WorldWideScience

Sample records for portal monitor applications

  1. Large vehicle portal monitor for perimeter safeguards applications

    International Nuclear Information System (INIS)

    Caldwell, J.T.; Atwater, H.F.; Bernard, W.; Bieri, J.M.; Shunk, E.R.

    1979-01-01

    We have developed a class of vehicle portal monitors based on shielded 4π geometry neutron counting. we have derived and experimentally verified an analytical expression relating the detection sensitivity of the neutron tunnel vehicle portal monitor to four design parameters of the system. For a given number of neutron detectors, this design achieves one or more orders of magnitude improvement in nuclear materials detection sensitivity over previous vehicle portal monitors

  2. Radioactivity Portal Monitor: An actual application and its unconventional detector

    International Nuclear Information System (INIS)

    Izraelevitch, F.; Matatagui, E.; Regueiro Veiga, J.L.

    2012-01-01

    A Radioactivity Portal Monitor is an instrument designed to be used at traffic check points to detect the presence of ionizing radiation in goods, vehicles, people, in critical places such as those at border road crossing, airports and seaports, the entrance at nuclear facilities etc. and alert the officer to the presence of radioactive and nuclear material. We have developed and built, and is in operation a Radioactivity Portal Monitor for gamma radiation. The detector and the associated electronics does not follow a conventional design concept and is based on a pressurized ionization chamber with a very large sensitive volume (60 liters) and a very large length (2 meters), and a very low level DC electronics (fAmp). The System is simple, and its operational characteristics are excellent. The reference radiation level is the background radiation, which is continuously measured, and compared with the radiation level measured when a subject (vehicle, person, good) goes trough the Monitor. The system automatically takes a decision, and alert the officer with an alarm signal if the detected radiation level is larger than the reference (dynamical) level. We will describe the designed system and some of its characterization results will be shown (author)

  3. An inverse source location algorithm for radiation portal monitor applications

    International Nuclear Information System (INIS)

    Miller, Karen A.; Charlton, William S.

    2010-01-01

    Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

  4. Computer Modeling of Radiation Portal Monitors for Homeland Security Applications

    International Nuclear Information System (INIS)

    Pagh, Richard T.; Kouzes, Richard T.; McConn, Ronald J.; Robinson, Sean M.; Schweppe, John E.; Siciliano, Edward R.

    2005-01-01

    Radiation Portal Monitors (RPMs) are currently being used at our nation's borders to detect potential nuclear threats. At the Pacific Northwest National Laboratory (PNNL), realistic computer models of RPMs are being developed to simulate the screening of vehicles and cargo. Detailed models of the detection equipment, vehicles, cargo containers, cargos, and radioactive sources are being used to determine the optimal configuration of detectors. These models can also be used to support work to optimize alarming algorithms so that they maximize sensitivity for items of interest while minimizing nuisance alarms triggered by legitimate radioactive material in the commerce stream. Proposed next-generation equipment is also being modeled to quantify performance and capability improvements to detect potential nuclear threats. A discussion of the methodology used to perform computer modeling for RPMs will be provided. In addition, the efforts to validate models used to perform these scenario analyses will be described. Finally, areas where improved modeling capability is needed will be discussed as a guide to future development efforts

  5. New ICPP portal monitor

    International Nuclear Information System (INIS)

    Georgeson, M.A.; Nichols, C.E.

    1981-04-01

    A large area gas filled proportional-detector portal monitor mounted in a swinging door frame has been designed and developed at the Idaho Chemical Processing Plant (ICPP). This monitor extends the sensitivity and speed of personnel contamination detection to levels equal to or exceeding that obtained using hand-held portable survey techniques. The new monitor has state-of-the-art electronics which result in rapid response, and use statistical principles in the alarm logic to reduce or eliminate spurious alarms. In addition, the evaluation of this instrument indicates that it will detect small enough quantities of U-235 in shielded containers to meet current special nuclear materials (SNM) detection standards. Simultaneous detection of very low level contamination and small quantities of SNM results in a monitor particularly useful for nuclear installations

  6. Roadside Tracker Portal-less Portal Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Ziock, Klaus-Peter [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cheriyadat, Anil M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bradley, Eric Craig [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cunningham, Mark F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fabris, Lorenzo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goddard, Jr, James Samuel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hornback, Donald Eric [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Karnowski, Thomas Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kerekes, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Newby, Jason [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-07-01

    This report documents the full development cycle of the Roadside Tracker (RST) Portal-less Portal monitor (Fig. 1) funded by DHS DNDO. The project started with development of a proof-of-feasibility proto-type, proceeded through design and construction of a proof-of-concept (POC) prototype, a test-and-evaluation phase, participation in a Limited Use Exercise that included the Standoff Radiation Detections Systems developed under an Advanced Technology Demonstration and concluded with participation in a Characterization Study conducted by DNDO.

  7. Portal monitoring technology control process

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    Portal monitors are an important part of the material protection, control, and accounting (MPC and A) programs in Russia and the US. Although portal monitors are only a part of an integrated MPC and A system, they are an effective means of controlling the unauthorized movement of special nuclear material (SNM). Russian technical experts have gained experience in the use of SNM portal monitors from US experts ad this has allowed them to use the monitors more effectively. Several Russian institutes and companies are designing and manufacturing SNM portal monitors in Russia. Interactions between Russian and US experts have resulted in improvements to the instruments. SNM portal monitor technology has been effectively transferred from the US to Russia and should be a permanent part of the Russian MPC and A Program. Progress in the implementation of the monitors and improvements to how they are used are discussed

  8. Application of a new containment and surveillance portal monitor data analysis method

    International Nuclear Information System (INIS)

    Pratt, J.C.; Henry, C.N.; Hastings, R.D.

    1980-01-01

    A new method for processing the information available from an ordinary doorway monitor in an earlier report is described. Additional tests of this concept on doorway monitors at facilities of the Los Alamos Scientific Laboratory have been made. The lessons learned and estimates of the sensitivity of this method for detection of a trickle of special nuclear material through the portal are presented

  9. Study of radiation portal monitor and its application to metal recycling industry

    International Nuclear Information System (INIS)

    Pujol, L.; Lara-Calleja, S.; Suarez-Navarro, M. J.; Gonzalez-Gonzalez, J. A.

    2009-01-01

    The industry of the iron and the steel in one of the most important sectors in Spain for its economic development. the recycling of metallic materials as well as the import of metallic scrap is very significant. Several reports on accidental dispersion or smelting of radioactive sources in metal recycling industries confirm the possibility that radioactive material might be mixed with scrap. In consequence, this type of accident shows the necessity of a rigorous and specific radiation control of the sector. The control of these materials with radioactive content can be carried out with radiation portal monitors installed at the entrance of these industries. The detection of radioactive materials presents special features as the continuous background acquisition or the minimisation of the relatively large number of innocent/nuisance detections. In the present work, we study a radiation portal monitor, the FHT-1388-T Thermo-Eberline. This is one of the usual radiation portal systems installed at the entrance of the metal recycling industry. Se study the characteristics and parameters of this portal monitor to optimise its use. furthermore, we propose some rapid tests for radiation portal systems in metal recycling industry. (Author) 16 refs

  10. Comparison of PVT and NaI(Tl) scintillators for vehicle portal monitor applications

    International Nuclear Information System (INIS)

    Siciliano, E.R.; Ely, J.H.; Kouzes, R.T.; Milbrath, B.D.; Schweppe, J.E.; Stromswold, D.C.

    2005-01-01

    The demand for radiation portal monitor (RPM) systems has increased, and their capabilities are being further scrutinized as they are being applied to the task of detecting nuclear weapons, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, where RPMs have been historically employed. In this new homeland security application, RPM systems must rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce. In light of this new Department of Homeland Security application, the capabilities of two popular gamma-ray-detector materials as applied to these needs are re-examined. Both experimental data and computer simulations, together with practical deployment experience, are used to assess currently available polyvinyltoluene and NaI(Tl) gamma-ray detectors for border applications

  11. Portal monitor incorporating smart probes

    International Nuclear Information System (INIS)

    Bartos, D.; Constantin, F.; Guta, T.

    2003-01-01

    Portal monitors are intended for detection of radioactive and special nuclear materials in vehicles, pedestrians, luggage, as well as for prevention of illegal traffic of radioactive sources. Monitors provide audio and visual alarms when radioactive and/or special nuclear materials are detected. They can be recommended to officers of customs, border guard and emergency services, civil defense, fire brigades, police and military departments or nuclear research or energetic facilities. The portal monitor developed by us consists in a portal frame, which sustains five intelligent probes having long plastic scintillator (0.5 liters each). The probes communicate, by serial transmission, with a Central Unit constructed on the basis of the 80552 microcontroller. This one manages the handshake, calculates the background, establishes the measuring time, starts and stops each measurement and makes all the other decisions. Sound signals and an infrared sensor monitor the passing through the portal and the measuring procedure. For each measurement the result is displayed on a LCD device contaminated/uncontaminated; for the contaminated case a loud and long sound signal is also issued. An RS 232 serial interface is provided in order to further developments or custom made devices. As a result, the portal monitor detects 1 μ Ci 137 Cs, spread all over a human body, in a 20 μR/h gamma background for a measuring time of 1.5 or 10 seconds giving a 99% confidence factor. (authors)

  12. A neutron portal monitor for vehicles

    International Nuclear Information System (INIS)

    Coop, K.L.; Fehlau, P.E.; Atwater, H.F.

    1987-01-01

    We have designed and built a portal vehicle monitoring systems for detecting neutron-emitting special nuclear material (SNM) such as plutonium. Monte Carlo calculations were used to optimize the design of the 15-cm-deep x 122-cm-high x 244-cm-long detector chambers, which utilize 3 He proportional counters inside a hollow polyethylene box. Results for a variety of parametric studies, including polyethylene thickness and detector number, are described. Our experimental measurements are in good agreement with the computer calculations. The monitor's decision logic uses the Sequential Probability Ratio Test (SPRT) on Poisson distributed counting data, which is superior to other statistical tests in many applications. We performed computer simulations of the SPRT logic to determine expected false-positive decision rates. A controller unit of our design that uses this SPRT was built commercially. The cost of the complete monitoring system is similar to that of vehicle portal monitors that detect gamma rays. This new neutron monitor can serve as an addition to standard gamma-ray vehicle portals or as a stand-alone portal monitor in particular safeguards monitoring situations. The monitor is being tested at Los Alamos and is scheduled for in-plant evaluation of another DOE facility in 1987. 7 refs

  13. Uzbekistan Radiation Portal Monitoring System

    International Nuclear Information System (INIS)

    Richardson, J; Knapp, R; Loshak, A; Yuldashev, B; Petrenko, V

    2005-01-01

    The work proposed in this presentation builds on the foundation set by the DTRA funded demonstration project begun in 2000 and completed in December of 2003. This previous work consisted of two phases whose overall objective was to install portal radiation monitors at four select ports-of-entry in Uzbekistan (Tashkent International Airport, Gisht-Kuprik (Kazakhstan border), Alat (Turkmenistan border), and Termez (Afghanistan border)) in order to demonstrate their effectiveness in preventing the illicit trafficking of nuclear materials. The objectives also included developing and demonstrating capabilities in the design, installation, operation, training, and maintenance of a radiation portal monitoring system. The system and demonstration project has proved successful in many ways. An effective working relationship among the Uzbekistan Customs Services, Uzbekistan Border Guards, and Uzbekistan Institute of Nuclear Physics has been developed. There has been unprecedented openness with the sharing of portal monitor data with Lawrence Livermore National Laboratory. The system has proved to be effective, with detection of illicit trafficking, and, at Alat, an arrest of three persons illegally transporting radioactive materials into Turkmenistan. The demonstration project has made Uzbekistan a model nonproliferation state in Central Asia and, with an expanded program, places them in a position to seal a likely transit route for illicit nuclear materials. These results will be described. In addition, this work is currently being expanded to include additional ports-of-entry in Uzbekistan. The process for deciding on which additional ports-of-entry to equip will also be described

  14. Application of a pedestrian portal monitor at Madrid International Airport in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Pujol, Ll., E-mail: luis.pujol@cedex.e [Centro de Estudios y Experimentacion de Obras Publicas (CEDEX), Alfonso XII, 3, 28014 Madrid (Spain); Univ Politecn Madrid (UPM), Dept Civil Engn Hydraul and Energet, ETSI Caminos, Profesor Aranguren, s/n, 28040 Madrid (Spain); Gonzalez-Gonzalez, J.A.; Suarez-Navarro, M.J. [Univ Politecn Madrid (UPM), Dept Civil Engn Hydraul and Energet, ETSI Caminos, Profesor Aranguren, s/n, 28040 Madrid (Spain)

    2011-04-15

    Three pedestrian portal monitor systems, designed to detect illicit trafficking or inadvertent movement of radioactive materials carried by passengers at airports, have been evaluated. The systems were supplied by three manufacturers: Bicron, Exploranium and Thermo-Eberline. In an initial evaluation, conducted at the Laboratory of Nuclear Engineering of the School of Civil Engineering, it was observed that the FHT-1372 system manufactured by Thermo-Eberline gave a more sensitive response and allowed the measurement of total photon dose rate and artificial photon dose rate. Therefore, this system was installed at Barajas International Airport in Madrid in 2002 for a period of 108 days in order to select an appropriate investigation level (defined as the radiation level that is selected as the trigger for further investigation). During this period 1,339,931 passengers were screened and a total of 39 alarms were triggered, 5 of which with a value 10 times the mean value of the natural background from photon radiation (which was 85 nSv/h), and no alarms exceeded 100 {mu}Sv/h at 1 m distance, which is the level of response for legal transport of radioactive materials set by the International Atomic Energy Agency (IAEA). An investigation level of approximately 1.3 times the natural background was finally selected. This value coincides with the results obtained in the ITRAP (Illicit Trafficking Radiation Detection Assessment Program) carried out by the IAEA.

  15. Portal monitor evaluation and test procedure

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Rich, B.L.

    1983-10-01

    The purpose was to develop techniques and procedures to allow users to measure performance and sensitivity of portal monitors. Additionally, a methodology was developed to assist users in optimizing monitor performance. The two monitors tested utilized thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: a) background count rate and the statistical variability, b) detector efficiency at different distances, c) moving source sensitivity for various size sources and speeds, and d) false alarm rates at different background levels. A model was developed for the moving source measurements to compare the experimental data with measured results, and to test whether it is possible to adequately model the behavior of a portal monitor's response to a moving source. The model results were compared with the actual test results. A procedure for testing portal monitors is also given. 1 reference, 9 figures, 8 tables

  16. Interactive monitoring portal for fusion simulations

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D.P.; Kim, E.N.; Flanagan, S.M.; Lee, X.

    2012-01-01

    Highlights: ► We designed a web-based monitoring system that tracks the status of fusion simulations. ► Our system is scalable to monitor the simulations running on distributed supercomputers and clusters located at multiple geographical locations. ► The monitoring portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. ► Our system utilizes the open source software, such as Python, Django, MySQL, Apache, and MDSplus. - Abstract: The Center for Simulation of RF Wave Interactions with Magnetohydrodynamics (SWIM) Project is a proto-Fusion Simulation Program (FSP) whose goal is to study high-performance fusion plasmas and perform comprehensive simulations that are essential to the development of fusion. SWIM team members are geographically distributed and utilize distributed supercomputers for computational simulations. Due to the highly distributed computational work environment, the SWIM team has the difficulty of monitoring code runs and discovering historical runs. To alleviate this difficulty a web-based monitoring portal has been developed and deployed. The monitoring portal tracks the progress of simulations and automatically collects metadata in real-time. This capability helps scientists to effectively utilize precious computer resources. Furthermore, the portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. The user interface provides rapid discovery capability via multi-field searching and sorting. The development of the monitoring portal used open source software, such as Python, Django, MySQL, and Apache. It uses MDSplus for data management, Memcached for data caches, and OpenID for single sign-on security. This paper describes the software architecture, related technologies and deployment experiences of the monitoring portal.

  17. ICPP digital wide area portal monitor

    International Nuclear Information System (INIS)

    Nichols, C.E.

    1978-01-01

    A portal montior is described which is used to check personnel for contamination. The monitor is extremely sensitive. In addition to personnel contamination control, it serves as an extremely effective SNM detector capable of detecting U-235 in half the quantities specified in Federal Standards

  18. R2 Water Quality Portal Monitoring Stations

    Science.gov (United States)

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  19. Portal monitoring for detecting fissile materials and chemical explosives

    International Nuclear Information System (INIS)

    Albright, D.

    1992-01-01

    The portal monitoring of pedestrians, packages, equipment, and vehicles entering or leaving areas of high physical security has been common for many years. Many nuclear facilities rely on portal monitoring to prevent the theft or diversion of plutonium and highly enriched uranium. At commercial airports, portals are used to prevent firearms and explosives from being smuggled onto airplanes. An August 1989 Federal Aviation Administration (FAA) regulation requires US airlines to screen luggage on international flights for chemical explosives. This paper reports that portal monitoring is now being introduced into arms-control agreements. Because some of the portal-monitoring equipment that would be useful in verifying arms-control agreements is already widely used as part of the physical security systems at nuclear facilities and commercial airports, the authors review these uses of portal monitoring, as well as its role in verifying the INF treaty. Then the authors survey the major types of portal-monitoring equipment that would be most useful in detecting nuclear warheads or fissile material

  20. Time Series Evaluation of Portal Monitor Data

    International Nuclear Information System (INIS)

    Robinson, Sean M.; Bender, Sarah E.; Lopresti, Charles A.; Woodring, Mitchell L.

    2008-01-01

    Radiation portal monitors screen cargo and personal vehicle traffic at international border crossings to detect and interdict illicit sources which may be present in the commerce stream. One difficulty faced by RPM systems is the prospect of false alarms, or undesired alarms due to background fluctuation, or Naturally-Occurring Radioactive Material (NORM) sources in the commerce stream. In general, NORM alarms represent a significant fraction of the nuisance alarms at international border crossings, particularly with Polyvinyl-Toluene (PVT) RPM detectors, which have only very weak spectral differentiation capability. With PVT detectors, the majority of detected photon events fall within the Compton continuum of the material, allowing for very little spectral information to be preserved (1). Previous work has shown that these detectors can be used for limited spectroscopy, utilizing around 8 spectral bins to further differentiate some NORM and other nuisance sources (2). NaI based systems achieve much more detailed spectral resolution from each measurement of a source, but still combine all measurements over a vehicle's occupancy in order to arrive at a spectrum to be analyzed

  1. R2 Water Quality Portal Monitoring Stations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on...

  2. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  3. Special Nuclear Material Portal Monitoring at the Nevada Test Site

    International Nuclear Information System (INIS)

    DeAnn Long; Michael Murphy

    2008-01-01

    Prior to April 2007, acceptance and performance testing of the various Special Nuclear Material (SNM) monitoring devices at the Nevada Test Site (NTS) was performed by the Radiological Health Instrumentation department. Calibration and performance testing on the PM-700 personnel portal monitor was performed, but there was no test program for the VM-250 vehicle portal monitor. The handheld SNM monitors, the TSA model 470B, were being calibrated annually, but there was no performance test program. In April of 2007, the Material Control and Accountability Manager volunteered to take over performance testing of all SNM portal monitors at NTS in order to strengthen the program and meet U.S. Department of Energy Order requirements. This paper will discuss the following activities associated with developing a performance testing program: changing the culture, learning the systems, developing and implementing procedures, troubleshooting and repair, validating the process, physical control of equipment, acquisition of new systems, and implementing the performance test program

  4. Increase in Efficiency of Use of Pedestrian Radiation Portal Monitors

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    Most international airports in the world use radiation portal monitors (RPM) for primary radiation control organization. During the exploitation pedestrian radiation portal monitors operators (in the Russian Federation it is a special subdivision of customs officials) have certain problems related to the search of an ionizing radiation source causing the alarm signal of a radiation monitor. Radiation portal monitors at standard (factory) settings have to find out the illegal moving of the radioisotopes moved by physical persons passing through a controlled zone and having a steady radiation by the gamma or neutron channel. The problem is that recently the number of the ownerships who underwent treatment or medical diagnostics with the use of radio pharmaceuticals considerably increased, i.e,. ownerships represent such an ionizing radiation source. The operator of the radiation portal monitor has to define very quickly whether the ownership is a violator (takes unsolved radioisotopes illegally) or is just a patient of the clinic who underwent treatment/diagnostics with the use of radio pharmaceuticals. The research showing the radioisotopes which are most often used in the medical purposes are given in article, it is offered to use the new software developed by the authors allowing the operator of the radiation portal monitor to define the location of the ownership which has such ionizing radiation source by the activity of radiation similar to the radiation from radio pharmaceuticals.

  5. New containment and surveillance portal monitor data analysis methed

    International Nuclear Information System (INIS)

    Henry, C.N.; Pratt, J.C.

    1979-01-01

    A new containment and surveillance portal monitor data analysis method has been developed. Current approaches use only the data from a single passage and an average background interval for alarm determination. The new method improves performance by summing the counts from many passages for comparison to the expected count, thus improving the statistical accuracy

  6. Testing of portal monitors for personnel contamination control

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Stalker, A.C.; Baker, K.R.; Littleton, M.L.; Rich, B.L.

    1983-04-01

    This is a report of an INPO-funded evaluation of state-of-the-art portal monitors used to detect personnel contamination. The project developed techniques and procedures to evaluate the performance and sensitivity of the portal monitors which provided data for intercomparison. An additional accomplishment was development of a methodology to assist manufacturers and users to optimize the monitor settings, and to provide technical basis for the eventual use of fixed monitors to replace frisking for contamination control. The monitors tested utilize thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: (1) background count rate and the statistical variability, (2) detector efficiency at different distances, (3) moving source sensitivity for various size sources and speeds, and (4) false alarm rates at different background levels. A model has been developed for the moving source measurements to compare the experimental data, and to test whether it is possible to adequately model the behavior of a portal monitor response to a moving source. The model results with the actual test results are compared

  7. Special Nuclear Material Portal Monitoring at the Nevada Test Site

    International Nuclear Information System (INIS)

    Mike Murphy

    2008-01-01

    In the past, acceptance and performance testing of the various Special Nuclear Material (SNM) monitoring devices at the Nevada Test Site has been performed by the Radiological Health Instrumentation Department. Calibration and performance tests on the PM-700 personnel portal monitor were performed but there was no test program for the VM-250 vehicle portal monitor because it had never been put into service. The handheld SNM monitors, the TSA model 470B, were being calibrated annually, but there was no program in place to test them quarterly. In April of 2007, the Material Control and Accountability (MC and A) Manager at the time decided that the program needed to be strengthened and MC and A took over performance testing of all SNM portal monitoring equipment. This paper will discuss the following activities associated with creating a performance testing program: changing the culture, learning the systems, writing procedures, troubleshooting/repairing, validating the process, control of equipment, acquisition of new systems, and running the program

  8. Applications of portals in the energetic sector; Aplicaciones de portales en el sector energetico

    Energy Technology Data Exchange (ETDEWEB)

    Santos Dominguez, Martin; Arroyo Figueroa, Gustavo [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2000-07-01

    An operative portal joins the applications, contents and services of the company in a single page of Intranet such way that promises to change deeply the information technology in the next years. The corporative portals will change what people visualize in the screen of their computer at the beginning of every working day. Unlike seeing the network (Web) only with pages of language of hypertext bearing (HTML), the corporative portal acts as a gate between Internet and the private networks. This article presents a general vision of the benefits of the corporative portals, the existing technologies and the potential markets. [Spanish] Un portal operativo une las aplicaciones, contenidos y servicios de la empresa en una sola pagina de Intranet, de tal forma que promete cambiar, profundamente la tecnologia de la informacion en los proximos anos. Los portales corporativos cambiaran lo que la gente visualiza en la pantalla de su computadora al comienzo de cada dia de trabajo. A diferencia de ver la red (Web) solo con paginas de lenguaje de marcacion de hipertexto (HTML), el portal corporativo actua como compuerta entre Internet y las redes privadas. Este articulo presenta una vision general de los beneficios de los portales corporativos, las tecnologias y los mercados potenciales existentes.

  9. A theoretical approach to calibrate radiation portal monitor (RPM) systems

    International Nuclear Information System (INIS)

    Nafee, Sherif S.; Abbas, Mahmoud I.

    2008-01-01

    Radiation portal monitor (RPM) systems are widely used at international border crossings, where they are applied to the task of detecting nuclear devices, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, the former being required to rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce [Chambers, W.H., Atwater, H.F., Fehlau, P.E., Hastings, R.D., Henry, C.N., Kunz, W.E., Sampson, T.E., Whittlesey, T.H., Worth, G.M., 1974. Portal Monitor for Diversion Safeguards. LA-5681, Los Alamos Scientific Laboratory, Los Alamos, NM]. In the present work, compact analytical formulae are derived and used to calibrate two RPM systems with isotropic radiating sources: (i) polyvinyltoluene (PVT) or plastic and (ii) thallium-doped crystalline sodium iodide, NaI(Tl), gamma-ray detector materials. The calculated efficiencies are compared to measured values reported in the literatures, showing very good agreement

  10. Application of the smart portal in transportation

    International Nuclear Information System (INIS)

    Kercel, S.W.; Baylor, V.M.; Dress, W.B.; Hickerson, T.W.; Jatko, W.B.; Labaj, L.E.; Muhs, J.D.; Pack, R.M.

    1996-01-01

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developed a ''Portal-of-the-Future'', or ''smart portal''. This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiogram, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals

  11. Application of the smart portal in transportation

    Energy Technology Data Exchange (ETDEWEB)

    Kercel, S.W.; Baylor, V.M.; Dress, W.B.; Hickerson, T.W.; Jatko, W.B.; Labaj, L.E.; Muhs, J.D.; Pack, R.M.

    1996-12-31

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developed a ``Portal-of-the-Future``, or ``smart portal``. This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiogram, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals.

  12. Application of the smart portal in transportation

    Science.gov (United States)

    Kercel, Stephen W.; Baylor, Vivian M.; Dress, William B.; Hickerson, Tim W.; Jatko, William B.; Labaj, Leo E.; Muhs, Jeffrey D.; Pack, Richard M.

    1997-02-01

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developing a `Portal-of-the-Future', or `smart portal.' This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiograms, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals.

  13. A strategic analysis of Business Objects' portal application

    OpenAIRE

    Kristinsson, Olafur Oskar

    2007-01-01

    Business Objects is the leading software firm producing business intelligence software. Business intelligence is a growing market. Small to medium businesses are increasingly looking at business intelligence. Business Objects' flagship product in the enterprise market is Business Objects XI and for medium-size companies it has Crystal Decisions. Portals are the front end for the two products. InfoView, Business Objects portal application, lacks a long-term strategy. This analysis evaluates...

  14. Enterprise Portals und Enterprise Application Integration - Begriffsbestimmung und Integrationskonzeptionen

    OpenAIRE

    Schelp, Joachim; Winter, Robert

    2002-01-01

    Unter den Stichworten »Enterprise Portals« und »Enterprise Application Integration« werden neue Herausforderungen an die Applikationsarchitektur der Unternehmungen gestellt. Bei beiden spielt die Integration vorhandener und das Einfügen neuer Applikationen eine große Rolle. Beiden Themen ist gemein, dass sie die Diskussion bestimmter technischer Konzepte aus den vergangenen Jahren fortsetzen: Portale stellen das moderne Frontend dar, über das die verschiedenen E-Business-Konzepte umgesetzt we...

  15. Standardisation of radiation portal monitor controls and readouts

    International Nuclear Information System (INIS)

    Tinker, Michael R.

    2010-01-01

    There is an urgent need to standardise the numbering configuration of radiation portal monitor sensing panels. Currently, manufacturers use conflicting numbering schemes that may confuse operators of these varied systems. There is a similar problem encountered with the varied choices of colored indicator lights and colored print lines designated for gamma and neutron alarms. In addition, second-party software that changes the alarm color scheme may also have been installed. Furthermore, no provision exists for the color blind or to provide work stations with only black ink on alarm printouts. These inconsistencies and confusing setups could inadvertently cause a misinterpretation of the alarm, resulting in the potential release of a radiological hazard into a sovereign country. These issues are discussed, and a proposed solution is offered.

  16. Integrated neutron/gamma-ray portal monitors for nuclear safeguards

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1994-01-01

    Radiation monitoring is one nuclear-safeguards measure used to protect against the theft of special nuclear materials (SNM) by pedestrians departing from SNM access areas. The integrated neutron/gamma-ray portal monitor is an ideal radiation monitor for the task when the SNM is plutonium. It achieves high sensitivity for detecting both bare and shielded plutonium by combining two types of radiation detector. One type is a neutron-chamber detector, comprising a large, hollow, neutron moderator that contains a single thermal-neutron proportional counter. The entrance wall of each chamber is thin to admit slow neutrons from plutonium contained in a moderating shield, while the other walls are thick to moderate fast neutrons from bare or lead-shielded plutonium so that they can be detected. The other type of detector is a plastic scintillator that is primarily for detecting gamma rays from small amounts of unshielded plutonium. The two types of detector are easily integrated by making scintillators part of the thick back wall of each neutron chamber or by inserting them into each chamber void. The authors compared the influence of the two methods of integration on detecting neutrons and gamma rays, and they examined the effectiveness of other design factors and the methods for signal detection as well

  17. On the usefulness of portal monitor unit subtraction in radiation therapy

    International Nuclear Information System (INIS)

    Kuperman, Vadim Y; Lubich, Leslie M

    2003-01-01

    In order to avoid additional dose to patients caused by portal imaging with megavoltage x-rays, portal monitor units (MUs) are frequently subtracted from the actual treatment MUs. This study examines the usefulness of portal MU subtraction in radiation therapy. For 11 prostate cancer patients treated with 23 MV photons, dose to prostate due to portal filming with 6 MV photons was determined. In all 11 patients subtraction of portal MU values from the actual treatment MUs resulted in a small underdosing of the prostate with an average treatment error of -0.5%. Portal filming without MU subtraction would cause small overdosing of the prostate with an average treatment error of 1.2%. The results of this study indicate that the benefits of portal MU subtraction are in doubt if (a) the energy of treatment x-rays is much higher than that of the portal x-rays and/or (b) when radiotherapy is performed with physical wedges. Based on the obtained results, we argue against unconditional use of the portal MU subtraction method to eliminate the dose from portal imaging

  18. Application of SharePoint Portal Technologies in Public Enterprises

    Directory of Open Access Journals (Sweden)

    Dragan Đokić

    2015-03-01

    Full Text Available Nowadays, systematic reforms are realized acrossmany countries. One of the characteristics of these reforms is necessity for rationalization of expenses in governmental and public enterprises. Rationalization of expenses can be achieved by more extensive application of information and communication technologies based on internet technologies and cloud computing. These systems include huge number of services, applications, resources, users and roles. At the same time, concepts of scalability, availability, ubiquity and pervasiveness need to be applied. This paper deals with application of portal technologies for enhanced content management, document management, and collaboration within public enterprises. The goal is to achieve efficient exchange of information on all hierarchical levels, as well as mechanisms of reporting and performance measurements, such as business intelligence and key performance indicators. The model is based on SharePoint portal technologies. A case study of application within the public enterprise Post of Serbia is described.

  19. Global Mercury Observatory System Land-based Monitoring Data Portal

    Data.gov (United States)

    U.S. Environmental Protection Agency — Global Mercury Observation System On-line Data Portal. This dataset is associated with the following publication: Carbone, F., A. Bruno, A. Naccarato, F. De Simone,...

  20. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Energy Technology Data Exchange (ETDEWEB)

    Paff, Marc Gerrit, E-mail: mpaff@umich.edu; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-21

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  1. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-01

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  2. Percutaneous transsplenic catheterization of portal vein: technique and clinical application

    International Nuclear Information System (INIS)

    Zhu Kangshun; Huang Mingsheng; Pang Pengfei; Zhou Bin; Xu Changmo; Qian Jiesheng; Li Zhengran; Jiang Zaibo; Shan Hong

    2010-01-01

    Objective: To evaluate the feasibility of percutaneous transsplenic portal vein catheterization (PTSPC). Methods: Thirty patients with portal hypertension underwent gastroesophageal variceal embolization via PTSPC route, 2 of which simultaneously underwent portal vein stenting. This study included the patients with portal venous obstruction (tumor embolus or thrombus) or the patients with serious liver atrophy caused by liver cirrhosis. The patients who had severe coagulation insufficiency (with prothrombin time > 20 s) were excluded. Of the 30 patients, 17 had primary hepatocellular carcinoma with main portal venous tumor embolus, 13 had cirrhosis with severe liver atrophy and (or)slight or moderate ascite. Before this study, all of 30 patients had a history of variceal bleeding, and 16 patients had a normal coagulation level, 10 patients had a mildly prolonged prothrombin time (14-17 s), 4 patients had a moderately prolonged prothrombin time (18-20 s). All of 30 patients underwent upper abdomen CT enhanced scanning before this procedure, and the site, direction, and depth of splenic vein branch puncture were decided by CT images. The technology of PTSPC, procedure-related complications, and its clinical application were retrospectively analyzed. Results: PTSPC was performed successfully in 28 of 30 patients. Two cases failed because of a small intrasplenic vein. Procedure-related complications occurred in 6 patients (20.0%), which had decrease of hemoglobin concentration (15-50 g/L). Four of them needed blood transfusion. In the six patients, one patient (3.3%) with abdominal cavity hemorrhage had a serious drop of blood pressure 2 hours after procedure, whose clinical symptoms were relieved after four units of packed RBC and a great quantity of fluid were transfused. Twenty-eight patients whose PTSPC were successfully performed underwent variceal embolization, 2 of them were placed with portal vein covered stents. During a median follow-up period of 6 months

  3. The role of SNM portal monitoring in the Russian MPC ampersand A program

    International Nuclear Information System (INIS)

    York, R.L.

    1997-01-01

    Controlling the movement of nuclear materials is still the most effective nonproliferation measure. Pedestrian and vehicle portal monitors have been an established tool for preventing the unauthorized movement of SNM across US nuclear facility boundaries for 15 years. Because the portals are reliable and easy to install, they are an efficient first step to improve the security at Russian nuclear facilities. The portals were first furnished to Russian facilities for testing and evaluation. After Russian technical experts gained experience with the operating parameters, the instruments were implemented at appropriate locations at each facility. This process has been executed at IPPE, VNIEF, VNIITF, RCC KI, and SKhK. The transfer of the portal monitoring technology to Russian institutes to promote the manufacture of Russian instruments is also an important goal of the program. The process was started with two portal monitor workshops attended by representatives of Russian facilities at ORNL and followed by technical collaborations at the individual Russian facilities. The success of this effort is illustrated by the recent workshop hosted by VNIIA at the SCI in Obninsk where specialists from thirty-two Russian nuclear facilities met to discuss their experience in portal monitoring. Twelve institutes and firms reported on the status of Russian designed and manufactured instruments. Details of this program will be presented in this paper

  4. Development of NORM determination Algorithm for Radiation Portal Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hwan; Kim, Ye Won; Yoo, Hyun Jun; Kim, Chan Kyu; Lee, Sang Heon; Cho, Gyu Seong [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, probability of distinguishing nuclide analysis is proposed by measuring compton energy spectrum of gamma ray with large-area PVT scintillator to solve fundamental problem. US coast guard (USCG) suggested the methods for which terrorism could be prevented to international maritime organization (IMO) and the bill in which container safety was assured was suggested by U.S customs officials. However, radiation portal monitors (RPMs) running at the airport and the harbor cannot distinguish special cargo material (SNM) from naturally occurring radioactive materials (NOMR) containing a small dose of radioisotope from nature. Consequently, cargo sorted out by RPM using polyvinyl-toluene (PVT) scintillator contains approximately 99% of NORM (such as cat litter, potash, tableware and etc.) Many research institutes are under way to reduce such a nuisance alarm. Tom Burr conducted pattern recognition methods with extracted 184 features (46 features from each of four panels) from 235 profiles out of 406 profiles representing gamma alarm. But this method is more like statistical analysis using the data of low and high gamma than practical nuclide analysis. So it has limitation to reduce nuisance alarm. Regarding to the experimental result for difference distances between the source and the scintillator using large-area PVT based plastic scintillator, the linearity was not secured when the distance is from 0cm to 20cm. It is expected that, for these cases, the scintillation areas in which photon is emitted were small. The distance between PMTs and these areas was too far to detect every emitted photon because the photons were attenuated by plastic scintillator. Because of this reason, energy spectra were shifted to relatively lower channel. While, no more spectrum shifting occurred for 50cm and 100cm. It is considered that the increase of the gamma source solid angle makes scintillation area larger and no more spectrum shifting occur. With this experiment, it was

  5. Development of NORM determination Algorithm for Radiation Portal Monitors

    International Nuclear Information System (INIS)

    Kim, Jin Hwan; Kim, Ye Won; Yoo, Hyun Jun; Kim, Chan Kyu; Lee, Sang Heon; Cho, Gyu Seong

    2016-01-01

    In this paper, probability of distinguishing nuclide analysis is proposed by measuring compton energy spectrum of gamma ray with large-area PVT scintillator to solve fundamental problem. US coast guard (USCG) suggested the methods for which terrorism could be prevented to international maritime organization (IMO) and the bill in which container safety was assured was suggested by U.S customs officials. However, radiation portal monitors (RPMs) running at the airport and the harbor cannot distinguish special cargo material (SNM) from naturally occurring radioactive materials (NOMR) containing a small dose of radioisotope from nature. Consequently, cargo sorted out by RPM using polyvinyl-toluene (PVT) scintillator contains approximately 99% of NORM (such as cat litter, potash, tableware and etc.) Many research institutes are under way to reduce such a nuisance alarm. Tom Burr conducted pattern recognition methods with extracted 184 features (46 features from each of four panels) from 235 profiles out of 406 profiles representing gamma alarm. But this method is more like statistical analysis using the data of low and high gamma than practical nuclide analysis. So it has limitation to reduce nuisance alarm. Regarding to the experimental result for difference distances between the source and the scintillator using large-area PVT based plastic scintillator, the linearity was not secured when the distance is from 0cm to 20cm. It is expected that, for these cases, the scintillation areas in which photon is emitted were small. The distance between PMTs and these areas was too far to detect every emitted photon because the photons were attenuated by plastic scintillator. Because of this reason, energy spectra were shifted to relatively lower channel. While, no more spectrum shifting occurred for 50cm and 100cm. It is considered that the increase of the gamma source solid angle makes scintillation area larger and no more spectrum shifting occur. With this experiment, it was

  6. The consideration and practice of data processing of WBS-II portal β monitor

    International Nuclear Information System (INIS)

    Du Xiangyang; Dong Qiangmin; Zhang Yong; Han Shuping; Wang Xiaodong; Fan Liya; Rao Xianming

    2001-01-01

    The main aspects of background and human body measurement data processing of WBS-II Portal β Monitor were discussed. The theory analysis of setting high and low background-warning threshold in data processing was done. The relative reference values were partly provided to the local executives. The measurement 'blind zone' and the whole warning function of data processing were discussed. And the structure, the process of monitoring and the microcomputer's hard wares of WBS-II Portal β Monitor were simply introduced

  7. Recent trends in print portals and Web2Print applications

    Science.gov (United States)

    Tuijn, Chris

    2009-01-01

    case, the ordering process is, of course, not fully automated. Standardized products, on the other hand, are easily identified and the cost charged to the print buyer can be retrieved from predefined price lists. Typically, higher volumes will result in more attractive prices. An additional advantage of this type of products is that they are often defined such that they can be produced in bulk using conventional printing techniques. If one wants to automate the ganging, a connection must be established between the on-line ordering and the production planning system. (For digital printing, there typically is no need to gang products since they can be produced more effectively separately.) Many of the on-line print solutions support additional features also available in general purpose e-commerce sites. We here think of the availability of virtual shopping baskets, the connectivity with payment gateways and the support of special facilities for interfacing with courier services (bar codes, connectivity to courier web sites for tracking shipments etc.). Supporting these features also assumes an intimate link with the print production system. Another development that goes beyond the on-line ordering of printed material and the submission of full pages and/or documents, is the interactive, on-line definition of the content itself. Typical applications in this respect are, e.g., the creation of business cards, leaflets, letter heads etc. On a more professional level, we also see that more and more publishing organizations start using on-line publishing platforms to organize their work. These professional platforms can also be connected directly to printing portals and thus enable extra automation. In this paper, we will discuss for each of the different applications presented above (traditional Print Portals, Web2Print applications and professional, on-line publishing platforms) how they interact with prepress and print production systems and how they contribute to the

  8. Technical aspects of portal technology application for e-health systems.

    Science.gov (United States)

    Kosińska, Joanna; Słowikowski, Paweł

    2004-01-01

    E-health is an emerging field on the intersection of medical information technologies, public health and business, referring to health services and information delivered or enhanced through the Internet and related technologies. Portal technology, allowing services to be accessible over the Internet is a perfect tool for providing e-health services. The use of portal technologies has had deep influence on the architecture of the whole e-health system, both regarding new subsystems and older ones which we want to integrate with the portal. Portals provide new possibilities for creating novel types of e-health applications as well. In this paper we provide a brief overview of e-health systems and portal technologies, and present many technical aspects of portal technology application for e-health systems such as the architecture of portal-based e-health systems, graphical user interfaces, access to various e-health systems' resources, personalization, security and privacy.

  9. Comparison of MCNP and Experimental Measurements for an HPGe-based Spectroscopy Portal Monitor

    International Nuclear Information System (INIS)

    Keyser, Ronald M.; Hensley, Walter K.; Twomey, Timothy R.; UPP, Daniel L.

    2008-01-01

    The necessity to monitor international commercial transportation for illicit nuclear materials resulted in the installation of many nuclear radiation detection systems in Portal Monitors. These were mainly gross counters which alarmed at any indication of high radioactivity in the shipment, the vehicle or even the driver. The innocent alarm rate, due to legal shipments of sources and NORM, or medical isotopes in patients, caused interruptions and delays in commerce while the legality of the shipment was verified. To overcome this difficulty, Department of Homeland Security (DHS) supported the writing of the ANSI N42.38 standard (Performance Criteria for Spectroscopy-Based Portal Monitors used for Homeland Security) to define the performance of a Portal Monitor with nuclide identification capabilities, called a Spectroscopy Portal Monitor. This standard defines detection levels and response characteristics for the system for energies from 25 keV to 3 MeV. To accomplish the necessary performance, several different HPGe detector configurations were modeled using MCNP for the horizontal field of view (FOV) and vertical linearity of response over the detection zone of 5 meters by 4.5 meters for 661 keV as representative of the expected nuclides of interest. The configuration with the best result was built and tested. The results for the FOV as a function of energy and the linearity show good agreement with the model and performance exceeding the requirements of N42.38

  10. Use of Portal Monitors for Detection of Technogenic Radioactive Sources in Scrap Metal

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    The article considers the features of organization of scrap-metal primary radiation control on the specialized enterprises engaging in its deep processing and storage at using by primary technical equipment - radiation portal monitors. The issue of this direction relevance, validity of radiation control implementation with the use of radiation portal monitors, physical and organizational bases of radiation control are considered in detail. The emphasis is put on the considerable increase in the number of technogenic radioactive sources detected in scrap-metal that results in the entering into exploitation of radioactive metallic structures as different building wares. One of reasons of such increase of the number of technogenic radioactive sources getting for processing with scrap-metal is the absence of any recommendations on the radiation portal monitors exploitation. The practical division of the article offers to recommendation on tuning of the modes of work of radiation portal monitors depending on influence the weather factor thus allowing to considerably increase the percent of technogenic radioactive sources detection.

  11. Design of microprocessor data acquisition system for pedestrian portal SNM monitor

    International Nuclear Information System (INIS)

    Zhang Wenliang

    2003-01-01

    The paper introduces the hardware structure and composition of data acquisition system for pedestrian portal special nuclear material (SNM) monitor. The hardware and software of single chip microprocessor AT89C52, LCM, keyboard and serial communication interface software are also discussed. (authors)

  12. The application of TIPSS in portal vein cancerous thrombosis complicated with portal hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Zhu Wenke; Liu Lang; Guo Tiansheng

    2002-01-01

    Objective: To discuss the technical skills and the contraindication of trans-jugular intrahepatic portosystemic shunt stent (TIPSS) in portal vein cancerous thrombosis (PVCT) complicated with portal hypertension. Methods: There were 16 cases of PVCT with portal hypertension, and average age of 53.6 yr. There were 9 cases with complete occlusion of portal vein trunk and 7 cases with incomplete thrombosis. There were 5 cases with cavernous transformation of the portal vein (CTPV). 1 case of simple upper gastro-intestinal tract (GIT) massive bleeding, 4 with refractory ascites and 11 with upper GIT massive bleeding and refractory ascites. Results: The procedure of TIPS was successful in 11 cases, the successful rate reached about 68.8%. The mean portal vein pressure was reduced from 4.9 kPa to 2.4 kPa with average 2. 5 kPa reduction. Ascites decreased, bleeding stopped and the clinical symptoms disappeared. The average survival period was 136 days. The procedure failed in 5 cases. Conclusions: TIPSS is an effective method to control the bleeding and ascites caused by PVCT. The PV cavernous transformation was the contraindication of TIPSS

  13. Development of integrated containment and surveillance system for fast critical facility FCA. Portal and penetration monitors

    International Nuclear Information System (INIS)

    Mukaiyama, Takehiko; Ogawa, Hironobu; Yokota, Yasuhiro.

    1998-01-01

    Manpower and radiation exposure problems, accompanied by frequent Non Destructive Assay (NDA) based inspections at the Fast Critical Facility FCA of Japan Atomic Energy Research Institute (JAERI), are a burden for both the inspectorates and the facility operator. In the hope of alleviating these burdens, the development of containment and surveillance measures for the FCA was initiated in 1979. The integrated containment and surveillance system consists of a portal monitor and a penetration monitor. The reactor building provides an ideal containment measure because of its explosion-proof, airtight structure and limited number of penetrations. The function of the portal monitor is to detect undeclared removal of nuclear material from the reactor building through the doorway. The penetration monitor is designed for surveillance of diversion routes through containment boundaries, and of safeguards related activities for bypassing the portal monitor. The combination of monitoring by the penetration monitor of containment boundaries and all their penetrations except for the doorway, and monitoring by the portal monitor, provides complete coverage of realistic diversion routes. The development of the system was completed in 1988 and the field trial test was conducted for the period of twelve running months. The final report on the field trial was concluded on January 1990. The major conclusion of the report was that the system is effective, reliable and efficient. Following this successful conclusion, the International Atomic Energy Agency (IAEA) accepted the system for meeting its safeguards goals at the FCA on condition that an independent IAEA authentication equipment is provided. The development of the authentication equipment is accomplished as an separate Japan Support Programme for Agency Safeguards (JASPAS) task. (author)

  14. Biowep: a workflow enactment portal for bioinformatics applications.

    Science.gov (United States)

    Romano, Paolo; Bartocci, Ezio; Bertolini, Guglielmo; De Paoli, Flavio; Marra, Domenico; Mauri, Giancarlo; Merelli, Emanuela; Milanesi, Luciano

    2007-03-08

    The huge amount of biological information, its distribution over the Internet and the heterogeneity of available software tools makes the adoption of new data integration and analysis network tools a necessity in bioinformatics. ICT standards and tools, like Web Services and Workflow Management Systems (WMS), can support the creation and deployment of such systems. Many Web Services are already available and some WMS have been proposed. They assume that researchers know which bioinformatics resources can be reached through a programmatic interface and that they are skilled in programming and building workflows. Therefore, they are not viable to the majority of unskilled researchers. A portal enabling these to take profit from new technologies is still missing. We designed biowep, a web based client application that allows for the selection and execution of a set of predefined workflows. The system is available on-line. Biowep architecture includes a Workflow Manager, a User Interface and a Workflow Executor. The task of the Workflow Manager is the creation and annotation of workflows. These can be created by using either the Taverna Workbench or BioWMS. Enactment of workflows is carried out by FreeFluo for Taverna workflows and by BioAgent/Hermes, a mobile agent-based middleware, for BioWMS ones. Main workflows' processing steps are annotated on the basis of their input and output, elaboration type and application domain by using a classification of bioinformatics data and tasks. The interface supports users authentication and profiling. Workflows can be selected on the basis of users' profiles and can be searched through their annotations. Results can be saved. We developed a web system that support the selection and execution of predefined workflows, thus simplifying access for all researchers. The implementation of Web Services allowing specialized software to interact with an exhaustive set of biomedical databases and analysis software and the creation of

  15. Biowep: a workflow enactment portal for bioinformatics applications

    Directory of Open Access Journals (Sweden)

    Romano Paolo

    2007-03-01

    Full Text Available Abstract Background The huge amount of biological information, its distribution over the Internet and the heterogeneity of available software tools makes the adoption of new data integration and analysis network tools a necessity in bioinformatics. ICT standards and tools, like Web Services and Workflow Management Systems (WMS, can support the creation and deployment of such systems. Many Web Services are already available and some WMS have been proposed. They assume that researchers know which bioinformatics resources can be reached through a programmatic interface and that they are skilled in programming and building workflows. Therefore, they are not viable to the majority of unskilled researchers. A portal enabling these to take profit from new technologies is still missing. Results We designed biowep, a web based client application that allows for the selection and execution of a set of predefined workflows. The system is available on-line. Biowep architecture includes a Workflow Manager, a User Interface and a Workflow Executor. The task of the Workflow Manager is the creation and annotation of workflows. These can be created by using either the Taverna Workbench or BioWMS. Enactment of workflows is carried out by FreeFluo for Taverna workflows and by BioAgent/Hermes, a mobile agent-based middleware, for BioWMS ones. Main workflows' processing steps are annotated on the basis of their input and output, elaboration type and application domain by using a classification of bioinformatics data and tasks. The interface supports users authentication and profiling. Workflows can be selected on the basis of users' profiles and can be searched through their annotations. Results can be saved. Conclusion We developed a web system that support the selection and execution of predefined workflows, thus simplifying access for all researchers. The implementation of Web Services allowing specialized software to interact with an exhaustive set of biomedical

  16. Development and application of efficient portal imaging solutions

    International Nuclear Information System (INIS)

    Boer, J.C.J. de

    2003-01-01

    This thesis describes the theoretical derivation and clinical application of methods to measure and improve patient setup in radiotherapy by means of electronic portal imaging devices (EPIDs). The focus is on methods that (1) are simple to implement and (2) add minimal workload. First, the relation between setup errors and treatment planning margins is quantified in a population-statistics approach. A major result is that systematic errors (recurring each treatment fraction) require about three times larger margins than random errors (fluctuating from fraction to fraction). Therefore, the emphasis is on reduction of systematic setup errors using off-line correction protocols. The new no action level (NAL) protocol, aimed at significant reduction of systematic errors using a small number of imaged fractions, is proposed and investigated in detail. It is demonstrated that the NAL protocol provides final distributions of residue systematic errors at least as good as the most widely applied comparable protocol, the shrinking action level (SAL) protocol, but uses only 3 imaged fractions per patient instead of the 8-10 required by SAL. The efficacy of NAL is demonstrated retrospectively on a database of measured setup errors involving 600 patients with weekly set-up measurements and prospectively in a group of 30 patients. The general properties of NAL are investigated using both analytical and Monte Carlo calculations. As an add-on to NAL, a correction verification (COVER) protocol has been developed using computer simulations combined with a risk analysis. With COVER, a single additional imaged fraction per patient is sufficient to reduce the detrimental effect of possible systematic mistakes in the execution of setup corrections to negligible levels. The high accuracy achieved with off-line setup corrections (yielding SDs of systematic errors ∼1 mm) is demonstrated in clinical studies involving 60 lung cancer patients and 31 head-and-neck patients. Furthermore

  17. Policy analysis and recommendations for the open source application development portal (OSADP).

    Science.gov (United States)

    2012-06-01

    This white paper addresses the policy and institutional issues that are associated with the development of an open source applications development portal (OSADP), part of a larger research effort being conducted under the ITS Programs Dynamic Mobi...

  18. Design of dual-road transportable portal monitoring system for visible light and gamma-ray imaging

    Science.gov (United States)

    Karnowski, Thomas P.; Cunningham, Mark F.; Goddard, James S.; Cheriyadat, Anil M.; Hornback, Donald E.; Fabris, Lorenzo; Kerekes, Ryan A.; Ziock, Klaus-Peter; Bradley, E. Craig; Chesser, J.; Marchant, W.

    2010-04-01

    The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third "alignment" camera for motion compensation and are mounted on a 50' deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

  19. Design of Dual-Road Transportable Portal Monitoring System for Visible Light and Gamma-Ray Imaging

    International Nuclear Information System (INIS)

    Karnowski, Thomas Paul; Cunningham, Mark F.; Goddard, James Samuel Jr.; Cheriyadat, Anil M.; Hornback, Donald Eric; Fabris, Lorenzo; Kerekes, Ryan A.; Ziock, Klaus-Peter; Bradley, Eric Craig; Chesser, Joel B.; Marchant, William

    2010-01-01

    The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third alignment camera for motion compensation and are mounted on a 50 deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

  20. GEO portal

    Data.gov (United States)

    US Agency for International Development — The USAID GeoPortal is a new application that groups web-based capabilities for on-demand discovery of and access to geospatial content, services, expertise, and...

  1. Strength analysis of support structure and characterization of prototype imaging portal monitor

    International Nuclear Information System (INIS)

    Khairul Handono; Alvano Yulian; Muhammad Awwaluddin

    2014-01-01

    The mechanical systems analysis and testing of control systems and data acquisition the prototype Portal Imaging Monitor Container has been conducted. Analysis of the mechanical system includes support holder important to maintain continuity of operations. While the analysis of the data acquisition system and electrically system done on the conveyor drive motor power supply. The purpose of the analysis and characterization for design improvements. The process of static analysis is done through a conveyor frame structure simulation in ANSYS 1.4 software. In the data acquisition system and the electrical system has been tested. From the results of the mechanical analysis showed that the design created has met the criteria of security and safety. While the data acquisition system testing the system can display the data through the Internet with either. (author)

  2. Scanning personnel for internal deposition of radioactive material with personnel contamination whole body friskers and portal monitors

    International Nuclear Information System (INIS)

    Lobdell, J.L.

    1996-01-01

    The potential for using personnel contamination devices such as whole body friskers and portal monitors for internal contamination monitoring was evaluated. Internally deposited radioactive material is typically determined with whole body counting systems. Whole body counts have traditionally been performed on personnel when they report for work, on a periodic basis (i.e., annually), when an uptake is suspected, and on termination. These counts incur significant expense. The monitored personnel pass through whole body friskers and portal monitors daily. This investigation was performed to determine if the external contamination monitors could provide an alternative to the more Costly whole body counting. The ability to detect 1% of a DAC for critical radioisotopes was applied as a detection criteria for this investigation. The results of whole body counts were used to identify the typical internal contamination radionuclides. From this list, the radioisotopes that would be the most difficult to measure were identified. From this review, 60 Co and 131 I were determined to be the critical radionuclides. One percent of a DAC for each isotope was placed, one at a time, in a humanoid phantom. The phantom was placed in the whole body frisker and open-quotes countedclose quotes. The phantom was carried through the portal monitor at a speed equivalent to a person walking through the monitor. Frequency of detection was derived for both systems. Practical aspects of integrating this screening system with traditional internal dosimetry programs are discussed

  3. Development of a New Analysis Tool for Evaluating and Correcting for Weather Conditions that Constrain Radiation Portal Monitor Performance

    International Nuclear Information System (INIS)

    Guzzardo, T.; Livesay, J.

    2011-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) developed the Adaptable, Multiplatform, Real-Time Analysis Package (AMRAP) for the continuous measurement of environmental radionuclide decay. AMRAP is a completely open source visualization and analysis package capable of combining a variety of data streams into an array of real-time plots. Once acquired, data streams are analyzed to store static images and extract data based on previously defined thresholds. AMRAP is currently used at ORNL to combine data streams from an Ortec Detective high-purity germanium (HPGe) detector, a TSA Systems radiation portal monitor (RPM), and an Orion weather station. The combined data are used to study the rain-induced increase in RPM background radiation levels. RPMs experience an increase in background radiation during precipitation due to the deposition of atmospheric radionuclides on the ground. Using AMRAP results in a real-time analysis workstation specifically dedicated to the study of RPM background radiation levels. By means of an editable library of common inputs, AMRAP is adaptable to remote monitoring applications that would benefit from the real-time visualization and analysis of radiation measurements. To study rain-induced increases in background radiation levels observed in radiation portal monitors (RPMs), researchers at Oak Ridge National Laboratory (ORNL) developed a software package that allows data with different formats to be analyzed and plotted in near real time. The Adaptable, Multiplatform, Real-Time Analysis Package (AMRAP) was developed to operate in the background and capture plots of important data based on previously defined thresholds. After executing AMRAP, segments of a data stream can be captured without additional post-processing. AMRAP can also display previously recorded data to facilitate a detailed offline analysis. Without access to these capabilities in a single software package, analyzing multiple continuously recorded data streams with

  4. Detection of patient setup errors with a portal image - DRR registration software application.

    Science.gov (United States)

    Sutherland, Kenneth; Ishikawa, Masayori; Bengua, Gerard; Ito, Yoichi M; Miyamoto, Yoshiko; Shirato, Hiroki

    2011-02-18

    The purpose of this study was to evaluate a custom portal image - digitally reconstructed radiograph (DRR) registration software application. The software works by transforming the portal image into the coordinate space of the DRR image using three control points placed on each image by the user, and displaying the fused image. In order to test statistically that the software actually improves setup error estimation, an intra- and interobserver phantom study was performed. Portal images of anthropomorphic thoracic and pelvis phantoms with virtually placed irradiation fields at known setup errors were prepared. A group of five doctors was first asked to estimate the setup errors by examining the portal and DRR image side-by-side, not using the software. A second group of four technicians then estimated the same set of images using the registration software. These two groups of human subjects were then compared with an auto-registration feature of the software, which is based on the mutual information between the portal and DRR images. For the thoracic case, the average distance between the actual setup error and the estimated error was 4.3 ± 3.0 mm for doctors using the side-by-side method, 2.1 ± 2.4 mm for technicians using the registration method, and 0.8 ± 0.4mm for the automatic algorithm. For the pelvis case, the average distance between the actual setup error and estimated error was 2.0 ± 0.5 mm for the doctors using the side-by-side method, 2.5 ± 0.4 mm for technicians using the registration method, and 2.0 ± 1.0 mm for the automatic algorithm. The ability of humans to estimate offset values improved statistically using our software for the chest phantom that we tested. Setup error estimation was further improved using our automatic error estimation algorithm. Estimations were not statistically different for the pelvis case. Consistency improved using the software for both the chest and pelvis phantoms. We also tested the automatic algorithm with a

  5. Optimising the neutron environment of Radiation Portal Monitors: A computational study

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Mark R., E-mail: mark.gilbert@ccfe.ac.uk [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Ghani, Zamir [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); McMillan, John E. [Department of Physics and Astronomy, University of Sheffield, Hicks building, Hounsfield Road, Sheffield S3 7RH (United Kingdom); Packer, Lee W. [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2015-09-21

    Efficient and reliable detection of radiological or nuclear threats is a crucial part of national and international efforts to prevent terrorist activities. Radiation Portal Monitors (RPMs), which are deployed worldwide, are intended to interdict smuggled fissile material by detecting emissions of neutrons and gamma rays. However, considering the range and variety of threat sources, vehicular and shielding scenarios, and that only a small signature is present, it is important that the design of the RPMs allows these signatures to be accurately differentiated from the environmental background. Using Monte-Carlo neutron-transport simulations of a model {sup 3}He detector system we have conducted a parameter study to identify the optimum combination of detector shielding, moderation, and collimation that maximises the sensitivity of neutron-sensitive RPMs. These structures, which could be simply and cost-effectively added to existing RPMs, can improve the detector response by more than a factor of two relative to an unmodified, bare design. Furthermore, optimisation of the air gap surrounding the helium tubes also improves detector efficiency.

