: Experiences with a software engineering-portal

    OpenAIRE

    Punter, T.; Kalmar, R.

    2003-01-01

    In order to keep up the pace with technology development, knowledge on Software Engineering (SE) methods, techniques, and tools is required. For an effective and efficient knowledge transfer, especially Small and Medium-sized Enterprises (SMEs) might benefit from Software Engineering Portals (SE-Portals). This paper provides an analysis of SE-Portals by distinguishing two types: 1) the Knowledge Portal and 2) the Knowledge & Community Portal. On behalf of the analysis we conclude that most SE...

  17. Designing User-Centric Patient Portals: Clinician and Patients' Uses and Gratifications

    Science.gov (United States)

    Krist, Alex H.; Aycock, Rebecca A.; Kreps, Gary L.

    2017-01-01

    Abstract Background: Legislation mandates that clinicians make patients' medical information available digitally. This has resulted in hurriedly installing patient portals that do not fully meet the needs of patients or clinicians. This study examined a specific portal, MyPreventiveCare (MPC), a patient-centered portal designed to promote preventive care to consumers, to elicit recommendations from patients and clinicians about how it could be more beneficial by uncovering their uses and gratifications (U&G). Materials and Methods: In-depth interviews with 31 patients and two clinician focus groups were conducted. Multiple methods were utilized, such as grounded theory coding to develop themes and content analysis to classify responses according to the U&G framework. Results: Four main categories emerged that users desire to be included in health portals: integration with technology (27%), coordination of care (27%), incorporation of lifestyle (26%), and increased control (20%). Additional analysis revealed that health portals are mainly utilized to fulfill cognitive and affective needs, with over 80% of recommendations related to the U&G categories of cognitive and affective needs. Cognitive (60%), affective (21%), social integrative (10%), personal integrative (9%), and tension release (0%). Conclusions: Portals will continue to evolve and become important health communication tools if they address the user's perspective and are inclusive of new technological advances. Specifically, portals must become more user centric and incorporate aspects of the patients' lifestyle and integrate health information technology. PMID:27333468

  18. Improving diabetes management with a patient portal: a qualitative study of diabetes self-management portal.

    Science.gov (United States)

    Urowitz, Sara; Wiljer, David; Dupak, Kourtney; Kuehner, Zachary; Leonard, Kevin; Lovrics, Emily; Picton, Peter; Seto, Emily; Cafazzo, Joe

    2012-11-30

    Effective management and care of diabetes is crucial to reducing associated risks such as heart disease and kidney failure. With increasing access and use of the Internet, online chronic disease management is being explored as a means of providing patients with support and the necessary tools to monitor and manage their disease. The objective of our study was to evaluate the experience of patients and providers using an online diabetes management portal for patients. Participants were recruited from a large sample population of 887 for a follow-up questionnaire to be completed after 6 months of using the patient portal. Participants were presented with the option to participate in an additional interview and, if the participant agreed, a time and date was scheduled for the interview. A 5-item, open-ended questionnaire was used to capture providers' opinions of the patient portal. Providers included general practitioners (GPs), nurses, nurse practitioners (NPs), dieticians, diabetes educators (DECs), and other clinical staff. A total of 854 patients were consented for the questionnaire. Seventeen (8 male, 9 female) patients agreed to participate in a telephone interview. Sixty-four health care providers completed the five open-ended questions; however, an average of 48.2 responses were recorded per question. Four major themes were identified and will be discussed in this paper. These themes have been classified as: facilitators of disease management, barriers to portal use, patient-provider communication and relationship, and recommendations for portal improvements. This qualitative study shows that online chronic disease management portals increase patient access to information and engagement in their health care, but improvements in the portal itself may improve usability and reduce attrition. Furthermore, this study identifies a grey area that exists in the roles that GPs and AHPs should play in the facilitation of online disease management.

  19. Portal Vein Stenting for Portal Biliopathy with Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dongho, E-mail: mesentery@naver.com; Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center (Korea, Republic of); Lim, Seong Joo [Konyang University, Department of Radiology, College of Medicine, Konyang University Hospital (Korea, Republic of); Hwang, Jin Ho [Hallym University Sacred Heart Hospital, Department of Radiology (Korea, Republic of); Sinn, Dong Hyun [Sungkyunkwan University School of Medicine, Department of Medicine, Samsung Medical Center (Korea, Republic of)

    2016-04-15

    Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

  20. Technology monitoring in the CIEMAT

    International Nuclear Information System (INIS)

    Perez-Martinez, M.; Cuesta, M. J.; Crespi, S. N.; Cabrera, J. A.

    2008-01-01

    The CIEMAT Foresight and Technology Monitoring Unit focuses its activities on obtaining strategic information on future developments in the area of energy and environment that can be used for decision making by the centers management. In addition, it provides services to CIEMAT researchers and other external customers. In May 2007, the Asociacion Espanola de Normalizacion y Certificacion AENOR delivered to the CIEMAT the first Technology Monitoring System certificate granted in Spain as per standard UNE 166006:2006. This article describes the Units experience in the implementation process of the Technology Monitoring System and provides several examples of the way in which the Unit graphically represents the information analyzed in its Technology Monitoring Reports. (Author)

  1. A Web portal for CMS Grid job submission and management

    Energy Technology Data Exchange (ETDEWEB)

    Braun, David [Department of Physics, Purdue University, W. Lafayette, IN 47907 (United States); Neumeister, Norbert, E-mail: neumeist@purdue.ed [Rosen Center for Advanced Computing, Purdue University, W. Lafayette, IN 47907 (United States)

    2010-04-01

    We present a Web portal for CMS Grid submission and management. The portal is built using a JBoss application server. It has a three tier architecture; presentation, business logic and data. Bean based business logic interacts with the underlying Grid infrastructure and pre-existing external applications, while the presentation layer uses AJAX to offer an intuitive, functional interface to the back-end. Application data aggregating information from the portal as well as the external applications is persisted to the server memory cache and then to a backend database. We describe how the portal exploits standard, off-the-shelf commodity software together with existing Grid infrastructures in order to facilitate job submission and monitoring for the CMS collaboration. This paper describes the design, development, current functionality and plans for future enhancements of the portal.

  2. A Web portal for CMS Grid job submission and management

    International Nuclear Information System (INIS)

    Braun, David; Neumeister, Norbert

    2010-01-01

    We present a Web portal for CMS Grid submission and management. The portal is built using a JBoss application server. It has a three tier architecture; presentation, business logic and data. Bean based business logic interacts with the underlying Grid infrastructure and pre-existing external applications, while the presentation layer uses AJAX to offer an intuitive, functional interface to the back-end. Application data aggregating information from the portal as well as the external applications is persisted to the server memory cache and then to a backend database. We describe how the portal exploits standard, off-the-shelf commodity software together with existing Grid infrastructures in order to facilitate job submission and monitoring for the CMS collaboration. This paper describes the design, development, current functionality and plans for future enhancements of the portal.

  3. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. This problem is compounded by the fact that the commercially available EPIDs have mechanical slop and do not deploy to exactly the same position repeatedly. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the difficulties, many image registration techniques such as interactive techniques, landmark-based techniques, contrast-based techniques, and hybrid techniques have been developed to detect errors in patient positioning. The advantages and disadvantages of these various techniques will be discussed. Clinical use of portal imaging systems has included the use of static localisation and verification images, the use of 'movie' sequences (sequences of images acquired during one irradiation) and the use of 'time-lapse' sequences of images acquired during consecutive treatments, which demonstrate the variability in patient set-up over a full course of therapy. Possibly the most contentious issue is how to best make use of the information provided the portal images. Philosophies have ranged between intervening in every treatment, to intervening only occasionally, or to identifying patients who would benefit from smaller treatment margins and modifying the treatment plan part way through the course of treatment. While great improvements in portal imaging technology have

  4. Portal Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Hakan Demirci

    2016-01-01

    Full Text Available Portal vein thrombosis is an important cause of presinusoidal portal hypertension. Portal vein thrombosis commonly occurs in patient with cirrhosis, malignancy and prothrombotic states. Patients with acute portal vein thrombosis have immediate onset. Patients with chronic portal vein thrombosis have developed portal hypertension and cavernous portal transformation. Portal vein thrombosis is diagnosed with doppler ultrasound, computed tomography and magnetic resonance imaging. Therapy with low molecular weight heparin achieves recanalization in more than half of acute cases.

  5. Exploratory portals of research data in education

    Directory of Open Access Journals (Sweden)

    Di Blas Nicoletta

    2015-12-01

    Full Text Available This paper presents a powerful tool to enhance research in education: ‘exploratory portals’, supporting effective storage, sharing and exploration of large sets of research data. The workflow is the following: data are gathered by a research group; they are then classified according to a taxonomy (the one that best fits the group’s research interest; once uploaded in the portal, they can be ‘explored’ via a combination of faceted search (enriched by Boolean operators and data mining techniques. The system can thus answer in a few seconds to sophisticated user’s queries that otherwise would require hours; it can save a session’s results and materials for sharing with other scholars or for further investigation. The paper presents a case study of exploratory portal, dealing with data on (technology-based education. The portal has effectively been used by five different research groups, to run complex investigations of data about technology integration into schools.

  6. Patient portals and broadband internet inequality.

    Science.gov (United States)

    Perzynski, Adam T; Roach, Mary Joan; Shick, Sarah; Callahan, Bill; Gunzler, Douglas; Cebul, Randall; Kaelber, David C; Huml, Anne; Thornton, John Daryl; Einstadter, Douglas

    2017-09-01

    Patient portals have shown potential for increasing health care quality and efficiency. Internet access and other factors influencing patient portal use could worsen health disparities. Observational study of adults with 1 or more visits to the outpatient clinics of an urban public health care system from 2012 to 2015. We used mixed effects logistic regression to evaluate the association between broadband internet access and (1) patient portal initiation (whether a patient logged in at least 1 time) and (2) messaging, controlling for demographic and neighborhood characteristics. There were 243 248 adults with 1 or more visits during 2012-2015 and 70 835 (29.1%) initiated portal use. Portal initiation was 34.1% for whites, 23.4% for blacks, and 23.8% for Hispanics, and was lower for Medicaid (26.5%), Medicare (23.4%), and uninsured patients (17.4%) than commercially insured patients (39.3%). In multivariate analysis, both initiation of portal use (odds ratio [OR] = 1.24 per quintile, 95% confidence interval [CI], 1.23-1.24, P  internet access. The majority of adults with outpatient visits to a large urban health care system did not use the patient portal, and initiation of use was lower for racial and ethnic minorities, persons of lower socioeconomic status, and those without neighborhood broadband internet access. These results suggest the emergence of a digital divide in patient portal use. Given the scale of investment in patient portals and other internet-dependent health information technologies, efforts are urgently needed to address this growing inequality. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Portal hemodynamics in chronic portal-systemic encephalopathy

    International Nuclear Information System (INIS)

    Takashi, Motohide; Igarashi, Masahiko; Hino, Shinichi; Takayasu, Kenichi; Goto, Nobuaki; Musha, Hirotaka; Ohnishi, Kunihiko; Okuda, Kunio

    1985-01-01

    A portal hemodynamic study was made in 7 consecutive patients with chronic portal-systemic encephalopathy by percutaneous transhepatic catheterization of the portal vein and injecting contrast medium into the superior mesenteric vein or by superior mesenteric arterial portography in comparison with patients without encephalopathy studied by percutaneous catheterization of these veins. It is suggested that chronic portal-systemic encephalopathy is a result of a large collateral route shunting a large proportion of the superior mesenteric venous blood into systemic circulation, and that development of such collaterals precludes formation of large esophageal varices. (Auth.)

  8. On ANENT WEB portal: A quick view from Hanoi

    International Nuclear Information System (INIS)

    Phung Van Duan

    2005-01-01

    To set up a WEB-portal is one of the contents of an important activity of the Asian Network for Education in Nuclear Technology (ANENT). The web portal is directly connected with the other activities of ANENT. The first version of the web portal was prepared in time. It reflects the activities of ANENT as well as the important events and activities of IAEA. The NET DB can already serve as an official source for starting and developing many ANENT activities. Nevertheless, the compilation would be more valuable if it is enriched with additional information on material for Nuclear Technology Education, on activities of the ANENT member-institutions in field of Nuclear Education and so on. It would be desirable to intensify linkage for the purpose of effective exploration of the available information of the ANENT member-institutions as well as exploration of the other related web sites such as the one of ENEN and so on. To upgrade the web-portal and to diversify it might be one of the essential tasks for development of the web-portal. Developing the web-portal might simultaneously mean equipping it with the reference curricula and appropriate contents of the necessary courses for all forms of learning in nuclear fields which are commonly acceptable in ANENT. So, for development of the web-portal for ANENT, it would be also necessary to accelerate implementation of the other ANENT Activities, especially Activity 4 establishment of reference curricula and facilitating credit transfer and mutual recognition of degrees

  9. Nuclear Instrumentation Module (NIM) standard logic processor as a portal signal analyzer

    International Nuclear Information System (INIS)

    Minges, G.P.

    1978-01-01

    A general purpose electronic logic processor has been designed into a 2 wide NIM (Nuclear Instrumentation Module) bin module. The unit utilizes a microprocessor to achieve necessary versatility. The processor's first use is as a new generation signal analyzer for use in radiometric personnel and vehicle portal monitors. Significant improvements have been obtained in sensitivity and stability over existing analog discriminators. The new analyzer is presently being used to update personnel and vehicle portal monitoring systems

  10. Obliterative portal venopathy without portal hypertension: an underestimated condition.

    Science.gov (United States)

    Guido, Maria; Sarcognato, Samantha; Sonzogni, Aurelio; Lucà, Maria Grazia; Senzolo, Marco; Fagiuoli, Stefano; Ferrarese, Alberto; Pizzi, Marco; Giacomelli, Luciano; Colloredo, Guido

    2016-03-01

    Obliterative portal venopathy without portal hypertension has been described by a single study in a limited number of patients, thus very little is known about this clinical condition. This study aimed to investigate the prevalence of obliterative portal venopathy and its clinical-pathological correlations in patients with cryptogenic chronic liver test abnormalities without clinical signs of portal hypertension. We analysed 482 liver biopsies from adults with non-cirrhotic cryptogenic chronic liver disorders and without any clinical signs of portal hypertension, consecutively enrolled in a 5-year period. Twenty cases of idiopathic non-cirrhotic portal hypertension diagnosed in the same period, were included for comparison. Histological findings were matched with clinical and laboratory features. Obliterative portal venopathy was identified in 94 (19.5%) of 482 subjects and in all 20 cases of idiopathic non-cirrhotic portal hypertension: both groups shared the entire spectrum of histological changes described in the latter condition. The prevalence of incomplete fibrous septa and nodular regenerative hyperplasia was higher in the biopsies of idiopathic non-cirrhotic portal hypertension (P = 0.006 and P = 0.002), a possible hint of a more advanced stage of the disease. The two groups also shared several clinical laboratory features, including a similar liver function test profile, concomitant prothrombotic conditions and extrahepatic autoimmune disorders. Obliterative portal venopathy occurs in a substantial proportion of patients with unexplained chronic abnormal liver function tests without portal hypertension. The clinical-pathological profile of these subjects suggests that they may be in an early (non-symptomatic) stage of idiopathic non-cirrhotic portal hypertension. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. [Evaluation and treatment of portal hypertension].

    Science.gov (United States)

    Brůha, Radan; Petrtýl, Jaromír

    Liver cirrhosis is a serious disease shortening the life expectancy. Unavoidable consequence of cirrhosis is portal hypertension, which usually limits the prognosis by its complications. Portal hypertension is a prognostic factor for cirrhosis decompensation, variceal bleeding and even the mortality in cirrhotic patients. In the evaluation of portal hypertension hepatic venous pressure gradient (HVPG) measurement is used.Measurement of HVPG is used in clinical praxis in these situations: diagnosis of portal hypertension, evaluation of prognosis of patients with cirrhosis, monitoring the treatment efficacy in the prevention of variceal bleeding, management of acute variceal bleeding. Decrease of HVPG below 12 mmHg or at least for more than 20% of initial value in the treatment by beta-blockers is associated with the lower risk of bleeding from varices or other complications. HVPG above 20 mm Hg is associated with the high risk of early rebleeding from varices and can discriminate those patients profiting from early TIPS.HVPG measurement is an invasive, but simple, reproducible and safe catheterization technique with minimal complication rate. The most frequent complication could be incorrect assessment of obtained values. HVPG measurement should be a routine technique in centers specialized to liver diseases.

  12. Application of the smart portal in transportation

    International Nuclear Information System (INIS)

    Kercel, S.W.; Baylor, V.M.; Dress, W.B.; Hickerson, T.W.; Jatko, W.B.; Labaj, L.E.; Muhs, J.D.; Pack, R.M.

    1996-01-01

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developed a ''Portal-of-the-Future'', or ''smart portal''. This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiogram, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals

  13. Application of the smart portal in transportation

    Energy Technology Data Exchange (ETDEWEB)

    Kercel, S.W.; Baylor, V.M.; Dress, W.B.; Hickerson, T.W.; Jatko, W.B.; Labaj, L.E.; Muhs, J.D.; Pack, R.M.

    1996-12-31

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developed a ``Portal-of-the-Future``, or ``smart portal``. This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiogram, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals.

  14. Application of the smart portal in transportation

    Science.gov (United States)

    Kercel, Stephen W.; Baylor, Vivian M.; Dress, William B.; Hickerson, Tim W.; Jatko, William B.; Labaj, Leo E.; Muhs, Jeffrey D.; Pack, Richard M.

    1997-02-01

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developing a `Portal-of-the-Future', or `smart portal.' This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiograms, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals.

  15. Climate Outreach Using Regional Coastal Ocean Observing System Portals

    Science.gov (United States)

    Anderson, D. M.; Hernandez, D. L.; Wakely, A.; Bochenek, R. J.; Bickel, A.

    2015-12-01

    Coastal oceans are dynamic, changing environments affected by processes ranging from seconds to millennia. On the east and west coast of the U.S., regional observing systems have deployed and sustained a remarkable diverse array of observing tools and sensors. Data portals visualize and provide access to real-time sensor networks. Portals have emerged as an interactive tool for educators to help students explore and understand climate. Bringing data portals to outreach events, into classrooms, and onto tablets and smartphones enables educators to address topics and phenomena happening right now. For example at the 2015 Charleston Science Technology Engineering and Math (STEM) Festival, visitors navigated the SECOORA (Southeast Coastal Ocean Observing regional Association) data portal to view the real-time marine meteorological conditions off South Carolina. Map-based entry points provide an intuitive interface for most students, an array of time series and other visualizations depict many of the essential principles of climate science manifest in the coastal zone, and data down-load/ extract options provide access to the data and documentation for further inquiry by advanced users. Beyond the exposition of climate principles, the portal experience reveals remarkable technologies in action and shows how the observing system is enabled by the activity of many different partners.

  16. Designing the Search Service for Enterprise Portal based on Oracle Universal Content Management

    Science.gov (United States)

    Bauer, K. S.; Kuznetsov, D. Y.; Pominov, A. D.

    2017-01-01

    Enterprise Portal is an important part of an organization in informative and innovative space. The portal provides collaboration between employees and the organization. This article gives a valuable background of Enterprise Portal and technologies. The paper presents Oracle WebCenter Portal and UCM Server integration in detail. The focus is on tools for Enterprise Portal and on Search Service in particular. The paper also presents several UML diagrams to describe the use of cases for Search Service and main components of this application.

  17. Impact of hepatitis C oral therapy in portal hypertension.

    Science.gov (United States)

    Libânio, Diogo; Marinho, Rui Tato

    2017-07-14

    Chronic hepatitis C is a leading cause of morbidity and mortality, mainly related to fibrosis/cirrhosis and portal hypertension. Direct antiviral agents are highly effective and safe and can now cure > 90% of the patients. Sustained viral response (SVR) after interferon-based regimens has been associated with improvement in liver function, fibrosis and portal hypertension in a significant proportion of patients, although a point of no return seems to exist from which viral elimination is no longer capable of preventing portal hypertension progression and liver decompensation. Indeed, although SVR is associated with improvement of hepatic venous pressure gradients and therefore a decreased risk of de novo esophageal varices, several studies show that viral clearance does not eliminate the risk of variceal progression, liver decompensation and death in patients with pre-established portal hypertension. Although evidence about the effects of direct antiviral agents (DAAs) on clinically significant outcomes is still scarce and with short follow-up, DAAs can decrease the burden of the disease if patients are timely treated before significant fibrosis and portal hypertension develops. Studies with longer follow-up are waited to establish the real magnitude of hepatitis C treatment on portal hypertension. Future studies should also focus on predictors of portal hypertension resolution since it can influence management and avoid unnecessary monitoring.

  18. web portal usability among na case study of univer se study of ...

    African Journals Online (AJOL)

    User

    2014-04-02

    Apr 2, 2014 ... ABSTRACT. The web portal technology by Nigerian universitie university ... Portal Usability Success (WEBPUS) Model .... to deliver education to students [4]. Despite ..... and Mobile Research Lab (ITML) and group members.

  19. Radioisotopic flow scanning for portal blood flow and portal hypertension

    International Nuclear Information System (INIS)

    Hesdorffer, C.S.; Bezwoda, W.R.; Danilewitz, M.D.; Esser, J.D.; Tobias, M.

    1987-01-01

    The use of a simple, noninvasive, isotope scanning technique for the determination of relative portal blood flow and detection of portal hypertension is described. Using this technique the presence of portal hypertension was demonstrated in seven of nine patients known to have elevated portal venous pressure. By contrast, esophageal varices were demonstrated in only five of these patients, illustrating the potential value of the method. Furthermore, this technique has been adapted to the study of portal blood flow in patients with myeloproliferative disorders with splenomegaly but without disturbances in hepatic architecture. Results demonstrate that the high relative splenic flow resulting from the presence of splenomegaly may in turn be associated with elevated relative portal blood flow and portal hypertension. The theoretic reasons for the development of flow-related portal hypertension and its relationship to splenic blood flow are discussed

  20. CT portal venography manifestations of portal collateral circulation in patients with portal hypertension due to cirrhosis

    International Nuclear Information System (INIS)

    Ni Ming; Lv Weifu; Deng Kexue

    2009-01-01

    Objective: To analyze CT portal venography (CTPV) manifestations of portal collateral circulation in patients with cirrhosis by using a 16-detector row spiral CT scanner. Methods: CTPV was performed in 36 patients with portal hypertension due to cirrhosis, the diagnosis was proved by clinical data, hepatic function findings and imaging signs. By using post-processing reconstruction technique, 3D images of portal venous system and portal collateral circulation were obtained. Results: CTPV images displayed the portal venous system and its collateral circulation stereoscopically. Of 36 patients, left gastric varices were seen in 29(80.6%), lower esophageal varices in 18(50.0%), short gastric or posterior gastric varices in 15(41.7%), paraesophageal varices in 9(25.0%), gastro-renal or splenorenal shunts in 8(22.2%), spongelike transformation of portal vein in 7(19.4%), paraumbilical and abdominal wall varices in 6(16.7%), congenital cavernous in 6(16.7%) and paravertebral venous shunts in 4(11.1%). Conclusion: CTPV can well display the site, extent and severity of the portal collateral circulation in patients with portal hypertension due to cirrhosis,which is of great clinical importance for judging the patient's condition, for selecting therapeutic protocols and for estimating prognosis. (authors)

  1. Positive identity entry control system with geographically distributed portals and enrollment stations

    International Nuclear Information System (INIS)

    McIntire, J.M.

    1985-01-01

    A positive identity entry control system using distributed processing to allow reliable geographically separated portals and enrollment stations has been installed and is fully operational at a large area DOE site. Identity verification requires a credential, a memorized number and measurement of a physical characteristic of the user. Additionally, all portal activity is monitored by guards. The portal system is dual redundant such that no single point failure will shut down operations. Each portal site maintains its own subset of the master data base so off-site failure of the central data base manager or its communication links will not significantly affect local portal activity. The system is suitable for installations with large populations requiring access control at several remote sites scattered over a large area

  2. Portal Hypertension

    Science.gov (United States)

    ... Overview of Gallbladder Cancer Additional Content Medical News Portal Hypertension By Steven K. Herrine, MD, Professor of Medicine, ... Liver Hepatic Encephalopathy Jaundice in Adults Liver Failure Portal Hypertension Portal hypertension is abnormally high blood pressure in ...

  3. Optimising the neutron environment of Radiation Portal Monitors: A computational study

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Mark R., E-mail: mark.gilbert@ccfe.ac.uk [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Ghani, Zamir [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); McMillan, John E. [Department of Physics and Astronomy, University of Sheffield, Hicks building, Hounsfield Road, Sheffield S3 7RH (United Kingdom); Packer, Lee W. [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2015-09-21

    Efficient and reliable detection of radiological or nuclear threats is a crucial part of national and international efforts to prevent terrorist activities. Radiation Portal Monitors (RPMs), which are deployed worldwide, are intended to interdict smuggled fissile material by detecting emissions of neutrons and gamma rays. However, considering the range and variety of threat sources, vehicular and shielding scenarios, and that only a small signature is present, it is important that the design of the RPMs allows these signatures to be accurately differentiated from the environmental background. Using Monte-Carlo neutron-transport simulations of a model {sup 3}He detector system we have conducted a parameter study to identify the optimum combination of detector shielding, moderation, and collimation that maximises the sensitivity of neutron-sensitive RPMs. These structures, which could be simply and cost-effectively added to existing RPMs, can improve the detector response by more than a factor of two relative to an unmodified, bare design. Furthermore, optimisation of the air gap surrounding the helium tubes also improves detector efficiency.

  4. Portal hyperflow in patients with hepatosplenic mansonic schistosomiasis Hiperfluxo portal na forma hepatosplênica da esquistossomose mansônica

    Directory of Open Access Journals (Sweden)

    Roberto de Cleva

    2004-02-01

    Full Text Available PURPOSE: The purpose of this study was to assess portal hemodynamics in patients with portal hypertension due to hepatosplenic schistosomiasis as well as to assess the contribution of splanchnic hyperflow to the pathophysiology of the portal hypertension. METHODS: Sixteen patients with schistosomal portal hypertension and previous history of upper digestive bleeding due to esophageal varices rupture underwent elective esophagogastric devascularization and splenectomy and were prospectively studied. All patients underwent intraoperative invasive hemodynamic portal monitoring with a 4F-thermodilution catheter. The intraoperative portal hemodynamic assessment was conducted after laparotomy (initial and after esophagogastric devascularization (final. RESULTS: The initial portal pressure was elevated (mean 28.5 ± 4.5 mm Hg, and a significant drop of 25% was observed at the end of the surgery (21.9 ± 4.9 mm Hg. The initial portal flow was elevated (mean 1766.9 ± 686.6 mL/min. A significant fall (42% occurred at the end of the surgical procedure (1025.62 ± 338.7 mL/min. Fourteen patients (87.5% presented a portal flow of more than 1200 mL/min, and in 5 cases, values greater than 2000 mL/min were observed. CONCLUSIONS: Esophagogastric devascularization and splenectomy promote a significant reduction of the elevated portal pressure and flow in schistosomal portal hypertension. These data favor the hypothesis of portal hyperflow in the physiopathology of portal hypertension of schistosomiasis.OBJETIVOS: o objetivo do presente estudo é estudar a hemodinâmica portal em pacientes com hipertensão portal secundária a forma hepatoesplênica da esquistossomose e avaliar a contribuição do hiperfluxo esplênico na sua fisiopatologia CASUÍSTICA E MÉTODOS: Foram estudados prospectivamente 16 pacientes portadores de hipertensão portal secundária à forma hepatoesplênica da esquistossomose mansônica com indicação de tratamento cirúrgico. Todos foram

  5. A review of portal screen-film technology and five radiologists' evaluations of some existing products.

    Science.gov (United States)

    Walker, M A; Steinheimer, D N; Weir, V A; Homco, L D; Green, R W; Morris, E L; Hess, M E

    1999-01-01

    Portal radiographs, radiographs made to document the accuracy of radiotherapy treatment fields, are typically of poor image contrast. Recently, a new portal film and screened-cassette system was marketed, the Kodak EC-L system, with the claim of greatly improved image contrast. This new EC-L system was tested on a canine cadaver exposed to Cobalt-60 teletherapy gamma radiation, and image quality was compared to earlier marketed Kodak portal film products. The EC-L system was found to provide portal images of improved contrast/quality.

  6. Advanced Environmental Monitoring Technologies

    Science.gov (United States)

    Jan, Darrell

    2004-01-01

    Viewgraphs on Advanced Environmental Monitoring Technologies are presented. The topics include: 1) Monitoring & Controlling the Environment; 2) Illustrative Example: Canary 3) Ground-based Commercial Technology; 4) High Capability & Low Mass/Power + Autonomy = Key to Future SpaceFlight; 5) Current Practice: in Flight; 6) Current Practice: Post Flight; 7) Miniature Mass Spectrometer for Planetary Exploration and Long Duration Human Flight; 8) Hardware and Data Acquisition System; 9) 16S rDNA Phylogenetic Tree; and 10) Preview of Porter.

  7. Idiopathic portal hypertension

    International Nuclear Information System (INIS)

    Han, Tae Kyun; Ryu, Dae Sik; Kim, Heung Chul; Hur, Hun; Eom, Kyeung Tae; Namkung, Sook; Park, Man Soo; Hwang, Woo Chul; Lee, Kwan Seop

    1996-01-01

    To describe the radiologic findings of idiopathic portal hypertension and to find the points of differentiation between idiopathic portal hypertension and liver cirrhosis. Four portograms in five patients who for four years had suffered from pathologically confirmed idiopathic portal hypertension were retrospectively analyzed and compared with a portogram obtained from a control subject with liver cirrhosis. Portographic finding s of idiopathic portal hypertension were paucity of medium-sized portal branches, irregular and obtuse-angled division of peripheral branches, abrupt interruption and an avascular area beneath the liver margin. A portogram of idiopathic portal hypertension may be useful in differentiation this and liver cirrhosis

  8. Web-based service portal for decentral power supply systems. Remote monitoring and support of billing; Webbasiertes Service-Portal fuer dezentrale Energieanlagen. Fernueberwachung und Abrechnungsunterstuetzung

    Energy Technology Data Exchange (ETDEWEB)

    Silberg, Peter [EUS GmbH, Holzwickede (Germany); Bernemann, Andrew [MVV Energiedienstleistungen GmbH West, Solingen (Germany); Hillmann, Georg [Tema AG, Berlin (Germany)

    2010-01-15

    Web-based teleservice portals are a good basis for operating data acquisition and control of decentral power generation systems. They also provide a low-cost solution if open-source products are used. The authors present the teleservice portal of MVV Energiedinstleistungen GmbH that was developed by EUS GmbH. (orig.)

  9. Wireless fetal heart rate monitoring in inpatient full-term pregnant women: testing functionality and acceptability.

    Science.gov (United States)

    Boatin, Adeline A; Wylie, Blair; Goldfarb, Ilona; Azevedo, Robin; Pittel, Elena; Ng, Courtney; Haberer, Jessica

    2015-01-01

    We tested functionality and acceptability of a wireless fetal monitoring prototype technology in pregnant women in an inpatient labor unit in the United States. Women with full-term singleton pregnancies and no evidence of active labor were asked to wear the prototype technology for 30 minutes. We assessed functionality by evaluating the ability to successfully monitor the fetal heartbeat for 30 minutes, transmit this data to Cloud storage and view the data on a web portal. Three obstetricians also rated fetal cardiotocographs on ease of readability. We assessed acceptability by administering closed and open-ended questions on perceived utility and likeability to pregnant women and clinicians interacting with the prototype technology. Thirty-two women were enrolled, 28 of whom (87.5%) successfully completed 30 minutes of fetal monitoring including transmission of cardiotocographs to the web portal. Four sessions though completed, were not successfully uploaded to the Cloud storage. Six non-study clinicians interacted with the prototype technology. The primary technical problem observed was a delay in data transmission between the prototype and the web portal, which ranged from 2 to 209 minutes. Delays were ascribed to Wi-Fi connectivity problems. Recorded cardiotocographs received a mean score of 4.2/5 (± 1.0) on ease of readability with an interclass correlation of 0.81(95%CI 0.45, 0.96). Both pregnant women and clinicians found the prototype technology likable (81.3% and 66.7% respectively), useful (96.9% and 66.7% respectively), and would either use it again or recommend its use to another pregnant woman (77.4% and 66.7% respectively). In this pilot study we found that this wireless fetal monitoring prototype technology has potential for use in a United States inpatient setting but would benefit from some technology changes. We found it to be acceptable to both pregnant women and clinicians. Further research is needed to assess feasibility of using this

  10. Wireless fetal heart rate monitoring in inpatient full-term pregnant women: testing functionality and acceptability.

    Directory of Open Access Journals (Sweden)

    Adeline A Boatin

    Full Text Available We tested functionality and acceptability of a wireless fetal monitoring prototype technology in pregnant women in an inpatient labor unit in the United States. Women with full-term singleton pregnancies and no evidence of active labor were asked to wear the prototype technology for 30 minutes. We assessed functionality by evaluating the ability to successfully monitor the fetal heartbeat for 30 minutes, transmit this data to Cloud storage and view the data on a web portal. Three obstetricians also rated fetal cardiotocographs on ease of readability. We assessed acceptability by administering closed and open-ended questions on perceived utility and likeability to pregnant women and clinicians interacting with the prototype technology. Thirty-two women were enrolled, 28 of whom (87.5% successfully completed 30 minutes of fetal monitoring including transmission of cardiotocographs to the web portal. Four sessions though completed, were not successfully uploaded to the Cloud storage. Six non-study clinicians interacted with the prototype technology. The primary technical problem observed was a delay in data transmission between the prototype and the web portal, which ranged from 2 to 209 minutes. Delays were ascribed to Wi-Fi connectivity problems. Recorded cardiotocographs received a mean score of 4.2/5 (± 1.0 on ease of readability with an interclass correlation of 0.81(95%CI 0.45, 0.96. Both pregnant women and clinicians found the prototype technology likable (81.3% and 66.7% respectively, useful (96.9% and 66.7% respectively, and would either use it again or recommend its use to another pregnant woman (77.4% and 66.7% respectively. In this pilot study we found that this wireless fetal monitoring prototype technology has potential for use in a United States inpatient setting but would benefit from some technology changes. We found it to be acceptable to both pregnant women and clinicians. Further research is needed to assess feasibility of

  11. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  12. NUCLEONICA: a nuclear science portal

    International Nuclear Information System (INIS)

    Magill, J.; Galy, J.; Dreher, R.; Hamilton, D.; Tufan, M.; Normand, C.; Schwenk-Ferrero, A.; Wiese, H.W.

    2008-01-01

    NUCLEONICA is a new nuclear science web portal from the European Commission's Joint Research Centre. The portal provides a customizable, integrated environment and collaboration platform for the nuclear sciences using the latest 'Web 2.0' dynamic technology. NUCLEONICA is aimed at professionals, academics and students working with radionuclides in fields as diverse as the life sciences (e.g., biology, medicine, agriculture), the earth sciences (geology, meteorology, environmental science) and the more traditional disciplines such as nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. It is also used as a knowledge management tool to preserve nuclear knowledge built up over many decades by creating modern web-based versions of so-called legacy computer codes. (authors)

  13. An Approach for harmonizing European Water Portals

    Science.gov (United States)

    Pesquer, Lluís; Stasch, Christoph; Masó, Joan; Jirka, Simon; Domingo, Xavier; Guitart, Francesc; Turner, Thomas; Hinderk Jürrens, Eike

    2017-04-01

    A number of European funded research projects is developing novel solutions for water monitoring, modeling and management. To generate innovations in the water sector, third parties from industry and the public sector need to take up the solutions and bring them into the market. A variety of portals exists to support this move into the market. Examples on the European level are the EIP Water Online Marketplace(1), the WaterInnEU Marketplace(2), the WISE RTD Water knowledge portal(3), the WIDEST- ICT for Water Observatory(4) or the SWITCH-ON Virtual Product Market and Virtual Water-Science Laboratory(5). Further innovation portals and initiatives exist on the national or regional level, for example, the Denmark knows water platform6 or the Dutch water alliance(7). However, the different portals often cover the same projects, the same products and the same services. Since they are technically separated and have their own data models and databases, people need to duplicate information and maintain it at several endpoints. This requires additional efforts and hinders the interoperable exchange between these portals and tools using the underlying data. In this work, we provide an overview on the existing portals and present an approach for harmonizing and integrating common information that is provided across different portals. The approach aims to integrate the common in formation in a common database utilizing existing vocabularies, where possible. An Application Programming Interface allows access the information in a machine-readable way and utilizing the information in other applications beyond description and discovery purposes. (1) http://www.eip-water.eu/my-market-place (2) https://marketplace.waterinneu.org (3) http://www.wise-rtd.info/ (4) http://iwo.widest.eu (5) http://www.switch-on-vwsl.eu/ (6) http://www.rethinkwater.dk/ (7) http://wateralliance.nl/

  14. Offsite emergency radiological monitoring system and technology

    International Nuclear Information System (INIS)

    Mao Yongze

    1994-01-01

    The study and advance of the offsite radiological monitoring system and technology which is an important branch in the field of nuclear monitoring technology are described. The author suggests that the predicting and measuring system should be involved in the monitoring system. The measuring system can further be divided into four sub-systems, namely plume exposure pathway, emergency worker, ingestion exposure pathway and post accident recovery measuring sub-systems. The main facilities for the monitoring system are concluded as one station, one helicopter, one laboratory and two vehicles. The instrumentation for complement of the facilities and their good performance characteristics, up-to-date technology are also introduced in brief. The offsite emergency radiation monitoring system and technology are compared in detail with those recommended by FEMA U.S.A.. Finally the paper discusses some trends in development of emergency radiation monitoring system and technology in the developed countries

  15. Outcomes of pregnancies complicated by liver cirrhosis, portal hypertension, or esophageal varices.

    Science.gov (United States)

    Puljic, Anela; Salati, Jennifer; Doss, Amy; Caughey, Aaron B

    2016-01-01

    To evaluate pregnancy outcomes in women with liver cirrhosis, portal hypertension, or esophageal varices. We analyzed a retrospective cohort of 2,284,218 pregnancies in 2005-2009 recorded in the California Birth Registry database. Utilizing ICD-9 codes we analyzed the following outcomes for liver cirrhosis, portal hypertension, or esophageal varices in pregnancy: preeclampsia (PET), preterm delivery (PTD; Portal hypertension in pregnancy was associated with PTD, LBW, NND, and PPH. Non-bleeding esophageal varices in pregnancy were not associated with the outcomes assessed in a statistically significant manner. One case of bleeding esophageal varices was observed, resulting in PTD with a LBW infant. There were three cases of concomitant portal hypertension or concomitant esophageal varices with cirrhosis in pregnancy. Pregnancy in women with concomitant liver cirrhosis, portal hypertension, or esophageal varices can be successful. However, pregnancy outcomes are worse and may warrant closer antenatal monitoring and patient counseling. Cirrhosis in pregnancy with concomitant portal hypertension or esophageal varices is rare.

  16. Federal High End Computing (HEC) Information Portal

    Data.gov (United States)

    Networking and Information Technology Research and Development, Executive Office of the President — This portal provides information about opportunities to engage in U.S. Federal government high performance computing activities, including supercomputer use,...

  17. 29 CFR 785.24 - Principles noted in Portal-to-Portal Bulletin.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Principles noted in Portal-to-Portal Bulletin. 785.24 Section 785.24 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR... of Principles Preparatory and Concluding Activities § 785.24 Principles noted in Portal-to-Portal...

  18. Asian Network for Education in Nuclear Technology (ANENT). Report of the IAEA regional workshop on the development of a web-portal for ANENT

    International Nuclear Information System (INIS)

    2007-01-01

    The report contains the status of the development of anent web-portal, the country evaluation of the web-portal, the summary evaluation and suggested preparation of an operation system for anent web-portal, suggestions on upgrading of anent web-portal (including the systematic connection to other web portals, the improvement on the content, E/Cyber learning, display of the periodic review, user groups and mailing list). The workshop participants have concluded that, in general, the ANENT web-portal developed by GA (Group Activity) 1 coordinator is considered as appropriate and user friendly as the infrastructure for promoting, managing and preserving nuclear knowledge and facilitating the ANENT Group Activities. ANENT is one of the mechanisms to enhance Technical Cooperation amongst Developing Countries and an initiative for Knowledge Management Practice in the region. The developed ANENT Web portal is an important platform to facilitate the fellowship-training placement of fellows not only under the IAEA Technical Cooperation Fellowship and Training Program but also for other regional and national programs in nuclear science and technology. For revising the web-portal in the short term, a number of comments were provided by the participants. Some of them were already implemented in the current version of web-portal during the workshop. The operation management system was prepared, which will be exercised until it is submitted to the 2nd Coordination Committee Meeting for approval and further possible changes. The prepared system covers mode of operation, operation management activities, responsibilities and operation management process: KAERI will designate a web-portal system administrator and each member country will nominate a data provider. For security, a back up system will be established. An alternative access control system was suggested for consideration in the 2nd Coordination Committee meeting in order to attract the general users providing them more

  19. Monitoring of structures: review of technologies

    International Nuclear Information System (INIS)

    2013-01-01

    Structural Health Monitoring (SHM) aims at monitoring the integrity of structures either in a continuous way or periodically. SHM is used for the monitoring of big civil works like bridges, dams, railways or critical structures like nuclear power plants or chemical plants. The sensors fixed on the structure allow an in-service monitoring. SHM gathers various technologies like ultrasound, acoustic emission, vibrations, Foucault currents...A technology based on guided ultrasonic waves (Lamb waves) appears promising for monitoring large structures made of composite materials. Another technology based on optical fibers can be used in very harsh environment and the optic fiber does not require any more sensors, the optical fiber itself being the sensor. The optical fiber is generally integrated to the structure during the construction phase. (A.C.)

  20. Rain-Induced Increase in Background Radiation Detected by Radiation Portal Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Hausladen, Paul [ORNL; Blessinger, Christopher S [ORNL; Guzzardo, Tyler [ORNL; Livesay, Jake [ORNL

    2012-07-01

    A complete understanding of both the steady state and transient background measured by Radiation Portal Monitors (RPMs) is essential to predictable system performance, as well as maximization of detection sensitivity. To facilitate this understanding, a test bed for the study of natural background in RPMs has been established at the Oak Ridge National Laboratory. This work was performed in support of the Second Line of Defense Program's mission to detect the illicit movement of nuclear material. In the present work, transient increases in gamma ray counting rates in RPMs due to rain are investigated. The increase in background activity associated with rain, which has been well documented in the field of environmental radioactivity, originates from the atmospheric deposition of two radioactive daughters of radon-222, namely lead-214 and bismuth-214 (henceforth {sup 222}Rn, {sup 214}Pb and {sup 214}Bi). In this study, rainfall rates recorded by a co-located weather station are compared with RPM count rates and High Purity Germanium spectra. The data verifies these radionuclides are responsible for the dominant transient natural background fluctuations in RPMs. Effects on system performance and potential mitigation strategies are discussed.

  1. Splenic embolization in cirrhotic patients with portal hypertension

    International Nuclear Information System (INIS)

    Falappa, P.G.; Cotroneo, A.R.; De Cinque, M.; Maresca, G.; Patane', D.

    1988-01-01

    Over the last four years the authors performed transcatheter embolization of the splenic artery by Gianturco coils in 32 consecutive cirrhotic patients with portal hypertension, splenomegaly, cytopenia and gastro-esophageal varices endoscopically proved. This procedure was especially useful for treatement of splenomegaly and cytopenia because a constant reduction of spleen dimensions and increase in platelet count were registered. The effectiveness of transcatheter embolization and follow-up are based on clinic, hematologic and sonographic findings. Sonographic monitoring is believed to be very useful both to evaluate splenomegaly and signs of portal hypertension and to reveal splenic complications (abscesses). Severe complications have been never registered

  2. Portal hypertensiv gastropati

    DEFF Research Database (Denmark)

    Brinch, K; Møller, S; Henriksen, Jens Henrik Sahl

    1995-01-01

    Portal hypertensive gastropathy (PHG) as defined by congestive changes in the gastric mucosa owing to increased portal pressure, was first described about ten years ago. Whereas definition and grading of severity are still under debate, there is general agreement that PHG is a new clinical entity....... PHG is present in 50-80% of patients with liver cirrhosis. PHG is a major cause of upper gastrointestinal bleeding in patients with portal hypertension (25-90% depending on severity). Presence of portal hypertension is a prerequisite for the development of PHG, and reduction of portal pressure...

  3. New technologies for item monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, J.A. [EG & G Energy Measurements, Albuquerque, NM (United States); Waddoups, I.G. [Sandia National Labs., Albuquerque, NM (United States)

    1993-12-01

    This report responds to the Department of Energy`s request that Sandia National Laboratories compare existing technologies against several advanced technologies as they apply to DOE needs to monitor the movement of material, weapons, or personnel for safety and security programs. The authors describe several material control systems, discuss their technologies, suggest possible applications, discuss assets and limitations, and project costs for each system. The following systems are described: WATCH system (Wireless Alarm Transmission of Container Handling); Tag system (an electrostatic proximity sensor); PANTRAK system (Personnel And Material Tracking); VRIS (Vault Remote Inventory System); VSIS (Vault Safety and Inventory System); AIMS (Authenticated Item Monitoring System); EIVS (Experimental Inventory Verification System); Metrox system (canister monitoring system); TCATS (Target Cueing And Tracking System); LGVSS (Light Grid Vault Surveillance System); CSS (Container Safeguards System); SAMMS (Security Alarm and Material Monitoring System); FOIDS (Fiber Optic Intelligence & Detection System); GRADS (Graded Radiation Detection System); and PINPAL (Physical Inventory Pallet).

  4. New technologies for item monitoring

    International Nuclear Information System (INIS)

    Abbott, J.A.; Waddoups, I.G.

    1993-12-01

    This report responds to the Department of Energy's request that Sandia National Laboratories compare existing technologies against several advanced technologies as they apply to DOE needs to monitor the movement of material, weapons, or personnel for safety and security programs. The authors describe several material control systems, discuss their technologies, suggest possible applications, discuss assets and limitations, and project costs for each system. The following systems are described: WATCH system (Wireless Alarm Transmission of Container Handling); Tag system (an electrostatic proximity sensor); PANTRAK system (Personnel And Material Tracking); VRIS (Vault Remote Inventory System); VSIS (Vault Safety and Inventory System); AIMS (Authenticated Item Monitoring System); EIVS (Experimental Inventory Verification System); Metrox system (canister monitoring system); TCATS (Target Cueing And Tracking System); LGVSS (Light Grid Vault Surveillance System); CSS (Container Safeguards System); SAMMS (Security Alarm and Material Monitoring System); FOIDS (Fiber Optic Intelligence ampersand Detection System); GRADS (Graded Radiation Detection System); and PINPAL (Physical Inventory Pallet)

  5. An Invitation to Collaborate: The SPIRIT Open Source Health Care Portal

    Science.gov (United States)

    Bray, Brian; Molin, Joseph Dal

    2001-01-01

    The SPIRIT portal is a web site resulting from a joint project of the European Commission 5th Framework Research Programme for Information Society Technologies, Minoru Development (France), Conecta srl (Italy), and Sistema Information Systems (Italy). The portal indexes and disseminates free software, serves as a meeting point for health care informatics researchers, and provides collaboration services to health care innovators. This poster session describes the services of the portal and invites researchers to join a worldwide collaborative community developing evidence based health care solutions.

  6. Calculation of neutron die-away times in a large-vehicle portal monitor

    International Nuclear Information System (INIS)

    Lillie, R.A.; Santoro, R.T.; Alsmiller, R.G. Jr.

    1980-05-01

    Monte Carlo methods have been used to calculate neutron die-away times in a large-vehicle portal monitor. These calculations were performed to investigate the adequacy of using neutron die-away time measurements to detect the clandestine movement of shielded nuclear materials. The geometry consisted of a large tunnel lined with He 3 proportional counters. The time behavior of the (n,p) capture reaction in these counters was calculated when the tunnel contained a number of different tractor-trailer load configurations. Neutron die-away times obtained from weighted least squares fits to these data were compared. The change in neutron die-away time due to the replacement of cargo in a fully loaded truck with a spherical shell containing 240 kg of borated polyethylene was calculated to be less than 3%. This result together with the overall behavior of neutron die-away time versus mass inside the tunnel strongly suggested that measurements of this type will not provide a reliable means of detecting shielded nuclear materials in a large vehicle. 5 figures, 4 tables

  7. Comparison of PVT and NaI(Tl) scintillators for vehicle portal monitor applications

    International Nuclear Information System (INIS)

    Siciliano, E.R.; Ely, J.H.; Kouzes, R.T.; Milbrath, B.D.; Schweppe, J.E.; Stromswold, D.C.

    2005-01-01

    The demand for radiation portal monitor (RPM) systems has increased, and their capabilities are being further scrutinized as they are being applied to the task of detecting nuclear weapons, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, where RPMs have been historically employed. In this new homeland security application, RPM systems must rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce. In light of this new Department of Homeland Security application, the capabilities of two popular gamma-ray-detector materials as applied to these needs are re-examined. Both experimental data and computer simulations, together with practical deployment experience, are used to assess currently available polyvinyltoluene and NaI(Tl) gamma-ray detectors for border applications

  8. Rare Disease Video Portal

    OpenAIRE

    Sánchez Bocanegra, Carlos Luis

    2011-01-01

    Rare Disease Video Portal (RD Video) is a portal web where contains videos from Youtube including all details from 12 channels of Youtube. Rare Disease Video Portal (RD Video) es un portal web que contiene los vídeos de Youtube incluyendo todos los detalles de 12 canales de Youtube. Rare Disease Video Portal (RD Video) és un portal web que conté els vídeos de Youtube i que inclou tots els detalls de 12 Canals de Youtube.

  9. A new rat model of portal hypertension induced by intraportal injection of microspheres

    Science.gov (United States)

    Li, Xiang-Nong; Benjamin, IS; Alexander, B

    1998-01-01

    AIM: To produce a new rat model of portal hypertension by intraportal injection of microspheres. METHODS: Measured aliquots of single or different-sized microspheres (15, 40, 80μm) were injected into the portal vein to block intrahepatic portal radicals. The resultant changes in arterial,portal,hepatic venous and splenic pulp pressures were monitored. The liver and lungs were excised for histological examination. RESULTS: Portal venous pressure was elevated from basal value of 0.89-1.02 kPa to a steady-state of 1.98-3.19 kPa following the sequential injections of single- or different-sized microspheres, with a markedly lowered mean arterial pressure. However, a small-dose injection of 80 μm microspheres (1.8 × 105) produced a steady-state portal venous pressure of 2.53 × 0.17 kPa, and all rats showed normal arterial pressures. In addition, numerous microspheres were found in the lungs in all experimental groups. CONCLUSION: Portal hypertension can be reproduced in rats by intraportal injection of microspheres at a small dose of 80 μm (1.8 × 105). Intrahepatic portal-systemic shunts probably exist in the normal rat liver. PMID:11819236

  10. Environmental and process monitoring technologies

    International Nuclear Information System (INIS)

    Vo-Dinh, Tuan

    1993-01-01

    The objective of this conference was to provide a multidisciplinary forum dealing with state-of-the-art methods and instrumentation for environmental and process monitoring. In the last few years, important advances have been made in improving existing analytical methods and developing new techniques for trace detection of chemicals. These monitoring technologies are a topic of great interest for environmental and industrial control in a wide spectrum of areas. Sensitive detection, selective characterization, and cost-effective analysis are among the most important challenges facing monitoring technologies. This conference integrating interdisciplinary research and development was aimed to present the most recent advances and applications in the important areas of environmental and process monitoring. Separate abstracts have been prepared for 34 papers for inclusion in the appropriate data bases

  11. Characterization monitoring & sensor technology crosscutting program

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    The purpose of the Characterization, Monitoring, and Sensor Technology Crosscutting Program (CMST-CP) is to deliver appropriate characterization, monitoring, and sensor technology (CMST) to the OFfice of Waste Management (EM-30), the Office of Environmental Restoration (EM-40), and the Office of Facility Transition and Management (EM-60).

