WorldWideScience

Sample records for polyvinyl chloride conduit

  1. Polyvinyl chloride resin

    International Nuclear Information System (INIS)

    Kim, Hong Jae

    1976-06-01

    This book contains polyvinyl chloride resin industry with present condition such as plastic industry and polyvinyl chloride in the world and Japan, manufacture of polyvinyl chloride resin ; suspension polymerization and solution polymerization, extruding, injection process, hollow molding vinyl record, vacuum forming, polymer powders process, vinyl chloride varnish, vinyl chloride latex, safety and construction on vinyl chloride. Each chapter has descriptions on of process and kinds of polyvinyl chloride resin.

  2. 40 CFR 61.65 - Emission standard for ethylene dichloride, vinyl chloride and polyvinyl chloride plants.

    Science.gov (United States)

    2010-07-01

    ... dichloride, vinyl chloride and polyvinyl chloride plants. 61.65 Section 61.65 Protection of Environment... AIR POLLUTANTS National Emission Standard for Vinyl Chloride § 61.65 Emission standard for ethylene dichloride, vinyl chloride and polyvinyl chloride plants. An owner or operator of an ethylene dichloride...

  3. [Survey of plasticizers in polyvinyl chloride toys].

    Science.gov (United States)

    Abe, Yutaka; Yamaguchi, Miku; Mutsuga, Motoh; Hirahara, Yoshichika; Kawamura, Yoko

    2012-01-01

    Plasticizers in 101 samples of polyvinyl chloride (PVC) toys on the Japanese market were surveyed. No phthalates were detected in designated toys, though bis(2-ethylhexyl)phthalate, diisononyl phthalate, diisobutyl phthalate, dibutyl phthalate, diisodecyl phthalate and benzyl butyl phthalate were detected in more than half of other toys. 2,2,4-Tributyl-1,3-pentanediol diisobutylate, o-acetyl tributyl citrate, adipates and diacetyl lauroyl glycerol, which are alternative plasticizers to phthalates, were detected. The results of structural analysis confirmed the presence of di(2-ethylhexyl)terephthalate, tributyl citrate, diisononyl 1,2-cyclohexanedicarboxylate and neopentyl glycol esters; these have not previonsly been reported in Japan. There appears to be a shift in plasticizers used for designated toys from phthalates to new plasticizers, and the number of different plasticizers is increasing.

  4. Process for the graft polymerization of polyvinyl chloride. [electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kageyama, E; Kusama, Y; Udagawa, A; Hashimoto, S

    1970-08-14

    The graft polymerization of acrylonitrile on polyvinyl chloride is effected by simultaneous irradiation with ionizing radiations in a reaction bath consisting of 30% acrylonitrile and 70% n-hexane. The acrylonitrile-hydrocarbon reaction bath increases the graft efficiency markedly when the content of acrylonitrile is 30%. In this case, the formation rate of acrylonitrile homopolymer decreases with a decrease in the content of acrylonitrile. The immersion time may be from a few minutes to a few hours, depending on the type, property and desired graft efficiency of the polyvinyl chloride resin. The polyvinyl chloride may be any available on the market. The acrylonitrile may contain a small quantity of copolymerizable monomer if it does not influence the thermal property of the polyvinyl chloride graft polymer. The ionizing radiations must have enough energy to form an ion pair by removing one electron from one atom of a gas. In examples, 10 g of polyvinyl chloride in powder form were immersed in 100 cc of a mixed solution consisting of 70% to 90% of n-hexane and 10% to 30% of acrylonitrile. The polyvinyl chloride in the solution was exposed to electron beams of 2 Mrad at a dose rate of 7.2 x 10/sup 7/ rad/hr. under a reduced pressure. The graft efficiency was 50% to 80% and the yield of acrylonitrile homopolymer was 0.42 g to 1.26 g.

  5. New crosslinked polyvinyl chloride insulated wire by electron beam irradiation

    International Nuclear Information System (INIS)

    Takahata, Norio; Shingyouchi, Kazuo; Sato, Masakatsu; Sasaki, Hidemi; Terunuma, Haruji

    1978-01-01

    The polyvinyl chloride-coated wires crosslinked by electron beam irradiation have made rapid progress as electric and electronic wiring material and grown to hold a firm position in this field. In response to the requirements for wires with the advance of electronic equipments, Hitachi Cable Ltd. developed a peculiar graft polymer consisting of chlorinated polyethylene and polyvinyl chloride. To this polymer, the characteristics of a very wide range from toughness to flexibility can be given, and the crosslinked polyvinyl chloride wires utilizing these characteristics were put in practical use. Many kinds of the wires were developed as follows; 105 deg. C rating crosslinked vinyl-coated wires authorized by UL and CSA standards, crosslinked vinyl-coated wires with excellent flexibility, high strength crosslinked vinyl-coated wires with thin coating and crosslinked vinyl-coated wires for automobiles. They are expected to be developed into other new fields and applications. (Kobatake, H.)

  6. 40 CFR 61.64 - Emission standard for polyvinyl chloride plants.

    Science.gov (United States)

    2010-07-01

    ... chloride plants. 61.64 Section 61.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Standard for Vinyl Chloride § 61.64 Emission standard for polyvinyl chloride plants. An owner or operator of a polyvinyl chloride plant shall comply with the requirements of this section and § 61.65. (a...

  7. Modeling polyvinyl chloride Plasma Modification by Neural Networks

    Science.gov (United States)

    Wang, Changquan

    2018-03-01

    Neural networks model were constructed to analyze the connection between dielectric barrier discharge parameters and surface properties of material. The experiment data were generated from polyvinyl chloride plasma modification by using uniform design. Discharge voltage, discharge gas gap and treatment time were as neural network input layer parameters. The measured values of contact angle were as the output layer parameters. A nonlinear mathematical model of the surface modification for polyvinyl chloride was developed based upon the neural networks. The optimum model parameters were obtained by the simulation evaluation and error analysis. The results of the optimal model show that the predicted value is very close to the actual test value. The prediction model obtained here are useful for discharge plasma surface modification analysis.

  8. Ultrastructural immunocytochemistry of particulate fractions using polyvinyl chloride microculture wells.

    Science.gov (United States)

    Wray, B E; Sealock, R

    1984-10-01

    A method is described for immunoelectron microscopy of particulate subcellular fractions using polyvinyl chloride (soft) microculture wells as mechanical supports and reaction vessels. Appropriate quantities of particles are centrifuged onto the well bottoms, fixed and permeabilized if necessary, then labeled by standard procedures, fixed in glutaraldehyde and tannic acid, and prepared for thin section electron microscopy. The centrifugation, the fixations, and the embedment in Epon are discussed in detail.

  9. MECHANICAL PROPERTIES OF BLENDS OF PAMAM DENDRIMERS WITH POLY(VINYL CHLORIDE) AND POLY(VINYL ACETATE)

    Science.gov (United States)

    Hybrid blends of poly(amidoamine) PAMAM dendrimers with two linear high polymers, poly(vinyl chloride), PVC, and poly(vinyl acetate), PVAc, are reported. The interaction between the blend components was studied using dynamic mechanical analysis, xenon nuclear magnetic resonacne ...

  10. Continuous microcellular foaming of polyvinyl chloride and compatibilization of polyvinyl chloride and polylactide composites

    Science.gov (United States)

    Shah, Bhavesh

    This dissertation focuses on overcoming existing limitations of WPCs which prevent them from realizing their full market potential. These limitations include: (i) lack of a continuous extrusion process for microcellular foaming of polyvinyl chloride (PVC) and its composites using supercritical fluids to reduce the high density of the WPCs, (ii) need for an efficient coupling agent for WPCs to overcome the poor compatibility between wood and plastic, and (iii) unproven use of wood as a filler for the biopolymer polylactide (PLA) to make "green" composites. These limitations were addressed through experimentation to develop a continuous extrusion process for microcellular foaming, and through surface modification of wood flour using natural coupling agents. The effects of wood flour, acrylic modifier and plasticizer content on the rheological properties of PVC based WPCs were studied using an extrusion capillary rheometer and a two-level factorial design. Wood flour content and acrylic modifier content were the major factors affecting the die swell ratio. Addition of plasticizer decreased the true viscosity of unfilled and filled PVC, irrespective of the acrylic modifier content. However, the addition of acrylic modifier significantly increased the viscosity of unfilled PVC but decreased the composite viscosity. Results of the rheological study were used to set baseline conditions for the continuous extrusion foaming of PVC WPCs using supercritical CO 2. Effects of material composition and processing conditions on the morphology of foamed samples were investigated. Foamed samples were produced using various material compositions and processing conditions, but steady-state conditions could not be obtained for PVC. Thus the relationships could not be determined. Incompatibility between wood flour and PVC was the focus of another study. The natural polymers chitin and chitosan were used as novel coupling agents to improve interfacial adhesion between the polymer matrix

  11. Fittings of unplasticized polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure - Dimensions of sockets - Metric series

    CERN Document Server

    International Organization for Standardization. Geneva

    1985-01-01

    Fittings of unplasticized polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure - Dimensions of sockets - Metric series

  12. Plastics piping systems for industrial applications – Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) – Specifications for components and the system – Metric series

    CERN Document Server

    Deutsches Institut für Normung. Berlin

    2003-01-01

    Plastics piping systems for industrial applications – Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) – Specifications for components and the system – Metric series

  13. Plastics piping systems for industrial applications : acrylonitrile-butadiene- styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) : specifications for components and the system : metric series

    CERN Document Server

    International Organization for Standardization. Geneva

    2003-01-01

    Plastics piping systems for industrial applications : acrylonitrile-butadiene- styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) : specifications for components and the system : metric series

  14. The influence of polyvinyl chloride (P.V.C.) tubing on the isolated perfused rat heart

    NARCIS (Netherlands)

    Meijler, F.L.; Willebrands, A.F.; Durrer, D.

    1960-01-01

    Some brands of polyvinyl chlorides interfere with cardiac contraction, whereas other brands do not. Chemical investigation showed that the stabilizer is most probably responsibie for the cardiotoxic effect. It is suggested that all types of polyvinyl chloride used for medical and biological

  15. Polyvinyl chloride plastisol breast phantoms for ultrasound imaging.

    Science.gov (United States)

    de Carvalho, Isabela Miller; De Matheo, Lucas Lobianco; Costa Júnior, José Francisco Silva; Borba, Cecília de Melo; von Krüger, Marco Antonio; Infantosi, Antonio Fernando Catelli; Pereira, Wagner Coelho de Albuquerque

    2016-08-01

    Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. A Model Approach for Finding Cleaning Solutions for Plasticized Poly(Vinyl Chloride) Surfaces of Collections Objects

    DEFF Research Database (Denmark)

    Sanz Landaluze, Jon; Egsgaard, Helge; Morales Munoz, Clara

    2014-01-01

    This study focused on developing a surface cleaning treatment for one type of commercially available plasticized poly(vinyl chloride). The effects of cleaning solutions on samples of plasticized poly(vinyl chloride) were examined by several methods. The sample surface, prior to and after artifici...

  17. Terpyridine modified poly(vinyl chloride) : possibilities for supramolecular grafting and crosslinking

    NARCIS (Netherlands)

    Meier, M.A.R.; Schubert, U.S.

    2003-01-01

    Commercially available poly(vinyl chloride) (PVC) was covalently modified with terpyridine supramolecular binding units in a two-step reaction. First, PVC was modified with aromatic thiols to introduce OH functionalities into the polymer backbone, which were subsequently reacted with an

  18. Modeling of the Migration of Glycerol Monoester Plasticizers in Highly Plasticized Poly(vinyl chloride)

    DEFF Research Database (Denmark)

    Lundsgaard, Rasmus; Kontogeorgis, Georgios; Kristiansen, Jørgen K.

    2009-01-01

    soybean oil (ESBO) with regard to their migration from three different types of poly(vinyl chloride) into isooctane at 20, 40, and 60 degrees C. Diffusion coefficients derived from the experimental migration data were evaluated against diffusion coefficients estimated from a model based solely...

  19. Structure of chlorinated poly(vinyl chloride). III. Preparation of poly(vinyl chloride)-β,β-d2 as a model for the study of the mechanism of chlorination and of the chlorinated poly(vinyl chloride) structure

    International Nuclear Information System (INIS)

    Lukas, R.; Kolinsky, M.

    1976-01-01

    A method for the preparation of poly(vinyl chloride)-β,β-d 2 (PVC-β,β-d 2 ) as a model for the investigation of the mechanism of chlorination and of the CPVC structure has been suggested. The conditions of preparation of deuterated intermediates of a multistage synthesis of vinyl chloride-β,β-d 2 and of suspension-polymerized PVC-β,β-d 2 have been described including the mass balance. Malonic acid was used as the starting compound. Tacticity values of a sample of PVC-β,β-d 2 and its infrared and nuclear magnetic resonance (NMR) spectra are presented and compared with the data already published

  20. Histogenesis of mouse sarcomas induced by implantation of polyvinyl chloride film in radiation chimeras

    International Nuclear Information System (INIS)

    Mojzhess, T.G.; Prigozhina, E.L.

    1976-01-01

    Sarcomas were induced in CBA/CBA-T6T6 mouse radiation chimeras by implantation of polyvinyl chloride film subcutaneously 13 months after irradiation and injection of donor's bone marrow. Of the 12 tumors studied 11 had the recipient's karyotype and one the donor's. The formation of connective-tissue cells from bone-marrow precursors thus, evidently does not play an essential role in the histogenesis of sarcomas induced by plastics

  1. Preparation of Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) Material and its Application to Electrochemical Degradation of Methylene Blue in Sodium Chloride Solution

    Science.gov (United States)

    Riyanto; Prawidha, A. D.

    2018-01-01

    Electrochemical degradation of methylene blue using Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) electrode in sodium chloride have been done. The aim of this work was to degradation of methylene blue using Carbon-Chitosan-Polyvinyl Chloride (CC-PVC). Carbon chitosan composite electrode was preparing by Carbon and Chitosan powder and PVC in 4 mL tetrahydrofuran (THF) solvent and swirled flatly to homogeneous followed by drying in an oven at 100 °C for 3 h. The mixture was placed in stainless steel mould and pressed at 10 ton/cm2. Sodium chloride was used electrolyte solution. The effects of the current and electrolysis time were investigated using spectrophotometer UV-Visible. The experimental results showed that the carbon-chitosan composite electrode have higher effect in the electrochemical degradation of methylene blue in sodium chloride. Based on UV-visible spectra analysis shows current and electrolysis time has high effect to degradation of methylene blue in sodium chloride. Chitosan and polyvinyl chloride can strengthen the bond between the carbons so that the material has the high stability and conductivity. As conclusions is Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) electrode have a high electrochemical activity for degradation of methylene blue in sodium chloride.

  2. Water vapor permeation and dehumidification performance of poly(vinyl alcohol)/lithium chloride composite membranes

    KAUST Repository

    Bui, Duc Thuan

    2015-10-09

    Thin and robust composite membranes comprising stainless steel scaffold, fine and porous TiO2 and polyvinyl alcohol/lithium chloride were fabricated and studied for air dehumidification application. Higher hydrophilicity, sorption and permeation were observed for membranes with increased lithium chloride content up to 50%. The permeation and sorption properties of the membranes were investigated under different temperatures. The results provided a deeper insight into the membrane water vapor permeation process. It was specifically noted that lithium chloride significantly reduces water diffusion energy barrier, resulting in the change of permeation energy from positive to negative values. Higher water vapor permeance was observed for the membrane with higher LiCl content at lower temperature. The isothermal air dehumidification tests show that the membrane is suitable for dehumidifying air in high humid condition. Additionally, results also indicate a trade-off between the humidity ratio drop with the water vapor removal rate when varying air flowrate.

  3. Chemical leucoderma induced by ear-ring stoppers made of polyvinyl chloride

    Directory of Open Access Journals (Sweden)

    Reena Sharma

    2012-01-01

    Full Text Available We report a case of chemical leucoderma (CL in a 15-year-old girl, who developed patterned depigmentation at the back of both ear lobules after contact with plastic ear-ring stoppers made of polyvinyl chloride (PVC after continuous use for 6-7 months. Patch test with Indian standard series and cosmetic series was negative after 48 h, but she refused patch testing for extended duration as the possibility of induced depigmentation at the test site was unacceptable to her. To the best of our knowledge, this is the first report of plastic ear-ring stopper induced CL.

  4. The effect of plasticiser on the properties of radiation crosslinked poly(vinyl chloride)

    International Nuclear Information System (INIS)

    Jamaliah Shariff; Roslin Abu Bakar

    1996-01-01

    A study on the effects of plasticizers in the crosslinking of poly(vinyl chloride), PVC, by an electron beam irradiation was carried out. Different types of plasticizers were used and these, with other additives, were blended with PVC in a Brabender mixer. The blended compound was the irradiated with high energy electron beam. Subsequent analysis of its properties showed that the efficiency of crosslinking was better in the presence of the adipate and trimellitate. The tensile and elongation properties were acceptable. The ageing properties of the compounds with adipate and trimellitate-type plasticizers showed encouraging results

  5. A high dose dosimeter based polyvinyl chloride dyed with malachite green

    International Nuclear Information System (INIS)

    Kattan, M.; Daher, Y.; Alkassiri, H.

    2007-01-01

    Polyvinyl chloride film (PVC) dyed with malachite green has been studied for high dose radiation dosimetry using visible spectrophotometry. A linear relationship between the relative absorbance and the absorbed dose at the wavelength 628 nm in the range of 0-125 kGy was found. The effect of dose rate, irradiation temperature, film thickness and dye intensity were found not to influence the response. The effects of shelf-life and the post-irradiation storage in darkness and indirect daylight conditions on dosimetry performance were discussed. (author)

  6. The use of polyvinyl chloride dyed with bromo cresol purple in radiation dosimetry

    International Nuclear Information System (INIS)

    Kattan, M.; Al-Kassiri, H.; Daher, Y.

    2010-09-01

    In this work,the use of polyvinyl chloride (PVC) dyed with Bromo cresol purple in high dose radiation dosimetry has been studied according to the radio chromic change using visible spectrophotometry. The results show linear relationship between the relative absorbance (response) and the absorbed dose at the wavelength 417 nm in the range of 0-50 kGy. Dose rate, irradiation temperature, dye intensity have been investigated and found to be independent of the response. The effects of post-irradiation storage in dark and indirect daylight conditions on dosimetry performance are discussed. (Author)

  7. Poly(vinyl chloride-grafted multi-walled carbon nanotubes via Friedel-Crafts alkylation

    Directory of Open Access Journals (Sweden)

    2010-11-01

    Full Text Available A novel approach was developed for the surface modification of the multi-walled carbon nanotubes (MWCNTs with high percentage of grafting (PG% by the grafting of polymer via the Friedel-Crafts alkylation. The graft reaction conditions, such as the amount of catalyst added, the reaction temperature, and the reaction time were optimized for the Friedel-Crafts alkylation of the MWCNTs with poly(vinyl chloride (PVC with anhydrous aluminum chloride (AlCl3 as catalyst in chloroform (CHCl3. The Fourier Transform Infrared (FT-IR, Raman, and thermogravimetric (TGA analysis showed that PVC had been successfully grafted onto MWCNTs both at the ends and on the sidewalls by the proposed Friedel-Crafts alkylation. The PVC grafted MWCNTs (PVC-MWCNTs could be dispersed well in organic solvent and the dispersion was more stable.

  8. Influence of acrylonitrile butadiene rubber on recyclability of blends prepared from poly(vinyl chloride) and poly(methyl methacrylate).

    Science.gov (United States)

    Suresh, Sunil S; Mohanty, Smita; Nayak, Sanjay K

    2018-06-01

    The current investigation deals with the recycling possibilities of poly(vinyl chloride) and poly(methyl methacrylate) in the presence of acrylonitrile butadiene rubber. Recycled blends of poly(vinyl chloride)/poly(methyl methacrylate) are successfully formed from the plastic constituents, those are recovered from waste computer products. However, lower impact performance of the blend and lower stability of the poly(vinyl chloride) phase in the recycled blend restricts its further usage in industrial purposes. Therefore, effective utilisation acrylonitrile butadiene rubber in a recycled blend was considered for improving mechanical and thermal performance. Incorporation of acrylonitrile butadiene rubber resulted in the improvement in impact performance as well as elongation-at-break of the recycled blend. The optimum impact performance was found in the blend with 9 wt% acrylonitrile butadiene rubber, which shows 363% of enhancement as compared with its parent blend. Moreover, incorporated acrylonitrile butadiene rubber also stabilises the poly(vinyl chloride) phase present in the recycled blend, similarly Fourier transform infrared spectroscopy studies indicate the interactions of various functionalities present in the recycled blend and acrylonitrile butadiene rubber. In addition to this, thermogravimetric analysis indicates the improvement in the thermal stability of the recycled blend after the addition of acrylonitrile butadiene rubber into it. The existence of partial miscibility in the recycled blend was identified using differential scanning calorimetry and scanning electron microscopy.

  9. Analysis of phthalate ester content in poly(vinyl chloride) plastics by means of Fourier transform Raman spectroscopy

    DEFF Research Database (Denmark)

    Nørbygaard, Thomas; Berg, Rolf W.

    2004-01-01

    Fourier transform (FT) Raman spectroscopy is applied to a range of phthalate ester plasticizers in pure form as well as in poly(vinyl chloride) (PVC) samples. It is found that phthalate esters as a group can be identified by a set of six characteristic Raman bands. FT-Raman spectra of 22 phthalate...

  10. Preparation of anion exchange membrane using polyvinyl chloride (PVC) for alkaline water electrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Gab-Jin; Bong, Soo-Yeon; Ryu, Cheol-Hwi [Hoseo University, Asan (Korea, Republic of); Lim, Soo-Gon [Energy and Machinery Korea Co., Ltd., Changwon (Korea, Republic of); Choi, Ho-Sang [Kyungil University, Gyeongsan (Korea, Republic of)

    2015-09-15

    An anion exchange membrane was prepared by the chloromethylation and the amination of polyvinyl chloride (PVC), as the base polymer. The membrane properties of the prepared anion exchange membrane, including ionic conductivity, ion exchange capacity, and water content were measured. The ionic conductivity of the prepared anion exchange membrane was in the range of 0.098x10{sup -2} -7.0x10{sup -2}S cm{sup -1}. The ranges of ion exchange capacity and water content were 1.9-3.7meq./g-dry-membrane and 35.1-63.1%, respectively. The chemical stability of the prepared anion exchange membrane was tested by soaking in 30 wt% KOH solution to determine its availability as a separator in the alkaline water electrolysis. The ionic conductivity during the chemical stability test largely did not change.

  11. Interaction between vegetable oil based plasticizer molecules and polyvinyl chloride, and their plasticization effect

    Science.gov (United States)

    Haryono, Agus; Triwulandari, Evi; Jiang, Pingping

    2017-01-01

    Plasticizer molecules are low molecular weight compounds that are widely used in polymer industries especially in polyvinyl chloride (PVC) resin. As an additive in PVC resin, the important role of plasticizer molecules is to improve the flexibility and processability of PVC by lowering the glass transition temperature (Tg). However, the commercial plasticizer like di(2-ethylhexyl)phthalate (DEHP) is known to cause liver cancer, at least in laboratory rats. DEHP can leach out from PVC into blood, certain drug solutions and fatty foods, which has been detected in the bloodstream of patients undergoing transfusion. Vegetable oil based plasticizers have some attractive properties such as non-toxic, bio-degradable, good heat and light stability, renewable resources, and environmentally friendly. Here we discussed the main results and development of vegetable oil based plasticizer, and especially palm oil based plasticizer. The interaction between plasticizer and polymer was discussed from the properties of the plasticized polymeric material.

  12. Improving the Healthiness of Sustainable Construction: Example of Polyvinyl Chloride (PVC

    Directory of Open Access Journals (Sweden)

    Emina Kristina Petrović

    2018-02-01

    Full Text Available With the increasing emphasis on sustainable construction, it has become important to better understand the impacts of common materials. This is especially paramount with the introduction of the United Nations (UN Sustainable Development Goals (SDGs which call for more comprehensive evaluations, adding many aspects of social consideration to the issues of environmental sustainability, including human health. Polyvinyl chloride (PVC/vinyl can be seen as a material with potential for significant adverse effects on a multiplicity of levels, and the construction industry is its single most significant consumer. This article presents a transdisciplinary review of adverse health impacts associated with PVC showing a number of issues: some that could be eliminated through design, but also some which appear inherent to the material itself and therefore unavoidable. The totality of issues revealed in relation to PVC presents a compelling case for a call for complete elimination of use of this material in sustainable construction.

  13. Effect of gamma radiation on the spectroscopic properties of Bromocresol green-polyvinyl chloride film

    International Nuclear Information System (INIS)

    Bera, Anuradha; Ram, Surendra; Singh, Shailendra K.; Vaijapurkar, S.G.

    2009-01-01

    Bromocresol Green (BCG) - Polyvinyl chloride (PVC) film was prepared by dispersing the dye in the polymer matrix in a suitable solvent medium in the presence of an organic base and then solvent casting the formulation in the form of transparent colored film. Preliminary studies through UV-Vis Spectroscopic measurements show that the prepared PVC - dye films was sensitive to gamma radiation almost linearly in the dose range upto 8 kGy range. This spectroscopic change becomes visually distinguishable from 4 kGy onwards until 8 kGy where it finally changes color from green to yellow, beyond which no significant optical change was observed. The gamma response of the film could be tailored by varying the concentration of the pH sensitive dye and the organic base. (author)

  14. Model fire tests on polyphosphazene rubber and polyvinyl chloride (PVC)/nitrile rubber foams

    Science.gov (United States)

    Widenor, W. M.

    1978-01-01

    A video tape record of model room fire tests was shown, comparing polyphosphazene (P-N) rubber and polyvinyl chloride (PVC)/nitrile rubber closed-cell foams as interior finish thermal insulation under conditions directly translatable to an actual fire situation. Flashover did not occur with the P-N foam and only moderate amounts of low density smoke were formed, whereas with the PVC/nitrile foam, flashover occurred quickly and large volumes of high density smoke were emitted. The P-N foam was produced in a pilot plant under carefully controlled conditions. The PVC/nitrile foam was a commercial product. A major phase of the overall program involved fire tests on P-N open-cell foam cushioning.

  15. Fast neutron irradiation induced changes in the optical and thermal properties of modified polyvinyl chloride

    Energy Technology Data Exchange (ETDEWEB)

    Abou Taleb, W.M. [Alexandria Univ. (Egypt); Madi, N.K.; Kassem, M.E.; El-Khatib, A.M. [Alexandria Univ. (Egypt). Dept. of Physics

    1996-05-01

    The effect of both dopant and neutron radiation on the optical and thermal properties of polyvinyl chloride (PVC) has been studied. The doped samples with Pb and Cd were irradiated with a 14 MeV-neutron fluence in the range 7-28.8 x 10{sup 9} n/cm{sup 2}. The optical energy gap E{sub op} exhibits a significant dependence on the type of additive and the neutron irradiation fluence. The specific heat at constant pressure C{sub p} showed a nonmonotonical change with radiation fluence. The results of this study show that PVC:Pb behaves as a crystalline structure which is only slightly affected by neutron irradiation, while PVC:Cd is highly affected. (author).

  16. Fast neutron irradiation induced changes in the optical and thermal properties of modified polyvinyl chloride

    International Nuclear Information System (INIS)

    Abou Taleb, W.M.; Madi, N.K.; Kassem, M.E.; El-Khatib, A.M.

    1996-01-01

    The effect of both dopant and neutron radiation on the optical and thermal properties of polyvinyl chloride (PVC) has been studied. The doped samples with Pb and Cd were irradiated with a 14 MeV-neutron fluence in the range 7-28.8 x 10 9 n/cm 2 . The optical energy gap E op exhibits a significant dependence on the type of additive and the neutron irradiation fluence. The specific heat at constant pressure C p showed a nonmonotonical change with radiation fluence. The results of this study show that PVC:Pb behaves as a crystalline structure which is only slightly affected by neutron irradiation, while PVC:Cd is highly affected. (author)

  17. Novel thermally stable poly(vinyl chloride) composites for sulfate removal

    Energy Technology Data Exchange (ETDEWEB)

    Nadagouda, Mallikarjuna N., E-mail: Nadagouda.mallikarjuna@epa.gov [Water Supply and Water Resources Division, National Risk Management Research Laboratory U.S. Environmental Protection Agency, 26 W. Martin Luther King Drive Cincinnati, Ohio 45268 (United States); Pressman, Jonathan; White, Colin; Speth, Thomas F.; McCurry, Daniel L. [Water Supply and Water Resources Division, National Risk Management Research Laboratory U.S. Environmental Protection Agency, 26 W. Martin Luther King Drive Cincinnati, Ohio 45268 (United States)

    2011-04-15

    Graphical abstract: Barium carbonate and/or barium carbonate-loaded silica aero-gels dispersed polyvinyl chloride (PVC) composites were prepared by dissolving PVC in tetrahydrofuran (THF), dispersing BaCO{sub 3} and/or BaCO{sub 3}-loaded silica aero-gels, re-precipitating the PVC with water at room temperature. The PVC composites were then characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray mapping, X-ray diffraction (XRD), thermogravimetric analysis (TGA) and inductively coupled plasma mass spectrometry (ICP-MS) analysis. The obtained composites had better thermal properties than the control PVC. The composites were tested for sulfate removal and found to significantly reduce sulfate when compared with control PVC. - Abstract: BaCO{sub 3} dispersed PVC composites were prepared through a polymer re-precipitation method. The composites were tested for sulfate removal using rapid small scale column test (RSSCT) and found to significantly reduce sulfate concentration. The method was extended to synthesize barium carbonate-loaded silica aero-gels-polyvinyl chloride (PVC) polymer composites. The PVC composites were characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray mapping, X-ray diffraction (XRD), thermogravimetric analysis (TGA) and inductively coupled plasma mass spectrometry (ICP-MS) analysis. The method has advantages over conventional sulfate precipitation (sulfate removal process) using BaCO{sub 3} wherein clogging of the filter can be avoided. The method is environmentally friendly and does not interfere with natural organic matter as the conventional resin does. Some of the composites were thermally more stable as compared with the pure PVC discussed in the literature.

  18. Novel thermally stable poly(vinyl chloride) composites for sulfate removal

    International Nuclear Information System (INIS)

    Nadagouda, Mallikarjuna N.; Pressman, Jonathan; White, Colin; Speth, Thomas F.; McCurry, Daniel L.

    2011-01-01

    Graphical abstract: Barium carbonate and/or barium carbonate-loaded silica aero-gels dispersed polyvinyl chloride (PVC) composites were prepared by dissolving PVC in tetrahydrofuran (THF), dispersing BaCO 3 and/or BaCO 3 -loaded silica aero-gels, re-precipitating the PVC with water at room temperature. The PVC composites were then characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray mapping, X-ray diffraction (XRD), thermogravimetric analysis (TGA) and inductively coupled plasma mass spectrometry (ICP-MS) analysis. The obtained composites had better thermal properties than the control PVC. The composites were tested for sulfate removal and found to significantly reduce sulfate when compared with control PVC. - Abstract: BaCO 3 dispersed PVC composites were prepared through a polymer re-precipitation method. The composites were tested for sulfate removal using rapid small scale column test (RSSCT) and found to significantly reduce sulfate concentration. The method was extended to synthesize barium carbonate-loaded silica aero-gels-polyvinyl chloride (PVC) polymer composites. The PVC composites were characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray mapping, X-ray diffraction (XRD), thermogravimetric analysis (TGA) and inductively coupled plasma mass spectrometry (ICP-MS) analysis. The method has advantages over conventional sulfate precipitation (sulfate removal process) using BaCO 3 wherein clogging of the filter can be avoided. The method is environmentally friendly and does not interfere with natural organic matter as the conventional resin does. Some of the composites were thermally more stable as compared with the pure PVC discussed in the literature.

  19. [Simultaneous determination of ten organotin compounds in polyvinyl chloride plastics using gas chromatography-mass spectrometry].

    Science.gov (United States)

    Li, Ying; Li, Bin; Liu, Li; Zhang, Chen; Wu, Jingwu; Liu, Zhihong; Li, Xintian

    2009-01-01

    A rapid and effective gas chromatography coupled with mass spectrometry method has been developed systematically and studied for the simultaneous determination of 10 organotin compounds, dibutyltin-dichloride (DBT), n-butyltin-trichloride (MBT), triethyltinchloride (TET), fentin-chloride (TPhT), chlorotributylstannane (TBT), tri-n-propyltinchloride (TPrT), diphenyltin-dichloride (DPhT), tetrabutyltin (TeBT), di-n-octyltin-dichloride (DOT), phenyltin trichloride (MPhT)), in polyvinyl chloride (PVC) plastics. The PVC sample was dissolved with tetrahydrofuran and the polymer in the sample was precipitated with methanol, and then the target compounds were derivatized with sodium tetraethylborate and extracted with hexane under ultrasonication. The qualitative and quantitative analysis were carried out by GC-MS and the total ion chromatogram and selected ion chromatogram were obtained. The derivatization and extraction conditions, such as the derivatization time, derivatization pH value, dosages of derivatization reagent and precipitation reagent were optimized. The good linearities, recoveries and precisions were obtained. The linearity ranges were 0.5 - 50 mg/L. The linearity correlation coefficients of 10 organotin compounds were between 0.997 8 and 0.999 7. The average recoveries were 84.23% - 109.1% with relative standard deviations of 4.24% - 10.75%. The established method has been successfully applied to the determination of organotin compounds in PVC plastics.

  20. Recycling of spent lithium-ion battery with polyvinyl chloride by mechanochemical process.

    Science.gov (United States)

    Wang, Meng-Meng; Zhang, Cong-Cong; Zhang, Fu-Shen

    2017-09-01

    In the present study, cathode materials (C/LiCoO 2 ) of spent lithium-ion batteries (LIBs) and waste polyvinyl chloride (PVC) were co-processed via an innovative mechanochemical method, i.e. LiCoO 2 /PVC/Fe was co-grinded followed by water-leaching. This procedure generated recoverable LiCl from Li by the dechlorination of PVC and also generated magnetic CoFe 4 O 6 from Co. The effects of different additives (e.g. alkali metals, non-metal oxides, and zero-valent metals) on (i) the conversion rates of Li and Co and (ii) the dechlorination rate of PVC were investigated, and the reaction mechanisms were explored. It was found that the chlorine atoms in PVC were mechanochemically transformed into chloride ions that bound to the Li in LiCoO 2 to form LiCl. This resulted in reorganization of the Co and Fe crystals to form the magnetic material CoFe 4 O 6 . This study provides a more environmentally-friendly, economical, and straightforward approach for the recycling of spent LIBs and waste PVC compared to traditional processes. Copyright © 2017. Published by Elsevier Ltd.