  6. Investigation of energy windowing algorithms for effective cargo screening with radiation portal monitors

    International Nuclear Information System (INIS)

    Hevener, Ryne; Yim, Man-Sung; Baird, Ken

    2013-01-01

    Radiation portal monitors (RPMs) are distributed across the globe in an effort to decrease the illicit trafficking of nuclear materials. Many current generation RPMs utilizes large polyvinyltoluene (PVT) plastic scintillators. These detectors are low cost and reliable but have very poor energy resolution. The lack of spectroscopic detail available from PVT spectra has restricted these systems primarily to performing simple gross counting measurements in the past. A common approach to extend the capability of PVT detectors beyond simple “gross-gamma” use is to apply a technique known as energy windowing (EW) to perform rough nuclide identification with limited spectral information. An approach to creating EW algorithms was developed in this work utilizing a specific set of calibration sources and modified EW equations; this algorithm provided a degree of increased identification capability. A simulated real-time emulation of the algorithm utilizing actual port-of-entry RPM data supplied by ORNL provided an extensive proving ground for the algorithm. This algorithm is able to identify four potential threat nuclides and the major NORM source with a high degree of accuracy. High-energy masking, a major detriment of EW algorithms, is reduced by the algorithm's design. - Highlights: • Gross counting algorithms do not produce detailed screenings. • Energy windowing algorithms enhance nuclide identification capability. • Proper use of EW algorithm can identify multiple threat nuclides. • Utilizing specific set of calibration sources is important for nuclide identification

  7. Calculation of neutron die-away times in a large-vehicle portal monitor

    International Nuclear Information System (INIS)

    Lillie, R.A.; Santoro, R.T.; Alsmiller, R.G. Jr.

    1980-05-01

    Monte Carlo methods have been used to calculate neutron die-away times in a large-vehicle portal monitor. These calculations were performed to investigate the adequacy of using neutron die-away time measurements to detect the clandestine movement of shielded nuclear materials. The geometry consisted of a large tunnel lined with He 3 proportional counters. The time behavior of the (n,p) capture reaction in these counters was calculated when the tunnel contained a number of different tractor-trailer load configurations. Neutron die-away times obtained from weighted least squares fits to these data were compared. The change in neutron die-away time due to the replacement of cargo in a fully loaded truck with a spherical shell containing 240 kg of borated polyethylene was calculated to be less than 3%. This result together with the overall behavior of neutron die-away time versus mass inside the tunnel strongly suggested that measurements of this type will not provide a reliable means of detecting shielded nuclear materials in a large vehicle. 5 figures, 4 tables

  8. Rain-Induced Increase in Background Radiation Detected by Radiation Portal Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Hausladen, Paul [ORNL; Blessinger, Christopher S [ORNL; Guzzardo, Tyler [ORNL; Livesay, Jake [ORNL

    2012-07-01

    A complete understanding of both the steady state and transient background measured by Radiation Portal Monitors (RPMs) is essential to predictable system performance, as well as maximization of detection sensitivity. To facilitate this understanding, a test bed for the study of natural background in RPMs has been established at the Oak Ridge National Laboratory. This work was performed in support of the Second Line of Defense Program's mission to detect the illicit movement of nuclear material. In the present work, transient increases in gamma ray counting rates in RPMs due to rain are investigated. The increase in background activity associated with rain, which has been well documented in the field of environmental radioactivity, originates from the atmospheric deposition of two radioactive daughters of radon-222, namely lead-214 and bismuth-214 (henceforth {sup 222}Rn, {sup 214}Pb and {sup 214}Bi). In this study, rainfall rates recorded by a co-located weather station are compared with RPM count rates and High Purity Germanium spectra. The data verifies these radionuclides are responsible for the dominant transient natural background fluctuations in RPMs. Effects on system performance and potential mitigation strategies are discussed.

  9. Design of a New Collimation System to Prevent Interference between X-ray Machines and Radiation Portal Monitors

    International Nuclear Information System (INIS)

    Guzzardo, Tyler; Livesay, Jake

    2012-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) developed a new collimation system that allows radiation portal monitors (RPMs) installed near x-ray machines to operate with a negligible false-positive alarm rate. RPMs are usually installed as far as possible from x-ray machines because false alarms are triggered by escaping x-rays; however, constraints at the installation site sometimes make it necessary that RPMs be installed near x-ray machines. Such RPMs are often plagued by high alarm rates resulting from the simultaneous operation of the RPMs and x-ray machines. Limitations on pedestrian flow, x-ray machine orientation, and RPM location often preclude a simple solution for lowering the alarm rate. Adding additional collimation to the x-ray machines to stop the x-rays at the source can reduce the alarm rate without interfering with site operations or adversely affecting the minimum detectable quantity of material (MDQ). A collimation design has been verified by measurements conducted at a RPM installation site and is applicable to all new and existing RPM installations near x-ray machines.

  10. Lab-Based Measurement of Remediation Techniques for Radiation Portal Monitors (Initial Report)

    International Nuclear Information System (INIS)

    Livesay, Jake

    2012-01-01

    Radiation Portal Monitors (RPM) deployed by the Second Line of Defense (SLD) are known to be sensitive to the natural environmental radioactive background. There are several techniques used to mitigate the effects of background on the monitors, but since the installation environments can vary significantly from one another the need for a standardized, systematic, study of remediation techniques was proposed and carried out. This study is not meant to serve as the absolute last word on the subject. The data collected are, however, intelligible and useful. Some compromises were made, each of which will be described in detail. The hope of this initial report is to familiarize the SLD science teams with ORNL's effort to model the effect of various remediation techniques on simple, static backgrounds. This study provides a good start toward benchmarking the model, and each additional increment of data will serve to make the model more robust. The scope of this initial study is limited to a few basic cases. Its purpose is to prove the utility of lab-based study of remediation techniques and serve as a standard data set for future use. This importance of this first step of standardization will become obvious when science teams are working in parallel on issues of remediation; having a common starting point will do away with one category of difference, thereby making easier the task of determining the sources of disagreement. Further measurements will augment this data set, allowing for further constraint of the universe of possible situations. As will be discussed in the 'Going Forward' section, more data will be included in the final report of this work. Of particular interest will be the data taken with the official TSA lead collimators, which will provide more direct results for comparison with installation data.

  11. Customizable scientific web portal for fusion research

    International Nuclear Information System (INIS)

    Abla, G.; Kim, E.N.; Schissel, D.P.; Flanagan, S.M.

    2010-01-01

    Web browsers have become a major application interface for participating in scientific experiments such as those in magnetic fusion. The recent advances in web technologies motivated the deployment of interactive web applications with rich features. In the scientific world, web applications have been deployed in portal environments. When used in a scientific research environment, such as fusion experiments, web portals can present diverse sources of information in a unified interface. However, the design and development of a scientific web portal has its own challenges. One such challenge is that a web portal needs to be fast and interactive despite the high volume of information and number of tools it presents. Another challenge is that the visual output of the web portal must not be overwhelming to the end users, despite the high volume of data generated by fusion experiments. Therefore, the applications and information should be customizable depending on the needs of end users. In order to meet these challenges, the design and implementation of a web portal needs to support high interactivity and user customization. A web portal has been designed to support the experimental activities of DIII-D researchers worldwide by providing multiple services, such as real-time experiment status monitoring, diagnostic data access and interactive data visualization. The web portal also supports interactive collaborations by providing a collaborative logbook, shared visualization and online instant messaging services. The portal's design utilizes the multi-tier software architecture and has been implemented utilizing web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services, which allows users to create a unique, personalized working environment to fit their own needs and interests. This paper describes the software

  12. Customizable scientific web portal for fusion research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G., E-mail: abla@fusion.gat.co [General Atomics, P.O. Box 85608, San Diego, CA (United States); Kim, E.N.; Schissel, D.P.; Flanagan, S.M. [General Atomics, P.O. Box 85608, San Diego, CA (United States)

    2010-07-15

    Web browsers have become a major application interface for participating in scientific experiments such as those in magnetic fusion. The recent advances in web technologies motivated the deployment of interactive web applications with rich features. In the scientific world, web applications have been deployed in portal environments. When used in a scientific research environment, such as fusion experiments, web portals can present diverse sources of information in a unified interface. However, the design and development of a scientific web portal has its own challenges. One such challenge is that a web portal needs to be fast and interactive despite the high volume of information and number of tools it presents. Another challenge is that the visual output of the web portal must not be overwhelming to the end users, despite the high volume of data generated by fusion experiments. Therefore, the applications and information should be customizable depending on the needs of end users. In order to meet these challenges, the design and implementation of a web portal needs to support high interactivity and user customization. A web portal has been designed to support the experimental activities of DIII-D researchers worldwide by providing multiple services, such as real-time experiment status monitoring, diagnostic data access and interactive data visualization. The web portal also supports interactive collaborations by providing a collaborative logbook, shared visualization and online instant messaging services. The portal's design utilizes the multi-tier software architecture and has been implemented utilizing web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services, which allows users to create a unique, personalized working environment to fit their own needs and interests. This paper describes the software

  13. Customizable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion experiments. Recently in other areas, web portals have begun to be deployed. These portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. The users can create a unique personalized working environment to fit their own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as

  14. Customisable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion. Web portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as Twitter and other social networks. In this series of slides, we describe the software architecture of this scientific web portal and our experiences in utilizing web 2.0 technologies. A

  15. Web-based service portal for decentral power supply systems. Remote monitoring and support of billing; Webbasiertes Service-Portal fuer dezentrale Energieanlagen. Fernueberwachung und Abrechnungsunterstuetzung

    Energy Technology Data Exchange (ETDEWEB)

    Silberg, Peter [EUS GmbH, Holzwickede (Germany); Bernemann, Andrew [MVV Energiedienstleistungen GmbH West, Solingen (Germany); Hillmann, Georg [Tema AG, Berlin (Germany)

    2010-01-15

    Web-based teleservice portals are a good basis for operating data acquisition and control of decentral power generation systems. They also provide a low-cost solution if open-source products are used. The authors present the teleservice portal of MVV Energiedinstleistungen GmbH that was developed by EUS GmbH. (orig.)

  16. Development of natural radiation model for evaluation of background radiation in radiation portal monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Lee, Jin Hyung; Moon, Myung Kook [Radioisotope Research and Development Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-11-15

    In ports and airports, radiation portal monitors (RPM) are deployed to detect illicit radioactive materials. Detected gamma rays in a RPM include background radiation and radiation from a freight. As a vehicle moves through the RPM, the vehicle causes the fluctuations in the natural background radiation signal, which ranges of up to 30%. The fluctuation increases the uncertainty of detection signal and can be a cause of RPM false alarm. Therefore, it is important to evaluate background radiation as well as radiation from a container. In this paper, a natural background radiation model was developed to evaluate RPM. To develop natural background radiation model, a Monte Carlo simulation was performed and compared with experimental measurements from a RPM for {sup 40}K, {sup 232}Th series, and {sup 235}U series, which are major sources of natural background radiation. For a natural radiation source, we considered a cylindrical soil volume with 300 m radius and 1 m depth, which was estimated as the maximum range affecting the RPM by MCNP6 simulation. The volume source model was converted to surface source by using MCNP SSW card for computational efficiency. The computational efficiency of the surface source model was improved to approximately 200 times better than that of the volume source model. The surface source model is composed of a hemisphere with 20 m radius in which the RPM and container are modelled. The natural radiation spectrum from the simulation was best fitted to the experimental measurement when portions of {sup 40}K, {sup 232}Th series, and {sup 235}U series were 0.75, 0.0636, and 0.0552 Bq·g{sup -1}, respectively. For gross counting results, the difference between simulation and experiment was around 5%. The background radiation model was used to evaluate background suppression from a 40 ft container with 7.2 m·s{sup -1} speed. In further study, background models and freight models for RPM in real container ports will be developed and applied to

  17. Hydrological Scenario Using Tools and Applications Available in enviroGRIDS Portal

    Science.gov (United States)

    Bacu, V.; Mihon, D.; Stefanut, T.; Rodila, D.; Cau, P.; Manca, S.; Soru, C.; Gorgan, D.

    2012-04-01

    Nowadays the decision makers but also citizens are concerning with the sustainability and vulnerability of land management practices on various aspects and in particular on water quality and quantity in complex watersheds. The Black Sea Catchment is an important watershed in the Central and East Europe. In the FP7 project enviroGRIDS [1] was developed a Web Portal that incorporates different tools and applications focused on geospatial data management, hydrologic model calibration, execution and visualization and training activities. This presentation highlights, from the end-user point of view, the scenario related with hydrological models using the tools and applications available in the enviroGRIDS Web Portal [2]. The development of SWAT (Soil Water Assessment Tool) hydrological models is a well known procedure for the hydrological specialists [3]. Starting from the primary data (information related to weather, soil properties, topography, vegetation, and land management practices of the particular watershed) that are used to develop SWAT hydrological models, to specific reports, about the water quality in the studied watershed, the hydrological specialist will use different applications available in the enviroGRIDS portal. The tools and applications available through the enviroGRIDS portal are not dealing with the building up of the SWAT hydrological models. They are mainly focused on: calibration procedure (gSWAT [4]) - uses the GRID computational infrastructure to speed-up the calibration process; development of specific scenarios (BASHYT [5]) - starts from an already calibrated SWAT hydrological model and defines new scenarios; execution of scenarios (gSWATSim [6]) - executes the scenarios exported from BASHYT; visualization (BASHYT) - displays charts, tables and maps. Each application is built-up as a stack of functional layers. We combine different layers of applications by vertical interoperability in order to build the desired complex functionality. On

  18. A Web portal for CMS Grid job submission and management

    Energy Technology Data Exchange (ETDEWEB)

    Braun, David [Department of Physics, Purdue University, W. Lafayette, IN 47907 (United States); Neumeister, Norbert, E-mail: neumeist@purdue.ed [Rosen Center for Advanced Computing, Purdue University, W. Lafayette, IN 47907 (United States)

    2010-04-01

    We present a Web portal for CMS Grid submission and management. The portal is built using a JBoss application server. It has a three tier architecture; presentation, business logic and data. Bean based business logic interacts with the underlying Grid infrastructure and pre-existing external applications, while the presentation layer uses AJAX to offer an intuitive, functional interface to the back-end. Application data aggregating information from the portal as well as the external applications is persisted to the server memory cache and then to a backend database. We describe how the portal exploits standard, off-the-shelf commodity software together with existing Grid infrastructures in order to facilitate job submission and monitoring for the CMS collaboration. This paper describes the design, development, current functionality and plans for future enhancements of the portal.

  19. A Web portal for CMS Grid job submission and management

    International Nuclear Information System (INIS)

    Braun, David; Neumeister, Norbert

    2010-01-01

    We present a Web portal for CMS Grid submission and management. The portal is built using a JBoss application server. It has a three tier architecture; presentation, business logic and data. Bean based business logic interacts with the underlying Grid infrastructure and pre-existing external applications, while the presentation layer uses AJAX to offer an intuitive, functional interface to the back-end. Application data aggregating information from the portal as well as the external applications is persisted to the server memory cache and then to a backend database. We describe how the portal exploits standard, off-the-shelf commodity software together with existing Grid infrastructures in order to facilitate job submission and monitoring for the CMS collaboration. This paper describes the design, development, current functionality and plans for future enhancements of the portal.

  20. Portal Hypertension

    Science.gov (United States)

    ... Overview of Gallbladder Cancer Additional Content Medical News Portal Hypertension By Steven K. Herrine, MD, Professor of Medicine, ... Liver Hepatic Encephalopathy Jaundice in Adults Liver Failure Portal Hypertension Portal hypertension is abnormally high blood pressure in ...

  1. The XCAT Science Portal

    Directory of Open Access Journals (Sweden)

    Sriram Krishnan

    2002-01-01

    Full Text Available This paper describes the design and prototype implementation of the XCAT Grid Science Portal. The portal lets grid application programmers script complex distributed computations and package these applications with simple interfaces for others to use. Each application is packaged as a notebook which consists of web pages and editable parameterized scripts. The portal is a workstation-based specialized personal web server, capable of executing the application scripts and launching remote grid applications for the user. The portal server can receive event streams published by the application and grid resource information published by Network Weather Service (NWS [35] or Autopilot [16] sensors. Notebooks can be published and stored in web based archives for others to retrieve and modify. The XCAT Grid Science Portal has been tested with various applications, including the distributed simulation of chemical processes in semiconductor manufacturing and collaboratory support for X-ray crystallographers.

  2. Elimination of quarterly urinalysis of radiation workers based on detection capability of portal monitors for internal contamination

    International Nuclear Information System (INIS)

    Ramanuja, Jayalakshmi

    2012-01-01

    Covidien is a radiopharmaceutical manufacturing company in Missouri, USA. The facility produces radionuclides for diagnostic and therapeutic use. The radionuclides of interest, 123 I, 67 Ga, 99 Mo, 99m Tc, 201 Tl, 111 In, and 131 I are fairly short lived with the exception of 51 Cr. The operating license document for the company mandated quarterly urinalysis (bioassay) of all radiation workers in the facility. This was labor intensive and did not enhance the quality of radiation protection program. Nuclear Regulatory Commission (NRC) required a technical basis to prove that there was no compromise in the radiological safety and accurate dose assessment in the event of internal contamination of radiation workers if quarterly urinalysis was discontinued. Measurements in a phantom, gamma spectroscopy analysis, as well as calculations showed that there was no need to perform quarterly urinalysis and that portal monitors and other radiological controls were sufficient to detect any chronic or acute intake of radioactivity by radiation workers. Technical evaluation showed Portal monitors can detect an Effective Dose Equivalent of 0.1 mSv (10 mrem) in a year. NRC allowed revision of operating license document and operating procedures to discontinue quarterly urinalysis. (author)

  3. Radiation portal evaluation parameters

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    The detection of the unauthorized movement of radioactive materials is one of the most effective nonproliferation measures. Automatic special nuclear material (SNM) portal monitors are designed to detect this unauthorized movement and are an important part of the safeguard systems at US nuclear facilities. SNM portals differ from contamination monitors because they are designed to have high sensitivity for the low energy gamma-rays associated with highly enriched uranium (HEU) and plutonium. These instruments are now being installed at international borders to prevent the spread of radioactive contamination an SNM. In this paper the parameters important to evaluating radiation portal monitors are discussed. (author)

  4. Development of a Ground Water Data Portal for Interoperable Data Exchange within the U.S. National Ground Water Monitoring Network and Beyond

    Science.gov (United States)

    Booth, N. L.; Brodaric, B.; Lucido, J. M.; Kuo, I.; Boisvert, E.; Cunningham, W. L.

    2011-12-01

    The need for a national groundwater monitoring network within the United States is profound and has been recognized by organizations outside government as a major data gap for managing ground-water resources. Our country's communities, industries, agriculture, energy production and critical ecosystems rely on water being available in adequate quantity and suitable quality. To meet this need the Subcommittee on Ground Water, established by the Federal Advisory Committee on Water Information, created a National Ground Water Monitoring Network (NGWMN) envisioned as a voluntary, integrated system of data collection, management and reporting that will provide the data needed to address present and future ground-water management questions raised by Congress, Federal, State and Tribal agencies and the public. The NGWMN Data Portal is the means by which policy makers, academics and the public will be able to access ground water data through one seamless web-based application from disparate data sources. Data systems in the United States exist at many organizational and geographic levels and differing vocabulary and data structures have prevented data sharing and reuse. The data portal will facilitate the retrieval of and access to groundwater data on an as-needed basis from multiple, dispersed data repositories allowing the data to continue to be housed and managed by the data provider while being accessible for the purposes of the national monitoring network. This work leverages Open Geospatial Consortium (OGC) data exchange standards and information models. To advance these standards for supporting the exchange of ground water information, an OGC Interoperability Experiment was organized among international participants from government, academia and the private sector. The experiment focused on ground water data exchange across the U.S. / Canadian border. WaterML2.0, an evolving international standard for water observations, encodes ground water levels and is exchanged

  5. Monitoring Control Applications at CERN

    CERN Document Server

    Bernard, F; Milcent, H; Petrova, L B; Varela, F

    2011-01-01

    The Industrial Controls and Engineering (EN-ICE) group [1] of the Engineering Department at CERN has produced, and is responsible for the operation of around 60 applications, which control critical processes in the domains of cryogenics, quench protection systems, power interlocks for the Large Hadron Collider and other subsystems of the accelerator complex. These applications require 24/7 operation and a quick reaction to problems. For this reason the EN-ICE group is presently developing the Monitoring Operation of cOntrols Networks (MOON) tool to detect, anticipate and inform of possible anomalies in the integrity of the applications. The tool builds on top of Simatic WinCC Open Architecture (WinCC OA) [2] SCADA and makes usage of the Joint COntrols Project (JCOP) [3] and the UNified INdustrial COntrol System (UNICOS) [4] Frameworks developed at CERN. The tool provides centralized monitoring and software management of the different elements integrating the control systems like Windows and L...

  6. Glass fiber sensors for detecting special nuclear materials at portal and monitor stations

    International Nuclear Information System (INIS)

    Hull, C.D.; Seymour, R.; Crawford, T.; Bliss, M.; Craig, R.A.

    2001-01-01

    Nuclear Safeguards and Security Systems LLC (NucSafe) participated in the Illicit Trafficking Radiation Assessment Program (ITRAP) recently conducted by the Austrian Research Center, Seibersdorf (ARCS) for IAEA, INTERPOL, and the World Customs Organization (IAEA, in press). This presentation reviews ITRAP test results of NucSafe instrumentation. NucSafe produces stationary, mobile, and hand-held systems that use neutron and gamma ray sensors to detect Special Nuclear Materials (SNM). Neutron sensors are comprised of scintillating glass fibers (trade name 'PUMA' for Pu Materials Analysis), which provide several advantages over 3 He and 10 BF 3 tubes. PUMA 6 Li glass fiber sensors offer greater neutron sensitivity and dynamic counting range with significantly less microphonic susceptibility than tubes, while eliminating transport and operational hazards. PUMA sensors also cost less per active area than gas tubes, which is important since rapid neutron detection at passenger, freight, and vehicle portals require large sensor areas to provide the required sensitivity

  7. Monitoring control applications at CERN

    International Nuclear Information System (INIS)

    Bernard, F.; Gonzalez, M.; Milcent, H.; Petrova, L.B.; Varela, F.

    2012-01-01

    The Industrial Controls and Engineering (EN-ICE) group of the Engineering Department at CERN has produced, and is responsible for the operation of around 60 applications, which control critical processes in the domains of cryogenics, quench protection systems, power interlocks for the Large Hadron Collider and other subsystems of the accelerator complex. These applications require 24/7 operation and a quick reaction to problems. For this reason the EN-ICE group is presently developing the Monitoring Operation of controls Networks (MOON) tool to detect, anticipate and inform of possible anomalies in the integrity of the applications. The tool builds on top of Simatic WinCC Open Architecture (WinCC OA) SCADA and makes usage of the Joint Controls Project (JCOP) and the Unified Industrial Control System (UNICOS) Frameworks developed at CERN. The tool provides centralized monitoring and software management of the different elements integrating the control systems like Windows and Linux servers, PLCs, applications, etc. Although the primary aim of the monitoring tool is to assist the members of the EN-ICE Standby Service, the tool may offer different levels of detail, which also enables experts to diagnose and troubleshoot problems. In this paper, the scope, functionality and architecture of the tool are presented and some initial results on its performance are summarized. (authors)

  8. Intelligent portal monitor for fast suppression of false positives due to radiopharmaceuticals

    International Nuclear Information System (INIS)

    Johnson, M.W.; Butterfield, K.B.

    1985-01-01

    Monitoring the movement of radioactive material through secure or sensitive areas may be complicated by the existence of unanticipated sources of radiation carried by individuals passing through the area. Typical of such sources are radiopharmaceuticals prescribed for a medical procedure. We report here on an apparatus designed to quickly discriminate between in-vivo radiopharmaceuticals and other nuclear materials, based on a pattern-recognition algorithm and a microcomputer. Principles of operation are discussed, and the data base for the pattern-recognition algorithm is displayed. Operating experience with the apparatus in a trial location is also discussed. Our apparatus correctly identifies in-vivo radiopharmaceuticals in over 80% of all trials; challenges with radioisotopes other than radiopharmaceuticals have led the apparatus, without exception, to reject the challenge isotope as incompatible with medical practice. The apparatus thus rapidly discriminates between individuals bearing radiopharmaceuticals and those bearing illicit sources, such as special nuclear materials. Examples of applications are presented. 7 refs., 4 figs., 1 tab

  9. Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Ruch, Marc L.; Poitrasson-Riviere, Alexis; Sagadevan, Athena; Clarke, Shaun D.; Pozzi, Sara

    2015-07-01

    We present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3He-free radiation portal monitor testing campaign at the European Commission's Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group's system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241Am. Both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

  10. Passive nuclear material detection in a personnel portal

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Eaton, M.J.

    1979-01-01

    The concepts employed in the development of gamma-ray and neutron detection systems for a special nuclear materials booth portal monitor are described. The portal is designed for unattended use in detecting diversion by a technically sophisticated adversary and has possible application to International Atomic Energy Agency safeguards of a fast critical assembly facility. Preliminary evaluation results are given and plans for further parameter studies are noted

  11. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  12. The characteristics of Fugi IP Cassette Type PII and application for radiation oncology quality assurance tests and portal imaging

    International Nuclear Information System (INIS)

    Soh, H.S.; Ung, N.M.; Ng, K.H.

    2008-01-01

    Full text: The advancement of digital imaging has prompted more medical institutions to go filmless. The computed radiography (CR) system is becoming an important tool not only in diagnostic imaging, but also in radiation oncology. A new CR system that was specially designed for the use in radiation oncology. Fuji IP cassette type PII has been introduced to the market in the middle of year 2006. This project aimed to study some basic physical characteristics of this new type of cassette and explore its application for performing quality assurance (QA) tests and portal imaging in radiotherapy. All the images were read by FCR 5000 Plus reader. The image was found to reach its saturation value of 1023 (due to the image was stored in 10 bits data) by depending on the sensitivity value being adjusted. The uniformity test gave the result of 0.12%. The cassette was used to perform the QA tests which were previously performed using film. All the results met the specification as stated in AAPM Task Group 40. The comparison for the portal images of Portal Vision contrast-detail phantom showed that the spatial resolution of the images obtained by CR system (Fujifilm Co.. Ltd.. Tokyo. Japan) were better than the EPID (Varian Medical Systems. Inc.. Palo Alto. USA) and film system (Eastman Kodak Co.. New York. USA). The IP cassette type PII was found to be suitable as an alternative QA test tool and portal imaging in radiotherapy.

  13. MONITORING CONTROL APPLICATIONS AT CERN

    CERN Document Server

    Bernard, F; Milcent, H; Petrova, L B; Varlea, F

    2011-01-01

    The Industrial Controls and Engineering (EN-ICE) group [1] of the Engineering Department at CERN has produced, and is responsible for the operation of around 60 applications, which control critical processes in the domains of cryogenics, quench protection systems, power interlocks for the Large Hadron Collider and other sub-systems of the accelerator complex. These applications require 24/7 operation and a quick reaction to problems. For this reason the EN-ICE group is presently developing the Monitoring Operation of cOntrols Networks (MOON) tool to detect, anticipate and inform of possible anomalies in the integrity of the applications. The tool builds on top of Simatic WinCC Open Architecture (WinCC OA) [2] SCADA and makes usage of the Joint COntrols Project (JCOP) [3] and the UNified INdustrial COntrol System (UNICOS) [4] Frameworks developed at CERN. The tool provides centralized monitoring and software management of the different elements integrating the control systems like Windows and Linux servers, PL...

  14. Quadcopter applications for wildlife monitoring

    Science.gov (United States)

    Radiansyah, S.; Kusrini, M. D.; Prasetyo, L. B.

    2017-01-01

    Recently, Unmanned Aerial Vehicle (UAV) had been use as an instrument for wildlife research. Most of that, using an airplane type which need space for runaway. Copter is UAV type that can fly at canopy space and do not need runaway. The research aims are to examine quadcopter application for wildlife monitoring, measure the accuracy of data generated and determine effective, efficient and appropriate technical recommendation in accordance with the ethics of wildlife photography. Flight trials with a camera 12 - 24 MP at altitude ranges from 50-200 m above ground level (agl), producing aerial photographs with spatial resolution of 0.85 - 4.79 cm/pixel. Aerial photos quality depends on the type and setting of camera, vibration damper system, flight altitude and punctuality of the shooting. For wildlife monitoring the copter is recommended to take off at least 300 m from the target, and flies at 50 - 100 m agl with flight speed of 5 - 7 m/sec on fine weather. Quadcopter presence with a distance more than 30 m from White-bellied Sea Eagles (Haliaeetus leucogaster) nest and Proboscis Monkey (Nasalis larvatus) did not cause negative response. Quadcopter application should pay attention to the behaviour and characteristic of wildlife.

  15. Clinical applications of a high speed matrix ionization chamber portal imaging system

    International Nuclear Information System (INIS)

    Herk, M. van; Gilhuijs, K.; Dalen, A. van; Ven, P. van de; Fencl, W.

    1995-01-01

    A main disadvantage of the present matrix ionization chamber system for electronic portal imaging is its relatively slow image acquisition of 6 s at full resolution. We have solved this problem by modifying the read-out electronics in two ways: First, faster high voltage switches are applied which work with a higher voltage; Second, faster read-out amplifiers are applied which have reduced cross-talk. With these improvements circuit noise is no longer dominant at typical radiotherapy dose rates. Because the quantum noise level in the matrix ionization chamber system is purely determined by signal integration in the liquid medium, the image scan can now be reduced to as short as 0.55 s with little loss of image quality. However, there is some loss of resolution at readout speed faster than 1.5 s due to speed limitations of the read-out amplifiers. One of the applications of the new device is double exposures for larynx fields. At a reduced dose rate of 125 MU/min, only about 5 MUs are required for a single frame on a 4 MV ABB Dynaray accelerator. Other applications which benefit from the reduced image scan time are time lapse movies. Typically 15 frames per field are made during one fraction. The movies offer both information on patient motion and improved image quality by averaging the frames. Finally, on-line analysis of the images can be performed more easily and has been included in the software package. In can be concluded that the higher speed of the new matrix ionization chamber system is an important improvement for several clinical applications

  16. An Approach for harmonizing European Water Portals

    Science.gov (United States)

    Pesquer, Lluís; Stasch, Christoph; Masó, Joan; Jirka, Simon; Domingo, Xavier; Guitart, Francesc; Turner, Thomas; Hinderk Jürrens, Eike

    2017-04-01

    A number of European funded research projects is developing novel solutions for water monitoring, modeling and management. To generate innovations in the water sector, third parties from industry and the public sector need to take up the solutions and bring them into the market. A variety of portals exists to support this move into the market. Examples on the European level are the EIP Water Online Marketplace(1), the WaterInnEU Marketplace(2), the WISE RTD Water knowledge portal(3), the WIDEST- ICT for Water Observatory(4) or the SWITCH-ON Virtual Product Market and Virtual Water-Science Laboratory(5). Further innovation portals and initiatives exist on the national or regional level, for example, the Denmark knows water platform6 or the Dutch water alliance(7). However, the different portals often cover the same projects, the same products and the same services. Since they are technically separated and have their own data models and databases, people need to duplicate information and maintain it at several endpoints. This requires additional efforts and hinders the interoperable exchange between these portals and tools using the underlying data. In this work, we provide an overview on the existing portals and present an approach for harmonizing and integrating common information that is provided across different portals. The approach aims to integrate the common in formation in a common database utilizing existing vocabularies, where possible. An Application Programming Interface allows access the information in a machine-readable way and utilizing the information in other applications beyond description and discovery purposes. (1) http://www.eip-water.eu/my-market-place (2) https://marketplace.waterinneu.org (3) http://www.wise-rtd.info/ (4) http://iwo.widest.eu (5) http://www.switch-on-vwsl.eu/ (6) http://www.rethinkwater.dk/ (7) http://wateralliance.nl/

  17. An intelligent portal monitor for fast suppression of false positives due to radiopharmaceuticals

    International Nuclear Information System (INIS)

    Johnson, M.W.; Butterfield, K.B.

    1985-01-01

    Monitoring the movement of radioactive material through secure or sensitive areas may be complicated by the existence of unanticipated sources of radiation carried by individuals passing through the area. Typical of such sources are radiopharmaceuticals prescribed for a medical procedure. The authors report here on an apparatus designed to quickly discriminate between in-vivo radiopharmaceuticals and other nuclear materials, based on a pattern-recognition algorithm and microcomputer. Principles of operation are discussed, and the data base for the pattern-recognition algorithms is displayed. Operating experience with the apparatus in a trial location is also discussed. The apparatus correctly identifies in-vivo radiopharmaceuticals in over 80% of all trials; challenges with radioisotopes other than radiopharmaceuticals have led the apparatus, without exception, to reject the challenge isotope as incompatible with medical practice. The apparatus thus rapidly discriminates between individuals bearing radiopharmaceuticals and those bearing illicit sources, such as special nuclear materials

  18. Applications guide to pedestrian SNM monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1986-02-01

    The applications guide introduces readers to the pedestrian special nuclear material (SNM) monitors that provide nuclear material control at DOE contractor facilities. It explains the principles of operation, the strong and weak points, and steps for calibration and maintenance of the monitors. Administrators and security specialists will find an overview of pedestrain monitor application and upkeep in Part 1 of the guide and a descriptive catalog of present-day monitors in Part 3. Technically oriented readers will be interested in the more detailed discussion of SNM monitoring physics and SNM monitor design principles found in Part 2. 18 refs., 33 figs., 9 tabs

  19. Applications guide to pedestrian SNM monitors

    Energy Technology Data Exchange (ETDEWEB)

    Fehlau, P.E.

    1986-02-01

    The applications guide introduces readers to the pedestrian special nuclear material (SNM) monitors that provide nuclear material control at DOE contractor facilities. It explains the principles of operation, the strong and weak points, and steps for calibration and maintenance of the monitors. Administrators and security specialists will find an overview of pedestrain monitor application and upkeep in Part 1 of the guide and a descriptive catalog of present-day monitors in Part 3. Technically oriented readers will be interested in the more detailed discussion of SNM monitoring physics and SNM monitor design principles found in Part 2. 18 refs., 33 figs., 9 tabs.

  20. Preliminary Study of Position-Sensitive Large-Area Radiation Portal Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chang Hwy; Kim, Hyunok; Moon, Myung Kook [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Jongyul [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Park, Jong Won; Lim, Yong Kon [Korea Institute of Ocean Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    An RPM, which is a passive inspection method, is a system for monitoring the movement of radioactive materials at an airport, seaport, border, etc. To detect a γ-ray, an RPM using the plastic scintillator is generally used. The method of γ-ray detection using an RPM with a plastic scintillator is to measure lights generated by an incident γ-ray in the scintillator. Generally, a large-area RPM uses one or two photomultiplier tubes (PMT) for light collection. However, in this study, we developed a 4-ch RPM that can measure the radiation signal using 4 PMTs. The reason for using 4 PMTs is to calculate the position of the radiation source. In addition, we developed an electric device for acquisition of a 4-ch output signal at the same time. To estimate the performance of the developed RPM, we performed an RPM test using a {sup 60}Co γ-ray check source. In this study, we performed the development of a 4-ch RPM. The major function of the typical RPM is to measure the radiation. However, we developed a position-sensitive 4-ch RPM, which can be used to measure the location of the radiation source, as well as the radiation measurement, at the same time. In the future, we plan to develop an algorithm for a position detection of the radiation. In addition, an algorithm will be applied to an RPM.

  1. Monitoring obesity prevalence in the United States through bookmarking activities in online food portals.

    Directory of Open Access Journals (Sweden)

    Christoph Trattner

    Full Text Available Studying the impact of food consumption on people's health is a serious matter for its implications on public policy, but it has traditionally been a slow process since it requires information gathered through expensive collection processes such as surveys, census and systematic reviews of research articles. We argue that this process could be supported and hastened using data collected via online social networks. In this work we investigate the relationships between the online traces left behind by users of a large US online food community and the prevalence of obesity in 47 states and 311 counties in the US. Using data associated with the recipes bookmarked over an 9-year period by 144,839 users of the Allrecipes.com food website residing throughout the US, several hierarchical regression models are created to (i shed light on these relations and (ii establish their magnitude. The results of our analysis provide strong evidence that bookmarking activities on recipes in online food communities can provide a signal allowing food and health related issues, such as obesity to be better understood and monitored. We discover that higher fat and sugar content in bookmarked recipes is associated with higher rates of obesity. The dataset is complicated, but strong temporal and geographical trends are identifiable. We show the importance of accounting for these trends in the modeling process.

  2. Monitoring obesity prevalence in the United States through bookmarking activities in online food portals.

    Science.gov (United States)

    Trattner, Christoph; Parra, Denis; Elsweiler, David

    2017-01-01

    Studying the impact of food consumption on people's health is a serious matter for its implications on public policy, but it has traditionally been a slow process since it requires information gathered through expensive collection processes such as surveys, census and systematic reviews of research articles. We argue that this process could be supported and hastened using data collected via online social networks. In this work we investigate the relationships between the online traces left behind by users of a large US online food community and the prevalence of obesity in 47 states and 311 counties in the US. Using data associated with the recipes bookmarked over an 9-year period by 144,839 users of the Allrecipes.com food website residing throughout the US, several hierarchical regression models are created to (i) shed light on these relations and (ii) establish their magnitude. The results of our analysis provide strong evidence that bookmarking activities on recipes in online food communities can provide a signal allowing food and health related issues, such as obesity to be better understood and monitored. We discover that higher fat and sugar content in bookmarked recipes is associated with higher rates of obesity. The dataset is complicated, but strong temporal and geographical trends are identifiable. We show the importance of accounting for these trends in the modeling process.

  3. A user-oriented model for global enterprise portal design

    NARCIS (Netherlands)

    Feng, X.; Ehrenhard, Michel Léon; Hicks, Jeff; Maathuis, Stephanus Johannes; Maathuis, S.J.; Hou, Y.

    2010-01-01

    Enterprise portals collect and synthesise information from various systems to deliver personalised and highly relevant information to users. Enterprise portals' design and applications are widely discussed in the literature; however, the implications of portal design in a global networked

  4. The challenges of knowledge management portals application and implementation:An Iranian organizations case study

    Directory of Open Access Journals (Sweden)

    Sara Sharifi-Yazdi

    2010-07-01

    Full Text Available This article aims to review, identify and prioritize challenge factors of the implementation of knowledge management portals for Iranian organizations. The study determines several important weakness factors affecting the implications of the knowledge management such as the weakness in organizational strategy, information overcrowd, content management, portals project management, and etc. The study also indicates that the factors have different priorities where managerial factors are in the highest priority and financial factors are in the lowest priority. We also perform factor analysis to summarize seventeen factors into six issues: Financial and information security, Technology and management, Senior management support and strategy, Acceptance, User's motivation and culture, Project management, Change management and training. Knowledge management portal is a brand new concept for Iranian organizations and it is hard to gather information from limited number of organizations or companies for applied knowledge management portals. The results of this study could be useful for knowledge management planners and managers in organizations and clear the prospects to deal with the challenges.

  5. Amma - Monitoring and Management Application

    Science.gov (United States)

    Rakesh Adapa, Swamy

    calibrated map is generated each time the satellite data is collected. These maps indicate soil surface moisture, texture, organic matter, photosynthesis stress, water stress, insect stress, nutritional stress and other visible characteristics are used to monitor the crop. Salinity, alkalinity, crop condition assessment and soil wetness levels are found through VNIR and SWIR data that are used for long and short term management of the crop.This application can fulfill the dreams of many small farmers to have their plate full of meal.The hope of UN, ISRO, and MSSRF etc; that the space technology must reach the foot step of the rural people will become true by using our application. We conclude that our application could make the farming sector reach its new fame and heritage.

  6. An applications guide to vehicle SNM monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-03-01

    The applications guide introduces its readers to the vehicle special nuclear material (SNM) monitors that are becoming part of safeguards and security measures for nuclear material control at DOE facilities. Building on the foundation provided by an applications guide to pedestrian SNM monitors published in 1986 and a technical report on vehicle monitoring published in 1982, the guide provides an overview of vehicle monitoring in Part 1, a discussion of technical aspects of vehicle monitoring in Part 2, and a catalog of vehicle SNM monitors available to DOE facilities in Part 3. Vehicle monitor upkeep, calibration, testing, and performance are important topics in Part 1. The short technical discussion in Part 2 is devoted to new developments and unique features of vehicle monitors

  7. An Interactive Mobile Application for the Visually Impaired to Have Access to Listening Audio Books with Handy Books Portal

    Directory of Open Access Journals (Sweden)

    Avanthika Meenakshi

    2015-01-01

    Full Text Available Mobile phones are used in almost all aspects of life by people. But in the case of visually impaired, they are still a step behind in using smart phones for various purposes. Having interactive android OS, navigation and travel aiding apps using sensors and voice user interfaces (VUI or the voice response systems, we are still a step lagging in giving them an application for educational purposes. This paper proposes a complete new idea of having a portal where they can store audio books aided with interactive system so that they can use them whenever needed.

  8. The provider perspective: investigating the effect of the Electronic Patient-Reported Outcome (ePRO) mobile application and portal on primary care provider workflow.

    Science.gov (United States)

    Hans, Parminder K; Gray, Carolyn Steele; Gill, Ashlinder; Tiessen, James

    2018-03-01

    Aim This qualitative study investigates how the Electronic Patient-Reported Outcome (ePRO) mobile application and portal system, designed to capture patient-reported measures to support self-management, affected primary care provider workflows. The Canadian health system is facing an ageing population that is living with chronic disease. Disruptive innovations like mobile health technologies can help to support health system transformation needed to better meet the multifaceted needs of the complex care patient. However, there are challenges with implementing these technologies in primary care settings, in particular the effect on primary care provider workflows. Over a six-week period interdisciplinary primary care providers (n=6) and their complex care patients (n=12), used the ePRO mobile application and portal to collaboratively goal-set, manage care plans, and support self-management using patient-reported measures. Secondary thematic analysis of focus groups, training sessions, and issue tracker reports captured user experiences at a Toronto area Family Health Team from October 2014 to January 2015. Findings Key issues raised by providers included: liability concerns associated with remote monitoring, increased documentation activities due to a lack of interoperability between the app and the electronic patient record, increased provider anxiety with regard to the potential for the app to disrupt and infringe upon appointment time, and increased demands for patient engagement. Primary care providers reported the app helped to focus care plans and to begin a collaborative conversation on goal-setting. However, throughout our investigation we found a high level of provider resistance evidenced by consistent attempts to shift the app towards fitting with existing workflows rather than adapting much of their behaviour. As health systems seek innovative and disruptive models to better serve this complex patient population, provider change resistance will need to

  9. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  10. Magnetic Resonance Imaging of a Liver Hydatid Cyst Invading the Portal Vein and Causing Portal Cavernomatosis.

    Science.gov (United States)

    Herek, Duygu; Sungurtekin, Ugur

    2015-01-01

    Hepatic hydatid cysts rarely invade portal veins causing portal cavernomatosis as a secondary complication. We report the case of a patient with direct invasion of the right portal vein by hydatid cysts causing portal cavernomatosis diagnosed via magnetic resonance imaging (MRI). The presented case highlights the useful application of MRI with T2-weighted images and gadolinium-enhanced T1-weighted images in the diagnosis of hepatic hydatid lesions presenting with a rare complication of portal cavernomatosis.

  11. Evaluation of NaI(TL) and plastic scintillators for use in remote, unattended, and portal monitoring

    International Nuclear Information System (INIS)

    Staples, P.; Audia, J.; Bai, Y.; Briggs, M.; Halbig, J.K.; Ianakiev, K.D.

    1998-01-01

    The authors have evaluated and compared some of the relevant operating characteristics of NaI and plastic scintillators for use in various safeguards monitoring applications. These include a sensitivity analysis of the two scintillators to various radiation fields and scintillator response as affected by environmental temperature. A comparison of experiment and modeling via the Monte Carlo N-Particle (MCNP) code has been performed to validate the calculational techniques. This then enables complex detector situations to be simulated with increased confidence

  12. Comparing a recursive digital filter with the moving-average and sequential probability-ratio detection methods for SNM portal monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1993-01-01

    The author compared a recursive digital filter proposed as a detection method for French special nuclear material monitors with the author's detection methods, which employ a moving-average scaler or a sequential probability-ratio test. Each of these nine test subjects repeatedly carried a test source through a walk-through portal monitor that had the same nuisance-alarm rate with each method. He found that the average detection probability for the test source is also the same for each method. However, the recursive digital filter may have on drawback: its exponentially decreasing response to past radiation intensity prolongs the impact of any interference from radiation sources of radiation-producing machinery. He also examined the influence of each test subject on the monitor's operation by measuring individual attenuation factors for background and source radiation, then ranked the subjects' attenuation factors against their individual probabilities for detecting the test source. The one inconsistent ranking was probably caused by that subject's unusually long stride when passing through the portal

  13. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  14. The EVER-EST portal as support for the Sea Monitoring Virtual Research Community, through the sharing of resources, enabling dynamic collaboration and promoting community engagement

    Science.gov (United States)

    Foglini, Federica; Grande, Valentina; De Leo, Francesco; Mantovani, Simone; Ferraresi, Sergio

    2017-04-01

    EVER-EST offers a framework based on advanced services delivered both at the e-infrastructure and domain-specific level, with the objective of supporting each phase of the Earth Science Research and Information Lifecycle. It provides innovative e-research services to Earth Science user communities for communication, cross-validation and the sharing of knowledge and science outputs. The project follows a user-centric approach: real use cases taken from pre-selected Virtual Research Communities (VRC) covering different Earth Science research scenarios drive the implementation of the Virtual Research Environment (VRE) services and capabilities. The Sea Monitoring community is involved in the evaluation of the EVER-EST infrastructure. The community of potential users is wide and heterogeneous including both multi-disciplinary scientists and national/international agencies and authorities (e.g. MPAs directors, technicians from regional agencies like ARPA in Italy, the technicians working for the Ministry of the Environment) dealing with the adoption of a better way of measuring the quality of the environment. The scientific community has the main role of assessing the best criteria and indicators for defining the Good Environmental Status (GES) in their own sub regions, and implementing methods, protocols and tools for monitoring the GES descriptors. According to the Marine Strategy Framework Directive (MSFD), the environmental status of marine waters is defined by 11 descriptors, and forms a proposed set of 29 associated criteria and 56 different indicators. The objective of the Sea Monitoring VRC is to provide useful and applicable contributions to the evaluation of the descriptors: D1.Biodiversity, D2.Non-indigenous species and D6.Seafloor Integrity (http://ec.europa.eu/environment/marine/good-environmental-status/index_en.htm). The main challenges for the community members are: 1. discovery of existing data and products distributed among different infrastructures; 2

  15. Solarwinds Server & Application Monitor deployment and administration

    CERN Document Server

    Brant, Justin

    2013-01-01

    A concise and practical guide to using SolarWinds Server & Application Monitor.If you are an IT professionals ranging from an entry-level technician to a more advanced network or system administrator who is new to network monitoring services and/or SolarWinds SAM, this book is ideal for you.

  16. A database application for wilderness character monitoring

    Science.gov (United States)

    Ashley Adams; Peter Landres; Simon Kingston

    2012-01-01

    The National Park Service (NPS) Wilderness Stewardship Division, in collaboration with the Aldo Leopold Wilderness Research Institute and the NPS Inventory and Monitoring Program, developed a database application to facilitate tracking and trend reporting in wilderness character. The Wilderness Character Monitoring Database allows consistent, scientifically based...

  17. Development of authentication system for the fast critical assembly (FCA) portal monitor (P/M) and penetration monitor (PN/M) systems of JAERI

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko

    1999-05-01

    The advanced comprehensive containment and surveillance system for the Fast Critical Assembly facility (FCA) of the Japan Atomic Energy Research Institute (JAERI) consists of a Portal monitor (P/M) and a Penetration Monitor (PN/M) systems. The development of these systems was completed in 1988 for alleviating the burdens of manpower and radiation problems in the frequent NDA inspections. After the completion of the field trial test (Phase III), in 1990, the International Atomic Energy Agency (IAEA) accepted the system on condition that an independent IAEA authentication equipment would be provided. The development of the authentication measures was carried out jointly by both the Japan Support Programme for Agency Safeguards (JASPAS) and the U.S. Program of Technical Assistance to IAEA Safeguards (POTAS), and also under the research agreement for the safeguards research and development between JAERI and the US Department of Energy (USDOE). The concept and design requirements of the authentication system were developed by IAEA, but the design and development of the authentication equipment were jointly funded both by JASPAS and POTAS, and also the fund of JAERI was provided for the Sandia National Laboratories (SNL) through USDOE. SNL developed and constructed the authentication system in two phase as Phase I and Phase II. JAERI financed the development of the Phase I and Phase II hardware and software, and the installation of the authentication equipment at the FCA facility, and also carried out the modification of the circuitry and devices for both the P/M and the PN/M systems as well as the reconstruction of the PN/M Junction Unit for compatibility with the implementation of the authentication measures. After the completion of consecutive field trial test of the P/M, the PN/M and the authentication system, IAEA accepted the entire system as an effective and efficient routine inspection measures in 1996. This report describes the modification and reconstruction of

  18. ASH External Web Portal (External Portal) -

    Data.gov (United States)

    Department of Transportation — The ASH External Web Portal is a web-based portal that provides single sign-on functionality, making the web portal a single location from which to be authenticated...

  19. Heart rate monitoring mobile applications

    OpenAIRE

    Chaudhry, Beenish M.

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone?s camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, ?Unique Heart Rate Monitor?, you can also maintain your heart rate history for personal ...

  20. Heart rate monitoring mobile applications.

    Science.gov (United States)

    Chaudhry, Beenish M

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone's camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, 'Unique Heart Rate Monitor', you can also maintain your heart rate history for personal reflection and sharing with a provider.

  1. Portal Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Hakan Demirci

    2016-01-01

    Full Text Available Portal vein thrombosis is an important cause of presinusoidal portal hypertension. Portal vein thrombosis commonly occurs in patient with cirrhosis, malignancy and prothrombotic states. Patients with acute portal vein thrombosis have immediate onset. Patients with chronic portal vein thrombosis have developed portal hypertension and cavernous portal transformation. Portal vein thrombosis is diagnosed with doppler ultrasound, computed tomography and magnetic resonance imaging. Therapy with low molecular weight heparin achieves recanalization in more than half of acute cases.

  2. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  3. The NOAO NVO Portal

    Science.gov (United States)

    Miller, C. J.; Gasson, D.; Fuentes, E.

    2007-10-01

    The NOAO NVO Portal is a web application for one-stop discovery, analysis, and access to VO-compliant imaging data and services. The current release allows for GUI-based discovery of nearly a half million images from archives such as the NOAO Science Archive, the Hubble Space Telescope WFPC2 and ACS instruments, XMM-Newton, Chandra, and ESO's INT Wide-Field Survey, among others. The NOAO Portal allows users to view image metadata, footprint wire-frames, FITS image previews, and provides one-click access to science quality imaging data throughout the entire sky via the Firefox web browser (i.e., no applet or code to download). Users can stage images from multiple archives at the NOAO NVO Portal for quick and easy bulk downloads. The NOAO NVO Portal also provides simplified and direct access to VO analysis services, such as the WESIX catalog generation service. We highlight the features of the NOAO NVO Portal (http://nvo.noao.edu).

  4. Portal manga

    OpenAIRE

    Temprano Hernandez, Joan

    2011-01-01

    El projecte Portal Manga pretén construir una aplicació web que ha de permetre a una empresa anunciar els seus productes a la web, disposar de una botiga virtual en la que es puguin adquirir aquests productes en format digital i finalment un lector web que en permeti la lectura online.

  5. [Application of degree of portal systemic shunting in assessing upper gastrointestinal bleeding in patients with schistosomiasis cirrhosis].

    Science.gov (United States)

    Shuai, Ju; Ying, Li; Chang-Xue, Ji; Biao, Zhang

    2017-03-27

    To discuss the application of the degree of portal systemic shunting in assessing the upper gastrointestinal bleeding in patients with hepatic schistosomiasis. Thirty-three patients with upper gastrointestinal bleeding caused by hepatic schistosomiasis (a bleeding group) and 29 schistosomiasis cirrhosis patients without bleeding (a non-bleeding group) were enrolled as investigation subjects in Jinshan Hospital. The subjects were scanned by the 128 abdominal slice spiral CT. The portal systemic shunting vessels were reconstructed by using thin slab maximum intensity projection (TSMIP) and multiplanar reconstruction (MPR). The degrees of the shunting vessels of the subjects were evaluated and compared, and the relationship between upper gastrointestinal bleeding and the degree of the shunting was analyzed. In the bleeding group, the occurrence rates of the shunting vessels were found as follows: 86.4% in left gastric varices, 68.2% in short gastric varices, 50.0% in esophageal varices, 50.0% in para-esophageal varices, 37.9% in gastric varices, 69.7% in gastric-renal varices, 51.5% in spleen-renal varices, 25.8% in abdominal wall varices, 15.2% in omentum varices, 63.6% in para-splenic varices, 34.8% in umbilical varices, 40.9% in retroperitoneal-paravertebral varices, and 36.4% in mesenteric varices. In the bleeding group, the occurrence rates and the degree of shunt were significantly higher than those in the non-bleeding group in esophageal varices, esophageal vein, left gastric vein and gastric varices (all P upper gastrointestinal bleeding in patients with hepatic schistosomiasis. The patents with higher degree of the shunting vessels have a higher risk of gastrointestinal bleeding.

  6. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  7. Applications for cyber security - System and application monitoring

    International Nuclear Information System (INIS)

    Marron, J. E.

    2006-01-01

    Standard network security measures are adequate for defense against external attacks. However, many experts agree that the greater threat is from internal sources. Insiders with malicious intentions can change controller instructions, change alarm thresholds, and issue commands to equipment which can damage equipment and compromise control system integrity. In addition to strict physical security the state of the system must be continually monitored. System and application monitoring goes beyond the capabilities of network security appliances. It will include active processes, operating system services, files, network adapters and IP addresses. The generation of alarms is a crucial feature of system and application monitoring. The alarms should be integrated to avoid the burden on operators of checking multiple locations for security violations. Tools for system and application monitoring include commercial software, free software, and ad-hoc tools that can be easily created. System and application monitoring is part of a 'defense-in-depth' approach to a control network security plan. Layered security measures prevent an individual security measure failure from being exploited into a successful security breach. Alarming of individual failures is essential for rapid isolation and correction of single failures. System and application monitoring is the innermost layer of this defense strategy. (authors)

  8. Remote sensing applications for monitoring rangeland vegetation ...

    African Journals Online (AJOL)

    Remote sensing techniques hold considerable promise for the inventory and monitoring of natural resources on rangelands. A significant lack of information concerning basic spectral characteristics of range vegetation and soils has resulted in a lack of rangeland applications. The parameters of interest for range condition ...

  9. The NUCLEONICA Nuclear Science Portal

    International Nuclear Information System (INIS)

    Magill, Joseph; Dreher, Raymond

    2009-01-01

    NUCLEONICA (www.nucleonica.net) is a new nuclear science web portal which provides a customisable, integrated environment and collaboration platform using the latest internet 'Web 2.0' technology. NUCLEONICA is aimed at professionals, academics and students working in nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. A unique feature of the portal is the wide range of user friendly web-based nuclear science applications. The portal is also ideal for education and training purposes and as a knowledge management platform to preserve nuclear knowledge built up over many decades.

