WorldWideScience

Sample records for port system concentration

  1. ITER lower port systems integration

    Energy Technology Data Exchange (ETDEWEB)

    Levesy, B., E-mail: bruno.levesy@iter.org [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Baker, D.; Boussier, B.; Bryan, S.; Cordier, J.J.; Dremel, M.; Dell' Orco, G.; Daly, E.; Doshi, B.; Jeannoutot, T.; Friconneau, J.P.; Gliss, C.; Le Barbier, R.; Lachevre, F.; Loughlin, M.; Martin, A.; Martins, J.P.; Maruyama, S.; Palmer, J.; Reichle, R. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2011-10-15

    The lower port systems are installed inside the vacuum vessel lower ports and in the adjacent port cells. The vacuum vessel ports and penetrations are allocated as follow: -4 ports dedicated to remote handling of the divertor cassettes, contain diagnostics racks and divertor cooling pipes. -5 ports connecting the main vessel to the torus cryopumps, contain divertor cooling pipes, pellet and gas injection pipes and vertical stabilization coil feeders. -3 penetrations connecting torus cryopumps are connected to the vacuum vessel by branch pipes. -Specific penetrations for divertor cooling lines, in-vessel viewing and glow discharge systems. The general layout of the port systems has been revised recently to improve the cryopump (8 t weight, 1.8 m diameter and 2.5 m long) maintenance scheme with remote handling tools and integrate the in-vessel vertical stabilization coil feeders. The port allocation, the pumping ports design, and interfaces in-between ports and cryostat and in-between cryopumps and cryostat have been up-dated. The integration inside the 18 port cells (11 m x 4 m each) has been reviewed to avoid clashes in between systems and to fix the openings in the port cell concrete walls. The new layout integrates safety and neutron-shielding requirements as well as remote handling and maintenance compatibility for the different systems. The paper presents the up-dated integration of the lower port systems inside the ports and the port cells. Interfaces of the port systems with the vacuum vessel, the cryostat and the port cells are described.

  2. Systems theory of interconnected port contact systems

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; Schaft, A.J. van der

    2005-01-01

    Port-based network modeling of a large class of complex physical systems leads to dynamical systems known as port-Hamiltonian systems. The key ingredient of any port-Hamiltonian system is a power-conserving interconnection structure (mathematically formalized by the geometric notion of a Dirac

  3. Conservative systems with ports on contact manifolds

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; van der Schaft, Arjan; Piztek, P.

    In this paper we propose an extension of port Hamiltonian systems, called conservative systems with ports, which encompass systems arising from the Irreversible Thermodynamics. Firstly we lift a port Hamiltonian system from its state space manifold to the thermodynamic phase space to a contact

  4. Notch filters for port-Hamiltonian systems

    NARCIS (Netherlands)

    Dirksz, D.A.; Scherpen, J.M.A.; van der Schaft, A.J.; Steinbuch, M.

    2012-01-01

    In this paper a standard notch filter is modeled in the port-Hamiltonian framework. By having such a port-Hamiltonian description it is proven that the notch filter is a passive system. The notch filter can then be interconnected with another (nonlinear) port-Hamiltonian system, while preserving the

  5. Port-contact systems in bilateral telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2007-01-01

    In this paper we develop one of the first control applications of the recently proposed port-contact framework. We show how it is possible to model and control a bilateral telemanipulation system using port-contact systems and we develop a port-contact impedance controller that allows to impose a

  6. On Distributed Port-Hamiltonian Process Systems

    NARCIS (Netherlands)

    Lopezlena, Ricardo; Scherpen, Jacquelien M.A.

    2004-01-01

    In this paper we use the term distributed port-Hamiltonian Process Systems (DPHPS) to refer to the result of merging the theory of distributed Port-Hamiltonian systems (DPHS) with the theory of process systems (PS). Such concept is useful for combining the systematic interconnection of PHS with the

  7. Tsunami response system for ports in Korea

    Science.gov (United States)

    Cho, H.-R.; Cho, J.-S.; Cho, Y.-S.

    2015-09-01

    The tsunamis that have occurred in many places around the world over the past decade have taken a heavy toll on human lives and property. The eastern coast of the Korean Peninsula is not safe from tsunamis, particularly the eastern coastal areas, which have long sustained tsunami damage. The eastern coast had been attacked by 1983 and 1993 tsunami events. The aim of this study was to mitigate the casualties and property damage against unexpected tsunami attacks along the eastern coast of the Korean Peninsula by developing a proper tsunami response system for important ports and harbors with high population densities and high concentrations of key national industries. The system is made based on numerical and physical modelings of 3 historical and 11 virtual tsunamis events, field surveys, and extensive interviews with related people.

  8. Adaptive control of port-Hamiltonian systems

    NARCIS (Netherlands)

    Dirksz, D.A.; Scherpen, J.M.A.; Edelmayer, András

    2010-01-01

    In this paper an adaptive control scheme is presented for general port-Hamiltonian systems. Adaptive control is used to compensate for control errors that are caused by unknown or uncertain parameter values of a system. The adaptive control is also combined with canonical transformation theory for

  9. Port-Hamiltonian Systems on Open Graphs

    NARCIS (Netherlands)

    Schaft, A.J. van der; Maschke, B.M.

    2010-01-01

    In this talk we discuss how to define in an intrinsic manner port-Hamiltonian dynamics on open graphs. Open graphs are graphs where some of the vertices are boundary vertices (terminals), which allow interconnection with other systems. We show that a directed graph carries two natural Dirac

  10. Discrete port-Hamiltonian systems

    NARCIS (Netherlands)

    Talasila, V.; Clemente-Gallardo, J.; Schaft, A.J. van der

    2006-01-01

    Either from a control theoretic viewpoint or from an analysis viewpoint it is necessary to convert smooth systems to discrete systems, which can then be implemented on computers for numerical simulations. Discrete models can be obtained either by discretizing a smooth model, or by directly modeling

  11. Model reduction of port-Hamiltonian systems as structured systems

    NARCIS (Netherlands)

    Polyuga, R.V.; Schaft, van der A.J.

    2010-01-01

    The goal of this work is to demonstrate that a specific projection-based model reduction method, which provides an H2 error bound, turns out to be applicable to port-Hamiltonian systems, preserving the port-Hamiltonian structure for the reduced order model, and, as a consequence, passivity.

  12. A new system for port films.

    Science.gov (United States)

    Sephton, R; Green, M; Fitzpatrick, C

    1989-01-01

    A novel system for port films is described which incorporates a high-quality fluorescent screen lying behind a flat, heavy-metal screen or filter and the film pressed between them is not an X ray type but a single-emulsion, very high contrast graphics or line-type film. In experimental comparisons using 4 MV, 6 MV, and 25 MV photon beams, the new Peter MacCallum Cancer Institute (PMCI) system produced clearer images, about X2 higher in contrast yet lower in relative noise levels, than did the conventional commercially-available systems which use x-ray film between heavy-metal screens. Direct clinical comparisons, chiefly using 6 MV accelerators, confirmed that anatomical details were correspondingly better visualized and in general, the PMCI port film could be matched against the simulator radiograph with greater confidence. Routine use for greater than 2 yr in this Institute (4000 new patients per yr, 20 cassettes made for use with four 6 MV accelerators) has shown the PMCI system to be an economical and practical device, giving reproducibly high quality images in all the common port film applications.

  13. Managing Temporal Knowledge in Port Management Systems

    Directory of Open Access Journals (Sweden)

    Anita Gudelj

    2006-05-01

    Full Text Available Large ports need to deal with a number of disparate activities:the movement of ships, containers and other cargo, theloading and unloading of ships and containers, customs activities.As well as human resources, anchorages, channels, lighters,tugs, berths, warehouse and other storage spaces have to beallocated and released. The efficient management of a port involvesmanaging these activities and resources, managing theflows of money involved between the agents providing and usingthese resources, and providing management information.Many information systems will be involved.Many applications have to deal with a large amount of datawhich not only represent the perceived state of the real world atpresent, but also past and/or future states. These applicationsare not served adequately by today's computer managementand database systems. In particular, deletions and updates insuch systems have destructive semantics. This means that previousdatabase contents (representing previous perceived statesof the real world cannot be accessed anymore.A review of how define temporal data models, based ongeneralizing a non-temporal data model in to a temporal one toimprove port management is presented. This paper describes apractical experiment which supports managing temporal dataalong with the corresponding prototype implementations.

  14. System аnalysis concession maritime trade ports

    Directory of Open Access Journals (Sweden)

    Y.V. Shmatock

    2015-03-01

    Full Text Available The article proves the significance of maritime commercial ports as strategic for the country. The urgency of port concessions to improve transport infrastructure. The definition of ports in terms of system analysis and determination of management port. Outlined the sequence of system analysis concessions maritime trade ports in the table. Selection of qualified managers is based on the concession tender under prescribed conditions. These criteria should be considered when determining the concessionaire. These stages of the concession tender. Meeting the needs of the economy, international trade, public inquiries into transportation of goods is not possible without the efficient operation of maritime trade ports. Only complex technological modernization of maritime trade ports will enable them to take leadership positions. Tree depicted objectives effectively manage commercial sea port. Therefore, initiation of concessions needs to implement measures to achieve the talented and skillful result.

  15. Intra-arterial port implantation for intra-arterial chemotherapy : comparison between PIPS(Percutaneously Implantable Port System) and port system

    International Nuclear Information System (INIS)

    Yoon, Sang Jin; Shim, Hyung Jin; Jung, Hun Young; Choi, Yong Ho; Kim, Yang Soo; Song, In Sup; Kwak, Byung Kook

    1999-01-01

    To compare the techniques and complications of intra-arterial port implantation for intra-arterial chemotherapy between PIPS and the port system. For intra-arterial port implantation, 27 cases in 27 patients were retrospectively evaluated using PIPS(PIPS-200, William Cook Europe, Denmark) while for 21 cases in 19 patients a pediatric venous port system(Port-A-Cath, 5.8F, SIMS Deltec, U. S. A.) was used. All intra-arterial port implantation was performed percuteneously in an angiographic ward. Hepatocellular carcinoma was diagnosed in 18 patients and hepatic metastasis in 16. Peripheral cholangiocarcinoma, and pancreatic gastric, ovarian, renal cell and colon carcinoma were included. We compared the techniques and complications between PIPS and the port system. The follow up period ranged from 23 to 494(mean, 163) days in PIPS and from 12 to 431(mean, 150) days in the port system. In all cases, intra-arterial port implantations were technically successful. Port catheter tips were located in the common hepatic artery(n=8), proper hepatic artery(n=7), right hepatic artery(n=5), gastroduodenal artery(n=2), left hepatic artery(n=1), pancreaticoduodenal artery(n=1), inferior mesenteric artery(n=1), lumbar artery(n=1), and renal artery(n=1) in PIPS, and in the proper hepatic artery(n=6), gastroduodenal artery(n=6), common hepatic artery(n=3), right hepatic artery(n=4), inferior mesenteric artery(n=1), and internal iliac artery(n=1) in the port system. Port chambers were buried in infrainguinal subcutaneous tissue. Using PIPS, complications developed in seven cases(25.9%) and of these, four (57.1%) were catheter or chamber related. In the port system, catheter or chamber related complications developed in four cases(19.0%). Because PIPS and the port system have relative merits and demetrits, successful intra-arterial port implantation is possible if equipment is properly selected

  16. An integrated port camera and display system for laparoscopy.

    Science.gov (United States)

    Terry, Benjamin S; Ruppert, Austin D; Steinhaus, Kristen R; Schoen, Jonathan A; Rentschler, Mark E

    2010-05-01

    In this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD). Brightness, contrast, hue, colorfulness, and sharpness were compared. The port camera video is superior to the Storz scope and approximately equivalent to the Stryker scope. An ex vivo study was conducted to measure the operative performance of the port camera. The results suggest that simulated tissue identification and biopsy acquisition with the port camera is as efficient as with a traditional laparoscopic system. The port camera was successfully used by a laparoscopic surgeon for exploratory surgery and liver biopsy during a porcine surgery, demonstrating initial surgical feasibility.

  17. The Re-Conceptualization of the Port Supply Chain as a Smart Port Service System: The Case of the Port of Salerno

    Directory of Open Access Journals (Sweden)

    Antonio Botti

    2017-04-01

    Full Text Available This paper proposes a re-conceptualization of the port supply chain as a smart service system, in accordance with the theory of service science. Starting from a short literature review about the port supply chain approach and service science, a new comprehensive framework is provided to better understand seaport dynamics and the creation of competitive port supply chains. The methodology used is the case study approach. The Authors examined the Port of Salerno (Italy and re-conceptualized it as a smart port service system. The originality of the work lies in the application of service science as a lens to re-conceptualize the port supply chain, that allows the implementation of a logistic framework. Both theoretical and practical implications are provided to enrich the literature about port supply chains and to support port operators.

  18. Revealing the Linkage Network Dynamic Structures of Chinese Maritime Ports through Automatic Information System Data

    Directory of Open Access Journals (Sweden)

    Hongchu Yu

    2017-10-01

    Full Text Available Marine economic cooperation has emerged as a major theme in this era of globalization; hence, maritime network connectivity and dynamics have attracted more and more attention. Port construction and maritime route improvements increase maritime trade and thus facilitate economic viability and resource sustainability. This paper reveals the regional dimension of inter-port linkage dynamic structure of Chinese maritime ports from a complex multilayer perspective that is meaningful for strategic forecasting and regional long-term economic development planning. In this research, Automatic Information System (AIS-derived traffic flows were used to construct a maritime network and subnetworks based on the geographical locations of ports. The linkage intensity between subnetworks, the linkage tightness within subnetworks, the spatial isolation between high-intensity backbones and tight skeleton networks, and a linkage concentration index for each port were calculated. The ports, in turn, were analyzed based on these network attributes. This study analyzed the external competitiveness and internal cohesion of each subnetwork. The results revealed problems in port management and planning, such as unclear divisions in port operations. More critically, weak complementary relationships between the backbone and skeleton networks among the ports reduce connectivity and must be strengthened. This research contributes to the body of work supporting strategic decision-making for future development.

  19. Port Hamiltonian Formulation of Infinite Dimensional Systems I. Modeling

    NARCIS (Netherlands)

    Macchelli, Alessandro; Schaft, Arjan J. van der; Melchiorri, Claudio

    2004-01-01

    In this paper, some new results concerning the modeling of distributed parameter systems in port Hamiltonian form are presented. The classical finite dimensional port Hamiltonian formulation of a dynamical system is generalized in order to cope with the distributed parameter and multi-variable case.

  20. Three port converters used as interface in photovoltaic energy systems

    Directory of Open Access Journals (Sweden)

    Sarab Al-Chlaihawi

    2018-04-01

    Full Text Available The aim of this paper is to derive and study a full-bridge three-port converter. Based on the standard design of full-bridge converter, we have modeled and derived a three port converter. The three port converter can be used in renewable energy scenarios, such as solar cells or wind turbines connected to the input port. The input can be taken from two-ports simultaneously or from one port at a time. In order to balance the power mismatch between the input port and load port, the batteries are attached to the third port, to ensure there are no discrepancies in the power generated at the input and power demand at the load. In order to ensure isolation and reduced voltage stress on the switches, a high frequency transformer is also used in the design. The overall design contains four switches, and four diodes. MOSFETs are the strongest candidate for the switches owing to their high switching speed, lower losses and high resistance to higher voltage. Moreover, a buck-boost structure is modeled in order to ensure that it can work for a wide variety of different applications by adjusting the duty cycle of the switches properly. To minimize the switching losses in the converter, Zero-Voltage Switching (ZVS is also achievable in the modeled system.

  1. Port contact systems for irreversible thermodynamical systems

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; Schaft, A.J. van der

    2005-01-01

    In this paper we propose a definition of control contact systems, generalizing input-output Hamiltonian systems, to cope with models arising from irreversible Thermodynamics. We exhibit a particular subclass of these systems, called conservative, that leaves invariant some Legendre submanifold (the

  2. One-port portable SAW sensor system

    Science.gov (United States)

    Hoa Nguyen, Vu; Peters, Oliver; Schnakenberg, Uwe

    2018-01-01

    A portable device using the SAW-based impedance sensor type based on one interdigital transducer simultaneously as SAW generator and sensor element (1-port approach) is introduced. As a novelty, the so far required expensive vector network analyzer (VNA) is replaced by a hand-held device to measure the impedance spectrum of the SAW sensor by RF-gain-phase meters. Hence, some of the best features from the conventional oscillator and VNA approaches are combined to develop a low-cost and self-contained measurement system, including signal in- and output ability for real-time measurements. The pivotal aspect of the portable system is the transfer of the sophisticated high frequency approach into a quasi-static one. This enables the use of simple lumped electronics without the need of impedance matching circuits. Proof-of-concept was carried out by measuring conductivities of phosphate-buffered solutions and viscosities of glycerin. Sensitivities for temperature of 0.3%/°C, viscosity of 10.1% (mPa s)-1 and conductivity of 0.5% (S cm)-1 have been determined, respectively, which are competitive results compared to the benchmark approaches.

  3. Atmospherically deposited trace metals from bulk mineral concentrate port operations.

    Science.gov (United States)

    Taylor, Mark Patrick

    2015-05-15

    Although metal exposures in the environment have declined over the last two decades, certain activities and locations still present a risk of harm to human health. This study examines environmental dust metal and metalloid hazards (arsenic, cadmium, lead and nickel) associated with bulk mineral transport, loading and unloading port operations in public locations and children's playgrounds in the inner city of Townsville, northern Queensland. The mean increase in lead on post-play hand wipes (965 μg/m(2)/day) across all sites was more than 10-times the mean pre-play loadings (95 μg/m(2)/day). Maximum loading values after a 10-minute play period were 3012 μg/m(2), more than seven times the goal of 400 μg/m(2) used by the Government of Western Australia (2011). Maximum daily nickel post-play hand loadings (404 μg/m(2)) were more than 26 times above the German Federal Immission Control Act 2002 annual benchmark of 15 μg/m(2)/day. Repeat sampling over the 5-day study period showed that hands and surfaces were re-contaminated daily from the deposition of metal-rich atmospheric dusts. Lead isotopic composition analysis of dust wipes ((208)Pb/(207)Pb and (206)Pb/(207)Pb) showed that surface dust lead was similar to Mount Isa type ores, which are exported through the Port of Townsville. While dust metal contaminant loadings are lower than other mining and smelting towns in Australia, they exceeded national and international benchmarks for environmental quality. The lessons from this study are clear - even where operations are considered acceptable by managing authorities, targeted assessment and monitoring can be used to evaluate whether current management practices are truly best practice. Reassessment can identify opportunities for improvement and maximum environmental and human health protection. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Developing a testing tool for a port terminal operating system

    OpenAIRE

    Perič, Miran

    2011-01-01

    This thesis describes the approach for development of a testing tool which simulates the terminal operating system. Main result of the thesis is presentation of the approach for the development and operation of the application, which was developed in C# programming language. The application communicates with the port information system by messages exchange. Data is stored on a database. With the support of the application we can test the port information system before of future implem...

  5. Pulse mode counting system with parallel port interface

    International Nuclear Information System (INIS)

    Farooq, M.A.; Mushtaq, N.; Sultan, M.; Karim, A.

    2010-11-01

    Pulse mode Counting System (PPCS) module has been designed and developed which is compatible with SPP (Standard Parallel Port) and EPP Enhanced Parallel Port). This system can capture, present and store real time data in a well formatted form. The stored data is in a format that can be imported in different packages for further analysis. The purpose of this system is to facilitate the research experiments having frequency range up to 4 MHz and storing range up to 16 million counts. (author)

  6. Design and integration of lower ports for ITER diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Casal, Natalia, E-mail: Natalia.casal@iter.org [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Bertalot, Luciano; Cheng, Hao; Drevon, Jean Marc; Duckworth, Philip; Giacomin, Thibaud; Guirao, Julio; Iglesias, Silvia [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Kochergin, Mikhail [IOFFE Institute, Saint Petersburg (Russian Federation); Martin, Alex [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); McCarron, Eddie [Oxford Technologies Ltd., Abingdon (United Kingdom); Mokeev, Alexander [Russian Federation Domestic Agency, Moscow (Russian Federation); Mota, Fernando [CIEMAT, Madrid (Spain); Penot, Christophe; Portales, Mickael [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Kitazawa, Sin-iti [Japanese Domestic Agency, Naka (Japan); Sky, Jack [Oxford Technologies Ltd., Abingdon (United Kingdom); Suarez, Alejandro; Udintsev, Victor; Utin, Yuri [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); and others

    2015-10-15

    Highlights: • Lower port structures are in its conceptual design phase. • Electromagnetic and seismic loads, will dominate all other mechanical loads. • Design allows diagnostics support, neutron shielding while and signals transmission. • Installation and maintenance operations are fully remote handling compatible. - Abstract: All around the ITER vacuum vessel, forty-four ports will provide access to the vacuum vessel for remote handling operations, diagnostic systems, heating, and vacuum systems: 18 upper ports, 17 equatorial ports, and 9 lower ports. Among the lower ports, three of them will be used for the remote handling installation of the ITER divertor. Once the divertor is in place, these ports will host various diagnostic systems mounted in the so-called diagnostic racks. The diagnostic racks must allow the support and cooling of the diagnostics, extraction of the required diagnostic signals, and providing access and maintainability while minimizing the leakage of radiation toward the back of the port where the humans are allowed to enter. A fully integrated inner rack, carrying the near plasma diagnostic components, will be an stainless steel structure, 4.2 m long, with a maximum weight of 10 t. This structure brings water for cooling and baking at maximum temperature of 240 °C and provides connection with gas, vacuum and electric services. Additional racks (placed away from plasma and not requiring cooling) may be required for the support of some particular diagnostic components. The diagnostics racks and its associated ex vessel structures, which are in its conceptual design phase, are being designed to survive the lifetime of ITER of 20 years. This paper presents the current state of development including interfaces, diagnostic integration, operation and maintenance, shielding requirements, remote handling, loads cases and discussion of the main challenges coming from the severe environment and engineering requirements.

  7. On Interconnections of Infinite-dimensional Port-Hamiltonian Systems

    NARCIS (Netherlands)

    Pasumarthy, Ramkrishna; Schaft, Arjan J. van der

    2004-01-01

    Network modeling of complex physical systems leads to a class of nonlinear systems called port-Hamiltonian systems, which are defined with respect to a Dirac structure (a geometric structure which formalizes the power-conserving interconnection structure of the system). A power conserving

  8. On interconnections of infinite-dimensional port-Hamiltonian systems

    NARCIS (Netherlands)

    Ramkrishna Pasumarthy, R.P.; van der Schaft, Arjan

    2004-01-01

    Network modeling of complex physical systems leads to a class of nonlinear systems called port-Hamiltonian systems, which are defined with respect to a Dirac structure (a geometric structure which formalizes the power-conserving interconnection structure of the system). A power conserving

  9. Single-port laparoscopic myomectomy using a new single-port transumbilical morcellation system: initial clinical study.

    Science.gov (United States)

    Kim, Yong-Wook; Park, Byung-Joon; Ro, Duck-Yeong; Kim, Tae-Eung

    2010-01-01

    To evaluate the feasibility of single-port laparoscopic myomectomy with transumbilical morcellation and suturing. Continuing prospective study (Canadian Task Force classification II-3). University hospital. Fifteen patients who underwent single-port laparoscopic myomectomy between September 2008 and October 2009 to remove single or multiple uterine myomas, at least 1 in each patient measuring greater than 4 cm in diameter. All single-port laparoscopic myomectomy procedures were performed by a single surgeon (Dr. Y.W. Kim). Myomas were extracted transumbilically by cutting the myomas into smaller pieces with a knife or a conventional electromechanical morcellator. After making a single 1.5- to 2.0-cm umbilical incision, the single-port system, created with a wound retractor and a surgical glove, was inserted. All operations were performed using conventional rigid straight laparoscopic instruments. Laparoscopic suturing was performed in intramural myomas and some subserosal myomas. Patient mean (SD; range) age was 38.3 (5.6; 29-49) years. The number of myomas per patient was 1.6 (1.4; 1-6). The diameter of the largest myomas was 6.1 (1.5; 4.2-9.6) cm. In 4 patients, only a knife was required for transumbilical extraction of myomas, and in 11 patients, transumbilical morcellation with an electromechanical morcellator with or without a knife was used. Transumbilical drainage tubes were inserted into the pelvic cavity in 11 of 15 patients. Operative time was 96.7 (33.8; 35-150) minutes. The decrease in postoperative hemoglobin concentration was 1.8 (1.2; 0.4-3.6) g/dL. During the operations, no patients required blood transfusion. No patients developed postoperative fever. Neither bowel injury nor urinary tract injury occurred in any patient. The postoperative hospital stay was 3.1 (0.8; 2-4) days. Single-port transumbilical morcellation using a conventional electromechanical morcellator with or without a knife is feasible. Single-port laparoscopic myomectomy is an

  10. SYSTEMS FOR IMPROVEMENT OF BUSINESS INTEGRATED MANAGEMENT PROCESSES IN PORTS

    Directory of Open Access Journals (Sweden)

    Pavle Popovic

    2017-03-01

    Full Text Available Based on test results obtained so far, the objective relating to modern scientific methods and approaches has been defined with the intention to develop model which defines new management system integration model, by adopting necessary practical terms of real systems that most frequently circulate in maritime practice in the field of integrated management systems (IMS in terms of safety and security of vessels and ports. The subject of research is maritime, particularly port services, by way of defining internal and external advantages through adopting integrated management systems. The research will be conducted through theoretical and applied assessments of case study analyses using example of the Port of Kotor H.Co.

  11. Port-Hamiltonian approaches to motion generation for mechanical systems

    NARCIS (Netherlands)

    Sakai, Satoru; Stramigioli, Stefano

    This paper gives new motion generation methods for mechanical port-Hamiltonian systems. First, we propose a generation method based on an asymptotic stabilization method without damping assignment. This asymptotic stabilization method preserves the Hamiltonian structure in the closed-loop system

  12. Maximizing port and transportation system productivity by exploring alternative port operation strategies.

    Science.gov (United States)

    2011-06-01

    Seaports are a critical transportation component that supports the nations economy. Many U.S. : ports are now experiencing significant truck congestion at the gate, which decreases the productivity of : ports and truck fleets (e.g. truck wait time...

  13. Organizational and Managerial Structures, Financing and Other Elements of the Port System of Slovenia

    Directory of Open Access Journals (Sweden)

    Milojka Počuča

    2007-01-01

    Full Text Available The article gives a presentation of the port system of theRepublicof Slovenia and of the organizational, ownership andmanagerial structure of Slovenia's only cargo port in Koper.The analysis of the organizational, ownership and managerialstructure was carried out according to the methodology appliedin the European project entitled "Commission Staff WorkingProject on Public Financing and Charging Practices in theCommunity Sea Port Sector". The article performs a compara·tive analysis of the port of Koper with other ports of the EU inthe domain of organization, ownership and management, publicfinancing, accountancy monitoring of public money investedin the port infrastructure, principles of cost recovery ofinvested capital and possibilities of access of port operators tothe port infrastructure of the Slovenian cargo port. The articlepoints to the possibilities of ownership and managementchanges in the port of Koper.

  14. Discrete port-Hamiltonian systems : mixed interconnections

    NARCIS (Netherlands)

    Talasila, Viswanath; Clemente-Gallardo, J.; Schaft, A.J. van der

    2005-01-01

    Either from a control theoretic viewpoint or from an analysis viewpoint it is necessary to convert smooth systems to discrete systems, which can then be implemented on computers for numerical simulations. Discrete models can be obtained either by discretizing a smooth model, or by directly modeling

  15. Notch Filters for Port-Hamiltonian Systems

    NARCIS (Netherlands)

    Dirksz, Danny; Scherpen, Jacquelien M.A.; van der Schaft, Abraham J.; Steinbuch, Maarten

    Many powerful tools exist for control design in the frequency domain, but are theoretically only justified for linear systems. On the other hand, nonlinear control deals with control design methodologies that are theoretically justified for a larger and more realistic class of systems, but primarily

  16. [A new port catheter system of aluminum oxide ceramics].

    Science.gov (United States)

    Haindl, H; Schmoll, E; Willmann, G

    1995-03-01

    Implantable port catheter systems are becoming increasingly important, as they often permit out-patient treatment for many indications that would otherwise require hospitalization. Moreover, they also increase the safety/reliability of infusion therapy in critical inpatients. For a variety of reasons, the materials used so far, i.e. steel, titanium and various plastics have not been completely satisfactory. The main disadvantage of metallic systems is the formation of artefacts in tomographic images, while the shortcomings of plastics are mechanical, e.g. chip formation and early membrane failure. Against this background, a port catheter system made of alumina ceramic, which is largely free of the disadvantages of the other materials, was developed. The expected advantages in terms of complication rate and radiological artefacts, were fully confirmed by the evaluation of 160 monitored patients.

  17. Solar cell concentrating system

    International Nuclear Information System (INIS)

    Garg, H.P.; Sharma, V.K.; Agarwal, R.K.

    1986-11-01

    This study reviews fabrication techniques and testing facilities for different solar cells under concentration which have been developed and tested. It is also aimed to examine solar energy concentrators which are prospective candidates for photovoltaic concentrator systems. This may provide an impetus to the scientists working in the area of solar cell technology

  18. Linear Port-Hamiltonian Systems on Infinite-dimensional Spaces

    CERN Document Server

    Jacob, Birgit

    2012-01-01

    This book provides a self-contained introduction to the theory of infinite-dimensional systems theory and its applications to port-Hamiltonian systems. The textbook starts with elementary known results, then progresses smoothly to advanced topics in current research. Many physical systems can be formulated using a Hamiltonian framework, leading to models described by ordinary or partial differential equations. For the purpose of control and for the interconnection of two or more Hamiltonian systems it is essential to take into account this interaction with the environment. This book is the fir

  19. Determination of radionuclide concentration of landfill at Eliozu, Port Harcourt, Rivers State

    International Nuclear Information System (INIS)

    Avwiri, G.O.; Nte, F.U.; Olanrewaju, A.I.

    2011-01-01

    A survey of the radionuclide concentration from landfill around Eliozu in Port-Harcourt area of River State has been carried out. This study assessed the level of terrestrial gamma radiation and associated dose rates from the naturally occurring radionuclide: 232 Th, 238 U and 40 K. 10 soil and 10 water samples collected from the respective reclaimed part of the Eliozu landfill were analyzed using the gamma-ray spectrometry Nal(TI) detector system. The mean activity concentration for soil was found to be 27.41±9.97Bq/kg for 238 U, 19.27±8.14 Bq/Kg for 232 Th and 326.08±66.74Bq/Kg for 40 K. The average specific activity concentration obtained for 238 U, 232 Th, 40 K for the water samples were 7.92±2.69Bq/l, 6.96±2.37Bq/l and 24.77±8.33 Bq/l. Absorbed dose rates in air outdoors were calculated to be between the range of 23.53nGy.h -1 and 50.39nGy.h -1 with a mean of 38.17±12.45nGy.h -1 for soil and between the range of 6.62nGy.h -1 and 10.71nGy.h -1 with a mean 9.03±3.07nGy.h -1 for water. This value is less than the world average of 55nGy.h -1 for soil. Inhabitants around the landfill are subjected to equivalent radiation exposure (effective dose rate) ranging between 0.2061 and 0.4414mSv.y -1 with a mean of 0.3344±0.1091mSv.y -1 and ranging between 0.0580 and 0.0938mSv.y -1 with a mean of 0.0791±0.0269mSv.y -1 for soil and water. The results comparable to those reported for environment in Nigeria and the world is relatively high due to the presence of medical wastes co-disposed with other wastes in these areas. The results indicated that the observed radiation dose of the terrestrial soils and water from Eliozu reclaimed landfill is minimal and seem to have no high exposure for either inhabitant in and around the landfill.

  20. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (porting). Progress report fiscal 1996

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Toshiyuki [Fujitsu Ltd., Tokyo (Japan); Kawasaki, Nobuo; Tanabe, Hidenobu [and others

    1998-01-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the porting. In this porting part, the porting of reactor safety analysis code RELAP5/MOD3.2 and RELAP5/MOD3.2.1.2, nuclear data processing system NJOY and 2-D multigroup discrete ordinate transport code TWOTRAN-II are described. And also, a survey for the porting of command-driven interactive data analysis plotting program IPLOT are described. In the parallelization part, the parallelization of 2-Dimensional relativistic electromagnetic particle code EM2D, Cylindrical Direct Numerical Simulation code CYLDNS and molecular dynamics code for simulating radiation damages in diamond crystals DGR are described. And then, in the vectorization part, the vectorization of two and three dimensional discrete ordinates simulation code DORT-TORT, gas dynamics analysis code FLOWGR and relativistic Boltzmann-Uehling-Uhlenbeck simulation code RBUU are described. (author)

  1. ORGANIZATION AND IMPLEMENTATION OF INTEGRATED MANAGEMENT SYSTEM PROCESSES - CRUISE PORT DUBROVNIK

    Directory of Open Access Journals (Sweden)

    Ivona Vrdoljak Raguz

    2012-01-01

    Full Text Available World cruise market is very dynamic and it is characterised by constant changes in offer and demand. Dubrovnik, as one of the leading port in the Mediterranean is faced with the problem of large concentrations of ships and passengers in a short period of time. Paper provides answers to the questions: how to manage cruise tourism in Dubrovnik? What are the guidelines for the further development of cruising in Dubrovnik? Modern ports management system must be organized and managed in a manner that will ensure the recognition requirements of stakeholders and their fulfilment. All this requires a more complex integrated management system, in which the requirements of quality management will be the basis, and requirements of environmental management needed an upgrade.

  2. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (porting). Progress report fiscal 1997

    International Nuclear Information System (INIS)

    Ishizuki, Shigeru; Nemoto, Toshiyuki; Kawai, Wataru; Watanabe, Hideo; Tanabe, Hidenobu; Kawasaki, Nobuo; Adachi, Masaaki; Ogasawara, Shinobu; Kume, Etsuo

    1999-05-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system and/or the AP3000 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 14 codes in fiscal 1997. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the porting. In this porting part, the porting of transient reactor analysis code TRAC-BF1 and Monte Carlo radiation transport code MCNP4A on the AP3000 are described. In addition, a modification of program libraries for command-driven interactive data analysis plotting program IPLOT is described. In the vectorization part, the vectorization of multidimensional two-fluid model code ACE-3D for evaluation of constitutive equations, statistical decay code SD and three-dimensional thermal analysis code for in-core test section (T2) of HENDEL SSPHEAT are described. In the parallelization part, the parallelization of cylindrical direct numerical simulation code CYLDNS44N, worldwide version of system for prediction of environmental emergency dose information code WSPEEDI, extension of quantum molecular dynamics code EQMD and three-dimensional non-steady compressible fluid dynamics code STREAM are described. (author)

  3. Cask and plug handling system design in port cell

    International Nuclear Information System (INIS)

    Martins, Jean-Pierre; Friconneau, Jean-Pierre; Gabellini, Eros; Keller, Delphine; Levesy, Bruno; Selvi, Anna; Tesini, Alessandro; Utin, Yuri; Wagrez, Julien

    2011-01-01

    The ITER maintenance strategy relies partly on the remote transfer of components from vacuum vessel to hot cells. This function will be fulfilled by transfer cask systems. This paper describes the recent design progresses on interfaces in order to increase components handling feasibility by implementing continuous guiding features that avoid cantilevered loads on the in-cask tractor. Also the design has progressed in order to allow generic docking of the casks. When the cask is connected to the port, it becomes part of the machine first confinement boundary, thus it must provide tightness continuity. This high level safety function was one of the main concerns of a finite element analysis study that has been performed to assess the behavior of the whole system. Numerical analysis methodology and results are explained and shown in order to highlight how it has reinforced the knowledge of the system.

  4. Implementation of Bluetooth serial port based profiles in embedded systems

    Science.gov (United States)

    Liu, Guanglei; Qiu, Zhengding; Wang, Quanping; Gao, Qiang

    2001-10-01

    Bluetooth is a new short-range wireless communication technology developing rapidly in recent years. Bluetooth software architecture consists of stack and profiles. Serial Port Profile (SPP) is an underlying profile that emulates RS232 serial cable connections between two peer devices. Based on SPP, Dial-up Networking (DUN) Profile establishes PPP connection with remote dial-up server, Fax Profile realizes document facsimile function and LAN Access Profile (LAP) provides local area network access service. When it comes to their implementation in embedded systems, there are several challenges such as memory consumption, code efficiency, code reliability, and code portability onto different OS and hardware platforms to be attacked. In this paper, we propose integrated software architecture after discussing the great similarities shared among the three SPP based profiles. Then implementation of the architecture is given, in which OS-dependent and OS-independent parts are clearly separated. Profile interfaces with stack and OS are specified respectively so that the three profiles as a whole can be ported onto various software and hardware platforms easily. As a result, policy of transplanting our implementation onto different platforms is addressed at the end of the paper.

  5. Concentrating Solar Power Systems

    Science.gov (United States)

    Pitz-Paal, R.

    2017-07-01

    Development of Concentrating Solar Power Systems has started about 40 years ago. A first commercial implementation was performed between 1985 and 1991 in California. However, a drop in gas prices caused a longer period without further deployment. It was overcome in 2007 when new incentive schemes for renewables in Spain and the US enabled a commercial restart. In 2016, almost 100 commercial CSP plants with more than 5GW are installed worldwide. This paper describes the physical background of CSP technology, its technical characteristics and concepts. Furthermore, it discusses system performances, cost structures and the expected advancement.

  6. A port-Hamiltonian approach to visual servo control of a pick and place system

    NARCIS (Netherlands)

    Dirksz, Daniel A.; Scherpen, Jacquelien M.A.

    2012-01-01

    In this paper we take a port-Hamiltonian approach to address the problem of image-based visual servo control of a pick and place system. We realize a closed-loop system, including the nonlinear camera dynamics, which is port-Hamiltonian. Although the closed-loop system is nonlinear, the resulting

  7. Data on metals (Zn, Al, Sr, and Co and metalloid (As concentration levels of ballast water in commercial ships entering Bushehr port, along the Persian Gulf

    Directory of Open Access Journals (Sweden)

    Farshid Soleimani

    2016-12-01

    Full Text Available In this article, we determined the concentration levels of metals including Zn, Al, Sr, and Co and metalloid of As of ballast water in commercial ships entering Bushehr port, along the Persian Gulf. Ballast water samples were taken from commercial ships entering Bushehr port from 34 ports around the world during 15 February and 25 August 2016. The concentration levels of metals and metalloid were determined by using a graphite furnace absorption spectrometer (AAS.

  8. Agile Port System Transition Support Transition Plan Development

    Science.gov (United States)

    2013-07-29

    the term agile port like  coca   cola  having migrated to the national lexicon in ubiquitous general usage.  For its part the JDDSP concept has evolved...RTLS technology is a COTS patented technology and TrAMS technology is owned by CSUOB  Foundation. Neither is in a  financial  position to invest in...acquisition and  systems engineering principles.   Cost    X    A focused effort would require dedication of adequate in kind and  financial  DoD resources

  9. A cost-effective peripheral venous port system placed at the bedside.

    Science.gov (United States)

    Finney, R; Albrink, M H; Hart, M B; Rosemurgy, A S

    1992-07-01

    High costs and a paucity of available operating time have led us to seek alternatives to operatively placed vascular access systems. This prospective study is the initial report of a peripheral port system (P.A.S. PORT System, Pharmacia Deltec, Inc.) placed at the bedside. Seventy-nine patients (52 male, 27 female), ages 3-92 years, had ports implanted by surgical residents with attending supervision. Sixty-eight (86%) received the P.A.S. PORT for long-term antibiotics, antifungal, or antiviral therapy; four (5%) for TPN infusion; three (4%) for blood products; two (3%) for chemotherapy; and two (3%) for iv narcotics. Ports were placed in 10 (13%) HIV(+) patients, three (4%) who were fully anticoagulated, and one who was a hemophiliac with a platelet count of zero. Eight patients (10%) developed superficial phlebitis, all of which resolved with nonsteroidal anti-inflammatory agents within 48 hr without port removal. Seven patients (9%) had their port removed due to infection. The average hospital charge to place the P.A.S. PORT System was $1488.00 vs $2811.00 for a tunneled external chest catheter and $3729.00 for the placement of a chest port. Bedside insertion of vascular access devices can be safely performed with acceptable infection rates allowing more efficient use of hospital operating rooms and with substantial cost savings.

  10. Tritium and heat management in ITER Test Blanket Systems port cell for maintenance operations

    Energy Technology Data Exchange (ETDEWEB)

    Giancarli, L.M., E-mail: luciano.giancarli@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Cortes, P.; Iseli, M.; Lepetit, L.; Levesy, B. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Livingston, D. [Frazer-Nash Consultancy Ltd., Stonebridge House, Dorking Business Park, Dorking, Surrey RH4 1HJ (United Kingdom); Nevière, J.C. [Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Pascal, R. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Ricapito, I. [Fusion for Energy, Josep Pla, 2, Torres Diagonal Litoral B3, Barcelona E-08019 (Spain); Shu, W. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Wyse, S. [Frazer-Nash Consultancy Ltd., Stonebridge House, Dorking Business Park, Dorking, Surrey RH4 1HJ (United Kingdom)

    2014-10-15

    Highlights: •The ITER TBM Program is one of the ITER missions. •We model a TBM port cell with CFD to optimize the design choices. •The heat and tritium releases management in TBM port cells has been optimized. •It is possible to reduce the T-concentration below one DAC in TBM port cells. •The TBM port cells can have human access within 12 h after shutdown. -- Abstract: Three ITER equatorial port cells are dedicated to the assessment of six different designs of breeding blankets, known as Test Blanket Modules (TBMs). Several high temperature components and pipework will be present in each TBM port cell and will release a significant quantity of heat that has to be extracted in order to avoid the ambient air and concrete wall temperatures to exceed allowable limits. Moreover, from these components and pipes, a fraction of the contained tritium permeates and/or leaks into the port cell. This paper describes the optimization of the heat extraction management during operation, and the tritium concentration control required for entry into the port cell to proceed with the required maintenance operations after the plasma shutdown.

  11. Dual temperature concentration system

    International Nuclear Information System (INIS)

    Spevack, J.S.

    1975-01-01

    In a dual temperature isotope exchange system--exemplified by exchange of deuterium and protium between water and hydrogen sulfide gas in hot and cold towers, in which the feed stream (water) containing the desired isotope is passed through a pair of towers maintained at different temperatures wherein it effects isotope exchange with countercurrently circulated auxiliary fluid (H 2 S) and is impoverished in said isotope and then disposed of, e.g. discharged to waste,--the flow of isotope enriched auxiliary fluid between said towers (hot H 2 S saturated with water vapor) is divided and a part thereof is adjusted in its temperature (to cold tower conditions) and then passed to the auxiliary fluid impoverishing (cold) tower, while the remainder of the divided flow of such enriched auxiliary fluid is passed through a subsequent isotope concentration treatment to produce a product more highly enriched in the desired isotope and wherein it is also adjusted in its temperature and is impoverished in said isotope during said subsequent treatment before it is delivered to the said auxiliary fluid impoverishing (cold) tower. Certain provisions are made for returning to the hot tower liquid carried as vapor by the remainder of the divided flow to the subsequent isotope concentration treatment, for recovering sensible and latent heat, and for reducing passage of auxiliary fluid to waste

  12. Analysis of the role of port labour systems and reforms on the ...

    African Journals Online (AJOL)

    Analysis of the role of port labour systems and reforms on the competitiveness of ... Outline: - The study as a matter of order, presents as an introduction, the ... can play in the performance of a port, is presented using Ghana as a case study.

  13. [Attempt to reduce the formaldehyde concentration by blowing cooled fresh air down in to the breathing zone of medical students from an admission port on the ceiling during gross anatomy class].

    Science.gov (United States)

    Takayanagi, Masaaki; Sakai, Makoto; Ishikawa, Youichi; Murakami, Kunio; Kimura, Akihiko; Kakuta, Sachiko; Sato, Fumi

    2008-09-01

    Cadavers in gross anatomy laboratories at most medical schools are conventionally embalmed in formaldehyde solution, which is carcinogenic to humans. Medical students and instructors are thus exposed to formaldehyde vapors emitted from cadavers during dissection. To reduce high formaldehyde concentrations in the breathing zone above cadavers being examined by anatomy medical students provisionally, dissection beds were located under existing admission ports on the ceiling to supply cooled fresh air from the admission port blowing downward on to the cadaver. In all cases, compared to normal condition, the downward flow of cooled fresh air from an admission port reduced formaldehyde concentrations by 0.09-0.98 ppm and reduced to 12.6-65.4% in the air above a cadaver in the breathing zone of students. The formaldehyde concentrations above cadavers under admission ports were not more than the formaldehyde concentrations between beds representing the indoor formaldehyde concentrations. Although the application of an existing admission port on the ceiling in this study did not remove formaldehyde, the downflow of cooled fresh air using this system reduced the formaldehyde concentration in the air above cadavers being attended by anatomy students during dissections. These results suggest the need for reducing formaldehyde levels in gross anatomy laboratories using fundamental countermeasures in order to satisfy the guidelines of 0.08 ppm established by the World Health Organization and the Japan Ministry of Health, Labor and Welfare.

  14. A Multi-Agent System for Tracking the Intent of Surface Contacts in Ports and Waterways

    National Research Council Canada - National Science Library

    Tan, Kok S

    2005-01-01

    ...) and employ them to identify asymmetric maritime threats in port and waterways. Each surface track is monitored by a compound multi-agent system that comprise of the several intent models, each containing a nested multi-agent system...

  15. A Comparison of Clinical Outcomes with Regular- and Low-Profile Totally Implanted Central Venous Port Systems

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Steitparth, Florian; Cho, Chie Hee; Benter, Thomas; Gebauer, Bernhard

    2009-01-01

    The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 ± 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 ± 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.

  16. Concept development for the ITER equatorial port visible/infrared wide angle viewing system

    International Nuclear Information System (INIS)

    Reichle, R.; Beaumont, B.; Boilson, D.; Bouhamou, R.; Direz, M.-F.; Encheva, A.; Henderson, M.; Kazarian, F.; Lamalle, Ph.; Lisgo, S.; Mitteau, R.; Patel, K. M.; Pitcher, C. S.; Pitts, R. A.; Prakash, A.; Raffray, R.; Schunke, B.; Snipes, J.; Diaz, A. Suarez; Udintsev, V. S.

    2012-01-01

    The ITER equatorial port visible/infrared wide angle viewing system concept is developed from the measurement requirements. The proposed solution situates 4 viewing systems in the equatorial ports 3, 9, 12, and 17 with 4 views each (looking at the upper target, the inner divertor, and tangentially left and right). This gives sufficient coverage. The spatial resolution of the divertor system is 2 times higher than the other views. For compensation of vacuum-vessel movements, an optical hinge concept is proposed. Compactness and low neutron streaming is achieved by orienting port plug doglegs horizontally. Calibration methods, risks, and R and D topics are outlined.

  17. Sampled Data Systems Passivity and Discrete Port-Hamiltonian Systems

    NARCIS (Netherlands)

    Stramigioli, Stefano; Secchi, Cristian; Schaft, Arjan J. van der; Fantuzzi, Cesare

    2005-01-01

    In this paper, we present a novel way to approach the interconnection of a continuous and a discrete time physical system. This is done in a way which preserves passivity of the coupled system independently of the sampling time T. This strategy can be used both in the field of telemanipulation, for

  18. Correlations between atmospheric aerosol trace element concentrations and red tide at Port Aransas, Texas, on the Gulf of Mexico

    International Nuclear Information System (INIS)

    Biegalski, S.R.; Villareal, T.A.

    2005-01-01

    Neutron activation analysis (NAA) was employed as an analytical technique to measure atmospheric aerosol concentrations of trace metals in Port Aransas, TX on the Gulf of Mexico. The sources of atmospheric aerosols and the seasonal variation of the sources are explored. High atmospheric iron concentrations are then shown to have a possible correlation to the occurrences of red tide in this region. The data shows that this correlation is plausible, but due to the many factors that affect red tide growth a definitive conclusion may not be reached. The period of study for these measurements was September 12, 2000 to January 4, 2002. (author)

  19. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  20. A fuzzy TOPSIS model to evaluate the Business Intelligence competencies of Port Community Systems

    Directory of Open Access Journals (Sweden)

    Ghazanfari Mehdi

    2014-04-01

    Full Text Available Evaluation of the Business Intelligence (BI competencies of port community systems before they are bought and deployed is a vital importance for establishment of a decision-support environment for managers. This study proposes a new model which provides a simple approach to the assessment of the BI competencies of port community systems in organization. This approach helps decision-makers to select an enterprise system with appropriate intelligence requirements to support the managers’ decision-making tasks. Thirtyfour criteria for BI specifications are determined from a thorough review of the literature. The proposed model uses the fuzzy TOPSIS technique, which employs fuzzy weights of the criteria and fuzzy judgments of port community systems to compute the evaluation scores and rankings. The application of the model is realized in the evaluation, ranking and selecting of the needed port community systems in a port and maritime organization, in order to validate the proposed model with a real application. With utilizing the proposed model organizations can assess, select, and purchase port community systems which will provide a better decision-support environment for their business systems.

  1. Evaluation of the boundary condition influence on PAH concentrations in the water column during the sediment dredging of a port.

    Science.gov (United States)

    Cutroneo, L; Castellano, M; Carbone, C; Consani, S; Gaino, F; Tucci, S; Magrì, S; Povero, P; Bertolotto, R M; Canepa, G; Capello, M

    2015-12-30

    The mobilisation of sediments and related contaminants connected to dredging activities is one of the most critical issues to the environmental risk and exposure assessment of a dredging project. The aim of this paper was an investigation of the mobilisation of polycyclic aromatic hydrocarbons (PAHs) due to the dredging of the Port of Genoa (Italy) to identify the temporal and spatial extent of the contaminant transport, and the influence of the dredging and the boundary conditions on it. The results showed relatively low background PAH concentrations in the water column and confirmed the dredging as the primary rising factor of concentrations in the water column, but also showed a complex scenario in which the different environmental and dredging factors forced the concentrations at different levels and moments. The post dredging phase showed PAH values close to the background conditions and the concentrations remained relatively high only for a few PAHs.

  2. RESEARCH ON THE LEGAL PROBLEMS OF THE PORT MANAGEMENT SYSTEM IN JAPAN

    OpenAIRE

    TAKAHASHI, Koji; KASUGAI, Yasuo; FUKUDA, Isao

    2014-01-01

    Across the world, port management is increasingly adopting a scheme of separatinginfrastructure and operations. In the midst of this global trend, Japan experienced the Great Hanshin andAwaji Earthquake in 1995 and the Great East Japan Earthquake in 2011, both of which devastated majorports, forcing Japan to face challenges related to its port management system. In addition, with majorearthquakes expected to strike again in the future, it is urgent for Japan to solve the current problems. Jap...

  3. Management of Port Operations

    OpenAIRE

    Gheorghe BASANU; Georgiana NUKINA

    2011-01-01

    The Management of port operation requires the proper and efficient use of port facility, equipment for cargo handling, berth facilities, waterways and roads. It also entails the use of effective communications system, storage facilities, and dockworkers. The whole activities mentioned above form the bulk of port operations. The aspiration of port operator is to get cargo through the gateway of ports as fast as possible on to other modes of transport (rail or road) with a minimal cost to them ...

  4. Optimal concentrations in transport systems

    Science.gov (United States)

    Jensen, Kaare H.; Kim, Wonjung; Holbrook, N. Michele; Bush, John W. M.

    2013-01-01

    Many biological and man-made systems rely on transport systems for the distribution of material, for example matter and energy. Material transfer in these systems is determined by the flow rate and the concentration of material. While the most concentrated solutions offer the greatest potential in terms of material transfer, impedance typically increases with concentration, thus making them the most difficult to transport. We develop a general framework for describing systems for which impedance increases with concentration, and consider material flow in four different natural systems: blood flow in vertebrates, sugar transport in vascular plants and two modes of nectar drinking in birds and insects. The model provides a simple method for determining the optimum concentration copt in these systems. The model further suggests that the impedance at the optimum concentration μopt may be expressed in terms of the impedance of the pure (c = 0) carrier medium μ0 as μopt∼2αμ0, where the power α is prescribed by the specific flow constraints, for example constant pressure for blood flow (α = 1) or constant work rate for certain nectar-drinking insects (α = 6). Comparing the model predictions with experimental data from more than 100 animal and plant species, we find that the simple model rationalizes the observed concentrations and impedances. The model provides a universal framework for studying flows impeded by concentration, and yields insight into optimization in engineered systems, such as traffic flow. PMID:23594815

  5. Tools for an integrated systems approach to sustainable port city planning

    Directory of Open Access Journals (Sweden)

    Gilles Morel

    2013-12-01

    Full Text Available Large port cities like Shanghai, Amsterdam and Rio de Janeiro are key cogwheels in international logistics and transport networks but also serve as showcases for the rest of the world; as such, they constitute strategic assets for the host country´s economy and international influence. Historically, a city and its port often developed independently, through sometimes contradictory or even confrontational policies. Today, the growing number of usage disputes over increasingly coveted coastal areas is prompting local managers to incorporate urban and port-related issues in overarching planning programs. In particular, planning of the sea front and the buffer zone between the port and the city must contribute decisively to the deployment of more effective, cleaner transport services for the port city as a whole. In general, one of the key global challenges for planners and decision-makers consists in integrating sustainable development goals (environmental and social components, as well as the stimulation of industrial competitiveness into urban planning. In this context the PHEBUS research group has initiated an international program of research to develop innovative methods and tools that can help territorial stakeholders to design, evaluate, compare and ultimately choose development scenarios for the future of their port cities. The main themes are addressed via a multidisciplinary systems approach on the scale of a coastal urban area with an industrial and port complex. In particular, the themes include sea front planning, the city-port interface, energy optimization (e.g. the introduction and sharing of renewable energies, risk resilience, climate change and multimodal, clean transport.

  6. Asymptotic Stabilization of Non-holonomic Port-controlled Hamiltonian Systems

    DEFF Research Database (Denmark)

    Sørensen, Mathias Jesper; Bendtsen, Jan Dimon; Andersen, Palle

    2004-01-01

    A novel method for asymptotic stabilization of a class of non-holonomic systems is presented. The method is based on the port-controlled Hamiltonian description of electro-mechanical systems. The general system is augmented with so-called kinematic inputs, thus representing a special class of mob...

  7. A Port-Hamiltonian Approach to Visual Servo Control of a Pick and Place System

    NARCIS (Netherlands)

    Dirksz, Daniel A.; Scherpen, Jacquelien M. A.; Steinbuch, Maarten

    In this paper, we take a port-Hamiltonian approach to address the problem of image-based visual servo control of a pick and place system. Through a coordinate transformation and a passive interconnection between mechanical system and camera dynamics we realize a closed-loop system that is

  8. Integrated model of port oil piping transportation system safety including operating environment threats

    OpenAIRE

    Kołowrocki, Krzysztof; Kuligowska, Ewa; Soszyńska-Budny, Joanna

    2017-01-01

    The paper presents an integrated general model of complex technical system, linking its multistate safety model and the model of its operation process including operating environment threats and considering variable at different operation states its safety structures and its components safety parameters. Under the assumption that the system has exponential safety function, the safety characteristics of the port oil piping transportation system are determined.

  9. Efficiency Comparison between Conventional and Modern Port Operation System for Small-Scale Dry Bulk Cargo

    Directory of Open Access Journals (Sweden)

    Tiara Aulia

    2018-01-01

    Full Text Available Since the launching of Sea Toll Road Program in 2015, the improvement in ports’ operation systems has become Indonesia’s foremost necessity. This improvement commonly leads to equipment modernization, while realistically, modern equipment does not always amount to a productive performance, especially in the context of small-scale ports. Instead, it is prone to creating wasteful capital and maintenance cost as well as making the planning time ineffective. This study compares two options of port operation systems in a small port, which is conventional and technologically-advanced method for dry bulk cargo. It results in thin gaps between each option’s financial assessment variables, which are Internal Rate of Return, Benefit/Cost Ratio and Payback Period, regardless of a stark difference between each option’s equipment cost. This study concludes that with the right approach, the conventional operation system is still the most efficient option compared to its contemporary opposite.

