WorldWideScience

Sample records for por icp aes

  1. Toepassing ICP-AES op het RIKILT

    NARCIS (Netherlands)

    Ruig, de W.G.

    1980-01-01

    Rapportage over de toepassing van ICP-AES op het RIKILT. Bij ICP-AES worden twee manieren van lichtemissie detectie toegepast nl. simultaan en sequentieel. De voor- en nadelen van ICP-AES t.o.v. AAS worden op een rij gezet.

  2. Comparative study for essential elements determination in milk products samples by INAA and ICP-AES; Estudo comparativo na determinacao de elementos essenciais em amostras de produtos lacteos por AANI e ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Kira, Carmen S. [Instituto Adolfo Lutz, Sao Paulo, SP (Brazil). Secao de Equipamentos Especializados; Maihara, Vera A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao Neutronica

    2002-07-01

    The mineral elements Ca, Fe, K, Mg, Na and Zn were analyzed in milk products by using instrumental neutron activation analysis (INAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The study included four types of cheese (mozzarella, minas, prato, parmesan), chocolate milk and yogurt. The samples were purchased from the local markets. Average concentrations ranged from 3668 (chocolate milk) to 16558 (parmesan cheese) mg/kg for Ca; from 2.61 (parmesan cheese) to 28.9 (chocolate milk) mg/kg for Fe; from 673 (mozzarella cheese) to 10492 (chocolate milk) mg/kg for K; from 398 (yogurt) to 2280 (minas cheese) mg/kg for Mg; from 1681 (yogurt) to 15248 (parmesan cheese) mg/kg for Na; from 12.1 (chocolate milk) to 71.8 (parmesan cheese) mg/kg for Zn. Two National Institute of Standards and Technology (NIST) standard reference materials (SRM 8435 Whole Milk Powder and SRM 1549 Non Fat Milk Powder) were analyzed to verify method accuracy. The statistic test used to determine the significance of the difference between the techniques was based on Unpaired t-Student test. Statistical test revealed no significance differences (P< 0,05) between the average values provided by the two methods for the most of determined elements. (author)

  3. Determination of organic phosphorous in oil production waters by ICP-AES and ICP-MS after preconcentration on silica immobilized C{sub 18}; Determinacao de fosforo organico em aguas de producao petrolifera por ICP-AES e ICP-MS apos pre-concentracao em coluna de silica C{sub 18}

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Anderson Araujo; Miekeley, Norbert; Silveira, Carmem Lucia Porto da [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Quimica; Bezerra, Maria Carmem Moreira [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    1998-10-01

    Results on the optimization analytical methods for the determination of phosphorous in phosphino-poly carboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination in necessary. In this work, mini columns of silica immobilized C{sub 18} were used. Optimization of the separation step resulted in the following working conditions: (1) pre washing of the column with methanol (80% v/v); (2) use of a flow rate of 5 m L/min and 10 m L/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 m L of buffer of H{sub 3} BO{sub 3}/Na OH (0.05 M, p H 9) with a flow rate of 1 m L/min. Sample detection limits (3{sigma}) for different combinations of nebulizers and spectrometric methods, based on 10 m L water aliquots, are: ICP-AES-Cross flow (47 mg/L) and Ultrasonic (18 {mu}g/L); ICP-M S-Cross flow (1.2 {mu}g/L) and Ultrasonic (0.5 {mu}g/L). Typical recoveries of organic phosphorous are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well N A 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods., resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts. (author)

  4. Multielemental analysis of Korean geological reference samples by INAA, ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Naoki Shirai; Hiroki Takahashi; Yuta Yokozuka; Mitsuru Ebihara; Meiramkhan Toktaganov; Shun Sekimoto

    2015-01-01

    Six Korean geological reference samples (KB-1, KGB-1, KT-1, KD-1, KG-1 and KG-2) prepared by Korea Institutes of Geoscience and Mineral Resources were analyzed by using INAA, ICP-AES and ICP-MS. Some elements could be determined by both INAA and non-INAA methods (ICP-AES and ICP-MS), and these data are consistent with each other. This study confirms that a combination of ICP-AES and ICP-MS is comparable to INAA in determining a wide range of major, minor and trace elements in geological materials. (author)

  5. Obsidian provenance studies in archaeology: A comparison between PIXE, ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Bellot-Gurlet, Ludovic; Poupeau, Gerard; Salomon, Joseph; Calligaro, Thomas; Moignard, Brice; Dran, Jean-Claude; Barrat, Jean-Alix; Pichon, Laurent

    2005-01-01

    Elemental composition fingerprinting by PIXE technique is very attractive for obsidian provenance studies as it may proceed in a non-destructive mode, even if a more complete elemental characterization can be obtained by ICP-MS and/or ICP-AES. Only few studies have compared results obtained by both methods for solid rock samples. In this work, elemental compositions were determined by ICP-MS/-AES for international geochemical standards and by ICP-MS/-AES and PIXE for inter-laboratory reference obsidians. In addition 49 obsidian source samples and artefacts were analysed by both ICP-MS/-AES and PIXE. Instrumental work and measurement quality control performed for obsidian chemical characterization, underline that PIXE and ICP-MS/-AES provide reproducible, accurate and comparable measurements. In some volcanic districts the limited number of elements dosed by PIXE is sufficient for the discrimination of the potential raw sources of obsidians. Therefore, PIXE can be an advantageous substitute to ICP-MS/-AES techniques for provenance studies

  6. Determinação de fósforo orgânico em águas de produção petrolífera por ICP- AES e ICP- MS após pré-concentração em coluna de sílica-C18 Determination of organic phosphorus in oil production waters by ICP-AES and ICP-MS after preconcentration on silica immobilized C18

    Directory of Open Access Journals (Sweden)

    Anderson Araújo Rocha

    1998-10-01

    Full Text Available Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA, used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1 prewashing of the column with methanol (80% v/v; (2 use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3 final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9 with a flow rate of 1 mL/min. Sample detection limits (3s for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L and Ultrasonic (18 mug/L; ICP-MS -Cross flow (1.2 mug/L, Cyclonic (0.7 mug/L and Ultrasonic (0.5 mug/L. Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.

  7. ICP/AES radioactive sample analyses at Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Matsuzaki, C.L.; Hara, F.T.

    1986-03-01

    Inductively coupled argon plasma atomic emission spectroscopy (ICP/AES) analyses of radioactive materials at Pacific Northwest Laboratory (PNL) began about three years ago upon completion of the installation of a modified Applied Research Laboratory (ARL) 3560. Funding for the purchase and installation of the ICP/AES was provided by the Nuclear Waste Materials Characterization Center (MCC) established at PNL by the Department of Energy in 1979. MCC's objective is to ensure that qualified materials data are available on waste materials. This paper is divided into the following topics: (1) Instrument selection considerations; (2) initial installation of the simultaneous system with the source stand enclosed in a 1/2'' lead-shielded glove box; (3) retrofit installation of the sequential spectrometer; and (4) a brief discussion on several types of samples analyzed. 1 ref., 7 figs., 1 tab

  8. ICP-AES determination of trace elements in carbon steel

    International Nuclear Information System (INIS)

    Sengupta, Arijit; Rajeswari, B.; Kadam, R.M.; Babu, Y.; Godbole, S.V.

    2010-01-01

    Full text: Carbon steel, a combination of the elements iron and carbon, can be classified into four types as mild, medium, high and very high depending on the carbon content which varies from 0.05% to 2.1%. Carbon steel of different types finds application in medical devices, razor blades, cutlery and spring. In the nuclear industry, it is used in feeder pipes in the reactor. A strict quality control measure is required to monitor the trace elements, which have deleterious effects on the mechanical properties of the carbon steel. Thus, it becomes imperative to check the purity of carbon steel as a quality control measure before it is used in feeder pipes in the reactor. Several methods have been reported in literature for trace elemental determination in high purity iron. Some of these include neutron activation analysis, atomic absorption spectrometry and atomic emission spectrometry. Inductively coupled plasma atomic emission spectrometry (ICP-AES) is widely recognized as a sensitive technique for the determination of trace elements in various matrices, its major advantages being good accuracy and precision, high sensitivity, multi-element capability, large linear dynamic range and relative freedom from matrix effects. The present study mainly deals with the direct determination of trace elements in carbon steel using ICP-AES. An axially viewing ICP spectrometer having a polychromator with 35 fixed analytical channels and limited sequential facility to select any analytical line within 2.2 nm of a polychromator line was used in these studies. Iron, which forms one of the main constituents of carbon steel, has a multi electronic configuration with line rich emission spectrum and, therefore, tends to interfere in the determination of trace impurities in carbon steel matrix. Spectral interference in ICP-AES can be seriously detrimental to the accuracy and reliability of trace element determinations, particularly when they are performed in the presence of high

  9. Eletrodissolução de ligas de latão empregando sistemas de análise em fluxo para a determinação de cobre, zinco e chumbo por ICP-AES Electrodissolution of brasses alloys employing flow systems for determination of copper, zinc and lead by ICP-AES

    Directory of Open Access Journals (Sweden)

    Ana Paula G. Gervasio

    1999-09-01

    Full Text Available An on-line electrodissolution procedure implemented in a flow injection system for determination of copper, zinc and lead in brasses alloys by ICP-AES is described. Sample dissolution procedure was carried out by using a PTFE chamber and a DC power supply with constant current. Solid sample was attached to chamber as anode and a gold tubing coupled in the chamber was used as cathode. An electrolytic solution flowing through the gold tubing closed the electric circuit with sample, in order to provide condition for electric dissolution when the DC power supply was switched on. The best results were achieved by using a 1.5 mol l-1 nitric acid solution as electrolyte and a 2.5 A current intensity. The procedure presented a good performance characterized by a relative standard deviation better than < 5% (n=5 and a sample throughput of 180 determinations per hour for Cu, Zn and Pb. Results were in agreement with those obtained by conventional acid dissolution (99% confidence level.

  10. Chemical separation and ICP-AES determination of rare earths in Al2O3 matrix

    International Nuclear Information System (INIS)

    Argekar, A.A.; Kulkarni, M.J.; Page, A.G.; Manchanda, V.K.

    2005-01-01

    A chemical separation-ICP-AES method has been developed for determination of rare earths in alumina matrix. The quantitative separation of rare earths has also been confirmed using radiotracers. (author)

  11. PIXE analysis of human stones: comparison with data from ICP-AES

    International Nuclear Information System (INIS)

    Pougnet, M.A.B.; Peisach, M.; Pineda, C.A.; Rodgers, A.L.

    1987-01-01

    25 human stone samples previously analyzed by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and the IAEA Animal Bone Standard Reference Material were used to evaluate trace element analysis by PIXE. Bombardment with 4 MeV protons was used for the determination of Mn, Fe, Cu, Pb, Br, Rb, Sr and Ca. PIXE and ICP-AES data gave correlation factors better than 0.97 for the elements Ca, Fe, Zn, Sr and Pb. (author) 9 refs.; 5 figs

  12. Comparison of elemental quantity by PIXE and ICP-MS and/or ICP-AES for NIST standards

    International Nuclear Information System (INIS)

    Saitoh, K.; Sera, K.; Gotoh, T.; Nakamura, M.

    2002-01-01

    Urban particulate matter (SRM 1648), Buffalo River sediment (SRM 2704) and pine needle (SRM 1575) standard reference materials prepared by the National Institute of Standards and Technology (NIST, USA) were analyzed by three multi-element analysis methods, i.e., particle induced X-ray emission (PIXE), inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES); values determined by those analysis methods were compared with certified and/or non-certified values of NIST samples. Values determined by PIXE were 70-120% relative to certified and/or non-certified values of NIST samples except for Co in the urban particulate matter, for V and Co in Buffalo River sediment and for Ni and Br in the pine needles samples. In particular, Al, K, Ca, Cr, Mn, Fe, Cu, Zn and Pb were 85-110% in all samples. On the other hand, Na and Fe values determined by ICP-MS were very much different from the certified values in all samples, but the other elements were 70-120%. As for ICP-AES, all elements except for Na were 80-100% in all samples. Comparing the values determined by PIXE and those determined by ICP-MS and/or ICP-AES, there was a slight difference between the samples, but the range was 75-120% except for Na, V, Fe and Co determined by ICP-MS and Na determined by ICP-AES, which was generally consistent with PIXE

  13. Environmental application of XRF, ICP-AES and INAA on biological matrix

    International Nuclear Information System (INIS)

    Zararsiz, A.; Dogangun, A.; Tuncel, S.

    2004-01-01

    Full text: It is very important to determine trace quantities of metals in different matrices with high accuracy since the metals are used as markers for different sources in air pollution studies. In this study, the analytical capabilities of XRF, ICP-AES and INM techniques on a biological matrix namely lichens, which are widely used as bio monitoring organisms for the pollutants mapping in the atmosphere, were tested. Lichen samples were collected in Aegean Region of Turkey where pollution is an important issue. 9 elements were determined by XRF, 14 elements by ICP-AES and 13 elements by INM. Quality assurance was achieved using lichen SRM (IAEA-336) and Orchard leaves SRM (NIST- 1571). Produced data are subjected to statistical tests, like t-test, Q-test in order to determine the accuracy and precision of each technique. A recommendation list of the proper analytical technique is obtained for determination of each specific element considering analytical capabilities of ICP-AES, XRF and INM. As a result we can recommend that the first choice for Cd, Cu, Mg is ICP-AES, for In, K, Rb is INAA, for Br is XRF, if the concentrations are not close to the detection limit of XRF. For V, Cr, AI, Na, Fe ICP-AES and INM are both well, for Pb ICP-AES and XRF are both well, if the concentrations are not close to the detection limit of XRF, for Mn and Ca INM, XRF and ICP-AES are all give similar results for this type of biological matrix

  14. Microwave digestion techniques applied to determination of boron by ICP-AES in BNCT program; Digestion de matrices biologicas asistida por microondas para el analisis espectrometrico de boro en BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Silvia S; Di Santo, Norberto R; Garavaglia, Ricardo N; Pucci, Gladys N; Batistoni, Daniel A [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Quimica; Schwint, Amanda E [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Radiobiologia

    1999-07-01

    Recently, boron neutron capture therapy (BNCT) has merged as an interesting option for the treatment of some kind of tumors where established therapies show no success. A molecular boronated species, enriched in {sup 10}B is administrated to the subject; it localizes in malignant tissues depending the kind of tumor and localization. Therefore, a very important fact in BNCT research is the detection of boron at trace or ultra trace levels precisely and accurately. This is extremely necessary as boronated species do localize in tumoral tissue and also localize in liver, kidney, spleen, skin, membranes. By this way, before testing a boronated species, it is mandatory to determine its biodistribution in a statistically meaning population, that is related with managing of a great number of samples. In the other hand, it is necessary to exactly predict when to begin the irradiation and to determine the magnitude of radiation to obtain the desired radiological dose for a specified mean boron concentration. This involves the determination of boron in whole blood, which is related with boron concentration in the tumor object of treatment. The methodology selected for the analysis of boron in whole blood and tissues must join certain characteristics: it must not be dependant of the chemical form of boron, it has to be fast and capable to determine boron accurately and precisely in a wide range of concentrations. The design and validation of experimental models involving animals in BNCT studies and the determination of boron in blood of animals and subjects upon treatment require reliable analytical procedures to determine boron quantitatively in those biologic materials. Inductively coupled plasma-atomic emission spectrometry (ICP-AES) using pneumatic nebulization is one of the most promising methods for boron analysis, but the sample must be liquid and have low solid concentration. In our case, biological tissues and blood, it is mandatory to mineralize and/or dilute

  15. Some aspects of ICP-AES analysis of high purity rare earths

    International Nuclear Information System (INIS)

    Murty, P.S.; Biswas, S.S.

    1991-01-01

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) is a technique capable of giving high sensitivity in trace elemental analysis. While the technique possesses high sensitivity, it lacks high selectivity. Selectivity is important where substances emitting complex spectra are to be analysed for trace elements. Rare earths emit highly complex spectra in a plasma source and the determination of adjacent rare earths in a high purity rare earth matrix, with high sensitivity, is not possible due to the inadequate selectivity of ICP-AES. One approach that has yielded reasonably good spectral selectivity in the high purity rare earth analysis by ICP-AES is by employing a combination of wavelength modulation techniques and high resolution echelle grating. However, it was found that by using a high resolution monochromator senstitivities either comparable to or better than those reported by the wavelength modulation technique could be obtained. (author). 2 refs., 2 figs., 2 tabs

  16. Estimation of metal ions during the dissolution of corrosion product oxides by ICP-AES

    International Nuclear Information System (INIS)

    Sathyaseelan, V.S.; Mittal, Vinit Kumar; Velmurugan, S.

    2012-01-01

    Inductively coupled plasma atomic emission spectroscopy (ICP-AES) is one of the several techniques, which is being widely used for both qualitative and quantitative estimation of various elements. Determination of metals in wine, arsenic in food, trace elements in soil, nutrient levels in agricultural soils, trace elements bound to protein, motor oil analysis etc. are the examples of its application. ICP-AES utilizes plasma as the atomization and excitation source. The plasma temperature in the analytical zone ranges from 5000-8000 K. This high temperature assures that most of the compounds in the samples are completely atomized. Advantages of ICP-AES are high sensitivity and linear dynamic range, multi-element capability, low chemical interference and a stable and reproducible signal. The typical limits of detection for some of the elements like Mg, Sr, Ca, Li, Cu etc are well below 1 μg L -1

  17. Multielement determination of major-to-ultratrace elements in salmon egg by ICP-AES and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Hirotaka; Haraguchi, Hiroki [Nagoya Univ., Graduate School of Engineering, Dept. of Applied Chemistry, Nagoya, Aichi (Japan)

    2002-04-01

    The multielement determination of major-to-ultratrace elements in salmon egg was carried out by ICP-AES and ICP-MS. First, salmon eggs (30 eggs used) were digested with conc. nitric acid and 60% perchloric acid by heating almost to dryness repeatedly. Finally, the residues of salmon eggs were dissolved in 1 M nitric acid and the sample solutions were analyzed by ICP-AES and ICP-MS. About 40 elements could be determined over the concentration range in 9 orders of magnitude. The concentrations of bio-essential elements, such as Zn, Fe, and Cu, in salmon egg were 10-100 times higher than those in human blood serum. In addition, the major-to-ultratrace elements in cell cytoplasm and cell membrane were separately determined in a similar manner to those in whole egg cell. The concentrations of most bio-essential elements were higher in cell cytoplasm than in cell membrane, while those of Fe and Cu were higher in cell membrane than in cell cytoplasm of salmon egg. (author)

  18. Forensic discrimination of aluminum foil by SR-XRF and ICP-AES

    International Nuclear Information System (INIS)

    Kasamatsu, Masaaki; Suzuki, Yasuhiro; Suzuki, Shinichi; Miyamoto, Naoki; Watanabe, Seiya; Shimoda, Osamu; Takatsu, Masahisa; Nakanishi, Toshio

    2010-01-01

    The application of synchrotron radiation X-ray fluorescence spectrometry (SR-XRF) was investigated for the forensic discrimination of aluminum foil by comparisons of the elemental components. Small fragments (1 x 1 mm) were taken from 4 kinds of aluminum foils produced by different manufactures and used for measurements of the XRF spectrum at BL37XU of SPring-8. A comparison of the XRF spectra was effective for the discrimination of aluminum foils from different sources, because significant differences were observed in the X-ray peak intensities of Fe, Cu, Zn, Ga, Zr and Sn. These elements, except for Zr and Sn in the aluminum foils and NIST SRM1258 (Aluminium Alloy 6011), were also determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). The observed values of Fe, Cu, Zn and Ga in NIST standard samples by ICP-AES showed satisfactorily good agreements with the certified or information values with relative standard deviations from 1.1% for Zn to 6.7% for Ga. The observed values for the aluminum foils by ICP-AES were compared with those by SR-XRF. Correlation coefficients from 0.997 for Cu/Fe to 0.999 for Zn/Fe and Ga/Fe were obtained between the ratio of the elemental concentration by ICP-AES and normalized the X-ray intensity by SR-XRF. This result demonstrates that a comparison of the normalized X-ray intensity is nearly as effective for the discrimination of aluminum foils as quantitative analysis by ICP-AES. Comparisons of the analytical results by SR-XRF allow the discrimination of all aluminum foils using only a 1 mm 2 fragment with no destruction of the samples. (author)

  19. Separation techniques for the clean-up of radioactive mixed waste for ICP-AES/ICP-MS analysis

    International Nuclear Information System (INIS)

    Swafford, A.M.; Keller, J.M.

    1993-01-01

    Two separation techniques were investigated for the clean-up of typical radioactive mixed waste samples requiring elemental analysis by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) or Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). These measurements frequently involve regulatory or compliance criteria which include the determination of elements on the EPA Target Analyte List (TAL). These samples usually consist of both an aqueous phase and a solid phase which is mostly an inorganic sludge. Frequently, samples taken from the waste tanks contain high levels of uranium and thorium which can cause spectral interferences in ICP-AES or ICP-MS analysis. The removal of these interferences is necessary to determine the presence of the EPA TAL elements in the sample. Two clean-up methods were studied on simulated aqueous waste samples containing the EPA TAL elements. The first method studied was a classical procedure based upon liquid-liquid extraction using tri-n- octylphosphine oxide (TOPO) dissolved in cyclohexane. The second method investigated was based on more recently developed techniques using extraction chromatography; specifically the use of a commercially available Eichrom TRU·Spec trademark column. Literature on these two methods indicates the efficient removal of uranium and thorium from properly prepared samples and provides considerable qualitative information on the extraction behavior of many other elements. However, there is a lack of quantitative data on the extraction behavior of elements on the EPA Target Analyte List. Experimental studies on these two methods consisted of determining whether any of the analytes were extracted by these methods and the recoveries obtained. Both methods produced similar results; the EPA target analytes were only slightly or not extracted. Advantages and disadvantages of each method were evaluated and found to be comparable

  20. Integrated Design for Marketing and Manufacturing team: An examination of LA-ICP-AES in a mobile configuration. Final report

    International Nuclear Information System (INIS)

    1994-05-01

    The Department of Energy (DOE) has identified the need for field-deployable elemental analysis devices that are safer, faster, and less expensive than the fixed laboratory procedures now used to screen hazardous waste sites. As a response to this need, the Technology Integration Program (TIP) created a mobile, field-deployable laser ablation-inductively coupled plasma-atomic emission spectrometry (LA-ICP-AES) sampling and analysis prototype. Although the elemental. screening prototype has been successfully field-tested, continued marketing and technical development efforts are required to transfer LA-ICP-AES technology to the commercial sector. TIP established and supported a student research and design group called the Integrated Design for Marketing and Manufacturing (IDMM) team to advance the technology transfer of mobile, field-deployable LA-ICP-AES. The IDMM team developed a conceptual design (which is detailed in this report) for a mobile, field-deployable LA-ICP-AES sampling and analysis system, and reports the following findings: Mobile, field-deployable LA-ICP-AES is commercially viable. Eventual regulatory acceptance of field-deployable LA-ICP-AES, while not a simple process, is likely. Further refinement of certain processes and components of LA-ICP-AES will enhance the device's sensitivity and accuracy

  1. Development of ICP-AES based method for the characterization of high level waste

    International Nuclear Information System (INIS)

    Seshagiri, T.K.; Thulsidas, S.K.; Adya, V.C.; Kumar, Mithlesh; Radhakrishnan, K.; Mary, G.; Kulkarni, P.G.; Bhalerao, Bharti; Pant, D.K.

    2011-01-01

    An Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) method was developed for the trace metal characterization of high level waste solutions (HLW) of different origin and the method was validated by analysis of synthetic samples of simulated high level waste solutions (SHLW) from spent fuels of varying composition. In this context, an inter-laboratory comparison exercise (ILCE) was carried out with the simulated HLW of different spent fuel types, viz., research reactor (RR), pressurized heavy water reactor (PHWR) and fast breeder reactor (FBR). An over view of the ICP-AES determination of trace metallic constituents in such SHLW solutions is presented. The overall agreement between the various laboratories was good. (author)

  2. ICP-AES analysis of trace elements in serum from animals fed with irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi

    1986-01-01

    A method of trace element analysis by ICP-AES in serum from animals fed with irradiated food is described. In order to demonstrate that irradiated food is suitable for human consumption, it is necessary to perform an experiment of animal feeding with these food before use for human. Trace element analysis in animal serum could provide an actual evidence for further human consumption study. 53 serum samples of the rats fed with irradiated food were obtained. After ashed and solved, ICP-AES analysis has been used for determining 20 trace elements in specimen solution. The detection limitation is in the range of 10 -2 -10 -3 ppm for different elements. The recovery of elements is from 70.08% to 98.28%. The relative standard deviation is found to be 0.71% to 11.52%

  3. Spectral interference of zirconium on 24 analyte elements using CCD based ICP-AES technique

    International Nuclear Information System (INIS)

    Adya, V.C.; Sengupta, Arijit; Godbole, S.V.

    2014-01-01

    In the present studies, the spectral interference of zirconium on different analytical lines of 24 critical analytes using CCD based ICP-AES technique is described. Suitable analytical lines for zirconium were identified along with their detection limits. The sensitivity and the detection limits of analytical channels for different elements in presence of Zr matrix were calculated. Subsequently analytical lines with least interference from Zr and better detection limits were selected for their determinations. (author)

  4. Simultaneous multielement analysis of zirconium alloys by chlorination separation of matrix/ICP-AES

    International Nuclear Information System (INIS)

    Kato, Kaneharu

    1990-01-01

    An analytical method combined chlorination separation of matrix with ICP-AES has been developed for reactor grade Zr alloys (Zircaloy-2). A sample (1 g) is taken into a Pt boat and chlorinated with HCl gas of 100 ml/min in a glass reaction tube at ca. 330degC. Matrix Zr of the sample is volatilized and separated as ZrCl 4 . The analytic elements remaining quantitatively as chlorination residue are dissolved in a mixture of mineral acids (6 M HCl 3 ml+conc. HNO 3 0.5 ml+conc. H 2 SO 4 0.2 ml) and diluted to 20 ml with distilled water after filtration. ICP-AES was used for simultaneous multielement determination using a calibration curve method. The present method has the following advantages: simple sample preparation procedure; applicability to any form of samples to determine multielements; simple ICP-AES calibration procedure. This method was successfully applied to the determination of Fe, Ni, Cu, Co, Mn and Pb in the Zr alloys of JAERI CRM's and NBS SRM's. (author)

  5. Transition metal analysis. A comparison between ICP-AES and deuteron activation

    International Nuclear Information System (INIS)

    Pillay, A.E.; Williams, J.R.; Hassan, S.M.; Al-Hamdi, A.; El Mardi, M.O.

    2002-01-01

    The analytical capabilities of ICP-AES (ICP) and deuteron activation (associated with prompt gamma-rays and delayed X-rays) for the determination of certain transition metals, were investigated. The sensitivities of the three methods are given, and the general applicability of each technique is evaluated. In the case of ICP, numerical data were obtained from aqueous solutions containing digested plant material. These experimental results were assessed against minimum detectable limits attained in relevant solid matrices that were subjected to prompt gamma-ray and delayed X-ray spectrometry using 5 MeV 2 H + ions. The analytically useful lines originated mainly from (d,p) and (d,n) reactions. The potential of the three techniques for routine analysis is discussed and detailed methodologies are presented. (author)

  6. Radiochemical separation and ICP-AES determination of some common metallic elements in ThO2 matrix

    International Nuclear Information System (INIS)

    Adya, V.C.; Hon, N.S.; Bangia, T.R.; Sastry, M.D.; Iyer, R.H.

    1997-01-01

    Radioactive tracer and also ICP-AES studies have been carried out to determine Al, Cd, Ca, Cr, Co, Cu, Mn, Mo and Pd in ThO 2 matrix after chemical separation. Di-2-ethyl-hexyl phosphoric acid/xylene/HNO 3 extraction system was used for quantitative separation of thorium. The recovery of elements as determined by tracers and ICP-AES was found to be quantitative within experimental error. (author). 3 refs., 1 tab

  7. Quantification of immobilized Candida antarctica lipase B (CALB) using ICP-AES combined with Bradford method.

    Science.gov (United States)

    Nicolás, Paula; Lassalle, Verónica L; Ferreira, María L

    2017-02-01

    The aim of this manuscript was to study the application of a new method of protein quantification in Candida antarctica lipase B commercial solutions. Error sources associated to the traditional Bradford technique were demonstrated. Eight biocatalysts based on C. antarctica lipase B (CALB) immobilized onto magnetite nanoparticles were used. Magnetite nanoparticles were coated with chitosan (CHIT) and modified with glutaraldehyde (GLUT) and aminopropyltriethoxysilane (APTS). Later, CALB was adsorbed on the modified support. The proposed novel protein quantification method included the determination of sulfur (from protein in CALB solution) by means of Atomic Emission by Inductive Coupling Plasma (AE-ICP). Four different protocols were applied combining AE-ICP and classical Bradford assays, besides Carbon, Hydrogen and Nitrogen (CHN) analysis. The calculated error in protein content using the "classic" Bradford method with bovine serum albumin as standard ranged from 400 to 1200% when protein in CALB solution was quantified. These errors were calculated considering as "true protein content values" the results of the amount of immobilized protein obtained with the improved method. The optimum quantification procedure involved the combination of Bradford method, ICP and CHN analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Todoli, Jose L. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, 03080 Alicante (Spain)]. E-mail: jose.todoli@ua.es; Mermet, Jean M. [Spectroscopy Forever, 01390 Tramoyes (France)

    2006-03-15

    There are many fields in which the available sample volume is the limiting factor for an elemental analysis. Over the last ten years, sample introduction systems used in plasma spectrometry (i.e., Inductively Coupled Plasma Atomic Emission Spectrometry, ICP-AES, and Mass Spectrometry, ICP-MS) have evolved in order to expand the field of applicability of these techniques to the analysis of micro- and nanosamples. A full understanding of the basic processes occurring throughout the sample introduction system is absolutely necessary to improve analytical performance. The first part of the present review deals with fundamental studies concerning the different phenomena taking place from aerosol production to analyte excitation/ionization when the liquid consumption rate does not exceed 100 {mu}l/min. Existing sample introduction systems are currently far from the ideal and a significant effort has been made to develop new and efficient devices. Different approaches for continuously introducing small sample volumes (i.e., microsamples) have been reviewed and compared in the present work. Finally, applications as well as basic guidelines to select the best sample introduction system according to the sample particularities are given at the end of this review.

  9. Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Todoli, Jose L.; Mermet, Jean M.

    2006-01-01

    There are many fields in which the available sample volume is the limiting factor for an elemental analysis. Over the last ten years, sample introduction systems used in plasma spectrometry (i.e., Inductively Coupled Plasma Atomic Emission Spectrometry, ICP-AES, and Mass Spectrometry, ICP-MS) have evolved in order to expand the field of applicability of these techniques to the analysis of micro- and nanosamples. A full understanding of the basic processes occurring throughout the sample introduction system is absolutely necessary to improve analytical performance. The first part of the present review deals with fundamental studies concerning the different phenomena taking place from aerosol production to analyte excitation/ionization when the liquid consumption rate does not exceed 100 μl/min. Existing sample introduction systems are currently far from the ideal and a significant effort has been made to develop new and efficient devices. Different approaches for continuously introducing small sample volumes (i.e., microsamples) have been reviewed and compared in the present work. Finally, applications as well as basic guidelines to select the best sample introduction system according to the sample particularities are given at the end of this review

  10. Determination of Boron in Zircaloy by using ICP-AES and Colorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Goo; Pyo, Hyung-Ryul; Choi, Kwang-Soon; Han, Sun-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2007-10-15

    Zircaloy has been being widely used in the nuclear industry because of the low cross section of Zirconium against a thermal neutron. Accurate composition data of Zircaloy for Hf, B, and so on having a high cross section against thermal neutron is important to use it as a nuclear material. Accordingly proper determination methods of these elements in Zircaloy are needed. In this study, the application of two methods, ICP-AES and a colorimetry using methylene blue were investigated in order to establish a proper analysis method of Boron in the range from tens to hundreds ug B/g sample of Zircaloy.

  11. Determination of Boron in Zircaloy by using ICP-AES and Colorimetry

    International Nuclear Information System (INIS)

    Kim, Jong-Goo; Pyo, Hyung-Ryul; Choi, Kwang-Soon; Han, Sun-Ho

    2007-01-01

    Zircaloy has been being widely used in the nuclear industry because of the low cross section of Zirconium against a thermal neutron. Accurate composition data of Zircaloy for Hf, B, and so on having a high cross section against thermal neutron is important to use it as a nuclear material. Accordingly proper determination methods of these elements in Zircaloy are needed. In this study, the application of two methods, ICP-AES and a colorimetry using methylene blue were investigated in order to establish a proper analysis method of Boron in the range from tens to hundreds ug B/g sample of Zircaloy

  12. Uncertainty assessing of measure result of tungsten in U3O8 by ICP-AES

    International Nuclear Information System (INIS)

    Du Guirong; Nie Jie; Tang Lilei

    2011-01-01

    According as the determining method and the assessing criterion,the uncertainty assessing of measure result of tungsten in U 3 O 8 by ICP-AES is researched. With the assessment of each component in detail, the result shows that u rel (sc)> u rel (c)> u rel (F)> u rel (m) by uncertainty contribution. Other uncertainty is random, calculated by repetition. u rel (sc) is contributed to uncertainty mainly. So the general uncertainty is reduced with strict operation to reduce u rel (sc). (authors)

  13. Determination of traces of thorium in ammonium/sodium diuranate by ICP-AES method

    International Nuclear Information System (INIS)

    Nair, V.R.; Kartha, K.N.M.

    1999-01-01

    Full text: Indian Rare Earths Ltd., Alwaye, produces ammonium diuranate from the thorium concentrate, obtained during monazite processing. This process involves a series of steps. The final uranium product obtained always contains microgram amounts of thorium as impurity. An analytical procedure has been standardised for the estimation of microgram amounts of thorium in ammonium/sodium diuranate. The method involves solvent extraction of uranium by using a tertiary amine followed by the determination of thorium by ICP-AES method in the raffinate. The recoveries of thorium were checked by standard addition to the uranium matrix. Limit of detection is adequate for the analysis of nuclear grade material

  14. Determination of Nb and Zr in U-Nb-Zr alloys by ICP-AES

    International Nuclear Information System (INIS)

    Wang Cuiping; Dong Shizhe; Li Lin; He Meiying

    2003-01-01

    The U-Nb-Zr alloy sample is dissolved by HNO 3 , H 2 O 2 and HF, and the contents of Nb and Zr in the sample are determined on the JY-70 II type ICP-AES by using the internal standard synchronous dilution method. The range of determination is 1%-10% and 0.33%-3.33%, respectively for Nb and Zr. The relative standard deviation is better than 3.2% for Nb, and 2.5% for Zr. The method is rapid and convenient for determining Nb and Zr in U-Nb-Zr alloy sample

  15. Multielement determination and speciation of major-to-ultratrace elements in green tea leaves by ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Matsuura, Hirotaka; Hokura, Akiko; Haraguchi, Hiroki

    2000-01-01

    In order to investigate the multi-elemental composition of green tea leaves as well as chemical species in tea infusions, inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS) were used for elemental analysis and elemental speciation with the aid of size exclusion chromatography (SEC). As a result, the multielement determination of major-to-ultratrace elements in green tea leaves and green tea infusions was carried out by ICP-AES and ICP-MS. About 40 elements in these tea samples could be determined in a wide concentration range of over 8 orders of magnitude. The extraction efficiency of each element was estimated as the ratio of its concentration in tea infusion to that in tea leaves. It was found from the experimental results that the elements in tea leaves could be classified into three characteristic groups, depending on their extraction efficiencies. Furthermore, tea infusions were analyzed by a combined system of SEC, UV absorption detector, and ICP-AES (or ICP-MS) for the speciation of major-to-ultratrace elements. Most of the elements in tea infusions were found to be present as associated complexes with large organic molecules. (author)

  16. ICP-AES determination of rare earths in zirconium with prior chemical separation of the matrix

    International Nuclear Information System (INIS)

    Rajeswari, B.; Dhawale, B.A.; Page, A.G.; Sastry, M.D.

    2002-01-01

    Zirconium being one of the most important material in nuclear industry used as a fuel cladding in reactors and an additive in advanced fuels necessitates its characterization for trace metallic contents. Zirconium, as refractory in nature as the rare earth elements, has a complex spectrum comprising of several emission lines. Rare earths, which are high neutron absorbers have to be analysed at very low limits. Hence, to achieve the desired limits, the major matrix has to be separated prior to rare earth determination. The present paper describes the method developed for the separation of rare earths from zirconium by solvent extraction using Trioctyl Phosphine Oxide (TOPO) as the extractant followed by their determination using Inductively Coupled Plasma - Atomic Emission Spectrometric (ICP-AES) method. Initially, radiochemical studies were carried out using known amounts of gamma active tracers of 141 Ce, 152-154 Eu, 153 Gd and 95 Zr for optimisation of extraction conditions using Tl- activated NaI detector. The optimum conditions at 0.5 M TOPO/xylene in 6 M HCl so as to achieve a quantitative recovery of rare earth analytes alongwith a near total extraction of zirconium in the organic phase, was further extended to carry out the studies using ICP-AES method. The recovery of rare earths was found to be quantitative within experimental error with a precision better than 10% RSD. (author)

  17. A new approach for the beryl mineral decomposition: elemental characterisation using ICP-AES and FAAS

    International Nuclear Information System (INIS)

    Nathan, Usha; Premadas, A.

    2013-01-01

    A new approach for the beryl mineral sample decomposition and solution preparation method suitable for the elemental analysis using ICP-AES and FAAS is described. For the complete sample decomposition four different decomposition procedures are employed such as with (i) ammonium bi-fluoride alone (ii) a mixture of ammonium bi-fluoride and ammonium sulphate (iii) powdered mixture of NaF and KHF 2 in 1: 3 ratio, and (iv) acid digestion treatment using hydrofluoric acid and nitric acid mixture, and the residue fused with a powdered mixture NaF and KHF 2 . Elements like Be, Al, Fe, Mn, Ti, Cr, Ca, Mg, and Nb are determined by ICP-AES and Na, K, Rb and Cs are determined by FAAS method. Fusion with 2g ammonium bifluoride flux alone is sufficient for the complete decomposition of 0.400 gram sample. The values obtained by this decomposition procedure are agreed well with the reported method. Accuracy of the proposed method was checked by analyzing synthetic samples prepared in the laboratory by mixing high purity oxides having a chemical composition similar to natural beryl mineral. It indicates that the accuracy of the method is very good, and the reproducibility is characterized by the RSD 1 to 4% for the elements studied. (author)

  18. A scheme for the complete elemental characterisation of brannerite mineral using ICP-AES

    International Nuclear Information System (INIS)

    Premadas, A.; Bose, Roopa

    2013-01-01

    Brannerite occurs along with other refractory minerals in pegmatite veins. Literature survey indicates lack of systematic and detailed chemical analysis procedure for brannerites. This paper report suitable sample decomposition procedures, yielding stable sample solution, suitable for the ICP-AES determination of major, minor and certain trace elements normally associated with brannerite mineral. Three different simple decomposition procedures such as (i) acid digestion (ii) fusion with lithium metaborate (iii) fusion with mixture of tetra sodium pyrophosphate and monosodium dihydrogen phosphate are used to obtain the sample solution for elemental analysis. In presence of higher concentrations of uranium and titanium, the major elements in brannerite mineral, a detailed study of the influence of uranium and titanium on ICP-AES determination of other elements, three commonly used emission lines of each element was carried out. The REEs, Y, Sc and Th have been determined after the removal of major matrix elements using oxalate precipitation. The accuracy of the proposed procedures is established by analyzing synthetic brannerite samples prepared by mixing high purity oxides or chlorides in a proportion similar to natural brannerite samples. The results indicate the method is accurate. The reproducibility studies carried out on one sample shows the % RSD varied from 2 to 5%. (author)

  19. The calibration of XRF polyethylene reference materials with k 0-NAA and ICP-AES

    International Nuclear Information System (INIS)

    Swagten, Josefien; Bossus, Daniel; Vanwersch, Hanny

    2006-01-01

    Due to the lack of commercially available polyethylene reference materials for the calibration of X-ray fluorescence spectrometers (XRF), DSM Resolve, in cooperation with PANalytical, prepared and calibrated such a set of standards in 2005. The reference materials were prepared based on the addition of additives to virgin polyethylene. The mentioned additives are added to improve the performance of the polymers. The elements present in additives are tracers for the used additives. The reference materials contain the following elements: F, Na, Mg, Al, Si, P, S, Ca, Ti and Zn in the concentration range of 5 mg/kg for Ti, up to 600 mg/kg for Mg. The calibration of the reference materials, including a blank, was performed using inductively coupled plasma atomic emission spectrometry (ICP-AES) and Neutron Activation Analysis (k 0 -NAA). ICP-AES was used to determine the elements Na, Mg, Al, P, Ca, Ti and Zn whereas k 0 -NAA was used for F, Na, Mg, Al, Ca, Ti and Zn. Over the complete concentration range, a good agreement of the results was found between the both techniques. This project has shown that within DSM Resolve, it is possible to develop and to calibrate homogenous reference materials for XRF

  20. Multielement determination of major-to-ultratrace elements in deep-seawater salts by ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Sakai, Takeshi; Nakagawa, Koji; Nakajima, Hiroshi; Itoh, Akihide; Ji, Shan; Haraguchi, Hiroki

    2002-01-01

    Major-to-ultratrace elements in deep-seawater salts were determined by ICP-AES and ICP-MS, after they were separated into the water-soluble, acid-soluble, and insoluble particle components. Deep-seawater salts were prepared from seawater collected at 344 m deep near the off-shore of Cape Muroto in Kochi Prefecture. The major and minor elements in salts were determined by ICP-AES after appropriate dilution with pure water. Trace and ultratrace elements in the water-soluble and acid-soluble components were preconcentrated by a chelating resin preconcentration method. In addition, the major to-ultratrace elements in the insoluble particle component were determined by ICP-AES and ICP-MS, after acid-digestion using HNO 3 /HF/HClO 4 . As a result, 21-35 elements in deep-seawater salts could be determined over the wide concentration range. It was found that the elements, such as Al, V, Fe, Mn, Co, Cu, Zn, and rare earth elements, were more abundant in the acid-soluble component of deep-seawater salts, which may play some essential roles in physiological effectiveness for intake of salt. (author)

  1. ICP-AES Determination of Mineral Content in Boletus tomentipes Collected from Different Sites of China.

    Science.gov (United States)

    Wang, Xue-mei; Zhang, Ji; Li, Tao; Li, Jie-qing; Wang, Yuan-zhong; Liu, Hong-gao

    2015-05-01

    P, Na, Ca, Cu, Fe, Mg, Zn, As, Cd, Co, Cr and Ni, contents have been examined in caps and stipes of Boletus tomentipes collected from different sites of Yunnan province, southwest China. The elements were determined using inductively coupled plasma atomic emission spectroscopy (ICP-AES) with microwave digestion. P, Ca, Mg, Fe, Zn and Cu were the most abundant amongst elements determined in Boletus tomentipes. The caps were richer in P, Mg, Zn and Cd, and the stipes in Ca, Co and Ni. Cluster analysis showed a difference between Puer (BT7 and BT8) and other places. The PCA explained about 77% of the total variance, and the minerals differentiating these places were P (PC1) together with Ca, Cu, Fe, Mg, As and Ni, Na (PC2) together with Cd, and Zn (PC3). The results of this study imply that element concentrations of a mushroom are mutative when collected from the different bedrock soil geochemistry.

  2. Elemental analysis of oum er rbia moroccan river-water Using icp-aes and chromatography

    International Nuclear Information System (INIS)

    Zahry, F.; Bounakhla, M.; Labraimi, M.; Moutte, J.; Bilal, E.

    2001-01-01

    The analysis of water and suspended particulate matter (SPM) from Oum er Rbia Moroccan river for the content of 22 elements has been performed utilizing ICP-AES and chromatography methods. MPS samples were dissolved in nitric acid. The element analyzed are : Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Br, Ba and Pb. The detection limits are sufficient for most of the elements to be determined. Results were assessed for the accuracy by the analysis of a multi-elemental standard. The results for most of the elements obtained were accurate to about 2-15%. The objective of the analysis were to determine the geochemical areas on this river, to explain the mechanisms of sediment transport and nevertheless, to assess the pollution of the river by human activities. 48 samples were collected along the river, between its source in meddle atlas and the Atlantic ocean at Azemour city

  3. Determination of platinum group metals by ICP-AES in environmental samples after preconcentration

    International Nuclear Information System (INIS)

    Vlasankova, R.; Sommer, L.

    1999-01-01

    Platinum group metal (PGM) may have toxic properties and their presence in the environment represent danger for human health. With the introduction of automobile catalytic converters containing PGM, the emission of these noble metals into atmosphere has increased. Platinum, palladium and rhodium are used in this catalytic converters to decrease toxic emissions of carbon monoxide, unburnt hydrocarbons and nitrogen oxides in vehicles exhaust gases. These catalysts are mobile sources of PGM into the environment. Thus, increased platinum concentrations have been found in various objects of environment because of the massive introduction of such catalytic converters are present. The preconcentration and separation of PGM and their determination by ICP-AES in environmental samples are described

  4. An ICP AES method for determination of dysprosium and terbium in high purity yttrium oxide

    International Nuclear Information System (INIS)

    Rupawate, V.H.; Hareendran, K.N.; Roy, S.B.

    2011-01-01

    High purity yttrium finds interesting application in astronavigation, luminescence, nuclear energy and metallurgical industries. Most of these applications require yttrium oxide of highest purity. Consequently there is a need for production of high purity yttrium oxide. Separation and purification of yttrium from other rare earths is a challenging task due to their close chemical properties. Liquid-liquid extraction and ion exchange have been widely used in the production of yttrium oxide of highest purity. Determination of impurities, especially other rare earths, in ppm level is required for process development and chemical characterization of the high purity Y 2 O 3 . Many methods have been described in literature. However since the advent of ICP AES much work in this area has been carried out by this technique. This paper describes the work done for determination of dysprosium (Dy) and terbium (Tb) in yttrium oxide using a high resolution sequential ICP AES. Emission spectra of rare earth elements are very complex and due to this complexity it is important to select spectral interference free analyte lines for determination of rare earths in rare earth matrix. For the determination of Dy and Tb in Y 2 O 3 , sensitive lines of Dy and Tb are selected from the instrument wavelength table and spectral interference free emission lines for the determination is selected by scanning around the selected wavelengths using 5 g/L Y solution and 5 mg/L standard solutions of Dy and Tb prepared in 4% nitric acid. It is found 353.170 nm line of Dy and 350.917 nm line Tb is suitable for quantitative determination. The signal to background ratio increases with increase in matrix concentration, i.e. from 1 to 5 mg/L. The optimum forward power is determined and it is found to be 1100W for Dy and 1000W for Tb. The instrument is calibrated using matrix matched standards containing 5g/L of Y matrix. Samples are dissolved in nitric acid and Y concentration is maintained at 5g/L. Two

  5. Multielement determination of major-to-ultratrace elements in vegetable samples by ICP-MS and ICP-AES after acid digestion

    International Nuclear Information System (INIS)

    Hokura, Akiko; Oguri, Sachiko; Matsuura, Hirotaka; Haraguchi, Hiroki

    2000-01-01

    A multielement determination of major-to-ultratrace elements in vegetable samples was carried out by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Spinach samples (0.5 g) were digested with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The decomposed samples were dissolved in a 1 M ( = mol dm -3 ) HNO 3 solution containing internal standard elements (Ge, In, and Re, 10 ppb each), and were subjected to multielement analyses by ICP-AES and ICP-MS. As a result, about 40 elements were successfully determined over a wide concentration range from % to ppb level. Spinach samples grown in different production areas were also analyzed in order to understand the influences of the environmental conditions on growth. Among the major and minor elements, the values of the coefficient of variance (CV) for B, Mg, P, and K were < 20%, and those for Ca, Na, Al, and Mn were higher than 50%. On the other hand, the values of CV for trace and ultratrace elements were significantly high. Furthermore, the present analytical method was also applied to the determination of major-to-ultratrace elements in various vegetable samples (23 species in 11 families); the similarities and differences of the elemental distributions in vegetables were found in the experimental results. (author)

  6. Multielement determination of major-to-ultratrace elements in vegetable samples by ICP-MS and ICP-AES after acid digestion

    Energy Technology Data Exchange (ETDEWEB)

    Hokura, Akiko; Oguri, Sachiko; Matsuura, Hirotaka; Haraguchi, Hiroki [Dept. of Applied Chemistry, Graduate School of Engineering, Nagoya Univ. (Japan)

    2000-06-01

    A multielement determination of major-to-ultratrace elements in vegetable samples was carried out by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Spinach samples (0.5 g) were digested with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The decomposed samples were dissolved in a 1 M ( = mol dm{sup -3}) HNO{sub 3} solution containing internal standard elements (Ge, In, and Re, 10 ppb each), and were subjected to multielement analyses by ICP-AES and ICP-MS. As a result, about 40 elements were successfully determined over a wide concentration range from % to ppb level. Spinach samples grown in different production areas were also analyzed in order to understand the influences of the environmental conditions on growth. Among the major and minor elements, the values of the coefficient of variance (CV) for B, Mg, P, and K were < 20%, and those for Ca, Na, Al, and Mn were higher than 50%. On the other hand, the values of CV for trace and ultratrace elements were significantly high. Furthermore, the present analytical method was also applied to the determination of major-to-ultratrace elements in various vegetable samples (23 species in 11 families); the similarities and differences of the elemental distributions in vegetables were found in the experimental results. (author)

  7. PIXE and ICP-AES comparison in evaluating the efficiency of metal extraction and analysis in aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Rugi, F.; Becagli, S.; Ghedini, C.; Marconi, M.; Severi, M.; Traversi, R.; Udisti, R. [Dep. of Chemistry, University of Florence, Sesto F.no (Fl) (Italy); Calzolai, G.; Chiari, M.; Lucarelli, F.; Nava, S. [Dep. of Physics and Astronomy , University of Florence and INFN, Sesto F. no (Fl) (Italy)

    2013-07-01

    Full text: A recent EU regulation (EN 149022005) requests the quantification of selected metals in the atmospheric particulate by mineralization with H{sub 2}0{sub 2} and HN0{sub 3} in microwave oven.This method might possibly conflict with the determination of the total metal content. In fact, the more the aerosol is enriched in crustal elements the more the difference in the two methods are expected, since the H{sub 2}0{sub 2}+ HN0{sub 3}, extraction is not reliable for metals in silicate form. In order to evaluate the extracted fraction, PIXE and ICP-AES measurements were carried out on the two halves of a series of PM10 and PM2.5 samples collected on Teflon filters in an urban site in the surrounding of Florence (Italy). An ICP-AES (Inductively Coupled Plasma -Atomic Emission Spectroscopy) method was optimized by an ultrasound nebuliser (CETAC 5000 AT+), in order to improve reproducibility and detection limit. In these conditions, it was possible quantifying AI, As, Cr, Cu, Fe, Mn, Ni, Pb and Vatsub-ppb levels. PIXE analysis using the external beam set-up at LABEC and a 3 MeV proton beam was carried out in order to measure the total elemental content of the metals. By comparing the ICP-AES and the PIXE results, a preliminary evaluation of the efficiency of the H{sub 2}0{sub 2} and HN0{sub 3} extraction method was performed. The obtained results (the mean values for the ICP-AES/PIXE ratio are reported in Table 1) show that the extraction procedure following the EN 14902 directive allows quantitative recoveries (80-120%, including the analytical uncertainties)for the majority of the analysed metals, especially for those mainly emitted by anthropic sources. This result points out that anthropic metals are present in the atmosphere as relatively available species (free metals, labile complexes, carbonates, oxides). On the contrary, lower recoveries were obtained for AI (mean value around 75%), a metal that has a relevant crustal fraction. Percentage of recovery of

  8. Comparative study for essential elements determination in milk products samples by INAA and ICP-AES

    International Nuclear Information System (INIS)

    Kira, Carmen S.; Maihara, Vera A.

    2002-01-01

    The mineral elements Ca, Fe, K, Mg, Na and Zn were analyzed in milk products by using instrumental neutron activation analysis (INAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The study included four types of cheese (mozzarella, minas, prato, parmesan), chocolate milk and yogurt. The samples were purchased from the local markets. Average concentrations ranged from 3668 (chocolate milk) to 16558 (parmesan cheese) mg/kg for Ca; from 2.61 (parmesan cheese) to 28.9 (chocolate milk) mg/kg for Fe; from 673 (mozzarella cheese) to 10492 (chocolate milk) mg/kg for K; from 398 (yogurt) to 2280 (minas cheese) mg/kg for Mg; from 1681 (yogurt) to 15248 (parmesan cheese) mg/kg for Na; from 12.1 (chocolate milk) to 71.8 (parmesan cheese) mg/kg for Zn. Two National Institute of Standards and Technology (NIST) standard reference materials (SRM 8435 Whole Milk Powder and SRM 1549 Non Fat Milk Powder) were analyzed to verify method accuracy. The statistic test used to determine the significance of the difference between the techniques was based on Unpaired t-Student test. Statistical test revealed no significance differences (P< 0,05) between the average values provided by the two methods for the most of determined elements. (author)

  9. Microwave assisted extraction for trace element analysis of plant materials by ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Borkowska-Burnecka, J. [Wroclaw Univ. (Poland). Inst. Chemii

    2000-11-01

    Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements. (orig.)

  10. Microwave assisted extraction for trace element analysis of plant materials by ICP-AES.

    Science.gov (United States)

    Borkowska-Burnecka, J

    2000-11-01

    Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements.

  11. PIXE and ICP-AES analysis of early glass unearthed from Xinjiang (China)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, B. [Department of Technical Physics, School of Physics, Peking University, Beijing 100871 (China); Cheng, H.S. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)]. E-mail: hscheng@fudan.edu.cn; Ma, B. [School of Information Science and Engineering, Fudan University, Shanghai 200433 (China); Li, Q.H. [Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Zhang, P. [Xinjiang Institute of Archaeology, Urumchi 830011 (China); Gan, F.X. [School of Information Science and Engineering, Fudan University, Shanghai 200433 (China); Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Yang, F.J. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)

    2005-10-15

    Early glasses (about 1066 BC-220 AD) unearthed from Xinjiang of China were chemically characterized by using PIXE and ICP-AES. It was found that these glasses were basically attributed to PbO-BaO-SiO{sub 2} system, K{sub 2}O-SiO{sub 2} system, Na{sub 2}O-CaO-SiO{sub 2} system and Na{sub 2}O-CaO-PbO-SiO{sub 2} system. The results from the cluster analysis showed that some glasses had basically similar recipe and technology. The PbO-BaO-SiO{sub 2} glass and the K{sub 2}O-SiO{sub 2} glass were thought to come from the central area and the south of ancient China, respectively. The part of the Na{sub 2}O-CaO-SiO{sub 2} glass (including the Na{sub 2}O-CaO-PbO-SiO{sub 2} glass) might be imported from Mesopotamia, while the other part might be locally produced.

  12. Estimation of boron, cadmium and cobalt at trace level in magnesium metal using ICP-AES method

    International Nuclear Information System (INIS)

    Patil, P.B.; Surya Prakash Rao, A.; Dixit, V.S.

    2002-01-01

    A method is established for the analysis of B, Cd and Co in the magnesium metal using ICP-AES technique in the range 1-50 ppm. Magnesium granules were dissolved in minimum amount of dilute nitric acid and the resultant solution is aspirated through ICP Nebulizer as nitrates Using various concentrations of matrix material 40, 20, 10 and 5 (mg/ml) were attempted to study the matrix effects on the above analytical elements. The optimum matrix concentration 20 mg/ml gave adequate detection limit of 1 ppm. The standard deviation of this method lies ∼ 1-3%. (author)

  13. Trace level determination of precious metals in aqueous medium, U, Th and Zr based nuclear materials by ICP-AES and EDXRF - a comparative study

    International Nuclear Information System (INIS)

    Sengupta, Arijit; Thulasidas, S.K.; Natarajan, V.

    2015-01-01

    A comparative study was carried out to determine Ag, Au and Pt in aqueous samples, uranium, zirconium, and thorium based nuclear fuels and associated materials by CCD based ICP-AES and EDXRF. In ICP-AES, the spectral interference of U, Th, Zr matrices on trace level determination of Ag, Au and Pt were studied for different analytical lines of these analytes. The analytical performance of different lines including detection limits, sensitivity, linear dynamic range etc were studied both by ICP-AES and EDXRF. Though EDXRF technique was known its non destructive nature, the overall analytical performance of ICP-AES technique was found to be superior to EDXRF. Based on the spectral contribution from emission rich matrix elements and the analytical performance of different analytical lines of these analytes, a method was developed for direct determination of these analytes by ICP-AES without chemical separation. The method was validated with synthetic samples and compared with EDXRF technique and conventional ICP-AES technique where the major matrix was chemically separated using suitable organic phase containing selective ligands. The ICP-AES method for direct determination of analytes without chemical separation was found to be simple, less time consuming, without generation of organic waste with acceptable analytical performance

  14. Nutritional and environmental properties of algal products used in healthy diet by INAA and ICP-AES

    International Nuclear Information System (INIS)

    Avino, P.; Lepore, L.; Carconi, P.L.; Moauro, A.

    2000-01-01

    Spirulina platensis alga sampled in the Caribbean Sea and seven other commercial algal products available on the Italian market of different origin and aspect, have been analyzed by instrumental neutron activation analysis (INAA) and inductively coupled plasma-atomic emission spectrometry (ICP-AES). By neutron irradiation and γ-ray spectrometry (INAA), as many as 20 elements could be measured instrumentally without any chemical treatment. Cu, Mg, Mn and Pb were determined after dissolution of the sample by ICP-AES. The cross-checking of the data, specifically by comparing those of Ca, Cr, Fe and Zn, obtained by the two techniques was found to be in good agreement. Special attention from analytical and nutritional point of view has been devoted to the toxic metals. The measurements have been carried out employing the reference algal material prepared by International Atomic Energy Agency (IAEA). (author)

  15. Method for separation of Cs from acid solution dissolving radionuclides and microanalysis of solution with ICP-AES

    International Nuclear Information System (INIS)

    Kanazawa, Toru; Hidaka, Akihide; Kudo, Tamotsu; Nakamura, Takehiko; Fuketa, Toyoshi

    2004-06-01

    The VEGA (Verification Experiments of radionuclides Gas/Aerosol release) program is being performed at JAERI to understand mechanisms of radionuclides release from irradiated fuel during severe accidents. As a part of evaluation in the program, the mass balances of released and deposited FP (Fission Products) onto the test apparatus are estimated from gamma ray measurement for acid solution leached from the apparatus, but short-life nuclides are difficult to be measured because those in the VEGA fuel have been mostly depleted due to cooling for several years. Moreover, the radionuclides without emitting gamma rays and very small quantity of elements cannot be quantified by gamma ray measurement. Therefore, a microanalysis by ICP-AES (Inductively Coupled Plasma - Atomic Emission Spectrometry) for the acid solution leached from VEGA apparatuses is being applied to evaluate the released and deposited masses for those elements. Since Cs-134 and -137, which are major FP dissolved in the solution, have high intensity of gamma ray spectrum, they have to be removed from the solution before the microanalysis in order to avoid contamination of ICP system and to decrease exposure to gamma ray. In this report, methods for separation of Cs from acid solution were reviewed and the applicability of them to the ICP-AES analysis was discussed. The method for Cs separation using the inorganic ion exchanger, AMP (Ammonium Molybdate Phosphate) was applied to the solutions of cold and hot test and the effectiveness was examined. The results showed that more than 99.9% of Cs could be removed from the test solutions, and once removed Sb by AMP was recovered by using a complexing agent such as citric acid. Next, the method was applied to an acid solution leached from VEGA-3 apparatus, and ICP-AES analysis was performed for it. The analysis showed that amount of U, Sr and Zr were successfully quantified. Most of elements to be analyzed were measurable except for Sb, Ag and Sn, although

  16. A study on the determination of phosphorus in Th-U matrix by a high resolution spectroanalyser (ICP-AES)

    International Nuclear Information System (INIS)

    Save, Neeta; Kumar, Neeraj; Jaiswal, Rajesh; Ghosh, Seema; Malav, R.K.; Das, D.K.; Prakash, Amrit; Behere, P.G.; Afzal, Mohd

    2013-01-01

    Phosphorus is present as an impurity in Thoria and constitutes an important chemical specification of the Thoria based fuel. The present paper depicts the importance of determination of phosphorus, which forms an important quality control step during the fabrication of mixed oxide (Th-U)O 2 pellet. A high resolution spectroanalyser using ICP-AES has been used for the determination of Phosphorus in (ThO 2 -3.25%UO 2 ). (author)

  17. Microwave digestion techniques applied to determination of boron by ICP-AES in BNCT program

    International Nuclear Information System (INIS)

    Farias, Silvia S.; Di Santo, Norberto R.; Garavaglia, Ricardo N.; Pucci, Gladys N.; Batistoni, Daniel A.; Schwint, Amanda E.

    1999-01-01

    Recently, boron neutron capture therapy (BNCT) has merged as an interesting option for the treatment of some kind of tumors where established therapies show no success. A molecular boronated species, enriched in 10 B is administrated to the subject; it localizes in malignant tissues depending the kind of tumor and localization. Therefore, a very important fact in BNCT research is the detection of boron at trace or ultra trace levels precisely and accurately. This is extremely necessary as boronated species do localize in tumoral tissue and also localize in liver, kidney, spleen, skin, membranes. By this way, before testing a boronated species, it is mandatory to determine its biodistribution in a statistically meaning population, that is related with managing of a great number of samples. In the other hand, it is necessary to exactly predict when to begin the irradiation and to determine the magnitude of radiation to obtain the desired radiological dose for a specified mean boron concentration. This involves the determination of boron in whole blood, which is related with boron concentration in the tumor object of treatment. The methodology selected for the analysis of boron in whole blood and tissues must join certain characteristics: it must not be dependant of the chemical form of boron, it has to be fast and capable to determine boron accurately and precisely in a wide range of concentrations. The design and validation of experimental models involving animals in BNCT studies and the determination of boron in blood of animals and subjects upon treatment require reliable analytical procedures to determine boron quantitatively in those biologic materials. Inductively coupled plasma-atomic emission spectrometry (ICP-AES) using pneumatic nebulization is one of the most promising methods for boron analysis, but the sample must be liquid and have low solid concentration. In our case, biological tissues and blood, it is mandatory to mineralize and/or dilute samples

  18. Comparision of ICP-OES and MP-AES in determing soil nutrients by Mechlich3 method

    Science.gov (United States)

    Tonutare, Tonu; Penu, Priit; Krebstein, Kadri; Rodima, Ako; Kolli, Raimo; Shanskiy, Merrit

    2014-05-01

    Accurate, routine testing of nutrients in soil samples is critical to understanding soil potential fertility. There are different factors which must be taken into account selecting the best analytical technique for soil laboratory analysis. Several techniques can provide adequate detection range for same analytical subject. In similar cases the choise of technique will depend on factors such as sample throughput, required infrastructure, ease of use, used chemicals and need for gas supply and operating costs. Mehlich 3 extraction method is widely used for the determination of the plant available nutrient elements contents in agricultural soils. For determination of Ca, K, and Mg from soil extract depending of laboratory ICP and AAS techniques are used, also flame photometry for K in some laboratories. For the determination of extracted P is used ICP or Vis spectrometry. The excellent sensitivity and wide working range for all extracted elements make ICP a nearly ideal method, so long as the sample throughput is big enough to justify the initial capital outlay. Other advantage of ICP techniques is the multiplex character (simultaneous acquisition of all wavelengths). Depending on element the detection limits are in range 0.1 - 1000 μg/L. For smaller laboratories with low sample throughput requirements the use of AAS is more common. Flame AAS is a fast, relatively cheap and easy technique for analysis of elements. The disadvantages of the method is single element analysis and use of flammable gas, like C2H2 and oxidation gas N2O for some elements. Detection limits of elements for AAS lays from 1 to 1000 μg/L. MP-AES offers a unique alternative to both, AAS and ICP-OES techniques with its detection power, speed of analysis. MP-AES is quite new, simple and relatively inexpensive multielemental technique, which is use self-sustained atmospheric pressure microwave plasma (MP) using nitrogen gas generated by nitrogen generator. Therefore not needs for argon and

  19. Tandem on-line continuous separations for atomic spectroscopic indirect analysis: iodide determination by ICP-AES

    International Nuclear Information System (INIS)

    Garcia, A.M.; Sanchez Uria, J.E.; Sanz-Medel, A.; Quintero Ortega, M.C.; Bautista, J.C.

    1992-01-01

    A sensitive and selective indirect determination of iodide by inductively coupled plasma emission spectrometry (ICP-AES) based on the principle of tandem on-line continuous separations as an alternative means of introducing samples into plasmas is proposed. Iodide is continuously extracted as an ion-pair into xylene by mixing the sample with Hg(II) and dipyridil solutions. The organic phase (containing the analyte in [Hg(Dipy) 2 ]I 2 form) is on-line continuously mixed with NaBH 4 (in DMF) and acetic acid solutions. Mercury vapour continuously generated from this organic phase is separated in a classical U-type gas-liquid separation device. The system has been optimized for the continuous extraction of KI, for the direct generation of cold mercury vapour from xylene and for the final ICP-AES determination of mercury. The optimised method has been applied to the determination of iodide (detection limit 20 ng/ml of iodide) in table salt and in synthetic samples. Very good agreement between found and certified results was observed. The usefulness and convenience of such alternative sample chemical pretreatment/presentation to the ICP is thus demonstrated for indirect determinations to be carried out by atomic spectroscopy methods. (authors)

  20. Evaluation of Wet Chemical ICP-AES Elemental Analysis Methods using Simulated Hanford Waste Samples-Phase I Interim Report

    International Nuclear Information System (INIS)

    Coleman, Charles J.; Edwards, Thomas B.

    2005-01-01

    The wet chemistry digestion method development for providing process control elemental analyses of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Melter Feed Preparation Vessel (MFPV) samples is divided into two phases: Phase I consists of: (1) optimizing digestion methods as a precursor to elemental analyses by ICP-AES techniques; (2) selecting methods with the desired analytical reliability and speed to support the nine-hour or less turnaround time requirement of the WTP; and (3) providing baseline comparison to the laser ablation (LA) sample introduction technique for ICP-AES elemental analyses that is being developed at the Savannah River National Laboratory (SRNL). Phase II consists of: (1) Time-and-Motion study of the selected methods from Phase I with actual Hanford waste or waste simulants in shielded cell facilities to ensure that the methods can be performed remotely and maintain the desired characteristics; and (2) digestion of glass samples prepared from actual Hanford Waste tank sludge for providing comparative results to the LA Phase II study. Based on the Phase I testing discussed in this report, a tandem digestion approach consisting of sodium peroxide fusion digestions carried out in nickel crucibles and warm mixed-acid digestions carried out in plastic bottles has been selected for Time-and-Motion study in Phase II. SRNL experience with performing this analytical approach in laboratory hoods indicates that well-trained cell operator teams will be able to perform the tandem digestions in five hours or less. The selected approach will produce two sets of solutions for analysis by ICP-AES techniques. Four hours would then be allocated for performing the ICP-AES analyses and reporting results to meet the nine-hour or less turnaround time requirement. The tandem digestion approach will need to be performed in two separate shielded analytical cells by two separate cell operator teams in order to achieve the nine-hour or less turnaround

  1. Monitoring of some heavy metal in egypt using different spectroscopic technique ICP-AES and AAS-GF

    International Nuclear Information System (INIS)

    El-Sayed, A.A.