  12. Treatment of portal hypertension caused by benign main portal vein stenosis with endovascular stent

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Guan Shouhai; Zhu Kangshun; Li Zhengran; Zhou Yubin; He Bingjun

    2004-01-01

    Objective: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Methods: Portal vein stents were implanted in 6 patients with benign main portal vein stenosis (inflammatory stenosis in 3 cases, postprocedure of liver transplantation in another 3 cases). The change of portal vein pressure, the patency of portal vein, relative clinical symptoms, complications, and survival were evaluated. Results: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in all 6 patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3 ± 4.7) cm H 2 O (1 cm H 2 O=0.098 kPa) to (18.0 ± 1.9) cm H 2 O (P<0.001). The portal blood flow was restored, and the symptoms caused by portal hypertension were eliminated. There was no severe procedure-related complication. Follow-up time was from 5 to 36 months. The portal vein remained patent during the follow-up. All patients survived except one patient who died of other complications of liver transplantation. Conclusion: Percutaneous portal vein stent placement for the treatment of the benign main portal vein stenosis is safe and effective. (authors)

  13. Noncirrhotic portal hypertension.

    Science.gov (United States)

    Da, Ben L; Koh, Christopher; Heller, Theo

    2018-05-01

    Noncirrhotic portal hypertension represents a heterogeneous group of liver disorders that is characterized by portal hypertension in the absence of cirrhosis. The purpose of this review is to serve as a guide on how to approach a patient with noncirrhotic portal hypertension with a focus on recent developments. Recent studies pertaining to noncirrhotic portal hypertension have investigated aetiological causes, mechanisms of disease, noninvasive diagnostic modalities, clinical characteristics in the paediatric population and novel treatment targets. Noncirrhotic portal hypertension is an underappreciated clinical entity that can be difficult to diagnosis without a healthy suspicion. Diagnosis then relies on a comprehensive understanding of the causes and clinical manifestations of this disease, as well as a careful interpretation of the liver biopsy. Noninvasive approaches to diagnosis may play a significant role moving forward in this disease. Treatment in NCPH remains largely targeted at the individual sequalae of portal hypertension.

  14. The secondary metabolite bioinformatics portal

    DEFF Research Database (Denmark)

    Weber, Tilmann; Kim, Hyun Uk

    2016-01-01

    . In this context, this review gives a summary of tools and databases that currently are available to mine, identify and characterize natural product biosynthesis pathways and their producers based on ‘omics data. A web portal called Secondary Metabolite Bioinformatics Portal (SMBP at http...... analytical and chemical methods gave access to this group of compounds, nowadays genomics-based methods offer complementary approaches to find, identify and characterize such molecules. This paradigm shift also resulted in a high demand for computational tools to assist researchers in their daily work......Natural products are among the most important sources of lead molecules for drug discovery. With the development of affordable whole-genome sequencing technologies and other ‘omics tools, the field of natural products research is currently undergoing a shift in paradigms. While, for decades, mainly...

  15. Stakeholder Expectations of Service Quality in a University Web Portal

    Science.gov (United States)

    Tate, Mary; Evermann, Joerg; Hope, Beverley; Barnes, Stuart

    Online service quality is a much-studied concept. There is considerable evidence that user expectations and perceptions of self-service and online service quality differ in different business domains. In addition, the nature of online services is continually changing and universities have been at the forefront of this change, with university websites increasingly acting as a portal for a wide range of online transactions for a wide range of stakeholders. In this qualitative study, we conduct focus groups with a range of stakeholders in a university web portal. Our study offers a number of insights into the changing nature of the relationship between organisations and customers. New technologies are influencing customer expectations. Customers increasingly expect organisations to have integrated information systems, and to utilise new technologies such as SMS and web portals. Organisations can be slow to adopt a customer-centric viewpoint, and persist in providing interfaces that are inconsistent or require inside knowledge of organisational structures and processes. This has a negative effect on customer perceptions.

  16. Portal information website construction and practice of Southwestern Institute of Physics

    International Nuclear Information System (INIS)

    Zhang Yiming; Zeng Liping

    2010-01-01

    The portal website of an organization, which directly reflects its image, is an important platform for providing the public with information service and publicizing the corporate philosophy and culture. For a scientific research institute, the portal website plays an active role in publicizing and popularizing scientific and technological knowledge as well as the above roles. Good development and management of the portal website will help to display the good image of a corporation, promote its exchanges with other countries and enhance the smooth running of each work. This paper introduces the preliminary attempt and practice of the Fusion Information Division, SWIP in building SWIP portal website and raising its vigor and vitality so as to promote common exchange and development. (authors)

  17. Bedload-surrogate monitoring technologies

    Science.gov (United States)

    Gray, John R.; Laronne, Jonathan B.; Marr, Jeffrey D.G.

    2010-01-01

    Advances in technologies for quantifying bedload fluxes and in some cases bedload size distributions in rivers show promise toward supplanting traditional physical samplers and sampling methods predicated on the collection and analysis of physical bedload samples. Four workshops held from 2002 to 2007 directly or peripherally addressed bedload-surrogate technologies, and results from these workshops have been compiled to evaluate the state-of-the-art in bedload monitoring. Papers from the 2007 workshop are published for the first time with this report. Selected research and publications since the 2007 workshop also are presented. Traditional samplers used for some or all of the last eight decades include box or basket samplers, pan or tray samplers, pressure-difference samplers, and trough or pit samplers. Although still useful, the future niche of these devices may be as a means for calibrating bedload-surrogate technologies operating with active- and passive-type sensors, in many cases continuously and automatically at a river site. Active sensors include acoustic Doppler current profilers (ADCPs), sonar, radar, and smart sensors. Passive sensors include geophones (pipes or plates) in direct contact with the streambed, hydrophones deployed in the water column, impact columns, and magnetic detection. The ADCP for sand and geophones for gravel are currently the most developed techniques, several of which have been calibrated under both laboratory and field conditions. Although none of the bedload-surrogate technologies described herein are broadly accepted for use in large-scale monitoring programs, several are under evaluation. The benefits of verifying and operationally deploying selected bedload-surrogate monitoring technologies could be considerable, providing for more frequent and consistent, less expensive, and arguably more accurate bedload data obtained with reduced personal risk for use in managing the world's sedimentary resources. Twenty-six papers are

  18. Editor's welcome, PORTAL, Vol. 2, No. 1, January 2005

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2005-03-01

    Full Text Available This special issue of PORTAL Journal of Multidisciplinary International Studies, jointly edited by Jo McCormack and Paul Allatson, is dedicated to exile and social transformation. Some of the papers presented here derive from a highly successful workshop and symposium on exile held at the Institute for International Studies, University of Technology Sydney, in July and December 2004. Others arrived in response to a call for papers sent out in early 2004, which attracted a great deal of attention. We would like to thank all those involved at the first two events for their productive discussions and feedback, and extend our thanks to the many people who responded to the call for papers on the topic. The next issue of PORTAL will also be a special issue, “Strange Localities: Utopias, Intellectuals and National Identities in the 21st Century,” with three guest editors: Alistair Fox (University of Otago, Murray Pratt (University of Technology, Sydney, and Hilary Radner (University of Otago. And, as always, we would like to encourage practitioners of international studies and cultural producers working anywhere in the world, and in any of the PORTAL languages, to submit material for future issues. Finally, and returning to this issue’s special theme, it was with great sadness that we learned from one of the contributors to this issue, Sue Hajdú, of her father’s recent death. Sue’s critical and creative meditation on her father’s status as a Hungarian exile is one of this issue’s highlights. On behalf of the members of the Portal Editorial Committee, this special issue is dedicated to him. Paul Allatson, Chair, PORTAL Editorial Committee

  19. Portal vein thrombosis.

    Science.gov (United States)

    Chawla, Yogesh K; Bodh, Vijay

    2015-03-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion.

  20. Development of an e-learning portal for pediatric endocrinology: educational considerations.

    Science.gov (United States)

    Grijpink-van den Biggelaar, K; Drop, S L S; Schuwirth, L

    2010-01-01

    Global accessibility and dissemination of developments in pediatric endocrinology prompted to examine how to develop an educational interactive e-SPE web portal. A systematic approach was used to identify the relevant aspects of accessibility and dissemination. An orientation at the big idea was made, executed by an analysis of the needs of student and teacher pediatric endocrinologists, a definition of the learning objectives, a research in educational literature and an exploration of ICT design specifications. The intensive collaboration between medical, educational and information technology disciplines resulted in a portal design. The portal meets requirements of adult learning, stresses interaction between partners in learning and offers direct feedback during the learning process. The portal supports the development of not only knowledge but also competences both at junior and advanced levels. When the e-SPE portal is completed, the options for summative assessment will be examined as a medium for international certification in conjunction with local and national requirements (http://espe.elearning.nl). Copyright 2010 S. Karger AG, Basel.

  1. Macronodular hepatic tuberculosis associated with portal vein thrombosis and portal hypertension

    International Nuclear Information System (INIS)

    Venkatesh, S.K.; Tan, L.K.A.; Siew, E.P.Y.; Putti, T.C.

    2005-01-01

    Tuberculosis (TB) of the liver is usually associated with miliary spread. Macronodular TB of the liver is rare. A case of macronodular TB of the liver in a 31-year-old woman causing portal vein thrombosis and portal hypertension is presented. Ultrasound and CT appearances are described. There was coexistent ileo-caecal TB with extensive mesenteric and retroperitoneal lymphadenopathy. Macronodular TB should be considered in the differential diagnosis when a patient presents with multiple calcified masses in the liver with portal vein thrombosis and portal hypertension. Copyright (2005) Blackwell Science Pty Ltd

  2. LifeWatchGreece Portal development: architecture, implementation and challenges for a biodiversity research e-infrastructure.

    Science.gov (United States)

    Gougousis, Alexandros; Bailly, Nicolas

    2016-01-01

    Biodiversity data is characterized by its cross-disciplinary character, the extremely broad range of data types and structures, and the plethora of different data sources providing resources for the same piece of information in a heterogeneous way. Since the web inception two decades ago, there are multiple initiatives to connect, aggregate, share, and publish biodiversity data, and to establish data and work flows in order to analyze them. The European program LifeWatch aims at establishing a distributed network of nodes implementing virtual research environment in Europe to facilitate the work of biodiversity researchers and managers. LifeWatchGreece is one of these nodes where a portal was developed offering access to a suite of virtual laboratories and e-services. Despite its strict definition in information technology, in practice "portal" is a fairly broad term that embraces many web architectures. In the biodiversity domain, the term "portal" is usually used to indicate either a web site that provides access to a single or an aggregation of data repositories (like: http://indiabiodiversity.org/, http://www.mountainbiodiversity.org/, http://data.freshwaterbiodiversity.eu), a web site that gathers information about various online biodiversity tools (like http://test-eubon.ebd.csic.es/, http://marine.lifewatch.eu/) or a web site that just gathers information and news about the biodiversity domain (like http://chm.moew.government.bg). LifeWatchGreece's portal takes the concept of a portal a step further. In strict IT terms, LifeWatchGreece's portal is partly a portal, partly a platform and partly an aggregator. It includes a number of biodiversity-related web tools integrated into a centrally-controlled software ecosystem. This ecosystem includes subsystems for access control, traffic monitoring, user notifications and web tool management. These subsystems are shared to all the web tools that have been integrated to the portal and thereby are part of this

  3. The effect of patient portals on quality outcomes and its implications to meaningful use: a systematic review.

    Science.gov (United States)

    Kruse, Clemens Scott; Bolton, Katy; Freriks, Greg

    2015-02-10

    The Health Information Technology for Economic and Clinical Health (HITECH) Act imposes pressure on health care organizations to qualify for "Meaningful Use". It is assumed that portals should increase patient participation in medical decisions, but whether or not the use of portals improves outcomes remains to be seen. The purpose of this systemic review is to outline and summarize study results on the effect of patient portals on quality, or chronic-condition outcomes as defined by the Agency for Healthcare Research and Quality, and its implications to Meaningful Use since the beginning of 2011. This review updates and builds on the work by Ammenwerth, Schnell-Inderst, and Hoerbst. We performed a systematic literature search in PubMed, CINAHL, and Google Scholar. We identified any data-driven study, quantitative or qualitative, that examined a relationship between patient portals, or patient portal features, and outcomes. We also wanted to relate the findings back to Meaningful Use criteria. Over 4000 articles were screened, and 27 were analyzed and summarized for this systematic review. We identified 26 studies and 1 review, and we summarized their findings and applicability to our research question. Very few studies associated use of the patient portal, or its features, to improved outcomes; 37% (10/27) of papers reported improvements in medication adherence, disease awareness, self-management of disease, a decrease of office visits, an increase in preventative medicine, and an increase in extended office visits, at the patient's request for additional information. The results also show an increase in quality in terms of patient satisfaction and customer retention, but there are weak results on medical outcomes. The results of this review demonstrate that more health care organizations today offer features of a patient portal than in the review published in 2011. Articles reviewed rarely analyzed a full patient portal but instead analyzed features of a portal

  4. The Effect of Patient Portals on Quality Outcomes and Its Implications to Meaningful Use: A Systematic Review

    Science.gov (United States)

    2015-01-01

    Background The Health Information Technology for Economic and Clinical Health (HITECH) Act imposes pressure on health care organizations to qualify for “Meaningful Use”. It is assumed that portals should increase patient participation in medical decisions, but whether or not the use of portals improves outcomes remains to be seen. Objective The purpose of this systemic review is to outline and summarize study results on the effect of patient portals on quality, or chronic-condition outcomes as defined by the Agency for Healthcare Research and Quality, and its implications to Meaningful Use since the beginning of 2011. This review updates and builds on the work by Ammenwerth, Schnell-Inderst, and Hoerbst. Methods We performed a systematic literature search in PubMed, CINAHL, and Google Scholar. We identified any data-driven study, quantitative or qualitative, that examined a relationship between patient portals, or patient portal features, and outcomes. We also wanted to relate the findings back to Meaningful Use criteria. Over 4000 articles were screened, and 27 were analyzed and summarized for this systematic review. Results We identified 26 studies and 1 review, and we summarized their findings and applicability to our research question. Very few studies associated use of the patient portal, or its features, to improved outcomes; 37% (10/27) of papers reported improvements in medication adherence, disease awareness, self-management of disease, a decrease of office visits, an increase in preventative medicine, and an increase in extended office visits, at the patient’s request for additional information. The results also show an increase in quality in terms of patient satisfaction and customer retention, but there are weak results on medical outcomes. Conclusions The results of this review demonstrate that more health care organizations today offer features of a patient portal than in the review published in 2011. Articles reviewed rarely analyzed a full

  5. Noncirrotisk intrahepatisk portal hypertension

    DEFF Research Database (Denmark)

    Dam Fialla, Annette; Havelund, Troels

    2007-01-01

    Non-cirrhotic intrahepatic portal hypertension is characterized by portal hypertension in the absence of liver cirrhosis or portal vein thrombosis. The disease is common in the East and rarely seen in the West. Two cases with oesophageal varices are described. The histopathology is heterogeneous...... but includes vascular lesions and portal fibrosis. Patient management follows the current recommendations for variceal bleeding....

  6. Health Monitoring System Technology Assessments: Cost Benefits Analysis

    Science.gov (United States)

    Kent, Renee M.; Murphy, Dennis A.

    2000-01-01

    The subject of sensor-based structural health monitoring is very diverse and encompasses a wide range of activities including initiatives and innovations involving the development of advanced sensor, signal processing, data analysis, and actuation and control technologies. In addition, it embraces the consideration of the availability of low-cost, high-quality contributing technologies, computational utilities, and hardware and software resources that enable the operational realization of robust health monitoring technologies. This report presents a detailed analysis of the cost benefit and other logistics and operational considerations associated with the implementation and utilization of sensor-based technologies for use in aerospace structure health monitoring. The scope of this volume is to assess the economic impact, from an end-user perspective, implementation health monitoring technologies on three structures. It specifically focuses on evaluating the impact on maintaining and supporting these structures with and without health monitoring capability.

  7. Hepatic angiography: Portal hypertension

    International Nuclear Information System (INIS)

    Oliver, T.W. Jr.; Sones, P.J. Jr.

    1985-01-01

    Portal hypertension is usually a manifestation of underlying hepatic parenchymal disease, although it may be secondary to portal or hepatic venous thrombosis and rarely to hyperdynamic portal states. Portal hypertension may present as encephalopathy, ascites, jaundice, hepatic failure, or catastrophic upper gastrointestinal hemorrhage. Radiologic investigation should include indirect or direct measurements of portal pressure, assessment of portal venous perfusion, visualization of collaterals, and demonstration of arterial and venous anatomy for potential shunt procedure. Following survival of initial variceal bleeding, the most effective procedure to prevent recurrent hemorrhage is a shunt to decompress the varices. The decision whether to intervene medically or surgically during the acute hemorrhagic episode as well as the type of shunt used to prevent future hemorrhage is the subject of continuing controversy

  8. Characterization, monitoring, and sensor technology crosscutting program: Technology summary

    International Nuclear Information System (INIS)

    1995-06-01

    The purpose of the Characterization, Monitoring, and Sensor Technology Crosscutting Program (CMST-CP) is to deliver appropriate characterization, monitoring, and sensor technology (CMST) to the Office of Waste Management (EM-30), the Office of Environmental Restoration (EM-40), and the Office of Facility Transition and Management (EM-60). The technology development must also be cost effective and appropriate to EM-30/40/60 needs. Furthermore, the required technologies must be delivered and implemented when needed. Accordingly, and to ensure that available DOE and other national resources are focused an the most pressing needs, management of the technology development is concentrated on the following Focus Areas: Contaminant Plume Containment and Remediation (PFA); Landfill Stabilization (LSFA); High-Level Waste Tank Remediation (TFA); Mixed Waste Characterization, Treatment, and Disposal (MWFA); and Facility Deactivation, Decommissioning, and Material Disposition (FDDMDFA). Brief descriptions of CMST-CP projects funded in FY95 are presented

  9. Characterization, monitoring, and sensor technology crosscutting program: Technology summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    The purpose of the Characterization, Monitoring, and Sensor Technology Crosscutting Program (CMST-CP) is to deliver appropriate characterization, monitoring, and sensor technology (CMST) to the Office of Waste Management (EM-30), the Office of Environmental Restoration (EM-40), and the Office of Facility Transition and Management (EM-60). The technology development must also be cost effective and appropriate to EM-30/40/60 needs. Furthermore, the required technologies must be delivered and implemented when needed. Accordingly, and to ensure that available DOE and other national resources are focused an the most pressing needs, management of the technology development is concentrated on the following Focus Areas: Contaminant Plume Containment and Remediation (PFA); Landfill Stabilization (LSFA); High-Level Waste Tank Remediation (TFA); Mixed Waste Characterization, Treatment, and Disposal (MWFA); and Facility Deactivation, Decommissioning, and Material Disposition (FDDMDFA). Brief descriptions of CMST-CP projects funded in FY95 are presented.

  10. Pharmacology Portal: An Open Database for Clinical Pharmacologic Laboratory Services.

    Science.gov (United States)

    Karlsen Bjånes, Tormod; Mjåset Hjertø, Espen; Lønne, Lars; Aronsen, Lena; Andsnes Berg, Jon; Bergan, Stein; Otto Berg-Hansen, Grim; Bernard, Jean-Paul; Larsen Burns, Margrete; Toralf Fosen, Jan; Frost, Joachim; Hilberg, Thor; Krabseth, Hege-Merete; Kvan, Elena; Narum, Sigrid; Austgulen Westin, Andreas

    2016-01-01

    More than 50 Norwegian public and private laboratories provide one or more analyses for therapeutic drug monitoring or testing for drugs of abuse. Practices differ among laboratories, and analytical repertoires can change rapidly as new substances become available for analysis. The Pharmacology Portal was developed to provide an overview of these activities and to standardize the practices and terminology among laboratories. The Pharmacology Portal is a modern dynamic web database comprising all available analyses within therapeutic drug monitoring and testing for drugs of abuse in Norway. Content can be retrieved by using the search engine or by scrolling through substance lists. The core content is a substance registry updated by a national editorial board of experts within the field of clinical pharmacology. This ensures quality and consistency regarding substance terminologies and classification. All laboratories publish their own repertoires in a user-friendly workflow, adding laboratory-specific details to the core information in the substance registry. The user management system ensures that laboratories are restricted from editing content in the database core or in repertoires within other laboratory subpages. The portal is for nonprofit use, and has been fully funded by the Norwegian Medical Association, the Norwegian Society of Clinical Pharmacology, and the 8 largest pharmacologic institutions in Norway. The database server runs an open-source content management system that ensures flexibility with respect to further development projects, including the potential expansion of the Pharmacology Portal to other countries. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.

  11. Editor's welcome, PORTAL, Vol. 1, No. 1, January 2004

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2004-01-01

    Full Text Available Welcome to the inaugural issue of PORTAL On behalf of the Executive Editorial Committee of PORTAL Journal of Multidisciplinary International Studies, it is a great pleasure to announce the virtual birth of this fully peer-reviewed journal under the auspices of UTSePress, the exciting new electronic publishing enterprise housed at the central library at the University of Technology, Sydney (UTS, Australia. PORTAL itself is edited by staff from the Institute for International Studies, a dynamic research and teaching centre at UTS. The launch of PORTAL's inaugural issue will take place simultaneously in Sydney, Australia, and Guadalajara, México, on January 28 (Sydney / 27 (Guadalajara 2004. The trans-Pacific axial enabling this twin launch is emblematic of the many axes of dialogue that, it is to be hoped, will characterize the content and reception of this and future issues of Portal. We are grateful to the many people at the Center for Social Sciences and Humanities at la Universidad de Guadalajara, México, for their provision of the technologies and tequila that will facilitate Portal's digital launch in a different space and timezone to its 'homebirth' in Sydney, Australia. As PORTAL's 'Focus and Scope' statement indicates, the journal is dedicated to publishing scholarship by practitioners of-and dissenters from-international, regional, area, migration, and ethnic studies. PORTAL is also committed to providing a space for cultural producers interested in the internationalization of cultures. With these aims in mind we have conceived PORTAL as a "multidisciplinary venture," to use Michel Chaouli's words. That is, PORTAL signifies "a place where researchers [and cultural producers] are exposed to different ways of posing questions and proffering answers, without creating out of their differing disciplinary languages a common theoretical or methodological pidgin" (2003, p. 57. Our hope is that scholars working in the humanities

  12. Characterization, Monitoring and Sensor Technology Integrated Program

    International Nuclear Information System (INIS)

    1993-01-01

    This booklet contains summary sheets that describe FY 1993 characterization, monitoring, and sensor technology (CMST) development projects. Currently, 32 projects are funded, 22 through the OTD Characterization, Monitoring, and Sensor Technology Integrated Program (CMST-IP), 8 through the OTD Program Research and Development Announcement (PRDA) activity managed by the Morgantown Energy Technology Center (METC), and 2 through Interagency Agreements (IAGs). This booklet is not inclusive of those CMST projects which are funded through Integrated Demonstrations (IDs) and other Integrated Programs (IPs). The projects are in six areas: Expedited Site Characterization; Contaminants in Soils and Groundwater; Geophysical and Hydrogeological Measurements; Mixed Wastes in Drums, Burial Grounds, and USTs; Remediation, D ampersand D, and Waste Process Monitoring; and Performance Specifications and Program Support. A task description, technology needs, accomplishments and technology transfer information is given for each project

  13. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  14. Corrosion monitoring using FSM technology

    International Nuclear Information System (INIS)

    Strommen, R.; Horn, H.; Gartland, P.O.; Wold, K.; Haroun, M.

    1995-01-01

    FSM is a non-intrusive monitoring technique based on a patented principle, developed for the purpose of detection and monitoring of both general and localized corrosion, erosion, and cracking in steel and metal structures, piping systems, and vessels. Since 1991, FSM has been used for a wide range of applications, including for buried and open pipelines, process piping offshore, subsea pipelines and flowlines, applications in the nuclear power industry, and in materials, research in general. This paper describes typical applications of the FSM technology, and presents operational experience from some of the land-based and subsea installations. The paper also describes recent enhancements in the FSM technology and in the analysis of FSM readings, allowing for monitoring and detailed quantification of pitting and mesa corrosion, and of corrosion in welds

  15. The NexStar evolution and SkyPortal user's guide

    CERN Document Server

    Chen, James L

    2016-01-01

    This book serves as a comprehensive guide for using a Nexstar Evolution mount with WiFi SkyPortal control, walking the reader through the process for aligning and operating the system from a tablet or smartphone. The next generation Go-To mount from Celestron, this is compatible not only with the Nextstar Evolution but also with older mounts. It is the ideal resource for anyone who owns, or is thinking of owning, a Nexstar Evolution telescope, or adapting their existing Celestron mount. Pros and cons of the system are thoroughly covered with a critical depth that addresses any possible question by users. Beginning with a brief history of Go-To telescopes and the genesis of this still new technology, the author covers every aspect of the newly expanding capability in observing. This includes the associated Sky Portal smartphone and tablet application, the transition from the original Nexstar GoTo system to the new SkyPortal system, the use of the Sky Portal application with its Sky Safari 4 basic software and ...

  16. submitter The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    CERN Document Server

    Antonuccio, V; Becciani, U; Bonanno, D L; Bonanno, G; Bongiovanni, D; Fallica, P G; Garozzo, S; Grillo, A; La Rocca, P; Leonora, E; Longhitano, F; Lo Presti, D; Marano, D; Parasole, O; Pugliatti, C; Randazzo, N; Riggi, F; Riggi, S; Romeo, G; Romeo, M; Russo, G V; Santagati, G; Timpanaro, M C; Valvo, G

    2017-01-01

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype $(6×3×7 m^3)$ for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as o...

  17. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  18. New technologies for monitoring nuclear materials

    International Nuclear Information System (INIS)

    Moran, B.W.

    1993-01-01

    This paper describes new technologies for monitoring the continued presence of nuclear materials that are being evaluated in Oak Ridge, Tennessee, to reduce the effort, cost, and employee exposures associated with conducting nuclear material inventories. These technologies also show promise for the international safeguarding of process systems and nuclear materials in storage, including spent fuels. The identified systems are based on innovative technologies that were not developed for safeguards applications. These advanced technologies include passive and active sensor systems based on optical materials, inexpensive solid-state radiation detectors, dimensional surface characterization, and digital color imagery. The passive sensor systems use specialized scintillator materials coupled to optical-fiber technologies that not only are capable of measuring radioactive emissions but also are capable of measuring or monitoring pressure, weight, temperature, and source location. Small, durable solid-state gamma-ray detection devices, whose components are estimated to cost less than $25 per unit, can be implemented in a variety of configurations and can be adapted to enhance existing monitoring systems. Variations in detector design have produced significantly different system capabilities. Dimensional surface characterization and digital color imaging are applications of developed technologies that are capable of motion detection, item surveillance, and unique identification of items

  19. Pediatric portal hypertension

    Science.gov (United States)

    Vogel, Clarissa Barbon

    2017-01-01

    Abstract: Pediatric portal hypertension management is a team approach between the patient, the patient's family, the primary caregiver, and specialty providers. Evidence-based practice guidelines have not been established in pediatrics. This article serves as a review for the primary care NP in the management of pediatric portal hypertension, discussing the etiology, pathophysiology, and clinical presentation of pediatric portal hypertension, diagnostic tests, and treatment and management options. PMID:28406835

  20. Impact of spectral smoothing on gamma radiation portal alarm probabilities

    International Nuclear Information System (INIS)

    Burr, T.; Hamada, M.; Hengartner, N.

    2011-01-01

    Gamma detector counts are included in radiation portal monitors (RPM) to screen for illicit nuclear material. Gamma counts are sometimes smoothed to reduce variance in the estimated underlying true mean count rate, which is the 'signal' in our context. Smoothing reduces total error variance in the estimated signal if the bias that smoothing introduces is more than offset by the variance reduction. An empirical RPM study for vehicle screening applications is presented for unsmoothed and smoothed gamma counts in low-resolution plastic scintillator detectors and in medium-resolution NaI detectors. - Highlights: → We evaluate options for smoothing counts from gamma detectors deployed for portal monitoring. → A new multiplicative bias correction (MBC) is shown to reduce bias in peak and valley regions. → Performance is measured using mean squared error and detection probabilities for sources. → Smoothing with the MBC improves detection probabilities and the mean squared error.

  1. Web portal on environmental sciences "ATMOS''

    Directory of Open Access Journals (Sweden)

    E. P. Gordov

    2006-01-01

    Full Text Available The developed under INTAS grant web portal ATMOS (http://atmos.iao.ru and http://atmos.scert.ru makes available to the international research community, environmental managers, and the interested public, a bilingual information source for the domain of Atmospheric Physics and Chemistry, and the related application domain of air quality assessment and management. It offers access to integrated thematic information, experimental data, analytical tools and models, case studies, and related information and educational resources compiled, structured, and edited by the partners into a coherent and consistent thematic information resource. While offering the usual components of a thematic site such as link collections, user group registration, discussion forum, news section etc., the site is distinguished by its scientific information services and tools: on-line models and analytical tools, and data collections and case studies together with tutorial material. The portal is organized as a set of interrelated scientific sites, which addressed basic branches of Atmospheric Sciences and Climate Modeling as well as the applied domains of Air Quality Assessment and Management, Modeling, and Environmental Impact Assessment. Each scientific site is open for external access information-computational system realized by means of Internet technologies. The main basic science topics are devoted to Atmospheric Chemistry, Atmospheric Spectroscopy and Radiation, Atmospheric Aerosols, Atmospheric Dynamics and Atmospheric Models, including climate models. The portal ATMOS reflects current tendency of Environmental Sciences transformation into exact (quantitative sciences and is quite effective example of modern Information Technologies and Environmental Sciences integration. It makes the portal both an auxiliary instrument to support interdisciplinary projects of regional environment and extensive educational resource in this important domain.

  2. Rancang Bangun Portal E-Commerce Semarang-Handycraft Berorientasi Obyek

    Directory of Open Access Journals (Sweden)

    Sinta Tridian Galih

    2012-01-01

    Full Text Available Number of  emerging  Small  and  Medium  Enterprises  (SMEs  in  Indonesia  has  not  been  matched  with  optimal  performance.  Manyproblems  arise  such  as  difficulty  in  marketing  products  and  limited  costs  for  marketing.  This  problem  can  be  overcome  by  utilizingInternet technology to build e-commerce portal. Portal help online marketing with no borders zone, facilitate for searching a consumer,can automate the promotion and business transactions that can help win the competition.In this research, to be built e -commerce portalSemarang-Handycraft. Design of e-commerce portal is using system development methodologies Model Driven Development (MDDand UML modeling language (Unified Modeling Language which is a visual language for modeling object -oriented language and byusing the  Open Source  Content Management  Systems  that  is  called  Joomla  and  using  e-commerce  modules Virtuemart.  Produced  ecommerce portal that can provide information with better quality and can be accessed at http://semarang-handycraft.cz.cc, which is a newalternative  for  the  production  of  marketing  handicraft  products  of  SMEs  in  Semarang.  For  security  and  convinience  of   informationretrieval in e-commerce portal is divided into several access rights, ie rights of access to regular visitors, members and administratorsKeywords: E-commerce; Portals; UML; Object-oriented

  3. Sandia technology. Volume 13, number 2 Special issue: verification of arms control treaties

    International Nuclear Information System (INIS)

    1989-01-01

    Nuclear deterrence, a cornerstone of US national security policy, has helped prevent global conflict for over 40 years. The DOE and DoD share responsibility for this vital part of national security. The US will continue to rely on nuclear deterrence for the foreseeable future. In the late 1950s, Sandia developed satellite-borne nuclear burst detection systems to support the treaty banning atmospheric nuclear tests. This activity has continued to expand and diversify. When the Non-Proliferation Treaty was ratified in 1970, we began to develop technologies to protect nuclear materials from falling into unauthorized hands. This program grew and now includes systems for monitoring the movement and storage of nuclear materials, detecting tampering, and transmiting sensitive data securely. In the late 1970s, negotiations to further limit underground nuclear testing were being actively pursued. In less than 18 months, we fielded the National Seismic Station, an unattended observatory for in-country monitoring of nuclear tests. In the mid-l980s, arms-control interest shifted to facility monitoring and on-site inspection. Our Technical On-site Inspection Facility is the national test bed for perimeter and portal monitoring technology and the prototype for the inspection portal that was recently installed in the USSR under the Intermediate-Range Nuclear Forces accord. The articles in the special issue of Sundiu Technology describe some of our current contributions to verification technology. This work supports the US policy to seek realistic arms control agreements while maintaining our national security.

  4. Origins of Portal Hypertension in Nonalcoholic Fatty Liver Disease.

    Science.gov (United States)

    Baffy, Gyorgy

    2018-03-01

    Nonalcoholic fatty liver disease (NAFLD) advanced to cirrhosis is often complicated by clinically significant portal hypertension, which is primarily caused by increased intrahepatic vascular resistance. Liver fibrosis has been identified as a critical determinant of this process. However, there is evidence that portal venous pressure may begin to rise in the earliest stages of NAFLD when fibrosis is far less advanced or absent. The biological and clinical significance of these early changes in sinusoidal homeostasis remains unclear. Experimental and human observations indicate that sinusoidal space restriction due to hepatocellular lipid accumulation and ballooning may impair sinusoidal flow and generate shear stress, increasingly disrupting sinusoidal microcirculation. Sinusoidal endothelial cells, hepatic stellate cells, and Kupffer cells are key partners of hepatocytes affected by NAFLD in promoting endothelial dysfunction through enhanced contractility, capillarization, adhesion and entrapment of blood cells, extracellular matrix deposition, and neovascularization. These biomechanical and rheological changes are aggravated by a dysfunctional gut-liver axis and splanchnic vasoregulation, culminating in fibrosis and clinically significant portal hypertension. We may speculate that increased portal venous pressure is an essential element of the pathogenesis across the entire spectrum of NAFLD. Improved methods of noninvasive portal venous pressure monitoring will hopefully give new insights into the pathobiology of NAFLD and help efforts to identify patients at increased risk for adverse outcomes. In addition, novel drug candidates targeting reversible components of aberrant sinusoidal circulation may prevent progression in NAFLD.

  5. New technologies in nuclear power plant monitoring and diagnosis

    International Nuclear Information System (INIS)

    Turkcan, E.; Verhoef, J.P.; Ciftcioglu, O.

    1996-01-01

    Several representative new technologies being introduce for monitoring and diagnosis in nuclear power plants (NPP) are presented in this paper. In Sec. 2, the Kalman filtering is briefly described and it relevance to conventional time series analysis methods are emphasized. In this respect, its NPP monitoring and fault diagnosis implementations are given and the important features are pointed out. In Sec. 3, the NN technology is briefly described and the scope is focused on the NPP monitoring and fault diagnosis implementations. In Sec. 4, the wavelet technology is briefly described and the utilization of this technology in Nuclear Technology is exemplified. In this respect, also the prospective role of this technology for real-time monitoring and fault diagnosis is revealed. (author). 33 refs, 6 figs

  6. New technologies in nuclear power plant monitoring and diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Turkcan, E; Verhoef, J P [Netherlands Energy Research Foundation (ECN), Petten (Netherlands); Ciftcioglu, O [Istanbul Technical Univ., Istanbul (Turkey). Nuclear Power Dept.

    1997-12-31

    Several representative new technologies being introduce for monitoring and diagnosis in nuclear power plants (NPP) are presented in this paper. In Sec. 2, the Kalman filtering is briefly described and it relevance to conventional time series analysis methods are emphasized. In this respect, its NPP monitoring and fault diagnosis implementations are given and the important features are pointed out. In Sec. 3, the NN technology is briefly described and the scope is focused on the NPP monitoring and fault diagnosis implementations. In Sec. 4, the wavelet technology is briefly described and the utilization of this technology in Nuclear Technology is exemplified. In this respect, also the prospective role of this technology for real-time monitoring and fault diagnosis is revealed. (author). 33 refs, 6 figs.

  7. Galaxy Portal: interacting with the galaxy platform through mobile devices.

    Science.gov (United States)

    Børnich, Claus; Grytten, Ivar; Hovig, Eivind; Paulsen, Jonas; Čech, Martin; Sandve, Geir Kjetil

    2016-06-01

    : We present Galaxy Portal app, an open source interface to the Galaxy system through smart phones and tablets. The Galaxy Portal provides convenient and efficient monitoring of job completion, as well as opportunities for inspection of results and execution history. In addition to being useful to the Galaxy community, we believe that the app also exemplifies a useful way of exploiting mobile interfaces for research/high-performance computing resources in general. The source is freely available under a GPL license on GitHub, along with user documentation and pre-compiled binaries and instructions for several platforms: https://github.com/Tarostar/QMLGalaxyPortal It is available for iOS version 7 (and newer) through the Apple App Store, and for Android through Google Play for version 4.1 (API 16) or newer. geirksa@ifi.uio.no. © The Author 2016. Published by Oxford University Press.

  8. Engineering and Computing Portal to Solve Environmental Problems

    Science.gov (United States)

    Gudov, A. M.; Zavozkin, S. Y.; Sotnikov, I. Y.

    2018-01-01

    This paper describes architecture and services of the Engineering and Computing Portal, which is considered to be a complex solution that provides access to high-performance computing resources, enables to carry out computational experiments, teach parallel technologies and solve computing tasks, including technogenic safety ones.

  9. Patient portal readiness among postpartum patients in a safety net setting.

    Science.gov (United States)

    Wieland, Daryl; Gibeau, Anne; Dewey, Caitlin; Roshto, Melanie; Frankel, Hilary

    2017-07-05

    Maternity patients interact with the healthcare system over an approximately ten-month interval, requiring multiple visits, acquiring pregnancy-specific education, and sharing health information among providers. Many features of a web-based patient portal could help pregnant women manage their interactions with the healthcare system; however, it is unclear whether pregnant women in safety-net settings have the resources, skills or interest required for portal adoption. In this study of postpartum patients in a safety net hospital, we aimed to: (1) determine if patients have the technical resources and skills to access a portal, (2) gain insight into their interest in health information, and (3) identify the perceived utility of portal features and potential barriers to adoption. We developed a structured questionnaire to collect demographics from postpartum patients and measure use of technology and the internet, self-reported literacy, interest in health information, awareness of portal functions, and perceived barriers to use. The questionnaire was administered in person to women in an inpatient setting. Of the 100 participants surveyed, 95% reported routine internet use and 56% used it to search for health information. Most participants had never heard of a patient portal, yet 92% believed that the portal functions were important. The two most appealing functions were to check results and manage appointments. Most participants in this study have the required resources such as a device and familiarity with the internet to access a patient portal including an interest in interacting with a healthcare institution via electronic means. Pregnancy is a critical episode of care where active engagement with the healthcare system can influence outcomes. Healthcare systems and portal developers should consider ways to tailor a portal to address the specific health needs of a maternity population including those in a safety net setting.

  10. Integration of wireless sensor networks into cyberinfrastructure for monitoring Hawaiian "mountain-to-sea" environments.

    Science.gov (United States)

    Kido, Michael H; Mundt, Carsten W; Montgomery, Kevin N; Asquith, Adam; Goodale, David W; Kaneshiro, Kenneth Y

    2008-10-01

    Monitoring the complex environmental relationships and feedbacks of ecosystems on catchment (or mountain)-to-sea scales is essential for social systems to effectively deal with the escalating impacts of expanding human populations globally on watersheds. However, synthesis of emerging technologies into a robust observing platform for the monitoring of coupled human-natural environments on extended spatial scales has been slow to develop. For this purpose, the authors produced a new cyberinfrastructure for environmental monitoring which successfully merged the use of wireless sensor technologies, grid computing with three-dimensional (3D) geospatial data visualization/exploration, and a secured internet portal user interface, into a working prototype for monitoring mountain-to-sea environments in the high Hawaiian Islands. A use-case example is described in which native Hawaiian residents of Waipa Valley (Kauai) utilized the technology to monitor the effects of regional weather variation on surface water quality/quantity response, to better understand their local hydrologic cycle, monitor agricultural water use, and mitigate the effects of lowland flooding.

  11. Best Practices for Making Scientific Data Discoverable and Accessible through Integrated, Standards-Based Data Portals

    Science.gov (United States)

    Lucido, J. M.

    2013-12-01

    Scientists in the fields of hydrology, geophysics, and climatology are increasingly using the vast quantity of publicly-available data to address broadly-scoped scientific questions. For example, researchers studying contamination of nearshore waters could use a combination of radar indicated precipitation, modeled water currents, and various sources of in-situ monitoring data to predict water quality near a beach. In discovering, gathering, visualizing and analyzing potentially useful data sets, data portals have become invaluable tools. The most effective data portals often aggregate distributed data sets seamlessly and allow multiple avenues for accessing the underlying data, facilitated by the use of open standards. Additionally, adequate metadata are necessary for attribution, documentation of provenance and relating data sets to one another. Metadata also enable thematic, geospatial and temporal indexing of data sets and entities. Furthermore, effective portals make use of common vocabularies for scientific methods, units of measure, geologic features, chemical, and biological constituents as they allow investigators to correctly interpret and utilize data from external sources. One application that employs these principles is the National Ground Water Monitoring Network (NGWMN) Data Portal (http://cida.usgs.gov/ngwmn), which makes groundwater data from distributed data providers available through a single, publicly accessible web application by mediating and aggregating native data exposed via web services on-the-fly into Open Geospatial Consortium (OGC) compliant service output. That output may be accessed either through the map-based user interface or through the aforementioned OGC web services. Furthermore, the Geo Data Portal (http://cida.usgs.gov/climate/gdp/), which is a system that provides users with data access, subsetting and geospatial processing of large and complex climate and land use data, exemplifies the application of International Standards

  12. VisPortal: Deploying grid-enabled visualization tools through a web-portal interface

    Energy Technology Data Exchange (ETDEWEB)

    Bethel, Wes; Siegerist, Cristina; Shalf, John; Shetty, Praveenkumar; Jankun-Kelly, T.J.; Kreylos, Oliver; Ma, Kwan-Liu

    2003-06-09

    The LBNL/NERSC Visportal effort explores ways to deliver advanced Remote/Distributed Visualization (RDV) capabilities through a Grid-enabled web-portal interface. The effort focuses on latency tolerant distributed visualization algorithms, GUI designs that are more appropriate for the capabilities of web interfaces, and refactoring parallel-distributed applications to work in a N-tiered component deployment strategy. Most importantly, our aim is to leverage commercially-supported technology as much as possible in order to create a deployable, supportable, and hence viable platform for delivering grid-based visualization services to collaboratory users.

  13. Índice de congestão portal e a ocorrência de trombose portal pós-dape Portal congestion and thrombosis after EDS

    Directory of Open Access Journals (Sweden)

    Fabio Gonçalves Ferreira

    2005-08-01

    Full Text Available OBJETIVO: Comparar os dados obtidos pela ultra-sonografia com doppler no pré-operatório de esquistossomóticos submetidos à desconexão ázigo-portal com esplenectomia (DAPE, calculando o índice de congestão portal, e sua correlação com a trombose portal no pós-operatório. MÉTODOS: Foram estudados 65 pacientes submetidos à DAPE por hipertensão portal esquistossomótica com antecedente de hemorragia digestiva, divididos em dois grupos: Grupo A (28 pacientes que não desenvolveram trombose portal pós-operatória e Grupo B (37 pacientes com trombose portal no pós-operatório. Analisaram-se através de ultra-sonografia com doppler no pré-operatório os seguintes parâmetros da veia porta: diâmetro, área, velocidade média de fluxo do sangue, fluxo de sangue, e estabeleceu-se o índice de congestão portal. RESULTADOS: O diâmetro, área e o fluxo da veia porta foram maiores no grupo B (média de 1,52 cm; 1,77 cm² e 2533,12 ml/min em relação ao grupo A (média de 1,33 cm; 1,44 cm² e 1609,03 ml/min com p = 0,03; 0,03 e 0,04 respectivamente. O índice de congestão portal não foi estatisticamente significativo na comparação dos dois grupos (p = 0,07. CONCLUSÃO: O índice de congestão portal obtido no pré-operatório através da ultra-sonografia com doppler não se mostrou preditivo de trombose portal no pós-operatório dos doentes estudados.BACKGROUND: The study compared the preoperative portal vein congestion index estimated by Doppler ultrasound and the postoperative portal vein thrombosis of patients submitted to esophagogastric devascularization and splenectomy (EDS. METHODS: 65 patients with portal hypertension due to schistosomiasis and previous gastrointestinal bleeding submitted to EDS were divided into two groups: GROUP A (28 patients without postoperative portal vein thrombosis and GROUP B (37 patients with postoperative portal vein thrombosis. The following parameters of preoperative Doppler ultrasound of the

  14. Biology of portal hypertension.

    Science.gov (United States)

    McConnell, Matthew; Iwakiri, Yasuko

    2018-02-01

    Portal hypertension develops as a result of increased intrahepatic vascular resistance often caused by chronic liver disease that leads to structural distortion by fibrosis, microvascular thrombosis, dysfunction of liver sinusoidal endothelial cells (LSECs), and hepatic stellate cell (HSC) activation. While the basic mechanisms of LSEC and HSC dysregulation have been extensively studied, the role of microvascular thrombosis and platelet function in the pathogenesis of portal hypertension remains to be clearly characterized. As a secondary event, portal hypertension results in splanchnic and systemic arterial vasodilation, leading to the development of a hyperdynamic circulatory syndrome and subsequently to clinically devastating complications including gastroesophageal varices and variceal hemorrhage, hepatic encephalopathy from the formation of portosystemic shunts, ascites, and renal failure due to the hepatorenal syndrome. This review article discusses: (1) mechanisms of sinusoidal portal hypertension, focusing on HSC and LSEC biology, pathological angiogenesis, and the role of microvascular thrombosis and platelets, (2) the mesenteric vasculature in portal hypertension, and (3) future directions for vascular biology research in portal hypertension.

  15. Extrahepatic portal hypertension in childhood

    International Nuclear Information System (INIS)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-01-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood. (author)

  16. Current status of technology development on remote monitoring system

    International Nuclear Information System (INIS)

    Yoon, Wan Ki; Lee, Y. K.; Lee, Y. D.; Na, W. W.

    1997-03-01

    IAEA is planning to perform the remote monitoring system in nuclear facility in order to reinforce the economical and efficient inspection. National lab. in U.S. is developing the corresponding core technology and field trial will be done to test the remote monitoring system by considering the case that it replace the current safeguards system. U.S. setup the International Remote Monitoring Project to develop the technology. IAEA makes up remote monitoring team and setup the detail facility to apply remote monitoring system. Therefore, early participation in remote monitoring technology development will make contribution in international remote monitoring system and increase the transparency and confidence in domestic nuclear activities. (author). 12 refs., 20 figs

  17. Usability of Discovery Portals

    NARCIS (Netherlands)

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals

  18. The Knowledge Portal

    Data.gov (United States)

    Office of Personnel Management — Information on various courses, as well as personal data of employees and training records from The Knowledge Portal (TKP), a web-based training portal used for the...

  19. The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    Energy Technology Data Exchange (ETDEWEB)

    Antonuccio, V. [INAF - Osservatorio Astrofisico di Catania (Italy); Bandieramonte, M. [CERN, Geneva (Switzerland); Becciani, U. [INAF - Osservatorio Astrofisico di Catania (Italy); Bonanno, D.L., E-mail: danilo.bonanno@ct.infn.it [INFN Sezione di Catania, Catania (Italy); Bonanno, G. [INAF - Osservatorio Astrofisico di Catania (Italy); Bongiovanni, D. [INFN Sezione di Catania, Catania (Italy); Fallica, P.G. [STMicroelectronics, Catania (Italy); Garozzo, S.; Grillo, A. [INAF - Osservatorio Astrofisico di Catania (Italy); La Rocca, P. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Leonora, E.; Longhitano, F. [INFN Sezione di Catania, Catania (Italy); Lo Presti, D. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Marano, D. [INAF - Osservatorio Astrofisico di Catania (Italy); Parasole, O. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Pugliatti, C. [Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Randazzo, N. [INFN Sezione di Catania, Catania (Italy); Riggi, F. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Riggi, S. [INAF - Osservatorio Astrofisico di Catania (Italy); INFN Sezione di Catania, Catania (Italy); Romeo, G. [INAF - Osservatorio Astrofisico di Catania (Italy); and others

    2017-02-11

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype (6×3×7 m{sup 3}) for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as on the preliminary results obtained with the first detection planes.

  20. The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    Science.gov (United States)

    Antonuccio, V.; Bandieramonte, M.; Becciani, U.; Bonanno, D. L.; Bonanno, G.; Bongiovanni, D.; Fallica, P. G.; Garozzo, S.; Grillo, A.; La Rocca, P.; Leonora, E.; Longhitano, F.; Lo Presti, D.; Marano, D.; Parasole, O.; Pugliatti, C.; Randazzo, N.; Riggi, F.; Riggi, S.; Romeo, G.; Romeo, M.; Russo, G. V.; Santagati, G.; Timpanaro, M. C.; Valvo, G.

    2017-02-01

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype (6×3×7 m3) for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as on the preliminary results obtained with the first detection planes.

  1. Portal imaging practice patterns of children's oncology group institutions: Dosimetric assessment and recommendations for minimizing unnecessary exposure

    International Nuclear Information System (INIS)

    Olch, Arthur J.; Geurts, Mark; Thomadsen, Bruce; Famiglietti, Robin; Chang, Eric L.

    2007-01-01

    Purpose: To determine and analyze the dosimetric consequences of current portal imaging practices for pediatric patients, and make specific recommendations for reducing exposure from portal imaging procedures. Methods and Materials: A survey was sent to approximately 250 Children's Oncology Group (COG) member institutions asking a series of questions about their portal imaging practices. Three case studies are presented with dosimetric analysis to illustrate the magnitude of unintended dose received by nontarget tissues using the most common techniques from the survey. Results: The vast majority of centers use double-exposure portal image techniques with a variety of open field margins. Only 17% of portal images were obtained during treatment, and for other imaging methods, few centers subtract monitor units from the treatment delivery. The number of monitor units used was nearly the same regardless of imager type, including electronic portal imaging devices. Eighty-six percent imaged all fields the first week and 17% imaged all fields every week. An additional 1,112 cm 3 of nontarget tissue received 1 Gy in one of the example cases. Eight new recommendations are made, which will lower nontarget radiation doses with minimal impact on treatment verification accuracy. Conclusion: Based on the survey, changes can be made in portal imaging practices that will lower nontarget doses. It is anticipated that treatment verification accuracy will be minimally affected. Specific recommendations made to decrease the imaging dose and help lower the rate of radiation-induced secondary cancers in children are proposed for inclusion in future COG protocols using radiation therapy

  2. Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART)

    International Nuclear Information System (INIS)

    Guan, Huaiqun; Zhu, Yunping

    1998-01-01

    Although electronic portal imaging devices (EPIDs) are efficient tools for radiation therapy verification, they only provide images of overlapped anatomic structures. We investigated using a fluorescent screen/CCD-based EPID, coupled with a novel multi-level scheme algebraic reconstruction technique (MLS-ART), for a feasibility study of portal computed tomography (CT) reconstructions. The CT images might be useful for radiation treatment planning and verification. We used an EPID, set it to work at the linear dynamic range and collimated 6 MV photons from a linear accelerator to a slit beam of 1 cm wide and 25 cm long. We performed scans under a total of ∼200 monitor units (MUs) for several phantoms in which we varied the number of projections and MUs per projection. The reconstructed images demonstrated that using the new MLS-ART technique megavoltage portal CT with a total of 200 MUs can achieve a contrast detectibility of ∼2.5% (object size 5mmx5mm) and a spatial resolution of 2.5 mm. (author)

  3. Genomics Portals: integrative web-platform for mining genomics data.

    Science.gov (United States)

    Shinde, Kaustubh; Phatak, Mukta; Johannes, Freudenberg M; Chen, Jing; Li, Qian; Vineet, Joshi K; Hu, Zhen; Ghosh, Krishnendu; Meller, Jaroslaw; Medvedovic, Mario

    2010-01-13

    A large amount of experimental data generated by modern high-throughput technologies is available through various public repositories. Our knowledge about molecular interaction networks, functional biological pathways and transcriptional regulatory modules is rapidly expanding, and is being organized in lists of functionally related genes. Jointly, these two sources of information hold a tremendous potential for gaining new insights into functioning of living systems. Genomics Portals platform integrates access to an extensive knowledge base and a large database of human, mouse, and rat genomics data with basic analytical visualization tools. It provides the context for analyzing and interpreting new experimental data and the tool for effective mining of a large number of publicly available genomics datasets stored in the back-end databases. The uniqueness of this platform lies in the volume and the diversity of genomics data that can be accessed and analyzed (gene expression, ChIP-chip, ChIP-seq, epigenomics, computationally predicted binding sites, etc), and the integration with an extensive knowledge base that can be used in such analysis. The integrated access to primary genomics data, functional knowledge and analytical tools makes Genomics Portals platform a unique tool for interpreting results of new genomics experiments and for mining the vast amount of data stored in the Genomics Portals backend databases. Genomics Portals can be accessed and used freely at http://GenomicsPortals.org.