  1. Sorption of amiodarone to polyvinyl chloride infusion bags and administration sets.

    Science.gov (United States)

    Weir, S J; Myers, V A; Bengtson, K D; Ueda, C T

    1985-12-01

    The loss of amiodarone from i.v. admixtures to flexible polyvinyl chloride (PVC) infusion bags and i.v. administration sets was studied. Admixtures containing amiodarone hydrochloride 600 micrograms/mL and either 5% dextrose injection or 0.9% sodium chloride injection were stored at room temperature in glass bottles (both with and without contact of the drug solution with the rubber bottle closure), in flexible PVC bags, or in rigid PVC bottles. After 120 hours, the contents of each flexible PVC bag were emptied and replaced by methanol, which was allowed to remain in the bag for an additional 120 hours and was then analyzed for amiodarone content. To determine availability of amiodarone after infusion through a 1.8-m PVC i.v. administration set, solutions stored in glass containers were run through the set at 0.5 mL/min for 90 minutes. Samples of drug solutions were collected at appropriate intervals and analyzed by a stability-indicating high-performance liquid chromatography (HPLC) assay. Admixtures containing 0.9% sodium chloride injection were not stable; visual incompatibility was evident after 24 hours of storage in glass bottles, and no further testing was performed. In admixtures containing 5% dextrose injection that were stored in 50-mL flexible PVC bags, 60% of the initial amiodarone concentration remained after 120 hours; approximately half of the lost drug was recovered with the methanol. In effluent collected from the PVC administration set, 82% of the initial amiodarone concentration remained. Amiodarone concentrations did not decrease appreciably, after storage in glass or rigid PVC bottles, indicating that drug loss was probably affected by the plasticizer, di-2-ethylhexyl phthalate.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Electrical and spectroscopic characterization of polyaniline-polyvinyl chloride (PANI-PVC) blends doped with sodium thiosulphate

    International Nuclear Information System (INIS)

    Ameen, Sadia; Ali, Vazid; Zulfequar, M.; Mazharul Haq, M.; Husain, M.

    2008-01-01

    Polyaniline is doped with sodium thiosulphate in aqueous tetrahydrofuran (THF) and the blended films have been prepared by changing the amount of doped polyaniline (PANI) in the fixed amount of polyvinyl chloride (PVC). The electrical conductivity of various samples of polyaniline-polyvinyl chloride (PANI-PVC) blends has been studied to see the effect of dopant in the temperature range 300-400 K. Mott's parameters are used to explain the conduction mechanism. Different parameters such as pre-exponential factor (σ 0 ), activation energy (ΔE) and T 0 have also been calculated to see the effect of chemical doping. The crystallinity of the blends is explained on the basis of T 0 . The calculated values of T 0 show that crystallinity increases with an increase of doped PANI in PANI-PVC blends. Fourier transform-infrared (FTIR) spectroscopy is done to explore the nature and interaction of dopant into the polymeric chain

  3. Stability of 2 mg/mL Adenosine Solution in Polyvinyl Chloride and Polyolefin Infusion Bags.

    Science.gov (United States)

    DeAngelis, Michael; Ferrara, Alexander; Gregory, Kaleigh; Zammit, Kimberly; Zhao, Fang

    2018-04-01

    Adenosine is a potent endogenous mediator of vasodilation. Compounded sterile solutions of adenosine are used in cardiac catheterization lab to perform stress tests on the heart. These tests are used to determine the fractional flow reserve (FFR) and are commonly used in the management and diagnosis of cardiovascular conditions. The purpose of this study was to assess the physical and chemical stability of 2 mg/mL adenosine in 0.9% Sodium Chloride Injection, USP in polyvinyl chloride [PVC]) and polyolefin infusion bags stored at room temperature (20°C-25°C) and under refrigeration (2°C-8°C). The compounding and analytical methods used in this study were very similar to those described in the prior publications from the authors' laboratory. To ensure a uniform starting concentration of all stability samples, a batch of 2 mg/mL adenosine solution was prepared and then packaged into empty PVC and polyolefin infusion bags. These stability samples were prepared in triplicate for each bag type and storage temperature (a total of 12 samples). The infusion bag samples were assessed for stability immediately after preparation and after 1 day, 3 days, 7 days, and 14 days. At each time point, the infusion bags were first visually inspected against a light background for color change, clarity, and particulates. Aliquots were drawn from each sample at each time point for pH analysis and high-performance liquid chromatography (HPLC) analysis. Over 14 days of storage at room temperature or refrigeration, no considerable change in visual appearance or pH was observed in any bags. All samples retained 90% to 110% of the initial drug concentration. No significant degradation peaks were observed in the HPLC chromatograms.

  4. Chemically Modified Polyvinyl Chloride for Removal of Thionine Dye (Lauth’s Violet

    Directory of Open Access Journals (Sweden)

    Helena Ma A. M. M. S. Ali

    2017-11-01

    Full Text Available The chemical modification of hydrophobic polymer matrices is an alternative way to elchange their surface properties. The introduction of sulfonic groups in the polymer changes the surface properties such as adhesion, wettability, catalytic ability, and adsorption capacity. This work describes the production and application of chemically modified polyvinyl chloride (PVC as adsorbent for dyes removal. Chemical modification of PVC was evaluated by infrared spectroscopy and elemental analysis, which indicated the presence of sulfonic groups on PVC. The chemically modified PVC (PVCDS showed an ion exchange capacity of 1.03 mmol−1, and efficiently removed the thionine dye (Lauth’s violet from aqueous solutions, reaching equilibrium in 30 min. The adsorption kinetics was better adjusted for a pseudo second order model. This result indicates that the adsorption of thionine onto PVCDS occurs by chemisorption. Among the models for the state of equilibrium, SIPS and Langmuir exhibited the best fit to the experimental results and PVCDS showed high adsorption capacities (370 mg−1. Thus, it is assumed that the system presents homogeneous characteristics to the distribution of active sites. The modification promoted the formation of surface characteristics favorable to the dye adsorption by the polymer.

  5. Degradation of polyvinyl chloride (PVC) / hydrolyzed collagen (HC) blends active sludge test.

    Science.gov (United States)

    Agafiţei, Gabriela-Elena; Pascu, Mihaela; Cazacu, Georgeta; Vasile, Cornelia

    2008-01-01

    Biodegradable polymers represent a solution for the environment protection: they decrease the landfill space, by declining the petrochemical sources, and offer also an alternative solution for the recycling. The behavior during degradation in the presence of active sludge of some polyvinyl chloride (PVC) based blends with variable content of hydrolyzed collagen (HC) has been followed. Some samples were subjected to UV irradiation, for 30 hours. The modifications induced in the environment by the polymer systems (pH variation, bacterial composition), as well as the changes of the properties of the blends (weight losses, aspect etc.) were studied. During the first moments of degradation in active sludge, all the samples absorbed water, behavior which favored the biodegradation. The bacteriological analysis of the sludge indicates the presence of some microbiological species. Generally, the populations of microorganisms decrease, excepting the sulphito-reducing anaerobic bacteria, the actinomycetes and other anaerobic bacteria. PVC/HC blends are degraded with a significant rate in active sewage sludge. More susceptible for the degradation are the UV irradiated blends. After the migration of the components with a small molecular mass in the environment, the natural polymer is degraded. The degradation effect increases with the content in the natural polymer.

  6. Thermal stabilization and plasticization of poly(vinyl chloride) by ester thiols: Update and current status

    International Nuclear Information System (INIS)

    Starnes, William H.; Du, Bin; Kim, Soungkyoo; Zaikov, Vadim G.; Ge, Xianlong; Culyba, Elizabeth K.

    2006-01-01

    Poly(vinyl chloride) (PVC) is one of the most important medical plastics. Recently, however, the safety of flexible PVC containing the common plasticizer, di(2-ethylhexyl) phthalate, has been called into question. Widely used heat stabilizers for PVC that incorporate toxic heavy metals also have fallen into disfavor. In order to address these problems, we have synthesized and tested, as potential replacements, several organic thiols that contain one or more carboxylate ester functions and thus are highly compatible with the polymer. When introduced into PVC at high loading levels (e.g., 30-35 parts by weight), the ester thiols are extremely effective as heat stabilizers and also useful as primary plasticizers. When used at a low loading level (e.g., 3 parts by weight), they still are excellent heat stabilizers for both plasticized and rigid PVC. Importantly, their high potency is achieved in the absence of any costabilizers that incorporate heavy metals. Their syntheses are simple and straightforward, and their odors are not offensive, because their volatilities are low. Described here are some typical results obtained with this new additive technology, which was licensed for commercialization in 2005

  7. Flotation separation of polyvinyl chloride and polyethylene terephthalate plastics combined with surface modification for recycling.

    Science.gov (United States)

    Wang, Chongqing; Wang, Hui; Fu, Jiangang; Zhang, Lingling; Luo, Chengcheng; Liu, Younian

    2015-11-01

    Surface modification with potassium permanganate (KMnO4) solution was developed for separation of polyvinyl chloride (PVC) and polyethylene terephthalate (PET) waste plastics. The floatability of PVC decreases with increasing of KMnO4 concentration, treatment time, temperature and stirring rate, while that of PET is unaffected. Fourier transform infrared (FT-IR) analysis confirms that mechanism of surface modification may be due to oxidization reactions occurred on PVC surface. The optimum conditions are KMnO4 concentration 1.25 mM/L, treatment time 50 min, temperature 60°C, stirring rate 300 r/min, frother concentration 17.5 g/L and flotation time 1 min. PVC and PET with different particle sizes were separated efficiently through two-stage flotation. Additionally, after ultrasonic assisted surface modification, separation of PVC and PET with different mass ratios was obtained efficiently through one-stage flotation. The purity and the recovery of the obtained products after flotation separation are up to 99.30% and 99.73%, respectively. A flotation process was designed for flotation separation of PVC and PET plastics combined with surface modification. This study provides technical insights into physical separation of plastic wastes for recycling industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Case report of occupational asthma induced by polyvinyl chloride and nickel.

    Science.gov (United States)

    Song, Ga-Won; Ban, Ga-Young; Nam, Young-Hee; Park, Hae-Sim; Ye, Young-Min

    2013-10-01

    Polyvinyl chloride (PVC) is a widely used chemical for production of plastics. However occupational asthma (OA) caused by PVC has been reported only rarely. We report a 34-yr-old male wallpaper factory worker with OA due to PVC and nickel (Ni) whose job was mixing PVC with plasticizers. He visited the emergency room due to an asthma attack with moderate airflow obstruction and markedly increased sputum eosinophil numbers. A methacholine challenge test was positive (PC20 2.5 mg/mL). Bronchoprovocation tests with both PVC and Ni showed early and late asthmatic responses, respectively. Moreover, the fractional concentration of exhaled nitric oxide (FeNO) was increased after challenge with PVC. To our knowledge, this is the first case of OA in Korea induced by exposure to both PVC and Ni. We suggest that eosinophilic inflammation may be involved in the pathogenesis of PVC-induced OA and that FeNO monitoring can be used for its diagnosis.

  9. Viscoelastic, Spectroscopic, and Microscopic Characterization of Novel Bio-Based Plasticized Poly(vinyl chloride Compound

    Directory of Open Access Journals (Sweden)

    Mei Chan Sin

    2014-01-01

    Full Text Available Plasticized poly(vinyl chloride (PVC is one of the most widely consumed commodity plastics. Nevertheless, the commonly used plasticizers, particularly phthalates, are found to be detrimental to the environment and human health. This study aimed to investigate the ability of an alternative greener material, medium-chain-length polyhydroxyalkanoates (mcl-PHA, a kind of biopolyester and its thermally degraded oligoesters, to act as a compatible bioplasticizer for PVC. In this study, mcl-PHA were synthesized by Pseudomonas putida PGA1 in shake flask fermentation using saponified palm kernel oil (SPKO and subsequently moderately thermodegraded to low molecular weight oligoesters (degPHA. SEM, ATR-FTIR, 1H-NMR, and DMA were conducted to study the film morphology, microstructure, miscibility, and viscoelastic properties of the PVC-PHA and PVC/degPHA binary blends. Increased height and sharpness of tan δmax⁡ peak for all binary blends reveal an increase in chain mobility in the PVC matrix and high miscibility within the system. The PVC-PHA miscibility is possibly due to the presence of specific interactions between chlorines of PVC with the C=O group of PHA as evidenced by spectroscopic analyses. Dynamic viscoelastic measurements also showed that mcl-PHA and their oligoesters could reduce the Tg of PVC, imparting elasticity to the PVC compounds and decreasing the stiffness of PVC.

  10. Positron Annihilation Lifetime Study of Pure and Doped Polyvinyl Chloride with Al2O3

    International Nuclear Information System (INIS)

    Abdel-Hady, E.E.; Hamdy, F. M. M.; Alaa, H.B.

    2005-01-01

    Positron annihilation lifetime of pure and doped polyvinyl chloride (PVC) with Al 2 O 3 reflect the effect of concentration as well as temperature on free volume. Therefore, variations of the ortho-positronium (o-Ps) lifetime and its intensity have been correlated with changes in the dielectric properties of the pure and doped PVC. The o-Ps lifetime and its intensity show a linear dependence with a discontinuity at 20 % concentration of Al 2 O 3 . The size and the fractional of the o-Ps hole volume were estimated from the positron annihilation parameters. Therefore, the temperature dependence of the electrical conductivity and the positron annihilation parameters on pure and doped PVC with 20 % Al 2 O 3 were studied in the range from 20 to 140 degree C. The shift of the glass transition temperature to lower temperature for the 20 % Al 2 O 3 doped PVC might explain the increase in the electrical conductivity with the concentration of the additive

  11. Radiation grafting of hydrophilic monomers on to plasticized poly(vinyl chloride) sheets: Pt. 1

    International Nuclear Information System (INIS)

    Kalliyana Krishnan, V.; Jayakrishnan, A.; Francis, J.D.

    1990-01-01

    Medical-grade plasticized polyvinyl chloride (PVC) sheets were surface modified using gamma-radiation grafting of a combination of hydrophilic monomers based on 2-hydroxyethyl methacrylate (HEMA) and N-vinyl pyrrolidone (NVP). The properties of the modified surfaces were evaluated using contact angle measurements, phase-contrast photomicroscopy and scanning electron microscopy. Surface energy calculations indicated that the surfaces became highly hydrophilic when grafted with even a 1% (v/v) solution of HEMA-NVP combination in the presence of 0.005 M CuSO 4 . Migration of the plasticizer di(2-ethylhexyl phthalate) from the grafted sheets was examined in hydrocarbon solvents such as n-hexane, n-heptane and n-octane and in extractant media such as cotton seed oil and polyethylene glycol-400 (PEG-400). The migration was found to be 0 C over a period of 5 h. Accelerated leaching studies in cotton seed oil and PEG-400 demonstrated that virtually no plasticizer migrated out in the former over a period of 96 h whereas the rate of migration in the latter medium showed only a mild reduction. The migration behaviour was Fickian in nature for grafted sheets. The method described may be useful as a simple, versatile technique for preventing plasticizer migration from plasticized PVC for medical applications. (author)

  12. Degradation of poly(vinyl chloride) films by X-rays radiation

    International Nuclear Information System (INIS)

    Sbampato, M.E.; Kawano, Y.

    1984-01-01

    The degradation of pure poly(vinyl chloride) (PVC) films has been studied by X-rays radiation in vacuum. The films are transparent and become yellow with the exposure of radiation and this colour is enhanced with the time of irradiation. The infrared, ultraviolet and visible spectra changed in the irradiated material. The IR spectra show changes in itensities and band shifting, particularly in the region of C-Cl stretching vibrations indicating the occurrence of dehydrochlorination and a change in the conformation of the degraded PVC. The ultraviolet and visible spectra of irradiated films show a strong absorption band at 240 nm and many shoulders which are associated to dyenes, carbonyl and polyenes with few double bonds formed. The shoulder numbers increase in the spectra of samples kept for three months. This effect indicates that with irradiation, HCl is evolved resulting in the formation of polyenyl radicals, which propagate after irradiation. At the same time, should occur the reaction of these radicals with the atmospheric oxygen with formation of C=0 bonds. (Author) [pt

  13. The production of hydrotalcite from magnesite ore as non-toxic heat stabiliser for polyvinyl chloride

    Directory of Open Access Journals (Sweden)

    J. van der Laan

    2005-09-01

    Full Text Available In recent years polyvinyl chloride (PVC processors had to submit to worldwide pressure to convert to environmentally friendly stabilisers such as hydrotalcite (HT, since most of the heat stabilisers currently in use contain heavy metals such as lead, cadmium or barium – these being highly toxic. The presently used HT production process is, however, very expensive as it involves the recovering of magnesium from seawater magnesia. The purpose of this study was to prove that it is indeed possible to produce cost effective and non-toxic HT from an alternative source. During this study the costing and heat stabilising ability of the hydrotalcite produced from magnesite was compared to that of commercially available heat stabilisers. The effect of the pre-mixing process, as well as the influence of particle size distribution was also investigated. A cost comparative and stabilising efficiency study indicated the cost effectiveness of HT produced from magnesite ore, in comparison with other commercially available stabilisers. The use of HT as produced from magnesite ore would indeed assist in the worldwide changeover to environmentally friendly stabilisers.

  14. Plasticizers increase adhesion of the deteriogenic fungus Aureobasidium pullulans to polyvinyl chloride.

    Science.gov (United States)

    Webb, J S; Van der Mei, H C; Nixon, M; Eastwood, I M; Greenhalgh, M; Read, S J; Robson, G D; Handley, P S

    1999-08-01

    Initial adhesion of fungi to plasticized polyvinyl chloride (pPVC) may determine subsequent colonization and biodeterioration processes. The deteriogenic fungus Aureobasidium pullulans was used to investigate the physicochemical nature of adhesion to both unplasticized PVC (uPVC) and pPVC containing the plasticizers dioctyl phthalate (DOP) and dioctyl adipate (DOA). A quantitative adhesion assay using image analysis identified fundamental differences in the mechanism of adhesion of A. pullulans blastospores to these substrata. Adhesion to pPVC was greater than that to uPVC by a maximum of 280% after a 4-h incubation with 10(8) blastospores ml(-1). That plasticizers enhance adhesion to PVC was confirmed by incorporating a dispersion of both DOA and DOP into the blastospore suspension. Adhesion to uPVC was increased by up to 308% in the presence of the dispersed plasticizers. Hydrophobic interactions were found to dominate adhesion to uPVC because (i) a strong positive correlation was observed between substratum hydrophobicity (measured by using a dynamic contact angle analyzer) and adhesion to a range of unplasticized polymers including uPVC, and (ii) neither the pH nor the electrolyte concentration of the suspension buffer, both of which influence electrostatic interactions, affected adhesion to uPVC. In contrast, adhesion to pPVC is principally controlled by electrostatic interactions. Enhanced adhesion to pPVC occurred despite a relative reduction of 13 degrees in the water contact angle of pPVC compared to that of uPVC. Furthermore, adhesion to pPVC was strongly dependent on both the pH and electrolyte concentration of the suspension medium, reaching maximum levels at pH 8 and with an electrolyte concentration of 10 mM NaCl. Plasticization with DOP and DOA therefore increases adhesion of A. pullulans blastospores to pPVC through an interaction mediated by electrostatic forces.

  15. Stability of Procainamide Injection in Clear Glass Vials and Polyvinyl Chloride Bags.

    Science.gov (United States)

    Donnelly, Ronald F

    2017-11-01

    The objective of this study was to evaluate the chemical stability of procainamide hydrochloride, 100 mg/mL, when repackaged in clear glass vials or diluted to 3 mg/mL with normal saline and packaged in polyvinyl chloride (PVC) bags when stored at either 23°C and exposed to light (ETL) or 5°C and protected from light (PFL). Solutions were assayed using a stability-indicating high-performance liquid chromatography method. Samples (5 mL) were collected from triplicate containers on days 0, 7, 14, 21, 28, 56, 91, and 193. Color/clarity and pH changes were also monitored at each time interval. During the study, all samples remained clear and there was only a slight pH change. The color of the solutions stored at 23°C intensified but did not correlate with a significant decrease in concentration, while solutions stored at 5°C remained unchanged. Solutions repackaged in glass vials were stable for 193 days when stored at 23ºC and ETL or 5ºC and PFL. When further diluted to 3 mg/mL with normal saline and packaged in PVC bags, procainamide was also stable for 193 days at either 23ºC and ETL or 5°C and PFL. The stability of procainamide, 100 mg/mL, repackaged in clear glass vials was 193 days when stored at either 23ºC and ETL or 5ºC or PFL. If diluted further to 3 mg/mL with normal saline and packaged in PVC bags, the drug was also stable for 193 days at either 23ºC and ETL or 5°C and PFL.

  16. Evaluation of the Utility of Recycling Used Products made of Polyvinyl Chloride

    Science.gov (United States)

    Matsuda, Satoshi; Kubota, Hiroshi

    This study intends to propose a new approach to evaluate the utility of recycling used products made of Polyvinyl Chloride (PVC) . In order to determine whether or not these used products can be recycled, there must be some indicators that appropriately and quantitatively show the degree that the contribution of recycling these targeted used products has on society. It was indicated that the rights and wrongs of incineration and/or heat recovery using a material such as wallpaper or floor cover made of PVC could be judged by the concept of "Social Energy Consumption" originally proposed by the authors (Chap. 3 in the text) . On the other hand, in the case where the used products such as PVC pipes and joints are dug out from underground and recycled, this research shows the estimation of its utility should be accomplished by extending the concept: Specifically, the manpower converted to the value of the social energy consumption was added, because labor costs for digging out these used products occupy a large portion of the total recycling cost, although manpower is not taken into account in the usual energy balance calculation, which leads to the contradiction of the estimation results from the standpoint of energy balance and economy. In this study, the marginal cost for digging out PVC pipes and joints evaluated by this method was shown as an example of a trial calculation (Chap. 2 in the text) . As a whole, this research quantitatively demonstrated an example trial calculation showing whether or not these used products should be recycled disregarding if the economic efficiency should be evaluated as a result of the analysis based upon the concept of "Social Energy Consumption".

  17. Stability of diclofenac sodium oral suspensions packaged in amber polyvinyl chloride bottles.

    Science.gov (United States)

    Donnelly, Ronald F; Pascuet, Elena; Ma, Carmen; Vaillancourt, Régis

    2010-01-01

    Prescribing of diclofenac for children usually involves a dose different from commercially available strengths. This drug is available only as tablets, which can be divided only so many times before the dose obtained becomes inaccurate. In addition, children may have difficulty swallowing tablets. For these reasons, a compounding formula for a liquid dosage form is essential to ensure effective delivery of the drug to pediatric patients. To develop a compounding formula for diclofenac sodium and to determine the extended physical and chemical stability of this compound when stored in amber polyvinyl chloride (PVC) prescription bottles under refrigeration and at room temperature. A suspension of diclofenac sodium (10 mg/mL) was prepared from commercially available diclofenac sodium tablets, with Ora-Blend as the suspending and flavouring agent. The suspension was packaged in 60-mL amber PVC prescription bottles and stored at either room temperature (23°C) or under refrigeration (5°C). Samples were collected on days 0, 7, 14, 21, 27, 56, and 93. Chemical stability was determined using a validated stability-indicating high-performance liquid chromatography method. At each sampling time, the suspensions were checked for changes in appearance (i.e., colour, layering, caking, ease of resuspension), odour, and pH. The diclofenac sodium suspensions were very stable, retaining at least 99.5% of the original concentration for up to 93 days, regardless of storage temperature. There were no apparent changes in the physical appearance of the suspensions, nor were there any substantial changes in odour or pH. Suspensions of diclofenac sodium (10 mg/mL) were quantitatively stable but difficult to prepare because of the enteric coating of the tablets. Therefore, it is recommended that diclofenac powder be used for the preparation of suspensions. For pediatric use, palatability is a consideration, and a masking agent should be added before administration. An expiry date of up to

  18. Stability of levothyroxine injection in glass, polyvinyl chloride, and polyolefin containers.

    Science.gov (United States)

    Frenette, Anne Julie; MacLean, Robert D; Williamson, David; Marsolais, Pierre; Donnelly, Ronald F

    2011-09-15

    The 24-hour stability of a levothyroxine solution admixed and stored in three common infusion containers and infused through polyvinyl chloride (PVC) tubing was evaluated. Levothyroxine sodium 1-μg/mL injection prepared in glass bottles and PVC and polyolefin bags were assayed using high-performance liquid chromatography at 0, 1, 3, 6, 12, and 24 hours; samples drawn directly from the containers, as well as from the distal end of attached PVC tubing, were assayed. The area under the time-versus-concentration curve (AUC) for predicted and delivered doses was calculated; analysis of variance was used for comparison of the percentages of predicted and actual AUC values. The levothyroxine concentration was stable in glass bottles and polyolefin bags through 24 hours (mean ± S.D. percentage of initial concentration remaining, 103.5% ± 2.5% and 100.0% ± 2.9%, respectively). In the PVC infusion bags, the amount of drug decreased to 90% of the initial concentration within 1 hour and then rose and remained within acceptability limits. The levothyroxine concentration of the samples infused through PVC line from glass and polyolefin containers decreased after 1 hour by about 13%; the loss of the drug from the samples infused from PVC bags was higher (18%), presumably due to additive adsorptive effects. In all samples tested, the drug concentration rebounded and remained above 90% to the end of the study. Levothyroxine sodium 1-μg/mL solution was stable for 24 hours in glass bottles and polyolefin bags but when stored in PVC bags, the concentration decreased by 10% after 1 hour.

  19. Electrodialytic Transport Properties of Anion-Exchange Membranes Prepared from Poly(vinyl alcohol) and Poly(vinyl alcohol-co-methacryloyl aminopropyl trimethyl ammonium chloride).

    Science.gov (United States)

    Jikihara, Atsushi; Ohashi, Reina; Kakihana, Yuriko; Higa, Mitsuru; Kobayashi, Kenichi

    2013-01-02

    Random-type anion-exchange membranes (AEMs) have been prepared by blending poly(vinyl alcohol) (PVA) and the random copolymer-type polycation, poly(vinyl alcohol-co-methacryloyl aminopropyl trimethyl ammonium chloride) at various molar percentages of anion-exchange groups to vinyl alcohol groups, Cpc, and by cross-linking the PVA chains with glutaraldehyde (GA) solution at various GA concentrations, CGA. The characteristics of the random-type AEMs were compared with blend-type AEMs prepared in our previous study. At equal molar percentages of the anion exchange groups, the water content of the random-type AEMs was lower than that of the blend-type AEMs. The effective charge density of the random-type AEMs increased with increasing Cpc and reached a maximum value. Further, the maximum value of the effective charge density increased with increasing CGA. The maximum value of the effective charge density, 0.42 mol/dm3, was obtained for the random-type AEM with Cpc = 4.2 mol % and CGA = 0.15 vol %. A comparison of the random-type and blend-type AEMs with almost the same Cpc showed that the random-type AEMs had lower membrane resistance than the blend-type ones. The membrane resistance and dynamic transport number of the random-type AEM with Cpc = 6.0 mol % and CGA = 0.15 vol % were 4.8 Ω cm2 and 0.83, respectively.

  20. Extended Stability of Epinephrine Hydrochloride Injection in Polyvinyl Chloride Bags Stored in Amber Ultraviolet Light-Blocking Bags.

    Science.gov (United States)

    Van Matre, Edward T; Ho, Kang C; Lyda, Clark; Fullmer, Beth A; Oldland, Alan R; Kiser, Tyree H

    2017-09-01

    Objective: The objective of this study was to evaluate the stability of epinephrine hydrochloride in 0.9% sodium chloride in polyvinyl chloride bags for up to 60 days. Methods: Dilutions of epinephrine hydrochloride to concentrations of 16 and 64 µg/mL were performed under aseptic conditions. The bags were then placed into ultraviolet light-blocking bags and stored at room temperature (23°C-25°C) or under refrigeration (3°C-5°C). Three samples of each preparation and storage environment were analyzed on days 0, 30, 45, and 60. Physical stability was performed by visual examination. The pH was assessed at baseline and upon final degradation evaluation. Sterility of the samples was not assessed. Chemical stability of epinephrine hydrochloride was evaluated using high-performance liquid chromatography. To determine the stability-indicating nature of the assay, degradation 12 months following preparation was evaluated. Samples were considered stable if there was less than 10% degradation of the initial concentration. Results: Epinephrine hydrochloride diluted to 16 and 64 µg/mL with 0.9% sodium chloride injection and stored in amber ultraviolet light-blocking bags was physically stable throughout the study. No precipitation was observed. At days 30 and 45, all bags had less than 10% degradation. At day 60, all refrigerated bags had less than 10% degradation. Overall, the mean concentration of all measurements demonstrated less than 10% degradation at 60 days at room temperature and under refrigeration. Conclusion: Epinephrine hydrochloride diluted to 16 and 64 µg/mL with 0.9% sodium chloride injection in polyvinyl chloride bags stored in amber ultraviolet light-blocking bags was stable up to 45 days at room temperature and up to 60 days under refrigeration.

  1. Electrical and mechanical investigations on polyvinyl chloride filled with haf black

    International Nuclear Information System (INIS)

    El- Nashar, D.E.; Eid, M.A.M.; Abou Aiad, T.H.; Abd-El-Messieh, S.L.

    2005-01-01

    Polyvinyl chloride (PVC) was chosen to be loaded with various amount of high abrasion furnace black (HAF). The mechanical as well as electrical properties of the prepared composites were investigated. The Dielectric properties of these composites were investigated in the frequency range 10 2 - 10 5 Hz at temperature range from 30 to 120 degree C . In addition to the conductivity term, the experimental data of the dielectric losses ε were analyzed using a computer program based on both Havriliak-Nagami and Frohlich equations into two relaxation processes. The first relaxation process in the lower frequency range could be attributed to Maxwell Wagner effect. The second relaxation could be attributed to the combination of the large scale mobilization of the chains i.e. the glass rubber relaxation process in addition to a contribution of the motion of the large aggregates caused by the movement of the main chain, which are expected to be formed by the addition of different ingredients to PVC such as plasticizer. The percolation threshold concentration, which is the concentration after which the conductivity increases many orders of magnitude with very little increase in the filler amount for PVC/HAF composites depends upon the measuring temperature, whether it is below or above the glass transition of the polymer matrix. Stress strain plot, hardness, and other mechanical properties such as stress at yield, stress at rupture, strain at yield, strain at rupture and Young's Modulus were investigated at room temperature. This investigation led to the conclusion that all the mechanical properties are improved by increasing HAF content and reaches its optimum values at about 30 p hr HAF loading. On the other hand. The addition of HAF black by concentration up to 40 p hr increase the electrical conductivity to be in the order of 10 -10 Sm -1 at 30 degree C and 10 -9 Sm -1 at 120 degree C which highly recommend such composites to be used in anti static applications as the

  2. Polyvinyl chloride as a multimodal tissue-mimicking material with tuned mechanical and medical imaging properties.

    Science.gov (United States)

    Li, Weisi; Belmont, Barry; Greve, Joan M; Manders, Adam B; Downey, Brian C; Zhang, Xi; Xu, Zhen; Guo, Dongming; Shih, Albert

    2016-10-01

    The mechanical and imaging properties of polyvinyl chloride (PVC) can be adjusted to meet the needs of researchers as a tissue-mimicking material. For instance, the hardness can be adjusted by changing the ratio of softener to PVC polymer, mineral oil can be added for lubrication in needle insertion, and glass beads can be added to scatter acoustic energy similar to biological tissue. Through this research, the authors sought to develop a regression model to design formulations of PVC with targeted mechanical and multimodal medical imaging properties. The design of experiment was conducted by varying three factors-(1) the ratio of softener to PVC polymer, (2) the mass fraction of mineral oil, and (3) the mass fraction of glass beads-and measuring the mechanical properties (elastic modulus, hardness, viscoelastic relaxation time constant, and needle insertion friction force) and the medical imaging properties [speed of sound, acoustic attenuation coefficient, magnetic resonance imaging time constants T 1 and T 2 , and the transmittance of the visible light at wavelengths of 695 nm (T λ695 ) and 532 nm (T λ532 )] on twelve soft PVC samples. A regression model was built to describe the relationship between the mechanical and medical imaging properties and the values of the three composition factors of PVC. The model was validated by testing the properties of a PVC sample with a formulation distinct from the twelve samples. The tested soft PVC had elastic moduli from 6 to 45 kPa, hardnesses from 5 to 50 Shore OOO-S, viscoelastic stress relaxation time constants from 114.1 to 191.9 s, friction forces of 18 gauge needle insertion from 0.005 to 0.086 N/mm, speeds of sound from 1393 to 1407 m/s, acoustic attenuation coefficients from 0.38 to 0.61 (dB/cm)/MHz, T 1 relaxation times from 426.3 to 450.2 ms, T 2 relaxation times from 21.5 to 28.4 ms, T λ695 from 46.8% to 92.6%, and T λ532 from 41.1% to 86.3%. Statistically significant factors of each property were

  3. Chloride ion addition for controlling shapes and properties of silver nanorods capped by polyvinyl alcohol synthesized using polyol method

    Energy Technology Data Exchange (ETDEWEB)

    Junaidi, E-mail: junaidi.1982@fmipa.unila.ac.id [Department of Physics, Universitas Gadjah Mada, Yogyakarta, 55281 (Indonesia); Department of Physics, Lampung University, Bandar Lampung (Indonesia); Yunus, Muhammad, E-mail: muhammad.yunus@mail.ugm.ac.id [Department of Physics, Universitas Gadjah Mada, Yogyakarta, 55281 (Indonesia); Triyana, Kuwat, E-mail: triyana@ugm.ac.id; Harsojo,, E-mail: harsojougm@ugm.ac.id; Suharyadi, Edi, E-mail: esuharyadi@ugm.ac.id [Department of Physics, Universitas Gadjah Mada, Yogyakarta, 55281 (Indonesia); Nanomaterials Research Group, Universitas Gadjah Mada, Yogyakarta, 55281 (Indonesia)

    2016-04-19

    We report our investigation on the effect of chloride ions on controlling the shapes and properties of silver nanorods (AgNRs) synthesized using a polyol method. In this study, we used polyvinyl alcohol (PVA) as a capping agent and sodium chloride (NaCl) as a salt precursor and performed at the oil bath temperature of 140°C. The chloride ions originating from the NaCl serve to control the growth of the silver nanorods. Furthermore, the synthesized silver nanorods were characterized using SEM and XRD. The results showed that besides being able to control the growth of AgCl atoms, the chloride ions were also able to control the growth of multi-twinned-particles into the single crystalline of silver nanorods by micrometer-length. At an appropriate concentration of NaCl, the diameter of silver nanorods decreased significantly compared to that of without chloride ion addition. This technique may be useful since a particular diameter of silver nanorods affects a particular application in the future.