    2005-01-01

    Heavy metals include both toxic and/or non toxic elements egyptian aquatic environment were monitored using inductivly coupled plasma-atomic emission spectroscopy; ICP-AES and graphite furnace-atomic absorption spectroscopy; GF-AAS. Water and aquatic weeds (waterhyathins) are of different categories specified for such monitoring form the canals. The locations of sampling sites the river nile in egypt. These sites were chosen based on the industrial activity comparing to the cleansite and the other cultivated one. Bioavailability and related effects were defined so as to specify actually the higher concentration more contaminated areas

  2. High-Activity ICP-AES Measurements in the ATALANTE Facility Applied to Analytical Monitoring of an Extraction Test

    Energy Technology Data Exchange (ETDEWEB)

    Esbelin, E.; Boyer-Deslys, V.; Beres, A.; Viallesoubranne, C. [CEA Marcoule, DEN/DRCP/SE2A/LAMM, BP17171, 30207 Bagnols-sur-Ceze (France)

    2008-07-01

    The Material Analysis and Metrology Laboratory (LAMM) of the Cea's Atalante complex ensures analytical monitoring of enhanced separation tests. Certain fission products, actinides and lanthanides were assayed by ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectroscopy) in the CBA shielded analysis line. These analyses were particularly effective for controlling the Diamex test, and contributed to its success. The Diamex process consists in extracting the actinides and lanthanides from a Purex raffinate using a diamide, DMDOHEMA, followed by stripping at low acidity. The major elements analyzed during the test were Am, Nd, Mo, Fe, and Zr.

  3. High-Activity ICP-AES Measurements in the ATALANTE Facility Applied to Analytical Monitoring of an Extraction Test

    International Nuclear Information System (INIS)

    Esbelin, E.; Boyer-Deslys, V.; Beres, A.; Viallesoubranne, C.

    2008-01-01

    The Material Analysis and Metrology Laboratory (LAMM) of the Cea's Atalante complex ensures analytical monitoring of enhanced separation tests. Certain fission products, actinides and lanthanides were assayed by ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectroscopy) in the CBA shielded analysis line. These analyses were particularly effective for controlling the Diamex test, and contributed to its success. The Diamex process consists in extracting the actinides and lanthanides from a Purex raffinate using a diamide, DMDOHEMA, followed by stripping at low acidity. The major elements analyzed during the test were Am, Nd, Mo, Fe, and Zr

  4. Multielement analytical procedure coupling INAA, ICP-MS and ICP-AES: Application to the determination of major and trace elements in sediment samples of the Bouregreg river (Morocco)

    International Nuclear Information System (INIS)

    Bounouira, H.; CEA - CNRS/UMR, Centre de Saclay, 91 - Gif sur Yvette; Choukri, A.; Hakam, O.K.; Cherkaoui, R.; Gaudry, A.; Delmas, R.; Mariet, C.; Chakiri, S.

    2008-01-01

    Instrumental neutron activation analysis (INAA), inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) were used for the determination of major and trace elements in sediment samples of the Bouregreg river (Morocco). The reliability of the results was checked, by using IAEA Soil-7 certified reference material. Results obtained by the three techniques were compared to control digestions efficiencies. A general good agreement was found between INAA and both ICP-MS and ICP-AES after alkaline fusion (ICPf). The ICP-MS technique used after acid attack (ICPa) was satisfactory for a few elements. A principal component analysis (PCA) has been used for analyzing the variability of concentrations, and defining the most influential sites with respect to the general variation trends. Three groups of elements could be distinguished. For these groups a normalization of concentrations to the central element concentration (that means Mn, Si or Al) is proposed. (author)

  5. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    International Nuclear Information System (INIS)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario; Pena, Rosa M.; Herrero, Carlos

    2008-01-01

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L -1 for Na, -1 for K, 0.02-4.83 mg L -1 for Mg content, -1 for Cu and 0.03-13.10 mg L -1 for Ca

  6. Chemical characterization of airborne particulate matter in ambient air of Nagoya, Japan, as studied by the multielement determination with ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Fukai, Taku; Kobayashi, Tatsuya; Sakaguchi, Masahiro; Aoki, Masanori; Saito, Tsuyoshi; Fujimori, Eiji; Haraguchi, Hiroki

    2007-01-01

    The multielement determination of PM 10 (airborne particulate matter smaller than 10 μm) samples, which was collected by a high volume air sampler at the urban site of Nagoya City, was carried out by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The present analytical method was validated by analyzing urban particulate matter standard reference material of NIST SRM 1648. The analytical data for ca. 30 elements in PM 10 samples collected during a period from 8 September to 9 October, 2003, were obtained in the concentration range from sub-μg g -1 to several-10 mg g -1 , but the data for 18 elements among ca. 30 elements were available for the characterization of PM 10 samples in ambient air, because of problems caused by the filter blanks. Then, the trends concerning the distributions of diverse elements in PM 10 samples were analyzed based on the enrichment factors and size distribution factors. The lithophile and siderophile elements were distributed more than 50% in coarse particle fraction (>2.1 μm), which was derived mainly from natural sources, such as soils and crustal minerals. On the other hand, chalcophile elements were distributed more than 50% in fine particle fraction ( 10 samples as well as their mining influence factors (MIFs) suggested their wide use in industrial productions. (author)

  7. Determination of Al of Sucralfate in Stomachs by ICP-AES%ICP-AES测定大鼠胃内硫糖铝中的铝

    Institute of Scientific and Technical Information of China (English)

    李艳; 朱照静

    2009-01-01

    采用干法灰化,电感耦合等离子体-原子发射光谱法(ICP-AES)测定正常大鼠胃内硫糖铝中的铝量.结果表明,最佳分析波长为396.153nm,检出限为8ng·mL-1,各组内相对标准偏差均小于0.81%,组间相对标准偏差均小于13.4%,铝的回收率在96.0%-99.5%之间,表明ICP-AES测定大鼠胃内硫糖铝中铝的精密度、准确度良好,满足生物样品分析要求.大鼠灌服硫糖铝6h后胃内的铝基本排空,与正常胃排空时间一致,表明硫糖铝中的铝对正常胃粘膜无枯附作用.

  8. Determination of aluminium in groundwater samples by GF-AAS, ICP-AES, ICP-MS and modelling of inorganic aluminium complexes.

    Science.gov (United States)

    Frankowski, Marcin; Zioła-Frankowska, Anetta; Kurzyca, Iwona; Novotný, Karel; Vaculovič, Tomas; Kanický, Viktor; Siepak, Marcin; Siepak, Jerzy

    2011-11-01

    The paper presents the results of aluminium determinations in ground water samples of the Miocene aquifer from the area of the city of Poznań (Poland). The determined aluminium content amounted from aluminium determinations were performed using three analytical techniques: graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The results of aluminium determinations in groundwater samples for particular analytical techniques were compared. The results were used to identify the ascent of ground water from the Mesozoic aquifer to the Miocene aquifer in the area of the fault graben. Using the Mineql+ program, the modelling of the occurrence of aluminium and the following aluminium complexes: hydroxy, with fluorides and sulphates was performed. The paper presents the results of aluminium determinations in ground water using different analytical techniques as well as the chemical modelling in the Mineql+ program, which was performed for the first time and which enabled the identification of aluminium complexes in the investigated samples. The study confirms the occurrence of aluminium hydroxy complexes and aluminium fluoride complexes in the analysed groundwater samples. Despite the dominance of sulphates and organic matter in the sample, major participation of the complexes with these ligands was not stated based on the modelling.

  9. Multielement determination of major-to-ultratrace elements in plant reference materials by ICP-AES/ICP-MS and evaluation of their enrichment factors

    International Nuclear Information System (INIS)

    Hokura, Akiko; Matsuura, Hirotaka; Katsuki, Fumie; Haraguchi, Hiroki

    2000-01-01

    The multielement determination of major-to-ultratrace elements in plant reference materials (SRM Pine Needles, SRM Tomato Leaves, and NIES Tea Leaves) was carried out by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry). The plant sample was decomposed with nitric acid and hydrofluoric acid in a Teflon beaker on a hot plate. The digest was dissolved in 1 M HNO 3 solution, and then subjected to elemental analyses. As a consequence, the analytical data for about 40 elements including rare earth elements (REEs) were obtained over a wide concentration range, for example, from 49600 μg g -1 of Ca to 6.2 ng g -1 of Lu in Tomato Leaves. The enrichment factors, which were estimated by normalizing the observed concentrations of analyte elements in plant reference materials to their soil abundances, were evaluated in order to discuss the relative abundances of various elements between plants and soil. It was found that most of the elements, except for REEs in Pine Needles and Tea Leaves, were significantly accumulated in the plant reference materials. In particular, the essential elements (K, Mg, Ca, Mn, Cu, Zn, B and P) for plant growth provided large enrichment factors. (author)

  10. A comparison between PIXE and ICP-AES measurements of metals in aerosol particulate collected in urban and marine sites in Italy

    Energy Technology Data Exchange (ETDEWEB)

    Traversi, R.; Becagli, S. [Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia 3, I-50019 Sesto F.no, Florence (Italy); Calzolai, G.; Chiari, M.; Giannoni, M. [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Lucarelli, F., E-mail: lucarelli@fi.infn.it [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Nava, S. [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Rugi, F.; Severi, M.; Udisti, R. [Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia 3, I-50019 Sesto F.no, Florence (Italy)

    2014-01-01

    PIXE and ICP-AES techniques are largely used in atmospheric aerosol studies. Since PIXE is able to provide the total elemental concentrations, while ICP-AES results depend on the extraction conditions, parallel PIXE and ICP-AES measurements of Fe, Al, Cu, Pb, Mn, Cr, Ni, V, As on PM10 and PM2.5 samples were compared. Two extraction procedures were applied to samples from 5 sites at different anthropization level in Italy: a “weak” extraction (HNO{sub 3} at pH = 1.5) and a “strong” extraction (micro-wave oven in HNO{sub 3} and H{sub 2}O{sub 2} – following EU rules). The amount of the metal extracted in the different conditions resulted to be strongly dependent on the sampling site, on the main sources of the particle (crustal or anthropic) containing the metal and on the sampled size class.

  11. Zinc, lead and copper in human teeth measured by induced coupled argon plasma atomic emission spectroscopy (ICP-AES)

    Energy Technology Data Exchange (ETDEWEB)

    Chew, L.T.; Bradley, D.A. E-mail: D.A.Bradley@exeter.ac.uk; Mohd, Y.; Jamil, M

    2000-11-15

    Inductively Coupled Argon Plasma Atomic Emission Spectroscopy (ICP-AES) has been used to determine Pb, Zn and Cu levels in 47 exfoliated human teeth (all of which required extraction for orthodontic reasons). Lead concentrations for the group were 1.7 {mu}g (g tooth mass){sup -1} to 40.5 {mu}g (g tooth mass){sup -1}, with a median of 9.8 {mu}g (g tooth mass){sup -1}. A median lead level in excess of the group value was found for the teeth of six lorry drivers who were included in the study. A more significant enhancement was found for the seven subjects whose age was in excess of 60 years. The median values for Zn and Cu were 123.0 and 0.6 {mu}g (g tooth mass){sup -1} respectively. Present values for tooth-Zn are lower than published data for other ethnic groups.

  12. An inductively coupled plasma atomic emission spectrometric (ICP-AES) determination of boron and other trace impurities in aluminium metal

    International Nuclear Information System (INIS)

    Deshpande, S.S.; Patil, P.B.; Karanjikar, N.P.

    2002-01-01

    The optimisation and use of ICP-AES technique for the analysis of aluminium metal for B, Cr, Cu, Fe, Mg, Mn, Ni, Si, Ti, V and Zn in the concentration range 5.0 to 50.0 ppm is described. The method involves the dissolution of aluminium metal in acqua-regia. The matrix aluminium solution (2mg/ml) is mixed with composite impurity solution in proper proportions, for getting the required set of standards. JY 1 metre Czerny-Turner Scanning monochromator is used to measure peak intensities corresponding to each analyte wavelength selected. The mean relative standard deviation (RSD) of the method for various elements is found to be 4.0% -2.0% in the concentration range studied. (author)

  13. ICP-AES method for metals in air. Pt 2 - analysis; final report on project R48113

    International Nuclear Information System (INIS)

    Taylor, C.; Howe, A.

    2002-04-01

    An ICP-AES instrument operating procedure has been drafted and incorporated in ISO 15202-3 Workplace air - Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry: Part 3 - Analysis. It is expected that this International Standard will be published during 2003. The performance of the analytical method described ISO 15202-3 was evaluated by carrying out laboratory experiments to determine analytical precision. The uncertainty associated with analytical variability was then combined with other sources of uncertainty arising from the sampling method described in ISO 15202-1. A first draft of a proposed new MDHS on Metals and metalloids in workplace air by Inductively Coupled Plasma Atomic Emission Spectrometry has been prepared based on ISO 15202-1, ISO 15202-2 and ISO 15202-3. It is expected that this will be published in late 2002 or early 2003

  14. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Pena, Rosa M. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: qarosa@lugo.usc.es; Herrero, Carlos [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: cherrero@lugo.usc.es

    2008-10-17

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L{sup -1} for Na,

  15. Determination of 11 trace elements in U3O8 CRMs by ICP-AES

    International Nuclear Information System (INIS)

    Liu Husheng

    1994-01-01

    The TBP extractant-containing resin and extraction chromatography technique were used to separate 11 trace elements in U 3 O 8 CRMs. The sample was separated at a flow rate of 0.5 mL/min with 3 mol/L HNO 3 as medium. A model 975 ICP direct reading spectrometer was used to determine the trace elements of Ca, Cd, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Pb and Sn in U 3 O 8 CRMs. The lowest quantitatively determinable concentration of impurities in U 3 O 8 CRMs are 0.02-1.6 μg/g. The RSD is less than 10%. The proposed method provides excellent and accurate analytical data for the U 3 O 8 samples prepared as certified reference materials (CRMs)

  16. Determination of trace elements in ceramic uranium dioxide pellets powders CRMs by ICP-AES

    International Nuclear Information System (INIS)

    Liu Husheng; Li Jun

    1997-01-01

    The 237-quaternary ammonium extraction resin chromatography is used to the separation of 6 trace elements in ceramic uranium dioxide pellets powders, which are used as certified reference materials (CRMs). The sample is dissolved in 6.5 mol/L HNO 3 and uranium is separated by chromatographic column. the 6 trace elements Al, Ba, Co, Ta, Ti and V contained in the elutriant are determined by using ICP directly reading spectrometer. For a 300 mg sample, the lowest determinable concentration of impurities in ceramic UO 2 pellets powders CRMs is (0.016-0.250) x 10 -6 . The relative standard deviation is less than 7.5%. The proposed method provides excellent and accurate analytical data for the ceramic UO 2 pellets powders samples (CRMs)

  17. Determination of the performance characteristics of a method for the measurement of total phosphorus in groundwater with the PE Optima 3000 XL ICP-AES

    NARCIS (Netherlands)

    Kohlmeyer U; Breugem PM; Boer JLM de; LAC

    1996-01-01

    Dit rapport behandelt de prestatiekenmerken van een methode voor de bepaling van totaal-fosfor in grondwater met behulp van ICP-AES met een axiaal plasma (Perkin-Elmer Optima 3000 XL). Met de reeds bestaande methode 'TotP' werden de volgende prestatiekenmerken vastgesteld:

  18. Neutron activation analysis and ICP-AES to determine metal traces in antarctic krill. CNEA laboratories participation in the certification of a reference material

    International Nuclear Information System (INIS)

    Smichowski, Patricia N.; Farias, Silvia S.; Resnizky, Sara M.; Marrero, Julieta G.

    1999-01-01

    For the international certification of a reference material based on krill, As and Hg were determined by instrumental neutron activation analysis and Br, Co and Se by radiochemical neutron activation analysis. Inductive coupling plasma atomic emission spectrometry (ICP-AES) was used to determine Cu, Fe, Mn, and Zn. The results, which are in good agreement with those obtained by other laboratories, are discussed

  19. Preconcentration of uranium, thorium, zirconium, titanium, molybdenum and vanadium with oxine supported on microcrystalline naphthalene and their determinations by ICP-AES

    International Nuclear Information System (INIS)

    Kumar, Naveen; Kumar, Sanjay; Kumar, Vijay; Nandakishore, S.S.; Bangroo, P.N.

    2013-01-01

    As an effective technique for separation and preconcentration of trace elements, solid-liquid extraction with microcrystalline naphthalene has received great attention in recent years. The application of the adsorption of the metal complexes on microcrystalline naphthalene has greatly enhanced the utility of solid-liquid extraction in trace analysis. A survey of the literature revealed that single element detection techniques such as spectrophotometry, atomic absorption spectrometry, and polarography were mostly combined with this separation method. However, multi-element simultaneous detection techniques, like ICP-AES and ICP-MS were seldom used as the detectors in this solid-liquid extraction method. The aim of this work was to attempt to adopt the reagent oxine for the separation and subsequent determination of U, Th, Zr, Ti, Mo and V by ICP-AES, after adsorption of their oxinate complexes on microcrystalline naphthalene

  20. Determination of some inorganic metals in edible vegetable oils by inductively coupled plasma atomic emission spectroscopy (ICP-AES

    Directory of Open Access Journals (Sweden)

    Musa Özcan, M.

    2008-09-01

    Full Text Available Seventeen edible vegetable oils were analyzed spectrometrically for their metal (Cu, Fe, Mn, Co, Cr, Pb, Cd, Ni, and Zn contents. Toxic metals in edible vegetable oils were determined by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES. The highest metal concentrations were measured as 0.0850, 0.0352, 0.0220, 0.0040, 0.0010, 0.0074, 0.0045, 0.0254 and 0.2870 mg/kg for copper in almond oil, for iron in corn oil-(c, for manganese in soybean oil, for cobalt in sunflower oil-(b and almond oil, for chromium in almond oil, for lead in virgin olive oil, for cadmium in sunflower oil-(e, for nickel almond oil and for zinc in almond oil respectively. The method for determining toxic metals in edible vegetable oils by using ICP-AES is discussed. The metals were extracted from low quantities of oil (2-3 g with a 10% nitric acid solution. The extracted metal in acid solution can be injected into the ICPAES. The proposed method is simple and allows the metals to be determined in edible vegetable oils with a precision estimated below 10% relative standard deviation (RSD for Cu, 5% for Fe, 15% for Mn, 8% for Co, 10% for Cr, 20% for Pb, 5% for Cd, 16% for Ni and 11% for Zn.En este estudio se analizó espectrométricamente el contenido en metales (Cu, Fe, Mn, Co, Cr, Pb, Cd, Ni, and Zn de 17 aceites vegetales comestibles mediante ICP-AES. Las concentaciones más elevadas se encontraron para el cobre en el aceite de almendra (0.0850 mg/kg, para el hierro en el aceite de maiz(c,(0.0352 mg/kg, para el manganeso en el aceite de soja (0.0220 mg/kg, para el cobalto en el aceite de girasol (b (0.0040 mg/kg, para el cromo en el aceite de almendra (0.0010 mg/kg, para el plomo en el aceite de oliva virgen (0.0074 mg/kg, para el cadmio en el aceite de girasol (e (0.0045 mg/kg, para el niquel en el aceite de almendra (0.0254 mg/kg y para el zincen el aceite de almendra (0.2870 mg/kg. Los metales se extrajeron a partir de bajas cantidades de aceite (2-3 g, con

  1. A windows based automated quality control system for the ICP-AES analysis of Waste Isolation Pilot Plant (WIPP) brines

    International Nuclear Information System (INIS)

    Gerth, D.J.

    1996-01-01

    High sample volume analytical laboratories typically require automation of tasks to maximize efficiency and productivity. Typical approaches target instrument operation and data reporting (LIMS), but frequently ignore the data evaluation and run time QC aspects. Automation of these steps can save up to 50% of the time it takes to analyze, evaluate, and report data from a typical ICP-AES run. The program developed in this project addresses this need by performing a CLP-style evaluation of the run time QC data included in an instrument run. Written in Microcraft Visual Basic 3.0, it makes use of a Microsoft Access database to store method parameters and QC sample results for control charting. In operation, the analyst enters method background data (e.g., control samples types and acceptance criteria for each analyte), which is then stored in the method database. Once the method parameters are entered, instrument data files may be imported for review. Upon import, the run is automatically checked against desired QC criteria, QC sample data are added to the database, and failing samples flagged appropriately. Analytes passing all QC checks are flagged for upload to the laboratory LIMS. The analyst may then review the run sample by sample, and, if desired, override the computer upload flag. An exception report may be generated detailing samples that require reanalysis

  2. [Analysis of inorganic elements in hydroponic Taraxacum mongolicum grown under different spectrum combinations by ICP-AES].

    Science.gov (United States)

    Chen, Xiao-li; Morewane, M B; Xue, Xu-zhang; Guo, Wen-zhong; Wang, Li-chun

    2015-02-01

    Dandelion (Taraxacum mongolicum) was hydroponically cultured in a completely enclosed plant factory, in which fluorescence and LED emitting spectra of different bands were used as the sole light source for plant growth. Effects of spectral component on the growth of dandelion were studied and the contents of ten inorganic elements such as K, P, Ca, Mg, Na, Fe, Mn, Zn, Cu and B in dandelion were analyzed by ICP-AES technology. The results showed that: (1) Under the condition of similar photosynthetic active radiation (PAR), single R or combined spectrums of FLRB were beneficial for biomass accumulation, while single B was the contrary; (2) Macroelements content ratio in Taraxacum mongolicum grown under FLwas K:Ca:P:Mg : Na=79.74:32.39:24.32:10.55:1.00, microelements content ratio was Fe:Mn:B:Zn:Cu = 9.28:9.71:3.82:2.08:1.00; (3) Red light (peak at 660 nm) could promote the absorptions of Ca, Fe, Mn, Zn, while absorption of Cu was not closely related to spectral conditions; (4) Thehighest accumulation of Ca, Na, Mn and Zn were obtained in aerial parts of Taraxacum mongolicum plants grown under pure red spectrum R, while the accumulation of the rest six elements reached the highest level under the mixed spectrum FLRB.

  3. A determination method of Ru, Rh and Pd in high-level liquid waste (HLLW) by cation exchange separation and ICP-AES measurement

    International Nuclear Information System (INIS)

    Cao Desheng; Duan Shirong; Qin Fengzhou; Li Jinying; Zhang Huaili

    1992-01-01

    The authors describe a determination method of Ru, Rh and Pd in HLLW with cation-exchange separation and ICP-AES measurement. A sample of HLLW was treated with the hydrochloride acid containing enough sodium chloride, then passed through a strongly acidic cation-exchange resin column, the Ru, Rh and Pd as chloro-complexes go to the eluate while the interference elements are absorbed on the resins in the column. The Ru, Rh and Pd are collected and determined by ICP-AES. The obtained results show that the recovery is 90% and the relative standard deviation is 6% as the Ru content within the range (35-230) x 10 -6 ; the recovery is 106% and RSD is 10% as the Rh content within (2-20) x 10 -6 ; and the recovery of Pd is 72% as its content less than 2 x 10 -6

  4. Separation, preconcentration and estimation of rare earth and trace elements by inductively coupled plasma-atomic emission spectrometry (ICP-AES) in thorium matrices

    International Nuclear Information System (INIS)

    Chakraborty, Prithwish; Kumar Vijay; Durani, Smeer; Satyanarayana, K.

    2007-01-01

    A simple, sensitive and efficient method is developed for the separation of Rare earth elements (REEs) La-Lu, and Y and some trace elements Cd, Co, Cr, Cu, Ni,V, Zn from thorium matrix and their subsequent estimations by ICP-AES. In thorium-rich geological samples, the estimation of REE's by ICP-AES suffers from the spectral interferences due to the presence of excess of Th. In the proposed method, thorium is separated from the matrix by the solvent extraction. To optimize the separation, of REEs and trace elements from Th matrix, synthetic mixture solutions was prepared containing Th, REEs and trace elements maintaining different acidic conditions (1M, 2M, 4M, 6M, 8M and 10M HNO 3 and 2M, 4M, 6M and 8M HCl) and each solution was subjected to solvent extraction. The solvent extraction was carried out using a mixture of di-2-ethylhexyl phosphoric acid (in 30 % Toluene) and 1- pentanol in the ratio of 5:1. The aqueous phase containing the required elements was evaporated to dryness and an acidity of 5% HCl is maintained in final volume. Solutions were analysed by ICP-AES and the quantitative recovery of REEs and trace elements were obtained at 6M HNO 3 acidity. The developed method was applied to the certified standard reference material: IGS-36 and the values obtained were comparable with the certified values. The method was also applied to the real time monazite sample and the recovery was quantitative. Corrections have been applied for the REEs inter-elemental interferences in ICP-AES. (author)

  5. Multielement determination and speciation of major-to-trace elements in black tea leaves by ICP-AES and ICP-MS with the aid of size exclusion chromatography

    International Nuclear Information System (INIS)

    Matsuura, Hirotaka; Hokura, Akiko; Katsuki, Fumie; Itoh, Akihide; Haraguchi, Hiroki

    2001-01-01

    A multielement determination of major-to-trace elements in black tea leaves and their tea infusions was carried out by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry). Tea infusions were prepared as usual tea beverage by brewing black tea leaves in boiling water for 5 min. About 40 elements in tea leaves and tea infusions could be determined over the wide concentration range in 8 orders of magnitude. The extraction efficiency of each element was estimated as the ratio of its concentration in tea infusions to that in tea leaves. From the experimental results for the extraction efficiencies, the elements in black tea leaves were classified into three characteristic groups: (i) highly-extractable elements (>55%): Na, K, Co, Ni, Rb, Cs and Tl, (ii) moderately-extractable elements (20-55%): Mg, Al, P, Mn and Zn, and (iii) poorly-extractable elements (<20%): Ca, Fe, Cu, Sr, Y, Zr, Mo, Sn, Ba and lanthanoid elements. Furthermore, speciation of major-to-trace elements in tea infusions was performed by using a combined system of size exclusion chromatography (SEC) and ICP-MS (or ICP-AES). As a result, many diverse elements were found to be present as complexes associated with large organic molecules in tea infusions. (author)

  6. Comparison of MP AES and ICP-MS for analysis of principal and selected trace elements in nitric acid digests of sunflower (Helianthus annuus).

    Science.gov (United States)

    Karlsson, Stefan; Sjöberg, Viktor; Ogar, Anna

    2015-04-01

    The use of nitrogen as plasma gas for microwave plasma atomic emission spectroscopy (MP AES) is an interesting development in analytical science since the running cost can be significantly reduced in comparison to the inductively coupled argon plasma. Here, we evaluate the performance of the Agilent 4100 MP AES instrument for the analysis of principal metals (Ca, K, Mg, and Na), lithogenic metals (Al, Fe, and Mn) and selected trace metals (As, Ba, Cd, Co, Cr, Cu, Mo, Ni, Pb, V, and Zn) in nitric acid plant digests. The digests were prepared by microwave-assisted dissolution of dry plant material from sunflower (Helianthus annuus) in concentrated nitric acid. Comparisons are made with analysis of the same solutions with ICP-MS (Agilent 7500cx) using the octopole reaction system (ORS) in the collision mode for As, Fe, and V. The limits of detection were usually in the low µg L(-1) range and all principal and lithogenic metals were successfully determined with the MP AES and provided almost identical results with the ICP-MS. The same applies for the selected trace metals except for As, Co and Mo where the concentrations were below the detection limit with the MP AES. For successful analysis we recommend that (i) only atom lines are used, (ii) ionization is minimized (e.g. addition of CsNO3) and (iii) the use of internal standards should be considered to resolve spectral interferences. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Construcción y caracterización de un nuevo nebulizador múltiple para técnicas analíticas basadas en plasma (ICP-OES, ICP-MS y MP-AES).

    OpenAIRE

    Lúñez Fernández, Claudia

    2016-01-01

    En la siguiente memoria, se presenta la metodología para la construcción de un nuevo nebulizador múltiple, resultado de una serie de nebulizadores anteriores, los cuales se han ido mejorando para optimizar las características del aerosol generado y con ello los parámetros analíticos de calidad en la espectrometría de emisión atómica con plasma de microondas (MP-AES) y espectrometría de emisión óptica con plasma de acoplamiento inductivo (ICP-OES). Este nuevo nebulizador multiconducto presenta...

  8. Geographical traceability of wild Boletus edulis based on data fusion of FT-MIR and ICP-AES coupled with data mining methods (SVM).

    Science.gov (United States)

    Li, Yun; Zhang, Ji; Li, Tao; Liu, Honggao; Li, Jieqing; Wang, Yuanzhong

    2017-04-15

    In this work, the data fusion strategy of Fourier transform mid infrared (FT-MIR) spectroscopy and inductively coupled plasma-atomic emission spectrometry (ICP-AES) was used in combination with Support Vector Machine (SVM) to determine the geographic origin of Boletus edulis collected from nine regions of Yunnan Province in China. Firstly, competitive adaptive reweighted sampling (CARS) was used for selecting an optimal combination of key wavenumbers of second derivative FT-MIR spectra, and thirteen elements were sorted with variable importance in projection (VIP) scores. Secondly, thirteen subsets of multi-elements with the best VIP score were generated and each subset was used to fuse with FT-MIR. Finally, the classification models were established by SVM, and the combination of parameter C and γ (gamma) of SVM models was calculated by the approaches of grid search (GS) and genetic algorithm (GA). The results showed that both GS-SVM and GA-SVM models achieved good performances based on the #9 subset and the prediction accuracy in calibration and validation sets of the two models were 81.40% and 90.91%, correspondingly. In conclusion, it indicated that the data fusion strategy of FT-MIR and ICP-AES coupled with the algorithm of SVM can be used as a reliable tool for accurate identification of B. edulis, and it can provide a useful way of thinking for the quality control of edible mushrooms. Copyright © 2017. Published by Elsevier B.V.

  9. Geographical traceability of wild Boletus edulis based on data fusion of FT-MIR and ICP-AES coupled with data mining methods (SVM)

    Science.gov (United States)

    Li, Yun; Zhang, Ji; Li, Tao; Liu, Honggao; Li, Jieqing; Wang, Yuanzhong

    2017-04-01

    In this work, the data fusion strategy of Fourier transform mid infrared (FT-MIR) spectroscopy and inductively coupled plasma-atomic emission spectrometry (ICP-AES) was used in combination with Support Vector Machine (SVM) to determine the geographic origin of Boletus edulis collected from nine regions of Yunnan Province in China. Firstly, competitive adaptive reweighted sampling (CARS) was used for selecting an optimal combination of key wavenumbers of second derivative FT-MIR spectra, and thirteen elements were sorted with variable importance in projection (VIP) scores. Secondly, thirteen subsets of multi-elements with the best VIP score were generated and each subset was used to fuse with FT-MIR. Finally, the classification models were established by SVM, and the combination of parameter C and γ (gamma) of SVM models was calculated by the approaches of grid search (GS) and genetic algorithm (GA). The results showed that both GS-SVM and GA-SVM models achieved good performances based on the #9 subset and the prediction accuracy in calibration and validation sets of the two models were 81.40% and 90.91%, correspondingly. In conclusion, it indicated that the data fusion strategy of FT-MIR and ICP-AES coupled with the algorithm of SVM can be used as a reliable tool for accurate identification of B. edulis, and it can provide a useful way of thinking for the quality control of edible mushrooms.

  10. ICP-AES determination of rare earth elements in coal fly ash samples of thermal power stations: assessment of possible recovery and environmental impact of rare earth elements

    International Nuclear Information System (INIS)

    Premadas, A.; Mary, Thomas Anitha; Chakrapani, G.

    2013-01-01

    Accurate determination of rare earth elements (REEs) in ashes of thermal power plants is important in the current scenario due to its economic value, and the pollution caused if they are released in to the environment. Their toxicity to living organisms now gaining importance in international community, and some investigation shows it causes retardation in plant growth. In coal based thermal stations huge quantity of coal used annually as a fuel and lakhs of tones of waste is generated in the form of ashes. Therefore studies were carried out on three aspects - fairly rapid and accurate ICP-AES determination REEs in coal fly ash samples using addition technique, a preliminary acid leaching studies on coal received from three different fired thermal power stations using hydrochloric acid at pH 1 and 2, and quantify the REEs leached, and economic recovery of REEs using di-(2-ethylhexyl) phosphoric acid solvent extraction process or precipitation hydroxides using dilute ammonia solution. The standard addition method of REEs determination using rate and reproducible values, besides the analysis is fast compared to the ion exchange separation of REEs followed by the ICP-AES determination. (author)

  11. Qualitative and quantitative analysis of human nails to find correlation between nutrients and vitamin D deficiency using LIBS and ICP-AES.

    Science.gov (United States)

    Almessiere, M A; Altuwiriqi, R; Gondal, M A; AlDakheel, R K; Alotaibi, H F

    2018-08-01

    In this work, we analysed human fingernails of people who suffer from vitamin D deficiency using the laser-induced breakdown spectroscopy(LIBS) and inductively coupled plasma atomic emission spectroscopy (ICP-AES)techniques. The measurements have been conducted on 71 nail samples collected randomly from volunteers of different genders and ages ranged between 20 and 50 years. The main aim of this study is to find the correlation between vitamin D deficiency and the intensity of some dominated lines in the LIBS spectra. A LIBS spectrum consists of dominant lines of fifteen elements including calcium, magnesium, sodium, potassium, titanium, iron, chloride, sulphur, copper, chromium, zinc, nitrogen, phosphor, and oxygen. By recording the spectrum in specific ranges and focusing on calcium, magnesium, sodium, and potassium, we found a correlation between the intensity of the potassium (K) lines at (766.5 and 769.9 nm)and vitamin D level in both age groups (20 and 25 years old), with weak correlation for the calcium (Ca), magnesium (Mg), and sodium (Na) lines. To verify the validity of the LIBS results, we analysed the nail samples with ICP, a standard analytical technique. The elements detected with our LIBS technique are in a good agreement with those identified by ICP-AES. From the health and physiological perspectives, the LIBS system, which is used for spectral analysis in this work, is appropriate for diagnostic purposes such as to find the correlation between vitamin D deficiency and potassium content, especially for hypertensive patients who simultaneously take potassium-based medication and vitamin D supplement. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Determination of 25 trace impurity elements in U3O8 by horizontal ICP-AES after separation with TBP levextrel resin chromatography

    International Nuclear Information System (INIS)

    Guan Jingsu; Shi Youqing; Gao Binghua; Liu Yingmei

    1988-01-01

    A method for the determination of Al, As, Ba, Be, Bi, Ca, Cd, Cu, Co, Cr, Fe, Mg, Mn, Mo, Ni, P, Pb, Ru, Sb, Sn, Sr, Ti, V, W and Zn 25 trace elements in U 3 O 8 is reported. The sample is dissolved in HNO 3 or HNO 3 -HCLO 4 -HF and the uranium is separated by TBP Levextrel resin chromatogyaphy. The impurity elements containing in the aquaous phase are determined by horizontal ICp-AES method. With a sample of 300 mg, the detection limit for all the 25 elements is in the range of 0.01∼5ppm, the recovery is in the range of 82∼ 121%, the determination precision (RSD) is less than ±13%. 18 trace elements in reference material of U 3 O 8 prepared in China are determined, the values obtained well with the values of overall median of accepted laboratory means

  13. Preconcentration and Determination of Copper and Zinc in Natural Water Samples by ICP-AES After Complexation and Sorption on Amberlite XAD-2

    Directory of Open Access Journals (Sweden)

    Ferreira Sérgio Luis Costa

    1998-01-01

    Full Text Available The present paper describes a procedure for separation, preconcentration and sequential determination of trace amounts of copper and zinc in natural water samples, by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES. The proposed method is based on the complexation of copper(II and zinc(II ions by 1-(2-thiazolylazo-2-naphthol (TAN and sorption on to Amberlite XAD-2 resin. Parameters such as: TAN amount, pH effect on the complexation and sorption of TAN complexes, agitation time for complete sorption, concentration of metal ion, mass of Amberlite XAD-2, desorption of metal ions from XAD-2 resin and sample volume were studied. The results demonstrated that the copper(II and zinc(II ions, in the range of 0.10 to 100.00 mug, contained in a solution sample volume of 400 mL, in the pH range of 5.7 to 8.3, on the form of TAN complexes had been quantitatively retained on to XAD-2 resin. The shaking time required for sorption is 1 h using a resin mass of 1.4 g. The solution for determination of copper and zinc by ICP-AES is obtained, after desorption of the ions from the XAD-2 resin, using 5 mL of 2 mol L-1 hydrochloric acid and shaking the system for 5 min. The procedure was applied to the determination of copper and zinc in several natural water samples. The standard addition technique was applied and the obtained recoveries revealed that the proposed procedure has a good accuracy. A high enrichment factor (80 and simplicity are the main advantages in this analytical protocol.

  14. Targeted adhesion for sucralfate to impaired gastric mucosa of SD rats by ICP-AES method%ICP-AES法考察硫糖铝对SD大鼠胃溃疡粘膜的靶向粘附

    Institute of Scientific and Technical Information of China (English)

    李艳; 林凤云; 罗立骏; 曾令高; 朱照静

    2016-01-01

    目的:建立硫糖铝中铝离子(Al3+)在大鼠胃组织残留量的测定方法,考察硫糖铝对胃溃疡粘膜的靶向粘附作用.方法:采用干法灰化消解胃组织样品,电感耦合等离子体-原子发射光谱法(ICP-AES)测定给药后不同时间点大鼠胃组织中Al3+的残留量.ICP-AES检测波长为396.153 nm,检测器为电感耦合阵列检测器,载气为氩气.结果:干法灰化大鼠胃溃疡组织,样品消解完全,可满足ICP-AES的检测要求;在选定的最佳条件下用ICP-AES检测Al3+的检出限为8 ng· mL-1,样品间Al3+残留量相对偏差小于13.4%,回收率在96.0%~99.5%之间;给药0.5~4 h时间段内,溃疡胃组织中的Al3+残留率为正常胃组织的2倍以上;给药6h后,正常胃组织中Al3+残留率显著下降,仅为0.84%,而溃疡胃组织在给药16 h后仍高达29%.结论:ICP-AES测定大鼠胃组织中Al3+的残留量准确可行;硫糖铝对胃溃疡粘膜的粘附性显著高于正常胃粘膜,具有良好的靶向性.

  15. A rapid sample decomposition procedure for bromo-heavies containing ferruginous material: determination of REEs and thorium by ICP-AES

    International Nuclear Information System (INIS)

    Khorge, C.R.; Murugesan, P.; Chakrapani, G.

    2013-01-01

    A rapid method of sample decomposition and dissolution for bromoform heavies is described for the determination of REEs and thorium by inductively coupled plasma- optical emission spectrometry. For application to geochemical exploration to achieve the high sample throughput; a simple and rapid analytical procedure is a prerequisite. In order to speed-up the existing methodology, phosphate fusion was introduced for decomposition of samples. In the proposed method, bromoform-heavies material are fused with 1:1 mixture of sodium dihydrogen orthophosphate and tetra-sodium pyrophosphate and dissolved in distilled water. After disintegration of melt, the solution was subjected to oxalate precipitation followed by R 2 O 3 separation for separating the REEs from major matrix interfering elements. The rare earth elements and thorium in the resultant solution were determined by ICP-OES. The results are compared with the results obtained by well-established existing dissolution procedures involving HF-HCl-HClO 4 acid treatment and NaF/KHF 2 fusion followed by H 2 SO 4 acid fuming. The accuracy of the method was evaluated by doping the phosphate blank with known amount of REEs and comparing the recoveries obtained using the present method. The method is simple, rapid and is suitable for the routine determination of REEs and Th in bromoform-heavies. The RSD of the method was found to be within 1-3% for Th and REEs by ICP-AES. (author)

  16. Chemical yield determination for 59Ni, 63Ni and 56Fe in low and intermediate nuclear wastes by ICP-AES

    International Nuclear Information System (INIS)

    Franco, Milton B.; Santos Neto, Francisco C. dos; Reis Junior, Aluisio S.; Temba, Eliane S.C.; Monteiro, Roberto P.G.

    2011-01-01

    Iron and nickel are constituents of a wide range of metallic materials used in nuclear reactor construction and their corresponding activation products are often encountered in reactor-derived solid low and intermediate-level wastes. The most significant radioisotopes of iron and nickel, in terms of quantity and half life, are 55 Fe (t 1/2 =2.73y), 59 Ni (t 1/2 =7.6x10 4 y) and 63 Ni (t 1/2 =10 2 y) and they are activation products of stable iron and nickel. 59 Ni is an X-ray - emitting and 55 Fe and 63 Ni are β-particle-emitting radionuclides and so they are radionuclides of interest for the performance of assessment studies of waste storage or disposal. For their determination in the radioactive wastes is necessary to know the chemical yield for the radiochemical separation procedures prior analytical measurements. In this work Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) technique was used for this aim. Total nickel and iron in waste samples from nuclear power plants were determined before and after the radiochemical separation at specific wavelengths, 231.604 nm and 259.940 nm respectively. The chemical yields for nickel and iron recovery were around 82 % for iron and 59 % for nickel according the analytical methodology adopted. (author)

  17. [Determination of ru, rh and Pd in 30% trialkyl phosphine oxide (TRPO)-kerosene by inductively coupled plasma-atomic emission spectrum (ICP-AES)].

    Science.gov (United States)

    Wang, Jian-Chen; Zhang, Lin

    2013-07-01

    The determination method of Ru, Rh and Pd in 30% TRPO-kerosene ICP-AES was studied by using aqueous calibration reference solution and choosing ethanol as diluent. The effects of the contents of 30% TRPO-kerosene and aqueous solution and the concentration of HNO3 in 30% TRPO-kerosene on the intensities of Ru, Rh and Pd were described. The optimized condition for preparing samples and calibration solutions was chosen as follows: The contents of 30% TRPO-kerosene and aqueous phase were 10% (V/V) and 5% (V/V) respectively and the concentration of HNO3 30% TRPO-kerosene was 0.20 mol x L(-1). The determination method of Au, Ru and Pd was set up according to the above condition. The detection limit, precision and recovery ratio of Ru, Rh and Pd are well. The method is not only used in determination of Au, Ru and Pd in 30% TRPO-kerosene, but also used in other organic phases.

  18. Feature Fusion of ICP-AES, UV-Vis and FT-MIR for Origin Traceability of Boletus edulis Mushrooms in Combination with Chemometrics.

    Science.gov (United States)

    Qi, Luming; Liu, Honggao; Li, Jieqing; Li, Tao; Wang, Yuanzhong

    2018-01-15

    Origin traceability is an important step to control the nutritional and pharmacological quality of food products. Boletus edulis mushroom is a well-known food resource in the world. Its nutritional and medicinal properties are drastically varied depending on geographical origins. In this study, three sensor systems (inductively coupled plasma atomic emission spectrophotometer (ICP-AES), ultraviolet-visible (UV-Vis) and Fourier transform mid-infrared spectroscopy (FT-MIR)) were applied for the origin traceability of 192 mushroom samples (caps and stipes) in combination with chemometrics. The difference between cap and stipe was clearly illustrated based on a single sensor technique, respectively. Feature variables from three instruments were used for origin traceability. Two supervised classification methods, partial least square discriminant analysis (FLS-DA) and grid search support vector machine (GS-SVM), were applied to develop mathematical models. Two steps (internal cross-validation and external prediction for unknown samples) were used to evaluate the performance of a classification model. The result is satisfactory with high accuracies ranging from 90.625% to 100%. These models also have an excellent generalization ability with the optimal parameters. Based on the combination of three sensory systems, our study provides a multi-sensory and comprehensive origin traceability of B. edulis mushrooms.

  19. Feature Fusion of ICP-AES, UV-Vis and FT-MIR for Origin Traceability of Boletus edulis Mushrooms in Combination with Chemometrics

    Directory of Open Access Journals (Sweden)

    Luming Qi

    2018-01-01

    Full Text Available Origin traceability is an important step to control the nutritional and pharmacological quality of food products. Boletus edulis mushroom is a well-known food resource in the world. Its nutritional and medicinal properties are drastically varied depending on geographical origins. In this study, three sensor systems (inductively coupled plasma atomic emission spectrophotometer (ICP-AES, ultraviolet-visible (UV-Vis and Fourier transform mid-infrared spectroscopy (FT-MIR were applied for the origin traceability of 184 mushroom samples (caps and stipes in combination with chemometrics. The difference between cap and stipe was clearly illustrated based on a single sensor technique, respectively. Feature variables from three instruments were used for origin traceability. Two supervised classification methods, partial least square discriminant analysis (FLS-DA and grid search support vector machine (GS-SVM, were applied to develop mathematical models. Two steps (internal cross-validation and external prediction for unknown samples were used to evaluate the performance of a classification model. The result is satisfactory with high accuracies ranging from 90.625% to 100%. These models also have an excellent generalization ability with the optimal parameters. Based on the combination of three sensory systems, our study provides a multi-sensory and comprehensive origin traceability of B. edulis mushrooms.

  20. Comparison of digestion procedures used for the determination of boron in biological tissues by ICP-AES [inductively-coupled, plasma-atomic emission spectroscopy

    International Nuclear Information System (INIS)

    Bauer, W.F.; Miller, D.L.; Steele, S.M.

    1988-01-01

    A study was designed to identify the most accurate and reliable procedures for the digestion of biological tissues prior to the determination of boron by inductively-coupled, plasma-atomic emission spectroscopy (ICP-AES). The four procedures used in this study were an acid bomb digestion and digestions performed in test tubes using perchloric acid and hydrogen peroxide, nitric acid and hydrogen peroxide, and nitric acid alone. Digestions using nitric acid and hydrogen peroxide and nitric acid alone were performed in a manner analogous to the perchloric acid/hydrogen peroxide procedure. The tissues used in the study were from dogs that had been administered a boron compound (Na 2 B 12 H 11 SH) and included two brain tissues, a liver and a tongue. These tissues were selected in order to eliminate results that may be due to surface spiking only. None of the test tube procedures were successful in completely dissolving the samples, as was evidenced by residual color and a coagulated precipitate. The amount of precipitate was much larger for the brain tissues in all cases. The acid bomb digestion and the perchloric acid/hydrogen peroxide procedures gave comparable boron concentrations for all of the tissues in this study. 2 refs., 1 tab

  1. [Analysis of mineral elements of sunflower (Helianthus annuus L.) grown on saline land in Hetao Irrigation District by ICP-AES].

    Science.gov (United States)

    Tong, Wen-Jie; Chen, Fu; Wen, Xin-Ya

    2014-01-01

    The absorption and accumulation of ten mineral elements in four kinds of organs (root, steam, leaf and flower disc) in Helianthus annuus L. plants cultured in Hetao Irrigation District under different level of salinity stress were determined by ICP-AES with wet digestion (HNO3 + HClO4). The results showed that: (1) The contents of Fe, Mn, Zn, Ca, and Na were highest in roots, so was K in stems, B and Mg in leaves and P in flower discs, while no significant difference was detected in the content of Cu among these organs; (2) The cumulants of Ca, Mg, P, Cu, B and Zn were highest in flower discs, so were Na, Fe and Mn in roots and K in stems; (3) In sunflower plants, the proportion of mineral element cumulant for K : Ca : Mg : P : Na was 16.71 : 5.23 : 3.86 : 1.23 : 1.00, and for Zn : Fe : B : Mn: Cu was 56.28 : 27.75 : 1.93 : 1.17 : 1.00, respectively; (4) The effect of salinity stress on absorption of mineral elements differed according to the kind of organ and element, root was the most sensitive to soil salt content, followed by stem and leaf, and the effect on flower disc seemed complex.

  2. Flotation-separation and ICP-AES determination of ultra trace amounts of copper, cadmium, nickel and cobalt using 2-aminocyclopentene-1-dithiocarboxylic acid.

    Science.gov (United States)

    Shamsipur, Mojtaba; Hashemi, Omid Reza; Safavi, Afsaneh

    2005-09-01

    A rapid flotation method for separation and enrichment of ultra trace amounts of copper(II), cadmium(II), nickel(II) and cobalt(II) ions from water samples is established. At pH 6.5 and with sodium dodecylsulfate used as a foaming reagent, Cu2+, Cd2+, Ni2+ and Co2+ were separated simultaneously with 2-aminocyclopentene-1-dithiocarboxylic acid (ACDA) added to 1 l of aqueous solution. The proposed procedure of preconcentration is applied prior to the determination of these four analytes using inductivity coupled plasma-atomic emission spectrometry (ICP-AES). The effects of pH, concentration of ACDA, applicability of different surfactants and foreign ions on the separation efficiency were investigated. The preconcentration factor of the method is 1000 and the detection limits of copper(II), cadmium(II), nickel(II) and cobalt(II) ions are 0.078, 0.075, 0.072 and 0.080 ng ml(-1), respectively.

  3. Determination of the mineral compositions of some selected oil-bearing seeds and kernels using Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES

    Directory of Open Access Journals (Sweden)

    Musa Özcan, M.

    2006-06-01

    Full Text Available The aim of this paper was to establish the mineral contents of oil-bearing seeds and kernels such as peanut, turpentine, walnut, hazelnut, sesame, corn, poppy, almond, sunflower etc., using Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES. Significant differences in mineral composition were observed among crops. All seeds and kernels contained high amounts of Al, Ca, Fe, K, Mg, Na, P and Zn. B, Cr, Cu, Li, Ni, Sr, Ti while V contents of the crops were found to be very low. The levels of K and P of all crops in this study were found to be higher than those of other seeds and kernels. The results obtained from analyses of the crops showed that the mean levels of potassiumcontent ranged from 1701.08 mg/kg (corn to 20895.8 mg/kg (soybean, the average content of phosphorus ranged from 3076.9 mg/kg (turpentine to 12006,5 mg/kg to 2617.4 mg/kg (cotton seed, and Ca from 68.4 mg/kg (corn to 13195.7 mg/kg (poppy seed. The results show that these values may  be useful for the evaluation of dietary information. Particularly the obtained results provide evidence that soybean, pinestone and poppy seed are a good source of K, P and Ca, respectively. Whereas pinestone is a good source of zinc.La finalidad del trabajo es establecer el contenido en elementos minerales de semillas oleaginosas tales como cacahuetes, trementina, avellana, sesamo, maiz, almendras, girasol, utilizando ICP-AES. Se han observado diferencias significativas en la composición de minerales entre cosechas. Todas las semillas contienen cantidades elevadas de Al, Ca, Fe, K, Mg, Na, P y Zn. Los contenidos de B, Cr, Cu, Li, Ni, Sr, Ti y V, sin embargo, fueron bajos. Los contenidos de K y P en todas las semillas estudiadas fueron superiores a las de otras semillas. El contenido medio de K osciló entre 1.701,1 mg/kg (maiz a 20.895,8 mg/kg (soja, el P entre 3.076.9 mg/kg (trementina a 12.006.5 mg/kg o 2.617,4 mg/kg (semilla de algodón, y Ca de 68,4 mg/kg (maiz a 13.195,7 mg

  4. [Mineral elements analysis of Momordica charantiap seeds by ICP-AES and fatty acid profile identification of seed oil by GC-MS].

    Science.gov (United States)

    Liu, Xiao-ru; Deng, Ze-yuan; Fan, Ya-wei; Li, Jing; Liu, Zhi-han

    2010-08-01

    In the present study, a special kind of Momordica charantia seeds produced in Hai Nan was selected and analyzed. Firstly, inductively coupled plasma-atomic emission spectrophotometry (ICP-AES) was used to determine the mineral elements. It was clear that the contents of K, Mg and P are the highest in the seeds; Cr and Zn takes up to 5.65% and 45.45% high, especially, which are rare in plant foods. These minerals, especially Cr and Zn might have a complex effect on those proteins or polysaccharides and form a stronger anticipation of hyperlipidemia, hyperglycemia and cholesterol. Secondly, seed oil was extracted by supercritical CO2 extraction with a yield ratio of 36.89, and the fatty acids were treated by methylation in alkaline process and purified by thin-layer chromatography, then analyzed by gas chromatography-mass spectrometer (GC-MS) identification. The saturated fatty acids (SFA) take up 36.712, and mainly are stearic acid; monounsaturated fatty acid (MUFA) is only 3.33% which is dominantly linoleic acid (LA); Polyunsaturated fatty acid (PUFA) accounted for 59.96%, and the alpha-eleostearic acid takes up 54.26% as the main fatty acids in all. The plentiful alpha-eleostearic acid leads to strong effects of inhibiting tumor cell proliferation, lowering blood fat, anti-cancer, anti-inflammatory and preventing cardiovascular diseases, and so on. Knowing clearly the mineral elements distribution and identifying the composition of fatty acid, especially the main fatty acids in the oil, are both of great guiding importance to further exploit the clinical and edible value in Momordica charantiap seeds.

  5. [Determination of total mass and morphology analysis of heavy metal in soil with potassium biphthalate-sodium hydroxide by ICP-AES].

    Science.gov (United States)

    Qu, Jiao; Yuan, Xing; Cong, Qiao; Wang, Shuang

    2008-11-01

    Blank soil was used as quality controlling samples, soil sample dealt by potassium biphthalate-sodium hydroxide buffer solution was used as check sample, mixed acid HNO3-HF-HClO4 was chosen to nitrify soil samples, and plasma emission spectrometer (ICP-AES) was used as detecting method. The authors determined the total metal mass of Mo, Pb, As, Hg, Cr, Cd, Zn, Cu and Ni in the extracted and dealt soil samples, and determined the mass of Mo, Pb, As, Hg, Cr, Cd, Zn, Cu and Ni in the three chemical morphologies, including acid extractable morphology, oxide associated morphology, and organics associated modality. The experimental results indicated that the different pH of potassium biphthalate-sodium hydroxide buffer solution had obvious influence on the total mass of heavy metal and morphology transformation. Except for metal element Pb and Zn, the addition of different pH potassium dihydrogen phosphate-sodium hydroxide buffer solution could accelerate the soil samples nitrification and the total mass determination of heavy metal in the soil samples. The potassium biphthalate-sodium hydroxide buffer solution could facilitate the acid extractable morphology of Cr, Cu, Hg and Pb, oxidation associated morphology of As, Hg, Pb and Zn and the organic associated morphology transforming of As and Hg. At pH 5.8, the maximum acid extractable morphology contents of Cu and Hg were 2.180 and 0.632 mg x kg(-1), respectively; at pH 6.2, the maximal oxidation associated morphology content of Pb could achieve 27.792 mg x kg(-1); at pH 6.0, the maximum organic associated morphology content of heavy metal Hg was 4.715 mg x kg(-1).

  6. Multielement Determination of Major-to Ultratrace Elements in a Cabbage, Spinach, and the Japanese Radish by ICP-AES After Acid Digestion

    OpenAIRE

    畑山, 友紀; 奴田原, 杏奈; 藤井, 和美; 西島, 基弘; ハタヤマ, ユキ; ヌタハラ, アンナ; フジイ, カズミ; ニシジマ, モトヒロ; Yuki, Hatayama; anna, Nutahara; Kazumi, Fujii; Motohiro, Nishijima

    2011-01-01

    A multi-element determination in a cabbage, spinach, and the Japanese radish was carried out by inductively coupled plasma atomic emission spectrometry (ICP). We investigated whether there was a difference in content according to the part of the vegetables. The dried vegetables (0.5g) were digested with nitric acid and with hydrogen peroxide acid in a resolution device As a result, about 9 elements were successfully determined. The values of the coefficient of variance for part interval by ea...

  7. Determination of trace metals in TSP and PM2.5 materials collected in the Metropolitan Area of Monterrey, Mexico: A characterization study by XPS, ICP-AES and SEM-EDS

    Science.gov (United States)

    González, Lucy T.; Longoria Rodríguez, F. E.; Sánchez-Domínguez, M.; Cavazos, Aleyda; Leyva-Porras, C.; Silva-Vidaurri, L. G.; Askar, Karim Acuña; Kharissov, B. I.; Villarreal Chiu, J. F.; Alfaro Barbosa, J. M.

    2017-11-01

    The concentration levels of trace metals of toxicological importance were evaluated in the total suspended particles (TSP) and particulate matter smaller than 2.5 μm (PM2.5) collected in the Metropolitan Area of Monterrey (MAM) in Mexico. Samples were characterized by inductively coupled plasma atomic emission spectroscopy (ICP-AES), X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy with an energy-dispersive spectroscopy system (SEM-EDS). In addition, the data were statistically treated by the methodology of Pearson Correlation (PC) and Principal Components Analysis (PCA) to identify the possible emitting sources. Surface analysis of the particulate matter (PM) by XPS revealed that the most abundant elements were Ca, Al, Na, Zn, Cu and Mg. The deconvolution of the Ca2p, Zn2p and Cu2p signals showed that the main contributors were CaCO3, ZnO and Cu/Cu2O, respectively. The bulk analysis of the PM by ICP-AES showed Fe, Cu and Zn as the most abundant elements. Fe-rich particles presented two different morphologies: the prismatic particles were associated with a natural origin, while the spherical particles with anthropogenic sources. The Zn and Cu were predominantly observed in the sampling stations with high vehicular traffic, and the emitting sources were associated with the burning of fuels from automobiles and the wear of the tires and brakes. The highest concentration of Pb was detected in the sampling station located near the industrial zones, and its cause was associated with the ceramic and glass industries, the burning of fuel oil in power plants and the production of lead-based batteries for automobiles.

  8. Following the evolution of morphology, composition and crystallography of alumina based catalysts after laser ablation: Implications for analysis by LA-ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Alloncle, G. [Universite de Lyon, Lyon1, Laboratoire des Sciences Analytiques, CNRS UMR 5180, bat CPE, 43, boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Direction Physique et Analyses, Institut Francais du Petrole (IFP)-Lyon, BP3, F-69360 Solaize (France); Gilon, N., E-mail: gilon@univ-lyon1.fr [Universite de Lyon, Lyon1, Laboratoire des Sciences Analytiques, CNRS UMR 5180, bat CPE, 43, boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Legens, C.; Lienemann, C.-P.; Rebours, B.; Sorbier, L. [Direction Physique et Analyses, Institut Francais du Petrole (IFP)-Lyon, BP3, F-69360 Solaize (France); Morin, S.; Revel, R. [Direction Catalyse et Separation, Institut Francais du Petrole (IFP)-Lyon, BP3, F-69360 Solaize (France)

    2009-08-30

    Fundamental understanding of aerosol formation during laser ablation is important for the development of LA-ICP analysis of complex samples. Using a Lina Spark Atomizer{sup TM}, the application of this technique to the field of heterogeneous catalysis gave an accuracy of 5-15% while extreme values of +100% could be obtained in some cases. To improve understanding of laser ablation processes, particles generated during ablation of alumina based catalysts were collected and analysed using different microscopy and surface analysis techniques. Morphological study by scanning electron microscopy showed that most of the particles leaving the ablation cell were nanoparticle aggregates generated from vapor condensation. An XRD study of these aerosols revealed that the condensation converge on the formation of a spinel structure with large coherence domains. Elemental composition of the aerosol was also followed and exhibited differences between a catalyst containing large Mo concentration or low Pt concentration.

  9. Characterization of Polish rape and honeydew honey according to their mineral contents using ICP-MS and F-AAS/AES

    International Nuclear Information System (INIS)

    Madejczyk, Maria; Baralkiewicz, Danuta

    2008-01-01

    In this work twelve elements (Al, B, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni and Zn) were determined in 30 honey samples from various locations within Poland and in two different types of honey- rape and honeydew. Trace elements (Al, B, Cr, Mn and Ni) were determined by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), however, major elements (Ca, K, Mg, Na) and Cu, Fe, Zn were determined by Flame Atomic Absorption Spectrometry (F-AAS). Cluster analysis of honey data revealed that the origin of honey samples correlated with their chemical composition. It was shown that rape honey includes lower amounts of manganese than honeydew honeys. Also honeydew honey includes much higher concentrations of Al, Cu, K, Fe and Ni in comparison with rape honey. Moreover honeydew honey was found to have a higher mineral content, which reflects sources from which the honey is composed. Trace element analysis showed that the differences in the values found in honey samples could be used as evidence of the quality of honey samples

  10. Study of Long-Lived Radionuclides in Environmental Samples by ICP-MS; Estudio de Radionucleidos de Vida Larga en Muestras Medioambientales por ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Conde, E.; Navarro, N.; Fernández, M.

    2015-07-01

    Thorium is considered as one of the highly radiotoxic elements, because following its decay a number of other α, β and/or γ emitting daughters are produced. Uranium mining and processing, as well as remediation of impacted soils, are one of the principal anthropogenic sources of thorium release to the air, soil and water. Measurement of Th isotopes requires the use of analytical techniques capable of reliably measure the content of Th isotopes at trace levels. 230Th determination has generally been performed by α-spectrometry. However, this method needs sample preparation of 3-4 days and counting times from days to up to two weeks. A way to face this difficulty is the use of inductively coupled plasma mass spectrometry (ICP-MS). This technique is adequate for the determination of 232Th and 238U, long-lived radionuclides, and it can be applied, successfully, in the determination of 230Th, particularly if it is associated with a pre-concentration stage. This work presents the development of a rapid and simple analytical procedure based on mass spectrometry for the determination of 230Th and the results obtained in the analysis of environmental filters.