  10. BRAZILIAN NEWS PORTALS CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    Heloiza G. Herckovitz

    2011-02-01

    Full Text Available A content analysis of four Brazilian news media portals found that economic news dominated the top headlines with little attention paid to education, the environment and welfare. Other trends included a focus on local events and national news sources, reliance on few sources, mostly official ones, and a low percentage of news that fitted the concept of newsworthiness (a combination of both social significance and deviance concepts. Other findings of a study of 432 top news stories published by UOL, Estadão, iG and Terra during a 15-day period between February and March 2008 indicate that the top portions of the portals’ front pages carry news that lacks story depth, editorial branding, and multimedia applications. The results suggest that online news portals are in their infancy although Brazil has the largest online population of Latin America. This study hopes to shed light on the gatekeeping process in Brazilian news portals. Brazilian media portals have yet to become a significant editorial force able to provide knowledge about social issues and public affairs in a socially responsible fashione.

  11. Metagenomic applications in environmental monitoring and bioremediation.

    Science.gov (United States)

    Techtmann, Stephen M; Hazen, Terry C

    2016-10-01

    With the rapid advances in sequencing technology, the cost of sequencing has dramatically dropped and the scale of sequencing projects has increased accordingly. This has provided the opportunity for the routine use of sequencing techniques in the monitoring of environmental microbes. While metagenomic applications have been routinely applied to better understand the ecology and diversity of microbes, their use in environmental monitoring and bioremediation is increasingly common. In this review we seek to provide an overview of some of the metagenomic techniques used in environmental systems biology, addressing their application and limitation. We will also provide several recent examples of the application of metagenomics to bioremediation. We discuss examples where microbial communities have been used to predict the presence and extent of contamination, examples of how metagenomics can be used to characterize the process of natural attenuation by unculturable microbes, as well as examples detailing the use of metagenomics to understand the impact of biostimulation on microbial communities.

  12. The DIRAC Web Portal 2.0

    Science.gov (United States)

    Mathe, Z.; Casajus Ramo, A.; Lazovsky, N.; Stagni, F.

    2015-12-01

    For many years the DIRAC interware (Distributed Infrastructure with Remote Agent Control) has had a web interface, allowing the users to monitor DIRAC activities and also interact with the system. Since then many new web technologies have emerged, therefore a redesign and a new implementation of the DIRAC Web portal were necessary, taking into account the lessons learnt using the old portal. These new technologies allowed to build a more compact, robust and responsive web interface that enables users to have better control over the whole system while keeping a simple interface. The web framework provides a large set of “applications”, each of which can be used for interacting with various parts of the system. Communities can also create their own set of personalised web applications, and can easily extend already existing ones with a minimal effort. Each user can configure and personalise the view for each application and save it using the DIRAC User Profile service as RESTful state provider, instead of using cookies. The owner of a view can share it with other users or within a user community. Compatibility between different browsers is assured, as well as with mobile versions. In this paper, we present the new DIRAC Web framework as well as the LHCb extension of the DIRAC Web portal.

  13. High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging

    International Nuclear Information System (INIS)

    Bel, Arjan; Vos, Pieter H.; Rodrigus, Patrick T. R.; Creutzberg, Carien L.; Visser, Andries G.; Stroom, Joep C.; Lebesque, Joos V.

    1996-01-01

    Purpose: To investigate in three institutions, The Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis [AvL]), Dr. Daniel den Hoed Cancer Center (DDHC), and Dr, Bernard Verbeeten Institute (BVI), how much the patient setup accuracy for irradiation of prostate cancer can be improved by an offline setup verification and correction procedure, using portal imaging. Methods and Materials: The verification procedure consisted of two stages. During the first stage, setup deviations were measured during a number (N max ) of consecutive initial treatment sessions. The length of the average three dimensional (3D) setup deviation vector was compared with an action level for corrections, which shrunk with the number of setup measurements. After a correction was applied, N max measurements had to be performed again. Each institution chose different values for the initial action level (6, 9, and 10 mm) and N max (2 and 4). The choice of these parameters was based on a simulation of the procedure, using as input preestimated values of random and systematic deviations in each institution. During the second stage of the procedure, with weekly setup measurements, the AvL used a different criterion ('outlier detection') for corrective actions than the DDHC and the BVI ('sliding average'). After each correction the first stage of the procedure was restarted. The procedure was tested for 151 patients (62 in AvL, 47 in DDHC, and 42 in BVI) treated for prostate carcinoma. Treatment techniques and portal image acquisition and analysis were different in each institution. Results: The actual distributions of random and systematic deviations without corrections were estimated by eliminating the effect of the corrections. The percentage of mean (systematic) 3D deviations larger than 5 mm was 26% for the AvL and the DDHC, and 36% for the BVI. The setup accuracy after application of the procedure was considerably improved (percentage of mean 3D deviations larger than 5 mm was 1.6% in the

  14. The influence of culture on enterprise portal design in a global environment

    NARCIS (Netherlands)

    Feng, Xiuzhen; Ehrenhard, Michel Léon; Hicks, Jeff; Hou, Yibin; Khosrow-Pour, M.

    2007-01-01

    Enterprise portals collect and synthesize information from various systems to deliver personalized and highly relevant information to suppliers, customers and employees. While enterprise portal design and portal applications have been widely discussed in the literature, the implications that arise

  15. Monitoring system for gamma radiation of porch type for vehicles; Sistema de monitoreo de radiacion gamma tipo portal para vehiculos

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  16. BioPortal: enhanced functionality via new Web services from the National Center for Biomedical Ontology to access and use ontologies in software applications.

    Science.gov (United States)

    Whetzel, Patricia L; Noy, Natalya F; Shah, Nigam H; Alexander, Paul R; Nyulas, Csongor; Tudorache, Tania; Musen, Mark A

    2011-07-01

    The National Center for Biomedical Ontology (NCBO) is one of the National Centers for Biomedical Computing funded under the NIH Roadmap Initiative. Contributing to the national computing infrastructure, NCBO has developed BioPortal, a web portal that provides access to a library of biomedical ontologies and terminologies (http://bioportal.bioontology.org) via the NCBO Web services. BioPortal enables community participation in the evaluation and evolution of ontology content by providing features to add mappings between terms, to add comments linked to specific ontology terms and to provide ontology reviews. The NCBO Web services (http://www.bioontology.org/wiki/index.php/NCBO_REST_services) enable this functionality and provide a uniform mechanism to access ontologies from a variety of knowledge representation formats, such as Web Ontology Language (OWL) and Open Biological and Biomedical Ontologies (OBO) format. The Web services provide multi-layered access to the ontology content, from getting all terms in an ontology to retrieving metadata about a term. Users can easily incorporate the NCBO Web services into software applications to generate semantically aware applications and to facilitate structured data collection.

  17. Lexical Link Analysis Application: Improving Web Service to Acquisition Visibility Portal Phase II

    Science.gov (United States)

    2014-04-30

    bäÉîÉåíÜ=^ååì~ä=^Åèìáëáíáçå= oÉëÉ~êÅÜ=póãéçëáìã= qÜìêëÇ~ó=pÉëëáçåë= sçäìãÉ=ff= = Lexical Link Analysis Application: Improving Web Service to...DATE 30 APR 2014 2. REPORT TYPE 3. DATES COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE Lexical Link Analysis Application: Improving...vocabulary or lexicon, to describe the attributes and surrounding environment of the system. Lexical Link Analysis (LLA) is a form of text mining in which

  18. Lexical Link Analysis Application: Improving Web Service to Acquisition Visibility Portal Phase III

    Science.gov (United States)

    2015-04-30

    ååì~ä=^Åèìáëáíáçå= oÉëÉ~êÅÜ=póãéçëáìã= qÜìêëÇ~ó=pÉëëáçåë= sçäìãÉ=ff= = Lexical Link Analysis Application: Improving Web Service to Acquisition...2015 2. REPORT TYPE 3. DATES COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE Lexical Link Analysis Application: Improving Web Service...processes. Lexical Link Analysis (LLA) can help, by applying automation to reveal and depict???to decisionmakers??? the correlations, associations, and

  19. 1997 update for the applications guide to vehicle SNM monitors

    International Nuclear Information System (INIS)

    York, R.L.; Fehlau, P.E.

    1997-04-01

    Ten years have elapsed since the publication of the original applications guide to vehicle special nuclear material (SNM) monitors. During that interval, use of automatic vehicle monitors has become more commonplace, and formal procedures for monitor upkeep and evaluation have become available. New concepts for vehicle monitoring are being explored, as well. This update report reviews the basics of vehicle SNM monitoring, discusses what is new in vehicle SNM monitoring, and catalogs the vehicle SNM monitors that are commercial available

  20. Noncirrotisk intrahepatisk portal hypertension

    DEFF Research Database (Denmark)

    Dam Fialla, Annette; Havelund, Troels

    2007-01-01

    Non-cirrhotic intrahepatic portal hypertension is characterized by portal hypertension in the absence of liver cirrhosis or portal vein thrombosis. The disease is common in the East and rarely seen in the West. Two cases with oesophageal varices are described. The histopathology is heterogeneous...... but includes vascular lesions and portal fibrosis. Patient management follows the current recommendations for variceal bleeding....

  1. Initiating collaboration among organ transplant professionals through Web portals and mobile applications.

    Science.gov (United States)

    Alexander, Susan; Hoy, Haley; Maskey, Manil; Conover, Helen; Gamble, John; Fraley, Anne

    2013-05-13

    The knowledge base for healthcare providers working in the field of organ transplantation has grown exponentially. However, the field has no centralized 'space' dedicated to efficient access and sharing of information. The ease of use and portability of mobile applications (apps) make them ideal for subspecialists working in complex healthcare environments. In this article, the authors review the literature related to healthcare technology; describe the development of health-related technology; present their mobile app pilot project assessing the effects of a collaborative, mobile app based on a freely available content manage framework; and report their findings. They conclude by sharing both lessons learned while completing this project and future directions.

  2. Access And Monitoring WLAN Using Mobile Application

    Directory of Open Access Journals (Sweden)

    Vaibhav Jori

    2015-08-01

    Full Text Available Abstract Now a days successful functioning of computer networks is important. For that network management systems are very much important. This paper describes the method by using which a LAN network can be controlled by a user with the help of android application. For monitoring and controlling of the various activities of the network the user friendly interface must be created so user should be able to execute many commands to control the activities happening on the network. To connect the phone to the server. Wi-Fi can be used as internet connectivity tool.

  3. Weight monitoring system for newborn incubator application

    Science.gov (United States)

    Widianto, Arif; Nurfitri, Intan; Mahatidana, Pradipta; Abuzairi, Tomy; Poespawati, N. R.; Purnamaningsih., Retno W.

    2018-02-01

    We proposed weight monitoring system using load cell sensor for newborn incubator application. The weight sensing system consists of a load cell, conditioning signal circuit, and microcontroller Arduino Uno R3. The performance of the sensor was investigated by using the various weight from 0 up to 3000 g. Experiment results showed that this system has a small error of 4.313% and 12.5 g of threshold and resolution value. Compared to the typical baby scale available in local market, the proposed system has a lower error value and hysteresis.

  4. The Geo Data Portal an Example Physical and Application Architecture Demonstrating the Power of the "Cloud" Concept.

    Science.gov (United States)

    Blodgett, D. L.; Booth, N.; Walker, J.; Kunicki, T.

    2012-12-01

    The U.S. Geological Survey Center for Integrated Data Analytics (CIDA), in holding with the President's Digital Government Strategy and the Department of Interior's IT Transformation initiative, has evolved its data center and application architecture toward the "cloud" paradigm. In this case, "cloud" refers to a goal of developing services that may be distributed to infrastructure anywhere on the Internet. This transition has taken place across the entire data management spectrum from data center location to physical hardware configuration to software design and implementation. In CIDA's case, physical hardware resides in Madison at the Wisconsin Water Science Center, in South Dakota at the Earth Resources Observation and Science Center (EROS), and in the near future at a DOI approved commercial vendor. Tasks normally conducted on desktop-based GIS software with local copies of data in proprietary formats are now done using browser-based interfaces to web processing services drawing on a network of standard data-source web services. Organizations are gaining economies of scale through data center consolidation and the creation of private cloud services as well as taking advantage of the commoditization of data processing services. Leveraging open standards for data and data management take advantage of this commoditization and provide the means to reliably build distributed service based systems. This presentation will use CIDA's experience as an illustration of the benefits and hurdles of moving to the cloud. Replicating, reformatting, and processing large data sets, such as downscaled climate projections, traditionally present a substantial challenge to environmental science researchers who need access to data subsets and derived products. The USGS Geo Data Portal (GDP) project uses cloud concepts to help earth system scientists' access subsets, spatial summaries, and derivatives of commonly needed very large data. The GDP project has developed a reusable

  5. Cavernous transformation of the portal vein

    International Nuclear Information System (INIS)

    Lehotska, V.; Dostalova, K.; Durkovsky, A.; Samal, V.

    1995-01-01

    In this contribution, the authors give an account of a rare case of a cavernous transformation of the portal vein that may have originated secondarily in a proliferative hematogenous disease with a polyglobulia and thrombosis in the periferal blood count as well as development of portal hypertension of a prehepatal type. The state of hyper-coagulation in a myeloproliferative disease may have lead to a chronic thrombosis of the portal vein with a subsequent malformation of the portal vein in terms of a cavernous transformation of the portal vein. The case is an interesting one because of the discrepancy between the gravity of the thrombotic complication and slightness of the symptoms in the clinical picture. The authors point out the importance of ultrasonography and computed tomography examination following the intravenous application of a water solution of a contrast medium in a morphologic diagnosing of a rare complication of a chronic thrombotic clot of the portal vein - the cavernous transformation. (authors)

  6. Radiation portal monitor with {sup 10}B+ZnS(Ag) neutron detector performance for the detection of special nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Guzman G, K. A.; Gallego, E.; Lorente, A.; Ibanez F, S. [Universidad Politecnica de Madrid, Departamento de Ingenieria Energetica, ETSI Industriales, C. Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Gonzalez, J. A. [Universidad Politecnica de Madrid, Laboratorio de Ingenieria Nuclear, ETSI Caminos, Canales y Puertos, C. Prof. Aranguren 3, 28040 Madrid (Spain); Mendez, R., E-mail: ingkarenguzman@gmail.com [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Laboratorio de Patrones Neutronicos, Av. Complutense 40, 28040 Madrid (Spain)

    2016-10-15

    In homeland security, neutron detection is used to prevent the smuggling of special nuclear materials. Thermal neutrons are normally detected with {sup 3}He proportional counters, in the radiation portal monitors, Rpms, however due to the {sup 3}He shortage new procedures are being studied. In this work Monte Carlo methods, using the MCNP6 code, have been used to study the neutron detection features of a {sup 10}B+ZnS(Ag) under real conditions inside of a Rpm. The performance for neutron detection was carried out for {sup 252}Cf, {sup 238}U and {sup 239}Pu under different conditions. In order to mimic an actual situation occurring at border areas, a sample of SNM sited inside a vehicle was simulated and the Rpm with {sup 10}B+ZnS(Ag) response was calculated. At 200 cm the {sup 10}B+ZnS(Ag) on Rpm response is close to 2.5 cps-ng {sup 252}Cf, when the {sup 252}Cf neutron source is shielded with 0.5 cm-thick lead and 2.5 cm-thick polyethylene fulfilling the ANSI recommendations. Three different geometries of neutron detectors of {sup 10}B+ZnS(Ag) in a neutron detection system in Rpm were modeled. Therefore, the {sup 10}B+ZnS(Ag) detectors are an innovative and viable replacement for the {sup 3}He detectors in the Rpm. (Author)

  7. Radiation portal monitor with "1"0B+ZnS(Ag) neutron detector performance for the detection of special nuclear materials

    International Nuclear Information System (INIS)

    Guzman G, K. A.; Gallego, E.; Lorente, A.; Ibanez F, S.; Vega C, H. R.; Gonzalez, J. A.; Mendez, R.

    2016-10-01

    In homeland security, neutron detection is used to prevent the smuggling of special nuclear materials. Thermal neutrons are normally detected with "3He proportional counters, in the radiation portal monitors, Rpms, however due to the "3He shortage new procedures are being studied. In this work Monte Carlo methods, using the MCNP6 code, have been used to study the neutron detection features of a "1"0B+ZnS(Ag) under real conditions inside of a Rpm. The performance for neutron detection was carried out for "2"5"2Cf, "2"3"8U and "2"3"9Pu under different conditions. In order to mimic an actual situation occurring at border areas, a sample of SNM sited inside a vehicle was simulated and the Rpm with "1"0B+ZnS(Ag) response was calculated. At 200 cm the "1"0B+ZnS(Ag) on Rpm response is close to 2.5 cps-ng "2"5"2Cf, when the "2"5"2Cf neutron source is shielded with 0.5 cm-thick lead and 2.5 cm-thick polyethylene fulfilling the ANSI recommendations. Three different geometries of neutron detectors of "1"0B+ZnS(Ag) in a neutron detection system in Rpm were modeled. Therefore, the "1"0B+ZnS(Ag) detectors are an innovative and viable replacement for the "3He detectors in the Rpm. (Author)

  8. Gd-EOB-DTPA-enhanced MRI for monitoring future liver remnant function after portal vein embolization and extended hemihepatectomy: A prospective trial

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik; Raabe, Philip; Hamm, Bernd; Denecke, Timm [Charite Campus Virchow-Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Luedemann, Lutz [Essen University Hospital, Department of Medical Physics, Essen (Germany); Malinowski, Maciej; Stockmann, Martin; Seehofer, Daniel; Pratschke, Johann [Charite Campus Virchow-Klinikum, Department of General, Visceral and Transplantation Surgery, Berlin (Germany)

    2017-07-15

    To evaluate changes in liver function after right portal vein embolization (PVE) and extended right hemihepatectomy using gadolinium ethoxybenzyl-DTPA-enhanced (Gd-EOB-DTPA) MRI. In this prospective trial, 37 patients undergoing PVE were examined before and 14 and 28 days after PVE and 10 days after extended hemihepatectomy using Gd-EOB-DTPA-enhanced MRI. Lobar volume, kinetic growth rate (KGR), relative enhancement (RE) as well as hepatocellular uptake index (HUI) and fat signal fraction (FSF) were calculated for each lobe. RE of the left liver lobe (LLL) was steadily increasing after PVE and decreased to 0.48 ± 0.19 10 days after surgery, which is significantly lower than 14 days and 28 days post PVE (P < 0.05). KGR was 14.06 ± 9.82%/week for the period from PVE to 14 days after PVE. HUI of the LLL increased steadily after PVE and was significantly higher at both 14 and 28 days after PVE compared to pre PVE (P < 0.05). HUI of the residual liver after surgery was lower than before. Gd-EOB-DTPA-enhanced MRI may be used to monitor the functional increase in the FLR after PVE and to depict the intraoperative liver injury leading to a decrease in liver remnant function. (orig.)

  9. Gd-EOB-DTPA-enhanced MRI for monitoring future liver remnant function after portal vein embolization and extended hemihepatectomy: A prospective trial.

    Science.gov (United States)

    Geisel, Dominik; Raabe, Philip; Lüdemann, Lutz; Malinowski, Maciej; Stockmann, Martin; Seehofer, Daniel; Pratschke, Johann; Hamm, Bernd; Denecke, Timm

    2017-07-01

    To evaluate changes in liver function after right portal vein embolization (PVE) and extended right hemihepatectomy using gadolinium ethoxybenzyl-DTPA-enhanced (Gd-EOB-DTPA) MRI. In this prospective trial, 37 patients undergoing PVE were examined before and 14 and 28 days after PVE and 10 days after extended hemihepatectomy using Gd-EOB-DTPA-enhanced MRI. Lobar volume, kinetic growth rate (KGR), relative enhancement (RE) as well as hepatocellular uptake index (HUI) and fat signal fraction (FSF) were calculated for each lobe. RE of the left liver lobe (LLL) was steadily increasing after PVE and decreased to 0.48 ± 0.19 10 days after surgery, which is significantly lower than 14 days and 28 days post PVE (P DTPA-enhanced MRI may be used to monitor the functional increase in the FLR after PVE and to depict the intraoperative liver injury leading to a decrease in liver remnant function. • The most significant FLR volume increase happens within the first 14 days. • No MRI parameter was able to predict the success of FLR growth. • Our data suggest an early resection about 14 days after PVE. • Routine Gd-EOB-DTPA-enhanced MRI might be suitable to replace ICG-test.

  10. Performance Monitoring Enterprise Applications with the BlackBird System

    Science.gov (United States)

    Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.

    This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.

  11. Impact of spectral smoothing on gamma radiation portal alarm probabilities

    International Nuclear Information System (INIS)

    Burr, T.; Hamada, M.; Hengartner, N.

    2011-01-01

    Gamma detector counts are included in radiation portal monitors (RPM) to screen for illicit nuclear material. Gamma counts are sometimes smoothed to reduce variance in the estimated underlying true mean count rate, which is the 'signal' in our context. Smoothing reduces total error variance in the estimated signal if the bias that smoothing introduces is more than offset by the variance reduction. An empirical RPM study for vehicle screening applications is presented for unsmoothed and smoothed gamma counts in low-resolution plastic scintillator detectors and in medium-resolution NaI detectors. - Highlights: → We evaluate options for smoothing counts from gamma detectors deployed for portal monitoring. → A new multiplicative bias correction (MBC) is shown to reduce bias in peak and valley regions. → Performance is measured using mean squared error and detection probabilities for sources. → Smoothing with the MBC improves detection probabilities and the mean squared error.

  12. The feasible study of vasodilators in portal vein targeting infusion for treating portal hypertension

    International Nuclear Information System (INIS)

    Wu Hanping; Liang Huiming; Zheng Chuansheng; Feng Gansheng

    2002-01-01

    Objective: To find out the ideal portal vein tar getting injection routes for portal hypertension treatment. Methods: 28 cirrhotic rat models with portal hypertension induced by CCl 4 were divided into 4 groups: inferior caval vein injection group, portal vein injection group, hepatic artery injection group, spleen injection group. The changes in portal vein pressure (PVP), inferior caval vein pressure (ICVP), mean artery pressure (MAP) and heart rate (HR) were monitored before and after prazosin injection. Results: After intra-portal, intra-hepatic arterial or spleen injection of prazosin, larger decrease in PVP and lesser effects on MAP than intravenous injection had been induced. The effect on HR showed no difference among these four groups. Conclusions: Hepatic artery and spleen prazosin administration have the same advantages on treatment of portal hypertension as those of intra-portal infusion, that is the greater decrease on portal vein pressure, the lesser effects on systemic hemodynamics. Vasodilation drugs for hepatic artery infusion through percutaneous port catheter system by hepatic artery implantation would be an ideal method for portal hypertension treatment

  13. Idiopathic portal hypertension

    International Nuclear Information System (INIS)

    Han, Tae Kyun; Ryu, Dae Sik; Kim, Heung Chul; Hur, Hun; Eom, Kyeung Tae; Namkung, Sook; Park, Man Soo; Hwang, Woo Chul; Lee, Kwan Seop

    1996-01-01

    To describe the radiologic findings of idiopathic portal hypertension and to find the points of differentiation between idiopathic portal hypertension and liver cirrhosis. Four portograms in five patients who for four years had suffered from pathologically confirmed idiopathic portal hypertension were retrospectively analyzed and compared with a portogram obtained from a control subject with liver cirrhosis. Portographic finding s of idiopathic portal hypertension were paucity of medium-sized portal branches, irregular and obtuse-angled division of peripheral branches, abrupt interruption and an avascular area beneath the liver margin. A portogram of idiopathic portal hypertension may be useful in differentiation this and liver cirrhosis

  14. Rare Disease Video Portal

    OpenAIRE

    Sánchez Bocanegra, Carlos Luis

    2011-01-01

    Rare Disease Video Portal (RD Video) is a portal web where contains videos from Youtube including all details from 12 channels of Youtube. Rare Disease Video Portal (RD Video) es un portal web que contiene los vídeos de Youtube incluyendo todos los detalles de 12 canales de Youtube. Rare Disease Video Portal (RD Video) és un portal web que conté els vídeos de Youtube i que inclou tots els detalls de 12 Canals de Youtube.

  15. A Mobile Application for Monitoring and Management of Depressed Mood in a Vulnerable Pregnant Population.

    Science.gov (United States)

    Hantsoo, Liisa; Criniti, Stephanie; Khan, Annum; Moseley, Marian; Kincler, Naomi; Faherty, Laura J; Epperson, C Neill; Bennett, Ian M

    2018-01-01

    This study tested whether a mood tracking and alert (MTA) mobile application (app) improved mental health care delivery in a high-risk obstetric population. Pregnant women with depressive symptomatology at <32 weeks gestation were followed for eight weeks after randomization to a control patient portal (PP) app alone or with the MTA app. The MTA app monitored activity, assessed mood, and alerted obstetric providers of signs of worsening mood. Seventy-two women enrolled (PP, N=24; MTA, N=48). MTA users had significantly more contacts addressing mental health, and as gestational age increased, they rated ability to manage their own health significantly better than women in the control group. Women who received telephone contact from a provider triggered by an MTA app alert were significantly more likely to receive a mental health specialist referral. A mobile MTA app improved service delivery and patient engagement among patients with perinatal depression symptoms.

  16. User Needs of Digital Service Web Portals: A Case Study

    Science.gov (United States)

    Heo, Misook; Song, Jung-Sook; Seol, Moon-Won

    2013-01-01

    The authors examined the needs of digital information service web portal users. More specifically, the needs of Korean cultural portal users were examined as a case study. The conceptual framework of a web-based portal is that it is a complex, web-based service application with characteristics of information systems and service agents. In…

  17. Ultrasonography for Noninvasive Assessment of Portal Hypertension.

    Science.gov (United States)

    Maruyama, Hitoshi; Yokosuka, Osamu

    2017-07-15

    Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.

  18. The Knowledge Portal

    Data.gov (United States)

    Office of Personnel Management — Information on various courses, as well as personal data of employees and training records from The Knowledge Portal (TKP), a web-based training portal used for the...

  19. Best Practices for Making Scientific Data Discoverable and Accessible through Integrated, Standards-Based Data Portals

    Science.gov (United States)

    Lucido, J. M.

    2013-12-01

    Scientists in the fields of hydrology, geophysics, and climatology are increasingly using the vast quantity of publicly-available data to address broadly-scoped scientific questions. For example, researchers studying contamination of nearshore waters could use a combination of radar indicated precipitation, modeled water currents, and various sources of in-situ monitoring data to predict water quality near a beach. In discovering, gathering, visualizing and analyzing potentially useful data sets, data portals have become invaluable tools. The most effective data portals often aggregate distributed data sets seamlessly and allow multiple avenues for accessing the underlying data, facilitated by the use of open standards. Additionally, adequate metadata are necessary for attribution, documentation of provenance and relating data sets to one another. Metadata also enable thematic, geospatial and temporal indexing of data sets and entities. Furthermore, effective portals make use of common vocabularies for scientific methods, units of measure, geologic features, chemical, and biological constituents as they allow investigators to correctly interpret and utilize data from external sources. One application that employs these principles is the National Ground Water Monitoring Network (NGWMN) Data Portal (http://cida.usgs.gov/ngwmn), which makes groundwater data from distributed data providers available through a single, publicly accessible web application by mediating and aggregating native data exposed via web services on-the-fly into Open Geospatial Consortium (OGC) compliant service output. That output may be accessed either through the map-based user interface or through the aforementioned OGC web services. Furthermore, the Geo Data Portal (http://cida.usgs.gov/climate/gdp/), which is a system that provides users with data access, subsetting and geospatial processing of large and complex climate and land use data, exemplifies the application of International Standards

  20. Customizable scientific web-portal for DIII-D nuclear fusion experiment

    International Nuclear Information System (INIS)

    Abla, G; Kim, E N; Schissel, D P

    2010-01-01

    Increasing utilization of the Internet and convenient web technologies has made the web-portal a major application interface for remote participation and control of scientific instruments. While web-portals have provided a centralized gateway for multiple computational services, the amount of visual output often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments. Since each scientist may have different priorities and areas of interest in the experiment, filtering and organizing information based on the individual user's need can increase the usability and efficiency of a web-portal. DIII-D is the largest magnetic nuclear fusion device in the US. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It offers a customizable interface with personalized page layouts and list of services for users to select. Each individual user can create a unique working environment to fit his own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data analysis and visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, and online instant announcement services. The DIII-D web-portal development utilizes multi-tier software architecture, and Web 2.0 technologies and tools, such as AJAX and Django, to develop a highly-interactive and customizable user interface.

  1. Customizable scientific web-portal for DIII-D nuclear fusion experiment

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E N; Schissel, D P, E-mail: abla@fusion.gat.co [General Atomics, PO Box 85608, San Diego, California 92186-5608 (United States)

    2010-04-01

    Increasing utilization of the Internet and convenient web technologies has made the web-portal a major application interface for remote participation and control of scientific instruments. While web-portals have provided a centralized gateway for multiple computational services, the amount of visual output often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments. Since each scientist may have different priorities and areas of interest in the experiment, filtering and organizing information based on the individual user's need can increase the usability and efficiency of a web-portal. DIII-D is the largest magnetic nuclear fusion device in the US. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It offers a customizable interface with personalized page layouts and list of services for users to select. Each individual user can create a unique working environment to fit his own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data analysis and visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, and online instant announcement services. The DIII-D web-portal development utilizes multi-tier software architecture, and Web 2.0 technologies and tools, such as AJAX and Django, to develop a highly-interactive and customizable user interface.

  2. Customizable scientific web-portal for DIII-D nuclear fusion experiment

    Science.gov (United States)

    Abla, G.; Kim, E. N.; Schissel, D. P.

    2010-04-01

    Increasing utilization of the Internet and convenient web technologies has made the web-portal a major application interface for remote participation and control of scientific instruments. While web-portals have provided a centralized gateway for multiple computational services, the amount of visual output often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments. Since each scientist may have different priorities and areas of interest in the experiment, filtering and organizing information based on the individual user's need can increase the usability and efficiency of a web-portal. DIII-D is the largest magnetic nuclear fusion device in the US. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It offers a customizable interface with personalized page layouts and list of services for users to select. Each individual user can create a unique working environment to fit his own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data analysis and visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, and online instant announcement services. The DIII-D web-portal development utilizes multi-tier software architecture, and Web 2.0 technologies and tools, such as AJAX and Django, to develop a highly-interactive and customizable user interface.

  3. Usability of Discovery Portals

    NARCIS (Netherlands)

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals

  4. Portals people, processes, technology

    CERN Document Server

    Cox, Andrew

    2006-01-01

    First applied to internet gateways such as Yahoo, the concept of the ""portal"" has evolved in a number of directions. How can information services best take advantage of internet portals to improve access to resources? This collection seeks answers to such questions, providing an overview of how portals are being used.

  5. "Smart pebble" design for environmental monitoring applications

    Science.gov (United States)

    Valyrakis, Manousos; Pavlovskis, Edgars

    2014-05-01

    Sediment transport, due to primarily the action of water, wind and ice, is one of the most significant geomorphic processes responsible for shaping Earth's surface. It involves entrainment of sediment grains in rivers and estuaries due to the violently fluctuating hydrodynamic forces near the bed. Here an instrumented particle, namely a "smart pebble", is developed to investigate the exact flow conditions under which individual grains may be entrained from the surface of a gravel bed. This could lead in developing a better understanding of the processes involved, while focusing on the response of the particle during a variety of flow entrainment events. The "smart pebble" is a particle instrumented with MEMS sensors appropriate for capturing the hydrodynamic forces a coarse particle might experience during its entrainment from the river bed. A 3-axial gyroscope and accelerometer registers data to a memory card via a microcontroller, embedded in a 3D-printed waterproof hollow spherical particle. The instrumented board is appropriately fit and centred into the shell of the pebble, so as to achieve a nearly uniform distribution of the mass which could otherwise bias its motion. The "smart pebble" is powered by an independent power to ensure autonomy and sufficiently long periods of operation appropriate for deployment in the field. Post-processing and analysis of the acquired data is currently performed offline, using scientific programming software. The performance of the instrumented particle is validated, conducting a series of calibration experiments under well-controlled laboratory conditions. "Smart pebble" allows for a wider range of environmental sensors (e.g. for environmental/pollutant monitoring) to be incorporated so as to extend the range of its application, enabling accurate environmental monitoring which is required to ensure infrastructure resilience and preservation of ecological health.

  6. Real breakthrough in detection of radioactive sources by portal monitors with plastic detectors and New Advanced Source Identification Algorithm (ASIA-New)

    Energy Technology Data Exchange (ETDEWEB)

    Stavrov, Andrei; Yamamoto, Eugene [Rapiscan Systems, Inc., 14000 Mead Street, Longmont, CO, 80504 (United States)

    2015-07-01

    Radiation Portal Monitors (RPM) with plastic detectors represent the main instruments used for primary border (customs) radiation control. RPM are widely used because they are simple, reliable, relatively inexpensive and have a high sensitivity. However, experience using the RPM in various countries has revealed the systems have some grave shortcomings. There is a dramatic decrease of the probability of detection of radioactive sources under high suppression of the natural gamma background (radiation control of heavy cargoes, containers and, especially, trains). NORM (Naturally Occurring Radioactive Material) existing in objects under control trigger the so-called 'nuisance alarms', requiring a secondary inspection for source verification. At a number of sites, the rate of such alarms is so high it significantly complicates the work of customs and border officers. This paper presents a brief description of new variant of algorithm ASIA-New (New Advanced Source Identification Algorithm), which was developed by the Rapiscan company. It also demonstrates results of different tests and the capability of a new system to overcome the shortcomings stated above. New electronics and ASIA-New enables RPM to detect radioactive sources under a high background suppression (tested at 15-30%) and to verify the detected NORM (KCl) and the artificial isotopes (Co- 57, Ba-133 and other). New variant of ASIA is based on physical principles, a phenomenological approach and analysis of some important parameter changes during the vehicle passage through the monitor control area. Thanks to this capability main advantage of new system is that this system can be easily installed into any RPM with plastic detectors. Taking into account that more than 4000 RPM has been installed worldwide their upgrading by ASIA-New may significantly increase probability of detection and verification of radioactive sources even masked by NORM. This algorithm was tested for 1,395 passages of

  7. From EGEE Operations Portal towards EGI Operations Portal

    Science.gov (United States)

    Cordier, Hélène; L'Orphelin, Cyril; Reynaud, Sylvain; Lequeux, Olivier; Loikkanen, Sinikka; Veyre, Pierre

    Grid operators in EGEE have been using a dedicated dashboard as their central operational tool, stable and scalable for the last 5 years despite continuous upgrade from specifications by users, monitoring tools or data providers. In EGEE-III, recent regionalisation of operations led the Operations Portal developers to conceive a standalone instance of this tool. We will see how the dashboard reorganization paved the way for the re-engineering of the portal itself. The outcome is an easily deployable package customized with relevant information sources and specific decentralized operational requirements. This package is composed of a generic and scalable data access mechanism, Lavoisier; a renowned php framework for configuration flexibility, Symfony and a MySQL database. VO life cycle and operational information, EGEE broadcast and Downtime notifications are next for the major reorganization until all other key features of the Operations Portal are migrated to the framework. Features specifications will be sketched at the same time to adapt to EGI requirements and to upgrade. Future work on feature regionalisation, on new advanced features or strategy planning will be tracked in EGI- Inspire through the Operations Tools Advisory Group, OTAG, where all users, customers and third parties of the Operations Portal are represented from January 2010.

  8. Enterprise Information Management with Plone Portals

    Directory of Open Access Journals (Sweden)

    Marcello Peixoto Bax

    2009-05-01

    Full Text Available The article shows that it is possible to implement a corporate portal using open source software, in an integrated manner with the proprietary MS Windows environment. As it is the real scenario in the vast majority of businesses and organizations today, a portal that meets these specific requirements is highly representative, mainly because MS Windows integration in the client environment (not in the server is not trivial for an open source portal. The paper shows that, by deploying a portal in this context the company considerably moves forward regarding information management. To show this, the article focuses on the key positive aspects arising from the deployment of a intranet / extranet portal in that context, i.e., MS Windows integration; editing with MS Office or other similar applications; shared editing control (with check-in and check-out; universal web access; and the use of metadata and workflow.

  9. Portal hypertensiv gastropati

    DEFF Research Database (Denmark)

    Brinch, K; Møller, S; Henriksen, Jens Henrik Sahl

    1995-01-01

    Portal hypertensive gastropathy (PHG) as defined by congestive changes in the gastric mucosa owing to increased portal pressure, was first described about ten years ago. Whereas definition and grading of severity are still under debate, there is general agreement that PHG is a new clinical entity....... PHG is present in 50-80% of patients with liver cirrhosis. PHG is a major cause of upper gastrointestinal bleeding in patients with portal hypertension (25-90% depending on severity). Presence of portal hypertension is a prerequisite for the development of PHG, and reduction of portal pressure...

  10. Mobile Portal Implementation Strategy

    DEFF Research Database (Denmark)

    Gao, Ping; Damsgaard, Jan

    2005-01-01

    Mobile portal plays an important role in mobile commerce market. Current literature focuses on static analysis on the value chain of mobile portals. This article provides a dynamic perspective on mobile portal strategy. Drawing upon network economics, we describe mobile portal implementation...... as a fourphase process. In different phase, a portal provider has various challenges to overcome and adopt diverse strategies, and correspondingly the regulator has different foci. The conceptual framework proposed in this article offers a basis for further analyses on the market dynamics of mobile commerce......, and can be generalized to studying other networked technologies...

  11. The Anatomy of a Grid portal

    International Nuclear Information System (INIS)

    Licari, Daniele; Calzolari, Federico

    2011-01-01

    In this paper we introduce a new way to deal with Grid portals referring to our implementation. L-GRID is a light portal to access the EGEE/EGI Grid infrastructure via Web, allowing users to submit their jobs from a common Web browser in a few minutes, without any knowledge about the Grid infrastructure. It provides the control over the complete lifecycle of a Grid Job, from its submission and status monitoring, to the output retrieval. The system, implemented as client-server architecture, is based on the Globus Grid middleware. The client side application is based on a java applet; the server relies on a Globus User Interface. There is no need of user registration on the server side, and the user needs only his own X.509 personal certificate. The system is user-friendly, secure (it uses SSL protocol, mechanism for dynamic delegation and identity creation in public key infrastructures), highly customizable, open source, and easy to install. The X.509 personal certificate does not get out from the local machine. It allows to reduce the time spent for the job submission, granting at the same time a higher efficiency and a better security level in proxy delegation and management.

  12. The Anatomy of a Grid portal

    Science.gov (United States)

    Licari, Daniele; Calzolari, Federico

    2011-12-01

    In this paper we introduce a new way to deal with Grid portals referring to our implementation. L-GRID is a light portal to access the EGEE/EGI Grid infrastructure via Web, allowing users to submit their jobs from a common Web browser in a few minutes, without any knowledge about the Grid infrastructure. It provides the control over the complete lifecycle of a Grid Job, from its submission and status monitoring, to the output retrieval. The system, implemented as client-server architecture, is based on the Globus Grid middleware. The client side application is based on a java applet; the server relies on a Globus User Interface. There is no need of user registration on the server side, and the user needs only his own X.509 personal certificate. The system is user-friendly, secure (it uses SSL protocol, mechanism for dynamic delegation and identity creation in public key infrastructures), highly customizable, open source, and easy to install. The X.509 personal certificate does not get out from the local machine. It allows to reduce the time spent for the job submission, granting at the same time a higher efficiency and a better security level in proxy delegation and management.

  13. An illustrative application example: cargo state monitoring

    NARCIS (Netherlands)

    van Leeuwen, C.; Diaz, V.C.; Kotian, R.; del Toro Matamoros, R.; Papp, Z.; Rieter-Barrel, Y.; Papp, Z.; Exarchakos, G.

    2016-01-01

    This chapter describes a real self-adaptive system carried out using the DEMANES tool chain. This chapter focuses on the design and implementation stages of a real use case development. The use case under study is a subsystem, called Cargo Monitoring System (CMS) , that monitors the state of the

  14. Application of radiophotoluminescence dosemeters for environmental monitoring

    International Nuclear Information System (INIS)

    Mihara, A.; Tamura, T.; Mochizuki, T.; Numakunai, T.; Yoshida, Y.; Ohi, Y.

    1993-01-01

    Feasibility study has been made on the radiofluorescence glass (RPL) dosemeters for environmental radiation monitoring. Main items in the laboratory tests are batch uniformities of pre-dose and sensitivity, build-up characteristics of RPL intensity, energy and angular responses, stabilities for RPL reading, anneal cycling and climatic conditional changes. We have determined self-irradiation dose and cosmic ray contribution. Radiation monitoring field test for the RPL dosemeters has been conducted in comparison with the present TLD systems. A procedure manual for the environmental monitoring by the use of RPL dosemeters is in preparation

  15. Biosensors and invasive monitoring in clinical applications

    CERN Document Server

    Córcoles, Emma P

    2013-01-01

    This volume examines the advances of invasive monitoring by means of biosensors and microdialysis. Physical and physiological parameters are commonly monitored in clinical settings using invasive techniques due to their positive outcome in patients’ diagnosis and treatment. Biochemical parameters, however, still rely on off-line measurements and require large pieces of equipment. Biosensing and sampling devices present excellent capabilities for their use in continuous monitoring of patients’ biochemical parameters. However, certain issues remain to be solved in order to ensure a more widespread use of these techniques in today’s medical practices.

  16. Trajectory Clustering with Applications to Airspace Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — This paper presents a framework aimed at monitoring the behavior of aircraft in a given airspace. Trajectories that constitute typical operations are determined and...

  17. Noncirrhotic portal hypertension.

    Science.gov (United States)

    Da, Ben L; Koh, Christopher; Heller, Theo

    2018-05-01

    Noncirrhotic portal hypertension represents a heterogeneous group of liver disorders that is characterized by portal hypertension in the absence of cirrhosis. The purpose of this review is to serve as a guide on how to approach a patient with noncirrhotic portal hypertension with a focus on recent developments. Recent studies pertaining to noncirrhotic portal hypertension have investigated aetiological causes, mechanisms of disease, noninvasive diagnostic modalities, clinical characteristics in the paediatric population and novel treatment targets. Noncirrhotic portal hypertension is an underappreciated clinical entity that can be difficult to diagnosis without a healthy suspicion. Diagnosis then relies on a comprehensive understanding of the causes and clinical manifestations of this disease, as well as a careful interpretation of the liver biopsy. Noninvasive approaches to diagnosis may play a significant role moving forward in this disease. Treatment in NCPH remains largely targeted at the individual sequalae of portal hypertension.

  18. Hepatic angiography: Portal hypertension

    International Nuclear Information System (INIS)

    Oliver, T.W. Jr.; Sones, P.J. Jr.

    1985-01-01

    Portal hypertension is usually a manifestation of underlying hepatic parenchymal disease, although it may be secondary to portal or hepatic venous thrombosis and rarely to hyperdynamic portal states. Portal hypertension may present as encephalopathy, ascites, jaundice, hepatic failure, or catastrophic upper gastrointestinal hemorrhage. Radiologic investigation should include indirect or direct measurements of portal pressure, assessment of portal venous perfusion, visualization of collaterals, and demonstration of arterial and venous anatomy for potential shunt procedure. Following survival of initial variceal bleeding, the most effective procedure to prevent recurrent hemorrhage is a shunt to decompress the varices. The decision whether to intervene medically or surgically during the acute hemorrhagic episode as well as the type of shunt used to prevent future hemorrhage is the subject of continuing controversy

  19. Pediatric portal hypertension

    Science.gov (United States)

    Vogel, Clarissa Barbon

    2017-01-01

    Abstract: Pediatric portal hypertension management is a team approach between the patient, the patient's family, the primary caregiver, and specialty providers. Evidence-based practice guidelines have not been established in pediatrics. This article serves as a review for the primary care NP in the management of pediatric portal hypertension, discussing the etiology, pathophysiology, and clinical presentation of pediatric portal hypertension, diagnostic tests, and treatment and management options. PMID:28406835

  20. Usability of Discovery Portals

    OpenAIRE

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals are not spatial data experts but professionals with limited spatial knowledge, and a focus outside the spatial domain. An exploratory usability experiment was carried out in which three discovery p...

  1. Characteristics and applications of small, portable gaseous air pollution monitors.

    Science.gov (United States)

    McKercher, Grant R; Salmond, Jennifer A; Vanos, Jennifer K

    2017-04-01

    Traditional approaches for measuring air quality based on fixed measurements are inadequate for personal exposure monitoring. To combat this issue, the use of small, portable gas-sensing air pollution monitoring technologies is increasing, with researchers and individuals employing portable and mobile methods to obtain more spatially and temporally representative air pollution data. However, many commercially available options are built for various applications and based on different technologies, assumptions, and limitations. A review of the monitor characteristics of small, gaseous monitors is missing from current scientific literature. A state-of-the-art review of small, portable monitors that measure ambient gaseous outdoor pollutants was developed to address broad trends during the last 5-10 years, and to help future experimenters interested in studying gaseous air pollutants choose monitors appropriate for their application and sampling needs. Trends in small, portable gaseous air pollution monitor uses and technologies were first identified and discussed in a review of literature. Next, searches of online databases were performed for articles containing specific information related to performance, characteristics, and use of such monitors that measure one or more of three criteria gaseous air pollutants: ozone, nitrogen dioxide, and carbon monoxide. All data were summarized into reference tables for comparison between applications, physical features, sensing capabilities, and costs of the devices. Recent portable monitoring trends are strongly related to associated applications and audiences. Fundamental research requires monitors with the best individual performance, and thus the highest cost technology. Monitor networking favors real-time capabilities and moderate cost for greater reproduction. Citizen science and crowdsourcing applications allow for lower-cost components; however important strengths and limitations for each application must be addressed

  2. BSD Portals for LINUX 2.0

    Science.gov (United States)

    McNab, A. David; woo, Alex (Technical Monitor)

    1999-01-01

    Portals, an experimental feature of 4.4BSD, extend the file system name space by exporting certain open () requests to a user-space daemon. A portal daemon is mounted into the file name space as if it were a standard file system. When the kernel resolves a pathname and encounters a portal mount point, the remainder of the path is passed to the portal daemon. Depending on the portal "pathname" and the daemon's configuration, some type of open (2) is performed. The resulting file descriptor is passed back to the kernel which eventually returns it to the user, to whom it appears that a "normal" open has occurred. A proxy portalfs file system is responsible for kernel interaction with the daemon. The overall effect is that the portal daemon performs an open (2) on behalf of the kernel, possibly hiding substantial complexity from the calling process. One particularly useful application is implementing a connection service that allows simple scripts to open network sockets. This paper describes the implementation of portals for LINUX 2.0.

  3. Dose patient verification during treatment using an amorphous silicon electronic portal imaging device in radiotherapy

    International Nuclear Information System (INIS)

    Berger, Lucie

    2006-01-01

    Today, amorphous silicon electronic portal imaging devices (aSi EPID) are currently used to check the accuracy of patient positioning. However, they are not use for dose reconstruction yet and more investigations are required to allow the use of an aSi EPID for routine dosimetric verification. The aim of this work is first to study the dosimetric characteristics of the EPID available at the Institut Curie and then, to check patient dose during treatment using these EPID. First, performance optimization of the Varian aS500 EPID system is studied. Then, a quality assurance system is set up in order to certify the image quality on a daily basis. An additional study on the dosimetric performance of the aS500 EPID is monitored to assess operational stability for dosimetry applications. Electronic portal imaging device is also a useful tool to improve IMRT quality control. The validation and the quality assurance of a portal dose image prediction system for IMRT pre-treatment quality control are performed. All dynamic IMRT fields are verified in clinical routine with the new method based on portal dosimetry. Finally, a new formalism for in vivo dosimetry using transit dose measured with EPID is developed and validated. The absolute dose measurement issue using aSi EPID is described and the midplane dose determination using in vivo dose measurements in combination with portal imaging is used with 3D-conformal-radiation therapy. (author) [fr

  4. Application of GPRS and GIS in Boiler Remote Monitoring System

    OpenAIRE

    Hongchao Wang; Yifeng Wu

    2012-01-01

    Application of GPRS and GIS in boiler remote monitoring system was designed in this paper by combining the advantage of GPRS and GIS in remote data transmission with configuration monitoring technology. The detail information of the operating conditions of the industrial boiler can be viewed by marking the location of boiler on the electronic map dynamically which can realize the unified management for industrial boiler of a region or city conveniently. Experimental application show that the ...

  5. ESP8266 WI-FI MODULE FOR MONITORING SYSTEM APPLICATION

    OpenAIRE

    Tae-Gue Oh; Chung-Hyuk Yim; Gyu-Sik Kim

    2017-01-01

    The ESP8266 Wi-Fi module is a self-contained system-on-chip (SOC) with integrated TCP/IP protocol stacks that can give any microcontroller access to a Wi-Fi network. In this paper, the interface between the ESP8266 Wi-Fi module and arduino MCU is studied for monitoring system application. Through some experimental studies, we believe that the ESP8266 Wi-Fi module is very useful for monitoring system application.

  6. Portal Vein Embolization with Contralateral Application of Stem Cells Facilitates Increase of Future Liver Remnant Volume in Patients with Liver Metastases

    International Nuclear Information System (INIS)

    Ludvík, Jaroslav; Duras, Petr; Třeška, Vladislav; Matoušková, Táňa; Brůha, Jan; Fichtl, Jakub; Lysák, Daniel; Ferda, Jiří; Baxa, Jan

    2017-01-01

    ObjectivesThis study aimed to evaluate the progress of future liver remnant volume (FLRV) in patients with liver metastases after portal vein embolization (PVE) with the application of hematopoietic stem cells (HSCs) and compare it with a patients control group after PVE only.MethodsTwenty patients (group 1) underwent PVE with contralateral HSC application. Subsequently, CT volumetry with the determination of FLRV was performed at weekly intervals, in total three weeks. A sample of twenty patients (group 2) who underwent PVE without HSC application was used as a control group.ResultsThe mean of FLRV increased by 173.2 mL during three weeks after the PVE/HSC procedure, whereas by 98.9 mL after PVE only (p = 0.015). Furthermore, the mean daily growth of FLRV by 7.6 mL in group 1 was significantly higher in comparison with 4.1 mL in group 2 (p = 0.007).ConclusionsPVE with the application of HSC significantly facilitates growth of FLRV in comparison with PVE only. This method could be one of the new suitable approaches to increase the resectability of liver tumours.

  7. Portal Vein Embolization with Contralateral Application of Stem Cells Facilitates Increase of Future Liver Remnant Volume in Patients with Liver Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Ludvík, Jaroslav, E-mail: ludvikj@fnplzen.cz; Duras, Petr [Charles University, Department of Imaging Methods, University Hospital and Faculty of Medicine in Pilsen (Czech Republic); Třeška, Vladislav [Charles University, Department of Surgery, University Hospital and Faculty of Medicine in Pilsen (Czech Republic); Matoušková, Táňa [Charles University, Department of Imaging Methods, University Hospital and Faculty of Medicine in Pilsen (Czech Republic); Brůha, Jan; Fichtl, Jakub [Charles University, Department of Surgery, University Hospital and Faculty of Medicine in Pilsen (Czech Republic); Lysák, Daniel [Charles University, Department of Haemato-Oncology, University Hospital and Faculty of Medicine in Pilsen (Czech Republic); Ferda, Jiří; Baxa, Jan [Charles University, Department of Imaging Methods, University Hospital and Faculty of Medicine in Pilsen (Czech Republic)

    2017-05-15

    ObjectivesThis study aimed to evaluate the progress of future liver remnant volume (FLRV) in patients with liver metastases after portal vein embolization (PVE) with the application of hematopoietic stem cells (HSCs) and compare it with a patients control group after PVE only.MethodsTwenty patients (group 1) underwent PVE with contralateral HSC application. Subsequently, CT volumetry with the determination of FLRV was performed at weekly intervals, in total three weeks. A sample of twenty patients (group 2) who underwent PVE without HSC application was used as a control group.ResultsThe mean of FLRV increased by 173.2 mL during three weeks after the PVE/HSC procedure, whereas by 98.9 mL after PVE only (p = 0.015). Furthermore, the mean daily growth of FLRV by 7.6 mL in group 1 was significantly higher in comparison with 4.1 mL in group 2 (p = 0.007).ConclusionsPVE with the application of HSC significantly facilitates growth of FLRV in comparison with PVE only. This method could be one of the new suitable approaches to increase the resectability of liver tumours.

  8. Portal cholangiopathy: case report

    Directory of Open Access Journals (Sweden)

    Maria Cecilia Almeida Maia

    2014-01-01

    Full Text Available The present report describes the case of a child that after blunt abdominal trauma presented with portal thrombosis followed by progressive splenomegaly and jaundice. Ultrasonography and percutaneous cholangiography revealed biliary dilatation secondary to choledochal stenosis caused by dilated peribiliary veins, characterizing a case of portal biliopathy. The present case report is aimed at presenting an uncommon cause of this condition.

  9. Nuclear Accidents Archive Knowledge Organization System Portal “NAAKOS”: An Application of Semantic Technologies in the Nuclear Domain

    International Nuclear Information System (INIS)

    Atieh, T.

    2016-01-01

    Full text: In line with the IAEA Action Plan on Nuclear Safety, the IAEA was requested to assist Member States enhancing transparency and effectiveness of communication among operators, regulators and various international organizations, and supporting wide dissemination of safety related technical information on nuclear safety. In this context, the IAEA was further asked to analyse and preserve lessons learned from the Fukushima Daiichi NPP accident, as well as from past major incidents and radiological events. The IAEA NKM Section has launched the Nuclear Accidents Repository Portal Knowledge Organization System “NAAKOS” initiative which aims at collecting and preserving data, information, and knowledge related to nuclear accidents and making this knowledge available through one single access point, while ensuring their long term preservation. The NKM Section has developed the Nuclear Accidents Taxonomy which will be used, along other nuclear taxonomies, to enhance information retrieval. It would also include the use of semantic technologies, data mining and linked data to support users beyond the traditional search facilities. The overall objective is to assist to find predefined measures in a timely manner that could prevent, or at least minimize the adverse effects of incidents. (author

  10. Exotic energy injection with ExoCLASS: application to the Higgs portal model and evaporating black holes

    Science.gov (United States)

    Stöcker, Patrick; Krämer, Michael; Lesgourgues, Julien; Poulin, Vivian

    2018-03-01

    We devise a new user-friendly tool interfaced with the Boltzmann code CLASS to deal with any kind of exotic electromagnetic energy injection in the universe and its impact on anisotropies of the Cosmic Microwave Background. It makes use of the results from standard electromagnetic cascade calculations develop in the context of WIMP annihilation, generalized to incorporate any injection history. We first validate it on a specific WIMP scenario, the Higgs Portal model, confirming that the standard effective on-the-spot treatment is accurate enough. We then analyze the more involved example of evaporating Primordial Black Holes (PBHs) with masses in the range [3×1013,5×1016] g, for which the standard approximations break down. We derive robust CMB bounds on the relic density of evaporating PBHs, ruling out the possibility for PBHs with a monochromatic distribution of masses in the range [3×1013,2.5×1016] g to represent all of the Dark Matter in our Universe. Remarkably, we confirm with an accurate study that the CMB bounds are several orders of magnitude stronger than those from the galactic gamma-ray background in the range [3×1013,3×1014] g. A future CMB experiment like CORE+, or an experiment attempting at measuring the 21 cm signal from the Dark Ages could greatly improve the sensitivity to these models.

  11. Portal Vein Stenting for Portal Biliopathy with Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dongho, E-mail: mesentery@naver.com; Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center (Korea, Republic of); Lim, Seong Joo [Konyang University, Department of Radiology, College of Medicine, Konyang University Hospital (Korea, Republic of); Hwang, Jin Ho [Hallym University Sacred Heart Hospital, Department of Radiology (Korea, Republic of); Sinn, Dong Hyun [Sungkyunkwan University School of Medicine, Department of Medicine, Samsung Medical Center (Korea, Republic of)

    2016-04-15

    Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

  12. Portal vein thrombosis.

    Science.gov (United States)

    Chawla, Yogesh K; Bodh, Vijay

    2015-03-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion.

  13. Algorithms and Applications in Grass Growth Monitoring

    Directory of Open Access Journals (Sweden)

    Jun Liu

    2013-01-01

    Full Text Available Monitoring vegetation phonology using satellite data has been an area of growing research interest in recent decades. Validation is an essential issue in land surface phenology study at large scale. In this paper, double logistic function-fitting algorithm was used to retrieve phenophases for grassland in North China from a consistently processed Moderate Resolution Spectrodiometer (MODIS dataset. Then, the accuracy of the satellite-based estimates was assessed using field phenology observations. Results show that the method is valid to identify vegetation phenology with good success. The phenophases derived from satellite and observed on ground are generally similar. Greenup onset dates identified by Normalized Difference Vegetation Index (NDVI and in situ observed dates showed general agreement. There is an excellent agreement between the dates of maturity onset determined by MODIS and the field observations. The satellite-derived length of vegetation growing season is generally consistent with the surface observation.

  14. Liver Regeneration After Portal Vein Embolization Using Absorbable and Permanent Embolization Materials in a Rabbit Model

    NARCIS (Netherlands)

    van den Esschert, Jacomina W.; van Lienden, Krijn P.; Alles, Lindy K.; van Wijk, Albert C.; Heger, Michal; Roelofs, Joris J.; van Gulik, Thomas M.

    2012-01-01

    Objective: To compare the safety and hypertrophy response after portal vein embolization (PVE) using 2 absorbable and 3 permanent embolization materials. Background: Portal vein embolization is used to increase future remnant liver volume preoperatively. Application of temporary, absorbable

  15. A chess web portal

    OpenAIRE

    Volf, Žiga

    2011-01-01

    The aim of the thesis was to develop a web portal for chess players, which is intended to be a place for quality chess joining over the Internet and chess education. This need is caused by existing social networks and websites for playing chess, which offer you a very small amount of quality chess joining and education. As a result of the work the chess portal was created. We have presented the development of the chess portal in the thesis, which has all the features the chess players are i...