  4. Chloride ion addition for controlling shapes and properties of silver nanorods capped by polyvinyl alcohol synthesized by polyol method

    International Nuclear Information System (INIS)

    Junaidi; Triyana, Kuwat; Harsojo,; Suharyadi, Edi

    2016-01-01

    We report our investigation on the effect of chloride ions oncontrolling the shapes and properties of silver nanorods(AgNRs) synthesized using a polyol method. In this study, we used polyvinyl alcohol (PVA) as a capping agent and sodium chloride (NaCl) as asalt precursor and performed at the oilbath temperature of 140 °C. The chloride ions originating from the NaCl serve to control the growth of the silver nanorods. Furthermore, the synthesized silver nanorodswere characterized using UV-VIS, XRD, SEM and TEM. The results showed that besides being able to control the growth of AgCl atoms, the chloride ions were also able to control the growth of multi-twinned-particles into the single crystalline silver nanorods by micrometer-length. At an appropriate concentration of NaCl, the diameter of silver nanorodsdecreased significantly compared to that of without chloride ion addition. This technique may be useful since a particular diameter of silver nanorods affects a particular application in the future.

  5. Chloride ion addition for controlling shapes and properties of silver nanorods capped by polyvinyl alcohol synthesized using polyol method

    International Nuclear Information System (INIS)

    Junaidi; Yunus, Muhammad; Triyana, Kuwat; Harsojo,; Suharyadi, Edi

    2016-01-01

    We report our investigation on the effect of chloride ions on controlling the shapes and properties of silver nanorods (AgNRs) synthesized using a polyol method. In this study, we used polyvinyl alcohol (PVA) as a capping agent and sodium chloride (NaCl) as a salt precursor and performed at the oil bath temperature of 140°C. The chloride ions originating from the NaCl serve to control the growth of the silver nanorods. Furthermore, the synthesized silver nanorods were characterized using SEM and XRD. The results showed that besides being able to control the growth of AgCl atoms, the chloride ions were also able to control the growth of multi-twinned-particles into the single crystalline of silver nanorods by micrometer-length. At an appropriate concentration of NaCl, the diameter of silver nanorods decreased significantly compared to that of without chloride ion addition. This technique may be useful since a particular diameter of silver nanorods affects a particular application in the future.

  6. Polyvinyl Chloride / Attapulgite / Micro-crystalline Cellulose (MCC Composites Preparation and Analysis of the Role of MCC as a Compatibilizer

    Directory of Open Access Journals (Sweden)

    Bo Wang

    2015-09-01

    Full Text Available To improve the performance of polyvinyl chloride (PVC, composites incorporating polyvinyl chloride (PVC, attapulgite nanoparticles (ANPs, and microcrystalline cellulose (MCC were successfully prepared. The composites had higher vicat softening temperatures (VSTs and the MCC had a great influence on mechanical properties of the composites. When MCC was added from 0 to 5 per hundred parts of PVC (phr, the mechanical properties of the composites increased, but the mechanical properties of the composites decreased when the MCC was more than 5 phr. The tensile breaking stress, tensile strength, and impact strength were maximized with increases of 19.76 N (4.1%, 29.66 MPa (15.5%, and 13.8 MPa (7% when 5 phr MCC was added. Infrared spectral analysis indicated that MCC and ANPs were present in the composites. Scanning electron microscopy showed that the composites system was distributed into two phases, which indicated that MCC in composites was dissolved in the PVC matrix, and some of MCC coated the surface of ANPs as a compatibilizer. Overall, this study provided a promising method for PVC modification to improve its performance.

  7. 77 FR 22847 - National Emission Standards for Hazardous Air Pollutants for Polyvinyl Chloride and Copolymers...

    Science.gov (United States)

    2012-04-17

    ... abbreviations are used in this document. CAA Clean Air Act CDD/CDF chlorinated dibenzo-dioxins and furans CDX... chloride and chlorinated dibenzo-dioxins and furans (CDD/CDF)) and hydrogen chloride (HCl). We did not... chloride leak action level because if either of these pollutants is detected in the cooling water or in the...

  8. Synthesis and application of a novel environmental C26 diglycidyl ester plasticizer based on castor oil for poly(vinyl chloride)

    Science.gov (United States)

    In this work, for the first time, a castor oil derived diglycidyl ester plasticizer (C26-DGE) was prepared and incorporated into poly(vinyl chloride) (PVC). The chemical structure of the product was characterized by Fourier transform infrared spectroscopy (FT-IR), proton nuclear magnetic resonance (...

  9. Comparative scanning electron microscope study of the degradation of a plasticized polyvinyl chloride waterproofing membrane in different conditions

    International Nuclear Information System (INIS)

    Pedrosa, A.; Del Río, M.

    2017-01-01

    This paper discusses the analysis of several samples of a plasticized polyvinyl chloride (PVC-P) waterproofing membrane. The samples were extracted from different areas of the same flat roof, which was in service for over 12 years. An original sample of an identical PVC-P membrane that was not installed on the roof was also analyzed. The analysis of the materials was carried out using a scanning electron microscope (SEM). An elemental analysis of every sample was also performed by energy dispersive X-ray spectroscopy (EDS). Micrographs and the elemental composition of the samples were compared with the data obtained in the analysis of the original sample. The results show dehydrochlorination of the polymer in two of the samples studied and great deterioration that was not visible to the naked eye in the sample that was totally exposed to the weather. [es

  10. Thermal degradation and plasticizing mechanism of poly(vinyl chloride) plasticized with a novel cardanol derived plasticizer

    Science.gov (United States)

    Chen, J.; Nie, X. A.; Jiang, J. C.; Zhou, Y. H.

    2018-01-01

    A natural plasticizer cardanol derivatives glycidyl ether (CGE) was synthesized and employed as a plasticizer for the poly(vinyl chloride). The effect of CGE on thermal degradation of PVC films and its plasticizing mechanism were firstly reported. The molecular structure of CGE was characterized with Fourier transform infrared spectroscopy (FTIR). Thermal properties, degradation properties and compatibility of the PVC films were investigated by Differential scanning calorimeter analysis (DSC), Thermogravimetric analysis (TGA) and FTIR, respectively. Compared with the commercial plasticizers dioctylphthalate (DOP), CGE can endow PVC film with a decrease of 4.31 °C in glass transition temperature (Tg), an increase of 24.01 °C and 25.53 °C in 10% weight loss (T 10) and 50% weight loss (T 50) respectively, and a higher activetion energy of thermal degradation (Ea ).

  11. Assessment of control strategies for reducing volatile organic compound emissions from the polyvinyl chloride wallpaper production industry in Taiwan.

    Science.gov (United States)

    Chang, Chang-Tang; Chiou, Chyow-Shan

    2006-05-01

    This study attempts to assess the effectiveness of control strategies for reducing volatile organic compound (VOC) emission from the polyvinyl chloride (PVC) wallpaper production industry. In Taiwan, methyl ethyl ketone, TOL, and cyclohexanone have comprised the major content of solvents, accounting for approximately 113,000 t/yr to avoid excessive viscosity of plasticizer dioctyl phthalate (DOP) and to increase facility in working. Emissions of these VOCs from solvents have caused serious odor and worse air quality problems. In this study, 80 stacks in five factories were tested to evaluate emission characteristics at each VOC source. After examining the VOC concentrations in the flue gases and contents, the VOC emission rate before treatment and from fugitive sources was 93,000 and 800 t/yr, respectively. In this study, the semiwet electrostatic precipitator is recommended for use as cost-effective control equipment.

  12. Active film of poly(vinyl chloride)/silver: synthesis, characterization and evaluation as antimicrobial active packaging

    International Nuclear Information System (INIS)

    Braga, Lilian R.; Rangel, Ellen T.; Machado, Fabricio

    2015-01-01

    The antimicrobial films based on poly(vinyl chloride) (PVC) mediated silver (1, 2, 4 and 8 wt%) were evaluated as antimicrobial active packaging using the casting method. The structure of the active films was characterized by SEM, EDX-XRF, XRD, FTIR and TG. FTIR spectra confirmed the PVC-Ag interaction due to the presence of new bands at 1745 cm"-"1 and 1165 cm"-"1 bands, which are absent in the PVC control. The FRX-EDX spectrum confirmed the presence of silver ions in all the films. TG and SEM results showed that the increased concentration of silver provided an improved thermal stability and presence of pores in the active films, respectively. Antimicrobial activity was evaluated by disk diffusion method for Bacillus subtilis, Fusarium solani and Apergillus niger, which proved the efficiency of the films active. (author)

  13. Stability of penicillin G sodium diluted with 0.9% sodium chloride injection or 5% dextrose injection and stored in polyvinyl chloride bag containers and elastomeric pump containers.

    Science.gov (United States)

    Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire

    2014-04-15

    The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.

  14. Water vapor permeation and dehumidification performance of poly(vinyl alcohol)/lithium chloride composite membranes

    KAUST Repository

    Bui, Duc Thuan; Nida, Aqdas; Ng, Kim  Choon; Chua, Kian  Jon

    2015-01-01

    were observed for membranes with increased lithium chloride content up to 50%. The permeation and sorption properties of the membranes were investigated under different temperatures. The results provided a deeper insight into the membrane water vapor

  15. Recovery of indium from In2O3 and liquid crystal display powder via a chloride volatilization process using polyvinyl chloride

    International Nuclear Information System (INIS)

    Park, Kye-Sung; Sato, Wakao; Grause, Guido; Kameda, Tomohito; Yoshioka, Toshiaki

    2009-01-01

    Indium (In) was recovered from indium oxide (In 2 O 3 ) and liquid crystal display (LCD) powder via a chloride volatilization process using polyvinyl chloride (PVC) as the chlorination agent. The recovery of In from In 2 O 3 increased with an increasing molar Cl/In ratio in N 2 and air atmospheres. The degree of In recovery at a Cl/In molar ratio of 11 and a temperature of 350 o C was 98.7% and 96.6%, for N 2 and air, respectively. The In recovery also increased notably with increasing temperature in N 2 atmosphere. In both atmospheres, the In recovery increased with an increasing degradation temperature of PVC. However, the In recovery from LCD powder was lower than that from In 2 O 3 . For LCD powder, the degree of In recovery at a Cl/In molar ratio of 11 and a temperature of 350 o C was 66.7% and 54.1%, for N 2 and air, respectively.

  16. Fabrication and characterization of a novel hydrophobic CaCO{sub 3} grafted by hydroxylated poly(vinyl chloride) chains

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Lixia [State Key Laboratory of Polymer Materials Engineering, Sichuan University (China); School of Chemical Science and Technology, Yunnan University (China); Yang, Simei; Luo, Xin [School of Chemical Science and Technology, Yunnan University (China); Lei, Jingxin [State Key Laboratory of Polymer Materials Engineering, Sichuan University (China); Cao, Qiue [School of Chemical Science and Technology, Yunnan University (China); Wang, Jiliang, E-mail: jlwang@ynu.edu.cn [School of Chemical Science and Technology, Yunnan University (China)

    2015-12-01

    Highlights: • Hydroxylated poly(vinyl chloride) (PVC-OH) with different molecular weight and hydroxyl value was successfully prepared by the suspension copolymerization. • PVC-OH was grafted onto the surface of CaCO{sub 3} particles by the urethane formation reaction. • The modified CaCO{sub 3} particles show excellent hydrophobicity. - Abstract: The hydroxylated PVC (PVC-OH) was successfully synthesized by a suspension polymerization of vinyl chloride (VC), butyl acrylate (BA) and hydroxyethyl acrylate (HEA). Novel hydrophobic CaCO{sub 3} was then prepared by a urethane formation reaction between methylene diphenyl diisocyanate (MDI) and the −OH groups both in the PVC-OH chains and on the surface of pristine CaCO{sub 3} particles. The effect of the PVC-OH content on the grafting ratio of treated CaCO{sub 3} particles was extensively investigated. Combining the result of Fourier transform infrared (FTIR) with that of water contact angle, it can be concluded that the hydrophobicity of CaCO{sub 3} had been efficiently improved by the PVC-OH segments grafted on the surface of CaCO{sub 3} particles. X-ray diffraction (XRD), thermal gravity analysis (TGA), scanning electron microscope (SEM) and transmission electron microscope (TEM) were also used to study crystalline behaviors, thermal stability and surface morphology of the modified CaCO{sub 3} particles, respectively. The change of specific surface area implying surface modification was investigated as well.

  17. Poly(vinyl chloride) catheters modified with pH-responsive poly(methacrylic acid) with affinity for antimicrobial agents

    Science.gov (United States)

    Zuñiga-Zamorano, Ivette; Meléndez-Ortiz, H. Iván; Costoya, Alejandro; Alvarez-Lorenzo, Carmen; Concheiro, Angel; Bucio, Emilio

    2018-01-01

    Radiation-grafting of pH-responsive methacrylic acid (MAA) onto poly(vinyl chloride) (PVC) was carried out by the pre-irradiation method using gamma rays, which demonstrated to be an efficient and fast procedure for obtaining PVC-g-MAA copolymers. The influence of preparation conditions, such as absorbed dose, monomer concentration, reaction time, and reaction temperature on the grafting yield was studied. The grafting of MAA onto PVC catheters was confirmed by means of Fourier transform infrared spectroscopy (FT-IR), thermogravimetry analysis (TGA), and differential scanning calorimetry (DSC). The pH-responsiveness of the grafted copolymers (critical point 8.5) was measured by swelling under cyclic changes in the pH of the medium. Interestingly, PVC-g-MAA showed enhanced capability to immobilize benzalkonium chloride and, particularly, ciprofloxacin and to sustain the release this antimicrobial agent at both acid and alkaline pH. Tests carried out with Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus point out that the developed functionalized catheters may play a role in the prevention/management of urinary tract infections.

  18. Photostabilizing Efficiency of Poly(vinyl chloride in the Presence of Organotin(IV Complexes as Photostabilizers

    Directory of Open Access Journals (Sweden)

    Mustafa M. Ali

    2016-08-01

    Full Text Available Three organotin complexes containing furosemide as a ligand (L, Ph3SnL, Me2SnL2 and Bu2SnL2, were synthesized and characterized. Octahedral geometry was proposed for the Me2SnL2 and Bu2SnL2, while the Ph3SnL complex has trigonal bipyramid geometry. The synthesized organotin complexes (0.5% by weight were used as additives to improve the photostability of poly(vinyl chloride, PVC, (40 μm thickness upon irradiation. The changes imposed on functional groups, weight loss and viscosity average molecular weight of PVC films were monitored. The experimental results show that the rate of photodegradation was reduced in the presence of the organotin additives. The quantum yield of the chain scission was found to be low (9.8 × 10−7 when Ph3SnL was used as a PVC photostabilizer compared to controlled PVC (5.18 × 10−6. In addition, the atomic force microscope images for the PVC films containing Ph3SnL2 after irradiation shows a smooth surface compared to the controlled films. The rate of PVC photostabilization was found to be highest for Ph3SnL followed by Bu2SnL2 and Me2SnL2. It has been suggested that the organotin complexes could act as hydrogen chloride scavengers, ultraviolet absorbers, peroxide decomposers and/or radical scavengers.

  19. Investigation on pretreatment of centrifugal mother liquid produced in the production of polyvinyl chloride by air-Fenton technique.

    Science.gov (United States)

    Sun, Yingying; Hua, Xiuyi; Ge, Rui; Guo, Aitong; Guo, Zhiyong; Dong, Deming; Sun, Wentian

    2013-08-01

    Centrifugal mother liquid (CML) is one of the main sources of wastewater produced during the production of polyvinyl chloride in chlor-alkali industry. CML is a typical poorly biodegradable organic wastewater, containing many kinds of refractory pollutants. Specifically, it contains dissolved refractory polymers, especially polyvinyl alcohol (PVA), which can pass though the biotreatment processes and clog the membranes used for further treatment. In this study, to ensure the CML applicable to biotreatment and membrane treatment, a novel efficient and mild technique, air-Fenton treatment, was employed as a pretreatment technique to improve biodegradability of the CML and to break down the polymers in the CML. Firstly, the technique was optimized for the CML treatment by optimizing the main parameters, including the dosage of ferrous sulfate, initial pH of the wastewater, [H2O2]/[Fe(2+)], aeration rate, reaction time, and temperature, based on removal efficiency of COD and PVA from the CML. Then, the optimized technique was tested and evaluated. The results indicated that under the optimized conditions, the air-Fenton treatment could remove 66, 98, and 55 % of the COD, PVA, and TOC, respectively, from the CML. After the treatment, biodegradability of the wastewater increased significantly (BOD/COD increased from 0.31 to 0.68), and almost all of the PVA polymers were removed or broken down. Meanwhile, concentration of the remaining iron ions, which were added during the treatment, was also quite low (only 2.9 mg/L). Furthermore, most of the suspended materials and ammonia nitrogen, and some of the phosphorus in the wastewater were removed simultaneously.

  20. Uranium Adsorbent Fibers Prepared by Atom-Transfer Radical Polymerization (ATRP) from Poly(vinyl chloride)- co -chlorinated Poly(vinyl chloride) (PVC- co -CPVC) Fiber

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Suree; Yue, Yanfeng; Kuo, Li-Jung; Mehio, Nada; Li, Meijun; Gill, Gary; Tsouris, Costas; Mayes, Richard T.; Saito, Tomonori; Dai, Sheng

    2016-04-20

    The need to secure future supplies of energy attracts researchers in several countries to a vast resource of nuclear energy fuel: uranium in seawater (estimated at 4.5 billion tons in seawater). In this study, we developed effective adsorbent fibers for the recovery of uranium from seawater via atom-transfer radical polymerization (ATRP) from a poly- (vinyl chloride)-co-chlorinated poly(vinyl chloride) (PVC-co-CPVC) fiber. ATRP was employed in the surface graft polymerization of acrylonitrile (AN) and tert-butyl acrylate (tBA), precursors for uranium-interacting functional groups, from PVC-co-CPVC fiber. The [tBA]/[AN] was systematically varied to identify the optimal ratio between hydrophilic groups (from tBA) and uranyl-binding ligands (from AN). The best performing adsorbent fiber, the one with the optimal [tBA]/[AN] ratio and a high degree of grafting (1390%), demonstrated uranium adsorption capacities that are significantly greater than those of the Japan Atomic Energy Agency (JAEA) reference fiber in natural seawater tests (2.42-3.24 g/kg in 42 days of seawater exposure and 5.22 g/kg in 49 days of seawater exposure, versus 1.66 g/kg in 42 days of seawater exposure and 1.71 g/kg in 49 days of seawater exposure for JAEA). Adsorption of other metal ions from seawater and their corresponding kinetics were also studied. The grafting of alternative monomers for the recovery of uranium from seawater is now under development by this versatile technique of ATRP.

  1. ANALYSIS OF ADIPATE ESTER CONTENTS IN POLY(VINYL CHLORIDE) PLASTICS

    DEFF Research Database (Denmark)

    Berg, Rolf W.; Otero, Amalia Dopazo

    2006-01-01

    Fourier transform (FT-) Raman spectroscopy excited with a 1064 nm laser can be used to determine the content of plasticizers in commercial flexible poly vinyl chloride (PVC) products. Our previous study [T. Nørbygaard, R.W. Berg, Analysis of phthalate ester content in PVC plastics by means of FT......-Raman Spectroscopy, Appl. Spectrosc. 58 (4) (2004) 410–413]—on detection of the presence of phthalate esters in PVC by FT-Raman spectroscopy — is here extended to the similar case of adipate esters (AEs) in samples of soft poly vinyl chloride plastics. Spectra of a range of adipate ester plasticizers (11 AEs......) in pure form are reported. We studied if qualitative and quantitative determination of the adipate ester content would be possible based on the use of proper reference samples. It was found that AEs as a group cannot be definitively identified by their characteristic Raman bands because other aliphatic...

  2. Influence of potassium fluoride on the syntheses of methylpiperazine-modified poly(vinyl chloride)s for use as fixed-site proton carrier membranes.

    Science.gov (United States)

    Roudman, A R; Kusy, R P

    1998-03-15

    Aminated poly(vinyl chloride) (PVC) membranes were prepared that had a Nernstian response over a wide range of pH. The reaction between PVC and methyl-piperazine (MePIP) in dimethylformamide (DMF) was studied over a wide range of time and temperature, and in the presence of the catalyst, potassium fluoride (KF). Time, temperature, and KF increased the nitrogen (N) content of the resulting polymers, but sometimes at the expense of decreasing their specific viscosities (molecular weights). Activation energies of processes that occurred in different temperature ranges were estimated assuming an Arrhenius relationship. A Nernstian response occurred once the N content approached to about 0.3 w/w %, and was accelerated by the presence of KF at elevated temperatures. Increasing the N content above about 3% led to a loss of the Nernstian response either because of an increase in the double bond content and a subsequent decrease in polymer mobility, or because of a decrease in the molecular weight of the copolymer and concomitant difficulties in film preparation.

  3. Mechanical and interfacial properties of poly(vinyl chloride) based composites reinforced by cassava stillage residue with different surface treatments

    Science.gov (United States)

    Zhang, Yanjuan; Gan, Tao; Li, Qian; Su, Jianmei; Lin, Ye; Wei, Yongzuo; Huang, Zuqiang; Yang, Mei

    2014-09-01

    Cassava stillage residue (CSR), a kind of agro-industrial plant fiber, was modified by coupling agent (CA), mechanical activation (MA), and MA-assisted CA (MACA) surface treatments, respectively. The untreated and different surface treated CSRs were used to prepare plant fibers/polymer composites (PFPC) with poly(vinyl chloride) (PVC) as polymer matrix, and the properties of these CSR/PVC composites were compared. Surface treated CSR/PVC composites possessed better mechanical properties, water resistance and dimensional stability compared with the untreated CSR/PVC composite, attributing to the improvement of interfacial properties between CSR and PVC matrix. MACA-treated CSR was the best reinforcement among four types of CSRs (untreated, MA-treated, CA-treated, and MACA-treated CSRs) because MACA treatment led to the significant improvement of dispersion, interfacial adhesion and compatibility between CSR and PVC. MACA treatment could be considered as an effective and green method for enhancing reinforcement efficiency of plant fibers and the properties of PFPC.

  4. Enhancement of the thermal and mechanical properties of polyurethane/polyvinyl chloride blend by loading single walled carbon nanotubes

    Directory of Open Access Journals (Sweden)

    A.M. Hezma

    2017-06-01

    Full Text Available Structural, thermal, and mechanical properties of pure blend and nanocomposites based on polyurethane (PU and polyvinyl chloride (PVC doped with low different content of single walled-carbon nanotubes (SWCNTs were studied. The nanocomposites at different concentration were prepared via casting technique. The interaction between PU/PVC and CNTs were examined via FT-IR studies. The changes in the structures of the nanocomposites were examined using X- Ray Diffraction (XRD, and the results indicated that the amorphous domains of nanocomposites increased with increasing SWCNTs content. Transmission electron microscope (TEM observation indicated that SWCNTs surface was wrapped with the polymer with the thermal properties of nanocomposites improved. The mechanical behavior of the nanocomposites was evaluated as a function of SWCNTs content. The main enhancement in tensile properties was observed, e.g., the tensile strength and elastic modulus increased compared with the pure blend, which may be attributed to the interaction and adhesion between CNTs and the polymer matrices due to the hydrogen bonding between carbonyl groups (C=O of polymer blend chains and carboxylic acid (COOH groups of CNTs.

  5. Protein valves prepared by click reaction grafting of poly(N-isopropylacrylamide) to electrospun poly(vinyl chloride) fibrous membranes

    Science.gov (United States)

    Guo, Jian-Wei; Lin, Zhen-Yu; Chang, Chi-Jung; Lu, Chien-Hsing; Chen, Jem-Kun

    2018-05-01

    In this study, poly(vinyl chloride) (PVC) was electrospun into fibrous membranes and then reacted with NaN3 to generate azido-terminated PVC fibrous membranes. A propargyl-terminated poly(N-isopropylacrylamide) (PNIPAAm) was also synthesized and then grafted, through click reactions, onto the azido-terminated PVC fiber surface. Protrusion-, scale-, and joint-like structures of the PNIPAAm grafts on the PVC fibers were formed upon increasing the molecular weight of the PNIPAAm grafts. The PNIPAAm-grafted PVC fibrous mats exhibited completely wetted surfaces at 25 °C because of their high roughness. The static water contact angle of the PNIPAAm-grafted PVC fibrous mats reached 140° when the temperature was increased to 45 °C. This thermoresponsive behavior was significantly greater than that of the PNIPAAm grafted on a flat surface. Temperature-responsive membranes were constructed having a pore size of 1.38 μm and applied as protein valves to block and release an antibody (fluorescein-conjugated AffiniPure goat anti-rabbit IgG). At 25 °C, the collection efficiency remained at 94% for antibody concentrations up to 60 ng/L. As the temperature increased to 45 °C, the collection efficiency decreased abruptly, to 4%, when the antibody concentration was greater than 20 ng/L. Accordingly, this system of PNIPAAm-grafted PVC fibers functioned as a protein valve allowing the capture and concentration of proteins.

  6. [Determination of short chain chlorinated paraffins in polyvinyl chloride plastics by gas chromatography-negative chemical ion/mass spectrometry].

    Science.gov (United States)

    Xing, Yuanna; Lin, Zhihui; Feng, Anhong; Wang, Xin; Gong, Yemeng; Chen, Zeyong

    2015-02-01

    A novel method was established to determine short chain chlorinated paraffins (SC-CPs) in polyvinyl chloride (PVC) plastics by gas chromatography-negative chemical ion/mass spectrometry (GC-NCI/MS). Ultrasonic extraction was used to extract SCCPs from PVC plastics. The optimal extraction time was 1.5 h, and concentrated sulfuric acid was adopted to purify the extracted solution. Finally, SCCPs in a sample were detected by GC-NCI/MS at 160 C and with methane reagent gas at 1. 5 mL/min. This method was not influenced by medium chain chlorinated paraffins (MCCPs) in the sample, and accurate quantitation was made for SCCPs. Twelve batches of samples were analyzed and SCCPs were detected in each batch with the contents from 0. 3 x 10(2)mg/kg to 3. 5 x 10(4)mg/kg. With respect to European limitation of SC-CPs (1%), four batches of samples did not comply with the European regulation, and they accounted for 33. 3%. Obviously, high SCCPs risk was presented in PVC plastics.

  7. Sonochemical synthesis of cooper II sulfide nanoparticles and their use as radiolytic stabilizer in polyvinyl chloride matrix

    International Nuclear Information System (INIS)

    Freitas, Danubia Maria da Silva; Lima, Thaysa Araujo de; Aquino, Katia Aparecida da Silva; Araujo, Elmo S.

    2013-01-01

    Cooper (II) sulfide (CuS) was synthesized by sonochemical method. CuS crystals with hexagonal structure exhibit irregular aggregates of particles with an average size in the range of 250-900 nm. Commercial Polyvinyl chloride (PVC) containing CuS nanoparticles (PVC/CuS) at concentrations of 0.10; 0.30; 0.50 and 0.70 wt% were investigated. The samples were irradiated with gamma radiation ( 60 Co) at room temperature and air atmosphere. The viscosity-average molar mass (M v ) was measured for PVC systems without nanoparticles and with nanoparticles. Decrease in viscosity molar mass was observed when the systems were gamma irradiated reflect the random scission effects that take place in the main chain. Degradation index (DI) value was also obtained by viscosity analysis. DI results showed that the addition of CuS nanoparticles at 0.5 wt% into PVC matrix decreased the number of main chain scissions at dose of 25 kGy and was calculated a protection of 84% in PVC matrix. CuS nanoparticles act as free radical scavenger into gamma-irradiated PVC systems. The interactions between CuS and PVC favor action of nanoparticles as a good plasticizer in the PVC molecule. (author)

  8. Effect of Palm Oil Bio-Based Plasticizer on the Morphological, Thermal and Mechanical Properties of Poly(Vinyl Chloride

    Directory of Open Access Journals (Sweden)

    Kar Min Lim

    2015-10-01

    Full Text Available Flexible poly(vinyl chloride (PVC was fabricated using a palm oil-based alkyd as a co-plasticizer to di-octyl phthalate (DOP and di-isononyl phthalate (DiNP. The effects of the incorporation of the palm oil-based alkyd on morphological, thermal and mechanical properties of PVC compounds were studied. Results showed the incorporation of the alkyd enhanced the mechanical and thermal properties of the PVC compounds. Fourier transform infrared spectroscopy (FTIR results showed that the polar –OH and –C=O groups of alkyd have good interaction with the –C–Cl group in PVC via polar interaction. The morphological results showed good incorporation of the plasticizers with PVC. Improved tensile strength, elastic modulus, and elongation at break were observed with increasing amount of the alkyd, presumably due to chain entanglement of the alkyd with the PVC molecules. Thermogravimetric analysis results confirmed that the alkyd has improved the thermostability of the PVC compounds.

  9. A novel process for separation of hazardous poly(vinyl chloride) from mixed plastic wastes by froth flotation.

    Science.gov (United States)

    Wang, Jianchao; Wang, Hui; Wang, Chongqing; Zhang, Lingling; Wang, Tao; Zheng, Long

    2017-11-01

    A novel method, calcium hypochlorite (CHC) treatment, was proposed for separation of hazardous poly(vinyl chloride) (PVC) plastic from mixed plastic wastes (MPWs) by froth flotation. Flotation behavior of single plastic indicates that PVC can be separated from poly(ethylene terephthalate) (PET), poly(acrylonitrile-co-butadiene-co-styrene) (ABS), polystyrene (PS), polycarbonate (PC) and poly(methyl methacrylate) (PMMA) by froth flotation combined with CHC treatment. Mechanism of CHC treatment was examined by contact angle measurement, scanning electron microscopy, Fourier transform infrared and X-ray photoelectron spectroscopy. Under the optimum conditions, separation of PVC from binary plastics with different particle sizes is achieved efficiently. The purity of PC, ABS, PMMA, PS and PET is greater than 96.8%, 98.5%, 98.8%, 97.4% and 96.3%, respectively. Separation of PVC from multi-plastics was further conducted by two-stage flotation. PVC can be separated efficiently from MPWs with residue content of 0.37%. Additionally, reusing CHC solution is practical. This work indicates that separation of hazardous PVC from MPWs is effective by froth flotation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Influence of inorganic salts mixture and a commercial additive on the degradation of poly(vinyl chloride)

    International Nuclear Information System (INIS)

    Silva, Williams B. da; Vasconcelos, Henrique M. de; Aquino, Katia Aparecida da S.; Araujo, Elmo S. de

    2009-01-01

    Samples of commercial poly(vinyl chloride) (PVC) containing a Hindered Amine Stabilizer (HAS) and samples containing a salt mixture of CuCl 2 /KI both in 0.1, 0.3, 0.5 and 0.7wt% concentration of HAS or salt mixture were investigated. The samples were irradiated with gamma radiation ( 60 Co) at room temperature in air at 25 kGy, sterilization dose of PVC medical supplies. The viscosity-average molecular weight (Mv) was analyzed by viscosity technique. Comparison of viscosity results obtained before and after irradiation ( at 25 kGy) of PVC showed crosslinking effect is predominant. On the other hand the PVC-HAS systems and PVC-salt systems showed a decrease in Mv values on irradiated samples reflecting the main chain random scissions effect. However the PVC-salt at 0.5wt% concentration showed no significant degradation index value. This result suggests that salt keeps the good radiolytic stabilization behavior of gamma-irradiated PVC and the HAS additive is not efficient on radiolytic stabilization of PVC. The CuCl 2 /KI mixture at 0.5wt% in the PVC matrix influenced the thermal behavior of the polymer increasing of 42 deg C in maximum thermal degradation temperature. In addition, the salt mixture influences significantly the Young's Modulus of PVC increasing the rigidity of polymer. (author)

  11. Consequences of poly(vinyl chloride) presence on the thermochemical process of lignocellulosic biomass in CO₂ by thermogravimetric analysis.

    Science.gov (United States)

    He, Yao; Ma, Xiaoqian; Zeng, Guangbo

    2015-02-01

    The thermochemical processes of lignocellulosic biomass and its mixtures with poly(vinyl chloride) (PVC) fractions were investigated by thermogravimetric analysis in CO2 atmosphere. Superposition property was assumed to examine whether and/or to what extent interactions occurred during the mixture decomposition. Results showed that interactions existed, of which the intensities changed with reaction stage, heating rate and PVC quantity, and they actively behaved toward the decomposition in most cases. With PVC presence, lignocellulosic biomass turned from three-stage to four-stage decomposition process where the reactions occurred at lower temperatures with heightened intensity, especially in the first stage. The measured activation energies calculated by Ozawa-Flynn-Wall and Vyazovkin methods were of minor difference <5 kJ/mol, and comparing them between materials in each stage confirmed the results of interaction impact. This work provides a theoretical basis bringing about the possibilities of recycling CO2 into a reaction medium of thermo-treatment of lignocellulosic material with PVC contaminants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Electron Beam Damage in Poly(Vinyl Chloride) and Poly(Acrylonitrile) as Observed by Auger Electron Spectroscopy

    International Nuclear Information System (INIS)

    Lea, Alan S.; Engelhard, Mark H.; Baer, Donald R.