  11. Direct determination of uranium in human urine by Icp-SFMS; Determinacion directa de uranio en orina humana por ICP-SFMS

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, H. [ININ, Departamento de Quimica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Yllera de Ll, A., E-mail: hector.hernandez520@gmail.com [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Departamento de Medio Ambiente, Av. Complutense 22, 28040 Madrid (Spain)

    2013-10-15

    The success of the measurement and the evaluation of the internal exposure are highly dependent of the effective capacities for the radiation measurement in biological samples (mainly urine and the feces). Usually, during the samples bioassay of human urine, a pre-concentration and purification of the radionuclides is carried out previously to the quantitative analysis. These stages, as the analysis time are the main source of uncertainty in the measurement process. In the uranium case, this is not necessary when are used mass spectrometry techniques, in particular, Mass Spectrometry of Magnetic Sector with Inductively Coupled Plasma (Icp-SFMS). This work presents the results obtained for the uranium analysis in samples of human urine during the participation in the inter-comparison exercises of the Association pour la Promotion de Controle de Qualite des Analyses de Biologie Medicale en Radiotoxicologie (PROCORAD) in the period 2010 and 2011. The analyses were realized directly in the diluted urine samples (dilution factor 1:20) in 5% of HNO{sub 3}. The obtained results, were normalized to the total urine sample (V = 0.5 L), these values coincide with the waited reference values of uranium in the urine sample. Additionally, were calculated the detection limits of {sup 235}U= 0.049 x 10{sup -3} μg L{sup -1} and {sup 238}U= 7.37 x 10{sup -3} μg L{sup -1}. (author)

  12. Development of a methodology for the determination of radionuclides by Icp-SFMS; Desarrollo de una metodologia para la determinacion de radionuclidos en aerosoles por ICP-SFMS

    Energy Technology Data Exchange (ETDEWEB)

    Mendez G, C. G.; Romero G, E. T.; Hernandez M, H. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Solis R, C.; Chavez L, E. R., E-mail: griselmendez@fisica.unam.mx [UNAM, Instituto de Fisica, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico)

    2016-09-15

    A methodology was established for the determination of {sup 75}As, {sup 202}Hg, {sup 208}Pb, {sup 60}Ni, {sup 232}Th, {sup 234}U, {sup 235}U, {sup 238}U, by magnetic field inductive coupling mass spectrometry (Icp-SFMS) of various samples at the National Laboratory of Nuclear Forensic Research of the Instituto Nacional de Investigaciones Nucleares (ININ) in order to determine radionuclides in aerosol samples. The concentrations calculation of {sup 75}As, {sup 202}Hg, {sup 208}Pb and {sup 60}Ni allowed to validate the reliability of the proposed methodology when comparing the concentrations obtained with the application of the same and the concentrations of the same elements reported for the Certified Reference Material (CRM) of particulate atmospheric material of an urban area (Nist 1648-a), the comparison showed that the proposed methodology is feasible for the determination of not only radionuclides, but also for these trace elements. Detection and quantification limits of the order of microns of ng L{sup -1} were reached, corroborating with this the acceptance of the proposed methodology. Concentrations of the radionuclides of interest for CRM could be calculated. The concentrations of the radionuclides found in white samples and of the reagents used in the processing of the aerosol filters indicated that the calculations found belong to or correspond to the calculations that are reflected in the background measurement. Concentrations of {sup 232}Th, {sup 234}U, {sup 235}U and {sup 238}U in aerosols of the Cuernavaca City, Morelos (Mexico) showed higher values than those established by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), however the concentration of the radioisotopes per unit volume are within the typical values reported for the northern hemisphere; the value of isotopic ratios greater than unity point to the influence of anthropogenic activities or environmental factors such as the direction of the wind or the

  13. AE 941.

    Science.gov (United States)

    2004-01-01

    AE 941 [Arthrovas, Neoretna, Psovascar] is shark cartilage extract that inhibits angiogenesis. AE 941 acts by blocking the two main pathways that contribute to the process of angiogenesis, matrix metalloproteases and the vascular endothelial growth factor signalling pathway. When initial development of AE 941 was being conducted, AEterna assigned the various indications different trademarks. Neovastat was used for oncology, Psovascar was used for dermatology, Neoretna was used for ophthalmology and Arthrovas was used for rheumatology. However, it is unclear if these trademarks will be used in the future and AEterna appears to only be using the Neovastat trademark in its current publications regardless of the indication. AEterna Laboratories signed commercialisation agreements with Grupo Ferrer Internacional SA of Spain and Medac GmbH of Germany in February 2001. Under the terms of the agreement, AEterna has granted exclusive commercialisation and distribution rights to AE 941 in oncology to Grupo Ferrer Internacional for the Southern European countries of France, Belgium, Spain, Greece, Portugal and Italy. It also has rights in Central and South America. Medac GmbH will have marketing rights in Germany, the UK, Scandinavia, Switzerland, Austria, Ireland, the Netherlands and Eastern Europe. In October 2002, AEterna Laboratories announced that it had signed an agreement with Australian healthcare products and services company Mayne Group for marketing AE 941 (as Neovastat) in Australia, New Zealand, Canada and Mexico. In March 2003, AEterna Laboratories announced it has signed an agreement with Korean based LG Life Sciences Ltd for marketing AE 941 (as Neovastat) in South Korea. The agreement provides AEterna with upfront and milestone payments, as well as a return on manufacturing and sales of AE 941. AEterna Laboratories had granted Alcon Laboratories an exclusive worldwide licence for AE 941 for ophthalmic products. However, this licence has been terminated. In

  14. Fósforo extraído pela solução de Mehlich-1 determinado por colorimetria e ICP em solos do Sul do Brasil Phosphorus extracted with Mehlich-1 determined by colorimetric and ICP methods in South Brazilian soils

    Directory of Open Access Journals (Sweden)

    Leandro Bortolon

    2010-02-01

    Full Text Available A adoção do ICP para análise de fósforo tem apresentado controvérsias, pois o valor determinado por essa técnica, muitas vezes, não é comparável com o obtido por colorimetria. Nos EUA, alguns laboratórios apresentam restrições à adoção dessa técnica, pelas seguintes razões: as recomendações de adubação em uso foram desenvolvidas empregando-se o método colorimétrico para a determinação do P; e as diferenças significativas têm sido obtidas entre os teores determinados por colorimetria e por ICP, pois, devido à alta temperatura do plasma, o ICP mede outras formas de P além do ortofosfato, atribuída ao P orgânico na solução. Este estudo teve por objetivo comparar os teores de P extraído do solo pela solução de Mehlich-1, determinado por colorimetria (COL e por ICP, em 595 amostras de solos do Estado do Rio Grande do Sul, com amplas variações nas características físicas, químicas e mineralógicas. Os teores de P extraído, determinado por ICP e por COL, não diferiram estatisticamente (r = 0,94; p The adoption of ICP technique to determine P in soil testing has been questioned, due the values determined with this technique is not comparable that those determined with colorimetric method. In the USA, some laboratories are restricted to adopt the ICP technique due the follow reasons: the nutrient recommendations to plants were developed for colorimetric method for P determination; significantly differences have been obtained between P determined with colorimetric and ICP techniques, because the high plasma temperature can measure other P forms besides orthophosphate, attributed to organic P in solution. This study compared the P amounts extracted by Mehlich-1 solution and determined by COL and ICP techniques, in 595 soil samples from the state of Rio Grande do Sul (Brazil with s wide range of soil physic, chemistry and mineralogic properties. The P amounts determined by ICP and COL did not differ statistically

  15. Determination of boron by ICP-AES in normal and malignant cells incubated 'in vitro' with fructose {sup 10}BPA; Determinacion de boro por ICP-AES para el estudio de captacion por celulas malignas y normales incubadas 'in vitro' con fructosa-BPA

    Energy Technology Data Exchange (ETDEWEB)

    Garavaglia, Ricardo N; Farias, Silvia S; Rodriguez, Ruben E; Servant, Roberto E; Liberman, Sara; Pisarev, Mario A; Batistoni, Daniel A [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Quimica

    1999-07-01

    This paper describes the development and optimization of methodology for total boron concentration in cell cultures coming from fixation and accumulation of this element by normal and malignant cells. On account of sample mass and low volume resulting from dilution, generally about 1 mL, a procedure for automatic injection of micro volumes was designed, developed and optimized. Iron interference was carefully studied. Linear calibration curves were obtained for 50 to 2500 ng B/mL range. Determination limits were 10 and 20 ng B/mL for B 249.772 nm and 249.677 nm, respectively. Repeatability, expressed as relative standard deviation was better than 5% for a 100 ng B/mL. Recovery of analyte added to real samples ranged between 95 and 103%. The method was applied to studies on F-98 cells (rat glioma) and normal glia in BNCT project frame. (author)

  16. Methodology for determination of trace elements in mineral phases of iron banded formation by LA-ICP-MS; Metodologia de determinacao de elementos-traco em fases minerais de formacoes ferriferas bandadas por LA-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, Denise V.M. de; Nalini Junior, Herminio A.; Sampaio, Geraldo M.S.; Abreu, Adriana T. de; Lana, Cristiano de C., E-mail: deniseversiane2@yahoo.com.br, E-mail: nalini@degeo.ufop.br, E-mail: geraldomssampaio@gmail.com, E-mail: adrianatropia@gmail.com, E-mail: cristianodeclana@gmail.com [Universidade Federal de Ouro Preto (DEGEO/UFOP), Ouro Preto, MG (Brazil). Departamento de Geologia

    2015-07-01

    The study of the chemical composition of mineral phases of iron formation (FF), especially of trace elements, is an important tool in the understanding of the genesis of these rocks and the contribution of the phases in the composition of whole rock. Low mass fraction of such elements in the mineral phases present in this rock type requires a suitable analytical procedure. The laser ablation technique coupled with ICP-MS (LA-ICP-MS) has been widely used for determination of trace elements in geological samples. Thus, the aim of this study is to develop calibration curves for determination of trace elements (Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) in mineral phases of banded iron formations by LA-ICP-MS. Several certified reference materials (CRM) were used for calibrate the equipment. The analytical conditions were checked by CRM NIST SRM 614. The results were satisfactory, since the curves showed good linearity coefficients, good accuracy and precision of results. (author)

  17. Determination of metal traces in lubricating oils by Aas and Icp-SFMS after microwave digestion; Determinacion de trazas metalicas en aceites lubricantes mediante EAA e ICP-SFMS despues de la digestion por microondas

    Energy Technology Data Exchange (ETDEWEB)

    Perez B, M. A.; Acosta L, C. E.; Hernandez M, H.; Romero G, E. T.; Lara A, N.; Kuri C, A., E-mail: manuel.perez@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    The analysis of lubricating oils allows to monitor the operating conditions of the machines and equipment, their pollution levels, degradation and finally their wear and useful life, as well as to establish a preventive lubrication program as a technical diagnostic maintenance tool. The useful life of oil is the period of functional time has in the machine until the antioxidants are consumed, producing large changes in the physical (density and viscosity) and chemical properties of the base oil, resulting in a wear of the components that make up the machine. The present work includes a theoretical as well as analytical basis for determining the content of metallic elements (Ag, Al, Cu, Fe, Mg, Sn and Zn) at trace level in used lubricating oils. A simple and rapid method of analysis is proposed, consisting mainly of the pretreatment of the sample by acidic digestion with a microwave oven. Subsequently an open digestion in a heating plate is carried out to dryness and recovered with concentrated HNO{sub 3}. For the quantitative analysis two analytical techniques were used: flame atomic absorption spectroscopy (Aas) and magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS). In both cases, the proposed method offers a good linearity and sensitivity for each of the trace elements under study. The accuracy of the method expressed as relative standard deviation ranges from 1.4 to 2.3%. In relation to the accuracy measurement, an oil was also analyzed as a certified reference material (Conostan 500 mg/L), with the concentration of certified Mg, obtaining satisfactory results. (Author)

  18. Avaliação da salinização de açudes no semi-árido brasileiro por ICP-AES Evaluation of the salt accumulation process in water resources in the Brazilian semi - arid area by ICP-- AES

    Directory of Open Access Journals (Sweden)

    José Soares dos Santos

    2000-08-01

    Full Text Available The salt accumulation process in some reservoirs of regular and irregular use (from 10 to 50 years of constrution, located in the Southeast of Bahia State was evaluated. Inductively coupled plasma atomic emission spectrometry was used to evaluate the concentrations of Na, K, Ca and Mg in water samples from inside and upstream of the reservoirs. The results showed that for reservoirs of irregular use, the salt accumulation, indicated by the tracer Na, increases with the age of the reservoirs, however for the reservoirs of regular use the hydraulic retention time is the main parameter.

  19. Uranium spectra in the ICP

    Energy Technology Data Exchange (ETDEWEB)

    Ghazi, A.A.; Qamar, S.; Atta, M.A. (Khan (A.Q.) Research Labs., Rawalpindi (Pakistan))

    1994-05-01

    Uranium spectra have been studied by inductively coupled plasma atomic emission spectroscopy (ICP-AES). In total, 8361 uranium lines were observed in the wavelength range of 235-500 nm. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hard copy text is accompanied by a disk with data files and test files for an IBM-compatible computer. The main article discusses the scientific aspects of the subject and explains the purpose of the data files. (Author).

  20. Uranium spectra in the ICP

    International Nuclear Information System (INIS)

    Ghazi, A.A.; Qamar, S.; Atta, M.A.

    1994-01-01

    Uranium spectra have been studied by inductively coupled plasma atomic emission spectroscopy (ICP-AES). In total, 8361 uranium lines were observed in the wavelength range of 235-500 nm. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hard copy text is accompanied by a disk with data files and test files for an IBM-compatible computer. The main article discusses the scientific aspects of the subject and explains the purpose of the data files. (Author)

  1. DETERMINAÇÃO SIMULTÂNEA DE METAIS E ENXOFRE POR ICP-OES EM RESÍDUOS DE DESTILAÇÃO DE PETRÓLEO

    Directory of Open Access Journals (Sweden)

    Gabriel T. Druzian

    Full Text Available A method for digestion of crude oil distillation residues (atmospheric residue, AR and vacuum residue, VR using microwave-induced combustion (MIC was developed for simultaneous determination of metals (Ba, Co, Fe, Mg, Mn, Ni and V and sulfur by inductively coupled plasma optical emission spectrometry (ICP-OES. Samples were wrapped in polyethylene films and combusted using 20 bar of oxygen. Nitric acid solutions were evaluated using 5 min of reflux after combustion. Accuracy was evaluated using certified reference material and comparison with the results obtained by microwave-assisted wet digestion (MAWD. No statistical difference was observed between the certified values and those obtained using MIC as well as between the values obtained using MAWD or MIC. In spite of both methods have been apparently suitable for crude oil digestion, MIC was preferable in view of the possibility of using 3 mol L-1 HNO3 as absorbing solution. Furthermore, it is important to notice that using MIC, C content in digests was lower than 10 mg L-1, preventing interferences in ICP-OES. In addition, the simultaneous digestion of eight samples was possible in less than 30 min and without using concentrated acids and/or longer heating times, making the proposed method well-suited for routine analysis.

  2. AES Modular Power Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — The AES Modular Power Systems (AMPS) project will demonstrate and infuse modular power electronics, batteries, fuel cells, and autonomous control for exploration...

  3. A More Compact AES

    OpenAIRE

    Canright, David; Osvik, Dag Arne

    2009-01-01

    We explore ways to reduce the number of bit operations required to implement AES. One way involves optimizing the composite field approach for entire rounds of AES. Another way is integrating the Galois multiplications of MixColumns with the linear transformations of the S-box. Combined with careful optimizations, these reduce the number of bit operations to encrypt one block by 9.0%, compared to earlier work that used the composite field only in the S-box. For decryption, ...

  4. A More Compact AES

    Science.gov (United States)

    Canright, David; Osvik, Dag Arne

    We explore ways to reduce the number of bit operations required to implement AES. One way involves optimizing the composite field approach for entire rounds of AES. Another way is integrating the Galois multiplications of MixColumns with the linear transformations of the S-box. Combined with careful optimizations, these reduce the number of bit operations to encrypt one block by 9.0%, compared to earlier work that used the composite field only in the S-box. For decryption, the improvement is 13.5%. This work may be useful both as a starting point for a bit-sliced software implementation, where reducing operations increases speed, and also for hardware with limited resources.

  5. Secure Multiparty AES

    Science.gov (United States)

    Damgård, Ivan; Keller, Marcel

    We propose several variants of a secure multiparty computation protocol for AES encryption. The best variant requires 2200 + {{400}over{255}} expected elementary operations in expected 70 + {{20}over{255}} rounds to encrypt one 128-bit block with a 128-bit key. We implemented the variants using VIFF, a software framework for implementing secure multiparty computation (MPC). Tests with three players (passive security against at most one corrupted player) in a local network showed that one block can be encrypted in 2 seconds. We also argue that this result could be improved by an optimized implementation.

  6. ICP (ITER Collaborative Platform)

    Energy Technology Data Exchange (ETDEWEB)

    Capuano, C.; Carayon, F.; Patel, V. [ITER, 13 - St. Paul-Lez Durance (France)

    2009-07-01

    The ITER organization has the necessity to manage a massive amount of data and processes. Each team requires different process and databases often interconnected with those of others teams. ICP is the current central ITER repository of structured and unstructured data. All data in ICP is served and managed via a web interface that provides global accessibility with a common user friendly interface. This paper will explain the model used by ICP and how it serves the ITER project by providing a robust and agile platform. ICP is developed in ASP.NET using MSSQL Server for data storage. It currently houses 15 data driven applications, 150 different types of record, 500 k objects and 2.5 M references. During European working hours the system averages 150 concurrent users and 20 requests per second. ICP connects to external database applications to provide a single entry point to ITER data and a safe shared storage place to maintain this data long-term. The Core model provides an easy to extend framework to meet the future needs of the Organization. ICP follows a multi-tier architecture, providing logical separation of process. The standard three-tier architecture is expanded, with the data layer separated into data storage, data structure, and data access components. The business or applications logic layer is broken up into a common business functionality layer, a type specific logic layer, and a detached work-flow layer. Finally the presentation tier comprises a presentation adapter layer and an interface layer. Each layer is built up from small blocks which can be combined to create a wide range of more complex functionality. Each new object type developed gains access to a wealth of existing code functionality, while also free to adapt and extend this. The hardware structure is designed to provide complete redundancy, high availability and to handle high load. This document is composed of an abstract followed by the presentation transparencies. (authors)

  7. ICP-MS Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Carman, April J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eiden, Gregory C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-11-01

    This is a short document that explains the materials that will be transmitted to LLNL and DNN HQ regarding the ICP-MS Workshop held at PNNL June 17-19th. The goal of the information is to pass on to LLNL information regarding the planning and preparations for the Workshop at PNNL in preparation of the SIMS workshop at LLNL.

  8. Determination of trace elements in seawater by air-flow injection/ICP-MS with chelating resin preconcentration

    International Nuclear Information System (INIS)

    Lee, Kyue-Hyung; Ohshima, Mitsuko; Motomizu, Shoji

    2002-01-01

    Multielement determination of major to trace metals in a deep seawater malt was accomplished by inductively coupled plasma-mass spectrometry (ICP-MS) together with inductively coupled plasma-atomic emission spectrometry (ICP-AES). Major elements, such as Na, K, Mg, and Ca, were measured by ICP-AES and normal continuos nebulization ICP-MS after sample dilution by 10 3 -10 6 fold. Fifteen trace elements in the concentrated metal solutions pretreated with cation-exchange resin or chelating resin could be simultaneously determined by air-flow injection/ICP-mass spectrometry (AFI/ICP-MS). Since the injection volume for AFI/ICP-MS was 25 μl, final samples volumes less than 500 μl were enough for several replicate measurements. Three different preconcentration methods assisted with AFI/ICP-MS were examined and could be successfully applied to a deep seawater malt. The analytical results of rate earth elements (REEs) and Co, Ni, Cu, Zn, Cd, and Pb obtained by AFI/ICP-MS coupled with disk filtration method using iminodiacetate (IDA)-type chelating resin were favorably agreed with the data obtained by AFI/ICP-MS coupled with column preconcentration method using chitosan-based chelating resin. (author)

  9. References: AePW publications

    Data.gov (United States)

    National Aeronautics and Space Administration — This page is the repository for the publications resulting from the AePW. This includes the special sessions at conferences: AIAA ASM 2012, Grapevine TX; AIAA SDM...

  10. Establishment of methodology for determination of {sup 93}Zr in radioactive wastes by Liquid Scintillation Counting (LSC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS); Estabelecimento de metodologia para determinacao de {sup 93}Zr em rejeitos radioativos por Espectrometria de Cintilacao Liquida (LSC) e Espectrometria de Massa com Plasma Indutivamente Acoplado (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Thiago Cesar de

    2014-06-01

    The zirconium-93 is a long-lived pure β-particle-emitting radionuclide produced from {sup 235}U fission and from neutron activation of the stable isotope {sup 92}Zr and thus occurring as one of the radionuclides found in nuclear reactors. Due to its long half life, {sup 93}Zr is one of the radionuclides of interest for the performance of assessment studies of waste storage or disposal. Measurement of {sup 93}Zr is difficult owing to its trace level concentration and its low activity in nuclear wastes and further because its certified standards are not frequently available. The aim of this work was to develop a selective radiochemical separation methodology for the determination of {sup 93}Zr in nuclear waste and analyze it by Liquid Scintillation Counting (LSC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). To set up the radiochemical separation procedure for zirconium, a tracer solution of {sup 95}Zr and its 724 keV γ-ray measurements by γ- spectrometry were used in order to follow the behavior of zirconium during the radiochemical separation. For the LSC technique a {sup 55}Fe solution, which is one of the major interfering measures zirconium, was used to verify the decontamination factor during the separation process. The efficiency detection for {sup 63}Ni was used to determination of {sup 93}Zr activity in the matrices analyzed. The limit of detection of the 0.05 Bq 1{sup −1} was obtained for {sup 63}Ni standard solutions by using a sample:cocktail ratio of 3:17 mL for Optiphase Hisafe 3 cocktail. For the ICP-MS technique a zirconium stable solution was used to verify the zirconium behavior and recovery during radiochemical separation and a solution of Ba, Co, Eu, Fe, Mn, Nb, Sr and Y was used to verify the decontamination factor during the separation process. A standard solution {sup 93}Nb as isotope for determining the {sup 93}Zr by ICP-MS was used for calibration and analysis. The detection limit of 0.039 ppb was obtained for the standard

  11. Determination of uranium isotopes ({sup 235}U, {sup 238}U) and trace elements (Cd, Pb, Cu and As) in bottled drinking water by Icp-SFMS; Determinacion de isotopos de uranio ({sup 235}U, {sup 238}U) y elementos traza (Cd, Pb, Cu y As) en agua embotellada para beber por ICP-SFMS

    Energy Technology Data Exchange (ETDEWEB)

    Lara A, N.; Hernandez M, H.; Romero G, E. T.; Kuri de la C, A.; Perez B, M. A., E-mail: nancy.lara@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    In the present work we propose an optimized method for the quantification of uranium isotopes ({sup 235}U, 2{sup 38}U) and the elements Cd, Pb, Cu and As in bottled water for drinking at trace levels of concentration. Based on the multi-element detection capability, the high sensitivity and resolution that the Mass Spectrometry with Magnetic Sector with Inductively Coupled Plasma Source (Icp-SFMS) technique offers; the high, medium and low resolution analysis conditions for the elements under study were established and optimized using and Element 2/Xr equipment and the 23 multi-elemental Certified Reference Material (CRM). The analysis method was validated using the standard reference material Nist 1643d and CRM mono-elemental s as external standards for the quantification of the analytes. Samples, targets and CRM were acidified with 2% of HNO{sub 3} and analyzed without pretreatment under the established analysis conditions. The results obtained show concentrations of {sup 235}U, {sup 238}U, {sup 111}Cd, {sup 208}Pb, {sup 63}Cu and {sup 75}As in the range of μg L{sup -1}, the linearity obtained from the calibration curves for each element has correlation coefficients < 0.99 in all cases, the accuracy of the method in terms of percent relative standard deviation (RSD %) was less than 5%, the mean recovery rate of Nist 1643d ranged from 96.46% to 101.12%. The optimization of the method guarantees the stability and calibration of the equipment throughout the analysis, as well as the ability to resolve interferences. In conclusion, the method proposed using Icp-SFMS offers the advantages of being fast and simple for the multi-elemental analysis in water at trace levels, with low limits of quantification and detection, with good linearity, accuracy, precision and reproducibility to a degree of reliability of 95%. (Author)

  12. AE Recorder Characteristics and Development.

    Energy Technology Data Exchange (ETDEWEB)

    Partridge, Michael E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Curtis, Shane Keawe [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); McGrogan, David Paul [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    The Anomalous Environment Recorder (AE Recorder) provides a robust data recording capability for multiple high-shock applications including earth penetrators. The AE Recorder, packaged as a 2.4" di ameter cylinder 3" tall, acquires 12 accelerometer, 2 auxiliary, and 6 discrete signal channels at 250k samples / second. Recording depth is 213 seconds plus 75ms of pre-trigger data. The mechanical, electrical, and firmware are described as well as support electro nics designed for the first use of the recorder.

  13. Mineral distribution in rice: Measurement by Microwave Plasma Atomic Emission Spectroscopy (MP-AES)

    International Nuclear Information System (INIS)

    Ramos, Nerissa C.; Ramos, R.G.A.; Quirit, L.L.; Arcilla, C.A.

    2015-01-01

    Microwave Plasma Atomic Emission Spectroscopy (MP-AES) is a new technology with comparable performance and sensitivity to Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Both instrument use plasma as the energy source that produces atomic and ionic emission lines. However, MP-AES uses nitrogen as the plasma gas instead of argon which is an additional expense for ICP-OES. Thus, MP-AES is more economical. This study quantified six essential minerals (Se, Zn, Fe, Cu, Mn and K) in rice using MP-AES. Hot plate digestion was used for sample extraction and the detection limit for each instrument was compared with respect to the requirement for routine analysis in rice. Black, red and non-pigmented rice samples were polished in various intervals to determine the concentration loss of minerals. The polishing time corresponds to the structure of the rice grains such as outer bran layer (0 to 15), inner bran layer (15 to 30), outer endosperm layer (30 to 45), and middle endosperm layer (45 to 60). Results of MP-AES analysis showed that black rice had all essential materials (except K) in high concentration at the outer bran layer. The red and non-pigmented rice samples on the other hand, contained high levels of Se, Zn, Fe, and Mn in the whole bran portion. After 25 seconds, the mineral concentrations remained constant. The concentration of Cu however, gave consistent value in all polishing intervals, hence Cu might be located in the inner endosperm layer. Results also showed that K was uniformly distributed in all samples where 5% loss was consistently observed for every polishing interval. Therefore, the concentration of K was also affected by polishing time. Thus, the new MP-AES technology with comparable performance to ICP-OES is a promising tool for routine analysis in rice. (author)

  14. Gas-phase sample introduction techniques for the determination of some non-metals by ICP-AES, MIP-AES AND ICP-MS

    International Nuclear Information System (INIS)

    Nakahara, Taketoshi

    2003-01-01

    Various gas-phase sample introduction methods in analytical atomic spectrometry have been documented for up to 30 elements, but only a few of these methods with less than one-third of the analytes exhibit adequate, competitive performance characteristics. Most attractive are the chemical systems based on (i) reactions in aqueous media, (ii) with fast kinetics of chemical vapor generation and easy stripping off of vapors from solution, (iii) reliable interference control, (iv) with high and reducible chemical yields of volatile products which are (v) readily atomized, excited or ionized in a plasma, so as to provide adequate sensitivity and low limits of detection (LOD). Some significant advantage of gas-phase sample introduction over the widely-used pneumatic nebulization of liquid (solution) samples are (1) high chemical yields and transport efficiency, (2) separation from troublesome matrices, (3) enrichment, (4) automation in flow injection and continuous flow mode, (5) good sample throughput rates, (6) competitive LODs and RSDs, (7) commercially available accessories, (8) economically affordable and (9) speciation potentialities. To the contrary, the major disadvantages and limitations are (1) complex, on line-chemistry involved, (2) specific sample pre-treatment required, (3) effect of oxidation and binding state of analyte, (4) chemical interferences, (5) foaming and aerosol formation, (6) numerous instrumental and chemical parameters for optimization, (7) applicability to a limited number of analytes, (8) limited linear ranges and (9) poor-multi-element capabilities.

  15. Evaluation of the metal contamination associated to the leachate in the Chururupe-Ilheus (Bahia State, Brazil) river by using INAA and ICP-MS; Avaliacao da contaminacao por metais associada ao despejo de chorume no rio Cururupe-Ilheus-BA utilizando INAA e ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Dalmazio, Ilza; Oliveira, Arno Heeren de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Menezes, Maria Angela de B.C. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil). Lab. de Radioquimica; Silva, Mario R. de S.; Vasconcelos, Danilo C.; Santos, Balbino L. dos [Universidade Estadual de Santa Cruz, Ilheus, BA (Brazil). Dept. de Ciencias Biologicas

    2002-07-01

    The site of this research is in Ilheus city located at Bahia State in Brazil. Residues generated by the urban activities from this city are collected and disposed at a place without sanitary control called ' Lixao do Cururupe' close to Cururupe river. The leachate from the water drainage through the mass of garbage flows into the river. This solution is rich in organic and inorganic pollutants. There is not any information about the environmental impact caused by this dump. The objective of this study is to evaluate the contamination caused by metals due to the presence of leachate into Rio Cururupe. Water, sediment and crustaceans (Ucides cordatus) samples were collected in different points considering the dump location. Extra samples were also taken in Rio Acuipe 20 km from Rio Cururupe for comparison. After appropriate treatment the samples were analyzed using the technique Instrumental Neutron Activation Analysis (INAA) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The parameters pH, temperature, conductivity, dissolved oxygen and Biochemistry Oxygen Demand from the water samples were also determined. (author)

  16. A Novel Recommendation To AES Limitation

    Directory of Open Access Journals (Sweden)

    Falguni Patel

    2017-07-01

    Full Text Available Among all available conventional encryption algorithms the AES Advanced Encryption Standard is the most secured and highly used algorithm. AES algorithm is widely used by variety of applications like Archive and Compression tools File Encryption Encryption File System Disk Partition Encryption Networking Signal Protocol among others. This paper highlights the Brute Force attack and Cryptanalysis attack on AES Algorithm. This paper also discusses about a novel recommendation of a combination model of AES Algorithm and Random-X Cipher.

  17. Attacks and countermeasures on AES and ECC

    DEFF Research Database (Denmark)

    Tange, Henrik; Andersen, Birger

    2013-01-01

    AES (Advanced Encryption Standard) is widely used in LTE and Wi-Fi communication systems. AES has recently been exposed to new attacks which have questioned the overall security of AES. The newest attack is a so called biclique attack, which is using the fact that the content of the state array...

  18. ICPES World Congress 2003

    Directory of Open Access Journals (Sweden)

    Chu-Pak Lau

    2002-04-01

    Full Text Available The XII World Congress on Cardiac Pacing and Electrophysiology is co-organised by the International Cardiac Pacing & Electrophysiology Society (ICPES and the Hong Kong College of Cardiology (HKCC. It will take place at the Hong Kong Convention and Exhibition Centre on February 19-22, 2003. The World Congress has been organized in various countries, including USA, France, The Netherlands, Japan, Canada, Austria, Israel, Argentina and Germany. The coming Congress is going to be held in the centre of Asia where East meets West – Hong Kong, which is now a Special Administrative Region of China since 1997. Hong Kong continues to enjoy a high degree of autonomy, and has remained an important center of finance, information technology, tourism, trade and exchange in Asia. In addition, it enjoys increasing interaction with the rapidly developing Mainland China. Developed with the assistance of a broadly represented International Scientific Advisory Committee, the scientific programme will feature 11 major topics - “Electrophysiology”, “Catheter Ablation”, “Pacing”, “Defibrillation”, “Pharmacology”, “Hybrid Therapy”, “Pediatric Arrhythmias”, “Arrhythmias for Allied Professionals”, “Genetics & Gene Therapy”, “ECG, Noninvasive Evaluation & Risk Stratification” and “Implantable Monitoring Devices”. It includes Plenary Sessions, Core Sessions, Expert Sessions, Featured Symposia, Live Demonstration, Teaching Courses, Abstract Presentations and Poster Sessions.

  19. Determinación de elementos minoritarios, traza y ultratraza en biopsias procedentes de pacientes con diferentes patologías tumorales mediante ETAAS, ICP-OES e ICP-MS utilizando extracción asistida por ultrasonidos y multigestión de bajo volumen

    OpenAIRE

    Millos Alfeiran, Jorge

    2012-01-01

    El objetivo principal de esta tesis doctoral es la determinación de metales minoritarios, traza y ultratraza en tejidos tumorales humanos mediante el desarrollo de metodologías analíticas adecuadas y robustas que permitan obtener resultados precisos y exactos, de manera que puedan ser aplicadas al análisis de rutina. En este sentido, se ha buscado la solución óptima a cada uno de los problemas planteados. Para llevar a cabo este objetivo se han evaluado la extracción ácida asistida por ult...

  20. Developing A/E Capabilities

    International Nuclear Information System (INIS)

    Gonzalez, A.; Gurbindo, J.

    1987-01-01

    During the last few years, the methods used by EMPRESARIOS AGRUPADOS and INITEC to perform Architect-Engineering work in Spain for nuclear projects has undergone a process of significant change in project management and engineering approaches. Specific practical examples of management techniques and design practices which represent a good record of results will be discussed. They are identified as areas of special interest in developing A/E capabilities for nuclear projects . Command of these areas should produce major payoffs in local participation and contribute to achieving real nuclear engineering capabities in the country. (author)

  1. Tecnología de fabricación de arrabio con inyección de combustibles y otros materiales por toberas en el horno alto. II parte. Inyección de carbón pulverizado (ICP

    Directory of Open Access Journals (Sweden)

    García, L.

    1998-06-01

    Full Text Available The technology of ironmaking with coal injection by tuyeres in the blast furnace is described. The influence of the main coal constituents in the furnace operation is analyzed. Information about the countries that employ this technology is given.

    Se describe la tecnología de fabricación de arrabio con inyección de carbón por toberas en el horno alto. Se analiza y comenta la influencia de los principales constituyentes del carbón en la operación del horno. Se ofrece información sobre los países que emplean esta tecnología.

  2. Infrared observations of AE Aquarii

    Science.gov (United States)

    Tanzi, E. G.; Chincarini, G.; Tarenghi, M.

    1981-01-01

    Broadband infrared observations of the cataclysmic variable AE Aquarii are reported. The observations were obtained in the J, H, K and L filters with the InSb photometer attached to the 1-m telescope of the European Southern Observatory. The infrared energy distribution observed from 0.35 to 3.5 microns for phase 0.5 suggests a spectral type of K5 V for the secondary and a distance to the system of approximately 70 pc if an absolute magnitude of 7.3 is assumed. Monitoring of the flux at 2.2 microns reveals a variability with an amplitude of approximately 0.3 magnitude over one third of the orbital period, the nature of which is under investigation.

  3. Biclique cryptanalysis of the full AES

    DEFF Research Database (Denmark)

    Bogdanov, Andrey; Khovratovich, Dmitry; Rechberger, Christian

    2011-01-01

    Since Rijndael was chosen as the Advanced Encryption Standard (AES), improving upon 7-round attacks on the 128-bit key variant (out of 10 rounds) or upon 8-round attacks on the 192/256-bit key variants (out of 12/14 rounds) has been one of the most difficult challenges in the cryptanalysis of block...... ciphers for more than a decade. In this paper, we present the novel technique of block cipher cryptanalysis with bicliques, which leads to the following results: The first key recovery method for the full AES-128 with computational complexity 2126.1. The first key recovery method for the full AES-192...... with computational complexity 2189.7. The first key recovery method for the full AES-256 with computational complexity 2254.4. Key recovery methods with lower complexity for the reduced-round versions of AES not considered before, including cryptanalysis of 8-round AES-128 with complexity 2124.9. Preimage search...

  4. [Determination of Arsenic in Food Package Aluminum by Ultrasound Assisted Solid Phase Extraction/ICP-AES].

    Science.gov (United States)

    Qin, Wen-xia; Gong, Qi; Li, Min; Deng, Li-xin; Mo, Li-shu; Li, Yan-lin

    2015-04-01

    Determination of arsenic in pure aluminum by inductively coupled plasma atomic emission spectrometry was interfered by aluminum matrix. The experiment showed that when the mass concentration of Al was greater than or equal to 5 000 times the As in the test solution, the measurement error was greater than 5%. In order to eliminate the interference, strong acid cation exchange fiber (SACEF) was used as solid phase extraction agent to adsorb Al(3+). The extraction conditions included amount of SACEF, extraction time, temperature and pH were investigated. The optimal extraction conditions were that 0.9000 g SACEF was used to extract the aluminum from the sample solution of pH 2.0 at 55 °C for 5 min with the ultrasonic assist, and in this case, the arsenic in the form of arsenic acid was not extracted and left in the solution for the determination. The results showed that after treating 10. 00 mL test solution containing 1.00 µg arsenic and 20.0 mg aluminum, arsenic did not lose. The mass concentration of residual aluminum in the raffinate was about 2,000 times the As, which had not interfered the determination of arsenic. The detection limit (3 s) was 0.027 µg · mL(-1) and quantification limit (10 s) was 0.0091 µg · mL(-1). The proposed method was successfully applied to the separation and determination of arsenic in the synthetic samples, the aluminum cans and the barbecue aluminum foil. Recovery was in the range of 98.3%-105% and RSD (n = 3) was in the range of 0.1%-4.3%. The results showed that the content of arsenic in the aluminum cans and the aluminum barbecue foil was below the limited value of national standard (GB/T 3190-2008).

  5. Investigation of ceramic materials using ICP-AES with external electrothermal vaporization

    International Nuclear Information System (INIS)

    Reisch, M.; Gartz, R.; Mazurkiewicz, M.; Nickel, H.

    1989-01-01

    The evaporation and excitation processes for several trace elements in ceramic powders are studied. The advantages of an electrothermal vaporization are the easier preparation, no dilution and a shorter experiment duration. The investigated ceramic powders consist of synthetic mixtures including the systems Al 2 O 3 -SiO 2 and Al 2 O 3 -MgO. The trace elements are bound as oxides. The evaporation is monitored by 59 Fe and 115 Cd. Since the evaporation rates are measured in addition to line intensities, the influence of various parameters on evaporation as well as on excitation processes can be individually examined. The influence of matrix composition is determined. It is found that melting and sintering processes of the matrix are of great importance for the evaporation of trace elements. Thus the best results are obtained when trace elements evaporate below the melting temperature of the matrix. Therefore the addition of thermochemical substances is necessary for several elements of low volatility. In the case of highly volatile elements, for example Cd, additives seemed to have only a small influence on the volatilization rate. Accordingly, only the excitation is affected. For example, the evaporation rate of Cd is constant through the whole Al 2 O 3 -MgO system. The measured line intensity of Cd is also constant within a large range of MgO content. The evaporation rate and line intensity of Fe decrease linearly with MgO concentration. (author)

  6. ICP experiments more durable pavements

    International Nuclear Information System (INIS)

    Carta Petrolera

    1994-01-01

    A new asphalts technology that will make more durable the pavement in the highways and roads of the cities of Colombia investigates the Colombian Institute of the Petroleum ICP. The project that will have important incidence in the solution of one of the main problems in the roads of cities like Bogota, is only one of the 35 investigation programs and application of new technologies that with relationship to the sector of the hydrocarbons and its influence branches the ICP advances. The investigation looks for to elevate the current average of useful life of the pavements, with that it would be reached a standard that has the developed countries in this field

  7. Chromosome isolation by flow sorting in Aegilops umbellulata and Ae. comosa and their allotetraploid hybrids Ae. biuncialis and Ae. geniculata.

    Directory of Open Access Journals (Sweden)

    István Molnár

    Full Text Available This study evaluates the potential of flow cytometry for chromosome sorting in two wild diploid wheats Aegilops umbellulata and Ae. comosa and their natural allotetraploid hybrids Ae. biuncialis and Ae. geniculata. Flow karyotypes obtained after the analysis of DAPI-stained chromosomes were characterized and content of chromosome peaks was determined. Peaks of chromosome 1U could be discriminated in flow karyotypes of Ae. umbellulata and Ae. biuncialis and the chromosome could be sorted with purities exceeding 95%. The remaining chromosomes formed composite peaks and could be sorted in groups of two to four. Twenty four wheat SSR markers were tested for their position on chromosomes of Ae. umbellulata and Ae. comosa using PCR on DNA amplified from flow-sorted chromosomes and genomic DNA of wheat-Ae. geniculata addition lines, respectively. Six SSR markers were located on particular Aegilops chromosomes using sorted chromosomes, thus confirming the usefulness of this approach for physical mapping. The SSR markers are suitable for marker assisted selection of wheat-Aegilops introgression lines. The results obtained in this work provide new opportunities for dissecting genomes of wild relatives of wheat with the aim to assist in alien gene transfer and discovery of novel genes for wheat improvement.

  8. [Progress in the application of laser ablation ICP-MS to surface microanalysis in material science].

    Science.gov (United States)

    Zhang, Yong; Jia, Yun-hai; Chen, Ji-wen; Shen, Xue-jing; Liu, Ying; Zhao, Leiz; Li, Dong-ling; Hang, Peng-cheng; Zhao, Zhen; Fan, Wan-lun; Wang, Hai-zhou

    2014-08-01

    In the present paper, apparatus and theory of surface analysis is introduced, and the progress in the application of laser ablation ICP-MS to microanalysis in ferrous, nonferrous and semiconductor field is reviewed in detail. Compared with traditional surface analytical tools, such as SEM/EDS (scanning electron microscopy/energy dispersive spectrum), EPMA (electron probe microanalysis analysis), AES (auger energy spectrum), etc. the advantage is little or no sample preparation, adjustable spatial resolution according to analytical demand, multi-element analysis and high sensitivity. It is now a powerful complementary method to traditional surface analytical tool. With the development of LA-ICP-MS technology maturing, more and more analytical workers will use this powerful tool in the future, and LA-ICP-MS will be a super star in elemental analysis field just like LIBS (Laser-induced breakdown spectroscopy).

  9. Dynamic AES – Extending the Lifetime?

    DEFF Research Database (Denmark)

    Tange, Henrik; Andersen, Birger

    2014-01-01

    proven that AES is vulnerable to side-channelattacks, related sub-key attacks and biclicque attacks. This paper introducesa new dynamic version of AES where the main flow is depending on theTNAF (τ -adic Non-Adjacent Form) value. This new approach can preventside-channel attacks, related sub-key attacks...... and biclique attacks....

  10. AES in deficit on Georgian trade

    International Nuclear Information System (INIS)

    TREND

    2003-01-01

    According to Vedomosti journal Russian state energy company RAO JES Rossii paid for Georgian assets acquisition to American company AES only 23 million USD, what is less than a tenth of sum which AES had originally paid for it. Thus total transaction value including debts reached 80 millions USD. But internal documents of American AES confirm that Americans paid 260 millions USD for Georgian assets and they took besides over 60 millions USD of obligations. Russians bought Georgian AES assets through Finnish filial Nordic Oy. Thus they obtained 75 per cent share in Telasi company which operates distributive network in Tbilisi, two blocks of plant in Tbilisi and half share in AES-Transenergy company which exports electric energy from Georgia to Turkey. RAO JES besides got managerial laws on Hramesi company which owns two water plants. Russian company controls one fifth of production and 35 per cent of electric energy sale in Georgia by these assets

  11. In situ isotopic analyses of U and Pb in zircon by remotely operated SHRIMP II, and Hf by LA-ICP-MS: an example of dating and genetic evolution of zircon by {sup 176}Hf/{sup 177}Hf from the Ita Quarry in the Atuba Complex, SE, Brazil; Analises in situ de U e Pb em zircao por SRIMP II por controle remoto e de Hf por LA-ICP-MS: um exemplo de datacao e da evolucao genetica de zircao atraves da razao {sup 176}Hf/{sup 177} em amostra da Pedreira Ita no Complexo Atuba, SE, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Sato, K.; Siga Junior, Oswaldo; McReath, Ian; Sproesser, Walter; Basei, Miguel Angelo Stipp [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Geociencias. Centro de Pesquisas Geocronologicas], e-mail: keisato@usp.br, e-mail: osigajr@usp.br, e-mail: ianmcr@usp.br, e-mail: wmspres@usp.br, e-mail: baseimas@usp.br; Silva, Josiane Aline da [Universidade de Sao Paulo (USP), SP (Brazil). Programa de Pos-graduacao em Geoquimica e Geotectonica; Dunyi, Liu [Institute of Geology, Beijing (China); Iizuka, Takafumi; Rino, Shuji; Hirata, Takafumi [Tokyo Institute of Technology, Tokyo (Japan)

    2009-10-15

    Remotely-operated SHRIMP dating of zircon is an interesting alternative for dating of zircon crystals. Although it does not represent any technical progress of the geochronological method using the U-Pb system in zircon it is a very useful and cheap facility. The procedure was first used for mass spectrometric analyses involving two international laboratories in Sao Paulo, Brazil and Beijing, China. It was applied to samples of three gneiss-migmatitic rocks from the Ita quarry in the Atuba Complex (located between the Luis Alves and the Apiai Domain) to test previous controversial hypotheses about its evolution. The presence of important archaean and paleo proterozoic components in the complex is confirmed by analyses of zircon found in probably neo proterozoic leucosomes. Diorite intrusion also occurred during the neo proterozoic, associated with the 0.6Ga continental collisions involved in the assembly of Gondwana. The determination of Hf isotope ratios by LA-ICP/MS represents a new option for checking the relative importance of mantle ({epsilon}{sub Hf} > 0) and crustal contributions (({epsilon}{sub Hf} < 0) during the growth of the zircon crystals. While the archaean component in the complex was derived from the mantle ({epsilon}{sub Hf} + 1.5 to + 8.7) the paleo proterozoic component had a crustal contribution ({epsilon}{sub Hf} - 9.1 to -10.1). (author)

  12. Characterisation of Supra- and Infratentorial ICP Profiles.

    Science.gov (United States)

    Moyse, Emmanuel; Ros, Maxime; Marhar, Fouad; Swider, Pascal; Schmidt, Eric Albert

    2016-01-01

    In pathophysiology and clinical practice, the intracranial pressure (ICP) profiles in the supratentorial and infratentorial compartments are unclear. We know that the pressure within the skull is unevenly distributed, with demonstrated ICP gradients. We recorded and characterised the supra- and infratentorial ICP patterns to understand what drives the transtentorial ICP gradient.A 70-year-old man was operated on for acute cerebellar infarction. One supratentorial probe and one cerebellar probe were implanted. Both signals were recorded concurrently and analysed off-line. We calculated mean ICP, ICP pulse amplitude, respiratory waves, slow waves and the RAP index of supra- and infratentorial ICP signals. Then, we measured transtentorial difference and performed correlation analysis for every index.Supratentorial ICP mean was 8.5 mmHg lower than infratentorial ICP, but the difference lessens for higher values. Both signals across the tentorium showed close correlation. Supra- and infratentorial pulse amplitude, respiratory waves and slow waves also showed a high degree of correlation. The compensatory reserve (RAP) showed good correlation. In this case report, we demonstrate that the mean value of ICP is higher in the posterior fossa, with a strong correlation across the tentorium. All other ICP-derived parameters display a symmetrical profile.

  13. Comportamento de Aedes albopictus e de Ae. scapularis adultos (Diptera: Culicidae no Sudeste do Brasil Adults Aedes albopictus and Ae. scapularis behavior (Diptera: Culidae in Southeastern Brazil

    Directory of Open Access Journals (Sweden)

    Oswaldo Paulo Forattini

    2000-10-01

    Full Text Available OBJETIVO: Observar e comparar o comportamento das espécies de Aedes albopictus e de Ae. scapularis, na localidade de Pedrinhas, litoral sul do Estado de São Paulo, Brasil. MÉTODOS: As observações foram feitas de outubro de 1996 a janeiro de 2000. Foram realizadas coletas sistemáticas de formas adultas mediante a utilização de isca humana, aspirações ambientais e armadilha tipo Shannon. A domiciliação foi estimada pelo índice de Nuorteva e pela razão de sinantropia. RESULTADOS: Foram feitas 87 coletas diurnas, com a obtenção de 872 adultos fêmeas. As médias de Williams', multiplicadas por 100, foram de 118 e 21 para Ae. albopictus nos horários de 7h às 18h e de 18h às 20h, respectivamente. Quanto a Ae. scapularis, foram de 100 e 106 nos mesmos períodos. Esse último revelou pico de atividade crepuscular vespertina. Na aspiração de abrigos, obteve-se o total de 1.124 espécimens, dos quais 226 Ae. albopictus e 898 Ae. scapularis. O período de janeiro a maio correspondeu ao de maior rendimento para ambos os mosquitos. Quanto à armadilha de Shannon, as coletas realizadas na mata revelaram a ausência de Ae. albopictus. No que concerne à domiciliação, esse último mostrou os maiores valores de índices, enquanto Ae. scapularis revelou comportamento de tipo ubiquista. CONCLUSÕES: Os resultados confirmam outras observações, permitindo levantar hipóteses. Em relação a Ae. scapularis, sugere-se que possa existir fenômeno de diapausa das fêmeas no período verão-outono, a qual cessaria no inverno-primavera quando então a atividade seria retomada. Quanto a Ae. albopictus, os dados sugerem que se trata de população em processo adaptativo ao novo ambiente.OBJECTIVE: Aedes albopictus and Ae. scapularis were found living together in the Pedrinhas Village, Southeastern of São Paulo State, Brazil. This finding was a good opportunity to make observations about the mosquitoes' behavior. METHODS: From October 1996 to

  14. AE/VCE Unconfirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  15. AE/VCE Confirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  16. ICP Mass and Optical Emission Spectrometry of Ore Samples Containing Rare Earth Elements

    International Nuclear Information System (INIS)

    Mohammed, A.E.W.M.

    2013-01-01

    Inductively Coupled Plasma Optical Emission and Mass Spectrometry (ICP-OES and ICPMS) are widely accepted as a rapid and sensitive techniques for Rare Earth Elements (REEs) analysis of geological samples. However, the achievable accuracy of these techniques are seriously limited by the problem of matrix interferences. In this study, matrix effects in ICP-AES were addressed using two approaches. In the first approach, the mechanisms of matrix interferences and analyte excitation were elucidated fundamentally. First, matrix effects from a comprehensive list of thirty-nine elements were investigated. It was confirmed that matrix elements with low second (instead of the widely reported first) ionization potentials (IP) produce a stronger matrix effect in all cases. Another critical parameter defining the severity of the matrix effect was found to be the availability of low-lying energy levels in the doubly charged matrix ion. Penning ionization followed by ion electron recombination through successive cycles is proposed as the mechanism for the more severe matrix effects caused by low second-IP matrices. In the second approach ICP-OES and ICP-MS are applied in this study for the analysis of Rare Earth Elements of two selected standard reference samples namely AGV-2 and BCR-2 beside a fluorspar geological sample (G-9 sample). Effective procedures are developed to avoid the spectral interference from matrix elements by using ion exchange resin Amberlite IR-120 before determination of REEs using ICP-OES and ICPMS. The potential of the method is evaluated by analysis of Certified Reference Materials (AGV-2 and BCR-2). Results obtained by ICP-MS show that experimental data are in agreement with the certified values and their values could be used as a quantitative data. The results obtained using ICP-OES were compared and discussed.

  17. Indigenous development of a glove box for ICP-OES

    International Nuclear Information System (INIS)

    Khan, A.M.; Anwar, M.K.; Bangash, M.A.

    2011-01-01

    Chemical analysis involving nuclear materials are bound to be carried out in safety enclosures like glove box, fume hood etc. whereas chemical analysis which produce mist or vapors of these materials like Atomic absorption Spectrometry, Flame photometry and ICP-AE spectrometry etc. must be performed in a glove box with HEPA filters on exhaust. These instruments with glove box adaptation are rare and impossible to import for our country. An ICP-OES, model Integra-XL of GBC-Australia was purchased in 2008 for chemical analysis of similar materials. As usual it was manufactured to operate in open atmosphere. The required analytical work could not be done in open atmosphere due to active nature of the samples. Therefore modification and glove box (GB) adaptation was required. Although large in size yet difficult to adapt for GB, the instrument had to be modified to a large extent as only sample handling part of the instrument had to placed inside GB, leaving rest of the instrument available for later repair/maintenance work. Different options were considered for modification keeping in mind the isolation and negative pressure inside the GB and maintaining the integrity of the instrument. One of such option was finalized which involved shifting the optic tank etc. A no of isolation gadgets were designed and fabricated locally. This indigenization has saved some handsome amount of foreign exchange. (Author)

  18. Clinical epidemiology of human AE in Europe.

    Science.gov (United States)

    Vuitton, D A; Demonmerot, F; Knapp, J; Richou, C; Grenouillet, F; Chauchet, A; Vuitton, L; Bresson-Hadni, S; Millon, L

    2015-10-30

    This review gives a critical update of the situation regarding alveolar echinococcosis (AE) in Europe in humans, based on existing publications and on findings of national and European surveillance systems. All sources point to an increase in human cases of AE in the "historic endemic areas" of Europe, namely Germany, Switzerland, Austria and France and to the emergence of human cases in countries where the disease had never been recognised until the end of the 20th century, especially in central-eastern and Baltic countries. Both increase and emergence could be only due to methodological biases; this point is discussed in the review. One explanation may be given by changes in the animal reservoir of the parasite, Echinococcus multilocularis (increase in the global population of foxes in Europe and its urbanisation, as well as a possible increased involvement of pet animals as definitive infectious hosts). The review also focuses onto 2 more original approaches: (1) how changes in therapeutic attitudes toward malignant and chronic inflammatory diseases may affect the epidemiology of AE in the future in Europe, since a recent survey of such cases in France showed the emergence of AE in patients with immune suppression since the beginning of the 21st century; (2) how setting a network of referral centres in Europe based on common studies on the care management of patients might contribute to a better knowledge of AE epidemiology in the future. Copyright © 2015. Published by Elsevier B.V.

  19. 15 CFR 758.2 - Automated Export System (AES).

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Automated Export System (AES). 758.2... CLEARANCE REQUIREMENTS § 758.2 Automated Export System (AES). The Census Bureau's Foreign Trade Statistics...) electronically using the Automated Export System (AES). In order to use AES, you must apply directly to the...

  20. ICP27-dependent resistance of herpes simplex virus type 1 to leptomycin B is associated with enhanced nuclear localization of ICP4 and ICP0

    International Nuclear Information System (INIS)

    Lengyel, Joy; Strain, Anna K.; Perkins, Keith D.; Rice, Stephen A.

    2006-01-01

    It was previously shown that herpes simplex virus type 1 (HSV-1) is sensitive to leptomycin B (LMB), an inhibitor of nuclear export factor CRM1, and that a single methionine to threonine change at residue 50 (M50T) of viral immediate-early (IE) protein ICP27 can confer LMB resistance. In this work, we show that deletion of residues 21-63 from ICP27 can also confer LMB resistance. We further show that neither the M50T mutation nor the presence of LMB affects the nuclear shuttling activity of ICP27, suggesting that another function of ICP27 determines LMB resistance. A possible clue to this function emerged when it was discovered that LMB treatment of HSV-1-infected cells dramatically enhances the cytoplasmic accumulation of two other IE proteins, ICP0 and ICP4. This effect is completely dependent on ICP27 and is reversed in cells infected with LMB-resistant mutants. Moreover, LMB-resistant mutations in ICP27 enhance the nuclear localization of ICP0 and ICP4 even in the absence of LMB, and this effect can be discerned in transfected cells. Thus, the same amino (N)-terminal region of ICP27 that determines sensitivity to LMB also enhances ICP27's previously documented ability to promote the cytoplasmic accumulation of ICP4 and ICP0. We speculate that ICP27's effects on ICP4 and ICP0 may contribute to HSV-1 LMB sensitivity

  1. AES ALGORITHM IMPLEMENTATION IN PROGRAMMING LANGUAGES

    Directory of Open Access Journals (Sweden)

    Luminiţa DEFTA

    2010-12-01

    Full Text Available Information encryption represents the usage of an algorithm to convert an unknown message into an encrypted one. It is used to protect the data against unauthorized access. Protected data can be stored on a media device or can be transmitted through the network. In this paper we describe a concrete implementation of the AES algorithm in the Java programming language (available from Java Development Kit 6 libraries and C (using the OpenSSL library. AES (Advanced Encryption Standard is an asymmetric key encryption algorithm formally adopted by the U.S. government and was elected after a long process of standardization.

  2. Study, analysis, assess and compare the nuclear engineering systems of nuclear power plant with different reactor types VVER-1000, namely AES-91, AES-92 and AES-2006

    International Nuclear Information System (INIS)

    Le Van Hong; Tran Chi Thanh; Hoang Minh Giang; Le Dai Dien; Nguyen Nhi Dien; Nguyen Minh Tuan

    2015-01-01

    On November 25, 2009, in Hanoi, the National Assembly had been approved the resolution about policy for investment of nuclear power project in Ninh Thuan province which include two sites, each site has two units with power around 1000 MWe. For the nuclear power project at Ninh Thuan 1, Vietnam Government signed the Joint-Governmental Agreement with Russian Government for building the nuclear power plant with reactor type VVER. At present time, the Russian Consultant proposed four reactor technologies can be used for Ninh Thuan 1 project, namely: AES-91, AES-92, AES-2006/V491 and AES-2006/V392M. This report presents the main reactor engineering systems of nuclear power plants with VVER-1000/1200. The results from analysis, comparison and assessment between the designs of AES-91, AES-92 and AES-2006 are also presented. The obtained results show that the type AES-2006 is appropriate selection for Vietnam. (author)

  3. Producción de endoproteasa ácida extracelular (mrAE) por el hongo fitopatógeno Moniliophthora roreri cultivado en el sistema de fermentación en el estado sólido con bagazo de caña de azúcar como sustrato.

    OpenAIRE

    Soberano Mayo, María Isabel

    2012-01-01

    Las proteasas son enzimas industriales muy importantes y comprenden alrededor del 60% de las enzimas comerciales en el mundo. Dos terceras partes de estas proteasas son de fuentes microbianas, principalmente de origen fúngico. El presente trabajo tuvo como objetivos estudiar la cinética de producción de enzima endoproteasa ácida extracelular (mrAe) del hongo fitopatógeno Moniliophthora roreri MRO1, cultivado en sistema de fermentación en estado sólido (FES), utilizando como sustrato inductor ...

  4. Quantification of {sup 232}Th, {sup 234}U, {sup 235}U and {sup 238}U in river mollusks by magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS); Cuantificacion de {sup 232}Th, {sup 234}U, {sup 235}U y {sup 238}U en moluscos de rios por espectrometria de masas de sector magnetico con fuente de plasma acoplado inductivamente (ICP-SFMS)

    Energy Technology Data Exchange (ETDEWEB)

    Arevalo R, D. L.; Hernandez M, H.; Romero G, E. T.; Lara A, N. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Alfaro de la T, M. C., E-mail: arevalo0591@hotmail.com [Universidad Autonoma de San Luis Potosi, Dr. Salvador Nava s/n, Zona Universitaria, 78290 San Luis Potosi, SLP (Mexico)

    2016-09-15

    The present work deals with the methodology established for the quantification of {sup 232}Th, {sup 234}U, {sup 238}U and {sup 235}U in the shell of gastropod mollusks collected in the rivers Valles, Coy and Axtla of San Luis Potosi, Mexico, which belong to the Panuco River basin; these rivers have as main source of pollution the discharge of municipal sewage, waste from small industries, agricultural and cattle residues and from natural sources. Conventional methods for measuring radio-nuclides are confronted with certain conditions related to the requirement in measurement, basically in the characterization that is related to the concepts of precision and accuracy. The analysis of the gastropod mollusk shell was performed by the Icp-SFMS technique; the main advantages of this technique lie in the isotope quantification capacity, the high precision and the low limits of detection, in this study are very important because these elements are in concentrations between ppb and ppt. This technique allowed the analysis of the samples having a complex matrix by the presence CaCO{sub 3} minimizing the interferences thanks to the ionization efficiency of the Ar plasma. For the species Pachychilus monachus were found concentrations of {sup 232}Th of 0.16-5.37 μg/g and of total U of 0.101-4.081 μg/g being this species where the highest values of total U were found. For Thiara (melanoids) tuberculata the lowest values were found among the different species ({sup 232}Th 0.61-3.61 μg/g and total U 0.006-0.042 μg/g), for Pachychilus suturalis, values of {sup 232}Th of 0.58-6.4 μg/g and for Pachychilus sp. were found between 0.26-7.62 μg/g and for total U values between 0.28-3.33 μg/g. The method offers several advantages: speed, good precision, low values of quantification limits and high sensitivity in the measurement of radio-nuclides and heavy metals. (Author)

  5. AES Water Architecture Study Interim Results

    Science.gov (United States)

    Sarguisingh, Miriam J.

    2012-01-01

    The mission of the Advanced Exploration System (AES) Water Recovery Project (WRP) is to develop advanced water recovery systems in order to enable NASA human exploration missions beyond low earth orbit (LEO). The primary objective of the AES WRP is to develop water recovery technologies critical to near term missions beyond LEO. The secondary objective is to continue to advance mid-readiness level technologies to support future NASA missions. An effort is being undertaken to establish the architecture for the AES Water Recovery System (WRS) that meets both near and long term objectives. The resultant architecture will be used to guide future technical planning, establish a baseline development roadmap for technology infusion, and establish baseline assumptions for integrated ground and on-orbit environmental control and life support systems (ECLSS) definition. This study is being performed in three phases. Phase I of this study established the scope of the study through definition of the mission requirements and constraints, as well as indentifying all possible WRS configurations that meet the mission requirements. Phase II of this study focused on the near term space exploration objectives by establishing an ISS-derived reference schematic for long-duration (>180 day) in-space habitation. Phase III will focus on the long term space exploration objectives, trading the viable WRS configurations identified in Phase I to identify the ideal exploration WRS. The results of Phases I and II are discussed in this paper.

  6. Metal RIE 2: Unaxis SHUTTLELINE ICP

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Unaxis ICP EtcherChlorine-based system utilizing Boron Trichloride and Chlorine to etch metals and III-V group materials on planar substrates...

  7. AE Test of Calcareous Sands with Particle Rushing

    Directory of Open Access Journals (Sweden)

    Tan Fengyi

    2017-08-01

    Full Text Available The particle of calcareous sands was forced to crush, then the energy from the crushing was released by the form of sound waves. Therefore the AE technique was used to detect the calcareous sands AE signal when it crushed. by to study the AE characteristics, the mechanics of calcareous sands was studied. Study showed that: (1 there was the AE activities on the low confining pressure condition at the beginnig of test, (2 there was more and more AE activities with the continuing of test until to the end, (3 the calcareous sands’ AE activities was on the whole testing, (4 the calcareous sands’ particle crushing and mutual friction played different roles for its AE activities. Then the AE model based on the calcarous sands’ particle crushing was discussed.

  8. 22 CFR 120.30 - The Automated Export System (AES).

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false The Automated Export System (AES). 120.30... DEFINITIONS § 120.30 The Automated Export System (AES). The Automated Export System (AES) is the Department of... system for collection of export data for the Department of State. In accordance with this subchapter U.S...

  9. Application of XRF methods for multielemental analysis of lichen samples collected in Havana City. Comparison with ICP-AES, ICP-MS and FAAS

    International Nuclear Information System (INIS)

    Herrero Fernandez, Zahily; Estevez Alvarez, Juan R.; Montero Alvarez, Alfredo; Pupo Gonzalez, Ivan; Ortueta Milan, Marvic; Mesa Perez, Guillermo; Leyva Bombuse, Dennys; Rodriguez Gonzalez, Maydel; Hernandez Torres, Debora; Padilla Alvarez, Roman; Quejido Cabezas, Alberto J.; Rucandio Saez, Maria I.; Fernandez Diaz, Marta

    2011-01-01

    This paper presents the results of the analysis of Ca, Fe, Zn, Br, Rb, Sr and Pb in samples of lichens used as biomonitors of air pollution collecting in Havana City during 2009-2010. Two different X-Ray Fluorescence methods were used. First, a combination of Si (Li) detector with an annular 109Cd as primary excitation source was employed. The second system consisted in a Mo X-ray tube with a secondary target of Molybdenum and a X-PIPS detector. In both configurations, the correction of matrix effects was achieved by using the Compton scattering peak. The quantification was performed using calibration curves obtained from different biological Certified Reference Materials. The determination of elements by Inductively Coupled Plasma-Atomic Emission Spectrometry, Inductively Coupled Plasma-Mass Spectrometry and Flame Atomic Absorption Spectrophotometry was carried out in order to evaluate the reliability of XRF methods. No significant differences were found between the obtained results by the different techniques. The levels of concentration of the analyzed elements in the lichens in 2009 and 2010 respectively were similar. The elemental distribution patters obtained for each metal were associated with different sources of contamination. (Author)

  10. HDE 323771: a new Herbig Ae star

    International Nuclear Information System (INIS)

    Persi, P.; Polcaro, V.F.; Viotti, R.

    1991-01-01

    From an analysis of the blue and red spectrum, and a study of the energy distribution from the optical up to the far infrared, we identify HDE 323771 as a new PMS Herbig Ae star. The P Cygni line profiles observed in the Balmer and Fe II lines indicate the presence of a stellar wind with a velocity of about 250-350 km s -1 . An upper limit of mass loss rate is derived from the observed upper limit for the Br γ luminosity. The near-IR images and the IR energy distribution indicate the presence of an extended circumstellar dust envelope with a temperature of about 1500 K. (author)

  11. Effect of ECAP processing on corrosion resistance of AE21 and AE42 magnesium alloys

    Science.gov (United States)

    Minárik, P.; Král, R.; Janeček, M.

    2013-09-01

    Corrosion properties of AE21 and AE42 magnesium alloys were investigated in the extruded state and after subsequent 8 passes of Equal Channel Angular Pressing (ECAP) via route Bc, by Electrochemical Impedance Spectroscopy (EIS) in 0.1 M NaCl solution. The resulting microstructure was observed by the Transmission Electron Microscope (TEM) and the Scanning Electron Microscope (SEM). Corrosion layer created after 7 days of immersion was observed by (SEM) in order to explain different evolution of the corrosion resistance after ECAP processing in both alloys. It was found that Al-rich Al11RE3 dispersed particles (present in both alloys) strongly influence the corrosion process and enhance the corrosion resistance. Ultra-fine grained structure was found to reduce the corrosion resistance in AE21. On the other hand, the microstructure of AE42 after ECAP and particularly the better distribution of the alloying elements in the matrix enhance the corrosion resistance when compared to the extruded material.

  12. Effect of ECAP processing on corrosion resistance of AE21 and AE42 magnesium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Minárik, P., E-mail: peter.minarik@mff.cuni.cz [Charles University, Department of Physics of Materials, Prague (Czech Republic); Král, R.; Janeček, M. [Charles University, Department of Physics of Materials, Prague (Czech Republic)

    2013-09-15

    Corrosion properties of AE21 and AE42 magnesium alloys were investigated in the extruded state and after subsequent 8 passes of Equal Channel Angular Pressing (ECAP) via route Bc, by Electrochemical Impedance Spectroscopy (EIS) in 0.1 M NaCl solution. The resulting microstructure was observed by the Transmission Electron Microscope (TEM) and the Scanning Electron Microscope (SEM). Corrosion layer created after 7 days of immersion was observed by (SEM) in order to explain different evolution of the corrosion resistance after ECAP processing in both alloys. It was found that Al-rich Al11RE3 dispersed particles (present in both alloys) strongly influence the corrosion process and enhance the corrosion resistance. Ultra-fine grained structure was found to reduce the corrosion resistance in AE21. On the other hand, the microstructure of AE42 after ECAP and particularly the better distribution of the alloying elements in the matrix enhance the corrosion resistance when compared to the extruded material.

  13. Effect of ECAP processing on corrosion resistance of AE21 and AE42 magnesium alloys

    International Nuclear Information System (INIS)

    Minárik, P.; Král, R.; Janeček, M.

    2013-01-01

    Corrosion properties of AE21 and AE42 magnesium alloys were investigated in the extruded state and after subsequent 8 passes of Equal Channel Angular Pressing (ECAP) via route Bc, by Electrochemical Impedance Spectroscopy (EIS) in 0.1 M NaCl solution. The resulting microstructure was observed by the Transmission Electron Microscope (TEM) and the Scanning Electron Microscope (SEM). Corrosion layer created after 7 days of immersion was observed by (SEM) in order to explain different evolution of the corrosion resistance after ECAP processing in both alloys. It was found that Al-rich Al11RE3 dispersed particles (present in both alloys) strongly influence the corrosion process and enhance the corrosion resistance. Ultra-fine grained structure was found to reduce the corrosion resistance in AE21. On the other hand, the microstructure of AE42 after ECAP and particularly the better distribution of the alloying elements in the matrix enhance the corrosion resistance when compared to the extruded material.

  14. Atomic-AES: A compact implementation of the AES encryption/decryption core

    DEFF Research Database (Denmark)

    Banik, Subhadeep; Bogdanov, Andrey; Regazzoni, Francesco

    2016-01-01

    The implementation of the AES encryption core by Moradi et al. at Eurocrypt 2011 is one of the smallest in terms of gate area. The circuit takes around 2400 gates and operates on an 8 bit datapath. However this is an encryption only core and unable to cater to block cipher modes like CBC and ELm...

  15. Analysis of elemental concentration using ICP-AES and pathogen indicator in drinking water of Qasim Abad, District Rawalpindi, Pakistan.

    Science.gov (United States)

    Sehar, Shama; Naz, Iffat; Ali, Naeem; Ahmed, Safia

    2013-02-01

    The present study was conducted to investigate drinking water quality (groundwater) from water samples taken from Qasim Abad, a locality of approximately 5,000 population, situated between twin cities Rawalpindi and Islamabad in Pakistan. The main sources of drinking water in this area are water bores which are dug upto the depth of 250-280 ft in almost every house. The study consists of the determination of physico-chemical properties, trace metals, heavy metals, rare earth elements and microbiological quality of drinking water. The data showed the variation of the investigated parameters in samples as follows: pH 6.75 to 8.70, electrical conductivity 540 to 855 μS/cm, total dissolved solids 325.46 to 515.23 ppm and dissolved oxygen 1.50 to 5.64 mg/L which are within the WHO guidelines for drinking water quality. The water samples were analysed for 30 elements (aluminium, iron, magnesium, manganese, silicon, zinc, molybdenum, titanium, chromium, nickel, tungsten, silver, arsenic, boron, barium, beryllium, cadmium, cobalt, copper, gallium, mercury, lanthanum, niobium, neodymium, lead, selenium, samarium, tin, vanadium and zirconium) by using inductively coupled plasma atomic emission spectroscopy. The organic contamination was detected in terms of most probable number (MPN) of faecal coliforms. Overall, elemental levels were lower than the recommended values but three water bores (B-1, B-6, B-7) had higher values of iron (1.6, 2.206, 0.65 ppm), two water bores (B-1, B-6) had higher values of aluminium (0.95, 1.92 ppm), respectively, and molybdenum was higher by 0.01 ppm only in one water bore (B-11). The total number of coliforms present in water samples was found to be within the prescribed limit of the WHO except for 5 out of 11 bore water samples (B-2, B-3, B-4, B-8, B-11), which were found in the range 5-35 MPN/100 mL, a consequence of infiltration of contaminated water (sewage) through cross connection, leakage points and back siphoning.

  16. An ICP-AES method for the determination of trace metals in uranium by solvent extraction using KSM-17

    International Nuclear Information System (INIS)

    Jacob, Mary; Radhakrishnan, K.; Dhami, P.S.; Kulkarni, V.T.; Joshi, M.V.; Patwardhan, A.B.; Ramanujam, A.; Mathur, J.N.

    1994-01-01

    This paper describes the studies carried out for the determination of trace metallic impurities in uranium solutions. Uranium matrix is separated from the impurity elements by its selective extraction using 2-ethylhexyl hydrogen 2-ethylhexyl phosphonate (KSM-17, equivalent to PC88A). The aqueous phase is analysed for trace impurities by inductively coupled argon plasma atomic emission spectrometry. The studies also include recovery of impurities at various acidities and spectral interferences of uranium over the analyte element channels. Based on the above studies, a method has been standardised for the analysis of nineteen elements in uranium solutions. The relative standard deviation of the method for various elements is in the range of +- 1-5%. (author). 7 refs., 8 tabs., 1 fig

  17. Determination of boron by ICP-AES in normal and malignant cells incubated 'in vitro' with fructose 10BPA

    International Nuclear Information System (INIS)

    Garavaglia, Ricardo N.; Farias, Silvia S.; Rodriguez, Ruben E.; Servant, Roberto E.; Liberman, Sara; Pisarev, Mario A.; Batistoni, Daniel A.