  16. A sensor monitoring system for telemedicine, safety and security applications

    Science.gov (United States)

    Vlissidis, Nikolaos; Leonidas, Filippos; Giovanis, Christos; Marinos, Dimitrios; Aidinis, Konstantinos; Vassilopoulos, Christos; Pagiatakis, Gerasimos; Schmitt, Nikolaus; Pistner, Thomas; Klaue, Jirka

    2017-02-01

    A sensor system capable of medical, safety and security monitoring in avionic and other environments (e.g. homes) is examined. For application inside an aircraft cabin, the system relies on an optical cellular network that connects each seat to a server and uses a set of database applications to process data related to passengers' health, safety and security status. Health monitoring typically encompasses electrocardiogram, pulse oximetry and blood pressure, body temperature and respiration rate while safety and security monitoring is related to the standard flight attendance duties, such as cabin preparation for take-off, landing, flight in regions of turbulence, etc. In contrast to previous related works, this article focuses on the system's modules (medical and safety sensors and associated hardware), the database applications used for the overall control of the monitoring function and the potential use of the system for security applications. Further tests involving medical, safety and security sensing performed in an real A340 mock-up set-up are also described and reference is made to the possible use of the sensing system in alternative environments and applications, such as health monitoring within other means of transport (e.g. trains or small passenger sea vessels) as well as for remotely located home users, over a wired Ethernet network or the Internet.

  17. Radon detectors for continuous environmental monitoring applications

    International Nuclear Information System (INIS)

    Sisoutham, O.; Werczynski, S.; Chambers, S.; Zahorowski, W.

    2003-01-01

    The two-filter method is presently the best technique available for real-time low-level counting of atmospheric 222 Rn. The Australian Nuclear Science and Technology Organisation has developed and deployed a range of dual flow loop, two-filter radon detectors around the world for various applications. The detectors have a response time of 45 minutes, and can be custom built for specific purposes. The largest detectors have a lower limit of detection of ∼10 mBq m -3

  18. ECG Holter monitor with alert system and mobile application

    Science.gov (United States)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  19. Current applications of vibration monitoring and neutron noise analysis

    International Nuclear Information System (INIS)

    Damiano, B.; Kryter, R.C.

    1990-02-01

    Monitoring programs using vibration monitoring or neutron noise analysis have demonstrated the ability to detect and, in some cases, diagnose the nature of reactor vessel internals structural degradation. Detection of compromised mechanical integrity of reactor vessel internal components in its early stages allows corrective action to be taken before weakening or damage occurs. In addition to the economic benefits early detection and correction can provide, they can also help maintain plant safety. Information on the condition of reactor vessel internal components gained from a monitoring program supplements in-service inspection results and may be useful in justifying plant license extension. This report, which was prepared under the Nuclear Plant Aging Research Program sponsored by the US Nuclear Regulatory Commission, discusses the application of vibration monitoring and neutron noise analysis for monitoring light-water reactor vessel internals. The report begins by describing the effects of structural integrity loss on internals vibration and how measurable parameters can be used to detect and track the progress of degradation. This is followed by a description and comparison of vibration monitoring and neutron noise analysis, two methods for monitoring the mechanical integrity of reactor vessel internals condition monitoring programs in the United States, Federal Republic of Germany, and France, three countries having substantial commitments to nuclear power. The last section presents guidelines for US utilities wishing to establish reactor internals condition monitoring programs. 20 refs., 5 figs., 4 tabs

  20. Condition Monitoring Of Operating Pipelines With Operational Modal Analysis Application

    OpenAIRE

    Mironov Aleksey; Doronkin Pavel; Priklonsky Aleksander; Kabashkin Igor

    2015-01-01

    In the petroleum, natural gas and petrochemical industries, great attention is being paid to safety, reliability and maintainability of equipment. There are a number of technologies to monitor, control, and maintain gas, oil, water, and sewer pipelines. The paper focuses on operational modal analysis (OMA) application for condition monitoring of operating pipelines. Special focus is on the topicality of OMA for definition of the dynamic features of the pipeline (frequencies and mode shapes) i...

  1. CREM monitoring: a wireless RF application

    Science.gov (United States)

    Valencia, J. D.; Burghard, B. J.; Skorpik, J. R.; Silvers, K. L.; Schwartz, M. J.

    2005-05-01

    Recent security lapses within the Department of Energy laboratories prompted the establishment and implementation of additional procedures and training for operations involving classified removable electronic media (CREM) storage. In addition, the definition of CREM has been expanded and the number of CREM has increased significantly. Procedures now require that all CREM be inventoried and accounted for on a weekly basis. Weekly inventories consist of a physical comparison of each item against the reportable inventory listing. Securing and accounting for CREM is a continuous challenge for existing security systems. To address this challenge, an innovative framework, encompassing a suite of technologies, has been developed by Pacific Northwest National Laboratory (PNNL) to monitor, track, and locate CREM in safes, vaults, and storage areas. This Automated Removable Media Observation and Reporting (ARMOR)framework, described in this paper, is an extension of an existing PNNL program, SecureSafe. The key attributes of systems built around the ARMOR framework include improved accountability, reduced risk of human error, improved accuracy and timeliness of inventory data, and reduced costs. ARMOR solutions require each CREM to be tagged with a unique electronically readable ID code. Inventory data is collected from tagged CREM at regular intervals and upon detection of an access event. Automated inventory collection and report generation eliminates the need for hand-written inventory sheets and allows electronic transfer of the collected inventory data to a modern electronic reporting system. An electronic log of CREM access events is maintained, providing enhanced accountability for daily/weekly checks, routine audits, and follow-up investigations.

  2. ASKME Enterprise Portal (internal) -

    Data.gov (United States)

    Department of Transportation — The ASKME Enterprise Portal Internal (AEPi) is envisioned to be an integrated, single-point-of-entry solution that contains modular components. The AEPi will provide...

  3. DAMT - DISTRIBUTED APPLICATION MONITOR TOOL (HP9000 VERSION)

    Science.gov (United States)

    Keith, B.

    1994-01-01

    Typical network monitors measure status of host computers and data traffic among hosts. A monitor to collect statistics about individual processes must be unobtrusive and possess the ability to locate and monitor processes, locate and monitor circuits between processes, and report traffic back to the user through a single application program interface (API). DAMT, Distributed Application Monitor Tool, is a distributed application program that will collect network statistics and make them available to the user. This distributed application has one component (i.e., process) on each host the user wishes to monitor as well as a set of components at a centralized location. DAMT provides the first known implementation of a network monitor at the application layer of abstraction. Potential users only need to know the process names of the distributed application they wish to monitor. The tool locates the processes and the circuit between them, and reports any traffic between them at a user-defined rate. The tool operates without the cooperation of the processes it monitors. Application processes require no changes to be monitored by this tool. Neither does DAMT require the UNIX kernel to be recompiled. The tool obtains process and circuit information by accessing the operating system's existing process database. This database contains all information available about currently executing processes. Expanding the information monitored by the tool can be done by utilizing more information from the process database. Traffic on a circuit between processes is monitored by a low-level LAN analyzer that has access to the raw network data. The tool also provides features such as dynamic event reporting and virtual path routing. A reusable object approach was used in the design of DAMT. The tool has four main components; the Virtual Path Switcher, the Central Monitor Complex, the Remote Monitor, and the LAN Analyzer. All of DAMT's components are independent, asynchronously executing

  4. LHCb : The DIRAC Web Portal 2.0

    CERN Multimedia

    Mathe, Zoltan; Lazovsky, N; Stagni, Federico

    2015-01-01

    For many years the DIRAC interware (Distributed Infrastructure with Remote Agent Control) has had a web interface, allowing the users to monitor DIRAC activities and also interact with the system. Since then many new web technologies have emerged, therefore a redesign and a new implementation of the DIRAC Web portal were necessary, taking into account the lessons learnt using the old portal. These new technologies allowed to build a more compact and more responsive web interface that is robust and that enables users to have more control over the whole system while keeping a simple interface. The framework provides a large set of "applications", each of which can be used for interacting with various parts of the system. Communities can also create their own set of personalised web applications, and can easily extend already existing web applications with a minimal effort. Each user can configure and personalise the view for each application and save it using the DIRAC User Profile service as RESTful state prov...

  5. Initiating Events Modeling for On-Line Risk Monitoring Application

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.

    1998-01-01

    In order to make on-line risk monitoring application of Probabilistic Risk Assessment more complete and realistic, a special attention need to be dedicated to initiating events modeling. Two different issues are of special importance: one is how to model initiating events frequency according to current plant configuration (equipment alignment and out of service status) and operating condition (weather and various activities), and the second is how to preserve dependencies between initiating events model and rest of PRA model. First, the paper will discuss how initiating events can be treated in on-line risk monitoring application. Second, practical example of initiating events modeling in EPRI's Equipment Out of Service on-line monitoring tool will be presented. Gains from application and possible improvements will be discussed in conclusion. (author)

  6. APPLICATION OF SMART MOBILE PHONES IN VIBRATION MONITORING

    Directory of Open Access Journals (Sweden)

    Ljubomir Vračar

    2015-08-01

    Full Text Available The purpose of the research presented in this paper is the development of the smart mobile phone application for vibration monitoring of pumping aggregate, based on Microchip’s microcontroller (MC. Hardware used is based on Bluetooth connection between smart sensor and smart mobile phone. Software for acquisition and data analysis is optimized for imbedded application in smart sensors. Smart acceleration sensor in conjunction with Bluetooth connection to smart mobile phone creates one touch mobile vibration monitoring system. The authors have performed numerous measurements on a wide range of aggregates for establishing the operating functionality of the newly created system. The possibility of system application I rail vehicle vibration monitoring is also analyzed.

  7. Vibration-based condition monitoring industrial, aerospace and automotive applications

    CERN Document Server

    Randall, Robert Bond

    2010-01-01

    ""Without doubt the best modern and up-to-date text on the topic, wirtten by one of the world leading experts in the field. Should be on the desk of any practitioner or researcher involved in the field of Machine Condition Monitoring"" Simon Braun, Israel Institute of Technology Explaining complex ideas in an easy to understand way, Vibration-based Condition Monitoring provides a comprehensive survey of the application of vibration analysis to the condition monitoring of machines. Reflecting the natural progression of these systems by presenting the fundamental material

  8. Liferay Portal Systems Development

    CERN Document Server

    Yuan, Jonas X

    2012-01-01

    This book focuses on teaching by example. Every chapter provides an overview, and then dives right into hands-on examples so you can see and play with the solution in your own environment. This book is for Java developers who don't need any prior experience with Liferay portal. Although Liferay portal makes heavy use of open source frameworks, no prior experience of using these is assumed.

  9. ELECTRONIC COMMERCE PORTAL

    OpenAIRE

    Georgeta Soava

    2011-01-01

    Today companies are faced with the need to exploit technology changing computer environments, in order to improve customer satisfaction and reduce costs. A successful approach to electronic portals is an effective demonstration of the new ways of relating to the client. The objectives that we have considered for the realization of e-commerce portal can be summarized as follows: structured communication, effective collaboration, complet and closed circuit of orders and deliveries, inventory op...

  10. Open Source Platform Application to Groundwater Characterization and Monitoring

    Science.gov (United States)

    Ntarlagiannis, D.; Day-Lewis, F. D.; Falzone, S.; Lane, J. W., Jr.; Slater, L. D.; Robinson, J.; Hammett, S.

    2017-12-01

    Groundwater characterization and monitoring commonly rely on the use of multiple point sensors and human labor. Due to the number of sensors, labor, and other resources needed, establishing and maintaining an adequate groundwater monitoring network can be both labor intensive and expensive. To improve and optimize the monitoring network design, open source software and hardware components could potentially provide the platform to control robust and efficient sensors thereby reducing costs and labor. This work presents early attempts to create a groundwater monitoring system incorporating open-source software and hardware that will control the remote operation of multiple sensors along with data management and file transfer functions. The system is built around a Raspberry PI 3, that controls multiple sensors in order to perform on-demand, continuous or `smart decision' measurements while providing flexibility to incorporate additional sensors to meet the demands of different projects. The current objective of our technology is to monitor exchange of ionic tracers between mobile and immobile porosity using a combination of fluid and bulk electrical-conductivity measurements. To meet this objective, our configuration uses four sensors (pH, specific conductance, pressure, temperature) that can monitor the fluid electrical properties of interest and guide the bulk electrical measurement. This system highlights the potential of using open source software and hardware components for earth sciences applications. The versatility of the system makes it ideal for use in a large number of applications, and the low cost allows for high resolution (spatially and temporally) monitoring.

  11. Image acquisition system for traffic monitoring applications

    Science.gov (United States)

    Auty, Glen; Corke, Peter I.; Dunn, Paul; Jensen, Murray; Macintyre, Ian B.; Mills, Dennis C.; Nguyen, Hao; Simons, Ben

    1995-03-01

    An imaging system for monitoring traffic on multilane highways is discussed. The system, named Safe-T-Cam, is capable of operating 24 hours per day in all but extreme weather conditions and can capture still images of vehicles traveling up to 160 km/hr. Systems operating at different remote locations are networked to allow transmission of images and data to a control center. A remote site facility comprises a vehicle detection and classification module (VCDM), an image acquisition module (IAM) and a license plate recognition module (LPRM). The remote site is connected to the central site by an ISDN communications network. The remote site system is discussed in this paper. The VCDM consists of a video camera, a specialized exposure control unit to maintain consistent image characteristics, and a 'real-time' image processing system that processes 50 images per second. The VCDM can detect and classify vehicles (e.g. cars from trucks). The vehicle class is used to determine what data should be recorded. The VCDM uses a vehicle tracking technique to allow optimum triggering of the high resolution camera of the IAM. The IAM camera combines the features necessary to operate consistently in the harsh environment encountered when imaging a vehicle 'head-on' in both day and night conditions. The image clarity obtained is ideally suited for automatic location and recognition of the vehicle license plate. This paper discusses the camera geometry, sensor characteristics and the image processing methods which permit consistent vehicle segmentation from a cluttered background allowing object oriented pattern recognition to be used for vehicle classification. The image capture of high resolution images and the image characteristics required for the LPRMs automatic reading of vehicle license plates, is also discussed. The results of field tests presented demonstrate that the vision based Safe-T-Cam system, currently installed on open highways, is capable of producing automatic

  12. Biology of portal hypertension.

    Science.gov (United States)

    McConnell, Matthew; Iwakiri, Yasuko

    2018-02-01

    Portal hypertension develops as a result of increased intrahepatic vascular resistance often caused by chronic liver disease that leads to structural distortion by fibrosis, microvascular thrombosis, dysfunction of liver sinusoidal endothelial cells (LSECs), and hepatic stellate cell (HSC) activation. While the basic mechanisms of LSEC and HSC dysregulation have been extensively studied, the role of microvascular thrombosis and platelet function in the pathogenesis of portal hypertension remains to be clearly characterized. As a secondary event, portal hypertension results in splanchnic and systemic arterial vasodilation, leading to the development of a hyperdynamic circulatory syndrome and subsequently to clinically devastating complications including gastroesophageal varices and variceal hemorrhage, hepatic encephalopathy from the formation of portosystemic shunts, ascites, and renal failure due to the hepatorenal syndrome. This review article discusses: (1) mechanisms of sinusoidal portal hypertension, focusing on HSC and LSEC biology, pathological angiogenesis, and the role of microvascular thrombosis and platelets, (2) the mesenteric vasculature in portal hypertension, and (3) future directions for vascular biology research in portal hypertension.

  13. Outsourcing the Portal: Another Branch in the Decision Tree.

    Science.gov (United States)

    McMahon, Tim

    2000-01-01

    Discussion of the management of information resources in organizations focuses on the use of portal technologies to update intranet capabilities. Considers application outsourcing decisions, reviews benefits (including reducing costs) as well as concerns, and describes application service providers (ASPs). (LRW)

  14. Applications of fiber optic sensors in concrete structural health monitoring

    Science.gov (United States)

    Dai, Jingyun; Zhang, Wentao; Sun, Baochen; Du, Yanliang

    2007-11-01

    The research of fiber optic extrinsic Fabry-Perot interferometer (EFPI) sensors and their applications in concrete structural health monitoring are presented in this paper. Different types of fiber optic EFPI sensors are designed and fabricated. Experiments are carried out to test the performance of the sensors. The results show that the sensors have good linearity and stability. The applications of the fiber optic EFPI sensors in concrete structural health monitoring are also introduced. Ten fiber optic sensors are embedded into one section of the Liaohe Bridge in Qinghuangdao-Shenyang Railway. Field test demonstrates that the results of fiber optic sensors agree well with conventional strain gauges.

  15. ERNIE performance with TSA portals Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Labov, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2018-01-05

    This project extends the “Enhanced Radiological Nuclear Inspection and Evaluation” (ERNIE) system developed with CBP and DNDO to improve performance of PVT-based Radiation Portal Monitors (RPMs). ERNIE was designed to be used with any RPM system. The first implementation was with the SAIC (Leidos) RPM-8 systems. In this project, we are demonstrating how effective the ERNIE approach can be when applied to the VM250 TSA portals used in NSDD programs. Part of the challenge in adapting ERNIE to handle VM250 portals is the lack of gamma spectral information. We report here on the first results showing how the ERNIE analysis can improve analysis of measurements with the VM250 RPMs.

  16. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    Lattin, Kenneth R.

    1978-01-01

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  17. GIS Application System Design Applied to Information Monitoring

    Science.gov (United States)

    Qun, Zhou; Yujin, Yuan; Yuena, Kang

    Natural environment information management system involves on-line instrument monitoring, data communications, database establishment, information management software development and so on. Its core lies in collecting effective and reliable environmental information, increasing utilization rate and sharing degree of environment information by advanced information technology, and maximizingly providing timely and scientific foundation for environmental monitoring and management. This thesis adopts C# plug-in application development and uses a set of complete embedded GIS component libraries and tools libraries provided by GIS Engine to finish the core of plug-in GIS application framework, namely, the design and implementation of framework host program and each functional plug-in, as well as the design and implementation of plug-in GIS application framework platform. This thesis adopts the advantages of development technique of dynamic plug-in loading configuration, quickly establishes GIS application by visualized component collaborative modeling and realizes GIS application integration. The developed platform is applicable to any application integration related to GIS application (ESRI platform) and can be as basis development platform of GIS application development.

  18. Condition Monitoring Of Operating Pipelines With Operational Modal Analysis Application

    Directory of Open Access Journals (Sweden)

    Mironov Aleksey

    2015-12-01

    Full Text Available In the petroleum, natural gas and petrochemical industries, great attention is being paid to safety, reliability and maintainability of equipment. There are a number of technologies to monitor, control, and maintain gas, oil, water, and sewer pipelines. The paper focuses on operational modal analysis (OMA application for condition monitoring of operating pipelines. Special focus is on the topicality of OMA for definition of the dynamic features of the pipeline (frequencies and mode shapes in operation. The research was conducted using two operating laboratory models imitated a part of the operating pipeline. The results of finite-element modeling, identification of pipe natural modes and its modification under the influence of virtual failure are discussed. The work considers the results of experimental research of dynamic behavior of the operating pipe models using one of OMA techniques and comparing dynamic properties with the modeled data. The study results demonstrate sensitivity of modal shape parameters to modification of operating pipeline technical state. Two strategies of pipeline repair – with continuously condition-based monitoring with proposed technology and without such monitoring, was discussed. Markov chain reliability models for each strategy were analyzed and reliability improvement factor for proposed technology of monitoring in compare with traditional one was evaluated. It is resumed about ability of operating pipeline condition monitoring by measuring dynamic deformations of the operating pipe and OMA techniques application for dynamic properties extraction.

  19. Application of online chemistry monitoring programs and technology

    International Nuclear Information System (INIS)

    Perkins, D.; Choi, S.; Haas, C.

    2010-01-01

    To fully understand the impact of chemistry changes, several plant parameters must be considered and reviewed with actual chemistry analyses and compared to plant operating parameters. In some cases, this requires the ability to rapidly correlate plant operational data with laboratory and chemistry data. An effective online monitoring system should be able to: Integrate and extract online data from the plant laboratory and operating information from various plant data sources continuously; Interrogate and extract laboratory data from manually entered data on predefined frequencies; Interact with multiple laboratories in multiple locations; Evaluate data against plant limits (calculated or static) and provide personnel with action level or notification of plant exceeding limits; and, Provide the ability to evaluate against a standard and site specific set of calculations. The nuclear power industry continues to refine and apply new technologies in an effort to notify operators of changes in chemical conditions, calculate complex high temperature results, and monitor system performance. EPRI developed software specifically focused on plant chemistry program optimization using power operation and shutdown data applied with plant equipment. This software evolved into the family of software referred to as EPRI ChemWorks™ applications. As technology changed and improved, the application of online monitoring was essential for plant personnel working offsite. These changes in technology prompted EPRI to the development of SMART ChemWorks™ using the EPRI ChemWorks™ plant chemistry simulator and MULTEQ applications as the backbone for these simulations and calculations. SMART ChemWorks™ is an online monitoring system that queries plant databases and continuously monitors plant and chemistry parameters. The system uses a real-time intelligence engine to perform virtual sensing, identify normal and off-normal conditions and compare in-line instrument output to grab

  20. Application of the ALARA principle to individual occupational radiation monitoring

    International Nuclear Information System (INIS)

    Aleinikov, V.E.

    1998-01-01

    Routine individual occupational radiation monitoring is necessary to ensure that exposure are kept as low as reasonably achievable (ALARA) and that the authorized dose limits are not exceeded. The type and extend of the monitoring depend on the nature and magnitude of occupational radiation exposure. Optimal choice of the wearing time for individual dosimeters, T, has important consequences for achievement of the individual monitoring objects. The choice of T depends on individual dose distribution, the lower detection limit for the detector used, the lost of an information during period of monitoring, the cost of the measurements and the benefits associated with the results. The paper describes the application of quantitative optimization techniques to optimize the wearing time for individual dosimeters. It was shown how optimal wearing time for individual dosimeters depends on dose distribution, the lower detection limit, dose limit, fading and cost of the measurements. (author)

  1. Environmental Monitoring Curriculum System and Application-Oriented Training

    Science.gov (United States)

    Wang, Jing-Ping; Wang, Xin-Hong

    2016-01-01

    Through building the environmental monitoring curriculum system for application-oriented talents, the comprehensive design and practice were constructed from the syllabus, textbooks, web-based courses, top-quality courses, test paper bank, open laboratory and scientific research etc. The aims are to promote environmental science professional,…

  2. Extrahepatic portal hypertension in childhood

    International Nuclear Information System (INIS)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-01-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood. (author)

  3. Advances in the treatment of portal hypertension in cirrhosis.

    Science.gov (United States)

    Kimer, N; Wiese, S; Mo, S; Møller, S; Bendtsen, F

    2016-08-01

    Non-selective beta-blockers and handling of esophageal varices has been key elements in the treatment of portal hypertension in recent decades. Liver vein catheterization has been essential in diagnosis and monitoring of portal hypertension, but ongoing needs for noninvasive tools has led to research in areas of both biomarkers, and transient elastography, which displays promising results in discerning clinically significant portal hypertension. Novel research into the areas of hepatic stellate cell function and the dynamic components of portal hypertension has revealed promising areas of treatment modalities, targeting intestinal decontamination, angiogenesis, inflammation and oxidative stress. Future studies may reveal if these initiatives lead to developments of new drugs for treatment of portal hypertension.

  4. Advances in the treatment of portal hypertension in cirrhosis

    DEFF Research Database (Denmark)

    Kimer, Nina; Wiese, S; Mo, S S

    2016-01-01

    Non-selective beta-blockers and handling of esophageal varices has been key elements in the treatment of portal hypertension in recent decades. Liver vein catheterization has been essential in diagnosis and monitoring of portal hypertension, but ongoing needs for noninvasive tools has led...... to research in areas of both biomarkers, and transient elastography, which displays promising results in discerning clinically significant portal hypertension. Novel research into the areas of hepatic stellate cell function and the dynamic components of portal hypertension has revealed promising areas...... of treatment modalities, targeting intestinal decontamination, angiogenesis, inflammation and oxidative stress. Future studies may reveal if these initiatives lead to developments of new drugs for treatment of portal hypertension....

  5. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis.

    Science.gov (United States)

    Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo

    2005-06-07

    To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

  6. Pregnancy with Portal Hypertension

    Science.gov (United States)

    Aggarwal, Neelam; Negi, Neha; Aggarwal, Aakash; Bodh, Vijay; Dhiman, Radha K.

    2014-01-01

    Even though pregnancy is rare with cirrhosis and advanced liver disease, but it may co-exist in the setting of non-cirrhotic portal hypertension as liver function is preserved but whenever encountered together is a complex clinical dilemma. Pregnancy in a patient with portal hypertension presents a special challenge to the obstetrician as so-called physiological hemodynamic changes associated with pregnancy, needed for meeting demands of the growing fetus, worsen the portal hypertension thereby putting mother at risk of potentially life-threatening complications like variceal hemorrhage. Risks of variceal bleed and hepatic decompensation increase many fold during pregnancy. Optimal management revolves round managing the portal hypertension and its complications. Thus management of such cases requires multi-speciality approach involving obstetricians experienced in dealing with high risk cases, hepatologists, anesthetists and neonatologists. With advancement in medical field, pregnancy is not contra-indicated in these women, as was previously believed. This article focuses on the different aspects of pregnancy with portal hypertension with special emphasis on specific cause wise treatment options to decrease the variceal bleed and hepatic decompensation. Based on extensive review of literature, management from pre-conceptional period to postpartum is outlined in order to have optimal maternal and perinatal outcomes. PMID:25755552

  7. Radioisotopic flow scanning for portal blood flow and portal hypertension

    International Nuclear Information System (INIS)

    Hesdorffer, C.S.; Bezwoda, W.R.; Danilewitz, M.D.; Esser, J.D.; Tobias, M.

    1987-01-01

    The use of a simple, noninvasive, isotope scanning technique for the determination of relative portal blood flow and detection of portal hypertension is described. Using this technique the presence of portal hypertension was demonstrated in seven of nine patients known to have elevated portal venous pressure. By contrast, esophageal varices were demonstrated in only five of these patients, illustrating the potential value of the method. Furthermore, this technique has been adapted to the study of portal blood flow in patients with myeloproliferative disorders with splenomegaly but without disturbances in hepatic architecture. Results demonstrate that the high relative splenic flow resulting from the presence of splenomegaly may in turn be associated with elevated relative portal blood flow and portal hypertension. The theoretic reasons for the development of flow-related portal hypertension and its relationship to splenic blood flow are discussed

  8. Web application for monitoring mainframe computer, Linux operating systems and application servers

    OpenAIRE

    Dimnik, Tomaž

    2016-01-01

    This work presents the idea and the realization of web application for monitoring the operation of the mainframe computer, servers with Linux operating system and application servers. Web application is intended for administrators of these systems, as an aid to better understand the current state, load and operation of the individual components of the server systems.

  9. Entropy Applications to Water Monitoring Network Design: A Review

    Directory of Open Access Journals (Sweden)

    Jongho Keum

    2017-11-01

    Full Text Available Having reliable water monitoring networks is an essential component of water resources and environmental management. A standardized process for the design of water monitoring networks does not exist with the exception of the World Meteorological Organization (WMO general guidelines about the minimum network density. While one of the major challenges in the design of optimal hydrometric networks has been establishing design objectives, information theory has been successfully adopted to network design problems by providing measures of the information content that can be deliverable from a station or a network. This review firstly summarizes the common entropy terms that have been used in water monitoring network designs. Then, this paper deals with the recent applications of the entropy concept for water monitoring network designs, which are categorized into (1 precipitation; (2 streamflow and water level; (3 water quality; and (4 soil moisture and groundwater networks. The integrated design method for multivariate monitoring networks is also covered. Despite several issues, entropy theory has been well suited to water monitoring network design. However, further work is still required to provide design standards and guidelines for operational use.

  10. Application of monitoring and targeting to energy management

    Energy Technology Data Exchange (ETDEWEB)

    Gotel, D G; Hale, D K

    1989-01-01

    This general guide has been prepared to show how monitoring and targeting can control energy use and improve the efficiency with which energy is used in different sectors of the national economy. It is based on the results of work carried out, under the Energy Efficiency Office Monitoring and Targeting Programme, on the development of practical energy management systems for use in manufacturing industry, commerce and the public sector. The principles of monitoring and targeting are described together with the steps which have to be taken to set up monitoring and targeting as an integral part of an existing management organization. Procedures are given for monitoring energy use, defining standards and targets, reporting results and reviewing progress. These procedures which have been developed and tested in working environments are illustrated with examples of their practical application. Finally, an account is given of the improvements of performance in the use of energy and the other benefits which can be gained through energy monitoring and targeting.

  11. Advanced Machine learning Algorithm Application for Rotating Machine Health Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kanemoto, Shigeru; Watanabe, Masaya [The University of Aizu, Aizuwakamatsu (Japan); Yusa, Noritaka [Tohoku University, Sendai (Japan)

    2014-08-15

    The present paper tries to evaluate the applicability of conventional sound analysis techniques and modern machine learning algorithms to rotating machine health monitoring. These techniques include support vector machine, deep leaning neural network, etc. The inner ring defect and misalignment anomaly sound data measured by a rotating machine mockup test facility are used to verify the above various kinds of algorithms. Although we cannot find remarkable difference of anomaly discrimination performance, some methods give us the very interesting eigen patterns corresponding to normal and abnormal states. These results will be useful for future more sensitive and robust anomaly monitoring technology.

  12. Applications of moisture monitoring using TAUPE-sensors

    International Nuclear Information System (INIS)

    Koeniger, F.

    2007-01-01

    TAUPE as a moisture sensor has been developed in cooperation with Technology Transfer Division in Forschungszentrum Karlsruhe since 1996. These sensors can be used to monitor moisture in a variety of materials, using time domain or frequency domain techniques. Major applications are large area supervision of landfill sealings, determination of the snow water equivalent, e.g. in the project SNOWPOWER for the forecasting of the amount of water for energy production in storage lakes and, as a new project, continuous monitoring of groundwater level in the flood plane of river Rhine. (orig.)

  13. Advanced Machine learning Algorithm Application for Rotating Machine Health Monitoring

    International Nuclear Information System (INIS)

    Kanemoto, Shigeru; Watanabe, Masaya; Yusa, Noritaka

    2014-01-01

    The present paper tries to evaluate the applicability of conventional sound analysis techniques and modern machine learning algorithms to rotating machine health monitoring. These techniques include support vector machine, deep leaning neural network, etc. The inner ring defect and misalignment anomaly sound data measured by a rotating machine mockup test facility are used to verify the above various kinds of algorithms. Although we cannot find remarkable difference of anomaly discrimination performance, some methods give us the very interesting eigen patterns corresponding to normal and abnormal states. These results will be useful for future more sensitive and robust anomaly monitoring technology

  14. Measuring Problem Solving Skills in "Portal 2"

    Science.gov (United States)

    Shute, Valerie J.; Wang, Lubin

    2013-01-01

    This paper examines possible improvement to problem solving skills as a function of playing the video game "Portal 2." Stealth assessment is used in the game to evaluate students' problem solving abilities--specifically basic and flexible rule application. The stealth assessment measures will be validated against commonly accepted…

  15. Portal Environment in Today’s Business

    OpenAIRE

    Aldubaikhi, Ammar

    2015-01-01

    Companies can get benefits from new business models as they can have better and efficient collaboration system and this can be derived from the discussed application in this paper. Companies that easily personalize the SAP enterprise portal are more productive and this reflects their interests in business

  16. Awareness and Use of the After-Visit Summary Through a Patient Portal: Evaluation of Patient Characteristics and an Application of the Theory of Planned Behavior.

    Science.gov (United States)

    Emani, Srinivas; Healey, Michael; Ting, David Y; Lipsitz, Stuart R; Ramelson, Harley; Suric, Vladimir; Bates, David W

    2016-04-13

    Patient portals are being used to provide a clinical summary of the office visit or the after-visit summary (AVS) to patients. There has been relatively little research on the characteristics of patients who access the AVS through a patient portal and their beliefs about the AVS. The aim was to (1) assess the characteristics of patients who are aware of and access the AVS through a patient portal and (2) apply the Theory of Planned Behavior (TPB) to predict behavioral intention of patients toward accessing the AVS provided through a patient portal. We developed a survey capturing the components of TPB (beliefs, attitude, perceived norm, and perceived behavioral control). Over a 6-month period, patients with a patient portal account with an office visit in the previous week were identified using our organization's scheduling system. These patients were sent an email about the study and a link to the survey via their portal account. We applied univariate statistical analysis (Pearson chi-square and 1-way ANOVA) to assess differences among groups (aware/unaware of AVS and accessed/did not access AVS). We reported means and standard deviations to depict belief strengths and presented correlations between beliefs and attitude, perceived norm, and perceived behavioral control. We used hierarchical regression analysis to predict behavioral intention toward accessing the AVS through the patient portal. Of the 23,336 patients who were sent the survey, 5370 responded for a response rate of 23.01%. Overall, 76.52% (4109/5370) were aware that the AVS was available through the patient portal and 54.71% of those (2248/4109) accessed the AVS within 5 days of the office visit. Patients who accessed the AVS had a greater number of sessions with the portal (mean 119, SD 221.5) than those who did not access the AVS (mean 79.1, SD 123.3, PAVS. The strongest behavioral beliefs with accessing the AVS were being able to track visits and tests (mean 2.53, SD 1.00) followed by having

  17. Personalization Methods for Internet Portals

    OpenAIRE

    Barbara Dębska; Agnieszka Kubacka

    2012-01-01

    The article presents methods of acquiring and gathering data about users of internet portals, with particular emphasis on educational portals. Definitions, aims and tasks related to the process of personalization of e-learning portals are thoroughly discussed. So are knowledge acquisition techniques applied in personalization, especially artificial intelligence methods.

  18. Per-rectal portal scintigraphy in chronic liver diseases

    International Nuclear Information System (INIS)

    Frusciante, V.; Barbano, F.; Btuno, M.; Facciorusso, D.; Tonti, P.; Giacobbe, A.; Andriulli, A.; Vettori, P.G.P.

    1993-01-01

    Portal circulation has been evaluated by per-rectal portal scintigraphy in 21 controls and in 30 pts affected by chronic liver diseases. Tc99m-pertechnetate (10 mci) was given through a Nelaton's catheter in the upper rectum; a per-rectal portal shunt index (SI) was calculated. A relevant overlap is evident between controls and CHP pts; no overlap exists between controls and B or C graded cirrhosis. We conclude that the technique may be suggested to monitor the course of chronic liver diseases and different therapeutic regimens. (orig.) [de

  19. Assessment of the Manufacturing Possibility of Thin-Walled Robotic Portals for Conveyor Worklace

    Directory of Open Access Journals (Sweden)

    Peter Michalik

    2018-03-01

    Full Text Available The paper discusses evaluation of machining solutions for oversized thin-walled robotic portal component for conveyance workplaces. The following portal CNC machining centers have been selected. Firstly, a FSGC 300 “portal type” portal was proposed, with a 50000 mm “X” axis and Heidenhain control system, the second portal was a DMU 340 portal with the maximum axis “X” of 6000 mm and Siemens Sinumerik control system and the last portal was the VF-10 / 40 one, with the maximum axis “X” of 3048 mm and Fanuc control system. Further, the method of fixing a thin-walled robotic portal is designed and individual options are evaluated for their economy. The CAM software application used for programming the production was SolidWorks.

  20. PPP Sliding Window Algorithm and Its Application in Deformation Monitoring

    Science.gov (United States)

    Song, Weiwei; Zhang, Rui; Yao, Yibin; Liu, Yanyan; Hu, Yuming

    2016-01-01

    Compared with the double-difference relative positioning method, the precise point positioning (PPP) algorithm can avoid the selection of a static reference station and directly measure the three-dimensional position changes at the observation site and exhibit superiority in a variety of deformation monitoring applications. However, because of the influence of various observing errors, the accuracy of PPP is generally at the cm-dm level, which cannot meet the requirements needed for high precision deformation monitoring. For most of the monitoring applications, the observation stations maintain stationary, which can be provided as a priori constraint information. In this paper, a new PPP algorithm based on a sliding window was proposed to improve the positioning accuracy. Firstly, data from IGS tracking station was processed using both traditional and new PPP algorithm; the results showed that the new algorithm can effectively improve positioning accuracy, especially for the elevation direction. Then, an earthquake simulation platform was used to simulate an earthquake event; the results illustrated that the new algorithm can effectively detect the vibrations change of a reference station during an earthquake. At last, the observed Wenchuan earthquake experimental results showed that the new algorithm was feasible to monitor the real earthquakes and provide early-warning alerts. PMID:27241172

  1. ContextProvider: Context awareness for medical monitoring applications.

    Science.gov (United States)

    Mitchell, Michael; Meyers, Christopher; Wang, An-I Andy; Tyson, Gary

    2011-01-01

    Smartphones are sensor-rich and Internet-enabled. With their on-board sensors, web services, social media, and external biosensors, smartphones can provide contextual information about the device, user, and environment, thereby enabling the creation of rich, biologically driven applications. We introduce ContextProvider, a framework that offers a unified, query-able interface to contextual data on the device. Unlike other context-based frameworks, ContextProvider offers interactive user feedback, self-adaptive sensor polling, and minimal reliance on third-party infrastructure. ContextProvider also allows for rapid development of new context and bio-aware applications. Evaluation of ContextProvider shows the incorporation of an additional monitoring sensor into the framework with fewer than 100 lines of Java code. With adaptive sensor monitoring, power consumption per sensor can be reduced down to 1% overhead. Finally, through the use of context, accuracy of data interpretation can be improved by up to 80%.

  2. Wireless body sensor networks for health-monitoring applications

    International Nuclear Information System (INIS)

    Hao, Yang; Foster, Robert

    2008-01-01

    Current wireless technologies, such as wireless body area networks and wireless personal area networks, provide promising applications in medical monitoring systems to measure specified physiological data and also provide location-based information, if required. With the increasing sophistication of wearable and implantable medical devices and their integration with wireless sensors, an ever-expanding range of therapeutic and diagnostic applications is being pursued by research and commercial organizations. This paper aims to provide a comprehensive review of recent developments in wireless sensor technology for monitoring behaviour related to human physiological responses. It presents background information on the use of wireless technology and sensors to develop a wireless physiological measurement system. A generic miniature platform and other available technologies for wireless sensors have been studied in terms of hardware and software structural requirements for a low-cost, low-power, non-invasive and unobtrusive system. (topical review)

  3. The Learning Portal

    Science.gov (United States)

    Staudt, Carolyn; Hanzlick-Burton, Camden; Williamson, Carol; McIntyre, Cynthia

    2015-01-01

    The Innovative Technology in Science Inquiry (ITSI) project is a learning portal with hundreds of free, customizable science, math, and engineering activities funded by the National Science Foundation at the Concord Consortium, a nonprofit research and development organization dedicated to transforming education through technology. The project…

  4. Beacon-Colss core monitoring system application and benefits

    International Nuclear Information System (INIS)

    Boyd, W.A.; Yoon, T.Y.

    2005-01-01

    Westinghouse and KNFC are creating an upgraded core monitoring system by merging the BEACON system (best estimate analyzer for core operation-nuclear) and COLSS (core operating limit supervisory system) into an integrated product. Although both BEACON and COLSS are core monitoring systems that have been in operation at many plants for a number of years, they each have some features and capabilities that are not in the other. Therefore it has been decided to incorporate portions of COLSS into the beacon system to create an optional level to support core monitoring applications on selected combustion engineering (C-E) designed plants. This optional level in the beacon system will be called BEACON-COLSS and will allow the beacon system to monitor the LCO's and Tech Spec limits at CE plants that currently use COLSS. This paper will present the structure of the new core monitoring system and the benefits it achieves for current COLSS plants, i.e., CE plants in the US and KSNP (Korean standard nuclear power plant). (authors)

  5. Application of Equipment Monitoring Technology in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kang, H. T.; Lee, J. K.; Lee, K. D.; Jo, S. H.

    2012-01-01

    The major goal of nuclear power industries during the past 10 years is to increase reliability and utility capacity factor. As the capacitor factor, however, crept upward. it became harder to attain next percentage of improvement. Therefore other innovative technologies are required. By the technologies applied to the fossil power plants, equipment health monitoring was performed on equipment to maintain it in operable condition and contributed on improving their reliability a lot. But the equipment monitoring may be limited to the observation of current system states in nuclear power plant. Monitoring of current system states is being augmented with prediction of future operating states and predictive diagnosis of future failure states. Such predictive diagnosis is motivated by the need for nuclear power plants to optimize equipment performance and reduce costs and unscheduled downtime. This paper reviews the application of techniques that focus on improving reliability in nuclear power plant by monitoring and predicting equipment health and suggests how possible to support on-line monitoring

  6. Application of Risk Monitor MAREas tool in operation and maintenance

    International Nuclear Information System (INIS)

    Carretero, J. A.; Fuentes, I.

    2004-01-01

    From the very beginning and ongoing application objective of the Probabilistic Safety Assessment (PSA) was to develop Monitors. Their development was contingent on the PSA model computing capacity of the computer tools. the availability of effective tools, as well as the requirements of the Consejo de Seguridad Nuclear to apply the Maintenance Rule, have driven their implementation in Spain. The MARE application of Empresarios Agrupados presented herein has been developed for that purpose and has been implemented in Almaraz NPP. This article describes the process followed and experience in using it. (Author)

  7. Improving diabetes management with a patient portal: a qualitative study of diabetes self-management portal.

    Science.gov (United States)

    Urowitz, Sara; Wiljer, David; Dupak, Kourtney; Kuehner, Zachary; Leonard, Kevin; Lovrics, Emily; Picton, Peter; Seto, Emily; Cafazzo, Joe

    2012-11-30

    Effective management and care of diabetes is crucial to reducing associated risks such as heart disease and kidney failure. With increasing access and use of the Internet, online chronic disease management is being explored as a means of providing patients with support and the necessary tools to monitor and manage their disease. The objective of our study was to evaluate the experience of patients and providers using an online diabetes management portal for patients. Participants were recruited from a large sample population of 887 for a follow-up questionnaire to be completed after 6 months of using the patient portal. Participants were presented with the option to participate in an additional interview and, if the participant agreed, a time and date was scheduled for the interview. A 5-item, open-ended questionnaire was used to capture providers' opinions of the patient portal. Providers included general practitioners (GPs), nurses, nurse practitioners (NPs), dieticians, diabetes educators (DECs), and other clinical staff. A total of 854 patients were consented for the questionnaire. Seventeen (8 male, 9 female) patients agreed to participate in a telephone interview. Sixty-four health care providers completed the five open-ended questions; however, an average of 48.2 responses were recorded per question. Four major themes were identified and will be discussed in this paper. These themes have been classified as: facilitators of disease management, barriers to portal use, patient-provider communication and relationship, and recommendations for portal improvements. This qualitative study shows that online chronic disease management portals increase patient access to information and engagement in their health care, but improvements in the portal itself may improve usability and reduce attrition. Furthermore, this study identifies a grey area that exists in the roles that GPs and AHPs should play in the facilitation of online disease management.

  8. [Evaluation and treatment of portal hypertension].

    Science.gov (United States)

    Brůha, Radan; Petrtýl, Jaromír

    Liver cirrhosis is a serious disease shortening the life expectancy. Unavoidable consequence of cirrhosis is portal hypertension, which usually limits the prognosis by its complications. Portal hypertension is a prognostic factor for cirrhosis decompensation, variceal bleeding and even the mortality in cirrhotic patients. In the evaluation of portal hypertension hepatic venous pressure gradient (HVPG) measurement is used.Measurement of HVPG is used in clinical praxis in these situations: diagnosis of portal hypertension, evaluation of prognosis of patients with cirrhosis, monitoring the treatment efficacy in the prevention of variceal bleeding, management of acute variceal bleeding. Decrease of HVPG below 12 mmHg or at least for more than 20% of initial value in the treatment by beta-blockers is associated with the lower risk of bleeding from varices or other complications. HVPG above 20 mm Hg is associated with the high risk of early rebleeding from varices and can discriminate those patients profiting from early TIPS.HVPG measurement is an invasive, but simple, reproducible and safe catheterization technique with minimal complication rate. The most frequent complication could be incorrect assessment of obtained values. HVPG measurement should be a routine technique in centers specialized to liver diseases.

  9. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    Purpose/Objective: The purpose of this presentation is to review the physics of imaging with high energy x-ray beams; examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine errors in patient positioning quantitatively; and discuss some of the ways that portal imaging has been incorporated into routine clinical practice. Verification of patient positioning has always been an important aspect of external beam radiation therapy. Checks of patient positioning have generally been done with film, however, film suffers from a number of drawbacks, such as poor image display and delays due to film development. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems, which are intended to overcome the limitations of portal films. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The fundamental factors which limit image quality and the characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same

  10. Development and applications of energy-specific fluence monitor for field monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Krishnakumar, D.N., E-mail: nkkumar@igcar.gov.i [Radiological Safety Division, Radiological Safety and Environmental Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, Tamilnadu (India); Somayaji, K.M.; Venkatesan, R.; Meenakshisundaram, V. [Radiological Safety Division, Radiological Safety and Environmental Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, Tamilnadu (India)

    2011-07-15

    A portable energy-specific fluence monitor is developed for field monitoring as well as to serve as stand-alone data acquisition system to measure dose rate due to routine releases at various locations in and around Nuclear Power Reactors. The data from an array of such monitors deployed over a region of interest would help in evolving a methodology to arrive at the source term evaluation in the event of a postulated nuclear incident. The other method that exists for this purpose is by conducting tracer experiments using known release of a gas like SF{sub 6} into the atmosphere and monitoring their concentrations downwind. The above instrument enables one to use the routine release of {sup 41}Ar as a tracer gas. The Argon fluence monitor houses a CsI(Tl) detector and associated miniature electronics modules for conditioning the signal from the detector. Data logging and in-situ archival of the data are controlled by a powerful web enabled communication controller preloaded with Microsoft Windows Compact Edition (WIN CE). The application software is developed in Visual Basic.NET under Compact Framework and deployed in the module. The paper gives an outline of the design aspects of the instrument, associated electronics and calibration of the instrument, including the preliminary results obtained using the instrument. The utility of the system is established by carrying out field survey around Madras Atomic Power Station (MAPS), consisting of two Pressurized Heavy Water Reactors (PHWR), by mapping the {sup 41}Ar plume. Additional features such as enhancing the monitor capability with embedded GPS along with real-time linking using wireless networking techniques are also being incorporated.

  11. A cloud-based information repository for bridge monitoring applications

    Science.gov (United States)

    Jeong, Seongwoon; Zhang, Yilan; Hou, Rui; Lynch, Jerome P.; Sohn, Hoon; Law, Kincho H.

    2016-04-01

    This paper describes an information repository to support bridge monitoring applications on a cloud computing platform. Bridge monitoring, with instrumentation of sensors in particular, collects significant amount of data. In addition to sensor data, a wide variety of information such as bridge geometry, analysis model and sensor description need to be stored. Data management plays an important role to facilitate data utilization and data sharing. While bridge information modeling (BrIM) technologies and standards have been proposed and they provide a means to enable integration and facilitate interoperability, current BrIM standards support mostly the information about bridge geometry. In this study, we extend the BrIM schema to include analysis models and sensor information. Specifically, using the OpenBrIM standards as the base, we draw on CSI Bridge, a commercial software widely used for bridge analysis and design, and SensorML, a standard schema for sensor definition, to define the data entities necessary for bridge monitoring applications. NoSQL database systems are employed for data repository. Cloud service infrastructure is deployed to enhance scalability, flexibility and accessibility of the data management system. The data model and systems are tested using the bridge model and the sensor data collected at the Telegraph Road Bridge, Monroe, Michigan.

  12. Smart sensor systems for human health breath monitoring applications.

    Science.gov (United States)

    Hunter, G W; Xu, J C; Biaggi-Labiosa, A M; Laskowski, D; Dutta, P K; Mondal, S P; Ward, B J; Makel, D B; Liu, C C; Chang, C W; Dweik, R A

    2011-09-01

    Breath analysis techniques offer a potential revolution in health care diagnostics, especially if these techniques can be brought into standard use in the clinic and at home. The advent of microsensors combined with smart sensor system technology enables a new generation of sensor systems with significantly enhanced capabilities and minimal size, weight and power consumption. This paper discusses the microsensor/smart sensor system approach and provides a summary of efforts to migrate this technology into human health breath monitoring applications. First, the basic capability of this approach to measure exhaled breath associated with exercise physiology is demonstrated. Building from this foundation, the development of a system for a portable asthma home health care system is described. A solid-state nitric oxide (NO) sensor for asthma monitoring has been identified, and efforts are underway to miniaturize this NO sensor technology and integrate it into a smart sensor system. It is concluded that base platform microsensor technology combined with smart sensor systems can address the needs of a range of breath monitoring applications and enable new capabilities for healthcare.

  13. Application of GNSS Methods for Monitoring Offshore Platform Deformation

    Science.gov (United States)

    Myint, Khin Cho; Nasir Matori, Abd; Gohari, Adel

    2018-03-01

    Global Navigation Satellite System (GNSS) has become a powerful tool for high-precision deformation monitoring application. Monitoring of deformation and subsidence of offshore platform due to factors such as shallow gas phenomena. GNSS is the technical interoperability and compatibility between various satellite navigation systems such as modernized GPS, Galileo, reconstructed GLONASS to be used by civilian users. It has been known that excessive deformation affects platform structurally, causing loss of production and affects the efficiency of the machinery on board the platform. GNSS have been proven to be one of the most precise positioning methods where by users can get accuracy to the nearest centimeter of a given position from carrier phase measurement processing of GPS signals. This research is aimed at using GNSS technique, which is one of the most standard methods to monitor the deformation of offshore platforms. Therefore, station modeling, which accounts for the spatial correlated errors, and hence speeds up the ambiguity resolution process is employed. It was found that GNSS combines the high accuracy of the results monitoring the offshore platforms deformation with the possibility of survey.

  14. Statistical application of groundwater monitoring data at the Hanford Site

    International Nuclear Information System (INIS)

    Chou, C.J.; Johnson, V.G.; Hodges, F.N.

    1993-09-01

    Effective use of groundwater monitoring data requires both statistical and geohydrologic interpretations. At the Hanford Site in south-central Washington state such interpretations are used for (1) detection monitoring, assessment monitoring, and/or corrective action at Resource Conservation and Recovery Act sites; (2) compliance testing for operational groundwater surveillance; (3) impact assessments at active liquid-waste disposal sites; and (4) cleanup decisions at Comprehensive Environmental Response Compensation and Liability Act sites. Statistical tests such as the Kolmogorov-Smirnov two-sample test are used to test the hypothesis that chemical concentrations from spatially distinct subsets or populations are identical within the uppermost unconfined aquifer. Experience at the Hanford Site in applying groundwater background data indicates that background must be considered as a statistical distribution of concentrations, rather than a single value or threshold. The use of a single numerical value as a background-based standard ignores important information and may result in excessive or unnecessary remediation. Appropriate statistical evaluation techniques include Wilcoxon rank sum test, Quantile test, ''hot spot'' comparisons, and Kolmogorov-Smirnov types of tests. Application of such tests is illustrated with several case studies derived from Hanford groundwater monitoring programs. To avoid possible misuse of such data, an understanding of the limitations is needed. In addition to statistical test procedures, geochemical, and hydrologic considerations are integral parts of the decision process. For this purpose a phased approach is recommended that proceeds from simple to the more complex, and from an overview to detailed analysis

  15. Best Practices for Building Web Data Portals

    Science.gov (United States)

    Anderson, R. A.; Drew, L.

    2013-12-01

    technology, SEO rich content and more. As a result, it was on the first page of numerous related Google search results within 24 hours of the portal launch. 8) Build in-browser data analysis tools showing scientists how the data can be used in their research. The ASF DAAC Wetlands portal demonstrates that allowing the user to examine the data quickly and graphically online readily enables users to perceive the value of the data and how to use it. 9) Use responsive Web design (RWD) so content and tools can be accessed from a wide range of devices. Wetlands and Seasat can be accessed from smartphones, tablets and desktops. 10) Use Web frameworks to enable rapid building of new portals using consistent design patterns. Seasat and Wetlands both use Django and Twitter Bootstrap. 11) Use load-balanced servers if high demand for the data is anticipated. Using load-balanced servers for the Seasat and Wetlands portals allows ASF to simply add hardware as needed to support increased capacity. 12) Use open-source software when possible. Seasat and Wetlands portal development costs were reduced, and functionality was increased, with the use of open-source software. 13) Use third-party virtual servers (e.g. Amazon EC2 and S3 Services) where applicable. 14) Track visitors using analytic tools. 15) Continually improve design.

  16. Designing the Search Service for Enterprise Portal based on Oracle Universal Content Management

    Science.gov (United States)

    Bauer, K. S.; Kuznetsov, D. Y.; Pominov, A. D.

    2017-01-01

    Enterprise Portal is an important part of an organization in informative and innovative space. The portal provides collaboration between employees and the organization. This article gives a valuable background of Enterprise Portal and technologies. The paper presents Oracle WebCenter Portal and UCM Server integration in detail. The focus is on tools for Enterprise Portal and on Search Service in particular. The paper also presents several UML diagrams to describe the use of cases for Search Service and main components of this application.

  17. Impact of hepatitis C oral therapy in portal hypertension.

    Science.gov (United States)

    Libânio, Diogo; Marinho, Rui Tato

    2017-07-14

    Chronic hepatitis C is a leading cause of morbidity and mortality, mainly related to fibrosis/cirrhosis and portal hypertension. Direct antiviral agents are highly effective and safe and can now cure > 90% of the patients. Sustained viral response (SVR) after interferon-based regimens has been associated with improvement in liver function, fibrosis and portal hypertension in a significant proportion of patients, although a point of no return seems to exist from which viral elimination is no longer capable of preventing portal hypertension progression and liver decompensation. Indeed, although SVR is associated with improvement of hepatic venous pressure gradients and therefore a decreased risk of de novo esophageal varices, several studies show that viral clearance does not eliminate the risk of variceal progression, liver decompensation and death in patients with pre-established portal hypertension. Although evidence about the effects of direct antiviral agents (DAAs) on clinically significant outcomes is still scarce and with short follow-up, DAAs can decrease the burden of the disease if patients are timely treated before significant fibrosis and portal hypertension develops. Studies with longer follow-up are waited to establish the real magnitude of hepatitis C treatment on portal hypertension. Future studies should also focus on predictors of portal hypertension resolution since it can influence management and avoid unnecessary monitoring.

  18. Simulgeo and its application for the muon barrel position monitor

    International Nuclear Information System (INIS)

    Brunel, L.

    1999-01-01

    The design process of the Muon Barrel Position Monitor of the CMS (compact muon solenoid) experiment for LHC is at the origin of the need of a software like Simulgeo. The software Silmugeo started to be developed in 1995 in order to allow the study of many systems. The idea of Simulgeo is to automatically make the modelling of a system and automatically construct the design matrix. This paper makes in part 2 an overview of the possibilities of Simulgeo, in part 3 it presents the standard objects. In part 4, it explains the mathematical basis and in part 5 the computing aspect. In part 6, it shows an application to the Muon Barrel Position Monitor Project and, in part 7, it mentions other projects where it has been used

  19. Technology and application of 3D tunnel information monitoring

    Science.gov (United States)

    Li, Changqing; Deng, Hongliang; Chen, Ge; Wang, Simiao; Guo, Yang; Wu, Shenglin

    2015-12-01

    It is very necessary that Implement information monitoring and dynamic construction because of Complex geological environment and lack of basic information in the process of tunnel construction. The monitoring results show that 3 d laser scanning technology and information management system has important theoretical significance and application value to ensure the safety of tunnel construction, rich construction theory and technology. It can be known in real time the deformation information and the construction information in near tunnel workplace and the whole tunnel section in real time. In the meantime, it can be known the deformation regularity in the tunnel excavation process and the early warning and forecasting in the form of graphic and data. In order to determine the reasonable time and provide basis for supporting parameters and lining.