  10. Design analysis and comparison between standard and rotary porting systems for IC engine

    Energy Technology Data Exchange (ETDEWEB)

    Palmisano, R.; Ng, H.D. [Concordia Univ., Montreal, PQ (Canada). Dept. of Mechanical and Industrial Engineering

    2009-07-01

    A method of improving the efficiency of an internal combustion engine was presented. The proposed design used a new sealing technology to optimize a rotary valve design. The design was compared with standard poppet porting system using a computer aided engineering (CAE) method. A double port cylinder configuration was used in order to allow continuous flow into the chamber and minimize the exposed surface area in the combustion chamber. The design also minimized distortion on the component when exposed to high condensation pressures. A transfer case was used to allow for easy adaptation of the configuration to a multi-cylinder engine. A mechanism dynamics extension (MDO) program was used to conduct dynamic analyses on the rotary and standard valve porting systems. The study showed that the poppet system required 62 times more torque than the new rotary valve design. It was concluded that further research is needed to examine the flow properties of both designs. 2 refs., 6 figs.

  11. Design of data transportation based on dual-port RAM in IMS system

    International Nuclear Information System (INIS)

    Zhang Guohui; Li Yongping

    2010-01-01

    Ion mobility spectroscopy (IMS) is a rugged, portable, sensitive, low cost, field instrumental technique capable of trace organic detection and monitoring for environmental pollutants, pesticides, explosives, narcotics, and other analytes, hence it is of great significance to social security and stability. High rate data transmission mechanism between DSP processor and ARM core is required in the electronic system of IMS. After careful comparison of UART and dual port RAM, a new design based on dual port RAM that can be applied to other similar systems. (authors)

  12. From conservation laws to port-Hamiltonian representations of distributed-parameter systems

    NARCIS (Netherlands)

    Maschke, B.M.; van der Schaft, Arjan; Piztek, P.

    Abstract: In this paper it is shown how the port-Hamiltonian formulation of distributed-parameter systems is closely related to the general thermodynamic framework of systems of conservation laws and closure equations. The situation turns out to be similar to the lumped-parameter case where the

  13. Towards Ocean Grazer's Modular Power Take-Off System Modeling : A Port-Hamiltonian Approach

    NARCIS (Netherlands)

    Barradas-Berglind, J. J.; Muñoz Arias, M.; Wei, Y.; Prins, W.A.; Vakis, A.I.; Jayawardhana, B.; Dochain, Denis; Henrion, Didier; Peaucelle, Dimitri

    This paper presents a modular modeling framework for the Ocean Grazer's Power Take-Off (PTO) system, which operates as an array of point-absorber type devices connected to a hydraulic system. The modeling is based on the port-Hamiltonian (PH) framework that enables energy-based analysis and control

  14. Reliability assessment of Port Harcourt 33/11kv Distribution System ...

    African Journals Online (AJOL)

    This makes reliability studies an important task besides all the other analyses required for assessing the system performance. The paper presents an analytical approach in the reliability assessment of the Port Harcourt 33/11kV power distribution system. The assessment was performed with the 2009 power outage data ...

  15. A port-Hamiltonian approach to image-based visual servo control for dynamic systems

    NARCIS (Netherlands)

    Mahony, R.; Stramigioli, Stefano

    2012-01-01

    This paper introduces a port-Hamiltonian framework for the design of image-based visual servo control for dynamic mechanical systems. The approach taken introduces the concept of an image effort and provides an interpretation of energy exchange between the dynamics of the physical system and virtual

  16. Sensitivity of radiation monitoring systems in Manila Ports in detecting contamination in foodstuff shipments

    International Nuclear Information System (INIS)

    Romallosa, Kristine Marie D.; Caseria, Estrella S.; Piquero, Ronald E.; Agustin, Jan Aldrich A.

    2011-01-01

    During the Fukushima Nuclear Power Plant accident in Japan, one of the Philippines' measures to protect the public from radiological hazards of the accident is by monitoring agricultural and food imports for radioactive contamination. In this study, the sensitivity of the mobile Radiation Monitoring System (RM) in Manila Ports in detecting contamination in incoming foodstuff shipments was determined. Large volume synthetic 137 Cs reference sources were used to determine the minimum detectable concentration (MDC) of the RMS. The reference sources have radioactivity concentrations that are comparable to the PNRI guidance level of 1000 Bg/kg for 137 Cs that is destined for general consumption. Results of the MDC measurements show that the RMS units are sensitive enough to detect radioactivity levels that are within the guidance levels provided that a) the minimum package lot is approximately 200 kg, b) the package is positioned at the detector side, and c) the alarm setting of RMS is as calibrated. It was therefore established that the RMS can be used to initially screen incoming foodstuff shipments of possible contamination and thereby help minimize potential radiation exposures to the public. (author)

  17. Universal properties of two-port scattering, impedance, and admittance matrices of wave-chaotic systems

    International Nuclear Information System (INIS)

    Hemmady, Sameer; Zheng, Xing; Hart, James; Antonsen, Thomas M. Jr.; Ott, Edward; Anlage, Steven M.

    2006-01-01

    Statistical fluctuations in the eigenvalues of the scattering, impedance, and admittance matrices of two-port wave-chaotic systems are studied experimentally using a chaotic microwave cavity. These fluctuations are universal in that their properties are dependent only upon the degree of loss in the cavity. We remove the direct processes introduced by the nonideally coupled driving ports through a matrix normalization process that involves the radiation-impedance matrix of the two driving ports. We find good agreement between the experimentally obtained marginal probability density functions (PDFs) of the eigenvalues of the normalized impedance, admittance, and scattering matrix and those from random matrix theory (RMT). We also experimentally study the evolution of the joint PDF of the eigenphases of the normalized scattering matrix as a function of loss. Experimental agreement with the theory by Brouwer and Beenakker for the joint PDF of the magnitude of the eigenvalues of the normalized scattering matrix is also shown

  18. Main maintenance operations for Test Blanket Systems in ITER TBM port cells

    Energy Technology Data Exchange (ETDEWEB)

    Pascal, R., E-mail: romain.pascal@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Cortes, P.; Friconneau, J.-P.; Giancarli, L.M.; Gotewal, K.K.; Iseli, M.; Kim, B.Y.; Levesy, B.; Martins, J.-P.; Merola, M. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Nevière, J.-C. [Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Patisson, L. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Siarras, A. [Sogetti, Parc de la Duranne, 13857 Aix-en-Provence (France); Tesini, A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2013-10-15

    Highlights: • The Test Blanket System components layout in Port Cell room is described. • The maintenance of the two Test Blanket Systems in ITER port cell is addressed. • The overall replacement/maintenance strategy is defined. • The main maintenance tasks of the systems are discussed. • The maintenance strategy and required tools are presented. -- Abstract: Each Test Blanket System in ITER is formed by an in-vessel component, the Test Blanket Module, and several associated ancillary systems (coolant and Tritium systems, instrumentation and control systems). The paper describes the overall replacement/maintenance strategy and the main maintenance tasks that have to be considered in the design of the systems. It shows that there are no critical issues.

  19. Solar concentrator with integrated tracking and light delivery system with collimation

    Science.gov (United States)

    Maxey, Lonnie Curt

    2015-06-09

    A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector directs the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and distributes light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting, uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.

  20. Solar concentrator with integrated tracking and light delivery system with summation

    Science.gov (United States)

    Maxey, Lonnie Curt

    2015-05-05

    A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector redirects the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and provides light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting that uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.

  1. Database specification for the Worldwide Port System (WPS) Regional Integrated Cargo Database (ICDB)

    Energy Technology Data Exchange (ETDEWEB)

    Faby, E.Z.; Fluker, J.; Hancock, B.R.; Grubb, J.W.; Russell, D.L. [Univ. of Tennessee, Knoxville, TN (United States); Loftis, J.P.; Shipe, P.C.; Truett, L.F. [Oak Ridge National Lab., TN (United States)

    1994-03-01

    This Database Specification for the Worldwide Port System (WPS) Regional Integrated Cargo Database (ICDB) describes the database organization and storage allocation, provides the detailed data model of the logical and physical designs, and provides information for the construction of parts of the database such as tables, data elements, and associated dictionaries and diagrams.

  2. Study of Large Data Resources for Multilingual Training and System Porting (Pub Version, Open Access)

    Science.gov (United States)

    2016-05-03

    extraction trained on a large database corpus – English Fisher. Although the performance of ported monolingual system would be worse in comparison...Language TE LI HA LA ZU LLP hours 8.6 9.6 7.9 8.1 8.4 LM sentences 11935 10743 9861 11577 10644 LM words 68175 83157 93131 93328 60832 dictionary 14505

  3. Ascaris and Escherichia coli Inactivation in an Ecological Sanitation System in Port-au-Prince, Haiti.

    Directory of Open Access Journals (Sweden)

    David Berendes

    Full Text Available The goal of this study was to evaluate the microbial die-off in a latrine waste composting system in Port-au-Prince, Haiti. Temperature data and samples were collected from compost aged 0-12+ months. Samples collected from compost bin centers and corners at two depths were assessed for moisture content, E. coli concentration, and Ascaris spp. viability. Center temperatures in compost bins were all above 58 °C, while corner temperatures were 10 - 20 °C lower. Moisture content was 67 ± 10% in all except the oldest compost. A 4-log reduction in E. coli was observed over the first sixteen weeks of composting at both locations and depths, after which E. coli was undetectable (LOD: 142 MPN g(-1 dry weight. In new compost, 10.4% and 8.3% of Ascaris eggs were viable and fully embryonated, respectively. Percent viability dropped to zero in samples older than six weeks. These findings indicate that the Haitian EcoSan composting process was effective in inactivating E. coli and Ascaris spp. in latrine waste within sixteen weeks. This study is one of the first to document efficacy of an ecological sanitation system under field conditions and provides insight into composting methods and monitoring for other international settings.

  4. Environmental Factors' Consideration at Industrial Transportation Organization in the «Seaport - Dry port» System

    Science.gov (United States)

    Muravev, Dmitri; Rakhmangulov, Aleksandr

    2016-11-01

    Currently, container shipping development is directly associated with an increase of warehouse areas for containers' storage. One of the most successful types of container terminal is an intermodal terminal called a dry port. Main pollution sources during the organization of intermodal transport are considered. A system of dry port parameters, which are recommended for the evaluation of different scenarios for a seaport infrastructure development at the stage of its strategic planning, is proposed in this paper. The authors have developed a method for determining the optimal values of the main dry port parameters by simulation modeling in the programming software Any- Logic. Dependencies thatwere obtained as a result of modeling experiments prove the adequacy of main selected dry port parameters for the effective scenarios' evaluation of throughput and handling capacity at existing seaports at the stage of strategic planning and a rational dry port location, allowed ensuring the improvement of the ecological situation in a port city.

  5. Concept design of CFETR superconducting magnet system based on different maintenance ports

    International Nuclear Information System (INIS)

    Zheng, Jinxing; Liu, Xufeng; Song, Yuntao; Wan, Yuanxi; Li, Jiangang; Wu, Sontao; Wan, Baonian; Ye, Minyou; Wei, Jianghua; Xu, Weiwei; Liu, Sumei; Weng, Peide; Lu, Kun; Luo, Zhengping

    2013-01-01

    Highlights: • This article discussed the concept design of the magnet system of CFETR based on different maintenance port cases. • The major and minor radius of plasma is 5.7 m and 1.6 m, and the central magnetic field was designed as 4.5/5.0 T. • The different maintenance ports design have little impact on the design of TF and CS coils’ design, but have certain impact on the PF coils’ design. -- Abstract: CFETR which stands for “China Fusion Engineering Test Reactor” is a new tokamak device. Its magnet system includes the Toroidal Field (TF) winding, Center solenoid winding (CS) and Poloidal Field (PF) winding. The main goal of the project is to build a fusion engineering Tokamak reactor with its fusion power is 50–200 MW and should be self-sufficiency by blanket. In order to ensure the maintenance ports design and maintenance method, this article discussed the concept design of the magnet system based on different maintenance port cases. The paper detailed studied the magnet system of CFETR including the electromagnetic analysis and parameters for TF (CS)PF. Besides, the volt-seconds of ohmic field are presented as detailed as possible in this paper. In addition, the calculations and optimizations of equilibrium field which should guarantee the plasma discharge of single null shape is carried out. The design work reported here illustrates that the present maintenance ports will not have a great impact on the design of the magnet system. The concept design of the magnet system can meet the requirement of the physical target

  6. [A novel serial port auto trigger system for MOSFET dose acquisition].

    Science.gov (United States)

    Luo, Guangwen; Qi, Zhenyu

    2013-01-01

    To synchronize the radiation of microSelectron-HDR (Nucletron afterloading machine) and measurement of MOSFET dose system, a trigger system based on interface circuit was designed and corresponding monitor and trigger program were developed on Qt platform. This interface and control system was tested and showed stable operate and reliable work. This adopted serial port detect technique may expand to trigger application of other medical devices.

  7. System for Determining Dynamic Under Keel Clearance of Vessels Entering the Port of Swinoujscie (DRWPS

    Directory of Open Access Journals (Sweden)

    Lucjan Gucma

    2017-09-01

    Full Text Available The article presents a system for determining dynamic under keel clearance. In order to build a DRWPS system, a mixed model was created based on the analysis of math models. The system includes advisory software for defining the conditions for the entering of large LNG vessels in the context of under keel clearance and software was built to support the decision-making of operators who are responsible for introducing these vessels to the Port of Swinoujscie.

  8. Integrated model of port oil piping transportation system safety including operating environment threats

    Directory of Open Access Journals (Sweden)

    Kołowrocki Krzysztof

    2017-06-01

    Full Text Available The paper presents an integrated general model of complex technical system, linking its multistate safety model and the model of its operation process including operating environment threats and considering variable at different operation states its safety structures and its components safety parameters. Under the assumption that the system has exponential safety function, the safety characteristics of the port oil piping transportation system are determined.

  9. A Three-Port Topology Comparison for a Low Power Stand-Alone Photovoltaic System

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using c...... component stress factor (CSF) is performed, which gives a quantitative measure of the performance of the converter. The candidate topologies are compared to each other according to a defined LED lighting strategy and a solar irradiation profile.......Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using...

  10. System/subsystem specifications for the Worldwide Port System (WPS) Regional Integrated Cargo Database (ICDB)

    Energy Technology Data Exchange (ETDEWEB)

    Rollow, J.P.; Shipe, P.C.; Truett, L.F. [Oak Ridge National Lab., TN (United States); Faby, E.Z.; Fluker, J.; Grubb, J.; Hancock, B.R. [Univ. of Tennessee, Knoxville, TN (United States); Ferguson, R.A. [Science Applications International Corp., Oak Ridge, TN (United States)

    1995-11-20

    A system is being developed by the Military Traffic Management Command (MTMC) to provide data integration and worldwide management and tracking of surface cargo movements. The Integrated Cargo Database (ICDB) will be a data repository for the WPS terminal-level system, will be a primary source of queries and cargo traffic reports, will receive data from and provide data to other MTMC and non-MTMC systems, will provide capabilities for processing Advance Transportation Control and Movement Documents (ATCMDs), and will process and distribute manifests. This System/Subsystem Specifications for the Worldwide Port System Regional ICDB documents the system/subsystem functions, provides details of the system/subsystem analysis in order to provide a communication link between developers and operational personnel, and identifies interfaces with other systems and subsystems. It must be noted that this report is being produced near the end of the initial development phase of ICDB, while formal software testing is being done. Following the initial implementation of the ICDB system, maintenance contractors will be in charge of making changes and enhancing software modules. Formal testing and user reviews may indicate the need for additional software units or changes to existing ones. This report describes the software units that are components of this ICDB system as of August 1995.

  11. Final design of the generic equatorial port plug structure for ITER diagnostic systems

    International Nuclear Information System (INIS)

    Udintsev, V.S.; Maquet, P.; Alexandrov, E.; Casal, N.; Cuenca, D.; Drevon, J.-M.; Feder, R.; Friconneau, J.P.; Giacomin, T.; Guirao, J.; Iglesias, S.; Josseaume, F.; Levesy, B.; Loesser, D.; Ordieres, J.; Quinn, E.; Pak, S.; Penot, C.; Pitcher, C.S.; Portalès, M.

    2015-01-01

    The Diagnostic Generic Equatorial Port Plug (GEPP) is designed to be common to all equatorial port-based diagnostic systems. It is designed to survive throughout the lifetime of ITER for 20 years, 30,000 discharges, and 3000 disruptions. The EPP structure dimensions (without Diagnostic First Walls and Diagnostic Shield Modules) are L2.9 × W1.9 × H2.4 m"3. The length of the fully integrated EPP is 3174 mm. The weight of the EPP structure is about 15 t, whereas the total weight of the integrated EPP may be up to 45 t. The EPP structure provides a flexible platform for a variety of diagnostics. The Diagnostic Shield Module assemblies, or drawers, allow a modular approach with respect to diagnostic integration and maintenance. In the nuclear phase of ITER operations, they will be remotely inserted into the EPP structure in the Hot Cell Facility. The port plug structure must also contribute to the nuclear shielding, or plugging, of the port and further contain circulated water to allow cooling during operation and heating during bake-out. The Final Design of the GEPP has been successfully passed in late 2013 and is now heading toward manufacturing. The final design of the GEPP includes interfaces, manufacturing, R&D, operation and maintenance, load cases and analysis of failure modes.

  12. Progress in the integration of Test Blanket Systems in ITER equatorial port cells and in the interfaces definition

    Energy Technology Data Exchange (ETDEWEB)

    Pascal, R., E-mail: romain.pascal@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Beloglazov, S.; Bonagiri, S. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Commin, L. [CEA, IRFM, Cadarache (France); Cortes, P.; Giancarli, L.M.; Gliss, C.; Iseli, M.; Lanza, R.; Levesy, B.; Martins, J.-P. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Neviere, J.-C. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Patisson, L.; Plutino, D.; Shu, W. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Swami, H.L. [Institute for Plasma Research, Bhat, Gandhinagar 382428 (India)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer The design integration of two test blanket systems in ITER port cell is addressed. Black-Right-Pointing-Pointer Definition of interfaces of TBSs with building and other ITER systems is done. Black-Right-Pointing-Pointer Designs of pipe forest, bioshield plug and ancillary equipment unit are described. Black-Right-Pointing-Pointer The maintenance of the two test blanket systems in ITER port cell is considered. Black-Right-Pointing-Pointer The management of the heat and tritium releases in the TBM port cell is described. - Abstract: In the framework of the TBM Program, three ITER vacuum vessel equatorial ports (no. 16, no. 18 and no. 02) have been allocated for the testing of up to six mock-ups of six different DEMO tritium breeding blankets. Each one is called a Test Blanket System (TBS). A TBS consists mainly of the Test Blanket Module (TBM), the in-vessel component facing the plasma, and several ancillary systems, in particular the cooling system and the tritium extraction system. Each port accommodates two TBMs and therefore the two TBSs have to share the corresponding port cell. This paper deals with the design integration aspects of the two TBSs in each port cell performed at ITER Organization (IO) with the corresponding definition of interfaces with other ITER systems. The performed activities have raised several issues that are discussed in the paper and for which design solutions are proposed.

  13. Stabilization of (state, input)-disturbed CSTRs through the port-Hamiltonian systems approach

    OpenAIRE

    Lu, Yafei; Fang, Zhou; Gao, Chuanhou

    2017-01-01

    It is a universal phenomenon that the state and input of the continuous stirred tank reactor (CSTR) systems are both disturbed. This paper proposes a (state, input)-disturbed port-Hamiltonian framework that can be used to model and further designs a stochastic passivity based controller to asymptotically stabilize in probability the (state, input)-disturbed CSTR (sidCSTR) systems. The opposite entropy function and the availability function are selected as the Hamiltonian for the model and con...

  14. Effectiveness of a Barge-Based Ballast Water Treatment System for Multi-Terminal Ports

    Directory of Open Access Journals (Sweden)

    Lovro Maglić

    2015-10-01

    Full Text Available The paper presents outcomes of the discrete event simulation of the ballast water management in a multi-terminal port. The simulation includes ship’s manoeuvring, cargo and ballast operations and a barge-based ballast water treatment system operating within all terminal areas. The barge-based ballast water treatment system is used by ships unable to use their own equipment, not equipped with an appropriate ballast treatment system or non-compliant with the Ballast Water Management (BWM Convention 2004 for whatever reason. The main goal is to estimate the productivity and cost effectiveness of such systems as an option to support ships not able to comply with the BWM Convention, once it enters into force. The model was built and tested in Arena simulation software. Process parameters are based on real traffic data for the port of Rijeka. The results indicate that barge-based ballast treatment facility will be heavily underutilized, and that such systems are cost-effective only in ports where large volumes of ballast water need to be delivered to shore treatment systems.

  15. International Standardization in the Design of "Shore to Ship" - Power Supply Systems of Ships in Port

    Science.gov (United States)

    Tarnapowicz, Dariusz; German-Galkin, Sergiej

    2018-03-01

    The decisive source of air pollution emissions in ports is the berthed ships. This is primarily caused by the work of ship's autonomous generator sets. One way of reducing the air pollution emissions in ports is the supply of ships from electricity inland system. The main problem connected with the power connection of ships to the inland network is caused by different values of levels and frequencies of voltages in these networks (in various countries) in relation to different values of levels and frequencies of voltages present in the ship's network. It is also important that the source power can range from a few hundred kW up to several MW. In order to realize a universal „Shore to Ship" system that allows the connection of ships to the electricity inland network, the international standardization is necessary. This article presents the current recommendations, standards and regulations for the design of „Shore to Ship" systems.

  16. Simulation-Based Planning and Control of Transport Flows in Port Logistic Systems

    Directory of Open Access Journals (Sweden)

    Antonio Diogo Passos Lima

    2015-01-01

    Full Text Available In highly dynamic and uncertain transport conditions, transport transit time has to be continuously monitored so that the service level is ensured at a proper cost. The aim of this research is to propose and to test a procedure which allows an agile planning and control of transport flows in port logistic systems. The procedure couples an agent-based simulation and a queueing theory model. In this paper, the transport scheduling performed by an agent at the intermodal terminal was taken into consideration. The decision-making agent takes into account data which is acquired in remote points of the system. The obtained results indicate the relevance of continuously considering, for the transport planning and control, the expected transit time and further waiting times along port logistic systems.

  17. Ports Initiative

    Science.gov (United States)

    EPA's Ports Initiative works in collaboration with the port industry, communities, and government to improve environmental performance and increase economic prosperity. This effort helps people near ports breath cleaner air and live better lives.

  18. Reliability evaluation of a port oil transportation system in variable operation conditions

    International Nuclear Information System (INIS)

    Soszynska, Joanna

    2006-01-01

    The semi-Markov model of the system operation processes is proposed and its selected parameters are determined. The series 'm out of k n ' multi-state system is considered and its reliability and risk characteristics are found. Next, the joint model of the system operation process and the system multi-state reliability and risk is constructed. Moreover, reliability and risk evaluation of the multi-state series 'm out of k n ' system in its operation process is applied to the port oil transportation system

  19. Reliability evaluation of a port oil transportation system in variable operation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Soszynska, Joanna [Department of Mathematics, Gdynia Maritime University, ul. Morska 83, 81-225 Gdynia (Poland)]. E-mail: joannas@am.gdynia.pl

    2006-04-15

    The semi-Markov model of the system operation processes is proposed and its selected parameters are determined. The series 'm out of k {sub n}' multi-state system is considered and its reliability and risk characteristics are found. Next, the joint model of the system operation process and the system multi-state reliability and risk is constructed. Moreover, reliability and risk evaluation of the multi-state series 'm out of k {sub n}' system in its operation process is applied to the port oil transportation system.

  20. Higher complication risk of totally implantable venous access port systems in patients with advanced cancer - a single institution retrospective analysis.

    Science.gov (United States)

    Chang, Yi-Fang; Lo, An-Chi; Tsai, Chung-Hsin; Lee, Pei-Yi; Sun, Shen; Chang, Te-Hsin; Chen, Chien-Chuan; Chang, Yuan-Shin; Chen, Jen-Ruei

    2013-02-01

    Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer. The aim of this study was to assess the risk of port system failure in patients with advanced cancer. We conducted a retrospective cohort study in a comprehensive cancer centre. A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion. Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion. Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.

  1. Treatment of PPROM with anhydramnion in humans: first experience with different amniotic fluid substitutes for continuous amnioinfusion through a subcutaneously implanted port system.

    Science.gov (United States)

    Tchirikov, Michael; Bapayeva, Gauri; Zhumadilov, Zhaxybay Sh; Dridi, Yasmina; Harnisch, Ralf; Herrmann, Angelika

    2013-11-01

    This study aims to treat patients with preterm premature rupture of the membranes (PPROM) and anhydramnion using continuous amnioinfusion through a subcutaneously implanted port system. An amniotic fluid replacement port system was implanted in seven patients with PPROM and anhydramnion starting at the 20th week of gestation (range, 14-26 weeks) for long-term amnioinfusion. Saline solutions (2 L/day; Jonosteril(®), Sterofundin(®), isotonic NaCl 0.9% solution, lactated Ringer's solution) and a hypotonic aqueous composition with reduced chloride content similar to the electrolyte concentration of human amniotic fluid were used for the continuous amnioinfusion. The mean duration of the PPROM delivery interval continued for 49 days (range, 9-69 days), with 3 weeks of amnioinfusion via the port system (range, 4-49). The newborns showed no signs of lung hypoplasia. Long-term lavage of the amniotic cavity via a subcutaneously implanted port system in patients with PPROM and anhydramnion may help prolong the pregnancy and avoid fetal lung hypoplasia. A hypotonic aqueous composition with reduced chloride content similar to human amniotic fluid can be safely used for amnioinfusion. Prospective randomized studies are ongoing.

  2. A general method for measuring the scattering matrices of N-port systems

    International Nuclear Information System (INIS)

    Bizarro, J.P.; Pain, M.

    1989-01-01

    Arising from the need to test the multijunctions that will build up the JET (Joint European Torus) lower hybrid antenna, a general model to measure scattering matrices of microwave devices was developed. The model allows for devices with any number of ports and for the use of adaptors between the measuring system and the device under test. Its accuracy can be as good as 1% for waveguide components. (author)

  3. High Efficiency Non-isolated Three Port DC-DC Converter for PV-Battery Systems

    DEFF Research Database (Denmark)

    Tomas Manez, Kevin; Anthon, Alexander; Zhang, Zhe

    2016-01-01

    This paper presents a nonisolated Three Port Converter (TPC) with a unidirectional port for photovoltaic (PV) panels and a bidirectional port for energy storage. With the proposed topology single power conversion is performed between each port, so high efficiencies are obtained. A theoretical...

  4. Weak form of Stokes-Dirac structures and geometric discretization of port-Hamiltonian systems

    Science.gov (United States)

    Kotyczka, Paul; Maschke, Bernhard; Lefèvre, Laurent

    2018-05-01

    We present the mixed Galerkin discretization of distributed parameter port-Hamiltonian systems. On the prototypical example of hyperbolic systems of two conservation laws in arbitrary spatial dimension, we derive the main contributions: (i) A weak formulation of the underlying geometric (Stokes-Dirac) structure with a segmented boundary according to the causality of the boundary ports. (ii) The geometric approximation of the Stokes-Dirac structure by a finite-dimensional Dirac structure is realized using a mixed Galerkin approach and power-preserving linear maps, which define minimal discrete power variables. (iii) With a consistent approximation of the Hamiltonian, we obtain finite-dimensional port-Hamiltonian state space models. By the degrees of freedom in the power-preserving maps, the resulting family of structure-preserving schemes allows for trade-offs between centered approximations and upwinding. We illustrate the method on the example of Whitney finite elements on a 2D simplicial triangulation and compare the eigenvalue approximation in 1D with a related approach.

  5. OPERATING SYSTEM FOR WIRELESS SENSOR NETWORKS AND AN EXPERIMENT OF PORTING CONTIKIOS TO MSP430 MICROCONTROLLER

    Directory of Open Access Journals (Sweden)

    Thang Vu Chien

    2012-07-01

    Full Text Available Wireless Sensor Networks (WSNs consist of a large number of sensor nodes, and are used for various applications such as building monitoring, environment control, wild-life habitat monitoring, forest fire detection, industry automation, military, security, and health-care. Each sensor node needs an operating system (OS that can control the hardware, provide hardware abstraction to application software, and fill in the gap between applications and the underlying hardware. In this paper, researchers present OS for WSNs and an experiment of porting contikiOS to MSP430 microcontroller which is very popular in many hardware platforms for WSNs. Researchers begin by presenting the major issues for the design of OS for WSNs. Then, researchers examine some popular operating systems for WSNs including TinyOS, ContikiOS, and LiteOS. Finally, researchers present an experiment of porting ContikiOS to MSP430 microcontroller. Wireless Sensor Networks (WSNs terdiri dari sejumlah besar sensor nodes, dan digunakan untuk berbagai aplikasi seperti pemantauan gedung, pengendalian lingkungan, pemantauan kehidupan habitat liar, deteksi kebakaran hutan, otomatisasi industri, militer, keamanan, dan kesehatan. Setiap sensor nodememerlukan sistem operasi (SO yang dapat mengontrol hardware, menyediakan abstraksi hardware untuk aplikasi perangkat lunak, dan mengisi kesenjangan antara aplikasi dan hardware. Dalam penelitian ini, peneliti menyajikan SO untuk WSNs dan percobaan dari port contikiOS untuk MSP430 mikrokontroler yang sangat populer di platformhardware untuk WSNs. Peneliti memulai dengan menghadirkan isu utama yaitu desain SO untuk WSNs. Lalu, penelitimemeriksa beberapa sistem operasi populer untuk WSNs, termasuk TinyOS, ContikiOS, dan LiteOS. Akhirnya penelitimenyajikan sebuah percobaan dari port ContikiOS untuk MSP430 mikrokontroler.

  6. New Futures for Older Ports: Synergistic Development in a Global Urban System

    Directory of Open Access Journals (Sweden)

    Joe Ravetz

    2013-11-01

    Full Text Available Port cities are on the front-line of a changing global urban system. There are problems from restructuring of trade, logistics and ship-building, creating economic dependency, social exclusion and cultural destruction. Meanwhile, there exists new opportunities in heritage tourism, cultural industries and ecological restoration, but these opportunities often have negative impacts. This paper addresses the question of how port cities can steer from negative to positive development paths and outcomes. It sets out a way of working with inter-connected economic, social, political and technological factors—a ‘synergistic’ approach to mapping of problems and design of policy responses. Looking at three contrasting examples of port cities—Liverpool, Dubai and Mauritius—we can compare the inter-connected dynamics of growth and decline. Then we can understand the inter-connected factors of successful regeneration and sustainable prosperity, not as linear ‘policy fixes’, but more like synergistic processes of learning, innovation and capacity building. These call for new models for creative innovation in social and community enterprise: cultural heritage both old and new; new social finance and investment; socio-ecological restoration with participative governance, etc. Such pathways and opportunities are now emerging in many different locations; this paper provides methods and tools to understand them and promote them.

  7. The SimPort-based simulators and distributed control systems development, upgrade and testing

    International Nuclear Information System (INIS)

    Danilov, Victor A.; Yanushevich, Dmitry I.; Zenkov, Andrey D.

    2004-01-01

    This paper describes the SimPort computer technology application experience related with power plant simulators and Distributed Control System (DCS) emulators development. The paper presents basic characteristics of the SimPort as a Windows NT-based implementation variety of the developed in RRC 'Kurchatov Institute' math modeling and simulator creation AIS technology. The new approaches and benefits of using simulation for DCS development and, especially upgrade, testing and on plant tuning are presented in the paper briefly. The DCS-inclusive power plant SimPort-based simulators are also considered. The DCS emulation principal problems, solutions and the experience-based DCS emulators development methodology are presented also. The presented technology quality and efficiency as well as presented DCS emulation problem solutions were verified by the smallest power plant full scope computer simulators development man-hours (at least twice lower in comparison with the similar simulators) in combination with the simulators correspondence to the standard and the best quality of nuclear power plant simulators. (Author)

  8. Long-term amnioinfusion through a subcutaneously implanted amniotic fluid replacement port system for treatment of PPROM in humans.

    Science.gov (United States)

    Tchirikov, Michael; Steetskamp, Joscha; Hohmann, Manfred; Koelbl, Heinz

    2010-09-01

    To introduce a novel method for the treatment of PPROM (preterm premature rupture of membranes) using continuous amnioinfusion via a subcutaneously implanted port system. After development and testing since 2001 in a fetal sheep model, the port system has been successfully implanted in two humans with PPROM. In the first case, the subcutaneous port system was implanted during the 23rd week of gestation in a 39-year-old 5th-gravida with PPROM since the 18th week of gestation; in the second case, the port system was implanted during the 24th week of gestation in a 27-year-old 3rd gravida with PPROM since the 21st week of gestation. After port implantation, 100ml/h saline solution was infused intermittently into the amniotic cavity. The whole course of treatment was supported by tocolysis. In the cases presented, gestation was terminated by cesarean section, in one case in the 29th week of gestation, and in the other case in the 30th week. The newborns showed no signs of lung hypoplasia and were successfully extubated on the 1st or 2nd day after delivery. Six months later the children did not exhibit any deviation from the normal development. Long-term amnioinfusion via a subcutaneously implanted port system could be used in humans with PPROM for prolongation of pregnancy and to avoid lung hypoplasia. Prospective randomized studies are ongoing. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  9. A data-management system using sensor technology and wireless devices for port security

    Science.gov (United States)

    Saldaña, Manuel; Rivera, Javier; Oyola, Jose; Manian, Vidya

    2014-05-01

    Sensor technologies such as infrared sensors and hyperspectral imaging, video camera surveillance are proven to be viable in port security. Drawing from sources such as infrared sensor data, digital camera images and processed hyperspectral images, this article explores the implementation of a real-time data delivery system. In an effort to improve the manner in which anomaly detection data is delivered to interested parties in port security, this system explores how a client-server architecture can provide protected access to data, reports, and device status. Sensor data and hyperspectral image data will be kept in a monitored directory, where the system will link it to existing users in the database. Since this system will render processed hyperspectral images that are dynamically added to the server - which often occupy a large amount of space - the resolution of these images is trimmed down to around 1024×768 pixels. Changes that occur in any image or data modification that originates from any sensor will trigger a message to all users that have a relation with the aforementioned. These messages will be sent to the corresponding users through automatic email generation and through a push notification using Google Cloud Messaging for Android. Moreover, this paper presents the complete architecture for data reception from the sensors, processing, storage and discusses how users of this system such as port security personnel can use benefit from the use of this service to receive secure real-time notifications if their designated sensors have detected anomalies and/or have remote access to results from processed hyperspectral imagery relevant to their assigned posts.

  10. A novel robotic system for single-port urologic surgery: first clinical investigation.

    Science.gov (United States)

    Kaouk, Jihad H; Haber, Georges-Pascal; Autorino, Riccardo; Crouzet, Sebastien; Ouzzane, Adil; Flamand, Vincent; Villers, Arnauld

    2014-12-01

    The idea of performing a laparoscopic procedure through a single abdominal incision was conceived with the aim of expediting postoperative recovery. To determine the clinical feasibility and safety of single-port urologic procedures by using a novel robotic surgical system. This was a prospective institutional review board-approved, Innovation, Development, Exploration, Assessment, Long-term Study (IDEAL) phase 1 study. After enrollment, patients underwent a major urologic robotic single-port procedure over a 3-wk period in July 2010. The patients were followed for 3 yr postoperatively. Different types of urologic surgeries were performed using the da Vinci SP Surgical System. This system is intended to provide the same core clinical capabilities as the existing multiport da Vinci system, except that three articulating endoscopic instruments and an articulating endoscopic camera are inserted into the patient through a single robotic port. The main outcomes were the technical feasibility of the procedures (as measured by the rate of conversions) and the safety of the procedures (as measured by the incidence of perioperative complications). Secondary end points consisted of evaluating other key surgical perioperative outcomes as well as midterm functional and oncologic outcomes. A total of 19 patients were enrolled in the study. Eleven of them underwent radical prostatectomy; eight subjects underwent nephrectomy procedures (partial nephrectomy, four; radical nephrectomy, two; and simple nephrectomy, two). There were no conversions to alternative surgical approaches. Overall, two major (Clavien grade 3b) postoperative complications were observed in the radical prostatectomy group and none in the nephrectomy group. At 1-yr follow-up, one radical prostatectomy patient experienced biochemical recurrence, which was successfully treated with salvage radiation therapy. The median warm ischemia time for three of the partial nephrectomies was 38 min. At 3-yr follow-up all

  11. High Efficiency Non-isolated Three Port DC-DC Converter for PV-Battery Systems

    OpenAIRE

    Tomas Manez, Kevin; Anthon, Alexander; Zhang, Zhe; Ouyang, Ziwei; Franke, Toke

    2016-01-01

    This paper presents a nonisolated Three Port Converter (TPC) with a unidirectional port for photovoltaic (PV) panels and a bidirectional port for energy storage. With the proposed topology single power conversion is performed between each port, so high efficiencies are obtained. A theoretical analysis is carried out to analyze all operating modes and design considerations with the main equations are given. A 4kW laboratory prototype is developed and tested under all operatingconditions. Resul...

  12. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  13. Principal Ports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Principal Ports are defined by port limits or US Army Corps of Engineers (USACE) projects, these exclude non-USACE projects not authorized for publication. The...

  14. A system dynamics approach to intermodalism at the Port of Lewiston

    Energy Technology Data Exchange (ETDEWEB)

    Sebo, D.

    1996-08-01

    Intermodalism refers to interconnections among modes of transportation, e.g., road, rail, water, and air. Effective intermodal planning must cross boundaries between the public and private sectors as well as transportation modes. The development of an effective and efficient intermodal transportation system requires the identification of barriers to intermodal transportation and the investigation of the impact of proposed changes in infrastructure development, policies, regulations, and planning. A systems approach is necessary to adequately represent the interaction between the sometimes incompatible concerns of all modes and stakeholders. A systems dynamics model of intermodalism at the Port of Lewiston has been developed to highlight leverage points, hidden assumptions, second order effects resulting from feedback loops and system drivers. The purpose of this document is to present the results of the system dynamics model work.

  15. Automatic Supervisory System Synthesis for Port Cranes Collision Prevention by Using Petri Net

    Directory of Open Access Journals (Sweden)

    Danko Kezić

    2006-05-01

    Full Text Available The article deals with the system of port cranes comprisingtwo independently controlled cranes which are simultaneouslyengaged in the transhipment of cargo between a vessel and arailway wagon assembly alongside. The crane operator's errorcan lead to tlie collision of cranes. Therefore, it is necessary toinstall the supervisor in an automatic control system with thefunctions of continuous supervision of the process of cranemovement, and blocking of commands that can lead to collision.The article shows the method of crane system modellingas a discrete event system by using PIT and P-timed Petri nets.There is a proposal of a formal mathematic method for calculationof the state supervisor by P-invariant method. The supervisorcalculated in this way is maximally permissive supervisor.The efficiency of the supervisor is verified by a computer simulation.

  16. A compact multiparameter acquisition system for radon concentration studies

    Science.gov (United States)

    Pugliese; Baiano; Boiano; D'Onofrio; Roca; Sabbarese; Vollaro

    2000-07-01

    A compact device suitable to acquire and display, at the same time, radon concentrations in a given atmosphere, and the environmental parameters characterising the atmosphere, is presented and described. It consists of two main blocks: (i) a detection section including a set of sensors for measuring pressure, humidity and temperature, and a set of silicon surface barrier detectors mounted in electrostatic cells collecting the ionised radon daughters; (ii) a single NIM module featuring an eight channel 12 bit ADC and the linear electronics to shape the signals from the silicon detectors. The system is controlled by a computer via a RS232 port. The software, implemented in Visual Basic, allows to display the energy distribution of the pulses coming from the alpha detectors and to initialise and control all phases of the acquisition. The results of preliminary tests show the high reliability of the system.

  17. A compact multiparameter acquisition system for radon concentration studies

    International Nuclear Information System (INIS)

    Pugliese, M.; Baiano, G.; Boiano, A.; D'Onofrio, A.; Roca, V.; Sabbarese, C.; Vollaro, P.

    2000-01-01

    A compact device suitable to acquire and display, at the same time, radon concentrations in a given atmosphere, and the environmental parameters characterising the atmosphere, is presented and described. It consists of two main blocks: (i) a detection section including a set of sensors for measuring pressure, humidity and temperature, and a set of silicon surface barrier detectors mounted in electrostatic cells collecting the ionised radon daughters; (ii) a single NIM module featuring an eight channel 12 bit ADC and the linear electronics to shape the signals from the silicon detectors. The system is controlled by a computer via a RS232 port. The software, implemented in Visual Basic, allows to display the energy distribution of the pulses coming from the alpha detectors and to initialise and control all phases of the acquisition. The results of preliminary tests show the high reliability of the system

  18. Study of ITER equatorial port plug handling system and vacuum sealing interface

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Jean-Pierre [Association Euratom CEA, CEA/DSM/IRFM, Cadarache, F-13108 Saint-Paul-lez-Durance (France)], E-mail: jean-pierre.martins@cea.fr; Doceul, Louis; Marol, Sebastien; Delchie, Elise [Association Euratom CEA, CEA/DSM/IRFM, Cadarache, F-13108 Saint-Paul-lez-Durance (France); Cordier, Jean-Jacques; Levesy, Bruno; Tesini, Alessandro [ITER International Organization, F-13108 Saint-Paul-lez-Durance cedex (France); Ciattaglia, Emanuela [EFDA CSU - Garching, Boltzmannstr. 2, D-85748 Garching (Germany); Tivey, Richard [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany); Gillier, Rene; Abbes, Christophe [GARLOCK - Sealing Technologies - 90, rue de la roche du Geai, F-42029 St-Etienne cedex 1 (France)

    2009-06-15

    In the field of the ITER port plug engineering and integration task, CEA has contributed to define proposals concerning the port plugs vacuum sealing interface with the vessel flange and the equatorial plug handling. The 2001 baseline vacuum flange sealing consisted of TIG welding of a 316L strip plate on to U shapes. This arrangement presented some issues like welding access, implementation of tools, lip consumption, complex local leak test, continuous leak checking. Therefore, an alternate sealing solution based on the use of metallic gaskets is proposed. The different technical aspects are discussed to explain how this design can simplify the maintenance and deal with safety and vacuum requirements. The design of the mechanical attachment and vacuum sealing of the plug has constantly evolved, but the associated remote handling equipment was not systematically reviewed. An update of the cask and maintenance procedure was studied in order to design it in accordance with the last generic plug flange design. This includes a concept of a gripping system that uses the plug flange bolting area and, to help the remote handling process, a cantilever assisting system is suggested to increase the reliability of the transfer operation between vacuum vessel and cask.

  19. Petri Net Approach of Collision Prevention Supervisor Design in Port Transport System

    Directory of Open Access Journals (Sweden)

    Danko Kezić

    2007-09-01

    Full Text Available Modern port terminals are equipped with various localtransport systems, which have the main task to transport cargobetween local storehouses and transport resources (ships,trains, trucks in the fastest and most efficient way, and at thelowest possible cost. These local transport systems consist offully automated transport units (AGV- automatic guided vehiclewhich are controlled by the computer system. The portcomputer system controls the fully automated transport units inthe way to avoid possible deadlocks and collisions betweenthem. However, beside the fully automated local transportunits, there are human operated transport units (fork-lifttrucks, cranes etc. which cross the path oftheAGVfrom timeto time. The collision of human operated transp011 unit andA GV is possible due to human inattention. To solve this problem,it is necesswy to design a supe1vismy control system thatcoordinates and controls both human driven transport unit andA G V In other words, the human-machine interactions need tobe supen·ised. The supen•ising system can be realized in the waythat the port terminal is divided into zones. Vehicle movementsare supen•ised by a video system which detects the moving ofparticular l'ehicles as a discrete event. Based on detected events,dangerous moving of certain vehicles is blocked by the supe1visi11gsystem. The paper considers the design of collision preventionsupen•isor by using discrete event dynamic themy. The portterminal is modeled by using ordi1za1y Petri nets. The design ofcollision prevention supe1visor is cmTied out by using the P-inl'ariantmethod. The verification of the supervisor is done bycomputer simulation.

  20. Three-Port dc-dc Conversion in Light-to-Light Systems

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen

    conversion efficiency under low irradiation conditions. This work is part of a Ph.D. research project to study the feasibility of implementing three-port converter (TPC) topologies in solar powered LED, light-to-light (LtL) systems. After the introduction in Chapter 1, an overview of the state-of-the art...... conventional light sources based on heated filaments (incandescent and halogen) and gas discharge (fluorescent, sodium, etc). The rapid development of this technology makes it possible to replace the conventional technologies towards high brightness LED lighting systems. The combination of these technologies......—solar cells, energy storage elements and LEDs—in a stand-alone solar powered LED system, can provide light where otherwise it would be cumbersome; in rural areas, where cabling can be challenging and expensive, and also in the urban environment, where the cost of digging and construction is very expensive...

  1. Dynamism Patterns of Western Mediterranean Cruise Ports and the Coopetition Relationships Between Major Cruise Ports

    Directory of Open Access Journals (Sweden)

    Esteve-Perez Jeronimo

    2018-03-01

    Full Text Available The Mediterranean Sea has seen an increase of ports hosting cruise ships during the first fifteen years of the 21st century. The increase in cruise ship presence in Mediterranean ports is associated with the dynamism of cruise traffic in recent years, with an average annual growth of 7.45% for cruise passengers worldwide during the period of 1990-2015. Cruise traffic is a maritime business that is primarily composed of two elements, maritime affairs and tourism. This article focuses on the maritime component. With the growth of the cruise industry, cruise lines have been forced to seek new ports to meet demand in an attempt to create differentiated products based on the ports that compose the itinerary. The itinerary system of cruise traffic makes the cruise ports depend on one another to design an itinerary. This feature results in both complex geographic relationships in the design of a cruise itinerary and complex competitive/cooperative relationships between ports. The aim of this article is to present the hierarchic picture of a sample of 29 cruise ports in the Western Mediterranean region during the period of 2000-2015. To achieve this goal, a port size classification is proposed and a shift-share analysis at the inter- and intra-group size level is applied. Moreover, concentration measures are used to determine the changes in the levels of market concentration. Furthermore, a dynamic model is proposed to determine the competitive or cooperative relationships between cruise ports. The proposed model is applied to the largest ports with data from the 2001-2015 period.

  2. A four-port launcher for a multi-moded DLDS power distribution system

    International Nuclear Information System (INIS)

    Eppley, K.; Li, Z.; Miller, R.; Nantista, C.; Tantawi, S.

    1998-06-01

    The authors describe a structure for launching the TE 01 and both polarizations of TE 12 modes into a highly overmoded low loss circular waveguide providing remote transmission for a multi-moded Delay Line Distribution System (DLDS). The power from four sources is delivered to four structure ports by rectangular waveguide, and the mode for each pulse subsection is selected by varying the relative phases of the sources. The four ports symmetrically feed a section of waveguide with a fourfold symmetric four-leaf clover-like (or quatrefoil) cross section, dimensioned so as to propagate only four TE modes, characterized as 0, π/2 (two polarizations), and π modes. The 0 and π/2 modes are well matched, the π mode only moderately so. A low loss taper transforms the initial cross section to a circular cross section; the 0 mode transforming to TE 01 , the π/2 to TE 11 , the π to TE 21 , all with negligible mode conversion. A sausage type mode transducer then converts TE 11 to TE 12 (a lower loss mode), and the diameter is then expanded to the full ∼five inch diameter of the delay line. A separate structure to divert power from the last pulse subsection to the local group of accelerator structures is required

  3. Integrated Three-Port DC-DC Converter for Photovoltaic (PV) Battery Stand-alone Systems

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2016-01-01

    of solar energy. Moreover, a novel transformer configuration enables variable turns ratio controlled by the phase between the two current excitations subjected to the primary windings, allowing a wider input/output range. 1 kW experimental prototype has been built to demonstrate a wellmanaged power flow......Several power sources such as PV solar arrays and battery are often used to manage the power flow for a photovoltaic (PV) based stand-alone power system due to the fluctuation nature of solar energy resource, and deliver a continuous power to the users in an appropriate form. Traditionally, three...... different single-input single-output (SISO) dc/dc converters would have been used. To reduce the cost and improve the power density of the system, an integrated three-port isolated dc/dc converter is proposed in this paper. It can realize all functions of the energy delivery due to the fluctuation nature...

  4. Multi-port power router and its impact on resilient power grid systems

    Science.gov (United States)

    Kado, Yuichi; Iwatsuki, Katsumi; Wada, Keiji

    2016-02-01

    We propose a Y-configuration power router as a unit cell to easily construct a power delivery system that can meet many types of user requirements. The Y-configuration power router controls the direction and magnitude of power flow among three ports regardless of DC and AC. We constructed a prototype three-way isolated DC/DC converter that is the core unit of the Y-configuration power router and tested the power flow control operation. Experimental results revealed that our methodology based on the governing equation was appropriate for the power flow control of the three-way DC/DC converter. In addition, the hexagonal distribution network composed of the power routers has the ability to easily interchange electric power between autonomous microgrid cells. We also explored the requirements for communication between energy routers to achieve dynamic adjustments of energy flow in a coordinated manner and its impact on resilient power grid systems.

  5. Repetitive transarterial chemoembolization (rTACE) of hepatocellular carcinoma: comparisons between an arterial port system and conventional angiographic technique

    International Nuclear Information System (INIS)

    Hidajat, Nico; Griesshaber, Volker; Hildebrandt, Bert; Hosten, Norbert; Schroeder, Ralf-Juergen; Felix, Roland

    2004-01-01

    Purpose: To compare the cost and radiation exposure of repetitive transarterial chemoembolization (rTACE) using percutaneously implantable port system with rTACE using conventional catheterization technique. Materials and methods: In five patients with unresectable hepatocellular carcinoma, three cycles of TACE were performed using conventional technique and six cycles using port. The cumulative cost of material and contrast agent and dose area product (DAP) were compared with the cost and DAP that would be expected if the rTACE was performed conventionally. Results: The cost of material and contrast agent was 1002.6 Euro after three cycles of TACE using conventional technique and six cycles using port, but would be 1111.8 Euro if the nine cycles were performed using conventional technique alone. The rTACE with three cycles using conventional technique and six cycles using port led to ∼63% of the cumulative DAP that would be expected in rTACE using conventional technique alone. Conclusion: In rTACE, the use of percutaneously implantable port system might enable a reduction of cost and radiation exposure

  6. SU-F-T-409: Modelling of the Magnetic Port in Temporary Breast Tissue Expanders for a Treatment Planning System

    International Nuclear Information System (INIS)

    Yoon, J; Heins, D; Zhang, R

    2016-01-01

    Purpose: To model the magnetic port in the temporary breast tissue expanders and to improve accuracy of dose calculation in Pinnacle, a commercial treatment planning system (TPS). Methods: A magnetic port in the tissue expander was modeled with a radiological measurement-basis; we have determined the dimension and the density of the model by film images and ion chamber measurement under the magnetic port, respectively. The model was then evaluated for various field sizes and photon energies by comparing depth dose values calculated by TPS (using our new model) and ion chamber measurement in a water tank. Also, the model was further evaluated by using a simplified anthropomorphic phantom with realistic geometry by placing thermoluminescent dosimeters (TLD)s around the magnetic port. Dose perturbations in a real patient’s treatment plan from the new model and a current clinical model, which is based on the subjective contouring created by the dosimetrist, were also compared. Results: Dose calculations based on our model showed less than 1% difference from ion chamber measurements for various field sizes and energies under the magnetic port when the magnetic port was placed parallel to the phantom surface. When it was placed perpendicular to the phantom surface, the maximum difference was 3.5%, while average differences were less than 3.1% for all cases. For the simplified anthropomorphic phantom, the calculated point doses agreed with TLD measurements within 5.2%. By comparing with the current model which is being used in clinic by TPS, it was found that current clinical model overestimates the effect from the magnetic port. Conclusion: Our new model showed good agreement with measurement for all cases. It could potentially improve the accuracy of dose delivery to the breast cancer patients.

  7. USAGE OF STANDARD PERSONAL COMPUTER PORTS FOR DESIGNING OF THE DOUBLE REDUNDANT FAULT-TOLERANT COMPUTER CONTROL SYSTEMS

    Directory of Open Access Journals (Sweden)

    Rafig SAMEDOV

    2005-01-01

    Full Text Available In this study, for designing of the fault-tolerant control systems by using standard personal computers, the ports have been investigated, different structure versions have been designed and the method for choosing of an optimal structure has been suggested. In this scope, first of all, the ÇİFTYAK system has been defined and its work principle has been determined. Then, data transmission ports of the standard personal computers have been classified and analyzed. After that, the structure versions have been designed and evaluated according to the used data transmission methods, the numbers of ports and the criterions of reliability, performance, truth, control and cost. Finally, the method for choosing of the most optimal structure version has been suggested.

  8. A Location-Allocation Model for Seaport-Dry Port System Optimization

    Directory of Open Access Journals (Sweden)

    Xuejun Feng

    2013-01-01

    Full Text Available Seaports participate in hinterland economic development through partnerships with dry ports, and the combined seaport-dry port network serves as the backbone of regional logistics. This paper constructs a location-allocation model for the regional seaport-dry port network optimization problem and develops a greedy algorithm and a genetic algorithm to obtain its solution. This model is applicable to situations under which the geographic distribution of demand is known. A case study involving configuration of dry ports near the west bank of the Taiwan Strait is conducted, and the model is successfully applied.

  9. Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system

    International Nuclear Information System (INIS)

    Tanchuk, Victor; Grigoriev, Sergey; Lyublin, Boris; Maquet, Philippe; Senik, Konstantin; Pak, Sunil; Udintsev, Victor

    2016-01-01

    Highlights: • The cooling system of the ITER Generic Equatorial Port Plug (GEPP) is of a complicated combination of horizontal and vertical channels. • The calculation model for the entire GEPP cooling circuit comprising 12 sub-circuits and built up of 2421 finite-volume elements has been developed. • Transient analysis of this model simulating the draining procedure by the KORSAR/B1 code has been performed. • Water in amount of 263 g of initial 531 kg in the GEPP remains in the dead-ends of the DSM and DFW channels in 150 s of draining procedure. • Almost 3 h are required to boil off 263 g of water trapped in the dead-ends. - Abstract: For effective vacuum leak testing all cooling circuits serving the ITER vessel and in-vessel components shall be drained and dried so that after this procedure taking less than 100 h the purge gas passing through a component has water content less than 100 ppm. This process is four-stage, with the first stage using a short blast of compressed nitrogen to blow most of water in the coolant channels out of the circuit. This process is hindered by volumes which trap water due to gravity. To remove the trapped water, it is necessary, first, to heat up the structure by hot and compressed nitrogen, and then water is evaporated by depressurized nitrogen. The cooling system of the ITER Diagnostic Equatorial Port Plugs is of a complicated hydraulic configuration. The system branching might make difficult removal of water from the piping in the scheduled draining mode. The authors have proposed the KORSAR computation code to simulate draining of the GEPP cooling circuit. The numerical simulation performed has made it possible to describe the process dynamics during draining of the entire GEPP cooling circuit and to define the process time, amount and location of residual water and evolution of two-phase flow regime.

  10. Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Tanchuk, Victor, E-mail: Victor.Tanchuk@sintez.niiefa.spb.su [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Grigoriev, Sergey; Lyublin, Boris [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Maquet, Philippe [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Senik, Konstantin [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Pak, Sunil [National Fusion Research Institute, Daejeon (Korea, Republic of); Udintsev, Victor [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France)

    2016-11-01

    Highlights: • The cooling system of the ITER Generic Equatorial Port Plug (GEPP) is of a complicated combination of horizontal and vertical channels. • The calculation model for the entire GEPP cooling circuit comprising 12 sub-circuits and built up of 2421 finite-volume elements has been developed. • Transient analysis of this model simulating the draining procedure by the KORSAR/B1 code has been performed. • Water in amount of 263 g of initial 531 kg in the GEPP remains in the dead-ends of the DSM and DFW channels in 150 s of draining procedure. • Almost 3 h are required to boil off 263 g of water trapped in the dead-ends. - Abstract: For effective vacuum leak testing all cooling circuits serving the ITER vessel and in-vessel components shall be drained and dried so that after this procedure taking less than 100 h the purge gas passing through a component has water content less than 100 ppm. This process is four-stage, with the first stage using a short blast of compressed nitrogen to blow most of water in the coolant channels out of the circuit. This process is hindered by volumes which trap water due to gravity. To remove the trapped water, it is necessary, first, to heat up the structure by hot and compressed nitrogen, and then water is evaporated by depressurized nitrogen. The cooling system of the ITER Diagnostic Equatorial Port Plugs is of a complicated hydraulic configuration. The system branching might make difficult removal of water from the piping in the scheduled draining mode. The authors have proposed the KORSAR computation code to simulate draining of the GEPP cooling circuit. The numerical simulation performed has made it possible to describe the process dynamics during draining of the entire GEPP cooling circuit and to define the process time, amount and location of residual water and evolution of two-phase flow regime.

