WorldWideScience

Sample records for port testing test

  1. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

  2. Final design of ITER port plug test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cerisier, Thierry, E-mail: thierry.cerisier@yahoo.fr [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Levesy, Bruno [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Romannikov, Alexander [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation); Rumyantsev, Yuri [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Cordier, Jean-Jacques; Dammann, Alexis [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Minakov, Victor; Rosales, Natalya; Mitrofanova, Elena [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Portone, Sergey; Mironova, Ekaterina [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation)

    2016-11-01

    Highlights: • We introduce the port plug test facility (purpose and status of the design). • We present the PPTF sub-systems. • We present the environmental and functional tests. • We present the occupational and nuclear safety functions. • We conclude on the achievements and next steps. - Abstract: To achieve the overall ITER machine availability target, the availability of diagnostics and heating port plugs shall be as high as 99.5%. To fulfill this requirement, it is mandatory to test the port plugs at operating temperature before installation on the machine and after refurbishment. The ITER port plug test facility (PPTF) is composed of several test stands that can be used to test the port plugs whereas at the end of manufacturing (in a non-nuclear environment), or after refurbishment in the ITER hot cell facility. The PPTF provides the possibility to perform environmental (leak tightness, vacuum and thermo-hydraulic performances) and functional tests (radio frequency acceptance tests, behavior of the plugs’ steering mechanism and calibration of diagnostics) on upper and equatorial port plugs. The final design of the port plug test facility is described. The configuration of the standalone test stands and the integration in the hot cell facility are presented.

  3. Test Port for Fiber-Optic-Coupled Laser Altimeter

    Science.gov (United States)

    Ramos Izquierdo, Luis; Scott, V. Stanley; Rinis, Haris; Cavanaugh, John

    2011-01-01

    A test port designed as part of a fiber optic coupled laser altimeter receiver optical system allows for the back-illumination of the optical system for alignment verification, as well as illumination of the detector(s) for testing the receiver electronics and signal-processing algorithms. Measuring the optical alignment of a laser altimeter instrument is difficult after the instrument is fully assembled. The addition of a test port in the receiver aft-optics allows for the back-illumination of the receiver system such that its focal setting and boresight alignment can be easily verified. For a multiple-detector receiver system, the addition of the aft-optics test port offers the added advantage of being able to simultaneously test all the detectors with different signals that simulate the expected operational conditions. On a laser altimeter instrument (see figure), the aft-optics couple the light from the receiver telescope to the receiver detector(s). Incorporating a beam splitter in the aft-optics design allows for the addition of a test port to back-illuminate the receiver telescope and/or detectors. The aft-optics layout resembles a T with the detector on one leg, the receiver telescope input port on the second leg, and the test port on the third leg. The use of a custom beam splitter with 99-percent reflection, 1-percent transmission, and a mirrored roof can send the test port light to the receiver telescope leg as well as the detector leg, without unduly sacrificing the signal from the receiver telescope to the detector. The ability to test the receiver system alignment, as well as multiple detectors with different signals without the need to disassemble the instrument or connect and reconnect components, is a great advantage to the aft-optics test port. Another benefit is that the receiver telescope aperture is fully back-illuminated by the test port so the receiver telescope focal setting vs. pressure and or temperature can be accurately measured (as

  4. Testing and Analysis of Sensor Ports

    Science.gov (United States)

    Zhang, M.; Frendi, A.; Thompson, W.; Casiano, M. J.

    2016-01-01

    This Technical Publication summarizes the work focused on the testing and analysis of sensor ports. The tasks under this contract were divided into three areas: (1) Development of an Analytical Model, (2) Conducting a Set of Experiments, and (3) Obtaining Computational Solutions. Results from the experiment using both short and long sensor ports were obtained using harmonic, random, and frequency sweep plane acoustic waves. An amplification factor of the pressure signal between the port inlet and the back of the port is obtained and compared to models. Comparisons of model and experimental results showed very good agreement.

  5. Reproducibility and validity of the DynaPort KneeTest

    NARCIS (Netherlands)

    Mokkink, L.B.; Terwee, C.B.; Slikke, van der R.M.; Lummel, van R.C.; Benink, R.J.; Bouter, L.M.; Vet, de H.C.W.

    2005-01-01

    OBJECTIVE: To determine the reproducibility and validity of the DynaPort KneeTest, a performance-based test that measures quality of movement of patients undergoing total knee replacement (TKR). METHODS: A total of 92 patients with osteoarthritis (OA) of the knee performed the KneeTest twice on the

  6. Developing a testing tool for a port terminal operating system

    OpenAIRE

    Perič, Miran

    2011-01-01

    This thesis describes the approach for development of a testing tool which simulates the terminal operating system. Main result of the thesis is presentation of the approach for the development and operation of the application, which was developed in C# programming language. The application communicates with the port information system by messages exchange. Data is stored on a database. With the support of the application we can test the port information system before of future implem...

  7. Main maintenance operations for Test Blanket Systems in ITER TBM port cells

    Energy Technology Data Exchange (ETDEWEB)

    Pascal, R., E-mail: romain.pascal@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Cortes, P.; Friconneau, J.-P.; Giancarli, L.M.; Gotewal, K.K.; Iseli, M.; Kim, B.Y.; Levesy, B.; Martins, J.-P.; Merola, M. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Nevière, J.-C. [Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Patisson, L. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Siarras, A. [Sogetti, Parc de la Duranne, 13857 Aix-en-Provence (France); Tesini, A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2013-10-15

    Highlights: • The Test Blanket System components layout in Port Cell room is described. • The maintenance of the two Test Blanket Systems in ITER port cell is addressed. • The overall replacement/maintenance strategy is defined. • The main maintenance tasks of the systems are discussed. • The maintenance strategy and required tools are presented. -- Abstract: Each Test Blanket System in ITER is formed by an in-vessel component, the Test Blanket Module, and several associated ancillary systems (coolant and Tritium systems, instrumentation and control systems). The paper describes the overall replacement/maintenance strategy and the main maintenance tasks that have to be considered in the design of the systems. It shows that there are no critical issues.

  8. HIV/AIDS testing at ports of entry in China.

    Science.gov (United States)

    Lai, Dejian; Hwang, Lu-Yu; Beasley, R Palmer

    2011-05-01

    In 2007 the Chinese government issued regulations requiring HIV/AIDS testing for Chinese citizens returning at ports of entry if they had resided outside China for 1 year or longer. Three years after publication and partial implementation of the regulations, the Chinese government decided to eliminate compulsory HIV/AIDS testing of returning Chinese. We examine the history of China's HIV/AIDS testing regulations on entry-exit populations, showing how China has gradually altered its policy. As of December 2010, the policy of compulsory HIV/AIDS testing of returning Chinese has been abandoned; however, the regulations still compel HIV/AIDS testing for other groups inside China. Our review sheds new light on the dynamics of regulatory changes in the last 3 years. The Chinese experience that we observed may provide useful insights for policymakers in other parts of the world.

  9. Construction of a test platform for Test Blanket Module (TBM) systems integration and maintenance in ITER Port Cell #16

    Energy Technology Data Exchange (ETDEWEB)

    Vála, Ladislav, E-mail: ladislav.vala@cvrez.cz [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Reungoat, Mathieu, E-mail: mathieu.reungoat@cvrez.cz [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Vician, Martin [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Poitevin, Yves; Ricapito, Italo; Zmitko, Milan; Panayotov, Dobromir [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain)

    2015-10-15

    Highlights: • A non-nuclear, full size facility – TBM platform – is under construction in CVR. • It is designed for tests, optimization and validation of TBS maintenance operations. • It will allow testing and validation of specific maintenance tools and RH equipment. • It reproduces ITER Port Cell #16, as well as the TBS interfaces and main equipment. • The TBM platform will be available for full operation in the first half of 2016. - Abstract: This paper describes a project of a non-nuclear, 1:1 scale testing platform dedicated to tests, optimization and validation of integration and maintenance operations for the European TBM systems in the ITER Port Cell #16. This TBM platform is currently under construction in Centrum výzkumu Řež, Czech Republic. The facility is realized within the scope of the SUSEN project and its full operation is foreseen in the first half of 2016.

  10. SU-E-T-243: Design of a Novel Testing Port for Radiation Protection and Shielding Measurements

    International Nuclear Information System (INIS)

    Tanny, S; Parsai, E; Harrell, D; Noller, J; Chopra, M

    2015-01-01

    Purpose: The majority of radiation shielding research utilizes Monte Carlo simulation because of the difficulty in eliminating secondary radiations from measurements. We have designed a test port into a primary barrier of our newest vault to allow for shielding measurements while ensuring adequate protection to the public and staff during normal machine operation. This port allows for measurement of attenuation values of shielding materials, differential dose albedos, and radiation scatter fractions. Methods: The vault design utilized the maze as part of a compound primary barrier. The test port is contained within the maze and is centered along isocenter. The inner 30 cm has a 20×20 cm 2 opening, while the remaining length has a 30×30 cm 2 opening. The block that contains the port has a density of 200 pcf to minimize internal scatter. The 30×30 cm 2 opening is occupied by removable 215 pcf concrete blocks. The innermost and outermost blocks activate an interlock wired into the beam-enable loop. This disallows beam-on in treatment mode if the interlock isn’t closed. The interlock can be overridden in service mode, or by-passed via an override switch in case of circuit failure. Results: The test port was installed in August. The beam is disabled when the interlock is tripped. Measurements taken when the primary beam is not incident on the port are indistinguishable from background. Ambient dose levels surrounding the vault with the designed shielding blocks in place are all within allowable limits for occupational workers. Conclusions: We have designed and installed a unique testing port for radiation protection and shielding measurements. This port is appropriately interlocked and designed to mitigate any risks of incidental exposure to staff or members of the public. The test port design allows measurements with “good geometry” and efficient removal of contaminating sources of radiation present in many shielding measurements. Daniel Harrell and Jim Noller

  11. Progress in the integration of Test Blanket Systems in ITER equatorial port cells and in the interfaces definition

    Energy Technology Data Exchange (ETDEWEB)

    Pascal, R., E-mail: romain.pascal@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Beloglazov, S.; Bonagiri, S. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Commin, L. [CEA, IRFM, Cadarache (France); Cortes, P.; Giancarli, L.M.; Gliss, C.; Iseli, M.; Lanza, R.; Levesy, B.; Martins, J.-P. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Neviere, J.-C. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Patisson, L.; Plutino, D.; Shu, W. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Swami, H.L. [Institute for Plasma Research, Bhat, Gandhinagar 382428 (India)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer The design integration of two test blanket systems in ITER port cell is addressed. Black-Right-Pointing-Pointer Definition of interfaces of TBSs with building and other ITER systems is done. Black-Right-Pointing-Pointer Designs of pipe forest, bioshield plug and ancillary equipment unit are described. Black-Right-Pointing-Pointer The maintenance of the two test blanket systems in ITER port cell is considered. Black-Right-Pointing-Pointer The management of the heat and tritium releases in the TBM port cell is described. - Abstract: In the framework of the TBM Program, three ITER vacuum vessel equatorial ports (no. 16, no. 18 and no. 02) have been allocated for the testing of up to six mock-ups of six different DEMO tritium breeding blankets. Each one is called a Test Blanket System (TBS). A TBS consists mainly of the Test Blanket Module (TBM), the in-vessel component facing the plasma, and several ancillary systems, in particular the cooling system and the tritium extraction system. Each port accommodates two TBMs and therefore the two TBSs have to share the corresponding port cell. This paper deals with the design integration aspects of the two TBSs in each port cell performed at ITER Organization (IO) with the corresponding definition of interfaces with other ITER systems. The performed activities have raised several issues that are discussed in the paper and for which design solutions are proposed.

  12. Testing market informational efficiency of Constanta port operators

    Science.gov (United States)

    Roşca, E.; Popa, M.; Ruscă, F.; Burciu, Ş.

    2015-11-01

    The Romanian capital market is still an emergent one. Following the mass- privatization process and the private investments, three of the most important handling and storage companies acting in Constantza Port (OIL Terminal, Comvex and SOCEP) are listed on Romanian Stock Exchange. The paper investigates their evolution on the market, identifying the expected rate of return and the components of the shares risk (specific and systematic). Also, the price evolution could be analyzed through the informational efficiency which instantly reflects the price relevance. The Jarque-Bera normality test regarding the shares return rate distribution and the Fama test for the informational efficiency are completed for each company. The market price model is taken into consideration for price forecasting, computing the return rate auto-correlations. The results are subject of interpretation considering additional managerial and financial information of the companies’ activity.

  13. Testing optimization sequence for the beam port facility of PSBR

    International Nuclear Information System (INIS)

    Bekar, K.B.; Azmy, Y.Y.; Unlu, K.

    2005-01-01

    We present preliminary testing results of the modular code package prepared for the size and shape optimization of the beam tube device of the beam port facility at the Penn State Breazeale Reactor (PSBR). In the test cases, using the Min-max algorithm as an optimizer and multidimensional, neutral particle transport code TORT as a transport solver in the physics calculation, we optimize the shape of the D 2 O moderator of the beam tube device. We illustrate the modular nature of the optimization package, validation tests of the physics model, and preliminary optimization calculation via the whole code package. Results obtained so far indicate the drum-shaped D 2 O moderator tank is over-designed in size and does not possess the almost hemi-spherical optimal shape computed by our new package. (authors)

  14. Three-Dimensional Model Test Study of Modified Caisson Breakwater at Port of Castellon, Spain

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen Harck; Andersen, Thomas Lykke

    caisson breakwater at Port of Castellon, Spain, tested earlier (Nørgaard & Lykke Andersen, 2013). Associate Prof. Thomas Lykke Andersen and M.Sc. Jørgen Quvang Harck Nørgaard were in charge of the model tests. Engineer assistant Niels Drustrup assisted in the laboratory with the construction...

  15. Model Test Study of the Breakwater at the Dubai Port Terminal in Callao, Peru

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Burcharth, Hans F.

    This report deals with a two-dimensional model test study of the new breakwater for the Dubai Port terminal in Callao, Peru. Two cross-sections were tested namely the outer part of the breakwater (Section C) and a cross-section at the container terminal area (Section A). The length scale used...

  16. Attributes of diagnostic tests to increase uptake of dual testing for syphilis and HIV in Port-au-Prince, Haiti.

    Science.gov (United States)

    Bristow, Claire C; Lee, Sung-Jae; Severe, Linda; William Pape, Jean; Javanbakht, Marjan; Scott Comulada, Warren; Klausner, Jeffrey D

    2017-03-01

    Introduction Syphilis and HIV screening is highly recommended for pregnant women and those at risk for infection. We used conjoint analysis to identify factors associated with testing preferences for HIV and syphilis infection. Methods We recruited 298 men and women 18 years and over seeking testing or care at GHESKIO (Haitian Study Group for Kaposi's Sarcoma and Opportunistic Infections) clinics. We created eight hypothetical dual HIV-syphilis test profiles varying across six dichotomous attributes. Participants were asked to rate each profile using Likert preference scales. An impact score was generated for each attribute by taking the difference between the preference scores for the preferred and non-preferred level of each attribute. Two-sided one-sample t-test was used to generate p values. Results Of 298 study participants, 61 (20.5%) were male. Of 237 females, 49 (20.7%) were pregnant. Cost (free vs. US$4; p syphilis testing preferences for this study sample in Port-au-Prince prioritized cost, single fingerprick, laboratory-based testing and timeliness.

  17. Tritium and heat management in ITER Test Blanket Systems port cell for maintenance operations

    Energy Technology Data Exchange (ETDEWEB)

    Giancarli, L.M., E-mail: luciano.giancarli@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Cortes, P.; Iseli, M.; Lepetit, L.; Levesy, B. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Livingston, D. [Frazer-Nash Consultancy Ltd., Stonebridge House, Dorking Business Park, Dorking, Surrey RH4 1HJ (United Kingdom); Nevière, J.C. [Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Pascal, R. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Ricapito, I. [Fusion for Energy, Josep Pla, 2, Torres Diagonal Litoral B3, Barcelona E-08019 (Spain); Shu, W. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Wyse, S. [Frazer-Nash Consultancy Ltd., Stonebridge House, Dorking Business Park, Dorking, Surrey RH4 1HJ (United Kingdom)

    2014-10-15

    Highlights: •The ITER TBM Program is one of the ITER missions. •We model a TBM port cell with CFD to optimize the design choices. •The heat and tritium releases management in TBM port cells has been optimized. •It is possible to reduce the T-concentration below one DAC in TBM port cells. •The TBM port cells can have human access within 12 h after shutdown. -- Abstract: Three ITER equatorial port cells are dedicated to the assessment of six different designs of breeding blankets, known as Test Blanket Modules (TBMs). Several high temperature components and pipework will be present in each TBM port cell and will release a significant quantity of heat that has to be extracted in order to avoid the ambient air and concrete wall temperatures to exceed allowable limits. Moreover, from these components and pipes, a fraction of the contained tritium permeates and/or leaks into the port cell. This paper describes the optimization of the heat extraction management during operation, and the tritium concentration control required for entry into the port cell to proceed with the required maintenance operations after the plasma shutdown.

  18. Two-Dimensional Model Test Study of New Western Breakwater Proposal for Port of Hanstholm

    OpenAIRE

    Eldrup, Mads Røge; Andersen, Thomas Lykke

    2016-01-01

    The present report presents results from a two-dimensional model test study carried out at Aalborg University in December 2016 with the proposed trunk section for the new western breakwater in Port of Hanstholm. The objectives of the model tests were to study the stability of the armour layer, toe erosion, overtopping and transmission. The scale used for the model tests was 1:61.5. Unless otherwise specified all values given in this report are prototype values converted from the model to prot...

  19. Two-Dimensional Model Test Study of New Western Breakwater Proposal for Port of Hanstholm

    DEFF Research Database (Denmark)

    Eldrup, Mads Røge; Andersen, Thomas Lykke

    The present report presents results from a two-dimensional model test study carried out at Aalborg University in December 2016 with the proposed trunk section for the new western breakwater in Port of Hanstholm. The objectives of the model tests were to study the stability of the armour layer, toe...... erosion, overtopping and transmission. The scale used for the model tests was 1:61.5. Unless otherwise specified all values given in this report are prototype values converted from the model to prototype according to the Froude model law....

  20. Three-Dimensional Model Test Verification of the New Cubipod Armoured Western Breakwater for Port of Hanstholm

    DEFF Research Database (Denmark)

    Eldrup, Mads Røge; Andersen, Thomas Lykke

    The present report presents results from a three-dimensional model test study carried out at Aalborg University in January 2018 with the new western breakwater in Port of Hanstholm as proposed by the contractor Aarsleff and their consultant Cowi. The objectives of the model tests were to study th...

  1. Clinical Tests of Ultra-Low Vision Used to Evaluate Rudimentary Visual Perceptions Enabled by the BrainPort Vision Device.

    Science.gov (United States)

    Nau, Amy; Bach, Michael; Fisher, Christopher

    2013-01-01

    We evaluated whether existing ultra-low vision tests are suitable for measuring outcomes using sensory substitution. The BrainPort is a vision assist device coupling a live video feed with an electrotactile tongue display, allowing a user to gain information about their surroundings. We enrolled 30 adult subjects (age range 22-74) divided into two groups. Our blind group included 24 subjects ( n = 16 males and n = 8 females, average age 50) with light perception or worse vision. Our control group consisted of six subjects ( n = 3 males, n = 3 females, average age 43) with healthy ocular status. All subjects performed 11 computer-based psychophysical tests from three programs: Basic Assessment of Light Motion, Basic Assessment of Grating Acuity, and the Freiburg Vision Test as well as a modified Tangent Screen. Assessments were performed at baseline and again using the BrainPort after 15 hours of training. Most tests could be used with the BrainPort. Mean success scores increased for all of our tests except contrast sensitivity. Increases were statistically significant for tests of light perception (8.27 ± 3.95 SE), time resolution (61.4% ± 3.14 SE), light localization (44.57% ± 3.58 SE), grating orientation (70.27% ± 4.64 SE), and white Tumbling E on a black background (2.49 logMAR ± 0.39 SE). Motion tests were limited by BrainPort resolution. Tactile-based sensory substitution devices are amenable to psychophysical assessments of vision, even though traditional visual pathways are circumvented. This study is one of many that will need to be undertaken to achieve a common outcomes infrastructure for the field of artificial vision.

  2. The SimPort-based simulators and distributed control systems development, upgrade and testing

    International Nuclear Information System (INIS)

    Danilov, Victor A.; Yanushevich, Dmitry I.; Zenkov, Andrey D.

    2004-01-01

    This paper describes the SimPort computer technology application experience related with power plant simulators and Distributed Control System (DCS) emulators development. The paper presents basic characteristics of the SimPort as a Windows NT-based implementation variety of the developed in RRC 'Kurchatov Institute' math modeling and simulator creation AIS technology. The new approaches and benefits of using simulation for DCS development and, especially upgrade, testing and on plant tuning are presented in the paper briefly. The DCS-inclusive power plant SimPort-based simulators are also considered. The DCS emulation principal problems, solutions and the experience-based DCS emulators development methodology are presented also. The presented technology quality and efficiency as well as presented DCS emulation problem solutions were verified by the smallest power plant full scope computer simulators development man-hours (at least twice lower in comparison with the similar simulators) in combination with the simulators correspondence to the standard and the best quality of nuclear power plant simulators. (Author)

  3. Shutdown dose rate analysis of European test blanket modules shields in ITER Equatorial Port #16

    Energy Technology Data Exchange (ETDEWEB)

    Juárez, Rafael, E-mail: rjuarez@ind.uned.es [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Sauvan, Patrick; Perez, Lucia [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Panayotov, Dobromir; Vallory, Joelle; Zmitko, Milan; Poitevin, Yves [Fusion for Energy (F4E), Torres Diagonal Litoral B3, Josep Pla 2, Barcelona 08019 (Spain); Sanz, Javier [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain)

    2016-11-01

    Highlights: • Nuclear analysis for European TBMs and shields, in ITER Equatorial Port #16, has been conducted in support of the ‘Concept Design Review’ from ITER. • The objective of the work is the characterization of the Shutdown Dose Rates at Equatorial Port #16 interspace. • The role played by the TBM and TBM shields, the equatorial port gaps and the vacuum vessel permeation, in terms of neutron flux transmission is assessed. • The role played by the TBM, TBM shields, Port Plug Frame, Pipe Forest and the machine in terms of activation is also investigated. - Abstract: ‘Fusion for Energy’ (F4E) is designing, developing, and implementing the European Helium-Cooled Lead-Lithium (HCLL) and Helium-Cooled Pebble-Bed (HCPB) Test Blanket Systems (TBSs) for ITER (Nuclear Facility INB-174). An essential element of the Conceptual Design Review (CDR) of these TBSs is the demonstration of capability of Test Blanket Modules (TBM) and their shields to fulfil their function and comply with the design requirements. One of the TBM shields highly relevant design aspects is the project target for shutdown dose rates (SDDR) in the interspace. We investigated two functions of the TBMs and TBM shields—the neutron flux attenuation along the shields, and the reduction of the activation of the components contributing to SDDR. It is shown that TBMs and TBM shields reduce significantly the neutron flux in the port plug (PP). In terms of neutron flux attenuation, the TBM shield provides sufficient neutron flux reduction, being responsible for 5 × 10{sup 6} n/cm{sup 2} s at port interspace, while the EPP gaps and BSM gaps are responsible for 5 × 10{sup 7} n/cm{sup 2} s each. When considering closed upper, lower and lateral neighbour equatorial ports (thus, excluding the cross-talk between ports), a SDDR of 121 μSv/h averaged near the port closure flange was obtained, out of which, only 4 μSv/h are due to the activation of TBMs and TBM shields. Maximum SDDR in the range

  4. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    Science.gov (United States)

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  5. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    Science.gov (United States)

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  6. Two-Dimensional Model Test Verification of the New Cubipod Armoured Western Breakwater for the Port of Hanstholm

    DEFF Research Database (Denmark)

    Eldrup, Mads Røge; Andersen, Thomas Lykke

    The present report presents results from a two-dimensional model test study carried out at Aalborg University in December 2017 with the proposed trunk section for the new cubipod armoured western breakwater in Port of Hanstholm as proposed by the contractor Aarsleff and their consultant Cowi....... The objectives of the model tests were to study the stability of the armour layer, toe erosion, overtopping and transmission. The scale used for the model tests was 1:44.6. Initially the model was created on a scale 1:47, but model was adapted to 1:44.6 due to a mismatch in density of rented cupipods. Unless...

  7. Light-emitting device test systems

    Science.gov (United States)

    McCord, Mark; Brodie, Alan; George, James; Guan, Yu; Nyffenegger, Ralph

    2018-01-23

    Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.

  8. NET test blanket design and remote maintenance

    International Nuclear Information System (INIS)

    Holloway, C.; Hubert, P.

    1991-01-01

    The NET machine has three horizontal ports reserved for testing tritium breeding blanket designs during the physics phase and possibly five during the technology phase. The design of the ports and test blankets are modular to accept a range of blanket options, provide radiation shielding and allow routine replacement. Radiation levels during replacement or maintenance require that all operations must be carried out remotely. The paper describes the problems overcome in providing a port design which includes attachment to the vacuum vessel with double vacuum seals, an integrated cooled first wall and support guides for the test blanket module. The method selected to remotely replace the test module whilst controlling the spread of contamination is also adressed. The paper concludes that the provisions of a test blanket facility based on the NET machine design is feasible. (orig.)

  9. Second Line of Defense, Port of Buenos Aires and Exolgan Container Terminal Operational Testing and Evaluation Plan, Buenos Aires, Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Bryan W.

    2012-08-23

    The Office of the Second Line of Defense (SLD) Megaports project team for Argentina will conduct operational testing and evaluation (OT&E) at Exolgan Container Terminal at the Port of Dock Sud from July 16-20, 2012; and at the Port of Buenos Aires from September 3-7, 2012. SLD is installing radiation detection equipment to screen export, import, and transshipment containers at these locations. The purpose of OT&E is to validate and baseline an operable system that meets the SLD mission and to ensure the system continues to perform as expected in an operational environment with Argentina Customs effectively adjudicating alarms.

  10. Interpretation of the lime column penetration test

    International Nuclear Information System (INIS)

    Liyanapathirana, D S; Kelly, R B

    2010-01-01

    Dry soil mix (DSM) columns are used to reduce the settlement and to improve the stability of embankments constructed on soft clays. During construction the shear strength of the columns needs to be confirmed for compliance with technical assumptions. A specialized blade shaped penetrometer known as the lime column probe, has been developed for testing DSM columns. This test can be carried out as a pull out resistance test (PORT) or a push in resistance test (PIRT). The test is considered to be more representative of average column shear strength than methods that test only a limited area of the column. Both PORT and PIRT tests require empirical correlations of measured resistance to an absolute measure of shear strength, in a similar manner to the cone penetration test. In this paper, finite element method is used to assess the probe factor, N, for the PORT test. Due to the large soil deformations around the probe, an Arbitrary Lagrangian Eulerian (ALE) based finite element formulation has been used. Variation of N with rigidity index and the friction at the probe-soil interface are investigated to establish a range for the probe factor.

  11. Wave Reflection Model Tests

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Larsen, Brian Juul

    The investigation concerns the design of a new internal breakwater in the main port of Ibiza. The objective of the model tests was in the first hand to optimize the cross section to make the wave reflection low enough to ensure that unacceptable wave agitation will not occur in the port. Secondly...

  12. Blanket testing in NET

    International Nuclear Information System (INIS)

    Chazalon, M.; Daenner, W.; Libin, B.

    1989-01-01

    The testing stages in NET for the performance assessment of the various breeding blanket concepts developed at the present time in Europe for DEMO (LiPb and ceramic blankets) and the requirements upon NET to perform these tests are reviewed. Typical locations available in NET for blanket testing are the central outboard segments and the horizontal ports of in-vessel sectors. These test positions will be connectable with external test loops. The number of test loops (helium, water, liquid metal) will be such that each major class of blankets can be tested in NET. The test positions, the boundary conditions and the external test loops are identified and the requirements for test blankets are summarized (author). 6

  13. Spread Spectrum Receiver Electromagnetic Interference (EMI) Test Guide

    Science.gov (United States)

    Wheeler, M. L.

    1998-01-01

    The objective of this test guide is to document appropriate unit level test methods and techniques for the performance of EMI testing of Direct Sequence (DS) spread spectrum receivers. Consideration of EMI test methods tailored for spread spectrum receivers utilizing frequency spreading, techniques other than direct sequence (such as frequency hopping, frequency chirping, and various hybrid methods) is beyond the scope of this test guide development program and is not addressed as part of this document EMI test requirements for NASA programs are primarily developed based on the requirements contained in MIL-STD-46 1 D (or earlier revisions of MIL-STD-46 1). The corresponding test method guidelines for the MIL-STD-461 D tests are provided in MIL-STD-462D. These test methods are well documented with the exception of the receiver antenna port susceptibility tests (intermodulation, cross modulation, and rejection of undesired signals) which must be tailored to the specific type of receiver that is being tested. Thus, test methods addressed in this guide consist only of antenna port tests designed to evaluate receiver susceptibility characteristics. MIL-STD-462D should be referred for guidance pertaining to test methods for EMI tests other than the antenna port tests. The scope of this test guide includes: (1) a discussion of generic DS receiver performance characteristics; (2) a summary of S-band TDRSS receiver operation; (3) a discussion of DS receiver EMI susceptibility mechanisms and characteristics; (4) a summary of military standard test guidelines; (5) recommended test approach and methods; and (6) general conclusions and recommendations for future studies in the area of spread spectrum receiver testing.

  14. Wounds caused by contact with muzzle-lift relief ports (Mag-Na-Port).

    Science.gov (United States)

    Rogers, D R; Shem, R J

    1992-12-01

    Fan-shaped stippled burns were produced on the skin when a revolver whose barrel had been modified by the Mag-Na-Port process was fired twice with the side of the muzzle in contact. A grazing wound was produced by one bullet, and an oblique entry was produced by the other. The characteristics of Mag-Na-Port wounds and test shots are described, and these are compared with test shots from two other higher power revolvers.

  15. 40 CFR 63.547 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.547 Section 63.547... Hazardous Air Pollutants from Secondary Lead Smelting § 63.547 Test methods. (a) The following test methods...), and 63.545(e): (1) Method 1 shall be used to select the sampling port location and the number of...

  16. Construction and Testing of a 21 GHz Ceramic Based Power Extractor

    CERN Document Server

    Newsham, D; Carron, G; Döbert, Steffen; Gai, W; Konecny, R; Liu, W; Smirnov, A Yu; Thorndahl, L; Wilson, Ian H; Wuensch, Walter; Yu, D

    2003-01-01

    A ceramic based power extractor [1] operating at 21 GHz was built by DULY Research Inc. and tested at CTF2, the CERN Linear Collider (CLIC) Test Facility. The structure includes a ceramic extractor section, a 2-output-port, circular-to-rectangular waveguide coupler, and a 3-port rectangular waveguide combiner that provides for a single output waveguide. Results of cold tests and full beam tests are presented and compared with theoretical and numerical models.

  17. Injecting Errors for Testing Built-In Test Software

    Science.gov (United States)

    Gender, Thomas K.; Chow, James

    2010-01-01

    Two algorithms have been conceived to enable automated, thorough testing of Built-in test (BIT) software. The first algorithm applies to BIT routines that define pass/fail criteria based on values of data read from such hardware devices as memories, input ports, or registers. This algorithm simulates effects of errors in a device under test by (1) intercepting data from the device and (2) performing AND operations between the data and the data mask specific to the device. This operation yields values not expected by the BIT routine. This algorithm entails very small, permanent instrumentation of the software under test (SUT) for performing the AND operations. The second algorithm applies to BIT programs that provide services to users application programs via commands or callable interfaces and requires a capability for test-driver software to read and write the memory used in execution of the SUT. This algorithm identifies all SUT code execution addresses where errors are to be injected, then temporarily replaces the code at those addresses with small test code sequences to inject latent severe errors, then determines whether, as desired, the SUT detects the errors and recovers

  18. Probabilistic model of bridge vehicle loads in port area based on in-situ load testing

    Science.gov (United States)

    Deng, Ming; Wang, Lei; Zhang, Jianren; Wang, Rei; Yan, Yanhong

    2017-11-01

    Vehicle load is an important factor affecting the safety and usability of bridges. An statistical analysis is carried out in this paper to investigate the vehicle load data of Tianjin Haibin highway in Tianjin port of China, which are collected by the Weigh-in- Motion (WIM) system. Following this, the effect of the vehicle load on test bridge is calculated, and then compared with the calculation result according to HL-93(AASHTO LRFD). Results show that the overall vehicle load follows a distribution with a weighted sum of four normal distributions. The maximum vehicle load during the design reference period follows a type I extremum distribution. The vehicle load effect also follows a weighted sum of four normal distributions, and the standard value of the vehicle load is recommended as 1.8 times that of the calculated value according to HL-93.

  19. Full scale test platform for European TBM systems integration and maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Vála, Ladislav, E-mail: ladislav.vala@cvrez.cz; Reungoat, Mathieu; Vician, Martin

    2016-11-01

    Highlights: • A platform for EU-TBS maintenance and integration tests is described. • Its modular design allows adaptation to non-EU TBSs. • Assembling of the facility will be followed by initial tests in 2016. - Abstract: This article deals with description and current status of a project of a non-nuclear, full size (1:1 scale) test platform dedicated to tests, optimization and validation of integration and maintenance operations for the European TBM systems in the ITER port cell #16. The facility called TBM platform reproduces the ITER port cell #16 and port interspace with all the relevant interfaces and mock-ups of the corresponding main components. Thanks to the modular design of the platform, it is possible to adapt or change completely the interfaces in the future if needed or required according to the updated configuration of TBSs. In the same way, based on customer requirements, it will be possible to adapt the interfaces and piping inside the mock-ups in order to represent also the other, non-EU configurations of TBM systems designed for port cells #02 and #18. Construction of this test platform is realized and funded within the scope of the SUSEN project.

  20. ITER diagnostics: Maintenance and commissioning in the hot cell test bed

    International Nuclear Information System (INIS)

    Walker, C.I.; Barnsley, R.; Costley, A.E.; Gottfried, R.; Haist, B.; Itami, K.; Kondoh, T.; Loesser, G.D.; Palmer, J.; Sugie, T.; Tesini, A.; Vayakis, G.

    2005-01-01

    In-vessel diagnostic equipment in ITER integrated in six equatorial and 12 upper ports, 16 divertor cassettes and five lower ports is designed to be removed in modules and then repaired, tested and commissioned in the same location at the ITER hot cell. The repair requirements and tests on these components are described along with design features that facilitate repair. The testing establishes the repair strategy, qualifies the refurbishment work and finally checks the mechanical and diagnostic function before the return of the modules. At the hot cell, a dummy port is provided for tests of mechanical and vacuum integrity as well as commissioning of the diagnostic equipment. The scope of the hot cell maintenance and commissioning activities is summarised and an overview of the integration of the diagnostic equipment is given

  1. Large expansion joint movement test; Teste de movimentacao de juntas de expansao de grande porte

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros, Jorivaldo; Veiga, Jordana Luiza Barbosa da Costa [PETROBRAS, Rio de Janeiro, RJ (Brazil); Veiga, Jose Carlos [Teadit, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    This paper show the results obtained in a movement test realized on metallic bellows expansion joints used in the turbo expander duct system. A test device was developed. For dada acquisition a dynamometer was used and the tests were performed on gimbal expansion joints type. The joints were pressurized with water during the test. Data acquisition was realized at the design, operation and room pressure. The expansion joints were tested rotating them to the design angular movement of 3 deg and 6 deg degrees. The reactions for each degree of movement were recorded during loading and unloading. The tests confirmed that the expansion joints presented no-interference from construction, which configure in an adequate acceptance proceeding. It was noted the influence of internal pressure on reaction forces during expansion joints movements, these forces are not taken into consideration on theoretical calculations of EJMA design equations. The influence of friction on expansion joints hinges are significant and shall be considered on piping design and mitigated using friction reduction devices. (author)

  2. SMART Rotor Development and Wind Tunnel Test

    Science.gov (United States)

    2009-09-01

    amplifier and control system , and data acquisition, processing, and display systems . Boeing�s LRTS (Fig. 2), consists of a sled structure that...Support Test Stand Sled Tail Sting Outrigger Arm Figure 2: System integration test at whirl tower Port Rotor Balance Main Strut Flap Tail...demonstrated. Finally, the reliability of the flap actuation system was successfully proven in more than 60 hours of wind tunnel testing

  3. Dispersant testing : a study on analytical test procedures

    International Nuclear Information System (INIS)

    Fingas, M.F.; Fieldhouse, B.; Wang, Z.; Environment Canada, Ottawa, ON

    2004-01-01

    Crude oil is a complex mixture of hydrocarbons, ranging from small, volatile compounds to very large, non-volatile compounds. Analysis of the dispersed oil is crucial. This paper described Environment Canada's ongoing studies on various traits of dispersants. In particular, it describes small studies related to dispersant effectiveness and methods to improve analytical procedures. The study also re-evaluated the analytical procedure for the Swirling Flask Test, which is now part of the ASTM standard procedure. There are new and improved methods for analyzing oil-in-water using gas chromatography (GC). The methods could be further enhanced by integrating the entire chromatogram rather than just peaks. This would result in a decrease in maximum variation from 5 per cent to about 2 per cent. For oil-dispersant studies, the surfactant-dispersed oil hydrocarbons consist of two parts: GC-resolved hydrocarbons and GC-unresolved hydrocarbons. This study also tested a second feature of the Swirling Flask Test in which the side spout was tested and compared with a new vessel with a septum port instead of a side spout. This decreased the variability as well as the energy and mixing in the vessel. Rather than being a variation of the Swirling Flask Test, it was suggested that a spoutless vessel might be considered as a completely separate test. 7 refs., 2 tabs., 4 figs

  4. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  5. Cold leg condensation tests. Task C. Steam--water interaction tests

    International Nuclear Information System (INIS)

    Brodrick, J.R.; Loiselle, V.

    1974-03-01

    A report is presented of tests to determine the condensation efficiency of ECC water injected into a quality fluid mixture flowing through the cold leg. In particular, a specific objective was to determine if the mixture of ECC water and quality fluid reached thermodynamic equilibrium before exiting the cold leg. Further, the stability of the ECC water/quality fluid interaction would be assessed by interpretation of thermocouple records and utilization of a section of cold leg piping with view ports to film the interaction whenever possible. The cold leg condensation tests showed complete condensation of the 5 lbm/sec steam quality mixtures in the cold leg by the ECC water flows of the test matrix. The cold leg exit fluid temperature remained below the saturation temperature and had good agreement with the predicted cold leg outlet temperature, calculated assuming total condensation. (U.S.)

  6. Is D U Phenotype Testing A Necessity In Blood Bank Practice In ...

    African Journals Online (AJOL)

    Objective: To evaluate the necessity of Du Phenotype testing in blood bank practice in Nigeria. Design: Cross-sectional study. Setting: Three health institutions within Port Harcourt metropolis: The University of Port Harcourt Teaching Hospital, Braithewaite Memorial Hospital, Port Harcourt and Orogbum comprehensive ...

  7. Use of CFD in development of intake ports for diesel engines

    International Nuclear Information System (INIS)

    Alcenius, T.

    2002-01-01

    The design of intake ports for diesel engines is difficult due to the many competing requirements of the cylinder head design. When the concept design is completed, the typical course for verification and optimization of the port is through steady state flow testing. In the past, optimization of the port was considered a 'black art' as the final shape of the port and its performance was tied directly to the experience of the port development engineer. As CFD has been increasingly used to analyze various aspects of engine performance, an obvious area to explore is its use to predict steady state port flow performance prior to fabrication of any test hardware. A study was carried out to evaluate the usefulness of CFD in predicting steady state flow bench results and to provide insight into the fluid mechanics of the port flow to assist in the flow bench development. Port flow testing was carried out on a baseline diesel engine port for a range of valve lifts from zero to just above the maximum valve lift. This experimental test data was used to calculate flow coefficients and swirl ratios (an indicator of mean air motion in the cylinder). Subsequently, CFD models were generated that replicated the flow bench set-up. Three valve lifts across the valve lift range were chosen for the comparison. Results of the analysis were used to calculate flow coefficients and swirl ratios. Computed results were then compared to the experiments to determine their accuracy and a detailed review of the CFD results was conducted to understand the flow in the port. Modifications were made to the port from recommendations made based on the CFD results. The ports were then retested to determine the effectiveness of the recommendations. Finally, the results are discussed as to their meaning and usefulness for design programs. (author)

  8. Spatial Determinants of Import Traffic Distribution At Port Harcourt (Nigeria

    Directory of Open Access Journals (Sweden)

    Soddy I. Inyang

    2013-07-01

    Full Text Available This paper highlights the result of a study carried out to examine the Geographic determinants of import traffic distribution at the Port Harcourt Port. A substantial aspect of the study involved building a regression model to estimate import distribution from the Port. The import function was specified in log-linear form. The adequacy of the model was then tested; this, involved statistical experiments to obtain the R-squared, as well as t and f values. Further test on the adequacy of the nwdel was conducted through diagnostic exercises designed to check for inulticollinedrity and heteroscedasticity, in the data used. Results obtained show that road distance and manufacturing industries are significant Geographic determinants of import Cargo distribution at the study Port. It is therefore important to lake the two variables into account in any policy or planning exercise at Port Harcourt Port.

  9. Dual rapid lateral flow immunoassay fingerstick wholeblood testing for syphilis and HIV infections is acceptable and accurate, Port-au-Prince, Haiti.

    Science.gov (United States)

    Bristow, Claire C; Severe, Linda; Pape, Jean William; Javanbakht, Marjan; Lee, Sung-Jae; Comulada, Warren Scott; Klausner, Jeffrey D

    2016-06-18

    Dual rapid tests for HIV and syphilis infections allow for detection of HIV infection and syphilis at the point-of-care. Those tests have been evaluated in laboratory settings and show excellent performance but have not been evaluated in the field. We evaluated the field performance of the SD BIOLINE HIV/Syphilis Duo test in Port-au-Prince, Haiti using whole blood fingerprick specimens. GHESKIO (Haitian Study Group for Kaposi's Sarcoma and Opportunistic Infections) clinic attendees 18 years of age or older were invited to participate. Venipuncture blood specimens were used for reference testing with standard commercially available tests for HIV and syphilis in Haiti. The sensitivity and specificity of the Duo test compared to the reference standard were calculated. The exact binomial method was used to determine 95 % confidence intervals (CI). Of 298 study participants, 237 (79.5 %) were female, of which 49 (20.7 %) were pregnant. For the HIV test component, the sensitivity and specificity were 99.2 % (95 % CI: 95.8 %, 100 %) and 97.0 % (95 % CI: 93.2 %, 99.0 %), respectively; and for the syphilis component were 96.5 % (95 % CI: 91.2 %, 99.0 %) and 90.8 % (95 % CI: 85.7 %, 94.6 %), respectively. In pregnant women, the sensitivity and specificity of the HIV test component were 93.3 % (95 % CI: 68.0 %, 99.8 %) and 94.1 % (95 % CI: 80.3 %, 99.3 %), respectively; and for the syphilis component were 100 % (95 % CI:81.5 %, 100 %) and 96.8 % (95 % CI:83.3 %, 99.9 %), respectively. The Standard Diagnostics BIOLINE HIV/Syphilis Duo dual test performed well in a field setting in Haiti and should be considered for wider use.

  10. 40 CFR Appendix A-2 to Part 60 - Test Methods 2G through 3C

    Science.gov (United States)

    2010-07-01

    ... Velocity Decay Near the Stack Wall Method 3—Gas analysis for the determination of dry molecular weight... a tester facing a test port in a vertical stack, the pitch component of flow is the vector of flow moving from the center of the stack toward or away from that test port. The pitch angle is the angle...

  11. Infrared source test

    Energy Technology Data Exchange (ETDEWEB)

    Ott, L.

    1994-11-15

    The purpose of the Infrared Source Test (IRST) is to demonstrate the ability to track a ground target with an infrared sensor from an airplane. The system is being developed within the Advance Technology Program`s Theater Missile Defense/Unmanned Aerial Vehicle (UAV) section. The IRST payload consists of an Amber Radiance 1 infrared camera system, a computer, a gimbaled mirror, and a hard disk. The processor is a custom R3000 CPU board made by Risq Modular Systems, Inc. for LLNL. The board has ethernet, SCSI, parallel I/O, and serial ports, a DMA channel, a video (frame buffer) interface, and eight MBytes of main memory. The real-time operating system VxWorks has been ported to the processor. The application code is written in C on a host SUN 4 UNIX workstation. The IRST is the result of a combined effort by physicists, electrical and mechanical engineers, and computer scientists.

  12. A PC parallel port button box provides millisecond response time accuracy under Linux.

    Science.gov (United States)

    Stewart, Neil

    2006-02-01

    For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.

  13. Non-Price Competition in the Port Sector: A Case Study of Ports in Turkey

    Directory of Open Access Journals (Sweden)

    Soner Esmer

    2016-03-01

    Full Text Available Although the port sector has been facing increasing competition, there is limited research on how ports compete using non-price competition strategies. There are a few studies on non-price competition in the port sector. However they mainly focus on the marketing aspect. This paper seeks to fill this gap in the literature, especially from a combined marketing-economic perspective. Especially the paper's main objective is to identify the determinants of non-price competition in the port sector and evaluate their effect on various aspects of non-price competition. We start with a general conceptual framework to explain how competition in the sector can be affected by various factors and then propose an analytical framework on non-price competition. The analytical model is then used to support the design of a survey questionnaire. Next, hypothesis tests are conducted using exploratory factor analysis (EFA and structural equation modeling (SEM and data collected from a survey of Turkish ports. Based on the analysis results, the implications for port management and future research are also discussed.

  14. Slewing Port Jib Cranes

    Directory of Open Access Journals (Sweden)

    Boris Visočnik

    2002-09-01

    Full Text Available The paper presents slewing port cra11es with a luffing jib.The advantages of slewing port jib cranes are high lifting capacities,high speeds of re-loading and excellent mobility since theyare capable of load lifting, travelling, luffing and slewing. Thepaper gives a detailed description of their characteristics suchas the highest reached load-canying capacities, speeds of motionand accelerations. It also presents the crane assembly,driving mechanisms, loads and load cases, transport by shipsand testing of lifting capacity. As a practical example the paperpresents the slewing port jib crane with the capacity of25!15!5 tat a 27/37/40 m radius made by the Slovenian companyMetalna Maribor for the shipyard 3. Maj, Rijeka, Croatia.

  15. Integration test of ITER full-scale vacuum vessel sector

    International Nuclear Information System (INIS)

    Nakahira, M.; Koizumi, K.; Oka, K.

    2001-01-01

    The full-scale Sector Model Project, which was initiated in 1995 as one of the Large Seven R and D Projects, completed all R and D activities planned in the ITER-EDA period with the joint effort of the ITER Joint Central Team (JCT), the Japanese, the Russian Federation (RF) and the United States (US) Home Teams. The fabrication of a full-scale 18 toroidal sector, which is composed of two 9 sectors spliced at the port center, was successfully completed in September 1997 with the dimensional accuracy of ± 3 mm for the total height and total width. Both sectors were shipped to the test site in JAERI and the integration test was begun in October 1997. The integration test involves the adjustment of field joints, automatic Narrow Gap Tungsten Inert Gas (NG-TIG) welding of field joints with splice plates, and inspection of the joint by ultrasonic testing (UT), which are required for the initial assembly of ITER vacuum vessel. This first demonstration of field joint welding and performance test on the mechanical characteristics were completed in May 1998 and the all results obtained have satisfied the ITER design. In addition to these tests, the integration with the mid plane port extension fabricated by the Russian Home Team, and the cutting and re-welding test of field joints by using full-remotized welding and cutting system developed by the US Home Team, are planned as post EDA activities. (author)

  16. Integration test of ITER full-scale vacuum vessel sector

    International Nuclear Information System (INIS)

    Nakahira, M.; Koizumi, K.; Oka, K.