  20. The Effect of Patient Portals on Quality Outcomes and Its Implications to Meaningful Use: A Systematic Review

    Science.gov (United States)

    2015-01-01

    Background The Health Information Technology for Economic and Clinical Health (HITECH) Act imposes pressure on health care organizations to qualify for “Meaningful Use”. It is assumed that portals should increase patient participation in medical decisions, but whether or not the use of portals improves outcomes remains to be seen. Objective The purpose of this systemic review is to outline and summarize study results on the effect of patient portals on quality, or chronic-condition outcomes as defined by the Agency for Healthcare Research and Quality, and its implications to Meaningful Use since the beginning of 2011. This review updates and builds on the work by Ammenwerth, Schnell-Inderst, and Hoerbst. Methods We performed a systematic literature search in PubMed, CINAHL, and Google Scholar. We identified any data-driven study, quantitative or qualitative, that examined a relationship between patient portals, or patient portal features, and outcomes. We also wanted to relate the findings back to Meaningful Use criteria. Over 4000 articles were screened, and 27 were analyzed and summarized for this systematic review. Results We identified 26 studies and 1 review, and we summarized their findings and applicability to our research question. Very few studies associated use of the patient portal, or its features, to improved outcomes; 37% (10/27) of papers reported improvements in medication adherence, disease awareness, self-management of disease, a decrease of office visits, an increase in preventative medicine, and an increase in extended office visits, at the patient’s request for additional information. The results also show an increase in quality in terms of patient satisfaction and customer retention, but there are weak results on medical outcomes. Conclusions The results of this review demonstrate that more health care organizations today offer features of a patient portal than in the review published in 2011. Articles reviewed rarely analyzed a full

  1. The effect of patient portals on quality outcomes and its implications to meaningful use: a systematic review.

    Science.gov (United States)

    Kruse, Clemens Scott; Bolton, Katy; Freriks, Greg

    2015-02-10

    The Health Information Technology for Economic and Clinical Health (HITECH) Act imposes pressure on health care organizations to qualify for "Meaningful Use". It is assumed that portals should increase patient participation in medical decisions, but whether or not the use of portals improves outcomes remains to be seen. The purpose of this systemic review is to outline and summarize study results on the effect of patient portals on quality, or chronic-condition outcomes as defined by the Agency for Healthcare Research and Quality, and its implications to Meaningful Use since the beginning of 2011. This review updates and builds on the work by Ammenwerth, Schnell-Inderst, and Hoerbst. We performed a systematic literature search in PubMed, CINAHL, and Google Scholar. We identified any data-driven study, quantitative or qualitative, that examined a relationship between patient portals, or patient portal features, and outcomes. We also wanted to relate the findings back to Meaningful Use criteria. Over 4000 articles were screened, and 27 were analyzed and summarized for this systematic review. We identified 26 studies and 1 review, and we summarized their findings and applicability to our research question. Very few studies associated use of the patient portal, or its features, to improved outcomes; 37% (10/27) of papers reported improvements in medication adherence, disease awareness, self-management of disease, a decrease of office visits, an increase in preventative medicine, and an increase in extended office visits, at the patient's request for additional information. The results also show an increase in quality in terms of patient satisfaction and customer retention, but there are weak results on medical outcomes. The results of this review demonstrate that more health care organizations today offer features of a patient portal than in the review published in 2011. Articles reviewed rarely analyzed a full patient portal but instead analyzed features of a portal

  2. LifeWatchGreece Portal development: architecture, implementation and challenges for a biodiversity research e-infrastructure.

    Science.gov (United States)

    Gougousis, Alexandros; Bailly, Nicolas

    2016-01-01

    Biodiversity data is characterized by its cross-disciplinary character, the extremely broad range of data types and structures, and the plethora of different data sources providing resources for the same piece of information in a heterogeneous way. Since the web inception two decades ago, there are multiple initiatives to connect, aggregate, share, and publish biodiversity data, and to establish data and work flows in order to analyze them. The European program LifeWatch aims at establishing a distributed network of nodes implementing virtual research environment in Europe to facilitate the work of biodiversity researchers and managers. LifeWatchGreece is one of these nodes where a portal was developed offering access to a suite of virtual laboratories and e-services. Despite its strict definition in information technology, in practice "portal" is a fairly broad term that embraces many web architectures. In the biodiversity domain, the term "portal" is usually used to indicate either a web site that provides access to a single or an aggregation of data repositories (like: http://indiabiodiversity.org/, http://www.mountainbiodiversity.org/, http://data.freshwaterbiodiversity.eu), a web site that gathers information about various online biodiversity tools (like http://test-eubon.ebd.csic.es/, http://marine.lifewatch.eu/) or a web site that just gathers information and news about the biodiversity domain (like http://chm.moew.government.bg). LifeWatchGreece's portal takes the concept of a portal a step further. In strict IT terms, LifeWatchGreece's portal is partly a portal, partly a platform and partly an aggregator. It includes a number of biodiversity-related web tools integrated into a centrally-controlled software ecosystem. This ecosystem includes subsystems for access control, traffic monitoring, user notifications and web tool management. These subsystems are shared to all the web tools that have been integrated to the portal and thereby are part of this

  3. Angiography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E

    1982-04-05

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology.

  4. Angiography in portal hypertension

    International Nuclear Information System (INIS)

    Zeitler, E.

    1982-01-01

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology. (orig.) [de

  5. Application of network technology to Remote Monitoring System

    International Nuclear Information System (INIS)

    Johnson, C.S.; Sorokowski, D.L.; Veevers, K.

    1994-01-01

    The Australian Safeguards Office (ASO) and the US Department of Energy (DOE) have sponsored work under a bilateral agreement to implement a Remote Monitoring System (RMS) at an Australian nuclear site operated by the Australian Nuclear Science and Technology Organization (ANSTO). The RMS, designed by Sandia National Laboratories (SNL), was installed in February 1994 at the Dry Spent Fuel Storage Facility (DSFSF) located at Lucas Heights, Australia. The RMS was designed to test a number of different concepts that would be useful for unattended remote monitoring activities. The DSFSF located in Building 27 is a very suitable test site for a RMS. The RMS uses a network of low cost nodes to collect data from a number of different sensors and security devices. Different sensors and detection devices have been installed to study how they can be used to complement each other for C/S applications. The data collected from the network will allow a comparison of how the various types of sensors perform under the same set of conditions. A video system using digital compression collects digital images and stores them on a hard drive and a digital optical disk. Data and images from the storage area are remotely monitored via telephone from Canberra, Australia and Albuquerque, NM, USA. These remote monitoring stations operated by ASO and SNL respectively, can retrieve data and images from the RMS computer at the DSFSF. The data and images are encrypted before transmission. The Remote Monitoring System field tests have been operational for six months with good test results. Sensors have performed well and the digital images have excellent resolution. The hardware and software have performed reliably without any major difficulties. This paper summarizes the highlights of the prototype system and the ongoing field tests

  6. Portal Annular Pancreas

    Science.gov (United States)

    Harnoss, Jonathan M.; Harnoss, Julian C.; Diener, Markus K.; Contin, Pietro; Ulrich, Alexis B.; Büchler, Markus W.; Schmitz-Winnenthal, Friedrich H.

    2014-01-01

    Abstract Portal annular pancreas (PAP) is an asymptomatic congenital pancreas anomaly, in which portal and/or mesenteric veins are encased by pancreas tissue. The aim of the study was to determine the role of PAP in pancreatic surgery as well as its management and potential complication, specifically, postoperative pancreatic fistula (POPF). On the basis of a case report, the MEDLINE and ISI Web of Science databases were systematically reviewed up to September 2012. All articles describing a case of PAP were considered. In summary, 21 studies with 59 cases were included. The overall prevalence of PAP was 2.4% and the patients' mean (SD) age was 55.9 (16.2) years. The POPF rate in patients with PAP (12 pancreaticoduodenectomies and 3 distal pancreatectomies) was 46.7% (in accordance with the definition of the International Study Group of Pancreatic Surgery). Portal annular pancreas is a quite unattended pancreatic variant with high prevalence and therefore still remains a clinical challenge to avoid postoperative complications. To decrease the risk for POPF, attentive preoperative diagnostics should also focus on PAP. In pancreaticoduodenectomy, a shift of the resection plane to the pancreas tail should be considered; in extensive pancreatectomy, coverage of the pancreatic remnant by the falciform ligament could be a treatment option. PMID:25207658

  7. Obliterative portal venopathy without portal hypertension: an underestimated condition.

    Science.gov (United States)

    Guido, Maria; Sarcognato, Samantha; Sonzogni, Aurelio; Lucà, Maria Grazia; Senzolo, Marco; Fagiuoli, Stefano; Ferrarese, Alberto; Pizzi, Marco; Giacomelli, Luciano; Colloredo, Guido

    2016-03-01

    Obliterative portal venopathy without portal hypertension has been described by a single study in a limited number of patients, thus very little is known about this clinical condition. This study aimed to investigate the prevalence of obliterative portal venopathy and its clinical-pathological correlations in patients with cryptogenic chronic liver test abnormalities without clinical signs of portal hypertension. We analysed 482 liver biopsies from adults with non-cirrhotic cryptogenic chronic liver disorders and without any clinical signs of portal hypertension, consecutively enrolled in a 5-year period. Twenty cases of idiopathic non-cirrhotic portal hypertension diagnosed in the same period, were included for comparison. Histological findings were matched with clinical and laboratory features. Obliterative portal venopathy was identified in 94 (19.5%) of 482 subjects and in all 20 cases of idiopathic non-cirrhotic portal hypertension: both groups shared the entire spectrum of histological changes described in the latter condition. The prevalence of incomplete fibrous septa and nodular regenerative hyperplasia was higher in the biopsies of idiopathic non-cirrhotic portal hypertension (P = 0.006 and P = 0.002), a possible hint of a more advanced stage of the disease. The two groups also shared several clinical laboratory features, including a similar liver function test profile, concomitant prothrombotic conditions and extrahepatic autoimmune disorders. Obliterative portal venopathy occurs in a substantial proportion of patients with unexplained chronic abnormal liver function tests without portal hypertension. The clinical-pathological profile of these subjects suggests that they may be in an early (non-symptomatic) stage of idiopathic non-cirrhotic portal hypertension. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Portal hemodynamics in chronic portal-systemic encephalopathy

    International Nuclear Information System (INIS)

    Takashi, Motohide; Igarashi, Masahiko; Hino, Shinichi; Takayasu, Kenichi; Goto, Nobuaki; Musha, Hirotaka; Ohnishi, Kunihiko; Okuda, Kunio

    1985-01-01

    A portal hemodynamic study was made in 7 consecutive patients with chronic portal-systemic encephalopathy by percutaneous transhepatic catheterization of the portal vein and injecting contrast medium into the superior mesenteric vein or by superior mesenteric arterial portography in comparison with patients without encephalopathy studied by percutaneous catheterization of these veins. It is suggested that chronic portal-systemic encephalopathy is a result of a large collateral route shunting a large proportion of the superior mesenteric venous blood into systemic circulation, and that development of such collaterals precludes formation of large esophageal varices. (Auth.)

  9. Fiber optic interferometry for industrial process monitoring and control applications

    Science.gov (United States)

    Marcus, Michael A.

    2002-02-01

    Over the past few years we have been developing applications for a high-resolution (sub-micron accuracy) fiber optic coupled dual Michelson interferometer-based instrument. It is being utilized in a variety of applications including monitoring liquid layer thickness uniformity on coating hoppers, film base thickness uniformity measurement, digital camera focus assessment, optical cell path length assessment and imager and wafer surface profile mapping. The instrument includes both coherent and non-coherent light sources, custom application dependent optical probes and sample interfaces, a Michelson interferometer, custom electronics, a Pentium-based PC with data acquisition cards and LabWindows CVI or LabView based application specific software. This paper describes the development evolution of this instrument platform and applications highlighting robust instrument design, hardware, software, and user interfaces development. The talk concludes with a discussion of a new high-speed instrument configuration, which can be utilized for high speed surface profiling and as an on-line web thickness gauge.

  10. The ATLAS Wide-Range Database & Application Monitoring

    CERN Document Server

    Vasileva, Petya Tsvetanova; The ATLAS collaboration

    2018-01-01

    In HEP experiments at LHC the database applications often become complex by reflecting the ever demanding requirements of the researchers. The ATLAS experiment has several Oracle DB clusters with over 216 database schemes each with its own set of database objects. To effectively monitor them, we designed a modern and portable application with exceptionally good characteristics. Some of them include: concise view of the most important DB metrics; top SQL statements based on CPU, executions, block reads, etc.; volume growth plots per schema and DB object type; database jobs section with signaling for problematic ones; in-depth analysis in case of contention on data or processes. This contribution describes also the technical aspects of the implementation. The project can be separated into three independent layers. The first layer consists in highly-optimized database objects hiding all complicated calculations. The second layer represents a server providing REST access to the underlying database backend. The th...

  11. Imagery spectroscopy application for Super Fund mining waste monitoring

    Science.gov (United States)

    Roper, William E.

    2001-06-01

    Image spectroscopy was used to evaluate iron oxide acid mine drainage contamination at two U.S. Environmental Protection Agency Super Fund sites located in Colorado and New Mexico. The AVIRIS hyper-spectral remote sensing system developed by the Jet Propulsion Laboratory was used to collect the imagery data used in the analysis. The paper presents an overview of mining methods used in the area of the study, the environmental risks of acid mine drainage and the AVIRIS hyper-spectral sensing system. The two sites evaluated are located in Leadville, Colorado and the Ray Mine site in New Mexico. Imagery spectroscopy was evaluated at these two sites for identifying potential mineral pollutants and mapping their location for cleanup planning and monitoring applications. Results indicate the technology can be a very useful tool for this type of application and location.

  12. Radon monitoring and its application for earthquake prediction

    International Nuclear Information System (INIS)

    Ramchandran, T.V.; Shaikh, A.N.; Khan, A.H.; Mayya, Y.S.; Puranik, V.D.; Venkat Raj, V.

    2004-12-01

    Concentrations ofa wide range of terrestrial gases containing radionuclides like 222 Rn (Radon), H 2 (Hydrogen), Hg (Mercury), CO 2 (Carbon dioxide) and He 4 (Helium) in ground water and soil air have commonly been found to be anomalously high along active faults, suggesting that these faults may be the path for least resistance for the out gassing processes of the solid earth. Among the naturally occurring radionucludes, the 238 U decay series has received great attention in connection with the earthquake prediction and monitoring research all over the world. Due to its nearly ubiquitous occurrence, appreciable abundance, chemical inactivity and convenient half-life (3.823 d), 222 Rn in the 238 U series is the most extensively studied one in this regard. In this report, a brief account of the application of 222 Rn monitoring carried out all over the world, studies carried out in India, modeling of earthquake predictions, measurement techniques, measuring equipments, its availability in India, Indian radon monitoring programme and its prospects are presented. (author)

  13. [Application of lysosomal detection in marine pollution monitoring: research progress].

    Science.gov (United States)

    Weng, You-Zhu; Fang, Yong-Qiang; Zhang, Yu-Sheng

    2013-11-01

    Lysosome is an important organelle existing in eukaryotic cells. With the development of the study on the structure and function of lysosome in recent years, lysosome is considered as a target of toxic substances on subcellular level, and has been widely applied abroad in marine pollution monitoring. This paper summarized the biological characteristics of lysosomal marker enzyme, lysosome-autophagy system, and lysosomal membrane, and introduced the principles and methods of applying lysosomal detection in marine pollution monitoring. Bivalve shellfish digestive gland and fish liver are the most sensitive organs for lysosomal detection. By adopting the lysosomal detection techniques such as lysosomal membrane stability (LMS) test, neutral red retention time (NRRT) assay, morphological measurement (MM) of lysosome, immunohistochemical (Ih) assay of lysosomal marker enzyme, and electron microscopy (EM), the status of marine pollution can be evaluated. It was suggested that the lysosome could be used as a biomarker for monitoring marine environmental pollution. The advantages and disadvantages of lysosomal detection and some problems worthy of attention were analyzed, and the application prospects of lysosomal detection were discussed.

  14. Feasibility of a Website and a Hospital-Based Online Portal for Young Adults With Juvenile Idiopathic Arthritis: Views and Experiences of Patients.

    Science.gov (United States)

    Ammerlaan, Judy Jw; Scholtus, Lieske W; Drossaert, Constance Hc; van Os-Medendorp, Harmieke; Prakken, Berent; Kruize, Aike A; Bijlsma, Johannes Jw

    2015-08-14

    To improve knowledge and to encourage active involvement of young adults with juvenile idiopathic arthritis (JIA), an informative website with written and video information and an online portal with access to the personal medical record, self-monitoring, and e-consult functionalities were developed. Before implementing these applications in daily practice, it is important to gain insight into their feasibility in terms of ease of use, perceived usefulness and intention to use. The aim of this study was to evaluate and to examine the feasibility of the website and the online portal for young adults with JIA. A qualitative, feasibility study was conducted among the first users: 13 young adults with JIA. After provided access to the website and online portal, patients were interviewed on perceived usefulness, ease of use, and intention to (re)use the applications. Participants in the study considered the website and online portal as useful and easy-to-use. New medical information and feedback would motivate them to revisit the applications again. On the website, videos showing other young adults, telling how they handle their condition, were found as the most useful. On the portal, access to their medical records was most appreciated: it made the young JIA patients feel in control and it helped them monitor symptoms and disease activity. e-consults were thought to facilitate communication with physicians. The young adults considered both the website and the online portal as feasible, but they also had valuable suggestions to improve accessibility and use. Based on these findings, a news and event section was added on the website and a direct link was made to a discussion board and social media. To provide and support health information, the website is actively used in daily care. Considering the online portal, the use of self-monitoring tools and e-consult can be stimulated if there is direct linkage to treatment and feedback from the multidisciplinary team

  15. Knowledge Portals: Ontologies at Work

    OpenAIRE

    Staab, Steffen; Maedche, Alexander

    2001-01-01

    Knowledge portals provide views onto domain-specific information on the World Wide Web, thus helping their users find relevant, domain-specific information. The construction of intelligent access and the contribution of information to knowledge portals, however, remained an ad hoc task, requiring extensive manual editing and maintenance by the knowledge portal providers. To diminish these efforts, we use ontologies as a conceptual backbone for providing, accessing, and structuring information...

  16. Duplex sonography in portal hypertension

    International Nuclear Information System (INIS)

    Kwon, Hyuk Po; Jang, J. C.; Park, B. H.

    1990-01-01

    We measure the diameter and blood velocity of the portal vein in 50 patients with cirrhosis of the liver and 40 healthy subjects, and calculated cross sectional area, mean blood flow velocity, blood flow volume and congestion index. In patients with cirrhosis of the liver, the cross sectional area of the portal vein was significantly increased: the mean blood flow volume was significantly reduced; the blood flow volume was significantly increased; the congestion index of the portal vein was significantly increased. Duples sonography may play an important role in the diagnosis of portal hypertension

  17. Development of the image registration program for portal and DRR images in radiation therapy

    International Nuclear Information System (INIS)

    Watanabe, Hiroyuki; Ito, Takeshi; Nakazeko, Kazuma; Tachibana, Atsuhi; Hashimoto, Takeyuki; Shinohara, Hiroyuki

    2012-01-01

    In this article, the authors propose an image registration program of portal images and digitally reconstructed radiography (DRR) images used as simulation images for external beam radiation therapy planning. First, the center of the radiation field in a portal image taken using a computed radiograhy cassette is matched to the center of the portal image. Then scale points projected on a DRR image and the portal image are deleted, and the portal image with the radiation field is extracted. Registration of the DRR and portal images is performed using mutual information as the registration criterion. It was found that the absolute displacement misregistrations in two directions (x, y) were 1.2±0.7 mm and 0.5±0.3 mm, respectively, and rotation disagreement about the z axis 0.3±0.3deg. It was concluded the proposed method was applicable to image registration of portal and DRR images in radiation therapy. (author)

  18. PSUP: A Planetary SUrface Portal

    Science.gov (United States)

    Poulet, F.; Quantin-Nataf, C.; Ballans, H.; Dassas, K.; Audouard, J.; Carter, J.; Gondet, B.; Lozac'h, L.; Malapert, J.-C.; Marmo, C.; Riu, L.; Séjourné, A.

    2018-01-01

    The large size and complexity of planetary data acquired by spacecraft during the last two decades create a demand within the planetary community for access to the archives of raw and high level data and for the tools necessary to analyze these data. Among the different targets of the Solar System, Mars is unique as the combined datasets from the Viking, Mars Global Surveyor, Mars Odyssey, Mars Express and Mars Reconnaissance Orbiter missions provide a tremendous wealth of information that can be used to study the surface of Mars. The number and the size of the datasets require an information system to process, manage and distribute data. The Observatories of Paris Sud (OSUPS) and Lyon (OSUL) have developed a portal, called PSUP (Planetary SUrface Portal), for providing users with efficient and easy access to data products dedicated to the Martian surface. The objectives of the portal are: 1) to allow processing and downloading of data via a specific application called MarsSI (Martian surface data processing Information System); 2) to provide the visualization and merging of high level (image, spectral, and topographic) products and catalogs via a web-based user interface (MarsVisu), and 3) to distribute some of these specific high level data with an emphasis on products issued by the science teams of OSUPS and OSUL. As the MarsSI service is extensively described in a companion paper (Quantin-Nataf et al., companion paper, submitted to this special issue), the present paper focus on the general architecture and the functionalities of the web-based user interface MarsVisu. This service provides access to many data products for Mars: albedo, mineral and thermal inertia global maps from spectrometers; mosaics from imagers; image footprints and rasters from the MarsSI tool; high level specific products (defined as catalogs or vectors). MarsVisu can be used to quickly assess the visualized processed data and maps as well as identify areas that have not been mapped yet

  19. The Protein Model Portal.

    Science.gov (United States)

    Arnold, Konstantin; Kiefer, Florian; Kopp, Jürgen; Battey, James N D; Podvinec, Michael; Westbrook, John D; Berman, Helen M; Bordoli, Lorenza; Schwede, Torsten

    2009-03-01

    Structural Genomics has been successful in determining the structures of many unique proteins in a high throughput manner. Still, the number of known protein sequences is much larger than the number of experimentally solved protein structures. Homology (or comparative) modeling methods make use of experimental protein structures to build models for evolutionary related proteins. Thereby, experimental structure determination efforts and homology modeling complement each other in the exploration of the protein structure space. One of the challenges in using model information effectively has been to access all models available for a specific protein in heterogeneous formats at different sites using various incompatible accession code systems. Often, structure models for hundreds of proteins can be derived from a given experimentally determined structure, using a variety of established methods. This has been done by all of the PSI centers, and by various independent modeling groups. The goal of the Protein Model Portal (PMP) is to provide a single portal which gives access to the various models that can be leveraged from PSI targets and other experimental protein structures. A single interface allows all existing pre-computed models across these various sites to be queried simultaneously, and provides links to interactive services for template selection, target-template alignment, model building, and quality assessment. The current release of the portal consists of 7.6 million model structures provided by different partner resources (CSMP, JCSG, MCSG, NESG, NYSGXRC, JCMM, ModBase, SWISS-MODEL Repository). The PMP is available at http://www.proteinmodelportal.org and from the PSI Structural Genomics Knowledgebase.

  20. CT portal venography manifestations of portal collateral circulation in patients with portal hypertension due to cirrhosis

    International Nuclear Information System (INIS)

    Ni Ming; Lv Weifu; Deng Kexue

    2009-01-01

    Objective: To analyze CT portal venography (CTPV) manifestations of portal collateral circulation in patients with cirrhosis by using a 16-detector row spiral CT scanner. Methods: CTPV was performed in 36 patients with portal hypertension due to cirrhosis, the diagnosis was proved by clinical data, hepatic function findings and imaging signs. By using post-processing reconstruction technique, 3D images of portal venous system and portal collateral circulation were obtained. Results: CTPV images displayed the portal venous system and its collateral circulation stereoscopically. Of 36 patients, left gastric varices were seen in 29(80.6%), lower esophageal varices in 18(50.0%), short gastric or posterior gastric varices in 15(41.7%), paraesophageal varices in 9(25.0%), gastro-renal or splenorenal shunts in 8(22.2%), spongelike transformation of portal vein in 7(19.4%), paraumbilical and abdominal wall varices in 6(16.7%), congenital cavernous in 6(16.7%) and paravertebral venous shunts in 4(11.1%). Conclusion: CTPV can well display the site, extent and severity of the portal collateral circulation in patients with portal hypertension due to cirrhosis,which is of great clinical importance for judging the patient's condition, for selecting therapeutic protocols and for estimating prognosis. (authors)

  1. The Seed Proteome Web Portal

    Directory of Open Access Journals (Sweden)

    Marc eGalland

    2012-06-01

    Full Text Available The Seed Proteome Web Portal (SPWP; http://www.seedproteome.com/ gives access to information both on quantitative seed proteomic data and on seed-related protocols. Firstly, the SPWP provides access to the 475 different Arabidopsis seed proteins annotated from 2 dimensional electrophoresis (2DE maps. Quantitative data are available for each protein according to their accumulation profile during the germination process. These proteins can be retrieved either in list format or directly on scanned 2DE maps. These proteomic data reveal that 40% of seed proteins maintain a stable abundance over germination, up to radicle protrusion. During sensu stricto germination (24 h upon imbibition about 50% of the proteins display quantitative variations, exhibiting an increased abundance (35% or a decreasing abundance (15%. Moreover, during radicle protrusion (24 h to 48 h upon imbibition, 41% proteins display quantitative variations with an increased (23% or a decreasing abundance (18%. In addition, an analysis of the seed proteome revealed the importance of protein post-translational modifications as demonstrated by the poor correlation (r2 = 0.29 between the theoretical (predicted from Arabidopsis genome and the observed protein isoelectric points. Secondly, the SPWP is a relevant technical resource for protocols specifically dedicated to Arabidopsis seed proteome studies. Concerning 2D electrophoresis, the user can find efficient procedures for sample preparation, electrophoresis coupled with gel analysis and protein identification by mass spectrometry, which we have routinely used during the last 12 years. Particular applications such as the detection of oxidized proteins or de novo synthetized proteins radiolabeled by [35S]-methionine are also given in great details. Future developments of this portal will include proteomic data from studies such as dormancy release and protein turnover through de novo protein synthesis analyses during germination.

  2. Lunar and Vesta Web Portals

    Science.gov (United States)

    Law, E.; JPL Luna Mapping; Modeling Project Team

    2015-06-01

    The Lunar Mapping and Modeling Project offers Lunar Mapping and Modeling Portal (http://lmmp.nasa.gov) and Vesta Trek Portal (http://vestatrek.jpl.nasa.gov) providing interactive visualization and analysis tools to enable users to access mapped Lunar and Vesta data products.

  3. Portal dosimetry in wedged beams

    NARCIS (Netherlands)

    Spreeuw, Hanno; Rozendaal, Roel; Camargo, Priscilla; Mans, Anton; Wendling, Markus; Olaciregui-Ruiz, Igor; Sonke, Jan-Jakob; van Herk, Marcel; Mijnheer, Ben

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the

  4. WLCG Operations portal demo tutorial

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This is a navigation through http://wlcg-ops.web.cern.ch/ the Worldwide LHC Computing Grid (WLCG) Operations' portal. In this portal you will find documentation and information about WLCG Operation activities for: System Administrators at the WLCG sites LHC Experiments Operation coordination people, including Task Forces and Working Groups

  5. Applications of polarization speckle in skin cancer detection and monitoring

    Science.gov (United States)

    Lee, Tim K.; Tchvialeva, Lioudmila; Phillips, Jamie; Louie, Daniel C.; Zhao, Jianhua; Wang, Wei; Lui, Harvey; Kalia, Sunil

    2018-01-01

    Polarization speckle is a rapidly developed field. Unlike laser speckle, polarization speckle consists of stochastic interference patterns with spatially random polarizations, amplitudes and phases. We have been working in this exciting research field, developing techniques to generate polarization patterns from skin. We hypothesize that polarization speckle patterns could be used in biomedical applications, especially, for detecting and monitoring skin cancers, the most common neoplasmas for white populations around the world. This paper describes our effort in developing two polarization speckle devices. One of them captures the Stokes parameters So and S1 simultaneously, and another one captures all four Stokes parameters So, S1, S2, and S3 in one-shot, within milliseconds. Hence these two devices could be used in medical clinics and assessed skin conditions in-vivo. In order to validate our hypothesis, we conducted a series of three clinical studies. These are early pilot studies, and the results suggest that the devices have potential to detect and monitor skin cancers.

  6. Imaging monitoring techniques applications in the transient gratings detection

    Science.gov (United States)

    Zhao, Qing-ming

    2009-07-01

    Experimental studies of Degenerate four-wave mixing (DFWM) in iodine vapor at atmospheric pressure and 0℃ and 25℃ are reported. The Laser-induced grating (LIG) studies are carried out by generating the thermal grating using a pulsed, narrow bandwidth, dye laser .A new image processing system for detecting forward DFWM spectroscopy on iodine vapor is reported. This system is composed of CCD camera, imaging processing card and the related software. With the help of the detecting system, phase matching can be easily achieved in the optical arrangement by crossing the two pumps and the probe as diagonals linking opposite corners of a rectangular box ,and providing a way to position the PhotoMultiplier Tube (PMT) . Also it is practical to know the effect of the pointing stability on the optical path by monitoring facula changing with the laser beam pointing and disturbs of the environment. Finally the effects of Photostability of dye laser on the ration of signal to noise in DFWM using forward geometries have been investigated in iodine vapor. This system makes it feasible that the potential application of FG-DFWM is used as a diagnostic tool in combustion research and environment monitoring.

  7. Spectrum Analyzer Application for the Proton Synchrotron Wall Current Monitors

    CERN Document Server

    Limpens, Rik

    The Proton Synchrotron (PS) is a key component in CERN's accelerator complex, where it usually accelerates either protons or heavy ions. The new acquisition system for the PS ring wall current monitors has been installed to be able to perform higher frequency measurements of a beam bunch. This is an important improvement, since the oscillating signals are related to losses of a beam bunch. The main goal of this project is to develop a LabVIEW application running on a Real-Time target to perform continuous and triggered spectral acquisition of a PS beam bunch and to provide a data visualization and analysis tool for the operators and users of the machine.

  8. Analysis of charged particle induced reactions for beam monitor applications

    Energy Technology Data Exchange (ETDEWEB)

    Surendra Babu, K. [IOP, Academia Sinica, Taipe, Taiwan (China); Lee, Young-Ouk [Nuclear Data Evaluation Laboratory, Korea Atomic Energy Research Institute (Korea, Republic of); Mukherjee, S., E-mail: smukherjee_msuphy@yahoo.co.in [Department of Physics, Faculty of Science, M.S. University of Baroda, Vadodara 390 002 (India)

    2012-07-15

    The reaction cross sections for different residual nuclides produced in the charged particle (p, d, {sup 3}He and {alpha}) induced reactions were calculated and compared with the existing experimental data which are important for beam monitoring and medical diagnostic applications. A detailed literature compilation and comparison were made on the available data sets for the above reactions. These calculations were carried out using the statistical model code TALYS up to 100 MeV, which contains Kalbach's latest systematic for the emission of complex particles and complex particle-induced reactions. All optical model calculations were performed by ECIS-03, which is built into TALYS. The level density, optical model potential parameters were adjusted to get the better description of experimental data. Various pre-equilibrium models were used in the present calculations with default parameters.

  9. Application of Risk Management for Control and Monitoring Systems

    CERN Document Server

    Grau, S; Balda, F; Chouvelon, A

    2001-01-01

    This paper presents an application of the state of the art and new trends for risk management of safety-related control and monitoring systems, currently applied in the industry. These techniques not only enable to manage safety and reliability issues but they also help in the control of quality and economic factors affected by the availability and maintenance of the system. The method includes an unambiguous definition of the system in terms of functions and a systematic analysis of hazardous situations, undesired events and possible malfunctions. It also includes the identification and quantification of the risk associated to the system. The required risk reduction is specified in terms of safety integrity levels. The safety integrity level results in requirements, preventive measures, possible improvements and recommendations to assure the satisfactory management of the risk.

  10. Outcomes of pregnancies complicated by liver cirrhosis, portal hypertension, or esophageal varices.

    Science.gov (United States)

    Puljic, Anela; Salati, Jennifer; Doss, Amy; Caughey, Aaron B

    2016-01-01

    To evaluate pregnancy outcomes in women with liver cirrhosis, portal hypertension, or esophageal varices. We analyzed a retrospective cohort of 2,284,218 pregnancies in 2005-2009 recorded in the California Birth Registry database. Utilizing ICD-9 codes we analyzed the following outcomes for liver cirrhosis, portal hypertension, or esophageal varices in pregnancy: preeclampsia (PET), preterm delivery (PTD; Portal hypertension in pregnancy was associated with PTD, LBW, NND, and PPH. Non-bleeding esophageal varices in pregnancy were not associated with the outcomes assessed in a statistically significant manner. One case of bleeding esophageal varices was observed, resulting in PTD with a LBW infant. There were three cases of concomitant portal hypertension or concomitant esophageal varices with cirrhosis in pregnancy. Pregnancy in women with concomitant liver cirrhosis, portal hypertension, or esophageal varices can be successful. However, pregnancy outcomes are worse and may warrant closer antenatal monitoring and patient counseling. Cirrhosis in pregnancy with concomitant portal hypertension or esophageal varices is rare.

  11. Health literacy and patient portals.

    Science.gov (United States)

    Gu, Yulong; Orr, Martin; Warren, Jim

    2015-06-01

    Health literacy has been described as the capacity to obtain, process, and understand basic health information and services needed to make appropriate health decisions. Improving health literacy may serve to promote concordance with therapy, engage patients in their own health care, and improve health outcomes. Patient portal technology aims at enabling patients and families to have easy access to key information in their own medical records and to communicate with their health care providers electronically. However, there is a gap in our understanding of how portals will improve patient outcome. The authors believe patient portal technology presents an opportunity to improve patient concordance with prescribed therapy, if adequate support is provided to equip patients (and family/carers) with the knowledge needed to utilise the health information available via the portals. Research is needed to understand what a health consumer will use patient portals for and how to support a user to realise the technology's potential.

  12. A contact-free respiration monitor for smart bed and ambulatory monitoring applications.

    Science.gov (United States)

    Hart, Adam; Tallevi, Kevin; Wickland, David; Kearney, Robert E; Cafazzo, Joseph A

    2010-01-01

    The development of a contact-free respiration monitor has a broad range of clinical applications in the home and hospital setting. Current approaches suffer from a variety of problems including unreliability, low sensitivity, and high cost. This work describes a novel approach to contact-free respiration monitoring that addresses these shortcomings by employing a highly sensitive capacitance sensor to detect variations in capacitive coupling caused by breathing. A prototype system consisting of a synthetic-metallic pad, sensor electronics, and iPhone interface was built and its performance compared experimentally to the gold standard technique (Respiratory Inductance Plethysmography) on both a healthy volunteer and SimMan robotic mannequin. The prototype sensor effectively captured respiratory movements over breathing rates of 5-55 bpm; achieving an average spectral correlation of 0.88 (CI: 0.86-0.90) and 0.95 (CI: 0.95-0.96) to the gold standard using the SimMan and healthy volunteer respectively.

  13. Integrating Space Communication Network Capabilities via Web Portal Technologies

    Science.gov (United States)

    Johnston, Mark D.; Lee, Carlyn-Ann; Lau, Chi-Wung; Cheung, Kar-Ming; Levesque, Michael; Carruth, Butch; Coffman, Adam; Wallace, Mike

    2014-01-01

    We have developed a service portal prototype as part of an investigation into the feasibility of using Java portlet technology as a means of providing integrated access to NASA communications network services. Portal servers provide an attractive platform for this role due to the various built-in collaboration applications they can provide, combined with the possibility to develop custom inter-operating portlets to extent their functionality while preserving common presentation and behavior. This paper describes various options for integration of network services related to planning and scheduling, and results based on use of a popular open-source portal framework. Plans are underway to develop an operational SCaN Service Portal, building on the experiences reported here.

  14. A Standardization Framework for Electronic Government Service Portals

    Science.gov (United States)

    Sarantis, Demetrios; Tsiakaliaris, Christos; Lampathaki, Fenareti; Charalabidis, Yannis

    Although most eGovernment interoperability frameworks (eGIFs) cover adequately the technical aspects of developing and supporting the provision of electronic services to citizens and businesses, they do not exclusively address several important areas regarding the organization, presentation, accessibility and security of the content and the electronic services offered through government portals. This chapter extends the scope of existing eGIFs presenting the overall architecture and the basic concepts of the Greek standardization framework for electronic government service portals which, for the first time in Europe, is part of a country's eGovernment framework. The proposed standardization framework includes standards, guidelines and recommendations regarding the design, development and operation of government portals that support the provision of administrative information and services to citizens and businesses. By applying the guidelines of the framework, the design, development and operation of portals in central, regional and municipal government can be systematically addressed resulting in an applicable, sustainable and ever-expanding framework.

  15. Grid Portal for Image and Video Processing

    International Nuclear Information System (INIS)

    Dinitrovski, I.; Kakasevski, G.; Buckovska, A.; Loskovska, S.

    2007-01-01

    Users are typically best served by G rid Portals . G rid Portals a re web servers that allow the user to configure or run a class of applications. The server is then given the task of authentication of the user with the Grid and invocation of the required grid services to launch the user's application. PHP is a widely-used general-purpose scripting language that is especially suited for Web development and can be embedded into HTML. PHP is powerful and modern server-side scripting language producing HTML or XML output which easily can be accessed by everyone via web interface (with the browser of your choice) and can execute shell scripts on the server side. The aim of our work is development of Grid portal for image and video processing. The shell scripts contains gLite and globus commands for obtaining proxy certificate, job submission, data management etc. Using this technique we can easily create web interface to the Grid infrastructure. The image and video processing algorithms are implemented in C++ language using various image processing libraries. (Author)

  16. Active Wireless System for Structural Health Monitoring Applications.

    Science.gov (United States)

    Perera, Ricardo; Pérez, Alberto; García-Diéguez, Marta; Zapico-Valle, José Luis

    2017-12-11

    The use of wireless sensors in Structural Health Monitoring (SHM) has increased significantly in the last years. Piezoelectric-based lead zirconium titanate (PZT) sensors have been on the rise in SHM due to their superior sensing abilities. They are applicable in different technologies such as electromechanical impedance (EMI)-based SHM. This work develops a flexible wireless smart sensor (WSS) framework based on the EMI method using active sensors for full-scale and autonomous SHM. In contrast to passive sensors, the self-sensing properties of the PZTs allow interrogating with or exciting a structure when desired. The system integrates the necessary software and hardware within a service-oriented architecture approach able to provide in a modular way the services suitable to satisfy the key requirements of a WSS. The framework developed in this work has been validated on different experimental applications. Initially, the reliability of the EMI method when carried out with the proposed wireless sensor system is evaluated by comparison with the wireless counterpart. Afterwards, the performance of the system is evaluated in terms of software stability and reliability of functioning.

  17. Active Wireless System for Structural Health Monitoring Applications

    Directory of Open Access Journals (Sweden)

    Ricardo Perera

    2017-12-01

    Full Text Available The use of wireless sensors in Structural Health Monitoring (SHM has increased significantly in the last years. Piezoelectric-based lead zirconium titanate (PZT sensors have been on the rise in SHM due to their superior sensing abilities. They are applicable in different technologies such as electromechanical impedance (EMI-based SHM. This work develops a flexible wireless smart sensor (WSS framework based on the EMI method using active sensors for full-scale and autonomous SHM. In contrast to passive sensors, the self-sensing properties of the PZTs allow interrogating with or exciting a structure when desired. The system integrates the necessary software and hardware within a service-oriented architecture approach able to provide in a modular way the services suitable to satisfy the key requirements of a WSS. The framework developed in this work has been validated on different experimental applications. Initially, the reliability of the EMI method when carried out with the proposed wireless sensor system is evaluated by comparison with the wireless counterpart. Afterwards, the performance of the system is evaluated in terms of software stability and reliability of functioning.

  18. Applicability of monitored natural attenuation at radioactively contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-01-15

    The IAEA attaches great importance to the dissemination of information that can assist Member States with the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support a sustainable nuclear fuel cycle and nuclear applications, including managing the legacy of past practices and accidents. Hence, the IAEA has initiated a comprehensive programme of work covering all aspects of environmental remediation including: - Technical and non-technical factors influencing decision making in environmental remediation; - Site characterization techniques and strategies; - Assessment of remediation technologies; - Assessment of technical options for cleanup of contaminated media; - Post-restoration compliance monitoring; - Assessment of the costs of remediation measures. It has been observed that many measures to remove or contain contamination are inefficient below certain concentrations, in general costly, and of a limited lifetime compared with the half-lives of the radionuclides concerned. Dispersed low level contamination poses a particular challenge to those charged with its remediation. Economic considerations in many Member States also result in constraints being placed on resources available to deal with such contamination. Experience has also shown that many techniques are not efficient below certain concentration thresholds or may entail impacts on certain environmental compartments in addition to those due to the contamination itself. This includes doses received by workers on the remediation project. As a result, the concept of relying on geological media to retain contaminants and/or to 'flatten out' concentration/dose peaks is increasingly being discussed in a remediation context. Technical Reports Series No. 424 (Remediation of Sites with Dispersed Radioactive Contamination) examined a variety of technological options for remediating dispersed contamination and concluded that the approaches can be broadly

  19. Applicability of monitored natural attenuation at radioactively contaminated sites

    International Nuclear Information System (INIS)

    2006-01-01

    The IAEA attaches great importance to the dissemination of information that can assist Member States with the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support a sustainable nuclear fuel cycle and nuclear applications, including managing the legacy of past practices and accidents. Hence, the IAEA has initiated a comprehensive programme of work covering all aspects of environmental remediation including: - Technical and non-technical factors influencing decision making in environmental remediation; - Site characterization techniques and strategies; - Assessment of remediation technologies; - Assessment of technical options for cleanup of contaminated media; - Post-restoration compliance monitoring; - Assessment of the costs of remediation measures. It has been observed that many measures to remove or contain contamination are inefficient below certain concentrations, in general costly, and of a limited lifetime compared with the half-lives of the radionuclides concerned. Dispersed low level contamination poses a particular challenge to those charged with its remediation. Economic considerations in many Member States also result in constraints being placed on resources available to deal with such contamination. Experience has also shown that many techniques are not efficient below certain concentration thresholds or may entail impacts on certain environmental compartments in addition to those due to the contamination itself. This includes doses received by workers on the remediation project. As a result, the concept of relying on geological media to retain contaminants and/or to 'flatten out' concentration/dose peaks is increasingly being discussed in a remediation context. Technical Reports Series No. 424 (Remediation of Sites with Dispersed Radioactive Contamination) examined a variety of technological options for remediating dispersed contamination and concluded that the approaches can be broadly

  20. The Portuguese Climate Portal

    Science.gov (United States)

    Gomes, Sandra; Deus, Ricardo; Nogueira, Miguel; Viterbo, Pedro; Miranda, Miguel; Antunes, Sílvia; Silva, Alvaro; Miranda, Pedro

    2016-04-01

    The Portuguese Local Warming Website (http://portaldoclima.pt) has been developed in order to support the society in Portugal in preparing for the adaptation to the ongoing and future effects of climate change. The climate portal provides systematic and easy access to authoritative scientific data ready to be used by a vast and diverse user community from different public and private sectors, key players and decision makers, but also to high school students, contributing to the increase in knowledge and awareness on climate change topics. A comprehensive set of regional climate variables and indicators are computed, explained and graphically presented. Variables and indicators were built in agreement with identified needs after consultation of the relevant social partners from different sectors, including agriculture, water resources, health, environment and energy and also in direct cooperation with the Portuguese National Strategy for Climate Change Adaptation (ENAAC) group. The visual interface allows the user to dynamically interact, explore, quickly analyze and compare, but also to download and import the data and graphics. The climate variables and indicators are computed from state-of-the-art regional climate model (RCM) simulations (e.g., CORDEX project), at high space-temporal detail, allowing to push the limits of the projections down to local administrative regions (NUTS3) and monthly or seasonal periods, promoting local adaptation strategies. The portal provides both historical data (observed and modelled for the 1971-2000 period) and future climate projections for different scenarios (modelled for the 2011-2100 period). A large effort was undertaken in order to quantify the impacts of the risk of extreme events, such as heavy rain and flooding, droughts, heat and cold waves, and fires. Furthermore the different climate scenarios and the ensemble of RCM models, with high temporal (daily) and spatial (~11km) detail, is taken advantage in order to

  1. Transrectal ultrasound applicator for prostate heating monitored using MRI thermometry

    International Nuclear Information System (INIS)

    Smith, Nadine Barrie; Buchanan, Mark T.; Hynynen, Kullervo

    1999-01-01

    Purpose: For potential localized hyperthermia treatment of tumors within the prostate, an ultrasound applicator consisting entirely of nonmagnetic materials for use with magnetic resonance imaging (MRI) has been developed and tested on muscle tissue ex vivo and in vivo. Methods and Materials: A partial-cylindrical intracavitary transducer consisting of 16 elements in a 4 x 4 pattern was constructed. It produced a radially propagating acoustic pressure field. Each element of this array (1.5 x 0.75 cm), operating at 1.5 MHz, could be separately powered to produce a desired energy deposition pattern within a target volume. Spatial and temporal temperature elevations were determined using the temperature-dependent proton resonant frequency (PRF) shift and phase subtraction of MR images acquired during ultrasonic heating. Four rabbits were exposed to the ultrasound to raise the local tissue temperature to 45 deg. C for 25 minutes. Six experiments compared thermocouple temperature results to PRF shift temperature results. Results: The tests showed that the multi-element ultrasound applicator was MRI-compatible and allowed imaging during sonication. The induced temperature distribution could be controlled by monitoring the RF power to each transducer element. Therapeutic temperature elevations were easily achieved in vivo at power levels that were about 16% of the maximum system power. From the six thermocouple experiments, comparison between the thermocouple temperature and the PRF temperature yielded an average error of 0.34 ± 0.36 deg. C. Conclusions: The MRI-compatible intracavitary applicator and driving system was able to control the ultrasound field and temperature pattern in vivo. MRI thermometry using the PRF shift can provide adequate temperature accuracy and stability for controlling the temperature distribution

  2. Congestive index of portal vein

    International Nuclear Information System (INIS)

    Kim, Won Ho; Kim, H. K.; Lee, S. C.; Han, S. H.; Han, K. H.; Chung, J. B.; Choi, H. J.

    1989-01-01

    In patients with portal hypertension, the blood flow volume is maintained despite decreased blood flow velocity due to enlargement of the vascular cross sectional area. Thus, the 'congestion index' of the portal vein, which is the ratio between the cross sectional area (cm2) and the blood flow velocity (cm/sec) determined by a Doppler ultrasonography, may be a sensitive index by which to assess portal hypertension. We performed Doppler ultrasonography on 24 normal subjects, 14 patients with biopsy proved chronic active hepatitis and 55 patients with liver cirrhosis in order to assess the diagnostic value of the congestion index. The cross sectional area of the portal vein was significantly enlarged and the mean blood flow velocity was significantly reduced in patients with liver cirrhosis compared with controls. However, the blood flow volume was no difference. The congestion index of the portal vein was significantly increased in patients with liver cirrhosis (0.113+0.035) compared with patients with chronic active hepatitis(0.078+0.029) (p<0.001) and controls (0.053+0.016) (p<0.001). The sensitivity, specificity and predictability of the congestion index for detection of patients with the cirrhosis of the liver were 76.4%, 100% and 100% respectively, when the normal range was set at mean+2SD. The results suggest that the congestion index of the portal vein may pla a significant role in diagnosis of portal hypertensive patients

  3. Application of Periodic 3DPCM for Core Monitoring System

    International Nuclear Information System (INIS)

    Jeong, Wi-Soo; Lee, Hae-Chan; Kim, Hyeong-Seog; Lee, Chang-Kue; Park, Sang-weon; Baek, Jin-su

    2014-01-01

    The OASIS (Online core Analysis and Simulation System) was developed for WH type PWR which has movable in-core detector. 3DPCM (3D Power Connection Method) was also developed to measure 3D core power distribution using the fixed in-core detector signals and tested for KSNP (Korea Standard Nuclear Plant) such as OPR1000 and APR1400. According to previous study, 3DPCM coupling with neutronics code shows high accuracy. However, this method requires the neutronics code results at each calculation. Therefore, the long calculation time makes it impractical in the online monitoring system requiring the real-time 3D power distribution. In this paper, the 3DPCM based alternative methodology which called periodic 3DPCM is proposed to reduce the calculation time within the reasonable accuracy. The periodic 3DPCM is proposed to reduce the number of neutronics calculation with reasonable accuracy for the application to the online monitoring system development. The periodic 3DPCM is analyzed by 3 cases of sensitivity studies. The errors for the results of power changing operation, ASI changing simulation, and lead control rod insertion are bounded in 0.25%, 1.07%, and 1.15%, respectively. If the update time is shorten as 1 hour, the errors for power changing operation and ASI changing simulation are bounded in 0.07% and 0.56%, respectively. As a result, the update time of 1 hour and prompt update at 30% control rod position change are reasonable considering both conservativeness and effectiveness to update the prediction values. OASIS program utilizing periodic 3DPCM is verified using the plant measurement data and snapshot files which were generated during 45 days operation

  4. Application of Machine Learning to Rotorcraft Health Monitoring

    Science.gov (United States)

    Cody, Tyler; Dempsey, Paula J.

    2017-01-01

    Machine learning is a powerful tool for data exploration and model building with large data sets. This project aimed to use machine learning techniques to explore the inherent structure of data from rotorcraft gear tests, relationships between features and damage states, and to build a system for predicting gear health for future rotorcraft transmission applications. Classical machine learning techniques are difficult, if not irresponsible to apply to time series data because many make the assumption of independence between samples. To overcome this, Hidden Markov Models were used to create a binary classifier for identifying scuffing transitions and Recurrent Neural Networks were used to leverage long distance relationships in predicting discrete damage states. When combined in a workflow, where the binary classifier acted as a filter for the fatigue monitor, the system was able to demonstrate accuracy in damage state prediction and scuffing identification. The time dependent nature of the data restricted data exploration to collecting and analyzing data from the model selection process. The limited amount of available data was unable to give useful information, and the division of training and testing sets tended to heavily influence the scores of the models across combinations of features and hyper-parameters. This work built a framework for tracking scuffing and fatigue on streaming data and demonstrates that machine learning has much to offer rotorcraft health monitoring by using Bayesian learning and deep learning methods to capture the time dependent nature of the data. Suggested future work is to implement the framework developed in this project using a larger variety of data sets to test the generalization capabilities of the models and allow for data exploration.

  5. Information Portal Costs and Benefits

    Directory of Open Access Journals (Sweden)

    Lorena BATAGAN

    2006-01-01

    Full Text Available All transformations of our society are the product of the large use of Information and Communications Technologies (ICT and Internet. ICT are technologies which facilitate communication, processing, and transmission of information by electronic means. It is very important to use the new technologies to the correct value because this determinate an increase of global benefits. Portal provides a consistent way to select, evaluate, prioritize and plan the right information. In research we point the important costs and benefits for an informational portal. The portal for local administrative determinate for citizens the access to information of interest and on the other hand make easier for employer to manage the documents.

  6. The Higgs Portal and Cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Assamagan, Ketevi [Brookhaven National Lab. (BNL), Upton, NY (United States); Chen, Chien-Yi [Perimeter Inst. for Theoretical Physics, Waterloo, ON (Canada); Univ. of Victoria, BC (Canada); Chou, John Paul [Rutgers Univ., Piscataway, NJ (United States); Curtin, David [Univ. of Maryland, College Park, MD (United States); Fedderke, Michael A. [Univ. of Chicago, IL (United States); Gershtein, Yuri [Rutgers Univ., Piscataway, NJ (United States); He, Xiao-Gang [Shanghai Jiao Tong Univ. (China); Klute, Markus [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Kozaczuk, Jonathon [TRIUMF, Vancouver, BC (Canada); Kotwal, Ashutosh [Duke Univ., Durham, NC (United States); Lowette, Steven [Vrije Univ., Brussels (Belgium); No, Jose Miguel [Univ. of Sussex, Brighton (United Kingdom); Plehn, Tilman [Heidelberg Univ. (Germany); Qian, Jianming [Univ. of Michigan, Ann Arbor, MI (United States); Ramsey-Musolf, Michael [Univ. of Massachusetts, Amherst, MA (United States); Safonov, Alexei [Texas A & M Univ., College Station, TX (United States); Shelton, Jessie [Univ. of Illinois, Urbana-Champaign, IL (United States); Spannowsky, Michael [Durham Univ. (United Kingdom); Su, Shufang [Univ. of Arizona, Tucson, AZ (United States); Walker, Devin G. E. [Univ. of Washington, Seattle, WA (United States); Willocq, Stephane [Univ. of Massachusetts, Amherst, MA (United States); Winslow, Peter [Univ. of Massachusetts, Amherst, MA (United States)

    2016-04-18

    Higgs portal interactions provide a simple mechanism for addressing two open problems in cosmology: dark matter and the baryon asymmetry. In the latter instance, Higgs portal interactions may contain the ingredients for a strong first-order electroweak phase transition as well as new CP-violating interactions as needed for electroweak baryogenesis. These interactions may also allow for a viable dark matter candidate. We survey the opportunities for probing the Higgs portal as it relates to these questions in cosmology at the LHC and possible future colliders.

  7. Alarm criteria in radiation portal monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Burr, Tom [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States)]. E-mail: tburr@lanl.gov; Gattiker, James R. [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States); Myers, Kary [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States); Tompkins, George [Los Alamos National Laboratory, Risk Analysis and Decision Support Systems, Stop F609, Los Alamos, NM 87545 (United States)

    2007-05-15

    Gamma detectors at border crossings are intended to detect illicit nuclear material. These detectors collect counts that are used to determine whether to trigger an alarm. Several candidate alarm rules are evaluated, with attention to background suppression caused by the vehicle. Because the count criterion leads to many nuisance alarms and because background suppression by the vehicle is smaller for ratios of counts, analysis of a ratio criterion is included. Detection probability results that consider the effects of 5 factors are given for 2 signal-injection studies, 1 for counts, and 1 for count ratios.

  8. Alarm criteria in radiation portal monitoring

    International Nuclear Information System (INIS)

    Burr, Tom; Gattiker, James R.; Myers, Kary; Tompkins, George

    2007-01-01

    Gamma detectors at border crossings are intended to detect illicit nuclear material. These detectors collect counts that are used to determine whether to trigger an alarm. Several candidate alarm rules are evaluated, with attention to background suppression caused by the vehicle. Because the count criterion leads to many nuisance alarms and because background suppression by the vehicle is smaller for ratios of counts, analysis of a ratio criterion is included. Detection probability results that consider the effects of 5 factors are given for 2 signal-injection studies, 1 for counts, and 1 for count ratios

  9. Monitoring of drilling process with the application of acoustic signal

    Directory of Open Access Journals (Sweden)

    Labaš Milan

    2000-09-01

    Full Text Available Monitoring of rock disintegration process at drilling, scanning of input quantities: thrust F, revolution n and the course of some output quantities: the drilling rate v and the power input P are needed for the control of this process. We can calculate the specific volume work of rock disintegration w and ϕ - quotient of drilling rate v and the specific volume work of disintegration w from the presented quantities.Works on an expertimental stand showed that the correlation relationships between the input and output quantities can be found by scanning the accompanying sound of the drilling proces.Research of the rock disintegration with small-diameter diamond drill tools and different rock types is done at the Institute of Geotechnics. The aim of this research is the possibility of monitoring and controlling the rock disintegration process with the application of acoustic signal. The acoustic vibrations accompanying the drilling process are recorded by a microphone placed in a defined position in the acoustic space. The drilling device (drilling stand, the drilling tool and the rock are the source of sound. Two basic sound states exist in the drilling stand research : the noise at no-load running and the noise at the rotary drilling of rock. Suitable quantities for optimizing the rock disintegration process are searched by the study of the acoustic signal. The dominant frequencies that characterize the disintegration process for the given rock and tool are searched by the analysis of the acoustic signal. The analysis of dominant frequencies indicates the possibility of determining an optimal regime for the maximal drilling rate. Extreme of the specific disintegration energy is determinated by the dispersion of the dominant frequency.The scanned acoustic signal is processed by the Fourier transformation. The Fourier transformation facilitates the distribution of the general non-harmonic periodic process into harmonic components. The harmonic

  10. ATLAS job monitoring in the Dashboard Framework

    CERN Document Server

    Sargsyan, L; The ATLAS collaboration; Campana, S; Karavakis, E; Kokoszkiewicz, L; Saiz, P; Schovancova, J; Tuckett, D

    2012-01-01

    Monitoring of the large-scale data processing of the ATLAS experiment includes monitoring of production and user analysis jobs. The Experiment Dashboard provides a common job monitoring solution, which is shared by ATLAS and CMS experiments. This includes an accounting portal as well as real-time monitoring. Dashboard job monitoring for ATLAS combines information from PanDA job processing database, Production system database and monitoring information from jobs submitted through GANGA to Workload Management System (WMS) or local batch systems. Usage of Dashboard-based job monitoring applications will decrease load on the PanDA database and overcome scale limitations in PanDA monitoring caused by the short job rotation cycle in the PanDA database. Aggregation of the task/job metrics from different sources provides complete view of job processing activity in ATLAS scope.

  11. ATLAS job monitoring in the Dashboard Framework

    International Nuclear Information System (INIS)

    Andreeva, J; Campana, S; Karavakis, E; Kokoszkiewicz, L; Saiz, P; Tuckett, D; Sargsyan, L; Schovancova, J

    2012-01-01

    Monitoring of the large-scale data processing of the ATLAS experiment includes monitoring of production and user analysis jobs. The Experiment Dashboard provides a common job monitoring solution, which is shared by ATLAS and CMS experiments. This includes an accounting portal as well as real-time monitoring. Dashboard job monitoring for ATLAS combines information from the PanDA job processing database, Production system database and monitoring information from jobs submitted through GANGA to Workload Management System (WMS) or local batch systems. Usage of Dashboard-based job monitoring applications will decrease load on the PanDA database and overcome scale limitations in PanDA monitoring caused by the short job rotation cycle in the PanDA database. Aggregation of the task/job metrics from different sources provides complete view of job processing activity in ATLAS scope.

  12. Interventional Radiologic Treatment for Idiopathic Portal Hypertension

    International Nuclear Information System (INIS)

    Hirota, Shozo; Ichikawa, Satoshi; Matsumoto, Shinichi; Motohara, Tomofumi; Fukuda, Tetsuya; Yoshikawa, Takeshi

    1999-01-01

    Purpose: To evaluate the usefulness of interventional radiological treatment for idiopathic portal hypertension. Methods: Between 1995 and 1998, we performed an interventional radiological treatment in five patients with idiopathic portal hypertension, four of whom had refused surgery and one of whom had undergone surgery. Three patients with gastroesophageal varices (GEV) were treated by partial splenic embolization (PSE), one patient with esophageal varices (EV) and massive ascites by transjugular intrahepatic portosytemic shunt (TIPS) and PSE, and one patient with GEV by percutaneous transhepatic obliteration (PTO). Midterm results were analyzed in terms of the effect on esophageal and/or gastric varices. Results: In one woman with severe GEV who underwent three sessions of PSE, there was endoscopic confirmation that the GEV had disappeared. In one man his EV shrunk markedly after two sessions of PSE. In two patients slight reduction of the EV was obtained with one application of PSE combined with endoscopic variceal ligation therapy. PTO for GV in one patient resulted in good control of the varices. All patients have survived for 16-42 months since the first interventional treatment, and varices are well controlled. Conclusion: Interventional radiological treatment is effective for patients with idiopathic portal hypertension, whether or not they have undergone surgery

  13. Monitoring of multiphase flows for superconducting accelerators and others applications

    Science.gov (United States)

    Filippov, Yu. P.; Kakorin, I. D.; Kovrizhnykh, A. M.; Miklayev, V. M.

