WorldWideScience

Sample records for portable nda equipment

  1. CSER 94-015: New portable NDA equipment for use in SNM audits

    Energy Technology Data Exchange (ETDEWEB)

    Hess, A.L.

    1994-12-12

    A criticality safety review is presented for the use of two portable NDA detectors from Los Alamos during an IAEA inspection of the SNM at PFP. The units are an Active Well Coincidence Counter (AWCC) and a High Level Neutron Coincidence Counter (HLNCC). Approval for their employment is based on the inherent safety of the containers to be assayed, one at a time, and because their designs conform with the acceptability criteria which allow the other NDA detectors currently employed at the facility.

  2. EMR Measurements on NDA Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Macdonell, Alexander Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meierbachtol, Krista Cruse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Evans, James Walter Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mayo, Douglas R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

  3. Design and construction of the Portable Industrial X-Ray Equipment

    International Nuclear Information System (INIS)

    Nguyen Phuc; Nguyen Van Si; Le Tien Quan; Trinh Anh Tuan; Nguyen Manh Hung; Trinh Dinh Tuong

    2011-01-01

    The main purposes of the project are the supporting to design and construction of the Portable Industrial X-Ray Equipment; with the accuracy ±2% of Output High Voltage 200 kV and Tube current 5 mA. The Equipment is composed of control unit, X-ray generator, and power cable, connection cable. X-ray generator is assembling construction X-ray tube, H.V transformer together with gas insulation (SF6) are sealed up in aluminum bucked cabinet, fan and heat-sink are mounted in the end of X-ray generator as cooling, SF6 is a gas electrical performance to H.V. Alarm lamp is used to warn, flashing, show generating X-ray. Control unit is box construction. Four printed circuit boards (PCB) and electronic device are mounted in it. All operating buttons switches and displays are equipped on the panel. We have completed to design and construct the Portable Industrial X-Ray Equipment; and have tested the electronic parameters of all test points and the main parameters of equipment (the accuracy ±2% of Output High Voltage 200 kV and Tube current 5 mA). We also have successful used the Portable Industrial X-Ray Equipment to evaluate the welds in industry. (author)

  4. A portable nondestructive assay measurement control system

    International Nuclear Information System (INIS)

    Palmer, M.E.

    1984-01-01

    Portable nondestructive assay (NDA) of plutonium processing hoods, solvent extraction columns, glove boxes, filters, and other items is required for both nuclear materials accountability and criticality control purposes. The Plutonium Finishing Plant has hundreds of such items that require routine portable NDA measurement. Previous recordkeeping of NDA measurements consisted of boxes of papers containing results and notebooks containing notes for each item to be measured. If the notes for any item were lost, new measurement parameters had to be calculated for that item. As a result, subsequent measurements could no longer be directly compared with previous results for that item due to possible changes in measurement parameters. The new portable NDA management system keeps all the necessary information in a computerized data base. Technicians are provided with a computer-generated drawing of each item to be measured, which also contains comments, measurement points, measurement parameters, and a form for filling in the raw data. After the measurements are made, the technician uses the computer to calculate and print out the results

  5. Lithium-ion Battery Charge Methodologies Observed with Portable Electronic Equipment

    Science.gov (United States)

    Jeevarajan, Judith

    2009-01-01

    Commercial lithium-ion batteries in portable electronic equipment has been used by NASA for space applications since 1999. First battery that was certified for flight and flown for Shuttle use was the Canon BP 927 (2.7 Ah) battery pack. Since then, numerous portable equipment with li-ion batteries have been certified and flown and remain on-orbit for crew usage. Laptops (two generations with third one being worked on now) Camcorder Camera PDA 2 versions (second one being li-ion polymer cells) Satellite Phone Due to expense and time, certified batteries are used with different equipment with the help of adapters or by working with the manufacturer of the equipment to build the appropriate battery compartment and connector. Certified and dedicated chargers are available on Shuttle and on the ISS for safe charging.

  6. Non destructive assay (NDA) techniques

    International Nuclear Information System (INIS)

    Mafra Guidicini, Olga; Llacer, Carlos D.; Rojo, Marcelo

    2001-01-01

    In the IAEA Safeguards System the basic verification method used is nuclear material accountancy, with containment and surveillance as important complementary measures. If nuclear material accountancy is to be effective, IAEA inspectors have to make independent measurements to verify declared material quantities. Most of the equipment available to the inspectors is designed to measure gamma rays and/or neutrons emitted by various nuclear materials. Equipment is also available to measure the gross weight of an item containing nuclear material. These types of measurement techniques are generally grouped under the title of nondestructive assay (NDA). The paper describes the NDA techniques and instruments used to verify the total amount of nuclear material held at a nuclear facility. (author)

  7. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  8. Radiological security of portable equipment used in the industry

    International Nuclear Information System (INIS)

    Cateriano, M.A.

    2006-01-01

    The industrial meters with encapsulated sources are used intensely in the present time due to the economic benefits that generate. Their use in all the one world has been reflected in an improvement of the quality of the analyzed product and of one optimization of the production process, allowing to carry out these measurements and controls without interrupting the process and in non destructive form generating an energy saving in turn and of materials. Although these industrial meters are intrinsically safe for design in the portable meters their safety also is strongly governed in the strict pursuit of procedures and in the adequate personnel's training that operate these equipment. In the Argentine Republic in 2005 the Nuclear Regulatory Authority (RNA) had registered a quantity of 160 portable equipment. In the period 1995-2003, 2 incidents took place with these equipment one of them used to measure soils humidity of Troxler trademark containing a source of Am-241(Be) of 370 MBq and the remaining one also of Troxler trademark used to measure density and humidity of soils containing 2 sources of Cs-137 of 296 MBq and Am-241(Be) of 1.48 GBq respectively. The incidents were developed without relevant radiological implications had taken place. In this work those mentioned incidents are analyzed in order to determining the causes that originated the same ones, for this way to be able to elaborate recommendations with the purpose of to correct errors and to diminish the recurrence probability improving the safety in the use of these equipment. From the analyses of these incidents result that should put on more emphasis in the personnel training and the invigoration of the safety culture in the use of the industrial meters. Also a present panorama of the inventory of equipment, sources and users that possess these portable meters in the Argentine Republic is also presented. (Author)

  9. Tour of safeguards equipment van

    International Nuclear Information System (INIS)

    Smith, B.W.; Fager, J.E.

    1984-01-01

    Increasing use is being made of nondestructive assay instruments for identification and measurements of nuclear materials. Important advantages of NDA are: timeliness, portability, and ease of use. Recent development in computer systems and NDA allow for the integration of sample planning, control of NDA, and data analysis into one transportable system. This session acquainted the course participants with the use of mobile NDA safeguards measurement systems. This session considered the practical problems and the type of results that can be expected from field use of NDA instruments. An existing mobile safeguards system was used to demonstrate some of the differences between field and laboratory conditions

  10. An investigation of hydrogen storage methods for fuel cell operation with man-portable equipment

    Energy Technology Data Exchange (ETDEWEB)

    Browning, D [Defence Evaluation and Research Agency, Haslar (United Kingdom); Jones, P [Defence Evaluation and Research Agency, Haslar (United Kingdom); Packer, K [Defence Evaluation and Research Agency, Haslar (United Kingdom)

    1997-03-01

    Air breathing proton exchange membrane fuel cells (PEMFC) are being considered as a power source for man-portable equipment, such as army radios. In addition to the weight and volume of the fuel cell itself, the device producing hydrogen with which to fuel the cell is also of crucial importance. This paper describes a number of hydrogen storage methods and discusses their applicability to man-portable equipment. (orig.)

  11. Standard guide for the selection, training and qualification of nondestructive assay (NDA) personnel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide contains good practices for the selection, training, qualification, and professional development of personnel performing analysis, calibration, physical measurements, or data review using nondestructive assay equipment, methods, results, or techniques. The guide also covers NDA personnel involved with NDA equipment setup, selection, diagnosis, troubleshooting, or repair. Selection, training, and qualification programs based on this guide are intended to provide assurance that NDA personnel are qualified to perform their jobs competently. This guide presents a series of options but does not recommend a specific course of action.

  12. [Development of a medical equipment support information system based on PDF portable document].

    Science.gov (United States)

    Cheng, Jiangbo; Wang, Weidong

    2010-07-01

    According to the organizational structure and management system of the hospital medical engineering support, integrate medical engineering support workflow to ensure the medical engineering data effectively, accurately and comprehensively collected and kept in electronic archives. Analyse workflow of the medical, equipment support work and record all work processes by the portable electronic document. Using XML middleware technology and SQL Server database, complete process management, data calculation, submission, storage and other functions. The practical application shows that the medical equipment support information system optimizes the existing work process, standardized and digital, automatic and efficient orderly and controllable. The medical equipment support information system based on portable electronic document can effectively optimize and improve hospital medical engineering support work, improve performance, reduce costs, and provide full and accurate digital data

  13. A brief history of NDA at the IAEA

    International Nuclear Information System (INIS)

    Sprinkle, J.K.; Sinkule, B.J.; Hsue, S.-T.; Abhold, M.E.

    2001-01-01

    Nearly 30 years ago, the first portable nondestructive assay instrument, a SAM-II, was brought to Vienna for IAEA consideration. This initial foray into the usage of nondestructive assay (NDA) as an independent assessment tool has materialized into one of the important tools for IAEA inspections. NDA instruments have several inherent advantages for inspectors; their measurements generate no radioactive waste, provide immediate answers, do not require specialized operators, and can be either taken to the items to be measured (portable instruments), or the items for measurement can be brought to the instruments, such as can be applied in on-site IAEA laboratories or off-site IAEA lab at Siebersdorf. The SAM-II was a small, lightweight, battery-powered, gamma-ray instrument used for uranium enrichment measurements. It was also found to be usehl for locating nuclear material, distinguishing between uranium and plutonium, and determining the active length of items like fuel pins. However it was not well suited for determining the amount of bulk material present, except for small containers of low-density materials. A 6-sided neutron coincidence counter, easily disassembled so it could be shipped and carried by airplane, was developed for bulk measurements of plutonium. The HLNCC (High Level Neutron Coincidence Counter) was immediately useful for quantitative measurements of pure plutonium oxide. However, the IAEA had to make a trade-off between the ease of use of NDA instruments on-site, and the problems of obtaining small samples for shipment to an independent lab for more accurate analysis. NDA does not create radioactive waste, so as waste handling has become more cautious and more regulated, NDA looks better and better. After acceptance of NDA by the IAEA for routine use, the follow-up question was naturally, 'How much better can this measurement be made?' The Program for Technical Assistance to IAEA Safeguards (POTAS) supported multiple and varied efforts in this

  14. IAEA experience with authentication of in-plant NDA instrumentation

    International Nuclear Information System (INIS)

    Augustson, R.H.; Dermendjiev, E.

    1983-01-01

    The paper discusses IAEA experience with permanently installed measuring equipment, i.e. in-plant NDA instrumentation, which often has advantages over portable equipment, such as improved accuracy, automated sample handling and data collection, and capacity for higher throughput. In some cases, in-plant equipment is the only means of making a field measurement. However, the use of in-plant equipment requires an additional set of inspector procedures to ensure that the instrument is working correctly and has not been tampered with. This process of verifying instrument performance is called authentication. General guidelines for approaches to authentication have been studied and formulated by an IAEA Advisory Group Meeting held in November 1981. Procedures for specific instruments have been developed in some cases with the help of national support programmes. The field application of authentication is accomplished by incorporating specific actions into inspection procedures. Results are written down as part of the working papers and included in the final inspection report. For quantitative checks such as measurement of a working standard the results are sent along with the inspection measurements to the Agency for inclusion in the safeguards data base. The in-plant equipment may be owned by the facility, a State, a safeguards organization or the Agency. In each case, the use of the in-plant equipment will necessitate additional interactions between facility operator and inspector, in order to judge the impact on plant operation, and understand what is being measured and what can go wrong. The paper discusses the IAEA's experience gained in the field application of authentication procedures for instrument systems such as weighing and volume measuring devices, rod scanners, neutron activation systems and K-edge densitometers

  15. New portability for in situ gamma-ray spectrometry from commercially available equipment

    International Nuclear Information System (INIS)

    Stanford, N.; Laurenzo, E.L.; McCurdy, D.E.

    1984-01-01

    In situ gamma-ray spectrometry has been employed by the staff of the Yankee Atomic Environmental Laboratory on a routine basis for more than five years. The original in situ gamma-ray spectrometry methodology was adopted from the techniques developed at the DOE Environmental Measurements Laboratory (Beck, DeCampo, and Gogolak 1972). The system consisted of a 110 cm 3 Ge(Li) detector in the vertical configuration in conjunction with typical laboratory nuclear instrumentation, as well as a medium-sized desktop computer, printer and disk drive. The equipment was transported in a small van having a shock-mounted cabinet and gasoline generator as an electrical power source. Recent availability of miniaturized spectrometry systems and powerful portable computers has enabled the upgrading of the 1977 vintage equipment to a system which is truly portable, light weight, compact and more reliable. The system to be described utilizes a portable intrinsic germanium detector, a small, 4096 channel pulse height analyzer (MCA) with anscillary components and a 24K, Hewlett Packard HP-75 computer with a small tape drive. When the equipment is used in the field, the system has enough capability to acquire and store a full 4096 channel gamma-ray spectrum and calculate the soil concentrations (pCi/g) and/or external radiation exposure rates for the commonly found naturally occurring, long-lived atmospheric nuclear weapons testing and nuclear power plant radionuclides. Subsequent data transfer to a larger desktop computer via available interfacing at the laboratory enables a full peak search and a more extensive evaluation of the data in order to calculate the soil concentrations and/or external radiation exposure rates for a selected 25 radionuclides. Experiences from the first season of operation are discussed

  16. THE SITE DEMONSTRATION OF CHEMFIX SOLIDIFICATION/ STABILIZATION PROCESS AT THE PORTABLE EQUIPMENT SALVAGE COMPANY SITE

    Science.gov (United States)

    A demonstration of the GHEMFIX solidification/stabilization process was conducted under the United States Environmental Protection Agency`s (EPA) Superfund Innovative Technology Evaluation (SITE) program. The demonstration was conducted in March 1989, at the Portable Equipment Sa...

  17. Development of a portable equipment for identification of radionuclides

    International Nuclear Information System (INIS)

    Farias, Marcos Santana; Carvalho, Paulo Victor R. de; Nedjah, Nadia; Mourelle, Luiza de Macedo

    2014-01-01

    The rapid and automatic identification of radionuclides present in a radioactive sample detected in the field, is information that helps in decision making. In areas of high traffic of people and materials, such as ports and airports as well as at major events, radiation monitoring, together with the identification of the radionuclide, it is advisable within protective standards to the public. The correct identification of radionuclides depends on the ability to determine whether specific peaks energy sources are present in the spectrum of gamma radiation sources. Radionuclides can be identified by these energy characteristics in the sense that the energy value associated with these peaks in the spectrum corresponds to the radiation sources present in the sample. There are many methods that can be used for automatic identification of radionuclides. Most of them are based on software algorithms for the detection of peaks in the energy spectrum. Processing time of these tasks can be very long for applications requiring quick responses, as in equipment portable. A dedicated digital hardware offers better performance for tasks with high processing demand like this. This work shows the development of a handle Portable radionuclides based on a digital hardware solution using a FPGA (Field Programmable Gate Array) for implementing a clustering algorithm for the detection of energy peaks. (author)

  18. Development of portable X-ray diffractometer equipped with X-ray fluorescence spectrometer and its application to archaeology

    International Nuclear Information System (INIS)

    Yamashita, Daisuke; Ishizaki, Atsushi; Uda, Masayuki

    2009-01-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to obtain a diffraction pattern and a fluorescence spectrum in air from one and the same small area of a specimen. The reason why the portable XRD with an XRF spectrometer was specially designed for archaeology may be understood from the following facts: (1) some objects exhibited in museums are not allowed to be transferred from the open air to a vacuum, even if their volumes are small; (2) some objects are very difficult to move from their original sites; (3) some parts of exhibits are extremely fragile and cannot be examined in a vacuum; and (4) information on the chemical composition and structure from the same area of an object offers a better understanding of the constitutive materials of the object. Some examples of the use of a portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer in the field are also introduced. Experimental results of Sho-kannon, Snew's mask and Tutankhamun's golden mask are shown here. (author)

  19. 46 CFR 108.651 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Portable magazine chests. 108.651 Section 108.651... AND EQUIPMENT Equipment Markings and Instructions § 108.651 Portable magazine chests. Each portable magazine chest must be marked: “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP LIGHTS AND FIRE AWAY” in letters at...

  20. Elements of nondestructive assay (NDA) technology

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This session provides an introduction to nondestructive assay methods and instruments as they are applied to nuclear safeguards. The purpose of the sessions is to enable participants to: (1) discuss the general principles and major applications of NDA; (2) describe situations in which NDA is particularly useful for nuclear safeguards purposes; (3) distinguish between various passive and active gamma-ray and neutron NDA methods; (4) describe several NDA instruments that measure gamma rays, and identify assay situations particularly suited to gamma-ray techniques; (5) describe several NDA instruments that measure neutrons, and identify assay situations particularly suited to neutron techniques; (6) discuss the role of calorimetry in the NDA of plutonium-bearing materials; and (7) compare the advantages and disadvantages of various NDA methods for different types of nuclear materials

  1. NDA for a new facility at SRP

    International Nuclear Information System (INIS)

    Studley, R.V.

    1987-01-01

    In 1980, plans were initiated to build a new facility to process high purity highly enriched 235 U. Interest in improving nuclear safeguards had been increasing in the previous few years. A basic objective of the design, therefore, included achievement of maximum performance in special nuclear material (SNM) accountability. A near-real-time accountability system with high accuracy assay measurements was developed for this purpose. Simultaneous design of facility, process equipment, and the accountability system allowed maximum integration of equipment and also permitted influence on process design and material characteristics to optimize accountability performance. This was an ideal situation in which to pursue maximum improvement in nondestructive assay (NDA) measurement performance. The resulting systems are described

  2. Design of the power sources for portable nuclear instruments

    International Nuclear Information System (INIS)

    Chen Wei; Fang Fang; Cui Yan; Cui Junliang; Zhou Wei

    2007-01-01

    How to charge for the portable equipments is always a topical subject aimed by people, the application of new type batteries and Battery Management brings great facility to people's life, the rechargeable battery for portable equipments is widely used in portable equipments, but the convenience of the charging power source is limited in special situation. This paper will discuss how to combining rechargeable battery with traditional alkaline batteries for charging the portable instruments. (authors)

  3. The development and application of portable speed tester for special equipment

    International Nuclear Information System (INIS)

    Lan Peng; Chen Ligang; Dai Sidan; Wang Huiting; Zhang Liangxu; Wang Lin

    2014-01-01

    Special equipment developed to meet the needs for research and industrial application of this stage, with the advantages of small size, high accuracy, long working hours, high reliability and intelligent portable speed tester. This paper describes the development and application of the tester. In terms of hardware, the tester use 'MCU + CPLD' to build the core of the system, and focus on high precision, low-power design, Software to increase their power electricity monitoring and filtering software anti-interference function. The tester can achieve high-precision measurement of the speed parameter, display measurement data in real time via the LCD display functions. Currently, the tester has been successfully achieved industrial application. (authors)

  4. Radiological security of portable equipment used in the industry; Seguridad radiologica de equipos portatiles utilizados en la industria

    Energy Technology Data Exchange (ETDEWEB)

    Cateriano, M.A. [Autoridad Regulatoria Nuclear, Av. Del Libertdor 8250, (C1429BNP), Ciudad Autonoma de Buenos Aires (Argentina)]. e-mail: mcateria@sede.arn.gov.ar

    2006-07-01

    The industrial meters with encapsulated sources are used intensely in the present time due to the economic benefits that generate. Their use in all the one world has been reflected in an improvement of the quality of the analyzed product and of one optimization of the production process, allowing to carry out these measurements and controls without interrupting the process and in non destructive form generating an energy saving in turn and of materials. Although these industrial meters are intrinsically safe for design in the portable meters their safety also is strongly governed in the strict pursuit of procedures and in the adequate personnel's training that operate these equipment. In the Argentine Republic in 2005 the Nuclear Regulatory Authority (RNA) had registered a quantity of 160 portable equipment. In the period 1995-2003, 2 incidents took place with these equipment one of them used to measure soils humidity of Troxler trademark containing a source of Am-241(Be) of 370 MBq and the remaining one also of Troxler trademark used to measure density and humidity of soils containing 2 sources of Cs-137 of 296 MBq and Am-241(Be) of 1.48 GBq respectively. The incidents were developed without relevant radiological implications had taken place. In this work those mentioned incidents are analyzed in order to determining the causes that originated the same ones, for this way to be able to elaborate recommendations with the purpose of to correct errors and to diminish the recurrence probability improving the safety in the use of these equipment. From the analyses of these incidents result that should put on more emphasis in the personnel training and the invigoration of the safety culture in the use of the industrial meters. Also a present panorama of the inventory of equipment, sources and users that possess these portable meters in the Argentine Republic is also presented. (Author)

  5. Emergency Mitigating Equipments - Post Fukushima Actions at Canadian Nuclear Power Plants - Portable AC Power Sources

    International Nuclear Information System (INIS)

    Vucetic, Jasmina; Kameswaran, R.

    2015-01-01

    In response to the Fukushima Daiichi NPP accident in 2011, the Canadian Nuclear Safety Commission set up a Task Force to evaluate operational, technical and regulatory implications on Canadian NPPs. While accepting that the risk from beyond-design-basis accidents (BDBA) at Canadian NPPs is very low, the Task Force identified a number of areas where additional improvements or confirmatory assessments would further enhance safety. As a result, a set of 36 Fukushima Action Items (FAIs) were assigned to the licensees. This paper focuses on the FAI related to electrical power system enhancements to address a total loss of all AC Power leading to a possibility of loss of heat sinks (i.e. Station Blackout). This required the licensees to implement the following: - Additional back up power supplied by portable diesel generator(s) to allow key instrumentation and control equipment and key electrical loads to remain operable; - Provisions for a storage and timely transportation and connection of the portable generator(s) to the applicable units; - Provisions for testing of the portable generator; - Provisions for fuelling of portable generators; - Provisions such as panels, receptacles, and connectors to quickly deploy the portable generators to plant system, and separate feeder cables route to avoid a common mode failure; - Load shedding strategy to extend the existing station's battery life to ensure that the connection of portable generators can be completed before the batteries are depleted; - Provisions to supply water to steam generators and Irradiated Fuel Bay using portable pumps; The paper will also provide a brief description of Electrical power systems of the Canadian NPPs designed to satisfy the high safety and reliability requirements for nuclear systems, which are based on the following: - 2 group design philosophy (Group 1 and Group 2 Electrical Power Systems) - 2 separate groups of onsite emergency generators (Class III Standby generators and Emergency

  6. Miravalles Geothermal Project: Portable Well Flow Test Equipment and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-05-01

    The well flow test program has been designed to facilitate the gathering of information, with portable test equipment, from various wells with regard to their capability of flow, the quality of steam produced at various back pressures, the composition and quantity of noncondensable gases flashed from the wells and the composition and quantity of solids in the well's liquid streams (brine). The test program includes procedures for obtaining the following basic flow data pertinent to the plant power cycle design: (1) Effluent steam and brine flows, pressures and temperatures; (2) Noncondensable and dissolved gas contents in steam and brine; (3) H{sub s}S content in gases formed; and (4) Solids content and chemical analysis of steam and brine.

  7. Elements of nondestructive assay (NDA) technology

    International Nuclear Information System (INIS)

    Hatcher, C.R.; Smith, H.

    1984-01-01

    A thorough introduction to nondestructive assay methods and instruments as they are applied to nuclear safeguards is presented. The general principles and major applications of NDA are discussed and situations in which NDA is particularly useful for nuclear safeguards purposes are described. Various passive and active γ-ray and neutron methods are examined and assay situations particularly suited to γ-ray techniques, or to neutron techniques are identified. The role of calorimetry in the NDA of plutonium-bearing materials is also discussed. The advantages and disadvantages of various NDA methods for different types of nuclear materials are mentioned

  8. 46 CFR 169.743 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Portable magazine chests. 169.743 Section 169.743... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.743 Portable magazine chests. Portable magazine chests must be marked in letters at least 3 inches high: “PORTABLE MAGAZINE CHEST...

  9. Use of Equipment Information System (EQUIS) to determine priority for purchasing safeguards equipment

    International Nuclear Information System (INIS)

    Silberberg, S.

    1988-01-01

    To manage its large world-wide inventory of safeguards equipment, the IAEA Safeguards department uses a computerized Equipment Information System (EQUIS). EQUIS data have been analyzed using Queueing Theory to determine if inventory is adequate to meet inspector demands and in those cases where it is inadequate, to indicate how many additional units should be procured. Results are tabulated for various types of non-destructive analysis (NDA) equipment. For equipment where there is a high turnover and hence a large amount of data, the analysis provides a powerful tool for assisting procurement decisions

  10. NRC licensing criteria for portable radwaste systems

    International Nuclear Information System (INIS)

    Hayes, J.J. Jr.

    1983-01-01

    The shortcomings of various components of the liquid and solid radwaste systems at nuclear power reactors has resulted in the contracting of the functions performed by these systems to various contractors who utilize portable equipment. In addition, some streams, for which treatment was not originally anticipated, have been processed by portable equipment. The NRC criteria applicable to portable liquid and solid radwaste systems is presented along with discussion on what is required to provide an adequate 10 CFR Part 50.59 review for those situations where changes are made to an existing system. The criteria the NRC is considering for facilities which may intend to utilize portable incinerators is also presented

  11. ARIES NDA Robot operators' manual

    International Nuclear Information System (INIS)

    Scheer, N.L.; Nelson, D.C.

    1998-05-01

    The ARIES NDA Robot is an automation device for servicing the material movements for a suite of Non-destructive assay (NDA) instruments. This suite of instruments includes a calorimeter, a gamma isotopic system, a segmented gamma scanner (SGS), and a neutron coincidence counter (NCC). Objects moved by the robot include sample cans, standard cans, and instrument plugs. The robot computer has an RS-232 connection with the NDA Host computer, which coordinates robot movements and instrument measurements. The instruments are expected to perform measurements under the direction of the Host without operator intervention. This user's manual describes system startup, using the main menu, manual operation, and error recovery

  12. Pre-Columbian alloys from the royal tombs of Sipan; energy dispersive X-ray fluorescence analysis with a portable equipment

    International Nuclear Information System (INIS)

    Cesareo, R.; Calza, C.; Dos Anjos, M.; Lopes, R.T.; Bustamante, A.; Fabian S, J.; Alva, W.; Chero Z, L.

    2010-01-01

    On the north coast of present-day Peru flourished approximately between 50 and 700 AD, the Moche civilization. It was an advanced culture and the Moche were sophisticated metalsmiths, so that they are considered as the finest producers of jewels and artefacts of the region. The Moche metalworking ability was impressively demonstrated by the objects discovered by Walter Alva and coworkers in 1987, in the excavations of the 'Tumbas Reales de Sipan'. About 50 metal objects from these excavations, now at the namesake Museum, in Lambayeque, north of Peru, were analyzed with a portable equipment using energy-dispersive X-ray fluorescence. This portable equipment is mainly composed of a small size X-ray tube and a thermoelectrically cooled X-ray detector. Standard samples of gold and silver alloys were employed for quantitative analysis. It was determined that the analyzed artefacts from the 'Tumbas Reales de Sipan' are mainly composed of gold, silver and copper alloys, of gilded copper and of tumbaga, the last being a poor gold alloy enriched at the surface by depletion gilding, i.e. removing copper from the surface.

  13. 46 CFR 78.47-70 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Portable magazine chests. 78.47-70 Section 78.47-70... Fire and Emergency Equipment, Etc. § 78.47-70 Portable magazine chests. (a) Portable magazine chest shall be marked in letters of at least 3 inches high “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP LIGHTS AND...

  14. 46 CFR 97.37-47 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Portable magazine chests. 97.37-47 Section 97.37-47... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-47 Portable magazine chests. (a) Portable magazine chests shall be marked in letters at least 3 inches high: “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP...

  15. 46 CFR 196.37-47 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Portable magazine chests. 196.37-47 Section 196.37-47... Markings for Fire and Emergency Equipment, etc. § 196.37-47 Portable magazine chests. (a) Portable magazine chests shall be marked in letters at least 3 inches high: PORTABLE MAGAZINE CHEST — FLAMMABLE — KEEP...

  16. Weight/balance portable test equipment

    International Nuclear Information System (INIS)

    Whitlock, R.W.

    1994-01-01

    This document shows the general layout, and gives a part description for the weight/balance test equipment. This equipment will aid in the regulation of the leachate loading of tanker trucks. The report contains four drawings with part specifications. The leachate originates from lined trenches

  17. Portable equipment for determining ripeness in Hass avocado using a low cost color sensor

    Science.gov (United States)

    Toro, Jessica; Daza, Carolina; Vega, Fabio; Diaz, Leonardo; Torres, Cesar

    2015-08-01

    The avocado is a one climacteric fruit that not ripe on the tree because it produces a maturation inhibitor that passes the fruit through the pedicel, the ripening occurs naturally during storage or to be induced as required. In post-harvest ripening stage is basically determined by experience of the farmer or buyer. In this word us developed portable equipment for determining ripeness is hass avocado using a low cost sensor color sensor TC3200 and LCD for display result. The prototype read of RGB color frequencies of the sensor and estimates the stage of ripeness in fourth different stages in post-harvest ripening.

  18. Portable X-ray diffractometer equipped with XRF for archaeometry

    Science.gov (United States)

    Uda, M.; Ishizaki, A.; Satoh, R.; Okada, K.; Nakajima, Y.; Yamashita, D.; Ohashi, K.; Sakuraba, Y.; Shimono, A.; Kojima, D.

    2005-09-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to get a diffraction pattern and a fluorescence spectrum simultaneously in air from one and the same small area on a specimen. Here, diffraction experiments were performed in two modes, i.e. an angle rotation mode and an energy dispersive mode. In the latter a diffraction pattern and a fluorescence spectrum were simultaneously recorded in a short time, 100 s or less, on one display. The diffractometer was tested in the field to confirm its performance. Targets chosen for this purpose were a bronze mirror from the Eastern Han Dynasty (25-220), and a stupa and its pedestal which are part of the painted statue of "Tamonten holding a stupa" from the Heian Period (794-1192), enshrined in the Engyouji temple founded in 996. The bronze mirror was identified as a product of the Han Dynasty from its chemical composition and the existence of the δ phase in the Cu-Sn alloy. The stupa and its pedestal were decorated with gold powder and gold leaf, respectively. From the XRF data of the pedestal, the underlying layer of gold leaf seems to have been painted with emerald green.

  19. Portable X-ray diffractometer equipped with XRF for archaeometry

    International Nuclear Information System (INIS)

    Uda, M.; Ishizaki, A.; Satoh, R.; Okada, K.; Nakajima, Y.; Yamashita, D.; Ohashi, K.; Sakuraba, Y.; Shimono, A.; Kojima, D.

    2005-01-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to get a diffraction pattern and a fluorescence spectrum simultaneously in air from one and the same small area on a specimen. Here, diffraction experiments were performed in two modes, i.e. an angle rotation mode and an energy dispersive mode. In the latter a diffraction pattern and a fluorescence spectrum were simultaneously recorded in a short time, 100 s or less, on one display. The diffractometer was tested in the field to confirm its performance. Targets chosen for this purpose were a bronze mirror from the Eastern Han Dynasty (25-220), and a stupa and its pedestal which are part of the painted statue of 'Tamonten holding a stupa' from the Heian Period (794-1192), enshrined in the Engyouji temple founded in 996. The bronze mirror was identified as a product of the Han Dynasty from its chemical composition and the existence of the δ phase in the Cu-Sn alloy. The stupa and its pedestal were decorated with gold powder and gold leaf, respectively. From the XRF data of the pedestal, the underlying layer of gold leaf seems to have been painted with emerald green

  20. Pre-Columbian alloys from the royal tombs of Sipan; energy dispersive X-ray fluorescence analysis with a portable equipment

    Energy Technology Data Exchange (ETDEWEB)

    Cesareo, R. [Dip. di Matematica e Fisica, Universita di Sassari, via Vienna 2, 07100, Sassari (Italy)], E-mail: cesareo@uniss.it; Calza, C.; Dos Anjos, M.; Lopes, R.T. [Nuclear Instrumentation Laboratory, COPPE, Universidade Federal do Rio de Janeiro (Brazil); Bustamante, A.; Fabian S, J. [Universidad Nacional Mayor de San Marcos, Lima (Peru); Alva, W.; Chero Z, L. [Museo ' Tumbas Reales de Sipan' , Lambayeque (Peru)

    2010-04-15

    On the north coast of present-day Peru flourished approximately between 50 and 700 AD, the Moche civilization. It was an advanced culture and the Moche were sophisticated metalsmiths, so that they are considered as the finest producers of jewels and artefacts of the region. The Moche metalworking ability was impressively demonstrated by the objects discovered by Walter Alva and coworkers in 1987, in the excavations of the 'Tumbas Reales de Sipan'. About 50 metal objects from these excavations, now at the namesake Museum, in Lambayeque, north of Peru, were analyzed with a portable equipment using energy-dispersive X-ray fluorescence. This portable equipment is mainly composed of a small size X-ray tube and a thermoelectrically cooled X-ray detector. Standard samples of gold and silver alloys were employed for quantitative analysis. It was determined that the analyzed artefacts from the 'Tumbas Reales de Sipan' are mainly composed of gold, silver and copper alloys, of gilded copper and of tumbaga, the last being a poor gold alloy enriched at the surface by depletion gilding, i.e. removing copper from the surface.

  1. [Advances of portable electrocardiogram monitor design].

    Science.gov (United States)

    Ding, Shenping; Wang, Yinghai; Wu, Weirong; Deng, Lingli; Lu, Jidong

    2014-06-01

    Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.

  2. Design and fabrication of NDA standards

    International Nuclear Information System (INIS)

    Long, S.M.; Hsue, S.T.

    1996-01-01

    The Plutonium Facility, TA-55, at Los Alamos National Laboratory is currently producing NDA calibration standards used by various laboratories in the DOE complex. These NIST traceable standards have been produced to calibrate NDA instruments for accountability measurements used for resolving shipper/receiver differences, and for accountability in process residues and process waste. Standards are needed to calibrate various NDA (Non-destructive Assay) instruments such as neutron coincidence counters, gamma-ray counters, and calorimeters. These instruments measure various ranges of nuclear material being produced in the DOE nuclear community. Los Alamos National Laboratory has taken a lead role in fabrication of uranium and plutonium standards, along with other actinides such as neptunium and americium. These standards have been fabricated for several laboratories within the complex. This paper will summarize previous publications detailing the careful planning encompassing components such as precise weighing, destructive analysis, and the use of post fabrication NDA measurements to confirm that the standards meet all preliminary expectations before use in instrument calibration. The paper will also describe the specialized containers, diluents, and the various amount of nuclear materials needed to accommodate the calibration ranges of the instruments

  3. Los Alamos safeguards program overview and NDA in safeguards

    International Nuclear Information System (INIS)

    Keepin, G.R.

    1988-01-01

    Over the years the Los Alamos safeguards program has developed, tested, and implemented a broad range of passive and active nondestructive analysis (NDA) instruments (based on gamma and x-ray detection and neutron counting) that are now widely employed in safeguarding nuclear materials of all forms. Here very briefly, the major categories of gamma ray and neutron based NDA techniques, give some representative examples of NDA instruments currently in use, and cite a few notable instances of state-of-the-art NDA technique development. Historical aspects and a broad overview of the safeguards program are also presented

  4. Improvement of equipment needed for the detection and characterization of nuclear material and radioactive samples at borders

    International Nuclear Information System (INIS)

    Arlt, R.; Kovar, A.; Swoboda, M.; Beck, P.; Duftschmid, K.E.; Lewis, W.

    2001-01-01

    Nuclear radiation measurement instruments and devices for the detection and characterisation of nuclear material and radioactive isotopes at borders play a decisive role in the set of technical measures needed to deal with the problem of illicit trafficking. Therefore the availability of a range of devices with adequate performance at affordable prices is essential. The needed equipment can be classified into the following categories: Detection equipment (border monitors and radiation pagers); Hand held devices for neutron/gamma source search and in-field characterisation of radiation sources by customs inspectors; NDA (non-destructive assay) instruments for in-depth investigation of a seized item by experts either in the field or under laboratory conditions. Instruments and techniques, which use destructive assay methods, are not considered in this paper. The most recent overview on the performance of such instruments is given in the Final Report of ITRAP (Illicit Trafficking Radiation Detection Assessment Program). According to the findings of ITRAP, although in all above mentioned categories equipment is commercially available, deficiencies and shortcomings were identified. In this paper we describe our effort in addressing some of the most essential equipment problems, identified in ITRAP - the sensitivity of border monitors with respect to the detection of nuclear material and the performance and usability of hand held and portable devices needed for in-field characterisation of seized items by customs inspectors

  5. NDA National Graduate Programme 'nucleargraduates'

    International Nuclear Information System (INIS)

    Dawson, Carl

    2010-01-01

    The aim of this paper is to outline the NDA National Graduate Programme (nuclear graduates). The NDA has a remit under the Energy Act (2004) 'to maintain and develop the skills for decommissioning and nuclear clean-up'. Although current research is now being reviewed, there is significant evidence to suggest that the age profile in the Site Licence Companies is skewed towards older workers and there is likely to be a skill shortage in 3-5 years. As nuclear clean-up is a national issue; skill shortages also become a national issue in a very real sense. In addition, evidence suggests that the industry needs to be constantly challenged in order to achieve its targets for decommissioning. The NDA has a unique position under the Act. It is both a strategic overseer and direct employer. To this end the 'National Graduate Programme' is aligned to both the NDA's previous succession plans and the needs of the industry. Industry needs leadership that challenges the status quo and moves the UK nuclear industry to become best in class; Industry needs a dedicated to programme to address skills shortages and difficult to recruit areas such as, but not exclusively, estimators, schedulers, contract managers, site engineers, decommissioning technicians, safety monitors; The NDA has indicated a 'commercial and politically savvy' cohort is required to meet its own internal challenges and to ensure sustainability in its own workforce, and to be sensitive to the needs of customers and suppliers alike; Need to create a more diversified workforce in the nuclear industry and also plan for new skills evolving from research and development breakthroughs; Need to ensure that Tier 1, 2, 3 and 4 contractors invest in the leadership and skills for the future. World Class - delivery will be benchmarked against UK based multinational companies who operate in a global graduate attraction and development marketplace. The graduates targeted will be from leading institutions and will have a blend of

  6. Pre-Columbian alloys from the royal tombs of Sipán; energy dispersive X-ray fluorescence analysis with a portable equipment.

    Science.gov (United States)

    Cesareo, R; Calza, C; Dos Anjos, M; Lopes, R T; Bustamante, A; Fabian S, J; Alva, W; Chero Z, L

    2010-01-01

    On the north coast of present-day Peru flourished approximately between 50 and 700 AD, the Moche civilization. It was an advanced culture and the Moche were sophisticated metalsmiths, so that they are considered as the finest producers of jewels and artefacts of the region. The Moche metalworking ability was impressively demonstrated by the objects discovered by Walter Alva and coworkers in 1987, in the excavations of the "Tumbas Reales de Sipán". About 50 metal objects from these excavations, now at the namesake Museum, in Lambayeque, north of Peru, were analyzed with a portable equipment using energy-dispersive X-ray fluorescence. This portable equipment is mainly composed of a small size X-ray tube and a thermoelectrically cooled X-ray detector. Standard samples of gold and silver alloys were employed for quantitative analysis. It was determined that the analyzed artefacts from the "Tumbas Reales de Sipán" are mainly composed of gold, silver and copper alloys, of gilded copper and of tumbaga, the last being a poor gold alloy enriched at the surface by depletion gilding, i.e. removing copper from the surface. Copyright 2009 Elsevier Ltd. All rights reserved.

  7. Portable flash X-ray systems: applications and techniques

    International Nuclear Information System (INIS)

    Bryant, L.E.

    1976-01-01

    Three portable flash x-ray equipments are described, and applications such as jet and high explosive studies, bullet impact and lead casting experiments are given as well as techniques for triggering and protection of equipment and film

  8. Portable Power And Digital-Communication Units

    Science.gov (United States)

    Levin, Richard R.; Henry, Paul K.; Rosenberg, Leigh S.

    1992-01-01

    Conceptual network of electronic-equipment modules provides electrical power and digital radio communications at multiple sites not served by cables. System includes central communication unit and portable units powered by solar photovoltaic arrays. Useful to serve equipment that must be set up quickly at remote sites or buildings that cannot be modified to provide cable connections.

  9. NDA [nondestructive assay] training for new IAEA inspectors at Los Alamos

    International Nuclear Information System (INIS)

    Stewart, J.E.; Reilly, T.D.; Belew, W.; Woelfl, E.; Fager, J.

    1987-01-01

    The history of the evolution of nondestructive assay (NDA) training for international inspectors at Los Alamos is described. The current NDA training course for International Atomic Energy Agency inspectors is presented in terms of structure, content, and rationale. Results of inspector measurement exercises are given along with projections for future developments in NDA inspector training. 3 refs

  10. Genel Anestezi Altında Çocukta Diş Tedavisi

    OpenAIRE

    Gülhan, A.; Sandallı, N.

    2013-01-01

    ÖZETBu makalede çocuklarda genel anestezi altında diş tedavisinin koşulları anlatıldı ve normal tedavi koşulları sağlanamadığı takdirde, genel anesteziye başvurmanın yararlarına ve sakıncalarına değinildi. Genel anestezi indikasyonları sıralanarak, bunlar arasında en sık rastladığımız «Güç çocuklarım" genci anesteziye başvurmadan Önce hangi yollara başvurularak normal tedavinin deneneceğinden bahsedildi.Bir hastane ortamında genel anestezi altında çalışmaya karar verildikten sonra, bir a...

  11. R and D activities of the ESARDA NDA working group

    International Nuclear Information System (INIS)

    Guardini, S.; Bignan, G.

    1999-01-01

    The aim of this paper is to report the R and D activities of the ESARDA Working Group on Techniques and Standards for Non-Destructive Analysis (NDA), as well as to discuss the role and possibilities of the group in the modern R and D scenario in safeguards and non-proliferation. The main tasks of the ESARDA NDA Working have been identified as being to: Define needs for procedural standards and reference materials; Design and manage the production and characterisation of reference materials; Assess and contribute to improving the performances of NDA techniques; Set up and maintain a list of NDA instruments and methods currently used for Safeguards purposes; and, through the above activities, assist Operators and Safeguards Authorities in their duty of Safeguards implementation. Members and observers appointed to the working group represent plant operators, the nuclear industry, R and D laboratories, NDA instrument developers and both safeguards control authorities. The participation of major European plant operators and of the EURATOM Safeguards Directorate and IAEA has always been assured and contributes to the good outcome of the WG activities. The ongoing R and D activities of the NDA Working Group are: Monte Carlo performance intercomparisons; 242 Pu accuracy assessment and improvement; NDA Sampling errors; General NDA performance evaluations. Some milestones have recently been reached: The 242 Pu uncertainty improvement project is coming to an end with the issuing of a new isotopic correlation; The NCC 'reals' evaluation and the Monte Carlo round robin is producing its first results; The Uranium Enrichment Round Robin Exercise has been completed; The waste drum standards are being characterised and constructed: they will be available by spring 1998. The round robin amongst laboratories will then start: summer 1998. Future activities comprise, beside the above issues, technical problems linked with the new challenges posed by new regimes of safeguards and non

  12. Hydrogen in portable devices

    Energy Technology Data Exchange (ETDEWEB)

    Garche, J. [ZSW - Electrochemical Energy storage and energy Conversion Division, Baden Wuerttemberg (Germany); Stimmer, U. [Technische Universitaet, Muenchen (Germany); Friedrich, A.K. [ZAE Bayern (Germany); Fiedenhans' l, R. [Risoe National Lab., Materials Res. Dept., Roskilde (Denmark)

    2004-10-01

    Fuel cells were originally intended for use in power plants and vehicles. More recently, developers realised the possibility for building much smaller units and for lower prices per kilowatt than their larger relatives. This has led to a strong interest in developing small fuel cells. Small fuel cells could replace batteries in portable electronic equipment and internal combustion engines in portable generators. The upper limit for portable generators is about 5kW, mainly because of the weight of the fuel cell. The main applications for low-power fuel cells are mobile phones, personal digital assistants, laptop and notebook computers, cameras, medical equipment, military applications and other portable electronic devices. In comparison to batteries, fuel cells can supply much more power per unit volume or weight, though they have lower output voltages and are slower to respond to transients. Fuel cell types that are suitable for portable applications include: proton exchange membrane fuel cells (PEMFCs) using pure hydrogen, PEMFCs using hydrogen-rich gases from hydrocarbon or alcohol reforming, direct methanol fuel cells and, high-temperature fuel cells such as solid oxide fuel cells (SOFCs) and molten carbonate fuel cells (MCFCs) using hydrocarbons directly. Fuel cells for portable devices is becoming a niche, high-value market area which has good opportunities for a fast introduction of fuel cell technology and for the first consumer products in the electronic market can be expected within the coming year and is believed to grow rapidly thereafter. Danish industry is involved in the development of SOFC, PEMFC and DMFC fuel cells and the industry has in particular a strong position in system components and complete systems. An important area for Danish industry is system integration, where fuel cells and hydrogen technologies are implemented in electrical powered products. This is an area that is particular suited for small and medium sized enterprises and for

  13. Hydrogen in portable devices

    International Nuclear Information System (INIS)

    Garche, J.; Stimmer, U.; Friedrich, A.K.; Fiedenhans'l, R.

    2004-01-01

    Fuel cells were originally intended for use in power plants and vehicles. More recently, developers realised the possibility for building much smaller units and for lower prices per kilowatt than their larger relatives. This has led to a strong interest in developing small fuel cells. Small fuel cells could replace batteries in portable electronic equipment and internal combustion engines in portable generators. The upper limit for portable generators is about 5kW, mainly because of the weight of the fuel cell. The main applications for low-power fuel cells are mobile phones, personal digital assistants, laptop and notebook computers, cameras, medical equipment, military applications and other portable electronic devices. In comparison to batteries, fuel cells can supply much more power per unit volume or weight, though they have lower output voltages and are slower to respond to transients. Fuel cell types that are suitable for portable applications include: proton exchange membrane fuel cells (PEMFCs) using pure hydrogen, PEMFCs using hydrogen-rich gases from hydrocarbon or alcohol reforming, direct methanol fuel cells and, high-temperature fuel cells such as solid oxide fuel cells (SOFCs) and molten carbonate fuel cells (MCFCs) using hydrocarbons directly. Fuel cells for portable devices is becoming a niche, high-value market area which has good opportunities for a fast introduction of fuel cell technology and for the first consumer products in the electronic market can be expected within the coming year and is believed to grow rapidly thereafter. Danish industry is involved in the development of SOFC, PEMFC and DMFC fuel cells and the industry has in particular a strong position in system components and complete systems. An important area for Danish industry is system integration, where fuel cells and hydrogen technologies are implemented in electrical powered products. This is an area that is particular suited for small and medium sized enterprises and for

  14. Recent Advances in Portable Analytical Electromigration Devices

    Directory of Open Access Journals (Sweden)

    Ann Van Schepdael

    2016-01-01

    Full Text Available This article presents an overview of recent advances in the field of portable capillary electrophoresis and microchip electrophoresis equipment during the period 2013–Mid 2015. Instrumental achievements in the separation as well as the detection part of the equipment are discussed. Several applications from a variety of fields are described.

  15. Modern NDA needs at Savannah River Site

    International Nuclear Information System (INIS)

    Holt, S.H.

    1995-01-01

    As the missions within the nuclear weapons complex change, so do the accountability measurement needs. Non-Destructive Assay (NDA) measurements have played a key role in accounting for special nuclear materials (SNM), and as time goes on, more and more reliance is made on this type of measurement. Key questions NDA instrument designers ask are: Which isotopes are of interest? What matrix are they in? What other isotopes are present? What container configuration will it be measured through? What precision and accuracy is required? What level of resolution is required? At the Savannah River Site (SRS) the desire to make direct measurements of SNM isotopes has prompted the evaluation to these and other questions. This paper will outline the current NDA needs at SRS. The discussion includes the types of materials that require measurement ,including the very difficult waste measurements. The special challenges associated with these measurement efforts will also be discussed

  16. Session 31B - Panel: Opportunities in the UK with the Nuclear Decommissioning Authority (NDA)

    International Nuclear Information System (INIS)

    Benda, Gary; Hayes, David; Gorham, Ron; Wareing, Mark; Simper, Adrian; Selby, Terry

    2006-01-01

    The NDA participated in a panel session 31B on Wednesday afternoon starting at 3:15. The NDA is a non-departmental public body, set up in April 2005 under the Energy Act 2004 to take strategic responsibility for the UK's nuclear legacy. Details of their organization and history are located on their web site at www.nda.gov.uk. Also copies of their Power Point presentations made at WM'06 are available on their web site. Their core objective is to ensure that the 20 civil public sector nuclear sites under our ownership are decommissioned and cleaned up safely, securely, cost effectively and in ways that protect the environment for this and future generations. They lead the development of a unified and coherent decommissioning strategy, working in partnership with regulators and site licensees to achieve best value, optimum impact on local communities, and the highest environmental standards. The NDA's main task is the decommissioning and clean up of civil nuclear sites. If the Government decides it is necessary, however, the Energy Act 2004 allows the NDA to take responsibility for sites currently operated by, or on behalf of, the Ministry of Defence (MoD). Resources will then be transferred from the MoD to meet the costs of clean up. The NDA made a number of presentations to allow conference delegates the opportunity to understand some of the major aspects of their work and to interact with NDA staff. These included the following topics and gave opportunity for audience discussion: - A brief presentation to update on progress by the NDA; - Outline of low level waste management and the prioritisation process; - Discussion of the competition schedule related to low level waste management and the Drigg site. The following presentations and handout were delivered in various sessions of the conference as noted below and are available on their web page including the WM'06 Plenary Session presentation by Sir Anthony Cleaver, Chairman of the NDA. During Session 31B, the

  17. 21 CFR 330.11 - NDA deviations from applicable monograph.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false NDA deviations from applicable monograph. 330.11... EFFECTIVE AND NOT MISBRANDED Administrative Procedures § 330.11 NDA deviations from applicable monograph. A new drug application requesting approval of an OTC drug deviating in any respect from a monograph that...

  18. Interactive CD based training on NDA instruments for facility operators and international inspectors

    International Nuclear Information System (INIS)

    Horley, E.C.; Smith, H.A.

    1996-01-01

    Interactive multimedia training is rapidly becoming a popular and highly effective medium for learning. An interactive CD based training module on the Active Well Coincidence counter is being developed for on-site training at nuclear facility, including foreign facilities. The training module incorporates interactive text, graphics and video that demonstrate the operating principles, and the use and set-up of the instrument. The user is in control of the pace of learning and of the directions taken to acquire information based on personal need. By being in control, the user stays highly motivated. A mix of visuals (text and graphics), audio clips (in different languages), and video (with audio) clips also keeps the interest level high. Skill reviews and evaluations can be incorporated into the training to provide feedback to the student. In addition, general background information is provided on gamma and neutron based MC and A measurements. This material serves as a condensed MC and A encyclopedia. By supplying an interactive CD with an NDA instrument, nuclear facilities will have greater assurance operators are properly trained in the set-up and operation of the NDA-equipment

  19. Review and Ranking of NDA Techniques to Determine Plutonium Content in Spent Fuel

    International Nuclear Information System (INIS)

    Cheatham, Jesse R.; Wagner, John C.

    2010-01-01

    A number of efforts are under way to improve nondestructive assay (NDA) techniques for spent nuclear fuel (SNF) safeguard applications. These efforts have largely focused on advancing individual NDA approaches to assay plutonium content. Although significant improvements have been made in NDA techniques, relatively little work has been done to thoroughly and systematically compare the methods. A comparative review of the relative strengths and weaknesses of current NDA techniques brings a new perspective to guide future research. To gauge the practicality and effectiveness of the various relevant NDA approaches, criteria have been developed from two broad categories: functionality and operability. The functionality category includes accuracy estimates, measurement time, plutonium verification capabilities, and assembly or fuel rod assay. Since SNF composition changes with operational history and cooling times, the viability of certain NDA approaches will also change over time. While active interrogation approaches will benefit from reduced background radiation, passive assays will lose the information contained in short-lived isotopes. Therefore, the expected assay accuracy as a function of time is considered. The operability category attempts to gauge the challenges associated with the application of different NDA techniques. This category examines the NDA deploy-ability, measurement capabilities and constraints in spent fuel pools, required on-site facilities, NDA technique synergies, and the extent to which the measurements are obtrusive to the facility. Each topic listed in the categories will be given a numerical score used to rank the different NDA approaches. While the combined numerical score of each technique is informative, the individual-topic scoring will allow for a more-tailored ranking approach. Since the needs and tools of the International Atomic Energy Agency differ from those of a recycling facility, the best assay technique may change with users

  20. Portable sandblaster cleans small areas

    Science.gov (United States)

    Severin, H. J.

    1966-01-01

    Portable sandblasting unit rapidly and effectively cleans localized areas on a metal surface. The unit incorporates a bellows enclosure, masking plate, sand container, and used sand accummulator connected to a vacuum system. The bellows is equipped with an inspection window and light for observation of the sanding operation.

  1. Portable radiation meters evaluation in high rates of air kerma

    International Nuclear Information System (INIS)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Vivolo, Vitor

    2015-01-01

    A set of portable meters of ionizing radiation high rates of air kerma (teletectors) commonly used in emergencies in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analyst is parameters for the detectors behavior were established, specifying their sensitivities and operating characteristics. Applied tests were: reading equipment variation with battery voltage, geotropism effect, energy dependence, the angular dependence and overload. Thus it was possible to determine the most common characteristic found in these equipment (quality control programs). The behavior of 17 portable meters was analyzed and in this study, 10 of them have been tested. It was performed to characterize the gamma irradiating system (radiation dosimetry field) that possesses higher activity in teletectors for testing of larger measuring range. New calibration criteria were established following international recommendations. Therefore, it was made the improvement of the quality control programme of portable meters of ionizing radiation high rates of air kerma calibration laboratory, benefiting the users of such equipment with better consistent calibration measurements. (author)

  2. NDA 2000 -- A modern, networked laboratory

    International Nuclear Information System (INIS)

    Thompson, K.A.; Ceo, R.N.

    1996-01-01

    As part of the modernization process, the Nondestructive Analysis (NDA) laboratory at Oak Ridge is undergoing changes to increase reliability, incorporate new analytical techniques, and improve quality assurance. The data system has been decentralized into a network, allowing any instrument to be controlled from any client, even remotely for trouble shooting purposes. By making the computers interchangeable, reliability increases. The software has been redesigned to function on a network, and incorporates several improvements to enhance accuracy and include quality assurance. The emphasis of this paper is directed at the actual hardware and software to integrate NDA 2000. Another paper (Reference 1) by the same authors presented at this symposium gives more details concerning new analytical and QA techniques

  3. NDA generic research programme for higher activity waste management issues - 16390

    International Nuclear Information System (INIS)

    McKinney, James; Brownridge, Melanie

    2009-01-01

    NDA has a responsibility to ensure decommissioning activities are sufficiently technically underpinned and appropriate Research and Development (Rand D) is carried out. The NDA funds research and development (R and D) indirectly via the Site Licence Companies (SLCs) or directly. The main component of directly funded R and D is the NDA Direct Research Portfolio (DRP). The DRP is split into four framework areas: - University Interactions; - Waste Processing; - Material Characterisation; - Actinide and Strategic Nuclear Materials. These four framework areas were competed through an Official Journal of European Union (OJEU) process in 2008. Although all four areas involve waste management, Waste Processing and Material Characterisation specifically deal with Higher Activity Waste (HAW) waste management issues. The Waste Processing area was awarded to three groups: (i) National Nuclear Laboratory (NNL), (ii) Consortium led by Hyder Consulting Ltd, and (iii) Consortium led by UKAEA Ltd. The Material Characterisation area was awarded to three groups: (i) NNL, (ii) Serco, and (iii) Consortium led by UKAEA Ltd. The initial work in Waste Processing and Material Characterisation was centered on establishing a forward research programme to address the generic needs of the UK civil nuclear industry and the NDA strategic drivers for waste management and land quality. This has been achieved by the four main framework contractors from the Waste Processing and Materials Characterisation areas working together with the NDA to identify the key research themes and begin the development of the NDA's HAW Management Research Programme. The process also involves active engagement with both industry and regulators via the Nuclear Waste Research Forum (NWRF). The NDA's HAW Management Research Programme includes a number of themes: - Optimisation of Interim Store Operation and Design; - Alternative Waste Encapsulants; - Waste Package Integrity; - Alternative Waste treatment methods

  4. NDA National Graduate Programme 'nucleargraduates'

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Carl

    2010-07-01

    The aim of this paper is to outline the NDA National Graduate Programme (nuclear graduates). The NDA has a remit under the Energy Act (2004) 'to maintain and develop the skills for decommissioning and nuclear clean-up'. Although current research is now being reviewed, there is significant evidence to suggest that the age profile in the Site Licence Companies is skewed towards older workers and there is likely to be a skill shortage in 3-5 years. As nuclear clean-up is a national issue; skill shortages also become a national issue in a very real sense. In addition, evidence suggests that the industry needs to be constantly challenged in order to achieve its targets for decommissioning. The NDA has a unique position under the Act. It is both a strategic overseer and direct employer. To this end the 'National Graduate Programme' is aligned to both the NDA's previous succession plans and the needs of the industry. Industry needs leadership that challenges the status quo and moves the UK nuclear industry to become best in class; Industry needs a dedicated to programme to address skills shortages and difficult to recruit areas such as, but not exclusively, estimators, schedulers, contract managers, site engineers, decommissioning technicians, safety monitors; The NDA has indicated a 'commercial and politically savvy' cohort is required to meet its own internal challenges and to ensure sustainability in its own workforce, and to be sensitive to the needs of customers and suppliers alike; Need to create a more diversified workforce in the nuclear industry and also plan for new skills evolving from research and development breakthroughs; Need to ensure that Tier 1, 2, 3 and 4 contractors invest in the leadership and skills for the future. World Class - delivery will be benchmarked against UK based multinational companies who operate in a global graduate attraction and development marketplace. The graduates targeted will be from leading

  5. Enflasyon Ortamında Mamul Fiyatlandırması

    OpenAIRE

    GÜNEŞ, Recep

    2013-01-01

    Fiyatlandırma konusu farklı bilim dallarında farklı varsayımlaradayandırılarak açıklanmaya çalışılırken, uygulama alanındamaliyet artı metodunun önemli bir yer tuttuğu yapılan saha çalışmalarındaortaya konulmuştur. Maliyet artı kar metodunun genelolarak enflasyonun olmadığı ortamlarda kolayca uygulanabilirken,maliyetlerin sürekli değiştiği enflasyon ortamında fiyatlandırmadaha da karmaşık bir görünüm arz etmektedir. Bu çalışmada,enflasyon ortamında maliyet artı kar metodunun uygulanabilirliği...