    1999-01-01

    The full-scale Sector Model Project, which was initiated in 1995 as one of the Large Seven ITER R and D Projects, completed all R and D activities planned in the ITER-EDA period with the joint effort of the ITER Joint Central Team (JCT), the Japanese, the Russian Federation (RF) and the United States (US) Home Teams. The fabrication of a full-scale 18 toroidal sector, which is composed of two 9 sectors spliced at the port center, was successfully completed in September 1997 with the dimensional accuracy of - 3 mm for the total height and total width. Both sectors were shipped to the test site in JAERI and the integration test was begun in October 1997. The integration test involves the adjustment of field joints, automatic Narrow Gap Tungsten Inert Gas (NG-TIG) welding of field joints with splice plates, and inspection of the joint by ultrasonic testing (UT), which are required for the initial assembly of ITER vacuum vessel. This first demonstration of field joint welding and performance test on the mechanical characteristics were completed in May 1998 and the all results obtained have satisfied the ITER design. In addition to these tests, the integration with the mid plane port extension fabricated by the Russian Home Team, and the cutting and re-welding test of field joints by using full-remotized welding and cutting system developed by the US Home Team, are planned as post EDA activities. (author)

  17. Conceptual design of a test facility for the remote handling operations of the ITER Test Blanker Modules

    International Nuclear Information System (INIS)

    Marqueta, A.; Garcia, I.; Gomez, A.; Garcia, L.; Sedano, E.; Fernandez, I.

    2012-01-01

    Conceptual Design of a test facility for the remote handling operations of the ITER Test Blanket Modules. Conditions inside a fusion reactor are incompatible with conventional manual maintenance tasks. the same applies for ancillary equipment. As a consequence, it will become necessary to turn to remote visualization and remote handling techniques, which will have in consideration the extreme conditions, both physical and operating, of ITER. Main goal of the project has been the realization of the conceptual design for the test facility for the Test Blanket Modules of ITER and their associated systems, related to the Remote Handling operations regarding the Port Cell area. Besides the definition of the operations and the specification of the main components and ancillary systems of the TBM graphical simulation have been used for the design, verification and validation of the remote handling operations. (Author)

  18. Evaluation report on CCTF Core-II reflood test second shakedown test, C2-SH2 (Run 54)

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Sugimoto, Jun; Akimoto, Hajime; Okubo, Tsutomu; Murao, Yoshio

    1985-03-01

    A low power test (the initial averaged linear power density = 1.18 kW/m) and the base case test (1.4 kW/m) were performed with the Cylindrical Core Test Facility (CCTF) at Japan Atomic Energy Research Institute, in order to study the effect of the power on the reflood phenomena. The former linear power density corresponds nearly to the scaled linear power density based on the current safety evaluation criterio. During the early period of the reflood ( 200s) the heat transfer coefficient became higher and resultantly the quench front advanced faster in the low power test. The core flooding rate was nearly identical between both tests, independently of the different power. The insensitiveness of the power to the core flooding rate was also observed in FLECHT-SET performed in the USA. A significatn large differential pressure oscillation at ECC ports was experienced in the low power test, and it may be important for the long term core cooling although it has not been taken note on the previous studies. (author)

  19. WRAP low level waste (LLW) glovebox acceptance test report

    International Nuclear Information System (INIS)

    Leist, K.J.

    1998-01-01

    In June 28, 1997, the Low Level Waste (LLW) glovebox was tested using glovebox acceptance test procedure 13031A-85. The primary focus of the glovebox acceptance test was to examine control system interlocks, display menus, alarms, and operator messages. Limited mechanical testing involving the drum ports, hoists, drum lifter, compacted drum lifter, drum tipper, transfer car, conveyors, lidder/delidder device and the supercompactor were also conducted. As of November 24, 1997, 2 of the 131 test exceptions that affect the LLW glovebox remain open. These items will be tracked and closed via the WRAP Master Test Exception Database. As part of Test Exception resolution/closure the responsible individual closing the Test Exception performs a retest of the affected item(s) to ensure the identified deficiency is corrected, and, or to test items not previously available to support testing. Test Exceptions are provided as appendices to this report

  20. W-026, transuranic waste (TRU) glovebox acceptance test report

    International Nuclear Information System (INIS)

    Leist, K.J.

    1998-01-01

    On July 18, 1997, the Transuranic (TRU) glovebox was tested using glovebox acceptance test procedure 13021A-86. The primary focus of the glovebox acceptance test was to examine control system interlocks, display menus, alarms, and operator messages. Limited mechanical testing involving the drum ports, hoists, drum lifter, compacted drum lifter, drum tipper, transfer car, conveyors, sorting table, lidder/delidder device and the TRU empty drum compactor were also conducted. As of February 25, 1998, 10 of the 102 test exceptions that affect the TRU glovebox remain open. These items will be tracked and closed via the WRAP Master Test Exception Database. As part of Test Exception resolution/closure the responsible individual closing the Test Exception performs a retest of the affected item(s) to ensure the identified deficiency is corrected, and, or to test items not previously available to support testing. Test exceptions are provided as appendices to this report

  1. WRAP low level waste (LLW) glovebox acceptance test report

    Energy Technology Data Exchange (ETDEWEB)

    Leist, K.J.

    1998-02-17

    In June 28, 1997, the Low Level Waste (LLW) glovebox was tested using glovebox acceptance test procedure 13031A-85. The primary focus of the glovebox acceptance test was to examine control system interlocks, display menus, alarms, and operator messages. Limited mechanical testing involving the drum ports, hoists, drum lifter, compacted drum lifter, drum tipper, transfer car, conveyors, lidder/delidder device and the supercompactor were also conducted. As of November 24, 1997, 2 of the 131 test exceptions that affect the LLW glovebox remain open. These items will be tracked and closed via the WRAP Master Test Exception Database. As part of Test Exception resolution/closure the responsible individual closing the Test Exception performs a retest of the affected item(s) to ensure the identified deficiency is corrected, and, or to test items not previously available to support testing. Test Exceptions are provided as appendices to this report.

  2. Nuclide transfer test device in soil

    International Nuclear Information System (INIS)

    Sakata, Yoshiyuki.

    1994-01-01

    The device comprises a pressure-proof vessel having a perforated port, a compression vessel having a sample-containing chamber with circumferential walls having a plurality of small holes being gastightly engaged to the perforated port, a mechanically pressurizing means for vertically compressing the compression chamber, a pressurizing gas supply system for supplying a pressurizing gas to compress the soil specimen in a lateral direction and a sample water-supply system for supplying sample water to the sample containing chamber. The soil sample is pressurized so that the sample water is caused to permeate by isotropic pressure due to equilibrium of vertical compression by mechanical force and lateral compression by the pressurizing gas. The transfer state of radioactive nuclides in the soil can be tested easily in a state where the sample water is caused to permeate in a vertical direction in parallel, to simulate an actual processing circumstance. Namely, since the sample water is caused to permeate to the soil sample in the pressure-proof vessel, a desired test can easily be conducted in a restricted space without undergoing influences of the kind and the dose rate of the radioactive nuclides. (N.H.)

  3. Research on variable swirl intake port for high-speed multivalve DI diesel engine. Effects of port configuration on flow characteristics and swirl generation capacity; 4 ben kogata kosoku DI diesel engine no kahen swirl kyuki port ni kansuru kenkyu. Kyuki port haichi ga ryudo tokusei to swirl seino ni oyobosu eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Kawashima, J; Ogawa, H; Tsuru, Y [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    In our previous papers, the variable swirl intake port system which can control a wide swirl ratio range (from 4 to 10) was described. This system consisted of two separate intake ports, one of them has a flow control valve for changing the swirl ratio. In this type of variable swirl system, some variations of port combination, port shape, and position can be designed. In this paper, the intake flow characteristics of various port combinations were analyzed on the basis of a steady-state air flow test and 3-dimensional computations. The results indicate that the total performance of the twin ports can be estimated from that of a single port in any kind of port combination. Some difference in flow patterns were found in a variety of port combinations even if each swirl ratio is similar. The selected port combinations in our previous study are good for a wide swirl control range. 11 refs., 9 figs., 1 tab.

  4. 40 CFR Table 4 to Subpart Zzzz of... - Requirements for Performance Tests

    Science.gov (United States)

    2010-07-01

    ..., dry basis. 2. 4SRB stationary RICE a. Reduce formaldehyde emissions i. Select the sampling port... must be at 15 percent O2, dry basis. Results of this test consist of the average of the three 1-hour or... exhaust i. Select the sampling port location and the number of traverse points; and (1) Method 1 or 1A of...

  5. Heavy-Duty Vehicle Port Drayage Drive Cycle Characterization and Development

    Energy Technology Data Exchange (ETDEWEB)

    Prohaska, Robert; Konan, Arnaud; Kelly, Kenneth; Lammert, Michael

    2016-10-06

    In an effort to better understand the operational requirements of port drayage vehicles and their potential for adoption of advanced technologies, National Renewable Energy Laboratory (NREL) researchers collected over 36,000 miles of in-use duty cycle data from 30 Class 8 drayage trucks operating at the Port of Long Beach and Port of Los Angeles in Southern California. These data include 1-Hz global positioning system location and SAE J1939 high-speed controller area network information. Researchers processed the data through NREL's Drive-Cycle Rapid Investigation, Visualization, and Evaluation tool to examine vehicle kinematic and dynamic patterns across the spectrum of operations. Using the k-medoids clustering method, a repeatable and quantitative process for multi-mode drive cycle segmentation, the analysis led to the creation of multiple drive cycles representing four distinct modes of operation that can be used independently or in combination. These drive cycles are statistically representative of real-world operation of port drayage vehicles. When combined with modeling and simulation tools, these representative test cycles allow advanced vehicle or systems developers to efficiently and accurately evaluate vehicle technology performance requirements to reduce cost and development time while ultimately leading to the commercialization of advanced technologies that meet the performance requirements of the port drayage vocation. The drive cycles, which are suitable for chassis dynamometer testing, were compared to several existing test cycles. This paper presents the clustering methodology, accompanying results of the port drayage duty cycle analysis and custom drive cycle creation.

  6. Starting manufacturing phase of ITER upper ports

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yuri, E-mail: yuri.utin@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Fabritsiev, Sergey [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Giraud, Benoit; Guirao, Julio [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Koenig, Werner [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Kedrov, Igor; Kuzmin, Evgeny [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Levesy, Bruno; Martinez, Jean-Marc [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Prebeck, Markus [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Privalova, Elena [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Ranzinger, Franz [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Savrukhin, Petr [Russian Federation ITER Domestic Agency, Kurchatov sq.1, 123182 Moscow (Russian Federation); Schiller, Thomas [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); and others

    2015-10-15

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  7. Starting manufacturing phase of ITER upper ports

    International Nuclear Information System (INIS)

    Utin, Yuri; Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James; Fabritsiev, Sergey; Giraud, Benoit; Guirao, Julio; Koenig, Werner; Kedrov, Igor; Kuzmin, Evgeny; Levesy, Bruno; Martinez, Jean-Marc; Prebeck, Markus; Privalova, Elena; Ranzinger, Franz; Savrukhin, Petr; Schiller, Thomas

    2015-01-01

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  8. Development of the alternate entry port for the ATF

    International Nuclear Information System (INIS)

    Parsa, Z.

    1993-05-01

    We discussed a second entry port for the Accelerator Test Facility (ATF) injection system at Brookhaven National Laboratory, which consists of a photocathode rf gun and a straight - ahead beamline directly into the 50 MeV linac. The proposed second entry port should improve the beam quality and lower the emittance needed for FEL (Free Electron Laser), and laser - acceleration experiments. A discussion on the laser driven high brightness photoelectrons through the primary entry port (a low energy 180 degrees achromatic double bend transport line) now in operation, and a beam analysis for the proposed secondary port is also given

  9. Oak Ridge rf Test Facility

    International Nuclear Information System (INIS)

    Gardner, W.L.; Hoffman, D.J.; McCurdy, H.C.; McManamy, T.J.; Moeller, J.A.; Ryan, P.M.

    1985-01-01

    The rf Test Facility (RFTF) of Oak Ridge National Laboratory (ORNL) provides a national facility for the testing and evaluation of steady-state, high-power (approx.1.0-MW) ion cyclotron resonance heating (ICRH) systems and components. The facility consists of a vacuum vessel and two fully tested superconducting development magnets from the ELMO Bumpy Torus Proof-of-Principle (EBT-P) program. These are arranged as a simple mirror with a mirror ratio of 4.8. The axial centerline distance between magnet throat centers is 112 cm. The vacuum vessel cavity has a large port (74 by 163 cm) and a test volume adequate for testing prototypic launchers for Doublet III-D (DIII-D), Tore Supra, and the Tokamak Fusion Test Reactor (TFTR). Attached to the internal vessel walls are water-cooled panels for removing the injected rf power. The magnets are capable of generating a steady-state field of approx.3 T on axis in the magnet throats. Steady-state plasmas are generated in the facility by cyclotron resonance breakdown using a dedicated 200-kW, 28-GHz gyrotron. Available rf sources cover a frequency range of 2 to 200 MHz at 1.5 kW and 3 to 18 MHz at 200 kW, with several sources at intermediate parameters. Available in July 1986 will be a >1.0-MW, cw source spanning 40 to 80 MHz. 5 figs

  10. Heavy-Duty Vehicle Port Drayage Drive Cycle Characterization and Development: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Prohaska, Robert; Konan, Arnaud; Kelly, Kenneth; Lammert, Michael

    2016-08-01

    In an effort to better understand the operational requirements of port drayage vehicles and their potential for adoption of advanced technologies, National Renewable Energy Laboratory (NREL) researchers collected over 36,000 miles of in-use duty cycle data from 30 Class 8 drayage trucks operating at the Port of Long Beach and Port of Los Angeles in Southern California. These data include 1-Hz global positioning system location and SAE J1939 high-speed controller area network information. Researchers processed the data through NREL's Drive-Cycle Rapid Investigation, Visualization, and Evaluation tool to examine vehicle kinematic and dynamic patterns across the spectrum of operations. Using the k-medoids clustering method, a repeatable and quantitative process for multi-mode drive cycle segmentation, the analysis led to the creation of multiple drive cycles representing four distinct modes of operation that can be used independently or in combination. These drive cycles are statistically representative of real-world operation of port drayage vehicles. When combined with modeling and simulation tools, these representative test cycles allow advanced vehicle or systems developers to efficiently and accurately evaluate vehicle technology performance requirements to reduce cost and development time while ultimately leading to the commercialization of advanced technologies that meet the performance requirements of the port drayage vocation. The drive cycles, which are suitable for chassis dynamometer testing, were compared to several existing test cycles. This paper presents the clustering methodology, accompanying results of the port drayage duty cycle analysis and custom drive cycle creation.

  11. SRF cavity testing using a FPGA Self Excited Loop

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-08-30

    Various authors have previously studied the theory and practice of cavity testing, notably an extensive treatment by Powers [1] and Padamsee [2]. The advent of the digital Low Level RF (LLRF) electronics based on Field Programmable Logic Arrays (FPGA) provides various improvements over the rather complex systems used in the past as well as enabling new measurement techniques.In this document we reintroduce a technique that seems to have fallen out of practice in recent times, that is obtaining the coupling constant β through measurements from just one port, the reflected power port, of the directional coupler placed in front of the cavity.

  12. Testing of Prototype Magnetic Suspension Cryogenic Transfer Line

    Science.gov (United States)

    Fesmire, J. E.; Augustynowicz, S. D.; Nagy, Z. F.; Sojourner, S. J.; Shu, Q. S.; Cheng, G.; Susta, J. T.

    2006-04-01

    A 6-meter prototype cryogenic transfer line with magnetic suspension was tested for its mechanical and thermal performance at the Cryogenics Test Laboratory of NASA Kennedy Space Center (KSC). A test facility with two cryogenic end-boxes was designed and commissioned for the testing. Suspension mechanisms were verified through a series of tests with liquid nitrogen. The thermal performance of the prototype was determined using the new test apparatus. The tested prototype has incorporated temperature and vacuum pressure data acquisition ports, customized interfaces to cryogenic end-boxes, and instrumentation. All tests were conducted under simulated onsite transfer line working conditions. A static (boiloff rate measurement) testing method was employed to demonstrate the gross heat leak in the tested article. The real-time temperature distribution, vacuum level, levitation distance, and mass flow rate were measured. The main purpose of this paper is to summarize the testing facility design and preparation, test procedure, and primary test results. Special arrangements (such as turning on/off mechanical support units, observing levitation gap, and setting up the flowmeter) in testing of such a magnetically levitated transfer line are also discussed. Preliminary results show that the heat leak reduction of approximately one-third to one-half is achievable through such transfer lines with a magnetic suspension system.

  13. Testing Applications in MANET Environments through Emulation

    Directory of Open Access Journals (Sweden)

    Pietro Manzoni

    2009-01-01

    Full Text Available Mobile Ad Hoc Network solution testing is typically done using simulation. The simulated code is generally a simplified version of the real code, and thus code porting to actual operating systems lacks a strong validation. In this work we present Castadiva, a test-bed architecture that allows validating software solutions for real ad hoc network environments using low-cost, off-the-shelf devices and open source software. Castadiva is also compatible with the ns-2 simulator, allowing a combined and more complete evaluation. In this work we present our tool and the results obtained when evaluating videocalls in different scenarios, both static and dynamic.

  14. Automated testing and reverification for training simulators using SATAR

    International Nuclear Information System (INIS)

    Charles, R.D.; Gaddy, C.D.; Nargarkar, A.; Colley, R.

    1990-01-01

    This paper reports that simulators used to train nuclear power plant operators must be recertified periodically to ensure fidelity for training (10 CFR 55.45). The objective of the Simulator Automated Testing and Reverification (SATAR) project was to develop software to reverify dynamic simulator performance automatically. The software resides in a standard configuration personal computer and in the simulator computer; the two computers are linked via serial ports. SATAR will automatically run performance tests, collect and analyze data, and compare data with baseline performance data. With SATAR, support from operations and simulator support personnel can be reduced greatly, and the repeatability of performance tests can be improved

  15. Experimental determination of the drywell volume: 1/5 scale pressure suppression test

    International Nuclear Information System (INIS)

    Pitts, J.H.

    1977-01-01

    The BWR Mk 1 1/5 scale drywell volume, including space in all ports up to the first flange, was experimentally determined to be 10.01 m 3 with an uncertainty of +- 0.03 m 3 . The method of measurement used a 0.040879 m 3 calibrated volume that was initially filled with helium to 36.5 MPa. The calibrated volume was then connected to the drywell and the pressures equalized. The volumes of the vent pipes, instrumentation ports, and either the steam inlet or nitrogen inlet were subtracted from the measured drywell volume to obtain the net active drywell volume. The net active drywell volume is 9.87 m 3 for air tests and 9.85 m 3 for steam tests

  16. Testing Testing Testing.

    Science.gov (United States)

    Deville, Craig; O'Neill, Thomas; Wright, Benjamin D.; Woodcock, Richard W.; Munoz-Sandoval, Ana; Gershon, Richard C.; Bergstrom, Betty

    1998-01-01

    Articles in this special section consider (1) flow in test taking (Craig Deville); (2) testwiseness (Thomas O'Neill); (3) test length (Benjamin Wright); (4) cross-language test equating (Richard W. Woodcock and Ana Munoz-Sandoval); (5) computer-assisted testing and testwiseness (Richard Gershon and Betty Bergstrom); and (6) Web-enhanced testing…

  17. Potential use of battery packs from NCAP tested vehicles.

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, Joshua; Orendorff, Christopher J.

    2013-10-01

    Several large electric vehicle batteries available to the National Highway Traffic Safety Administration are candidates for use in future safety testing programs. The batteries, from vehicles subjected to NCAP crashworthiness testing, are considered potentially damaged due to the nature of testing their associated vehicles have been subjected to. Criteria for safe shipping to Sandia is discussed, as well as condition the batteries must be in to perform testing work. Also discussed are potential tests that could be performed under a variety of conditions. The ultimate value of potential testing performed on these cells will rest on the level of access available to the battery pack, i.e. external access only, access to the on board monitoring system/CAN port or internal electrical access to the battery. Greater access to the battery than external visual and temperature monitoring would likely require input from the battery manufacturer.

  18. 40 CFR 86.1337-96 - Engine dynamometer test run.

    Science.gov (United States)

    2010-07-01

    .... Plug the canister port that is normally connected to the fuel tank. (ii) Prepare the engine... test should be performed. (2) Connect evacuated sample collection bags to the dilute exhaust and... turned off, turn off the engine cooling fan(s) if used, and the CVS blower (or disconnect the exhaust...

  19. High Efficiency Non-isolated Three Port DC-DC Converter for PV-Battery Systems

    OpenAIRE

    Tomas Manez, Kevin; Anthon, Alexander; Zhang, Zhe; Ouyang, Ziwei; Franke, Toke

    2016-01-01

    This paper presents a nonisolated Three Port Converter (TPC) with a unidirectional port for photovoltaic (PV) panels and a bidirectional port for energy storage. With the proposed topology single power conversion is performed between each port, so high efficiencies are obtained. A theoretical analysis is carried out to analyze all operating modes and design considerations with the main equations are given. A 4kW laboratory prototype is developed and tested under all operatingconditions. Resul...

  20. 33 CFR 150.515 - What are the requirements for weight testing of newly installed or relocated craft?

    Science.gov (United States)

    2010-07-01

    ... weight testing of newly installed or relocated craft? 150.515 Section 150.515 Navigation and Navigable... testing of newly installed or relocated craft? (a) The operator must perform installation weight testing... (a) of this section, when survival crafts are relocated to another deepwater port. ...

  1. O&M report for DanWEC Hanstholm test site

    DEFF Research Database (Denmark)

    Grant, Christian Nereus; Tetu, Amélie

    The report is prepared for the Danish Energy Agency under The Energy Technology Development and Demonstration Program (EUDP), project “Resource Assessment, Forecasts and WECs O&M strategies at DanWEC and beyond”. This report includes observation, planning and maintenance descriptions for the Dan......WEC test site (HTS) located west of the Port of Hanstholm....

  2. An integrated port camera and display system for laparoscopy.

    Science.gov (United States)

    Terry, Benjamin S; Ruppert, Austin D; Steinhaus, Kristen R; Schoen, Jonathan A; Rentschler, Mark E

    2010-05-01

    In this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD). Brightness, contrast, hue, colorfulness, and sharpness were compared. The port camera video is superior to the Storz scope and approximately equivalent to the Stryker scope. An ex vivo study was conducted to measure the operative performance of the port camera. The results suggest that simulated tissue identification and biopsy acquisition with the port camera is as efficient as with a traditional laparoscopic system. The port camera was successfully used by a laparoscopic surgeon for exploratory surgery and liver biopsy during a porcine surgery, demonstrating initial surgical feasibility.

  3. Neutronics analysis for integration of ITER diagnostics port EP10

    Energy Technology Data Exchange (ETDEWEB)

    Colling, Bethany, E-mail: bethany.colling@ccfe.ac.uk [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Eade, Tim [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Joyce, Malcolm J. [Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Pampin, Raul; Seyvet, Fabien [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Turner, Andrew [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Udintsev, Victor [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Shutdown dose rate calculations have been performed on an integrated ITER C-lite neutronics model with equatorial port 10. A ‘fully shielded’ configuration, optimised for a given set of diagnostic designs (i.e. shielding in all available space within the port plug drawers), results in a shutdown dose rate in the port interspace, from the activation of materials comprising equatorial port 10, in excess of 2000 μSv/h. Achieving dose rates of 100 μSv/h or less, as required in areas where hands-on maintenance can be performed, in the port interspace region will be challenging. A combination of methods will need to be implemented, such as reducing mass and/or the use of reduced activation steel in the port interspace, optimisation of the diagnostic designs and shielding of the port interspace floor. Further analysis is required to test these options and the ongoing design optimisation of the EP10 diagnostic systems.

  4. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1998

    International Nuclear Information System (INIS)

    Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru; Kawasaki, Nobuo; Kume, Etsuo; Adachi, Masaaki; Ogasawara, Shinobu

    2000-03-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 12 codes in fiscal 1998. These results are reported in 3 parts, i.e., the vectorization and parallelization on vector processors part, the parallelization on scalar processors part and the porting part. In this report, we describe the porting. In this porting part, the porting of Monte Carlo N-Particle Transport code MCNP4B2 and Reactor Safety Analysis code RELAP5 on the AP3000 are described. In the vectorization and parallelization on vector processors part, the vectorization of General Tokamak Circuit Simulation Program code GTCSP, the vectorization and parallelization of Molecular Dynamics Ntv Simulation code MSP2, Eddy Current Analysis code EDDYCAL, Thermal Analysis Code for Test of Passive Cooling System by HENDEL T2 code THANPACST2 and MHD Equilibrium code SELENEJ on the VPP500 are described. In the parallelization on scalar processors part, the parallelization of Monte Carlo N-Particle Transport code MCNP4B2, Plasma Hydrodynamics code using Cubic Interpolated propagation Method PHCIP and Vectorized Monte Carlo code (continuous energy model/multi-group model) MVP/GMVP on the Paragon are described. (author)

  5. Design and tritium permeation analysis of China HCCB TBM port cell

    International Nuclear Information System (INIS)

    Jiangfeng, S.; Guoqiang, H.; Zhiyong, H.; Chang'an, C.; Deli, L.

    2015-01-01

    China is planning to develop a helium-cooled ceramic breeder (HCCB) test blanket module (TBM) on ITER to test key blanket technologies. In this paper, the design and tritium permeation analysis of China HCCB TBM port cell are introduced. A theoretical model has been developed to estimate tritium permeation rates and leak rates from the components and pipes which China has scheduled to house in the port cell. It is shown that on normal working conditions, the permeation and leak rate of the systems in the port cell will be no higher than 1.58 Ci/d without the use of tritium permeation barriers, and 0.10 Ci/d with the use of tritium permeation barriers. It also appears that tritium permeation barriers are necessary for high temperature components such as the reduction bed and the heater

  6. Design and tritium permeation analysis of China HCCB TBM port cell

    Energy Technology Data Exchange (ETDEWEB)

    Jiangfeng, S.; Guoqiang, H.; Zhiyong, H.; Chang' an, C.; Deli, L. [China Academy of Engineering Physics, Mianyang, Sichuan (China)

    2015-03-15

    China is planning to develop a helium-cooled ceramic breeder (HCCB) test blanket module (TBM) on ITER to test key blanket technologies. In this paper, the design and tritium permeation analysis of China HCCB TBM port cell are introduced. A theoretical model has been developed to estimate tritium permeation rates and leak rates from the components and pipes which China has scheduled to house in the port cell. It is shown that on normal working conditions, the permeation and leak rate of the systems in the port cell will be no higher than 1.58 Ci/d without the use of tritium permeation barriers, and 0.10 Ci/d with the use of tritium permeation barriers. It also appears that tritium permeation barriers are necessary for high temperature components such as the reduction bed and the heater.

  7. Space Shuttle Boundary Layer Transition Flight Experiment Ground Testing Overview

    Science.gov (United States)

    Berger, Karen T.; Anderson, Brian P.; Campbell, Charles H.

    2014-01-01

    In support of the Boundary Layer Transition (BLT) Flight Experiment (FE) Project in which a manufactured protuberance tile was installed on the port wing of Space Shuttle Orbiter Discovery for STS-119, STS- 128, STS-131 and STS-133 as well as Space Shuttle Orbiter Endeavour for STS-134, a significant ground test campaign was completed. The primary goals of the test campaign were to provide ground test data to support the planning and safety certification efforts required to fly the flight experiment as well as validation for the collected flight data. These test included Arcjet testing of the tile protuberance, aerothermal testing to determine the boundary layer transition behavior and resultant surface heating and planar laser induced fluorescence (PLIF) testing in order to gain a better understanding of the flow field characteristics associated with the flight experiment. This paper provides an overview of the BLT FE Project ground testing. High-level overviews of the facilities, models, test techniques and data are presented, along with a summary of the insights gained from each test.

  8. Field evaluation of a horizontal well recirculation system for groundwater treatment: Pilot test at the Clean Test Site Portsmouth Gaseous Diffusion Plant, Piketon, Ohio

    International Nuclear Information System (INIS)

    Muck, M.T.; Kearl, P.M.; Siegrist, R.L.

    1998-01-01

    This report presents the results of field testing a horizontal well recirculation system at the Portsmouth Gaseous Diffusion Plant (PORTS). The recirculation system uses a pair of horizontal wells, one for groundwater extraction and treatment and the other for reinjection of treated groundwater, to set up a recirculation flow field. The induced flow field from the injection well to the extraction well establishes a sweeping action for the removal and treatment of groundwater contaminants. The overall purpose of this project is to study treatment of mixed groundwater contaminants that occur in a thin water-bearing zone not easily targeted by traditional vertical wells. The project involves several research elements, including treatment-process evaluation, hydrodynamic flow and transport modeling, pilot testing at an uncontaminated site, and pilot testing at a contaminated site. The results of the pilot test at an uncontaminated site, the Clean Test Site (CTS), are presented in this report

  9. Sudden venting test of an emergency bearing for the magnet bearing type compound molecular pump

    International Nuclear Information System (INIS)

    Hiroki, Seiji; Abe, Tetsuya; Murakami, Yoshio; Okamoto, Masatomo; Iguchi, Masashi; Nakamura, Jyunichi; Nakazeki, Tsugito.

    1995-01-01

    The vacuum evacuation system for nuclear fusion reactors bears the role of exhausting hydrogen isotopes in large quantity together with helium continuously for long hours, and as the high vacuum pumps for this purpose, the mechanical pumps which can do continuous evacuation and decrease the quantity of staying radioactive tritium, such as turbo molecular pumps and compound molecular pumps, are promising. Because of the compatibility with tritium, oil lubrication is not desirable, accordingly, the pumps with ceramic rotating vanes and magnetic bearings are demanded. As a part of the development of a magnetic bearing type mechanical pump which can be used for nuclear fusion reactors, the compound molecular pump, in which emergency bearings were incorporated, was made for trial, and the test of sudden air intrusion was carried out, as the results, various knowledges were obtained. The constitution of the testing setup, and the test results are reported. When air was injected at the pressure rise of 3.3x10 4 Pa/s from exhaust port side, after about 2.5 s, the maximum lift of 4.2x10 3 N arose. When air was injected at the pressure rise of 2.7x10 5 Pa/s from the suction part side, after about 0.4s, the maximum lift of 6.9x10 3 N arose. In the air injection alternately from the suction port and exhaust port sides, the emergency bearings functioned normally in 10 times of the test. (K.I.)

  10. Investigating performance of microchannel evaporators for automobile air conditioning with different port structures

    Directory of Open Access Journals (Sweden)

    Guoliang Zhou

    2017-08-01

    Full Text Available Microchannel evaporator has been widely applied in automobile air conditioning, while it faces the problem of refrigerant maldistribution which deteriorates the thermal performance of evaporator. In this study, the performances of microchannel evaporators with different port structures are experimentally investigated for purpose of reducing evaporator pressure drop. Four evaporator samples with different port number and hydraulic diameter are made for this study. The performances of the evaporator samples are tested on a psychometric calorimeter test bench with the refrigerant R-134A at a real automobile air conditioning. The results on the variations of the evaporator pressure drop and evaporator surface temperature distribution are presented and analyzed. By studying the performance of an evaporator, seeking proper port structure is an approach to reduce refrigerant pressure drop as well as improve refrigerant distribution.

  11. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    Directory of Open Access Journals (Sweden)

    E. Adli

    2011-08-01

    Full Text Available We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter regime of CLIC.

  12. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    CERN Document Server

    Adli, E; Dubrovskiy, A; Syratchev, I; Ruber, R; Ziemann, V

    2011-01-01

    We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter reg...

  13. Using Spare Logic Resources To Create Dynamic Test Points

    Science.gov (United States)

    Katz, Richard; Kleyner, Igor

    2011-01-01

    A technique has been devised to enable creation of a dynamic set of test points in an embedded digital electronic system. As a result, electronics contained in an application specific circuit [e.g., gate array, field programmable gate array (FPGA)] can be internally probed, even when contained in a closed housing during all phases of test. In the present technique, the test points are not fixed and limited to a small number; the number of test points can vastly exceed the number of buffers or pins, resulting in a compact footprint. Test points are selected by means of spare logic resources within the ASIC(s) and/or FPGA(s). A register is programmed with a command, which is used to select the signals that are sent off-chip and out of the housing for monitoring by test engineers and external test equipment. The register can be commanded by any suitable means: for example, it could be commanded through a command port that would normally be used in the operation of the system. In the original application of the technique, commanding of the register is performed via a MIL-STD-1553B communication subsystem.

  14. Operation of a nuclear test gage at low multiplications

    International Nuclear Information System (INIS)

    Baumann, N.P.

    1977-01-01

    The Nuclear Test Gage (NTG) at the Savannah River Plant is a subcritical multiplying facility (low k) with H 2 O moderator and 2.54-cm-diameter fuel slugs of 5 wt percent 235 U in aluminum alloy at a 4.285-cm triangular pitch. The core of the facility is 61-cm long with a normal diameter of 27 cm. The NTG is used for quality control of reactor components, such as 235 U-Al fuel tubes, Li--Al target tubes, control and safety rods, and miscellaneous special irradiation elements. A component is tested by passing it through an axial test port 11.63 cm in diameter. The ion chamber response from the resultant change in neutron source multiplication is then compared with corresponding responses from known standards

  15. The Method of System Test using I/O Stimulator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Yeol; Lee, Dong Young; Kim, Chang Hoi [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In general, the software development life cycle consists of the requirement phase, design phase, implementation phase, testing phase, integration phase (software-software integration, software-hardware integration), installation phase, and operation and maintenance phase. The fundamental parts to the testing phase are component test, software integration test, software hardware integration test, and system test. Among these tests, we focused in particular on system test using I/O stimulator. The system test operates the functionality, performance, and interface because system testing falls within the scope of black box testing, which should not require knowledge of the inner design of the code or logic. The purpose of developing a system test using a I/O stimulator is to save time and effort from the functionality and performance tests. We developed an I/O stimulator for the burning system test based on the operational scenario. The hardware, software, and manmachine- interface (MMI) are fundamental parts to the I/O stimulator. Signal sources from the I/O stimulator contain analog input, analog output, digital input, digital output, a Programmable Power Supply, an RS232C Serial interface and a dual port Ethernet interface. While automation cannot reproduce everything that a software engineer can do, it can be extremely useful for the system test. However, it does require the test criteria and a well-developed test suite of the testing scripts in order to be useful. In this study, we developed a multipurpose and cost-efficient I/O stimulator using LabVIEW program instead of the testing scripts.

  16. The Method of System Test using I/O Stimulator

    International Nuclear Information System (INIS)

    Kim, Jang Yeol; Lee, Dong Young; Kim, Chang Hoi

    2016-01-01

    In general, the software development life cycle consists of the requirement phase, design phase, implementation phase, testing phase, integration phase (software-software integration, software-hardware integration), installation phase, and operation and maintenance phase. The fundamental parts to the testing phase are component test, software integration test, software hardware integration test, and system test. Among these tests, we focused in particular on system test using I/O stimulator. The system test operates the functionality, performance, and interface because system testing falls within the scope of black box testing, which should not require knowledge of the inner design of the code or logic. The purpose of developing a system test using a I/O stimulator is to save time and effort from the functionality and performance tests. We developed an I/O stimulator for the burning system test based on the operational scenario. The hardware, software, and manmachine- interface (MMI) are fundamental parts to the I/O stimulator. Signal sources from the I/O stimulator contain analog input, analog output, digital input, digital output, a Programmable Power Supply, an RS232C Serial interface and a dual port Ethernet interface. While automation cannot reproduce everything that a software engineer can do, it can be extremely useful for the system test. However, it does require the test criteria and a well-developed test suite of the testing scripts in order to be useful. In this study, we developed a multipurpose and cost-efficient I/O stimulator using LabVIEW program instead of the testing scripts

  17. Interpretation of the tracer testing conducted in the Leuggern borehole

    International Nuclear Information System (INIS)

    McNeish, J.A.; Andrews, R.W.; Vomvoris, S.

    1990-12-01

    Tracer testing was conducted in the Leuggern borehole from July to December 1988 to evaluate the hydraulic properties of the crystalline host rock. The tested interval was an approximately 50 m section of fractured crystalline rock at a depth of greater than 1,600 m. The testing consisted of three tracer injection/recovery periods (uranin - 44 days, eosin - 30 days, and naphtionat -14 days), which utilized tracer injection/circulation rates, ranging between 25 and 50 ml/min. During these testing periods, tracer was injected in either of two 1/4 flow lines ported at the top or bottom of the interval and recovered from the other. Following the three tracer injection periods, a natural outflow tracer recovery test was conducted from the central tubing at an average outflow of 12 l/min. The central tubing was ported near the center of the test interval. Data collected during the testing periods included: continuous monitoring of fluid temperature, injection pressure, and electrical conductivity as well as discrete measurement of flow rates, electrical conductivity, fluid temperature, and tracer concentration. Testing results indicate a downward vertical flow of approximately 195-225 ml/min in the isolated interval, from an upper fracture inflow zone to a lower fracture outflow zone. Through analysis of the dilution levels of uranin and eosin during the injection/recovery periods, and review of field data, the top of the upper inflow zone was determined to be approximately 13 m below the top flow line and the bottom of the outflow zone to be approximately 3 to 5 meters above the bottom flow line. The calculated transmissivity value of 6E-05 m 2 /s from observed outflow rate and pressure recovery data, is consistent with results derived from previous hydraulic packer testing in the interval. The effective porosity was determined to be 0.1. Dispersion coefficient values ranged from 1.0 m to 5.0 m. The lateral hydraulic gradient value calculated from tracer recovery

  18. Design and construction of multi-port solid state structure for the Rhodotron accelerator

    International Nuclear Information System (INIS)

    Poursaleh, A.M.; Jabbari, I.; Khalafi, H.

    2017-01-01

    RF generation and method used for coupling power to the acceleration cavity are important issues in the RF accelerators. In this study, a high power vacuum tube was replaced with several medium power solid state amplifiers coupled through a multi-port structure in the Rhodotron-TT200 accelerator. To this end, a multi-port structure was implemented on a small aluminum model cavity for 1 to 9 ports and all main parameters affecting return loss, quality factor, coupling coefficient and RF power were investigated by calculation, simulation and experimental tests. Then, three 20 kW solid state amplifiers were designed and constructed. The outputs of these amplifiers were coupled to the Rhodotron acceleration cavity by three input ports based on the results obtained from the model cavity for generation of 5 MeV electron beam. In this method, several smaller amplifiers were used instead of a single high power amplifier. As such, acceleration cavity plays the role of power combiner in addition to its primary role and there is no need to a high power combiner. The results showed that the number of ports, port positions, angle between ports and phase of input signals, significantly affect the acceleration electrical field in the cavity. Also, experimental tests revealed that three constructed RF power supplies are enough for the generation of 5 MeV electron beam in the Rhodotron accelerator. Considering the advantages of the solid state amplifiers, application of multi-port structure and solid state amplifiers could be expanded in the industrial electron accelerators.

  19. Vaccination-challenge studies with a Port Chalmers/73 (H3N2)-based swine influenza virus vaccine: Reflections on vaccine strain updates and on the vaccine potency test.

    Science.gov (United States)

    De Vleeschauwer, Annebel; Qiu, Yu; Van Reeth, Kristien

    2015-05-11

    The human A/Port Chalmers/1/73 (H3N2) influenza virus strain, the supposed ancestor of European H3N2 swine influenza viruses (SIVs), was used in most commercial SIV vaccines in Europe until recently. If manufacturers want to update vaccine strains, they have to perform laborious intratracheal (IT) challenge experiments and demonstrate reduced virus titres in the lungs of vaccinated pigs. We aimed to examine (a) the ability of a Port Chalmers/73-based commercial vaccine to induce cross-protection against a contemporary European H3N2 SIV and serologic cross-reaction against H3N2 SIVs from Europe and North America and (b) the validity of intranasal (IN) challenge and virus titrations of nasal swabs as alternatives for IT challenge and titrations of lung tissue in vaccine potency tests. Pigs were vaccinated with Suvaxyn Flu(®) and challenged by the IT or IN route with sw/Gent/172/08. Post-vaccination sera were examined in haemagglutination-inhibition assays against vaccine and challenge strains and additional H3N2 SIVs from Europe and North America, including an H3N2 variant virus. Tissues of the respiratory tract and nasal swabs were collected 3 days post challenge (DPCh) and from 0-7 DPCh, respectively, and examined by virus titration. Two vaccinations consistently induced cross-reactive antibodies against European H3N2 SIVs from 1998-2012, but minimal or undetectable antibody titres against North American viruses. Challenge virus titres in the lungs, trachea and nasal mucosa of the vaccinated pigs were significantly reduced after both IT and IN challenge. Yet the reduction of virus titres and nasal shedding was greater after IT challenge. The Port Chalmers/73-based vaccine still offered protection against a European H3N2 SIV isolated 35 years later and with only 86.9% amino acid homology in its HA1, but it is unlikely to protect against H3N2 SIVs that are endemic in North America. We use our data to reflect on vaccine strain updates and on the vaccine potency test

  20. Automating Test Activities: Test Cases Creation, Test Execution, and Test Reporting with Multiple Test Automation Tools

    OpenAIRE

    Loke Mun Sei

    2015-01-01

    Software testing has become a mandatory process in assuring the software product quality. Hence, test management is needed in order to manage the test activities conducted in the software test life cycle. This paper discusses on the challenges faced in the software test life cycle, and how the test processes and test activities, mainly on test cases creation, test execution, and test reporting is being managed and automated using several test automation tools, i.e. Jira, ...

  1. Wrapper design for the reuse of a bus, network-on-chip, or other functional interconnect as test access mechanism

    NARCIS (Netherlands)

    Amory, A.M.; Goossens, K.G.W.; Marinissen, Erik Jan; Lubaszewski, M.; Moraes, F.

    2007-01-01

    A new core test wrapper design approach is proposed which transports streaming test data, for example scan test patterns, into and out of an embedded core exclusively via (some of) its functional data ports. The latter are typically based on standardised protocols such as AXI, DTL, and OCP. The new

  2. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  3. Monitoring ecotoxicological and Environmental Testing Using with Biosurfactants Evaluation of Zone Water Quality Port | Monitoramento de testes ecotoxicológicos e ambientais Usando com biossurfactantes avaliação do porto de qualidade da água da zona

    Directory of Open Access Journals (Sweden)

    Itala Gabriela Sobral dos Santos

    2016-10-01

    Full Text Available Biosurfactants can be used in environmental pollution control systems for oil spill and its derivatives, since they increase the bioavailability of contaminants by reducing the surface tension of water. The mollusk Anomalocardia brasiliana is a species that inhabits areas with little suspended material. The aim was to test the tolerance concentration and the median lethal concentration (LC50 for a period of 96h through survival. The experiment was conducted at UFRPE, and the biosurfactant produced the root Candida lipolytica, having an industrial waste as a source of carbon, plus mineral medium. The animals were not fed for 24 hr prior to the experiment. It was performed six treatments (1:10, 1:20, 1:40, 1:80 and 1: 160 in three replicates, with the density of 2.5 individual / Litre and subjected to constant aeration at a temperature of 26 ± 0 5 ° C and salinity 26. It follows that the treatments 1 (1:10 and 2 (1:20 gave a survival 76.18%, however treatments 3 (95.23% and 4 (95 83% were higher and treating with 5 to 100%. The LC50 estimated for the biosurfactant tested was 0.222 or 1: 4.5. The compound is lethal to the test organism used in dilutions being suggested further experiments with dilutions from 1: 05 to 1:20, to better estimate of LC50 for the same species. Thus, a better understanding of the lethal concentration in organisms representing different trophic levels brings positive results to optimize the procedures in environmental monitoring in port areas.

  4. Modifying the test of understanding graphs in kinematics

    Science.gov (United States)

    Zavala, Genaro; Tejeda, Santa; Barniol, Pablo; Beichner, Robert J.

    2017-12-01

    In this article, we present several modifications to the Test of Understanding Graphs in Kinematics. The most significant changes are (i) the addition and removal of items to achieve parallelism in the objectives (dimensions) of the test, thus allowing comparisons of students' performance that were not possible with the original version, and (ii) changes to the distractors of some of the original items that represent the most frequent alternative conceptions. The final modified version (after an iterative process involving four administrations of test variations over two years) was administered to 471 students of an introductory university physics course at a large private university in Mexico. When analyzing the final modified version of the test it was found that the added items satisfied the statistical tests of difficulty, discriminatory power, and reliability; also, that the great majority of the modified distractors were effective in terms of their frequency selection and discriminatory power; and, that the final modified version of the test satisfied the reliability and discriminatory power criteria as well as the original test. Here, we also show the use of the new version of the test, presenting a new analysis of students' understanding not possible to do before with the original version of the test, specifically regarding the objectives and items that in the new version meet parallelisms. Finally, in the PhysPort project (physport.org), we present the final modified version of the test. It can be used by teachers and researchers to assess students' understanding of graphs in kinematics, as well as their learning about them.

  5. WRAP low level waste restricted waste management (LLW RWM) glovebox acceptance test report

    International Nuclear Information System (INIS)

    Leist, K.J.

    1997-01-01

    On April 22, 1997, the Low Level Waste Restricted Waste Management (LLW RWM) glovebox was tested using acceptance test procedure 13027A-87. Mr. Robert L. Warmenhoven served as test director, Mr. Kendrick Leist acted as test operator and test witness, and Michael Lane provided miscellaneous software support. The primary focus of the glovebox acceptance test was to examine glovebox control system interlocks, operator Interface Unit (OIU) menus, alarms, and messages. Basic drum port and lift table control sequences were demonstrated. OIU menus, messages, and alarm sequences were examined, with few exceptions noted. Barcode testing was bypassed, due to the lack of installed equipment as well as the switch from basic reliance on fixed bar code readers to the enhanced use of portable bar code readers. Bar code testing was completed during performance of the LLW RWM OTP. Mechanical and control deficiencies were documented as Test Exceptions during performance of this Acceptance Test. These items are attached as Appendix A to this report

  6. Three ports versus four ports laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Shah, S.F.; Waqar, S.; Chaudry, M.A.; Hameed, S.

    2017-01-01

    To compare three ports laparoscopic cholecystectomy and four ports laparoscopic cholecystectomy in terms of complications, time taken to complete the procedure, hospital stay and cost effectiveness in local perspective. Methodology: This randomized control trial included 60 patients who underwent elective laparoscopic cholecystectomy at Department of Surgery, Pakistan Institute of Medical Sciences, Islamabad, Pakistan from January 2013 to June 2013. These patients were randomized on computer generated table of random numbers into group A and Group B. In Group A patients four ports were passed to perform laparoscopic cholecystectomy and in Group B patients three ports were passed to perform the procedure. Results: The mean age in both groups was 44 years (range 18-72). Three ports laparoscopic cholecystectomy (43 min) took less time to complete than four ports laparoscopic cholecystectomy (51 min). Patients in three ports laparoscopic cholecystectomy experienced less pain as compared to four ports group. The total additional analgesia requirement in 24 hours calculated in milligrams was less in three port laparoscopic cholecystectomy group as compared four port laparoscopic cholecystectomy group. The mean hospital stay in three port laparoscopic cholecystectomy group is 25 hours while the mean hospital stay in the four port laparoscopic cholecystectomy group is 28 hours. Conclusion: Three ports laparoscopic cholecystectomy is safe and effective procedure and it did not compromise the patient safety. (author)

  7. A Modeling Tool for Household Biogas Burner Flame Port Design

    Science.gov (United States)

    Decker, Thomas J.

    Anaerobic digestion is a well-known and potentially beneficial process for rural communities in emerging markets, providing the opportunity to generate usable gaseous fuel from agricultural waste. With recent developments in low-cost digestion technology, communities across the world are gaining affordable access to the benefits of anaerobic digestion derived biogas. For example, biogas can displace conventional cooking fuels such as biomass (wood, charcoal, dung) and Liquefied Petroleum Gas (LPG), effectively reducing harmful emissions and fuel cost respectively. To support the ongoing scaling effort of biogas in rural communities, this study has developed and tested a design tool aimed at optimizing flame port geometry for household biogas-fired burners. The tool consists of a multi-component simulation that incorporates three-dimensional CAD designs with simulated chemical kinetics and computational fluid dynamics. An array of circular and rectangular port designs was developed for a widely available biogas stove (called the Lotus) as part of this study. These port designs were created through guidance from previous studies found in the literature. The three highest performing designs identified by the tool were manufactured and tested experimentally to validate tool output and to compare against the original port geometry. The experimental results aligned with the tool's prediction for the three chosen designs. Each design demonstrated improved thermal efficiency relative to the original, with one configuration of circular ports exhibiting superior performance. The results of the study indicated that designing for a targeted range of port hydraulic diameter, velocity and mixture density in the tool is a relevant way to improve the thermal efficiency of a biogas burner. Conversely, the emissions predictions made by the tool were found to be unreliable and incongruent with laboratory experiments.