    1999-01-01

    This paper describes the development and optimization of methodology for total boron concentration in cell cultures coming from fixation and accumulation of this element by normal and malignant cells. On account of sample mass and low volume resulting from dilution, generally about 1 mL, a procedure for automatic injection of micro volumes was designed, developed and optimized. Iron interference was carefully studied. Linear calibration curves were obtained for 50 to 2500 ng B/mL range. Determination limits were 10 and 20 ng B/mL for B 249.772 nm and 249.677 nm, respectively. Repeatability, expressed as relative standard deviation was better than 5% for a 100 ng B/mL. Recovery of analyte added to real samples ranged between 95 and 103%. The method was applied to studies on F-98 cells (rat glioma) and normal glia in BNCT project frame. (author)

  18. 15 CFR Appendix D to Part 30 - AES Filing Citation, Exemption and Exclusion Legends

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false AES Filing Citation, Exemption and... Appendix D to Part 30—AES Filing Citation, Exemption and Exclusion Legends I. USML Proof of Filing Citation AES ITN Example: AES X20060101987654. II. AES Proof of Filing Citation subpart A § 30.7 AES ITN...

  19. Development of AE monitoring system for journal bearing

    International Nuclear Information System (INIS)

    Yoon, Dong Jin; Kwon, Oh Yang; Chung, Min Hwa

    1994-01-01

    For the purpose of monitoring of the bearing conditions in rotating machinery, a system for journal bearing diagnosis by AE was developed. Acoustic emission technique is used to detect abnormal conditions in the bearing system. And various data such as AE events, rms voltage level of AE signals, and AE parameters were acquired during experiments with the simulated journal bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was accomplished. Bearing diagnosis system is composed of four parts as follows : sensing part for AE sensor and preamplifier, signal processing part for rms-to-dc converting to measure AE rms voltage, interface part for connecting rms signal to PC using A/D converter, graphic display and software part for display of bearing condition and for managing of diagnosis program.

  20. Energy efficiency analysis and implementation of AES on an FPGA

    Science.gov (United States)

    Kenney, David

    The Advanced Encryption Standard (AES) was developed by Joan Daemen and Vincent Rjimen and endorsed by the National Institute of Standards and Technology in 2001. It was designed to replace the aging Data Encryption Standard (DES) and be useful for a wide range of applications with varying throughput, area, power dissipation and energy consumption requirements. Field Programmable Gate Arrays (FPGAs) are flexible and reconfigurable integrated circuits that are useful for many different applications including the implementation of AES. Though they are highly flexible, FPGAs are often less efficient than Application Specific Integrated Circuits (ASICs); they tend to operate slower, take up more space and dissipate more power. There have been many FPGA AES implementations that focus on obtaining high throughput or low area usage, but very little research done in the area of low power or energy efficient FPGA based AES; in fact, it is rare for estimates on power dissipation to be made at all. This thesis presents a methodology to evaluate the energy efficiency of FPGA based AES designs and proposes a novel FPGA AES implementation which is highly flexible and energy efficient. The proposed methodology is implemented as part of a novel scripting tool, the AES Energy Analyzer, which is able to fully characterize the power dissipation and energy efficiency of FPGA based AES designs. Additionally, this thesis introduces a new FPGA power reduction technique called Opportunistic Combinational Operand Gating (OCOG) which is used in the proposed energy efficient implementation. The AES Energy Analyzer was able to estimate the power dissipation and energy efficiency of the proposed AES design during its most commonly performed operations. It was found that the proposed implementation consumes less energy per operation than any previous FPGA based AES implementations that included power estimations. Finally, the use of Opportunistic Combinational Operand Gating on an AES cipher

  1. Improving the throughput of the AES algorithm with multicore processors

    OpenAIRE

    Barnes, A.; Fernando, R.; Mettananda, K.; Ragel, R. G.

    2014-01-01

    AES, Advanced Encryption Standard, can be considered the most widely used modern symmetric key encryption standard. To encrypt/decrypt a file using the AES algorithm, the file must undergo a set of complex computational steps. Therefore a software implementation of AES algorithm would be slow and consume large amount of time to complete. The immense increase of both stored and transferred data in the recent years had made this problem even more daunting when the need to encrypt/decrypt such d...

  2. A intera??o tutor-alunos em EAD: protagonistas de a??es de leitura e escrita

    OpenAIRE

    Soares, Inaldo Firmino

    2010-01-01

    Sob os alicerces da Lingu?stica Aplicada, que vem focalizando as atividades linguageiras a partir de diferentes enfoques te?ricos, este trabalho resulta de uma pesquisa sobre as a??es de linguagem nas intera??es realizadas por alunos e tutores de um curso de Especializa??o em Ensino a Dist?ncia, a partir da plataforma Moodle, e os reflexos dessas a??es no desenvolvimento e aprimoramento da linguagem verbal desses sujeitos. O tema foi abordado ? luz do Interacionismo Sociodis...

  3. Multiple Lookup Table-Based AES Encryption Algorithm Implementation

    Science.gov (United States)

    Gong, Jin; Liu, Wenyi; Zhang, Huixin

    Anew AES (Advanced Encryption Standard) encryption algorithm implementation was proposed in this paper. It is based on five lookup tables, which are generated from S-box(the substitution table in AES). The obvious advantages are reducing the code-size, improving the implementation efficiency, and helping new learners to understand the AES encryption algorithm and GF(28) multiplication which are necessary to correctly implement AES[1]. This method can be applied on processors with word length 32 or above, FPGA and others. And correspondingly we can implement it by VHDL, Verilog, VB and other languages.

  4. Health impacts of mercury cycling in contaminated environments of Central India studied by NAA and ICP-MS

    International Nuclear Information System (INIS)

    Patel, Khageshwar Singh

    2002-01-01

    The environmental and atmospheric samples i.e. surface water, ground water, surface soil, sediment, rain and fog from various sites of contaminated environments of central India were collected in year, 2000-2001. The concentration levels of total-Hg in these samples were analyzed by using techniques i.e. cold vapor- atomic absorption spectrophotometer (CV-AAS), X-ray fluorescence spectrophotometer XFS). Further, the data base of total Hg in the environmental samples would be validated in other laboratories i.e. Prof Dr. Klaus Heumann (Johannes Gutenberg-University, Mainz, Germany), David Amouroux (University of Pau, France) and Dr Joerg Feldmann (University of Aberdeen, Scotland, UK) for exploration of the Hg-contaminated environments by using techniques i.e. ICP-MS/GC, gas chromatography-induced couple atomic emission spectrophotometer (GC-ICP-AES), neutron activation analysis (NAA). (author)

  5. AE8/AP8 Implementations in AE9/AP9, IRBEM, and SPENVIS

    Science.gov (United States)

    2014-02-18

    period applies to orbit generation only; AE8/AP8 utilizes geomagnetic field models from other epochs as specified in the table below.) SHIELDOSE2 model...finite and semi- infinite slab data tables for Bremsstrahlung have been reversed [Heynderickx, private communication, May 2013]. This correction is...Cain, J. C., S. J. Hendricks, R. A. Langel, and W. V. Hudson (1967), A proposed model for the international geomagnetic reference field, 1965, J

  6. Association of glass fragments by their trace elemental content using ICP-MS and LA-ICP-MS in the analysis scheme

    Science.gov (United States)

    Almirall, Jose R.; Montero, Shirly; Furton, Kenneth G.

    2002-08-01

    The importance of glass as evidence of association between a crime event and a suspect has been recognized for some time. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. The physical and chemical properties of glass can be used to differentiate between possible sources and as evidence of association between two fragments of glass thought to originate from the same source. Refractive index (RI) comparisons have been used for this purpose but due to the improved control over glass manufacturing processes, RI values often cannot differentiate glasses, even if the glass originates from different sources. Elemental analysis methods such as NAA, XRF, ICP-AES, and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) have also been used for the comparison of trace elemental compositions and these techniques have been shown to provide an improvement in the discrimination of glass fragments over RI comparisons alone. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The methodology for solution analysis (digestion procedure) and solid sample analysis (laser ablation) of glass is reported and the analytical results are compared. An isotope dilution method is also reported as a high precision technique for elemental analysis of glass fragments. The optimum sampling parameters for laser ablation, for semi-quantitative analysis and element ratio comparisons are also presented. Finally, the results of a case involving the breaking of 15 vehicle windows in an airport parking lot and the association of a suspect to the breakings by the glass fragments found on his person are also presented.

  7. AES, Automated Construction Cost Estimation System

    International Nuclear Information System (INIS)

    Holder, D.A.

    1995-01-01

    A - Description of program or function: AES (Automated Estimating System) enters and updates the detailed cost, schedule, contingency, and escalation information contained in a typical construction or other project cost estimates. It combines this information to calculate both un-escalated and escalated and cash flow values for the project. These costs can be reported at varying levels of detail. AES differs from previous versions in at least the following ways: The schedule is entered at the WBS-Participant, Activity level - multiple activities can be assigned to each WBS-Participant combination; the spending curve is defined at the schedule activity level and a weighing factor is defined which determines percentage of cost for the WBS-Participant applied to the schedule activity; Schedule by days instead of Fiscal Year/Quarter; Sales Tax is applied at the Line Item Level- a sales tax codes is selected to indicate Material, Large Single Item, or Professional Services; a 'data filter' has been added to allow user to define data the report is to be generated for. B - Method of solution: Average Escalation Rate: The average escalation for a Bill of is calculated in three steps. 1. A table of quarterly escalation factors is calculated based on the base fiscal year and quarter of the project entered in the estimate record and the annual escalation rates entered in the Standard Value File. 2. The percentage distribution of costs by quarter for the Bill of Material is calculated based on the schedule entered and the curve type. 3. The percent in each fiscal year and quarter in the distribution is multiplied by the escalation factor for the fiscal year and quarter. The sum of these results is the average escalation rate for that Bill of Material. Schedule by curve: The allocation of costs to specific time periods is dependent on three inputs, starting schedule date, ending schedule date, and the percentage of costs allocated to each quarter. Contingency Analysis: The

  8. Unbelievable security : Matching AES using public key systems

    NARCIS (Netherlands)

    Lenstra, A.K.; Boyd, C.

    2001-01-01

    The Advanced Encryption Standard (AES) provides three levels of security: 128, 192, and 256 bits. Given a desired level of security for the AES, this paper discusses matching public key sizes for RSA and the ElGamal family of protocols. For the latter both traditional multiplicative groups of finite

  9. Study on water-sediment interaction in samples from Rio das Velhas - Minas Gerais State - Brazil using instrumental neutron activation analysis, and argon plasma coupled mass spectroscopy; Estudo da interacao agua-sedimento em amostras do Rio das Velhas - MG utilizando os metodos: analise por ativacao neutronica instrumental (INAA) e espectrometria de massa acoplada a um plasma de argonio (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Veado, Maria Adelaide R.V.; Oliveira, Arno H. de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Revel, G.; Pinte, G. [CEA Centre d`Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Lab. d`Analyse par Activation Pierre Sue; Toulhoat, P. [CEA Centre d`Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Unite Mixte de Recherche Analyse et Environnement

    1999-11-01

    Sorption of the metallic elements in aqueous solutions in surface of the hydroxides affects the transport of heavy elements in the freshwaters. Sorption and the chemistry of the hydroxides are important studies for knowledge in geology, waters and waste treatment, and environment studies. In the industrial mining region areas, the river surface waters are subject to modifications in its physical and chemistries properties: pH, DBO, conductivity and alkalinity. Instrumental neutron activation analysis and inductively coupled plasma-mass spectrometry (ICP-MS), have ben used for the determination of toxic heavy metals and others pollutants in the Das Velhas river in State of Minas Gerais, in south-east Brazil. Water samples were collected with acidification on site, which provoked a change of its natural pH. Consequently, metallic elements associated to hydroxides and to particles in suspension were liberated. The objective of this paper is to show the different behavior of any elements, in water of Das Velhas river, with relation of its chemical forms (cations or anions), the solubility degree, the pH and the presence of rare earth elements. (author) 11 refs., 10 figs.; e-mail: adelaide at nuclear.ufmg.br; heeren at nuclear.ufmg.br; grevel at drecam.cea.fr; pierre.toulhoat at cea.fr

  10. Test and Verification of AES Used for Image Encryption

    Science.gov (United States)

    Zhang, Yong

    2018-03-01

    In this paper, an image encryption program based on AES in cipher block chaining mode was designed with C language. The encryption/decryption speed and security performance of AES based image cryptosystem were tested and used to compare the proposed cryptosystem with some existing image cryptosystems based on chaos. Simulation results show that AES can apply to image encryption, which refutes the widely accepted point of view that AES is not suitable for image encryption. This paper also suggests taking the speed of AES based image encryption as the speed benchmark of image encryption algorithms. And those image encryption algorithms whose speeds are lower than the benchmark should be discarded in practical communications.

  11. The global compendium of Aedes aegypti and Ae. albopictus occurrence

    Science.gov (United States)

    Kraemer, Moritz U. G.; Sinka, Marianne E.; Duda, Kirsten A.; Mylne, Adrian; Shearer, Freya M.; Brady, Oliver J.; Messina, Jane P.; Barker, Christopher M.; Moore, Chester G.; Carvalho, Roberta G.; Coelho, Giovanini E.; van Bortel, Wim; Hendrickx, Guy; Schaffner, Francis; Wint, G. R. William; Elyazar, Iqbal R. F.; Teng, Hwa-Jen; Hay, Simon I.

    2015-07-01

    Aedes aegypti and Ae. albopictus are the main vectors transmitting dengue and chikungunya viruses. Despite being pathogens of global public health importance, knowledge of their vectors’ global distribution remains patchy and sparse. A global geographic database of known occurrences of Ae. aegypti and Ae. albopictus between 1960 and 2014 was compiled. Herein we present the database, which comprises occurrence data linked to point or polygon locations, derived from peer-reviewed literature and unpublished studies including national entomological surveys and expert networks. We describe all data collection processes, as well as geo-positioning methods, database management and quality-control procedures. This is the first comprehensive global database of Ae. aegypti and Ae. albopictus occurrence, consisting of 19,930 and 22,137 geo-positioned occurrence records respectively. Both datasets can be used for a variety of mapping and spatial analyses of the vectors and, by inference, the diseases they transmit.

  12. AE/flaw characterization for nuclear pressure vessels

    International Nuclear Information System (INIS)

    Hutton, P.H.; Kurtz, R.J.; Pappas, R.A.

    1984-01-01

    This chapter discusses the use of acoustic emission (AE) detected during continuous monitoring to identify and evaluate growing flaws in pressure vessels. Off-reactor testing and on-reactor testing are considered. Relationships for identifying acoustic emission (AE) from crack growth and using the AE data to estimate flaw severity have been developed experimentally by laboratory testing. The purpose of the off-reactor vessel test is to evaluate AE monitoring/interpretation methodology on a heavy section steel vessel under simulated reactor operating conditions. The purpose of on-reactor testing is to evaluate the capability of a monitor system to function in the reactor environment, calibrate the ability to detect AE signals, and to demonstrate that a meaningful criteria can be established to prevent false alarms. An expanded data base is needed from application testing and methodology standardization

  13. Analytical applications of ICP-FTS

    International Nuclear Information System (INIS)

    Faires, L.M.; Palmer, B.A.; Cunningham, P.T.

    1986-01-01

    The Analytical Chemistry Group of the Chemistry Division at Los Alamos National Laboratory has been investigating the analytical utility of the inductively coupled plasma (ICP) - Fourier transform spectrometer (FTS) combination. While a new state-of-the-art FTS facility is under construction at Los Alamos, preliminary data has been obtained on the one-meter FTS at the National Solar Observatory at Kitt Peak, Arizona. This paper presents an update of the Los Alamos FTS facility, which is expected to be completed in 1986, and presents data showing the analytical potential of an ICP-FTS system. Some of the potential problems of the multiplex disadvantage are discussed, and the advantages of the high resolution obtainable with the FTS are illustrated

  14. Reconfigurable Secure Video Codec Based on DWT and AES Processor

    Directory of Open Access Journals (Sweden)

    Rached Tourki

    2010-01-01

    Full Text Available In this paper, we proposed a secure video codec based on the discrete wavelet transformation (DWT and the Advanced Encryption Standard (AES processor. Either, use of video coding with DWT or encryption using AES is well known. However, linking these two designs to achieve secure video coding is leading. The contributions of our work are as follows. First, a new method for image and video compression is proposed. This codec is a synthesis of JPEG and JPEG2000,which is implemented using Huffman coding to the JPEG and DWT to the JPEG2000. Furthermore, an improved motion estimation algorithm is proposed. Second, the encryptiondecryption effects are achieved by the AES processor. AES is aim to encrypt group of LL bands. The prominent feature of this method is an encryption of LL bands by AES-128 (128-bit keys, or AES-192 (192-bit keys, or AES-256 (256-bit keys.Third, we focus on a method that implements partial encryption of LL bands. Our approach provides considerable levels of security (key size, partial encryption, mode encryption, and has very limited adverse impact on the compression efficiency. The proposed codec can provide up to 9 cipher schemes within a reasonable software cost. Latency, correlation, PSNR and compression rate results are analyzed and shown.

  15. Characterization of Aes nuclear foci in colorectal cancer cells

    Science.gov (United States)

    Itatani, Yoshiro; Sonoshita, Masahiro; Kakizaki, Fumihiko; Okawa, Katsuya; Stifani, Stefano; Itoh, Hideaki; Sakai, Yoshiharu; Taketo, M. Mark

    2016-01-01

    Amino-terminal enhancer of split (Aes) is a member of Groucho/Transducin-like enhancer (TLE) family. Aes is a recently found metastasis suppressor of colorectal cancer (CRC) that inhibits Notch signalling, and forms nuclear foci together with TLE1. Although some Notch-associated proteins are known to form subnuclear bodies, little is known regarding the dynamics or functions of these structures. Here, we show that Aes nuclear foci in CRC observed under an electron microscope are in a rather amorphous structure, lacking surrounding membrane. Investigation of their behaviour during the cell cycle by time-lapse cinematography showed that Aes nuclear foci dissolve during mitosis and reassemble after completion of cytokinesis. We have also found that heat shock cognate 70 (HSC70) is an essential component of Aes foci. Pharmacological inhibition of the HSC70 ATPase activity with VER155008 reduces Aes focus formation. These results provide insight into the understanding of Aes-mediated inhibition of Notch signalling. PMID:26229111

  16. Power efficient and high performance VLSI architecture for AES algorithm

    Directory of Open Access Journals (Sweden)

    K. Kalaiselvi

    2015-09-01

    Full Text Available Advanced encryption standard (AES algorithm has been widely deployed in cryptographic applications. This work proposes a low power and high throughput implementation of AES algorithm using key expansion approach. We minimize the power consumption and critical path delay using the proposed high performance architecture. It supports both encryption and decryption using 256-bit keys with a throughput of 0.06 Gbps. The VHDL language is utilized for simulating the design and an FPGA chip has been used for the hardware implementations. Experimental results reveal that the proposed AES architectures offer superior performance than the existing VLSI architectures in terms of power, throughput and critical path delay.

  17. Spectral lines and coincidence tables for the determination of zirconium, niobium and tantalum with the ICP

    International Nuclear Information System (INIS)

    Wuensch, G.; Wennemer, A.

    1987-01-01

    Coincidence tables for ICP-AES are given for 20 Zr lines, 9 Nb lines and 7 Ta lines. They include 582 interferent lines of 49 elements. The specified interference data (IEC and CCR) hold for a bandwidth FWHM = 16 pm and an interferent concentration of 1,000 mg/l. For trace determinations of Zr, Nb, Ta in a matrix of Fe, Z, Zr, Nb, Ta the dependence of the interference on the matrix concentration is specified up to 10,000 mg/l. Interference data CCR calculated for the ICP from the NBS tables often differ from the measured data by several orders of magnitude. The spectrum of Zr measured at a high concentration shows many weak lines most of which are not even listed in the MIT tables. They give rise to a quasi-continuous background the intensity of which increases nearly linearly with the matrix concentration. Therefore, an increase of sample concentration will not lead to an improved detection limit. The line intensities found in our investigations match well with those listed in the Wohlers tables. (orig.)

  18. Modification of working parameters for routine determination of trace elemental impurities in PuO2 samples by direct current arc-AES

    International Nuclear Information System (INIS)

    Pant, D.K.; Phadke, M.P.; Dapolikar, T.T.; Kapur, H.N.; Kumar, Rajendra; Dubey, K.

    2015-01-01

    In the present work we have altered the parameters of routine method to determine the trace elemental impurities in PuO 2 samples using DC arc source optically coupled with CCD based spectrometer system. The method is basically a fractional distillation technique using DC arc source, involving ignition, dilution of the sample with U 3 O 8 containing carrier mixture, arcing of the sample/standard mixture in DC arc and measurement of analyte signals by spectrometer system. In all fifteen elemental impurities including Boron and Cadmium were determined. Detection limits are comparable with ICP-AES method. (author)

  19. Crack classification in concrete beams using AE parameters

    Science.gov (United States)

    Bahari, N. A. A. S.; Shahidan, S.; Abdullah, S. R.; Ali, N.; Zuki, S. S. Mohd; Ibrahim, M. H. W.; Rahim, M. A.

    2017-11-01

    The acoustic emission (AE) technique is an effective tool for the evaluation of crack growth. The aim of this study is to evaluate crack classification in reinforced concrete beams using statistical analysis. AE has been applied for the early monitoring of reinforced concrete structures using AE parameters such as average frequency, rise time, amplitude counts and duration. This experimental study focuses on the utilisation of this method in evaluating reinforced concrete beams. Beam specimens measuring 150 mm × 250 mm × 1200 mm were tested using a three-point load flexural test using Universal Testing Machines (UTM) together with an AE monitoring system. The results indicated that RA value can be used to determine the relationship between tensile crack and shear movement in reinforced concrete beams.

  20. Pulsational stability of the SX Phe star AE UMa

    Science.gov (United States)

    Pena, J. H.; Renteria, A.; Villarreal, C.; Pina, D. S.; Soni, A. A.; Guillen, J.; Vargas, K.; Trejo, O.

    2016-11-01

    From newly determined times of maxima of the SX Phe star AE UMa and a compilation of previous times of maxima, we were able to determine the nature of this star. With uv photometry we determined its physical parameters.

  1. AE/flaw characterization for nuclear pressure vessels

    International Nuclear Information System (INIS)

    Hutton, P.H.; Kurtz, R.J.; Pappas, R.A.

    1983-10-01

    Significant progress has been shown toward resolving major problems in continuous AE monitoring to detect cracking in reactor pressure boundries. Application is considered an attainable goal. Major needs are an expanded data base from application testiong and methodology standardization

  2. ICP analysis of zinc and zamak alloys

    International Nuclear Information System (INIS)

    Gomez Coedo, A.; Dorado Lopez, M.T.

    1987-01-01

    A study was carried out on the possibilities of inductively coupled plasma emission spectrometry (ICP) in the determination of Cu, Cd, Fe, Pb, Sn, Al and Mg in zinc-base materials using direct sample solutions. A selection of analytical lines is made, on account of both their sensitivity and the corresponding study of spectral interferences; measurable minimum contents and calibrated terms are also established, to conduce therefore to a complete methodology which allows determination of the mentioned elements within the contents established on the specifications of these materials. (author)

  3. Microfabricated hollow microneedle array using ICP etcher

    Science.gov (United States)

    Ji, Jing; Tay, Francis E. H.; Miao, Jianmin

    2006-04-01

    This paper presents a developed process for fabrication of hollow silicon microneedle arrays. The inner hollow hole and the fluidic reservoir are fabricated in deep reactive ion etching. The profile of outside needles is achieved by the developed fabrication process, which combined isotropic etching and anisotropic etching with inductively coupled plasma (ICP) etcher. Using the combination of SF6/O2 isotropic etching chemistry and Bosch process, the high aspect ratio 3D and high density microneedle arrays are fabricated. The generated needle external geometry can be controlled by etching variables in the isotropic and anisotropic cases.

  4. Microfabricated hollow microneedle array using ICP etcher

    International Nuclear Information System (INIS)

    Ji Jing; Tay, Francis E H; Miao Jianmin

    2006-01-01

    This paper presents a developed process for fabrication of hollow silicon microneedle arrays. The inner hollow hole and the fluidic reservoir are fabricated in deep reactive ion etching. The profile of outside needles is achieved by the developed fabrication process, which combined isotropic etching and anisotropic etching with inductively coupled plasma (ICP) etcher. Using the combination of SF 6 /O 2 isotropic etching chemistry and Bosch process, the high aspect ratio 3D and high density microneedle arrays are fabricated. The generated needle external geometry can be controlled by etching variables in the isotropic and anisotropic cases

  5. Microfabricated hollow microneedle array using ICP etcher

    Energy Technology Data Exchange (ETDEWEB)

    Ji Jing [Mechanical Engineering National University of Singapore, 119260, Singapore (Singapore); Tay, Francis E H [Mechanical Engineering National University of Singapore, 119260, Singapore (Singapore); Miao Jianmin [MicroMachines Center, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore)

    2006-04-01

    This paper presents a developed process for fabrication of hollow silicon microneedle arrays. The inner hollow hole and the fluidic reservoir are fabricated in deep reactive ion etching. The profile of outside needles is achieved by the developed fabrication process, which combined isotropic etching and anisotropic etching with inductively coupled plasma (ICP) etcher. Using the combination of SF{sub 6}/O{sub 2} isotropic etching chemistry and Bosch process, the high aspect ratio 3D and high density microneedle arrays are fabricated. The generated needle external geometry can be controlled by etching variables in the isotropic and anisotropic cases.

  6. Reconfigurable Secure Video Codec Based on DWT and AES Processor

    OpenAIRE

    Rached Tourki; M. Machhout; B. Bouallegue; M. Atri; M. Zeghid; D. Dia

    2010-01-01

    In this paper, we proposed a secure video codec based on the discrete wavelet transformation (DWT) and the Advanced Encryption Standard (AES) processor. Either, use of video coding with DWT or encryption using AES is well known. However, linking these two designs to achieve secure video coding is leading. The contributions of our work are as follows. First, a new method for image and video compression is proposed. This codec is a synthesis of JPEG and JPEG2000,which is implemented using Huffm...

  7. Implementasi Algoritma Kriptografi Aes Pada Mikrokontroler Atmega32

    OpenAIRE

    Seniman

    2011-01-01

    The purpose of this study is to develop a microcomputer or microcontroller system which has a feature to encrypt data with AES algorithm. The input comes from keystrokes of keyboard and the result of the encryption process is stored in the microcontroller's EEPROM. The system is developed using the C programming languange with WinAVR interface. The research method being used to develop the system are data library collection such as the hardware datasheet, the specification of AES algorithm an...

  8. ICP curve morphology and intracranial flow-volume changes

    DEFF Research Database (Denmark)

    Unnerbäck, Mårten; Ottesen, Johnny T.; Reinstrup, Peter

    2018-01-01

    proposed to shape the ICP curve. This study tested the hypothesis that the ICP curve correlates to intracranial volume changes. METHODS: Cine phase contrast magnetic resonance imaging (MRI) examinations were performed in neuro-intensive care patients with simultaneous ICP monitoring. The MRI was set......BACKGROUND: The intracranial pressure (ICP) curve with its different peaks has been extensively studied, but the exact physiological mechanisms behind its morphology are still not fully understood. Both intracranial volume change (ΔICV) and transmission of the arterial blood pressure have been...

  9. New application and future of ICP-MS

    International Nuclear Information System (INIS)

    Masuda, Kimihiko

    1994-01-01

    By ICP-MS, since high sensibility, multi-element rapid analysis and isotope ratio analysis can be carried out, the position as the analysis for ultra-minute amount of elements has been established. Further recently, sample feeder system has been developed, and the multi-collector type device for the purpose of high resolution type isotope ratio analysis has appeared, so the range of its application is spreading more and more. In this report, the examples of application which were able to be attained accompanying the development of these devices are introduced, and the development of the ICP-MS hereafter is described. At present, about 1000 apparatuses are in operation in the world, and the application spread to the fields of semiconductors and materials, earth science, environment, atomic energy and so on. The ICP-MS was developed for the purpose of easily carrying out spectral analysis with high sensibility by using argon ICP as the ion source and doing ion detection which is more efficient than light detection, and has lower background. The progress and the present status of the ICP-MS are reported. As the latest examples of application of the ICP-MS, the analysis of iron by quadrupole type ICP-MS, the small region measurement of solids by laser abrasion, ultra-minute amount analysis by high resolution ICP-MS, the isotope ratio measurement of lead by multi-collector type ICP-MS are reported. (K.I.)

  10. Changes in histopathology and cytokeratin AE1/AE3 expression in skin graft with different time on Indonesian local cats.

    Science.gov (United States)

    Erwin; Etriwati; Gunanti; Handharyani, Ekowati; Noviana, Deni

    2017-06-01

    A good skin graft histopathology is followed by formation of hair follicle, sweat gland, sebaceous gland, blood vessel, lightly dense connective tissue, epidermis, and dermis layer. This research aimed to observe histopathology feature and cytokeratin AE1/AE3 expression on cat skin post skin grafting within a different period of time. Nine male Indonesian local cats aged 1-2 years old weighing 3-4 kg were separated into three groups. First surgery created defect wound of 2 cm × 2 cm in size to whole groups. The wounds were left alone for several days, differing in interval between each group, respectively: Group I (for 2 days), Group II (for 4 days), and Group III (for 6 days). The second surgery was done to each group which harvested skin of thoracic area and applied it on recipient wound bed. On day 24 th post skin graft was an examination of histopathology and cytokeratin AE1/AE3 immunohistochemistry. Group I donor skin's epidermis layer had not formed completely whereas epidermis of donor skin of Groups II and III had completely formed. In all group hair follicle, sweat gland, sebaceous gland, and neovascularization were found. The density of connective tissue in Group I was very solid than other groups. Cytokeratin AE1/AE3 expression was found on donor skin's epithelial cell in epidermis and dermis layer with very brown intensity for Group II, brown intensity for Group II, and lightly brown for Group I. Histopathological structure and cytokeratin AE1/AE3 expression post skin graft are better in Groups II and III compared to Group I.

  11. Determination of actinides using ICP-SFMS

    International Nuclear Information System (INIS)

    Nygren, Ulrika

    2006-01-01

    Interest in the determination of the actinides using ICP-MS has steadily increased with the development of systems capable of more sensitive and precise measurements. However, the analysis of less abundant actinides such as Pu and Am is not straightforward due to the need for chemical separation of these elements prior to determination. In many applications of mass-spectrometric actinide analysis, isotope ratio measurements are important, either for the analysis of the isotopic composition of, e.g., U or Pu in the sample, or for quantitative determinations using isotope dilution mass spectrometry. In order to achieve high precision and accuracy in an isotope ratio measurement, corrections for instrumentally induced systematic errors, e.g., due to dead-time and mass bias, need to be considered. In this thesis, different aspects of actinide analysis using ICP-SFMS have been addressed. In Papers I and III, separation procedures based on solid phase extraction for Pu, Am and U were developed and evaluated with respect to chemical yield and separation from elements causing spectral interferences. Applications of the analytical procedures developed comprised measurement of the 240 Pu/ 2 3 9Pu ratio in environmental reference materials, and age determination of Pu based on the 241 Pu/ 241 Am and 240 Pu/ 236 U ratios. In the application of different separation procedures for Pu, previously unidentified spectral interferences were discovered. In Paper II, these interferences were identified as lanthanide phosphate ions and the composition and formation of these species with respect to different instrumental parameters were further examined. Due to the importance of precise and accurate isotope ratio determination, a thorough investigation of the instrumental dead time of an ICP-SFMS system was performed. The dead time was evaluated via both isotope ratio and electronic measurements of the output from the detector amplifier. It was found that the overall uncertainty in ratio

  12. Integrated care pathways for airway diseases (AIRWAYS-ICPs)

    NARCIS (Netherlands)

    Bousquet, J.; Addis, A.; Adcock, I.; Agache, I.; Agusti, A.; Alonso, A.; Annesi-Maesano, I.; Anto, J. M.; Bachert, C.; Baena-Cagnani, C. E.; Bai, C.; Baigenzhin, A.; Barbara, C.; Barnes, P. J.; Bateman, E. D.; Beck, L.; Bedbrook, A.; Bel, E. H.; Benezet, O.; Bennoor, K. S.; Benson, M.; Bernabeu-Wittel, M.; Bewick, M.; Bindslev-Jensen, C.; Blain, H.; Blasi, F.; Bonini, M.; Bonini, S.; Boulet, L. P.; Bourdin, A.; Bourret, R.; Bousquet, P. J.; Brightling, C. E.; Briggs, A.; Brozek, J.; Buhl, R.; Bush, A.; Caimmi, D.; Calderon, M.; Calverley, P.; Camargos, P. A.; Camuzat, T.; Canonica, G. W.; Carlsen, K. H.; Casale, T. B.; Cazzola, M.; Cepeda Sarabia, A. M.; Cesario, A.; Chen, Y. Z.; Chkhartishvili, E.; Chavannes, N. H.; Chiron, R.; Chuchalin, A.; Chung, K. F.; Cox, L.; Crooks, G.; Crooks, M. G.; Cruz, A. A.; Custovic, A.; Dahl, R.; Dahlen, S. E.; de Blay, F.; Dedeu, T.; Deleanu, D.; Demoly, P.; Devillier, P.; Didier, A.; Dinh-Xuan, A. T.; Djukanovic, R.; Dokic, D.; Douagui, H.; Dubakiene, R.; Eglin, S.; Elliot, F.; Emuzyte, R.; Fabbri, L.; Fink Wagner, A.; Fletcher, M.; Fokkens, W. J.; Fonseca, J.; Franco, A.; Frith, P.; Furber, A.; Gaga, M.; Garcés, J.; Garcia-Aymerich, J.; Gamkrelidze, A.; Gonzales-Diaz, S.; Gouzi, F.; Guzmán, M. A.; Haahtela, T.; Harrison, D.; Hayot, M.; Heaney, L. G.; Heinrich, J.; Hellings, P. W.; Hooper, J.; Humbert, M.; Hyland, M.; Iaccarino, G.; Jakovenko, D.; Jardim, J. R.; Jeandel, C.; Jenkins, C.; Johnston, S. L.; Jonquet, O.; Joos, G.; Jung, K. S.; Kalayci, O.; Karunanithi, S.; Keil, T.; Khaltaev, N.; Kolek, V.; Kowalski, M. L.; Kull, I.; Kuna, P.; Kvedariene, V.; Le, L. T.; Lodrup Carlsen, K. C.; Louis, R.; MacNee, W.; Mair, A.; Majer, I.; Manning, P.; de Manuel Keenoy, E.; Masjedi, M. R.; Melen, E.; Melo-Gomes, E.; Menzies-Gow, A.; Mercier, G.; Mercier, J.; Michel, J. P.; Miculinic, N.; Mihaltan, F.; Milenkovic, B.; Molimard, M.; Momas, I.; Montilla-Santana, A.; Morais-Almeida, M.; Morgan, M.; N'Diaye, M.; Nafti, S.; Nekam, K.; Neou, A.; Nicod, L.; O'Hehir, R.; Ohta, K.; Paggiaro, P.; Palkonen, S.; Palmer, S.; Papadopoulos, N. G.; Papi, A.; Passalacqua, G.; Pavord, I.; Pigearias, B.; Plavec, D.; Postma, D. S.; Price, D.; Rabe, K. F.; Radier Pontal, F.; Redon, J.; Rennard, S.; Roberts, J.; Robine, J. M.; Roca, J.; Roche, N.; Rodenas, F.; Roggeri, A.; Rolland, C.; Rosado-Pinto, J.; Ryan, D.; Samolinski, B.; Sanchez-Borges, M.; Schünemann, H. J.; Sheikh, A.; Shields, M.; Siafakas, N.; Sibille, Y.; Similowski, T.; Small, I.; Sola-Morales, O.; Sooronbaev, T.; Stelmach, R.; Sterk, P. J.; Stiris, T.; Sud, P.; Tellier, V.; To, T.; Todo-Bom, A.; Triggiani, M.; Valenta, R.; Valero, A. L.; Valiulis, A.; Valovirta, E.; van Ganse, E.; Vandenplas, O.; Vasankari, T.; Vestbo, J.; Vezzani, G.; Viegi, G.; Visier, L.; Vogelmeier, C.; Vontetsianos, T.; Wagstaff, R.; Wahn, U.; Wallaert, B.; Whalley, B.; Wickman, M.; Williams, D. M.; Wilson, N.; Yawn, B. P.; Yiallouros, P. K.; Yorgancioglu, A.; Yusuf, O. M.; Zar, H. J.; Zhong, N.; Zidarn, M.; Zuberbier, T.

    2014-01-01

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will

  13. Integrated care pathways for airway diseases (AIRWAYS-ICPs)

    NARCIS (Netherlands)

    Bousquet, J.; Addis, A.; Adcock, I.; Agache, I.; Agusti, A.; Alonso, A.; Annesi-Maesano, I.; Anto, J. M.; Bachert, C.; Baena-Cagnani, C. E.; Bai, C.; Baigenzhin, A.; Barbara, C.; Barnes, P. J.; Bateman, E. D.; Beck, L.; Bedbrook, A.; Bel, E. H.; Benezet, O.; Bennoor, K. S.; Benson, M.; Bernabeu-Wittel, M.; Bewick, M.; Bindslev-Jensen, C.; Blain, H.; Blasi, F.; Bonini, M.; Bonini, S.; Boulet, L. P.; Bourdin, A.; Bourret, R.; Bousquet, P. J.; Brightling, C. E.; Briggs, A.; Brozek, J.; Buh, R.; Bush, A.; Caimmi, D.; Calderon, M.; Calverley, P.; Camargos, P. A.; Camuzat, T.; Canonica, G. W.; Carlsen, K. H.; Casale, T. B.; Cazzola, M.; Sarabia, A. M. Cepeda; Cesario, A.; Chen, Y. Z.; Chkhartishvili, E.; Chavannes, N. H.; Chiron, R.; Chuchalin, A.; Chung, K. F.; Cox, L.; Crooks, G.; Crooks, M. G.; Cruz, A. A.; Custovic, A.; Dahl, R.; Dahlen, S. E.; De Blay, F.; Dedeu, T.; Deleanu, D.; Demoly, P.; Devillier, P.; Didier, A.; Dinh-Xuan, A. T.; Djukanovic, R.; Dokic, D.; Douagui, H.; Dubakiene, R.; Eglin, S.; Elliot, F.; Emuzyte, R.; Fabbri, L.; Wagner, A. Fink; Fletcher, M.; Fokkens, W. J.; Fonseca, J.; Franco, A.; Frith, P.; Furber, A.; Gaga, M.; Garces, J.; Garcia-Aymerich, J.; Gamkrelidze, A.; Gonzales-Diaz, S.; Gouzi, F.; Guzman, M. A.; Haahtela, T.; Harrison, D.; Hayot, M.; Heaney, L. G.; Heinrich, J.; Hellings, P. W.; Hooper, J.; Humbert, M.; Hyland, M.; Iaccarino, G.; Jakovenko, D.; Jardim, J. R.; Jeandel, C.; Jenkins, C.; Johnston, S. L.; Jonquet, O.; Joos, G.; Jung, K. S.; Kalayci, O.; Karunanithi, S.; Keil, T.; Khaltaev, N.; Kolek, V.; Kowalski, M. L.; Kull, I.; Kuna, P.; Kvedariene, V.; Le, L. T.; Carlsen, K. C. Lodrup; Louis, R.; MacNee, W.; Mair, A.; Majer, I.; Manning, P.; Keenoy, E. de Manuel; Masjedi, M. R.; Meten, E.; Melo-Gomes, E.; Menzies-Gow, A.; Mercier, G.; Mercier, J.; Michel, J. P.; Miculinic, N.; Mihaltan, F.; Milenkovic, B.; Molimard, M.; Mamas, I.; Montilla-Santana, A.; Morais-Almeida, M.; Morgan, M.; N'Diaye, M.; Nafti, S.; Nekam, K.; Neou, A.; Nicod, L.; O'Hehir, R.; Ohta, K.; Paggiaro, P.; Palkonen, S.; Palmer, S.; Papadopoulos, N. G.; Papi, A.; Passalacqua, G.; Pavord, I.; Pigearias, B.; Plavec, D.; Postma, D. S.; Price, D.; Rabe, K. F.; Pontal, F. Radier; Redon, J.; Rennard, S.; Roberts, J.; Robine, J. M.; Roca, J.; Roche, N.; Rodenas, F.; Roggeri, A.; Rolland, C.; Rosado-Pinto, J.; Ryan, D.; Samolinski, B.; Sanchez-Borges, M.; Schunemann, H. J.; Sheikh, A.; Shields, M.; Siafakas, N.; Sibille, Y.; Similowski, T.; Small, I.; Sola-Morales, O.; Sooronbaev, T.; Stelmach, R.; Sterk, P. J.; Stiris, T.; Sud, P.; Tellier, V.; To, T.; Todo-Bom, A.; Triggiani, M.; Valenta, R.; Valero, A. L.; Valiulis, A.; Valovirta, E.; Van Ganse, E.; Vandenplas, O.; Vasankari, T.; Vestbo, J.; Vezzani, G.; Viegi, G.; Visier, L.; Vogelmeier, C.; Vontetsianos, T.; Wagstaff, R.; Wahn, U.; Wallaert, B.; Whalley, B.; Wickman, M.; Williams, D. M.; Wilson, N.; Yawn, B. P.; Yiallouros, P. K.; Yorgancioglu, A.; Yusuf, O. M.; Zar, H. J.; Zhong, N.; Zidarn, M.; Zuberbier, T.

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will

  14. Impacto ambiental por metales pesados en suelos y plantas del entorno de un depósito de chatarra procedente de automóviles de desguace

    Directory of Open Access Journals (Sweden)

    Chicharro, A.

    1998-05-01

    Full Text Available The contaminant impact of cadmium, chromium, copper, nickel, lead and zinc on soils and vegetation in the surroundings of a scrapyard of discarded vehicles, taken at several distances of the contaminant source, is evaluated and compared with control samples free of contamination. The total metal contents of these elements in the soils and vegetation samples are determined by ICP-AES and their presence in soils is detected by particles analysis with SEM-EDXRA. The contents of the affected soils are remarkably higher than the ones of a control sample for the all elements and gradually decrease from the contaminant source. These contents in plants are also relevantly higher than the values of the control sample, and are especially high for the aereal parts. This remarkable contamination, moreover the great retention capacity of these soils, due to their edaphical characteristics, and the presence of a great quantity of not-mineral particles, may indicate that the probable access path of the metal contaminants to the plants could be the atmospherical dispersion of the particles generated by the scrapyard activities (burning and transformation of the vehicles scrap.

    Se evalúa el impacto contaminante de cadmio, cromo, cobre, níquel, plomo y cinc en suelos y vegetación del entorno de un depósito de chatarra de automóviles, a diferentes distancias del mismo, tomando como referencia muestras control no contaminadas. Los contenidos totales de dichos elementos en muestras de suelos y plantas se determinan mediante ICP-AES, y su presencia en suelos mediante análisis de partículas por SEM-EDXRA. En los suelos, se detectan contenidos muy superiores a los de una muestra control para todos los elementos, que decrecen de forma gradual desde el foco contaminante. Estos contenidos en las plantas también son muy superiores a los valores de la muestra control, siendo especialmente elevados en las partes aéreas. Esta alta contaminación de las partes

  15. Soil analyses by ICP-MS (Review)

    International Nuclear Information System (INIS)

    Yamasaki, Shin-ichi

    2000-01-01

    Soil analyses by inductively coupled plasma mass spectrometry (ICP-MS) are reviewed. The first half of the paper is devoted to the development of techniques applicable to soil analyses, where diverse analytical parameters are carefully evaluated. However, the choice of soil samples is somewhat arbitrary, and only a limited number of samples (mostly reference materials) are examined. In the second half, efforts are mostly concentrated on the introduction of reports, where a large number of samples and/or very precious samples have been analyzed. Although the analytical techniques used in these reports are not necessarily novel, valuable information concerning such topics as background levels of elements in soils, chemical forms of elements in soils and behavior of elements in soil ecosystems and the environment can be obtained. The major topics discussed are total elemental analysis, analysis of radionuclides with long half-lives, speciation, leaching techniques, and isotope ratio measurements. (author)

  16. Ophthalmodynamometry for ICP prediction and pilot test on Mt. Everest.

    Science.gov (United States)

    Querfurth, Henry W; Lieberman, Philip; Arms, Steve; Mundell, Steve; Bennett, Michael; van Horne, Craig

    2010-11-01

    A recent development in non-invasive techniques to predict intracranial pressure (ICP) termed venous ophthalmodynamometry (vODM) has made measurements in absolute units possible. However, there has been little progress to show utility in the clinic or field. One important application would be to predict changes in actual ICP during adaptive responses to physiologic stress such as hypoxia. A causal relationship between raised intracranial pressure and acute mountain sickness (AMS) is suspected. Several MRI studies report that modest physiologic increases in cerebral volume, from swelling, normally accompany subacute ascent to simulated high altitudes. 1) Validate and calibrate an advanced, portable vODM instrument on intensive patients with raised intracranial pressure and 2) make pilot, non-invasive ICP estimations of normal subjects at increasing altitudes. The vODM was calibrated against actual ICP in 12 neurosurgical patients, most affected with acute hydrocephalus and monitored using ventriculostomy/pressure transducers. The operator was blinded to the transducer read-out. A clinical field test was then conducted on a variable data set of 42 volunteer trekkers and climbers scaling Mt. Everest, Nepal. Mean ICPs were estimated at several altitudes on the ascent both across and within subjects. Portable vODM measurements increased directly and linearly with ICP resulting in good predictability (r = 0.85). We also found that estimated ICP increases normally with altitude (10 ± 3 mm Hg; sea level to 20 ± 2 mm Hg; 6553 m) and that AMS symptoms did not correlate with raised ICP. vODM technology has potential to reliably estimate absolute ICP and is portable. Physiologic increases in ICP and mild-mod AMS are separate responses to high altitude, possibly reflecting swelling and vasoactive instability, respectively.

  17. Ophthalmodynamometry for ICP prediction and pilot test on Mt. Everest

    Directory of Open Access Journals (Sweden)

    Bennett Michael

    2010-11-01

    Full Text Available Abstract Background A recent development in non-invasive techniques to predict intracranial pressure (ICP termed venous ophthalmodynamometry (vODM has made measurements in absolute units possible. However, there has been little progress to show utility in the clinic or field. One important application would be to predict changes in actual ICP during adaptive responses to physiologic stress such as hypoxia. A causal relationship between raised intracranial pressure and acute mountain sickness (AMS is suspected. Several MRI studies report that modest physiologic increases in cerebral volume, from swelling, normally accompany subacute ascent to simulated high altitudes. Objectives 1 Validate and calibrate an advanced, portable vODM instrument on intensive patients with raised intracranial pressure and 2 make pilot, non-invasive ICP estimations of normal subjects at increasing altitudes. Methods The vODM was calibrated against actual ICP in 12 neurosurgical patients, most affected with acute hydrocephalus and monitored using ventriculostomy/pressure transducers. The operator was blinded to the transducer read-out. A clinical field test was then conducted on a variable data set of 42 volunteer trekkers and climbers scaling Mt. Everest, Nepal. Mean ICPs were estimated at several altitudes on the ascent both across and within subjects. Results Portable vODM measurements increased directly and linearly with ICP resulting in good predictability (r = 0.85. We also found that estimated ICP increases normally with altitude (10 ± 3 mm Hg; sea level to 20 ± 2 mm Hg; 6553 m and that AMS symptoms did not correlate with raised ICP. Conclusion vODM technology has potential to reliably estimate absolute ICP and is portable. Physiologic increases in ICP and mild-mod AMS are separate responses to high altitude, possibly reflecting swelling and vasoactive instability, respectively.

  18. Precise and accurate isotope ratio measurements by ICP-MS.

    Science.gov (United States)

    Becker, J S; Dietze, H J

    2000-09-01

    The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.

  19. On the polarization of Herbig Ae/Be star radiation

    Energy Technology Data Exchange (ETDEWEB)

    Petrova, N I; Shevchenko, V S

    1987-08-01

    Results of multicolor UBVRI polarimetry of 14 Herbig Ae/Be stars including 7 stars for which observations of polarization have been made for the first time are presented. 6 bright Herbig Ae/Be stars (As 441, AS 442, LK H..cap alpha..134, LK H..cap alpha..135, Lk H..cap alpha..169 and V517 Cyg) which belong to star formation region connected with IC 5070 show the polarization from 1 to 4.5. per cent with similar theta (approx. 180 deg) (basically of interstellar nature). The polarimetrical variability of BD+46 deg 3471, BD+65 deg 1637, HD 200775 and Lk H..cap alpha..234 is confirmed. Mechanismes of polarization in Herbig Ae/Be stars in circumstellar formations are discussed.

  20. Accomplishments: AE characterization program for remote flaw evaluation

    International Nuclear Information System (INIS)

    Hutton, P.H.; Schwenk, E.B.; Kurtz, R.J.

    1978-01-01

    The purpose of the program is to develop an experimental/analytical evaluation of the feasibility of detecting and analyzing flaw growth in reactor pressure boundaries by means of continuously monitoring acoustic emission (AE). The investigation is devoted exclusively to ASTM Type A533, Grade B, Class 1 material. The basic approach to interpretive model development is through laboratory testing of 1 to 1 1 / 2 inch (25.4 to 38 mm) thick fracture mechanics specimens in both fatigue and fracture at both room temperature and 550 0 F (288 0 C). Seven parameters are measured for each AE signal and related to fracture mechanics functions. AE data from fracture testing of 6 inch (152 mm) wall pressure vessels are also incorporated in analysis

  1. An Improved Recovery Algorithm for Decayed AES Key Schedule Images

    Science.gov (United States)

    Tsow, Alex

    A practical algorithm that recovers AES key schedules from decayed memory images is presented. Halderman et al. [1] established this recovery capability, dubbed the cold-boot attack, as a serious vulnerability for several widespread software-based encryption packages. Our algorithm recovers AES-128 key schedules tens of millions of times faster than the original proof-of-concept release. In practice, it enables reliable recovery of key schedules at 70% decay, well over twice the decay capacity of previous methods. The algorithm is generalized to AES-256 and is empirically shown to recover 256-bit key schedules that have suffered 65% decay. When solutions are unique, the algorithm efficiently validates this property and outputs the solution for memory images decayed up to 60%.

  2. A high performance hardware implementation image encryption with AES algorithm

    Science.gov (United States)

    Farmani, Ali; Jafari, Mohamad; Miremadi, Seyed Sohrab

    2011-06-01

    This paper describes implementation of a high-speed encryption algorithm with high throughput for encrypting the image. Therefore, we select a highly secured symmetric key encryption algorithm AES(Advanced Encryption Standard), in order to increase the speed and throughput using pipeline technique in four stages, control unit based on logic gates, optimal design of multiplier blocks in mixcolumn phase and simultaneous production keys and rounds. Such procedure makes AES suitable for fast image encryption. Implementation of a 128-bit AES on FPGA of Altra company has been done and the results are as follow: throughput, 6 Gbps in 471MHz. The time of encrypting in tested image with 32*32 size is 1.15ms.

  3. Shaft Crack Identification Based on Vibration and AE Signals

    Directory of Open Access Journals (Sweden)

    Wenxiu Lu

    2011-01-01

    Full Text Available The shaft crack is one of the main serious malfunctions that often occur in rotating machinery. However, it is difficult to locate the crack and determine the depth of the crack. In this paper, the acoustic emission (AE signal and vibration response are used to diagnose the crack. The wavelet transform is applied to AE signal to decompose into a series of time-domain signals, each of which covers a specific octave frequency band. Then an improved union method based on threshold and cross-correlation method is applied to detect the location of the shaft crack. The finite element method is used to build the model of the cracked rotor, and the crack depth is identified by comparing the vibration response of experiment and simulation. The experimental results show that the AE signal is effective and convenient to locate the shaft crack, and the vibration signal is feasible to determine the depth of shaft crack.

  4. Choosing the governing solutions for FA of AES-2006

    International Nuclear Information System (INIS)

    Vasilchenko, I.; Dragunov, Y.; Ryzhov, S.; Kobelev, S.; Vyalitsyn, V.; Troyanov, V.

    2008-01-01

    According to the program approved by the Government of Russia the AES-2006 design intended as a base one for the beginning of realization of the plans on development of the nuclear power engineering of Russia in the near future has been under way now. The most crucial components of the reactor plant are certainly the core and its basic component - FA. In the FA design such factors are concentrated that mainly define safety, profitability, adaptability to manufacture and operation of the fuel and NPP as a whole. As the nearest prototype for AES-2006 the TVS-2M design used at the Balakovo NPP is taken. The report shows on the basis of qualitative and quantitative evaluation that design of TVS-2 and its modifications TVS-2M are in the best compliance with the requirements of the project of the new RP AES-2006. This compliance is confirmed by the operational experience of the basic variant of the design

  5. Comparison of two brain tumor-localizing MRI agent. GD-BOPTA and GD-DTPA. MRI and ICP study of rat brain tumor model

    International Nuclear Information System (INIS)

    Zhang, T.; Matsumura, A.; Yamamoto, T.; Yoshida, F.; Nose, T.

    2000-01-01

    In this study, we compared the behavior of Gd-BOPTA as a brain tumor selective contrast agent with Gd-DTPA in a common dose of 0.1 mmol/kg. We performed a MRI study using those two agent as contrast material, and we measured tissue Gd-concentrations by ICP-AES. As a result, Gd-BOPTA showed a better MRI enhancement in brain tumor. ICP showed significantly greater uptake of Gd-BOPTA in tumor samples, at all time course peaked at 5 minutes after administration, Gd being retained for a longer time in brain tumor till 2 hours, without rapid elimination as Gd-DTPA. We conclude that Gd-BOPTA is a new useful contrast material for MR imaging in brain tumor and an effective absorption agent for neutron capture therapy for further research. (author)

  6. Using ICP and micro-PIXE to investigate possible differences in the mineral composition of genetically modified versus wild-type sorghum grain

    Science.gov (United States)

    Ndimba, R.; Cloete, K.; Mehlo, L.; Kossmann, J.; Mtshali, C.; Pineda-Vargas, C.

    2017-08-01

    In the present study, possible differences in the mineral composition of transgenic versus non-transgenic sorghum grains were investigated using inductively coupled atomic emission spectroscopy (ICP-AES); and, in-tissue elemental mapping by micro Proton-Induced X-ray Emission (micro-PIXE) analysis. ICP AES was used to analyse the bulk mineral content of the wholegrain flour derived from each genotype; whilst micro-PIXE was used to interrogate localised differences in mineral composition specific to certain areas of the grain, such as the bran layer and the central endosperm tissue. According to the results obtained, no significant difference in the average Fe, Zn or Ca content was found to differentiate the transgenic from the wild-type grain using ICP-AES. However, using micro-PIXE, a significant reduction in zinc could be detected in the bran layer of the transgenic grains relative to wild-type. Although it is difficult to draw firm conclusions, as a result of the small sample size used in this study, micro-PIXE has nonetheless proven itself as a useful technique for highlighting the possibility that there may be reduced levels of zinc accumulation in the bran layer of the transgenic grains. Given that the genetic modification targets proteins that are highly concentrated in certain parts of the bran tissue, it seems plausible that the reduced levels of zinc may be an unintended consequence of the silencing of kafirin proteins. Although no immediate health or nutritional concerns emerge from this preliminary finding, it is noted that zinc plays an important biological role within this part of the grain as a structural stabiliser and antioxidant factor. Further study is therefore needed to assess more definitively the extent of the apparent localised reduction in zinc in the transgenic grains and how this may affect other important grain quality characteristics.

  7. Security of the AES with a Secret S-Box

    DEFF Research Database (Denmark)

    Tiessen, Tyge; Knudsen, Lars Ramkilde; Kölbl, Stefan

    2015-01-01

    How does the security of the AES change when the S-box is replaced by a secret S-box, about which the adversary has no knowledge? Would it be safe to reduce the number of encryption rounds? In this paper, we demonstrate attacks based on integral cryptanalysis which allow to recover both the secret...... key and the secret S-box for respectively four, five, and six rounds of the AES. Despite the significantly larger amount of secret information which an adversary needs to recover, the attacks are very efficient with time/data complexities of 217/216, 238/240 and 290/264, respectively. Another...

  8. Summary of detection, location, and characterization capabilities of AE for continuous monitoring of cracks in reactors

    International Nuclear Information System (INIS)

    Hutton, P.H.; Kurtz, R.J.; Friesel, M.A.; Pappas, R.A.; Skorpik, J.R.; Dawson, J.F.

    1984-10-01

    The objective of the program is to develop acoustic emission (AE) methods for continuous monitoring of reactor pressure boundaries to detect and evaluate crack growth. The approach involves three phases: develop relationships to identify crack growth AE signals and to use identified crack growth AE data to estimate flaw severity; evaluate and refine AE/flaw relationships through fatigue testing a heavy section vessel under simulated reactor conditions; and demonstrate continuous AE monitoring on a nuclear power reactor system

  9. LA-ICP-MS of magnetite: Methods and reference materials

    Science.gov (United States)

    Nadoll, P.; Koenig, A.E.

    2011-01-01

    Magnetite (Fe3O4) is a common accessory mineral in many geologic settings. Its variable geochemistry makes it a powerful petrogenetic indicator. Electron microprobe (EMPA) analyses are commonly used to examine major and minor element contents in magnetite. Laser ablation ICP-MS (LA-ICP-MS) is applicable to trace element analyses of magnetite but has not been widely employed to examine compositional variations. We tested the applicability of the NIST SRM 610, the USGS GSE-1G, and the NIST SRM 2782 reference materials (RMs) as external standards and developed a reliable method for LA-ICP-MS analysis of magnetite. LA-ICP-MS analyses were carried out on well characterized magnetite samples with a 193 nm, Excimer, ArF LA system. Although matrix-matched RMs are sometimes important for calibration and normalization of LA-ICP-MS data, we demonstrate that glass RMs can produce accurate results for LA-ICP-MS analyses of magnetite. Cross-comparison between the NIST SRM 610 and USGS GSE-1G indicates good agreement for magnetite minor and trace element data calibrated with either of these RMs. Many elements show a sufficiently good match between the LA-ICP-MS and the EMPA data; for example, Ti and V show a close to linear relationship with correlation coefficients, R2 of 0.79 and 0.85 respectively. ?? 2011 The Royal Society of Chemistry.

  10. Optimization of DIII-D discharges to avoid AE destabilization

    Science.gov (United States)

    Varela, Jacobo; Spong, Donald; Garcia, Luis; Huang, Juan; Murakami, Masanori

    2017-10-01

    The aim of the study is to analyze the stability of Alfven Eigenmodes (AE) perturbed by energetic particles (EP) during DIII-D operation. We identify the optimal NBI operational regimes that avoid or minimize the negative effects of AE on the device performance. We use the reduced MHD equations to describe the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particles, including the effect of the acoustic modes. We add the Landau damping and resonant destabilization effects using a closure relation. We perform parametric studies of the MHD and AE stability, taking into account the experimental profiles of the thermal plasma and EP, also using a range of values of the energetic particles β, density and velocity as well the effect of the toroidal couplings. We reproduce the AE activity observed in high poloidal β discharge at the pedestal and reverse shear discharges. This material based on work is supported both by the U.S. Department of Energy, Office of Science, under Contract DE-AC05-00OR22725 with UT-Battelle, LLC. Research sponsored in part by the Ministerio de Economia y Competitividad of Spain under the project.

  11. Faster and timing-attack resistant AES-GCM

    NARCIS (Netherlands)

    Käsper, E.; Schwabe, P.; Clavier, C.; Gaj, K.

    2009-01-01

    We present a bitsliced implementation of AES encryption in counter mode for 64-bit Intel processors. Running at 7.59 cycles/byte on a Core 2, it is up to 25% faster than previous implementations, while simultaneously offering protection against timing attacks. In particular, it is the only

  12. AES/STEM grain boundary analysis of stabilized zirconia ceramics

    NARCIS (Netherlands)

    Winnubst, Aloysius J.A.; Kroot, P.J.M.; Burggraaf, A.J.

    1983-01-01

    Semiquantitative Auger Electron Spectroscopy (AES) on pure monophasic (ZrO2)0.83(YO1.5)0.17 was used to determine the chemical composition of the grain boundaries. Grain boundary enrichment with Y was observed with an enrichment factor of about 1.5. The difference in activation energy of the ionic

  13. Spectroscopic classification of AT2018aes as a supernova impostor

    Science.gov (United States)

    Andrews, Jennifer; Smith, Nathan; Van Dyk, Schuyler D.

    2018-03-01

    A visual-wavelength optical spectrum of AT2018aes obtained on UT 2018 Mar 13 (JD 2458190.84) with the Magellan Clay telescope (+ LDSS3 spectrograph, VPH-all grism) reveals a narrow H-alpha emission line with a velocity of 525 km/s, with wings extending to roughly +/-1000 km/s.

  14. Enhanced ATM Security using Biometric Authentication and Wavelet Based AES

    Directory of Open Access Journals (Sweden)

    Sreedharan Ajish

    2016-01-01

    Full Text Available The traditional ATM terminal customer recognition systems rely only on bank cards, passwords and such identity verification methods are not perfect and functions are too single. Biometrics-based authentication offers several advantages over other authentication methods, there has been a significant surge in the use of biometrics for user authentication in recent years. This paper presents a highly secured ATM banking system using biometric authentication and wavelet based Advanced Encryption Standard (AES algorithm. Two levels of security are provided in this proposed design. Firstly we consider the security level at the client side by providing biometric authentication scheme along with a password of 4-digit long. Biometric authentication is achieved by considering the fingerprint image of the client. Secondly we ensure a secured communication link between the client machine to the bank server using an optimized energy efficient and wavelet based AES processor. The fingerprint image is the data for encryption process and 4-digit long password is the symmetric key for the encryption process. The performance of ATM machine depends on ultra-high-speed encryption, very low power consumption, and algorithmic integrity. To get a low power consuming and ultra-high speed encryption at the ATM machine, an optimized and wavelet based AES algorithm is proposed. In this system biometric and cryptography techniques are used together for personal identity authentication to improve the security level. The design of the wavelet based AES processor is simulated and the design of the energy efficient AES processor is simulated in Quartus-II software. Simulation results ensure its proper functionality. A comparison among other research works proves its superiority.

  15. Fundamental and applied measurements in ICP MS

    International Nuclear Information System (INIS)

    Carter, Julian Robert

    2002-01-01

    Fundamental and applied aspects of ICP-MS have been investigated to gain an increased understanding of the technique and improve on its analytical capabilities. Dissociation temperatures of polyatomic ions were calculated using a double-focusing sector instrument, to obtain more reliable mass spectral data with controlled vapour introduction via a Dreschel bottle to allow accurate calculation of the ingredients in the plasma. The equilibrium temperature for the plasma, operated at 1280 W calculated using CO + and C 2 + as the thermometric probes, was c.a. 5800 - 7400 K, while using ArO + and ArC + as the thermometric probes the temperature calculated was c.a. 2000 - 7000 K. Calculated dissociation temperatures were used to elucidate the site of formation of these ions. Results confirmed that strongly bound ions such as CO + and C 2 + were formed in the plasma whereas weakly bound ions such as ArO + and ArC + were formed in the interface region due to gross deviation of the calculated temperatures from those expected for a system in thermal equilibrium. The use of helium gas in a hexapole collision cell attenuated the signals of ArH + Ar + , ArO + , ArC + , ArCl + and Ar 2 + allowing improved determination of 39 K + , 40 Ca + , 56 Fe + , 52 Cr + , 75 As + and 80 Se + in standard solutions. The use of the hexapole collision cell also resulted in an enhancement of analyte signals due to the thermalisation of the ion beam. The ion kinetic energy of ions sampled from the plasma and those sampled from the skimmer cone were determined using a modified lens stack to assess the significance for memory effects of material deposited on the skimmer cone. The most probable kinetic energy of Be + ions sampled from the skimmer cone was found to be 2.4 eV, which was considerably lower than the most probable kinetic energy of Be + ions sampled from the plasma, which was found to be 9.5 eV. The low kinetic energy of the ions deposited on the skimmer cone means they will only

  16. Fundamental and applied measurements in ICP MS

    Energy Technology Data Exchange (ETDEWEB)

    Carter, Julian Robert

    2002-07-01

    Fundamental and applied aspects of ICP-MS have been investigated to gain an increased understanding of the technique and improve on its analytical capabilities. Dissociation temperatures of polyatomic ions were calculated using a double-focusing sector instrument, to obtain more reliable mass spectral data with controlled vapour introduction via a Dreschel bottle to allow accurate calculation of the ingredients in the plasma. The equilibrium temperature for the plasma, operated at 1280 W calculated using CO{sup +} and C{sub 2}{sup +} as the thermometric probes, was c.a. 5800 - 7400 K, while using ArO{sup +} and ArC{sup +} as the thermometric probes the temperature calculated was c.a. 2000 - 7000 K. Calculated dissociation temperatures were used to elucidate the site of formation of these ions. Results confirmed that strongly bound ions such as CO{sup +} and C{sub 2}{sup +} were formed in the plasma whereas weakly bound ions such as ArO{sup +} and ArC{sup +} were formed in the interface region due to gross deviation of the calculated temperatures from those expected for a system in thermal equilibrium. The use of helium gas in a hexapole collision cell attenuated the signals of ArH{sup +} Ar{sup +}, ArO{sup +}, ArC{sup +}, ArCl{sup +} and Ar{sub 2}{sup +} allowing improved determination of {sup 39}K{sup +}, {sup 40}Ca{sup +}, {sup 56}Fe{sup +}, {sup 52}Cr{sup +}, {sup 75}As{sup +} and {sup 80}Se{sup +} in standard solutions. The use of the hexapole collision cell also resulted in an enhancement of analyte signals due to the thermalisation of the ion beam. The ion kinetic energy of ions sampled from the plasma and those sampled from the skimmer cone were determined using a modified lens stack to assess the significance for memory effects of material deposited on the skimmer cone. The most probable kinetic energy of Be{sup +} ions sampled from the skimmer cone was found to be 2.4 eV, which was considerably lower than the most probable kinetic energy of Be{sup +} ions

  17. Comparison of a neural network with multiple linear regression for quantitative analysis in ICP-atomic emission spectroscopy

    International Nuclear Information System (INIS)

    Schierle, C.; Otto, M.

    1992-01-01

    A two layer perceptron with backpropagation of error is used for quantitative analysis in ICP-AES. The network was trained by emission spectra of two interfering lines of Cd and As and the concentrations of both elements were subsequently estimated from mixture spectra. The spectra of the Cd and As lines were also used to perform multiple linear regression (MLR) via the calculation of the pseudoinverse S + of the sensitivity matrix S. In the present paper it is shown that there exist close relations between the operation of the perceptron and the MLR procedure. These are most clearly apparent in the correlation between the weights of the backpropagation network and the elements of the pseudoinverse. Using MLR, the confidence intervals over the predictions are exploited to correct for the optical device of the wavelength shift. (orig.)

  18. Practical guide to ICP-MS: a tutorial for beginners

    National Research Council Canada - National Science Library

    Thomas, Robert

    2013-01-01

    ... for those with limited knowledge of the technique. Written by an insider with more than 20 years experience in product development, customer support, and technical marketing for an ICP-MS instrument vendor, the book highlights this powerful ultra...