    2003-01-01

    AES spectra of spun-cast films of poly(vinyl chloride) (PVC) and poly(acrylonitrile) (PAN) were collected over a period of time to determine specimen damage during exposure to a 10kV electron beam. For the PVC, loss of chlorine was observed over a period of 203 minutes to the extent that the final chlorine concentration was only 20% of its original value. PAN exhibited a loss in nitrogen content over a period of 120 minutes, but the rate of damage to the polymer was significantly less than PVC. Figure 1 shows the atomic concentration in the PVC film as a function of dose (time). It takes a dose of approximately 7.0x10-5 Ccm-5 for the chlorine concentration to fall from its original value by 10% (one definition of critical dose). Figure 2 shows a similar drop in nitrogen concentration in the PAN film as a function of dose. For this polymer, it takes a dose of 1.3x10-3 Ccm-2 for the nitrogen concentration to fall by 10%

  13. Effect of irradiation on poly(vinyl chloride)/epoxidized natural rubber blend in the presence of additives: FTIR analysis

    International Nuclear Information System (INIS)

    Chantara Thevy Ratnam; Khairul Zaman Dahlan; Baharin, A.; Nasir, M.

    2001-01-01

    The effect of irradiation on the structure of 50/50 poly(vinyl chloride)/epoxidized natural rubber blend (PVC/ENR) was studied using the Fourier Transform Spectroscopy (FTIR). The 50/50 PVC/ENR blend was irradiated by using 3.0 MeV electron beam machine at 0 and 200 kGy irradiation doses. The influence of several additives such as TMPTA, Irganox 1010, and tribasic lead sulfate on the irradiation induced changes of the blend was investigated. It was found that upon irradiation, ring opening of the epoxide groups, oxidation as well crosslinking at residual double bonds occurred, leading to decreases in the intensities of the epoxide and cis double bond bands and an increases in ether and furan bands. The addition of Irganox 1010 and tribasic lead sulfate were found to inhibit the irradiation-induced reaction in the blend to a considerable extent. The importance of TMPTA in preventing the intramolecular ring opening side chain reaction was also discussed. However, studies did not reveal the exact nature of the irradiation-induced reactions involved in the blend. (Author)

  14. DIELECTRIC AND PYROELECTRIC PROPERTIES OF THE COMPOSITES OF FERROELECTRIC CERAMIC AND POLY(VINYL CHLORIDE

    Directory of Open Access Journals (Sweden)

    M.Olszowy

    2003-01-01

    Full Text Available The dielectric and pyroelectric properties of lead zirconate titanate/poly(vinyl chloride [PZT/PVC] and barium titanate/poly(vinyl chloride [BaTiO3/ PVC] composites were studied. Flexible composites were fabricated in the thin films form (200-400 μm by hot-pressed method. Powders of PZT or BaTiO3 in the shape of ≤ 75 μm ceramics particles were dispersed in a PVC matrix, providing composites with 0-3} connectivity. Distribution of the ceramic particles in the polymer phase was examined by scanning electron microscopy. The analysis of the thermally stimulated currents (TSC have also been done. The changes of dielectric and pyroelectric data on composites with different contents of ceramics up to 40% volume were investigated. The dielectric constants were measured in the frequency range from 600 Hz to 6 MHz at room temperature. The pyroelectric coefficient for BaTiO3/PVC composite at 343 K is about 35 μC/m2K which is higher than that of β-PVDF (10 μC/m2 K.

  15. Pyrolysis of poly(vinyl chloride) and-electric arc furnacedust mixtures.

    Science.gov (United States)

    Al-Harahsheh, Mohammad; Al-Otoom, Awni; Al-Makhadmah, Leema; Hamilton, Ian E; Kingman, Sam; Al-Asheh, Sameer; Hararah, Muhanned

    2015-12-15

    An investigation into the pyrolysis kinetics of PVC mixed with electric arc furnace dust (EAFD) was performed. Mixtures of both materials with varying PVC ratios (1:1, 1:2, 1:3) were prepared and pyrolyzed in a nitrogen atmosphere under dynamic heating conditions at different heating rates (5, 10, 30 and 50 °C/min). The pyrolysis process proceeded through two main decomposition steps; the first step involved the release of HCl which reacted with the metal oxides present in the dust, subsequently forming metal chlorides and water vapor. Benzene was also found to release as detected by TGA-MS. The remaining hydrocarbons in the polymer backbone decomposed further in the second step releasing further volatile hydrocarbons. Different models were used to fit the kinetic data namely the integral, the Van Krevelen, and Coats and Red fern methods. The presence of EAFD during PVC decomposition resulted in a considerable decrease in the activation energy of the reaction occurring during the first decomposition region. Furthermore, iron oxides were retained in the pyrolysis residue, whilst other valuable metals, including Zn and Pb, were converted to chlorides that are recoverable by leaching in water. It is believed that EAFD can be utilized as an active catalyst to produce energy gases such as propyneas evident from the TGA-MS. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Solid-phase extraction of cobalt(II) from lithium chloride solutions using a poly(vinyl chloride)-based polymer inclusion membrane with Aliquat 336 as the carrier.

    Science.gov (United States)

    Kagaya, Shigehiro; Cattrall, Robert W; Kolev, Spas D

    2011-01-01

    The extraction of cobalt(II) from solutions containing various concentrations of lithium chloride, hydrochloric acid, and mixtures of lithium chloride plus hydrochloric acid is reported using a poly(vinyl chloride) (PVC)-based polymer inclusion membrane (PIM) containing 40% (w/w) Aliquat 336 as a carrier. The extraction from lithium chloride solutions and mixtures with hydrochloric acid is shown to be more effective than extraction from hydrochloric acid solutions alone. The solution concentrations giving the highest amounts of extraction are 7 mol L(-1) for lithium chloride and 8 mol L(-1) lithium chloride plus 1 mol L(-1) hydrochloric acid for mixed solutions. Cobalt(II) is easily stripped from the membrane using deionized water. The cobalt(II) species extracted into the membrane are CoCl(4)(2-) for lithium chloride solutions and HCoCl(4)(-) for mixed solutions; these form ion-pairs with Aliquat 336. It is also shown that both lithium chloride and hydrochloric acid are extracted by the PIM and suppress the extraction of cobalt(II) by forming ion-pairs in the membrane (i.e. R(3)MeN(+)·HCl(2)(-) for hydrochloric acid and R(3)MeN(+)·LiCl(2)(-) for lithium chloride). 2011 © The Japan Society for Analytical Chemistry

  17. Stability assessment of lyophilized intravenous immunoglobulin after reconstitution in glass containers and poly(vinyl chloride) bags.

    Science.gov (United States)

    Parti, R; Mankarious, S

    1997-02-01

    Human intravenous immunoglobulin (IGIV) has been in use for the past 20 years. This biological product is commonly provided in liquid or lyophilized dosage form. When the lyophilized product is rehydrated, it is usually administered within 2-3 h from time of complete dissolution. While this practice is advisable whenever possible, occasionally the patient or care-giver may need to delay the infusion. Hence, a study of the stability of lyophilized IGIV after reconstitution with water for injection was conducted. The reconstituted product was stored either in its original glass container or pooled into poly(vinyl chloride) (PVC) bags. The effect of extended storage on the active ingredient (IgG), excipients (glucose, albumin) and extractables [sodium from glass vials, and di-(2-ethyl-hexyl) phthalate and cyclohexanone from PVC bags] was evaluated. The stability of the active ingredient was evaluated by physico-chemical tests (molecularsize distribution, pH, appearance, total protein), monitoring titres of a specific antibody (hepatitis B surface antigen) and an antibody functional test (bacterial opsonization). To evaluate the risk of microbial contamination during reconstitution and pooling procedures, sterility, pyrogen and animal-safety tests were included in the protocol. The potential of IgG polymerizing in solution during storage and subsequent complement activation was evaluated by assaying for non-specific binding of complement (anti-complement activity). Results show that aseptically reconstituted IGIV is stable and remains sterile up to 48 h at 5 degrees C. The reconstituted product was also found to be stable at room temperature (25 degrees C) up to 12 h.

  18. Stability of midazolam hydrochloride injection 1-mg/mL solutions in polyvinyl chloride and polyolefin bags.

    Science.gov (United States)

    Karlage, Kelly; Earhart, Zachary; Green-Boesen, Kelly; Myrdal, Paul B

    2011-08-15

    The stability of midazolam hydrochloride injection 1-mg/mL solutions in polyvinyl chloride (PVC) and polyolefin bags under varying conditions was evaluated. Triplicate solutions of midazolam hydrochloride 1-mg/mL were prepared in polyolefin and PVC i.v. bags by diluting midazolam hydrochloride injection 5 mg/mL with 5% dextrose injection. Bags were then stored under refrigeration (3-4 °C), exposed to light at room temperature (20-25 °C), or protected from light in amber bags at room temperature. Samples were taken immediately after preparation (day 0) and on days 1, 2, 3, 6, 13, 20, and 27 for analysis with a stability-indicating high-performance liquid chromatography assay in order to determine solution concentration. Stability was defined as retention of at least 90% of the initial drug concentration. The pH of each solution was also measured weekly. Sterility of the i.v. bags was determined at the end of the study by microbiological testing with culture in growth media. Differences in concentrations under the various storage conditions and bags used were analyzed using analysis of variance. All solutions retained over 98% of the initial midazolam hydrochloride concentration, with no statistically significant (p ≥ 0.05) change in concentration over the four-week period. Stability was not affected by temperature, exposure to light, or bag type. The pH of all solutions remained between 3.2 and 3.4 throughout the study. Sterility after 28 days was retained. Midazolam hydrochloride 1-mg/mL solutions diluted in 5% dextrose injection remained stable over 27 days in both polyolefin and PVC i.v. bags, regardless of storage condition.

  19. The effect of iatrogenic Staphylococcus epidermidis intercellar adhesion operon on the formation of bacterial biofilm on polyvinyl chloride surfaces.

    Science.gov (United States)

    Lianhua, Ye; Yunchao, Huang; Guangqiang, Zhao; Kun, Yang; Xing, Liu; Fengli, Guo

    2014-12-01

    The intercellular adhesion gene (ica) of Staphylococcus epidermidis is a key factor for bacterial aggregation. This study explored the effect of ica on the formation of bacterial biofilm on polyvinyl chloride (PVC) surfaces. Genes related to bacterial biofilm formation, including 16S rRNA, autolysin (atlE), fibrinogen binding protein gene (fbe), and ica were identified and sequenced from 112 clinical isolates of iatrogenic S. epidermidis by polymerase chain reaction (PCR) and gene sequencing. Based on the sequencing result, ica operon-positive (icaADB+/atlE+/fbe+) and ica operon-negative (icaADB-/atlE+/fbe+) strains were separated and co-cultivated with PVC material. After 6, 12, 18, 24, and 30 h of co-culture, the thickness of the bacterial biofilm and quantity of bacterial colony on the PVC surface were measured under the confocal laser scanning microscope and scanning electron microscope. The positive rate of S. epidermidis-specific 16SrRNA in 112 iatrogenic strains was 100% (112/112). The genotype of ica-positive (icaADB+/atlE+/fbe+) strains accounted for 57.1% (64/112), and genotype of ica-negative (icaADB-/atlE+/fbe+) strains accounted for 37.5% (42/112). During 30 h of co-culture, no obvious bacterial biofilm formed on the surface of PVC in the ica-positive group, however, mature bacterial biofilm structure formed after 24 h. For all time points, thickness of bacterial biofilm and quantity of bacterial colony on PVC surfaces in the ica operon-positive group were significantly higher than those in ica operon-negative group (poperon-negative and ica operon-positive strains. The ica operon plays an important role in bacterial biofilm formation and bacterial multiplication on PVC material.

  20. A novel process for separation of polycarbonate, polyvinyl chloride and polymethyl methacrylate waste plastics by froth flotation.

    Science.gov (United States)

    Wang, Chong-Qing; Wang, Hui; Huang, Luo-Luo

    2017-07-01

    A novel process was proposed for separation of ternary waste plastics by froth flotation. Pretreatment of plastics with potassium permanganate (KMnO 4 ) solution was conducted to aid flotation separation of polycarbonate (PC), polyvinyl chloride (PVC) and polymethyl methacrylate (PMMA) plastics. The effect of pretreatment parameters including KMnO 4 concentration, treatment time, temperature and stirring rate on flotation recovery were investigated by single factor experiments. Surface treatment with KMnO 4 changes selectively the flotation behavior of PC, PVC and PMMA, enabling separation of the plastics by froth flotation. Mechanism of surface treatment was studied by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray photoelectron spectrum (XPS). Effect of frother concentration and flotation time on flotation behavior of plastic mixtures was further studied for flotation separation. The optimized conditions for separation of PC are KMnO 4 concentration 2mmolL -1 , treatment time 10min, temperature 60°C, stirring rate 300rpm, flotation time 1min and frother concentration 17.5mgL -1 . Under optimum conditions, PVC and PMMA mixtures are also separated efficiently by froth flotation associated with KMnO 4 treatment. The purity of PC, PVC and PMMA is up to 100%, 98.41% and 98.68%, while the recovery reaches 96.82%, 98.71% and 98.38%, respectively. Economic analysis manifests remarkable profits of the developed process. Reusing KMnO 4 solution is feasible, enabling the process greener. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Physicochemical stability of oxaliplatin in 5% dextrose injection stored in polyvinyl chloride, polyethylene, and polypropylene infusion bags.

    Science.gov (United States)

    Eiden, Céline; Philibert, Laurent; Bekhtari, Khedidja; Poujol, Sylvain; Malosse, Francoise; Pinguet, Frédéric

    2009-11-01

    The physicochemical stability of extemporaneous dilutions of oxaliplatin in 5% dextrose injection stored in polyvinyl chloride (PVC), polypropylene, and polyethylene infusion bags was studied. Oxaliplatin 100 mg/20 mL concentrated solution was diluted in 100 mL of 5% dextrose injection in PVC, polypropylene, and polyethylene infusion bags to produce nominal oxaliplatin concentrations of 0.2 and 1.3 mg/mL. The filled bags were stored for 14 days at 20 degrees C and protected from light, at 20 degrees C under normal fluorescent light, and at 4 degrees C. A 1-mL sample was removed from each bag at time 0 and at 24, 48, 72, 120, 168, and 336 hours. The samples were visually inspected for color and clarity, and the pH values of the solutions were measured. High-performance liquid chromatography was used to assay oxaliplatin concentration. Bacterial contamination was assessed on study day 14 after incubation in trypticase soy solution for three days at 37 degrees C. Solutions of oxaliplatin 0.2 and 1.3 mg/mL in 5% dextrose injection were stable in the three container types for at least 14 days at both 4 degrees C and 20 degrees C without regard to light exposure. No color change was detected during the storage period, and pH values remained stable. No microbial contamination was detected in any samples over the study period. Oxaliplatin solutions diluted in 5% dextrose injection to 0.2 and 1.3 mg/mL were stable in PVC and PVC-free infusion bags for at least 14 days at both 4 degrees C and 20 degrees C without regard to light exposure.

  2. Lead removal from cathode ray tube glass by the action of calcium hydroxide and poly(vinyl chloride)

    International Nuclear Information System (INIS)

    Grause, Guido; Takahashi, Kenshi; Kameda, Tomohito; Yoshioka, Toshiaki

    2014-01-01

    Highlights: • About 99.9% of lead is removed from CRT glass by PbCl 2 volatilization. • PVC is used as chlorination agent with the aid of Ca(OH) 2 as HCl absorbing material. • The residual calcium silicate has a lead content as low as 140 mg kg −1 . • Lead leaching from the residue was below the detection limit. - Abstract: With the development of flat screen technology, the cathode ray tubes (CRTs) used in TV sets became obsolete, leaving huge amounts of lead-containing CRT glass for disposal. We developed a novel lead volatilization process in which PbCl 2 was generated in the presence of poly(vinyl chloride) (PVC) as a chlorination agent and Ca(OH) 2 as an HCl absorber. PVC was incinerated in air atmosphere and the resulting HCl was captured by Ca(OH) 2 before exiting the reactor with the air flow. CaCl 2 and Ca(OH) 2 reacted with the lead glass forming volatile PbCl 2 and crystalline Ca-silicates. Since the reactivity of lead glass with gaseous HCl is negligible, the presence of Ca(OH) 2 was essential for the success of this method. At a temperature of 1000 °C, a molar Cl/Pb ratio of 16, and a molar Ca/Si ratio of about 2, approximately 99.9% of the lead was volatilized, leaving a residue with a lead content of 140 mg kg −1 . The residual calcium silicate, with its low lead level, has the potential to be repurposed for other uses

  3. Determinations of phase transitions in nylon 6-12, nylon-6, polyvinyl chloride and polyethylene terephthalate by positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Camacho Reyes, M.J.

    1993-01-01

    Positron annihilation lifetime spectroscopy (PALS) was used to investigate the phase transitions, mainly the glass transition, of poly(vinyl chloride) (PVC), Nylon-6,12, Nylon-6, poly(ethylene terephthalate) during the thermal treatment of these polymers. The longest lived component lifetime and intensity, indicative of ortho-Positronium pick-off exhibit thermal dependencies that can be attributed to the anticipated free volume changes associated with structural transitions. Positron lifetime measurements were performed using an E G and G Ortec standard fast-fast coincidence system. Three spectra were collected at each temperature, each consisting of a peak height of approximately 25000 counts. The resulting spectra were consistently modeled with a three component fit using the computer program PATFIT. For nylon-6,12, nylon-6, PVC systems three transitions were obtained in both tau-3 and I-3 as a function of temperature. Changes in the slope of the curves appear for both parameters, these could be attributed to T g1 , T g2 and T c , respectively. In the case of PET analysis two transitions were obtained as is shown by the variations of tau-3 as a function of the heating temperature. These transitions can be attributed to T g1 and T g2 . Similar changes can be observed for I-3 in relation with temperature. Glass transition behavior was evident in the lifetime behavior of polymers. Increases in slope of the lifetime temperature plots were interpreted free-volume cavity expansion as temperature is increased. The intensity responses in the vicinity of the upper glass transition were consistent with the association of this transition with the reduction of crystalline constraint of segmental mobility in the amorphous phase. (Author)

  4. Migration of plasticizers from poly(vinyl chloride) and multilayer infusion bags using selective extraction and GC-MS.

    Science.gov (United States)

    Haned, Zohra; Moulay, Saad; Lacorte, Silvia

    2018-04-12

    Flexible poly(vinyl chloride) (PVC) is widely used in the pharmaceutical industry for the manufacture of medical devices (tubes, probes, bags, primary packaging, etc.). The objective of the present study was to develop a procedure to evaluate the migration potential of nine plastic additives in aqueous infusion bags (NaCl 0.9% and glucose 5%): five phthalates, one adipate, two alkylphenols, and benzophenone. Two types of materials were analyzed: (i) new and outdated plasticized PVC (containing 40% of diethylhexyl phthalate DEHP); and (ii) tri-laminate polyethylene-polyamide-polypropylene, a multilayer material presumably exempt from DEHP. In addition, we evaluated the migration of plasticizers from PVC raw materials (film and grain) under controlled conditions to compare the migration levels according to Regulation 2011/10. Solid phase extraction and liquid-liquid extraction with gas-chromatography coupled to mass spectrometry were used in all tests. The migration of DEHP in PVC grain exceeded the maximum regulated level of 5000 μg/kg, whereas the levels were much lower in films. In new PVC bags, DEHP was the only compound detected at 4.31 ± 0.5 μg/L in NaCl 0.9% and 4.29 ± 0.25 μg/L in glucose 5% serums, whereas the levels increased 10 times in three-year shelf-life bags. In multilayer bags, DEHP was not found but instead, two plasticizers were detected namely dibuthylphthalate (DBP) and diethylphthalate (DEP) at 0.7 ± 0.1 μg/L and 4.14 ± 0.6 μg/L, respectively. These plasticizers are not mentioned as additives allowed in materials intended for parenteral use (European Pharmacopoeia 8.0, 3.1.5. and 3.1.6.). Caprolactam was tentatively identified and could have stemmed from the polyamide of the multilayer composite. The levels of phthalates remained low but not negligible and might constitute a risk to public health in the case of reiterative infusions. Copyright © 2018. Published by Elsevier B.V.

  5. Palladium Nanoparticles Immobilized on Poly(vinyl chloride-Supported Pyridinium as an Efficient and Recyclable Catalyst for Suzuki-Miyaura Cross-Coupling Reaction

    Directory of Open Access Journals (Sweden)

    Bo Zhou

    2011-01-01

    Full Text Available The palladium nanoparticles immobilized on the polymeric surface of poly(vinyl chloride-supported pyridinium (PVC-Py-Pd0 were achieved by a simple procedure by applying the corresponding functionalized polymer and palladium chloride in ethanol solution. The as-prepared catalyst (PVC-Py-Pd0 was found to be air and moisture stable and exhibits significant catalytic activity for Suzuki-Miyaura cross-coupling reaction of various aryl halides and phenylboronic acid under milder operating conditions. The procedure presented here showed several merits such as short reaction time, simple experimental and isolated procedure and excellent yields of products. Furthermore, the catalyst can be easily recovered and reused for at least six times with consistent activities.

  6. Preparation of robust braid-reinforced poly(vinyl chloride) ultrafiltration hollow fiber membrane with antifouling surface and application to filtration of activated sludge solution.

    Science.gov (United States)

    Zhou, Zhuang; Rajabzadeh, Saeid; Fang, Lifeng; Miyoshi, Taro; Kakihana, Yuriko; Matsuyama, Hideto

    2017-08-01

    Braid-reinforced hollow fiber membranes with high mechanical properties and considerable antifouling surface were prepared by blending poly(vinyl chloride) (PVC) with poly(vinyl chloride-co-poly(ethylene glycol) methyl ether methacrylate) (poly(VC-co-PEGMA)) copolymer via non-solvent induced phase separation (NIPS). The tensile strength of the braid-reinforced PVC hollow fiber membranes were significantly larger than those of previously reported various types of PVC hollow fiber membranes. The high interfacial bonding strength indicated the good compatibility between the coating materials and the surface of polyethylene terephthalate (PET)-braid. Owing to the surface segregation phenomena, the membrane surface PEGMA coverage increased upon increasing the poly(VC-co-PEGMA)/PVC blending ratio, resulting in higher hydrophilicities and bovine serum albumin (BSA) repulsion. To compare the fouling properties, membranes with similar PWPs were prepared by adjusting the dope solution composition to eliminate the effect of hydrodynamic conditions on the membrane fouling performance. The blend membranes surface exhibited considerable fouling resistance to the molecular adsorption from both BSA solution and activated sludge solution. In both cases, the flux recovered to almost 80% of the initial flux using only water backflush. Considering their great mechanical properties and antifouling resistance to activated sludge solution, these novel membranes show good potential for application in wastewater treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Studies on physical properties and fractography of electron beam irradiated poly(vinyl chloride)/epoxidized natural rubber blend in the presence of trimethylolpropane triacrylate

    International Nuclear Information System (INIS)

    Chantara Thevy Ratnam; Khairul Zaman Mohd Dahlan; Nasir, M.; Baharin, A.

    2000-01-01

    The effect of irradiation on the 50/50 poly(vinyl chloride)/epoxidized natural rubber blend was studied in the presence of 3 phr trimethylolpropane triacrylate (TMPTA). The blend was irradiated by using a 3.0 MeV electron beam machine at doses ranging from 20 to 200 kGy in air and room temperature. The tensile properties, resilience and gel fractions of the blends were measured. Electron beam irradiation of the blend in the presence of the TMPTA were found to cause crosslinking which in effect caused an enhancement in modulus and gel fraction together with a concomitant decline in ultimate elongation. The irradiation has resulted in a less hysteretic poly(vinyl chloride)/epoxidized natural rubber blend, with increased rebound resilience. The tensile strength of the blend reached a maximum at 60 kGy followed by a slight decrease at higher doses, implying embrittlement due to the excessive crosslinking. The scanning electron micrographs of the fracture surfaces of the irradiated blends show evidence consistent with the above contention. (Author)

  8. Microwave and ultrasound-assisted synthesis of poly(vinyl chloride)/riboflavin modified MWCNTs: Examination of thermal, mechanical and morphology properties.

    Science.gov (United States)

    Abdolmaleki, Amir; Mallakpour, Shadpour; Azimi, Faezeh

    2018-03-01

    This study focused on the preparation and investigation of physicochemical features of new poly(vinyl chloride) (PVC) nanocomposites (NCs) including different amounts of carboxylated multi-walled carbon nanotubes (MWCNTs-COOH) functionalized with riboflavin (RIB). Firstly, to increase the hydrophilicity of MWCNTs, the surface of them was functionalized by incorporating and formation of ester groups with RIB as a low cost and environmentally friendly biomolecule through ultrasound and microwave irradiations. Afterwards, PVC/RIB-MWCNTs NCs were fabricated via the solution casting and ultrasonic dispersion methods. Prepared NCs were examined by X-ray diffraction, thermogravimetric analysis, field emission scanning electron microscopy, transmission electron micrograph, and Raman spectroscopy. The PVC/RIB-MWCNTs NCs (12wt%) showed the higher mechanical and thermal behavior as compared to other concentration of MWCNTs. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Effect of electron beam irradiation on the structural properties of poly(vinyl alcohol) formulations with triphenyl tetrazolium chloride dye (TTC)

    Science.gov (United States)

    Ali, Z. I.; Said, Hossam M.; Ali, H. E.

    2006-01-01

    Films of poly(vinyl alcohol) (PVA) composites with triphenyl tetrazolium chloride (TTC) dye were prepared and exposed to various radiation doses delivered by accelerated electrons. The results showed that at a low dose of 50 kGy, the colour difference (Δ E*) of PVA/TTC films was increased by ˜10 times of the initial value. However, the change in colour differences did not go systematically with increasing the TTC content, in which the composite with 1.5 wt% displayed higher value than that with 3.5 wt%. The differential scanning calorimetry (DSC) showed that the presence of the TTC dye caused a depression in the melting point ( Tm) and heat of fusion (Δ Hf) of the PVA bulk polymer. However, the thermogravimetric analysis (TGA) showed that the presence of the TTC dye improved the thermal stability of PVA. Also, the tensile strength at break of PVA/TTC composites was improved after electron beam irradiation.

  10. Water Fastness of Screen Printed Pearl Luster Pigments based on Synthetic and Natural Mica on Polyvinyl Chloride Foil and Rich Mineral Paper

    Directory of Open Access Journals (Sweden)

    Mirica Karlovits

    2013-01-01

    Full Text Available The present study attempts to examine water fastness of screen printed pearl luster pigments based on synthetic and natural mica on polyvinyl chloride foil and Rich Mineral Paper. Three types of pearl luster pigments were used, each different from the other in composition, interference colour and particle size: one pigment based on synthetic mica (Pigment 1 and two pigments based on natural mica (Pigment 2 and Pigment 3. Pearl luster pigments were applied to the printing base (PVC transparent base in 15wt.% concentration and printed by means of screen printing technique. The test of water fastness was made on prints, where the samples were soaked in distilled water for 6 and 12 days. It was established that this water treatment did not have any significant impact on the durability of screen printed pearl luster pigments. The pigments could demonstrate slightly better water fastness after being printed on Rich Mineral Paper.

  11. Surface characterization of poly(vinyl chloride) urinary catheters functionalized with acrylic acid and poly(ethylene glycol) methacrylate using gamma-radiation

    Energy Technology Data Exchange (ETDEWEB)

    Islas, Luisa [Departamento de Química de Radiaciones y Radioquímica, Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Ciudad Universitaria, Mexico D.F. 04510 (Mexico); Ruiz, Juan-Carlos [División de Ciencias Básicas e Ingeniería, Depto. de Ingeniería de Procesos e Hidráulica, Universidad Autónoma Metropolitana-Iztapalapa, Av. San Rafael Atlixco No. 186, 09340 México D.F. (Mexico); Muñoz-Muñoz, Franklin [Facultad de Ingeniería, Arquitectura y Diseño, Universidad Autónoma de Baja California, Carretera Transpeninsular Ensenada-Tijuana 3917, Ensenada, B.C. C.P 22860 (Mexico); Isoshima, Takashi [Nano Medical Engineering Laboratory, RIKEN, 2-1Hirosawa, Wako, Saitama 351-0198 (Japan); Burillo, Guillermina, E-mail: burillo@nucleares.unam.mx [Departamento de Química de Radiaciones y Radioquímica, Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Ciudad Universitaria, Mexico D.F. 04510 (Mexico)

    2016-10-30

    Highlights: • Polymer grafting using gamma-radiation allowed for acrylic acid and poly(ethylene glycol) methacrylate to graft on the inner and outer surface of poly(vinyl chloride) urinary catheters. • HR-XPS revealed the different compositional percentages of the compounds present on the surface of the catheter. • Catheters that were grafted with PEGMA had the roughest surface as observed using scanning electron microscopy (SEM) and confocal laser microscopy (CLM). - Abstract: Poly(vinyl chloride) (PVC) urinary catheters were modified with either a single or binary graft of acrylic acid (AAc) and/or poly(ethylene glycol) methacrylate (PEGMA) using gamma-radiation from {sup 60}Co to obtain PVC-g-AAc, PVC-g-PEGMA, [PVC-g-AAc]-g-PEGMA, and [PVC-g-PEGMA]-g-AAc copolymers. The outer and inner surfaces of the modified catheters were characterized using scanning electron microscopy (SEM), confocal laser microscopy (CLM) and X-ray photoelectron spectroscopy (XPS). The XPS analyses, by examining the correlation between the variation of the C{sub 1s} and O{sub 1s} content at the catheter’s surface, revealed that the catheter’s surfaces were successfully grafted with the chosen compounds, with those that were binary grafted showing a slightly more covered surface as was evidenced by the disappearance of PVC’s Cl peak. The SEM and CLM analyses revealed that catheters that had been grafted with PEGMA had a rougher outer surface as compared to those that had only been grafted with AAc. In addition, these imaging techniques showed that the inner surface of the singly grafted catheters, whether they had been grafted with AAc or PEGMA, retained some smoothness at the analyzed grafting percentages, while the binary grafted catheters showed many protuberances and greater roughness on both outer and inner surfaces.

  12. Comparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia.

    Directory of Open Access Journals (Sweden)

    Ata Mahmoodpoor

    2013-07-01

    Full Text Available Because microaspiration of contaminated supraglottic secretions past the endotracheal tube cuff is considered to be central in the pathogenesis of pneumonia, improved design of tracheal tubes with new cuff material and shape have reduced the size and number of folds, which together with the addition of suction ports above the cuff to drain pooled subglottic secretions leads to reduced aspiration of oropharyngeal secretions. So we conducted a study to compare the prophylactic effects of polyurethane-cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes (ETT on ventilator-associated pneumonia. This randomized clinical trial was carried out in a 12 bed surgical intensive care unit. 96 patients expected to require mechanical ventilation more than 96 hours were randomly allocated to one of three following groups: Polyvinyl chloride cuff (PCV ETT, Polyurethane (PU cylindrical Sealguard ETT and PU Taperguard ETT. Cuff pressure monitored every three hours 3 days in all patients. Mean cuff pressure didn't have significant difference between three groups during 72 hours. Pneumonia was seen in 11 patients (34% in group PVC, 8 (25% in Sealguard and 7 (21% in Taperguard group. Changes in mean cuff pressure between Sealguard and PVC tubes and also between Taperguard and PVC tubes did not show any significant difference. There was no significant difference in overinflation between three groups. The use of ETT with PU material results in reducing ventilator-associated pneumonia compared to ETT with PVC cuff. In PU tubes Taperguard has less incidence of ventilator-associated pneumonia compared to Sealguard tubes.

  13. Optimization of the thickness of a conducting polymer, polyaniline, deposited on the surface of poly(vinyl chloride) membranes: a new way to improve their potentiometric response.

    Science.gov (United States)

    Shishkanova, T V; Matejka, P; Král, V; Sedenková, I; Trchová, M; Stejskal, J

    2008-08-29

    Repeated depositions of polyaniline (PANI) have been used to control the thickness of the polymeric film deposited on poly(vinyl chloride) (PVC) membrane surface. The oxidation of aniline was carried out in a dispersion mode, i.e. in the presence of poly(N-vinylpyrrolidone) (PVP). Two kinds of PVC were used for this purpose: a non-plasticized PVC for the study of PANI deposition and PVC, plasticized with nitrophenyl octyl ether (NPOE), as a prototype of a liquid membrane electrode. The results of UV-visible and FTIR spectroscopies and electron microscopy showed that (1) the film thickness increased by about equal increments of approximately 40 nm after each polymerization, and (2) the interface with PVC was constituted by PANI film and adhering PANI-PVP colloidal particles. The various thicknesses of the deposited PANI films affected the potentiometric response of the NPOE/PVC membrane with and without an anion-exchanger. The potentiometric anionic response was observed with a minimal thickness of PANI film on the blank NPOE/PVC membrane. Sensitivity of the PANI film to pH occurred only with a blank NPOE/PVC membrane coated with a thick polymeric film, while it was strongly suppressed by the presence of a lipophilic anion-exchanger, tridodecylmethylammonium chloride (TDDMACl), in the membrane, regardless of the thickness of the polymer film. The thickness of the PANI film did not affect the anionic selectivity pattern of TDDMACl-based membranes to any great extent, but its presence improved and stabilized their potentiometric characteristics (sensitivity, linear-response range).