  8. SYSTEMS FOR IMPROVEMENT OF BUSINESS INTEGRATED MANAGEMENT PROCESSES IN PORTS

    Directory of Open Access Journals (Sweden)

    Pavle Popovic

    2017-03-01

    Full Text Available Based on test results obtained so far, the objective relating to modern scientific methods and approaches has been defined with the intention to develop model which defines new management system integration model, by adopting necessary practical terms of real systems that most frequently circulate in maritime practice in the field of integrated management systems (IMS in terms of safety and security of vessels and ports. The subject of research is maritime, particularly port services, by way of defining internal and external advantages through adopting integrated management systems. The research will be conducted through theoretical and applied assessments of case study analyses using example of the Port of Kotor H.Co.

  9. Incidence and risk factors of infections complications related to implantable venous-access ports

    International Nuclear Information System (INIS)

    Shim, Ji Sue; Seo, Tae Seok; Song, Myung Gyu; Cha, In Ho; Kim, Jun Suk; Choi, Chul Won; Seo, Jae Hong; Oh, Sang Cheul

    2014-01-01

    The purpose of this study was to determine the incidence and risk factors of infections associated with implantable venous access ports (IVAPs.) From August 2003 through November 2011, 1747 IVAPs were placed in our interventional radiology suite. One hundred forty four IVAPs were inserted in patients with hematologic malignancy and 1603 IVAPs in patients with solid tumors. Among them, 40 ports (23 women and 17 men; mean age, 57.1 years; range, 13-83) were removed to treat port-related infections. We evaluated the incidence of port-related infection, patient characteristics, bacteriologic data, and patient progress. Univariable analyses (t test, chi-square test, and Fisher's exact test) and multiple logistic regression analyses were used to determine the risk factors for IVAP related infection. Overall, 40 (2.3%) of 1747 ports were removed for symptoms of infection with an incidence rate of 0.067 events/1000 catheter-days. According to the univariable study, the incidences of infection were seemingly higher in the patients who received the procedure during inpatient treatment (p = 0.016), the patients with hematologic malignancy (p = 0.041), and the patients receiving palliative chemotherapy (p = 0.022). From the multiple binary logistic regression, the adjusted odds ratios of infection in patients with hematologic malignancies and those receiving palliative chemotherapy were 7.769 (p = 0.001) and 4.863 (p = 0.003), respectively. Microorganisms were isolated from 26 (65%) blood samples, and two of the most causative organisms were found to be Staphylococcus (n = 10) and Candida species (n = 7). The underlying hematologic malignancy and the state of receiving palliative chemotherapy were the independent risk factors of IVAP-related infection.

  10. Incidence and risk factors of infections complications related to implantable venous-access ports

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Ji Sue; Seo, Tae Seok; Song, Myung Gyu; Cha, In Ho; Kim, Jun Suk; Choi, Chul Won; Seo, Jae Hong; Oh, Sang Cheul [Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2014-08-15

    The purpose of this study was to determine the incidence and risk factors of infections associated with implantable venous access ports (IVAPs.) From August 2003 through November 2011, 1747 IVAPs were placed in our interventional radiology suite. One hundred forty four IVAPs were inserted in patients with hematologic malignancy and 1603 IVAPs in patients with solid tumors. Among them, 40 ports (23 women and 17 men; mean age, 57.1 years; range, 13-83) were removed to treat port-related infections. We evaluated the incidence of port-related infection, patient characteristics, bacteriologic data, and patient progress. Univariable analyses (t test, chi-square test, and Fisher's exact test) and multiple logistic regression analyses were used to determine the risk factors for IVAP related infection. Overall, 40 (2.3%) of 1747 ports were removed for symptoms of infection with an incidence rate of 0.067 events/1000 catheter-days. According to the univariable study, the incidences of infection were seemingly higher in the patients who received the procedure during inpatient treatment (p = 0.016), the patients with hematologic malignancy (p = 0.041), and the patients receiving palliative chemotherapy (p = 0.022). From the multiple binary logistic regression, the adjusted odds ratios of infection in patients with hematologic malignancies and those receiving palliative chemotherapy were 7.769 (p = 0.001) and 4.863 (p = 0.003), respectively. Microorganisms were isolated from 26 (65%) blood samples, and two of the most causative organisms were found to be Staphylococcus (n = 10) and Candida species (n = 7). The underlying hematologic malignancy and the state of receiving palliative chemotherapy were the independent risk factors of IVAP-related infection.

  11. Hypertension detection and control in Port Harcourt: knowledge gap ...

    African Journals Online (AJOL)

    ... on continuing medical education on hypertension in Port Harcourt, Nigeria was conducted in June 2013. Post test was also administered. Participants were drawn from both private and public medical practice. The questionnaire contained demographic data and knowledge of diagnosis and treatment of hypertension.

  12. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (porting). Progress report fiscal 1997

    International Nuclear Information System (INIS)

    Ishizuki, Shigeru; Nemoto, Toshiyuki; Kawai, Wataru; Watanabe, Hideo; Tanabe, Hidenobu; Kawasaki, Nobuo; Adachi, Masaaki; Ogasawara, Shinobu; Kume, Etsuo

    1999-05-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system and/or the AP3000 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 14 codes in fiscal 1997. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the porting. In this porting part, the porting of transient reactor analysis code TRAC-BF1 and Monte Carlo radiation transport code MCNP4A on the AP3000 are described. In addition, a modification of program libraries for command-driven interactive data analysis plotting program IPLOT is described. In the vectorization part, the vectorization of multidimensional two-fluid model code ACE-3D for evaluation of constitutive equations, statistical decay code SD and three-dimensional thermal analysis code for in-core test section (T2) of HENDEL SSPHEAT are described. In the parallelization part, the parallelization of cylindrical direct numerical simulation code CYLDNS44N, worldwide version of system for prediction of environmental emergency dose information code WSPEEDI, extension of quantum molecular dynamics code EQMD and three-dimensional non-steady compressible fluid dynamics code STREAM are described. (author)

  13. Live Operation Data Collection Optimization and Communication for the Domestic Nuclear Detection Office's Rail Test Center

    International Nuclear Information System (INIS)

    Gelston, Gariann M.

    2010-01-01

    For the Domestic Nuclear Detection Office's Rail Test Center (i.e., DNDO's RTC), port operation knowledge with flexible collection tools and technique are essential in both technology testing design and implementation intended for live operational settings. Increased contextual data, flexibility in procedures, and rapid availability of information are keys to addressing the challenges of optimization, validation, and analysis within live operational setting data collection. These concepts need to be integrated into technology testing designs, data collection, validation, and analysis processes. A modified data collection technique with a two phased live operation test method is proposed.

  14. He leak testing of Indus-2 dipole vacuum chambers

    International Nuclear Information System (INIS)

    Sindal, B.K.; Bhavsar, S.T.; Shukla, S.K.

    2003-01-01

    Full text: Centre for Advanced Technology is developing its second synchrotron radiation source INDUS-2 which is a 2.5 GeV electron storage ring. Dipole vacuum chambers are the vital components of Indus-2 vacuum system. Each of these chambers is approx. 3.6 m long and 0.67 m wide with 24 nos. of ports of various sizes. The dipole chambers were made by machining two halves and they are then lip welded together. The dipole chamber has approx. 14 m of total weld length and it was leak tested for leak tightness of the order of 10 -10 mbar 1/s. Helium mass spectrometer leak detector (HMSLD) was utilized for the leak testing. Subsequently the leaks of various orders in welding joints were repaired and leak tightness achieved. This paper describes the experiences during leak testing of 20 nos. of aluminum dipole chambers for INDUS-2

  15. Fabrication and Testing of Pyramidal X- Band Standard Horn Antenna

    Directory of Open Access Journals (Sweden)

    Hasan F. Khazaal

    2017-11-01

    Full Text Available Standard horn antennas are an important device to evaluate many types of antennas, since they are used as a reference to any type of antennas within the microwave frequency bands. In this project the fabrication process and tests of standard horn antenna operating at X-band frequencies have been proposed. The fabricated antenna passed through multi stages of processing of its parts until assembling the final product. These stages are (milling, bending, fitting and welding. The assembled antenna subjected to two types of tests to evaluate its performance. The first one is the test by two port network analyzer to point out S & Z parameters, input resistance, and the voltage standing wave ratio of the horn, while the second test was done using un-echoic chamber to measure the gain, side lobes level and the half power beam width. The results of testing come nearly as a theoretical value of the most important of antenna parameters, like; gain, side lobe level, -3 dB beam width, return loss and voltage standing wave ratio "VSWR", input Impedance.

  16. INTERFACE DEVICE FOR NONDESTRUCTIVE TESTING OF RESIDUAL SURFACE STRESSES

    Directory of Open Access Journals (Sweden)

    Gennady A. Perepelkin

    2016-01-01

    Full Text Available The paper considers the organization of connection of a personal computer with a device for nondestructive testing of residual surface stresses. The device works is based on the phenomenon of diffraction of ionizing radiation from the crystal lattice near the surface of the crystallites. Proposed software interface to the organization for each type of user: the device developers, administrators, users. Some aspects of the organization of communication microcontroller to a PC via USB-port

  17. Ports Primer: 3.2 Port Governance

    Science.gov (United States)

    State and local governments are important players in port governance and in oversight of transportation projects that may affect ports. Private corporations may also play a role if they lease or own a terminal at a port.

  18. Development and test of decoupler for ICRF antenna in EAST

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gen, E-mail: chengen@ipp.ac.cn; Mao, Yuzhou; Zhao, Yanping; Yuan, Shuai; Zhang, Xinjun; Qing, Chengming

    2016-06-15

    Highlights: • The mechanism of decoupler for ICRF antenna is proposed. • Three candidate assembly positions for the decouper can be used. • The performance relies on the ohmic dissipation and the assembly position of decoupler. - Abstract: Ion Cyclotron Range of Frequency (ICRF) heating has been adopted in EAST tokamak as one of main auxiliary heating methods. The ICRF antenna usually consists of multiple launching elements because of limited port and space of tokamak device. Mutual coupling between straps has been observed in previous EAST ICRF current drive experiments. Due to adverse effects of such mutual coupling, many issues induced by cross power cannot be ignored, such as power imbalance in feed lines, high voltage standing wave ratio (VSWR), and etc. To restrain such mutual coupling, A device named decoupler was developed and tested in EAST ICRF system. According to the admittance matrix of load, three assembly positions (oscillation position, optimum position, and smooth position) along transmission line for the decoupler were taken into account and tested. The test results showed that ohmic dissipation in decoupler could not be neglected, which partly influenced the decoupling performance. The oscillation position and optimum position could restrain such adverse effects of ohmic dissipation and showed good decoupling performance. However, they cannot ensure the steady operation during H-mod due to the load variation. Finally, the smooth position has been adopted for EAST I port antenna because of steady decoupling performance comprised with engineering error and load resilience, which sincerely enhance the capability of system operation.

  19. Cooperation Performance Evaluation between Seaport and Dry Port; Case of Qingdao Port and Xi'an Port

    Directory of Open Access Journals (Sweden)

    Jian Li

    2014-12-01

    Full Text Available Along with the drastic competition among ports, the strive for the vast economic hinterland and the supply of goods have become strategic problems for port operators. At the same time, port enterprises are paying more and more attention to the construction of dry ports. This article establishes the port cooperation performance evaluation index based on the balanced score card method and uses the grey relational degree method to evaluate the cooperation performance between seaports and dry ports. Finally using Qingdao port and Xi'an port as an example, and Zhengzhou port and Lanzhou port as benchmarks, the application of this evaluation method is introduced in detail. The conclusion reveals that cooperation between Qingdao port and Xi'an port has deficiencies in customer satisfaction, financial cooperation and non-market tools. Alongside this, the author proposes related issues about information management in the supply chain, competition position and the scope of hinterland. This article, combined with the related theory of supply chain and performance evaluation, puts forward a set of relatively complete cooperation performance evaluations between seaports and dry ports, which provide scientific theory support for better cooperation.

  20. TEST BEAM COORDINATION: Major upgrade of the ATLAS Test Beam network infrastructure

    CERN Multimedia

    Di Girolamo, B; Pasqualucci, E

    Based on the positive experience gained last year by the Muon group with the adoption of a completely isolated private network for the data acquisition, already last year for the 2002 Combined Pixel-Tilecal-Muon Test Beam, we adopted the private network solution. The main advantage of the isolation from the common CERN network infrastructure is the complete independence from possible problems that could affect the network in the area, intended to serve many other users, and the possibility to have a completely independent management of the IP addresses assignment. Moreover the presence of a firewall in the private network allows a better protection against possible external hackers, allowing users to transparently access the external word. A Fast Ethernet network has been set up as a control network. It relies on a backbone 24-port Fast Ethernet switch on which, in a tree structure, are connected several smaller switches dedicated to each sub-detector. In this way each sub-detector produces its own traffic...

  1. 40 CFR Table 3 to Subpart Lllll of... - Requirements for Performance Tests a,b

    Science.gov (United States)

    2010-07-01

    ... port's location and the number of traverse points i. EPA test method 1 or 1A in appendix A to part 60..., THC destruction efficiency, THC outlet concentration, or combustion efficiency standards, the sampling... combustion efficiency or THC standards a. Measure the concentration of carbon dioxideb. Measure the...

  2. Brayton-Cycle Power-Conversion Unit Tested With Ion Thruster

    Science.gov (United States)

    Hervol, David S.

    2005-01-01

    Nuclear electric propulsion has been identified as an enabling technology for future NASA space science missions, such as the Jupiter Icy Moons Orbiter (JIMO) now under study. An important element of the nuclear electric propulsion spacecraft is the power conversion system, which converts the reactor heat to electrical power for use by the ion propulsion system and other spacecraft loads. The electrical integration of the power converter and ion thruster represents a key technical challenge in making nuclear electric propulsion technology possible. This technical hurdle was addressed extensively on December 1, 2003, when a closed- Brayton-cycle power-conversion unit was tested with a gridded ion thruster at the NASA Glenn Research Center. The test demonstrated end-to-end power throughput and marked the first-ever coupling of a Brayton turbo alternator and a gridded ion thruster, both of which are candidates for use on JIMO-type missions. The testing was conducted at Glenn's Vacuum Facility 6, where the Brayton unit was installed in the 3-m-diameter vacuum test port and the ion thruster was installed in the 7.6-m-diameter main chamber.

  3. Image-guided placement of port catheters: is there an increased risk of infection if the port is immediately accessed and used?

    Science.gov (United States)

    Salazar, Gloria; Yeddula, Kalpana; Wicky, Stephan; Oklu, Ramhi; Ganguli, Suvranu; Waltman, Arthur C; Walker, Thomas G; Kalva, Sanjeeva P

    2013-01-01

    To compare complication rates in patients who have port-a-catheters inserted and left accessed for immediate use and those who have ports inserted but not accessed. In this retrospective, IRB-approved study, medical records of patients who received a port catheter between 9/2009 and 2/2010 were reviewed. The data collected included patient demographics, diagnosis, procedure and complications. The patients were categorized into two groups: accessed (patients in whom the port was accessed with a Huber needle for immediate intravenous use and the patient left the procedure area with needle indwelling) and control (patients in whom the ports were not accessed). Complications were classified according to Society of Interventional Radiology guidelines. Results are given as mean ±SD. Statistical analysis was performed with student t test and statistical significance was considered at Pports were placed in 465 patients (Men: 206); 10.7% in the accessed group (n=50, age: 60±13.9) and 89.3% in the control group (n=417, age: 59±13.5). There were no statistically significant differences in patient demographics between the groups. The overall complication rate was 0.6% (n=3). Two complications (hematoma causing skin necrosis and thrombosis of the port) occurred in the control group and one (infection) in the accessed group. Infection rates after procedures were 2% (1/50) in the accessed group and 0% (0/417) in the control group. There was no statistically significant difference in overall complication (P=.1) and infection (P=.1) rates among the groups. Leaving the port accessed immediately after placement does not increase the risk of infection or other complications.

  4. One cubic metre NIST traceable radon test chamber

    International Nuclear Information System (INIS)

    Kotrappa, P.; Stieff, F.

    2008-01-01

    With the availability of the National Inst. of Standards and Technology (NIST) Radon Emanation Standard with a content of ∼5000 Bq of 226 Ra, it is possible to build a flow through a practical radon test chamber. A standard glove box with four gloves and a transfer port is used. Air is pumped through a flow integrator, water jar for humidification and NIST source holder, and into the glove box through a manifold. A derived theoretical expression provides the calculated radon concentration inside the chamber. The calculation includes a derived decay correction due to the large volume and low flow rate of the system. Several calibrated continuous radon monitors and passive integrating electret ion chambers tested in the chamber agreed fairly well with the calculated radon concentrations. The chamber is suitable for handling the calibration of several detectors at the same time. (authors)

  5. Convergence of metropolitan house prices in South Africa: a re-examination using efficient unit root tests

    CSIR Research Space (South Africa)

    Das, Sonali

    2010-01-01

    Full Text Available This paper analyzes whether the Law of One Price (LOOP) holds in the housing market of five metropolitan areas of South Africa, namely Cape Town, Durban, Greater Johannesburg, Port Elizabeth/Uitenhage and Pretoria. The authors test the existence...

  6. The use of Minilabs to improve the testing capacity of regulatory authorities in resource limited settings: Tanzanian experience.

    Science.gov (United States)

    Risha, Peter Gasper; Msuya, Zera; Clark, Malcolm; Johnson, Keith; Ndomondo-Sigonda, Margareth; Layloff, Thomas

    2008-08-01

    The Tanzania Food and Drugs Authority piloted the use of Minilab kits, a thin-layer-chromatographic based drug quality testing technique, in a two-tier quality assurance program. The program is intended to improve testing capacity with timely screening of the quality of medicines as they enter the market. After 1 week training of inspectors on Minilab screening techniques, they were stationed at key Ports-of-Entry (POE) to screen the quality of imported medicines. In addition, three non-Ports-of-Entry centres were established to screen samples collected during Post-Marketing-Surveillance. Standard operating procedures (SOPs) were developed to structure and standardize the implementation process. Over 1200 samples were tested using the Minilab outside the central quality control laboratory (QCL), almost doubling the previous testing capacity. The program contributed to increased regulatory reach and visibility of the Authority throughout the country, serving as a deterrent against entry of substandard medicines into market. The use of Minilab for quality screening was inexpensive and provided a high sample throughput. However, it suffers from the limitation that it can reliably detect only grossly substandard or wrong drug samples and therefore, it should not be used as an independent testing resource but in conjunction with a full-service quality control laboratory capable of auditing reported substandard results.

  7. Test Review: TestDaF

    Science.gov (United States)

    Norris, John; Drackert, Anastasia

    2018-01-01

    The Test of German as a Foreign Language (TestDaF) plays a critical role as a standardized test of German language proficiency. Developed and administered by the Society for Academic Study Preparation and Test Development (g.a.s.t.), TestDaF was launched in 2001 and has experienced persistent annual growth, with more than 44,000 test takers in…

  8. Examining Container Port Resources and Environments to Enhance Competitiveness: A Cross-Country Study from Resource-Based and Institutional Perspectives1

    Directory of Open Access Journals (Sweden)

    Hyuksoo CHO

    2015-09-01

    Full Text Available This study aims to analyze the competitiveness of container ports using a cross-country analysis with theoretical foundations. Tangible and intangible resources are discussed as determinants of container port competitiveness using the resource-based view and the institutional theory. This study analyzes the relationships among six variables: container port competitiveness, traffic volume, quality of infrastructure, linear shipping connectivity, operating efficiency, and institutional influence. This study retrieved country-level data on different indicators and countries from several trade and maritime databases. Structural Equation Modeling (SEM is used to test various hypotheses and to evaluate the casual relationships among six variables. Additionally, Ordinary Least Squares (OLS regression is used to test the moderating effects of institutional influence.

  9. Developing the port of Belawan as a modern and international port

    Science.gov (United States)

    Many, N.

    2018-03-01

    This study discusses the processes of government to pass the port development plan in Indonesia with the Port of Belawan and its port expansion as the study case. The study uses a descriptive approach by reviewing and analyzing some of relevant literature as the sources. It also reviews and examines the port development theoretical concepts and models giving attention to the international hub port models resulted from the previous studies. The international hub port aspects assessed to be further applied and compared to the actual situation of the Port of Belawan. This process draws the conclusion on which concept and model the port classified, followed by some recommendations concerning the necessary actions to be taken. The results show that: (1) The port planning regulated in port master plan is the guideline and foundation to implement the port development; (2) Spatial and zoning plan regulations are very important in the preparation, planning, and implementation of port development; (3) It has not provided the necessary facilities and criteria of the global hub port model has not been met completely. The port is strategic to be completely developed as the regional hub port to compete with the major ports of neighboring countries. Eventually, this study requires further analysis to examine the economic feasibility of the Port of Belawan in more comprehensive way functioning as an international hub port along with the ongoing development of Kuala Tanjung Port to achieve its ultimate objectives, among other things, the port effectiveness, efficiency, and competitiveness.

  10. COMPARATIVE ANALYSIS OF LEADING PORTS OF LATVIA: COMPETITIVENESS OF LIEPAJA PORT

    Directory of Open Access Journals (Sweden)

    Diāna Līduma

    2015-06-01

    Full Text Available There are 10 operating ports in Latvia and 3 of them – Liepaja, Ventspils and Riga ports are regarded as the leading commercial ports. Role of port operation in the economics of region and country is essential from the point of view of employment and entrepreneurship. This is based with data on investment of operation of Latvian ports in GDP, on average it is assessed to be 5-7% annually. In the context of employment, Liepaja Port gives work to 6.9% of human resources of the city. However, concern about the competitiveness of Liepaja Port influenced by the proximity of more developed competitive ports, technical possibilities of the port and dynamics of freight turnover has occurred in recent years. Therewith in framework of this article in the context of such criteria as location of ports and their technical parameters, volumes of freight, specialization and costs of ports, the operation of leading ports of Latvia is intercompared and analyzed by clarifying whether Liepaja Port is competitive among other ports of Latvia. Opinions of port experts on perspectives of port development and statistical data of ports from 2011-2013 are analyzed within the framework of the article. The aim of the research is to clarify the comparative advantages of ports of Latvia. The research revealed that the provision of competitiveness of Liepaja Port is to be related with application of the available free territories, advantages of location in relation to the Scandinavian market, and the necessity to develop the cooperation among ports of Latvia to offer joint freight acquisition, distributions and unified logistics solution and strengthen the position of ports in the circumstances of international competition.

  11. A general method for measuring the scattering matrices of N-port systems

    International Nuclear Information System (INIS)

    Bizarro, J.P.; Pain, M.

    1989-01-01

    Arising from the need to test the multijunctions that will build up the JET (Joint European Torus) lower hybrid antenna, a general model to measure scattering matrices of microwave devices was developed. The model allows for devices with any number of ports and for the use of adaptors between the measuring system and the device under test. Its accuracy can be as good as 1% for waveguide components. (author)

  12. Short-term forecasting of intermodal freight using ANNs and SVR: Case of the Port of Algeciras Bay

    Energy Technology Data Exchange (ETDEWEB)

    Moscoso Lopez, J.A.

    2016-07-01

    Forecasting of future intermodal traffic demand is very important for decision making in ports operations management. The use of accurate prediction tools is an issue that awakens a lot of interest among transport researchers. Intermodal freight forecasting plays an important role in ports management and in the planning of the principal port activities. Hence, the study is carried out under the motivation of knowing that modeling the freight transport flows could facilitate the management of the infrastructure and optimize the resources of the ports facilities. The use of advanced models for freight forecasting is essential to improve the port level-service and competitiveness. In this paper, two forecasting-models are presented and compared to predict the freight volume. The models developed and tested are based on Artificial Neural Networks and Support Vector Machines. Both techniques are based in a historical data and these methods forecast the daily weight of the freight with one week in advance. The performance of the models is evaluated on real data from Ro-Ro freight transport in the Port of Algeciras Bay. This work proposes and compares different approaches to determine the best prediction. In order to select the best model a multicomparison procedure is developed using several statistical test. The results of the assessed models show a promising tool to predict Ro-Ro transport flows with accuracy. (Author)

  13. Multi-port network and 3D finite-element models for accurate transformer calculations: Single-phase load-loss test

    Energy Technology Data Exchange (ETDEWEB)

    Escarela-Perez, R. [Departamento de Energia, Universidad Autonoma Metropolitana, Av. San Pablo 180, Col. Reynosa, C.P. 02200, Mexico D.F. (Mexico); Kulkarni, S.V. [Electrical Engineering Department, Indian Institute of Technology, Bombay (India); Melgoza, E. [Instituto Tecnologico de Morelia, Av. Tecnologico 1500, Morelia, Mich., C.P. 58120 (Mexico)

    2008-11-15

    A six-port impedance network for a three-phase transformer is obtained from a 3D time-harmonic finite-element (FE) model. The network model properly captures the eddy current effects of the transformer tank and frame. All theorems and tools of passive linear networks can be used with the multi-port model to simulate several important operating conditions without resorting anymore to computationally expensive 3D FE simulations. The results of the network model are of the same quality as those produced by the FE program. Although the passive network may seem limited by the assumption of linearity, many important transformer operating conditions imply unsaturated states. Single-phase load-loss measurements are employed to demonstrate the effectiveness of the network model and to understand phenomena that could not be explained with conventional equivalent circuits. In addition, formal deduction of novel closed-form formulae is presented for the calculation of the leakage impedance measured at the high and low voltage sides of the transformer. (author)

  14. Soft-Tissue-Anchored Transcutaneous Port for Long-Term Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Nyman, Rickard; Ekloef, Hampus; Eriksson, Lars-Gunnar; Karlsson, Britt-Marie; Rasmussen, Ib; Lundgren, Dan; Thomsen, Peter

    2005-01-01

    Purpose. A transcutaneous port (T-port) has been developed allowing easy exchange of a catheter, which was fixed inside the device, using the Seldinger technique. The objective of the study was to test the T-port in patients who had percutaneous transhepatic biliary drainage (PTBD). Methods. The T-port, made of titanium, was implanted using local anesthesia in 11 patients (mean age 65 years, range 52-85 years) with biliary duct obstruction (7 malignant and 4 benign strictures). The subcutaneous part of the T-port consisted of a flange with several perforations allowing ingrowth of connective tissue. The T-port allowed catheter sizes of 10 and 12 Fr. Results. All wounds healed uneventfully and were followed by a stable period without signs of pronounced inflammation or infection. It was easy to open the port and to exchange the drainage tube. The patient's quality of life was considerably improved even though several patients had problems with repeated bile leakage due to frequent recurrent obstructions of the tubes. The ports were implanted for a mean time of 9 months (range 2-21 months). Histologic examination in four cases showed that the port was well integrated into the soft tissue. Tilting of the T-port in two cases led to perforation of the skin by the subcutaneous part of the ports, which were removed after 7 and 8 months. Conclusion. The T-port served as an excellent external access to the biliary ducts. The drainage tubes were well fixed within the ports. The quality of life of the patients was considerably improved. Together with improved aesthetic appearance they found it easier to conduct normal daily activities and personal care. However, the problem of recurrent catheter obstruction remained unsolved

  15. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    Science.gov (United States)

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Test Bed for Safety Assessment of New e-Navigation Systems

    Directory of Open Access Journals (Sweden)

    Axel Hahn

    2014-12-01

    Full Text Available New e-navigation strains require new technologies, new infrastructures and new organizational structures on bridge, on shore as well as in the cloud. Suitable engineering and safety/risk assessment methods facilitate these efforts. Understanding maritime transportation as a sociotechnical system allows the application of system-engineering methods. Formal, simulation based and in situ verification and validation of e-navigation technologies are important methods to obtain system safety and reliability. The modelling and simulation toolset HAGGIS provides methods for system specification and formal risk analysis. It provides a modelling framework for processes, fault trees and generic hazard specification and a physical world and maritime traffic simulation system. HAGGIS is accompanied by the physical test bed LABSKAUS which implements a physical test bed. The test bed provides reference ports and waterways in combination with an experimental Vessel Traffic Services (VTS system and a mobile integrated bridge: This enables in situ experiments for technological evaluation, testing, ground research and demonstration. This paper describes an integrated seamless approach for developing new e-navigation technologies starting with simulation based assessment and ending in physical real world demonstrations

  17. Reliability test: X-ray ring exit chambers crotch radiation absorbers. Final report

    International Nuclear Information System (INIS)

    Lynch, D.R.; Morgan, J.

    1999-01-01

    This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. These absorbers are part of the 16 dipole vacuum chambers which comprise the arc sections of the ring. They are located at the intersections (crotch) of the beamline exit ports with the electron beam chamber, and are commonly referred to as crotches. The purpose of these efforts was to demonstrate the reliability of the crotches under operating conditions that the crotches will be subjected to over the entire expected life of the ring. The efforts described include engineering calculations, finite element analysis, conceptual design for a reliability test, test implementation and descriptions, results and conclusions related to these analyses and tests

  18. Two-port access versus four-port access laparoscopic ovarian cystectomy.

    Science.gov (United States)

    Choi, Won-Kyu; Kim, Jang-Kew; Yang, Jung-Bo; Ko, Young-Bok; Nam, Sang-Lyun; Lee, Ki-Hwan

    2014-09-01

    This study was conducted to compare the surgical outcomes between two-port access and four-port access laparoscopic ovarian cystectomy. Four hundred and eighty nine patients who had received two-port access laparoscopic ovarian cystectomy (n=175) and four-port access laparoscopic ovarian cystectomy (n=314) in Chungnam National University Hospital from January 2009 to August 2012 were analyzed retrospectively. The data were compared between the bilaterality of the cysts and cyst diameter of less than 6 cm and 6 cm or more. There were no significant differences in patient's age, parity, body weight, body mass index and history of previous surgery between the two-port and four-port access laparoscopy group. Bilaterality of ovarian cysts was more in fourport access laparoscopy group (13.7% vs. 32.5%, P=0.000). There were no significant differences in operation time, hemoglobin change, hospital stay, adhesiolysis, transfusion, and insertion of hemo-vac between the two-port and four-port access laparoscopy group for size matched compare. However additional analgesics were more in four-port access laparoscopy group for unilateral ovarian cystectomy. Two-port access laparoscopic surgery was feasible and safe for unilateral and bilateral ovarian cystectomy compare with four-port access laparoscopic surgery.

  19. UPTF test 21D counterpart test in the MIDAS test facility

    International Nuclear Information System (INIS)

    Yoon, B. C.; Ah, D. J.; Joo, I. C.; Kwon, T. S.; Park, W. M.; Song, C. H.

    2002-01-01

    This paper describes the experimental results of UPTF Test 21D counterpart tests in the downcomer during the late reflood phase of LBLOCA. The experiments have been performed in the MIDAS test facility using superheated steam and water. The test condition was determined,based on the test results of UPTF Test 21D, by applying the 'modified linear scaling method of 1/4.077 length scale. The tests of ECC direct bypass and void height are performed separately to estimate each phenomena quantitatively. The tests were carried out by varying the injection steam flow rate of intact cold legs widely to investigate the effect of steam flow rate on the direct bypass fraction and void height. In the tests, separate effect tests have been performed in cases of DVI-1,DVI- 2 and DVI-1 and 2 injections to see the direct bypass fraction according to the DVI nozzle combination. From the tests, we found that the fraction of direct ECC bypass and the void height observed in the MIDAS test facility reasonably well agree with those of UPTF test 21- D. It confirms that the applied 'modified linear scaling law' reproduces major thermal hydraulics phenomena in the downcomer during the LBLOCA reflood phase

  20. Analysis of the ITER ECH Upper Port Launcher remote maintenance using virtual reality

    International Nuclear Information System (INIS)

    Elzendoorn, Ben; de Baar, Marco; Chavan, Rene; Goodman, Timothy; Heemskerk, Cock; Heidinger, Roland; Kleefeldt, Klaus; Koning, Jarich; Sanders, Stephen; Spaeh, Peter; Strauss, Dirk; Verhoeven, Toon; Vreede, Fred de

    2009-01-01

    All ITER sub-systems of remote handling (RH) classes 1 and 2 have to be remotely maintainable. The maintenance strategy for these components has to ensure system availability after failure or scheduled maintenance. This paper shows how virtual reality (VR) simulation can be used as a tool to analyze the maintenance process, to predict the mean time to repair and to ensure the RH compatibility of one ITER sub-system, the Upper Port Launcher (UPL) . Special emphasis is put on the development of RH procedures and the identification of tooling requirements. The possibility to simulate RH logistics and repair actions in an early stage of the design process allows for the identification of those maintenance actions that require dedicated tests in the Launcher Handling Test Facility at Karlsruhe. The VR analysis, together with dedicated mock-up tests will demonstrate the RH compatibility of the UPL plug, provide input to the design of the Port Plug maintenance area in the ITER Hot Cell, and support the development of RH maintenance tooling.

  1. 10 CFR Appendix D to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers

    Science.gov (United States)

    2010-01-01

    ... CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. D... the door plane and the loading port. Record the temperature of the water and then the weight of the...

  2. Test report: Electron-proton spectrometer qualification test unit, qualification test

    Science.gov (United States)

    Vincent, D. L.

    1972-01-01

    Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.

  3. Leak testing United States Nuclear Regulatory Commission type b packaging

    International Nuclear Information System (INIS)

    Lacy, K.A.

    1995-01-01

    The Waste Isolation Pilot Plant (WTPP) is a one of its kind research and development facility operated by the Department of Energy, Carlsbad Area Office. Located in southeastern New Mexico, the WTPP is designed to demonstrate the safe, permanent disposal of transuranic (TRU) radioactive nuclear waste, accumulated from 40 years of nuclear weapons production. Before the waste can be disposed of, it must first be safely transported from generator storage sites to the WIPP. To accomplish this, the TRUPACT-II was designed and fabricated. This double containment, non-vented waste packaging successfully completed a rigorous testing program, and in 1989 received a Certificate of Compliance (C of C) from the Nuclear Regulatory Commission (NRC). Currently, the TRUPACT-II is in use at Idaho National Engineering Laboratory to transport waste on site for characterization. The DOE/CAO is responsible for maintaining the TRUPACT-II C of C. The C of C requires performance of nondestructive examination (NDE), e.g., visual testing (VT), dimensional inspections, Liquid Dye Penetrant testing (PT), and Helium Leak Detection (HLD). The Waste Isolation Division (WID) uses HLD for verification of the containment integrity. The following HLD tests are performed on annual basis or when required, i.e. repairs or component replacement: (1) fabrication verification leak tests on both the outer containment vessel (OCV) and the inner containment vessel (ICV); (2) assembly verification leak tests on the OCV and ICV upper main o-rings; and (3) assembly verification leak tests on the OCV and the ICV vent port plugs. These tests are addressed in detail as part of this presentation

  4. Computer-Based Testing: Test Site Security.

    Science.gov (United States)

    Rosen, Gerald A.

    Computer-based testing places great burdens on all involved parties to ensure test security. A task analysis of test site security might identify the areas of protecting the test, protecting the data, and protecting the environment as essential issues in test security. Protecting the test involves transmission of the examinations, identifying the…

  5. Green Port / Eco Port Project - Applications and Procedures in Turkey

    Science.gov (United States)

    Akgul, Burak

    2017-12-01

    As being the heartlands of international trade, sea ports are the junction points of land and sea routes. The growth of global trade has led to the development of number and capacity as well as the service quality of ports. The policies and procedures applied during construction, operation and development of ports under development with environmental considerations scope has evolved in accordance with the needs of global trends. Although maritime transportation provides the most ecofriendly transportation method, the reduction of potential environmental threats and continuous improvement of ports and their vicinity is paramount from environmental concerns with regards to the international environmental standards. In the context of the study, national and international legal regulations governing the control of the environmental impacts of the activity groups causing pollution in Turkey based sea ports were viewed. In addition, the models applied during the measurement and documentation of environmental impacts were investigated. The most important aspects in terms of the effectiveness of the environmental management models are legal regulations. However, the standards applied at the ports without any legal obligation, such as EcoPorts applications, ISO 14001 standard, and the EMAS (Eco-Management and Audit Scheme) were sought in the scope of the study. The boundaries of the study were determined as the EU based Environmental Management Systems and the Green Port/Eco Port Project which is being administered by the Turkish Ministry of Transport, Maritime and Communication. “Marport”, which is Turkey’s first certified Green Port / Eco Port is designated as the experimental study site. In addition, the provisions in the ports of ESPO member countries are approached in order to compare the effectiveness and applicability of Green Port / Eco Port Project.

  6. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-05-26

    Disclosed are various embodiments for connectors used with electronic devices, such as input and/or output ports to connect peripheral equipment or accessories. More specifically, various flat-port are provided that can be used in place of standard connectors including, but not limited to, audio jacks and Universal Serial Bus (USB) ports. The flat-port connectors are an alternate connection design to replace the traditional receptacle port (female-port), making the device more sealed creation more dust and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot of space and contribute to the increase thickness of the device. The flat-port receptacle improves the overall appearance of the device and makes it more resistant to dust and water.

  7. Intra-arterial port implantation for intra-arterial chemotherapy : comparison between PIPS(Percutaneously Implantable Port System) and port system

    International Nuclear Information System (INIS)

    Yoon, Sang Jin; Shim, Hyung Jin; Jung, Hun Young; Choi, Yong Ho; Kim, Yang Soo; Song, In Sup; Kwak, Byung Kook

    1999-01-01

    To compare the techniques and complications of intra-arterial port implantation for intra-arterial chemotherapy between PIPS and the port system. For intra-arterial port implantation, 27 cases in 27 patients were retrospectively evaluated using PIPS(PIPS-200, William Cook Europe, Denmark) while for 21 cases in 19 patients a pediatric venous port system(Port-A-Cath, 5.8F, SIMS Deltec, U. S. A.) was used. All intra-arterial port implantation was performed percuteneously in an angiographic ward. Hepatocellular carcinoma was diagnosed in 18 patients and hepatic metastasis in 16. Peripheral cholangiocarcinoma, and pancreatic gastric, ovarian, renal cell and colon carcinoma were included. We compared the techniques and complications between PIPS and the port system. The follow up period ranged from 23 to 494(mean, 163) days in PIPS and from 12 to 431(mean, 150) days in the port system. In all cases, intra-arterial port implantations were technically successful. Port catheter tips were located in the common hepatic artery(n=8), proper hepatic artery(n=7), right hepatic artery(n=5), gastroduodenal artery(n=2), left hepatic artery(n=1), pancreaticoduodenal artery(n=1), inferior mesenteric artery(n=1), lumbar artery(n=1), and renal artery(n=1) in PIPS, and in the proper hepatic artery(n=6), gastroduodenal artery(n=6), common hepatic artery(n=3), right hepatic artery(n=4), inferior mesenteric artery(n=1), and internal iliac artery(n=1) in the port system. Port chambers were buried in infrainguinal subcutaneous tissue. Using PIPS, complications developed in seven cases(25.9%) and of these, four (57.1%) were catheter or chamber related. In the port system, catheter or chamber related complications developed in four cases(19.0%). Because PIPS and the port system have relative merits and demetrits, successful intra-arterial port implantation is possible if equipment is properly selected

  8. Port Stakeholder Summit: Advancing More Sustainable Ports (April 2014)

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  9. Ports Initiative

    Science.gov (United States)

    EPA's Ports Initiative works in collaboration with the port industry, communities, and government to improve environmental performance and increase economic prosperity. This effort helps people near ports breath cleaner air and live better lives.

  10. Design of Jet lower hybrid current drive generator and operation of high power test bed

    International Nuclear Information System (INIS)

    Dobbing, J.A.; Bosia, G.; Brandon, M.; Gammelin, M.; Gormezano, C.; Jacquinot, J.; Jessop, G.; Lennholm, M.; Pain, M.; Sibley, A.

    1989-01-01

    The JET Lower Hybrid Current Drive (LHCD) generator consists of 24 klystrons each rated for 650 KW operating at 3.7 GHz, giving a nominal generator power of 15.6 MW for 10 seconds or 12 MW for 20 seconds. This power will be transmitted through 24 waveguides to a phased array launcher on one of the main ports of the JET machine. In addition, two klystrons are currently being operated on a high power test bed to establish reliable operation of the generators components and test high power microwave components prior to their installation

  11. Validation of US3D for Capsule Aerodynamics using 05-CA Wind Tunnel Test Data

    Science.gov (United States)

    Schwing, Alan

    2012-01-01

    Several comparisons of computational fluid dynamics to wind tunnel test data are shown for the purpose of code validation. The wind tunnel test, 05-CA, uses a 7.66% model of NASA's Multi-Purpose Crew Vehicle in the 11-foot test section of the Ames Unitary Plan Wind tunnel. A variety of freestream conditions over four Mach numbers and three angles of attack are considered. Test data comparisons include time-averaged integrated forces and moments, time-averaged static pressure ports on the surface, and Strouhal Number. The applicability of the US3D code to subsonic and transonic flow over a bluff body is assessed on a comprehensive data set. With close comparison, this work validates US3D for highly separated flows similar to those examined here.

  12. Radioisotope thermoelectric generator licensed hardware package and certification tests

    International Nuclear Information System (INIS)

    Goldmann, L.H.; Averette, H.S.

    1994-01-01

    This paper presents the Licensed Hardware package and the Certification Test portions of the Radioisotope Thermoelectric Generator Transportation System. This package has been designed to meet those portions of the Code of Federal Regulations (10 CFR 71) relating to ''Type B'' shipments of radioactive materials. The detailed information for the anticipated license is presented in the safety analysis report for packaging, which is now in process and undergoing necessary reviews. As part of the licensing process, a full-size Certification Test Article unit, which has modifications slightly different than the Licensed Hardware or production shipping units, is used for testing. Dimensional checks of the Certification Test Article were made at the manufacturing facility. Leak testing and drop testing were done at the 300 Area of the US Department of Energy's Hanford Site near Richland, Washington. The hardware includes independent double containments to prevent the environmental spread of 238 Pu, impact limiting devices to protect portions of the package from impacts, and thermal insulation to protect the seal areas from excess heat during accident conditions. The package also features electronic feed-throughs to monitor the Radioisotope Thermoelectric Generator's temperature inside the containment during the shipment cycle. This package is designed to safely dissipate the typical 4500 thermal watts produced in the largest Radioisotope Thermoelectric Generators. The package also contains provisions to ensure leak tightness when radioactive materials, such as a Radioisotope Thermoelectric Generator for the Cassini Mission, planned for 1997 by the National Aeronautics and Space Administration, are being prepared for shipment. These provisions include test ports used in conjunction with helium mass spectrometers to determine seal leakage rates of each containment during the assembly process

  13. Verification Test of Hydraulic Performance for Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Jun; Kim, Jae Shin; Ryu, In Wan; Ko, Bok Seong; Song, Keun Myung [Samjin Ind. Co., Seoul (Korea, Republic of)

    2010-01-15

    According to this project, basic design for prototype pump and model pump of reactor coolant pump and test facilities has been completed. Basic design for prototype pump to establish structure, dimension and hydraulic performance has been completed and through primary flow analysis by computational fluid dynamics(CFD), flow characteristics and hydraulic performance have been established. This pump was designed with mixed flow pump having the following design requirements; specific velocity(Ns); 1080.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 3115m{sup 3}/h, total head ; 26.3m, pump speed; 1710rpm, pump efficiency; 77.0%, Impeller out-diameter; 349mm, motor output; 360kw, design pressure; 17MPaG. The features of the pump are leakage free due to no mechanical seal on the pump shaft which insures reactor's safety and law noise level and low vibration due to no cooling fan on the motor which makes eco-friendly product. Model pump size was reduced to 44% of prototype pump for the verification test for hydraulic performance of reactor coolant pump and was designed with mixed flow pump and canned motor having the following design requirements; specific speed(NS); 1060.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 539.4m{sup 3}/h, total head; 21.0m, pump speed; 3476rpm, pump efficiency; 72.9%, Impeller out-diameter; 154mm, motor output; 55kw, design pressure; 1.0MPaG. The test facilities were designed for verification test of hydraulic performance suitable for pump performance test, homologous test, NPSH test(cavitation), cost down test and pressure pulsation test of inlet and outlet ports. Test tank was designed with testing capacity enabling up to 2000m{sup 3}/h and design pressure 1.0MPaG. Auxiliary pump was designed with centrifugal pump having capacity; 1100m{sup 3}/h, total head; 42.0m, motor output; 190kw

  14. Fabrication and tests and RF control of the superconducting resonators of the Saclay heavy ion LINAC

    International Nuclear Information System (INIS)

    Cauvin, B.; Coret, M.; Fouan, J.P.; Girard, J.; Girma, J.L.; Leconte, P.; Lussignol, Y.; Moreau, R.; Passerieux, J.P.; Ramstein, G.; Wartski, L.

    1987-01-01

    Two types of niobium superconducting resonators used in the Saclay linac are discussed. The outer cylinder and RF ports are identical for the two designs, but internal structures are different: full wave helix with three gaps behavior; or half wave with two gaps behavior. All cavities (34 full wave, 16 half) were tested for field and mounted in the machine cryostats. Cavity fabrication and performance are summarized. Vibration tests and Rf control are described. It is argued that helix resonators can overcome problems due to vibration. The very low lock out time percentage measured in an acceleration test with 21 cavities supports this confidence

  15. The design and implementation of BESIII online test farm

    International Nuclear Information System (INIS)

    Liu Zhixu; Liu Feng; Zhu Kejun; Li Fei

    2004-01-01

    Computing Farms are used widely in the field of high-energy physics. As the increase of performance and the relative lower price, with the open source operating system Linux and many other free software available, PC is playing a more and more important role in the computing farms. In this letter, the design and implementation of the BESIII online data acquisition system test farm with PC, Linux and other free software are presented. This system can be ported to the real online system easily. It can be applied to other purpose farm, such as a physics analysis farm, too. (authors)

  16. SRF cavity testing using a FPGA Self Excited Loop

    CERN Document Server

    Ben-Zvi, Ilan

    2018-01-01

    This document provides a detailed description of procedures for very-high precision calibration and testing of superconducting RF cavities using digital Low-Level RF (LLRF) electronics based on Field Programmable Gate Arrays (FPGA). The use of a Self-Excited Loop with an innovative procedure for fast turn-on allows the measurement of the forward, reflected and transmitted power from a single port of the directional coupler in front of the cavity, thus eliminating certain measurement errors. Various procedures for measuring the quality factor as a function of cavity fields are described, including a single RF pulse technique. Errors are estimated for the measurements.

  17. Revisiting port pricing : a proposal for seven port pricing principles

    NARCIS (Netherlands)

    Van Den Berg, R.; De Langen, P.W.; Van Zuijlen, P.C.J.

    2017-01-01

    A review of seven large landlord port authorities around the world reveals a notable diversity of pricing structures. While port authorities increasingly act as commercial undertakings, port pricing often seems to be not driven by commercial considerations. In this paper, we argue that ports can be

  18. Surface stabilization and revegetation test plots

    International Nuclear Information System (INIS)

    Sackschewsky, M.R.; Kemp, C.J.; Hayward, W.M.

    1993-09-01

    Westinghouse Hanford Company Decommissioning and Decontamination Engineering Group and Environmental Technology and Assessment Groups are developing new technologies to improve revegetation techniques for interim stabilization control over underground waste sites within the Radiation Area Remedial Action Program. Successful revegetation is an integral aspect of waste isolation strategy. Unfortunately, revegetation can be very difficult to achieve on the Hanford Site due to several factors: low annual precipitation, unpredictable timing of precipitation, low fertility of available soils, and coarse physical texture of soils covering waste sites. The tests in this report were performed during fiscal years 1992 and 1993 and include the use of two soil sealants in combination with bare soil and a soil/compost mixture and a comparison of a wheatgrass mixture and a native seed mixture. Hydroprobe access ports were placed in one-half of the test plots and moisture data was collected. Soil fertility and plant community characteristics were monitored during the two years of the test. During the first year all sites with compost provided additional fertility and retained greater amounts of soil moisture than noncomposted sites. The use of Enduraseal soil fixative provided greater soil moisture than the use of Aerospray-77 soil fixative. During the second year the use of compost and soil fixative's had a lesser effect on soil moisture. During late summer periods all treatments had very similar soil moisture profiles. The use of compost greatly increased vegetative cover and soil fertility in comparison to sites that had no compost added. Testing of the seed mixtures found that Siberian wheatgrass and Sandberg's bluegrass were the most dominant of the seeded species observed. All plots exhibited a dominant plant cover of volunteer cheatgrass. Biomass production was significantly greater on plots with compost than on the noncomposted plots

  19. Influence of Port Policy on the Development of Croatian Container Ports

    Directory of Open Access Journals (Sweden)

    Čedomir Dundović

    2002-03-01

    Full Text Available It is important to consider the port development throughoutthe world from the aspect of economical, transport and portpolicy and their mutual impact on commerce and efficiency ofports. By examining such relations in the context of developmentof the Croatian container ports, it is possible to define reasonsfor lagging behind of Croatian ports compared to theworld movements.The main reason for the negative trend of development ofCroatian container ports lies in the non-existence of adequatemeasures of transport, maritime and port policy. Analysis ofstatistics over the past decade and comparison of structure andvolume of the general cargo traffic in the Rijeka port and theneighbouring ports in the area of North Adriatic are both showingsignificant size discrepancy and uncompetitiveness of theCroatian port. Disturbances that have brought to such a situationresult from inadequate port policy and non-harmonisedactivities between various modes of transport.In order to overcome such situation, the authors suggest determiningof clear tasks, goals and measures of the port policythat have to be undertaken so that the Croatian policy could becompatible with the main aspects, development tendencies andmeasures of theE U port policy.