  6. Setup and organisation of a NDA-system procurement project

    International Nuclear Information System (INIS)

    Botte, John; Gielen, Paul

    2007-01-01

    Belgoprocess is momentarily in the process of purchasing its fifth NDA-system. Measurement systems are, although based on general designs, not from the shelf items but tailor-made sophisticated and highly automated devices. It is obvious that such a project cannot be carried out by solely a NDA team, but needs a multifunctional team. This team combines NDA expertise with experts in civil works, electrical and mechanical engineering, procurement, IT, safety and legal administration. From less positive experiences in the past, Belgoprocess learned a lot and has now a systematic in place. This systematic structures the project from definition of requirements to operation, a two to three year process. This paper defines the phases of a NDA project and gives for each phase some do's and don'ts. A second subject is the writing and handling of the vast but needed and required documentation. It gives a brief overview of the over thirty documents and files needed. The described, integrated and formal approach reduces the risk of failing projects, systems not meeting the expectations or denied qualification. It puts clear agreements in place, smoothening the relationship between company, supplier and authorities. (authors)

  7. Performance values for non destructive assay (NDA) techniques applied to safeguards: the 2002 evaluation by the ESARDA NDA Working Group

    International Nuclear Information System (INIS)

    Guardini, S.

    2003-01-01

    The first evaluation of NDA performance values undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques (WGNDA) was published in 1993. Almost 10 years later the Working Group decided to review those values, to report about improvements and to issue new performance values for techniques which were not applied in the early nineties, or were at that time only emerging. Non-Destructive Assay techniques have become more and more important in recent years, and they are used to a large extent in nuclear material accountancy and control both by operators and control authorities. As a consequence, the performance evaluation for NDA techniques is of particular relevance to safeguards authorities in optimising Safeguards operations and reducing costs. Performance values are important also for NMAC regulators, to define detection levels, limits for anomalies, goal quantities and to negotiate basic audit rules. This paper presents the latest evaluation of ESARDA Performance Values (EPVs) for the most common NDA techniques currently used for the assay of nuclear materials for Safeguards purposes. The main topics covered by the document are: techniques for plutonium bearing materials: PuO 2 and MOX; techniques for U-bearing materials; techniques for U and Pu in liquid form; techniques for spent fuel assay. This issue of the performance values is the result of specific international round robin exercises, field measurements and ad hoc experiments, evaluated and discussed in the ESARDA NDA Working Group. (author)

  8. Fabricating defensible reference standards for the NDA lab

    Energy Technology Data Exchange (ETDEWEB)

    Ceo, R.N.; May, P.K. [Oak Ridge Y-12 Plant, TN (United States)

    1997-11-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs.

  9. Fabricating defensible reference standards for the NDA lab

    International Nuclear Information System (INIS)

    Ceo, R.N.; May, P.K.

    1997-01-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs

  10. Kazak Mitleri ve Mitik Efsaneleri Hakkında

    OpenAIRE

    İBRAYEV, Şakir; ARIKAN, Metin

    2006-01-01

    Kazak halkının geleneksel dünya görüşü ile söz sanatının kaynağı diyebileceğimiz mitler; dünyanın yaratılışı, nelerin, nasıl, nereden meydana çıktığı, sebebi ve safhaları, etrafımızı kuşatan çevrenin sırları ve özellikleri hakkında söylenen, insanoğlunun ilkel düşüncesinin sonucu meydana gelen olağanüstü anlatmalar, belki de inanışlar, anlayışlar. En eski mitlerin arasında gökyüzü cisimleri - güneş, ay, yıldız ve gezegenler hakkında söylenilen mitleri gösterebiliriz. Bu türdeki mitlerin başlı...

  11. 30 CFR 77.1109 - Quantity and location of firefighting equipment.

    Science.gov (United States)

    2010-07-01

    ... equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment... tank. (f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection...

  12. Preparation of plant-specific NDA reference material

    International Nuclear Information System (INIS)

    Abedin-Zadeh, R.; Beetle, T.; Kuhn, E.; Terrey, D.; Turel, S.; Busca, G.; Guardini, S.

    1983-01-01

    The importance of having suitable and well characterized non-destructive assay (NDA) reference materials for the verification activities of the safeguards control authorities is stressed. The Euratom Inspectorate and the IAEA have initiated an extensive programme for the procurement and preparation of Joint Euratom/IAEA safeguards NDA reference materials with the active participation of the Ispra Establishment of the Euratom Joint Research Centre. The different type and nature of materials, condition of measurements, and plant characteristics and provisions had to be taken into account for plant-specific NDA reference materials. The preparation of each reference material was planned case by case and specific criteria such as limitations in different facilities, measurement capabilities, conditions, product availability and population variability are being ascertained. A procurement scheme was prepared describing step-by-step procedures detailing responsibilities, measurement conditions, destructive analysis schemes, desired characteristics and methods of data evaluation. This paper describes the principles and procedures carried out for the preparation of a reference MOX pin, low enriched uranium reference rods, low enriched uranium reference drums, reference MTR assemblies, and THTR reference pebbles. The scheme for each characterization technique is presented. (author)

  13. Performance Values for Non-Destructive Assay (NDA) Technique Applied to Wastes: Evaluation by the ESARDA NDA Working Group

    International Nuclear Information System (INIS)

    Rackham, Jamie; Weber, Anne-Laure; Chard, Patrick

    2012-01-01

    The first evaluation of NDA performance values was undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques and was published in 1993. Almost ten years later in 2002 the Working Group reviewed those values and reported on improvements in performance values and new measurement techniques that had emerged since the original assessment. The 2002 evaluation of NDA performance values did not include waste measurements (although these had been incorporated into the 1993 exercise), because although the same measurement techniques are generally applied, the performance is significantly different compared to the assay of conventional Safeguarded special nuclear material. It was therefore considered more appropriate to perform a separate evaluation of performance values for waste assay. Waste assay is becoming increasingly important within the Safeguards community, particularly since the implementation of the Additional Protocol, which calls for declaration of plutonium and HEU bearing waste in addition to information on existing declared material or facilities. Improvements in the measurement performance in recent years, in particular the accuracy, mean that special nuclear materials can now be accounted for in wastes with greater certainty. This paper presents an evaluation of performance values for the NDA techniques in common usage for the assay of waste containing special nuclear material. The main topics covered by the document are: 1- Techniques for plutonium bearing solid wastes 2- Techniques for uranium bearing solid wastes 3 - Techniques for assay of fissile material in spent fuel wastes. Originally it was intended to include performance values for measurements of uranium and plutonium in liquid wastes; however, as no performance data for liquid waste measurements was obtained it was decided to exclude liquid wastes from this report. This issue of the performance values for waste assay has been evaluated and discussed by the ESARDA

  14. Performance Values for Non-Destructive Assay (NDA) Technique Applied to Wastes: Evaluation by the ESARDA NDA Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Rackham, Jamie [Babcock International Group, Sellafield, Seascale, Cumbria, (United Kingdom); Weber, Anne-Laure [Institut de Radioprotection et de Surete Nucleaire Fontenay-Aux-Roses (France); Chard, Patrick [Canberra, Forss Business and Technology park, Thurso, Caithness (United Kingdom)

    2012-12-15

    The first evaluation of NDA performance values was undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques and was published in 1993. Almost ten years later in 2002 the Working Group reviewed those values and reported on improvements in performance values and new measurement techniques that had emerged since the original assessment. The 2002 evaluation of NDA performance values did not include waste measurements (although these had been incorporated into the 1993 exercise), because although the same measurement techniques are generally applied, the performance is significantly different compared to the assay of conventional Safeguarded special nuclear material. It was therefore considered more appropriate to perform a separate evaluation of performance values for waste assay. Waste assay is becoming increasingly important within the Safeguards community, particularly since the implementation of the Additional Protocol, which calls for declaration of plutonium and HEU bearing waste in addition to information on existing declared material or facilities. Improvements in the measurement performance in recent years, in particular the accuracy, mean that special nuclear materials can now be accounted for in wastes with greater certainty. This paper presents an evaluation of performance values for the NDA techniques in common usage for the assay of waste containing special nuclear material. The main topics covered by the document are: 1- Techniques for plutonium bearing solid wastes 2- Techniques for uranium bearing solid wastes 3 - Techniques for assay of fissile material in spent fuel wastes. Originally it was intended to include performance values for measurements of uranium and plutonium in liquid wastes; however, as no performance data for liquid waste measurements was obtained it was decided to exclude liquid wastes from this report. This issue of the performance values for waste assay has been evaluated and discussed by the ESARDA

  15. Portable Diode Laser Diagnostic System for Collaborative Research on Air-Breathing Combustion

    National Research Council Canada - National Science Library

    Hanson, Ronald

    2003-01-01

    This equipment grant focused on four areas: (1) portable diode laser sensors with new fiber-coupled diode lasers and the support equipment to provide higher power with extended wavelength tuning range and speed; (2...

  16. 75 FR 221 - Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire...

    Science.gov (United States)

    2010-01-05

    ... Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire Extinguishers as Installed... specification, have been supplied to the aviation industry for use in fire extinguishing equipment. * * * * * * * * * * * This Halon 1211 has subsequently been used to fill certain FFE [Fire Fighting Enterprises] portable...

  17. Equipment support for the implementation of safeguards

    International Nuclear Information System (INIS)

    Arlt, R.; Bosler, G.; Goldfarb, M.; Schanfein, M.; Whichello, J.

    2001-01-01

    Full text: The provision of effective, reliable, and user-friendly equipment needed for the implementation of safeguards is one of the main objectives of the Division of Technical Services (SOTS) in the Department of Safeguards. As an outcome of a review by an independent external consultant firm, the instrumentation sections of the SGTS were reorganized in January 2001 into two new sections, the Section for NDA Systems and Seals (TNS) and Section for Installed Systems (TIE). Each section has 'cradle-to-grave' responsibilities for development, implementation, maintenance, and decommissioning of safeguards instruments and measurement systems. Unattended assay, monitoring and surveillance instruments are the responsibility of TIE while attended nondestructive assay (NDA) instruments and seals are handled by TNS. The principal goals of both sections are to define equipment requirements based on Departmental needs, to coordinate Support Programme tasks concerning development and implementation activities, to provide system engineering of commercial components, manage laboratory and to do field testing and prove system suitability for defined safeguards applications. In addition both sections coordinate equipment and supply needs for the Department, including acquisition, preparation, servicing, installation, commissioning, troubleshooting, maintenance and repair, ensuring their availability when needed. As required, TIE and TNS provide specialized field support to the Operations Divisions. Each section is working to standardize equipment as much as possible and reduce the number of instruments performing the same function. This reduces both inspector and technician training, required parts inventories, and overall life-cycle costs. Development based on User Needs from the Operations Divisions follows a strict quality control program that includes a thorough qualification testing procedure with the last phase being field-testing under actual facility conditions. A

  18. A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

    Directory of Open Access Journals (Sweden)

    Brian C W Kot

    Full Text Available Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS may be difficult in most veterinary settings. The present study evaluated the inter-equipment variability in dolphin thyroid ultrasound measurements between a portable ultrasound unit (PUS and a FCUS; for both units, repeatability was also assessed. Thyroid ultrasound examinations were performed on 15 apparently healthy bottlenose dolphins with both PUS and FCUS under identical scanning conditions. There was a high level of agreement between the two ultrasound units in dolphin thyroid measurements (ICC = 0.859-0.976. A high intra-operator repeatability in thyroid measurements was found (PUS: ICC = 0.854-0.984, FCUS: ICC = 0.709-0.954. As a conclusion, no substantial inter-equipment variability was found between PUS and FCUS in dolphin thyroid size measurements under identical scanning conditions, supporting further application of PUS for quantitative analyses of dolphin thyroid gland in both research and clinical practices at aquarium settings.

  19. Development plan of Pu NDA system using ZnS ceramic scintillator

    International Nuclear Information System (INIS)

    Kureta, Masatoshi; Soyama, Kazuhiko; Seya, Michio; Ohzu, Akira; Haruyama, Mitsuo; Takase, Misao; Sakasai, Kaoru; Nakamura, Tatsuya; Toh, Kentaro

    2012-01-01

    Alternative techniques to neutron detection by He-3 for nuclear security and safeguards systems are necessary to be developed since He-3 shortage is serious. With support of Japanese government (the Ministry of Education, Culture, Sports, and Technology), we have started an R and D project of Pu NDA system using ZnS ceramic scintillator. Here we present development plan, production of a new type of ZnS ceramic scintillator experimentally and basic design of a PCAS alternative Pu NDA system. We are planning the demonstration tests using the alternative NDA system comparing with the current PCAS in which the He-3 counters are installed. (author)

  20. Portable Battery Charger Berbasis Sel Surya

    OpenAIRE

    Anto, Budhi; Hamdani, Edy; Abdullah, Rizki

    2014-01-01

    A type of solar battery charger is introduced in this paper. This equipment functions as a medium size rechargeable battery that is needed to move culinary merchants and coastal fishermen living in area which is not supplied by electrical networks. The equipment consists of solar module mounted onto portable mechanical construction, a 12-V 7.5-Ah lead acid battery and charge controller. Solar module charges the battery through charge controller and then the battery can be discharged to power ...

  1. Performance results from the first integrated NDA VXI safeguards system

    International Nuclear Information System (INIS)

    Bot, D.; Messner, R.

    1999-01-01

    The VIFM system is the first integrated safeguard system to be developed and deployed by the IAEA. The system is also noteworthy in that it is the most versatile of any NDA system thus far deployed. Due to the high level of functionality, the VIFM is probably the most 'tested' of all IAEA systems. This paper discusses the results obtained from detailed in field and laboratory testing of a variety of VIFM configurations ranging from simple single systems to highly integrated system implementations. A total of 4 sites have had VIFM equipment installed. Data collected from these sites have been of very high quality and consistency despite the failure of commercial hard disk drive equipment. The systematic failure of these drives have been corrected using a variety of methods and performance since those corrections have been excellent with no equipment failures. The tests carried out also included the test of a twisted pair to coaxial cable interface. This interface was required in order to allow installation even with a significant facility cabling limitation. The performance obtained from the system utilizing this device showed no degradation as compared to that of systems utilizing direct coaxial cable connections. To conclude, the VIFM system, has been reliable even after partial failure of commercial off-the-shelf components which required the systems to operate on full fail-safe backup. These tests have thus shown both the reliable operation of the VIFM in normal operating conditions as well as the most adverse

  2. 29 CFR 1910.306 - Specific purpose equipment and installations.

    Science.gov (United States)

    2010-07-01

    ...) Cranes and hoists. This paragraph applies to the installation of electric equipment and wiring used in..., and similar events. This paragraph covers the installation of portable wiring and equipment, including... 29 Labor 5 2010-07-01 2010-07-01 false Specific purpose equipment and installations. 1910.306...

  3. Portable Chemical Sterilizer for Microbial Decontamination of Surgical Instruments, Fruits and Vegetables, and Field Feeding Equipment

    National Research Council Canada - National Science Library

    Doona, C. J; Feeherry, F. E; Kustin, K; Curtin, M. A; Baer, D. G

    2006-01-01

    The Portable Chemical Sterilizer (PCS) is a revolutionary biomedical sterilization technology that provides the capability for portable, power-free, point-of-use sterilization to meet the Army's Far-Forward Surgical Teams (FSTs...

  4. Creating NDA working standards through high-fidelity spent fuel modeling

    International Nuclear Information System (INIS)

    Skutnik, Steven E.; Gauld, Ian C.; Romano, Catherine E.; Trellue, Holly

    2012-01-01

    The Next Generation Safeguards Initiative (NGSI) is developing advanced non-destructive assay (NDA) techniques for spent nuclear fuel assemblies to advance the state-of-the-art in safeguards measurements. These measurements aim beyond the capabilities of existing methods to include the evaluation of plutonium and fissile material inventory, independent of operator declarations. Testing and evaluation of advanced NDA performance will require reference assemblies with well-characterized compositions to serve as working standards against which the NDA methods can be benchmarked and for uncertainty quantification. To support the development of standards for the NGSI spent fuel NDA project, high-fidelity modeling of irradiated fuel assemblies is being performed to characterize fuel compositions and radiation emission data. The assembly depletion simulations apply detailed operating history information and core simulation data as it is available to perform high fidelity axial and pin-by-pin fuel characterization for more than 1600 nuclides. The resulting pin-by-pin isotopic inventories are used to optimize the NDA measurements and provide information necessary to unfold and interpret the measurement data, e.g., passive gamma emitters, neutron emitters, neutron absorbers, and fissile content. A key requirement of this study is the analysis of uncertainties associated with the calculated compositions and signatures for the standard assemblies; uncertainties introduced by the calculation methods, nuclear data, and operating information. An integral part of this assessment involves the application of experimental data from destructive radiochemical assay to assess the uncertainty and bias in computed inventories, the impact of parameters such as assembly burnup gradients and burnable poisons, and the influence of neighboring assemblies on periphery rods. This paper will present the results of high fidelity assembly depletion modeling and uncertainty analysis from independent

  5. NDA [nondestructive assay] for a facility at SRP

    International Nuclear Information System (INIS)

    Studley, R.V.

    1987-01-01

    A near-real-time accountability system with associated high accuracy assay measurements has recently been placed in service at a Savannah River Plant (SRP) facility. A computer cluster provides facility wide communication between personnel and the accountability, process control, and laboratory data systems. The cluster is also connected to communicate with process, accountability, and laboratory instrumentation and process controls plus an item tracking bar code printer/reader system. Eight high performance microprocessor-based nondestructive assay (NDA) systems which were developed at the Los Alamos National Laboratory (LANL) for this process are also connected to this cluster. With standards developed for them, these instruments are achieving the highest currently known NDA measurement accuracies

  6. Evalution of NDA techniques and instruments for assay of nuclear waste at a waste terminal storage facility

    International Nuclear Information System (INIS)

    Blakeman, E.D.; Allen, E.J.; Jenkins, J.D.

    1978-05-01

    The use of Nondestructive Assay (NDA) instrumentation at a nuclear waste terminal storage facility for purposes of Special Nuclear Material (SNM) accountability is evaluated. Background information is given concerning general NDA techniques and the relative advantages and disadvantages of active and passive NDA methods are discussed. The projected characteristics and amounts of nuclear wastes that will be delivered to a waste terminal storage facility are presented. Wastes are divided into four categories: High Level Waste, Cladding Waste, Intermediate Level Waste, and Low Level Waste. Applications of NDA methods to the assay of these waste types is discussed. Several existing active and passive NDA instruments are described and, where applicable, results of assays performed on wastes in large containers (e.g., 55-gal drums) are given. It is concluded that it will be difficult to routinely achieve accuracies better than approximately 10--30% with ''simple'' NDA devices or 5--20% with more sohpisticated NDA instruments for compacted wastes. It is recommended that NDA instruments not be used for safeguards accountability at a waste storage facility. It is concluded that item accountability methods be implemented. These conclusions and recommendations are detailed in a concurrent report entitled ''Recommendations on the Safeguards Requirements Related to the Accountability of Special Nuclear Material at Waste Terminal Storage Facilities'' by J.D. Jenkins, E.J. Allen and E.D. Blakeman

  7. Tiyatro, karikatür ve film provokasyonları bağlamında Fransız basınında İslam ve Hz. Muhammed imajı

    OpenAIRE

    METİN, İsmail

    2016-01-01

    Oryantalizm ve oryantalistler, tarih boyunca İslamı kendi zihin dünyasına göre anlamış ve bu yönde çalışmalar yapmıştır. Yapılan bu çalışmalar ilmi eserler, ansiklopediler, kitaplar, makaleler başta olmak üzere, yazılı ve görsel basında da yer almıştır. Bu makale, oryantalizmin önemli merkezlerinden olan Fransada, özellikle yazılı basında, başta İslam, Kuran-ı Kerim, Hz. Muhammed olmak üzere dini değerlerin medya tarafından algılanış biçimini, karikatür ve film provokasyonları bağlamında tari...

  8. Tackling field-portable Raman spectroscopy of real world samples

    Science.gov (United States)

    Shand, Neil C.

    2008-10-01

    A major challenge confronting first responders, customs authorities and other security-related organisations is the accurate, rapid, and safe identification of potentially hazardous chemicals outside a laboratory environment. Currently, a range of hand portable Raman equipment is commercially available that is low cost and increasingly more sophisticated. These systems are generally based on the 785nm Stokes shifted Raman technique with many using dispersive grating spectrometers. This technique offers a broad range of capabilities including the ability to analyse illicit drugs, explosives, chemical weapons and pre-cursors but still has some fundamental constraints. 'Real world' samples, such as those found at a crime scene, will often not be presented in the most accessible manner. Simple issues such as glass fluorescence can make an otherwise tractable sample impossible to analyse in-situ. A new generation of portable Raman equipment is currently being developed to address these issues. Consideration is given to the use of longer wavelength for fluorescence reduction. Alternative optical designs are being tested to compensate for the signal reduction incurred by moving to longer wavelengths. Furthermore, the use of anti-Stokes spectroscopy is being considered as well as investigating the robustness and portability of traditional Fourier Transform interferometer designs along with future advances in detector technology and ultra small spectrometers.

  9. Neutron method for NDA in the Sapphire Project

    International Nuclear Information System (INIS)

    Lewis, K.D.

    1995-01-01

    The implementation of Project Sapphire, the top-secret mission to the Republic of Kazakhstan to recover weapons-grade nuclear materials, consisted of four major elements: (1) repacking of fissile material from Kazakh containers into suitable U.S. containers; (2) nondestructive analyses (NDA) to quantify the 235 U content of each container for nuclear criticality safety and compliance purposes; (3) packaging of the fissile material containers into 6M/2R drums, which are internationally approved for shipping fissile material; and (4) shipping or transport of the recovered fissile material to the United States. This paper discusses the development and application of a passive neutron counting technique used in the NDA phase of the Sapphire operations to analyze uranium/beryllium (U/Be) alloys and compounds for 235 U content

  10. Review of portable applications of fuel cell technology 2008; Teknikbevakning av portabla tillaempningar foer braenslecellstekniken 2008

    Energy Technology Data Exchange (ETDEWEB)

    Fontes, Eva; Lundblad, Anders; Wennstam, Emelie

    2009-03-15

    The definition of portable fuel cells, or micro fuel cells as they are often called, is usually that its nominal power is below 250 W. There are, however, several widely separated applications and technical challenges in the span up to 250 W. Portable fuel cells from 1-10 W have potential applications in hand held electronics, wireless sensors, wireless networks and less power demanding equipment for outdoor life such as bicycle lamps, head lamps etc. The technical challenges involved here are mainly about cost, miniaturizing, dealing with heat rejection/cooling, stability/life and the fuel cell infrastructure - how shall the user 'fill' his/her fuel cell? Medium-sized, portable fuel cells between 10-50 W have potential applications in portable military equipment, larger portable electronics such as DVD players, camcorders and laptops (both for direct power and for charging of integrated batteries), to operate rescue equipment and as reserve power, and to replace some stationary power (APU). Also in this area challenges lie in cost, miniaturizing and heat rejection. Larger portable fuel cells of 50-250 W can for example be used in military equipment for charging of batteries, in rescue equipment and medical treatments, in boats and mobile homes, in small electric vehicles (manned or unmanned) and for remote power. In this type of replacement products the cost aspect is important, e g for material and system components. In this technique survey report we have analysed in total 31 pure micro fuel cell companies. In addition, we have also studied 14 larger electronic companies active in the fuel cell development. The three main technologies for portable fuel cell systems are Proton Exchange Membrane Fuel Cells (PEMFC), Direct Methanol Fuel Cells (DMFC) and Solid Oxide Fuel Cells (SOFC), Micro fuel cells that have been sold and have been available on the market up till today have been of the PEMFC and DMFC type and have mainly been used, to a limited extent

  11. Development of simple DSA equipment and experience of its using

    International Nuclear Information System (INIS)

    Yoshino, Fumiki; Matsuo, Michimasa.

    1984-01-01

    We manufactured a cheap and portable simple DSA equipment, consisting of an ordinary X-ray system and a microcomputer which is the hardware exclusively used for real-time processing. As the result of the basic clinical examination by simple DSA equipment, we found it effective on the follow-up study of diseases such as the arteriosclerosis obliterans. We performed the intra-arterial DSA with a catheter which was small in the inside diameter, to reduce its aggression, and at the same time we are trying its application to the functional image. In the future, it will show us the possibility of the routine screening examination at an out-patients' department. Compared with DSA equipment sold in the market, our simple DSA equipment is good enough to make diagnostic images in spite of the limited capacity of TV system. Moreover, our DSA equipment is cheap and portable, and is very effective for the follow-up study of diseases such as the arteriosclerosis obliterans. So we can say that simple DSA equipment is of excellent clinical value. (author)

  12. Automatic identification of NDA measured items: Use of E-tags

    International Nuclear Information System (INIS)

    Chitumbo, K.; Olsen, R.; Hatcher, C.R.; Kadner, S.P.

    1995-01-01

    This paper describes how electronic identification devices or E-tags could reduce the time spent by LAEA inspectors making nondestructive assay (NDA) measurements. As one example, the use of E-tags with a high-level neutron coincidence counter (HLNC) is discussed in detail. Sections of the paper include inspection procedures, system description, software, and future plans. Mounting of E-tabs, modifications to the HLNC, and the use of tamper indicating devices are also discussed. The technology appears to have wide application to different types of nuclear facilities and inspections and could significantly change NDA inspection procedures

  13. Efficient solutions to the NDA-NCA low-order eigenvalue problem

    International Nuclear Information System (INIS)

    Willert, J. A.; Kelley, C. T.

    2013-01-01

    Recent algorithmic advances combine moment-based acceleration and Jacobian-Free Newton-Krylov (JFNK) methods to accelerate the computation of the dominant eigenvalue in a k-eigenvalue calculation. In particular, NDA-NCA [1], builds a sequence of low-order (LO) diffusion-based eigenvalue problems in which the solution converges to the true eigenvalue solution. Within NDA-NCA, the solution to the LO k-eigenvalue problem is computed by solving a system of nonlinear equation using some variant of Newton's method. We show that we can speed up the solution to the LO problem dramatically by abandoning the JFNK method and exploiting the structure of the Jacobian matrix. (authors)

  14. Laboratory services series: an electrical outlet and corded equipment inspection program

    International Nuclear Information System (INIS)

    Davis, E.A.

    1976-04-01

    A research and development laboratory has thousands of electrical outlets providing power to laboratories, offices, shops, and service areas. These outlets provide power for a wide variety of portable equipment and tools that are equipped with cord and plug. Electric safety requires a periodic check of outlet grounding capability and continuing inspection and repair of corded equipment. Personnel, equipment, reports, procedures, and schedule requirements are reported

  15. Portable energy: autonomy and integration in the human environment; Energie portable: autonomie et integration dans l'environnement humain

    Energy Technology Data Exchange (ETDEWEB)

    Multon, F; Delamarche, P [Rennes-2 Universite, Lab. de Physiologie et de Biomecanique de l& #x27; Exercice Mulsculaire, UMR. APS, 35 (France); Lucchese, P [CEA Fontenay-aux-Roses, Dir. de la Recherche Technologique, Hydrogene et Pile a Combustible, 92 (France); and others

    2002-07-01

    This colloquium was motivated by the possibility to recover in our environment the energy produced by our movements, but also the heat emitted and the radiations received by the human body in order to supply the energy needs of portable electronic devices (telephones, micro-computers, watches, prostheses etc..). It tries to answer the different problems raised by the implementation of portable energy sources: the energy resources in the human environment, the physical and technological processes of energy production and storage, the electronic energy conversion and remote transmission means, the intelligent energy management, and the existing and potential applications of these processes. This document brings together 16 communications presented by searchers from various domains (biology, medicine, electrochemistry, computer science, mechanics, thermodynamics, electronics etc..) on the following topics: energy in the human body, possibilities of miniaturization of fuel cells, thermo-mechanical micro-generators, thermoelectric generation, solar cells and autonomy, micro-chargeable batteries, double-layer super-capacitors (principles and electrical behaviour), renewable energies in watches, electro-mechanical devices for the exploitation of human movements energy, trans-dermal power supply, new mechanical-aided systems for blood circulation, problems and their solutions related to portable telephones, low voltage and high efficiency power electronic systems for portable applications, remote energy transmission, intelligent energy management (equipments and softwares), electromagnetic environments and health. (J.S.)

  16. Evaluation of portable near-infrared spectroscopy for organic milk authentication

    NARCIS (Netherlands)

    Liu, Ningjing; Parra, Hector Aya; Pustjens, Annemieke; Hettinga, Kasper; Mongondry, Philippe; Ruth, van Saskia M.

    2018-01-01

    Organic products are vulnerable to fraud due to their premium price. Analytical methodology helps to manage the risk of fraud and due to the miniaturization of equipment, tests may nowadays even be rapidly applied on-site. The current study aimed to evaluate portable near infrared spectroscopy

  17. Portable recording in the assessment of obstructive sleep apnea. ASDA standards of practice.

    Science.gov (United States)

    Ferber, R; Millman, R; Coppola, M; Fleetham, J; Murray, C F; Iber, C; McCall, V; Nino-Murcia, G; Pressman, M; Sanders, M

    1994-06-01

    The objective assessment of patients with a presumptive diagnosis of obstructive sleep apnea (OSA) has primarily used attended polysomnographic study. Recent technologic advances and issues of availability, convenience and cost have led to a rapid increase in the use of portable recording devices. However, limited scientific information has been published regarding the evaluation of the efficacy, accuracy, validity, utility, cost effectiveness and limitations of this portable equipment. Attaining a clear assessment of the role of portable devices is complicated by the multiplicity of recording systems and the variability of clinical settings in which they have been analyzed. This paper reviews the current knowledge base regarding portable recording in the assessment of OSA, including technical considerations, validation studies, potential advantages and disadvantages, issues of safety, current clinical usage and areas most in need of further study.

  18. Portable Weather Applications for General Aviation Pilots.

    Science.gov (United States)

    Ahlstrom, Ulf; Ohneiser, Oliver; Caddigan, Eamon

    2016-09-01

    The objective of this study was to examine the potential benefits and impact on pilot behavior from the use of portable weather applications. Seventy general aviation (GA) pilots participated in the study. Each pilot was randomly assigned to an experimental or a control group and flew a simulated single-engine GA aircraft, initially under visual meteorological conditions (VMC). The experimental group was equipped with a portable weather application during flight. We recorded measures for weather situation awareness (WSA), decision making, cognitive engagement, and distance from the aircraft to hazardous weather. We found positive effects from the use of the portable weather application, with an increased WSA for the experimental group, which resulted in credibly larger route deviations and credibly greater distances to hazardous weather (≥30 dBZ cells) compared with the control group. Nevertheless, both groups flew less than 20 statute miles from hazardous weather cells, thus failing to follow current weather-avoidance guidelines. We also found a credibly higher cognitive engagement (prefrontal oxygenation levels) for the experimental group, possibly reflecting increased flight planning and decision making on the part of the pilots. Overall, the study outcome supports our hypothesis that portable weather displays can be used without degrading pilot performance on safety-related flight tasks, actions, and decisions as measured within the constraints of the present study. However, it also shows that an increased WSA does not automatically translate to enhanced flight behavior. The study outcome contributes to our knowledge of the effect of portable weather applications on pilot behavior and decision making. © 2016, Human Factors and Ergonomics Society.

  19. High-voltage power supply of ND6 portable dose rate meter

    International Nuclear Information System (INIS)

    Wang Shaling

    2001-01-01

    Portable dose rate meter needs to be equipped with a set of high-voltage power supply which is supplied by batteries and has characteristic of high quality, low energy expense and small size. The author introduces application conditions and performance guide line

  20. Portable Battery Charger Berbasis Sel Surya

    Directory of Open Access Journals (Sweden)

    Budhi Anto

    2014-04-01

    Full Text Available A type of solar battery charger is introduced in this paper. This equipment functions as a medium size rechargeable battery that is needed to move culinary merchants and coastal fishermen living in area which is not supplied by electrical networks. The equipment consists of solar module mounted onto portable mechanical construction, a 12-V 7.5-Ah lead acid battery and charge controller. Solar module charges the battery through charge controller and then the battery can be discharged to power on electric lamps for lightening culinary wagon or fisherman’s boat at night. Charge controller charges the battery with float charging which is implemented by maintaining 13.5 Volt between battery terminals and limiting the charging current to 1.5 Amperes. Charge controller circuit is based on adjustable linear voltage regulator LM338. The battery is of sealed lead acid type. This type of battery is maintenance free and more hygiene than other types of lead acid battery. The field experiment of charging the baterry of 50% residual capacity from 8 am to 4 pm under sunny weather shows that the solar module has charged the battery to its full capacity under battery safe charging conditions.Keywords: portable solar battery charger, float charging, LM338

  1. A study on the scattered dose in portable chest radiography

    International Nuclear Information System (INIS)

    Ahn, Bong Seon; Lee, Hwan Hyung

    2000-01-01

    The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. The average of distance of adjacent patients was 219.1 cm at the ward. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it dose not have influence on the adjacent patient. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment

  2. 46 CFR 167.45-30 - Use of approved fire-fighting equipment.

    Science.gov (United States)

    2010-10-01

    ... PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-30 Use of approved fire-fighting equipment. Portable fire extinguishers or fire-extinguishing systems which conform... 46 Shipping 7 2010-10-01 2010-10-01 false Use of approved fire-fighting equipment. 167.45-30...

  3. NDA PDP Program PuO2 increased particle size specification and design

    International Nuclear Information System (INIS)

    Marshall, R.S.; Taggart, D.P.; Becker, G.K.; Woon, W.Y.

    1996-01-01

    Provisions in the National TRU Program Quality Assurance Program Plan require an assessment of performance for nondestructive waste assay (NDA) systems employed in the program. This requirement is in part fulfilled through the use of Performance Demonstration programs. In order to optimize the quality and quantity of information acquired during a given Performance Demonstration Program cycle, the assessment employed is to be carefully specified and designed. The assessment must yield measurement system performance data meaningful with respect to NDA system capability to accommodate attributes of interest known to occur in actual waste forms. The design and specification of the increased particle size PuO 2 PDP working reference materials (WRMs) is directed at providing a straightforward mechanism to assess waste NDA system capability to account for biases introduced by large PuO 2 particles. The increased particle size PuO 2 PDP WRM design addresses actual waste form attributes associated with PuO 2 particle size and distributions thereof, the issue of a known and stable WRM configuration and equally important appropriate certification and tractability considerations

  4. ORO appraisal strategy involving use of NDA instrumentation

    International Nuclear Information System (INIS)

    Lux, C.R.

    1977-12-01

    ORO has used the following nondestructive assay (NDA) systems for verifying uranium inventories at contractor-operated installations: gamma spectroscopy, thickness-corrected gamma spectroscopy, passive neutron measurement, and random driver measurement. A brief description of each system is given and results of in-field measurements performed on contractors' inventories utilizing each system are discussed

  5. A neutron method for NDA analysis in the SAPPHIRE Project

    International Nuclear Information System (INIS)

    Lewis, K.D.

    1995-01-01

    The implementation of Project SAPPHIRE, the top secret mission to the Republic of Kazakhstan to recover weapons grade nuclear materials, consisted of four major elements: (1) the re-packing of fissile material from Kazakh containers into suitable US containers; (2) nondestructive analyses (NDA) to quantify the U-235 content of each container for Nuclear Criticality Safety and compliance purposes; (3) the packaging of the fissile material containers into 6M/2R drums, which are internationally approved for shipping fissile material; and (4) the shipping or transport of the recovered fissile material to the United States. This paper discusses the development and application of a passive neutron counting technique used in the NDA phase of SAPPHIRE operations to analyze uranium/beryllium (U/Be) alloys and compounds for U-235 content

  6. Development of a portable sodium fluorescence aerosol generator model

    CERN Document Server

    LiuQun; Gao Xiao Mei; Jia Ming; Guo Chuang Cheng; Wu Tao; Liu Zhao Feng; Qiu Dan Gui

    2002-01-01

    A portable sodium fluorescence aerosol generator has been developed. It is a key equipment for in-situ testing of HEPA filters using sodium fluorescence method. The structure and technical specifications of the model generator are presented, along with its performance testing methods. The performance comparison result of the model with two French-made generators is also presented. The self-made generator has performances as follows: the average mass generating rate is 32.9 mg/h, mass median diameter of the particles 0.22 mu m and geometric standard deviation 1.58. The filtration efficiency up to 99.99% can be achieved flow-rate of ventilation system is less than 150000 m sup 3 /h. The portable model weight 25 kg, which is convenient for in situ testing

  7. Method and apparatus of a portable imaging-based measurement with self calibration

    Science.gov (United States)

    Chang, Tzyy-Shuh [Ann Arbor, MI; Huang, Hsun-Hau [Ann Arbor, MI

    2012-07-31

    A portable imaging-based measurement device is developed to perform 2D projection based measurements on an object that is difficult or dangerous to access. This device is equipped with self calibration capability and built-in operating procedures to ensure proper imaging based measurement.

  8. SMOPY, a new NDA tool for safeguards of LEU and MOX spent fuel

    International Nuclear Information System (INIS)

    Lebrun, A.; Merelli, M.; Szabo, J.-L.; Huver, M.; Arenas-Carrasco, J.

    2001-01-01

    Upon IAEA request, the French support program to IAEA Safeguards has developed a new device for control of the irradiated LEU and MOX fuels. The Safeguards Mox Python (SMOPY) is the achievement of a 4 years R and D program supported by CEA and COGEMA in partnership with Eurisys Mesures. The SMOPY system is based on the combination of 2 NDA techniques (passive neutron and room temperature gamma spectrometry) and on line interpretation tools (automatic gamma spectrum interpretation, depletion code EVO). Through the measurement managing software, all this contributes to the fully automatic measurement, interpretation and characterization of any kind of spent fuel. The device is transportable (50 kg, 60 cm) and is composed of four parts: 1. the measurement head with one high efficiency fission chamber and a micro room temperature gamma spectrometric probe; 2. the carrier which carries the measurement head. The carrier bottom fits the racks for accurate positioning and its top fits operator's fuel moving tool; 3. the portable electronic cabinet which includes both neutron and gamma electronic cards; 4. the portable PC which gets inspectors data, controls the measurement, get measured values, interprets them and immediately provides the inspector with worthwhile info for appropriate on the field decisions. Main features of SMOPY are: Discrimination of MOX versus LEU irradiated fuels in any case (conservative case is one cycle MOX versus three cycles LEU after short cooling time); Full characterization of irradiated LEU (burnup, cooling time, Pu amounts ...); Partial Defect Test on LEU fuels. A first version of SMOPY has been tested in industrial condition during summer 2000. This tests shown a need of shielding improvement around the gamma detector. A new version has been build a will be qualified during a new field test and then the system will be ready for routine operation in IAEA and commercial delivery. After giving details about the system itself, this paper

  9. Portable Fuel Cell Battery Charger with Integrated Hydrogen Generator

    Energy Technology Data Exchange (ETDEWEB)

    Bossel, Ulf G. [CH-5452 Oberrohrdorf (Switzerland)

    1999-10-01

    A fully self-sufficient portable fuel cell battery charger has been designed, built, operated and is now prepared for commercialisation. The lightweight device is equipped with 24 circular polymer electrolyte cells of an innovative design. Each cell is a complete unit and can be tested prior to stacking. Hydrogen is admitted to the anode chamber from the centre of the cell. Air can reach the cathode by diffusion through a porous metal foam layer placed between cathode and separator plate. Soft seals surround the centre hole of the cells to separate hydrogen from air. Water vapour generated by the electrochemical conversion is released into the atmosphere via the porous metal foam on the cathode. All hydrogen fed to the dead-ended anode chamber is converted to electric power. The device is equipped with a chemical hydrogen generator. The fuel gas is formed by adding small amounts of water to a particular chemical compound which is contained in disposable cartridges. With one such cartridge enough hydrogen can be generated to operate CD-players, radios, recorders or portable computers for some hours, depending on the current drawn by the electronic device. The handy portable battery charger delivers about 10 W at 12 V DC. It is designed to be used in remote areas as autonomous power source for charging batteries used in radios, CD players, cellular telephones, radio transmitters, flash lights or model air planes. The power can also be used directly to provide light, sound or motion. Patents have been filed and partners are sought for commercialisation. (author) 4 figs.

  10. Portable system for periodical verification of area monitors for neutrons

    International Nuclear Information System (INIS)

    Souza, Luciane de R.; Leite, Sandro Passos; Lopes, Ricardo Tadeu; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da; Pereira, Walsan W.

    2009-01-01

    The Neutrons Laboratory develops a project viewing the construction of a portable test system for verification of functioning conditions of neutron area monitors. This device will allow to the users the verification of the calibration maintenance of his instruments at the use installations, avoiding the use of an inadequate equipment related to his answer to the neutron beam response

  11. Türkiye Türkçesi Ağızlarında Lambdasizm Sigmatizm Meselesinin İzleri

    OpenAIRE

    YILDIZ, Hüseyin

    2015-01-01

    Lambdasizm / sigmasizm konusu gerek Türk lehçeleri arasında, gerekse Türkçeyle akraba olan diğer diller arasında tanıklanan örneklerden ortaya çıkmış problemlerdir. İçinde /l/ ünsüzü bulunan bazı kelimelerin bir başka dilde ya da lehçede /ş/’li olarak görülmesi, probleme sebep olan soruyu sordurmuştur: Hangisi daha arkaiktir? İlk olarak W. Schoot’un ortaya koyduğu bu problem hakkında Radloff, Gombocz, Németh, Benzing, Clauson, Meyer, Róna-Tas, Nauta, Scherner, Adamović, Ramstedt, Poppe, Räsän...

  12. NDA Position on the UK Management of Waste Graphite (December 2013)

    International Nuclear Information System (INIS)

    Norris, S.

    2016-01-01

    The purpose of this paper is to summarise a number of pieces of work that have been undertaken by the Nuclear Decommissioning Authority (NDA) to better understand the challenges of managing radioactive graphite wastes, these have led to an updated strategic position on graphite waste management. The updated strategic position takes into consideration Government’s response to Recommendation 8 from the Committee on Radioactive Waste Management’s (CoRWM), and provides the current NDA strategic position alongside circumstances where this should be reviewed. Two studies that provided input to this position are: 1. Operational Graphite Management Strategy: Credible and Preferred Options (Gate A & B); 2. The Long-term Management of Reactor Core Graphite Waste: Credible Options (Gate A). The paper highlights the key findings from the following work that has been undertaken to better inform this position: • A review by the NDA Radioactive Waste Management Directorate (RWMD)1 of the current baseline for managing radioactive graphite in England and Wales of geological disposal. The review identified some areas for optimisation and provided clarification on some aspects of the baseline e.g. the assumed ‘footprint’ of graphite wastes for a future Geological Disposal Facility (GDF). • Investigations into suitability of near-surface disposal options for graphite wastes. This included a review of the Low Level Waste Repository (LLWR) Ltd's new Environmental Safety Case (ESC) to assess the potential for graphite disposal and a feasibility study into a near-surface disposal facility for Higher Activity Waste (HAW) graphite at the Hunterston A site. • Continued monitoring of potential future treatment options. • Detailed characterisation work under the NDA’s Direct Research Portfolio using computer modelling and sample analysis to better understand any limitations of the current inventory data for graphite wastes. • Graphite behaviour work under the NDA

  13. Kültür Koşullarında Levrek (Dicentrarchus labrax L., 1758 Larvalarında Ağız Bölgesinin Osteolojik Gelişimi.

    Directory of Open Access Journals (Sweden)

    Deniz Çoban

    2015-12-01

    Full Text Available Levrek larvalarında 0-42. günler arasında yoğun yetiştiricilik koşulları altında ağız boşluğunda çeneye ait elementlerin kıkırdak ve kemik gelişimleri incelenmiştir. Örnekler çalışma boyunca üç günde bir olacak şekilde elde edilmiş ve çalışma canlı yeminkesilmesi ile sonlanmıştır. Elde edilen örnekler formalinde sabitlendikten sonra alcian mavisi ve alizarin kırmızısı ile boyandı. Yumurtadan çıkan larvada ağza ait bir osteolojik oluşum tespit edilmemiştir. İlk oluşan element 3,8 mm total boyda (TB Meckel’s kıkırdağıdır. Bu oluşumu 4,6 mm TB’da trabecular bar, palato-quadrate ve hyosymplectic takip eder. 5,4 mm TB’da basibranchial, hyoid bar, maksillary ve branchial sepet oral boşluğun altında meydana gelmiştir. 7,9 mm TB’da dişe ait yapıların ilk işareti olan premaksillary oluşumu gözlenmiştir. 11,4 mm TB’da premaksillary ve dentary kıkırdak yapıda olup henüz kemikleşme başlamamış olup her ikisinde de bir sıra diş tespit edilmiştir. 15,8 mm TB’da premaksillary ve dentarynin uç bölgelerinde kemikleşme başlamıştır. Bu çalışmadan elde edilen sonuçlar diğer teleostlar ile karşılaştırılmış ve benzer bulgulara rastlanmıştır

  14. Portable computers - portable operating systems

    International Nuclear Information System (INIS)

    Wiegandt, D.

    1985-01-01

    Hardware development has made rapid progress over the past decade. Computers used to have attributes like ''general purpose'' or ''universal'', nowadays they are labelled ''personal'' and ''portable''. Recently, a major manufacturing company started marketing a portable version of their personal computer. But even for these small computers the old truth still holds that the biggest disadvantage of a computer is that it must be programmed, hardware by itself does not make a computer. (orig.)

  15. Strategic plan for the development of IAEA safeguards equipment

    International Nuclear Information System (INIS)

    Khlebnikov, N.

    2001-01-01

    Full text: The need for a top-down Safeguards Strategy to focus departmental objectives was recognized by the Programme Performance Appraisal System (PPAS) performed on the Equipment Development Project in 1999. The Department of Safeguards prepared at the end of 2000 a 5-year Strategic Plan to identify the changes and improvements expected to take place over the 2001-2005 period. Those Strategic Objectives were supposed to be used to properly plan IAEA Safeguards activities and define appropriate and coherent R and D programmes. The present paper describes the strategic directions that the IAEA will follow in the area of equipment development in order to meet the Safeguards Department long-term objectives for 2001-2005. The paper, which is derived from the IAEA Strategic Equipment Development Plan, prepared by the Division of Technical Support, includes two parts: general principles and policies applicable to all equipment development tasks; specific strategic guidance. The paper will not describe the detailed plans which are prepared based on the strategic plan on a biannual basis. Equipment development activities have been divided in five major projects (NDA, Seals, Surveillance, Unattended Monitoring and Remote Monitoring). Strategic directions for each of these projects will be described in the paper. Separate sections will deal with equipment development strategic guidance in the area of additional protocol inspections, JNFL projects, illicit trafficking and Trilateral Initiative. (author)

  16. A preliminary evaluation of certain NDA techniques for RH-TRU characterization

    Energy Technology Data Exchange (ETDEWEB)

    Hartwell, J.K.; Yoon, W.Y.; Peterson, H.K. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    This report presents the results of modeling efforts to evaluate selected NDA assay methods for RH-TRU waste characterization. The target waste stream was Content Code 104/107 113-liter waste drums that comprise the majority of the INEL`s RH-TRU waste inventory. Two NDA techniques are treated in detail. One primary NDA technique examined is gamma-ray spectrometry to determine the drum fission and activation product content, and fuel sample inventory calculations using the ORIGEN code to predict the total drum inventory. A heavily shielded and strongly collimated HPGe spectrometer system was designed using MCNP modeling. Detection limits and expected precision of this approach were estimated by a combination of Monte Carlo modeling and synthetic gamma-ray spectrum generation. This technique may allow the radionuclide content of these wastes to be determined with relative standard deviations of 20 to 50% depending on the drum matrix and radionuclide. The INEL Passive/Active Neutron (PAN) assay system is the second primary technique considered. A shielded overpack for the 113-liter CC104/107 RH-TRU drums was designed to shield the PAN detectors from excessive gamma radiation. MCNP modeling suggests PAN detection limits of about 0.06 g {sup 235}U and 0.04 g {sup 239}Pu during active assays. 12 refs., 2 figs., 6 tabs.

  17. Feasibility study of a portable smelter for scrap metals

    International Nuclear Information System (INIS)

    Cavendish, J.H.

    1976-06-01

    The use of a portable smelter to process uranium-contaminated scrap metals was studied. Objectives were to convert scrap metal located at many diverse sites into a form which would be suitable for unlicensed sale and reduce the problems associated with storing the scrap. The Foundry Design Company study indicated the portable smelter concept was feasible from an equipment and transportation standpoint. Capital costs for a 5-ton/hour (steel) nominal capacity unit were estimated to be $2,349,000. Technical evaluation indicates that all the common metals considered, i.e., iron, nickel, copper, and aluminum, are amenable to uranium decontamination by smelting except aluminum. An economic evaluation of the processing of the 30,000 tons of steel scrap to be generated by the Cascade Improvement Program by a portable smelter was made based upon information supplied by Foundry Design Company, plus the assumption that the product metal could be sold for $120.00 per ton. This evaluation indicated a net return of $2,424,000 to the government could be realized. The Health and Safety study indicated no major problems of this nature would be encountered in operating a portable smelter. The legal review indicated the proposed operation fell within the authority of existing regulations. Consideration of possible conflicts with regard to competition with the private sector was suggested

  18. Survey of DOE NDA practices for CH-Tru waste certification--illustrated with a greater than 10,000 drum NDA data base

    International Nuclear Information System (INIS)

    Schultz, F.J.; Caldwell, J.T.; Smith, J.R.

    1988-01-01

    We have compiled a greater than 10,000 CH-TRU waste drum data base from seven DOE sites which have utilized such multiple NDA measurements within the past few years. Most of these nondestructive assay (NDA) technique assay result comparisons have been performed on well-characterized, segregated waste categories such as cemented sludges, combustibles, metals, graphite residues, glasses, etc., with well-known plutonium isotopic compositions. Waste segregation and categorization practices vary from one DOE site to another. Perhaps the most systematic approach has been in use for several years at the Rocky Flats Plant (RFP), operated by Rockwell International, and located near Golden, Colorado. Most of the drum assays in our data base result from assays of RFP wastes, with comparisons available between the original RFP assays and PAN assays performed independently at the Idaho National Engineering Laboratory (INEL) Solid Waste Examination Pilot Plant (SWEPP) facility. Most of the RFP assays were performed with hyperpure germanium (HPGe)-based SGS assay units. However, at least one very important waste category, processed first-stage sludges, is assayed at RFP using a sludge batch-sampling procedure, prior to filling of the waste drums. 5 refs., 5 figs

  19. Çeşitli Türk musikisi makamlarında ezan

    OpenAIRE

    KOPAR, Saadettin Volkan

    2010-01-01

    Bu çalışmada, geçmişten günümüze kadar okuna gelmiş geleneksel ezan makamlarının dışında bu güne kadar okunmamış veya kayıt altına alınmamış yedi farklı makamda ezan örnekleri sunulmuştur. Bu ezanlar, stüdyo ortamında okunmuş ve cd ile kayıt altına alınarak çalışmaya eklenmiştir. Okunan ezanlar notaya alınarak, makamları ile ilgili bilgiler verilmiş ve kayıtla...

  20. Towards the development of a rapid, portable, surface enhanced Raman spectroscopy based cleaning verification system for the drug nelarabine.

    Science.gov (United States)

    Corrigan, Damion K; Salton, Neale A; Preston, Chris; Piletsky, Sergey

    2010-09-01

    Cleaning verification is a scientific and economic problem for the pharmaceutical industry. A large amount of potential manufacturing time is lost to the process of cleaning verification. This involves the analysis of residues on spoiled manufacturing equipment, with high-performance liquid chromatography (HPLC) being the predominantly employed analytical technique. The aim of this study was to develop a portable cleaning verification system for nelarabine using surface enhanced Raman spectroscopy (SERS). SERS was conducted using a portable Raman spectrometer and a commercially available SERS substrate to develop a rapid and portable cleaning verification system for nelarabine. Samples of standard solutions and swab extracts were deposited onto the SERS active surfaces, allowed to dry and then subjected to spectroscopic analysis. Nelarabine was amenable to analysis by SERS and the necessary levels of sensitivity were achievable. It is possible to use this technology for a semi-quantitative limits test. Replicate precision, however, was poor due to the heterogeneous drying pattern of nelarabine on the SERS active surface. Understanding and improving the drying process in order to produce a consistent SERS signal for quantitative analysis is desirable. This work shows the potential application of SERS for cleaning verification analysis. SERS may not replace HPLC as the definitive analytical technique, but it could be used in conjunction with HPLC so that swabbing is only carried out once the portable SERS equipment has demonstrated that the manufacturing equipment is below the threshold contamination level.

    1. Development and Applications of Portable Gas Chromatography-Mass Spectrometry for Emergency Responders, the Military, and Law-Enforcement Organizations.

      Science.gov (United States)

      Leary, Pauline E; Dobson, Gareth S; Reffner, John A

      2016-05-01

      Portable gas chromatography-mass spectrometry (GC-MS) systems are being deployed for field use, and are designed with this goal in mind. Performance characteristics of instruments that are successful in the field are different from those of equivalent technologies that are successful in a laboratory setting. These field-portable systems are extending the capabilities of the field user, providing investigative leads and confirmatory identifications in real time. Many different types of users benefit from the availability of this technology including emergency responders, the military, and law-enforcement organizations. This manuscript describes performance characteristics that are important for field-portable instruments, especially field-portable GC-MS systems, and demonstrates the value of this equipment to the disciplines of explosives investigations, fire investigations, and counterfeit-drug detection. This paper describes the current state of portable GC-MS technology, including a review of the development of portable GC-MS, as well as a demonstration of the value of this capability using different examples. © The Author(s) 2016.

    2. Quality assurance in the enriched uranium operations NDA facility

      Energy Technology Data Exchange (ETDEWEB)

      May, P.K.; Ceo, R.N. [Oak Ridge Y-12 Plant, TN (United States)

      1997-11-01

      The Nondestructive Analysis (NDA) Facility at the Oak Ridge Y-12 Plant has characterized process wastes for Enriched Uranium Operations since 1978. Since that time, over 50,000 items have been analyzed. Analysis results are used to determine whether or not recovery of uranium from process wastes is economically feasible. Our instrument complement includes one large segmented gamma scanner (SGS), two smaller SGS, two solution assay systems (SAS), and Active Well Coincidence Counter (AWCC). The large SGS is used for analyzing High Efficiency Particulate Air (HEPA) filters ant 208-L drums filled with combustible contaminated waste. The smaller SGS are used to analyze 4-L containers of ash and leached residues. The SAS are used to analyze 125 ml bottles of aqueous or organic waste solutions that may contain uranium. The gamma-based NDA techniques are used to identify which process wastes can be discarded, and which must be recycled. The AWCC is used to analyze high-density materials which are not amenable to gamma-ray analysis. 1 ref., 4 figs.

    3. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

      International Nuclear Information System (INIS)

      Hodge, Chris A.

      2007-01-01

      Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

    4. Nondestructive assay system for use in decommissioning a plutonium-handling facility

      International Nuclear Information System (INIS)

      Roche, C.T.; Vronich, J.J.; Bellinger, F.O.; Perry, R.B.

      1979-07-01

      Argonne National Laboratory is decommissioning a facility used to fabricate reactor fuel elements. The equipment is contaminated with alpha emitters at levels up to 10 12 dpm/100 cm 2 . The objective of decontamination is to reduce the TRU concentrations below 10 nCi/g of waste. A portable NDA procedure using NaI(T1) gamma-spectrometric techniques was selected to measure the residual Pu and 241 Am in the glove boxes. Assays were performed at different stages in the decontamination process to estimate the detection system sensitivity and the effectiveness of the cleaning efforts

    5. Environmental dose measurement with microprocessor based portable TLD reader

      International Nuclear Information System (INIS)

      Deme, S.; Apathy, I.; Feher, I.

      1996-01-01

      Application of TL method for environmental gamma-radiation dosimetry involves uncertainty caused by the dose collected during the transport from the point of annealing to the place of exposure and back to the place of evaluation. Should an accident occur read out is delayed due to the need to transport to a laboratory equipped with a TLD reader. A portable reader capable of reading out the TL dosemeter at the place of exposure ('in situ TLD reader') eliminates the above mentioned disadvantages. We have developed a microprocessor based portable TLD reader for monitoring environmental gamma-radiation doses and for on board reading out of doses on space stations. The first version of our portable, battery operated reader (named Pille - 'butterfly') was made at the beginning of the 80s. These devices used CaSO 4 bulb dosemeters and the evaluation technique was based on analogue timing circuits and analogue to digital conversion of the photomultiplier current with a read out precision of 1 μGy and a measuring range up to 10 Gy. The measured values were displayed and manually recorded. The version with an external power supply was used for space dosimetry as an onboard TLD reader

    6. Portable Exhauster Position Paper

      International Nuclear Information System (INIS)

      KRISKOVICH, J.R.

      1999-01-01

      This document identifies the tasks that are involved in preparing the ''standby'' portable exhauster to support Interim Stabilization's schedule for saltwell pumping. A standby portable exhaust system will be assigned to any facility scheduled to be saltwell pumped with the exception of 241-S farm, 241-SX farm or 241-T farm. The standby portable exhauster shall be prepared for use and placed in storage. The standby portable exhaust system shall be removed from storage and installed to ventilate tanks being pumped that reach 25% LFL. There are three tasks that are evaluated in this document. Each task shall be completed to support portable exhaust system installation and operation. They are: Pre Installation Task; Portable Exhaust System Storage Task; and Portable Exhaust System Installation and Operation Task

    7. A Study on Immersion and Presence of a Portable Hand Haptic System for Immersive Virtual Reality

      OpenAIRE

      Kim, Mingyu; Jeon, Changyu; Kim, Jinmo

      2017-01-01

      This paper proposes a portable hand haptic system using Leap Motion as a haptic interface that can be used in various virtual reality (VR) applications. The proposed hand haptic system was designed as an Arduino-based sensor architecture to enable a variety of tactile senses at low cost, and is also equipped with a portable wristband. As a haptic system designed for tactile feedback, the proposed system first identifies the left and right hands and then sends tactile senses (vibration and hea...