  19. Inductively coupled plasma mass spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Shimamura, Tadashi

    1997-01-01

    The period of investigation for the previous general remarks on the progress of ICP-MS was from January, 1991 to September, 1993. In the investigation of this time, for the object of the Chemical Abstracts from January, 1994 to September, 1996, retrieval was carried out by using the STN International. As the key words, ICP-MS, Inductively Coupled Plasma Mass Spectrometry or Inductively Coupled Plasma Mass Spectrometer was used. The number of hit was 373 in 1994, 462 in 1995, and 356 as of September, 1996, 1191 in total. The cumulative number of the papers from 1980 to 1996 is shown. It is known how rapidly the ICP-MS has pervaded as the means of analysis. In order to cope with the enormous number of papers, this time, it was decided to do the review by limiting to the papers which were published in the main journals deeply related to analytical chemistry. As to the tendency in the last three years, it is summarized as how to overcome the spectrum interference and matrix effect in the ICP-MS and the trend of using the ICP-MS as the high sensitivity detector for separation techniques. The technical basic research of the ICP-MS on spectrum interference, sample introduction method and others and the analysis of living body samples are reported. (K.I.)

  20. Optical spectrophotometry of oscillations and flickering in AE Aquarii

    Science.gov (United States)

    Welsh, William F.; Horne, Keith; Oke, J. B.

    1993-01-01

    We observed rapid variations in the nova-like cataclysmic variable AE Aquarii for 1.7 hr with 4.3 s time resolution using the 30-channel (3227-10494 A) spectrophotometer on the Hale 5 m telescope. The 16.5 and 33.0 s oscillations show a featureless blue spectrum that can be represented by a blackbody with temperature and area much smaller than the accretion disk. Models consisting of the sum of a K star spectrum and a hydrogen slab in LTE at T = 6000-10,000 K can fit the spectrum of AE Aquarii reasonably well. The spectrum of a flare indicates optically thin gas with T = 8000-12,000 K. The energy released by the flare is large compared to typical stellar flares.

  1. Magnetic fields of Herbig Ae/Be stars

    Directory of Open Access Journals (Sweden)

    Hubrig S.

    2014-01-01

    Full Text Available We report on the status of our spectropolarimetric studies of Herbig Ae/Be stars carried out during the last years. The magnetic field geometries of these stars, investigated with spectropolarimetric time series, can likely be described by centred dipoles with polar magnetic field strengths of several hundred Gauss. A number of Herbig Ae/Be stars with detected magnetic fields have recently been observed with X-shooter in the visible and the near-IR, as well as with the high-resolution near-IR spectrograph CRIRES. These observations are of great importance to understand the relation between the magnetic field topology and the physics of the accretion flow and the accretion disk gas emission.

  2. AE monitoring simplified using digital memory storage and source isolation

    International Nuclear Information System (INIS)

    Hutton, P.H.; Skorpik, J.R.

    1977-01-01

    The general trend in acoustic emission (AE) monitoring systems has been one of increasing complexity. This is particularly true in systems for continuous monitoring which are usually multichannel (perhaps 20 to 40) and incorporate a dedicated minicomputer. A unique concept which reverses this trend for selected applications has been developed at Battelle-Northwest, Richland, WA. This concept uses solid state digital memories to store acquired data in a permanent form which is easily retrieved. It also uses a fundamental method to accept AE data only from a selected area. The digital memory system is designed for short term or long term (months) monitoring. It has been successfully applied in laboratory testing such as fatigue crack growth studies, as well as field monitoring on bridges and piping to detect crack growth. The features of simplicity, versatility, and low cost contribute to expanded practical application of acoustic emission technology

  3. Accelerating Solution Proposal of AES Using a Graphic Processor

    Directory of Open Access Journals (Sweden)

    STRATULAT, M.

    2011-11-01

    Full Text Available The main goal of this work is to analyze the possibility of using a graphic processing unit in non graphical calculations. Graphic Processing Units are being used nowadays not only for game engines and movie encoding/decoding, but also for a vast area of applications, like Cryptography. We used the graphic processing unit as a cryptographic coprocessor in order accelerate AES algorithm. Our implementation of AES is on a GPU using CUDA architecture. The performances obtained show that the CUDA implementation can offer speedups of 11.95Gbps. The tests are conducted in two directions: running the tests on small data sizes that are located in memory and large data that are stored in files on hard drives.

  4. A statistical spectropolarimetric study of Herbig Ae/Be stars

    Science.gov (United States)

    Ababakr, K. M.; Oudmaijer, R. D.; Vink, J. S.

    2017-11-01

    We present H α linear spectropolarimetry of a large sample of Herbig Ae/Be stars. Together with newly obtained data for 17 objects, the sample contains 56 objects, the largest such sample to date. A change in linear polarization across the H α line is detected in 42 (75 per cent) objects, which confirms the previous finding that the circumstellar environment around these stars on small spatial scales has an asymmetric structure, which is typically identified with a disc. A second outcome of this research is that we confirm that Herbig Ae stars are similar to T Tauri stars in displaying a line polarization effect, while depolarization is more common among Herbig Be stars. This finding had been suggested previously to indicate that Herbig Ae stars form in the same manner than T Tauri stars through magnetospheric accretion. It appears that the transition between these two differing polarization line effects occurs around the B7-B8 spectral type. This would in turn not only suggest that Herbig Ae stars accrete in a similar fashion as lower mass stars, but also that this accretion mechanism switches to a different type of accretion for Herbig Be stars. We report that the magnitude of the line effect caused by electron scattering close to the stars does not exceed 2 per cent. Only a very weak correlation is found between the magnitude of the line effect and the spectral type or the strength of the H α line. This indicates that the detection of a line effect only relies on the geometry of the line-forming region and the geometry of the scattering electrons.

  5. ICP measurement accuracy: the effect of temperature drift. Design of a laboratory test for assessment of ICP transducers.

    Science.gov (United States)

    Morgalla, M H; Mettenleiter, H; Katzenberger, T

    1999-01-01

    Intracranial pressure (ICP) monitoring has become the mainstay of multimodal neuromonitoring of comatous patients after head injury. In the presence of rising ICP and faced with pressures, difficult to control, aggressive measures, such as hypothermia may be used. The ICP readings should not be influenced by temperature changes. A laboratory test was designed to simulate temperature variations between 20 degrees C and 45 degrees C at different pressure levels under physiological conditions. Five types of transducers were examined: Epidyn Braun Melsungen, ICT/B-Titan Gaeltec, Camino-OLM-110-4B, Codman MicroSensor ICP-Transducer, Neurovent ICP transducer Rehau Ag+Co. Tests were performed at 6 different pressure levels between 0 mmHg and 50 mmHg. The results show very low drifts of less than 0.15 mmHg degree C-1 for Codman, Epidyn and Neurovent. Gaeltec and Camino exhibited higher drifts of 0.18 mmHg and 0.2 mmHg degree C-1 respectively. Within the temperature range from 35 degrees C to 42 degrees C all probes tested show insignificant temperature drift. Whether these results also apply to other types of transducers needs further evaluation. Problems and requirements related to the design of a laboratory test for the in vitro assessment of ICP transducers are discussed in detail.

  6. Laser ablation ICP-MS for quantitative biomedical applications

    International Nuclear Information System (INIS)

    Konz, Ioana; Fernandez, Beatriz; Fernandez, M.L.; Pereiro, Rosario; Sanz-Medel, Alfredo

    2012-01-01

    LA-ICP-MS allows precise, relatively fast, and spatially resolved measurements of elements and isotope ratios at trace and ultratrace concentration levels with minimal sample preparation. Over the past few years this technique has undergone rapid development, and it has been increasingly applied in many different fields, including biological and medical research. The analysis of essential, toxic, and therapeutic metals, metalloids, and nonmetals in biomedical tissues is a key task in the life sciences today, and LA-ICP-MS has proven to be an excellent complement to the organic MS techniques that are much more commonly employed in the biomedical field. In order to provide an appraisal of the fast progress that is occurring in this field, this review critically describes new developments for LA-ICP-MS as well as the most important applications of LA-ICP-MS, with particular emphasis placed on the quantitative imaging of elements in biological tissues, the analysis of heteroatom-tagged proteins after their separation and purification by gel electrophoresis, and the analysis of proteins that do not naturally have ICP-MS-detectable elements in their structures, thus necessitating the use of labelling strategies. (orig.)

  7. Sodium Bicarbonate for Control of ICP: A Systematic Review.

    Science.gov (United States)

    Zeiler, Frederick A; Sader, Nicholas; West, Michael; Gillman, Lawrence M

    2018-01-01

    Our goal was to perform a systematic review of the literature on the use of intravenous sodium bicarbonate for intracranial pressure (ICP) reduction in patients with neurologic illness. Data sources: articles from MEDLINE, BIOSIS, EMBASE, Global Health, Scopus, Cochrane Library, the International Clinical Trials Registry Platform (inception to April 2015), reference lists of relevant articles, and gray literature were searched. 2 reviewers independently extracted data including population characteristics and treatment characteristics. The strength of evidence was adjudicated using both the Oxford and Grading of Recommendation Assessment Development and Education methodology. Our search strategy produced a total 559 citations. Three original articles were included in the review. There were 2 prospective studies, 1 randomized control trial and 1 single arm, and 1 retrospective case report.Across all studies there were a total of 19 patients studied, with 31 episodes of elevated ICP being treated. Twenty-one of those episodes were treated with sodium bicarbonate infusion, with the remaining 10 treated with hypertonic saline in a control model. All elevated ICP episodes treated with sodium bicarbonate solution demonstrated a significant drop in ICP, without an elevation of serum partial pressure of carbon dioxide. No significant complications were described. There currently exists Oxford level 4, Grading of Recommendation Assessment Development and Education D evidence to support an ICP reduction effect with intravenous sodium bicarbonate in TBI. No comments on its impact in other neuropathologic states, or on patient outcomes, can be made at this time.

  8. Caraterização composicional do AES - um copolímero de enxertia de poli(estireno-co-acrilonitrila em poli(etileno-co-propileno-co-dieno Compositional characterization of AES a graft copolymer based on poly(styrene-co-acrylonitrile and poly(etyhlene-co-propylene-co-diene

    Directory of Open Access Journals (Sweden)

    Renato Turchet

    2006-06-01

    Full Text Available O objetivo deste trabalho é a caracterização do AES, um copolímero de enxertia de poli(estireno-co-acrilonitrila, SAN, em poli(etileno-co-propileno-co-dieno, EPDM. Para tanto, o AES foi submetido à extração seletiva de seus componentes: o SAN livre, o EDPM livre, e o copolímero de enxertia EPDM-g-SAN. O AES e suas frações foram caracterizados por espectroscopia de infravermelho, análise elementar, calorimetria diferencial de varredura e ressonância magnética nuclear, RMN¹H e RMN13C. O AES analisado apresenta a seguinte composição em massa: 65% de EPDM-g-SAN, 13% de EPDM livre e 22% de SAN livre. O EPDM apresenta 69,8% em massa de etileno, 26,5% em massa de propileno e 4,6% em massa do dieno, 2-etilideno-5-norboneno, ENB. O SAN apresenta razão em massa acrilonitrila/estireno de 28/72 e distribuição randômica de comonômeros de estireno e acrilonitrila. Estes resultados são concordantes com a composição do AES fornecida pelo fabricante, indicando que a metodologia proposta é adequada.This work aims the characterization of AES, a graft copolymer based on poly(styrene-co-acrylonitrile, SAN, and poly(etyhlene-co-propylene-co-diene, EPDM. AES was submitted to selective extraction of its components: free SAN, EPDM chains and the graft copolymer EPDM-g-SAN. AES and its fractions were characterized by infrared spectroscopy, elemental analysis, differential scanning calorimetry, 13C and ¹H nuclear magnetic resonance. The AES has 65 wt % of EPDM-g-SAN, 13 wt % of free EPDM and 22 wt % of free SAN. EPDM has 69.8 wt % of ethylene, 26.5 wt % of propylene and 4.6 wt % of diene, 2-ethylidene-5-norbonene ENB. SAN presents acrylonitrile/styrene mass ratio of 28/72 and a random distribution of acrylonitrile and styrene comonomers. These results are in agreement with the composition reported by the AES supplier, indicating that the proposed methodology is adequate.

  9. AE Characteristics affecting the Notch Effect of the Cold Steel SKD11

    Energy Technology Data Exchange (ETDEWEB)

    Han, Eung Kyo; Kim, Ki Choong; Kwon, Dong Ho; Kim, Jae Yeor [Hanyang University, Seoul (Korea, Republic of)

    1986-11-15

    Acoustic Emission is not only expected as a non-destructive evaluation technique in practice but also noted as a new powerful means of evaluation of materials. AE occurs with plastic deformation and propagation of crack, and this patterns of occurrence of AE vary with materials. AE which comes from propagation of crack depends oil the shapes and properties of materials. Like this AE has characteristic of material. The present work is an attempt to evaluate characteristics of carbon steel (SM55C) and Die steel(SKD11) by means of dynamic response of AE method

  10. Quality control of Al alloy by ICP-MS

    International Nuclear Information System (INIS)

    Zahran, N.F.; Amr, M.A.; Helal, A.I.; Waly, S.A.; Afifi, Y.K.

    2000-01-01

    Laser ablation sample introduction system in combination with an inductive coupled plasma mass spectrometer (ICP-MS) is used for the investigation of elemental distribution of Al alloy. The samples are ablated by an ultraviolet laser beam at 266 nm with an energy of 4mJ/shot at a repetition rate of 20 Hz. Samples are digested using HNO 3 in a microwave system and analyzed in a solution form by ICP-MS. The quantification of the analytical results is carried out using multielement solution. Quantitative data from the solution samples are used as a standard data for the laser ablation technique. The effect of Aluminum as a matrix is studied. High-resolution mass spectrometer is used to identify the Aluminum polyatomic ions in the ICP-ion source

  11. Applications of ICP-MS in marine analytical chemistry

    Energy Technology Data Exchange (ETDEWEB)

    McLaren, J W; Siu, K W.M.; Lam, J W; Willie, S N; Maxwell, P S; Palepu, A; Koether, M; Berman, S S [National Research Council of Canada, Ottawa, ON (Canada). Analytical Chemistry Section

    1990-07-01

    The versatility of ICP-MS in marine analytical chemistry is illustrated with applications to the multielement trace analysis of two recently released marine reference materials, the coastal seawater CASS-2 and the non-defatted lobster hepatopancreas tissue LUTS-1, and to the determination of tributyltin and dibutyltin in the harbour sediment reference material PACS-1 by HPLC-ICP-MS. Seawater analyses were performed after separation of the trace elements either by adsorption on immobilized 8-hydroxyquinoline or by reductive coprecipitation with iron and palladium. Simultaneous determination of seven trace elements in LUTS-1, including mercury, by isotope dilution ICP-MS, was achieved after dissolution by microwave digestion with nitric acid and hydrogen peroxide. Butyltin species in PACS-1 were separated by cation exchange HPLC of an extract of the sediment; method detection limits for tributyltin and dibutyltin in sediment samples are estimated to be 5 ng Sn/g and 12 ng Sn/g, respectively. (orig.).

  12. Analysis of nanoparticles using the ICAP Q ICP-MS

    DEFF Research Database (Denmark)

    Kutscher, Daniel; McSheehy-Ducos, Shona; Lindemann, Torsten

    2014-01-01

    The analysis of Nanoparticles (NPs) has become one of the hot topics in analytical chemistry. However, detailed knowledge about potential risks or hazards is still unavailable. Two approaches have been developed in recent years using ICP-MS as a detection system: hyphenation of an appropriate...... separation technique like Field-Flow-Fractionation (FFF), or direct analysis using spICP-MS. The separation of particles and particle mixtures using FFF is based on the differing mobilities of different particle sizes in a laminar liquid flow. FFF is compatible for particle sizes in the low nm to low μm...... range and is thus perfectly suited for the separation of different NPs. Combined with other detection systems such as dynamic light scattering, it can provide also additional information about the particles of interest, like shape. In comparison, spICP-MS is able to analyze NPs directly based...

  13. Air pollution studies using PIXE and ICP methods

    International Nuclear Information System (INIS)

    Stihi, Claudia; Bancuta, Anca; Popescu, I V; Virgolici, M; Cimpoca, V; Gugiu, M; Vlaicu, Gh

    2006-01-01

    In the present work the moss biomonitoring technique and the combination of two analytical techniques - Particle Induced X-ray Emission (PIXE) and Inductively Coupled Plasma (ICP) - were applied for assessing environmental situation from the point of view of air polluting along the transect from north to south of the Dambovita County. PIXE analysis at the Tandem Accelerator FN-8 of the National Institute of Nuclear Physics - Horia Hulubei of Magurele, Bucharest, allowed determination of P, S, Cl, K, Ca, Mn, Fe, Ni, Cu, Zn, As, Sr, Cd and Pb in samples. ICP analyses were made using a Baird ICP2070 - Sequential Plasma Spectrometer in Targoviste and we determined in samples the concentration of Li, B, Na, and Mg together with Cd and Pb. The obtained results will permit to determine the regional extent of heavy metals and toxic elements atmospheric pollution and to identify specially affected areas and local sources of

  14. ICP-MS analysis for long-lived radionuclides

    International Nuclear Information System (INIS)

    Roos, P.

    2010-01-01

    Full text: Inductively coupled plasma mass spectrometry (ICP-MS) is an attractive alternative for the analysis of radioisotopes having a half-life in the order of several hundred years and above. The technique should not be considered a replacement for radiometric measurements of these isotopes but merely an alternative. Similarly to radiometric techniques like alpha and beta spectrometry most analysis of 'low-level' concentrations by ICP-MS requires chemical isolation of the element in question. For 'ultra-low-level' concentrations this clean-up of the sample is usually even more necessary than for the alternative radiometric techniques. The presentation gives an overview of advantages and disadvantages in using ICP-MS and compares it to relevant radiometric alternatives. (author)

  15. Measurement of inclusion size by laser ablation ICP mass spectrometry

    International Nuclear Information System (INIS)

    Karasev, Andrey V.; Suito, Hideaki

    2004-01-01

    By using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), the measurement of particle size has been made for one component oxide (Al 2 O 3 and MgO) and multicomponent oxide (12CaO·7Al 2 O 3 and CaO-Al 2 O 3 -MgO) located on surface of iron or glass sample. The method of particle size estimation by LA-ICP-MS has been developed coupled with a new method of making samples with particles. The size calibration lines for Al 2 O 3 , MgO and CaO particles have been obtained. The results of particle size measurement by LA-ICP-MS are compared with those by SEM and single-particle optical sensing (SPOS) methods. It was confirmed that LA-ICP-MS has the perspective to be used for the quick measurement of inclusion composition and size in metal and other materials. The size frequency distributions of Al 2 O 3 particles measured by LA-ICP-MS in iron samples with particles agree reasonably well with those by SEM and SPOS in the range of particle diameter from 2 to 20 μm. The size of Al 2 O 3 , MgO and complex oxide (12CaO·7Al 2 O 3 and CaO-Al 2 O 3 -MgO) particles measured by LA-ICP-MS is in good agreement with that by SEM in the range of particle diameter from 10 to 40 μm. (author)

  16. Multilevel Analysis of Continuous AE from Helicopter Gearbox

    Czech Academy of Sciences Publication Activity Database

    Chlada, Milan; Převorovský, Zdeněk; Heřmánek, Jan; Krofta, Josef

    2014-01-01

    Roč. 19, č. 12 (2014) ISSN 1435-4934. [European Conference on Non-Destructive Testing (ECNDT 2014) /11./. Praha, 06.10.2014-10.10.2014] R&D Projects: GA MPO FR-TI3/755 Institutional support: RVO:61388998 Keywords : structural health monitoring (SHM) * signal processing * acoustic emission (AE) * diagnostics of helicopter gearbox * wavelet analysis * continuous acoustic emission Subject RIV: JU - Aeronautics, Aerodynamics, Aircrafts http://www.ndt.net/events/ECNDT2014/app/content/Paper/630_Chlada_Rev1.pdf

  17. A New Structural-Differential Property of 5-Round AES

    DEFF Research Database (Denmark)

    Grassi, Lorenzo; Rechberger, Christian; Ronjom, Sondre

    2017-01-01

    AES is probably the most widely studied and used block cipher. Also versions with a reduced number of rounds are used as a building block in many cryptographic schemes, e.g. several candidates of the SHA-3 and CAESAR competition are based on it.So far, non-random properties which are independent ...... a random permutation with only 2 32 chosen texts that has a computational cost of 2(35.6) look-ups into memory of size 2 36 bytes which has a success probability greater than 99%....

  18. "Storms of crustal stress" and AE earthquake precursors

    Directory of Open Access Journals (Sweden)

    G. P. Gregori

    2010-02-01

    Full Text Available Acoustic emission (AE displays violent paroxysms preceding strong earthquakes, observed within some large area (several hundred kilometres wide around the epicentre. We call them "storms of crustal stress" or, briefly "crustal storms". A few case histories are discussed, all dealing with the Italian peninsula, and with the different behaviour shown by the AE records in the Cephalonia island (Greece, which is characterized by a different tectonic setting.

    AE is an effective tool for diagnosing the state of some wide slab of the Earth's crust, and for monitoring its evolution, by means of AE of different frequencies. The same effect ought to be detected being time-delayed, when referring to progressively lower frequencies. This results to be an effective check for validating the physical interpretation.

    Unlike a seismic event, which involves a much limited focal volume and therefore affects a restricted area on the Earth's surface, a "crustal storm" typically involves some large slab of lithosphere and crust. In general, it cannot be easily reckoned to any specific seismic event. An earthquake responds to strictly local rheological features of the crust, which are eventually activated, and become crucial, on the occasion of a "crustal storm". A "crustal storm" lasts typically few years, eventually involving several destructive earthquakes that hit at different times, at different sites, within that given lithospheric slab.

    Concerning the case histories that are here discussed, the lithospheric slab is identified with the Italian peninsula. During 1996–1997 a "crustal storm" was on, maybe elapsing until 2002 (we lack information for the period 1998–2001. Then, a quiet period occurred from 2002 until 26 May 2008, when a new "crustal storm" started, and by the end of 2009 it is still on. During the 1996–1997 "storm" two strong earthquakes occurred (Potenza and

  19. Developing A/E capabilities; areas of special interest

    International Nuclear Information System (INIS)

    Gonzalez, A.; Gurbindo, J.

    1988-01-01

    During the last few years, the methods used by Empresarios Agrupados and INITEC to perform Architect-Engineering work in Spain for nuclear projects has undergone a process of significant change in project management and engineering approaches. Specific practical examples of management techniques and design practices which represent a good record of results will be discussed. They are identified as areas of special interest in developing A/E capabilities for nuclear projects. Command of these areas should produce major payoffs in local participation and contribute to achieving real nuclear engineering capabilities in the country

  20. Power Consumption and Calculation Requirement Analysis of AES for WSN IoT.

    Science.gov (United States)

    Hung, Chung-Wen; Hsu, Wen-Ting

    2018-05-23

    Because of the ubiquity of Internet of Things (IoT) devices, the power consumption and security of IoT systems have become very important issues. Advanced Encryption Standard (AES) is a block cipher algorithm is commonly used in IoT devices. In this paper, the power consumption and cryptographic calculation requirement for different payload lengths and AES encryption types are analyzed. These types include software-based AES-CB, hardware-based AES-ECB (Electronic Codebook Mode), and hardware-based AES-CCM (Counter with CBC-MAC Mode). The calculation requirement and power consumption for these AES encryption types are measured on the Texas Instruments LAUNCHXL-CC1310 platform. The experimental results show that the hardware-based AES performs better than the software-based AES in terms of power consumption and calculation cycle requirements. In addition, in terms of AES mode selection, the AES-CCM-MIC64 mode may be a better choice if the IoT device is considering security, encryption calculation requirement, and low power consumption at the same time. However, if the IoT device is pursuing lower power and the payload length is generally less than 16 bytes, then AES-ECB could be considered.

  1. ICP-MS and elemental tags for the life sciences

    Energy Technology Data Exchange (ETDEWEB)

    Giesen, Charlotte

    2012-08-07

    Inductively coupled plasma mass spectrometry (ICP-MS) has been applied for the analysis of biomolecules due to its high sensitivity, wide linear dynamic range, and multielement capabilities. However, outside the elemental MS community the potential of this technique, e.g. for life sciences applications, is not yet fully exploited. Thus, the development of ICP-MS-based (immuno) assays for a wide range of medical (cancer diagnostics, cisplatin toxicity studies), biochemical (DNA microarray, single cell analysis), and environmental (analysis of comestible goods) applications was accomplished by utilization of chemical labels. Laser ablation (LA)-ICP-MS was employed for the direct analysis of solid samples like microarrays and thin tissue sections. An immunoassay was developed for ochratoxin A (OTA) determination in wine, and ICP-MS detection was compared to conventional photometry by gold nanoparticle tagging and horseradish peroxidase, respectively. Detection limits of the assay were optimized to 0.003 {mu}g L{sup -1}, and the quantification range was 0.01-1 {mu}g L{sup -1} for both methods. For LA-ICP-MS-based DNA microarray detection, gold nanoparticle tags were specifically introduced via a streptavidin-biotin linkage. In immunohistochemistry (IHC), up to 20 tumor markers are routinely evaluated for one patient and thus, a common analysis results in a series of time consuming staining procedures. Hence, LA-ICP-MS was elaborated as a detection tool for a novel, multiplexed IHC analysis of tissue sections. Different lanthanides were employed for the simultaneous detection of up to three tumor markers (Her 2, CK 7, and MUC 1) in a breast cancer tissue. Additionally, iodine was employed as a labeling reagent, and a new LA-ICP-MS method for single cell and cell nucleus imaging was developed at 4 {mu}m laser spot size. Iodine was also applied as a new internal standard for tissue samples. Moreover, Pt-protein complexes separated by an optimized 1D and 2D gel

  2. Genome-Wide Identification and Expression Analysis of the UGlcAE Gene Family in Tomato

    Directory of Open Access Journals (Sweden)

    Xing Ding

    2018-05-01

    Full Text Available The UGlcAE has the capability of interconverting UDP-d-galacturonic acid and UDP-d-glucuronic acid, and UDP-d-galacturonic acid is an activated precursor for the synthesis of pectins in plants. In this study, we identified nine UGlcAE protein-encoding genes in tomato. The nine UGlcAE genes that were distributed on eight chromosomes in tomato, and the corresponding proteins contained one or two trans-membrane domains. The phylogenetic analysis showed that SlUGlcAE genes could be divided into seven groups, designated UGlcAE1 to UGlcAE6, of which the UGlcAE2 were classified into two groups. Expression profile analysis revealed that the SlUGlcAE genes display diverse expression patterns in various tomato tissues. Selective pressure analysis indicated that all of the amino acid sites of SlUGlcAE proteins are undergoing purifying selection. Fifteen stress-, hormone-, and development-related elements were identified in the upstream regions (0.5 kb of these SlUGlcAE genes. Furthermore, we investigated the expression patterns of SlUGlcAE genes in response to three hormones (indole-3-acetic acid (IAA, gibberellin (GA, and salicylic acid (SA. We detected firmness, pectin contents, and expression levels of UGlcAE family genes during the development of tomato fruit. Here, we systematically summarize the general characteristics of the SlUGlcAE genes in tomato, which could provide a basis for further function studies of tomato UGlcAE genes.

  3. Flow sorting of C-genome chromosomes from wild relatives of wheat Aegilops markgrafii, Ae. triuncialis and Ae. cylindrica, and their molecular organization

    Czech Academy of Sciences Publication Activity Database

    Molnár, I.; Vrána, Jan; Farkas, A.; Kubaláková, Marie; Cseh, A.; Molnár-Láng, M.; Doležel, Jaroslav

    2015-01-01

    Roč. 116, č. 2 (2015), s. 189-200 ISSN 0305-7364 R&D Projects: GA MŠk(CZ) LO1204 Institutional support: RVO:61389030 Keywords : Aegilops markgrafii * Ae. triuncialis * Ae. cylindrica Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.982, year: 2015

  4. Determination of rhenium traces in river water by Q-ICP-MS and HR-ICP-MS

    International Nuclear Information System (INIS)

    Uchida, S.; Tagami, K.; Saito, M.

    2003-01-01

    A simple separation method was applied to determine rhenium in river water using Q-ICP-MS and HR-ICP-MS. Re was concentrated from 420-925 ml river water using a TEVA resin minicolumn. Such extraction using a resin could separate Re from most sample matrices and trace elements. Almost 100% recovery was found throughout the method as determined with radioactive multitracers. The HR-ICP-MS was also used for the direct determination because of its low detection limit for Re (0.007 pg/ml). The Re concentration in the river water samples ranged from 0.9 to 6.5 pg/ml and the three analysis results showed good agreement with each other. (author)

  5. Decryption-decompression of AES protected ZIP files on GPUs

    Science.gov (United States)

    Duong, Tan Nhat; Pham, Phong Hong; Nguyen, Duc Huu; Nguyen, Thuy Thanh; Le, Hung Duc

    2011-10-01

    AES is a strong encryption system, so decryption-decompression of AES encrypted ZIP files requires very large computing power and techniques of reducing the password space. This makes implementations of techniques on common computing system not practical. In [1], we reduced the original very large password search space to a much smaller one which surely containing the correct password. Based on reduced set of passwords, in this paper, we parallel decryption, decompression and plain text recognition for encrypted ZIP files by using CUDA computing technology on graphics cards GeForce GTX295 of NVIDIA, to find out the correct password. The experimental results have shown that the speed of decrypting, decompressing, recognizing plain text and finding out the original password increases about from 45 to 180 times (depends on the number of GPUs) compared to sequential execution on the Intel Core 2 Quad Q8400 2.66 GHz. These results have demonstrated the potential applicability of GPUs in this cryptanalysis field.

  6. The spectrum and variability of radio emission from AE Aquarii

    Science.gov (United States)

    Abada-Simon, Meil; Lecacheux, Alain; Bastian, Tim S.; Bookbinder, Jay A.; Dulk, George A.

    1993-01-01

    The first detections of the magnetic cataclysmic variable AE Aquarii at millimeter wavelengths are reported. AE Aqr was detected at wavelengths of 3.4 and 1.25 mm. These data are used to show that the time-averaged spectrum is generally well fitted by a power law S(nu) varies as nu exp alpha, where alpha is approximately equal to 0.35-0.60, and that the power law extends to millimeter wavelengths, i.e., the spectral turnover is at a frequency higher than 240 GHz. It is suggested that the spectrum is consistent with that expected from a superposition of flarelike events where the frequency distribution of the initial flux density is a power law f (S0) varies as S0 exp -epsilon, with index epsilon approximately equal to 1.8. Within the context of this model, the high turnover frequency of the radio spectrum implies magnetic field strengths in excess of 250 G in the source.

  7. Spontaneous wheat-Aegilops biuncialis, Ae. geniculata and Ae. triuncialis amphiploid production, a potential way of gene transference

    OpenAIRE

    Loureiro, I.; Escorial, C.; García-Baudin, J.M.; Chueca, C.

    2009-01-01

    Some F1 hybrid plants between three species of the Aegilops genus and different hexaploid wheat Triticum aestivum cultivars show certain self-fertility, with averages of F1 hybrids bearing F2 seeds of 8.17%, 5.12% and 48.14% for Aegilops biuncialis, Aegilops geniculata and Aegilops triuncialis respectively. In the Ae. triuncialis-wheat combination with ";Astral" wheat cultivar, the fertility was higher than that found in the other combinations. All the F2 seeds studied were spontaneous amphip...

  8. Influence of the operating parameters and of the sample introduction system on time correlation of line intensities using an axially viewed CCD-based ICP-AES system

    Energy Technology Data Exchange (ETDEWEB)

    Grotti, Marco, E-mail: grotti@chimica.unige.i [Dipartimento di Chimica e Chimica Industriale, Via Dodecaneso 31, 16146 Genova (Italy); Todoli, Jose Luis [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, 03080, Alicante (Spain); Mermet, Jean Michel [Spectroscopy Forever, 01390 Tramoyes (France)

    2010-02-15

    The influence of the acquisition and operating parameters on time correlation between emission line intensities was investigated using axially viewed inductively coupled plasma-multichannel-based emission spectrometry and various sample introduction systems. It was found that to obtain flicker-noise limited signals, necessary to compensate for time-correlated signal fluctuations by internal standardization, the flicker-noise magnitude of the sample introduction system, the integration time and the emission line intensity had to be considered. The highest correlation between lines was observed for ultrasonic nebulization with desolvatation, the noisiest system among those considered, for which the contribution of the uncorrelated shot-noise was negligible. In contrast, for sample introduction systems characterized by lower flicker-noise levels, shot-noise led to high, non-correlated RSD values, making the internal standard method to be much less efficient. To minimize shot-noise, time correlation was improved by increasing the emission line intensities and the integration time. Improvement in repeatability did not depend only on time correlation, but also on the ratio between the relative standard deviations of the analytical and reference lines. The best signal compensation was obtained when RSD values of the reference and analytical lines were similar, which is usually obtained when the system is flicker-noise limited, while departure from similarity can lead to a degradation of repeatability when using the internal standard method. Moreover, the use of so-called robust plasma conditions, i.e. a high power (1500 W) along with a low carrier gas flow rate (0.8 L/min) improved also the compensation. Finally, high correlation and consequent improvement in repeatability by internal standardization was observed also in the presence of complex matrices (sediment and soil samples), although a matrix-induced degradation of the correlation between lines was generally observed when using ultrasonic nebulization.

  9. Plants as biomarkers for monitoring heavy metal contaminants on landfill sites using sequential extraction and inductively coupled plasma atomic emission spectrophotometry (ICP-AES).

    Science.gov (United States)

    Murphy, A P; Coudert, M; Barker, J

    2000-12-01

    There have been a number of studies investigating metal uptake in plants on contaminated landfill sites, but little on their role as biomarkers to identify metal mobility for continuous monitoring purposes. Vegetation can be used as a biomonitor of site pollution, by identifying the mobilisation of heavy metals and by providing an understanding of their bioavailability. Plants selected were the common nettle (Uritica Dioica), bramble (Rubus Fruticosa) and sycamore (Acer Pseudoplatanus). A study of the soil fractionation was made to investigate the soil properties that are likely to influence metal mobility and a correlation exercise was undertaken to investigate if variations in concentration of metals in vegetation can reflect variations in concentration of the metals in soil. The soil was digested using aqua regia in a microwave closed vessel. The vegetation was digested using both microwave and a hydrogen peroxide-nitric acid mixture, refluxed on a heating block and a comparison made. The certified reference materials (CRMs) used were Standard Reference Material (SRM) 1547, peach leaves for vegetation (NIST) and for soil CRM 143R, sewage sludge-amended soil (BCR). The relative standard deviations (RSDs) were 2-6% for the analyses. Our findings show evidence of phytoextraction by some plants, (especially bramble and nettle), with certain plants, (sycamore) exhibiting signs of phytostabilisation. The evidence suggests that there is a degree of selectivity in metal uptake and partitioning within the plant compartments. It was also possible to correlate mobility phases of certain metals (Pb, Cu and Zn) using the soil and plant record. Zn and Cu exhibited the greatest potential to migrate from the roots to the leaves, with Pb found principally in the roots of ground vegetation. Our results suggest that analysis of bramble leaves, nettle leaves and roots can be used to monitor the mobility of Pb in the soil with nettle, bramble and sycamore leaves to monitor Cu and Zn.

  10. Application of Solid Phase Extraction on Multiwalled Carbon Nanotubes of Some Heavy Metal Ions to Analysis of Skin Whitening Cosmetics Using ICP-AES

    Directory of Open Access Journals (Sweden)

    Kamal Omer

    2013-01-01

    Full Text Available A novel and highly sensitive method for the determination of some heavy metals in skin whitening cosmetics creams using multiwalled carbon nanotubes MWCNTs as solid phase extraction sorbent for the preconcentration of these heavy metals prior to their determination by inductively coupled plasma atomic emission spectrometry is described. Different practical parameters have been thoroughly investigated and the optimum experimental conditions were employed. The developed method was then applied for the determination of arsenic, bismuth, cadmium, mercury, lead and titanium in samples of skin whitening cosmetics. The detection limits under these conditions for As, Bi, Cd, Pb, Hg and Ti were 2.4, 4.08, 0.3, 2.1, 1.8, and 1.8 ng·mL−1, respectively. The relative standard deviations (RSDs were found to be less than 2.0%. For validation, a certified reference material of NIST SRM 1570a spinach leaves was analyzed and the determined values were in good agreement with the certified values. The recoveries for spiked samples were found to be in the range of 89.6–104.4%.

  11. Application of Solid Phase Extraction on Multiwalled Carbon Nanotubes of Some Heavy Metal Ions to Analysis of Skin Whitening Cosmetics Using ICP-AES

    OpenAIRE

    ALqadami, Ayoub; Abdalla, Mohammad; ALOthman, Zeid; Omer, Kamal

    2013-01-01

    A novel and highly sensitive method for the determination of some heavy metals in skin whitening cosmetics creams using multiwalled carbon nanotubes MWCNTs as solid phase extraction sorbent for the preconcentration of these heavy metals prior to their determination by inductively coupled plasma atomic emission spectrometry is described. Different practical parameters have been thoroughly investigated and the optimum experimental conditions were employed. The developed method was then applied ...

  12. Application of solid phase extraction on multiwalled carbon nanotubes of some heavy metal ions to analysis of skin whitening cosmetics using ICP-AES.

    Science.gov (United States)

    Alqadami, Ayoub A; Abdalla, Mohammad Abulhassan; AlOthman, Zeid A; Omer, Kamal

    2013-01-14

    A novel and highly sensitive method for the determination of some heavy metals in skin whitening cosmetics creams using multiwalled carbon nanotubes MWCNTs as solid phase extraction sorbent for the preconcentration of these heavy metals prior to their determination by inductively coupled plasma atomic emission spectrometry is described. Different practical parameters have been thoroughly investigated and the optimum experimental conditions were employed. The developed method was then applied for the determination of arsenic, bismuth, cadmium, mercury, lead and titanium in samples of skin whitening cosmetics. The detection limits under these conditions for As, Bi, Cd, Pb, Hg and Ti were 2.4, 4.08, 0.3, 2.1, 1.8, and 1.8 ng·mL-1, respectively. The relative standard deviations (RSDs) were found to be less than 2.0%. For validation, a certified reference material of NIST SRM 1570a spinach leaves was analyzed and the determined values were in good agreement with the certified values. The recoveries for spiked samples were found to be in the range of 89.6-104.4%.

  13. Determination of carboxylic acids, carbohydrates and metals in different tomato cultivars by HPLC-ICP-AES in a single chromatographic run

    OpenAIRE

    Paredes Paredes, Eduardo; Maestre, Salvador E.; Prats Moya, Soledad; Todolí Torró, José Luis

    2007-01-01

    Póster presentado en European Winter Conference on Plasma Spectrochemistry 2007, 18-23 February 2007, Taormina, Italy The determination of carbohydrates, carboxylic acids and metals is a subject of great interest in the field of food science because their presence and concentration can influence on food quality. Besides the study of the profiles of these compounds can permit the discrimination between different varieties of a product. Unfortunately, the usually employed chromatograph...

  14. Standard test method for determination of impurities in plutonium: acid dissolution, ion exchange matrix separation, and inductively coupled plasma-atomic emission spectroscopic (ICP/AES) analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This specification covers blended uranium trioxide (UO3), U3O8, or mixtures of the two, powders that are intended for conversion into a sinterable uranium dioxide (UO2) powder by means of a direct reduction process. The UO2 powder product of the reduction process must meet the requirements of Specification C 753 and be suitable for subsequent UO2 pellet fabrication by pressing and sintering methods. This specification applies to uranium oxides with a 235U enrichment less than 5 %. 1.2 This specification includes chemical, physical, and test method requirements for uranium oxide powders as they relate to the suitability of the powder for storage, transportation, and direct reduction to UO2 powder. This specification is applicable to uranium oxide powders for such use from any source. 1.3 The scope of this specification does not comprehensively cover all provisions for preventing criticality accidents, for health and safety, or for shipping. Observance of this specification does not relieve the user of th...

  15. Determination of total Cr in wastewaters of Cr electroplating factories in the I.organize industry region (Kayseri, Turkey) by ICP-AES.

    Science.gov (United States)

    Yilmaz, Selehattin; Türe, Melike; Sadikoglu, Murat; Duran, Ali

    2010-08-01

    The wastewater pollution in industrial areas is one of the most important environmental problems. Heavy metal pollution, especially chromium pollution in the wastewater sources from electroplating, dyeing, and tannery, has affected the life on earth. This pollution can affect on all ecosystems and human health directly or by food chain. Therefore, the determination of total chromium in this study is of great importance. In this study, accurate, rapid, sensitive, selective, simple, and low-cost technique for the direct determination of total Cr in wastewater samples collected from the some Cr electroplating factories in March 2008 by inductively coupled plasma-atomic emission spectrometry has been developed. The analysis of a given sample is completed in about 15 min by this technique applied. As the result of the chromium analysis, the limit of quantification for the total Cr were founded to be over the limit value (0.05 mg L(-1); WHO, EPA, TSE 266, and inland water quality classification) as 1,898.78+/-0.34 mg/L at station 1 and 3,189.02+/-0.56 mg/L at station 2. The found concentration of total Cr has been determined to be IV class quality water according to the inland water classification. In order to validate the applied method, recovery studies were performed.

  16. Determination of neptunium in soil by ICP-MS

    International Nuclear Information System (INIS)

    Ayranov, M.; Kraehenbuehl, U.

    2005-01-01

    A fast and simple method for the determination of 237 Np in soil is presented. The borate fusion decreases the sample pre-treatment time and a TEVA extraction chromatography separates neptunium from uranium and the interfering matrix components. A comparison of the sensitivities of alpha spectrometry and sector field ICP-MS for determination of 237 Np is presented. (orig.)

  17. Air ICP uses for instantaneous monitoring of airborne pollutants

    International Nuclear Information System (INIS)

    Thouzeau, F.; Birolleau, J.C.; Fieni, J.M.; Bergey, C.

    1987-01-01

    Recently the development of a pure AIR-ICP which breathes in and excites the analysed air without sample dilution, allowed the application of this technique to the real time analysis of airborne metallic pollutants. First results obtained on airborne Beryllium in a laboratory and a test-site apparatus are presented in this paper

  18. Some practical applications of an ICP-MS instrument

    International Nuclear Information System (INIS)

    Meddings, B.; Ng, R.

    1987-01-01

    An early model commercial ICP-MS instrument (PlasmaQuad from VG Isotopes Limited) was acquired more than two years ago. As a typical analytical laboratory in the metallurgical field, the application of the ICP-MS technique to real sample analysis is the authors prime concern. The process of introducing this state-of-the-art instrument into routine analysis will be described. The modifications and limitations necessary to achieve acceptable precision under normal working conditions will be outlined. In most cases, practical problems can be circumvented with some sacrifice in analytical performance in the area of detection limits and dynamic range. In this presentation, specific applications of the ICP-MS technique in the authors laboratory will be discussed. These include trace analysis on high purity metals such as copper, aluminum, cobalt, nickel etc., on refinery feed samples such as nickel sulfate, mixed cobalt and nickel sulfide, cobalt cathode, samarium oxide etc., on alloys such as cobalt-samarium magnetic materials, nickel or cobalt based alloys used in turbine blades etc. Other applications such as the determination of uranium in phosphate rock, trace analysis on fertilizers, water samples and high purity acids will also be mentioned. The solutions to the practical problems encountered in these applications will be discussed. The analytical power of the ICP-MS technique for real sample analysis will be assessed

  19. LA-ICP-MS zircon U-Pb geochronology to constrain the age of post-Neocomian continental deposits of the Cerrillos Formation, Atacama Region , northern Chile: tectonic and metallogenic implications Geocronología U-Pb en circón por LA-ICP-MS para circunscribir la edad de depósitos continentales post-neocomianos de la Formacion Cerrillos, Región de Atacama, norte de Chile: implicancias tectónicas y metalogénicas

    Directory of Open Access Journals (Sweden)

    Víctor Maksaev

    2009-07-01

    para la parte superior volcánica de la Formacion Cerrillos, sugiere la recurrencia del volcanismo en el Cretácico Tardío, más que la continuidad de la actividad volcánica. Una edad mínima Maastrichtiano tardío para la Formacion Cerrillos y su primera etapa de deformacion se determinó por el rango de edades U-Pb de 66,9±1,0 a 65,2±1,0 Ma para la parte inferior de la suprayacente, discordante Formacion Hornitos. LosdatosU-Pb para laFormacion Hornitosplanteaninterrogantesrespecto al rango Campaniano-Maastrichtiano actualmente asignado a esta unidad. La parte inferior de la Formacion Cerrillos representa un cambio mayor en el régimen sedimentario desde la sedimentacion previa calcarea marina en una cuenca de trasarco hasta el Aptiano tardío a una subsecuente sedimentacion aluvial gruesa y volcanismo a partir del Albiano temprano. La parte inferior de la Formacion Cerrillos se interpreta como conos aluviales coalescentes que se adelgazan hacia el interior continental acompañados de volcanismo. Su desarrollo estuvo ligado a la deformacion transpresiva y alzamiento del area de la actual Cordillera de la Costa en el Aptiano tardío, lo que condujo a su erosion y sedimentacion hacia el interior continental, junto con la migracion hacia el este del eje magmático en la Región . Un período de mineralizacion de pórfidos de Cu-Au se traslapa en el tiempo con la depositacion de la Formacion Cerrillos y marca también un cambio importante en la metalogénesis de Los Andes del norte de Chile.

  20. Quality and Safety of Home ICP Monitoring Compared with In-Hospital Monitoring

    DEFF Research Database (Denmark)

    Andresen, Morten; Juhler, Marianne; Munch, Tina Nørgaard

    2012-01-01

    Introduction: Intracranial pressure (ICP) monitoring is usually conducted in-hospital using stationary devices. Modern mobile ICP monitoring systems present new monitoring possibilities more closely following the patients' daily life. We reviewed patient safety, quality of technical data...

  1. Molecular Characterization of Prostate Cancer Cell Oncolysis by Herpes Simplex Virus ICP0 Mutants

    National Research Council Canada - National Science Library

    Mossman, Karen

    2006-01-01

    .... Briefly, the goals of the proposal were to characterize the oncolytic capacity of Herpes simplex virus type 1 ICP0 mutants in prostate cancer cells given the relationship between ICP0 and two tumor...

  2. Significado prognóstico das micrometástases nos linfonodos do carcinoma colorretal: detecção imunoistoquímica com anticorpos anticitoqueratina AE1/AE3

    Directory of Open Access Journals (Sweden)

    Rogério Tadeu Palma

    Full Text Available OBJETIVOS: Identificar por imunoistoquímica eventuais micrometástases nos linfonodos regionais previamente considerados livres pelo exame histopatológico convencional e avaliar a influência do comprometimento destes linfonodos na sobrevivência dos doentes com carcinoma colorretal extirpado com intenção curativa. MÉTODO: Foram estudados 51 doentes portadores de carcinoma colorretal nos estádios A (13 casos e B (38 casos, segundo a classificação de Dukes. Um total de 501 linfonodos previamente considerados livres pelo exame histopatológico convencional foi investigado por meio de técnica imunoistoquímica com anticorpos monoclonais anticitoqueratina AE1/AE3 para identificar células epiteliais. Cada bloco previamente fixado em formalina e embebido em parafina foi seccionado em três partes, obtendo-se de cada uma delas três cortes com espessura de 4 milimícron cada. RESULTADOS: Em seis doentes (11,7% no estádio B de Dukes, células neoplásicas foram identificadas em sete linfonodos do mesocolo (1,4% previamente considerados livres de neoplasia pelo exame histopatológico convencional. Em um enfermo, a micrometástase era representada por aglomerado celular, enquanto que nos outros cinco doentes as micrometástases eram constituídas por células isoladas. A sobrevivência dos enfermos com micrometástases linfonodais foi menor do que a dos doentes com linfonodos não comprometidos, porém sem atingir diferença significativa. CONCLUSÕES: O método imunoistoquímico pode ser empregado com sucesso na detecção de células neoplásicas em linfonodos previamente considerados livres pelo exame histopatológico convencional. O acometimento dos linfonodos regionais por micrometástases não influenciou a sobrevivência dos doentes com carcinoma colorretal extirpado.

  3. The use of MP-AES for determination of plant available P in soil by DL method and distribution of soils into P status classes by DL, AL and Mehlich 3 methods.

    Science.gov (United States)

    Toomsoo, Avo; Jürgens, Meit; Kõlli, Raimo; Künnapas, Allan; Albre, Imbi; Tõnutare, Tõnu; Rodima, Ako

    2017-04-01

    Only small percentage of soil total phosphorus is easily exchangeable between solid and solution phase. Plants are able to assimilate P from environment only in the form of orthophosphate ions (H2PO4- and HPO42-) from soil solution. Deficit of P in soil solution prevents plant normal growth and decreases yield quantity and quality. The excess of P in soil solution causes the pollution of environment and eutrophication of water bodies. Therefore it is important to give to the plant producers the correct fertilization recommendations. Lot of analytical methods are developed for the determination of plant available P in soils. In the Baltic Sea region seven different soils' P analysis methods in use. Each method has its own gradation and often there is more than one gradation for the same method depending from agroecological conditions. For agricultural soils in Estonia there are soil P status gradations according to Mehlich 3, DL and AL methods. Phosphate content in soil can be determined by molybdate method Vis-spectrometrically. Very often for analysis of soils' P content also ICP-OES, ICP-MS and also MP-AES instrumental methods are used The aim of our work was to investigate the possibility of using MP-AES for determination of plant available P in soil by DL method and also to compare how the analysed soils are distributed to M3, AL and DL fertilizer requirement groups according to the P content.

  4. Generic demonstration plant study (A/E package)

    International Nuclear Information System (INIS)

    Molzen, D.F.

    1979-01-01

    Molzen--Corbin and Associates, Albuquerque, New Mexico, under contract to Sandia Laboratories, has prepared preliminary drawings, descriptive material and a scale model of the demonstration plant. This information will be made available to A/E firms to assist them in the preparation of proposals for complete construction plans and specifications. The four categories for which preliminary work has been prepared consist of structural work, mechanical work, electrical work, and cost estimates. In addition, preliminary specifications, including a written description of the facility consisting of mechanical electrical systems and operations, a description of the safety features, the basic design criteria, three-dimensional sketches, and a scale model of the design have been prepared. The preliminary drawings indicate the required minimum wall thicknesses, overall dimensions and the necessary layout of the removable concrete blocks and slabs required for radiation protection and control

  5. Performance analysis of AES-Blowfish hybrid algorithm for security of patient medical record data

    Science.gov (United States)

    Mahmud H, Amir; Angga W, Bayu; Tommy; Marwan E, Andi; Siregar, Rosyidah

    2018-04-01

    A file security is one method to protect data confidentiality, integrity and information security. Cryptography is one of techniques used to secure and guarantee data confidentiality by doing conversion to the plaintext (original message) to cipher text (hidden message) with two important processes, they are encrypt and decrypt. Some researchers proposed a hybrid method to improve data security. In this research we proposed hybrid method of AES-blowfish (BF) to secure the patient’s medical report data into the form PDF file that sources from database. Generation method of private and public key uses two ways of approach, those are RSA method f RSA and ECC. We will analyze impact of these two ways of approach for hybrid method at AES-blowfish based on time and Throughput. Based on testing results, BF method is faster than AES and AES-BF hybrid, however AES-BF hybrid is better for throughput compared with AES and BF is higher.

  6. Competence of Aedes aegypti, Ae. albopictus, and Culex quinquefasciatus Mosquitoes as Zika Virus Vectors, China

    Science.gov (United States)

    Liu, Zhuanzhuan; Zhou, Tengfei; Lai, Zetian; Zhang, Zhenhong; Jia, Zhirong; Zhou, Guofa; Williams, Tricia; Xu, Jiabao; Gu, Jinbao; Zhou, Xiaohong; Lin, Lifeng; Yan, Guiyun

    2017-01-01

    In China, the prevention and control of Zika virus disease has been a public health threat since the first imported case was reported in February 2016. To determine the vector competence of potential vector mosquito species, we experimentally infected Aedes aegypti, Ae. albopictus, and Culex quinquefasciatus mosquitoes and determined infection rates, dissemination rates, and transmission rates. We found the highest vector competence for the imported Zika virus in Ae. aegypti mosquitoes, some susceptibility of Ae. albopictus mosquitoes, but no transmission ability for Cx. quinquefasciatus mosquitoes. Considering that, in China, Ae. albopictus mosquitoes are widely distributed but Ae. aegypti mosquito distribution is limited, Ae. albopictus mosquitoes are a potential primary vector for Zika virus and should be targeted in vector control strategies. PMID:28430562

  7. Competence of Aedes aegypti, Ae. albopictus, and Culex quinquefasciatus Mosquitoes as Zika Virus Vectors, China.

    Science.gov (United States)

    Liu, Zhuanzhuan; Zhou, Tengfei; Lai, Zetian; Zhang, Zhenhong; Jia, Zhirong; Zhou, Guofa; Williams, Tricia; Xu, Jiabao; Gu, Jinbao; Zhou, Xiaohong; Lin, Lifeng; Yan, Guiyun; Chen, Xiao-Guang

    2017-07-01

    In China, the prevention and control of Zika virus disease has been a public health threat since the first imported case was reported in February 2016. To determine the vector competence of potential vector mosquito species, we experimentally infected Aedes aegypti, Ae. albopictus, and Culex quinquefasciatus mosquitoes and determined infection rates, dissemination rates, and transmission rates. We found the highest vector competence for the imported Zika virus in Ae. aegypti mosquitoes, some susceptibility of Ae. albopictus mosquitoes, but no transmission ability for Cx. quinquefasciatus mosquitoes. Considering that, in China, Ae. albopictus mosquitoes are widely distributed but Ae. aegypti mosquito distribution is limited, Ae. albopictus mosquitoes are a potential primary vector for Zika virus and should be targeted in vector control strategies.

  8. Continuous AE monitoring of nuclear plants to detect flaws - status and future

    International Nuclear Information System (INIS)

    Hutton, P.H.

    1986-01-01

    This paper gives a brief commentary on the evolution of acoustic emission (AE) technology for continuous monitoring of nuclear reactors and the current status. The technical work described to support the status description has the objective of developing and validating the use of AE to detect, locate, and evaluate growing flaws in reactor pressure boundaries. The future of AE for continuous monitoring is discussed in terms of envisioned applications and further accomplishments required to achieve them. 12 refs.

  9. Global Dispersal Pattern of HIV Type 1 Subtype CRF01_AE

    OpenAIRE

    Poljak, Mario; Angelis, Konstantinos; Albert, Jan; Mamais, Ioannis; Magiorkinis, Gkikas; Hatzakis, Angelos; Hamouda, Osamah; Stuck, Daniel; Vercauteren, Jurgen; Wensing, Annemarie; Alexiev, Ivailo

    2016-01-01

    Background. Human immunodeficiency virus type 1 (HIV-1) subtype CRF01_AE originated in Africa and then passed to Thailand, where it established a major epidemic. Despite the global presence of CRF01_AE, little is known about its subsequent dispersal pattern. Methods. We assembled a global data set of 2736 CRF01_AE sequences by pooling sequences from public databases and patient-cohort studies. We estimated viral dispersal patterns, using statistical phylogeographic analysis run over bootstrap...

  10. Evaluation of fracturing process of soft rocks at great depth by AE measurement and DEM simulation

    International Nuclear Information System (INIS)

    Aoki, Kenji; Mito, Yoshitada; Kurokawa, Susumu; Matsui, Hiroya; Niunoya, Sumio; Minami, Masayuki

    2007-01-01

    The authors developed the stress-based evaluation system of EDZ by AE monitoring and Distinct Element Method (DEM) simulation. In order to apply this system to the soft rock site, the authors try to grasp the relationship between AE parameters, stress change and rock fracturing process by performing the high stiffness tri-axial compression tests including AE measurements on the soft rock samples, and its simulations by DEM using bonded particle model. As the result, it is found that change in predominant AE frequency is effective to evaluate fracturing process in sedimentary soft rocks, and the relationship between stress change and fracturing process is also clarified. (author)

  11. Genome-Wide Identification and Expression Analysis of the UGlcAE Gene Family in Tomato

    OpenAIRE

    Xing Ding; Jinhua Li; Yu Pan; Yue Zhang; Lei Ni; Yaling Wang; Xingguo Zhang

    2018-01-01

    The UGlcAE has the capability of interconverting UDP-d-galacturonic acid and UDP-d-glucuronic acid, and UDP-d-galacturonic acid is an activated precursor for the synthesis of pectins in plants. In this study, we identified nine UGlcAE protein-encoding genes in tomato. The nine UGlcAE genes that were distributed on eight chromosomes in tomato, and the corresponding proteins contained one or two trans-membrane domains. The phylogenetic analysis showed that SlUGlcAE genes could be divided into s...

  12. Structure of the Aeropyrum pernix L7Ae multifunctional protein and insight into its extreme thermostability

    International Nuclear Information System (INIS)

    Bhuiya, Mohammad Wadud; Suryadi, Jimmy; Zhou, Zholi; Brown, Bernard Andrew II

    2013-01-01

    The crystal structure of A. pernix L7Ae is reported, providing insight into the extreme thermostability of this protein. Archaeal ribosomal protein L7Ae is a multifunctional RNA-binding protein that directs post-transcriptional modification of archaeal RNAs. The L7Ae protein from Aeropyrum pernix (Ap L7Ae), a member of the Crenarchaea, was found to have an extremely high melting temperature (>383 K). The crystal structure of Ap L7Ae has been determined to a resolution of 1.56 Å. The structure of Ap L7Ae was compared with the structures of two homologs: hyperthermophilic Methanocaldococcus jannaschii L7Ae and the mesophilic counterpart mammalian 15.5 kD protein. The primary stabilizing feature in the Ap L7Ae protein appears to be the large number of ion pairs and extensive ion-pair network that connects secondary-structural elements. To our knowledge, Ap L7Ae is among the most thermostable single-domain monomeric proteins presently observed

  13. Spontaneous wheat-Aegilops biuncialis, Ae. geniculata and Ae. triuncialis amphiploid production, a potential way of gene transference

    Energy Technology Data Exchange (ETDEWEB)

    Loureiro, I.; Escorial, C.; Garcia-Baudin, J. M.; Chueca, M. C.

    2009-07-01

    Some F1 hybrid plants between three species of the Aegilops genus and different hexaploid wheat Triticum aestivum cultivars show certain self-fertility, with averages of F{sub 1} hybrids bearing F{sub 2} seeds of 8.17%, 5.12% and 48.14% for Aegilops biuncialis, Aegilops geniculata and Aegilops triuncialis respectively. In the Ae. triuncialis-wheat combination with Astral wheat cultivar, the fertility was higher than that found in the other combinations. All the F2 seeds studied were spontaneous amphiploids (2n=10x=70). The present study evidences the possibility of spontaneous formation of amphiploids between these three Aegilops species and hexaploid wheat and discusses their relevance for gene transference. Future risk assessment of transgenic wheat cultivars needs to evaluate the importance of amphiploids as a bridge for transgene introgression and for gene escape to the wild. (Author)

  14. LLNL large-area inductively coupled plasma (ICP) source: Experiments

    International Nuclear Information System (INIS)

    Richardson, R.A.; Egan, P.O.; Benjamin, R.D.

    1995-05-01

    We describe initial experiments with a large (76-cm diameter) plasma source chamber to explore the problems associated with large-area inductively coupled plasma (ICP) sources to produce high density plasmas useful for processing 400-mm semiconductor wafers. Our experiments typically use a 640-nun diameter planar ICP coil driven at 13.56 MHz. Plasma and system data are taken in Ar and N 2 over the pressure range 3-50 mtorr. RF inductive power was run up to 2000W, but typically data were taken over the range 100-1000W. Diagnostics include optical emission spectroscopy, Langmuir probes, and B probes as well as electrical circuit measurements. The B and E-M measurements are compared with models based on commercial E-M codes. Initial indications are that uniform plasmas suitable for 400-mm processing are attainable

  15. Integrated care pathways for airway diseases (AIRWAYS-ICPs)

    DEFF Research Database (Denmark)

    Bousquet, J; Addis, A; Adcock, I

    2014-01-01

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy...... and will add value to existing public health knowledge by: 1) proposing a common framework of care pathways for chronic respiratory diseases, which will facilitate comparability and trans-national initiatives; 2) informing cost-effective policy development, strengthening in particular those on smoking...... and environmental exposure; 3) aiding risk stratification in chronic disease patients, using a common strategy; 4) having a significant impact on the health of citizens in the short term (reduction of morbidity, improvement of education in children and of work in adults) and in the long-term (healthy ageing); 5...

  16. CHANDRA HIGH-ENERGY TRANSMISSION GRATING SPECTRUM OF AE AQUARII

    International Nuclear Information System (INIS)

    Mauche, Christopher W.

    2009-01-01

    The nova-like cataclysmic binary AE Aqr, which is currently understood to be a former supersoft X-ray binary and current magnetic propeller, was observed for over two binary orbits (78 ks) in 2005 August with the High-Energy Transmission Grating (HETG) on board the Chandra X-ray Observatory. The long, uninterrupted Chandra observation provides a wealth of details concerning the X-ray emission of AE Aqr, many of which are new and unique to the HETG. First, the X-ray spectrum is that of an optically thin multi-temperature thermal plasma; the X-ray emission lines are broad, with widths that increase with the line energy from σ ∼ 1 eV (510 km s -1 ) for O VIII to σ ∼ 5.5 eV (820 km s -1 ) for Si XIV; the X-ray spectrum is reasonably well fit by a plasma model with a Gaussian emission measure distribution that peaks at log T(K) = 7.16, has a width σ = 0.48, an Fe abundance equal to 0.44 times solar, and other metal (primarily Ne, Mg, and Si) abundances equal to 0.76 times solar; and for a distance d = 100 pc, the total emission measure EM = 8.0 x 10 53 cm -3 and the 0.5-10 keV luminosity L X = 1.1 x 10 31 erg s -1 . Second, based on the f/(i + r) flux ratios of the forbidden (f), intercombination (i), and recombination (r) lines of the Heα triplets of N VI, O VII, and Ne IX measured by Itoh et al. in the XMM-Newton Reflection Grating Spectrometer spectrum and those of O VII, Ne IX, Mg XI, and Si XIII in the Chandra HETG spectrum, either the electron density of the plasma increases with temperature by over three orders of magnitude, from n e ∼ 6 x 10 10 cm -3 for N VI [log T(K) ∼ 6] to n e ∼ 1 x 10 14 cm -3 for Si XIII [log T(K) ∼ 7], and/or the plasma is significantly affected by photoexcitation. Third, the radial velocity of the X-ray emission lines varies on the white dwarf spin phase, with two oscillations per spin cycle and an amplitude K ∼ 160 km s -1 . These results appear to be inconsistent with the recent models of Itoh et al., Ikhsanov, and

  17. Fundamental studies of interferences in ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Rowley, L.K

    2000-11-01

    Methods of temperature measurement by mass spectrometry have been critically reviewed. It was concluded that the most appropriate method depended critically on the availability of fundamental data, hence a database of fundamental spectroscopic constants, for diatomic ions which cause interferences in ICP-MS, was compiled. The equilibration temperature, calculated using the different methods and using various diatomic ions as the thermometric probes, was between c.a. 400 - 10,000 K in the central channel, and between c.a. 600 - 16,000 K when the plasma was moved 1.8 mm off-centre. The wide range in temperature reflected the range of temperature measurement methods and uncertainty in the fundamental data. Optical studies using a fibre optic connected to a monochromator were performed in order to investigate the presence of interferences both in the plasma and the interface region of the ICP-MS, and the influence of a shielded torch on these interferences. It was possible to determine the presence of some species in the plasma, such as the strongly bound metal oxides, however, no species other than OH were detected in the interface region of the ICP-MS. The OH rotational temperature within the interface region of the ICP-MS was calculated to be between 2,000 - 4,000 K. The effect of sampling depth, operating power, radial position and solvent loading, with and without the shielded torch, on the dissociation temperature of a variety of polyatomic interferences was investigated. These calculated temperatures were then used to elucidate the site of formation for different polyatomic interferences. Results confirmed that strongly bound ions such as MO{sup +} were formed in the plasma, whereas weakly bound ions such as ArO{sup +} were formed in the interface region due to gross deviation of the calculated temperatures from those expected for a system in thermal equilibrium. (author)

  18. 3D printing for cyclonic spray chambers in ICP spectrometry

    OpenAIRE

    Geertsen , Valérie; Barruet , Elodie; Tache , Olivier

    2015-01-01

    International audience; Additive manufacturing (AM) or 3D-printing is an increasingly widespread technique which is often described as a source for rapid prototyping whereas it is a manufacturing process in itself. It is a new tool for instrumental research laboratories which can now easily manufacture by themselves a large variety of devices. This article describes its application to ICP introduction system spray chambers. We undertake to print and study cyclone spray chambers by combining a...

  19. Theoretical characterization of quaternary iridium based hydrides NaAeIrH{sub 6} (Ae = Ca, Ba and Sr)

    Energy Technology Data Exchange (ETDEWEB)

    Bouras, S. [Laboratory of Studies Surfaces and Interfaces of Solids Materials, Department of Physics, Faculty of Science, University of Setif 1, 19000 (Algeria); Ghebouli, B., E-mail: bghebouli@yahoo.fr [Laboratory of Studies Surfaces and Interfaces of Solids Materials, Department of Physics, Faculty of Science, University of Setif 1, 19000 (Algeria); Benkerri, M. [Laboratory of Studies Surfaces and Interfaces of Solids Materials, Department of Physics, Faculty of Science, University of Setif 1, 19000 (Algeria); Ghebouli, M.A., E-mail: med.amineghebouli@yahoo.fr [Microelectronic Laboratory (LMSE), University of Bachir Ibrahimi, Bordj-Bou-Arreridj 34000 (Algeria); Research Unit on Emerging Materials (RUEM), University of Setif 1, 19000 (Algeria); Choutri, H. [Microelectronic Laboratory (LMSE), University of Bachir Ibrahimi, Bordj-Bou-Arreridj 34000 (Algeria); Louail, L.; Chihi, T.; Fatmi, M. [Research Unit on Emerging Materials (RUEM), University of Setif 1, 19000 (Algeria); Bouhemadou, A. [Laboratory for Developing New Materials and Their Characterization, Department of Physics, Faculty of Science, University of Setif 1, 19000 (Algeria); Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451 (Saudi Arabia); Khenata, R.; Khachai, H. [Laboratoire de Physique Quantique et de Modélisation Mathématique, Université de Mascara, 29000 (Algeria)

    2015-01-15

    The quaternary iridium based hydrides NaAeIrH{sub 6} (Ae = Ca, Ba and Sr) are promising candidates as hydrogen storage materials. We have studied the structural, elastic, electronic, optical and thermodynamic properties of NaAeIrH{sub 6} (Ae = Ca, Ba and Sr) within the generalized gradient approximation, the local density approximation (LDA) and mBj in the frame of density functional perturbation theory. These alloys have a large indirect Γ–X band gap. The thermodynamic functions were computed using the phonon density of states. The origin of the possible transitions from valence band to conduction band was illustrated. By using the complex dielectric function, the optical properties such as absorption, reflectivity, loss function, refractive index and optical conductivity have been obtained. - Graphical abstract: Real and imaginary parts of the dielectric function, the absorption spectrum α(ω), reflectivity R(ω) and energy-loss spectrum L(ω). - Highlights: • NaAeIrH{sub 6} (Ae = Ca, Ba and Sr) alloys have been investigated. • The elastic moduli, energy gaps are predicted. • The optical and thermal properties were studied.