  20. Manufacture, testing and assembly preparation of the JET vacuum vessel

    International Nuclear Information System (INIS)

    Arbez, J.; Baeumel, S.; Dean, J.R.; Duesling, G.; Froger, C.; Hemmerich, J.L.; Walravens, M.; Walter, K.; Winkel, T.

    1983-01-01

    To reach the target pressure of 10 -9 mbar, JET's double-walled Inconel vacuum vessel is being manufactured and assembled in clean conditions and with meticulous leak detection. Each octant (1/8 of the torus) is baked in an oven to 520 0 C and leak tested at 350 0 C to reveal leaks as small as 10 -9 mbar l/s, which are repaired. In service the vessel will be baked periodically to 500 0 C by CO 2 passing between its walls. The single-walled ports will be electrically heated. (author)

  1. Hybrid rocket motor testing at Nammo Raufoss A/S

    Science.gov (United States)

    Rønningen, Jan-Erik; Kubberud, Nils

    2005-08-01

    Hybrid rocket motor technology and the use of hybrid rockets have gained increased interest in recent years in many countries. A typical hybrid rocket consists of a tank containing the oxidizer in either liquid or gaseous state connected to the combustion chamber containing an injector, inert solid fuel grain and nozzle. Nammo Raufoss A/S has for almost 40 years designed and produced high-performance solid propellant rocket motors for many military missile systems as well as solid propellant rocket motors for civil space use. In 2003 an in-house technology program was initiated to investigate and study hybrid rocket technology. On 23 September 2004 the first in-house designed hybrid test rocket motor was static test fired at Nammo Raufoss Test Center. The oxidizer was gaseous oxygen contained in a tank pressurized to 10MPa, flow controlled through a sonic orifice into the combustion chamber containing a multi port radial injector and six bore cartridge-loaded fuel grain containing a modified HTPB fuel composition. The motor was ignited using a non-explosive heated wire. This paper will present what has been achieved at Nammo Raufoss since the start of the program.

  2. Towards Sustainable ASEAN Port Development: Challenges and Opportunities for Vietnamese Ports

    Directory of Open Access Journals (Sweden)

    Saeyeon Roh

    2016-06-01

    Full Text Available Sustainability agendas are challenging port authorities around the world to find ways of operating and managing their ports efficiently and effectively in terms of economic, social, as well as environmental development. In this respect, governments in ASEAN countries have been implementing various green activities seeking to reduce the environmental impact of shipping and related activities. In this connection, most studies in the existing literature mainly focus on the environmental aspects of sustainable development and have not clearly explained what sustainable port development exactly entails. Furthermore, most of these studies emphasized on the impact of port development and overlooked what factors influence sustainable port development. To address these gaps, this research aim to explore the main factors shaping sustainable port development. This was conducted through a comprehensive review of related literature as well as confirmatory in-depth interviews with port authorities. As a result, findings from this research would help identify key elements of sustainable port development from port authorities’ perspective. The challenges, opportunities and managerial implications for Vietnamese ports are also discussed accordingly.

  3. Gas-phase decontamination demonstration on PORTS cell X-25-4-2. Final technology status report

    International Nuclear Information System (INIS)

    Riddle, R.J.

    1997-09-01

    The Long-Term, Low Temperature (LTLT) process is a gas-phase in situ decontamination technique which has been tested by LMES/K-25 personnel on the laboratory scale with promising results. The purpose of the Gas-Phase Decontamination Demonstration at PORTS was to evaluate the LTLT process on an actual diffusion cascade cell at conditions similar to those used in the laboratory testing. The demonstration was conducted on PORTS diffusion cell X-25-4-2 which was one of the X-326 Building cells which was permanently shutdown as part of the Suspension of HEU Production at PORTS. The demonstration full-scale test consisted of rendering the cell leak-tight through the installation of Dresser seals onto the process seals, exposing the cell to the oxidants ClF 3 and F 2 for a period of 105 days and evaluating the effect of the clean-up treatment on cell samples and coupons representing the major diffusion cascade materials of construction. The results were extrapolated to determine the effectiveness of LTLT decontamination over the range of historical uranium isotope assays present in the diffusion complex. It was determined that acceptable surface contamination levels could be obtained in all of the equipment in the lower assay cascades which represents the bulk of the equipment contained in the diffusion complex

  4. Port-Wine Stains

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Port-Wine Stains KidsHealth / For Parents / Port-Wine Stains What's ... Manchas de vino de oporto What Are Port-Wine Stains? A port-wine stain is a type ...

  5. Testing Practices and Attitudes Toward Tests and Testing: An International Survey

    Czech Academy of Sciences Publication Activity Database

    Evers, A.; McCormick, C. M.; Hawley, L. R.; Muñiz, J.; Balboni, G.; Bartram, D.; Boben, D.; Egeland, J.; El-Hassan, K.; Fernández-Hermida, J.R.; Fine, S.; Frans, Ö.; Gintiliéne, G.; Hagemeister, C.; Halama, P.; Iliescu, D.; Jaworowska, A.; Jiménez, P.; Manthouili, M.; Matesic, K.; Michaelsen, L.; Mogaji, A.; Morley-Kirk, J.; Rózsa, S.; Rowlands, L.; Schittekatte, M.; Sümer, H.C.; Suwartono, T.; Urbánek, Tomáš; Wechsler, S.; Zelenevska, T.; Zanev, S.; Zhang, J.

    2017-01-01

    Roč. 17, č. 2 (2017), s. 158-190 ISSN 1530-5058 Institutional support: RVO:68081740 Keywords : psychological testing * testing practices * test use * International Test Commission * European Federation of Psychologists' Associations Subject RIV: AN - Psychology OBOR OECD: Psychology (including human - machine relations)

  6. Experimental and numerical investigation of the fluid flow in a side-ported rotary engine

    International Nuclear Information System (INIS)

    Fan, Baowei; Pan, Jianfeng; Tang, Aikun; Pan, Zhenhua; Zhu, Yuejin; Xue, Hong

    2015-01-01

    Highlights: • An optical side-ported rotary engine test bed has been set up and tested by PIV. • A three-dimensional dynamic simulation model is established. • Experiment and numerical simulation are combined to study the flow mechanisms. • A counterclockwise flow pattern was found in the combustion chamber in the experiment. • The effect of various parameters on the flow field is studied by numerical simulation. - Abstract: The side-ported rotary engine is a potential alternative to the reciprocating engine because of its favorable performance at low speed. The performance of side-ported rotary engines is strongly influenced by the flow field in the combustion chamber. In this study, an optical side-ported rotary engine test-bed was built and PIV was employed to measure the flow field in the rotor housing central plane. From experiment results, a counterclockwise swirl was detected in the rotor housing central plane. Meanwhile, a three-dimensional dynamic mesh and turbulent flow model was integrated and simulated using the Fluent CFD software. The three-dimensional dynamic simulation model was validated by comparison with experimental results. In addition, the effect of three major parameters on the flow field in the combustion chamber, namely rotating speed, intake pressure and intake angle were numerically investigated. The results show that a swirl forms in the middle and front of the combustion chamber during the intake stroke under low rotating speed. This is in line with the swirl detected in the rotor housing central plane though the PIV experiment at 600 rpm. Furthermore, the flow field, volume coefficient and average turbulence kinetic energy in the combustion chamber were studied in detail by varying rotating speed, intake pressure and intake angle

  7. Learning software testing with Test Studio

    CERN Document Server

    Madi, Rawane

    2013-01-01

    Learning Software Testing with Test Studio is a practical, hands-on guide that will help you get started with Test Studio to design your automated solution and tests. All through the book, there are best practices and tips and tricks inside Test Studio which can be employed to improve your solution just like an experienced QA.If you are a beginner or a professional QA who is seeking a fast, clear, and direct to the point start in automated software testing inside Test Studio, this book is for you. You should be familiar with the .NET framework, mainly Visual Studio, C#, and SQL, as the book's

  8. Cargo container inspection test program at ARPA's Nonintrusive Inspection Technology Testbed

    Science.gov (United States)

    Volberding, Roy W.; Khan, Siraj M.

    1994-10-01

    An x-ray-based cargo inspection system test program is being conducted at the Advanced Research Project Agency (ARPA)-sponsored Nonintrusive Inspection Technology Testbed (NITT) located in the Port of Tacoma, Washington. The test program seeks to determine the performance that can be expected from a dual, high-energy x-ray cargo inspection system when inspecting ISO cargo containers. This paper describes an intensive, three-month, system test involving two independent test groups, one representing the criminal smuggling element and the other representing the law enforcement community. The first group, the `Red Team', prepares ISO containers for inspection at an off-site facility. An algorithm randomly selects and indicates the positions and preparation of cargoes within a container. The prepared container is dispatched to the NITT for inspection by the `Blue Team'. After in-gate processing, it is queued for examination. The Blue Team inspects the container and decides whether or not to pass the container. The shipment undergoes out-gate processing and returns to the Red Team. The results of the inspection are recorded for subsequent analysis. The test process, including its governing protocol, the cargoes, container preparation, the examination and results available at the time of submission are presented.

  9. Application of an In-Line Contamination Monitoring Unit to the AHT-64 Hydraulic Test Stand.

    Science.gov (United States)

    1981-06-04

    suction return connection port will require the operator to secuire same from a squatting position. The present stowage arrangement on the test stand... SPC FC sample~~~ Iepal" -a *Tpoa _______Rate 7 eo3,t Sq,’ TPc owe te - U Enciosure ULeeds & Northrup N’AFC- 92- 1 0 Typical Plumbing Connections for

  10. Fewer-than-four ports versus four ports for laparoscopic cholecystectomy.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Vaughan, Jessica; Rossi, Michele; Davidson, Brian R

    2014-02-20

    Traditionally, laparoscopic cholecystectomy is performed using two 10-mm ports and two 5-mm ports. Recently, a reduction in the number of ports has been suggested as a modification of the standard technique with a view to decreasing pain and improving cosmesis. The safety and effectiveness of using fewer-than-four ports has not yet been established. To assess the benefits (such as improvement in cosmesis and earlier return to activity) and harms (such as increased complications) of using fewer-than-four ports (fewer-than-four-ports laparoscopic cholecystectomy) versus four ports in people undergoing laparoscopic cholecystectomy for any reason (symptomatic gallstones, acalculous cholecystitis, gallbladder polyp, or any other condition). We searched the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2013), MEDLINE, EMBASE, Science Citation Index Expanded, and the World Health Organization International Clinical Trials Registry Platform portal to September 2013. We included all randomised clinical trials comparing fewer-than-four ports versus four ports, that is, with standard laparoscopic cholecystectomy that is performed with two ports of at least 10-mm incision and two ports of at least 5-mm incision. Two review authors independently identified the trials and extracted the data. We analysed the data using both the fixed-effect and the random-effects models. For each outcome, we calculated the risk ratio (RR) or mean difference (MD) with 95% confidence intervals (CI) based on intention-to-treat analysis, whenever possible. We found nine trials with 855 participants that randomised participants to fewer-than-four-ports laparoscopic cholecystectomy (n = 427) versus four-port laparoscopic cholecystectomy (n = 428). Most trials included low anaesthetic risk participants undergoing elective laparoscopic cholecystectomy. Seven of the nine trials used a single port laparoscopic cholecystectomy and the remaining two trials used three-port laparoscopic

  11. Detailed Design and Fabrication Method of the ITER Vacuum Vessel Ports

    International Nuclear Information System (INIS)

    Hee-Jae Ahn; Kwon, T.H.; Hong, Y.S.

    2006-01-01

    The engineering design of the ITER vacuum vessel (VV) has been progressed by the ITER International Team (IT) with the cooperation of several participant teams (PT). The VV and ports are the components allocated to Korea for the construction of the ITER. Hyundai Heavy Industries has been involved in the structural analysis, detailed design and development of the fabrication method of the upper and lower ports within the framework of the ITER transitional arrangements (ITA). The design of the port structures has been investigated to validate and to improve the conceptual designs of the ITER IT and other PT. The special emphasis was laid on the flange joint between the port extension and the in-port plug to develop the design of the upper port. The modified design with a pure friction type flange with forty-eight pieces of bolts instead of the tangential key is recommended. Furthermore, the alternative flange designs developed by the ITER IT have been analyzed in detail to simplify the lip seal maintenance into the port flange. The structural analyses of the lower RH port have been also performed to verify the capacity for supporting the VV. The maximum stress exceeds the allowable value at the reinforcing block and basement. More elaborate local models have been developed to mitigate the stress concentration and to modify the component design. The fabrication method and the sequence of the detailed fabrication for the ports are developed focusing on the cost reduction as well as the simplification. A typical port structure includes a port stub, a stub extension and a port extension with a connecting duct. The fabrication sequence consists of surface treatment, cutting, forming, cleaning, welding, machining, and non-destructive inspection and test. Tolerance study has been performed to avoid the mismatch of each fabricated component and to obtain the suitable tolerances in the assembly at the shop and site. This study is based on the experience in the fabrication of

  12. Energy Systems Test Area (ESTA) Battery Test Operations User Test Planning Guide

    Science.gov (United States)

    Salinas, Michael

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTA Battery Test Operations. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  13. Open test assembly (OTA) shear demonstration testing work/test plan

    International Nuclear Information System (INIS)

    Hiller, S.W.

    1998-01-01

    This document describes the development testing phase associated with the OTA Shear activity and defines the controls to be in place throughout the testing. The purpose of the OTA Shear Program was to provide equipment that is needed for the processing of 40 foot long, sodium wetted, irradiated core components previously used in the FFTF reactor to monitor fuel and materials tests. There are currently 15 of these OTA test stalks located in the Test Assembly Conditioning Station (TACS) inerted vault. These need to be dispositioned for a shutdown mission to eliminate this highly activated, high dose inventory prior to turnover to the ERC since they must be handled by remote operations. These would also need to be dispositioned for a restart mission to free up the vault they currently reside in. The waste handling and cleaning equipment in the J33M Cell was designed and built for the handling of reactor components up to the standard 12 foot length. This program will provide the equipment to the IEM Cell to remotely section the OTAS into pieces less than 12 feet in length to allow for the necessary handling and cleaning operations required for proper disposition. Due to the complexity of all operations associated with remote handling, the availability of the IEM Cell training facility, and the major difficulty with reworking contaminated equipment, it was determined that preliminary testing of the equipment was desirable, This testing activity would provide the added assurance that the equipment will operate as designed prior to performance of the formal Acceptance Test Procedure (ATP) at the IEM Cell, This testing activity will also allow for some operator familiarity and procedure checkout prior to actual installation into the IEM Cell. This development testing will therefore be performed at the conclusion of equipment fabrication and prior to transfer of the equipment to the 400 Area

  14. Underground Nuclear Testing Program, Nevada Test Site

    International Nuclear Information System (INIS)

    1975-09-01

    The Energy Research and Development Administration (ERDA) continues to conduct an underground nuclear testing program which includes tests for nuclear weapons development and other tests for development of nuclear explosives and methods for their application for peaceful uses. ERDA also continues to provide nuclear explosive and test site support for nuclear effects tests sponsored by the Department of Defense. This Supplement extends the Environmental Statement (WASH-1526) to cover all underground nuclear tests and preparations for tests of one megaton (1 MT) or less at the Nevada Test Site (NTS) during Fiscal Year 1976. The test activities covered include numerous continuing programs, both nuclear and non-nuclear, which can best be conducted in a remote area. However, if nuclear excavation tests or tests of yields above 1 MT or tests away from NTS should be planned, these will be covered by separate environmental statements

  15. Implementation of Moderator Circulation Test Temperature Measurement System

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Yeong Muk; Hong, Seok Boong; Kim, Min Seok; Choi, Hwa Rim [KAERI, Daejeon (Korea, Republic of); Kim, Hyung Shin [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    Moderator Circulation Test(MCT) facility is 1/4 scale facility designed to reproduce the important characteristics of moderator circulation in a CANDU6 calandria under a range of operating conditions. MCT is an equipment with 380 acrylic pipes instead of the heater rods and a preliminary measurement of velocity field using PIV(Particle Image Velocimetry) is performed under the iso-thermal test conditions. The Korea Atomic Energy Research Institute (KAERI) started implementation of MCT Temperature Measurement System (TMS) using multiple infrared sensors. To control multiple infrared sensors, MCT TMS is implemented using National Instruments (NI) LabVIEW programming language. The MCT TMS is implemented to measure sensor data of multiple infrared sensors using the LabVIEW. The 35 sensor pipes of MCT TMS are divided into 2 ports to meet the minimum measurement time of 0.2 seconds. The software of MCT TMS is designed using collection function and processing function. The MCT TMS has the function of monitoring the states of multiple infrared sensors. The GUI screen of MCT TMS is composed of sensor pipe categories for user.

  16. Implementation of Moderator Circulation Test Temperature Measurement System

    International Nuclear Information System (INIS)

    Lim, Yeong Muk; Hong, Seok Boong; Kim, Min Seok; Choi, Hwa Rim; Kim, Hyung Shin

    2016-01-01

    Moderator Circulation Test(MCT) facility is 1/4 scale facility designed to reproduce the important characteristics of moderator circulation in a CANDU6 calandria under a range of operating conditions. MCT is an equipment with 380 acrylic pipes instead of the heater rods and a preliminary measurement of velocity field using PIV(Particle Image Velocimetry) is performed under the iso-thermal test conditions. The Korea Atomic Energy Research Institute (KAERI) started implementation of MCT Temperature Measurement System (TMS) using multiple infrared sensors. To control multiple infrared sensors, MCT TMS is implemented using National Instruments (NI) LabVIEW programming language. The MCT TMS is implemented to measure sensor data of multiple infrared sensors using the LabVIEW. The 35 sensor pipes of MCT TMS are divided into 2 ports to meet the minimum measurement time of 0.2 seconds. The software of MCT TMS is designed using collection function and processing function. The MCT TMS has the function of monitoring the states of multiple infrared sensors. The GUI screen of MCT TMS is composed of sensor pipe categories for user

  17. To test or not to test

    DEFF Research Database (Denmark)

    Rochon, Justine; Gondan, Matthias; Kieser, Meinhard

    2012-01-01

    Background: Student's two-sample t test is generally used for comparing the means of two independent samples, for example, two treatment arms. Under the null hypothesis, the t test assumes that the two samples arise from the same normally distributed population with unknown variance. Adequate...... control of the Type I error requires that the normality assumption holds, which is often examined by means of a preliminary Shapiro-Wilk test. The following two-stage procedure is widely accepted: If the preliminary test for normality is not significant, the t test is used; if the preliminary test rejects...... the null hypothesis of normality, a nonparametric test is applied in the main analysis. Methods: Equally sized samples were drawn from exponential, uniform, and normal distributions. The two-sample t test was conducted if either both samples (Strategy I) or the collapsed set of residuals from both samples...

  18. Evaluation report on SCTF Core-III Test S3-22

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Iguchi, Tadashi; Iwamura, Takamichi; Akimoto, Hajime; Ohnuki, Akira; Abe, Yutaka; Murao, Yoshio; Adachi, Hiromichi.

    1991-07-01

    Two tests (Tests S3-20 and S3-22) were conducted with JAERI's Slab Core Test Facility (SCTF) Core-III in order to investigate water break-through and core cooling behaviors under the intermittent ECC water delivery from the hot legs to one location in the upper plenum and the alternate ECC water delivery to two locations in the upper plenum during reflooding, respectively. This report presents an analysis on Test S3-22 (the alternate case). Subcooled ECC water was injected alternately just above the upper core support plate above Bundles 7 and 8 and Bundles 3 and 4. The total injection rate from both injection ports was the same as that in SCTF Test S3-20 and Test S3-13. Analyzing the test data together with those of Tests S3-13 and S3-20 the following has been found: (1) Alternate break-through occurred immediately corresponding to the alternate ECC water injection except for one period, during which no break-through was observed. However, there observed a difference in break-through behavior that break-through was strong above the low power region, whereas weak above the high power region. (2) Although its break-through behavior was different, nearly the same core cooling as in the continuous or intermittent ECC water delivery case was observed except for the period around quench. (3) Around quench time, degraded core cooling comparing to the continuous or intermittent ECC water delivery case was observed. That is, quench time at the midplane level of the present test was 35 s later than in the continuous case. This is considered to result from decrease in core water inventory caused by water sealing at the cross-over leg. (J.P.N.)

  19. W-026, transuranic waste restricted waste management (TRU RWM) glovebox operational test report

    Energy Technology Data Exchange (ETDEWEB)

    Leist, K.J.

    1998-02-18

    The TRU Waste/Restricted Waste Management (LLW/PWNP) Glovebox 401 is designed to accept and process waste from the Transuranic Process Glovebox 302. Waste is transferred to the glovebox via the Drath and Schraeder Bagless Transfer Port (DO-07401) on a transfer stand. The stand is removed with a hoist and the operator inspects the waste (with the aid of the Sampling and Treatment Director) to determine a course of action for each item. The waste is separated into compliant and non compliant. One Trip Port DO-07402A is designated as ``Compliant``and One Trip Port DO-07402B is designated as ``Non Compliant``. As the processing (inspection, bar coding, sampling and treatment) of the transferred items takes place, residue is placed in the appropriate One Trip port. The status of the waste items is tracked by the Data Management System (DMS) via the Plant Control System (PCS) barcode interface. As an item is moved for sampling or storage or it`s state altered by treatment, the Operator will track an items location using a portable barcode reader and entry any required data on the DMS console. The Operational Test Procedure (OTP) will perform evolutions (described here) using the Plant Operating Procedures (POP) in order to verify that they are sufficient and accurate for controlled glovebox operation.

  20. W-026, transuranic waste restricted waste management (TRU RWM) glovebox operational test report

    International Nuclear Information System (INIS)

    Leist, K.J.

    1998-01-01

    The TRU Waste/Restricted Waste Management (LLW/PWNP) Glovebox 401 is designed to accept and process waste from the Transuranic Process Glovebox 302. Waste is transferred to the glovebox via the Drath and Schraeder Bagless Transfer Port (DO-07401) on a transfer stand. The stand is removed with a hoist and the operator inspects the waste (with the aid of the Sampling and Treatment Director) to determine a course of action for each item. The waste is separated into compliant and non compliant. One Trip Port DO-07402A is designated as ''Compliant''and One Trip Port DO-07402B is designated as ''Non Compliant''. As the processing (inspection, bar coding, sampling and treatment) of the transferred items takes place, residue is placed in the appropriate One Trip port. The status of the waste items is tracked by the Data Management System (DMS) via the Plant Control System (PCS) barcode interface. As an item is moved for sampling or storage or it's state altered by treatment, the Operator will track an items location using a portable barcode reader and entry any required data on the DMS console. The Operational Test Procedure (OTP) will perform evolutions (described here) using the Plant Operating Procedures (POP) in order to verify that they are sufficient and accurate for controlled glovebox operation

  1. Upper extremity deep venous thrombosis after port insertion: What are the risk factors?

    Science.gov (United States)

    Tabatabaie, Omidreza; Kasumova, Gyulnara G; Kent, Tara S; Eskander, Mariam F; Fadayomi, Ayotunde B; Ng, Sing Chau; Critchlow, Jonathan F; Tawa, Nicholas E; Tseng, Jennifer F

    2017-08-01

    Totally implantable venous access devices (ports) are widely used, especially for cancer chemotherapy. Although their use has been associated with upper extremity deep venous thrombosis, the risk factors of upper extremity deep venous thrombosis in patients with a port are not studied adequately. The Healthcare Cost and Utilization Project's Florida State Ambulatory Surgery and Services Database was queried between 2007 and 2011 for patients who underwent outpatient port insertion, identified by Current Procedural Terminology code. Patients were followed in the State Ambulatory Surgery and Services Database, State Inpatient Database, and State Emergency Department Database for upper extremity deep venous thrombosis occurrence. The cohort was divided into a test cohort and a validation cohort based on the year of port placement. A multivariable logistic regression model was developed to identify risk factors for upper extremity deep venous thrombosis in patients with a port. The model then was tested on the validation cohort. Of the 51,049 patients in the derivation cohort, 926 (1.81%) developed an upper extremity deep venous thrombosis. On multivariate analysis, independently significant predictors of upper extremity deep venous thrombosis included age deep venous thrombosis (odds ratio = 1.77), all-cause 30-day revisit (odds ratio = 2.36), African American race (versus white; odds ratio = 1.86), and other nonwhite races (odds ratio = 1.35). Additionally, compared with genitourinary malignancies, patients with gastrointestinal (odds ratio = 1.55), metastatic (odds ratio = 1.76), and lung cancers (odds ratio = 1.68) had greater risks of developing an upper extremity deep venous thrombosis. This study identified major risk factors of upper extremity deep venous thrombosis. Further studies are needed to evaluate the appropriateness of thromboprophylaxis in patients at greater risk of upper extremity deep venous thrombosis. Copyright © 2017 Elsevier Inc

  2. Tests in Print II: An Index to Tests, Test Reviews, and the Literature on Specific Tests.

    Science.gov (United States)

    Buros, Oscar K., Ed.

    Tests in Print II is a comprehensive, annotated bibliography of all in-print tests published as separates for use with English-speaking subjects. The 1,155 two-column pages list 2,467 tests in print as of early 1974; 16,574 references through 1971 on specific tests; a reprinting of the 1974 APA-AERA-NCME Standards for Educational andPsychological…

  3. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Hvolby, Hans-Henrik

    2014-01-01

    While large global ports are recognised as playing a central role in many supply chains as logistic gateways, smaller regional ports have been more stagnant and have not reached the same level of development as the larger ports. The research literature in relation to port development is also...

  4. Optical aberrations in underwater photogrammetry with flat and hemispherical dome ports

    Science.gov (United States)

    Menna, Fabio; Nocerino, Erica; Remondino, Fabio

    2017-06-01

    The paper analyses differences between dome and flat port housings used for underwater photogrammetry. The underwater environment negatively affects image quality and 3D reconstructions, but this influence on photogrammetric measurements, so far, has not been addressed properly in the literature. In this work, motivations behind the need for systematic underwater calibrations are provided, then experimental tests using a specifically designed photogrammetric modular test object in laboratory and at sea are reported. The experiments are carried out using a Nikon D750 24 Mpx DSLR camera with a 24 mm f2.8 AF/D lens coupled with a NIMAR NI3D750ZM housing, equipped first with a dome and, successively, with a flat port. To quantify the degradation of image quality, MTF measurements are carried out, then the outcomes of self-calibrating bundle adjustment calibrations are shown and commented. Optical phenomena like field curvature as well as chromatic aberration and astigmatism are analysed and their implications on the degradation of image quality is factored in the bundle adjustment through a different weighting of 2D image observations.

  5. Standard test method for color and color difference of whitewares by abriged spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method describes the instrumental measurement of the reflection properties and color of ceramic glazes and other whitewares by the use of a spectrophotometer or spectrocolorimeter with a hemispherical optical measuring system, such as an integrating sphere. 1.2 The test method is suitable for use with most specimens having an exterior flat surface large enough to cover the spectrophotometer sample port. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Evaluation of MRI issues for an access port with a radiofrequency identification (RFID) tag.

    Science.gov (United States)

    Titterington, Blake; Shellock, Frank G

    2013-10-01

    A medical implant that contains metal, such as an RFID tag, must undergo proper MRI testing to ensure patient safety and to determine that the function of the RFID tag is not compromised by exposure to MRI conditions. Therefore, the objective of this investigation was to assess MRI issues for a new access port that incorporates an RFID tag. Samples of the access port with an RFID tag (Medcomp Power Injectable Port with CertainID; Medcomp, Harleysville, PA) were evaluated using standard protocols to assess magnetic field interactions (translational attraction and torque; 3-T), MRI-related heating (3-T), artifacts (3-T), and functional changes associated with different MRI conditions (nine samples, exposed to different MRI conditions at 1.5-T and 3-T). Magnetic field interactions were not substantial and will pose no hazards to patients. MRI-related heating was minimal (highest temperature change, 1.7°C; background temperature rise, 1.6°C). Artifacts were moderate in size in relation to the device. Exposures to MRI conditions at 1.5-T and 3-T did not alter or damage the functional aspects of the RFID tag. Based on the findings of the test, this new access port with an RFID tag is acceptable (or, MR conditional, using current MRI labeling terminology) for patients undergoing MRI examinations at 1.5-T/64-MHz and 3-T/128-MHz. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. JT-60 power tests from mechanical and thermal viewpoints of tokamak machine

    International Nuclear Information System (INIS)

    Takatsu, H.; Yamamoto, M.; Ohkubo, M.

    1986-01-01

    JT-60 power tests were carried out, to demonstrate, in advance of actual plasma operation, satisfactory performance of the tokamak machine, power suppliers and control system in combination. The tests began with low power ones of individual coil systems, progressed to full power ones and concluded successfully. The present paper describes the principal results of JT-60 power tests from mechanical and thermal viewpoints of tokamak machine. All of the coil systems were raised up to full power operation in combination and system performance was verified including thermal and mechanical integrity of tokamak machine. Measured strain and displacement showed good agreements with those predicted in the design, which was an evidence that electromagnetic loads were supported adequately as expected in the design. Vibration of the vacuum vessel was found to be large up to 48 m/s/sup 2/ and caused excessive vibration of the lateral port gate-valves. A few limitations to machine operation were also made clear quantatively

  8. Port of Rotterdam

    NARCIS (Netherlands)

    Veenstra, A.W.

    2014-01-01

    The port of Rotterdam is one of the largest ports in the World and has great significance for the Dutch and European economy. Newly appointed TU/e professor Albert Veenstra explains if and how the Port of Rotterdam is affected by the economic crisis. With other European ports closing in, what can

  9. Tractor accelerated test on test rig

    Directory of Open Access Journals (Sweden)

    M. Mattetti

    2013-09-01

    Full Text Available The experimental tests performed to validate a tractor prototype before its production, need a substantial financial and time commitment. The tests could be reduced using accelerated tests able to reproduce on the structural part of the tractor, the same damage produced on the tractor during real life in a reduced time. These tests were usually performed reproducing a particular harsh condition a defined number of times, as for example using a bumpy road on track to carry out the test in any weather condition. Using these procedures the loads applied on the tractor structure are different with respect to those obtained during the real use, with the risk to apply loads hard to find in reality. Recently it has been demonstrated how, using the methodologies designed for cars, it is possible to also expedite the structural tests for tractors. In particular, automotive proving grounds were recently successfully used with tractors to perform accelerated structural tests able to reproduce the real use of the machine with an acceleration factor higher than that obtained with the traditional methods. However, the acceleration factor obtained with a tractor on proving grounds is in any case reduced due to the reduced speed of the tractors with respect to cars. In this context, the goal of the paper is to show the development of a methodology to perform an accelerated structural test on a medium power tractor using a 4 post test rig. In particular, several proving ground testing conditions have been performed to measure the loads on the tractor. The loads obtained were then edited to remove the not damaging portion of signals, and finally the loads obtained were reproduced in a 4 post test rig. The methodology proposed could be a valid alternative to the use of a proving ground to reproduce accelerated structural tests on tractors.

  10. Formal Functional Test Designs: Bridging the Gap Between Test Requirements and Test Specifications

    Science.gov (United States)

    Hops, Jonathan

    1993-01-01

    This presentation describes the testing life cycle, the purpose of the test design phase, and test design methods and gives an example application. Also included is a description of Test Representation Language (TRL), a summary of the language, and an example of an application of TRL. A sample test requirement and sample test design are included.

  11. WRAP low level waste (LLW) glovebox operational test report

    Energy Technology Data Exchange (ETDEWEB)

    Kersten, J.K.

    1998-02-19

    The Low Level Waste (LLW) Process Gloveboxes are designed to: receive a 55 gallon drum in an 85 gallon overpack in the Entry glovebox (GBIOI); and open and sort the waste from the 55 gallon drum, place the waste back into drum and relid in the Sorting glovebox (GB 102). In addition, waste which requires further examination is transferred to the LLW RWM Glovebox via the Drath and Schraeder Bagiess Transfer Port (DO-07-201) or sent to the Sample Transfer Port (STC); crush the drum in the Supercompactor glovebox (GB 104); place the resulting puck (along with other pucks) into another 85 gallon overpack in the Exit glovebox (GB 105). The status of the waste items is tracked by the Data Management System (DMS) via the Plant Control System (PCS) barcode interface. As an item is moved from the entry glovebox to the exit glovebox, the Operator will track an items location using a barcode reader and enter any required data on the DMS console. The Operational Test Procedure (OTP) will perform evolution`s (described below) using the Plant Operating Procedures (POP) in order to verify that they are sufficient and accurate for controlled glovebox operation.

  12. WRAP low level waste (LLW) glovebox operational test report

    International Nuclear Information System (INIS)

    Kersten, J.K.

    1998-01-01

    The Low Level Waste (LLW) Process Gloveboxes are designed to: receive a 55 gallon drum in an 85 gallon overpack in the Entry glovebox (GBIOI); and open and sort the waste from the 55 gallon drum, place the waste back into drum and relid in the Sorting glovebox (GB 102). In addition, waste which requires further examination is transferred to the LLW RWM Glovebox via the Drath and Schraeder Bagiess Transfer Port (DO-07-201) or sent to the Sample Transfer Port (STC); crush the drum in the Supercompactor glovebox (GB 104); place the resulting puck (along with other pucks) into another 85 gallon overpack in the Exit glovebox (GB 105). The status of the waste items is tracked by the Data Management System (DMS) via the Plant Control System (PCS) barcode interface. As an item is moved from the entry glovebox to the exit glovebox, the Operator will track an items location using a barcode reader and enter any required data on the DMS console. The Operational Test Procedure (OTP) will perform evolution's (described below) using the Plant Operating Procedures (POP) in order to verify that they are sufficient and accurate for controlled glovebox operation

  13. CANFLEX fuel bundle strength tests (test report)

    International Nuclear Information System (INIS)

    Chang, Seok Kyu; Chung, C. H.; Kim, B. D.

    1997-08-01

    This document outlines the test results for the strength tests of the CANFLEX fuel bundle. Strength tests are performed to determine and verify the amount of the bundle shape distortion which is against the side-stops when the bundles are refuelling. There are two cases of strength test; one is the double side-stop test which simulates the normal bundle refuelling and the other is the single side-stop test which simulates the abnormal refuelling. the strength test specification requires that the fuel bundle against the side-stop(s) simulators for this test were fabricated and the flow rates were controlled to provide the required conservative hydraulic forces. The test rig conditions of 120 deg C, 11.2 MPa were retained for 15 minutes after the flow rate was controlled during the test in two cases, respectively. The bundle loading angles of number 13- number 15 among the 15 bundles were 67.5 deg CCW and others were loaded randomly. After the tests, the bundle shapes against the side-stops were measured and inspected carefully. The important test procedures and measurements were discussed as follows. (author). 5 refs., 22 tabs., 5 figs

  14. [Analysis for serological diagnostic results of syphilis among entry personnel in Beijing port during 2012-2014].

    Science.gov (United States)

    Feng, M X; Sun, F J; Wang, F; Wang, K L; Liu, M

    2016-06-18

    To analyze the results of syphilis specific serological tests among entry personnel in Beijing port during year 2012-2014 in order to provide evidence for the prevention and control of syphilis. Demographics data and syphilis specific test results of entry personnel were obtained from the information system of Beijing International Travel Healthcare Center and input into Excel 2016. Database for entry personnel was built up accordingly and was analyzed by IBM SPSS22.0. The number of entry personnel in Beijing port during year 2012-2014 was 106 302 person-time. According to the evaluation criteria, 71 308 persons were recruited and analyzed, of whom 277 were tested serologically positive and the total prevalence was 0.39% (95% CI: 0.34%-0.43%). The prevalence was highest in the persons aged 40-49 years (0.81%) and was higher in males (0.50%) than in females (0.23%). The persons from Africa held higher prevalence (1.27%) than from other five regions. As multivariate logical regression analysis indicated that the risk of syphilis infection was 10.38 times more in the persons aged 40-49 years than in the persons 0.05). Twenty-seven seropositive cases were found within 6 246 entry persons who were tested repeatedly during the research period, 9 of which were seroconversion cases so that the cumulative conversion rate was 0.14% (9/6 228). The average conversion time was (6.3±3.0) months. There was no statistical significance between the cumulative seroconversion rates of the persons with different genders and nationalities (P of Fisher's exact test>0.05). Serological detection of syphilis for entry personnel in Beijing port and syphilis-related health education should be reinforced to reduce the risk of disease importing and spreading, protect susceptible subjects and promote health.

  15. Mechanical and thermal characteristics of JT-60 tokamak machine demonstrated in its power tests

    International Nuclear Information System (INIS)

    Takatsu, Hideyuki; Yamamoto, Masahiro; Ohkubo, Minoru

    1985-09-01

    JT-60 power tests were carried out from Dec. 10, 1984 to Feb. 20, 1985 to demonstrate, in advance of actual plasma operation, satisfactory performance of tokamak machine, power suppliers and control system in combination. The tests began with low power test of individual coil systems and progressed to full power tests. Power tests were successfully concluded with the following conclusions. (1) All of the coil systems were raised up to full power operation in combination and system performance was verified including thermal and structural integrity of tokamak machine. (2) Measured strain and deflection showed good agreements with those predicted in the design, which was an evidence that electromagnetic loads were supported adequately as expected in the design. (3) Vibration of lateral port was found to be large up to 50 m/s 2 and caused excessive vibration of gate-valves. (4) A few limitations to machine operation were made clear quantatively. (5) It was found that the existing detectors were insufficient to monitor the machine integrity and a few kinds of detectors were necessary to be installed. (author)

  16. Design Driven Testing Test Smarter, Not Harder

    CERN Document Server

    Stephens, M

    2010-01-01

    The groundbreaking book Design Driven Testing brings sanity back to the software development process by flipping around the concept of Test Driven Development (TDD) - restoring the concept of using testing to verify a design instead of pretending that unit tests are a replacement for design. Anyone who feels that TDD is "Too Damn Difficult" will appreciate this book. Design Driven Testing shows that, by combining a forward-thinking development process with cutting-edge automation, testing can be a finely targeted, business-driven, rewarding effort. In other words, you'll learn how to test

  17. Reusable single-port access device shortens operative time and reduces operative costs.

    Science.gov (United States)

    Shussman, Noam; Kedar, Asaf; Elazary, Ram; Abu Gazala, Mahmoud; Rivkind, Avraham I; Mintz, Yoav

    2014-06-01

    In recent years, single-port laparoscopy (SPL) has become an attractive approach for performing surgical procedures. The pitfalls of this approach are technical and financial. Financial concerns are due to the increased cost of dedicated devices and prolonged operating room time. Our aim was to calculate the cost of SPL using a reusable port and instruments in order to evaluate the cost difference between this approach to SPL using the available disposable ports and standard laparoscopy. We performed 22 laparoscopic procedures via the SPL approach using a reusable single-port access system and reusable laparoscopic instruments. These included 17 cholecystectomies and five other procedures. Operative time, postoperative length of stay (LOS) and complications were prospectively recorded and were compared with similar data from our SPL database. Student's t test was used for statistical analysis. SPL was successfully performed in all cases. Mean operative time for cholecystectomy was 72 min (range 40-116). Postoperative LOS was not changed from our standard protocols and was 1.1 days for cholecystectomy. The postoperative course was within normal limits for all patients and perioperative morbidity was recorded. Both operative time and length of hospital stay were shorter for the 17 patients who underwent cholecystectomy using a reusable port than for the matched previous 17 SPL cholecystectomies we performed (p cost difference. Operating with a reusable port ended up with an average cost savings of US$388 compared with using disposable ports, and US$240 compared with standard laparoscopy. Single-port laparoscopic surgery is a technically challenging and expensive surgical approach. Financial concerns among others have been advocated against this approach; however, we demonstrate herein that using a reusable port and instruments reduces operative time and overall operative costs, even beyond the cost of standard laparoscopy.

  18. Engineering issues on the diagnostic port integration in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sunil, E-mail: paksunil@nfri.re.kr [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Bertalot, Luciano [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Cheon, Mun Seong [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Giacomin, Thibaud [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Heemskerk, Cock J.M.; Koning, Jarich F. [Heemskerk Innovative Technology, Merelhof 2, 2172 HZ Sassenheim (Netherlands); Lee, Hyeon Gon [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Nemtcev, Grigorii [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation); Ronden, Dennis M.S. [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Seon, Chang Rae [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Udintsev, Victor; Yukhnov, Nikolay [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Zvonkov, Alexander [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation)

    2016-11-01

    Highlights: • Diagnostic port integration in the upper port 18 of ITER is presented in order to house the three diagnostic systems. • Issue on the neutron shielding in the upper port 18 is addressed and the shut-down dose rate in the interspace is summarized. • The maintenance strategy in the upper port 18 is described. - Abstract: The upper port #18 (UP18) in ITER hosts three diagnostic systems: the neutron activation system, the Vacuum Ultra-Violet spectrometer system, and the vertical neutron camera. These diagnostics are integrated into three infrastructures in the port: the upper port plug, interspace support structure and port cell support structure. The port integration in UP18 is at the preliminary design stage and the current design of the infrastructure as well as the diagnostic integration is described here. The engineering issues related to neutron shielding and maintenance are addressed and the design approach is suggested.

  19. UHV testing of upgraded vacuum chambers for Indus-1

    International Nuclear Information System (INIS)

    Sindal, B.K.; Kumar, K.V.A.N.P.S.; Ramshiroman; Bhange, Nilesh; Yadav, D.P.; Sridhar, R.; Shukla, S.K.

    2013-01-01

    Indus-1 is a 450 MeV, 100 mA dedicated electron storage ring operating at pressure 10 -10 mbar range without beam and 10 -9 mbar range with beam using triode sputter ion pump (SIP) and titanium sublimation pump (TSP) combination. Indus-1 storage ring is presently working with six operational beam lines installed at three bending magnets. To accommodate two more beam lines and to reduce number of demountable joints, up-gradation of Indus-1 UHV system was planned. Salient features of upgraded vacuum system are bending magnet vacuum chambers with one extra port for additional beam line and straight section vacuum chambers with integrated TSP body. Half of the Indus-1 storage ring vacuum envelope with two bending magnet vacuum chamber and six straight section vacuum chambers were assembled with pumps, gauges etc, leak tested and tested for its UHV performance. Ultimate vacuum 5x10 -10 mbar with SIP and 2x10 -10 mbar after TSP pumping were achieved. Residual gas analyser (RGA) spectrum recorded for residual gas analysis indicated the imprints of a typical all metal UHV system having H 2 as major gas. This paper describes UHV testing of upgraded, newly fabricated vacuum chambers for Indus-1 storage ring. (author)

  20. Test design requirements: Canister-scale heater test

    International Nuclear Information System (INIS)

    Schauer, M.I.; Craig, P.A.; Stickney, R.G.

    1986-03-01

    This document establishes the Test Design Requirements for the design of a canister scale heater test to be performed in the Exploratory Shaft test facility. The purpose of the test is to obtain thermomechanical rock mass response data for use in validation of the numerical models. The canister scale heater test is a full scale simulation of a high-level nuclear waste container in a prototypic emplacement borehole. Electric heaters are used to simulate the heat loads expected in an actual waste container. This document presents an overview of the test including objectives and justification for the test. A description of the test as it is presently envisioned is included. Discussions on Quality Assurance and Safety are also included in the document. 12 refs., 1 fig

  1. Desert Rats 2010 Operations Tests: Insights from the Geology Crew Members

    Science.gov (United States)

    Bleacher, J. E.; Hurtado, J. M., Jr.; Young, K. E.; Rice, J.; Garry, W. B.; Eppler, D.

    2011-01-01

    Desert Research and Technology Studies (Desert RATS) is a multi-year series of tests of NASA hardware and operations deployed in the high desert of Arizona. Conducted annually since 1997, these activities exercise planetary surface hardware and operations in relatively harsh conditions where long-distance, multi-day roving is achievable. Such activities not only test vehicle subsystems, they also stress communications and operations systems and enable testing of science operations approaches that advance human and robotic surface exploration capabilities. Desert RATS 2010 tested two crewed rovers designed as first-generation prototypes of small pressurized vehicles, consistent with exploration architecture designs. Each rover provided the internal volume necessary for crewmembers to live and work for periods up to 14 days, as well as allowing for extravehicular activities (EVAs) through the use of rear-mounted suit ports. The 2010 test was designed to simulate geologic science traverses over a 14-day period through a volcanic field that is analogous to volcanic terrains observed throughout the Solar System. The test was conducted between 31 August and 13 September 2010. Two crewmembers lived in and operated each rover for a week with a "shift change" on day 7, resulting in a total of eight test subjects for the two-week period. Each crew consisted of an engineer/commander and an experienced field geologist. Three of the engineer/commanders were experienced astronauts with at least one Space Shuttle flight. The field geologists were drawn from the scientific community, based on funded and published field expertise.

  2. Physical Modelling of Geotechnical Structures in Ports and Offshore

    Directory of Open Access Journals (Sweden)

    Bałachowski Lech

    2017-04-01

    Full Text Available The physical modelling of subsoil behaviour and soil-structure interaction is essential for the proper design of offshore structures and port infrastructure. A brief introduction to such modelling of geoengineering problems is presented and some methods and experimental devices are described. The relationships between modelling scales are given. Some examples of penetration testing results in centrifuge and calibration chamber are presented. Prospects for physical modelling in geotechnics are also described.

  3. Environmental risk assessment of water quality in harbor areas: a new methodology applied to European ports.

    Science.gov (United States)

    Gómez, Aina G; Ondiviela, Bárbara; Puente, Araceli; Juanes, José A

    2015-05-15

    This work presents a standard and unified procedure for assessment of environmental risks at the contaminant source level in port aquatic systems. Using this method, port managers and local authorities will be able to hierarchically classify environmental hazards and proceed with the most suitable management actions. This procedure combines rigorously selected parameters and indicators to estimate the environmental risk of each contaminant source based on its probability, consequences and vulnerability. The spatio-temporal variability of multiple stressors (agents) and receptors (endpoints) is taken into account to provide accurate estimations for application of precisely defined measures. The developed methodology is tested on a wide range of different scenarios via application in six European ports. The validation process confirms its usefulness, versatility and adaptability as a management tool for port water quality in Europe and worldwide. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Remote Handling behind port plug in ITER

    International Nuclear Information System (INIS)

    Bede, O.; Neuberger, H.

    2006-01-01

    Different Test Blanket Modules (TBM) will be used in succession in the same equatorial ports of ITER. The remote handling operations for connection/disconnection of an interface between the port plug of the EU-HCPB-TBM and the port cell equipment are investigated with the goal to reach a quick and simple TBM exchange procedure. This paper describes the operations and systems which are required for connection of the TBM to its supply lines at this interface. The interface is located inside the free space of the port plug flange between the port plug shield and the bioshield of the port cell behind. The approach of the operation place is only available through a narrow gate in the bioshield opened temporarily during maintenance periods. This gate limits the dimensions of the whole system and its tools. The current design of the EU-HCPB-TBM foresees up to 9 supply lines which have to be connected inside the free space of one half of the port plug flange. The connection operations require positioning and adjustment of the tools for each pipe separately. Despite the strict circumstances it is still possible to find such an industrial jointed-arm robot with sufficient payload, which can penetrate into the working area. A mechanical system is necessary to move the robot from its storing place in the hot cell to the port plug on 6 m distance. Each operation requires different end-of-arm tools. The most special one is a pipe positioner tool, which can position and pull the pipe ends to each other and align the tool before welding and hold them in proper position during the welding process. Weld seams can be made by orbital welding tool. The pipe positioner tool has to provide place for welding tool. Using of inbore tool is impossible because pipes have no open ends where the tool could leave it. Orbital tool must be modified to meet requirements of remote handling because it is designed for human handling. The coolant is helium, so for eliminating the leak of helium it is

  5. Testing on air cleaning systems: Testing of the components in-place tests

    International Nuclear Information System (INIS)

    Billard, F.; Brion, J.