  4. Splenic embolization in cirrhotic patients with portal hypertension. US findings

    Energy Technology Data Exchange (ETDEWEB)

    Falappa, P G; Cotroneo, A R; De Cinque, M; Maresca, G; Patane' , D

    1988-01-01

    Over the last four years the authors performed transcatheter embolization of the splenic artery by Gianturco coils in 32 consecutive cirrhotic patients with portal hypertension, splenomegaly, cytopenia and gastro-esophageal varices endoscopically proved. This procedure was especially useful for treatement of splenomegaly and cytopenia because a constant reduction of spleen dimensions and increase in platelet count were registered. The effectiveness of transcatheter embolization and follow-up are based on clinic, hematologic and sonographic findings. Sonographic monitoring is believed to be very useful both to evaluate splenomegaly and signs of portal hypertension and to reveal splenic complications (abscesses). Severe complications have been never registered. 21 refs.

  5. Wall shear stress in portal vein of cirrhotic patients with portal hypertension.

    Science.gov (United States)

    Wei, Wei; Pu, Yan-Song; Wang, Xin-Kai; Jiang, An; Zhou, Rui; Li, Yu; Zhang, Qiu-Juan; Wei, Ya-Juan; Chen, Bin; Li, Zong-Fang

    2017-05-14

    To investigate wall shear stress (WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. Idealized portal vein (PV) system models were reconstructed with different angles of the PV-splenic vein (SV) and superior mesenteric vein (SMV)-SV. Patient-specific models were created according to enhanced computed tomography images. WSS was simulated by using a finite-element analyzer, regarding the blood as a Newtonian fluid and the vessel as a rigid wall. Analysis was carried out to compare the WSS in the portal hypertension group with that in healthy controls. For the idealized models, WSS in the portal hypertension group (0-10 dyn/cm 2 ) was significantly lower than that in the healthy controls (10-20 dyn/cm 2 ), and low WSS area (0-1 dyn/cm 2 ) only occurred in the left wall of the PV in the portal hypertension group. Different angles of PV-SV and SMV-SV had different effects on the magnitude and distribution of WSS, and low WSS area often occurred in smaller PV-SV angle and larger SMV-SV angle. In the patient-specific models, WSS in the cirrhotic patients with portal hypertension (10.13 ± 1.34 dyn/cm 2 ) was also significantly lower than that in the healthy controls ( P portal hypertension, the low WSS area extended to wider levels and the magnitude of WSS reached lower levels, thereby being more prone to disturbed flow occurrence. Cirrhotic patients with portal hypertension show dramatic hemodynamic changes with lower WSS and greater potential for disturbed flow, representing a possible causative factor of PV thrombosis.

  6. Development of a Ground Water Data Portal for Interoperable Data Exchange within the U.S. National Ground Water Monitoring Network and Beyond

    Science.gov (United States)

    Booth, N. L.; Brodaric, B.; Lucido, J. M.; Kuo, I.; Boisvert, E.; Cunningham, W. L.

    2011-12-01

    The need for a national groundwater monitoring network within the United States is profound and has been recognized by organizations outside government as a major data gap for managing ground-water resources. Our country's communities, industries, agriculture, energy production and critical ecosystems rely on water being available in adequate quantity and suitable quality. To meet this need the Subcommittee on Ground Water, established by the Federal Advisory Committee on Water Information, created a National Ground Water Monitoring Network (NGWMN) envisioned as a voluntary, integrated system of data collection, management and reporting that will provide the data needed to address present and future ground-water management questions raised by Congress, Federal, State and Tribal agencies and the public. The NGWMN Data Portal is the means by which policy makers, academics and the public will be able to access ground water data through one seamless web-based application from disparate data sources. Data systems in the United States exist at many organizational and geographic levels and differing vocabulary and data structures have prevented data sharing and reuse. The data portal will facilitate the retrieval of and access to groundwater data on an as-needed basis from multiple, dispersed data repositories allowing the data to continue to be housed and managed by the data provider while being accessible for the purposes of the national monitoring network. This work leverages Open Geospatial Consortium (OGC) data exchange standards and information models. To advance these standards for supporting the exchange of ground water information, an OGC Interoperability Experiment was organized among international participants from government, academia and the private sector. The experiment focused on ground water data exchange across the U.S. / Canadian border. WaterML2.0, an evolving international standard for water observations, encodes ground water levels and is exchanged

  7. Characterization, Monitoring, and Sensor Technology Integrated Program (CMST-IP)

    International Nuclear Information System (INIS)

    1994-04-01

    The Characterization, Monitoring, and Sensor Technology Integrated Program seeks to deliver needed technologies, timely and cost-effectively, to the Office of Waste Management (EM-30), the Office of Environmental Restoration (EM-40), and the Office of Facility Transition and Management (EM-60). The scope of characterizations monitoring, and sensor technology needs that are required by those organizations encompass: (1) initial location and characterization of wastes and waste environments - prior to treatment; (2) monitoring of waste retrieval, remediation and treatment processes; (3) characterization of the co-position of final waste treatment forms to evaluate the performance of waste treatments processes; and (4) site closure and compliance monitoring. Wherever possible, the CMST-IP fosters technology transfer and commercialization of technologies that it sponsors

  8. Outsourcing the Portal: Another Branch in the Decision Tree.

    Science.gov (United States)

    McMahon, Tim

    2000-01-01

    Discussion of the management of information resources in organizations focuses on the use of portal technologies to update intranet capabilities. Considers application outsourcing decisions, reviews benefits (including reducing costs) as well as concerns, and describes application service providers (ASPs). (LRW)

  9. Regional blood flows by the microsphere method: reproducibility in portal hypertensive rats and influence of a portal vein catheter

    International Nuclear Information System (INIS)

    Hadengue, A.; Lee, S.S.; Koshy, A.; Girod, C.; Lebrec, D.

    1988-01-01

    To determine the reproducibility of splanchnic blood flow measurements by the microsphere method in rats with portal hypertension and the effects of laparotomy with portal vein cannulation, eight groups of 10 rats were studied. Microspheres were labelled with 113 Sn or 141 Ce. Laparotomy with portal cannulation had no significant effect in sham-operated rats. In awake portal hypertensive rats, cardiac output and splanchnic blood flow were lower in portal vein cannulated rats compared with those of non-cannulated animals. In anesthetized portal hypertensive rats blood flows were unaffected by portal cannulation, but arterial pressure and heart rate were elevated. Anesthesia also decreased portal pressure in portal hypertensive rats. We conclude that the microsphere method remains reproducible in portal hypertensive rat models. Laparotomy with portal cannulation can alter systemic and splanchnic hemodynamics in portal hypertensive rats; these effects can also be changed during pentobarbital anesthesia. Regional blood flow measurements in portal hypertensive rats should be performed in animals without portal cannulation and preferably in the awake state

  10. Lab-Based Measurement of Remediation Techniques for Radiation Portal Monitors (Initial Report)

    International Nuclear Information System (INIS)

    Livesay, Jake

    2012-01-01

    Radiation Portal Monitors (RPM) deployed by the Second Line of Defense (SLD) are known to be sensitive to the natural environmental radioactive background. There are several techniques used to mitigate the effects of background on the monitors, but since the installation environments can vary significantly from one another the need for a standardized, systematic, study of remediation techniques was proposed and carried out. This study is not meant to serve as the absolute last word on the subject. The data collected are, however, intelligible and useful. Some compromises were made, each of which will be described in detail. The hope of this initial report is to familiarize the SLD science teams with ORNL's effort to model the effect of various remediation techniques on simple, static backgrounds. This study provides a good start toward benchmarking the model, and each additional increment of data will serve to make the model more robust. The scope of this initial study is limited to a few basic cases. Its purpose is to prove the utility of lab-based study of remediation techniques and serve as a standard data set for future use. This importance of this first step of standardization will become obvious when science teams are working in parallel on issues of remediation; having a common starting point will do away with one category of difference, thereby making easier the task of determining the sources of disagreement. Further measurements will augment this data set, allowing for further constraint of the universe of possible situations. As will be discussed in the 'Going Forward' section, more data will be included in the final report of this work. Of particular interest will be the data taken with the official TSA lead collimators, which will provide more direct results for comparison with installation data.

  11. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    Lattin, Kenneth R.

    1978-01-01

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  12. Development of Distributed System for Informational Location and Control on the Corporate Web Portal "Analytical Chemistry in Russia"

    Science.gov (United States)

    Shirokova, V. I.; Kolotov, V. P.; Alenina, M. V.

    A new Internet portal developed by community of Russian analysts has been launched in 2001 (http://www.geokhi.ru/~rusanalytchem, http://www.rusanalytchem.org) Corporate Web Portal information, "Analytical Chemistry in Russia" , Corporate Web Portal information, "Analytical Chemistry in Russia" ). Now the portal contains a large amount of information, great part of it is stored in the form of SQL data base (MS SQL). The information retrieval is made by means of ASP pages, containing VB Scripts. The obtained experience of work with such topical portal has detected some weak points, related with its centralized administration and updating. It has been found that urgent supporting of all requests from different persons/organizations on information allocation on the portal's server takes a lot of efforts and time. That is why, the further development of portal we relate with development of a distributed system for information allocation and control, under preserving of centralized administration for ensuring of security and stable working of the portal. Analysis and testing of some available technologies lead us to conclusion to apply MS Share Point technologies. A MS Share Point Team Services (SPTS) has been selected as a technology supporting relatively small groups, where MS SQL is used for storage data and metadata. The last feature was considered as decisive one for SPTS selection, allowing easy integration with data base of the whole portal. SPTS was launched as an independent Internet site accessible from home page of the portal. It serves as a root site to exit to dozens of subsites serving different bodies of Russian Scientific Council on analytical chemistry and external organizations located over the whole Russia. The secure functioning of such hierarchical system, which includes a lot of remote information suppliers, based on use of roles to manage user rights independently for each subsite. The root site is controlled by portal administrator, whereas the

  13. Space technology, sustainable development and community applications: Internet as a facilitator

    Science.gov (United States)

    Peter, Nicolas; Afrin, Nadia; Goh, Gérardine; Chester, Ed

    2006-07-01

    Among other approaches, space technologies are currently being deployed for disaster management, environmental monitoring, urban planning, health applications, communications, etc. Although space-based applications have tremendous potential for socioeconomic development, they are primarily technology driven and the requirements from the end-users (i.e. the development community) are rarely taken into consideration during the initial development stages. This communication gap between the "space" and "development" communities can be bridged with the help of the web-based knowledge sharing portal focused on space applications for development. This online community uses the development gateway foundation's sophisticated content management system. It is modeled after the development gateway's knowledge sharing portals ( http://topics.developmentgateway.org) and draws from their expertise in knowledge management, partnership building and marketing. These types of portal are known to facilitate broad-based partnerships across sectors, regions and the various stakeholders but also to facilitate North-South and South-South cooperation. This paper describes the initiative "Space for Development" ( http://topics.developmentgateway.org/space) started in 2004 which aims to demonstrate how such a web-based portal can be structured to facilitate knowledge sharing in order to bridge the gap between the "space" and "development" communities in an innovative and global manner.

  14. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  15. Magnetic Resonance Imaging of a Liver Hydatid Cyst Invading the Portal Vein and Causing Portal Cavernomatosis.

    Science.gov (United States)

    Herek, Duygu; Sungurtekin, Ugur

    2015-01-01

    Hepatic hydatid cysts rarely invade portal veins causing portal cavernomatosis as a secondary complication. We report the case of a patient with direct invasion of the right portal vein by hydatid cysts causing portal cavernomatosis diagnosed via magnetic resonance imaging (MRI). The presented case highlights the useful application of MRI with T2-weighted images and gadolinium-enhanced T1-weighted images in the diagnosis of hepatic hydatid lesions presenting with a rare complication of portal cavernomatosis.

  16. Colangiopatía portal: complicación poco frecuente de la hipertensión portal

    OpenAIRE

    Veloso, Victoria; Servente, Liliana; Hernández, Nelia

    2017-01-01

    Resumen: Se describe el caso clínico de una mujer de 62 años en la que se diagnostica una estenosis del colédoco en el contexto de hipertensión portal prehepática (cavernomatosis portal). Abstract: We report the case of a 62 years old woman with a choledochal stricture and chronic obstruction of the portal vein (portal cavernomatosis). Resumo: Relatamos o caso de uma mulher de 62 anos com diagnóstico de estenose do colédoco no contexto da hipertensão portal pré-hepática (cavernomat...

  17. The XCAT Science Portal

    Directory of Open Access Journals (Sweden)

    Sriram Krishnan

    2002-01-01

    Full Text Available This paper describes the design and prototype implementation of the XCAT Grid Science Portal. The portal lets grid application programmers script complex distributed computations and package these applications with simple interfaces for others to use. Each application is packaged as a notebook which consists of web pages and editable parameterized scripts. The portal is a workstation-based specialized personal web server, capable of executing the application scripts and launching remote grid applications for the user. The portal server can receive event streams published by the application and grid resource information published by Network Weather Service (NWS [35] or Autopilot [16] sensors. Notebooks can be published and stored in web based archives for others to retrieve and modify. The XCAT Grid Science Portal has been tested with various applications, including the distributed simulation of chemical processes in semiconductor manufacturing and collaboratory support for X-ray crystallographers.

  18. Best Practices for Building Web Data Portals

    Science.gov (United States)

    Anderson, R. A.; Drew, L.

    2013-12-01

    technology, SEO rich content and more. As a result, it was on the first page of numerous related Google search results within 24 hours of the portal launch. 8) Build in-browser data analysis tools showing scientists how the data can be used in their research. The ASF DAAC Wetlands portal demonstrates that allowing the user to examine the data quickly and graphically online readily enables users to perceive the value of the data and how to use it. 9) Use responsive Web design (RWD) so content and tools can be accessed from a wide range of devices. Wetlands and Seasat can be accessed from smartphones, tablets and desktops. 10) Use Web frameworks to enable rapid building of new portals using consistent design patterns. Seasat and Wetlands both use Django and Twitter Bootstrap. 11) Use load-balanced servers if high demand for the data is anticipated. Using load-balanced servers for the Seasat and Wetlands portals allows ASF to simply add hardware as needed to support increased capacity. 12) Use open-source software when possible. Seasat and Wetlands portal development costs were reduced, and functionality was increased, with the use of open-source software. 13) Use third-party virtual servers (e.g. Amazon EC2 and S3 Services) where applicable. 14) Track visitors using analytic tools. 15) Continually improve design.

  19. PHL10/460: Cancerfacts.com - Vertical Portal with Newly Developed Health Profiler

    OpenAIRE

    Lenz, C; Brucksch, M

    1999-01-01

    Introduction Unlike general health portals such as WebMD and Drkoop.com that cover everything from the flu to heart disease, Silicon Valley-based cancerfacts.com is a so-called vertical portal. It covers only one small vertical niche of health care: cancer, and in particular, prostate cancer. As a value-added proprietary technology, the company offers its newly developed profile engine to health information retrievers. Methods Users are enabled to insert their specific medical information - r...

  20. The BioMart community portal: an innovative alternative to large, centralized data repositories

    Science.gov (United States)

    Smedley, Damian; Haider, Syed; Durinck, Steffen; Pandini, Luca; Provero, Paolo; Allen, James; Arnaiz, Olivier; Awedh, Mohammad Hamza; Baldock, Richard; Barbiera, Giulia; Bardou, Philippe; Beck, Tim; Blake, Andrew; Bonierbale, Merideth; Brookes, Anthony J.; Bucci, Gabriele; Buetti, Iwan; Burge, Sarah; Cabau, Cédric; Carlson, Joseph W.; Chelala, Claude; Chrysostomou, Charalambos; Cittaro, Davide; Collin, Olivier; Cordova, Raul; Cutts, Rosalind J.; Dassi, Erik; Genova, Alex Di; Djari, Anis; Esposito, Anthony; Estrella, Heather; Eyras, Eduardo; Fernandez-Banet, Julio; Forbes, Simon; Free, Robert C.; Fujisawa, Takatomo; Gadaleta, Emanuela; Garcia-Manteiga, Jose M.; Goodstein, David; Gray, Kristian; Guerra-Assunção, José Afonso; Haggarty, Bernard; Han, Dong-Jin; Han, Byung Woo; Harris, Todd; Harshbarger, Jayson; Hastings, Robert K.; Hayes, Richard D.; Hoede, Claire; Hu, Shen; Hu, Zhi-Liang; Hutchins, Lucie; Kan, Zhengyan; Kawaji, Hideya; Keliet, Aminah; Kerhornou, Arnaud; Kim, Sunghoon; Kinsella, Rhoda; Klopp, Christophe; Kong, Lei; Lawson, Daniel; Lazarevic, Dejan; Lee, Ji-Hyun; Letellier, Thomas; Li, Chuan-Yun; Lio, Pietro; Liu, Chu-Jun; Luo, Jie; Maass, Alejandro; Mariette, Jerome; Maurel, Thomas; Merella, Stefania; Mohamed, Azza Mostafa; Moreews, Francois; Nabihoudine, Ibounyamine; Ndegwa, Nelson; Noirot, Céline; Perez-Llamas, Cristian; Primig, Michael; Quattrone, Alessandro; Quesneville, Hadi; Rambaldi, Davide; Reecy, James; Riba, Michela; Rosanoff, Steven; Saddiq, Amna Ali; Salas, Elisa; Sallou, Olivier; Shepherd, Rebecca; Simon, Reinhard; Sperling, Linda; Spooner, William; Staines, Daniel M.; Steinbach, Delphine; Stone, Kevin; Stupka, Elia; Teague, Jon W.; Dayem Ullah, Abu Z.; Wang, Jun; Ware, Doreen; Wong-Erasmus, Marie; Youens-Clark, Ken; Zadissa, Amonida; Zhang, Shi-Jian; Kasprzyk, Arek

    2015-01-01

    The BioMart Community Portal (www.biomart.org) is a community-driven effort to provide a unified interface to biomedical databases that are distributed worldwide. The portal provides access to numerous database projects supported by 30 scientific organizations. It includes over 800 different biological datasets spanning genomics, proteomics, model organisms, cancer data, ontology information and more. All resources available through the portal are independently administered and funded by their host organizations. The BioMart data federation technology provides a unified interface to all the available data. The latest version of the portal comes with many new databases that have been created by our ever-growing community. It also comes with better support and extensibility for data analysis and visualization tools. A new addition to our toolbox, the enrichment analysis tool is now accessible through graphical and web service interface. The BioMart community portal averages over one million requests per day. Building on this level of service and the wealth of information that has become available, the BioMart Community Portal has introduced a new, more scalable and cheaper alternative to the large data stores maintained by specialized organizations. PMID:25897122

  1. Genomics Portals: integrative web-platform for mining genomics data

    Directory of Open Access Journals (Sweden)

    Ghosh Krishnendu

    2010-01-01

    Full Text Available Abstract Background A large amount of experimental data generated by modern high-throughput technologies is available through various public repositories. Our knowledge about molecular interaction networks, functional biological pathways and transcriptional regulatory modules is rapidly expanding, and is being organized in lists of functionally related genes. Jointly, these two sources of information hold a tremendous potential for gaining new insights into functioning of living systems. Results Genomics Portals platform integrates access to an extensive knowledge base and a large database of human, mouse, and rat genomics data with basic analytical visualization tools. It provides the context for analyzing and interpreting new experimental data and the tool for effective mining of a large number of publicly available genomics datasets stored in the back-end databases. The uniqueness of this platform lies in the volume and the diversity of genomics data that can be accessed and analyzed (gene expression, ChIP-chip, ChIP-seq, epigenomics, computationally predicted binding sites, etc, and the integration with an extensive knowledge base that can be used in such analysis. Conclusion The integrated access to primary genomics data, functional knowledge and analytical tools makes Genomics Portals platform a unique tool for interpreting results of new genomics experiments and for mining the vast amount of data stored in the Genomics Portals backend databases. Genomics Portals can be accessed and used freely at http://GenomicsPortals.org.

  2. Anatomy of the Portal Vein Bifurcation: Implication for Transjugular Intrahepatic Portal Systemic Shunts

    International Nuclear Information System (INIS)

    Kwok, Philip Chong-hei; Ng, Wai Fu; Lam, Christine Suk-yee; Tsui, Polly Po; Faruqi, Asma

    2003-01-01

    Purpose: The relationship of the portalvein bifurcation to the liver capsule in Asians, which is an important landmark for transjugular intrahepatic portosystemic shunt, has not previously been described. Methods: The anatomy of the portal vein bifurcation was studied in 70 adult Chinese cadavers; it was characterized as intrahepatic or extrahepatic. The length of the exposed portion of the right and left portal veins was measured when the bifurcation was extrahepatic. Results: The portal vein bifurcation was intrahepatic in 37 cadavers (53%) and extrahepatic in 33 cadavers (47%). The mean length of the right and left extrahepatic portal veins was 0.96 cm and 0.85 cm respectively.Both were less than or equal to 2 cm in 94% of the cadavers with extrahepatic bifurcation. There was no correlation between the presence of cirrhosis and the location of the portal vein bifurcation(p 1.0). There was no statistically significant difference in liver mass in cadavers with either extrahepatic or intrahepatic bifurcation (p =0.40). Conclusions: These findings suggest that fortransjugular intrahepatic portosystemic shunt placement, a portal vein puncture 2 cm from the bifurcation will be safe in most cases

  3. The application of TIPSS in portal vein cancerous thrombosis complicated with portal hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Zhu Wenke; Liu Lang; Guo Tiansheng

    2002-01-01

    Objective: To discuss the technical skills and the contraindication of trans-jugular intrahepatic portosystemic shunt stent (TIPSS) in portal vein cancerous thrombosis (PVCT) complicated with portal hypertension. Methods: There were 16 cases of PVCT with portal hypertension, and average age of 53.6 yr. There were 9 cases with complete occlusion of portal vein trunk and 7 cases with incomplete thrombosis. There were 5 cases with cavernous transformation of the portal vein (CTPV). 1 case of simple upper gastro-intestinal tract (GIT) massive bleeding, 4 with refractory ascites and 11 with upper GIT massive bleeding and refractory ascites. Results: The procedure of TIPS was successful in 11 cases, the successful rate reached about 68.8%. The mean portal vein pressure was reduced from 4.9 kPa to 2.4 kPa with average 2. 5 kPa reduction. Ascites decreased, bleeding stopped and the clinical symptoms disappeared. The average survival period was 136 days. The procedure failed in 5 cases. Conclusions: TIPSS is an effective method to control the bleeding and ascites caused by PVCT. The PV cavernous transformation was the contraindication of TIPSS

  4. The NOAO NVO Portal

    Science.gov (United States)

    Miller, C. J.; Gasson, D.; Fuentes, E.

    2007-10-01

    The NOAO NVO Portal is a web application for one-stop discovery, analysis, and access to VO-compliant imaging data and services. The current release allows for GUI-based discovery of nearly a half million images from archives such as the NOAO Science Archive, the Hubble Space Telescope WFPC2 and ACS instruments, XMM-Newton, Chandra, and ESO's INT Wide-Field Survey, among others. The NOAO Portal allows users to view image metadata, footprint wire-frames, FITS image previews, and provides one-click access to science quality imaging data throughout the entire sky via the Firefox web browser (i.e., no applet or code to download). Users can stage images from multiple archives at the NOAO NVO Portal for quick and easy bulk downloads. The NOAO NVO Portal also provides simplified and direct access to VO analysis services, such as the WESIX catalog generation service. We highlight the features of the NOAO NVO Portal (http://nvo.noao.edu).

  5. New technologies in nuclear power plant monitoring and diagnosis

    International Nuclear Information System (INIS)

    Tuerkcan, E.; Ciftcioglu, Oe.

    1996-05-01

    The content of the present paper is as follows. In Sec. 2, the Kalman filtering is briefly described and its relevance to conventional time series analysis methods has been emphasized. In this respect, its NPP monitoring and fault diagnosis implementations are given and the important features are pointed out. In Sec. 3, the NN technology is briefly described and the scope is focused on the NPP monitoring and fault diagnosis implementations. The potentialities of this technology are pointed out. In Sec. 4, the wavelet technology is briefly described and the utilization of this technology in Nuclear Technology is demonstrated. In this respect, also the prospective role of this technology for real-time monitoring and fault diagnosis is revealed. Finally, the influence of the new technologies in reliable and cost effective plant operation viewpoint is discussed. (orig./WL)

  6. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  7. Development of XML Schema for Broadband Digital Seismograms and Data Center Portal

    Science.gov (United States)

    Takeuchi, N.; Tsuboi, S.; Ishihara, Y.; Nagao, H.; Yamagishi, Y.; Watanabe, T.; Yanaka, H.; Yamaji, H.

    2008-12-01

    There are a number of data centers around the globe, where the digital broadband seismograms are opened to researchers. Those centers use their own user interfaces and there are no standard to access and retrieve seismograms from different data centers using unified interface. One of the emergent technologies to realize unified user interface for different data centers is the concept of WebService and WebService portal. Here we have developed a prototype of data center portal for digital broadband seismograms. This WebService portal uses WSDL (Web Services Description Language) to accommodate differences among the different data centers. By using the WSDL, alteration and addition of data center user interfaces can be easily managed. This portal, called NINJA Portal, assumes three WebServices: (1) database Query service, (2) Seismic event data request service, and (3) Seismic continuous data request service. Current system supports both station search of database Query service and seismic continuous data request service. Data centers supported by this NINJA portal will be OHP data center in ERI and Pacific21 data center in IFREE/JAMSTEC in the beginning. We have developed metadata standard for seismological data based on QuakeML for parametric data, which has been developed by ETH Zurich, and XML-SEED for waveform data, which was developed by IFREE/JAMSTEC. The prototype of NINJA portal is now released through IFREE web page (http://www.jamstec.go.jp/pacific21/).

  8. Editors' welcome, PORTAL, Vol 6, No 2, July 2009

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2010-01-01

    Full Text Available ‘Post-Mao, Post-Bourdieu: Class and Taste in Contemporary China,’ is a special issue of PORTAL Journal of Multidisciplinary International Studies guest-edited by Yi Zheng (University of Sydney and Stephanie Hemelryk Donald (RMIT University. The special issue explores the relationship between taste, choice and social stratification in contemporary China, and includes a new section, ‘New Perspectives Reports,’ which is intended to showcase opinion and ideas—in this case from the People’s Republic of China, in Mandarin—that complement the main articles. We hope to include this section in future issues of the journal. The guest editors and the PORTAL editorial committee would like to acknowledge that this special issue of is a result of a funding grant from the Australian Research Council, 2003-2005: ‘The Making of Middle-Class Taste: Reading, Tourism, and Educational Choices in Urban China.’ I am also delighted to announce that the PORTAL Editorial Committee has three new members, all from the Faculty of Arts and Social Sciences at the University of Technology, Sydney: Dr Malcolm Angelucci, Dr Beatriz Carrillo, and Dr Fredericka van der Lubbe. Paul Allatson, Editor, PORTAL Journal of Multidisciplinary International Studies.

  9. A Three Tier Architecture Applied to LiDAR Processing and Monitoring

    Directory of Open Access Journals (Sweden)

    Efrat Jaeger-Frank

    2006-01-01

    Full Text Available Emerging Grid technologies enable solving scientific problems that involve large datasets and complex analyses, which in the past were often considered difficult to solve. Coordinating distributed Grid resources and computational processes requires adaptable interfaces and tools that provide modularized and configurable environments for accessing Grid clusters and executing high performance computational tasks. Computationally intensive processes are also subject to a high risk of component failures and thus require close monitoring. In this paper we describe a scientific workflow approach to coordinate various resources via data analysis pipelines. We present a three tier architecture for LiDAR interpolation and analysis, a high performance processing of point intensive datasets, utilizing a portal, a scientific workflow engine and Grid technologies. Our proposed solution is available to the community in a unified framework through a shared cyberinfrastructure, the GEON portal, enabling scientists to focus on their scientific work and not be concerned with the implementation of the underlying infrastructure.

  10. A novel canine model of portal vein stenosis plus thioacetamide administration-induced cirrhotic portal hypertension with hypersplenism.

    Science.gov (United States)

    Lin, Dexin; Wu, Xianbin; Ji, Xiaoke; Zhang, Qiyu; Lin, YuanWei; Chen, WeiJian; Jin, Wangxun; Deng, Liming; Chen, Yunzhi; Chen, Bicheng; Li, Jianmin

    2012-01-01

    Current large animal models that could closely resemble the typical features of cirrhotic portal hypertension in human have not been well established. Thus, we aimed to develop and describe a reliable and reproducible canine cirrhosis model of portal hypertension. A total of 30 mongrel dogs were randomly divided into four groups: 1 (control; n = 5), 2 (portal vein stenosis [PVS]; n = 5], 3 (thioacetamide [TAA]; n = 5), and 4 (PVS plus TAA; n = 15). After 4-months modeling period, liver and spleen CT perfusion, abdominal CT scans, portal hemodynamics, gastroscopy, hepatic function, blood routine, the bone marrow, liver, and spleen histology were studied. The animals in group 2 (PVS) developed extrahepatic portosystemic collateral circulation, particularly esophageal varices, without hepatic cirrhosis and portal hypertension. Animals from group 3 (TAA) presented mild cirrhosis and portal hypertension without significant symptoms of esophageal varices and hypersplenism. In contrast, animals from group 4 (PVS + TAA) showed well-developed micronodular and macronodular cirrhosis, associated with significant portal hypertension and hypersplenism. The combination of PVS and TAA represents a novel, reliable, and reproducible canine cirrhosis model of portal hypertension, which is associated with the typical characteristics of portal hypertension, including hypersplenism.

  11. Personalization Methods for Internet Portals

    OpenAIRE

    Barbara Dębska; Agnieszka Kubacka

    2012-01-01

    The article presents methods of acquiring and gathering data about users of internet portals, with particular emphasis on educational portals. Definitions, aims and tasks related to the process of personalization of e-learning portals are thoroughly discussed. So are knowledge acquisition techniques applied in personalization, especially artificial intelligence methods.

  12. IMPACT web portal: oncology database integrating molecular profiles with actionable therapeutics.

    Science.gov (United States)

    Hintzsche, Jennifer D; Yoo, Minjae; Kim, Jihye; Amato, Carol M; Robinson, William A; Tan, Aik Choon

    2018-04-20

    With the advancement of next generation sequencing technology, researchers are now able to identify important variants and structural changes in DNA and RNA in cancer patient samples. With this information, we can now correlate specific variants and/or structural changes with actionable therapeutics known to inhibit these variants. We introduce the creation of the IMPACT Web Portal, a new online resource that connects molecular profiles of tumors to approved drugs, investigational therapeutics and pharmacogenetics associated drugs. IMPACT Web Portal contains a total of 776 drugs connected to 1326 target genes and 435 target variants, fusion, and copy number alterations. The online IMPACT Web Portal allows users to search for various genetic alterations and connects them to three levels of actionable therapeutics. The results are categorized into 3 levels: Level 1 contains approved drugs separated into two groups; Level 1A contains approved drugs with variant specific information while Level 1B contains approved drugs with gene level information. Level 2 contains drugs currently in oncology clinical trials. Level 3 provides pharmacogenetic associations between approved drugs and genes. IMPACT Web Portal allows for sequencing data to be linked to actionable therapeutics for translational and drug repurposing research. The IMPACT Web Portal online resource allows users to query genes and variants to approved and investigational drugs. We envision that this resource will be a valuable database for personalized medicine and drug repurposing. IMPACT Web Portal is freely available for non-commercial use at http://tanlab.ucdenver.edu/IMPACT .

  13. Adoption and use of a university registration portal by ...

    African Journals Online (AJOL)

    Venkatesh combined eight of the most popular models to formulate a new model, called the Unified Theory of Acceptance and Use of Technology (UTAUT), ... of the model - performance expectancy (PE), effort expectancy (EE) and social influence (SI) – are found to be insignificant determinants of registration portal usage, ...

  14. Applications of aerospace technology in biomedicine. A technology transfer profile: Patient monitoring

    Science.gov (United States)

    Murray, D. M.

    1971-01-01

    NASA contributions to cardiovascular monitoring are described along with innovations in intracardiac blood pressure monitoring. A brief overview of the process of NASA technology transfer in patient monitoring is presented and a list of bioinstrumentation tech briefs and the number of requests for technical support is included.

  15. Impact of health portal enrollment with email reminders on adherence to clinic appointments: a pilot study.

    Science.gov (United States)

    Horvath, Monica; Levy, Janet; L'Engle, Pete; Carlson, Boyd; Ahmad, Asif; Ferranti, Jeffrey

    2011-05-26

    Internet portal technologies that provide access to portions of electronic health records have the potential to revolutionize patients' involvement in their care. However, relatively few descriptions of the demographic characteristics of portal enrollees or of the effects of portal technology on quality outcomes exist. This study examined data from patients who attended one of seven Duke Medicine clinics and who were offered the option of enrolling in and using the Duke Medicine HealthView portal (HVP). The HVP allows patients to manage details of their appointment scheduling and provides automated email appointment reminders in addition to the telephone and mail reminders that all patients receive. Our objective was to test whether portal enrollment with an email reminder functionality is significantly related to decreases in rates of appointment "no-shows," which are known to impair clinic operational efficiency. Appointment activity during a 1-year period was examined for all patients attending one of seven Duke Medicine clinics. Patients were categorized as portal enrollees or as nonusers either by their status at time of appointment or at the end of the 1-year period. Demographic characteristics and no-show rates among these groups were compared. A binomial logistic regression model was constructed to measure the adjusted impact of HVP enrollment on no-show rates, given confounding factors. To demonstrate the effect of HVP use over time, monthly no-show rates were calculated for patient appointment keeping and contrasted between preportal and postportal deployment periods. Across seven clinics, 58,942 patients, 15.7% (9239/58,942) of whom were portal enrollees, scheduled 198,199 appointments with an overall no-show rate of 9.9% (19,668/198,199). We found that HVP enrollees were significantly more likely to be female, white, and privately insured compared with nonusers. Bivariate no-show rate differences between portal enrollment groups varied widely according

  16. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  17. Gamma portal detector with micro-processed and GSM communication system

    International Nuclear Information System (INIS)

    Carneiro, Lindolff Thadeu

    2008-01-01

    Full text: We present in this paper a new concept of gamma radiation portal detector, where the detection process is monitored by a micro-controller, coupled to a compatible GSM communication system, which is suitable to be accessed by all mobile phone operators worldwide. The signal generated at the detectors is converted by an A/D circuit, and driven to a micro-controller where a software evaluates the signal conditions and, depending on a previously set program, it triggers a communication system which sends the alarm to any computer linked to internet and/or to any mobile phone protocol by a specific software linked to the portal. The control electronic system is compatible to several detectors types, ranging from gas based devices to solid state ones. The portal is totally compatible with the ANSI - Standard N42.35 - 2004. It can be used in all types of government and industrial control scenarios. Its measure device permits the use of the equipment in all range of sensibility and in tracking radiation signals where it is. (author)

  18. Usability of Discovery Portals

    OpenAIRE

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals are not spatial data experts but professionals with limited spatial knowledge, and a focus outside the spatial domain. An exploratory usability experiment was carried out in which three discovery p...

  19. Commissioning of Portal Dosimetry and characterization of an EPID; Comissionamento de Portal Dosimetry e caracterizacao de EPID

    Energy Technology Data Exchange (ETDEWEB)

    Olbi, D.S.; Sales, C.P. [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina; Nakandakari, M.V.N., E-mail: diego.olbi@hc.fm.usp.br [Instituto do Cancer do Estado de Sao Paulo, SP (Brazil). Servico de Radioterapia

    2016-07-01

    The development of technologies compensator blocks, MLC, high dose rate accelerators, treatment planning systems, among others, permitted that new treatment techniques in radiotherapy were created. Such techniques have the capacity to modulate radiation beam fluency (IMRT, VMAT), or to deliver high doses in few fractions or unique fractions (SRS). Following the same tendency, quality control of planning became more complex. It is necessary to evaluate the fluency delivered by the accelerator. Its levels of does and its spatial distribution should co-occur with the fluency calculated by TPS. Acquisition of new detector devices in quality control of treatments is fundamental to apply techniques. Portal Vision is a device EPID has the capacity to operate either in image mode or dosimetry mode, with the allowance of Portal Dosimetry. To evaluated planning in IMRT, the device is irradiated using planning e, therefore, the fluency measured is compared with calculated fluency, through gamma analysis. The aim of this work was to perform tests of commissioning of this device. (author)

  20. Duplex sonography in portal hypertension

    International Nuclear Information System (INIS)

    Kwon, Hyuk Po; Jang, J. C.; Park, B. H.

    1990-01-01

    We measure the diameter and blood velocity of the portal vein in 50 patients with cirrhosis of the liver and 40 healthy subjects, and calculated cross sectional area, mean blood flow velocity, blood flow volume and congestion index. In patients with cirrhosis of the liver, the cross sectional area of the portal vein was significantly increased: the mean blood flow volume was significantly reduced; the blood flow volume was significantly increased; the congestion index of the portal vein was significantly increased. Duples sonography may play an important role in the diagnosis of portal hypertension

  1. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    OpenAIRE

    Madhusudhan, KS; Agrawal, Nikhil; Srivastava, Deep N; Pal, Sujoy; Gupta, Arun K

    2013-01-01

    Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, su...

  2. Quantitative vs. subjective portal verification using digital portal images.

    Science.gov (United States)

    Bissett, R; Leszczynski, K; Loose, S; Boyko, S; Dunscombe, P

    1996-01-15

    Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamfer matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 degrees. For all four oncologists, the portals classified

  3. Strategi Branding Portal Online Www.tripriau.com Dalam Membangun Brand Awareness Sebagai Portal Online Pariwisata Provinsi Riau

    OpenAIRE

    Rahmadhani, Yuri; Lubis, Evawani Elysa

    2017-01-01

    Online portal www.tripriau.com online portal is one of the online portal in Riau Province that has its own uniqueness. These portals contain local content and the potential of tourism in the province of Riau. Since its establishment, www.tripriau.com do branding strategy in order to build brand awareness or trust the reader to be known as a tourism-themed online portal. As the selection of brand name Trip Riau, Riau Guide My tagline, as well as the implementation of travel instagram photo con...

  4. The Sydney West Knowledge Portal: Evaluating the Growth of a Knowledge Portal to Support Translational Research.

    Science.gov (United States)

    Janssen, Anna; Robinson, Tracy Elizabeth; Provan, Pamela; Shaw, Tim

    2016-06-29

    The Sydney West Translational Cancer Research Centre is an organization funded to build capacity for translational research in cancer. Translational research is essential for ensuring the integration of best available evidence into practice and for improving patient outcomes. However, there is a low level of awareness regarding what it is and how to conduct it optimally. One solution to addressing this gap is the design and deployment of web-based knowledge portals to disseminate new knowledge and engage with and connect dispersed networks of researchers. A knowledge portal is an web-based platform for increasing knowledge dissemination and management in a specialized area. To measure the design and growth of an web-based knowledge portal for increasing individual awareness of translational research and to build organizational capacity for the delivery of translational research projects in cancer. An adaptive methodology was used to capture the design and growth of an web-based knowledge portal in cancer. This involved stakeholder consultations to inform initial design of the portal. Once the portal was live, site analytics were reviewed to evaluate member usage of the portal and to measure growth in membership. Knowledge portal membership grew consistently for the first 18 months after deployment, before leveling out. Analysis of site metrics revealed members were most likely to visit portal pages with community-generated content, particularly pages with a focus on translational research. This was closely followed by pages that disseminated educational material about translational research. Preliminary data from this study suggest that knowledge portals may be beneficial tools for translating new evidence and fostering an environment of communication and collaboration.

  5. Embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy

    International Nuclear Information System (INIS)

    Sakurabayashi, Shin; Sezai, Shuichi; Yamamoto, Yoshihiro; Hirano, Masanori; Oka, Hiroshi

    1997-01-01

    Purpose. To evaluate the efficacy of embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy (CRHE). Methods. Seven cirrhotic patients with CRHE refractory to medical treatment (3 men and 4 women, mean age 66 years) were studied. Five patients had splenorenal shunts, 1 had a gastrorenal shunt, and 1 had an intrahepatic portal vein-hepatic vein shunt. Shunt embolization was performed using stainless steel coils, with a percutaneous transhepatic portal vein approach in 4 patients and a transrenal vein approach in 3 patients. Results. After embolization, the shunt disappeared in 4 patients on either ultrasound pulsed Doppler monitoring or portography. Complications observed in the 7 patients were fever, transient pleural effusion, ascites, and mild esophageal varices. For 3-6 months after embolization, the 4 patients whose shunts disappeared showed minimal or no reappearance of a shunt, and had no recurrence of encephalopathy. The serum ammonia levels decreased and electroencephalograms also improved. One of the 4 patients, who developed mild esophageal varices, required no treatment. Treatment was effective in 3 of the 4 patients (75%) who underwent embolization via a transhepatic portal vein. Conclusion. Transvascular embolization of shunts improved the outcome in 4 of 7 patients. The most effective embolization was achieved via the percutaneous transhepatic portal vein approach

  6. Palliative treatment of TIPS to portal vein tumor thrombosis complicated with portal vein hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Guo Tiansheng; Liu Lang

    2002-01-01

    Objective: To evaluate the palliative therapeutic effects of transjugular intrahepatic portosystemic shunt (TIPS) in portal vein tumor thrombosis (PVTT) complicated with portal vein hypertension, and to discuss the technical skills. Methods: There were 14 cases of end-stage hepatocellular carcinoma complicated with PVTT and portal vein hypertension, the average age was 53.6 yr. There were 8 cases with complete occlusion of main portal vein, 6 eases with incomplete thrombosis, and 5 cases combined with portal vein cavernous transformation. One case had simple hemorrhage, 3 eases had intractable ascites, and 10 cases had hemorrhage accompanied by intractable ascites. Results: The procedure of TIPS was successful in 10 cases, the successful rate was about 71%. The mean portal vein pressure was reduced from 37.2 mm Hg to 18.2 mm Hg, with an average reduction of 19.0 mm Hg. After the procedure of TIPS, the ascites decreased, hemorrhage stopped and the clinical symptoms disappeared. The average survival period was 132.3 days. The procedure were failing in 4 cases. Conclusion: TIPS was an effective palliative therapeutic methods to control the hemorrhage and ascites aroused by hepatic carcinoma complicated with PVTT

  7. Barriers and Facilitators to Online Portal Use Among Patients and Caregivers in a Safety Net Health Care System: A Qualitative Study.

    Science.gov (United States)

    Tieu, Lina; Sarkar, Urmimala; Schillinger, Dean; Ralston, James D; Ratanawongsa, Neda; Pasick, Rena; Lyles, Courtney R

    2015-12-03

    Patient portals have the potential to support self-management for chronic diseases and improve health outcomes. With the rapid rise in adoption of patient portals spurred by meaningful use incentives among safety net health systems (a health system or hospital providing a significant level of care to low-income, uninsured, and vulnerable populations), it is important to understand the readiness and willingness of patients and caregivers in safety net settings to access their personal health records online. To explore patient and caregiver perspectives on online patient portal use before its implementation at San Francisco General Hospital, a safety net hospital. We conducted 16 in-depth interviews with chronic disease patients and caregivers who expressed interest in using the Internet to manage their health. Discussions focused on health care experiences, technology use, and interest in using an online portal to manage health tasks. We used open coding to categorize all the barriers and facilitators to portal use, followed by a second round of coding that compared the categories to previously published findings. In secondary analyses, we also examined specific barriers among 2 subgroups: those with limited health literacy and caregivers. We interviewed 11 patients and 5 caregivers. Patients were predominantly male (82%, 9/11) and African American (45%, 5/11). All patients had been diagnosed with diabetes and the majority had limited health literacy (73%, 8/11). The majority of caregivers were female (80%, 4/5), African American (60%, 3/5), caregivers of individuals with diabetes (60%, 3/5), and had adequate health literacy (60%, 3/5). A total of 88% (14/16) of participants reported interest in using the portal after viewing a prototype. Major perceived barriers included security concerns, lack of technical skills/interest, and preference for in-person communication. Facilitators to portal use included convenience, health monitoring, and improvements in patient

  8. Characterization, monitoring, and sensor technology catalogue

    International Nuclear Information System (INIS)

    Matalucci, R.V.; Esparza-Baca, C.; Jimenez, R.D.

    1995-12-01

    This document represents a summary of 58 technologies that are being developed by the Department of Energy's (DOE's) Office of Science and Technology (OST) to provide site, waste, and process characterization and monitoring solutions to the DOE weapons complex. The information was compiled to provide performance data on OST-developed technologies to scientists and engineers responsible for preparing Remedial Investigation/Feasibility Studies (RI/FSs) and preparing plans and compliance documents for DOE cleanup and waste management programs. The information may also be used to identify opportunities for partnering and commercialization with industry, DOE laboratories, other federal and state agencies, and the academic community. Each technology is featured in a format that provides: (1) a description, (2) technical performance data, (3) applicability, (4) development status, (5) regulatory considerations, (6) potential commercial applications, (7) intellectual property, and (8) points-of-contact. Technologies are categorized into the following areas: (1) Bioremediation Monitoring, (2) Decontamination and Decommissioning, (3) Field Analytical Laboratories, (4) Geophysical and Hydrologic Characterization, (5) Hazardous Inorganic Contaminant Analysis, (6) Hazardous Organic Contaminant Analysis, (7) Mixed Waste, (8) Radioactive Contaminant Analysis, (9) Remote Sensing,(10)Sampling and Drilling, (11) Statistically Guided Sampling, and (12) Tank Waste

  9. Characterization, monitoring, and sensor technology catalogue

    Energy Technology Data Exchange (ETDEWEB)

    Matalucci, R.V. [ed.] [Sandia National Labs., Albuquerque, NM (United States); Esparza-Baca, C.; Jimenez, R.D. [Applied Sciences Laboratory, Inc., Albuquerque, NM (United States)

    1995-12-01

    This document represents a summary of 58 technologies that are being developed by the Department of Energy`s (DOE`s) Office of Science and Technology (OST) to provide site, waste, and process characterization and monitoring solutions to the DOE weapons complex. The information was compiled to provide performance data on OST-developed technologies to scientists and engineers responsible for preparing Remedial Investigation/Feasibility Studies (RI/FSs) and preparing plans and compliance documents for DOE cleanup and waste management programs. The information may also be used to identify opportunities for partnering and commercialization with industry, DOE laboratories, other federal and state agencies, and the academic community. Each technology is featured in a format that provides: (1) a description, (2) technical performance data, (3) applicability, (4) development status, (5) regulatory considerations, (6) potential commercial applications, (7) intellectual property, and (8) points-of-contact. Technologies are categorized into the following areas: (1) Bioremediation Monitoring, (2) Decontamination and Decommissioning, (3) Field Analytical Laboratories, (4) Geophysical and Hydrologic Characterization, (5) Hazardous Inorganic Contaminant Analysis, (6) Hazardous Organic Contaminant Analysis, (7) Mixed Waste, (8) Radioactive Contaminant Analysis, (9) Remote Sensing,(10)Sampling and Drilling, (11) Statistically Guided Sampling, and (12) Tank Waste.

  10. Portal pressure correlated to visceral circulation times

    Energy Technology Data Exchange (ETDEWEB)

    Friman, L [Serafimerlasarettet, Stockholm (Sweden)

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system.

  11. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    Directory of Open Access Journals (Sweden)

    KS Madhusudhan

    2013-01-01

    Full Text Available Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, successfully treated by self-expandable metallic stent.

  12. Application of a pedestrian portal monitor at Madrid International Airport in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Pujol, Ll., E-mail: luis.pujol@cedex.e [Centro de Estudios y Experimentacion de Obras Publicas (CEDEX), Alfonso XII, 3, 28014 Madrid (Spain); Univ Politecn Madrid (UPM), Dept Civil Engn Hydraul and Energet, ETSI Caminos, Profesor Aranguren, s/n, 28040 Madrid (Spain); Gonzalez-Gonzalez, J.A.; Suarez-Navarro, M.J. [Univ Politecn Madrid (UPM), Dept Civil Engn Hydraul and Energet, ETSI Caminos, Profesor Aranguren, s/n, 28040 Madrid (Spain)

    2011-04-15

    Three pedestrian portal monitor systems, designed to detect illicit trafficking or inadvertent movement of radioactive materials carried by passengers at airports, have been evaluated. The systems were supplied by three manufacturers: Bicron, Exploranium and Thermo-Eberline. In an initial evaluation, conducted at the Laboratory of Nuclear Engineering of the School of Civil Engineering, it was observed that the FHT-1372 system manufactured by Thermo-Eberline gave a more sensitive response and allowed the measurement of total photon dose rate and artificial photon dose rate. Therefore, this system was installed at Barajas International Airport in Madrid in 2002 for a period of 108 days in order to select an appropriate investigation level (defined as the radiation level that is selected as the trigger for further investigation). During this period 1,339,931 passengers were screened and a total of 39 alarms were triggered, 5 of which with a value 10 times the mean value of the natural background from photon radiation (which was 85 nSv/h), and no alarms exceeded 100 {mu}Sv/h at 1 m distance, which is the level of response for legal transport of radioactive materials set by the International Atomic Energy Agency (IAEA). An investigation level of approximately 1.3 times the natural background was finally selected. This value coincides with the results obtained in the ITRAP (Illicit Trafficking Radiation Detection Assessment Program) carried out by the IAEA.