  20. Preliminary study of acoustic emission (ae) noise signal identification for crude oil storage tank

    International Nuclear Information System (INIS)

    Nurul Ain Ahmad Latif; Shukri Mohd

    2008-08-01

    This preliminary work was carried out to simulate the Acoustic Emission (AE) signal contributed by pitting corrosion, and noise signal from environment during crude oil storage tanks monitoring. The purpose of this study is to prove that acoustic emission (AE) could be used to detect the formation of pitting corrosion in the crude oil storage tank and differentiated it from other sources of noise signal. In this study, the pitting corrosion was simulated by inducing low voltage and low amperage current onto the crude oil storage tank material (ASTM 516 G 70). Water drop, air blow and surface rubbing were applied onto the specimen surface. To simulate the noise signal produce by rain fall, wind blow and other sources of noise during AE crude oil storage tanks monitoring. AE sensor was attached onto the other surface of specimen to acquire all of these AE signals which then has send to AE DiSP 24 data acquisition system for signal conditioning. AE win software has been used to analyse this entire signal. It is found that, simulated pitting corrosion could be detected by AE system and differentiated from other sources of noise by using amplitude analysis. From the amplitude analysis is shown that 20-30 dB is the range amplitude for the blow test, 50-60 dB for surface rubbing test and over than 60 dB for water drop test. (Author)

  1. AE characteristic for monitoring of fatigue crack in steel bridge members

    Science.gov (United States)

    Yoon, Dong-Jin; Jung, Juong-Chae; Park, Philip; Lee, Seung-Seok

    2000-06-01

    Acoustic emission technique was employed for the monitoring of crack activity in both steel bridge members and laboratory specimen. Laboratory experiment was carried out to identify AE characteristics of fatigue cracks for compact tension specimen. The relationship between a stress intensity factor and AE signals activity as well as conventional AE parameter analysis was discussed. A field test was also conducted on a railway bridge, which contain several fatigue cracks. Crack activities were investigated while in service with strain measurement. From the results, in the laboratory tests, the features of three parameters such as the length of crack growth, the AE energy, and the cumulative AE events, showed the almost same trend in their increase as the number of fatigue cycle increased. From the comparisons of peak amplitude and AE energy with stress intensity factor, it was verified that the higher stress intensity factors generated AE signals with higher peak amplitude and a large number of AE counts. In the field test, real crack propagation signals were captured and the crack activity was verified in two cases.

  2. Low-area hardware implementations of CLOC, SILC and AES-OTR

    DEFF Research Database (Denmark)

    Banik, Subhadeep; Bogdanov, Andrey; Minematsu, Kazuhiko

    2016-01-01

    The most compact implementation of the AES-128 algorithm was the 8-bit serial circuit proposed in the work of Moradi et. al. (Eurocrypt 2011). The circuit has an 8-bit datapath and occupies area equivalent to around 2400 GE. Since many authenticated encryption modes use the AES-128 algorithm...

  3. AES based secure low energy adaptive clustering hierarchy for WSNs

    Science.gov (United States)

    Kishore, K. R.; Sarma, N. V. S. N.

    2013-01-01

    Wireless sensor networks (WSNs) provide a low cost solution in diversified application areas. The wireless sensor nodes are inexpensive tiny devices with limited storage, computational capability and power. They are being deployed in large scale in both military and civilian applications. Security of the data is one of the key concerns where large numbers of nodes are deployed. Here, an energy-efficient secure routing protocol, secure-LEACH (Low Energy Adaptive Clustering Hierarchy) for WSNs based on the Advanced Encryption Standard (AES) is being proposed. This crypto system is a session based one and a new session key is assigned for each new session. The network (WSN) is divided into number of groups or clusters and a cluster head (CH) is selected among the member nodes of each cluster. The measured data from the nodes is aggregated by the respective CH's and then each CH relays this data to another CH towards the gateway node in the WSN which in turn sends the same to the Base station (BS). In order to maintain confidentiality of data while being transmitted, it is necessary to encrypt the data before sending at every hop, from a node to the CH and from the CH to another CH or to the gateway node.

  4. Test and acceptance from the AE point of view

    International Nuclear Information System (INIS)

    Sommer, W.C.

    1976-01-01

    The power industry has undergone the transition from utilizing construction engineers for startup activities to utilizing test engineers who are responsible for the preparation or execution of a formal test program. This has come about because testing has been given sufficient importance to justify those participating within the industry to establish it as a specialty phase apart from engineering/design and construction. Presently testing is being conducted by those organizations that have either engineered and/or constructed the unit which may be a position of conflict in regards to unbiased test. The tester (third party) concept promotes the repetition, independence, and expertise of a test organization responsible to the utility for certifying that each system has been tested to the design criteria established by others. A move to this concept should result in better generating stations with higher availability because it has been completely tested by an organization with this sole contractual responsibility. The AE, NSSS, and utility would all benefit with possibly no additional costs incurred

  5. AE Monitoring of Diamond Turned Rapidly Soldified Aluminium 443

    International Nuclear Information System (INIS)

    Onwuka, G; Abou-El-Hossein, K; Mkoko, Z

    2017-01-01

    The fast replacement of conventional aluminium with rapidly solidified aluminium alloys has become a noticeable trend in the current manufacturing industries involved in the production of optics and optical molding inserts. This is as a result of the improved performance and durability of rapidly solidified aluminium alloys when compared to conventional aluminium. Melt spinning process is vital for manufacturing rapidly solidified aluminium alloys like RSA 905, RSA 6061 and RSA 443 which are common in the industries today. RSA 443 is a newly developed alloy with few research findings and huge research potential. There is no available literature focused on monitoring the machining of RSA 443 alloys. In this research, Acoustic Emission sensing technique was applied to monitor the single point diamond turning of RSA 443 on an ultrahigh precision lathe machine. The machining process was carried out after careful selection of feed, speed and depths of cut. The monitoring process was achieved with a high sampling data acquisition system using different tools while concurrent measurement of the surface roughness and tool wear were initiated after covering a total feed distance of 13km. An increasing trend of raw AE spikes and peak to peak signal were observed with an increase in the surface roughness and tool wear values. Hence, acoustic emission sensing technique proves to be an effective monitoring method for the machining of RSA 443 alloy. (paper)

  6. Development of ICP-MS and ICP-OES methods for determination of gadolinium in samples related to hospital waste water treatment

    Czech Academy of Sciences Publication Activity Database

    Bendakovská, L.; Krejčovská, A.; Černohorský, T.; Zelenková, Jana

    2016-01-01

    Roč. 70, č. 9 (2016), s. 1155-1165 ISSN 0366-6352 Institutional support: RVO:67985874 Keywords : gadolinium * rare-earth elements * bioaccumulation * gadolinium anomaly * inductively coupled plasma mass spectrometry (ICP-MS) * inductively coupled plasma optical emission spectrometry (ICP-OES) Subject RIV: BK - Fluid Dynamics Impact factor: 1.258, year: 2016

  7. A Study on AE Signal Analysis of Composite Materials Using Matrix Piezo Electric Sensor

    International Nuclear Information System (INIS)

    Yu, Yeun Ho; Choi, Jin Ho; Kweon, Jin Hwe

    2007-01-01

    As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on non-destructive testing methods has become an important research area for improving their reliability and safety. AE (acoustic emission) can evaluate the defects by detecting the emitting strain energy when elastic waves are generated by the initiation and growth of crack, plastic deformation, fiber breakage, matrix cleavage, or delamination. In the paper, AE signals generated under uniaxial tension were measured and analyzed using the 8x8 matrix piezo electric sensor. The electronic circuit to control the transmitting distance of AE signals was designed and constructed. The optical data storage system was also designed to store the AE signal of 64 channels using LED (light emitting diode) elements. From the tests, it was shown that the source location and propagation path of AE signals in composite materials could be detected effectively by the 8x8 matrix piezo electric sensor

  8. Phylodynamic analysis of the dissemination of HIV-1 CRF01_AE in Vietnam.

    Science.gov (United States)

    Liao, Huanan; Tee, Kok Keng; Hase, Saiki; Uenishi, Rie; Li, Xiao-Jie; Kusagawa, Shigeru; Thang, Pham Hong; Hien, Nguyen Tran; Pybus, Oliver G; Takebe, Yutaka

    2009-08-15

    To estimate the epidemic history of HIV-1 CRF01_AE in Vietnam and adjacent Guangxi, China, we determined near full-length nucleotide sequences of CRF01_AE from a total of 33 specimens collected in 1997-1998 from different geographic regions and risk populations in Vietnam. Phylogenetic and Bayesian molecular clock analyses were performed to estimate the date of origin of CRF01_AE lineages. Our study reconstructs the timescale of CRF01_AE expansion in Vietnam and neighboring regions and suggests that the series of CRF01_AE epidemics in Vietnam arose by the sequential introduction of founder strains into new locations and risk groups. CRF01_AE appears to have been present among heterosexuals in South-Vietnam for more than a decade prior to its epidemic spread in the early 1990s. In the late 1980s, the virus spread to IDUs in Southern Vietnam and subsequently in the mid-1990s to IDUs further north. Our results indicate the northward dissemination of CRF01_AE during this time.

  9. Analysis of impurities in uranium oxide by ICP-MS

    International Nuclear Information System (INIS)

    Paul, M.; Hager, J.

    1989-01-01

    The method offers detection limits of less than 0.1 μg/g in solid samples and a wide linear dynamic working range and allows a fast sample throughput. The poster summarizes recent authors' experience with the analysis of high purity uranium oxide. The samples are analyzed using both conventional solution analysis and solid sampling method, using a new powerful laser sampling system attached to the ICP mass spectrometer. The total analysis time required for one uranium oxide sample is about 4 minutes including sample handling, data acquisition and processing. The results achieved from semiquantitative and quantitative analysis applying both techniques are in good agreement with the reference values. (author)

  10. Elemental Analysis in Biological Matrices Using ICP-MS.

    Science.gov (United States)

    Hansen, Matthew N; Clogston, Jeffrey D

    2018-01-01

    The increasing exploration of metallic nanoparticles for use as cancer therapeutic agents necessitates a sensitive technique to track the clearance and distribution of the material once introduced into a living system. Inductively coupled plasma mass spectrometry (ICP-MS) provides a sensitive and selective tool for tracking the distribution of metal components from these nanotherapeutics. This chapter presents a standardized method for processing biological matrices, ensuring complete homogenization of tissues, and outlines the preparation of appropriate standards and controls. The method described herein utilized gold nanoparticle-treated samples; however, the method can easily be applied to the analysis of other metals.

  11. Molecular epidemiological study of HIV-1 CRF01_AE transmission in Hong Kong.

    Science.gov (United States)

    Chen, J H K; Wong, K H; Li, P; Chan, K C; Lee, M P; Lam, H Y; Cheng, V C C; Yuen, K Y; Yam, W C

    2009-08-15

    The objective of this study was to investigate the transmission history of the HIV-1 CRF01_AE epidemics in Hong Kong between 1994 and 2007. A total of 465 HIV-1 CRF01_AE pol sequences were derived from an in-house or a commercial HIV-1 genotyping system. Phylogenies of CRF01_AE sequences were analyzed by the Bayesian coalescent method. CRF01_AE patient population included 363 males (78.1%) and 102 females (21.9%), whereas 65% (314 of 465) were local Chinese. Major transmission routes were heterosexual contact (63%), followed by intravenous drug use (IDU) (19%) and men having sex with men (MSM) (17%). From phylogenetic analysis, local CRF01_AE strains were from multiple origins with 3 separate transmission clusters identified. Cluster 1 consisted mainly of Chinese male IDUs and heterosexuals. Clusters 2 and 3 included mainly local Chinese MSM and non-Chinese Asian IDUs, respectively. Chinese reference isolates available from China (Fujian, Guangxi, or Liaoning) were clonally related to our transmission clusters, demonstrating the epidemiological linkage of CRF01_AE infections between Hong Kong and China. The 3 individual local transmission clusters were estimated to have initiated since late 1980s and late 1990s, causing subsequent epidemics in the early 2000s. This is the first comprehensive molecular epidemiological study of HIV-1 CRF01_AE in Hong Kong. It revealed that MSM contact is becoming a major route of local CRF01_AE transmission in Hong Kong. Epidemiological linkage of CRF01_AE between Hong Kong and China observed in this study indicates the importance of regular molecular epidemiological surveillance for the HIV-1 epidemic in our region.

  12. The influence of laser pulse duration and energy on ICP-MS signal intensity, elemental fractionation, and particle size distribution in NIR fs-LA-ICP-MS

    Science.gov (United States)

    Diwakar, Prasoon K.; Harilal, Sivanandan S.; LaHaye, Nicole L.; Hassanein, Ahmed; Kulkarni, Pramod

    2015-01-01

    Laser parameters, typically wavelength, pulse width, irradiance, repetition rate, and pulse energy, are critical parameters which influence the laser ablation process and thereby influence the LA-ICP-MS signal. In recent times, femtosecond laser ablation has gained popularity owing to the reduction in fractionation related issues and improved analytical performance which can provide matrix-independent sampling. The advantage offered by fs-LA is due to shorter pulse duration of the laser as compared to the phonon relaxation time and heat diffusion time. Hence the thermal effects are minimized in fs-LA. Recently, fs-LA-ICP-MS demonstrated improved analytical performance as compared to ns-LA-ICP-MS, but detailed mechanisms and processes are still not clearly understood. Improvement of fs-LA-ICP-MS over ns-LA-ICP-MS elucidates the importance of laser pulse duration and related effects on the ablation process. In this study, we have investigated the influence of laser pulse width (40 fs to 0.3 ns) and energy on LA-ICP-MS signal intensity and repeatability using a brass sample. Experiments were performed in single spot ablation mode as well as rastering ablation mode to monitor the Cu/Zn ratio. The recorded ICP-MS signal was correlated with total particle counts generated during laser ablation as well as particle size distribution. Our results show the importance of pulse width effects in the fs regime that becomes more pronounced when moving from femtosecond to picosecond and nanosecond regimes. PMID:26664120

  13. Applying transpose matrix on advanced encryption standard (AES) for database content

    Science.gov (United States)

    Manurung, E. B. P.; Sitompul, O. S.; Suherman

    2018-03-01

    Advanced Encryption Standard (AES) is a specification for the encryption of electronic data established by the U.S. National Institute of Standards and Technology (NIST) and has been adopted by the U.S. government and is now used worldwide. This paper reports the impact of transpose matrix integration to AES. Transpose matrix implementation on AES is aimed at first stage of chypertext modifications for text based database security so that the confidentiality improves. The matrix is also able to increase the avalanche effect of the cryptography algorithm 4% in average.

  14. IUE observations of W UMa systems AE Phoenicis and TY Mensae

    International Nuclear Information System (INIS)

    Rucinski, S.M.

    1984-01-01

    SWP spectra of AE Phe and TY Men are presented and discussed. The spectrum of AE Phe is typical in showing strong emission lines which originate in the chromosphere and transition region. On the basis of the strenght of the He II emission line we predict that AE Phe should be a moderately strong X-ray source. The spectrum of TY Men is too weakly exposed for a full discussion. It is pointed out that this star is one of the most important for understanding the activity in W UMa systems. 18 refs., 3 figs., 1 tab. (author)

  15. Effect of postural changes on ICP in healthy and ill subjects

    DEFF Research Database (Denmark)

    Petersen, Lonnie G; Juhler, Marianne

    2015-01-01

    to distinguish normal human physiology from disease entities such as idiopathic intracranial hypertension and normal pressure hydrocephalus, we investigated ICP in different body postures in both normal and ill subjects. METHODS: Thirty-one patients were included: four normal patients following complete removal......: upright standing, sitting in a chair, supine and right lateral lumbar puncture position. RESULTS: Linear regression of median ICP based on patient posture, group, and purpose of monitoring presented a significant model (p ... of differences in median ICP between body postures and supine ICP as the baseline, presented a highly significant model (p posture (p postures enabled...

  16. Detection of multiple AE signal by triaxial hodogram analysis; Sanjiku hodogram ho ni yoru taju acoustic emission no kenshutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nagano, K; Yamashita, T [Muroran Institute of Technology, Hokkaido (Japan)

    1997-05-27

    In order to evaluate dynamic behavior of underground cracks, analysis and detection were attempted on multiple acoustic emission (AE) events. The multiple AE is a phenomenon in which multiple AE signals generated by underground cracks developed in an extremely short time interval are superimposed, and observed as one AE event. The multiple AE signal consists of two AE signals, whereas the second P-wave is supposed to have been inputted before the first S-wave is inputted. The first P-wave is inputted first, where linear three-dimensional particle movements are observed, but the movements are made random due to scattering and sensor characteristics. When the second P-wave is inputted, the linear particle movements are observed again, but are superimposed with the existing input signals and become multiple AE, which creates poor S/N ratio. The multiple AE detection determines it a multiple AE event when three conditions are met, i. e. a condition of equivalent time interval of a maximum value in a scalogram analysis, a condition of P-wave vibrating direction, and a condition of the linear particle movement. Seventy AE signals observed in the Kakkonda geothermal field were analyzed and AE signals that satisfy the multiple AE were detected. However, further development is required on an analysis method with high resolution for the time. 4 refs., 4 figs.

  17. Lead isotope measurements on aerosol samples with ICP-MS

    International Nuclear Information System (INIS)

    Widmer, C.R.; Kraehenbuehl, U.; Kramers, J.; Tobler, L.

    2000-01-01

    Size fractionated aerosols were collected with low pressure Berner impactors on a radio/TV tower 110 m above ground on a hill 10 km east of Bern at a total elevation of 1060 m asl. Two different wind sectors were chosen with the goal of assessing any differences in lead concentration and the 3 radiogenic lead isotopes (206,207,208) for east and west wind, respectively. A leaching technique was used to extract the lead quantitatively from the surface of the impaction foils. This method has been proven to be better suited for airborne particles than complete microwave digestion because it is less time consuming and contamination risk is smaller. Blank considerations played a major role in choosing all the chemicals, tubes, beakers and selecting the analytical method. Lead concentrations were determined with GF-AAS and lead isotopes with two different ICP-MS systems, one being a multicollector system. Precision of the simultaneous multicollector system was found to be at least a factor of 3 better than that of the sequentially operating ICP-MS. The small variations in isotope ratios from the two wind sectors can be distinctly seen with this enhanced precision. The observed relative difference in isotope ratios between east- and westwind was ∝0.6% for 207 Pb/ 206 Pb and ∝0.5% for 208 Pb/ 206 Pb. (orig.)

  18. Glass particles produced by laser ablation for ICP-MSmeasurements

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, J.; Liu, C.; Wen, S.; Mao, X.; Russo, R.E.

    2007-06-01

    Pulsed laser ablation (266nm) was used to generate glass particles from two sets of standard reference materials using femtosecond (150fs) and nanosecond (4ns) laser pulses with identical fluences of 50 J cm{sup -2}. Scanning electron microscopy (SEM) images of the collected particles revealed that there are more and larger agglomerations of particles produced by nanosecond laser ablation. In contrast to the earlier findings for metal alloy samples, no correlation between the concentration of major elements and the median particle size was found. When the current data on glass were compared with the metal alloy data, there were clear differences in terms of particle size, crater depth, heat affected zone, and ICP-MS response. For example, glass particles were larger than metal alloy particles, the craters in glass were less deep than craters in metal alloys, and damage to the sample was less pronounced in glass compared to metal alloys samples. The femtosecond laser generated more intense ICP-MS signals compared to nanosecond laser ablation for both types of samples, although glass sample behavior was more similar between ns and fs-laser ablation than for metals alloys.

  19. Shot peening influence on corrosion resistance of AE21 magnesium alloy.

    Science.gov (United States)

    2010-12-15

    "Evaluation of the electrochemical characteristics of the AE21 magnesium alloy is presented in the article. : The surfaces of tested alloys were treated by grinding and grinding followed by sodium bicarbonate shotpeening. : The specimens were evaluat...

  20. Fast Oblivious AES A Dedicated application of the MiniMac protocol

    DEFF Research Database (Denmark)

    Zakarias, Rasmus Winther; Damgård, Ivan Bjerre

    2015-01-01

    We present an actively secure multi-partycomputation of the Advanced Encryption Standard (AES). To the best of our knowledge it is the fastest of its kind to date. We start from an efficient actively secure evaluation of general binary circuits that was implemented by the authors of [DLT14......]. They presented an optimized implementation of the so-called MiniMac protocol [DZ13] that runs in the pre-processing model, and applied this to a binary AES circuit. In this paper we de- scribe how to dedicate the pre-processing to the structure of AES, which improves significantly the throughput and latency...... of previous actively secure implementations. We get a latency of about 6 ms and amortised time about 0.4 ms per AES block, which seems completely adequate for practical applications such as verification of 1-time passwords....

  1. XPS, AES and laser raman spectroscopy: A fingerprint for a materials surface characterisation

    International Nuclear Information System (INIS)

    Zaidi Embong

    2011-01-01

    This review briefly describes some of the techniques available for analysing surfaces and illustrates their usefulness with a few examples such as a metal and alloy. In particular, Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS) and laser Raman spectroscopy are all described as advanced surface analytical techniques. In analysing a surface, AES and XPS would normally be considered first, with AES being applied where high spatial resolution is required and XPS where chemical state information is needed. Laser Raman spectroscopy is useful for determining molecular bonding. A combination of XPS, AES and Laser Raman spectroscopy can give quantitative analysis from the top few atomic layers with a lateral spatial resolution of < 10 nm. (author)

  2. “Smart COPVs” - Continued Successful Development of JSC IR&D Acoustic Emissions (AE) SHM

    Data.gov (United States)

    National Aeronautics and Space Administration — Developed and applied promising quantitative pass/fail criteria to COPVs using acoustic emission (AE) and developed automated data analysis software. This lays the...

  3. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging

    DEFF Research Database (Denmark)

    Persson, Morten; El Ali, Henrik H.; Binderup, Tina

    2014-01-01

    64Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET...... studies in mice to evaluate the in vivo biodistribution and estimate human dosimetry of 64Cu-DOTA-AE105. MethodsFive mice received iv tail injection of 64Cu-DOTA-AE105 and were PET/CT scanned 1, 4.5 and 22h post injection. Volume-of-interest (VOI) were manually drawn on the following organs: heart, lung......Favorable dosimetry estimates together with previously reported uPAR PET data fully support human testing of 64Cu-DOTA-AE105....

  4. Auroral Electrojet (AE, AL, AO, AU) - A Global Measure of Auroral Zone Magnetic Activity

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The AE index is derived from geomagnetic variations in the horizontal component observed at selected (10-13) observatories along the auroral zone in the northern...

  5. Application of AE to evaluate deterioration of prt and harbor structures

    International Nuclear Information System (INIS)

    Matsuyama, Kimitoshi; Ishibashi, Akichika; Fujiwara, Tetsuro; Kanemoto, Yasuhiro; Hamada, Shigenori; Ohtsu, Masayasu

    1997-01-01

    The degree of concrete deterioration is normally evaluated by uniaxial compression tests of core samples taken from existing concrete structures. The uniaxial compression test can give details on concrete strength, elastic modulus and so forth. By using AE(acoustic emission) technique with uniaxial compression tests, we can get more useful information on interior failures of the core sample. The observation of AE activity was conducted during uniaxial compression tests of concrete specimens and samples. The specimens were cast with 5, 10, 15 and 20% air content. The samples were taken from 2 harbor sites in Japan. Generating behavior of AE was studied quantitatively on the basis of rate process theory. Distribution of pores in the concrete could be measured by the porosimeter. The relation between AE activity in the uniaxial compression test of core samples and concrete property is clarified.

  6. Everyone is working together to ease the pressures in A&E.

    Science.gov (United States)

    Kimber, Mark

    2015-01-27

    Nurse consultant Janet Youd, chair of the RCN Emergency Care Association, says nurses struggling to cope with unprecedented pressures in A&E departments should be awarded an extra half day's annual leave (Online News January 8).

  7. Identification of TRIM27 as a novel degradation target of herpes simplex virus 1 ICP0.

    Science.gov (United States)

    Conwell, Sara E; White, Anne E; Harper, J Wade; Knipe, David M

    2015-01-01

    The herpes simplex virus 1 (HSV-1) immediate early protein ICP0 performs many functions during infection, including transactivation of viral gene expression, suppression of innate immune responses, and modification and eviction of histones from viral chromatin. Although these functions of ICP0 have been characterized, the detailed mechanisms underlying ICP0's complex role during infection warrant further investigation. We thus undertook an unbiased proteomic approach to identifying viral and cellular proteins that interact with ICP0 in the infected cell. Cellular candidates resulting from our analysis included the ubiquitin-specific protease USP7, the transcriptional repressor TRIM27, DNA repair proteins NBN and MRE11A, regulators of apoptosis, including BIRC6, and the proteasome. We also identified two HSV-1 early proteins involved in nucleotide metabolism, UL39 and UL50, as novel candidate interactors of ICP0. Because TRIM27 was the most statistically significant cellular candidate, we investigated the relationship between TRIM27 and ICP0. We observed rapid, ICP0-dependent loss of TRIM27 during HSV-1 infection. TRIM27 protein levels were restored by disrupting the RING domain of ICP0 or by inhibiting the proteasome, arguing that TRIM27 is a novel degradation target of ICP0. A mutant ICP0 lacking E3 ligase activity interacted with endogenous TRIM27 during infection as demonstrated by reciprocal coimmunoprecipitation and supported by immunofluorescence data. Surprisingly, ICP0-null mutant virus yields decreased upon TRIM27 depletion, arguing that TRIM27 has a positive effect on infection despite being targeted for degradation. These results illustrate a complex interaction between TRIM27 and viral infection with potential positive or negative effects of TRIM27 on HSV under different infection conditions. During productive infection, a virus must simultaneously redirect multiple cellular pathways to replicate itself while evading detection by the host's defenses. To

  8. Clinical and molecular genetic features of Hb H and AE Bart's diseases in central Thai children.

    Science.gov (United States)

    Traivaree, Chanchai; Boonyawat, Boonchai; Monsereenusorn, Chalinee; Rujkijyanont, Piya; Photia, Apichat

    2018-01-01

    α-Thalassemia, one of the major thalassemia types in Thailand, is caused by either deletion or non-deletional mutation of one or both α-globin genes. Inactivation of three α-globin genes causes hemoglobin H (Hb H) disease, and the combination of Hb H disease with heterozygous hemoglobin E (Hb E) results in AE Bart's disease. This study aimed to characterize the clinical and hematological manifestations of 76 pediatric patients with Hb H and AE Bart's diseases treated at Phramongkutklao Hospital, a tertiary care center for thalassemia patients in central Thailand. Seventy-six unrelated pediatric patients, 58 patients with Hb H disease and 18 patients with AE Bart's disease, were enrolled in this study. Their clinical presentations, transfusion requirement, laboratory findings, and mutation analysis were retrospectively reviewed and analyzed. A total of 76 pediatric patients with Hb H and AE Bart's diseases who mainly lived in central Thailand were included in this study. The clinical severities of patients with non-deletional mutations were more severe than those with deletional mutations. Eighty-six percent of patients with non-deletional AE Bart's disease required more blood transfusion compared to 12.5% of patients with deletional AE Bart's disease. Non-deletional AE Bart's disease also had a history of urgent blood transfusion with the average of 6±0.9 times compared to 1±0.3 times in patients with deletional Hb H disease. The difference was statistically significant. This study revealed the differences in clinical spectrum between patients with Hb H disease and those with AE Bart's disease in central Thailand. The differentiation of α-thalassemia is essential for appropriate management of patients. The molecular diagnosis is useful for diagnostic confirmation and genotype-phenotype correlation.

  9. Complementary Metal-Oxide-Silicon (CMOS)-Memristor Hybrid Nanoelectronics for Advanced Encryption Standard (AES) Encryption

    Science.gov (United States)

    2016-04-01

    were built in-house at the SUNY Poly-technic Institute’s Center for Semiconductor Research ( CSR ); however, the initial devices for materials screening...A code that models the sweep-mode behavior of the bipolar ReRAM device that is initially in HRS. ............................................ 15...Standard (AES). AES is one of the most important encryption systems and is widely used in military and commercial systems. Based on an iterative

  10. Validation and empirical correction of MODIS AOT and AE over ocean

    Directory of Open Access Journals (Sweden)

    N. A. J. Schutgens

    2013-09-01

    Full Text Available We present a validation study of Collection 5 MODIS level 2 Aqua and Terra AOT (aerosol optical thickness and AE (Ångström exponent over ocean by comparison to coastal and island AERONET (AErosol RObotic NETwork sites for the years 2003–2009. We show that MODIS (MODerate-resolution Imaging Spectroradiometer AOT exhibits significant biases due to wind speed and cloudiness of the observed scene, while MODIS AE, although overall unbiased, exhibits less spatial contrast on global scales than the AERONET observations. The same behaviour can be seen when MODIS AOT is compared against Maritime Aerosol Network (MAN data, suggesting that the spatial coverage of our datasets does not preclude global conclusions. Thus, we develop empirical correction formulae for MODIS AOT and AE that significantly improve agreement of MODIS and AERONET observations. We show these correction formulae to be robust. Finally, we study random errors in the corrected MODIS AOT and AE and show that they mainly depend on AOT itself, although small contributions are present due to wind speed and cloud fraction in AOT random errors and due to AE and cloud fraction in AE random errors. Our analysis yields significantly higher random AOT errors than the official MODIS error estimate (0.03 + 0.05 τ, while random AE errors are smaller than might be expected. This new dataset of bias-corrected MODIS AOT and AE over ocean is intended for aerosol model validation and assimilation studies, but also has consequences as a stand-alone observational product. For instance, the corrected dataset suggests that much less fine mode aerosol is transported across the Pacific and Atlantic oceans.

  11. The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic discharges.

    Science.gov (United States)

    Eide, Per K; Bakken, André

    2011-08-22

    The monitoring of intracranial pressure (ICP) has a crucial role in the surveillance of patients with brain injury. During long-term monitoring of ICP, we have seen spontaneous shifts in baseline pressure (ICP sensor zero point), which are of technical and not physiological origin. The aim of the present study was to explore whether or not baseline pressures of ICP sensors can be affected by electrostatics discharges (ESD's), when ESD's are delivered at clinically relevant magnitudes. We performed bench-testing of a set of commercial ICP sensors. In our experimental setup, the ICP sensor was placed in a container with 0.9% NaCl solution. A test person was charged 0.5-10 kV, and then delivered ESD's to the sensor by touching a metal rod that was located in the container. The continuous pressure signals were recorded continuously before/after the ESD's, and the pressure readings were stored digitally using a computerized system A total of 57 sensors were tested, including 25 Codman ICP sensors and 32 Raumedic sensors. When charging the test person in the range 0.5-10 kV, typically ESD's in the range 0.5-5 kV peak pulse were delivered to the ICP sensor. Alterations in baseline pressure ≥ 2 mmHg was seen in 24 of 25 (96%) Codman sensors and in 17 of 32 (53%) Raumedic sensors. Lasting changes in baseline pressure > 10 mmHg that in the clinical setting would affect patient management, were seen frequently for both sensor types. The changes in baseline pressure were either characterized by sudden shifts or gradual drifts in baseline pressure. The baseline pressures of commercial solid ICP sensors can be altered by ESD's at discharge magnitudes that are clinically relevant. Shifts in baseline pressure change the ICP levels visualised to the physician on the monitor screen, and thereby reveal wrong ICP values, which likely represent a severe risk to the patient.

  12. Evaluation of the use of envelope analysis and DWT on AE signals generated from degrading shafts

    International Nuclear Information System (INIS)

    Gu, Dongsik; Kim, Jaegu; Kelimu, Tulugan; Huh, Sun-Chul; Choi, Byeong-Keun

    2012-01-01

    Vibration analysis is widely used in machinery diagnosis. Wavelet transforms and envelope analysis, which have been implemented in many applications in the condition monitoring of machinery, are applied in the development of a condition monitoring system for early detection of faults generated in several key components of machinery. Early fault detection is a very important factor in condition monitoring and a basic component for the application of condition-based maintenance (CBM) and predictive maintenance (PM). In addition, acoustic emission (AE) sensors have specific characteristics that are highly sensitive to high-frequency and low-energy signals. Therefore, the AE technique has been applied recently in studies on the early detection of failure. In this paper, AE signals caused by crack growth on a rotating shaft were captured through an AE sensor. The AE signatures were pre-processed using the proposed signal processing method, after which power spectrums were generated from the FFT results. In the power spectrum, some peaks from fault frequencies were presented. According to the results, crack growth in rotating machinery can be considered and detected using an AE sensor and the signal processing method.

  13. The use of ICP-MS and LA-ICP-MS techniques for uranium analysis in real-life swipe samples for safeguards purposes

    International Nuclear Information System (INIS)

    Pestana, Rafael C.B.; Sarkis, Jorge E.S.; Carvalho, Elita F.U.; Abreu Junior, Cassio H.

    2013-01-01

    Environmental swipe sampling for safeguards purposes is a powerful tool to detect undeclared materials and activities, and has been used by the International Atomic Energy Agency since 1997. This work describes the utilization of the inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for determining uranium isotopic ratios in a real-life swipe samples collected in a conversion plant at IPEN/CNEN, Brazil. Uncertainties were estimated by following the International Organization for Standardization - Guide to the Expression of Uncertainties in Measurement (ISO GUM), with a confidence level of 95%. The major uncertainties percentage for n( 235 U)/n( 238 U) ratio for ICP-MS was 3% and for LA-ICP-MS was 30% The values of uranium isotopic ratios obtained for each technique demonstrate the viability of these analytical techniques as an alternative tool for uranium analysis in swipe samples for safeguards purposes. (author)

  14. Celulitis por citomegalovirus

    Directory of Open Access Journals (Sweden)

    A. Ruiz Lascano

    2002-12-01

    Full Text Available Las lesiones cutáneas por citomegalovirus (CMV son infrecuentes y a menudo una manifestación tardía de una enfermedad sistémica, que generalmente anuncia un curso fatal. Comunicamos un caso de celulitis por CMV: una mujer de 70 años con trasplante renal efectuado 1 mes antes de la consulta, terapia inmunosupresora con ciclosporina A y metilprednisona. La paciente ingresó por fiebre, dolor e impotencia funcional en pierna derecha. Comprobamos la existencia de una placa de 8 por 4 cm eritematoedematosa. La tratamos con antibióticos sin mejoría, por lo que realizamos un estudio histopatológico de piel que mostró cambios citopáticos compatibles con infección por CMV. Los cultivos bacteriológicos y micológicos fueron negativos. La inmunohistoquímica específica para CMV y el estudio de reacción en cadena de la polimerasa (PCR de la biopsia de piel fueron positivas, al igual que la antigenemia. El tratamiento con ganciclovir produjo la mejoría del cuadro clínico. En la literatura revisada no hemos encontrado la celulitis como manifestación de enfermedad cutánea por CMV.

  15. Surface modification of ceramic materials induced by irradiation of high power pulsed ICP

    International Nuclear Information System (INIS)

    Ishigaki, Takamasa; Okada, Nobuhiro; Ohashi, Naoki; Haneda, Hajime

    2003-01-01

    Newly developed pulse-modulated high-power inductively coupled plasma [ICP] is expected to offer the unique physico-chemical condition, such as the increased concentration of chemically reactive species, as well as the appropriate heat flux for materials processing. Two kinds of oxide materials, titanium and zinc oxide, were placed at the downstream of Ar-H 2 ICP and irradiated in the plasma of continuous [CN] and pulse-modulated [PM] modes. The CN-ICP irradiation at the position close to the plasma tail gave rise to the thermal reduction of oxides. In the PM-ICP irradiation, the degree of thermal reduction depended on the lower power level during pulse-off time, as well as the total electric power. Irradiation in PM-ICP led to the increased formation of oxygen vacancies in titanium dioxide. In the case of zinc oxide, the UV emission efficiency was improved by PM-ICP irradiation, while the green emission became predominant by CN-ICP irradiation at the appropriate position. Induced effects in the two oxides by PM-ICP would be related to the high concentration of hydrogen radicals in the plasma. (author)

  16. Early Implementation of THAM for ICP Control: Therapeutic Hypothermia Avoidance and Reduction in Hypertonics/Hyperosmotics

    Directory of Open Access Journals (Sweden)

    F. A. Zeiler

    2014-01-01

    Full Text Available Background. Tromethamine (THAM has been demonstrated to reduce intracranial pressure (ICP. Early consideration for THAM may reduce the need for other measures for ICP control. Objective. To describe 4 cases of early THAM therapy for ICP control and highlight the potential to avoid TH and paralytics and achieve reduction in sedation and hypertonic/hyperosmotic agent requirements. Methods. We reviewed the charts of 4 patients treated with early THAM for ICP control. Results. We identified 2 patients with aneurysmal subarachnoid hemorrhage (SAH and 2 with traumatic brain injury (TBI receiving early THAM for ICP control. The mean time to initiation of THAM therapy was 1.8 days, with a mean duration of 5.3 days. In all patients, after 6 to 12 hours of THAM administration, ICP stability was achieved, with reduction in requirements for hypertonic saline and hyperosmotic agents. There was a relative reduction in mean hourly hypertonic saline requirements of 89.1%, 96.1%, 82.4%, and 97.0% for cases 1, 2, 3, and 4, respectively, comparing pre- to post-THAM administration. Mannitol, therapeutic hypothermia, and paralytics were avoided in all patients. Conclusions. Early administration of THAM for ICP control could potentially lead to the avoidance of other ICP directed therapies. Prospective studies of early THAM administration are warranted.

  17. Theoretical Investigation of Spectral-Interferences of Cadmium Isotopes in ICP-MS

    International Nuclear Information System (INIS)

    Rashad, A.M.; Rashad, A.M.

    2015-01-01

    Thermal properties of polyatomic ions which can interfere with cadmium during the analysis process using the inductively coupled plasma mass spectrometer ICP-MS are studied. Ionization energies and heats of formation, of the selected species at 0 K and 298 K of the expected reactions to occur under the effect of plasma conditions in ICP-MS, are calculated using Gaussian 03

  18. Elemental mapping of structural materials for a nuclear reactor by means of LA-ICP-MS

    Czech Academy of Sciences Publication Activity Database

    Vaculovič, T.; Warchilová, T.; Šimo, T.; Matal, O.; Otruba, V.; Mikuška, Pavel; Kanický, V.

    2012-01-01

    Roč. 27, č. 8 (2012), s. 1321-1326 ISSN 0267-9477 Institutional research plan: CEZ:AV0Z40310501 Keywords : LA- ICP -MS * ICP -OES * LiF–NaF salts Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.155, year: 2012

  19. Salpeterzuurdestructie en ICP-MS analyse van biotisch materiaal en voeding

    NARCIS (Netherlands)

    Velde-Koerts T van der; LAC

    2000-01-01

    Voor de bepaling van elementen in voeding en biotisch materiaal werd een analytische methode ontwikkeld, bestaande uit een salpeterzuurdestructie en een ICP-MS-analyse. De destructie werd geoptimaliseerd op basis van de salpeterzuurconcentratie en de destructietijd. De ICP-MS-analyse werd

  20. Synthesis and structural characterization of the ternary Zintl phases AE3Al2Pn4 and AE3Ga2Pn4 (AE=Ca, Sr, Ba, Eu; Pn=P, As)

    International Nuclear Information System (INIS)

    He, Hua; Tyson, Chauntae; Saito, Maia; Bobev, Svilen

    2012-01-01

    Ten new ternary phosphides and arsenides with empirical formulae AE 3 Al 2 Pn 4 and AE 3 Ga 2 Pn 4 (AE=Ca, Sr, Ba, Eu; Pn=P, As) have been synthesized using molten Ga, Al, and Pb fluxes. They have been structurally characterized by single-crystal and powder X-ray diffraction to form with two different structures—Ca 3 Al 2 P 4 , Sr 3 Al 2 As 4 , Eu 3 Al 2 P 4 , Eu 3 Al 2 As 4 , Ca 3 Ga 2 P 4 , Sr 3 Ga 2 P 4 , Sr 3 Ga 2 As 4 , and Eu 3 Ga 2 As 4 crystallize with the Ca 3 Al 2 As 4 structure type (space group C2/c, Z=4); Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 adopt the Na 3 Fe 2 S 4 structure type (space group Pnma, Z=4). The polyanions in both structures are made up of TrPn 4 tetrahedra, which share common corners and edges to form 2 ∞ [TrPn 2 ] 3– layers in the phases with the Ca 3 Al 2 As 4 structure, and 1 ∞ [TrPn 2 ] 3– chains in Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 with the Na 3 Fe 2 S 4 structure type. The valence electron count for all of these compounds follows the Zintl–Klemm rules. Electronic band structure calculations confirm them to be semiconductors. - Graphical abstract: AE 3 Al 2 Pn 4 and AE 3 Ga 2 Pn 4 (AE=Ca, Sr, Ba, Eu; Pn=P, As) crystallize in two different structures—Ca 3 Al 2 P 4 , Sr 3 Al 2 As 4 , Eu 3 Al 2 P 4 , Eu 3 Al 2 As 4 , Ca 3 Ga 2 P 4 , Sr 3 Ga 2 P 4 , Sr 3 Ga 2 As 4 , and Eu 3 Ga 2 As 4 , are isotypic with the previously reported Ca 3 Al 2 As 4 (space group C2/c (No. 15)), while Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 adopt a different structure known for Na 3 Fe 2 S 4 (space group Pnma (No. 62). The polyanions in both structures are made up of TrPn 4 tetrahedra, which by sharing common corners and edges, form 2 ∞ [TrPn 2 ] 3– layers in the former and 1 ∞ [TrPn 2 ] 3– chains in Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 . Highlights: ► AE 3 Ga 2 Pn 4 (AE=Ca, Sr, Ba, Eu; Pn=P, As) are new ternary pnictides. ► Ba 3 Al 2 P 4 and Ba 3 Al 2 As 4 adopt the Na 3 Fe 2 S 4 structure type. ► The Sr- and Ca-compounds crystallize with the Ca 3

  1. Determination of hafnium with the inductively coupled plasma (ICP)

    International Nuclear Information System (INIS)

    Wuensch, G.; Pose, K.

    1985-01-01

    The relative intensities of 198 hafnium lines in the Ar-ICP are listed. Spectral interference tables are given for the 9 analytically best lines, covering the range of +-60 pm around the Hf-lines. They include measured (not calculated) data of the interferent equivalent concentrations (IEC) and the critical concentration ratios (CCR) for 115 lines of all 34 possibly interfering elements. In many cases, these IEC- or CCR-data differ by 1 or 2 orders of magnitude from those calculated from intensities observed in the NBS-copper arc. Since no intense Hf-line is free from spectral interferences, examples are given for the calculation of the most suitable line for a known matrix. (orig.) [de

  2. Current role of ICP-MS in clinical toxicology and forensic toxicology: a metallic profile.

    Science.gov (United States)

    Goullé, Jean-Pierre; Saussereau, Elodie; Mahieu, Loïc; Guerbet, Michel

    2014-08-01

    As metal/metalloid exposure is inevitable owing to its omnipresence, it may exert toxicity in humans. Recent advances in metal/metalloid analysis have been made moving from flame atomic absorption spectrometry and electrothermal atomic absorption spectrometry to the multi-elemental inductively coupled plasma (ICP) techniques as ICP atomic emission spectrometry and ICP-MS. ICP-MS has now emerged as a major technique in inorganic analytical chemistry owing to its flexibility, high sensitivity and good reproducibility. This in depth review explores the ICP-MS metallic profile in human toxicology. It is now routinely used and of great importance, in clinical toxicology and forensic toxicology to explore biological matrices, specifically whole blood, plasma, urine, hair, nail, biopsy samples and tissues.

  3. Comparative study for toxic elements determination in air particulate reference material by INAA, CCT-ICP-MS, and ICP-MS

    International Nuclear Information System (INIS)

    Lim, J.M.; Lee, J.H.; Kim, K.H.; Moon, J.H.; Chung, Y.S.

    2005-01-01

    Although toxic elements are minor components in the atmospheric environment, they play a significant role as important marker for atmospheric science such as risk assessment, long-range transfer study, and source apportionment. Therefore, the techniques, which allow accurate and fast elemental analysis with a minimum pre-treatment, are very important. INAA has a main advantage of non-destruction of air particulate samples, while inductively Coupled plasma with mass spectrometry (ICP-MS) encounters the most significant difficulties in pre-treatment (digestion, fusion, and dilution) and polyatomic spectral interferences for interest toxic elements, Although INAA is still reference method, a number of factors (disadvantages of cost, complexity of the instruments, and scarcity of nuclear reactor) limit its applications. To date, the use of collision cell technology ICP-MS (CCT-ICP-MS) is recommended instead of typical ICP-MS for the analysis of the toxic elements; this is because CCT-ICP-MS technique prevents polyatomic spectral interferences despite of contamination and volatile effects. In this study, a number of toxic elements in reference material, NIST SRM 2783 (air particulate on filter media) were determined by INAA, CCT-ICP-MS, and ICP-MS. For both ICP methods, the filters were decomposed by microwave digestion with 5mL nitric acid. The analytical results by three methods were compared with certificated data; the INAA results showed the most accurate and precise data sets for all target elements among three methods. In detail, the deviation between analytical results and SRM's by INAA fell below 10% for all elements excluding As (14%), while those by CCT-ICP-MS were about 20%. For ICP-MS, the result does not agree with certificated data for several elements, because polyatomic spectral interference (due to 40 Ar 35 Cl, 40 Ar 23 Na, and 35 Cl 16 O) generate positive error of analytical result for As, Cu, and V. Based on our result, INAA is still one of the most

  4. Precise determination of Pb isotope ratios by simple double spike MC-ICP-MS technique without Tl addition

    Digital Repository Service at National Institute of Oceanography (India)

    Makishima, A.; Nath, B.N.; Nakamura, E.

    A double-spike multicollector ICP-MS (DS-MC-ICP-MS) technique for Pb isotope analysis without Tl addition is established and its analytical performance is examined in detail. This simple DS-MC-ICP-MS technique using 20 ng ml sup(-1) gave averages...

  5. Correlation between Earthquakes and AE Monitoring of Historical Buildings in Seismic Areas

    Directory of Open Access Journals (Sweden)

    Giuseppe Lacidogna

    2015-12-01

    Full Text Available In this contribution a new method for evaluating seismic risk in regional areas based on the acoustic emission (AE technique is proposed. Most earthquakes have precursors, i.e., phenomena of changes in the Earth’s physical-chemical properties that take place prior to an earthquake. Acoustic emissions in materials and earthquakes in the Earth’s crust, despite the fact that they take place on very different scales, are very similar phenomena; both are caused by a release of elastic energy from a source located in a medium. For the AE monitoring, two important constructions of Italian cultural heritage are considered: the chapel of the “Sacred Mountain of Varallo” and the “Asinelli Tower” of Bologna. They were monitored during earthquake sequences in their relative areas. By using the Grassberger-Procaccia algorithm, a statistical method of analysis was developed that detects AEs as earthquake precursors or aftershocks. Under certain conditions it was observed that AEs precede earthquakes. These considerations reinforce the idea that the AE monitoring can be considered an effective tool for earthquake risk evaluation.

  6. Comparison of GC-ICP-MS and HPLC-ICP-MS for species-specific isotope dilution analysis of tributyltin in sediment after accelerated solvent extraction

    International Nuclear Information System (INIS)

    Wahlen, Raimund; Wolff-Briche, Celine

    2003-01-01

    This study describes a direct comparison of GC and HPLC hyphenated to ICP-MS determination of tributyltin (TBT) in sediment by species-specific isotope dilution analysis (SS-IDMS). The certified reference sediment PACS-2 (NRC, Canada) and a candidate reference sediment (P-18/HIPA-1) were extracted using an accelerated solvent extraction (ASE) procedure. For comparison of GC and LC methods an older bottle of PACS-2 was used, whilst a fresh bottle was taken for demonstration of the accuracy of the methods. The data obtained show good agreement between both methods for both the PACS-2 sediment (LC-ICP-IDMS 828±87 ng g -1 TBT as Sn, GC-ICP-IDMS 848±39 ng g -1 TBT as Sn) and the P-18/ HIPA-1 sediment (LC-ICP-IDMS 78.0±9.7 ng g -1 TBT as Sn, GC-ICP-IDMS 79.2±3.8 ng g -1 TBT as Sn). The analysis by GC-ICP-IDMS offers a greater signal-to-noise ratio and hence a superior detection limit of 0.03 pg TBT as Sn, in the sediment extracts compared to HPLC-ICP-IDMS (3 pg TBT as Sn). A comparison of the uncertainties associated with both methods indicates superior precision of the GC approach. This is related to the better reproducibility of the peak integration, which affects the isotope ratio measurements used for IDMS. The accuracy of the ASE method combined with HPLC-ICP-IDMS was demonstrated during the international interlaboratory comparison P-18 organised by the Comite Consultatif pour la Quantite de Matiere (CCQM). The results obtained by GC-ICP-IDMS for a newly opened bottle of PACS-2 were 1087±77 ng g -1 Sn for DBT and 876±51 ng g -1 Sn for TBT (expanded uncertainties with a coverage factor of 2), which are in good agreement with the certified values of 1090±150 ng g -1 Sn and 980±130 ng g -1 Sn, respectively. (orig.)

  7. Integrated interpretation of AE clusters and fracture system in Hijiori HDR artificial reservoir; Hijiori koon gantai jinko choryuso no AE cluster to kiretsu system ni kansuru togoteki kaishaku

    Energy Technology Data Exchange (ETDEWEB)

    Tezuka, K [Japan Petroleum Exploration Corp., Tokyo (Japan); Niitsuma, H [Tohoku University, Sendai (Japan)

    1997-05-27

    With regard to a fracture system in the Hijiori hot dry rock artificial reservoir, an attempt was made on an interpretation which integrates different data. Major factors that characterize development and performance of an artificial reservoir are composed of a fracture system in rocks, which acts as circulating water paths, a heat exchange face and a reservoir space. The system relates not only with crack density distribution, but also with cracks activated by water pressure fracturing, cracks generating acoustic emission (AE), and cracks working as major flow paths, all of which are characterized by having respective behaviors and roles. Characteristics are shown on AE cluster distribution, crack distribution, production zone and estimated stress fields. Mutual relationship among these elements was discussed based on the Coulomb`s theory. The most important paths are characterized by distribution of slippery cracks. Directions and appearance frequencies of the slippery cracks affect strongly directionality of the paths, which are governed by distribution of the cracks (weak face) and stress field. Among the slippery cracks, cracks that generate AE are cracks that release large energy when a slip occurs. Evaluation on slippery crack distribution is important. 7 refs., 8 figs.

  8. Analyzing Permutations for AES-like Ciphers: Understanding ShiftRows

    DEFF Research Database (Denmark)

    Beierle, Christof; Jovanovic, Philipp; Lauridsen, Martin Mehl

    2015-01-01

    Designing block ciphers and hash functions in a manner that resemble the AES in many aspects has been very popular since Rijndael was adopted as the Advanced Encryption Standard. However, in sharp contrast to the MixColumns operation, the security implications of the way the state is permuted...... by the operation resembling ShiftRows has never been studied in depth. Here, we provide the first structured study of the influence of ShiftRows-like operations, or more generally, word-wise permutations, in AES-like ciphers with respect to diffusion properties and resistance towards differential- and linear...... normal form. Using a mixed-integer linear programming approach, we obtain optimal parameters for a wide range of AES-like ciphers, and show improvements on parameters for Rijndael-192, Rijndael-256, PRIMATEs-80 and Prøst-128. As a separate result, we show for specific cases of the state geometry...

  9. KOMBINASI ALGORITMA AES, RC4 DAN ELGAMAL DALAM SKEMA HYBRID UNTUK KEAMANAN DATA

    Directory of Open Access Journals (Sweden)

    Adi Widarma

    2016-01-01

    Full Text Available Pengiriman atau pertukaran data adalah hal yang sering terjadi dalam dunia teknologi informasi. Data yang dikirim kadang sering berisi data informasi yang penting bahkan sangat rahasia dan harus dijaga keamanannya. Untuk menjaga keamanan data, dapat dilakukan dengan menggunakan teknik kriptografi. Algoritma AES dan RC4 adalah salah satu dari algoritma simetri. Kelemahan dari algoritma simetri adalah proses enkripsi dan dekripsi menggunakan kunci yang sama. Untuk mengatasi tersebut dilakukan dengan menggunakan algoritma Elgamal. Algoritma Elgamal adalah termasuk algoritma asimetri. Algoritma Elgamal digunakan untuk mengamankan kunci dari algoritma AES dan RC4. Peningkatan keamanan pesan dan kunci dilakukan dengan algoritma hybrid. Algoritma hybrid dengan mengkombinasikan beberapa algoritma baik algoritma simetri maupun algortima asimetri akan menambah keamanan sehingga menjadi lebih aman dan powerful (Jain & Agrawal 2014. Penelitian ini akan dilakukan metode hybrid yaitu mengkombinasikan beberapa algoritma kriptografi dengan menggunakan algoritma Advanced Encryption Standard (AES dan RC4 untuk kerahasiaan data serta algoritma Elgamal digunakan untuk enkripsi dan dekripsi kunci.

  10. Evolution of microstructure and hardness of AE42 alloy after heat treatments

    DEFF Research Database (Denmark)

    Huang, Y.D.; Dieringa, H.; Hort, N.

    2008-01-01

    properties even further. It is shown that the microstructure of the squeeze-cast AE42 alloy is stable at high temperature 450 degrees C. The subsequent solution and ageing treatments have a limited effect on the hardness. The weak age-hardening is attributed to the precipitation of small amount Of Mg17Al12......The AE42 magnesium alloy was developed for high pressure die casting (HPDC) from low-aluminum magnesium alloys. In this alloy the rare earth (RE) elements were shown to increase creep resistance by forming AlxREy intermetallics along the grain boundaries. The present work investigates...... the microstructure of squeeze cast AE42 magnesium alloy and evaluates its hardness before and after heat treatments. The change in hardness is discussed based on the microstructural observations. Some suggestions are given concerning future design of alloy compositions in order to improve high temperature creep...

  11. The effect of CFRP on retrofitting of damaged HSRC beams using AE technique

    Science.gov (United States)

    Soffian Noor, M. S.; Noorsuhada, M. N.

    2017-12-01

    This paper presents the effect of carbon fibre reinforced polymer (CFRP) on retrofitted high strength reinforced concrete (HSRC) beams using acoustic emission (AE) technique. Two RC beam parameters were prepared. The first was the control beam which was undamaged HSRC beam. The second was the damaged HSRC beam retrofitted with CFRP on the soffit. The main objective of this study is to assess the crack modes of HSRC beams using AE signal strength. The relationship between signal strength, load and time were analysed and discussed. The crack pattern observed from the visual observation was also investigated. HSRC beam retrofitted with CFRP produced high signal strength compared to control beam. It demonstrates the effect of the AE signal strength for interpretation and prediction of failure modes that might occur in the beam specimens.

  12. Electrocardiografo por computadora

    OpenAIRE

    Tinoco Hernandez, Rosanna; Paredes Bejarano, Margarita; Romero Chaglia, Norman; Yapur Auad, Miguel Eduardo

    2009-01-01

    El presente trabajo trata sobrees el diseño y la implementación de un graficador de señales cardiacas por computadora, para lo cual diseñamos un circuito electrónico capaz de recibir la senal analógica proveniente de la actividad electrica del corazón , amplificarla, y luego convertirla en una señal digital para ser procesada por software y finalmente ser graficada, siendo posible así observar la señal cardiaca en el monitor de un computador como un tren de pulsos. Cabe destacar que par...

  13. Ultratrace analysis of {sup 129}I in sediments by ICP-MS with collision cell

    Energy Technology Data Exchange (ETDEWEB)

    Izmer, A.V.; Becker, J.S. [Research Center Juelich (Germany). Central Div. of Analytical Chemistry; Boulyga, S.F. [Mainz Univ. (Germany). Inst. for Inorganic Chemistry and Analytical Chemistry; Zoriy, M.V. [Research Center Juelich (Germany). Central Div. of Analytical Chemistry]|[Research Center Juelich (Germany). Dept. for Safety and Radiation Protection

    2004-07-01

    The aim of the work was the development of a rapid and high-sensitive analytical method using ICP-MS with hexapole collision cell (ICP-CC-MS) for the determination of low 129I+/127I+ isotope ratios in synthetic lab standards and environmental samples. A special direct sample introduction device for iodine extraction via the gas phase from solid environmental material coupled on-line to ICP-CC-QMS was developed. The detection limit for 129I+ determination in aqueous solution and soil samples via gas-phase extraction was determined to be of 0.8 pg/g and 30 pg/g, respectively. (orig.)

  14. Metal ion transport quantified by ICP-MS in intact cells

    Science.gov (United States)

    Figueroa, Julio A. Landero; Stiner, Cory A.; Radzyukevich, Tatiana L.; Heiny, Judith A.

    2016-01-01

    The use of ICP-MS to measure metal ion content in biological tissues offers a highly sensitive means to study metal-dependent physiological processes. Here we describe the application of ICP-MS to measure membrane transport of Rb and K ions by the Na,K-ATPase in mouse skeletal muscles and human red blood cells. The ICP-MS method provides greater precision and statistical power than possible with conventional tracer flux methods. The method is widely applicable to studies of other metal ion transporters and metal-dependent processes in a range of cell types and conditions. PMID:26838181

  15. Environmental radioactivity research on the Fukushima Dai-ichi Nuclear Power Plant accident by ICP-MS

    International Nuclear Information System (INIS)

    Ohno, Takeshi; Muramatsu, Yasuyuki

    2015-01-01

    Inductively coupled plasma (ICP) is characterized by high ionization efficiency for almost all elements. Recently, a triple quadrupole ICP-MS (ICP-MS/MS) has been applied to the measurements of isotope ratios for ultra-low level radioisotopes. The ICP-MS/MS features an additional quadrupole mass filter situated in front of the octopole reaction cell and quadrupole mass filter, which allows only the analyte ion to enter the cell by rejecting all the other ions. In this manuscript, we review recent studies on environmental radioactivity in Fukushima achieved by ICP-MS/MS techniques. (author)

  16. Characterization of Elements Regulating the Nuclear-to-Cytoplasmic Translocation of ICP0 in Late Herpes Simplex Virus 1 Infection.

    Science.gov (United States)

    Samrat, Subodh Kumar; Ha, Binh L; Zheng, Yi; Gu, Haidong

    2018-01-15

    Infected cell protein 0 (ICP0) of herpes simplex virus 1 (HSV-1) is an immediate early protein containing a RING-type E3 ubiquitin ligase. It targets several host factors for proteasomal degradation and subsequently activates viral expression. ICP0 has a nuclear localization sequence and functions in the nucleus early during infection. However, later in infection, ICP0 is found solely in the cytoplasm. The molecular mechanism and biological function of the ICP0 nuclear-to-cytoplasmic translocation are not well understood. In this study, we sought to characterize elements important for this translocation. We found that (i) in human embryonic lung fibroblast (HEL) cells, ICP0 C-terminal residues 741 to 775 were necessary but not sufficient for the nuclear-to-cytoplasmic translocation; (ii) the loss of ICP0 E3 ubiquitin ligase activity, which led to defective viral replication in nonpermissive cells, also caused mutant ICP0 to be retained in the nucleus of HEL cells; (iii) in permissive U2OS cells, however, ICP0 lacking E3 ligase activity was translocated to the cytoplasm at a pace faster than that of wild-type ICP0, suggesting that nuclear retention of ICP0 occurs in an ICP0 E3 ligase-dependent manner; and (iv) the ICP0 C terminus and late viral proteins cooperate in order to overcome nuclear retention and stimulate ICP0 cytoplasmic translocation. Taken together, less ICP0 nuclear retention may contribute to the permissiveness of U2OS cells to HSV-1 in the absence of functional ICP0. IMPORTANCE A distinct characteristic for eukaryotes is the compartmentalization of cell metabolic pathways, which allows greater efficiency and specificity of cellular functions. ICP0 of HSV-1 is a multifunctional viral protein that travels through different compartments as infection progresses. Its main regulatory functions are carried out in the nucleus, but it is translocated to the cytoplasm late during HSV-1 infection. To understand the biological significance of cytoplasmic ICP0 in

  17. Complementary AES and AEM of grain boundary regions in irradiated γ'-strengthened alloys

    International Nuclear Information System (INIS)

    Farrell, K.; Kishimoto, N.; Clausing, R.E.; Heatherly, L.; Lehman, G.L.

    1986-01-01

    Two microchemical analysis techniques are used to measure solute segregation at grain boundaries in two γ'-strengthened, fcc Fe-Ni-Cr alloys that display radiation-induced intergranular fracture. Scanning Auger electron spectroscopy (AES) of grain boundary fracture surfaces and analytical electron microscopy (AEM) of intact grain boundaries using energy-dispersive x-ray spectroscopy show good agreement on the nature and extent of segregation. The elements Ni, Si, Ti, and Mo are found to accumulate in G, Laves and γ' phases on the grain boundaries. Segregation of P is detected by AES. The complementary features of the two analytical techniques are discussed briefly

  18. Chemical spots on the surface of the strongly magnetic Herbig Ae star HD 101412

    DEFF Research Database (Denmark)

    Järvinen, S. P.; Hubrig, S.; Schöller, M.

    2016-01-01

    Due to the knowledge of the rotation period and the presence of a rather strong surface magnetic field, the sharp-lined young Herbig Ae star HD 101412 with a rotation period of 42 d has become one of the most well-studied targets among the Herbig Ae stars. High-resolution HARPS polarimetric spectra...... that is opposite to the behaviour of the other elements studied. Since classical Ap stars usually show a relationship between the magnetic field geometry and the distribution of element spots, we used in our magnetic field measurements different line samples belonging to the three elements with the most numerous...

  19. Uses of AES and RGA to study neutron-irradiation-enhanced segregation to internal surfaces

    International Nuclear Information System (INIS)

    Gessel, G.R.; White, C.L.

    1980-01-01

    The high flux of point defects to sinks during neutron irradiation can result in segregation of impurity or alloy additions to metals. Such segregants can be preexisting or produced by neutron-induced transmutations. This segregation is known to strongly influence swelling and mechanical properties. Over a period of years, facilities have been developed at ORNL incorporating AES and RGA to examine irradiated materials. Capabilities of this system include in situ tensile fracture at elevated temperatures under ultrahigh vacuum 10 -10 torr and helium release monitoring. AES and normal incidence inert ion sputtering are exploited to examine segregation at the fracture surface and chemical gradients near the surface

  20. Hello Darkness My Old Friend: The Fading of the Nearby TDE ASASSN-14ae

    OpenAIRE

    Brown, Jonathan S.; Shappee, Benjamin J.; Holoien, T. W. -S; Stanek, K. Z.; Kochanek, C. S.; Prieto, J. L.

    2016-01-01

    We present late-time optical spectroscopy taken with the Large Binocular Telescope's Multi-Object Double Spectrograph, an improved ASAS-SN pre-discovery non-detection, and late-time SWIFT observations of the nearby ($d=193$ Mpc, $z=0.0436$) tidal disruption event (TDE) ASASSN-14ae. Our observations span from $\\sim$20 days before to $\\sim$750 days after discovery. The proximity of ASASSN-14ae allows us to study the optical evolution of the flare and the transition to a host dominated state wit...

  1. Studies on the male sterility-fertility restoration system of AE. Kotschyi 19

    International Nuclear Information System (INIS)

    Cheng Junyuan; Sun Guoqing; Liu Luxiang; Zhao Linshu; Lu Xiuxia

    1996-01-01

    Sterile plants were obtained from the distant hybridization between Ae. Kotschyi 19 as the female parent and the Chinese Spring and T. yunnanense King as the male parent. Common wheat lines were used to testcross and backcross with the F 1 sterile plants successively. Male sterile line K-19 with Ae. Kotschyi cytoplasm and common wheat nucleus was bred. Over 10 K-19 MS lines were obtained. They are steady without monoploid. 7 restorers were obtained with the restoring ability from 88.2% to 96.9% according to the domestic method, from 116.4% to 150.4% according to the international method

  2. ICP MS selection of radiopure materials for the GERDA experiment

    Science.gov (United States)

    di Vacri, M. L.; Nisi, S.; Cattadori, C.; Janicsko, J.; Lubashevskiy, A.; Smolnikov, A.; Walter, M.

    2015-08-01

    The GERDA (GERmanium Detector Array) experiment, located in the Gran Sasso Underground Laboratory (LNGS, Italy) aims to search for neutrinoless double beta (0νββ) decay of the 76Ge isotope. Both an ultra-low radioactivity background environment and active techniques to abate the residual background are required to reach the background index (of 10-3 counts/keV kg y) at the Qββ. In order to veto and suppress those events that partially deposit energy in Ge detectors, the readout of liquid argon (LAr) scintillation light (SL) has been implemented for the second GERDA experimental Phase. A double veto system has been designed and constructed using highly radiopure materials (scintillating fibers, wavelength shifters, polymeric foils, reflective foils). This work describes the study of lead, thorium and uranium ultra-trace content, performed at the LNGS Chemistry Laboratory by High Resolution Mass Spectrometry (HR ICP MS), for the selection of all materials involved in the construction of the veto system

  3. ICP MS selection of radiopure materials for the GERDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Di Vacri, M. L., E-mail: divacrim@lngs.infn.it [INFN, Laboratori Nazionali del Gran Sasso, via G.Acitelli 22, 67100 Assergi (Italy); Dipartimento di Scienze Fisiche e Chimiche, University of L’Aquila, via Vetoio, 67100 L’Aquila (Italy); Nisi, S., E-mail: nisi@lngs.infn.it [INFN, Laboratori Nazionali del Gran Sasso, via G.Acitelli 22, 67100 Assergi (AQ) (Italy); Cattadori, C., E-mail: cattadori@lngs.infn.it [INFN Sezione di Milano Bicocca, Milano (Italy); Janicsko, J. [TUM Munich (Germany); Lubashevskiy, A. [MPIK, Heidelberg (Germany); JINR, Dubna (Russian Federation); Smolnikov, A. [MPIK, Heidelberg (Germany); Walter, M. [Physik-Institut, Universitat Zurich, 8057 Zurich (Switzerland)

    2015-08-17

    The GERDA (GERmanium Detector Array) experiment, located in the Gran Sasso Underground Laboratory (LNGS, Italy) aims to search for neutrinoless double beta (0νββ) decay of the {sup 76}Ge isotope. Both an ultra-low radioactivity background environment and active techniques to abate the residual background are required to reach the background index (of 10{sup −3} counts/keV kg y) at the Q{sub ββ}. In order to veto and suppress those events that partially deposit energy in Ge detectors, the readout of liquid argon (LAr) scintillation light (SL) has been implemented for the second GERDA experimental Phase. A double veto system has been designed and constructed using highly radiopure materials (scintillating fibers, wavelength shifters, polymeric foils, reflective foils). This work describes the study of lead, thorium and uranium ultra-trace content, performed at the LNGS Chemistry Laboratory by High Resolution Mass Spectrometry (HR ICP MS), for the selection of all materials involved in the construction of the veto system.

  4. ICP-MS measurement of natural radioactivity at LNGS

    Science.gov (United States)

    Nisi, S.; Copia, L.; Dafinei, I.; di Vacri, M. L.