    2017-07-01

    This paper is a review on implementation of measuring systems for two-phase helium, hydrogen, liquefied natural gas (LNG), and oil-formation/salty water flows. Two types of such systems are presented. The first type is based on two-phase flow-meters combining void fraction radio-frequency (RF) sensors and narrowing devices. They can be applied for superconducting accelerators cooled with two-phase helium, refueling hydrogen system for space ships and some applications in oil production industry. The second one is based on combination of a gamma-densitometer and a narrowing device. These systems can be used to monitor large two-phase LNG and oil-formation water flows. An electronics system based on a modular industrial computer is described as well. The metrological characteristics for different flow-meters are presented and the obtained results are discussed. It is also shown that the experience gained allows separationless flow-meter for three-phase oil-gas-formation water flows to be produced.

  14. Ozone (Environmental Health Student Portal)

    Science.gov (United States)

    Skip Navigation National Library of Medicine Environmental Health Student Portal Connecting Middle School Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor ...

  15. Pesticides (Environmental Health Student Portal)

    Science.gov (United States)

    Skip Navigation National Library of Medicine Environmental Health Student Portal Connecting Middle School Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor ...

  16. Radioisotopic evaluation of portal circulation

    International Nuclear Information System (INIS)

    Maliska, C.; Rosenthal, D.

    1986-01-01

    The use of a radio-tracer of portal circulation through the intestine, should prevent cruel punctures in the portal-vein or spleen as it is usually the case with traditional methods in the study of portal-system. The absorption of I-131 and Tc-99m, previously cheked in rabbits presented similar results in dogs. The time of circulation between terminal large-intestine and the liver (t-RF) was determined by external counting at hepatic level by recording radioactivity variation-time. In healthy animals the t-RF was from 20to 60 seconds, with average time of 42 seconds. In 2 animals with partial binding of portal-vein the t-RF went up to 110 and 120 seconds. (Author) [pt

  17. Splenic embolization in cirrhotic patients with portal hypertension

    International Nuclear Information System (INIS)

    Falappa, P.G.; Cotroneo, A.R.; De Cinque, M.; Maresca, G.; Patane', D.

    1988-01-01

    Over the last four years the authors performed transcatheter embolization of the splenic artery by Gianturco coils in 32 consecutive cirrhotic patients with portal hypertension, splenomegaly, cytopenia and gastro-esophageal varices endoscopically proved. This procedure was especially useful for treatement of splenomegaly and cytopenia because a constant reduction of spleen dimensions and increase in platelet count were registered. The effectiveness of transcatheter embolization and follow-up are based on clinic, hematologic and sonographic findings. Sonographic monitoring is believed to be very useful both to evaluate splenomegaly and signs of portal hypertension and to reveal splenic complications (abscesses). Severe complications have been never registered

  18. Splenic embolization in cirrhotic patients with portal hypertension. US findings

    Energy Technology Data Exchange (ETDEWEB)

    Falappa, P G; Cotroneo, A R; De Cinque, M; Maresca, G; Patane' , D

    1988-01-01

    Over the last four years the authors performed transcatheter embolization of the splenic artery by Gianturco coils in 32 consecutive cirrhotic patients with portal hypertension, splenomegaly, cytopenia and gastro-esophageal varices endoscopically proved. This procedure was especially useful for treatement of splenomegaly and cytopenia because a constant reduction of spleen dimensions and increase in platelet count were registered. The effectiveness of transcatheter embolization and follow-up are based on clinic, hematologic and sonographic findings. Sonographic monitoring is believed to be very useful both to evaluate splenomegaly and signs of portal hypertension and to reveal splenic complications (abscesses). Severe complications have been never registered. 21 refs.

  19. Soil Monitor: an open source web application for real-time soil sealing monitoring and assessment

    Science.gov (United States)

    Langella, Giuliano; Basile, Angelo; Giannecchini, Simone; Iamarino, Michela; Munafò, Michele; Terribile, Fabio

    2016-04-01

    Soil sealing is one of the most important causes of land degradation and desertification. In Europe, soil covered by impermeable materials has increased by about 80% from the Second World War till nowadays, while population has only grown by one third. There is an increasing concern at the high political levels about the need to attenuate imperviousness itself and its effects on soil functions. European Commission promulgated a roadmap (COM(2011) 571) by which the net land take would be zero by 2050. Furthermore, European Commission also published a report in 2011 providing best practices and guidelines for limiting soil sealing and imperviousness. In this scenario, we developed an open source and an open source based Soil Sealing Geospatial Cyber Infrastructure (SS-GCI) named as "Soil Monitor". This tool merges a webGIS with parallel geospatial computation in a fast and dynamic fashion in order to provide real-time assessments of soil sealing at high spatial resolution (20 meters and below) over the whole Italy. Common open source webGIS packages are used to implement both the data management and visualization infrastructures, such as GeoServer and MapStore. The high-speed geospatial computation is ensured by a GPU parallelism using the CUDA (Computing Unified Device Architecture) framework by NVIDIA®. This kind of parallelism required the writing - from scratch - all codes needed to fulfil the geospatial computation built behind the soil sealing toolbox. The combination of GPU computing with webGIS infrastructures is relatively novel and required particular attention at the Java-CUDA programming interface. As a result, Soil Monitor is smart because it can perform very high time-consuming calculations (querying for instance an Italian administrative region as area of interest) in less than one minute. The web application is embedded in a web browser and nothing must be installed before using it. Potentially everybody can use it, but the main targets are the

  20. Final Report for DOE Project: Portal Web Services: Support of DOE SciDAC Collaboratories

    Energy Technology Data Exchange (ETDEWEB)

    Mary Thomas, PI; Geoffrey Fox, Co-PI; Gannon, D; Pierce, M; Moore, R; Schissel, D; Boisseau, J

    2007-10-01

    Grid portals provide the scientific community with familiar and simplified interfaces to the Grid and Grid services, and it is important to deploy grid portals onto the SciDAC grids and collaboratories. The goal of this project is the research, development and deployment of interoperable portal and web services that can be used on SciDAC National Collaboratory grids. This project has four primary task areas: development of portal systems; management of data collections; DOE science application integration; and development of web and grid services in support of the above activities.

  1. The PORTAL OF SOCIAL CONTROL IN HEALTH: academic strategy for strengthening the public health system.

    Directory of Open Access Journals (Sweden)

    Elioenai Dornelles Alves

    2010-12-01

    Full Text Available This portal UNB had the institutional support through DEX and the CPD of UNB creating a website specifi c for hosting applications and certifi cations. referrals this portal, we have the following results:the possibility of disclosing the Journal Management & Health and referrals of local health councils, such as events, debates, legislation and forums. Currently, The portal is hosted by thesite of the Center for Research on Education and Health Promotion - NESPROM of UNB. Continuing this portal was the embryo for creating training courses counselors and multipliers theme social control on health, depending on support for updating and continuity information.

  2. GENIUS/EnginFrame Grid Portal: VOMS Proxy creation, new features and enhancements

    International Nuclear Information System (INIS)

    Ardizzone, V.; Barbaram, R.; Falzone, A.; Emidio, G.; Neri, L.; Scardaci, D.; Venuti, N.

    2007-01-01

    Scientific domain knowledge and tools must be presented to the (non-expert) users in terms of applications without needing to know the underlying details of the Grid Middle wares. GENIUS Grid portal, powered by EnginFrame, is an increasingly popular mechanism for creating customisable, Web-based interfaces to Grid services and resources. This work describes new GENIUS portals capabilities such as portal login, access control, display management, new approach to building reusable portal components as plug ins, better performance results as consequence of EnginFrame core functions improvement. Finally will be described two new tools developed for VOMS Proxy creation and simple JDL composer. (Author)

  3. GENIUS/EnginFrame Grid Portal: VOMS Proxy creation, new features and enhancements

    Energy Technology Data Exchange (ETDEWEB)

    Ardizzone, V.; Barbaram, R.; Falzone, A.; Emidio, G.; Neri, L.; Scardaci, D.; Venuti, N.

    2007-07-01

    Scientific domain knowledge and tools must be presented to the (non-expert) users in terms of applications without needing to know the underlying details of the Grid Middle wares. GENIUS Grid portal, powered by EnginFrame, is an increasingly popular mechanism for creating customisable, Web-based interfaces to Grid services and resources. This work describes new GENIUS portals capabilities such as portal login, access control, display management, new approach to building reusable portal components as plug ins, better performance results as consequence of EnginFrame core functions improvement. Finally will be described two new tools developed for VOMS Proxy creation and simple JDL composer. (Author)

  4. Nuclear Instrumentation Module (NIM) standard logic processor as a portal signal analyzer

    International Nuclear Information System (INIS)

    Minges, G.P.

    1978-01-01

    A general purpose electronic logic processor has been designed into a 2 wide NIM (Nuclear Instrumentation Module) bin module. The unit utilizes a microprocessor to achieve necessary versatility. The processor's first use is as a new generation signal analyzer for use in radiometric personnel and vehicle portal monitors. Significant improvements have been obtained in sensitivity and stability over existing analog discriminators. The new analyzer is presently being used to update personnel and vehicle portal monitoring systems

  5. An automated portal verification system for the tangential breast portal field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Lai, W.; Chen, C. W.; Nelson, D. F.

    1995-01-01

    Hough transform was used to detect and quantify the field edge. Then, the anatomical landmarks (skin line and chest wall) were extracted using both histogram equalization method and Canny edge detector in different subregions. The resulting parameters such as relative shift and rotation from the matching procedure were related to the patient setup variations and were used as the basis for the positioning correction suggestion. Results: The automated portal verification technique was tested using over 100 clinical tangential breast portal images. Both field widths and collimator angles were calculated and were compared to the machine setup parameters. The computer identified anatomical features were evaluated by an expert oncologist by comparing computer-identified edge lines to manual drawings. Results indicated that the computerized algorithm was able to detect the setup field size within an error less than 1.5 mm and collimator angle with an error less than one degree compared to the original field setup. Note that these are the tolerances of the treatment machine. The radiation oncologist rated computer extracted features as absolutely acceptable except 10% of chest walls were acceptable. The subjective evaluation indicated that the computer-identified features was reliable enough for potential clinical applications. The Chamfer matching method provided a matching results between features in two images in an accuracy of within 2 mm. Conclusions: A fully automated portal verification system is developed for the radiation therapy of breast cancer. With a newly developed hierarchical region feature processing and a feature-weighted Chamfer matching techniques, the treatment port for the tangential breast port can be automatically verified. The technique we developed can be also used for the development of automated portal verification systems for the other treatment sites. Our preliminary results showed potentials for the clinical applications

  6. Radiation monitoring methodologies and their applications at BARC site

    International Nuclear Information System (INIS)

    Divkar, J.K.; Chatterjee, M.K.; Patra, R.P; Morali, S.; Singh, Rajvir

    2016-01-01

    Radiation monitoring methodology can be planned for various objectives during normal as well as emergency situations. During radiological emergency, radiation monitoring data provides useful information required for management of the abnormal situation. In order to assess the possible consequences accurately and to implement adequate measure, the emergency management authorities should have a well-prepared monitoring strategy in readiness. Fixed monitoring method is useful to analyze the behavior of nuclear plant site and to develop holistic model for it mobile monitoring is useful for quick impact assessment and will be the backbone of emergency response, particularly in case of non availability of fixed monitoring system caused due to natural disaster like floods, earthquake and tsunami

  7. Galaxy Portal: interacting with the galaxy platform through mobile devices.

    Science.gov (United States)

    Børnich, Claus; Grytten, Ivar; Hovig, Eivind; Paulsen, Jonas; Čech, Martin; Sandve, Geir Kjetil

    2016-06-01

    : We present Galaxy Portal app, an open source interface to the Galaxy system through smart phones and tablets. The Galaxy Portal provides convenient and efficient monitoring of job completion, as well as opportunities for inspection of results and execution history. In addition to being useful to the Galaxy community, we believe that the app also exemplifies a useful way of exploiting mobile interfaces for research/high-performance computing resources in general. The source is freely available under a GPL license on GitHub, along with user documentation and pre-compiled binaries and instructions for several platforms: https://github.com/Tarostar/QMLGalaxyPortal It is available for iOS version 7 (and newer) through the Apple App Store, and for Android through Google Play for version 4.1 (API 16) or newer. geirksa@ifi.uio.no. © The Author 2016. Published by Oxford University Press.

  8. Origins of Portal Hypertension in Nonalcoholic Fatty Liver Disease.

    Science.gov (United States)

    Baffy, Gyorgy

    2018-03-01

    Nonalcoholic fatty liver disease (NAFLD) advanced to cirrhosis is often complicated by clinically significant portal hypertension, which is primarily caused by increased intrahepatic vascular resistance. Liver fibrosis has been identified as a critical determinant of this process. However, there is evidence that portal venous pressure may begin to rise in the earliest stages of NAFLD when fibrosis is far less advanced or absent. The biological and clinical significance of these early changes in sinusoidal homeostasis remains unclear. Experimental and human observations indicate that sinusoidal space restriction due to hepatocellular lipid accumulation and ballooning may impair sinusoidal flow and generate shear stress, increasingly disrupting sinusoidal microcirculation. Sinusoidal endothelial cells, hepatic stellate cells, and Kupffer cells are key partners of hepatocytes affected by NAFLD in promoting endothelial dysfunction through enhanced contractility, capillarization, adhesion and entrapment of blood cells, extracellular matrix deposition, and neovascularization. These biomechanical and rheological changes are aggravated by a dysfunctional gut-liver axis and splanchnic vasoregulation, culminating in fibrosis and clinically significant portal hypertension. We may speculate that increased portal venous pressure is an essential element of the pathogenesis across the entire spectrum of NAFLD. Improved methods of noninvasive portal venous pressure monitoring will hopefully give new insights into the pathobiology of NAFLD and help efforts to identify patients at increased risk for adverse outcomes. In addition, novel drug candidates targeting reversible components of aberrant sinusoidal circulation may prevent progression in NAFLD.

  9. Passive acoustic monitoring of bed load for fluvial applications

    Science.gov (United States)

    The sediment transported as bed load in streams and rivers is notoriously difficult to monitor cheaply and accurately. Passive acoustic methods are relatively simple, inexpensive, and provide spatial integration along with high temporal resolution. In 1963 work began on monitoring emissions from par...

  10. AVISO+, the new reference web portal for altimetry

    Science.gov (United States)

    Rosmorduc, Vinca; Bronner, Emilie; Guinle, Thierry; Maheu, Caroline; Morrow, Rosemary; Nino, Fernando; Birol, Florence

    2014-05-01

    AVISO is the showcase of CNES activities in altimetry. Indeed, the altimetric products processed by the SALP service from CNES (Service d'Altimetrie et de Localisation Precise) are disseminated via AVISO portal since 1995. In recent years, AVISO became a reference in the international oceanographic and altimetry communities, with more than 5,000 registered users in 2013. In 2014 AVISO is enlarging its applications outside the purely ocean-oriented ones, thus becoming AVISO + (www.aviso.altimetry.fr). The portal opens to new applications such as hydrology / coastal / ice. Moreover, it merges with the CTOH (French Observation Service dedicated to satellite altimetry studies) website to provide users with operational as well as demonstration products and expertise in a unique website. We present here all the novelties - new look, new functionnalities, new products, new data access service… hoping to see you soon on our brand-new altimetry portal, www.aviso.altimetry.fr!

  11. [Application of electronic fence technology based on GIS in Oncomelania hupensis snail monitoring].

    Science.gov (United States)

    Zhi-Hua, Chen; Yi-Sheng, Zhu; Zhi-Qiang, Xue; Xue-Bing, Li; Yi-Min, Ding; Li-Jun, Bi; Kai-Min, Gao; You, Zhang

    2017-07-27

    To study the application of Geographic Information System (GIS) electronic fence technique in Oncomelania hupensis snail monitoring. The electronic fence was set around the history and existing snail environments in the electronic map, the information about snail monitoring and controlling was linked to the electronic fence, and the snail monitoring information system was established on these bases. The monitoring information was input through the computer and smart phone. The electronic fence around the history and existing snail environments was set in the electronic map (Baidu map), and the snail monitoring information system and smart phone APP were established. The monitoring information was input and upload real-time, and the snail monitoring information was demonstrated in real time on Baidu map. By using the electronic fence technology based on GIS, the unique "environment electronic archives" for each snail monitoring environment can be established in the electronic map, and real-time, dynamic monitoring and visual management can be realized.

  12. Application of Video Recognition Technology in Landslide Monitoring System

    Directory of Open Access Journals (Sweden)

    Qingjia Meng

    2018-01-01

    Full Text Available The video recognition technology is applied to the landslide emergency remote monitoring system. The trajectories of the landslide are identified by this system in this paper. The system of geological disaster monitoring is applied synthetically to realize the analysis of landslide monitoring data and the combination of video recognition technology. Landslide video monitoring system will video image information, time point, network signal strength, power supply through the 4G network transmission to the server. The data is comprehensively analysed though the remote man-machine interface to conduct to achieve the threshold or manual control to determine the front-end video surveillance system. The system is used to identify the target landslide video for intelligent identification. The algorithm is embedded in the intelligent analysis module, and the video frame is identified, detected, analysed, filtered, and morphological treatment. The algorithm based on artificial intelligence and pattern recognition is used to mark the target landslide in the video screen and confirm whether the landslide is normal. The landslide video monitoring system realizes the remote monitoring and control of the mobile side, and provides a quick and easy monitoring technology.

  13. Portal pressure correlated to visceral circulation times

    Energy Technology Data Exchange (ETDEWEB)

    Friman, L [Serafimerlasarettet, Stockholm (Sweden)

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system.

  14. Portal pressure correlated to visceral circulation times

    International Nuclear Information System (INIS)

    Friman, L.

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system. (Auth.)

  15. Positive identity entry control system with geographically distributed portals and enrollment stations

    International Nuclear Information System (INIS)

    McIntire, J.M.

    1985-01-01

    A positive identity entry control system using distributed processing to allow reliable geographically separated portals and enrollment stations has been installed and is fully operational at a large area DOE site. Identity verification requires a credential, a memorized number and measurement of a physical characteristic of the user. Additionally, all portal activity is monitored by guards. The portal system is dual redundant such that no single point failure will shut down operations. Each portal site maintains its own subset of the master data base so off-site failure of the central data base manager or its communication links will not significantly affect local portal activity. The system is suitable for installations with large populations requiring access control at several remote sites scattered over a large area

  16. Patients' Experiences with and Attitudes towards a Diabetes Patient Web Portal.

    Science.gov (United States)

    Ronda, Maaike C M; Dijkhorst-Oei, Lioe-Ting; Rutten, Guy E H M

    2015-01-01

    A diabetes patient web portal allows patients to access their personal health record and may improve diabetes outcomes; however, patients' adoption is slow. We aimed to get insight into patients' experiences with a web portal to understand how the portal is being used, how patients perceive the content of the portal and to assess whether redesign of the portal might be needed. A survey among 1500 patients with type 1 and type 2 diabetes with a login to a patient portal. 62 primary care practices and one outpatient hospital clinic, using a combined patient portal. We compared patients who requested a login but never used it or once ('early quitters') with patients who used it at least two times ('persistent users'). 632 patients (42.1%) returned the questionnaire. Their mean age was 59.7 years, 63.1% was male and 81.8% had type 2 diabetes. 413 (65.3%) people were persistent users and 34.7% early quitters. In the multivariable analysis, insulin use (OR2.07; 95%CI[1.18-3.62]), experiencing more frequently hyperglycemic episodes (OR1.30;95%CI[1.14-1.49]) and better diabetes knowledge (OR1.02, 95%CI[1.01-1.03]) do increase the odds of being a persistent user. Persistent users perceived the usefulness of the patient portal significantly more favorable. However, they also more decisively declared that the patient portal is not helpful in supporting life style changes. Early quitters felt significantly more items not applicable in their situation compared to persistent users. Both persistent users (69.8%) and early quitters (58.8%) would prefer a reminder function for scheduled visits. About 60% of both groups wanted information about medication and side-effects in their portal. The diabetes patient web portal might be improved significantly by taking into account the patients' experiences and attitudes. We propose creating separate portals for patients on insulin or not.

  17. The specialized portals in the knowledge transfer systems: the ionizing radiation portal http://www.ionizantes.ciemat.es/

    International Nuclear Information System (INIS)

    Arboli, M. Marco; Hernanz, Oscar; Couchoud Gregory, Milagros

    2008-01-01

    Full text: This paper shows the new infrastructure to disseminate RP knowledge and information developed by the community involved in radiation uses. The www.ionizantes.ciemat.es portal has been implemented by CIEMAT and CINDOC- CSIC with the support of the national and international organizations related to the radiation applications. The design and structure of the databases was developed by CIEMAT and CINDOC-CSIC using the experience acquired by both organizations in the knowledge transfer. The initiative aims to establish collaboration with the sector involved in the most important applications of the ionizing radiation uses. The goal is to share resources establishing a new system of information between the experts, researchers and public. The portal also brings the dialogue to the entire sector and provides details of the relevant research projects. The main specific objectives of this portal are: a) To inform about the new projects developed; b) To download publications, reports and papers; c) to learn more about ionizing radiation; d) To promote collaborative knowledge transfer. The portal shows particular relevance to representative international and national organizations, the private sector and the local community relevant organizations. Results: The resources include in the database of the portal are: the agenda, documents, research calls, legislation, research projects, most important journals and summaries, patents and other available tools. The information is presented in a categorized and classified structure. This virtual community offers better knowledge transfer. It also optimizes the communication and research dissemination to the society. (author)

  18. Trajectory Clustering and an Application to Airspace Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — This paper presents a framework aimed at monitoring the behavior of aircraft in a given airspace. Trajectories that constitute typical operations are determined and...

  19. Applications in bridge structure health monitoring using distributed fiber sensing

    Science.gov (United States)

    Feng, Yafei; Zheng, Huan; Ge, Huiliang

    2017-10-01

    In this paper, Brillouin Optical Time Domain Analysis (BOTDA) is proposed to solve the problem that the traditional point sensor is difficult to realize the comprehensive safety monitoring of bridges and so on. This technology not only breaks through the bottleneck of traditional monitoring point sensor, realize the distributed measurement of temperature and strain on a transmission path; can also be used for bridge and other structures of the damage identification, fracture positioning, settlement monitoring. The effectiveness and frontier of the technology are proved by comparing the test of the indoor model beam and the external field bridge, and the significance of the distributed optical fiber sensing technology to the monitoring of the important structure of the bridge is fully explained.

  20. Impedance-based monitoring for tissue engineering applications

    DEFF Research Database (Denmark)

    Canali, Chiara; Heiskanen, Arto; Martinsen, Ø.G.

    2015-01-01

    Impedance is a promising technique for sensing the overall process of tissue engineering. Different electrode configurations can be used to characterize the scaffold that supports cell organization in terms of hydrogel polymerization and degree of porosity, monitoring cell loading, cell...

  1. The Application of Foundation Pit Monitoring Technology to the Excavation

    Directory of Open Access Journals (Sweden)

    Qiu Jin

    2015-01-01

    Full Text Available The foundation pit monitoring plays an important role in the foundation pit supporting projects especially in those deep foundation pit projects. Through the whole monitoring of the foundation pit construction from the excavation to the backfill, we can learn about the forcing and deforming process of the foundation pit supporting system, and grasp the impact of external condition changes on the foundation pit. This paper takes a project in Jinan as an example to establish a specific monitoring program, and then conducts the analysis and evaluation of the monitoring data; the real-time grasp of the foundation pit deformation and internal force changes can help to further ensure the security status of the foundation pit, thus better guiding the construction.

  2. Development and application of all-digital monitoring system

    International Nuclear Information System (INIS)

    Xu Tao; Li Jing; Wang Wei

    2014-01-01

    All digital control system has developed into a mainstream means of monitoring, and achieved information, intelligence, and networking. All-digital control system is characterized by clear image, large transport stream, so the higher the data storage and network bandwidth should be required. Existing analog surveillance system architecture, hardware and software configuration can not meet the requirements of all-digital monitoring system, so how to solve the original analog surveillance system is gradually transformed into fully digital monitoring system, to avoid incompatibility issues in surveillance monitoring system upgrade become a research project. This paper describes the advantages and future direction of megapixels camera and proposes key technologies to solve the resolution and frame rate with the actual project requirements, achieves a core technology of megapixels video surveillance system, and proposes solutions for the actual renovation project problems. (authors)

  3. IOOS Data Portals and Uniform On-line Browse Capabilities

    Science.gov (United States)

    Howard, M.; Currier, R. D.; Kobara, S.; Gayanilo, F.

    2015-12-01

    The Gulf of Mexico Coastal Ocean Observing System Regional Association (GCOOS-RA) is one of eleven Regional Associations organized under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) Program Office. Each of the RAs operate standards-based regional data portals designed to aggregate near real-time and historical observed data and modeled outputs from distributed providers and to offer these and derived products in standardized ways to a diverse set of users. The RA's portals are based on the IOOS Data and Communications Plan which describes the functional elements needed for an interoperable system. One of these elements is called "Uniform On-line Browse" which is an informational service designed primarily to visualize the inventory of a portal. An on-line browse service supports the end user's need to discover what parameters are available, to learn the spatial and temporal extend of the holdings, and to examine the character of the data (e.g, variability, gappiness, etc). These pieces of information help the end user decide if the data are fit for his/her purpose and to construct valid data requests. Note that on-line browse is a distinctly different activity than data analysis because it seeks to yield knowledge about the inventory and not about what the data mean. "Uniform" on-line browse is a service that takes advantage of the standardization of the data portal's data access points. Most portals represent station locations on a map. This is a view of the data inventory but these plots are rarely generated by pulling data through the standards-based services offered to the end users but through methods only available to the portal programmers. This work will present results of Uniform On-line browse tools developed within GCOOS-RA and their applicability to other RA portals.

  4. Prospective clinical evaluation of an electronic portal imaging device

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Graham, Mary V.; Bosch, Walter R.; Wong, John; Gerber, Russell L.; Cheng, Abel; Tinger, Alfred; Valicenti, Richard K.

    1996-01-01

    Purpose: To determine whether the clinical implementation of an electronic portal imaging device can improve the precision of daily external beam radiotherapy. Methods and Materials: In 1991, an electronic portal imaging device was installed on a dual energy linear accelerator in our clinic. After training the radiotherapy technologists in the acquisition and evaluation of portal images, we performed a randomized study to determine whether online observation, interruption, and intervention would result in more precise daily setup. The patients were randomized to one of two groups: those whose treatments were actively monitored by the radiotherapy technologists and those that were imaged but not monitored. The treating technologists were instructed to correct the following treatment errors: (a) field placement error (FPE) > 1 cm; (b) incorrect block; (c) incorrect collimator setting; (d) absent customized block. Time of treatment delivery was recorded by our patient tracking and billing computers and compared to a matched set of patients not participating in the study. After the patients radiation therapy course was completed, an offline analysis of the patient setup error was planned. Results: Thirty-two patients were treated to 34 anatomical sites in this study. In 893 treatment sessions, 1,873 fields were treated (1,089 fields monitored and 794 fields unmonitored). Ninety percent of the treated fields had at least one image stored for offline analysis. Eighty-seven percent of these images were analyzed offline. Of the 1,011 fields imaged in the monitored arm, only 14 (1.4%) had an intervention recorded by the technologist. Despite infrequent online intervention, offline analysis demonstrated that the incidence of FPE > 10 mm in the monitored and unmonitored groups was 56 out of 881 (6.1%) and 95 out of 595 (11.2%), respectively; p 10 mm was confined to the pelvic fields. The time to treat patients in this study was 10.78 min (monitored) and 10.10 min (unmonitored

  5. Dashboard applications to monitor experiment activities at sites

    Energy Technology Data Exchange (ETDEWEB)

    Andreeva, Julia; Gaidioz, Benjamin; Grigoras, Costin; Kokoszkiewicz, Lukasz; Lanciotti, Elisa; Rocha, Ricardo; Saiz, Pablo; Santinelli, Roberto; Sidorova, Irina; Sciaba, Andrea [CERN, European Organization for Nuclear Research (Switzerland); Belforte, Stefano [INFN Trieste (Italy); Boehm, Max [EDS, an HP Company, Plano, TX (United States); Casajus, Adrian [Universitat de Barcelona (Spain); Flix, Josep [PIC, Port d' Informacio CientIfica, Bellaterra (Spain); Tsaregorodtsev, Andrei, E-mail: Elisa.Lanciotti@cern.c, E-mail: Pablo.Saiz@cern.c [CPPM Marseille (France)

    2010-04-01

    In the framework of a distributed computing environment, such as WLCG, monitoring has a key role in order to keep under control activities going on in sites located in different countries and involving people based in many different sites. To be able to cope with such a large scale heterogeneous infrastructure, it is necessary to have monitoring tools providing a complete and reliable view of the overall performance of the sites. Moreover, the structure of a monitoring system critically depends on the object to monitor and on the users it is addressed to. In this article we will describe two different monitoring systems both aimed to monitor activities and services provided in the WLCG framework, but designed in order to meet the requirements of different users: Site Status Board has an overall view of the services available in all the sites supporting an experiment, whereas Siteview provides a complete view of all the activities going on at a site, for all the experiments supported by the site.

  6. Dashboard applications to monitor experiment activities at sites

    International Nuclear Information System (INIS)

    Andreeva, Julia; Gaidioz, Benjamin; Grigoras, Costin; Kokoszkiewicz, Lukasz; Lanciotti, Elisa; Rocha, Ricardo; Saiz, Pablo; Santinelli, Roberto; Sidorova, Irina; Sciaba, Andrea; Belforte, Stefano; Boehm, Max; Casajus, Adrian; Flix, Josep; Tsaregorodtsev, Andrei

    2010-01-01

    In the framework of a distributed computing environment, such as WLCG, monitoring has a key role in order to keep under control activities going on in sites located in different countries and involving people based in many different sites. To be able to cope with such a large scale heterogeneous infrastructure, it is necessary to have monitoring tools providing a complete and reliable view of the overall performance of the sites. Moreover, the structure of a monitoring system critically depends on the object to monitor and on the users it is addressed to. In this article we will describe two different monitoring systems both aimed to monitor activities and services provided in the WLCG framework, but designed in order to meet the requirements of different users: Site Status Board has an overall view of the services available in all the sites supporting an experiment, whereas Siteview provides a complete view of all the activities going on at a site, for all the experiments supported by the site.

  7. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  8. The MISTRALS programme data portal

    Science.gov (United States)

    Fleury, Laurence; Brissebrat, Guillaume; Belmahfoud, Nizar; Boichard, Jean-Luc; Brosolo, Laetitia; Cloché, Sophie; Descloitres, Jacques; Ferré, Hélène; Focsa, Loredana; Labatut, Laurent; Mastrorillo, Laurence; Mière, Arnaud; Petit de la Villéon, Loïc; Ramage, Karim; Schmechtig, Catherine

    2014-05-01

    Mediterranean Integrated STudies at Regional And Local Scales (MISTRALS) is a decennial programme for systematic observations and research dedicated to the understanding of the Mediterranean Basin environmental process and its evolution under the planet global change. It is composed of eight multidisciplinary projects that cover all the components of the Earth system (atmosphere, ocean, continental surfaces, lithosphere...) and their interactions, many disciplines (physics, chemistry, marine biogeochemistry, biology, geology, sociology...) and different time scales. For example Hydrological cycle in the Mediterranean eXperiment (HyMeX) aims at improving the predictability of rainfall extreme events, and assessing the social and economic vulnerability to extreme events and adaptation capacity, and Paleo Mediterranean Experiment (PaleoMeX) is dedicated to the study of the interactions between climate, societies and civilizations of the Mediterranean world during the last 10000 years. Many long term monitoring research networks are associated with MISTRALS, like Mediterranean Ocean Observing System on Environment (MOOSE), Centre d'Observation Régional pour la Surveillance du Climat et de l'environnement Atmosphérique et océanographique en Méditerranée occidentale (CORSICA) and the environmental observations from Mediterranean Eurocentre for Underwater Sciences and Technologies (MEUST-SE). Therefore, the data generated or used by the different MISTRALS projects are very heterogeneous. They include in situ observations, satellite products, model outputs, qualitative field surveys... Some datasets are automatically produced by operational networks, and others come from research instruments and analysis procedures. They correspond to different time scales (historical time series, observatories, campaigns...) and are managed by different data centres. They originate from many scientific communities, with varied data sharing cultures, specific expectations, and using

  9. The MISTRALS programme data portal

    Science.gov (United States)

    Brissebrat, Guillaume; Belmahfoud, Nizar; Cloché, Sophie; Darras, Sabine; Descloitres, Jacques; Drocourt, Yoann; Ferré, Hélène; Henriot, Nicolas; Ramage, Karim

    2017-04-01

    Mediterranean Integrated STudies at Regional And Local Scales (MISTRALS) is a decennial programme for systematic observations and research dedicated to the understanding of the Mediterranean Basin environmental process and its evolution under the planet global change. It is composed of eight multidisciplinary projects that cover all the components of the Earth system (atmosphere, ocean, continental surfaces, lithosphere...) and their interactions, all the disciplines (physics, chemistry, marine biogeochemistry, biology, geology, sociology…) and different time scales. For example Hydrological cycle in the Mediterranean eXperiment (HyMeX) aims at improving the predictability of rainfall extreme events, and assessing the social and economic vulnerability to extreme events and adaptation capacity. Paleo Mediterranean Experiment (PaleoMeX) is dedicated to the study of the interactions between climate, societies and civilizations of the Mediterranean world during the last 10000 years. Many long term monitoring research networks are associated with MISTRALS, such as Mediterranean Ocean Observing System on Environment (MOOSE), Centre d'Observation Régional pour la Surveillance du Climat et de l'environnement Atmosphérique et océanographique en Méditerranée occidentale (CORSICA) and the environmental observations from Mediterranean Eurocentre for Underwater Sciences and Technologies (MEUST-SE). Therefore, the data generated or used by the different MISTRALS projects are very heterogeneous. They include in situ observations, satellite products, model outputs, social sciences surveys... Some datasets are automatically produced by operational networks, and others come from research instruments and analysis procedures. They correspond to different time scales (historical time series, observatories, campaigns...) and are managed by several data centres. They originate from many scientific communities, with different data sharing practices, specific expectations and using

  10. Pharmacology Portal: An Open Database for Clinical Pharmacologic Laboratory Services.

    Science.gov (United States)

    Karlsen Bjånes, Tormod; Mjåset Hjertø, Espen; Lønne, Lars; Aronsen, Lena; Andsnes Berg, Jon; Bergan, Stein; Otto Berg-Hansen, Grim; Bernard, Jean-Paul; Larsen Burns, Margrete; Toralf Fosen, Jan; Frost, Joachim; Hilberg, Thor; Krabseth, Hege-Merete; Kvan, Elena; Narum, Sigrid; Austgulen Westin, Andreas

    2016-01-01

    More than 50 Norwegian public and private laboratories provide one or more analyses for therapeutic drug monitoring or testing for drugs of abuse. Practices differ among laboratories, and analytical repertoires can change rapidly as new substances become available for analysis. The Pharmacology Portal was developed to provide an overview of these activities and to standardize the practices and terminology among laboratories. The Pharmacology Portal is a modern dynamic web database comprising all available analyses within therapeutic drug monitoring and testing for drugs of abuse in Norway. Content can be retrieved by using the search engine or by scrolling through substance lists. The core content is a substance registry updated by a national editorial board of experts within the field of clinical pharmacology. This ensures quality and consistency regarding substance terminologies and classification. All laboratories publish their own repertoires in a user-friendly workflow, adding laboratory-specific details to the core information in the substance registry. The user management system ensures that laboratories are restricted from editing content in the database core or in repertoires within other laboratory subpages. The portal is for nonprofit use, and has been fully funded by the Norwegian Medical Association, the Norwegian Society of Clinical Pharmacology, and the 8 largest pharmacologic institutions in Norway. The database server runs an open-source content management system that ensures flexibility with respect to further development projects, including the potential expansion of the Pharmacology Portal to other countries. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.

  11. [Applications of spectral analysis technique to monitoring grasshoppers].

    Science.gov (United States)

    Lu, Hui; Han, Jian-guo; Zhang, Lu-da

    2008-12-01

    Grasshopper monitoring is of great significance in protecting environment and reducing economic loss. However, how to predict grasshoppers accurately and effectively is a difficult problem for a long time. In the present paper, the importance of forecasting grasshoppers and its habitat is expounded, and the development in monitoring grasshopper populations and the common arithmetic of spectral analysis technique are illustrated. Meanwhile, the traditional methods are compared with the spectral technology. Remote sensing has been applied in monitoring the living, growing and breeding habitats of grasshopper population, and can be used to develop a forecast model combined with GIS. The NDVI values can be analyzed throughout the remote sensing data and be used in grasshopper forecasting. Hyper-spectra remote sensing technique which can be used to monitor grasshoppers more exactly has advantages in measuring the damage degree and classifying damage areas of grasshoppers, so it can be adopted to monitor the spatial distribution dynamic of rangeland grasshopper population. Differentialsmoothing can be used to reflect the relations between the characteristic parameters of hyper-spectra and leaf area index (LAI), and indicate the intensity of grasshopper damage. The technology of near infrared reflectance spectroscopy has been employed in judging grasshopper species, examining species occurrences and monitoring hatching places by measuring humidity and nutrient of soil, and can be used to investigate and observe grasshoppers in sample research. According to this paper, it is concluded that the spectral analysis technique could be used as a quick and exact tool in monitoring and forecasting the infestation of grasshoppers, and will become an important means in such kind of research for their advantages in determining spatial orientation, information extracting and processing. With the rapid development of spectral analysis methodology, the goal of sustainable monitoring

  12. A portable, automatic SNM monitor for nuclear safeguards: Development, evaluation, and applications

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1993-09-01

    The portable SNM monitor is a lightweight, full-size, automatic monitor, suitable for temporary service (such as demonstrations or for use during maintenance) or as a permanent replacement for hand- held monitors. The authors based the monitor on the TSA Systems, Ltd., modular SNM monitor design and, through evaluation and improvement of the commercial modules, obtained adequate sensitivity in a single- cabinet monitor that is easily portable. Complete monitoring of pedestrians with a single detector cabinet is achieved by requiring the pedestrian to stand in front of the detectors and turn around through 360 deg while being observed by a security inspector. The monitor is available commercially as the TSA Systems Model PMD-701, and it is beginning to be used in both temporary and permanent applications

  13. Application of toxicity monitor using nitrifying bacteria biosensor to sewerage systems.

    Science.gov (United States)

    Inui, T; Tanaka, Y; Okayas, Y; Tanaka, H

    2002-01-01

    Toxic substances may be included in wastewater influent and can damage biological processing of wastewater treatment, therefore continuous toxic-monitoring of wastewater influent is needed. This paper describes the potential toxic-monitoring applications of the toxicity monitor using a nitrifying bacteria biosensor to sewerage systems. The results of sensitivity tests show that aspects of wastewater do not affect the sensor sensitivity and confirm that the sensor can be applied to wastewater monitoring as it is. The monitor with a prototype of filtration system installed in a wastewater treatment plant is able to operate continuously for one month at least after the modification of filtration system and the optimization of operation conditions.

  14. Portal hyperflow in patients with hepatosplenic mansonic schistosomiasis Hiperfluxo portal na forma hepatosplênica da esquistossomose mansônica

    Directory of Open Access Journals (Sweden)

    Roberto de Cleva

    2004-02-01

    Full Text Available PURPOSE: The purpose of this study was to assess portal hemodynamics in patients with portal hypertension due to hepatosplenic schistosomiasis as well as to assess the contribution of splanchnic hyperflow to the pathophysiology of the portal hypertension. METHODS: Sixteen patients with schistosomal portal hypertension and previous history of upper digestive bleeding due to esophageal varices rupture underwent elective esophagogastric devascularization and splenectomy and were prospectively studied. All patients underwent intraoperative invasive hemodynamic portal monitoring with a 4F-thermodilution catheter. The intraoperative portal hemodynamic assessment was conducted after laparotomy (initial and after esophagogastric devascularization (final. RESULTS: The initial portal pressure was elevated (mean 28.5 ± 4.5 mm Hg, and a significant drop of 25% was observed at the end of the surgery (21.9 ± 4.9 mm Hg. The initial portal flow was elevated (mean 1766.9 ± 686.6 mL/min. A significant fall (42% occurred at the end of the surgical procedure (1025.62 ± 338.7 mL/min. Fourteen patients (87.5% presented a portal flow of more than 1200 mL/min, and in 5 cases, values greater than 2000 mL/min were observed. CONCLUSIONS: Esophagogastric devascularization and splenectomy promote a significant reduction of the elevated portal pressure and flow in schistosomal portal hypertension. These data favor the hypothesis of portal hyperflow in the physiopathology of portal hypertension of schistosomiasis.OBJETIVOS: o objetivo do presente estudo é estudar a hemodinâmica portal em pacientes com hipertensão portal secundária a forma hepatoesplênica da esquistossomose e avaliar a contribuição do hiperfluxo esplênico na sua fisiopatologia CASUÍSTICA E MÉTODOS: Foram estudados prospectivamente 16 pacientes portadores de hipertensão portal secundária à forma hepatoesplênica da esquistossomose mansônica com indicação de tratamento cirúrgico. Todos foram

  15. The monitoring and managing application of cloud computing based on Internet of Things.

    Science.gov (United States)

    Luo, Shiliang; Ren, Bin

    2016-07-01

    Cloud computing and the Internet of Things are the two hot points in the Internet application field. The application of the two new technologies is in hot discussion and research, but quite less on the field of medical monitoring and managing application. Thus, in this paper, we study and analyze the application of cloud computing and the Internet of Things on the medical field. And we manage to make a combination of the two techniques in the medical monitoring and managing field. The model architecture for remote monitoring cloud platform of healthcare information (RMCPHI) was established firstly. Then the RMCPHI architecture was analyzed. Finally an efficient PSOSAA algorithm was proposed for the medical monitoring and managing application of cloud computing. Simulation results showed that our proposed scheme can improve the efficiency about 50%. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. The Higgs portal above threshold

    Energy Technology Data Exchange (ETDEWEB)

    Craig, Nathaniel [Department of Physics, University of California,Santa Barbara, CA 93106 (United States); Lou, Hou Keong [Department of Physics, Princeton University,Princeton, NJ 08540 (United States); McCullough, Matthew [Theory Division, CERN,1211 Geneva 23 (Switzerland); Thalapillil, Arun [Department of Physics and Astronomy, Rutgers University,Piscataway, NJ 08854 (United States)

    2016-02-18

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  17. The Higgs portal above threshold

    International Nuclear Information System (INIS)

    Craig, Nathaniel; Lou, Hou Keong; McCullough, Matthew; Thalapillil, Arun

    2016-01-01

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  18. A new rat model of portal hypertension induced by intraportal injection of microspheres

    Science.gov (United States)

    Li, Xiang-Nong; Benjamin, IS; Alexander, B

    1998-01-01

    AIM: To produce a new rat model of portal hypertension by intraportal injection of microspheres. METHODS: Measured aliquots of single or different-sized microspheres (15, 40, 80μm) were injected into the portal vein to block intrahepatic portal radicals. The resultant changes in arterial,portal,hepatic venous and splenic pulp pressures were monitored. The liver and lungs were excised for histological examination. RESULTS: Portal venous pressure was elevated from basal value of 0.89-1.02 kPa to a steady-state of 1.98-3.19 kPa following the sequential injections of single- or different-sized microspheres, with a markedly lowered mean arterial pressure. However, a small-dose injection of 80 μm microspheres (1.8 × 105) produced a steady-state portal venous pressure of 2.53 × 0.17 kPa, and all rats showed normal arterial pressures. In addition, numerous microspheres were found in the lungs in all experimental groups. CONCLUSION: Portal hypertension can be reproduced in rats by intraportal injection of microspheres at a small dose of 80 μm (1.8 × 105). Intrahepatic portal-systemic shunts probably exist in the normal rat liver. PMID:11819236

  19. Verification of operating software for cooperative monitoring applications

    International Nuclear Information System (INIS)

    Tolk, K.M.; Rembold, R.K.

    1997-01-01

    Monitoring agencies often use computer based equipment to control instruments and to collect data at sites that are being monitored under international safeguards or other cooperative monitoring agreements. In order for this data to be used as an independent verification of data supplied by the host at the facility, the software used must be trusted by the monitoring agency. The monitoring party must be sure that the software has not be altered to give results that could lead to erroneous conclusions about nuclear materials inventories or other operating conditions at the site. The host might also want to verify that the software being used is the software that has been previously inspected in order to be assured that only data that is allowed under the agreement is being collected. A description of a method to provide this verification using keyed has functions and how the proposed method overcomes possible vulnerabilities in methods currently in use such as loading the software from trusted disks is presented. The use of public key data authentication for this purpose is also discussed

  20. The approach to engineering tasks composition on knowledge portals

    Science.gov (United States)

    Novogrudska, Rina; Globa, Larysa; Schill, Alexsander; Romaniuk, Ryszard; Wójcik, Waldemar; Karnakova, Gaini; Kalizhanova, Aliya

    2017-08-01

    The paper presents an approach to engineering tasks composition on engineering knowledge portals. The specific features of engineering tasks are highlighted, their analysis makes the basis for partial engineering tasks integration. The formal algebraic system for engineering tasks composition is proposed, allowing to set the context-independent formal structures for engineering tasks elements' description. The method of engineering tasks composition is developed that allows to integrate partial calculation tasks into general calculation tasks on engineering portals, performed on user request demand. The real world scenario «Calculation of the strength for the power components of magnetic systems» is represented, approving the applicability and efficiency of proposed approach.

  1. Earth Science Community IT Resources through a Unified Data and Analysis Portal

    Science.gov (United States)

    Bock, Y.; Webb, F. H.; Kedar, S.; Pierce, M.; Scharber, M.; Argus, D. F.; Aydin, G.; Chang, R.; Dong, D.; Fang, P.; Granat, R. A.; Jamason, P.; Newport, B. J.; Owen, S. E.; Parker, J. W.; Prawirodirdjo, L.; Vernon, F.; Wadsworth, G.

    2006-12-01

    We are in the process of merging the capabilities of three NASA-funded projects under the umbrella of the NASA Access Project, "Modeling and On-the-fly Solutions for Solid Earth Sciences (MOSES)" to facilitate data mining and modeling of rapidly expanding multi-disciplinary geoscience data sets. (1) The SCIGN- REASoN project is focused on the combination, validation, archive, and delivery of high-level data products and data mining capabilities from space geodetic measurements, in particular from over 600 CGPS stations in Western North America; (2) The QuakeSim project is developing linked Web service environments for supporting high performance models of crustal deformation from a variety of geophysical sensors, including GPS and seismic instruments; (3) The SENH-Applications GPS/Seismic integration project has developed a prototype real-time GPS/seismic displacement meter for seismic hazard mitigation and monitoring of critical infrastructure. The focus of the MOSES project is to enable direct interaction between modelers and data/data-product providers using Web services, within a unified portal architecture. Modeling applications include, for example, time series analysis of continuous and real-time data (e.g., RDAHMM and st_filter programs) and fault dislocation modeling (e.g., Simplex program). Community resources include access to extensive infrastructure and distributed data archive holdings, an on-line map server/client linked to a GIS database, a "GPS Explorer" data portal that is extensible to heterogeneous data sets, and "Geophysical Resource Web Services." We present the current capabilities of the unified data and analysis portal, and provide a few examples of combinations of independent geophysical measurements.

  2. Building an Archival Collections Portal

    Directory of Open Access Journals (Sweden)

    Stuart Marquis

    2008-06-01

    Full Text Available Columbia University Libraries has developed the Archival Collections Portal, a unified search system helping users discover archival resources in a streamlined way. We combined the power of Lucene and Solr to search XML, parse JSON objects, create EAD-compliant documents, and deliver results in an easy-to-use interface. By reusing MARC records and employing new search engine features and techniques, we are able to bring important and hard-to-find collections to researchers and archivists. The canonical home page of the Portal is http://www.columbia.edu/library/archival/.

  3. Application of real time spectrum measurement to radiation monitors

    International Nuclear Information System (INIS)

    Matsuno, K.; Watanabe, M.; Sakamaki, T.

    1996-01-01

    A multichannel analyzer (MCA) and two realtime spectrum monitoring methods have been developed for use in radiation monitors. The new MCA was designed to be installed at a local site as a component of a radiation monitor. The MCA repeats spectrum measurement at short intervals (Δt) and, after each measurement, transmits a spectrum datum to the operation console. The authors applied two methods to process Δt spectrum counts for each channel for longer time interval. One method of processing counts is the 'running average (RA) method'. The other method is the 'exponential smoothing (ES) method', which simulates RC rate meters by subtracting a fraction corresponding to the accumulated counts. Relative standard deviations for each channel can be made the same by selecting an appropriate value. The response with the 'ES' method is initially faster than that with the 'RA' method, but the 'RA' method allows a full response to be reached at a predictable time. (author)

  4. Application of fatigue monitoring system in PWR nuclear power plant

    International Nuclear Information System (INIS)

    Piao Lei

    2014-01-01

    Fatigue failure is one form of equipment failure of nuclear power plant, influencing equipment lifetime and lifetime extension. Fatigue monitoring system can track real thermal transient at fatigue sensitive components, establish a basis for fatigue analyses based on realistic operating loads, identify unexpected operational transients, optimize the plant behavior by improved operating modes, provide supporting data for lifetime management, enhance security of plant and reduce economical loss. Fatigue monitoring system has been applied in many plants and is required to be applied in Generation-III nuclear power plant. It is necessary to develop the fatigue monitoring system with independent intellectual property rights and improve the competitiveness of domestic Generation-III nuclear power technology. (author)

  5. 29 CFR 785.24 - Principles noted in Portal-to-Portal Bulletin.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Principles noted in Portal-to-Portal Bulletin. 785.24 Section 785.24 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR... of Principles Preparatory and Concluding Activities § 785.24 Principles noted in Portal-to-Portal...

  6. ACCOUNTING INFORMATION INTEGRATION TROUGH AN ENTERPRISE PORTAL

    Directory of Open Access Journals (Sweden)

    Gianina RIZESCU

    2014-06-01

    Full Text Available If companies are lacking integrated enterprise software applications, or they simply do not use them on a large scale, accounting departments have to face lots of difficulties, concerning both the inflexibility in achieving good results and the limited possibility of communicating these results. Thus, most times, accounting departments are limited to generating predefined reports provided by a software application and the most they can do is export these reports into Microsoft Excel. Another cause which leads to late obtaining and publishing of accounting information is the lack of data from other departments and their corresponding software applications. That is why, in many enterprises, accounting data becomes irrelevant for the users. The main goal of this article is to show how accounting can benefit from an integrated software solution, namely an enterprise portal.

  7. Risk monitor riskangel for risk-informed applications in nuclear power plants

    International Nuclear Information System (INIS)

    Wang, Fang; Wang, Jiaqun; Wang, Jin; Li, Yazhou; Hu, Liqin; Wu, Yican

    2016-01-01

    Highlights: • A general risk monitor riskangel with high-speed cutsets generator engine. • Benchmarks of actual nuclear power plant (NPP) instantaneous risk models. • Applications in daily operation, maintenance plan and component out of service. - Abstract: This paper studied the requirements of risk monitor software and its applications as a plant specific risk monitor, which supports risk-informed configuration risk management for the two CANDU 6 units at the Third Qinshan nuclear power plant (TQNPP) in China. It also describes the regulatory prospective on risk-informed Probabilistic Safety Assessment (PSA) applications and the use of risk monitor at operating nuclear power plants, high level technical and functional requirements for the development of CANDU specific risk monitor software, and future development trends.

  8. Efficient color correction method for smartphone camera-based health monitoring application.

    Science.gov (United States)

    Duc Dang; Chae Ho Cho; Daeik Kim; Oh Seok Kwon; Jo Woon Chong

    2017-07-01

    Smartphone health monitoring applications are recently highlighted due to the rapid development of hardware and software performance of smartphones. However, color characteristics of images captured by different smartphone models are dissimilar each other and this difference may give non-identical health monitoring results when the smartphone health monitoring applications monitor physiological information using their embedded smartphone cameras. In this paper, we investigate the differences in color properties of the captured images from different smartphone models and apply a color correction method to adjust dissimilar color values obtained from different smartphone cameras. Experimental results show that the color corrected images using the correction method provide much smaller color intensity errors compared to the images without correction. These results can be applied to enhance the consistency of smartphone camera-based health monitoring applications by reducing color intensity errors among the images obtained from different smartphones.

  9. Quantitative vs. subjective portal verification using digital portal images.

    Science.gov (United States)

    Bissett, R; Leszczynski, K; Loose, S; Boyko, S; Dunscombe, P

    1996-01-15

    Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamfer matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 degrees. For all four oncologists, the portals classified

  10. APPLICATION OF JET REMPI AND LIBS TO AIR TOXIC MONITORING

    Science.gov (United States)

    The paper discusses three advanced, laser-based monitoring techniques that the EPA is assisting in developing for real time measurement of toxic aerosol compounds. One of the three techniques is jet resonance enhanced multiphoton ionization (Jet REMPI) coupled with a time-of-flig...

  11. A Flexible Acoustic Sensor Network for Various Monitoring Applications

    NARCIS (Netherlands)

    Basten, T.G.H.; Wessels, P.W.

    2013-01-01

    Acoustic monitoring using a sensor network is a powerful instrument to assess and manage complex noise situations. It can provide a basis to identify appropriate and cost effective measures, and to assess their effect by comparing before and after implementation. It can also be an instrument for

  12. Single-chip microcomputer application in nuclear radiation monitoring instruments

    International Nuclear Information System (INIS)

    Zhang Songshou

    1994-01-01

    The single-chip microcomputer has advantage in many respects i.e. multiple function, small size, low-power consumption,reliability etc. It is widely used now in industry, instrumentation, communication and machinery. The author introduced usage of single-chip microcomputer in nuclear radiation monitoring instruments for control, linear compensation, calculation, changeable parameter presetting and military training

  13. Application of effective variance method for contamination monitor calibration

    International Nuclear Information System (INIS)

    Goncalez, O.L.; Freitas, I.S.M. de.

    1990-01-01

    In this report, the calibration of a thin window Geiger-Muller type monitor for alpha superficial contamination is presented. The calibration curve is obtained by the method of the least-squares fitting with effective variance. The method and the approach for the calculation are briefly discussed. (author)

  14. Portable Mass Spectrometer Applications for In Situ Environmental Gas Monitoring

    Science.gov (United States)

    Griffin, Timothy P.; Diaz, J. Andres; Arkin, C. Richard; Conejo, Elian

    2005-01-01

    Primary Goal of this project is to (1) Design/build a flexible system to monitor air contamination (2) Learn requirements for operating system in low pressure and low temperature environments (3) Design/build system for integration into aircraft and automobiles Secondary Goals/Offshoots are (1) Fly aboard different aircraft (2)Hand-carry unit (3) Drive unit in automobiles.

  15. Applicability of structured telephone monitoring to follow up heart ...

    African Journals Online (AJOL)

    Over 90% of the contacted patients gave valuable information regarding their clinical status. Conclusion: Majority of HF patients can be contacted and provide valuable clinical information through mobile phones within a month post discharge from the national hospital in Tanzania. Structured telephone monitoring could be ...

  16. Applicability of structured telephone monitoring to follow up heart ...

    African Journals Online (AJOL)

    Pilly Chillo

    Keywords: heart failure, structured telephone, home monitoring, Tanzania ... in a parallel increase in HF admissions and a major impact on health care systems. ... was entered in Statistical Package for Social Sciences (SPSS) version 20 software for analysis. ..... Failure (DIAL): study design and preliminary observations.

  17. Advances in statistical monitoring of complex multivariate processes with applications in industrial process control

    CERN Document Server

    Kruger, Uwe

    2012-01-01

    The development and application of multivariate statistical techniques in process monitoring has gained substantial interest over the past two decades in academia and industry alike.  Initially developed for monitoring and fault diagnosis in complex systems, such techniques have been refined and applied in various engineering areas, for example mechanical and manufacturing, chemical, electrical and electronic, and power engineering.  The recipe for the tremendous interest in multivariate statistical techniques lies in its simplicity and adaptability for developing monitoring applica

  18. Application of the No Action Level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers

    International Nuclear Information System (INIS)

    Boer, Hans C.J. de; Os, Marjolein J.H. van; Jansen, Peter P.; Heijmen, Ben J.M.