  13. OneGeology Web Services and Portal as a global geological SDI - latest standards and technology

    Science.gov (United States)

    Duffy, Tim; Tellez-Arenas, Agnes

    2014-05-01

    The global coverage of OneGeology Web Services (www.onegeology.org and portal.onegeology.org) achieved since 2007 from the 120 participating geological surveys will be reviewed and issues arising discussed. Recent enhancements to the OneGeology Web Services capabilities will be covered including new up to 5 star service accreditation scheme utilising the ISO/OGC Web Mapping Service standard version 1.3, core ISO 19115 metadata additions and Version 2.0 Web Feature Services (WFS) serving the new IUGS-CGI GeoSciML V3.2 geological web data exchange language standard (http://www.geosciml.org/) with its associated 30+ IUGS-CGI available vocabularies (http://resource.geosciml.org/ and http://srvgeosciml.brgm.fr/eXist2010/brgm/client.html). Use of the CGI simpelithology and timescale dictionaries now allow those who wish to do so to offer data harmonisation to query their GeoSciML 3.2 based Web Feature Services and their GeoSciML_Portrayal V2.0.1 (http://www.geosciml.org/) Web Map Services in the OneGeology portal (http://portal.onegeology.org). Contributing to OneGeology involves offering to serve ideally 1:1000,000 scale geological data (in practice any scale now is warmly welcomed) as an OGC (Open Geospatial Consortium) standard based WMS (Web Mapping Service) service from an available WWW server. This may either be hosted within the Geological Survey or a neighbouring, regional or elsewhere institution that offers to serve that data for them i.e. offers to help technically by providing the web serving IT infrastructure as a 'buddy'. OneGeology is a standards focussed Spatial Data Infrastructure (SDI) and works to ensure that these standards work together and it is now possible for European Geological Surveys to register their INSPIRE web services within the OneGeology SDI (e.g. see http://www.geosciml.org/geosciml/3.2/documentation/cookbook/INSPIRE_GeoSciML_Cookbook%20_1.0.pdf). The Onegeology portal (http://portal.onegeology.org) is the first port of call for anyone

  14. Development of a Web Portal for Physical Activity and Symptom Tracking in Oncology Patients: Protocol for a Prospective Cohort Study.

    Science.gov (United States)

    Marthick, Michael; Dhillon, Haryana M; Alison, Jennifer A; Cheema, Birinder S; Shaw, Tim

    2018-05-15

    Significant benefits accrue from increasing physical activity levels in people with a history of cancer. Physical activity levels can be increased using behavioral change interventions in this population. Access to Web portals and provision of activity monitors to provide feedback may support behavior change by encouraging patient engagement in physical therapy. The Web portal evaluated in this study will provide a system to monitor physical activity and sleep, for use by both clinician and patient, along with symptom and health-related quality of life tracking capabilities. The aim of this study was to outline a protocol for a feasibility study focused on a Web-based portal that provides activity monitoring and personalized messaging to increase physical activity in people with cancer. Using a longitudinal cohort design, people with cancer will be serially allocated to 3 intervention cohorts of 20 participants each and followed for 10 weeks. Cohort 1 will be provided a wearable activity monitor and access to a Web-based portal. Cohort 2 will receive the same content as Cohort 1 and in addition will receive a weekly activity summary message. Cohort 3 will receive the same content as Cohorts 1 and 2 and in addition will receive a personalized weekly coaching message. Feasibility of the use of the portal is the primary outcome. Results are expected in early 2018. Outcome measures will include goal attainment and completion rate. This study will provide information about the feasibility of investigating eHealth initiatives to promote physical activity in people with cancer. RR1-10.2196/9586. ©Michael Marthick, Haryana M Dhillon, Jennifer A Alison, Birinder S Cheema, Tim Shaw. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 15.05.2018.

  15. Portal pressure correlated to visceral circulation times

    International Nuclear Information System (INIS)

    Friman, L.

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system. (Auth.)

  16. Exporting automatic vehicle SNM monitoring technology

    International Nuclear Information System (INIS)

    York, R.L.; Fehlau, P.E.; Close, D.A.

    1995-01-01

    Controlling the transportation of nuclear materials is still one of the most effective nuclear proliferation barriers. The recent increase of global nuclear material proliferation has expanded the application of vehicle monitor technology to prevent the diversion of special nuclear material across international borders. To satisfy this new application, a high-sensitivity vehicle monitor, which is easy to install and capable of operating in high-traffic areas, is required. A study of a new detector configuration for a drive-through vehicle monitor is discussed in this paper

  17. Project Portal User-Centered Design and Engineering Report

    Science.gov (United States)

    2016-06-01

    TECHNICAL REPORT 3013 June 2016 Project Portal User-Centered Design and Engineering Report Deborah Gill-Hesselgrave Veronica Higgins Sarah...Design and Engineering Branch Under authority of Chris Raney, Head Command and Control Technology and Experiments Division iii EXECUTIVE...navy.mil  Christian Szatkowski christian.szatkowski@navy.mil  Roni Higgins roni.higgins@navy.mil  Jake Viraldo jacob.viraldo@navy.mil B

  18. Transjugular intrahepatic portosystemic shunt in patients with active variceal bleeding due to portal hypertension and portal vein thrombosis

    International Nuclear Information System (INIS)

    Shin, Hyun Woong; Ryeom, Hun Kyu; Lee, Sang Kwon; Lee, Jong Min; Kim, Young Sun; Suh, Kyung Jin; Kim, Tae Hun; Kim, Yong Joo

    1997-01-01

    To evaluate the feasibility and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) in patients with active variceal bleeding due to liver cirrhosis and pre-existing portal vein thrombosis. Of a total of 123 patients who underwent TIPS, 14 patients with intractable variceal bleeding due to portal hypertension and portal vein thrombosis were included in this study. Noncavernomatous portal vein occlusion was seen in eight patients, and complete portal vein occlusion with cavernomatous trans-formation in six. For all patients, the methods used for TIPS placement were the same as those used in patients with patents portal veins. In seven of eight patients with noncavernomatous occlusion, right hepatic vein-right portal vein shunting was performed; in one with knoncavernomatous occlusion, a shunt was created between the right hepatic and left portal vein. In five of six patients with cavernomatous occlusion, the right hepatic and main portal vein were connected via a collateral vein. The procedures were technically successful in all except one patient. Immediate hemostatis was achieved after all technically successful procedures, and no significant complications were encountered. Minor complications were noted in six patients (three biliary tree punctures, one transperitoneal puncture, one splenic vein perforation, one hepatic subcapsular hematoma). TIPS is a technically feasible and hemodynamically effective procedure, even in patients with active variceal bleeding due to cirrhosis and complete portal vein occlusion

  19. A chess web portal

    OpenAIRE

    Volf, Žiga

    2011-01-01

    The aim of the thesis was to develop a web portal for chess players, which is intended to be a place for quality chess joining over the Internet and chess education. This need is caused by existing social networks and websites for playing chess, which offer you a very small amount of quality chess joining and education. As a result of the work the chess portal was created. We have presented the development of the chess portal in the thesis, which has all the features the chess players are i...

  20. BSD Portals for LINUX 2.0

    Science.gov (United States)

    McNab, A. David; woo, Alex (Technical Monitor)

    1999-01-01

    Portals, an experimental feature of 4.4BSD, extend the file system name space by exporting certain open () requests to a user-space daemon. A portal daemon is mounted into the file name space as if it were a standard file system. When the kernel resolves a pathname and encounters a portal mount point, the remainder of the path is passed to the portal daemon. Depending on the portal "pathname" and the daemon's configuration, some type of open (2) is performed. The resulting file descriptor is passed back to the kernel which eventually returns it to the user, to whom it appears that a "normal" open has occurred. A proxy portalfs file system is responsible for kernel interaction with the daemon. The overall effect is that the portal daemon performs an open (2) on behalf of the kernel, possibly hiding substantial complexity from the calling process. One particularly useful application is implementing a connection service that allows simple scripts to open network sockets. This paper describes the implementation of portals for LINUX 2.0.

  1. Predictive model of portal venous system thrombosis in cirrhotic portal hypertensive patients after splenectomy

    OpenAIRE

    He, Shasha; He, Fangping

    2015-01-01

    Objective: This study is to investigate the risk factors of portal venous system thrombosis (PVT) in patients with cirrhotic portal hypertension after splenectomy and to establish a Logistic regression prediction model. Methods: A total of 119 patients with cirrhotic portal hypertension were enrolled. Their clinical data was retrospectively analyzed. They were divided into PVT group (n = 18) and non-PVT group (n = 101). One-way analysis and multivariate Logistic regression analysis were perfo...

  2. Quantitative vs. subjective portal verification using digital portal images

    International Nuclear Information System (INIS)

    Bissett, Randy; Leszczynski, Konrad; Loose, Stephen; Boyko, Susan; Dunscombe, Peter

    1996-01-01

    Purpose: Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Methods and Materials: Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamber matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. Results: All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 deg. . For all

  3. Decision Support System for Condition Monitoring Technologies

    NARCIS (Netherlands)

    Mouatamir, Abderrahim

    2018-01-01

    The technological feasibility of a condition-based maintenance (CBM) policy is intrinsically related to the suitable selection of condition monitoring (CM) technologies such as vibration- and oil analysis or other non-destructive testing (NDT) techniques such as radiographic- and magnetic particle

  4. Periodic quality control of a linear accelerator using electronic portal imaging; Controles de calidad periodicos de un acelerador lineal utilizando el sistema electronico de imagenes portales

    Energy Technology Data Exchange (ETDEWEB)

    Planes Meseguer, D.; Dorado Rodriguez, M. P.; Esposito, R. D.

    2011-07-01

    In this paper we present our solution for the realization of the monthly periodic quality control (CP) geometry - mechanical and multi leaf collimator (MLC), using the electronic system for portal imaging (EPI). We have developed specific programs created with free software. The monitoring results are automatically stored on our web server, along with other information generated in our service.

  5. Percutaneous angioplasty of portal vein stenosis that complicated liver transplantation: the mid-term therapeutic results

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Bo; Choo, Sung Wook; Do, Young Soo; Shin, Sung Wook; Cho, Sung Gi; Choo, In Wook [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2005-09-15

    We wanted to valuate the mid-term therapeutic results of percutaneous transhepatic balloon angioplasty for portal vein stenosis after liver transplantation. From May 1996 to Feb 2005, 420 patients underwent liver transplantation. Percutaneous transhepatic angioplasty of the portal vein was attempted in six patients. The patients presented with the clinical signs and symptoms of portal venous hypertension or they were identified by surveillance doppler ultrasonography. The preangioplasty and postangioplasty pressure gradients were recorded. The therapeutic results were monitored by the follow up of the clinical symptoms, the laboratory values, CT and ultrasonography. The overall technical success rate was 100%. The clinical success rate was 83% (5/6). A total of eight sessions of balloon angioplasty were performed in six patients. The mean pressure gradient decreased from 14.5 mmHg to 2.8 mmHg before and after treatment, respectively. The follow up periods ranged from three months to 64 months (mean period; 32 months). Portal venous patency was maintained in all six patients until the final follow up. Combined hepatic venous stenosis was seen in one patient who was treated with stent placement. One patient showed puncture tract bleeding, and this patient was treated with coil embolization of the right portal puncture tract via the left transhepatic portal venous approach. Percutaneous transhepatic balloon angioplasty is an effective treatment for the portal vein stenosis that occurs after liver transplantation, and our results showed good mid-term patency with using this technique.

  6. Development of a New Analysis Tool for Evaluating and Correcting for Weather Conditions that Constrain Radiation Portal Monitor Performance

    International Nuclear Information System (INIS)

    Guzzardo, T.; Livesay, J.

    2011-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) developed the Adaptable, Multiplatform, Real-Time Analysis Package (AMRAP) for the continuous measurement of environmental radionuclide decay. AMRAP is a completely open source visualization and analysis package capable of combining a variety of data streams into an array of real-time plots. Once acquired, data streams are analyzed to store static images and extract data based on previously defined thresholds. AMRAP is currently used at ORNL to combine data streams from an Ortec Detective high-purity germanium (HPGe) detector, a TSA Systems radiation portal monitor (RPM), and an Orion weather station. The combined data are used to study the rain-induced increase in RPM background radiation levels. RPMs experience an increase in background radiation during precipitation due to the deposition of atmospheric radionuclides on the ground. Using AMRAP results in a real-time analysis workstation specifically dedicated to the study of RPM background radiation levels. By means of an editable library of common inputs, AMRAP is adaptable to remote monitoring applications that would benefit from the real-time visualization and analysis of radiation measurements. To study rain-induced increases in background radiation levels observed in radiation portal monitors (RPMs), researchers at Oak Ridge National Laboratory (ORNL) developed a software package that allows data with different formats to be analyzed and plotted in near real time. The Adaptable, Multiplatform, Real-Time Analysis Package (AMRAP) was developed to operate in the background and capture plots of important data based on previously defined thresholds. After executing AMRAP, segments of a data stream can be captured without additional post-processing. AMRAP can also display previously recorded data to facilitate a detailed offline analysis. Without access to these capabilities in a single software package, analyzing multiple continuously recorded data streams with

  7. An automated portal verification system for the tangential breast portal field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Lai, W.; Chen, C. W.; Nelson, D. F.

    1995-01-01

    Purpose/Objective: In order to ensure the treatment is delivered as planned, a portal image is acquired in the accelerator and is compared to the reference image. At present, this comparison is performed by radiation oncologists based on the manually-identified features, which is both time-consuming and potentially error-prone. With the introduction of various electronic portal imaging devices, real-time patient positioning correction is becoming clinically feasible to replace time-delayed analysis using films. However, this procedure requires present of radiation oncologists during patient treatment which is not cost-effective and practically not realistic. Therefore, the efficiency and quality of radiation therapy could be substantially improved if this procedure can be automated. The purpose of this study is to develop a fully computerized verification system for the radiation therapy of breast cancer for which a similar treatment setup is generally employed. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature correlation between reference and portal images, and quantitative evaluation of patient setup. In this study, a matrix liquid ion-chamber EPID was used to acquire digital portal images which is directly attached to Varian CL2100C accelerator. For effective use of computation memory, the 12-bit gray levels in original portal images were quantized to form a range of 8-bit gray levels. A typical breast portal image includes three important components: breast and lung tissues in the treatment field, air space within the treatment field, and non-irradiated region. A hierarchical region processing technique was developed to separate these regions sequentially. The inherent hierarchical features were formulated based on different radiation attenuation for different regions as: treatment field edge -- breast skin line -- chest wall. Initially, a combination of a Canny edge detector and a constrained

  8. Technology review: prototyping platforms for monitoring ambient conditions.

    Science.gov (United States)

    Afolaranmi, Samuel Olaiya; Ramis Ferrer, Borja; Martinez Lastra, Jose Luis

    2018-05-08

    The monitoring of ambient conditions in indoor spaces is very essential owing to the amount of time spent indoors. Specifically, the monitoring of air quality is significant because contaminated air affects the health, comfort and productivity of occupants. This research work presents a technology review of prototyping platforms for monitoring ambient conditions in indoor spaces. It involves the research on sensors (for CO 2 , air quality and ambient conditions), IoT platforms, and novel and commercial prototyping platforms. The ultimate objective of this review is to enable the easy identification, selection and utilisation of the technologies best suited for monitoring ambient conditions in indoor spaces. Following the review, it is recommended to use metal oxide sensors, optical sensors and electrochemical sensors for IAQ monitoring (including NDIR sensors for CO 2 monitoring), Raspberry Pi for data processing, ZigBee and Wi-Fi for data communication, and ThingSpeak IoT platform for data storage, analysis and visualisation.

  9. Application of Video Recognition Technology in Landslide Monitoring System

    Directory of Open Access Journals (Sweden)

    Qingjia Meng

    2018-01-01

    Full Text Available The video recognition technology is applied to the landslide emergency remote monitoring system. The trajectories of the landslide are identified by this system in this paper. The system of geological disaster monitoring is applied synthetically to realize the analysis of landslide monitoring data and the combination of video recognition technology. Landslide video monitoring system will video image information, time point, network signal strength, power supply through the 4G network transmission to the server. The data is comprehensively analysed though the remote man-machine interface to conduct to achieve the threshold or manual control to determine the front-end video surveillance system. The system is used to identify the target landslide video for intelligent identification. The algorithm is embedded in the intelligent analysis module, and the video frame is identified, detected, analysed, filtered, and morphological treatment. The algorithm based on artificial intelligence and pattern recognition is used to mark the target landslide in the video screen and confirm whether the landslide is normal. The landslide video monitoring system realizes the remote monitoring and control of the mobile side, and provides a quick and easy monitoring technology.

  10. INVASIVE AND NON-INVASIVE TECHNIQUES FOR DETECTING PORTAL HYPERTENSION AND PREDICTING VARICEAL BLEEDING IN CIRRHOSIS: A REVIEW

    Science.gov (United States)

    Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J

    2016-01-01

    Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal and post-sinusoidal causes. As a consequence, several complications (i.e., ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from nonbleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques. PMID:24328372

  11. Congestive index of portal vein

    International Nuclear Information System (INIS)

    Kim, Won Ho; Kim, H. K.; Lee, S. C.; Han, S. H.; Han, K. H.; Chung, J. B.; Choi, H. J.

    1989-01-01

    In patients with portal hypertension, the blood flow volume is maintained despite decreased blood flow velocity due to enlargement of the vascular cross sectional area. Thus, the 'congestion index' of the portal vein, which is the ratio between the cross sectional area (cm2) and the blood flow velocity (cm/sec) determined by a Doppler ultrasonography, may be a sensitive index by which to assess portal hypertension. We performed Doppler ultrasonography on 24 normal subjects, 14 patients with biopsy proved chronic active hepatitis and 55 patients with liver cirrhosis in order to assess the diagnostic value of the congestion index. The cross sectional area of the portal vein was significantly enlarged and the mean blood flow velocity was significantly reduced in patients with liver cirrhosis compared with controls. However, the blood flow volume was no difference. The congestion index of the portal vein was significantly increased in patients with liver cirrhosis (0.113+0.035) compared with patients with chronic active hepatitis(0.078+0.029) (p<0.001) and controls (0.053+0.016) (p<0.001). The sensitivity, specificity and predictability of the congestion index for detection of patients with the cirrhosis of the liver were 76.4%, 100% and 100% respectively, when the normal range was set at mean+2SD. The results suggest that the congestion index of the portal vein may pla a significant role in diagnosis of portal hypertensive patients

  12. Measurement and monitoring technologies are important SITE program component

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    An ongoing component of the Superfund Innovative Technologies Evaluation (SITE) Program, managed by the US EPA at its Hazardous Waste Engineering Research Laboratory in Cincinnati, is the development and demonstration of new and innovative measurement and monitoring technologies that will be applicable to Superfund site characterization. There are four important roles for monitoring and measurement technologies at Superfund sites: (1) to assess the extent of contamination at a site, (2) to supply data and information to determine impacts to human health and the environment, (3) to supply data to select the appropriate remedial action, and (4) to monitor the success or effectiveness of the selected remedy. The Environmental Monitoring Systems Laboratory in Las Vegas, Nevada (EMSL-LV) has been supporting the development of improved measurement and monitoring techniques in conjunction with the SITE Program with a focus on two areas: Immunoassay for toxic substances and fiber optic sensing for in-situ analysis at Superfund sites

  13. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  14. Systemic thrombolysis of portal vein thrombosis in cirrhotic patients: a pilot study.

    Science.gov (United States)

    De Santis, Adriano; Moscatelli, Rosanna; Catalano, Carlo; Iannetti, Antonio; Gigliotti, Francesca; Cristofari, Francesca; Trapani, Silvia; Attili, Adolfo F

    2010-06-01

    Portal vein thrombosis is a frequent complication in liver cirrhosis. Encouraging reports of systemic thrombolysis in non-cirrhotic patients suffering from acute portal vein thrombosis led us to start a pilot study on the efficacy and safety of systemic low dose recombinant tissue plasminogen activator (Actilyse, Boheringer Ingelheim, Florence, Italy). Nine cirrhotic patients (6 males and 3 females) with recent portal vein thrombosis were enrolled. Exclusion criteria were portal cavernomatosis, recent (30 days) surgery, active bleeding, hepatocellular carcinoma and cancer in other sites. All cases were treated for a maximum of 7 days by continuous i.v. infusion of 0.25mg/kg/die of r-tPA plus subcutaneous low molecular weight heparin. Efficacy was evaluated by colour doppler sonography monitoring and confirmed by contrast enhanced computerized tomography. The combined r-tPA/LMWH treatment was well tolerated without clinically significant side effects. Complete resolution of thrombosis occurred in 4 cases, partial regression in 4 and none in 1. Retreatment of a complete recurrence in 1 patient was successful. Variceal pressure dropped from 30.7+/-4.5 mmHg to 21.2+/-6.6 mmHg (p=0.012). Our preliminary data demonstrate that thrombolytic treatment of recent portal vein thrombosis with i.v. r-tPA and LMWH in patients with cirrhosis appears to be safe and effective and can significantly reduce pressure in oesophageal varices. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  15. Editor's welcome, PORTAL, Vol. 1, No. 2, July 2004

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2005-03-01

    Full Text Available Since the highly successful inauguration of PORTAL in January 2004, we have received many kind expressions of support from international studies practitioners in a range of fields, and from such places as Canada, Italy, Mexico, Nigeria, New Zealand, Spain, Trinidad, the U.K., and the U.S.A. Particularly gratifying have been the endorsements of the journal and its publishing aims by people involved in their own electronic publishing enterprises. For their generous responses to PORTAL, the Editorial Committee would like to express its collective appreciation to the following people: Professor Jean-Marie Volet, of the University of Western Australia, and the guiding editor of the ground-breaking e-journal Mots Pluriels (www.arts.uwa.edu.au/MotsPluriels; and Francis Leo Collins, member of the Editorial Committee for the Graduate Journal of Asia Pacific Studies (GJAPS, based in Auckland, New Zealand. PORTAL's readers may be interested in the current call for papers from GJAPS (www.arts.auckland.ac.nz/gjaps, for a special issue on "Imagining the Asia-Pacific" (deadline October 31, 2004. This issue of PORTAL contains essays that cover wide terrain: the Chilean diasporic community in Australia; the world of German intellectuals; contemporary Mexican socio-political movements; rural-urban migration in China; and transnational advocacy networks and election monitoring in the Philippines, Chile, Nicaragua and Mexico. In the cultural section of this issue, we are delighted to present a short story from the noted German Studies scholar Anthony Stephens, and the first half of a beautiful, deeply poetic and haunting novel entitled Son, from the London-based writer and art-critic Jennifer Higgie. The novel’s second and final part will appear in PORTAL vol. 2, no. 1, in January 2005. On a different note, we would like to express our support for the inaugural Ubud Writers and Readers Festival, to be held in Ubud, Bali, from October 11 to 17, 2004. The Festival

  16. Knowledge Portals: Ontologies at Work

    OpenAIRE

    Staab, Steffen; Maedche, Alexander

    2001-01-01

    Knowledge portals provide views onto domain-specific information on the World Wide Web, thus helping their users find relevant, domain-specific information. The construction of intelligent access and the contribution of information to knowledge portals, however, remained an ad hoc task, requiring extensive manual editing and maintenance by the knowledge portal providers. To diminish these efforts, we use ontologies as a conceptual backbone for providing, accessing, and structuring information...

  17. Pregnancy with Portal Hypertension

    Science.gov (United States)

    Aggarwal, Neelam; Negi, Neha; Aggarwal, Aakash; Bodh, Vijay; Dhiman, Radha K.

    2014-01-01

    Even though pregnancy is rare with cirrhosis and advanced liver disease, but it may co-exist in the setting of non-cirrhotic portal hypertension as liver function is preserved but whenever encountered together is a complex clinical dilemma. Pregnancy in a patient with portal hypertension presents a special challenge to the obstetrician as so-called physiological hemodynamic changes associated with pregnancy, needed for meeting demands of the growing fetus, worsen the portal hypertension thereby putting mother at risk of potentially life-threatening complications like variceal hemorrhage. Risks of variceal bleed and hepatic decompensation increase many fold during pregnancy. Optimal management revolves round managing the portal hypertension and its complications. Thus management of such cases requires multi-speciality approach involving obstetricians experienced in dealing with high risk cases, hepatologists, anesthetists and neonatologists. With advancement in medical field, pregnancy is not contra-indicated in these women, as was previously believed. This article focuses on the different aspects of pregnancy with portal hypertension with special emphasis on specific cause wise treatment options to decrease the variceal bleed and hepatic decompensation. Based on extensive review of literature, management from pre-conceptional period to postpartum is outlined in order to have optimal maternal and perinatal outcomes. PMID:25755552

  18. Autonomous radiation monitoring of small vessels

    International Nuclear Information System (INIS)

    Ziock, K.P.; Cheriyadat, A.; Fabris, L.; Goddard, J.; Hornback, D.; Karnowski, T.; Kerekes, R.; Newby, J.

    2011-01-01

    Small private vessels are one avenue by which nuclear materials may be smuggled across international borders. While one can contemplate using the land-based approach of radiation portal monitors on the navigable waterways that lead to many ports, these systems are ill-suited to the problem. In contrast to roadways, where lanes segregate vehicles, and motion is well controlled by inspection booths; channels, inlets, and rivers present chaotic traffic patterns populated by vessels of all sizes. A unique solution to this problem is based on a portal-less portal monitor designed to handle free-flowing traffic on roadways with up to five-traffic lanes. The instrument uses a combination of visible-light and gamma-ray imaging to acquire and link radiation images to individual vehicles. This paper presents the results of a recent test of the system in a maritime setting.

  19. Periodic quality control of a linear accelerator using electronic portal imaging

    International Nuclear Information System (INIS)

    Planes Meseguer, D.; Dorado Rodriguez, M. P.; Esposito, R. D.

    2011-01-01

    In this paper we present our solution for the realization of the monthly periodic quality control (CP) geometry - mechanical and multi leaf collimator (MLC), using the electronic system for portal imaging (EPI). We have developed specific programs created with free software. The monitoring results are automatically stored on our web server, along with other information generated in our service.

  20. Blood in the gastric lumen increases splanchnic blood flow and portal pressure in portal-hypertensive rats.

    Science.gov (United States)

    Chen, L; Groszmann, R J

    1996-10-01

    In portal-hypertensive humans, portal blood flow and pressure increase after a meal. These hemodynamic changes may increase variceal rupture risk. The aim of this study was to determine whether blood in the stomach lumen increases splanchnic flow and portal pressure (PP) in portal-hypertensive rats. superior mesenteric artery flow and PP were measured in conscious, unrestrained, fasted partial portal vein-ligated rats with chronically implanted Doppler flow probes or portal vein catheters before and after gavage with heparinized, warmed blood from donor rats, air, standard meal, or empty tube. Percentage of changes in flow and pressure from baseline were significantly greater after gavage with blood (an increase of 22.6% +/- 3.5% and an increase of 16.4% +/- 3.1%, respectively) than empty tube (an increase of 3.4% +/- 0.6% and a decrease of 5.4% +/- 3.5%, respectively) (P empty tube (P calories probably contributes to these hemodynamic changes. In patients with variceal hemorrhage, blood in the stomach may increase the risk of persistent variceal bleeding or rebleeding.

  1. Portal vein stenting for delayed jejunal varix bleeding associated with portal venous occlusion after hepatoiliary and pancreatic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dong Ho; Park, Kwang Bo; Cho, Sung Ki; Park, Hong Suk; Shin, Sung Wook; Choo, Sung Wook; Do, Young Soo; Choo, In Wook; Choi, Dong Wook [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-09-15

    The study aimed to describe portal stenting for postoperative portal occlusion with delayed (≥ 3 months) variceal bleeding in the afferent jejunal loop. Eleven consecutive patients (age range, 2–79 years; eight men and three women) who underwent portal stenting between April 2009 and December 2015 were included in the study. Preoperative medical history and the postoperative clinical course were reviewed. Characteristics of portal occlusion and details of procedures were also investigated. Technical success, treatment efficacy (defined as disappearance of jejunal varix on follow-up CT), and clinical success were analyzed. Primary stent patency rate was plotted using the Kaplan-Meier method. All patients underwent hepatobiliary-pancreatic cancer surgery except two children with liver transplantation for biliary atresia. Portal occlusion was caused by benign postoperative change (n = 6) and local tumor recurrence (n = 5). Variceal bleeding occurred at 27 months (4 to 72 months) and portal stenting was performed at 37 months (4 to 121 months), on average, postoperatively. Technical success, treatment efficacy, and clinical success rates were 90.9, 100, and 81.8%, respectively. The primary patency rate of portal stent was 88.9% during the mean follow-up period of 9 months. Neither procedure-related complication nor mortality occurred. Interventional portal stenting is an effective treatment for delayed jejunal variceal bleeding due to portal occlusion after hepatobiliary-pancreatic surgery.

  2. Portal vein stenting for delayed jejunal varix bleeding associated with portal venous occlusion after hepatoiliary and pancreatic surgery

    International Nuclear Information System (INIS)

    Hyun, Dong Ho; Park, Kwang Bo; Cho, Sung Ki; Park, Hong Suk; Shin, Sung Wook; Choo, Sung Wook; Do, Young Soo; Choo, In Wook; Choi, Dong Wook

    2017-01-01

    The study aimed to describe portal stenting for postoperative portal occlusion with delayed (≥ 3 months) variceal bleeding in the afferent jejunal loop. Eleven consecutive patients (age range, 2–79 years; eight men and three women) who underwent portal stenting between April 2009 and December 2015 were included in the study. Preoperative medical history and the postoperative clinical course were reviewed. Characteristics of portal occlusion and details of procedures were also investigated. Technical success, treatment efficacy (defined as disappearance of jejunal varix on follow-up CT), and clinical success were analyzed. Primary stent patency rate was plotted using the Kaplan-Meier method. All patients underwent hepatobiliary-pancreatic cancer surgery except two children with liver transplantation for biliary atresia. Portal occlusion was caused by benign postoperative change (n = 6) and local tumor recurrence (n = 5). Variceal bleeding occurred at 27 months (4 to 72 months) and portal stenting was performed at 37 months (4 to 121 months), on average, postoperatively. Technical success, treatment efficacy, and clinical success rates were 90.9, 100, and 81.8%, respectively. The primary patency rate of portal stent was 88.9% during the mean follow-up period of 9 months. Neither procedure-related complication nor mortality occurred. Interventional portal stenting is an effective treatment for delayed jejunal variceal bleeding due to portal occlusion after hepatobiliary-pancreatic surgery

  3. TMEM16A regulates portal vein smooth muscle cell proliferation in portal hypertension.

    Science.gov (United States)

    Zeng, Xi; Huang, Ping; Chen, Mingkai; Liu, Shiqian; Wu, Nannan; Wang, Fang; Zhang, Jing

    2018-01-01

    The aim of the present study was to elucidate the effect of transmembrane protein 16A (TMEM16A) on portal vein smooth muscle cell (PVSMC) proliferation associated with portal vein remodeling in portal hypertension (PHT). Sprague-Dawley rats were subjected to bile duct ligation to establish a rat model of liver cirrhosis and PHT. Sham-operated animals served as controls. At 8 weeks after bile duct ligation, the extent of liver fibrosis and the portal vein wall thickness were assessed using hematoxylin-eosin staining. The protein expression levels of TMEM16A, extracellular signal-regulated kinase 1 and 2 (ERK1/2) and phosphorylated ERK1/2 (p-ERK1/2) in the portal vein were detected by immunohistochemistry and western blotting. In vitro , the lentivirus vectors were constructed and transfected into PVSMCs to upregulate the expression of TMEM16A. Isolated rat primary PVSMCs were treated with a small molecule inhibitor of TMEM16A, T16A-inhA01. Cell cycle was detected by flow cytometry. The activity of TMEM16A in the portal vein isolated from bile duct ligated rats was decreased, while the expression level of p-ERK1/2 was increased. However, in vitro , upregulation of TMEM16A promoted the proliferation PVSMCs, while inhibition of TMEM16A channels inhibited the proliferation of PVSMCs. The results indicated that TMEM16A contributes to PVSMCs proliferation in vitro , but in vivo , it may be a negative regulator of cell proliferation influenced by numerous factors.

  4. Cavernous transformation of the portal vein

    International Nuclear Information System (INIS)

    Lehotska, V.; Dostalova, K.; Durkovsky, A.; Samal, V.

    1995-01-01

    In this contribution, the authors give an account of a rare case of a cavernous transformation of the portal vein that may have originated secondarily in a proliferative hematogenous disease with a polyglobulia and thrombosis in the periferal blood count as well as development of portal hypertension of a prehepatal type. The state of hyper-coagulation in a myeloproliferative disease may have lead to a chronic thrombosis of the portal vein with a subsequent malformation of the portal vein in terms of a cavernous transformation of the portal vein. The case is an interesting one because of the discrepancy between the gravity of the thrombotic complication and slightness of the symptoms in the clinical picture. The authors point out the importance of ultrasonography and computed tomography examination following the intravenous application of a water solution of a contrast medium in a morphologic diagnosing of a rare complication of a chronic thrombotic clot of the portal vein - the cavernous transformation. (authors)

  5. Development of NORM determination Algorithm for Radiation Portal Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hwan; Kim, Ye Won; Yoo, Hyun Jun; Kim, Chan Kyu; Lee, Sang Heon; Cho, Gyu Seong [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, probability of distinguishing nuclide analysis is proposed by measuring compton energy spectrum of gamma ray with large-area PVT scintillator to solve fundamental problem. US coast guard (USCG) suggested the methods for which terrorism could be prevented to international maritime organization (IMO) and the bill in which container safety was assured was suggested by U.S customs officials. However, radiation portal monitors (RPMs) running at the airport and the harbor cannot distinguish special cargo material (SNM) from naturally occurring radioactive materials (NOMR) containing a small dose of radioisotope from nature. Consequently, cargo sorted out by RPM using polyvinyl-toluene (PVT) scintillator contains approximately 99% of NORM (such as cat litter, potash, tableware and etc.) Many research institutes are under way to reduce such a nuisance alarm. Tom Burr conducted pattern recognition methods with extracted 184 features (46 features from each of four panels) from 235 profiles out of 406 profiles representing gamma alarm. But this method is more like statistical analysis using the data of low and high gamma than practical nuclide analysis. So it has limitation to reduce nuisance alarm. Regarding to the experimental result for difference distances between the source and the scintillator using large-area PVT based plastic scintillator, the linearity was not secured when the distance is from 0cm to 20cm. It is expected that, for these cases, the scintillation areas in which photon is emitted were small. The distance between PMTs and these areas was too far to detect every emitted photon because the photons were attenuated by plastic scintillator. Because of this reason, energy spectra were shifted to relatively lower channel. While, no more spectrum shifting occurred for 50cm and 100cm. It is considered that the increase of the gamma source solid angle makes scintillation area larger and no more spectrum shifting occur. With this experiment, it was

  6. Development of NORM determination Algorithm for Radiation Portal Monitors

    International Nuclear Information System (INIS)

    Kim, Jin Hwan; Kim, Ye Won; Yoo, Hyun Jun; Kim, Chan Kyu; Lee, Sang Heon; Cho, Gyu Seong

    2016-01-01

    In this paper, probability of distinguishing nuclide analysis is proposed by measuring compton energy spectrum of gamma ray with large-area PVT scintillator to solve fundamental problem. US coast guard (USCG) suggested the methods for which terrorism could be prevented to international maritime organization (IMO) and the bill in which container safety was assured was suggested by U.S customs officials. However, radiation portal monitors (RPMs) running at the airport and the harbor cannot distinguish special cargo material (SNM) from naturally occurring radioactive materials (NOMR) containing a small dose of radioisotope from nature. Consequently, cargo sorted out by RPM using polyvinyl-toluene (PVT) scintillator contains approximately 99% of NORM (such as cat litter, potash, tableware and etc.) Many research institutes are under way to reduce such a nuisance alarm. Tom Burr conducted pattern recognition methods with extracted 184 features (46 features from each of four panels) from 235 profiles out of 406 profiles representing gamma alarm. But this method is more like statistical analysis using the data of low and high gamma than practical nuclide analysis. So it has limitation to reduce nuisance alarm. Regarding to the experimental result for difference distances between the source and the scintillator using large-area PVT based plastic scintillator, the linearity was not secured when the distance is from 0cm to 20cm. It is expected that, for these cases, the scintillation areas in which photon is emitted were small. The distance between PMTs and these areas was too far to detect every emitted photon because the photons were attenuated by plastic scintillator. Because of this reason, energy spectra were shifted to relatively lower channel. While, no more spectrum shifting occurred for 50cm and 100cm. It is considered that the increase of the gamma source solid angle makes scintillation area larger and no more spectrum shifting occur. With this experiment, it was

  7. Morphological and biomechanical remodeling of the hepatic portal vein in a swine model of portal hypertension.

    Science.gov (United States)

    He, Xi-Ju; Huang, Tie-Zhu; Wang, Pei-Jun; Peng, Xing-Chun; Li, Wen-Chun; Wang, Jun; Tang, Jie; Feng, Na; Yu, Ming-Hua

    2012-02-01

    To obtain the morphological and biomechanical remodeling of portal veins in swine with portal hypertension (PHT), so as to provide some mechanical references and theoretical basis for clinical practice about PHT. Twenty white pigs were used in this study, 14 of them were subjected to both carbon tetrachloride- and pentobarbital-containing diet to induce experimental liver cirrhosis and PHT, and the remaining animals served as the normal controls. The morphological remodeling of portal veins was observed. Endothelial nitric oxide synthase expression profile in the vessel wall was assessed at both mRNA and protein level. The biomechanical changes of the hepatic portal veins were evaluated through assessing the following indicators: the incremental elastic modulus, pressure-strain elastic modulus, volume elastic modulus, and the incremental compliance. The swine PHT model was successfully established. The percentages for the microstructural components and the histological data significantly changed in the experimental group. Endothelial nitric oxide synthase expression was significantly downregulated in the portal veins of the experimental group. Three incremental elastic moduli (the incremental elastic modulus, pressure-strain elastic modulus, and volume elastic modulus) of the portal veins from PHT animals were significantly larger than those of the controls (P portal vein decreased. Our study suggests that the morphological and biomechanical properties of swine hepatic portal veins change significantly during the PHT process, which may play a critical role in the development of PHT and serve as potential therapeutic targets during clinical practice. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  8. Web-based Service Portal in Healthcare

    Science.gov (United States)

    Silhavy, Petr; Silhavy, Radek; Prokopova, Zdenka

    Information delivery is one the most important task in healthcare. The growing sector of electronic healthcare has an important impact on the information delivery. There are two basic approaches towards information delivering. The first is web portal and second is touch-screen terminal. The aim of this paper is to investigate the web-based service portal. The most important advantage of web-based portal in the field of healthcare is an independent access for patients. This paper deals with the conditions and frameworks for healthcare portals

  9. Interactive web-based portals to improve patient navigation and connect patients with primary care and specialty services in underserved communities.

    Science.gov (United States)

    Highfield, Linda; Ottenweller, Cecelia; Pfanz, Andre; Hanks, Jeanne

    2014-01-01

    This article presents a case study in the redesign, development, and implementation of a web-based healthcare clinic search tool for virtual patient navigation in underserved populations in Texas. It describes the workflow, assessment of system requirements, and design and implementation of two online portals: Project Safety Net and the Breast Health Portal. The primary focus of the study was to demonstrate the use of health information technology for the purpose of bridging the gap between underserved populations and access to healthcare. A combination of interviews and focus groups was used to guide the development process. Interviewees were asked a series of questions about usage, usability, and desired features of the new system. The redeveloped system offers a multitier architecture consisting of data, business, and presentation layers. The technology used in the new portals include Microsoft .NET Framework 3.5, Microsoft SQL Server 2008, Google Maps JavaScript API v3, jQuery, Telerik RadControls (ASP.NET AJAX), and HTML. The redesigned portals have 548 registered clinics, and they have averaged 355 visits per month since their launch in late 2011, with the average user visiting five pages per visit. Usage has remained relatively constant over time, with an average of 142 new users (40 percent) each month. This study demonstrates the successful application of health information technology to improve access to healthcare and the successful adoption of the technology by targeted end users. The portals described in this study could be replicated by health information specialists in other areas of the United States to address disparities in healthcare access.

  10. Intelligent interaction based on holographic personalized portal

    Directory of Open Access Journals (Sweden)

    Yadong Huang

    2017-06-01

    Full Text Available Purpose – The purpose of this paper is to study the architecture of holographic personalized portal, user modeling, commodity modeling and intelligent interaction. Design/methodology/approach – In this paper, the authors propose crowd-science industrial ecological system based on holographic personalized portal and its interaction. The holographic personality portal is based on holographic enterprises, commodities and consumers, and the personalized portal consists of accurate ontology, reliable supply, intelligent demand and smart cyberspace. Findings – The personalized portal can realize the information acquisition, characteristic analysis and holographic presentation. Then, the intelligent interaction, e.g. demand decomposition, personalized search, personalized presentation and demand prediction, will be implemented within the personalized portal. Originality/value – The authors believe that their work on intelligent interaction based on holographic personalized portal, which has been first proposed in this paper, is innovation focusing on the interaction between intelligence and convenience.

  11. eHealth Literacy: Patient Engagement in Identifying Strategies to Encourage Use of Patient Portals Among Older Adults.

    Science.gov (United States)

    Price-Haywood, Eboni G; Harden-Barrios, Jewel; Ulep, Robin; Luo, Qingyang

    2017-12-01

    Innovations in chronic disease management are growing rapidly as advancements in technology broaden the scope of tools. Older adults are less likely to be willing or able to use patient portals or smartphone apps for health-related tasks. The authors conducted a cross-sectional survey of older adults (ages ≥50) with hypertension or diabetes to examine relationships between portal usage, interest in health-tracking tools, and eHealth literacy, and to solicit practical solutions to encourage technology adoption. Among 247 patients surveyed in a large integrated delivery health system between August 2015 and January 2016, eHealth literacy was positively associated with portal usage (OR [95% CI]: 1.3 [1.2-1.5]) and interest in health-tracking tools (1.2 [1.1-1.3]). Portal users compared to nonusers (N = 137 vs.110) had higher rates of interest in using websites/smartphone apps to track blood pressure (55% vs. 36%), weight (53% vs. 35%), exercise (53% vs. 32%), or medication (46% vs 33%, all P marketing initiatives that capture patient stories demonstrating real-life applications of what patients can do with digital technology, how to use it, and why it may be useful. Health systems also must screen for eHealth literacy, provide training, promote proxy users, and institute quality assurance that ensures patients' experiences will not vary across the system.

  12. Electronic patient portals: evidence on health outcomes, satisfaction, efficiency, and attitudes: a systematic review.

    Science.gov (United States)

    Goldzweig, Caroline Lubick; Orshansky, Greg; Paige, Neil M; Towfigh, Ali Alexander; Haggstrom, David A; Miake-Lye, Isomi; Beroes, Jessica M; Shekelle, Paul G

    2013-11-19

    Patient portals tied to provider electronic health record (EHR) systems are increasingly popular. To systematically review the literature reporting the effect of patient portals on clinical care. PubMed and Web of Science searches from 1 January 1990 to 24 January 2013. Hypothesis-testing or quantitative studies of patient portals tethered to a provider EHR that addressed patient outcomes, satisfaction, adherence, efficiency, utilization, attitudes, and patient characteristics, as well as qualitative studies of barriers or facilitators, were included. Two reviewers independently extracted data and addressed discrepancies through consensus discussion. From 6508 titles, 14 randomized, controlled trials; 21 observational, hypothesis-testing studies; 5 quantitative, descriptive studies; and 6 qualitative studies were included. Evidence is mixed about the effect of portals on patient outcomes and satisfaction, although they may be more effective when used with case management. The effect of portals on utilization and efficiency is unclear, although patient race and ethnicity, education level or literacy, and degree of comorbid conditions may influence use. Limited data for most outcomes and an absence of reporting on organizational and provider context and implementation processes. Evidence that patient portals improve health outcomes, cost, or utilization is insufficient. Patient attitudes are generally positive, but more widespread use may require efforts to overcome racial, ethnic, and literacy barriers. Portals represent a new technology with benefits that are still unclear. Better understanding requires studies that include details about context, implementation factors, and cost.

  13. qPortal: A platform for data-driven biomedical research.

    Science.gov (United States)

    Mohr, Christopher; Friedrich, Andreas; Wojnar, David; Kenar, Erhan; Polatkan, Aydin Can; Codrea, Marius Cosmin; Czemmel, Stefan; Kohlbacher, Oliver; Nahnsen, Sven

    2018-01-01

    Modern biomedical research aims at drawing biological conclusions from large, highly complex biological datasets. It has become common practice to make extensive use of high-throughput technologies that produce big amounts of heterogeneous data. In addition to the ever-improving accuracy, methods are getting faster and cheaper, resulting in a steadily increasing need for scalable data management and easily accessible means of analysis. We present qPortal, a platform providing users with an intuitive way to manage and analyze quantitative biological data. The backend leverages a variety of concepts and technologies, such as relational databases, data stores, data models and means of data transfer, as well as front-end solutions to give users access to data management and easy-to-use analysis options. Users are empowered to conduct their experiments from the experimental design to the visualization of their results through the platform. Here, we illustrate the feature-rich portal by simulating a biomedical study based on publically available data. We demonstrate the software's strength in supporting the entire project life cycle. The software supports the project design and registration, empowers users to do all-digital project management and finally provides means to perform analysis. We compare our approach to Galaxy, one of the most widely used scientific workflow and analysis platforms in computational biology. Application of both systems to a small case study shows the differences between a data-driven approach (qPortal) and a workflow-driven approach (Galaxy). qPortal, a one-stop-shop solution for biomedical projects offers up-to-date analysis pipelines, quality control workflows, and visualization tools. Through intensive user interactions, appropriate data models have been developed. These models build the foundation of our biological data management system and provide possibilities to annotate data, query metadata for statistics and future re-analysis on

  14. A University Web Portal redesign applying accessibility patterns. Breaking Down Barriers for Visually Impaired Users

    Directory of Open Access Journals (Sweden)

    Hernán Sosa

    2015-08-01

    Full Text Available Definitely, the WWW and ICTs have become the preferred media for the interaction between society and its citizens, and public and private organizations have today the possibility of deploying their activities through the Web. In particular, university education is a domain where the benefits of these technological resources can strongly contribute in caring for students. However, most university Web portals are inaccessible to their user community (students, professors, and non-teaching staff, between others, since these portals do not take into account the needs of people with different capabilities. In this work, we propose an accessibility pattern driven process to the redesign of university Web portals, aiming to break down barriers for visually impaired users. The approach is implemented to a real case study: the Web portal of Universidad Nacional de la Patagonia Austral (UNPA. The results come from applying accessibility recommendations and evaluation tools (automatic and manual from internationally recognized organizations, to both versions of the Web portal: the original and the redesign one.

  15. Editor's welcome, PORTAL, Vol. 2, No. 2, July 2005

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2005-08-01

    Full Text Available Welcome to the July 2005 issue of Portal, a special issue with the title ‘Strange Localities: Utopias, Intellectuals and Identities in the 21st Century,’ guest edited by Alistair Fox and Hilary Radner (both from the University of Otago, New Zealand, who convened an international colloquium on this theme in January 2004, and Murray Pratt (University of Technology Sydney, Australia. As Alistair Fox says in his introduction to the special issue, the twelve papers gathered under the ‘Strange Localities’ rubric provide rich insights into the ways by which ‘the contemporary utopian impulse is expressing itself, both in the search for utopia, and through the exposure of false utopias.’ With a broad geographical reach, and an equally broad critical gaze, the essays collected here shed new light on the critical, yet often ambivalent, role that identity politics play in myriad utopian projects, and also in such critical enterprises and epoch-defining processes as postcolonialism, postfeminism, postmodernism, transnationalism, multiculturalism, and economic and cultural globalization. In addition to the papers collected in the special issue section, this issue of Portal includes a number of essays that, while not addressing the special issue theme, also have much to say about the nexus between contemporary identity debates, intellectual practice, and utopian imaginaries. We are also pleased to introduce in the Portal Cultural Works' section two short chronicle-like pieces by Moses Iten, a young Australian writer. Paul Allatson, Chair, PORTAL Editorial Committee

  16. Beneficial long term effect of a phosphodiesterase-5-inhibitor in cirrhotic portal hypertension: A case report with 8 years follow-up.

    Science.gov (United States)

    Deibert, Peter; Lazaro, Adhara; Stankovic, Zoran; Schaffner, Denise; Rössle, Martin; Kreisel, Wolfgang

    2018-01-21

    Non-selective beta-blockers are the mainstay of medical therapy for portal hypertension in liver cirrhosis. Inhibitors of phosphodiesterase-5 (PDE-5-inhibitors) reduce portal pressure in the acute setting by > 10% which may suggest a long-term beneficial effect. Currently, there is no available data on long-term treatment of portal hypertension with PDE-5-inhibitors. This case of a patient with liver cirrhosis secondary to autoimmune liver disease with episodes of bleeding from esophageal varices is the first documented case in which a treatment with a PDE-5-inhibitor for eight years was monitored. In the acute setting, the PDE-5-inhibitor Vardenafil lowered portal pressure by 13%. The portal blood flow increased by 28% based on Doppler sonography and by 16% using MRI technique. As maintenance medication the PDE-5-inhibitor Tadalafil was used for eight consecutive years with comparable effects on portal pressure and portal blood flow. There were no recurrence of bleeding and no formation of new varices. Influencing the NO-pathway by the use of PDE-5 inhibitors may have long-term beneficial effects in compensated cirrhosis.

  17. Radioisotopic evaluation of portal circulation

    International Nuclear Information System (INIS)

    Maliska, C.; Rosenthal, D.

    1986-01-01

    The use of a radio-tracer of portal circulation through the intestine, should prevent cruel punctures in the portal-vein or spleen as it is usually the case with traditional methods in the study of portal-system. The absorption of I-131 and Tc-99m, previously cheked in rabbits presented similar results in dogs. The time of circulation between terminal large-intestine and the liver (t-RF) was determined by external counting at hepatic level by recording radioactivity variation-time. In healthy animals the t-RF was from 20to 60 seconds, with average time of 42 seconds. In 2 animals with partial binding of portal-vein the t-RF went up to 110 and 120 seconds. (Author) [pt

  18. OntoFire: an ontology-based geo-portal for wildfires

    Science.gov (United States)

    Kalabokidis, K.; Athanasis, N.; Vaitis, M.

    2011-12-01

    With the proliferation of the geospatial technologies on the Internet, the role of geo-portals (i.e. gateways to Spatial Data Infrastructures) in the area of wildfires management emerges. However, keyword-based techniques often frustrate users when looking for data of interest in geo-portal environments, while little attention has been paid to shift from the conventional keyword-based to navigation-based mechanisms. The presented OntoFire system is an ontology-based geo-portal about wildfires. Through the proposed navigation mechanisms, the relationships between the data can be discovered, which would otherwise not be possible when using conventional querying techniques alone. End users can use the browsing interface to find resources of interest by using the navigation mechanisms provided. Data providers can use the publishing interface to submit new metadata, modify metadata or removing metadata in/from the catalogue. The proposed approach can improve the discovery of valuable information that is necessary to set priorities for disaster mitigation and prevention strategies. OntoFire aspires to be a focal point of integration and management of a very large amount of information, contributing in this way to the dissemination of knowledge and to the preparedness of the operational stakeholders.

  19. ONLINE TECHNOLOGICAL MONITORING OF INSULATION DEFECTS IN ENAMELED WIRES

    Directory of Open Access Journals (Sweden)

    V. M. Zolotaryov

    2017-08-01

    Full Text Available In this paper the authors used non-destructive technological monitoring of defects insulation enameled wire with poliimid polymer. The paper is devoted to the statistical method for processing, comparison and analysis of results of measurements of parameters of insulation of enameled wire because of mathematical model of trend for application in active technological monitoring is developed; the recommendations for parameters of such monitoring are used. It is theoretically justified and the possibility of determination of dependence of the error on the velocity of movement of a wire for want of quantifying of defects in enameled insulation by non-destructive tests by high voltage. The dependence of average value of amount of defects for enameled wire with two-sheeted poliimid insulation in a range of nominal diameter 0.56 mm is experimentally determined. The technological monitoring purpose is to reduce the quantifying defects of enameled insulation.

  20. Technology monitoring in the CIEMAT; La vigilancia tecnologica en el CIEMAT

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Martinez, M.; Cuesta, M. J.; Crespi, S. N.; Cabrera, J. A.