  11. Percutaneous implantation of intra-arterial port system for regional drug infusion: results and complications in 110 cases

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Hyuk; Ko, Kyung Hee; Won, Jong Yoon; Park, Sung Il; Lee, Do Yun; Kang, Byung Chul

    2000-01-01

    To investigate the feasibility and complications of a percutaneously implantable port system for regional drug infusion. For intra-arterial drug infusion, a 5.8 or 5-F pediatric venous port system was implanted in 110 patients with hepatocellular carcinoma (n=79), liver metastasis (n=16), gallbladder cancer (n=4), stomach cancer (n=3), pancreatic cancer (n=3), Burger's diseases mellitus (n=2), or lymphoma (n=1). All intra-arterial port implantations were performed percutaneously in an angiographic ward through the common femoral artery (n=98), left subclavian artery (n=10), or left superficial femoral artery (n=2). Complications were evaluated during the follow-up period, which ranged from 21 to 530 (mean, 163) days. The technical success rate for percutaneous implantation of the system was 97.3% (107 of 110 patients). The tips of the port catheter were located in the common hepatic artery (n=34), proper hepatic artery (n=49), right hepatic artery quick resulthepatic artery (n=1), descending aorta at T9 level (n=10), left popliteal artery (n=2), right external iliac artery (n=1), left external iliac artery (n=1), or left deep femoral artery (n=1). Complications were encountered in 24 patients (22.4%), namely chamber site infection (n=7), catheter dislodgement (n=7), catheter occlusion (n=3), migration of coil (n=2), disconnection between chamber and catheter (n=1), kinking of catheter (n=1), arterial occlusion (n=1), necrosis of overlying skin (n=1), and leakage around port chamber (n=1). Outcomes of complications included removal of port systems or cessation of therapy in 12 cases (11.2%), correction of catheter location using a guide wire in five (4.7%), thrombolysis with urokinase in three (2.8%), and straightening using a snare in one (0.9%). In three patients, the port system was used without reintervention. Percutaneous implantation of an intra-arterial port system showed a high technical success rate and a low rate of serious complications. The method may be

  12. Reliability and risk evaluation of a port oil pipeline transportation system in variable operation conditions

    International Nuclear Information System (INIS)

    Soszynska, Joanna

    2010-01-01

    The semi-Markov model of the system operation processes is proposed and its selected characteristics are determined. A system composed on multi-state components is considered and its reliability and risk characteristics are found. Next, the joint model of the system operation process and the system multi-state reliability is applied to the reliability and risk evaluation of the port oil pipeline transportation system. The pipeline system is described and its operation process unknown parameters are identified on the basis of real statistical data. The mean values of the pipeline system operation process unconditional sojourn times in particular operation states are found and applied to determining this process transient probabilities in these states. The piping different reliability structures in various its operation states are fixed and their conditional reliability functions on the basis of data coming from experts are approximately determined. Finally, after applying earlier estimated transient probabilities and system conditional reliability functions in particular operation states the unconditional reliability function, the mean values and standard deviations of the pipeline lifetimes in particular reliability states, risk function and the moment when the risk exceeds a critical value are found.

  13. Reliability and risk evaluation of a port oil pipeline transportation system in variable operation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Soszynska, Joanna, E-mail: joannas@am.gdynia.p [Department of Mathematics, Gdynia Maritime University, ul. Morska 83, 81-225 Gdynia (Poland)

    2010-02-15

    The semi-Markov model of the system operation processes is proposed and its selected characteristics are determined. A system composed on multi-state components is considered and its reliability and risk characteristics are found. Next, the joint model of the system operation process and the system multi-state reliability is applied to the reliability and risk evaluation of the port oil pipeline transportation system. The pipeline system is described and its operation process unknown parameters are identified on the basis of real statistical data. The mean values of the pipeline system operation process unconditional sojourn times in particular operation states are found and applied to determining this process transient probabilities in these states. The piping different reliability structures in various its operation states are fixed and their conditional reliability functions on the basis of data coming from experts are approximately determined. Finally, after applying earlier estimated transient probabilities and system conditional reliability functions in particular operation states the unconditional reliability function, the mean values and standard deviations of the pipeline lifetimes in particular reliability states, risk function and the moment when the risk exceeds a critical value are found.

  14. Case report: treatment of subdural hematoma in the emergency department utilizing the subdural evacuating port system.

    Science.gov (United States)

    Asfora, Wilson T; Klapper, Hendrik B

    2013-08-01

    Patients with acute or chronic subdural hematomas may present with rapidly deteriorating neurological function and are at risk for irreversible brainstem injury. In such cases, rapid surgical intervention is required to evacuate the hematoma and reverse critically elevated intracranial pressure. A variety of surgical drainage methods are in existence, none of which are clearly superior to the others. This report presents the case of a 74-year-old woman who suffered an acute-on-chronic subdural hematoma which was evacuated in the emergency department utilizing the subdural evacuating port system (SEPS). The SEPS provides for a minimally invasive technique to drain subdural hematomas and is advantageous in that it can be performed at the bedside. The SEPS is relatively simple to use and may be especially useful to emergency department staff in outlying areas where there is a shortage of neurosurgical coverage.

  15. Development of a virtual wave buoy system for the Port of Cape Town, South Africa

    CSIR Research Space (South Africa)

    Rossouw, Marius

    2005-07-01

    Full Text Available The Port of Cape Town is located in Table Bay on the south-west coast of South Africa. Since the port experiences advese weather conditions, especially during the winter period, the monitoring of marine weather and wave conditions forms an integral...

  16. A novel optimal coordinated control strategy for the updated robot system for single port surgery.

    Science.gov (United States)

    Bai, Weibang; Cao, Qixin; Leng, Chuntao; Cao, Yang; Fujie, Masakatsu G; Pan, Tiewen

    2017-09-01

    Research into robotic systems for single port surgery (SPS) has become widespread around the world in recent years. A new robot arm system for SPS was developed, but its positioning platform and other hardware components were not efficient. Special features of the developed surgical robot system make good teleoperation with safety and efficiency difficult. A robot arm is combined and used as new positioning platform, and the remote center motion is realized by a new method using active motion control. A new mapping strategy based on kinematics computation and a novel optimal coordinated control strategy based on real-time approaching to a defined anthropopathic criterion configuration that is referred to the customary ease state of human arms and especially the configuration of boxers' habitual preparation posture are developed. The hardware components, control architecture, control system, and mapping strategy of the robotic system has been updated. A novel optimal coordinated control strategy is proposed and tested. The new robot system can be more dexterous, intelligent, convenient and safer for preoperative positioning and intraoperative adjustment. The mapping strategy can achieve good following and representation for the slave manipulator arms. And the proposed novel control strategy can enable them to complete tasks with higher maneuverability, lower possibility of self-interference and singularity free while teleoperating. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Clinical nursing of pelvic neoplasm treated with infusion chemotherapy by using an anti-reflux arterial port-catheter system

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan

    2011-01-01

    Objective: To discuss the clinical nursing care for patients with pelvic neoplasm who were treated with infusion chemotherapy by using an anti-reflux arterial port-catheter system. Methods: After the implantation of an anti-reflux arterial port-catheter system was successfully completed, intra-arterial infusion chemotherapy was carried out in 17 patients with pelvic neoplasm and the infusion chemotherapy was repeated for several times. The pre-procedural clinical nursing care was well done and the technique of proper placement was well grasped. The side effects of chemotherapy drugs and complications were dealt with in time. Medical orientation at discharge time included the protection methods for port-catheter system. Results: Seventeen patients received infusion chemotherapy successfully several times (ranged from 3 to 8 times) with a scheduled regular interval time. No severe complications occurred. No catheter leakage nor obvious irritation and compression symptoms of local skin developed during infusion period. Of the 17 patients, 6 had a complete response, 9 achieved a partial response, while the remaining 2 failed to respond. Conclusion: In accordance with characteristics of infusion chemotherapy by using an anti-reflux arterial port-catheter system, the reasonable and effective nursing care is important to guarantee the achievement of a successful performance and a satisfactory therapeutic result. (authors)

  18. Interconnection and Damping Assignment Passivity-Based Control for Port-Hamiltonian mechanical systems with only position measurements

    NARCIS (Netherlands)

    Dirksz, D. A.; Scherpen, J. M. A.; Ortega, R.

    2008-01-01

    A dynamic extension for position feedback of port-Hamiltonian mechanical systems is studied. First we look at the consequences for the matching equations when applying Interconnection and Damping Assignment Passivity-Based Control (IDA-PBC). Then we look at the possibilities of asymptotically

  19. Low cost, robust and real time system for detecting and tracking moving objects to automate cargo handling in port terminals

    NARCIS (Netherlands)

    Vaquero, V.; Repiso, E.; Sanfeliu, A.; Vissers, J.; Kwakkernaat, M.

    2016-01-01

    The presented paper addresses the problem of detecting and tracking moving objects for autonomous cargo handling in port terminals using a perception system which input data is a single layer laser scanner. A computationally low cost and robust Detection and Tracking Moving Objects (DATMO) algorithm

  20. Port positioning and docking for single-stage totally robotic dissection for rectal cancer surgery with the Si and Xi Da Vinci Surgical System.

    Science.gov (United States)

    Toh, James Wei Tatt; Kim, Seon-Hahn

    2017-11-04

    We have previously reported our technique of single-docking totally robotic dissection for rectal cancer surgery using the Da Vinci ® Si Surgical System in 2009. However, we have since optimised our port placement for the Si system and have developed a novel configuration of port placement and docking for the Da Vinci ® Xi Surgical System. We have performed over 700 cases using this technique with the Si system and have used our Xi technique since 2016 for totally robotic dissection for rectal cancer. We have kept the configuration of port placements for both the Xi and Si system as similar as possible, with the priorities to avoid arm collisions as well as to provide a workable port configuration of two left-handed instruments and one right-handed instrument. To date, there have had no major complications or arm collisions related to this technique of docking, port positioning and instrument placement.

  1. Preparation of dry ports for a competitive environment in the container seaport system: A process benchmarking approach

    Directory of Open Access Journals (Sweden)

    J. Jeevan

    2017-06-01

    Full Text Available The significant exodus of containers inland due to the container revolution has increased the salience of inland terminals for efficient freight distribution. Further, the migration of containers gradually inland has forced seaports to depend on these inland terminals to determine their competitiveness and offer a mechanism for competitive freight price to the consumer. The performance of dry ports need to be improved along with the dynamic nature of maritime business, to efficiently fulfil the demand all the key players in the container seaport system, provide economies of scale and scope to their respective clients and enhances the importance of inland networks to improve and consistently elongate the competitiveness of container seaports. Predicated to these importance, this paper aims to enhance dry port performance by adapting a process benchmarking strategy among the Malaysian dry ports. Prior to the adaptation of the process benchmarking approach, a grounded theory had been conducted as a method of analysis among the key players of the Malaysian container seaport system in order to provide essential inputs for the benchmarking. Through this paper, the outcome shows all four Malaysian dry ports need to improve their transportation infrastructure and operation facilities, container planning strategy, competition, location and externalities in order to assist all the key players in the container seaport system efficiently and effectively.

  2. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (vectorization). Progress report fiscal 1996

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Toshiyuki; Kawai, Wataru [Fujitsu Ltd., Tokyo (Japan); Kawasaki, Nobuo [and others

    1997-12-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the vectorization. In this vectorization part, the vectorization of two and three dimensional discrete ordinates simulation code DORT-TORT, gas dynamics analysis code FLOWGR and relativistic Boltzmann-Uehling-Uhlenbeck simulation code RBUU are described. In the parallelization part, the parallelization of 2-Dimensional relativistic electromagnetic particle code EM2D, Cylindrical Direct Numerical Simulation code CYLDNS and molecular dynamics code for simulating radiation damages in diamond crystals DGR are described. And then, in the porting part, the porting of reactor safety analysis code RELAP5/MOD3.2 and RELAP5/MOD3.2.1.2, nuclear data processing system NJOY and 2-D multigroup discrete ordinate transport code TWOTRAN-II are described. And also, a survey for the porting of command-driven interactive data analysis plotting program IPLOT are described. (author)

  3. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (parallelization). Progress report fiscal 1996

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hideo; Kawai, Wataru; Nemoto, Toshiyuki [Fujitsu Ltd., Tokyo (Japan); and others

    1997-12-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the parallelization. In this parallelization part, the parallelization of 2-Dimensional relativistic electromagnetic particle code EM2D, Cylindrical Direct Numerical Simulation code CYLDNS and molecular dynamics code for simulating radiation damages in diamond crystals DGR are described. In the vectorization part, the vectorization of two and three dimensional discrete ordinates simulation code DORT-TORT, gas dynamics analysis code FLOWGR and relativistic Boltzmann-Uehling-Uhlenbeck simulation code RBUU are described. And then, in the porting part, the porting of reactor safety analysis code RELAP5/MOD3.2 and RELAP5/MOD3.2.1.2, nuclear data processing system NJOY and 2-D multigroup discrete ordinate transport code TWOTRAN-II are described. And also, a survey for the porting of command-driven interactive data analysis plotting program IPLOT are described. (author)

  4. Risk of infection due to medical interventions via central venous catheters or implantable venous access port systems at the middle port of a three-way cock: luer lock cap vs. luer access split septum system (Q-Syte).

    Science.gov (United States)

    Pohl, Fabian; Hartmann, Werner; Holzmann, Thomas; Gensicke, Sandra; Kölbl, Oliver; Hautmann, Matthias G

    2014-01-25

    Many cancer patients receive a central venous catheter or port system prior to therapy to assure correct drug administration. Even appropriate hygienic intervention maintenance carries the risk of contaminating the middle port (C-port) of a three-way cock (TWC), a risk that increases with the number of medical interventions. Because of the complexity of the cleaning procedure with disconnection and reconnection of the standard luer lock cap (referred as "intervention"), we compared luer lock caps with a "closed access system" consisting of a luer access split septum system with regard to process optimization (work simplification, process time), efficiency (costs) and hygiene (patient safety). For determination of process optimization the workflow of an intervention according to the usual practice and risks was depicted in a process diagram. For determining the actual process costs, we analyzed use of material and time parameters per intervention and used the process parameters for programming the process into a simulation run (n = 1000) to determine the process costs as well as their differences (ACTUAL vs. NOMINAL) within the framework of a discrete event simulation.Additionally cultures were carried out at the TWC C-ports to evaluate possible contamination. With the closed access system, the mean working time of 5.5 minutes could be reduced to 2.97 minutes. The results for average process costs (labour and material costs per use) were 3.92 € for luer lock caps and 2.55 € for the closed access system. The hypothesis test (2-sample t-test, CI 0.95, p-valuerisks (related to material, surroundings, staff handling) could be reduced by 65.38%. In the present research, the closed access system with a divided split septum was superior to conventional luer lock caps. The advantage of the closed access system lies in the simplified handling for staff, which results in a reduced risk of patient infection due to improved clinical hygiene.

  5. Intake port

    Science.gov (United States)

    Mendler, Edward Charles

    2005-02-01

    The volumetric efficiency and power of internal combustion engines is improved with an intake port having an intake nozzle, a venturi, and a surge chamber. The venturi is located almost halfway upstream the intake port between the intake valves and the intake plenum enabling the venturi throat diameter to be exceptionally small for providing an exceptionally high ram velocity and an exceptionally long and in turn high efficiency diffuser flowing into the surge chamber. The intake port includes an exceptionally large surge chamber volume for blow down of the intake air into the working cylinder of the engine.

  6. Tools for an integrated systems approach to sustainable port city planning

    OpenAIRE

    Morel,Gilles; Lima,Fernando Rodrigues; Martell-Flores,Hipolito; Hissel,Francois

    2013-01-01

    Large port cities like Shanghai, Amsterdam and Rio de Janeiro are key cogwheels in international logistics and transport networks but also serve as showcases for the rest of the world; as such, they constitute strategic assets for the host country's economy and international infiluence. Historically, a city and its port often developed independently, through sometimes contradictory or even confrontational policies. Today, the growing number of usage disputes over increasingly coveted coastal ...

  7. A Medical Manipulator System with Lasers in Photodynamic Therapy of Port Wine Stains

    Directory of Open Access Journals (Sweden)

    Xingtao Wang

    2014-01-01

    Full Text Available Port wine stains (PWS are a congenital malformation and dilation of the superficial dermal capillary. Photodynamic therapy (PDT with lasers is an effective treatment of PWS with good results. However, because the laser density is uneven and nonuniform, the treatment is carried out manually by a doctor thus providing little accuracy. Additionally, since the treatment of a single lesion can take between 30 and 60 minutes, the doctor can become fatigued after only a few applications. To assist the medical staff with this treatment method, a medical manipulator system (MMS was built to operate the lasers. The manipulator holds the laser fiber and, using a combination of active and passive joints, the fiber can be operated automatically. In addition to the control input from the doctor over a human-computer interface, information from a binocular vision system is used to guide and supervise the operation. Clinical results are compared in nonparametric values between treatments with and without the use of the MMS. The MMS, which can significantly reduce the workload of doctors and improve the uniformity of laser irradiation, was safely and helpfully applied in PDT treatment of PWS with good therapeutic results.

  8. Flow confirmation study for central venous port in oncologic outpatient undergoing chemotherapy: Evaluation of suspected system-related mechanical complications

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Arai, Yasuaki; Takeuchi, Yoshito; Sugimura, Kazuro

    2013-01-01

    Purpose: To evaluate the efficacy and outcome of a flow confirmation study (FCS) in oncologic outpatients undergoing chemotherapy suspected of a central venous port (CVP) system-related mechanical complication. Materials and methods: A total of 66 patients (27 men, 39 women; mean age, 60 years) received FCS for the following reasons: prolonged infusion time during chemotherapy (n = 32), inability to inject saline fluid (n = 15), lateral neck and/or back pain (n = 6), subcutaneous extravasation of anticancer drug (n = 5), arm swelling (n = 4), and inability to puncture the port (n = 4). FCS consisted of examining the position of CVP, potential secondary shifts or fractures, and integrity of the system using contrast material through the port. Results: Of the 66 patients, 43 had an abnormal finding uncovered by FCS. The most frequent abnormal findings was catheter kinking (n = 22). Explantation and reimplantation of the CVP system was required in 21 of the 66 patients. Remaining 45 patients were able continue using the CVP system after the FCS without any system malfunction. Conclusion: FCS was effective for evaluating CVP system-related mechanical complications and was useful for deciding whether CVP system explantation and reimplantation was required

  9. Flow confirmation study for central venous port in oncologic outpatient undergoing chemotherapy: Evaluation of suspected system-related mechanical complications

    Energy Technology Data Exchange (ETDEWEB)

    Sofue, Keitaro, E-mail: ksofue@ncc.go.jp [Divisions of Diagnostic Radiology, National Cancer Center Hospital (Japan); Department of Radiology, Kobe University, Graduate School of Medicine (Japan); Arai, Yasuaki; Takeuchi, Yoshito [Divisions of Diagnostic Radiology, National Cancer Center Hospital (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University, Graduate School of Medicine (Japan)

    2013-11-01

    Purpose: To evaluate the efficacy and outcome of a flow confirmation study (FCS) in oncologic outpatients undergoing chemotherapy suspected of a central venous port (CVP) system-related mechanical complication. Materials and methods: A total of 66 patients (27 men, 39 women; mean age, 60 years) received FCS for the following reasons: prolonged infusion time during chemotherapy (n = 32), inability to inject saline fluid (n = 15), lateral neck and/or back pain (n = 6), subcutaneous extravasation of anticancer drug (n = 5), arm swelling (n = 4), and inability to puncture the port (n = 4). FCS consisted of examining the position of CVP, potential secondary shifts or fractures, and integrity of the system using contrast material through the port. Results: Of the 66 patients, 43 had an abnormal finding uncovered by FCS. The most frequent abnormal findings was catheter kinking (n = 22). Explantation and reimplantation of the CVP system was required in 21 of the 66 patients. Remaining 45 patients were able continue using the CVP system after the FCS without any system malfunction. Conclusion: FCS was effective for evaluating CVP system-related mechanical complications and was useful for deciding whether CVP system explantation and reimplantation was required.

  10. Green Port / Eco Port Project - Applications and Procedures in Turkey

    Science.gov (United States)

    Akgul, Burak

    2017-12-01

    As being the heartlands of international trade, sea ports are the junction points of land and sea routes. The growth of global trade has led to the development of number and capacity as well as the service quality of ports. The policies and procedures applied during construction, operation and development of ports under development with environmental considerations scope has evolved in accordance with the needs of global trends. Although maritime transportation provides the most ecofriendly transportation method, the reduction of potential environmental threats and continuous improvement of ports and their vicinity is paramount from environmental concerns with regards to the international environmental standards. In the context of the study, national and international legal regulations governing the control of the environmental impacts of the activity groups causing pollution in Turkey based sea ports were viewed. In addition, the models applied during the measurement and documentation of environmental impacts were investigated. The most important aspects in terms of the effectiveness of the environmental management models are legal regulations. However, the standards applied at the ports without any legal obligation, such as EcoPorts applications, ISO 14001 standard, and the EMAS (Eco-Management and Audit Scheme) were sought in the scope of the study. The boundaries of the study were determined as the EU based Environmental Management Systems and the Green Port/Eco Port Project which is being administered by the Turkish Ministry of Transport, Maritime and Communication. “Marport”, which is Turkey’s first certified Green Port / Eco Port is designated as the experimental study site. In addition, the provisions in the ports of ESPO member countries are approached in order to compare the effectiveness and applicability of Green Port / Eco Port Project.

  11. Key Performance Indicators Evaluation and Performance Measurement in Dry Port-Seaport System: A Multi Criteria Approach

    Directory of Open Access Journals (Sweden)

    Fatimazahra BENTALEB

    2015-12-01

    Full Text Available Dry port-seaport services are key elements of a multimodal transport. They represent the needed infrastructure for its development. In this case, evaluating and improving their performance is necessary to achieve international competitiveness. The purpose of this paper is to develop a new model of performance measurement for the dry port-seaport system. To this aim, we have consolidated available researches and existing studies in order to identify and develop our proposed model framework. In this paper, a multi-criteria hierarchical model framework using MACBETH for dry port-seaport system has been developed. This framework can be used by managers at different levels of the system. The proposed model has been developed by exploring measurement gaps in multimodal transport field and by discovering prospective options from this area. The results and the methodology are practical. We obtain the global performance level of our involved system using our methodology, which can help managers in taken decisions and increase global performance of this system.

  12. AIDS Diarrhea and Antiretroviral Drug Concentrations: A Matched-Pair Cohort Study in Port au Prince, Haiti

    Science.gov (United States)

    Dillingham, Rebecca; Leger, Paul; Beauharnais, Carole-Anne; Miller, Erica; Kashuba, Angela; Jennings, Steven; Dupnik, Kathryn; Samie, Amidou; Eyma, Etna; Guerrant, Richard; Pape, Jean; Fitzgerald, Daniel

    2011-01-01

    Diarrhea in patients with acquired immunodeficiency syndrome (AIDS) may cause malabsorption of medications and failure of antiretroviral therapy (ART). We prospectively evaluated human immunodeficiency virus-1 (HIV-1)-infected patients with and without chronic diarrhea initiating ART in Haiti. We report mean plasma antiretroviral concentrations at 2 and 4 weeks. We measured plasma HIV-1 RNA levels at four points. Fifty-two HIV-1-infected patients (26 matched pairs) were enrolled. No differences in antiretroviral concentrations were detected. At week 24, 18/25 (72%) cases and 16/24 (68%) controls had undetectable plasma HIV-1 RNA levels (P = 0.69). Patients with plasma HIV-1 RNA levels > 50 copies/mL at week 24 had lower early efavirenz concentrations than patients with undetectable HIV-1 RNA (2,621 ng/mL versus 5,278 ng/mL; P = 0.02). Diarrhea at ART initiation does not influence plasma concentrations of the medications evaluated. Virologic outcome at Week 24 does correlate with efavirenz concentrations early in therapy but not with the presence of chronic diarrhea. PMID:21633022

  13. Uranium concentration monitor manual: 2300 system

    International Nuclear Information System (INIS)

    Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.

    1985-04-01

    This manual describes the design, operation, and procedures for measurement control for the automated uranium concentration monitor on the 2300 solvent extraction system at the Oak Ridge Y-12 Plant. The nonintrusive monitor provides a near-real time readout of uranium concentration at two locations simultaneously in the solvent extraction system for process monitoring and control. Detectors installed at the top of the extraction column and at the bottom of the backwash column acquire spectra of gamma rays from the solvent extraction solutions in the columns. Pulse-height analysis of these spectra gives the concentration of uranium in the organic product of the extraction column and in the aqueous product of the solvent extraction system. The visual readouts of concentrations for process monitoring are updated every 2 min for both detection systems. Simultaneously, the concentration results are shipped to a remote computer that has been installed by Y-12 to demonstrate automatic control of the solvent extraction system based on input of near-real time process operation information. 8 refs., 13 figs., 4 tabs

  14. COMPETITION BETWEEN CONTAINER PORTS IN THE NORTHERN ADRIATIC

    OpenAIRE

    Elen Twrdy; Milan Batista

    2014-01-01

    World trade has changed in the last decade such that container traffic flows are oriented towards more parts of the European continent. The European container port system is not a homogeneous set of ports; instead it consists of several big ports (e.g., Rotterdam, Hamburg, Algeciras...) and a large number of medium and small ports. Northern Adriatic (NA) ports, namely Rijeka, Koper, Trieste, Venice and Ravenna, are small ports. Each of these ports have different development plans but in varyi...

  15. Final design of the generic upper port plug structure for ITER diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sunil, E-mail: paksunil@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Feder, Russell [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Giacomin, Thibaud; Guirao, Julio; Iglesias, Silvia; Josseaume, Fabien [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Kalish, Michael; Loesser, Douglas [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Maquet, Philippe [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Ordieres, Javier; Panizo, Marcos [NATEC, Ingenieros, Gijón (Spain); Pitcher, Spencer; Portalès, Mickael [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Proust, Maxime [CEA, Cadarache, St. Paul-lez-Durance (France); Ronden, Dennis [FOM Institute DIFFER, Nieuwegein (Netherlands); Serikov, Arkady [Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen (Germany); Suarez, Alejandro [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Tanchuk, Victor [NIIEFA, St.-Petersburg (Russian Federation); Udintsev, Victor; Vacas, Christian [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); and others

    2016-01-15

    The generic upper port plug (GUPP) structure in ITER is a 6 m long metal box which deploys diagnostic components into the vacuum vessel. This structure is commonly used for all the diagnostic upper ports. The final design of the GUPP structure, which has successfully passed the final design review in 2013, is described here. The diagnostic port plug is cantilevered to the vacuum vessel with a heavy payload at the front, so called the diagnostic first wall (DFW) and the diagnostic shield module (DSM). Most of electromagnetic (EM) load (∼80%) occurs in DFW/DSM. Therefore, the mounting design to transfer the EM load from DFW/DSM to the GUPP structure is challenging, which should also comply with thermal expansion and tolerance for assembly and manufacturing. Another key design parameter to be considered is the gap between the port plug and the vacuum vessel port. The gap should be large enough to accommodate the remote handling of the heavy port plug (max. 25 t), the structural deflection due to external loads and machine assembly tolerance. At the same time, the gap should be minimized to stop the neutron streaming according to the ALARA (as low as reasonably achievable) principle. With these design constraints, the GUPP structure should also provide space for diagnostic integration as much as possible. This requirement has led to the single wall structure having the gun-drilled water channels inside the structure. Furthermore, intensive efforts have been made on the manufacturing study including material selection, manufacturing codes and French regulation related to nuclear equipment and safety. All these main design and manufacturing aspects are discussed in this paper, including requirements, interfaces, loads and structural assessment and maintenance.

  16. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (vectorization). Progress report fiscal 1997

    International Nuclear Information System (INIS)

    Kawasaki, Nobuo; Ogasawara, Shinobu; Adachi, Masaaki; Kume, Etsuo; Ishizuki, Shigeru; Tanabe, Hidenobu; Nemoto, Toshiyuki; Kawai, Wataru; Watanabe, Hideo

    1999-05-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system and/or the AP3000 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 14 codes in fiscal 1997. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the vectorization. In this vectorization part, the vectorization of multidimensional two-fluid model code ACE-3D for evaluation of constitutive equations, statistical decay code SD and three-dimensional thermal analysis code for in-core test section (T2) of HENDEL SSPHEAT are described. In the parallelization part, the parallelization of cylindrical direct numerical simulation code CYLDNS44N, worldwide version of system for prediction of environmental emergency dose information code WSPEEDI, extension of quantum molecular dynamics code EQMD and three-dimensional non-steady compressible fluid dynamics code STREAM are described. In the porting part, the porting of transient reactor analysis code TRAC-BF1 and Monte Carlo radiation transport code MCNP4A on the AP3000 are described. In addition, a modification of program libraries for command-driven interactive data analysis plotting program IPLOT is described. (author)

  17. Performance Analysis of a Six-Port Receiver in a WCDMA Communication System including a Multipath Fading Channel

    Directory of Open Access Journals (Sweden)

    A. O. Olopade

    2014-01-01

    Full Text Available Third generation communication systems require receivers with wide bandwidth of operation to support high transmission rates and are also reconfigurable to support various communication standards with different frequency bands. An ideal software defined radio (SDR will be the absolute answer to this requirement but it is not achievable with the current level of technology. This paper proposes the use of a six-port receiver (SPR front-end (FE in a WCDMA communication system. A WCDMA end-to-end physical layer MATLAB demo which includes a multipath channel distortion block is used to determine the viability of the six-port based receiver. The WCDMA signal after passing through a multipath channel is received using a constructed SPR FE. The baseband signal is then calibrated and corrected in MATLAB. The six-port receiver performance is measured in terms of bit error rate (BER. The signal-to-noise ratio (SNR of the transmitted IQ data is varied and the BER profile of the communication system is plotted. The effect of the multipath fading on the receiver performance and the accuracy of the calibration algorithm are obtained by comparing two different measured BER curves for different calibration techniques to the simulated BER curve of an ideal receiver.

  18. Construction of a test platform for Test Blanket Module (TBM) systems integration and maintenance in ITER Port Cell #16

    Energy Technology Data Exchange (ETDEWEB)

    Vála, Ladislav, E-mail: ladislav.vala@cvrez.cz [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Reungoat, Mathieu, E-mail: mathieu.reungoat@cvrez.cz [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Vician, Martin [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Poitevin, Yves; Ricapito, Italo; Zmitko, Milan; Panayotov, Dobromir [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain)

    2015-10-15

    Highlights: • A non-nuclear, full size facility – TBM platform – is under construction in CVR. • It is designed for tests, optimization and validation of TBS maintenance operations. • It will allow testing and validation of specific maintenance tools and RH equipment. • It reproduces ITER Port Cell #16, as well as the TBS interfaces and main equipment. • The TBM platform will be available for full operation in the first half of 2016. - Abstract: This paper describes a project of a non-nuclear, 1:1 scale testing platform dedicated to tests, optimization and validation of integration and maintenance operations for the European TBM systems in the ITER Port Cell #16. This TBM platform is currently under construction in Centrum výzkumu Řež, Czech Republic. The facility is realized within the scope of the SUSEN project and its full operation is foreseen in the first half of 2016.

  19. IN VITRO FLOW ANALYSIS OF NOVEL DOUBLE-CUTTING, OPEN-PORT, ULTRAHIGH-SPEED VITRECTOMY SYSTEMS.

    Science.gov (United States)

    Zehetner, Claus; Moelgg, Marion; Bechrakis, Emmanouil; Linhart, Caroline; Bechrakis, Nikolaos E

    2017-10-09

    To analyze the performance and flow characteristics of novel double-cutting, open-port, 23-, 25-, and 27-gauge ultrahigh-speed vitrectomy systems. In vitro fluidic measurements were performed to assess the volumetric aspiration profiles of several vitrectomy systems in basic salt solution and egg white. Double-cutting open-port vitrectomy probes delivered stable aspiration flow rates that were less prone to flow variation affected by the cutting speed. Increase in cutting frequency to the maximum level resulted in flow reduction of less than 10% (0.0%-9.5%). Commercially available 23-, 25-, and 27-G double-cutting probes exhibited higher egg-white and basic salt solution flow rates at all evaluated cut rates, with aspirational efficiencies being 1.1 to 2.9 times the flow rates of standard single-blade vitrectomy probes of the same caliber at the maximum preset vacuum. The highest relative differences were observed at faster cut rates. The newly introduced double-cutting open-port vitrectomy probes delivered stable aspiration flow rates that were less prone to flow variation affected by the cutting speed. The fluidic principle of constant flow even at the highest cut rates and low vacuum levels might impact surgical strategies, especially when performing manipulations close to the retina.

  20. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  1. Impact of the layout of the ITER Radial Neutron Camera in-port system on the measurement of the neutron emissivity profile

    International Nuclear Information System (INIS)

    Marocco, D.; Moro, F.; Esposito, B.; Brolatti, G.; Villari, R.; Salasca, S.; Cantone, B.

    2013-01-01

    Highlights: ► MCNP ITER model ‘Alite-4′ has been updated with the new Port Plug structure (three vertical drawers). ► Two different layouts for the Radial Neutron Camera (RNC) in-vessel system have been considered. ► The impact of both layouts on the RNC diagnostic performance has been assessed. ► The analysis provides useful information for a proper integration of the RNC in the EPP1. -- Abstract: The Radial Neutron Camera (RNC), located in the ITER Equatorial Port Plug 1 (EPP1), is designed to provide the neutron emissivity profile through the measurement of the neutron flux along several collimated channels. The present design of the RNC is based on collimating structures: an ex-port system viewing the plasma core and an in-port system composed by two detector cassettes viewing the upper and lower plasma edges. A design of the EPP1 in which the diagnostics are installed in three completely independent vertical drawers is under study. In this frame, space optimization and integration issues suggest two possible solutions for the layout of the in-port RNC cassettes: the first one in which both cassettes are located in a side drawer; the second one in which the two cassettes lie in the central drawer, on opposite sides of the ex-port RNC cut-out. This paper describes the work performed to assess the impact of the two different in-port system layouts on the capability of the RNC to measure the neutron emissivity profile by means of MCNP and diagnostic performance calculations. The results of the analysis provide guidelines for the integration of the RNC into the EPP1 showing that the proximity of the in-port cassettes to the ex-port cut-out strongly increases the amount of uncollimated and scattered neutrons at the detector positions, thus reducing the diagnostic measurement capability

  2. ITER Upper Port Plug handling cask system assessment and design proposals

    NARCIS (Netherlands)

    Pustjens, J.; Friconneau, J.P.; Heemskerk, C.J.M.; Koning, J.F.; Martins, J.P.; Rosielle, P.C.J.N.; Steinbuch, M.

    2011-01-01

    The current design of the ITER cask for Upper Port Plugs has been evaluated. Careful reduction of the number of mechanical degrees of freedom is an opportunity to relax the tolerances in the design, resulting in cost reduction and reliability increase. A new kinematical design for the tractor module

  3. ITER Upper Port Plug Handling Cask System assessment and design proposals

    NARCIS (Netherlands)

    Pustjens, J.; Friconneau, J.P.; Heemskerk, C.J.M.; Koning, J.F.; Martins, J.P.; Rosielle, P.C.J.N.; Steinbuch, M.

    2010-01-01

    The current design of the ITER Cask for Upper Port Plugs (UPPs) has been evaluated. Careful reduction of the number of mechanical Degrees of Freedom is an opportunity to relax the tolerances in the design, resulting in cost reduction and reliability increase. A new kinematical design for the tractor

  4. Three-port DC-DC converter with new integrated transformer for DC Distribution Systems

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2014-01-01

    A new integrated transformer for three-port dc-dc converter is proposed to overcome the power coupling effect existed in some known multiple inputs dc-dc converters. Orthogonal primary windings arrangement and in series connection of diagonal secondary Windings enables a fully power decoupling...

  5. Ports Primer: 3.2 Port Governance

    Science.gov (United States)

    State and local governments are important players in port governance and in oversight of transportation projects that may affect ports. Private corporations may also play a role if they lease or own a terminal at a port.

  6. A miniature concentrating photovoltaic and thermal system

    International Nuclear Information System (INIS)

    Kribus, Abraham; Kaftori, Daniel; Mittelman, Gur; Hirshfeld, Amir; Flitsanov, Yuri; Dayan, Abraham

    2006-01-01

    A novel miniature concentrating PV (MCPV) system is presented and analyzed. The system is producing both electrical and thermal energy, which is supplied to a nearby consumer. In contrast to PV/thermal (PV/T) flat collectors, the heat from an MCPV collector is not limited to low-temperature applications. The work reported here refers to the evaluation and preliminary design of the MCPV approach. The heat transport system, the electric and thermal performance, the manufacturing cost, and the resulting cost of energy in case of domestic water heating have been analyzed. The results show that the new approach has promising prospects

  7. Robotic Laparoendoscopic Single-site Retroperitioneal Renal Surgery: Initial Investigation of a Purpose-built Single-port Surgical System.

    Science.gov (United States)

    Maurice, Matthew J; Ramirez, Daniel; Kaouk, Jihad H

    2017-04-01

    Robotic single-site retroperitoneal renal surgery has the potential to minimize the morbidity of standard transperitoneal and multiport approaches. Traditionally, technological limitations of non-purpose-built robotic platforms have hindered the application of this approach. To assess the feasibility of retroperitoneal renal surgery using a new purpose-built robotic single-port surgical system. This was a preclinical study using three male cadavers to assess the feasibility of the da Vinci SP1098 surgical system for robotic laparoendoscopic single-site (R-LESS) retroperitoneal renal surgery. We used the SP1098 to perform retroperitoneal R-LESS radical nephrectomy (n=1) and bilateral partial nephrectomy (n=4) on the anterior and posterior surfaces of the kidney. Improvements unique to this system include enhanced optics and intelligent instrument arm control. Access was obtained 2cm anterior and inferior to the tip of the 12th rib using a novel 2.5-cm robotic single-port system that accommodates three double-jointed articulating robotic instruments, an articulating camera, and an assistant port. The primary outcome was the technical feasibility of the procedures, as measured by the need for conversion to standard techniques, intraoperative complications, and operative times. All cases were completed without the need for conversion. There were no intraoperative complications. The operative time was 100min for radical nephrectomy, and the mean operative time was 91.8±18.5min for partial nephrectomy. Limitations include the preclinical model, the small sample size, and the lack of a control group. Single-site retroperitoneal renal surgery is feasible using the latest-generation SP1098 robotic platform. While the potential of the SP1098 appears promising, further study is needed for clinical evaluation of this investigational technology. In an experimental model, we used a new robotic system to successfully perform major surgery on the kidney through a single small

  8. Application of ICT in systems management of the port SME sector

    Directory of Open Access Journals (Sweden)

    Jairo Augusto Cortes Méndez

    2016-06-01

    Full Text Available The project as a result of the research entitled "Impact of ICT in the organizational structure of SMEs in the port sector using virtual environments" under CONADI convening of the Cooperative University of Colombia, measures and verifies how Information Technology and Communication, ICT, have influenced the organizational structure of SMEs (Small and medium enterprises in the port sector, analyzing each of the perspectives and organizational components and how these can be adapted using ICT. As a general conclusion SMEs should be aware of the importance of ICT in the organizational and productive development as an added value and competitive advantage. The draft revision of the organizational theories, management indices, and experiences of use and impact of ICT in organizations was done. The methodology used is observational and evaluative type with technological development.

  9. Engineering issues on the diagnostic port integration in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sunil, E-mail: paksunil@nfri.re.kr [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Bertalot, Luciano [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Cheon, Mun Seong [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Giacomin, Thibaud [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Heemskerk, Cock J.M.; Koning, Jarich F. [Heemskerk Innovative Technology, Merelhof 2, 2172 HZ Sassenheim (Netherlands); Lee, Hyeon Gon [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Nemtcev, Grigorii [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation); Ronden, Dennis M.S. [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Seon, Chang Rae [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Udintsev, Victor; Yukhnov, Nikolay [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Zvonkov, Alexander [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation)

    2016-11-01

    Highlights: • Diagnostic port integration in the upper port 18 of ITER is presented in order to house the three diagnostic systems. • Issue on the neutron shielding in the upper port 18 is addressed and the shut-down dose rate in the interspace is summarized. • The maintenance strategy in the upper port 18 is described. - Abstract: The upper port #18 (UP18) in ITER hosts three diagnostic systems: the neutron activation system, the Vacuum Ultra-Violet spectrometer system, and the vertical neutron camera. These diagnostics are integrated into three infrastructures in the port: the upper port plug, interspace support structure and port cell support structure. The port integration in UP18 is at the preliminary design stage and the current design of the infrastructure as well as the diagnostic integration is described here. The engineering issues related to neutron shielding and maintenance are addressed and the design approach is suggested.

  10. HomePort

    DEFF Research Database (Denmark)

    Le Guilly, Thibaut; Olsen, Petur; Ravn, Anders Peter

    2013-01-01

    Ambient Intelligence systems use many sensors and actuators, with a diversity of networks, protocols and technologies which makes it impossible to access the devices in a common manner. This paper presents the HomePort software, which provides an open source RESTful interface to heterogeneous...... sensor networks, allowing a simple unified access to virtually any kind of protocol using well known standards. HomePort includes means to provide event notification, as well as a tracing mechanism. The software is implemented and we report on initial experiments and provide an evaluation that shows...

  11. Baking system for ports of experimental advanced super-conducting tokamak vacuum vessel and thermal stress analysis

    International Nuclear Information System (INIS)

    Cheng Yali; Bao Liman; Song Yuntao; Yao Damao

    2006-01-01

    The baking system of Experimental Advanced Super-Conducting Toakamk (EAST) vacuum vessel is necessary to obtain the baking temperature of 150 degree C. In order to define suitable alloy heaters and achieve their reasonable layouts, thermal analysis was carried out with ANSYS code. The analysis results indicate that the temperature distribution and thermal stress of most parts of EAST vacuum vessel ports are uniform, satisfied for the requirement, and are safe based on ASME criterion. Feasible idea on reducing the stress focus is also considered. (authors)

  12. Robotic radical perineal cystectomy and extended pelvic lymphadenectomy: initial investigation using a purpose-built single-port robotic system.

    Science.gov (United States)

    Maurice, Matthew J; Kaouk, Jihad H

    2017-12-01

    To assess the feasibility of radical perineal cystoprostatectomy using the latest generation purpose-built single-port robotic surgical system. In two male cadavers the da Vinci ® SP1098 Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) was used to perform radical perineal cystoprostatectomy and bilateral extended pelvic lymph node dissection (ePLND). New features in this model include enhanced high-definition three-dimensional optics, improved instrument manoeuvrability, and a real-time instrument tracking and guidance system. The surgery was accomplished through a 3-cm perineal incision via a novel robotic single-port system, which accommodates three double-jointed articulating robotic instruments, an articulating camera, and an accessory laparoscopic instrument. The primary outcomes were technical feasibility, intraoperative complications, and total robotic operative time. The cases were completed successfully without conversion. There were no accidental punctures or lacerations. The robotic operative times were 197 and 202 min. In this preclinical model, robotic radical perineal cystoprostatectomy and ePLND was feasible using the SP1098 robotic platform. Further investigation is needed to assess the feasibility of urinary diversion using this novel approach and new technology. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  13. Linear concentration system; Sistema de concentracion lineal

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Lugo, J.I; Leon Rovira, N; Aguayo Tellez, H [Instituto Tecnologico y de Estudios Superiores de Monterrey, Monterrey, Nuevo Leon (Mexico)]. E-mails: a00812662@itesm.mx; noel.leon@itesm.mx; haguayo@itesm.mx

    2013-03-15

    Solar linear concentration technologies to generate high temperatures are limited to the ranges of 200 to 500 degrees Celsius. While its performance has been tested through prototypes and pilot plants around the world, there are still areas of opportunity that can be exploited to obtain a linear concentration that achieves temperatures above this range in order to have a better use of the available solar energy. Because of this: It is possible to develop a linear concentration system that can track the sun with minimal movement of the absorber-receiver while maintaining temperatures above 850 degrees Celsius sufficient for industrial processes that require that temperature. The methodology consists of a series of stages (conceptual design, simulation, evaluation, development concept, results and validation) through which concepts are generated that allow design and evaluation of solar concentrator configurations with the help of simulation software. We have designed a linear parabolic concentrating system which comprises a set of mirrors segments with different focal lengths that works within the range of 600 degrees Celsius; however, it is advancing in the development of a double concentration to reach 850 degrees Celsius. [Spanish] Las tecnologias de concentracion lineal solar para generar altas temperaturas se ven limitadas a los rangos de 200 a 500 grados centigrados. Si bien su funcionamiento ha sido probado a traves de prototipos y plantas piloto alrededor del mundo, aun existen areas de oportunidad que pueden ser aprovechadas para obtener un sistema de concentracion lineal que permita alcanzar temperaturas mayores a este rango para asi tener un mejor aprovechamiento de la energia solar disponible. Debido a esto: Es posible desarrollar un sistema de concentracion lineal capaz de seguir la trayectoria del Sol con minimo movimiento del absorbedor-recibidor al mismo tiempo que mantiene temperaturas superiores a los 850 grados centigrados suficientes para

  14. Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

    International Nuclear Information System (INIS)

    Hashimoto, Aya; Tanaka, Toshihiro; Sho, Masayuki; Nishiofuku, Hideyuki; Masada, Tetsuya; Sato, Takeshi; Marugami, Nagaaki; Anai, Hiroshi; Sakaguchi, Hiroshi; Kanno, Masatoshi; Tamamoto, Tetsuro; Hasegawa, Masatoshi; Nakajima, Yoshiyuki; Kichikawa, Kimihiko

    2016-01-01

    PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

  15. Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Aya; Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp [Nara Medical University, Department of Radiology (Japan); Sho, Masayuki [Nara Medical University, Department of Surgery (Japan); Nishiofuku, Hideyuki; Masada, Tetsuya; Sato, Takeshi; Marugami, Nagaaki [Nara Medical University, Department of Radiology (Japan); Anai, Hiroshi [Nara City Hospital, Department of Radiology (Japan); Sakaguchi, Hiroshi [Nara Prefectural Western Medical Center, Department of Radiology (Japan); Kanno, Masatoshi [Nara Medical University, Oncology Center (Japan); Tamamoto, Tetsuro; Hasegawa, Masatoshi [Nara Medical University, Department of Radiation Oncology (Japan); Nakajima, Yoshiyuki [Nara Medical University, Department of Surgery (Japan); Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2016-06-15

    PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

  16. HomePort

    DEFF Research Database (Denmark)

    Madsen, Per Printz

    2009-01-01

    In the last couple of year's computer based home control systems are getting more and more common in modern homes. For instance these systems take care of light control, heat control and security systems.  The latest trend is to use wireless communication like Z-Wave and ZigBee to interconnect...... different components in these systems. One of the characteristics is that each system, like for instance heat and light, has their own specific way of using the communication system.   This paper describes a way to connect different home control systems through an intelligent gateway, called a Home......Port. The HomePort consists of a number of Subsystem communication drivers, a virtual communication layer, an interpreter and a PC- based compiler for a high level control language, called GIL (Gateway intelligence language). The focus in this paper will be on the upper two layers in the Home...

  17. A 'destination port' for the Brazilian electric system. Characteristics of the Brazilian integrated electric systems and forecasting up to the year 2035

    International Nuclear Information System (INIS)

    Alvim, Carlos Feu coord.; Vargas, Jose Israel; Silva, Oothon Luiz Pinheiro da; Ferreira, Omar Campos; Eidelman, Frida

    2005-01-01

    In order to establish a policy for the Electric System in Brazil it is necessary to foresee its future. In a predominantly hydroelectric system where thermal complementation is being introduced, a thirty-year horizon seems to be adequate for forecasting its port of destination and establishing its route to get there. The study describes the existing model, studies its regulation and projects the macro economic scenario, the electricity demand and the necessary generation park. (author)

  18. Designing generalized conic concentrators for conventional optical systems

    Science.gov (United States)

    Eichhorn, W. L.

    1985-01-01

    Generalized nonimaging concentrators can be incorporated into conventional optical systems in situations where flux concentration rather than imaging is required. The parameters of the concentrator for maximum flux concentration depend on the design of the particular optical system under consideration. Rationale for determining the concentrator parameters is given for one particular optical system and the procedure used for calculation of these parameters is outlined. The calculations are done for three concentrators applicable to the optical system.

  19. Determinants of Port Performance - Case Study of 4 Main Ports in Indonesia (2005-2015

    Directory of Open Access Journals (Sweden)

    Atika Aqmarina

    2018-03-01

    Full Text Available Port plays significant role in supporting economic growth of a country. This study aims to analyze the determinant of port performance in Indonesia. In this research, the ports selected are four main ports in Indonesia which are Port of Belawan, Port of Tanjung Priok, Port of Tanjung Perak, and Makassar. These ports are designed as the hub ports in the national sea transport system of the country. The study used pooled OLS as the methodology to analyze the determinant. The result of this studies shows that total traffic is not influenced by operating surplus per ton, whereas the rest of variables such as turnaround time, idle time, berth of occupancy rate, rate of return, number of employee and cargo equipment have significant results and significantly influenced the total traffic.

  20. Synergy-Based Bilateral Port: A Universal Control Module for Tele-Manipulation Frameworks Using Asymmetric Master-Slave Systems.

    Science.gov (United States)

    Brygo, Anais; Sarakoglou, Ioannis; Grioli, Giorgio; Tsagarakis, Nikos

    2017-01-01

    Endowing tele-manipulation frameworks with the capability to accommodate a variety of robotic hands is key to achieving high performances through permitting to flexibly interchange the end-effector according to the task considered. This requires the development of control policies that not only cope with asymmetric master-slave systems but also whose high-level components are designed in a unified space in abstraction from the devices specifics. To address this dual challenge, a novel synergy port is developed that resolves the kinematic, sensing, and actuation asymmetries of the considered system through generating motion and force feedback references in the hardware-independent hand postural synergy space. It builds upon the concept of the Cartesian-based synergy matrix, which is introduced as a tool mapping the fingertips Cartesian space to the directions oriented along the grasp principal components. To assess the effectiveness of the proposed approach, the synergy port has been integrated into the control system of a highly asymmetric tele-manipulation framework, in which the 3-finger hand exoskeleton HEXOTRAC is used as a master device to control the SoftHand, a robotic hand whose transmission system relies on a single motor to drive all joints along a soft synergistic path. The platform is further enriched with the vision-based motion capture system Optitrack to monitor the 6D trajectory of the user's wrist, which is used to control the robotic arm on which the SoftHand is mounted. Experiments have been conducted with the humanoid robot COMAN and the KUKA LWR robotic manipulator. Results indicate that this bilateral interface is highly intuitive and allows users with no prior experience to reach, grasp, and transport a variety of objects exhibiting very different shapes and impedances. In addition, the hardware and control solutions proved capable of accommodating users with different hand kinematics. Finally, the proposed control framework offers a

  1. Three ports versus four ports laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Shah, S.F.; Waqar, S.; Chaudry, M.A.; Hameed, S.

    2017-01-01

    To compare three ports laparoscopic cholecystectomy and four ports laparoscopic cholecystectomy in terms of complications, time taken to complete the procedure, hospital stay and cost effectiveness in local perspective. Methodology: This randomized control trial included 60 patients who underwent elective laparoscopic cholecystectomy at Department of Surgery, Pakistan Institute of Medical Sciences, Islamabad, Pakistan from January 2013 to June 2013. These patients were randomized on computer generated table of random numbers into group A and Group B. In Group A patients four ports were passed to perform laparoscopic cholecystectomy and in Group B patients three ports were passed to perform the procedure. Results: The mean age in both groups was 44 years (range 18-72). Three ports laparoscopic cholecystectomy (43 min) took less time to complete than four ports laparoscopic cholecystectomy (51 min). Patients in three ports laparoscopic cholecystectomy experienced less pain as compared to four ports group. The total additional analgesia requirement in 24 hours calculated in milligrams was less in three port laparoscopic cholecystectomy group as compared four port laparoscopic cholecystectomy group. The mean hospital stay in three port laparoscopic cholecystectomy group is 25 hours while the mean hospital stay in the four port laparoscopic cholecystectomy group is 28 hours. Conclusion: Three ports laparoscopic cholecystectomy is safe and effective procedure and it did not compromise the patient safety. (author)

  2. Concerning background from calorimeter ports

    International Nuclear Information System (INIS)

    Digiacomo, N.J.

    1985-01-01

    Any detector system viewing a port or slit in a calorimeter wall will see, in addition to the primary particles of interest, a background of charged and neutral particles and photons generated by scattering from the port walls and by leakage from incompletely contained primary particle showers in the calorimeter near the port. The signal to noise ratio attainable outside the port is a complex function of the primary source spectrum, the calorimeter and port design and, of course, the nature and acceptance of the detector system that views the port. Rather than making general statements about the overall suitability (or lack thereof) of calorimeter ports, we offer here a specific example based on the external spectrometer and slit of the NA34 experiment. This combination of slit and spectrometer is designed for fixed-target work, so that the primary particle momentum spectrum contains higher momentum particles than expected in a heavy ion colliding beam environment. The results are, nevertheless, quite relevant for the collider case

  3. Principal Ports and Facilities

    Data.gov (United States)

    California Natural Resource Agency — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  4. Principal Ports and Facilities

    Data.gov (United States)

    California Department of Resources — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  5. Solo surgeon single-port laparoscopic surgery with a homemade laparoscope-anchored instrument system in benign gynecologic diseases.

    Science.gov (United States)

    Yang, Yun Seok; Kim, Seung Hyun; Jin, Chan Hee; Oh, Kwoan Young; Hur, Myung Haeng; Kim, Soo Young; Yim, Hyun Soon

    2014-01-01

    The objective of this study was to present the initial operative experience of solo surgeon single-port laparoscopic surgery (SPLS) in the laparoscopic treatment of benign gynecologic diseases and to investigate its feasibility and surgical outcomes. Using a novel homemade laparoscope-anchored instrument system that consisted of a laparoscopic instrument attached to a laparoscope and a glove-wound retractor umbilical port, we performed solo surgeon SPLS in 13 patients between March 2011 and June 2012. Intraoperative complications and postoperative surgical outcomes were determined. The primary operative procedures performed were unilateral salpingo-oophorectomy (n = 5), unilateral salpingectomy (n = 2), adhesiolysis (n = 1), and laparoscopically assisted vaginal hysterectomy (n = 5). Additional surgical procedures included additional adhesiolysis (n = 4) and ovarian drilling (n = 1).The primary indications for surgery were benign ovarian tumors (n = 5), ectopic pregnancy (n = 2), pelvic adhesion (infertility) (n = 1), and benign uterine tumors (n = 5). Solo surgeon SPLS was successfully accomplished in all procedures without a laparoscopic assistant. There were no intraoperative or postoperative complications. Our laparoscope-anchored instrument system obviates the need for an additional laparoscopic assistant and enables SPLS to be performed by a solo surgeon. The findings show that with our system, solo surgeon SPLS is a feasible and safe alternative technique for the treatment of benign gynecologic diseases in properly selected patients. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  6. Port Card Module

    International Nuclear Information System (INIS)

    Utes, M.

    1994-01-01

    The Port Card will be one link in the data acquisition system for the D0 Silicon Vertex Detector. This system consists of the following parts, starting at the detector: Silicon strip detectors are mounted in a spaceframe and wire-bonded to custom bare-die integrated circuits (SVX-II chips) that digitize the charge collected by the strips. The 128-channel chips are mounted on a High-Density Interconnect (HDI) that consists of a small flex circuit that routes control signals and eight data bits for each of three to ten chips onto a common data bus. A cable then routes this bus approximately thirty feet out from the detector to the Port Card. The Port Card houses a commercial chipset that serializes the data in real time and converts the signal into laser light impulses that are then transmitted through a multi-mode optical fiber about 150 feet to a Silicon Acquisition and Readout board (SAR). Here, the data is transformed back to parallel electrical signals that are stored in one of several banks of FIFO memories. The FIFOs place their data onto the VME backplane to a VME Buffer Driver (VBD) which stores the event data in buffers for eventual readout over a thirty-two signal ribbon cable to the Level Two Computers and subsequent tape storage. Control and sequencing of the whole operation starts with the Silicon Acquisition/Readout Controller (SARC) working in tandem with the D0 Clock System. The SARC resides in the same VME crate as the SARs, and transforms signals from the Trigger System into control codes distributed to the various Port Cards via optical fibers operating at 53 Mb/s. It is through these control codes that data taking operations such as data-acquisition, digitization, readout, and various resets can be carried out. The Port Card receives the control codes and manipulates the SVX-II chips in the proper way to effect proper data taking. There will be a total of about 700,000 channels, which translates into about 5580 SVX-II chips, 66 to 100 Port Cards

  7. A Modified Triples Algorithm for Flush Air Data Systems that Allows a Variety of Pressure Port Configurations

    Science.gov (United States)

    Millman, Daniel R.