    8. Analysis of historical delta values for IAEA/LANL NDA training courses

      International Nuclear Information System (INIS)

      Geist, William; Santi, Peter; Swinhoe, Martyn; Bonner, Elisa

      2009-01-01

      The Los Alamos National Laboratory (LANL) supports the International Atomic Energy Agency (IAEA) by providing training for IAEA inspectors in neutron and gamma-ray Nondestructive Assay (NDA) of nuclear material. Since 1980, all new IAEA inspectors attend this two week course at LANL gaining hands-on experience in the application of NDA techniques, procedures and analysis to measure plutonium and uranium nuclear material standards with well known pedigrees. As part of the course the inspectors conduct an inventory verification exercise. This exercise provides inspectors the opportunity to test their abilities in performing verification measurements using the various NDA techniques. For an inspector, the verification of an item is nominally based on whether the measured assay value agrees with the declared value to within three times the historical delta value. The historical delta value represents the average difference between measured and declared values from previous measurements taken on similar material with the same measurement technology. If the measurement falls outside a limit of three times the historical delta value, the declaration is not verified. This paper uses measurement data from five years of IAEA courses to calculate a historical delta for five non-destructive assay methods: Gamma-ray Enrichment, Gamma-ray Plutonium Isotopics, Passive Neutron Coincidence Counting, Active Neutron Coincidence Counting and the Neutron Coincidence Collar. These historical deltas provide information as to the precision and accuracy of these measurement techniques under realistic conditions.

    9. Small Portable Analyzer Diagnostic Equipment (SPADE) Program -- Diagnostic Software Validation

      Science.gov (United States)

      1984-07-01

      Electronic Equipment Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference Electromagnetic...ONLY. ORIENTATION OF DEFECT LOOKING HHO QIlILL: t -ed’-o· Significant efforts were expended to simulate spalling failures associated with naturally

    10. 47 CFR 80.225 - Requirements for selective calling equipment.

      Science.gov (United States)

      2010-10-01

      ... Commission will not accept new applications (but will continue to process then-pending applications) for certification of non-portable DSC equipment that does not meet the requirements of ITU-R Recommendation M.493-11... Commission will not accept new applications (but will continue to process then-pending applications) for...

    11. The establishment of a portable high sensitivity exhaled thoron activity measurement system

      International Nuclear Information System (INIS)

      Chen, Xing-an; Cheng, Yong-e

      2008-01-01

      A portable system, using electrostatic collection, for the measurement of exhaled thoron activity in humans is described, together with the basic theory, equipment, calibration procedures, measurement and the preliminary use. The portable system built on experience at the Argonne National Laboratory to achieve a reduction in measurement time from 30 hours to 200 minutes, and to increase the total efficiency of the system from 50%(ANL) to 55% with a minimum detection limit decreased to 0.007 Bq (zero activity± σ). The total standard error of this system is 47% for a thorium lung burden of 0.22 Bq. The average background of this scintillation detector was 0.003 counts/min. (author)

    12. Water analysis in Londrina, PR, using a portable EDXRF system

      International Nuclear Information System (INIS)

      Melquiades, Fabio L.; Silva, Wislley D.; Parreira, Paulo S.; Lopes, Fabio; Appoloni, Carlos R.

      2009-01-01

      The use of Energy Dispersive X-Ray Fluorescence (EDXRF) for analysis of environmental samples has gained expressive attention in the last years. With the objective of identification and quantification of heavy metals in water, EDXRF methodology with portable equipment was employed. The work consisted on the use of a portable EDXRF system constituted by a X-ray tube to excite the samples, a Si-Pin detector, a holder for the excitation-detection system and samples positioning, with the standard data acquisition electronics to register the spectra. The samples were filtered in ester cellulose membranes for suspended particulate matter retention. After this, Ammonium Pyrrolidine Dithiocarbamate (APDC) precipitation methodology was applied for sample preconcentration with posterior filtering in membranes. So, the dissolved and non dissolved metal fractions were determined separately. The detection limits were, in mg L -1 : 0.006 (Fe), 0.015 (Co), 0.004 (Cu), 0.002 (Zn), 0.004 (Se) and 0.005 (Pb), with 5% deviations for 95% of confidence. Considering all the sampling locations, it was possible to quantify the following range of concentrations, in mg L -1 : Ca (0.043 - 0.021), Ti (0.137 - 0.014), Mn (0.052 - 0.008), Fe (1.66 - 0.035), Ni (0.012 - 0.010), Cu (0.010 - 0.007), Zn (0.070 - 0.007) and Pb (0.85 - 1.01). The results presented relative deviation from 5% to 22%, within 95% of confidence level, which is considered very satisfactory when using portable equipment. In 4 h of field work it was possible to filter 14 membranes and measure around 16 samples. (author)

    13. The use of portable shields in industrial radiography

      International Nuclear Information System (INIS)

      Oliveira e Silva, J.A. de.

      1988-01-01

      This paper shows techniques actually used to reduce radiations exposure taxes during examinations execution by gamma radiography in regions of high population density. A portable equipment of radiation shield for using in exams by gamma radiography in pipelines, that is an adjustable device in an object body that will be examined, joining a measured collimator and a shield geometrically arranged so that the radiation restrict to impress the radiographic film used in examination without reaching people, objects or self-movings injurious that are nearness. (C.M.) [pt

    14. Development of portable HPGe spectrometer for in situ measurements

      Directory of Open Access Journals (Sweden)

      Kail Artjoms

      2015-01-01

      Full Text Available In situ applications require a very high level of portability of high-resolution spectrometric equipment. Usage of HPGe detectors for radioactivity measurements in the environment or for nuclear safeguard applications, to combat illicit trafficking of nuclear materials or uranium and plutonium monitoring in nuclear wastes, has become a norm in the recent years. Portable HPGe-based radionuclide spectrometer with electrical cooling has lately appeared on the market for in situ applications. At the same time deterioration of energy resolution associated with vibrations produced by cryocooler or high weight of the instrument, short time of autonomous operation and high price of these spectrometers are limiting their usage in many cases. In this paper we present development results of ultra compact hand held all-in-one spectrometer for in situ measurements based on HPGe detector cooled by liquid nitrogen without listing the above disadvantages.

    15. Fault Detection, Isolation and Recovery (FDIR) Portable Liquid Oxygen Hardware Demonstrator

      Science.gov (United States)

      Oostdyk, Rebecca L.; Perotti, Jose M.

      2011-01-01

      The Fault Detection, Isolation and Recovery (FDIR) hardware demonstration will highlight the effort being conducted by Constellation's Ground Operations (GO) to provide the Launch Control System (LCS) with system-level health management during vehicle processing and countdown activities. A proof-of-concept demonstration of the FDIR prototype established the capability of the software to provide real-time fault detection and isolation using generated Liquid Hydrogen data. The FDIR portable testbed unit (presented here) aims to enhance FDIR by providing a dynamic simulation of Constellation subsystems that feed the FDIR software live data based on Liquid Oxygen system properties. The LO2 cryogenic ground system has key properties that are analogous to the properties of an electronic circuit. The LO2 system is modeled using electrical components and an equivalent circuit is designed on a printed circuit board to simulate the live data. The portable testbed is also be equipped with data acquisition and communication hardware to relay the measurements to the FDIR application running on a PC. This portable testbed is an ideal capability to perform FDIR software testing, troubleshooting, training among others.

    16. Code of practice and design principles for portable and transportable radiological protection systems

      International Nuclear Information System (INIS)

      Wells, F.H.; Powell, R.G.

      1980-10-01

      The Code of Practice and design principles for portable and transportable radiological protection systems are presented in three parts. Part 1 specifies the requirement for Radiological Protection Instrumentation (RPI) including operational characteristics and the effects of both a radiation and non-radiation environment. Part 2 satisfies the requirement for RPI equipment as regards the overall design, the availability, the reliability, the information display, the human factors, the power supplies, the manufacture and quality assurance, the testing and the cost. Part 3 deals with the supply, location and operation of the RPI equipment. (U.K.)

    17. Implementation of an Integrated, Portable Transformer Condition Monitoring Instrument in the Classroom and On-Site

      Science.gov (United States)

      Chatterjee, B.; Dey, D.; Chakravorti, S.

      2010-01-01

      The development of integrated, portable, transformer condition monitoring (TCM) equipment for classroom demonstrations as well as for student exercises conducted in the field is discussed. Demonstrations include experimentation with real-world transformers to illustrate concepts such as polarization and depolarization current through oil-paper…

    18. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) ; Guidance on the scientific requirements for health claims related to physical performance

      DEFF Research Database (Denmark)

      Tetens, Inge

      The Panel on Dietetic Products, Nutrition and Allergies (NDA) was asked by the European Food Safety Authority (EFSA) to draft guidance on scientific requirements for health claims related to physical performance. This guidance has been drawn from scientific opinions of the NDA Panel on such health...... claims. Thus, this guidance document represents the views of the NDA Panel based on the experience gained to date with the evaluation of health claims in this area. It is not intended that the document should include an exhaustive list of beneficial effects and studies/outcome measures which...

    19. Application of wireless LAN technology to remote monitoring for inspection equipment

      International Nuclear Information System (INIS)

      Ishiyama, Koichi; Kimura, Takashi; Miura, Yasushi; Yamaguchi, Katsuhiro; Kabuki, Toshihide

      2011-01-01

      To support inspections under an Integrated Safeguards regime into Tokai Reprocessing Plant (TRP), the IAEA suggested making use of Remote Monitoring (RM) capabilities to the inspection equipment (surveillance camera and NDA systems) installed in the spent fuel storage area at TRP. Since TRP had no pre-prepared cabling infrastructure for data transmission in the spent fuel storage area, the option of wireless LAN was chosen over the telephone line due to its lower installation costs. Feasibility studies and tests were performed by TRP on communication and particularly on long-term continuous communication using wireless LAN equipment composed of APs (AP: Access Point) and the external antennas for introducing wireless LAN technology to RM. As a result it was recognized that wireless LAN has enough ability to communicate for long periods of time and consequently the IAEA installed the AP and the external antenna to each inspection equipment and the wireless LAN technology was applied for RM. In this paper, the summary of each test and the results are reported. (author)

    20. Field nondestructive assay measurements as applied to process inventories

      International Nuclear Information System (INIS)

      Westsik, G.A.

      1979-08-01

      An annual process equipment holdup inventory measurement program for a plutonium processing plant was instituted by Rockwell Hanford Operations (Rockwell) at Richland, Washington. The inventories, performed in 1977 and 1978, were designed to improve plutonium accountability and control. The inventory method used field nondestructive assay (NDA) measurement techniques with portable electronics and sodium iodide detectors. Access to and movement of plutonium in work areas was curtailed during the inventory process using administrative controls. Comparison of the two annual inventories showed good reproducibility of results within the calculated error ranges. For items where no plutonium movement occurred and which contained greater than 20 grams plutonium, the average measurement difference between the two inventories was 22%. The procedures and equipment used and the operational experience from the inventories are described

    1. An experimental evaluation of a new designed apparatus (NDA) for the rapid measurement of impaired motor function in rats.

      Science.gov (United States)

      Jarrahi, M; Sedighi Moghadam, B; Torkmandi, H

      2015-08-15

      Assessment of the ability of rat to balance by rotarod apparatus (ROTA) is frequently used as a measure of impaired motor system function. Most of these methods have some disadvantages, such as failing to sense motor coordination rather than endurance and as the sensitivity of the method is low, more animals are needed to obtain statistically significant results. We have designed and tested a new designed apparatus (NDA) to measure motor system function in rats. Our system consists of a glass box containing 4 beams which placed with 1cm distance between them, two electrical motors for rotating the beams, and a camera to record the movements of the rats. The RPM of the beams is adjustable digitally between 0 and 50 rounds per minute. We evaluated experimentally the capability of the NDA for the rapid measurement of impaired motor function in rats. Also we demonstrated that the sensitivity of the NDA increases by faster rotation speeds and may be more sensitive than ROTA for evaluating of impaired motor system function. Compared to a previous version of this task, our NDA provides a more efficient method to test rodents for studies of motor system function after impaired motor nervous system. In summary, our NDA will allow high efficient monitoring of rat motor system function and may be more sensitive than ROTA for evaluating of impaired motor system function in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

    2. PAT portable appliance testing : in-service inspection and testing of electrical equipment

      CERN Document Server

      Scaddan, Brian

      2015-01-01

      The Electricity at Work Regulations 1989 requires any electrical system to be constructed, maintained and used in such a manner as to prevent danger. This means that inspection and testing of systems, including portable appliances, is needed in order to determine if maintenance is required. This book explains in clear language what needs to be done and includes expert advice on legislation as well as actual testing. The book contains an appendix providing the electrical fundamentals needed by non-specialists and also has sample questions (with answers) for the C&G 2377 exam. It is also an ideal revision guide for the non-specialist, such as maintenance staff and caretakers who carry out these tasks part-time, alongside their many other duties.

    3. Portable X-ray fluorescence analyzer of high sensitivity using X-ray tube excitation

      International Nuclear Information System (INIS)

      Vatai, E.; Ando, L.

      1982-01-01

      A review of the three main methods of X-ray fluorescence analysis and their problems is given. The attainable accuracy and effectiveness of each method are discussed. The main properties of portable X-ray analyzers required by the industry are described. The results and experiences of R and D activities in ATOMKI (Debrecen, Hungary) for developing portable X-ray analyzers are presented. The only way for increasing the accuracy and decreasing the measuring time is the application of X-ray tube excitation instead of radioactive sources. The new ATOMKI equipment presently under construction and patenting uses X-ray tube excitation; it will increase the accuracy of concentration determination by one order of magnitude. (D.Gy.)

    4. Analysis of Pre-Columbian objetcs from Cupisnique, one of the oldest culture from Perú, using a portable X-ray fluorescence equipment

      Science.gov (United States)

      Bustamante, A.; Cesareo, R.; Brunetti, A.; Rizzutto, M.; Calza, C.; Pereira de Freitas, R.; Holmsquit, U.; Diestra, D.

      2013-12-01

      Cupisnique (2000-200 BC) is one of the first complex societies that developed in the Jetequepeque valley in the "Formative period." It includes several settlements: Puémape on the coast, Limoncarro in middle valley, Montegrande and Tembladera in the upper valley, and Kuntur Wasi in San Pablo. Currently the valley comprises two provinces, Pacasmayo and Chepen in the La Libertad region, north of Lima. Consideration should be given to cupisniques as premetallurgical culture, and the only used metal was gold, which is present in the native state, on the soil surface or shallow, and attracted attention because of color, brightness, weight, ductility, and inalterability. We analyzed three Cupisnique metal objects belonging to the Larco Museum of Lima designated with No. 4 (pectoral), No. 7 (pendant), and No. 12 (bracelet), using a portable energy-dispersive X-ray fluorescence equipment. Mean value for the pectoral were Au (62 %), Ag (23 %), Cu (15 %); for the pendant, Au (81 %), Ag (16.5 %), Cu (2.5 %); and for the bracelet, Au (69.1 %), Ag (20 %), and Cu (10.9 %).

    5. Çevre etiği bağlamında Anadolu sığla ormanları

      OpenAIRE

      ÜRKER, Okan

      2014-01-01

      Doğal kaynak/varlık kullanımı ve yönetiminde toplumsal taleplerin hangi koşullar altında şekillendiğinin ve yönlendirildiğinin tespit edilmesi, buna ilişkin etik talebin ortaya çıkma süreçlerinin izlenmesi, bu bağlamda kamu vicdanının ve kamu yararının oluşmasında ve farklı şekillerde algılanmasında ve içselleştirilmesinde hukuk, politika gibi araçların nasıl kullanıldığının gösterilmesi, tüm bu süreçlerin çevre etiği açısından değerlendirilmesi ve sonucunda toplumsal faydanın ‘doğa ...

    6. The characterization of an economic and portable LED-based photoacoustic imaging system to facilitate molecular imaging

      Directory of Open Access Journals (Sweden)

      Ali Hariri

      2018-03-01

      Full Text Available Photoacoustic imaging (PAI is a non-invasive, high-resolution hybrid imaging modality that combines optical excitation and ultrasound detection. PAI can image endogenous chromophores (melanin, hemoglobin, etc. and exogenous contrast agents in different medical applications. However, most current equipment uses sophisticated and complicated OPO lasers with tuning and stability features inconsistent with broad clinical deployment. As the number of applications of PAI in medicine increases, there is an urgent need to make the imaging equipment more compact, portable, and affordable. Here, portable light emitting diode – based photoacoustic imaging (PLED-PAI was introduced and characterized in terms of system specifications, light source characterizations, photoacoustic spatial/temporal resolution, and penetration. The system uses two LED arrays attached to the sides of a conventional ultrasound transducer. The LED pulse repetition rate is tunable between 1 K Hz, 2 K Hz, 3 K Hz, and 4 K Hz. The axial resolution was 0.268 mm, and the lateral resolution was between 0.55 and 0.59 mm. The system could detect optical absorber (pencil lead at a depth of 3.2 cm and the detection limits of indocyanine green (ICG and methylene blue (MB were 9 μM and 0.78 mM. In vivo imaging of labeled human mesenchymal stem cells was achieved to confirm compatibility with small animal imaging. The characterization we report here may have value to other groups evaluating commercially available photoacoustic imaging equipment. Keywords: Portable photoacoustic imaging, LED, Optoacoustic imaging, Molecular imaging

    7. Applications of non-cryogenic portable EDXRF systems in archaeometry

      International Nuclear Information System (INIS)

      Cesareo, R.; Castellano, A.; Dabrowski, A.

      1996-01-01

      In this paper the most relevant developments in the realisation of portable energy-dispersive X-ray fluorescence (EDXRF) equipments are discussed. In particular, the latest advances in non-cryogenic (Peltier cooled) X-ray detectors and miniaturised X-ray generators are shown. The energy resolution of the new detection systems is adequate to resolve the characteristic X-ray emission lines of contiguous elements. This small size and low power make the system ideal for portable instrumentation and have stimulated the development of small- and low-power X-ray generators which can be used for the excitation of fluorescence radiation in a broad energy range (5-40 keV). Finally, the use of EDXRF related to archaeometric research (pigments in ancient paintings and major elements in the metal alloys) is emphasised. Recent results obtained with new HgI 2 and silicon PIN detector systems combined with miniaturised highly stable air-cooled X-ray generators are described. (orig.)

    8. Nef’î Hakkında Bir Bibliyografya Denemesi An Essay Of Bibliography About Nef’i

      Directory of Open Access Journals (Sweden)

      Halil Sercan KOŞİK

      2013-03-01

      Full Text Available Nef’î who lived in the first half of 17th century was born in Hasankale one of districts of Erzurum. The poet whose real name was Ömer had a life full of struggles but he managed to produce some important works through his life. Nef’î, one of the leading poets of divan poetry was celebrated much at his age and after his death. Such a reputation is originated from the sharpness of his pen, his talent as well as his wit. Nef’î whose usage of praise and satire is extreme is known forhis mastership in using rhythm and rhyme in his poems. While attaching importance to meaning and utterance he tried to use a new language and accomplished that to a great degree. His knowledge of Persian Language and Literature played a considerable role.A lot has been written so far about Nef’î and a great many research exists about his works too. However it is obvious that there will be many works about Nef’î, a productive poet. In this study a classification of Nef’î’s works and scientific studies about him and his works will be presented. Our research focuses to illustrate which part of his works is the center of modern researches and which parts are not. In addition, it is expected that our research will provided useful information to researchers studying Nef’î as a guide for sources regarding him. On yedinci yüzyılın ilk yarısında yaşamış olan Nef’î, Erzurum’un Hasankale ilçesinde doğmuştur. Asıl adı Ömer olan şair, oldukça mücadele dolu bir hayat geçirmiş ve bu hayata aynı zamanda önemli denilebilecek eserler de sığdırabilmeyi başarmıştır. Divan şiirinin önde gelen şairlerden biri olan Nef’î, adından hem yaşadığı dönemde hem de sonrasında çokça söz ettirmiştir. Nef’î’nin böyle bir şöhrete kavuşması onun edebi yeteneği ve kıvrak zekası yanında kaleminin keskin olmasından kaynaklanmaktadır. Övdüğünü çok iyi öven, yerdiğini de çok kötü bir şekilde yeren Nef

    9. Development of ultrasonic inspection equipment using phased array method

      International Nuclear Information System (INIS)

      Kikuchi, Osamu; Yamatoya, Naofumi; Umino, Tomohiro; Baba, Atsushi

      2008-01-01

      This study presents new phased array UT equipments, one is developed as portable type for field inspection and the other is developed for 2D-matrix array (3D Focus-UT). The pulser of square burst wave was adopted for these new equipments to enhance flaw echo amplitude. At over 3 cycles of square burst cycle, the authors confirmed over 10 dB enhancement of bottom echo amplitude. Moreover, a new flaw imaging method using S-SAFT was also adopted for equipments to improve SN ratio and flaw echo resolution in inspection image. The authors verified effects of S-SAFT using side drilled hole specimen, about 2 times of improvement of SN ratio and flaw echo resolution. (author)

    10. Areas and limits of employment of portable EDXRF equipment for in situ investigations

      International Nuclear Information System (INIS)

      Gigante, G.E.; Ricciardi, P.; Ridolfi, St.

      2005-01-01

      The use of mobile spectrometers in the archaeo-metric study of ancient artefacts has become a very common practice over the past few years. It does open methodological questions on the employment of such techniques in a non-destructive manner, i.e. avoiding the damage of the artifact. Some additional methodological questions come by (i) the use of such instrumentation for diagnostic scopes (in which a different approach to the measurement is required) and (ii) the use of the spectrometers in systematic analysis on big number of artefacts, stored in several museums (during experimental campaigns). This paper's aim is to discuss some of this questions, on the basis of the experience in the use of mobile (or Field Portable) systems for Energy Dispersive X-ray Fluorescence (EDXRF) spectroscopy that we have harvested in the last years. Our conclusions mainly regard the precision of measures, which is related both to the positioning of the spectrometer and to the instrument's instability. Also we deal with the more complex problem of the object's matrix not being homogeneous and of how this can affect the response of the measuring system. Moreover, it is discussed the more general question of the use of portable spectrometers and, consequently, of the meaning one can give to the results so obtained. As a matter of fact the use of such systems, which have an intrinsic analytic potential, in a non-destructive manner, frequently creates ambiguities that have not been, sometimes, taken into account with attention by the investigators. Finally some ideas are traced on the development of methodologies which favor a better use of such spectroscopic systems for the analysis of ancient artefacts. (authors)

    11. Portable and fixed monitoring units for tank calibrations and monitoring of process liquids

      International Nuclear Information System (INIS)

      Landat, D.A.; Hunt, B.A.

      1999-01-01

      The development work stems from safeguards support activities carried out at the JRC Ispra, Italy to the inspectorate agencies. A range of measurement equipment covering the needs of the inspector have been designed, developed and tested in both the laboratory and in nuclear facilities. The instruments comprise four units: (1) a portable pressure measurement device, (2) a volume long term monitoring device, (3) an unattended volume measurement system and (4) a level measurement unit. Utilization of the equipment has proven to give independent measurement checks and confirmation of operator's instrumentation and declarations, ensuring continuity of knowledge. (J.P.N.)

    12. Measuring Pu in a glove box using portable NaI and germanium detectors

      International Nuclear Information System (INIS)

      Hankins, D.E.

      1984-01-01

      A NaI crystal or germanium detector inside a portable lead shield can determine the amount of plutonium in a glove box. The number of counts required are defined and the locations outside the box where the detector needs to be positioned are given. The calculated accuracy for measuring the Pu when these locations are used is within +/-30% for most glove boxes. Other factors that may affect this accuracy, such as γ-ray absorption by glove-box materials, self-absorption by Pu, absorption by equipment in the glove box, and the limits of the counting equipment are also discussed

    13. The states of the art of the nondestructive assay of spent nuclear fuel assemblies. A critical review of the Spent Fuel NDA Project of the U.S. Department of Energy's Next Generation Safeguards Initiative

      International Nuclear Information System (INIS)

      Bolind, Alan Michael; Seya, Michio

      2015-12-01

      The state of the art of the nondestructive assay of spent nuclear fuel assemblies is represented by the results of the Spent Fuel Nondestructive Assay Project of the Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy / National Nuclear Security Administration. This report surveys the fourteen advanced nondestructive assay (NDA) techniques that were examined by the NGSI. For each technique, it explains how the technique operates, the NGSI's design of an instrument that uses the technique, how the data are analyzed, and the technique's chief limitations. After this survey of the NDA techniques, the report then discusses and critiques the current paradigm of the practice of NDA of spent fuel assemblies. It shows how the current main problem in the NDA of spent fuel assemblies—namely, an unacceptably large uncertainty in the assay results—is caused primarily by using too few independent NDA measurements. Because the physics of the NDA of spent fuel assemblies is three dimensional, at least three independent NDA measurements are required. Thus, NDA results should be able to be improved dramatically by combining the fourteen advanced NDA techniques plus other existing NDA techniques into appropriate combinations of three techniques. This report evaluates the NGSI's proposed NDA combinations according to these principles. (author)

    14. Space station wardroom habitability and equipment study

      Science.gov (United States)

      Nixon, David; Miller, Christopher; Fauquet, Regis

      1989-01-01

      Experimental designs in life-size mock-up form for the wardroom facility for the Space Station Habitability Module are explored and developed. In Phase 1, three preliminary concepts for the wardroom configuration are fabricated and evaluated. In Phase 2, the results of Phase 1 are combined with a specific range of program design requirements to provide the design criteria for the fabrication of an innovative medium-fidelity mock-up of a wardrobe configuration. The study also focuses on the design and preliminary prototyping of selected equipment items including crew exercise compartments, a meal/meeting table and a portable workstation. Design criteria and requirements are discussed and documented. Preliminary and final mock-ups and equipment prototypes are described and illustrated.

    15. A portable contamination monitor with a numerical display

      International Nuclear Information System (INIS)

      Jones, A.R.

      1980-10-01

      A portable contamination monitor, its performance and application are described. The monitor is equipped with two 15.5 cm 2 'pancake' type Geiger-Mueller counters with thin windows ( 2 ). The summed counting rate is displayed in the range 0.2000 counts/s on a liquid crystal digital voltmeter. Every tenth pulse is signaled by flashing an LED and emitting a short (0.1 s) pulse of sound. The efficiencies for detecting a variety of α-, β- and γ- emitters have been measured and are reported. Data on the effects of varying battery voltage and temperature are also reported. (auth)

    16. Acceptance test procedure for a portable, self-contained nitrogen supply

      International Nuclear Information System (INIS)

      Kostelnik, A.J.

      1994-01-01

      This Acceptance Test Procedure (ATP) will document compliance with the requirements of WHC-S-0249 Rev. 1 and ECN 606112. The equipment being tested is a Portable, Self-Contained Nitrogen Supply. The unit was purchased as a Design and Fabrication procurement activity. The Functional Test was written by the Seller and is contained in Appendix A. The Functional test will be performed by the Seller with representatives of the Westinghouse Hanford Company performing inspection and witnessing the functional test at the Seller's location

    17. How the NDA Provides Transparency and Visibility of the Technical Deliverability of the R and D Programme - 13303

      International Nuclear Information System (INIS)

      Seed, Ian; James, Paula; Brownridge, Melanie; McMinn, Mervin

      2013-01-01

      The Nuclear Decommissioning Authority (NDA) was created under the UK Energy Act 2004 to ensure the UK historic civil public sector nuclear legacy sites are decommissioned safely, securely, cost effectively and in ways that protect the environment. The delivery will involve carrying out many unique projects within a high hazard environment requiring the very highest standards in safety, security and environmental management. Unique problems require unique solutions and there is a substantial amount of research and development required for each project. The NDA's R and D strategic objective is to ensure that delivery of the NDA's mission is technically underpinned by sufficient and appropriate research and development. This drives a requirement to provide transparency and visibility of the technical deliverability of the programme through the technical baseline and accompanying research and development requirements. The NDA need to have confidence in the technical deliverability of the Site License Companies (SLCs) plans, provide overall visibility of R and D across the NDA Estate and ensure that appropriate R and D is being carried out in a timely manner. They need to identify where coordinated R and D programmes may be advantageous as a result of common needs, risks and opportunities and ensure key R and D needs across NDA are identified, prioritised and work programmes are costed and scheduled in the Lifetime Plans for individual sites and SLCs. Evidence of the Site License Company's approach and their corresponding technical underpinning programmes is achieved through submission of a number of outputs collectively known as TBuRDs (Technical Baseline and Underpinning Research and Development Requirements). This paper is a summary of the information generated by an independent review of those TBuRDs. It highlights some of the key messages, synergies and common R and D activities across the estate. It demonstrates the value of a consistent approach to collecting R

    18. Ruggedized Portable Instrumentation Package for Marine Mammal Evoked Potential Hearing Measurements (DURIP)

      Science.gov (United States)

      2011-09-30

      NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Hawaii Institute of Marine Biology,Marine Mammal...Program Hawaii Institute of Marine Biology P.O. Box 1106 Kailua, Hawaii 96734 phone: (808) 247-5297 fax: (808) 247-5831 email: nachtiga...portable equipment was used at the Hilo Stranding Center to obtain the audiograms. Ready and available for RIMPAC excercises. 2 IMPACT

    19. Methodology for NDA performance assessment

      International Nuclear Information System (INIS)

      Cuypers, M.; Franklin, M.; Guardini, S.

      1986-01-01

      In the framework of the RandD programme of the Joint Research Centre of the Commission of the European Communities, a considerable effort is being dedicated to performance assessment of NDA techniques taking account of field conditions. By taking account of field conditions is meant measurement samples of the size encountered in practice and training which allows inspectors to design cost efficient verification plans for the real situations encountered in the field. Special laboratory facilities referred to as PERLA are being constructed for this purpose. These facilities will be used for measurement experiments and for training. In this paper, performance assessment is discussed under the headings of measurement capability and in-field effectiveness. Considerable emphasis is given to the role of method specific measurement error models. The authors outline the advantages of giving statistical error models a sounder basis in the physical phenomenology of the measurement method

    20. Peynir Yapımında Mikrobiyal Renet Kullanımı

      Directory of Open Access Journals (Sweden)

      Mehmet Karapınar

      2015-02-01

      Full Text Available Peynir yapımında süt koagulantı olarak buzağı reneti yerine kullanılmak üzere proteazlar üzerine yapılan çalışmalar son yıllarda yoğunluk kazanmıştır. Günümüzde buzağı reneti standart bir süt koagulantı olarak önemini sürdürmekteyse de, şirden mayası üretimi her yıl giderek gereksinimi karşılayamaz duruma gelmektedir. Bunun sonucu olarak yeni renet kaynakları arasında yoğunlaşmış ve günümüzde Mucor pusillus, M. miehei, Endothia parasitica küf türlerinden elde edilen üç fungal enzim ile Bacillus cereus bakterisinden elde edilen bir bakteriyel enzim ticari olarak üretilmeye başlanmıştır.

    1. Portable treatment systems study

      Energy Technology Data Exchange (ETDEWEB)

      Sherick, M.J.; Schwinkendorf, W.E.; Bechtold, T.E.; Cole, L.T.

      1997-03-01

      In developing their Site Treatment Plans (STPs), many of the Department of Energy installations identified some form of portable treatment, to facilitate compliant disposition of select mixed low-level wastestreams. The Environmental Management Office of Science and Technology requested that a systems study be performed to better define the potential role of portable treatment with respect to mixed low-level waste, highlight obstacles to implementation, and identify opportunities for future research and development emphasis. The study was performed by first establishing a representative set of mixed waste, then formulating portable treatment system concepts to meet the required processing needs for these wastes. The portable systems that were conceptualized were evaluated and compared to a fixed centralized treatment alternative. The system evaluations include a life-cycle cost analysis and an assessment of regulatory, institutional, and technical issues associated with the potential use of portable systems. The results of this study show that when all costs are included, there are no significant cost differences between portable systems and fixed systems. However, it is also emphasized that many uncertainties exist that could impact the cost of implementing portable treatment systems. Portable treatment could be made more attractive through private sector implementation, although there is little economic incentive for a commercial vendor to develop small, specialized treatment capabilities with limited applicability. Alternatively, there may also be valid reasons why fixed units cannot be used for some problematic wastestreams. In any event, there are some site-specific problems that still need to be addressed, and there may be some opportunity for research and development to make a positive impact in these areas.

    2. Portable treatment systems study

      International Nuclear Information System (INIS)

      Sherick, M.J.; Schwinkendorf, W.E.; Bechtold, T.E.; Cole, L.T.

      1997-03-01

      In developing their Site Treatment Plans (STPs), many of the Department of Energy installations identified some form of portable treatment, to facilitate compliant disposition of select mixed low-level wastestreams. The Environmental Management Office of Science and Technology requested that a systems study be performed to better define the potential role of portable treatment with respect to mixed low-level waste, highlight obstacles to implementation, and identify opportunities for future research and development emphasis. The study was performed by first establishing a representative set of mixed waste, then formulating portable treatment system concepts to meet the required processing needs for these wastes. The portable systems that were conceptualized were evaluated and compared to a fixed centralized treatment alternative. The system evaluations include a life-cycle cost analysis and an assessment of regulatory, institutional, and technical issues associated with the potential use of portable systems. The results of this study show that when all costs are included, there are no significant cost differences between portable systems and fixed systems. However, it is also emphasized that many uncertainties exist that could impact the cost of implementing portable treatment systems. Portable treatment could be made more attractive through private sector implementation, although there is little economic incentive for a commercial vendor to develop small, specialized treatment capabilities with limited applicability. Alternatively, there may also be valid reasons why fixed units cannot be used for some problematic wastestreams. In any event, there are some site-specific problems that still need to be addressed, and there may be some opportunity for research and development to make a positive impact in these areas

    3. Inspector-instrument interface in portable NDA instrumentation

      International Nuclear Information System (INIS)

      Halbig, J.K.; Klosterbuer, S.F.

      1981-01-01

      Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

    4. Inspector-instrument interface in portable NDA instrumentation

      International Nuclear Information System (INIS)

      Halbig, J.K.; Klosterbuer, S.F.

      1981-01-01

      Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

    5. 30 CFR 75.703-3 - Approved methods of grounding offtrack mobile, portable and stationary direct-current machines.

      Science.gov (United States)

      2010-07-01

      ..., portable and stationary direct-current machines. 75.703-3 Section 75.703-3 Mineral Resources MINE SAFETY... stationary direct-current machines. In grounding offtrack direct-current machines and the enclosures of their... requirements: (1) Installation of silicon diodes shall be restricted to electric equipment receiving power from...

    6. Play Equipment, Physical Activity Opportunities, and Children's Activity Levels at Childcare

      Directory of Open Access Journals (Sweden)

      Jessica S. Gubbels

      2012-01-01

      Full Text Available This study investigated the association between physical activity facilities at childcare (e.g., play equipment and physical activity of 2- and 3-year olds. Observations of physical activity intensity were performed among 175 children at 9 childcare centers in The Netherlands, using the OSRAC-P. The physical activity facilities were assessed for indoors and outdoors separately, using the EPAO instrument. Regular (single-level multivariate and multilevel linear regression analyses examined the association of the facilities and child characteristics (age and sex with children's activity levels. Various physical activity facilities were available in all childcare centers (e.g., balls. Riding toys and a small playing area were associated with lower indoor physical activity levels. Outdoor physical activity levels were positively associated with the availability of portable jumping equipment and the presence of a structured track on the playground. Portable slides, fixed swinging equipment, and sandboxes were negatively associated with outdoor activity levels. In addition, the 3-year old children were more active outdoors than the 2-year olds. In conclusion, not all physical activity facilities at childcare were indeed positively associated with children's activity levels. The current findings provide concrete leads for childcare providers regarding which factors they can improve in the physical environment to facilitate children's physical activity.

    7. Development of a portable system to test area monitors for neutrons

      International Nuclear Information System (INIS)

      Souza, Luciane de Rezende

      2011-02-01

      The objective is to develop a portable system to test the reliability in terms of calibration of area monitors for neutrons. For the production of this system, thickness and location of the source within the system were simulated using the code of radiation transport MCNP5. The thicknesses were set for a 241 Am-Be source with an activity of 395 mCi, which will be in a polyethylene cylinder which will provide a ambient dose equivalent rate chosen through the points of calibration settings' used by the Laboratory of Neutrons (IRD / CNEN). The results obtained in this study show the feasibility of mounting the portable system as a tool to test the area monitors for neutrons, which will provide the user of neutron area monitors to check the instrument's response in the same field of operation, thus avoiding the use of an inadequate equipment. (author)

    8. Methodology for cost analysis of film-based and filmless portable chest systems

      Science.gov (United States)

      Melson, David L.; Gauvain, Karen M.; Beardslee, Brian M.; Kraitsik, Michael J.; Burton, Larry; Blaine, G. James; Brink, Gary S.

      1996-05-01

      Many studies analyzing the costs of film-based and filmless radiology have focused on multi- modality, hospital-wide solutions. Yet due to the enormous cost of converting an entire large radiology department or hospital to a filmless environment all at once, institutions often choose to eliminate film one area at a time. Narrowing the focus of cost-analysis may be useful in making such decisions. This presentation will outline a methodology for analyzing the cost per exam of film-based and filmless solutions for providing portable chest exams to Intensive Care Units (ICUs). The methodology, unlike most in the literature, is based on parallel data collection from existing filmless and film-based ICUs, and is currently being utilized at our institution. Direct costs, taken from the perspective of the hospital, for portable computed radiography chest exams in one filmless and two film-based ICUs are identified. The major cost components are labor, equipment, materials, and storage. Methods for gathering and analyzing each of the cost components are discussed, including FTE-based and time-based labor analysis, incorporation of equipment depreciation, lease, and maintenance costs, and estimation of materials costs. Extrapolation of data from three ICUs to model hypothetical, hospital-wide film-based and filmless ICU imaging systems is described. Performance of sensitivity analysis on the filmless model to assess the impact of anticipated reductions in specific labor, equipment, and archiving costs is detailed. A number of indirect costs, which are not explicitly included in the analysis, are identified and discussed.

    9. Novel wideband MIMO antennas that can cover the whole LTE spectrum in handsets and portable computers.

      Science.gov (United States)

      Sanad, Mohamed; Hassan, Noha

      2014-01-01

      A dual resonant antenna configuration is developed for multistandard multifunction mobile handsets and portable computers. Only two wideband resonant antennas can cover most of the LTE spectrums in portable communication equipment. The bandwidth that can be covered by each antenna exceeds 70% without using any matching or tuning circuits, with efficiencies that reach 80%. Thus, a dual configuration of them is capable of covering up to 39 LTE (4G) bands besides the existing 2G and 3G bands. 2×2 MIMO configurations have been also developed for the two wideband antennas with a maximum isolation and a minimum correlation coefficient between the primary and the diversity antennas.

    10. [The development of a portable life support device for transporting pre-hospital critically ill patients].

      Science.gov (United States)

      Song, Zhen-xing; Wu, Tai-hu; Meng, Xing-ju; Lu, Heng-zhi; Zheng, Jie-wen; Wang, Hai-tao

      2012-06-01

      To describe a portable life support device for transportation of pre-hospital patients with critical illness. The characteristics and requirements for urgent management during transportation of critically ill patients to a hospital were analyzed. With adoption of the original equipment, with the aid of staple of the art soft ware, the overall structure, its installation, fixation, freedom from interference, operational function were studied, and the whole system of life support and resuscitation was designed. The system was composed by different modules, including mechanical ventilation, transfusion, aspiration, critical care, oxygen supply and power supply parts. The system could be fastened quickly to a stretcher to form portable intensive care unit (ICU), and it could be carried by different size vehicles to provide nonstop treatment by using power supply of the vehicle, thus raising the efficiency of urgent care. With characteristics of its small size, lightweight and portable, the device is particularly suitable for narrow space and extreme environment.

    11. On-Site Molecular Detection of Soil-Borne Phytopathogens Using a Portable Real-Time PCR System.

      Science.gov (United States)

      DeShields, Joseph B; Bomberger, Rachel A; Woodhall, James W; Wheeler, David L; Moroz, Natalia; Johnson, Dennis A; Tanaka, Kiwamu

      2018-02-23

      On-site diagnosis of plant diseases can be a useful tool for growers for timely decisions enabling the earlier implementation of disease management strategies that reduce the impact of the disease. Presently in many diagnostic laboratories, the polymerase chain reaction (PCR), particularly real-time PCR, is considered the most sensitive and accurate method for plant pathogen detection. However, laboratory-based PCRs typically require expensive laboratory equipment and skilled personnel. In this study, soil-borne pathogens of potato are used to demonstrate the potential for on-site molecular detection. This was achieved using a rapid and simple protocol comprising of magnetic bead-based nucleic acid extraction, portable real-time PCR (fluorogenic probe-based assay). The portable real-time PCR approach compared favorably with a laboratory-based system, detecting as few as 100 copies of DNA from Spongospora subterranea. The portable real-time PCR method developed here can serve as an alternative to laboratory-based approaches and a useful on-site tool for pathogen diagnosis.

    12. Portable Medical Laboratory Applications Software

      OpenAIRE

      Silbert, Jerome A.

      1983-01-01

      Portability implies that a program can be run on a variety of computers with minimal software revision. The advantages of portability are outlined and design considerations for portable laboratory software are discussed. Specific approaches for achieving this goal are presented.

    13. NDA issues with RFETS vitrified waste forms

      International Nuclear Information System (INIS)

      Hurd, J.; Veazey, G.

      1998-01-01

      A study was conducted at Los Alamos National Laboratory (LANL) for the purpose of determining the feasibility of using a segmented gamma scanner (SGS) to accurately perform non-destructive analysis (NDA) on certain Rocky Flats Environmental Technology Site (RFETS) vitrified waste samples. This study was performed on a full-scale vitrified ash sample prepared at LANL according to a procedure similar to that anticipated to be used at RFETS. This sample was composed of a borosilicate-based glass frit, blended with ash to produce a Pu content of ∼1 wt %. The glass frit was taken to a degree of melting necessary to achieve a full encapsulation of the ash material. The NDA study performed on this sample showed that SGSs with either 1/2- or 2-inch collimation can achieve an accuracy better than 6 % relative to calorimetry and γ-ray isotopics. This accuracy is achievable, after application of appropriate bias corrections, for transmissions of about 1/2 % through the waste form and counting times of less than 30 minutes. These results are valid for ash material and graphite fines with the same degree of plutonium particle size, homogeneity, sample density, and sample geometry as the waste form used to obtain the results in this study. A drum-sized thermal neutron counter (TNC) was also included in the study to provide an alternative in the event the SGS failed to meet the required level of accuracy. The preliminary indications are that this method will also achieve the required accuracy with counting times of ∼30 minutes and appropriate application of bias corrections. The bias corrections can be avoided in all cases if the instruments are calibrated on standards matching the items

    14. Developing Spent Fuel Assembly for Advanced NDA Instrument Calibration - NGSI Spent Fuel Project

      Energy Technology Data Exchange (ETDEWEB)

      Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gauld, Ian C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Banfield, James [GE Hitachi Nuclear Energy, Wilmington, NC (United States); Skutnik, Steven [Univ. of Tennessee, Knoxville, TN (United States)

      2014-02-01

      This report summarizes the work by Oak Ridge National Laboratory to investigate the application of modeling and simulation to support the performance assessment and calibration of the advanced nondestructive assay (NDA) instruments developed under the Next Generation Safeguards Initiative Spent Fuel (NGSI-SF) Project. Advanced NDA instrument calibration will likely require reference spent fuel assemblies with well-characterized nuclide compositions that can serve as working standards. Because no reference spent fuel standard currently exists, and the practical ability to obtain direct measurement of nuclide compositions using destructive assay (DA) measurements of an entire fuel assembly is prohibitive in the near term due to the complexity and cost of spent fuel experiments, modeling and simulation will be required to construct such reference fuel assemblies. These calculations will be used to support instrument field tests at the Swedish Interim Storage Facility (Clab) for Spent Nuclear Fuel.

    15. Eskişehir koşullarında yetiştirilen Reyhan (Ocimum basilicum L.) bitkisinin bazı bitkisel özelliklerin ve diurnal varyabilitesinin belirlenmesi

      OpenAIRE

      Kulan, Engin Gökhan

      2013-01-01

      Bu çalışma Eskişehir Osmangazi Üniversitesi Ziraat Fakültesi Tarla Bitkileri Bölümü deneme alanında 2010 yılında yürütülmüştür. Denemede Eskişehir ekolojik koşullarında yetiştirilen reyhan (Ocimum basilicum L.) bitkisinin verim ve verim özellikleri ile farklı biçim saatlerinin reyhanın uçucu yağı ve uçucu yağ bileşimi üzerine olan etkileri incelenmiştir. Tesadüf bloklarında bölünmüş parseller deneme desenine göre 3 tekerrürlü olarak kurulan denemede reyhan bitkileri çiçeklen...

    16. Portable computing - A fielded interactive scientific application in a small off-the-shelf package

      Science.gov (United States)

      Groleau, Nicolas; Hazelton, Lyman; Frainier, Rich; Compton, Michael; Colombano, Silvano; Szolovits, Peter

      1993-01-01

      Experience with the design and implementation of a portable computing system for STS crew-conducted science is discussed. Principal-Investigator-in-a-Box (PI) will help the SLS-2 astronauts perform vestibular (human orientation system) experiments in flight. PI is an interactive system that provides data acquisition and analysis, experiment step rescheduling, and various other forms of reasoning to astronaut users. The hardware architecture of PI consists of a computer and an analog interface box. 'Off-the-shelf' equipment is employed in the system wherever possible in an effort to use widely available tools and then to add custom functionality and application codes to them. Other projects which can help prospective teams to learn more about portable computing in space are also discussed.

    17. Design and Fabrication of Multifunctional Portable Bi2Te3-Based Thermoelectric Camping Lamp

      Science.gov (United States)

      Zhou, Yi; Li, Gongping

      2018-05-01

      Camping lamps have been widely used in the lighting, power supply, and intelligent electronic equipment fields. However, applications of traditional chemical and solar camping lamps are largely limited by the physical size of the source and operating conditions. A new prototype multifunctional portable Bi2Te3-based thermoelectric camping lamp (TECL) has been designed and fabricated. Ten parallel light-emitting diodes were lit directly by a Bi2Te3-based thermoelectric generator (TEG). The highest short-circuit current of 0.38 A and open-circuit voltage of 4.2 V were obtained at temperature difference of 115 K. This TECL is attractive for use in multifunctional and extreme applications as it integrates a portable heat source, high-performance TEG, and power management unit.

    18. Evaluation of portable near-infrared spectroscopy for organic milk authentication.

      Science.gov (United States)

      Liu, Ningjing; Parra, Hector Aya; Pustjens, Annemieke; Hettinga, Kasper; Mongondry, Philippe; van Ruth, Saskia M

      2018-07-01

      Organic products are vulnerable to fraud due to their premium price. Analytical methodology helps to manage the risk of fraud and due to the miniaturization of equipment, tests may nowadays even be rapidly applied on-site. The current study aimed to evaluate portable near infrared spectroscopy (NIRS) in combination with chemometrics to distinguish organic milk from other types of milk, and compare its performance with benchtop NIRS and fatty acid profiling by gas chromatography. The sample set included 37 organic retail milks and 50 non-organic retail milks (of which 36 conventional and 14 green 'pasture' milks). Partial least squares discriminant analysis was performed to build classification models and kernel density estimation (KDE) functions were calculated to generate non-parametric distributions for samples' class probabilities. These distributions showed that portable NIRS was successful to distinguish organic milks from conventional milks, and so were benchtop NIRS and fatty acid profiling procedures. However, it was less successful when 'pasture' milks were considered too, since their patterns occasionally resembled those of the organic milk group. Fatty acid profiling was capable of distinguishing organic milks from both non-organic milks though, including the 'pasture' milks. This comparative study revealed that the classification performance of the portable NIRS for this application was similar to that of the benchtop NIRS. Copyright © 2018 Elsevier B.V. All rights reserved.

    19. Open manufacturing system using MMS service and object oriented manufacturing equipment

      International Nuclear Information System (INIS)

      Kim, Dong Hoon; Song, Jun Yeob; Kim, Sun Ho

      2007-01-01

      Manufacturing equipment should be integrated to construct CIM (Computer Integrated Manufacturing) environment, but several economical and technological difficulties may be arisen in case heterogeneous systems are integrated into each other. MMS (Manufacturing Message Specification) can be effective in such a case, but the problem is that MMS-related products are comparatively expensive and the existing manufacturing equipment mostly do not support MMS. This study was focused on developing a gateway suitable to a non-MMS-compatible CNC machine-tool, and on implementing OSI (Open System Interconnection) upper layer on TCP/IP. The development system was applied to a cell controller by means of heterogeneous equipment under CIM environment, and to evaluate interoperability and portability

    20. Production of NDA Working Reference Materials for the Capability Evaluation Project

      International Nuclear Information System (INIS)

      Noll, P.D. Jr.; Marshall, R.S.

      1998-01-01

      The production of Non Destructive Assay (NDA) Working Reference Materials (WRMs) that are traceable to nationally recognized standards was undertaken to support implementation of the Idaho National Engineering and Environmental Laboratory (INEEL) Nondestructive Waste Assay Capability Evaluation Project (CEP). The WRMs produced for the CEP project consist of Increased Am/Pu mass ration (IAP) and depleted Uranium (DU) WRMs. The CEP IAP/DU WRM set provides radioactive material standards for use in combination with 55 gallon drum waste matrix surrogates for the assessment of waste NDA assay system performance. The Production of WRMs is a meticulous process that is not without certain trials and tribulations. Problems may arise at any of the various stages of WRM production which include, but are not limited to; material characterization (physical, chemical, and isotopic), material blend parameters, personnel radiation exposure, gas generation phenomenon, traceability to national standards, encapsulation, statistical evaluation of the data, and others. Presented here is an overall description of the process by which the CEP WRMs were produced and certified as well as discussions pertaining to some of the problems encountered and how they were solved

    1. Roma Hukuku’nda Gemi, Han ve Ahır İşletenlerin Receptum Sorumluluğu

      OpenAIRE

      YEŞİLLER, Mehmet

      2013-01-01

      Çalışmamızda Roma Hukuku'nda gemi, han ve ahır işleten kimselerin sorumluluklarına ilişkin düzenlemeler ele alınmıştır. Roma?da özellikle gemi, han ve ahır işleten kimselerin yanlarında çalıştırdıkları kişilerin güvenilir olmamasından dolayı, taraflar arasındaki istisna sözleşmesinden kaynaklanan custodia sorumluluğuna ek olarak "actio de damno aut furto adversus nautas, caupones, stabularios ve receptum, nautae, cauponis, stabularii" sorumluluklarının düzenlendiği kaynaklardan...

    2. Menemen Ekolojik Koşullarında Lavanta (Lavandula spp.) Tür ve Çeşitlerinin Morfolojik, Verim ve Kalite Özelliklerinin Belirlenmesi

      OpenAIRE

      Karık, Ünal; Çiçek, Fatih; Çınar, Orçun

      2017-01-01

      Bu çalışma Menemen ekolojik koşullarında lavanta (Lavandula spp.) tür ve çeşitlerininmorfolojik, verim ve kalite özelliklerini belirlemek amacı ile 2015-2016yılları arasında yürütülmüştür. Çalışmada 2 farklı türe ait 8 farklı ticarilavanta çeşidi kullanılmıştır. 2 yıl sonucunda elde edilen veriler ışığında türve çeşitler arasında önemli farklılıklar bulunduğu tespit edilmiştir. Lavandintipi çeşitler, verim özellikleri açısından lavander tipi çeşitlerin önünegeçerken,  uçucu yağ oranı ve uçucu...

    3. Portable bench tester for piezo weigh-in-motion equipment : executive summary report.

      Science.gov (United States)

      2006-06-01

      The Ohio Department of Transportation's (ODOT) piezo weigh-in-motion (WIM) equipment must be tested for initial working operation and to insure continued correct operation. Currently, the only available method to verify the vehicle classification par...

    4. Utility of Monte Carlo Modelling for Holdup Measurements.

      Energy Technology Data Exchange (ETDEWEB)

      Belian, Anthony P.; Russo, P. A. (Phyllis A.); Weier, Dennis R. (Dennis Ray),

      2005-01-01

      Non-destructive assay (NDA) measurements performed to locate and quantify holdup in the Oak Ridge K25 enrichment cascade used neutron totals counting and low-resolution gamma-ray spectroscopy. This facility housed the gaseous diffusion process for enrichment of uranium, in the form of UF{sub 6} gas, from {approx} 20% to 93%. Inventory of {sup 235}U inventory in K-25 is all holdup. These buildings have been slated for decontaminatino and decommissioning. The NDA measurements establish the inventory quantities and will be used to assure criticality safety and meet criteria for waste analysis and transportation. The tendency to err on the side of conservatism for the sake of criticality safety in specifying total NDA uncertainty argues, in the interests of safety and costs, for obtaining the best possible value of uncertainty at the conservative confidence level for each item of process equipment. Variable deposit distribution is a complex systematic effect (i.e., determined by multiple independent variables) on the portable NDA results for very large and bulk converters that contributes greatly to total uncertainty for holdup in converters measured by gamma or neutron NDA methods. Because the magnitudes of complex systematic effects are difficult to estimate, computational tools are important for evaluating those that are large. Motivated by very large discrepancies between gamma and neutron measurements of high-mass converters with gamma results tending to dominate, the Monte Carlo code MCNP has been used to determine the systematic effects of deposit distribution on gamma and neutron results for {sup 235}U holdup mass in converters. This paper details the numerical methodology used to evaluate large systematic effects unique to each measurement type, validates the methodology by comparison with measurements, and discusses how modeling tools can supplement the calibration of instruments used for holdup measurements by providing realistic values at well

    5. Novel Wideband MIMO Antennas That Can Cover the Whole LTE Spectrum in Handsets and Portable Computers

      Directory of Open Access Journals (Sweden)

      Mohamed Sanad

      2014-01-01

      Full Text Available A dual resonant antenna configuration is developed for multistandard multifunction mobile handsets and portable computers. Only two wideband resonant antennas can cover most of the LTE spectrums in portable communication equipment. The bandwidth that can be covered by each antenna exceeds 70% without using any matching or tuning circuits, with efficiencies that reach 80%. Thus, a dual configuration of them is capable of covering up to 39 LTE (4G bands besides the existing 2G and 3G bands. 2×2 MIMO configurations have been also developed for the two wideband antennas with a maximum isolation and a minimum correlation coefficient between the primary and the diversity antennas.

    6. Development of portable phased array UT system for real-time flaw imaging

      International Nuclear Information System (INIS)

      Goto, M.

      1995-01-01

      Many functions and features of phased array UT technology must be useful for NDE in the industrial field. Some phased array UT systems have been developed for the inspection of nuclear pressure vessel and turbine components. However, phased array UT is still a special NDE technique and it has not been used widely in the past. The reasons of that are system size, cost, operator performance, equipment design and others. TOSHIBA has newly developed PC controlled portable phased array system to solve those problems. The portable phased array UT system is very compact and light but it is able to drive up to 32-channel linear array probe, to display real-time linear/sector B-scan, to display accumulated B-scan with an encoder and to display profile overlaid B-scan. The first applications were turbine component inspections for precise flaw investigation and flaw image data recording

    7. Dilbilim Kavramları Işığında Türkçe Öğretimi

      Directory of Open Access Journals (Sweden)

      Nilay Çağlayan DİLBER

      2017-12-01

      Full Text Available Anadili olarak Türkçe öğretiminde hem öğretmen yetiştirme hem de ilköğretim öğrencisi yetiştirme anlamında dilbilime ve dilbilimin elde ettiği verilere yeterince önem verilmemektedir. Oysa gelişmiş ülkelerdeki anadili eğitimine bakıldığında dilbilimden ve verilerinden sıkça yararlanılmaktadır. Yapılan çalışmada da bu eksikliği gidermek adına dilbilim kuramlarında yer alan kavramların anadili olarak Türkçe öğretiminde somut olarak nasıl yer alabileceğini ve zaten yer aldığını göstermek amaçlanmaktadır. Bu doğrultuda F. De Saussure ile bir bilim haline gelen ve 19. yy. itibariyle kuramlar üzerine yeni kuramlar üreterek dili farklı açılardan betimleyen Genel Dilbilim ders notları, Avrupa Yapısalcılığı, Amerikan Yapısalcılığı, Üretici Dönüşümsel Dilbilgisi, Edimbilim ve Sözceleme Kuramları’nda kullanılan ve bu kuramlarla ortaya çıkan bazı kavramların Türkçe öğretiminde kullanımı somut bir şekilde örneklendirilerek verilmiştir. Bu örneklerin Türkçe ders kitaplarına, etkinliklere, öğretim materyallerine yardımcı olacağı öngörülmektedir. Ayrıca çalışmanın Türkçe öğretmen adaylarının dilbilime daha somut bir şekilde yaklaşmasına ve dilbilimin dil öğretimindeki gerekliliğini anlamalarına yardımcı olacağı düşünülmektedir.

    8. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on Dihydrocapsiate

      DEFF Research Database (Denmark)

      Tetens, Inge

      Following a request from the European Commission, the EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) was asked to deliver a scientific opinion on the safety of a synthetic dihydrocapsiate (DHC) as a food ingredient in the context of Regulation (EC) No 258/97 taking into account...

    9. Developing an Affordable and Portable Control Systems Laboratory Kit with a Raspberry Pi

      OpenAIRE

      Rebecca M. Reck; R. S. Sreenivas

      2016-01-01

      Instructional laboratories are common in engineering programs. Instructional laboratories should evolve with technology and support the changes in higher education, like the increased popularity of online courses. In this study, an affordable and portable laboratory kit was designed to replace the expensive on-campus equipment for two control systems courses. The complete kit costs under $135 and weighs under 0.68 kilograms. It is comprised of off-the-shelf components (e.g., Raspberry Pi, DC ...

    10. Yeni Ürün Geliştirme Takımlarında Güven ve Takım Öğrenmesi

      Directory of Open Access Journals (Sweden)

      Volkan POLAT

      2018-01-01

      Full Text Available Farklı örgütsel seviyelerde güven ve öğrenme üzerine yapılan çalışmaların yanı sıra, güvenin takım bağlamında bilgi paylaşımı ve edinimi için önemli bir faktör olduğunu bildiren birtakım çalışmalar bulunmaktadır. Ancak bugüne kadar yeni ürün geliştirme takımlarında (new product development – NPD Takım Güveni ve Takım Öğrenmesi ilişkileri hakkında çok az tartışma yapılmıştır. Bu çalışma, Takım Güveninin, çeşitli takım faktörleri (Takım Üyesi Deneyimi, Takım İstikrarı ve Takım Otonomisi ve Takım Öğrenimi arasında arabuluculuk etkisi olup olmadığını incelemeyi amaçlamaktadır.

    11. Portable Instrumented Communication Library

      International Nuclear Information System (INIS)

      Geist, G.A.; Heath, M.T.; Peyton, B.W.; Worley, P.H.

      2001-01-01

      1 - Description of program or function: PICL is a subroutine library that can be used to develop parallel programs that are portable across several distributed-memory multi-processors. PICL provides a portable syntax for key communication primitives and related system calls. It also provides portable routines to perform certain widely- used, high-level communication operations, such as global broadcast and global summation. PICL provides execution tracing that can be used to monitor performance or to aid in debugging. 2 - Restrictions on the complexity of the problem: PICL is a compatibility library built on top of the native multiprocessor operating system and message passing primitives. Thus, the portability of PICL programs is not guaranteed, being a function of idiosyncrasies of the different platforms. Predictable differences are captured with standard error trapping routines. PICL is a research tool, not a production software system

    12. Portable bladder ultrasound: an evidence-based analysis.

      Science.gov (United States)

      2006-01-01

      cost-effective technology, because it avoids costs associated with catheterization equipment, saves nursing time, and reduces catheter-related complications and UTIs. The use of portable bladder ultrasound device will affect the patient directly in terms of health outcomes. Its use avoids the trauma related to the urinary tract that catheterization inflicts, and does not result in UTIs. In addition, patients prefer it, because it preserves dignity and reduces discomfort.