    1967-01-01

    The reliability of air cleaning systems is dependent on testing they are submitted to. Although in-place tests are the most important as they act as final tests upon achieved plants, component tests are necessary too. They allow detection of defective units before they are installed, partition of unit defects from mounting defects and they are more sensitive. For similar reasons, material teats are most useful. The various tests are described, about aerosol filters for one part, iodine trap for the other. The checked features are: materials nature, units sizes, efficiency, air resistance, flammability, humidity resistance, temperature resistance, adsorbent friability, etc... On iodine trapping systems, small check traps, working by-pass with the main trap are periodically subjected to efficiency test. This control allow to cut down the in-place tests frequency, particularly when poisoning from organic vapours is to be feared. (authors) [fr

  6. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  7. Development and performance test of small angle neutron spectrometer at HANARO

    International Nuclear Information System (INIS)

    Han, Young Soo; Seong, Baek Seok; Lee, Chang Hee; Lee, Jeong Soo; Hong, Kwang Pyo; Choi, Byung Hoon; Choi, Young Hyun; Shin, Eun Joo; Park, Kook Nam

    2004-12-01

    The construction of Small Angle Neutron Spectrometer(SANS) at the CN beam port in HANARO was completed and has been opened to users in July 2001. the 2-D PSD (two dimensional position sensitive detector), the NVS (neutron velocity selector), the detector chamber rotation system, the detector horizontal moving system, the stepping motors, the beam shutter and the attenuator were fully tested and installed. The performance test of all the components was also completed. Wavelengths and resolutions of the neutron beam monochromatized by the NVS were calibrated using both the time-of-flight method and the diffraction measurement on standard material, the silver behenate. The relationship between the selector speed U[rpm] and the neutron wavelength λ[A] was obtained as λ[A]=0.11077+107171/U[rpm]. The controllers for the sample environments, the beam shutter and the stepping motors were constructed and its control programs for those controllers were also developed. The Beam test for the SANS has been finished and the characteristics of neutron beam was analyzed. The experimental methods of SANS and its data treatment method were established. The performance test of the HANARO SANS compared with that of foreign SANS's. shows that the HANARO SANS is quite well comparable with foreign SANS facilities

  8. Irradiation effects test Series Scoping Test 1: test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.

    1977-09-01

    The report describes the results of the first scoping test in the Irradiation Effects Test Series conducted by the Thermal Fuels Behavior Program, which is part of the Water Reactor Research Program of EG and G Idaho, Inc. The research is sponsored by the United States Nuclear Regulatory Commission. This test used an unirradiated, three-foot-long, PWR-type fuel rod. The objective of this test was to thoroughly evaluate the remote fabrication procedures to be used for irradiated rods in future tests, handling plans, and reactor operations. Additionally, selected fuel behavior data were obtained. The fuel rod was subjected to a series of preconditioning power cycles followed by a power increase which brought the fuel rod power to about 20.4 kW/ft peak linear heat rating at a coolant mass flux of 1.83 x 10 6 lb/hr-ft 2 . Film boiling occurred for a period of 4.8 minutes following flow reductions to 9.6 x 10 5 and 7.5 x 10 5 lb/hr-ft 2 . The test fuel rod failed following reactor shutdown as a result of heavy internal and external cladding oxidation and embrittlement which occurred during the film boiling operation

  9. The Re-Conceptualization of the Port Supply Chain as a Smart Port Service System: The Case of the Port of Salerno

    Directory of Open Access Journals (Sweden)

    Antonio Botti

    2017-04-01

    Full Text Available This paper proposes a re-conceptualization of the port supply chain as a smart service system, in accordance with the theory of service science. Starting from a short literature review about the port supply chain approach and service science, a new comprehensive framework is provided to better understand seaport dynamics and the creation of competitive port supply chains. The methodology used is the case study approach. The Authors examined the Port of Salerno (Italy and re-conceptualized it as a smart port service system. The originality of the work lies in the application of service science as a lens to re-conceptualize the port supply chain, that allows the implementation of a logistic framework. Both theoretical and practical implications are provided to enrich the literature about port supply chains and to support port operators.

  10. Testes de função pulmonar no transplante de medula óssea: Revisão sistemática

    Directory of Open Access Journals (Sweden)

    Eliane Viana Mancuso

    2006-01-01

    Full Text Available Resumo: As complicações pulmonares constituem causa importante de morbidade e mortalidade em doentes submetidos a transplante de medula óssea. Os testes de função pulmonar são utilizados rotineiramente na avaliação antes e no acompanhamento após o transplante. A revisão sistemática da literatura mostrou que a presença de alterações nos testes de função pulmonar antes do transplante de medula não esteve relacionada com maior incidência de complicações pulmonares pós-transplante. Entretanto, alterações destes testes após o transplante estiveram relacionadas com maior incidência de complicações respiratórias. Desta forma, embora as alterações dos testes de função pulmonar pré-transplante não tenham sido de valor preditivo positivo na detecção precoce de complicações respiratórias pós-transplante, os mesmos podem ser úteis na comparação com os testes realizados após o transplante e devem fazer parte da avaliação de doentes candidatos ao transplante de medula óssea.Rev Port Pneumol 2006; XII (1: 61-69 Abstract: The pulmonary function test plays an important role in the management of pulmonary complications after bone marrow transplantation. Although its utility in helping to predict the likelihood of developing post transplant pulmonary complications and mortality is not well established, current data indicate that pre-transplant pulmonary function tests are important as a reference for the interpretation of post transplant pulmonary function tests and for identifying patients at high risk of developing pulmonary complications and/or mortality after bone marrow transplantation.Rev Port Pneumol 2006; XII (1: 61-69 Palavras-chave: Transplante de medula óssea, testes de função pulmonar, revisão sistemática, Key-words: Bone marrow transplantation, respiratory function tests, systematic review

  11. Testing Significance Testing

    Directory of Open Access Journals (Sweden)

    Joachim I. Krueger

    2018-04-01

    Full Text Available The practice of Significance Testing (ST remains widespread in psychological science despite continual criticism of its flaws and abuses. Using simulation experiments, we address four concerns about ST and for two of these we compare ST’s performance with prominent alternatives. We find the following: First, the 'p' values delivered by ST predict the posterior probability of the tested hypothesis well under many research conditions. Second, low 'p' values support inductive inferences because they are most likely to occur when the tested hypothesis is false. Third, 'p' values track likelihood ratios without raising the uncertainties of relative inference. Fourth, 'p' values predict the replicability of research findings better than confidence intervals do. Given these results, we conclude that 'p' values may be used judiciously as a heuristic tool for inductive inference. Yet, 'p' values cannot bear the full burden of inference. We encourage researchers to be flexible in their selection and use of statistical methods.

  12. Test report - caustic addition system operability test procedure

    International Nuclear Information System (INIS)

    Parazin, R.E.

    1995-01-01

    This Operability Test Report documents the test results of test procedure WHC-SD-WM-OTP-167 ''Caustic Addition System Operability Test Procedure''. The Objective of the test was to verify the operability of the 241-AN-107 Caustic Addition System. The objective of the test was met

  13. DATE V1 - Data Aquisition Test Environment Users Manual

    CERN Document Server

    Grandegger, W; CERN. Geneva

    1996-01-01

    The Data Aquisition presented here has been developed for maximum portability and generality. If you are lucky you will have tailored the system to your experimental set-up in less than a day and start taking data. It should run any UNIX system and some non-UNIX system and has already been tested on the following systems: Linux (IBM PC and compatible) OSF (Alpha workstations and Medulla VME board) HP-UX (workstation + 743 VME board) HP-RT AIX OS91) LynxOS (tested on a 68040 and a PowerPC) 1) The system was originally developed under UNIX. Only due to popular request of people who wanted to reuse old hardware it was ported to OS9. This is, however, not the recommended hardware and future improvements of the system are not going to be refitted to OS9. Currently we distribute only the OS9 and HP-UX binary versions, but you get the code and can compile it on any of the above systems and with some luck on others.

  14. Test Architecture, Test Retrofit

    Science.gov (United States)

    Fulcher, Glenn; Davidson, Fred

    2009-01-01

    Just like buildings, tests are designed and built for specific purposes, people, and uses. However, both buildings and tests grow and change over time as the needs of their users change. Sometimes, they are also both used for purposes other than those intended in the original designs. This paper explores architecture as a metaphor for language…

  15. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  16. [Use of percutaneous needles in the feasability of single-port laparoscopic cholecystectomy].

    Science.gov (United States)

    Dávila, Fausto; Tsin, Daniel; González, Gloria; Dávila, M Ruth; Lemus, José; Dávila, Ulises

    2014-04-01

    The usefulness of percutaneous needles (PN) to replace traditional assistance ports in mini-invasive techniques with a single port is analyzed and their feasibility for conducting a single port laparoscopic cholecystectomy (SPLC) is demonstrated. A retrospective, linear and descriptive study covering 2,431 patients with a diagnosis of acute and non-acute gallbladder disease has been conducted. The patients underwent a single port laparoscopic cholecystectomy using some type of PNs, replacing the assisting ports used in traditional laparoscopic cholecystechtomy (TLC). Based on the progressive use of PNs-reins (R), hooked needles (HN) and passing suture needles (PSN)-to carry out the SPLC technique, 3 groups have been established: A, B and C. The results were compared using a Student T test, odds ratio and CI and were analyzed by means of the SPSS software v. 13.0. The use of PNs showed an increased feasibility for the laparoscopic procedure, as they were included in the surgical technique. The R were useful when carrying out the SPLC in 78% of the cases and when the HK were added, the results increased to 88%. When using the 3 types (R, HN and PSN), the results increased by 96%. Statistical significance was obtained with these values: chi 2=67.13 and P<.001; odds ratio and 95% CI became significant when comparing the B/C, A/C, and A-B/C groups. The PNs, replacing the assisting ports in laparoscopy, make it possible to attain a feasibility of the process in 96% of the cases. This percentage was similar to what is achieved with the TLC, which places the one port laparoscopy surgery technique as an advantageous and economic alternative. This application of the PNs could be made extensive to other single-port techniques, with a multi-valve platform and natural orifice surgery. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  17. Permeation Dispersal of Treatment Agents for In Situ Remediation in Low Permeability Media: 1. Field Studies in Unconfined Test Cells

    International Nuclear Information System (INIS)

    Siegrist, R.L.; Smuin, D.R.; Korte, N.E.; Greene, D.W.; Pickering, D.A.; Lowe, K.S.; Strong-Gunderson, J.

    2000-01-01

    Chlorocarbons like trichloroethylene (TCE) are common contaminants of concern at US Department of Energy (DOE) facilities and industrial sites across the US and abroad. These contaminants of concern are present in source areas and in soil and ground water plumes as dissolved or sorbed phase constituents as well as dense nonaqueous-phase liquids (DNAPLs). These DNAPL compounds can be released to the environment through a variety of means including leaks in storage tanks and transfer lines, spills during transportation, and land treatment of wastes. When DNAPL compounds are present in low permeability media (LPM) like silt and clay layers or deposits, there are major challenges with assessment of their behavior and implementation of effective in situ remediation technologies. This report describes a field demonstration that was conducted at the Portsmouth Gaseous Diffusion Plant (PORTS) Clean Test Site (CTS) to evaluate the feasibility of permeation and dispersal of reagents into LPM. Various reagents and tracers were injected at seven test cells primarily to evaluate the feasibility of delivery, but also to evaluate the effects of the injected reagents on LPM. The various reagents and tracers were injected at the PORTS CTS using a multi-port injection system (MPIS) developed and provided by Hayward Baker Environmental, Inc

  18. Energy Systems Test Area (ESTA) Electrical Power Systems Test Operations: User Test Planning Guide

    Science.gov (United States)

    Salinas, Michael J.

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTA Electrical Power Systems Test Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  19. FEM analyses and prototype tests of the UPP structure for the ECRH in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, D. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Materials Research I, P.O. Box 3640, D-76021 Karlsruhe (Germany)], E-mail: dirk.strauss@imf.fzk.de; Gantenbein, G. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Pulsed Power and Microwave Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Heidinger, R.; Kleefeldt, K. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Materials Research I, P.O. Box 3640, D-76021 Karlsruhe (Germany); Leonhardt, W. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Pulsed Power and Microwave Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Meier, A. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Materials Research I, P.O. Box 3640, D-76021 Karlsruhe (Germany); Mellein, D. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Pulsed Power and Microwave Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Scherer, T. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Materials Research I, P.O. Box 3640, D-76021 Karlsruhe (Germany); Serikov, A. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Reactor Safety, P.O. Box 3640, D-76021 Karlsruhe (Germany); Spaeh, P.; Vaccaro, A. [Forschungszentrum Karlsruhe, Association FZK-Euratom, Karlsruhe (Germany); Institute for Materials Research I, P.O. Box 3640, D-76021 Karlsruhe (Germany)

    2009-06-15

    The ITER electron cyclotron upper port launching system has to provide local current drive in order to stabilize neoclassical tearing modes (NTMs) and the sawtooth instability. The mm-wave system is embedded in a rigid upper port plug structure optimized for the rough operating conditions. During regular operation the structure is heated by neutrons and photons which are simulated by the Monte-Carlo method. The structural system has to provide sufficient cooling especially in the front part where high heat loads occur. If the active plasma stabilization fails the worst case scenario for the upper port plugs is the upward vertical displacement event (VDE) followed by a fast current quench. The fast plasma disruption occurs close to the plugs; eddy currents are induced and interact with the strong static magnetic field. The resulting mechanical forces and torque moments stress the structural system to its physical limits; a detailed numerical analysis, prototype crosschecks and design optimization is required to obtain a working system for ITER. Numerical structural, thermal and fluid dynamic analyses are presented as well as prototype tests and finally the effect of plasma disruptions on the structural design is discussed.

  20. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-01-01

    and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot

  1. Digface characterization test plan (remote testing)

    International Nuclear Information System (INIS)

    Croft, K.; Hyde, R.; Allen, S.

    1993-08-01

    The objective of the Digface Characterization (DFC) Remote Testing project is to remotely deploy a sensor head (Mini-Lab) across a digface to determine if it can characterize the contents below the surface. The purpose of this project is to provide a robotics technology that allows removal of workers from hazards, increases speed of operations, and reduces life cycle costs compared to alternate methods and technologies. The Buried Waste Integrated Demonstration (BWID) is funding the demonstration, testing, and evaluation of DFC. This document describes the test plan for the DFC remote deployment demonstration for the BWID. The purposes of the test plan are to establish test parameters so that the demonstration results are deemed useful and usable and perform the demonstration in a safe manner and within all regulatory requirements

  2. Sea freight - Antwerp Port

    Directory of Open Access Journals (Sweden)

    NEACSU Nicoleta Andreea

    2017-01-01

    Full Text Available Shipping plays a vital role in achieving the movement of goods, both in terms of quantity and efficiency. This paper presents the role and advantages of shipping in the global economy and analyzes the development and Antwerp Port activity. Currently, the second most important trading port in Europe and 14th in the ranking of most important ports that handle containers worldwide, the Port of Antwerp, Belgium is a port in the heart of Europe, accessible to large sized vessels. 200 years of constructing infrastructure and logistics around the central location, as well as pressure from Rotterdam, that had an impact on the competitiveness of the port of Antwerp, all this led the port to occupy a leading position in the top rankings.

  3. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  4. Determinants of Port Performance - Case Study of 4 Main Ports in Indonesia (2005-2015

    Directory of Open Access Journals (Sweden)

    Atika Aqmarina

    2018-03-01

    Full Text Available Port plays significant role in supporting economic growth of a country. This study aims to analyze the determinant of port performance in Indonesia. In this research, the ports selected are four main ports in Indonesia which are Port of Belawan, Port of Tanjung Priok, Port of Tanjung Perak, and Makassar. These ports are designed as the hub ports in the national sea transport system of the country. The study used pooled OLS as the methodology to analyze the determinant. The result of this studies shows that total traffic is not influenced by operating surplus per ton, whereas the rest of variables such as turnaround time, idle time, berth of occupancy rate, rate of return, number of employee and cargo equipment have significant results and significantly influenced the total traffic.

  5. Endurance test of DUPIC irradiation test rig-003

    Energy Technology Data Exchange (ETDEWEB)

    Moon, J.S; Yang, M.S.; Lee, C.Y.; Ryu, J.S.; Jeon, H.G

    2001-04-01

    This report presents the pressure drop, vibration and endurance test results for DUPIC Irradiation Test Rig-003 which was design and fabricated by KAERI. From the pressure drop and vibration test results, it is verified that DUPIC Irradiation Test Rig-003 satisfied the limit conditions of HANARO. And, remarkable wear is not observed in DUPIC Irradiation Test Rig-003 during 40 endurance test days.

  6. Ultrasonic Testing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeong Jun; Kuk, Jeong Han

    2002-02-15

    This book introduces ultrasonic testing, which tells of outline of ultrasonic testing, principle of ultrasonic testing, prosperities of ultrasonic waves, radiographic test and ultrasonic test, basic theory on ultrasonic testing, mode conversion, transmission and diffraction, ultrasonic flaw detection and probe, standard test piece and reference test piece, like KS(JIS) ASME and ASTM, classification and properties of ultrasonic testing, straight beam method, angle beam method, ASME SEC.V.Art.5 ASTMA 388 and KS B 0817 Korean industrial standard.

  7. ITER lower port systems integration

    Energy Technology Data Exchange (ETDEWEB)

    Levesy, B., E-mail: bruno.levesy@iter.org [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Baker, D.; Boussier, B.; Bryan, S.; Cordier, J.J.; Dremel, M.; Dell' Orco, G.; Daly, E.; Doshi, B.; Jeannoutot, T.; Friconneau, J.P.; Gliss, C.; Le Barbier, R.; Lachevre, F.; Loughlin, M.; Martin, A.; Martins, J.P.; Maruyama, S.; Palmer, J.; Reichle, R. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2011-10-15

    The lower port systems are installed inside the vacuum vessel lower ports and in the adjacent port cells. The vacuum vessel ports and penetrations are allocated as follow: -4 ports dedicated to remote handling of the divertor cassettes, contain diagnostics racks and divertor cooling pipes. -5 ports connecting the main vessel to the torus cryopumps, contain divertor cooling pipes, pellet and gas injection pipes and vertical stabilization coil feeders. -3 penetrations connecting torus cryopumps are connected to the vacuum vessel by branch pipes. -Specific penetrations for divertor cooling lines, in-vessel viewing and glow discharge systems. The general layout of the port systems has been revised recently to improve the cryopump (8 t weight, 1.8 m diameter and 2.5 m long) maintenance scheme with remote handling tools and integrate the in-vessel vertical stabilization coil feeders. The port allocation, the pumping ports design, and interfaces in-between ports and cryostat and in-between cryopumps and cryostat have been up-dated. The integration inside the 18 port cells (11 m x 4 m each) has been reviewed to avoid clashes in between systems and to fix the openings in the port cell concrete walls. The new layout integrates safety and neutron-shielding requirements as well as remote handling and maintenance compatibility for the different systems. The paper presents the up-dated integration of the lower port systems inside the ports and the port cells. Interfaces of the port systems with the vacuum vessel, the cryostat and the port cells are described.

  8. Extended shadow test approach for constrained adaptive testing

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; Ariel, A.

    2002-01-01

    Several methods have been developed for use on constrained adaptive testing. Item pool partitioning, multistage testing, and testlet-based adaptive testing are methods that perform well for specific cases of adaptive testing. The weighted deviation model and the Shadow Test approach can be more

  9. From Test Takers to Test Makers

    Science.gov (United States)

    Smith, Kari

    2009-01-01

    As a classroom teacher, Kari Smith realized that traditional objective tests don't always assess what students actually know. But tests are so deeply embedded in the education system that it would be difficult to do away with them entirely. Smith decided to make tests into learning tools. In this article, Smith describes three strategies for…

  10. The Design Of The Ultrasonic Nondestructive Testing System Based On The EMAT

    Directory of Open Access Journals (Sweden)

    Cheng Huan Xin

    2016-01-01

    Full Text Available This paper introduces a kind of based on the electromagnetic acoustic transducer (EMAT metal pipeline detection system, fusion of two dimensional orientation, shape unique technological innovation, implementation of various metal pipe wall corrosion situation of rapid, accurate, fully automated non-destructive testing.In the aspect of hardware design, single-chip microcomputer control was achieved by C language programming the launch of the pulse signal. Pulse signal was sent to launch circuit, ultrasonic signal. Design of preamplifier, controllable gain amplifier two-stage amplifier circuit for receiving signal is amplified. Including data acquisition circuit detection circuit and A/D conversion circuit, single chip microcomputer and the LabVIEW platform via A serial port communication agreement. In the aspect of software design, the design of the EMAT pipe nondestructive testing system based on LabVIEW human-computer interaction interface.

  11. Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis screening and treatment of pregnant women in Port-au-Prince, Haiti.

    Science.gov (United States)

    Bristow, Claire C; Mathelier, Patricia; Ocheretina, Oksana; Benoit, Daphne; Pape, Jean W; Wynn, Adriane; Klausner, Jeffrey D

    2017-10-01

    In Haiti, routine screening for Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), and Trichomonas vaginalis (TV) among pregnant women is not conducted; yet these sexually transmitted infections (STIs) are associated with adverse birth and newborn health outcomes. We aimed to assess the acceptability and feasibility of screening and the prevalence of STIs among pregnant women in Port-au-Prince, Haiti. Pregnant women of at least 18 years of age who attend Haitian Study Group for Kaposi's sarcoma and Opportunistic Infections (GHESKIO) clinics in Port-au-Prince, Haiti provided self-collected vaginal swab specimens. Laboratory testing was done with Xpert® CT/NG and Xpert® TV. The results of this study showed that of the 322 pregnant women who visited GHESKIO for their regular scheduled appointments, 300 (93.2%) consented for CT, NG, and TV testing. Of those, 107 women (35.7%) tested positive for at least one STI. There were 42 (14.7%) cases of CT, 8 (2.8%) NG, and 83 (29.0%) TV infections. Most infections were treated - 122 of 133 (91.7%). In summary, we found that it was highly acceptable and feasible to implement CT, NG, and TV screening among pregnant women in Port-au-Prince, Haiti. We found high prevalence of STIs among pregnant women, which suggest that STI screening in this population may be warranted.

  12. The LHCD Launcher for Alcator C-Mod - Design, Construction, Calibration and Testing

    International Nuclear Information System (INIS)

    Hosea, J.; Beals, D.; Beck, W.; Bernabei, S.; Burke, W.; Childs, R.; Ellis, R.; Fredd, E.; Greenough, N.; Grimes, M.; Gwinn, D.; Irby, J.; Jurczynski, S.; Koert, P.; Kung, C.C.; Loesser, G.D.; Marmar, E.; Parker, R.; Rushinski, J.; Schilling, G.; Terry, D.; Vieira, R.; Wilson, J.R.; Zaks, J.

    2005-01-01

    MIT and PPPL have joined together to fabricate a high-power lower hybrid current drive (LHCD) system for supporting steady-state AT regime research on Alcator C-Mod. The goal of the first step of this project is to provide 1.5 MW of 4.6 GHz rf [radio frequency] power to the plasma with a compact launcher which has excellent spectral selectivity and fits into a single C-Mod port. Some of the important design, construction, calibration and testing considerations for the launcher leading up to its installation on C-Mod are presented here

  13. Test design requirements: Thermal conductivity probe testing

    International Nuclear Information System (INIS)

    Heath, R.E.

    1985-01-01

    This document establishes the test design requirements for development of a thermal conductivity probe test. The thermal conductivity probe determines in situ thermal conductivity using a line source transient heat conduction analysis. This document presents the rationale for thermal conductivity measurement using a thermal conductivity probe. A general test description is included. Support requirements along with design constraints are detailed to allow simple design of the thermal conductivity probe and test. The schedule and delivery requirements of the responsible test designer are also included. 7 refs., 1 fig

  14. [A novel serial port auto trigger system for MOSFET dose acquisition].

    Science.gov (United States)

    Luo, Guangwen; Qi, Zhenyu

    2013-01-01

    To synchronize the radiation of microSelectron-HDR (Nucletron afterloading machine) and measurement of MOSFET dose system, a trigger system based on interface circuit was designed and corresponding monitor and trigger program were developed on Qt platform. This interface and control system was tested and showed stable operate and reliable work. This adopted serial port detect technique may expand to trigger application of other medical devices.

  15. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    International Nuclear Information System (INIS)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan

    2004-01-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications

  16. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan [Asan Medical Center, Seoul (Korea, Republic of)

    2004-04-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications.

  17. Principal Ports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Principal Ports are defined by port limits or US Army Corps of Engineers (USACE) projects, these exclude non-USACE projects not authorized for publication. The...

  18. The X-625 Groundwater Treatment Facility: A field-scale test of trichloroethylene dechlorination using iron filings for the X-120/X-749 groundwater plume

    International Nuclear Information System (INIS)

    Liang, L.; West, O.R.; Korte, N.E.

    1997-09-01

    The dehalogenation of chlorinated solvents by zero-valence iron has recently become the subject of intensive research and development as a potentially cost-effective, passive treatment for contaminated groundwater through reactive barriers. Because of its successful application in the laboratory and other field sites, the X-625 Groundwater Treatment Facility (GTF) was constructed to evaluate reactive barrier technology for remediating trichloroethylene (TCE)-contaminated groundwater at the Portsmouth Gaseous Diffusion Plant (PORTS). The X-625 GTF was built to fulfill the following technical objectives: (1) to test reactive barrier materials (e.g., iron filings) under realistic groundwater conditions for long term applications, (2) to obtain rates at which TCE degrades and to determine by-products for the reactive barrier materials tested, and (3) to clean up the TCE-contaminated water in the X-120 plume. The X-625 is providing important field-scale and long-term for the evaluation and design of reactive barriers at PORTS. The X-625 GTS is a unique facility not only because it is where site remediation is being performed, but it is also where research scientists and process engineers can test other promising reactive barrier materials. In addition, the data collected from X-625 GTF can be used to evaluate the technical and economic feasibility of replacing the activated carbon units in the pump-and-treat facilities at PORTS

  19. NIF ICCS Test Controller for Automated and Manual Testing

    International Nuclear Information System (INIS)

    Zielinski, J S

    2007-01-01

    The National Ignition Facility (NIF) Integrated Computer Control System (ICCS) is a large (1.5 MSLOC), hierarchical, distributed system that controls all aspects of the NIF laser [1]. The ICCS team delivers software updates to the NIF facility throughout the year to support shot operations and commissioning activities. In 2006, there were 48 releases of ICCS: 29 full releases, 19 patches. To ensure the quality of each delivery, thousands of manual and automated tests are performed using the ICCS Test Controller test infrastructure. The TestController system provides test inventory management, test planning, automated test execution and manual test logging, release testing summaries and test results search, all through a web browser interface. Automated tests include command line based frameworks server tests and Graphical User Interface (GUI) based Java tests. Manual tests are presented as a checklist-style web form to be completed by the tester. The results of all tests, automated and manual, are kept in a common repository that provides data to dynamic status reports. As part of the 3-stage ICCS release testing strategy, the TestController system helps plan, evaluate and track the readiness of each release to the NIF facility

  20. Reiter haemagglutination test: a screening test for syphilis.

    OpenAIRE

    Al-Qudah, A A; Mostratos, A

    1982-01-01

    Using an ultrasonicate of the Reiter treponeme as antigen the Reiter haemagglutination test (RHA) was evaluated as a serological test for syphilis. Comparison of the results of the cardiolipin Wassermann reaction, Reiter protein complement-fixation test, the fluorescent treponemal antibody-absorbed (FTA-ABS) test, the Treponema pallidum haemagglutination test (TPHA) (at dilutions of 1/16 and 1/80), and the Venereal Disease Research Laboratory test with those of the RHA showed that the RHA was...

  1. Manufacturing, assembly and tests of SPIDER Vacuum Vessel to develop and test a prototype of ITER neutral beam ion source

    Energy Technology Data Exchange (ETDEWEB)

    Zaccaria, Pierluigi, E-mail: pierluigi.zaccaria@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Padova (Italy); Valente, Matteo; Rigato, Wladi; Dal Bello, Samuele; Marcuzzi, Diego; Agostini, Fabio Degli; Rossetto, Federico; Tollin, Marco [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Padova (Italy); Masiello, Antonio [Fusion for Energy F4E, Barcelona (Spain); Corniani, Giorgio; Badalocchi, Matteo; Bettero, Riccardo; Rizzetto, Dario [Ettore Zanon S.p.A., Schio (VI) (Italy)

    2015-10-15

    Highlights: • The SPIDER experiment aims to qualify and optimize the ion source for ITER injectors. • The large SPIDER Vacuum Vessel was built and it is under testing at the supplier. • The main working and assembly steps for production are presented in the paper. - Abstract: The SPIDER experiment (Source for the Production of Ions of Deuterium Extracted from an RF plasma) aims to qualify and optimize the full size prototype of the negative ion source foreseen for MITICA (full size ITER injector prototype) and the ITER Heating and Current Drive Injectors. Both SPIDER and MITICA experiments are presently under construction at Consorzio RFX in Padova (I), with the financial support from IO (ITER Organization), Fusion for Energy, Italian research institutions and contributions from Japan and India Domestic Agencies. The vacuum vessel hosting the SPIDER in-vessel components (Beam Source and calorimeters) has been manufactured, assembled and tested during the last two years 2013–2014. The cylindrical vessel, about 6 m long and 4 m in diameter, is composed of two cylindrical modules and two torispherical lids at the ends. All the parts are made by AISI 304 L stainless steel. The possibility of opening/closing the vessel for monitoring, maintenance or modifications of internal components is guaranteed by bolted junctions and suitable movable support structures running on rails fixed to the building floor. A large number of ports, about one hundred, are present on the vessel walls for diagnostic and service purposes. The main working steps for construction and specific technological issues encountered and solved for production are presented in the paper. Assembly sequences and tests on site are furthermore described in detail, highlighting all the criteria and requirements for correct positioning and testing of performances.

  2. Manufacturing, assembly and tests of SPIDER Vacuum Vessel to develop and test a prototype of ITER neutral beam ion source

    International Nuclear Information System (INIS)

    Zaccaria, Pierluigi; Valente, Matteo; Rigato, Wladi; Dal Bello, Samuele; Marcuzzi, Diego; Agostini, Fabio Degli; Rossetto, Federico; Tollin, Marco; Masiello, Antonio; Corniani, Giorgio; Badalocchi, Matteo; Bettero, Riccardo; Rizzetto, Dario

    2015-01-01

    Highlights: • The SPIDER experiment aims to qualify and optimize the ion source for ITER injectors. • The large SPIDER Vacuum Vessel was built and it is under testing at the supplier. • The main working and assembly steps for production are presented in the paper. - Abstract: The SPIDER experiment (Source for the Production of Ions of Deuterium Extracted from an RF plasma) aims to qualify and optimize the full size prototype of the negative ion source foreseen for MITICA (full size ITER injector prototype) and the ITER Heating and Current Drive Injectors. Both SPIDER and MITICA experiments are presently under construction at Consorzio RFX in Padova (I), with the financial support from IO (ITER Organization), Fusion for Energy, Italian research institutions and contributions from Japan and India Domestic Agencies. The vacuum vessel hosting the SPIDER in-vessel components (Beam Source and calorimeters) has been manufactured, assembled and tested during the last two years 2013–2014. The cylindrical vessel, about 6 m long and 4 m in diameter, is composed of two cylindrical modules and two torispherical lids at the ends. All the parts are made by AISI 304 L stainless steel. The possibility of opening/closing the vessel for monitoring, maintenance or modifications of internal components is guaranteed by bolted junctions and suitable movable support structures running on rails fixed to the building floor. A large number of ports, about one hundred, are present on the vessel walls for diagnostic and service purposes. The main working steps for construction and specific technological issues encountered and solved for production are presented in the paper. Assembly sequences and tests on site are furthermore described in detail, highlighting all the criteria and requirements for correct positioning and testing of performances.

  3. 40 CFR 53.65 - Test procedure: Loading test.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedure: Loading test. 53.65... Characteristics of Class II Equivalent Methods for PM2.5 § 53.65 Test procedure: Loading test. (a) Overview. (1) The loading tests are designed to quantify any appreciable changes in a candidate method sampler's...

  4. Parallelize Automated Tests in a Build and Test Environment

    OpenAIRE

    Durairaj, Selva Ganesh

    2016-01-01

    This thesis investigates the possibilities of finding solutions, in order to reduce the total time spent for testing and waiting times for running multiple automated test cases in a test framework. The “Automated Test Framework”, developed by Axis Communications AB, is used to write the functional tests to test both hardware and software of a resource. The functional tests that tests the software is considered in this thesis work. In the current infrastructure, tests are executed sequentially...

  5. 40 CFR 53.66 - Test procedure: Volatility test.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedure: Volatility test. 53.66... Characteristics of Class II Equivalent Methods for PM2.5 § 53.66 Test procedure: Volatility test. (a) Overview. This test is designed to ensure that the candidate method's losses due to volatility when sampling semi...

  6. Hemoglobin Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/hemoglobintest.html Hemoglobin Test To use the sharing features on this page, please enable JavaScript. What is a Hemoglobin Test? A hemoglobin test measures the levels of hemoglobin ...

  7. Amylase Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/amylasetest.html Amylase Test To use the sharing features on this page, please enable JavaScript. What is an Amylase Test? An amylase test measures the amount of amylase ...

  8. Hematocrit Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/hematocrittest.html Hematocrit Test To use the sharing features on this page, please enable JavaScript. What is a Hematocrit Test? A hematocrit test is a type of blood ...

  9. Procalcitonin Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/procalcitonintest.html Procalcitonin Test To use the sharing features on this page, please enable JavaScript. What is a Procalcitonin Test? A procalcitonin test measures the level of procalcitonin ...

  10. Nuclear Analyses of Indian LLCB Test Blanket System in ITER

    Science.gov (United States)

    Swami, H. L.; Shaw, A. K.; Danani, C.; Chaudhuri, Paritosh

    2017-04-01

    Heading towards the Nuclear Fusion Reactor Program, India is developing Lead Lithium Ceramic Breeder (LLCB) tritium breeding blanket for its future fusion Reactor. A mock-up of the LLCB blanket is proposed to be tested in ITER equatorial port no.2, to ensure the overall performance of blanket in reactor relevant nuclear fusion environment. Nuclear analyses play an important role in LLCB Test Blanket System design & development. It is required for tritium breeding estimation, thermal-hydraulic design, coolants process design, radioactive waste management, equipment maintenance & replacement strategies and nuclear safety. The nuclear behaviour of LLCB test blanket module in ITER is predicated in terms of nuclear responses such as tritium production, nuclear heating, neutron fluxes and radiation damages. Radiation shielding capability of LLCB TBS inside and outside bio-shield was also assessed to fulfill ITER shielding requirements. In order to supports the rad-waste and safety assessment, nuclear activation analyses were carried out and radioactivity data were generated for LLCB TBS components. Nuclear analyses of LLCB TBS are performed using ITER recommended nuclear analyses codes (i.e. MCNP, EASY), nuclear cross section data libraries (i.e. FENDL 2.1, EAF) and neutronic model (ITER C-lite v.l). The paper describes a comprehensive nuclear performance of LLCB TBS in ITER.

  11. Test re-test reliability and construct validity of the star-track test of manual dexterity

    DEFF Research Database (Denmark)

    Kildebro, Niels; Amirian, Ilda; Gögenur, Ismail

    2015-01-01

    Objectives. We wished to determine test re-test reliability and construct validity of the star-track test of manual dexterity. Design. Test re-test reliability was examined in a controlled study. Construct validity was tested in a blinded randomized crossover study. Setting. The study was performed...... at a university hospital in Denmark. Participants. A total of 11 subjects for test re-test and 20 subjects for the construct validity study were included. All subjects were healthy volunteers. Intervention. The test re-test trial had two measurements with 2 days pause in between. The interventions...... in the construct validity study included baseline measurement, intervention 1: fatigue, intervention 2: stress, and intervention 3: fatigue and stress. There was a 2 day pause between each intervention. Main outcome measure. An integrated measure of completion time and number of errors was used. Results. All...

  12. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    Inservice testing of safety-related components at nuclear power plants is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section 11 of the Code state test method and frequency requirements for pumps and valves, respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  13. Management of Port Operations

    OpenAIRE

    Gheorghe BASANU; Georgiana NUKINA

    2011-01-01

    The Management of port operation requires the proper and efficient use of port facility, equipment for cargo handling, berth facilities, waterways and roads. It also entails the use of effective communications system, storage facilities, and dockworkers. The whole activities mentioned above form the bulk of port operations. The aspiration of port operator is to get cargo through the gateway of ports as fast as possible on to other modes of transport (rail or road) with a minimal cost to them ...

  14. Magnesium Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  15. Lipase Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  16. Rubella Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  17. Mono Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  18. AMA Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  19. Solar-System Tests of Gravitational Theories

    Science.gov (United States)

    Shapiro, Irwin

    1997-01-01

    We are engaged in testing gravitational theory by means of observations of objects in the solar system. These tests include an examination of the Principle Of Equivalence (POE), the Shapiro delay, the advances of planetary perihelia, the possibility of a secular variation G in the "gravitational constant" G, and the rate of the de Sitter (geodetic) precession of the Earth-Moon system. These results are consistent with our preliminary results focusing on the contribution of Lunar Laser Ranging (LLR), which were presented at the seventh Marcel Grossmann meeting on general relativity. The largest improvement over previous results comes in the uncertainty for (eta): a factor of five better than our previous value. This improvement reflects the increasing strength of the LLR data. A similar analysis presented at the same meeting by a group at the Jet Propulsion Laboratory gave a similar result for (eta). Our value for (beta) represents our first such result determined simultaneously with the solar quadrupole moment from the dynamical data set. These results are being prepared for publication. We have shown how positions determined from different planetary ephemerides can be compared and how the combination of VLBI and pulse timing information can yield a direct tie between planetary and radio frames. We have continued to include new data in our analysis as they became available. Finally, we have made improvement in our analysis software (PEP) and ported it to a network of modern workstations from its former home on a "mainframe" computer.

  20. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  1. Allergy tests: Comparison between the Radio-Allergo-Sorbent Test (RAST) and cutaneous test as well as inhalative provocation test

    International Nuclear Information System (INIS)

    Langenstrass, J.A.

    1979-01-01

    As this publication has shown, the Radio-Allergo-Sorbent Test (RAST) is well suited for investigation programs. Absence of physical strain for the patient, precise reproducibility of the results and fair agreement with other test methods are above all qualities in favour of RAST. Its main disadvantages are the as yet rather restricted spectrum of allergens and expensiveness and high technical requirement. Substantial technical requirements are also involved with the inhalative provocation test, if properly carried out, but here the spectrum of allergens is by far greater. On the other hand, it exposes patients to great physical strain. The skin tests are most simple to carry out but present the largest position of misresults and are less reproducible than the two former procedures. The Radio-Immuno-Sorbent Test (RIST) can provide very useful results as a preliminary test but is also very costly owing to its high technical demands. - In conclusion, RAST is most conveniently used as a co-test in a complete investigation program where it constitutes a valuable aid. As a sole alternative to skin tests and inhalative provocation tests it is a yet not recommendable for the above-mentioned reasons. Although not able to replace the two conventional methods within the foreseeable future, it is expected to be used more widely on further development. (orig./MG) [de

  2. Re-test reliability of gustatory testing and introduction of the sensitive Taste-Drop-Test

    DEFF Research Database (Denmark)

    Fjaeldstad, A; Niklassen, A; Fernandes, H

    2018-01-01

    . Testing gustatory function can be important for diagnostics and assessment of treatment effects. However, the gustatory tests applied are required to be both sensitive and reliable.In this study, we investigate the re-test validity of popular Taste Strips gustatory test for gustatory screening....... Furthermore, we introduce a new sensitive Taste-Drop-Test, which was found to be superior for detecting a more accurate measure of tastant sensitivity....

  3. Energy Systems Test Area (ESTA). Power Systems Test Facilities

    Science.gov (United States)

    Situ, Cindy H.

    2010-01-01

    This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.

  4. Seismic testing

    International Nuclear Information System (INIS)

    Sollogoub, Pierre

    2001-01-01

    This lecture deals with: qualification methods for seismic testing; objectives of seismic testing; seismic testing standards including examples; main content of standard; testing means; and some important elements of seismic testing

  5. Proficiency Testing in Nondestructive Testing (NDT)

    International Nuclear Information System (INIS)

    Amry Amin Abbas; Suhairy Sani; Mohamad Pauzi Ismail; Abd Nassir Ibrahim

    2014-01-01

    Department of Standard Malaysia (DSM) launched myPTP programme on 31 December 2013 in accordance to ISO/IC 17043. The standard states the requirements for Proficiency Testing. The provider of these services is called Proficiency Testing Provider (PTP). The role of PTP is to compare the proficiency level between inspection bodies or laboratories. With the assistance of expert panel, the PTP will determine the assigned value as reference to be compared to the values obtained from the inspection bodies or laboratories. Quality wise, this services is important as participation will improve wuality of the inspection quality continuously and increase confidence level of client and improve safety level. Requirement of PT in NDT is mentioned in SC1.5- Specific Criteria for Accreditation of Mechanical Testing and Non-Destructive Testing (NDT) for MS ISO/IEC17025 and MTR2- MIBAS Technical Requirements for Accreditation of NDT. This paper explains and discusses the result of this proficiency test done on a number of NDT companies that participated. (author)

  6. Power Efficient Design of DisplayPort (7.0) Using Low-voltage differential signaling IO Standard Via UltraScale Field Programming Gate Arrays

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M.F.L.; Hussain, Dil muhammed Akbar

    2017-01-01

    Port (7.0) need be reduced. In this paper, a power efficient design for DisplayPort (7.0) is proposed using LVDS IO Standard. The proposed design is tested for different frequencies; 500 MHz, 700 MHz, 1.0 GHz, and 1.6 GHz. The design is implemented using vhdl in UltraScale FPGA. It is determined...... the designed vhdl based design of DisplayPort (7.0) can reduced 92% using LVDS IO Standard for all frequencies; 500 MHz, 700 MHz, 1.0 GHz, and 1.6 GHz, compared to vhdl based design of DisplayPort (7.0) without using IO Standard. The proposed design of vhdl based design of DisplayPort (7.0) using LVDS IO...... Standard offers no power consumption for DisplayPort (7.0) in standby mode. The vhdl based design of DisplayPort (7.0) using LVDS IO Standard will be helpful to process the high resolution video at low power consumption....

  7. Built-In Test Engine For Memory Test

    OpenAIRE

    McEvoy, Paul; Farrell, Ronan

    2004-01-01

    In this paper we will present an on-chip method for testing high performance memory devices, that occupies minimal area and retains full flexibility. This is achieved through microcode test instructions and the associated on-chip state machine. In addition, the proposed methodology will enable at-speed testing of memory devices. The relevancy of this work is placed in context with an introduction to memory testing and the techniques and algorithms generally used today.

  8. Schirmer test

    Science.gov (United States)

    Tear test; Tearing test; Dry eye test; Basal secretion test; Sjögren - Schirmer; Schirmer's test ... used when the eye doctor suspects you have dry eye. Symptoms include dryness of the eyes or excessive ...

  9. The Relationship between Anxiety and Test-Taking C-Test and Cloze-Test

    Science.gov (United States)

    Azimi, Mozhgan

    2016-01-01

    Anxiety has an important role in teaching and learning. If teachers can recognize which kind of tests create high anxiety then they will be able to omit these kinds of tests. Then, the results of test can probably show the students' knowledge more carefully. The subjects of the present study were sixty Iranian female junior university students.…

  10. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    This document discusses inservice testing of safety-related components at nuclear power plants which is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section XI of the Code state test method and frequency requirements for pumps and valves respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  11. The Windows serial port programming handbook

    CERN Document Server

    Bai, Ying

    2004-01-01

    The fundamentals of serial port communications. Serial port programming in ANSI C and Assembly languages for MS-DOS. Serial ports interface developed in VC++ 6.0. Serial port programming in Visual Basic. Serial port programming in LabVIEW. Serial port programming in MATLAB. Serial port programming in Smalltalk. Serial port programming in Java.

  12. A bright weekend: THE Port develops a better solution for the “Children of the Night”

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    THE Port Hackathon took place at CERN and Geneva’s Campus Biotech from 2 to 4 October. Among the various prototypes presented at the final event was a novel solution for the special mask that children suffering from xeroderma pigmentosum have to wear to reduce their risk of getting skin cancer. The whole initiative was triggered by an article published in one of the summer issues of the Bulletin.   Developing and testing the mask prototype at THE Port Hackathon, 2015. (Images: Andrey Loginov, Pierre Freyermuth, Antonio Bellotta/ THE Port)   “The improvements are really substantial and have made the president of the French Children of the Night Association really happy!” says Andy Butterworth from the team that worked on developing a prototype for a new mask during THE Port Hackathon. In his “normal” professional life, Andy is a radio-frequency expert working in the Beams department. During the hackathon, he worked with colleagues from CE...

  13. Maintaining and Researching Port Safety: A Case Study of the Port of Kaohsiung

    OpenAIRE

    Tseng, Po-Hsing.; Pilcher, Nick.

    2017-01-01

    Maintaining port safety in full conformity with IMO standards is a requisite for every port and country. To do this, understanding the challenges and human factors involved is key. To date, much research has shed valuable light on these factors and considered how to address them. One aspect that is often noted is that both maintaining port safety and researching port safety presents numerous challenges. This paper considers both these aspects in the context of a case study of port safety in K...

  14. Virtual Turbine Engine Test Bench Using MGET Test Device

    Science.gov (United States)

    Kho, Seonghee; Kong, Changduk; Ki, Jayoung

    2015-05-01

    Test device using virtual engine simulator can help reduce the number of engine tests through tests similar to the actual engine tests and repeat the test under the same condition, and thus reduce the engine maintenance and operating costs [1]. Also, as it is possible to easily implement extreme conditions in which it is hard to conduct actual tests, it can prevent engine damages that may happen during the actual engine test under such conditions. In this study, an upgraded MGET test device was developed that can conduct both real and virtual engine test by applying real-time engine model to the existing MGET test device that was developed and has been sold by the Company. This newly developed multi-purpose MGET test device is expected to be used for various educational and research purposes.

  15. Integrated Test and Evaluation Flight Test 3 Flight Test Plan

    Science.gov (United States)

    Marston, Michael Lawrence

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  16. Cost and Morbidity Analysis of Chest Port Insertion: Interventional Radiology Suite Versus Operating Room.

    Science.gov (United States)

    LaRoy, Jennifer R; White, Sarah B; Jayakrishnan, Thejus; Dybul, Stephanie; Ungerer, Dirk; Turaga, Kiran; Patel, Parag J

    2015-06-01

    To compare complications and cost, from a hospital perspective, of chest port insertions performed in an interventional radiology (IR) suite versus in surgery in an operating room (OR). This study was approved by an institutional review board and is HIPAA compliant. Medical records were retrospectively searched on consecutive chest port placement procedures, in the IR suite and the OR, between October 22, 2010 and February 26, 2013, to determine patients' demographic information and chest port-related complications and/or infections. A total of 478 charts were reviewed (age range: 21-85 years; 309 women, 169 men). Univariate and bivariate analyses were performed to identify risk factors associated with an increased complication rate. Cost data on 149 consecutive Medicare outpatients (100 treated in the IR suite; 49 treated in the OR) who had isolated chest port insertions between March 2012 and February 2013 were obtained for both the operative services and pharmacy. Nonparametric tests for heterogeneity were performed using the Kruskal-Wallis method. Early complications occurred in 9.2% (22 of 239) of the IR patients versus 13.4% (32 of 239) of the OR patients. Of the 478 implanted chest ports, 9 placed in IR and 18 placed in surgery required early removal. Infections from the ports placed in IR versus the OR were 0.25 versus 0.18 infections per 1000 catheters, respectively. Overall mean costs for chest port insertion were significantly higher in the OR, for both room and pharmacy costs (P chest ports in an OR setting was almost twice that of placement in the IR suite. Hospital costs to place a chest port were significantly lower in the IR suite than in the OR, whereas radiology and surgery patients did not show a significantly different rate of complications and/or infections. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Shipping emissions in ports

    OpenAIRE

    Merk, Olaf

    2014-01-01

    Shipping emissions in ports are substantial, accounting for 18 million tonnes of CO2 emissions, 0.4 million tonnes of NOx, 0.2 million of SOx and 0.03 million tonnes of PM10 in 2011. Around 85% of emissions come from containerships and tankers. Containerships have short port stays, but high emissions during these stays. Most of CO2 emissions in ports from shipping are in Asia and Europe (58%), but this share is low compared to their share of port calls (70%). European ports have much less emi...

  18. 19 CFR 101.3 - Customs service ports and ports of entry.