    2017-01-01

    Air Data Systems (FADS) are becoming more prevalent on re-entry vehicles, as evi- denced by the Mars Science Laboratory and the Orion Multipurpose Crew Vehicle. A FADS consists of flush-mounted pressure transducers located at various locations on the fore-body of a flight vehicle or the heat shield of a re-entry capsule. A pressure model converts the pressure readings into useful air data quantities. Two algorithms for converting pressure readings to air data have become predominant- the iterative Least Squares State Estimator (LSSE) and the Triples Algorithm. What follows herein is a new algorithm that takes advantage of the best features of both the Triples Algorithm and the LSSE. This approach employs the potential flow model and strategic differencing of the Triples Algorithm to obtain the defective flight angles; however, the requirements on port placement are far less restrictive, allowing for configurations that are considered optimal for a FADS.

  8. Preliminary Experience with Locoregional Intraarterial Chemotherapy of Uterine Cervical or Endometrial Cancer Using the Peripheral Implantable Port System (PIPSTM): A Feasibility Study

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Heber, Ralf; Boos, Irene; Goettmann, Dieter; Heinrich, Dirk

    2003-01-01

    The purpose of this study was to assess the suitability of a percutaneously implantable catheter port system (PIPS)for repeated intraarterial locoregional chemotherapy (ILC) for cervical and endometrial carcinoma. In 30 patients with advanced, recurrent, or high-risk cervical (n 23) or endometrial(n = 7) carcinoma, PIPS for ILC was implanted via a femoral access, the catheter localized in the infrarenal abdominal aorta. Chemotherapy was performed adjuvantly after surgery(n = 14) or neo-adjuvantly to enable surgery, or for palliation (n = 16). Port implantation, catheter placement, and repeated port puncture was uneventful in all patients.Complications included catheter dislocation (n = 1),catheter thrombosis (n = 2), subcutaneous infection(n = 1), port-bed skin atrophy (n = 1),requiring port explantation in 3 patients. At 2 years follow-up,complete remission was observed in 7/14 patients with adjuvant chemotherapy, partial remission in 3/14. Successful down-staging could be achieved in 4/8 patients with neo-adjuvant chemotherapy. The PIPS is suitable for repeated ILC which may be a valuable method for pre- and post-surgical therapy of advanced or high-risk cervical and endometrial cancer, for adjuvant chemotherapy as well as neo-adjuvantly for down-staging, or for palliation

  9. Peripheral Insertion of a Central Venous Access Device Under Fluoroscopic Guidance Using a Peripherally Accessed System (PAS) Port in the Forearm

    International Nuclear Information System (INIS)

    Hata, Yasuhiro; Morita, Sojiro; Morita, Yoshitaka; Awatani, Toshihide; Takasaki, Motohiro; Horimi, Tadashi; Ozawa, Zen

    1998-01-01

    Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm. Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route. Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred. Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis

  10. Port of Rotterdam

    NARCIS (Netherlands)

    Veenstra, A.W.

    2014-01-01

    The port of Rotterdam is one of the largest ports in the World and has great significance for the Dutch and European economy. Newly appointed TU/e professor Albert Veenstra explains if and how the Port of Rotterdam is affected by the economic crisis. With other European ports closing in, what can

  11. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Hvolby, Hans-Henrik

    2014-01-01

    While large global ports are recognised as playing a central role in many supply chains as logistic gateways, smaller regional ports have been more stagnant and have not reached the same level of development as the larger ports. The research literature in relation to port development is also...

  12. Port-Wine Stains

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Port-Wine Stains KidsHealth / For Parents / Port-Wine Stains What's ... Manchas de vino de oporto What Are Port-Wine Stains? A port-wine stain is a type ...

  13. Analysis, Design, Modeling, and Control of an Interleaved-Boost Full-Bridge Three-Port Converter for Hybrid Renewable Energy Systems

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Zhang, Zhe; Knott, Arnold

    2017-01-01

    This paper presents the design, modeling, and control of an isolated dc-dc three-port converter (TPC) based on an interleaved-boost full-bridge converter with pulsewidth modulation (PWM) and phase-shift control for hybrid renewable energy systems. In the proposed topology, the switches are driven...

  14. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-05-26

    Disclosed are various embodiments for connectors used with electronic devices, such as input and/or output ports to connect peripheral equipment or accessories. More specifically, various flat-port are provided that can be used in place of standard connectors including, but not limited to, audio jacks and Universal Serial Bus (USB) ports. The flat-port connectors are an alternate connection design to replace the traditional receptacle port (female-port), making the device more sealed creation more dust and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot of space and contribute to the increase thickness of the device. The flat-port receptacle improves the overall appearance of the device and makes it more resistant to dust and water.

  15. Synergy-Based Bilateral Port: A Universal Control Module for Tele-Manipulation Frameworks Using Asymmetric Master–Slave Systems

    Science.gov (United States)

    Brygo, Anais; Sarakoglou, Ioannis; Grioli, Giorgio; Tsagarakis, Nikos

    2017-01-01

    Endowing tele-manipulation frameworks with the capability to accommodate a variety of robotic hands is key to achieving high performances through permitting to flexibly interchange the end-effector according to the task considered. This requires the development of control policies that not only cope with asymmetric master–slave systems but also whose high-level components are designed in a unified space in abstraction from the devices specifics. To address this dual challenge, a novel synergy port is developed that resolves the kinematic, sensing, and actuation asymmetries of the considered system through generating motion and force feedback references in the hardware-independent hand postural synergy space. It builds upon the concept of the Cartesian-based synergy matrix, which is introduced as a tool mapping the fingertips Cartesian space to the directions oriented along the grasp principal components. To assess the effectiveness of the proposed approach, the synergy port has been integrated into the control system of a highly asymmetric tele-manipulation framework, in which the 3-finger hand exoskeleton HEXOTRAC is used as a master device to control the SoftHand, a robotic hand whose transmission system relies on a single motor to drive all joints along a soft synergistic path. The platform is further enriched with the vision-based motion capture system Optitrack to monitor the 6D trajectory of the user’s wrist, which is used to control the robotic arm on which the SoftHand is mounted. Experiments have been conducted with the humanoid robot COMAN and the KUKA LWR robotic manipulator. Results indicate that this bilateral interface is highly intuitive and allows users with no prior experience to reach, grasp, and transport a variety of objects exhibiting very different shapes and impedances. In addition, the hardware and control solutions proved capable of accommodating users with different hand kinematics. Finally, the proposed control framework offers a

  16. Vacuum vessel port structures for ITER-FEAT

    International Nuclear Information System (INIS)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th.

    2001-01-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed

  17. Vacuum vessel port structures for ITER-FEAT

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th

    2001-11-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed.

  18. Experimental characterization of a concentrating photovoltaic system varying the light concentration

    International Nuclear Information System (INIS)

    Renno, C.; Petito, F.; Landi, G.; Neitzert, H.C.

    2017-01-01

    Highlights: • Experimental characterization of a concentrating photovoltaic system. • Analysis of the point-focus concentrating system performances. • Photovoltaic system parameters as function of the concentration factor. - Abstract: The concentrating photovoltaic system represents one of the most promising solar technologies because it allows a more efficient energy conversion. When a CPV system is designed, the main parameter which has to be considered is the concentration factor that affects both the system energy performances and its configuration. An experimental characterization of a CPV system previously realized at the University of Salerno, is presented in this paper considering several aspects related to the optical configuration, the concentration factor and the solar cell used. In particular, the parameters of an Indium Gallium Phosphide/Gallium Arsenide/Germanium triple-junction solar cell are investigated as function of the concentration factor determined by means of an experimental procedure that uses different optical configurations. The maximum concentration factor reached by the CPV system is 310 suns. The cell parameters dependence on the concentration is reported together with an electroluminescence analysis of the Indium Gallium Phosphide/Gallium Arsenide/Germanium cell. A monitoring of the electrical power provided by the system during its working is also presented corresponding to different direct irradiance values. A mean power of 2.95 W with an average efficiency of 32.8% is obtained referring to a mean irradiance of 930 W/m"2; lower values are obtained when the irradiance is highly fluctuating. The concentrating photovoltaic system electric energy output is estimated considering different concentration levels; the maximal obtained value is 23.5 W h on a sunny day at 310×. Finally, the temperature of the triple-junction solar cell is evaluated for different months in order to evaluate the potential annual thermal energy production

  19. EVALUATING THE COMPETITION DYNAMICS OF CONTAINER PORTS IN THE NORTH ADRIATIC

    OpenAIRE

    Twrdy, Elen; Batista, Milan

    2014-01-01

    World trade has changed in the last decade and the container traffic flows are oriented towards several parts of the European continent. A European container port system is not a homogenous set of ports, but is established of several large ports (Rotterdam, Hamburg, Algeciras...) and a large number of medium- and small-sized ports. North Adriatic (NA) ports belong to this category of ports and in this paper we have analysed the container flows and the throughput attained in these ports.

  20. ePORT, NASA's Computer Database Program for System Safety Risk Management Oversight (Electronic Project Online Risk Tool)

    Science.gov (United States)

    Johnson, Paul W.

    2008-01-01

    ePORT (electronic Project Online Risk Tool) provides a systematic approach to using an electronic database program to manage a program/project risk management processes. This presentation will briefly cover the standard risk management procedures, then thoroughly cover NASA's Risk Management tool called ePORT. This electronic Project Online Risk Tool (ePORT) is a web-based risk management program that provides a common framework to capture and manage risks, independent of a programs/projects size and budget. It is used to thoroughly cover the risk management paradigm providing standardized evaluation criterion for common management reporting, ePORT improves Product Line, Center and Corporate Management insight, simplifies program/project manager reporting, and maintains an archive of data for historical reference.

  1. 3D visualization of port simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Horsthemke, W. H.; Macal, C. M.; Nevins, M. R.

    1999-06-14

    Affordable and realistic three dimensional visualization technology can be applied to large scale constructive simulations such as the port simulation model, PORTSIM. These visualization tools enhance the experienced planner's ability to form mental models of how seaport operations will unfold when the simulation model is implemented and executed. They also offer unique opportunities to train new planners not only in the use of the simulation model but on the layout and design of seaports. Simulation visualization capabilities are enhanced by borrowing from work on interface design, camera control, and data presentation. Using selective fidelity, the designers of these visualization systems can reduce their time and efforts by concentrating on those features which yield the most value for their simulation. Offering the user various observational tools allows the freedom to simply watch or engage in the simulation without getting lost. Identifying the underlying infrastructure or cargo items with labels can provide useful information at the risk of some visual clutter. The PortVis visualization expands the PORTSIM user base which can benefit from the results provided by this capability, especially in strategic planning, mission rehearsal, and training. Strategic planners will immediately reap the benefits of seeing the impact of increased throughput visually without keeping track of statistical data. Mission rehearsal and training users will have an effective training tool to supplement their operational training exercises which are limited in number because of their high costs. Having another effective training modality in this visualization system allows more training to take place and more personnel to gain an understanding of seaport operations. This simulation and visualization training can be accomplished at lower cost than would be possible for the operational training exercises alone. The application of PORTSIM and PortVis will lead to more efficient

  2. NOAA’s Physical Oceanographic Real-Time Systems (PORTS(Registered))

    Science.gov (United States)

    2010-06-01

    1 NOAA’s Physical Oceanographic Real - Time Systems (PORTS®) Darren Wright and Robert Bassett National Oceanic and Atmospheric Administration...operation of several Physical Oceanographic Real - Time Systems (PORTS®). 0-933957-38-1 ©2009 MTS Report Documentation Page Form ApprovedOMB No. 0704-0188...TITLE AND SUBTITLE NOAAs Physical Oceanographic Real - Time Systems (PORTS®) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  3. Strategic Mobility 21, Inland Port - Multi-Modal Terminal Operating System Design Specification

    National Research Council Canada - National Science Library

    Mallon, Lawrence G; Dougherty, Edmond J

    2007-01-01

    ...) Specification identifies technical and functional requirements for procuring and integrating services required for a multi-modal node operating software system operating within a Service Oriented Architecture (SOA...

  4. GlobePort Faces Global Business Challenges--Assessing the Organizational Side of Information Systems Projects

    Science.gov (United States)

    Ghosh, Biswadip

    2011-01-01

    Published studies have reported that Information System (IS) projects succeed or fail based on how effectively the organizational issues were understood and addressed in the specification, development and implementation stages of the project. This is particularly true in the design and delivery of Inter-Organizational Systems (IOS) that can affect…

  5. Energy-Shaping of Port-Controlled Hamiltonian Systems by Interconnection

    NARCIS (Netherlands)

    Ortega, Romeo; Schaft, Arjan van der; Maschke, Bernhard; Escobar, Gerardo

    1999-01-01

    Passivity-based control (PBC) has shown to be very powerful to design robust controllers for physical systems described by Euler-Lagrange (EL) equations of motion. The application of PBC in regulation problems of mechanical systems yields controllers that have a clear physical interpretation in

  6. Port Authority Best Practices

    Science.gov (United States)

    Best practices for port authorities include near-port community collaboration, anti-idling policies, expanding off-peak hours, development of EMS, developing an emissions inventory, education, electric power and substituting trucking for rail or barge.

  7. US Ports of Entry

    Data.gov (United States)

    Department of Homeland Security — HSIP Non-Crossing Ports-of-Entry A Port of Entry is any designated place at which a CBP officer is authorized to accept entries of merchandise to collect duties, and...

  8. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-01-01

    and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot

  9. Getting Port Governance Right

    DEFF Research Database (Denmark)

    de Langen, Peter; Saragiotis, Periklis

    2018-01-01

    This chapter discusses the relevance of ports for economic development and next identifies port governance as a critical determinant of a well-functioning port industry. While in the past decades privately owned terminal operating companies have emerged and contributed to more efficient supply ch...

  10. Systems Approach to Defeating Maritime Improvised Explosive Devices in U.S. Ports

    Science.gov (United States)

    2008-12-01

    with a few pounds of explosive in plastic pipes and a timer wrapped in trash bags to keep it afloat. One possible target was presidential hopeful...sonar, laser, gps, control system Benthos Modem Network REMUS reference Bouy WIFI Few equipment and parts N.A 5 3 2 1 5 4 Reliability prediction

  11. GCD TechPort Data Sheets Thermal Protection System Materials (TPSM) Project

    Science.gov (United States)

    Chinnapongse, Ronald L.

    2014-01-01

    The Thermal Protection System Materials (TPSM) Project consists of three distinct project elements: the 3-Dimensional Multifunctional Ablative Thermal Protection System (3D MAT) project element; the Conformal Ablative Thermal Protection System (CA-TPS) project element; and the Heatshield for Extreme Entry Environment Technology (HEEET) project element. 3D MAT seeks to design, develop and deliver a game changing material solution based on 3-dimensional weaving and resin infusion approach for manufacturing a material that can function as a robust structure as well as a thermal protection system. CA-TPS seeks to develop and deliver a conformal ablative material designed to be efficient and capable of withstanding peak heat flux up to 500 W/ sq cm, peak pressure up to 0.4 atm, and shear up to 500 Pa. HEEET is developing a new ablative TPS that takes advantage of state-of-the-art 3D weaving technologies and traditional manufacturing processes to infuse woven preforms with a resin, machine them to shape, and assemble them as a tiled solution on the entry vehicle substructure or heatshield.

  12. Designing Agent Based Inter-Organizational Systems: Business and IOS alignment in the Port of Rotterdam

    NARCIS (Netherlands)

    Douma, A.M.; Moonen, Hans; van Hillegersberg, Jos; van de Rakt, Bastiaan; Schutten, Johannes M.J.

    2006-01-01

    Inter-organizational systems (IOS) hold high promises for improving the coordination of activities in logistics business networks. Although several successful IOS have been implemented, success is scarce in situations where different parties like to keep a large degree of autonomy, are hardly

  13. Porting of the DBCSR library for Sparse Matrix-Matrix Multiplications to Intel Xeon Phi systems

    OpenAIRE

    Bethune, Iain; Gloess, Andeas; Hutter, Juerg; Lazzaro, Alfio; Pabst, Hans; Reid, Fiona

    2017-01-01

    Multiplication of two sparse matrices is a key operation in the simulation of the electronic structure of systems containing thousands of atoms and electrons. The highly optimized sparse linear algebra library DBCSR (Distributed Block Compressed Sparse Row) has been specifically designed to efficiently perform such sparse matrix-matrix multiplications. This library is the basic building block for linear scaling electronic structure theory and low scaling correlated methods in CP2K. It is para...

  14. Deepwater Ports in US waters as of August 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Deepwater Port Licensing Program is the application process designed to promote the construction of LNG and oil deepwater ports. This license system was...

  15. Theoretical and Experimental Studies of a Switched Inertance Hydraulic System in a Four-Port High-Speed Switching Valve Configuration

    Directory of Open Access Journals (Sweden)

    Min Pan

    2017-06-01

    Full Text Available The switched inertance hydraulic system (SIHS is a novel high-bandwidth and energy-efficient digital device which can adjust or control flow and pressure by a means that does not rely on throttling the flow and dissipation of power. An SIHS can provide an efficient step-up or step-down of pressure or flow rate by using a digital control signal. In this article, analytical models of an SIHS in a four-port high-speed switching valve configuration are proposed, and the system dynamics and performance are investigated theoretically and experimentally. The flow responses, system characteristics, and power consumption can be predicted effectively and accurately by using the proposed models, which were validated by comparing with experiments and with numerical simulation. The four-port configuration is compared with the three-port configuration, and it is concluded that the former one is less efficient for valves of the same size, but provides a bi-direction control capability. As bi-direction control is a common requirement, this constitutes an important contribution to the development of efficient digital hydraulics.

  16. Shipping emissions in ports

    OpenAIRE

    Merk, Olaf

    2014-01-01

    Shipping emissions in ports are substantial, accounting for 18 million tonnes of CO2 emissions, 0.4 million tonnes of NOx, 0.2 million of SOx and 0.03 million tonnes of PM10 in 2011. Around 85% of emissions come from containerships and tankers. Containerships have short port stays, but high emissions during these stays. Most of CO2 emissions in ports from shipping are in Asia and Europe (58%), but this share is low compared to their share of port calls (70%). European ports have much less emi...

  17. INSTITUTIONAL AND MANAGEMENT STRUCTURE OF RUSSIAN ARCTIC SEA PORTS

    Directory of Open Access Journals (Sweden)

    P. A. Bryzgalov

    2012-01-01

    Full Text Available Institutional and management structure of any sea port is a system of interaction between commercial enterprises engaged in cargo operations in port, a subsidiary of Rosmorport FSUE, Sea Port Authority and a number of services (immigration, customs and sanitary-veterinary. Institutional and management structure of some Russian Arctic sea ports is significantly different from the typical one resulting in management problems for these socially significant objects of the Russian Arctic. A plan is proposed to improve the organizational and administrative structure of these ports based on the use of domestic and international experience in port infrastructure management including effective cooperation between the state and the private business.

  18. Sea freight - Antwerp Port

    Directory of Open Access Journals (Sweden)

    NEACSU Nicoleta Andreea

    2017-01-01

    Full Text Available Shipping plays a vital role in achieving the movement of goods, both in terms of quantity and efficiency. This paper presents the role and advantages of shipping in the global economy and analyzes the development and Antwerp Port activity. Currently, the second most important trading port in Europe and 14th in the ranking of most important ports that handle containers worldwide, the Port of Antwerp, Belgium is a port in the heart of Europe, accessible to large sized vessels. 200 years of constructing infrastructure and logistics around the central location, as well as pressure from Rotterdam, that had an impact on the competitiveness of the port of Antwerp, all this led the port to occupy a leading position in the top rankings.

  19. Beam-Forming Concentrating Solar Thermal Array Power Systems

    Science.gov (United States)

    Cwik, Thomas A. (Inventor); Dimotakis, Paul E. (Inventor); Hoppe, Daniel J. (Inventor)

    2016-01-01

    The present invention relates to concentrating solar-power systems and, more particularly, beam-forming concentrating solar thermal array power systems. A solar thermal array power system is provided, including a plurality of solar concentrators arranged in pods. Each solar concentrator includes a solar collector, one or more beam-forming elements, and one or more beam-steering elements. The solar collector is dimensioned to collect and divert incoming rays of sunlight. The beam-forming elements intercept the diverted rays of sunlight, and are shaped to concentrate the rays of sunlight into a beam. The steering elements are shaped, dimensioned, positioned, and/or oriented to deflect the beam toward a beam output path. The beams from the concentrators are converted to heat at a receiver, and the heat may be temporarily stored or directly used to generate electricity.

  20. Treatment of stress urinary incontinence after prostatectomy with the adjustable transobturator male system (ATOMS®) with preattached scrotal port.

    Science.gov (United States)

    Esquinas, C; Arance, I; Pamplona, J; Moraga, A; Dorado, J F; Angulo, J C

    2018-04-08

    Stress urinary incontinence (SUI) is a significant sequela of prostate cancer surgery. In this article, we present the surgical technique and safety and efficacy of the adjustable transobturator male system (ATOMS®) with preattached scrotal port. An open prospective study was conducted at a university hospital with the main objective of changing the baseline condition after adjustment in the daily pad count and their wet weight (pad test). The secondary objectives were the quality-of-life assessment (International Consultation on Incontinence Questionnaire-Short Form [ICIQ-SF] and Incontinence Impact Questionnaire-7 [IIQ-7], baseline and after the adjustment), patient-perceived results (Patient Global Index [PGI] and Global Response Assessment [GRA] at 1 year) and assessment of complications according to Clavien-Dindo. The numerical values are expressed in median ± IQR. We analysed 60 consecutive patients with a follow-up of 21±22 months. The baseline pad-test was 465±450mL, and the pad-count was 5+3 pads/day. The baseline SUI was mild (11.6% of patients), moderate (25%) and severe (63.3%). The operative time was 60±25min, the hospital stay was 1±0 days, and the visual analogue scale of pain on day 1 after surgery was 0±1. The total filling was 16.5±7mL, and the number of refillings was 1±2. The pad-test and pad-count after the adjustment were 0±20mL and 0±1, respectively (both pATOMS® is safe and effective in the short-term, even in patients with severe SUI. The rate of dry patients after the adjustment exceeded 80%, and the satisfaction rates exceeded 90%. The patients assessed this treatment highly positively. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Detection and monitoring systems for the prevention of illicit trafficking of radioactive and nuclear materials at sea ports in EU Member States

    International Nuclear Information System (INIS)

    Voorbraak, W.P.; Freudenreich, W.E.; Deurwaarder, C.P.; Kaa, Th. V.D.; Carchon, R.; Baeten, P.; Bruggeman, M.; Holkamp, P.

    1998-01-01

    Illicit trafficking of radioactive and nuclear materials at sea ports may be considered as a serious problem. For this reason, a feasibility study has been carried out in order to investigate the detection possibilities of nuclear materials hidden in cargo which is handled at sea ports. Special attention is given to cargo packed in and transported with freight containers. Detection methods depend upon the measurement of gammas and neutrons, emitted by the nuclear material which is hidden. Detection limits of existing monitoring systems are unknown for geometrical configurations comparable to those specific at sea ports. For this reason calculations were carried out by means of the MCNP-4A Monte Carlo code in order to estimate these detection limits. These calculations are related to passive and active neutron assay, localised gamma sources and contaminated iron scrap. Results of this study are that radioactive materials can be detected without major problems. Passive neutron assay allows the detection of nuclear material in relative small quantities of plutonium in the absence of any deliberate neutron shielding, whereas in the case of dense neutron shielding, detection limits of several kilos of plutonium are obtained. A promising method appears to be a gamma- and neutron monitoring system in combination with an existing X-ray scan installation for cargo verification of container content. The detection probability is further increased when extra intelligence is applied about the origin and route of the cargo. (author)

  2. Dry Port Development: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Fatimazahra BENTALEB

    2015-12-01

    Full Text Available Studies on dry ports as nodes in multimodal transport have been expanded to decrease the mounting congestion on seaports. The principal objective of this study is to inspect how dry port researches have been conducted from different perspective. This paper tries to recap the existing researches that aimed to study dry port concept via a systematic review, to present a general overview of the researches on our relevant region and propose a classification for these researches. This paper present a systematic review of dry port that looks to illustrate the progress of researches on this area between 1986 and 2015, collecting researches on dry port concept and analyzing the main characteristics of the dry port development and their contribution to the multimodal transport. The results indicated that most dry port studies considerate the strategic level and concentrate in the Asian continent. Studies regarding other decision levels and continents have to be developed in further researches. Although the existing studies make a contribution in dry port concept, they allow gaps in terms of operational and tactical decision levels considering their limited geographical region.

  3. Concentrate composition for automatic milking systems - effect on milking frequency

    DEFF Research Database (Denmark)

    Madsen, Jørgen; Weisbjerg, Martin Riis; Hvelplund, Torben

    2010-01-01

    The purpose of this study was to investigate the potential of affecting milking frequency in an Automatic Milking System (AMS) by changing ingredient composition of the concentrate fed in the AMS. In six experiments, six experimental concentrates were tested against a Standard concentrate all...... supplied in the amounts of 5 kg/cow/day. Fifteen cows were fed the experimental concentrate and another 15 cows the Standard concentrate for 14 days and then for the next 14 days the cows were fed the opposite diets to be their own control. The change from one mixture to the next was done over only one day...

  4. Charging systems for waste reception facilities in ports and the level playing field : a case from North-West Europe

    NARCIS (Netherlands)

    Langen, de P.W.; Nijdam, M.H.

    2008-01-01

    Effective coastal zone management requires regulations of various forms. Inevitably, some of these have an impact on seaports. Understandably, regulations that may weaken the competitive position of a seaport are difficult to implement. The stakeholders of ports are well aware of their local,

  5. A Concentrator Photovoltaic System Based on a Combination of Prism-Compound Parabolic Concentrators

    Directory of Open Access Journals (Sweden)

    Ngoc Hai Vu

    2016-08-01

    Full Text Available We present a cost-effective concentrating photovoltaic system composed of a prism and a compound parabolic concentrator (P-CPC. In this approach, the primary collector consists of a prism, a solid compound parabolic concentrator (CPC, and a slab waveguide. The prism, which is placed on the input aperture of CPC, directs the incoming sunlight beam to be parallel with the main axes of parabolic rims of CPC. Then, the sunlight is reflected at the parabolic rims and concentrated at the focal point of these parabolas. A slab waveguide is coupled at the output aperture of the CPC to collect focused sunlight beams and to guide them to the solar cell. The optical system was modeled and simulated with commercial ray tracing software (LightTools™. Simulation results show that the optical efficiency of a P-CPC can achieve up to 89%. when the concentration ratio of the P-CPC is fixed at 50. We also determine an optimal geometric structure of P-CPC based on simulation. Because of the simplicity of the P-CPC structure, a lower-cost mass production process is possible. A simulation based on optimal structure of P-CPC was performed and the results also shown that P-CPC has high angular tolerance for input sunlight. The high tolerance of the input angle of sunlight allows P-CPC solar concentrator utilize a single sun tracking system instead of a highly precise dual suntracking system as cost effective solution.

  6. A multi-port power electronics interface for battery powered electric vehicles: Application of inductively coupled wireless power transfer and hybrid energy storage system

    Science.gov (United States)

    McDonough, Matthew Kelly

    Climate change, pollution, and geopolitical conflicts arising from the extreme wealth concentrations caused by fossil fuel deposits are just a few of the side-effects of the way that we fuel our society. A new method to power our civilization is becoming more and more necessary. Research for new, more sustainable fuel sources is already underway due to research in wind, solar, geothermal, and hydro power. However this focus is mainly on stationary applications. A large portion of fossil fuel usage comes from transportation. Unfortunately, the transition to cleaner transportation fuels is being stunted by the inability to store adequate amounts of energy in electro-chemical batteries. The idea of charging while driving has been proposed by many researchers, however several challenges still exist. In this work some of these challenges are addressed. Specifically, the ability to route power from multiple sources/loads is investigated. Special attention is paid to adjusting the time constant of particular converters, namely the battery and ultra-capacitor converters to reduce the high frequency and high magnitude current components applied to the battery terminals. This is done by developing a closed loop model of the entire multi-port converter, including the state of charge of the ultra-capacitors. The development of closed loop models and two experimental testbeds for use as stationary vehicle charging platforms with their unique set of sources/loads are presented along-side an on-board charger to demonstrate the similarities and differences between stationary charging and mobile charging. Experimental results from each are given showing that it is not only possible, but feasible to utilize Inductively Coupled Wireless Power Transfer (ICWPT) to charge a battery powered electric vehicle while driving and still protect the life-span of the batteries under the new, harsher conditions generated by the ICWPT system.

  7. Development of system on predicting uranium concentration from pregnant solution

    International Nuclear Information System (INIS)

    Yi Weiping

    2004-01-01

    Uranium concentration from pregnant solution is primary index of process for in-situ leaching of uranium, and the suitable method with which to predicate this index and effective means to solve it with were continuously studied hard. SPUC-system on predicting uranium concentration based on GM model of gray system theory is developed, and the mathematical model, constitution, function and theory foundation of this system are introduced. (authors)

  8. The radiation analyses of ITER lower ports

    International Nuclear Information System (INIS)

    Petrizzi, L.; Brolatti, G.; Martin, A.; Loughlin, M.; Moro, F.; Villari, R.

    2010-01-01

    The ITER Vacuum Vessel has upper, equatorial, and lower ports used for equipment installation, diagnostics, heating and current drive systems, cryo-vacuum pumping, and access inside the vessel for maintenance. At the level of the divertor, the nine lower ports for remote handling, cryo-vacuum pumping and diagnostic are inclined downwards and toroidally located each every 40 o . The cryopump port has additionally a branch to allocate a second cryopump. The ports, as openings in the Vacuum Vessel, permit radiation streaming out of the vessel which affects the heating in the components in the outer regions of the machine inside and outside the ports. Safety concerns are also raised with respect to the dose after shutdown at the cryostat behind the ports: in such zones the radiation dose level must be kept below the regulatory limit to allow personnel access for maintenance purposes. Neutronic analyses have been required to qualify the ITER project related to the lower ports. A 3-D model was used to take into account full details of the ports and the lower machine surroundings. MCNP version 5 1.40 has been used with the FENDL 2.1 nuclear data library. The ITER 40 o model distributed by the ITER Organization was developed in the lower part to include the relevant details. The results of a first analysis, focused on cryopump system only, were recently published. In this paper more complete data on the cryopump port and analysis for the remote handling port and the diagnostic rack are presented; the results of both analyses give a complete map of the radiation loads in the outer divertor ports. Nuclear heating, dpa, tritium production, and dose rates after shutdown are provided and the implications for the design are discussed.

  9. Performance investigation of a concentrating photovoltaic/thermal system with transmissive Fresnel solar concentrator

    International Nuclear Information System (INIS)

    Feng, Chaoqing; Zheng, Hongfei; Wang, Rui; Ma, Xinglong

    2016-01-01

    Highlights: • A common design method of a cycloidal transmissive Fresnel solar concentrator was presented. • The gallium arsenide high concentrated solar was used as the receiver. • High efficiency of electric generating could be achieved at noon. • Fresnel solar concentrator was studied and compared in hazy weather and clear weather. - Abstract: A design method of a cycloidal transmissive Fresnel solar concentrator which can provide a certain width focal line was presented in this study. Based on the optical principle of refraction, the dimensions of each wedge-shaped element of Fresnel lens are calculated. An optical simulation has been done to obtain the optical efficiency of the concentrator for different tracking error and axial incidence angle. It has been found that about 80% of the incident sunlight can still be gathered by the absorber when the tracking error is within 0.7°. When the axial angle of incidence is within 10°, it almost has no influence to the receiving rate. The concentrating photovoltaic/thermal system with transmissive Fresnel solar concentrator has been designed in this paper. Take the gallium arsenide high concentrated battery as the receiver, experimental research about cylindrical Fresnel concentrating photovoltaic/thermal system is undertaken in the real sky. Main parameters are tested such as the temperature distribution on receiver, electric energy and thermal energy outputs of concentrating photovoltaic/thermal system, the efficiency of multipurpose utilization of electric and heat, and so on. The test results in clear weather show that maximum electric generating efficiency is about 18% at noon, the maximum heat receiving rate of cooling water is about 45%. At noon time (11:00–13:00), the total efficiency of thermal and electricity can reach more than 55%. Performance of this concentrating photovoltaic/thermal system with transmissive Fresnel solar concentrator is studied and compared in two types typical weather, hazy

  10. Combustion characteristics of a gasoline engine with independent intake port injection and direct injection systems for n-butanol and gasoline

    International Nuclear Information System (INIS)

    He, Bang-Quan; Chen, Xu; Lin, Chang-Lin; Zhao, Hua

    2016-01-01

    Highlights: • Different injection approaches for n-butanol and gasoline affect combustion events. • High n-butanol percentage in the total energy of fuels improves combustion stability. • N-butanol promotes ignition and shortens combustion duration. • Lean burn increases indicated mean effective pressure at fixed total energy of fuels. • Different fuel injection methods slightly affect indicated mean effective pressure. - Abstract: N-butanol, as a sustainable biofuel, is usually used as a blend with gasoline in spark ignition engines. In this study, the combustion characteristics were investigated on a four-cylinder spark ignition gasoline engine with independent port fuel injection and direct injection systems for n-butanol and gasoline in different operating conditions. The results show that in the case of port fuel injection of n-butanol with direct injection gasoline at a given total energy released in a cycle, indicated mean effective pressure is slightly affected by spark timing at stoichiometry while it changes much more with delayed spark timing in lean burn conditions and is much higher in lean burn conditions compared to stoichiometry at given spark timings. With the increase of n-butanol percentage in a fixed total energy released in a cycle at given spark timings, ignition timing advances, combustion duration shortens, indicated mean effective pressure and indicated thermal efficiency increase. For the cases of port fuel injection of n-butanol with direction injection gasoline and port fuel injection of gasoline with direction injection n-butanol at a fixed total energy released in a cycle, their indicated mean effective pressures are close. But their combustion processes are dependent on fuel injection approaches.

  11. Numerical Study of Concentration Characteristics of Linear Fresnel Reflector System

    International Nuclear Information System (INIS)

    Lee, Hyun Jin; Kim, Jong Kyu; Lee, Sang Nam

    2015-01-01

    In this study, we numerically investigated the concentration characteristics of a linear Fresnel reflector system that can drive a solar thermal absorption refrigeration system to be installed in Saudi Arabia. Using an optical modeling program based on the Monte Carlo ray-tracing method, we simulated the concentrated solar flux, concentration efficiency, and concentrated solar energy on four representative days of the year - the vernal equinox, summer solstice, autumnal equinox, and winter solstice. Except the winter solstice, the concentrations were approximately steady from 9 AM to 15 PM, and the concentration efficiencies exceed 70%. Moreover, the maximum solar flux around the solar receiver center changes only within the range of 13.0 - 14.6 kW/m 2 . When we investigated the effects of the receiver installation height, reflector width, and reflector gap, the optimal receiver installation height was found to be 5 m. A smaller reflector width had a greater concentration efficiency. However, the design of the reflector width should be based on the capacity of the refrigeration system because it dominantly affects the concentrated solar energy. The present study was an essential prerequisite for thermal analyses of the solar receiver. Thus, an optical-thermal integration study in the future will assist with the performance prediction and design of the entire system

  12. Numerical Study of Concentration Characteristics of Linear Fresnel Reflector System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Jin [Kookmin Univ., Seoul (Korea, Republic of); Kim, Jong Kyu; Lee, Sang Nam [Korea Institute of Energy Research, Daejeon (Korea, Republic of)

    2015-12-15

    In this study, we numerically investigated the concentration characteristics of a linear Fresnel reflector system that can drive a solar thermal absorption refrigeration system to be installed in Saudi Arabia. Using an optical modeling program based on the Monte Carlo ray-tracing method, we simulated the concentrated solar flux, concentration efficiency, and concentrated solar energy on four representative days of the year - the vernal equinox, summer solstice, autumnal equinox, and winter solstice. Except the winter solstice, the concentrations were approximately steady from 9 AM to 15 PM, and the concentration efficiencies exceed 70%. Moreover, the maximum solar flux around the solar receiver center changes only within the range of 13.0 - 14.6 kW/m{sup 2}. When we investigated the effects of the receiver installation height, reflector width, and reflector gap, the optimal receiver installation height was found to be 5 m. A smaller reflector width had a greater concentration efficiency. However, the design of the reflector width should be based on the capacity of the refrigeration system because it dominantly affects the concentrated solar energy. The present study was an essential prerequisite for thermal analyses of the solar receiver. Thus, an optical-thermal integration study in the future will assist with the performance prediction and design of the entire system.

  13. Dynamic thermal analysis of a concentrated photovoltaic system

    Science.gov (United States)

    Avrett, John T., II; Cain, Stephen C.; Pochet, Michael

    2012-02-01

    Concentrated photovoltaic (PV) technology represents a growing market in the field of terrestrial solar energy production. As the demand for renewable energy technologies increases, further importance is placed upon the modeling, design, and simulation of these systems. Given the U.S. Air Force cultural shift towards energy awareness and conservation, several concentrated PV systems have been installed on Air Force installations across the country. However, there has been a dearth of research within the Air Force devoted to understanding these systems in order to possibly improve the existing technologies. This research presents a new model for a simple concentrated PV system. This model accurately determines the steady state operating temperature as a function of the concentration factor for the optical part of the concentrated PV system, in order to calculate the optimum concentration that maximizes power output and efficiency. The dynamic thermal model derived is validated experimentally using a commercial polysilicon solar cell, and is shown to accurately predict the steady state temperature and ideal concentration factor.

  14. Optical characterization of nonimaging dish concentrator for the application of dense-array concentrator photovoltaic system.

    Science.gov (United States)

    Tan, Ming-Hui; Chong, Kok-Keong; Wong, Chee-Woon

    2014-01-20

    Optimization of the design of a nonimaging dish concentrator (NIDC) for a dense-array concentrator photovoltaic system is presented. A new algorithm has been developed to determine configuration of facet mirrors in a NIDC. Analytical formulas were derived to analyze the optical performance of a NIDC and then compared with a simulated result obtained from a numerical method. Comprehensive analysis of optical performance via analytical method has been carried out based on facet dimension and focal distance of the concentrator with a total reflective area of 120 m2. The result shows that a facet dimension of 49.8 cm, focal distance of 8 m, and solar concentration ratio of 411.8 suns is the most optimized design for the lowest cost-per-output power, which is US$1.93 per watt.

  15. Design and construction of non-imaging planar concentrator for concentrator photovoltaic system

    Energy Technology Data Exchange (ETDEWEB)

    Chong, K.K.; Siaw, F.L.; Wong, C.W.; Wong, G.S. [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Off Jalan Genting Kelang, Setapak, 53300 Kuala Lumpur, Wilayah Persekutuan (Malaysia)

    2009-05-15

    A novel configuration of solar concentrator, which is the non-imaging planar concentrator, capable of producing much more uniform sunlight and reasonably high concentration ratio, is designed and constructed. This design is envisioned to be incorporated in concentrator photovoltaic (CPV) systems. The work presented here reports on the design, optical alignment and application of the prototype, which is installed at Universiti Tunku Abdul Rahman (UTAR), Malaysia. In the architecture of the prototype, 360 flat mirrors, each with a dimension of 4.0 cm x 4.0 cm, are arranged into 24 rows and 15 columns with a total reflection area of about 5760 cm{sup 2}. In addition to that, illumination distribution for the prototype is simulated and its results are then compared with the experiment result. (author)

  16. Complication-related removal of totally implantable venous access port systems: Does the interval between placement and first use and the neutropenia-inducing potential of chemotherapy regimens influence their incidence? A four-year prospective study of 4045 patients.

    Science.gov (United States)

    Kakkos, A; Bresson, L; Hudry, D; Cousin, S; Lervat, C; Bogart, E; Meurant, J P; El Bedoui, S; Decanter, G; Hannebicque, K; Regis, C; Hamdani, A; Penel, N; Tresch-Bruneel, E; Narducci, F

    2017-04-01

    Totally implantable venous access port systems are widely used in oncology, with frequent complications that sometimes necessitate device removal. The aim of this study is to investigate the impact of the time interval between port placement and initiation of chemotherapy and the neutropenia-inducing potential of the chemotherapy administered upon complication-related port removal. Between January 2010 and December 2013, 4045 consecutive patients were included in this observational, single-center prospective study. The chemotherapy regimens were classified as having a low (20%) risk for inducing neutropenia. The overall removal rate due to complications was 7.2%. Among them, port-related infection (2.5%) and port expulsion (1%) were the most frequent. The interval between port insertion and its first use was shown to be a predictive factor for complication-related removal rates. A cut-off of 6 days was statistically significant (p = 0.008), as the removal rate for complications was 9.4% when this interval was 0-5 days and 5.7% when it was ≥6 days. Another factor associated with port complication rate was the neutropenia-inducing potential of the chemotherapy regimens used, with removal for complications involved in 5.5% of low-risk regimens versus 9.4% for the intermediate- and high-risk regimens (p = 0.003). An interval of 6 days between placement and first use of the port reduces the removal rate from complications. The intermediate- and high-risk for neutropenia chemotherapy regimens are related to higher port removal rates from complications than low-risk regimens. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  17. Port Stakeholder Summit: Advancing More Sustainable Ports (April 2014)

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  18. Port Harcourt Medical Journal

    African Journals Online (AJOL)

    Port Harcourt Medical Journal's objectives are to disseminate medical information from the College of Health Sciences, University of Port Harcourt and the rest of the national and international medical community; act as a medium for the articulation of research and findings from same as well as proceedings of medical ...

  19. The Flexible Port

    NARCIS (Netherlands)

    Taneja, P.

    2013-01-01

    Ports are beset with many uncertainties about their futures. They are confronted with new demands in terms of functions and scales, new external constraints, and changed expectations. The inability to adequately meet these demands can mean costly adaptations for a port, or loss of cargo and

  20. Loss Distribution Analysis of a Three-Port Converter for Low-Power Stand-Alone Light-to-Light Systems

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2016-01-01

    In locations far from the equator achieving high conversion efficiency in low-power solar systems is challenging due to low solar irradiance levels. This paper presents a high efficiency three-port converter (TPC) for light-to-light (LtL) applications where no direct solar conversion is required...... demonstrates high efficiency in both power flow paths. At low irradiation level, the power flow from the photovoltaic panel to the battery shows a peak efficiency of 99.1% at at 1.5 W output power, and the LED driver stage presents a peak efficiency of 97.3% at 3 W output power....

  1. Port Stakeholder Summit - April 2014

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  2. Inland Ports in the Republic of Croatia: Approvals for Port Activities instead of Concessions

    Directory of Open Access Journals (Sweden)

    Goran Vojković

    2008-11-01

    Full Text Available According to the 1998 Act on Inland Ports, the right to performall port activities within inland ports of the Republic ofCroatia is given on the basis of concession, obtained throughbidding. It has been noticed in practice that modem businessprocesses and traffic flows are more dynamic than before whenclassic concession relations were created. Also, types andamounts of cargo are changing every couple of years, which isfollowed by quick adjustments, instead of working according torigid and long-term defined decisions and concession contracts.Furthermore, the practice has shown for some activitiesthat the number of port providers (such as ship suppliers,port-agency and freight forwarders should not be limited. Thismeans that the system of a limited number of port providers isimportant only for the activities that require location within aport, as the port area is physically limited. Therefore, the newAct on Navigation and Inland Ports from 2007, whose framehas been completed by sub-law acts during 2008, has replacedthe complex concession system for performing activities in inlandports by a more liberal approval system. On the basis ofthese, higher dynamics of work of port providers is enabled aswell as easier adjustment to market conditions. Furthermore,the main limitation factor that determines the number of portusers becomes the available physical space within a port, whichprovides undisturbed competition, along with larger offer ofport services that do not require that space. It is also importantto point out that the new Act specifically includes distributionand cargo logistics, also processing and improvement of goodsas well as industrial activities including production that enablecomplete economic utilization of port capacities into the existingport activities, thus significantly changing the role of the portitself as a logistic centre.

  3. High-concentration planar microtracking photovoltaic system exceeding 30% efficiency

    Science.gov (United States)

    Price, Jared S.; Grede, Alex J.; Wang, Baomin; Lipski, Michael V.; Fisher, Brent; Lee, Kyu-Tae; He, Junwen; Brulo, Gregory S.; Ma, Xiaokun; Burroughs, Scott; Rahn, Christopher D.; Nuzzo, Ralph G.; Rogers, John A.; Giebink, Noel C.

    2017-08-01

    Prospects for concentrating photovoltaic (CPV) power are growing as the market increasingly values high power conversion efficiency to leverage now-dominant balance of system and soft costs. This trend is particularly acute for rooftop photovoltaic power, where delivering the high efficiency of traditional CPV in the form factor of a standard rooftop photovoltaic panel could be transformative. Here, we demonstrate a fully automated planar microtracking CPV system 660× concentration ratio over a 140∘ full field of view. In outdoor testing over the course of two sunny days, the system operates automatically from sunrise to sunset, outperforming a 17%-efficient commercial silicon solar cell by generating >50% more energy per unit area per day in a direct head-to-head competition. These results support the technical feasibility of planar microtracking CPV to deliver a step change in the efficiency of rooftop solar panels at a commercially relevant concentration ratio.

  4. Fabrication and performance analysis of concentrated hybrid photovoltaic system

    Directory of Open Access Journals (Sweden)

    Murthy Krishna

    2018-01-01

    Full Text Available Sun is the most important source of renewable source of energy. During the past few decades there has been an ever-increasing interest in Photovoltaic (PV cells as it directly converts solar radiation into electricity. This paper involves the performance study of photovoltaic system under concentrated solar radiation. The main problem with the concentration solar energy is the drastic increase in temperature of the photovoltaic module resulting in a decrease in performance efficiency of the system. This problem of overheating of the system can be overcome by providing cooling which would ensure operation of the module in the optimal temperature range. Hence, the setup would function as a hybrid model serving the dual purpose of power generation while also utilizing the waste heat for water heating applications. The experimental set up consist of a novel arrangement of concentrator and reflector and the cooling system. The Hybrid Photovoltaic System was repeatedly tested under real time conditions on several days. A comparison was drawn between the results obtained from direct exposure of a standard photovoltaic module to that obtained from the hybrid system in order to better understand the improvement in performance parameters. The study shown a significant improvement of output of standard photovoltaic module under the concentrated solar radiation.

  5. Laser system for measuring small changes in plasma tracer concentrations.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Galloway, R L; Roselli, R J

    1996-01-01

    The authors developed a laser-diode system that can be used for on-line optical concentration measurements in physiologic systems. Previous optical systems applied to whole blood have been hampered by artifacts introduced by red blood cells (RBCs). The system introduced here uses a commercially available filter cartridge to separate RBCs from plasma before plasma concentration measurements are made at a single wavelength. The filtering characteristics of the Cellco filter cartridge (#4007-10, German-town, MD) were adequate for use in the on-line measurement system. The response time of the filter cartridge was less than 40 seconds, and the sieving characteristics of the filter for macromolecules were excellent, with filtrate-to-plasma albumin ratios of 0.98 +/- 0.11 for studies in sheep and 0.94 +/- 0.15 for studies in dogs. The 635-nm laser diode system developed was shown to be more sensitive than the spectrophotometer used in previous studies (Klaesner et al., Annals of Biomedical Engineering, 1994; 22, 660-73). The new system was used to measure the product of filtration coefficient (Kfc) and reflection coefficient for albumin (delta f) in an isolated canine lung preparation. The delta fKfc values [mL/(cmH2O.min.100 g dry lung weight)] measured with the laser diode system (0.33 +/- 0.22) compared favorably with the delta fKfc obtained using a spectrophotometer (0.27 +/- 0.20) and with the Kfc obtained using the blood-corrected gravimetric method (0.32 +/- 0.23). Thus, this new optical system was shown to accurately measure plasma concentration changes in whole blood for physiologic levels of Kfc. The same system can be used with different optical tracers and different source wavelengths to make optical plasma concentration measurements for other physiologic applications.

  6. Heat Transfer Phenomena in Concentrating Solar Power Systems.

    Energy Technology Data Exchange (ETDEWEB)

    Armijo, Kenneth Miguel; Shinde, Subhash L.

    2016-11-01

    Concentrating solar power (CSP) utilizes solar thermal energy to drive a thermal power cycle for the generation of electricity. CSP systems are facilitated as large, centralized power plants , such as power towers and trough systems, to take advantage of ec onomies of scale through dispatchable thermal energy storage, which is a principle advantage over other energy generation systems . Additionally, the combination of large solar concentration ratios with high solar conversion efficiencies provides a strong o pportunity of employment of specific power cycles such as the Brayton gas cycle that utilizes super critical fluids such as supercritical carbon dioxide (s CO 2 ) , compared to other sola r - fossil hybrid power plants. A comprehensive thermal - fluids examination is provided by this work of various heat transfer phenomena evident in CSP technologies. These include sub - systems and heat transfer fundamental phenomena evident within CSP systems , which include s receivers, heat transfer fluids (HTFs), thermal storage me dia and system designs , thermodynamic power block systems/components, as well as high - temperature materials. This work provides literature reviews, trade studies, and phenomenological comparisons of heat transfer media (HTM) and components and systems, all for promotion of high performance and efficient CSP systems. In addition, f urther investigations are also conducted that provide advanced heat transfer modeling approaches for gas - particle receiver systems , as well as performance/efficiency enhancement re commendations, particularly for solarized supercritical power systems .

  7. The Windows serial port programming handbook

    CERN Document Server

    Bai, Ying

    2004-01-01

    The fundamentals of serial port communications. Serial port programming in ANSI C and Assembly languages for MS-DOS. Serial ports interface developed in VC++ 6.0. Serial port programming in Visual Basic. Serial port programming in LabVIEW. Serial port programming in MATLAB. Serial port programming in Smalltalk. Serial port programming in Java.

  8. COSIMA-ES-PORT

    DEFF Research Database (Denmark)

    Barfod, Michael Bruhn; Leleur, Steen

    2007-01-01

    This article describes the results of the research project – WP3 East-west, Interreg IIIB – concerning the de¬velop¬ment of a new composite decision model, COSIMA-ES-PORT, for the assessment of three pre-feasibility studies situated at the Port of Esbjerg: a road project, a railway project...... and a multimodal terminal. The three studies indicates that a new road connection to the Port of Esbjerg is a very profitable project due to large travel time savings, whereas a new railway connection is not economically viable. However, a new multimodal terminal is also a very profitable project. The COSIMA...

  9. Coastal effects of offshore energy systems. An assessment of oil and gas systems, deepwater ports, and nuclear power plants off the coast of New Jersey and Delaware. Volume II. Parts 1 and 2. Working papers 4 thru 10

    International Nuclear Information System (INIS)

    1976-11-01

    This report consists of ten working papers prepared as background material for the assessment of the effects of three proposed offshore energy systems on the coastal areas of New Jersey and Delaware. The three proposed offshore energy systems are: exploration for and development of offshore oil and gas, deepwater ports for supertankers, and floating nuclear powerplants. The 10 working papers cover: federal and state regulation of the three systems, the biological impacts, the risk of oil spills in developing oil and gas resources and operating deepwater ports, the air and water quality impacts, regional energy supply and demand considerations, the fiscal effects of developing the three systems, environmental studies, a safety analysis of floating nuclear powerplants, an analysis of fuel and waste handling of floating nuclear powerplants, and an analysis of the economic considerations of floating nuclear powerplants

  10. Revisiting port pricing : a proposal for seven port pricing principles

    NARCIS (Netherlands)

    Van Den Berg, R.; De Langen, P.W.; Van Zuijlen, P.C.J.

    2017-01-01

    A review of seven large landlord port authorities around the world reveals a notable diversity of pricing structures. While port authorities increasingly act as commercial undertakings, port pricing often seems to be not driven by commercial considerations. In this paper, we argue that ports can be

  11. Research on variable swirl intake port for high-speed multivalve DI diesel engine. Effects of port configuration on flow characteristics and swirl generation capacity; 4 ben kogata kosoku DI diesel engine no kahen swirl kyuki port ni kansuru kenkyu. Kyuki port haichi ga ryudo tokusei to swirl seino ni oyobosu eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Kawashima, J; Ogawa, H; Tsuru, Y [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    In our previous papers, the variable swirl intake port system which can control a wide swirl ratio range (from 4 to 10) was described. This system consisted of two separate intake ports, one of them has a flow control valve for changing the swirl ratio. In this type of variable swirl system, some variations of port combination, port shape, and position can be designed. In this paper, the intake flow characteristics of various port combinations were analyzed on the basis of a steady-state air flow test and 3-dimensional computations. The results indicate that the total performance of the twin ports can be estimated from that of a single port in any kind of port combination. Some difference in flow patterns were found in a variety of port combinations even if each swirl ratio is similar. The selected port combinations in our previous study are good for a wide swirl control range. 11 refs., 9 figs., 1 tab.

  12. Oluvil Port Development Project

    DEFF Research Database (Denmark)

    Frigaard, Peter; Margheritini, Lucia

    Oluvil Port Development Project is the first development of a large port infrastructure in the entire eastern coastline of Sri Lanka. The project is supported by the Danish Foreign Ministry. Feasibility studies and detailed design studies were carried out by Lanka Hydraulic Institute Ltd during...... the years 1995 to 2003. The design was reviewed by COWI a/s. Construction of the port was started in 2008. MT Højgaard a/s acted as contractor. The outer breakwaters were constructed as first part of the project. During and after completion of the breakwaters a serious beach erosion and sand accumulation...... has been observed. Severe erosion is seen north of the harbour and some accumulation of sand is seen south of the harbour. On a sandy coastline like the one in Oluvil such erosion problems as observed are very typical. The report: Oluvil Port Development Project: Studies on Beach Erosion written...

  13. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  14. Neutronics analysis for integration of ITER diagnostics port EP10

    Energy Technology Data Exchange (ETDEWEB)

    Colling, Bethany, E-mail: bethany.colling@ccfe.ac.uk [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Eade, Tim [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Joyce, Malcolm J. [Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Pampin, Raul; Seyvet, Fabien [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Turner, Andrew [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Udintsev, Victor [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Shutdown dose rate calculations have been performed on an integrated ITER C-lite neutronics model with equatorial port 10. A ‘fully shielded’ configuration, optimised for a given set of diagnostic designs (i.e. shielding in all available space within the port plug drawers), results in a shutdown dose rate in the port interspace, from the activation of materials comprising equatorial port 10, in excess of 2000 μSv/h. Achieving dose rates of 100 μSv/h or less, as required in areas where hands-on maintenance can be performed, in the port interspace region will be challenging. A combination of methods will need to be implemented, such as reducing mass and/or the use of reduced activation steel in the port interspace, optimisation of the diagnostic designs and shielding of the port interspace floor. Further analysis is required to test these options and the ongoing design optimisation of the EP10 diagnostic systems.

  15. Slewing Port Jib Cranes

    OpenAIRE

    Boris Visočnik; Stojan Kravanja

    2002-01-01

    The paper presents slewing port cranes with a luffing jib. The advantages of slewing port jib cranes are high lifting capacities, high speeds of re-loading and excellent mobility since they are capable of load lifting, travelling, luffing and slewing. The paper gives a detailed description of their characteristics such as the highest reached load-carrying capacities, speeds of motion and accelerations. It also presents the crane assembly, driving mechanisms, loads and load cases, transport by...

  16. Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients

    International Nuclear Information System (INIS)

    Goltz, Jan P.; Scholl, Anne; Ritter, Christian O.; Wittenberg, Guenther; Hahn, Dietbert; Kickuth, Ralph

    2010-01-01

    The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days were analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.

  17. β Absorption dust concentration monitor system based on the PLC

    International Nuclear Information System (INIS)

    Lian Dexing; Zhou Xiuliang; Liu Liyan; Li Zonglun; Cao Guanghui; Mao Wanchong

    2011-01-01

    To provide an on-line automatic system for dust concentration monitor is the purpose of this design.The system based on β-ray-absorption-method,employing PLC (Programmable Logic Controller) control technology, is presented. The user input parameter setup,the data acquisition and processing, and the communication with computer can be effectively regulated using the advanced PLC control technology. It has the features of high reliability, easy operation and easy maintenance, and the ability to monitor remotely. Measurement range: 0.1-1500 mg/m 3 , Accuracy: ±9%. The structure,working principle, electric circuit and software development of the system are introduced in detail. (authors)

  18. Simulation and development of a multi-leg homogeniser concentrating assembly for concentrated photovoltaic (CPV) system with electrical rating analysis

    KAUST Repository

    Burhan, Muhammad

    2016-03-09

    Concentrated photovoltaic (CPV) system utilizing multi-junction solar cells, is the main focus for current research, offering highest efficiency among all photovoltaic systems. The main aspect of CPV system is the design and performance of concentrating assembly, as it determines the performance of whole CPV system. However, the conventional design of CPV concentrating assembly dedicates one concentrator for each solar cell, in which single concentrator is capable to concentrate solar radiation onto single solar cell. This paper proposes a novel concentrating assembly for CPV system, which is designed to concentrate solar radiation onto four multi-junction solar cells with a single set of concentrators. The proposed design not only can reduce the number of concentrators and assembly efforts for CPV systems, but also achieved an acceptance angle of 1°. In this paper, the proposed multi-leg homogeniser CPV concentrating assembly is designed, developed, experimentally tested and verified through ray tracing simulation. The paper also discuss the development of mini, precise and accurate but cost effective two axis solar tracker for CPV system, which can be installed at any location even at rooftop of residential buildings, unlike conventional large scale CPV systems. Moreover, through the electrical rating analysis of the developed CPV system, its performance can be accurately estimated in any region. © 2016 Elsevier Ltd. All rights reserved.