    2008-07-01

    The CIEMAT Foresight and Technology Monitoring Unit focuses its activities on obtaining strategic information on future developments in the area of energy and environment that can be used for decision making by the centers management. In addition, it provides services to CIEMAT researchers and other external customers. In May 2007, the Asociacion Espanola de Normalizacion y Certificacion AENOR delivered to the CIEMAT the first Technology Monitoring System certificate granted in Spain as per standard UNE 166006:2006. This article describes the Units experience in the implementation process of the Technology Monitoring System and provides several examples of the way in which the Unit graphically represents the information analyzed in its Technology Monitoring Reports. (Author)

  1. Pathology of idiopathic non-cirrhotic portal hypertension.

    Science.gov (United States)

    Guido, Maria; Sarcognato, Samantha; Sacchi, Diana; Colloredo, Guido

    2018-04-12

    Idiopathic non-cirrhotic portal hypertension is an under-recognized vascular liver disease of unknown etiology, characterized by clinical signs of portal hypertension in the absence of cirrhosis. By definition, any disorder known to cause portal hypertension in the absence of cirrhosis and any cause of chronic liver disease must be excluded to make a diagnosis of idiopathic non-cirrhotic portal hypertension. However, the diagnosis is often difficult because the disease resembles cirrhosis and there is no gold standard test. Liver biopsy is an essential tool: it is able to exclude cirrhosis and other causes of portal hypertension and it allows the identification of the characteristic lesions. Nonetheless, the histological diagnosis of idiopathic non-cirrhotic portal hypertension is not always straightforward, in particular by needle biopsy samples, because there is no pathognomonic lesion, but rather a variety of vascular changes which are unevenly distributed, very subtle, and not all necessarily identified in a single specimen. Pathologists should be able to recognize several patterns of injury, involving portal/periportal areas as well as parenchymal structures.The histological features of idiopathic non-cirrhotic portal hypertension are described in this review, focusing on their interpretation in needle biopsy specimens.

  2. Corporate portal system at PAKS NPP, Hungary

    International Nuclear Information System (INIS)

    2009-01-01

    The new Corporate Portal System (CPS) of Paks NPP was launched in November 2006. The portal is based on one of the latest technologies, Plumtree Enterprise WEB 5.0. The main purpose of the installation of the new technology was to serve the working culture change, to give a platform to access all information and applications including the integrated process model used at the NPP. The new technology also supports those goals which were defined in the organization development programme: e.g. to improve internal communication with the establishment of communities of practice. Installation of the CPS has provided a powerful tool for knowledge management; it is possible to share and find all information through a controlled access in documents from various sources, to have links to people, portlets and different communities. Document management of the Paks NPP is supported by the integration of the Document 5 application, as the new Electronic Data Management System (EDMS) and the CPS. Depending on their access rights, all users of the CPS, through Microsoft Internet Explorer, can access technical, economic and human resources documents which are stored anywhere on the internal network (file servers, EDMS, old INRANET). The CPS is also accessible from the internet through a secure connection. The main concept is the integration of all applications to one platform and to help users to find all information they need. An access control list specifies which users and groups have access to an object (and what kind of access privileges they have such as read, select, edit, admin)

  3. Literature review on monitoring technologies and their outcomes in independently living elderly people.

    Science.gov (United States)

    Peetoom, Kirsten K B; Lexis, Monique A S; Joore, Manuela; Dirksen, Carmen D; De Witte, Luc P

    2015-07-01

    To obtain insight into what kind of monitoring technologies exist to monitor activity in-home, what the characteristics and aims of applying these technologies are, what kind of research has been conducted on their effects and what kind of outcomes are reported. A systematic document search was conducted within the scientific databases Pubmed, Embase, Cochrane, PsycINFO and Cinahl, complemented by Google Scholar. Documents were included in this review if they reported on monitoring technologies that detect activities of daily living (ADL) or significant events, e.g. falls, of elderly people in-home, with the aim of prolonging independent living. Five main types of monitoring technologies were identified: PIR motion sensors, body-worn sensors, pressure sensors, video monitoring and sound recognition. In addition, multicomponent technologies and smart home technologies were identified. Research into the use of monitoring technologies is widespread, but in its infancy, consisting mainly of small-scale studies and including few longitudinal studies. Monitoring technology is a promising field, with applications to the long-term care of elderly persons. However, monitoring technologies have to be brought to the next level, with longitudinal studies that evaluate their (cost-) effectiveness to demonstrate the potential to prolong independent living of elderly persons. [Box: see text].

  4. Novel Rat Model of Repetitive Portal Venous Embolization Mimicking Human Non-Cirrhotic Idiopathic Portal Hypertension

    DEFF Research Database (Denmark)

    Klein, Sabine; Hinüber, Christian; Hittatiya, Kanishka

    2016-01-01

    BACKGROUND: Non-cirrhotic idiopathic portal hypertension (NCIPH) is characterized by splenomegaly, anemia and portal hypertension, while liver function is preserved. However, no animal models have been established yet. This study assessed a rat model of NCIPH and characterized the hemodynamics......, and compared it to human NCIPH. METHODS: Portal pressure (PP) was measured invasively and coloured microspheres were injected in the ileocecal vein in rats. This procedure was performed weekly for 3 weeks (weekly embolization). Rats without and with single embolization served as controls. After four weeks (one...... in the weekly embolization group. Fibrotic markers αSMA and Desmin were upregulated in weekly embolized rats. DISCUSSION: This study establishes a model using repetitive embolization via portal veins, comparable with human NCIPH and may serve to test new therapies....

  5. Idiopathic Noncirrhotic Portal Hypertension: An Appraisal

    Science.gov (United States)

    Lee, Hwajeong; Rehman, Aseeb Ur; Fiel, M. Isabel

    2016-01-01

    Idiopathic noncirrhotic portal hypertension is a poorly defined clinical condition of unknown etiology. Patients present with signs and symptoms of portal hypertension without evidence of cirrhosis. The disease course appears to be indolent and benign with an overall better outcome than cirrhosis, as long as the complications of portal hypertension are properly managed. This condition has been recognized in different parts of the world in diverse ethnic groups with variable risk factors, resulting in numerous terminologies and lack of standardized diagnostic criteria. Therefore, although the diagnosis of idiopathic noncirrhotic portal hypertension requires clinical exclusion of other conditions that can cause portal hypertension and histopathologic confirmation, this entity is under-recognized clinically as well as pathologically. Recent studies have demonstrated that variable histopathologic entities with different terms likely represent a histologic spectrum of a single entity of which obliterative portal venopathy might be an underlying pathogenesis. This perception calls for standardization of the nomenclature and formulation of widely accepted diagnostic criteria, which will facilitate easier recognition of this disorder and will highlight awareness of this entity. PMID:26563701

  6. Feasibility of a Website and a Hospital-Based Online Portal for Young Adults With Juvenile Idiopathic Arthritis: Views and Experiences of Patients.

    Science.gov (United States)

    Ammerlaan, Judy Jw; Scholtus, Lieske W; Drossaert, Constance Hc; van Os-Medendorp, Harmieke; Prakken, Berent; Kruize, Aike A; Bijlsma, Johannes Jw

    2015-08-14

    To improve knowledge and to encourage active involvement of young adults with juvenile idiopathic arthritis (JIA), an informative website with written and video information and an online portal with access to the personal medical record, self-monitoring, and e-consult functionalities were developed. Before implementing these applications in daily practice, it is important to gain insight into their feasibility in terms of ease of use, perceived usefulness and intention to use. The aim of this study was to evaluate and to examine the feasibility of the website and the online portal for young adults with JIA. A qualitative, feasibility study was conducted among the first users: 13 young adults with JIA. After provided access to the website and online portal, patients were interviewed on perceived usefulness, ease of use, and intention to (re)use the applications. Participants in the study considered the website and online portal as useful and easy-to-use. New medical information and feedback would motivate them to revisit the applications again. On the website, videos showing other young adults, telling how they handle their condition, were found as the most useful. On the portal, access to their medical records was most appreciated: it made the young JIA patients feel in control and it helped them monitor symptoms and disease activity. e-consults were thought to facilitate communication with physicians. The young adults considered both the website and the online portal as feasible, but they also had valuable suggestions to improve accessibility and use. Based on these findings, a news and event section was added on the website and a direct link was made to a discussion board and social media. To provide and support health information, the website is actively used in daily care. Considering the online portal, the use of self-monitoring tools and e-consult can be stimulated if there is direct linkage to treatment and feedback from the multidisciplinary team

  7. On the Efficiency of Spam Mailing and Portal Advertising

    OpenAIRE

    Martin Bandulet

    2005-01-01

    The objective of this paper is to provide a simple approach endogenizing the welfare reducing or welfare enhancing effect of informative advertising. Using this approach, it is possible to analyse the welfare consequences of a technology shock that reduces unit information costs, and to explain whether electronic junk mails or portal advertising will cause welfare gains or losses in a competitive environment.

  8. U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: ARSENIC MONITORING TECHNOLOGIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency Environmental Technology Verification (ETV) program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This technology ...

  9. [Predictive value of ultrasonography in portal hypertension].

    Science.gov (United States)

    Moreno, E; Torres, P; Trejo, C; Barra Ostoni, V; Ortega, C; Römer, H

    1991-01-01

    Portal hypertension is a common pathology in childhood and one of its most common causes is cavernomatosis of the portal vein. This obstruction causes hemodynamic changes which lead to splenomegaly and collateral circulation. Esophageal varices are one of the most important sequelae, which endanger the patient's life because of a bleeding tendency. Ecosonography helps to detect the thickening of the lesser omentum vis a vis the aortic diameter, caused by the collateral circulation. We studied 15 children presenting with portal hypertension resulting from portal vein cavernomatosis; we performed an upper GI endoscopy and abdominal ecosonography. The endoscopy revealed grade II esophageal varices in 20% of cases, the remaining 80% had grade III and grade IV. Ecosonography revealed an increased lesser omentum/aorta ratio in children with portal hypertension, compared to controls (p portal hypertension.

  10. Migration monitoring with automated technology

    Science.gov (United States)

    Rhonda L. Millikin

    2005-01-01

    Automated technology can supplement ground-based methods of migration monitoring by providing: (1) unbiased and automated sampling; (2) independent validation of current methods; (3) a larger sample area for landscape-level analysis of habitat selection for stopover, and (4) an opportunity to study flight behavior. In particular, radar-acoustic sensor fusion can...

  11. Differences in Access to and Preferences for Using Patient Portals and Other eHealth Technologies Based on Race, Ethnicity, and Age: A Database and Survey Study of Seniors in a Large Health Plan.

    Science.gov (United States)

    Gordon, Nancy P; Hornbrook, Mark C

    2016-03-04

    results, or order prescription refills. Across all age groups, non-Hispanic whites and Chinese seniors were significantly more likely than black, Latino, and Filipino seniors to be registered and to have performed these actions. The survey found that black, Latino, and Filipino seniors and those 75 years old and older were significantly less likely to own digital devices (e.g., computers, smartphones), use the Internet and email, and be able and willing to use digital technology to perform health care-related tasks, including obtaining health information, than non-Hispanic whites, Chinese, and younger seniors (aged 65-69), respectively. The preference for using non-digital modalities persisted even among Internet users. Health plans, government agencies, and other organizations that serve diverse groups of seniors should include social determinants such as race/ethnicity and age when monitoring trends in eHealth to ensure that eHealth disparities do not induce greater health status and health care disparities between more privileged and less privileged groups.

  12. The GENIUS Grid Portal and robot certificates: a new tool for e-Science.

    Science.gov (United States)

    Barbera, Roberto; Donvito, Giacinto; Falzone, Alberto; La Rocca, Giuseppe; Milanesi, Luciano; Maggi, Giorgio Pietro; Vicario, Saverio

    2009-06-16

    Grid technology is the computing model which allows users to share a wide pletora of distributed computational resources regardless of their geographical location. Up to now, the high security policy requested in order to access distributed computing resources has been a rather big limiting factor when trying to broaden the usage of Grids into a wide community of users. Grid security is indeed based on the Public Key Infrastructure (PKI) of X.509 certificates and the procedure to get and manage those certificates is unfortunately not straightforward. A first step to make Grids more appealing for new users has recently been achieved with the adoption of robot certificates. Robot certificates have recently been introduced to perform automated tasks on Grids on behalf of users. They are extremely useful for instance to automate grid service monitoring, data processing production, distributed data collection systems. Basically these certificates can be used to identify a person responsible for an unattended service or process acting as client and/or server. Robot certificates can be installed on a smart card and used behind a portal by everyone interested in running the related applications in a Grid environment using a user-friendly graphic interface. In this work, the GENIUS Grid Portal, powered by EnginFrame, has been extended in order to support the new authentication based on the adoption of these robot certificates. The work carried out and reported in this manuscript is particularly relevant for all users who are not familiar with personal digital certificates and the technical aspects of the Grid Security Infrastructure (GSI). The valuable benefits introduced by robot certificates in e-Science can so be extended to users belonging to several scientific domains, providing an asset in raising Grid awareness to a wide number of potential users. The adoption of Grid portals extended with robot certificates, can really contribute to creating transparent access to

  13. Monitoring technologies for ocean disposal of radioactive waste

    Science.gov (United States)

    Triplett, M. B.; Solomon, K. A.; Bishop, C. B.; Tyce, R. C.

    1982-01-01

    The feasibility of using carefully selected subseabed locations to permanently isolate high level radioactive wastes at ocean depths greater than 4000 meters is discussed. Disposal at several candidate subseabed areas is being studied because of the long term geologic stability of the sediments, remoteness from human activity, and lack of useful natural resources. While the deep sea environment is remote, it also poses some significant challenges for the technology required to survey and monitor these sites, to identify and pinpoint container leakage should it occur, and to provide the environmental information and data base essential to determining the probable impacts of any such occurrence. Objectives and technical approaches to aid in the selective development of advanced technologies for the future monitoring of nuclear low level and high level waste disposal in the deep seabed are presented. Detailed recommendations for measurement and sampling technology development needed for deep seabed nuclear waste monitoring are also presented.

  14. Investigation of energy windowing algorithms for effective cargo screening with radiation portal monitors

    International Nuclear Information System (INIS)

    Hevener, Ryne; Yim, Man-Sung; Baird, Ken

    2013-01-01

    Radiation portal monitors (RPMs) are distributed across the globe in an effort to decrease the illicit trafficking of nuclear materials. Many current generation RPMs utilizes large polyvinyltoluene (PVT) plastic scintillators. These detectors are low cost and reliable but have very poor energy resolution. The lack of spectroscopic detail available from PVT spectra has restricted these systems primarily to performing simple gross counting measurements in the past. A common approach to extend the capability of PVT detectors beyond simple “gross-gamma” use is to apply a technique known as energy windowing (EW) to perform rough nuclide identification with limited spectral information. An approach to creating EW algorithms was developed in this work utilizing a specific set of calibration sources and modified EW equations; this algorithm provided a degree of increased identification capability. A simulated real-time emulation of the algorithm utilizing actual port-of-entry RPM data supplied by ORNL provided an extensive proving ground for the algorithm. This algorithm is able to identify four potential threat nuclides and the major NORM source with a high degree of accuracy. High-energy masking, a major detriment of EW algorithms, is reduced by the algorithm's design. - Highlights: • Gross counting algorithms do not produce detailed screenings. • Energy windowing algorithms enhance nuclide identification capability. • Proper use of EW algorithm can identify multiple threat nuclides. • Utilizing specific set of calibration sources is important for nuclide identification

  15. BRAZILIAN NEWS PORTALS CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    Heloiza G. Herckovitz

    2011-02-01

    Full Text Available A content analysis of four Brazilian news media portals found that economic news dominated the top headlines with little attention paid to education, the environment and welfare. Other trends included a focus on local events and national news sources, reliance on few sources, mostly official ones, and a low percentage of news that fitted the concept of newsworthiness (a combination of both social significance and deviance concepts. Other findings of a study of 432 top news stories published by UOL, Estadão, iG and Terra during a 15-day period between February and March 2008 indicate that the top portions of the portals’ front pages carry news that lacks story depth, editorial branding, and multimedia applications. The results suggest that online news portals are in their infancy although Brazil has the largest online population of Latin America. This study hopes to shed light on the gatekeeping process in Brazilian news portals. Brazilian media portals have yet to become a significant editorial force able to provide knowledge about social issues and public affairs in a socially responsible fashione.

  16. Idiopathic noncirrhotic portal hypertension: current perspectives.

    Science.gov (United States)

    Riggio, Oliviero; Gioia, Stefania; Pentassuglio, Ilaria; Nicoletti, Valeria; Valente, Michele; d'Amati, Giulia

    2016-01-01

    The term idiopathic noncirrhotic portal hypertension (INCPH) has been recently proposed to replace terms, such as hepatoportal sclerosis, idiopathic portal hypertension, incomplete septal cirrhosis, and nodular regenerative hyperplasia, used to describe patients with a hepatic presinusoidal cause of portal hypertension of unknown etiology, characterized by features of portal hypertension (esophageal varices, nonmalignant ascites, porto-venous collaterals), splenomegaly, patent portal, and hepatic veins and no clinical and histological signs of cirrhosis. Physicians should learn to look for this condition in a number of clinical settings, including cryptogenic cirrhosis, a disease known to be associated with INCPH, drug administration, and even chronic alterations in liver function tests. Once INCPH is clinically suspected, liver histology becomes mandatory for the correct diagnosis. However, pathologists should be familiar with the histological features of INCPH, especially in cases in which histology is not only requested to exclude liver cirrhosis.

  17. Patient and provider attitudes toward the use of patient portals for the management of chronic disease: a systematic review.

    Science.gov (United States)

    Kruse, Clemens Scott; Argueta, Darcy A; Lopez, Lynsey; Nair, Anju

    2015-02-20

    Patient portals provide patients with the tools to better manage and understand their health status. However, widespread adoption of patient portals faces resistance from patients and providers for a number of reasons, and there is limited evidence evaluating the characteristics of patient portals that received positive remarks from patients and providers. The objectives of this systematic review are to identify the shared characteristics of portals that receive favorable responses from patients and providers and to identify the elements that patients and providers believe need improvement. The authors conducted a systematic search of the CINAHL and PubMed databases to gather data about the use of patient portals in the management of chronic disease. Two reviewers analyzed the articles collected in the search process in order remove irrelevant articles. The authors selected 27 articles to use in the literature review. Results of this systematic review conclude that patient portals show significant improvements in patient self-management of chronic disease and improve the quality of care provided by providers. The most prevalent positive attribute was patient-provider communication, which appeared in 10 of 27 articles (37%). This was noted by both patients and providers. The most prevalent negative perceptions are security (concerns) and user-friendliness, both of which occurred in 11 of 27 articles (41%). The user-friendliness quality was a concern for patients and providers who are not familiar with advanced technology and therefore find it difficult to navigate the patient portal. The high cost of installation and maintenance of a portal system, not surprisingly, deters some providers from implementing such technology into their practice, but this was only mentioned in 3 of the 27 articles (11%). It is possible that the incentives for meaningful use assuage the barrier of cost. This systematic review revealed mixed attitudes from patients and their providers

  18. The Higgs Portal and Cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Assamagan, Ketevi [Brookhaven National Lab. (BNL), Upton, NY (United States); Chen, Chien-Yi [Perimeter Inst. for Theoretical Physics, Waterloo, ON (Canada); Univ. of Victoria, BC (Canada); Chou, John Paul [Rutgers Univ., Piscataway, NJ (United States); Curtin, David [Univ. of Maryland, College Park, MD (United States); Fedderke, Michael A. [Univ. of Chicago, IL (United States); Gershtein, Yuri [Rutgers Univ., Piscataway, NJ (United States); He, Xiao-Gang [Shanghai Jiao Tong Univ. (China); Klute, Markus [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Kozaczuk, Jonathon [TRIUMF, Vancouver, BC (Canada); Kotwal, Ashutosh [Duke Univ., Durham, NC (United States); Lowette, Steven [Vrije Univ., Brussels (Belgium); No, Jose Miguel [Univ. of Sussex, Brighton (United Kingdom); Plehn, Tilman [Heidelberg Univ. (Germany); Qian, Jianming [Univ. of Michigan, Ann Arbor, MI (United States); Ramsey-Musolf, Michael [Univ. of Massachusetts, Amherst, MA (United States); Safonov, Alexei [Texas A & M Univ., College Station, TX (United States); Shelton, Jessie [Univ. of Illinois, Urbana-Champaign, IL (United States); Spannowsky, Michael [Durham Univ. (United Kingdom); Su, Shufang [Univ. of Arizona, Tucson, AZ (United States); Walker, Devin G. E. [Univ. of Washington, Seattle, WA (United States); Willocq, Stephane [Univ. of Massachusetts, Amherst, MA (United States); Winslow, Peter [Univ. of Massachusetts, Amherst, MA (United States)

    2016-04-18

    Higgs portal interactions provide a simple mechanism for addressing two open problems in cosmology: dark matter and the baryon asymmetry. In the latter instance, Higgs portal interactions may contain the ingredients for a strong first-order electroweak phase transition as well as new CP-violating interactions as needed for electroweak baryogenesis. These interactions may also allow for a viable dark matter candidate. We survey the opportunities for probing the Higgs portal as it relates to these questions in cosmology at the LHC and possible future colliders.

  19. An analysis of splenoportographic findings in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Eun Mi; Moon, Sook Ran; Kim, Han Suk [National Medical Center, Seoul (Korea, Republic of); Park, Soo Soung [College of Medicine, Chung Ang University, Seoul (Korea, Republic of)

    1983-12-15

    Splenoportography has been proved as a useful method for the evaluation of circulatory disturbances in portal hypertension. Authors analyzed the various aspects of these disturbance on splenoportography in 22 cases that was performed under the clinical suspicion of portal hypertension during recent 6 years, from May, 1976 to July 1982 at the Department of Radiology, National Medical Center. The results were as follows: 1. Liver cirrhosis was the most frequent cause of intrahepatic obstruction type in portal hypertension (86%). 2. The portal pressure was more than 400 mmH{sub 2}0 in 67% of the cases (range; 300-540 mmH{sub 2}0). 3. In the majority of the cases, the higher the portal pressure was, the more dilated splenic and portal veins were. The diameter of portal vein was more than 15 mm in 79%, more than 21 mm in 47% of the cases (range; 10-26 mm). The diameter of splenic vein was more than 15 mm in 48% of the cases (range; 7-23 mm). Especially the diameter of splenic vein was larger than that of portal vein in 20% of the cases. 4. There was no definite correlation between the development of collateral circulation and the diameter of splenic and portal veins. 5. The filling of collateral circulation was definite sign of portal hypertension, though not regular. In portal hypertension, the collateral circulation was formed via coronary vein (91%), short gastric vein (64%), inferior mesenteric vein (36%). 6. Splenic-hilum time was delayed in 64% of the cases. Intrahepatic portal vein emptying time was more than 6 seconds in all the cases. 7. Most of the cases (91%) could be diagnosed as portal hypertension with vasculogram and hepatogram.

  20. An analysis of splenoportographic findings in portal hypertension

    International Nuclear Information System (INIS)

    Jung, Eun Mi; Moon, Sook Ran; Kim, Han Suk; Park, Soo Soung

    1983-01-01

    Splenoportography has been proved as a useful method for the evaluation of circulatory disturbances in portal hypertension. Authors analyzed the various aspects of these disturbance on splenoportography in 22 cases that was performed under the clinical suspicion of portal hypertension during recent 6 years, from May, 1976 to July 1982 at the Department of Radiology, National Medical Center. The results were as follows: 1. Liver cirrhosis was the most frequent cause of intrahepatic obstruction type in portal hypertension (86%). 2. The portal pressure was more than 400 mmH 2 0 in 67% of the cases (range; 300-540 mmH 2 0). 3. In the majority of the cases, the higher the portal pressure was, the more dilated splenic and portal veins were. The diameter of portal vein was more than 15 mm in 79%, more than 21 mm in 47% of the cases (range; 10-26 mm). The diameter of splenic vein was more than 15 mm in 48% of the cases (range; 7-23 mm). Especially the diameter of splenic vein was larger than that of portal vein in 20% of the cases. 4. There was no definite correlation between the development of collateral circulation and the diameter of splenic and portal veins. 5. The filling of collateral circulation was definite sign of portal hypertension, though not regular. In portal hypertension, the collateral circulation was formed via coronary vein (91%), short gastric vein (64%), inferior mesenteric vein (36%). 6. Splenic-hilum time was delayed in 64% of the cases. Intrahepatic portal vein emptying time was more than 6 seconds in all the cases. 7. Most of the cases (91%) could be diagnosed as portal hypertension with vasculogram and hepatogram

  1. Portal Vein Dopplerflowmetry in healthy sheep according to age

    Directory of Open Access Journals (Sweden)

    Alexandra F. Belotta

    Full Text Available ABSTRACT: Pulsed Doppler ultrasound was used to evaluate portal blood flow, portal velocity and portal congestion index in 24 healthy sheep divided into groups (lambs, yearlings and ewes, according to age. Measurements were performed at the 11th right intercostal space using ideal insonation angle and uniform insonation method. Mean values obtained in each group were compared with one-way ANOVA, followed by Tukey post-hoc test. Portal velocity and portal blood flow were statistically similar between the groups (P>0.05. Mean portal velocity were 17.75; 17.13 and 16.75; while mean portal blood flow were 26.65; 31.04 and 24.32 for lambs, yearlings and ewes, respectively. Portal congestion index was statistically distinct between the groups and values for lambs, yearlings and ewes were 0.009; 0.058 and 0.09, respectively (P<0.01. Statistical differences were observed in portal vein diameter, portal vein area and portal congestion index between the groups, presumably due to influence of weight and not to age.

  2. A Climate Information Portal for Copernicus: a central portal for European climate services?

    Science.gov (United States)

    Juckes, Martin; Swart, Rob; Thysse, Peter; Som de Cerff, Wim; Groot, Annemarie; Bennett, Victoria; Costa, Luis; Lückenkötter, Johannes; Callaghan, Sarah

    2015-04-01

    The FP7 project "Climate Information Portal for Copernicus" (CLIPC) is developing a demonstration portal for the Copernicus Climate Change Service (C3S). This project is one of a suite of FP7 research activities which are administratively independent of Copernicus, focussed on creating the technical and scientific building blocks needed for the service. It is to be expected that at EGU 2015 there will be many presentations describing portals delivering new and innovative ranges of services. It would be unwise to seek to replace all this creative activity with a single portal -- instead CLIPC is designing a portal to make distributed resources more accessible through flexible discovery systems. CLIPC needs to deliver more than a directory of resources: resources need to be presented in common protocols so that users can access multiple datasets. More information about the project objectives is available at www.clipc.eu. The gulf between the climate science communities and the end user communities is a central challenge being addressed in the project. It is important to understand that there is significant diversity and multiple communication barriers within these two sets of communities as well as between them. The CLIPC services must presentation will provide a review of progress towards this ambitious goal, through a discussion of user requirements activities, an overview of the proposed architecture, work on assessing and adjusting model biasses, and a discussion of the climate impact indicators which will be provided through the portal. When looking at the usability of data for the various users, CLIPC will implement a set of services functioning as a "knowledge base" supplying information to users about the data, including definitions of terminology used, quality of datasets, versioning, and user annotations.

  3. The Anatomy of a Grid portal

    International Nuclear Information System (INIS)

    Licari, Daniele; Calzolari, Federico

    2011-01-01

    In this paper we introduce a new way to deal with Grid portals referring to our implementation. L-GRID is a light portal to access the EGEE/EGI Grid infrastructure via Web, allowing users to submit their jobs from a common Web browser in a few minutes, without any knowledge about the Grid infrastructure. It provides the control over the complete lifecycle of a Grid Job, from its submission and status monitoring, to the output retrieval. The system, implemented as client-server architecture, is based on the Globus Grid middleware. The client side application is based on a java applet; the server relies on a Globus User Interface. There is no need of user registration on the server side, and the user needs only his own X.509 personal certificate. The system is user-friendly, secure (it uses SSL protocol, mechanism for dynamic delegation and identity creation in public key infrastructures), highly customizable, open source, and easy to install. The X.509 personal certificate does not get out from the local machine. It allows to reduce the time spent for the job submission, granting at the same time a higher efficiency and a better security level in proxy delegation and management.

  4. The Anatomy of a Grid portal

    Science.gov (United States)

    Licari, Daniele; Calzolari, Federico

    2011-12-01

    In this paper we introduce a new way to deal with Grid portals referring to our implementation. L-GRID is a light portal to access the EGEE/EGI Grid infrastructure via Web, allowing users to submit their jobs from a common Web browser in a few minutes, without any knowledge about the Grid infrastructure. It provides the control over the complete lifecycle of a Grid Job, from its submission and status monitoring, to the output retrieval. The system, implemented as client-server architecture, is based on the Globus Grid middleware. The client side application is based on a java applet; the server relies on a Globus User Interface. There is no need of user registration on the server side, and the user needs only his own X.509 personal certificate. The system is user-friendly, secure (it uses SSL protocol, mechanism for dynamic delegation and identity creation in public key infrastructures), highly customizable, open source, and easy to install. The X.509 personal certificate does not get out from the local machine. It allows to reduce the time spent for the job submission, granting at the same time a higher efficiency and a better security level in proxy delegation and management.

  5. Glucose monitoring technologies - complementary or competitive? Role of continuous glucose monitoring versus flash glucose monitoring versus self-monitoring of blood glucose

    Directory of Open Access Journals (Sweden)

    Jothydev Kesavadev

    2017-01-01

    Full Text Available We have numerous technologies that can help keep a close watch on an individual's glycaemic status and thereby assist in developing successful diabetes management strategies. For more than five decades, self-monitoring of blood glucose (SMBG has remained as the gold standard tool to manage glycaemic status and has gained huge acceptance. Rigorous research further led to the development of more and more advanced technologies such as continuous glucose monitoring and flash glucose monitoring. These novel technologies are more promising in terms of revealing the complete glycaemic picture and even more user-friendly than the already established blood glucosemetres. However, they are yet to achieve remarkable accuracy and performance. There will also be a subgroup of patients who will be using these technologies only occasionally and thus will definitely require SMBG at other times. Again, with regard to the retrospective ones, glucose data can be obtained only once they are downloaded to the system and hence, real-time values will still have to be procured with the help of an SMBG. In future when the accuracy and performance of these newer technologies become equal to that of glucometres, the glucometres might vanish. Until then, all these technologies will definitely go hand-in-hand and supplement each other than competing each other. All the related literature were retrieved from various databases including 'PubMed' and 'Cochrane Database of Systematic Reviews' using specific search terms that were relevant to the topics discussed this manuscript.

  6. Health technology assessment to optimize health technology utilization: using implementation initiatives and monitoring processes.

    Science.gov (United States)

    Frønsdal, Katrine B; Facey, Karen; Klemp, Marianne; Norderhaug, Inger Natvig; Mørland, Berit; Røttingen, John-Arne

    2010-07-01

    The way in which a health technology is used in any particular health system depends on the decisions and actions of a variety of stakeholders, the local culture, and context. In 2009, the HTAi Policy Forum considered how health technology assessment (HTA) could be improved to optimize the use of technologies (in terms of uptake, change in use, or disinvestment) in such complex systems. In scoping, it was agreed to focus on initiatives to implement evidence-based guidance and monitoring activities. A review identified systematic reviews of implementation initiatives and monitoring activities. A two-day deliberative workshop was held to discuss key papers, members' experiences, and collectively address key questions. This consensus paper was developed by email and finalized at a postworkshop meeting. Evidence suggests that the impact and use of HTA could be increased by ensuring timely delivery of relevant reports to clearly determined policy receptor (decision-making) points. To achieve this, the breadth of assessment, implementation initiatives such as incentives and targeted, intelligent dissemination of HTA result, needs to be considered. HTA stakeholders undertake a variety of monitoring activities, which could inform optimal use of a technology. However, the quality of these data varies and is often not submitted to an HTA. Monitoring data should be sufficiently robust so that they can be used in HTA to inform optimal use of technology. Evidence-based implementation initiatives should be developed for HTA, to better inform decision makers at all levels in a health system about the optimal use of technology.

  7. The Gulf of Mexico Coastal Ocean Observing System: A Gulf Science Portal

    Science.gov (United States)

    Howard, M.; Gayanilo, F.; Kobara, S.; Jochens, A. E.

    2013-12-01

    The Gulf of Mexico Coastal Ocean Observing System's (GCOOS) regional science portal (gcoos.org) was designed to aggregate data and model output from distributed providers and to offer these, and derived products, through a single access point in standardized ways to a diverse set of users. The portal evolved under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) program where automated largely-unattended machine-to-machine interoperability has always been a guiding tenet for system design. The web portal has a business unit where membership lists, new items, and reference materials are kept, a data portal where near real-time and historical data are held and served, and a products portal where data are fused into products tailored for specific or general stakeholder groups. The staff includes a system architect who built and maintains the data portal, a GIS expert who built and maintains the current product portal, the executive director who marshals resources to keep news items fresh and data manger who manages most of this. The business portal is built using WordPress which was selected because it appeared to be the easiest content management system for non-web programmers to add content to, maintain and enhance. The data portal is custom built and uses database, PHP, and web services based on Open Geospatial Consortium standards-based Sensor Observation Service (SOS) with Observations and Measurements (O&M) encodings. We employ a standards-based vocabulary, which we helped develop, which is registered at the Marine Metadata Interoperability Ontology Registry and Repository (http://mmisw.org). The registry is currently maintained by one of the authors. Products appearing in the products portal are primarily constructed using ESRI software by a Ph.D. level Geographer. Some products were built with other software, generally by graduate students over the years. We have been sensitive to the private sector when deciding which products to produce. While

  8. Geo-portal as a planning instrument: supporting decision making and fostering market potential of Energy efficiency in buildings

    Science.gov (United States)

    Cuca, Branka; Brumana, Raffaella; Oreni, Daniela; Iannaccone, Giuliana; Sesana, Marta Maria

    2014-03-01

    Steady technological progress has led to a noticeable advancement in disciplines associated with Earth observation. This has enabled information transition regarding changing scenarios, both natural and urban, to occur in (almost) real time. In particular, the need for integration on a local scale with the wider territorial framework has occurred in analysis and monitoring of built environments over the last few decades. The progress of Geographic Information (GI) science has provided significant advancements when it comes to spatial analysis, while the almost free availability of the internet has ensured a fast and constant exchange of geo-information, even for everyday users' requirements. Due to its descriptive and semantic nature, geo-spatial information is capable of providing a complete overview of a certain phenomenon and of predicting the implications within the natural, social and economic context. However, in order to integrate geospatial data into decision making processes, it is necessary to provide a specific context, which is well supported by verified data. This paper investigates the potentials of geo-portals as planning instruments developed to share multi-temporal/multi-scale spatial data, responding to specific end-users' demands in the case of Energy efficiency in Buildings (EeB) across European countries. The case study regards the GeoCluster geo-portal and mapping tool (Project GE2O, FP7), built upon a GeoClustering methodology for mapping of indicators relevant for energy efficiency technologies in the construction sector.

  9. Altered blood-brain barrier permeability in rats with prehepatic portal hypertension turns to normal when portal pressure is lowered

    Science.gov (United States)

    Eizayaga, Francisco; Scorticati, Camila; Prestifilippo, Juan P; Romay, Salvador; Fernandez, Maria A; Castro, José L; Lemberg, Abraham; Perazzo, Juan C

    2006-01-01

    AIM: To study the blood-brain barrier integrity in prehepatic portal hypertensive rats induced by partial portal vein ligation, at 14 and 40 d after ligation when portal pressure is spontaneously normalized. METHODS: Adult male Wistar rats were divided into four groups: Group I: Sham14d , sham operated; Group II: PH14d , portal vein stenosis; (both groups were used 14 days after surgery); Group III: Sham40d, Sham operated and Group IV: PH40d Portal vein stenosis (Groups II and IV used 40 d after surgery). Plasma ammonia, plasma and cerebrospinal fluid protein and liver enzymes concentrations were determined. Trypan and Evans blue dyes, systemically injected, were investigated in hippocampus to study blood-brain barrier integrity. Portal pressure was periodically recorded. RESULTS: Forty days after stricture, portal pressure was normalized, plasma ammonia was moderately high, and both dyes were absent in central nervous system parenchyma. All other parameters were reestablished. When portal pressure was normalized and ammonia level was lowered, but not normal, the altered integrity of blood-brain barrier becomes reestablished. CONCLUSION: The impairment of blood-brain barrier and subsequent normalization could be a mechanism involved in hepatic encephalopathy reversibility. Hemodynamic changes and ammonia could trigger blood-brain barrier alterations and its reestablishment. PMID:16552803

  10. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors

    Directory of Open Access Journals (Sweden)

    Deirdre M Mooney

    2015-10-01

    Full Text Available Heart failure (HF is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  11. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors.

    Science.gov (United States)

    Mooney, Deirdre M; Fung, Erik; Doshi, Rahul N; Shavelle, David M

    2015-01-01

    Heart failure (HF) is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF) can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  12. Enterprise Information Management with Plone Portals

    Directory of Open Access Journals (Sweden)

    Marcello Peixoto Bax

    2009-05-01

    Full Text Available The article shows that it is possible to implement a corporate portal using open source software, in an integrated manner with the proprietary MS Windows environment. As it is the real scenario in the vast majority of businesses and organizations today, a portal that meets these specific requirements is highly representative, mainly because MS Windows integration in the client environment (not in the server is not trivial for an open source portal. The paper shows that, by deploying a portal in this context the company considerably moves forward regarding information management. To show this, the article focuses on the key positive aspects arising from the deployment of a intranet / extranet portal in that context, i.e., MS Windows integration; editing with MS Office or other similar applications; shared editing control (with check-in and check-out; universal web access; and the use of metadata and workflow.

  13. Design of a New Collimation System to Prevent Interference between X-ray Machines and Radiation Portal Monitors

    International Nuclear Information System (INIS)

    Guzzardo, Tyler; Livesay, Jake

    2012-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) developed a new collimation system that allows radiation portal monitors (RPMs) installed near x-ray machines to operate with a negligible false-positive alarm rate. RPMs are usually installed as far as possible from x-ray machines because false alarms are triggered by escaping x-rays; however, constraints at the installation site sometimes make it necessary that RPMs be installed near x-ray machines. Such RPMs are often plagued by high alarm rates resulting from the simultaneous operation of the RPMs and x-ray machines. Limitations on pedestrian flow, x-ray machine orientation, and RPM location often preclude a simple solution for lowering the alarm rate. Adding additional collimation to the x-ray machines to stop the x-rays at the source can reduce the alarm rate without interfering with site operations or adversely affecting the minimum detectable quantity of material (MDQ). A collimation design has been verified by measurements conducted at a RPM installation site and is applicable to all new and existing RPM installations near x-ray machines.

  14. “The Record is Our Work Tool!”—Physicians’ Framing of a Patient Portal in Sweden

    Science.gov (United States)

    2016-01-01

    Background Uppsala County in Sweden launched an eHealth patient portal in 2012, which allows patients to access their medical records over the Internet. However, the launch of the portal was critically debated in the media. The professionals were strongly skeptical, and one reason was possible negative effects on their work environment. This study hence investigates the assumptions and perspectives of physicians to understand their framing of the patient portal in relation to their work environment. Objective The study uses the concept of technological frames to examine how physicians in different specialties make sense of the patient portal in relation to their work environment. Methods A total of 12 semistructured interviews were conducted with physicians from different specialties. Interviews were transcribed and translated. A theoretically informed thematic analysis was performed. Results The thematic analysis revealed 4 main themes: work tool, process, workload, and control. Physicians perceive medical records as their work tool, written for communication within health care only. Considering effects on work environment, the physicians held a negative attitude and expected changes, which would affect their work processes in a negative way. Especially the fact that patients might read their test results before the physician was seen as possibly harmful for patients and as an interference with their established work practices. They expected the occurrence of misunderstandings and needs for additional explanations, which would consequently increase their workload. Other perceptions were that the portal would increase controlling and monitoring of physicians and increase or create a feeling of mistrust from patients. Regarding benefits for the patients, most of the physicians believe there is only little value in the patient portal and that patients would mostly be worried and misunderstand the information provided. Conclusions Supported by the study, we conclude

  15. Portal cholangiopathy: case report

    Directory of Open Access Journals (Sweden)

    Maria Cecilia Almeida Maia

    2014-01-01

    Full Text Available The present report describes the case of a child that after blunt abdominal trauma presented with portal thrombosis followed by progressive splenomegaly and jaundice. Ultrasonography and percutaneous cholangiography revealed biliary dilatation secondary to choledochal stenosis caused by dilated peribiliary veins, characterizing a case of portal biliopathy. The present case report is aimed at presenting an uncommon cause of this condition.

  16. Some thoughts to realignment of PortalU

    International Nuclear Information System (INIS)

    Konstantinidis, Stefanie; Kruse, Fred

    2013-01-01

    Environmental information is the basis for improving the environmental situation in the EU. The challenge poses the tailoring of information to a defined group of interest and not only the technical possibility to retrieve the environmental information. Even though, the technical infrastructure for retrieving public environmental information is the first step. Hence, the clear understanding of the needs of the general public is essential for a successful environmental information portal for the interest group ''general public''. What does this mean referring to the German Environmental Information Portal PortalU? Since the launch of PortalU the focus of the portal is set on making available official environmental information especially on German Federal Republic and Federal States level. Currently, information from web pages represents the greatest amount of information. In contrast, information from environmental data catalogs and further data bases represent a smaller amount of information within PortalU. But quantity itself does not tell anything about the demand of a target group. The experience of the last years has shown that environmental interested citizens use mainly general search engines like Google to find information from public environmental web pages. Thus it would be worth thinking about a realignment of PortalU. The idea of a prospective alignment of PortalU is to concentrate on important environmental information, which is not easily found via Google and other general search engines. This information is mainly provided via environmental data catalogs and possibly further data bases. Some thoughts about the potential form and design of a respectively aligned environmental portal are discussed in the paper. (orig.)

  17. Paper on operation and maintenance experiences on radiation monitoring instrumentation at NAPS

    International Nuclear Information System (INIS)

    Gupta, J.P.; Vinod Kumar; Sen, S.K.; Malhotra, S.

    2005-01-01

    Narora Atomic Power Station (NAPS) is the first standardized Pressurised Heavy Water Reactor in India commissioned in the year 1989. Many new Radiation Monitoring Systems like Portal Monitors and Ventilation Exhaust Activity Monitors were first time introduced at NAPS. All the Personnel Contamination Monitors and Area Radiation Monitors used at NAPS were designed and developed by Electronics Division, BARC. Only the Portal Monitor was supplied by M/S Herfurth, Germany. The paper highlights the operation and maintenance experiences on Radiation Monitoring Instrumentation at NAPS in the last 15 years of operation. The paper also highlights the different problems faced in Radiation Instruments and our suggestions for improvement in their design for their better availability and long term reliability. (author)

  18. Smart homes and home health monitoring technologies for older adults: A systematic review.

    Science.gov (United States)

    Liu, Lili; Stroulia, Eleni; Nikolaidis, Ioanis; Miguel-Cruz, Antonio; Rios Rincon, Adriana

    2016-07-01

    Around the world, populations are aging and there is a growing concern about ways that older adults can maintain their health and well-being while living in their homes. The aim of this paper was to conduct a systematic literature review to determine: (1) the levels of technology readiness among older adults and, (2) evidence for smart homes and home-based health-monitoring technologies that support aging in place for older adults who have complex needs. We identified and analyzed 48 of 1863 relevant papers. Our analyses found that: (1) technology-readiness level for smart homes and home health monitoring technologies is low; (2) the highest level of evidence is 1b (i.e., one randomized controlled trial with a PEDro score ≥6); smart homes and home health monitoring technologies are used to monitor activities of daily living, cognitive decline and mental health, and heart conditions in older adults with complex needs; (3) there is no evidence that smart homes and home health monitoring technologies help address disability prediction and health-related quality of life, or fall prevention; and (4) there is conflicting evidence that smart homes and home health monitoring technologies help address chronic obstructive pulmonary disease. The level of technology readiness for smart homes and home health monitoring technologies is still low. The highest level of evidence found was in a study that supported home health technologies for use in monitoring activities of daily living, cognitive decline, mental health, and heart conditions in older adults with complex needs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Cultura tecnológica e redes sociotécnicas: um estudo sobre o portal da rede municipal de ensino de São Paulo Technological culture and sociotechnical networks: a study of the São Paulo municipal school system web portal

    Directory of Open Access Journals (Sweden)

    Zulmira Medeiros

    2008-04-01

    Full Text Available A realização deste estudo deu-se a partir da hipótese de que as instituições educacionais ou redes de ensino podem utilizar a internet para estabelecer uma nova forma de contato administrativo e pedagógico dentro das suas comunidades escolares. O referencial teórico parte de elementos como mudanças sociais, culturais e tecnológicas para, em seguida, situar em tal contexto o educador e sua apropriação da cultura tecnológica. Ao final, aborda a constituição de redes sociotécnicas no meio educacional, tendo a internet como elemento facilitador. Para isso, trata também de temas como as redes sociais e os portais educacionais. Em campo, buscou-se investigar o processo de constituição de uma rede sociotécnica em uma rede municipal de ensino. Por meio de observações, levantamentos, questionários e entrevistas, realizou-se um estudo de caso, no qual foi possível acompanhar a criação, implantação e utilização de um portal na internet, caracterizado como um novo espaço de comunicação, de interação e de troca de informações entre a comunidade escolar. A investigação concentrou-se na figura do educador e sua percepção acerca desse espaço. Acreditando que a relação entre o homem e a tecnologia envolve um processo de apropriação da cultura tecnológica, que influencia diretamente a sua atuação na sociedade em rede, pôde-se concluir que portais educacionais podem ser utilizados por instituições de ensino, de forma produtiva e colaborativa, entre todos os atores da comunidade educacional, desde que em tal processo se leve em consideração, dentre outros aspectos, a cultura tecnológica dessa comunidade.The point of departure for this study is the hypothesis that educational institutions and school systems can use the Internet to establish a new form of administrative and pedagogical contact within their school communities. The theoretical framework involves elements such as social, cultural, and technological

  20. The challenges of knowledge management portals application and implementation:An Iranian organizations case study

    Directory of Open Access Journals (Sweden)

    Sara Sharifi-Yazdi

    2010-07-01

    Full Text Available This article aims to review, identify and prioritize challenge factors of the implementation of knowledge management portals for Iranian organizations. The study determines several important weakness factors affecting the implications of the knowledge management such as the weakness in organizational strategy, information overcrowd, content management, portals project management, and etc. The study also indicates that the factors have different priorities where managerial factors are in the highest priority and financial factors are in the lowest priority. We also perform factor analysis to summarize seventeen factors into six issues: Financial and information security, Technology and management, Senior management support and strategy, Acceptance, User's motivation and culture, Project management, Change management and training. Knowledge management portal is a brand new concept for Iranian organizations and it is hard to gather information from limited number of organizations or companies for applied knowledge management portals. The results of this study could be useful for knowledge management planners and managers in organizations and clear the prospects to deal with the challenges.

  1. Lunar and Vesta Web Portals

    Science.gov (United States)

    Law, E.; JPL Luna Mapping; Modeling Project Team

    2015-06-01

    The Lunar Mapping and Modeling Project offers Lunar Mapping and Modeling Portal (http://lmmp.nasa.gov) and Vesta Trek Portal (http://vestatrek.jpl.nasa.gov) providing interactive visualization and analysis tools to enable users to access mapped Lunar and Vesta data products.

  2. Preduodenal portal vein: its surgical significance.

    Science.gov (United States)

    Makey, D A; Bowen, J C

    1978-11-01

    Preduodenal portal vein is a rare anatomical variant which may be one of many anomalies in the neonate with duodenal "atresia." Preduodenal portal vein also may be an occasional finding in an adult undergoing biliary, gastric, or pancreatic surgery. Awareness and recognition of the anomaly are essential for the avoidance of injury during such operations. We report here a symptomless patient whose preduodenal portal vein was discovered at cholecystectomy.

  3. Making technology public

    DEFF Research Database (Denmark)

    Winthereik, Brit Ross; Johannsen, Nis; Strand, Dixi Louise

    2008-01-01

    the transformative potential of the portal presentation for reconfiguring relationships between citizens, health care systems, and information and communication technology (ICT). The analysis is guided by Haraway's notion of diffraction. Findings – The analysis demonstrates the particular way in which the user...... secure the future of the technology and organisation behind it. Research limitations/implications – The paper extends the script metaphor beyond a limited designer-technology-user configuration and argues that scripts in the paraphernalia of technologies also can and should be “de......Purpose – Through an analysis of a demonstration video presenting a new national e-health portal, this paper aims to explore the assumptions and limitations of the concept of “script” and suggests a different approach to analysing the moral order of technology design. Design...

  4. Developing patient portals in a fragmented healthcare system.

    Science.gov (United States)

    Otte-Trojel, Terese; de Bont, Antoinette; Aspria, Marcello; Adams, Samantha; Rundall, Thomas G; van de Klundert, Joris; de Mul, Marleen

    2015-10-01

    Use of patient portals may contribute to improved patient health and experiences and better organizational performance. In the Netherlands, patient portals have gained considerable attention in recent years, as evidenced by various policy initiatives and practical efforts directed at developing portals. Due to the fragmented setup of the Dutch healthcare system patient portals that give patients access to information and services from across their providers are developed in inter-organizational collaboration. The objective of this paper is to identify and describe the types of collaborations, or networks, that have been established to develop patient portals in the Netherlands. Understanding the characteristics of these networks as well as the development of their respective portals enables us to assess the enabling and constraining effects of different network types on patient portal initiatives. We used qualitative methods including interview and documents analysis. In a first step, we interviewed eighteen experts and reviewed relevant national policy and strategy documents. Based on this orientation, we selected three networks we deemed to be representative of inter-organizational efforts to develop Dutch patient portals in 2012. In a second step, we interviewed twelve representatives of these patient portal networks and collected documents related to the portals. We applied content analytic techniques to analyze data from the three cases. The three studied networks differed in their number and diversity of actors, the degree to which these actors were mutually dependent, the degree to which network governance was decentralized, and the dynamics of the network structures. We observed that the portals developed in networks displaying the highest degree of these characteristics experienced most difficulties associated with developing patient portals - such as achieving interoperability, successful implementation, regulatory complaisance, and financial

  5. OntoFire: an ontology-based geo-portal for wildfires

    Directory of Open Access Journals (Sweden)

    K. Kalabokidis

    2011-12-01

    Full Text Available With the proliferation of the geospatial technologies on the Internet, the role of geo-portals (i.e. gateways to Spatial Data Infrastructures in the area of wildfires management emerges. However, keyword-based techniques often frustrate users when looking for data of interest in geo-portal environments, while little attention has been paid to shift from the conventional keyword-based to navigation-based mechanisms. The presented OntoFire system is an ontology-based geo-portal about wildfires. Through the proposed navigation mechanisms, the relationships between the data can be discovered, which would otherwise not be possible when using conventional querying techniques alone. End users can use the browsing interface to find resources of interest by using the navigation mechanisms provided. Data providers can use the publishing interface to submit new metadata, modify metadata or removing metadata in/from the catalogue. The proposed approach can improve the discovery of valuable information that is necessary to set priorities for disaster mitigation and prevention strategies. OntoFire aspires to be a focal point of integration and management of a very large amount of information, contributing in this way to the dissemination of knowledge and to the preparedness of the operational stakeholders.

  6. Electronic Health Record Portal Adoption: a cross country analysis.

    Science.gov (United States)

    Tavares, Jorge; Oliveira, Tiago

    2017-07-05

    This study's goal is to understand the factors that drive individuals to adopt Electronic Health Record (EHR) portals and to estimate if there are differences between countries with different healthcare models. We applied a new adoption model using as a starting point the extended Unified Theory of Acceptance and Use of Technology (UTAUT2) by incorporating the Concern for Information Privacy (CFIP) framework. To evaluate the research model we used the partial least squares (PLS) - structural equation modelling (SEM) approach. An online questionnaire was administrated in the United States (US) and Europe (Portugal). We collected 597 valid responses. The statistically significant factors of behavioural intention are performance expectancy ([Formula: see text] total  = 0.285; P expectancy ([Formula: see text] total  = 0.160; P value ([Formula: see text] total  = 0.152; P value are only predictors in the US group. The model explained 53% of the variance in behavioural intention and 36% of the variance in use behaviour. Our study identified critical factors for the adoption of EHR portals and significant differences between the countries. Confidentiality issues do not seem to influence acceptance. The EHR portals usage patterns are significantly higher in US compared to Portugal.