  14. Occupational exposures at a polyvinyl chloride production facility are associated with significant changes to the plasma metabolome

    International Nuclear Information System (INIS)

    Guardiola, John J.; Beier, Juliane I.; Falkner, K. Cameron; Wheeler, Benjamin; McClain, Craig James; Cave, Matt

    2016-01-01

    Background: Occupational vinyl chloride (VC) exposures have been associated with toxicant-associated steatohepatitis and liver cancer. Metabolomics has been used to clarify mode of action in drug-induced liver injury but has not been performed following VC exposures. Methods: Plasma samples from 17 highly exposed VC workers without liver cancer and 27 unexposed healthy volunteers were obtained for metabolite extraction and GC/MS and LC/MS 2 analysis. Following ion identification/quantification, Ingenuity pathway analysis was performed. Results: 613 unique named metabolites were identified. Of these, 189 metabolites were increased in the VC exposure group while 94 metabolites were decreased. Random Forest analysis indicated that the metabolite signature could separate the groups with 94% accuracy. VC exposures were associated with increased long chain (including arachidonic acid) and essential (including linoleic acid) fatty acids. Occupational exposure increased lipid peroxidation products including monohydroxy fatty acids (including 13-HODE); fatty acid dicarboxylates; and oxidized arachidonic acid products (including 5,9, and 15-HETE). Carnitine and carnitine esters were decreased, suggesting peroxisomal/mitochondrial dysfunction and alternate modes of lipid oxidation. Differentially regulated metabolites were shown to interact with extracellular-signal-regulated kinase 1/2 (ERK1/2), Akt, AMP-activated protein kinase (AMPK), and the N-Methyl-D-aspartate (NMDA) receptor. The top canonical pathways affected by occupational exposure included tRNA charging, nucleotide degradation, amino acid synthesis/degradation and urea cycle. Methionine and homocysteine was increased with decreased cysteine, suggesting altered 1-carbon metabolism. Conclusions: Occupational exposure generated a distinct plasma metabolome with markedly altered lipid and amino acid metabolites. ERK1/2, Akt, AMPK, and NMDA were identified as protein targets for vinyl chloride toxicity. - Highlights:

  15. Occupational exposures at a polyvinyl chloride production facility are associated with significant changes to the plasma metabolome

    Energy Technology Data Exchange (ETDEWEB)

    Guardiola, John J. [University of Louisville Department of Medicine, Louisville, KY 40206 (United States); Beier, Juliane I. [Department of Pharmacology and Toxicology, Louisville, KY 40206 (United States); Falkner, K. Cameron; Wheeler, Benjamin [Department of Medicine, Division of Gastroenterology, Hepatology, and Nutrition, Louisville, KY 40206 (United States); McClain, Craig James [Department of Pharmacology and Toxicology, Louisville, KY 40206 (United States); Department of Medicine, Division of Gastroenterology, Hepatology, and Nutrition, Louisville, KY 40206 (United States); The Robley Rex Veterans Affairs Medical Center, Louisville, KY, 40206 (United States); The Kentucky One Health Jewish Hospital Liver Transplant Program, Louisville, KY 40202 (United States); Cave, Matt, E-mail: matt.cave@louisville.edu [Department of Pharmacology and Toxicology, Louisville, KY 40206 (United States); Department of Medicine, Division of Gastroenterology, Hepatology, and Nutrition, Louisville, KY 40206 (United States); The Robley Rex Veterans Affairs Medical Center, Louisville, KY, 40206 (United States); The Kentucky One Health Jewish Hospital Liver Transplant Program, Louisville, KY 40202 (United States); Department of Biochemistry and Molecular Biology, Louisville, KY, 40202 (United States)

    2016-12-15

    Background: Occupational vinyl chloride (VC) exposures have been associated with toxicant-associated steatohepatitis and liver cancer. Metabolomics has been used to clarify mode of action in drug-induced liver injury but has not been performed following VC exposures. Methods: Plasma samples from 17 highly exposed VC workers without liver cancer and 27 unexposed healthy volunteers were obtained for metabolite extraction and GC/MS and LC/MS{sup 2} analysis. Following ion identification/quantification, Ingenuity pathway analysis was performed. Results: 613 unique named metabolites were identified. Of these, 189 metabolites were increased in the VC exposure group while 94 metabolites were decreased. Random Forest analysis indicated that the metabolite signature could separate the groups with 94% accuracy. VC exposures were associated with increased long chain (including arachidonic acid) and essential (including linoleic acid) fatty acids. Occupational exposure increased lipid peroxidation products including monohydroxy fatty acids (including 13-HODE); fatty acid dicarboxylates; and oxidized arachidonic acid products (including 5,9, and 15-HETE). Carnitine and carnitine esters were decreased, suggesting peroxisomal/mitochondrial dysfunction and alternate modes of lipid oxidation. Differentially regulated metabolites were shown to interact with extracellular-signal-regulated kinase 1/2 (ERK1/2), Akt, AMP-activated protein kinase (AMPK), and the N-Methyl-D-aspartate (NMDA) receptor. The top canonical pathways affected by occupational exposure included tRNA charging, nucleotide degradation, amino acid synthesis/degradation and urea cycle. Methionine and homocysteine was increased with decreased cysteine, suggesting altered 1-carbon metabolism. Conclusions: Occupational exposure generated a distinct plasma metabolome with markedly altered lipid and amino acid metabolites. ERK1/2, Akt, AMPK, and NMDA were identified as protein targets for vinyl chloride toxicity

  16. Stereodynamic insight into the thermal history effects on poly(vinyl chloride) calorimetric sub-glass and glass transitions as a fragile glass model.

    Science.gov (United States)

    Pin, Jean-Mathieu; Behazin, Ehsan; Misra, Manjusri; Mohanty, Amar

    2018-05-02

    The dynamic thermal history impact of poly(vinyl chloride) (PVC) has been explored for a wide range of pre-cooling rates, from 1 to 30 °C min-1. A first macroscopic insight into the dynamic thermal history influence has been highlighted through a decrease in the apparent activation energy (Eapp) in the first stage of the glass transition. The overall glass transition Eapp surface was successfully modeled in a polynomial fashion regarding the pre-cooling range. Raman scattering was used to associate the Eapp variations along the glass transition conversion with the stereochemistry evolution during the polymeric relaxation. Herein, the selection of atactic PVC as the polymer model permits us to monitor the glassy polymer segment stereodynamics during the heating ramp through the C-Cl stretching. The intermolecular H-Cl dipole interactions, as well as intramolecular conformational reorganizations among syndiotactic, isotactic and heterotactic polymer sequences, have been associated with non-cooperative and cooperative motions, i.e. the β- and α-process, respectively. The fruitful comparison of the two extreme values of the pre-cooling rates permits us to propose a thermokinetic scenario that explains the occurrence, intensity, and inter-dependence of β- and α-processes in the glassy state and during the glass transition. This scenario could potentially be generalized to all the other polymeric glass-formers.

  17. High photocatalytic degradation activity of the polyvinyl chloride (PVC)-vitamin C (VC)-TiO{sub 2} nano-composite film

    Energy Technology Data Exchange (ETDEWEB)

    Yang Changjun; Gong Chuqing; Peng Tianyou [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Deng Kejian [Key Laboratory of Catalysis and Materials Science of the State Ethnic Affairs Commission and Ministry of Education, South-Central University for Nationalities, Wuhan 430074 (China); Zan Ling, E-mail: irlab@whu.edu.cn [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)

    2010-06-15

    A novel photodegradable polyvinyl chloride (PVC)-vitamin C (VC)-TiO{sub 2} nano-composite film was prepared by embedding VC modified nano-TiO{sub 2} photocatalyst into the commercial PVC plastic. The solid-phase photocatalytic degradation behavior of PVC-VC-TiO{sub 2} nano-composite film under UV light irradiation was investigated and compared with those of the PVC-TiO{sub 2} film and the pure PVC film, with the aid of UV-Vis spectroscopy, scanning electron microscopy (SEM), weight loss monitoring, and X-ray diffraction spectra (XRD). The results show that PVC-VC-TiO{sub 2} nano-composite film has a high photocatalytic activity; the photocatalytic degradation rate of it is two times higher than that of PVC-TiO{sub 2} film and fifteen times higher than that of pure PVC film. The optimal mass ratio of VC to TiO{sub 2} is found to be 0.5. The mechanism of enhancing photocatalytic activity is attributed to the formation of a Ti{sup IV}-VC charge-transfer complex with five-member chelate ring structure and a rapid photogenerated charge separation is thus achieved.

  18. Preparation and electrical-property characterization of poly(vinyl chloride)-derived carbon nanosheet by ion beam irradiation-induced carbon clustering and carbonization

    Science.gov (United States)

    Jung, Chan-Hee; Sohn, Joon-Yong; Kim, Hyo-Sub; Hwang, In-Tae; Lee, Hong-Joon; Shin, Junhwa; Choi, Jae-Hak

    2018-05-01

    In this work, we demonstrated that carbon nanosheet (CNS) can easily be produced by a room-temperature, solid-state proton irradiation-induced clustering of poly(vinyl chloride) (PVC) films followed by carbonization. The results of the optical, chemical, and structural analyses revealed that oxidized and sp2-hybridized carbon clusters were effectively created in the PVC thin film by combined dehydrochlorination and inter-coupling reactions during proton irradiation. This was further converted to pseudo-hexagonally-structured nano-crystalline CNS with 2-D symmetry and metallic transporting character by high-temperature treatment. As a result, the CNS exhibited a very high electrical conductivity (587 S/cm) without a significant change in their thickness, a low surface roughness (0.36 nm), and a high work function (5.11 eV). These findings demonstrate that the radiation-based approach opens new avenues for the design and development of 2-D CNS as a graphene allotrope for the application of electronic devices, including field-effect transistors, electric heating devices, biosensors, supercapacitors, and fuel cells.

  19. Anion recognition using newly synthesized hydrogen bonding disubstituted phenylhydrazone-based receptors: poly(vinyl chloride)-based sensor for acetate.

    Science.gov (United States)

    Gupta, Vinod K; Goyal, Rajendra N; Sharma, Ram A

    2008-08-15

    A potentiometric acetate-selective sensor, based on the use of butane-2,3-dione,bis[(2,4-dinitrophenyl)hydrazone] (BDH) as a neutral carrier in poly(vinyl chloride) (PVC) matrix, is reported. Effect of various plasticizers and cation excluder, cetryaltrimethylammonium bromide (CTAB) was studied. The best performance was obtained with a membrane composition of PVC:BDH:CTAB ratio (w/w; mg) of 160:8:8. The sensor exhibits significantly enhanced selectivity toward acetate ions over a wide concentration range 5.0 x 10(-6) to 1.0 x 10(-1)M with a lower detection limit of 1.2 x 10(-6)M within pH range 6.5-7.5 with a response time of Fast and stable response, good reproducibility and long-term stability are demonstrated. The sensor has a response time of 15s and can be used for at least 65 days without any considerable divergence in their potential response. Selectivity coefficients determined with the separate solution method (SSM) and fixed interference method (FIM) indicate that high selectivity for acetate ion. The proposed electrode shows fairly good discrimination of acetate from several inorganic and organic anions. It was successfully applied to direct determination of acetate within food preservatives. Total concentration of acetic acid in vinegar samples were determined by direct potentiometry and the values agreed with those mentioned by the manufacturers.

  20. Discoloration of polyvinyl chloride (PVC) tape as a proxy for water-table depth in peatlands: validation and assessment of seasonal variability

    Science.gov (United States)

    Booth, Robert K.; Hotchkiss, Sara C.; Wilcox, Douglas A.

    2005-01-01

    Summary: 1. Discoloration of polyvinyl chloride (PVC) tape has been used in peatland ecological and hydrological studies as an inexpensive way to monitor changes in water-table depth and reducing conditions. 2. We investigated the relationship between depth of PVC tape discoloration and measured water-table depth at monthly time steps during the growing season within nine kettle peatlands of northern Wisconsin. Our specific objectives were to: (1) determine if PVC discoloration is an accurate method of inferring water-table depth in Sphagnum-dominated kettle peatlands of the region; (2) assess seasonal variability in the accuracy of the method; and (3) determine if systematic differences in accuracy occurred among microhabitats, PVC tape colour and peatlands. 3. Our results indicated that PVC tape discoloration can be used to describe gradients of water-table depth in kettle peatlands. However, accuracy differed among the peatlands studied, and was systematically biased in early spring and late summer/autumn. Regardless of the month when the tape was installed, the highest elevations of PVC tape discoloration showed the strongest correlation with midsummer (around July) water-table depth and average water-table depth during the growing season. 4. The PVC tape discoloration method should be used cautiously when precise estimates are needed of seasonal changes in the water-table.

  1. Preparation and characterization of a magneto-polymeric nanocomposite: Fe 3O 4 nanoparticles in a grafted, cross-linked and plasticized poly(vinyl chloride) matrix

    Science.gov (United States)

    Rodríguez-Fernández, Oliverio S.; Rodríguez-Calzadíaz, C. A.; Yáñez-Flores, Isaura G.; Montemayor, Sagrario M.

    In this work two kind of materials: (1) grafted, cross-linked and plasticized poly(vinyl chloride) (PVC) "plastic films" and (2) magnetic plastic films "magneto-polymeric nanocomposites" were prepared. Precursor solutions or "plastisols" used to obtain the plastic films were obtained by mixing PVC (emulsion grade) as polymeric matrix, di(2-ethylhexyl)phthalate (DOP) as plasticizer, a thermal stabilizer based in Ca/Zn salts, and a cross-linking agent, 3-mercaptopropyltrimethoxysilane (MTMS) or 3-aminopropyltriethoxysilane (ATES), at several concentrations. Flexible films were obtained from the plastisols using static casting. The stress-strain behavior and the gel content (determined by Soxhlet extraction with boiling THF) of the flexible films were measured in order to evaluate the effect of the cross-linking agent and their content on the degree of cross-linking. The magneto-polymeric nanocomposites were obtained by mixing the optimum composition of the plastisols (analyzed previously) with magnetite (Fe 3O 4)-based ferrofluid and DOP. Later, flexible films were obtained by static casting of the plastisol/ferrofluid systems. The magnetic films were characterized by the above-mentioned techniques and X-ray diffraction, vibrating sample magnetometry and thermogravimetrical analysis.

  2. High photocatalytic degradation activity of the polyvinyl chloride (PVC)-vitamin C (VC)-TiO2 nano-composite film

    International Nuclear Information System (INIS)

    Yang Changjun; Gong Chuqing; Peng Tianyou; Deng Kejian; Zan Ling

    2010-01-01

    A novel photodegradable polyvinyl chloride (PVC)-vitamin C (VC)-TiO 2 nano-composite film was prepared by embedding VC modified nano-TiO 2 photocatalyst into the commercial PVC plastic. The solid-phase photocatalytic degradation behavior of PVC-VC-TiO 2 nano-composite film under UV light irradiation was investigated and compared with those of the PVC-TiO 2 film and the pure PVC film, with the aid of UV-Vis spectroscopy, scanning electron microscopy (SEM), weight loss monitoring, and X-ray diffraction spectra (XRD). The results show that PVC-VC-TiO 2 nano-composite film has a high photocatalytic activity; the photocatalytic degradation rate of it is two times higher than that of PVC-TiO 2 film and fifteen times higher than that of pure PVC film. The optimal mass ratio of VC to TiO 2 is found to be 0.5. The mechanism of enhancing photocatalytic activity is attributed to the formation of a Ti IV -VC charge-transfer complex with five-member chelate ring structure and a rapid photogenerated charge separation is thus achieved.

  3. Comparative study on polyvinyl chloride film as flexible substrate for preparing free-standing polyaniline-based composite electrodes for supercapacitors.

    Science.gov (United States)

    Wang, Hongxing; Liu, Dong; Du, Pengcheng; Wei, Wenli; Wang, Qi; Liu, Peng

    2017-11-15

    The free-standing polyaniline (PANI)-based composite film electrodes were prepared with polyvinyl chloride (PVC) and the aniline modified PVC (PVC-An) films as flexible substrates for supercapacitors, via facile in-situ chemical oxidative polymerization of aniline, with conventional chemical oxidative polymerization or rapid-mixing chemical oxidative polymerization technique. Owing to the grafting of PANI from the PVC-An film as substrate and the suppression of the secondary growth of the primary PANI particles in the rapid-mixing chemical oxidative polymerization, the PVC-g-PANI-2 composite film with loose surface possessed better comprehensive performance, accompanying the high specific capacitance (645.3F/g at a current density of 1A/g), good rate capacitance (retaining 63.2% of original value at a current density of 10A/g and 52.0% at a scan rate of 100mV/s), good cycle stability (retaining 83.1% after 1000 cycles) and the improved internal resistance. Besides its excellent flexibility, it could retain 61.2% of its original specific capacitance under the stress of 8.66MPa for 1h, demonstrating a good tensile-resistance. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Viscometric investigation of compatibilization of the poly(vinyl chloride)/poly(ethylene-co-vinyl acetate) blends by terpolymer of maleic anhydride styrene vinyl acetate

    Science.gov (United States)

    İmren, Dilek; Boztuğ, Ali; Yılmaz, Ersen; Zengin, H. Bayram

    2008-11-01

    In this study, a blend of poly(vinyl chloride) (PVC)/ethylene-co-vinyl acetate (EVA) was compatibilized by terpolymer of maleic anhydride-styrene-vinyl acetate (MAStVA) used as a compatibilizer. It was prepared the blends of 50/50 PVC/EVA containing 2-10% of the terpolymer. The compatibility experiences of these blends were investigated by using viscometric method in the range of concentrations (0.5-2.0 g dL -1) where tetrahydrofuran (THF) is the solvent. The interaction parameter (Δ b) was used to study the miscibility and compatibility of polymer blend in solution, obtained from the modified Krigbaum and Wall theory. Turbidity and FTIR measurements were also used to investigate the miscibility of this pair of polymers. The values of the relative viscosities of the each polymer solution and their blends were measured by a Cannon-Fenske type viscometer. In consequence of the study, it was observed that a considerable improvement was achieved in the miscibility of PVC/EVA blends by adding among 5 and 10 wt% of compatibilizer.

  5. Effect of Low-Pressure Nitrogen DC Plasma Treatment on the Surface Properties of Biaxially Oriented Polypropylene, Poly (Methyl Methacrylate) and Polyvinyl Chloride Films

    International Nuclear Information System (INIS)

    Mortazavi, S. Hamideh; Ghoranneviss, Mahmood; Pilehvar, Soheil; Esmaeili, Sina; Zargham, Shamim; Hashemi, S. Ebrahim; Jodat, Hamzeh

    2013-01-01

    In this study, commercial biaxially oriented polypropylene (BOPP), polyvinyl chloride (PVC) and poly (methyl methacrylate) (PMMA) films were treated with nitrogen plasma over different exposure times in a Pyrex tube surrounded by a DC variable magnetic field. The chemical changes that appeared on the surface of the samples were investigated using Fourier transform infrared (FT-IR) spectroscopy and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy after treatment for 2 min, 4 min and 6 min in a nitrogen plasma chamber. Effects of the plasma treatment on the surface topographies and contact angles of the untreated and plasma treated films were also analyzed by atomic force microscopy (AFM) and a contact angle measuring system. The results show that the plasma treated films become more hydrophilic with an enhanced wettability due to the formation of some new polar groups on the surface of the treated films. Moreover, at higher exposure times, the total surface energy in all treated films increased while a reduction in contact angle occurred. The behavior of surface roughness in each sample was completely different at higher exposure times. (plasma technology)

  6. Synthesis and characterization of foldable and magnetic field-sensitive, freestanding poly(vinyl acetate)/poly(vinyl chloride)/polyfuran composite and nanocomposite films

    Energy Technology Data Exchange (ETDEWEB)

    Sarıtaş, Sevilay; Eşsiz, Serpil; Sarı, Bekir, E-mail: bsari@gazi.edu.tr

    2017-07-01

    Highlights: • In this study, ternary composite/nanocomposite films were synthesized. • Magnetic field-sensitive folding films were prepared without any elastomer. • Morphological studies show that all composite films have a smooth surface. • The ternary composites/nanocomposite show improved thermal stability compared to the pure PF. - Abstract: In this study, polyfuran and poly(vinyl acetate)/poly(vinyl chloride)/polyfuran ternary composites were synthesized via the chemical polymerization method. The temperature and magnetic field–sensitive novel composites and the nanocomposite were obtained in the form of powders and films. It was observed that the prepared novel conductive films have superior properties at a certain temperature range (25–50 °C) such as bending and folding. The structural properties, thermal behavior, surface morphology, internal structure, and surface roughness of the prepared samples were investigated by various characterization techniques. The conductivities of the samples were measured at room temperature and different temperatures by the four-point technique. X-ray Diffraction analysis results demonstrated that the PF and composites have an amorphous structure, whereas the nanocomposite is in crystalline form. The saturation magnetization (Ms) values of the magnetite and nanocomposite were found to be 58.9 and 5.3 emu g{sup −1}, respectively. It was found that magnetite-doped nanocomposite has superparamagnetic properties at room temperature.

  7. Investigating the effects of polymer molecular weight and non-solvent content on the phase separation, surface morphology and hydrophobicity of polyvinyl chloride films

    Science.gov (United States)

    Khoryani, Zahra; Seyfi, Javad; Nekoei, Mehdi

    2018-01-01

    The main aim of this research is to study the effects of polymer molecular weight as well as non-solvent concentration on the phase separation, surface morphology and wettability of polyvinyl chloride (PVC) films. Gel permeation chromatography (GPC) results showed that the Mn of the used PVC grades is 6 × 104, 8.7 × 104 and 1.26 × 105 g/mol. It was found that a proper combination of polymer molecular weight and non-solvent content could result in superhydrophobic and self-cleaning behaviors. Scanning electron microscopy (SEM) results demonstrated that addition of ethanol causes the polymer chains to be severely aggregated at the films' surface forming strand-like structures decorated by nano-scale polymer spheres. The polymer molecular weight was found to affect the degree of porosity which is highly influential on the hydrophobicity of the films. The mechanism of phase separation process was also discussed and it was found that the instantaneous demixing is the dominant mechanism once higher contents of non-solvent were used. However, a delayed demixing mechanism was detected when the lower molecular weight PVC has been used which resulted in a pore-less and dense skin layer. Differential scanning calorimetry was also utilized to study the crystallization and glass transition behavior of samples.

  8. Poly(vinyl chloride) membrane alkali metal ion-selective electrodes based on crystalline synthetic zeolite of the Faujasite type

    International Nuclear Information System (INIS)

    Aghai, H.; Giahi, M.; Arvand Barmehi, M.

    2002-01-01

    Potentiometric electrodes based on the incorporation of zeolite particle in to poly (vinyl chloride) (pvc) membranes are described. The electrodes characteristics are evaluated regarding the response towards alkali ions. Pvc membranes plasticised with dibutyl phthalate and without lipophilic additives (co-exchanger) were used throughout this study. The electrode exhibits a Nernst ion response over the alkali metal cations concentration a range of 1.0x10 - 4 - 1.0 x 10 1 M with a slop of 57.0 ± 0.9 mV per decade of concentration a working ph range (3.0- 9.0) and a fast response time (≤15 c). The selective coefficients for cesium ion as test species with respect to alkaline earth, ammonium and some heavy metal ions were determined. Zeolite-PVC electrodes were applied to the determination of ionic surfactant

  9. Covalent immobilization of lipase, glycerol kinase, glycerol-3-phosphate oxidase & horseradish peroxidase onto plasticized polyvinyl chloride (PVC strip & its application in serum triglyceride determination

    Directory of Open Access Journals (Sweden)

    Nidhi Chauhan

    2014-01-01

    Full Text Available Background & objectives:Reusable biostrip consisting enzymes immobilized onto alkylamine glass beads affixed on plasticized PVC strip for determination of triglyceride (TG suffers from high cost of beads and their detachments during washings for reuse, leading to loss of activity. The purpose of this study was to develop a cheaper and stable biostrip for investigation of TG levels in serum. Methods: A reusable enzyme-strip was prepared for TG determination by co-immobilizing lipase, glycerol kinase (GK, glycerol-3-phosphate oxidase (GPO and peroxidase (HRP directly onto plasticized polyvinyl chloride (PVC strip through glutaraldehyde coupling. The method was evaluated by studying its recovery, precision and reusability. Results: The enzyme-strip showed optimum activity at pH 7.0, 35 o C and a linear relationship between its activity and triolein concentration in the range 0.1 to 15 mM. The strip was used for determination of serum TG. The detection limit of the method was 0.1 mM. Analytical recovery of added triolein was 96 per cent. Within and between batch coefficients of variation (CV were 2.2 and 3.7 per cent, respectively. A good correlation (r=0.99 was found between TG values by standard enzymic colrimetric method employing free enzymes and the present method. The strip lost 50 per cent of its initial activity after its 200 uses during the span of 100 days, when stored at 4 o C. Interpretation & conclusions: The nitrating acidic treatment of plasticized PVC strip led to glutaraldehyde coupling of four enzymes used for enzymic colourimetric determination of serum TG. The strip provided 200 reuses of enzymes with only 50 per cent loss of its initial activity. The method could be used for preparation of other enzyme strips also.

  10. Innovative leaching of cobalt and lithium from spent lithium-ion batteries and simultaneous dechlorination of polyvinyl chloride in subcritical water

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Kang; Zhang, Fu-Shen, E-mail: fszhang@rcees.ac.cn

    2016-10-05

    Highlights: • A co-treatment process for recovery of Co and Li and simultaneous detoxification of PVC in subcritical water was proposed. • PVC was used as a hydrochloric acid source. • More than 95% Co and nearly 98% Li were leached under the optimum conditions. • Neither corrosive acid nor reducing agent was used. • The co-treatment process has technical, economic and environmental benefits over the traditional recovery processes. - Abstract: In this work, an effective and environmentally friendly process for the recovery of cobalt (Co) and lithium (Li) from spent lithium-ion batteries (LIBs) and simultaneously detoxification of polyvinyl chloride (PVC) in subcritical water was developed. Lithium cobalt oxide (LiCoO{sub 2}) power from spent LIBs and PVC were co-treated by subcritical water oxidation, in which PVC served as a hydrochloric acid source to promote metal leaching. The dechlorination of PVC and metal leaching was achieved simultaneously under subcritical water oxidation. More than 95% Co and nearly 98% Li were recovered under the optimum conditions: temperature 350 °C, PVC/LiCoO{sub 2} ratio 3:1, time 30 min, and a solid/liquid ratio 16:1 (g/L), respectively. Moreover, PVC was completely dechlorinated at temperatures above 350 °C without any release of toxic chlorinated organic compounds. Assessment on economical and environmental impacts revealed that the PVC and LiCoO{sub 2} subcritical co-treatment process had significant technical, economic and environmental benefits over the traditional hydrometallurgy and pyrometallurgy processes. This innovative co-treatment process is efficient, environmentally friendly and adequate for Co and Li recovery from spent LIBs and simultaneous dechlorination of PVC in subcritical water.

  11. Influence of fiber content on mechanical, morphological and thermal properties of kenaf fibers reinforced poly(vinyl chloride)/thermoplastic polyurethane poly-blend composites

    International Nuclear Information System (INIS)

    El-Shekeil, Y.A.; Sapuan, S.M.; Jawaid, M.; Al-Shuja’a, O.M.

    2014-01-01

    Highlights: • Increasing fiber content decreased tensile strength and strain. • Tensile modulus was increasing with increase in fiber content. • SEM showed fiber/matrix poor adhesion. • Impact strength was decreasing with increase in fiber content. • Lower thermal stability with increase in fiber content was observed. - Abstract: Kenaf (Hibiscus Cannabinus) bast fiber reinforced poly(vinyl chloride) (PVC)/thermoplastic polyurethane (TPU) poly-blend was prepared by melt mixing method using Haake Polydrive R600 internal mixer. The composites were prepared with different fiber content: 20%, 30% and 40% (by weight), with the processing parameters: 140 °C, 11 min, and 40 rpm for temperature, time and speed, respectively. After mixing, the composite was compressed using compressing molding machine. Mechanical properties (i.e. tensile properties, flexural properties, impact strength) were studied. Morphological properties of tensile fracture surface were studied using Scanning electron microscope (SEM). Thermal properties of the composites were studied using Thermogravimetric Analyses (TGA). PVC/TPU/KF composites have shown lower tensile strength and strain with increase in fiber content. Tensile modulus showed an increasing trend with increase in fiber content. Impact strength decreased with increase in fiber content; however, high impact strength was observed even with 40% fiber content (20.2 kJ/m 2 ). Mean while; the 20% and 30% fiber contents showed higher impact strength of 34.9, 27.9 kJ/m 2 ; respectively. SEM showed that there is poor fiber/matrix adhesion. Thermal degradation took place in three steps. In the first step, composites as well as the matrix had a similar stability. At the second step, matrix showed a slightly better stability than the composites. At the last step, composites showed a better stability than the matrix

  12. Improved permeation performance and fouling-resistance of Poly(vinyl chloride/Polycarbonate blend membrane with added Pluronic F127

    Directory of Open Access Journals (Sweden)

    Supateekan Pacharasakoolchai

    2014-04-01

    Full Text Available The aim of this work was to prepare and characterize poly(vinyl chloride (PVC/polycarbonate (PC blend membranes for use in ultrafiltration. Pluronic F127 was used as an additive to modify the membrane surface of the PVC/PC blended membranes. The PVC/PC blend membrane was first prepared using the phase inversion method from a casting solution of PVC with small amount of PC in N-methylpyrrolidone (NMP and water as the non-solvent. The morphologies structure and properties, such as tensile strength, water flux, and bovine serum albumin (BSA rejection of the blend membrane were studied. Increased amounts of PC resulted in an increase in the water flux and ability to reject protein. A concentration of 0.75 wt% PC provided the best improvement in tensile strength of blend membrane. Addition of different amounts of pluronic F127 to the casting solution of PVC/PC with a PC concentration of 0.75 wt% resulted in a decrease in the water contact angle that demonstrated the improvement of hydrophilicity of blend membrane. Scanning electron microscopy photographs showed that the modified PVC/PC membranes had a bigger pore volume in the porous sub-layer compared to the PVC/PC control membrane. The PVC/PC membrane with added Pluronic F127 exhibited a much higher flux and rejection of BSA in a protein filtration experiment than the PVC/PC membrane. An increase in flux recovery ratio of PVC/PC/pluronic 127 blend membrane indicated that the modified membranes could reduce membrane fouling useful for ultrafiltration.

  13. In vitro evaluation of di(2-ethylhexyl)terephthalate-plasticized polyvinyl chloride blood bags for red blood cell storage in AS-1 and PAGGSM additive solutions.

    Science.gov (United States)

    Graminske, Sharon; Puca, Kathleen; Schmidt, Anna; Brooks, Scott; Boerner, Amanda; Heldke, Sybil; de Arruda Indig, Monika; Brucks, Mark; Kossor, David

    2018-05-01

    Di(2-ethylhexyl)phthalate (DEHP) makes polyvinyl chloride flexible for use in blood bags and stabilizes the red blood cell (RBC) membrane preventing excessive hemolysis. DEHP migrates into the blood product and rodent studies have suggested that DEHP exposure may be associated with adverse health effects albeit at high dosages. Although structurally and functionally similar to DEHP, di(2-ethylhexyl)terephthalate (DEHT; or Eastman 168 SG [Eastman Chemical Company]) is metabolically distinct with a comprehensive and benign toxicology profile. This study evaluated RBC stability in DEHT-plasticized bags with AS-1 and PAGGSM compared to conventional DEHP-plasticized bags with AS-1. Thirty-six whole blood units were collected into CPD solution, leukoreduced, centrifuged, and divided into RBCs and plasma. To limit donor-related variability, three ABO-identical RBCs were mixed together and then divided equally and stored among the three different plasticizer and additive solution combinations. RBCs from 12 trios were analyzed for a standard panel of in vitro variables on Day 0 and after storage. No individual bag on Day 42 exceeded the US 1.0% hemolysis criteria. While hemolysis during storage was higher in the DEHT bags, the PAGGSM RBCs were close to the control RBCs (0.38% vs. 0.32%, respectively). ATP retention was higher than 70% and potassium levels were similar regardless of plasticizer. Additional RBC variables exhibited some significant differences but were not viewed as clinically important. DEHT/PAGGSM provides similar hemolysis protection to that of DEHP/AS-1. Although hemolysis values with DEHT and AS-1 are higher than that of DEHP, DEHT is a potential DEHP alternative. © 2018 AABB.

  14. Adsorption of recombinant human granulocyte colony stimulating factor (rhG-CSF) to polyvinyl chloride, polypropylene, and glass: effect of solvent additives.

    Science.gov (United States)

    Johnston, T P

    1996-01-01

    The adsorption of recombinant-derived proteins to glass and polymeric materials used in their packaging and delivery remains a problem. Loss of these very expensive proteins to surface adsorption not only results in reduced yields during purification and scale-up, but also to decreased therapeutic efficacy. The purpose of the present investigation was to inhibit/minimize adsorption of a model protein, namely, recombinant human granulocyte colony stimulating factor (rhG-CSF) to glass, polyvinyl chloride (PVC), and polypropylene by inclusion of select solvent additives. Solvent additives used to inhibit/minimize surface adsorption included glycerin, U.S.P. (0.5%, 1%, 5%, and 25% v/v), Pluronic F-127 (0.005%, 0.05%, and 0.5% w/w), Pluronic F-68 (0.005%, 0.05%, and 0.5% w/w), Tween 80 (0.005% and 0.05% w/w) and Tween 20 (0.005%, 0.05%, and 0.5% w/w). Over the rhG-CSF concentration range of 0.0 ng/ml to 300 ng/ml, the amount of rhG-CSF bound per cm2 of PVC increased with an increase in the rhG-CSF concentration tested. At rhG-CSF equilibrium concentrations of 262 +/- 3.7 ng/ml and 136 +/- 1.9 ng/ml, the rhG-CSF bound/cm2 of PVC at 22 degrees C and 45 degrees C reached a maximum of 37.6 +/- 9.8 ng/cm2 and 165.2 +/- 11.7 ng/cm2, respectively. The adsorption isotherms determined at each temperature were described by the classic Freundlich equation. Moreover, the rate of adsorption of rhG-CSF to PVC was extremely rapid. The mean values of the percent of rhG-CSF bound to PVC after only 10 minutes of equilibration at 22 degrees C and 45 degrees C were 92.8 +/- 9.2 percent and 97.3 +/- 17.9 percent, respectively. The mean values of the percent of rhG-CSF bound to PVC at 22 degrees C and 45 degrees C after 24 hours were 52.4 +/- 10.9% and 70.0 +/- 9.7%, respectively, indicating that some desorption of rhG-CSF does occur during 24 hr. However, surface adsorption of rhG-CSF to PVC was shown to be irreversible over a 1 hr time period. Using viscometry, an estimate of the thickness

  15. Active film of poly(vinyl chloride)/silver: synthesis, characterization and evaluation as antimicrobial active packaging; Filme ativo de poli(cloreto de vinila)/prata: sintese, caracterizacao e avaliacao como embalagem ativa antimicrobiana

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Lilian R.; Rangel, Ellen T.; Machado, Fabricio, E-mail: lilianrodribraga@gmail.com [Universidade de Brasilia (UnB), Brasilia, DF, (Brazil)

    2015-07-01

    The antimicrobial films based on poly(vinyl chloride) (PVC) mediated silver (1, 2, 4 and 8 wt%) were evaluated as antimicrobial active packaging using the casting method. The structure of the active films was characterized by SEM, EDX-XRF, XRD, FTIR and TG. FTIR spectra confirmed the PVC-Ag interaction due to the presence of new bands at 1745 cm{sup -1} and 1165 cm{sup -1} bands, which are absent in the PVC control. The FRX-EDX spectrum confirmed the presence of silver ions in all the films. TG and SEM results showed that the increased concentration of silver provided an improved thermal stability and presence of pores in the active films, respectively. Antimicrobial activity was evaluated by disk diffusion method for Bacillus subtilis, Fusarium solani and Apergillus niger, which proved the efficiency of the films active. (author)

  16. Fabrication of 3D interconnected porous TiO{sub 2} nanotubes templated by poly(vinyl chloride-g-4-vinyl pyridine) for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Joo Hwan; Koh, Jong Kwan; Seo, Jin Ah; Kim, Jong Hak [Department of Chemical and Biomolecular Engineering, Yonsei University, 262 Seongsanno, Seodaemun-gu, Seoul 120-749 (Korea, Republic of); Shin, Jong-Shik, E-mail: jonghak@yonsei.ac.kr [Department of Biotechnology, Yonsei University, 262 Seongsanno, Seodaemun-gu, Seoul 120-749 (Korea, Republic of)

    2011-09-07

    Porous TiO{sub 2} nanotube arrays with three-dimensional (3D) interconnectivity were prepared using a sol-gel process assisted by poly(vinyl chloride-graft-4-vinyl pyridine), PVC-g-P4VP graft copolymer and a ZnO nanorod template. A 7 {mu}m long ZnO nanorod array was grown from the fluorine-doped tin oxide (FTO) glass via a liquid phase deposition method. The TiO{sub 2} sol-gel solution templated by the PVC-g-P4VP graft copolymer produced a random 3D interconnection between the adjacent ZnO nanorods during spin coating. Upon etching of ZnO, TiO{sub 2} nanotubes consisting of 10-15 nm nanoparticles were generated, as confirmed by wide-angle x-ray scattering (WAXS), energy-filtering transmission electron microscopy (EF-TEM) and field-emission scanning electron microscopy (FE-SEM). The ordered and interconnected nanotube architecture showed an enhanced light scattering effect and increased penetration of polymer electrolytes in dye-sensitized solar cells (DSSC). The energy conversion efficiency reached 1.82% for liquid electrolyte, and 1.46% for low molecular weight (M{sub w}) and 0.74% for high M{sub w} polymer electrolytes.