  19. Simulation and development of a multi-leg homogeniser concentrating assembly for concentrated photovoltaic (CPV) system with electrical rating analysis

    KAUST Repository

    Burhan, Muhammad; Chua, Kian Jon Ernest; Ng, Kim Choon

    2016-01-01

    Concentrated photovoltaic (CPV) system utilizing multi-junction solar cells, is the main focus for current research, offering highest efficiency among all photovoltaic systems. The main aspect of CPV system is the design and performance of concentrating assembly, as it determines the performance of whole CPV system. However, the conventional design of CPV concentrating assembly dedicates one concentrator for each solar cell, in which single concentrator is capable to concentrate solar radiation onto single solar cell. This paper proposes a novel concentrating assembly for CPV system, which is designed to concentrate solar radiation onto four multi-junction solar cells with a single set of concentrators. The proposed design not only can reduce the number of concentrators and assembly efforts for CPV systems, but also achieved an acceptance angle of 1°. In this paper, the proposed multi-leg homogeniser CPV concentrating assembly is designed, developed, experimentally tested and verified through ray tracing simulation. The paper also discuss the development of mini, precise and accurate but cost effective two axis solar tracker for CPV system, which can be installed at any location even at rooftop of residential buildings, unlike conventional large scale CPV systems. Moreover, through the electrical rating analysis of the developed CPV system, its performance can be accurately estimated in any region. © 2016 Elsevier Ltd. All rights reserved.

  20. Simulation and development of a multi-leg homogeniser concentrating assembly for concentrated photovoltaic (CPV) system with electrical rating analysis

    International Nuclear Information System (INIS)

    Burhan, Muhammad; Chua, Kian Jon Ernest; Ng, Kim Choon

    2016-01-01

    Highlights: • Novel multi-leg homogeniser concentrating assembly is developed for CPV system. • Single set of concentrator, concentrates sunlight on 4 MJCs with 1° acceptance angle. • The system performance is analyzed through experiment and ray tracing simulation. • Mini two axis solar tracker, with high tracking accuracy, is developed and tested. • Electrical rating analysis accurately estimates CPV system performance in any region. - Abstract: Concentrated photovoltaic (CPV) system utilizing multi-junction solar cells, is the main focus for current research, offering highest efficiency among all photovoltaic systems. The main aspect of CPV system is the design and performance of concentrating assembly, as it determines the performance of whole CPV system. However, the conventional design of CPV concentrating assembly dedicates one concentrator for each solar cell, in which single concentrator is capable to concentrate solar radiation onto single solar cell. This paper proposes a novel concentrating assembly for CPV system, which is designed to concentrate solar radiation onto four multi-junction solar cells with a single set of concentrators. The proposed design not only can reduce the number of concentrators and assembly efforts for CPV systems, but also achieved an acceptance angle of 1°. In this paper, the proposed multi-leg homogeniser CPV concentrating assembly is designed, developed, experimentally tested and verified through ray tracing simulation. The paper also discuss the development of mini, precise and accurate but cost effective two axis solar tracker for CPV system, which can be installed at any location even at rooftop of residential buildings, unlike conventional large scale CPV systems. Moreover, through the electrical rating analysis of the developed CPV system, its performance can be accurately estimated in any region.

  1. Data concentrator requirements for a safety parameter display system

    International Nuclear Information System (INIS)

    Brewer, C.R.

    1983-01-01

    To comply with NUREG 0696 several nuclear plants are being fitted with new facilities and data systems; specifically a Technical Support Center (TSC), Operational Support Center (OSC), Emergency Operational Facility (EOF), and Backup Safety Parameter Display System (SPDS), Emergency Response Computer System (ERCS) and Nuclear Data Link (NDL). The TSC, OSC, and EOF are physical locations while the SPDS, ERCS, and NDL are Systems. The SPDS and ERCS are usually separate and independent systems, however, they may share a common front end data acquisition system that acquires and sends SPDS related data to both the SPDS and to the ERCS. In the situation just described an SPDS system must depend upon input data from a source that is SPDS host computer independent. To achieve this independence the front end data acquisition system may employ a concept of intelligent distributed processing. This concept essentially takes functional capabilities that were once found only in realtime host computers and distributes it to front end data acquisition systems. Thus by expanding the functionality of the data acquisition system in a manner that provides more capability, independence from the computer vendor, links to multiple computer systems, processing power and redundancy, the concept of a data concentrator evolved. This paper will define this new distributed functionality, and its related requirements. It will also examine different system configuration approaches

  2. Development of drying and pelletizing system for concentrated waste

    International Nuclear Information System (INIS)

    Horiuchi, Susumu; Saito, Toru; Hirano, Mikio; Kikuchi, Makoto; Takamura, Yoshiyuki.

    1980-01-01

    Volume reduction is strongly required for the radioactive liquid waste generated in nuclear power plants because its storing space has increased with the operating years of the plants, though it has temporarily been stored in drum cans within the plant sites after concentrated by evaporation. The drying and pelletizing system developed by Hitachi, Ltd. in cooperation with Tokyo Electric Power Co. aims at the final disposal by solidifying stored waste after drying, pulverizing, and pelletizing concentrated liquid waste, and storing it in tanks to reduce its radioactivity for the predetermined period. The outstanding features of the system are to be capable of realizing drastic volume reduction and of storing waste as the stable solid in the form flexibly adaptable to any disposing method. The system, to which the new concepts of pulverizing by drying and pelletizing concentrated liquid waste were applied, has been subjected to various fundamental tests and the demonstration tests in a pilot plant during the research and development for 7-years, consequently it was confirmed that the system can be used practically, and the data for designing the equipment for practical use were collected. The items to be considered in designing the equipment for practical use are also mentioned. (Wakatsuki, Y.)

  3. Sensor concentrator unit for the Continuous Automated Vault Inventory System

    International Nuclear Information System (INIS)

    Nodine, R.N.; Lenarduzzi, R.

    1997-06-01

    The purpose of this document is to describe the use and operation of the sensor concentrator in the Continuous Automated Vault Inventory System (CAVIS). The CAVIS electronically verifies the presence of items of stored special nuclear material (SNM). US Department of Energy orders require that stored SNM be inventoried periodically to provide assurance that the material is secure. Currently this inventory is a highly manual activity, requiring personnel to enter the storage vaults. Using a CAVIS allows the frequency of physical inventories to be significantly reduced, resulting in substantial cost savings, increased security, and improved safety. The electronic inventory of stored SNM requires two different types of sensors for each item. The two sensors measure different parameters of the item, usually weight and gamma rays. A CAVIS is constructed using four basic system components: sensors, sensor concentrators, a data collection unit, and a database/user interface unit. One sensor concentrator supports the inventory of up to 20 items (40 sensors) and continuously takes readings from the item sensors. On request the sensor concentrator outputs the most recent sensor readings to the data collection unit. The information transfer takes place over a RS485 communications link. The data collection unit supports from 1 to 120 sensor concentrators (1 to 2,400 items) and is referred to as the Sensor Polling and Configuration System (SPCS). The SPCS is connected by a secure Transmission Control Protocol/Internet Protocol (TCP/IP) network to the database/user interface unit, which is referred to as the Graphical Facility Information Center (GraFIC). A CAVIS containing more than 2,400 items is supported by connecting additional SPCS units to the GraFIC

  4. Sensor concentrator unit for the Continuous Automated Vault Inventory System

    Energy Technology Data Exchange (ETDEWEB)

    Nodine, R.N.; Lenarduzzi, R.

    1997-06-01

    The purpose of this document is to describe the use and operation of the sensor concentrator in the Continuous Automated Vault Inventory System (CAVIS). The CAVIS electronically verifies the presence of items of stored special nuclear material (SNM). US Department of Energy orders require that stored SNM be inventoried periodically to provide assurance that the material is secure. Currently this inventory is a highly manual activity, requiring personnel to enter the storage vaults. Using a CAVIS allows the frequency of physical inventories to be significantly reduced, resulting in substantial cost savings, increased security, and improved safety. The electronic inventory of stored SNM requires two different types of sensors for each item. The two sensors measure different parameters of the item, usually weight and gamma rays. A CAVIS is constructed using four basic system components: sensors, sensor concentrators, a data collection unit, and a database/user interface unit. One sensor concentrator supports the inventory of up to 20 items (40 sensors) and continuously takes readings from the item sensors. On request the sensor concentrator outputs the most recent sensor readings to the data collection unit. The information transfer takes place over a RS485 communications link. The data collection unit supports from 1 to 120 sensor concentrators (1 to 2,400 items) and is referred to as the Sensor Polling and Configuration System (SPCS). The SPCS is connected by a secure Transmission Control Protocol/Internet Protocol (TCP/IP) network to the database/user interface unit, which is referred to as the Graphical Facility Information Center (GraFIC). A CAVIS containing more than 2,400 items is supported by connecting additional SPCS units to the GraFIC.

  5. Process and overview of diagnostics integration in ITER ports

    International Nuclear Information System (INIS)

    Drevon, J.M.; Walsh, M.; Andrew, P.; Barnsley, R.; Bertalot, L.; Bock, M. de; Bora, D.; Bouhamou, R.; Direz, M.F.; Encheva, A.; Fang, T.; Feder, R.; Giacomin, T.; Hellermann, M. von; Jakhar, S.; Johnson, D.; Kaschuk, Y.; Kusama, Y.; Lee, H.G.; Levesy, B.

    2013-01-01

    Highlights: ► An overview of the Port Integration hardware for tenant system hosting inside ITER diagnostics ports is given. ► The main challenges for diagnostic port integration engineering are presented. ► The actions taken for a common modular approach and a coordinated design are detailed. -- Abstract: ITER will have a set of 45 diagnostics to ensure controlled operation. Many of them are integrated in the ITER ports. This paper addresses the integration process of the diagnostic systems and the approach taken to enable coordinated progress. An overview of the Port Integration hardware introduces the various structures needed for hosting tenant systems inside ITER diagnostics ports. The responsibilities of the different parties involved (ITER Organization and the Domestic Agencies) are outlined. The main challenges for diagnostic port integration engineering are summarized. The plan for a common approach to design and manufacture of the supporting structures, in particular the Port Plug is detailed. A coordinated design including common components and a common approach for neutronic analyses is proposed. One particular port, the equatorial port 11, is used to illustrate the approach

  6. Strategic Planning for Port Development: Improvement of Container Transit from the Iranian Southern Ports Terminals

    Directory of Open Access Journals (Sweden)

    Homayoun Yousefi

    2013-09-01

    Full Text Available The author attempts to highlight the significance of the Iranian southern ports development strategy planning which allows for the maximum container transit with minimum resources such as service capacities, human resources, and financial potential in order to expand the Iranian container transit. It should be noted that the strategic objectives, the business strategy and its implementation can be arranged only after the port vision and mission obviously delineated. For the purpose of improving the outcome of the ports operational management, it is recommended to concentrate on new strategies such as exploit of transit corridors for development of the Iranian South Ports. The main part of this paper is dedicated to evaluate the role of container transit from the Iranian south ports terminals from various transport corridors in order to improve Maritime Transport in Iran. The importance of defin¬ing the existing and potential competitors at the Persian Gulf and making a comparison between their and our own strengths and weaknesses is of utmost importance. Sometimes, the real business opportunities and threats are placed beyond one’s own line of indus¬try and business. It is therefore necessary to make a careful analysis of the port environment. After the port competition and environment have been analyzed, it would be possible to initiate the building of the SWOT analysis for the Iranian Southern Container Terminals such as Khoramshahr, Imam Khomani, Busher, Bandar Abbas and Chabahar port which have suitable strategic position as transit base in the region. The SWOT analysis method is therefore applied aiming at defining the weaknesses and strengths of the economic subjects as well as opportunities and threats coming from the environment. The next segment of this paper is dedicated to consider the role of dry ports and the International North-South Transit Corridor for the purpose of improving the Iranian container trade.

  7. Use of Subdural Evacuating Port System Following Open Craniotomy with Excision of Native Dura and Membranes for Management of Chronic Subdural Hematoma.

    Science.gov (United States)

    Cage, Tene; Bach, Ashley; McDermott, Michael W

    2017-04-26

    An 86-year-old woman was admitted to the intensive care unit with a chronic subdural hematoma (CSDH) and rapid onset of worsening neurological symptoms. She was taken to the operating room for a mini-craniotomy for evacuation of the CSDH including excision of the dura and CSDH membrane. Postoperatively, a subdural evacuation port system (SEPS) was integrated into the craniotomy site and left in place rather than a traditional subdural catheter drain to evacuate the subdural space postoperatively. The patient had a good recovery and improvement of symptoms after evacuation and remained clinically well after the SEPS was removed. We offer the technique of dura and CSDH membrane excision plus SEPS drain as an effective postoperative alternative to the standard craniotomy leaving the native dura intact with traditional subdural drain that overlies the cortical surface of the brain in treating patients with CSDH.

  8. J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system

    International Nuclear Information System (INIS)

    Hama, Yukihiro; Kusano, Shoichi; Makita, Kohzoh

    2004-01-01

    The aim of this study was to verify the feasibility of using a J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system (RPCS). Twenty-five patients with various hepatic malignancies underwent percutaneous implantation of an RPCS through the left subclavian artery for regional chemotherapy. To successfully puncture the left subclavian artery, a J-tipped guidewire was used as a target with fluoroscopic guidance. Technical success and complication rates, and numbers of puncture failures, were retrospectively analyzed. Implantation of the RPCS was successful in all patients. Eight (32%) patients had minor complications and no patient had major complications. The number of puncture failures per patient was 0 to 1 (mean=0.32). The J-tipped guidewire is a safe and appropriate target for puncture of the subclavian artery in the placement of an RPCS. (orig.)

  9. Source apportionment of PM{sub 10} utilising Automatic Cartridge Collection Unit (ACCU) and TEOM systems in Neath Port Talbot

    Energy Technology Data Exchange (ETDEWEB)

    Hooper, M.J.; Hollingsworth, P. [Neath Port Talbot Borough Council, Neath Port Talbot (United Kingdom); Stone, I.M.; Merefield, J.R. [Exeter Univ., Earth Resources Centre, Exeter (United Kingdom)

    1999-10-01

    The background to this study is the review and assessment of air quality as required by Part IV of the Environment Act 1995. A detailed emissions inventory indicated that there might be a significant problem with PM{sub 10} in the Taibach/Margam area of Port Talbot. This was confirmed by continuous monitoring data from the Automatic Urban Network site in the area at Groeswen hospital. These data, when coupled with wind direction data, enabled the production of pollution roses that showed that the highest average PM{sub 10} levels occurred when the wind was blowing towards the residential area from a large significant local source in the west and south-west, i.e. a steel works. The Council is carrying out a stage 3 assessment of PM{sub 10} in this area with a high probability that an Air Quality Management Action Area (AQMA) will need to be declared. It has therefore become clear, that in order to be able to proceed sensibly to an action plan and attempt to meet Air Quality Objectives, identification of the contribution of PM{sub 10} from specific sources would be required. Initial fingerprinting studies were carried out in partnership with Exeter university and, at an early stage, an Air Quality Management Working Group was formed with the works and the Environment Agency to enable constructive dialogue to take place. (Author)

  10. Classification and prediction of port variables

    Energy Technology Data Exchange (ETDEWEB)

    Molina Serrano, B.

    2016-07-01

    Many variables are included in planning and management of port terminals. They can beeconomic, social, environmental and institutional. Agent needs to know relationshipbetween these variables to modify planning conditions. Use of Bayesian Networks allowsfor classifying, predicting and diagnosing these variables. Bayesian Networks allow forestimating subsequent probability of unknown variables, basing on know variables.In planning level, it means that it is not necessary to know all variables because theirrelationships are known. Agent can know interesting information about how port variablesare connected. It can be interpreted as cause-effect relationship. Bayesian Networks can beused to make optimal decisions by introduction of possible actions and utility of theirresults.In proposed methodology, a data base has been generated with more than 40 port variables.They have been classified in economic, social, environmental and institutional variables, inthe same way that smart port studies in Spanish Port System make. From this data base, anetwork has been generated using a non-cyclic conducted grafo which allows for knowingport variable relationships - parents-children relationships-. Obtained network exhibits thateconomic variables are – in cause-effect terms- cause of rest of variable typologies.Economic variables represent parent role in the most of cases. Moreover, whenenvironmental variables are known, obtained network allows for estimating subsequentprobability of social variables.It has been concluded that Bayesian Networks allow for modeling uncertainty in aprobabilistic way, even when number of variables is high as occurs in planning andmanagement of port terminals. (Author)

  11. Dynamic behavior of a multi-effect sugar concentrator system

    International Nuclear Information System (INIS)

    Aly, N.H.; Marwan, M.A.

    1994-01-01

    A transient mathematical model is developed to simulate the dynamic response of multi effect evaporator for sugar distiller concentrators at delta company, Egypt. Based on the mass and energy balance equations, a non linear mathematical model relating the system variables is obtained. This model allows to investigate the response of the unit parameters in both steady state and transient operating condition. Also, the response of the unit to perturbations in feed syrup, flow rate, concentration and heating steam temperature is studied. The predicted response based on the solution of the mathematical model is illustrated. The developed model proved to be efficient and capable to predict different operating conditions at steady state or transients variations. The study shows that an increase in heating steam temperature can be a critical factor due to caramelization of the syrup. 1 tab., 10 fig

  12. Slewing Port Jib Cranes

    Directory of Open Access Journals (Sweden)

    Boris Visočnik

    2002-09-01

    Full Text Available The paper presents slewing port cra11es with a luffing jib.The advantages of slewing port jib cranes are high lifting capacities,high speeds of re-loading and excellent mobility since theyare capable of load lifting, travelling, luffing and slewing. Thepaper gives a detailed description of their characteristics suchas the highest reached load-canying capacities, speeds of motionand accelerations. It also presents the crane assembly,driving mechanisms, loads and load cases, transport by shipsand testing of lifting capacity. As a practical example the paperpresents the slewing port jib crane with the capacity of25!15!5 tat a 27/37/40 m radius made by the Slovenian companyMetalna Maribor for the shipyard 3. Maj, Rijeka, Croatia.

  13. Modeling the performance of low concentration photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    Reis, F. [SESUL, Faculdade de Ciencias da Universidade de Lisboa, 1749-016 Lisboa (Portugal); WS Energia, Ed. Tecnologia II 47, Taguspark, Oeiras (Portugal); Brito, M.C. [SESUL, Faculdade de Ciencias da Universidade de Lisboa, 1749-016 Lisboa (Portugal); Corregidor, V.; Wemans, J. [WS Energia, Ed. Tecnologia II 47, Taguspark, Oeiras (Portugal); Sorasio, G. [WS Energia, Ed. Tecnologia II 47, Taguspark, Oeiras (Portugal); Centro Richerche ISCAT, VS Pellico, 12037, Saluzzo (Italy)

    2010-07-15

    A theoretical model has been developed to describe the response of V-trough systems in terms of module temperature, power output and energy yield using as inputs the atmospheric conditions. The model was adjusted to DoubleSun {sup registered} concentration technology, which integrates dual-axis tracker and conventional mono-crystalline Si modules. The good agreement between model predictions and the results obtained at WS Energia laboratory, Portugal, validated the model. It is shown that DoubleSun {sup registered} technology increases up to 86% the yearly energy yield of conventional modules relative to a fixed flat-plate system. The model was also used to perform a sensitivity analysis, in order to highlight the relevance of the leading working parameters (such as irradiance) in system performance (energy yield and module temperature). Model results show that the operation module temperature is always below the maximum working temperature defined by the module manufacturers. (author)

  14. A web-based screening tool for near-port air quality assessments

    Science.gov (United States)

    The Community model for near-PORT applications (C-PORT) is a screening tool with an intended purpose of calculating differences in annual averaged concentration patterns and relative contributions of various source categories over the spatial domain within about 10 km of the port...

  15. A Mixed Integer Programming for Port Anzali Development Plan

    OpenAIRE

    Mahdieh Allahviranloo

    2009-01-01

    This paper introduces a mixed integer programming model to find the optimum development plan for port Anzali. The model minimizes total system costs taking into account both port infrastructure costs and shipping costs. Due to the multipurpose function of the port, the model consists of 1020 decision variables and 2490 constraints. Results of the model determine the optimum number of berths that should be constructed in each period and for each type of cargo. In addition to, the results of se...

  16. Monitoring electrolyte concentrations in redox flow battery systems

    Science.gov (United States)

    Chang, On Kok; Sopchak, David Andrew; Pham, Ai Quoc; Kinoshita, Kimio

    2015-03-17

    Methods, systems and structures for monitoring, managing electrolyte concentrations in redox flow batteries are provided by introducing a first quantity of a liquid electrolyte into a first chamber of a test cell and introducing a second quantity of the liquid electrolyte into a second chamber of the test cell. The method further provides for measuring a voltage of the test cell, measuring an elapsed time from the test cell reaching a first voltage until the test cell reaches a second voltage; and determining a degree of imbalance of the liquid electrolyte based on the elapsed time.

  17. Structure preserving port-Hamiltonian model reduction of electrical circuits

    NARCIS (Netherlands)

    Polyuga, R.; Schaft, van der A.J.; Benner, P.; Hinze, M.; Maten, ter E.J.W.

    2011-01-01

    This paper discusses model reduction of electrical circuits based on a port-Hamiltonian representation. It is shown that by the use of the Kalman decomposition an uncontrollable and/or unobservable port-Hamiltonian system is reduced to a controllable/observable system that inherits the

  18. Airborne fibre and asbestos concentrations in system built schools

    Science.gov (United States)

    Burdett, Garry; Cottrell, Steve; Taylor, Catherine

    2009-02-01

    This paper summarises the airborne fibre concentration data measured in system built schools that contained asbestos insulation board (AIB) enclosed in the support columns by a protective steel casing. The particular focus of this work was the CLASP (Consortium of Local Authorities Special Programme) system buildings. A variety of air monitoring tests were carried out to assess the potential for fibres to be released into the classroom. A peak release testing protocol was adopted that involved static sampling, while simulating direct impact disturbances to selected columns. This was carried out before remediation, after sealing gaps and holes in and around the casing visible in the room (i.e. below ceiling level) and additionally round the tops of the columns, which extended into the suspended ceiling void. Simulated and actual measurements of worker exposures were also undertaken, while sealing columns, carrying out cleaning and maintenance work in the ceiling voids. Routine analysis of these air samples was carried out by phase contrast microscopy (PCM) with a limited amount of analytical transmission electron microscopy (TEM) analysis to confirm whether the fibres visible by PCM were asbestos or non-asbestos. The PCM fibre concentrations data from the peak release tests showed that while direct releases of fibres to the room air can occur from gaps and holes in and around the column casings, sealing is an effective way of minimising releases to below the limit of quantification (0.01 f/ml) of the PCM method for some 95% of the tests carried out. Sealing with silicone filler and taping any gaps and seams visible on the column casing in the room, also gave concentrations below the limit of quantification (LOQ) of the PCM method for 95% of the tests carried out. The data available did not show any significant difference between the PCM fibre concentrations in the room air for columns that had or had not been sealed in the ceiling void, as well as in the room

  19. Airborne fibre and asbestos concentrations in system built schools

    International Nuclear Information System (INIS)

    Burdett, Garry; Cottrell, Steve; Taylor, Catherine

    2009-01-01

    This paper summarises the airborne fibre concentration data measured in system built schools that contained asbestos insulation board (AIB) enclosed in the support columns by a protective steel casing. The particular focus of this work was the CLASP (Consortium of Local Authorities Special Programme) system buildings. A variety of air monitoring tests were carried out to assess the potential for fibres to be released into the classroom. A peak release testing protocol was adopted that involved static sampling, while simulating direct impact disturbances to selected columns. This was carried out before remediation, after sealing gaps and holes in and around the casing visible in the room (i.e. below ceiling level) and additionally round the tops of the columns, which extended into the suspended ceiling void. Simulated and actual measurements of worker exposures were also undertaken, while sealing columns, carrying out cleaning and maintenance work in the ceiling voids. Routine analysis of these air samples was carried out by phase contrast microscopy (PCM) with a limited amount of analytical transmission electron microscopy (TEM) analysis to confirm whether the fibres visible by PCM were asbestos or non-asbestos. The PCM fibre concentrations data from the peak release tests showed that while direct releases of fibres to the room air can occur from gaps and holes in and around the column casings, sealing is an effective way of minimising releases to below the limit of quantification (0.01 f/ml) of the PCM method for some 95% of the tests carried out. Sealing with silicone filler and taping any gaps and seams visible on the column casing in the room, also gave concentrations below the limit of quantification (LOQ) of the PCM method for 95% of the tests carried out. The data available did not show any significant difference between the PCM fibre concentrations in the room air for columns that had or had not been sealed in the ceiling void, as well as in the room

  20. Sources and contamination rate of port sediments: evidences from dimensional, mineralogical, and chemical investigations

    Science.gov (United States)

    Lucchetti, Gabriella; Cutroneo, Laura; Carbone, Cristina; Consani, Sirio; Vagge, Greta; Canepa, Giuseppe; Capello, Marco

    2017-04-01

    Ports are complex environments due to their complicated geometry (quays, channels, and piers), the presence of human activities (vessel traffic, yards, industries, and discharges), and natural factors (stream and torrent inputs, sea action, and currents). Due to the many activities that take place in a port, sediments and waters are often contaminated by different kinds of chemicals, such as hydrocarbons, dioxins, pesticides, nutrients, and metals. The contamination rate of a port basin is site specific and depends on the sources of contamination in the nearby urban system as well as the port system itself, such as city discharges and sewers, river intake, vessel traffic, factories (Taylor and Owens, 2009). Moreover, two important sources and vehicles of contaminants are: a) anthropogenic road deposited sediments derived from the runoff of the port and city area, and natural road deposited sediments derived from rivers and torrents, and b) airborne particulate matter and sediments (Taylor and Owens, 2009). The Port of Genoa is situated at the apex of the Ligurian Sea in the north western Mediterranean Sea and is characterised by the presence of several commercial activities that have contributed, over the years, and still contribute today, to the contaminant accumulation in both the water column and the bottom sediments. This port basin includes the mouth of several streams and the mouth of the Bisagno and the Polcevera Torrents, along the banks of which can be found several small towns, quarries, factories, and the suburbs of the city of Genoa, a ferry terminal, different container terminals, marinas, dry docks, the coal power plant of Genoa, and different wastewater treatment plant discharges. Starting from these considerations, we have examined the marine environment of a port from the point of view of the water mass circulation, hydrological characteristics, distribution of the sediment grain size, mineralogical characteristics, and metal concentrations of the

  1. Optimum Design Of Grid Connected Photovoltaic System Using Concentrators

    Directory of Open Access Journals (Sweden)

    Eng. Mohammed Fawzy

    2015-08-01

    Full Text Available Abstract Due to the increasing demand of electrical energy in Egypt and also in many neighboring countries around the world the main problem facing electrical energy production using classical methods such steam power stations is the depletion of fossil fuels. The gap between the electrical energy demand and the continuous increase on the fossil fuel cost make the problem of electricity generation more sophisticated. With the continuous decrease of the photovoltaic PV technologies cost it doesnt make sense neglecting the importance of electricity production using solar photovoltaic PV especially that the annual average daily energy received is about 6 kamp12310whmamp123112day in Cairo Egypt 30N.In this work a detailed simulation model including photovoltaic PV module characteristics and climatic conditions of Cairo Egypt is developed. The model compares fixed PV systems electrical energy output with photovoltaic PV system using concentrators and double axis tracker systems. The comparison includes the energy generated area required as well as the cost per kwh generated. The optimality criterion is the cost per kwh generated. The system that gives the minimum cost per kwh is the optimum system. To verify the developed model the simulation results of fixed PV modules and CPV using tracking system obtained by the model are compared with practical measurements of 40KW peak station erected in Cairo Egypt 30N.Very good agreement between measured values and results obtained from detailed simulation model. For fixed PV system the detailed economic analysis showed that it gives minimum cost perkwh generated Comparisons among these systems are presented. For Cairo results showed that a cost of about 6 to 9 US centskwh is attainable.

  2. Solar water disinfecting system using compound parabolic concentrating collector

    Energy Technology Data Exchange (ETDEWEB)

    El-Ghetany, H.H.; Saitoh, T.S. [Tohoku Univ., Sendai (Japan)

    2000-05-31

    Solar water disinfection is an alternative technology using solar radiation and thermal treatment to inactivate and destroy pathogenic microorganisms present in water. The Compound Parabolic Concentrating, (CPC) collector can be used as an efficient key component for solar disinfectanting system. Two types of the CPC collectors are studied, namely the transparent-tube and the Copper-tube CPC collector. It is found that after 30 minutes of exposing the water sample to solar radiation or heating it up to 65 degree C for a few minuets all the coliform bacterial present in the contaminated water sample were completely eliminated. In this article, the effect of water temperature on the disinfecting process was presented. Thermal and micro-biological measurements were also made to evaluate the system performance. (author)

  3. Evaluation of Background Mercury Concentrations in the SRS Groundwater System

    International Nuclear Information System (INIS)

    Looney, B.B.

    1999-01-01

    Mercury analyses associated with the A-01 Outfall have highlighted the importance of developing an understanding of mercury in the Savannah River Site groundwater system and associated surface water streams. This activity is critical based upon the fact that the EPA Ambient Water Quality Criteria (AWQC) for this constituent is 0.012mg/L, a level that is well below conventional detection limits of 0.1 to 0.2 mg/L. A first step in this process is obtained by utilizing the existing investment in groundwater mercury concentrations (20,242 records) maintained in the SRS geographical information management system (GIMS) database. Careful use of these data provides a technically defensible initial estimate for total recoverable mercury in background and contaminated SRS wells

  4. Gentamicin concentration gradients in scala tympani perilymph following systemic applications.

    Science.gov (United States)

    Hahn, Hartmut; Salt, Alec N; Schumacher, Ulrike; Plontke, Stefan K

    2013-01-01

    It has been shown in prior studies that round window membrane (RWM) application of gentamicin produced a robust basal-apical concentration gradient in the perilymph of scala tympani (ST) with peak concentrations in the basal turn of ST. These gradients potentially contribute to the clinical efficacy and safety of intratympanic gentamicin applications for the treatment of Ménière's disease. The present study aimed to establish the distribution of gentamicin along ST perilymph after systemic applications. Gentamicin sulfate was applied intravenously in the amounts of 100, 300 and 600 mg/kg body weight (BW) over a period of 3 h or as a 300 mg/kg BW subcutaneous bolus injection. At 3 and 5 h after the start of the application perilymph of ST was aspirated from the cochlea apex of the right and left cochlea, respectively, and 10 sequential 1-µl perilymph samples from the apex of each cochlea were quantitatively analyzed using a fluorescence polarization immunoassay. In contrast to local RWM delivery, systemic application of gentamicin resulted in the highest perilymph levels in the apex of the cochlea with decreasing concentrations towards the basal regions of ST. The absolute gentamicin concentrations increased with the amount of drug applied and time before sampling. While it is likely that the basal-apical gradient measured after local drug applications to the round window niche is the result of the direct uptake of drugs into the perilymph of the ST, distribution by diffusion and a very low perilymph flow towards the cochlear apex, computer simulations suggested that the apical-basal gradient observed with these systemic applications can be explained by higher entry rates of gentamicin in the apex compared to the basal turns of the cochlea. It is also possible that gentamicin enters perilymph indirectly from the blood via the endolymph. In this case the faster kinetics in apical turns could be due to the smaller cross-sectional area of ST relative to endolymph in

  5. Port entry arrangements

    International Nuclear Information System (INIS)

    Chicken, J.C.; King, M.A.

    1978-01-01

    The objective of the paper is to describe the safety scheme port authorities should establish to deal with any contingency that may result from the visit of a nuclear powered ship. The safety scheme should be devised to cover both normal operation and any accident conditions that could arise while the ship is in port. The paper is divided into three parts. The three parts being: background information, general instructions, and emergency procedures. The background information will describe the nature of the hazards a port authority has to be prepared to deal with, and the philosophical basis for a berthing policy. In the part dealing with general instructions the objective of the safety scheme will be described. Also this part will describe the composition of the Port Safety Panel, allocation of responsibilities, passage and berthing arrangements, general safety precautions, records required, and rescue arrangements. In the part dealing with emergency procedures the role of: the Ship's Master, Harbour Authorities, Local Police, and local Health Services are discussed. As an Appendix to the paper a copy of the safety scheme that has been devised for visits of nuclear merchant ships to Southampton is given

  6. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Steger-Jensen, Kenn

    2012-01-01

    This paper proposes a framework for strategic development of a port’s collaboration with its hinterland. The framework is based on literature relevant to port development and undertakes market perspective by considering import/export data relevant for the region of interest. The series of steps...

  7. Ports and innovation

    NARCIS (Netherlands)

    Taneja, P.; Vellinga, T.; Van Schuylenburg, M.

    2012-01-01

    A volatile environment, dynamic markets, and challenges created by new environmental and social consideration demand innovative solutions. Innovation is the implementation of ideas to create value. It promises ports resilience into the future. In this paper we trace some recent successful

  8. Essays on Dry Ports

    NARCIS (Netherlands)

    G.G. Chandrakant (Gujar)

    2011-01-01

    textabstractDue to several reasons, currently the global supply chains are getting stretched further away into the hinterlands from the gateway seaports. This single fact enhances the importance of dry ports. It would not be against logic, to state that in coming times, as a result of ever-growing

  9. Port-wine stain

    Science.gov (United States)

    ... About MedlinePlus Show Search Search MedlinePlus GO GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Port-wine stain URL of this page: //medlineplus.gov/ency/ ...

  10. Development of the alternate entry port for the ATF

    International Nuclear Information System (INIS)

    Parsa, Z.

    1993-05-01

    We discussed a second entry port for the Accelerator Test Facility (ATF) injection system at Brookhaven National Laboratory, which consists of a photocathode rf gun and a straight - ahead beamline directly into the 50 MeV linac. The proposed second entry port should improve the beam quality and lower the emittance needed for FEL (Free Electron Laser), and laser - acceleration experiments. A discussion on the laser driven high brightness photoelectrons through the primary entry port (a low energy 180 degrees achromatic double bend transport line) now in operation, and a beam analysis for the proposed secondary port is also given

  11. Experimental System of Solar Adsorption Refrigeration with Concentrated Collector.

    Science.gov (United States)

    Yuan, Z X; Li, Y X; Du, C X

    2017-10-18

    To improve the performance of solar adsorption refrigeration, an experimental system with a solar concentration collector was set up and investigated. The main components of the system were the adsorbent bed, the condenser, the evaporator, the cooling sub-system, and the solar collector. In the first step of the experiment, the vapor-saturated bed was heated by the solar radiation under closed conditions, which caused the bed temperature and pressure to increase. When the bed pressure became high enough, the bed was switched to connect to the condenser, thus water vapor flowed continually from the bed to the condenser to be liquefied. Next, the bed needed to cool down after the desorption. In the solar-shielded condition, achieved by aluminum foil, the circulating water loop was opened to the bed. With the water continually circulating in the bed, the stored heat in the bed was took out and the bed pressure decreased accordingly. When the bed pressure dropped below the saturation pressure at the evaporation temperature, the valve to the evaporator was opened. A mass of water vapor rushed into the bed and was adsorbed by the zeolite material. With the massive vaporization of the water in the evaporator, the refrigeration effect was generated finally. The experimental result has revealed that both the COP (coefficient of the performance of the system) and the SCP (specific cooling power of the system) of the SAPO-34 zeolite was greater than that of the ZSM-5 zeolite, no matter whether the adsorption time was longer or shorter. The system of the SAPO-34 zeolite generated a maximum COP of 0.169.

  12. Generic Diagnostic Port Integration for the Equatorial Port Plug of ITER

    International Nuclear Information System (INIS)

    Doceul, L.; Chappuis, Ph.; Portafaix, Ch.; Guillaume, T.; Bruyere, Ch.; Walker, Ch.; Ingesson, Ch.; Ciattaglia, E.; Salasca, S.; Eric, T.

    2006-01-01

    ITER requires an extensive set of diagnostic systems to provide several key functions such as protection of the device, input to plasma control systems and evaluation of the plasma performance. Most of these diagnostics system are to be integrated in port plugs, which are water cooled stainless steel structures (approximately: 50 t, 2 m x 2 m x 4 m) inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, supporting the diagnostic equipment (within the primary vacuum, on the primary vacuum boundary and in the port interspace). CEA (Commissariat l'Energie Atomique) has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug EQ01. The specific CEA contributions were to perform the general engineering, structural and thermal analysis. These detailed analysis have highlighted some design issues which were worked out through different solutions. This paper will contain the description of the engineering activities performed such as: - The conceptual design of the EQ01 and the associated diagnostics, such as the visible and infrared optical diagnostic, - The static mechanical calculations, taking into account the electromagnetic loads occurring during fast transient plasma events, - The dynamic calculation constituted of modal and transient analysis under the same electromagnetic loads to estimate the dynamic amplification factor due to the resonance phenomenon, - The thermal assessment under the neutronic load of the water-cooled stainless steel structure, - The seismic response of the port plug inside the vacuum vessel, taking into account the ground spectra and soil conditions in the Cadarache site. (author)

  13. Experimental study on a parabolic concentrator assisted solar desalting system

    International Nuclear Information System (INIS)

    Arunkumar, T.; Denkenberger, David; Velraj, R.; Sathyamurthy, Ravishankar; Tanaka, Hiroshi; Vinothkumar, K.

    2015-01-01

    Highlights: • We optimized the augmentation of condense by enhanced desalination methodology. • Parabolic concentrator has been integrated with solar distillation systems. • We measured ambient together with solar radiation intensity. - Abstract: This paper presents a modification of parabolic concentrator (PC) – solar still with continuous water circulation using a storage tank to enhance the productivity. Four modes of operation were studied experimentally: (i) PC-solar still without top cover cooling; (ii) PC-solar still with top cover cooling, PC-solar still integrated with phase change material (PCM) without top cover cooling and PC-solar still integrated PCM with cooling. The experiments were carried out for the cooling water flow rates of 40 ml/min; 50 ml/min, 60 ml/min, 80 ml/min and 100 ml/min. Diurnal variations of water temperature (T_w), ambient air temperature (T_a), top cover temperature (T_o_c) and production rate are measured with frequent time intervals. Water cooling was not cost effective, but adding PCM was.

  14. Long-term performance potential of concentrated photovoltaic (CPV) systems

    KAUST Repository

    Burhan, Muhammad

    2017-07-17

    Owing to the diverse photovoltaic (PV) systems’ design and technology, as well as the dynamic nature of insolation data received on the aperture surfaces, the instantaneous output from a PV system fluctuates greatly. For accurate performance estimation of a large PV field, the long term performance as electrical output is a more rational approach over the conventional testing methods, such as at Standard Testing Conditions (STC) and at the Nominal Operating Cell Temperature (NOCT) available hitherto. In this paper, the long-term performances of concentrated PVs (Cassegrain reflectors and Fresnel lens) with 2-axes tracking and a variety of PV systems, namely the stationary flat-plate PV (mono-crystalline, poly-crystalline and thin-films CIS types), is presented over a period of one year for the merit comparison of system design, under the tropical weather conditions of Singapore. From the measured field performances, the total energy output of 240.2 kW h/m/year is recorded for CPV operation in Singapore, which is nearly two folds higher than the stationary PV panels.

  15. Silicon concentrator cells in a two-stage photovoltaic system with a concentration factor of 300x

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, A.

    2005-06-15

    In this work a rear contacted silicon concentrator cell was developed for an application in a two stage concentrator photovoltaic system. This system was developed at Fraunhofer ISE some years ago. The innovation of this one-axis tracked system is that it enables a high geometrical concentration of 300x in combination with a high optical efficiency (around 78%) and a large acceptance angle of {+-}23.5 all year through. For this, the system uses a parabolic mirror (40.4x) and a three dimensional second stage consisting of compound parabolic concentrators (CPCs, 7.7x). For the concentrator concept and particularly for an easy cell integration, the rear line contacted concentrator (RLCC) cells with a maximum efficiency of 25% were developed and a hybrid mounting concept for the RLCC cells is presented. The optical performance of different CPC materials was tested and analysed in this work. Finally, small modules consisting of six series interconnected RLCC cells and six CPCs were integrated into the concentrator system and tested outdoor. A system efficiency of 16.2% was reached at around 800 W/m2 direct irradiance under realistic outdoor conditions. (orig.)

  16. The Development of the Regional Sea Port Infrastructure on the Basis of Dry Port

    Directory of Open Access Journals (Sweden)

    Aleksandr Nelevich Rakhmangulov

    2016-09-01

    Full Text Available This article contributes to the solution of the relevant problem of the seaport infrastructure development for the purpose of increasing the cargo turnover in the regions of seaport location as well as to improve the quality of freight traffic on the basis of the creation of container hinterlands — dry ports. The options of dry ports as the potentially effective solution to increase the cargo turnover of existing seaports, improve the timeliness of freight transportation and overcome the environmental problems of the regions of seaport location are shown. This work analyzes the transport infrastructure of the region, the cargo turnover of major Russian sea and dry ports as well as the experience of creating dry ports in the Russian Federation and abroad. The authors propose the system of parameters for dry ports, which are recommended for the assessment of seaport infrastructure development scenarios on the stage of strategic planning. The authors have developed the approach of optimal values determination of the main parameters of dry ports by simulation modeling method. The features of construction and research of the simulation models of system “seaport — dry port” in programming software AnyLogic are considered. The results of modeling experiments with a developed simulation model are provided. This model is aimed to assess the maximum estimated capacity of the existing seaport in the conditions of the increasing irregularity of cargo traffic, and also to determine the optimum parameters of the constructed «dry port». The obtained dependencies as a result of modeling experiments prove the adequacy of the selected main parameters of dry ports for the effective evaluation of the scenarios of the strengthening of carrying and estimated capacity of existing seaports on the stage of strategic planning. The article shows that the methodology of this research can be used by the investors and public authorities as grounds for a decision on

  17. An XML-Based Knowledge Management System of Port Information for U.S. Coast Guard Cutters

    National Research Council Canada - National Science Library

    Stewart, Jeffrey

    2003-01-01

    .... The system uses XML technologies in server/client and stand alone environments. With a web browser, the user views and navigates the system's content from a downloaded file collection or from a centralized data source via a network connection...

  18. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1999

    Energy Technology Data Exchange (ETDEWEB)

    Kawasaki, Nobuo; Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru [Fujitsu Ltd., Tokyo (Japan); Ogasawara, Shinobu; Kume, Etsuo; Adachi, Masaaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Yatake, Yo-ichi [Hitachi Ltd., Tokyo (Japan)

    2001-01-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system, the SX-4 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 18 codes in fiscal 1999. These results are reported in 3 parts, i.e., the vectorization and the parallelization part on vector processors, the parallelization port on scalar processors and the porting part. In this report, we describe the porting. In this porting part, the porting of Assisted Model Building with Energy Refinement code version 5 (AMBER5), general purpose Monte Carlo codes far neutron and photon transport calculations based on continuous energy and multigroup methods (MVP/GMVP), automatic editing system for MCNP library code (autonj), neutron damage calculations for materials irradiations and neutron damage calculations for compounds code (SPECTER/SPECOMP), severe accident analysis code (MELCOR) and COolant Boiling in Rod Arrays, Two-Fluid code (COBRA-TF) on the VPP500 system and/or the AP3000 system are described. (author)

  19. 3D Spatial Information Infrastructure for the Port of Rotterdam

    NARCIS (Netherlands)

    Zlatanova, S.; Beetz, J.; Boersma, A.J.; Mulder, A.; Goos, J.

    2013-01-01

    The maintenance of the complex infrastructure and facilities of Port of Rotterdam is based on large amounts of heterogeneous information. Almost all activities of the Port require spatial information about features above- and under- ground. Current information systems are department and data

  20. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  1. Two-Port Laparoscopic Reconstructive Surgery of the Urinary Tract with Reusable Umbilical System (Hybrid Less): A Proof of Concept Study.

    Science.gov (United States)

    Angulo, Javier C; Pérez, Sergio; García-Tello, Ana; Redondo, Cristina; Meilán, Elisa; Arance, Ignacio

    2016-01-01

    We compared perioperative results and complications of reconstructive surgery of the urinary tract performed using a multichannel platform through the umbilicus and one additional 3.5-mm with a cohort of patients simultaneously treated with conventional 4-port laparoscopy. Matched-pair study comparing perioperative outcomes, postoperative visual analogue pain scale (VAPS) and morbidity of 2-port (n = 20) and 4-port (n = 10) laparoscopic reconstructive urological surgery. Preoperative and perioperative data compared included demographics, type of surgery, operative time, blood loss, decrease in serum hemoglobin, operative complications, length of stay and postoperative complications according to Clavien-Dindo classification. There was no significant difference between groups regarding age, gender, body mass index, American Society of Anesthesiologists score, type of surgery, operative time, operative complications and intraoperative or postoperative transfusion. Estimated blood loss was lower using reduced-port approach. VAPS at postoperative day one was significantly lower for 2-port approach and so was the length of stay. Patient satisfaction with the wound was higher for 2-port surgery. Differences were not observed in number and severity of postoperative complications. Urological reconstructive operations can be safely performed using the hybrid laparoendoscopic single-site umbilical approach, resulting in lower blood loss, higher patient satisfaction and lower postoperative pain, which also facilitate earlier hospital discharge, than the same reconstructive procedures performed through multiport conventional laparoscopy. © 2016 S. Karger AG, Basel.

  2. Port interface requirements

    International Nuclear Information System (INIS)

    O'Neil, R.

    1978-01-01

    In a land-based reactor programme the Administration are usually confronted with a specific design in a particular environment. Safety and Reliability criteria necessary to the designer can be specified on the basis of acceptable risk to the population. However for the successful implementation of a nuclear ship programme on a broad commercial basis it is necessary to have agreed standards of risks from ships yet to be designed and agreed standards of acceptable risks to the population at likely ports of call yet to be specified, consulted, or agreed. At first sight it would seem that this double uncertainty must either lead to unnecessarily high safety standards for the ship or unacceptably conservative standards for berth selection. The paper discusses the problem and proposes a possible solution based on the concept of a 'Standard Port' and a 'Standard Ship' and indicates the level of risk implied by such a concept

  3. Plasma D-dimer concentration in patients with systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Montagnana Martina

    2006-01-01

    Full Text Available Abstract Background Systemic sclerosis (SSc is an autoimmune disorder of the connective tissue characterized by widespread vascular lesions and fibrosis. Little is known so far on the activation of the hemostatic and fibrinolytic systems in SSc, and most preliminary evidences are discordant. Methods To verify whether SSc patients might display a prothrombotic condition, plasma D-dimer was assessed in 28 consecutive SSc patients and in 33 control subjects, matched for age, sex and environmental habit. Results and discussion When compared to healthy controls, geometric mean and 95% confidence interval (IC95% of plasma D-dimer were significantly increased in SSc patients (362 ng/mL, IC 95%: 361–363 ng/mL vs 229 ng/mL, IC95%: 228–231 ng/mL, p = 0.005. After stratifying SSc patients according to disease subset, no significant differences were observed between those with limited cutaneous pattern and controls, whereas patients with diffuse cutaneous pattern displayed substantially increased values. No correlation was found between plasma D-dimer concentration and age, sex, autoantibody pattern, serum creatinine, erythrosedimentation rate, nailfold videocapillaroscopic pattern and pulmonary involvement. Conclusion We demonstrated that SSc patients with diffuse subset are characterized by increased plasma D-dimer values, reflecting a potential activation of both the hemostatic and fibrinolytic cascades, which might finally predispose these patients to thrombotic complications.

  4. Analysis of battery behavior in small photovoltaic systems; Analise do comportamento da bateria utilizada em sistemas fotovoltaicos de pequeno porte

    Energy Technology Data Exchange (ETDEWEB)

    Fraga, Jose Renato Castro Pompeia; Cagnon, Jose Angelo [Programa de Pos-Graduacao em Agronomia - Energia na Agricultura - FCA/UNESP, Botucatu, SP (Brazil); Dept. de Engenharia Eletrica - FEB/UNESP, Bauru, SP (Brazil)], e-mails: jrfraga@feb.unesp.br, jacagnon@feb.unesp.br

    2011-07-01

    This work aimed to analyze the electric energy storage system generated from a photovoltaic system with lead-acid batteries. The increasing claim for energy in the world in addition to the need of using renewable energy sources in order to preserve the environment makes necessary the development of efficient techniques of power supply and control. Two photovoltaic systems were used in this work, a conventional one with stationary solar panel and another with automatic solar position system. The comparative analysis has allowed assessing the advantages of both systems. The following characteristics were obtained during the development of this work: charge, discharge, battery capacity, operating time rate, auto-discharge reaction (through fluctuation state), among other important information that allows an extended life to the stationary battery studied. The obtained results indicate that the battery connected to the mobile system provides 36% of additional energy compared to the fixed system. When the battery was unable to provide energy to the load, the battery connected to the mobile system consumed about 33% less energy than that one connected to the fixed system (author)

  5. Demonstration and evaluation of the 20-ton-capacity load-cell-based weighing system, Eldorado Resources, Ltd., Port Hope, Ontario, September 3-4, 1986

    International Nuclear Information System (INIS)

    Cooley, J.N.; Huxford, T.J.

    1986-01-01

    On September 3 and 4, 1986, the prototype 20-ton-capacity load-cell-based weighing system (LCBWS) developed by the US Enrichment Safeguards Program (ESP) at Martin Marietta Energy Systems, Inc., was field tested at the Eldorado Resources, Ltd., (ERL) facility in Port Hope, Ontario. The 20-ton-capacity LCBWS has been designed and fabricated for use by the International Atomic Energy Agency (IAEA) for verifying the masses of large-capacity UF 6 cylinders during IAEA safeguards inspections at UF 6 handling facilities. The purpose of the Canadian field test was to demonstrate and to evaluate with IAEA inspectorates and with UF 6 bulk handling facility operators at Eldorado the principles, procedures, and hardware associated with using the 20-ton-capacity LCBWS as a portable means for verifying the masses of 10- and 14-ton UF 6 cylinders. Session participants included representatives from the IAEA, Martin Marietta Energy Systems, Inc., Eldorado Resources, Ltd., the Atomic Energy Control Board (AECB), and the International Safeguards Project Office (ISPO) at Brookhaven National Laboratory (BNL). Appendix A presents the list of participants and their organization affiliation. The two-day field test involved a formal briefing by ESP staff, two cylinder weighing sessions, IAEA critiques of the LCBWS hardware and software, and concluding discussions on the field performance of the system. Appendix B cites the meeting agenda. Summarized in this report are (1) the technical information presented by the system developers, (2) results from the weighing sessions, and (3) observations, suggestions, and concluding statements from meeting participants

  6. PERFORMANCE ASSESSMENT IN OPERATING DRY PORTS

    Directory of Open Access Journals (Sweden)

    Ciortescu Cezar-Gabriel

    2010-12-01

    Full Text Available In this paper, an approach for recognizing and defining correct and operable performance will be presented with the purpose of evaluating the effectiveness and efficiency of processes in dry ports (inland intermodal hubs. The challenge in evaluating the possible improvements of the underlying processes lies in the special nature and the complex structure of dry ports. It is important to consider that all the processes are highly interconnected and that changes in parameters in one process also have an impact on parameters in other processes. Furthermore, the performance of dry ports, seen as the backbone of the system, has a significant impact on the overall performance of the whole transportation network.

  7. Development of the Bosaso Port Somalia

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    1988-01-01

    The first stage of the port of Bosaso will be completed within half a year's time. It offers accomodation for one general cargo/Ro-Ro vessel of 5,000 DWT plus 350 meters of quays for small cargo vessels and fishing boats. Hinterlands for handling of the goods are arranged along the quays. Areas...... for long term storage of goods and storage of oil are not yet provided. The first stage represents a significant development in the transport system of Somalia in being the most prosperous port in the northern Somalia because of its position at the terminal of the new north-south national main road and its...

  8. Operational Optimization in Port Container Terminals

    DEFF Research Database (Denmark)

    As a result of the significant increase in worldwide containerized transportation the development of efficient handling systems in marine terminals has become very important for port competitiveness. In order to optimize the productivity the total handling time for containers in the terminal must...... be minimized. An overview of the different operational problems in port container terminals is presented and an aggregated model and solution approach is shown. Next, there will be focused on the yard storage problem and a mathematical formulation and solution proposals will be presented....

  9. Polyaspartic Acid Concentration Controls the Rate of Calcium Phosphate Nanorod Formation in High Concentration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Krogstad, Daniel V. [Biosystems and; Wang, Dongbo [Biosystems and; Lin-Gibson, Sheng [Biosystems and

    2017-08-31

    Polyelectrolytes are known to greatly affect calcium phosphate (CaP) mineralization. The reaction kinetics as well as the CaP phase, morphology and aggregation state depend on the relative concentrations of the polyelectrolyte and the inorganic ions in a complex, nonlinear manner. This study examines the structural evolution and kinetics of polyaspartic acid (pAsp) directed CaP mineralization at high concentrations of polyelectrolytes, calcium, and total phosphate (19–30 mg/mL pAsp, 50–100 mM Ca2+, Ca/P = 2). Using a novel combination of characterization techniques including cryogenic transmission electron microscopy (cryo-TEM), spectrophotometry, X-ray total scattering pair distribution function analysis, and attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), it was determined that the CaP mineralization occurred over four transition steps. The steps include the formation of aggregates of pAsp stabilized CaP spherical nanoparticles (sNP), crystallization of sNP, oriented attachment of the sNP into nanorods, and further crystallization of the nanorods. The intermediate aggregate sizes and the reaction kinetics were found to be highly polymer concentration dependent while the sizes of the particles were not concentration dependent. This study demonstrates the complex role of pAsp in controlling the mechanism as well as the kinetics of CaP mineralization.

  10. Optimum Concentration Ratio Analysis Using Dynamic Thermal Model for Concentrated Photovoltaic System

    Science.gov (United States)

    2012-03-22

    Iberoamericano de Estudiantes de Ingenieria Electrica, s.l. : Cibelec, 2005. 40. Brogren, Maria. Optical Effeciency of Low-Concentrating Solar Energy...46 3.5 Particular Solution to the Transport Equation...50 3.7 Homogenous Solution the Transport Equation ..................................................... 51 3.8 Total Excess

  11. Remote Handling behind port plug in ITER

    International Nuclear Information System (INIS)

    Bede, O.; Neuberger, H.