    13. CALCULATION OF ACOUSTIC EFFICIENCY OF PORTABLE ACOUSTIC SCREEN

      Directory of Open Access Journals (Sweden)

      Aleksandr Skvortsov

      2016-03-01

      Full Text Available The research of influence of life environment adverse factors on physical development and health of population is an actual problem of ecology. The aspects of the most actual problems of the modern world, namely environmental industrial noise pollution are considered in the article. Industrial facilities everywhere have noisy equipment. Noise is a significant factors of negative influenceon people and environment. Combined effects of noise and of other physical pollutions on people may cause amplification of their negative impact. If the noise pollution level from the object in a residential area exceeds the permissible levels (MPL, noise protection measures can be initiated. Today, the most common design decisions for noise protection are sound absorbing construction, noise screens and barriers, acousting housings, soundproff cabins. Many of them are popular, others are less known. The article deals with one of the most wide spread means of noise protection – a portable acoustic screen. The aim of the research is to determine the efficiency of portable acoustic screens. It is shown that the installation of such structures can reduce the average value of the sound level. The authors analyzed acoustic screens as device to reduce noise pollution. The authors offer a potable acoustic screen differing from the used easyness, mobility, minimum price and good sound protective properties. Effectiveness, a sound absorption coefficient and sound conductivity coefficient of a portable acoustic screen are evaluated. The descriptions of the algorithm calculations and the combination of technical solutions have practical originality. The results of the research demonstrate the advantages of the proposed solutions for reducing noise levels in the agro-industrial complex.

    14. Prototype Pompa Air Portable Tenaga Surya

      OpenAIRE

      Taufik, Mohammad

      2016-01-01

      Makalah ini menyajikan purwarupa pompa air portable tenaga surya. Sistem pompa air portable terdiri atas pompa air, panel surya, solar charge controller, battery, solar frame, tiang, dan box. Sistem dapat dirangkai, sehingga bersifat portable. Pompa air portable ini berguna untuk kolam, irigasi, dan penyediaan air bersih. Hasil optimasi memberikan spesifikasi pompa air berdaya 50 Watt dan tegangan 12 VDC, solar panel berdaya 50 Wp, battery berkapasitas 50 Ah dan tegangan 12 VDC, da...

    15. Development and assembly of equipment for non destructive assay system control using nuclear radiation

      International Nuclear Information System (INIS)

      Melo, Jose Altino Tupinamba

      2006-01-01

      Nondestructive Assay (NDA) is applied to machines and components quality tests. These elements would not have a good performance if they were conceived without concern about the mechanical project quality, used materials, manufacture processes and inspection and maintenance methodology. There are constant developments in high level of technology with the objective of guaranteeing the components quality and the good functioning of these machines, in the mechanics, naval, aeronautical, petrochemical and steel industry, energy and nuclear generation as well. The globalization in the industry lines is a fact, leading to an increase in the multinational projects and products. The following questions arise: how to assure the high quality of components and processes? How to optimize the test methods to assure that the materials do not have defects affecting the performance of the components? The answers to the questions above are found in the application of NDA. The complex materials analysis (inhomogeneous) using NDA requires a detailed study of the sensors response signal. In this work, a measure and control system of non destructive processes was developed, using a radioactive source with a defined energy in function of the material to be analyzed. This system involves: (a) Interface of input/output (I/O) (the Hardware) and (b) graphical Interface (Software). In the non destructive analysis, it is made the comparison of the signal proceeding from the sensor with a signal preset (Set Point) or analogical signal of reference (Base Line), which is adjusted in the I/O Interface. Analyzed the signal, the system will make the decision: (a) to reject or (b) to accept the analyzed material. The I/O Interface is implemented by electronic equipment with a MCS51. The purpose of this interface is to supply conditions to exchange information, using serial RS232, between the sensor and the microcomputer. The graphical Interface (software) is written in visual C++ language (author)

    16. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

      Science.gov (United States)

      McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

      2012-08-01

      Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

    17. Educational X-Ray Experiments and XRF Measurements with a Portable Setup Adapted for the Characterization of Cultural Heritage Objects

      Science.gov (United States)

      Sianoudis, I.; Drakaki, E.; Hein, A.

      2010-01-01

      It is common to modify valuable, sophisticated equipment, originally acquired for other purposes, to adapt it for the needs of educational experiments, with great didactic effectiveness. The present project concerns a setup developed from components of a portable system for energy dispersive x-ray fluorescence spectroscopy (EDXRF). Two educational…

    18. Software Engineering for Portability.

      Science.gov (United States)

      Stanchev, Ivan

      1990-01-01

      Discussion of the portability of educational software focuses on the software design and development process. Topics discussed include levels of portability; the user-computer dialog; software engineering principles; design techniques for student performance records; techniques of courseware programing; and suggestions for further research and…

    19. The equipment access software for a distributed UNIX-based accelerator control system

      International Nuclear Information System (INIS)

      Trofimov, Nikolai; Zelepoukine, Serguei; Zharkov, Eugeny; Charrue, Pierre; Gareyte, Claire; Poirier, Herve

      1994-01-01

      This paper presents a generic equipment access software package for a distributed control system using computers with UNIX or UNIX-like operating systems. The package consists of three main components, an application Equipment Access Library, Message Handler and Equipment Data Base. An application task, which may run in any computer in the network, sends requests to access equipment through Equipment Library calls. The basic request is in the form Equipment-Action-Data and is routed via a remote procedure call to the computer to which the given equipment is connected. In this computer the request is received by the Message Handler. According to the type of the equipment connection, the Message Handler either passes the request to the specific process software in the same computer or forwards it to a lower level network of equipment controllers using MIL1553B, GPIB, RS232 or BITBUS communication. The answer is then returned to the calling application. Descriptive information required for request routing and processing is stored in the real-time Equipment Data Base. The package has been written to be portable and is currently available on DEC Ultrix, LynxOS, HPUX, XENIX, OS-9 and Apollo domain. ((orig.))

    20. 48 CFR 1837.170 - Pension portability.

      Science.gov (United States)

      2010-10-01

      ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Pension portability. 1837... ADMINISTRATION SPECIAL CATEGORIES OF CONTRACTING SERVICE CONTRACTING Service Contracts-General 1837.170 Pension portability. (a) It is NASA's policy not to require pension portability in service contracts. However, pension...

    1. Sosyal Pazarlama Literatür İncelemesi: Prensipler ve Teknikler Kapsamında Ele Alınan Temel Konular (1971-2014)

      OpenAIRE

      Kitapcı, Olgun; Dörtyol, İbrahim Taylan; Gülmez, Mustafa

      2018-01-01

      SosyalPazarlama kavramının doğduğu tarihten günümüze yazılmış ve Web of Science (WOS)veri tabanında yayınlanmış makalelerin, Lee ve Kotler’in 2011 yılındayazdıkları kitapta yer alan sınıflandırma çerçevesinde yorumlanmasını amaçlayanbu çalışma sözkonusu alanda zaman içerisinde hakim olan araştırma eğilimlerini ortayakoymaktadır. Bu kapsamda, ilgili veri tabanında yer alan makalelerin tamamıtaranmış ve sınıflandırılmıştır. Makalelerin temel odakları sosyal pazarlamabağlamında ele alınan temel ...

    2. Monitoring equipment environment during nuclear plant operation at Salem and Hope Creek generating stations

      International Nuclear Information System (INIS)

      Blum, A.; Smith, R.J.

      1991-01-01

      Monitoring of environmental parameters has become a significant issue for operating nuclear power plants. While the long-term benefits of plant life extension programs are being pursued with comprehensive environmental monitoring programs, the potential effect of local hot spots at various plant locations needs to be evaluated for its effect on equipment degradation and shortening of equipment qualified life. A significant benefit can be experienced from temperature monitoring when a margin exists between the design versus actual operating temperature. This margin can be translated into longer equipment qualified life and significant reduction in maintenance activities. At PSE and G, the immediate need for monitoring environmental parameters is being accomplished via the use of a Logic Beach Bitlogger. The Bitlogger is a portable data loggings system consisting of a system base, input modules and a communication software package. Thermocouples are installed on selected electrical equipment and cables are run from the thermocouples to the input module of the Bitlogger. Temperature readings are taken at selected intervals, stored in memory, and downloaded periodically to a PC software program, i.e., Lotus. The data is formatted into tabular or graphical documents. Because of their versatility, Bitloggers are being used differently at the authors Nuclear facility. At the Salem Station (2 Units-4 loop Westinghouse PWR), a battery powered, fully portable, calibrated Bitlogger is located in an accessible area inside Containment where it monitors the temperature of various electrical equipment within the Pressurizer Enclosure. It is planned that close monitoring of the local hot spot temperatures in this area will allow them to adjust and reconcile the environmental qualification of the equipment

    3. Using operational equipment to read accident dosemeters.

      Science.gov (United States)

      Devine, R T; Vigil, M M; Martinez, W A

      2004-01-01

      Analysis of accident dosemeters usually involves the use of laboratory-based counting equipment. Gamma spectrometers are used for indium, copper and gold, and alpha-beta detectors for sulphur. This equipment is usually not easily transported due to the shielding required and the weight and delicacy of the counters. For intercomparison studies that require reading the dosemeters on site, a transportable system is required unless the site operating the study can count samples for all the participants. In the case of an actual accident these systems would have a difficulty in counting a large number of accident dosemeters. In an accident, personnel are usually subdivided according to their level of exposure. Those exposed to higher doses are treated immediately. An alternate system should be made available to handle the dosemeters worn by those personnel are likely to receive lower doses. Improvements in portable operational equipment for gamma and beta monitoring allow their use as spectrometers. Such a system was used for the SILENE intercomparison conducted at IRSN Valduc on 12 June and 19, 2002, and the preliminary results compared well with the other participants.

    4. PORTABLE ACOUSTIC MONITORING PACKAGE (PAMP)

      Energy Technology Data Exchange (ETDEWEB)

      John l. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Deepak Mehra

      2003-07-01

      The 1st generation acoustic monitoring package was designed to detect and analyze weak acoustic signals inside natural gas transmission lines. Besides a microphone it housed a three-inch diameter aerodynamic acoustic signal amplifier to maximize sensitivity to leak induced {Delta}p type signals. The theory and test results of this aerodynamic signal amplifier was described in the master's degree thesis of our Research Assistant Deepak Mehra who is about to graduate. To house such a large three-inch diameter sensor required the use of a steel 300-psi rated 4 inch weld neck flange, which itself weighed already 29 pounds. The completed 1st generation Acoustic Monitoring Package weighed almost 100 pounds. This was too cumbersome to mount in the field, on an access port at a pipeline shut-off valve. Therefore a 2nd generation and truly Portable Acoustic Monitor was built. It incorporated a fully self-contained {Delta}p type signal sensor, rated for line pressures up to 1000 psi with a base weight of only 6 pounds. This is the Rosemont Inc. Model 3051CD-Range 0, software driven sensor, which is believed to have industries best total performance. Its most sensitive unit was purchased with a {Delta}p range from 0 to 3 inch water. This resulted in the herein described 2nd generation: Portable Acoustic Monitoring Package (PAMP) for pipelines up to 1000 psi. Its 32-pound total weight includes an 18-volt battery. Together with a 3 pound laptop with its 4-channel data acquisition card, completes the equipment needed for field acoustic monitoring of natural gas transmission pipelines.

    5. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on bovine lactoferrin

      DEFF Research Database (Denmark)

      Tetens, Inge

      Following a request from the European Commission, the EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) was asked to carry out the additional assessment for ‘lactoferrin’ as a food ingredient in the context of Regulation (EC) No 258/97 taking into account the comments and objections...

    6. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on bovine lactoferrin

      DEFF Research Database (Denmark)

      Tetens, Inge

      Following a request from the European Commission, the EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) was asked to carry out the additional assessment of ‘lactoferrin’ as a food ingredient in the context of Regulation (EC) No 258/97 taking into account the comments and objections...

    7. Towards Application Portability on Blockchains

      OpenAIRE

      Shudo, Kazuyuki; Saito, Kenji

      2018-01-01

      We pose a fundamental problem of public blockchain, "incentive mismatch." It is an open problem, but application portability is a provisional solution to the problem. Portability is also a desirable property for an application on a private blockchain. It is not even clear to be able to define a common API for various blockchain middlewares, but it is possible to improve portability by reducing dependency on a blockchain. We present an example of such middleware designs that provide applicatio...

    8. Portable meter study of ionizing radiation Teletector in high rates of air kerma

      International Nuclear Information System (INIS)

      Damatto, Willian Behling; Potiens, Maria da Penha A.; Vivolo, Vitor

      2015-01-01

      A set of portable meters of ionizing radiation high rates of air kerma (teletectors) commonly used in emergencies in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analyst is parameters for the detectors behavior were established. Applied tests were: energy dependence and primarily overload with the new irradiation system. Thus it was possible to determine the most common characteristic found in these equipment (quality control programs) and new calibration criteria were established following international recommendations. (author)

    9. Toprakaltı termiti Heterotermes indicola (Wasmann) (Isoptera: Rhinotermitidae)’ya karşı indoxacarb ve chlorfenapyr’in laboratuvar koşullarında etkisi

      OpenAIRE

      MISBAH-UL-HAQ, Muhammad; KHAN, Imtiaz Ali; FARID, Abid; ULLAH, Misbah; GOUGE, Dawn H.; BAKER, Paul B.

      2016-01-01

      Indoxacarb ve chlorfenapyrin’in, Toprakaltı termiti, Heterotermes indicola (Wasmann)’da beslenme engelleyici ve bireyler arasında taşınma etkileri 2013-2014 yıllarında Gıda ve Tarım Nükleer Enstitüsü (NIFA) (Peshawar, Pakistan)’nde laboratuvar testleri ile değerlendirilmiştir. Test edilen kimyasal konsantrasyonları indoxacarb için 1-100 ppm (ağırlık/ağırlık) ve chlorfenapyrin 1 ile 7 ppm (ağırlık/ağırlık) arasında değişmiştir. Gözlemler indoxacarb’ın 50 ppm üzerindeki dozlarda hızlı ölüme seb...

    10. Atık Mermer Tozunun Parke Taşlarında Kullanılması

      OpenAIRE

      FİLİZ, Mümin; ÖZEL, Cengiz; SOYKAN, Oktar; EKİZ, Yunus

      2010-01-01

      Bu çalışmada iki farklı çimento tipi (CEM II/B-M (P-LL) 32.5 N ve CEM I 42.5 R) ve iki farklı su/çimento oranında (0.50 ve 0.55) hazırlanmış olan karışımlara mermer tozunun hacim oranınca agrega ile yer değiştirmesinin, mekanik ve fiziksel özelliklere etkisi araştırılmıştır. Elde edilen verilere göre mermer tozu atığının parke taşı imalatında kullanılabilirliği TS 2524 EN 1338 standardına göre değerlendirilmiştir. Elde edilen sonuçlara göre mermer tozu kullanımı ile betonların mekanik ve f...

    11. The characterization of an economic and portable LED-based photoacoustic imaging system to facilitate molecular imaging.

      Science.gov (United States)

      Hariri, Ali; Lemaster, Jeanne; Wang, Junxin; Jeevarathinam, AnanthaKrishnan S; Chao, Daniel L; Jokerst, Jesse V

      2018-03-01

      Photoacoustic imaging (PAI) is a non-invasive, high-resolution hybrid imaging modality that combines optical excitation and ultrasound detection. PAI can image endogenous chromophores (melanin, hemoglobin, etc.) and exogenous contrast agents in different medical applications. However, most current equipment uses sophisticated and complicated OPO lasers with tuning and stability features inconsistent with broad clinical deployment. As the number of applications of PAI in medicine increases, there is an urgent need to make the imaging equipment more compact, portable, and affordable. Here, portable light emitting diode - based photoacoustic imaging (PLED-PAI) was introduced and characterized in terms of system specifications, light source characterizations, photoacoustic spatial/temporal resolution, and penetration. The system uses two LED arrays attached to the sides of a conventional ultrasound transducer. The LED pulse repetition rate is tunable between 1 K Hz, 2 K Hz, 3 K Hz, and 4 K Hz. The axial resolution was 0.268 mm, and the lateral resolution was between 0.55 and 0.59 mm. The system could detect optical absorber (pencil lead) at a depth of 3.2 cm and the detection limits of indocyanine green (ICG) and methylene blue (MB) were 9 μM and 0.78 mM. In vivo imaging of labeled human mesenchymal stem cells was achieved to confirm compatibility with small animal imaging. The characterization we report here may have value to other groups evaluating commercially available photoacoustic imaging equipment.

    12. Portable kit for the assessment of gait parameters in daily telerehabilitation.

      Science.gov (United States)

      Giansanti, Daniele; Morelli, Sandra; Maccioni, Giovanni; Grigioni, Mauro

      2013-03-01

      When designing a complete process of daily telerehabilitation, it should be borne in mind that patients should be furnished with properly designed methodologies for executing specific motion tasks and the assessment of the relevant parameters. In general, such a process should comprehend three basic elements in both the hospital and the home: (a) instrumented walkways, (b) walking aids or supports, and (c) equipment for the assessment of parameters. The objective, with gait being the focus, of this study was thus to design a simple, portable kit-as an alternative to the complex and expensive instruments currently used-to be easily interfaced or integrated with the instrumented walkways and aids/supports both for self-monitoring while patients are exercising with their own aids and for clinical reporting. The proposed system is a portable kit that furnishes useful parameters with feedback to both the patient and the trainer/therapist. Capable of being integrated with the most common mechanical tools used in motion rehabilitation (handrail, scales, walkways, etc.), it constantly monitors and quantitatively assesses progress in rehabilitation care. It is composed of one step counter, photo-emitter detectors, one central unit for collecting and processing the telemetrically transmitted data, and a software interface. The system has been successfully validated on 16 subjects at the second level of the Tinetti test in a clinical application for both home and the hospital. The portable kit can be used with different rehabilitation tools and on varying ground rugosity. Advantages include (a) very low cost, when compared with optoelectronic solutions or other portable devices, (b) very high accuracy, also for subjects with imbalance problems, compared with other commercial solutions, and (c) integration (compatibility) with any rehabilitative tool.

    13. Highly effective portable beta spectrometer for precise depth selective electron Moessbauer spectroscopy

      International Nuclear Information System (INIS)

      Aldiyarov, N.U.; Kadyrzhanov, K.K.; Seytimbetov, A.M.; Zhdanov, V.S.

      2007-01-01

      Full text: More broad application of the nuclear-physical method of precise Depth Selective Electron Moessbauer Spectroscopy (DS EMS) is limited by insufficient accessibility of highly-effective beta spectrometers with acceptable resolution. It should be mentioned that the method DS EMS is realized at a combined installation that consists of a highly-effective beta spectrometer and a conventional portable nuclear gamma-resonance spectrometer. Yet few available beta spectrometers have sophisticated design and controlling; in most cases they are cumbersome. All the attempts to simplify beta spectrometers resulted in noticeable worsening of depth resolution for the DS EMS method making the measurements non precise. There is currently an obvious need in a highly-effective portable easily controlled beta spectrometer. While developing such portable beta spectrometer, it is more promising to use as basis a simpler spectrometer, which has ratio of sample size to spectrometer size of about five times. The paper presents an equal-arm version of a highly-effective portable beta spectrometer with transverse heterogeneous sector magnetic field that assures double focusing. The spectrometer is equipped with a large-area non-equipotential source (a sample under investigation) and a position-sensitive detector. This portable spectrometer meets all requirements for achievement of the DS EMS depth resolution close to the physical limit and demonstrates the following main characteristics: equilibrium orbit radius ρ 0 = 80 mm, instrumental energy resolution 0.6 % at solid angle 1 % of 4π steradian, area of non-equipotential source ∼ 80 mm 2 , registration by position-sensitive detector of ∼ 10 % of the energy interval. Highly-effective portable beta spectrometer assures obtaining Moessbauer data with depth resolution close to physical limit of the DS EMS method. So in measurements at conversion and Auger electrons with energies of about units of keV and above, the achieved

    14. Farklı Bölgelerin Üzümlerinden Üretilen Türk Şaraplarında Resveratrol Düzeyleri

      Directory of Open Access Journals (Sweden)

      Belkıs Adıgüzel Çaylak

      2015-02-01

      Full Text Available Resveratrol (3,5,4’ trihidroksistilben, fitoaleksin adı verilen bir polifenol çeşididir. Polifenoller üzümlerin kabuklarında, çekirdeklerinde ve saplarında bulunan maddelerdir. Fenolik bileşikler, özellikle flavanoller şarap alımıyla ilgili bilinen sağlık yararları açısından antioksidan özelliklere sahiptirler. Birçok çalışma, üzümlerde stres koşullarında bir savunma metaboliti olarak sentezlenen resveratrolün şarapta bulunduğunu göstermiştir. Şarap insanlarda kansere, iltihaplanmalara ve koroner kalp hastalıklarına karşı koruyucu özellikleri olduğu bilinen polifenol bileşikleri büyük oranda içermektedir. Hücre ve hayvanlarda yapılan çalışmalar, kırmızı şarabın, lösemi, deri, akciğer ve prostat kanserleri gibi pek çok kanser türünde koruyucu etkisi olduğunu göstermektedir. In-vivo çalışmalardan alınan son bilgiler, resveratrolün kanserin başlangıç, gelişme ve ilerleme safhalarında etkili bir ajan olabileceği hakkında bilgi vermektedir. Farklı ülkelerdeki şarapların içerdiği resveratrol miktarının belirlenmesi ile ilgili birçok araştırma olmasına rağmen, Türkiye’de çok az benzer çalışmalar bulunmaktadır. Bu çalışmada, Türkiye’nin farklı bölgelerinde yetişen üzümlerden üretilen şaraplar önemli şarap üreticilerinden temin edilmiş ve resveratrol miktarları Yüksek Performanslı Sıvı Kromatografisi cihazı kullanılarak belirlenmiştir. Elde edilen sonuçlar resveratrol konsantrasyonunun üzüm çeşidine ve bölgelere göre değişebileceğini göstermiştir.

    15. Portable bench tester for piezo weigh-in-motion equipment : final report, June 2006.

      Science.gov (United States)

      2006-06-01

      The Ohio Department of Transportation's (ODOT) piezo weigh-in-motion (WIM) equipment must be tested for initial working operation and to insure continued correct operation. Currently, the only available method to verify the vehicle classification par...

    16. Portable X-ray powder diffractometer for the analysis of art and archaeological materials

      Energy Technology Data Exchange (ETDEWEB)

      Nakai, Izumi; Abe, Yoshinari [Tokyo University of Science, Department of Applied Chemistry, Faculty of Science, Tokyo (Japan)

      2012-02-15

      Phase identification based on nondestructive analytical techniques using portable equipment is ideal for the analysis of art and archaeological objects. Portable(p)-XRF and p-Raman are very widely used for this purpose, yet p-XRD is relatively rare despite its importance for the analysis of crystalline materials. This paper overviews 6 types of p-XRD systems developed for analysis of art and archaeological materials. The characteristics of each system are compared. One of the p-XRD systems developed by the authors was brought to many museums as well as many archeological sites in Egypt and Syria to characterize the cultural heritage artifacts, e.g., amulet made of Egyptian blue, blue painted pottery, and Islamic pottery from Egypt, jade from China, variscite from Syria, a Japanese classic painting drawn by Korin Ogata, and oil paintings drawn by Taro Okamoto. Practical application data are shown to demonstrate the potential ability of the method for analysis of various art and archaeological materials. (orig.)

    17. Portable X-ray powder diffractometer for the analysis of art and archaeological materials

      Science.gov (United States)

      Nakai, Izumi; Abe, Yoshinari

      2012-02-01

      Phase identification based on nondestructive analytical techniques using portable equipment is ideal for the analysis of art and archaeological objects. Portable(p)-XRF and p-Raman are very widely used for this purpose, yet p-XRD is relatively rare despite its importance for the analysis of crystalline materials. This paper overviews 6 types of p-XRD systems developed for analysis of art and archaeological materials. The characteristics of each system are compared. One of the p-XRD systems developed by the authors was brought to many museums as well as many archeological sites in Egypt and Syria to characterize the cultural heritage artifacts, e.g., amulet made of Egyptian blue, blue painted pottery, and Islamic pottery from Egypt, jade from China, variscite from Syria, a Japanese classic painting drawn by Korin Ogata, and oil paintings drawn by Taro Okamoto. Practical application data are shown to demonstrate the potential ability of the method for analysis of various art and archaeological materials.

    18. Portable X-ray powder diffractometer for the analysis of art and archaeological materials

      International Nuclear Information System (INIS)

      Nakai, Izumi; Abe, Yoshinari

      2012-01-01

      Phase identification based on nondestructive analytical techniques using portable equipment is ideal for the analysis of art and archaeological objects. Portable(p)-XRF and p-Raman are very widely used for this purpose, yet p-XRD is relatively rare despite its importance for the analysis of crystalline materials. This paper overviews 6 types of p-XRD systems developed for analysis of art and archaeological materials. The characteristics of each system are compared. One of the p-XRD systems developed by the authors was brought to many museums as well as many archeological sites in Egypt and Syria to characterize the cultural heritage artifacts, e.g., amulet made of Egyptian blue, blue painted pottery, and Islamic pottery from Egypt, jade from China, variscite from Syria, a Japanese classic painting drawn by Korin Ogata, and oil paintings drawn by Taro Okamoto. Practical application data are shown to demonstrate the potential ability of the method for analysis of various art and archaeological materials. (orig.)

    19. Safeguards techniques and equipment. 2003 ed

      International Nuclear Information System (INIS)

      2003-01-01

      -destructive analysis (NDA) techniques, and compare their findings with the declared figures and the operator's records. The next level of verification has the aim of detecting whether a fraction of a declared amount is missing (partial defect) and may involve the weighing of items and measurements with NDA techniques such as neutron counting or gamma-ray spectrometry. For detecting bias defects, which would arise if small amounts of material were diverted over a protracted length of time, it is necessary to sample some of the items and to apply physical and chemical analysis techniques having the highest possible accuracy, typically less than one per cent. In order to apply these destructive analysis (DA) techniques, the IAEA requires access to laboratories which use such accurate techniques on a routine basis. Containment and surveillance (C/S) techniques, which are complementary to nuclear material accountancy techniques, are applied in order to maintain continuity of the knowledge gained through IAEA verification, by giving assurance that nuclear material follows predetermined routes, that the integrity of its containment remains unimpaired and that the material is accounted for at the correct measurement points. They also lead to savings in the safeguards inspection effort, e.g. by reducing the frequency of accountancy verification. A variety of C/S techniques are used, primarily optical surveillance and sealing. In remote monitoring, the unattended equipment transmits the data off-site. For unattended and remote monitoring, additional criteria must be met, including high reliability and authentication of the data source. Data communication costs have dropped dramatically in recent years. Data security is an important feature of unattended and remote monitoring systems. Environmental sampling, which allows detection of minute traces of nuclear material, was added to the IAEA's verification measures in the early 1990s as a powerful tool for detecting indications of undeclared

    20. Evaluation of portable Raman spectrometer with 1064 nm excitation for geological and forensic applications.

      Science.gov (United States)

      Vítek, Petr; Ali, Esam M A; Edwards, Howell G M; Jehlička, Jan; Cox, Rick; Page, Kristian

      2012-02-01

      The development of miniaturized Raman instrumentation is in demand for applications relevant to forensic, pharmaceutical and art analyses, as well as geosciences, and planetary exploration. In this study we report on evaluation of a portable dispersive Raman spectrometer equipped with 1064 nm laser excitation. Selected samples from geological, geobiological and forensic areas of interest have been studied from which the advantages, disadvantages and the analytical potential of the instrument are assessed based on a comparison with bench instrumentation and other portable Raman spectrometers using 785 nm excitation. It is demonstrated that the instrument operating with 1064 nm excitation has potential for expanding the number and types of samples that can be measured by miniaturized Raman spectroscopy without interfering fluorescence background emission. It includes inorganic and organic minerals, biomolecules within living lichen and endolithic cyanobacteria as well as drugs of abuse and explosives. Copyright © 2011 Elsevier B.V. All rights reserved.

    1. A Trusted Portable Computing Device

      Science.gov (United States)

      Ming-wei, Fang; Jun-jun, Wu; Peng-fei, Yu; Xin-fang, Zhang

      A trusted portable computing device and its security mechanism were presented to solve the security issues, such as the attack of virus and Trojan horse, the lost and stolen of storage device, in mobile office. It used smart card to build a trusted portable security base, virtualization to create a secure virtual execution environment, two-factor authentication mechanism to identify legitimate users, and dynamic encryption to protect data privacy. The security environment described in this paper is characteristic of portability, security and reliability. It can meet the security requirement of mobile office.

    2. Portable gamma-ray spectrometers and spectrometry systems

      International Nuclear Information System (INIS)

      Shebell, P.

      1999-01-01

      The current state-of-the-art in portable gamma-ray spectrometers and portable spectrometry systems is discussed. A comparison of detector performance and features of commercially available systems are summarised. Finally, several applications of portable systems are described. (author)

    3. Portable modular detection system

      Science.gov (United States)

      Brennan, James S [Rodeo, CA; Singh, Anup [Danville, CA; Throckmorton, Daniel J [Tracy, CA; Stamps, James F [Livermore, CA

      2009-10-13

      Disclosed herein are portable and modular detection devices and systems for detecting electromagnetic radiation, such as fluorescence, from an analyte which comprises at least one optical element removably attached to at least one alignment rail. Also disclosed are modular detection devices and systems having an integrated lock-in amplifier and spatial filter and assay methods using the portable and modular detection devices.

    4. MINAC, portable high energy radiographic inspection system

      International Nuclear Information System (INIS)

      Lapides, M.E.; Schonberg, R.

      1985-01-01

      MINAC, a portable, high energy radiographic source (1) was recognized as a desired inspection device for nuclear generation plants during EPRI-sponsored studies of the late 1970s and rapidly transitioned from proof-of-principle (1978-1980) to field-proven hardware (1981-present date). The equipment has completed its second generation of configuration development (SHRINKAC), that has recently been used in the field for detection of pipe cracks. Important auxiliaries for image data processing and real-time, thick section radiography have been demonstrated in both laboratory and field situations. Finally, a 6 MeV accelerator alternate is in bench test. These significant developments have, and are expected to continue to upgrade the utility of radiographic inspection in power plant practice. This paper describes the development and experience with this modular system during the last three years

    5. In situ measurement of heavy metals in water using portable EDXRF and APDC pre-concentration methodology

      International Nuclear Information System (INIS)

      Melquiades, Fabio L.; Parreira, Paulo S.; Appoloni, Carlos R.; Silva, Wislley D.; Lopes, Fabio

      2007-01-01

      With the objective of identify and quantify metals in water and obtain results in the sampling place, Energy Dispersive X-Ray Fluorescence (EDXRF) methodology with a portable equipment was employed. In this work are presented metal concentration results for water samples from two points of Londrina city. The analysis were in situ, measuring in natura water and samples pre-concentrated in membranes. The work consisted on the use of a portable X-ray tube to excite the samples and a Si-Pin detector with the standard data acquisition electronics to register the spectra. The samples were filtered in membranes for suspended particulate matter retention. After this APDC precipitation methodology was applied for sample pre-concentration with posterior filtering in membranes. For in natura samples were found concentrations of total iron in Capivara River 254 ± 30 mg L -1 and at Igapo Lake 63 ± 9 mg L -1 . For membrane measurements, the results for particulate suspended matter at Capivara River were, in mg L -1 : 31.0 ± 2.5 (Fe), 0.17 ± 0.03 (Cu) and 0.93 ± 0.08 (Pb) and for dissolved iron was 0.038 ± 0.004. For Igapo Lake just Fe was quantified: 1.66 ±0.19 mg L -1 for particulate suspended iron and 0.79 ± 0.11 mg L -1 for dissolved iron. In 4 h of work at field it was possible to filter 14 membranes and measure around 16 samples. The performance of the equipment was very good and the results are satisfactory for in situ measurements employing a portable instrument. (author)

    6. Portable nucleic acid thermocyclers.

      Science.gov (United States)

      Almassian, David R; Cockrell, Lisa M; Nelson, William M

      2013-11-21

      A nucleic acid thermal cycler is considered to be portable if it is under ten pounds, easily carried by one individual, and battery powered. Nucleic acid amplification includes both polymerase chain reaction (e.g. PCR, RT-PCR) and isothermal amplification (e.g. RPA, HDA, LAMP, NASBA, RCA, ICAN, SMART, SDA). There are valuable applications for portable nucleic acid thermocyclers in fields that include clinical diagnostics, biothreat detection, and veterinary testing. A system that is portable allows for the distributed detection of targets at the point of care and a reduction of the time from sample to answer. The designer of a portable nucleic acid thermocycler must carefully consider both thermal control and the detection of amplification. In addition to thermal control and detection, the designer may consider the integration of a sample preparation subsystem with the nucleic acid thermocycler. There are a variety of technologies that can achieve accurate thermal control and the detection of nucleic acid amplification. Important evaluation criteria for each technology include maturity, power requirements, cost, sensitivity, speed, and manufacturability. Ultimately the needs of a particular market will lead to user requirements that drive the decision between available technologies.

    7. Portable linear accelerator development. Final report

      International Nuclear Information System (INIS)

      Schonberg, R.G.

      1983-01-01

      The final report on Project RP 822-6 describes the MINAC 3 development from the recognition of need for a lightweight, portable high-energy device to the successful completion and field use of the MINAC. MINAC, which represents a substantial improvement in field radiographic capability and in technology, rapidly transitioned from proof-of-principle (1978 to 1980) to field-proven product (1980 to 1981). As a result, the decision has been made to develop this report as a users guide as well as a historic record of design, development, and testing program. The first section of this report has the following principal objectives: to describe the existing MINAC equipment capabilities and achievable modifications; to provide applications information for prospective users; and to provide technical information on high-energy radiography useful for familiarization and planning. The users guide section is followed by sections which describe the design basis, development, and application history of MINAC through the course of EPRI RP822 research projects 1 to 5, inclusively

    8. Meyve Konservelerinde ve Sularında Bozulmalara Neden Olan Küf Mantarları

      Directory of Open Access Journals (Sweden)

      Jale Acar

      2015-02-01

      Full Text Available Bakteriler, meyve suları ve konservelerinin bozulmalarında pek önemli rol oynamadıkları halde mayalar ve özellikle küf mantarları bu bozulmalarda önemli bir yer alırlar. Çeşitli mikroorganizmaların gelişme isteklerinin farklı olması buna neden olmaktadır. Küf mantarlarının büyük bir kısmı ancak aerob koşullar altında gelişebilirler. Bu gelişme en fazla yüzeydedir. Konserve kutularının hermetikli olan kapatılması ve tepe boşluğunda çok az oksijen bulunması yüzeyde küf mantarlarının gelişmesini önlemekle beraber Byssochlamys cinsinden küf mantarları anaerob koşullar altında fazla olmasa bile gelişebilmektedirler. Küf mantarları bakterilere oranla az miktarda suya gereksinim duyarlar. Aspergillus glaucus ve birçok Penicillium türleri kserofil olup aktif suyun çok düşük olduğu 0.70-0.75 gelişebilmelerine karşın bu değer bakterilerde 0.90-0.98 arasındadır. Çok az miktardaki su örneğin, yüzeydeki kondense su pastörizasyonda öldürülemeyen veya sonradan herhangi bir şekilde reçel kabına giren küflerin gelişmesine yardımcı olabilir. Sonradan bulaşma özellikle evlerde yapılan ve soğuduktan sonra kapağı kapatılan, özellikle reçel kabı selofan kağıdı ile kapatılıyorsa, sık sık görülmektedir. Diğer taraftan kaplar reçel soğutulmadan kapatılacak olursa suyun kondense olma miktarı artmaktadır.

    9. Ruminations On NDA Measurement Uncertainty Compared TO DA Uncertainty

      International Nuclear Information System (INIS)

      Salaymeh, S.; Ashley, W.; Jeffcoat, R.

      2010-01-01

      It is difficult to overestimate the importance that physical measurements performed with nondestructive assay instruments play throughout the nuclear fuel cycle. They underpin decision making in many areas and support: criticality safety, radiation protection, process control, safeguards, facility compliance, and waste measurements. No physical measurement is complete or indeed meaningful, without a defensible and appropriate accompanying statement of uncertainties and how they combine to define the confidence in the results. The uncertainty budget should also be broken down in sufficient detail suitable for subsequent uses to which the nondestructive assay (NDA) results will be applied. Creating an uncertainty budget and estimating the total measurement uncertainty can often be an involved process, especially for non routine situations. This is because data interpretation often involves complex algorithms and logic combined in a highly intertwined way. The methods often call on a multitude of input data subject to human oversight. These characteristics can be confusing and pose a barrier to developing and understanding between experts and data consumers. ASTM subcommittee C26-10 recognized this problem in the context of how to summarize and express precision and bias performance across the range of standards and guides it maintains. In order to create a unified approach consistent with modern practice and embracing the continuous improvement philosophy a consensus arose to prepare a procedure covering the estimation and reporting of uncertainties in non destructive assay of nuclear materials. This paper outlines the needs analysis, objectives and on-going development efforts. In addition to emphasizing some of the unique challenges and opportunities facing the NDA community we hope this article will encourage dialog and sharing of best practice and furthermore motivate developers to revisit the treatment of measurement uncertainty.

    10. RUMINATIONS ON NDA MEASUREMENT UNCERTAINTY COMPARED TO DA UNCERTAINTY

      Energy Technology Data Exchange (ETDEWEB)

      Salaymeh, S.; Ashley, W.; Jeffcoat, R.

      2010-06-17

      It is difficult to overestimate the importance that physical measurements performed with nondestructive assay instruments play throughout the nuclear fuel cycle. They underpin decision making in many areas and support: criticality safety, radiation protection, process control, safeguards, facility compliance, and waste measurements. No physical measurement is complete or indeed meaningful, without a defensible and appropriate accompanying statement of uncertainties and how they combine to define the confidence in the results. The uncertainty budget should also be broken down in sufficient detail suitable for subsequent uses to which the nondestructive assay (NDA) results will be applied. Creating an uncertainty budget and estimating the total measurement uncertainty can often be an involved process, especially for non routine situations. This is because data interpretation often involves complex algorithms and logic combined in a highly intertwined way. The methods often call on a multitude of input data subject to human oversight. These characteristics can be confusing and pose a barrier to developing and understanding between experts and data consumers. ASTM subcommittee C26-10 recognized this problem in the context of how to summarize and express precision and bias performance across the range of standards and guides it maintains. In order to create a unified approach consistent with modern practice and embracing the continuous improvement philosophy a consensus arose to prepare a procedure covering the estimation and reporting of uncertainties in non destructive assay of nuclear materials. This paper outlines the needs analysis, objectives and on-going development efforts. In addition to emphasizing some of the unique challenges and opportunities facing the NDA community we hope this article will encourage dialog and sharing of best practice and furthermore motivate developers to revisit the treatment of measurement uncertainty.

    11. Timing criteria for supplemental BWR emergency response equipment

      International Nuclear Information System (INIS)

      Bickel, John H.

      2015-01-01

      The Great Tohuku Earthquake and subsequent Tsunami represented a double failure event which destroyed offsite power connections to Fukushima-Daiichi site and then destroyed on-site electrical systems needed to run decay heat removal systems. The accident could have been mitigated had there been supplemental portable battery chargers, supplemental pumps, and in-place piping connections to provide alternate decay heat removal. In response to this event in the USA, two national response centers, one in Memphis, Tennessee, and another in Phoenix, Arizona, will begin operation. They will be able to dispatch supplemental emergency response equipment to any nuclear plant in the U.S. within 24 hours. In order to define requirements for supplemental nuclear power plant emergency response equipment maintained onsite vs. in a regional support center it is necessary to confirm: (a) the earliest time such equipment might be needed depending on the specific scenario, (b) the nominal time to move the equipment from a storage location either on-site or within the region of a nuclear power plant, and (c) the time required to connect in the supplemental equipment to use it. This paper describes an evaluation process for a BWR-4 with a Mark I Containment starting with: (a) severe accident simulation to define best estimate times available for recovery based on the specific scenario, (b) identify the key supplemental response equipment needed at specific times to accomplish recovery of key safety functions, and (c) evaluate what types of equipment should be warehoused on-site vs. in regional response centers. (authors)

    12. EE's gamma-ray spectrometer answers the national need for a portable, rugged, self-contained radioisotope analyzer

      International Nuclear Information System (INIS)

      McGibbon, A.L.

      1976-01-01

      Growing national interest in public safety has produced a sudden need for a type of radiation-monitoring equipment that doesn't exist anywhere commercially. An easily portable, very rugged, and completely self-contained instrument is required that can be set up quickly and virtually anywhere to detect and identify radioactive isotopes. The Electronics Engineering Department has responded to this need by designing and developing the first equipment that can fulfill all these requirements. This instrument, a 1024-channel gamma-ray spectrometer, has already gone into limited production to provide health physicists at LLL and other Energy Research and Development Administration (ERDA) laboratories with an effective tool for monitoring possible sources of radioactivity

    13. 29 CFR 1915.132 - Portable electric tools.

      Science.gov (United States)

      2010-07-01

      ... 29 Labor 7 2010-07-01 2010-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...

    14. 21 CFR 868.5440 - Portable oxygen generator.

      Science.gov (United States)

      2010-04-01

      ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...

    15. Understanding portable generators

      Energy Technology Data Exchange (ETDEWEB)

      Hills, A.; Hawkins, B. [Guelph Univ., ON (Canada); Clarke, S. [Ontario Ministry of Agriculture, Food and Rural Affairs, Toronto, ON (Canada)

      2000-06-01

      This factsheet is intended to help consumers select a small portable generator for emergency electrical needs. Interest in standby generators has been heightened ever since the prolonged power outage in Eastern Ontario and Southwestern Quebec during the 1998 ice storm and the concern over Y2K related outages. Farmers, in particular, have been reassessing their need for emergency electrical power supply. This document presents some of the factors that should be considered when purchasing and operating a portable generator in the 3 to 12 kW size. It provides a detailed review of power quality and describes the use of tractor-driven power-take-off generators of 15 kW and larger. Several manufacturers make portable generators in many sizes with a whole range of features. This document includes a table depicting generator Feature/Benefit analysis to help consumers understand the differences between features and benefits. A second table provides a check list for generator feature/benefits. Specific details for the operations of various generators are available from manufacturers, distributors and electrical contractors. 2 tabs., 1 fig.

    16. Tarihsel süreç içinde peyzaj tasarım ve uygulama çalışmalarında yapı malzemelerinin kullanımının irdelenmesi

      OpenAIRE

      Shakouri, Nasim

      2010-01-01

      Peyzaj, sayısız materyallerden oluşan görsel bir bütünlük olarak tanımlanmaktadır. Bu materyaller zaman içindeki değişimlerle, peyzaj tipi ve karakterini belirlemektedir. Peyzaj mimarlığında kullanılan materyaller, canlı ve cansız materyaller olarak ayrıca tanımlanmaktadır. Cansız materyaller kavramı içinde, peyzaj mimarlığında kullanılan yapısal öğelerin oluşturmasında önemli rol oynayan yapı malzemeleri de yer almaktadır. Peyzaj mimarlığında kullanılan yapısal malzemelerin özellikl...

    17. 30 CFR 47.44 - Temporary, portable containers.

      Science.gov (United States)

      2010-07-01

      ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Temporary, portable containers. 47.44 Section... TRAINING HAZARD COMMUNICATION (HazCom) Container Labels and Other Forms of Warning § 47.44 Temporary, portable containers. (a) The operator does not have to label a temporary, portable container if he or she...

    18. 48 CFR 1852.237-71 - Pension portability.

      Science.gov (United States)

      2010-10-01

      ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Pension portability. 1852... 1852.237-71 Pension portability. As prescribed at 1837.110-70(b), insert the following clause: Pension Portability (JAN 1997) (a) In order for pension costs attributable to employees assigned to this contract to...

    19. Lactococcus lactis Subsp. Lactis Suşlarında Yüksek Sıklıkta Konjugal Transfer Sistemlerinin Analizi

      Directory of Open Access Journals (Sweden)

      Çağla Tükel

      2015-02-01

      Full Text Available Bu çalışmada L. lactis subsp. lactis suşlarında laktoz fermentasyonu özelliğini kodlayan altı farklı plazmidin yüksek sıklıkta konjugal aktarım yeteneği araştırıldı. Bu plazmidlerin konjugal transfer sıklıkları; iki seks faktörünün interaksiyonuna bağlı olarak (Clu ve Agg, Clu-/Agg-, Agg+ x Clu-/Agg+, Agg- ya da Clu+/Agg- x Clu-/Agg- konjugasyon eşleri için 1.5x10-5–1.0x10-7 ve Clu+/Agg- x Clu-/Agg+ konjugasyon eşleri için 7.1x10-2-2.7x10-3 oranlarında değişim gösterdi. Laktoz plazmidlerinin stabiliteleri ise; doğal suşlarda %82-96, MG1390 alıcı suşu için tanımlanan konjugantlarda %77-98 ve MCL8060 alıcı suşu için tanımlanan konjugantlarda ise %44-67 arasında saptandı.

    20. Domates Pulpu ve Salçasında Viskozite (Konsistens ve Renk Üzerine Proses Koşullarının Etkisi

      Directory of Open Access Journals (Sweden)

      Aziz Ekşi

      2015-02-01

      Full Text Available Kıvam ve renk, domates pulpu ve salçada kaliteyi belirleyen ve ticarette üzerinde en çok durulan iki önemli etkendir. Domates salçasında renk ve kıvam ile hammaddenin durumu arasında yakın bir ilişki bulunduğu bilinmektedir. Ancak her iki kalite öğesini ve özellikle kıvamı, hammadde olduğu kadar, proses koşulları da etkilemektedir.

    1. 29 CFR 1917.119 - Portable ladders.

      Science.gov (United States)

      2010-07-01

      ... Requirements for Portable Reinforced Plastic Ladders (d) Standards for job-made portable ladders. Job-made... usage. (1) Ladders made by fastening rungs or devices across a single rail are prohibited. (2) Ladders...

    2. İçme ve sulama sularında bor kirliliği ve bor giderme yöntemleri

      Directory of Open Access Journals (Sweden)

      Meltem Bilici Başkan

      2014-03-01

      Full Text Available Periyodik cetvelin 3A grubunda yer alan bor yüksek iyonlaşma potansiyeline sahip olması nedeniyle yarı metal olarak kabul edilir. Yerkabuğundaki ortalama bor konsantrasyonu 10 mg/kg'dır. Bor doğada Ca, Na ve Mg'un tuzları şeklinde bulunur. Yüksek konsantrasyonlarda ve ekonomik boyutlardaki bor yatakları; borun oksijen ile bağlanmış bileşikleri şeklinde daha çok Türkiye ve ABD'nin kurak, volkanik ve hidrotermal aktivitesi olan bölgelerinde bulunmaktadır. Bor, bitkiler için gerekli bir mikro besin elementi olmanın yanı sıra, gerekli tüm besin elementleri içerisinde, eksiklik belirtilerine neden olan miktarı ile toksik etki yapan miktarı, birbirine çok yakın olan tek elementtir. Bor su ortamında genellikle borik asit ve kısmen de borat tuzları formlarında bulunmaktadır. Pek çok endüstride kullanım alanı bulan bor bileşiklerinin endüstriyel gelişmelere bağlı olarak yüzeysel sularda bulunan konsantrasyonu artış göstermektedir. Yüzeysel sularda bulunan bor aynı zamanda evsel atıksulardan da kaynaklanmaktadır. Türkiye'de içme ve sulama sularını en çok kirleten toksik elementlerin başında bor gelmektedir. Bu nedenle bor giderimi hem insan sağlığı açısından hem de sağlıklı tarım ürünü yetiştirilebilmesi açısından oldukça önemlidir. Sulardan bor giderimi için uygulanan temel yöntemler arasında iyon değişimi, ultrafiltrasyon, ters osmoz ve adsorbsiyon gelmektedir.

    3. Isotope-equipped electrostatic field meter, type RMEL-70, manufactured by the ''Polon'' Works, Cracow

      Energy Technology Data Exchange (ETDEWEB)

      Szumska, B; Tomaszewski, W

      1973-01-01

      The authors describe the operating principle, design features and use of an isotope-equipped meter, type RMEL-70, for measuring electrostatic field intensity and surface charge density. Being a light, portable instrument, it permits to determine the degree of electrification of dielectrics, evaluate the hazard of charge being collected, and to check the effectiveness of deionizers installed in industrial plants.

    4. Fast critical assembly safeguards: NDA methods for highly enriched uranium. Summary report, October 1978-September 1979

      International Nuclear Information System (INIS)

      Bellinger, F.O.; Winslow, G.H.

      1980-12-01

      Nondestructive assay (NDA) methods, principally passive gamma measurements and active neutron interrogation, have been studied for their safeguards effectiveness and programmatic impact as tools for making inventories of highly enriched uranium fast critical assembly fuel plates. It was concluded that no NDA method is the sole answer to the safeguards problem, that each of those emphasized here has its place in an integrated safeguards system, and that each has minimum facility impact. It was found that the 185-keV area, as determined with a NaI detector, was independent of highly-enriched uranium (HEU) plate irradiation history, though the random neutron driver methods used here did not permit accurate assay of irradiated plates. Containment procedures most effective for accurate assaying were considered, and a particular geometry is recommended for active interrogation by a random driver. A model, pertinent to that geometry, which relates the effects of multiplication and self-absorption, is described. Probabilities of failing to detect that plates are missing are examined

    5. Supporting design information for portable exhauster installation at tanks S-109, SX-102/103, BY-105/106, S-101/102, and S-107

      International Nuclear Information System (INIS)

      Keller, C.M.

      1997-01-01

      This document provides supporting calculations and equipment dedication plans for portable exhausters and ductwork installed on tanks S-109, SX-102/103, BY-105/106, S-101/102, and S-107. The exhausters will ventilate the tanks during saltwell pumping to prevent the potential accumulation of flammable gases

    6. Portable nucleonics instrument design: The PortaCAT example

      International Nuclear Information System (INIS)

      Wallace, G.; Pohl, P.; Hutchinson, E.

      2000-01-01

      Portable nucleonic gauges prototypes are designed and manufactured in New Zealand for niche applications. Considerable development in hardware and software provide new opportunity in design of relatively low cost portable nucleonic gauges. In this paper are illustrated principles, and specific factors to be consider when designing portable nucleonic instrumentation, using an example called PortaCAT, which is a portable computed tomography scanner designed for imaging wooden power poles. (author)

    7. Portable Tablets in Science Museum Learning

      DEFF Research Database (Denmark)

      Gronemann, Sigurd Trolle

      2016-01-01

      Despite the increasing use of portable tablets in learning, their impact has received little attention in research. In five different projects, this media-ethnographic and design-based analysis of the use of portable tablets as a learning resource in science museums investigates how young people...... is identified. It is argued that, paradoxically, museums’ decisions to innovate by introducing new technologies, such as portable tablets, and new pedagogies to support them conflict with many young people’s traditional ideas of museums and learning. The assessment of the implications of museums’ integration...... of portable tablets indicates that in making pedagogical transformations to accommodate new technologies, museums risk opposing didactic intention if pedagogies do not sufficiently attend to young learners’ systemic expectations to learning and to their expectations to the digital experience influenced...

    8. Safeguards equipment of the future: Integrated monitoring systems and remote monitoring

      International Nuclear Information System (INIS)

      Sonnier, C.S.; Johnson, C.S.

      1994-01-01

      From the beginning, equipment to support IAEA Safeguards could be characterized as that which is used to measure nuclear material, Destructive Assay (DA) and Non Destructive Assay (NDA), and that which is used to provide continuity of knowledge between inspection intervals, Containment ampersand Surveillance (C/S). C/S equipment has often been thought of as Cameras and Seals, with a limited number of monitors being employed as they became available. In recent years, technology has advanced at an extremely rapid rate, and continues to do so. The traditional film cameras are being replaced by video equipment, and fiber optic and electronic seals have come into rather widespread use. Perhaps the most interesting aspect of this evolution, and that which indicates the wave of the future without much question, is the integration of video surveillance and electronic seals with a variety of monitors. This is demonstrated by safeguards systems which are installed in several nuclear facilities in France, Germany, Japan, the UK, the USA, and elsewhere. The terminology of Integrated Monitoring Systems (IMS) has emerged, with the employment of network technology capable of interconnecting all desired elements in a very flexible manner. Also, the technology for transmission of a wide variety of information to off-site locations, termed Remote Monitoring, is in widespread industrial use, requiring very little adaptation for safeguards use. This paper examines the future of the Integrated Monitoring Systems and Remote Monitoring in International Safeguards, including technical and other related factors

    9. Derin suda dairesel silindir arkasında meydana gelen akış yapısının örgü teller ile kontrol edilmesi

      Directory of Open Access Journals (Sweden)

      Burcu Oğuz

      2016-08-01

      Full Text Available Bu çalışmada amaç derin su içerisine yerleştirilen silindire (bacalar, yüksek binalar vb. ve arkasındaki bir cisme veya cisimlere girdap kopması sonucu etki eden daimi olmayan yüklerin etkisinin ve şiddetinin azaltılması ve optimum değerlerin (tel kalınlığı ve geçirgenlik oranı, β belirlenmesidir. Bu amaçla çapı D=50 mm olan dairesel silindir etrafına sarılan farklı kalınlık ve geçirgenlik oranına sahip örgü tellerin etkisi Re_D=5000 değerinde araştırılmıştır. Geçirgenlik oranları β=0.5-0.8 aralığında 0.1 artımlarla dört farklı değerdedir. Silindir üzerine sarılmış tellerin kalınlıkları b=1 mm, 2 mm, 3mm ve 4mm’dir. Silindir arkasında meydana gelen akış yapısı, silindir etrafına sarılan örgü tellerle kontrol edilmeye çalışılmıştır. Deneyler PIV (parçacık görüntülemeli hız ölçme tekniği kullanılarak yürütülmüştür. Tüm geçirgenlik oranlarında, Türbülans Kinetik Enerji (TKE ve Reynolds kayma gerilmesi değerleri b=1 mm ve 2 mm tel kalınlıklarında, örgüsüz silindirin değeri ile kıyaslandığında artmakta fakat b=3 mm ve 4 mm kalınlıklarında azalmaktadır. Geçirgenlik oranı, β=0.6 değerinde ve tel kalınlığı b=4 mm durumunda TKE ve Reynolds kayma gerilmesi değerleri, örgü tellerinin silindir arkasında meydana gelen akışı kontrol ettiğini göstermektedir. Frekans değerlerinin sonuçları da örgü tellerin, silindir arkasındaki akışı, geçirgenlik oranı β=0.6 ve b=4 mm tel kalınlığında en iyi kontrolü sağladığını net bir şekilde açıklamaktadır

    10. 49 CFR 172.326 - Portable tanks.

      Science.gov (United States)

      2010-10-01

      ... petroleum gas (LPG) that is unodorized as authorized in § 173.315(b)(1) unless it is legibly marked NON... the portable tank are not visible. (d) NON-ODORIZED marking on portable tanks containing LPG. After...

    11. İstanbul’da 1999 Yılında Sonuçlanmış Boşanma Davalarında Boşanma Nedenlerinin Değerlendirilmesi

      Directory of Open Access Journals (Sweden)

      Halim Dişsever

      2000-12-01

      Full Text Available Bu çalışmada İstanbul'da 1999 yılında sonuçlanmış boşanma davalarından rastlantısal örnekleme yöntemiyle seçilen 3060 boşanma olgusu incelenerek, boşanma nedenleri ve diğer değişkenler arasındaki ilişkilerin değerlendirilmesi amaçlanmıştır İncelenen ve davası sonuçlanmış toplam 3060 boşanma davasının %67.1’si kailin (2053, %32.9'u (1007 erkek taralından açılmıştır, boşanma nedenlerine göre dağılım incelendiğinde ilk sırayı şiddetli geçimsizlik, ikinci sırayı alkol kötüye kullanımı, üçüncü sırayı cana kast ve pek fena muamele. i sırayı ise terk boşanma nedeninin aldığı görülmektedir. Boşanan çiftlerin %41.6 sı (1272 çift çocuksuz olup. %40.4 ü (12.36 çift evliliklerinin ilk 5 yılı içinde boşanmışlardır. Çocukların çoğunun yaşları küçük olduğundan velayetlerin annelere verilme oranı daha yüksektir. Olguların %7.6’smıla (233 çift eşlerden birinin, %28.2’ sinde (864 çift her ikisinin İstanbul nüfusuna kayıtlı olduğu, %64.2’sinde (196.3 çift her ikisinin nüfus kaydının İstanbul dışında olduğu saptanmıştır. Boşanma sonrası eşler ve çocukları ruhsal ve ekonomik sorunlarla karşı karşıya kalmaktadır. Sosyal güvenceleri, eşlerin nafaka durumları, işsizlik ve çocukların eğitini durumu göz önüne alındığında sosyal destek mekanizmalarının daha ila güçlendirilmesi toplum ruh sağlığı açısından faydalı olacaktır. Anahtar Kelimeler: Boşanma, boşanma nedenleri.

    12. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on Dietary Reference Values for energy

      DEFF Research Database (Denmark)

      Tetens, Inge

      Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies (NDA) derived dietary reference values for energy, which are provided as average requirements (ARs) of specified age and sex groups. For children and adults, total energy expenditure (TEE...

    13. Portable system for periodical verification of area monitors for neutrons; Sistema portatil para verificacao periodica de monitores de area para neutrons

      Energy Technology Data Exchange (ETDEWEB)

      Souza, Luciane de R.; Leite, Sandro Passos; Lopes, Ricardo Tadeu, E-mail: rluciane@ird.gov.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Energia Nuclear; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da; Pereira, Walsan W., E-mail: karla@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI). Lab. de Neutrons

      2009-07-01

      The Neutrons Laboratory develops a project viewing the construction of a portable test system for verification of functioning conditions of neutron area monitors. This device will allow to the users the verification of the calibration maintenance of his instruments at the use installations, avoiding the use of an inadequate equipment related to his answer to the neutron beam response

    14. Nasturi Toplumunda Hayvan Yetiştiriciliği ve Ticareti (XIX. Yüzyılın İkinci Yarısında)

      OpenAIRE

      DALYAN, Murat Gökhan

      2010-01-01

      XIX. Yüzyılda Hakkâri ve Urmiye bölgesinde yaşayan Nasturiler arasında ekonomik olarak hayvancılık mühim bir yer işgal etmiştir. Beslenen hayvanların tür olarak dağılışında genel olarak coğrafi ve tarım alanlarının yapısı etkili olmuştur. Bu bağlamda tarım alanlarının fazla olduğu Urmiye’de büyükbaş hayvancılık gerçekleştirilirken; Hakkâri dağlarında ise daha çok küçükbaş hayvancılık yapılmıştır. Yük hayvanı olarak da özelikle engebeli arazi yapısından dolayı katır beslenmiştir. Nasturiler ar...