  7. Status of radiation detector and neutron monitor technology

    CERN Document Server

    Kim, Y K; Ha, J H; Han, S H; Hong, S B; Hwang, I K; Lee, W G; Moon, B S; Park, S H; Song, M H

    2002-01-01

    In this report, we describe the current states of the radiation detection technology, detectors for industrial application, and neutron monitors. We also survey the new technologies being applied to this field. The method to detect radiation is the measurement of the observable secondary effect from the interaction between incident radiation and detector material, such as ionization, excitation, fluorescence, and chemical reaction. The radiation detectors can be categorized into gas detectors, scintillation detectors, and semiconductor detectors according to major effects and main applications. This report contains the current status and operational principles of these detectors. The application fields of radiation detectors are industrial measurement system, in-core neutron monitor, medical radiation diagnostic device, nondestructive inspection device, environmental radiation monitoring, cosmic-ray measurement, security system, fundamental science experiment, and radiation measurement standardization. The st...

  8. Liferay Portal Systems Development

    CERN Document Server

    Yuan, Jonas X

    2012-01-01

    This book focuses on teaching by example. Every chapter provides an overview, and then dives right into hands-on examples so you can see and play with the solution in your own environment. This book is for Java developers who don't need any prior experience with Liferay portal. Although Liferay portal makes heavy use of open source frameworks, no prior experience of using these is assumed.

  9. A Data-Centered Collaboration Portal to Support Global Carbon-Flux Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Deborah A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States); Humphrey, Marty [Univ. of Virginia, Charlottesville, VA (United States); Beekwilder, Norm [Univ. of Virginia, Charlottesville, VA (United States); Jackson, Keith [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States); Goode, Monte [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States); van Ingen, Catharine [Microsoft. San Francisco, CA (United States)

    2009-04-07

    Carbon-climate, like other environmental sciences, has been changing. Large-scalesynthesis studies are becoming more common. These synthesis studies are often conducted by science teams that are geographically distributed and on datasets that are global in scale. A broad array of collaboration and data analytics tools are now available that could support these science teams. However, building tools that scientists actually use is hard. Also, moving scientists from an informal collaboration structure to one mediated by technology often exposes inconsistencies in the understanding of the rules of engagement between collaborators. We have developed a scientific collaboration portal, called fluxdata.org, which serves the community of scientists providing and analyzing the global FLUXNET carbon-flux synthesis dataset. Key things we learned or re-learned during our portal development include: minimize the barrier to entry, provide features on a just-in-time basis, development of requirements is an on-going process, provide incentives to change leaders and leverage the opportunity they represent, automate as much as possible, and you can only learn how to make it better if people depend on it enough to give you feedback. In addition, we also learned that splitting the portal roles between scientists and computer scientists improved user adoption and trust. The fluxdata.org portal has now been in operation for ~;;1.5 years and has become central to the FLUXNET synthesis efforts.

  10. Some thoughts to realignment of PortalU

    Energy Technology Data Exchange (ETDEWEB)

    Konstantinidis, Stefanie; Kruse, Fred [Lower Saxony Ministry of Environment and Climate Protection, Hannover (Germany). Coordination Centre PortalU

    2013-07-01

    Environmental information is the basis for improving the environmental situation in the EU. The challenge poses the tailoring of information to a defined group of interest and not only the technical possibility to retrieve the environmental information. Even though, the technical infrastructure for retrieving public environmental information is the first step. Hence, the clear understanding of the needs of the general public is essential for a successful environmental information portal for the interest group ''general public''. What does this mean referring to the German Environmental Information Portal PortalU? Since the launch of PortalU the focus of the portal is set on making available official environmental information especially on German Federal Republic and Federal States level. Currently, information from web pages represents the greatest amount of information. In contrast, information from environmental data catalogs and further data bases represent a smaller amount of information within PortalU. But quantity itself does not tell anything about the demand of a target group. The experience of the last years has shown that environmental interested citizens use mainly general search engines like Google to find information from public environmental web pages. Thus it would be worth thinking about a realignment of PortalU. The idea of a prospective alignment of PortalU is to concentrate on important environmental information, which is not easily found via Google and other general search engines. This information is mainly provided via environmental data catalogs and possibly further data bases. Some thoughts about the potential form and design of a respectively aligned environmental portal are discussed in the paper. (orig.)

  11. Application of online chemistry monitoring programs and technology

    International Nuclear Information System (INIS)

    Perkins, D.; Choi, S.; Haas, C.

    2010-01-01

    To fully understand the impact of chemistry changes, several plant parameters must be considered and reviewed with actual chemistry analyses and compared to plant operating parameters. In some cases, this requires the ability to rapidly correlate plant operational data with laboratory and chemistry data. An effective online monitoring system should be able to: Integrate and extract online data from the plant laboratory and operating information from various plant data sources continuously; Interrogate and extract laboratory data from manually entered data on predefined frequencies; Interact with multiple laboratories in multiple locations; Evaluate data against plant limits (calculated or static) and provide personnel with action level or notification of plant exceeding limits; and, Provide the ability to evaluate against a standard and site specific set of calculations. The nuclear power industry continues to refine and apply new technologies in an effort to notify operators of changes in chemical conditions, calculate complex high temperature results, and monitor system performance. EPRI developed software specifically focused on plant chemistry program optimization using power operation and shutdown data applied with plant equipment. This software evolved into the family of software referred to as EPRI ChemWorks™ applications. As technology changed and improved, the application of online monitoring was essential for plant personnel working offsite. These changes in technology prompted EPRI to the development of SMART ChemWorks™ using the EPRI ChemWorks™ plant chemistry simulator and MULTEQ applications as the backbone for these simulations and calculations. SMART ChemWorks™ is an online monitoring system that queries plant databases and continuously monitors plant and chemistry parameters. The system uses a real-time intelligence engine to perform virtual sensing, identify normal and off-normal conditions and compare in-line instrument output to grab

  12. Pathophysiology of Portal Hypertension and Its Clinical Links

    Science.gov (United States)

    Seo, Yeon Seok; Shah, Vijay H

    2011-01-01

    Portal hypertension is a major cause of morbidity and mortality in patients with liver cirrhosis. Intrahepatic vascular resistance due to architectural distortion and intrahepatic vasoconstriction, increased portal blood flow due to splanchnic vasodilatation, and development of collateral circulation have been considered as major factors for the development of portal hypertension. Recently, sinusoidal remodeling and angiogenesis have been focused as potential etiologic factors and various researchers have tried to improve portal hypertension by modulating these new targets. This article reviews potential new treatments in the context of portal hypertension pathophysiology concepts. PMID:25755320

  13. A View on Electronic Learning Portals

    OpenAIRE

    Zavaraqi, Rasoul

    2009-01-01

    Portals are less than a decade old. They have come to cover are areas of electronic services, including electronic learning. With their efficient communication and information capabilities, these portals are capable of realizing novel learning concepts such as structuralism, active and cooperative learning. The present paper endeavors to discuss the latest understanding, theories and concepts regarding E-learning portals and to review the issues and steps that should be considered in designin...

  14. Transjugular Intrahepatic Portosystemic Shunt for Portal Hypertension in Hepatocellular Carcinoma with Portal Vein Tumor Thrombus.

    Science.gov (United States)

    Qiu, Bin; Li, Kai; Dong, Xiaoqun; Liu, Fu-Quan

    2017-09-01

    In patients with hepatocellular carcinoma (HCC), limited therapeutic options are available for portal hypertension resulted from portal vein tumor thrombus (PVTT). We aimed to determine safety and efficacy of TIPS for treatment of symptomatic portal hypertension in HCC with PVTT. We evaluated clinical characteristics of 95 patients with HCC and PVTT out of 992 patients who underwent TIPS. The primary endpoints included success rate, procedural mortality, serious complications, decrease in portosystemic pressure gradient, and symptom relief. The secondary endpoints included recurrence of portal hypertension, overall survival, adverse events related to treatments for HCC, and quality of life measured by Karnofsky Performance Status Scale (KPS). Success rate of TIPS was 95.8% (91/95), with procedural mortality of 1.1%. Serious complications related to TIPS procedure occurred in 2.1% (2/95) of patients. The symptoms of portal hypertension were well relieved. Variceal bleeding was successfully controlled and terminated in 100% of patients, with a recurrence rate of 39.2% in 12 months. Refractory ascites/hydrothorax was controlled partially or completely in 92.9% of patients during 1 month after TIPS, with a recurrence rate of 17.9% in 12 months. Survival rate at 6, 12, 24, and 36 months was 75.8, 52.7, 26.4, and 3.3%, respectively. No unexpected adverse event related to treatments for HCC was observed. The KPS score was 49 ± 4.5 and 63 ± 4.7 before and 1 month after TIPS, respectively (p portal hypertension in HCC with PVTT.

  15. Technological advances in perioperative monitoring: Current concepts and clinical perspectives.

    Science.gov (United States)

    Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar

    2015-01-01

    Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any.

  16. Distal technologies and type 1 diabetes management.

    Science.gov (United States)

    Duke, Danny C; Barry, Samantha; Wagner, David V; Speight, Jane; Choudhary, Pratik; Harris, Michael A

    2018-02-01

    Type 1 diabetes requires intensive self-management to avoid acute and long-term health complications. In the past two decades, substantial advances in technology have enabled more effective and convenient self-management of type 1 diabetes. Although proximal technologies (eg, insulin pumps, continuous glucose monitors, closed-loop and artificial pancreas systems) have been the subject of frequent systematic and narrative reviews, distal technologies have received scant attention. Distal technologies refer to electronic systems designed to provide a service remotely and include heterogeneous systems such as telehealth, mobile health applications, game-based support, social platforms, and patient portals. In this Review, we summarise the empirical literature to provide current information about the effectiveness of available distal technologies to improve type 1 diabetes management. We also discuss privacy, ethics, and regulatory considerations, issues of global adoption, knowledge gaps in distal technology, and recommendations for future directions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Clinician Perspectives on an Electronic Portal to Improve Communication with Patients and Families in the Intensive Care Unit.

    Science.gov (United States)

    Bell, Sigall K; Roche, Stephanie D; Johansson, Anna C; O'Reilly, Kristin P; Lee, Barbara S; Sands, Kenneth E; Talmor, Daniel S; Brown, Samuel M

    2016-12-01

    Communication in the intensive care unit (ICU) often falls short of patient and family needs, putting them at risk for significant physical and emotional harm. As electronic patient portals rapidly evolve, one designed specifically for the ICU might potentially enhance communication among patients, family members, and clinicians; however, the views of frontline ICU staff on such technology are unknown. To identify clinician perspectives on the current state of communication among patients, families, and clinicians in the ICU, and assess their views on whether and how an electronic portal may address existing communication deficits and improve care. Three focus groups comprised altogether of 26 clinicians from 6 ICUs, representing several disciplines in an academic medical center in Boston, Massachusetts. Transcripts were analyzed inductively for major themes using grounded theory. We identified seven themes reflecting clinician perspectives on communication challenges and desired portal functionality: (1) comprehension and literacy; (2) results and updates; (3) patient and family preferences; (4) interclinician communication; (5) family informational needs; (6) the ICU as an unfamiliar environment; and (7) enhancing humanism through technology. Each theme included current gaps in practice, potential benefits and concerns related to an ICU communication portal, and participant recommendations. Benefits included enhanced education, patient/family engagement, and clinician workflow. Challenges included the stress and uncertainty of ICU care, fear of technology replacing human connection, existing interclinician communication failures, and the tension between informing families without overwhelming them. Overall, clinicians were cautiously supportive of an electronic portal to enhance communication in the ICU and made several specific recommendations for design and implementation. As new technologies expand opportunities for greater transparency and participation in

  18. [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

    Science.gov (United States)

    Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C

    2018-06-01

    An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as

  19. Remote monitoring technologies for the prevention of metabolic syndrome: the Diabetes and Technology for Increased Activity (DaTA) study.

    Science.gov (United States)

    Stuckey, Melanie; Fulkerson, Robyn; Read, Emily; Russell-Minda, Elizabeth; Munoz, Claudio; Kleinstiver, Peter; Petrella, Robert

    2011-07-01

    Remote monitoring technologies are ideally suited for rural communities with limited access to health care. In an 8-week pilot study, we examined the feasibility of implementing and conducting a technology-intensive intervention in an underserviced rural setting. Our goal was to test the utility of self-monitoring technologies, physical activity, and education as tools to manage health indicators for the development of the cardiovascular complications (CVCs) of type 2 diabetes. The Diabetes and Technology for Increased Activity study was an open single-center study conducted in a community-based research setting. All 24 participants were provided with a Blackberry™ Smartphone, blood pressure monitor, glucometer, and pedometer. Smartphones transmitted measurements and survey results to the database, interfaced participants with the clinical team, and allowed for self-monitoring. Outcomes were improved body composition, improved markers of CVC risk factors, increased daily exercise, and interest in or awareness of lifestyle changes that impact health outcomes. Participants had excellent compliance for measurements, as self-monitoring provided a sense of security that improved from week 4 to week 8. Our team gained substantial insight into the operational requirements of technology-facilitated health care, including redefined hours of service; data reporting, management, and access protocols; and the utility of real-time clinical measures by remote monitoring. We developed an understanding of knowledge translation strategies as well as successful motivational and educational tools. Importantly, remote monitoring technology was found to be feasible and accepted in a rural setting. © 2011 Diabetes Technology Society.

  20. Management of small hepatocellular carcinoma in cirrhosis: Focus on portal hypertension

    Science.gov (United States)

    Hernandez-Gea, Virginia; Turon, Fanny; Berzigotti, Annalisa; Villanueva, Augusto

    2013-01-01

    The incidence of hepatocellular carcinoma (HCC) is rising worldwide being currently the fifth most common cancer and third cause of cancer-related mortality. Early detection of HCC through surveillance programs have enabled the identification of small nodules with higher frequency, and nowadays account for 10%-15% of patients diagnosed in the West and almost 30% in Japan. Patients with small HCC can be candidates for potential curative treatments: liver transplantation, surgical resection and percutaneous ablation, depending on the presence of portal hypertension and co-morbidities. This review will analyze recent advancements in the clinical management of these individuals, focusing on issues related to the role of portal hypertension, the debate between resection and ablative therapies and the future impact of molecular technologies. PMID:23482437

  1. Technology of remote monitoring for nuclear activity monitoring

    International Nuclear Information System (INIS)

    Kwack, Ehn Ho; Kim, Jong Soo; Yoon, Wan Ki; Park, Sung Sik; Na, Won Woo; An, Jin Soo; Cha, Hong Ryul; Kim, Jung Soo

    2000-05-01

    In a view of safeguards monitoring at nuclear facilities, the monitoring is changing to remote method so that this report is described to remote monitoring(RM) applying on commercial NPP in Korea. To enhance IAEA safeguards efficiency and effectiveness, IAEA is taking into account of remote monitoring system(RMS) and testing as a field trial. IRMP(International Remote Monitoring Project) in participating many nations for development of RMS is proceeding their project such as technical exchange and research etc. In case of our country are carrying out the research relevant RM since acceptance RMS at 7th ROK-IAEA safeguards implementation review meeting. With a view to enhancement the RMS, installation location and element technology of the RM equipment are evaluated in a view of safeguards in Korea LWRs, and proposed a procedure for national inspection application through remote data evaluation from Younggwang-3 NPP. These results are large valuable to use of national inspection at time point extending installation to all Korea PWR NPP. In case of CANDU, neutron, gamma measurement and basic concept of network using optical fiber scintillating detector as remote verification method for dry storage canister are described. Also RM basic design of spent fuel transfer campaign is described that unattended RM without inspector instead of performing in participating together with IAEA and national inspector. The transfer campaign means the spent fuel storage pond to dry storage canister for about two months every year. Therefore, positively participation of IAEA strength safeguards project will be increased transparency for our nuclear activity as well as contributed to national relevant industry

  2. Technology of remote monitoring for nuclear activity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kwack, Ehn Ho; Kim, Jong Soo; Yoon, Wan Ki; Park, Sung Sik; Na, Won Woo; An, Jin Soo; Cha, Hong Ryul; Kim, Jung Soo

    2000-05-01

    In a view of safeguards monitoring at nuclear facilities, the monitoring is changing to remote method so that this report is described to remote monitoring(RM) applying on commercial NPP in Korea. To enhance IAEA safeguards efficiency and effectiveness, IAEA is taking into account of remote monitoring system(RMS) and testing as a field trial. IRMP(International Remote Monitoring Project) in participating many nations for development of RMS is proceeding their project such as technical exchange and research etc. In case of our country are carrying out the research relevant RM since acceptance RMS at 7th ROK-IAEA safeguards implementation review meeting. With a view to enhancement the RMS, installation location and element technology of the RM equipment are evaluated in a view of safeguards in Korea LWRs, and proposed a procedure for national inspection application through remote data evaluation from Younggwang-3 NPP. These results are large valuable to use of national inspection at time point extending installation to all Korea PWR NPP. In case of CANDU, neutron, gamma measurement and basic concept of network using optical fiber scintillating detector as remote verification method for dry storage canister are described. Also RM basic design of spent fuel transfer campaign is described that unattended RM without inspector instead of performing in participating together with IAEA and national inspector. The transfer campaign means the spent fuel storage pond to dry storage canister for about two months every year. Therefore, positively participation of IAEA strength safeguards project will be increased transparency for our nuclear activity as well as contributed to national relevant industry.

  3. Portal dosimetry in wedged beams

    NARCIS (Netherlands)

    Spreeuw, Hanno; Rozendaal, Roel; Camargo, Priscilla; Mans, Anton; Wendling, Markus; Olaciregui-Ruiz, Igor; Sonke, Jan-Jakob; van Herk, Marcel; Mijnheer, Ben

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the

  4. Benign hepatic portal venous gas following caustic ingestion

    International Nuclear Information System (INIS)

    Lewin, Maite; Tubiana, Jean-Michel; Pocard, Marc; Caplin, Scott; Parc, Rolland; Blain, Antoine

    2002-01-01

    Hepatic portal vein gas has been documented in numerous conditions and is traditionally regarded as a poor prognostic sign. There are, however, several reports of portal vein gas with a benign course. We report the first case of transient hepatic portal vein gas secondary to the ingestion of a caustic substance. The literature of hepatic portal vein gas in benign disease is reviewed. (orig.)

  5. Application of Equipment Monitoring Technology in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kang, H. T.; Lee, J. K.; Lee, K. D.; Jo, S. H.

    2012-01-01

    The major goal of nuclear power industries during the past 10 years is to increase reliability and utility capacity factor. As the capacitor factor, however, crept upward. it became harder to attain next percentage of improvement. Therefore other innovative technologies are required. By the technologies applied to the fossil power plants, equipment health monitoring was performed on equipment to maintain it in operable condition and contributed on improving their reliability a lot. But the equipment monitoring may be limited to the observation of current system states in nuclear power plant. Monitoring of current system states is being augmented with prediction of future operating states and predictive diagnosis of future failure states. Such predictive diagnosis is motivated by the need for nuclear power plants to optimize equipment performance and reduce costs and unscheduled downtime. This paper reviews the application of techniques that focus on improving reliability in nuclear power plant by monitoring and predicting equipment health and suggests how possible to support on-line monitoring

  6. Patient portals - An online tool for your health

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000880.htm Patient portals - an online tool for your health To ... is private and secure. What is in a Patient Portal? With a patient portal, you can: Make ...

  7. Demonstration of innovative monitoring technologies at the Savannah River Integrated Demonstration Site

    Energy Technology Data Exchange (ETDEWEB)

    Rossabi, J. [Westinghouse Savannah River Co., Aiken, SC (United States); Jenkins, R.A.; Wise, M.B. [Oak Ridge National Lab., TN (United States)] [and others

    1993-12-31

    The Department of Energy`s Office of Technology Development initiated an Integrated Demonstration Program at the Savannah River Site in 1989. The objective of this program is to develop, demonstrate, and evaluate innovative technologies that can improve present-day environmental restoration methods. The Integrated Demonstration Program at SRS is entitled ``Cleanup of Organics in Soils and Groundwater at Non-Arid Sites.`` New technologies in the areas of drilling, characterization, monitoring, and remediation are being demonstrated and evaluated for their technical performance and cost effectiveness in comparison with baseline technologies. Present site characterization and monitoring methods are costly, time-consuming, overly invasive, and often imprecise. Better technologies are required to accurately describe the subsurface geophysical and geochemical features of a site and the nature and extent of contamination. More efficient, nonintrusive characterization and monitoring techniques are necessary for understanding and predicting subsurface transport. More reliable procedures are also needed for interpreting monitoring and characterization data. Site characterization and monitoring are key elements in preventing, identifying, and restoring contaminated sites. The remediation of a site cannot be determined without characterization data, and monitoring may be required for 30 years after site closure.

  8. Demonstration of innovative monitoring technologies at the Savannah River Integrated Demonstration Site

    International Nuclear Information System (INIS)

    Rossabi, J.; Jenkins, R.A.; Wise, M.B.

    1993-01-01

    The Department of Energy's Office of Technology Development initiated an Integrated Demonstration Program at the Savannah River Site in 1989. The objective of this program is to develop, demonstrate, and evaluate innovative technologies that can improve present-day environmental restoration methods. The Integrated Demonstration Program at SRS is entitled ''Cleanup of Organics in Soils and Groundwater at Non-Arid Sites.'' New technologies in the areas of drilling, characterization, monitoring, and remediation are being demonstrated and evaluated for their technical performance and cost effectiveness in comparison with baseline technologies. Present site characterization and monitoring methods are costly, time-consuming, overly invasive, and often imprecise. Better technologies are required to accurately describe the subsurface geophysical and geochemical features of a site and the nature and extent of contamination. More efficient, nonintrusive characterization and monitoring techniques are necessary for understanding and predicting subsurface transport. More reliable procedures are also needed for interpreting monitoring and characterization data. Site characterization and monitoring are key elements in preventing, identifying, and restoring contaminated sites. The remediation of a site cannot be determined without characterization data, and monitoring may be required for 30 years after site closure

  9. Differences in Access to and Preferences for Using Patient Portals and Other eHealth Technologies Based on Race, Ethnicity, and Age: A Database and Survey Study of Seniors in a Large Health Plan

    Science.gov (United States)

    Hornbrook, Mark C

    2016-01-01

    portal to send messages, view lab test results, or order prescription refills. Across all age groups, non-Hispanic whites and Chinese seniors were significantly more likely than black, Latino, and Filipino seniors to be registered and to have performed these actions. The survey found that black, Latino, and Filipino seniors and those 75 years old and older were significantly less likely to own digital devices (eg, computers, smartphones), use the Internet and email, and be able and willing to use digital technology to perform health care-related tasks, including obtaining health information, than non-Hispanic whites, Chinese, and younger seniors (aged 65-69), respectively. The preference for using non-digital modalities persisted even among Internet users. Conclusions Health plans, government agencies, and other organizations that serve diverse groups of seniors should include social determinants such as race/ethnicity and age when monitoring trends in eHealth to ensure that eHealth disparities do not induce greater health status and health care disparities between more privileged and less privileged groups. PMID:26944212

  10. Development of conformal respirator monitoring technology

    International Nuclear Information System (INIS)

    Shonka, J.J.; Weismann, J.J.; Logan, R.J.

    1997-04-01

    This report summarizes the results of a Small Business Innovative Research Phase II project to develop a modular, surface conforming respirator monitor to improve upon the manual survey techniques presently used by the nuclear industry. Research was performed with plastic scintillator and gas proportional modules in an effort to find the most conducive geometry for a surface conformal, position sensitive monitor. The respirator monitor prototype developed is a computer controlled, position-sensitive detection system employing 56 modular proportional counters mounted in molds conforming to the inner and outer surfaces of a commonly used respirator (Scott Model 801450-40). The molds are housed in separate enclosures and hinged to create a open-quotes waffle-ironclose quotes effect so that the closed monitor will simultaneously survey both surfaces of the respirator. The proportional counter prototype was also designed to incorporate Shonka Research Associates previously developed charge-division electronics. This research provided valuable experience into pixellated position sensitive detection systems. The technology developed can be adapted to other monitoring applications where there is a need for deployment of many traditional radiation detectors

  11. Combined Rex-bypass shunt with pericardial devascularization alleviated prehepatic portal hypertension caused by cavernomatous transformation of portal vein.

    Science.gov (United States)

    Wang, Ruo-Yi; Wang, Jun-Feng; Liu, Qian; Ma, Nan; Chen, Wei-Xiu; Li, Jin-Liang

    2017-09-01

    To evaluate the effects of combined Rex-bypass shunt and pericardial devascularization on prehepatic portal hypertension secondary to cavernomatous transformation of portal vein (CTPV). Forty-two patients aged from 3 years to 49 years (divided into 3 groups), 26 cases male and 16 female, with prehepatic vascular hepertention were treated with Rex-bypass shunt combined with pericardial devascularization. In each patient, preoperative assessment included ultrasound and computed tomographic angiography of the portal vein and blood analysis. The procedure was Rex-bypass shunt (with or without graft), and patients with moderate or severe gastroesophageal varices required additional paraesophagogastric devascularization. Splenectomy or subtotal splenectomy was performed if combined hypersplenism co-existed. All data were analyzed retrospectively. No intraoperative death occurred, blood routine analysis improved (P portal vein (LPV) significantly increased, the esophageal and gastric varices significantly relieved in 34 patients (P portal hypertension caused by CTPV.

  12. GEO portal

    Data.gov (United States)

    US Agency for International Development — The USAID GeoPortal is a new application that groups web-based capabilities for on-demand discovery of and access to geospatial content, services, expertise, and...

  13. The influence of TripAdvisor portal on hotel bussines in Serbia

    Directory of Open Access Journals (Sweden)

    Čačić Krunoslav

    2013-01-01

    Full Text Available Numerous researches have shown the existence of influence of specialized Web 2.0 portals on hotel business. One of most famous portals of that kind is TripAdvisor. The goal of this work is to determine the degree and mode of representation of hotels in Serbia on TripAdvisor portal. The results of the conducted research show that in past years the number of hotels from Serbia represented on this portal has increased significantly. At the end of 2012 there have been registered 3.288 comments which evaluated the service quality of 165 hotels from Serbia. The average vote, on five-degree scale, calculated at the level of all represented hotels at the end of 2012 was 3,92. Considering that Belgrade represents the primarily business, administrative and touristic center of Serbia, on the Belgrade's hotels specimen there has been analyzed the connection between business performances of hotels expressed through indicator TREVPAR and their image on TripAdvisor expressed through average vote determined based on user's comments, as well as in relation with TripAdvisor Popularity Index (TPI. The results show the high degree of correlation between analyzed features on the specimen of Belgrade's hotels, in range of hotels of second (4* and third category (3*. Having in mind the results of conducted research it is obvious that the hotels managers from Serbia should adopt and implement the corresponding procedures of monitoring and adequate reactions on contents on TripAdvisor, considering their influence on behavior of modern consumer in hotels.

  14. WLCG Operations portal demo tutorial

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This is a navigation through http://wlcg-ops.web.cern.ch/ the Worldwide LHC Computing Grid (WLCG) Operations' portal. In this portal you will find documentation and information about WLCG Operation activities for: System Administrators at the WLCG sites LHC Experiments Operation coordination people, including Task Forces and Working Groups

  15. Unexpected disappearance of portal cavernoma on long-term anticoagulation.

    Science.gov (United States)

    Silva-Junior, Gilberto; Turon, Fanny; Hernandez-Gea, Virginia; Darnell, Anna; García-Criado, Ángeles; García-Pagán, Juan Carlos

    2014-08-01

    Idiopathic non-cirrhotic portal hypertension is a rare disease of unknown etiology. Patients with idiopathic non-cirrhotic portal hypertension have an increased risk of developing portal vein thrombosis and this is especially prevalent when HIV is also present. We describe a unique case of a patient with idiopathic non-cirrhotic portal hypertension associated to HIV, who developed acute portal vein thrombosis that despite anticoagulation transformed in portal cavernoma and disappeared completely after five years of follow-up on continuous anticoagulation. Copyright © 2014 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  16. Heat stress monitoring system. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-11-01

    The US Department of Energy's (DOE) nuclear facility decontamination and decommissioning (D and D) program involves the need to decontaminate and decommission buildings expeditiously and cost-effectively. Simultaneously, the health and safety of personnel involved in the D and D activities is of primary concern. Often, D and D workers must perform duties in inclement weather, and because they also frequently work in contaminated areas, they must wear personal protective clothing and/or respirators. Monitoring the health status of workers under these conditions is an important component of ensuring their safety. The MiniMitter VitalSense Telemetry System's heat stress monitoring system (HSMS) is designed to monitor the vital signs of individual workers as they perform work in conditions that might be conducive to heat exhaustion or heat stress. The HSMS provides real-time data on the physiological condition of workers which can be monitored to prevent heat stress or other adverse health situations. This system is particularly useful when workers are wearing personal protective clothing or respirators that make visual observation of their condition more difficult. The MiniMitter VitalSense Telemetry System can monitor up to four channels (e.g., heart rate, body activity, ear canal, and skin temperature) and ten workers from a single supervisory station. The monitors are interfaced with a portable computer that updates and records information on individual workers. This innovative technology, even though it costs more, is an attractive alternative to the traditional (baseline) technology, which measures environmental statistics and predicts the average worker's reaction to those environmental conditions without taking the physical condition of the individual worker into consideration. Although use of the improved technology might be justified purely on the basis of improved safety, it has the potential to pay for itself by reducing worker time lost caused by heat

  17. User Experience Design in Professional Map-Based Geo-Portals

    Directory of Open Access Journals (Sweden)

    Bastian Zimmer

    2013-10-01

    Full Text Available We have recently been witnessing the growing establishment of map-centered web-based geo-portals on national, regional and local levels. However, a particular issue with these geo-portals is that each instance has been implemented in different ways in terms of design, usability, functionality, interaction possibilities, map size and symbologies. In this paper, we try to tackle these shortcomings by analyzing and formalizing the requirements for map-based geo-portals in a user experience based approach. First, we propose a holistic definition the term of a “geo-portal”. Then, we present our approach to user experience design for map-based geo-portals by defining the functional requirements of a geo-portal, by analyzing previous geo-portal developments, by distilling the results of our empirical user study to perform practically-oriented user requirements, and finally by establishing a set of user experience design guidelines for the creation of map-based geo-portals. These design guidelines have been extracted for each of the main components of a geo-portal, i.e., the map, the search dialogue, the presentation of the search results, symbologies, and other aspects. These guidelines shall constitute the basis for future geo-portal developments to achieve standardization in the user-experience design of map-based geo-portals.

  18. Percutaneous transsplenic catheterization of portal vein: technique and clinical application

    International Nuclear Information System (INIS)

    Zhu Kangshun; Huang Mingsheng; Pang Pengfei; Zhou Bin; Xu Changmo; Qian Jiesheng; Li Zhengran; Jiang Zaibo; Shan Hong

    2010-01-01

    Objective: To evaluate the feasibility of percutaneous transsplenic portal vein catheterization (PTSPC). Methods: Thirty patients with portal hypertension underwent gastroesophageal variceal embolization via PTSPC route, 2 of which simultaneously underwent portal vein stenting. This study included the patients with portal venous obstruction (tumor embolus or thrombus) or the patients with serious liver atrophy caused by liver cirrhosis. The patients who had severe coagulation insufficiency (with prothrombin time > 20 s) were excluded. Of the 30 patients, 17 had primary hepatocellular carcinoma with main portal venous tumor embolus, 13 had cirrhosis with severe liver atrophy and (or)slight or moderate ascite. Before this study, all of 30 patients had a history of variceal bleeding, and 16 patients had a normal coagulation level, 10 patients had a mildly prolonged prothrombin time (14-17 s), 4 patients had a moderately prolonged prothrombin time (18-20 s). All of 30 patients underwent upper abdomen CT enhanced scanning before this procedure, and the site, direction, and depth of splenic vein branch puncture were decided by CT images. The technology of PTSPC, procedure-related complications, and its clinical application were retrospectively analyzed. Results: PTSPC was performed successfully in 28 of 30 patients. Two cases failed because of a small intrasplenic vein. Procedure-related complications occurred in 6 patients (20.0%), which had decrease of hemoglobin concentration (15-50 g/L). Four of them needed blood transfusion. In the six patients, one patient (3.3%) with abdominal cavity hemorrhage had a serious drop of blood pressure 2 hours after procedure, whose clinical symptoms were relieved after four units of packed RBC and a great quantity of fluid were transfused. Twenty-eight patients whose PTSPC were successfully performed underwent variceal embolization, 2 of them were placed with portal vein covered stents. During a median follow-up period of 6 months

  19. Portal Still Alive and Portal 2: Lessons from Critical Narrative Gaming Pedagogy

    OpenAIRE

    Yamasaki, Lisa Josefina

    2016-01-01

    Due to the increasing popularity of video games in mass media culture, I will be investigating one particular video game series, Portal: Still Alive and Portal 2, and the manner by which players learn from them. After observing that most instructors use these games in physics and math classes, I want to expand more on the way that video games enact a new story-telling feature through experiential means, which also serves a pedagogical function. I assert that players learn from games through...

  20. False-positive image of portal thrombosis with MRI: portal hypertension as a pitfall. Observation in a Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Davy-Miallou, C.; Bousquet, J.C.; Bellin, M.F.; Guinet, C.; Grellet, J.

    1990-01-01

    This observation illustrates how difficult it is to interpret the intravascular signal observed with MRI in cases of portal hypertension. A signal occupying the entire lumen of the portal trunk and branches can be seen, which is constantly observed in the axial as well as coronal planes in the 3 series studied. It is hypointense relative to the liver on T1-weighted images, hyperintense on T2-weighted images: this appearance therefore perfectly mimicks portal thrombosis. Ultrasound combined with pulsed Doppler demonstrates the stagnant blood within the patent portal system. This kind of artifact, which is produced by a very slow flow or even by the standstill of flow, is much more difficult to recognize than the common flow artifacts; the criteria put forward by various authors to distinguish between artifacts and thrombosis are of no avail in this case. Examinations must able to confirm or rule out portal thrombosis in the case of portal hypertension with deceleration of flow. In practice, ultrasound studies, combined with pulsed Doppler in the best cases, is therefore indicated as a first-intension technique [fr

  1. Students attendance monitoring using near field communication technology

    OpenAIRE

    Stakėnas, Tautvydas

    2017-01-01

    Today, near field communication technology (NFC) is one of the most popular automatic identification technologies. There is a lot of research and development in this area trying to make as much use of this technology as possible, and in coming years many new applications and research areas will continue to appear. In this paper the author examines NFC technology application for student’s attendance monitoring. In the first part of the thesis NFC uses, application methods and security levels a...

  2. Splanchnic-aortic inflammatory axis in experimental portal hypertension

    Science.gov (United States)

    Aller, Maria-Angeles; de las Heras, Natalia; Nava, Maria-Paz; Regadera, Javier; Arias, Jaime; Lahera, Vicente

    2013-01-01

    Splanchnic and systemic low-grade inflammation has been proposed to be a consequence of long-term prehepatic portal hypertension. This experimental model causes minimal alternations in the liver, thus making a more selective study possible for the pathological changes characteristic of prehepatic portal hypertension. Low-grade splanchnic inflammation after long-term triple partial portal vein ligation could be associated with liver steatosis and portal hypertensive intestinal vasculopathy. In fact, we have previously shown that prehepatic portal hypertension in the rat induces liver steatosis and changes in lipid and carbohydrate metabolism similar to those produced in chronic inflammatory conditions described in metabolic syndrome in humans. Dysbiosis and bacterial translocation in this experimental model suggest the existence of a portal hypertensive intestinal microbiome implicated in both the splanchnic and systemic alterations related to prehepatic portal hypertension. Among the systemic impairments, aortopathy characterized by oxidative stress, increased levels of proinflammatory cytokines and profibrogenic mediators stand out. In this experimental model of long-term triple portal vein ligated-rats, the abdominal aortic proinflammatory response could be attributed to oxidative stress. Thus, the increased aortic reduced-nicotinamide-adenine dinucleotide phosphate [NAD(P)H] oxidase activity could be associated with reactive oxygen species production and promote aortic inflammation. Also, oxidative stress mediated by NAD(P)H oxidase has been associated with risk factors for inflammation and atherosclerosis. The splanchnic and systemic pathology that is produced in the long term after triple partial portal vein ligation in the rat reinforces the validity of this experimental model to study the chronic low-grade inflammatory response induced by prehepatic portal hypertension. PMID:24307792

  3. Ultrasonography for Noninvasive Assessment of Portal Hypertension.

    Science.gov (United States)

    Maruyama, Hitoshi; Yokosuka, Osamu

    2017-07-15

    Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.

  4. Portal in the power sector - it is vision or reality?

    International Nuclear Information System (INIS)

    Hornak, L.

    2004-01-01

    The goal of the presentation is to introduce the portal solutions, to describe the types, characteristic features and abilities of the portal and to define required attributes of the portal in the power segment. The author will try to answer the questions whether such portal exists at the present time, what is needed in order to implement the portal and how to do the portal maintenance and management

  5. [A wireless mobile monitoring system based on bluetooth technology].

    Science.gov (United States)

    Sun, Shou-jun; Wu, Kai; Wu, Xiao-Ming

    2006-09-01

    This paper presents a wireless mobile monitoring system based on Bluetooth technology. This system realizes the remote mobile monitoring of multiple physiological parameters, and has the characters of easy use, low cost, good reliability and strong capability of anti-jamming.

  6. Environmental radiation monitoring technology: Capabilities and needs

    International Nuclear Information System (INIS)

    Hofstetter, K.J.

    1994-01-01

    Radiation monitoring in the Savannah River Site (SRS) environment is conducted by a combination of automated, remote sampling and/or analysis systems, and manual sampling operations. This program provides early detection of radionuclide releases, minimizes the consequences, and assesses the impact on the public. Instrumentation installed at the release points monitor the atmospheric and aqueous releases from SRS operations. Ground water and air monitoring stations are strategically located throughout the site for radionuclide migration studies. The environmental radiological monitoring program at SRS includes: fixed monitoring stations for atmospheric radionuclide concentrations, aqueous monitors for surface water measurements, mobile laboratory operations for real-time, in-field measurements, aerial scanning for wide area contamination surveillance, and hand-held instruments for radionuclide-specific measurements. Rigorous environmentnal sampling surveillance coupled with laboratory analyses provide confirmatory results for all in-field measurements. Gaps in the technologies and development projects at SRS to fill these deficiencies are discussed in the context of customer needs and regulatory requirements

  7. The BAOBAB data portal and DACCIWA database

    Science.gov (United States)

    Brissebrat, Guillaume; Belmahfoud, Nizar; Cloché, Sophie; Ferré, Hélène; Fleury, Laurence; Mière, Arnaud; Ramage, Karim

    2017-04-01

    In the framework of the African Monsoon Multidisciplinary Analyses (AMMA) programme, several tools have been developed in order to boost the data and information exchange between researchers from different disciplines: a user-friendly data management and dissemination system, quasi real-time display websites and a scientific paper exchange collaborative tool. The information system is enriched by past and ongoing projects (IMPETUS, FENNEC, ESCAPE, QweCI, ACASIS, DACCIWA...) addressing meteorology, atmospheric chemistry, hydrology, extreme events, health, adaptation of human societies... It is becoming a reference information system on environmental issues in West Africa: BAOBAB (Base Afrique de l'Ouest beyond AMMA Base). The projects include airborne, ground-based and ocean measurements, social science surveys, satellite data use, modelling studies and value-added product development. Therefore, the BAOBAB data portal enables to access a great amount and a large variety of data: - 250 local observation datasets, that have been collected by operational networks since 1850, long term monitoring research networks and intensive scientific campaigns; - 1350 outputs of a socio-economics questionnaire; - 60 operational satellite products and several research products; - 10 output sets of meteorological and ocean operational models and 15 of research simulations. Data documentation complies with metadata international standards, and data are delivered into standard formats. The data request interface takes full advantage of the database relational structure and enables users to elaborate multicriteria requests (period, area, property…). The BAOBAB data portal counts about 900 registered users, and 50 data requests every month. The databases and data portal have been developed and are operated jointly by SEDOO and ESPRI in France: http://baoab.sedoo.fr. The ongoing DACCIWA (Dynamics-Aerosol-Chemistry-Cloud Interactions over West Africa) project uses the BAOBAB portal to

  8. Update on Monitoring Technologies for International Safeguards and Fissile Material Verification

    International Nuclear Information System (INIS)

    Croessmann, C. Dennis; Glidewell, Don D.; Mangan, Dennis L.; Smathers, Douglas C.

    1999-01-01

    Monitoring technologies are playing an increasingly important part in international safeguards and fissile material verification. The developments reduce the time an inspector must spend at a site while assuring continuity of knowledge. Monitoring technologies' continued development has produced new seal systems and integrated video surveillance advances under consideration for Trilateral Initiative use. This paper will present recent developments for monitoring systems at Embalse, Argentina, VNHEF, Sarov, Russian, and Savannah River Site, Aiken, South Carolina

  9. Recent Developments on Wireless Sensor Networks Technology for Bridge Health Monitoring

    Directory of Open Access Journals (Sweden)

    Guang-Dong Zhou

    2013-01-01

    Full Text Available Structural health monitoring (SHM systems have shown great potential to sense the responses of a bridge system, diagnose the current structural conditions, predict the expected future performance, provide information for maintenance, and validate design hypotheses. Wireless sensor networks (WSNs that have the benefits of reducing implementation costs of SHM systems as well as improving data processing efficiency become an attractive alternative to traditional tethered sensor systems. This paper introduces recent technology developments in the field of bridge health monitoring using WSNs. As a special application of WSNs, the requirements and characteristics of WSNs when used for bridge health monitoring are firstly briefly discussed. Then, the state of the art in WSNs-based bridge health monitoring systems is reviewed including wireless sensor, network topology, data processing technology, power management, and time synchronization. Following that, the performance validations and applications of WSNs in bridge health monitoring through scale models and field deployment are presented. Finally, some existing problems and promising research efforts for promoting applications of WSNs technology in bridge health monitoring throughout the world are explored.

  10. Regional Ocean Data Portal: Transforming Information to Knowledge

    Science.gov (United States)

    Howard, M. K.; Gayanilo, F. C.; Jochens, A. E.

    2009-12-01

    producers, recreational boaters, etc.) workshops were held to elicit user needs and requirements for observing system products for each group. The GCOOS-RA’s Products and Services Committee and Education and Outreach Council have gone through similar activities aimed at determining what products various users groups want. We have been sensitive to the private sector when deciding which products to produce. While science users want numbers, users of all types mainly want maps. We have tried to develop flexible capabilities within the portal that helps users to create their own fused products, ad hoc, for a variety of output devices, from desktop screens to the smart phones. We will discuss how our data management system has evolved within the backdrop of rapidly changing technologies and diverse community requirements.

  11. Development of a Remote Monitoring System Using Meteor Burst Technology

    International Nuclear Information System (INIS)

    Ewanic, M.A.; Dunstan, M.T.; Reichhardt, D.K.

    2006-01-01

    Monitoring the cleanup and closure of contaminated sites requires extensive data acquisition, processing, and storage. At remote sites, the task of monitoring often becomes problematical due to the lack of site infrastructure (i.e., electrical power lines, telephone lines, etc.). MSE Technology Applications, Inc. (MSE) has designed an economical and efficient remote monitoring system that will handle large amounts of data; process the data, if necessary; and transmit this data over long distances. Design criteria MSE considered during the development of the remote monitoring system included: the ability to handle multiple, remote sampling points with independent sampling frequencies; robust (i.e., less susceptible to moisture, heat, and cold extremes); independent of infrastructure; user friendly; economical; and easy to expand system capabilities. MSE installed and tested a prototype system at the Mike Mansfield Advanced Technology Center (MMATC), Butte, Montana, in June 2005. The system MSE designed and installed consisted of a 'master' control station and two remote 'slave' stations. Data acquired at the two slave stations were transmitted to the master control station, which then transmits a complete data package to a ground station using meteor burst technology. The meteor burst technology has no need for hardwired land-lines or man-made satellites. Instead, it uses ionized particles in the Earth's atmosphere to propagate a radio signal. One major advantage of the system is that it can be configured to accept data from virtually any type of device, so long as the signal from the device can be read and recorded by a standard data-logger. In fact, MSE has designed and built an electrical resistivity monitoring system that will be powered and controlled by the meteor burst system components. As sites move through the process of remediation and eventual closure, monitoring provides data vital to the successful long term management of the site. The remote

  12. Next Gen One Portal Usability Evaluation

    Science.gov (United States)

    Cross, E. V., III; Perera, J. S.; Hanson, A. M.; English, K.; Vu, L.; Amonette, W.

    2018-01-01

    Each exercise device on the International Space Station (ISS) has a unique, customized software system interface with unique layouts / hierarchy, and operational principles that require significant crew training. Furthermore, the software programs are not adaptable and provide no real-time feedback or motivation to enhance the exercise experience and/or prevent injuries. Additionally, the graphical user interfaces (GUI) of these systems present information through multiple layers resulting in difficulty navigating to the desired screens and functions. These limitations of current exercise device GUI's lead to increased crew time spent on initiating, loading, performing exercises, logging data and exiting the system. To address these limitations a Next Generation One Portal (NextGen One Portal) Crew Countermeasure System (CMS) was developed, which utilizes the latest industry guidelines in GUI designs to provide an intuitive ease of use approach (i.e., 80% of the functionality gained within 5-10 minutes of initial use without/limited formal training required). This is accomplished by providing a consistent interface using common software to reduce crew training, increase efficiency & user satisfaction while also reducing development & maintenance costs. Results from the usability evaluations showed the NextGen One Portal UI having greater efficiency, learnability, memorability, usability and overall user experience than the current Advanced Resistive Exercise Device (ARED) UI used by astronauts on ISS. Specifically, the design of the One-Portal UI as an app interface similar to those found on the Apple and Google's App Store, assisted many of the participants in grasping the concepts of the interface with minimum training. Although the NextGen One-Portal UI was shown to be an overall better interface, observations by the test facilitators noted specific exercise tasks appeared to have a significant impact on the NextGen One-Portal UI efficiency. Future updates to

  13. New and Emerging Technologies for Real-Time Air and Surface Beryllium Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Phifer, B.E. Jr.; Churnetski, E.L.; Cooke, L.E.; Reed, J.J.; Howell, M.L.; Smith, V.D.

    2001-09-01

    In this study, five emerging technologies were identified for real-time monitoring of airborne beryllium: Microwave-Induced Plasma Spectroscopy (MIPS), Aerosol Beam-Focused Laser-Induced Plasma Spectroscopy (ABFLIPS), Laser-Induced Breakdown Spectroscopy (LIBS), Surfaced-Enhanced Raman Scattering (SERS) Spectroscopy, and Micro-Calorimetric Spectroscopy (CalSpec). Desired features of real-time air beryllium monitoring instrumentation were developed from the Y-12 CBDPP. These features were used as guidelines for the identification of potential technologies as well as their unique demonstrated capability to provide real-time monitoring of similar materials. However, best available technologies were considered, regardless of their ability to comply with the desired features. None of the five technologies have the capability to measure the particle size of airborne beryllium. Although reducing the total concentration of airborne beryllium is important, current literature suggests that reducing or eliminating the concentration of respirable beryllium is critical for worker health protection. Eight emerging technologies were identified for surface monitoring of beryllium. CalSpec, MIPS, SERS, LIBS, Laser Ablation, Absorptive Stripping Voltametry (ASV), Modified Inductively Coupled Plasma (ICP) Spectroscopy, and Gamma BeAST. Desired features of real-time surface beryllium monitoring were developed from the Y-12 CBDPP. These features were used as guidelines for the identification of potential technologies. However, the best available technologies were considered regardless of their ability to comply with the desired features.

  14. Dose patient verification during treatment using an amorphous silicon electronic portal imaging device in radiotherapy

    International Nuclear Information System (INIS)

    Berger, Lucie

    2006-01-01

    Today, amorphous silicon electronic portal imaging devices (aSi EPID) are currently used to check the accuracy of patient positioning. However, they are not use for dose reconstruction yet and more investigations are required to allow the use of an aSi EPID for routine dosimetric verification. The aim of this work is first to study the dosimetric characteristics of the EPID available at the Institut Curie and then, to check patient dose during treatment using these EPID. First, performance optimization of the Varian aS500 EPID system is studied. Then, a quality assurance system is set up in order to certify the image quality on a daily basis. An additional study on the dosimetric performance of the aS500 EPID is monitored to assess operational stability for dosimetry applications. Electronic portal imaging device is also a useful tool to improve IMRT quality control. The validation and the quality assurance of a portal dose image prediction system for IMRT pre-treatment quality control are performed. All dynamic IMRT fields are verified in clinical routine with the new method based on portal dosimetry. Finally, a new formalism for in vivo dosimetry using transit dose measured with EPID is developed and validated. The absolute dose measurement issue using aSi EPID is described and the midplane dose determination using in vivo dose measurements in combination with portal imaging is used with 3D-conformal-radiation therapy. (author) [fr

  15. Metabolic effects of portal vein sensing.

    Science.gov (United States)

    Mithieux, G

    2014-09-01

    The extrinsic gastrointestinal nerves are crucial in the sensing of nutrients and hormones and its translation in terms of control of food intake. Major macronutrients like glucose and protein are sensed by the extrinsic nerves located in the portal vein walls, which signal to the brain and account for the satiety phenomenon they promote. Glucose is sensed in the portal vein by neurons expressing the glucose receptor SGLT3, which activate the main regions of the brain involved in the control of food intake. Proteins indirectly act on food intake by inducing intestinal gluconeogenesis and its sensing by the portal glucose sensor. The mechanism involves a prior antagonism by peptides of the μ-opioid receptors present in the portal vein nervous system and a reflex arc with the brain inducing intestinal gluconeogenesis. In a comparable manner, short-chain fatty acids produced from soluble fibre act via intestinal gluconeogenesis to exert anti-obesity and anti-diabetic effects. In the case of propionate, the mechanism involves a prior activation of the free fatty acid receptor FFAR3 present in the portal nerves and a reflex arc initiating intestinal gluconeogenesis. © 2014 John Wiley & Sons Ltd.

  16. Monitoring human health behaviour in one's living environment: a technological review.

    Science.gov (United States)

    Lowe, Shane A; Ólaighin, Gearóid

    2014-02-01

    The electronic monitoring of human health behaviour using computer techniques has been an active research area for the past few decades. A wide array of different approaches have been investigated using various technologies including inertial sensors, Global Positioning System, smart homes, Radio Frequency IDentification and others. It is only in recent years that research has turned towards a sensor fusion approach using several different technologies in single systems or devices. These systems allow for an increased volume of data to be collected and for activity data to be better used as measures of behaviour. This change may be due to decreasing hardware costs, smaller sensors, increased power efficiency or increases in portability. This paper is intended to act as a reference for the design of multi-sensor behaviour monitoring systems. The range of technologies that have been used in isolation for behaviour monitoring both in research and commercial devices are reviewed and discussed. Filtering, range, sensitivity, usability and other considerations of different technologies are discussed. A brief overview of commercially available activity monitors and their technology is also included. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Arachidonic acid metabolites and endothelial dysfunction of portal hypertension.