  17. The synthesis of poly(vinyl chloride) nanocomposite films containing ZrO2 nanoparticles modified with vitamin B1 with the aim of improving the mechanical, thermal and optical properties.

    Science.gov (United States)

    Mallakpour, Shadpour; Shafiee, Elaheh

    2017-01-01

    In the present investigation, solution casting method was used for the preparation of nanocomposite (NC) films. At first, the surface of ZrO 2 nanoparticles (NPs) was modified with vitamin B 1 (VB 1 ) as a bioactive coupling agent to achieve a better dispersion and compatibility of NPs within the poly(vinyl chloride) (PVC) matrix. The grafting of modifier on the surface of ZrO 2 was confirmed by Fourier transform infrared spectroscopy and thermogravimetric analysis (TGA). Finally, the resulting modified ZrO 2 (ZrO 2 -VB 1 ), was used as a nano-filler and incorporated into the PVC matrix to improve its mechanical and thermal properties. These processes were carried out under ultrasonic irradiation conditions, which is an economical and eco-friendly method. The effect of ZrO 2 -VB 1 on the properties and morphology of the PVC matrix was characterized by various techniques. Field emission scanning electron microscopy and transmission electron microscopy analyses showed a good dispersion of fillers into the PVC matrix with the average diameter of 37-40 nm. UV-Vis spectroscopy was used to study optical behavior of the obtained NC films. TGA analysis has confirmed the presence of about 7 wt% VB 1 on the surface of ZrO 2 . Also, the data indicated that the thermal and mechanical properties of the NC films were enhanced.

  18. Nanocomposite materials based on poly(vinyl chloride) and bovine serum albumin modified ZnO through ultrasonic irradiation as a green technique: Optical, thermal, mechanical and morphological properties.

    Science.gov (United States)

    Mallakpour, Shadpour; Darvishzadeh, Marzieh

    2018-03-01

    In this project, physicochemical properties of poly(vinyl chloride) (PVC) reinforced by ZnO nanoparticles (NPs) were studied. Firstly, ZnO NPs were modified with bovine serum albumin (BSA) as an organo-modifier and biocompatible substance through ultrasound irradiation as environmental friendly, low cost and rapid means. Nanocomposite (NC) films were prepared by loadings of various ratios of ZnO/BSA NPs (3, 6 and 9wt%) inside the PVC. Structural morphology and physical properties of the ZnO-BSA NPs and NC films were investigated via Fourier transform infrared spectroscopy, X-ray diffraction, thermogravimetric analysis (TGA), transmission electron microscopy and field emission scanning electron microscopy. According to the obtained information from the TGA, an increase in the thermal stability can be clearly observed. Also the results of contact angle analysis indicated with increasing percent of ZnO/BSA NPs into PVC the hydrophilic behaviors of NCs were increased. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine

    International Nuclear Information System (INIS)

    Gupta, Vinod Kumar; Singh, A.K.; Gupta, Barkha

    2006-01-01

    A polyvinyl chloride (PVC) based membrane sensor for cerium ions was prepared by employing N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine as an ionophore, oleic acid (OA) as anion excluder and o-nitrophenyloctyl ether (o-NPOE) as plasticizer. The plasticized membrane sensor exhibits a Nernstian response for Ce(III) ions over a wide concentration range (1.41 x 10 -7 to 1.0 x 10 -2 M) with a limit of detection as low as 8.91 x 10 -8 M. It has a fast response time (<10 s) and can be used for 4 months. The sensor revealed a very good selectivity with respect to common alkali, alkaline earth and heavy metal ions. The response of the proposed sensor is independent of pH between 3.0 and 8.0. It was used as an indicator electrode in potentiometric titration of fluoride, carbonate and oxalate anions and determination of cerium in simulated mixtures

  20. Poly(vinyl chloride)-g-poly(2-(dimethylamino)ethyl methacrylate) graft copolymers templated synthesis of mesoporous TiO{sub 2} thin films for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rajkumar; Ahn, Sung Hoon; Seo, Jin Ah; Kim, Sang Jin; Kim, Jong Hak, E-mail: jonghak@yonsei.ac.kr [Yonsei University, Department of Chemical and Biomolecular Engineering (Korea, Republic of)

    2012-07-15

    A poly(vinyl chloride) (PVC) main chain was grafted with poly(2-(dimethylamino)ethyl methacrylate) (PDMAEMA) containing a quaternary amine group using atom transfer radical polymerization. The successful synthesis of a PVC-g-PDMAEMA graft copolymer was confirmed by Fourier transform infrared, nuclear magnetic resonance, thermogravimetric analysis, and transmission electron microscopy. The PVC-g-PDMAEMA graft copolymer was used as a structure-directing agent (SDA) for the fabrication of a mesoporous thin film containing a titanium dioxide (TiO{sub 2}) layer. To control the porosity of the resultant inorganic layer, the ratio of SDA to TTIP as well as the concentration of the sol-gel was varied. The structure and porosity of the mesoporous film were characterized by XRD and SEM analysis. The mesoporous TiO{sub 2} film fabricated on the FTO surface was used as a photoanode for the dye-sensitized solar cell (DSSC). DSSC performance was the greatest when using TiO{sub 2} film with a higher porosity and lower interfacial resistance. The highest energy conversion efficiency reached 3.2 % at 100 mW/cm{sup 2}, which was one of the highest reported values for a quasi-solid-state DSSC with 600-nm-thick TiO{sub 2} film.

  1. Preparation of Chloro Penta Amine Cobalt(III Chloride and Study of Its Influence on the Structural and Some Optical Properties of Polyvinyl Acetate

    Directory of Open Access Journals (Sweden)

    Nada K. Abbas

    2015-01-01

    Full Text Available Chloro penta amine cobalt(III cloride [Co(NH35Cl]Cl2 was prepared and then characterized by Fourier transform infrared spectroscopy and X-ray diffraction. The obtained results indicated the formation of orthorhombic [Co(NH35Cl]Cl2 nanoparticles of ≈28.75 nm size. Polymeric films based on polyvinyl acetate (PVAc doped with chloro penta amine cobalt(III cloride [Co(NH35Cl]Cl2 in different weight percent ratios were prepared using the solvent cast technique. The complexation of the additive with the polymer was confirmed by FTIR and SEM studies. The XRD pattern revealed that the amorphousicity of PVAc polymer matrix increased with raising the [Co(NH35Cl]Cl2 content. Parameters such as extinction coefficient, refractive index, real and imaginary parts, and optical conductivity were studied by using the absorbance and measurements from computerized UV-visible spectrophotometer in the spectral range 190–800 nm. This study showed that the optical properties of PVAc were affected by the doping of [Co(NH35Cl]Cl2 where the absorption increased by leveling up [Co(NH35Cl]Cl2 concentration. The nature of electronic transition from valence band to conduction band was determined and the energy band gaps of the composite films samples were estimated by UV-visible spectrum. It was observed that the optical conductivity increased with photon energy and with the increase of [Co(NH35Cl]Cl2 concentration.

  2. Preparation of a microporous polymer electrolyte based on poly(vinyl chloride)/poly(acrylonitrile-butyl acrylate) blend for Li-ion batteries

    International Nuclear Information System (INIS)

    Tian, Zheng; Pu, Weihua; He, Xiangming; Wan, Chunrong; Jiang, Changyin

    2007-01-01

    Poly(acrylonitrile-co-butyl acrylate) (P(AN-co-BuA))/poly(vinyl chloride) (PVC) blend-based gel polymer electrolyte (BGPE) was prepared for lithium-ion batteries. The P(AN-co-BuA)/PVC BGPE consists of an electrolyte-rich phase, which is mainly composed of P(AN-co-BuA) and liquid electrolyte, acting as a conducting channel and a PVC-rich phase that provides mechanical strength. The dual phase was just simply developed by the difference of miscibility properties in solvent, PC, between P(AN-co-BuA) and PVC. The mechanical strength of this new blend electrolyte was found to be much higher, with a fracture stress as high as 29 MPa in dry membrane and 21 MPa in gel state, than that of a previously reported P(AN-co-BuA)-based gel polymer electrolyte. The blended gel polymer electrolyte showed ionic conductivity of higher than 1.5 x 10 -3 S cm -1 and electrochemical stability up to at least 4.8 V. The results showed that the as-prepared gel polymer electrolytes were promising materials for lithium-ion batteries

  3. Preparation of a microporous polymer electrolyte based on poly(vinyl chloride)/poly(acrylonitrile-butyl acrylate) blend for Li-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Zheng; Pu, Weihua; He, Xiangming; Wan, Chunrong; Jiang, Changyin [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China)

    2007-02-15

    Poly(acrylonitrile-co-butyl acrylate) (P(AN-co-BuA))/poly(vinyl chloride) (PVC) blend-based gel polymer electrolyte (BGPE) was prepared for lithium-ion batteries. The P(AN-co-BuA)/PVC BGPE consists of an electrolyte-rich phase, which is mainly composed of P(AN-co-BuA) and liquid electrolyte, acting as a conducting channel and a PVC-rich phase that provides mechanical strength. The dual phase was just simply developed by the difference of miscibility properties in solvent, PC, between P(AN-co-BuA) and PVC. The mechanical strength of this new blend electrolyte was found to be much higher, with a fracture stress as high as 29 MPa in dry membrane and 21 MPa in gel state, than that of a previously reported P(AN-co-BuA)-based gel polymer electrolyte. The blended gel polymer electrolyte showed ionic conductivity of higher than 1.5 x 10{sup -3} S cm{sup -1} and electrochemical stability up to at least 4.8 V. The results showed that the as-prepared gel polymer electrolytes were promising materials for lithium-ion batteries. (author)

  4. New polyvinyl chloride (PVC) nanocomposite consisting of aromatic polyamide and chitosan modified ZnO nanoparticles with enhanced thermal stability, low heat release rate and improved mechanical properties

    Science.gov (United States)

    Hajibeygi, Mohsen; Maleki, Mahdiye; Shabanian, Meisam; Ducos, Franck; Vahabi, Henri

    2018-05-01

    New ternary nanocomposite systems containing polylvinyl chloride (PVC), chitosan modified ZnO (CMZN) nanoparticles and new synthesized polyamide (PA) were designed and prepared by solution casting method. As a potential reinforcement, CMZN was used in PVC system combined with and without PA. Morphology, mechanical, thermal and combustion properties of the all PVC systems were studied. In the presence of the CMZN, PA showed a synergistic effect on improvement of the all investigated properties of PVC. The 5 mass% loss temperature (T5) was increased from 195 °C to 243 °C in PVC/CMZN-PA nanocomposite containing 1 mass% of each PA and CMZN (PZP 2). The peak of heat release rate was decreased from 131 W/g for PVC to 104 W/g for PVC/CMZN-PA nanocomposite containing 3 mass% of each PA and CMZN (PZP 6). According to the tensile tests, compared to the neat PVC, the tensile strength was increased from 35.4 to 53.4 MPa for PZP 6.

  5. The overall heat transfer of greenhouses covered with PE [polyethylene film] and PVC [polyvinyl chloride film] single layer: The heat insulation efficiency of greenhouses and their covering materials (1)

    International Nuclear Information System (INIS)

    Minagawa, H.; Tachibana, K.

    1982-01-01

    Overall heat transfer of polyethylene film (PE) and polyvinyl chloride film (PVC) were measured in the experimental greenhouses with hot-air heaters on the clear and on the cloudy nights during the period Nov. 1979 to Jan. 1980. Both films are 0.1 mm thick and have different physical properties for long-wave radiation. The heat insulation efficiency of the greenhouses covered with PE and PVC single layer was investigated, and the ratio of floor area to covering area for the experimental greenhouses, which is one of the indices for the heat insulation efficiency of greenhouses, was also taken into consideration. The results are as follows: 1. Using the ratio of the overall heat transfer and the overall heat transfer coefficients for the heat insulation efficiency, the PE-house revealed to be less efficient than the PVC-house. This can be due to PE being more transparent to long-wave radiation than PVC. The advantage in the PVC-house, however, decreased with the increasing of the inside-outside air temperature difference (Figs. 3 and 5). 2. The overall heat transfer coefficients of both greenhouses depended on the inside-outside temperature difference. As the temperature difference increased, the overall heat transfer coefficients decreased (Fig. 5). 3. The overall heat transfer coefficients of both greenhouses were smaller on the cloudy nights than that on the clear nights. When the condensation occurred at the interior film surface, the heat insulation efficiency of both greenhouses was increased, resulting in the decrease of the coefficient. The efficiency of the PE-house was more affected than the PVC-house when the condensation occurred (Figs. 6 and 7). 4. When the inside-outside air temperature difference was small, convective heat transferred from the outside air to the outside cover surface. With an increase in the inside-outside air temperature difference, convective heat flow occurred from the outside cover surface to the outside air. This phenomenon was

  6. Polyvinyl chloride degradation by X-rays

    International Nuclear Information System (INIS)

    Sbampato, M.E.

    1984-01-01

    Degradation of film samples of pure PVC and comercial film (PVC + Polyacrylatis) with vacuum X-rays using the following techniques: infra-red, Raman, ultra violet and visible spectroscopies, eletronic paramagnetic resonance, X-rays difraction, percent measurement of transmitance and microanalysis was studied. (L.M.J.) [pt

  7. Influence of granular strontium chloride as additives on some ...

    Indian Academy of Sciences (India)

    Influence of granular strontium chloride as additives on some electrical and mechanical properties for pure polyvinyl alcohol. A B Elaydy M Hafez ... Keywords. Polyvinyl-alcohol (PVA); granular strontium chloride, SrCl2; a.c. electrical conductivity; dielectric constant; dielectric loss; Young's modulus; creep relaxation curve.

  8. Surface decontamination studies using polyvinyl acetate based strippable polymer

    International Nuclear Information System (INIS)

    Rao, S.V.S.; Lal, K.B.

    2004-01-01

    Polyvinyl acetate based strippable polymer has been developed for surface decontamination. Stainless steel, mild steel, polyvinyl chloride and rubber have been selected as candidate materials for the radioactive decontamination studies. The ease of strippability and homogeneity of the polymer coating has been studied using infrared spectrophotometer. Decontamination of used radioactive respirator has been carried out and the peels obtained have been subjected to leaching and incineration studies. The infrared spectrophotometric studies also have been conducted to study the interaction between polyvinyl acetate and ions, like cesium, strontium and cobalt. (author)

  9. Flexible cryogenic conduit

    International Nuclear Information System (INIS)

    Brindza, P.D.; Wines, R.R.; Takacs, J.J.

    1999-01-01

    A flexible and relatively low cost cryogenic conduit is described. The flexible cryogenic conduit of the present invention comprises a first inner corrugated tube with single braided serving, a second outer corrugated tube with single braided serving concentric with the inner corrugated tube, and arranged outwardly about the periphery of the inner corrugated tube and between the inner and outer corrugated tubes: a superinsulation layer; a one half lap layer of polyester ribbon; a one half lap layer of copper ribbon; a spirally wound refrigeration tube; a second one half lap layer of copper ribbon; a second one half lap layer of polyester ribbon; a second superinsulation layer; a third one half lap layer of polyester ribbon; and a spirally wound stretchable and compressible filament

  10. Facile Preparation of Chloride-Conducting Membranes : First Step towards a Room-Temperature Solid-State Chloride-Ion Battery

    NARCIS (Netherlands)

    Gschwind, Fabienne; Steinle, Dominik; Sandbeck, Daniel; Schmidt, Celine; von Hauff, Elizabeth

    2016-01-01

    Three types of chloride-conducting membranes based on polyvinyl chloride, commercial gelatin, and polyvinyldifluoride-hexafluoropolymer are introduced in this report. The polymers are mixed with chloride-containing salts, such as tetrabutylammonium chloride, and cast to form membranes. We studied

  11. Sealing a conduit end

    International Nuclear Information System (INIS)

    Mentz, R.M.

    1993-01-01

    An apparatus for sealing or blocking conduits, such as the primary nozzles of a nuclear steam generator is described. It includes an annular bracket sealingly attached to the open end of the nozzle, the bracket having a plurality of threaded holes therein. Mounted atop the bracket is a generally circular nozzle dam for covering the opening. Interposed between the nozzle dam and the bracket is an extrusion-resistant seal member having a plurality of apertures therethrough for receiving each bolt. The seal member is configured to resist extrusion by having laminated layers of differing hardnesses, so that the seal member will not laterally extrude away from each bolt in a manner that enlarges the aperture surrounding each bolt as the nozzle dam is bolted to the bracket. (author)

  12. An evaluation of the performance and mechanistic action of the costabiliser N-phenyl-3-acetyl pyrrolidine-2,4-dione and its derivatives in poly(vinyl chloride)

    International Nuclear Information System (INIS)

    Chaudhry, H.I.

    1999-10-01

    N-phenyl-3-acetyl pyrrolidine-2,4-dione (F6) and its derivatives (F6c and F6d) have been investigated as costabilisers for PVC at processing temperatures, along with the commercial costabilisers: dehydroacetic acid (DHA) and Rhodiostab-83 (R83). Spectroscopic (fluorescence, Fourier-transform infrared and nuclear magnetic resonance) studies on PVC itself, and model compounds of PVC impurities (e.g. 4-chloro-2-hexene) have shown two distinct modes of action: in which a metal complex between the costabiliser and a metal soap stabiliser (zinc stearate and calcium stearate is the active entity, one in which costabiliser action is facilitated by release of zinc chloride. F6 was shown to substitute for allylic chloride by a C-alkylation reaction so inhibiting polyene formation and giving very good initial colour. It was demonstrated that F6 formed a complex with the zinc stearate at room temperature to give a chelate in which the zinc ion is tetracoordinated. Because the costabiliser is able to co-ordinate readily to zinc stearate, this leads to good initial colour, but a more rapid evolution of HCl ('short-term' costabilisation). When the -C=O substituent in the 3-position was replaced by a '-C=N-alkyl' (F6d), or a '-C=N-phenyl' (F6c) group, the behaviour was changed markedly. FTIR and HCl evolution showed that F6d was unstable at 180 deg. C and reacted with HCl evolved from the degraded PVC, decomposing into a basic gas and a structure similar to F6. F6d being more basic formed a complex with the Lewis acid ZnCI 2 instead of zinc stearate. F6c did not interact with the ZnCl 2 or ZnSt 2 , despite the fact that it has an extra nitrogen atom. The reason for this is that the π orbital system of the N-substituted phenyl ring in the 3-position in the pyrrolidine ring is conjugated with the C=N double bond. DHA also interacted with the zinc stearate, but this interaction was significant only at higher temperatures, i.e. after heating to processing temperatures. The

  13. Lab-scale preparations of Candida albicans and dual Candida albicans-Candida glabrata biofilms on the surface of medical-grade polyvinyl chloride (PVC) perfusion tube using a modified gravity-supported free-flow biofilm incubator (GS-FFBI).

    Science.gov (United States)

    Shao, Jing; Lu, KeQiao; Tian, Ge; Cui, YanYan; Yan, YuanYuan; Wang, TianMing; Zhang, XinLong; Wang, ChangZhong

    2015-02-01

    The assembly of a man-made gravity-supported free-flow biofilm incubator (GS-FFBI) was described, which was composed of a gas cushion injector and four incubators. The GS-FFBI had the characteristics of (i) a bottom-up flow direction, and (ii) lab-scale biofilm preparation without the use of a multichannel pump. Two opportunistic fungal strains, namely Candida albicans and Candida glabrata, were employed to incubate C. albicans and dual C. albicans-C. glabrata biofilms on the surface of medical-grade polyvinyl chloride perfusion tube. In terms of the results from {2, 3-bis (2-methoxy-4-nitro-5-sulfo-phenyl)-2H-tetrazolium-5-carboxanilide} (XTT) assay, dry weight measurement, colony-forming unit counting, susceptibility test, and scanning electron microscopy, it was demonstrated that GS-FFBI could form both stable single and dual Candida biofilms with no significant variations among the four incubators or the three daily incubations within 21h, and could operate for at least 96h smoothly with no contamination of stock medium. The results also indicated, for the first time, that C. albicans and C. glabrata might be co-existent competitively and symbiotically in the dual biofilms with flowing media. GS-FFBI would be a useful device to study in vitro morphological and physiological features of microbial biofilms in the medical settings. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. RESISTENCIA MECÁNICA EVALUADA EN EL ENSAYO MARSHALL DE MEZCLAS DENSAS EN CALIENTE ELABORADAS CON ASFALTOS MODIFICADOS CON DESECHOS DE POLICLORURO DE VINILO (PVC, POLIETILENO DE ALTA DENSIDAD (PEAD Y POLIESTIRENO (PS MECHANICAL RESISTANCE OF HOT THICK MIXTURES MADE WITH ASPHALT MODIFIED WITH POLYVINYL CHLORIDE, POLYCLORURE (PVC WASTES, HIGH DENSITY POLYETHYLENE (PEAD, AND POLYSTYRENE (PS EVALUATED IN MARSHALL ASSAY

    Directory of Open Access Journals (Sweden)

    Hugo Alexánder Rondón Quintana

    2007-07-01

    Full Text Available El presente trabajo buscó evaluar en laboratorio el cambio en la resistencia mecánica que experimentan mezclas asfálticas densas en caliente cuando se adicionan, por vía húmeda, al cemento asfáltico aditivos poliméricos producto de desechos industriales del tipo plastómero (policloruro de vinilo, polietileno de alta densidad y poliestireno. Para tal fin se empleó el ensayo Marshall. De los resultados obtenidos se concluye que la resistencia mecánica de mezclas asfálticas modificadas con desechos del tipo plastómero es mayor en comparación con las convencionales (mezclas que emplean asfaltos sin ningún aditivo.The main objective of this research Project was to evaluate in a laboratory the change in mechanical strength that dense hot asphalt mixtures go through when waste polymeric additives of plastomeric type (polyvinyl chloride, high density polyethylene and polystyrene are added to asphalt cement, by 'wet way'. This change was evaluated using Marshall Test. The general conclusion of the experimental results was that modified hot asphalt mixtures present better mechanical behavior than conventional mixtures (mixtures which use asphalt without additives.

  15. Peripheral nerve conduits: technology update

    Science.gov (United States)

    Arslantunali, D; Dursun, T; Yucel, D; Hasirci, N; Hasirci, V

    2014-01-01

    Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS) and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers) and designs (tubular, fibrous, and matrix type) are being presented. PMID:25489251

  16. The corrosion effect on the conduit systems

    International Nuclear Information System (INIS)

    Laaidi, Naouar; Belattar, Sougratti

    2009-01-01

    The conduits in the buildings require a regular and permanent control, in order to avoid the risks of deterioration caused by the corrosion or the escape of water. In this work, we present a thermal nondestructive testing method of concrete structures containing water conduits, based on numerical modeling in three dimensions. The goal is to study the detectability of these conduits in different situations and to give a thermal characterization of the rust behaviour in the steel conduits. (author)

  17. Chloride Test

    Science.gov (United States)

    ... metabolic acidosis ) or when a person hyperventilates (causing respiratory alkalosis ). A decreased level of blood chloride (called hypochloremia) ... disease , emphysema or other chronic lung diseases (causing respiratory ... metabolic alkalosis). An increased level of urine chloride can indicate ...

  18. Comparative scanning electron microscope study of the degradation of a plasticized polyvinyl chloride waterproofing membrane in different conditions; Estudio comparativo con microscopio electrónico de barrido de la degradación de una lámina impermeable de cloruro de polivinilo plastificado en diferentes condiciones

    Energy Technology Data Exchange (ETDEWEB)

    Pedrosa, A.; Del Río, M.

    2017-07-01

    This paper discusses the analysis of several samples of a plasticized polyvinyl chloride (PVC-P) waterproofing membrane. The samples were extracted from different areas of the same flat roof, which was in service for over 12 years. An original sample of an identical PVC-P membrane that was not installed on the roof was also analyzed. The analysis of the materials was carried out using a scanning electron microscope (SEM). An elemental analysis of every sample was also performed by energy dispersive X-ray spectroscopy (EDS). Micrographs and the elemental composition of the samples were compared with the data obtained in the analysis of the original sample. The results show dehydrochlorination of the polymer in two of the samples studied and great deterioration that was not visible to the naked eye in the sample that was totally exposed to the weather. [Spanish] Este estudio discute el análisis de varias muestras de una membrana impermeable de cloruro de polivinilo plastificado (PVC-P). Las muestras fueron extraídas de diferentes áreas de la misma cubierta plana, que estuvo en servicio durante más de 12 años. Una muestra original de idéntica membrana de PVC-P que no estuvo instalada en la cubierta fue también analizada. El análisis de los materiales se llevó a cabo utilizando un microscopio electrónico de barrido (MEB). Además se realizó un análisis elemental sobre cada una de las muestras mediante espectroscopía de dispersión de energía de rayos X (EDS). Las micrografías, y la composición elemental de las muestras, se comparan con los datos obtenidos en el análisis de la muestra original. Los resultados muestran deshidrocloración del polímero en dos de las muestras estudiadas, y un gran deterioro de la muestra totalmente expuesta a la intemperie, que no era visible a simple vista.

  19. Preparação e caracterização reológica de nanocompósitos de poli(cloreto de vinila: plastisol com nano-argila Preparation and rheological characterization of nanocomposites of poly(vinyl chloride: paste with nano-clay

    Directory of Open Access Journals (Sweden)

    Paola P. S. de B. Bettio

    2012-01-01

    Full Text Available Neste trabalho foi estudada a influência da adição de nano-argila nas propriedades reológicas de suspensões de plastisol de poli(cloreto de vinila. Foram utilizados dois tipos de nano-argila, montmorilonita sódica e a organicamente modificada com sal quaternário de amônio, contemplando a avaliação tanto do método de inchamento da argila, quanto da influência da concentração. A nano-argila, na concentração de 2,5, 5, e 10 pcr, foi previamente inchada em plastificante, sob ação de cisalhamento e temperatura. Três tipos de plastificantes foram utilizados, diisobutil ftalato, diisononil ftalato e éster poliglicólico. Experimentos sem o inchamento prévio da argila também foram realizados para validação de sua influência. O plastisol foi obtido com a mistura da nano-argila com o PVC, plastificante diisononil ftalato e demais aditivos, em misturador planetário. A análise dos dados com método estatístico propiciou afirmar que tanto o tipo de argila quanto sua concentração foram determinantes na elevação da viscosidade da pasta, não tendo sido comprovada eficácia do inchamento prévio da argila.The influence from adding nanoclay on the properties of a poly(vinyl chloride plastisol microsuspension was studied. Two types of nanoclay were used, namely sodium montmorillonite and organophilic modified with quaternary ammonium salt, with both the method of clay swelling and clay concentration. Nanoclays at concentrations of 2.5, 5 and 10 phr, were previously swollen in the plasticizer under shear and temperature. Three plasticizers were used, viz. diisobutyl phthalate, diisononyl phthalate and ester polyglycolic. The plastisol was obtained by mixing the nanoclay with PVC, plasticizer diisononyl phthalate and other additives in a planetary mixer. Data analysis was performed with a statistical method, which allowed us to verify that the type of clay and its concentration affect the plastisol viscosity. The clay swelling method

  20. Post-irradiation stability of polyvinyl chloride at sterilizing doses

    International Nuclear Information System (INIS)

    Naimian, F.; Katbab, A.A.; Nazokdast, H.

    1994-01-01

    Post-irradiation stability of plasticized PVC irradiated by 60 Co gamma ray at sterilizing doses has been studied. Effects of irradiation upon chemical structure, mechanical properties and rheological behaviour of samples contained different amounts of Di(2-ethylhexyl)phthalate as plasticizer have been investigated. Formation of conjugated double bonds, carbonyl and hydroxyl groups have been followed by UV and FTIR spectrometers up to 6 months after irradiation. FTIR spectra of irradiated samples showed no significant changes in carbonyl and hydroxyl groups even 6 months after irradiation. However, changes in UV-visible spectra was observed for the irradiated samples up to 6 months post-irradiation. This has been attributed to the formation of polyenes which leads to the discoloration of this polymer. Despite a certain degree of discoloration, it appears that the mechanical properties of PVC are not affected by irradiation at sterilizing doses. No change in the melt viscosity of the irradiated PVC samples with post-irradiation was observed, which is inconsistent with the IR results. (author)

  1. Isolation of polyvinyl chloride degrading bacterial strains from ...

    African Journals Online (AJOL)

    acer

    2012-04-17

    Apr 17, 2012 ... container was stored in laboratory at room temperature. Commercially obtained plastic .... un-reacted Ba(OH)2 in the sample was treated with 0.05 N HCI control, containing .... It did not ferment lactose, galactose, mannose ...

  2. Radiation-induced oxidative degradation of poly(vinyl chloride)

    International Nuclear Information System (INIS)

    Hegazy, E.S.A.; Seguchi, T.; Machi, S.

    1981-01-01

    Gas evolution and oxygen consumption in the γ-irradiation of PVC were studied. The gas evolution and the oxidative degradation are retarded by the presence of plasticizers and stabilizers. The G(HCl) and G(H 2 ) are 8 and 0.24 for the irradiation of pure PVC under vacuum and 0.02 and 0.14 for that of plasticized PVC, respectively. Gas evolution increases in the presence of oxygen, specially for the pure PVC. The G(-O 2 ) values for the pure and plasticized PVC are 30 and 12, respectively. The dependence of gas evolution and oxygen consumption on the oxygen pressure is more pronounced for the plasticized PVC than pure PVC because the oxygen diffusion is controlled

  3. CONTECH(R) A-2000 polyvinyl chloride (PVC) plastic pipe.

    Science.gov (United States)

    2015-03-01

    Determine the effectiveness and long-term durability of the Contech A-2000 PVC pipe : in an irrigation application. This type of pipe may prove to be a viable alternative to : reinforced concrete pipe (RCP).

  4. Charging transient in polyvinyl formal

    Indian Academy of Sciences (India)

    Unknown

    401–406. © Indian Academy of Sciences. 401. Charging transient in polyvinyl formal. P K KHARE*, P L JAIN† and R K PANDEY‡. Department of Postgraduate Studies & Research in Physics & Electronics, Rani Durgavati University,. Jabalpur 482 001, India. †Department of Physics, Government PG College, Damoh 470 ...

  5. Peripheral nerve conduits: technology update

    Directory of Open Access Journals (Sweden)

    Arslantunali D

    2014-12-01

    Full Text Available D Arslantunali,1–3,* T Dursun,1,2,* D Yucel,1,4,5 N Hasirci,1,2,6 V Hasirci,1,2,7 1BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU, Ankara, Turkey; 2Department of Biotechnology, METU, Ankara, Turkey; 3Department of Bioengineering, Gumushane University, Gumushane, Turkey; 4Faculty of Engineering, Department of Medical Engineering, Acibadem University, Istanbul, Turkey; 5School of Medicine, Department of Histology and Embryology, Acibadem University, Istanbul, Turkey; 6Department of Chemistry, Faculty of Arts and Sciences, METU, Ankara, Turkey; 7Department of Biological Sciences, Faculty of Arts and Sciences, METU, Ankara, Turkey *These authors have contributed equally to this work Abstract: Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers and designs (tubular, fibrous, and matrix type are being presented. Keywords: peripheral nerve injury, natural biomaterials, synthetic biomaterials

  6. Conduit for regeneration of biological material

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a conduit comprising a first material, having 1) a through-going hole, 2) fibers aligned along the long-axis in the through-going hole, each fiber having a diameter in the range 200-2000 nm. The conduit is preferably for regeneration of biological material, even...

  7. 47 CFR 32.2441 - Conduit systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Conduit systems. 32.2441 Section 32.2441 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2441 Conduit systems. (a...