    2017-10-01

    Rare events search experiments, like those dedicated to the direct evidence of dark matter or neutrinoless double beta decay, are among the most exciting challenges of modern physics. The sensitivity of such experiments is driven by the background, which depends substantially on the radiopurity of the materials used for the experimental apparatus. Cutting edge measurement techniques are needed for a fast, sensitive and efficient screening of these materials and the certification of their production. Trace element measurements of high sensitivity and quick execution are mandatory also in other fields like tracing the geographical origin of food, temporal and geographical assignment of cultural heritage or monitoring environmental radioactivity. This work is an overview of the inorganic mass spectrometry facility available at Gran Sasso National Laboratory (LNGS) for radiopure material screening and is especially focused on its ICP-MS instrumentation. Analytical methods developed to achieve lowest detection limits in different types of matrix, like metals, polymers, crystals and composite materials, are also indicated. Detection limits of 10-18gg-1 for 226Ra, 10-14gg-1 for U and Th and 10-12gg-1 for K are attained through dedicated operation conditions of the instrumentation. Details are given on the results obtained for different experiments ongoing or under construction at LNGS.

  5. Normalized power transmission between ABP and ICP in TBI.

    Science.gov (United States)

    Shahsavari, S; Hallen, T; McKelvey, T; Ritzen, C; Rydenhag, B

    2009-01-01

    A new approach to study the pulse transmission between the cerebrovascular bed and the intracranial space is presented. In the proposed approach, the normalized power transmission between ABP and ICP has got the main attention rather than the actual power transmission. Evaluating the gain of the proposed transfer function at any single frequency can reveal how the percentage of contribution of that specific frequency component has been changed through the cerebrospinal system. The gain of the new transfer function at the fundamental cardiac frequency was utilized to evaluate the state of the brain in three TBI patients. Results were assessed using the reference evaluations achieved by a novel CT scan-based scoring scheme. In all three study cases, the gain of the transfer function showed a good capability to follow the trend of the CT scores and describe the brain state. Comparing the new transfer function with the traditional one and also the index of compensatory reserve, the proposed transfer function was found more informative about the state of the brain in the patients under study.

  6. Indice por Materias

    Directory of Open Access Journals (Sweden)

    Montoya H Luz Marina

    1982-09-01

    Full Text Available Un índice es una lista de palabras o frases indicadores asociados que permite la ubicación de material al interior de un libro o una publicación, en este caso será por el nombre de la materia.

  7. The herpes viral transcription factor ICP4 forms a novel DNA recognition complex

    Science.gov (United States)

    Tunnicliffe, Richard B.; Lockhart-Cairns, Michael P.; Levy, Colin; Mould, A. Paul; Jowitt, Thomas A.; Sito, Hilary; Baldock, Clair; Sandri-Goldin, Rozanne M.

    2017-01-01

    Abstract The transcription factor ICP4 from herpes simplex virus has a central role in regulating the gene expression cascade which controls viral infection. Here we present the crystal structure of the functionally essential ICP4 DNA binding domain in complex with a segment from its own promoter, revealing a novel homo-dimeric fold. We also studied the complex in solution by small angle X-Ray scattering, nuclear magnetic resonance and surface-plasmon resonance which indicated that, in addition to the globular domain, a flanking intrinsically disordered region also recognizes DNA. Together the data provides a rationale for the bi-partite nature of the ICP4 DNA recognition consensus sequence as the globular and disordered regions bind synergistically to adjacent DNA motifs. Therefore in common with its eukaryotic host, the viral transcription factor ICP4 utilizes disordered regions to enhance the affinity and tune the specificity of DNA interactions in tandem with a globular domain. PMID:28505309

  8. ICP-oa TOFMS utilisation to determine the Gd isotopic abundance in gadolinium nitrate

    International Nuclear Information System (INIS)

    Dragomir, M.; Ohai, D.; Dumitrescu, I.; Furtuna, I.

    2010-01-01

    This paper is describes the development of a method that should permit the determination of isotope abundance of gadolinium in gadolinium nitrate, used as burnable poison at Cernavoda NPP. To determine the isotopic abundance of gadolinium the inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometer (ICP-oa TOFMS) was used. The ICP-oa TOFMS allows the elimination of noise associated with instrumental drift and instability (flicker noise). The absence of flicker noise in the ICP-oa TOFMS means that the isotope ratios can be measured up to the statistical limit of ion counting. With TOFMS, each spectrum acquired represents signals from ions extracted from the plasma during the same time interval, formed from identical plasma and sample introduction events. Therefore, the ICP-oa TOFMS, Optimass 8000, has been successfully used for isotope ratio measurements of Gd in gadolinium nitrate [Gd (NO 3 ) 3 x 6H 2 O] sample solutions. (authors)

  9. LA-ICP-MS Results: 3 Siple Dome A Glacial Age Archives, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains the results of Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) performed on an archive of the Siple Dome A ice core...

  10. The determination of long life radionuclides by means of sector field ICP mass spectrometry

    International Nuclear Information System (INIS)

    Kerl, W.; Becker, J.S.; Dietze, H.J.; Dannecker, W.

    1996-01-01

    Different analytical processes for determining long life radionuclides by means of double-focussing sector field ICP mass spectrometry are described. In determining long life radionuclides by means of ICP-MS, on the one hand the analytical problem areas are in the interference of isobaric atom or molecule ions (eg: 151 Eu + - 151 Sm + , 79 Se + - 39 Ar 40 ArH + ) and on the other hand in the high detection limits when using commercial sample introduction systems (eg: For 129 I). An online coupling of HPLC and ICP-MS was built up for the separation of isobaric atom ions and was tested for the separation of isobaric atom ions and was tested for its efficiency in the separation of lanthanides. Special sample introduction systems for ICP-MS were developed for the analysis of 129 I, by which the sensitivity of detection can be appreciably improved compared to commercial sample introduction systems. (orig.) [de

  11. ICP-MS: Analytical Method for Identification and Detection of Elemental Impurities.

    Science.gov (United States)

    Mittal, Mohini; Kumar, Kapil; Anghore, Durgadas; Rawal, Ravindra K

    2017-01-01

    Aim of this article is to review and discuss the currently used quantitative analytical method ICP-MS, which is used for quality control of pharmaceutical products. ICP-MS technique has several applications such as determination of single elements, multi element analysis in synthetic drugs, heavy metals in environmental water, trace element content of selected fertilizers and dairy manures. ICP-MS is also used for determination of toxic and essential elements in different varieties of food samples and metal pollutant present in the environment. The pharmaceuticals may generate impurities at various stages of development, transportation and storage which make them risky to be administered. Thus, it is essential that these impurities must be detected and quantified. ICP-MS plays an important function in the recognition and revealing of elemental impurities. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. C-terminal region of herpes simplex virus ICP8 protein needed for intranuclear localization

    International Nuclear Information System (INIS)

    Taylor, Travis J; Knipe, David M.

    2003-01-01

    The herpes simplex virus single-stranded DNA-binding protein, ICP8, localizes initially to structures in the nucleus called prereplicative sites. As replication proceeds, these sites mature into large globular structures called replication compartments. The details of what signals or proteins are involved in the redistribution of viral and cellular proteins within the nucleus between prereplicative sites and replication compartments are poorly understood; however, we showed previously that the dominant-negative d105 ICP8 does not localize to prereplicative sites and prevents the localization of other viral proteins to prereplicative sites (J. Virol. 74 (2000) 10122). Within the residues deleted in d105 (1083 to 1168), we identified a region between amino acid residues 1080 and 1135 that was predicted by computer models to contain two α-helices, one with considerable amphipathic nature. We used site-specific and random mutagenesis techniques to identify residues or structures within this region that are required for proper ICP8 localization within the nucleus. Proline substitutions in the predicted helix generated ICP8 molecules that did not localize to prereplicative sites and acted as dominant-negative inhibitors. Other substitutions that altered the charged residues in the predicted α-helix to alanine or leucine residues had little or no effect on ICP8 intranuclear localization. The predicted α-helix was dispensable for the interaction of ICP8 with the U L 9 origin-binding protein. We propose that this C-terminal α-helix is required for localization of ICP8 to prereplicative sites by binding viral or cellular factors that target or retain ICP8 at specific intranuclear sites

  13. Determination of Long-lived Radionuclides in the Environment using ICP-MS and AMS

    DEFF Research Database (Denmark)

    Hou, Xiaolin

    2011-01-01

    ICP-MS and AMS have been widely used for the measurement of radionuclides, especially long-lived radionculides. The new progress, major advantages of these two techniques and their major applications for measurement of important radionculides are summarized.......ICP-MS and AMS have been widely used for the measurement of radionuclides, especially long-lived radionculides. The new progress, major advantages of these two techniques and their major applications for measurement of important radionculides are summarized....

  14. Formation of titanium nitride layers on titanium metal: Results of XPS and AES investigations

    International Nuclear Information System (INIS)

    Moers, H.; Pfennig, G.; Klewe-Nebenius, H.; Penzhorn, R.D.; Sirch, M.; Willin, E.

    1988-09-01

    The reaction of titanium metal with gaseous nitrogen and ammonia at temperatures of 890 0 C leads to the formation of nitridic overlayers on the metallic substrate. The thicknesses of the overlayers increase with increasing reaction time. Under comparable conditions ammonia reacts much slower than nitrogen. XPS and AES depth profile analyses show continuous changes of the in-depth compositions of the overlayers. This can be interpreted in terms of a very irregular thickness of the overlayers, an assumption which is substantiated by local AES analyses and by the observation of a pronounced crystalline structure of the substrate after annealing pretreatment, which can give rise to locally different reaction rates. The depth profile is also influenced by the broad ranges of stability of the titanium nitride phases formed during the reaction. The quantitative analysis of the titanium/nitrogen overlayers by AES is difficult because of the overlap of titanium and nitrogen Auger peaks. In quantitative XPS analysis problems arise due to difficulties in defining Ti 2p peak areas. This work presents practical procedures for the quantitative evaluation by XPS and AES of nitridic overlayers with sufficient accuracy. (orig.) [de

  15. On using peak amplitude and rise time for AE source characterization

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    The major objective of signal analysis is to study the characteristics of the sources of emissions. ... When AE is used as a non-destructive evaluation tool, this information is extracted using a .... Hence, frequency response H (f ) of the transducer.

  16. Design and implementation of an ASIP-based cryptography processor for AES, IDEA, and MD5

    Directory of Open Access Journals (Sweden)

    Karim Shahbazi

    2017-08-01

    Full Text Available In this paper, a new 32-bit ASIP-based crypto processor for AES, IDEA, and MD5 is designed. The instruction-set consists of both general purpose and specific instructions for the above cryptographic algorithms. The proposed architecture has nine function units and two data buses. It has also two types of 32-bit instruction formats for executing Memory Reference (M.R., Register Reference (R.R., and Input/Output Reference (I/O R. instructions. The maximum achieved frequency is 166.916 MHz. The encoded output results of the encryption process of a 128-bit input block are obtained after 122, 146 and 170 clock cycles for AES-128, AES-192, and AES-256, respectively. Moreover, it takes 95 clock cycles to encrypt or decrypt a 64-bit input block by using IDEA. Finally, the MD5 hash algorithm requires 469 clock cycles to generate the coded outputs for a block of 512 bits. The performance of the proposed processor is compared to some previous and state-of-the-art implementations in terms of speed, latency, throughput, and flexibility.

  17. Key features of MIR.1200 (AES-2006) design and current stage of Leningrad NPP-2 construction

    International Nuclear Information System (INIS)

    Ivkov, Igor

    2010-01-01

    MIR.1200/AES-2006 is an abbreviated name of the evolving NPP design developed on the basis of the VVER-1000 Russian design with gross operation life of 480 reactor-years. This design is being implemented in four Units of Leningrad NPP-2 (LNPP-2. The AES-91/99 was used as reference during development of the AES-2006 design for LNPP-2; this design was implemented in two Units of Tianwan NPP (China). The main technical features of the MIR.1200/AES-2006 design include a double containment, four trains of active safety systems (4x100%, 4x50%), and special engineering measures for BDBA management (core catcher, H2 PARs, PHRS) based mainly on passive principles. The containment is described in detail, the main features in comparison with the reference NPP are outlined, the design layout principles are highlighted, the safety system structure and parameters are described. Attention is paid to the BDBA management system, hydrogen removal system, core catcher, and PHRS-SG and C-PHRS. (P.A.)

  18. Repression of HNF1α-mediated transcription by amino-terminal enhancer of split (AES)

    Energy Technology Data Exchange (ETDEWEB)

    Han, Eun Hee [Section of Structural Biology, Hormel Institute, University of Minnesota, Austin, MN 55912 (United States); Gorman, Amanda A. [Department of Molecular and Cellular Biochemistry, University of Kentucky, Lexington, KY 40536 (United States); Singh, Puja [Section of Structural Biology, Hormel Institute, University of Minnesota, Austin, MN 55912 (United States); Chi, Young-In, E-mail: ychi@hi.umn.edu [Section of Structural Biology, Hormel Institute, University of Minnesota, Austin, MN 55912 (United States)

    2015-12-04

    HNF1α (Hepatocyte Nuclear Factor 1α) is one of the master regulators in pancreatic beta-cell development and function, and the mutations in Hnf1α are the most common monogenic causes of diabetes mellitus. As a member of the POU transcription factor family, HNF1α exerts its gene regulatory function through various molecular interactions; however, there is a paucity of knowledge in their functional complex formation. In this study, we identified the Groucho protein AES (Amino-terminal Enhancer of Split) as a HNF1α-specific physical binding partner and functional repressor of HNF1α-mediated transcription, which has a direct link to glucose-stimulated insulin secretion in beta-cells that is impaired in the HNF1α mutation-driven diabetes. - Highlights: • We identified AES as a transcriptional repressor for HNF1α in pancreatic beta-cell. • AES's repressive activity was HNF1α-specific and was not observed with HNF1β. • AES interacts with the transactivation domain of HNF1α. • Small molecules can be designed or discovered to disrupt this interaction and improve insulin secretion and glucose homeostasis.

  19. Repression of HNF1α-mediated transcription by amino-terminal enhancer of split (AES)

    International Nuclear Information System (INIS)

    Han, Eun Hee; Gorman, Amanda A.; Singh, Puja; Chi, Young-In

    2015-01-01

    HNF1α (Hepatocyte Nuclear Factor 1α) is one of the master regulators in pancreatic beta-cell development and function, and the mutations in Hnf1α are the most common monogenic causes of diabetes mellitus. As a member of the POU transcription factor family, HNF1α exerts its gene regulatory function through various molecular interactions; however, there is a paucity of knowledge in their functional complex formation. In this study, we identified the Groucho protein AES (Amino-terminal Enhancer of Split) as a HNF1α-specific physical binding partner and functional repressor of HNF1α-mediated transcription, which has a direct link to glucose-stimulated insulin secretion in beta-cells that is impaired in the HNF1α mutation-driven diabetes. - Highlights: • We identified AES as a transcriptional repressor for HNF1α in pancreatic beta-cell. • AES's repressive activity was HNF1α-specific and was not observed with HNF1β. • AES interacts with the transactivation domain of HNF1α. • Small molecules can be designed or discovered to disrupt this interaction and improve insulin secretion and glucose homeostasis.

  20. Spatially and spectrally resolved 10 mu m emission in Herbig Ae/Be stars

    NARCIS (Netherlands)

    van Boekel, R; Waters, LBFM; Dominik, C; Dullemond, CP; Tielens, AGGM; de Koter, A

    We present new mid-infrared spectroscopy of the emission from warm circumstellar dust grains in the Herbig Ae stars HD 100546. HD 97048 and HD 104237, with a spatial resolution Of of approximate to0."9. We find that the emission in the UIR bands at 8.6, 11.3 and (HD 97048 only) 12.7 mum is extended

  1. KOMBINASI ALGORITMA AES, RC4 DAN ELGAMAL DALAM SKEMA HYBRID UNTUK KEAMANAN DATA

    Directory of Open Access Journals (Sweden)

    Adi Widarma

    2016-01-01

    Full Text Available Abstrak — Pengiriman atau pertukaran data adalah hal yang sering terjadi dalam dunia teknologi informasi. Data yang dikirim kadang sering berisi data informasi yang penting bahkan sangat rahasia dan harus dijaga keamanannya. Untuk menjaga keamanan data, dapat dilakukan dengan menggunakan teknik kriptografi. Algoritma AES dan RC4 adalah salah satu dari algoritma simetri. Kelemahan dari algoritma simetri adalah proses enkripsi dan dekripsi menggunakan kunci yang sama. Untuk mengatasi tersebut dilakukan dengan menggunakan algoritma Elgamal. Algoritma Elgamal adalah termasuk algoritma asimetri. Algoritma Elgamal  digunakan untuk mengamankan kunci dari algoritma AES dan RC4. Peningkatan keamanan pesan dan kunci dilakukan dengan algoritma hybrid. Algoritma hybrid dengan mengkombinasikan beberapa algoritma baik algoritma simetri maupun algortima asimetri akan menambah keamanan sehingga menjadi lebih aman dan powerful (Jain & Agrawal 2014. Penelitian ini akan dilakukan metode hybrid yaitu mengkombinasikan beberapa algoritma kriptografi dengan menggunakan algoritma Advanced Encryption Standard (AES dan RC4 untuk kerahasiaan data serta algoritma Elgamal digunakan untuk enkripsi dan dekripsi kunci. Kata Kunci :  kriptograpi, algoritma AES, RC4, Elgamal, hybrid

  2. The (related-key) impossible boomerang attack and its application to the AES block cipher

    NARCIS (Netherlands)

    Lu, J.

    2011-01-01

    The Advanced Encryption Standard (AES) is a 128-bit block cipher with a user key of 128, 192 or 256 bits, released by NIST in 2001 as the next-generation data encryption standard for use in the USA. It was adopted as an ISO international standard in 2005. Impossible differential cryptanalysis and

  3. Investigation of Participation in Adult Education in Turkey: AES Data Analysis

    Science.gov (United States)

    Dincer, N. Nergiz; Tekin-Koru, Ayca; Askar, Petek

    2016-01-01

    The aim of this study is to identify the determinants of participation in adult education in Turkey. The analysis is conducted using the Adult Education Survey (AES), conducted by TurkStat. The results indicate that economic growth in the sector of employment significantly and positively affects the odds for adult education participation. The data…

  4. Water Depletion in the Disk Atmosphere of Herbig AeBe Stars

    NARCIS (Netherlands)

    Fedele, D.; Pascucci, I.; Brittain, S.; Kamp, I.; Woitke, P.; Williams, J. P.; Dent, W. R. F.; Thi, W. -F.

    2011-01-01

    We present high-resolution (R similar to 100,000) L-band spectroscopy of 11 Herbig AeBe stars with circumstellar disks. The observations were obtained with the VLT/CRIRES to detect hot water and hydroxyl radical emission lines previously detected in disks around T Tauri stars. OH emission lines are

  5. Wireless AE Event and Environmental Monitoring for Wind Turbine Blades at Low Sampling Rates

    Science.gov (United States)

    Bouzid, Omar M.; Tian, Gui Y.; Cumanan, K.; Neasham, J.

    Integration of acoustic wireless technology in structural health monitoring (SHM) applications introduces new challenges due to requirements of high sampling rates, additional communication bandwidth, memory space, and power resources. In order to circumvent these challenges, this chapter proposes a novel solution through building a wireless SHM technique in conjunction with acoustic emission (AE) with field deployment on the structure of a wind turbine. This solution requires a low sampling rate which is lower than the Nyquist rate. In addition, features extracted from aliased AE signals instead of reconstructing the original signals on-board the wireless nodes are exploited to monitor AE events, such as wind, rain, strong hail, and bird strike in different environmental conditions in conjunction with artificial AE sources. Time feature extraction algorithm, in addition to the principal component analysis (PCA) method, is used to extract and classify the relevant information, which in turn is used to classify or recognise a testing condition that is represented by the response signals. This proposed novel technique yields a significant data reduction during the monitoring process of wind turbine blades.

  6. Implementing AES via an Actively/Covertly Secure Dishonest-Majority MPC Protocol

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Keller, Marcel; Keller, Enrique

    2012-01-01

    , but produces significant performance enhancements; the second enables us to perform bit-wise operations in characteristic two fields. As a bench mark application we present the evaluation of the AES cipher, a now standard bench marking example for multi-party computation. We need examine two different...

  7. Vertical Transmission of Zika Virus by Aedes aegypti and Ae. albopictus Mosquitoes.

    Science.gov (United States)

    Ciota, Alexander T; Bialosuknia, Sean M; Ehrbar, Dylan J; Kramer, Laura D

    2017-05-01

    To determine the potential role of vertical transmission in Zika virus expansion, we evaluated larval pools of perorally infected Aedes aegypti and Ae. albopictus adult female mosquitoes; ≈1/84 larvae tested were Zika virus-positive; and rates varied among mosquito populations. Thus, vertical transmission may play a role in Zika virus spread and maintenance.

  8. Rapid synthesis of the A-E fragment of ciguatoxin CTX3C.

    Science.gov (United States)

    Clark, J Stephen; Conroy, Joanne; Blake, Alexander J

    2007-05-24

    The A-E fragment of the marine natural product CTX3C has been prepared in an efficient manner by using a strategy in which two-directional and iterative ring-closing metathesis (RCM) reactions were employed for ring construction.

  9. Analysis by SIMS and AES of H:TiO2 electrodes

    International Nuclear Information System (INIS)

    Pena, J.L.; Farias, M.H.; Sanchez Sinencio, F.

    1981-01-01

    TiO 2 electrodes produced by heating in H 2 atmosphere have been analysed. SIMS (Secondary Ion Mass Spectroscopy) and AES (Auger Electron Spectroscopy) techniques were used in order to identify the atomic composition in the electrodes surface. (A.R.H.) [pt

  10. Infection of adult Aedes aegypti and Ae. albopictus mosquitoes with the entomopathogenic fungus Metarhizium anisopliae

    NARCIS (Netherlands)

    Scholte, E.J.; Takken, W.; Knols, B.G.J.

    2007-01-01

    This study describes a laboratory investigation on the use of the insect-pathogenic fungus Metarhizium anisopliae against adult Aedes aegypti and Ae. albopictus mosquitoes. At a dosage of 1.6 × 1010 conidia/m2, applied on material that served as a mosquito resting site, an average of 87.1 ± 2.65% of

  11. The excess infrared emission of Herbig Ae/Be stars - Disks or envelopes?

    Science.gov (United States)

    Hartmann, Lee; Kenyon, Scott J.; Calvet, Nuria

    1993-01-01

    It is suggested that the near-IR emission in many Herbig Ae/Be stars arises in surrounding dusty envelopes, rather than circumstellar disks. It is shown that disks around Ae/Be stars are likely to remain optically thick at the required accretion rates. It is proposed that the IR excesses of many Ae/Be stars originate in surrounding dust nebulae instead of circumstellar disks. It is suggested that the near-IR emission of the envelope is enhanced by the same processes that produce anomalous strong continuum emission at temperatures of about 1000 K in reflection nebulae surrounding hot stars. This near-IR emission could be due to small grains transiently heated by UV photons. The dust envelopes could be associated with the primary star or a nearby companion star. Some Ae/Be stars show evidence for the 3.3-6.3-micron emission features seen in reflection nebulae around hot stars, which lends further support to this suggestion.

  12. The anion exchanger Ae2 is required for enamel maturation in mouse teeth

    NARCIS (Netherlands)

    Lyaruu, D.M.; Bronckers, A.L.J.J.; Mulder, L.; Mardones, P.; Medina, J.F.; Kellokumpu, S.; Oude Elferink, R.P.J.; Everts, V.

    2008-01-01

    One of the mechanisms by which epithelial cells regulate intracellular pH is exchanging bicarbonate for Cl-. We tested the hypothesis that in ameloblasts the anion exchanger-2 (Ae2) is involved in pH regulation during maturation stage amelogenesis. Quantitative X-ray microprobe mineral content

  13. The anion exchanger Ae2 is required for enamel maturation in mouse teeth

    NARCIS (Netherlands)

    Lyaruu, D. M.; Bronckers, A. L. J. J.; Mulder, L.; Mardones, P.; Medina, J. F.; Kellokumpu, S.; Oude Elferink, R. P. J.; Everts, V.

    2008-01-01

    One of the mechanisms by which epithelial cells regulate intracellular pH is exchanging bicarbonate for Cl(-). We tested the hypothesis that in ameloblasts the anion exchanger-2 (Ae2) is involved in pH regulation during maturation stage amelogenesis. Quantitative X-ray microprobe mineral content

  14. Comparison between INAA and ICP-OES: analysis of Sudanese medicinal plants

    International Nuclear Information System (INIS)

    Sheikhaldin, Elsadig Abdelmoniem

    2014-07-01

    The aim of this study was to provide elemental concentrations in medicinal plants and mainly to compare the two different determination methods (INAA and ICP-OES after wet digestion) elemental analysis of 14 Sudanese medicinal plants was carried out using INAA and ICP-OES techniques. The selection of reported elements was done according to intersection of elements determined by both techniques. This intersecting element list contained Ca, K, Fe, Mn, Mg, Sr, Zn, Cu, Co, and Cr. INAA correlated well with ICP-OES measurements of the same plants as long as concentrations were sufficiently above LoQ. Correlation coefficients (R 2 ) in this case is close to 1. Generally, INAA results tended to be higher compared to ICP-OES. The performance and possible source of errors of both techniques was discussed also with respect to measurements of certified reference materials. INAA provided the advantage of having both, faster and non destructive sample preparation than ICP-OES. Therefore, INAA may be technique of choice for Ca, K, Zn, and Mg elements specifically when samples are needed for further investigations. Regarding the low concentrations e.g for Cr, Ni or Cu, ICP-OES is the superior technique over INAA due to the sufficiently low limits of determination and thus gaining more detectable results at low concentrations. (author)

  15. HSV-1 ICP0: An E3 Ubiquitin Ligase That Counteracts Host Intrinsic and Innate Immunity

    Directory of Open Access Journals (Sweden)

    Mirna Perusina Lanfranca

    2014-05-01

    Full Text Available The herpes simplex virus type 1 (HSV-1 encoded E3 ubiquitin ligase, infected cell protein 0 (ICP0, is required for efficient lytic viral replication and regulates the switch between the lytic and latent states of HSV-1. As an E3 ubiquitin ligase, ICP0 directs the proteasomal degradation of several cellular targets, allowing the virus to counteract different cellular intrinsic and innate immune responses. In this review, we will focus on how ICP0’s E3 ubiquitin ligase activity inactivates the host intrinsic defenses, such as nuclear domain 10 (ND10, SUMO, and the DNA damage response to HSV-1 infection. In addition, we will examine ICP0’s capacity to impair the activation of interferon (innate regulatory mediators that include IFI16 (IFN γ-inducible protein 16, MyD88 (myeloid differentiation factor 88, and Mal (MyD88 adaptor-like protein. We will also consider how ICP0 allows HSV-1 to evade activation of the NF-κB (nuclear factor kappa B inflammatory signaling pathway. Finally, ICP0’s paradoxical relationship with USP7 (ubiquitin specific protease 7 and its roles in intrinsic and innate immune responses to HSV-1 infection will be discussed.

  16. Protein arginine methyltransferase 1 regulates herpes simplex virus replication through ICP27 RGG-box methylation

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jungeun; Shin, Bongjin; Park, Eui-Soon; Yang, Sujeong; Choi, Seunga [Department of Microbiology, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); BK21 Bio Brain Center, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); Kang, Misun [Department of Microbiology, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); Rho, Jaerang, E-mail: jrrho@cnu.ac.kr [Department of Microbiology, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); BK21 Bio Brain Center, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of); GRAST, Chungnam National University, 220 Gung-dong, Yuseong-gu, Daejon 305-764 (Korea, Republic of)

    2010-01-01

    Protein arginine methylation is involved in viral infection and replication through the modulation of diverse cellular processes including RNA metabolism, cytokine signaling, and subcellular localization. It has been suggested previously that the protein arginine methylation of the RGG-box of ICP27 is required for herpes simplex virus type-1 (HSV-1) viral replication and gene expression in vivo. However, a cellular mediator for this process has not yet been identified. In our current study, we show that the protein arginine methyltransferase 1 (PRMT1) is a cellular mediator of the arginine methylation of ICP27 RGG-box. We generated arginine substitution mutants in this domain and examined which arginine residues are required for methylation by PRMT1. R138, R148 and R150 were found to be the major sites of this methylation but additional arginine residues serving as minor methylation sites are still required to sustain the fully methylated form of ICP27 RGG. We also demonstrate that the nuclear foci-like structure formation, SRPK interactions, and RNA-binding activity of ICP27 are modulated by the arginine methylation of the ICP27 RGG-box. Furthermore, HSV-1 replication is inhibited by hypomethylation of this domain resulting from the use of general PRMT inhibitors or arginine mutations. Our data thus suggest that the PRMT1 plays a key role as a cellular regulator of HSV-1 replication through ICP27 RGG-box methylation.

  17. Apendicitis por Paracoccidioides brasiliensis

    Directory of Open Access Journals (Sweden)

    Ana Beatriz MUÑOZ URRIBARRI

    2006-01-01

    Full Text Available La paracoccidioidomicosis es la micosis más prevalente en Sudamérica. La forma aguda afecta el sistema fagocítico mononuclear de niños y personas inmunocomprometidas. El compromiso gastrointestinal es frecuente y su patogenia implica diseminación hematógena y linfática. La linfadenomegalia abdominal causa obstrucción intestinal y abdomen agudo. En este artículo damos a conocer el caso de un niño con compromiso gastrointestinal por apendicitis. Este es el primer caso reportado de apendicitis por esta patología. (Rev Med Hered 2006;17:58-60.

  18. Corrosion testing on crude oil tankers and other product carriers by means of acoustic emission (AE)

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, Gerald [TUV Austria, Deutschstrasse 10, 1230 Wien (Austria); Tscheliesnig, Peter [TUV Austria, Deutschstrasse 10, 1230 Wien (Austria)

    2004-07-01

    In the last decades a lot of maritime disasters with crude oil tankers occurred (e.g. Exxon- Valdez, Erika, Prestige). Every accident led to extreme pollution with horrible consequences not only for the environment but also for the life of the inhabitants of the affected coasts. Although most of these accidents were caused by human errors, the material degradation of the ship hull due to corrosion played an important role. Acoustic emission (AE) is already used to detect and discriminate the stage of corrosion of structures located on land. A consortium consisting of experienced partners from the fields of ship building and classification as well as from AE testing and equipment manufacturing started to investigate the feasibility of this testing technique for its application on oil tankers. The aim of the research project funded by the European Commission is to develop an on-line corrosion monitoring technique based on a permanent installation of AE sensors as well as a spot testing technique during stops in harbors or at anchorages using mobile equipment. Since the project was started, a lot of lab tests as well as background measurements were done on different types of tankers up to a size of 35.000 dead weight tons (DWT). The gathered data were evaluated with a frequency domain based pattern recognition system and it was possible to distinguish the AE signals related to corrosion from those signals, which were emitted by the structure due to the harsh environment on sea (background noise). Together with the oncoming developments of the AE equipment and the improvement of the data base, this project will lead to an important breakthrough for the safe shipping of hazardous products like crude oil. (authors)

  19. 75 FR 70742 - AES Laurel Mountain, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2010-11-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER11-2036-000] AES Laurel Mountain, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket... proceeding of AES Laurel Mountain, LLC's application for market-based rate authority, with an accompanying...

  20. 77 FR 6471 - Bacillus thuringiensis Cry2Ae Protein in Cotton; Exemption from the Requirement of a Tolerance

    Science.gov (United States)

    2012-02-08

    ... rather provides a guide for readers regarding entities likely to be affected by this action. Other types... degradation by acid and proteases (Ref. 4). The Cry2Ae protein was rapidly digested (within 30 seconds) in SGF... shown to be rapidly digested in vitro. As previously stated, when Cry2Ae protein is used as a PIP in...

  1. 77 FR 71189 - AES Beaver Valley, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2012-11-29

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-442-000] AES Beaver Valley, LLC; Supplemental Notice That Initial Market- Based Rate Filing Includes Request for Blanket Section 204 Authorization This is a supplemental notice in the above-referenced proceeding, of AES Beaver...

  2. Production of Mucosally Transmissible SHIV Challenge Stocks from HIV-1 Circulating Recombinant Form 01_AE env Sequences.

    Directory of Open Access Journals (Sweden)

    Lawrence J Tartaglia

    2016-02-01

    Full Text Available Simian-human immunodeficiency virus (SHIV challenge stocks are critical for preclinical testing of vaccines, antibodies, and other interventions aimed to prevent HIV-1. A major unmet need for the field has been the lack of a SHIV challenge stock expressing circulating recombinant form 01_AE (CRF01_AE env sequences. We therefore sought to develop mucosally transmissible SHIV challenge stocks containing HIV-1 CRF01_AE env derived from acutely HIV-1 infected individuals from Thailand. SHIV-AE6, SHIV-AE6RM, and SHIV-AE16 contained env sequences that were >99% identical to the original HIV-1 isolate and did not require in vivo passaging. These viruses exhibited CCR5 tropism and displayed a tier 2 neutralization phenotype. These challenge stocks efficiently infected rhesus monkeys by the intrarectal route, replicated to high levels during acute infection, and established chronic viremia in a subset of animals. SHIV-AE16 was titrated for use in single, high dose as well as repetitive, low dose intrarectal challenge studies. These SHIV challenge stocks should facilitate the preclinical evaluation of vaccines, monoclonal antibodies, and other interventions targeted at preventing HIV-1 CRF01_AE infection.

  3. Application of ICP-MS and HPLC-ICP-MS for diagnosis and therapy of a severe intoxication with hexavalent chromium and inorganic arsenic.

    Science.gov (United States)

    Heitland, Peter; Blohm, Martin; Breuer, Christian; Brinkert, Florian; Achilles, Eike Gert; Pukite, Ieva; Köster, Helmut Dietrich

    2017-05-01

    ICP-MS and HPLC-ICP-MS were applied for diagnosis and therapeutic monitoring in a severe intoxication with a liquid containing hexavalent chromium (Cr(VI)) and inorganic arsenic (iAs). In this rare case a liver transplantation of was considered as the only chance of survival. We developed and applied methods for the determination of Cr(VI) in erythrocytes and total chromium (Cr) and arsenic (As) in blood, plasma, urine and liver tissue by ICP-MS. Exposure to iAs was diagnosed by determination of iAs species and their metabolites in urine by anion exchange HPLC-ICP-MS. Three days after ingestion of the liquid the total Cr concentrations were 2180 and 1070μg/L in whole blood and plasma, respectively, and 4540μg/L Cr(VI) in erythrocytes. The arsenic concentration in blood was 206μg/L. The urinary As species concentrations were <0.5, 109, 115, 154 and 126μg/L for arsenobetaine, As(III), As(V), methylarsonate (V) and dimethylarsinate (V), respectively. Total Cr and As concentrations in the explanted liver were 11.7 and 0.9mg/kg, respectively. Further analytical results of this case study are tabulated and provide valuable data for physicians and toxicologists. Copyright © 2017. Published by Elsevier GmbH.

  4. The use of ICP-MS and LA-ICP-MS techniques for uranium analysis in real-life swipe samples for safeguards purposes

    Energy Technology Data Exchange (ETDEWEB)

    Pestana, Rafael C.B.; Sarkis, Jorge E.S.; Carvalho, Elita F.U., E-mail: rcbpestana@gmail.com, E-mail: jesarkis@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Abreu Junior, Cassio H. [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)

    2013-07-01

    Environmental swipe sampling for safeguards purposes is a powerful tool to detect undeclared materials and activities, and has been used by the International Atomic Energy Agency since 1997. This work describes the utilization of the inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for determining uranium isotopic ratios in a real-life swipe samples collected in a conversion plant at IPEN/CNEN, Brazil. Uncertainties were estimated by following the International Organization for Standardization - Guide to the Expression of Uncertainties in Measurement (ISO GUM), with a confidence level of 95%. The major uncertainties percentage for n({sup 235}U)/n({sup 238}U) ratio for ICP-MS was 3% and for LA-ICP-MS was 30% The values of uranium isotopic ratios obtained for each technique demonstrate the viability of these analytical techniques as an alternative tool for uranium analysis in swipe samples for safeguards purposes. (author)

  5. Calibration and correction of LA-ICP-MS and LA-MC-ICP-MS analyses for element contents and isotopic ratios

    Directory of Open Access Journals (Sweden)

    Jie Lin

    2016-06-01

    Full Text Available LA-ICP-MS and LA-MC-ICP-MS have been the techniques of choice for achieving accurate and precise element content and isotopic ratio, the state-of-the-art technique combines the advantages of low detection limits with high spatial resolution, however, the analysis accuracy and precision are restricted by many factors, such as sensitivity drift, elemental/isotopic fractionation, matrix effects, interferences and the lack of sufficiently matrix-matched reference materials. Thus, rigorous and suitable calibration and correction methods are needed to obtain quantitative data. This review systematically summarized and evaluated the interference correction, quantitative calculation and sensitivity correction strategies in order to provide the analysts with suitable calibration and correction strategies according to the sample types and the analyzed elements. The functions and features of data reduction software ICPMSDataCal were also outlined, which can provide real-time and on-line data reduction of element content and isotopic ratios analyzed by LA-ICP-MS and LA-MC-ICP-MS.

  6. Determination of phosphorus in small amounts of protein samples by ICP-MS.

    Science.gov (United States)

    Becker, J Sabine; Boulyga, Sergei F; Pickhardt, Carola; Becker, J; Buddrus, Stefan; Przybylski, Michael

    2003-02-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.

  7. Realization and optimization of AES algorithm on the TMS320DM6446 based on DaVinci technology

    Science.gov (United States)

    Jia, Wen-bin; Xiao, Fu-hai

    2013-03-01

    The application of AES algorithm in the digital cinema system avoids video data to be illegal theft or malicious tampering, and solves its security problems. At the same time, in order to meet the requirements of the real-time, scene and transparent encryption of high-speed data streams of audio and video in the information security field, through the in-depth analysis of AES algorithm principle, based on the hardware platform of TMS320DM6446, with the software framework structure of DaVinci, this paper proposes the specific realization methods of AES algorithm in digital video system and its optimization solutions. The test results show digital movies encrypted by AES128 can not play normally, which ensures the security of digital movies. Through the comparison of the performance of AES128 algorithm before optimization and after, the correctness and validity of improved algorithm is verified.

  8. Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings -

    International Nuclear Information System (INIS)

    Chung, Min Hwa; Cho, Yong Sang; Yoon, Dong Jin; Kwon, Oh Yang

    1996-01-01

    For the condition monitoring of the journal bearing in rotating machinery, a system for their diagnosis by acoustic emission(AE) was developed. AE has been used to detect abnormal conditions in the bearing system. It was found from the field application study as well as the laboratory experiment using a simulated journal bearing system that AE RMS voltage was the most efficient parameter for the purpose of current study. Based on the above results, algorithms and judgement criteria for the diagnosis system was established. The system is composed of four parts as follows: the sensing part including AE sensor and preamplifier, the signal processing part for RMS-to-DC conversion to measure AE ms voltage, the interface part for transferring RMS voltage data into PC using A/D converter, and the software part including the graphic display of bearing conditions and the diagnosis program

  9. Detection of AE signals from a HTS tape during quenching in a solid cryogen-cooling system

    International Nuclear Information System (INIS)

    Kim, K.J.; Song, J.B.; Kim, J.H.; Lee, J.H.; Kim, H.M.; Kim, W.S.; Na, J.B.; Ko, T.K.; Lee, H.G.

    2010-01-01

    The acoustic emission (AE) technique is suitable for detecting the presence of thermal and mechanical stress in superconductors, which have adverse effects on the stability of their application systems. However, the detection of AE signals from a HTS tape in a bath of liquid cryogen (such as liquid nitrogen, LN 2 ) has not been reported because of its low signal to noise ratio due to the noise from the boiling liquid cryogen. In order to obtain the AE signals from the HTS tapes during quenching, this study carried out repetitive quench tests for YBCO coated conductor (CC) tapes in a cooling system using solid nitrogen (SN 2 ). This paper examined the performance of the AE sensor in terms of the amplitudes of the AE signals in the SN 2 cooling system.

  10. Continuous A.E. monitoring of nuclear systems: some feasibility studies now in-progress in France

    International Nuclear Information System (INIS)

    Roget, J.; Germain, J.L.

    1986-01-01

    Continuous A.E. monitoring of Nuclear systems can give some unique information about abnormal behaviour (leak appearance...) or crack initiation or propagation. Some feasibility studies have been undertaken in France in this field and this paper presents the results we have got in two cases. The study showed that an A.E. surveillance of pressurized safety valves indicates the appearance or the presence of a leak. Functioning noise is not a problem in this case. Secondly a large study have been undertaken to test the resistance of the pipe inner sleeve to thermal fatigue. An A.E. monitoring showed that it is possible to separate A.E. due to Crack extension from other signals by a location method in spite of high noise level. A.E. seems applicable for continuous monitoring. So, complementary tests are in progress to confirm and improve these results

  11. Structural, elastic, electronic, optical and thermoelectric properties of the Zintl-phase Ae3AlAs3 (Ae = Sr, Ba)

    Science.gov (United States)

    Benahmed, A.; Bouhemadou, A.; Alqarni, B.; Guechi, N.; Al-Douri, Y.; Khenata, R.; Bin-Omran, S.

    2018-05-01

    First-principles calculations were performed to investigate the structural, elastic, electronic, optical and thermoelectric properties of the Zintl-phase Ae3AlAs3 (Ae = Sr, Ba) using two complementary approaches based on density functional theory. The pseudopotential plane-wave method was used to explore the structural and elastic properties whereas the full-potential linearised augmented plane wave approach was used to study the structural, electronic, optical and thermoelectric properties. The calculated structural parameters are in good consistency with the corresponding measured ones. The single-crystal and polycrystalline elastic constants and related properties were examined in details. The electronic properties, including energy band dispersions, density of states and charge-carrier effective masses, were computed using Tran-Blaha modified Becke-Johnson functional for the exchange-correlation potential. It is found that both studied compounds are direct band gap semiconductors. Frequency-dependence of the linear optical functions were predicted for a wide photon energy range up to 15 eV. Charge carrier concentration and temperature dependences of the basic parameters of the thermoelectric properties were explored using the semi-classical Boltzmann transport model. Our calculations unveil that the studied compounds are characterised by a high thermopower for both carriers, especially the p-type conduction is more favourable.

  12. Development, optimisation, and application of ICP-SFMS methods for the measurement of isotope ratios

    International Nuclear Information System (INIS)

    Stuerup, S.

    2000-07-01

    The measurement of isotopic composition and isotope ratios in biological and environmental samples requires sensitive, precise, and accurate analytical techniques. The analytical techniques used are traditionally based on mass spectrometry, among these techniques is the ICP-SFMS technique, which became commercially available in the mid 1990s. This technique is characterised by high sensitivity, low background, and the ability to separate analyte signals from spectral interferences. These features are beneficial for the measurement of isotope ratios and enable the measurement of isotope ratios of elements, which it has not previously been possible to measure due to either spectral interferences or poor sensitivity. The overall purpose of the project was to investigate the potential of the single detector ICP-SFMS technique for the measurement of isotope ratios in biological and environmental samples. One part of the work has focused on the fundamental aspects of the ICP-SFMS technique with special emphasize on the features important to the measurement of isotope ratios, while another part has focused on the development, optimisation and application of specific methods for the measurement of isotope ratios of elements of nutritional interest and radionuclides. The fundamental aspects of the ICP-SFMS technique were investigated theoretically and experimentally by the measurement of isotope ratios applying different experimental conditions. It was demonstrated that isotope ratios could be measured reliably using ICP-SFMS by educated choice of acquisition parameters, scanning mode, mass discrimination correction, and by eliminating the influence of detector dead time. Applying the knowledge gained through the fundamental study, ICP-SFMS methods for the measurement of isotope ratios of calcium, zinc, molybdenum and iron in human samples and a method for the measurement of plutonium isotope ratios and ultratrace levels of plutonium and neptunium in environmental samples

  13. Potential topical natural repellent against Ae. aegypti, Culex sp. and Anopheles sp. mosquitoes

    Directory of Open Access Journals (Sweden)

    Dewi Nur Hodijah

    2014-08-01

    Full Text Available AbstrakLatar belakang:Minyak atsiri daun sirih diketahui mempunyai daya proteksi. Dibuatkan losion berdasarkan pengantar sediaan farmasi yang ditambahkan minyak atsiri daun nilam. Sediaan losion dipilih agar dapat menempel lebih lama di permukaan kulit. Tujuan penelitian ini untuk membandingkan daya proteksi antara losion dengan penambahan minyak nilam dan losion tanpa penambahan minyak nilam dibandingkan daya proteksi dengan DEET. Metode: Penelitian ini merupakan penelitian eksperimental laboratorium. Semua nyamuk uji berasal dari insektarium laboratorium penelitian kesehatan Loka litbang P2B2 Ciamis. Konsentrasi minyak atsiri daun sirih dalam losion adalah 4%; konsentrasi minyak nilam sebagai zat pengikat adalah 0,4%. Formula yang digunakan yaitu formula dasar yang ada pada pengantar sediaan farmasi. Uji repelensi dilakukan dengan menggunakan metoda yang direkomendasikan oleh Komisi pestisida.Hasil: Dihasilkan formulasi losion yang stabil dan masih memenuhi standar formulasi sediaan. Berdasarkan hasil, diperoleh data bahwa DEET dan losion hasil modifikasi memiliki rata-rata daya proteksi di atas 90% selama 6 jam terhadap nyamuk Ae.aegypti dan Culex sp. Kesimpulan: Penambahan minyak nilam pada losion sirih dapat meningkatkan daya proteksi terhadap hinggapan nyamuk Ae. aegypti dan Culex sp. (Health Science Indones 2014;1:44-8Kata kunci:repelen alamiah, minyak atsiri, daun sirih, daun nilam, Ae. aegypti, Culex sp.AbstractBackground: Betel leaf essential oil lotion has been known to have insect repellent properties. A lotion was made based on a pharmaceutical formula from a monograph where patchouli leaf essential oil was added. A lotion preparation was intended to enhance adherence of the formula on the surface of the skin. The purpose of this study was to compare protection percentage of lotion with patchouli oil and without patchouli oil lotion compared to DEET.Methods: This study is an experimental laboratory-based research. All mosquitoes

  14. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging

    International Nuclear Information System (INIS)

    Persson, Morten; El Ali, Henrik H.; Binderup, Tina; Pfeifer, Andreas; Madsen, Jacob; Rasmussen, Palle; Kjaer, Andreas

    2014-01-01

    64 Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET studies in mice to evaluate the in vivo biodistribution and estimate human dosimetry of 64 Cu-DOTA-AE105. Methods: Five mice received iv tail injection of 64 Cu-DOTA-AE105 and were PET/CT scanned 1, 4.5 and 22 h post injection. Volume-of-interest (VOI) were manually drawn on the following organs: heart, lung, liver, kidney, spleen, intestine, muscle, bone and bladder. The activity concentrations in the mentioned organs [%ID/g] were used for the dosimetry calculation. The %ID/g of each organ at 1, 4.5 and 22 h was scaled to human value based on a difference between organ and body weights. The scaled values were then exported to OLINDA software for computation of the human absorbed doses. The residence times as well as effective dose equivalent for male and female could be obtained for each organ. To validate this approach, of human projection using mouse data, five mice received iv tail injection of another 64 Cu-DOTA peptide-based tracer, 64 Cu-DOTA-TATE, and underwent same procedure as just described. The human dosimetry estimates were then compared with observed human dosimetry estimate recently found in a first-in-man study using 64 Cu-DOTA-TATE. Results: Human estimates of 64 Cu-DOTA-AE105 revealed the heart wall to receive the highest dose (0.0918 mSv/MBq) followed by the liver (0.0815 mSv/MBq), All other organs/tissue were estimated to receive doses in the range of 0.02–0.04 mSv/MBq. The mean effective whole-body dose of 64 Cu-DOTA-AE105 was estimated to be 0.0317 mSv/MBq. Relatively good correlation between human predicted and observed dosimetry estimates for 64 Cu-DOTA-TATE was found. Importantly, the effective whole body dose was predicted with very high

  15. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging.

    Science.gov (United States)

    Persson, Morten; El Ali, Henrik H; Binderup, Tina; Pfeifer, Andreas; Madsen, Jacob; Rasmussen, Palle; Kjaer, Andreas

    2014-03-01

    (64)Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET studies in mice to evaluate the in vivo biodistribution and estimate human dosimetry of (64)Cu-DOTA-AE105. Five mice received iv tail injection of (64)Cu-DOTA-AE105 and were PET/CT scanned 1, 4.5 and 22 h post injection. Volume-of-interest (VOI) were manually drawn on the following organs: heart, lung, liver, kidney, spleen, intestine, muscle, bone and bladder. The activity concentrations in the mentioned organs [%ID/g] were used for the dosimetry calculation. The %ID/g of each organ at 1, 4.5 and 22 h was scaled to human value based on a difference between organ and body weights. The scaled values were then exported to OLINDA software for computation of the human absorbed doses. The residence times as well as effective dose equivalent for male and female could be obtained for each organ. To validate this approach, of human projection using mouse data, five mice received iv tail injection of another (64)Cu-DOTA peptide-based tracer, (64)Cu-DOTA-TATE, and underwent same procedure as just described. The human dosimetry estimates were then compared with observed human dosimetry estimate recently found in a first-in-man study using (64)Cu-DOTA-TATE. Human estimates of (64)Cu-DOTA-AE105 revealed the heart wall to receive the highest dose (0.0918 mSv/MBq) followed by the liver (0.0815 mSv/MBq), All other organs/tissue were estimated to receive doses in the range of 0.02-0.04 mSv/MBq. The mean effective whole-body dose of (64)Cu-DOTA-AE105 was estimated to be 0.0317 mSv/MBq. Relatively good correlation between human predicted and observed dosimetry estimates for (64)Cu-DOTA-TATE was found. Importantly, the effective whole body dose was predicted with very high precision

  16. Apendicitis por Paracoccidioides brasiliensis.

    OpenAIRE

    MUÑOZ URRIBARRI, Ana Beatriz; CHAPARRO DAMMERT, Eduardo; FERRUFINO LLACH, Juan Carlos; VASQUEZ FLORES, Luciola

    2012-01-01

    La paracoccidioidomicosis es la micosis más prevalente en Sudamérica. La forma aguda afecta el sistema fagocítico mononuclear de niños y personas inmunocomprometidas. El compromiso gastrointestinal es frecuente y su patogenia implica diseminación hematógena y linfática. La linfadenomegalia abdominal causa obstrucción intestinal y abdomen agudo. En este artículo damos a conocer el caso de un niño con compromiso gastrointestinal por apendicitis. Este es el primer caso reportado de apendicitis p...

  17. Meningitis por Streptococcus suis

    OpenAIRE

    Geffner Sclarsky, D. E.; Moreno Muñoz, R.; Campillo Alpera, Mª.S.; Pardo Serrano, F.J.; Gómez Gómez, A.; Martínez-Lozano, Mª.D.

    2001-01-01

    La infección humana por Streptococcus suis (S. suis) es una zoonosis, con un riesgo ocupacional conocido y que suele presentarse como meningitis purulenta, que tiene baja mortalidad y frecuentes secuelas de hipoacusia y ataxia. Se han publicado menos de 150 casos humanos desde el informe original de hace 30 años. Hay una reconocida distribución geográfica viviendo la mayoría de los afectados en el norte de Europa y el sudeste Asiático. En España se han comunicado dos pacientes con enfermedad ...

  18. Por mil devaluados pesos

    Directory of Open Access Journals (Sweden)

    Annie Rodríguez Collázos

    2013-03-01

    Full Text Available El estudio de lo popular y lo urbano hasta ahora se ha centrado en el comportamiento y en algunas relaciones de los habitantes con su entorno. “Por mil devaluados pesos. Publicidad popular y urbana”, pretende explorar las formas de publicidad, dispersas en diferentes espacios populares y urbanos en Bogotá, identificando esquemas y formas características de sus propios códigos comunicativos; se centran en un objeto de estudio consistente en las estrategias publicitarias y los códigos comunicativos en los mensajes publicitarios populares en las subculturas de San Victorino, 7 de Agosto y Sanandresito de San José.

  19. Introducing wet aerosols into the static high sensitivity ICP (SHIP)

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, Andy; Engelhard, Carsten; Sperling, Michael; Buscher, Wolfgang [University of Muenster, Institute of Inorganic and Analytical Chemistry, Muenster (Germany)

    2007-08-15

    A demountable design of the static high sensitivity ICP (SHIP) for optical emission spectrometry is presented, and its use as an excitation source with the introduction of wet aerosols was investigated. Aerosols were produced by standard pneumatic sample introduction systems, namely a cross flow nebulizer, Meinhard nebulizer and PFA low flow nebulizer, which have been applied in conjunction with a double pass and a cyclonic spray chamber. The analytical capabilities of these sample introduction systems in combination with the SHIP system were evaluated with respect to the achieved sensitivity. It was found that a nebulizer tailored for low argon flow rates (0.3-0.5 L min{sup -1}) is best suited for the low flow plasma (SHIP). An optimization of all gas flow rates of the SHIP system with the PFA low flow nebulizer was carried out in a two-dimensional way with the signal to background ratio (SBR) and the robustness as optimization target parameters. Optimum conditions for a torch model with 1-mm injector tube were 0.25 and 0.36 L min{sup -1} for the plasma gas and the nebulizer gas, respectively. A torch model with a 2-mm injector tube was optimized to 0.4 L min{sup -1} for the plasma gas and 0.44 L min{sup -1} for the nebulizer gas. In both cases the SHIP system saves approximately 95% of the argon consumed by conventional inductively coupled plasma systems. The limits of detection were found to be in the low microgram per litre range and below for many elements, which was quite comparable to those of the conventional setup. Furthermore, the short-term stability and the wash out behaviour of the SHIP were investigated. Direct comparison with the conventional setup indicated that no remarkable memory effects were caused by the closed design of the torch. The analysis of a NIST SRM 1643e (Trace Elements in Water) with the SHIP yielded recoveries of 97-103% for 13 elements, measured simultaneously. (orig.)

  20. Determination of Pu and U by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Muramatsu, Y.; Yoshida, S. [National Inst. of Radiological Sciences, Chiba (Japan)

    2002-06-01

    In order to understand the distribution and behaviour of long-lived radionuclides in the terrestrial environment, we have developed analytical methods for {sup 238}U, {sup 232}Th and {sup 239},{sup 240}Pu and determined them in several environmental samples. ICP-MS was applied to the analyses. Concentrations of {sup 238}U and {sup 232}Th were determined in variety of soils, plants and environmental waters. The mean concentration of U and Th in 77 soils, collected several parts of Japan, were 2.3 and 7.0 ppm (dry wt). Red and yellow soils, which are mainly found in western Japan, have high concentrations of Th, suggesting the contribution from granitic rocks. Higher concentration of U in agricultural soils than forest soils suggested the possible accumulation of this element from phosphate fertilizer. The soil-to-plant transfer factors (concentration ratios between plants and soils) of U and Th were estimated from the analytical results of these nuclides in soils and in several crops. The factors for U were about 0.0005 in leaf vegetables, 0.0002 in root vegetables, 0.0001 in potatoes and 0.00001 in rice (polished). For Th, the factors were about 0.0005 in leaf vegetables, 0.0008 in root vegetables, 0.0005 in potatoes and 0.00003 in rice (polished). For the analysis of plutonium, chromatographic resin, Dowex 1x8, was examined for their applicability in the separation of Pu from the matrix elements. Sufficient decontamination factors (10{sup 4}-10{sup 5}) for many matrix elements including U, which interferes in the detection of mass 239, were obtained in both resins. Analytical results of {sup 239+240}Pu in standard reference materials (IAEA-135, -SOIL-6, -368 and -134) indicated that the accuracy of this method was satisfactory. Data on the {sup 240}Pu/{sup 239}Pu atom ratios in these reference materials, which are rare in the literature, were also obtained. Soil samples from the Marshall Islands showed a large variation of the {sup 240}Pu/{sup 239}Pu atom ratios

  1. NuSTAR and swift observations of the fast rotating magnetized white dwarf AE Aquarii

    DEFF Research Database (Denmark)

    Kitaguchi, Takao; An, Hongjun; Beloborodov, Andrei M.

    2014-01-01

    AE Aquarii is a cataclysmic variable with the fastest known rotating magnetized white dwarf (P-spin = 33.08 s). Compared to many intermediate polars, AE Aquarii shows a soft X-ray spectrum with a very low luminosity (L-X similar to 10(31) erg s(-1)). We have analyzed overlapping observations...... of this system with the NuSTAR and the Swift X-ray observatories in 2012 September. We find the 0.5-30 keV spectra to be well fitted by either an optically thin thermal plasma model with three temperatures of 0.75(-0.45)(+0.18), 2.29(-0.82)(+0.96), and 9.33(-2.18)(+6.07) keV, or an optically thin thermal plasma...

  2. Harmonization in preclinical epilepsy research: A joint AES/ILAE translational initiative.

    Science.gov (United States)

    Galanopoulou, Aristea S; French, Jacqueline A; O'Brien, Terence; Simonato, Michele

    2017-11-01

    Among the priority next steps outlined during the first translational epilepsy research workshop in London, United Kingdom (2012), jointly organized by the American Epilepsy Society (AES) and the International League Against Epilepsy (ILAE), are the harmonization of research practices used in preclinical studies and the development of infrastructure that facilitates multicenter preclinical studies. The AES/ILAE Translational Task Force of the ILAE has been pursuing initiatives that advance these goals. In this supplement, we present the first reports of the working groups of the Task Force that aim to improve practices of performing rodent video-electroencephalography (vEEG) studies in experimental controls, generate systematic reviews of preclinical research data, and develop preclinical common data elements (CDEs) for epilepsy research in animals. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  3. Implementation of T-box/T/sup -1/-box based AES design on latest xilinx fpga

    International Nuclear Information System (INIS)

    Kundi, D.E.; Aziz, A.

    2015-01-01

    This work presents an efficient implementation of the AES (Advance Encryption Standard) based on Tbox/T-1-box design for both the encryption and decryption on FPGA (Field Programmable Gate Array). The proposed architecture not only make efficient use of full capacity of dedicated 32 Kb BRAM (Block RAM) of latest Xilinx FPGAs (Virtex-5, Virtex-6 and 7 Series) but also saves considerable amount of BRAM and logical resources by using multiple accesses from single BRAM in one cycle of system clock as compared to conventional LUT (Look-Up-Table) techniques. The proposed T-box/T-1-box based AES design for both the encryption and decryption fits into just 4 BRAMs on FPGA and results in good efficiency TPS (Throughput per Slice) with less power consumption. (author)

  4. A SOPC-BASED Evaluation of AES for 2.4 GHz Wireless Network

    Science.gov (United States)

    Ken, Cai; Xiaoying, Liang

    In modern systems, data security is needed more than ever before and many cryptographic algorithms are utilized for security services. Wireless Sensor Networks (WSN) is an example of such technologies. In this paper an innovative SOPC-based approach for the security services evaluation in WSN is proposed that addresses the issues of scalability, flexible performance, and silicon efficiency for the hardware acceleration of encryption system. The design includes a Nios II processor together with custom designed modules for the Advanced Encryption Standard (AES) which has become the default choice for various security services in numerous applications. The objective of this mechanism is to present an efficient hardware realization of AES using very high speed integrated circuit hardware description language (Verilog HDL) and expand the usability for various applications. As compared to traditional customize processor design, the mechanism provides a very broad range of cost/performance points.

  5. Modified Redundancy based Technique—a New Approach to Combat Error Propagation Effect of AES

    Science.gov (United States)

    Sarkar, B.; Bhunia, C. T.; Maulik, U.

    2012-06-01

    Advanced encryption standard (AES) is a great research challenge. It has been developed to replace the data encryption standard (DES). AES suffers from a major limitation of error propagation effect. To tackle this limitation, two methods are available. One is redundancy based technique and the other one is bite based parity technique. The first one has a significant advantage of correcting any error on definite term over the second one but at the cost of higher level of overhead and hence lowering the processing speed. In this paper, a new approach based on the redundancy based technique is proposed that would certainly speed up the process of reliable encryption and hence the secured communication.

  6. AES Encryption Algorithm Optimization Based on 64-bit Processor Android Platform

    Directory of Open Access Journals (Sweden)

    ZHAO Jun

    2017-06-01

    Full Text Available Algorithm implemented on the mobile phone is different from one on PC. It requires little storage space and low power consumption. Standard AES S-box design uses look up table,and has high complexity and high power consumption,so it needs to be optimized when used in mobile phones. In our optimization AES encryption algorithm,the packet length is expanded to 256 bits,which would increase the security of our algorithm; look up table is replaced by adding the affine transformation based on inversion,which would reduce the storage space; operation is changed into 16-bit input and 64-bit output by merging the three steps,namely SubWords,ShiftRows MixColumns and AddRoundKey,which would improve the operation efficiency of the algorithm. The experimental results show that our algorithm not only can greatly enhance the encryption strength,but also maintain high computing efficiency.

  7. AEMnSb2 (AE=Sr, Ba): a new class of Dirac materials

    International Nuclear Information System (INIS)

    Farhan, M Arshad; Lee, Geunsik; Shim, Ji Hoon

    2014-01-01

    The Dirac fermions of Sb square net in AEMnSb 2 (AE=Sr, Ba) are investigated by using first-principles calculation. BaMnSb 2 contains Sb square net layers with a coincident stacking of Ba atoms, exhibiting Dirac fermion behavior. On the other hand, SrMnSb 2 has a staggered stacking of Sr atoms with distorted zig-zag chains of Sb atoms. Application of hydrostatic pressure on the latter induces a structural change from a staggered to a coincident arrangement of AE ions accompanying a transition from insulator to a metal containing Dirac fermions. The structural investigations show that the stacking type of cation and orthorhombic distortion of Sb layers are the main factors to decide the crystal symmetry of the material. We propose that the Dirac fermions can be obtained by controlling the size of cation and the volume of AEMnSb 2 compounds. (fast track communication)

  8. Safety, Dosimetry, and Tumor Detection Ability of 68Ga-NOTA-AE105

    DEFF Research Database (Denmark)

    Skovgaard Lund, Dorthe; Persson, Morten; Brandt-Larsen, Malene

    2017-01-01

    The overexpression of urokinase-type plasminogen activator receptors (uPARs) represents an established biomarker for aggressiveness in most common malignant diseases, including breast cancer (BC), prostate cancer (PC), and urinary bladder cancer (UBC), and is therefore an important target for new...... cancer therapeutic and diagnostic strategies. In this study, uPAR PET imaging using a68Ga-labeled version of the uPAR-targeting peptide (AE105) was investigated in a group of patients with BC, PC, and UBC. The aim of this first-in-human, phase I clinical trial was to investigate the safety.......Conclusion:This first-in-human, phase I clinical trial demonstrates the safe use and clinical potential of68Ga-NOTA-AE105 as a new radioligand for uPAR PET imaging in cancer patients....

  9. Electron and ion beam degradation effects in AES analysis of silicon nitride thin films

    International Nuclear Information System (INIS)

    Fransen, F.; Vanden Berghe, R.; Vlaeminck, R.; Hinoul, M.; Remmerie, J.; Maes, H.E.

    1985-01-01

    Silicon nitride films are currently investigated by AES combined with ion profiling techniques for their stoichiometry and oxygen content. During this analysis, ion beam and primary electron effects were observed. The effect of argon ion bombardment is the preferential sputtering of nitrogen, forming 'covalent' silicon at the surface layer (AES peak at 91 eV). The electron beam irradiation results in a decrease of the covalent silicon peak, either by an electron beam annealing effect in the bulk of the silicon nitride film, or by an ionization enhanced surface diffusion process of the silicon (electromigration). By the electron beam annealing, nitrogen species are liberated in the bulk of the silicon nitride film and migrate towards the surface where they react with the covalent silicon. The ionization enhanced diffusion originates from local charging of the surface, induced by the electron beam. (author)

  10. Registration of TLS and MLS Point Cloud Combining Genetic Algorithm with ICP

    Directory of Open Access Journals (Sweden)

    YAN Li

    2018-04-01

    Full Text Available Large scene point cloud can be quickly acquired by mobile laser scanning (MLS technology,which needs to be supplemented by terrestrial laser scanning (TLS point cloud because of limited field of view and occlusion.MLS and TLS point cloud are located in geodetic coordinate system and local coordinate system respectively.This paper proposes an automatic registration method combined genetic algorithm (GA and iterative closed point ICP to achieve a uniform coordinate reference frame.The local optimizer is utilized in ICP.The efficiency of ICP is higher than that of GA registration,but it depends on a initial solution.GA is a global optimizer,but it's inefficient.The combining strategy is that ICP is enabled to complete the registration when the GA tends to local search.The rough position measured by a built-in GPS of a terrestrial laser scanner is used in the GA registration to limit its optimizing search space.To improve the GA registration accuracy,a maximum registration model called normalized sum of matching scores (NSMS is presented.The results for measured data show that the NSMS model is effective,the root mean square error (RMSE of GA registration is 1~5 cm and the registration efficiency can be improved by about 50% combining GA with ICP.

  11. Quantification of pharmaceutical peptides in human plasma by LC-ICP-MS sulfur detection

    DEFF Research Database (Denmark)

    Møller, Laura Hyrup; Macherius, André; Hansen, Thomas Hesselhøj

    2016-01-01

    A method for quantification of a pharmaceutical peptide in human plasma was developed using gradient elution LC-ICP-MS. A membrane desolvation (MD) system was applied to remove organic solvents from the eluent prior to the detection as SO+ in the dynamic reaction cell (DRC) of the ICP-DRC-MS inst......A method for quantification of a pharmaceutical peptide in human plasma was developed using gradient elution LC-ICP-MS. A membrane desolvation (MD) system was applied to remove organic solvents from the eluent prior to the detection as SO+ in the dynamic reaction cell (DRC) of the ICP......-DRC-MS instrument and subsequent quantification by post-column isotope dilution (IDA). Plasma proteins were precipitated prior to analysis. Analytical figures of merit including linearity, precision, LOD, LOQ and accuracy were considered satisfactory for analysis of plasma samples. The selectivity of the developed...... method was demonstrated for five pharmaceutically relevant peptides: desmopressin, penetratin, substance P, PTH (1-34) and insulin. Preliminary experiments on an ICP-MS/MS system using oxygen to reduce the effect of organic solvents were also performed to compare sensitivity. The results of the study...

  12. The influence of room temperature on Mg isotope measurements by MC-ICP-MS.

    Science.gov (United States)

    Zhang, Xing-Chao; Zhang, An-Yu; Zhang, Zhao-Feng; Huang, Fang; Yu, Hui-Min

    2018-03-24

    We observed that the accuracy and precision of magnesium (Mg) isotope analyses could be affected if the room temperature oscillated during measurements. To achieve high quality Mg isotopic data, it is critical to evaluate how the unstable room temperature affects Mg isotope measurements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). We measured the Mg isotopes for the reference material DSM-3 using MC-ICP-MS under oscillating room temperatures in spring. For a comparison, we also measured the Mg isotopes under stable room temperatures, which was achieved by the installation of an improved temperature control system in the laboratory. The δ 26 Mg values measured under oscillating room temperatures have a larger deviation (δ 26 Mg from -0.09 to 0.08‰, with average δ 26 Mg = 0.00 ± 0.08 ‰) than those measured under a stable room temperature (δ 26 Mg from -0.03 to 0.03‰, with average δ 26 Mg = 0.00 ± 0.02 ‰) using the same MC-ICP-MS system. The room temperature variation can influence the stability of MC-ICP-MS. Therefore, it is critical to keep the room temperature stable to acquire high precise and accurate isotopic data when using MC-ICP-MS, especially when using the sample-standard bracketing (SSB) correction method. This article is protected by copyright. All rights reserved.