    15. Küresel Ekonomik Kriz Türkiye İşgücü Piyasasında Cinsiyet Eşitsizliğini Derinleştirdi mi?

      OpenAIRE

      ÇETİNKAYA, Emel; YILDIRIMALP, Sinem

      2013-01-01

      İşgücü piyasalarında cinsiyet eşitsizliği, tüm dünyada olduğu gibi Türkiye işgücü piyasasında da önemli bir sorun olarak karşımıza çıkmaktadır. Zaman zaman yaşanan krizler işgücü piyasalarını ve özellikle kadın işgücünü olumsuz yönde etkilemektedir. 2007 yılında ABD’de başlayan küresel ekonomik kriz tüm ülke ekonomileri gibi Türkiye ekonomisini ve işgücü piyasalarını da 2008 yılının özellikle ikinci yarısından itibaren ciddi bir şekilde etkilemeye başlamıştır. Bu çalışma, küresel ekonomik kri...

    16. 30 CFR 77.906 - Trailing cables supplying power to low-voltage mobile equipment; ground wires and ground check...

      Science.gov (United States)

      2010-07-01

      ... portable or mobile equipment from low-voltage three-phase resistance grounded power systems shall contain... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables supplying power to low-voltage... STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage...

    17. Design of a compact low-power human-computer interaction equipment for hand motion

      Science.gov (United States)

      Wu, Xianwei; Jin, Wenguang

      2017-01-01

      Human-Computer Interaction (HCI) raises demand of convenience, endurance, responsiveness and naturalness. This paper describes a design of a compact wearable low-power HCI equipment applied to gesture recognition. System combines multi-mode sense signals: the vision sense signal and the motion sense signal, and the equipment is equipped with the depth camera and the motion sensor. The dimension (40 mm × 30 mm) and structure is compact and portable after tight integration. System is built on a module layered framework, which contributes to real-time collection (60 fps), process and transmission via synchronous confusion with asynchronous concurrent collection and wireless Blue 4.0 transmission. To minimize equipment's energy consumption, system makes use of low-power components, managing peripheral state dynamically, switching into idle mode intelligently, pulse-width modulation (PWM) of the NIR LEDs of the depth camera and algorithm optimization by the motion sensor. To test this equipment's function and performance, a gesture recognition algorithm is applied to system. As the result presents, general energy consumption could be as low as 0.5 W.

    18. Yoğurt Yapımında Yararlanılan L. bulgaricus ve S. thermophilus’un Proteolitik Aktivitelerinin Belirlenmesi

      Directory of Open Access Journals (Sweden)

      Sevda Kılıç

      2015-02-01

      Full Text Available Yoğurt bakterilerinin süte aşılandıktan sonra enzimatik etkinlikleri sonucu proteinleri parçalamaları olayına proteoliz adı verilir. Bu olay sırasında ortamda gerekli gelişme faktörleri meydana geldiğinden S. thermophilus’un gelişmesi ve çoğalması hızlandırılmış olur. Simbiyotik faaliyet gösteren bu bakteriler için gerekli ve yararlı olan proteoliz olayının yoğurt yapımında ancak belirli bir düzeyde meydana gelmesi istenir. ASPERGER, tirosin aminoasiti ile aroma oluşumu arasında bir ilişkinin olduğunu, tirosin içeriğinin 0.05-0.1 mg/ml olması durumunda yoğurtların istenen aromaya sahip olabileceğini bildirmiştir. 0.125 mg/ml tirosin içeren yoğurt örneklerinde ise hafif acı tat oluştuğu bildirilmiştir. Bundan hareketle yoğurt bakterileri olan L. bulgaricus ile S. thermophilus’ a ait suşların proteolitik aktiviteleri HULL yöntemine göre tirosin ekivalantı üzerinden belirlenmeye çalışılmıştır. Araştırmada genellikle yüksek asitlik oluşturabilen L. bulgaricus suşlarının daha fazla proteolitik aktivite gösterdikleri saptanmıştır. Ancak bütün bakteri suşları için bu durumun geçerli olmadığı da belirlenmiştir. 20 L. bulgaricus suşuna ait değerlerin 0.105-0.215 mg tirosin/ml sınırları arasında değiştiği gözlenmiştir. S. thermophilus’un denemeye alınan 20 suşu için saptanan değerler de 0.080-0.070 mg tirosin/ml arasında belirlenmiş olup değerlerin L. bulgaricus’ a ait değerlerden çok düşük olduğu anlaşılmıştır.

    19. EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA); Scientific Opinion on Dietary reference values for water

      DEFF Research Database (Denmark)

      Tetens, Inge

      This Opinion of the EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA) deals with the setting of dietary reference values for water for specific age groups. Adequate Intakes (AI) have been defined derived from a combination of observed intakes in population groups with desirable...

    20. Field portable low temperature porous layer open tubular cryoadsorption headspace sampling and analysis part I: Instrumentation.

      Science.gov (United States)

      Bruno, Thomas J

      2016-01-15

      Building on the successful application in the laboratory of PLOT-cryoadsorption as a means of collecting vapor (or headspace) samples for chromatographic analysis, in this paper a field portable apparatus is introduced. This device fits inside of a briefcase (aluminum tool carrier), and can be easily transported by vehicle or by air. The portable apparatus functions entirely on compressed air, making it suitable for use in locations lacking electrical power, and for use in flammable and explosive environments. The apparatus consists of four aspects: a field capable PLOT-capillary platform, the supporting equipment platform, the service interface between the PLOT-capillary and the supporting equipment, and the necessary peripherals. Vapor sampling can be done with either a hand piece (containing the PLOT capillary) or with a custom fabricated standoff module. Both the hand piece and the standoff module can be heated and cooled to facilitate vapor collection and subsequent vapor sample removal. The service interface between the support platform and the sampling units makes use of a unique counter current approach that minimizes loss of cooling and heating due to heat transfer with the surroundings (recuperative thermostatting). Several types of PLOT-capillary elements and sampling probes are described in this report. Applications to a variety of samples relevant to forensic and environmental analysis are discussed in a companion paper. Published by Elsevier B.V.

    1. Bıldırcın ve Ördek Yumurtalarında Maya-Küf ve Total Bakteri Açısından İncelenmesi

      Directory of Open Access Journals (Sweden)

      Işın Var

      2015-02-01

      Full Text Available Bıldırcın yumurtası, besin değeri yönünden tavuk yumurtasından oransal olarak daha zengin kabul edilmektedir. Daha çok salata, pasta, mayonez vb. yapımında yaygın olarak kullanılan ördek yumurtası (Pekin ördeği tavuk yumurtasına göre daha büyük olup, ağırlıkları 70-90 g arasında değişmektedir. Bıldırcın yumurtası son yıllarda özellikle küçük çocuk ve yaşlı beslenmesinde önem kazanmıştır. Bunun yanısıra bazı hastalıkların tedavisi amacıyla da halk arasında oldukça yaygın kullanılmaktadır. Özellikle çiğ olarak tüketilen bıldırcın yumurtaları zaman zaman içerdikleri patojen mikroorganizmalarla tehlikeli olabilmektedirler. Bu çalışmada bıldırcın ve ördek yumurtalarında maya-küf ve total bakteri aranmıştır. Bıldırcın ve ördek yumurtalarının özellikle kabuğunda hem total bakteri hem de maya-küf bulunmuştur. Bıldırcın yumurtasının akı ve sarısında ise zaman zaman kontaminasyonla karşılaşılmıştır.

    2. Utilization of portable effluent wastewater in brick manufacturing

      International Nuclear Information System (INIS)

      EI-Mahllawy, M.S.; El-Sokkary, T.M.

      2005-01-01

      Portable wastewater is produced from sedimentation and filtration tanks in portable water treatment plants. Usually, this useless wastewater is drained into River Nile Canal and not to the sewer system causing a potential pollution. Wastewater has been taken from Portable Treatment Plant located at Qalubia Province, Delta, Egypt. Evaluation of raw materials was carried out by using X-ray diffraction (XRD), X-ray fluorescence (XRF), thermal analyses (DTA and TGA) as well as plasticity and drying sensitivity coefficient (DSC) measurements. Technological properties of fired bricks were investigated according to Egyptian and American Specifications. The obtained experimental results encourage substitution of the drained portable wastewater for the tap water in bricks manufacturing. Thus, utilization of the studied portable effluent wastewater in such industry is possible and fulfills the double target of saving drinking water used in clay bricks manufacturing, rather than its environmental pollution prevention. Keywords: Portable wastewater, tap water, clay building bricks, physicomechanical properties

    3. Telepositional portable real time radiation monitoring system

      International Nuclear Information System (INIS)

      Talpalariu, Jeni; Matei, Corina; Popescu, Oana

      2010-01-01

      Technology development for complex portable networks is on going to meet the area dosimetry challenge, improving the basic design using new telepositional GPS satellite methods and GSM terrestrial civil radio transmission networks. The system and devices proposed overcome the limitations of fixed and portable dosimeters, providing wireless real time radiations data and geospatial information's means, using many portable dosimeter stations and a mobile dosimeter computerised central console. (authors)

    4. Portable shift register

      International Nuclear Information System (INIS)

      Halbig, J.K.; Bourret, S.C.; Hansen, W.J.; Hicks, D.V.; Klosterbuer, S.F.; Krick, M.S.

      1994-01-01

      An electronics package for a small, battery-operated, self-contained, neutron coincidence counter based on a portable shift-register (PSR) has been developed. The counter was developed for applications not adequately addressed by commercial packages, including in-plant measurements to demonstrate compliance with regulations (domestic and international), in-plant process control, and in-field measurements (environmental monitoring or safeguards). Our package's features, which address these applications, include the following: Small size for portability and ease of installation;battery or mains operation; a built-in battery to power the unit and a typical detector such as a small sample counter, for over 6 h if power lines are bad or noisy, if there is a temporary absence of power, or if portability is desired; complete support, including bias, for standard neutron detectors; a powerful communications package to easily facilitate robust external control over a serial port; and a C-library to simplify creating external control programs in computers or other controllers. Whereas the PSR specifically addresses the applications mentioned above, it also performs all the measurements made by previous electronics packages for neutron coincidence counters developed at Los Alamos and commercialized. The PSR electronics package, exclusive of carrying handle, is 8 by 10 by 20 cm; it contains the circuit boards, battery, and bias supply and weighs less than 2 kg. This instrument package is the second in an emerging family of portable measurement instruments being developed; the first was the Miniature and Modular Multichannel Analyzer (M 3 CA). The PSR makes extensive use of hardware and software developed for the M 3 CA; like the M 3 CA, it is intended primarily for use with an external controller interfaced over a serial channel

    5. SPECIFIC DEGRADATION STRUCTURE FEATURES AND MECHANICAL PROPERTIES OF FURNACE AND HEAT POWER EQUIPMENT ELEMENTS AFTER LONG-TERM OPERATION

      Directory of Open Access Journals (Sweden)

      F. I. Panteleenko

      2012-01-01

      Full Text Available The paper presents results of investigations on structure and mechanical properties of technological equipment elements made of heat-resistant steels. A scale of chrome and molybdenum steel microstructure degradation based on evaluation of  coagulated carbide size and material mechanical properties (a point from 0-operation without time limits, up to 4-operation prohibition has been proposed in the paper. It has been  established that an analysis of  steel microstructure directly on equipment elements by means of a portable microscope is an efficient express method for evaluation of equipment condition and structures due to control of material structure degradation rate of a diagnosed object.

    6. Portable radiation monitors

      International Nuclear Information System (INIS)

      Masui, Kaoru; Ishikura, Takeshi; Inui, Daisuke

      2007-01-01

      This paper presents an overview of typical portable radiation monitors and introduces Fuji Electric's latest models. The overview describes the types, uses and performance of ion chamber survey meters, GM survey meters and neutron ambient dose equivalent rate meters. Fuji Electric's new model of a wide-energy-range X/gamma ray survey meter which measures low energy X-rays up to 8 keV, a battery-powered environmental dosemeter system which measures dose history and is capable of continuous measurement with batteries over a year, and a portable monitoring post which measures dose rates from background to 10 8 nGy/h and transmits data by cellular phone are introduced, and their specifications and performance are described. (author)

    7. Portable direct methanol fuel cell systems

      Science.gov (United States)

      Narayanan, S. R.; Valdez, T. I.

      2002-01-01

      This article includes discussion of the specific power and power density requirements for various portable system applications, the status of stack technology, progress in the implementation of balance-of-plant designs, and a summary of the characteristics of various DMFC portable power source demonstrations.

    8. The Economics of Educational Software Portability.

      Science.gov (United States)

      Oliveira, Joao Batista Araujo e

      1990-01-01

      Discusses economic issues that affect the portability of educational software. Topics discussed include economic reasons for portability, including cost effectiveness; the nature and behavior of educational computer software markets; the role of producers, buyers, and consumers; potential effects of government policies; computer piracy; and…

    9. EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA); Scientific Opinion on establishing Food-Based Dietary Guidelines

      DEFF Research Database (Denmark)

      Tetens, Inge

      This Opinion of the EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA) provides guidance on the translation of nutrient based dietary advice into guidance, intended for the European population as a whole, on the contribution of different foods or food groups to an overall diet...

    10. One of the First Portable Macs

      CERN Multimedia

      1989-01-01

      It was one of the first portable macs released. The Portable had many new advances in mobile computing : The display was crispy clear, and looked beautiful when used in daylight ; The Portable came with a Lead-acid gel/cell battery that could run a anywhere from 6 -12 hours ; It supported to internal hard drives, and an external one. The reaction to the laptop was weak because it was slow, it had no capacity for expansion, it weighed heavily, its price was expensive. It has been stayed 1 year and half on the market.

    11. Making Nuclear Malaysia Email Archives Portable

      International Nuclear Information System (INIS)

      Shaharum Ramli

      2013-01-01

      Nuclear Malaysia e-mails can be accessed from any computer and anywhere, even worldwide, via web access. However, this mobility is lost when the e-mails are moved to a personal computer into archive files such as Microsoft Outlook data files. Outlook e-mail archives can only be read on the computer where it is stored. This removal has to be done because of storage space constraints on the e-mail server. This paper shows how e-mail archives can be made portable, brought and read anywhere using a free portable e-mail client application such as Mozilla Thunderbird, Portable Edition. (author)

    12. Maintenance of fire systems and equipment at Virginia Power

      International Nuclear Information System (INIS)

      Doubrely, E.B. Jr.

      1989-01-01

      The basics of fire protection systems maintenance are well codified and documented in the National Fire Codes published by the National Fire Protection Association. In addition, Insurers often promulgate minimum standards for fire protection systems design and maintenance to which they attach conditions of insurability. Regulatory agencies and even in-house corporate policies can impact the maintenance of fire protection systems and equipment. This presentation will focus on the various methods and alternate ways of performing system maintenance, whether required by code, insurer, or by some regulatory commitment at Virginia Powers North Anna and Surry nuclear power stations. The approach to performing similar work is handled differently at each station. This difference can be attributed to proximity to outside assistance as well as plant philosophy. In addition to station maintenance practices, a discussion of in-house servicing of portable fire suppression equipment is offered. 1 tab

    13. UK MOD research on H{sub 2} storage and generation methods for soldier-portable fuel cells

      Energy Technology Data Exchange (ETDEWEB)

      Browning, D.J. [Defence Evaluation Research Agency, Hampshire (United Kingdom)

      2000-05-01

      The research which the Defence Evaluation and Research Agency (DERA) has conducted on hydrogen storage and production methods was presented and their applicability to soldier portable applications was discussed. Polymer electrolyte membrane (PEM) fuel cells are considered to be the future power source for solider-portable equipment such as army radios. Advances in fuel cell technology has resulted in improvements in specific power and power density as well as reductions in Pt loading and cost. However, a viable in-service power source is still required. This fuel source is likely to be hydrogen because it has a high energy per unit weight and has a simple reaction with oxygen to produce water as the only by-product. In the future, methanol may be used as the fuel source but currently methanol fuel cells demonstrate poorer performance than those running on hydrogen. A vital part of a fuel cell system, therefore, is hydrogen storage, of which there are two basic types; physical and chemical storage. In addition to weight, other important factors to be considered in a storage system are cost, reliability and safety. This paper described each physical storage method including hydrogen stored as a compressed gas, as a cryogenic liquid, reversibly absorbed in intermetallic alloys and reversibly adsorbed onto carbon materials such as nonofibres. Liquid hydrogen storage is only feasible for larger scale applications such as electric vehicles and is not practical for portable applications. A man-portable fuel cell is likely to be either pressure cylinders or reversible metal hydrides. 6 refs., 1 tab., 10 figs.

    14. Roma Hukuku’nda Gemi, Han ve Ahır İşletenlerin Receptum Sorumluluğu

      Directory of Open Access Journals (Sweden)

      Mehmet YEŞİLLER

      2013-04-01

      Full Text Available Çalışmamızda Roma Hukuku'nda gemi, han ve ahır işleten kimselerin sorumluluklarına ilişkin düzenlemeler ele alınmıştır. Roma?da özellikle gemi, han ve ahır işleten kimselerin yanlarında çalıştırdıkları kişilerin güvenilir olmamasından dolayı, taraflar arasındaki istisna sözleşmesinden kaynaklanan custodia sorumluluğuna ek olarak "actio de damno aut furto adversus nautas, caupones, stabularios ve receptum, nautae, cauponis, stabularii" sorumluluklarının düzenlendiği kaynaklardan anlaşılmaktadır. Praetor Edictum'larıyla sağlanan ve haksız fiil benzerlerine dayanan söz konusu bu uygulamaların, Roma'da istisna sözleşmesinin koruyamadığı alana ilişkin olarak geniş uygulama imkanı buldukları görülmektedir.

    15. Method and Apparatus for the Portable Identification of Material Thickness and Defects Using Spatially Controlled Heat Application

      Science.gov (United States)

      Cramer, K. Elliott (Inventor); Winfree, William P. (Inventor)

      1999-01-01

      A method and a portable apparatus for the nondestructive identification of defects in structures. The apparatus comprises a heat source and a thermal imager that move at a constant speed past a test surface of a structure. The thermal imager is off set at a predetermined distance from the heat source. The heat source induces a constant surface temperature. The imager follows the heat source and produces a video image of the thermal characteristics of the test surface. Material defects produce deviations from the constant surface temperature that move at the inverse of the constant speed. Thermal noise produces deviations that move at random speed. Computer averaging of the digitized thermal image data with respect to the constant speed minimizes noise and improves the signal of valid defects. The motion of thermographic equipment coupled with the high signal to noise ratio render it suitable for portable, on site analysis.

    16. A Portable Ultrasound System for Non-Invasive Ultrasonic Neuro-Stimulation.

      Science.gov (United States)

      Qiu, Weibao; Zhou, Juan; Chen, Yan; Su, Min; Li, Guofeng; Zhao, Huixia; Gu, Xianyi; Meng, De; Wang, Congzhi; Xiao, Yang; Lam, Kwok Ho; Dai, Jiyan; Zheng, Hairong

      2017-12-01

      Fundamental insights into the function of the neural circuits often follows from the advances in methodologies and tools for neuroscience. Electrode- and optical- based stimulation methods have been used widely for neuro-modulation with high resolution. However, they are suffering from inherent invasive surgical procedure. Ultrasound has been proved as a promising technology for neuro-stimulation in a non-invasive manner. However, no portable ultrasound system has been developed particularly for neuro-stimulation. The utilities used currently are assembled by traditional functional generator, power amplifier, and general transducer, therefore, resulting in lack of flexibility. This paper presents a portable system to achieve ultrasonic neuro-stimulation to satisfy various studies. The system incorporated a high voltage waveform generator and a matching circuit that were optimized for neuro-stimulation. A new switching mode power amplifier was designed and fabricated. The noise generated by the power amplifier was reduced (about 30 dB), and the size and weight were smaller in contrast with commercial equipment. In addition, a miniaturized ultrasound transducer was fabricated using Pb(Mg 1/3 Nb 2/3 )O 3 -PbTiO 3 (PMN-PT) 1-3 composite single crystal for the improved ultrasonic performance. The spatial peak temporal average pressure was higher than 250 kPa in the range of 0.5-5 MHz. In vitro and in vivo studies were conducted to show the performance of the system.

    17. Damla Sulama Koşullarında Aşılı ve Aşısız Karpuzlarda Bitki, Su ve Verim İlişkilerinin İrdelenmesi

      Directory of Open Access Journals (Sweden)

      Selçuk ÖZMEN

      2014-09-01

      Full Text Available Bu çalışma, 2006-2008 yılları arasında Çukurova Üniversitesi, Ziraat Fakültesi, Tarımsal Yapılar ve Sulama Bölümü deneme alanında yürütülmüştür. Araştırmada, damla sulama koşullarında aşılı ve aşısız karpuzlarda bitki, su ve verim ilişkileri irdelenmiştir. Denemede; tam sulanan aşılı (Crimson Tide+Jumbo:CTJ ve aşısız (Crimson Tide: CT konuları ele alınmıştır. Sulama suyu, sulama aralıkları arasında oluşan toplam A Sınıfı buharlaşma kabından okunan değerlere göre hesaplanmıştır. Çalışmada, konulara göre, sulama suyu (IW ve bitki su tüketimleri (ET, sırasıyla, 266.2–413.5 mm (12–16 sulama ve 433.1-520.6 mm arasında değişmiş; en yüksek IW ve mevsimlik ET ise, sırasıyla, 413.5 mm ve 520.6 mm ile CTJ konusundan 2006 yılında elde edilmiştir. Karpuz bitkisinde en yüksek ortalama aylık ET, 214.0 mm ile CTJ konusunda Mayıs ayında ölçülmüş; bu ayda ortalama çim kıyas bitki su tüketimi (ETo, 163.1 mm olarak belirlenmiştir. Bitki katsayısı (Kc değerlerinin; deneme yılları için, başlangıç, mevsim ortası ve mevsim sonudönemlerinde, sırasıyla, 0.240.67, 0.87-1.66 ve 0.83-0.93 olarak değiştiği saptanmıştır. Son yılki çalışmada; toplam kök yoğunluğunun aşılı konularda aşısızlara kıyasla % 4 daha fazla; yaprak su potansiyeli (YSP değerlerlerinin -0.20 ile -0.70 MPa arasında değiştiği ve aşılı konuların daha yüksek YSP değerlerine sahip olduğu saptanmıştır. Aşılama ile verim, toplam su kullanma randımanı (TWUE ve su kullanım randımanı (IWUE artarken sulama suyunun ET içerisindeki kullanım oranı (IWc aşısız konularında daha yüksek olduğu belirlenmiştir. En yüksek verim 712.8 kg/ha ile CTJ konusundan 2008 yılından elde edilmiştir

    18. PORTABLE PEM FUEL CELL SYSTEM: WATER AND HEAT MANAGEMENT

      Directory of Open Access Journals (Sweden)

      SITI NAJIBAH ABD RAHMAN

      2016-07-01

      Full Text Available Portable polymer electrolyte membrane (PEM fuel cell power generator is a PEM fuel cell application that is used as an external charger to supply the demand for high energy. Different environments at various ambient temperatures and humidity levels affect the performance of PEM fuel cell power generators. Thermal and water management in portable PEM fuel cells are a critical technical barrier for the commercialization of this technology. The size and weight of the portable PEM fuel cells used for thermal and water management systems that determine the performance of portable PEM fuel cells also need to be considered. The main objective of this paper review was to determine the importance of water and thermal management systems in portable PEM fuel cells. Additionally, this review investigated heat transfer and water transport in PEM fuel cells. Given that portable PEM fuel cells with different powers require different thermal and water management systems, this review also discussed and compared management systems for low-, medium-, and high-power portable PEM fuel cells.

    19. Equipment concepts for dry intercask transfer of spent fuel

      International Nuclear Information System (INIS)

      Schneider, K.J.

      1983-07-01

      This report documents the results of a study of preconceptual design and analysis of four intercask transfer concepts. The four concepts are: a large shielded cylindrical turntable that contains an integral fuel handling machine (turntable concept); a shielded fuel handling machine under which shipping and storage casks are moved horizontally (shuttle concept); a small hot cell containing equipment for transferring fuel between shipping and storage casks (that enter and leave the cell on carts) in a bifurcated trench (trench concept); and a large hot cell, shielded by an earthen berm, that houses equipment for handling fuel between casks that enter and leave the cell on a single cart (igloo concept). The casks considered in this study are most of the transport casks currently operable in the USA, and the storage casks designated REA-2023 and GNS Castor-V. Exclusive of basic services assumed to be provided at the host site, the design and capital costs are estimated to range from $9 to $13 million. The portion of capital costs for portable equipment (for potential later use at another site) was estimated to range from 70% to 98%, depending on the concept. Increasing portability from a range of 70 to 90% to 98% adds $2 to 4 million to the capital costs. Operating costs are estimated at about $2 million/year for all concepts. Implementation times range from about 18 months for the more conventional systems to 40 months for the more unique systems. Times and costs for relocation to another site are 10 to 14 months and about $1 million, plus shipping costs and costs of new construction at the new site. All concepts have estimated capacities for fuel transfer at least equal to the criterion set for this study. Only the hot cell concepts have capability for recanning or repair of canisters. Some development is believed to be required for the turntable and shuttle concepts, but none for the other two concepts

    20. Tam Zamanında Üretim Sistemlerinde Hata Önleyiciler: Poka-

      OpenAIRE

      BAY, Murat; ÇİÇEK, Ercan

      2007-01-01

      Günümüzde, birçok işletme yalın üretime üretim performansının artması için geçmektedir. İstatistiksel proses kontrol gibi araçlar hatayı göstermekte, ancak önlememektedir. Poka-Yoke’nin altında yatan temel düşünce ise, çalışanların dikkatsizliklerini önlemektir. Bu çalışmada, poka-yoke sistemleri özellikle kurulum ve kullanım maliyetinin düşük olması ve maliyet kazancı olduğu için incelenmiştir

    1. Bagworm bags as portable armour against invertebrate predators

      Directory of Open Access Journals (Sweden)

      Shinji Sugiura

      2016-02-01

      Full Text Available Some animals have evolved the use of environmental materials as “portable armour” against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a potential predator Calosoma maximoviczi (Coleoptera: Carabidae. Under laboratory conditions, all bagworm larvae were attacked by carabid adults, but successfully defended themselves against the predators’ mandibles using their own bags. The portable bags, which are composed mainly of host plant twigs, may function as a physical barrier against predator mandibles. To test this hypothesis, I removed the twig bags and replaced some with herb leaf bags; all bag-removed larvae were easily caught and predated by carabids, while all bag-replaced larvae could successfully defend themselves against carabid attacks. Therefore, various types of portable bags can protect bagworm larvae from carabid attacks. This is the first study to test the defensive function of bagworm portable bags against invertebrate predators.

    2. Bagworm bags as portable armour against invertebrate predators.

      Science.gov (United States)

      Sugiura, Shinji

      2016-01-01

      Some animals have evolved the use of environmental materials as "portable armour" against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae) construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a potential predator Calosoma maximoviczi (Coleoptera: Carabidae). Under laboratory conditions, all bagworm larvae were attacked by carabid adults, but successfully defended themselves against the predators' mandibles using their own bags. The portable bags, which are composed mainly of host plant twigs, may function as a physical barrier against predator mandibles. To test this hypothesis, I removed the twig bags and replaced some with herb leaf bags; all bag-removed larvae were easily caught and predated by carabids, while all bag-replaced larvae could successfully defend themselves against carabid attacks. Therefore, various types of portable bags can protect bagworm larvae from carabid attacks. This is the first study to test the defensive function of bagworm portable bags against invertebrate predators.

    3. A high resolution portable spectroscopy system

      International Nuclear Information System (INIS)

      Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.; Bhatnagar, P.V.; Pande, S.S.; Padmini, S.

      2003-01-01

      Full text: This paper describes the system details of a High Resolution Portable Spectroscopy System (HRPSS) developed at Electronics Division, BARC. The system can be used for laboratory class, high-resolution nuclear spectroscopy applications. The HRPSS consists of a specially designed compact NIM bin, with built-in power supplies, accommodating a low power, high resolution MCA, and on-board embedded computer for spectrum building and communication. A NIM based spectroscopy amplifier and a HV module for detector bias are integrated (plug-in) in the bin. The system communicates with a host PC via a serial link. Along-with a laptop PC, and a portable HP-Ge detector, the HRPSS offers a laboratory class performance for portable applications

    4. Industrial gamma radiography on a building site with a portable device. Recommendations to operators - gammagraphy sheet ED 4243; Recommendations to intervening companies (subcontractors) -gammagraphy sheet ED 4244; Recommendations to user companies - gammagraphy sheet ED 4245

      International Nuclear Information System (INIS)

      Vaisseau, Bernard; Bourdon, Patrick; Laurent, Pierre; Servent, Jean-Pierre; Biau, Alain

      2006-12-01

      Based on best practices, three sheets indicate sets of recommendations regarding the use of an industrial gamma radiography portable device on a building site either by operators, intervening companies (or subcontractors), or user companies. As far as operators are concerned, recommendations concern preparation and transport, arrival on the building site, examination performance, end of examination, occurrence of an incident other than radiological, and occurrence of a radiological incident. As far as subcontractors are concerned, recommendations concern the actors of the intervening company, the permanent storage site of portable devices, the film development laboratory, portable devices and their accessories, other equipment used for examination, vehicles, operators, intervention preparation, the return on experience, and the immediate processing of anomalies. As far as user companies are concerned, recommendations concern actors of the user company, the definition of the operation, the previous inspection of premises and the definition of a prevention plan, the storage of equipment containing depleted uranium, loading and unloading operations, the coordination of exposure doses, the immediate processing of anomalies, and the return on experience. Moreover, the three sheets indicate the associated legal texts

    5. Barış Harekâtı Sonrasında Adana’dan Kıbrıs’a Gerçekleştirilen Nüfus Nakli (1975-1976)

      OpenAIRE

      ÇANAK, Erdem

      2015-01-01

      1571-1878 yılları arasında Osmanlı Devleti’nin hâkimiyeti altında bulunan Kıbrıs, 1878 yılında geçici olarak, Lozan Antlaşması ile de resmen İngiltere’ye geçmiştir. Bu durumdan faydalanmak isteyen Rumlar da “Enosis”e yönelik faaliyetlerine hız vermişlerdir. Adadaki Türklerin var olma mücadelesine neden olan bu süreç, 1974 Barış Harekâtı ile neticelenmiştir. Ancak Türkler, Barış Harekâtı’na kadar olan dönemde maruz kaldıkları baskıdan dolayı zaman zaman başta Türkiye olmak üzere dünyanın farkl...

    6. Point-of-Care Test Equipment for Flexible Laboratory Automation.

      Science.gov (United States)

      You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

      2014-08-01

      Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

    7. Smart portable rehabilitation devices

      Directory of Open Access Journals (Sweden)

      Leahey Matt

      2005-07-01

      Full Text Available Abstract Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s. Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices

    8. Smart portable rehabilitation devices.

      Science.gov (United States)

      Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

      2005-07-12

      The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design

    9. Vişne ve Nar Suyu ve Konsantratlarında Antosiyaninlerin Degradasyonu

      Directory of Open Access Journals (Sweden)

      Narmela Asafı

      2015-02-01

      Full Text Available Nar ve vişne suyu konsantratlarında antosiyaninlerin parçalanması üzerine sıcaklığın etkisi incelenmiştir. 70°Bx'lik konsantratlardan 45°Bx ve 15° Bx lik örnekler hazırlanarak -18°C, 5°C, 20°C ve 37°C depolanmıştır. Depolanma süresince, sıcaklık dercesine bağlı olarak değişik aralıklarla alman örneklerde antosiyanin kaybı saptanarak parçalanma hızı incelenmiştir. Elde edilen bulgulara göre antosiyaninlerin parçalanma­sı birinci dereceden bir reaksiyon kinetiğine göre gelişmektedir. Tüm örneklerde beklendiği gibi sıcaklık derecesi yükseldikçe antosiyaninlerin degradasyon hızları artmaktadır. Örneğin 15° Bx'lik vişne suyunda -18°C'de hız konsantı k=0.534 x 10-3 gün-1 olduğu halde, 37°C'de k= 184 x 10-3 gün-1 'e yükselmiştir. Aynı şekilde 15° Bx'lik vişne suyunda -18°C'de hız konstantı k= 0.203 x 10-3 gün-1 olduğu halde 37°C'de k= 94 x10-3 gün-1'e yükselmiştir. Ayrıca reaksiyonun sıcaklığa bağımlılığı, Arrhenius eşitliğinden yararlanarak açıklanmaya çalışılmıştır. Nar suyu ve konsantratlannda antosiyaninlerin degradasyon hızı, vişne suyu ve konsantratlarında olduğundan daha yüksektir. Böylece nar suyu ve konsantratlarında depolama süresince sıcaklığa bağlı olarak hızla renk kaybı oluşmaktadır. Ayrıca doğal briksindeki vişne suyunda antosiyaninler, konsantratlarda olduğundan daha stabil olduğu halde nar suyunda bunun aksine konsantratlardaki antosiyaninlerin daha stabil ol­duğu anlaşılmaktadır.

    10. Design and setup of a portable stirring device for transfer and dissolution of 99Mo applied to the use of a 99mTc generator

      International Nuclear Information System (INIS)

      Lopez, Yon; Rojas, Jorge

      2014-01-01

      This work shows the design and implementation of a portable magnetic stirring device for transfer and efficient dissolution of Mo O 3 coupled to a 99m Tc generator prototype. The development of this equipment will enable an efficient and safe transfer of 99 Mo at a 2 Ci of maximum activity from the nuclear reactor Huarangal to the point of operation of the 99m Tc generator equipment. This article describes the mechanical design, volume and shielding calculation, the electronics design and the programmable speed control of the stirring system for radioactive samples. (authors).

    11. Tıbbi Adaçayı (Salvia officinalis L.’nda Farklı Hasat Zamanlarının Uçucu Yağ ve Fenolik Bileşikler ile Antioksidan Aktivite Üzerine Etkisi

      Directory of Open Access Journals (Sweden)

      Müge BAŞYİĞİT

      2016-11-01

      Full Text Available Bu araştırma, bir yıl süreyle 12 ayı temsil edecek şekilde farklı zamanlarda hasat edilen tıbbi adaçayı (Salvia officinalis L.’nın herba ve yaprak verimi, yaprakların taşıdığı uçucu yağ oranı ve kompozisyonu, ekstrede  Folin-Ciocalteu kolorimetrik metodu kullanılarak toplam fenolik madde miktarı, fenolik bileşikleri, serbest radikal süpürücü aktivitesi (DPPH ve demir iyonu indirgeme gücü (FRAP yöntemlerine göre antioksidan aktivitelerini belirlemek amacıyla yapılmıştır. Tıbbi adaçayında taze herba verimi 500.0-961.0 kg/da, kuru herba verimi 223.4-556.6 kg/da, kuru yaprak verimi 129.6-367.2 kg/da, uçucu yağ oranı %0.83-3.33, toplam fenolik madde miktarı 14.54-30.83 mg/g arasında değişim göstermiştir. Yaz ve güz aylarında hasat edilen bitkilerin herba ve yaprak verimleri, uçucu yağ oranları ve verimleri ile toplam fenolik madde miktarları kış ve bahar aylarında hasat edilen bitkilere göre daha yüksek bulunmuştur. Tıbbi adaçayının uçucu yağ kompozisyonunu oluşturan en önemli bileşenlerin 1,8-sineol (%11.93-31.87, α-tuyon (%15.72-26.26, β-tuyon (%4.51-27.67 ve kamfor (%3.65-23.02 olduğu, 1,8-sineol ve kamfor oranları ilkbahar aylarında daha düşük oranlarda, α- ve β-tuyon oranları ise ilkbahar aylarında daha yüksek oranlarda bulunduğu tespit edilmiştir. Tıbbi adaçayının en önemli fenolik bileşenlerinin ise rosmarinik asit (15.15-100.57 mg/g, naringin (9.59-41.81 mg/g, hesperidin (9.80-53.26 mg/g ve rutin (0.73-10.04 mg/g olduğu, en yüksek antioksidan aktivite Mayıs ve Haziran aylarında biçilen ve en düşük antioksidan aktivite ise Mart ve Nisan aylarında biçilen tıbbi adaçayı yapraklarında gözlenmiştir.

    12. iPad Portable Genius

      CERN Document Server

      McFedries, Paul

      2010-01-01

      Everything everyone wants to know about using the Apple iPad. On January 27, 2010, Apple announced the latest in its line of revolutionary, ultraportable devices - the iPad. iPad Portable Genius is the latest in a line of ultra handy, go-to and goes-with you anywhere guides for getting the most out of a new Apple product. Written to provide readers with highly useful information that's easily accessible, iPad Portable Genius is full of tips, tricks and techniques for maximizing each of the iPad's most popular features.:; Designed in full-color with an Apple look and feel, and written in a hip,

    13. Yeşilırmak Nehir Teraslarında Toprakların Oluşumu ve Sınıflandırılması

      Directory of Open Access Journals (Sweden)

      Alper Durak

      2014-02-01

      Full Text Available Bu çalışmada ana materyali alüviyaller olan, Yeşilırmak nehir terasları üzerinde oluşmuş topraklar incelenmiştir. Bu amaçla çalışma alanında 4 farklı profil açılmıştır. Açılan profillerden horizon esasına göre toplam 27 adet örnek alınmış ve laboratuvarda fiziksel ve kimyasal analizleri yapılmıştır. Tanımlanan profiller Toprak Taksonomisi’ne göre, Alt grup düzeyinde; Kum Ocağı ve Çakıl profilleri Typic Ustipsamments, Havaalanı profili Typic Haplustolls ve Mera profili ise Typic Argiustolls olarak sınıflandırılmıştır. Toprakların pH değerleri 7,38-8,41 arasında değişmekte olup, topraklar hafif ve kuvvetli bazik reaksiyonlu olarak sınıflandırılmıştır. Toprakların çoğunda, pH değerleri profil içinde düzensiz olarak dağılmıştır. Bir kısmında is pH değerlerinde derinliğe bağlı olarak artış görülmüştür. Çalışma alanı topraklarında kireç %0,8-25,4 arasında değişmiştir. Toprakların kireç içerikleri geniş sınırlar içinde değişmesine rağmen, büyük çoğunluğu fazla kireçli olarak sınıflandırılmıştır. Toprakların önemli bir kısmında, kireç profil içinde düzensiz olarak dağılmıştır. Topraklarda organik madde içeriği %0,14-6,11 arasındadır. Toprakların organik madde içerikleri geniş sınırlar içerisinde değişim göstermesine rağmen, büyük çoğunluğunun organik madde içeriği düşük düzeydedir. Organik madde içeriği sadece iki profilin yüzey horizonlarında %4’ün üzerindedir. Çalışma sonunda alüviyal ana materyal, tekstür, topoğrafya ve zamanın; tanımlanan toprakların oluşumunu farklı derecede etkilediği ortaya konmuştur.

    14. Portable Tablets in Science Museum Learning: Options and Obstacles

      Science.gov (United States)

      Gronemann, Sigurd Trolle

      2017-01-01

      Despite the increasing use of portable tablets in learning, their impact has received little attention in research. In five different projects, this media-ethnographic and design-based analysis of the use of portable tablets as a learning resource in science museums investigates how young people's learning with portable tablets matches the…

    15. Water and sediment analysis of touristic places in Guarapuava, PR using a portable EDXRF system

      International Nuclear Information System (INIS)

      Antunes Junior, Osmar R.; Biasi, Gabriel E.V.; Melquiades, Fabio L.; Lopes, Fabio; Appoloni, Carlos R.

      2009-01-01

      The use of the Energy Dispersive X Ray Fluorescence (EDXRF) have increasingly been applied for in situ trace metal analysis in different kinds of samples. Results of a monitoring sampling, in the winter and summer of 2008, respectively, from 6 touristic places in Guarapuava, PR city are presented. The work consisted on the use of a portable EDXRF system constituted by a X-ray tube to excite the samples, a Si-Pin detector, a holder for the excitation-detection system and samples positioning, with the standard data acquisition electronics to register the spectra. The water samples were filtered in membranes for suspended particulate matter retention. After this, APDC precipitation methodology was applied for sample preconcentration with posterior filtering in membranes. So, the dissolved and non dissolved metal fractions were determined separately. Sediment samples were dried at 60 C for 24h and sieved through 60 mesh. Micromatter standards were used for sensitivity determination for membranes samples. For sediments 5 multi-element standards were used and calibration curves were constructed. For water membrane measurements, Fe concentration was quantified from 0.026±0.004 to 5.1±1.0, in mg L -1 . For sediments, considering all the sampling locations, Mn, Cu, Sr, Y and Nb were identified qualitatively, and it was possible to quantify the following range of elements and concentrations, mg Kg -1 : Ca (1977 - 10162), Ti (12494 - 22320), Fe (36972 - 88452), Zn (73 - 185) and Zr (158 - 960). The performance of the equipment was very good and the results are quite satisfactory for portable equipment. (author)

    16. NECSA'S Need to Establish a Nuclear Forensics Specific NDA Facility for On-Site Categorization of Seized Nuclear Materials

      International Nuclear Information System (INIS)

      Boshielo, P.; Mogafe, R.

      2015-01-01

      The increase of nuclear material that are out of regulatory control is becoming a serious concern and threat and thereby continuously seeking urgent interventions and counteractions from the international community aspiring effective control over all nuclear material and peaceful uses of nuclear technologies globally. In South Africa the nuclear forensics initiative approach and its execution have been adopted, established and managed by the South African Nuclear Energy Corporation (NECSA) to support the country's nuclear safeguards system and nuclear security investigations plan to fight against the illicit trafficking of nuclear and radioactive materials. On this nuclear forensics initiative approach adopted by Necsa, the development and later execution of a Non-Destructive Analyses (NDA) facility capability for quick categorization of any seized nuclear material by law-enforcement agencies is currently envisaged as a critical initiative to comprehend nuclear forensics Laboratory analytical or characterization techniques. The main objective for this NDA facility is planned to be used for performing nuclear material screening process for material categorization purposes to generate information and results which will be open to law enforcement agencies for prosecution processes and also for the safeguards reporting to the IAEA (ITDB). The NDA technique is therefore found to be a critical tool needed at NECSA as an Early-Checking-Point or first-line material check point for all seized nuclear materials in determining some characteristics of the materials and collection of data without having to destroy or changing the morphology of the material. (author)

    17. Portable radiography using linear accelerators

      International Nuclear Information System (INIS)

      Reid, D.W.

      1984-01-01

      There are numerous instances where the availability of a portable high-energy radiography machine that could be transported to the inspection site with relative ease would save time, money, and make radiography of permanent installations, such as bridges, possible. One such machine, the Minac built by Schoenberg Radiation Inc., is commercially available. It operates at 9.3 GHz, has an electron energy on target of 3.5 MeV, and an output dose rate of 100 R/min. A second portable accelerator, recently completed at the Los Alamos National Laboratory, operates at 2.998 GHz, has electron energies on target of 6, 8, and 10 MeV, and an output dose rate of 800 R/min at 8 MeV. This paper discusses the need for and applications of portable accelerators for radiography. Physical characteristics and beam parameters of both machines are examined in detail. Problems of operating at higher frequencies to further minimize size and weight are discussed

    18. Bagworm bags as portable armour against invertebrate predators

      OpenAIRE

      Sugiura, Shinji

      2016-01-01

      Some animals have evolved the use of environmental materials as “portable armour” against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae) construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a po...

    19. 30 CFR 75.1703 - Portable electric lamps.

      Science.gov (United States)

      2010-07-01

      ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...

    20. 5 CFR 870.1205 - Electing portability for Option B.

      Science.gov (United States)

      2010-01-01

      ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Electing portability for Option B. 870... portability for Option B. (a) The employing agency must notify the employee/assignee(s) of the loss of coverage and the right to elect portability for Option B either before or immediately after the event...

    1. Freely oriented portable superconducting magnet

      Science.gov (United States)

      Schmierer, Eric N [Los Alamos, NM; Prenger, F Coyne [Los Alamos, NM; Hill, Dallas D [Los Alamos, NM

      2010-01-12

      A freely oriented portable superconducting magnet is disclosed. Coolant is supplied to the superconducting magnet from a repository separate from the magnet, enabling portability of the magnet. A plurality of support assemblies structurally anchor and thermally isolate the magnet within a thermal shield. A plurality of support assemblies structurally anchor and thermally isolate the thermal shield within a vacuum vessel. The support assemblies restrain movement of the magnet resulting from energizing and cooldown, as well as from changes in orientation, enabling the magnet to be freely orientable.

    2. Current state of commercial radiation detection equipment for homeland security applications

      International Nuclear Information System (INIS)

      Klann, R.T.; Shergur, J.; Mattesich, G.

      2009-01-01

      With the creation of the U.S. Department of Homeland Security (DHS) came the increased concern that terrorist groups would attempt to manufacture and use an improvised nuclear device or radiological dispersal device. As such, a primary mission of DHS is to protect the public against the use of these devices and to assist state and local responders in finding, locating, and identifying these types of devices and materials used to manufacture these devices. This assistance from DHS to state and local responders comes in the form of grant money to procure radiation detection equipment. In addition to this grant program, DHS has supported the development of American National Standards Institute standards for radiation detection equipment and has conducted testing of commercially available instruments. This paper identifies the types and kinds of commercially available equipment that can be used to detect and identify radiological material - for use in traditional search applications as well as primary and secondary screening of personnel, vehicles, and cargo containers. In doing so, key considerations for the conduct of operations are described as well as critical features of the instruments for specific applications. The current state of commercial instruments is described for different categories of detection equipment including personal radiation detectors, radioisotope identifiers, man-portable detection equipment, and radiation portal monitors. In addition, emerging technologies are also discussed, such as spectroscopic detectors and advanced spectroscopic portal monitors

    3. 24 CFR 982.636 - Homeownership option: Portability.

      Science.gov (United States)

      2010-04-01

      ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Homeownership option: Portability... Types Homeownership Option § 982.636 Homeownership option: Portability. (a) General. A family may... described in §§ 982.353 and 982.355 apply to the homeownership option and the administrative...

    4. Waste characterization methods at belgoprocess and the importance of NDA

      International Nuclear Information System (INIS)

      Botte, J.; Luycx, P.

      2003-01-01

      Waste characterization in the end cycle becomes more and more important. Several methods are available for a radiological characterization: from copying the waste producers declaration over a calculation based on known characteristics or measured values to combinations of several techniques. The decision on what technique(s) to be used will be based on several criteria. One also has to evaluate at what stage of the waste treatment process the characterization has to be performed. Recently belgoprocess has performed large efforts and investments to assure a good waste characterization. These are concentrated in studies on historical and recent waste, resulting in isotopic vectors and the purchase of several NDA devices in order to cover the whole scala of waste the company treats. The measuring results always need to be integrated with isotopic vectors. (orig.)

    5. EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA); Scientific Opinion on Dietary Reference Values for carbohydrates and dietary fibre

      DEFF Research Database (Denmark)

      Tetens, Inge

      This Opinion of the EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA) deals with the establishment of Dietary Reference Values for carbohydrates and dietary fibre. Nutritionally, two broad categories of carbohydrates can be differentiated: “glycaemic carbohydrates”, i.e. carbohydrates...

    6. EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA); Scientific Opinion on principles for deriving and applying Dietary Reference Values

      DEFF Research Database (Denmark)

      Tetens, Inge

      This Opinion of the EFSA Panel on Dietetic products, Nutrition, and Allergies (NDA) deals with the general principles for development and application of Dietary Reference Values (DRVs). These quantitative reference values for nutrient intakes for healthy individuals and populations are based...

    7. Farklı Durum Çeşitlerinden Mahalli ve Laboratuvar Koşullarında Yapılmış Bulguların Bazı Vitamin ve Mineral İçerikleri

      Directory of Open Access Journals (Sweden)

      Berrin Özkaya

      2015-02-01

      Full Text Available Araştırmada 5 farklı durum buğdayının, bunlardan mahalli ve laboratuvar koşullarında yapılan bulguların bazı kimyasal özellikleri ile tiamin, riboflavin ve mineral içerikleri karşılaştırılmıştır. Buğdayların yapımı sırasında buğdayların tiamin, özellikle de riboflavin miktarları azalmıştır. Mahalli koşullarda yapılan bulgurların tiamin ve riboflavin miktarları laboratuvarda yapılanlara kıyasla biraz düşük çıkmıştır. Bulgurların mineral içerikleri (Fe, Cu, Zn, Mn, Ca ve Mg miktarları yapıldıktan buğdaylara kıyasla daha düşük çıkmış, mahalli ve laboratuvar koşullarında yapılan bulgurların mineral madde miktarlarında önemli bir fark görülmemiştir.

    8. Peyniraltı Suyu Tozundan Hazırlanan Sentetik Besi Ortamında Lactobacillus bulgaricus Suşlarının Oluşturduğu Laktik Asit Miktarı Üzerine bir Araştırma

      OpenAIRE

      Beyatlı, Yavuz; Tulumoğlu, Şener

      1991-01-01

      Peyniraltı suyu tozundan altı farklı sentetik besi ortamı hazırlanmıştır. Bu besi ortamlarında 12 adet L. bulgaricus suşunun oluşturduğu laktik asit miktarları tespit edilmiştir. Katkılı besi ortamlarında oluşan laktik asit miktarları, katkısız besi ortamları ile kıyaslandığında daha fazla bulunmuştur. 12 adet L. bulgaricus suşu arasında en fazla laktik asit üretenlerin L. bulgaricus B1, L. bulgaricus B4 ve L. bulgaricus B11 suşları olduğu görülmüştür.  

    9. New conceptual design of portable bamboo bridge for emergency purposes

      Science.gov (United States)

      Musthaffa, A. A.; Nor, N. M.; Yusof, M. A.; Yuhazri, M. Y.

      2018-02-01

      Portable bridges serve as routes for troops during the military operations and the disaster relief operation. Nowadays, bamboo has been regarded as one of the alternative construction materials for building and bridge structures. This paper presents the conceptual design of the portable bridge. Several types of portable bridges and bamboo bridges are reviewed in the current work. The characteristics, capability and method of construction of each bridge are discussed. Finally, the conceptual of the portable bamboo bridge for emergency purposes is presented. The idea of producing portable bridge is proposed in the current work as it is crucial for providing route for communities affected by natural disasters.

    10. Cloud portability and interoperability issues and current trends

      CERN Document Server

      Di Martino, Beniamino; Esposito, Antonio

      2015-01-01

      This book offers readers a quick, comprehensive and up-to-date overview of the most important methodologies, technologies, APIs and standards related to the portability and interoperability of cloud applications and services, illustrated by a number of use cases representing a variety of interoperability and portability scenarios. The lack of portability and interoperability between cloud platforms at different service levels is the main issue affecting cloud-based services today. The brokering, negotiation, management, monitoring and reconfiguration of cloud resources are challenging tasks

    11. 29 CFR 1910.25 - Portable wood ladders.

      Science.gov (United States)

      2010-07-01

      ... for the construction, care, and use of the common types of portable wood ladders, in order to insure... density wood shall not be used. (ii) [Reserved] (2) [Reserved] (c) Construction requirements. (1... 29 Labor 5 2010-07-01 2010-07-01 false Portable wood ladders. 1910.25 Section 1910.25 Labor...

    12. Development and On-Field Testing of Low-Cost Portable System for Monitoring PM2.5 Concentrations.

      Science.gov (United States)

      N Genikomsakis, Konstantinos; Galatoulas, Nikolaos-Fivos; I Dallas, Panagiotis; Candanedo Ibarra, Luis Miguel; Margaritis, Dimitris; S Ioakimidis, Christos

      2018-04-01

      Recent developments in the field of low-cost sensors enable the design and implementation of compact, inexpensive and portable sensing units for air pollution monitoring with fine-detailed spatial and temporal resolution, in order to support applications of wider interest in the area of intelligent transportation systems (ITS). In this context, the present work advances the concept of developing a low-cost portable air pollution monitoring system (APMS) for measuring the concentrations of particulate matter (PM), in particular fine particles with a diameter of 2.5 μm or less (PM2.5). Specifically, this paper presents the on-field testing of the proposed low-cost APMS implementation using roadside measurements from a mobile laboratory equipped with a calibrated instrument as the basis of comparison and showcases its accuracy on characterizing the PM2.5 concentrations on 1 min resolution in an on-road trial. Moreover, it demonstrates the intended application of collecting fine-grained spatio-temporal PM2.5 profiles by mounting the developed APMS on an electric bike as a case study in the city of Mons, Belgium.

    13. Farklı Tip Türk Rakılarında Temel Uçucu Bileşiklerin Gaz Kromatografisinde Doğrudan Enjeksiyonla Belirlenmesi

      Directory of Open Access Journals (Sweden)

      Seda Özkandan

      2015-02-01

      Full Text Available Bu çalışmada, tek üzüm çeşidinden (Misket, yaş üzümden ve kuru üzüm suması melas alkolü karışımından üretilen farklı tipteki rakıların bileşimleri ve temel uçucu bileşikleri araştırılmıştır. Metanol ve temel uçucu bileşikler (asetaldehit, asetal, metil asetat, etil asetat, 2-bütanol, n-propanol, izobütanol, n-bütanol, aktif amil alkol, izoamil alkol, trans anetol ve estragol AB referans yöntemine göre GC- FID ile belirlenmiştir. Rakıların temel uçucu bileşiklerini, sırasıyla, anason kaynaklı trans anetol ve suma kaynaklı yüksek alkoller, esterler, aldehitler ve uçucu asitler oluşturmuştur. Rakılarda, toplam uçucu madde miktarları uçar asit dahil, 124.99-163.40 g/hL mA arasında, trans anetol miktarları 1038-1380 mg/L arasında, metanol miktarları 43.96-56.91 g/hL mA arasında değişmiştir. En yüksek toplam uçucu madde miktarı Misket üzümünden elde edilen rakıda bulunmuştur. Tek çeşitten ve yaş üzümden üretilen rakıların, karışımdan üretilen rakılara göre daha yüksek miktarlarda toplam uçucu madde ve özellikle yüksek alkoller içerdikleri belirlenmiştir. Yüksek alkol miktarları bakımından tipler arasındaki fark önemli bulunmuştur (P<0.05. Trans anetol miktarı en yüksek yaş üzüm rakısında, en düşük misket rakısında belirlenmiştir. Öte yandan, genel olarak rakıların bileşimlerinin TGK Distile Alkollü İçkiler Tebliği’ne uygun oldukları saptanmıştır.

    14. Jung Işığında Heba Heba In The Light Of Jung

      Directory of Open Access Journals (Sweden)

      Esra SAZYEK

      2013-09-01

      Full Text Available Hasan Ali Toptaş, is one of the important authors of Turkishliterature, in his novel called Heba discusses inward looking personalityof Ziya, who lives in the same childish purity during his life consistingof all periods of childhood, military service, marriage and death. Due tothis property, he lives world of dreams and fantasies rather than reeltime. 16 years after he lost his wife and unborn son as casualties inbomb attack, Yazıköy where he breaks away from the crowd of the cityand settle in here, feeds his this side. Thus, the hours passing in thenature, turn into a worship. However, whole peace of Ziya, who hasfound what he seeks in Yazıköy, ends by killing of Kenan. This periodwhen everything has became complicated, is followed by killing of himas being lynched because of the gossips about him.When you reread the novel focusing on a wasted life, of whichtragic events are finished by death in the light of Jungian psychology, itturns into a story of award to reach immortality obtained after thesorrows felt.Experiences of Ziya in Yazıköy resembling Heaven until he isdismissed, realize on the cusp of a magical environment is surroundedby dreams and fantasies. Appearance of unconscious plane by means ofsymbolical contents in dreams indicates that Yazıköy representsunconscious world beyond being a geographic and travelling from thecity to natural follows a way from conscious towards unconscious.Exploring of Ziya moving in unknown darkness of unconsciousthe inner treasure in the deepest, requires passing the each phase fromsurface towards center with a different figure of unconscious named as"archetype" by Jung.In this study, dimensions of period in question will be discussedin terms of Jungian psychology; trails of his thoughts will be examinedin detail by its aspects are reflected on contextual dimension of thenovel. Türk edebiyatının önemli yazarlarından olan Hasan Ali Toptaş, Heba adlı romanında çocukluk, askerlik, evlilik

    15. The next generation borescope -- Video imaging measurement systems as portable as a fiberscope

      International Nuclear Information System (INIS)

      Boyd, C.E.

      1994-01-01

      Today, Remote Visual Inspection (RVI) techniques routinely save industry the significant costs associated with unscheduled shutdowns and equipment disassembly by enabling visual inspection of otherwise inaccessible equipment surfaces with instruments called borescopes. Specific applications in the nuclear industry include heat exchangers, condensers, boiler tubes, steam generators, headers, and other general interior surface inspections. While borescope inspections have achieved widespread utility, their potential applicability and value have been limited by their inability to provide dimensional information about the objects seen. This paper presents a simple, but very accurate measurement technique that enables the inspector to make measurements of objects directly from the borescope image. While used effectively since 1990, the technique is designed for a video imaging borescope and has, therefore, not been available for the shorter length fiberscope applications--until now. On June 6, 1993 Welch Allyn introduced the VideoProbe XL, a video imaging borescope that is as portable and affordable as a one meter fiberscope. This breakthrough not only extends video imaging into the rest of the fiberscope world, but opens the door for them to this measurement capability as well

    16. Field uses of a portable 4/6 MeV electron linear accelerator

      International Nuclear Information System (INIS)

      Schonberg, R.G.

      1987-01-01

      The portable electron linear accelerator which was developed on Electric Power Research Institute funds was targeted to provide an additional inspection tool for the nuclear power industry. The results have justified the expense in cost savings by reducing unnecessary repairs and in demonstrating integrity of some critical welds in pump bodies. The minac (miniature accelerator) has proven effective in cases where other inspection techniques have been ineffective, such as cast stainless steel pump bodies and overlay clad welds. Other applications, such as dynamic imaging of rocket motor test firings and field inspection of pressure vessels, will be reported. A description of the equipment, the method of field operation and the special safety problems related to a high intensity radiation source without containment will be discussed. (orig.)