    Science.gov (United States)

    Sacerdoti, David; Pesce, Paola; Di Pascoli, Marco; Brocco, Silvia; Cecchetto, Lara; Bolognesi, Massimo

    2015-07-01

    Increased resistance to portal flow and increased portal inflow due to mesenteric vasodilatation represent the main factors causing portal hypertension in cirrhosis. Endothelial cell dysfunction, defined as an imbalance between the synthesis, release, and effect of endothelial mediators of vascular tone, inflammation, thrombosis, and angiogenesis, plays a major role in the increase of resistance in portal circulation, in the decrease in the mesenteric one, in the development of collateral circulation. Reduced response to vasodilators in liver sinusoids and increased response in the mesenteric arterioles, and, viceversa, increased response to vasoconstrictors in the portal-sinusoidal circulation and decreased response in the mesenteric arterioles are also relevant to the pathophysiology of portal hypertension. Arachidonic acid (AA) metabolites through the three pathways, cyclooxygenase (COX), lipoxygenase, and cytochrome P450 monooxygenase and epoxygenase, are involved in endothelial dysfunction of portal hypertension. Increased thromboxane-A2 production by liver sinusoidal endothelial cells (LSECs) via increased COX-1 activity/expression, increased leukotriens, increased epoxyeicosatrienoic acids (EETs) (dilators of the peripheral arterial circulation, but vasoconstrictors of the portal-sinusoidal circulation), represent a major component in the increased portal resistance, in the decreased portal response to vasodilators and in the hyper-response to vasoconstrictors. Increased prostacyclin (PGI2) via COX-1 and COX-2 overexpression, and increased EETs/heme-oxygenase-1/K channels/gap junctions (endothelial derived hyperpolarizing factor system) play a major role in mesenteric vasodilatation, hyporeactivity to vasoconstrictors, and hyper-response to vasodilators. EETs, mediators of liver regeneration after hepatectomy and of angiogenesis, may play a role in the development of regenerative nodules and collateral circulation, through stimulation of vascular endothelial

  18. Commissioning of Portal Dosimetry and characterization of an EPID

    International Nuclear Information System (INIS)

    Olbi, D.S.; Sales, C.P.; Nakandakari, M.V.N.

    2016-01-01

    The development of technologies compensator blocks, MLC, high dose rate accelerators, treatment planning systems, among others, permitted that new treatment techniques in radiotherapy were created. Such techniques have the capacity to modulate radiation beam fluency (IMRT, VMAT), or to deliver high doses in few fractions or unique fractions (SRS). Following the same tendency, quality control of planning became more complex. It is necessary to evaluate the fluency delivered by the accelerator. Its levels of does and its spatial distribution should co-occur with the fluency calculated by TPS. Acquisition of new detector devices in quality control of treatments is fundamental to apply techniques. Portal Vision is a device EPID has the capacity to operate either in image mode or dosimetry mode, with the allowance of Portal Dosimetry. To evaluated planning in IMRT, the device is irradiated using planning e, therefore, the fluency measured is compared with calculated fluency, through gamma analysis. The aim of this work was to perform tests of commissioning of this device. (author)

  19. Endovascular management for significant iatrogenic portal vein bleeding.

    Science.gov (United States)

    Kim, Jong Woo; Shin, Ji Hoon; Park, Jonathan K; Yoon, Hyun-Ki; Ko, Gi-Young; Gwon, Dong Il; Kim, Jin Hyoung; Sung, Kyu-Bo

    2017-11-01

    Background Despite conservative treatment, hemorrhage from an intrahepatic branch of the portal vein can cause hemodynamic instability requiring urgent intervention. Purpose To retrospectively report the outcomes of hemodynamically significant portal vein bleeding after endovascular management. Material and Methods During a period of 15 years, four patients (2 men, 2 women; median age, 70.5 years) underwent angiography and embolization for iatrogenic portal vein bleeding. Causes of hemorrhage, angiographic findings, endovascular treatment, and complications were reported. Results Portal vein bleeding occurred after percutaneous liver biopsy (n = 2), percutaneous radiofrequency ablation (n = 1), and percutaneous cholecystostomy (n = 1). The median time interval between angiography and percutaneous procedure was 5 h (range, 4-240 h). Common hepatic angiograms including indirect mesenteric portograms showed active portal vein bleeding into the peritoneal cavity with (n = 1) or without (n = 2) an arterioportal (AP) fistula, and portal vein pseudoaneurysm alone with an AP fistula (n = 1). Successful transcatheter arterial embolization (n = 2) or percutaneous transhepatic portal vein embolization (n = 2) was performed. Embolic materials were n-butyl cyanoacrylate alone (n = 2) or in combination with gelatin sponge particles and coils (n = 2). There were no major treatment-related complications or patient mortality within 30 days. Conclusion Patients with symptomatic or life-threatening portal vein bleeding following liver-penetrating procedures can successfully be managed with embolization.

  20. Patient Portals as a Means of Information and Communication Technology Support to Patient- Centric Care Coordination - the Missing Evidence and the Challenges of Evaluation. A joint contribution of IMIA WG EVAL and EFMI WG EVAL.

    Science.gov (United States)

    Rigby, M; Georgiou, A; Hyppönen, H; Ammenwerth, E; de Keizer, N; Magrabi, F; Scott, P

    2015-08-13

    To review the potential contribution of Information and Communication Technology (ICT) to enable patient-centric and coordinated care, and in particular to explore the role of patient portals as a developing ICT tool, to assess the available evidence, and to describe the evaluation challenges. Reviews of IMIA, EFMI, and other initiatives, together with literature reviews. We present the progression from care coordination to care integration, and from patient-centric to person-centric approaches. We describe the different roles of ICT as an enabler of the effective presentation of information as and when needed. We focus on the patient's role as a co-producer of health as well as the focus and purpose of care. We discuss the need for changing organisational processes as well as the current mixed evidence regarding patient portals as a logical tool, and the reasons for this dichotomy, together with the evaluation principles supported by theoretical frameworks so as to yield robust evidence. There is expressed commitment to coordinated care and to putting the patient in the centre. However to achieve this, new interactive patient portals will be needed to enable peer communication by all stakeholders including patients and professionals. Few portals capable of this exist to date. The evaluation of these portals as enablers of system change, rather than as simple windows into electronic records, is at an early stage and novel evaluation approaches are needed.

  1. Disastrous Portal Vein Embolization Turned into a Successful Intervention

    Energy Technology Data Exchange (ETDEWEB)

    Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland); Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at [Universitätsklinikum St. Pölten-Lilienfeld, Institute of Medical Radiology, Diagnostic, Intervention (Austria); Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch; Kara, Levent, E-mail: levent.kara@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland)

    2015-10-15

    Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

  2. Technological monitoring radar: a weak signals interpretation tool for the identification of strategic surprises

    Directory of Open Access Journals (Sweden)

    Adalton Ozaki

    2011-07-01

    Full Text Available In the current competitive scenario, marked by rapid and constant changes, it is vital that companies actively monitor the business environment, in search of signs which might anticipate changes. This study poses to propose and discuss a tool called Technological Monitoring Radar, which endeavours to address the following query: “How can a company systematically monitor the environment and capture signs that anticipate opportunities and threats concerning a particular technology?”. The literature review covers Competitive Intelligence, Technological Intelligence, Environmental Analysis and Anticipative Monitoring. Based on the critical analysis of the literature, a tool called Technological Monitoring Radar is proposed comprising five environments to be monitored (political, economical, technological, social and competition each of which with key topics for analysis. To exemplify the use of the tool, it is applied to the smartphone segment in an exclusively reflexive manner, and without the participation of a specific company. One of the suggestions for future research is precisely the application of the proposed methodology in an actual company. Despite the limitation of this being a theoretical study, the example demonstrated the tool´s applicability. The radar prove to be very useful for a company that needs to monitor the environment in search of signs of change. This study´s main contribution is to relate different fields of study (technological intelligence, environmental analysis and anticipative monitoring and different approaches to provide a practical tool that allows a manager to identify and better visualize opportunities and threats, thus avoiding strategic surprises in the technological arena.Key words: Technological monitoring. Technological intelligence. Competitive intelligence. Weak signals.

  3. Studi Respon Seismik Penggunaan Steel Slit Damper (SSD pada Portal Baja

    Directory of Open Access Journals (Sweden)

    Lisa Ika Arumsari

    2012-09-01

    Full Text Available Salah satu metode yang dapat digunakan untuk mengurangi dampak dari beban gempa terhadap portal baja adalah menggunakan peredam. Steel Slit Damper (SSD adalah salah satu jenis peredam yang dibuat dari sejumlah pelat baja lunak berbentuk segi-4 yang dimodelkan sebagai pegas-pegas yang disusun secara seri. Energi akibat gempa disalurkan melalui strip-strip damper yang mudah meleleh ketika perangkat mengalami deformasi inelastis siklik. SSD mendisipasi energi melalui pembentukan sendi plastis atau pelelehan pelat damper. Pada penelitian ini dilakukan analisa respon seismik Steel Slit Damper (SSD pada portal baja 1 lantai yang menerima beban lateral berupa beban gempa, dengan membandingkan portal baja konvensional, portal baja inverted-v, dan portal baja dengan SSD. Hasil analisa menunjukkan bahwa gaya geser, gaya normal, dan momen yang dihasikan portal dengan SSD lebih kecil hingga 80,49% dari gaya-gaya yang dihasilkan portal konvensional, tetapi gaya-gaya tersebut masih lebih besar daripada yang dihasilkan portal inverted-V. Portal dengan SSD dapat memperkecil simpangan sebesar 94,12% pada portal konvensional dan sebesar 33,33% pada portal bracing inverted-v. Hasil penelitian juga menunjukkan bahwa portal SSD memiliki daktilitas 105,85% lebih tinggi dari portal konvensional dan 298,67% lebih tinggi dari portal bracing inverted-v

  4. Endothelial dysfunction in the regulation of portal hypertension

    Science.gov (United States)

    Iwakiri, Yasuko

    2013-01-01

    Portal hypertension is caused by an increased intrahepatic resistance, a major consequence of cirrhosis. Endothelial dysfunction in liver sinusoidal endothelial cells (LSECs) decreases the production of vasodilators, such as nitric oxide (NO) and favors vasoconstriction. This contributes to an increased vascular resistance in the intrahepatic/sinusoidal microcirculation. Portal hypertension, once developed, causes endothelial cell (EC) dysfunction in the extrahepatic, i.e. splanchnic and systemic, circulation. Unlike LSEC dysfunction, EC dysfunction in the splanchnic and systemic circulation overproduces vasodilator molecules, leading to arterial vasodilatation. In addition, portal hypertension leads to the formation of portosystemic collateral vessels. Both arterial vasodilatation and portosystemic collateral vessel formation exacerbate portal hypertension by increasing the blood flow through the portal vein. Pathologic consequences, such as esophageal varices and ascites, result. While the sequence of pathological vascular events in cirrhosis and portal hypertension have been elucidated, the underlying cellular and molecular mechanisms causing EC dysfunctions are not yet fully understood. This review article summarizes the current cellular and molecular studies on EC dysfunctions found during the development of cirrhosis and portal hypertension with a focus on intra- and extrahepatic circulation. The article ends by discussing future directions of study for EC dysfunctions. PMID:21745318

  5. Duplication of the Portal Vein: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Shin, Hyeong Cheol; Jou, Sung Shick; Han, Jong Kyu; Kim, Il Young [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2009-12-15

    The duplication of the portal vein is an uncommon congenital anomaly. To date, only four cases have been reported in the medical literature. This anomaly can cause portal hypertension in pediatric patients. In addition, duplication of the portal vein has various patterns of connection with a splenic vein or mesenteric veins, and it can lie anterior or posterior to the duodenum. We report the MDCT findings of an adult patient with duplication of the portal vein that was found incidentally

  6. MR and angiography: Evaluation of the hemodynamics of portal hypertension

    International Nuclear Information System (INIS)

    Torres, W.E.; Gaylord, G.M.; Whitmire, L.; Chuang, V.P.; Bernardino, M.E.

    1986-01-01

    Forty-two MR imaging examinations and angiographic procedures in 38 patients with portal hypertension were compared for how well the images depicted portal perfusion and direction of flow, portal vein thrombosis, and the presence and type of shunt. Thirty-three MR imaging studies indicated grade I or II portal flow. In 29 cases portal flow was grade I or II by angiography; in the remaining cases the flow was grade IV. In a total of eight cases portal flow was grade IV by angiography, but none appeared to be grade IV on MR imaging. Both MR imaging and angiography detected portal vein thrombosis (41 of 42 cases). MR imaging and angiography agreed as to whether a shunt was present or absent, and patent or occluded (41 of 42 cases). Currently, MR imaging is an unsatisfactory modality by which to grade portal flow. MR imaging does depict portal vein thrombosis well, and can be used to determine patency of surgical shunts

  7. Arms Control and nonproliferation technologies: Technology options and associated measures for monitoring a Comprehensive Test Ban, Second quarter

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Leslie A.

    1994-01-01

    This newsletter contains reprinted papers discussing technology options and associated measures for monitoring a Comprehensive Test Ban Treaty (CTBT). These papers were presented to the Conference on Disarmament (CD) in May and June 1994. An interagency Verification Monitoring Task Force developed the papers. The task force included participants from the Arms Control and Disarmament Agency, the Department of Defense, the Department of Energy, the Intelligence Community, the Department of Interior, and the Department of State. The purpose of this edition of Arms Control and Nonproliferation Technologies is to share these papers with the broad base of stakeholders in a CTBT and to facilitate future technology discussions. The papers in the first group discuss possible technology options for monitoring a CTBT in all environments (underground, underwater, atmosphere, and space). These technologies, along with on-site inspections, would facilitate CTBT monitoring by treaty participants. The papers in the second group present possible associated measures, e.g., information exchanges and transparency measures, that would build confidence among states participating in a CTBT.

  8. Testing telehealth using technology-enhanced nurse monitoring.

    Science.gov (United States)

    Grant, Leslie A; Rockwood, Todd; Stennes, Leif

    2014-10-01

    Technology-enhanced nurse monitoring is a telehealth solution that helps nurses with assessment, diagnosis, and triage of older adults living in community-based settings. This technology links biometric and nonbiometric sensors to a data management system that is monitored remotely by RNs and unlicensed support staff. Nurses faced a number of challenges related to data interpretation, including making clinical inferences from nonbiometric data, integrating data generated by three different telehealth applications into a clinically meaningful cognitive framework, and figuring out how best to use nursing judgment to make valid inferences from online reporting systems. Nurses developed expertise over the course of the current study. The sponsoring organization achieved a high degree of organizational knowledge about how to use these systems more effectively. Nurses saw tremendous value in the telehealth applications. The challenges, learning curve, and organizational improvements are described. Copyright 2014, SLACK Incorporated.

  9. Extrahepatic Portal Hypertension following Liver Transplantation: a Rare but Challenging Problem

    Directory of Open Access Journals (Sweden)

    B. Malassagne

    1998-01-01

    Full Text Available This study reports our experience of 8 cases of extrahepatic portal hypertension after 273 orthotopic liver transplantations in 244 adult patients over a 10- year period. The main clinical feature was ascites, and the life-threatening complication was variceal bleeding. Extrahepatic portal hypertension was caused by portal vein stenosis in 6 patients, and left-sided portal hypertension in 2 patients after inadventent ligation of portal venous tributaries or portasystemic shunts. All patients with portal vein stenosis had complete relief of portal hypertension after percutaneous transhepatic venoplasty (n=4 or surgical reconstruction (n=2, after a median follow-up of 33 (range: 6–62 months. Of the 2 patients with left-sided portal hypertension, one died after splenectomy and one rebled 6 months after left colectomy. This study suggests that extrahepatic portal hypertension is a series complication after liver transplantation that could be prevented by meticulous portal anastomosis and closure of portal tributaries or portasystemic shunts to improve the portal venous flow. However, any ligation has to be performed under ultrasound guidance to avoid inadventent venous ligations.

  10. Healthcare personnel perceptions of hand hygiene monitoring technology.

    Science.gov (United States)

    Ellingson, Katherine; Polgreen, Philip M; Schneider, Amy; Shinkunas, Laura; Kaldjian, Lauris C; Wright, Donald; Thomas, Geb W; Segre, Alberto M; Herman, Ted; McDonald, L Clifford; Sinkowitz-Cochran, Ronda

    2011-11-01

    To assess healthcare personnel (HCP) perceptions regarding implementation of sensor-based electronic systems for automated hand hygiene adherence monitoring. Using a mixed-methods approach, structured focus groups were designed to elicit quantitative and qualitative responses on familiarity, comfort level, and perceived impact of sensor-based hand hygiene adherence monitoring. A university hospital, a Veterans Affairs hospital, and a community hospital in the Midwest. Focus groups were homogenous by HCP type, with separate groups held for leadership, midlevel management, and frontline personnel at each hospital. Overall, 89 HCP participated in 10 focus groups. Levels of familiarity and comfort with electronic oversight technology varied by HCP type; when compared with frontline HCP, those in leadership positions were significantly more familiar with ([Formula: see text]) and more comfortable with ([Formula: see text]) the technology. The most common concerns cited by participants across groups included lack of accuracy in the data produced, such as the inability of the technology to assess the situational context of hand hygiene opportunities, and the potential punitive use of data produced. Across groups, HCP had decreased tolerance for electronic collection of spatial-temporal data, describing such oversight as Big Brother. While substantial concerns were expressed by all types of HCP, participants' recommendations for effective implementation of electronic oversight technologies for hand hygiene monitoring included addressing accuracy issues before implementation and transparent communication with frontline HCP about the intended use of the data.

  11. The questions of working out radiology patterns of portal hypertension

    International Nuclear Information System (INIS)

    Vyikman, Ya.E.

    2008-01-01

    A foundation for radiological patterns of each type of portal hypertension (PH) at various stages of its development. Portal blood pressure, diameter of splenic and portal veins, volume blood flow velocity in the portal and splenic veins, incidence of hypersplenism, enlargement of the caudate lobe of the liver and gallbladder fossa are the most informative in differentiation of various forms of portal hypertension

  12. Calcification in the portal venous system demonstrated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hadar, H; Sommer, R

    1983-08-01

    The CT appearance of calcification in the portal venous system in a patient with chronic alcoholic cirrhosis is presented. Reported cases of radiologically detectable calcification in the portal system are rare, and most of them have been associated with longstanding portal hypertension. We presume that with CT this diagnosis will be made more frequently. In the presence of calcification in the portal venous system, portal vein thrombosis is highly probable. This information is of obvious importance to the surgeon contemplating a portal decompressive shunt procedure.

  13. Evaluation of portal hypertension by MR portography

    International Nuclear Information System (INIS)

    Nagaoka, Shirou; Hagiwara, Masaru; Imanisi, Yosimasa

    1997-01-01

    Seventy-eight examinations of MR portography were totally performed in 24 controls and 33 patients with esophageal varices. Portal vein, SMV, hepatic vein, and IVC were entirely depicted in 21, 24, 22, and 24, respectively, of the 24 controls. As to intrahepatic upward branches of portal vein in the right lobe of the liver, the 4th branch was at least depicted in all of the 24. Although the portal vein trunk and SMV were entirely depicted in all of the 8 patients without treatment and liver dysfunction of Child A, there was no depiction of them in 1 of the 8 patients with liver dysfunction of Child B, and 1 of 5 patients with liver dysfunction of Child C. The 4th upward branch of portal vein in the right lobe of the liver was depicted in none of the 33 patients. Besides, none of the intrahepatic portal branches were depicted in 1 of 8 patients without treatment and liver dysfunction of Child B, and 1 of the 5 patients without treatment and liver dysfunction of Child C. There was a significant difference of depicted terminal upward branch of portal vein between the controls and patients without any treatment. In the patients without any significant difference of depicted terminal upward branch of portal vein was also present between Child's classification A and Child's classification B and C. Gastric coronary vein varices were detected by MR portography is 18 of 19 patients without treatment on the esophageal varices, and paraesophageal/esophageal varices were also depicted by MR portography in 13 of the 19. The collaterals were depicted by MR portography in all of the 6 patients with recurrent collaterals after Hassab's operation or splenectomy. MR portography was able to depict flow in trunk branches and collaterals of the portal vein system in a physiological state. (K.H.)

  14. Evaluation of portal hypertension by MR portography

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shirou; Hagiwara, Masaru; Imanisi, Yosimasa [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1997-02-01

    Seventy-eight examinations of MR portography were totally performed in 24 controls and 33 patients with esophageal varices. Portal vein, SMV, hepatic vein, and IVC were entirely depicted in 21, 24, 22, and 24, respectively, of the 24 controls. As to intrahepatic upward branches of portal vein in the right lobe of the liver, the 4th branch was at least depicted in all of the 24. Although the portal vein trunk and SMV were entirely depicted in all of the 8 patients without treatment and liver dysfunction of Child A, there was no depiction of them in 1 of the 8 patients with liver dysfunction of Child B, and 1 of 5 patients with liver dysfunction of Child C. The 4th upward branch of portal vein in the right lobe of the liver was depicted in none of the 33 patients. Besides, none of the intrahepatic portal branches were depicted in 1 of 8 patients without treatment and liver dysfunction of Child B, and 1 of the 5 patients without treatment and liver dysfunction of Child C. There was a significant difference of depicted terminal upward branch of portal vein between the controls and patients without any treatment. In the patients without any significant difference of depicted terminal upward branch of portal vein was also present between Child`s classification A and Child`s classification B and C. Gastric coronary vein varices were detected by MR portography is 18 of 19 patients without treatment on the esophageal varices, and paraesophageal/esophageal varices were also depicted by MR portography in 13 of the 19. The collaterals were depicted by MR portography in all of the 6 patients with recurrent collaterals after Hassab`s operation or splenectomy. MR portography was able to depict flow in trunk branches and collaterals of the portal vein system in a physiological state. (K.H.)

  15. Splenomegaly, hyperkinetic splenic flow and portal hypertension in colitis

    International Nuclear Information System (INIS)

    Friman, L.

    1980-01-01

    Four patients with a long history of colitis, splenomegaly, hypersplenism and portal hypertension were examined with angiography, both with contrast medium and isotopes, liver-spleen scintigraphy and recording of portal pressure. At angiography hyperkinetic splenic and portal blood flow was demonstrated. The increased flow causes increased portal pressure, which probably gives rise to changes in the liver often considered as slight cirrhosis at microscopy. The scintigraphic findings differed from Laennec cirrhosis. The liver uptake was homogeneous and no activity in the skeleton was recorded. Splenectomy cures both the hypersplenism and portal hypertension. (Auth.)

  16. Portal hypertension as portrayed by marked hepatosplenomegaly: case report

    International Nuclear Information System (INIS)

    Greene, R.A.

    1987-01-01

    The liver is vulnerable to as host of disease processes, including portal hypertension. This is a severe hepatic condition in which the liver is subject to numerous imbalances: increased hepatic blood flow, increased portal vein pressure due to extrahepatic portal vein obstruction, and/or increases in hepatic blood flow resistance. Although many diseases states may be responsible for the development of portal hypertension, it is most commonly associated with moderately severe or advanced cirrhosis. Advanced, untreated portal hypertension may cause additional complications such as hepatosplenomegaly, gastrointestinal bleeding, and ascites

  17. Splenomegaly, hyperkinetic splenic flow and portal hypertension in colitis

    Energy Technology Data Exchange (ETDEWEB)

    Friman, L [Serafimerlasarettet, Stockholm (Sweden)

    1980-01-01

    Four patients with a long history of colitis, splenomegaly, hypersplenism and portal hypertension were examined with angiography, both with contrast medium and isotopes, liver-spleen scintigraphy and recording of portal pressure. At angiography hyperkinetic splenic and portal blood flow was demonstrated. The increased flow causes increased portal pressure, which probably gives rise to changes in the liver often considered as slight cirrhosis at microscopy. The scintigraphic findings differed from Laennec cirrhosis. The liver uptake was homogeneous and no activity in the skeleton was recorded. Splenectomy cures both the hypersplenism and portal hypertension.

  18. Virtual research environments from portals to science gateways

    CERN Document Server

    Allan, Robert N

    2009-01-01

    Virtual Research Environments examines making Information and Communication Technologies (ICT) usable by researchers working to solve "grand challenge” problems in many disciplines from social science to particle physics. It is driven by research the authors have carried out to evaluate researchers' requirements in using information services via web portals and in adapting collaborative learning tools to meet their more diverse needs, particularly in a multidisciplinary study.This is the motivation for what the authors have helped develop into the UK Virtual Research Environments (VRE)

  19. Improvements to the Ontology-based Metadata Portal for Unified Semantics (OlyMPUS)

    Science.gov (United States)

    Linsinbigler, M. A.; Gleason, J. L.; Huffer, E.

    2016-12-01

    The Ontology-based Metadata Portal for Unified Semantics (OlyMPUS), funded by the NASA Earth Science Technology Office Advanced Information Systems Technology program, is an end-to-end system designed to support Earth Science data consumers and data providers, enabling the latter to register data sets and provision them with the semantically rich metadata that drives the Ontology-Driven Interactive Search Environment for Earth Sciences (ODISEES). OlyMPUS complements the ODISEES' data discovery system with an intelligent tool to enable data producers to auto-generate semantically enhanced metadata and upload it to the metadata repository that drives ODISEES. Like ODISEES, the OlyMPUS metadata provisioning tool leverages robust semantics, a NoSQL database and query engine, an automated reasoning engine that performs first- and second-order deductive inferencing, and uses a controlled vocabulary to support data interoperability and automated analytics. The ODISEES data discovery portal leverages this metadata to provide a seamless data discovery and access experience for data consumers who are interested in comparing and contrasting the multiple Earth science data products available across NASA data centers. Olympus will support scientists' services and tools for performing complex analyses and identifying correlations and non-obvious relationships across all types of Earth System phenomena using the full spectrum of NASA Earth Science data available. By providing an intelligent discovery portal that supplies users - both human users and machines - with detailed information about data products, their contents and their structure, ODISEES will reduce the level of effort required to identify and prepare large volumes of data for analysis. This poster will explain how OlyMPUS leverages deductive reasoning and other technologies to create an integrated environment for generating and exploiting semantically rich metadata.

  20. Design and Implementation of a Portal for the Medical Equipment Market: MEDICOM

    Science.gov (United States)

    Kalivas, Dimitris; Panou-Diamandi, Ourania; Zeelenberg, Cees; van Nimwegen, Chris

    2001-01-01

    Management Systems are used for the system's databases. The end-user interface is implemented using HTML, Javascript, Java applets, and XML documents. Communication between the Portal and the manufacturers' servers is implemented using a CORBA interface. Remote administration of the Portal is enabled by dynamically-generated HTML interfaces based on XML documents. A representative group of users evaluated the system. The aim of the evaluation was validation of the usability of all of MEDICOM's functionality. The evaluation procedure was based on ISO/IEC 9126 Information technology - Software product evaluation - Quality characteristics and guidelines for their use. Results The overall user evaluation of the MEDICOM system was very positive. The MEDICOM system was characterized as an innovative concept that brings significant added value to medical-equipment commerce. Conclusions The eventual benefits of the MEDICOM system are (a) establishment of a worldwide-accessible marketplace between manufacturers and health care professionals that provides up-to-date and high-quality product information in an easy and friendly way and (b) enhancement of the efficiency of marketing procedures and after-sales support. PMID:11772547

  1. Design and implementation of a portal for the medical equipment market: MEDICOM.

    Science.gov (United States)

    Palamas, S; Kalivas, D; Panou-Diamandi, O; Zeelenberg, C; van Nimwegen, C

    2001-01-01

    the system s databases. The end-user interface is implemented using HTML, Javascript, Java applets, and XML documents. Communication between the Portal and the manufacturers servers is implemented using a CORBA interface. Remote administration of the Portal is enabled by dynamically-generated HTML interfaces based on XML documents. A representative group of users evaluated the system. The aim of the evaluation was validation of the usability of all of MEDICOM s functionality. The evaluation procedure was based on ISO/IEC 9126 Information technology - Software product evaluation - Quality characteristics and guidelines for their use. The overall user evaluation of the MEDICOM system was very positive. The MEDICOM system was characterized as an innovative concept that brings significant added value to medical-equipment commerce. The eventual benefits of the MEDICOM system are (a) establishment of a worldwide-accessible marketplace between manufacturers and health care professionals that provides up-to-date and high-quality product information in an easy and friendly way and (b) enhancement of the efficiency of marketing procedures and after-sales support.

  2. Porto-systemic collaterals in cirrhosis of the liver. Selective percutaneous transhepatic catheterization of the portal venous system in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hoevels, J; Lunderquist, A; Tylen, U; Simert, G [Lund Univ. (Sweden)

    1979-01-01

    In 93 patients with cirrhosis of the liver and portal venous hypertension the main tributaries of the portal vein were examined by percutaneous transhepatic catheterization. The appearance and degree of porto-systemic collaterals were analysed. Esophageal varices were demonstrated in 82 patients. No correlation was found between the portal venous pressure and the extent of porto-systemic communications.

  3. Scintiphotosplenoportography in patients with portal hypertension

    International Nuclear Information System (INIS)

    Aijaz, A.

    1990-01-01

    Scintiphotosplenoportograpy (SSP) was performed in five normals and 25 patients with portal hypertension using Tc-99m tin colloid. 12 patients were cirrhotic and 13 had idiopathic portal hypertension (IPH). Analogue and fast frame dynamic studies were performed and subsequently processed. Intra hepatic shunt index in cirrhotics was significantly different from the IPH group. Extra hepatic shunt index, however, was not significantly different in the two groups but was related more to the severity of the disease process. Spleno hepatic and spleno cardiac transit times were significantly lower cirrhotics as compared to the IPH group. We conclude that SSP is a technically simple, rapid and a much less invasive method of visualizing the portal circulatory system and assessing the portal haemo dynamics. it also provides clinically important measure of shunted blood nd allows for the quantification of circulatory time from spleen to liver and heart. (author)

  4. Privacy versus autonomy: a tradeoff model for smart home monitoring technologies.

    Science.gov (United States)

    Townsend, Daphne; Knoefel, Frank; Goubran, Rafik

    2011-01-01

    Smart homes are proposed as a new location for the delivery of healthcare services. They provide healthcare monitoring and communication services, by using integrated sensor network technologies. We validate a hypothesis regarding older adults' adoption of home monitoring technologies by conducting a literature review of articles studying older adults' attitudes and perceptions of sensor technologies. Using current literature to support the hypothesis, this paper applies the tradeoff model to decisions about sensor acceptance. Older adults are willing to trade privacy (by accepting a monitoring technology), for autonomy. As the information captured by the sensor becomes more intrusive and the infringement on privacy increases, sensors are accepted if the loss in privacy is traded for autonomy. Even video cameras, the most intrusive sensor type were accepted in exchange for the height of autonomy which is to remain in the home.

  5. Wireless remote radiation monitoring system (WRRMS). Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The Science Application International Corporation (SAIC) RadStar trademark wireless remote radiation monitoring system (WRRMS) is designed to provide real-time monitoring of the radiation dose to workers as they perform work in radiologically contaminated areas. WRRMS can also monitor dose rates in a room or area. The system uses radio-frequency communications to transmit dose readings from the wireless dosimeters worn by workers to a remote monitoring station that can be located out of the contaminated area. Each base station can monitor up to 16 workers simultaneously. The WRRMS can be preset to trigger both audible and visual alarms at certain dose rates. The alarms are provided to the worker as well as the base station operator. This system is particularly useful when workers are wearing personal protective clothing or respirators that make visual observation of their self-reading dosimeters (SRDs), which are typically used to monitor workers, more difficult. The base station is an IBM-compatible personal computer that updates and records information on individual workers every ten seconds. Although the equipment costs for this improved technology are higher than the SRDs (amortized at $2.54/hr versus $1.02/hr), total operational costs are actually less ($639/day versus $851/day). This is because the WRRMS requires fewer workers to be in the contaminated zone than the traditional (baseline) technology. There are also intangible benefits associated with improved worker safety and as low as reasonably achievable (ALARA) principles, making the WRRMS an attractive alternative to the baseline technology. The baseline technology measures only integrated dose and requires workers to check their own dosimeters manually during the task

  6. Wireless remote radiation monitoring system (WRRMS). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1998-12-01

    The Science Application International Corporation (SAIC) RadStar{trademark} wireless remote radiation monitoring system (WRRMS) is designed to provide real-time monitoring of the radiation dose to workers as they perform work in radiologically contaminated areas. WRRMS can also monitor dose rates in a room or area. The system uses radio-frequency communications to transmit dose readings from the wireless dosimeters worn by workers to a remote monitoring station that can be located out of the contaminated area. Each base station can monitor up to 16 workers simultaneously. The WRRMS can be preset to trigger both audible and visual alarms at certain dose rates. The alarms are provided to the worker as well as the base station operator. This system is particularly useful when workers are wearing personal protective clothing or respirators that make visual observation of their self-reading dosimeters (SRDs), which are typically used to monitor workers, more difficult. The base station is an IBM-compatible personal computer that updates and records information on individual workers every ten seconds. Although the equipment costs for this improved technology are higher than the SRDs (amortized at $2.54/hr versus $1.02/hr), total operational costs are actually less ($639/day versus $851/day). This is because the WRRMS requires fewer workers to be in the contaminated zone than the traditional (baseline) technology. There are also intangible benefits associated with improved worker safety and as low as reasonably achievable (ALARA) principles, making the WRRMS an attractive alternative to the baseline technology. The baseline technology measures only integrated dose and requires workers to check their own dosimeters manually during the task.

  7. Portal vein branching order helps in the recognition of anomalous right-sided round ligament: common features and variations in portal vein anatomy.

    Science.gov (United States)

    Yamashita, Rikiya; Yamaoka, Toshihide; Nishitai, Ryuta; Isoda, Hiroyoshi; Taura, Kojiro; Arizono, Shigeki; Furuta, Akihiro; Ohno, Tsuyoshi; Ono, Ayako; Togashi, Kaori

    2017-07-01

    This study aimed to evaluate the common features and variations of portal vein anatomy in right-sided round ligament (RSRL), which can help propose a method to detect and diagnose this anomaly. In this retrospective study of 14 patients with RSRL, the branching order of the portal tree was analyzed, with special focus on the relationship between the dorsal branch of the right anterior segmental portal vein (P A-D ) and the lateral segmental portal vein (P LL ), to determine the common features. The configuration of the portal vein from the main portal trunk to the right umbilical portion (RUP), the inclination of the RUP, and the number and thickness of the ramifications branching from the right anterior segmental portal vein (P A ) were evaluated for variations. In all subjects, the diverging point of the P A-D was constantly distal to that of the P LL . The portal vein configuration was I- and Z-shaped in nine and five subjects, respectively. The RUP was tilted to the right in all subjects. In Z-shaped subjects, the portal trunk between the branching point of the right posterior segmental portal vein and that of the P LL was tilted to the left in one subject and was almost parallel to the vertical plane in four subjects. Multiple ramifications were radially distributed from the P A in eight subjects, whereas one predominant P A-D branched from the P A in six subjects. Based on the diverging points of the P A-D and P LL , we proposed a three-step method for the detection and diagnosis of RSRL.

  8. Meaningful Use of a Confidential Adolescent Patient Portal.

    Science.gov (United States)

    Thompson, Lindsay A; Martinko, Thomas; Budd, Pamela; Mercado, Rebeccah; Schentrup, Anzeela M

    2016-02-01

    To design and evaluate the usage of an adolescent patient portal specifically adapted for adolescent health care needs that also satisfied institutional meaningful use guidelines regarding electronic health records. Key stakeholders at one academic health care center adopted an online portal and opted to designate a patient portal specifically for adolescents to maximize confidentiality in compliance with state privacy laws. This study analyzed aggregate electronic health record data of adolescents' (ages 12-17.9 years) uptake, usage, and functionality of this portal and compared it to parent portal usage for younger children (ages 0-11 years). Differences in means were calculated using paired t tests. The portal was used similarly between parents of young children and adolescents, with almost 1,000 enrollees in each group from September 1, 2012 to March 31, 2015. There were no gender differences in enrollment. Adolescents were less likely than parents of younger children to review appointments (73% vs. 85%), laboratory tests (67% vs. 79%), problem lists (40% vs. 78%), or allergies (45% vs. 77%, all p values adolescents sent 1,397 confidential messages. Institutional decisions for implementing meaningful use requirements can align with goals of adolescent health. Patient portals can enhance adolescent health care quality and adolescents readily use a confidential portal. Implementation of meaningful use requirements should be checked against adolescent health care needs to maximize confidentiality and promote health communication. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  9. Inpatient Portals for Hospitalized Patients and Caregivers: A Systematic Review.

    Science.gov (United States)

    Kelly, Michelle M; Coller, Ryan J; Hoonakker, Peter Lt

    2018-06-01

    Patient portals, web-based personal health records linked to electronic health records (EHRs), provide patients access to their healthcare information and facilitate communication with providers. Growing evidence supports portal use in ambulatory settings; however, only recently have portals been used with hospitalized patients. Our objective was to review the literature evaluating the design, use, and impact of inpatient portals, which are patient portals designed to give hospitalized patients and caregivers inpatient EHR clinical information for the purpose of engaging them in hospital care. Literature was reviewed from 2006 to 2017 in PubMed, Web of Science, CINALPlus, Cochrane, and Scopus to identify English language studies evaluating patient portals, engagement, and inpatient care. Data were analyzed considering the following 3 themes: inpatient portal design, use and usability, and impact. Of 731 studies, 17 were included, 9 of which were published after 2015. Most studies were qualitative with small samples focusing on inpatient portal design; 1 nonrandomized trial was identified. Studies described hospitalized patients' and caregivers' information needs and design recommendations. Most patient and caregiver participants in included studies were interested in using an inpatient portal, used it when offered, and found it easy to use and/or useful. Evidence supporting the role of inpatient portals in improving patient and caregiver engagement, knowledge, communication, and care quality and safety is limited. Included studies indicated providers had concerns about using inpatient portals; however, the extent to which these concerns have been realized remains unclear. Inpatient portal research is emerging. Further investigation is needed to optimally design inpatient portals to maximize potential benefits for hospitalized patients and caregivers while minimizing unintended consequences for healthcare teams. © 2017 Society of Hospital Medicine.

  10. Assessment of private hospital portals: A conceptual model

    Directory of Open Access Journals (Sweden)

    Mehdi Alipour-Hafezi

    2016-01-01

    Full Text Available Introduction: Hospital portals, as the first virtual entry, play an important role in connecting people with hospital and also presenting hospital virtual services. The main purpose of this article was to suggest a conceptual model to improve Tehran private hospital portals. The suggested model can be used by all the health portals that are in the same circumstances and all the health portals which are in progress. Method: This is a practical research, using evaluative survey research method. Research population includes all the private hospital portals in Tehran, 34 portals, and ten top international hospital portals. Data gathering tool used in this research was a researcher-made checklist including 14 criteria and 77 sub-criteria with their weight score. In fact, objective observation with the mentioned checklist was used to gather information. Descriptive statistics were used to analyze the data and tables and graphs were used to present the organized data. Also, data were analyzed using independent t-test. Conceptual modeling technique was used to design the model and demonstration method was used to evaluate the proposed model. In this regard, SPSS statistical software was used to perform the tests. Results:The comparative study between the two groups of portals, TPH and WTH, in the 14 main criteria showed that the value of t-test in contact information criteria was 0.862, portal page specification was -1.378, page design criteria -1.527, updating pages -0.322, general information and access roads -3.161, public services -7.302, patient services -4.154, patient data -8.703, research and education -9.155, public relationship -3.009, page technical specifications -4.726, telemedicine -7.488, pharmaceutical services -6.183, and financial services -2.782. Finally, the findings demonstrated that Tehran private hospital portals in criterion of contact information were favorable; page design criteria were relatively favorable; page technical

  11. Portal placement in elbow arthroscopy by novice surgeons: cadaver study.

    Science.gov (United States)

    Claessen, Femke M A P; Kachooei, Amir R; Kolovich, Gregory P; Buijze, Geert A; Oh, Luke S; van den Bekerom, Michel P J; Doornberg, Job N

    2017-07-01

    In this anatomical cadaver study, the distance between major nerves and ligaments at risk for injury and portal sites created by trainees was measured. Trainees, inexperienced in elbow arthroscopy, have received a didactic lecture and cadaver instruction prior to portal placement. The incidence of iatrogenic injury from novice portal placement was also determined. Anterolateral, direct lateral, and anteromedial arthroscopic portals were created in ten cadavers by ten inexperienced trainees in elbow arthroscopy. After creating each portal, the trajectory of the portal was marked with a guide pin. Subsequently, the cadavers were dissected and the distances between the guide pin in the anterolateral, direct lateral, and anteromedial portals and important ligaments and nerves were measured. The difference between the distance of the direct lateral portal and the posterior antebrachial cutaneous nerve (PABCN) (22 mm, p cadaver instruction session alone. Level of evidence V.

  12. Analysis of Land Subsidence Monitoring in Mining Area with Time-Series Insar Technology

    Science.gov (United States)

    Sun, N.; Wang, Y. J.

    2018-04-01

    Time-series InSAR technology has become a popular land subsidence monitoring method in recent years, because of its advantages such as high accuracy, wide area, low expenditure, intensive monitoring points and free from accessibility restrictions. In this paper, we applied two kinds of satellite data, ALOS PALSAR and RADARSAT-2, to get the subsidence monitoring results of the study area in two time periods by time-series InSAR technology. By analyzing the deformation range, rate and amount, the time-series analysis of land subsidence in mining area was realized. The results show that InSAR technology could be used to monitor land subsidence in large area and meet the demand of subsidence monitoring in mining area.

  13. Identifying How Patient Portals May Be Effectively Used Among Mental Health Populations to Support Digital Inclusion: A Study Protocol.

    Science.gov (United States)

    Strudwick, Gillian; Booth, Richard; Strauss, John

    2018-01-01

    Patient portals are secure online websites that allow patients access to their medical information from a particular healthcare organization. Currently, it is unknown how this technology can best be used to support patients with mental illness, and what types of indicators of portal adoption are meaningful to these patients. This study addresses this gap in our knowledge by obtaining the perspectives on this topic from patients, family members and Peer Support Workers.

  14. Beyond Self-Monitoring: Understanding Non-functional Aspects of Home-based Healthcare Technology

    DEFF Research Database (Denmark)

    Grönvall, Erik; Verdezoto, Nervo

    2013-01-01

    the appropriation of healthcare technologies and people with comorbidity may have diverse but co-existing monitoring needs. In this paper, we seek to understand home-based health monitoring practices to better design and integrate them into people’s everyday life. We perform an analysis of socio......-technical complexities in home-based healthcare technologies through three case studies of self-monitoring: 1) pre-eclampsia (i.e. pregnancy poisoning), 2) heart conditions, and 3) preventive care. Through the analysis seven themes emerged (people, resources, places, routines, knowledge, control and motivation) that can...... facilitate the understanding of home-based healthcare activities. We present three modes of self-monitoring use and provide a set of design recommendations for future Ubicomp designs of home-based healthcare technology....

  15. DOE/LLNL verification symposium on technologies for monitoring nuclear tests related to weapons proliferation

    International Nuclear Information System (INIS)

    Nakanishi, K.K.

    1993-01-01

    The rapidly changing world situation has raised concerns regarding the proliferation of nuclear weapons and the ability to monitor a possible clandestine nuclear testing program. To address these issues, Lawrence Livermore National Laboratory's (LLNL) Treaty Verification Program sponsored a symposium funded by the US Department of Energy's (DOE) Office of Arms Control, Division of Systems and Technology. The DOE/LLNL Symposium on Technologies for Monitoring Nuclear Tests Related to Weapons Proliferation was held at the DOE's Nevada Operations Office in Las Vegas, May 6--7,1992. This volume is a collection of several papers presented at the symposium. Several experts in monitoring technology presented invited talks assessing the status of monitoring technology with emphasis on the deficient areas requiring more attention in the future. In addition, several speakers discussed proliferation monitoring technologies being developed by the DOE's weapons laboratories

  16. Portal hypertension: a review of portosystemic collateral pathways and endovascular interventions

    International Nuclear Information System (INIS)

    Pillai, A.K.; Andring, B.; Patel, A.; Trimmer, C.; Kalva, S.P.

    2015-01-01

    The portal vein is formed at the confluence of the splenic and superior mesenteric vein behind the head of the pancreas. Normal blood pressure within the portal system varies between 5 and 10 mmHg. Portal hypertension is defined when the gradient between the portal and systemic venous blood pressure exceeds 5 mmHg. The most common cause of portal hypertension is cirrhosis. In cirrhosis, portal hypertension develops due to extensive fibrosis within the liver parenchyma causing increased vascular resistance. In addition, the inability of the liver to metabolise certain vasodilators leads to hyperdynamic splanchnic circulation resulting in increased portal blood flow. Decompression of the portal pressure is achieved by formation of portosystemic collaterals. In this review, we will discuss the pathophysiology, anatomy, and imaging findings of spontaneous portosystemic collaterals and clinical manifestations of portal hypertension with emphasis on the role of interventional radiology in the management of complications related to portal hypertension

  17. Portal Hypertension Secondary to Spontaneous Arterio-Portal Venous Fistulas: Transcatheter Arterial Embolization with n-Butyl Cyanoacrylate and Microcoils

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Nakamura, Toshiyuki; Nishimura, Tsunehiko

    2000-01-01

    We report a 73-year-old man with recurrent variceal bleeding due to portal hypertension caused by multiple intrahepatic arterio-portal venous fistulas, which were successfully occluded by embolization with n-butyl cyanoacrylate and micro-coils

  18. Novel Rat Model of Repetitive Portal Venous Embolization Mimicking Human Non-Cirrhotic Idiopathic Portal Hypertension.

    Science.gov (United States)

    Klein, Sabine; Hinüber, Christian; Hittatiya, Kanishka; Schierwagen, Robert; Uschner, Frank Erhard; Strassburg, Christian P; Fischer, Hans-Peter; Spengler, Ulrich; Trebicka, Jonel

    2016-01-01

    Non-cirrhotic idiopathic portal hypertension (NCIPH) is characterized by splenomegaly, anemia and portal hypertension, while liver function is preserved. However, no animal models have been established yet. This study assessed a rat model of NCIPH and characterized the hemodynamics, and compared it to human NCIPH. Portal pressure (PP) was measured invasively and coloured microspheres were injected in the ileocecal vein in rats. This procedure was performed weekly for 3 weeks (weekly embolization). Rats without and with single embolization served as controls. After four weeks (one week after last embolization), hemodynamics were investigated, hepatic fibrosis and accumulation of myofibroblasts were analysed. General characteristics, laboratory analyses and liver histology were collected in patients with NCIPH. Weekly embolization induced a hyperdynamic circulation, with increased PP. The mesenteric flow and hepatic hydroxyproline content was significantly higher in weekly embolized compared to single embolized rats (mesenteric flow +54.1%, hydroxyproline +41.7%). Mesenteric blood flow and shunt volumes increased, whereas splanchnic vascular resistance was decreased in the weekly embolization group. Fibrotic markers αSMA and Desmin were upregulated in weekly embolized rats. This study establishes a model using repetitive embolization via portal veins, comparable with human NCIPH and may serve to test new therapies.

  19. The Portals 4.1 Network Programming Interface

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian; Brightwell, Ronald B.; Grant, Ryan; Hemmert, Karl Scott; Pedretti, Kevin; Wheeler, Kyle; Underwood, Keith D; Riesen, Rolf; Maccabe, Arthur B.; Hudson, Trammel

    2017-04-01

    This report presents a specification for the Portals 4 networ k programming interface. Portals 4 is intended to allow scalable, high-performance network communication betwee n nodes of a parallel computing system. Portals 4 is well suited to massively parallel processing and embedded syste ms. Portals 4 represents an adaption of the data movement layer developed for massively parallel processing platfor ms, such as the 4500-node Intel TeraFLOPS machine. Sandia's Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4 is tar geted to the next generation of machines employing advanced network interface architectures that support enh anced offload capabilities.

  20. The Portals 4.0 network programming interface.

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin; Wheeler, Kyle Bruce; Hemmert, Karl Scott; Riesen, Rolf E.; Underwood, Keith Douglas; Maccabe, Arthur Bernard; Hudson, Trammell B.

    2012-11-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generation of machines employing advanced network interface architectures that support enhanced offload capabilities.

  1. Computed tomographic evaluation of the portal vein in the hepatomas

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1986-10-15

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  2. Computed tomographic evaluation of the portal vein in the hepatomas

    International Nuclear Information System (INIS)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam

    1986-01-01

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  3. A study of trans-rectal portal scintigraphy for the diagnostic evaluation of portal hypertension with hepatic cirrhosis

    International Nuclear Information System (INIS)

    Tang Mingdeng; Dong Weiyu; Liu Yonghua; He Pinyu; Li Zhener

    1996-01-01

    The portal hypertension of hepatic cirrhosis was studied by 99m Tc-MIBI trans-rectum imaging. The portal systemic circulation was evaluated by the heart-liver ratio (H/L ratio) and the portosystemic shunt index (SI). The H/L and SI in 12 normal cases were 0.145 +- 0.042 and 0.124 +- 0.029. Whereas in 18 patients with hepatobiliary diseases of non-cirrhosis were 0.207 +- 0.076 and 0.169 +- 0.051, and in 47 patients with hepatic cirrhosis were 0.751 +-0.313 and 0.422 +- 0.075. The results showed significant difference (P<0.01) between normal controls and non-cirrhosis group, and significant difference (P<0.001) between hepatic cirrhosis group and normal controls, non-cirrhosis group. A significant difference (P<0.05) in child-pugh's classification A, B and C groups was also found. A significant correlation (r = 0.95, P<0.01) with the H/L, SI and portal pressure measurement during operation was found. If H/L≥0.30, and SI≥0.22 were taken as positive criteria for diagnosis of portal hypertension with hepatic cirrhosis, the sensitivity, specificity and accuracy were 96%, 90% and 94% respectively. Therefore, it was a new method for the diagnosis of portal hypertension with hepatic cirrhosis

  4. Development of alpha radioactivity monitor using ionized air transport technology

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki

    2008-01-01

    A novel alpha radioactivity monitor using ionized air transport technology has been developed for future constitution of 'Clearance Level' for uranium and TRU radioactive waste. We carried out optimum design and realized two kinds of practical alpha activity monitor, combining with radiation detector technology, ionized air physics and computational fluid dynamics. The results will bring paradigm shift on the alpha-ray measurement such as converting 'closely contacting and scanning measurement' to 'remotely measurement in the block', and drastically improve the efficiency of measurement operation. We hope that this technology will be widely endorsed as the practical method for the alpha clearance measurement in future. (author)

  5. Focal spot motion of linear accelerators and its effect on portal image analysis

    International Nuclear Information System (INIS)

    Sonke, Jan-Jakob; Brand, Bob; Herk, Marcel van

    2003-01-01

    The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring portal images, this motion will affect the projected position of anatomy and field edges, especially when low exposures are used. In this paper, the motion of the focal spot and the effect of this motion on portal image analysis are quantified. A slightly tilted narrow slit phantom was placed at the isocenter of several linear accelerators and images were acquired (3.5 frames per second) by means of an amorphous silicon flat panel imager positioned ∼0.7 m below the isocenter. The motion of the focal spot was determined by converting the tilted slit images to subpixel accurate line spread functions. The error in portal image analysis due to focal spot motion was estimated by a subtraction of the relative displacement of the projected slit from the relative displacement of the field edges. It was found that the motion of the focal spot depends on the control system and design of the accelerator. The shift of the focal spot at the start of irradiation ranges between 0.05-0.7 mm in the gun-target (GT) direction. In the left-right (AB) direction the shift is generally smaller. The resulting error in portal image analysis due to focal spot motion ranges between 0.05-1.1 mm for a dose corresponding to two monitor units (MUs). For 20 MUs, the effect of the focal spot motion reduces to 0.01-0.3 mm. The error in portal image analysis due to focal spot motion can be reduced by reducing the applied dose rate

  6. Portal Annular Pancreas

    Science.gov (United States)

    Harnoss, Jonathan M.; Harnoss, Julian C.; Diener, Markus K.; Contin, Pietro; Ulrich, Alexis B.; Büchler, Markus W.; Schmitz-Winnenthal, Friedrich H.