  8. Caracterização mecânica e térmica de compósitos de poli (cloreto de vinila reforçados com fibras de sisal Mechanical and thermal characterization of the polyvinyl chloride-sisal fibers composites

    Directory of Open Access Journals (Sweden)

    Gilson S. Martins

    2004-12-01

    Full Text Available Compósitos de PVC, plastificados com diferentes sistemas de plastificação e reforçados com fibras de sisal, foram processados em moinho de dois rolos. A influência do tipo e teor do plastificante, do comprimento e do teor das fibras nas propriedades dos compósitos obtidos foi estudada. Dois tipos de plastificantes foram usados, um líquido (do tipo poliéster e um sólido permanente (copolímero etileno/ acetato de vinila/ monóxido de carbono. As fibras usadas foram previamente lavadas com água a 80 °C por uma hora. Os compósitos, com fibras curtas aleatoriamente distribuídas, foram caracterizados através de ensaio mecânico de resistência à tração, microscopia eletrônica de varredura (MEV, e análises térmicas de calorimetria exploratória diferencial (DSC e análise por termogravimetria (TG. O comprimento ótimo de fibra obtido para os compósitos foi de 6 mm. O uso do plastificante sólido mostrou-se viável e promoveu uma maior molhabilidade da fibra pela matriz nos compósitos, principalmente para teores acima de 40 pcr. As análises térmicas mostraram que a substituição do plastificante líquido pelo plastificante sólido não afetou a estabilidade térmica das matrizes e dos compósitos.Composites consisting of flexible polyvinyl chloride (PVC, plasticized with two different types of plasticizers and reinforced with sisal fibers, were processed on a two-roll mixing mill. Two plasticizers were used, a liquid plasticizer (polyester and a permanent solid plasticizer (ethylene/ vinyl acetate/ carbon monoxide copolymer - Elvaloy® , to form two kinds of polymeric matrices. For each one of these matrices, the influence of plasticizers type, plasticizers content, size and quantity of sisal fibers in the composite properties has been studied. The fibers were washed with water at 80 °C during one hour. The composites with randomly distributed short fibers were characterized by mechanical analysis, scanning electron microscopy

  9. Tile drainage as karst: Conduit flow and diffuse flow in a tile-drained watershed

    Science.gov (United States)

    Schilling, K.E.; Helmers, M.

    2008-01-01

    The similarity of tiled-drained watersheds to karst drainage basins can be used to improve understanding of watershed-scale nutrient losses from subsurface tile drainage networks. In this study, short-term variations in discharge and chemistry were examined from a tile outlet collecting subsurface tile flow from a 963 ha agricultural watershed. Study objectives were to apply analytical techniques from karst springs to tile discharge to evaluate water sources and estimate the loads of agricultural pollutants discharged from the tile with conduit, intermediate and diffuse flow regimes. A two-member mixing model using nitrate, chloride and specific conductance was used to distinguish rainwater versus groundwater inputs. Results indicated that groundwater comprised 75% of the discharge for a three-day storm period and rainwater was primarily concentrated during the hydrograph peak. A contrasting pattern of solute concentrations and export loads was observed in tile flow. During base flow periods, tile flow consisted of diffuse flow from groundwater sources and contained elevated levels of nitrate, chloride and specific conductance. During storm events, suspended solids and pollutants adhered to soil surfaces (phosphorus, ammonium and organic nitrogen) were concentrated and discharged during the rapid, conduit flow portion of the hydrograph. During a three-day period, conduit flow occurred for 5.6% of the time but accounted for 16.5% of the total flow. Nitrate and chloride were delivered primarily with diffuse flow (more than 70%), whereas 80-94% of total suspended sediment, phosphorus and ammonium were exported with conduit and intermediate flow regimes. Understanding the water sources contributing to tile drainage and the manner by which pollutant discharge occurs from these systems (conduit, intermediate or diffuse flow) may be useful for designing, implementing and evaluating non-point source reduction strategies in tile-drained landscapes. ?? 2007 Elsevier B.V. All

  10. Bentall Operation with Valved Homograft Conduit

    Science.gov (United States)

    Choudhary, Shiv K.; Talwar, Sachin; Kumar, A. Sampath

    2000-01-01

    Lesions of the ascending aorta associated with aortic valve disease are usually treated by implanting a prosthetic valved conduit (Bentall procedure). In this report, we present our experience in which a valved homograft conduit was used for the procedure. Six patients underwent a Bentall procedure with the use of a cryopreserved valved homograft conduit. Two of the patients had annuloaortic ectasia, 2 had Marfan syndrome, and 1 had an atherosclerotic aneurysm of the aorta. One patient had severe aortic stenosis due to a bicuspid aortic valve, along with an aneurysm and localized dissection of the ascending aorta. In all of the patients, the aortic annulus was substantially dilated, with accompanying moderate-to-severe aortic regurgitation. A standard procedure was performed with moderate hypothermia, cardiopulmonary bypass, and aortic and bicaval cannulation. The ascending aorta and the aortic valve were replaced with a cryopreserved valved homograft conduit (aortic in 5 patients and pulmonary in 1). The native coronary ostia were anastomosed directly to the homograft. Echocardiography, which was performed intraoperatively, before discharge from the hospital, and at follow-up visits (1 to 36 months), revealed good valve function without dilatation of the homograft conduits. There was 1 late death due to Aspergillus fumigatus endocarditis, 6 months postoperatively. In 1 patient, magnetic resonance imaging performed at 24 months revealed normal caliber of the homograft conduit. We conclude that the Bentall procedure can be performed, safely and with excellent results, using cryopreserved homograft conduits. PMID:11198310

  11. Conduit enlargement in an eogenetic karst aquifer

    Science.gov (United States)

    Moore, Paul J.; Martin, Jonathan B.; Screaton, Elizabeth J.; Neuhoff, Philip S.

    2010-11-01

    SummaryMost concepts of conduit development have focused on telogenetic karst aquifers, where low matrix permeability focuses flow and dissolution along joints, fractures, and bedding planes. However, conduits also exist in eogenetic karst aquifers, despite high matrix permeability which accounts for a significant component of flow. This study investigates dissolution within a 6-km long conduit system in the eogenetic Upper Floridan aquifer of north-central Florida that begins with a continuous source of allogenic recharge at the Santa Fe River Sink and discharges from a first-magnitude spring at the Santa Fe River Rise. Three sources of water to the conduit include the allogenic recharge, diffuse recharge through epikarst, and mineralized water upwelling from depth. Results of sampling and inverse modeling using PHREEQC suggest that dissolution within the conduit is episodic, occurring only during 30% of 16 sampling times between March 2003 and April 2007. During low flow conditions, carbonate saturated water flows from the matrix to the conduit, restricting contact between undersaturated allogenic water with the conduit wall. When gradients reverse during high flow conditions, undersaturated allogenic recharge enters the matrix. During these limited periods, estimates of dissolution within the conduit suggest wall retreat averages about 4 × 10 -6 m/day, in agreement with upper estimates of maximum wall retreat for telogenetic karst. Because dissolution is episodic, time-averaged dissolution rates in the sink-rise system results in a wall retreat rate of about 7 × 10 -7 m/day, which is at the lower end of wall retreat for telogenetic karst. Because of the high permeability matrix, conduits in eogenetic karst thus enlarge not just at the walls of fractures or pre-existing conduits such as those in telogenetic karst, but also may produce a friable halo surrounding the conduits that may be removed by additional mechanical processes. These observations stress the

  12. Stochastic simulation of karst conduit networks

    Science.gov (United States)

    Pardo-Igúzquiza, Eulogio; Dowd, Peter A.; Xu, Chaoshui; Durán-Valsero, Juan José

    2012-01-01

    Karst aquifers have very high spatial heterogeneity. Essentially, they comprise a system of pipes (i.e., the network of conduits) superimposed on rock porosity and on a network of stratigraphic surfaces and fractures. This heterogeneity strongly influences the hydraulic behavior of the karst and it must be reproduced in any realistic numerical model of the karst system that is used as input to flow and transport modeling. However, the directly observed karst conduits are only a small part of the complete karst conduit system and knowledge of the complete conduit geometry and topology remains spatially limited and uncertain. Thus, there is a special interest in the stochastic simulation of networks of conduits that can be combined with fracture and rock porosity models to provide a realistic numerical model of the karst system. Furthermore, the simulated model may be of interest per se and other uses could be envisaged. The purpose of this paper is to present an efficient method for conditional and non-conditional stochastic simulation of karst conduit networks. The method comprises two stages: generation of conduit geometry and generation of topology. The approach adopted is a combination of a resampling method for generating conduit geometries from templates and a modified diffusion-limited aggregation method for generating the network topology. The authors show that the 3D karst conduit networks generated by the proposed method are statistically similar to observed karst conduit networks or to a hypothesized network model. The statistical similarity is in the sense of reproducing the tortuosity index of conduits, the fractal dimension of the network, the direction rose of directions, the Z-histogram and Ripley's K-function of the bifurcation points (which differs from a random allocation of those bifurcation points). The proposed method (1) is very flexible, (2) incorporates any experimental data (conditioning information) and (3) can easily be modified when

  13. Polyvinyl butyral films containing leuco-malachite green as low-dose dosimeters

    International Nuclear Information System (INIS)

    Hoang Hoa Mai; Solomon, H.M.; Taguchi, M.; Kojima, T.

    2008-01-01

    Thin films containing leuco-malachite green (LMG) dye in polyvinyl butyral (PVB) have been developed for dose measurements of a few hundreds Gy level. The film shows significant color change in the visible range, and the sensitivity of the film to absorbed dose was enhanced by addition of chloride-containing compounds, such as chloral hydrate or 2,2,2-trichloroethanol. The film is suitable as dosimeters for dose measurements, e.g. in food irradiation and environmental protection

  14. Pumped Storage and Potential Hydropower from Conduits

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-02-25

    Th is Congressional Report, Pumped Storage Hydropower and Potential Hydropower from Conduits, addresses the technical flexibility that existing pumped storage facilities can provide to support intermittent renewable energy generation. This study considered potential upgrades or retrofit of these facilities, the technical potential of existing and new pumped storage facilities to provide grid reliability benefits, and the range of conduit hydropower opportunities available in the United States.

  15. Polyvinyl alcohol hydrogels for iontohporesis

    Science.gov (United States)

    Bera, Prasanta; Alam, Asif Ali; Arora, Neha; Tibarewala, Dewaki Nandan; Basak, Piyali

    2013-06-01

    Transdermal therapeutic systems propound controlled release of active ingredients through the skin into the systemic circulation in a predictive manner. Drugs administered through these systems escape first-pass metabolism and maintain a steady state scenario similar to a continuous intravenous infusion for up to several days. The iontophoresis deal with the systemic delivery of the bioactive agents (drug) by applying an electric current. It is basically an injection without the needle. The iontophoretic system requires a gel-based matrix to accommodate the bioactive agent. Hydrogels have been used by many investigators in controlled-release drug delivery systems because of their good tissue compatibility and easy manipulation of swelling level and, thereby, solute permeability. In this work we have prepared polyvinyl alcohol (PVA) hydrogel. We have cross linked polyvinyl alcohol chemically with Glutaraldehyde with different wt%. FTIR study reveals the chemical changes during cross linking. Swelling in water, is done to have an idea about drug loading and drug release from the membrane. After drug loading to the hydrogels, we have studied the drug release property of the hydrogels using salicylic acid as a model drug.

  16. Conduit Stability and Collapse in Explosive Volcanic Eruptions: Coupling Conduit Flow and Failure Models

    Science.gov (United States)

    Mullet, B.; Segall, P.

    2017-12-01

    Explosive volcanic eruptions can exhibit abrupt changes in physical behavior. In the most extreme cases, high rates of mass discharge are interspaced by dramatic drops in activity and periods of quiescence. Simple models predict exponential decay in magma chamber pressure, leading to a gradual tapering of eruptive flux. Abrupt changes in eruptive flux therefore indicate that relief of chamber pressure cannot be the only control of the evolution of such eruptions. We present a simplified physics-based model of conduit flow during an explosive volcanic eruption that attempts to predict stress-induced conduit collapse linked to co-eruptive pressure loss. The model couples a simple two phase (gas-melt) 1-D conduit solution of the continuity and momentum equations with a Mohr-Coulomb failure condition for the conduit wall rock. First order models of volatile exsolution (i.e. phase mass transfer) and fragmentation are incorporated. The interphase interaction force changes dramatically between flow regimes, so smoothing of this force is critical for realistic results. Reductions in the interphase force lead to significant relative phase velocities, highlighting the deficiency of homogenous flow models. Lateral gas loss through conduit walls is incorporated using a membrane-diffusion model with depth dependent wall rock permeability. Rapid eruptive flux results in a decrease of chamber and conduit pressure, which leads to a critical deviatoric stress condition at the conduit wall. Analogous stress distributions have been analyzed for wellbores, where much work has been directed at determining conditions that lead to wellbore failure using Mohr-Coulomb failure theory. We extend this framework to cylindrical volcanic conduits, where large deviatoric stresses can develop co-eruptively leading to multiple distinct failure regimes depending on principal stress orientations. These failure regimes are categorized and possible implications for conduit flow are discussed, including

  17. Colloidal titration of aqueous zirconium solutions with poly(vinyl sulfate) by potentiometric endpoint detection using a toluidine blue selective electrode.

    Science.gov (United States)

    Sakurada, Osamu; Kato, Yasutake; Kito, Noriyoshi; Kameyama, Keiichi; Hattori, Toshiaki; Hashiba, Minoru

    2004-02-01

    Zirconium oxy-salts were hydrolyzed to form positively charged polymer or cluster species in acidic solutions. The zirconium hydrolyzed polymer was found to react with a negatively charged polyelectrolyte, such as poly(vinyl sulfate), and to form a stoichiometric polyion complex. Thus, colloidal titration with poly(vinyl sulfate) was applied to measure the zirconium concentration in an acidic solution by using a Toluidine Blue selective plasticized poly(vinyl chloride) membrane electrode as a potentiometric end-point detecting device. The determination could be performed with 1% of the relative standard deviation. The colloidal titration stoichiometry at pH < or = 2 was one mol of zirconium per equivalent mol of poly(vinyl sulfate).

  18. Extreme loads seismic testing of conduit systems

    International Nuclear Information System (INIS)

    Howard, G.E.; Ibanez, P.; Harrison, S.; Shi, Z.T.

    1991-01-01

    Rigid steel conduit (thin-wall tubes with threaded connections) containing electrical cabling are a common feature in nuclear power plants. Conduit systems are in many cases classified in U.S.A. practice as Seismic Category I structures. this paper summarizes results and others aspects of a dynamic test program conducted to investigate conduit systems seismic performance under three-axis excitation for designs representative at a nuclear power plant sited near Ft. Worth, Texas (a moderate seismic zone), with a Safe Shutdown Earthquake (SSE) of 0.12 g. Test specimens where subjected to postulated seismic events, including excitation well in excess of Safe Shutdown Earthquake events typical for U.S.A. nuclear power stations. A total of 18 conduit systems of 9-meter nominal lengths were shake table mounted and subjected to a variety of tests. None of the specimens suffered loss of load capacity when subjected to a site-enveloping Safe Shutdown Earthquake (SSE). Clamp/attachment hardware failures only began to occur when earthquake input motion was scaled upward to minimum values of 2.3-4.6 times site enveloping SSE response spectra. Tensile and/or shear failure of clamp attachment bolts or studs was the failure mode in all case in which failure was induced. (author)

  19. Chemical modification of poly(vinyl alcohol): evaluation of hydrophilic/lipophilic balance

    International Nuclear Information System (INIS)

    Aranha, Isabele B.; Lucas, Elizabete F.

    2001-01-01

    Poly(vinyl alcohol) terpolymers have been obtained by reaction of partially hydrolized poly(vinyl alcohol) with different acid chlorides. The objective is the preparation of polymers with slight differences in their hydrophilic/lipophilic balance and in the interfacial activities of their solutions. The chemical modifications were characterized by means of 1 H NMR and the polymer properties were evaluated in terms of changes in solubility and surface tension. By chemical modification, polymers with low percentage of hydrophobic group were obtained. The water-soluble polymers obtained did not have the surface tension of their solutions altered. The solubility of the modified polymers decreased markedly, even with low contents of hydrophobic groups. (author)

  20. Drill pipes and casings utilizing multi-conduit tubulars

    Energy Technology Data Exchange (ETDEWEB)

    Curlett, H.B.

    1989-01-24

    A seal adapted for use with a multi-conduit well tubular, or the like, is described which consists of: a plate with fluid passages, each passage corresponding to an opening of a conduit of the multiconduit tubular, and a groove on the plate around each passage; and elastomer means partially embeddable into each groove for sealing each conduit of a tubular to a corresponding conduit of another similar tubular.

  1. Method of modifying a vinyl chloride resin by utilizing radiation cross-linking polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Kagiya, T; Fujimoto, T; Hosoi, F; Tsuneta, K; Atogawa, M

    1970-08-26

    The polyvinyl chloride is improved in its mechanical, thermal and chemical properties, with particular advantages gained in dimensional stability at temperatures higher than the plasticizing temperature. The process comprises irradiating a vinyl chloride resin with ionizing radiations in the presence of a vinyl acetate monomer. In this process, the irradiation of vinyl acetate effects cross-linking and the polymerization of the monomer simultaneously. The vinyl chloride resin may be a copolymer along with another monomer, a polyvinyl chloride derivative, a graft polymer of polyvinyl chloride, a mixture of vinyl chloride with another resin and a graft copolymer of vinyl chloride on another resin in any form. The addition of the vinyl acetate monomer to the vinyl chloride is not limited to any particular procedure. The vinyl acetate monomer may be added to the polyvinyl chloride in a quantity ranging from a trace to 200% by weight. The radiation dose may be 10/sup 2/ to 10/sup 9/, but preferably 10/sup 3/ roentgen. In one example, 36 parts by weight of market available vinyl acetate monomer immersed in 100 parts by weight of hard vinyl tube were placed in a stainless reacting vessel. After the replacement of inner air with nitrogen, the vessel was exposed to ..gamma.. beams of 4.8 x 10 roentgen from a Co-60 source. After dipping the exposed samples in boiled tetrahydrofuran for 48 hours, the insoluble substance in the samjle was 78.9% by weight. In addition, after heating at 180/sup 0/C for 30 minutes, the sample did not show any deformation.

  2. Inclusion polymerization of vinyl chloride monomer in deoxycholic acid host via γ-ray irradiation

    International Nuclear Information System (INIS)

    Chirachanchai, S.; Kumkrong, A.; Ishida, Hatsuo

    2000-01-01

    Inclusion polymerization of vinyl chloride monomer (VCM) was studied in the system of 3α, 12α -dihydroxy-5β-cholan-24-oic acid (deoxycholic acid, DCA). DCA-VCM inclusion compound system was originally prepared by guest intercalation technique in DCA guest free crystal. The inclusion polymerization of DCA-VCM by γ-irradiation at total dose 2 Mrad, gives a syndiotactic rich polyvinyl chloride (PVC) as can be confirmed by FT-IR and FT-NMR. (author)

  3. Inclusion polymerization of vinyl chloride monomer in deoxycholic acid host via {gamma}-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chirachanchai, S.; Kumkrong, A. [The Petroleum and Petrochemical College, Chulalongkorn University, Bangkok (Thailand); Ishida, Hatsuo [Department of Macromolecular Science, Case Western Reserve University, Cleveland, OH (United States)

    2000-03-01

    Inclusion polymerization of vinyl chloride monomer (VCM) was studied in the system of 3{alpha}, 12{alpha} -dihydroxy-5{beta}-cholan-24-oic acid (deoxycholic acid, DCA). DCA-VCM inclusion compound system was originally prepared by guest intercalation technique in DCA guest free crystal. The inclusion polymerization of DCA-VCM by {gamma}-irradiation at total dose 2 Mrad, gives a syndiotactic rich polyvinyl chloride (PVC) as can be confirmed by FT-IR and FT-NMR. (author)

  4. Suitability of Polyvinyl Waste Powder as Partial Replacement for ...

    African Journals Online (AJOL)

    B Up to 50% by weight of cement was replaced with PWP at interval of 10%. The parameters investigated are: the chemical composition of polyvinyl waste powder (PWP) and the setting times of cement-polyvinyl paste. Also investigated in concrete containing polyvinyl powder were: workability, density, compressive strength ...

  5. 21 CFR 177.1670 - Polyvinyl alcohol film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyvinyl alcohol film. 177.1670 Section 177.1670... Components of Single and Repeated Use Food Contact Surfaces § 177.1670 Polyvinyl alcohol film. Polyvinyl alcohol film may be safely used in contact with food of the types identified in § 176.170(c) of this...

  6. 76 FR 13982 - Antidumping Duty Order: Polyvinyl Alcohol From Taiwan

    Science.gov (United States)

    2011-03-15

    ...: Polyvinyl Alcohol From Taiwan AGENCY: Import Administration, International Trade Administration, Department... on polyvinyl alcohol (PVA) from Taiwan. DATES: Effective Date: March 15, 2011. FOR FURTHER... from Taiwan. See Polyvinyl Alcohol From Taiwan: Final Determination of Sales at Less Than Fair Value...

  7. 76 FR 13660 - Polyvinyl Alcohol From Taiwan

    Science.gov (United States)

    2011-03-14

    ... Taiwan Determination On the basis of the record \\1\\ developed in the subject investigation, the United... Act of 1930 (19 U.S.C. 1673d(b)) (the Act), that an industry in the United States is materially injured by reason of imports from Taiwan of polyvinyl alcohol, provided for under subheading 3905.30.00 of...

  8. Electric current arising from unpolarized polyvinyl formal

    Indian Academy of Sciences (India)

    Unknown

    An appreciable electric current is observed in a system consisting of a polyvinyl formal (PVF) film in a sandwich ... Electric current; open circuit voltage; water activated phenomenon; plasticization effect. 1. Introduction ... either the trapping parameters or the distribution of the ..... For this reason contact potential drop between.

  9. Polyvinyl alcohol biodegradation under denitrifying conditions

    Czech Academy of Sciences Publication Activity Database

    Marušincová, H.; Husárová, L.; Růžička, J.; Ingr, M.; Navrátil, Václav; Buňková, L.; Koutný, M.

    2013-01-01

    Roč. 84, October (2013), s. 21-28 ISSN 0964-8305 Grant - others:GA ČR(CZ) GAP108/10/0200 Institutional support: RVO:61388963 Keywords : polyvinyl alcohol * biodegradation * denitrification * waste-water treatment * anaerobic * Steroidobacter Subject RIV: EI - Biotechnology ; Bionics Impact factor: 2.235, year: 2013

  10. Optimization of Design of Steam Turbine Exhaust Conduits

    Directory of Open Access Journals (Sweden)

    A. S. Goldin

    2014-01-01

    Full Text Available Improving effectiveness turbine was and remains a key issue for today. In order to improve the efficiency of the turbine is necessary to reduce losses in the steam turbine exhaust conduit.This paper presents the design optimization exhaust conduit steam turbine K-27-2.9 produced by JSC «KTW» at the design stage. The aims of optimizing the design were: decreasing hydraulic resistance of the conduit, reduction of non-uniformity of the flow at the outlet of the conduit, equalizing steam flow ahead of the condenser tube bundle.The conduit models were made and flows in it were simulated in environment of the Solid Works and its application COSMOS Flo Works.As the initial conduit model was selected exhaust conduit of turbine PT-25/34-3.4 produced by JSC «KTW». Was obtained by the calculated velocity field at the outlet of the conduit. The analysis of the calculation results revealed the necessity of changes to the initial design of the conduit. The changes were accompanied by calculating currents flow in the conduit, and assessed the impact of design changes on the nature of the course. Further transformation of the construction of the conduit was held on the results of these calculations. Construction changes are not touched by the outer geometry of the conduit, and were introduced to meet technological.According to calculation results, conclusions were drawn and selected three versions of the conduit.Given are the research results for the initial conduit model and modified design versions. In order to evaluate the flow degree of irregularity the momentum factor (Bussinesku factor for outlet crosssection of the selected conduit design version. Analysis of the research results made it possible to determine optimum design of the exhaust conduit.Introducing the suggested alterations in the conduit design will result in improvement of heat exchange in the condenser, an increase in reliability of the tube bundle operation, a decrease in noise and

  11. SQUG cable tray and conduit evaluation procedure

    International Nuclear Information System (INIS)

    Smith, P.D.; Eder, S.J.; Conoscente, J.P.

    1990-01-01

    Cable tray and conduit systems for electrical cables are a common feature and industrial facilities. They have an excellent performance history in past strong earthquake, even though they are rarely designed for earthquakes. Considerable data have been gathered on their performance in earthquakes and in shake table testing. The data have been used to develop a procedure for the verification of the seismic adequacy of cable tray and conduit systems in operating nuclear plants. The procedure is discussed in this paper. It will result in substantial savings, such as reduced engineering effort, fewer modifications of existing hardware, and simpler documentation, relative to alternate procedures like dynamic analysis of shake table testing. The procedure ensures safety-function in a unique manner since the methodology used to develop it (1) is based on a large body of historical data and (2) uses a relative approach of ensuring that nuclear plant systems will perform at least as well as systems that performed well in past earthquakes. (orig.)

  12. LOAD ON BURIED PRESSURE CONDUITS WITH REFERENCE TO ...

    African Journals Online (AJOL)

    width of conduit or trench; the shearing forces on the plane between the backfill and adjacent earth; for embankment condition, the amounL of relative settlement between the backfill and adjacent earth; the rigidity of the conduit support under embankment loading. Table 3. Selected values of c'' for use in Eq. 8. Sand and.

  13. Water Flow in Karst Aquifer Considering Dynamically Variable Saturation Conduit

    Science.gov (United States)

    Tan, Chaoqun; Hu, Bill X.

    2017-04-01

    The karst system is generally conceptualized as dual-porosity system, which is characterized by low conductivity and high storage continuum matrix and high conductivity and quick flow conduit networks. And so far, a common numerical model for simulating flow in karst aquifer is MODFLOW2005-CFP, which is released by USGS in 2008. However, the steady-state approach for conduit flow in CFP is physically impractical when simulating very dynamic hydraulics with variable saturation conduit. So, we adopt the method proposed by Reimann et al. (2011) to improve current model, in which Saint-Venant equations are used to model the flow in conduit. Considering the actual background that the conduit is very big and varies along flow path and the Dirichlet boundary varies with rainfall in our study area in Southwest China, we further investigate the influence of conduit diameter and outflow boundary on numerical model. And we also analyze the hydraulic process in multi-precipitation events. We find that the numerical model here corresponds well with CFP for saturated conduit, and it could depict the interaction between matrix and conduit during very dynamic hydraulics pretty well compare with CFP.

  14. How to quantify conduits in wood?

    Science.gov (United States)

    Scholz, Alexander; Klepsch, Matthias; Karimi, Zohreh; Jansen, Steven

    2013-01-01

    Vessels and tracheids represent the most important xylem cells with respect to long distance water transport in plants. Wood anatomical studies frequently provide several quantitative details of these cells, such as vessel diameter, vessel density, vessel element length, and tracheid length, while important information on the three dimensional structure of the hydraulic network is not considered. This paper aims to provide an overview of various techniques, although there is no standard protocol to quantify conduits due to high anatomical variation and a wide range of techniques available. Despite recent progress in image analysis programs and automated methods for measuring cell dimensions, density, and spatial distribution, various characters remain time-consuming and tedious. Quantification of vessels and tracheids is not only important to better understand functional adaptations of tracheary elements to environment parameters, but will also be essential for linking wood anatomy with other fields such as wood development, xylem physiology, palaeobotany, and dendrochronology.

  15. Magma wagging and whirling in volcanic conduits

    Science.gov (United States)

    Liao, Yang; Bercovici, David; Jellinek, Mark

    2018-02-01

    Seismic tremor characterized by 0.5-7 Hz ground oscillations commonly occur before and during eruptions at silicic volcanoes with widely ranging vent geometries and edifice structures. The ubiquitous characteristics of this tremor imply that its causes are potentially common to silicic volcanoes. Here we revisit and extend to three dimensions the magma-wagging model for tremor (Jellinek and Bercovici, 2011; Bercovici et al., 2013), wherein a stiff magma column rising in a vertical conduit oscillates against a surrounding foamy annulus of bubbly magma, giving rise to tremor. While prior studies were restricted to two-dimensional lateral oscillations, here we explore three-dimensional motion and additional modes of oscillations. In the absence of viscous damping, the magma column undergoes 'whirling' motion: the center of each horizontal section of the column traces an elliptical trajectory. In the presence of viscous effect we identify new 'coiling' and 'uncoiling' column bending shapes with relatively higher and comparable rates of dissipation to the original two-dimensional magma wagging model. We also calculate the seismic P-wave response of the crustal material around the volcanic conduit to the new whirling motions and propose seismic diagnostics for different wagging patterns using the time-lag between seismic stations. We test our model by analyzing pre-eruptive seismic data from the 2009 eruption of Redoubt Volcano. In addition to suggesting that the occurrence of elliptical whirling motion more than 1 week before the eruption, our analysis of seismic time-lags also implies that the 2009 eruption was accompanied by qualitative changes in the magma wagging behavior including fluctuations in eccentricity and a reversal in the direction of elliptical whirling motion when the eruption was immediately impending.

  16. Chloride test - blood

    Science.gov (United States)

    Serum chloride test ... A greater-than-normal level of chloride is called hyperchloremia. It may be due to: Carbonic anhydrase inhibitors (used to treat glaucoma) Diarrhea Metabolic acidosis Respiratory alkalosis (compensated) Renal ...

  17. Chloride in diet

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002417.htm Chloride in diet To use the sharing features on this page, please enable JavaScript. Chloride is found in many chemicals and other substances ...

  18. Mercuric chloride poisoning

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002474.htm Mercuric chloride poisoning To use the sharing features on this page, please enable JavaScript. Mercuric chloride is a very poisonous form of mercury. It ...

  19. Reverse Saphenous Conduit Flap in 19 Dogs and 1 Cat.

    Science.gov (United States)

    Cavalcanti, Jacqueline V J; Barry, Sabrina L; Lanz, Otto I; Barnes, Katherine; Coutin, Julia V

    2018-05-14

    The purpose of this retrospective study was to report the outcomes of 19 dogs and 1 cat undergoing reverse saphenous conduit flap between 1999 and 2016. Reverse saphenous conduit flap was used to treat traumatic wounds and wounds resulting from tumor excision in the hind limb; the majority of cases had medial shearing injuries. All animals had complete flap survival. In five animals (20%), minor donor site dehiscence occurred, which did not require surgery. Other postoperative complications included signs of severe venous congestion in one dog. Reverse saphenous conduit flap is a useful technique to repair skin defects of the distal hind limb.

  20. Complex compound polyvinyl alcohol-titanic acid/titanium dioxide

    Science.gov (United States)

    Prosanov, I. Yu.

    2013-02-01

    A complex compound polyvinyl alcohol-titanic acid has been produced and investigated by means of IR and Raman spectroscopy, X-ray diffraction, and synchronous thermal analysis. It is claimed that it represents an interpolymeric complex of polyvinyl alcohol and hydrated titanium oxide.

  1. suitability of polyvinyl waste powder as partial replacement

    African Journals Online (AJOL)

    eobe

    as partial replacement of cement in the production o. PWP at interval ... conducted to assess the suitability of polyvinyl waste p polyvinyl waste p .... pose a serious environmental threat because of the fact that they ... served as the control. 2.2.3.

  2. Biological conduit small gap sleeve bridging method for peripheral nerve injury: regeneration law of nerve fibers in the conduit

    Directory of Open Access Journals (Sweden)

    Pei-xun Zhang

    2015-01-01

    Full Text Available The clinical effects of 2-mm small gap sleeve bridging of the biological conduit to repair peripheral nerve injury are better than in the traditional epineurium suture, so it is possible to replace the epineurium suture in the treatment of peripheral nerve injury. This study sought to identify the regeneration law of nerve fibers in the biological conduit. A nerve regeneration chamber was constructed in models of sciatic nerve injury using 2-mm small gap sleeve bridging of a biodegradable biological conduit. The results showed that the biological conduit had good histocompatibility. Tissue and cell apoptosis in the conduit apparently lessened, and regenerating nerve fibers were common. The degeneration regeneration law of Schwann cells and axons in the conduit was quite different from that in traditional epineurium suture. During the prime period for nerve fiber regeneration (2-8 weeks, the number of Schwann cells and nerve fibers was higher in both proximal and distal ends, and the effects of the small gap sleeve bridging method were better than those of the traditional epineurium suture. The above results provide an objective and reliable theoretical basis for the clinical application of the biological conduit small gap sleeve bridging method to repair peripheral nerve injury.

  3. Inkjet-printed Polyvinyl Alcohol Multilayers.

    Science.gov (United States)

    Salaoru, Iulia; Zhou, Zuoxin; Morris, Peter; Gibbons, Gregory J

    2017-05-11

    Inkjet printing is a modern method for polymer processing, and in this work, we demonstrate that this technology is capable of producing polyvinyl alcohol (PVOH) multilayer structures. A polyvinyl alcohol aqueous solution was formulated. The intrinsic properties of the ink, such as surface tension, viscosity, pH, and time stability, were investigated. The PVOH-based ink was a neutral solution (pH 6.7) with a surface tension of 39.3 mN/m and a viscosity of 7.5 cP. The ink displayed pseudoplastic (non-Newtonian shear thinning) behavior at low shear rates, and overall, it demonstrated good time stability. The wettability of the ink on different substrates was investigated, and glass was identified as the most suitable substrate in this particular case. A proprietary 3D inkjet printer was employed to manufacture polymer multilayer structures. The morphology, surface profile, and thickness uniformity of inkjet-printed multilayers were evaluated via optical microscopy.

  4. 26 CFR 1.7701(l)-1 - Conduit financing arrangements.

    Science.gov (United States)

    2010-04-01

    ... determines that such recharacterization is appropriate to prevent avoidance of any tax imposed by title 26 of...) INCOME TAX (CONTINUED) INCOME TAXES General Actuarial Valuations § 1.7701(l)-1 Conduit financing...

  5. Artificial urinary conduit construction using tissue engineering methods.

    Science.gov (United States)

    Kloskowski, Tomasz; Pokrywczyńska, Marta; Drewa, Tomasz

    2015-01-01

    Incontinent urinary diversion using an ileal conduit is the most popular method used by urologists after bladder cystectomy resulting from muscle invasive bladder cancer. The use of gastrointestinal tissue is related to a series of complications with the necessity of surgical procedure extension which increases the time of surgery. Regenerative medicine together with tissue engineering techniques gives hope for artificial urinary conduit construction de novo without affecting the ileum. In this review we analyzed history of urinary diversion together with current attempts in urinary conduit construction using tissue engineering methods. Based on literature and our own experience we presented future perspectives related to the artificial urinary conduit construction. A small number of papers in the field of tissue engineered urinary conduit construction indicates that this topic requires more attention. Three main factors can be distinguished to resolve this topic: proper scaffold construction along with proper regeneration of both the urothelium and smooth muscle layers. Artificial urinary conduit has a great chance to become the first commercially available product in urology constructed by regenerative medicine methods.