    17. Portable FAIMS: Applications and Future Perspectives.

      Science.gov (United States)

      Costanzo, Michael T; Boock, Jared J; Kemperman, Robin H J; Wei, Michael S; Beekman, Christopher R; Yost, Richard A

      2017-11-01

      Miniaturized mass spectrometry (MMS) is optimal for a wide variety of applications that benefit from field-portable instrumentation. Like MMS, field asymmetric ion mobility spectrometry (FAIMS) has proven capable of providing in situ analysis, allowing researchers to bring the lab to the sample. FAIMS compliments MMS very well, but has the added benefit of operating at atmospheric pressure, unlike MS. This distinct advantage makes FAIMS uniquely suited for portability. Since its inception, FAIMS has been envisioned as a field-portable device, as it affords less expense and greater simplicity than many similar methods. Ideally, these are simple, robust devices that may be operated by non-professional personnel, yet still provide adequate data when in the field. While reducing the size and complexity tends to bring with it a loss of performance and accuracy, this is made up for by the incredibly high throughput and overall convenience of the instrument. Moreover, the FAIMS device used in the field can be brought back to the lab, and coupled to a conventional mass spectrometer to provide any necessary method development and compound validation. This work discusses the various considerations, uses, and applications for portable FAIMS instrumentation, and how the future of each applicable field may benefit from the development and acceptance of such a device.

    18. 14 CFR 91.21 - Portable electronic devices.

      Science.gov (United States)

      2010-01-01

      ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...

    19. Lessons learned in testing of Safeguards equipment

      International Nuclear Information System (INIS)

      Pepper, Susan; Farnitano, Michael; Carelli, Joseph

      2001-01-01

      Full text: During the 1990s, the IAEA Department of Safeguards began a transition from analog to digital equipment. This included surveillance equipment, seals, NDA measurement systems, and other instruments. The transition to digital equipment was intended to facilitate compatibility between and integration of instruments, remote communication of data, improved data storage, and modernization. Many of the instruments are designed to operate on battery power during loss of facility power, and therefore, are designed to consume minimal power. In 2000, the IAEA experienced a number of failures in digital image surveillance (DIS) equipment. A study of the performance data revealed that the failures occurred in 'high risk' environments where the systems were exposed to neutrons. As a supporter of IAEA equipment development and implementation, the U.S. Support Program worked with the IAEA, the equipment designer, and the equipment manufacturer in special meetings on DIS to determine the cause of the failures. It was as a result of these meetings that single event upset (SEU) was determined to be the root cause of the failures. The meeting participants also identified a list of actions to improve the reliability of DIS systems. As a result of the DIS meetings and the identified actions, the U.S. Support Program approved a request from the IAEA and established Task E.125, 'Remote Monitoring and Unattended Digital Surveillance Systems.' This task is an umbrella task intended to provide a mechanism for response to IAEA needs related to improving the reliability of unattended, remote monitoring and DIS equipment. Subtasks approved under this task include: E.125.1, 'SDIS Software Consolidation and DCM-14 Audit' - This subtask involves the consolidation of a number of individual upgrades to the SDIS and review of the DCM-14 software. As the sponsor of the design of the DCM-14 by Dr. Neumann, the German Support Program is also a participant in this subtask; E.125.2, 'DIS

    20. Oil leakage detection for electric power equipment based on ultraviolet fluorescence effect

      Science.gov (United States)

      Zhang, Jing; Wang, Jian-hui; Xu, Bin; Huang, Zhi-dong; Huang, Lan-tao

      2018-03-01

      This paper presents a method to detect the oil leakage of high voltage power equipment based on ultraviolet fluorescence effect. The method exploits the principle that the insulating oil has the fluorescent effect under the irradiation of specific ultraviolet light. The emission spectrum of insulating oil under excitation light with different wavelengths is measured and analyzed first. On this basis, a portable oil leakage detective device for high voltage power equipment is designed and developed with a selected 365 nm ultraviolet as the excitation light and the low light level camera as the fluorescence image collector. Then, the feasibility of the proposed method and device in different conditions is experimentally verified in the laboratory environment. Finally, the developed oil leakage detective device is applied to 500 kV Xiamen substation and Quanzhou substation. And the results show that the device can detect the oil leakage of high voltage electrical equipment quickly and conveniently even under the condition of a slight oil leakage especially in the low light environment.

    1. Use of smartphones and portable media devices for quantifying human movement characteristics of gait, tendon reflex response, and Parkinson's disease hand tremor.

      Science.gov (United States)

      LeMoyne, Robert; Mastroianni, Timothy

      2015-01-01

      Smartphones and portable media devices are both equipped with sensor components, such as accelerometers. A software application enables these devices to function as a robust wireless accelerometer platform. The recorded accelerometer waveform can be transmitted wireless as an e-mail attachment through connectivity to the Internet. The implication of such devices as a wireless accelerometer platform is the experimental and post-processing locations can be placed anywhere in the world. Gait was quantified by mounting a smartphone or portable media device proximal to the lateral malleolus of the ankle joint. Attributes of the gait cycle were quantified with a considerable accuracy and reliability. The patellar tendon reflex response was quantified by using the device in tandem with a potential energy impact pendulum to evoke the patellar tendon reflex. The acceleration waveform maximum acceleration feature of the reflex response displayed considerable accuracy and reliability. By mounting the smartphone or portable media device to the dorsum of the hand through a glove, Parkinson's disease hand tremor was quantified and contrasted with significance to a non-Parkinson's disease steady hand control. With the methods advocated in this chapter, any aspect of human movement may be quantified through smartphones or portable media devices and post-processed anywhere in the world. These wearable devices are anticipated to substantially impact the biomedical and healthcare industry.

    2. Portability of Technical Skills Across Occupations

      OpenAIRE

      Mukuni, Joseph Siloka

      2012-01-01

      In the literature, much has been reported about skill shortages in the labor market and many solutions have been suggested but most of them do not appear to work well for developing countries. This study investigated the place of portable technical skills as an option for addressing skill shortages, particularly in developing countries. The objective of the study was to determine whether different occupations have portable technical skills, which graduates of workforce development programs ca...

    3. Portability of supplementary pension rights in Europe

      DEFF Research Database (Denmark)

      Guardiancich, Igor

      2015-01-01

      In its effort to guarantee the free movement of workers, the European Union devised an advanced system of coordination of social security rights. Since 1958, statutory pensions are being aggregated for workers moving across the Member States. However, until mid-2014, the portability of supplement......In its effort to guarantee the free movement of workers, the European Union devised an advanced system of coordination of social security rights. Since 1958, statutory pensions are being aggregated for workers moving across the Member States. However, until mid-2014, the portability...... of supplementary pension rights was not assured, there by undermining the freedom to labor mobility. This impaired the efficient allocation of labor, prevented sound family planning, infringed the fundamental right to social protection and during the Great Recession, hindered the employability of workers across......, as opposed to the coordination of statutory ones, has been neglected and contested for a long time. Second, it illustrates the shortcomings of a patchy coordination- without-portability regime. Third, it enumerates the characteristics of the Portability Directive passed by the European Parliament in April...

    4. Radiation protection instrumentation. Monitoring equipment. Atmospheric radioactive iodine in the environment

      International Nuclear Information System (INIS)

      1995-01-01

      This international standard applies to portable or installed equipment for the monitoring of radioactive iodine (such as I-131 or I-125) in air in the environment of nuclear installations during normal operation, during design basis events, and in emergency situations. The monitoring involves continuous sample trapping and, where adequate, automatic start of sampling. The document deals with radioactive iodine monitor design, testing procedures, and documentation. Appended tables refer to the reference and normal testing conditions, tests in normal testing conditions, tests during changes of the affecting quantities, and tests of changes in the air circuit. (P.A.)

    5. NDA technology for uranium resource evaluation. Progress report July 1-December 31, 1979

      International Nuclear Information System (INIS)

      Evans, M.L.

      1980-08-01

      This report describes work performed during the time period from July 1, 1979 to December 31, 1979, on the contract for Nondestructive Nuclear Analysis (NDA) Technology for Uranium Resource Evaluation in Group Q-1. Calculational effort was focused on improving the accuracy with which detector response function maps can be generated for subsequent enfolding with ONETRAN angular flux data. Experimental effort was highlighted by a field test of the prototype photoneutron logging probe at the Grand Junction DOE calibration facility. The probe demonstrated adequate durability in the field and sufficient sensitivity to uranium to function at competitive logging speeds

    6. EFSA NDA Panel (EFSA Panel on Dietetic Products, Nutrition and Allergies), 2014. Scientific Opinion on Dietary Reference Values for biotin

      DEFF Research Database (Denmark)

      Tetens, Inge

      2014-01-01

      Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies (NDA) derived Dietary Reference Values (DRVs) for biotin. Biotin is a water-soluble vitamin which serves as a co-factor for several carboxylases that play critical roles in the synthesis...

    7. Nef‛î Divanında Gönül Heart in the Dȋvȃn of Nef‛ȋ’

      Directory of Open Access Journals (Sweden)

      Münire Nurefşan KAPAL

      2012-09-01

      Full Text Available Heart is one of the most common subject which place at Turkish Classical Literature of poetry’s Divan. The concept not only of Classical Literature, but also Folk Literature and oral culture among the topics deal with a lot of culture. İf there are love and lover in the beyit, heart of the lover absolutely take place in the world of the word at the same time. The poet who lived in the first half of the seventeeth century and found fame as a teacher of ode Nef‛î has included the concepts and comparisons in his Dîvân. The word, there are more than in the ghazals. The poet who wrote poetry in general, for the Sultan and statesmen, using exaggerated and a style full of praise; but in his ghazals he writes classic ghazal style and tells as to be in love and enthusiastic words. In his Dîvân, there is no mystical maning of this word. Heart which deal with a variety of interest of the meaning is extased, in love and a mirror showing the beauty lover. In this article, detail definitions of heart concept with various sources will be analyzed together with meanings of words and evaluated by statistical methods. Gönül, klasik edebiyat şairlerinin, divanlarında en çok rastlanan ve işlenen konularından biridir. Kavram sedece klasik edebiyatın değil, halk edebiyatının ve sözlü kültür sahasının da çok işlediği konular arasındadır. Aşk ve âşıklık söz konusu olduğu zaman elbette âşığın gönlü de beyitlerin kelime dünyasında hemen yerini alır. Bu itibarla hangi klasik edebiyat şairinin divanına bakılsa, hemen hemen hepsinde gönül kavramına ait mecazlar ve mazmunlar bulunduğu görülür. XVII. yüzyılın ilk yarısında yaşamış ve bir kaside üstadı olarak şöhret bulmuş olan şair Nef‛î, divanında gönülle ilgili kavram ve benzetmelere yer vermiştir. Kelime, geçiş sıklığı itbariyle daha çok gazellerde yer alır. Kasidelerini genel olarak padişah ve devlet adamlarına ithafen yazan ve m

    8. Analysis of solar blocker through portable X-ray fluorescence

      International Nuclear Information System (INIS)

      Ferreira, Diego de Dio; Melquiades, Fabio Luiz; Appoloni, Carlos Roberto; Lopes, Fabio; Lonni, Audrey Stinghen G.; Oliveira, Frederico Minardi de; Duarte, Jose C.

      2009-01-01

      This paper estimates the concentration of TiO 2 by Energy Dispersion X-ray fluorescence (EDXRF) viewing t obtain the FPS due to the physical barrier in the composition of solar blockers, and identifies possible present metals in the samples. A portable EDXRF equipment was used and 27 commercial of different brands and solar protection factors were analysed. Also, three formulations (A, B and C) were prepared and measured estimated in FPS-30 using 5% or TiO 2 . The quantification was performed through calibration curves with 1% to 30% standards of TiO 2 . As result, it was possible to determine the contribution to physical protection in the FPS, associated to the Ti concentration present in some solar blocker samples available in the market. Also, it was possible to detect the presence of various metals in solar protectors, such as Fe, Zn, Br and Sr, and identify chemical elements which were not mentioned and their formulation as well

    9. Development of custom LCD based portable survey/contamination monitors

      International Nuclear Information System (INIS)

      Reddy, J.D.

      2010-01-01

      Equipments for carrying out radiation survey measurements for alpha, beta and gamma radiations have evolved considerably with the advancements in Electronics overtime. There are 2 major classes of portable instruments available from most manufacturers - (a) Analog indicator type (b) Direct digital readout type. Analog meters give a direct quantifying feel to radiation levels though they are not rich features nor they have smartness like a digital meter. Digital versions have advantages of direct readout numerically and configurable as per users requirements. To achieve best features of both the techniques a dual indicator type LCD module comprising of Analog indicating LCD segments and digital readout indicating 7 segments has been developed. This LCD comprising of LCD glass and its display driver has been deployed across various types of survey meters and contamination monitors manufactured by Nucleonix. This display now facilitates direct readout of dose rate/count rate in various units simultaneously in both analog LCD scale and direct digital indication. (author)

    10. Portable bathtub: technology for bed bath in bedridden patients.

      Science.gov (United States)

      Backes, Dirce Stein; Gomes, Carine Alves; Pereira, Simone Barbosa; Teles, Noelucy Ferreira; Backes, Marli Terezinha Stein

      2017-04-01

      determine the benefits of the Portable Bathtub as technology for bed bath in bedridden patients. qualitative research of exploratory-descriptive character, whose data were collected by means of 30 interviews with patients, family members and professionals directly involved in bed bath, carried out with Portable Bathtub, in bedridden patients of a medical clinic, from July to December 2015. from the data encoded by thematic content analysis resulted two categories: Portable Bathtub: from morphine to the patient's rekindled eyes; From mechanized practice to unique, transforming care. we concluded that the Portable Bathtub constitutes enhancing technology, as it enables clinical improvement of the patient's general condition and transcends traditional mechanized practices by the reach of advanced nursing care practices.

    11. Utilization and development of the portable prototype equipment of lang inhalation with radioactive aerosols

      International Nuclear Information System (INIS)

      Marroni, B.J.; Siegmann, W.

      1986-01-01

      The 99 Tc-Aerosol was obtaneid from coloidal substances using a new apparatus, the 'Aerogama'. This equipment uses a conventional nebulyzer, an O 2 source, a respiratory system with inspiratory/expiratory compartments that are connected by valves and tubes with a one way flow. The environment contaminations is minimal and the 140 KeV energy rays are attenuated in about 93%. It has high utility in nuclear medicine as diagnostic tool applied to some lung diseases. (Author) [pt

    12. Accuracy of portable devices in measuring peak cough flow

      International Nuclear Information System (INIS)

      Kulnik, Stefan Tino; Kalra, Lalit; MacBean, Victoria; Birring, Surinder Singh; Moxham, John; Rafferty, Gerrard Francis

      2015-01-01

      Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini–Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min −1 when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min −1 . The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable. (paper)

    13. Wireless sensors for predictive maintenance of rotating equipment in research reactors

      International Nuclear Information System (INIS)

      Hashemian, H.M.

      2011-01-01

      In 2008-2009, the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL) tested the potential of predictive or condition-based maintenance techniques to reduce maintenance costs, minimize the risk of catastrophic failures, and maximize system availability by attaching wireless-based sensors to selected rotating equipment at HFIR. Rotating equipment is an ideal 'test case' for the viability of integrated, online predictive maintenance strategies because motors, bearings, and shafts are ubiquitous in nuclear power plants and because the maintenance methods typically performed on rotating equipment today (such as portable or handheld vibration data collection equipment) are highly labor-intensive. The HFIR project achieved all five of its objectives: (1) to identify rotating machinery of the types used in research reactors and determine their operational characteristics, degradation mechanisms, and failure modes, (2) to establish a predictive maintenance program for rotating equipment in research reactors, (3) to identify wireless sensors that are suitable for predictive maintenance of rotating machinery and test them in a laboratory setting, (4) to establish the requirements and procedures to be followed when implementing wireless sensors for predictive maintenance in research reactors, and (5) to develop a conceptual design for a predictive maintenance system for research reactors based on wireless sensors. The project demonstrated that wireless sensors offer an effective method for monitoring key process conditions continuously and remotely, thereby enhancing the safety, reliability, and efficiency of the aging research reactor fleet.

    14. Skylab IMSS checklist application study for emergency medical care. [emergency medical care operations involving the use and operation of the portable ambulance module

      Science.gov (United States)

      Carl, J. G.; Furukawa, S.

      1975-01-01

      A manual is presented that provides basic technical documentation to support the operation and utilization of the Portable Ambulance Module (PAM) in the field. The PAM is designed to be used for emergency resuscitation and victim monitoring. The functions of all the controls, displays, and stowed equipment of the unit are defined. Supportive medical and physiological data in those areas directly related to the uses of the PAM unit are presented.

    15. Impact of Burst Buffer Architectures on Application Portability

      Energy Technology Data Exchange (ETDEWEB)

      Harms, Kevin [Argonne National Lab. (ANL), Argonne, IL (United States); Oral, H. Sarp [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Center for Computational Science; Atchley, Scott [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Center for Computational Science; Vazhkudai, Sudharshan S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Center for Computational Science

      2016-09-30

      The Oak Ridge and Argonne Leadership Computing Facilities are both receiving new systems under the Collaboration of Oak Ridge, Argonne, and Livermore (CORAL) program. Because they are both part of the INCITE program, applications need to be portable between these two facilities. However, the Summit and Aurora systems will be vastly different architectures, including their I/O subsystems. While both systems will have POSIX-compliant parallel file systems, their Burst Buffer technologies will be different. This difference may pose challenges to application portability between facilities. Application developers need to pay attention to specific burst buffer implementations to maximize code portability.

    16. Uncertainty analysis of NDA waste measurements using computer simulations

      International Nuclear Information System (INIS)

      Blackwood, L.G.; Harker, Y.D.; Yoon, W.Y.; Meachum, T.R.

      2000-01-01

      Uncertainty assessments for nondestructive radioassay (NDA) systems for nuclear waste are complicated by factors extraneous to the measurement systems themselves. Most notably, characteristics of the waste matrix (e.g., homogeneity) and radioactive source material (e.g., particle size distribution) can have great effects on measured mass values. Under these circumstances, characterizing the waste population is as important as understanding the measurement system in obtaining realistic uncertainty values. When extraneous waste characteristics affect measurement results, the uncertainty results are waste-type specific. The goal becomes to assess the expected bias and precision for the measurement of a randomly selected item from the waste population of interest. Standard propagation-of-errors methods for uncertainty analysis can be very difficult to implement in the presence of significant extraneous effects on the measurement system. An alternative approach that naturally includes the extraneous effects is as follows: (1) Draw a random sample of items from the population of interest; (2) Measure the items using the NDA system of interest; (3) Establish the true quantity being measured using a gold standard technique; and (4) Estimate bias by deriving a statistical regression model comparing the measurements on the system of interest to the gold standard values; similar regression techniques for modeling the standard deviation of the difference values gives the estimated precision. Actual implementation of this method is often impractical. For example, a true gold standard confirmation measurement may not exist. A more tractable implementation is obtained by developing numerical models for both the waste material and the measurement system. A random sample of simulated waste containers generated by the waste population model serves as input to the measurement system model. This approach has been developed and successfully applied to assessing the quantity of

    17. Portable bathtub: technology for bed bath in bedridden patients

      Directory of Open Access Journals (Sweden)

      Dirce Stein Backes

      Full Text Available ABSTRACT Objective: determine the benefits of the Portable Bathtub as technology for bed bath in bedridden patients. Method: qualitative research of exploratory-descriptive character, whose data were collected by means of 30 interviews with patients, family members and professionals directly involved in bed bath, carried out with Portable Bathtub, in bedridden patients of a medical clinic, from July to December 2015. Results: from the data encoded by thematic content analysis resulted two categories: Portable Bathtub: from morphine to the patient's rekindled eyes; From mechanized practice to unique, transforming care. Conclusion: we concluded that the Portable Bathtub constitutes enhancing technology, as it enables clinical improvement of the patient's general condition and transcends traditional mechanized practices by the reach of advanced nursing care practices.

    18. Thickness Measurement of V2O5 Nanometric Thin Films Using a Portable XRF

      Directory of Open Access Journals (Sweden)

      Fabio Lopes

      2016-01-01

      Full Text Available Nanometric thin films have always been chiefly used for decoration; however they are now being widely used as the basis of high technology. Among the various physical qualities that characterize them, the thickness strongly influences their properties. Thus, a new procedure is hereby proposed and developed for determining the thickness of V2O5 nanometric thin films deposited on the glass surface using Portable X-Ray Fluorescence (PXRF equipment and the attenuation of the radiation intensity Kα of calcium present in the glass. It is shown through the present paper that the radiation intensity of calcium Kα rays is proportional to film thickness in nanometric films of vanadium deposited on the glass surface.

    19. Portable dosimeter

      International Nuclear Information System (INIS)

      Buffa, A.; Caley, R.; Pfaff, K.

      1986-01-01

      A simple but very accurate portable dosimeter is described for indicating the intensity of ionizing radiation, comprising, as a unit: (a) a radiation-detection chamber having a pair of parallel, facing, electrically-conducting, radiation-permeable electrodes spaced from each other to define a volume for a gas which is ionized by the radiation when exposed thereto; (b) electric potential supply means connected across the electrodes for attracting the gas ions to the electrodes and transferring their charge to the electrodes; (c) detection circuit means connected across the electrodes and having at least one of high-frequency electromagnetic- and radiation-sensitive components for detecting the charge on the electrodes and indicating therefrom a representation of the intensity of the radiation; (d) radiation shield means surrounding the radiation-sensitive components of the detection circuit means for shielding the latter from the ionizing radiation; (e) electric shield means surrounding the sensitive components of the detection circuit means for shielding the latter from electromagnetic interference including any caused by the ionizing radiation; and (f) ion shield means potting the ion-sensitive components for shielding them from radiation-caused ambient ionization; whereby the entire dosimeter may be assembled as the unit and portably transported into various radiation sources

    20. Development of a Real-Time Microchip PCR System for Portable Plant Disease Diagnosis

      Science.gov (United States)

      Kim, Hyun Soo; Cifci, Osman S.; Vaughn-Diaz, Vanessa L.; Ma, Bo; Kim, Sungman; Abdel-Raziq, Haron; Ong, Kevin; Jo, Young-Ki; Gross, Dennis C.; Shim, Won-Bo; Han, Arum

      2013-01-01

      Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25×16×8 cm3 in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample. PMID:24349341

    1. Development of a real-time microchip PCR system for portable plant disease diagnosis.

      Directory of Open Access Journals (Sweden)

      Chiwan Koo

      Full Text Available Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25 × 16 × 8 cm(3 in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample.

    2. Portable smartphone based quantitative phase microscope

      Science.gov (United States)

      Meng, Xin; Tian, Xiaolin; Yu, Wei; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Liu, Cheng; Wang, Shouyu

      2018-01-01

      To realize portable device with high contrast imaging capability, we designed a quantitative phase microscope using transport of intensity equation method based on a smartphone. The whole system employs an objective and an eyepiece as imaging system and a cost-effective LED as illumination source. A 3-D printed cradle is used to align these components. Images of different focal planes are captured by manual focusing, followed by calculation of sample phase via a self-developed Android application. To validate its accuracy, we first tested the device by measuring a random phase plate with known phases, and then red blood cell smear, Pap smear, broad bean epidermis sections and monocot root were also measured to show its performance. Owing to its advantages as accuracy, high-contrast, cost-effective and portability, the portable smartphone based quantitative phase microscope is a promising tool which can be future adopted in remote healthcare and medical diagnosis.

    3. Portable instrumentation for quantitatively measuring radioactive surface contaminations, including 90Sr

      International Nuclear Information System (INIS)

      Brodzinski, R.L.

      1983-10-01

      In order to measure the effectiveness of decontamination efforts, a quantitative analysis of the radiocontamination is necessary, both before and after decontamination. Since it is desirable to release the decontaminated material for unrestricted use or disposal, the assay equipment must provide adequate sensitivity to measure the radioactivity at or below the release limit. In addition, the instrumentation must be capable of measuring all kinds of radiocontaminants including fission products, activation products, and transuranic materials. Finally, the survey instrumentation must be extremely versatile in order to assay the wide variety of contaminated surfaces in many environments, some of which may be extremely hostile or remote. This communication describes the development and application of portable instrumentation capable of quantitatively measuring most transuranics, activation products, and fission products, including 90 Sr, on almost any contaminated surface in nearly any location

    4. Portable Tablets in Science Museum Learning: Options and Obstacles

      Science.gov (United States)

      Gronemann, Sigurd Trolle

      2017-06-01

      Despite the increasing use of portable tablets in learning, their impact has received little attention in research. In five different projects, this media-ethnographic and design-based analysis of the use of portable tablets as a learning resource in science museums investigates how young people's learning with portable tablets matches the intentions of the museums. By applying media and information literacy (MIL) components as analytical dimensions, a pattern of discrepancies between young people's expectations, their actual learning and the museums' approaches to framing such learning is identified. It is argued that, paradoxically, museums' decisions to innovate by introducing new technologies, such as portable tablets, and new pedagogies to support them conflict with many young people's traditional ideas of museums and learning. The assessment of the implications of museums' integration of portable tablets indicates that in making pedagogical transformations to accommodate new technologies, museums risk opposing didactic intention if pedagogies do not sufficiently attend to young learners' systemic expectations to learning and to their expectations to the digital experience influenced by their leisure use.

    5. PorTL - a compact, portable TLD reader for environmental and personal dosimetry

      International Nuclear Information System (INIS)

      Deme, S.; Apathy, I.; Bodnar, L.; Csoke, A.; Feher, I.; Pazmandi, T.

      2005-01-01

      Thermoluminescent dosimeters (TLDs) are commonly used for environmental monitoring, for personal and medical dosimetry, for dosimetry in nuclear facilities, etc. Major advantages are their independence of the power supply, small dimension, sensitivity, good stability, wide measuring range, resistance to environmental changes and relatively low cost. The disadvantage is that the detector must be transported for evaluation to a laboratory equipped with a large, heavy and expensive TLD Reader operated by qualified personnel, which considerably increases the costs and delays results. To overcome this disadvantage, the KFKI Atomic Energy Research Institute (KFKI AEKI), in co-operation with BL Electronics (Hungary), has developed a new and unique TLD system containing a small, portable, battery powered and moderate-price reader for commercial use. This paper gives a detailed description and parameters of this system.(author)

    6. New portable monitor enhances the ability to evaluate heat exchanger performance

      International Nuclear Information System (INIS)

      O'Toole, W.; Lacy, J.R.; Karlovich, D.N.

      1992-01-01

      Corrosion and fouling problems in nuclear power plant service water systems have led to industry-wide concern. These problems can affect the ability of these important heat exchangers to remove design heat loads. In addition, a limited amount of permanently installed on-line instrumentation is available to monitor key heat transfer parameters. A new, computerized monitoring system has been developed that acquires and manipulates process data. This enables power plant personnel to evaluate the on-line performance of important cooling system heat exchangers. The equipment provides the capability to continuously monitor, graph, and record cooling and process heat transfer parameters. The computer hardware is in a portable cabinet on wheels, which can be easily rolled from exchanger to exchanger for monitoring. This new monitoring system is being used at Consolidated Edison Company of New York Inc.'s Indian Point 2 Nuclear Station. They are currently expanding their performance testing on service water system heat exchangers and other auxiliary components to include those units that have limited on-line instrumentation. The ability to use clamp on flow and temperature sensing devices is necessary for trending exchanger performance. With on-line testing capabilities it is possible to: evaluate the cleanliness of plant heat transfer surfaces; make judgments about biofouling or antiscalant programs; and determine when equipment needs to be shut down for inspection or cleaning This paper describes this state-of-the-art equipment in detail and its application at the Indian Point 2 Nuclear Station. 9 refs., 8 figs., 1 tab

    7. EFSA NDA Panel (EFSA Panel on Dietetic Products, Nutrition and Allergies), 2014. Scientific Opinion on Dietary Reference Values for pantothenic acid

      DEFF Research Database (Denmark)

      Tetens, Inge

      2014-01-01

      Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies (NDA) derived Dietary Reference Values (DRVs) for pantothenic acid. Pantothenic acid is a water-soluble vitamin, which is a component of coenzyme A (CoA) and acyl-carrier proteins. Pantothenic...

    8. Experience of joint use NDA instruments between Japan and IAEA in inspection fields

      International Nuclear Information System (INIS)

      Yoshii, Hiroshi; Aoki, Minoru; Shimizu, Toku

      1997-01-01

      In order to implement more effective and efficient safeguards scheme in Japan, Japan and IAEA established joint use program of NDA instruments which was commenced in 1989 from LEU fuel fabrication facilities. The joint use program was proposed by Science and Technology Agency (STA) in the 10th (1989) Joint Japan and IAEA Committee, and it was agreed. Subsequently, Japan and IAEA established working group of the joint use program, whose prepared necessary joint use procedures. Currently, the joint use program has been expanding to almost facilities in domestic, and has been contributing reduce the facility operator's burden for the for inspection activities. (author)

    9. THE NUCLEAR MATERIAL MEASUREMENT PROGRAM PLAN FOR GOSATOMNADZOR OF RUSSIA

      International Nuclear Information System (INIS)

      Bokov, Dmitry; Byers, Kenneth R.

      2003-01-01

      As the Russian State regulatory agency responsible for oversight of nuclear material control and accounting (MC and A), Gosatomnadzor of Russia determines the status of the MC and A programs at Russian facilites by testing the nuclear material inventory for accounting record accuracy. Currently, Gosatomnadzor is developing and implementing an approach to planning and conducting MC and A inspections using non-destructive assay (NDA) instruments that will provide for consistent application of MC and A measurement inspection objectives throughtout Russia. This Gosatomnadzor NDA Program Plan documents current NDA measurement capability in all regions of Gosatomnadzor; provides justification for upgrades to equipment, procedures and training; and defines the inspector-facility operator interface as it relates to NDA measurement equipment use. This plan covers a three-year measurement program cycle, but will be reviewed and updated annually to ensure that adequate inspection resources are available to meet the demands of the inspection schedule. This paper presents the elements of this plan and describes the process by which Gosatomnadzor ensures that its NDA instruments are effectively utilized, procedures are developed and certified, and inspection personnel are properly trained to provide assurance that Russian nuclear facilities are in compliance with Russian MC and A regulations.

    10. Portable abdomen radiography. Moving to thickness-based protocols

      International Nuclear Information System (INIS)

      Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A.

      2018-01-01

      Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

    11. Portable abdomen radiography. Moving to thickness-based protocols

      Energy Technology Data Exchange (ETDEWEB)

      Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A. [University of Chicago Medical Center, Department of Radiology, Chicago, IL (United States)

      2018-02-15

      Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

    12. Portable telepathology: methods and tools.

      Science.gov (United States)

      Alfaro, Luis; Roca, Ma José

      2008-07-15

      Telepathology is becoming easier to implement in most pathology departments. In fact e-mail image transmit can be done from almost any pathologist as a simplistic telepathology system. We tried to develop a way to improve capabilities of communication among pathologists with the idea that the system should be affordable for everybody. We took the premise that any pathology department would have microscopes and computers with Internet connection, and selected a few elements to convert them into a telepathology station. Needs were reduced to a camera to collect images, a universal microscope adapter for the camera, a device to connect the camera to the computer, and a software for the remote image transmit. We found out a microscope adapter (MaxView Plus) that allowed us connect almost any domestic digital camera to any microscope. The video out signal from the camera was sent to the computer through an Aver Media USB connector. At last, we selected a group of portable applications that were assembled into a USB memory device. Portable applications are computer programs that can be carried generally on USB flash drives, but also in any other portable device, and used on any (Windows) computer without installation. Besides, when unplugging the device, none of personal data is left behind. We selected open-source applications, and based the pathology image transmission to VLC Media Player due to its functionality as streaming server, portability and ease of use and configuration. Audio transmission was usually done through normal phone lines. We also employed alternative videoconferencing software, SightSpeed for bi-directional image transmission from microscopes, and conventional cameras allowing visual communication and also image transmit from gross pathology specimens. All these elements allowed us to install and use a telepathology system in a few minutes, fully prepared for real time image broadcast.

    13. Forensic Analysis of the Sony Playstation Portable

      Science.gov (United States)

      Conrad, Scott; Rodriguez, Carlos; Marberry, Chris; Craiger, Philip

      The Sony PlayStation Portable (PSP) is a popular portable gaming device with features such as wireless Internet access and image, music and movie playback. As with most systems built around a processor and storage, the PSP can be used for purposes other than it was originally intended - legal as well as illegal. This paper discusses the features of the PSP browser and suggests best practices for extracting digital evidence.

    14. Technical Evaluation Report 57: Portable Applications in Mobile Education

      Directory of Open Access Journals (Sweden)

      Jon Baggaley

      2006-09-01

      Full Text Available Portable software applications can be carried on a convenient storage medium such as a USB drive, and offer numerous benefits to mobile teachers and learner. The article illustrates the growing field of ‘portable apps’ in reviews of seven contrasting products. These represent the major categories of document editing, email maintenance, Internet browsing, instant messaging, file transfer, multimedia presentation, and anti-virus protection. Emphasis is placed on ways to use ‘portable apps’ to overcome the common problems of Internet usage during travel.

    15. A portable telemetry system for brain stimulation and neuronal activity recording in freely behaving small animals.

      Science.gov (United States)

      Ye, Xuesong; Wang, Peng; Liu, Jun; Zhang, Shaomin; Jiang, Jun; Wang, Qingbo; Chen, Weidong; Zheng, Xiaoxiang

      2008-09-30

      A portable multi-channel telemetry system which can be used for brain stimulation and neuronal activity recording in freely behaving small animals is described here. This system consists of three major components of headstage, backpack and portable Personal Digital Assistant (PDA). The headstage contains high precision instrument amplifiers with high input impedance. The backpack is comprised of two parts: (1) a main board (size: 36 mm x 22 mm x 3.5 mm and weight: 40 g with batteries, 20 g without), with current/voltage stimulator and special circuit suitable for neuronal activity recording and (2) and a bluetooth transceiver, with a high data transmission rate up to 70 kb/s, suitable for downloading stimulation commands and uploading acquired data. We recorded neuronal activities of the primary motor area of a freely behaving rat with 12-bit resolution at 12 k samples/s. The recorded data and analysis results showed that the system was successful by comparing with the commercial equipment Cerebus 128-Channel Data Acquisition System (Cyberkinetics Inc.). Using the PDA, we can control stimulation and recording. It provides a flexible method to do some research work in the circumstances where other approaches would be difficult or impossible.

    16. Hayvan Islahında Güncel Bir Yaklaşım: CRISPR/Cas9 Genom Modifikasyon Sistemi

      Directory of Open Access Journals (Sweden)

      Fatih Bilgi

      2016-12-01

      Full Text Available Genom modifikasyonları, verimin arttırılmasında ve hastalıklara karşı direncin kazandırılması konusunda önemli avantajlar sağlama potansiyeli içermektedir. Bireyin zaten sahip olduğu bir genin susturulmasını ya da ifade edilmesini sağlayan gen düzenlenmesi yöntemleri (gene editing çevreyi en az etkileyerek genetik yapının geliştirilmesi konusunda önemli olanaklar sağlamaktadır. Son zamanlarda yeni genetik düzenleme yöntemleri geliştirilmiştir. Bunlar ZFN (Zinc Finger Nuclease’ler, TALEN (Transcription Activator-like Effector Nuclease’ler ve CRISPR/Cas nükleaz sistemleridir. CRISPR/Cas sistemi yabancı genetik materyalleri yok etmek için RNA güdümlü nükleazları kullanan bir mikrobiyal immün sistem olup, bu sistemin günümüzde hayvanlarda basit ve etkili bir gen düzenleme mekanizması olarak kullanılabilme potansiyeli değerlendirilmektedir. Bu derlemede CRISPR/Cas9 sistemi ve hayvan ıslahında kullanılabilirliği özetlenmiştir.

    17. 47 CFR 87.47 - Application for a portable aircraft station license.

      Science.gov (United States)

      2010-10-01

      ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Application for a portable aircraft station... SPECIAL RADIO SERVICES AVIATION SERVICES Applications and Licenses § 87.47 Application for a portable aircraft station license. A person may apply for a portable aircraft radio station license if the need...

    18. Brief scales to assess physical activity and sedentary equipment in the home

      Directory of Open Access Journals (Sweden)

      Durant Nefertiti

      2010-01-01

      Full Text Available Abstract Background Sedentary behaviors such as TV viewing are associated with childhood obesity, while physical activity promotes healthy weight. The role of the home environment in shaping these behaviors among youth is poorly understood. The study purpose was to examine the reliability of brief parental proxy-report and adolescent self-report measures of electronic equipment and physical activity equipment in the home and to assess the construct validity of these scales by examining their relationship to physical activity, sedentary behavior, and weight status of children and adolescents. Methods Participants were adolescents (n = 189; mean age = 14.6, parents of adolescents (n = 171; mean age = 45.0, and parents of younger children (n = 116; parents mean age = 39.6; children's mean age = 8.3 who completed two surveys approximately one month apart. Measures included a 21-item electronic equipment scale (to assess sedentary behavior facilitators in the home, in the child or adolescent's bedroom, and portable electronics and a 14-item home physical activity equipment scale. Home environment factors were examined as correlates of children's and adolescents' physical activity, sedentary behavior, and weight status after adjusting for child age, sex, race/ethnicity, household income, and number of children in the home. Results Most scales had acceptable test-retest reliability (intraclass correlations were .54 - .92. Parent and adolescent reports were correlated. Electronic equipment in adolescents' bedrooms was positively related to sedentary behavior. Activity equipment in the home was inversely associated with television time in adolescents and children, and positively correlated with adolescents' physical activity. Children's BMI z-score was positively associated with having a television in their bedroom. Conclusions The measures of home electronic equipment and activity equipment were similarly reliable when reported by parents and by

    19. Portable wireless power transmission system for video capsule endoscopy.

      Science.gov (United States)

      Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu

      2014-10-01

      Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.

    20. A Portable Passive Physiotherapeutic Exoskeleton

      Directory of Open Access Journals (Sweden)

      Dasheek Naidu

      2012-10-01

      Full Text Available The public healthcare system in South Africa is in need of urgent attention in no small part because there has been an escalation in the number of stroke victims which could be due to the increase in hypertension in this urbanizing society. There is a growing need for physiotherapists and occupational therapists in the country, which is further hindered by the division between urban and rural areas. A possible solution is a portable passive physiotherapeutic exoskeleton device. The exoskeleton device has been formulated to encapsulate methodologies that enable the anthropomorphic integration between a biological and mechatronic limb. A physiotherapeutic mechanism was designed to be portable and adjustable, without limiting the spherical motion and workspace of the human arm. The exoskeleton was designed to be portable in the sense that it could be transported geographically. It is a complete device allowing for motion in the shoulder, elbow, wrist and hand joints. The inverse kinematics was solved iteratively via the Damped Least Squares (DLS method. The electronic and computer system allowed for professional personnel to either change an individual joint or a combination of joints angles via the kinematic models. A ramp PI controller was established to provide a smooth response to simulate the passive therapy motion.

    1. Privacy preservation and information security protection for patients' portable electronic health records.

      Science.gov (United States)

      Huang, Lu-Chou; Chu, Huei-Chung; Lien, Chung-Yueh; Hsiao, Chia-Hung; Kao, Tsair

      2009-09-01

      As patients face the possibility of copying and keeping their electronic health records (EHRs) through portable storage media, they will encounter new risks to the protection of their private information. In this study, we propose a method to preserve the privacy and security of patients' portable medical records in portable storage media to avoid any inappropriate or unintentional disclosure. Following HIPAA guidelines, the method is designed to protect, recover and verify patient's identifiers in portable EHRs. The results of this study show that our methods are effective in ensuring both information security and privacy preservation for patients through portable storage medium.

    2. Recent activities of the ESARDA working group on NDA

      International Nuclear Information System (INIS)

      Harry, R.J.S.

      1983-01-01

      The European Safeguards Research and Development Association, ESARDA, has one of the largest coordinated safeguards and development programs in the world. There are several working groups for specific R and D activities. One of these is the ''ESARDA Working Group on Techniques and Standards for non-Destructive Analysis''. The NDA working group has initiated the international project of the preparation of uranium oxide certified reference materials for the gamma spectrometric determination of the enrichment, which are made in a collaboration with the US NBS and the European Communities' Central Bureau for Nuclear Measurements, CBNM, at Geel. The possibility of a similar type of reference material for Pu isotopic abundance measurements is investigated at CBNM, and the pilot samples may become available for intercomparisons. Safeguards acceptability and users manual have been considered carefully. The working group has undertaken an intercomparison on the determination of plutonium isotopic ratios by gamma spectrometry, using NBS-SRM's-946, -947 and 948. A new exercise on 0,5 gram samples of seven different isotopic compositions samples will be executed under the name PIDIE (Plutonium Isotopic Determination Intercomparison Exercise)

    3. Cürufa Olan Bakır Kayıplarında Farklı Kroze Kullanımının Etkisi

      OpenAIRE

      RÜŞEN, Aydın

      2017-01-01

      Bakır işletmelerinde ergitme aşamasında cürufa olan bakır kayıpları sektördeki önemli problemlerdenbiridir. Bu çalışmada, Eti Bakır İşletmelerinden (EBİ) temin edilen flaş fırın cürufu ve flaş fırın matı eşitmiktarlarda alınarak farklı oranlarda kolemanit (2CaO·3B2O3·5H2O) ilavesi (%0, %2, %4 ve %6) ilekarıştırılıp alumina (Al2O3) krozelerde 1250oC’de ve azot atmosferi altında 2 saat boyunca ergitmedeneylerine tabi tutulmuştur. Böylece, alümina kroze (AK) kullanılan deneylerde cürufa olan bak...

    4. Design, construction and validation of a portable care system for the daily telerehabiliatation of gait.

      Science.gov (United States)

      Giansanti, Daniele; Morelli, Sandra; Maccioni, Giovanni; Brocco, Monica

      2013-10-01

      When designing a complete system of daily-telerehabilitation it should be borne in mind that properly designed methodologies should be furnished for patients to execute specific motion tasks and for care givers to assess the relevant parameters. Whether in hospital or at home, the system should feature two basic elements: (a) instrumented and walking aids or supports, (b) equipment for the assessment of parameters. Being gait the focus, the idea was to design, construct and validate - as an alternative to the complex and expensive instruments currently used - a simple, portable kit that may be easily interfaced/integrated with the most common mechanical tools used in motion rehabilitation (instrumented walkways, aids, supports), with feedback to both patient for self-monitoring and trainer/therapist (present or remote) for clinical reporting. The proposed system consists of: one step-counter, three couples of photo-emitter detectors, one central unit for collecting and processing the telemetrically transmitted data; a software interface on a dedicated PC and a network adapter. The system has been successfully validated in a clinical application on two groups of 16 subjects at the 1st and 2nd level of the Tinetti test. The degree of acceptance by subjects and care-givers was high. The system was also successfully compared with an Inertial Measurement Unit, a de facto standard. The portable kit can be used with different rehabilitation tools and different ground rugosity. The advantages are: (a) very low costs when compared with optoelectronic solutions and other portable solutions; (b) very high accuracy, also for subjects with imbalance problems; (c) good compatibility with any rehabilitative tool. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

    5. A portable Halbach magnet that can be opened and closed without force: the NMR-CUFF.

      Science.gov (United States)

      Windt, Carel W; Soltner, Helmut; van Dusschoten, Dagmar; Blümler, Peter

      2011-01-01

      Portable equipment for nuclear magnetic resonance (NMR) is becoming increasingly attractive for use in a variety of applications. One of the main scientific challenges in making NMR portable is the design of light-weight magnets that possess a strong and homogeneous field. Existing NMR magnets can provide such magnetic fields, but only for small samples or in small regions, or are rather heavy. Here we show a simple yet elegant concept for a Halbach-type permanent magnet ring, which can be opened and closed with minimal mechanical force. An analytical solution for an ideal Halbach magnet shows that the magnetic forces cancel if the structure is opened at an angle of 35.3° relative to its poles. A first prototype weighed only 3.1 kg, and provided a flux density of 0.57 T with a homogeneity better than 200 ppm over a spherical volume of 5mm in diameter without shimming. The force needed to close it was found to be about 20 N. As a demonstration, intact plants were imaged and water (xylem) flow measured. Magnets of this type (NMR-CUFF = Cut-open, Uniform, Force Free) are ideal for portable use and are eminently suited to investigate small or slender objects that are part of a larger or immobile whole, such as branches on a tree, growing fruit on a plant, or non-metallic tubing in industrial installations. This new concept in permanent-magnet design enables the construction of openable, yet strong and homogeneous magnets, which aside from use in NMR or MRI could also be of interest for applications in accelerators, motors, or magnetic bearings. Copyright © 2010 Elsevier Inc. All rights reserved.

    6. Mechanical design for positioning of GM detector for system of avian flu virus detection equipment

      International Nuclear Information System (INIS)

      Rahmat; Budi Santoso; Krismawan; Abdul Jalil

      2010-01-01

      Mechanical design for positioning of GM detector system has been done. It is used for avian flu detection equipment. The requirements for the design are to protect detection system against shock, portable, and easy to maintain. The mechanical system consists of connectors, cable assemblies, holders, casing, housing and detectors cover. The selected material should have small gamma radiation absorption property in order to give optimum counts for the detector. The design result should give a system that is easy to operate, cheap and easy to assemble. (author)

    7. Determining plutonium mass in spent fuel with non-destructive assay techniques - NGSU research overview and update on 6 NDA techniques

      Energy Technology Data Exchange (ETDEWEB)

      Tobin, Stephen J [Los Alamos National Laboratory; Conlin, Jeremy L [Los Alamos National Laboratory; Evans, Louise G [Los Alamos National Laboratory; Hu, Jianwei [Los Alamos National Laboratory; Blanc, Pauline C [Los Alamos National Laboratory; Lafleur, Adrienne M [Los Alamos National Laboratory; Menlove, Howard O [Los Alamos National Laboratory; Schear, Melissa A [Los Alamos National Laboratory; Swinhoe, Martyn T [Los Alamos National Laboratory; Croft, Stephen [Los Alamos National Laboratory; Fensin, Michael L [Los Alamos National Laboratory; Freeman, Corey R [Los Alamos National Laboratory; Koehler, William E [Los Alamos National Laboratory; Mozin, V [Los Alamos National Laboratory; Sandoval, N P [Los Alamos National Laboratory; Lee, T H [KAERI; Cambell, L W [PNNL; Cheatham, J R [ORNL; Gesh, C J [PNNL; Hunt, A [IDAHO STATE UNIV; Ludewigt, B A [LBNL; Smith, L E [PNNL; Sterbentz, J [INL

      2010-09-15

      This poster is one of two complementary posters. The Next Generation Safeguards Initiative (NGSI) of the U.S. DOE has initiated a multi-lab/university collaboration to quantify the plutonium (Pu) mass in, and detect the diversion of pins from, spent nuclear fuel assemblies with non-destructive assay (NDA). This research effort has the goal of quantifying the capability of 14 NDA techniques as well as training a future generation of safeguards practitioners. By November of 2010, we will be 1.5 years into the first phase (2.5 years) of work. This first phase involves primarily Monte Carlo modelling while the second phase (also 2.5 years) will focus on experimental work. The goal of phase one is to quantify the detection capability of the various techniques for the benefit of safeguard technology developers, regulators, and policy makers as well as to determine what integrated techniques merit experimental work, We are considering a wide range of possible technologies since our research horizon is longer term than the focus of most regulator bodies. The capability of all of the NDA techniques will be determined for a library of 64 17 x 17 PWR assemblies [burnups (15, 30, 45, 60 GWd/tU), initial enrichments (2, 3, 4, 5%) and cooling times (1, 5, 20, 80 years)]. The burnup and cooling time were simulated with each fuel pin being comprised of four radial regions. In this paper an overview of the purpose will be given as well as a technical update on the following 6 neutron techniques: {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Passive Neutron Albedo Reactivity, Self-Integration Neutron Resonance Densitometry. The technical update will quantify the anticipated performance of each technique for the 64 assemblies of the spent fuel library.

    8. Determining plutonium mass in spent fuel with non-destructive assay techniques - NGSI research overview and update on 6 NDA techniques

      International Nuclear Information System (INIS)

      Tobin, Stephen J.; Conlin, Jeremy L.; Evans, Louise G.; Hu, Kianwei; Blanc, P.C.; Lafleur, Am; Menlove, H.O.; Schear, M.A.; Swinhoe, M.T.; Croft, S.; Fensin, M.L.; Freeman, C.R.; Koehler, W.E.; Mozin, V.; Sandoval, N.P.; Lee, T.H.; Cambell, L.W.; Cheatham, J.R.; Gesh, C.J.; Hunt, A.; Ludewigt, B.A.; Smith, L.E.; Sterbentz, J.

      2010-01-01

      This poster is one of two complementary posters. The Next Generation Safeguards Initiative (NGSI) of the U.S. DOE has initiated a multi-lab/university collaboration to quantify the plutonium (Pu) mass in, and detect the diversion of pins from, spent nuclear fuel assemblies with non-destructive assay (NDA). This research effort has the goal of quantifying the capability of 14 NDA techniques as well as training a future generation of safeguards practitioners. By November of 2010, we will be 1.5 years into the first phase (2.5 years) of work. This first phase involves primarily Monte Carlo modelling while the second phase (also 2.5 years) will focus on experimental work. The goal of phase one is to quantify the detection capability of the various techniques for the benefit of safeguard technology developers, regulators, and policy makers as well as to determine what integrated techniques merit experimental work, We are considering a wide range of possible technologies since our research horizon is longer term than the focus of most regulator bodies. The capability of all of the NDA techniques will be determined for a library of 64 17 x 17 PWR assemblies (burnups (15, 30, 45, 60 GWd/tU), initial enrichments (2, 3, 4, 5%) and cooling times (1, 5, 20, 80 years)). The burnup and cooling time were simulated with each fuel pin being comprised of four radial regions. In this paper an overview of the purpose will be given as well as a technical update on the following 6 neutron techniques: 252 Cf Interrogation with Prompt Neutron Detection, Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Passive Neutron Albedo Reactivity, Self-Integration Neutron Resonance Densitometry. The technical update will quantify the anticipated performance of each technique for the 64 assemblies of the spent fuel library.

    9. Portable non-destructive assay methods for screening and segregation of radioactive waste

      International Nuclear Information System (INIS)

      Simpson, Alan; Jones, Stephanie; Clapham, Martin; Lucero, Randy

      2011-01-01

      Significant cost-savings and operational efficiency may be realised by performing rapid non-destructive classification of radioactive waste at or near its point of retrieval or generation. There is often a need to quickly categorize and segregate bulk containers (drums, crates etc.) into waste streams defined at various boundary levels (based on its radioactive hazard) in order to meet disposal regulations and consignor waste acceptance criteria. Recent improvements in gamma spectroscopy technologies have provided the capability to perform rapid in-situ analysis using portable and hand-held devices such as battery-operated medium and high resolution detectors including lanthanum halide and high purity germanium (HPGe). Instruments and technologies that were previously the domain of complex lab systems are now widely available as touch-screen 'off-the-shelf' units. Despite such advances, the task of waste stream screening and segregation remains a complex exercise requiring a detailed understanding of programmatic requirements and, in particular, the capability to ensure data quality when operating in the field. This is particularly so when surveying historical waste drums and crates containing heterogeneous debris of unknown composition. The most widely used portable assay method is based upon far-field High Resolution Gamma Spectroscopy (HRGS) assay using HPGe detectors together with a well engineered deployment cart (such as the PSC TechniCART TM technology). Hand-held Sodium Iodide (NaI) detectors are often also deployed and may also be used to supplement the HPGe measurements in locating hot spots. Portable neutron slab monitors may also be utilised in cases where gamma measurements alone are not suitable. Several case histories are discussed at various sites where this equipment has been used for in-situ characterization of debris waste, sludge, soil, high activity waste, depleted and enriched uranium, heat source and weapons grade plutonium, fission products

    10. A Portable Burn Pan for the Disposal of Excess Propellants

      Science.gov (United States)

      2016-06-01

      2013 - 06/01/2016 A Portable Burn Pan for the Disposal of Excess Propellants Michael Walsh USA CRREL USA CRREL 72 Lyme Road Hanover, NH 03755...Army Alaska XRF X-Ray Florescence vii ACKNOWLEDGEMENTS Project ER-201323, A Portable Burn Pan for the Disposal of Gun Propellants, was a very...contamination problem while allowing troops to train as they fight, we have developed a portable training device for burning excess gun propellants. 1.1

    11. Travma Sonrası Kesici Diş Kırıkları Yüzde Sabit İz kapsamında Değerlendirilmeli mi

      Directory of Open Access Journals (Sweden)

      Mehmet Hakan Özdemir

      2014-04-01

      Full Text Available Türk Ceza Kanununda tanımlanan yaralanma suçlarının adli tıp açısından değerlendirilmesinde kullanılan kriterlerden biri de yüzde sabit iz kavramıdır. Bu suçlarının adli tıp açısından değerlendirilmesinde kullanılan klavuzda, yüzde sabit iz; yüz sınırları içerisinde oluşan yaralanmanın “iyileştikten sonra gün ışığında veya iyi aydınlatılmış ortamda , insanlar arası sözel diyaloğ  mesafesinden (1-2 metre ilk bakışta belirgin bir şekilde fark edilme” durumu olarak değerlendirilmektedir. Dişler ağız içinde yer almakla birlikte aynı zamanda yüz sınırları içindedir. Dinlenme pozisyonunda anatomik olarak dudaklarımız birbirinden hafif açık durmaktadır. Bu konumda özellikle üst kesici dişlerimiz üst dudaktan 2 mm aşağıda görünür haldedir. Cinsiyet farklılıklarına bağlı olarak genç kadınlarda dinlenme pozisyonunda sadece üst kesici dişler görülürken, genç erkeklerde hafif olmakla birlikte alt kesici dişler de görülmektedir. Yaş ilerledikçe yer çekimi kuvvetine bağlı doku sarkmalarıyla tersi bir durum gözlemlenir. Yaş ilerledikçe kadınlarda üst kesici dişler çok az görülürken daha çok alt kesici dişler görülmekte, erkeklerde ise üst kesici dişler görülmeyip  daha belirgin olarak alt kesici dişler görülmektedir. Eğer üst solunum yollarında bir obstrüksiyon varsa, ağızdan nefes alındığı için dudaklar arası açıklık artmakta  ve kesici dişler daha çok görülmektedir.  İnsanlar günlük yaşamında dudakları tam kapalı kalmadığından konuşma, gülme gibi işlevleri sırasında da özellikle kesici dişler görünür pozisyonda olmakta, bu dişlerdeki kırıklar ve eksiklikler daha görünür hale gelmektedir. Yüzde sabit iz ya da yüzün daimi değişikliği kavramları; insanların iletişim kurma, toplum içinde bulunma-yer alma, kendini iyi hissetme anlamında yüzün özel önemi nedeniyle, Türk Ceza

    12. Performance test of a portable TLD system for accidental doses

      International Nuclear Information System (INIS)

      Mihelic, M.; Stuhec, M.; Mitic, D.; Vekic, B.; Miljanic, S.; Ban, R.

      2005-01-01

      Full text: A portable TLD measuring system was constructed at the J. Stefan Institute many years ago, motivated by the thread of a catastrophic nuclear event. It was designed for fast measurements in accidental dosimetry mainly for military and civil protection use. The system consists of a robust portable measuring unit built for measurements in field conditions, sized about 40 cm in diameter and weighting 5 kg. Dosimeters are based on CaF 2 :Mn ceramic tablets closed in water resistant plastic housings. In original design producer assured measuring range from cGy to kGy. Specially designed energy compensating filters are used to satisfy requirements for energy response from 0,1 to 3 MeV. Stability of readings is maintained with the temperature stabilized light source. Measuring time for manually driven heating-reading cycle of one dosimeter is about 30 sec. Many systems of the type with sets of dosimeters were stored unused for some years in depositories of different institutions. Modernization of equipment in last years raised questions of applicability of such measurement systems for contemporary needs. The system was thus tested in a secondary standards dosimetry laboratory for compliance with up to date requirements for accidental individual monitoring. Dosimeter characteristics as repeatability, linearity and directional response were of particular interest. As a result of the tests, technical improvements are suggested to extent systems measuring capabilities in order to meet new standards. Possibilities of its use in different fields of dosimetry are discussed, where quick in field measurements of high doses is required as for example in medicine or in civil protection motivated by the new threads of terrorist attacks. (author)

    13. Portable sensor for hazardous waste

      Energy Technology Data Exchange (ETDEWEB)

      Piper, L.G.; Fraser, M.E.; Davis, S.J. [Physical Sciences Inc., Andover, MA (United States)

      1995-10-01

      We are beginning the second phase of a three and a half year program designed to develop a portable monitor for sensitive hazardous waste detection. The ultimate goal of the program is to develop our concept to the prototype instrument level. Our monitor will be a compact, portable instrument that will allow real-time, in situ, monitoring of hazardous wastes. This instrument will be able to provide the means for rapid field screening of hazardous waste sites to map the areas of greatest contamination. Remediation efforts can then focus on these areas. Further, our instrument can show whether cleanup technologies are successful at reducing hazardous materials concentrations below regulated levels, and will provide feedback to allow changes in remediation operations, if necessary, to enhance their efficacy.

    14. Development and application of portable mobile gamma spectrometry system (PMGSS) for realtime online radiological assessment

      International Nuclear Information System (INIS)

      Patil, S.S.; Padmanabhan, N.; Sharma, R.; Singh, R.; Pradeepkumar, K.S.

      2008-01-01

      A state of art mobile monitoring system is a prime requirement to combat the challenging radiological situations. In the event of any radiological/nuclear Emergencies an effective, realistic methodology of radiological measurements is an asset. In this context, a highly sensitive real-time online mobile monitoring system having features and provision to display the important parameters will be an essential tool in the course of radiological impact assessment. This paper, describes the efforts that has been made towards providing a useful Portable Mobile Gamma Spectrometry System (PMGSS) and developing applications so as to enhance its usefulness in quick radiological impact assessment and to initiate the proper countermeasures during any Nuclear/Radiological emergency situation in public domain. The system uses a NaI(Tl) detector, a global positioning system (GPS) and a laptop PC for storage, analysis and graphical representation of the acquired data. PMGSS is a highly sensitive, portable and reliable radiation monitoring equipment with capability of qualitative and quick estimation of the radioisotopes. The system was used for the mobile radiological mapping of Bangalore and Mumbai city and demonstrated its capability for use in environmental radiation monitoring during any radiological emergency requirement the results of which are presented here. (abstract)

    15. Comparison of Portable and Bench-Top Spectrometers for Mid-Infrared Diffuse Reflectance Measurements of Soils.

      Science.gov (United States)

      Hutengs, Christopher; Ludwig, Bernard; Jung, András; Eisele, Andreas; Vohland, Michael

      2018-03-27

      Mid-infrared (MIR) spectroscopy has received widespread interest as a method to complement traditional soil analysis. Recently available portable MIR spectrometers additionally offer potential for on-site applications, given sufficient spectral data quality. We therefore tested the performance of the Agilent 4300 Handheld FTIR (DRIFT spectra) in comparison to a Bruker Tensor 27 bench-top instrument in terms of (i) spectral quality and measurement noise quantified by wavelet analysis; (ii) accuracy of partial least squares (PLS) calibrations for soil organic carbon (SOC), total nitrogen (N), pH, clay and sand content with a repeated cross-validation analysis; and (iii) key spectral regions for these soil properties identified with a Monte Carlo spectral variable selection approach. Measurements and multivariate calibrations with the handheld device were as good as or slightly better than Bruker equipped with a DRIFT accessory, but not as accurate as with directional hemispherical reflectance (DHR) data collected with an integrating sphere. Variations in noise did not markedly affect the accuracy of multivariate PLS calibrations. Identified key spectral regions for PLS calibrations provided a good match between Agilent and Bruker DHR data, especially for SOC and N. Our findings suggest that portable FTIR instruments are a viable alternative for MIR measurements in the laboratory and offer great potential for on-site applications.