    2005-01-01

    Purpose: To evaluate the efficacy of the No Action Level (NAL) off-line correction protocol in the reduction of systematic prostate displacements as determined from electronic portal images (EPI) using implanted markers. Methods and materials: Four platinum markers, two near the apex and two near the base of the prostate, were implanted for localization purposes in patients who received fractionated high dose rate brachytherapy. During the following course of 25 fractions of external beam radiotherapy, the position of each marker relative to the corresponding position in digitally reconstructed radiographs (DRRs) was measured in EPI in 15 patients for on average 17 fractions per patient. These marker positions yield the composite displacements due to both setup error and internal prostate motion, relative to the planning computed tomography scan. As the NAL protocol is highly effective in reducing systematic errors (recurring each fraction) due to setup inaccuracy alone, we investigated its efficacy in reducing systematic composite displacements. The analysis was performed for the center of mass (COM) of the four markers, as well as for the cranial and caudal markers separately. Furthermore, the impact of prostate rotation on the achieved positioning accuracy was determined. Results: In case of no setup corrections, the standard deviations of the systematic composite displacements of the COM were 3-4 mm in the craniocaudal and anterior-posterior directions, and 2 mm in the left-right direction. The corresponding SDs of the random displacements (interfraction fluctuations) were 2-3 mm in each direction. When applying a NAL protocol based on three initial treatment fractions, the SDs of the systematic COM displacements were reduced to 1-2 mm. Displacements at the cranial end of the prostate were slightly larger than at the caudal end, and quantitative analysis showed this originates from left-right axis rotations about the prostate apex. Further analysis revealed

  19. Application of maximum radiation exposure values and monitoring of radiation exposure

    International Nuclear Information System (INIS)

    1996-01-01

    The guide presents the principles to be applied in calculating the equivalent dose and the effective dose, instructions on application of the maximum values for radiation exposure, and instruction on monitoring of radiation exposure. In addition, the measurable quantities to be used in monitoring the radiation exposure are presented. (2 refs.)

  20. Launch of Village Blue Web Application Shares Water Monitoring Data with Baltimore Community

    Science.gov (United States)

    EPA and the U.S. Geological Survey (USGS) have launched their mobile-friendly web application for Village Blue, a project that provides real-time water quality monitoring data to the Baltimore, Maryland community.

  1. AppMon: Application Monitors for Not-Yet-Trusted Software

    National Research Council Canada - National Science Library

    Marceau, Carla; Kozen, Dexter

    2007-01-01

    Report developed under STTR contract for topic OSD06-SP2. AppMon represents a novel approach to monitoring the behavior of not-yet-trusted applications that avoids the disadvantages of current approaches...

  2. Rapid monitoring particulate radiocesium with nonwoven fabric cartridge filter and application to field monitoring

    International Nuclear Information System (INIS)

    Tsuji, Hideki; Yasutaka, Tetsuo; Kondo, Yoshihiko; Kawashima, Shoji

    2013-01-01

    A method for rapid monitoring particulate radiocesium using a nonwoven fabric cartridge filter was developed, which needs no further preprocessing before served to a detector. By a performance test, more than 98% of suspended solid (SS) was collected. This method showed the same radioactivity measurement accuracy as filtration by membrane filter and more rapid extraction capability of SS. (author)

  3. General Purpose Data-Driven Online System Health Monitoring with Applications to Space Operations

    Science.gov (United States)

    Iverson, David L.; Spirkovska, Lilly; Schwabacher, Mark

    2010-01-01

    Modern space transportation and ground support system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional parameter limit checking, or model-based or rule-based methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults, failures, or precursors of significant failures. The Inductive Monitoring System (IMS) is a general purpose, data-driven system health monitoring software tool that has been successfully applied to several aerospace applications and is under evaluation for anomaly detection in vehicle and ground equipment for next generation launch systems. After an introduction to IMS application development, we discuss these NASA online monitoring applications, including the integration of IMS with complementary model-based and rule-based methods. Although the examples presented in this paper are from space operations applications, IMS is a general-purpose health-monitoring tool that is also applicable to power generation and transmission system monitoring.

  4. Model My Watershed and BiG CZ Data Portal: Interactive geospatial analysis and hydrological modeling web applications that leverage the Amazon cloud for scientists, resource managers and students

    Science.gov (United States)

    Aufdenkampe, A. K.; Mayorga, E.; Tarboton, D. G.; Sazib, N. S.; Horsburgh, J. S.; Cheetham, R.

    2016-12-01

    The Model My Watershed Web app (http://wikiwatershed.org/model/) was designed to enable citizens, conservation practitioners, municipal decision-makers, educators, and students to interactively select any area of interest anywhere in the continental USA to: (1) analyze real land use and soil data for that area; (2) model stormwater runoff and water-quality outcomes; and (3) compare how different conservation or development scenarios could modify runoff and water quality. The BiG CZ Data Portal is a web application for scientists for intuitive, high-performance map-based discovery, visualization, access and publication of diverse earth and environmental science data via a map-based interface that simultaneously performs geospatial analysis of selected GIS and satellite raster data for a selected area of interest. The two web applications share a common codebase (https://github.com/WikiWatershed and https://github.com/big-cz), high performance geospatial analysis engine (http://geotrellis.io/ and https://github.com/geotrellis) and deployment on the Amazon Web Services (AWS) cloud cyberinfrastructure. Users can use "on-the-fly" rapid watershed delineation over the national elevation model to select their watershed or catchment of interest. The two web applications also share the goal of enabling the scientists, resource managers and students alike to share data, analyses and model results. We will present these functioning web applications and their potential to substantially lower the bar for studying and understanding our water resources. We will also present work in progress, including a prototype system for enabling citizen-scientists to register open-source sensor stations (http://envirodiy.org/mayfly/) to stream data into these systems, so that they can be reshared using Water One Flow web services.

  5. Radiologic investigation of portal hypertension

    International Nuclear Information System (INIS)

    Becker, C.; Wegmueller, H.

    1993-01-01

    Radiologic evaluation of patients with portal hypertension in the pre- and postoperative period can be done with several non-invasive or invasive imaging modalities which offer complementary information. Doppler-ultrasonography (-US) is the method of choice for initial non-invasive screening as well as for follow-up tests after shunt surgery. The diagnostic information provided by Doppler-US regarding morphology and blood flow in the upper abdominal organs and vessels is sufficient in many instances. Dynamic computed tomography (CT), magnetic resonance tomography (MRT) and recently, magnetic resonance angiography (MRA) are additional non-invasive imaging techniques that may add valuable information if necessary. Conventional angiography is usually performed immediately prior to surgery to demonstrate the vascular morphology. The standard angiographic technique to demonstrate both the arterial and portal venous system is arterioportography (late-phase portography) by means of selective catheterization of the celiac, the splenic, the superior mesenteric or inferior mesenteric arteries. The dose of iodinated contrast material may be reduced by 50% if digital subtraction angiography is used instead of the conventional technique. Inferior venacavography and hepatic venography are indicated in patients with suspected postsinusoidal portal hypertension, e.g. the Budd-Chiari syndrome; hepatic wedge manometry offers valuable information regarding pressure gradients between the portal and systemic venous system prior to shunt surgery. The angiographic access through the inferior vena cava is also used for direct catheterization of surgical porto-caval or spleno-renal shunts for both angiography, manometry and, if necessary, balloon angioplasty. (authors)

  6. Supplemental Report: Application of Emission Spectroscopy to Monitoring Technetium

    International Nuclear Information System (INIS)

    Spencer, W.A.

    2000-01-01

    This report provides supplemental information to an earlier report BNF-98-003-0199, ''Evaluation of Emission Spectroscopy for the On-Line Analysis of Technetium''. In this report data is included from real Hanford samples as well as for solutions spiked with technetium. This supplemental work confirms the ability of ICP-ES to monitor technetium as it breaks through an ion exchange process

  7. Application of gamma-ray spectroscopy in environmental monitoring

    International Nuclear Information System (INIS)

    Hobbs, B.B.; Kanipe, L.G.; Clayton, W.R.; Belvin, E.A.

    1976-01-01

    Gamma-ray spectroscopy is used as the primary analytical method in the Tennessee Valley Authority's environmental radiation monitoring program. Routine sample screening is done by means of least-squares analysis of spectra from NaI(Tl) detectors. Nonroutine or suspicious samples are analyzed by means of Ge(Li) spectral analysis. A laboratory quality control program provides internal and external checks on the reliability of analyses

  8. Application of ubiquitous computing in personal health monitoring systems.

    Science.gov (United States)

    Kunze, C; Grossmann, U; Stork, W; Müller-Glaser, K D

    2002-01-01

    A possibility to significantly reduce the costs of public health systems is to increasingly use information technology. The Laboratory for Information Processing Technology (ITIV) at the University of Karlsruhe is developing a personal health monitoring system, which should improve health care and at the same time reduce costs by combining micro-technological smart sensors with personalized, mobile computing systems. In this paper we present how ubiquitous computing theory can be applied in the health-care domain.

  9. Nonparametric Integrated Agrometeorological Drought Monitoring: Model Development and Application

    Science.gov (United States)

    Zhang, Qiang; Li, Qin; Singh, Vijay P.; Shi, Peijun; Huang, Qingzhong; Sun, Peng

    2018-01-01

    Drought is a major natural hazard that has massive impacts on the society. How to monitor drought is critical for its mitigation and early warning. This study proposed a modified version of the multivariate standardized drought index (MSDI) based on precipitation, evapotranspiration, and soil moisture, i.e., modified multivariate standardized drought index (MMSDI). This study also used nonparametric joint probability distribution analysis. Comparisons were done between standardized precipitation evapotranspiration index (SPEI), standardized soil moisture index (SSMI), MSDI, and MMSDI, and real-world observed drought regimes. Results indicated that MMSDI detected droughts that SPEI and/or SSMI failed to do. Also, MMSDI detected almost all droughts that were identified by SPEI and SSMI. Further, droughts detected by MMSDI were similar to real-world observed droughts in terms of drought intensity and drought-affected area. When compared to MMSDI, MSDI has the potential to overestimate drought intensity and drought-affected area across China, which should be attributed to exclusion of the evapotranspiration components from estimation of drought intensity. Therefore, MMSDI is proposed for drought monitoring that can detect agrometeorological droughts. Results of this study provide a framework for integrated drought monitoring in other regions of the world and can help to develop drought mitigation.

  10. Radionuclide hepatic perfusion index and ultrasonography: Assessment of portal hypertension in clinical practice

    International Nuclear Information System (INIS)

    Seidlova, V.; Hobza, J.; Pumprla, J.; Charouzek, J.

    1989-01-01

    The application is described of radionuclide angiography with hepatic perfusion index (HPI) determination in diagnosis of portal blood flow as an indicator of portal hypertension. 99m Tc and 113 In were used as tracers. Over forty patients suffering from chronic hepatitis or liver cirrhosis were included in the study. Ultrasound was used as a preliminary rapid diagnosis of portal hypertension. Radionuclide angiography combined with the HPI technique was confirmed to be a beneficial noninvasive method offering reproducible quantitative information on portal flow well correlating with the degree of portal hypertension, while the combination of ultrasound examination with radionuclide HPI determination appears to greatly enrich the diagnostic potential in hepatology. (L.O.). 4 figs., 11 refs

  11. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  12. APPLICATIONS OF CURRENT TECHNOLOGY FOR CONTINUOUS MONITORING OF SPENT FUEL

    Energy Technology Data Exchange (ETDEWEB)

    Drayer, R.

    2013-06-09

    Advancements in technology have opened many opportunities to improve upon the current infrastructure surrounding the nuclear fuel cycle. Embedded devices, very small sensors, and wireless technology can be applied to Security, Safety, and Nonproliferation of Spent Nuclear Fuel. Security, separate of current video monitoring systems, can be improved by integrating current wireless technology with a variety of sensors including motion detection, altimeter, accelerometer, and a tagging system. By continually monitoring these sensors, thresholds can be set to sense deviations from nominal values. Then alarms or notifications can be activated as needed. Safety can be improved in several ways. First, human exposure to ionizing radiation can be reduced by using a wireless sensor package on each spent fuel cask to monitor radiation, temperature, humidity, etc. Since the sensor data is monitored remotely operator stay-time is decreased and distance from the spent fuel increased, so the overall radiation exposure is reduced as compared to visual inspections. The second improvement is the ability to monitor continuously rather than periodically. If changes occur to the material, alarm thresholds could be set and notifications made to provide advanced notice of negative data trends. These sensor packages could also record data to be used for scientific evaluation and studies to improve transportation and storage safety. Nonproliferation can be improved for spent fuel transportation and storage by designing an integrated tag that uses current infrastructure for reporting and in an event; tracking can be accomplished using the Iridium satellite system. This technology is similar to GPS but with higher signal strength and penetration power, but lower accuracy. A sensor package can integrate all or some of the above depending on the transportation and storage requirements and regulations. A sensor package can be developed using off the shelf technology and applying it to each

  13. Applications of current technology for continuous monitoring of spent fuel

    International Nuclear Information System (INIS)

    Drayer, R.

    2013-01-01

    Advancements in technology have opened many opportunities to improve upon the current infrastructure surrounding the nuclear fuel cycle. Embedded devices, very small sensors, and wireless technology can be applied to Security, Safety, and Nonproliferation of Spent Nuclear Fuel. Security, separate of current video monitoring systems, can be improved by integrating current wireless technology with a variety of sensors including motion detection, altimeter, accelerometer, and a tagging system. By continually monitoring these sensors, thresholds can be set to sense deviations from nominal values. Then alarms or notifications can be activated as needed. Safety can be improved in several ways. First, human exposure to ionizing radiation can be reduced by using a wireless sensor package on each spent fuel cask to monitor radiation, temperature, humidity, etc. Since the sensor data is monitored remotely operator stay-time is decreased and distance from the spent fuel increased, so the overall radiation exposure is reduced as compared to visual inspections. The second improvement is the ability to monitor continuously rather than periodically. If changes occur to the material, alarm thresholds could be set and notifications made to provide advanced notice of negative data trends. These sensor packages could also record data to be used for scientific evaluation and studies to improve transportation and storage safety. Nonproliferation can be improved for spent fuel transportation and storage by designing an integrated tag that uses current infrastructure for reporting and in an event; tracking can be accomplished using the Iridium satellite system. This technology is similar to GPS but with higher signal strength and penetration power, but lower accuracy. A sensor package can integrate all or some of the above depending on the transportation and storage requirements and regulations. A sensor package can be developed using off the shelf technology and applying it to each

  14. Strength monitoring of bridge constructions and features of its application. Part 1. International and domestic experience of monitoring application

    Directory of Open Access Journals (Sweden)

    Ovchinnikov Igor Georgievich

    2014-03-01

    Full Text Available The development trend of building systems can be characterized in the following words: sophistication of design and simplification of operation. And the main task of the engineering structure operation is to ensure stability of the functioning structures with respect to the external aggressive impacts. The article considers the strength monitoring of bridge structures proposed by Ovchinnikov I.G. in 1994. The strength monitoring is an element of the engineering structure operation system. Algorithm of structure monitoring is based on the following main tasks — establishing nature of the external impacts on the structure and evaluating capacity of structure to resist these impacts in the concrete environment of operation. The article considers the different approaches to solving problem of transport structure operation around the world. It is proposed to include the following subsystems in the system of structure operation: 1 a subsystem of the strength monitoring of structures; 2 a subsystem of the scientific research and development organization; 3 a subsystem of work automation on the structure status management; 4 a subsystem of personnel training for work in the system of structure operation, including monitoring, research, automation of works, emergency response and quality management; 5 a subsystem of actions in the case of emergencies; 6 a subsystem of the quality management of structure operation and 7 a subsystem of ecological structure monitoring. It is noted that at the stage of structure operation the active monitoring includes the solution of the following main tasks: 1 evaluation of the stress — strain state of construction components and the whole structure, as well as the kinetics of its change taking into account the existing defects and damages of local and distributed type; 2 analysis and evaluation of degree of conformity for the ultimate load-carrying capacity of structure to the external impacts during the moment under

  15. Distributed applications monitoring at system and network level

    CERN Document Server

    Aderholz, Michael; Augé, E; Bagliesi, G; Banistoni, G; Barone, L; Boschini, M; Brunengo, A; Bunn, J J; Butler, J; Campanella, M; Capiluppi, P; D'Amato, M; Darneri, M; Di Mattia, A; Dorokhov, A E; Gagliardi, F; Gaines, I; Gasparini, U; Ghiselli, A; Gordon, J; Grandi, C; Gálvez, P; Harris, F; Holtman, K; Karimäki, V; Karita, Y; Klem, J T; Legrand, I; Leltchouk, M; Linglin, D; Lubrano, P; Luminari, L; McArthur, I C; Michelotto, M; Morita, Y; Nazarenko, A; Newman, H; O'Dell, Vivian; O'Neale, S W; Osculati, B; Pepé, M; Perini, L; Pinfold, James L; Pordes, R; Prelz, F; Putzer, A; Resconi, S; Robertson, L; Rolli, S; Sasaki, T; Sato, H; Schaffer, R D; Schalk, T L; Servoli, L; Sgaravatto, M; Shiers, J; Silvestris, L; Siroli, G P; Sliwa, K; Smith, T; Somigliana, R; Stanescu, C; Stockinger, H E; Ugolotti, D; Valente, E; Vistoli, C; Wilkinson, R P; Willers, Ian Malcolm; Williams, D O

    2001-01-01

    Most distributed applications are based on architectural models that do not involve real-time knowledge of network status and of their network usage. Moreover the new "network aware" architectures are still under development and their design is not yet complete. We considered, as a use case, an application using ODBMS (Objectivity /DB) for the distributed analysis of experimental data. The dynamic usage of system and network resources at host and application levels has been measured in different client/server configurations, and on several LAN and WAN layouts. The aim was to study the application efficiency and behavior versus the network characteristics and conditions. The most interesting results of the LAN and WAN tests are described. System bottlenecks and limitations have been identified, and efficient working conditions in the different scenarios have been defined. The behavior observed when moving away from the optimal working conditions is also described.

  16. Intelligent interaction based on holographic personalized portal

    Directory of Open Access Journals (Sweden)

    Yadong Huang

    2017-06-01

    Full Text Available Purpose – The purpose of this paper is to study the architecture of holographic personalized portal, user modeling, commodity modeling and intelligent interaction. Design/methodology/approach – In this paper, the authors propose crowd-science industrial ecological system based on holographic personalized portal and its interaction. The holographic personality portal is based on holographic enterprises, commodities and consumers, and the personalized portal consists of accurate ontology, reliable supply, intelligent demand and smart cyberspace. Findings – The personalized portal can realize the information acquisition, characteristic analysis and holographic presentation. Then, the intelligent interaction, e.g. demand decomposition, personalized search, personalized presentation and demand prediction, will be implemented within the personalized portal. Originality/value – The authors believe that their work on intelligent interaction based on holographic personalized portal, which has been first proposed in this paper, is innovation focusing on the interaction between intelligence and convenience.

  17. Application of microwave radiometers for wetlands and estuaries monitoring

    International Nuclear Information System (INIS)

    Shutko, A.; Haldin, A.; Novichikhin, E.

    1997-01-01

    This paper presents the examples of experimental data obtained with airborne microwave radiometers used for monitoring of wetlands and estuaries located in coastal environments. The international team of researchers has successfully worked in Russia, Ukraine and USA. The data presented relate to a period of time between 1990 and 1995. They have been collected in Odessa Region, Black Sea coast, Ukraine, in Regions of Pittsville and Winfield, Maryland, USA, and in Region of St. Marks, Florida, USA. The parameters discussed are a soil moisture, depth to a shallow water table, vegetation index, salinity of water surface

  18. Development and application of the San Onofre safety monitor

    International Nuclear Information System (INIS)

    Hook, Thomas G.; Lee, Roger J.; Morgan, Thomas A.

    2004-01-01

    Halliburton NUS Corporation (NUS) has developed a risk-based configuration management software tool for use at Southern California Edison's San Onofre Nuclear Generating Station. The software, called the Safety Monitor, calculates an estimate of current plant core damage risk based upon the plant's current operating configuration (e.g., equipment operability, system operating alignments). All data is entered and displayed in a format easily understood by plant personnel. The plant hopes to use this tool to ensure that risk is minimized during plant operations and to identify situations in which current Technical Specifications can be optimized. Plant configuration data and out-of-service time data is also automatically collected. (author)

  19. On-line monitoring applications at nuclear power plants. A risk informed approach to calibration reduction

    International Nuclear Information System (INIS)

    Shankar, Ramesh; Hussey, Aaron; Davis, Eddie

    2003-01-01

    On-line monitoring of instrument channels provides increased information about the condition of monitored channels through accurate, more frequent evaluation of each cannel's performance over time. This type of performance monitoring is a methodology that offers an alternate approach to traditional time-directed calibration. EPRI's strategic role in on-line monitoring is to facilitate its implementation and cost-effective use in numerous applications at power plants. To this end, EPRI has sponsored an on-line monitoring implementation project at multiple nuclear plants specifically intended to install and use on-line monitoring technology. The selected on-line monitoring method is based on the Multivariate State Estimation Technique. The project has a planned three-year life; seven plants are participating in the project. The goal is to apply on-line monitoring to all types of power plant applications and document all aspects of the implementation process in a series of EPRI reports. These deliverables cover installation, modeling, optimization, and proven cost-benefit. This paper discusses the actual implementation of on-line monitoring to various nuclear plant instrument systems. Examples of detected instrument drift are provided. (author)

  20. Application of near field communication for health monitoring in daily life.

    Science.gov (United States)

    Strömmer, Esko; Kaartinen, Jouni; Pärkkä, Juha; Ylisaukko-Oja, Arto; Korhonen, Ilkka

    2006-01-01

    We study the possibility of applying an emerging RFID-based communication technology, NFC (Near Field Communication), to health monitoring. We suggest that NFC is, compared to other competing technologies, a high-potential technology for short-range connectivity between health monitoring devices and mobile terminals. We propose practices to apply NFC to some health monitoring applications and study the benefits that are attainable with NFC. We compare NFC to other short-range communication technologies such as Bluetooth and IrDA, and study the possibility of improving the usability of health monitoring devices with NFC. We also introduce a research platform for technical evaluation, applicability study and application demonstrations of NFC.

  1. The BAOBAB data portal and DACCIWA database

    Science.gov (United States)

    Brissebrat, Guillaume; Belmahfoud, Nizar; Cloché, Sophie; Ferré, Hélène; Fleury, Laurence; Mière, Arnaud; Ramage, Karim

    2017-04-01

    In the framework of the African Monsoon Multidisciplinary Analyses (AMMA) programme, several tools have been developed in order to boost the data and information exchange between researchers from different disciplines: a user-friendly data management and dissemination system, quasi real-time display websites and a scientific paper exchange collaborative tool. The information system is enriched by past and ongoing projects (IMPETUS, FENNEC, ESCAPE, QweCI, ACASIS, DACCIWA...) addressing meteorology, atmospheric chemistry, hydrology, extreme events, health, adaptation of human societies... It is becoming a reference information system on environmental issues in West Africa: BAOBAB (Base Afrique de l'Ouest beyond AMMA Base). The projects include airborne, ground-based and ocean measurements, social science surveys, satellite data use, modelling studies and value-added product development. Therefore, the BAOBAB data portal enables to access a great amount and a large variety of data: - 250 local observation datasets, that have been collected by operational networks since 1850, long term monitoring research networks and intensive scientific campaigns; - 1350 outputs of a socio-economics questionnaire; - 60 operational satellite products and several research products; - 10 output sets of meteorological and ocean operational models and 15 of research simulations. Data documentation complies with metadata international standards, and data are delivered into standard formats. The data request interface takes full advantage of the database relational structure and enables users to elaborate multicriteria requests (period, area, property…). The BAOBAB data portal counts about 900 registered users, and 50 data requests every month. The databases and data portal have been developed and are operated jointly by SEDOO and ESPRI in France: http://baoab.sedoo.fr. The ongoing DACCIWA (Dynamics-Aerosol-Chemistry-Cloud Interactions over West Africa) project uses the BAOBAB portal to

  2. Amperometric and impedance monitoring systems for biomedical applications

    CERN Document Server

    Punter-Villagrasa, Jaime; del Campo, Francisco J; Miribel, Pere

    2017-01-01

    The book presents the conception and realization of a pervasive electronic architecture for electrochemical applications, focusing on electronic instrumentation design and device development, particularly in electrochemical Point-of-Care and Lab-on-a-Chip devices, covering examples based on amperometric (DC) and impedance detection (AC) techniques. The presented electronics combine tailored front-end instrumentation and back-end data post-processing, enabling applications in different areas, and across a variety of techniques, analytes, transducers and environments. It addresses how the electronics are designed and implemented with special interest in the flow process: starting from electronic circuits and electrochemical biosensor design to a final validation and implementation for specific applications. Similarly, other important aspects are discussed throughout the book, such as electrochemical techniques, different analytes, targets, electronics reliability and robustness. The book also describes the use ...

  3. Nanobarcode gene expression monitoring system for potential miniaturized space applications

    Science.gov (United States)

    Ruan, Weiming; Eastman, P. Scott; Cooke, Patrick A.; Park, Jennifer S.; Chu, Julia S. F.; Gray, Joe W.; Li, Song; Chen, Fanqing Frank

    Manned mission to space has been threatened by various cosmos risks including radiation, mirogravity, vacuum, confinement, etc., which may cause genetic variations of astronauts and eventually lead to damages of their health. Thus, the development of small biomedical devices, which can monitor astronaut gene expression changes, is useful for future long-term space missions. Using magnetic microbeads packed with nanocrystal quantum dots at controlled ratios, we were able to generate highly multiplexed nanobarcodes, which can encode a flexible panel of genes. Also, by using a reporter quantum dot, this nanobarcode platform can monitor and quantify gene expression level with improved speed and sensitivity. As a comparison, we studied TGF-β1 induced transcription changes in human bone marrow mesenchymal stem cells with both the nanobarcode microbead system and the Affymetrix GeneChip ® HTA system, which is currently considered as the industrial standard. Though using only 1/20 of the sample RNA, the nanobarcode system showed sensitivity equivalent to Affymetrix GeneChip ® system. The coefficient of variation, dynamic range, and accuracy of the nanobarcodes measurement is equivalent to that of the GeneChip ® HTA system. Therefore, this newly invented nanobarcode microbead platform is thought to be sensitive, flexible, cost-effective and accurate in a level equivalent to the conventional methods. As an extension of the use of this new platform, spacecrafts may carry this miniaturized system as a diagnostic tool for the astronauts.

  4. Application of diamond based beam loss monitors at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Hempel, Maria

    2013-04-15

    The Large Hadron Collider (LHC) was conceived in the 1980s and started the operation in 2008. It needed more than 20 years to plan and construct this accelerator and its experiments. Four main experiments are located around the ring, Compact Muon Solenoid (CMS), A Toroidal LHC Apparatus(ATLAS), A Large Ion Collider Experiment (ALICE) and LHC beauty (LHCb). Two beams that traveling in opposite direction in the LHC tunnel, collide in each of the experiments to study the questions: ''What is mass?'', ''What is the universe made of?'' and ''Why is there no antimatter?''. The four experiments take data of the collision products and try to answer the fundamental questions of physics. The two larger detectors, CMS and ATLAS, are looking for the Higgs boson to study the electroweak symmetry breaking. Both detectors were built with contrasting concepts to exclude potential error sources and to rea rm the results. The smaller experiment LHCb studies the matter-antimatter asymmetry with a focus of the beauty quark. Another smaller experiment is ALICE that studies the conditions right after the Big Bang by colliding heavy ions. The navigation of the beams is done by over 10000 magnets and each beam has a stored energy of 362MJ which correspond to the kinetic energy of a train like the TGV travelling of 150 km/h. Only a small percentage of that energy can damage the material in the LHC ring or the magnets. This would mean a repair time of months or years, without taking any data. To avoid such a scenario, it is important to monitor the beam condition and measure the amount of losses of the beam. Such losses can for example happen due to dust particles in the vacuum chambers or due to deviations of the beam parameters. Several systems called beam loss monitors (BLMs) can measure beam losses. This thesis concentrates on two of them, ionization chambers and diamond detectors. Over 3600 ionization chambers are installed in

  5. Application of diamond based beam loss monitors at LHC

    International Nuclear Information System (INIS)

    Hempel, Maria

    2013-04-01

    The Large Hadron Collider (LHC) was conceived in the 1980s and started the operation in 2008. It needed more than 20 years to plan and construct this accelerator and its experiments. Four main experiments are located around the ring, Compact Muon Solenoid (CMS), A Toroidal LHC Apparatus(ATLAS), A Large Ion Collider Experiment (ALICE) and LHC beauty (LHCb). Two beams that traveling in opposite direction in the LHC tunnel, collide in each of the experiments to study the questions: ''What is mass?'', ''What is the universe made of?'' and ''Why is there no antimatter?''. The four experiments take data of the collision products and try to answer the fundamental questions of physics. The two larger detectors, CMS and ATLAS, are looking for the Higgs boson to study the electroweak symmetry breaking. Both detectors were built with contrasting concepts to exclude potential error sources and to rea rm the results. The smaller experiment LHCb studies the matter-antimatter asymmetry with a focus of the beauty quark. Another smaller experiment is ALICE that studies the conditions right after the Big Bang by colliding heavy ions. The navigation of the beams is done by over 10000 magnets and each beam has a stored energy of 362MJ which correspond to the kinetic energy of a train like the TGV travelling of 150 km/h. Only a small percentage of that energy can damage the material in the LHC ring or the magnets. This would mean a repair time of months or years, without taking any data. To avoid such a scenario, it is important to monitor the beam condition and measure the amount of losses of the beam. Such losses can for example happen due to dust particles in the vacuum chambers or due to deviations of the beam parameters. Several systems called beam loss monitors (BLMs) can measure beam losses. This thesis concentrates on two of them, ionization chambers and diamond detectors. Over 3600 ionization chambers are installed in the LHC, especially near each quadrupole and next to

  6. The GENIUS Grid Portal and robot certificates: a new tool for e-Science.

    Science.gov (United States)

    Barbera, Roberto; Donvito, Giacinto; Falzone, Alberto; La Rocca, Giuseppe; Milanesi, Luciano; Maggi, Giorgio Pietro; Vicario, Saverio

    2009-06-16

    Grid technology is the computing model which allows users to share a wide pletora of distributed computational resources regardless of their geographical location. Up to now, the high security policy requested in order to access distributed computing resources has been a rather big limiting factor when trying to broaden the usage of Grids into a wide community of users. Grid security is indeed based on the Public Key Infrastructure (PKI) of X.509 certificates and the procedure to get and manage those certificates is unfortunately not straightforward. A first step to make Grids more appealing for new users has recently been achieved with the adoption of robot certificates. Robot certificates have recently been introduced to perform automated tasks on Grids on behalf of users. They are extremely useful for instance to automate grid service monitoring, data processing production, distributed data collection systems. Basically these certificates can be used to identify a person responsible for an unattended service or process acting as client and/or server. Robot certificates can be installed on a smart card and used behind a portal by everyone interested in running the related applications in a Grid environment using a user-friendly graphic interface. In this work, the GENIUS Grid Portal, powered by EnginFrame, has been extended in order to support the new authentication based on the adoption of these robot certificates. The work carried out and reported in this manuscript is particularly relevant for all users who are not familiar with personal digital certificates and the technical aspects of the Grid Security Infrastructure (GSI). The valuable benefits introduced by robot certificates in e-Science can so be extended to users belonging to several scientific domains, providing an asset in raising Grid awareness to a wide number of potential users. The adoption of Grid portals extended with robot certificates, can really contribute to creating transparent access to

  7. Dynamic weighing for accurate fertilizer application and monitoring

    NARCIS (Netherlands)

    Bergeijk, van J.; Goense, D.; Willigenburg, van L.G.; Speelman, L.

    2001-01-01

    The mass flow of fertilizer spreaders must be calibrated for the different types of fertilizers used. To obtain accurate fertilizer application manual calibration of actual mass flow must be repeated frequently. Automatic calibration is possible by measurement of the actual mass flow, based on

  8. Intranet portal at the Krsko NPP, Slovenia

    International Nuclear Information System (INIS)

    2016-01-01

    The intranet portal (named IntraNEK) at Krsko NPP serves as a single entry point to access the internet and various plant applications and links. The front page consists of the standard internet search bar and links to various applications that can either reside within the technological computer network (TRM) or within the plant business computer network. Access to the TRM applications is read only. Some applications on the business computer network are open to all personnel who log on to the network while some applications are restricted and secured, and require additional login entries. A selected link will open in a new window. Documents will open with the appropriate software tool depending on the document file format. Some categories of documents are available in image form only (e.g. procedures, drawings etc.), while some are available in fully searchable PDF format (e.g. technical specifications, updated safety analysis reports (USARs) etc.). Plant departments (organizational units) have their own pages accessible from the front page. Their pages contain links to their own information resources or links to other resources and applications, tailored to the department needs. During recent years a number of web based applications have been developed that are connected also with a common Oracle database. Some are designed to serve for data entry and browsing while others serve for browsing only

  9. Applications of Piezoelectric Materials in Structural Health Monitoring and Repair: Selected Research Examples.

    Science.gov (United States)

    Duan, Wen Hui; Wang, Quan; Quek, Ser Tong

    2010-12-06

    The paper reviews the recent applications of piezoelectric materials in structural health monitoring and repair conducted by the authors. First, commonly used piezoelectric materials in structural health monitoring and structure repair are introduced. The analysis of plain piezoelectric sensors and actuators and interdigital transducer and their applications in beam, plate and pipe structures for damage detection are reviewed in detail. Second, an overview is presented on the recent advances in the applications of piezoelectric materials in structural repair. In addition, the basic principle and the current development of the technique are examined.

  10. Applications of Piezoelectric Materials in Structural Health Monitoring and Repair: Selected Research Examples

    Directory of Open Access Journals (Sweden)

    Ser Tong Quek

    2010-12-01

    Full Text Available The paper reviews the recent applications of piezoelectric materials in structural health monitoring and repair conducted by the authors. First, commonly used piezoelectric materials in structural health monitoring and structure repair are introduced. The analysis of plain piezoelectric sensors and actuators and interdigital transducer and their applications in beam, plate and pipe structures for damage detection are reviewed in detail. Second, an overview is presented on the recent advances in the applications of piezoelectric materials in structural repair. In addition, the basic principle and the current development of the technique are examined.

  11. VisPortal: Deploying grid-enabled visualization tools through a web-portal interface

    Energy Technology Data Exchange (ETDEWEB)

    Bethel, Wes; Siegerist, Cristina; Shalf, John; Shetty, Praveenkumar; Jankun-Kelly, T.J.; Kreylos, Oliver; Ma, Kwan-Liu

    2003-06-09

    The LBNL/NERSC Visportal effort explores ways to deliver advanced Remote/Distributed Visualization (RDV) capabilities through a Grid-enabled web-portal interface. The effort focuses on latency tolerant distributed visualization algorithms, GUI designs that are more appropriate for the capabilities of web interfaces, and refactoring parallel-distributed applications to work in a N-tiered component deployment strategy. Most importantly, our aim is to leverage commercially-supported technology as much as possible in order to create a deployable, supportable, and hence viable platform for delivering grid-based visualization services to collaboratory users.

  12. The SmartGeo Portal: A retrospective

    Science.gov (United States)

    Heilmann, Zeno; Satta, Guido; Bonomi, Ernesto

    2016-04-01

    The SmartGeo portal was created in a follow-up project that evolved from the geophysical data imaging services of a Grid computing portal for Geoscience, called GRIDA3. The scope of the project was to support commercial geotechnical service providers as well as academic researchers working in near-surface geoscience. Starting from the existing services, the SmartGeo portal was set up on new hardware, using the latest version of the grid portal environment EnginFrame. After a first working version was established, the services were reviewed, updated and accompanied by new services according to the feedback we received from our partners. One partner for instance experienced large difficulties in a project that aimed at delineating the aquifer for finding water pollutant substances in an industrial area of Basel. The seismic imaging service inherited from the previous portal was employing a data-driven algorithm optimized to provide, directly during data acquisition, nearly in real-time a first image of the subsurface structure. Different to this, our user needed for his data from a geologically very complex and noisy urban environment the maximum lateral resolution and noise reduction possible. For this purpose we added two cutting edge data imaging algorithms able to deliver such high precision results by simultaneously optimizing, for every single image point, all parameters of the mathematical model---a procedure which increased the computational effort by one or two magnitudes, respectively. Thus, parallel computing on grid infrastructure served for maximizing the image resolution instead for generating real-time results. This proved also very useful for the data of an academic partner, recorded for imaging the structure of a shallow sedimentary basin, where we could obtain strongly improved seismic velocity information using these new algorithms. A general user request was to implement interactive data visualization tools. To fulfill this demand we took

  13. Seasonal monitoring of Aedes albopictus: practical applications and outcomes

    Directory of Open Access Journals (Sweden)

    Stefano Gavaudan

    2014-06-01

    Full Text Available The introduction of the Asian tiger mosquito Aedes (Stegomya albopictus (Diptera: Culicidae into temperate regions poses serious concerns for the risk of the spreading of arboviral epidemics, as confirmed by the Chikungunya fever outbreak in Italy. This article describes the implementation and the results of a strategy for the pest management implemented over 4 years in Pesaro (a city in the Marche region, Italy. The strategy used 60 integrated wide‑sized ovitraps for monitoring purposes. Twenty-day larvicide-based treatment cycles were implemented for the manholes of the urban area and also the inhabitants were involved in pest control relating to their own properties. It was observed that the weekly median of eggs laid decreased consistently from 2008 to 2011, indicating the good performance of the vector control and a reduction in the related epidemics risk.

  14. Percutaneous angioplasty of portal vein stenosis that complicated liver transplantation: the mid-term therapeutic results

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Bo; Choo, Sung Wook; Do, Young Soo; Shin, Sung Wook; Cho, Sung Gi; Choo, In Wook [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2005-09-15

    We wanted to valuate the mid-term therapeutic results of percutaneous transhepatic balloon angioplasty for portal vein stenosis after liver transplantation. From May 1996 to Feb 2005, 420 patients underwent liver transplantation. Percutaneous transhepatic angioplasty of the portal vein was attempted in six patients. The patients presented with the clinical signs and symptoms of portal venous hypertension or they were identified by surveillance doppler ultrasonography. The preangioplasty and postangioplasty pressure gradients were recorded. The therapeutic results were monitored by the follow up of the clinical symptoms, the laboratory values, CT and ultrasonography. The overall technical success rate was 100%. The clinical success rate was 83% (5/6). A total of eight sessions of balloon angioplasty were performed in six patients. The mean pressure gradient decreased from 14.5 mmHg to 2.8 mmHg before and after treatment, respectively. The follow up periods ranged from three months to 64 months (mean period; 32 months). Portal venous patency was maintained in all six patients until the final follow up. Combined hepatic venous stenosis was seen in one patient who was treated with stent placement. One patient showed puncture tract bleeding, and this patient was treated with coil embolization of the right portal puncture tract via the left transhepatic portal venous approach. Percutaneous transhepatic balloon angioplasty is an effective treatment for the portal vein stenosis that occurs after liver transplantation, and our results showed good mid-term patency with using this technique.

  15. Corporate portal system at PAKS NPP, Hungary

    International Nuclear Information System (INIS)

    2009-01-01

    The new Corporate Portal System (CPS) of Paks NPP was launched in November 2006. The portal is based on one of the latest technologies, Plumtree Enterprise WEB 5.0. The main purpose of the installation of the new technology was to serve the working culture change, to give a platform to access all information and applications including the integrated process model used at the NPP. The new technology also supports those goals which were defined in the organization development programme: e.g. to improve internal communication with the establishment of communities of practice. Installation of the CPS has provided a powerful tool for knowledge management; it is possible to share and find all information through a controlled access in documents from various sources, to have links to people, portlets and different communities. Document management of the Paks NPP is supported by the integration of the Document 5 application, as the new Electronic Data Management System (EDMS) and the CPS. Depending on their access rights, all users of the CPS, through Microsoft Internet Explorer, can access technical, economic and human resources documents which are stored anywhere on the internal network (file servers, EDMS, old INRANET). The CPS is also accessible from the internet through a secure connection. The main concept is the integration of all applications to one platform and to help users to find all information they need. An access control list specifies which users and groups have access to an object (and what kind of access privileges they have such as read, select, edit, admin)

  16. NUCLEONICA: a nuclear science portal

    International Nuclear Information System (INIS)

    Magill, J.; Galy, J.; Dreher, R.; Hamilton, D.; Tufan, M.; Normand, C.; Schwenk-Ferrero, A.; Wiese, H.W.

    2008-01-01

    NUCLEONICA is a new nuclear science web portal from the European Commission's Joint Research Centre. The portal provides a customizable, integrated environment and collaboration platform for the nuclear sciences using the latest 'Web 2.0' dynamic technology. NUCLEONICA is aimed at professionals, academics and students working with radionuclides in fields as diverse as the life sciences (e.g., biology, medicine, agriculture), the earth sciences (geology, meteorology, environmental science) and the more traditional disciplines such as nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. It is also used as a knowledge management tool to preserve nuclear knowledge built up over many decades by creating modern web-based versions of so-called legacy computer codes. (authors)

  17. The secondary metabolite bioinformatics portal

    DEFF Research Database (Denmark)

    Weber, Tilmann; Kim, Hyun Uk

    2016-01-01

    . In this context, this review gives a summary of tools and databases that currently are available to mine, identify and characterize natural product biosynthesis pathways and their producers based on ‘omics data. A web portal called Secondary Metabolite Bioinformatics Portal (SMBP at http...... analytical and chemical methods gave access to this group of compounds, nowadays genomics-based methods offer complementary approaches to find, identify and characterize such molecules. This paradigm shift also resulted in a high demand for computational tools to assist researchers in their daily work......Natural products are among the most important sources of lead molecules for drug discovery. With the development of affordable whole-genome sequencing technologies and other ‘omics tools, the field of natural products research is currently undergoing a shift in paradigms. While, for decades, mainly...

  18. A Preliminary Study Application Clustering System in Acoustic Emission Monitoring

    Directory of Open Access Journals (Sweden)

    Saiful Bahari Nur Amira Afiza

    2017-01-01

    Full Text Available Acoustic Emission (AE is a non-destructive testing known as assessment on damage detection in structural engineering. It also can be used to discriminate the different types of damage occurring in a composite materials. The main problem associated with the data analysis is the discrimination between the different AE sources and analysis of the AE signal in order to identify the most critical damage mechanism. Clustering analysis is a technique in which the set of object are assigned to a group called cluster. The objective of the cluster analysis is to separate a set of data into several classes that reflect the internal structure of data. In this paper was used k-means algorithm for partitioned clustering method, numerous effort have been made to improve the performance of application k-means clustering algorithm. This paper presents a current review on application clustering system in Acoustic Emission.

  19. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    Science.gov (United States)

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  20. Application of transient analysis methodology to heat exchanger performance monitoring

    International Nuclear Information System (INIS)

    Rampall, I.; Soler, A.I.; Singh, K.P.; Scott, B.H.

    1994-01-01

    A transient testing technique is developed to evaluate the thermal performance of industrial scale heat exchangers. A Galerkin-based numerical method with a choice of spectral basis elements to account for spatial temperature variations in heat exchangers is developed to solve the transient heat exchanger model equations. Testing a heat exchanger in the transient state may be the only viable alternative where conventional steady state testing procedures are impossible or infeasible. For example, this methodology is particularly suited to the determination of fouling levels in component cooling water system heat exchangers in nuclear power plants. The heat load on these so-called component coolers under steady state conditions is too small to permit meaningful testing. An adequate heat load develops immediately after a reactor shutdown when the exchanger inlet temperatures are highly time-dependent. The application of the analysis methodology is illustrated herein with reference to an in-situ transient testing carried out at a nuclear power plant. The method, however, is applicable to any transient testing application

  1. Quantitative vs. subjective portal verification using digital portal images

    International Nuclear Information System (INIS)

    Bissett, Randy; Leszczynski, Konrad; Loose, Stephen; Boyko, Susan; Dunscombe, Peter

    1996-01-01

    Purpose: Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Methods and Materials: Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamber matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. Results: All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 deg. . For all

  2. Personal dose monitoring in hospitals: Global assessment, critical applications and future needs

    International Nuclear Information System (INIS)

    Covens, P.; Berus, D.; Buls, N.; Clerinx, P.; Vanhavere, F.

    2007-01-01

    It is known that medical applications using ionising radiation are wide spread and still increasing. Physicians, technicians, nurses and others constitute the largest group of workers occupationally exposed to man-made sources of radiation. Many hospital workers are consequently subjected to routine monitoring of professional radiation exposures. in the university hospital, UZ Brussel, 600 out of 4000 staff members are daily monitored for external radiation exposures. The most obvious applications of ionising radiation are diagnostic radiology, diagnostic or therapeutic use of radionuclides in nuclear medicine and external radiation therapy or brachytherapy in radiotherapy departments. Other important applications also include various procedures in interventional radiology (IR), in vitro biomedical research and radiopharmaceutical production around cyclotrons. Besides the fact that many of the staff members, involved in these applications, are not measurably exposed, detailed studies were carried out at workplaces where routine dose monitoring encounters difficulties and for some applications where relatively high occupational exposures can be found. most of the studies are concentrated around nuclear medicine applications and IR. They contain assessments of both effective dose and doses at different parts of the body. The results contribute to better characterisation of the different workplaces in a way that critical applications can be identified. Moreover, conclusions point out future needs for practical routine dose monitoring and optimisation of radiation protection. (authors)

  3. Dietary assessment and self-monitoring with nutrition applications for mobile devices.

    Science.gov (United States)

    Lieffers, Jessica R L; Hanning, Rhona M

    2012-01-01

    Nutrition applications for mobile devices (e.g., personal digital assistants, smartphones) are becoming increasingly accessible and can assist with the difficult task of intake recording for dietary assessment and self-monitoring. This review is a compilation and discussion of research on this tool for dietary intake documentation in healthy populations and those trying to lose weight. The purpose is to compare this tool with conventional methods (e.g., 24-hour recall interviews, paper-based food records). Research databases were searched from January 2000 to April 2011, with the following criteria: healthy or weight loss populations, use of a mobile device nutrition application, and inclusion of at least one of three measures, which were the ability to capture dietary intake in comparison with conventional methods, dietary self-monitoring adherence, and changes in anthropometrics and/or dietary intake. Eighteen studies are discussed. Two application categories were identified: those with which users select food and portion size from databases and those with which users photograph their food. Overall, positive feedback was reported with applications. Both application types had moderate to good correlations for assessing energy and nutrient intakes in comparison with conventional methods. For self-monitoring, applications versus conventional techniques (often paper records) frequently resulted in better self-monitoring adherence, and changes in dietary intake and/or anthropometrics. Nutrition applications for mobile devices have an exciting potential for use in dietetic practice.

  4. A heuristic approach to edge detection in on-line portal imaging

    International Nuclear Information System (INIS)

    McGee, Kiaran P.; Schultheiss, Timothy E.; Martin, Eric E.

    1995-01-01

    Purpose: Portal field edge detection is an essential component of several postprocessing techniques used in on-line portal imaging, including field shape verification, selective contrast enhancement, and treatment setup error detection. Currently edge detection of successive fractions in a multifraction portal image series involves the repetitive application of the same algorithm. As the number of changes in the field is small compared to the total number of fractions, standard edge detection algorithms essentially recalculate the same field shape numerous times. A heuristic approach to portal edge detection has been developed that takes advantage of the relatively few changes in the portal field shape throughout a fractionation series. Methods and Materials: The routine applies a standard edge detection routine to calculate an initial field edge and saves the edge information. Subsequent fractions are processed by applying an edge detection operator over a small region about each point of the previously defined contour, to determine any shifts in the field shape in the new image. Failure of this edge check indicates that a significant change in the field edge has occurred, and the original edge detection routine is applied to the image. Otherwise the modified edge contour is used to define the new edge. Results: Two hundred and eighty-one portal images collected from an electronic portal imaging device were processed by the edge detection routine. The algorithm accurately calculated each portal field edge, as well as reducing processing time in subsequent fractions of an individual portal field by a factor of up to 14. Conclusions: The heuristic edge detection routine is an accurate and fast method for calculating portal field edges and determining field edge setup errors

  5. Middleware and Web Services for the Collaborative Information Portal of NASA's Mars Exploration Rovers Mission

    Science.gov (United States)

    Sinderson, Elias; Magapu, Vish; Mak, Ronald

    2004-01-01

    We describe the design and deployment of the middleware for the Collaborative Information Portal (CIP), a mission critical J2EE application developed for NASA's 2003 Mars Exploration Rover mission. CIP enabled mission personnel to access data and images sent back from Mars, staff and event schedules, broadcast messages and clocks displaying various Earth and Mars time zones. We developed the CIP middleware in less than two years time usins cutting-edge technologies, including EJBs, servlets, JDBC, JNDI and JMS. The middleware was designed as a collection of independent, hot-deployable web services, providing secure access to back end file systems and databases. Throughout the middleware we enabled crosscutting capabilities such as runtime service configuration, security, logging and remote monitoring. This paper presents our approach to mitigating the challenges we faced, concluding with a review of the lessons we learned from this project and noting what we'd do differently and why.

  6. Treatment of portal hypertension caused by benign main portal vein stenosis with endovascular stent

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Guan Shouhai; Zhu Kangshun; Li Zhengran; Zhou Yubin; He Bingjun

    2004-01-01

    Objective: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Methods: Portal vein stents were implanted in 6 patients with benign main portal vein stenosis (inflammatory stenosis in 3 cases, postprocedure of liver transplantation in another 3 cases). The change of portal vein pressure, the patency of portal vein, relative clinical symptoms, complications, and survival were evaluated. Results: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in all 6 patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3 ± 4.7) cm H 2 O (1 cm H 2 O=0.098 kPa) to (18.0 ± 1.9) cm H 2 O (P<0.001). The portal blood flow was restored, and the symptoms caused by portal hypertension were eliminated. There was no severe procedure-related complication. Follow-up time was from 5 to 36 months. The portal vein remained patent during the follow-up. All patients survived except one patient who died of other complications of liver transplantation. Conclusion: Percutaneous portal vein stent placement for the treatment of the benign main portal vein stenosis is safe and effective. (authors)

  7. Strength monitoring of bridge constructions and features of its application. Part 2. Continuous monitoring of bridge construction status

    Directory of Open Access Journals (Sweden)

    Ovchinnikov Igor Georgievich

    2014-06-01

    Full Text Available The article describes a system of continuous monitoring of bridge constructions — a system of observation over the operating conditions and behavior of the bridge structure, which is aimed at ensuring the preservation of its functional application properties within the specified limits, realized on the continuous, long-term basis with the use of instrumentation and ensures on-line presentation of information on the status of structure. To illustrate, one may consider the existing systems of continuous monitoring for a number of bridge constructions in the United States, Japan, Europe, South Korea, Greece and Russia. The article suggests to examine the systems of continuous monitoring of «Commodore John Barry» truss bridge, «Akashi-Kaikyo» suspension bridge, «Siggenthal» reinforced-concrete arch bridge, «Nimhe» suspension bridge, «Jindo»cable-stayed bridge, «Yandzhon» suspension bridge, «Banghwa» bridge, «Seohae» bridge and «Rio-Antirrio» bridge. In addition one may consider monitoring of the longitudinal launching of the bridge superstructures over the Volga River near the village Pristannoye in Saratov region. Finally, it was drawn the conclusion that monitoring of bridge constructions from the standpoint of their consumers is aimed at solving such important problems as preservation of bridge structures, increase in service life of bridge structures through timely detection of faults and their elimination, as well as preservation of bridge structure carrying capacity by controlling their behavior during the operation and improving the efficiency of expenditure of monetary resources for repair activities by correct determination of time and type of the necessary repair.

  8. A new temperature threshold detector - Application to missile monitoring

    Science.gov (United States)

    Coston, C. J.; Higgins, E. V.

    Comprehensive thermal surveys within the case of solid propellant ballistic missile flight motors are highly desirable. For example, a problem involving motor failures due to insulator cracking at motor ignition, which took several years to solve, could have been identified immediately on the basis of a suitable thermal survey. Using conventional point measurements, such as those utilizing typical thermocouples, for such a survey on a full scale motor is not feasible because of the great number of sensors and measurements required. An alternate approach recognizes that temperatures below a threshold (which depends on the material being monitored) are acceptable, but higher temperatures exceed design margins. In this case hot spots can be located by a grid of wire-like sensors which are sensitive to temperature above the threshold anywhere along the sensor. A new type of temperature threshold detector is being developed for flight missile use. The considered device consists of KNO3 separating copper and Constantan metals. Above the KNO3 MP, galvanic action provides a voltage output of a few tenths of a volt.

  9. Applications of small surface plasmon resonance sensors for biochemical monitoring

    Science.gov (United States)

    Masson, Jean-Francois; Battaglia, Tina M.; Beaudoin, Stephen; Booksh, Karl S.

    2004-12-01

    The development of small surface plasmon resonance (SPR) sensors to detect biological markers for myocardial ischemia (MI), spinal muscular atrophy (SMA), and wound healing was achieved at low ng/mL and in less than 10 minutes. The markers of interest for MIs are myoglobin (MG) and cardiac Troponin I (cTnI). The limits of detection for these markers are respectively 600 pg/mL and 1.4 ng/mL in saline solution. To study SMA, the level of survival motor neuron protein (SMN) was investigated. A limit of detection of 990 pg/mL was achieved for the detection of SMN. The interactions of SMN with MG decreased the signal for both SMN and MG. Interleukin 6 and tumor necrosis factor alpha (TNFa) were investigated to monitor wound healing. The sensor's performance in more complex solutions, e.g.: serum, showed a large non-specific signal. Modifying the support on which the antibodies are attached improved the sensor's stability in serum by a factor of 5. To achieve this non-specific binding (NSB) reduction, different polysaccharides, biocompatible polymers and short chain thiols were investigated.

  10. Prognostics and Health Monitoring: Application to Electric Vehicles

    Science.gov (United States)

    Kulkarni, Chetan S.

    2017-01-01

    As more and more autonomous electric vehicles emerge in our daily operation progressively, a very critical challenge lies in accurate prediction of remaining useful life of the systemssubsystems, specifically the electrical powertrain. In case of electric aircrafts, computing remaining flying time is safety-critical, since an aircraft that runs out of power (battery charge) while in the air will eventually lose control leading to catastrophe. In order to tackle and solve the prediction problem, it is essential to have awareness of the current state and health of the system, especially since it is necessary to perform condition-based predictions. To be able to predict the future state of the system, it is also required to possess knowledge of the current and future operations of the vehicle.Our research approach is to develop a system level health monitoring safety indicator either to the pilotautopilot for the electric vehicles which runs estimation and prediction algorithms to estimate remaining useful life of the vehicle e.g. determine state-of-charge in batteries. Given models of the current and future system behavior, a general approach of model-based prognostics can be employed as a solution to the prediction problem and further for decision making.

  11. Atmosphere composition monitor for space station and advanced missions application

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Powell, F.T.

    1987-01-01

    Long-term human occupation of extraterrestrial locations may soon become a reality. The National Aeronautics and Space Administration (NASA) has recently completed the definition and preliminary design of the low earth orbit (LEO) space station. They are now currently moving into the detailed design and fabrication phase of this space station and are also beginning to analyze the requirements of several future missions that have been identified. These missions include, for example, Lunar and Mars sorties, outposts, bases, and settlements. A requirement of both the LEO space station and future missions are environmental control and life support systems (ECLSS), which provide a comfortable environment for humans to live and work. The ECLSS consists of several major systems, including atmosphere revitalization system (ARS), atmosphere pressure and composition control system, temperature and humidity control system, water reclamation system, and waste management system. Each of these major systems is broken down into subsystems, assemblies, units, and instruments. Many requirements and design drivers are different for the ECLSS of the LEO space station and the identified advanced missions (e.g., longer mission duration). This paper discusses one of the ARS assemblies, the atmosphere composition monitor assembly (ACMA), being developed for the LEO space station and addresses differences that will exist for the ACMA of future missions

  12. The application of external vibration monitoring to reactors with concrete pressure vessels

    International Nuclear Information System (INIS)

    Hammill, W.J.

    1979-01-01

    The application of external vibration monitoring techniques to advanced gas cooled reactors (AGR) which have concrete pressure vessels is considered. A monitoring system for a particular AGR coolant circuit structure is developed, whose primary objective is to detect impacting of two components, although the detection of forced vibration response is also considered. Experimental results from instrumented components in the reactor and data from rig tests on full size units have been used together with a mathematical model of some elements of the transmission path in order to establish its dynamic characteristics and relate internal component vibration to externally measured signals. The application of external vibration monitoring to the external detection of the forced vibration response of an internal reactor assembly and the remote monitoring of circulator sound output is discussed. (author)

  13. Editor's welcome, PORTAL, Vol. 1, No. 2, July 2004

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2005-03-01

    Full Text Available Since the highly successful inauguration of PORTAL in January 2004, we have received many kind expressions of support from international studies practitioners in a range of fields, and from such places as Canada, Italy, Mexico, Nigeria, New Zealand, Spain, Trinidad, the U.K., and the U.S.A. Particularly gratifying have been the endorsements of the journal and its publishing aims by people involved in their own electronic publishing enterprises. For their generous responses to PORTAL, the Editorial Committee would like to express its collective appreciation to the following people: Professor Jean-Marie Volet, of the University of Western Australia, and the guiding editor of the ground-breaking e-journal Mots Pluriels (www.arts.uwa.edu.au/MotsPluriels; and Francis Leo Collins, member of the Editorial Committee for the Graduate Journal of Asia Pacific Studies (GJAPS, based in Auckland, New Zealand. PORTAL's readers may be interested in the current call for papers from GJAPS (www.arts.auckland.ac.nz/gjaps, for a special issue on "Imagining the Asia-Pacific" (deadline October 31, 2004. This issue of PORTAL contains essays that cover wide terrain: the Chilean diasporic community in Australia; the world of German intellectuals; contemporary Mexican socio-political movements; rural-urban migration in China; and transnational advocacy networks and election monitoring in the Philippines, Chile, Nicaragua and Mexico. In the cultural section of this issue, we are delighted to present a short story from the noted German Studies scholar Anthony Stephens, and the first half of a beautiful, deeply poetic and haunting novel entitled Son, from the London-based writer and art-critic Jennifer Higgie. The novel’s second and final part will appear in PORTAL vol. 2, no. 1, in January 2005. On a different note, we would like to express our support for the inaugural Ubud Writers and Readers Festival, to be held in Ubud, Bali, from October 11 to 17, 2004. The Festival

  14. DEVELOPMENT OF EDUCATION AND INFORMATION PORTAL OF PHYSICS ACADEMIC COURSE: WEB DESIGN FEATURES

    Directory of Open Access Journals (Sweden)

    Іryna A. Slipukhina

    2018-04-01

    Full Text Available The purpose of this article is to present the main components and features of designing an educational and informational portal for students. Selection of personal trajectory is realized through the use of personal account, which includes electronic laboratory reports, information materials on studying progress, means of communication with a teacher, etc. The created portal allows the administrator to easily monitor and check laboratory reports, keep an e-journal with grades. To develop the website design, functional modules and components, the Adobe Photoshop ™ environment was used, as well as the HTML and CSS layout of the web portal. The modern Bootstrap technology was applied to adapt the web page interface. The didactic opportunities of using this portal as a part of personalization process in teaching physics were considered.