    Science.gov (United States)

    2010-04-01

    ... and Service Ports. Many of the ports listed were created by the President's message of March 3, 1913....S.C. 1). Subsequent orders of the President or of the Secretary of the Treasury which affected these... Port of the Delaware River and Bay described in T.D. 96-4. Perth Amboy New Mexico Albuquerque Including...

  19. Test report for core drilling ignitability testing

    International Nuclear Information System (INIS)

    Witwer, K.S.

    1996-01-01

    Testing was carried out with the cooperation of Westinghouse Hanford Company and the United States Bureau of Mines at the Pittsburgh Research Center in Pennsylvania under the Memorandum of Agreement 14- 09-0050-3666. Several core drilling equipment items, specifically those which can come in contact with flammable gasses while drilling into some waste tanks, were tested under conditions similar to actual field sampling conditions. Rotary drilling against steel and rock as well as drop testing of several different pieces of equipment in a flammable gas environment were the specific items addressed. The test items completed either caused no ignition of the gas mixture, or, after having hardware changes or drilling parameters modified, produced no ignition in repeat testing

  20. Neuropathy Tests

    Science.gov (United States)

    ... LD) Lactoferrin Lactose Tolerance Tests LDL Cholesterol LDL Particle Testing (LDL-P) Lead Legionella Testing Leptin Levetiracetam Lipase ... tests, such as computed tomography (CT) scans or magnetic resonance imaging ... suspected, additional testing may be performed to evaluate heart rate, blood ...

  1. Pinworm test

    Science.gov (United States)

    Oxyuriasis test; Enterobiasis test; Tape test ... diagnose this infection is to do a tape test. The best time to do this is in ... lay their eggs at night. Steps for the test are: Firmly press the sticky side of a ...

  2. Research on combination forecast of port cargo throughput based on time series and causality analysis

    Directory of Open Access Journals (Sweden)

    Chi Zhang

    2013-03-01

    Full Text Available Purpose: The purpose of this paper is to develop a combined model composed of grey-forecast model and Logistic-growth-curve model to improve the accuracy of forecast model of cargo throughput for the port. The authors also use the existing data of a current port to verify the validity of the combined model.Design/methodology/approach: A literature review is undertaken to find the appropriate forecast model of cargo throughput for the port. Through researching the related forecast model, the authors put together the individual models which are significant to study further. Finally, the authors combine two individual models (grey-forecast model and Logistic-growth-curve model into one combined model to forecast the port cargo throughput, and use the model to a physical port in China to testify the validity of the model.Findings: Test by the perceptional data of cargo throughput in the physical port, the results show that the combined model can obtain relatively higher forecast accuracy when it is not easy to find more information. Furthermore, the forecast made by the combined model are more accurate than any of the individual ones.Research limitations/implications: The study provided a new combined forecast model of cargo throughput with a relatively less information to improve the accuracy rate of the forecast. The limitation of the model is that it requires the cargo throughput of the port have an S-shaped change trend.Practical implications: This model is not limited by external conditions such as geographical, cultural. This model predicted the port cargo throughput of one real port in China in 2015, which provided some instructive guidance for the port development.Originality/value: This is the one of the study to improve the accuracy rate of the cargo throughput forecast with little information.

  3. Coverage of the Test of Memory Malingering, Victoria Symptom Validity Test, and Word Memory Test on the Internet: is test security threatened?

    Science.gov (United States)

    Bauer, Lyndsey; McCaffrey, Robert J

    2006-01-01

    In forensic neuropsychological settings, maintaining test security has become critically important, especially in regard to symptom validity tests (SVTs). Coaching, which can entail providing patients or litigants with information about the cognitive sequelae of head injury, or teaching them test-taking strategies to avoid detection of symptom dissimulation has been examined experimentally in many research studies. Emerging evidence supports that coaching strategies affect psychological and neuropsychological test performance to differing degrees depending on the coaching paradigm and the tests administered. The present study sought to examine Internet coverage of SVTs because it is potentially another source of coaching, or information that is readily available. Google searches were performed on the Test of Memory Malingering, the Victoria Symptom Validity Test, and the Word Memory Test. Results indicated that there is a variable amount of information available about each test that could threaten test security and validity should inappropriately interested parties find it. Steps that could be taken to improve this situation and limitations to this exploration are discussed.

  4. Test techniques for fracture mechanics testing

    International Nuclear Information System (INIS)

    Schwalbe, K.H.

    1980-01-01

    Test methods for fracture mechanics tests are described. Two groups of techniques are distinguished: Those for measurement of stable crack growth and those for determination of the loading parameters. (orig.) [de

  5. 76 FR 37007 - Safety Zone; Stockton Ports Baseball Club Fourth of July Fireworks Display, Stockton, CA

    Science.gov (United States)

    2011-06-24

    ..., performance, design, or operation; test methods; sampling procedures; and related management systems practices...-AA00 Safety Zone; Stockton Ports Baseball Club Fourth of July Fireworks Display, Stockton, CA AGENCY... inspection or copying two locations: the Docket Management Facility (M-30), U.S. Department of Transportation...

  6. Evaluation of the Necessity of Port Fixation in Central Venous Port Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Su; Kim, Hyung Pil [Inje University Pusan Paik Hospital, Busan (Korea, Republic of); Bae, Jae Ik; Won, Je Hwan [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2010-06-15

    The technical success and complications were especially focused on and evaluated the need for fixation of a port under fluoroscopic guidance placement of the totally implantable central venous access ports for long term central venous access. Two hundred eighty nine consecutive patients (170 men, 119 women, mean age: 52-year-old) who underwent venous port implantation for the administration of chemotherapy were followed over a 1-month period. The procedures were performed in the angiographic suite by an interventional radiologist and all access was through the right jugular vein, except for the patients who had undergone a right mastectomy. The procedures were performed in the following order: 1) venous puncture, 2) making a pocket, 3) catheter tunneling, 4) port insertion, 5) catheter sizing, and 6) insertion. A port which was connected to the tunneled catheter was inserted into the minimally sized subcutaneous pocket with the aid of a small retractor. A follow-up was performed with medical records and chest radiographs. The follow-up period for evaluating the venous port ranged from 59 to 329 days (mean: 175 days) The procedures performed to gain right jugular vein access were successful without difficulty in all cases. The 18 patients that underwent procedures to gain left jugular vein access encountered some difficulty upon insertion of a catheter into the SVC due to encountering the tortuous left brachiocephalic vein. No complications occurred during and immediately after the procedure. In one case the port chamber rotated within the subcutaneous pocket; however, no catheter migration or malfunction occurred. If port insertion was followed by catheter insertion, the port chamber can be tightly implanted in the minimally sized pocket. This would avoid the need for fixation of the catheter to the port chamber leading into the pocket

  7. Large scale reflood test with cylindrical core test facility (CCTF). Core I. FY 1979 tests

    International Nuclear Information System (INIS)

    Murao, Yoshio; Akimoto, Hajime; Okubo, Tsutomu; Sudoh, Takashi; Hirano, Kenmei

    1982-03-01

    This report presents the results of analysis of the data obtained in the CCTF Core I test series (19 tests) in FY. 1979 as an interim report. The Analysis of the test results showed that: (1) The present safety evaluation model on the reflood phenomena during LOCA conservatively represents the phenomena observed in the tests except for the downcomer thermohydrodynamic behavior. (2) The downcomer liquid level rose slowly and it took long time for the water to reach a terminal level or the spill-over level. It was presume that such a results was due to an overly conservative selection of the ECC flow rate. This presumption will be checked against a future test result for an increased flow rate. The loop-seal-water filling test was unsuccessful due to a premature power shutdown by the core protection circuit. The test will be conducted again. The tests to be performed in the future are summerized. Tests for investigation of the refill phenomena were also proposed. (author)

  8. Motivation and Test Anxiety in Test Performance across Three Testing Contexts: The CAEL, CET, and GEPT

    Science.gov (United States)

    Cheng, Liying; Klinger, Don; Fox, Janna; Doe, Christine; Jin, Yan; Wu, Jessica

    2014-01-01

    This study examined test-takers' motivation, test anxiety, and test performance across a range of social and educational contexts in three high-stakes language tests: the Canadian Academic English Language (CAEL) Assessment in Canada, the College English Test (CET) in the People's Republic of China, and the General English Proficiency Test (GEPT)…

  9. Randomization tests

    CERN Document Server

    Edgington, Eugene

    2007-01-01

    Statistical Tests That Do Not Require Random Sampling Randomization Tests Numerical Examples Randomization Tests and Nonrandom Samples The Prevalence of Nonrandom Samples in Experiments The Irrelevance of Random Samples for the Typical Experiment Generalizing from Nonrandom Samples Intelligibility Respect for the Validity of Randomization Tests Versatility Practicality Precursors of Randomization Tests Other Applications of Permutation Tests Questions and Exercises Notes References Randomized Experiments Unique Benefits of Experiments Experimentation without Mani

  10. Galileo battery testing and the impact of test automation

    Science.gov (United States)

    Pertuch, W. T.; Dils, C. T.

    1985-01-01

    Test complexity, changes of test specifications, and the demand for tight control of tests led to the development of automated testing used for Galileo and other projects. The use of standardized interfacing, i.e., IEEE-488, with desktop computers and test instruments, resulted in greater reliability, repeatability, and accuracy of both control and data reporting. Increased flexibility of test programming has reduced costs by permitting a wide spectrum of test requirements at one station rather than many stations.

  11. Intake port

    Science.gov (United States)

    Mendler, Edward Charles

    2005-02-01

    The volumetric efficiency and power of internal combustion engines is improved with an intake port having an intake nozzle, a venturi, and a surge chamber. The venturi is located almost halfway upstream the intake port between the intake valves and the intake plenum enabling the venturi throat diameter to be exceptionally small for providing an exceptionally high ram velocity and an exceptionally long and in turn high efficiency diffuser flowing into the surge chamber. The intake port includes an exceptionally large surge chamber volume for blow down of the intake air into the working cylinder of the engine.

  12. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  13. Shutdown dose rates at ITER equatorial ports considering radiation cross-talk from torus cryopump lower port

    Energy Technology Data Exchange (ETDEWEB)

    Juárez, Rafael, E-mail: rjuarez@ind.uned.es [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Pampin, Raul [F4E, Torres Diagonal Litoral B3, Josep Pla 2, Barcelona 08019 (Spain); Levesy, Bruno [ITER Organization, 13115 Route de Vinon sur Verdon, St Paul Lez Durance (France); Moro, Fabio [ENEA, Via Enrico Fermi 45, Frascati, Rome (Italy); Suarez, Alejandro [ITER Organization, 13115 Route de Vinon sur Verdon, St Paul Lez Durance (France); Sanz, Javier [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain)

    2015-11-15

    Shutdown dose rates for planned maintenance purposes is an active research field in ITER. In this work the radiation (neutron and gamma) cross-talk between ports in the most conservative case foreseen in ITER is investigated: the presence of a torus cryopump lower port, mostly empty for pumping efficiency reasons. There will be six of those ports: #4, #6, #10, #12, #16 and #18. The equatorial ports placed above them will receive a significant amount of additional radiation affecting the shutdown dose rates during in situ maintenance activities inside the cryostat, and particularly in the port interspace area. In this study a general situation to all the equatorial ports placed above torus cryopump lower ports is considered: a generic diagnostics equatorial port placed above the torus cryopump lower port (LP#4). In terms of shutdown dose rates at equatorial port interspace after 10{sup 6} s of cooling time, 405 μSv/h has been obtained, of which 160 μSv/h (40%) are exclusively due to radiation cross-talk from a torus cryopump lower port. Equatorial port activation due to only “local neutrons” contributes 166 μSv/h at port interspace, showing that radiation cross-talk from such a lower port is a phenomenon comparable in magnitude to the neutron leakage though the equatorial port plug.

  14. Tensile testing

    CERN Document Server

    2004-01-01

    A complete guide to the uniaxial tensile test, the cornerstone test for determining the mechanical properties of materials: Learn ways to predict material behavior through tensile testing. Learn how to test metals, alloys, composites, ceramics, and plastics to determine strength, ductility and elastic/plastic deformation. A must for laboratory managers, technicians, materials and design engineers, and students involved with uniaxial tensile testing. Tensile Testing , Second Edition begins with an introduction and overview of the test, with clear explanations of how materials properties are determined from test results. Subsequent sections illustrate how knowledge gained through tensile tests, such as tension properties to predict the behavior (including strength, ductility, elastic or plastic deformation, tensile and yield strengths) have resulted in improvements in materals applications. The Second Edition is completely revised and updated. It includes expanded coverage throughout the volume on a variety of ...

  15. Ham test

    Science.gov (United States)

    Acid hemolysin test; Paroxysmal nocturnal hemoglobinuria - Ham test; PNH - Ham test ... BJ. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. Philadelphia, PA: Elsevier ...

  16. Test Re-Test Reliability of Four Versions of the 3-Cone Test in Non-Athletic Men

    Directory of Open Access Journals (Sweden)

    Jason G. Langley, Robert D. Chetlin

    2017-03-01

    Full Text Available Until recently, measurement and evaluation in sport science, especially agility testing, has not always included key elements of proper test construction. Often tests are published without reporting reliability and validity analysis for a specific population. The purpose of the present study was to examine the test re-test reliability of four versions of the 3-Cone Test (3CT, and provide guidance on proper test construction for testing agility in athletic populations. Forty male students enrolled in classes in the Department of Physical Education at a mid-Atlantic university participated. On each of test day participants performed 10 trials. In random order, they performed three trials to the right (3CTR, standard test, three to the left (3CTL, and two modified trials (3CTAR and 3CTAL, which included a reactive component in which a visual cue was given to indicate direction. Intra-class correlation coefficients (ICC indicated a moderate to high reliability for the four tests, 3CTR 0.79 (0.64-0.88, 95%CI, 3CTL 0.73 (0.55-0.85, 3CTAR 0.85(0.74-0.92, and 3CTAL 0.79 (0.64-0.88. Small standard error of the measurement (SEM was found; range 0.09 to 0.10. Pearson correlations between tests were high (0.82-0.92 on day one as well as day two (0.72-0.85. These results indicate each version of the 3-Cone Test is reliable; however, further tests are needed with specific athletic populations. Only the 3CTAR and 3CTAL are tests of agility due to the inclusion of a reactive component. Future studies examining agility testing and training should incorporate technological elements, including automated timing systems and motion capture analysis. Such instrumentation will allow for optimal design of tests that simulate sport-specific game conditions.

  17. Allergy testing - skin

    Science.gov (United States)

    Patch tests - allergy; Scratch tests - allergy; Skin tests - allergy; RAST test; Allergic rhinitis - allergy testing; Asthma - allergy testing; Eczema - allergy testing; Hayfever - allergy testing; Dermatitis - allergy testing; Allergy testing; ...

  18. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  19. Integrating Test-Form Formatting into Automated Test Assembly

    Science.gov (United States)

    Diao, Qi; van der Linden, Wim J.

    2013-01-01

    Automated test assembly uses the methodology of mixed integer programming to select an optimal set of items from an item bank. Automated test-form generation uses the same methodology to optimally order the items and format the test form. From an optimization point of view, production of fully formatted test forms directly from the item pool using…

  20. Three-Dimensional Model Test Study on the Existing Caisson Breakwater at Port of Castellon, Spain

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen Harck; Andersen, Thomas Lykke

    This report present the results of 3-D physical model tests (length scale 1:60) carried out in a wave basin at Department of Civil Engineering, Aalborg University (AAU) on behalf of the client; BP OIL ESPAÑA. Associate Prof. Thomas Lykke Andersen and M.Sc. Jørgen Quvang Harck Nørgaard were in cha...

  1. Testing and interfacing intelligent power supplies for the Los Alamos National Laboratory Accelerator Complex

    International Nuclear Information System (INIS)

    Sturrock, J.C.; Cohen, S.; Weintraub, B.L.; Hayden, D.J.; Archuleta, S.F.

    1992-01-01

    New high-current, high-precision microprocessor-controlled power supplies, built by Alpha Scientific Electronics of Hayward, CA, have been installed at the Los Alamos National Laboratory Accelerator Complex. Each unit has sophisticated microprocessor control on-board and communicates via RS-422 (serial communications). The units use a high level ASCII-based control protocol. Performance tests were conducted to verify adherence to specification and to ascertain ultimate long-term stability. The ''front-end'' software used by the accelerator control system has been written to accommodate these new devices. The supplies are interfaced to the control system through a terminal server port connected to the site-wide ediernet backbone. Test design and results as well as details of the software implementation for the analog and digital control of the supplies through the accelerator control system are presented

  2. Reliability of two social cognition tests: The combined stories test and the social knowledge test.

    Science.gov (United States)

    Thibaudeau, Élisabeth; Cellard, Caroline; Legendre, Maxime; Villeneuve, Karèle; Achim, Amélie M

    2018-04-01

    Deficits in social cognition are common in psychiatric disorders. Validated social cognition measures with good psychometric properties are necessary to assess and target social cognitive deficits. Two recent social cognition tests, the Combined Stories Test (COST) and the Social Knowledge Test (SKT), respectively assess theory of mind and social knowledge. Previous studies have shown good psychometric properties for these tests, but the test-retest reliability has never been documented. The aim of this study was to evaluate the test-retest reliability and the inter-rater reliability of the COST and the SKT. The COST and the SKT were administered twice to a group of forty-two healthy adults, with a delay of approximately four weeks between the assessments. Excellent test-retest reliability was observed for the COST, and a good test-retest reliability was observed for the SKT. There was no evidence of practice effect. Furthermore, an excellent inter-rater reliability was observed for both tests. This study shows a good reliability of the COST and the SKT that adds to the good validity previously reported for these two tests. These good psychometrics properties thus support that the COST and the SKT are adequate measures for the assessment of social cognition. Copyright © 2018. Published by Elsevier B.V.

  3. Irradiation Effects Test Series: Test IE-3. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, L. C.; Allison, C. M.; Croucher, D. W.; Ploger, S. A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m/sup 2/. After a flow reduction to 2120 kg/s-m/sup 2/, film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions.

  4. RIA testing capability of the transient reactor test facility

    International Nuclear Information System (INIS)

    Crawford, D.C.; Swanson, R.W.

    1999-01-01

    The advent of high-burnup fuel implementation in LWRs has generated international interest in high-burnup LWR fuel performance. Recent testing under simulated RIA conditions has demonstrated that certain fuel designs fail at peak fuel enthalpy values that are below existing regulatory criteria. Because many of these tests were performed with non-prototypically aggressive test conditions (i.e., with power pulse widths less than 10 msec FWHM and with non-protoypic coolant configurations), the results (although very informative) do not indisputably identify failure thresholds and fuel behavior. The capability of the TREAT facility to perform simulated RIA tests with prototypic test conditions is currently being evaluated by ANL personnel. TREAT was designed to accommodate test loops and vehicles installed for in-pile transient testing. During 40 years of TREAT operation and fuel testing and evaluation, experimenters have been able to demonstrate and determine the transient behavior of several types of fuel under a variety of test conditions. This experience led to an evolution of test methodology and techniques which can be employed to assess RIA behavior of LWR fuel. A pressurized water loop that will accommodate RIA testing of LWR and CANDU-type fuel has completed conceptual design. Preliminary calculations of transient characteristics and energy deposition into test rods during hypothetical TREAT RIA tests indicate that with the installation of a pressurized water loop, the facility is quite capable of performing prototypic RIA testing. Typical test scenarios indicate that a simulated RIA with a 72 msec FWHM pulse width and energy deposition of 1200 kJ/kg (290 cal/gm) is possible. Further control system enhancements would expand the capability to pulse widths as narrow as 40 msec. (author)

  5. Trichomonas Testing

    Science.gov (United States)

    ... Genetic Tests for Targeted Cancer Therapy Glucose Tests Gonorrhea Testing Gram Stain Growth Hormone Haptoglobin hCG Pregnancy ... With some NAATs, samples collected for testing of gonorrhea and chlamydial infections can also be used to ...

  6. Condensation heat transfer and pressure drop of R-410A in flat aluminum multi-port tubes

    Science.gov (United States)

    Kim, Nae-Hyun

    2018-02-01

    Brazed heat exchangers with aluminum flat multi-port tubes are being used as condensers of residential air-conditioners. In this study, R-410A condensation tests were conducted in four multi-port tubes having a range of hydraulic diameter (0.78 ≤ Dh ≤ 0.95 mm). The test range covered the mass flux from 100 to 400 kg/m2 s and the heat flux at 3 kW/m2, which are typical operating conditions of residential air conditioners. Results showed that both the heat transfer coefficient and the pressure drop increased as the hydraulic diameter decreased. The effect of hydraulic diameter on condensation heat transfer was much larger than the predictions of existing correlations for the range of investigation. Comparison of the data with the correlations showed that some macro-channel tube correlations and mini-channel tube correlations reasonably predicted the heat transfer coefficient. However, macro-channel correlations highly overpredicted the pressure drop data.

  7. Science Library of Test Items. Volume Nine. Mastery Testing Programme. [Mastery Tests Series 1.] Tests M1-M13.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of the first 13 tests are provided. Skills to be tested include: (1) reading a table; (2) using a biological key; (3) identifying chemical symbols; (4) identifying parts of a human body; (5) reading a line graph; (6) identifying electronic and…

  8. Rail Impact Testing. Test Operations Procedure (TOP)

    Science.gov (United States)

    2008-09-15

    impact test. The rail impact test is used to verify structural integrity of the test item and the adequacy of the tie-down system and tie-down...strength of provisions, connection and supporting structural frame, paragraph 5.2.3 ** Superscript...parts, to include outriggers and booms) without advanced approval by SDDCTEA. Torque nuts on wire rope clips to their correct value. Torque cable

  9. Coombs test

    Science.gov (United States)

    Direct antiglobulin test; Indirect antiglobulin test; Anemia - hemolytic ... No special preparation is necessary for this test. ... There are 2 types of the Coombs test: Direct Indirect The direct ... that are stuck to the surface of red blood cells. Many diseases ...

  10. Comparison of test protocols for standard room/corner tests

    Science.gov (United States)

    R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens

    1998-01-01

    As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...

  11. Generic Diagnostic Port Integration for the Equatorial Port Plug of ITER

    International Nuclear Information System (INIS)

    Doceul, L.; Chappuis, Ph.; Portafaix, Ch.; Guillaume, T.; Bruyere, Ch.; Walker, Ch.; Ingesson, Ch.; Ciattaglia, E.; Salasca, S.; Eric, T.

    2006-01-01

    ITER requires an extensive set of diagnostic systems to provide several key functions such as protection of the device, input to plasma control systems and evaluation of the plasma performance. Most of these diagnostics system are to be integrated in port plugs, which are water cooled stainless steel structures (approximately: 50 t, 2 m x 2 m x 4 m) inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, supporting the diagnostic equipment (within the primary vacuum, on the primary vacuum boundary and in the port interspace). CEA (Commissariat l'Energie Atomique) has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug EQ01. The specific CEA contributions were to perform the general engineering, structural and thermal analysis. These detailed analysis have highlighted some design issues which were worked out through different solutions. This paper will contain the description of the engineering activities performed such as: - The conceptual design of the EQ01 and the associated diagnostics, such as the visible and infrared optical diagnostic, - The static mechanical calculations, taking into account the electromagnetic loads occurring during fast transient plasma events, - The dynamic calculation constituted of modal and transient analysis under the same electromagnetic loads to estimate the dynamic amplification factor due to the resonance phenomenon, - The thermal assessment under the neutronic load of the water-cooled stainless steel structure, - The seismic response of the port plug inside the vacuum vessel, taking into account the ground spectra and soil conditions in the Cadarache site. (author)

  12. Chloride Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/chloridebloodtest.html Chloride Blood Test To use the sharing features on this page, please enable JavaScript. What is a Chloride Blood Test? A chloride blood test measures the ...

  13. Bilirubin Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/bilirubinbloodtest.html Bilirubin Blood Test To use the sharing features on this page, please enable JavaScript. What is a Bilirubin Blood Test? A bilirubin blood test measures the ...

  14. National Ignition Facility TestController for automated and manual testing

    Energy Technology Data Exchange (ETDEWEB)

    Zielinski, Jason, E-mail: fishler2@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2012-12-15

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  15. National Ignition Facility TestController for automated and manual testing

    International Nuclear Information System (INIS)

    Zielinski, Jason

    2012-01-01

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  16. Reliability of activation cross sections for estimation of shutdown dose rate in the ITER port cell and port interspace

    Science.gov (United States)

    García, Raquel; García, Mauricio; Ogando, Francisco; Pampin, Raúl; Sanz, Javier

    2017-09-01

    This paper explores the quality of available activation cross section (XS) data for accurate Shutdown Dose Rate (SDDR) prediction in the ITER Port Cell and Port Interspace areas, where different maintenance activities are foreseen. For this purpose the EAF library (2007 and 2010 versions) has been investigated, as it is typically used by the ITER community. Based on both reports/papers on SDDR in ITER and own calculations, major nuclides contributing to the SDDR coming from the activation of i) relevant materials placed in ITER and ii) candidate materials for the bioshield plug as L2N and barite concretes, are identified. Then, relevant production pathways are obtained. EAF XS quality for all pathways is checked following the procedure used for validating and testing the successive EAF versions. Also, possible improvements from using the TENDL-2015 library are assessed by comparing EAF and TENDL XS with available differential experimental data from EXFOR. Results point out that most of the activation XS related to materials currently placed in ITER are reliable, and only a few need improvement. Also, many of the XS related to both L2N and barite concretes need further work for validation.

  17. HSV Serologic Testing for Pregnant Women: Willingness to Be Tested and Factors Affecting Testing

    Directory of Open Access Journals (Sweden)

    David A. Baker

    2011-01-01

    Full Text Available Objective. This prospective study was undertaken to evaluate pregnant women's willingness to undergo HSV type-specific serologic testing and factors affecting willingness in an obstetrics/gynecology ambulatory unit. Methods. At prenatal Visit 1, pregnant women (n=303 with no history of HSV-2 were tested for HSV-1/HSV-2 before and after they received counseling on genital and neonatal herpes. Results. In both the Unwilling Subgroup and the group that changed from being willing to being unwilling, the most common reasons for choosing not to be tested were not being at risk for genital herpes, being tested is too personal, and concern about what will be done with the results. Of the 134 participants in the Willing/Tested Subgroup, 27 (20% were HSV-2 seropositive and 81 (60% were HSV-1 seropositive. Conclusions. These results support the feasibility of HSV serologic testing and counseling in pregnant women.

  18. Getting Port Governance Right

    DEFF Research Database (Denmark)

    de Langen, Peter; Saragiotis, Periklis

    2018-01-01

    This chapter discusses the relevance of ports for economic development and next identifies port governance as a critical determinant of a well-functioning port industry. While in the past decades privately owned terminal operating companies have emerged and contributed to more efficient supply ch...

  19. Reduced-port robotic total mesorectal resection for rectal cancer using a single-port access: a technical note.

    Science.gov (United States)

    Bae, Sung Uk; Jeong, Woon Kyung; Baek, Seong Kyu

    2017-12-01

    Single-port laparoscopic surgery has some advantages, including improved cosmetic outcomes and minimized parietal trauma. However, pure single-port laparoscopic rectal cancer surgery is challenging because of the difficulties in creating triangulation and applying the laparoscopic staplers with sufficient distal margins in the narrow pelvic cavity. Recently, a reduced-port robotic operation with a robotic single-port access plus one wristed robotic arm for colon cancer was introduced to overcome the limitations of single-port laparoscopic rectal surgery. Single-port laparoscopic surgery has some advantages, including improved cosmetic outcomes and minimized parietal trauma. However, the pure single-port laparoscopic rectal cancer operation is challenging. Recently, a reduced-port robotic operation with a robotic single-port access plus one wristed robotic arm for colon cancer was introduced to overcome the limitations of single-port laparoscopic rectal surgery. We performed a single-port plus an additional port robotic operation using a robotic single-port access through the umbilical incision, and the wristed robotic instruments were inserted through an additional robotic port in the right lower quadrant. The total operative and docking times were 310 min and 25 min, respectively. The total number of lymph nodes harvested was 12, and the proximal and distal resection margins were 11.1 and 2 cm, respectively. The patient was discharged on postoperative day 12 uneventfully. Based on a representative case, reduced-port robotic total mesorectal excision for rectal cancer using the single-port access appears to be feasible and safe. This approach could overcome the limitations of single-port laparoscopic rectal surgery.

  20. Simulation-Based Planning and Control of Transport Flows in Port Logistic Systems

    Directory of Open Access Journals (Sweden)

    Antonio Diogo Passos Lima

    2015-01-01

    Full Text Available In highly dynamic and uncertain transport conditions, transport transit time has to be continuously monitored so that the service level is ensured at a proper cost. The aim of this research is to propose and to test a procedure which allows an agile planning and control of transport flows in port logistic systems. The procedure couples an agent-based simulation and a queueing theory model. In this paper, the transport scheduling performed by an agent at the intermodal terminal was taken into consideration. The decision-making agent takes into account data which is acquired in remote points of the system. The obtained results indicate the relevance of continuously considering, for the transport planning and control, the expected transit time and further waiting times along port logistic systems.

  1. AFFTC Instruction 99-1, Test and Evaluation Test Plans

    National Research Council Canada - National Science Library

    Crane, Roger

    2002-01-01

    .... Test Information Sheets (TISs) are actually appendices to test plans and contain sufficient information for use by a flight test engineer to develop flight test cards and for management to discern the overall technical approach being taken...

  2. Test/score/report: Simulation techniques for automating the test process

    Science.gov (United States)

    Hageman, Barbara H.; Sigman, Clayton B.; Koslosky, John T.

    1994-01-01

    A Test/Score/Report capability is currently being developed for the Transportable Payload Operations Control Center (TPOCC) Advanced Spacecraft Simulator (TASS) system which will automate testing of the Goddard Space Flight Center (GSFC) Payload Operations Control Center (POCC) and Mission Operations Center (MOC) software in three areas: telemetry decommutation, spacecraft command processing, and spacecraft memory load and dump processing. Automated computer control of the acceptance test process is one of the primary goals of a test team. With the proper simulation tools and user interface, the task of acceptance testing, regression testing, and repeatability of specific test procedures of a ground data system can be a simpler task. Ideally, the goal for complete automation would be to plug the operational deliverable into the simulator, press the start button, execute the test procedure, accumulate and analyze the data, score the results, and report the results to the test team along with a go/no recommendation to the test team. In practice, this may not be possible because of inadequate test tools, pressures of schedules, limited resources, etc. Most tests are accomplished using a certain degree of automation and test procedures that are labor intensive. This paper discusses some simulation techniques that can improve the automation of the test process. The TASS system tests the POCC/MOC software and provides a score based on the test results. The TASS system displays statistics on the success of the POCC/MOC system processing in each of the three areas as well as event messages pertaining to the Test/Score/Report processing. The TASS system also provides formatted reports documenting each step performed during the tests and the results of each step. A prototype of the Test/Score/Report capability is available and currently being used to test some POCC/MOC software deliveries. When this capability is fully operational it should greatly reduce the time necessary

  3. Nuclear systems and testing programs for ITER. Progress report for FY 1998

    International Nuclear Information System (INIS)

    1998-01-01

    The effort during this performance period focused on a number of TBWG activities (including test module design and analysis) that were identified and agreed upon (in the presence of the ITER Director and Deputy Director) at TBWG-4. These include: (a) DEMO test module design and performance analysis under pulsed operation; (b) Test program operation plan; (c) Test port design and analysis; (d) Decay heat calculations and safety analysis; (e) Further discussion among the parties to define collaboratory on R and D for the test program as well as possible collaboration on the construction and operation of test articles; (f) Remote handling and ancillary equipment; (g) Criteria for qualifying a blanket module or submodule for actual insertion and testing in ITER; (h) Definition of test module instrumentation and verification of capability to perform in the ITER fusion environment (magnetic field, radiation, heating, etc.); and (i) Analysis to show that the results to be obtained from the test modules as designed can be extrapolated to DEMO and reactor conditions (e.g., higher wall loads and the need to demonstrate tritium self-sufficiency). The main achievements during this performance period include: (1) updating and finalizing the US DDDs for the ITER Blanket Program to form part of the ITER Final Design Report (FDR). Specific revisions were in response to the minimal lithium volume test blanket design requirements and safety impact and (2) evaluating the feasibility of the US test program, including instrumentation and the benefits of the ITER test program. Details of this assessment, including solid breeder and liquid breeder blanket test plans, are documented in UCLA-IFNT-13 (attached). In addition, dose mapping calculations were performed for the ITER Building, including equipment and layout of coolant pipes/heat exchangers. A report on ITER Building dose calculations was sent to UD ITER management and to the Garching Task Coordinator in April, 1998. The report

  4. Construction and commissioning test report of the CEDM test facility

    Energy Technology Data Exchange (ETDEWEB)

    Chung, C. H.; Kim, J. T.; Park, W. M.; Youn, Y. J.; Jun, H. G.; Choi, N. H.; Park, J. K.; Song, C. H.; Lee, S. H.; Park, J. K

    2001-02-01

    The test facility for performance verification of the control element drive mechanism (CEDM) of next generation power plant was installed at the site of KAERI. The CEDM was featured a mechanism consisting of complicated mechanical parts and electromagnetic control system. Thus, a new CEDM design should go through performance verification tests prior to it's application in a reactor. The test facility can simulate the reactor operating conditions such as temperature, pressure and water quality and is equipped with a test chamber to accomodate a CEDM as installed in the power plant. This test facility can be used for the following tests; endurance test, coil cooling test, power measurement and reactivity rod drop test. The commissioning tests for the test facility were performed up to the CEDM test conditions of 320 C and 150 bar, and required water chemistry was obtained by operating the on-line water treatment system.

  5. Construction and commissioning test report of the CEDM test facility

    International Nuclear Information System (INIS)

    Chung, C. H.; Kim, J. T.; Park, W. M.; Youn, Y. J.; Jun, H. G.; Choi, N. H.; Park, J. K.; Song, C. H.; Lee, S. H.; Park, J. K.

    2001-02-01

    The test facility for performance verification of the control element drive mechanism (CEDM) of next generation power plant was installed at the site of KAERI. The CEDM was featured a mechanism consisting of complicated mechanical parts and electromagnetic control system. Thus, a new CEDM design should go through performance verification tests prior to it's application in a reactor. The test facility can simulate the reactor operating conditions such as temperature, pressure and water quality and is equipped with a test chamber to accomodate a CEDM as installed in the power plant. This test facility can be used for the following tests; endurance test, coil cooling test, power measurement and reactivity rod drop test. The commissioning tests for the test facility were performed up to the CEDM test conditions of 320 C and 150 bar, and required water chemistry was obtained by operating the on-line water treatment system

  6. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  7. Oral Solid Dosage Form Disintegration Testing - The Forgotten Test.

    Science.gov (United States)

    Al-Gousous, Jozef; Langguth, Peter

    2015-09-01

    Since its inception in the 1930s, disintegration testing has become an important quality control (QC) test in pharmaceutical industry, and disintegration test procedures for various dosage forms have been described by the different pharmacopoeias, with harmonization among them still not quite complete. However, because of the fact that complete disintegration does not necessarily imply complete dissolution, much more research has been focused on dissolution rather than on disintegration testing. Nevertheless, owing to its simplicity, disintegration testing seems to be an attractive replacement to dissolution testing as recognized by the International Conference on Harmonization guidelines, in some cases. Therefore, with proper research being carried out to overcome the associated challenges, the full potential of disintegration testing could be tapped saving considerable efforts allocated to QC testing and quality assurance. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  8. Acceptance Testing Of Web Applications With Test Description Language

    Directory of Open Access Journals (Sweden)

    Łukasz Olek

    2014-01-01

    Full Text Available Acceptance tests are usually created by a client after a part of a system is implemented. However, some methodologies propose the elaboration of test cases before implementing a system. This approach increases the probability of system implementation that fulfills requirements, but may be problematic for customers and testers. To allow acceptance testing in such conditions, we propose to define test cases by recording them on an interactive mockup (a low detailed user-interface prototype. The paper focuses on Test Description Language, a notation used to store test cases.

  9. Large-Grain Superconducting Gun Cavity Testing Program Phase One Closing Report

    Energy Technology Data Exchange (ETDEWEB)

    Hammons, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Bellavia, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Belomestnykh, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cullen, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Dai, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Degen, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Hahn, H. [Brookhaven National Lab. (BNL), Upton, NY (United States); Masi, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); McIntyre, G. [Brookhaven National Lab. (BNL), Upton, NY (United States); Schultheiss, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Seda, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Kellerman, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tallerico, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Todd, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tuozzolo, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Xu, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Than, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2013-10-31

    This report details the experimental configuration and RF testing results for the first phase of a large-grained niobium electron gun cavity testing program being conducted in the Small Vertical Testing Facility in the Collider-Accelerator Department. This testing is meant to explore multi-pacting in the cavity and shed light on the behavior of a counterpart cavity of identical geometry installed in the Energy Recovery LINAC being constructed in the Collider-Accelerator Department at Brookhaven National Laboratory. This test found that the Q of the large-grained cavity at 4 K reached ~6.5 × 108 and at 2 K reached a value of ~6 × 109. Both of these values are about a factor of 10 lower than would be expected for this type of cavity given the calculated surface resistance and the estimated geometry factor for this half-cell cavity. In addition, the cavity reached a peak voltage of 0.6 MV before there was sig-nificant decline in the Q value and a substantial increase in field emission. This relatively low volt-age, coupled with the low Q and considerable field emission suggest contamination of the cavity interior, possibly during experimental assembly. The results may also suggest that additional chemical etching of the interior surface of the cavity may be beneficial. Throughout the course of testing, various challenges arose including slow helium transfer to the cryostat and cable difficulties. These difficulties and others were eventually resolved, and the re-port discusses the operating experience of the experiment thus far and the plans for future work aimed at exploring the nature of multipacting with a copper cathode inserted into the cavity.

  10. Post-test analysis of PANDA test P4

    International Nuclear Information System (INIS)

    Hart, J.; Woudstra, A.; Koning, H.

    1999-01-01

    The results of a post-test analysis of the integral system test P4, which has been executed in the PANDA facility at PSI in Switzerland within the framework of Work Package 2 of the TEPSS project are presented. The post-test analysis comprises an evaluation of the PANDA test P4 and a comparison of the test results with the results of simulations using the RELAPS/MOD3.2, TRAC-BF1, and MELCOR 1.8.4 codes. The PANDA test P4 has provided data about how trapped air released from the drywell later in the transient affects PCCS performance in an adequate manner. The well-defined measurements can serve as an important database for the assessment of thermal hydraulic system analysis codes, especially for conditions that could be met in passively operated advanced reactors, i.e. low pressure and small driving forces. Based on the analysis of the test data, the test acceptance criteria have been met. The test P4 has been successfully completed and the instrument readings were with the permitted ranges. The PCCs showed a favorable and robust performance and a wide margin for decay heat removal from the containment. The PANDA P4 test demonstrated that trapped air, released from the drywell later in the transient, only temporarily and only slightly affected the performance of the passive containment cooling system. The analysis of the results of the RELAPS code showed that the overall behaviour of the test has been calculated quite well with regards to pressure, mass flow rates, and pool boil-down. This accounts both for the pre-test and the post-test simulations. However, due to the one-dimensional, stacked-volume modeling of the PANDA DW, WW, and GDCS vessels, 3D-effects such as in-vessel mixing and recirculation could not be calculated. The post-test MELCOR simulation showed an overall behaviour that is comparable to RELAPS. However, MELCOR calculated almost no air trapping in the PCC tubes that could hinder the steam condensation rate. This resulted in lower calculated

  11. Research on bulk-cargo-port berth assignment based on priority of resource allocation

    Directory of Open Access Journals (Sweden)

    Chunfang Guo

    2013-03-01

    Full Text Available Purpose: The purpose of this paper is to propose a Priority of Resource Allocation model about how to utilize the resources of the port efficiently, through the improvement of traditional ant colony algorithm, the ship-berth matching relation constraint matrix formed by ontology reasoning. Design/methodology/approach: Through questionnaires?Explore factor analysis (EFA and principal component analysis, the authors extract the importance of the goods, the importance of customers, and type of trade as the main factors of the ship operating priority. Then the authors combine berth assignment problem with the improved ant colony algorithm, and use the model to improve ship scheduling quality. Finally, the authors verify the model with physical data in a bulk-cargo-port in China. Findings: Test by the real data of bulk cargo port, it show that ships’ resource using priority and the length of waiting time are consistent; it indicates that the priority of resource allocation play a prominent role in improving ship scheduling quality. Research limitations: The questionnaires is limited in only one port group, more  related Influence factors should be considered to extend the conclusion. Practical implications: The Priority of Resource Allocation model in this paper can be used to improve the efficiency of the dynamic berth assignment. Originality: This paper makes the time of ship in port minimized as the optimization of key indicators and establishes a dynamic berth assignment model based on improved ant colony algorithm and the ontology reasoning model.

  12. Concept design of CFETR superconducting magnet system based on different maintenance ports

    International Nuclear Information System (INIS)

    Zheng, Jinxing; Liu, Xufeng; Song, Yuntao; Wan, Yuanxi; Li, Jiangang; Wu, Sontao; Wan, Baonian; Ye, Minyou; Wei, Jianghua; Xu, Weiwei; Liu, Sumei; Weng, Peide; Lu, Kun; Luo, Zhengping

    2013-01-01

    Highlights: • This article discussed the concept design of the magnet system of CFETR based on different maintenance port cases. • The major and minor radius of plasma is 5.7 m and 1.6 m, and the central magnetic field was designed as 4.5/5.0 T. • The different maintenance ports design have little impact on the design of TF and CS coils’ design, but have certain impact on the PF coils’ design. -- Abstract: CFETR which stands for “China Fusion Engineering Test Reactor” is a new tokamak device. Its magnet system includes the Toroidal Field (TF) winding, Center solenoid winding (CS) and Poloidal Field (PF) winding. The main goal of the project is to build a fusion engineering Tokamak reactor with its fusion power is 50–200 MW and should be self-sufficiency by blanket. In order to ensure the maintenance ports design and maintenance method, this article discussed the concept design of the magnet system based on different maintenance port cases. The paper detailed studied the magnet system of CFETR including the electromagnetic analysis and parameters for TF (CS)PF. Besides, the volt-seconds of ohmic field are presented as detailed as possible in this paper. In addition, the calculations and optimizations of equilibrium field which should guarantee the plasma discharge of single null shape is carried out. The design work reported here illustrates that the present maintenance ports will not have a great impact on the design of the magnet system. The concept design of the magnet system can meet the requirement of the physical target

  13. Application of Game Theory and Uncertainty Theory in Port Competition between Hong Kong Port and Shenzhen Port

    Directory of Open Access Journals (Sweden)

    Thi Minh Hoang Do

    2015-06-01

    Full Text Available This paper unveils the strong competition in container cargo between Hong Kong Port which has been emerging as an international maritime center since the 1970s and Shenzhen Port which has recently gained remarkable achievements in the Pearl River Delta region. Among various competing strategies, the study focuses on the long-term one in which two ports will decide to compete by investing in capacity. The purpose of this research is to examine their decision making process and to suggest future strategic actions in the current situation. Within its scope, only economic profit brought back from the investment is considered. For this reason, an uncertain payoff two-person game model is developed where an uncertain factor of demand is involved. In applying Uncertainty theory (Liu, 2013, the two methods to solve the game are introduced, including uncertain statistics and the expected Nash Equilibrium strategy. The results obtained from this research generate meaningful suggestions for future competition plan for the two selected ports, which conclude that Shenzhen is the dominant port in this long-term strategy. Compared to existing works on the same topic, the paper shows its distinctiveness by studying the latest competitive situation with regard to the uncertain demand in the game model.

  14. Analysis, fabrication, and field test of an advanced embedded throwing electromechanical sensing system

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Zhen; Zhang, Dan [Beijing JiaoTong University, Beijing (China)

    2014-01-15

    Scientific measuring equipment is important in maintaining and further improving the daily training quality of professional athletes. In throwing sports, only kinematic information is usually recorded by several high-speed cameras, whereas the dynamic data are lacking. An advanced embedded throwing system is analyzed, fabricated, and field tested. This throwing system can be used to substitute the normal shot-put that obtains acceleration information from the upper limb when force is applied onto the device. This device has four main parts, namely, a mechanical shell, an embedded sensor, a signal processing circuit, and interface ports. The detailed design, simulation, and prototyping process are introduced in this work. The practical results obtained from the field test and feedback from users prove that the proposed throwing system is efficient for technical training and monitoring. This design provides a unique solution for the modeling and development of non-traditional, electro-mechanical sensing devices.

  15. Thrust Augmented Nozzle for a Hybrid Rocket with a Helical Fuel Port

    Science.gov (United States)

    Marshall, Joel H.

    A thrust augmented nozzle for hybrid rocket systems is investigated. The design lever-ages 3-D additive manufacturing to embed a helical fuel port into the thrust chamber of a hybrid rocket burning gaseous oxygen and ABS plastic as propellants. The helical port significantly increases how quickly the fuel burns, resulting in a fuel-rich exhaust exiting the nozzle. When a secondary gaseous oxygen flow is injected into the nozzle downstream of the throat, all of the remaining unburned fuel in the plume spontaneously ignites. This secondary reaction produces additional high pressure gases that are captured by the nozzle and significantly increases the motor's performance. Secondary injection and combustion allows a high expansion ratio (area of the nozzle exit divided by area of the throat) to be effective at low altitudes where there would normally be significantly flow separation and possibly an embedded shock wave due. The result is a 15 percent increase in produced thrust level with no loss in engine efficiency due to secondary injection. Core flow efficiency was increased significantly. Control tests performed using cylindrical fuel ports with secondary injection, and helical fuel ports without secondary injection did not exhibit this performance increase. Clearly, both the fuel-rich plume and secondary injection are essential features allowing the hybrid thrust augmentation to occur. Techniques for better design optimization are discussed.

  16. Inland Ports in the Republic of Croatia: Approvals for Port Activities instead of Concessions

    Directory of Open Access Journals (Sweden)

    Goran Vojković

    2008-11-01

    Full Text Available According to the 1998 Act on Inland Ports, the right to performall port activities within inland ports of the Republic ofCroatia is given on the basis of concession, obtained throughbidding. It has been noticed in practice that modem businessprocesses and traffic flows are more dynamic than before whenclassic concession relations were created. Also, types andamounts of cargo are changing every couple of years, which isfollowed by quick adjustments, instead of working according torigid and long-term defined decisions and concession contracts.Furthermore, the practice has shown for some activitiesthat the number of port providers (such as ship suppliers,port-agency and freight forwarders should not be limited. Thismeans that the system of a limited number of port providers isimportant only for the activities that require location within aport, as the port area is physically limited. Therefore, the newAct on Navigation and Inland Ports from 2007, whose framehas been completed by sub-law acts during 2008, has replacedthe complex concession system for performing activities in inlandports by a more liberal approval system. On the basis ofthese, higher dynamics of work of port providers is enabled aswell as easier adjustment to market conditions. Furthermore,the main limitation factor that determines the number of portusers becomes the available physical space within a port, whichprovides undisturbed competition, along with larger offer ofport services that do not require that space. It is also importantto point out that the new Act specifically includes distributionand cargo logistics, also processing and improvement of goodsas well as industrial activities including production that enablecomplete economic utilization of port capacities into the existingport activities, thus significantly changing the role of the portitself as a logistic centre.

  17. 40 CFR 63.7322 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Science.gov (United States)

    2010-07-01

    ... appendix A to 40 CFR part 60. (i) Method 1 to select sampling port locations and the number of traverse...) Method 3, 3A, or 3B to determine the dry molecular weight of the stack gas. (iv) Method 4 to determine.... Collect a minimum sample volume of 30 dry standard cubic feet of gas during each test run. Three valid...

  18. Does Refactoring of Test Smells Induce Fixing Flaky Tests?

    NARCIS (Netherlands)

    Palomba, F.; Zaidman, A.E.

    2017-01-01

    Regression testing is a core activity that allows developers to ensure that source code changes do not introduce bugs. An important prerequisite then is that test cases are deterministic. However, this is not always the case as some tests suffer from socalled flakiness. Flaky tests have serious

  19. Benchmark accident scenarios for nuclear powered warship visits to Australian ports

    International Nuclear Information System (INIS)

    Frikken, A.J.