    16. Turizm Ürünlerinin Pazarlanmasında Fiziksel Kanıt Stratejileri

      OpenAIRE

      Yıldırgan, Recep; Zengin, Burhanettin

      2014-01-01

      Hizmet sektöründe sunulan ürünler, çoğunlukla soyut özellik taşıdığından bu ürünlerin pazarlamasında bazı somut verilerden yararlanmak gerekmektedir. Turizm işletmeleri de ürünlerini daha etkin pazarlayabilmek için bünyelerindeki fiziksel şartları, mekan, dizayn, ışık, renk, logo, işaret simge, ve bunun gibi unsurlarla somut hale getirerek hedef kitlelerin beğenisine sunarlar. Turizm pazarlaması karması açısından fiziksel kanıt elemanı olarak adlandırılan bu unsurlar, müşterinin turisti...

    17. Portable Data Acquisition System Project

      Data.gov (United States)

      National Aeronautics and Space Administration — Armstrong researchers have developed a portable data acquisition system (PDAT) that can be easily transported and set up at remote locations to display and archive...

    18. RAM R-200 - A Portable Ruggedized Radiation Monitoring System

      International Nuclear Information System (INIS)

      Wengrowicz, U.; Mazor, T.; Assido, H.; Kadmon, Y.; Tirosh, D.; Shani, G.

      1999-01-01

      RAM R-200, a new generation of ruggedized portable radiation-monitoring systems, is presented. The system which is a result of interdisciplinary research, was developed at the NRCN in collaboration with Ben-Gurion University. It consists of RAM R-200 - a portable radiation meter, and a variety of external probes for wide range gamma radiation fields and beta-gamma contamination detection and measurement. The meter or each one of the external probes can be used as a portable system or a stand-alone radiation measurement station. All the system's components were specially designed to meet severe environmental conditions

    19. Portable wireless metering

      Energy Technology Data Exchange (ETDEWEB)

      DiPaola, L [Powtel Monitoring Systems, Inc., Ajax, ON (Canada)

      1996-12-31

      Portable meters were discussed as alternatives to standard billing meters for temporary installations. Current, voltage and power factor at a distribution station were measured to calculate kW and kVAR, using an easy to install product that communicates live readings directly to the existing billing system. A background of situations where temporary metering is a possible alternative to regular meters was presented. Use of electronic, clamp on Electronic Recording Ammeters (ERA) and their drawbacks were discussed. An improved temporary metering solution using FM radio transmission to deliver live data to a receiving device, the Eagle Series 3500, was introduced. Improvements over previous ERA systems were discussed, including accuracy, lack of batteries, immediate confirmation of functionality, current, voltage and power factor monitoring, direct feed to billing system, line crew savings, need for only a single unit at any given site, bi-directional power flow metering, independent report storage media, and a portable voltage and P.F. diagnostic tool. Details of trial applications at the Utopia distribution station west of Barrie, ON were presented. This technology was said to be still in the testing stage, but its flexibility and economy were sonsidered to be very promising for future application.

    20. Portable Decontamination and Sterilization System

      National Research Council Canada - National Science Library

      Bell, William; Smerjac, Suzanne; Smith, Bryan

      2004-01-01

      TDA Research, Inc., (TDA) is developing a portable system to generate chlorine dioxide, which can be used for biodecontamination of small items and to sterilize medical and dental instruments in austere environments...

    1. Detection of pigments of halophilic endoliths from gypsum: Raman portable instrument and European Space Agency's prototype analysis

      Science.gov (United States)

      Culka, Adam; Osterrothová, Kateřina; Hutchinson, Ian; Ingley, Richard; McHugh, Melissa; Oren, Aharon; Edwards, Howell G. M.; Jehlička, Jan

      2014-01-01

      A prototype instrument, under development at the University of Leicester, for the future European Space Agency (ESA) ExoMars mission, was used for the analysis of microbial pigments within a stratified gypsum crust from a hypersaline saltern evaporation pond at Eilat (Israel). Additionally, the same samples were analysed using a miniaturized Raman spectrometer, featuring the same 532 nm excitation. The differences in the position of the specific bands, attributed to carotenoid pigments from different coloured layers, were minor when analysed by the ESA prototype instrument; therefore, making it difficult to distinguish among the different pigments. The portable Delta Nu Advantage instrument allowed for the discrimination of microbial carotenoids from the orange/green and purple layers. The purpose of this study was to complement previous laboratory results with new data and experience with portable or handheld Raman systems, even with a dedicated prototype Raman system for the exploration of Mars. The latter is equipped with an excitation wavelength falling within the carotenoid polyene resonance region. The ESA prototype Raman instrument detected the carotenoid pigments (biomarkers) with ease, although further detailed distinctions among them were not achieved. PMID:25368354

    2. A Portable Dynamic Laser Speckle System for Sensing Long-Term Changes Caused by Treatments in Painting Conservation.

      Science.gov (United States)

      Pérez, Alberto J; González-Peña, Rolando J; Braga, Roberto; Perles, Ángel; Pérez-Marín, Eva; García-Diego, Fernando J

      2018-01-11

      Dynamic laser speckle (DLS) is used as a reliable sensor of activity for all types of materials. Traditional applications are based on high-rate captures (usually greater than 10 frames-per-second, fps). Even for drying processes in conservation treatments, where there is a high level of activity in the first moments after the application and slower activity after some minutes or hours, the process is based on the acquisition of images at a time rate that is the same in moments of high and low activity. In this work, we present an alternative approach to track the drying process of protective layers and other painting conservation processes that take a long time to reduce their levels of activity. We illuminate, using three different wavelength lasers, a temporary protector (cyclododecane) and a varnish, and monitor them using a low fps rate during long-term drying. The results are compared to the traditional method. This work also presents a monitoring method that uses portable equipment. The results present the feasibility of using the portable device and show the improved sensitivity of the dynamic laser speckle when sensing the long-term process for drying cyclododecane and varnish in conservation.

    3. Detection of pigments of halophilic endoliths from gypsum: Raman portable instrument and European Space Agency's prototype analysis.

      Science.gov (United States)

      Culka, Adam; Osterrothová, Kateřina; Hutchinson, Ian; Ingley, Richard; McHugh, Melissa; Oren, Aharon; Edwards, Howell G M; Jehlička, Jan

      2014-12-13

      A prototype instrument, under development at the University of Leicester, for the future European Space Agency (ESA) ExoMars mission, was used for the analysis of microbial pigments within a stratified gypsum crust from a hypersaline saltern evaporation pond at Eilat (Israel). Additionally, the same samples were analysed using a miniaturized Raman spectrometer, featuring the same 532 nm excitation. The differences in the position of the specific bands, attributed to carotenoid pigments from different coloured layers, were minor when analysed by the ESA prototype instrument; therefore, making it difficult to distinguish among the different pigments. The portable Delta Nu Advantage instrument allowed for the discrimination of microbial carotenoids from the orange/green and purple layers. The purpose of this study was to complement previous laboratory results with new data and experience with portable or handheld Raman systems, even with a dedicated prototype Raman system for the exploration of Mars. The latter is equipped with an excitation wavelength falling within the carotenoid polyene resonance region. The ESA prototype Raman instrument detected the carotenoid pigments (biomarkers) with ease, although further detailed distinctions among them were not achieved. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

    4. A Portable Dynamic Laser Speckle System for Sensing Long-Term Changes Caused by Treatments in Painting Conservation

      Science.gov (United States)

      Pérez, Alberto J.; Braga, Roberto; Perles, Ángel; Pérez–Marín, Eva; García-Diego, Fernando J.

      2018-01-01

      Dynamic laser speckle (DLS) is used as a reliable sensor of activity for all types of materials. Traditional applications are based on high-rate captures (usually greater than 10 frames-per-second, fps). Even for drying processes in conservation treatments, where there is a high level of activity in the first moments after the application and slower activity after some minutes or hours, the process is based on the acquisition of images at a time rate that is the same in moments of high and low activity. In this work, we present an alternative approach to track the drying process of protective layers and other painting conservation processes that take a long time to reduce their levels of activity. We illuminate, using three different wavelength lasers, a temporary protector (cyclododecane) and a varnish, and monitor them using a low fps rate during long-term drying. The results are compared to the traditional method. This work also presents a monitoring method that uses portable equipment. The results present the feasibility of using the portable device and show the improved sensitivity of the dynamic laser speckle when sensing the long-term process for drying cyclododecane and varnish in conservation. PMID:29324692

    5. Rapid monitoring of gaseous radionuclides using a portable spectrometer

      International Nuclear Information System (INIS)

      Chung, C.; Tsai, C.H.

      1995-01-01

      A field gamma ray spectrometer, consisting of a portable high purity germanium detector, portable multichannel analyser, and a notebook computer, was used to conduct in situ rapid scanning of radioactive Ar, Kr and Xe isotopes in the air around a nuclear facility. The portable gamma ray spectrometer was calibrated using Ar, Kr, and Xe radioisotopes, activated in a research reactor and released in a sealed chamber. The unit was further tested inside the reactor containment to monitor the concentration of 41 Ar. In a typical one hour field measurement, the detection limits for some rare gas radionuclides corresponded to dose rates around 0.1 nSv.h -1 , which is far less than the dose rate induced by derived air concentrations imposed by the authority. The dose rate due to ground level concentrations of gaseous radionuclides dispersed from a source, such a nuclear facility or nuclear test, can be monitored in a short period using the portable unit. (Author)

    6. Portable Thermoelectric Power Generator Coupled with Phase Change Material

      Directory of Open Access Journals (Sweden)

      Lim Chong C.

      2014-07-01

      Full Text Available Solar is the intermittent source of renewable energy and all thermal solar systems having a setback on non-functioning during the night and cloudy environment. This paper presents alternative solution for power generation using thermoelectric which is the direct conversion of temperature gradient of hot side and cold side of thermoelectric material to electric voltage. Phase change material with latent heat effect would help to prolong the temperature gradient across thermoelectric material for power generation. Besides, the concept of portability will enable different power source like solar, wasted heat from air conditioner, refrigerator, stove etc, i.e. to create temperature different on thermoelectric material for power generation. Furthermore, thermoelectric will generate direct current which is used by all the gadgets like Smartphone, tablet, laptop etc. The portable concept of renewable energy will encourage the direct usage of renewable energy for portable gadgets. The working principle and design of portable thermoelectric power generator coupled with phase change material is presented in this paper.

    7. Portable x-ray fluorescence spectrometer. Innovative technology summary report

      International Nuclear Information System (INIS)

      1998-12-01

      This report describes the application of portable X-ray fluorescence (XRF) spectrometry to characterize materials related to deactivation and decommissioning (D and D) of contaminated facilities. Two portable XRF instruments manufactured by TN Spectrace were used in a technology evaluation as part of the Large-Scale Demonstration Project (LSDP) held at the Chicago Pile-5 Research Reactor (CP-5) located at Argonne National Laboratory (ANL). The LSDP is sponsored by the US Department of Energy (DOE), Office of Science and Technology, Deactivation and Decommissioning Focus Are (DDFA). The objective of the LSDP is to demonstrate innovative technologies or technology applications potentially beneficial to the D and D of contaminated facilities. The portable XRF technology offers several potential benefits for rapid characterization of facility components and contaminants, including significant cost reduction, fast turnaround time,a nd virtually no secondary waste. Field work for the demonstration of the portable XRF technology was performed from August 28--September 3, 1996 and October 30--December 13, 1996

    8. Design of portable electrocardiogram device using DSO138

      Science.gov (United States)

      Abuzairi, Tomy; Matondang, Josef Stevanus; Purnamaningsih, Retno Wigajatri; Basari, Ratnasari, Anita

      2018-02-01

      Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.

    9. Potential biodefense model applications for portable chlorine dioxide gas production.

      Science.gov (United States)

      Stubblefield, Jeannie M; Newsome, Anthony L

      2015-01-01

      Development of decontamination methods and strategies to address potential infectious disease outbreaks and bioterrorism events are pertinent to this nation's biodefense strategies and general biosecurity. Chlorine dioxide (ClO2) gas has a history of use as a decontamination agent in response to an act of bioterrorism. However, the more widespread use of ClO2 gas to meet current and unforeseen decontamination needs has been hampered because the gas is too unstable for shipment and must be prepared at the application site. Newer technology allows for easy, onsite gas generation without the need for dedicated equipment, electricity, water, or personnel with advanced training. In a laboratory model system, 2 unique applications (personal protective equipment [PPE] and animal skin) were investigated in the context of potential development of decontamination protocols. Such protocols could serve to reduce human exposure to bacteria in a decontamination response effort. Chlorine dioxide gas was capable of reducing (2-7 logs of vegetative and spore-forming bacteria), and in some instances eliminating, culturable bacteria from difficult to clean areas on PPE facepieces. The gas was effective in eliminating naturally occurring bacteria on animal skin and also on skin inoculated with Bacillus spores. The culturable bacteria, including Bacillus spores, were eliminated in a time- and dose-dependent manner. Results of these studies suggested portable, easily used ClO2 gas generation systems have excellent potential for protocol development to contribute to biodefense strategies and decontamination responses to infectious disease outbreaks or other biothreat events.

    10. Managing Geothermal Exploratory Drilling Risks Drilling Geothermal Exploration and Delineation Wells with Small-Footprint Highly Portable Diamond Core Drills

      Science.gov (United States)

      Tuttle, J.; Listi, R.; Combs, J.; Welch, V.; Reilly, S.

      2012-12-01

      Small hydraulic core rigs are highly portable (truck or scow-mounted), and have recently been used for geothermal exploration in areas such as Nevada, California, the Caribbean Islands, Central and South America and elsewhere. Drilling with slim diameter core rod below 7,000' is common, with continuous core recovery providing native-state geological information to aid in identifying the resource characteristics and boundaries; this is a highly cost-effective process. Benefits associated with this innovative exploration and delineation technology includes the following: Low initial Capital Equipment Cost and consumables costs Small Footprint, reducing location and road construction, and cleanup costs Supporting drill rod (10'/3meter) and tools are relatively low weight and easily shipped Speed of Mobilization and rig up Reduced requirements for support equipment (cranes, backhoes, personnel, etc) Small mud systems and cementing requirements Continuous, simplified coring capability Depth ratings comparable to that of large rotary rigs (up to ~10,000'+) Remote/small-location accessible (flown into remote areas or shipped in overseas containers) Can be scow or truck-mounted This technical presentation's primary goal is to share the technology of utilizing small, highly portable hydraulic coring rigs to provide exploratory drilling (and in some cases, production drilling) for geothermal projects. Significant cost and operational benefits are possible for the Geothermal Operator, especially for those who are pursuing projects in remote locations or countries, or in areas that are either inaccessible or in which a small footprint is required. John D. Tuttle Sinclair Well Products jtuttle@sinclairwp.com

    11. [Design and application of portable rescue vehicle].

      Science.gov (United States)

      Guo, Ying; Qi, Huaying; Wang, Shen

      2017-12-01

      The disease of critically ill patients was with rapid changes, and at any time faced the risk of emergency. The current commonly used rescue vehicles were larger and bulky implementation, which were not conducive to the operation, therefore the design of a portable rescue vehicle was needed. This new type of rescue vehicle is multi-layer folding structure, with small footprint, large storage space, so a variety of first aid things can be classified and put, easy to be cleaned and disinfected. In the rescue process, the portable rescue vehicles can be placed in the required position; box of various emergency items can be found at a glance with easy access; the height of the infusion stand can adjust freely according to the user height; the rescue vehicle handle can be easy to pull and adjust accord with human body mechanics principle. The portable rescue vehicle facilitates the operation of medical staff, and is worthy of clinical application.

    12. European Food Safety Authority; Response to comments on the Scientific Opinion of the EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) on the scientific substantiation of a health claim related to beta-palmitate and increased calcium absorption pursuant to Article 14 of Regulation (EC

      DEFF Research Database (Denmark)

      Tetens, Inge

      Following a request from the European Commission, EFSA was asked to review the scientific comments received on the Scientific Opinion of the EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) on the scientific substantiation of a health claim related to beta-palmitate and increased...... calcium absorption pursuant to Article 14 of Regulation (EC) No 1924/2006. Comments submitted to EFSA via the European Commission Services originated from the applicant (IDACE). EFSA has reviewed the comments and shared them with the chair of the NDA Panel, Prof. Albert Flynn, and the chair of the NDA...

    13. A mechanical design for positioning of gm detector for system of avian flu virus detection equipment

      International Nuclear Information System (INIS)

      Rahmat; Budi Santoso; Krismawan; Abdul Jalil

      2010-01-01

      Mechanical design for positioning of GM detector system has been done. It is used for avian flu detection equipment. The requirements for the design are to protect detection system against shock, portable, and easy to maintain. The mechanical system consists of connectors, cable assemblies, holders, casing, housing and detectors cover. The selected material should have small gamma radiation absorption property in order to give optimum counts for the detector. The design result should give a system that is easy to operate, cheap and easy to assemble. (author)

    14. A Portable Piezoelectric Tactile Terminal for Braille Readers

      Directory of Open Access Journals (Sweden)

      Ramiro Velázquez

      2012-01-01

      Full Text Available This paper introduces a novel concept on reading assistive technologies for the blind: the TactoBook, a system that is able to translate entire electronic books (eBooks to Braille code and to reproduce them in portable electronic Braille terminals. The TactoBook consists of a computer-based translator that converts fast and automatically any eBook into Braille. The Braille version of the eBook is then encrypted as a file and stored in a USB memory drive which is later inserted and reproduced in a compact, lightweight, and highly-portable tactile terminal. In particular, this paper presents a piezoelectric ultrasonic actuation approach to design and implement such portable Braille terminal. Actuating mechanism, design concept, first prototype, and performance results are presented and discussed.

    15. Portable Applications in Mobile Education. Technical Evaluation Report 57

      Science.gov (United States)

      Baggaley, Jon

      2006-01-01

      Portable software applications can be carried on a convenient storage medium such as a USB drive, and offer numerous benefits to mobile teachers and learner. The article illustrates the growing field of "portable apps" in reviews of seven contrasting products. These represent the major categories of document editing, email maintenance,…

    16. Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry.

      Science.gov (United States)

      Yung, Yeni P; Wickramasinghe, Raveendra; Vaikkinen, Anu; Kauppila, Tiina J; Veryovkin, Igor V; Hanley, Luke

      2017-07-18

      A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization (APPI). The laser ablation atmospheric pressure photoionization (LAAPPI) and LDTD-APPI mass spectra of sage leaves (Salvia officinalis) using a field-deployable quadrupole ion trap MS display many similar ion peaks, as do the mass spectra of membrane grown biofilms of Pseudomonas aeruginosa. These results indicate that LDTD-APPI method should be useful for in-field sampling of plant and microbial communities, for example, by portable ambient MS. The feasibility of many portable MS applications is facilitated by the availability of relatively low cost, portable, battery-powered diode lasers. LDTD could also be coupled with plasma- or electrospray-based ionization for the analysis of a variety of solid samples.

    17. Portable optical-resolution photoacoustic microscopy for volumetric imaging of multiscale organisms.

      Science.gov (United States)

      Jin, Tian; Guo, Heng; Yao, Lei; Xie, Huikai; Jiang, Huabei; Xi, Lei

      2018-04-01

      Photoacoustic microscopy (PAM) provides a fundamentally new tool for a broad range of studies of biological structures and functions. However, the use of PAM has been largely limited to small vertebrates due to the large size/weight and the inconvenience of the equipment. Here, we describe a portable optical-resolution photoacoustic microscopy (pORPAM) system for 3-dimensional (3D) imaging of small-to-large rodents and humans with a high spatiotemporal resolution and a large field of view. We show extensive applications of pORPAM to multiscale animals including mice and rabbits. In addition, we image the 3D vascular networks of human lips, and demonstrate the feasibility of pORPAM to observe the recovery process of oral ulcer and cancer-associated capillary loops in human oral cavities. This technology is promising for broad biomedical studies from fundamental biology to clinical diseases. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

    18. Development and calibration of a portable detection device for in vivo measurement of high-energy photon emitters incorporated by humans

      International Nuclear Information System (INIS)

      Soares, A.B.; Arbach, M.N.; Lucena, E.A.; Dantas, A.L.A.; Dantas, B.M.

      2017-01-01

      This work presents the evaluation of the applicability and sensitivity of a portable detection device specially designed for in vivo measurement of high-energy photon emitters in the human body. The calibration was performed at the In-Vivo Monitoring Laboratory of the IRD. The equipment consists of a lead-collimated NaI (Tl) 3″ x 3″ scintillation detector assembled on a tripod. The detector and its compact associated electronics are connected via USB cable to a portable PC. Spectrum acquisition and analysis is controlled by specific commercially available software. The calibration was performed using a standard liquid source of 152 Eu contained in 3 L polyethylene bottles. The evaluation of the system is based on the estimation of the minimum committed effective doses associated to the minimum detectable activities, calculated using current biokinetic and dosimetric models available in the literature. The dose detection limits for selected radionuclides of interest in an emergency scenario have shown to be far below 1 mSv allowing the system to be useful in accident situations. (author)

    19. Development and calibration of a portable detection device for in vivo measurement of high-energy photon emitters incorporated by humans

      Energy Technology Data Exchange (ETDEWEB)

      Soares, A.B.; Arbach, M.N.; Lucena, E.A.; Dantas, A.L.A.; Dantas, B.M., E-mail: alexandrebaso@globo.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Monitoração Interna

      2017-07-01

      This work presents the evaluation of the applicability and sensitivity of a portable detection device specially designed for in vivo measurement of high-energy photon emitters in the human body. The calibration was performed at the In-Vivo Monitoring Laboratory of the IRD. The equipment consists of a lead-collimated NaI (Tl) 3″ x 3″ scintillation detector assembled on a tripod. The detector and its compact associated electronics are connected via USB cable to a portable PC. Spectrum acquisition and analysis is controlled by specific commercially available software. The calibration was performed using a standard liquid source of {sup 152}Eu contained in 3 L polyethylene bottles. The evaluation of the system is based on the estimation of the minimum committed effective doses associated to the minimum detectable activities, calculated using current biokinetic and dosimetric models available in the literature. The dose detection limits for selected radionuclides of interest in an emergency scenario have shown to be far below 1 mSv allowing the system to be useful in accident situations. (author)

    20. A mobile and portable trusted computing platform

      Directory of Open Access Journals (Sweden)

      Nepal Surya

      2011-01-01

      Full Text Available Abstract The mechanism of establishing trust in a computing platform is tightly coupled with the characteristics of a specific machine. This limits the portability and mobility of trust as demanded by many emerging applications that go beyond the organizational boundaries. In order to address this problem, we propose a mobile and portable trusted computing platform in a form of a USB device. First, we describe the design and implementation of the hardware and software architectures of the device. We then demonstrate the capabilities of the proposed device by developing a trusted application.

    1. Portable DMFC system with methanol sensor-less control

      Energy Technology Data Exchange (ETDEWEB)

      Chen, C.Y.; Liu, D.H.; Huang, C.L.; Chang, C.L. [Institute of Nuclear Energy Research (INER), No. 1000, Wunhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546 (China)

      2007-05-15

      This work develops a prototype 20 W portable DMFC by system integration of stack, condenser, methanol sensor-less control and start-up characteristics. The effects of these key components and control schemes on the performance are also discussed. To expedite the use of portable DMFC in electronic applications, the system utilizes a novel methanol sensor-less control method, providing improved fuel efficiency, durability, miniaturization and cost reduction. The operating characteristics of the DMFC stack are applied to control the fuel ejection time and period, enabling the system to continue operating even when the MEAs of the stack are deteriorated. The portable system is also designed with several features including water balance and quick start-up (in 5 min). Notably, the proposed system using methanol sensor-less control with injection of pure methanol can power the DVD player and notebook PC. The system specific energy and energy density following three days of operation are 362 Wh kg{sup -1} and 335 Wh L{sup -1}, respectively, which are better than those of lithium batteries ({proportional_to}150 Wh kg{sup -1} and {proportional_to}250 Wh L{sup -}). This good energy storage feature demonstrates that the portable DMFC is likely to be valuable in computer, communication and consumer electronic (3C) markets. (author)

    2. α-sealed transfer device and portable plastic film sealers

      International Nuclear Information System (INIS)

      Fu Zhujun; Shan Ruixia

      1990-04-01

      An α transfer device which can be operated remotely is presented. The device is able to perform sealed transfer of radioactive articles from a hot cell or shielded glove box to the outside and non-radioactive articles from the outside to a hot cell or shielded glove box by using bag sealing technology. The structure of the transfer device is simple. Its operation is safe and reliable. The sealing performance of the device is very good (for alpha). The use of this transfer device will greatly reduce α contamination of the building and creates a favourable condition for operating radioactive materials in an undivided area. The portable heat sealing device is also a necessary tool in bag sealing technology and α-sealed transfer. Two types of portable plastic film sealers have been developed. Their structure is simple. The operation of the portable plastic film sealers is easy. Their performance is also excellent. Both the α-sealed transfer device and portable plastic film sealers are very useful to the reprocessing plant of nuclear fuel

    3. Portable hyperspectral fluorescence imaging system for detection of biofilms on stainless steel surfaces

      Science.gov (United States)

      Jun, Won; Lee, Kangjin; Millner, Patricia; Sharma, Manan; Chao, Kuanglin; Kim, Moon S.

      2008-04-01

      A rapid nondestructive technology is needed to detect bacterial contamination on the surfaces of food processing equipment to reduce public health risks. A portable hyperspectral fluorescence imaging system was used to evaluate potential detection of microbial biofilm on stainless steel typically used in the manufacture of food processing equipment. Stainless steel coupons were immersed in bacterium cultures, such as E. coli, Pseudomonas pertucinogena, Erwinia chrysanthemi, and Listeria innocula. Following a 1-week exposure, biofilm formations were assessed using fluorescence imaging. In addition, the effects on biofilm formation from both tryptic soy broth (TSB) and M9 medium with casamino acids (M9C) were examined. TSB grown cells enhance biofilm production compared with M9C-grown cells. Hyperspectral fluorescence images of the biofilm samples, in response to ultraviolet-A (320 to 400 nm) excitation, were acquired from approximately 416 to 700 nm. Visual evaluation of individual images at emission peak wavelengths in the blue revealed the most contrast between biofilms and stainless steel coupons. Two-band ratios compared with the single-band images increased the contrast between the biofilm forming area and stainless steel coupon surfaces. The 444/588 nm ratio images exhibited the greatest contrast between the biofilm formations and stainless coupon surfaces.

    4. Developing an Affordable and Portable Control Systems Laboratory Kit with a Raspberry Pi

      Directory of Open Access Journals (Sweden)

      Rebecca M. Reck

      2016-07-01

      Full Text Available Instructional laboratories are common in engineering programs. Instructional laboratories should evolve with technology and support the changes in higher education, like the increased popularity of online courses. In this study, an affordable and portable laboratory kit was designed to replace the expensive on-campus equipment for two control systems courses. The complete kit costs under $135 and weighs under 0.68 kilograms. It is comprised of off-the-shelf components (e.g., Raspberry Pi, DC motor and 3D printed parts. The kit has two different configurations. The first (base configuration is a DC motor system with a position and speed sensor. The second configuration adds a Furuta inverted pendulum attachment with another position sensor. These configurations replicate most of the student learning outcomes for the two control systems courses for which they were designed.

    5. Portable technologies at the museum

      DEFF Research Database (Denmark)

      Svabo, Connie

      2011-01-01

      A topic of interest in contemporary museum studies is how digital technologies contribute to museum visitor experiences. Building on insights from media and technology studies that new media should be understood for how they overlap with old media, the article reports an ethnographic study...... of the intersections between the exhibition at a modern museum of natural history and three portable technologies – one of which is digital. Mobile phone cameras, exercise pamphlets and dress-up costumes link visitors with an exhibition, but they simultaneously shape this relation in their own specific directions....... This is shown by drawing on the concept of mediation as it is developed by philosopher Michel Serres and philosopher of technology Bruno Latour. The article is based on the Ph.D. thesis entitled “Portable Objects at the Museum”, defended at Roskilde University on 22 September 2010....

    6. Development of Portable Venturi Kiln for Agricultural Waste Utilization by Carbonization Process

      Science.gov (United States)

      Agustina, S. E.; Chasanah, N.; Eris, A. P.

      2018-05-01

      Many types of kiln or carbonization equipment have been developed, but most of them were designed for big capacity and some also having low performance. This research aims to develop kiln, especially portable metal kiln, which has higher performance, more environmental- friendly, and can be used for several kinds of biomass or agricultural waste (not exclusive for one kind of biomass) as feeding material. To improve the kiln performance, a venturi drum type of portable kiln has been designed with an optimum capacity of 12.45 kg coconut shells. Basic idea of those design is heat flow improvement causing by venturi effect. The performance test for coconut shell carbonization shows that the carbonization process takes about 60-90 minutes to produce average yields of 23.8%., and the highest temperature of the process was 441 °C. The optimum performance has been achieved in the 4th test, which was producing 24% yield of highest charcoal quality (represented by LHV) in 65 minutes process at average temperature level 485 °C. For pecan shell and palm shell, design modification has been done by adding 6 air inlet holes and 3 ignition column to get better performance. While operation procedure should be modified on loading and air supply, depending on each biomass characteristic. The result of performance test showed that carbonization process of pecan shell produce 17 % yield, and palm shell produce 15% yield. Based on Indonesian Standard (SNI), all charcoal produced in those carbonization has good quality level.

    7. The FORCE: A highly portable parallel programming language

      Science.gov (United States)

      Jordan, Harry F.; Benten, Muhammad S.; Alaghband, Gita; Jakob, Ruediger

      1989-01-01

      Here, it is explained why the FORCE parallel programming language is easily portable among six different shared-memory microprocessors, and how a two-level macro preprocessor makes it possible to hide low level machine dependencies and to build machine-independent high level constructs on top of them. These FORCE constructs make it possible to write portable parallel programs largely independent of the number of processes and the specific shared memory multiprocessor executing them.

    8. The FORCE - A highly portable parallel programming language

      Science.gov (United States)

      Jordan, Harry F.; Benten, Muhammad S.; Alaghband, Gita; Jakob, Ruediger

      1989-01-01

      This paper explains why the FORCE parallel programming language is easily portable among six different shared-memory multiprocessors, and how a two-level macro preprocessor makes it possible to hide low-level machine dependencies and to build machine-independent high-level constructs on top of them. These FORCE constructs make it possible to write portable parallel programs largely independent of the number of processes and the specific shared-memory multiprocessor executing them.

    9. The portability of the "Electronics Workbench" simulation software to China

      NARCIS (Netherlands)

      Collis, Betty; Zhi-Cheng, Dong

      1993-01-01

      This article discusses the portability of the Canadian-made simulation software package, "Electronic Workbench" package (EWB) to China. As part of a larger project investigating the portability of various educational software packages, the EWB package was used in electronics instruction in China and

    10. PORTABLE SOURCE OF RADIOACTIVITY

      Science.gov (United States)

      Goertz, R.C.; Ferguson, K.R.; Rylander, E.W.; Safranski, L.M.

      1959-06-16

      A portable source for radiogiaphy or radiotherapy is described. It consists of a Tl/sup 170/ or Co/sup 60/ source mounted in a rotatable tungsten alloy plug. The plug rotates within a brass body to positions of safety or exposure. Provision is made for reloading and carrying the device safely. (T.R.H.)

    11. Geçmişten Günümüze Edebiyat Ders Planlarında Ve Kitaplarında Yahya Kemal ve Şiirleri From The Past Till Present Day Yahya Kemal And His Poets In Literature Curriculums And Course Books

      Directory of Open Access Journals (Sweden)

      Tevfik SÜTÇÜ

      2013-07-01

      prepared within the framework of literature curriculums ofTurkish Language and Literature course. Türk Edebiyatının XX. yüzyılda yetiştirdiği önemli şairlerinden biri Yahya Kemal Beyatlı’dır. Yahya Kemal, yaşadığı dönemin siyasi, sosyal ve tarihî hadiselerinin içinde yer almasının yanında, Türk edebiyatı ile ilgili önemli ve dikkat çekici hassasiyetleri olan bir şairimizdir. Bütün bu özellikleri ile birlikte Yahya Kemal, Türk şairleri arasında meydana getirdiği eserleri ile Türk dilinin güzel şiir örneklerini vermiş bir şahsiyettir. O, şiirlerinde ele aldığı farklı temaların yanında, şiirlerini meydana getirirken kullandığı dil, biçim ve şekil özellikleri ile öne çıkmış ve şairin bu özelliği hemen her dönemin edebiyat araştırmacıları ve eleştirmenleri tarafından kabul ve teslim edilmiştir.Öğretim kurumlarımızda edebiyat derslerinde edebiyatın diğer türleri ile beraber şiirle ilgili estetik beğenilerin geliştirilmesi ve edebiyat bilgilerinin öğretilmesi hedeflenir. Ülkemizde 1924’ten itibaren okullarımızda bütün diğer ders programları ile beraber edebiyat programlarını yeniden düzenleme çalışmaları da başlar. Cumhuriyet döneminde edebiyat öğretimindeki yönelimlerden birisi, edebiyat derslerinde okutulacak metinlerin çağdaş sanatçıların eserlerinden seçilmesi gerektiği yönündedir. Bu itibarla öğrencilere okuduklarından zevk alması ve yaşayan dilin örnekleriyle karşılaştırılması yanında, bazı metinlerden hareketle edebiyattaki tür ve şekil bilgisine ait konuların öğretilmesi, kavratılması ve tanıtılması mümkün olacaktır. Bütün bu özelliklere sahip olan Yahya Kemal’in eserlerinin ve metinlerinin, okul ders kitaplarında hemen her zaman yer alması isabetli bir tercih olmuştur ve olacaktır.Bu makalede, hangi yıllardan itibaren ve hangi dönemlerde Yahya Kemal’in hangi eserlerinin yoğun olarak ders kitaplarında yer ald

    12. The development of portable equipment to study physical and chemical phases in natural waters

      International Nuclear Information System (INIS)

      Breward, N.; Peachey, D.

      1988-08-01

      A direct and relatively non-invasive method of measuring the speciation of dissolved metals in groundwaters has been developed. The equipment relies on a series of columns containing DAEA cellulose, cation exchange resin and anion exchange resin to extract sequentially and respectively colloids, cationic and anionic species. Organic colloids are eluted from the DAEA cellulose with dilute caustic soda while the inorganic colloids (Fe/Al oxyhydroxide phase) are stripped with dilute mineral acid. A further advantage of this scheme is the ability to concentrate the phases by at least a factor of ten. Applications to the groundwaters of the natural analogue sites currently under study by BGS will offer a means of validating thermodynamic databases used in modelling speciation of radionuclides such as uranium and thorium. (author)

    13. Portable Weather Intelligence for the Soldier

      National Research Council Canada - National Science Library

      Sauter, David

      2008-01-01

      Enhancements in computer hardware and software technology have allowed the development and porting of advanced environmental effects applications on highly portable lightweight computing devices. The U.S...

    14. Radioactive air emissions notice of construction use of a portable exhauster on single-shell tanks during salt well pumping; FINAL

      International Nuclear Information System (INIS)

      HOMAN, N.A.

      1999-01-01

      (LFL). Safety analyses indicate that the LFL might be exceeded in some tanks during certain postulated accident scenarios. Also, the potential for electrical (pump motor, heat tracing) and mechanical (equipment installation) spark sources exist. Therefore, because of the presence of ignition sources and the potential for release of flammable gases, active ventilation might be required in some SSTs to reduce the ''time at risk'' while salt well pumping. For this reason, portable exhausters will be installed as a precautionary measure and used when flammable gas concentrations exceed 25 percent of the LFL during salt well pumping

    15. Portable EMG devices, Biofeedback and Contingent Electrical Stimulation applications in Bruxism

      DEFF Research Database (Denmark)

      Castrillon, Eduardo

      Portable EMG devices, Biofeedback and Contingent Electrical Stimulation applications in Bruxism Eduardo Enrique, Castrillon Watanabe, DDS, MSc, PhD Section of Orofacial Pain and Jaw Function, Department of Dentistry, Aarhus University, Aarhus, Denmark; Scandinavian Center for Orofacial Neuroscience...... Summary: Bruxism is a parafunctional activity, which involves the masticatory muscles and probably it is as old as human mankind. Different methods such as portable EMG devices have been proposed to diagnose and understand the pathophysiology of bruxism. Biofeedback / contingent electrical stimulation...... characteristics make it complicated to assess bruxism using portable EMG devices. The possibility to assess bruxism like EMG activity on a portable device made it possible to use biofeedback and CES approaches in order to treat / manage bruxism. The available scientific information about CES effects on bruxism...

    16. Çocukluk Çağında Anogenıtal Verru ve Cinsel İstismar

      Directory of Open Access Journals (Sweden)

      Dua Sumeyra Demirkıran

      2014-04-01

      Full Text Available Çocuklarda anogenital bölgede cinsel yolla bulaşan hastalıkların varlığı cinsel istismarın delilidir. Human papilloma virüs (HPV yetişkinlerin %80 ini etkileyen, en sık görülen cinsel yolla geçen hastalık kabul edilmektedir. Bu virüsün oluşturduğu verrülerin çocuklarda görülmesi cinsel istismar kanısı oluşturmaktadır. Çalışmamızda anogonital verrü (AGV ile ilgili literatür derlemesi yaparak AGV'li çocuk olgularına adli tıp yönünden yaklaşım önerilerini sunmayı amaçladık. Yapılan çalışmalara göre HPV'nin cinsel istismar dışında farklı bulaş yollarının olduğu bilimsel olarak saptanmıştır. Bu nedenle AGV'li çocuklara yaklaşımda cinsel istismar ön yargısının kırılması gerektiği kanaati oluşmuştur. Çocukların ve ailelerin "cinsel istismar" psikolojisinden uzak tutulmalıdır. Bu olgulara multidisipliner yaklaşılarak bulaş yolu hakkında kanaat oluştuktan sonra adli olgu açısından değerlendirilmelidir. Anahtar kelimeler: anogenital verrü, bulaş yolları, cinsel istismar

    17. Comparison of Portable and Bench-Top Spectrometers for Mid-Infrared Diffuse Reflectance Measurements of Soils

      Directory of Open Access Journals (Sweden)

      Christopher Hutengs

      2018-03-01

      Full Text Available Mid-infrared (MIR spectroscopy has received widespread interest as a method to complement traditional soil analysis. Recently available portable MIR spectrometers additionally offer potential for on-site applications, given sufficient spectral data quality. We therefore tested the performance of the Agilent 4300 Handheld FTIR (DRIFT spectra in comparison to a Bruker Tensor 27 bench-top instrument in terms of (i spectral quality and measurement noise quantified by wavelet analysis; (ii accuracy of partial least squares (PLS calibrations for soil organic carbon (SOC, total nitrogen (N, pH, clay and sand content with a repeated cross-validation analysis; and (iii key spectral regions for these soil properties identified with a Monte Carlo spectral variable selection approach. Measurements and multivariate calibrations with the handheld device were as good as or slightly better than Bruker equipped with a DRIFT accessory, but not as accurate as with directional hemispherical reflectance (DHR data collected with an integrating sphere. Variations in noise did not markedly affect the accuracy of multivariate PLS calibrations. Identified key spectral regions for PLS calibrations provided a good match between Agilent and Bruker DHR data, especially for SOC and N. Our findings suggest that portable FTIR instruments are a viable alternative for MIR measurements in the laboratory and offer great potential for on-site applications.

    18. TWRS hydrogen mitigation portable standard hydrogen monitoring system platform design and fabrication engineering task plan

      International Nuclear Information System (INIS)

      Philipp, B.L.

      1997-01-01

      The primary function of portable gas monitoring is to quickly determine tank vapor space gas composition and gas release rate, and to detect gas release events. Characterization of the gas composition is needed for safety analysis. The lower flammability limit, as well as the peak burn temperature and pressure, are dependent upon the gas composition. If there is little or no knowledge about the gas composition, safety analysis utilize compositions that yield the worst case in a deflagration or detonation. This conservative approach to unknowns necessitates a significant increase in administrative and engineering costs. Knowledge of the true composition could lead to reductions in the assumptions and therefore contribute to a reduction in controls and work restrictions. Also, knowledge of the actual composition will be required information for the analysis that is needed to remove tanks from the Watch List. Similarly, the rate of generation and release of gases is required information for performing safety analysis, developing controls, designing equipment, and closing safety issues. To determine release rate, both the gas concentrations and the dome space ventilation rates (exhauster flow rate or passive dome/atmosphere exchange rate) are needed. Therefore, to quickly verify waste tank categorization or to provide additional characterization for tanks with installed gas monitoring, a temporary, portable standard hydrogen monitoring system is needed that can be used to measure gas compositions at both high and low sensitivities

    19. Optical grid alignment system for portable radiography and portable radiography apparatus incorporating same

      International Nuclear Information System (INIS)

      MacMahon, H.

      1993-01-01

      A grid alignment system is described for use in a portable radiographic apparatus for aligning x-ray film with an x-ray source within said portable radiographic apparatus, comprising: a grid cassette, movable relative to said x-ray source, including an x-ray film holding portion, an anti-scatter grid substantially fixed relative to said x-ray film holding portion and positioned between said x-ray film holding portion and said x-ray source, and a reflector element substantially fixed relative to said grid, said reflector element including a reflective surface for reflecting said incident light beam to produce a reflected light beam, and an imaging surface for producing images of said incident light beam and said reflected light beam, said images providing an indication of alignment between said grid cassette and said x-ray source; and a light beam projector substantially fixed relative to said x-ray source, said light-beam projector projecting said incident light beam upon said reflector element to provide said indication of alignment between said grid cassette and said x-ray source

    20. 30 CFR 77.811 - Movement of portable substations and transformers.

      Science.gov (United States)

      2010-07-01

      ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.811 Movement of portable substations...

    1. Smart and accurate state-of-charge indication in portable applications

      NARCIS (Netherlands)

      Pop, V.; Bergveld, H.J.; Notten, P.H.L.; Regtien, P.P.L.

      2005-01-01

      Accurate state-of-charge (SoC) and remaining run-time indication for portable devices is important for the user-convenience and to prolong the lifetime of batteries. However, the known methods of SoC indication in portable applications are not accurate enough under all practical conditions. The

    2. Smart and accurate State-of-Charge indication in Portable Applications

      NARCIS (Netherlands)

      Pop, V.; Bergveld, H.J.; Notten, P.H.L.; Regtien, Paulus P.L.

      2006-01-01

      Accurate state-of-charge (SoC) and remaining run-time indication for portable devices is important for the user-convenience and to prolong the lifetime of batteries. However, the known methods of SoC indication in portable applications are not accurate enough under all practical conditions. The

    3. Expanding portable B-WIM technology.

      Science.gov (United States)

      2011-06-28

      Advances in weigh-in-motion technology over the past 15 years have led to successful field application of a : commercial grade portable Bridge WIM system (B-WIM) in Europe. Under a previous UTCA Research : Project No. 07212, UTCA tested the state-of-...

    4. Ab initio quantum chemistry in parallel-portable tools and applications

      International Nuclear Information System (INIS)

      Harrison, R.J.; Shepard, R.; Kendall, R.A.

      1991-01-01

      In common with many of the computational sciences, ab initio chemistry faces computational constraints to which a partial solution is offered by the prospect of highly parallel computers. Ab initio codes are large and complex (O(10 5 ) lines of FORTRAN), representing a significant investment of communal effort. The often conflicting requirements of portability and efficiency have been successfully resolved on vector computers by reliance on matrix oriented kernels. This proves inadequate even upon closely-coupled shared-memory parallel machines. We examine the algorithms employed during a typical sequence of calculations. Then we investigate how efficient portable parallel implementations may be derived, including the complex multi-reference singles and doubles configuration interaction algorithm. A portable toolkit, modeled after the Intel iPSC and the ANL-ACRF PARMACS, is developed, using shared memory and TCP/IP sockets. The toolkit is used as an initial platform for programs portable between LANS, Crays and true distributed-memory MIMD machines. Timings are presented. 53 refs., 4 tabs

    5. Miniature multichannel analyzer for process monitoring

      International Nuclear Information System (INIS)

      Halbig, J.K.; Klosterbuer, S.F.; Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.; Wiig, L.G.; Ianakiev, K.D.

      1993-01-01

      A new, 4,000-channel analyzer has been developed for gamma-ray spectroscopy applications. A design philosophy of hardware and software building blocks has been combined with design goals of simplicity, compactness, portability, and reliability. The result is a miniature, modular multichannel analyzer (MMMCA), which offers solution to a variety of nondestructive assay (NDA) needs in many areas of general application, independent of computer platform or operating system. Detector-signal analog electronics, the bias supply, and batteries are included in the virtually pocket-size, low-power MMMCA unit. The MMMCA features digital setup and control, automated data reduction, and automated quality assurance. Areas of current NDA applications include on-line continuous (process) monitoring, process material holdup measurements, and field inspections

    6. STS-102 Onboard Photograph-The Payload Equipment Restraint System

      Science.gov (United States)

      2001-01-01

      In this Space Shuttle STS-102 mission image, the Payload Equipment Restraint System H-Strap is shown at the left side of the U.S. Laboratory hatch and behind Astronaut James D. Weatherbee, mission specialist. PERS is an integrated modular system of components designed to assist the crew of the International Space Station (ISS) in restraining and carrying necessary payload equipment and tools in a microgravity environment. The Operations Development Group, Flight Projects Directorate at the Marshall Space Flight Center (MSFC), while providing operation support to the ISS Materials Science Research Facility (MSRF), recognized the need for an on-orbit restraint system to facilitate control of lose objects, payloads, and tools. The PERS is the offspring of that need and it helps the ISS crew manage tools and rack components that would otherwise float away in the near-zero gravity environment aboard the Space Station. The system combines Kevlar straps, mesh pockets, Velcro and a variety of cornecting devices into a portable, adjustable system. The system includes the Single Strap, the H-Strap, the Belly Pack, the Laptop Restraint Belt, and the Tool Page Case. The Single Strap and the H-Strap were flown on this mission. The PERS concept was developed by industrial design students at Auburn University and the MSFC Flight Projects Directorate.

    7. Geçmişten Günümüze Türk Polis Teşkilatında Rütbeler From Past To Present Police Ranks In Turkish National Police

      Directory of Open Access Journals (Sweden)

      Bülent AKKAYA

      2013-07-01

      Full Text Available Law enforcement (police as the Ottoman State and previousperiods was carried out by soldiers and other officials. Until it is calledinternal security service, military police units in carrying out this task.For this reason, the current sense, the police are not able to drive a veryold history. The use of present-day of the word police was in 1845 withthe establishment of the Turkish National Police.That rank highly with the word police, meaning owned degreesand position. Law enforcement the rank of staff education, successfuloperation, owned by a good record to take the title refers to thehierarchical profession. Policing is a career profession. Police officersmust be in a hierarchical structure. Of command within the policesystem degrees and ranks of police officers has to be a profession. Forthis reason, police ranks are quite important in a police organization.Many scientific studies are still being made about TurkishNational Police with the establishment and the development of it.However, historical developments of ranks in Turkish National Policehave not been revealed in a collective manner. In this study scanningthe police ranks of legislative texts, names, profession and evaluationwere performed. Police ranks like Police chief, the Commissioner camefrom Ottoman bureaucracy to Turkish Republic. These police ranksclasses in each other and show continuity with the texts of thelegislation. After giving information about police ranks which used inTurkish National Police, some useful assessments were made for today. Kolluk görevi Osmanlı Devleti ve daha önceki dönemlerde askerler ve diğer görevliler tarafından yerine getirilmiştir. İç güvenlik hizmetini yürüten birimlere polis adı verilene kadar asker kimseler tarafından bu görev yerine getirilmiştir. Bu nedenle bugünkü anlamda polis teşkilatı tarihini çok eskilere götürmek mümkün değildir. Polis kelimesinin günümüzdeki anlamında kullanılması ise 1845 yılında

    8. Development of a portable, high-energy radiographic source

      International Nuclear Information System (INIS)

      Reinhart, E.R.; Wenk, S.A.; Schonberg, R.G.; Mixon, G.L.

      1979-01-01

      The Electric Power Research Institute (EPRI) is sponsoring a two-year program to develop a portable, high-energy (3 to 4 MeV) radiographic system for inservice and repair inspections of components at nuclear power stations. The basic design concept uses a lightweight, portable linear accelerator (LINAC). The design objectives, concepts employed, and progress to date are described. Specific potential applications and accompanying radiographic techniques are discussed, along with the novel beam angulation devices to permit utilization in areas of highly restricted access

    9. Polisiye Roman Temsilcisi Ümit Deniz’in Romanlarında Cinayet Kurgusu The Murder Plot in The Novels of Umit Deniz

      Directory of Open Access Journals (Sweden)

      Nurullah ULUTAŞ

      2012-09-01

      Full Text Available Crime fiction, a genre that arose in modern times, deals with the social depression of the bourgeoisie class, which grew bigger in parallel with urbanization. In this genre, the social depression experienced by the modern individual is handled from a crime-centered point of view. The criminal is presented as an afflicted person who suffers from adaptation problems in society. The fact that murder takes a lot of space in these novels turns the concept of death into something ordinary in the minds of modern individuals. This style is carried into fiction through the richness of the rational analytical thinking in Western novels and attracts a large number of readers. The essential elements being mystery, intrigue, tension, crime and murder, the reader is kept alert and interested to follow the sequence of events. The aim of this study is to examine Umit Deniz’s method of creating a murder plot and in the light of the author’s seven novels to look into the psychological impact of murder on society. The techniques that the author makes use of in his writing process are also examined in order to shed light on the difference between crime fiction in Turkish Literature and crime fiction in the West. The main characters, murder plots, modern and traditional patterns, the use of inverted sentences, the fictional means that the author uses in order to keep the story flowing, are reviewed from a technical and theoritical point of view. The plot and any defects therein are criticized from a text-centered point of view. Modern zamanlara özgü bir tür olan polisiye roman, kentleşme ile gelişmeye başlayan burjuvazinin sosyal bunalımlarını suç merkezli olarak ele alır. Suçlunun topluma uyumsuz kişiler olarak yansıtıldığı bu romanlarda, cinayetlere fazla yer verilmesi, modern insan zihninde ölümün sıradanlaşmasına yol açar. Batı romanında rasyonel analitik düşünme zenginliği ile kurguya taşınan bu tarz, geniş okur

    10. Use of portable in motion weight control technologies at landfill sites

      CSIR Research Space (South Africa)

      Fisher, D

      2006-09-01

      Full Text Available Requirements for landfilling. In-motion weighing technology currently available in South Africa was investigated to assess its suitability as a 'portable landfill weighbridge'. The experience gained through testing the portable weighpad technology has indicated...

    11. 78 FR 34669 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

      Science.gov (United States)

      2013-06-10

      ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... importing wireless communication devices, portable music and data processing devices, and tablet computers... certain electronic devices, including wireless communication devices, portable music and data processing...

    12. Radioactive air emissions notice of construction portable/temporary radioactive air emission units - August 1998

      International Nuclear Information System (INIS)

      FRITZ, D.W.

      1999-01-01

      This notice of construction (NOC) requests a categorical approval for construction and operation of three types of portable/temporary radionuclide airborne emission units (PTRAEUs). These three types are portable ventilation-filter systems (Type I), mobile sample preparation facilities (Type II), and mobile sample screening and analysis facilities (Type III). Approval of the NOC application is intended to allow construction and operation of the three types of PTRAEUs without prior project-specific approval. Environmental cleanup efforts on the Hanford Site often require the use of PTRAEUs. The PTRAEUs support site characterization activities, expedited response actions (ERAs), sampling and monitoring activities, and other routine activities. The PTRAEUs operate at various locations around the Hanford Site. Radiation Air Emissions Program, Washington Administrative Code (WAC) 246-247, requires that the Washington State Department of Health (WDOH) be notified before construction of any new emission that would release airborne radioactivity. The WDOH also must receive notification before any modification of an existing source. This includes changes in the source term or replacement of emission control equipment that might significantly contribute to the offsite maximum dose from a licensed facility. During site characterization activities, ERAs, sampling and monitoring activities, and other routine activities, the PTRAEUs might require startup immediately. The notification period hampers efforts to complete such activities in an effective and timely manner. Additionally, notification is to be submitted to the WDOH when the PTRAEUs are turned off. The U.S. Department of Energy, Richland Operations Office (DOE-RL) potentially could generate several notifications monthly. The WDOH would be required to review and provide approval on each NOC as well as review the notices of discontinued sources. The WDOH regulation also allows facilities the opportunity to request a

    13. WRAP module 1 DMS/PCS interface definition document

      International Nuclear Information System (INIS)

      Weidert, J.R.

      1994-01-01

      This document has been developed to define the computer software interfaces between Waste Receiving ampersand Processing Module 1 (WRAP 1) computer systems. The interfaces include those data interfaces which exist between the Plant Control System (PCS) and Data Management System (DMS), between the DMS and Non-Destructive Assay (NDA) equipment, and between the DMS and Boxed Waste Assay System (BWAS) equipment. In addition to the data interfaces between the various WRAP computer systems; there are also a number of control functions between WRAP 1 equipment. These control function interfaces have been specified in WRAP Construction specification 13462 and the associated equipment specifications. The PCS vendor has been listed in the equipment specifications as the responsible party for establishing the final control system interface between the PCS and Non-Destructive Examination (NDE) Equipment, the PCS and Non-Destructive Assay (NDA) Equipment, and the PCS and BWAS equipment. The primary interface requirements between these systems are addressed in Specification Sections 13462, 13532, 13533, 13026, 13537, and 13538. Additional requirements may be found in other specification sections such as the Automatic Stacker Retriever System (AS/RS) Technical Specification 14520 and the WRAP 1 Data Management System Software Requirements Specification

    14. The LLNL portable tritium processing system

      International Nuclear Information System (INIS)

      Anon.

      1995-01-01

      The end of the Cold War significantly reduced the need for facilities to handle radioactive materials for the US nuclear weapons program. The LLNL Tritium Facility was among those slated for decommissioning. The plans for the facility have since been reversed, and it remains open. Nevertheless, in the early 1990s, the cleanup (the Tritium Inventory Removal Project) was undertaken. However, removing the inventory of tritium within the facility and cleaning up any pockets of high-level residual contamination required that we design a system adequate to the task and meeting today's stringent standards of worker and environmental protection. In collaboration with Sandia National Laboratory and EG ampersand G Mound Applied Technologies, we fabricated a three-module Portable Tritium Processing System (PTPS) that meets current glovebox standards, is operated from a portable console, and is movable from laboratory to laboratory for performing the basic tritium processing operations: pumping and gas transfer, gas analysis, and gas-phase tritium scrubbing. The Tritium Inventory Removal Project is now in its final year, and the portable system continues to be the workhorse. To meet a strong demand for tritium services, the LLNL Tritium Facility will be reconfigured to provide state-of-the-art tritium and radioactive decontamination research and development. The PTPS will play a key role in this new facility

    15. İnsani Güvenlik Kavramı Bağlamında Çevre Güvenliği

      Directory of Open Access Journals (Sweden)

      Engin İ. ERDEM

      2016-12-01

      Full Text Available Güvenlik çalışmaları Soğuk Savaş’ın sona ermesinden sonraki dönemde giderek genişleyen bir günde­me sahip olmuştur. Bu makalede genişleyen güvenlik gündeminde yer alan insani güvenlik kavramı bağlamında çevresel güvenlik konusu incelenecektir. Çalışma öncelikle insani güvenlik kavramının ne zaman ortaya çıktığını ve farklı insanı güvenlik tanımlarından bahsetmektedir. 1994 yılı Birleşmiş Milletler Kalkınma Raporu insani güvenlik kavramının ortaya çıkışı açısından dönüm noktası olurken, tanımlar arasında iki tanesi ağırlık kazanmıştır. Geniş tanımlamada yoksulluk ve kalkınma temel dinamikler olarak alınırken dar insani güvenlik tanımlamasında fiziki şiddetin kullanılması baz olarak alınmıştır. Öte yandan, insani güvenlik etrafındaki tartışmaların önemli ölçüde normatif ve kuramsal boyutlara sahip olduğu görülmektedir. Bu sebeple makale başlıca uluslararası ilişkiler teorilerinin in­sani güvenlik olgusuna nasıl baktıklarına da yer vermektedir. Realist teoriler insani güvenlik kavramı ile ilgilenmezken liberal, inşacı ve eleştirel kuramların insani güvenlik olgusu ile ilgili oldukları görül­mektedir. Çalışmanın daha sonraki bölümü başta küresel ısınma olmak üzere çeşitli çevre sorunlarının insani güvenlik ve devletlerarası ilişkiler açısından nasıl tehlike oluşturduklarını analiz etmektedir. Bu bağlamda önemli bir konu çevresel güvensizlik ya da çevre felaketlerinden kaynaklanan devlet içi ve uluslararası göçlerin devletlerin istikrarını bozabilecek olması ve devletlerarası çatışmalara yol açabilme­sidir. Çevresel güvenlik sorunları Darfur ve Suriye’de olduğu gibi sıcak çatışmaların ortaya çıkmasında önemli bir etkiye sahip olabilmektedirler. Çalışmanın sonuç kısmı, insani güvenlik ve çevresel güvenlik kavramlarının güvenlik çalışmaları alan

    16. Kuş Gölü (Bandırma Makrobentik Omurgasız Faunası Hakkında Bir Ön Araştırma.

      Directory of Open Access Journals (Sweden)

      Süleyman Balık

      2015-12-01

      Full Text Available Kuş Gölü’nün makrobentik omurgasız faunasını belirlemek amacıyla 1987 ve 1988 yılları arasında aylık periyotlar halinde, bir yıl süre ile 5 istasyonda arazi çalışması yapılmıştır. Ekman grab ile alınan çamur örnekleri 500 μm göz açıklığındaki elekten geçirilmiş ve örnekler %4’lük formaldehit solüsyonunda tespit edilmiştir. Araştırma sonucunda, Oligochaeta sınıfından 10, Chironomidae familyasından 5 ve Ceratopogonidae familyasından 1 olmak üzere toplam 16 takson tespit edilmiştir. Kuş gölü’nde metrekarede ortalama 6759 birey tespit edilmiş, grupların oransal dağılımında %81,94 ile Oligochaeta bireylerinin en baskın grubu oluşturduğu, bu grubu Chironomidae (%17,90 ve Ceratopogonidae (%0,16 larvalarının takip ettiği saptanmıştır. Tespit edilen grupların istasyonlara göre oransal dağılımlarında ise, 1. istasyonun en zengin (%28,71, 4. istasyonun en fakir (%12,77 istasyon olduğu gözlenmiştir

    17. Variable-speed, portable routing skate

      Science.gov (United States)

      Pesch, W. A.