  15. The questions of working out radiology patterns of portal hypertension

    International Nuclear Information System (INIS)

    Vyikman, Ya.E.

    2008-01-01

    A foundation for radiological patterns of each type of portal hypertension (PH) at various stages of its development. Portal blood pressure, diameter of splenic and portal veins, volume blood flow velocity in the portal and splenic veins, incidence of hypersplenism, enlargement of the caudate lobe of the liver and gallbladder fossa are the most informative in differentiation of various forms of portal hypertension

  16. Basic characteristics of hollow-filament polyimide membrane in gas separation and application to tritium monitors

    International Nuclear Information System (INIS)

    Sasaki, Sh.; Suzuki, T.; Kondo, K.; Tega, E.; Shimada, A.; Akahori, S.; Okuno, K.

    2003-01-01

    The separation efficiency of hollow-filament polyimide membranes for 3 H and 41 Ar is preliminarily examined for a potential application to continuous gas monitoring systems for analysis of stack emission from accelerator facilities. The basic gas separation characteristics of the membranes are experimentally investigated, and a preliminary gas monitor design is proposed. The membranes are capable of selectively enriching hydrogen by more than 25 times, with negligible variation with respect to the species of isotope. (author)

  17. Application of single-chip microcomputer to portable radon and radon daughters monitor

    International Nuclear Information System (INIS)

    Meng Yecheng; Huang Zhanyun; She Chengye

    1992-01-01

    Application of single-chip microcomputer to portable radon and radon daughters monitor is introduced in this paper. With the single-chip microcomputer automation comes into effect in the process from sampling to measuring of radon and radon daughters. The concentrations of radon and radon daughters can be easily shown when the conversion coefficients are pre-settled before the measurement. Moreover, the principle and design are briefly discussed according to the characteristics of the monitor

  18. Application impact of internal monitoring criteria in radiological protection programs of nuclear medicine services

    International Nuclear Information System (INIS)

    Dantas, Bernardo M.; Dantas, Ana Leticia A.; Juliao, Ligia Q.C.; Lourenco, Maria Cristina; Melo, Dunstana R.

    2005-01-01

    This work presents the simulation of the internal monitoring criteria application for the most used radionuclides by the area of nuclear medicine, taking into consideration the usual conditions of usual source handling and the activity bands authorized by the CNEN. It is concluded that the handling of Iodine 131 for therapeutical purposes is the practice which presents the most risk of internal exposure for the works, requiring the adoption of a program for internal monitoring by the nuclear medicine services

  19. Safeguard Application Options for the Laser-Based Item Monitoring System (LBIMS)

    International Nuclear Information System (INIS)

    Laughter, Mark D

    2008-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) are developing a Laser-Based Item Monitoring System (LBIMS) for advanced safeguards at nuclear facilities. LBIMS uses a low-power laser transceiver to monitor the presence and position of items with retroreflective tags. The primary advantages of LBIMS are its scalability to continuously monitor a wide range of items, its ability to operate unattended, its low cost of implementation, and its inherent information security due to its line-of-sight and non-broadcasting operation. The primary proposed safeguard application of LBIMS is described in its name: item monitoring. LBIMS could be implemented in a storage area to continuously monitor containers of nuclear material and the area in which they are stored. The system could be configured to provide off-site notification if any of the containers are moved or removed or if the area is accessed. Individual tags would be used to monitor storage containers, and additional tags could be used to record information regarding secondary storage units and room access. The capability to register small changes in tag position opens up the possibility of several other uses. These include continuously monitoring piping arrangements for design information verification or recording equipment positions for other safeguards systems, such as tracking the opening and closing of autoclaves as part of a cylinder tracking system or opening and closing valves on a sample or product take-off line. Combined with attribute tags, which transmit information from any kind of sensor by modulating the laser signal, LBIMS provides the capability to wirelessly and securely collect safeguards data, even in areas where radio-frequency or other wireless communication methods are not practicable. Four application types are described in this report: static item monitoring, in-process item monitoring with trigger tags, multi-layered integration with trigger tags, and line-of-sight data transfer with

  20. Ballast water compliance monitoring: A new application for ATP

    Science.gov (United States)

    Lo Curto, A.; Stehouwer, P.; Gianoli, C.; Schneider, G.; Raymond, M.; Bonamin, V.

    2018-03-01

    The coming into force of the USCG ballast water regulations and the IMO ballast water management convention resulted in the development of several technologies approved for the treatment of ballast water. To ensure compliance of these technologies, the development of rapid and robust analysis methods was necessary. In collaboration with the SGS Group (Switzerland) and LuminUltra (Canada), Aqua-tools (France) has developed an innovative Ballast Water Treatment Monitoring (BWTM) kit for rapid onboard testing. The affordable kit provides results in less than 1 h, is easy to use and durable ensuring that the ballast water treatment system on the ship is fully compliant with the discharge standards upon arrival in port. The core of this method is a combination of high-quality reagents (lysis solution and ATP 2G Luminase™ enzyme) not inhibited by salinity and a patented fast homogenizing method for ATP extraction developed for a higher ATP recovery from zooplankton and phytoplankton. Compared to traditional analysis methods, the BWTM Kit provides fast and accurate results for all three fractions of microorganisms (≥ 50 μm, ≥ 10 ÷ < 50 μm and bacteria). Preliminary tests carried out in cooperation with SGS showed that the proposed method was able to detect onboard the efficiency of the treatment systems used. Compliance limits were established for all size fractions and a correlation between the standard methods (microscopy, plate count, MPN) and ATP was evaluated. The BWTM kit can provide a fast indication of compliance or gross exceedance. The rare borderline cases, when encountered, of course require additional confirmation.

  1. Optoelectronic sensor device for monitoring ethanol concentration in winemaking applications

    Science.gov (United States)

    Jiménez-Márquez, F.; Vázquez, J.; Úbeda, J.; Rodríguez-Rey, J.; Sánchez-Rojas, J. L.

    2015-05-01

    The supervision of key variables such as sugar, alcohol, released CO2 and microbiological evolution in fermenting grape must is of great importance in the winemaking industry. However, the fermentation kinetics is assessed by monitoring the evolution of the density as it varies during a fermentation, since density is an indicator of the total amount of sugars, ethanol and glycerol. Even so, supervising the fermentation process is an awkward and non-comprehensive task, especially in wine cellars where production rates are massive, and enologists usually measure the density of the extracted samples from each fermentation tank manually twice a day. This work aims at the design of a fast, low-cost, portable and reliable optoelectronic sensor for measuring ethanol concentration in fermenting grape must samples. Different sets of model solutions, which contain ethanol, fructose, glucose, glycerol dissolved in water and emulate the grape must composition at different stages of the fermentation, were prepared both for calibration and validation. The absorption characteristics of these model solutions were analyzed by a commercial spectrophotometer in the NIR region, in order to identify key wavelengths from which valuable information regarding the sample composition can be extracted. Finally, a customized optoelectronic prototype based on absorbance measurements at two wavelengths belonging to the NIR region was designed, fabricated and successfully tested. The system, whose optoelectronics is reduced after a thorough analysis to only two LED lamps and their corresponding paired photodiodes operating at 1.2 and 1.3 μm respectively, calculates the ethanol content by a multiple linear regression.

  2. Application of Structure Monitoring Systems to the Assessment of the Behaviour of Bridges in Mining Areas

    Science.gov (United States)

    Parkasiewicz, Beata; Kadela, Marta; Bętkowski, Piotr; Sieńko, Rafał; Bednarski, Łukasz

    2017-10-01

    Structure monitoring systems are increasingly used to assess the technical condition and improve the safety of structures. Monitoring the structural behaviour becomes necessary in the case of structures located in areas with complicated ground conditions. Due to the risk of failures and the resulting economic and non-material costs, monitoring should be in particular applied to linear structures, including railways, tramlines, motorways and expressways, as well as related facilities (e.g. bridges). Monitoring shall consist in regular observations, measurements and documenting all significant data during construction, after its completion and during usage, and in analysing and evaluating the results. This paper presents the application of structure monitoring systems to the assessment of the behaviour of bridges exposed to the impact of mining operations.

  3. [Predictive value of ultrasonography in portal hypertension].

    Science.gov (United States)

    Moreno, E; Torres, P; Trejo, C; Barra Ostoni, V; Ortega, C; Römer, H

    1991-01-01

    Portal hypertension is a common pathology in childhood and one of its most common causes is cavernomatosis of the portal vein. This obstruction causes hemodynamic changes which lead to splenomegaly and collateral circulation. Esophageal varices are one of the most important sequelae, which endanger the patient's life because of a bleeding tendency. Ecosonography helps to detect the thickening of the lesser omentum vis a vis the aortic diameter, caused by the collateral circulation. We studied 15 children presenting with portal hypertension resulting from portal vein cavernomatosis; we performed an upper GI endoscopy and abdominal ecosonography. The endoscopy revealed grade II esophageal varices in 20% of cases, the remaining 80% had grade III and grade IV. Ecosonography revealed an increased lesser omentum/aorta ratio in children with portal hypertension, compared to controls (p portal hypertension.

  4. Study in rabbits of portal circulation by a radioisotopic method

    International Nuclear Information System (INIS)

    Maliska, C.

    1980-01-01

    The development of a precocius - and noninvasive method for the detection of portal circulation alterations by means of time interval measurements between the rectal administration of radiotracers and their detection in liver and head is aimed at. The pertecnetate ( 99 sup(m)Tc)- and iodate ( 131 I) absorption by the terminal large intestine was tested in 22 rabbits. The time iinterval between rectal administration of the radiotracer and its appearance in liver and head was determined in 12 rabbits, by external detection with a scintillation camera. The same parameters were studied in 9 animals submitted to the ligature of the portal vein. Iodate and pertecnetate are absorbed by the terminal large intestine, the pertecnetate absorption being significantly smaller than that of iodate. The pertecnetate distribution volume is smaller than that of iodate; the rectum - liver - and rectum - head time intervals is increased in animals with the ligature of portal vein. Application of the method to larger animals will permit the necessary improvements for its utilization as a precocius - noninvasive - and inocuous test in the evaluation of alteration of the human portal circulation. (Author) [pt

  5. Application of Nucleic Acid-Based Tools for Monitoring Monitored Natural Attenuation (MNA), Biostimulation and Bioaugmentation at Chlorinated Solvent Sites

    Science.gov (United States)

    2011-02-01

    KIRKWOOD FORMATION) (MANASQUAN FORMATION) (VINCENTOWN FORMATION) MONITORING WELL MONITORING WELL MONITORING WELL CHAIN LINK FENCE TREELINE INTERMITTENT...VINCENTOWN FORMATION) MONITORING WELL MONITORING WELL MONITORING WELL CHAIN LINK FENCE TREELINE INTERMITTENT STREAM INTERVAL (ug/L) LEGEND: MAG-201 LOOP 1

  6. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  7. submitter The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    CERN Document Server

    Antonuccio, V; Becciani, U; Bonanno, D L; Bonanno, G; Bongiovanni, D; Fallica, P G; Garozzo, S; Grillo, A; La Rocca, P; Leonora, E; Longhitano, F; Lo Presti, D; Marano, D; Parasole, O; Pugliatti, C; Randazzo, N; Riggi, F; Riggi, S; Romeo, G; Romeo, M; Russo, G V; Santagati, G; Timpanaro, M C; Valvo, G

    2017-01-01

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype $(6×3×7 m^3)$ for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as o...

  8. The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    Energy Technology Data Exchange (ETDEWEB)

    Antonuccio, V. [INAF - Osservatorio Astrofisico di Catania (Italy); Bandieramonte, M. [CERN, Geneva (Switzerland); Becciani, U. [INAF - Osservatorio Astrofisico di Catania (Italy); Bonanno, D.L., E-mail: danilo.bonanno@ct.infn.it [INFN Sezione di Catania, Catania (Italy); Bonanno, G. [INAF - Osservatorio Astrofisico di Catania (Italy); Bongiovanni, D. [INFN Sezione di Catania, Catania (Italy); Fallica, P.G. [STMicroelectronics, Catania (Italy); Garozzo, S.; Grillo, A. [INAF - Osservatorio Astrofisico di Catania (Italy); La Rocca, P. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Leonora, E.; Longhitano, F. [INFN Sezione di Catania, Catania (Italy); Lo Presti, D. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Marano, D. [INAF - Osservatorio Astrofisico di Catania (Italy); Parasole, O. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Pugliatti, C. [Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Randazzo, N. [INFN Sezione di Catania, Catania (Italy); Riggi, F. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Riggi, S. [INAF - Osservatorio Astrofisico di Catania (Italy); INFN Sezione di Catania, Catania (Italy); Romeo, G. [INAF - Osservatorio Astrofisico di Catania (Italy); and others

    2017-02-11

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype (6×3×7 m{sup 3}) for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as on the preliminary results obtained with the first detection planes.

  9. The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    Science.gov (United States)

    Antonuccio, V.; Bandieramonte, M.; Becciani, U.; Bonanno, D. L.; Bonanno, G.; Bongiovanni, D.; Fallica, P. G.; Garozzo, S.; Grillo, A.; La Rocca, P.; Leonora, E.; Longhitano, F.; Lo Presti, D.; Marano, D.; Parasole, O.; Pugliatti, C.; Randazzo, N.; Riggi, F.; Riggi, S.; Romeo, G.; Romeo, M.; Russo, G. V.; Santagati, G.; Timpanaro, M. C.; Valvo, G.

    2017-02-01

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype (6×3×7 m3) for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as on the preliminary results obtained with the first detection planes.

  10. Application of GIS Rapid Mapping Technology in Disaster Monitoring

    Science.gov (United States)

    Wang, Z.; Tu, J.; Liu, G.; Zhao, Q.

    2018-04-01

    With the rapid development of GIS and RS technology, especially in recent years, GIS technology and its software functions have been increasingly mature and enhanced. And with the rapid development of mathematical statistical tools for spatial modeling and simulation, has promoted the widespread application and popularization of quantization in the field of geology. Based on the investigation of field disaster and the construction of spatial database, this paper uses remote sensing image, DEM and GIS technology to obtain the data information of disaster vulnerability analysis, and makes use of the information model to carry out disaster risk assessment mapping.Using ArcGIS software and its spatial data modeling method, the basic data information of the disaster risk mapping process was acquired and processed, and the spatial data simulation tool was used to map the disaster rapidly.

  11. Application of a microprocessor system to stream monitoring

    International Nuclear Information System (INIS)

    Oakes, T.W.; Shank, K.E.

    1978-01-01

    Low-level liquid wastes originating from the Oak Ridge National Laboratory (ORNL) are discharged, after treatment, into White Oak Creek, which is a small tributary of the Clinch River located in East Tennessee. Samples of White Oak Creek discharges are collected at White Oak Dam by a continuous digital proportional water sampler and analyzed weekly for radioactivity. The sampler contains a control system with a microprocessor that has been programmed to solve nonlinear weir equations. This system was designed and installed at ORNL by the Instrumentation and Controls Division and was tested by the Environmental Surveillance and Evaluation Section of the Industrial Safety and Applied Health Physics Division. The control system was designed to measure water flow rates from 0 to 334 ft 3 /sec to within 0.1%. Results of our test program and possible applications to other liquid sampling needs are discussed

  12. Development and Application of a Structural Health Monitoring System Based on Wireless Smart Aggregates.

    Science.gov (United States)

    Yan, Shi; Ma, Haoyan; Li, Peng; Song, Gangbing; Wu, Jianxin

    2017-07-17

    Structural health monitoring (SHM) systems can improve the safety and reliability of structures, reduce maintenance costs, and extend service life. Research on concrete SHMs using piezoelectric-based smart aggregates have reached great achievements. However, the newly developed techniques have not been widely applied in practical engineering, largely due to the wiring problems associated with large-scale structural health monitoring. The cumbersome wiring requires much material and labor work, and more importantly, the associated maintenance work is also very heavy. Targeting a practical large scale concrete crack detection (CCD) application, a smart aggregates-based wireless sensor network system is proposed for the CCD application. The developed CCD system uses Zigbee 802.15.4 protocols, and is able to perform dynamic stress monitoring, structural impact capturing, and internal crack detection. The system has been experimentally validated, and the experimental results demonstrated the effectiveness of the proposed system. This work provides important support for practical CCD applications using wireless smart aggregates.

  13. Space weather monitoring with neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian [Christian-Albrechts-Universitaet zu Kiel (Germany)

    2013-07-01

    Space Weather affects many areas of the modern society, advance knowledge about space weather events is important to protect personnel and infrastructure. Cosmic Rays (CR) measurements by ground-based Neutron Monitors are influenced by Coronal Mass Ejections (CME), the intensity of the ever present Cosmic Rays is reduced in a Forbush decrease (Fd). In the case of very energetic CMEs, the measured intensity can be significantly increased in a Ground Level Enhancement (GLE). By detecting the anisotropy of the CR environment, a CME can be detected hours before it arrives at Earth. During a GLE the high-energy particles from the Sun can be detected before the more abundant lower energy particles arrive at Earth, thus allowing to take protective measures. Since the beginning of the Neutron Monitor Database (NMDB) project, which has been started in 2008 with funding from the European Commission, real-time data from Neutron Monitors around the world has been made available through one web-portal. We have more than doubled the number of stations providing data since the start of the project to now over 30 stations. The effectiveness of the ALERT applications which are based on NMDB data has been shown by the recent GLE71. We present different applications through which the measurements and different data products are accessible.

  14. Noncirrhotic portal fibrosis after Wilms' tumor therapy

    International Nuclear Information System (INIS)

    Barnard, J.A.; Marshall, G.S.; Neblett, W.W.; Gray, G.; Ghishan, F.K.

    1986-01-01

    A 9-yr-old girl developed massive hemorrhage from esophageal varices 2 yr after combined modality therapy for Wilms' tumor. Evaluation showed a patent extrahepatic portal venous system and an elevated splenic pulp pressure. In contrast to previous reports of hepatopathy after irradiation injury, histologic sections of the liver did not demonstrate occlusion of the central veins, but rather a diffuse obliteration of intrahepatic portal venous radicles. This pattern of noncirrhotic portal fibrosis has not been described following antitumor therapy

  15. A View on Electronic Learning Portals

    OpenAIRE

    Zavaraqi, Rasoul

    2009-01-01

    Portals are less than a decade old. They have come to cover are areas of electronic services, including electronic learning. With their efficient communication and information capabilities, these portals are capable of realizing novel learning concepts such as structuralism, active and cooperative learning. The present paper endeavors to discuss the latest understanding, theories and concepts regarding E-learning portals and to review the issues and steps that should be considered in designin...

  16. Preduodenal portal vein: its surgical significance.

    Science.gov (United States)

    Makey, D A; Bowen, J C

    1978-11-01

    Preduodenal portal vein is a rare anatomical variant which may be one of many anomalies in the neonate with duodenal "atresia." Preduodenal portal vein also may be an occasional finding in an adult undergoing biliary, gastric, or pancreatic surgery. Awareness and recognition of the anomaly are essential for the avoidance of injury during such operations. We report here a symptomless patient whose preduodenal portal vein was discovered at cholecystectomy.

  17. Web-based Service Portal in Healthcare

    Science.gov (United States)

    Silhavy, Petr; Silhavy, Radek; Prokopova, Zdenka

    Information delivery is one the most important task in healthcare. The growing sector of electronic healthcare has an important impact on the information delivery. There are two basic approaches towards information delivering. The first is web portal and second is touch-screen terminal. The aim of this paper is to investigate the web-based service portal. The most important advantage of web-based portal in the field of healthcare is an independent access for patients. This paper deals with the conditions and frameworks for healthcare portals

  18. Application of maximum radiation exposure values and monitoring of radiation exposure

    International Nuclear Information System (INIS)

    1993-01-01

    According to the Section 32 of the Radiation Act (592/91) the Finnish Centre for Radiation and Nuclear Safety gives instructions concerning the monitoring of the radiation exposure and the application of the dose limits in Finland. The principles to be applied to calculating the equivalent and the effective doses are presented in the guide. Also the detailed instructions on the application of the maximum exposure values for the radiation work and for the natural radiation as well as the instructions on the monitoring of the exposures are given. Quantities and units for assessing radiation exposure are presented in the appendix of the guide

  19. Applications of Wireless Sensor Networks in Marine Environment Monitoring: A Survey

    Science.gov (United States)

    Xu, Guobao; Shen, Weiming; Wang, Xianbin

    2014-01-01

    With the rapid development of society and the economy, an increasing number of human activities have gradually destroyed the marine environment. Marine environment monitoring is a vital problem and has increasingly attracted a great deal of research and development attention. During the past decade, various marine environment monitoring systems have been developed. The traditional marine environment monitoring system using an oceanographic research vessel is expensive and time-consuming and has a low resolution both in time and space. Wireless Sensor Networks (WSNs) have recently been considered as potentially promising alternatives for monitoring marine environments since they have a number of advantages such as unmanned operation, easy deployment, real-time monitoring, and relatively low cost. This paper provides a comprehensive review of the state-of-the-art technologies in the field of marine environment monitoring using wireless sensor networks. It first describes application areas, a common architecture of WSN-based oceanographic monitoring systems, a general architecture of an oceanographic sensor node, sensing parameters and sensors, and wireless communication technologies. Then, it presents a detailed review of some related projects, systems, techniques, approaches and algorithms. It also discusses challenges and opportunities in the research, development, and deployment of wireless sensor networks for marine environment monitoring. PMID:25215942

  20. Smartphone ownership and interest in mobile applications to monitor symptoms of mental health conditions.

    Science.gov (United States)

    Torous, John; Friedman, Rohn; Keshavan, Matcheri

    2014-01-21

    Patient retrospective recollection is a mainstay of assessing symptoms in mental health and psychiatry. However, evidence suggests that these retrospective recollections may not be as accurate as data collection though the experience sampling method (ESM), which captures patient data in "real time" and "real life." However, the difficulties in practical implementation of ESM data collection have limited its impact in psychiatry and mental health. Smartphones with the capability to run mobile applications may offer a novel method of collecting ESM data that may represent a practical and feasible tool for mental health and psychiatry. This paper aims to provide data on psychiatric patients' prevalence of smartphone ownership, patterns of use, and interest in utilizing mobile applications to monitor their mental health conditions. One hundred psychiatric outpatients at a large urban teaching hospital completed a paper-and-pencil survey regarding smartphone ownership, use, and interest in utilizing mobile applications to monitor their mental health condition. Ninety-seven percent of patients reported owning a phone and 72% reported that their phone was a smartphone. Patients in all age groups indicated greater than 50% interest in using a mobile application on a daily basis to monitor their mental health condition. Smartphone and mobile applications represent a practical opportunity to explore new modalities of monitoring, treatment, and research of psychiatric and mental health conditions.

  1. The analysis of educational portals for the area of ICT profession.

    OpenAIRE

    Vrbka, Jan

    2011-01-01

    This diploma thesis deals with electronic educational portals and their applicability in the area of ICT. The aim is to determine key knowledge and skills of ICT professionals and assign those to courses from educational portals. The work is divided into theoretical and practical part. The theoretical part consists of definitions of issues elaborated in this work. The particular attention is paid to education and e-learning. Practical part seeks to match key professional knowledge and skills ...

  2. Characterization of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry

    International Nuclear Information System (INIS)

    Boer, J.C.J. de; Visser, A.G.

    2000-01-01

    The application of a newly developed fluoroscopic (CCD-camera based) electronic portal imaging device (EPID) in portal dosimetry is investigated. A description of the EPID response to dose is presented in terms of stability, linearity and optical cross-talk inside the mechanical structure. The EPID has a relatively large distance (41 cm on-axis) between the fluorescent screen and the mirror (high-elbow), which results in cross-talk with properties quite different from that of the low-elbow fluoroscopic EPIDs that have been studied in the literature. In contrast with low-elbow systems, the maximum cross-talk is observed for points of the fluorescent screen that have the largest distance to the mirror, which is explained from the geometry of the system. An algorithm to convert the images of the EPID into portal dose images (PDIs) is presented. The correction applied for cross-talk is a position-dependent additive operation on the EPID image pixel values, with a magnitude that depends on a calculated effective field width. Deconvolution with a point spread function, as applied for low-elbow systems, is not required. For a 25 MV beam, EPID PDIs and ionization chamber measurements in the EPID detector plane were obtained behind an anthropomorphic phantom and a homogeneous absorber for various field shapes. The difference in absolute dose between the EPID and ionization chamber measurements, averaged over the four test fields presented in this paper, was 0.1±0.5% (1 SD) over the entire irradiation field, with no deviation larger than 2%. (author)

  3. Trial on MR portal blood flow measurement with phase contrast technique

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Togami, Izumi

    1991-01-01

    Portal blood flow measurement is considered to be important for the analysis of hemodynamics in various liver diseases. The Doppler ultrasound method has been used extensively during the past several years for measuring portal blood flow, as a non-invasive method. However, the Doppler ultrasound technique do not allow the portal blood flow to be measured in cases of obesity, with much intestinal gas, and so on. In this study, we attempted to measure the blood flow in the main trunk of portal vein as an application of MR phase contrast technique to the abdominal region. In the flow phantom study, the flow volumes and the velocities measured by phase contrast technique showed a close correlation with those measured by electromagnetic flowmeter. In the clinical study with 10 healthy volunteers, various values of portal blood flow were obtained. Mean portal blood flow could be measured within the measuring time (about 8 minutes) under natural breathing conditions. Phase contrast technique is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  4. Accessibility in e-government portals of the Judiciary

    Directory of Open Access Journals (Sweden)

    Mariana Pessini Mezzaroba

    2016-05-01

    Full Text Available This article deals with an analysis of the application of Macedo accessibility guidelines (2010 for the publication of texts on the Web. In this paper, e-government portals were observed, particularly the judiciary, using the Supreme Court site Federal (STF, to verify whether the available material allows people with some kind of visual disability to access it and become aware of its contents. We also used the model of accessibility in Electronic Government eMag, established by the Federal Government, through Decree n. 03 of 07 May 2007.It were also developed the graphical representation of synthesis (RGS addressed the issue. The analysis was performed from the application of e-government accessibility evaluator ASES (Appraiser and accessibility Simulator Sites, combining their results with the textual guidelines already mentioned. After analyzing the results, it shows a table with errors and recommendations to the portal.

  5. Periodic quality control of a linear accelerator using electronic portal imaging; Controles de calidad periodicos de un acelerador lineal utilizando el sistema electronico de imagenes portales

    Energy Technology Data Exchange (ETDEWEB)

    Planes Meseguer, D.; Dorado Rodriguez, M. P.; Esposito, R. D.

    2011-07-01

    In this paper we present our solution for the realization of the monthly periodic quality control (CP) geometry - mechanical and multi leaf collimator (MLC), using the electronic system for portal imaging (EPI). We have developed specific programs created with free software. The monitoring results are automatically stored on our web server, along with other information generated in our service.

  6. Patient portals - An online tool for your health

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000880.htm Patient portals - an online tool for your health To ... is private and secure. What is in a Patient Portal? With a patient portal, you can: Make ...

  7. Comparative Investigation of Ce3+ Doped Scintillators in a Wide Range of Photon Energies Covering X-ray CT, Nuclear Medicine and Megavoltage Radiation Therapy Portal Imaging Applications

    Science.gov (United States)

    Valais, Ioannis G.; Michail, Christos M.; David, Stratos L.; Liaparinos, Panagiotis F.; Fountos, George P.; Paschalis, Theodoros V.; Kandarakis, Ioannis S.; Panayiotakis, George S.

    2010-02-01

    The aim of the present work is to study the performance of scintillators currently used in PET and animal PET systems, under conditions met in radiation therapy and PET/CT imaging. The results of this study will be useful in applications where both CT and PET photons as well as megavoltage cone beam CT (MV CBCT) photons could be detected using a common detector unit. To this aim crystal samples of GSO, LSO, LYSO, LuYAP and YAP scintillators, doped with cerium (Ce+3) were examined under a wide energy range of photon energies. Evaluation was performed by determining the absolute luminescence efficiency (emitted light flux over incident X-ray exposure) in the energy range employed in X-ray CT, in Nuclear Medicine (70 keV up to 662 keV) and in radiotherapy 6 MV (approx. 2.0 MeV mean energy)-18 MV (approx. 4.5 MeV mean energy). Measurements were performed using an experimental set-up based on a photomultiplier coupled to a light integration sphere. The emission spectrum under X-ray excitation was measured, using an optical grating monochromator, to determine the spectral compatibility to optical photon detectors incorporated in medical imaging systems. Maximum absolute luminescence efficiency values were observed at 70 keV for YAP:Ce and LuYAP:Ce and at 140 keV for LSO:Ce, LYSO:Ce and GSO:Ce. Highest absolute efficiency between the scintillators examined was observed for LSO:Ce, followed by LYSO:Ce. The detector optical gain (DOG) exhibited a significant variation with the increase of energy between 70 keV to 2.0 MeV. All scintillators exhibited low compatibility when combined with GaAsP (G5645) photodetector.

  8. Global Application of the Assessment of Communication Skills of Paediatric Endocrinology Fellows in the Management of Differences in Sex Development Using the ESPE E-Learning.Org Portal.

    Science.gov (United States)

    Kranenburg, Laura J C; Reerds, Sam T H; Cools, Martine; Alderson, Julie; Muscarella, Miriam; Magrite, Ellie; Kuiper, Martijn; Abdelgaffar, Shereen; Balsamo, Antonio; Brauner, Raja; Chanoine, Jean Pierre; Deeb, Asma; Fechner, Patricia; German, Alina; Holterhus, Paul Martin; Juul, Anders; Mendonca, Berenice B; Neville, Kristen; Nordenstrom, Anna; Oostdijk, Wilma; Rey, Rodolfo A; Rutter, Meilan M; Shah, Nalini; Luo, Xiaoping; Grijpink, Kalinka; Drop, Stenvert L S

    2017-01-01

    Information sharing in chronic conditions such as disorders of/differences in sex development (DSD) is essential for a comprehensive understanding by parents and patients. We report on a qualitative analysis of communication skills of fellows undergoing training in paediatric endocrinology. Guidelines are created for the assessment of communication between health professionals and individuals with DSD and their parents. Paediatric endocrinology fellows worldwide were invited to study two interactive online cases (www.espe-elearning.org) and to describe a best practice communication with (i) the parents of a newborn with congenital adrenal hyperplasia and (ii) a young woman with 46,XY gonadal dysgenesis. The replies were analysed regarding completeness, quality, and evidence of empathy. Guidelines for structured assessment of responses were developed by 22 senior paediatric endocrinologists worldwide who assessed 10 selected replies. Consensus of assessors was established and the evaluation guidelines were created. The replies of the fellows showed considerable variation in completeness, quality of wording, and evidence of empathy. Many relevant aspects of competent clinical communication were not mentioned; 15% (case 1) and 17% (case 2) of the replies were considered poor/insufficient. There was also marked variation between 17 senior experts in the application of the guidelines to assess communication skills. The guidelines were then adjusted to a 3-level assessment with empathy as a separate key item to better reflect the qualitative differences in the replies and for simplicity of use by evaluators. E-learning can play an important role in assessing communication skills. A practical tool is provided to assess how information is shared with patients with DSD and their families and should be refined by all stakeholders, notably interdisciplinary health professionals and patient representatives. © 2017 S. Karger AG, Basel.

  9. Portal Web 2.0

    OpenAIRE

    Barba Hidalgo, José Manuel

    2008-01-01

    El tema que es tracta en aquest projecte gira al voltant del concepte Web 2.0. Després d’una introducció on es comenten les principals característiques que defineixen el conjunt d’aplicacions agrupades al voltant d’aquesta filosofia, s’analitzen diferents entorns de desenvolupament d’aplicacions Web, amb l’objectiu de crear un portal que segueixi els principis Web 2.0. El resultat de l’estudi presenta a Ruby on Rails com un ferm candidat, això fa que es procedeixi a estudiar aq...

  10. Portal web para comunicaciones seguras

    OpenAIRE

    Jurado Villalobos, Rodrigo

    2015-01-01

    Proyecto teórico-práctico de investigación, enfocado a obtener un mayor conocimiento del funcionamiento de los protocolos y funciones de seguridad criptógrafica así como explorar las limitaciones y buscar nuevas vías de implementar la seguridad de las comunicaciones a través del desarrollo de una aplicación que dé uso en un entorno “real” de estos protocolos de seguridad. Dicha aplicación consistirá en un portal web de mensajería entre usuarios que empleará sistemas criptográficos tanto en el...

  11. The investigation of nano-monitoring technology and the probability analysis of application of nuclear technology

    International Nuclear Information System (INIS)

    Kang Kejun; Wang Xuewu; Gao Wenhuan

    1999-01-01

    After several-decade of development, nano science/nano technology has become a scientific and technical frontier that with major trends foreseen in several disciplines. By connecting with the development of nano science/nano technology and considering the human body environment that the nano system is applicable in, the author analyzes the probability of the present nuclear detection technologies integrating and application with the monitoring of nano system, and draws an analysis of optimality choice

  12. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  13. Portal in the power sector - it is vision or reality?

    International Nuclear Information System (INIS)

    Hornak, L.

    2004-01-01

    The goal of the presentation is to introduce the portal solutions, to describe the types, characteristic features and abilities of the portal and to define required attributes of the portal in the power segment. The author will try to answer the questions whether such portal exists at the present time, what is needed in order to implement the portal and how to do the portal maintenance and management

  14. Mobile Application Monitoring Pengisian Uang Anjungan Tunai Mandiri PT Bank Mandiri Cabang Palembang

    Directory of Open Access Journals (Sweden)

    Usman Ependi

    2017-05-01

    Full Text Available Bank Mandiri Cabang Palembang merupakan bank yang mengedepankan kepuasan pelanggan. Salah satu pelayanan yang ada berupa pelayanan anjungan tunai mandiri (ATM yang menjadi ujung tombak dalam pendistribusian uang tunai kepada nasabah. Namun kendala yang saat ini muncul adanya proses yang kurang efisien dalam bidang penjadwalan dan monitoring pengisian uang pada ATM yang dimiliki. Kurang efisiennya proses tersebut meliputi proses pembuatan jadwal pengisian dan petugas pengisian yang masi menggunakan cara konvensional seperti perekapan melaui Microsoft exel dan dalam bentuk jadwal cetak. Sesuai kondisi tersebut maka dalam penelitian ini dibuat mobile application sebagai alat bantu dalam penjadwalan dan monitoring pengisian uang ATM. Mobile application yang dihasilkan telah dikembangkan secara sistematis dan terstruktur menggunakan metode pegnembangan mobile-D. selain  itu juga mobile applicatioan tersebut telah dilakukan pengujian sebagai langkah akhir pegnembangan dan dinyatakan layak (dapat diterima sehingga dapat dijadikan oleh Bank Mandiri Cabang Palembang sebagai alat bantu dalam proses penjadwalan dan monitoring pengisian uang ATM

  15. CMX - A Generic Solution to Expose Monitoring Metrics in C and C++ Applications

    CERN Document Server

    Ehm, F; Gorgogianni, G M; Jensen, S; Jurcso, P

    2014-01-01

    CERN’s Accelerator Control System is built upon a large number of C, C++ and Java services that are required for daily operation of the accelerator complex. The knowledge of the internal state of these processes is essential for problem diagnostic as well as for constant monitoring for pre-failure recognition. The CMX library follows similar principles as JMX (Java Management Extensions) and provides similar monitoring capabilities for C and C++ applications. It allows registering and exposing runtime information as simple counters, floating point numbers or character data. This can be subsequently used by external diagnostics tools for checking thresholds, sending alerts or trending. CMX uses shared memory to ensure non-blocking read/update actions, which is an important requirement in real-time processes. This paper introduces the topic of monitoring C/C++ applications and presents CMX as a building block to achieve this goal.

  16. Application of remote debugging techniques in user-centric job monitoring

    International Nuclear Information System (INIS)

    Dos Santos, T; Mättig, P; Harenberg, T; Volkmer, F; Beermann, T; Kalinin, S; Ahrens, R; Wulff, N

    2012-01-01

    With the Job Execution Monitor, a user-centric job monitoring software developed at the University of Wuppertal and integrated into the job brokerage systems of the WLCG, job progress and grid worker node health can be supervised in real time. Imminent error conditions can thus be detected early by the submitter and countermeasures can be taken. Grid site admins can access aggregated data of all monitored jobs to infer the site status and to detect job misbehaviour. To remove the last 'blind spot' from this monitoring, a remote debugging technique based on the GNU C compiler suite was developed and integrated into the software; its design concept and architecture is described in this paper and its application discussed.

  17. Application for verification of monitor units of the treatment planning system

    International Nuclear Information System (INIS)

    Suero Rodrigo, M. A.; Marques Fraguela, E.

    2011-01-01

    Current estimates algorithms achieve acceptable degree of accuracy. However, operate on the basis of un intuitive models. It is therefore necessary to verify the calculation of monitor units of the treatment planning system (TPS) with those obtained by other independent formalisms. To this end, we have developed an application based on factorization formalism that automates the calculation of dose.

  18. Monitoring bentazone concentrations in the uppermost groundwater after late season applications

    NARCIS (Netherlands)

    Cornelese AA; Linden AMA vd; LBG

    1998-01-01

    The herbicide bentazone has been detected in groundwater in several monitoring programs with most of the findings possibly be related to applications early in the growth season. Because of a very low sorption constant bentazone can be transported in soil with the waterflow very easily. This means

  19. Mass Spectrometry for Research and Application in Therapeutic Drug Monitoring or Clinical and Forensic Toxicology.

    Science.gov (United States)

    Maurer, Hans H

    2018-04-30

    This paper reviews current applications of various hyphenated low- and high-resolution mass spectrometry techniques in the field of therapeutic drug monitoring and clinical/forensic toxicology in both research and practice. They cover gas chromatography, liquid chromatography, matrix-assisted laser desorption ionization, or paper spray ionization coupled to quadrupole, ion trap, time-of-flight, or Orbitrap mass analyzers.

  20. Development of neutron-monitor detectors applicable for energies up to 100 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Tatsuhiko; Endo, Akira; Yamaguchi, Yasuhiro; Kim, Eunjoo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Nakamura, Takashi [Tohoku Univ., Sendai, Miyagi (Japan)

    2003-03-01

    For the purpose of monitoring of neutron doses in high energy accelerator facilities, we have been developing neutron detectors which are applicable for neutron energies up to 100 MeV. The present paper reports characteristics of a phoswitch-type neutron detector which is composed of a liquid organic scintillator and {sup 6}Li+ZnS(Ag) sheets. (author)

  1. An application study for the class 1E digital control and monitoring system

    International Nuclear Information System (INIS)

    Hiroyuki Fukumitsu

    1998-01-01

    This paper presents an application study for the Class 1E digital control and monitoring system to the next Japanese plants, especially about MMIS. The system architecture of hardware and software is also introduced, which will explain the strategic plan for the necessary software verification and validation according to the latest requirement from Japanese regulatory guide. (author)

  2. Application of risk assessment techniques to microbial monitoring data: a South-African perspective

    CSIR Research Space (South Africa)

    Rodda, N

    1993-01-01

    Full Text Available (-1) and 5x10(-4) - 1x10(-2), respectively. A number of complicating factors were identified. Detection limits were high and volumes of water monitored were low. There was no information on viral pathogen removal during treatment. Application of risk...

  3. An artificial intelligence approach to onboard fault monitoring and diagnosis for aircraft applications

    Science.gov (United States)

    Schutte, P. C.; Abbott, K. H.

    1986-01-01

    Real-time onboard fault monitoring and diagnosis for aircraft applications, whether performed by the human pilot or by automation, presents many difficult problems. Quick response to failures may be critical, the pilot often must compensate for the failure while diagnosing it, his information about the state of the aircraft is often incomplete, and the behavior of the aircraft changes as the effect of the failure propagates through the system. A research effort was initiated to identify guidelines for automation of onboard fault monitoring and diagnosis and associated crew interfaces. The effort began by determining the flight crew's information requirements for fault monitoring and diagnosis and the various reasoning strategies they use. Based on this information, a conceptual architecture was developed for the fault monitoring and diagnosis process. This architecture represents an approach and a framework which, once incorporated with the necessary detail and knowledge, can be a fully operational fault monitoring and diagnosis system, as well as providing the basis for comparison of this approach to other fault monitoring and diagnosis concepts. The architecture encompasses all aspects of the aircraft's operation, including navigation, guidance and controls, and subsystem status. The portion of the architecture that encompasses subsystem monitoring and diagnosis was implemented for an aircraft turbofan engine to explore and demonstrate the AI concepts involved. This paper describes the architecture and the implementation for the engine subsystem.

  4. Compliance monitoring in business processes: Functionalities, application, and tool-support.

    Science.gov (United States)

    Ly, Linh Thao; Maggi, Fabrizio Maria; Montali, Marco; Rinderle-Ma, Stefanie; van der Aalst, Wil M P

    2015-12-01

    In recent years, monitoring the compliance of business processes with relevant regulations, constraints, and rules during runtime has evolved as major concern in literature and practice. Monitoring not only refers to continuously observing possible compliance violations, but also includes the ability to provide fine-grained feedback and to predict possible compliance violations in the future. The body of literature on business process compliance is large and approaches specifically addressing process monitoring are hard to identify. Moreover, proper means for the systematic comparison of these approaches are missing. Hence, it is unclear which approaches are suitable for particular scenarios. The goal of this paper is to define a framework for Compliance Monitoring Functionalities (CMF) that enables the systematic comparison of existing and new approaches for monitoring compliance rules over business processes during runtime. To define the scope of the framework, at first, related areas are identified and discussed. The CMFs are harvested based on a systematic literature review and five selected case studies. The appropriateness of the selection of CMFs is demonstrated in two ways: (a) a systematic comparison with pattern-based compliance approaches and (b) a classification of existing compliance monitoring approaches using the CMFs. Moreover, the application of the CMFs is showcased using three existing tools that are applied to two realistic data sets. Overall, the CMF framework provides powerful means to position existing and future compliance monitoring approaches.

  5. Factors Affecting Faculty Web Portal Usability

    Science.gov (United States)

    Bringula, Rex P.; Basa, Roselle S.

    2011-01-01

    The study investigated the factors that might significantly affect web portal usability. Results of the study were intended to serve as inputs for faculty web portal development of the University of the East-Manila. Descriptive statistics utilized questionnaire data from 82 faculty members. The data showed that most of the respondents were…

  6. Portal circulation aneurysms: two case reviews

    International Nuclear Information System (INIS)

    Perret, W. L.; Silva, A de.; Elzarka, A.; Schelleman, A.

    2007-01-01

    Venous aneurysms of the superior mesenteric vein and portal vein are an uncommon occurrence and often an incidental finding. They can also be associated with hepatocellular disease and portal hypertension. We present CT and ultrasound findings of these entities. The management of venous aneurysms is generally conservative with serial imaging

  7. Optimization of portal placement for endoscopic calcaneoplasty

    NARCIS (Netherlands)

    van Sterkenburg, Maayke N.; Groot, Minke; Sierevelt, Inger N.; Spennacchio, Pietro A.; Kerkhoffs, Gino M. M. J.; van Dijk, C. Niek

    2011-01-01

    The purpose of our study was to determine an anatomic landmark to help locate portals in endoscopic calcaneoplasty. The device for optimal portal placement (DOPP) was developed to measure the distance from the distal fibula tip to the calcaneus (DFC) in 28 volunteers to determine the location of the

  8. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    OpenAIRE

    Madhusudhan, KS; Agrawal, Nikhil; Srivastava, Deep N; Pal, Sujoy; Gupta, Arun K

    2013-01-01

    Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, su...

  9. Isocurvature constraints on portal couplings

    Energy Technology Data Exchange (ETDEWEB)

    Kainulainen, Kimmo; Nurmi, Sami; Vaskonen, Ville [Department of Physics, University of Jyväskylä, P.O.Box 35 (YFL), FI-40014 University of Jyväskylä (Finland); Tenkanen, Tommi; Tuominen, Kimmo, E-mail: kimmo.kainulainen@jyu.fi, E-mail: sami.t.nurmi@jyu.fi, E-mail: tommi.tenkanen@helsinki.fi, E-mail: kimmo.i.tuominen@helsinki.fi, E-mail: ville.vaskonen@jyu.fi [Department of Physics, University of Helsinki P.O. Box 64, FI-00014, Helsinki (Finland)

    2016-06-01

    We consider portal models which are ultraweakly coupled with the Standard Model, and confront them with observational constraints on dark matter abundance and isocurvature perturbations. We assume the hidden sector to contain a real singlet scalar s and a sterile neutrino ψ coupled to s via a pseudoscalar Yukawa term. During inflation, a primordial condensate consisting of the singlet scalar s is generated, and its contribution to the isocurvature perturbations is imprinted onto the dark matter abundance. We compute the total dark matter abundance including the contributions from condensate decay and nonthermal production from the Standard Model sector. We then use the Planck limit on isocurvature perturbations to derive a novel constraint connecting dark matter mass and the singlet self coupling with the scale of inflation: m {sub DM}/GeV ∼< 0.2λ{sub s}{sup 3/8} ( H {sub *}/10{sup 11} GeV){sup −3/2}. This constraint is relevant in most portal models ultraweakly coupled with the Standard Model and containing light singlet scalar fields.

  10. Idiopathic noncirrhotic portal hypertension: current perspectives.

    Science.gov (United States)

    Riggio, Oliviero; Gioia, Stefania; Pentassuglio, Ilaria; Nicoletti, Valeria; Valente, Michele; d'Amati, Giulia

    2016-01-01

    The term idiopathic noncirrhotic portal hypertension (INCPH) has been recently proposed to replace terms, such as hepatoportal sclerosis, idiopathic portal hypertension, incomplete septal cirrhosis, and nodular regenerative hyperplasia, used to describe patients with a hepatic presinusoidal cause of portal hypertension of unknown etiology, characterized by features of portal hypertension (esophageal varices, nonmalignant ascites, porto-venous collaterals), splenomegaly, patent portal, and hepatic veins and no clinical and histological signs of cirrhosis. Physicians should learn to look for this condition in a number of clinical settings, including cryptogenic cirrhosis, a disease known to be associated with INCPH, drug administration, and even chronic alterations in liver function tests. Once INCPH is clinically suspected, liver histology becomes mandatory for the correct diagnosis. However, pathologists should be familiar with the histological features of INCPH, especially in cases in which histology is not only requested to exclude liver cirrhosis.

  11. ClusterControl: a web interface for distributing and monitoring bioinformatics applications on a Linux cluster.

    Science.gov (United States)

    Stocker, Gernot; Rieder, Dietmar; Trajanoski, Zlatko

    2004-03-22

    ClusterControl is a web interface to simplify distributing and monitoring bioinformatics applications on Linux cluster systems. We have developed a modular concept that enables integration of command line oriented program into the application framework of ClusterControl. The systems facilitate integration of different applications accessed through one interface and executed on a distributed cluster system. The package is based on freely available technologies like Apache as web server, PHP as server-side scripting language and OpenPBS as queuing system and is available free of charge for academic and non-profit institutions. http://genome.tugraz.at/Software/ClusterControl

  12. New Technology and Experimental Study on Snow-Melting Heated Pavement System in Tunnel Portal

    Directory of Open Access Journals (Sweden)

    Jinxing Lai

    2015-01-01

    Full Text Available In recent years, with the rapid growth of economy and sharp rise of motor vehicles in China, the pavement skid resistance in tunnel portals has become increasingly important in cold region. However, the deicing salt, snow removal with machine, and other antiskid measures adopted by highway maintenance division have many limitations. To improve the treatment effect, we proposed a new snow-melting approach employing electric heat tracing, in which heating cables are installed in the structural layer of road. Through the field experiment, laboratory experiment, and numerical investigation, structure type, heating power, and preheating time of the flexible pavement heating system in tunnel portal were systematically analyzed, and advantages of electric heat tracing technology in improving the pavement skid resistance in tunnel portal were also presented. Therefore, such new technology, which offers new snow-melting methods for tunnel portal, bridge, mountainous area, and large longitudinal slope in cold region, has promising prospect for extensive application.

  13. SAR interferometry applications on active volcanoes. State of the art and perspectives for volcano monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Puglisi, G.; Coltelli, M. [Istituto Nazionale di Geofisica e Vulcanologia, Catania (Italy)

    2001-02-01

    In this paper the application of the Synthetic Aperture Radar Interferometry (INSAR) on volcanology is analysed. Since it is not a real novelty among the different applications of INSAR in Earth Observation activities, at the beginning of this paper it is analysed the state of the art of the researches in this field. During the discussion, the point of view of volcanologists is favoured because it is considered that the first applications were often badly aimed. Consequently, the initial INSAR performances in volcanology were overrated with respect to the real capabilities of this technique. This fact lead to discover some unexpected limitations in INSAR usage in volcano monitoring, but, at the same time, spurred on scientists to overcome these drawbacks. The results achieved recently allow to better apply SAR to volcanology; in the paper a possible operative work-plan aimed at introducing INSAR in the volcano monitoring system is presented.

  14. Reverse Engineering and Software Products Reuse to Teach Collaborative Web Portals: A Case Study with Final-Year Computer Science Students

    Science.gov (United States)

    Medina-Dominguez, Fuensanta; Sanchez-Segura, Maria-Isabel; Mora-Soto, Arturo; Amescua, Antonio

    2010-01-01

    The development of collaborative Web applications does not follow a software engineering methodology. This is because when university students study Web applications in general, and collaborative Web portals in particular, they are not being trained in the use of software engineering techniques to develop collaborative Web portals. This paper…

  15. A Smart Voltage and Current Monitoring System for Three Phase Inverters Using an Android Smartphone Application.

    Science.gov (United States)

    Mnati, Mohannad Jabbar; Van den Bossche, Alex; Chisab, Raad Farhood

    2017-04-15

    In this paper, a new smart voltage and current monitoring system (SVCMS) technique is proposed. It monitors a three phase electrical system using an Arduino platform as a microcontroller to read the voltage and current from sensors and then wirelessly send the measured data to monitor the results using a new Android application. The integrated SVCMS design uses an Arduino Nano V3.0 as the microcontroller to measure the results from three voltage and three current sensors and then send this data, after calculation, to the Android smartphone device of an end user using Bluetooth HC-05. The Arduino Nano V3.0 controller and Bluetooth HC-05 are a cheap microcontroller and wireless device, respectively. The new Android smartphone application that monitors the voltage and current measurements uses the open source MIT App Inventor 2 software. It allows for monitoring some elementary fundamental voltage power quality properties. An effort has been made to investigate what is possible using available off-the-shelf components and open source software.

  16. Dark Fiber and Distributed Acoustic Sensing: Applications to Monitoring Seismicity and Near-Surface Properties

    Science.gov (United States)

    Ajo Franklin, J. B.; Lindsey, N.; Dou, S.; Freifeld, B. M.; Daley, T. M.; Tracy, C.; Monga, I.

    2017-12-01

    "Dark Fiber" refers to the large number of fiber-optic lines installed for telecommunication purposes but not currently utilized. With the advent of distributed acoustic sensing (DAS), these unused fibers have the potential to become a seismic sensing network with unparalleled spatial extent and density with applications to monitoring both natural seismicity as well as near-surface soil properties. While the utility of DAS for seismic monitoring has now been conclusively shown on built-for-purpose networks, dark fiber deployments have been challenged by the heterogeneity of fiber installation procedures in telecommunication as well as access limitations. However, the potential of telecom networks to augment existing broadband monitoring stations provides a strong incentive to explore their utilization. We present preliminary results demonstrating the application of DAS to seismic monitoring on a 20 km run of "dark" telecommunications fiber between West Sacramento, CA and Woodland CA, part of the Dark Fiber Testbed maintained by the DOE's ESnet user facility. We show a small catalog of local and regional earthquakes detected by the array and evaluate fiber coupling by using variations in recorded frequency content. Considering the low density of broadband stations across much of the Sacramento Basin, such DAS recordings could provide a crucial data source to constrain small-magnitude local events. We also demonstrate the application of ambient noise interferometry using DAS-recorded waveforms to estimate soil properties under selected sections of the dark fiber transect; the success of this test suggests that the network could be utilized for environmental monitoring at the basin scale. The combination of these two examples demonstrates the exciting potential for combining DAS with ubiquitous dark fiber to greatly extend the reach of existing seismic monitoring networks.

  17. GridICE: monitoring the user/application activities on the grid

    International Nuclear Information System (INIS)

    Aiftimiei, C; Pra, S D; Andreozzi, S; Fattibene, E; Misurelli, G; Cuscela, G; Donvito, G; Dudhalkar, V; Maggi, G; Pierro, A; Fantinel, S

    2008-01-01

    The monitoring of the grid user activity and application performance is extremely useful to plan resource usage strategies particularly in cases of complex applications. Large VOs, such as the LHC VOs, do their monitoring by means of dashboards. Other VOs or communities, like for example the BioinfoGRID one, are characterized by a greater diversification of the application types: so the effort to provide a dashboard like monitor is particularly heavy. The main theme of this paper is to show the improvements introduced in GridICE, a web tool built to provides an almost complete grid monitoring. These recent improvements allows GridICE to provide new reports on the resources usage with details of the VOMS groups, roles and users. By accessing the GridICE web pages, the grid user can get all information that is relevant to keep track of his activity on the grid. In the same way, the activity of a VOMS group can be distinguished from the activity of the entire VO. In this paper we briefly talk about the features and advantages of this approach and, after discussing the requirements, we describe the software solutions, middleware and prerequisite to manage and retrieve the user's credentials

  18. Applications of Advanced Technology for Monitoring Forest Carbon to Support Climate Change Mitigation

    Science.gov (United States)

    Birdsey, R.; Hurtt, G. C.; Dubayah, R.; Hagen, S. C.; Vargas, R.; Nehrkorn, T.; Domke, G. M.; Houghton, R. A.

    2015-12-01

    Measurement, Reporting, and Verification (MRV) is a broad concept guiding the application of monitoring technology to the needs of countries or entities for reporting and verifying reductions in greenhouse gas emissions or increases in greenhouse gas sinks. Credibility, cost-effectiveness, and compatibility are important features of global MRV efforts that can support implementation of climate change mitigation programs such as Reducing Emissions from Deforestation and Forest Degradation and Sustainable Forest Management (REDD+). Applications of MRV technology may be tailored to individual country circumstances following guidance provided by the Intergovernmental Panel on Climate Change; hence, there is no single approach that is uniquely viable but rather a range of ways to integrate new MRV methods. MRV technology is advancing rapidly with new remote sensing and advanced measurement of atmospheric CO2, and in situ terrestrial and ocean measurements, coupled with improvements in data analysis, modeling, and assessing uncertainty. Here we briefly summarize some of the most application-ready MRV technologies being developed under NASA's Carbon Monitoring System (CMS) program, and illustrate how these technologies may be applied for monitoring forests using several case studies that span a range of scales, country circumstances, and stakeholder reporting requirements. We also include remarks about the potential role of advanced monitoring technology in the context of the global climate accord that is expected to result from the 21st session of the Conference of the Parties to the United Nations Framework Convention on Climate Change, which is expected to take place in December 2015, in Paris, France.

  19. Access High Quality Imagery from the NOAA View Portal

    Science.gov (United States)

    Pisut, D.; Powell, A. M.; Loomis, T.; Goel, V.; Mills, B.; Cowan, D.

    2013-12-01

    NOAA curates a vast treasure trove of environmental data, but one that is sometimes not easily accessed, especially for education, outreach, and media purposes. Traditional data portals in NOAA require extensive knowledge of the specific names of observation platforms, models, and analyses, along with nomenclature for variable outputs. A new website and web mapping service (WMS) from NOAA attempts to remedy such issues. The NOAA View data imagery portal provides a seamless entry point into data from across the agency: satellite, models, in-situ analysis, etc. The system provides the user with ability to browse, animate, and download high resolution (e.g., 4,000 x 2,000 pixel) imagery, Google Earth, and even proxy data files. The WMS architecture also allows the resources to be ingested into other software systems or applications.

  20. A Semantically Enabled Portal for Facilitating the Public Service Provision

    Science.gov (United States)

    Loutas, Nikolaos; Giantsiou, Lemonia; Peristeras, Vassilios; Tarabanis, Konstantinos

    During the past years, governments have made significant efforts to improve both their internal processes and the services that they provide to citizens and businesses. These led to several successful e-Government applications (e.g., see www.epractice.eu). One of the most popular tools that was used by governments in order to modernize their services and make them accessible is e-Government portals, e.g., (Drigas et al. 2005), (Fang 2002). The main goals of such portals are: To make available complete, easy to understand, and structured information about public services and public administration's modus operandi, which will assist citizens during the service provision process. To facilitate the electronic execution of public services. Nevertheless, most of such efforts did not succeed. Gartner argues that most e-Government strategies have not achieved their objectives and have failed to trigger sustainable government transformation to greater efficiency and citizen-centricity (DiMaio 2007).