  13. An Efficient Side-Channel Protected AES Implementation with Arbitrary Protection Order

    OpenAIRE

    Groß, Hannes; Mangard, Stefan; Korak, Thomas

    2017-01-01

    Passive physical attacks, like power analysis, pose a serious threat to the security of digital circuits. In this work, we introduce an efficient sidechannel protected Advanced Encryption Standard (AES) hardware design that is completely scalable in terms of protection order. Therefore, we revisit the private circuits scheme of Ishai et al. [13] which is known to be vulnerable to glitches. We demonstrate how to achieve resistance against multivariate higher-order attacks in the presence of gl...

  14. AE monitoring instrumentation for high performance superconducting dipoles and quadrupoles, Phase 2

    Science.gov (United States)

    Iwasa, Y.

    1986-01-01

    In the past year and a half, attention has been focused on the development of instrumentation for on-line monitoring of high-performance superconducting dipoles and quadrupoles. This instrumentation has been completed and satisfactorily demonstrated on a prototype Fermi dipole. Conductor motion is the principal source of acoustic emission (AE) and the major cause of quenches in the dipole, except during the virgin run when other sources are also present. The motion events are mostly microslips. The middle of the magnet is most susceptible to quenches. This result agrees with the peak field location in the magnet. In the virgin state the top and bottom of the magnet appeared acoustically similar but diverged after training, possibly due to minute structural asymmetry, for example differences in clamping and welding strength; however, the results do not indicate any major structural defects. There is good correlation between quench current and AE starting current. The correlation is reasonable if mechanical disturbances are indeed responsible for quench. Based on AE cumulative history, the average frictional power dissipation in the whole dipole winding is estimated to be approx. 10 (MU)W cm(-3). We expect to implement the following in the next phase of this project: Application of room-temperature techniques to detecting structural defects in the dipole; application of the system to other dipoles and quadrupoles in the same series to compare their performances; and further investigation of AE starting current approx. quench current relationship. Work has begun on the room temperature measurements. Preliminary Stress Wave Factor measurements have been made on a model dipole casing.

  15. ECONOMIC MODEL FOR EVALUATION OF INTEGRAL COMPETITIVENESS OF AUTOMOTIVE ENTERPRISES (AE

    Directory of Open Access Journals (Sweden)

    A. F. Zubritsky

    2010-01-01

    Full Text Available The paper considers problems pertaining to evaluation of competitiveness of automotive enterprises in the field of international consignments. An economic model for determination of the integral AE competitiveness is proposed in the paper and the model permits to substitute an expert estimation in respect of some factors by their qualitative calculation on the basis of data on enterprise activity in the international consignment market.

  16. AE$\\mathrm{\\bar{g}}$IS Experiment Positron Accumulator: Optimization and Control

    CERN Document Server

    Moura, Joao Pedro

    2013-01-01

    The present document describes my 8-week work project at the AE$\\mathrm{\\bar{g}}$IS experiment. The project can be divided into three main tasks: 1. Theoretical preparation; 2. Support at the experiment; and 3. Control of the ES075-2 Power Supply. A description of these tasks is presented. Special emphasis is put on the third task and further developments are proposed.

  17. A Novel Image Cryptosystem Based on S-AES and Chaotic Map

    Directory of Open Access Journals (Sweden)

    Bai Lan

    2015-01-01

    Full Text Available This paper proposes a novel scheme based on simplified advanced encryption standard (S-AES for image encryption. Modified Arnold Map applied as diffusion technique for an image, and the key and dynamic S-box of encryption is generated by PWLCM. The goal is to balance rapidity and security of encryption. Experimental implementation has been done. This light encryption scheme shows resistance against chosen-plaintext attack and is suitable for sensor networks and IoT.

  18. Study of determination of microelements in Chinese herbal medicine by AES

    International Nuclear Information System (INIS)

    Wei Jiuning

    2002-01-01

    An AES method has been proposed for micro elements analysis in Chinese herbal medicine and the pretreatments of samples are discussed in detail. The method is proved accurate by analyzing peach leaves with the level of the national standard substance and by comparing results using different methods: the data obtained are accurate and reliable and the method can be used for determination 10 kinds of micro elements in Chinese herbal medicine

  19. NDT in inspection-repairing of boiler AE-101 of fertilizers Plant-Talara-Peru

    International Nuclear Information System (INIS)

    Torres, F.

    1988-01-01

    Experiences got from the use of NDT in inspection-repairing of boiler AE-101 of fertilizers Plant-Talara is presented after failures by pipes breakage. Applying liquid penetrant testing and visual inspection it was possible to determine the seriousness of the equipment the use of metallographic copies, ultrasonic measurements and hardness gave us an idea of the actual condition of the equipment, allowing a safe performance

  20. Biomimetic Syntheses of Callistrilones A-E via an Oxidative [3 + 2] Cycloaddition.

    Science.gov (United States)

    Guo, Yonghong; Zhang, Yuhan; Xiao, Mingxing; Xie, Zhixiang

    2018-04-16

    Concise total syntheses of callistrilones A-E have been achieved from 7 and commercially available α-phellandrene (8). The synthetic strategy, which was primarily inspired by the biogenetic hypothesis, was enabled by an oxidative [3 + 2] cycloaddition followed by a Michael addition and an intramolecular nucleophilic addition to construct the target molecules. Moreover, viminalin I was also synthesized, and its absolute configuration was unambiguously confirmed.

  1. Experience of a Brazilian A/E in seismic analysis of nuclear structures components

    International Nuclear Information System (INIS)

    Venancio Filho, F.; Leal, M.R.L.V.; Bevilacqua, L.

    1980-01-01

    The experience of Promon Engenharia S.A., a Brazilian A/E which participated in the civil and mechanical engineering projects of the first Nuclear Power Plant in Brazil, is presented. In these projects the aspects of input for seismic analysis, seismic analysis in nuclear structures founded on piles, dynamic analysis for airplane crash, and piping analysis had to be faced for the first time in the country. The solution of these problems and some case examples are presented. (Author) [pt

  2. Comparative evaluation of ICP sample introduction systems to be used in the metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS.

    Science.gov (United States)

    Klencsár, Balázs; Sánchez, Carlos; Balcaen, Lieve; Todolí, José; Lynen, Frederic; Vanhaecke, Frank

    2018-05-10

    A systematic evaluation of four different ICP sample introduction systems to be used in the context of metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS was carried out using diclofenac and its major metabolite, 4'-hydroxy-diclofenac, as model compounds. The strict requirements for GMP validation of chromatographic methods in the pharmaceutical industry were adhered to in this context. The final aim of this investigation is an extension of the applicability and validatability of HPLC-ICP-MS in the field of pharmaceutical R&D. Five different gradient programmes were tested while the baseline peak width (w b ), peak capacity (P), USP tailing factor (A s ) and USP signal-to-noise ratio (USP S/N) were determined as major indicators of the chromatographic performance and the values obtained were compared to the corresponding FDA recommendations (if applicable). Four different ICP-MS sample introductions systems were investigated involving two units typically working at higher flow rates (∼1.0 mL min -1 ) and another two systems working at lower flow rates (∼0.1 mL min -1 ). Optimal conditions with potential for applicability under GMP conditions were found at a mobile phase flow rate of 1.0 mL min -1 by using a pneumatic micro-flow LC nebulizer mounted onto a Peltier-cooled cyclonic spray chamber cooled to -1 °C for sample introduction. Under these conditions, HPLC-ICP-MS provided a chromatographic performance similar to that of HPLC with UV detection. The peak shape (USP tailing factor = 1.1-1.4) was significantly improved compared to that obtained with the Peltier-cooled Scott-type spray chamber. Two alternative sample introduction systems - a POINT ® and a High-Temperature Torch-Integrated Sample Introduction System (hTISIS) - were also tested at a flow rate of 0.1 mL min -1 using a chromatographic column with 1.0 mm ID. Although these systems allowed the peak shape to be improved compared to that obtained with

  3. An AES chip with DPA resistance using hardware-based random order execution

    International Nuclear Information System (INIS)

    Yu Bo; Li Xiangyu; Chen Cong; Sun Yihe; Wu Liji; Zhang Xiangmin

    2012-01-01

    This paper presents an AES (advanced encryption standard) chip that combats differential power analysis (DPA) side-channel attack through hardware-based random order execution. Both decryption and encryption procedures of an AES are implemented on the chip. A fine-grained dataflow architecture is proposed, which dynamically exploits intrinsic byte-level independence in the algorithm. A novel circuit called an HMF (Hold-Match-Fetch) unit is proposed for random control, which randomly sets execution orders for concurrent operations. The AES chip was manufactured in SMIC 0.18 μm technology. The average energy for encrypting one group of plain texts (128 bits secrete keys) is 19 nJ. The core area is 0.43 mm 2 . A sophisticated experimental setup was built to test the DPA resistance. Measurement-based experimental results show that one byte of a secret key cannot be disclosed from our chip under random mode after 64000 power traces were used in the DPA attack. Compared with the corresponding fixed order execution, the hardware based random order execution is improved by at least 21 times the DPA resistance. (semiconductor integrated circuits)

  4. An AES chip with DPA resistance using hardware-based random order execution

    Science.gov (United States)

    Bo, Yu; Xiangyu, Li; Cong, Chen; Yihe, Sun; Liji, Wu; Xiangmin, Zhang

    2012-06-01

    This paper presents an AES (advanced encryption standard) chip that combats differential power analysis (DPA) side-channel attack through hardware-based random order execution. Both decryption and encryption procedures of an AES are implemented on the chip. A fine-grained dataflow architecture is proposed, which dynamically exploits intrinsic byte-level independence in the algorithm. A novel circuit called an HMF (Hold-Match-Fetch) unit is proposed for random control, which randomly sets execution orders for concurrent operations. The AES chip was manufactured in SMIC 0.18 μm technology. The average energy for encrypting one group of plain texts (128 bits secrete keys) is 19 nJ. The core area is 0.43 mm2. A sophisticated experimental setup was built to test the DPA resistance. Measurement-based experimental results show that one byte of a secret key cannot be disclosed from our chip under random mode after 64000 power traces were used in the DPA attack. Compared with the corresponding fixed order execution, the hardware based random order execution is improved by at least 21 times the DPA resistance.

  5. Trigermanides AEGe{sub 3} (AE = Ca, Sr, Ba). Chemical bonding and superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, Rodrigo; Schnelle, Walter; Baranov, Alexey I.; Burkhardt, Ulrich; Bobnar, Matej; Cardoso-Gil, Raul; Schwarz, Ulrich; Grin, Yuri [Max-Planck-Institut fuer Chemische Physik Fester Stoffe, Dresden (Germany)

    2016-08-01

    The crystal structures of the trigermanides AEGe{sub 3}(tI32) (AE = Ca, Sr, Ba; space group I4/mmm, for SrGe{sub 3}: a = 7.7873(1), c = 12.0622(3) Aa) comprise Ge{sub 2} dumbbells forming layered Ge substructures which enclose embedded AE atoms. The chemical bonding analysis by application of the electron localizability approach reveals a substantial charge transfer from the AE atoms to the germanium substructure. The bonding within the dumbbells is of the covalent two-center type. A detailed analysis of SrGe{sub 3} reveals that the interaction on the bond-opposite side of the Ge{sub 2} groups is not lone pair-like - as it would be expected from the Zintl-like interpretation of the crystal structure with anionic Ge layers separated by alkaline-earth cations - but multi-center strongly polar between the Ge{sub 2} dumbbells and the adjacent metal atoms. Similar atomic interactions are present in CaGe{sub 3} and BaGe{sub 3}. The variation of the alkaline-earth metal has a merely insignificant influence on the superconducting transition temperatures in the s,p-electron compounds AEGe{sub 3}.

  6. A Study on the Fracture Behavior of Composite Laminated T-Joints Using AE

    International Nuclear Information System (INIS)

    Kim, J. H.; Sa, J. W.; Park, B. J.; Ahn, B. W.

    1999-01-01

    Quasi-static tests such as monotonic tension and loading/unloading tension were performed to investigate the bond characteristics and the failure processes for the T-joint specimens made from fiber/epoxy composite material. Two types of specimens, each consists of two components, e. g. skin and frame. were manufactured by co-curing and secondary bonding. During the monotonic tension test, AE instrument was used to predict AE signal at the initial and middle stage of the damage propagation. The damage initiation and progression were monitored optically using m (Charge Coupled Device) camera. And the internal crack front profile was examined using ultrasonic C-scan. The results indicate that the loads representing the abrupt increase of the AE signal are within the error range of 5 percent comparing to the loads shown in the load-time curve. Also it is shown that the initiation of crack occurred in the noodle region for both co cured and secondarily bonded specimen. The final failure occurred in the noodle region for the co-cured specimen. but at the skin/frame termination point for the secondarily bonded specimen. Based on the results, it was found that two kinds of specimen show different failure modes depending on the manufacturing methods

  7. AE analysis of delamination crack propagation in carbon fiber-reinforced polymer materials

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Jae; Arakawa, Kazuo [Kyushu University, kasuga (Japan); Chen, Dingding [National University of Defense Technology, Changsha (China); Han, Seung Wook; Choi, Nak Sam [Hanyang University, Seoul (Korea, Republic of)

    2015-01-15

    Delamination fracture behavior was investigated using acoustic emission (AE) analysis on carbon fiber-reinforced polymer (CFRP) samples manufactured using vacuum-assisted resin transfer molding (VARTM). CFRP plate was fabricated using unidirectional carbon fiber fabric with a lay-up of six plies [+30/-30]6 , and a Teflon film was inserted as a starter crack. Test pieces were sectioned from the inlet and vent of the mold, and packed between two rectangular epoxy plates to load using a universal testing machine. The AE signals were monitored during tensile loading using two sensors. The average tensile load of the inlet specimens was slightly larger than that of the vent specimens; however, the data exhibited significant scattering due to non-uniform resin distribution, and there was no statistically significant different between the strength of the samples sectioned from the inlet or outlet of the mold. Each of the specimens exhibited similar AE characteristics, regardless of whether they were from the inlet or vent of the mold. Four kinds of damage mechanism were observed: micro-cracking, fiber-resin matrix debonding, fiber pull-out, and fiber failure; and three stages of the crack propagation process were identified.

  8. MODIFIED AES WITH RANDOM S BOX GENERATION TO OVERCOME THE SIDE CHANNEL ASSAULTS USING CLOUD

    Directory of Open Access Journals (Sweden)

    M. Navaneetha Krishnan

    2017-01-01

    Full Text Available Development of any communication system with secure and complex cryptographic algorithms highly depends on concepts of data security which is crucial in the current technological world. The security and complexity of the cryptography algorithms need to get increased by randomization of secret keys. To overcome the issues associated to data security and for improvising it during encryption and decryption process over the encrypting device, a novel Secure Side Channel Assault Prevention (SSCAP approach has been projected which will eliminate outflow of side channel messages and also provides effective security over the encrypting device. An effective Enriched AES (E-AES encryption algorithm is proposed to reduce the side channel attack; the modified algorithm in this research shows its improvement in the Generation of Random Multiple S - Box (GRM S-Box which makes it hard to the attacks to break the text which is in encrypted form. Our novel SSCAP approach also improves the security over the original information; it widely minimizes the leakage of the side channel information. Attackers cannot easily get a clue about the proposed S-Box Generation technique. Our E-AES algorithm will be implemented in cloud environment thereby improving the cloud security. The proposed SSCAP approach is judged against the existing security based algorithms on the scale of encryption and decryption time, time taken for generating the key, and performance. The proposed work proves to outperform over all other methods used in the past.

  9. Variations of thermospheric composition according to AE-C data and CTIP modelling

    Directory of Open Access Journals (Sweden)

    H. Rishbeth

    2004-01-01

    Full Text Available Data from the Atmospheric Explorer C satellite, taken at middle and low latitudes in 1975-1978, are used to study latitudinal and month-by-month variations of thermospheric composition. The parameter used is the "compositional Ρ-parameter", related to the neutral atomic oxygen/molecular nitrogen concentration ratio. The midlatitude data show strong winter maxima of the atomic/molecular ratio, which account for the "seasonal anomaly" of the ionospheric F2-layer. When the AE-C data are compared with the empirical MSIS model and the computational CTIP ionosphere-thermosphere model, broadly similar features are found, but the AE-C data give a more molecular thermosphere than do the models, especially CTIP. In particular, CTIP badly overestimates the winter/summer change of composition, more so in the south than in the north. The semiannual variations at the equator and in southern latitudes, shown by CTIP and MSIS, appear more weakly in the AE-C data. Magnetic activity produces a more molecular thermosphere at high latitudes, and at mid-latitudes in summer. Key words. Atmospheric composition and structure (thermosphere – composition and chemistry

  10. Variations of thermospheric composition according to AE-C data and CTIP modelling

    Directory of Open Access Journals (Sweden)

    H. Rishbeth

    2004-01-01

    Full Text Available Data from the Atmospheric Explorer C satellite, taken at middle and low latitudes in 1975-1978, are used to study latitudinal and month-by-month variations of thermospheric composition. The parameter used is the "compositional Ρ-parameter", related to the neutral atomic oxygen/molecular nitrogen concentration ratio. The midlatitude data show strong winter maxima of the atomic/molecular ratio, which account for the "seasonal anomaly" of the ionospheric F2-layer. When the AE-C data are compared with the empirical MSIS model and the computational CTIP ionosphere-thermosphere model, broadly similar features are found, but the AE-C data give a more molecular thermosphere than do the models, especially CTIP. In particular, CTIP badly overestimates the winter/summer change of composition, more so in the south than in the north. The semiannual variations at the equator and in southern latitudes, shown by CTIP and MSIS, appear more weakly in the AE-C data. Magnetic activity produces a more molecular thermosphere at high latitudes, and at mid-latitudes in summer.

    Key words. Atmospheric composition and structure (thermosphere – composition and chemistry

  11. On the solar wind - magnetosphere - ionosphere coupling: AMPTE/CCE particle data and the AE indices

    International Nuclear Information System (INIS)

    Daglis, I.A.; Wilken, B.; Sarris, E.T.; Kremser, G.

    1992-01-01

    We present a statistical study of the substorm particle energization in terms of the energy density of the major magnetospheric ions (H + , O + , He ++ , He + ). The correlation between energy density during substorm expansion phase and the auroral indices (AE, AU, Al) is examined and interpreted. Most distinct result is that the ionospheric origin O + energy density correlate remarkable well with the AE index, while the solar wind origin He ++ energy density does not correlate at all with AE. Mixed origin H + and He + ions exhibit an intermediate behavior. Furthermore, the O + energy density correlates very well with the pre-onset AU index level, while there is no correlation with the pre-onset AL index. The results are interpreted as a result of solar wind. The results are interpreted as a result of solar wind - magnetosphere - ionosphere coupling through the internal magnetospheric dynamo: the ionosphere responds to the increased activity of the internal dynamo (which is due to the high solar wind input) and influences substorm dynamics by feeding the near-Earth magnetotail with energetic ionospheric ions during late growth phase and expansion phase

  12. A method for reduction of Acoustic Emission (AE) data with application in machine failure detection and diagnosis

    Science.gov (United States)

    Vicuña, Cristián Molina; Höweler, Christoph

    2017-12-01

    The use of AE in machine failure diagnosis has increased over the last years. Most AE-based failure diagnosis strategies use digital signal processing and thus require the sampling of AE signals. High sampling rates are required for this purpose (e.g. 2 MHz or higher), leading to streams of large amounts of data. This situation is aggravated if fine resolution and/or multiple sensors are required. These facts combine to produce bulky data, typically in the range of GBytes, for which sufficient storage space and efficient signal processing algorithms are required. This situation probably explains why, in practice, AE-based methods consist mostly in the calculation of scalar quantities such as RMS and Kurtosis, and the analysis of their evolution in time. While the scalar-based approach offers the advantage of maximum data reduction; it has the disadvantage that most part of the information contained in the raw AE signal is lost unrecoverably. This work presents a method offering large data reduction, while keeping the most important information conveyed by the raw AE signal, useful for failure detection and diagnosis. The proposed method consist in the construction of a synthetic, unevenly sampled signal which envelopes the AE bursts present on the raw AE signal in a triangular shape. The constructed signal - which we call TriSignal - also permits the estimation of most scalar quantities typically used for failure detection. But more importantly, it contains the information of the time of occurrence of the bursts, which is key for failure diagnosis. Lomb-Scargle normalized periodogram is used to construct the TriSignal spectrum, which reveals the frequency content of the TriSignal and provides the same information as the classic AE envelope. The paper includes application examples in planetary gearbox and low-speed rolling element bearing.

  13. Sepsis por shigella flexneri

    Directory of Open Access Journals (Sweden)

    César Cabrera C

    2005-04-01

    Full Text Available Se presenta un caso raro de sepsis por Shigella flexneri en una paciente de 45 años de edad quien estando hospitalizada para el estudio de un tumor cerebral, requirió el uso de manitol y dosis altas de corticoides; luego de ello presenta deposiciones líquidas con moco y sangre, desarrolla síndrome de respuesta inflamatoria sistémica, luego se aísla Shigella flexneri en el hemocultivo; recibió tratamiento antibiótico con ciprofloxacina. Se describen las características del caso y se comenta de acuerdo con la revisión de literatura.

  14. Portable exhausters POR-004 SKID B, POR-005 SKID C, POR-006 SKID D storage plan

    International Nuclear Information System (INIS)

    Nelson, O.D.; Keller, G.M.

    1997-01-01

    This document provides a storage plan for portable exhausters POR-004 SKID B, POR-005 SKID C, AND POR-006 SKID D. The exhausters will be stored until they are needed by the TWRS (Tank Waste Remediation Systems) Saltwell Pumping Program. The storage plan provides criteria for portable exhauster storage, periodic inspections during storage, and retrieval from storage

  15. Low Cost Design of an Advanced Encryption Standard (AES) Processor Using a New Common-Subexpression-Elimination Algorithm

    Science.gov (United States)

    Chen, Ming-Chih; Hsiao, Shen-Fu

    In this paper, we propose an area-efficient design of Advanced Encryption Standard (AES) processor by applying a new common-expression-elimination (CSE) method to the sub-functions of various transformations required in AES. The proposed method reduces the area cost of realizing the sub-functions by extracting the common factors in the bit-level XOR/AND-based sum-of-product expressions of these sub-functions using a new CSE algorithm. Cell-based implementation results show that the AES processor with our proposed CSE method has significant area improvement compared with previous designs.

  16. Epistatic roles of E2 glycoprotein mutations in adaption of chikungunya virus to Aedes albopictus and Ae. aegypti mosquitoes.

    Directory of Open Access Journals (Sweden)

    Konstantin A Tsetsarkin

    2009-08-01

    Full Text Available Between 2005 and 2007 Chikungunya virus (CHIKV caused its largest outbreak/epidemic in documented history. An unusual feature of this epidemic is the involvement of Ae. albopictus as a principal vector. Previously we have demonstrated that a single mutation E1-A226V significantly changed the ability of the virus to infect and be transmitted by this vector when expressed in the background of well characterized CHIKV strains LR2006 OPY1 and 37997. However, in the current study we demonstrate that introduction of the E1-A226V mutation into the background of an infectious clone derived from the Ag41855 strain (isolated in Uganda in 1982 does not significantly increase infectivity for Ae. albopictus. In order to elucidate the genetic determinants that affect CHIKV sensitivity to the E1-A226V mutation in Ae. albopictus, the genomes of the LR2006 OPY1 and Ag41855 strains were used for construction of chimeric viruses and viruses with a specific combination of point mutations at selected positions. Based upon the midgut infection rates of the derived viruses in Ae. albopictus and Ae. aegypti mosquitoes, a critical role of the mutations at positions E2-60 and E2-211 on vector infection was revealed. The E2-G60D mutation was an important determinant of CHIKV infectivity for both Ae. albopictus and Ae. aegypti, but only moderately modulated the effect of the E1-A226V mutation in Ae. albopictus. However, the effect of the E2-I211T mutation with respect to mosquito infections was much more specific, strongly modifying the effect of the E1-A226V mutation in Ae. albopictus. In contrast, CHIKV infectivity for Ae. aegypti was not influenced by the E2-1211T mutation. The occurrence of the E2-60G and E2-211I residues among CHIKV isolates was analyzed, revealing a high prevalence of E2-211I among strains belonging to the Eastern/Central/South African (ECSA clade. This suggests that the E2-211I might be important for adaptation of CHIKV to some particular conditions

  17. Measuring the BNF of Soybean Using 15N-Labelled Urea with Different Atom Excess (A.E. Content

    Directory of Open Access Journals (Sweden)

    A. Citraresmini

    2012-12-01

    Full Text Available The soybean is a legume which has an ability to supply its major nitrogen need by the biological nitrogen fixation (BNF process. This process is made possible by nodules formed in their roots, colonized by Rhizobium sp.bacteria. An accurate estimation of N gained by BNF is necessary to predict the increase or decrease of chemical fertilizer-N requirements to increase soybean production. Among several methods, the 15N method was used to estimate the ability of legumes to perform BNF. The study involved soybean var. Willis (W and a completely non-BNF soybean var. CV, which is termed as a standard crop. The standard crop is non-nodulated soybean, but it has the same main physiological traits with var. Willis. The aim of this study was to determine whether15N-labelled fertilizer with different %a.e. given to nodulated and non-nodulated soybean would not be of significant consequences for the calculation of N-BNF of W. The treatments applied were different rates of urea (20 kg N/ha and 100 kg N/ha combined with different atom excess percentages (%a.e.15N (2% and 10%. Thus, the combination of treatments were as follows:(1 W-ll (20 kg N; 2% a.e; (2 CV-hl (100 kg N; 2% a.e; (3 W-lh (20 kg N; 10% a.e; (4 CV-hh (100 kg N; 10% a.e; (5 CV-ll (20 kg N; 2% a.e; (6 W-hl (100 kg N; 2% a.e; (7 CV-lh (20 kg N; 10% a.e; (8 W-hh (100 kg N; 10% a.e. The result of the experiment showed that a high %a.e. with a low rate of 15N and a low %a.e. with a high rate of N should be used to study the %N-BNF of nodulated plants.

  18. Role for herpes simplex virus 1 ICP27 in the inhibition of type I interferon signaling

    International Nuclear Information System (INIS)

    Johnson, Karen E.; Song, Byeongwoon; Knipe, David M.

    2008-01-01

    Host cells respond to viral infection by many mechanisms, including the production of type I interferons which act in a paracrine and autocrine manner to induce the expression of antiviral interferon-stimulated genes (ISGs). Viruses have evolved means to inhibit interferon signaling to avoid induction of the innate immune response. Herpes simplex virus 1 (HSV-1) has several mechanisms to inhibit type I interferon production, the activities of ISGs, and the interferon signaling pathway itself. We report that the inhibition of the Jak/STAT pathway by HSV-1 requires viral gene expression and that viral immediate-early protein ICP27 plays a role in downregulating STAT-1 phosphorylation and in preventing the accumulation of STAT-1 in the nucleus. We also show that expression of ICP27 by transfection causes an inhibition of IFN-induced STAT-1 nuclear accumulation. Therefore, ICP27 is necessary and sufficient for at least some of the effects of HSV infection on STAT-1

  19. Study on Huizhou architecture of point cloud registration based on optimized ICP algorithm

    Science.gov (United States)

    Zhang, Runmei; Wu, Yulu; Zhang, Guangbin; Zhou, Wei; Tao, Yuqian

    2018-03-01

    In view of the current point cloud registration software has high hardware requirements, heavy workload and moltiple interactive definition, the source of software with better processing effect is not open, a two--step registration method based on normal vector distribution feature and coarse feature based iterative closest point (ICP) algorithm is proposed in this paper. This method combines fast point feature histogram (FPFH) algorithm, define the adjacency region of point cloud and the calculation model of the distribution of normal vectors, setting up the local coordinate system for each key point, and obtaining the transformation matrix to finish rough registration, the rough registration results of two stations are accurately registered by using the ICP algorithm. Experimental results show that, compared with the traditional ICP algorithm, the method used in this paper has obvious time and precision advantages for large amount of point clouds.

  20. Enhanced ICP for the Registration of Large-Scale 3D Environment Models: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Jianda Han

    2016-02-01

    Full Text Available One of the main applications of mobile robots is the large-scale perception of the outdoor environment. One of the main challenges of this application is fusing environmental data obtained by multiple robots, especially heterogeneous robots. This paper proposes an enhanced iterative closest point (ICP method for the fast and accurate registration of 3D environmental models. First, a hierarchical searching scheme is combined with the octree-based ICP algorithm. Second, an early-warning mechanism is used to perceive the local minimum problem. Third, a heuristic escape scheme based on sampled potential transformation vectors is used to avoid local minima and achieve optimal registration. Experiments involving one unmanned aerial vehicle and one unmanned surface vehicle were conducted to verify the proposed technique. The experimental results were compared with those of normal ICP registration algorithms to demonstrate the superior performance of the proposed method.

  1. Plutonium bioassay by inductively coupled plasma mass spectrometry ICP/MS

    International Nuclear Information System (INIS)

    Wyse, E.J.; Fisher, D.R.

    1993-04-01

    The determination of plutonium in urine poses several analytical challenges, e.g., detectability, matrix, etc. We have investigated the feasibility of analyzing plutonium in processed urine by inductively coupled plasma mass spectrometry (ICP/MS). The urine samples are first spiked with 244 Pu as a tracer and internal standard, then processed by co-precipitation and column chromatography using TRU-Spec trademark, an extraction resin. By enhancing ICP/MS detection capabilities via improved sample introduction and data acquisition efficiencies, an instrumental detection limit of 5 to 50 fg (0.3 to 3 fCi for 239 pu) is typically obtained, depending on the desired degree of quantitation. A brief summary of the analytical method as well as the basis for measuring radionuclides by ICP/MS are submitted; the separation procedure, methods of sample introduction, and data acquisition techniques are then highlighted

  2. A New Multielement Method for LA-ICP-MS Data Acquisition from Glacier Ice Cores.

    Science.gov (United States)

    Spaulding, Nicole E; Sneed, Sharon B; Handley, Michael J; Bohleber, Pascal; Kurbatov, Andrei V; Pearce, Nicholas J; Erhardt, Tobias; Mayewski, Paul A

    2017-11-21

    To answer pressing new research questions about the rate and timing of abrupt climate transitions, a robust system for ultrahigh-resolution sampling of glacier ice is needed. Here, we present a multielement method of LA-ICP-MS analysis wherein an array of chemical elements is simultaneously measured from the same ablation area. Although multielement techniques are commonplace for high-concentration materials, prior to the development of this method, all LA-ICP-MS analyses of glacier ice involved a single element per ablation pass or spot. This new method, developed using the LA-ICP-MS system at the W. M. Keck Laser Ice Facility at the University of Maine Climate Change Institute, has already been used to shed light on our flawed understanding of natural levels of Pb in Earth's atmosphere.

  3. Breaking through the uncertainty ceiling in LA-ICP-MS U-Pb geochronology

    Science.gov (United States)

    Horstwood, M.

    2016-12-01

    Sources of systematic uncertainty associated with session-to-session bias are the dominant contributor to the 2% (2s) uncertainty ceiling that currently limits the accuracy of LA-ICP-MS U-Pb geochronology. Sources include differential downhole fractionation (LIEF), `matrix effects' and ablation volume differences, which result in irreproducibility of the same reference material across sessions. Current mitigation methods include correcting for LIEF mathematically, using matrix-matched reference materials, annealing material to reduce or eliminate radiation damage effects and tuning for robust plasma conditions. Reducing the depth and volume of ablation can also mitigate these problems and should contribute to the reduction of the uncertainty ceiling. Reducing analysed volume leads to increased detection efficiency, reduced matrix-effects, eliminates LIEF, obviates ablation rate differences and reduces the likelihood of intercepting complex growth zones with depth, thereby apparently improving material homogeneity. High detection efficiencies (% level) and low sampling volumes (20um box, 1-2um deep) can now be achieved using MC-ICP-MS such that low volume ablations should be considered part of the toolbox of methods targeted at improving the reproducibility of LA-ICP-MS U-Pb geochronology. In combination with other strategies these improvements should be feasible on any ICP platform. However, reducing the volume of analysis reduces detected counts and requires a change of analytical approach in order to mitigate this. Appropriate strategies may include the use of high efficiency cell and torch technologies and the optimisation of acquisition protocols and data handling techniques such as condensing signal peaks, using log ratios and total signal integration. The tools required to break the 2% (2s) uncertainty ceiling in LA-ICP-MS U-Pb geochronology are likely now known but require a coherent strategy and change of approach to combine their implementation and realise

  4. Trace metal contaminants in sediments and soils: comparison between ICP and XRF quantitative determination

    Directory of Open Access Journals (Sweden)

    Congiu A.

    2013-04-01

    Full Text Available A mineralization method HCl-free for heavy metals analysis in sediments and soils by DRC-ICP-MS was developed. The procedure, which uses concentrated nitric, hydrofluoric acid and hydrogen peroxide, was applied for the analysis of arsenic, cadmium, chromium, nickel and vanadium. The same samples were then analyzed, as pressed pellets, by wavelength dispersive X ray fluorescence (WD-XRF using the dedicated PANalytical Pro Trace solution for the determination of trace elements. Comparison of ICP and XRF data showed good agreement for the elements under investigation, unless for chromium in soils, which recovery was not complete.

  5. {sup 99}Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, L.A.

    1998-05-01

    A means of analyzing {sup 99}Tc in urine by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Historically, {sup 99}Tc analysis was based on the radiometric detection of the 293 keV E{sub Max} beta decay product by liquid scintillation or gas flow proportional counting. In a urine matrix, the analysis of{sup 99}Tc is plagued with many difficulties using conventional radiometric methods. Difficulties originate during chemical separation due to the volatile nature of Tc{sub 2}O{sub 7} or during radiation detection due to color or chemical quenching. A separation scheme for {sup 99}Tc detection by ICP-MS is given and is proven to be a sensitive and robust analytical alternative. A comparison of methods using radiometric and mass quantitation of {sup 99}Tc has been conducted in water, artificial urine, and real urine matrices at activity levels between 700 and 2,200 dpm/L. Liquid scintillation results based on an external standard quench correction and a quench curve correction method are compared to results obtained by ICP-MS. Each method produced accurate results, however the precision of the ICP-MS results is superior to that of liquid scintillation results. Limits of detection (LOD) for ICP-MS and liquid scintillation detection are 14.67 and 203.4 dpm/L, respectively, in a real urine matrix. In order to determine the basis for the increased precision of the ICP-MS results, the detection sensitivity for each method is derived and measured. The detection sensitivity for the {sup 99}Tc isotope by ICP-MS is 2.175 x 10{sup {minus}7} {+-} 8.990 x 10{sup {minus}9} and by liquid scintillation is 7.434 x 10{sup {minus}14} {+-} 7.461 x 10{sup {minus}15}. A difference by seven orders of magnitude between the two detection systems allows ICP-MS samples to be analyzed for a period of 15 s compared to 3,600 s by liquid scintillation counting with a lower LOD.

  6. Determination of iron in highly-saline matrices by FIA-ICP-MS

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    Analysis of iron by inductively-coupled-plasma mass-spectrometry (ICP-MS) may be significantly improved by applying a protocol of flow-injection analysis. The iron species of the sample was preconcentrated by an ammonia buffer at pH = 9.2 on a filterless nylon-knotted reactor, and the adsorbed...... species were subsequently eluted by hydrochloric acid and analysed by ICP-MS. During the FIA step of preconcentration, a high degree of salinity did not influence the adsorption mechanism of iron, which may be related to formation of iron-hydroxide complexes at the sites of amide moieties of the nylon...

  7. Analysis of I-Br-Cl in single fluid inclusions by LA-ICP-MS

    Science.gov (United States)

    Giehl, C.; Fusswinkel, T.; Beermann, O.; Garbe-Schönberg, D.; Scholten, L.; Wagner, T.

    2017-12-01

    Halogens are excellent tracers of hydrothermal fluid sources and in-situ LA-ICP-MS analysis of Cl and Br in single fluid inclusions has provided fundamentally new insight into hydrothermal fluid flow and ore formation. There is mounting evidence that enrichment and depletion of Br relative to Cl may be caused by a number of processes beyond seawater evaporation and halite dissolution which cannot be discriminated on the basis of Br/Cl ratios alone. Expanding the analytical capabilities of fluid inclusion LA-ICP-MS analysis to include iodine would allow to discern between selective and coupled enrichment processes of Cl, Br and I, even in geologically complex samples that are inaccessible to bulk extraction techniques. We present iodine concentration data determined by LA-ICP-MS analysis of synthetic fluid inclusions, using the Sca17 scapolite reference material for external standardization (Seo et al., 2011). Iodine concentrations in Sca17 were determined using the Durango apatite standard. Four starting solutions containing I (0.3, 1.5, 27, 78 µg/g), Br (941, 1403, 2868, 4275 µg/g), Na (30.7, 94.7 mg/g), and Cl (50, 137 mg/g) (analyzed by ICP-OES and ICP-MS at CAU Kiel) were prepared by dissolving reagent grade chemical powders in ultra-pure water. Spherical inclusions (up to 40 µm) were synthesized from the starting solutions in pre-cracked, HF-treated synthetic quartz crystals which were placed in gold capsules and equilibrated at 600°C, 100/200 MPa in cold seal pressure vessels. Fluid inclusion LA-ICP-MS analysis (University of Helsinki) yielded average I concentrations in excellent agreement with the starting solutions (27.3 µg/g ± 14 %RSD for the 27 µg/g solution and 77.6 µg/g ± 8.3 %RSD for the 78 µg/g solution). Average Br and I concentrations deviate less than 10 % from solution concentration values. For the low I concentration solutions, the synthetic inclusions were too small to detect I. Thus, given suitable standard materials and sufficient

  8. Characterization of nuclear materials by laser ablation ICP(SF)MS for nuclear forensic purposes

    International Nuclear Information System (INIS)

    Stefanka, Z.; Katona, R.; Varga, Z.

    2009-01-01

    Full text: The task of the categorization and characterization of nuclear materials of unknown origin has been delegated to the Institute of Isotopes of the Hungarian Academy of Sciences in 1996 by a governmental decree. Since the investigated materials are forensic evidences special attention was paid for minimizing the required sample amount. Therefore LA-ICP(SF)MS has been developed and also applied for the determination of isotopic composition, production date and the concentration of trace impurities. The LA-ICP(SF)MS methods were validated by inter-laboratory comparisons and were applied for analysis of uranium oxide pellets seized in Hungary. (author)

  9. Control Multivariable por Desacoplo

    Directory of Open Access Journals (Sweden)

    Fernando Morilla

    2013-01-01

    Full Text Available Resumen: La interacción entre variables es una característica inherente de los procesos multivariables, que dificulta su operación y el diseño de sus sistemas de control. Bajo el paradigma de Control por desacoplo se agrupan un conjunto de metodologías, que tradicionalmente han estado orientadas a eliminar o reducir la interacción, y que recientemente algunos investigadores han reorientado con objetivos de solucionar un problema tan complejo como es el control multivariable. Parte del material descrito en este artículo es bien conocido en el campo del control de procesos, pero la mayor parte de él son resultados de varios años de investigación de los autores en los que han primado la generalización del problema, la búsqueda de soluciones de fácil implementación y la combinación de bloques elementales de control PID. Esta conjunción de intereses provoca que no siempre se pueda conseguir un desacoplo perfecto, pero que sí se pueda conseguir una considerable reducción de la interacción en el nivel básico de la pirámide de control, en beneficio de otros sistemas de control que ocupan niveles jerárquicos superiores. El artículo resume todos los aspectos básicos del Control por desacoplo y su aplicación a dos procesos representativos: una planta experimental de cuatro tanques acoplados y un modelo 4×4 de un sistema experimental de calefacción, ventilación y aire acondicionado. Abstract: The interaction between variables is inherent in multivariable processes and this fact may complicate their operation and control system design. Under the paradigm of decoupling control, several methodologies that traditionally have been addressed to cancel or reduce the interactions are gathered. Recently, this approach has been reoriented by several researchers with the aim to solve such a complex problem as the multivariable control. Parts of the material in this work are well known in the process control field; however, most of them are

  10. Analytical data and sample locality map for aqua-regia leachates of stream sediments analyzed by ICP, and emission spectrographic and ICP results for many NURE stream sediments from the Killik River Quadrangle, Alaska

    International Nuclear Information System (INIS)

    Motooka, J.M.; Adrian, B.M.; Church, S.E.; McDougal, C.M.; Fife, J.B.

    1989-01-01

    A U.S. Geological Survey report is presented giving analytical data and sample locality map for aqua-regia leachates of stream sediments analyzed by ICP, and emission spectrographic and ICP results for many NURE stream sediments from the Killik River Quadrangle, Alaska

  11. Analysis of the characteristics of AE wave using boring core of sedimentary soft rock and study on the field measurement of AE for the evaluation of EDZ (Joint research)

    International Nuclear Information System (INIS)

    Aoki, Kenji; Mito, Yoshitada; Minami, Masayuki; Matsui, Hiroya; Niunoya, Sumio

    2007-09-01

    To understand the size and state of EDZ accurately is one of the key issues in the technological development for geological disposal of High-Level Radioactive Waste. As one of these evaluation technologies, AE which is measured directly and evaluates EDZ is paid to attention inside and outside the country, and the utility is reported for the crystalline rock. However, there are few cases to apply AE in sedimentary soft rocks to EDZ evaluation because of the difficulty to measure a few AE waves with small energy. In this study, the authors made a series of laboratory tests including tri-axial test using the stiff and servo-controlled testing machine in order to clarify the possibility to measure AE waves in Neogene siliceous rocks in Horonobe, Hokkaido, Japan (2005). The authors conducted the high stiffness tri-axial compression tests with AE measurements. And, the authors extracted an effective AE parameter to the evaluation of EDZ in the neogene (2005). The authors evaluated the mechanism of EDZ, which assumed from the result in occurrence of crack in the rock by measurement system and DEM analysis, by using the effective parameter (2006). In the EDZ examination which is planned since the second stage, the authors constructed a concept of the necessary measurement and evaluation system (2007). (author)

  12. Application of AE technique for on-line monitoring of quenching in racetrack superconducting coil at cryogenic environment

    International Nuclear Information System (INIS)

    Lee, Jun Hyun; Lee, Min Rae; Shon, Myung Hwan; Kwon, Young Kil

    1998-01-01

    An acoustic emission(AE) technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2 K. The ultimate goal is to ensure the safety and reliability of large superconducting magnet systems by being able to identity and locate the sources of quench in superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current. It was found in this study that there was good correlation between quench current and AE parameters. The source location of quenching in superconducting magnet was also discussed on the hashing of correlation between magnet voltage and AE energy.

  13. Fatigue Crack Growth Behavior of and Recognition of AE Signals from Composite Patch-Repaired Aluminum Panel

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Kwon, Oh Yang; Jang, Yong Joon

    2007-01-01

    The fatigue crack growth behavior of a cracked and patch-repaired Ah2024-T3 panel has been monitored by acoustic emission(AE). The overall crack growth rate was reduced The crack propagation into the adjacent hole was also retarded by introducing the patch repair. AE signals due to crack growth after the patch repair and those due to debonding of the plate-patch interface were discriminated by using the principal component analysis. The former showed high center frequency and low amplitude, whereas the latter showed long rise tine, low frequency and high amplitude. This type of AE signal recognition method could be effective for the prediction of fatigue crack growth behavior in the patch-repaired structures with the aid of AE source location

  14. Age dynamics of zinc and iron contents in human hair determined by INAA and ICP-ES

    International Nuclear Information System (INIS)

    Zaichick, V.

    2005-01-01

    Full text: In last decades, the determination of chemical element levels in human hair has been a subject of continual interest in the forensic, clinical, occupational and environmental medicine. Hair has been increasingly used as a monitor for many elements and has been proposed for assessing environmental exposure, nutritional status, and for diagnosis of disease. It has many advantages for assessment over the more traditional kinds of medical objects such as blood and urine because of ease of collection, transport and storage. Also, trace element concentrations in hair samples represent an integrated response over time compared with blood and urine levels, which can rapidly fluctuate in response to variations of nutritional and environmental conditions. The fact that contents of many chemical elements in hair are relatively high also facilitates the analysis. It is known that the result of the hair analysis may not directly relate to the intake amount, nor does it always reflect the amount actually absorbed. Despite these limitations, the analysis of human hair can still provide a basis for estimating ambient exposure to certain elements. The first step in construction of such basis is investigations the national population normal levels of chemical element contents in hair related to sex, age and some other factors under quality control of results. The objectives of this analytical work were to evaluate the reference range of Zn and Fe in adult scalp hair and to evaluate the effect of age and sex on elemental contents. In this study, head hair samples from adult health persons living in or near Obninsk (the small city in rural region 105 km south-west Moscow), were analysed by two methods in three analytical laboratories: instrumental neutron activation analysis (INAA - one laboratory) and atomic emission spectrometry with inductively coupled plasma (ISP-AES - two laboratories). Scalp hair samples were obtained at necropsy from eighty-three cadavers (38 women

  15. On the application of ICP-MS techniques for measuring uranium and plutonium: a Nordic inter-laboratory comparison exercise

    DEFF Research Database (Denmark)

    Qiao, Jixin; Lagerkvist, Petra; Rodushkin, Ilia

    2018-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) techniques are widely used for determination of long-lived radionuclides and their isotopic ratios in the nuclear fields. Uranium (U) and Pu (Pu) isotopes have been determined by many researchers with ICP-MS due to its relatively high sensitiv...

  16. ICP-MS determination of rare earth elements, yttrium, uranium and thorium in niobium-tantalum rich samples

    International Nuclear Information System (INIS)

    Sunilkumar, Beena; Padmasubashini, V.

    2013-01-01

    ICP-MS is a powerful and extremely sensitive technique which has been applied successfully for the determination of REEs in diverse geological samples. In the present work, ICP-MS has been applied for the rapid determination of REEs, yttrium as well as uranium and thorium in niobium and tantalum rich samples, using a fluoride fusion method for sample dissolution

  17. 77 FR 76109 - IAS Energy, Inc., IB3 Networks, Inc., IBroadband, Inc., ICP Solar Technologies, Inc., IdentiPHI...

    Science.gov (United States)

    2012-12-26

    ...., IBroadband, Inc., ICP Solar Technologies, Inc., IdentiPHI, Inc., iDNA, Inc., Immune Network Ltd., Inca Designs, Inc., Indico Technologies, Inc. (n/k/a Indico Resources Ltd.), Infopage, Inc. (a/k/a Tamija Gold... securities of ICP Solar Technologies, Inc. because it has not filed any periodic reports since the period...

  18. Drug-resistant molecular mechanism of CRF01_AE HIV-1 protease due to V82F mutation

    Science.gov (United States)

    Liu, Xiaoqing; Xiu, Zhilong; Hao, Ce

    2009-05-01

    Human immunodeficiency virus type 1 protease (HIV-1 PR) is one of the major targets of anti-AIDS drug discovery. The circulating recombinant form 01 A/E (CRF01_AE, abbreviated AE) subtype is one of the most common HIV-1 subtypes, which is infecting more humans and is expanding rapidly throughout the world. It is, therefore, necessary to develop inhibitors against subtype AE HIV-1 PR. In this work, we have performed computer simulation of subtype AE HIV-1 PR with the drugs lopinavir (LPV) and nelfinavir (NFV), and examined the mechanism of resistance of the V82F mutation of this protease against LPV both structurally and energetically. The V82F mutation at the active site results in a conformational change of 79's loop region and displacement of LPV from its proper binding site, and these changes lead to rotation of the side-chains of residues D25 and I50'. Consequently, the conformation of the binding cavity is deformed asymmetrically and some interactions between PR and LPV are destroyed. Additionally, by comparing the interactive mechanisms of LPV and NFV with HIV-1 PR we discovered that the presence of a dodecahydroisoquinoline ring at the P1' subsite, a [2-(2,6-dimethylphenoxy)acetyl]amino group at the P2' subsite, and an N2 atom at the P2 subsite could improve the binding affinity of the drug with AE HIV-1 PR. These findings are helpful for promising drug design.

  19. Identification of an ICP27-responsive element in the coding region of a herpes simplex virus type 1 late gene.

    Science.gov (United States)

    Sedlackova, Lenka; Perkins, Keith D; Meyer, Julia; Strain, Anna K; Goldman, Oksana; Rice, Stephen A

    2010-03-01

    During productive herpes simplex virus type 1 (HSV-1) infection, a subset of viral delayed-early (DE) and late (L) genes require the immediate-early (IE) protein ICP27 for their expression. However, the cis-acting regulatory sequences in DE and L genes that mediate their specific induction by ICP27 are unknown. One viral L gene that is highly dependent on ICP27 is that encoding glycoprotein C (gC). We previously demonstrated that this gene is posttranscriptionally transactivated by ICP27 in a plasmid cotransfection assay. Based on our past results, we hypothesized that the gC gene possesses a cis-acting inhibitory sequence and that ICP27 overcomes the effects of this sequence to enable efficient gC expression. To test this model, we systematically deleted sequences from the body of the gC gene and tested the resulting constructs for expression. In so doing, we identified a 258-bp "silencing element" (SE) in the 5' portion of the gC coding region. When present, the SE inhibits gC mRNA accumulation from a transiently transfected gC gene, unless ICP27 is present. Moreover, the SE can be transferred to another HSV-1 gene, where it inhibits mRNA accumulation in the absence of ICP27 and confers high-level expression in the presence of ICP27. Thus, for the first time, an ICP27-responsive sequence has been identified in a physiologically relevant ICP27 target gene. To see if the SE functions during viral infection, we engineered HSV-1 recombinants that lack the SE, either in a wild-type (WT) or ICP27-null genetic background. In an ICP27-null background, deletion of the SE led to ICP27-independent expression of the gC gene, demonstrating that the SE functions during viral infection. Surprisingly, the ICP27-independent gC expression seen with the mutant occurred even in the absence of viral DNA synthesis, indicating that the SE helps to regulate the tight DNA replication-dependent expression of gC.

  20. IMPLEMENTACIÓN EN HARDWARE DEL ESTÁNDAR DE ENCRIPTACIÓN AVANZADO (AES, EN UNA PLATAFORMA FPGA, EMPLEANDO EL MICROCONTROLADOR PICOBLAZETM

    Directory of Open Access Journals (Sweden)

    J. Fernando Piñal M.

    2009-01-01

    Full Text Available En este trabajo analizamos las características del estándar de encriptación avanzado AES y suimplementación en una tarjeta de desarrollo FPGA Spartan-3E , utilizando una de las herramientas de procesamiento embebido del fabricante Xilinx®, el microcontrolador PicoBlaze¿. Además se diseñó un bloque en VHDL, el cual es el encargado de realizar la interfaz entre el microcontrolador y los periféricos de entrada- salida de la tarjeta. El ingreso de los datos a cifrar puede realizarse de dos maneras: mediante un teclado conectado al puerto PS/2 de la tarjeta o transmitiéndolos por el puerto serie de una computadora personal; para esto se diseñó una interfaz programada en Matlab¿. Los datos cifrados pueden observarse en el exhibidor LCD de la tarjeta de desarrollo, o bien se pueden transmitir en modo serial hacia una computadora personal. Estas opciones de funcionamiento del sistema se seleccionan mediante los interruptores deslizables de la tarjeta de desarrollo. La verificación del funcionamiento del sistema se realiza haciendo uso del documento oficial que describe a AES: FIPS-PUB 197. Aun cuando se implementó el algoritmo en un sistema basado en un procesador, se obtuvo un buen rendimiento. Se incluye la comparación del desempeño de nuestro diseño con otras arquitecturas que implementan también el mismo algoritmo.

  1. A Novel Detection Platform for Shrimp White Spot Syndrome Virus Using an ICP11-Dependent Immunomagnetic Reduction (IMR) Assay.

    Science.gov (United States)

    Liu, Bing-Hsien; Lin, Yu-Chen; Ho, Chia-Shin; Yang, Che-Chuan; Chang, Yun-Tsui; Chang, Jui-Feng; Li, Chun-Yuan; Cheng, Cheng-Shun; Huang, Jiun-Yan; Lee, Yen-Fu; Hsu, Ming-Hung; Lin, Feng-Chun; Wang, Hao-Ching; Lo, Chu-Fang; Yang, Shieh-Yueh; Wang, Han-Ching

    2015-01-01

    Shrimp white spot disease (WSD), which is caused by white spot syndrome virus (WSSV), is one of the world's most serious shrimp diseases. Our objective in this study was to use an immunomagnetic reduction (IMR) assay to develop a highly sensitive, automatic WSSV detection platform targeted against ICP11 (the most highly expressed WSSV protein). After characterizing the magnetic reagents (Fe3O4 magnetic nanoparticles coated with anti ICP11), the detection limit for ICP11 protein using IMR was approximately 2 x 10(-3) ng/ml, and the linear dynamic range of the assay was 0.1~1 x 10(6) ng/ml. In assays of ICP11 protein in pleopod protein lysates from healthy and WSSV-infected shrimp, IMR signals were successfully detected from shrimp with low WSSV genome copy numbers. We concluded that this IMR assay targeting ICP11 has potential for detecting the WSSV.

  2. Development of analytical procedures for determination of total chromium by quadrupole ICP-MS and high-resolution ICP-MS, and hexavalent chromium by HPLC-ICP-MS, in different materials used in the automotive industry.

    Science.gov (United States)

    Séby, F; Gagean, M; Garraud, H; Castetbon, A; Donard, O F X

    2003-10-01

    A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP-MS). High resolution (HR) ICP-MS was used to examine the influence of polyatomic interferences on the detection of the (52)Cr(+) and (53)Cr(+) isotopes. If there was strong interference with m/ z 52 for plastic materials, it was possible to use quadrupole ICP-MS for m/ z 53 if digestions were performed with HNO(3)+H(2)O(2). This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH(4)(+)/NH(3) buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC-ICP-MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc-nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient

  3. Multielemental speciation analysis by advanced hyphenated technique - HPLC/ICP-MS: A review.

    Science.gov (United States)

    Marcinkowska, Monika; Barałkiewicz, Danuta

    2016-12-01

    Speciation analysis has become an invaluable tool in human health risk assessment, environmental monitoring or food quality control. Another step is to develop reliable multielemental speciation methodologies, to reduce costs, waste and time needed for the analysis. Separation and detection of species of several elements in a single analytical run can be accomplished by high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC/ICP-MS). Our review assembles articles concerning multielemental speciation determination of: As, Se, Cr, Sb, I, Br, Pb, Hg, V, Mo, Te, Tl, Cd and W in environmental, biological, food and clinical samples analyzed with HPLC/ICP-MS. It addresses the procedures in terms of following issues: sample collection and pretreatment, selection of optimal conditions for elements species separation by HPLC and determination using ICP-MS as well as metrological approach. The presented work is the first review article concerning multielemental speciation analysis by advanced hyphenated technique HPLC/ICP-MS. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Determination of heavy metals in groundwater samples - ICP-MS analysis and evaluation

    International Nuclear Information System (INIS)

    Leiterer, M.; Muench, U.

    1994-01-01

    An analytical programme which permits the direct, simultaneous determination of Al, As, Cd, Cr, Cu, Mn, Ni, Pb and Zn in groundwater samples was developed for ICP-MS. Spectral mass interferences, attributable to great differences in groundwater matrices, precision and accuracy have been discussed. The evaluation of analytical results was demonstrated for selected sampling points of the groundwater observation network of Thuringia. (orig.)

  5. Laser solid sampling for a solid-state-detector ICP emission spectrometer

    International Nuclear Information System (INIS)

    Noelte, J.; Moenke-Blankenburg, L.; Schumann, T.

    1994-01-01

    Solid sampling with laser vaporization has been coupled to an ICP emission spectrometer with an Echelle optical system and a solid-state-detector for the analysis of steel and soil samples. Pulsation of the vaporized material flow was compensated by real-time background correction and internal standardization, resulting in good accuracy and precision. (orig.)

  6. Ir and Rare Earth's Elements determination by Neutron Activation Analysis and ICP - MS in soil samples

    Science.gov (United States)

    Salvini, A.; Cattadori, C.; Broggini, C.; Cagnazzo, M.; Ori, Gian Gabriele; Nisi, S.; Borio, A.; Manera, S.

    2006-05-01

    The platinum metals depleted in the earth's crust are relative to their cosmic abundance; concentration of these elements in sediments may thus indicate influxes of extraterrestrial material. Analysis of these parameters are done easily by Neutron Activation Analysis (NAA) and comparative results with ICP-MS technique show a good match. Results, adjust parameters and limits of this method will be displayed in tables.

  7. Determination of 210Pb at ultra-trace levels in water by ICP-MS

    International Nuclear Information System (INIS)

    Lariviere, D.; Reiber, K.M.; Evans, R.D.; Cornett, R.J.

    2005-01-01

    210 Pb (t 1/2 = 22.26 years) is one of the most difficult naturally occurring radionuclides to analyze directly via radiometric measurement due to its low-energy radioactive decay. In this work, inductively coupled plasma mass spectrometry (ICP-MS) was investigated as a possible alternative to radiometric counting for the determination of 210 Pb. The formation of isobaric and polyatomic (molecular) interferences was studied and various strategies (i.e. co-precipitation, extraction chromatography, and derivatization) were tested to assess their usefulness in reducing these interferences. In addition, the potential of these strategies as pre-concentration methods was demonstrated. A 210 Pb pre-concentration of >300-fold and recoveries of 63-73% were obtained using a combined co-precipitation and extraction chromatography protocol followed by derivatization using an ethylating reagent. The abundance sensitivity at m/z = 210 in the presence of stable Pb was also investigated for three types of mass spectrometers (sector-field (ICP-SFMS), quadrupole-based (ICP-QMS), and quadrupole-based with a dynamic reaction cell (ICP-QMS (DRC))). Finally, the method was applied to determine 210 Pb in water samples and a detection limit of 90 mBq L -1 (10 pg L -1 ) was obtained

  8. Analysis of trace uranium and plutonium in environmental water sample by ICP-MS

    International Nuclear Information System (INIS)

    Liu Xuemei

    2004-12-01

    The analysis of trace Uranium and Plutonium in environmental water is very important in the environment inspect. The preparation method of water samples are introduced and several common used method are compared. The analysis process and the calibration method with ICP-MS are discussed in detail considering present conditions. (author)

  9. Uncertainties combined in algae and water in chemical analysis in determinations with ICP-OES

    International Nuclear Information System (INIS)

    Souza, Poliana Santos de

    2014-01-01

    One way to determine if some trace elements in algae and water is through uncertainty calculations. Spectrometry and inductively coupled plasma optical emission (ICP-OES) is widely used in this procedure, because it allows the analysis in waters and areas of solid samples. Thus, some elements (Fe, Ca and Mg) were used to calculate the uncertainty. (author)

  10. Surfactant assisted chemical vapour generation of silver for AAS and ICP-OES: a mechanistic study

    Czech Academy of Sciences Publication Activity Database

    Matoušek, Tomáš; Sturgeon, R. E.

    2003-01-01

    Roč. 18, č. 5 (2003), s. 487-494 ISSN 0267-9477 Institutional research plan: CEZ:AV0Z4031919 Keywords : vapour generation * ICP-OES * silver Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.200, year: 2003

  11. Application of ICP-MS to a trace elements mass balance study in a power plant

    NARCIS (Netherlands)

    Bettinelli, M.; Spezia, S.; Fiore, A.; Pastorelli, N.; Terni, C.; Holland, G.; Tanner, S.D.

    2001-01-01

    The distributions of seven trace elements in a power plant are detd. in 3 fuels (Orimulsion, coal, and fuel oil) and output flows, i.e., ash, wastewater, gypsum, and emulsions by using ICP-MS. The power plant is equipped with sulfur oxide and nitrogen oxide removal facilities. [on SciFinder (R)

  12. Programs in Fortran language for reporting the results of the analyses by ICP emission spectroscopy

    International Nuclear Information System (INIS)

    Roca, M.

    1985-01-01

    Three programs, written in FORTRAN IV language, for reporting the results of the analyses by ICP emission spectroscopy from data stored in files on floppy disks have been developed. They are intended, respectively, for the analyses of: 1) waters, 2) granites and slates, and 3) different kinds of geological materials. (Author) 8 refs

  13. Determination of Trace Elements in Uranium by HPLC-ID-ICP-MS: NTNFC Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Manard, Benjamin Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wylie, Ernest Miller II [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Xu, Ning [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tandon, Lav [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-19

    This report covers the FY 16 effort for the HPLC-ID-ICP-MS methodology 1) sub-method validation for the group I&II elements, 2) sub-method stood-up and validation for REE, 3) sub-method development for the transition element, and 4) completion of a comprehensive SOP for three families of elements.

  14. Operationalisering van de flow-injectietechniek in combinatie met ICP-MS

    NARCIS (Netherlands)

    Velde-Koerts T van der; Boer JLM de; LAC

    1994-01-01

    In dit onderzoek werd de flow-injectietechniek gecombineerd met ICP-MS. Hoewel de onderste analysegrenzen iets hoger waren dan bij continue verstuiving, heeft de flow-injectietechniek een aantal belangrijke voordelen: ten eerste het kleine monstervolume dat nodig is voor de analyse (0,7 ml,

  15. Sulfur-induced offsets in MC-ICP-MS silicon-isotope measurements

    NARCIS (Netherlands)

    van den Boorn, S.; Vroon, P.Z.; van Bergen, M.J.

    2009-01-01

    Sample preparation methods for MC-ICP-MS silicon-isotope measurements often involve a cation-exchange purification step. A previous study has argued that this would suffice for geological materials, as the occasional enrichment of anionic species would not compromise silicon-isotope analysis. Here

  16. Application of ICP-MS in Environmental Sampling Analysis for Safeguards

    International Nuclear Information System (INIS)

    Eko Pudjadi; Petrus Zacharias; Budi Prayitno

    2004-01-01

    Environmental samples measured by ICP-MS were analyzed for safeguards. There are two isotopes in environmental sampling that is used to find out the origin of nuclear materials and verify undeclared nuclear activities. Uranium isotopes are 234 U, 235 U, 236 U and 238 U and Plutonium isotopes are 239 Pu, 240 Pu, 241 Pu and 242 Pu. Uranium isotopes are used to verify an existing of nuclear power plants, enrichment plants or reprocessing plants. Plutonium isotopes are used to clarify global fallout from nuclear weapon testing and accident of nuclear facility or military purposes. The high sensitivity of ICP-MS can detect the isotopic fingerprint and trace elements in ppb concentration; ICP-MS has been applied to measure 235 U isotopic ratio and 240 Pu/ 239 Pu isotopic ratios. The sensitivity of ICP-MS is high precision and low operational cost in environmental sampling and can be considered in nuclear power design based on safeguards for development countries. (author)

  17. Sulphur-induced offsets in MC-ICP-MS silicon-isotope measurements

    NARCIS (Netherlands)

    van den Boorn, S.; Vroon, P.Z.; van Bergen, M.J.

    2010-01-01

    Sample preparation methods for MC-ICP-MS silicon-isotope measurements often involve a cation-exchange purification step. A previous study has argued that this would suffice for geological materials, as the occasional enrichment of anionic species would not compromise silicon-isotope analysis. Here

  18. Online immunocapture ICP-MS for the determination of the metalloprotein ceruloplasmin in human serum.

    Science.gov (United States)

    Bernevic, Bogdan; El-Khatib, Ahmed H; Jakubowski, Norbert; Weller, Michael G

    2018-04-02

    The human copper-protein ceruloplasmin (Cp) is the major copper-containing protein in the human body. The accurate determination of Cp is mandatory for the reliable diagnosis of several diseases. However, the analysis of Cp has proven to be difficult. The aim of our work was a proof of concept for the determination of a metalloprotein-based on online immunocapture ICP-MS. The immuno-affinity step is responsible for the enrichment and isolation of the analyte from serum, whereas the compound-independent quantitation with ICP-MS delivers the sensitivity, precision, and large dynamic range. Off-line ELISA (enzyme-linked immunosorbent assay) was used in parallel to confirm the elution profile of the analyte with a structure-selective method. The total protein elution was observed with the 32 S mass trace. The ICP-MS signals were normalized on a 59 Co signal. The human copper-protein Cp could be selectively determined. This was shown with pure Cp and with a sample of human serum. The good correlation with off-line ELISA shows that Cp could be captured and eluted selectively from the anti-Cp affinity column and subsequently determined by the copper signal of ICP-MS.

  19. Prestatiekenmerken van een TotalQuant-elementanalyse met ICP-MS

    NARCIS (Netherlands)

    Velde-Koerts T van der; LAC

    1998-01-01

    TotalQuant-analyse met ICP-MS is een geschikte methode om snel oplossingen van diverse materialen te scannen op alle elementen van het periodieke systeem, behalve H, N, O, F, edelgassen en kortlevende (radio-actieve) elementen. Bij een TotalQuant-analyse wordt gebruik gemaakt van een standaard

  20. Aerosol absorption coefficient and Equivalent Black Carbon by parallel operation of AE31 and AE33 aethalometers at the Zeppelin station, Ny Ålesund, Svalbard

    Science.gov (United States)

    Eleftheriadis, Konstantinos; Kalogridis, Athina-Cerise; Vratolis, Sterios; Fiebig, Markus

    2016-04-01

    Light absorbing carbon in atmospheric aerosol plays a critical role in radiative forcing and climate change. Despite the long term measurements across the Arctic, comparing data obtained by a variety of methods across stations requires caution. A method for extracting the aerosol absorption coefficient from data obtained over the decades by filter based instrument is still under development. An IASOA Aerosol working group has been initiated to address this and other cross-site aerosol comparison opportunities. Continuous ambient measurements of EBC/light attenuation by means of a Magee Sci. AE-31 aethalometer operating at the Zeppelinfjellet station (474 m asl; 78°54'N, 11°53'E), Ny Ålesund, Svalbard, have been available since 2001 (Eleftheriadis et al, 2009), while a new aethalometer model (AE33, Drinovec et al, 2014) has been installed to operate in parallel from the same inlet since June 2015. Measurements are recorded by a Labview routine collecting all available parameters reported by the two instrument via RS232 protocol. Data are reported at 1 and 10 minute intervals as averages for EBC (μg m-3) and aerosol absorption coefficients (Mm-1) by means of routine designed to report Near Real Time NRT data at the EBAS WDCA database (ebas.nilu.no) Results for the first 6 month period are reported here in an attempt to evaluate comparative performance of the two instruments in terms of their response with respect to the variable aerosol load of light absorbing carbon during the warm and cold seasons found in the high arctic. The application of available conversion schemes for obtaining the absorption coefficient by the two instruments is found to demonstrate a marked difference in their output. During clean periods of low aerosol load (EBC origin was also conducted. Drinovec, L., Močnik, G., Zotter, P., Prévôt, A. S. H., Ruckstuhl, C., Coz, E., Rupakheti, M., Sciare, J., Müller, T., Wiedensohler, A., and Hansen, A. D. A. The "dual-spot" Aethalometer: an