      1967-01-01

      Lightweight, portable, variable-speed routing skate is used on heavy metal subassemblies which are impractical to move to a stationary machine. The assembly, consisting of the housing with rollers, router, and driving mechanism with transmission, weighs about forty pounds. Both speed and depth of cut are adjustable.

    18. Kozak Yöresi Fıstıkçamı (Pinus pinea L. ormanlarında fıstık verimi ile artım ve bazı meteorolojik olaylar arasındaki ilişkiler

      Directory of Open Access Journals (Sweden)

      Dr. Mustafa BATUR

      2016-01-01

      Full Text Available Bu çalışmada, Kozak yöresindeki fıstıkçamı ormanlarında fıstık veriminin çap artımı ve meteorolojik olaylarla ilişkileri araştırılmıştır.İlişkilerin ortaya konması için 2006-2011 yılları arasındaki yıllık çap artım verileri, meteorolojik veriler ve örnek ağaçlara ait fıstık verimleri kullanılmıştır.Yapılan değerlendirmede; çap artımı ile fıstık verimi arasında önemli bir bulunamamıştır. Ancak, bazı meteorolojik olaylar ile fıstık verimi arasında ilişkilerin olduğu saptanmıştır. Özellikle, kabuklu fıstık verimi ile bir önceki yılın vejetasyon dönemindeki toplam yağış miktarı arasında R2=0,81, iki yıl önceki vejetasyon dönemindeki toplam yağış miktarı arasında R2=0,79 seviyesinde ilişki saptanmıştır. Fıstık veriminin kozalakların olgunlaştığı yıldaki meteorolojik olaylardan daha çok tozlaşma ve kozalakların büyüme dönemlerindeki meteorolojik verilerle ilişkili olduğu tahmin edilmektedir.

    19. Development of portable flow calibrator

      International Nuclear Information System (INIS)

      Akiyama, Kiyomitsu; Iijima, Nobuo

      1995-01-01

      In the nuclear facilities, air sniffer system is often utilized to evaluate atmospheric concentration of radioactivity in the working environment. The system collects airborne dust on the filter during some sampling period. In this method, total air flow during the sampling period is an important parameter to evaluate the radioactivity concentration correctly. Therefore, calibration for the flow meter of air sniffer system must be done periodically according to Japan Industry Standards (JIS). As we have had to available device to calibrate the flow meter in the working area, we had to remove the flow meters from the installed place and carry them to another place where calibration can be made. This work required a great deal of labor. Now we have developed a portable flow calibrator for air sniffer system which enables us to make in-site calibration of the flow meter in the working area more easily. This report describes the outline of portable flow calibrator and it's experimental results. (author)

    20. Safeguards instrumentation for continuous unattended monitoring in plutonium fuel fabrication plants

      International Nuclear Information System (INIS)

      Menlove, H.O.; Miller, M.C.; Ohtani, T.; Seya, M.; Takahashi, S.

      1993-01-01

      Nondestructive assay (NDA) systems have been developed for use in an automated mixed oxide fabrication facility. Unique features have been developed for the NDA systems to accommodate robotic sample handling and remote operation. In addition, the systems have been designed to obtain International Atomic Energy Agency inspection data without the need for an inspector at the facility at the time of the measurements. The equipment is being designed to operate continuously in an unattended mode with data storage for periods of up to one month. The design, performance characteristics, and authentication of the NDA systems are described. The data related to reliability, precision, and accuracy are presented

    1. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) ; Guidance on the scientific requirements for health claims related to bone, joints, skin and oral health

      DEFF Research Database (Denmark)

      Tetens, Inge

      The Panel on Dietetic Products, Nutrition and Allergies (NDA) has been asked by the European Food Safety Authority (EFSA) to draft guidance on the scientific requirements for health claims related to bone, joints, skin, and oral health. This guidance has been drawn from scientific opinions...

    2. Metal detecting, collecting and portable antiquities: Scottish and British perspectives

      Directory of Open Access Journals (Sweden)

      Stuart Campbell

      2013-03-01

      Full Text Available While it is common to focus on the detail and intent of heritage law, this article focuses instead on the social and cultural attitudes of both archaeologists and finders towards the finding and ownership of portable antiquities, not least in the different laws regarding portable antiquities that operate within the United Kingdom.

    3. Portable power applications of fuel cells

      Energy Technology Data Exchange (ETDEWEB)

      Weston, M.; Matcham, J.

      2002-07-01

      This report describes the state-of-the-art of fuel cell technology for portable power applications. The study involved a comprehensive literature review. Proton exchange membrane fuel cells (PEMFCs) have attracted much more interest than either direct methanol fuel cells (DMFCs) or solid oxide fuel cells (SOFCs). However, issues relating to fuel choice and catalyst design remain with PEMFCs; DMFCs have excellent potential provided issues relating to the conducting membrane can be resolved but the current high temperature of operation and low power density currently makes SOFCs less applicable to portable applications. Available products are listed and the obstacles to market penetration are discussed. The main barriers are cost and the size/weight of fuel cells compared with batteries. Another key problem is the lack of a suitable fuel infrastructure.

    4. ONE-STEP AND TWO-STEP CALIBRATION OF A PORTABLE PANORAMIC IMAGE MAPPING SYSTEM

      Directory of Open Access Journals (Sweden)

      P.-C. Wang

      2012-07-01

      Full Text Available A Portable Panoramic Image Mapping System (PPIMS is proposed for rapid acquisition of three-dimensional spatial information. By considering the convenience of use, cost, weight of equipment, precision, and power supply, the designed PPIMS is equipped with 6 circularly arranged cameras to capture panoramic images and a GPS receiver for positioning. The motivation for this design is to develop a hand-held Mobile Mapping System (MMS for some difficult accessing areas by vehicle MMS, such as rugged terrains, forest areas, heavily damaged disaster areas, and crowed places etc. This PPIMS is in fact a GPS assisted close-range photogrammetric system. Compared with the traditional close-range photogrammetry, PPIMS can reduce the need of ground control points significantly. Under the condition of knowing the relative geometric relationships of the equipped sensors, the elements of exterior orientation of each captured image can be solved. However, the procedure of a system calibration should be done accurately to determine the relative geometric relationships of multi-cameras and the GPS antenna center, before the PPIMS can be applied for geo-referenced mapping. In this paper, both of one-step and two-step calibration procedures for PPIMS are performed to determine the lever-arm offsets and boresight angles among cameras and GPS. The performance of the one-step and two-step calibration is evaluated through the analysis of the experimental results. The comparison between these two calibration procedures was also conducted. The two-step calibration method outperforms the one-step calibration method in terms of calibration accuracy and operation convenience. We expect that the proposed two-step calibration procedure can also be applied to other platform-based MMSs.

    5. A Study on Immersion and Presence of a Portable Hand Haptic System for Immersive Virtual Reality.

      Science.gov (United States)

      Kim, Mingyu; Jeon, Changyu; Kim, Jinmo

      2017-05-17

      This paper proposes a portable hand haptic system using Leap Motion as a haptic interface that can be used in various virtual reality (VR) applications. The proposed hand haptic system was designed as an Arduino-based sensor architecture to enable a variety of tactile senses at low cost, and is also equipped with a portable wristband. As a haptic system designed for tactile feedback, the proposed system first identifies the left and right hands and then sends tactile senses (vibration and heat) to each fingertip (thumb and index finger). It is incorporated into a wearable band-type system, making its use easy and convenient. Next, hand motion is accurately captured using the sensor of the hand tracking system and is used for virtual object control, thus achieving interaction that enhances immersion. A VR application was designed with the purpose of testing the immersion and presence aspects of the proposed system. Lastly, technical and statistical tests were carried out to assess whether the proposed haptic system can provide a new immersive presence to users. According to the results of the presence questionnaire and the simulator sickness questionnaire, we confirmed that the proposed hand haptic system, in comparison to the existing interaction that uses only the hand tracking system, provided greater presence and a more immersive environment in the virtual reality.

    6. A Study on Immersion and Presence of a Portable Hand Haptic System for Immersive Virtual Reality

      Science.gov (United States)

      Kim, Mingyu; Jeon, Changyu; Kim, Jinmo

      2017-01-01

      This paper proposes a portable hand haptic system using Leap Motion as a haptic interface that can be used in various virtual reality (VR) applications. The proposed hand haptic system was designed as an Arduino-based sensor architecture to enable a variety of tactile senses at low cost, and is also equipped with a portable wristband. As a haptic system designed for tactile feedback, the proposed system first identifies the left and right hands and then sends tactile senses (vibration and heat) to each fingertip (thumb and index finger). It is incorporated into a wearable band-type system, making its use easy and convenient. Next, hand motion is accurately captured using the sensor of the hand tracking system and is used for virtual object control, thus achieving interaction that enhances immersion. A VR application was designed with the purpose of testing the immersion and presence aspects of the proposed system. Lastly, technical and statistical tests were carried out to assess whether the proposed haptic system can provide a new immersive presence to users. According to the results of the presence questionnaire and the simulator sickness questionnaire, we confirmed that the proposed hand haptic system, in comparison to the existing interaction that uses only the hand tracking system, provided greater presence and a more immersive environment in the virtual reality. PMID:28513545

    7. Power Conditioning of Fuel Cell Systems in Portable Applications

      Energy Technology Data Exchange (ETDEWEB)

      Moreno-Benitez, E.; Brey, J. J.; Rodriguez-Bordallo, C.; Carrasco, J. M.; Galvan, E.

      2005-07-01

      The achieving of high performance and long useful life are the two fundamental objectives of portable application designers. Cost and size conditions make these objectives more complex and always lead to a compromise solution having to be reached. The most significant parameters as regards portables devices are cost, efficiency (useful life), output crimps and noise, and quiescent current. Most portable products have two fundamental operating modes: active and standby. During the active period, current consumption is generally high and this means that excellent conversion is essential in order to maximize the useful life of the device that supplies current and voltage. However, most portable devices spend most of their time on standby and draw little energy from the source. It is equally important for the source to be very efficient under these conditions. This means that the quiescent current from the source (the current that supplies in low or nil load conditions) must be much lower than the load current in order to maintain high efficiency. Topologies Different power conditioning topologies to be used in portable applications are indicated with their corresponding advantages and inconveniences being specified. Low dropout voltage regulator (LDO) This type of conditioning is one of minimum cost, noise and quiescent current. This makes this device a favorite for many applications. Its external components are minimal: usually a bypass capacity. Its efficiency, although poor when Vin is much greater than Vout, increases greatly when their values are somewhat similar. In this event, the benefits of using LDOs are almost impossible to beat. In fact, these circuits are much used to reach output voltages of up to 3 volts. (Author)

    8. Minimum radwaste system to support commercial operation-what equipment can be deferred

      International Nuclear Information System (INIS)

      Marshall, R.W.; Tafazzoli, M.M.

      1984-01-01

      Because of cash flow problems being experienced by utilities as nuclear power stations approach completion, areas of the plant for which the completion of the construction effort could be deferred past commercial operation should be reviewed. The radwaste treatment systems are prime candidates for such a deferral because of the availability, either temporary or permanent, of alternative treatment methods for the waste streams expected to be produced. In order to identify the radwaste equipment, components and associated hardware in the radwaste building which could be deferred past commercial operation, a study was performed by Impell Corporation to evaluate the existing radwaste treatment system and determine the minimum system necessary to support commercial operation of a typical BWR. The study identified the minimum-installed radwaste treatment system which, in combination with portable temporary equipment, would accommodate the waste types and quantities likely to be produced in the first few years of operation. In addition, the minimum-installed system had to be licensable and excessive radiation exposures should not be incurred during the construction of the deferred portions of the system after commercial operation. From this study, it was concluded that a significant quantity of radwaste processing equipment and the associated piping, valves and instrumentation could be deferred. The estimated savings, in construction manhours (excluding field distributables) alone, was over 102,000 M-H

    9. Stereotipik Davranışların Azaltılmasında Kullanılan Yöntemlerin Etkililiği: Betimsel ve Meta Analizi

      Directory of Open Access Journals (Sweden)

      Özlem Toper Korkmaz

      2010-07-01

      Full Text Available Yineleyici, tekrarlanan davranış olarak tanımlanan stereotipi, farklı gelişimsel yetersizlik türlerinde görülmekle beraber, yaygın olarak otistik bozukluk (otizm gösteren bireylerde de gözlenmekte ve otistik bozukluğun ayırıcı tanı ölçütlerinden birini oluşturmaktadır. Geçmişten günümüze çeşitli yöntemlerin stereotipik davranışların azaltılmasında kullanıldığı görülmektedir. Bu çalışmada da stereotipik davranışların azaltılmasında kullanılan yöntemlerin etkililiklerini incelemek amaçlanmıştır. Bu amaçla 1996 ile 2010 yılları arasında tarama yapılarak otistik bozukluk gösteren bireylerde vokal ya da motor stereotipi veya her ikisinin birden azaltılmasının amaçlandığı toplam 18 araştırma betimsel ve meta analizi yapılarak incelenmiştir. Araştırmanın betimsel analiz sonuçları stereotipik davranışların azaltılmasında kullanılan yöntemlerin etkili olduğunu gösterirken, meta analizi sonuçları yöntemlerin “şüpheli” olduğu sonucunu göstermiştir. Stereotypic behavior is defined repetitive behaviors observed various types of developmental disorders, especially in autism and is also a discriminative criterion to diagnose the autism. Various procedures have been used to reduce the stereotypic behaviors in individuals with these behaviors. The purpose of this study is to investigate the procedures’ effectiveness about reducing the stereotypic behaviors. A total of 18 studies were examined published in between 1996 and 2010 about reducing vocal stereotypy, motor stereotypy or both of them. Descriptive and meta-analysis were carried out on these studies. Whereas results of descriptive analysis revealed that the examined procedures are effective to reduce the stereotypic behaviors, results of meta-analysis showed that these procedures are “uncertain”.

    10. Study of multi-functional precision optical measuring system for large scale equipment

      Science.gov (United States)

      Jiang, Wei; Lao, Dabao; Zhou, Weihu; Zhang, Wenying; Jiang, Xingjian; Wang, Yongxi

      2017-10-01

      The effective application of high performance measurement technology can greatly improve the large-scale equipment manufacturing ability. Therefore, the geometric parameters measurement, such as size, attitude and position, requires the measurement system with high precision, multi-function, portability and other characteristics. However, the existing measuring instruments, such as laser tracker, total station, photogrammetry system, mostly has single function, station moving and other shortcomings. Laser tracker needs to work with cooperative target, but it can hardly meet the requirement of measurement in extreme environment. Total station is mainly used for outdoor surveying and mapping, it is hard to achieve the demand of accuracy in industrial measurement. Photogrammetry system can achieve a wide range of multi-point measurement, but the measuring range is limited and need to repeatedly move station. The paper presents a non-contact opto-electronic measuring instrument, not only it can work by scanning the measurement path but also measuring the cooperative target by tracking measurement. The system is based on some key technologies, such as absolute distance measurement, two-dimensional angle measurement, automatically target recognition and accurate aiming, precision control, assembly of complex mechanical system and multi-functional 3D visualization software. Among them, the absolute distance measurement module ensures measurement with high accuracy, and the twodimensional angle measuring module provides precision angle measurement. The system is suitable for the case of noncontact measurement of large-scale equipment, it can ensure the quality and performance of large-scale equipment throughout the process of manufacturing and improve the manufacturing ability of large-scale and high-end equipment.

    11. Development of a portable report writer for radiology

      International Nuclear Information System (INIS)

      Dockray, K.T.; Forgey, M.K.

      1985-01-01

      This paper describes an x-ray report writer crafted for a radiologist serving eight widely spread rural hospitals and clinics. Transcribed reports, originally taking one to seven days to turn out, are now code-generated on a portable computer. If one is to save effort and money in x-ray with computer techniques, then those techniques must respond within the constraints of how radiologists do radiology. This paper reviews classic x-ray work methods, describes the generation of typed film reports with a portable, standalone computer, and then analyzes its effects

    12. A portable high-efficiency electromagnetic energy harvesting system using supercapacitors for renewable energy applications in railroads

      International Nuclear Information System (INIS)

      Zhang, Xingtian; Zhang, Zutao; Pan, Hongye; Salman, Waleed; Yuan, Yanping; Liu, Yujie

      2016-01-01

      Graphical abstract: In this study, we develop a portable high-efficiency electromagnetic energy harvesting system with supercapacitors that converts the energy of track vibrations into electricity. The generated electricity is stored in the supercapacitors and used in remote areas for safety facilities or in standby power supplies for rail-side equipment. The proposed system consists of a mechanical transmission and a rectifier. Acting as the energy input and transmission, Gears and a rack amplify the small vibrations of the track, and one-way bearings enhance efficiency by transforming bidirectional motion to unidirectional rotation. Supercapacitors are used in the energy harvesting system for the first time. The supercapacitors permit the storage of energy from rapidly changing transient currents and a steady power supply for external loads. The proposed system is demonstrated through dynamic simulations, which show the rapid response of the system. An efficiency of 55.5% is demonstrated in bench tests, verifying that the proposed electromagnetic energy harvesting system is effective and practical in renewable energy applications for railroads. - Highlights: • A frequently ignored source of energy, railroad track vibrations, is harvested. • A novel conversion mechanism is designed to maximize efficiency. • Supercapacitors are included in the electromagnetic energy harvesting system. • A portable design is proposed for wider application. - Abstract: As the demand for alternative sources of energy has increased, harvesting abundant environmental energy such as vibration energy including track vibrations in railway systems has attracted greater attention. In this study, we develop a portable high-efficiency electromagnetic energy harvesting system with supercapacitors that converts the energy of track vibrations into electricity. The generated electricity is stored in the supercapacitors and used in remote areas for safety facilities or in standby power

    13. Cardiovascular fitness strengthening using portable device.

      Science.gov (United States)

      Alqudah, Hamzah; Kai Cao; Tao Zhang; Haddad, Azzam; Su, Steven; Celler, Branko; Nguyen, Hung T

      2016-08-01

      The paper describes a reliable and valid Portable Exercise Monitoring system developed using TI eZ430-Chronos watch, which can control the exercise intensity through audio stimulation in order to increase the Cardiovascular fitness strengthening.

    14. Farklı stres koşullarında Rhodotorula glutinis’ten antioksidan üretimi için biyoproses koşullarının geliştirilmesi

      OpenAIRE

      ÜNLÜ BÜYÜKTOPÇU, Ayşe Ezgi

      2012-01-01

         Çalışmada, antioksidan enzimler sınıfında yer alan süperoksit dismutaz (SOD) ve katalaz (KAT) enzimlerinin, Rhodotorula glutinis mayasından yüksek aktivite ile üretimi için biyoproses koşulları araştırılmıştır. Küçük ölçek (100 ml) ve kesikli işletimde sıcaklık, başlangıç ph değeri, karbon ve azot kaynaklarının etkisi incelendikten sonra, deney tasarımı yapılmıştır. SOD aktivitesinin optimum koşullarında küçük ...

    15. EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA); Scientific Opinion on Dietary Reference Values for carbohydrates and dietary fibre

      OpenAIRE

      Tetens, Inge

      2011-01-01

      This Opinion of the EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA) deals with the establishment of Dietary Reference Values for carbohydrates and dietary fibre. Nutritionally, two broad categories of carbohydrates can be differentiated: “glycaemic carbohydrates”, i.e. carbohydrates digested and absorbed in the human small intestine, and „dietary fibre‟, non-digestible carbohydrates passing to the large intestine. In this Opinion, dietary fibre is defined as non-digestible car...

    16. Ortaöğretim Tarih Ders Kitaplarında Yer Alan Barış ve Antlaşmalar Üzerine Bir Değerlendirme

      Directory of Open Access Journals (Sweden)

      Özgür Aktaş

      2013-05-01

      Full Text Available Bu çalışmanın amacı ortaöğretim tarih ders kitaplarında yer alan antlaşma ve barış konularının içeriğinin nasıl düzenlendiğini değerlendirmektir. Araştırmanın yöntemi doküman analizine dayanmaktadır. Bu çalışmada ders kitaplarında anlatılan antlaşmaların anlatılış tarzları tespit edilmiştir. Antlaşmalar iki gruba ayrılarak değerlendirilmiştir. Birincisi doğrudan anlatılan antlaşmalar, ikincisiyse bir parça ya da metin içerisinde anlatılan antlaşmalardır. Ortaöğretim tarih ders kitaplarına bakıldığında antlaşmalar ve barışlar önemli oranda yer tutmaktadır. Tarih ders kitaplarında savaşlar ve antlaşmalar anlatılırken zengin görsellerin kullanıldığı görülmektedir. Bununla beraber antlaşmalar anlatılırken akıl yürütme, tartışma, eleştirel düşünme gibi tekniklerin kullanılmasında eksiklikler olduğu görülmektedir. Türkiye Cumhuriyeti İnkılâp Tarihi ve Atatürkçülük tarih ders kitabında antlaşmalar çoğunlukla doğrudan anlatılmıştır. Çağdaş Türk ve Dünya Tarihi dersinin programına alınması öğrencilerinde bilmeleri gereken savaşları ve antlaşmaları da fazlasıyla arttırmıştır. Bu antlaşmaların daha iyi anlatılmasının en iyi yolunun konunun öğretimini kolaylaştıracak etkinlik kitaplarının geliştirilmesi olduğu düşünülmektedir. Anahtar Kelimeler: Savaş, Antlaşma, Barış, Tarih, Tarih Eğitimi  A Study into Peaces and Treaties in the History Course Books of Secondary EducationAbstract: The purpose of the current study was to investigate how the content of the treaties and peace subjects in the history course books of secondary education was arranged. The method of the research based on document analysis. In this study, the styles of giving the treaties told in the course books were determined. The treaties were classified in two groups and analysed. First one was the treaties directly told and the second one was

    17. Dağıtım Kanallarında Çatışma Nasıl Önlenebilir?/Prevention of Conflict in Distribution Channels

      OpenAIRE

      Güreş, Nuriye

      2014-01-01

      Müşteri memnuniyetinin önem kazandığı günümüzde, müşterinin talep ettiği ürün ve hizmetleri doğru yerde, doğru zamanda ve doğru fiyattan sunmak işletmeler açısından büyük önem arz etmektedir. Bu noktada, ürün ve hizmetlerin müşterilere ulaştırılmasında etkin rol oynayan dağıtım kanallarının önemi ortaya çıkmaktadır. Dolayısıyla bu çalışmada, müşterilere istedikleri ürün ve hizmetleri ulaştırmada çok önemli yeri olan dağıtım kanalları üzerinde durularak, dağıtım kanallarında çeşitli sebeplerl...

    18. Portable File Format (PFF) specifications

      Energy Technology Data Exchange (ETDEWEB)

      Dolan, Daniel H. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

      2015-02-01

      Created at Sandia National Laboratories, the Portable File Format (PFF) allows binary data transfer across computer platforms. Although this capability is supported by many other formats, PFF files are still in use at Sandia, particularly in pulsed power research. This report provides detailed PFF specifications for accessing data without relying on legacy code.

    19. A portable luminescence dating instrument

      DEFF Research Database (Denmark)

      Kook, M.H.; Murray, A.S.; Lapp, Torben

      2011-01-01

      We describe a portable luminescence reader suitable for use in remote localities in the field. The instrument weighs about 8kg and is based around a 30mm bialkali photomultiplier detecting signals through a glass filter centered on 340nm. Stimulation is by 470nm blue LEDs (24W in total) operating...

    20. In-use NOx emissions from model year 2010 and 2011 heavy-duty diesel engines equipped with aftertreatment devices.

      Science.gov (United States)

      Misra, Chandan; Collins, John F; Herner, Jorn D; Sax, Todd; Krishnamurthy, Mohan; Sobieralski, Wayne; Burntizki, Mark; Chernich, Don

      2013-07-16

      The California Air Resources Board (ARB) undertook this study to characterize the in-use emissions of model year (MY) 2010 or newer diesel engines. Emissions from four trucks: one equipped with an exhaust gas recirculation (EGR) and three equipped with EGR and a selective catalytic reduction (SCR) device were measured on two different routes with three different payloads using a portable emissions measurement system (PEMS) in the Sacramento area. Results indicated that brake-specific NOx emissions for the truck equipped only with an EGR were independent of the driving conditions. Results also showed that for typical highway driving conditions, the SCR technology is proving to be effective in controlling NOx emissions. However, under operations where the SCR's do not reach minimum operating temperature, like cold starts and some low load/slow speed driving conditions, NOx emissions are still elevated. The study indicated that strategies used to maintain exhaust temperature above a certain threshold, which are used in some of the newer SCRs, have the potential to control NOx emissions during certain low-load/slow speed driving conditions.

    1. Use of rechargeable nickel-cadmium batteries for portable radiation monitors

      International Nuclear Information System (INIS)

      Zaman, M.Q.

      1987-08-01

      An effort was taken to assess the chargers available at the local market and the use of rechargeable batteries in the portable radiation monitors. This report is a very brief description of the study and observations. In order to have fair and justified conclusions regarding the use of Ni-Cd battery in portable instruments, many criterions have to be considered which takes very long observations under some specified conditions. This report is a combination of previous experimental results by scientists, data supplied by the manufacturers and short time observations in Seibersdorf Laboratory. The report has three parts (a) comparison of the ordinary battery with the rechargeables (b) selection of a suitable charger and (c) probability of application of the Ni-Cd battery in portable dosimeters

    2. Design and operational experience with a portable tritium cleanup system

      International Nuclear Information System (INIS)

      Maienschein, J.L.; Wilson, S.W.; Garcia, F.

      1991-06-01

      We built a portable tritium cleanup system to scavenge tritium from contaminated gases in any tritium-containing system in the LLNL Tritium Facility. The cleanup system uses standard catalytic oxidation of tritium to water followed by water removal with a molecular sieve dryer. The cleanup unit, complete with instrumentation, is contained in a portable cart that is rolled into place and connected to the apparatus to be cleaned. The cleanup systems is effective, low-tech, simple, and reliable. The nominal flow rate of the system is 30 liters/minute, and the decontamination factor is > 1000. In this paper we will show design information on our portable cleanup system, and will discuss our operational experience with it over the past several years

    3. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on Dietary Reference Values for protein

      DEFF Research Database (Denmark)

      Tetens, Inge

      This opinion of the EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) deals with the setting of Dietary Reference Values (DRVs) for protein. The Panel concludes that a Population Reference Intake (PRI) can be derived from nitrogen balance studies. Several health outcomes possibly...... for growth and maintenance. For pregnancy, an intake of 1, 9 and 28 g/d in the first, second and third trimesters, respectively, is proposed in addition to the PRI for non-pregnant women. For lactation, a protein intake of 19 g/d during the first six months, and of 13 g/d after six months, is proposed...

    4. Eğirdir orman fidanlığı’nda diken ardıcı (Juniperus oxycedrus fidan yetiştirme sıklığının fidan morfolojisine etkileri

      Directory of Open Access Journals (Sweden)

      Esra ALIM

      2017-07-01

      Full Text Available Bu çalışmada, farklı yetiştirme sıklıklarının diken ardıcı (Juniperus oxycedrus L. subsp. oxycedrus’nın (1+0 çıplak köklü fidanlarının morfolojik özellikleri üzerindeki etkilerini ortaya koymak amaçlanmıştır. Araştırma Eğirdir Orman Fidanlığında kurulan deneme alanlarında yürütülmüştür. Denemede; 1.5 cm, 3 cm, 6 cm ve 9 cm mesafe olacak şekilde kontrol dâhil 5 farklı yetiştirme sıklığı uygulanmıştır. Araştırma sonuçlarına göre diken ardıcı fidanlarının morfolojik özellikleri (kök boğazı çapı, yan kök sayısı, gürbüzlük indisi, kalite indisi, fidan, gövde ve kök taze ağırlıkları ile fidan, gövde ve kök kuru ağırlıkları üzerine yetiştirme sıklığının önemli etkilerinin olduğu belirlenmiştir. Ekim yastıklarında yetiştirme sıklığı azaldıkça daha kalın çaplı, gövde taze ve kuru ağırlığı daha fazla ve daha çok yan kök sayısına sahip olan fidanlar elde edilmiştir. Çalışmada, elde edilen fidanlar arasında en yüksek kök boğazı çapı ve yan kök sayısı kontrol dışındaki ekim sıklıklarından elde edilen fidanlarda olduğu tespit edilmiştir. Fidan ağırlıkları bakımından ise en iyi sonucu 3 cm ekim sıklığı verirken, en düşük sonuç kontrol fidanlarında meydana gelmiştir. Eğirdir Orman Fidanlığı koşullarında 3 cm ekim sıklığının uygulanmasının kaliteli diken ardıcı fidan üretimi için yeterli olacağı düşünülmektedir.

    5. 47 CFR 80.53 - Application for a portable ship station license.

      Science.gov (United States)

      2010-10-01

      ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Application for a portable ship station license... SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Applications and Licenses § 80.53 Application for a portable ship station license. The Commission may grant a license permitting operation of a...

    6. Portable Wind Energy Harvesters for Low-Power Applications: A Survey.

      Science.gov (United States)

      Nabavi, Seyedfakhreddin; Zhang, Lihong

      2016-07-16

      Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechanisms for trapping wind flow from ambient environment. In this regard, rotational and aeroelastic mechanisms are analyzed for the portable wind energy harvesting devices. The comparison between both mechanisms shows that the aeroelastic mechanism has promising potential in producing an energy harvester in smaller scale although how to maintain the resonator perpendicular to wind flow for collecting the maximum vibration is still a major challenge to overcome for this mechanism. Furthermore, this paper categorizes the previously published portable wind energy harvesters to macro and micro scales in terms of their physical dimensions. The power management systems are also surveyed to explore the possibility of improving energy conversion efficiency. Finally some insights and research trends are pointed out based on an overall analysis of the previously published works along the historical timeline.

    7. 46 CFR 169.567 - Portable extinguishers.

      Science.gov (United States)

      2010-10-01

      ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS... permit the use of any approved fire extinguishers, including semiportable extinguishers, which provide equivalent fire protection. (c) All portable fire extinguishers installed on vessels must be of an approved...

    8. A portable storage maximum thermometer

      International Nuclear Information System (INIS)

      Fayart, Gerard.

      1976-01-01

      A clinical thermometer storing the voltage corresponding to the maximum temperature in an analog memory is described. End of the measurement is shown by a lamp switch out. The measurement time is shortened by means of a low thermal inertia platinum probe. This portable thermometer is fitted with cell test and calibration system [fr

    9. Temporary/portable nuclear fallout shelter

      Energy Technology Data Exchange (ETDEWEB)

      Hampel, V E

      1991-01-15

      The design and invention of a temporary/portable fallout shelter has been described in context of schematic and representative embodiments. Tent structures are described which include disposable, exterior, semi-transparent plastic and/or fabric shield membranes covering a tent composed of stretched, tightly woven, rip-resistant fabric panels supported by tensile rods/wands. 16 figs.

    10. A set of portable radioisotopic control and measuring instruments

      International Nuclear Information System (INIS)

      Pospeev, V.V.; Sidorov, V.N.; Tesnavs, Eh.R.; Uleksin, V.I.

      1979-01-01

      The problems and perspectives are examined of the portable radioisotope instruments application in agriculture, building industry, engeeniring and geological survay and in melioration. Principles are given of creation a series of radioisotopic instruments based on the principle of ganging. The series described consists of radioisotopic densimeters and moisture gages of the portable type, based on the ganging principle. The instruments differ in the measuring converters and have unified information processing and power supply devices. Criteria are stated for the ganging principle estimation, in particular, estimation of the technical means' compatibility. Four different types of compatibility are distinguished: an information compatibility; a metrological compatibility; structural and operational compatibility. Description is given of the unified information processing device - the unified pulse counter of the SIP-1M type and description of a row of radioisotopic measuring converters, which provides a possibility for completing the portable radioisotope densimeter of the RPP-2 type, intended for measuring densities of concrets and soils in the surface layer up to 30 cm and the density range from 1000 to 2500 kg/m 3 ; portable radioisotope densimeter of the RPP-1 type having measuring range from 600 to 1500 kg/m 3 ; surface-depth radioisotopic densimeter of the PPGR-1 type and surface-depth radioisotopic moisture gage of the VPGR-1 type [ru

    11. Portable audio electronics for impedance-based measurements in microfluidics

      International Nuclear Information System (INIS)

      Wood, Paul; Sinton, David

      2010-01-01

      We demonstrate the use of audio electronics-based signals to perform on-chip electrochemical measurements. Cell phones and portable music players are examples of consumer electronics that are easily operated and are ubiquitous worldwide. Audio output (play) and input (record) signals are voltage based and contain frequency and amplitude information. A cell phone, laptop soundcard and two compact audio players are compared with respect to frequency response; the laptop soundcard provides the most uniform frequency response, while the cell phone performance is found to be insufficient. The audio signals in the common portable music players and laptop soundcard operate in the range of 20 Hz to 20 kHz and are found to be applicable, as voltage input and output signals, to impedance-based electrochemical measurements in microfluidic systems. Validated impedance-based measurements of concentration (0.1–50 mM), flow rate (2–120 µL min −1 ) and particle detection (32 µm diameter) are demonstrated. The prevailing, lossless, wave audio file format is found to be suitable for data transmission to and from external sources, such as a centralized lab, and the cost of all hardware (in addition to audio devices) is ∼10 USD. The utility demonstrated here, in combination with the ubiquitous nature of portable audio electronics, presents new opportunities for impedance-based measurements in portable microfluidic systems. (technical note)

    12. Gamma ray NDA assay system for total plutonium and isotopics in plutonium product solutions

      International Nuclear Information System (INIS)

      Cowder, L.R.; Hsue, S.T.; Johnson, S.S.; Parker, J.L.; Russo, P.A.; Sprinkle, J.K.; Asakura, Y.; Fukuda, T.; Kondo, I.

      1979-01-01

      A LASL-designed gamma-ray NDA instrument for assay of total plutonium and isotopics of product solutions at Tokai-Mura is currently installed and operating. The instrument is, optimally, a densitometer that uses radioisotopic sources for total plutonium measurements at the K absorption edge. The measured transmissions of additional gamma-ray lines from the same radioisotopic sources are used to correct for self-attenuation of passive gamma rays from plutonium. The corrected passive data give the plutonium isotopic content of freshly separated to moderately aged solutions. This off-line instrument is fully automated under computer control, with the exception of sample positioning, and operates routinely in a mode designed for measurement control. A one-half percent precision in total plutonium concentration is achieved with a 15-minute measurement

    13. Portable water quality monitoring system

      Science.gov (United States)

      Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

      2017-09-01

      Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

    14. A portable accelerator control toolkit

      Energy Technology Data Exchange (ETDEWEB)

      Watson, W.A. III

      1997-06-01

      In recent years, the expense of creating good control software has led to a number of collaborative efforts among laboratories to share this cost. The EPICS collaboration is a particularly successful example of this trend. More recently another collaborative effort has addressed the need for sophisticated high level software, including model driven accelerator controls. This work builds upon the CDEV (Common DEVice) software framework, which provides a generic abstraction of a control system, and maps that abstraction onto a number of site-specific control systems including EPICS, the SLAC control system, CERN/PS and others. In principle, it is now possible to create portable accelerator control applications which have no knowledge of the underlying and site-specific control system. Applications based on CDEV now provide a growing suite of tools for accelerator operations, including general purpose displays, an on-line accelerator model, beamline steering, machine status displays incorporating both hardware and model information (such as beam positions overlaid with beta functions) and more. A survey of CDEV compatible portable applications will be presented, as well as plans for future development.

    15. A portable accelerator control toolkit

      International Nuclear Information System (INIS)

      Watson, W.A. III.

      1997-01-01

      In recent years, the expense of creating good control software has led to a number of collaborative efforts among laboratories to share this cost. The EPICS collaboration is a particularly successful example of this trend. More recently another collaborative effort has addressed the need for sophisticated high level software, including model driven accelerator controls. This work builds upon the CDEV (Common DEVice) software framework, which provides a generic abstraction of a control system, and maps that abstraction onto a number of site-specific control systems including EPICS, the SLAC control system, CERN/PS and others. In principle, it is now possible to create portable accelerator control applications which have no knowledge of the underlying and site-specific control system. Applications based on CDEV now provide a growing suite of tools for accelerator operations, including general purpose displays, an on-line accelerator model, beamline steering, machine status displays incorporating both hardware and model information (such as beam positions overlaid with beta functions) and more. A survey of CDEV compatible portable applications will be presented, as well as plans for future development

    16. Mobile and portable dental services catering to the basic oral health ...

      African Journals Online (AJOL)

      Mobile and portable dental services catering to the basic oral health needs of the underserved population in developing countries: a proposed model. ... Though the mobile and portable systems have some practical difficulties like financial considerations, they still seem to be the only way to reach every section of the ...

    17. Selection of equipment for equipment qualification

      International Nuclear Information System (INIS)

      Torr, K.G.

      1989-01-01

      This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

    18. Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine

      International Nuclear Information System (INIS)

      Cho, Jeong Yeon; Han, Won Jeong; Kim, Eun Kyung

      2007-01-01

      The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines

    19. Beta aerosols beacon, a truly portable continuous air monitor

      International Nuclear Information System (INIS)

      Prince, R.P.; Garber, F.W.

      1987-01-01

      The Beta Aerosols Beacon (BAB) is a portable (57 lbs) continuous air monitor designed to detect airborne radiation. Utilizing solid state detectors has eliminated the use of lead shielding usually necessary for achieving accurate readings in high background areas, making the monitor lightweight as well as portable. The size of a small suitcase, it can be carried into confined work areas, eliminating the requirement for workers to wear respirators for many maintenance tasks. This paper describes the operation and applications of the BAB

    20. 47 CFR 80.271 - Technical requirements for portable survival craft radiotelephone transceivers.

      Science.gov (United States)

      2010-10-01

      ... craft radiotelephone transceivers. 80.271 Section 80.271 Telecommunication FEDERAL COMMUNICATIONS... Authorization for Compulsory Ships § 80.271 Technical requirements for portable survival craft radiotelephone transceivers. (a) Portable survival craft radiotelephone transceivers must comply with the following: (1) The...

    1. Oxygen therapy devices and portable ventilators for improved physical activity in daily life in patients with chronic respiratory disease.

      Science.gov (United States)

      Furlanetto, Karina Couto; Pitta, Fabio

      2017-02-01

      Patients with hypoxemia and chronic respiratory failure may need to use oxygen therapy to correct hypoxemia and to use ventilatory support to augment alveolar ventilation, reverse abnormalities in blood gases (in particular hypercapnia) and reduce the work of breathing. Areas covered: This narrative review provides an overview on the use of oxygen therapy devices or portable ventilators for improved physical activity in daily life (PADL) as well as discusses the issue of lower mobility in daily life among stable patients with chronic respiratory disease who present indication for long-term oxygen therapy (LTOT) or home-based noninvasive ventilation (NIV). A literature review of these concepts was performed by using all related search terms. Expert commentary: Technological advances led to the development of light and small oxygen therapy devices and portable ventilators which aim to facilitate patients' mobility and ambulation. However, the day-by-day dependence of a device may reduce mobility and partially impair patients' PADL. Nocturnal NIV implementation in hypercapnic patients seems promising to improve PADL. The magnitude of their equipment-related physical inactivity is underexplored up to this moment and more long-term randomized clinical trials and meta-analysis examining the effects of ambulatory oxygen and NIV on PADL are required.

    2. Producing nitric oxide by pulsed electrical discharge in air for portable inhalation therapy.

      Science.gov (United States)

      Yu, Binglan; Muenster, Stefan; Blaesi, Aron H; Bloch, Donald B; Zapol, Warren M

      2015-07-01

      Inhalation of nitric oxide (NO) produces selective pulmonary vasodilation and is an effective therapy for treating pulmonary hypertension in adults and children. In the United States, the average cost of 5 days of inhaled NO for persistent pulmonary hypertension of the newborn is about $14,000. NO therapy involves gas cylinders and distribution, a complex delivery device, gas monitoring and calibration equipment, and a trained respiratory therapy staff. The objective of this study was to develop a lightweight, portable device to serve as a simple and economical method of producing pure NO from air for bedside or portable use. Two NO generators were designed and tested: an offline NO generator and an inline NO generator placed directly within the inspiratory line. Both generators use pulsed electrical discharges to produce therapeutic range NO (5 to 80 parts per million) at gas flow rates of 0.5 to 5 liters/min. NO was produced from air, as well as gas mixtures containing up to 90% O2 and 10% N2. Potentially toxic gases produced in the plasma, including nitrogen dioxide (NO2) and ozone (O3), were removed using a calcium hydroxide scavenger. An iridium spark electrode produced the lowest ratio of NO2/NO. In lambs with acute pulmonary hypertension, breathing electrically generated NO produced pulmonary vasodilation and reduced pulmonary arterial pressure and pulmonary vascular resistance index. In conclusion, electrical plasma NO generation produces therapeutic levels of NO from air. After scavenging to remove NO2 and O3 and filtration to remove particles, electrically produced NO can provide safe and effective treatment of pulmonary hypertension. Copyright © 2015, American Association for the Advancement of Science.

    3. Gıdaların İyonize Radyasyonla Muhafazasında Radyasyonun Mikroorganizmalar Üzerine Etkileri

      OpenAIRE

      Özbilgin, Seher; Acar, Jale

      2015-01-01

      Gıdalarda bulunabilen mikroorganizmalar iyonlaştırıcı radyasyonla öldürülmekte veya gelişmeleri durdurulmaktadır. Bu da iyonlaştırıcı radyasyonun direkt veya indirekt etkisiyle gerçekleşmektedir. Mikroorganizmanın cinsi, vejetatif veya spor formda oluşu, ortamın bileşimi ve sıcaklık gibi faktörler ışınlara karşı duyarlılığı etkilemektedir. Mikroorganizmalar arasında bakteriler, küf ve mayalara kıyasla ışınlara daha dirençli olup, sporlu bakteriler ve özellikle C. botulinum’ un ışınlara karşı...

    4. Developing Predictive Maintenance Expertise to Improve Plant Equipment Reliability

      International Nuclear Information System (INIS)

      Wurzbach, Richard N.

      2002-01-01

      On-line equipment condition monitoring is a critical component of the world-class production and safety histories of many successful nuclear plant operators. From addressing availability and operability concerns of nuclear safety-related equipment to increasing profitability through support system reliability and reduced maintenance costs, Predictive Maintenance programs have increasingly become a vital contribution to the maintenance and operation decisions of nuclear facilities. In recent years, significant advancements have been made in the quality and portability of many of the instruments being used, and software improvements have been made as well. However, the single most influential component of the success of these programs is the impact of a trained and experienced team of personnel putting this technology to work. Changes in the nature of the power generation industry brought on by competition, mergers, and acquisitions, has taken the historically stable personnel environment of power generation and created a very dynamic situation. As a result, many facilities have seen a significant turnover in personnel in key positions, including predictive maintenance personnel. It has become the challenge for many nuclear operators to maintain the consistent contribution of quality data and information from predictive maintenance that has become important in the overall equipment decision process. These challenges can be met through the implementation of quality training to predictive maintenance personnel and regular updating and re-certification of key technology holders. The use of data management tools and services aid in the sharing of information across sites within an operating company, and with experts who can contribute value-added data management and analysis. The overall effectiveness of predictive maintenance programs can be improved through the incorporation of newly developed comprehensive technology training courses. These courses address the use of

    5. Micro-Solid Oxide Fuel Cell: A multi-fuel approach for portable applications

      International Nuclear Information System (INIS)

      Patil, Tarkeshwar C.; Duttagupta, Siddhartha P.

      2016-01-01

      Highlights: • We report the oxygen ion transport properties at the electrode–electrolyte interface (EEI) of the SOFC for the first time. • This ion transport plays a key role in the overall performance of SOFCs with different fuels. • The GIIB mechanism is also studied for the first time. • GIIB is assumed to be the prime reason for low power density and ion conductivity at the EEI when using hydrocarbon fuels. • Due to its scalability, a fuel cell can serve as a power source for on-chip applications and all portable equipment. - Abstract: The impact of oxygen ion transport at the electrolyte–electrode interface of a micro-solid oxide fuel cell using different fuels is investigated. Model validation is performed to verify the results versus the reported values. Furthermore, as the hydrogen-to-carbon ratio decreases, the diffusivity of the oxygen ion increases. This increase in diffusivity is observed because the number of hydrogen atoms available as the reacting species increases in fuels with lower hydrogen-to-carbon ratios. The oxygen ion conductivity and output power density decrease as the hydrogen-to-carbon ratio of the fuels decreases. The reason behind this impact is the formation of a gas-induced ion barrier at the electrode–electrolyte interface by the CO_2 molecules formed during the reaction at the interface, thus blocking the flow of oxygen ions. As the oxygen ions become blocked, the output current contribution from the reaction also decreases and thereby affects the overall performance of the micro-solid oxide fuel cell. The experimental verification confirms this because of a significant decrease in the output power density. Furthermore, as per the application in portable devices, the appropriate choice of fuel can be chosen so that the micro-solid oxide fuel cell operates at the maximum power density.

    6. Emulador de Master System 2 corriendo bajo PlayStation Portable

      OpenAIRE

      García Flores, Jorge

      2013-01-01

      Creación de un emulador de Master System 2 (videoconsola de SEGA) para ser ejecutado en PlayStation Portable (videoconsola de Sony), implentando los lenguajes de programación C y ensamblados. El uso de este emulador servirá para poder ejecutar los videojuegos para Master System 2 en la videoconsola PlayStation Portable. Ingeniería Técnica en Informática de Gestión

    7. Portable Wind Energy Harvesters for Low-Power Applications: A Survey

      OpenAIRE

      Seyedfakhreddin Nabavi; Lihong Zhang

      2016-01-01

      Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechan...

    8. High vacuum portable pumping station suitable for accelerator use

      International Nuclear Information System (INIS)

      Stattel, P.; Briggs, J.; DeBoer, W.; Skelton, R.

      1985-01-01

      The need for a Portable Pump Station for Ultra High Vacuum use became apparent when the ''Isabelle'' collider was first being designed. A Portable Pump Station had to be developed which contained the following features: maneuverability, compact size, rugged, self protected against various failures, capable of running unattended, and capable of reaching 10 -9 torr. The Pump Station that was developed and other variations are the subject of this paper. Emphasis will be on the Isabelle and HITL versions. 1 ref., 2 figs., 1 tab

    9. Project W-320, backup: 1000 CFM portable exhausters acceptance for beneficial use

      International Nuclear Information System (INIS)

      Nelson, O.D.

      1998-01-01

      This document is to identify the Project W-320 1000 CFM portable exhauster documentation required to be turned over from the Projects Organization to the Tank Farm Operations as part of the acceptance of the 1000 CFM portable exhausters for beneficial use

    10. A portable modular architecture for robotic manipulator control

      International Nuclear Information System (INIS)

      Butler, P.L.

      1993-01-01

      A control architecture has been developed to provide a framework for robotic manipulator control. This architecture, called the Modular Integrated Control Architecture (MICA), has been successfully applied to two different manipulator systems. MICA is a portable system in two respects. First, it can be used for the control of different types of manipulator systems. Second, the MICA code is portable across several operating environments. This portability allows the sharing of common control code among various systems. A major portion of MICA is the precise control of multiple processors that have to be coordinated to control a manipulator system. By having NUCA control the processor synchronization, the system developer can concentrate on the specific aspects of a new manipulator system. MICA also provides standard functions for trajectory generation that can be used for most manipulators. Custom trajectory generators can be easily added to suit the needs of a particular robotic control system. Another facility that MICA provides is a simulation of the manipulator, allowing the control code to be simulated before trying it on a manipulator system. Using this technique, one can develop code for a manipulator system without risking damage to the arm during development

    11. Portable Planetariums Teach Science

      Science.gov (United States)

      2015-01-01

      With the Internet proving to be the wave of the future, in the 1990s Johnson Space Center awarded grants to Rice University in Houston for developing the world's first Internet-accessible museum kiosk. Further grants were awarded to the school for creating educational software for use in homes and schools, leading to the creation of Museums Teaching Planet Earth Inc. The company has gone on to develop and sell portable planetariums and accompanying educational shows.

    12. Portable photovoltaic irrigation pumps

      Energy Technology Data Exchange (ETDEWEB)

      Furber, J. D.

      1980-07-01

      Experiences in developing a solar-powered irrigation pump to meet the needs of poor farmers in developing nations are summarized. The design which evolved is small and portable, employing a high-efficiency electric pump, powered by photovoltaic panels. Particular emphasis is placed on how the system works, and on early field problems experienced with the first prototypes. The resolution of these problems and the performance of actual systems in various countries is presented and user responses are noted.

    13. Fully portable blood irradiator

      International Nuclear Information System (INIS)

      Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

      1980-01-01

      A fully portable blood irradiator was developed using the beta emitter thulium-170 as the radiation source and vitreous carbon as the body of the irradiator, matrix for isotope encapsulation, and blood interface material. These units were placed in exteriorized arteriovenous shunts in goats, sheep, and dogs and the effects on circulating lymphocytes and on skin allograft retention times measured. The present work extends these studies by establishing baseline data for skin graft rejection times in untreated animals

    14. Portable Wind Energy Harvesters for Low-Power Applications: A Survey

      Directory of Open Access Journals (Sweden)

      Seyedfakhreddin Nabavi

      2016-07-01

      Full Text Available Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechanisms for trapping wind flow from ambient environment. In this regard, rotational and aeroelastic mechanisms are analyzed for the portable wind energy harvesting devices. The comparison between both mechanisms shows that the aeroelastic mechanism has promising potential in producing an energy harvester in smaller scale although how to maintain the resonator perpendicular to wind flow for collecting the maximum vibration is still a major challenge to overcome for this mechanism. Furthermore, this paper categorizes the previously published portable wind energy harvesters to macro and micro scales in terms of their physical dimensions. The power management systems are also surveyed to explore the possibility of improving energy conversion efficiency. Finally some insights and research trends are pointed out based on an overall analysis of the previously published works along the historical timeline.

    15. Çevre Korunmasında Atığın Atıkla Giderilmesi Prensibi / Principle Of Removal With Waste Of Waste In Environmental Protection

      Directory of Open Access Journals (Sweden)

      Utkan Özdemir

      2012-12-01

      Full Text Available Çevresel problemler göz önüne alındığında, katı atıkların bertarafı birçok dünya ülkesinin temel problemlerinden birisidir. Bu doğrultuda farklı kaynaklarda oluşan ve büyük ölçüde çeşitlilik gösteren katı atıkların bir kısmının tekrar kullanımı hedeflenmektedir. Böylece ekonomik fayda sağlanmaya çalışılmaktadır. Katı atıkların yarattığı çevre kirliliğine, su kaynaklarında meydana gelen ekolojik problemlerin de eklenmesi insanlık için daha büyük risklerin habercisidir. Dolayısıyla katı atıkların bertarafında önemli yeri olan tekrar kullanımın, sadece ekonomik faydası değil, “atığın atıkla giderim” esasına katkısı da tartışılmaya başlanmıştır. Tüketim hızının giderek arttığı dünyada, özellikle tarımsal kökenli atıkların, su arıtımında adsorbent olarak kullanılmasıyla yüksek arıtma verimleri sağlandığı gözlemlenmiştir. Bu durumu takip eden çeşitli araştırmalar, muz kabuğu, ayçiçeği sapı, pirinç kabuğu, portakal kabuğu gibi tarımsal kökenli atıkların yanı sıra kül ve arıtma çamuru gibi atıkların da organik ve inorganik bir takım kirleticilerin su ortamından arıtılmasında önemli rol oynadıklarını göstermiştir. Böylece adsorbent maliyeti nedeniyle çoğu zaman işletmeler tarafından uygun görülmeyen ve pilot ölçekli çalışma olarak kalan adsorpsiyon prosesinin kullanılabilirliğinin arttırılması şansı doğmuştur. Adsorpsiyon proseslerinin yaygınlaştırılması ile atıksu arıtımında elde edilebilecek yüksek verimlerin yanı sıra bu proseslerde adsorbent olarak kullanılan atıkların bertarafı da sağlanmış olacaktır. Aynı zamanda bu durum atıkların başka proseslerde de benzer şekilde değerlendirilmelerinin önünü açmaktadır. Bu çalışmada özellikle endüstriyel bazda kullanımlarında ekonomik ve çevresel faydalar sağlayacak atık kökenli adsorbentlerin türleri ve

    16. Marmara Bölgesi Islah Zonu’nda (200-600 m kızılçam (Pinus brutia Ten. döl denemeleri: 12. yaş sonuçları

      Directory of Open Access Journals (Sweden)

      Yrd.Doç.Dr. Murat ALAN

      2016-07-01

      Full Text Available Marmara Bölgesi Islah Zonu’nda seçilen 158 plus ağaç birinci seri ve altı adet tohum bahçesinde bulunan 160 adetklon ikinci seri olacak şekilde gruplandırılmış, toplanan açık tozlaşma ürünü tohumlardan üretilen fidanlarla iki seri kızılçam (Pinus brutia Ten. döl denemesi kurulmuştur. Deneme alanlarında 12. arazi yaşına ait boy ve göğüs çapı ölçülmüş, bu değerler kullanılarak genetik parametreler ve Best Linear Unbiased Prediction (BLUP yöntemi ile ailelerin ıslah değerleri tahmin edilmiştir. Birinci seri deneme alanlarının ortak değerlendirilmesinde boy ve çap için bireysel kalıtım derecesi sırasıyla 0,24 ve 0,16; aile ortalamaları kalıtım derecesi ise 0,52 ve 0,55; ikinci seri deneme alanlarında bireysel kalıtım derecesi aynı sırayla 0,29 ve 0,12; aile ortalamaları kalıtım derecesi ise 0,54 ve 0,45 olarak hesaplanmıştır. Boy ve göğüs çapı arasındaki genetik korelasyon birinci seri denemelerde 0,48 ve ikinci seri denemelerde ise 0,50 olarak tahmin edilmiştir. Dördüncü yaştaki boy ile 12. yaştaki boy arasında genetik korelasyon birinci seri denemelerde 0,81 ve ikinci seri denemelerde ise 0,70 bulunmuştur. B tipi genetik korelasyonlar ise birinci ve ikinci seride 0,54 - 1,00 arasında tahmin edilmiş, genotip çevre etkileşimi açısından uygulamayı etkileyecek düzeyde bulunmamıştır. Birinci seri denemelerde plus ağaç seçimleriyle genetik kazanç düşük olurken, İkinci seri denemelerde fenotipik tohum bahçelerinden boy için %4, göğüs çapı için %5 en iyi 30 klonla genetik tohum bahçesi kurulduğunda ise yine aynı sırayla %13 ve %11 genetik kazanç tahmin edilmiştir. Boy ve göğüs çapı için en yüksek ıslah değerine ulaşan 32, 35, 40 ve 188 nolu tohum bahçeleri, ağaçlandırmalarda kullanıldığında daha fazla boy ve çapa ulaşabilen bireyler elde edilebileceği anlaşılmıştır.Anahtar Kelimeler: Kalıtım derecesi, ıslah de

    17. Micro hydrogen for portable power : generating opportunities for hydrogen and fuel cells

      Energy Technology Data Exchange (ETDEWEB)

      NONE

      2006-07-01

      A new fuel cell technology for portable applications was reviewed. Success for the fuel cell industry will be achieved primarily by supplanting lithium-ion batteries, and fuel cells for portable applications have clear advantages to batteries in addition to their known environmental benefits. Micro hydrogen {sup TM} is the integrated combination of hydrogen fuel cell, hydrogen storage and delivery, fluidic interconnects and power conditioning electronics required for creating high energy density portable power sources. The small size, low heat production, environmental sustainability and refueling flexibility of the systems provides enormous economic opportunities for the use of micro hydrogen in cell phone technology, personal digital assistants and other electronic gadgets. Details of a trial to test and evaluate micro hydrogen fuel cell powered bike lights were presented. Further programs are planned for external demonstrations of high-beam search and rescue lighting, flashlights for security personnel and portable hydrogen power sources that will be used by multiple organizations throughout British Columbia. It was concluded that fuel cell technology must match the lithium-ion battery's performance by providing fast recharge, high energy density, and adaptability. Issues concerning refueling and portable and disposable cartridges for micro hydrogen systems were also discussed. 8 figs.

    18. Portability of tag SNPs across isolated population groups: an example from India.

      Science.gov (United States)

      Sarkar Roy, N; Farheen, S; Roy, N; Sengupta, S; Majumder, P P

      2008-01-01

      Isolated population groups are useful in conducting association studies of complex diseases to avoid various pitfalls, including those arising from population stratification. Since DNA resequencing is expensive, it is recommended that genotyping be carried out at tagSNP (tSNP) loci. For this, tSNPs identified in one isolated population need to be used in another. Unless tSNPs are highly portable across populations this strategy may result in loss of information in association studies. We examined the issue of tSNP portability by sampling individuals from 10 isolated ethnic groups from India. We generated DNA resequencing data pertaining to 3 genomic regions and identified tSNPs in each population. We defined an index of tSNP portability and showed that portability is low across isolated Indian ethnic groups. The extent of portability did not significantly correlate with genetic similarity among the populations studied here. We also analyzed our data with sequence data from individuals of African and European descent. Our results indicated that it may be necessary to carry out resequencing in a small number of individuals to discover SNPs and identify tSNPs in the specific isolated population in which a disease association study is to be conducted.

    19. Radiation protection instrumentation. Monitoring equipment. Radioactive aerosols in the environment

      International Nuclear Information System (INIS)

      1996-01-01

      This international standard applies to portable or installed equipment for continuous monitoring of radioactive aerosols in the environment in normal and emergency conditions. Monitoring involves continuous sampling and, where desirable, automatic start of sampling. The document applies particularly to the following assignments: (i) determination of the volume activity of radionuclides in the form of aerosols, either per time unit, along with its time changes, or in the integral form over a longer time period such as 24 h, and measurement of the volume sampled; (ii) triggering a warning alarm signal if the preset volume activity or time integral of the volume activity of aerosols has been exceeded. The document deals with radioactive aerosol monitor design, testing procedures, and documentation. Appended tables refer to the reference and normal testing conditions, tests in normal testing conditions, tests during changes of the affecting quantities, and tests of the air circuit. (P.A.)

    20. Applicability of portable spectrometer for activity measurement of contaminated water and soil samples

      International Nuclear Information System (INIS)

      Krishnan, Narayani; Rekha, A.K.; Anilkumar, S.; Sharma, D.N.

      2011-01-01

      The absolute activity measurement is often necessary to assess the impact of radioactivity contamination due to various incidents. Commercially available portable spectrometer cum dose rate meter is used for the identification of radionuclides involved and associated dose rates. In this paper the authors discusses the study carried out on the applicability of portable spectrometer for absolute radioactivity measurements in water and soil matrices. The portable spectrometer and the methodology developed for activity estimation has been used in many insitu applications. (author)