    2006-01-01

    Different Test Blanket Modules (TBM) will be used in succession in the same equatorial ports of ITER. The remote handling operations for connection/disconnection of an interface between the port plug of the EU-HCPB-TBM and the port cell equipment are investigated with the goal to reach a quick and simple TBM exchange procedure. This paper describes the operations and systems which are required for connection of the TBM to its supply lines at this interface. The interface is located inside the free space of the port plug flange between the port plug shield and the bioshield of the port cell behind. The approach of the operation place is only available through a narrow gate in the bioshield opened temporarily during maintenance periods. This gate limits the dimensions of the whole system and its tools. The current design of the EU-HCPB-TBM foresees up to 9 supply lines which have to be connected inside the free space of one half of the port plug flange. The connection operations require positioning and adjustment of the tools for each pipe separately. Despite the strict circumstances it is still possible to find such an industrial jointed-arm robot with sufficient payload, which can penetrate into the working area. A mechanical system is necessary to move the robot from its storing place in the hot cell to the port plug on 6 m distance. Each operation requires different end-of-arm tools. The most special one is a pipe positioner tool, which can position and pull the pipe ends to each other and align the tool before welding and hold them in proper position during the welding process. Weld seams can be made by orbital welding tool. The pipe positioner tool has to provide place for welding tool. Using of inbore tool is impossible because pipes have no open ends where the tool could leave it. Orbital tool must be modified to meet requirements of remote handling because it is designed for human handling. The coolant is helium, so for eliminating the leak of helium it is

  12. Concentration and characterization of airborne particles in Tehran's subway system.

    Science.gov (United States)

    Kamani, Hosein; Hoseini, Mohammad; Seyedsalehi, Mahdi; Mahdavi, Yousef; Jaafari, Jalil; Safari, Gholam Hosein

    2014-06-01

    Particulate matter is an important air pollutant, especially in closed environments like underground subway stations. In this study, a total of 13 elements were determined from PM10 and PM2.5 samples collected at two subway stations (Imam Khomeini and Sadeghiye) in Tehran's subway system. Sampling was conducted in April to August 2011 to measure PM concentrations in platform and adjacent outdoor air of the stations. In the Imam Khomeini station, the average concentrations of PM10 and PM2.5 were 94.4 ± 26.3 and 52.3 ± 16.5 μg m(-3) in the platform and 81.8 ± 22.2 and 35 ± 17.6 μg m(-3) in the outdoor air, respectively. In the Sadeghiye station, mean concentrations of PM10 and PM2.5 were 87.6 ± 23 and 41.3 ± 20.4 μg m(-3) in the platform and 73.9 ± 17.3 and 30 ± 15 μg m(-3), in the outdoor air, respectively. The relative contribution of elemental components in each particle fraction were accounted for 43% (PM10) and 47.7% (PM2.5) in platform of Imam Khomeini station and 15.9% (PM10) and 18.5% (PM2.5) in the outdoor air of this station. Also, at the Sadeghiye station, each fraction accounted for 31.6% (PM10) and 39.8% (PM2.5) in platform and was 11.7% (PM10) and 14.3% (PM2.5) in the outdoor. At the Imam Khomeini station, Fe was the predominant element to represent 32.4 and 36 % of the total mass of PM10 and PM2.5 in the platform and 11.5 and 13.3% in the outdoor, respectively. At the Sadeghiye station, this element represented 22.7 and 29.8% of total mass of PM10 and PM2.5 in the platform and 8.7 and 10.5% in the outdoor air, respectively. Other major crustal elements were 5.8% (PM10) and 5.3% (PM2.5) in the Imam Khomeini station platform and 2.3 and 2.4% in the outdoor air, respectively. The proportion of other minor elements was significantly lower, actually less than 7% in total samples, and V was the minor concentration in total mass of PM10 and PM2.5 in both platform stations.

  13. Sewage Disposal in Port Harcourt, Nigeria.

    Science.gov (United States)

    Ayotamuno, M. J.

    1993-01-01

    This survey of the Port Harcourt, Nigeria, sewage disposal system exemplifies sewage disposal in the developing world. Results reveal that some well-constructed and maintained drains, as well as many open drains and septic tanks, expose women and children to the possibility of direct contact with parasitic organisms and threaten water resources.…

  14. Transparency in port-Hamiltonian based telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2005-01-01

    After stability, transparency is the major issue in the design of a telemanipulation system. In this paper we exploit a behavioral approach in order to provide an index for the evaluation of transparency in port-Hamiltonian based teleoperators. Furthermore we provide a transparency analysis of

  15. Transparency in Port-Hamiltonian-Based Telemanipulation

    NARCIS (Netherlands)

    Secchi, Cristian; Stramigioli, Stefano; Fantuzzi, Cesare

    After stability, transparency is the major issue in the design of a telemanipulation system. In this paper, we exploit the behavioral approach in order to provide an index for the evaluation of transparency in port-Hamiltonian-based teleoperators. Furthermore, we provide a transparency analysis of

  16. Port Hamiltonian modeling of Power Networks

    NARCIS (Netherlands)

    van Schaik, F.; van der Schaft, Abraham; Scherpen, Jacquelien M.A.; Zonetti, Daniele; Ortega, R

    2012-01-01

    In this talk a full nonlinear model for the power network in port–Hamiltonian framework is derived to study its stability properties. For this we use the modularity approach i.e., we first derive the models of individual components in power network as port-Hamiltonian systems and then we combine all

  17. Agile Port and High Speed Ship Technologies

    Science.gov (United States)

    2009-12-31

    Alternative Shipboard Powering Systems for Naval and Regulatory Review • The Evaluation and Implementation Plan for Southern California Maglev ...Ackerman". CSULB Foundation Annual Report. CSULB Foundation, Long Beach, CA. December 2005. " Maglev Technology ’Conveys’ Port Transportation Solutions...34. Newsflash. College of Engineering, California State University, Long Beach. Cover page. Spring 2006 Hanson, Kristopher. "Engineers Tout Maglev at

  18. Optimal location of dry ports in the Pan-Pearl River Delta

    Directory of Open Access Journals (Sweden)

    Wu Qitao

    2017-01-01

    Full Text Available Dry ports have become a very important part of globalization and a cornerstone in port competitiveness. Based on the analytic hierarchy process, this paper established the dry port index system to evaluate the potential location of dry ports linked to the port system in the Pearl River Delta, in a case study covering 115 cities in the Pan - Pearl River Delta. The results show that it is optimal to locate 21 dry ports in the research region, and each dry port serves different areas. There are 4 optimal transport corridors for the dry port logistic network, including Guangzhou- Kunming transport corridor, Guangzhou-Chengdu transport corridor, Guangzhou-Changsha transport corridor and Shenzhen-Nanchang transport corridor.

  19. Discrete exterior geometry approach to structure-preserving discretization of distributed-parameter port-Hamiltonian systems

    NARCIS (Netherlands)

    Seslija, Marko; van der Schaft, Arjan; Scherpen, Jacquelien M.A.

    This paper addresses the issue of structure-preserving discretization of open distributed-parameter systems with Hamiltonian dynamics. Employing the formalism of discrete exterior calculus, we introduce a simplicial Dirac structure as a discrete analogue of the Stokes-Dirac structure and demonstrate

  20. A discrete exterior approach to structure-preserving discretization of distributed-parameter port-Hamiltonian systems

    NARCIS (Netherlands)

    Seslija, Marko; Scherpen, Jacquelien M.A.; van der Schaft, Arjan

    2011-01-01

    This paper addresses the issue of structure-preserving discretization of open distributed-parameter systems with Hamiltonian dynamics. Employing the formalism of discrete exterior calculus, we introduce simplicial Dirac structures as discrete analogues of the Stokes-Dirac structure and demonstrate

  1. Handling of waste in ports

    International Nuclear Information System (INIS)

    Olson, P.H.

    1994-01-01

    The regulations governing the handling of port-generated waste are often national and/or local legislation, whereas the handling of ship-generated waste is governed by the MARPOL Convention in most parts of the world. The handling of waste consists of two main phases -collection and treatment. Waste has to be collected in every port and on board every ship, whereas generally only some wastes are treated and to a certain degree in ports and on board ships. This paper considers the different kinds of waste generated in both ports and on board ships, where and how it is generated, how it could be collected and treated. The two sources are treated together to show how some ship-generated waste may be treated in port installations primarily constructed for the treatment of the port-generated waste, making integrated use of the available treatment facilities. (author)

  2. Illumination uniformity issue explored via two-stage solar concentrator system based on Fresnel lens and compound flat concentrator

    International Nuclear Information System (INIS)

    Yeh, Naichia

    2016-01-01

    This paper illustrates details about the solar radiation distribution on the target of a two-stage solar concentrator that combines the Fresnel lens (FL) and the compound flat concentrator (CFC). The paper starts with a review of some FL development milestones such as the two-stage systems and the comparisons of flat vs. curved lenses in addition to the most noteworthy FL-based solar energy application, concentration photovoltaic (CPV). Through the review of the FL based CPV and two-stage concentrators, this study leads to the development of an algorithm to explore the spectrum distribution insight on the receiver of a two-stage (FL plus CFC) solar concentration system. It established the potential for using a correctly positioned 2nd stage reflector of right dimension to selectively redirect the desired spectrum on the target area so as to enhance the concentration flux intensity and uniformity at the same time. The study also helped to chart out the approximate locations of certain spectrum segments on the FL's target area, which is useful for exploring the spectrum control mechanism via the Fresnel lenses. - Highlights: • Map out the approximate locations of spectrum segments on FL's focal area. • Use the 2nd stage reflector to selectively reflect the desired spectrum on target. • Explore the spectrum distribution insight on FL solar concentrators' target area.

  3. Engineering activities on the ITER representative diagnostic equatorial port plug

    International Nuclear Information System (INIS)

    Meunier, L.; Doceul, L.; Salasca, S.; Martins, J.-P.; Jullien, F.; Dechelle, Christian; Bidaud, Pierre; Pilard, Vincent; Terra, Alexis; Ogea, Mathieu; Ciattaglia, Emanuela; Walker, Christopher

    2009-01-01

    Most of ITER diagnostic systems are integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum vessel ports. The port plug must provide basic functions such as neutron and gamma shielding, supporting the first wall armour (BSM), closing the vacuum vessel ports, while supporting the diagnostic equipments. ITER diagnostic port plug must resist a severe environment like high temperature due to neutron interaction with the structures and high electromechanical loading during disruptions events. CEA has contributed to the design and integration tasks in the frame of the representative equatorial port plug EQ no. 01, in particular on the engineering, structural and thermal finite element analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: -The static mechanical calculations of the top plate closure system under disruption load. -The static mechanical calculations of the BSM attachment to the port plug. These two first studies led to design changes proposals which significantly improved the behaviour of the structures but also showed that the safety margin with respect to design limits is quite low. -The design of a Diagnostic Shield Module (DSM) integrated inside the port plug and a proposition of attachment scheme, with respect to disruption loads. The manufacturing of the DSM has been taken into account, as well as diagnostic integration inside the structure and maintenance aspects. -The thermal assessment of the port plug under neutronic load during normal operation, with the optimization of the cooling system. The maximum temperature calculated in normal operation has been reduced from 900 deg. C to less than 400 deg. C in the front plate; and the cooling arrangement at the back of the port plug has been simplified without important temperature increase.

  4. Engineering activities on the ITER representative diagnostic equatorial port plug

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, L. [Association Euratom CEA, CEA/DSM/IRFM (France)], E-mail: lmeunier@cea.fr; Doceul, L.; Salasca, S.; Martins, J.-P.; Jullien, F.; Dechelle, Christian; Bidaud, Pierre; Pilard, Vincent; Terra, Alexis; Ogea, Mathieu [Association Euratom CEA, CEA/DSM/IRFM (France); Ciattaglia, Emanuela [EFDA CSU, Garching (Germany); Walker, Christopher [ITER International Organisation (France)

    2009-06-15

    Most of ITER diagnostic systems are integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum vessel ports. The port plug must provide basic functions such as neutron and gamma shielding, supporting the first wall armour (BSM), closing the vacuum vessel ports, while supporting the diagnostic equipments. ITER diagnostic port plug must resist a severe environment like high temperature due to neutron interaction with the structures and high electromechanical loading during disruptions events. CEA has contributed to the design and integration tasks in the frame of the representative equatorial port plug EQ no. 01, in particular on the engineering, structural and thermal finite element analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: -The static mechanical calculations of the top plate closure system under disruption load. -The static mechanical calculations of the BSM attachment to the port plug. These two first studies led to design changes proposals which significantly improved the behaviour of the structures but also showed that the safety margin with respect to design limits is quite low. -The design of a Diagnostic Shield Module (DSM) integrated inside the port plug and a proposition of attachment scheme, with respect to disruption loads. The manufacturing of the DSM has been taken into account, as well as diagnostic integration inside the structure and maintenance aspects. -The thermal assessment of the port plug under neutronic load during normal operation, with the optimization of the cooling system. The maximum temperature calculated in normal operation has been reduced from 900 deg. C to less than 400 deg. C in the front plate; and the cooling arrangement at the back of the port plug has been simplified without important temperature increase.

  5. A review of dry ports

    OpenAIRE

    Violeta Roso; Kent Lumsden

    2010-01-01

    The objective of this article is to present the previous research on the dry port concept and to review the world's existing dry ports, that is freight terminals that use the term ‘dry port’ in their name. Therefore, the purpose of this article is to clarify the concept by showing potential discrepancies or agreements between theory and practice. Starting from a literature review on the dry port concept, this article presents a review of existing dry ports in the world. A number of qualitativ...

  6. The Development and Clinical Use of a Beam ON-LINE PET System Mounted on a Rotating Gantry Port in Proton Therapy

    International Nuclear Information System (INIS)

    Nishio, Teiji; Miyatake, Aya; Ogino, Takashi; Nakagawa, Keiichi; Saijo, Nagahiro; Esumi, Hiroyasu

    2010-01-01

    Purpose: To verify the usefulness of our developed beam ON-LINE positron emission tomography (PET) system mounted on a rotating gantry port (BOLPs-RGp) for dose-volume delivery-guided proton therapy (DGPT). Methods and Materials: In the proton treatment room at our facility, a BOLPs-RGp was constructed so that a planar PET apparatus could be mounted with its field of view covering the iso-center of the beam irradiation system. Activity measurements were performed in 48 patients with tumors of the head and neck, liver, lungs, prostate, and brain. The position and intensity of the activity were measured using the BOLPs-RGp during the 200 s immediately after the proton irradiation. Results: The daily measured activity images acquired by the BOLPs-RGp showed the proton irradiation volume in each patient. Changes in the proton-irradiated volume were indicated by differences between a reference activity image (taken at the first treatment) and the daily activity-images. In the case of head-and-neck treatment, the activity distribution changed in the areas where partial tumor reduction was observed. In the case of liver treatment, it was observed that the washout effect in necrotic tumor cells was slower than in non-necrotic tumor cells. Conclusions: The BOLPs-RGp was developed for the DGPT. The accuracy of proton treatment was evaluated by measuring changes of daily measured activity. Information about the positron-emitting nuclei generated during proton irradiation can be used as a basis for ensuring the high accuracy of irradiation in proton treatment.

  7. Port Blair declaration pledged to establish and develop Andaman and Nicobar Ocean Biogeographic Information System - Meeting report

    Digital Repository Service at National Institute of Oceanography (India)

    Chavan, V.S.; Achuthankutty, C.T.; Nazar, A.K.A.

    to implement such an inform a tion system, and monitor the progress of ANOBIS. The task force would comprise of techn i cal and da ta - management representatives from pa r - ticipating institutions, and would ensure seamless establishment and development... Declaration pledged to establish and develop Andaman and Nicobar Ocean Biogeographic Information Sy s tem* T he Andaman and Nicobar (A&N) I s- lands are located in the Indian Ocean, in the southern reaches of the Bay of Be n gal. The Andaman Sea...

  8. Towards port sustainability through probabilistic models: Bayesian networks

    Directory of Open Access Journals (Sweden)

    B. Molina

    2018-04-01

    Full Text Available It is necessary that a manager of an infrastructure knows relations between variables. Using Bayesian networks, variables can be classified, predicted and diagnosed, being able to estimate posterior probability of the unknown ones based on known ones. The proposed methodology has generated a database with port variables, which have been classified as economic, social, environmental and institutional, as addressed in of smart ports studies made in all Spanish Port System. Network has been developed using an acyclic directed graph, which have let us know relationships in terms of parents and sons. In probabilistic terms, it can be concluded from the constructed network that the most decisive variables for port sustainability are those that are part of the institutional dimension. It has been concluded that Bayesian networks allow modeling uncertainty probabilistically even when the number of variables is high as it occurs in port planning and exploitation.

  9. Queuing theory models used for port equipment sizing

    Science.gov (United States)

    Dragu, V.; Dinu, O.; Ruscă, A.; Burciu, Ş.; Roman, E. A.

    2017-08-01

    The significant growth of volumes and distances on road transportation led to the necessity of finding solutions to increase water transportation market share together with the handling and transfer technologies within its terminals. It is widely known that the biggest times are consumed within the transport terminals (loading/unloading/transfer) and so the necessity of constantly developing handling techniques and technologies in concordance with the goods flows size so that the total waiting time of ships within ports is reduced. Port development should be achieved by harmonizing the contradictory interests of port administration and users. Port administrators aim profit increase opposite to users that want savings by increasing consumers’ surplus. The difficulty consists in the fact that the transport demand - supply equilibrium must be realised at costs and goods quantities transiting the port in order to satisfy the interests of both parties involved. This paper presents a port equipment sizing model by using queueing theory so that the sum of costs for ships waiting operations and equipment usage would be minimum. Ship operation within the port is assimilated to a mass service waiting system in which parameters are later used to determine the main costs for ships and port equipment.

  10. The Industrial and Logistics Port Complex of Açu and its impacts on the drainage system and the urban structure of the Northern- Fluminense Region

    Directory of Open Access Journals (Sweden)

    Larissa Carneiro Rangel

    2014-02-01

    Full Text Available The construction of the Industrial and Logistics Port Complex of Açu will result in an accelerated process of urbanization directly related to population growth. When it no longer supports agricultural and livestock activities to meet the port activities, the region will have its urban, hydrological and economic dynamics changed. Given the fragility of the Quaternary Coastal, geomorphology of the region, these areas have occupation problems, and are subject to constant flooding. Therefore, it is necessary to make geomorphology studies of the area study so that development is can be planned, avoiding future environmental and territorial and urban problems.

  11. 360 PORT MDA - A Strategy to Improve Port Security

    Science.gov (United States)

    2006-09-01

    Participating Agencies (After: Executive Briefing..........................27 Table 6. Designated Joint Operations Center Participants (From: SAFE...Investigations CGIP Coast Guard Intelligence Program CHOC Charleston Harbor Operations Center CIO Command Intelligence Officer CMT Combating Maritime... EXECUTIVE SUMMARY Ports are critical to our economy and national security. Key hubs in the international trade network, U.S. ports accounted for more than

  12. E-Commerce in Ports

    Directory of Open Access Journals (Sweden)

    Elen Twrdy

    2002-01-01

    Full Text Available EDI (Electronic Data Interchange and electronic businessshould be looked upon as a natural evolution in the internationaltrade and transport cycle. One of the principal reasonsfor starting to use EDI are the heaps of documents written,shifted, handled, conected, transcribed and copied for normalbusiness and administrative transactions. EDJ and in generalelectronic business would have none of the disadvantages ofpaper documents and have already brought substantial benefitsand savings to companies that implement it.Most port community systems today still do not provide forelectronic transfer of funds or for electronic interchange of invoicesand other trade documents, for instance bills of lading.Such services are specific toe-business and they are the necessarytransport-related documents.

  13. Securing a port's future through Circular Economy: Experiences from the Port of Gävle in contributing to sustainability.

    Science.gov (United States)

    Carpenter, Angela; Lozano, Rodrigo; Sammalisto, Kaisu; Astner, Linda

    2018-03-01

    Ports are an important player in the world, due to their role in global production and distributions systems. They are major intermodal transport hubs, linking the sea to the land. For all ports, a key requirement for commercial and economic viability is to retain ships using them and to remain accessible to those ships. Ports need to find approaches to help them remain open. They must ensure their continued economic viability. At the same time, they face increasing pressure to become more environmentally and socially conscious. This paper examines the approach taken by the Port of Gävle, Sweden, which used contaminated dredged materials to create new land using principles of Circular Economy. The paper demonstrates that using Circular Economy principles can be a viable way of securing a port's future and contributing to its sustainability, and that of the city/region where it operates. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. The Immunology Database and Analysis Portal (ImmPort)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The ImmPort system serves as a long-term, sustainable archive of immunology research data generated by investigators mainly funded through the NIAID/DAIT. The core...

  15. Climate change considerations for the Port Hope area initiative

    International Nuclear Information System (INIS)

    Kirklady, J.; Morassutti, M.; Tamm, J.; Coutts, P.; Chambers, D.

    2006-01-01

    The Port Hope Area Initiative (PHAI) is a community-based program intended to develop a safe and long-term (approximately 500 years) solution for the management of historic low-level radioactive waste (LLRW) that has been present in the Port Hope area for many years. The PHAI undertakings involve the construction and management of two Long-Term Low-Level Radioactive Waste Management Facilities (referred to as the LTWMFs) in Port Hope and in Port Granby. These undertakings are currently undergoing detailed examination through the Environmental Screening process under the Canadian Environmental Assessment Act. The purpose of the study described in this paper was to provide information necessary to satisfy the requirements of the Scope of Environmental Assessment for the Port Hope and Port Granby Projects. In particular, the purpose of the study was to satisfy the requirements to evaluate greenhouse gas (GHG) emissions from the proposed PHAI initiatives and to evaluate the potential effect of climate change parameters on the two Projects. The Port Hope and Port Granby Projects will contribute to Ontario's GHG emission inventory due to vehicle exhaust from excavation equipment and haul trucks during the construction phase of the LTWMFs. The construction phase of the Projects is of relatively short duration, and the contribution of GHGs from each Project was determined to be insignificant compared to Ontario's GHG emissions from the Construction and Transportations sectors. The proposed project elements associated with the Port Hope and Port Granby Projects were each evaluated with respect to potential sensitivities to future change in climate parameters. Considering the potential changes to climate, a screening analysis of each element of the LTWMFs was undertaken. Because it is considered likely that the current design level storms will be exceeded within the next 500 years, it was determined that the storm water management system was potentially sensitive to changes

  16. Container Traffic In European Ports

    Directory of Open Access Journals (Sweden)

    Elen Twrdy

    2004-03-01

    Full Text Available Over the last fifteen years the European transport markethas witnessed a growth of container traffic which today reachesapproximately 50 million TEU per year. From 1997 to 2002,container traffic in the northern European ports increased from14 to 20.6 million TEU per year, in the ports of the westernMedite"anean from 6 to 10 million TEU per year, and in thenorthern Adriatic ports from 0. 69 to 0. 74 million TEU per year.The ports of the northern Adriatic are located in three states(Slovenia, Croatia and Italy with different statuses in relationto the common European market. In addition, different developmentlevels of these states are reflected in different levels ofinternational commercial exchange, the development of the existinginfrastructure and plans for the construction of new infrastructures.However, all three countries share a common goaltoincrease their competitiveness in comparison with the westemEuropean ports.

  17. Principles of subcutaneous port placement.

    Science.gov (United States)

    Gonda, Shaun J; Li, Ruizong

    2011-12-01

    The introduction of totally implantable subcutaneous devices in the early 1980s provided patients with secure, reliable venous access and also gave them the ability to move more freely and have a more normal lifestyle with these devices in place. The most common totally implantable device used today is the subcutaneous port. These ports consist of an injection port connected to a catheter. Ports provide a number of advantages compared with other venous catheters; the most important is the reduced risk of infection. These devices have significantly lower rates of infection than nontunneled and tunneled catheters. Additional advantages include less frequent irrigation and minimal home care, and they are less prone to environmental or cutaneous contamination when not being accessed. This article will focus on the placement of these ports. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Analyzing a low NO[sub x] concentric combustion system

    Energy Technology Data Exchange (ETDEWEB)

    Kotler, V.R.; Eremeev, A.V.

    1992-05-01

    Discusses concentric combustion technology developed by Combustion Engineering, Inc. (USA) to reduce NO[sub x] emissions from pulverized coal-fired boilers. The major innovation consists in arranging existing independent secondary air burners into three pairs of concentric combustion burners. Using high-deflection angle concentric combustion burners, higher oxygen concentration near the boiler walls, reduced erosion and lower probability of slag deposition on the heat shield are achieved. The technology was tested at the 165 MW Valmont power plant and 350 MW Cherokee power plant. Reduction of 55.7% (to 0.294 kg/GJ) in NO[sub x] emissions with a boiler efficiency of 86.35% was achieved. Highest NO[sub x] reduction efficiency was observed at full load (highest tertiary air supply). Burner design, performance, relations of NO[sub x] emissions and tertiary air blast as well as fuel entrainment prior to and after upgrading are given. Methods of reducing slag deposition in boilers are considered. 2 refs.

  19. Single port laparoscopic surgery

    DEFF Research Database (Denmark)

    Springborg, Henrik; Istre, Olav

    2012-01-01

    LESS, or laparo-endoscopic single site surgery, is a promising new method in minimally invasive surgery. An increasing number of surgical procedures are being performed using this technique, however, its large-scale adoption awaits results of prospective randomized controlled studies confirming...... potential benefits. Theoretically, cosmetic outcomes, postoperative pain and complication rates could be improved with use of single site surgery. This study describes introduction of the method in a private hospital in Denmark, in which 40 patients have been treated for benign gynecologic conditions....... Although the operations described are the first of their kind reported in Denmark, favorable operating times and very low complication rates are seen. It is the authors' opinion that in addition to being feasible for hysterectomy, single port laparoscopy may become the preferred method for many simple...

  20. The HomePort System

    DEFF Research Database (Denmark)

    Brønsted, Jeppe Rørbæk; Skou, Arne Joachim; Madsen, Per Printz

    2010-01-01

    Residential gateways for home automation are prerequisites to obtain optimal exploitation of energy resources, and they also have the potential to provide a unified operation of various home devices and appliances. Although a number of protocol standards have been proposed, the number...

  1. Glove port retrofit assembly and method of replacing components

    Science.gov (United States)

    Giesen, Isaac M; Cournoyer, Michael E; Rael, David G

    2014-11-18

    What is disclosed is a system for retrofitting a sealed enclosure for performing work therein having an outer enclosure assembly configured to be clamped to the outer annular face of a port ring and form a sealed engagement with the outer annular surface of the port ring, a change assembly having an inner ring and an access element wherein the inner ring has a first annular cylinder body that is sized to be slidably received by the port ring and the access element is configured to be sealably and slidably positioned within the first annular cylinder body of the inner ring.

  2. Model of decision for the management of technology and risk in a port community

    Directory of Open Access Journals (Sweden)

    Claudia Durán

    2018-10-01

    Full Text Available Strategic management in a port system is complex since the Port Community has to coordinate actions and generate synergy among all the private actors that integrate the export and import logistics chains, trade associations and trade unions. Based on the opinion of the port experts and the analytical network process (ANP, the research identifies the relevant criteria for strategic, business and operational decision-making in the Port Community, in the technological and risk contexts. With the criteria found and considering the strategic alignment that is required, management indicators are constructed. Based on a generic model, a new strategic conceptual model (PORTGD of ANP for decision management is designed for the Port Community, a cause and effect analysis is carried out and a sensitization study is performed on the nodes. The discussion of the results and conclusions highlights the importance of technological investment, control of port security and good practices for the port system investigated.

  3. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1998

    International Nuclear Information System (INIS)

    Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru; Kawasaki, Nobuo; Kume, Etsuo; Adachi, Masaaki; Ogasawara, Shinobu

    2000-03-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 12 codes in fiscal 1998. These results are reported in 3 parts, i.e., the vectorization and parallelization on vector processors part, the parallelization on scalar processors part and the porting part. In this report, we describe the porting. In this porting part, the porting of Monte Carlo N-Particle Transport code MCNP4B2 and Reactor Safety Analysis code RELAP5 on the AP3000 are described. In the vectorization and parallelization on vector processors part, the vectorization of General Tokamak Circuit Simulation Program code GTCSP, the vectorization and parallelization of Molecular Dynamics Ntv Simulation code MSP2, Eddy Current Analysis code EDDYCAL, Thermal Analysis Code for Test of Passive Cooling System by HENDEL T2 code THANPACST2 and MHD Equilibrium code SELENEJ on the VPP500 are described. In the parallelization on scalar processors part, the parallelization of Monte Carlo N-Particle Transport code MCNP4B2, Plasma Hydrodynamics code using Cubic Interpolated propagation Method PHCIP and Vectorized Monte Carlo code (continuous energy model/multi-group model) MVP/GMVP on the Paragon are described. (author)

  4. Characterization of the near-source population around five candidate ports on the Eastern Seaboard and Gulf Coast using a multi-modal freight transport perspective

    Science.gov (United States)

    Many ports are currently preparing for increased freight traffic, which may result in elevated local air pollution in areas near the port and freight transportation corridors. In this study, a geographical information system (GIS) analysis of areas surrounding five portsPort o...

  5. Final design of ITER port plug test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cerisier, Thierry, E-mail: thierry.cerisier@yahoo.fr [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Levesy, Bruno [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Romannikov, Alexander [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation); Rumyantsev, Yuri [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Cordier, Jean-Jacques; Dammann, Alexis [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Minakov, Victor; Rosales, Natalya; Mitrofanova, Elena [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Portone, Sergey; Mironova, Ekaterina [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation)

    2016-11-01

    Highlights: • We introduce the port plug test facility (purpose and status of the design). • We present the PPTF sub-systems. • We present the environmental and functional tests. • We present the occupational and nuclear safety functions. • We conclude on the achievements and next steps. - Abstract: To achieve the overall ITER machine availability target, the availability of diagnostics and heating port plugs shall be as high as 99.5%. To fulfill this requirement, it is mandatory to test the port plugs at operating temperature before installation on the machine and after refurbishment. The ITER port plug test facility (PPTF) is composed of several test stands that can be used to test the port plugs whereas at the end of manufacturing (in a non-nuclear environment), or after refurbishment in the ITER hot cell facility. The PPTF provides the possibility to perform environmental (leak tightness, vacuum and thermo-hydraulic performances) and functional tests (radio frequency acceptance tests, behavior of the plugs’ steering mechanism and calibration of diagnostics) on upper and equatorial port plugs. The final design of the port plug test facility is described. The configuration of the standalone test stands and the integration in the hot cell facility are presented.

  6. Building integration of concentrating solar systems for heating applications

    International Nuclear Information System (INIS)

    Tsoutsou, Sapfo; Infante Ferreira, Carlos; Krieg, Jan; Ezzahiri, Mohamed

    2014-01-01

    A new solar collection system integrated on the façade of a building is investigated for Dutch climate conditions. The solar collection system includes a solar façade, a receiver tube and 10 Fresnel lenses. The Fresnel lenses Fresnel lenses considered were linear, non-imaging, line – focused with a system tracking the position of the sun that ensures vertical incidence of the direct solar radiation on the lenses. For the heating system a double-effect absorption heat pump, which requires high temperature of the heating fluid, was used, working with water and lithium-bromide as refrigerant and solution respectively. The Fresnel lens system is connected with the absorption heat pump through a thermal energy storage tank which accumulates the heat from the Fresnel lens system to provide it to the high pressure generator of the absorption heat pump. - Highlights: • The integration of Fresnel lenses in solar thermal building façades is investigated. • Using building integrated Fresnel lenses, 43% heating energy can be saved. • Energy savings in Mediterranean countries are significantly larger. • The absorption heat pump could make great contribution to energy savings for Dutch climate conditions

  7. Comparison of endoscope- versus microscope-assisted resection of deep-seated intracranial lesions using a minimally invasive port retractor system.

    Science.gov (United States)

    Hong, Christopher S; Prevedello, Daniel M; Elder, J Bradley

    2016-03-01

    Tubular brain retractors may improve access to deep-seated brain lesions while potentially reducing the risks of collateral neurological injury associated with standard microsurgical approaches. Here, microscope-assisted resection of lesions using tubular retractors is assessed to determine if it is superior to endoscope-assisted surgery due to the technological advancements associated with modern tubular ports and surgical microscopes. Following institutional approval of the tubular port, data obtained from the initial 20 patients to undergo transportal resection of deep-seated brain lesions were analyzed in this study. The pathological entities of the resected tissues included metastatic tumors (8 patients), glioma (7), meningioma (1), neurocytoma (1), radiation necrosis (1), primitive neuroectodermal tumor (1), and hemangioblastoma (1). Surgery incorporated endoscopic (5 patients) or microscopic (15) assistance. The locations included the basal ganglia (11 patients), cerebellum (4), frontal lobe (2), temporal lobe (2), and parietal lobe (1). Cases were reviewed for neurological outcomes, extent of resection (EOR), and complications. Technical data for the port, surgical microscope, and endoscope were analyzed. EOR was considered total in 14 (70%), near total (> 95%) in 4 (20%), and subtotal (microscope rather than the endoscope due to a wider and 3D field of view. Improved microscope optics and tubular retractor design allows for binocular vision with improved lighting for the resection of deep-seated brain lesions.

  8. Dynamics of soluble and inert pollutant concentrations in linear and deterministic systems with time varying parameters

    International Nuclear Information System (INIS)

    Meltzer, M.

    1977-04-01

    The tracer theory in steady and non-steady systems is presented. The unsteady system was applied in the study of the concentration dynamics of the National Water Carrier in Israel. A method that uses Bromine 82 for the investigation of the transfer time distribution and of the dynamics of inert matter concentration in the system is desribed. (B.G.)

  9. Two-port robotic hysterectomy: a novel approach.

    Science.gov (United States)

    Moawad, Gaby N; Tyan, Paul; Khalil, Elias D Abi

    2018-03-24

    The objective of the study was to demonstrate a novel technique for two-port robotic hysterectomy with a particular focus on the challenging portions of the procedure. The study is designed as a technical video, showing step-by-step a two-port robotic hysterectomy approach (Canadian Task Force classification level III). IRB approval was not required for this study. The benefits of minimally invasive surgery for gynecological pathology have been clearly documented in multiple studies. Patients had fewer medical and surgical complications postoperatively, better cosmesis and quality of life. Most gynecological surgeons require 3-5 ports for the standard gynecological procedure. Even though the minimally invasive multiport system provides an excellent safety profile, multiple incisions are associated with a greater risk for morbidity including infection, pain, and hernia. In the past decade, various new methods have emerged to minimize the number of ports used in gynecological surgery. The interventions employed were a two-port robotic hysterectomy, using a camera port plus one robotic arm, with a focus on salpingectomy and cuff closure. We describe a transvaginal and a transabdominal approach for salpingectomy and a novel method for cuff closure. The transvaginal and transabdominal techniques for salpingectomy for two-port robotic-assisted hysterectomy provide excellent tension and exposure for a safe procedure without the need for an extra port. We also describe a transvaginal technique to place the vaginal cuff on tension during closure. With the necessary set of skills on a carefully chosen patient, two-port robotic-assisted total laparoscopic hysterectomy is a feasible procedure.

  10. Research on the Logistics Supply Chain in Port Logistics Transportation

    OpenAIRE

    Wang Yan-liang

    2013-01-01

    The aim of this study is to improve and increase the logistics system effectiveness and to solve the problem of optimal movement of different flows. Logistics transport carrying the world on material resources transfer exchange important mission and economic development and our lives are closely linked, logistics chain logistics transport occupies an important position and in the e logistics chain in port logistics has play a decisive role. For many coastal countries port logistics is the eco...

  11. The concentration gradient flow battery as electricity storage system

    NARCIS (Netherlands)

    Egmond, Van W.J.; Saakes, M.; Porada, S.; Meuwissen, T.; Buisman, C.J.N.; Hamelers, H.V.M.

    2016-01-01

    Unlike traditional fossil fuel plants, the wind and the sun provide power only when the renewable resource is available. To accommodate large scale use of renewable energy sources for efficient power production and utilization, energy storage systems are necessary. Here, we introduce a scalable

  12. Quantification of Melanoidin Concentration in Sugar-Casein Systems

    NARCIS (Netherlands)

    Brands, C.M.J.; Wedzicha, B.L.; Boekel, van M.A.J.S.

    2002-01-01

    Melanoidins are the final, brown, high molecular weight products of the Maillard reaction. The aim of the present study was to determine the average molar extinction coefficients of melanoidins formed in heated glucose-casein and fructose-casein systems. The value of the extinction coefficient can

  13. Developing the port of Belawan as a modern and international port

    Science.gov (United States)

    Many, N.

    2018-03-01

    This study discusses the processes of government to pass the port development plan in Indonesia with the Port of Belawan and its port expansion as the study case. The study uses a descriptive approach by reviewing and analyzing some of relevant literature as the sources. It also reviews and examines the port development theoretical concepts and models giving attention to the international hub port models resulted from the previous studies. The international hub port aspects assessed to be further applied and compared to the actual situation of the Port of Belawan. This process draws the conclusion on which concept and model the port classified, followed by some recommendations concerning the necessary actions to be taken. The results show that: (1) The port planning regulated in port master plan is the guideline and foundation to implement the port development; (2) Spatial and zoning plan regulations are very important in the preparation, planning, and implementation of port development; (3) It has not provided the necessary facilities and criteria of the global hub port model has not been met completely. The port is strategic to be completely developed as the regional hub port to compete with the major ports of neighboring countries. Eventually, this study requires further analysis to examine the economic feasibility of the Port of Belawan in more comprehensive way functioning as an international hub port along with the ongoing development of Kuala Tanjung Port to achieve its ultimate objectives, among other things, the port effectiveness, efficiency, and competitiveness.

  14. Economic Contribution of Regional Feeder Ports to The Local Economy In Indonesia

    Directory of Open Access Journals (Sweden)

    Ibnu Syabri

    2017-07-01

    Full Text Available Indonesia regional feeder ports’ main function is to serve marine transport activities between regency/city in a province in limited quantities. The intention of the government to make marine transportation as the backbone of national logistic transportation system puts these ports to an important position, as suppliers for the main and/or collector ports and as goods distribution centers for the region from the bigger ports. Not only as a provider of accessibility between regions, regional feeder ports should be seen as an investation to boost regional economy. This study aims to explain the influences of regional feeder ports on regency/city economy, based on the port types: (1 cargo ports, and (2 cargo & passengers ports. Results showed that both types of ports have positive influences on the regency/city economy, although it is not related to region’s economic base sector. Cargo ports which are mainly located on west area of Indonesia, supports the region’s economy more than cargo & passenger ports which are mainly located on the east.

  15. Port Environmental Management Challenges, Possibilities and Innovations in a Globalization Context

    Directory of Open Access Journals (Sweden)

    Dione Iara Silveira Kitzmann

    2014-12-01

    Full Text Available Port activity within an overall port environmental system encompassing the whole coastal area in which ports are situated constitutes an important analytical tool. The considerable potential for controlling and influencing activities that occur in the same geographical area means that ports generate significant positive and negative environmental impacts. This importance and the significant expansion of the Brazilian port sector in recent years gave rise to the need for Port Environmental Management (GAP based on internationally accepted environmental standards. This article discusses nested elements in the concept of port environmental management which take into account new realities of Brazilian ports as well as international standards concerning environmentally appropriate measures for the sector. New international technical proposals are discussed with regard to Brazilian port policy and the port of Rio Grande (Rio Grande do Sul State is used as a case study, highlighting its structures and the model of port environmental management being implemented.

  16. Current situation and countermeasures of port logistics park information construction

    Directory of Open Access Journals (Sweden)

    Zhen Liu

    2013-03-01

    Full Text Available Purpose: Improve work efficiency of logistics park department, and drive the economy of the park and its surrounding areas. Design/methodology/approach: Analyze the information development situation and existent questions of current national logistics park, and design proper scheme to meet the demand of port logistics park. Findings: Proposed an information construction implementation plan using technology of the Internet of things which can be applied to port logistics park. Designed a scheme for the park information construction and explained the system's implementation strategy and implementation steps. Practical implications: The proposed construction program is particularly suitable for the northwest port logistics parks in China, and also has reference function to other logistics park construction. Originality/value: Group the information construction of the logistics park into four levels, three types of users, and two requirements. The scheme is innovative and comprehensive, which can ensure the development of port logistics park.

  17. Spatial glocalization in Asia-Pacific hub port cities : A comparison of Hong Kong and Singapore

    NARCIS (Netherlands)

    S.-W. Lee (Sung-Woo); C. Ducruet (César)

    2009-01-01

    textabstractPort competition at both the regional and global scales results in port concentration and deconcentration, respectively. Whereas a number of recent studies interpret such phenomena as the effects of global forces such as containerization, few researchers have investigated local forces,

  18. Feasibility and parametric evaluation of hybrid concentrated photovoltaic-thermoelectric system

    DEFF Research Database (Denmark)

    Rezaniakolaei, Alireza; Rosendahl, Lasse Aistrup

    2017-01-01

    Concentrated photovoltaic (CPV) system integrated with thermoelectric generators (TEGs) is a novel technology that has potential to offer high efficient system. In this study, a thermally coupled model of concentrated photovoltaic-thermoelctric (CPV/TEG) system is established to investigate...... feasibility of the hybrid system over wide range of solar concentrations and different types of heat sinks. The model takes into account critical design parameters in the CPV and the TEG module. The results of this study show that for thermoelectric materials with ZT ≈ 1, the CPV/TEG system is more efficient...

  19. Laser-Based Optical System for Reactive Radical Concentration Measurements in Plasmas and Flames

    National Research Council Canada - National Science Library

    Fridman, Alexander

    2006-01-01

    Defense University Research Instrumentation Program (DURIP) funding was used to assemble a multi-purpose optical diagnostic system for in-situ radical concentration measurements in plasma and combustion systems...

  20. Vortex sound in bass-reflex ports of loudspeakers : part II. a method to estimate the point of separation

    NARCIS (Netherlands)

    Roozen, N.B.; Bockholts, M.; van Eck, P.; Hirschberg, A.

    1998-01-01

    In part I of this paper, the vortex shedding that may occur in a bass-reflex port of a loudspeaker system was discussed. At the Helmholtz frequency of the bass-reflex port, air is pumped in and out at rather high velocities, vortex shedding occurs at the end of the port, and blowing sounds are

  1. Case Studies: Improving Environmental Performance and Economic Prosperity at Ports and in Near-Port Communities

    Science.gov (United States)

    Case Study links for improving environmental performance and economic prosperity at ports and in near-port communities. Case studies on equipment upgrades, jobs and benefits, land use and transportation, port-community engagement, and citizen science.

  2. Test Port for Fiber-Optic-Coupled Laser Altimeter

    Science.gov (United States)

    Ramos Izquierdo, Luis; Scott, V. Stanley; Rinis, Haris; Cavanaugh, John

    2011-01-01

    A test port designed as part of a fiber optic coupled laser altimeter receiver optical system allows for the back-illumination of the optical system for alignment verification, as well as illumination of the detector(s) for testing the receiver electronics and signal-processing algorithms. Measuring the optical alignment of a laser altimeter instrument is difficult after the instrument is fully assembled. The addition of a test port in the receiver aft-optics allows for the back-illumination of the receiver system such that its focal setting and boresight alignment can be easily verified. For a multiple-detector receiver system, the addition of the aft-optics test port offers the added advantage of being able to simultaneously test all the detectors with different signals that simulate the expected operational conditions. On a laser altimeter instrument (see figure), the aft-optics couple the light from the receiver telescope to the receiver detector(s). Incorporating a beam splitter in the aft-optics design allows for the addition of a test port to back-illuminate the receiver telescope and/or detectors. The aft-optics layout resembles a T with the detector on one leg, the receiver telescope input port on the second leg, and the test port on the third leg. The use of a custom beam splitter with 99-percent reflection, 1-percent transmission, and a mirrored roof can send the test port light to the receiver telescope leg as well as the detector leg, without unduly sacrificing the signal from the receiver telescope to the detector. The ability to test the receiver system alignment, as well as multiple detectors with different signals without the need to disassemble the instrument or connect and reconnect components, is a great advantage to the aft-optics test port. Another benefit is that the receiver telescope aperture is fully back-illuminated by the test port so the receiver telescope focal setting vs. pressure and or temperature can be accurately measured (as

  3. Immune and stress mediators in response to bilateral adnexectomy: comparison of single-port access and conventional laparoscopy in a porcine model.

    Science.gov (United States)

    Gracia, Meritxell; Sisó, Cristian; Martínez-Zamora, M Àngels; Sarmiento, Laura; Lozano, Francisco; Arias, Maria Teresa; Beltrán, Joan; Balasch, Juan; Carmona, Francisco

    2014-01-01

    To evaluate systemic markers of immune and stress responses after bilateral adnexectomy performed using 2 different laparoscopic techniques in pigs. Prospective comparative study (Canadian Task Force classification II-2). University teaching hospital, research hospital, and tertiary care center. Twenty female Yorkshire pigs undergoing laparoscopic surgery. Animals underwent bilateral salpingo-oophorectomy (ovary and fallopian tube extraction), performed via conventional laparoscopy (n = 10) or the single-port access approach (n = 10). Injury provokes an acute-phase response, primarily produced by cytokines. The inflammatory response has been well described for major surgery and for conventional laparoscopy; however, little information is currently available for single-port laparoscopy, and none in the gynecologic field. This is the first study to compare serum cytokine interleukin 6 (IL-6) and tumor necrosis factor alpha (TNF-α) concentrations at baseline and in the early postoperative period (2, 4, and 20 hours) after bilateral salpingo-oophorectomy performed via conventional laparoscopy (n = 10) or single-port access (n = 10) in a porcine model. The stress response was measured using glucose and cortisol concentrations and the animals' response to surgery via a 6-category observation-based behavior test. Both IL-6 and TNF-α concentrations peaked at 4 hours after surgery, and were significantly lower in the single-port access group (p = .02) than in the conventional laparoscopy group (p = .02). In addition, in the single-port access group, concentrations of stress markers were slightly lower at all intervals recorded and were statistically significant at 2 hours after the operation for glucose concentration (mean [SD], 164.50 [26.73] mg/dL for conventional laparoscopy vs 86.50 [17.93] mg/dL for single-port access; p = .02). Evidence of improved inflammatory and stress responses was recorded in the minimally invasive single-port group. More clinical

  4. Optimization research on the concentration field of NO in selective catalytic reduction flue gas denitration system

    Science.gov (United States)

    Zheng, Qingyu; Zhang, Guoqiang; Che, Kai; Shao, Shikuan; Li, Yanfei

    2017-08-01

    Taking 660 MW generator unit denitration system as a study object, an optimization and adjustment method shall be designed to control ammonia slip, i.e. adjust ammonia injection system based on NO concentration distribution at inlet/outlet of the denitration system to make the injected ammonia distribute evenly. The results shows that, this method can effectively improve NO concentration distribution at outlet of the denitration system and decrease ammonia injection amount and ammonia slip concentration. Reduce adverse impact of SCR denitration process on the air preheater to realize safe production by guaranteeing that NO discharge shall reach the standard.

  5. U.S. port commerce in radioactive materials

    International Nuclear Information System (INIS)

    Marti, B.E.

    1987-01-01

    Much attention has focused on the movement of radioactive materials over land transport systems. On the other hand, maritime flow and associated throughput studies of such substances have been neglected. Although several peaks and troughs are evident between 1972 and 1981, radioactive tonnage moving through U.S. port facilities steadily increasing. In the ten-year period assessed, total radioactive materials handled at U.S. ports expanded by over 19,000 tons, which amounts to almost a 173 percent growth rate. The purpose of this exploratory research is threefold. First, it identifies all U.S. ports which were involved in loading or discharging radioactive materials. The major goal of the identification process is to broaden public awareness of these types of movement. Second, it classifies U.S. seaports based on the magnitude of radioactive tonnage handled. The function of the classification is to impose some order on the varied data, while at the same time categorizing large, medium, and small facilities. Finally, it seeks to verify whether or not a long term trend exists. The objective of the verification process is to ascertain if the distribution of radioactive materials handled at individual ports has remained constant. Port safety and contingency planning are clearly within the purview of coastal zone management. The results of this preliminary research should form a foundation for future studies which compare and evaluate local, state, and federal regulatory policy pertaining to port operations involving radioactive materials, including waste

  6. Cooperation Performance Evaluation between Seaport and Dry Port; Case of Qingdao Port and Xi'an Port

    Directory of Open Access Journals (Sweden)

    Jian Li

    2014-12-01

    Full Text Available Along with the drastic competition among ports, the strive for the vast economic hinterland and the supply of goods have become strategic problems for port operators. At the same time, port enterprises are paying more and more attention to the construction of dry ports. This article establishes the port cooperation performance evaluation index based on the balanced score card method and uses the grey relational degree method to evaluate the cooperation performance between seaports and dry ports. Finally using Qingdao port and Xi'an port as an example, and Zhengzhou port and Lanzhou port as benchmarks, the application of this evaluation method is introduced in detail. The conclusion reveals that cooperation between Qingdao port and Xi'an port has deficiencies in customer satisfaction, financial cooperation and non-market tools. Alongside this, the author proposes related issues about information management in the supply chain, competition position and the scope of hinterland. This article, combined with the related theory of supply chain and performance evaluation, puts forward a set of relatively complete cooperation performance evaluations between seaports and dry ports, which provide scientific theory support for better cooperation.

  7. Feasibility and parametric evaluation of hybrid concentrated photovoltaic-thermoelectric system

    DEFF Research Database (Denmark)

    Rezaniakolaei, Alireza; Rosendahl, Lasse Aistrup

    2017-01-01

    Concentrated photovoltaic (CPV) system integrated with thermoelectric generators (TEGs) is a novel technology that has potential to offer high efficient system. In this study, a thermally coupled model of concentrated photovoltaic-thermoelctric (CPV/TEG) system is established to investigate...... than CPV-only system. The results indicate that contribution of the TEG in power generation enhances at high sun concentrations. Depending to critical design parameters of the CPV and the TEG, there are optimal values for heat transfer coefficient in the heat sink that offer minimum energy cost....... feasibility of the hybrid system over wide range of solar concentrations and different types of heat sinks. The model takes into account critical design parameters in the CPV and the TEG module. The results of this study show that for thermoelectric materials with ZT ≈ 1, the CPV/TEG system is more efficient...

  8. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    Directory of Open Access Journals (Sweden)

    Qing-Hui WANG

    2014-02-01

    Full Text Available This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or concentration, the proposed detection system with lower cost and higher accuracy can be applied in the occasion which needs simultaneous monitoring of gas concentration and flow rate.

  9. Leaching of a copper flotation concentrate with ammonium persulfate in an autoclave system

    Science.gov (United States)

    Deniz Turan, M.; Soner Altundoğan, H.

    2014-09-01

    The leaching behavior of a copper flotation concentrate was investigated using ammonium persulfate (APS) in an autoclave system. The decomposition products of APS, active oxygen, and acidic medium were used to extract metals from the concentrate. Leaching experiments were performed to compare the availability of APS as an oxidizing agent for leaching of the concentrate under atmospheric conditions and in an autoclave system. Leaching temperature and APS concentration were found to be important parameters in both leaching systems. Atmospheric leaching studies showed that the metal extractions increased with the increase in APS concentration and temperature (up to 333 K). A similar tendency was determined in the autoclave studies up to 423 K. It was also determined that the metal extractions decreased at temperatures above 423 K due to the passivation of the particle surface by molten elemental sulfur. The results showed that higher copper extractions could be achieved using an autoclave system.

  10. Support structure concept for integration of ITER diagnostics in the port cell

    Energy Technology Data Exchange (ETDEWEB)

    Udintsev, V.S., E-mail: victor.udintsev@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Portalès, M.; Giacomin, T.; Darcourt, O.; Direz, M.-F.; Martins, J.P.; Penot, C.; Arumugam, A.P.; Drevon, J.-M.; Friconneau, J.P.; Levesy, B.; Maquet, P.; Patel, K.M.; Pitcher, C.S. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Popova, E. [Russian Federation Domestic Agency, Moscow (Russian Federation); Proust, M. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Ronden, D.M.S. [DIFFER, Nieuwegein (Netherlands); Walker, C.I.; Walsh, M.J.; Watts, C. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France)

    2013-10-15

    Highlights: ► An interspace support structure to support the diagnostic systems from the back of the upper and equatorial port plugs to the biological shield plug. ► Port cell support structures are foreseen to handle the equipment in the port cell. ► Both ISS and PCSS will be supported by means of RH rail system. ► The structures will be positioned with a certain tolerance. ► The proposed concepts are found to fulfil the needs for support of the diagnostics in ITER. -- Abstract: Development of the diagnostics for ITER tokamak, which is presently under construction by several international partners at Cadarache in France, is a major challenge because of severe environment, strict engineering requirements, and the need for high reliability in the measurements. The diagnostic systems in the upper, equatorial and lower port cells on ITER are designed to be integrated within the interspace and port cell support structures. These structures are interfacing with remote handling rail system for the cask operations, thus facilitating the removal and installation of the diagnostics in the port and hence minimizing time for working close to the tokamak. In this paper, the challenges associated with the integration of the diagnostics in the port interspace and port cell, as well as their solutions will be addressed and presented. The interspace and the port cell support structures, as well as their interfaces with the biological shield, will be discussed.

  11. Interface Circuit For Printer Port

    Science.gov (United States)

    Tucker, Jerry H.; Yadlowsky, Ann B.

    1991-01-01

    Electronic circuit, called printer-port interface circuit (PPI) developed to overcome certain disadvantages of previous methods for connecting IBM PC or PC-compatible computer to other equipment. Has both reading and writing modes of operation. Very simple, requiring only six integrated circuits. Provides for moderately fast rates of transfer of data and uses existing unmodified circuit card in IBM PC. When used with appropriate software, circuit converts printer port on IBM PC, XT, AT, or compatible personal computer to general purpose, 8-bit-data, 16-bit address bus that connects to multitude of devices.

  12. Effectively reducing emissions from ports

    Energy Technology Data Exchange (ETDEWEB)

    Fazlagic, Ismir; Martelin, Marcus; Skinner, Ryan

    2010-09-15

    Commercial ships calling at more and more ports worldwide can now turn off their diesel engines and tap into cleaner energy sources provided by electrical connections from shore. The technology to make this possible has been in place for over a decade. With a global technology standard due to be ratified by three technical bodies in 2010, high-voltage shore connections will soon get much more attention. Environmentally-minded ports, governments and shipowners are all tuning in to the benefits of supplying electricity to ships at berth. ABB presents the challenge, the technical solution and the business case for all parties involved.

  13. System for measuring of air concentration in air-steam mixture during the transients

    International Nuclear Information System (INIS)

    Gorbenko, Gennady A.; Gakal, Pavlo G.; Epifanov, Konstantin S.; Osokin, Gennady V.; Smirnov, Sergey V.

    2006-01-01

    Description of system for air concentration measuring in air-steam mixture during the transients is represented. Air concentration measuring is based on discrete sampling method. The measuring system consists of sampler, transport pipeline, distributor and six measuring vessels. From the sampler air-steam mixture comes to distributor through transport pipeline and fills consecutively the measuring vessels. The true air concentration in place of measurement was defined based on measured air concentration in samples taken from measuring vessels. For this purpose, the mathematical model of transients in measuring system was developed. Air concentration transient in air-steam mixture in place of measurement was described in mathematical model by air concentration time-dependent function. The function parameters were defined based on air concentration measured in samples taken from measuring vessels. Estimated error of air concentration identification was about 10%. Measuring system was used in experiments on EREC BKV-213 test facility intended for testing of VVER-440/V-213 reactor barbotage-vacuum system

  14. Port Harcourt Medical Journal, a paradigm shift | Eke | Port Harcourt ...

    African Journals Online (AJOL)

    Port Harcourt Medical Journal, a paradigm shift. N Eke. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4103/0795-3038.179439 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors ...

  15. The VisPort Project: Visualization of Port Logistics

    Science.gov (United States)

    Katsioloudis, Petros J.; Watson, Ginger

    2011-01-01

    There is concern about the diminishing availability of skilled personnel that can operate in the wide variety of disciplines associated with port operations. Increasing cargo volume, combined with a shrinking workforce, could potentially create alarming situations in the future, hence the motivation to publicize to current students the breadth and…

  16. Creating safer coastal and port infrastructure with innovative physical and numerical modelling

    CSIR Research Space (South Africa)

    Tulsi, K

    2015-10-01

    Full Text Available Infrastructure with Innovative Physical and Numerical Modelling Kishan Tulsi  Physical and Numerical modelling  Breakwater Monitoring  Armour track  Vessel manoeuvring simulations for safe port design and operations  Simflex software... – Integrated Port Operations Support System  Virtual Buoy Physical modelling Numerical modelling Armour Track Armour Track Armour Track Armour Track Armour track using 3D data points Ship manoeuvring simulations: Ship Manoeuvring simulations Port...

  17. Design and simulation of a low concentrating photovoltaic/thermal system

    International Nuclear Information System (INIS)

    Rosell, J.I.; Vallverdu, X.; Lechon, M.A.; Ibanez, M.

    2005-01-01

    The advantages of photovoltaic/thermal (PV/T) collectors and low solar concentration technologies are combined into a photovoltaic/thermal system to increase the solar energy conversion efficiency. This paper presents a prototype 11X concentration rate and two axis tracking system. The main novelty is the coupling of a linear Fresnel concentrator with a channel photovoltaic/thermal collector. An analytical model to simulate the thermal behaviour of the prototype is proposed and validated. Measured thermal performance of the solar system gives values above 60%. Theoretical analysis confirms that thermal conduction between the PV cells and the absorber plate is a critical parameter

  18. Investigation of the environmental radioactivity around the mooring port

    International Nuclear Information System (INIS)

    Tanigawa, Yoshio

    1976-01-01

    Here are the main data for radioactivity examination performed in 1975 at Mutsu port, the mooring port of atomic energy vessel ''Mutsu''. No abnormality were observed in space γ ray dose ratio, and integrated doses measured by the thermofluorescence dosimeter at three monitoring posts in the port (G M tube) and three monitoring station in Mutsu City. A serial measurement of radioactivity concentration in sea water did not show any abnormality, either. Samples were taken from the surface soil of the ground, the bottom of the rivers, river water, drinking water, and milk and measured the total radioactivity by a gas flow counter. The measurement of the total β-radioactivity and radio nuclides analysis were carried out in sea water, the soil from the bottom of the sea and sea products. Abnormality considered to be caused by ''Mutsu'' did not observed at all. (Kobatake, H.)