    1996-01-01

    Full text: Port safety arrangements for visits of nuclear powered warships (NPWs) to Australian ports require compliance with a number of Conditions of Entry. One of these Conditions of Entry is the provision of 'an operating safety organisation, competent to produce a suitable radiation monitoring program and able to initiate actions and provide services necessary to safeguard the public in the event of a release of radioactivity following an accident'. The States and Territories which receive NPW visits have the responsibility for this contingency planning, although the Commonwealth provides assistance through the Visiting Ships Panel Nuclear (VSP(N)). The visit of a NPW to an Australian port may only proceed if the VSP(N) is satisfied that the port safety plan has been exercised in sufficient depth to demonstrate its adequacy and efficacy. Emergency exercises are held on a regular basis in Australian ports which have been validated for visits by NPWs to ensure compliance with the Conditions of Entry. Important aspects of these exercises are the procedures for estimating radiation doses to members of the public following an accident, and the process for making decisions on the need for countermeasures based on the results of dose estimates. To exercise these aspects of the emergency response, detailed emergency exercise scenarios, including simulated radiological monitoring data, are required. To date, emergency exercises have usually been based on a severe and highly improbable scenario, termed the Reference Accident, which is used to assess the suitability of ports for visits by NPW's. The repeated adoption of this scenario does not adequately test the flexibility of the emergency plans to cope with all possible accidents, particularly more likely, less severe accidents. At the request of the VSP(N), the Nuclear Safety Bureau has analysed a spectrum of NPW accident scenarios and developed a set of Bench Mark Accident (BMA) scenarios for emergency response

  20. Fuels and materials testing capabilities in Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Baker, R.B.; Chastain, S.A.; Culley, G.E.; Ethridge, J.L.; Lovell, A.J.; Newland, D.J.; Pember, L.A.; Puigh, R.J.; Waltar, A.E.

    1989-01-01

    The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test assembly (FOTA), closed loop in-reactor assembly (CLIRA), and other special fuel assemblies. An interim examination and maintenance cell (FFTF/IEM cell) and other hot cells are used for nondestructive/destructive tests and physical/mechanical properties test of material after irradiation. (N.K.)

  1. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  2. A test matrix sequencer for research test facility automation

    Science.gov (United States)

    Mccartney, Timothy P.; Emery, Edward F.

    1990-01-01

    The hardware and software configuration of a Test Matrix Sequencer, a general purpose test matrix profiler that was developed for research test facility automation at the NASA Lewis Research Center, is described. The system provides set points to controllers and contact closures to data systems during the course of a test. The Test Matrix Sequencer consists of a microprocessor controlled system which is operated from a personal computer. The software program, which is the main element of the overall system is interactive and menu driven with pop-up windows and help screens. Analog and digital input/output channels can be controlled from a personal computer using the software program. The Test Matrix Sequencer provides more efficient use of aeronautics test facilities by automating repetitive tasks that were once done manually.

  3. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  4. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  5. Effectiveness of a Barge-Based Ballast Water Treatment System for Multi-Terminal Ports

    Directory of Open Access Journals (Sweden)

    Lovro Maglić

    2015-10-01

    Full Text Available The paper presents outcomes of the discrete event simulation of the ballast water management in a multi-terminal port. The simulation includes ship’s manoeuvring, cargo and ballast operations and a barge-based ballast water treatment system operating within all terminal areas. The barge-based ballast water treatment system is used by ships unable to use their own equipment, not equipped with an appropriate ballast treatment system or non-compliant with the Ballast Water Management (BWM Convention 2004 for whatever reason. The main goal is to estimate the productivity and cost effectiveness of such systems as an option to support ships not able to comply with the BWM Convention, once it enters into force. The model was built and tested in Arena simulation software. Process parameters are based on real traffic data for the port of Rijeka. The results indicate that barge-based ballast treatment facility will be heavily underutilized, and that such systems are cost-effective only in ports where large volumes of ballast water need to be delivered to shore treatment systems.

  6. 360 PORT MDA - A Strategy to Improve Port Security

    Science.gov (United States)

    2006-09-01

    Participating Agencies (After: Executive Briefing..........................27 Table 6. Designated Joint Operations Center Participants (From: SAFE...Investigations CGIP Coast Guard Intelligence Program CHOC Charleston Harbor Operations Center CIO Command Intelligence Officer CMT Combating Maritime... EXECUTIVE SUMMARY Ports are critical to our economy and national security. Key hubs in the international trade network, U.S. ports accounted for more than

  7. Operational test report for LERF Basin 242AL-44 integrity test

    International Nuclear Information System (INIS)

    Galioto, T.M.

    1994-01-01

    This operational test report documents the results of LERF operational testing per operational test procedure (OTP) TFPE-WP-0231, ''LERF Basin Integrity Testing.'' The primary purpose of the OTP was to resolve test exceptions generated as a result of TFPE-WP-0184. The TOP was prepared and performed in accordance with WHC-SD-534-OTP-002, ''Operational Test Plan for the 242-A Evaporator Upgrades and the Liquid Effluent Retention Facility.'' WHC-S-086, ''Specification for Operational Testing of the Liquid Effluent Retention Facility, Basin Integrity Testing,'' identified the test requirements and acceptance criteria. The completed, signed-off test procedure is contained in Appendix A. The test log is contained in Appendix B. Section 2.1 describes all the test exceptions written during performance of the Operational Test Procedure. The test revisions generated during the testing are discussed in Section 2.2. The dispositioned test exception forms are contained in Appendix C

  8. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  9. Test Anxiety, Computer-Adaptive Testing and the Common Core

    Science.gov (United States)

    Colwell, Nicole Makas

    2013-01-01

    This paper highlights the current findings and issues regarding the role of computer-adaptive testing in test anxiety. The computer-adaptive test (CAT) proposed by one of the Common Core consortia brings these issues to the forefront. Research has long indicated that test anxiety impairs student performance. More recent research indicates that…

  10. TESTING TESTS ON ACTIVE GALACTIC NUCLEI MICROVARIABILITY

    International Nuclear Information System (INIS)

    De Diego, Jose A.

    2010-01-01

    Literature on optical and infrared microvariability in active galactic nuclei (AGNs) reflects a diversity of statistical tests and strategies to detect tiny variations in the light curves of these sources. Comparison between the results obtained using different methodologies is difficult, and the pros and cons of each statistical method are often badly understood or even ignored. Even worse, improperly tested methodologies are becoming more and more common, and biased results may be misleading with regard to the origin of the AGN microvariability. This paper intends to point future research on AGN microvariability toward the use of powerful and well-tested statistical methodologies, providing a reference for choosing the best strategy to obtain unbiased results. Light curves monitoring has been simulated for quasars and for reference and comparison stars. Changes for the quasar light curves include both Gaussian fluctuations and linear variations. Simulated light curves have been analyzed using χ 2 tests, F tests for variances, one-way analyses of variance and C-statistics. Statistical Type I and Type II errors, which indicate the robustness and the power of the tests, have been obtained in each case. One-way analyses of variance and χ 2 prove to be powerful and robust estimators for microvariations, while the C-statistic is not a reliable methodology and its use should be avoided.

  11. Mononucleosis spot test

    Science.gov (United States)

    Monospot test; Heterophile antibody test; Heterophile agglutination test; Paul-Bunnell test; Forssman antibody test ... The mononucleosis spot test is done when symptoms of mononucleosis are ... Fatigue Fever Large spleen (possibly) Sore throat Tender ...

  12. Automated test data generation for branch testing using incremental

    Indian Academy of Sciences (India)

    Cost of software testing can be reduced by automated test data generation to find a minimal set of data that has maximum coverage. Search-based software testing (SBST) is one of the techniques recently used for automated testing task. SBST makes use of control flow graph (CFG) and meta-heuristic search algorithms to ...

  13. BWR Full Integral Simulation Test (FIST). Phase I test results

    International Nuclear Information System (INIS)

    Hwang, W.S.; Alamgir, M.; Sutherland, W.A.

    1984-09-01

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report

  14. Port Stakeholder Summit - April 2014

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  15. Integrated Test and Evaluation (ITE) Flight Test Series 4

    Science.gov (United States)

    Marston, Michael

    2016-01-01

    The integrated Flight Test 4 (FT4) will gather data for the UAS researchers Sense and Avoid systems (referred to as Detect and Avoid in the RTCA SC 228 ToR) algorithms and pilot displays for candidate UAS systems in a relevant environment. The technical goals of FT4 are to: 1) perform end-to-end traffic encounter test of pilot guidance generated by DAA algorithms; 2) collect data to inform the initial Minimum Operational Performance Standards (MOPS) for Detect and Avoid systems. FT4 objectives and test infrastructure builds from previous UAS project simulations and flight tests. NASA Ames (ARC), NASA Armstrong (AFRC), and NASA Langley (LaRC) Research Centers will share responsibility for conducting the tests, each providing a test lab and critical functionality. UAS-NAS project support and participation on the 2014 flight test of ACAS Xu and DAA Self Separation (SS) significantly contributed to building up infrastructure and procedures for FT3 as well. The DAA Scripted flight test (FT4) will be conducted out of NASA Armstrong over an eight-week period beginning in April 2016.

  16. AST Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/asttest.html AST Test To use the sharing features on this page, please enable JavaScript. What is an AST Test? AST (aspartate aminotransferase) is an enzyme that is ...

  17. Chlamydia Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/chlamydiatest.html Chlamydia Test To use the sharing features on this page, please enable JavaScript. What is a Chlamydia Test? Chlamydia is one of the most common sexually ...

  18. Lipase Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/lipasetest.html Lipase Test To use the sharing features on this page, please enable JavaScript. What is a lipase test? Lipase is a type of protein made by ...

  19. Cortisol Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/cortisoltest.html Cortisol Test To use the sharing features on this page, please enable JavaScript. What is a Cortisol Test? Cortisol is a hormone that affects almost every ...

  20. Nuclear Fuel Test Rod Fabrication for Data Acquisition Test

    International Nuclear Information System (INIS)

    Joung, Chang-Young; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho

    2014-01-01

    A nuclear fuel test rod must be fabricated with precise welding and assembly technologies, and confirmed for their soundness. Recently, we have developed various kinds of processing systems such as an orbital TIG welding system, a fiber laser welding system, an automated drilling system and a helium leak analyzer, which are able to fabricate the nuclear fuel test rods and rigs, and keep inspection systems to confirm the soundness of the nuclear fuel test rods and rids. The orbital TIG welding system can be used with two kinds of welding methods. One can perform the round welding for end-caps of a nuclear fuel test rod by an orbital head mounted in a low-pressure chamber. The other can do spot welding for a pin-hole of a nuclear fuel test rod in a high-pressure chamber to fill up helium gas of high pressure. The fiber laser welding system can weld cylindrical and 3 axis samples such as parts of a nuclear fuel test rod and instrumentation sensors which is moved by an index chuck and a 3 axis (X, Y, Z) servo stage controlled by the CNC program. To measure the real-time temperature change at the center of the nuclear fuel during the irradiation test, a thermocouple should be instrumented at that position. Therefore, a hole needs to be made at the center of fuel pellet to instrument the thermocouple. An automated drilling system can drill a fine hole into a fuel pellet without changing tools or breaking the work-piece. The helium leak analyzer (ASM-380 model of DEIXEN Co.) can check the leak of the nuclear fuel test rod filled with helium gas. This paper describes not only the assembly and fabrication methods used by the process systems, but also the results of the data acquisition test for the nuclear fuel test rod. A nuclear fuel test rod for the data acquisition test was fabricated using the welding and assembling echnologies acquired from previous tests

  1. Nuclear Fuel Test Rod Fabrication for Data Acquisition Test

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    A nuclear fuel test rod must be fabricated with precise welding and assembly technologies, and confirmed for their soundness. Recently, we have developed various kinds of processing systems such as an orbital TIG welding system, a fiber laser welding system, an automated drilling system and a helium leak analyzer, which are able to fabricate the nuclear fuel test rods and rigs, and keep inspection systems to confirm the soundness of the nuclear fuel test rods and rids. The orbital TIG welding system can be used with two kinds of welding methods. One can perform the round welding for end-caps of a nuclear fuel test rod by an orbital head mounted in a low-pressure chamber. The other can do spot welding for a pin-hole of a nuclear fuel test rod in a high-pressure chamber to fill up helium gas of high pressure. The fiber laser welding system can weld cylindrical and 3 axis samples such as parts of a nuclear fuel test rod and instrumentation sensors which is moved by an index chuck and a 3 axis (X, Y, Z) servo stage controlled by the CNC program. To measure the real-time temperature change at the center of the nuclear fuel during the irradiation test, a thermocouple should be instrumented at that position. Therefore, a hole needs to be made at the center of fuel pellet to instrument the thermocouple. An automated drilling system can drill a fine hole into a fuel pellet without changing tools or breaking the work-piece. The helium leak analyzer (ASM-380 model of DEIXEN Co.) can check the leak of the nuclear fuel test rod filled with helium gas. This paper describes not only the assembly and fabrication methods used by the process systems, but also the results of the data acquisition test for the nuclear fuel test rod. A nuclear fuel test rod for the data acquisition test was fabricated using the welding and assembling echnologies acquired from previous tests.

  2. Preliminary Design Progress of the HCCR TBM for ITER testing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Won; Park, Sung Dae; Kim, Dong Jun; Jin, Hyung Gon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ahn, Mu-Young [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Korea has designed a helium cooled ceramic reflector (HCCR) test blanket module (TBM) including the TBM-shield, which is called the TBM-set, to be tested in ITER, a Nuclear Facility INB-174. Through the conceptual design review (CDR), its design integrity was successfully demonstrated at the conceptual design level at various loads. After CD approval, preliminary design (PD) was started and the progress is introduced in the present study. After PD review and approval, final design and then fabrication will be started. The main purpose of PD is to design the TBM-set according to the fabrication aspect and more detailed design for interfaces with ITER machine, such as installed TBM port plug and frame. With these considering, PD of TBM-set was started. PD for HCCR TBM has been performed (so far v0.24) from the CD model. FW, BZ, SW, TES/NAS, BM, and connecting support design were performed through the analyses, if necessary. The manufacturability was the main concern for PD model development. Thermal hydraulic analysis will be performed to evaluate the temperature and pressure drop in TBM-set. The structural integrity of TBM-set will be confirmed with combined various loads condition.

  3. AZ-101 Mixer Pump Test Qualification Test Procedures (QTP)

    International Nuclear Information System (INIS)

    THOMAS, W.K.

    2000-01-01

    Describes the Qualification test procedure for the AZ-101 Mixer Pump Data Acquisition System (DAS). The purpose of this Qualification Test Procedure (QTP) is to confirm that the AZ-101 Mixer Pump System has been properly programmed and hardware configured correctly. This QTP will test the software setpoints for the alarms and also check the wiring configuration from the SIMcart to the HMI. An Acceptance Test Procedure (ATP), similar to this QTP will be performed to test field devices and connections from the field

  4. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients.

    Science.gov (United States)

    Wang, Ting-Yao; Lee, Kuan-Der; Chen, Ping-Tsung; Chen, Min-Chi; Chen, Yi-Yang; Huang, Cih-En; Kuan, Feng-Che; Chen, Chih-Cheng; Lu, Chang Hsien

    2015-11-01

    Cytotoxic chemotherapy via central venous access ports is an important part of the standard treatment for most cancers, but it is accompanied with the risk of infections. This study aimed to analyze the incidence and risk factors for central venous access port-related infection (CPI) among Chinese patients receiving cytotoxic chemotherapy. Between January 1, 2002 and December 31, 2005 a total of 1391 cancer patients with 1449 totally implantable central venous access ports were evaluated. The log-rank test and Cox proportional hazards model were used for the analyses of risk factors. The overall CPI incidence rate was 0.21 per 1000 catheter-days. Hematological malignancies and head and neck cancer were associated with an increased risk of CPI (hazard ratio 4.00 and 4.11, respectively, both p risk of infection than for patients in a nonadjuvant setting (p ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings. Copyright © 2015. Published by Elsevier B.V.

  5. Light Duty Utility Arm system pre-operational (cold test) test plan

    International Nuclear Information System (INIS)

    Bennett, K.L.

    1995-01-01

    The Light Duty Utility (LDUA) Cold Test Facility, located in the Hanford 400 Area, will be used to support cold testing (pre- operational tests) of LDUA subsystems. Pre-operational testing is composed of subsystem development testing and rework activities, and integrated system qualification testing. Qualification testing will be conducted once development work is complete and documentation is under configuration control. Operational (hot) testing of the LDUA system will follow the testing covered in this plan and will be covered in a separate test plan

  6. An Analysis of Port Service Quality and Customer Satisfaction: The Case of Korean Container Ports

    Directory of Open Access Journals (Sweden)

    Gi Tae Yeo

    2015-12-01

    Full Text Available Ports play a critical role in the economy of many countries and regions. Failure or unreliability of port services can significantly influence port customers—shipping lines and cargo owners—and result in their dissatisfaction. However, what constitutes port service quality (PSQ and its influence on the satisfaction of port customers has not been well investigated in the literature. Therefore, this study investigates the concept of PSQ and its influence on customer satisfaction in the case of Korean container ports. Following a literature review, a conceptual model of PSQ and its influence on customer satisfaction is proposed. The model was validated through a survey of 313 members of the Korean Port Logistics Association (KPLA. Partial least squares structural equation modeling (PLS-SEM was conducted to confirm the PSQ dimensions and to examine their relationship with customer satisfaction using SmartPLS 3.2.1 software. PSQ is found to be a five-factor construct, and its management, and image and social responsibility factors have significant positive effects on customer satisfaction. In addition to its academic contribution, this study also contributes to management practices because port managers can use the PSQ scale to measure their customers’ satisfaction and justify investments in the quality management of port services.

  7. Coccidioides precipitin test

    Science.gov (United States)

    Coccidioidomycosis antibody test; Coccidioides blood test; Valley fever blood test ... There is no special preparation for the test. ... The precipitin test is one of several tests that can be done to determine if you are infected with coccidioides, which ...

  8. Syphilis Test

    Science.gov (United States)

    ... Genetic Tests for Targeted Cancer Therapy Glucose Tests Gonorrhea Testing Gram Stain Growth Hormone Haptoglobin hCG Pregnancy ... treated for another sexually transmitted disease , such as gonorrhea Is pregnant, during the first prenatal visit and ...

  9. New Graphical Methods and Test Statistics for Testing Composite Normality

    Directory of Open Access Journals (Sweden)

    Marc S. Paolella

    2015-07-01

    Full Text Available Several graphical methods for testing univariate composite normality from an i.i.d. sample are presented. They are endowed with correct simultaneous error bounds and yield size-correct tests. As all are based on the empirical CDF, they are also consistent for all alternatives. For one test, called the modified stabilized probability test, or MSP, a highly simplified computational method is derived, which delivers the test statistic and also a highly accurate p-value approximation, essentially instantaneously. The MSP test is demonstrated to have higher power against asymmetric alternatives than the well-known and powerful Jarque-Bera test. A further size-correct test, based on combining two test statistics, is shown to have yet higher power. The methodology employed is fully general and can be applied to any i.i.d. univariate continuous distribution setting.

  10. Concerning background from calorimeter ports

    International Nuclear Information System (INIS)

    Digiacomo, N.J.

    1985-01-01

    Any detector system viewing a port or slit in a calorimeter wall will see, in addition to the primary particles of interest, a background of charged and neutral particles and photons generated by scattering from the port walls and by leakage from incompletely contained primary particle showers in the calorimeter near the port. The signal to noise ratio attainable outside the port is a complex function of the primary source spectrum, the calorimeter and port design and, of course, the nature and acceptance of the detector system that views the port. Rather than making general statements about the overall suitability (or lack thereof) of calorimeter ports, we offer here a specific example based on the external spectrometer and slit of the NA34 experiment. This combination of slit and spectrometer is designed for fixed-target work, so that the primary particle momentum spectrum contains higher momentum particles than expected in a heavy ion colliding beam environment. The results are, nevertheless, quite relevant for the collider case

  11. Nuclear stress test

    Science.gov (United States)

    ... Persantine stress test; Thallium stress test; Stress test - nuclear; Adenosine stress test; Regadenoson stress test; CAD - nuclear stress; Coronary artery disease - nuclear stress; Angina - nuclear ...

  12. Pharmacogenomic Testing

    Science.gov (United States)

    ... your family Plan for the future Insurance and financial planning Transition for children Emergency preparedness Testing & Services Testing ... Support Genetic Disease Information Find a Support Group Financial Planning Who Should I Tell? Genetic Testing & Counseling Compensation ...

  13. Predictive Testing

    Science.gov (United States)

    ... your family Plan for the future Insurance and financial planning Transition for children Emergency preparedness Testing & Services Testing ... Support Genetic Disease Information Find a Support Group Financial Planning Who Should I Tell? Genetic Testing & Counseling Compensation ...

  14. Nationale Test

    DEFF Research Database (Denmark)

    2009-01-01

    Hvad er egentlig formålet med de nationale test? Bliver eleverne klogere af at blive testet? Og er der en sammenhæng mellem bandekrig og nationale test? Fysisk medie: dpu.dk/tv......Hvad er egentlig formålet med de nationale test? Bliver eleverne klogere af at blive testet? Og er der en sammenhæng mellem bandekrig og nationale test? Fysisk medie: dpu.dk/tv...

  15. A computer-controlled automated test system for fatigue and fracture testing

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Alexander, D.J.; Swain, R.L.; Hutton, J.T.; Thomas, D.L.

    1989-01-01

    A computer-controlled system consisting of a servohydraulic test machine, an in-house designed test controller, and a desktop computer has been developed for performing automated fracture toughness and fatigue crack growth testing both in the laboratory and in hot cells for remote testing of irradiated specimens. Both unloading compliance and dc-potential drop can be used to monitor crack growth. The test controller includes a dc-current supply programmer, a function generator for driving the servohydraulic test machine to required test outputs, five measurement channels (each consisting of low-pass filter, track/hold amplifier, and 16-bit analog-to-digital converter), and digital logic for various control and data multiplexing functions. The test controller connects to the computer via a 16-bit wide photo-isolated bidirectional bus. The computer, a Hewlett-Packard series 200/300, inputs specimen and test parameters from the operator, configures the test controller, stores test data from the test controller in memory, does preliminary analysis during the test, and records sensor calibrations, specimen and test parameters, and test data on flexible diskette for later recall and analysis with measured initial and final crack length information. During the test, the operator can change test parameters as necessary. 24 refs., 6 figs

  16. Geometric and Optic Characterization of a Hemispherical Dome Port for Underwater Photogrammetry

    Directory of Open Access Journals (Sweden)

    Fabio Menna

    2016-01-01

    Full Text Available The popularity of automatic photogrammetric techniques has promoted many experiments in underwater scenarios leading to quite impressive visual results, even by non-experts. Despite these achievements, a deep understanding of camera and lens behaviors as well as optical phenomena involved in underwater operations is fundamental to better plan field campaigns and anticipate the achievable results. The paper presents a geometric investigation of a consumer grade underwater camera housing, manufactured by NiMAR and equipped with a 7′′ dome port. After a review of flat and dome ports, the work analyzes, using simulations and real experiments, the main optical phenomena involved when operating a camera underwater. Specific aspects which deal with photogrammetric acquisitions are considered with some tests in laboratory and in a swimming pool. Results and considerations are shown and commented.

  17. Development and test of prototype components for ITER; Entwicklung und Test von Prototypkomponenten fuer ITER

    Energy Technology Data Exchange (ETDEWEB)

    Biel, Wolfgang; Behr, Wilfried; Castano-Bardawil, David; and others

    2015-08-15

    The scientific program of the project is divided into the following partial projects: (1.) ITER Diagnostic Port Plug for the charge-exchange spectroscopy (CXRS) with the subthemes: (a) Development of prototypes for critical mechanical components, (b) development of a roboter for the laser welding of vacuum seals and pipings at the Port Plug, (c) mirror studies, (d) CXRS prototype spectrometer, (2.) ITER tritium retention diagnostics (TR), (3.) ITER disruption mitigation ventile (DMV).

  18. Non-Price Competition in the Port Sector: A Case Study of Ports in Turkey

    OpenAIRE

    Soner Esmer; Hong-Oanh Nguyen, Ph.D.; Yapa Mahinda Bandara, Ph.D.; Kazim Yeni, Ph.D.

    2016-01-01

    Although the port sector has been facing increasing competition, there is limited research on how ports compete using non-price competition strategies. There are a few studies on non-price competition in the port sector. However they mainly focus on the marketing aspect. This paper seeks to fill this gap in the literature, especially from a combined marketing-economic perspective. Especially the paper's main objective is to identify the determinants of non-price competition in the port sector...

  19. Heart failure - tests

    Science.gov (United States)

    CHF - tests; Congestive heart failure - tests; Cardiomyopathy - tests; HF - tests ... the best test to: Identify which type of heart failure (systolic, diastolic, valvular) Monitor your heart failure and ...

  20. 5-HIAA Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  1. Uric Acid Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  2. Direct Antiglobulin Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  3. CK-MB Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  4. Understanding Your Tests

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  5. Myasthenia Gravis Tests

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  6. The comparison of the unit test tools JUnit and TestNG

    OpenAIRE

    Šarkanj, Aleš

    2011-01-01

    Testing holds an important role in developing software. It is a process ensuring software works as expected. An important part of testing is unit testing as the basic testing level. The purpose of this thesis is comparing JUnit and TestNG, two of the most popular unit testing tools in Java. In the first part we will present testing and its purpose within software development. We will also present the basic terminology and levels of testing. Further on the area of unit testing will be pr...

  7. Flow analysis and port optimization of geRotor pump using commercial CFD code

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Jo; Seong, Seung Hak; Yoon, Soon Hyun [Pusan National Univ., Pusan (Korea, Republic of)

    2005-07-01

    GeRotor pump is widely used in the automotive industry for fuel lift, injection, engine oil lubrication, and also in transmission systems. The CFD study of the pump, which is characterized by transient flow with moving rotor boundaries, has been performed to obtain the most optimum shape of the inlet/outlet port of the pump. Various shapes of the port have been tested to investigate how they affect flow rates and fluctuations. Based on the parametric study, an optimum shape has been determined for the maximum flow rate and minimum fluctuations. The result has been confirmed by experiments. For the optimization, Taguchi method has been adapted. The groove shape has been found to be the most important factor among the selected several parameters related to flow rate and fluctuations.

  8. The test-retest reliability and criterion validity of a high-intensity, netball-specific circuit test: The Net-Test.

    Science.gov (United States)

    Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T

    2018-04-12

    To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (Test possessed low CV and significant (pTest possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. An innovative approach for testing bioinformatics programs using metamorphic testing

    Directory of Open Access Journals (Sweden)

    Liu Huai

    2009-01-01

    Full Text Available Abstract Background Recent advances in experimental and computational technologies have fueled the development of many sophisticated bioinformatics programs. The correctness of such programs is crucial as incorrectly computed results may lead to wrong biological conclusion or misguide downstream experimentation. Common software testing procedures involve executing the target program with a set of test inputs and then verifying the correctness of the test outputs. However, due to the complexity of many bioinformatics programs, it is often difficult to verify the correctness of the test outputs. Therefore our ability to perform systematic software testing is greatly hindered. Results We propose to use a novel software testing technique, metamorphic testing (MT, to test a range of bioinformatics programs. Instead of requiring a mechanism to verify whether an individual test output is correct, the MT technique verifies whether a pair of test outputs conform to a set of domain specific properties, called metamorphic relations (MRs, thus greatly increases the number and variety of test cases that can be applied. To demonstrate how MT is used in practice, we applied MT to test two open-source bioinformatics programs, namely GNLab and SeqMap. In particular we show that MT is simple to implement, and is effective in detecting faults in a real-life program and some artificially fault-seeded programs. Further, we discuss how MT can be applied to test programs from various domains of bioinformatics. Conclusion This paper describes the application of a simple, effective and automated technique to systematically test a range of bioinformatics programs. We show how MT can be implemented in practice through two real-life case studies. Since many bioinformatics programs, particularly those for large scale simulation and data analysis, are hard to test systematically, their developers may benefit from using MT as part of the testing strategy. Therefore our work

  10. Convergent validity test, construct validity test and external validity test of the David Liberman algorithm

    Directory of Open Access Journals (Sweden)

    David Maldavsky

    2013-08-01

    Full Text Available The author first exposes a complement of a previous test about convergent validity, then a construct validity test and finally an external validity test of the David Liberman algorithm.  The first part of the paper focused on a complementary aspect, the differential sensitivity of the DLA 1 in an external comparison (to other methods, and 2 in an internal comparison (between two ways of using the same method, the DLA.  The construct validity test exposes the concepts underlined to DLA, their operationalization and some corrections emerging from several empirical studies we carried out.  The external validity test examines the possibility of using the investigation of a single case and its relation with the investigation of a more extended sample.

  11. Parametric Sensitivity Tests- European PEM Fuel Cell Stack Test Procedures

    DEFF Research Database (Denmark)

    Araya, Samuel Simon; Andreasen, Søren Juhl; Kær, Søren Knudsen

    2014-01-01

    performed based on test procedures proposed by a European project, Stack-Test. The sensitivity of a Nafion-based low temperature PEMFC stack’s performance to parametric changes was the main objective of the tests. Four crucial parameters for fuel cell operation were chosen; relative humidity, temperature......As fuel cells are increasingly commercialized for various applications, harmonized and industry-relevant test procedures are necessary to benchmark tests and to ensure comparability of stack performance results from different parties. This paper reports the results of parametric sensitivity tests......, pressure, and stoichiometry at varying current density. Furthermore, procedures for polarization curve recording were also tested both in ascending and descending current directions....

  12. Analysing Test-Takers’ Views on a Computer-Based Speaking Test

    Directory of Open Access Journals (Sweden)

    Marian Amengual-Pizarro

    2017-11-01

    Full Text Available This study examines test-takers’ views on a computer-delivered speaking test in order to investigate the aspects they consider most relevant in technology-based oral assessment, and to explore the main advantages and disadvantages computer-based tests may offer as compared to face-to-face speaking tests. A small-scale open questionnaire was administered to 80 test-takers who took the APTIS speaking test at the Universidad de Alcalá in April 2016. Results reveal that examinees believe computer-based tests provide a valid measure of oral competence in English and are considered to be an adequate method for the assessment of speaking. Interestingly, the data suggest that personal characteristics of test-takers seem to play a key role in deciding upon the most suitable and reliable delivery mode.

  13. Heavy Metal Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/heavymetalbloodtest.html Heavy Metal Blood Test To use the sharing features ... this page, please enable JavaScript. What is a Heavy Metal Blood Test? A heavy metal blood test ...

  14. Lipoprotein (a) Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/lipoproteinabloodtest.html Lipoprotein (a) Blood Test To use the sharing features ... this page, please enable JavaScript. What is a Lipoprotein (a) Blood Test? A lipoprotein (a) test measures ...

  15. Dynamism Patterns of Western Mediterranean Cruise Ports and the Coopetition Relationships Between Major Cruise Ports

    Directory of Open Access Journals (Sweden)

    Esteve-Perez Jeronimo

    2018-03-01

    Full Text Available The Mediterranean Sea has seen an increase of ports hosting cruise ships during the first fifteen years of the 21st century. The increase in cruise ship presence in Mediterranean ports is associated with the dynamism of cruise traffic in recent years, with an average annual growth of 7.45% for cruise passengers worldwide during the period of 1990-2015. Cruise traffic is a maritime business that is primarily composed of two elements, maritime affairs and tourism. This article focuses on the maritime component. With the growth of the cruise industry, cruise lines have been forced to seek new ports to meet demand in an attempt to create differentiated products based on the ports that compose the itinerary. The itinerary system of cruise traffic makes the cruise ports depend on one another to design an itinerary. This feature results in both complex geographic relationships in the design of a cruise itinerary and complex competitive/cooperative relationships between ports. The aim of this article is to present the hierarchic picture of a sample of 29 cruise ports in the Western Mediterranean region during the period of 2000-2015. To achieve this goal, a port size classification is proposed and a shift-share analysis at the inter- and intra-group size level is applied. Moreover, concentration measures are used to determine the changes in the levels of market concentration. Furthermore, a dynamic model is proposed to determine the competitive or cooperative relationships between cruise ports. The proposed model is applied to the largest ports with data from the 2001-2015 period.

  16. Acute aquatic toxicity of western juniper (Juniperus occidentalis) foliage and Port Orford cedar (Chamaecyparis lawsoniana) heartwood oils.

    Science.gov (United States)

    Duringer, Jennifer M; Swan, Laurence R; Walker, Douglas B; Craig, A Morrie

    2010-11-01

    Recently, interest has developed for using essential oils from Western juniper (Juniperus occidentalis) foliage and Port Orford cedar (Chamaecyparis lawsoniana) heartwood in commercial products such as pest repellents and cosmetics. In order to gauge the relative toxicological risk that these oils pose to freshwater and marine organisms, the acute aquatic toxicity of these oils was evaluated using OPPTS guidelines to the cladoceran Daphnia magna, the rainbow trout Oncorhynchus mykiss and the green alga Selenastrum capricornutum. For western juniper foliage oil, no toxicity was exhibited toward D. magna or O. mykiss, even at 5.0 mg/L (the highest concentration tested and limit of solubility). For toxicity to S. capricornutum using algal cell density, the 72 and 96 h EC50 value was 1.7 mg/L and the no observable effect concentration (NOEC) was 0.63 mg/L. For Port Orford cedar heartwood oil, no toxicity was exhibited toward O. mykiss or S. capricornutum, even at 5.0 mg/L (the highest concentration tested and limit of solubility). The 48-h D. magna EC50 value was 1.9 mg/L; the NOEC values for algal cell density were 1.25 mg/L (72 h) and 0.63 mg/L (96 h). In summary, this study shows that western juniper foliage and Port Orford cedar heartwood oils demonstrate little to no risk to aquatic organisms.

  17. HYBRID DATA APPROACH FOR SELECTING EFFECTIVE TEST CASES DURING THE REGRESSION TESTING

    OpenAIRE

    Mohan, M.; Shrimali, Tarun

    2017-01-01

    In the software industry, software testing becomes more important in the entire software development life cycle. Software testing is one of the fundamental components of software quality assurances. Software Testing Life Cycle (STLC)is a process involved in testing the complete software, which includes Regression Testing, Unit Testing, Smoke Testing, Integration Testing, Interface Testing, System Testing & etc. In the STLC of Regression testing, test case selection is one of the most importan...

  18. Anion Gap Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... https://medlineplus.gov/labtests/aniongapbloodtest.html Anion Gap Blood Test To use the sharing features on this page, please enable JavaScript. What is an Anion Gap Blood Test? An anion gap blood test is a way ...

  19. Testing experience with fast flux test facility

    International Nuclear Information System (INIS)

    Noordhoff, B.H.; McGough, C.B.; Nolan, J.E.

    1975-01-01

    Early FFTF project planning emphasized partial and full-scale testing of major reactor and plant prototype components under expected environmental conditions, excluding radiation fields. Confirmation of component performance during FFTF service was considered essential before actual FFTF startup, to provide increased assurance against FFTF startup delays or operational difficulties and downtime. Several new sodium facilities were constructed, and confirmation tests on the prototype components are now in progress. Test conditions and results to date are reported for the primary pump, intermediate heat exchanger, sodium-to-air dump heat exchanger, large and small sodium valves, purification cold trap, in-vessel handling machine, instrument tree, core restraint, control rod system, low-level flux monitor, closed loop ex-vessel machine, refueling equipment, and selected maintenance equipment. The significance and contribution of these tests to the FFTF and Liquid Metal Fast Breeder Reactor (LMFBR) program are summarized. (U.S.)

  20. The hardness test: a real mechanical test

    International Nuclear Information System (INIS)

    Rezakhanlou, R.

    1993-02-01

    During the service life, the mechanical properties of the PWR components change. It is necessary to determine precisely this evolution, but it is not always possible to draw a sample with the adequate size for the characterization. For this latter case we intend to calculate the stress-strain curve of a material from a hardness test results, because it is appropriate for testing on site and do not need any particular sample shape. This paper is the first bibliographical part of a larger study on the relation between the values measured during a hardness test (applied load, indentation diameter) and the mechanical properties of a solid obtained by a traction test. We have treated the problem within the general setting of two solids in contact. Thus, we expose general elastic, elasto-plastic and plastic models describing the indentation of a solid by a rigid indenter

  1. Drug Testing

    Science.gov (United States)

    ... testing, substance abuse testing, toxicology screen, tox screen, sports doping tests What is it used for? Drug screening is used to find out whether or not a person has taken a certain drug or drugs. It ... Sports organizations. Professional and collegiate athletes usually need to ...

  2. HIV Testing

    Science.gov (United States)

    ... Abroad Treatment Basic Statistics Get Tested Find an HIV testing site near you. Enter ZIP code or city Follow HIV/AIDS CDC HIV CDC HIV/AIDS See RSS | ... All Collapse All Should I get tested for HIV? CDC recommends that everyone between the ages of ...

  3. Testing power-law cross-correlations: Rescaled covariance test

    Czech Academy of Sciences Publication Activity Database

    Krištoufek, Ladislav

    2013-01-01

    Roč. 86, č. 10 (2013), 418-1-418-15 ISSN 1434-6028 R&D Projects: GA ČR GA402/09/0965 Institutional support: RVO:67985556 Keywords : power-law cross-correlations * testing * long-term memory Subject RIV: AH - Economics Impact factor: 1.463, year: 2013 http://library.utia.cas.cz/separaty/2013/E/kristoufek-testing power-law cross-correlations rescaled covariance test.pdf

  4. Ethnic Comparisons in HIV Testing Attitudes, HIV Testing, and Predictors of HIV Testing Among Black and White College Students.

    Science.gov (United States)

    Moore, Melanie P; Javier, Sarah J; Abrams, Jasmine A; McGann, Amanda Wattenmaker; Belgrave, Faye Z

    2017-08-01

    This study's primary aim was to examine ethnic differences in predictors of HIV testing among Black and White college students. We also examined ethnic differences in sexual risk behaviors and attitudes toward the importance of HIV testing. An analytic sample of 126 Black and 617 White undergraduatestudents aged 18-24 were analyzed for a subset of responses on the American College Health Association-National College Health Assessment II (ACHA-NCHA II) (2012) pertaining to HIV testing, attitudes about the importance of HIV testing, and sexual risk behaviors. Predictors of HIV testing behavior were analyzed using logistic regression. t tests and chi-square tests were performed to access differences in HIV test history, testing attitudes, and sexual risk behaviors. Black students had more positive attitudes toward testing and were more likely to have been tested for HIV compared to White students. A greater number of sexual partners and more positive HIV testing attitudes were significant predictors of HIV testing among White students, whereas relationship status predicted testing among Black students. Older age and history of ever having sex were significant predictors of HIV testing for both groups. There were no significant differences between groups in number of sexual partners or self-reports in history of sexual experience (oral, vaginal, or anal). Factors that influence HIV testing may differ across racial/ethnic groups. Findings support the need to consider racial/ethnic differences in predictors of HIV testing during the development and tailoring of HIV testing prevention initiatives targeting college students.

  5. LOBI test BT-15/BT-16 pre-test calculation

    International Nuclear Information System (INIS)

    Holmes, B.J.

    1991-03-01

    LOBI is a higher pressure, electrically heated integral system facility simulating a KWU 1300 MW PWR scaled 1:712 by volume, although full scale has been maintained in the vertical direction. In order to complete the test programme before the facility is closed in 1991 a number of tests have been performed in tandem, where the test procedures were compatible. BT-15/BT-16 is one such composite test. In their original form both tests BT-15 and BT-16 simulated a loss of main feedwater transient with delayed auxiliary feedwater injection, with the pumps running in BT-15 and tripped in BT-16. The aim of each test was to investigate the loss of primary/secondary heat transfer as the steam generator secondary sides boiled down, and the subsequent recovery of heat transfer as the auxiliary feedwater was tripped on. Due to a re-scheduling of the test programme there was insufficient time to perform sensitivity studies and so only one, base case, calculation is presented. (author)

  6. Case Studies: Improving Environmental Performance and Economic Prosperity at Ports and in Near-Port Communities

    Science.gov (United States)

    Case Study links for improving environmental performance and economic prosperity at ports and in near-port communities. Case studies on equipment upgrades, jobs and benefits, land use and transportation, port-community engagement, and citizen science.

  7. Moisture related test protocols for HVS testing

    CSIR Research Space (South Africa)

    Denneman, E

    2008-10-01

    Full Text Available outcomes of HVS tests where the moisture condition of the pavement or specific layers in the pavement is under investigation for a specific test. Practical guidance is then provided on the potential systems (how to manage the moisture – hardware) as well...

  8. The Caledonian face test: A new test of face discrimination.

    Science.gov (United States)

    Logan, Andrew J; Wilkinson, Frances; Wilson, Hugh R; Gordon, Gael E; Loffler, Gunter

    2016-02-01

    This study aimed to develop a clinical test of face perception which is applicable to a wide range of patients and can capture normal variability. The Caledonian face test utilises synthetic faces which combine simplicity with sufficient realism to permit individual identification. Face discrimination thresholds (i.e. minimum difference between faces required for accurate discrimination) were determined in an "odd-one-out" task. The difference between faces was controlled by an adaptive QUEST procedure. A broad range of face discrimination sensitivity was determined from a group (N=52) of young adults (mean 5.75%; SD 1.18; range 3.33-8.84%). The test is fast (3-4 min), repeatable (test-re-test r(2)=0.795) and demonstrates a significant inversion effect. The potential to identify impairments of face discrimination was evaluated by testing LM who reported a lifelong difficulty with face perception. While LM's impairment for two established face tests was close to the criterion for significance (Z-scores of -2.20 and -2.27) for the Caledonian face test, her Z-score was -7.26, implying a more than threefold higher sensitivity. The new face test provides a quantifiable and repeatable assessment of face discrimination ability. The enhanced sensitivity suggests that the Caledonian face test may be capable of detecting more subtle impairments of face perception than available tests. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Materials testing 1985

    International Nuclear Information System (INIS)

    1985-01-01

    The following subjects were dealt with at the meeting: Testing with vibration loads; Hardness testing; Calibration of test devices and equipment; Test technique for compound materials; Vibration strength testing and expense of experiments; Solving problems in introducing forces into samples and components and process of ambulant materials testing. There are 17 separate abstracts from among 43 lectures. (orig./PW) [de

  10. Pragmatics of Testing

    Directory of Open Access Journals (Sweden)

    İsmail Fırat ALTAY

    2007-10-01

    Full Text Available Teaching of a language is a very complicated issue and testing is anindispensable part of this matter. Thanks to testing teachers can assess efficiency ofteaching and learning atmosphere, and can get feedback about their learners. In order torealize this, a test should have some qualifications. One of these qualifications is aboutpragmatics. This paper aims at explaining what makes a test pragmatic and howpragmatic tests can be formed. So, examples of pragmatic tests of different types arepresented with explanations. Their pragmatic components and nature are focused on bygiving example test items on the problematic area of test questions prepared. Finally,the writer states his last words by making further comments and explanations onpragmatics of testing in the conclusion part.

  11. Numerical simulations of rubber bearing tests and shaking table tests

    International Nuclear Information System (INIS)

    Hirata, K.; Matsuda, A.; Yabana, S.

    2002-01-01

    Test data concerning rubber bearing tests and shaking table tests of base-isolated model conducted by CRIEPI are provided to the participants of Coordinated Research Program (CRP) on 'Intercomparison of Analysis Methods for predicting the behaviour of Seismically Isolated Nuclear Structure', which is organized by International Atomic Energy Agency (IAEA), for the comparison study of numerical simulation of base-isolated structure. In this paper outlines of the test data provided and the numerical simulations of bearing tests and shaking table tests are described. Using computer code ABAQUS, numerical simulations of rubber bearing tests are conducted for NRBs, LRBs (data provided by CRIEPI) and for HDRs (data provided by ENEA/ENEL and KAERI). Several strain energy functions are specified according to the rubber material test corresponding to each rubber bearing. As for lead plug material in LRB, mechanical characteristics are reevaluated and are made use of. Simulation results for these rubber bearings show satisfactory agreement with the test results. Shaking table test conducted by CRIEPI is of a base isolated rigid mass supported by LRB. Acceleration time histories, displacement time histories of the isolators as well as cyclic loading test data of the LRB used for the shaking table test are provided to the participants of the CRP. Simulations of shaking table tests are conducted for this rigid mass, and also for the steel frame model which is conducted by ENEL/ENEA. In the simulation of the rigid mass model test, where LRBs are used, isolators are modeled either by bilinear model or polylinear model. In both cases of modeling of isolators, simulation results show good agreement with the test results. In the case of the steel frame model, where HDRs are used as isolators, bilinear model and polylinear model are also used for modeling isolators. The response of the model is simulated comparatively well in the low frequency range of the floor response, however, in

  12. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1999

    Energy Technology Data Exchange (ETDEWEB)

    Kawasaki, Nobuo; Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru [Fujitsu Ltd., Tokyo (Japan); Ogasawara, Shinobu; Kume, Etsuo; Adachi, Masaaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Yatake, Yo-ichi [Hitachi Ltd., Tokyo (Japan)

    2001-01-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system, the SX-4 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 18 codes in fiscal 1999. These results are reported in 3 parts, i.e., the vectorization and the parallelization part on vector processors, the parallelization port on scalar processors and the porting part. In this report, we describe the porting. In this porting part, the porting of Assisted Model Building with Energy Refinement code version 5 (AMBER5), general purpose Monte Carlo codes far neutron and photon transport calculations based on continuous energy and multigroup methods (MVP/GMVP), automatic editing system for MCNP library code (autonj), neutron damage calculations for materials irradiations and neutron damage calculations for compounds code (SPECTER/SPECOMP), severe accident analysis code (MELCOR) and COolant Boiling in Rod Arrays, Two-Fluid code (COBRA-TF) on the VPP500 system and/or the AP3000 system are described. (author)

  13. Crippling load test of Budd Pioneer Car 244, test 3.

    Science.gov (United States)

    2013-04-01

    This report summarizes Test 3, a crippling load test on Budd Pioneer Car 244, conducted on June 28, 2011. Before the crippling load test, Transportation Technology Center, Inc., conducted two 800,000-pound (lb) quasi-static tests on Car 244 in accord...

  14. Test-Taking Strategies in L2 Assessment: The Test of English for International Communication Speaking Test.

    Science.gov (United States)

    Huang, Heng-Tsung Danny

    2016-08-01

    This research explored the test-taking strategies associated with the Test of English for International Communication Speaking Test (TOEIC-S) and their relationship with test performance. Capitalizing on two sets of TOEIC-S and a custom-made strategy inventory, the researcher collected data from a total of 215 Taiwanese English learners consisting of 84 males and 131 females with an average age of 20.1 years (SD = 2.6). Quantitative data analysis gave rise to three major findings. First, TOEIC-S test-taking strategy use constituted a multi-faceted construct that involved multiple types of strategic behaviors. Second, these strategic behaviors matched those allowing test-takers to communicate both in real life and in the workplace. Third, communication strategy use and cognitive strategy use both contributed significantly to TOEIC-S performance. © The Author(s) 2016.

  15. Aerospace Structures Test Facility Environmental Test Chambers (ETC)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The ETCs test the structural integrity of aerospace structures in representative operating temperatures and aerodynamic load distributions. The test article...

  16. Goodness of Fit Test and Test of Independence by Entropy

    Directory of Open Access Journals (Sweden)

    M. Sharifdoost

    2009-06-01

    Full Text Available To test whether a set of data has a specific distribution or not, we can use the goodness of fit test. This test can be done by one of Pearson X 2 -statistic or the likelihood ratio statistic G 2 , which are asymptotically equal, and also by using the Kolmogorov-Smirnov statistic in continuous distributions. In this paper, we introduce a new test statistic for goodness of fit test which is based on entropy distance, and which can be applied for large sample sizes. We compare this new statistic with the classical test statistics X 2 , G 2 , and Tn by some simulation studies. We conclude that the new statistic is more sensitive than the usual statistics to the rejection of distributions which are almost closed to the desired distribution. Also for testing independence, a new test statistic based on mutual information is introduced

  17. Endurance test for IR rig for RI production assembly (test procedure)

    International Nuclear Information System (INIS)

    Chung, Heung June; Ryu, Jeong Soo

    2000-08-01

    This test procedure details the test loop, test method, and test procedure for pressure drop, vibration and endurance test of IR Rig for RI production. From the pressure drop test, the hydraulic design requirements of the capsule are verified. HANARO limit condition is checked and the compatibility with HANARO core is verified. From flow induced vibration test vibration frequency and displacement are investigated. The wear of IR Rig is investigated through endurance test, and these data are used to evaluate the expected wear at maximum resident time of the IR Rig for RI production

  18. Summary of ALSEP Test Loop Solvent Irradiation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Peterman, Dean Richard [Idaho National Lab. (INL), Idaho Falls, ID (United States); Olson, Lonnie Gene [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Separating the minor actinide elements (americium and curium) from the fission product lanthanides is an important step in closing the nuclear fuel cycle. Isolating the minor actinides will allow transmuting them to short lived or stable isotopes in fast reactors, thereby reducing the long-term hazard associated with these elements. The Actinide Lanthanide Separation Process (ALSEP) is being developed by the DOE-NE Material Recovery and Waste Form Development Campaign to accomplish this separation with a single process. To develop a fundamental understanding of the solvent degradation mechanisms for the ALSEP Process, testing was performed in the INL Radiolysis/Hydrolysis Test Loop for the extraction section of the ALSEP flowsheet. This work culminated in the completion of the level two milestone (M2FT-16IN030102021) "Complete ALSEP test loop solvent irradiation test.” This report summarizes the testing performed and the impact of radiation on the ALSEP Process performance as a function of dose.