    2014-01-01

    Abstract Portal annular pancreas (PAP) is an asymptomatic congenital pancreas anomaly, in which portal and/or mesenteric veins are encased by pancreas tissue. The aim of the study was to determine the role of PAP in pancreatic surgery as well as its management and potential complication, specifically, postoperative pancreatic fistula (POPF). On the basis of a case report, the MEDLINE and ISI Web of Science databases were systematically reviewed up to September 2012. All articles describing a case of PAP were considered. In summary, 21 studies with 59 cases were included. The overall prevalence of PAP was 2.4% and the patients' mean (SD) age was 55.9 (16.2) years. The POPF rate in patients with PAP (12 pancreaticoduodenectomies and 3 distal pancreatectomies) was 46.7% (in accordance with the definition of the International Study Group of Pancreatic Surgery). Portal annular pancreas is a quite unattended pancreatic variant with high prevalence and therefore still remains a clinical challenge to avoid postoperative complications. To decrease the risk for POPF, attentive preoperative diagnostics should also focus on PAP. In pancreaticoduodenectomy, a shift of the resection plane to the pancreas tail should be considered; in extensive pancreatectomy, coverage of the pancreatic remnant by the falciform ligament could be a treatment option. PMID:25207658

  7. Structure health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok

    2003-01-01

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  8. Structural health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok [Nonstructive Measurment Lab., KRISS, Daejeon (Korea, Republic of)

    2003-07-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  9. Structure health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok [Smart Measurment Group. Korea Resarch Institute of Standards and Science, Saejeon (Korea, Republic of)

    2003-05-15

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  10. Structural health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok

    2003-01-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  11. Base of tongue varices associated with portal hypertension

    OpenAIRE

    Jassar, P; Jaramillo, M; Nunez, D

    2000-01-01

    A symptomatic case of tongue base varices in a patient with portal hypertension secondary to liver cirrhosis is presented. There are no previously documented cases in the world literature. Oesophageal varices may not be the only source of expectorated blood in a patient with portal hypertension.


Keywords: portal hypertension; lingual; tongue; varicose vein

  12. Transsinusoidal Portal Vein Embolization with Ethylene Vinyl Alcohol Copolymer (Onyx): A Feasibility Study in Pigs

    Energy Technology Data Exchange (ETDEWEB)

    Smits, Maarten L. J., E-mail: m.l.j.smits-3@umcutrecht.nl [University Medical Center Utrecht, Department of Radiology (Netherlands); Vanlangenhove, Peter, E-mail: peter.vanlangenhove@uzgent.be; Sturm, Emiel J. C., E-mail: ejcsturm@gmail.com [Ghent University Hospital, Department of Vascular and Interventional Radiology (Belgium); Bosch, Maurice A. A. J. van den, E-mail: mbosch@umcutrecht.nl [University Medical Center Utrecht, Department of Radiology (Netherlands); Hav, Monirath, E-mail: hav.monirath@gmail.com; Praet, Marleen, E-mail: marleen.praet@ugent.be [Ghent University Hospital, N. Goormaghtigh Institute of Pathology (Belgium); Vente, Maarten A. D., E-mail: m.vente@umcutrecht.nl [University Medical Center Utrecht, Department of Radiology (Netherlands); Snaps, Frederic R., E-mail: fsnaps@ulg.ac.be [University of Liege, Department of Clinical Sciences, Faculty of Veterinary Medicine (Belgium); Defreyne, Luc, E-mail: luc.defreyne@ugent.be [Ghent University Hospital, Department of Vascular and Interventional Radiology (Belgium)

    2012-10-15

    Purpose: Portal vein embolization is performed to increase the future liver remnant before liver surgery in patients with liver malignancies. This study assesses the feasibility of a transsinusoidal approach for portal vein embolization (PVE) with the ethylene vinyl alcohol copolymer, Onyx. Methods: Indirect portography through contrast injection in the cranial mesenteric artery was performed in eight healthy pigs. Onyx was slowly injected through a microcatheter from a wedged position in the hepatic vein and advanced through the liver lobules into the portal system. The progression of Onyx was followed under fluoroscopy, and the extent of embolization was monitored by indirect portography. The pigs were euthanized immediately (n = 2), at 7 days (n = 4), or at 21 days postprocedure (n = 2). All pigs underwent necropsy and the ex vivo livers were grossly and histopathologically analyzed. Results: Transsinusoidal PVE was successfully performed in five of eight pigs (63%). In 14 of 21 injections (67%), a segmental portal vein could be filled completely. A mean of 1.6 liver lobes per pig was embolized (range 1-2 lobes). There were no periprocedural adverse events. Focal capsular scarring was visible on the surface of two resected livers, yet the capsules remained intact. Histopathological examination showed no signs of recanalization or abscess formation. Mild inflammatory reaction to Onyx was observed in the perivascular parenchyma. Conclusions: The porcine portal vein can be embolized through injection of Onyx from a wedged position in the hepatic vein. Possible complications of transsinusoidal PVE and the effect on contralateral hypertrophy need further study.

  13. Racial/ethnic variation in devices used to access patient portals.

    Science.gov (United States)

    Chang, Eva; Blondon, Katherine; Lyles, Courtney R; Jordan, Luesa; Ralston, James D

    2018-01-01

    We examined racial/ethnic variation in the devices used by patients to access medical records through an online patient portal. Retrospective, cross-sectional analysis. Using data from 318,700 adults enrolled in an integrated delivery system between December 2012 and November 2013, we examined: 1) online patient portal use that directly engages the electronic health record and 2) portal use over desktops/laptops only, mobile devices only, or both device types. The primary covariate was race/ethnicity (non-Hispanic white, black, Hispanic, and Asian). Other covariates included age, sex, primary language, and neighborhood-level income and education. Portal use and devices used were assessed with multiple and multinomial logistic models, respectively. From December 2012 to November 2013, 56% of enrollees used the patient portal. Of these portal users, 62% used desktops/laptops only, 6% used mobile devices only, and 32% used both desktops/laptops and mobile devices. Black, Hispanic, and Asian enrollees had significantly lower odds of portal use than whites. Black and Hispanic portal users also were significantly more likely to use mobile devices only (relative risk ratio, 1.73 and 1.44, respectively) and both device types (1.21 and 1.07, respectively) than desktops/laptops only compared with whites. Although racial/ethnic minority enrollees were less likely to access the online patient portal overall, a greater proportion of black and Hispanic users accessed the patient portal with mobile devices than did non-Hispanic white users. The rapid spread of mobile devices among racial/ethnic minorities may help reduce variation in online patient portal use. Mobile device use may represent an opportunity for healthcare organizations to further engage black and Hispanic enrollees in online patient portal use.

  14. Portal-venous gas unrelated to mesenteric ischemia

    International Nuclear Information System (INIS)

    Wiesner, Walter; Mortele, Koenraad J.; Ji, Hoon; Ros, Pablo R.; Glickman, Jonathan N.

    2002-01-01

    The aim of this study was to report on 8 patients with all different non-ischemic etiologies for portal-venous gas and to discuss this rare entity and its potentially misleading CT findings in context with a review of the literature. The CT examinations of eight patients who presented with intrahepatic portal-venous gas, unrelated to bowel ischemia or infarction, were reviewed and compared with their medical records with special emphasis on the pathogenesis and clinical impact of portal-venous gas caused by non-ischemic conditions. The etiologies for portal-venous gas included: abdominal trauma (n=1); large gastric cancer (n=1); prior gastroscopic biopsy (n=1); prior hemicolectomy (n=1); graft-vs-host reaction (n=1); large paracolic abscess (n=1); mesenteric recurrence of ovarian cancer superinfected with clostridium septicum (n=1); and sepsis with Pseudomonas aeruginosa (n=1). The clinical outcome of all patients was determined by their underlying disease and not negatively influenced by the presence of portal-venous gas. Although the presence of portal-venous gas usually raises the suspicion of bowel ischemia and/or intestinal necrosis, this CT finding may be related to a variety of non-ischemic etiologies and pathogeneses as well. The knowledge about these conditions may help to avoid misinterpretation of CT findings, inappropriate clinical uncertainty and unnecessary surgery in certain cases. (orig.)

  15. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites

  16. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.

  17. Analysis of Dynamic Characteristics of Portal Frame with Variable Section

    OpenAIRE

    Hao Jianing

    2016-01-01

    Combined with a portal frame design, by the use of finite element software ANSYS, the finite element model of single specimens of portal rigid frame and the overall portal rigid frame building are established. portal rigid frame’s beam and column is variable cross section. Through the modal analysis, comparative analysis of the frequency and vibration type of the radiolabeling specimens and finite element model of the whole, for the further development of variable cross-section portal rigid f...

  18. A user-oriented model for global enterprise portal design

    NARCIS (Netherlands)

    Feng, X.; Ehrenhard, Michel Léon; Hicks, Jeff; Maathuis, Stephanus Johannes; Maathuis, S.J.; Hou, Y.

    2010-01-01

    Enterprise portals collect and synthesise information from various systems to deliver personalised and highly relevant information to users. Enterprise portals' design and applications are widely discussed in the literature; however, the implications of portal design in a global networked

  19. Portfolio: a prototype workstation for development and evaluation of tools for analysis and management of digital portal images

    International Nuclear Information System (INIS)

    Boxwala, Aziz A.; Chaney, Edward L.; Fritsch, Daniel S.; Friedman, Charles P.; Rosenman, Julian G.

    1998-01-01

    Purpose: The purpose of this investigation was to design and implement a prototype physician workstation, called PortFolio, as a platform for developing and evaluating, by means of controlled observer studies, user interfaces and interactive tools for analyzing and managing digital portal images. The first observer study was designed to measure physician acceptance of workstation technology, as an alternative to a view box, for inspection and analysis of portal images for detection of treatment setup errors. Methods and Materials: The observer study was conducted in a controlled experimental setting to evaluate physician acceptance of the prototype workstation technology exemplified by PortFolio. PortFolio incorporates a windows user interface, a compact kit of carefully selected image analysis tools, and an object-oriented data base infrastructure. The kit evaluated in the observer study included tools for contrast enhancement, registration, and multimodal image visualization. Acceptance was measured in the context of performing portal image analysis in a structured protocol designed to simulate clinical practice. The acceptability and usage patterns were measured from semistructured questionnaires and logs of user interactions. Results: Radiation oncologists, the subjects for this study, perceived the tools in PortFolio to be acceptable clinical aids. Concerns were expressed regarding user efficiency, particularly with respect to the image registration tools. Conclusions: The results of our observer study indicate that workstation technology is acceptable to radiation oncologists as an alternative to a view box for clinical detection of setup errors from digital portal images. Improvements in implementation, including more tools and a greater degree of automation in the image analysis tasks, are needed to make PortFolio more clinically practical

  20. Noncirrhotic portal fibrosis after Wilms' tumor therapy

    International Nuclear Information System (INIS)

    Barnard, J.A.; Marshall, G.S.; Neblett, W.W.; Gray, G.; Ghishan, F.K.

    1986-01-01

    A 9-yr-old girl developed massive hemorrhage from esophageal varices 2 yr after combined modality therapy for Wilms' tumor. Evaluation showed a patent extrahepatic portal venous system and an elevated splenic pulp pressure. In contrast to previous reports of hepatopathy after irradiation injury, histologic sections of the liver did not demonstrate occlusion of the central veins, but rather a diffuse obliteration of intrahepatic portal venous radicles. This pattern of noncirrhotic portal fibrosis has not been described following antitumor therapy

  1. Portal circulation aneurysms: two case reviews

    International Nuclear Information System (INIS)

    Perret, W. L.; Silva, A de.; Elzarka, A.; Schelleman, A.

    2007-01-01

    Venous aneurysms of the superior mesenteric vein and portal vein are an uncommon occurrence and often an incidental finding. They can also be associated with hepatocellular disease and portal hypertension. We present CT and ultrasound findings of these entities. The management of venous aneurysms is generally conservative with serial imaging

  2. Editor's welcome, PORTAL, Vol. 4, No. 2, July 2007

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2007-10-01

    Full Text Available The second issue of PORTAL Journal of Multidisciplinary International Studies for 2007 is a special issue with the title Contesting Euro Visions, guest edited by Dimitris Eleftheriotis (University of Glasgow, Murray Pratt (University of Technology Sydney and Ilaria Vanni, (University of Technology Sydney. As the editors’ opening essay emphasises, this issue is not concerned to perpetuate myths of a Europe united or federated, or even cohered by shared values. Rather, it aims to reclaim something of the conceptual, transcultural and locational uncertainties encoded in the foundation myth of Europe’s origins: Europa’s seduction and abduction by Zeus, disguised as a white bull. As the editors argue, this myth is marked by the physical elusiveness of Europe’s actual location (Homer’s Europa being, for example, Phoenician, in what is now Syria, and also complicated by centuries of amendments and revisions. Thus, by approaching contemporary Europe through the prism of a mutating and unanchored foundational fiction, the editors argue that that fiction ‘can be used to understand how in Europe particular local histories and local knowledge intersect with global issues, and conversely how what appears to be “European” is, in fact, the result of global encounters. Narratives of European values need to be located in this striated space, while friction as an organising metaphor also explains the slippage and relation between the lived, heterogeneous embodiments of contemporary Europe and abstract notions of values.’ The other essays gathered in this special issue endorse this notion of a striated Europe, a shifting space best regarded as a space of friction. I would like to thank all of the authors included in this special issue for their patience, and their support for the Contesting Euro Visions ideal that frames the issue. I would also like to take the opportunity to announce a call for papers for the July 2008 issue of PORTAL

  3. Portal hypertension: a review of portosystemic collateral pathways and endovascular interventions.

    Science.gov (United States)

    Pillai, A K; Andring, B; Patel, A; Trimmer, C; Kalva, S P

    2015-10-01

    The portal vein is formed at the confluence of the splenic and superior mesenteric vein behind the head of the pancreas. Normal blood pressure within the portal system varies between 5 and 10 mmHg. Portal hypertension is defined when the gradient between the portal and systemic venous blood pressure exceeds 5 mmHg. The most common cause of portal hypertension is cirrhosis. In cirrhosis, portal hypertension develops due to extensive fibrosis within the liver parenchyma causing increased vascular resistance. In addition, the inability of the liver to metabolise certain vasodilators leads to hyperdynamic splanchnic circulation resulting in increased portal blood flow. Decompression of the portal pressure is achieved by formation of portosystemic collaterals. In this review, we will discuss the pathophysiology, anatomy, and imaging findings of spontaneous portosystemic collaterals and clinical manifestations of portal hypertension with emphasis on the role of interventional radiology in the management of complications related to portal hypertension. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Building an Open Data Portal for the European Space Agency Climate Change Initiative based on an Iterative Development Methodology and Linked Data Technologies

    Science.gov (United States)

    Kershaw, P.; Bennett, V. L.; Stephens, A.; Wilson, A.; Waterfall, A. M.; Petrie, R.; Iwi, A.; Donegan, S.; Juckes, M. N.; Parton, G.

    2016-12-01

    The Climate Change Initiative (CCI) programme was initiated by the European Space Agency (ESA) in 2009 to address the GCOS Essential Climate Variable (ECV) requirements to provide stable, long-term, satellite-based data products to characterise the climate system and its changes. CEDA, working as part of a project consortium, were awarded the contract to build the Open Data Portal, consisting collectively of a central archive and single point of access for dissemination of the data to the international user community. Reflecting climate and earth observation community requirements, the system needed to support a range of access services in use by this domain and specifically, to integrate into existing infrastructure in the form of the Earth System Grid Federation (ESGF). This range of requirements together with the heterogeneity of the ECV datasets presented significant challenges. However, the use of Linked Data technologies and an iterative approach to data model development and data publishing have been instrumental in meeting the objectives and building a cohesive system. The portal supports data discovery based on the OGC CSW specification and on ESGF's powerful faceted search. These services provide complementary content at different levels of granularity and it therefore became clear that a common data model was needed. Key terms are defined in vocabularies serialised in SKOS and OWL and are accessible from a central vocabulary server to provide a single authoritative source for applications consuming metadata content. Exploiting the vocabulary service therefore, it has been possible to develop an innovative solution tagging ISO 19115 records for the CSW with the equivalent vocabulary terms used for the ESGF faceted search system. In this way it has been possible to create a rich user interface for the portal combining search results from both search services and the ability to dynamically populate facet selection and context-based help information from the

  5. A case of uneventful early post partum phase of pregnancy with LSCS in a known case of portal hypertension with splenectomy & a delayed peritonitis.

    Directory of Open Access Journals (Sweden)

    Dr. Dhruvkumar Baru

    2017-06-01

    Full Text Available This is a case of 32 year old multigravida, a known case of portal hypertension with episodes of haemetemesis on and off since last 12 years with history of splenectomy 2.5 years ago with uneventful 1st LSCS presented with pain abdomen and abdominal distension post- LSCS. Blood investigations showed microcytic anaemia corrected by blood transfusion while hypo -proteinemia by FFP transfusion. USG showed portal vein thrombosis with ascites. CT scan was done which confirmed signs of portal hypertension with cavernoma formation and gross ascites, Fluid cytology suggestive of PMN's. Patient was managed by controlled tapping and fluid monitoring along with appropriate antibiotics.

  6. Autonomous Radiation Monitoring of Small Vessels

    International Nuclear Information System (INIS)

    Fabris, Lorenzo; Hornback, Donald Eric

    2010-01-01

    Small private vessels are one avenue by which nuclear materials may be smuggled across international borders. While one can contemplate using the terrestrial approach of radiation portal monitors on the navigable waterways that lead to many ports, these systems are ill-suited to the problem. They require vehicles to pass at slow speeds between two closely-spaced radiation sensors, relying on the uniformity of vehicle sizes to space the detectors, and on proximity to link an individual vehicle to its radiation signature. In contrast to roadways where lanes segregate vehicles, and motion is well controlled by inspection booths; channels, inlets, and rivers present chaotic traffic patterns populated by vessels of all sizes. We have developed a unique solution to this problem based on our portal-less portal monitor instrument that is designed to handle free-flowing traffic on roadways with up to five-traffic lanes. The instrument uses a combination of visible-light and gamma-ray imaging to acquire and link radiation images to individual vehicles. It was recently tested in a maritime setting. In this paper we present the instrument, how it functions, and the results of the recent tests.

  7. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    International Nuclear Information System (INIS)

    Burcharth, F.; Aagaard, J.; Herlev Hospital

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P [de

  8. Modified Anterolateral Portals in Elbow Arthroscopy: A Cadaveric Study on Safety.

    Science.gov (United States)

    Thon, Stephen; Gold, Peter; Rush, Lane; O'Brien, Michael J; Savoie, Felix H

    2017-11-01

    To evaluate the proximity to the radial nerve on cadaveric specimens of 2 modified anterolateral portals used for elbow arthroscopy. Ten fresh cadaveric elbow specimens were prepared. Four-millimeter Steinman pins were inserted into 3 anterolateral portal sites in relation to the lateral epicondyle: (1) the standard distal anterolateral portal, (2) a modified direct anterolateral portal, and (3) a modified proximal anterolateral portal. These were defined as follows: direct portals 2 cm directly anterior to the lateral epicondyle, and proximal portals 2 cm proximal and 2 cm directly anterior to the lateral epicondyle. Each elbow was then dissected to reveal the course of the radial nerve. Digital photographs were taken of each specimen, and the distance from the Steinman pin to the radial nerve was measured. The modified proximal anterolateral and direct anterolateral portals were found to be a statistically significant distance from the radial nerve compare to the distal portal site (P = .011 and P = .0011, respectively). No significant difference was found in the proximity of the radial nerve between the modified proximal and direct anterolateral portals (P = .25). Inadequate imaging was found at a single portal site for the proximal site; 9 specimens were used for analysis of this portal with 10 complete specimens for the other 2 sites. In cadaveric analysis, both the modified proximal and direct lateral portals provide adequate distance from the radial nerve and may be safe for clinical use. In this study, the distal anterolateral portal was in close proximity of the radial nerve and may result in iatrogenic injury in the clinical setting. This is a cadaveric analysis of 2 modified portal locations at the anterolateral elbow for use in elbow arthroscopy. Further clinical studies are needed prior to determining their absolute safety in comparison to previously identified portal sites. Copyright © 2017 Arthroscopy Association of North America. Published by

  9. Factors Affecting Faculty Web Portal Usability

    Science.gov (United States)

    Bringula, Rex P.; Basa, Roselle S.

    2011-01-01

    The study investigated the factors that might significantly affect web portal usability. Results of the study were intended to serve as inputs for faculty web portal development of the University of the East-Manila. Descriptive statistics utilized questionnaire data from 82 faculty members. The data showed that most of the respondents were…

  10. Leak detection, monitoring, and mitigation technology trade study update

    International Nuclear Information System (INIS)

    HERTZEL, J.S.

    1998-01-01

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful

  11. Leak detection, monitoring, and mitigation technology trade study update

    Energy Technology Data Exchange (ETDEWEB)

    HERTZEL, J.S.

    1998-11-10

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful.

  12. Algorithms for contrast enhancement of electronic portal images

    International Nuclear Information System (INIS)

    Díez, S.; Sánchez, S.

    2015-01-01

    An implementation of two new automatized image processing algorithms for contrast enhancement of portal images is presented as suitable tools which facilitate the setup verification and visualization of patients during radiotherapy treatments. In the first algorithm, called Automatic Segmentation and Histogram Stretching (ASHS), the portal image is automatically segmented in two sub-images delimited by the conformed treatment beam: one image consisting of the imaged patient obtained directly from the radiation treatment field, and the second one is composed of the imaged patient outside it. By segmenting the original image, a histogram stretching can be independently performed and improved in both regions. The second algorithm involves a two-step process. In the first step, a Normalization to Local Mean (NLM), an inverse restoration filter is applied by dividing pixel by pixel a portal image by its blurred version. In the second step, named Lineally Combined Local Histogram Equalization (LCLHE), the contrast of the original image is strongly improved by a Local Contrast Enhancement (LCE) algorithm, revealing the anatomical structures of patients. The output image is lineally combined with a portal image of the patient. Finally the output images of the previous algorithms (NLM and LCLHE) are lineally combined, once again, in order to obtain a contrast enhanced image. These two algorithms have been tested on several portal images with great results. - Highlights: • Two Algorithms are implemented to improve the contrast of Electronic Portal Images. • The multi-leaf and conformed beam are automatically segmented into Portal Images. • Hidden anatomical and bony structures in portal images are revealed. • The task related to the patient setup verification is facilitated by the contrast enhancement then achieved.

  13. Editor's welcome, PORTAL, Vol. 4, No. 1, January 2007

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2007-01-01

    Full Text Available PORTAL Journal of Multidisciplinary International Studies enters its fourth year with the journal’s first special Chinese-language issue. Organised under the rubric of ‘The Revival of Chinese Cultural Nationalism,’ the issue has been guest edited by Dr Yingjie Guo of the Institute for International Studies, University of Technology Sydney, and features the work of scholars based in China and Australia. As Guo says in his introductory essay to the special issue, debates over cultural nationalism in China have been on the rise since the events in Tiananmen Square on June 4, 1989; indeed, the post-Tiananmen era in China may be witnessing what Guo calls an unparalleled cultural-political movement in the country’s history. The various contributors to this special issue explore the ramifications and manifestations of that broad cultural-political movement in film production, television drama, literary texts, cultural essays, regional entrepreneurship, and contemporary debates on nationalism and liberalism. This issue of PORTAL also features four non-special issue essays: a study of feminist ethics in the work of Filipino-Australian writer and dramatist Merlinda Bobis, by Dolores Herrero (Universidad de Zaragoza, Spain; a taut critique of the discourse that regards the twentieth century as the bloodiest and most atrocious in human history, by David B. MacDonald (Otago University, New Zealand; a trenchant analysis, by Ramzi Nasser and Kamal Abouchedid (Notre Dame University, Lebanon, of what the authors call the rise of “academic apartheid” in the university sector throughout the Arab world; and a fascinating exploration of the feminism and environmentalism pioneered by the Australian author, mountaineer, solicitor and Buddhist Marie Byles (1900-1979, by Allison Cadzow (University of Technology Sydney. Finally, it is a huge pleasure to also include in PORTAL’s cultural works section a selection of poems by the Chinese poet Yang Lian

  14. BioPortal: An Open-Source Community-Based Ontology Repository

    Science.gov (United States)

    Noy, N.; NCBO Team

    2011-12-01

    Advances in computing power and new computational techniques have changed the way researchers approach science. In many fields, one of the most fruitful approaches has been to use semantically aware software to break down the barriers among disparate domains, systems, data sources, and technologies. Such software facilitates data aggregation, improves search, and ultimately allows the detection of new associations that were previously not detectable. Achieving these analyses requires software systems that take advantage of the semantics and that can intelligently negotiate domains and knowledge sources, identifying commonality across systems that use different and conflicting vocabularies, while understanding apparent differences that may be concealed by the use of superficially similar terms. An ontology, a semantically rich vocabulary for a domain of interest, is the cornerstone of software for bridging systems, domains, and resources. However, as ontologies become the foundation of all semantic technologies in e-science, we must develop an infrastructure for sharing ontologies, finding and evaluating them, integrating and mapping among them, and using ontologies in applications that help scientists process their data. BioPortal [1] is an open-source on-line community-based ontology repository that has been used as a critical component of semantic infrastructure in several domains, including biomedicine and bio-geochemical data. BioPortal, uses the social approaches in the Web 2.0 style to bring structure and order to the collection of biomedical ontologies. It enables users to provide and discuss a wide array of knowledge components, from submitting the ontologies themselves, to commenting on and discussing classes in the ontologies, to reviewing ontologies in the context of their own ontology-based projects, to creating mappings between overlapping ontologies and discussing and critiquing the mappings. Critically, it provides web-service access to all its

  15. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  16. Radionuclide splenoportography in patients with portal hypertension

    International Nuclear Information System (INIS)

    Kuriya, Kouji; Nagamachi, Shigeki; Hoshi, Hiroaki; Ohnishi, Takashi; Jinnouchi, Masashi; Futami, Sigemi; Yoshida, Akira; Watanabe, Katsuji

    1991-01-01

    Splenoportography using 99m Tc-pertechnetate was performed in 18 patients with portal hypertension. 99m Tc pertechnetate (370 MBq) was directly injected into the spleen. Co-lateral circulation of portal vein was observed in 13 of 18 patients (72%). L/H ratio was also calculated by the time activity curve of dynamic images. L/H ratio was significantly lower (p<0.05) in patients with colateral vessels and severe esophageal varix. Radionuclide splenography was an useful method for evaluating hemodynamics of portal vein. (author)

  17. Middleware and Web Services for the Collaborative Information Portal of NASA's Mars Exploration Rovers Mission

    Science.gov (United States)

    Sinderson, Elias; Magapu, Vish; Mak, Ronald

    2004-01-01

    We describe the design and deployment of the middleware for the Collaborative Information Portal (CIP), a mission critical J2EE application developed for NASA's 2003 Mars Exploration Rover mission. CIP enabled mission personnel to access data and images sent back from Mars, staff and event schedules, broadcast messages and clocks displaying various Earth and Mars time zones. We developed the CIP middleware in less than two years time usins cutting-edge technologies, including EJBs, servlets, JDBC, JNDI and JMS. The middleware was designed as a collection of independent, hot-deployable web services, providing secure access to back end file systems and databases. Throughout the middleware we enabled crosscutting capabilities such as runtime service configuration, security, logging and remote monitoring. This paper presents our approach to mitigating the challenges we faced, concluding with a review of the lessons we learned from this project and noting what we'd do differently and why.

  18. Barriers and Facilitators Affecting Patient Portal Implementation from an Organizational Perspective: Qualitative Study.

    Science.gov (United States)

    Kooij, Laura; Groen, Wim G; van Harten, Wim H

    2018-05-11

    The number of patient portals is rising, and although portals can have positive effects, their implementation has major impacts on the providing health care institutions. However, little is known about the organizational factors affecting successful implementation. Knowledge of the specific barriers to and facilitators of various stakeholders is likely to be useful for future implementations. The objective of this study was to identify the barriers to and facilitators of patient portal implementation facing various stakeholders within hospital organizations in the Netherlands. Purposive sampling was used to select hospitals of various types. A total of 2 university medical centers, 3 teaching hospitals, and 2 general hospitals were included. For each, 3 stakeholders were interviewed: (1) medical professionals, (2) managers, and (3) information technology employees. In total, 21 semistructured interviews were conducted using the Grol and Wensing model, which describes barriers to and facilitators of change in health care practice at 6 levels: (1) innovation; (2) individual professional; (3) patient; (4) social context; (5) organizational context; and (6) economic and political context. Two researchers independently selected and coded quotes by applying this model using a (deductive) directed content approach. Additional factors related to technical and portal characteristics were added using the model of McGinn et al, developed for implementation of electronic health records. In total, we identified 376 quotes, 26 barriers, and 28 facilitators. Thirteen barriers and 12 facilitators were common for all stakeholder groups. The facilitators' perceived usefulness (especially less paperwork) was mentioned by all the stakeholders, followed by subjects' positive attitude. The main barriers were lack of resources (namely, lack of staff and materials), financial difficulties (especially complying with high costs, lack of reimbursements), and guaranteeing privacy and security

  19. Management of Portal Hypertension After Liver Transplantation.

    Science.gov (United States)

    Korda, D; Deák, P Á; Kiss, G; Gerlei, Z; Kóbori, L; Görög, D; Fehérvári, I; Piros, L; Máthé, Z; Doros, A

    2017-09-01

    Post-transplantation portal hypertension has severe complications, such as esophageal varix bleeding, therapy refractory ascites, extreme splenomegaly, and graft dysfunction. The aim of our study was to analyze the effectiveness of the therapeutic strategies and how to visualize the procedure. A retrospective study involving liver transplantation patients from the Semmelweis University Department of Transplantation and Surgery was performed between 2005 and 2015. The prevalence, etiology, and leading complications of the condition were determined. The applied interventions' effects on the patients' ascites volume, splenic volume, and the occurrence of variceal bleeding were determined. Mean portal blood flow velocity and congestion index values were calculated using Doppler ultrasonography. The prevalence of post-transplantation portal hypertension requiring intervention was 2.8%. The most common etiology of the disease was portal anastomotic stenosis. The most common complications were esophageal varix bleeding and therapy refractory ascites. The patients' ascites volume decreased significantly (2923.3 ± 1893.2 mL vs. 423.3 ± 634.3 mL; P portal hypertension. After the interventions, these parameters shifted towards the physiologic ranges. The interventions performed in our clinic were effective in most cases. The patients' ascites volume, splenic volume, and the prevalence of variceal bleeding decreased after the treatment. Doppler ultrasonography has proved to be a valuable imaging modality in the diagnosis and the follow-up of post-transplantation portal hypertension. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Research advances in non-cirrhotic portal hypertension

    Directory of Open Access Journals (Sweden)

    ZHANG Bojing

    2016-02-01

    Full Text Available Although liver cirrhosis is the most common cause of portal hypertension (PH, about 20% of PH cases are caused by non-cirrhotic reasons, which are referred to as non-cirrhotic portal hypertension (NCPH, with a high incidence rate in developing countries. NCPH is a group of heterogeneous hepatic vascular diseases, including idiopathic portal hypertension (IPH and extrahepatic portal vein obstruction (EHPVO, as well as the rare diseases in clinical practice such as Budd-Chiari syndrome, congenital hepatic fibrosis, and nodular regenerative hyperplasia. The patients with NCPH usually have the symptoms of portal hypertension, such as recurrent variceal bleeding and splenomegaly, but liver function is well preserved in these patients. At present, the diagnosis of NCPH lacks a universally accepted standard and remains a challenge. In clinical practice, the method of exclusion is usually applied for the diagnosis of HCPH, and liver biopsy is performed when necessary to make a confirmed diagnosis. This paper introduces the pathogenesis and pathological manifestations of IPH and EHPVO, as well as the selection of diagnostic methods and therapeutic strategies. If upper gastrointestinal bleeding can be effectively controlled, NCPH is considered to have a relatively good prognosis.

  1. Analysis of Dynamic Characteristics of Portal Frame with Variable Section

    Directory of Open Access Journals (Sweden)

    Hao Jianing

    2016-01-01

    Full Text Available Combined with a portal frame design, by the use of finite element software ANSYS, the finite element model of single specimens of portal rigid frame and the overall portal rigid frame building are established. portal rigid frame’s beam and column is variable cross section. Through the modal analysis, comparative analysis of the frequency and vibration type of the radiolabeling specimens and finite element model of the whole, for the further development of variable cross-section portal rigid frame of earthquake and wind vibration analysis lay the foundation.

  2. Radionuclide assessment of portal hypertension syndrome

    International Nuclear Information System (INIS)

    Aliev, M.A.; Khusain, Sh.K.; Alpeisova, Sh.T.

    2005-01-01

    This paper presents review of radionuclide studies for portal hypertension patients. Presented results showed that portal hypertension signs were revealed for the first group patients. The signs become apparent by splenomegaly and increase of colloid accumulation in it. Accumulation of the chemical in spleen was evidence of ingestion rate increase of reticuloendothelial system owing to its hyperplasia as well as liver phagocytic activity decrease due to pathological paren-chematous process and inter liver blockade. The most typical scintigraphic signs of portal hypertension were determined according chemical accumulation decreased in spleen and marrow sequentially. It is determined radionuclide method contributes to assessment of structural and functional aberrations character in liver and spleen for cirrhosis patients. (author)

  3. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    Energy Technology Data Exchange (ETDEWEB)

    Burcharth, F; Aagaard, J

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P < 0.025). All patients with varices had bled. Half of the patients in the group with hepatofugal blood flow had a false splenoportographic diagnosis of portal vein thrombosis. In conclusion, total hepatofugal postal blood flow exists more often than hitherto assumed. Hepatofugal blood flow does not relieve portal hypertension nor prevent development of gastro-oesophageal varices or bleeding.

  4. [Association of biliary calculosis and portal cavernomatosis].

    Science.gov (United States)

    Crespi, C; De Giorgio, A M

    1992-08-01

    This paper reports the case of a woman, who underwent surgery because of cholelithiasis, with intraoperative finding of prehepatic portal hypertension from portal vein thrombosis ("portal cavernoma") with healthy liver, later confirmed by angiographic studies. This rare pathologic association carries a higher risk of major operative complications; therefore the Authors agree with the general belief that, for these cases, biliary tract surgery should be as simple and safe as possible. In the case of preoperative diagnosis of biliary disease associated with portal cavernoma, should a surgical approach on the biliary tract be required, we agree on the advisability of performing a shunting procedure before any kind of biliary surgery. In case of variceal bleeding endoscopic sclerotherapy will be the first choice; surgical procedures (shunting) should be seen as a second choice in case of rebleeding after sclerotherapy.

  5. Patient activation and use of an electronic patient portal.

    Science.gov (United States)

    Ancker, Jessica S; Osorio, Snezana N; Cheriff, Adam; Cole, Curtis L; Silver, Michael; Kaushal, Rainu

    2015-01-01

    Electronic patient portals give patients access to personal medical data, potentially creating opportunities to improve knowledge, self-efficacy, and engagement in healthcare. The combination of knowledge, self-efficacy, and engagement has been termed activation. Our objective was to assess the relationship between patient activation and outpatient use of a patient portal. Survey. A telephone survey was conducted with 180 patients who had been given access to a portal, 113 of whom used it and 67 of whom did not. The validated patient activation measure (PAM) was administered along with questions about demographics and behaviors. Portal users were no different from nonusers in patient activation. Portal users did have higher education level and more frequent Internet use, and were more likely to have precisely 2 prescription medications than to have more or fewer. Patients who chose to use an electronic patient portal were not more highly activated than nonusers, although they were more educated and more likely to be Internet users.

  6. A Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies.

    Science.gov (United States)

    Yu, Sung-Nien; Cheng, Jen-Chieh

    2005-01-01

    This paper proposes a wireless patient monitoring system which integrates Bluetooth and WiFi wireless technologies. A wireless portable multi-parameter device was designated to acquire physiological signals and transmit them to a local server via Bluetooth wireless technology. Four kinds of monitor units were designed to communicate via the WiFi wireless technology, including a local monitor unit, a control center, mobile devices (personal digital assistant; PDA), and a web page. The use of various monitor units is intending to meet different medical requirements for different medical personnel. This system was demonstrated to promote the mobility and flexibility for both the patients and the medical personnel, which further improves the quality of health care.

  7. Emerging technologies for knowledge resource management

    CERN Document Server

    Pandian, M

    2007-01-01

    Emerging Technologies for Knowledge Resource Management examines various factors that contribute to an enabled environment for optimum utilisation of information resources. These include the digital form of information resources, which are inherently sharable, consortia as a concept to bring people and materials together and unified portals as technology to bring together disparate and heterogeneous resources for sharing and access. The book provides a step-by-step guideline for system analysis and requirements analysis. The book also provides reviews of existing portal models for sharing reso

  8. Enviroportal.sk - information portal about the environment

    International Nuclear Information System (INIS)

    Navratil, R.; Kmet, M.

    2005-01-01

    In this presentation author deals with history, conception and exploitation of information portal about environment in the Slovak Republic. This portal - Enviroportal.sk was introduced into service in testing operation in April 2005. Perspectives of Enviroportal.sk are discussed

  9. Advances in the management of childhood portal hypertension.

    Science.gov (United States)

    McKiernan, Patrick; Abdel-Hady, Mona

    2015-05-01

    Portal hypertension is one of the most serious complications of childhood liver disease, and variceal bleeding is the most feared complication. Most portal hypertension results from cirrhosis but extra hepatic portal vein obstruction is the single commonest cause. Upper gastrointestinal endoscopy endoscopy remains necessary to diagnose gastro-esophageal varices. Families of children with portal hypertension should be provided with written instructions in case of gastrointestinal bleeding. Children with large varices should be considered for primary prophylaxis on a case-by-case basis. The preferred method is variceal band ligation. Children with acute bleeding should be admitted to hospital and treated with antibiotics and pharmacotherapy before urgent therapeutic endoscopy. All children who have bled should then receive secondary prophylaxis. The preferred method is variceal band ligation and as yet there is little evidence to support the use of β-blockers. Children with extrahepatic portal vein obstruction should be assessed for suitability of mesoportal bypass.

  10. Information Portals: A New Tool for Teaching Information Literacy Skills

    OpenAIRE

    Kolah, Debra; Fosmire, Michael

    2010-01-01

    Librarians at Rice and Purdue Universities created novel assignments to teach students important information literacy skills. The assignments required the students to use a third-party web site, PageFlakes and NetVibes, respectively, to create a dynamically updated portal to information they needed for their research and class projects. The use of off-the-shelf web 2.0 technology to enable students to discover the latest information in their subject areas of interest provides an engaging, han...

  11. Ethanol-induced increase in portal blood glow: Role of adenosine

    International Nuclear Information System (INIS)

    Orrego, H.; Carmichael, F.J.; Saldivia, V.; Giles, H.G.; Sandrin, S.; Israel, Y.

    1988-01-01

    The mechanism by which ethanol induces an increase in portal vein blood flow was studied in rats using radiolabeled microspheres. Ethanol by gavage resulted in an increase of 50-70% in portal vein blood flow. The ethanol-induced increase in portal blood flow was suppressed by the adenosine receptor blocker 8-phenyltheophylline. By itself, 8-phenyltheophylline was without effect on cardiac output or portal blood flow. Adenosine infusion resulted in a dose-dependent increase in portal blood flow. This adenosine-induced increase in portal blood flow was inhibited by 8-phenyltheophylline in a dose-dependent manner. Both alcohol and adenosine significantly reduced preportal vascular resistance by 40% and 60%, respectively. These effects were fully suppressed by 8-phenyltheophylline. It is concluded that adenosine is a likely candidate to mediate the ethanol-induced increase in portal vein blood flow. It is suggested that an increase in circulating acetate and liver hypoxia may mediate the effects of alcohol by increasing tissue and interstitial adenosine levels

  12. The Higgs portal above threshold

    Energy Technology Data Exchange (ETDEWEB)

    Craig, Nathaniel [Department of Physics, University of California,Santa Barbara, CA 93106 (United States); Lou, Hou Keong [Department of Physics, Princeton University,Princeton, NJ 08540 (United States); McCullough, Matthew [Theory Division, CERN,1211 Geneva 23 (Switzerland); Thalapillil, Arun [Department of Physics and Astronomy, Rutgers University,Piscataway, NJ 08854 (United States)

    2016-02-18

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  13. The Higgs portal above threshold

    International Nuclear Information System (INIS)

    Craig, Nathaniel; Lou, Hou Keong; McCullough, Matthew; Thalapillil, Arun

    2016-01-01

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  14. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin Fangfang; Gao Qinghuai; Xie Huchen; Nelson, Diana F.; Yu Yan; Kwok, W. Edmund; Totterman, Saara; Schell, Michael C.; Rubin, Philip

    1998-01-01

    Purpose: To investigate a method for the generation of digitally reconstructed radiographs directly from MR images (DRR-MRI) to guide a computerized portal verification procedure. Methods and Materials: Several major steps were developed to perform an MR image-guided portal verification procedure. Initially, a wavelet-based multiresolution adaptive thresholding method was used to segment the skin slice-by-slice in MR brain axial images. Some selected anatomical structures, such as target volume and critical organs, were then manually identified and were reassigned to relatively higher intensities. Interslice information was interpolated with a directional method to achieve comparable display resolution in three dimensions. Next, a ray-tracing method was used to generate a DRR-MRI image at the planned treatment position, and the ray tracing was simply performed on summation of voxels along the ray. The skin and its relative positions were also projected to the DRR-MRI and were used to guide the search of similar features in the portal image. A Canny edge detector was used to enhance the brain contour in both portal and simulation images. The skin in the brain portal image was then extracted using a knowledge-based searching technique. Finally, a Chamfer matching technique was used to correlate features between DRR-MRI and portal image. Results: The MR image-guided portal verification method was evaluated using a brain phantom case and a clinical patient case. Both DRR-CT and DRR-MRI were generated using CT and MR phantom images with the same beam orientation and then compared. The matching result indicated that the maximum deviation of internal structures was less than 1 mm. The segmented results for brain MR slice images indicated that a wavelet-based image segmentation technique provided a reasonable estimation for the brain skin. For the clinical patient case with a given portal field, the MR image-guided verification method provided an excellent match between

  15. Effects on growth after hypertension portal induced in young rats Efeitos da hipertensão portal sobre o crescimento de ratos jovens

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Correia Miranda

    2004-03-01

    Full Text Available BACKGROUND: Physical growth retardation in children with hypertension portal was observed regardless of schistosomiasis. It has been suggested that the shunt of portal blood through portosystemic collateral vessels would result in metabolic consequences that would lead to the physical growth deficit observed. AIM: Study the effects of hypertension portal in the growth of young rats. METHODS: The growth of 20 young rats, divided in the groups hypertension portal, n = 10, 103 3.7 g and sham operation n = 10, 102.6 ± 3.4 g was evaluated throughout 5 weeks and the following parameters were under observation: quality of diet offered, diet ingestion, weight increase and urinary creatinine within 24 hours. At the end of the experiment, blood was taken for biochemical tests, prothrombin time and hematocrit and hypertension portal was measured. RESULTS/CONCLUSIONS: Rats with hypertension portal induced at early stages of their lives present growth delay in the first week after surgery recovering their growth rhythm in the next weeks, catching up with the sham animals. Differences related to urinary creatinine excretion, biochemical tests and hematocrit were not observed. Such results are evidence against the hypothesis that the hypertension portal induced in early stages of rats lives would cause delay in their growth.RACIONAL: Atraso no crescimento foi observado em crianças com hipertensão portal independentemente da presença de esquistossomose. Sugeriu-se que o desvio de sangue pelas colaterais portossistêmicas justificaria os achados clínicos encontrados. OBJETIVO: Estudar os efeitos da hipertensão portal no crescimento de ratos jovens. MÉTODOS: O crescimento de 20 ratos divididos nos grupos hipertensão portal n = 10, 103 ± 3,7 g e grupo-controle, n = 10, 102,6 ± 3,4 g foi avaliado durante 5 semanas. Foram considerados a qualidade da dieta oferecida, a ingestão da dieta, o ritmo de crescimento ganho de peso, a excreção de creatinina urin

  16. Color Doppler evaluation of left gastric vein hemodynamics in cirrhosis with portal hypertension and its correlation with esophageal varices and variceal bleed

    International Nuclear Information System (INIS)

    Adithan, Subathra; Venkatesan, Bhuvaneswari; Sundarajan, Elangovan; Kate, Vikram; Kalayarasan, Raja

    2010-01-01

    The purpose of this study was to assess the value of Doppler evaluation of left gastric vein hemodynamics when monitoring portal hypertension patients, by correlating Doppler ultrasonography (USG) parameters with the severity of esophageal varices and occurrence of variceal bleeding. This study was carried out on 100 patients using Doppler USG and endoscopy. Forty-seven of these were patients with cirrhosis with portal hypertension, who had not had a recent variceal bleed (group 1) and 26 were patients with cirrhosis with portal hypertension, with a recent history of bleeding (group 2). The control group comprised of 27 subjects who did not have liver disease or varices on endoscopy (group 3). The hemodynamic parameters, namely the diameter of the left gastric vein and the direction and flow velocity in the vessel, were compared in these groups, with the grade of esophageal varices. Hepatofugal flow velocity in the left gastric vein was higher in patients with large-sized varices compared to those patients with small-sized varices (P < 0.001). The left gastric vein hepatofugal flow velocity was higher in patients with a recent variceal bleed than in those patients without a history of a recent variceal bleed (P < 0.0149). Large-sized varices were more commonly found in patients with a history of a recent variceal bleed (P < 0.0124). Left gastric vein hemodynamics were found to correlate with the severity of the varices and the occurrence of recent variceal bleed in patients with cirrhosis with portal hypertension. Evaluation of the left gastric vein portal dynamics could be helpful in monitoring the progress of the disease in these patients

  17. APPLICATIONS OF CURRENT TECHNOLOGY FOR CONTINUOUS MONITORING OF SPENT FUEL

    Energy Technology Data Exchange (ETDEWEB)

    Drayer, R.

    2013-06-09

    Advancements in technology have opened many opportunities to improve upon the current infrastructure surrounding the nuclear fuel cycle. Embedded devices, very small sensors, and wireless technology can be applied to Security, Safety, and Nonproliferation of Spent Nuclear Fuel. Security, separate of current video monitoring systems, can be improved by integrating current wireless technology with a variety of sensors including motion detection, altimeter, accelerometer, and a tagging system. By continually monitoring these sensors, thresholds can be set to sense deviations from nominal values. Then alarms or notifications can be activated as needed. Safety can be improved in several ways. First, human exposure to ionizing radiation can be reduced by using a wireless sensor package on each spent fuel cask to monitor radiation, temperature, humidity, etc. Since the sensor data is monitored remotely operator stay-time is decreased and distance from the spent fuel increased, so the overall radiation exposure is reduced as compared to visual inspections. The second improvement is the ability to monitor continuously rather than periodically. If changes occur to the material, alarm thresholds could be set and notifications made to provide advanced notice of negative data trends. These sensor packages could also record data to be used for scientific evaluation and studies to improve transportation and storage safety. Nonproliferation can be improved for spent fuel transportation and storage by designing an integrated tag that uses current infrastructure for reporting and in an event; tracking can be accomplished using the Iridium satellite system. This technology is similar to GPS but with higher signal strength and penetration power, but lower accuracy. A sensor package can integrate all or some of the above depending on the transportation and storage requirements and regulations. A sensor package can be developed using off the shelf technology and applying it to each

  18. Applications of current technology for continuous monitoring of spent fuel

    International Nuclear Information System (INIS)

    Drayer, R.

    2013-01-01

    Advancements in technology have opened many opportunities to improve upon the current infrastructure surrounding the nuclear fuel cycle. Embedded devices, very small sensors, and wireless technology can be applied to Security, Safety, and Nonproliferation of Spent Nuclear Fuel. Security, separate of current video monitoring systems, can be improved by integrating current wireless technology with a variety of sensors including motion detection, altimeter, accelerometer, and a tagging system. By continually monitoring these sensors, thresholds can be set to sense deviations from nominal values. Then alarms or notifications can be activated as needed. Safety can be improved in several ways. First, human exposure to ionizing radiation can be reduced by using a wireless sensor package on each spent fuel cask to monitor radiation, temperature, humidity, etc. Since the sensor data is monitored remotely operator stay-time is decreased and distance from the spent fuel increased, so the overall radiation exposure is reduced as compared to visual inspections. The second improvement is the ability to monitor continuously rather than periodically. If changes occur to the material, alarm thresholds could be set and notifications made to provide advanced notice of negative data trends. These sensor packages could also record data to be used for scientific evaluation and studies to improve transportation and storage safety. Nonproliferation can be improved for spent fuel transportation and storage by designing an integrated tag that uses current infrastructure for reporting and in an event; tracking can be accomplished using the Iridium satellite system. This technology is similar to GPS but with higher signal strength and penetration power, but lower accuracy. A sensor package can integrate all or some of the above depending on the transportation and storage requirements and regulations. A sensor package can be developed using off the shelf technology and applying it to each

  19. Condition Monitoring Through Advanced Sensor and Computational Technology

    International Nuclear Information System (INIS)

    Kim, Jung Taek; Park, Won Man; Kim, Jung Soo; Seong, Soeng Hwan; Hur, Sub; Cho, Jae Hwan; Jung, Hyung Gue

    2005-05-01

    The overall goal of this joint research project was to develop and demonstrate advanced sensors and computational technology for continuous monitoring of the condition of components, structures, and systems in advanced and next-generation nuclear power plants (NPPs). This project included investigating and adapting several advanced sensor technologies from Korean and US national laboratory research communities, some of which were developed and applied in non-nuclear industries. The project team investigated and developed sophisticated signal processing, noise reduction, and pattern recognition techniques and algorithms. The researchers installed sensors and conducted condition monitoring tests on two test loops, a check valve (an active component) and a piping elbow (a passive component), to demonstrate the feasibility of using advanced sensors and computational technology to achieve the project goal. Acoustic emission (AE) devices, optical fiber sensors, accelerometers, and ultrasonic transducers (UTs) were used to detect mechanical vibratory response of check valve and piping elbow in normal and degraded configurations. Chemical sensors were also installed to monitor the water chemistry in the piping elbow test loop. Analysis results of processed sensor data indicate that it is feasible to differentiate between the normal and degraded (with selected degradation mechanisms) configurations of these two components from the acquired sensor signals, but it is questionable that these methods can reliably identify the level and type of degradation. Additional research and development efforts are needed to refine the differentiation techniques and to reduce the level of uncertainties

  20. [Treatment of nontumoral portal vein thrombosis in cirrhosis].

    Science.gov (United States)

    Bañares, Rafael; Catalina, María-Vega

    2014-07-01

    Portal vein thrombosis in cirrhosis is a relatively common complication associated with the presence of an accompanying prothrombotic phenotype of advanced cirrhosis. The consequences of portal vein thrombosis are relevant because it can be associated with impaired hepatic function, might contraindicate hepatic transplantation and could increase morbidity in the surgical procedure. There is controversy concerning the most effective treatment of portal vein thrombosis, which is based on information that is seldom robust and whose primary objective is to achieve a return to vessel patency. Various studies have suggested that starting anticoagulation therapy early is associated with portal vein repatency more frequently than without treatment and has a low rate of complications. There are no proven data on the type of anticoagulant (low-molecular-weight heparins or dicoumarin agents) and the treatment duration. The implementation of TIPS is technically feasible in thrombosis without cavernous transformation and is associated with portal vein recanalization in a significant proportion of cases. Thrombolytic therapy does not appear to present an adequate balance between efficacy and safety; its use is therefore not supported for this indication. The proper definition of treatment for portal vein thrombosis requires properly designed studies to delimit the efficacy and safety of the various alternatives. Copyright © 2014 Elsevier España, S.L. All rights reserved.