  19. Bacterial concentration detection using a portable embedded sensor system for environmental monitoring

    OpenAIRE

    Grossi , Marco; Riccò , Bruno; Parolin , Carola; Vitali , Beatrice

    2017-01-01

    International audience; The detection of bacterial concentration is important in different fields since high microbial contamination or the presence of particular pathogens can seriously endanger human health. The reference technique to measure bacterial concentration is Standard Plate Count (SPC) that, however, has long response times (24 to 72 hours) and is not suitable for automatic implementation. This paper presents a portable embedded system for bacterial concentration measurement based...

  20. Why are maritime ports (still) urban and why should policymakers care?

    NARCIS (Netherlands)

    Hall, P.V.; Jacobs, W.A.A.

    2012-01-01

    Despite ongoing transformations in the maritime transportation industry and the rise of global supply chain systems, most of the world’s important container ports remain urban. Ports continue to occupy urban spaces, are embedded in localized knowledge systems, draw on urban labour markets and

  1. Image-based visual servo control using the port-Hamiltonian Approach

    NARCIS (Netherlands)

    Muñoz Arias, Mauricio; El Hawwary, Mohamed; Scherpen, Jacquelien M.A.

    2015-01-01

    This work is devoted to an image-based visual servo control strategy for standard mechanical systems in the port-Hamiltonian framework. We utilize a change of variables that transforms the port-Hamiltonian system into one with constant mass-inertia matrix, and we use an interaction matrix that

  2. High-concentration mirror-based Kohler integrating system for tandem solar cells

    Science.gov (United States)

    Winston, R.; Benitez, P.; Cvetkovic, A.

    2006-06-01

    A novel two-mirror high concentration nonimaging optic has been designed that shares the advantages of present two mirror aplanatic imaging concentrators but also overcomes their main limitation of trade-off between acceptance angle and irradiance uniformity. A system concept has been defined, and a first prototype in under development.

  3. Influence of zirconium ion concentration in model extraction systems TBP - diluents - Zr+4 - nitric acid

    International Nuclear Information System (INIS)

    Rogoz, F.; Tlalka, M.

    1987-07-01

    In systems containing TBP, MBP, DBP and 1-butanol stable emulsions and precipitates are formed which separation is difficult in certain domain of concentration in zirconium ions. MPB and DBP increase stability of primary emulsion in kerosen and carbon tetrachloride but for different concentrations of nitric acid. Addition of 1-butanol decreases slightly the stability of primary emulsion [fr

  4. Ports Primer: 7.1 Environmental Impacts

    Science.gov (United States)

    Port operations can lead to environmental impacts on air, water and land. Many communities with environmental justice concerns also experience disparities in health outcomes that they attribute to exposure to emissions from port operations.

  5. Ports Primer: 7.0 Environmental Impacts

    Science.gov (United States)

    Port operations can lead to environmental impacts on air, water and land. Many communities with environmental justice concerns also experience disparities in health outcomes that they attribute to exposure to emissions from port operations.

  6. Estimation of Uncertainty in Aerosol Concentration Measured by Aerosol Sampling System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Chan; Song, Yong Jae; Jung, Woo Young; Lee, Hyun Chul; Kim, Gyu Tae; Lee, Doo Yong [FNC Technology Co., Yongin (Korea, Republic of)

    2016-10-15

    FNC Technology Co., Ltd has been developed test facilities for the aerosol generation, mixing, sampling and measurement under high pressure and high temperature conditions. The aerosol generation system is connected to the aerosol mixing system which injects SiO{sub 2}/ethanol mixture. In the sampling system, glass fiber membrane filter has been used to measure average mass concentration. Based on the experimental results using main carrier gas of steam and air mixture, the uncertainty estimation of the sampled aerosol concentration was performed by applying Gaussian error propagation law. FNC Technology Co., Ltd. has been developed the experimental facilities for the aerosol measurement under high pressure and high temperature. The purpose of the tests is to develop commercial test module for aerosol generation, mixing and sampling system applicable to environmental industry and safety related system in nuclear power plant. For the uncertainty calculation of aerosol concentration, the value of the sampled aerosol concentration is not measured directly, but must be calculated from other quantities. The uncertainty of the sampled aerosol concentration is a function of flow rates of air and steam, sampled mass, sampling time, condensed steam mass and its absolute errors. These variables propagate to the combination of variables in the function. Using operating parameters and its single errors from the aerosol test cases performed at FNC, the uncertainty of aerosol concentration evaluated by Gaussian error propagation law is less than 1%. The results of uncertainty estimation in the aerosol sampling system will be utilized for the system performance data.

  7. Lithography-free nanofluidic concentrator based on droplets-on-demand system

    Science.gov (United States)

    Yu, Miao; Zhou, Hongbo; Yao, Shuhuai

    2013-11-01

    Biomarkers are usually low-abundance proteins in biofluids and below detection limit of conventional biosensors. Nanofluidic concentration devices allow efficient biomolecules trapping by utilizing ion concentration polarization near nanochannels. However, once the electric field is turned off, the electrokinetic concentration plug cannot maintain its concentration status and starts to diffuse. In order to maintain the high concentration and extract the concentrated sample for further analysis, a good approach is to encapsulate these plugs into water-in-oil droplets. Here we developed a nanofluidic concentrator based on droplet-on-demand generator to encapsulate concentrated sample in nL droplets. The lithography-free nanochannels were patterned by thermal cracking on the surface of PS Petri-dish. The resulting nanochannel arrays were 30 nm in depth. In combination with microchannels on PDMS, the micro-nano hybrid chip was developed. We used FITC solution to demonstrate that the chip significantly increased the sample concentration for more than 100 folds within 5 minutes. By tuning the pulsed pressure imposed by the solenoid valve connected to the concentration channel, the system can generate a desired volume of droplet with a target sample concentration at a prescribed time. This work was supported by the Research Grants Council of Hong Kong under General Research Fund (Grant No. 621110).

  8. Modelling anaerobic digestion of concentrated black water and faecal matter in accumulation system

    NARCIS (Netherlands)

    Elmitwalli, T.; Zeeman, G.; Otterpohl, R.

    2011-01-01

    A dynamic mathematical model based on anaerobic digestion model no. 1 (ADM1) was developed for accumulation (AC) system treating concentrated black water and faecal matter at different temperatures. The AC system was investigated for the treatment of waste(water) produced from the following systems:

  9. Data concentrator card and test system for the CMS ECAL readout

    CERN Document Server

    Almeida, N; Alemany, R; Cardoso, N; Varela, J

    2003-01-01

    The Data Concentrator Card (DCC) is part of the Off-Detector (OD) Electronics sub-system of the CMS Electromagnetic Calorimeter. The DCC is responsible for crystal and trigger data collection from the Front-End system and from the ECAL Trigger system respectively.

  10. Design and experimental investigation of a Multi-segment plate concentrated photovoltaic solar energy system

    International Nuclear Information System (INIS)

    Wang, Gang; Chen, Zeshao; Hu, Peng

    2017-01-01

    Highlights: • A multi-segment plate concentrated photovoltaic solar energy system was proposed. • A prototype of this new concentrator was developed for experimental investigation. • Experimental investigation results showed a good concentrating uniformity. - Abstract: Solar energy is one of the most promising renewable energies and meaningful for the sustainable development of energy source. A multi-segment plate concentrated photovoltaic (CPV) solar power system was proposed in this paper, the design principle of the multi-segment plate concentrator of this solar power system was given, which could provide uniform solar radiation flux density distribution on solar cells. A prototype of this multi-segment plate CPV solar power system was developed for the experimental study, aiming at the investigations of solar radiation flux density distribution and PV performances under this concentrator design. The experimental results showed that the solar radiation flux density distribution provided by the multi-segment plate concentrator had a good uniformity, and the number and temperature of solar cells both influence the photoelectric transformation efficiency of the CPV solar power system.

  11. High concentration of Daunorubicin and Daunorubicinol in human malignant astrocytomas after systemic administration of liposomal Daunorubicin

    NARCIS (Netherlands)

    Albrecht, K. W.; de Witt Hamer, P. C.; Leenstra, S.; Bakker, P. J.; Beijnen, J. H.; Troost, D.; Kaaijk, P.; Bosch, A. D.

    2001-01-01

    The value of chemotherapy in patients with malignant astrocytoma remains controversial. In our laboratories in vitro experiments with organotypic spheroid cultures showed superior effectiveness of anthracyclines. Systemic administration did not provide in therapeutic concentrations so far. Because

  12. Using Potentiometric Free Drug Sensors to Determine the Free Concentration of Ionizable Drugs in Colloidal Systems

    DEFF Research Database (Denmark)

    Tran, Thuy; Chakraborty, Anjan; Xi, Xi

    2018-01-01

    The present study investigates the use of free drug sensors (FDS) to measure free ionized drug concentrations in colloidal systems, including micellar solutions, emulsions, and lipid formulations during in vitro lipolysis. Diphenhydramine hydrochloride (DPH) and loperamide hydrochloride (LOP) wer...

  13. Design factors of sensors for the optical tracking systems of solar concentrators

    International Nuclear Information System (INIS)

    Klychev, Sh. I.; Fazylov, A. K.; Orlov, S. A.; Burbo, A. V.

    2011-01-01

    Basic diagrams for the sensors of the optical tracking systems of solar concentrators are considered, the design factors that determine their accuracy are analyzed, a new sensor design is suggested, and its optimal parameters are determined. (authors)

  14. Increasing Fuel Efficiency of Direct Methanol Fuel Cell Systems with Feedforward Control of the Operating Concentration

    Directory of Open Access Journals (Sweden)

    Youngseung Na

    2015-09-01

    Full Text Available Most of the R&D on fuel cells for portable applications concentrates on increasing efficiencies and energy densities to compete with other energy storage devices, especially batteries. To improve the efficiency of direct methanol fuel cell (DMFC systems, several modifications to system layouts and operating strategies are considered in this paper, rather than modifications to the fuel cell itself. Two modified DMFC systems are presented, one with an additional inline mixer and a further modification of it with a separate tank to recover condensed water. The set point for methanol concentration control in the solution is determined by fuel efficiency and varies with the current and other process variables. Feedforward concentration control enables variable concentration for dynamic loads. Simulation results were validated experimentally with fuel cell systems.

  15. Single port Billroth I gastrectomy

    Directory of Open Access Journals (Sweden)

    Jeremy R Huddy

    2013-01-01

    Full Text Available Introduction: Experience has allowed increasingly complex procedures to be undertaken by single port surgery. We describe a technique for single port Billroth I gastrectomy with a hand-sewn intracorporeal anastomosis in the resection of a benign tumour diagnosed incidentally on a background of cholelithiasis. Materials and Methods: Single port Billroth I gastrectomy and cholecystectomy was performed using a transumbilical quadport. Flexible tipped camera and straight conventional instruments were used throughout the procedure. The stomach was mobilised including a limited lymph node dissection and resection margins in the proximal antrum and duodenum were divided with a flexible tipped laparoscopic stapler. The lesser curve was reconstructed and an intracorporal hand sewn two layer end-to-end anastomosis was performed using unidirectional barbed sutures. Intraoperative endoscopy confirmed the anastomosis to be patent without leak. Results: Enteral feed was started on the day of surgery, increasing to a full diet by day 6. Analgesic requirements were a patient-controlled analgesia morphine pump for 4 postoperative days and paracetamol for 6 days. There were no postoperative complications and the patient was discharged on the eighth day. Histology confirmed gastric submucosal lipoma. Discussion: As technology improves more complex procedures are possible by single port laparoscopic surgery. In this case, flexible tipped cameras and unidirectional barbed sutures have facilitated an intracorporal hand-sewn two layer end-to-end anastomosis. Experience will allow such techniques to become mainstream.

  16. Port Harcourt Medical Journal: Submissions

    African Journals Online (AJOL)

    Port Harcourt Medical Journal (PMJ) is a general medical journal that will consider any original contribution that advances or illuminates medical science or ... The covering letter must include information on prior or duplicate publication and a statement of financial or other relationships that might lead to a conflict of interest.

  17. Integration of Land and Sea in a Port Area: A Case Study of the Port of Koper

    Science.gov (United States)

    Ažman Momirski, Lucija

    2017-10-01

    The spatial plan for a port based on land reclamation, existing land, or a combination of both should be designed in line with both reliable data for the existing situation and precise goals based on a well-founded vision by the port authority. In ports, human activities are concentrated in the limited space of the coastal belt, where they threaten the vulnerable equilibrium of the environment. Integrated multifunctional planning of ports is necessary for the sustainability of such plans. In this process, the relation between the environment and the economy is often neglected because the ecosystem—the totality of living organisms—which is fully dependent on biological, chemical, and physical factors, prevails. This method, also called building with nature, is the basis for integrated coastal zone development and management. It emphasizes the flexible integration of land and sea, which respects and uses forces and materials present in nature, and which is an essential interaction between man and environment. Strict ecological planning conditions and the public interest obliged the Port of Koper to modify its urban planning strategies and redefine its relationship with all bordering areas. The extension of two piers and construction of a third one was the result of functional factors, infrastructure connections, technical possibilities, and environmental requirements. Solutions that were relevant for distributing cargo on the docks had to adjust to the width of the basins for manoeuvring ships. Various types of construction restrict water flow under piers, thereby accelerating biomass degradation. Environmental aspects created conditions and requirements for pier construction.

  18. Cyber security in ports: Business as usual

    OpenAIRE

    Moerel, Lokke; Dezeure, Freddy

    2017-01-01

    Our paper summarizes the risks and provides concrete and pragmatic proposals to increase substantially the cyber maturity and resilience in the ports by organizing training and awareness raising, fostering cooperation and information exchange both between the stakeholders in the ports and across the ports and integrating the cyber risk into the physical security risk management processes and structures already in place within the ports. This also involves a higher degree of oversight by the P...

  19. Compressor ported shroud for foil bearing cooling

    Science.gov (United States)

    Elpern, David G [Los Angeles, CA; McCabe, Niall [Torrance, CA; Gee, Mark [South Pasadena, CA

    2011-08-02

    A compressor ported shroud takes compressed air from the shroud of the compressor before it is completely compressed and delivers it to foil bearings. The compressed air has a lower pressure and temperature than compressed outlet air. The lower temperature of the air means that less air needs to be bled off from the compressor to cool the foil bearings. This increases the overall system efficiency due to the reduced mass flow requirements of the lower temperature air. By taking the air at a lower pressure, less work is lost compressing the bearing cooling air.

  20. Field test analysis of concentrator photovoltaic system focusing on average photon energy and temperature

    Science.gov (United States)

    Husna, Husyira Al; Ota, Yasuyuki; Minemoto, Takashi; Nishioka, Kensuke

    2015-08-01

    The concentrator photovoltaic (CPV) system is unique and different from the common flat-plate PV system. It uses a multi-junction solar cell and a Fresnel lens to concentrate direct solar radiation onto the cell while tracking the sun throughout the day. The cell efficiency could reach over 40% under high concentration ratio. In this study, we analyzed a one year set of environmental condition data of the University of Miyazaki, Japan, where the CPV system was installed. Performance ratio (PR) was discussed to describe the system’s performance. Meanwhile, the average photon energy (APE) was used to describe the spectrum distribution at the site where the CPV system was installed. A circuit simulator network was used to simulate the CPV system electrical characteristics under various environmental conditions. As for the result, we found that the PR of the CPV systems depends on the APE level rather than the cell temperature.

  1. COMPARATIVE ANALYSIS OF LEADING PORTS OF LATVIA: COMPETITIVENESS OF LIEPAJA PORT

    Directory of Open Access Journals (Sweden)

    Diāna Līduma

    2015-06-01

    Full Text Available There are 10 operating ports in Latvia and 3 of them – Liepaja, Ventspils and Riga ports are regarded as the leading commercial ports. Role of port operation in the economics of region and country is essential from the point of view of employment and entrepreneurship. This is based with data on investment of operation of Latvian ports in GDP, on average it is assessed to be 5-7% annually. In the context of employment, Liepaja Port gives work to 6.9% of human resources of the city. However, concern about the competitiveness of Liepaja Port influenced by the proximity of more developed competitive ports, technical possibilities of the port and dynamics of freight turnover has occurred in recent years. Therewith in framework of this article in the context of such criteria as location of ports and their technical parameters, volumes of freight, specialization and costs of ports, the operation of leading ports of Latvia is intercompared and analyzed by clarifying whether Liepaja Port is competitive among other ports of Latvia. Opinions of port experts on perspectives of port development and statistical data of ports from 2011-2013 are analyzed within the framework of the article. The aim of the research is to clarify the comparative advantages of ports of Latvia. The research revealed that the provision of competitiveness of Liepaja Port is to be related with application of the available free territories, advantages of location in relation to the Scandinavian market, and the necessity to develop the cooperation among ports of Latvia to offer joint freight acquisition, distributions and unified logistics solution and strengthen the position of ports in the circumstances of international competition.

  2. Multi-functional use of port areas

    NARCIS (Netherlands)

    Ros, R.; Taneja, P.; Vellinga, T.

    2012-01-01

    The core business of a port is handling vessels and cargo. In addition a landlord Port Authority invests in development of port areas. However, in view of the new trends such as stakeholders interests related to environment and sustainability, it is can be wise to reexamine the business portfolio

  3. 50 CFR 24.12 - Designated ports.

    Science.gov (United States)

    2010-10-01

    ...) The U.S. Department of Agriculture ports at Hilo, Hawaii, and Chicago, Illinois, are designated ports..., Florida Atlanta, Georgia Savannah, Georgia Agana, Guam Hilo, Hawaii Honolulu, Hawaii Wailuku, Maui, Hawaii... Orlando, Florida Honolulu, Hawaii New Orleans, Louisiana Hoboken, New Jersey (Port of New York) Jamaica...

  4. Ports and Terminals : Planning and Functional Design

    NARCIS (Netherlands)

    Groenveld, R.; Velsink, H.

    1993-01-01

    1. Maritime transport, means and commodities 3. Principles of integrated port planning 4. Planning and design of a port's water areas 5. Port terminals - introduction 6. Conventional general cargo terminals 7. Container terminals 8. Oil & liquid gas terminals 9. Dry bulk cargo terminals 10. Fishery

  5. Starting manufacturing phase of ITER upper ports

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yuri, E-mail: yuri.utin@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Fabritsiev, Sergey [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Giraud, Benoit; Guirao, Julio [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Koenig, Werner [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Kedrov, Igor; Kuzmin, Evgeny [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Levesy, Bruno; Martinez, Jean-Marc [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Prebeck, Markus [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Privalova, Elena [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Ranzinger, Franz [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Savrukhin, Petr [Russian Federation ITER Domestic Agency, Kurchatov sq.1, 123182 Moscow (Russian Federation); Schiller, Thomas [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); and others

    2015-10-15

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  6. Starting manufacturing phase of ITER upper ports

    International Nuclear Information System (INIS)

    Utin, Yuri; Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James; Fabritsiev, Sergey; Giraud, Benoit; Guirao, Julio; Koenig, Werner; Kedrov, Igor; Kuzmin, Evgeny; Levesy, Bruno; Martinez, Jean-Marc; Prebeck, Markus; Privalova, Elena; Ranzinger, Franz; Savrukhin, Petr; Schiller, Thomas

    2015-01-01

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  7. Lithium isotope effect in the extraction systems of polyethers: effect of salt concentration

    International Nuclear Information System (INIS)

    Fang Shengqiang; Fu Lian

    1991-01-01

    Separation factors of lithium isotopes at 20 deg C were determined in the extraction systems of B15C5-CHCl 3 /LiBr-H 2 O. The initial concentration of LiBr was controlled in the extent of more than 2 mol/l. It may be established that the increase of LiBr concentration causes a remarkable increase of the separation factor. The essence of this effect due to the change in salt concentration was discussed in connection with examination of relevant phenomena in literature. It can be concluded that the relationship between α and Cm, the concentration of lithium salt, is dependent on K Q and K P express respectively, lithium isotope exchange equilibrium constants between Li-crownether complex and hydrated lithium ion for lithium concentration less than 1-2 mol/l, and between lithium salt ion pair and hydrated lithium ion for lithium concentration more than 2 mol/l in aqueous phase

  8. Improving the competitiveness of the Spanish port system by optimizing the cargo service; Mejora de la competitividad del Sistema Portuario Espanol mediante la optimizacion del servicio de manipulacion de mercancias

    Energy Technology Data Exchange (ETDEWEB)

    Almazan Garate, J. L.; Parra Serrano, M. P.

    2012-07-01

    Port services are responsible for most of the cost for the passing of goods through the port, especially the cargo handling service. Reliability and efficiency in the provision of them are key in a sector where there is a high opacity. With this study, we provide the responsible Administration, the Port Authority, with a tool that will help to objectify the decision making process, both at the time of granting the required licenses and during the period of the service provision. Also, proposes a number of measures w hoses implementation would improve the conditions of the service delivery and will reduce the total cost of transporting goods through the port. (Author) 11 refs.

  9. Perancangan Miniatur Traffic Light Dengan Mempergunakan Pengendali Port Paralel

    OpenAIRE

    Eka Wahyudi; Desi Permanasari

    2012-01-01

    Port paralel tentunya sudah tidak asing lagi dalam dunia komputer. Hal tersebut disebabkan karena port paralel merupakan sarana komunikasi yang terdapat pada Personal Computer (PC). Dengan memanfaatkan port tersebut, saat ini komputer juga dapat dipergunakan untuk keperluan pengontrolan/pengendalian rangkaian listrik dengan memanfaatkan port paralel (port printer). Port paralel memiliki kecepatan transfer data yang lebih cepat apabila dibandingkan dengan port serial, maka dari itu port parale...

  10. Design construction and analysis of solar ridge concentrator photovoltaic (PV) system to improve battery charging performance.

    Science.gov (United States)

    Narasimman, Kalaiselvan; Selvarasan, Iniyan

    2016-05-01

    A ridge concentrator photovoltaic system for a 10W multi-crystalline solar panel was designed with the concentration ratios of 1X and 2X. The ray tracing model of ridge concentrator photovoltaic system was carried out using Trace-Pro simulation. The optimum tilt angle for the concentrator PV system throughout the year was computed. The electrical parameters of the 3 panels were analyzed. The effect of temperature on the electrical performance of the panel was also studied. The reduction of voltage due to increasing panel temperature was managed by MPES type Charge controller. Glass reflector with reflectivity 0.95 was chosen as the ridge wall for the concentrator system. The maximum power outputs for the 1X and 2X panel reached were 9W and 10.5W with glass reflector. The percentage of power improvement for 1X and 2X concentrations were 22.3% and 45.8% respectively. The 2X concentrated panel connected battery takes lower time to charge compared with normal panel connected battery. Copyright © 2016. Published by Elsevier Inc.

  11. Optimization of wireless power transmission for two port and three port inductive link

    International Nuclear Information System (INIS)

    Haider, Samnan; Mansor, Hasmah; Khan, Sheroz; Arshad, Atika; Shobaki, Mohammed M; Tasnim, Rumana

    2013-01-01

    Recent developments have shown that the use of buried electronic devices or body implants has been becoming prevalent. Such low power devices are being powered up through non-contact means utilizing inductive coupling from external powering source. Inductive coupling not only solves the issue of energy availability but helps collecting the sensed data that can be archived or used for subsequent monitoring purposes. This paper analyses the performance of two-port and three-port inductive links in terms of power sent, power received and power transfer efficiency. All the above mentioned parameters have been plotted using analytical approach and obtaining simulation where required. The effect of mutual coupling has been studied in detail for both systems and demonstrated by plotting the power transfer efficiency for different values of the coefficient of coupling (k) using MATLAB. Results show that power transfer efficiency depends highly upon the value of k

  12. Vectorization, parallelization and porting of nuclear codes. 2001

    International Nuclear Information System (INIS)

    Akiyama, Mitsunaga; Katakura, Fumishige; Kume, Etsuo; Nemoto, Toshiyuki; Tsuruoka, Takuya; Adachi, Masaaki

    2003-07-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the super computer system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 10 codes in fiscal 2001. In this report, the parallelization of Neutron Radiography for 3 Dimensional CT code NR3DCT, the vectorization of unsteady-state heat conduction code THERMO3D, the porting of initial program of MHD simulation, the tuning of Heat And Mass Balance Analysis Code HAMBAC, the porting and parallelization of Monte Carlo N-Particle transport code MCNP4C3, the porting and parallelization of Monte Carlo N-Particle transport code system MCNPX2.1.5, the porting of induced activity calculation code CINAC-V4, the use of VisLink library in multidimensional two-fluid model code ACD3D and the porting of experiment data processing code from GS8500 to SR8000 are described. (author)

  13. HFB : A FASTBUS multi event double port buffer memory

    International Nuclear Information System (INIS)

    Cerrito, L.; Lebbolo, H.

    1986-01-01

    The authors describe here the FB double port buffer memory developed at the LPNHE of the University Paris VI. Its purposes are to make available same features useful in the High Energy environment, to reduce, for a given amount of memory, the dead time data collection in a large size (in term of read-out channels) High Energy experiment and to get a buffer of memory as cheap and reliable as possible. The FB protocol, on the crate and cable side, is exploited using the coupler on 4 PAL's developed by G.Fremont and E.Sanchis. The DATA-Space is divided in 4 independent smaller blocks in a way such that a block can be accessed from a port while a different block is accessed from the other port. The two ports are: A, the FB crate port and B, the FB cable port. The buffer works as a rotary FIFO, looping over the 4 blocks of memory, but allowing for any random access. A mechanism is implemented on the board in order to be able to link different modules placed everywhere. If there are m modules, the looping will be around m 4 memory blocks. A multi event function is implemented on the board. HFB is quiped of two NTA for the DATA-Space on the port ''A'', and a flag to choose between them, to allow for a FB spying of DATA during the DAS dead time. HFB is a buffer of memory which can be used at each stage of a DAS: Frontend, Intermediate (MEB) or final, being completely FB standard. The HFB was designed for the LEP data acquisition system

  14. 78 FR 36014 - Deepwater Port License Application: Liberty Natural Gas, LLC, Port Ambrose Deepwater Port

    Science.gov (United States)

    2013-06-14

    ... timeline for processing an application. When MarAd and USCG determine that an application contains the... that Port Ambrose falls within the proposed area of interest for the New York Power Authority Long Island-New York City Offshore Wind Project. This project will be acknowledged and considered in the...

  15. An overview of San Francisco Bay PORTS

    Science.gov (United States)

    Cheng, Ralph T.; McKinnie, David; English, Chad; Smith, Richard E.

    1998-01-01

    The Physical Oceanographic Real-Time System (PORTS) provides observations of tides, tidal currents, and meteorological conditions in real-time. The San Francisco Bay PORTS (SFPORTS) is a decision support system to facilitate safe and efficient maritime commerce. In addition to real-time observations, SFPORTS includes a nowcast numerical model forming a San Francisco Bay marine nowcast system. SFPORTS data and nowcast numerical model results are made available to users through the World Wide Web (WWW). A brief overview of SFPORTS is presented, from the data flow originated at instrument sensors to final results delivered to end users on the WWW. A user-friendly interface for SFPORTS has been designed and implemented. Appropriate field data analysis, nowcast procedures, design and generation of graphics for WWW display of field data and nowcast results are presented and discussed. Furthermore, SFPORTS is designed to support hazardous materials spill prevention and response, and to serve as resources to scientists studying the health of San Francisco Bay ecosystem. The success (or failure) of the SFPORTS to serve the intended user community is determined by the effectiveness of the user interface.

  16. Maintaining and Researching Port Safety: A Case Study of the Port of Kaohsiung

    OpenAIRE

    Tseng, Po-Hsing.; Pilcher, Nick.

    2017-01-01

    Maintaining port safety in full conformity with IMO standards is a requisite for every port and country. To do this, understanding the challenges and human factors involved is key. To date, much research has shed valuable light on these factors and considered how to address them. One aspect that is often noted is that both maintaining port safety and researching port safety presents numerous challenges. This paper considers both these aspects in the context of a case study of port safety in K...

  17. Materials for Concentrator Photovoltaic Systems: Optical Properties and Solar Radiation Durability

    Science.gov (United States)

    French, R. H.; Rodríguez-Parada, J. M.; Yang, M. K.; Lemon, M. F.; Romano, E. C.; Boydell, P.

    2010-10-01

    Concentrator photovoltaic (CPV) systems are designed to operate over a wide range of solar concentrations, from low concentrations of ˜1 to 12 Suns to medium concentrations in the range from 12 to 200 Suns, to high concentration CPV systems going up to 2000 Suns. Many transparent optical materials are used for a wide variety of functions ranging from refractive and reflective optics to homogenizers, encapsulants and even thermal management. The classes of materials used also span a wide spectrum from hydrocarbon polymers (HCP) and fluoropolymers (FP) to silicon containing polymers and polyimides (PI). The optical properties of these materials are essential to the optical behavior of the system. At the same time radiation durability of these materials under the extremely wide range of solar concentrations is a critical performance requirement for the required lifetime of a CPV system. As part of our research on materials for CPV we are evaluating the optical properties and solar radiation durability of various polymeric materials to define the optimum material combinations for various CPV systems.

  18. Ecological land classification and terrestrial environment effects assessment for the Port Hope and Port Granby projects

    International Nuclear Information System (INIS)

    Taylor, M.; Wittkugel, U.; Kleb, H.

    2006-01-01

    The Ecological Land Classification system was developed to provide a standardized methodology for describing plant communities and wildlife habitat in southern Ontario. The method employs a hierarchical classification system. It can be applied at different levels of accuracy, i.e., at regional, sub-regional, and local scales with an increasing differentiation of vegetation communities. The standardization of the approach permits a comparison of vegetation communities from different sites and an evaluation of the rarity of these communities within the province. Further, the approach facilitates the monitoring of changes in terrestrial communities with time. These characteristics make Ecological Land Classification mapping a useful tool for environmental assessment such as the ones undertaken for the Port Hope and Port Granby Long-Term Waste Management Projects, which were conducted pursuant to the Canadian Environmental Assessment Act 1992. In the context of the Environmental Assessment for the Port Hope and Port Granby Projects, an Ecological Land Classification study was undertaken to characterize the terrestrial environment at regional, local and site levels. Vegetation patches (polygons) were delineated on the basis of air photo interpretation. The individual polygons were then visited for detailed inventory and classified to the most detailed level; that is to the vegetation type. Plant communities were then compared with those listed in the Ontario Natural Heritage Information Centre database to determine their rarity and to determine where they rank as Valued Ecosystem Components. Ecological Land Classification mapping results were used in the assessment of effects to Valued Ecosystem Components. A spatial analysis of the digitized vegetation maps showed the geographic extent of habitat losses and impairments due to various project works and activities. Landscape rehabilitation strategies and concepts were subsequently developed based on Ecological Land

  19. Temporary vs. Permanent Sub-slab Ports: A Comparative ...

    Science.gov (United States)

    Vapor intrusion (VI) is the migration of subsurface vapors, including radon and volatile organic compounds (VOCs), from the subsurface to indoor air. The VI exposure pathway extends from the contaminant source, which can be impacted soil, non-aqueous phase liquid, or contaminated groundwater, to indoor air-exposure points. Therefore, contaminated matrices may include groundwater, soil, soil gas, and indoor air. VOC contaminants of concern typically include halogenated solvents such as trichloroethene, tetrachloroethene, and chloroform, as well as petroleum hydrocarbons, such as the aromatic VOCs benzene, toluene, and xylenes. Radon is a colorless radioactive gas that is released by radioactive decay of radionuclides in rock and soil that migrate into homes through VI in a similar fashion to VOCs. This project focused on the performance of permanent versus temporary sub-slab sampling ports for the determination of VI of halogenated VOCs and radon into an unoccupied house. VOC and radon concentrations measured simultaneously in soil gas using collocated temporary and permanent ports appeared to be independent of the type of port. The variability between collocated temporary and permanent ports was much less than the spatial variability between different locations within a single residential duplex. The agreement of the majority of VOC and radon concentrations, 0–36% relative percent difference, and 2–19% relative standard deviation respectively, of each sub-sl

  20. Optimization of a Point Focus Concentration Photovoltaic System with Passive Cooling

    International Nuclear Information System (INIS)

    Chenlo, F.

    2015-01-01

    The objective of this work is modeling the temperature of photovoltaic (PV) solar cells operating in concentration systems with circular geometry and coupled to a heat sink plate for passive cooling. The proposed thermal behavior model analyses the temperature surface distribution of both PV solar cell and heat sink plate as function of light concentration. The model also allows analyzing the influence of other parameters such as uniform and non-uniform variation of the heat sink plate thickness or variation of the thermal transmission coefficient. The optimal range of the concentration factor is studied using simple models for the PV solar cell efficiency and Fresnel lens concentrator performance together with a function of costs applied to medium concentration silicon crystalline PV cells and high efficiency and high concentration multi-junction PV cells. Finally, experimental main parameters and its procedures measurement for concentration systems are presented. Modeling results show that the use of a high conductivity disk thermally coupled between the rear side of the cell and the cooling plate reduces the working cell temperature. Results also indicates that use of a light redirecting prism by total internal reflection of sunlight, reduces optical losses due to concentrator defects and chromatic aberration and increases the angle tracking error acceptance without having to increase the area of the PV solar cell

  1. Hub Status and Indexation of Container Ports

    Directory of Open Access Journals (Sweden)

    Yong-An Park

    2015-06-01

    This study develops two sub-indexes of port classification and capacity, and combines cases of these two sub-indexes into various types in order to find a proper port hub index. The paper demonstrates how different types of port hub index are useful measurements for evaluating outputs and inputs of container ports. In a case analysis we show that the indexes of period variables and lagged variables have more explanatory power with regard to changes of port throughputs and high correlation with inputs.

  2. Overtopping hazards to port activities: Application of a new methodology to risk management (POrt Risk MAnagement Tool)

    International Nuclear Information System (INIS)

    Alises, Ana; Molina, Rafael; Gómez, Rebeca; Pery, Pascual; Castillo, Carmen

    2014-01-01

    In the past 20 years, the need of ports to serve a fleet whose dimensions are continuously increasing due to economies of scale, has derived on a port infrastructures growth with a trend to look for greater drafts at deeper waters and therefore the protection structures built in the last years have been increasingly exposed to severer maritime climate action. Consequently, overtopping phenomenon has been identified as a potential risk factor able to cause structural damages and operative failure modes to vulnerable economic activities located at these port facilities. Port activities must be developed ensuring operative and safety conditions what imply reducing uncertainties of overtopping phenomena by using prediction methods which may allow overtopping risk management. This paper provides a risk assessment methodology which is integrated into an overtopping risk management framework to cope with safety problems in port exploitation. Overtopping risk value is measured by combining probability of occurrence of an undesirable event together with its consequences, estimated in terms of costs or delays and given in base of the vulnerability of the affected port system. The development of this methodology is described and finally applied to a real case study what seems to reinforce the validity of the proposed method to overtopping risk assessment. - Highlights: • Infrastructure risk assessment involves both probabilistic and economic techniques. • Risk equation is posed by the combination of probability, vulnerability and cost. • Port infrastructures' vulnerability level depends on climate agents' action. • Economic value of natural hazards consequences is linked with vulnerability level. • Project planning process should be done taking into account the project's risk distribution

  3. A survey of antifoulants in sediments from Ports and Marinas along the French Mediterranean coast.

    Science.gov (United States)

    Cassi, Roberto; Tolosa, Imma; de Mora, Stephen

    2008-11-01

    Due to deleterious effects on non-target organisms, the use of organotin compounds on boat hulls of small vessels (ports and marinas along the France Mediterranean coastline (Cote d'Azur) and analysed for organotin compounds, Irgarol 1051, Sea-nine 211, Chlorothalonil, Dichlofluanid and Folpet. Every port and marina exhibited high levels of organotin compounds, with concentrations in sediments ranging from 37 ng Sn g(-1) dry wt in Menton Garavan to over 4000 ng Sn g(-1) dry wt close to the ship chandler within the port of Villefranche-sur-Mer. TBT degradation indexes suggested that fresh inputs are still made. Among the other antifoulants monitored, only Irgarol 1051 exhibited measurable concentrations in almost every port, with concentrations ranging from 40 ng g(-1) dry wt (Cannes) to almost 700 ng g(-1) dry wt (Villefranche-sur-Mer, ship chandler).

  4. Terrestrial photovoltaic power systems with sunlight concentration. Annual progress report, January 1, 1975--December 31, 1975

    Energy Technology Data Exchange (ETDEWEB)

    Backus, C.E.

    1976-01-31

    This annual report is for the second year of a program to investigate the characteristics of the components and the total system using sunlight concentrated onto solar cells. The second year was primarily to experimentally investigate the conclusions of the first year of analytical studies. Cells have been fabricated that are designed for different intensities. Typically the efficiency of a cell will increase from its 11 percent at AM1 peak to efficiency at the designed concentration level and return to its initial efficiency at about 3 times its designed concentration level. The developed cells have been tested under high intensity simulators and in concentrated sunlight and have shown to have the predicted response. The experimental testing of passive cooling limitations for cooling cells with just finned arrangements in the back of the cell has been completed in the controlled environment of a wind tunnel. These experiments have confirmed the heat transfer coefficients that had been used in the analytical studies. Testing was done to collect heat transfer coefficients for actual wind conditions and these data show good agreement with the controlled wind tunnel data. Four photovoltaic/concentrator system experiments have been started with CR of about 3, 10, 25, and 100. System analysis has indicated that photovoltaic concentration systems may be attractive in low solar irradiation areas such as Cleveland.

  5. A Proposed Concentration Curriculum Design for Big Data Analytics for Information Systems Students

    Science.gov (United States)

    Molluzzo, John C.; Lawler, James P.

    2015-01-01

    Big Data is becoming a critical component of the Information Systems curriculum. Educators are enhancing gradually the concentration curriculum for Big Data in schools of computer science and information systems. This paper proposes a creative curriculum design for Big Data Analytics for a program at a major metropolitan university. The design…

  6. A concentrator system for BI-CPVT with static linear Fresnel lenses

    NARCIS (Netherlands)

    Swinkels, G.L.A.M.; Sonneveld, P.J.; Tuijl, van B.A.J.; Janssen, H.J.J.; Zwart, de H.F.

    2011-01-01

    A greenhouse with Fresnel lenses in the south facing roof and a receiver for concentrated Photovoltaic with water cooling (CPVT system) will result in electrical and thermal energy output from the solar energy excess entering a greenhouse. The PV system converts about half of the direct radiation

  7. Design and Operation of an Electrochemical Methanol Concentration Sensor for Direct Methanol Fuel Cell Systems

    Science.gov (United States)

    Narayanan, S. R.; Valdez, T. I.; Chun, W.

    2000-01-01

    The development of a 150-Watt packaged power source based on liquid feed direct methanol fuel cells is being pursued currently at the Jet propulsion Laboratory for defense applications. In our studies we find that the concentration of methanol in the fuel circulation loop affects the electrical performance and efficiency the direct methanol fuel cell systems significantly. The practical operation of direct methanol fuel cell systems, therefore, requires accurate monitoring and control of methanol concentration. The present paper reports on the principle and demonstration of an in-house developed electrochemical sensor suitable for direct methanol fuel cell systems.

  8. Improving the Resilience of Major Ports and Critical Supply Chains to Extreme Coastal Flooding: a Combined Artificial Neural Network and Hydrodynamic Simulation Approach to Predicting Tidal Surge Inundation of Port Infrastructure and Impact on Operations.

    Science.gov (United States)

    French, J.

    2015-12-01

    Ports are vital to the global economy, but assessments of global exposure to flood risk have generally focused on major concentrations of population or asset values. Few studies have examined the impact of extreme inundation events on port operation and critical supply chains. Extreme water levels and recurrence intervals have conventionally been estimated via analysis of historic water level maxima, and these vary widely depending on the statistical assumptions made. This information is supplemented by near-term forecasts from operational surge-tide models, which give continuous water levels but at considerable computational cost. As part of a NERC Infrastructure and Risk project, we have investigated the impact of North Sea tidal surges on the Port of Immingham, eastern, UK. This handles the largest volume of bulk cargo in the UK and flows of coal and biomass that are critically important for national energy security. The port was partly flooded during a major tidal surge in 2013. This event highlighted the need for improved local forecasts of surge timing in relation to high water, with a better indication of flood depth and duration. We address this problem using a combination of data-driven and numerical hydrodynamic models. An Artificial Neural Network (ANN) is first used to predict the surge component of water level from meteorological data. The input vector comprises time-series of local wind (easterly and northerly wind stress) and pressure, as well as regional pressure and pressure gradients from stations between the Shetland Islands and the Humber estuary. The ANN achieves rms errors of around 0.1 m and can generate short-range (~ 3 to 12 hour) forecasts given real-time input data feeds. It can also synthesize water level events for a wider range of tidal and meteorological forcing combinations than contained in the observational records. These are used to force Telemac2D numerical floodplain simulations using a LiDAR digital elevation model of the port

  9. A kind of video image digitizing circuit based on computer parallel port

    International Nuclear Information System (INIS)

    Wang Yi; Tang Le; Cheng Jianping; Li Yuanjing; Zhang Binquan

    2003-01-01

    A kind of video images digitizing circuit based on parallel port was developed to digitize the flash x ray images in our Multi-Channel Digital Flash X ray Imaging System. The circuit can digitize the video images and store in static memory. The digital images can be transferred to computer through parallel port and can be displayed, processed and stored. (authors)

  10. The performance analysis of the Trough Concentrating Solar Photovoltaic/Thermal system

    Energy Technology Data Exchange (ETDEWEB)

    Li, M., E-mail: liming@ynnu.edu.c [Solar Energy Research Institute, Yunnan Normal University, 650092 Kunming (China); Li, G.L. [School of Physics and Electronic Information, Yunnan Normal University, Kunming 650092 (China); Ji, X.; Yin, F.; Xu, L. [Solar Energy Research Institute, Yunnan Normal University, 650092 Kunming (China)

    2011-06-15

    Research highlights: {yields} A 2 m{sup 2} Trough Concentrating Photovoltaic/Thermal (TCPV/T) system is built, a single crystalline silicon solar cell array, a polycrystalline silicon cell array, a Super cell array and a GaAs cell array are respectively used in the experiments. {yields} Another 10 m{sup 2} TCPV/T system using the GaAs cell array and a concentrating silicon cell array are also constructed and characterized. {yields} The economic performance analysis show the electricity generating cost of the TCPV/T system with the concentrating silicon cell array can catch up with flat-plate PV system. -- Abstract: The electrical and thermal performance of a 2 m{sup 2} Trough Concentrating Photovoltaic/Thermal (TCPV/T) system with an energy flux ratio 10.27 are characterized by experiments. A single crystalline silicon solar cell array, a polycrystalline silicon cell array, a Super cell array and a GaAs cell array are respectively used in the experiments. The experimental results show that the electrical performance of the system with the GaAs cell array is better than that of crystal silicon solar cell arrays. The superior output performance of the GaAs cell array mainly benefits from its lower series resistance. But the thermal performances of the system using the single crystal silicon solar cell array and the polycrystalline silicon solar cell array are better. It results from the widths of the two types of cells in the system close to that of the focal line. Another 10 m{sup 2} TCPV/T system with an energy flux ratio of 20 using the GaAs cell array and a concentrating silicon cell array are also constructed and characterized. The experimental results indicate that the photoelectric efficiency of the GaAs cell array is 23.83%, and the instantaneous electrical efficiency and thermal efficiency of the system are 9.88% and 49.84% respectively. While the instantaneous electrical efficiency and thermal efficiency of the system using the low-cost concentrating

  11. The performance analysis of the Trough Concentrating Solar Photovoltaic/Thermal system

    International Nuclear Information System (INIS)

    Li, M.; Li, G.L.; Ji, X.; Yin, F.; Xu, L.

    2011-01-01

    Research highlights: → A 2 m 2 Trough Concentrating Photovoltaic/Thermal (TCPV/T) system is built, a single crystalline silicon solar cell array, a polycrystalline silicon cell array, a Super cell array and a GaAs cell array are respectively used in the experiments. → Another 10 m 2 TCPV/T system using the GaAs cell array and a concentrating silicon cell array are also constructed and characterized. → The economic performance analysis show the electricity generating cost of the TCPV/T system with the concentrating silicon cell array can catch up with flat-plate PV system. -- Abstract: The electrical and thermal performance of a 2 m 2 Trough Concentrating Photovoltaic/Thermal (TCPV/T) system with an energy flux ratio 10.27 are characterized by experiments. A single crystalline silicon solar cell array, a polycrystalline silicon cell array, a Super cell array and a GaAs cell array are respectively used in the experiments. The experimental results show that the electrical performance of the system with the GaAs cell array is better than that of crystal silicon solar cell arrays. The superior output performance of the GaAs cell array mainly benefits from its lower series resistance. But the thermal performances of the system using the single crystal silicon solar cell array and the polycrystalline silicon solar cell array are better. It results from the widths of the two types of cells in the system close to that of the focal line. Another 10 m 2 TCPV/T system with an energy flux ratio of 20 using the GaAs cell array and a concentrating silicon cell array are also constructed and characterized. The experimental results indicate that the photoelectric efficiency of the GaAs cell array is 23.83%, and the instantaneous electrical efficiency and thermal efficiency of the system are 9.88% and 49.84% respectively. While the instantaneous electrical efficiency and thermal efficiency of the system using the low-cost concentrating silicon cell array are 7.51% and 42

  12. Investigation on the effect of thermal resistances on a highly concentrated photovoltaic-thermoelectric hybrid system

    International Nuclear Information System (INIS)

    Zhang, Jin; Xuan, Yimin

    2016-01-01

    Highlights: • The highly concentrated PV-TE hybrid system is studied. • The performances of different cooling systems are analyzed and compared. • Sandwiching a copper plate between the PV and TE can improve the efficiency. • Four thermal design principles of the system are proposed. - Abstract: A thermal analysis of a highly concentrated photovoltaic-thermoelectric (PV-TE) hybrid system is carried out in this paper. Both the output power and the temperature distribution in the hybrid system are calculated by means of a three-dimensional numerical model. Three possible approaches for designing the highly concentrated PV-TE hybrid system are presented by analyzing the thermal resistance of the whole system. First, the sensitivity analysis shows that the thermal resistance between the TE module and the environment has a more great effect on the output power than the thermal resistance between the PV and the TE. The influence of the natural convection and the radiation can be ignored for the highly concentrated PV-TE hybrid system. Second, it is necessary to sandwich a copper plate between the PV and the TE for decreasing the thermal resistance between the PV and the TE. The role of the copper plate is to improve the temperature uniformity. Third, decreasing the area of PV cells can improve the efficiency of the highly concentrated PV-TE hybrid system. It should be pointed out that decreasing the area of PV cells also increases the total thermal resistance, but the raise of the efficiency is caused by the reduction of the heat transfer rate of the system. Therefore, the principle of minimizing the total thermal resistance may not be suitable for optimizing the area of PV cells.

  13. Plankton And Heavy Metal Correlation From Commercial Vessels In Port Of Tanjung Emas Semarang

    Science.gov (United States)

    Tjahjono, Agus; Bambang, Aziz Nur; Anggoro, Sutrisno

    2018-02-01

    The commercial vessels activity have a big role to increase the flow of number of cargoes from a port to another port. However, the impact of these activities are the disposal of ballast water from port area to the destination port. The purpose of this research was to analyze the correlation of phytoplankton, zooplankton, and heavy metal which were contained inside the ballast water of commercial vessel towards in waters of the port of Tanjung Emas Semarang. The concentration of heavy metal either from commercial vessels or the waters in port area analyzed by Atomic Absorption Spectrophotometer (AAS). The result showed that the correlation of zooplankton and phytoplankton in the water ballast at commercial vessels have a medium correlation to zooplankton and phytoplankton in waters of Port of Tanjung Emas Semarang (PTES) were 48.9% and 58.3%. Correlation of heavy metal Cd, Zn, Cu, Zn and Pb in ballast water of commercial vessel toward each metal in waters of PTES area has a strong correlation in contribution were 76.7%, 75.6%, 71.4% and 73.8%. It showed us that the loading activity of commercial vessels in port are contributed towards the pollution in waters.

  14. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    OpenAIRE

    Qing-Hui WANG; Fang MU; Li-Feng WEI

    2014-01-01

    This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or conce...

  15. Design and Implementation of PLC-Based Automatic Sun tracking System for Parabolic Trough Solar Concentrator

    Directory of Open Access Journals (Sweden)

    Wang Jinping

    2016-01-01

    Full Text Available A sun-tracking system for parabolic trough solar concentrators (PTCs is a control system used to orient the concentrator toward the sun always, so that the maximum energy can be collected. The work presented here is a design and development of PLC based sun tracking control system for PTC. Sun tracking control system consists of a Programmable Logic Controller (PLC and a single axis hydraulic drives tracking control system. Hydraulic drives and the necessary tracking angle algorithm have been designed and developed to perform the technical tasks. A PLC unit was employed to control and monitor the mechanical movement of the PTC and to collect and store data related to the tracking angle of PTC. It is found that the tracking error of the system is less than 0.6°. Field experience shows that tracking algorithm act stable and reliable and suit for PTCs.

  16. The concentration gradient flow battery as electricity storage system: Technology potential and energy dissipation

    Science.gov (United States)

    van Egmond, W. J.; Saakes, M.; Porada, S.; Meuwissen, T.; Buisman, C. J. N.; Hamelers, H. V. M.

    2016-09-01

    Unlike traditional fossil fuel plants, the wind and the sun provide power only when the renewable resource is available. To accommodate large scale use of renewable energy sources for efficient power production and utilization, energy storage systems are necessary. Here, we introduce a scalable energy storage system which operates by performing cycles during which energy generated from renewable resource is first used to produce highly concentrated brine and diluate, followed up mixing these two solutions in order to generate power. In this work, we present theoretical results of the attainable energy density as function of salt type and concentration. A linearized Nernst-Planck model is used to describe water, salt and charge transport. We validate our model with experiments over wide range of sodium chloride concentrations (0.025-3 m) and current densities (-49 to +33 A m-2). We find that depending on current density, charge and discharge steps have significantly different thermodynamic efficiency. In addition, we show that at optimal current densities, mechanisms of energy dissipation change with salt concentration. We find the highest thermodynamic efficiency at low concentrate concentrations. When using salt concentrations above 1 m, water and co-ion transport contribute to high energy dissipation due to irreversible mixing.

  17. Single-port laparoscopic partial splenectomy: a case report.

    Science.gov (United States)

    Hong, Tae Ho; Lee, Sang Kuon; You, Young Kyoung; Kim, Jun Gi

    2010-10-01

    With the better understanding of the importance of the spleen as a primary organ of the human immune system, there has been an increased interest in performing the partial splenectomy for a number of indications such as nonparasitic cysts, benign tumors, staging of lymphomas, etc. Moreover, laparoscopic partial splenectomy has been gaining more interest as the recommended approach for benign splenic disorders to preserve the splenic function with very low recurrence rates. Meanwhile, many surgeons have attempted to reduce the number and size of the ports in laparoscopic surgery with the aim of inducing less parietal trauma and fewer scars. One of these efforts is single-port laparoscopic surgery, which is a rapidly evolving field all over the world. Here, we describe a feasible method of single-port laparoscopic partial splenectomy for treating a benign splenic cyst that was located in the upper medial aspect of the spleen.

  18. A Collaboration Service Model for a Global Port Cluster

    Directory of Open Access Journals (Sweden)

    Keith K.T. Toh

    2010-03-01

    Full Text Available The importance of port clusters to a global city may be viewed from a number of perspectives. The development of port clusters and economies of agglomeration and their contribution to a regional economy is underpinned by information and physical infrastructure that facilitates collaboration between business entities within the cluster. The maturity of technologies providing portals, web and middleware services provides an opportunity to push the boundaries of contemporary service reference models and service catalogues to what the authors propose to be "collaboration services". Servicing port clusters, portal engineers of the future must consider collaboration services to benefit a region. Particularly, service orchestration through a "public user portal" must gain better utilisation of publically owned infrastructure, to share knowledge and collaborate among organisations through information systems.

  19. Visits by nuclear powered warships to Australian ports. 2. ed.

    International Nuclear Information System (INIS)

    1987-09-01

    The aim of this document is to prescribe the conditions, procedures and responsibilities for the conduct of visits to Australia by United States and Royal Navy nuclear powered warships. The Commonwealth government requires contingency arrangements to be in place at all Australian ports visited and that there be the capability to undertake radiation monitoring of the port environment. Release mechanisms such as the failure or maloperation of radioactive waste control systems within the vessel, or an accident involving the reactor plant are dealt with in the plan

  20. Determination of the critical micelle concentration in simulations of surfactant systems.

    Science.gov (United States)

    Santos, Andrew P; Panagiotopoulos, Athanassios Z

    2016-01-28

    Alternative methods for determining the critical micelle concentration (cmc) are investigated using canonical and grand canonical Monte Carlo simulations of a lattice surfactant model. A common measure of the cmc is the "free" (unassociated) surfactant concentration in the presence of micellar aggregates. Many prior simulations of micellizing systems have observed a decrease in the free surfactant concentration with overall surfactant loading for both ionic and nonionic surfactants, contrary to theoretical expectations from mass-action models of aggregation. In the present study, we investigate a simple lattice nonionic surfactant model in implicit solvent, for which highly reproducible simulations are possible in both the canonical (NVT) and grand canonical (μVT) ensembles. We confirm the previously observed decrease of free surfactant concentration at higher overall loadings and propose an algorithm for the precise calculation of the excluded volume and effective concentration of unassociated surfactant molecules in the accessible volume of the solution. We find that the cmc can be obtained by correcting the free surfactant concentration for volume exclusion effects resulting from the presence of micellar aggregates. We also develop an improved method for determination of the cmc based on the maximum in curvature for the osmotic pressure curve determined from μVT simulations. Excellent agreement in cmc and other micellar properties between NVT and μVT simulations of different system sizes is observed. The methodological developments in this work are broadly applicable to simulations of aggregating systems using any type of surfactant model (atomistic/coarse grained) or solvent description (explicit/implicit).

  1. Importance of the evaluation of serum albumin concentration in postoperative period of patients submitted to major surgeries Importância da avaliação da concentração da albumina sérica no pós-operatório de operações de grande porte

    Directory of Open Access Journals (Sweden)

    Luiz Ronaldo Alberti

    2010-06-01

    Full Text Available BACKGROUND: The prevalence of protein-energy malnutrition in surgical patients is high, ranging from 10% to 54%. The correct assessment of the nutritional status of such patients is crucial since malnourishment is a risk factor for morbidity and mortality. AIM: To assess the effect of surgical trauma in serum albumin concentration during the immediate postoperative period of major surgeries. METHODS: The study was conducted on 100 randomly chosen adult patients submitted to elective major surgeries, classified according to sex, age and skin color. Blood samples for the determination of serum albumin concentrations were obtained on the days before and after the surgical procedure. RESULTS: There was a reduction in serum albumin from 3.72 ± 0.47 to 2.83 ± 0.71 g/dL (PRACIONAL: A prevalência de desnutrição energético-protéica em pacientes cirúrgicos é alta, variando entre 10% a 54%. A correta avaliação do estado nutricional desses pacientes é crucial uma vez que a desnutrição é um fator de risco para a morbidade e mortalidade. OBJETIVO: Avaliar o efeito do trauma cirúrgico na concentração sérica de albumina, durante o período pós-operatório imediato de operações de grande porte. MÉTODOS: O estudo foi conduzido em 100 pacientes escolhidos aleatoriamente adultos submetidos a procedimentos cirúrgicos eletivos de grande porte, classificados de acordo com sexo, idade e cor da pele. As amostras de sangue para a determinação da concentração sérica de albumina foram obtidas nos dias antes e após o procedimento cirúrgico. RESULTADOS: Houve diminuição da albumina sérica de 3,72 ± 0,47-2,83 ± 0,71 g / dL (P <0,0001, sem diferença de sexo ou cor da pele para operações de grande porte. Com relação à faixa etária, a maior queda da albumina foi observada entre os pacientes com idade superior a 65 anos, seguidos pelos pacientes mais jovens (<45 anos e, finalmente, pacientes com idade entre 45-65 anos. CONCLUSÃO: As

  2. PARTICULATE MATTER CONCENTRATION AND EMISSION FACTOR IN THREE DIFFERENT LAYING HEN HOUSING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Annamaria Costa

    2009-09-01

    Full Text Available The aim of this study was to evaluate PM10 concentration in three different laying hens houses (traditional battery cages with aerated open manure storage, aviary system and vertical tiered cages with manure belts with forced air drying and to evaluate particulate matter emission into atmosphere during one year of observation. Internal and external temperature and relative humidity, ventilation rate, PM10 concentration have been continuously monitored in order to evaluate particulate matter concentration changes during the day and the season and to define PM10 emission factors. PM10 concentration was corrected by gravimetric technique to lower measurements error. In the aviary system house, TSP and fine particulate matter (particles smaller than 2.5 micron concentration was measured. Average yearly PM10 concentration was remarkably higher in the aviary system house with 0.215 mg m-3 vs 108 mg m-3 for the ventilated belt house and vs 0.094 mg m-3 for the traditional battery cages house. In the Aviary system housing, TSP concentration was 0.444 mg m-3 and PM2.5 was 0.032 mg m-3, highlighting the existence of a severe working environment for men and animals. Recorded values for PM10 emission were 0.433 mg h-1 hen-1 for battery cages housing type, 0.081 mg h-1 hen-1 for ventilated belt cages house, values lower than those available in literature, while the aviary system housing type showed the highest PM10 emission (1.230 mg h-1 hen-1 with appreciable peaks during the morning, together with the increased animal activity and daily farmer operations, as feed administration, cleaning and droppings removal.