  19. A Real Time Electronics Emulator with Realistic Data Generation for Reception Tests of the CMS ECAL Front-End Boards

    CERN Document Server

    Romanteau, T; Collard, Caroline; Debraine, A; Decotigny, D; Dobrzynski, L; Karar, A; Regnault, N

    2005-01-01

    The CMS [1] electromagnetic calorimeter (ECAL) [2] uses 3 132 Front-End boards (FE) performing both trigger and data readout functions. Prior to their integration at CERN, the FE boards have to be validated by dedicated test bench systems. The final one, called "XFEST" (eXtended Front-End System Test) and for which the present developments have been performed, is located at Laboratoire Leprince-Ringuet. In this contribution, a solution is described to efficiently test a large set of complex electronics boards characterized by a large number of input ports and a high throughput data rate. To perform it, an algorithm to simulate the Very Front End signals has been emulated. The project firmwares use VHDL embedded into XILINX Field Programmable Gate Array circuits (FPGA). This contribution describes the solutions developed in order to create a realistic digital input patterns real-time emul ator working at 40 MHz. The implementation of a real time comparison of the FE output streams as well as the test bench wil...

  20. FENIX [Fusion ENgineering International eXperimental]: A test facility for ITER [International Thermonuclear Experimental Reactor] and other new superconducting magnets

    International Nuclear Information System (INIS)

    Slack, D.S.; Patrick, R.E.; Miller, J.R.

    1990-01-01

    The Fusion ENgineering International eXperimental (FENIX) Test Facility which is nearing completion at Lawrence Livermore National Laboratory, is a 76-t set of superconducting magnets housed in a 4-m-diameter cryostat. It represents a significant step toward meeting the testing needs for the development of superconductors appropriate for large-scale magnet applications such as the International Thermonuclear Experimental Reactor (ITER). The magnet set is configured to allow radial access to the 0.4-m-diameter high-field region where maximum fields up to 14 T will be provided. The facility is fitted with a thermally isolated test well with a port to the high-field region that allows insertion and removal of test conductors without disturbing the cryogenic environment of the magnets. It is expected that the facility will be made available to magnet developers internationally, and this paper discusses its general design features, its construction, and its capabilities

  1. Mollusc reproductive toxicity tests - Development and validation of test guidelines

    DEFF Research Database (Denmark)

    Ducrot, Virginie; Holbech, Henrik; Kinnberg, Karin Lund

    . Draft standard operating procedures (SOPs) have been designed based upon literature and expert knowledge from project partners. Pre-validation studies have been implemented to validate the proposed test conditions and identify issues in performing the SOPs and analyzing test results. Pre-validation work......The Organisation for Economic Cooperation and Development is promoting the development and validation of mollusc toxicity tests within its test guidelines programme, eventually aiming for the standardization of mollusc apical toxicity tests. Through collaborative work between academia, industry...... and stakeholders, this study aims to develop innovative partial life-cycle tests on the reproduction of the freshwater gastropods Potamopyrgus antipodarum and Lymnaea stagnalis, which are relevant candidate species for the standardization of mollusc apical toxicity tests assessing reprotoxic effects of chemicals...

  2. The Flexible Port

    NARCIS (Netherlands)

    Taneja, P.

    2013-01-01

    Ports are beset with many uncertainties about their futures. They are confronted with new demands in terms of functions and scales, new external constraints, and changed expectations. The inability to adequately meet these demands can mean costly adaptations for a port, or loss of cargo and

  3. [Using projective tests in forensic psychiatry may lead to wrong conclusions. Only empirically tested tests should be used].

    Science.gov (United States)

    Trygg, L; Dåderman, A M; Wiklund, N; Meurling, A W; Lindgren, M; Lidberg, L; Levander, S

    2001-06-27

    The use of projective and psychometric psychological tests at the Department of Forensic Psychiatry in Stockholm (Huddinge), Sweden, was studied for a population of 60 men, including many patients with neuropsychological disabilities and multiple psychiatric disorders. The results showed that the use of projective tests like Rorschach, Object Relations Test, and House-Tree-Person was more frequent than the use of objective psychometric tests. Neuropsychological test batteries like the Halstead-Reitan Neuropsychological Test Battery or Luria-Nebraska Neuropsychological Battery were not used. The majority of patients were, however, assessed by intelligence scales like the WAIS-R. The questionable reliability and validity of the projective tests, and the risk of subjective interpretations, raise a problem when used in a forensic setting, since the courts' decisions about a sentence to prison or psychiatric care is based on the forensic psychiatric assessment. The use of objective psychometric neuropsychological tests and personality tests is recommended.

  4. VDRL test

    Science.gov (United States)

    ... confirmed with another blood test to make the diagnosis of syphilis. Normal value ranges may vary slightly among different ... broken) Alternative Names Venereal disease research ... laboratory test (VDRL) – serum. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; ...

  5. Analog automatic test pattern generation for quasi-static structural test.

    NARCIS (Netherlands)

    Zjajo, A.; Pineda de Gyvez, J.

    2009-01-01

    A new approach for structural, fault-oriented analog test generation methodology to test for the presence of manufacturing-related defects is proposed. The output of the test generator consists of optimized test stimuli, fault coverage and sampling instants that are sufficient to detect the failure

  6. Multiple Choice Testing and the Retrieval Hypothesis of the Testing Effect

    Science.gov (United States)

    Sensenig, Amanda E.

    2010-01-01

    Taking a test often leads to enhanced later memory for the tested information, a phenomenon known as the "testing effect". This memory advantage has been reliably demonstrated with recall tests but not multiple choice tests. One potential explanation for this finding is that multiple choice tests do not rely on retrieval processes to the same…

  7. CSF-VDRL test

    Science.gov (United States)

    ... test - CSF; Neurosyphilis - VDRL Images CSF test for syphilis References Chernecky CC, Berger BJ. Venereal disease research laboratory test (VDRL), test, cerebrospinal fluid – specimen. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; ...

  8. Relay test program

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.K.; Kunkel, C.; Shteyngart, S.

    1994-02-01

    This report presents the results of a relay test program conducted by Brookhaven National Laboratory (BNL) under the sponsorship of the US Nuclear Regulatory Commission (NRC). The program is a continuation of an earlier test program the results of which were published in NUREG/CR-4867. The current program was carried out in two phases: electrical testing and vibration testing. The objective was primarily to focus on the electrical discontinuity or continuity of relays and circuit breaker tripping mechanisms subjected to electrical pulses and vibration loads. The electrical testing was conducted by KEMA-Powertest Company and the vibration testing was performed at Wyle Laboratories, Huntsville, Alabama. This report discusses the test procedures, presents the test data, includes an analysis of the data and provides recommendations regarding reliable relay testing

  9. Gas Test Loop Booster Fuel Hydraulic Testing

    International Nuclear Information System (INIS)

    Gas Test Loop Hydraulic Testing Staff

    2006-01-01

    The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3

  10. Gas Test Loop Booster Fuel Hydraulic Testing

    Energy Technology Data Exchange (ETDEWEB)

    Gas Test Loop Hydraulic Testing Staff

    2006-09-01

    The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3.

  11. Rise-to-power test in High Temperature Engineering Test Reactor. Test progress and summary of test results up to 30 MW of reactor thermal power

    International Nuclear Information System (INIS)

    Nakagawa, Shigeaki; Fujimoto, Nozomu; Shimakawa, Satoshi

    2002-08-01

    The High Temperature Engineering Test Reactor (HTTR) is a graphite moderated and gas cooled reactor with the thermal power of 30 MW and the reactor outlet coolant temperature of 850degC/950degC. Rise-to-power test in the HTTR was performed from April 23rd to June 6th in 2000 as phase 1 test up to 10 MW in the rated operation mode, from January 29th to March 1st in 2001 as phase 2 test up to 20 MW in the rated operation mode and from April 14th to June 8th in 2001 as phase 3 test up to 20 MW in the high temperature test the mechanism of the reactor outlet coolant temperature becomes 850degC at 30 MW in the rated operation mode and 950degC in the high temperature test operation mode. Phase 4 rise-to-power test to achieve the thermal reactor power of 30 MW started on October 23rd in 2001. On December 7th in 2001 it was confirmed that the thermal reactor power and the reactor outlet coolant temperature reached to 30 MW and 850degC respectively in the single loaded operation mode in which only the primary pressurized water cooler is operating. Phase 4 test was performed until March 6th in 2002. JAERI (Japan Atomic Energy Research Institute) obtained the certificate of the pre-operation test from MEXT (Ministry of Education Culture Sports Science and Technology) after all the pre-operation tests by MEXT were passed successfully with the reactor transient test at an abnormal event as a final pre-operation test. From the test results of the rise-up-power test up to 30 MW in the rated operation mode, performance of the reactor and cooling system were confirmed, and it was also confirmed that an operation of reactor facility can be performed safely. Some problems to be solved were found through the tests. By solving them, the reactor operation with the reactor outlet coolant temperature of 950degC will be achievable. (author)

  12. Principal Ports and Facilities

    Data.gov (United States)

    California Natural Resource Agency — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  13. Principal Ports and Facilities

    Data.gov (United States)

    California Department of Resources — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  14. Experimental test results of multi-channel test rig of T1 test section, 5

    International Nuclear Information System (INIS)

    Hino, Ryutaro; Takase, Kazuyuki; Miyamoto, Yoshiaki

    1990-09-01

    Channel blockage test on a fuel column of the high temperature engineering test reactor (HTTR) has been performed under the helium gas atmosphere at a high temperature and a high pressure in order to obtain safety data on flow rate and temperature distributions in the fuel column with the multi-channel test rig of the fuel stack test section (T 1 ) in HENDEL. In the test, one of 12 fuel channels was blockaded to 90% of flow area at the channel inlet. Experimental results showed that the helium gas flow rate in the blockaded channel was 28%∼33% lower than the average flow rate for Reynolds number from 2300 to 14000 in isothermal flow. When simulated fuel rods were heated, the flow rate in the blockaded channel did not decrease down in comparison with the isothermal flow. This is due to that the heat generated in the fuel rods conducts to the other fuel channels in graphite fuel blocks, so that accelerated pressure losses in the fuel channels change with helium gas temperatures. (author)

  15. CANFLEX fuel bundle cross-flow endurance test (test report)

    International Nuclear Information System (INIS)

    Hong, Sung Deok; Chung, C. H.; Chang, S. K.; Kim, B. D.

    1997-04-01

    As part of the normal refuelling sequence of CANDU nuclear reactor, both new and irradiated bundles can be parked in the cross-flow region of the liner tubes. This situation occurs normally for a few minutes. The fuel bundle which is subjected to the cross-flow should be capable of withstanding the consequences of cross flow for normal periods, and maintain its mechanical integrity. The cross-flow endurance test was conducted for CANFLEX bundle, latest developed nuclear fuel, at CANDU-Hot Test Loop. The test was carried out during 4 hours at the inlet cross-flow region. After the test, the bundle successfully met all acceptance criteria after the 4 hours cross-flow test. (author). 2 refs., 3 tabs

  16. CANFLEX fuel bundle cross-flow endurance test (test report)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Deok; Chung, C. H.; Chang, S. K.; Kim, B. D.

    1997-04-01

    As part of the normal refuelling sequence of CANDU nuclear reactor, both new and irradiated bundles can be parked in the cross-flow region of the liner tubes. This situation occurs normally for a few minutes. The fuel bundle which is subjected to the cross-flow should be capable of withstanding the consequences of cross flow for normal periods, and maintain its mechanical integrity. The cross-flow endurance test was conducted for CANFLEX bundle, latest developed nuclear fuel, at CANDU-Hot Test Loop. The test was carried out during 4 hours at the inlet cross-flow region. After the test, the bundle successfully met all acceptance criteria after the 4 hours cross-flow test. (author). 2 refs., 3 tabs.

  17. Do Test Design and Uses Influence Test Preparation? Testing a Model of Washback with Structural Equation Modeling

    Science.gov (United States)

    Xie, Qin; Andrews, Stephen

    2013-01-01

    This study introduces Expectancy-value motivation theory to explain the paths of influences from perceptions of test design and uses to test preparation as a special case of washback on learning. Based on this theory, two conceptual models were proposed and tested via Structural Equation Modeling. Data collection involved over 870 test takers of…

  18. Handling of waste in ports

    International Nuclear Information System (INIS)

    Olson, P.H.

    1994-01-01

    The regulations governing the handling of port-generated waste are often national and/or local legislation, whereas the handling of ship-generated waste is governed by the MARPOL Convention in most parts of the world. The handling of waste consists of two main phases -collection and treatment. Waste has to be collected in every port and on board every ship, whereas generally only some wastes are treated and to a certain degree in ports and on board ships. This paper considers the different kinds of waste generated in both ports and on board ships, where and how it is generated, how it could be collected and treated. The two sources are treated together to show how some ship-generated waste may be treated in port installations primarily constructed for the treatment of the port-generated waste, making integrated use of the available treatment facilities. (author)

  19. Ultrasonic testing

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Jin [Sungkwunkwan Univ., Seoul (Korea, Republic of); Jeong, Hyun Jo [Wonkwang Univ., Iksan (Korea, Republic of)

    2004-02-15

    For the proper performance of ultrasonic testing of steel welded joints, and anisotropic material it is necessary to have sound understanding on the underlying physics. To provide such an understanding, it is beneficial to have simulation tools for ultrasonic testing. In order to address such a need, we develop effective approaches to simulate angle beam ultrasonic testing with a personal computer. The simulation is performed using ultrasonic measurement models based on the computationally efficient multi-Gaussian beams. This reach will describe the developed ultrasonic testing models together with the experimental verification of their accuracy.

  20. Myoglobin urine test

    Science.gov (United States)

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  1. Ferritin Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Ferritin, Serum; 296 p. Lab Tests ...

  2. Porting the 3D Gyrokinetic Particle-in-cell Code GTC to the CRAY/NEC SX-6 Vector Architecture: Perspectives and Challenges

    International Nuclear Information System (INIS)

    Ethier, S.; Lin, Z.

    2003-01-01

    Several years of optimization on the super-scalar architecture has made it more difficult to port the current version of the 3D particle-in-cell code GTC to the CRAY/NEC SX-6 vector architecture. This paper explains the initial work that has been done to port this code to the SX-6 computer and to optimize the most time consuming parts. Early performance results are shown and compared to the same test done on the IBM SP Power 3 and Power 4 machines

  3. CANFLEX fuel bundle cross-flow endurance test 2 (test procedure)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Deok; Chung, C. H.; Chang, S. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-04-01

    This report describes test procedure of cross-flow 2 test for CANFLEX fuel. In October 1996. a cross-flow test was successfully performed in the KAERI Hot Test Loop for four hours at a water flow rate of 31kg/s, temperature of 266 deg C and inlet pressure of 11MPa, but it is requested more extended time periods to determine a realistic operational margin for the CANFLEX bundle during abnormal refuelling operations. The test shall be conducted for twenty two hours under the reactor conditions. After an initial period of ten hours, the test shall be stopped at the intervals of four hours for bundle inspection and inspect the test bundle end-plate to end-cap welds for failure or crack propagation using liquid penetrant examination. 2 refs., 1 fig. (Author)

  4. Dynamic testing of adhesive joints using a shock testing machine

    NARCIS (Netherlands)

    Aanhold, J.E. van; Weersink, A.F.J.; Ludolphy, J.W.L.

    1998-01-01

    A light-weight shock testing machine, designed for type approval testing of naval equipment up to 300 kg mass, has been modified into a dynamic tensile test rig. This enables to test structural details for high rate dynamic tensile loadings such as occur during underwater shock. The maximum capacity

  5. ILAW Glass Testing for Disposal at IDF: Phase 1 Testing

    Energy Technology Data Exchange (ETDEWEB)

    Papathanassiu, Adonia [The Catholic Univ. of America, Washington, DC (United States). Virteous State Lab.; Muller, Isabelle S. [The Catholic Univ. of America, Washington, DC (United States). Virteous State Lab.; Brandys, Marek [The Catholic Univ. of America, Washington, DC (United States). Virteous State Lab.; Gilbo, Konstantin [The Catholic Univ. of America, Washington, DC (United States). Virteous State Lab.; Barkatt, Aaron [The Catholic Univ. of America, Washington, DC (United States). Virteous State Lab.; Joseph, Innocent [EnergySolutions Federal EPC, Inc., Columbia, MD (United States); The Catholic Univ. of America, Washington, DC (United States). Virteous State Lab.; Pegg, Ian L. [The Catholic Univ. of America, Washington, DC (United States). Virteous State Lab.; Brown, Elvie E. [Washington River Protection Solutions, LLC, Richland, WA (United States); Swanberg, David J. [Washington River Protection Solutions, LLC, Richland, WA (United States)

    2011-04-11

    This document reports the results of the testing of phase 1 ORP LAW (low activity waste) glasses, also identified as enhanced LAW glasses. Testing involved are SPFT (Single Pass Flow Through), VHT (Vapor Hydration Test), and PCT (Product Consistency Test), along with the analytical tests (XRD and SEM-EDS). This report contains the data of the high waste loading ORP LAW glasses that will be used for the performance assessment of the IDF (Integrated Disposal Facility).

  6. ILAW Glass Testing for Disposal at IDF: Phase 1 Testing

    International Nuclear Information System (INIS)

    Papathanassiu, Adonia; Swanberg, David J.

    2011-01-01

    This document reports the results of the testing of phase 1 ORP LAW (low activity waste) glasses, also identified as enhanced LAW glasses. Testing involved are SPFT (Single Pass Flow Through), VHT (Vapor Hydration Test), and PCT (Product Consistency Test), along with the analytical tests (XRD and SEM-EDS). This report contains the data of the high waste loading ORP LAW glasses that will be used for the performance assessment of the IDF (Integrated Disposal Facility).

  7. Simplified Freeman-Tukey test statistics for testing probabilities in ...

    African Journals Online (AJOL)

    This paper presents the simplified version of the Freeman-Tukey test statistic for testing hypothesis about multinomial probabilities in one, two and multidimensional contingency tables that does not require calculating the expected cell frequencies before test of significance. The simplified method established new criteria of ...

  8. 40 CFR 53.64 - Test procedure: Static fractionator test.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedure: Static fractionator test. 53.64 Section 53.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Performance Characteristics of Class II Equivalent Methods for PM2.5 § 53.64 Test procedure: Static...

  9. TOP 01-1-011B Vehicle Test Facilities at Aberdeen Test Center and Yuma Test Center

    Science.gov (United States)

    2017-12-12

    Test Center 400 Colleran Road Aberdeen Proving Ground, MD 21005-5059 U.S. Army Yuma Proving Ground Yuma Test Center 301 C. Street Yuma, AZ...22 2.6 Munson Test Area (MTA) ..................................................... 24 2.7 Land Vehicle Maintenance Facility...127 3.6 Maintenance Facilities ........................................................... 143

  10. Test plan for ISV laboratory-pyrolysis testing

    Energy Technology Data Exchange (ETDEWEB)

    McAtee, R.E.

    1991-09-01

    The objective of the laboratory-pyrolysis studies is to obtain information on the high temperature (< 1200{degree}C) degradation and alteration of organic chemicals and materials similar to those found in the Radioactive Waste Management Complex, Pit 9. This test plan describes experimental procedures, sampling and analysis strategy, sampling procedures, sample control, and document management. It addresses safety issues in the experimental apparatus and procedures, personal training, and hazardous waste disposal. Finally, it describes the data quality objectives using the EPA tiered approach to treatability studies to define where research/scoping tests fit into these studies and the EPA analytical levels required for the tests.

  11. Vacuum vessel port structures for ITER-FEAT

    International Nuclear Information System (INIS)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th.

    2001-01-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed

  12. Vacuum vessel port structures for ITER-FEAT

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th

    2001-11-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed.

  13. Test report for run-in acceptance testing of hydrogen mitigation test pump-2

    International Nuclear Information System (INIS)

    Brewer, A.K.; Kolowith, R.

    1995-01-01

    This document provides the results of the run-in test of the replacement mixer pump for the Tank 241-SY-101. The test was conducted at the 400 Area MASF facility between August 12 and September 29, 1994. The report includes findings, analysis, recommendations, and corrective actions taken

  14. The testing effect for mediator final test cues and related final test cues in online and laboratory experiments.

    Science.gov (United States)

    Coppens, Leonora C; Verkoeijen, Peter P J L; Bouwmeester, Samantha; Rikers, Remy M J P

    2016-05-31

    The testing effect is the finding that information that is retrieved during learning is more often correctly retrieved on a final test than information that is restudied. According to the semantic mediator hypothesis the testing effect arises because retrieval practice of cue-target pairs (mother-child) activates semantically related mediators (father) more than restudying. Hence, the mediator-target (father-child) association should be stronger for retrieved than restudied pairs. Indeed, Carpenter (2011) found a larger testing effect when participants received mediators (father) than when they received target-related words (birth) as final test cues. The present study started as an attempt to test an alternative account of Carpenter's results. However, it turned into a series of conceptual (Experiment 1) and direct (Experiment 2 and 3) replications conducted with online samples. The results of these online replications were compared with those of similar existing laboratory experiments through small-scale meta-analyses. The results showed that (1) the magnitude of the raw mediator testing effect advantage is comparable for online and laboratory experiments, (2) in both online and laboratory experiments the magnitude of the raw mediator testing effect advantage is smaller than in Carpenter's original experiment, and (3) the testing effect for related cues varies considerably between online experiments. The variability in the testing effect for related cues in online experiments could point toward moderators of the related cue short-term testing effect. The raw mediator testing effect advantage is smaller than in Carpenter's original experiment.

  15. Dtest Testing Software

    Science.gov (United States)

    Jain, Abhinandan; Cameron, Jonathan M.; Myint, Steven

    2013-01-01

    This software runs a suite of arbitrary software tests spanning various software languages and types of tests (unit level, system level, or file comparison tests). The dtest utility can be set to automate periodic testing of large suites of software, as well as running individual tests. It supports distributing multiple tests over multiple CPU cores, if available. The dtest tool is a utility program (written in Python) that scans through a directory (and its subdirectories) and finds all directories that match a certain pattern and then executes any tests in that directory as described in simple configuration files.

  16. ITER test programme

    International Nuclear Information System (INIS)

    Abdou, M.; Baker, C.; Casini, G.

    1991-01-01

    ITER has been designed to operate in two phases. The first phase which lasts for 6 years, is devoted to machine checkout and physics testing. The second phase lasts for 8 years and is devoted primarily to technology testing. This report describes the technology test program development for ITER, the ancillary equipment outside the torus necessary to support the test modules, the international collaboration aspects of conducting the test program on ITER, the requirements on the machine major parameters and the R and D program required to develop the test modules for testing in ITER. 15 refs, figs and tabs

  17. COSIMA-ES-PORT

    DEFF Research Database (Denmark)

    Barfod, Michael Bruhn; Leleur, Steen

    2007-01-01

    This article describes the results of the research project – WP3 East-west, Interreg IIIB – concerning the de¬velop¬ment of a new composite decision model, COSIMA-ES-PORT, for the assessment of three pre-feasibility studies situated at the Port of Esbjerg: a road project, a railway project...... and a multimodal terminal. The three studies indicates that a new road connection to the Port of Esbjerg is a very profitable project due to large travel time savings, whereas a new railway connection is not economically viable. However, a new multimodal terminal is also a very profitable project. The COSIMA...

  18. UAS-NAS Flight Test Series 3: Test Environment Report

    Science.gov (United States)

    Hoang, Ty; Murphy, Jim; Otto, Neil

    2016-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration in the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability (SSI), Human Systems Integration (HSI), and Communications (Comm), and Certification to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Detect and Avoid (DAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project is conducting a series of human-in-the-loop (HITL) and flight test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity, and

  19. Retention of Prose Following Testing with Different Types of Tests.

    Science.gov (United States)

    Duchastel, Philippe C.

    1981-01-01

    Taking a test on a passage one has just studied is known to enhance later retention. This effect was influenced by the type of initial test used. It was evident in the case of the initial short-answer test, but not in the case of multiple choice and free recall tests. (Author/RD)

  20. Project W-320, operational test procedure OTP-320-003 test report

    International Nuclear Information System (INIS)

    Bevins, R.R.

    1998-01-01

    This report documents and summarizes the results of OTP-320-003 Project W-320 Operational Testing of the WRSS Supernate Transfer System. Project W-320 Operational Test OTP-320-003 was performed to verify components of the Waste Retrieval Sluicing System (WRSS) supernate transfer system functioned as designed following construction completion and turnover to operations. All equipment operation was performed by Tank Farms Operations personnel following the operational test procedure and referenced operating procedures. Supernate Transfer line Flushing System Testing was completed over the course of approximately 4 weeks as tank farm conditions and configuration, equipment availability, and operations resources allowed. All testing was performed with the 702-AZ ventilation system and the 296-P-16 ventilation systems in operation. Test procedure OTP-320-003 required two revisions during testing to incorporate Procedure Changes Authorizations (PCAs) necessary to facilitate testing. Various sections of testing are documented on each procedure revision. The completed test procedure is included as Attachment A. Exception Reports generated during the course of testing are included as Attachment B

  1. Test plan for Tank 241-AW-101 solubility screening tests

    International Nuclear Information System (INIS)

    Person, J.C.

    1998-01-01

    Tank 241-AW-101 (101-AW) has been identified as one of the early tanks to be for retrieved for low level waste pretreatment and immobilization and retrieval of the tank waste may require dilution. This test is to determine the effects of dilution on the mass of solids and their composition. This test plan gives test instructions, example data sheets, a waste compatibility review, and a waste stream fact sheet. This test Plan is similar to tests on tanks 241-AN-102 (Person 1998a) and 241-AN-107 (Person 1998 b). The 101-AW tests will be done with composites of liquid and solids from grab samples that were taken in 1998 (Benar 1998). Future revisions of the Tank Sampling and Analysis Plan (Benar 1998) may change the details of the work performed under this test plan

  2. Lactose tolerance tests

    Science.gov (United States)

    Hydrogen breath test for lactose tolerance ... Two common methods include: Lactose tolerance blood test Hydrogen breath test The hydrogen breath test is the preferred method. It measures the amount of hydrogen ...

  3. Anthrax blood test

    Science.gov (United States)

    Anthrax serology test; Antibody test for anthrax; Serologic test for B. anthracis ... This test may be performed when the health care provider suspects you have anthrax infection. The bacteria that cause ...

  4. Ketones urine test

    Science.gov (United States)

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  5. Management of Artisanal Fishing Port: a Case Study on Labuhanhaji Fishing Port, South Aceh Regency, Aceh Province

    OpenAIRE

    NurJannah, Betri; ', Syaifuddin; Zain, Jonny

    2014-01-01

    A series survey activity was carried out for evaluating management function atlabuanhaji fishing port, South Aceh regency. This research was emphasis on planning, organizing, action and controlling at management pattern of labuhanhaji fishing port. The facilities of fishing port data and daily activities description of staff at labuhanhaji fishing port was used as additional information and consideration in management of labuhanhaji fishing port. Lack of good management was impact on staff an...

  6. Myoglobin blood test

    Science.gov (United States)

    Serum myoglobin; Heart attack - myoglobin blood test; Myositis - myoglobin blood test; Rhabdomyolysis - myoglobin blood test ... too high, it can damage the kidneys. This test is ordered when your health care provider suspects ...

  7. ICH antenna development on the ORNL RF Test Facility

    International Nuclear Information System (INIS)

    Gardner, W.L.; Bigelow, T.S.; Haste, G.R.; Hoffman, D.J.; Livesey, R.L.

    1987-01-01

    A compact resonant loop antenna is installed on the ORNL Radio Frequency Test Facility (RFTF). Facility characteristics include a steady-state magnetic field of ∼ 0.5 T at the antenna, microwave-generated plasmas with n e ∼ 10 12 cm -3 and T e ∼ 8 eV, and 100 kW of 25-MHz rf power. The antenna is tunable from ∼22--75 MHz, is designed to handle ≥1 MW of rf power, and can be moved 5 cm with respect to the port flange. Antenna characteristics reported and discussed include the effect of magnetic field on rf voltage breakdown at the capacitor, the effects of magnetic field and plasma on rf voltage breakdown between the radiating element and the Faraday shield, the effects of graphite on Faraday shield losses, and the efficiency of coupling to the plasma. 2 refs., 4 figs

  8. Development of an Integrated Leachate Treatment Solution for the Port Granby Waste Management Facility - 12429

    Energy Technology Data Exchange (ETDEWEB)

    Conroy, Kevin W. [Golder Associates Inc., Lakewood, Colorado (United States); Vandergaast, Gerald [Atomic Energy of Canada Limited, Port Hope, Ontario (Canada)

    2012-07-01

    The Port Granby Project (the Project) is located near the north shore of Lake Ontario in the Municipality of Clarington, Ontario, Canada. The Project consists of relocating approximately 450,000 m{sup 3} of historic Low-Level Radioactive Waste (LLRW) and contaminated soil from the existing Port Granby Waste Management Facility (WMF) to a proposed Long-Term Waste Management Facility (LTWMF) located adjacent to the WMF. The LTWMF will include an engineered waste containment facility, a Wastewater Treatment Plant (WTP), and other ancillary facilities. A series of bench- and pilot-scale test programs have been conducted to identify preferred treatment processes to be incorporated into the WTP to treat wastewater generated during the construction, closure and post-closure periods at the WMF/LTWMF. (authors)

  9. A power recirculating test rig for ball screw endurance tests

    Directory of Open Access Journals (Sweden)

    Giberti Hermes

    2016-01-01

    Full Text Available A conceptual design of an innovative test rig for endurance tests of ball screws is presented in this paper. The test rig layout is based on the power recirculating principle and it also allows to overtake the main critical issues of the ball screw endurance tests. Among these there are the high power required to make the test, the lengthy duration of the same and the high loads between the screw and the frame that holds it. The article describes the test rig designed scheme, the kinematic expedients to be adopted in order to obtain the required performance and functionality and the sizing procedure to choose the actuation system.

  10. Goodness of Fit Test and Test of Independence by Entropy

    OpenAIRE

    M. Sharifdoost; N. Nematollahi; E. Pasha

    2009-01-01

    To test whether a set of data has a specific distribution or not, we can use the goodness of fit test. This test can be done by one of Pearson X 2 -statistic or the likelihood ratio statistic G 2 , which are asymptotically equal, and also by using the Kolmogorov-Smirnov statistic in continuous distributions. In this paper, we introduce a new test statistic for goodness of fit test which is based on entropy distance, and which can be applied for large sample sizes...

  11. Evaluation of field test equipment for halide and DOP testing

    International Nuclear Information System (INIS)

    Schreiber, K.L.; Kovach, J.L.

    1975-01-01

    The Nucon Testing Services Department, field testing at power reactor sites, has performed tests using R-11, R-12, and R-112 in conjunction with gas chromatographs and direct reading halide detectors. The field operational experience with these detector systems, thus sensitivity, precision, and manner of field calibration, are presented. Laboratory experiments regarding 3 H-tagged methyl iodide for in place leak testing of adsorber systems indicate a low hazard, high reliability process for leak testing in facilities where atmospheric cross contamination occurs. (U.S.)

  12. Test Review: Test of English as a Foreign Language[TM]--Internet-Based Test (TOEFL iBT[R])

    Science.gov (United States)

    Alderson, J. Charles

    2009-01-01

    In this article, the author reviews the TOEFL iBT which is the latest version of the TOEFL, whose history stretches back to 1961. The TOEFL iBT was introduced in the USA, Canada, France, Germany and Italy in late 2005. Currently the TOEFL test is offered in two testing formats: (1) Internet-based testing (iBT); and (2) paper-based testing (PBT).…

  13. Maximizing port and transportation system productivity by exploring alternative port operation strategies.

    Science.gov (United States)

    2011-06-01

    Seaports are a critical transportation component that supports the nations economy. Many U.S. : ports are now experiencing significant truck congestion at the gate, which decreases the productivity of : ports and truck fleets (e.g. truck wait time...

  14. A review of dry ports

    OpenAIRE

    Violeta Roso; Kent Lumsden

    2010-01-01

    The objective of this article is to present the previous research on the dry port concept and to review the world's existing dry ports, that is freight terminals that use the term ‘dry port’ in their name. Therefore, the purpose of this article is to clarify the concept by showing potential discrepancies or agreements between theory and practice. Starting from a literature review on the dry port concept, this article presents a review of existing dry ports in the world. A number of qualitativ...

  15. Helium Loop for the HCPB Test Blanket Module

    International Nuclear Information System (INIS)

    Neuberger, H.; Boccaccini, L.V.; Ghidersa, B. E.; Jin, X.; Meyder, R.

    2006-01-01

    In the frame of the activities of the EU Breeder Blanket Programme and of the Test Blanket Working Group, the Helium loop for the Helium Cooled Pebble Bed Test Blanket Module (HCPB-TBM) in ITER has been investigated with regard to the layout definition, selection of components, control, dimensioning and integration. This paper presents the status of development. The loop design for the HCPB-TBM in ITER will mainly base on the experience gained from Helium Loop Karlsruhe (HELOKA) which is currently developed at the FZK for experiments under ITER relevant conditions. The ITER loop will be equipped with similar components like HELOKA and will mainly consist of a circulator with variable speed drive, a recuperator, an electric heater, a cooler, a dust filter and auxilary components e.g. pipework and valves. A Coolant Purification System (CPS) and a Pressure Control System (PCS) are foreseen to meet the requirements on coolant conditioning. To prepare a TBM for a new experimental campaign, a succession of operational states like '' cold maintenance '', '' baking '' and '' cold standby '' is required. Before a pulse operation, a '' hot stand-by '' state should be achieved providing the TBM with inlet coolant at nominal conditions. This operation modus is continued in the dwell time waiting for the successive pulse. A '' tritium out-gassing '' will be also required after several TBM-campaigns to remove the inventory rest of T in the beds for measurement purpose. The dynamic circuit behaviour during pulses, transition between different operational states as well as the behaviour in accident situations are investigated with RELAP. The main components of the loop will be accommodated inside the Tokamak Cooling Water System(TCWS)- vault from where the pipes require connection to the TBM which is attached to port 16 of the vacuum vessel. Therefore pipes across the ITER- building of about 110 m in length (each) are required. Additional equipment is also located in the port cell

  16. Catecholamine blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003561.htm Catecholamine blood test To use the sharing features on this page, ... measured with a urine test than with a blood test. How the Test is Performed A blood sample ...

  17. Test facility TIMO for testing the ITER model cryopump

    International Nuclear Information System (INIS)

    Haas, H.; Day, C.; Mack, A.; Methe, S.; Boissin, J.C.; Schummer, P.; Murdoch, D.K.

    2001-01-01

    Within the framework of the European Fusion Technology Programme, FZK is involved in the research and development process for a vacuum pump system of a future fusion reactor. As a result of these activities, the concept and the necessary requirements for the primary vacuum system of the ITER fusion reactor were defined. Continuing that development process, FZK has been preparing the test facility TIMO (Test facility for ITER Model pump) since 1996. This test facility provides for testing a cryopump all needed infrastructure as for example a process gas supply including a metering system, a test vessel, the cryogenic supply for the different temperature levels and a gas analysing system. For manufacturing the ITER model pump an order was given to the company L' Air Liquide in the form of a NET contract. (author)

  18. Test facility TIMO for testing the ITER model cryopump

    International Nuclear Information System (INIS)

    Haas, H.; Day, C.; Mack, A.; Methe, S.; Boissin, J.C.; Schummer, P.; Murdoch, D.K.

    1999-01-01

    Within the framework of the European Fusion Technology Programme, FZK is involved in the research and development process for a vacuum pump system of a future fusion reactor. As a result of these activities, the concept and the necessary requirements for the primary vacuum system of the ITER fusion reactor were defined. Continuing that development process, FZK has been preparing the test facility TIMO (Test facility for ITER Model pump) since 1996. This test facility provides for testing a cryopump all needed infrastructure as for example a process gas supply including a metering system, a test vessel, the cryogenic supply for the different temperature levels and a gas analysing system. For manufacturing the ITER model pump an order was given to the company L'Air Liquide in the form of a NET contract. (author)

  19. Nondestructive Testing

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Harold [Argonne National Laboratory

    1969-01-01

    A nondestructive test is an examination of an object in any manner which will not impair the future usefulness of the object. This booklet discusses a few basic methods of nondestructive testing, and some of their characteristics. In addition, it discusses possible future methods for nondestructive testing by taking a quick look at some of the methods now under study.

  20. Science Library of Test Items. Volume Eleven. Mastery Testing Programme. [Mastery Tests Series 3.] Tests M27-M38.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 27 through 38 include: (27) reading a grid plan; (28) identifying common invertebrates; (29) characteristics of invertebrates; (30) identifying elements; (31) using scientific notation part I; (32) classifying minerals; (33) predicting the…

  1. Ground test facility for nuclear testing of space reactor subsystems

    International Nuclear Information System (INIS)

    Quapp, W.J.; Watts, K.D.

    1985-01-01

    Two major reactor facilities at the INEL have been identified as easily adaptable for supporting the nuclear testing of the SP-100 reactor subsystem. They are the Engineering Test Reactor (ETR) and the Loss of Fluid Test Reactor (LOFT). In addition, there are machine shops, analytical laboratories, hot cells, and the supporting services (fire protection, safety, security, medical, waste management, etc.) necessary to conducting a nuclear test program. This paper presents the conceptual approach for modifying these reactor facilities for the ground engineering test facility for the SP-100 nuclear subsystem. 4 figs

  2. High power RF test of an 805 MHz RF cavity for a muon cooling channel

    International Nuclear Information System (INIS)

    Li, Derun; Corlett, J.; MacGill, R.; Rimmer, R.; Wallig, J.; Zisman, M.; Moretti, A.; Qian, Z.; Wu, V.; Summers, D.; Norem, J.

    2002-01-01

    We present recent high power RF test results on an 805 MHz cavity for a muon cooling experiment at Lab G in Fermilab. In order to achieve high accelerating gradient for large transverse emittance muon beams, the cavity design has adopted a pillbox like shape with 16 cm diameter beam iris covered by thin Be windows, which are demountable to allow for RF tests of different windows. The cavity body is made from copper with stiff stainless steel rings brazed to the cavity body for window attachments. View ports and RF probes are available for visual inspections of the surface of windows and cavity and measurement of the field gradient. Maximum of three thermo-couples can be attached to the windows for monitoring the temperature gradient on the windows caused by RF heating. The cavity was measured to have Q 0 of about 15,000 with copper windows and coupling constant of 1.3 before final assembling. A 12 MW peak power klystron is available at Lab G in Fermilab for the high power test. The cavity and coupler designs were performed using the MAFIA code in the frequency and the time domain. Numerical simulation results and cold test measurements on the cavity and coupler will be presented for comparisons

  3. Thyroid Function Tests

    Science.gov (United States)

    ... Home » Thyroid Function Tests Leer en Español Thyroid Function Tests FUNCTION HOW DOES THE THYROID GLAND FUNCTION? ... Cancer Thyroid Nodules in Children and Adolescents Thyroid Function Tests Resources Thyroid Function Tests Brochure PDF En ...

  4. Blood sugar test

    Science.gov (United States)

    ... sugar; Blood sugar level; Fasting blood sugar; Glucose test; Diabetic screening - blood sugar test; Diabetes - blood sugar test ... The test may be done in the following ways: After you have not eaten anything for at least 8 ...

  5. Blood Test: Bilirubin

    Science.gov (United States)

    ... Videos for Educators Search English Español Blood Test: Bilirubin KidsHealth / For Parents / Blood Test: Bilirubin What's in ... liver or kidneys) is working. What Is a Bilirubin Test? A bilirubin test measures how much bilirubin ...

  6. Test Plan: WIPP bin-scale CH TRU waste tests

    International Nuclear Information System (INIS)

    Molecke, M.A.

    1990-08-01

    This WIPP Bin-Scale CH TRU Waste Test program described herein will provide relevant composition and kinetic rate data on gas generation and consumption resulting from TRU waste degradation, as impacted by synergistic interactions due to multiple degradation modes, waste form preparation, long-term repository environmental effects, engineered barrier materials, and, possibly, engineered modifications to be developed. Similar data on waste-brine leachate compositions and potentially hazardous volatile organic compounds released by the wastes will also be provided. The quantitative data output from these tests and associated technical expertise are required by the WIPP Performance Assessment (PA) program studies, and for the scientific benefit of the overall WIPP project. This Test Plan describes the necessary scientific and technical aspects, justifications, and rational for successfully initiating and conducting the WIPP Bin-Scale CH TRU Waste Test program. This Test Plan is the controlling scientific design definition and overall requirements document for this WIPP in situ test, as defined by Sandia National Laboratories (SNL), scientific advisor to the US Department of Energy, WIPP Project Office (DOE/WPO). 55 refs., 16 figs., 19 tabs

  7. Bacteria Culture Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/bacteriaculturetest.html Bacteria Culture Test To use the sharing features on this page, please enable JavaScript. What is a Bacteria Culture Test? Bacteria are a large group of ...

  8. Flu (Influenza) Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/fluinfluenzatest.html Flu (Influenza) Test To use the sharing features on this page, please enable JavaScript. What is a Flu (Influenza) Test? Influenza, known as the flu , is ...

  9. Allergy Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/allergybloodtest.html Allergy Blood Test To use the sharing features on this page, please enable JavaScript. What is an Allergy Blood Test? Allergies are a common and chronic ...

  10. STUDY OF EFFECTIVENESS OF BREAKWATER STRUCTURES OF THE “EASTERN PETROCHEMICAL COMPANY” JSC OIL REFINERY AND PETROCHEMICAL PLANTS PORT COMPLEX

    Directory of Open Access Journals (Sweden)

    Prikhod’ko Oleg Alekseevich

    2017-05-01

    Full Text Available The article presents the research of MGSU Corporation for testing of design solutions of the “Eastern petrochemical company” JSC oil refinery and petrochemical plants port complex using the physical modeling method. Construction of the marine terminal of the oil refinery and petrochemical plants port complex is planned to be on the Eastern shore of the Vostok Bay which is the part of Peter the Great Bay in the Sea of Japan. The port area is created by means of an artificial land site. The water area of the terminal will be guarded against sea waves by a breakwater. Experiments on the study of wave propagation in the port model water area at the Eastern and Western breakwaters were performed in the laboratory wave basin in three-dimensional layout, with the aim of obtaining of data about wave heights at berthing facilities. Effectiveness of the breakwater designs was studied in two-dimensional layout in a wave flume. During the port model construction all the designed waterworks as well as the project bathymetry of the port water area were reproduced at a scale of 1:100. Analysis of the experiment results with the slope protection embodiment version demonstrates that this engineering solution is able to withstand waves of the design parameters.

  11. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  12. Science Library of Test Items. Volume Ten. Mastery Testing Programme. [Mastery Tests Series 2.] Tests M14-M26.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 14 through 26 include: (14) calculating an average; (15) identifying parts of the scientific method; (16) reading a geological map; (17) identifying elements, mixtures and compounds; (18) using Ohm's law in calculation; (19) interpreting…

  13. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Georgeton, G.K.; Poirier, M.R.

    1990-01-01

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  14. Methodology for testing metal detectors using variables test data

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, D.D.; Murray, D.W.

    1993-08-01

    By extracting and analyzing measurement (variables) data from portal metal detectors whenever possible instead of the more typical ``alarm``/``no-alarm`` (attributes or binomial) data, we can be more informed about metal detector health with fewer tests. This testing methodology discussed in this report is an alternative to the typical binomial testing and in many ways is far superior.

  15. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  16. Advanced test reactor testing experience-past, present and future

    International Nuclear Information System (INIS)

    Marshall, Frances M.

    2006-01-01

    The Advanced Test Reactor (ATR), at the Idaho National Laboratory (INL), is one of the world's premier test reactors for providing the capability for studying the effects of intense neutron and gamma radiation on reactor materials and fuels. The physical configuration of the ATR, a 4-leaf clover shape, allows the reactor to be operated at different power levels in the corner 'lobes' to allow for different testing conditions for multiple simultaneous experiments. The combination of high flux (maximum thermal neutron fluxes of 1E15 neutrons per square centimeter per second and maximum fast [E>1.0 MeV] neutron fluxes of 5E14 neutrons per square centimeter per second) and large test volumes (up to 122 cm long and 12.7 cm diameter) provide unique testing opportunities. The current experiments in the ATR are for a variety of test sponsors - US government, foreign governments, private researchers, and commercial companies needing neutron irradiation services. There are three basic types of test configurations in the ATR. The simplest configuration is the sealed static capsule, which places the capsule in direct contact with the primary coolant. The next level of experiment complexity is an instrumented lead experiment, which allows for active control of experiment conditions during the irradiation. The most complex experiment is the pressurized water loop, in which the test sample can be subjected to the exact environment of a pressurized water reactor. For future research, some ATR modifications and enhancements are currently planned. This paper provides more details on some of the ATR capabilities, key design features, experiments, and future plans

  17. Analyzing Growth Opportunity of Port from the Resource-based Perspective The Case of Port of Tanjung Pelepas Malaysia

    Directory of Open Access Journals (Sweden)

    Muhammad Subhan

    2008-09-01

    Full Text Available Capturing growth opportunity has become a major integral activity of any port to sustain growth and competitive advantage. One of the famous strategies in leveraging sustainable growth and competitive advantage is the resource-based theory application into port strategic management, viewing resources of the port (internal and external and its capabilities as the sources for achieving competitive advantage. In this study, we attempt to identify, exploit, and analyze growth opportunity of a Malaysian port from the perspective of the theory. We analyze the port’s resources in terms of values, uniqueness, inimitability, durability, and substitutability. The result is then compared with its rival ports in the region. This study recognizes that the port has successfully identified and exploited its resources for capturing growth opportunity and competing with other ports in the region. We perceive that the port will sustain its growth and competitive advantage as a major port in the region based on its current performance and rivalry circumstances. This study signifies that the higher the level to which resource-based theory of competitive advantage is applied, the higher and longer the growth and competitive advantage will be achieved by the port.

  18. Implantable electrolyte conductance-based pressure sensing catheter, II. Device construction and testing.

    Science.gov (United States)

    Tan, Robert; Benharash, Peyman; Schulam, Peter; Schmidt, Jacob J

    2013-12-01

    Direct measurements of arterial blood pressure most commonly use bulky external instrumentation containing a pressure transducer connected to an ex vivo fluid-filled arterial line, which is subject to several sensing artifacts. In situ blood pressure sensors, typically solid state piezoresistive, capacitive, and interferometric sensors, are unaffected by these artifacts, but can be expensive to produce and miniaturize. We have developed an alternative approach to blood pressure measurement based on deformation of an elastic tube filled with electrolyte solution. Simple measurement of the electrical conductance of this solution as the tube dimensions change allows determination of the external pressure. The sensor is made from inexpensive materials and its miniaturization is straightforward. In vitro static testing of initial sensor prototypes mounted on a catheter tip showed a linear response with applied pressure and a resolution of 1 mmHg. In vivo sensing followed catheterization of the sensor into the femoral artery of a porcine model through a 7F catheter port. The sensor performed comparably to a commercial pressure transducer also connected to the catheter port. Due to its scalability and cost, this sensor has the potential for use in a range of pressure sensing applications, such as measurement of intracranial, spinal, or interstitial pressures.

  19. 46 CFR 57.06-2 - Production test plate interval of testing.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-2 Production test plate interval of testing. (a) At least one... 46 Shipping 2 2010-10-01 2010-10-01 false Production test plate interval of testing. 57.06-2... follows: (1) When the extent of welding on a single vessel exceeds 50 lineal feet of either or both...

  20. The Effect of Mini and Midi Anchor Tests on Test Equating

    Science.gov (United States)

    Arikan, Çigdem Akin

    2018-01-01

    The main purpose of this study is to compare the test forms to the midi anchor test and the mini anchor test performance based on item response theory. The research was conducted with using simulated data which were generated based on Rasch model. In order to equate two test forms the anchor item nonequivalent groups (internal anchor test) was…