  3. A sensor-less methanol concentration control system based on feedback from the stack temperature

    International Nuclear Information System (INIS)

    An, Myung-Gi; Mehmood, Asad; Ha, Heung Yong

    2014-01-01

    Highlights: • A new sensor-less methanol control algorithm based on feedback from the stack temperature is developed. • Feasibility of the algorithm is tested using a DMFC system with a recirculating fuel loop. • The algorithm precisely controls the methanol concentration without the use of methanol sensors. • The sensor-less controller shortens the time that the DMFC system requires to go from start-up to steady-state. • This controller is effective in handling unexpected changes in the methanol concentration and stack temperature. - Abstract: A sensor-less methanol concentration control system based on feedback from the stack temperature (SLCCF) has been developed. The SLCCF algorithm is embedded into an in-house LabVIEW program that has been developed to control the methanol concentration in the feed of direct methanol fuel cells (DMFCs). This control method utilizes the close correlation between the stack temperature and the methanol concentration in the feed. Basically, the amounts of methanol to be supplied to the re-circulating feed stream are determined by estimating the methanol consumption rates under given operating conditions, which are then adjusted by a proportional–integral controller and supplied into the feed stream to maintain the stack temperature at a set value. The algorithm is designed to control the methanol concentration and the stack temperature for both start-up and normal operation processes. Feasibility tests with a 200 W-class DMFC system under various operating conditions confirm that the algorithm successfully maintains the methanol concentration in the feed as well as the stack temperature at set values, and the start-up time required for the DMFC system to reach steady-state operating conditions is reduced significantly compared with conventional sensor-less methods

  4. Modeling and performance analysis of a concentrated photovoltaic–thermoelectric hybrid power generation system

    International Nuclear Information System (INIS)

    Lamba, Ravita; Kaushik, S.C.

    2016-01-01

    Highlights: • Thermodynamic model of concentrated photovoltaic–thermoelectric system is analysed. • Thomson effect reduces the power output of PV, TE and hybrid PV–TEG system. • Effect of thermocouple number, irradiance, PV and TE current have been studied. • The optimum concentration ratio for maximum power output has been found out. • The overall efficiency and power output of hybrid PV–TEG system has been improved. - Abstract: In this study, a thermodynamic model for analysing the performance of a concentrated photovoltaic–thermoelectric generator (CPV–TEG) hybrid system including Thomson effect in conjunction with Seebeck, Joule and Fourier heat conduction effects has been developed and simulated in MATALB environment. The expressions for calculating the temperature of photovoltaic (PV) module, hot and cold sides of thermoelectric (TE) module are derived analytically as well. The effect of concentration ratio, number of thermocouples in TE module, solar irradiance, PV module current and TE module current on power output and efficiency of the PV, TEG and hybrid PV–TEG system have been studied. The optimum concentration ratio corresponding to maximum power output of the hybrid system has been found out. It has been observed that by considering Thomson effect in TEG module, the power output of the PV, TE and hybrid PV–TEG systems decreases and at C = 1 and 5, it reduces the power output of hybrid system by 0.7% and 4.78% respectively. The results of this study may provide basis for performance optimization of a practical irreversible CPV–TEG hybrid system.

  5. Standard Test Method for Electrical Performance of Concentrator Terrestrial Photovoltaic Modules and Systems Under Natural Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of photovoltaic concentrator modules and systems under natural sunlight using a normal incidence pyrheliometer. 1.2 The test method is limited to module assemblies and systems where the geometric concentration ratio specified by the manufacturer is greater than 5. 1.3 This test method applies to concentrators that use passive cooling where the cell temperature is related to the air temperature. 1.4 Measurements under a variety of conditions are allowed; results are reported under a select set of concentrator reporting conditions to facilitate comparison of results. 1.5 This test method applies only to concentrator terrestrial modules and systems. 1.6 This test method assumes that the module or system electrical performance characteristics do not change during the period of test. 1.7 The performance rating determined by this test method applies only at the period of the test, and implies no past or future performance level. 1.8...

  6. Tracer concentration curves and residence time analysis in technological flow systems. 2

    International Nuclear Information System (INIS)

    Pippel, W.

    1976-01-01

    Tracer concentration curves measured in flow systems by means of radioactive isotopes are treated as a two dimensional random process. Comparing them with the family distribution functions described in part I, it follows that only in case of ergodic behaviour of the system tracer curves can be considered as age distribution functions. The conception of ergodicity in residence time systems has been explained with the aid of a time function measurable by a special method of radioactive tracer technique and by the mean value of the residence time obtainable from this function. Furthermore, technological consequences in evaluating tracer concentration curves of real flow systems are discussed with respect to supposed ergodic or nonergodic behaviour. These considerations are of special importance for flow systems with temporary fluctuations in structure. (author)

  7. Exergy, Energy, and Dynamic Parameter Analysis of Indigenously Developed Low-Concentration Photovoltaic System

    OpenAIRE

    Pankaj Yadav; Brijesh Tripathi; Manoj Kumar

    2013-01-01

    Piecewise linear parabolic trough collector (PLPTC) is designed and developed to concentrate solar radiation on monocrystalline silicon based photovoltaic module. A theoretical model is used to perform electrical energy and exergy analysis of low-concentration photovoltaic (LCPV) system working under actual test conditions (ATC). The exergy efficiency of LCPV system is in the range from 5.1% to 4.82% with increasing rate of input exergy rate from 30.81 W to 96.12 W, when conce...

  8. Digital image monitoring to optimise safe port operation

    CSIR Research Space (South Africa)

    Phelp, D

    2008-11-01

    Full Text Available This paper describes a low cost video system ‘Harbour Watch’, which can be used to support safe port operations, especially in developing countries. Preset digital images are geo-referenced and then archived for later analysis to improve...

  9. Tempered Water Lower Port Connector Structural Analysis Verification

    International Nuclear Information System (INIS)

    CREA, B.A.

    2000-01-01

    Structural analysis of the lower port connection of the Tempered Water System of the Cold Vacuum Drying Facility was performed. Subsequent detailed design changes to enhance operability resulted in the need to re-evaluate the bases of the original analysis to verify its continued validity. This evaluation is contained in Appendix A of this report. The original evaluation is contained in Appendix B

  10. Outdoor Performance Comparison of Concentrator Photovoltaic and Flat Plate Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Hidaka Yoshihide

    2016-01-01

    Full Text Available Output characteristics of tracking type concentrator photovoltaic (CPV system, multi-crystalline silicon (mc-Si PV system, CIGS PV system, and amorphous silicon (a-Si PV system were analyzed in the data period of a year from August 2013 to July 2014. In this study, we analyzed the influence of environmental factors using average photon energy (APE and temperature of solar cell (Tcell. The characteristics of 14 kW CPV system, 50 kW mc-Si PV system, 60 kW CIGS PV system, 1.35 kW a-Si PV system were evaluated and compared. As a result, the output performance of CPV was highest between the four systems at the most frequent conditions in the outdoor environment.

  11. Hybrid photovoltaic-thermoelectric system for concentrated solar energy conversion: Experimental realization and modeling

    Science.gov (United States)

    Beeri, Ofer; Rotem, Oded; Hazan, Eden; Katz, Eugene A.; Braun, Avi; Gelbstein, Yaniv

    2015-09-01

    An experimental demonstration of the combined photovoltaic (PV) and thermoelectric conversion of concentrated sunlight (with concentration factor, X, up to ˜300) into electricity is presented. The hybrid system is based on a multi-junction PV cell and a thermoelectric generator (TEG). The latter increases the electric power of the system and dissipates some of the excessive heat. For X ≤ 200, the system's maximal efficiency, ˜32%, was mostly due to the contribution from the PV cell. With increasing X and system temperature, the PV cell's efficiency decreased while that of the TEG increased. Accordingly, the direct electrical contribution of the TEG started to dominate in the total system power, reaching ˜20% at X ≈ 290. Using a simple steady state finite element modeling, the cooling effect of the TEG on the hybrid system's efficiency was proved to be even more significant than its direct electrical contribution for high solar concentrations. As a result, the total efficiency contribution of the TEG reached ˜40% at X ≈ 200. This suggests a new system optimization concept that takes into account the PV cell's temperature dependence and the trade-off between the direct electrical generation and cooling capabilities of the TEG. It is shown that the hybrid system has a real potential to exceed 50% total efficiency by using more advanced PV cells and TE materials.

  12. Nitrogen oxides emission of mobile equipment in the port of Rotterdam. Consequences for nitrogen dioxide concentration, nitrogen deposition and a deduction of emission factors for container and bulk businesses; Stikstofoxidenemissies van mobiele werktuigen in de Rotterdamse haven. Gevolgen voor stikstofdioxide concentratie, stikstofdepositie, en een afleiding van emissiefactoren voor container- en droge bulk bedrijven

    Energy Technology Data Exchange (ETDEWEB)

    Okkerse, W J.H.; De Gier, C W

    2011-08-15

    In container terminals, dry bulk businesses and construction sites in the port of Rotterdam, the Netherlands, large masses of goods are transported by means of diesel-fuelled equipment every year. The combustion of diesel in this equipment results in emissions of nitrogen oxides (NOx) and particulate matter. This study has calculated the amounts of NOx emissions of the involved businesses based on detailed data on the composition of the equipment fleet of six representative storage and transshipment businesses. The resulting contribution to nitrogen oxide concentration at ground level and the nitrogen deposition have been calculated with the OPS model (Operational Priority Substances) [Dutch] Bij containerterminals, droge bulk bedrijven en bouwplaatsen in de Rotterdamse haven wordt jaarlijks een grote massa aan goederen getransporteerd met behulp van dieselaangedreven apparatuur. De verbranding van diesel in deze apparatuur zorgt voor de emissie van stikstofoxiden (NOx) en stof. In dit onderzoek zijn de NOx emissies van de betrokken bedrijven berekend op basis van gedetailleerde gegevens over de samenstelling van het werktuigenpark van zes representatieve op- en overslagbedrijven. De resulterende bijdrage aan de stikstofdioxide (NO2) concentratie op leefniveau en de stikstofdepositie is berekend met het OPS-model (Operationele Prioritaire Stoffen)

  13. Concentration-Induced Association in a Protein System Caused by a Highly Directional Patch Attraction.

    Science.gov (United States)

    Li, Weimin; Persson, Björn A; Lund, Mikael; Bergenholtz, Johan; Zackrisson Oskolkova, Malin

    2016-09-01

    Self-association of the protein lactoferrin is studied in solution using small-angle X-ray scattering techniques. Effective static structure factors have been shown to exhibit either a monotonic or a nonmonotonic dependence on protein concentration in the small wavevector limit, depending on salt concentration. The behavior correlates with a nonmonotonic dependence of the second virial coefficient on salt concentration, such that a maximum appears in the structure factor at a low protein concentration when the second virial coefficient is negative and close to a minimum. The results are interpreted in terms of an integral equation theory with explicit dimers, formulated by Wertheim, which provides a consistent framework able to explain the behavior in terms of a monomer-dimer equilibrium that appears because of a highly directional patch attraction. Short attraction ranges preclude trimer formation, which explains why the protein system behaves as if it were subject to a concentration-dependent isotropic protein-protein attraction. Superimposing an isotropic interaction, comprising screened Coulomb repulsion and van der Waals attraction, on the patch attraction allows for a semiquantitative modeling of the complete transition pathway from monomers in the dilute limit to monomer-dimer systems at somewhat higher protein concentrations.

  14. Long-term catheterization: current approaches in the diagnosis and treatment of port-related infections

    Directory of Open Access Journals (Sweden)

    Bustos C

    2014-02-01

    Full Text Available Cesar Bustos,1 Aitziber Aguinaga,1 Francisco Carmona-Torre,2 Jose Luis Del Pozo1,3 1Department of Clinical Microbiology, 2Department of Internal Medicine, 3Division of Infectious Diseases, Clinica Universidad de Navarra, Pamplona, Spain Abstract: Since the first description in 1982, totally implanted venous access ports have progressively improved patients' quality of life and medical assistance when a medical condition requires the use of long-term venous access. Currently, they are part of the standard medical care for oncohematologic patients. However, apart from mechanical and thrombotic complications, there are also complications associated with biofilm development inside the catheters. These biofilms increase the cost of medical assistance and extend hospitalization. The most frequently involved micro-organisms in these infections are gram-positive cocci. Many efforts have been made to understand biofilm formation within the lumen catheters, and to resolve catheter-related infection once it has been established. Apart from systemic antibiotic treatment, the use of local catheter treatment (ie, antibiotic lock technique is widely employed. Many different antimicrobial options have been tested, with different outcomes, in clinical and in in vitro assays. The stability of antibiotic concentration in the lock solution once instilled inside the catheter lumen remains unresolved. To prevent infection, it is mandatory to perform hand hygiene before catheter insertion and manipulation, and to disinfect catheter hubs, connectors, and injection ports before accessing the catheter. At present, there are still unresolved questions regarding the best antimicrobial agent for catheter-related bloodstream infection treatment and the duration of concentration stability of the antibiotic solution within the lumen of the port. Keywords: catheter-related infection, bacteremia, biofilm

  15. Diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream

    Science.gov (United States)

    Partridge, Jr., William P.; Jatana, Gurneesh Singh; Yoo, Ji Hyung; Parks, II, James E.

    2017-12-26

    A diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream is described. The system may include one or more probes that sample the fluid stream spatially, temporally and over ranges of pressure and temperature. Laser light sources are directed down pitch optical cables, through a lens and to a mirror, where the light sources are reflected back, through the lens to catch optical cables. The light travels through the catch optical cables to detectors, which provide electrical signals to a processer. The processer utilizes the signals to calculate CO.sub.2 concentration based on the temperatures derived from H.sub.2O vapor concentration. A probe for sampling CO.sub.2 and H.sub.2O vapor concentrations is also disclosed. Various mechanical features interact together to ensure the pitch and catch optical cables are properly aligned with the lens during assembly and use.

  16. Investigation of sediment transport and optimization of dredging operations in Indian ports using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.

    2012-01-01

    India has a long coastline of about 7,515 km and there are twelve major ports situated on the coastline. Out of them, six are situated on the West Coast whereas other six are situated on the East Coast. In addition to this, there are more than 140 minor ports and other marine establishments situated along the coastline. Each port and marine project has a navigation channel and depth of this navigation channel needs to be maintained to a level of at least 12-15 meters for smooth sailing of ships. Sediments continuously move along the coast due to alongshore currents generated by the waves and tides; and get deposited in navigation channels. For maintaining the required depth of the channels, the dredging operation is carried out. throughout the year or as and when required. Development of a new port or harbour also involves huge capital dredging. The dredged sediments generated during maintenance or capital dredging needs to be dumped at a suitable location, so that it does not find its way back to the channel and obstruct sailing of ships. Moreover the selected site should be such that the turn around time of the dredger is kept minimum to economize the dredging operation. In order to meet the above requirements, the knowledge of transport parameters such as the general direction of movement, extent of lateral and longitudinal movement, transport velocity, transport thickness and bed load movement rate is required. Radiotracer techniques are commonly used to investigate sediment transport on seabed and evaluate the suitability of the proposed dumping sites. Scandium-46 (half-life: 84 days, Gamma energies: 0.89 MeV (100%), 1.12 MeV (100%)) in the form of scandium glass powder is the most suitable radiotracer for tracing sediments on seabed. The activity used in an investigation ranges from 75-300 GBq (2-8 Ci). The suitably prepared particulate radiotracer is injected on seabed at the proposed site using a specially designed injection system and its movement is

  17. Development of a 10 Hz measurement system for atmospheric aerosol concentration

    International Nuclear Information System (INIS)

    Bouarouri, Assia

    2014-01-01

    The goal is to develop an aerosol charger based on a corona discharge for atmospheric concentration measurements (10 3 -10 5 cm -3 ) within a response time of 100 ms. Two ion sources, point-to-hole and wire-to-slit have been characterized. The increase of the ion flow in the post-discharge by EHD ion confinement in both the discharge gap and the hole has been shown. At first, using an experimental survey driven in two mixing configurations, concentric and face-to-face, we have confirmed the aerosol diffusion charging law which depends on aerosol diameter and N i .t product, with N i , the ions concentration and t, the charging time. Thus, the originality of this charger relies on the very high heterogeneity of unipolar ion densities (N i 0 ≥10 9 cm -3 ) required to compensate the charging time of 50 ms. In these conditions, we have shown that aerosol diameter and the charging dynamic (which depends also on the diameter) control the aerosol trajectory. The chargers have, next, been compared in different operating conditions, mainly in terms of the maximal charging and the minimal losses. In the chosen charger (point-to-hole ion source and concentric mixing), the relations charge/mobility and losses according to diameter have been characterized. We have also shown the linearity of the charged particles current with the aerosol concentration which allows the current-concentration data inversion. The preliminary measurement system composed by the charger, the separator and the particle current measurements, satisfies the objectives of the study in terms of the concentration detection limit (10 3 cm -3 ) and the response time (100 ms). We have thus shown the feasibility of an atmospheric aerosol concentration measurement system at 10 Hz using a corona discharge charger provided that the separation power is improved. Furthermore, knowing that aerosol losses are negligible and the lower limit of the partial charging, the developed charger is adaptable with other

  18. Knowledge construction about port performance evaluation: An international literature analysis

    Directory of Open Access Journals (Sweden)

    Karine Somensi

    2017-10-01

    Full Text Available Purpose: This study aims at identifying and analyzing the characteristics of international scientific research that address the literature fragment referring to the Port Performance Evaluation to identify the existence of theoretical alignment of Performance Evaluation notion, as an area of knowledge, with practical area stage, the Port Performance Evaluation. Design/Methodology/Approach: The approach the problem, this paper makes use of qualitative research, since it analyzes the Bibliographical Portfolio characteristics related to the Performance Evaluation Port. The strategy adopted was action research where the authors through their analysis and interpretation made the selection of the  Bibliographical Portfolio. Findings: From the analyzed literature fragment it was possible to identify some misalignment between what has been pointed out in the literature regarding the management practices in the port sector. This discrepancy refers to the management practices that are ignored by port managers, which implies the loss of opportunities and may even come to jeopardize the organization's performance. Research limitations/implications: The literature search was restricted to articles written in the English language, published in indexed scientific journals in the selected databases (ii the restriction by the time limit of articles published after the year 2000; (iii the generation of knowledge based on the characteristics selected by the researchers and (iv the analysis of BP articles regarding the  by the judgment and interpretation of this research authors. It is suggested for future work the expanding this research to other databases, other languages, other features, and continuity of this investigation with the development of "systemic analysis' and 'identifying research opportunities' stages through ProKnow-C. Originality/value: Although two similar works have been developed in the same area of research in 2015, the results achieved have

  19. Robust and optimal control a two-port framework approach

    CERN Document Server

    Tsai, Mi-Ching

    2014-01-01

    A Two-port Framework for Robust and Optimal Control introduces an alternative approach to robust and optimal controller synthesis procedures for linear, time-invariant systems, based on the two-port system widespread in electrical engineering. The novel use of the two-port system in this context allows straightforward engineering-oriented solution-finding procedures to be developed, requiring no mathematics beyond linear algebra. A chain-scattering description provides a unified framework for constructing the stabilizing controller set and for synthesizing H2 optimal and H∞ sub-optimal controllers. Simple yet illustrative examples explain each step. A Two-port Framework for Robust and Optimal Control  features: ·         a hands-on, tutorial-style presentation giving the reader the opportunity to repeat the designs presented and easily to modify them for their own programs; ·         an abundance of examples illustrating the most important steps in robust and optimal design; and ·   �...

  20. Study on the pelletizing of sulfate residue with magnetite concentrate in grate-kiln system

    Directory of Open Access Journals (Sweden)

    Shufeng Y.

    2010-01-01

    Full Text Available The experiment on the feasibility of pelletizing with magnetite concentrate and the wasted sulfate residue was carried out, to research the performance of pellet in grate-kiln system and simulate the grate-kiln pelletizing process in the micro-pellet roasting simulation system in laboratory, and the process experiments on preheating and roasting sections were conducted. The results show that in order to obtain pellet with good performance and the magnetite concentrate should be over 20 in mass percent, the suitable pelletizing time is about 10 min and moisture is around 12.5%. Also, according to the process parameters of drying and preheating sections obtained from experiment, it will be successful to use magnetite concentrate and the wasted sulfate residue for pelletizing, which exploits a new way for the use of sulfate residue.

  1. Ventilation systems as an effective tool for control of radon daughter concentration in mines

    International Nuclear Information System (INIS)

    Dory, A.B.

    1981-10-01

    Introduced with a brief discussion of the key role of ventilation in controlling mine atmospheres, the effects of the design of the ventilation system on the control of radon daughter concentrations are illustrated with specific reference to Alcan's Director Mine, St-Lawrence, Nfld. (This fluorspar mine was found to have high radon concentrations due to mine water bringing in dissolved radon.) After a discussion of the health physics history of the mine, the various phases of the ventilation system design and the general results are detailed. The author draws some conclusions having general application to the design of any mine with a radon or thoron daughter concentration. These include minimizing the 'age' of the air; the need for continuous ventilation in all areas; the value of remote control and monitoring; and the benefits of mine pressurization

  2. Development of Fresnel-based Concentrated Photovoltaic (CPV System with Uniform Irradiance

    Directory of Open Access Journals (Sweden)

    Irfan Ullah

    2014-12-01

    Full Text Available Different designs have been presented to achieve high concentration and uniformity for the concentrated photovoltaic (CPV system. Most of the designs have issues of low efficiency in terms of irradiance uniformity. To this end, we present a design methodology to increase irradiance uniformity over solar cell. The system consists of an eight-fold Fresnel lens as a primary optical element (POE and an optical lens, which consists of eight parts, as a secondary optical element (SOE. Sunlight is focused through the POE and then light is spread over cell through the SOE. In the design, maximum sunlight is passed over cell by minimizing losses. Results have shown that the proposed CPV design gives good irradiance uniformity. The concentration module based on this novel design is a promising option for the development of a cost-effective photovoltaic solar energy generation.

  3. The Challenges of Malaysian Dry Ports Development

    Directory of Open Access Journals (Sweden)

    Jagan Jeevan

    2015-03-01

    Full Text Available This paper examines the functions and challenges of dry ports development in Malaysia through 11 face-to-face interviews with dry port stakeholders. The findings reveal that Malaysian dry ports are developed to accelerate national and international business, to activate intermodalism in the nation, to promote regional economic development and to enhance seaport competitiveness. Malaysian dry ports perform the function of transport and logistics, information processing, seaports and value-added services. Challenges facing Malaysian dry ports include insufficient railway tracks, unorganized container planning on the rail deck, highly dependent on single mode of transportation, poor recognition from the seaport community, and competition from localized seaports. This paper further indicates strategies for coping with these challenges and identifies future opportunities for Malaysian dry ports development.

  4. SHAPE EFFECT OF ANNULAR CONCENTRATOR IN ULTRASONIC SYSTEM ON AMPLIFICATION FACTOR OF VIBRATIONS AMPLITUDE

    Directory of Open Access Journals (Sweden)

    D. A. Stepanenko

    2016-01-01

    Full Text Available The paper contains a theoretical underpinning on creation of ultrasonic vibration concentrators based on annular elastic elements with non-circular (ellipse-like eccentric shape of internal contour. Shape of internal contour in polar coordinates is described by Fourier series relative to angular coordinate that consists of a constant term and first and second harmonics. An effect of geometric parameters of the concentrator on amplification factor and natural vibration frequencies has been investigated with the help of a finite element method. The paper reveals the possibility to control an amplification factor of annular concentrators while varying eccentricity of internal contour and mean value of cross-section thickness. The amplification factor satisfies a condition K < N, where N is thickness ratio of amplifier input and output sections, and it is decreasing with increase of vibration mode order. The similar condition has been satisfied for conical bar concentrator with the difference that in the case of bar concentrators an amplification is ensured due to variation of diameter and N will represent ratio of diameters. It has been proved that modification of internal contour shape makes it possible to carry out a wide-band tuning of natural frequencies of concentrator vibrations without alteration of its overall dimensions and substantial change of amplification factor, which is important for frequency matching of the concentrator and ultrasonic vibratory system. Advantages of the proposed concentrators include simplicity of design and manufacturing, small overall dimensions, possibility for natural frequency tuning by means of static load variation. The developed concentrators can find their application in ultrasonic devices and instruments for technological and medical purposes.

  5. Dynamics of the stochastic low concentration trimolecular oscillatory chemical system with jumps

    Science.gov (United States)

    Wei, Yongchang; Yang, Qigui

    2018-06-01

    This paper is devoted to discern long time dynamics through the stochastic low concentration trimolecular oscillatory chemical system with jumps. By Lyapunov technique, this system is proved to have a unique global positive solution, and the asymptotic stability in mean square of such model is further established. Moreover, the existence of random attractor and Lyapunov exponents are obtained for the stochastic homeomorphism flow generated by the corresponding global positive solution. And some numerical simulations are given to illustrate the presented results.

  6. Performance Evaluation of a Solar Adsorption Refrigeration System with a Wing Type Compound Parabolic Concentrator

    OpenAIRE

    Umair, Muhammad; Akisawa, Atsushi; Ueda, Yuki

    2014-01-01

    Simulation study of a solar adsorption refrigeration system using a wing type compound parabolic concentrator (CPC) is presented. The system consists of the wing type collector set at optimum angles, adsorption bed, a condenser and a refrigerator. The wing type collector captures the solar energy efficiently in the morning and afternoon and provides the effective temperature for a longer period of time compared to that achieved by a linear collector. The objectives of the study were to evalua...

  7. Experimental validation of a heat transfer model for concentrating photovoltaic system

    International Nuclear Information System (INIS)

    Sendhil Kumar, Natarajan; Matty, Katz; Rita, Ebner; Simon, Weingaertner; Ortrun, Aßländer; Alex, Cole; Roland, Wertz; Tim, Giesen; Tapas Kumar, Mallick

    2012-01-01

    In this paper, a three dimensional heat transfer model is presented for a novel concentrating photovoltaic design for Active Solar Panel Initiative System (ASPIS). The concentration ratio of two systems (early and integrated prototype) are 5× and 10× respectively, designed for roof-top integrated Photovoltaic systems. ANSYS 12.1, CFX package was effectively used to predict the temperatures of the components of the both ASPIS systems at various boundary conditions. The predicted component temperatures of an early prototype were compared with experimental results of ASPIS, which were carried out in Solecta – Israel and at the Austrian Institute of Technology (AIT) – Austria. It was observed that the solar cell and lens temperature prediction shows good agreement with Solecta measurements. The minimum and maximum deviation of 3.8% and 17.9% were observed between numerical and Solecta measurements and the maximum deviations of 16.9% were observed between modeling and AIT measurements. Thus, the developed validated thermal model enables to predict the component temperatures for concentrating photovoltaic systems. - Highlights: ► Experimentally validated heat transfer model for concentrating Photovoltaic system developed. ► Predictions of solar cell temperatures for parallactic tracking CPV system for roof integration. ► The ASPIS module contains 2 mm wide 216 solar cells manufactured based on SATURN technology. ► A solar cell temperature of 44 °C was predicted for solar radiation intensity was 1000 W/m 2 and ambient temperature was 20 °C. ► Average deviation was 6% and enabled to predict temperature of any CPV system.

  8. Concentration and Diversity of Availability and Use in Information Systems: A Positive Reinforcement Model.

    Science.gov (United States)

    Rousseau, Ronald

    1992-01-01

    Proposes a mathematical model to explain the observed concentration or diversity of nominal classes in information retrieval systems. The Lorenz Curve is discussed, Information Production Process (IPP) is explained, and a heuristic explanation of circumstances in which the model might be used is offered. (30 references) (LRW)

  9. Computational fluid dynamics simulations of flow and concentration polarization in forward osmosis membrane systems

    DEFF Research Database (Denmark)

    Gruber, M.F.; Johnson, C.J.; Tang, C.Y.

    2011-01-01

    is inspired by previously published CFD models for pressure-driven systems and the general analytical theory for flux modeling in asymmetric membranes. Simulations reveal a non-negligible external concentration polarization on the porous support, even when accounting for high cross-flow velocity and slip...

  10. Retrogradation of concentrated starch systems : mechanism and consequences for product properties

    NARCIS (Netherlands)

    Keetels, C.J.A.M.

    1995-01-01

    The mechanical properties of concentrated starch + water systems were studied during heating, cooling and storage. Methods used were a small-amplitude dynamic rheological test and compression between parallel plates. The mechanical properties were related to the structure of the gels.

  11. Testing of a uranium downhole logging system to measure in-situ plutonium concentrations in sediments

    International Nuclear Information System (INIS)

    Kasper, R.B.; Kay, M.A.; Bruns, L.E.; Stokes, J.A.; Steinman, D.K.; Adams, J.

    1980-11-01

    A prototype urainium borehole logging system, developed for uranium exploration, was modified for Pu assay and testing at the site. It uses the delayed fission neutron (DFN) method. It was tested in a retired Pu facility, the 216-Z-1A Crib. General agreement between laboratory determined Pu concentrations in sediment samples and neutron flux measurements was found for the relative distribution with depth

  12. Port pricing : principles, structure and models

    OpenAIRE

    Meersman, Hilde; Strandenes, Siri Pettersen; Van de Voorde, Eddy

    2014-01-01

    Price level and price transparency are input to shippers’ choice of supply chain and transport mode. In this paper, we analyse current port pricing structures in the light of the pricing literature and consider opportunities for improvement. We present a detailed overview of pricing criteria, who sets prices and who ultimately foots the bill for port-of-call charges, cargo-handling fees and congestion charges. Current port pricing practice is based on a rather linear structure and fails to in...

  13. Efficiency analysis of container ports and terminals

    OpenAIRE

    Liu, Q.

    2010-01-01

    In the past two decades the steady growth of seaborne trade has resulted in the increase of container ships, container ports and their terminals. The structure of the shipping market is, moreover, continuously evolving. On the carrier side, shipping companies form consortia and alliances; on the port side, global terminal operators and dedicated container terminals are emerging. The aim of this research is to evaluate the efficiency of container ports and terminals and to study...

  14. Port Sunlight, essai architectural et social

    OpenAIRE

    Machet, Laurence

    2017-01-01

    The purpose of this article is to examine the city of Port Sunlight, its history, design and originality. Created by William Lever in 1888 in order to house his newly-built soap factory, Port Sunlight is part of the numerous “factory villages” built in the wake of the industrial revolution according to philanthropic and utilitarian principles. But this article intends to show that Port Sunlight differs from other factory towns. Its careful design, elaborate architecture and public facilities ...

  15. PORT SECURITY-Threats and Vulnerabilities

    OpenAIRE

    Kusi, Bernard

    2015-01-01

    The main objective of this thesis is to identify the threats and the vulnerabilities concerning Takoradi port, and finally recommend measure to overcome the identified threats and vul-nerabilities. Various categories of potential threats and vulnerabilities have been studied throughout the literature review. However, because each port presents a unique sets of threats and vulnerabilities, there was a need to look critically into how Takoradi port operations are being conducted in other to ide...

  16. Investigation of Solar Hybrid Electric/Thermal System with Radiation Concentrator and Thermoelectric Generator

    Directory of Open Access Journals (Sweden)

    Edgar Arturo Chávez Urbiola

    2013-01-01

    Full Text Available An experimental study of a solar-concentrating system based on thermoelectric generators (TEGs was performed. The system included an electrical generating unit with 6 serially connected TEGs using a traditional semiconductor material, Bi2Te3, which was illuminated by concentrated solar radiation on one side and cooled by running water on the other side. A sun-tracking concentrator with a mosaic set of mirrors was used; its orientation towards the sun was achieved with two pairs of radiation sensors, a differential amplifier, and two servomotors. The hot side of the TEGs at midday has a temperature of around 200°C, and the cold side is approximately 50°C. The thermosiphon cooling system was designed to absorb the heat passing through the TEGs and provide optimal working conditions. The system generates 20 W of electrical energy and 200 W of thermal energy stored in water with a temperature of around 50°C. The hybrid system studied can be considered as an alternative to photovoltaic/thermal systems, especially in countries with abundant solar radiation, such as Mexico, China, and India.

  17. Concentration dependence of surface properties and molar volume of multicomponent system indium-tin-lead-bismuth

    Energy Technology Data Exchange (ETDEWEB)

    Dadashev, R; Kutuev, R [Complex Science Research Institute of the Science Academy of the Chechen Republic, 21 Staropromisl. shosse, Grozny 364096 (Russian Federation); Elimkhanov, D [Science Academy of the Chechen Republic (Russian Federation)], E-mail: edzhabrail@mail.ru

    2008-02-15

    The results of an experimental research of surface properties of the four-component system indium-tin-lead-bismuth are presented. The researches under discussion were carried out in a combined device in which the surface tension ({sigma}) is measured by the method of maximum pressure in a drop, and density ({rho}) is measured by advanced aerometry. Measurement errors are 0.7 % for surface tension measurement, and 0.2 % for density measurement. The study of the concentration dependence of {sigma} in this system has revealed the influence of the third and fourth components upon the characteristics of surface tension isotherms of the binary system indium-tin. It was found out that with an increase in the content of the third and fourth components the depth of the minimum on the surface tension isotherms of the indium-tin system {sigma} decreases. On the basis of the concentration dependence of the phenomenon of concentration bufferity is revealed. It is shown that despite the complex character, isotherms of {sigma} on beam sections of a multicomponent system do not contain qualitatively new features in comparison with the isotherms of these properties in lateral binary systems.

  18. US Army Corps of Engineers Ports, Geographic WGS84, BTS (2006) [usace_port_BTS_2006

    Data.gov (United States)

    Louisiana Geographic Information Center — Contains physical information on commercial facilities at the principal U.S. Coastal, Great Lakes and Inland Ports. The data consists of listings of port area's...

  19. THE Port - hackathon at CERN

    CERN Multimedia

    CERN. Geneva; KNAEPPER, Ines; SILVA DE SOUSA, Bruno

    2014-01-01

    THE Port association combines creative minds from CERN and non-profit organisations in interdisciplinary teams to work on humanitarian technology related benefits to society. Our interdisciplinary teams of handpicked individuals chosen for their field-leading expertise and innovative mind combine humanitarian questions with state of the art science, cutting-edge technology and endless fantasy. We aim to impact the future by fusion of today’s real life problems analysis and vision of scientific evolution of the next decades. This forces us to develop concepts and solutions for the future - hungry to use our expertise in challenges of new fields.

  20. Port virtual addressing for PC

    International Nuclear Information System (INIS)

    Bolanos, L.; Arista, E.; Osorio Deliz, J.F.

    1997-01-01

    Instruments for nuclear signal measurements based on add-on card for a personal computer (PC) are designed often. Then one faces the problem of the addressing of data input/output devices which show an integration level or intelligence that makes the use of several port address indispensable, and these are limited in the PC. The virtual addressing offers the advantage of the occupation of few addresses to accede to many of these devices. The principles of this technique and the appliances of a solution in radiometric in a radiometric card based on programmed logic are discussed in this paper

  1. POLICY PORT IN LATIN AMERICA

    Directory of Open Access Journals (Sweden)

    María Victoria Flores

    2012-07-01

    Full Text Available This work achieves a contextual approach the port services market in Latin America, from the document review the legal framework and jurisprudence. It observes and evaluates the phenomenon under study, establishing a correlation between the grant in the shape of the free supply and demand for services and operating in a market of few suppliers, resulting in national legislation and concession contracts defending a free market and on the other hand, case law on market practice indicating that there is no free market to defend.

  2. Experimental study on a new solar boiling water system with holistic track solar funnel concentrator

    International Nuclear Information System (INIS)

    Xiaodi, Xue; Hongfei, Zheng; Kaiyan, He; Zhili, Chen; Tao, Tao; Guo, Xie

    2010-01-01

    A new solar boiling water system with conventional vacuum-tube solar collector as primary heater and the holistic solar funnel concentrator as secondary heater had been designed. In this paper, the system was measured out door and its performance was analyzed. The configuration and operation principle of the system are described. Variations of the boiled water yield, the temperature of the stove and the solar irradiance with local time have been measured. Main factors affecting the system performance have been analyzed. The experimental results indicate that the system produced large amount of boiled water. And the performance of the system has been found closely related to the solar radiance. When the solar radiance is above 600 W/m 2 , the boiled water yield rate of the system has reached 20 kg/h and its total energy efficiency has exceeded 40%.

  3. Testing and Analysis of Sensor Ports

    Science.gov (United States)

    Zhang, M.; Frendi, A.; Thompson, W.; Casiano, M. J.

    2016-01-01

    This Technical Publication summarizes the work focused on the testing and analysis of sensor ports. The tasks under this contract were divided into three areas: (1) Development of an Analytical Model, (2) Conducting a Set of Experiments, and (3) Obtaining Computational Solutions. Results from the experiment using both short and long sensor ports were obtained using harmonic, random, and frequency sweep plane acoustic waves. An amplification factor of the pressure signal between the port inlet and the back of the port is obtained and compared to models. Comparisons of model and experimental results showed very good agreement.

  4. DEA Window Analysis for Measuring Port Efficiencies in Serbia

    Directory of Open Access Journals (Sweden)

    Danijela Pjevčević

    2012-01-01

    Full Text Available The aim of the paper is to apply Data Envelopment Analysis (DEA method in measuring and analyzing the efficiencies of ports on the river Danube. DEA window analysis is used to determine the efficiency of ports and to observe the possibility of changes in the port efficiency over time. A study is conducted to evaluate the efficiencies of ports on the territory of Serbia in order to identify the sources of inefficiencies and formulate proposals for improving the services of those ports and their operations through a four-year window analysis with port efficiency trends and average efficiencies. The progress is made in the measurement of port efficiency in relation to port productive activities - total area of warehouses, quay length, number of cranes and port throughput, for the Serbian river ports. Keywords: river ports, total area of warehouses, quay length, number of cranes, port throughput, port efficiency, DEA window analysis

  5. Photovoltaic Systems with and without Radiation Concentrators for Temperate and Tropical Regions

    Directory of Open Access Journals (Sweden)

    Vania Reis de Souza Sant’Anna

    2015-11-01

    Full Text Available The industrial development of solar photovoltaic technology has attracted investors and influenced governments to establish public policies for the sector. The present research consisted of studying, building and testing low concentration solar radiation systems for photovoltaic energy conversion. The study used optical nonimaging parameters for the V-trough type radiation concentrator constructed of anodized aluminum, to reflect and to cool. Designed to concentrate radiation by about two times and consisting of a set of photovoltaic modules connected in parallel, they were modeled in the Laboratory of Energy Area in the Department of Agricultural Engineering of the Federal University of Vicosa, Brazil, at the coordinates 20°45′14′′ S latitude, 42°52′53′′ W longitude and altitude 648.74 m. They were installed to the geographic North, with the same slope as the local latitude. For comparative analysis, it was determined the electrical characteristics for evaluation of the prototype’s performance with and without radiation concentration, the final productivity for cities in tropical and temperate regions and economic analysis for the system. It was concluded that the prototypes allowed for a gain of energy with concentration, about 31.3% more, and therefore a productivity gain for the analyzed cities in, kWh·kWp−1.

  6. Critical micelle concentration of surfactants in aqueous buffered and unbuffered systems

    International Nuclear Information System (INIS)

    Fuguet, Elisabet; Rafols, Clara; Roses, Marti; Bosch, Elisabeth

    2005-01-01

    Critical micelle concentration (CMC) of sodium dodecyl sulphate (SDS), lithium perfluorooctanesulfonate (LPFOS), hexadecyltrimethylammonium bromide (HTAB), tetradecyltrimethylammonium bromide (TTAB), and sodium cholate (SC), surfactants commonly used as pseudostationary phases in micellar electrokinetic chromatography (MEKC), have been determined by means of three different methods: MEKC, spectrophotometry, and conductometry. Determinations have been performed in water, and also in different concentrations of phosphate buffer at pH 7.0. CMC values ranging from 8.08 (water) to 1.99 (50 mM phosphate buffer) mM for SDS, from 7.16 (water) to 2,81 (30 mM phosphate buffer) mM for LPFOS, from 3.77 (water) to 1.93 (20 mM phosphate buffer) mM for TTAB, from 0.91 (water) to ∼0.34 (20 mM phosphate buffer) for HTAB, and around 13 mM (20 mM phosphate buffer) for SC, are obtained. The effect of the electrolyte concentration on the CMC, as well as the linear relationship between the electrolyte counter-ion concentration and the CMC are discussed. This linear relationship provides an easy way for users to estimate the CMC of a MEKC system, at a given electrolyte concentration. A comparison between experimental methods, as well as a discussion about the suitability of a given method for the determination of the CMC for a given surfactant system is also provided

  7. Perancangan Miniatur Traffic Light Dengan Mempergunakan Pengendali Port Paralel

    Directory of Open Access Journals (Sweden)

    Eka Wahyudi

    2012-05-01

    Full Text Available Port paralel tentunya sudah tidak asing lagi dalam dunia komputer. Hal tersebut disebabkan karena port paralel merupakan sarana komunikasi yang terdapat pada Personal Computer (PC. Dengan memanfaatkan port tersebut, saat ini komputer juga dapat dipergunakan untuk keperluan pengontrolan/pengendalian rangkaian listrik dengan memanfaatkan port paralel (port printer. Port paralel memiliki kecepatan transfer data yang lebih cepat apabila dibandingkan dengan port serial, maka dari itu port paralel lebih banyak dipergunakan untuk pengendalian nyala lampu (LED. Dengan memanfaatkan bantuan software Saraf Listrik versi 1.01, maka port paralel dapat menjadi alternatif baru untuk pengendalian traffic light.

  8. Strontium concentrations in corrosion products from residential drinking water distribution systems.

    Science.gov (United States)

    Gerke, Tammie L; Little, Brenda J; Luxton, Todd P; Scheckel, Kirk G; Maynard, J Barry

    2013-05-21

    The United States Environmental Protection Agency (US EPA) will require some U.S. drinking water distribution systems (DWDS) to monitor nonradioactive strontium (Sr(2+)) in drinking water in 2013. Iron corrosion products from four DWDS were examined to assess the potential for Sr(2+) binding and release. Average Sr(2+) concentrations in the outermost layer of the corrosion products ranged from 3 to 54 mg kg(-1) and the Sr(2+) drinking water concentrations were all ≤0.3 mg L(-1). Micro-X-ray adsorption near edge structure spectroscopy and linear combination fitting determined that Sr(2+) was principally associated with CaCO3. Sr(2+) was also detected as a surface complex associated with α-FeOOH. Iron particulates deposited on a filter inside a home had an average Sr(2+) concentration of 40.3 mg kg(-1) and the associated drinking water at a tap was 210 μg L(-1). The data suggest that elevated Sr(2+) concentrations may be associated with iron corrosion products that, if disturbed, could increase Sr(2+) concentrations above the 0.3 μg L(-1) US EPA reporting threshold. Disassociation of very small particulates could result in drinking water Sr(2+) concentrations that exceed the US EPA health reference limit (4.20 mg kg(-1) body weight).

  9. High concentrations of thiosulfate in scala tympani perilymph after systemic administration in the guinea pig.

    Science.gov (United States)

    Pierre, Pernilla Videhult; Engmér, Cecilia; Wallin, Inger; Laurell, Göran; Ehrsson, Hans

    2009-02-01

    High concentrations of the antioxidant thiosulfate reach scala tympani perilymph after i.v. administration in the guinea pig. Thiosulfate concentrations in perilymph remain elevated longer than in blood. This warrants further studies on the possibility of obtaining otoprotection by thiosulfate administration several hours before that of cisplatin without compromising the anticancer effect caused by cisplatin inactivation in the blood compartment. Thiosulfate may reduce cisplatin-induced ototoxicity, presumably by oxidative stress relief and formation of inactivate platinum complexes. This study aimed to explore to what extent thiosulfate reaches scala tympani perilymph after systemic administration in the guinea pig. Scala tympani perilymph (1 microl) was aspirated from the basal turn of each cochlea up to 3 h after thiosulfate administration (103 mg/kg b.w., i.v.). Blood samples were also taken. Thiosulfate was quantified by HPLC and fluorescence detection. Substantial thiosulfate concentrations were found in perilymph. The area under the concentration-time curve for thiosulfate in perilymph and blood was 3100 microMxmin and 6300 microMxmin, respectively. The highest thiosulfate concentrations in perilymph were found at the first sampling at about 10 min. Due to a more rapid elimination from blood, perilymph concentrations exceeded those of blood towards the end of the experiment.

  10. Non-Price Competition in the Port Sector: A Case Study of Ports in Turkey

    OpenAIRE

    Soner Esmer; Hong-Oanh Nguyen, Ph.D.; Yapa Mahinda Bandara, Ph.D.; Kazim Yeni, Ph.D.

    2016-01-01

    Although the port sector has been facing increasing competition, there is limited research on how ports compete using non-price competition strategies. There are a few studies on non-price competition in the port sector. However they mainly focus on the marketing aspect. This paper seeks to fill this gap in the literature, especially from a combined marketing-economic perspective. Especially the paper's main objective is to identify the determinants of non-price competition in the port sector...

  11. CEA engineering studies and integration of the ITER diagnostic port plugs

    International Nuclear Information System (INIS)

    Doceul, L.; Walker, C.; Ingesson, C.; Ciattaglia, E.; Chappuis, P.; Portafaix, C.; Salasca, S.; Thomas, E.; Tremblay, G.; Bruyere, C.

    2007-01-01

    Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, while supporting the diagnostic equipment. CEA has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug Eq no. 01. The specific CEA contributions have been the engineering, structural and thermal analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: the conceptual design of the Eq no. 01 port plug, the static mechanical calculations, the dynamic calculation to estimate the dynamic amplification factor due to the resonance phenomenon, the thermal assessment under the neutronic load and the seismic response of the port plug inside the vacuum vessel

  12. CEA engineering studies and integration of the ITER diagnostic port plugs

    Energy Technology Data Exchange (ETDEWEB)

    Doceul, L. [Association Euratom-CEA sur la Fusion Controlee, Centre d' Etudes de Cadarache, F-13108 Saint-Paul-Lez-Durance Cedex (France)], E-mail: louis.doceul@cea.fr; Walker, C. [ITER International Team, Boltzmannstr. 2, D-85748 Garching bei Muenchen (Germany); Ingesson, C.; Ciattaglia, E. [EFDA CSU - Garching, Boltzmannstr. 2, D-85748 Garching bei Muenchen (Germany); Chappuis, P.; Portafaix, C.; Salasca, S.; Thomas, E.; Tremblay, G.; Bruyere, C. [Association Euratom-CEA sur la Fusion Controlee, Centre d' Etudes de Cadarache, F-13108 Saint-Paul-Lez-Durance Cedex (France)

    2007-10-15

    Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, while supporting the diagnostic equipment. CEA has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug Eq no. 01. The specific CEA contributions have been the engineering, structural and thermal analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: the conceptual design of the Eq no. 01 port plug, the static mechanical calculations, the dynamic calculation to estimate the dynamic amplification factor due to the resonance phenomenon, the thermal assessment under the neutronic load and the seismic response of the port plug inside the vacuum vessel.

  13. Equilibrium concentration of radionuclides in cement/groundwater/carbon steel system

    International Nuclear Information System (INIS)

    Keum, D. K.; Cho, W. J.; Hahn, P. S.

    1997-01-01

    Equilibrium concentration of major elements in an underground repository with a capacity of 100,000 drums have been simulated using the geochemical computer code (EQMOD). The simulation has been carried out at the conditions of pH 12 to 13.5, and Eh 520 and -520 mV. Solubilities of magnesium and calcium decrease with the increase of pH. The solubility of iron increases with pH at Eh -520 mV of reducing environment, while it almost entirely exists as the precipitate of Fe(OH) 3 (s) at Eh 520 mV of oxidizing environment. All of cobalt and nickel are predicted to be dissolved in the liquid phase regardless of pH since the solubility limit is greater than the total concentration. In the case of cesium and strontium, all forms of both ions are present in the liquid phase because they have negligible sorption capacity on cement and large solubility under disposal atmosphere. And thus the total concentration determines the equilibrium concentration. Adsorbed amounts of iodide and carbonate are dependent on adsorption capacity and adsorption equilibrium constant. Especially, the calcite turns out to be a solubility-limiting phase on the carbonate system. In order to validate the model, the equilibrium concentrations measured for a number of systems which consist of iron, cement, synthetic groundwater and radionuclides are compared with those predicted by the model. The concentrations between the model and the experiment of nonadsorptive elements - cesium, strontium, cobalt, nickel and iron, are well agreed. It indicates that the assumptions and the thermodynamic data in this work are valid. Using the adsorption equilibrium constant as a free parameter, the experimental data of iodide and carbonate have been fitted to the model. The model is in a good agreement with the experimental data of the iodide system. (author)

  14. Determination of the critical micelle concentration in simulations of surfactant systems

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Andrew P.; Panagiotopoulos, Athanassios Z., E-mail: azp@princeton.edu [Department of Chemical and Biological Engineering, Princeton University, Princeton, New Jersey 08544 (United States)

    2016-01-28

    Alternative methods for determining the critical micelle concentration (cmc) are investigated using canonical and grand canonical Monte Carlo simulations of a lattice surfactant model. A common measure of the cmc is the “free” (unassociated) surfactant concentration in the presence of micellar aggregates. Many prior simulations of micellizing systems have observed a decrease in the free surfactant concentration with overall surfactant loading for both ionic and nonionic surfactants, contrary to theoretical expectations from mass-action models of aggregation. In the present study, we investigate a simple lattice nonionic surfactant model in implicit solvent, for which highly reproducible simulations are possible in both the canonical (NVT) and grand canonical (μVT) ensembles. We confirm the previously observed decrease of free surfactant concentration at higher overall loadings and propose an algorithm for the precise calculation of the excluded volume and effective concentration of unassociated surfactant molecules in the accessible volume of the solution. We find that the cmc can be obtained by correcting the free surfactant concentration for volume exclusion effects resulting from the presence of micellar aggregates. We also develop an improved method for determination of the cmc based on the maximum in curvature for the osmotic pressure curve determined from μVT simulations. Excellent agreement in cmc and other micellar properties between NVT and μVT simulations of different system sizes is observed. The methodological developments in this work are broadly applicable to simulations of aggregating systems using any type of surfactant model (atomistic/coarse grained) or solvent description (explicit/implicit)

  15. Determination of the critical micelle concentration in simulations of surfactant systems

    International Nuclear Information System (INIS)

    Santos, Andrew P.; Panagiotopoulos, Athanassios Z.

    2016-01-01

    Alternative methods for determining the critical micelle concentration (cmc) are investigated using canonical and grand canonical Monte Carlo simulations of a lattice surfactant model. A common measure of the cmc is the “free” (unassociated) surfactant concentration in the presence of micellar aggregates. Many prior simulations of micellizing systems have observed a decrease in the free surfactant concentration with overall surfactant loading for both ionic and nonionic surfactants, contrary to theoretical expectations from mass-action models of aggregation. In the present study, we investigate a simple lattice nonionic surfactant model in implicit solvent, for which highly reproducible simulations are possible in both the canonical (NVT) and grand canonical (μVT) ensembles. We confirm the previously observed decrease of free surfactant concentration at higher overall loadings and propose an algorithm for the precise calculation of the excluded volume and effective concentration of unassociated surfactant molecules in the accessible volume of the solution. We find that the cmc can be obtained by correcting the free surfactant concentration for volume exclusion effects resulting from the presence of micellar aggregates. We also develop an improved method for determination of the cmc based on the maximum in curvature for the osmotic pressure curve determined from μVT simulations. Excellent agreement in cmc and other micellar properties between NVT and μVT simulations of different system sizes is observed. The methodological developments in this work are broadly applicable to simulations of aggregating systems using any type of surfactant model (atomistic/coarse grained) or solvent description (explicit/implicit)

  16. Design and implementation of a 38 kW dish-Stirling concentrated solar power system

    Science.gov (United States)

    Yan, J.; Peng, Y. D.; Cheng, Z. R.; Liu, F. M.; Tang, X. H.

    2017-11-01

    Dish-Stirling concentrated solar power system (DS-CSP) is an important pathway for converting solar energy into electricity at high efficiency. In this study, a rated power 38 kW DS-CSP system was developed (installed in Xiangtan Electric Manufacturing Group). The heat engine adopted the alpha-type four cylinders double-acting Stirling engine (Stirling Biopower Flexgen S260). The absorber flux distribution simulation was conducted using ray tracing method and then the 204 m2 parabolic dish concentrator system (diameter is 17.70 m and focal length is 9.49 m) with single concentrator plus single pillar supporting has been designed and built. A water-cooled disc target and an absorber imitation device were adopted to test the tracking performance of the dish concentrator system, homogeneity of the focal spot and flux distribution of the absorber. Finally, the S260 Stirling engine was installed on the focal position of the dish concentrator and then the net output power date of the 38 kW DS-CSP system was tested. The absorber overheating problem on the DS-CSP system performance was discussed when the DS-CSP system was installed in different locations. The testing result shows that this system achieved the net output power of 38 kW and solar-to-electricity efficiency (SEE) of 25.3% with the direct normal irradiation (DNI) at 750 W/m2. The net output power can further increase to 40.5 kW with the SEE of 26.6% when the DNI reaches up to the maximum of 761 W/m2. The net output power of the 38 kW DS-CSP system has a linear function relationship with the DNI. The fitting function is Net power output=0.1003×DNI-36.129, where DNI is at the range of 460∼761 W/m2. This function could be used to predict the amount of the 38 kW DS-CSP system annual generation power.

  17. Control systems for the dissolved oxygen concentration in condensate- and feed-water systems in nuclear power plants

    International Nuclear Information System (INIS)

    Mikajiri, Motohiko; Hosaka, Seiichi.

    1981-01-01

    Purpose: To surely prevent the generation of corrosion products and contaminations in the systems thereby decreasing the exposure dose to operators in BWR type nuclear power plants. Constitution: Dissolved oxygen concentration in condensates is measured by a dissolved oxygen concentration meter disposed to the pipeway down stream of the condensator and the measured value is sent to an injection amount control mechanism for heater drain water. The control mechanism controls the injection amount from the injection mechanism that injection heater drain water from a feed-water heater to the liquid phase in the hot wall of the condensator. Thus, heater drawin water at high dissolved oxygen is injected to the condensates in the condensator which is de-airated and reduced with dissolved oxygen concentration, to maintain the dissolved oxygen concentration at a predetermined level, whereby stable oxide films are formed to the inner surface of the pipeways to prevent the generation of corrosion products such as rusts. (Furukawa, Y.)

  18. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  19. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  20. Augmented switching linear dynamical system model for gas concentration estimation with MOX sensors in an open sampling system.

    Science.gov (United States)

    Di Lello, Enrico; Trincavelli, Marco; Bruyninckx, Herman; De Laet, Tinne

    2014-07-11

    In this paper, we introduce a Bayesian time series model approach for gas concentration estimation using Metal Oxide (MOX) sensors in Open Sampling System (OSS). Our approach focuses on the compensation of the slow response of MOX sensors, while concurrently solving the problem of estimating the gas concentration in OSS. The proposed Augmented Switching Linear System model allows to include all the sources of uncertainty arising at each step of the problem in a single coherent probabilistic formulation. In particular, the problem of detecting on-line the current sensor dynamical regime and estimating the underlying gas concentration under environmental disturbances and noisy measurements is formulated and solved as a statistical inference problem. Our model improves, with respect to the state of the art, where system modeling approaches have been already introduced, but only provided an indirect relative measures proportional to the gas concentration and the problem of modeling uncertainty was ignored. Our approach is validated experimentally and the performances in terms of speed of and quality of the gas concentration estimation are compared with the ones obtained using a photo-ionization detector.