  6. Experimental investigations on potassium permanganate doped polyvinyl alcohol - polyvinyl pyrrolidone blend

    Science.gov (United States)

    Veena, G.; Lobo, Blaise

    2018-04-01

    Potassium permanganate (KMnO4) doped polyvinyl alcohol (PVA) - polyvinyl pyrrolidone (PVP) blend films were prepared by solution casting technique, in the doping range varying from 0.01 wt % up to 4.70 wt %. The microstructural changes caused by doping, and the modified properties of these films were studied using Atomic Force Microscope (AFM) and temperature dependent direct current (DC) electrical measurements. Temperature variation of electrical resistivity was found to obey Arrhenius relation, from which activation energy was determined. The study was supported by AFM scans, which showed an increase in surface roughness and the presence of spike-like structures, due to interaction of dopant with the polymeric blend. Differential Scanning Calorimetry (DSC) scans revealed two stages of degradation in KMnO4 doped PVA - PVP blend films.

  7. Chloride ingress prediction

    DEFF Research Database (Denmark)

    Frederiksen, Jens Mejer; Geiker, Mette Rica

    2008-01-01

    Prediction of chloride ingress into concrete is an important part of durability design of reinforced concrete structures exposed to chloride containing environment. This paper presents experimentally based design parameters for Portland cement concretes with and without silica fume and fly ash...... in marine atmospheric and submersed South Scandinavian environment. The design parameters are based on sequential measurements of 86 chloride profiles taken over ten years from 13 different types of concrete. The design parameters provide the input for an analytical model for chloride profiles as function...... of depth and time, when both the surface chloride concentration and the diffusion coefficient are allowed to vary in time. The model is presented in a companion paper....

  8. Polyvinyl alcohol/starch composite nanofibers by bubble electrospinning

    Directory of Open Access Journals (Sweden)

    Liu Zhi

    2014-01-01

    Full Text Available Bubble electrospinning exhibits profound prospect of industrialization of macro/ nano materials. Starch is the most abundant and inexpensive biopolymer. With the drawbacks of poor strength, water resistibility, thermal stability and processability of pure starch, some biodegradable synthetic polymers such as poly (lactic acid, polyvinyl alcohol were composited to electrospinning. To the best of our knowledge, composite nanofibers of polyvinyl alcohol/starch from bubble electrospinning have never been investigated. In the present study, nanofibers of polyvinyl alcohol/starch were prepared from bubble electrospinning. The processability and the morphology were affected by the weight ratio of polyvinyl alcohol and starchy. The rheological studies were in agreement with the spinnability of the electrospinning solutions.

  9. Graphene oxide - Polyvinyl alcohol nanocomposite based electrode material for supercapacitors

    Science.gov (United States)

    Pawar, Pranav Bhagwan; Shukla, Shobha; Saxena, Sumit

    2016-07-01

    Supercapacitors are high capacitive energy storage devices and find applications where rapid bursts of power are required. Thus materials offering high specific capacitance are of fundamental interest in development of these electrochemical devices. Graphene oxide based nanocomposites are mechanically robust and have interesting electronic properties. These form potential electrode materials efficient for charge storage in supercapacitors. In this perspective, we investigate low cost graphene oxide based nanocomposites as electrode material for supercapacitor. Nanocomposites of graphene oxide and polyvinyl alcohol were synthesized in solution phase by integrating graphene oxide as filler in polyvinyl alcohol matrix. Structural and optical characterizations suggest the formation of graphene oxide and polyvinyl alcohol nanocomposites. These nanocomposites were found to have high specific capacitance, were cyclable, ecofriendly and economical. Our studies suggest that nanocomposites prepared by adding 0.5% wt/wt of graphene oxide in polyvinyl alcohol can be used an efficient electrode material for supercapacitors.

  10. The effectiveness of polyethylene glycol (PEG) and polyvinyl ...

    African Journals Online (AJOL)

    mahlos

    2012-05-29

    May 29, 2012 ... Key words: Acetone, tannin, polyethylene glycol (PEG), polyvinyl polypyrrolidone (PVPP). ... hydrolysable tannins may occur in the same plant. ..... Rev. Food Sci. Nutr., 38: 421-464. Cornell. (2000). Tannins: Chemical analysis.

  11. Rheology and structure of aqueous bentonite–polyvinyl alcohol ...

    Indian Academy of Sciences (India)

    Keywords. Bentonite–polyvinyl alcohol dispersions; rheology; zeta potential; particle size analysis; SEM; FTIR studies. 1. .... sity and interception of the linear portion of the curve ..... applications for decolourizing or moisture absorption purpose.

  12. In Vitro Study of Directly Bioprinted Perfusable Vasculature Conduits.

    Science.gov (United States)

    Zhang, Yahui; Yu, Yin; Akkouch, Adil; Dababneh, Amer; Dolati, Farzaneh; Ozbolat, Ibrahim T

    2015-01-01

    The ability to create three dimensional (3D) thick tissues is still a major tissue engineering challenge. It requires the development of a suitable vascular supply for an efficient media exchange. An integrated vasculature network is particularly needed when building thick functional tissues and/or organs with high metabolic activities, such as the heart, liver and pancreas. In this work, human umbilical vein smooth muscle cells (HUVSMCs) were encapsulated in sodium alginate and printed in the form of vasculature conduits using a coaxial deposition system. Detailed investigations were performed to understand the dehydration, swelling and degradation characteristics of printed conduits. In addition, because perfusional, permeable and mechanical properties are unique characteristics of natural blood vessels, for printed conduits these properties were also explored in this work. The results show that cells encapsulated in conduits had good proliferation activities and that their viability increased during prolonged in vitro culture. Deposition of smooth muscle matrix and collagen was observed around the peripheral and luminal surface in long-term cultured cellular vascular conduit through histology studies.

  13. Production of pre-basic potato seed by polyvinyl chloride PVC: articulate gutters hydroponic system

    Directory of Open Access Journals (Sweden)

    Jonny Everson Scherwinski-Pereira

    2009-10-01

    Full Text Available The development of more efficient and productive systems for pre-basic seed potato production would improve the quality of the propagative material used by the potato growers, directly affecting the crop yields. A two-year experiment was carried out to evaluate the potato pre-basic seed production by two types of hydroponic systems (fibrocement tiles and articulated PVC gutters, two cultivars (`Baronesa` and `Eliza` and two types of propagative material (plants coming from in vitro culture and minitubers. The PVC gutters system was highly efficient. When using minitubers, this system reached multiplication rates up to 74 tubers per plant. Minitubers were more productive than in vitro plants, independent of cultivar and hydroponic system utilized.Um experimento realizado por dois anos consecutivos avaliou a produção de sementes pré-básicas de batata por meio de sistemas de cultivo hidropônico. O trabalho testou a combinação de dois sistemas de cultivo (telha de fibrocimento e calhas de PVC articuladas, duas cultivares (Baronesa e Eliza e dois tipos de material propagativo (plântulas oriundas do cultivo in vitro e minitubérculos. O sistema de calhas de PVC foi altamente eficiente. Quando foi utilizado minitubérculos, este sistema alcançou taxas de multiplicação de até 74 tubérculos por planta. De modo geral, o uso de minitubérculos como material propagativo apresentou os melhores resultados de produtividade quando comparada ao material in vitro, independentemente da cultivar e sistemas hidropônicos utilizados.

  14. Enhancement of mechanical properties of poly(vinyl chloride with polymethyl methacrylate-grafted halloysite nanotube

    Directory of Open Access Journals (Sweden)

    2011-07-01

    Full Text Available Halloysite nanotubes(HNTs grafted with Polymethyl methacrylate(PMMA were synthesized via radical polymerization. The properties of PMMA-grafted HNTs were characterized by transmission electron microscopy (TEM, fourier transform infrared spectroscopy (FTIR, thermogravimetric analysis (TGA and X-ray photoelectron spectroscopy (XPS. The results showed that PMMA grafted to the surfaces of HNTs successfully. Then, PVC/PMMA-grafted HNTs nanocomposites were prepared by melt compounding. The morphology, mechanical properties and thermal properties of the nanocomposites were investigated. PMMA-grafted HNTs can effectively improve the toughness, strength and modulus of PVC. The glass transition and thermal decomposition temperatures of PVC phase in PVC/PMMA-grafted HNTs nanocomposites are shifted toward slightly higher temperatures. The grafted HNTs were uniformly dispersed in PVC matrix as revealed by TEM photos. The fracture surfaces of the nanocomposites exhibited plastic deformation feature indicating ductile fracture behaviors. The improvement of toughness of PVC by PMMA-grafted HNTs was attributed to the improved interfacial bonding by grafting and the toughening mechanism was explained according to the cavitation mechanism.

  15. Interaction between plasticized polyvinyl chloride waterproofing membrane and extruded polystyrene board, in the inverted flat roof

    Directory of Open Access Journals (Sweden)

    Pedrosa, A.

    2014-12-01

    Full Text Available The inverted flat roof is a constructive system widely used in flat roof construction. In this constructive solution, the insulation is placed over the waterproofing material as a protection. It is believed that this solution provides a longer life cycle; given the fact that it limits the thermal variation the waterproofing material bears up to the end of its life cycle. Consequently, the result will be providing a longer life to the waterproofing membrane. This constructive solution always incorporates polymers or other materials with a thermoplastic addition in their composition. Some polymers show interactions between them that can affect their integrity, and, at the same time, the bulk of the polymeric materials are incompatible. The extruded polystyrene board is always present in the inverted flat roof, and although it is an unbeatable product for this use, it presents incompatibilities and interactions with other materials, and these can affect their properties and therefore the durability of them.La cubierta plana invertida es un sistema constructivo muy utilizado en las cubiertas planas. En esta solución constructiva, el aislamiento se coloca sobre el material impermeabilizante a modo de protección. Se cree que esta solución proporciona un ciclo de vida más largo; dado que se limita la variación térmica de la impermeabilización hasta el final de su ciclo de vida. En consecuencia, el resultado proporciona una vida más larga a la membrana impermeable. Esta solución constructiva siempre incorpora polímeros u otros materiales con adición termoplástica en su composición. Algunos polímeros muestran interacciones entre ellos que pueden afectar a su integridad, además, la mayor parte de los materiales poliméricos son incompatibles. La plancha de poliestireno extrusionado está siempre presente en la cubierta plana invertida, y aunque es un producto inmejorable para este uso, presenta incompatibilidades e interacciones con otros materiales, y estos pueden afectar a sus propiedades, y por lo tanto a la durabilidad de los mismos.

  16. Study of the simultaneous grafting and heparinisation of poly(vinyl chloride), by gamma radiation

    International Nuclear Information System (INIS)

    Panzarini, Luz Consuelo Gonzalez Alonso

    2003-01-01

    This work had the objective of obtaining the PVC-co-DMAEMA-co-Heparin graft copolymer through process of simultaneous irradiation by γ-radiation coming from a 60 Co source with dose rate ranging between 0,5 and 0,8 kGy h -1 . Grafting parameters were evaluated in function of PVC film swelling time before irradiation, concentration of hydrophilic N,N-dimethylaminoethyl methacrylate (DMAEMA) monomer, radiation doses ranging between zero and 7,0 kGy, concentration of isopropyl alcohol and CUSO 4 as homopolymerization inhibitors varying from 0,02 mol L -1 to 1,0 mol L -1 . Preliminary studies allowed us to establish the concentration of DMAEMA at 30 and 45%. At these two studied concentrations, were observed the highest grafting levels when was utilized 0,02 mol L -1 concentrations of homopolymerization inhibitor. A study of grafting as a function of the dose showed an interdependence between the dose and DMAEMA concentration, where was achieved the highest grafting level at doses of 2,5 kGy and 5,0 kGy for the systems containing 45% and 30% of DMAEMA, respectively. Graft copolymer characterization, accomplished by Fourier transform infrared photoacoustic spectroscopy (FTIR-PAS) evidenced the largest grafting levels for the irradiated samples with 45% of DMAEMA, however heparin presence was only evident on irradiated samples with 30% of DMAEMA. Surface morphological analysis, carried out by scanning electronic microscopy, permitted us to notice that addition of heparin to the reaction medium (0.25% w/v) led to obtaining surfaces less rough than those ones observed in heparin absence, suggesting then a more homogeneous distribution of the graft chains. Evaluation of antithrombogenic properties of the graft copolymers, accomplished 'in vitro' through platelets adhesion test, showed that the increase of surface roughness affects the blood platelet activation mechanisms, leading consequently to a more thrombogenic surface. Analysis by means of electron paramagnetic resonance spectroscopy showed that the kinetical decay of radicals of PVC-co-DMAEMA-coheparin is strongly induced by radicals formed throughout the radiolysis of DMAEMA and PVC. The PVC-co-DMAEMA-co-heparin graft copolymer that presented less thrombogenic surfaces was obtained by means of a simultaneous radiation beam dose of 5,0 KGy on PVC films immersed in aqueous solutions containing DMAEMA (30%), heparin sodium salt (0,25%w/v) and isopropanol (0,02 mol L -1 . (author)

  17. The complex reaction sequence of the thermal and radiolytic degradation of polyvinyl chloride

    International Nuclear Information System (INIS)

    Reichert, W.

    1983-03-01

    The degradation of PVC-foils was been tested by thermal and radiolytic stress in N 2 - and O 2 -atmosphere. Additionally was determined the influence of plasticizers, Fe-, Zn- and Cu-stearates and other additives, which partially are known as stabilizators. Complex mechanisms of degradation are proposed, which were deduced from the HCl-elimination, consumption of oxygen and the shift of the molmass by the scission and crosslinking of main chains both for PVC as combination of PVC with additives. The mechanism corresponds to other known experimental results, too. It was shown, that the radiolytical degradation caused by radicals, which initiate a radical chain mechanism, if the temperature is higher than the glass temperature (Tg). The thermical degradation in a N 2 -atmosphere was explained by an ionic complex mechanism. At the presence of oxygen the ionic mechanism was superimposed by a radical chain mechanism following the oxidation of polyene structures. (author)

  18. 76 FR 30604 - National Emission Standards for Hazardous Air Pollutants for Polyvinyl Chloride and Copolymers...

    Science.gov (United States)

    2011-05-26

    ... a dinner break is scheduled from 5 p.m. until 6:30 p.m. during the hearings. The EPA Web site for... the hearings, such as a translator. The EPA will provide equipment for commenters to show overhead... hearing schedules, including lists of speakers, will be posted on EPA's Web sites http://www.epa.gov/ttn...

  19. Elastic-Plastic Behaviour of Ultrasonic Assisted Compression of Polyvinyl Chloride (PVC) Foam

    Science.gov (United States)

    Muhalim, N. A. D.; Hassan, M. Z.; Daud, Y.

    2018-04-01

    The present study aims to investigate the elastic-plastic behaviour of ultrasonic assisted compression of PVC closed-cell foam. A series of static and ultrasonic compression test of PVC closed-cell foam were conducted at a constant cross head speed of 30 mm/min on dry surface condition. For quasi-static test, specimen was compressed between two rigid platens using universal testing machine. In order to evaluate the specimen behavior under ultrasonic condition, specimen was placed between a specifically design double-slotted block horn and rigid platen. The horn was designed and fabricated prior to the test as a medium to transmit the ultrasonic vibration from the ultrasonic transducer to the working specimen. It was tuned to a frequency of 19.89 kHz in longitudinal mode and provided an average oscillation amplitude at 6 µm on the uppermost surface. Following, the characteristics of stress-strain curves for quasi-static and ultrasonic compression tests were analyzed. It was found that the compressive stress was significantly reduced at the onset of superimposed ultrasonic vibration during plastic deformation.

  20. Migration of additives from poly(vinyl chloride) (PVC) tubes into aqueous media

    DEFF Research Database (Denmark)

    Wang, Qian; Storm, Birgit Kjærside

    2005-01-01

    The stability and migration product of medical PVC tubes plasticized with polyadipates were investigated by ageing in phosphate buffer at pH 1.679 and water at different temperatures. Changes in the PVC tubes were studied by wtaer absorption, weight loss, Fourier infrared spectroscopy (FTIR.......5% and only a small amount of adipic acid migrated when a tube was aged at 37 C in water and phosphate buffer (pH 1.679), and at 70 C in water after 56 days. However, when aged at 70 and 110 C, gradual deactivation of heat stabilizer after 21 days of ageing in buffer solution and separation of plasticizer...... from PVC matrix occurred. When the tube was aged at 110 C, significant degradation of both polyadipates and PVC were observed. Adipic acid and 1,4-butanediol monomers and oligomers of polyadipate were the major migration products from polyadipates in the water ageing solution, while only a relatively...

  1. Itaconamide derivatives as organic stabilizers for poly(vinyl chloride) against photodegradation

    Czech Academy of Sciences Publication Activity Database

    Khalil, A. M.; Rabie, S. T.; Kaprálková, Ludmila; Abd El Ghaffar, M. A.

    2016-01-01

    Roč. 53, č. 2 (2016), s. 96-103 ISSN 1060-1325 Institutional support: RVO:61389013 Keywords : itaconamide * PVC * stabilizer Subject RIV: CD - Macromolecular Chemistry Impact factor: 0.963, year: 2016

  2. 76 FR 29527 - National Emission Standards for Hazardous Air Pollutants for Polyvinyl Chloride and Copolymers...

    Science.gov (United States)

    2011-05-20

    ... LDAR program to detect leaks of VOC into cooling water. For existing sources, we are proposing monthly... strippable VOC in the cooling water or 29 ppmv of total strippable VOC in the stripping gas. When a leak is... the leak. Repairs may be delayed if the concentration of total strippable VOC in the cooling water or...

  3. Comparing Dimensional Accuracy Between a Polyvinyl Chloride Skull and Its Virtually Constructed Counterpart

    Science.gov (United States)

    2015-06-01

    sectioned, viewed in 3-D, drawn upon, treatment planned for direct prosthodontic dental work and even bonded using virtual orthodontic brackets ... orthodontics and oral and maxillofacial surgery, there is a hope that this technology will eliminate the inadequate diagnostic quality of 2-D imaging and...and up to 15 years in most states. This is a big challenge for many dentists, especially orthodontists since most orthodontic patients require

  4. Separation and analysis of low molecular weight plasticizers in poly(vinyl chloride) tubes

    DEFF Research Database (Denmark)

    Wang, Qian; Storm, Birgit Kjærside

    2005-01-01

    ) and thermogravimetric analysis (TGA), as well as by studying the extracted low molecular weight plasticizers by gas chromatography/mass spectroscopy (GC/MS) and GC. It was found that the simple room temperature extraction in chloroform showed the best separation of plasticizers from the PVC matrix. Close results...

  5. Strawberries packaged with Polyvinyl Chloride (PVC film/ Morangos embalados com filme de Ppolicloreto de Vinila (PVC

    Directory of Open Access Journals (Sweden)

    Sergio Ruffo Roberto

    2006-06-01

    Full Text Available Strawberries cv. Dover with approximately 75% of their surface with red color was packaged in disposable polyethylene terephthalate (PET container and sealed with PVC film of 15mm thick. Strawberries without film serves as control. The fruits were stored at 12°C for ten days and there were determined during storage time the titratable acidity, solid soluble and vitamin C contents, color, respiration rate, texture and weight loss. After 6 days the strawberries packaged without film had decayed while the fruits packaged with PVC film were in conditions of consumption and commercialization. After 10 days all fruits were inappropriate to consumption. Packages with PVC film extended the shelf life of strawberries preserving the color characteristic of the product and vitamin C content, reducing the respiration rate and weight loss, characterizing this packaging as being adequate to this kind of product.Foram utilizados morangos cv. Dover com aproximadamente 75% de sua superfície com coloração vermelha e embalados em potes de polietileno tereftalato (PET. No tratamento CONTROLE os morangos foram acondicionados sem filme e no tratamento FILME, as embalagens foram seladas com filme de PVC de 15mm de espessura. As frutas foram armazenadas a 12°C por dez dias e foram determinadas ao longo do tempo acidez titulável, sólidos solúveis, vitamina C, cor, taxa de respiração, textura e perda de massa. Após 6 dias de armazenagem os morangos CONTROLE estavam impróprios para consumo pois apresentavam deterioração visível por bolores enquanto que os embalados com PVC estavam em condições de consumo e comercialização. Após 10 dias todos os morangos estavam impróprios para consumo. A embalagem utilizando filme de PVC aumentou a vida de prateleira de morangos em relação aos sem embalagem pois preservou melhor a coloração característica do produto e teor de vitamina C e reduziu as taxas de respiração e de perda de massa, caracterizando a embalagem como sendo adequada para este tipo de produto.

  6. Ash production by attrition in volcanic conduits and plumes.

    Science.gov (United States)

    Jones, T J; Russell, J K

    2017-07-17

    Tephra deposits result from explosive volcanic eruption and serve as indirect probes into fragmentation processes operating in subsurface volcanic conduits. Primary magmatic fragmentation creates a population of pyroclasts through volatile-driven decompression during conduit ascent. In this study, we explore the role that secondary fragmentation, specifically attrition, has in transforming primary pyroclasts upon transport in volcanic conduits and plumes. We utilize total grain size distributions from a suite of natural and experimentally produced tephra to show that attrition is likely to occur in all explosive volcanic eruptions. Our experimental results indicate that fine ash production and surface area generation is fast (eruption column stability, tephra dispersal, aggregation, volcanic lightening generation, and has concomitant effects on aviation safety and Earth's climate.

  7. Chloride flux in phagocytes.

    Science.gov (United States)

    Wang, Guoshun

    2016-09-01

    Phagocytes, such as neutrophils and macrophages, engulf microbes into phagosomes and launch chemical attacks to kill and degrade them. Such a critical innate immune function necessitates ion participation. Chloride, the most abundant anion in the human body, is an indispensable constituent of the myeloperoxidase (MPO)-H2 O2 -halide system that produces the potent microbicide hypochlorous acid (HOCl). It also serves as a balancing ion to set membrane potentials, optimize cytosolic and phagosomal pH, and regulate phagosomal enzymatic activities. Deficient supply of this anion to or defective attainment of this anion by phagocytes is linked to innate immune defects. However, how phagocytes acquire chloride from their residing environment especially when they are deployed to epithelium-lined lumens, and how chloride is intracellularly transported to phagosomes remain largely unknown. This review article will provide an overview of chloride protein carriers, potential mechanisms for phagocytic chloride preservation and acquisition, intracellular chloride supply to phagosomes for oxidant production, and methods to measure chloride levels in phagocytes and their phagosomes. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Preparation and properties of polyvinyl alcohol microspheres

    International Nuclear Information System (INIS)

    Campbell, J.H.; Grens, J.Z.; Poco, J.F.; Ives, B.H.

    1986-06-01

    Polyvinyl alcohol (PVA) microspheres, having a size range of ∼150- to 250-μm diameter with 1- to 5-μm wall thickness, have been fabricated using a solution droplet technique. The spheres were developed for possible use on the Lawrence Livermore National Laboratory (LLNL) Inertial Confinement Fusion (ICF) Program. PVA, a polymer chosen based on earlier survey work carried out at KMS Fusion, Inc., has good strength, low hydrogen permeability, is optically transparent, and water soluble. The latter property makes it safe and easy to use in our droplet generator system. A unique dual-orifice droplet generator was used to prepare the spheres. The droplet generator operating conditions and the column processing parameters were chosen using results from our 1-D model calculations as a guide. The polymer microsphere model is an extension of the model we developed to support the glass sphere production. After preparation, the spheres were physically characterized for surface quality, sphericity, wall thickness (and uniformity), and size. We also determined the buckling pressure for both uncoated and CH-coated spheres. Radiation stability to beta decay (from tritium) was evaluated by exposing the spheres to a 7-keV electron beam. The results from these and other physical property measurements are presented in this report

  9. Design of barrier coatings on kink-resistant peripheral nerve conduits

    Directory of Open Access Journals (Sweden)

    Basak Acan Clements

    2016-02-01

    Full Text Available Here, we report on the design of braided peripheral nerve conduits with barrier coatings. Braiding of extruded polymer fibers generates nerve conduits with excellent mechanical properties, high flexibility, and significant kink-resistance. However, braiding also results in variable levels of porosity in the conduit wall, which can lead to the infiltration of fibrous tissue into the interior of the conduit. This problem can be controlled by the application of secondary barrier coatings. Using a critical size defect in a rat sciatic nerve model, the importance of controlling the porosity of the nerve conduit walls was explored. Braided conduits without barrier coatings allowed cellular infiltration that limited nerve recovery. Several types of secondary barrier coatings were tested in animal studies, including (1 electrospinning a layer of polymer fibers onto the surface of the conduit and (2 coating the conduit with a cross-linked hyaluronic acid-based hydrogel. Sixteen weeks after implantation, hyaluronic acid-coated conduits had higher axonal density, displayed higher muscle weight, and better electrophysiological signal recovery than uncoated conduits or conduits having an electrospun layer of polymer fibers. This study indicates that braiding is a promising method of fabrication to improve the mechanical properties of peripheral nerve conduits and demonstrates the need to control the porosity of the conduit wall to optimize functional nerve recovery.

  10. Free-boundary models of a meltwater conduit

    KAUST Repository

    Dallaston, Michael C.; Hewitt, Ian J.

    2014-01-01

    © 2014 AIP Publishing LLC. We analyse the cross-sectional evolution of an englacial meltwater conduit that contracts due to inward creep of the surrounding ice and expands due to melting. Making use of theoretical methods from free-boundary problems

  11. Development of a comprehensive inventory management system for underground fiber optic conduits.

    Science.gov (United States)

    2013-03-01

    Major State Departments of Transportation operate and maintain networks of thousands of miles of conduits, many : carrying fiber optic cables that are vital to State communication systems. These conduits are located alongside or : across highways and...

  12. POROSITY OF THE WALL OF A NEUROLAC (R) NERVE CONDUIT HAMPERS NERVE REGENERATION

    NARCIS (Netherlands)

    Meek, Marcel F.; Den Dunnen, Wilfred F. A.

    2009-01-01

    One way to improve nerve regeneration and bridge longer nerve gaps may be the use of semipermeable/porous conduits. With porosity less biomaterial is used for the nerve conduit. We evaluated the short-term effects of porous Neurolac (R) nerve conduits for in vivo peripheral nerve regeneration. In 10

  13. Spectroscopic, thermal, and electrical properties of MgO/ polyvinyl pyrrolidone/ polyvinyl alcohol nanocomposites

    Science.gov (United States)

    Mohammed, Gh.; El Sayed, Adel M.; Morsi, W. M.

    2018-04-01

    In this study, we aimed to control the optical and electrical properties of polyvinyl alcohol (PVA) in order to broaden its industrial and technological applications, which we achieved by blending PVA with polyvinyl pyrrolidone (PVP) and adding sol-gel prepared MgO nanopowder. The blended film and nanocomposite films were prepared using the solution casting technique. X-ray diffraction analyses showed that the crystallite size was ∼18.4 nm for MgO and the highest degree of crystallinity (XC) in the films was about 24.34% at 1.0 wt% MgO. High resolution transmission electron microscopy determined the nanoribbon morphology of MgO. Scanning electron microscopy (SEM) indicated the uniform distribution of the MgO nanoribbons on the surfaces of the PVA/PVP films. SEM and Fourier transform infrared spectroscopy also confirmed the interaction between the blend and MgO fillers. The effects of the additives on the glass transition (Tg) and melting (Tm) temperatures were evaluated by differential thermal analysis and differential scanning calorimetry. The appearance of one melting point confirmed the miscibility of the two polymers. According to ultraviolet-visible-near infrared spectroscopy measurements, the optical properties and optical constants of PVA could be adjusted by the addition of PVP and MgO, where the optical band gap (Eg) determined for PVA increased with the PVP content, whereas it decreased to 4.8 eV as the MgO content increased. The DC conductivity (σdc) of the films increased whereas the activation energy (Ea) decreased after the addition of MgO, possibly because the nanoribbon shape fixed the preferred conducting pathways. In addition, MgO could break the H-bond in sbnd OH groups of the blends to allow the free movement of the molecular chains.

  14. Frictional melting and stick-slip behavior in volcanic conduits

    Science.gov (United States)

    Kendrick, Jackie Evan; Lavallee, Yan; Hirose, Takehiro; di Toro, Giulio; Hornby, Adrian Jakob; Hess, Kai-Uwe; Dingwell, Donald Bruce

    2013-04-01

    Dome-building eruptions have catastrophic potential, with dome collapse leading to devastating pyroclastic flows with almost no precursory warning. During dome growth, the driving forces of the buoyant magma may be superseded by controls along conduit margins; where brittle fracture and sliding can lead to formation of lubricating cataclasite and gouge. Under extreme friction, pseudotachylyte may form at the conduit margin. Understanding the conduit margin processes is vital to understanding the continuation of an eruption and we postulate that pseudotachylyte generation could be the underlying cause of stick-slip motion and associated seismic "drumbeats", which are so commonly observed at dome-building volcanoes. This view is supported by field evidence in the form of pseudotachylytes identified in lava dome products at Soufrière Hills (Montserrat) and Mount St. Helens (USA). Both eruptions were characterised by repetitive, periodic seismicity and lava spine extrusion of highly viscous magma. High velocity rotary shear (HVR) experiments demonstrate the propensity for melting of the andesitic and dacitic material (from Soufrière Hills and Mount St. Helens respectively) at upper conduit stress conditions (HVR experiments which mimic rapid velocity fluctuations in stick-slip behavior demonstrate velocity-weakening behavior of melt, with a tendency for unstable slip. During ascent, magma may slip and undergo melting along the conduit margin. In the process the shear resistance of the slip zone is increased, acting as a viscous brake halting slip (the "stick" of stick-slip motion). Sufficient buoyancy-driven pressures from ascending magma below eventually overcome resistance to produce a rapid slip event (the "slip") along the melt-bearing slip zone, which is temporarily lubricated due to velocity-weakening. New magma below experiences the same slip event more slowly (as the magma decompresses) to produce a viscous brake and the process is repeated. This allows a

  15. Chloride removal from vitrification offgas

    Energy Technology Data Exchange (ETDEWEB)

    Slaathaug, E.J. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-06-01

    This study identified and investigated techniques of selectively purging chlorides from the low-level waste (LLW) vitrification process with the purge stream acceptable for burial on the Hanford Site. Chlorides will be present in high concentration in several individual feeds to the LLW Vitrification Plant. The chlorides are highly volatile in combustion type melters and are readily absorbed by wet scrubbing of the melter offgas. The Tank Waste Remediation System (TWRS) process flow sheets show that the resulting chloride rich scrub solution is recycled back to the melter. The chlorides must be purged from the recycle loop to prevent the buildup of excessively high chloride concentrations.

  16. Chloride removal from vitrification offgas

    International Nuclear Information System (INIS)

    Slaathaug, E.J.

    1995-01-01

    This study identified and investigated techniques of selectively purging chlorides from the low-level waste (LLW) vitrification process with the purge stream acceptable for burial on the Hanford Site. Chlorides will be present in high concentration in several individual feeds to the LLW Vitrification Plant. The chlorides are highly volatile in combustion type melters and are readily absorbed by wet scrubbing of the melter offgas. The Tank Waste Remediation System (TWRS) process flow sheets show that the resulting chloride rich scrub solution is recycled back to the melter. The chlorides must be purged from the recycle loop to prevent the buildup of excessively high chloride concentrations

  17. Biocarbon urinary conduit: laboratory experience and clinical applications.

    Science.gov (United States)

    Kobashi, L I; Raible, D A

    1980-07-01

    A new urinary conduit utilizing pure vitreous carbon has been used successfully in dogs. Pure carbon appears to be inert with respect to urine and urothelium. Lack of urinary salt encrustation on the exposed surface provides a well-functioning urinary conduit for vesical drainage. Twenty-one vesicostomies were performed in dogs. Careful follow-up and histologic studies of removed specimens were done to establish the biocompatibility of pure carbon. All vesicostomies functioned well. A description of the device, protocol, and results of laboratory experimentation are outlined. The surgical procedure is explained in detail. Results encourage the clinical trial of these devices in humans. Indications include patients with neurogenic vesicla dysfunction and those with total urinary incontinence, both of which require permanent indwelling catheters.

  18. Tension layer winding of cable-in-conduit conductor

    International Nuclear Information System (INIS)

    Devernoe, A.; Ciancetta, G.; King, M.; Parizh, M.; Painter, T.; Miller, J.

    1996-01-01

    A 710 mm i.d. by 440 mm long, 6 layer Cable-in-Conduit (CIC) coil was precision tension layer wound with Incoloy 908 jacketed conductor to model winding technology that will be used for the Nb 3 Sn outsert coils of the 45 Tesla Hybrid Magnet Project at the US National High Magnetic Field Laboratory. This paper reports on the set up of a new winding facility with unique capabilities for insulating and winding long length CIC conductor and on special procedures which were developed to wind and support layer to layer transitions and to safely form conductor into and out of the winding. Analytical methods used to predict conduit keystoning, springback and back tensioning requirements before winding are reported in comparison to results obtained during winding and actual winding build-up dimensions on a layer by layer basis in comparison to design requirements

  19. Stability of methadone hydrochloride in 0.9% sodium chloride injection in single-dose plastic containers.

    Science.gov (United States)

    Denson, D D; Crews, J C; Grummich, K W; Stirm, E J; Sue, C A

    1991-03-01

    The stability of methadone hydrochloride in 0.9% sodium chloride injection in flexible polyvinyl chloride containers was studied. Commercially available methadone hydrochloride 20 mg/mL and 25-mL single-dose bags of 0.9% sodium chloride injection were used. Six samples each were prepared at methadone hydrochloride concentrations of 1, 2, and 5 mg/mL. The solutions were stored at room temperature and were not protected from light. Immediately after preparation and after two, three, and four weeks of storage, each of the 18 samples was divided into three aliquots, each of which was analyzed in duplicate for methadone hydrochloride concentration by gas chromatography. There was less than 10% change in methadone hydrochloride concentration in any sample throughout the four-week study period. Methadone hydrochloride at concentrations of 1, 2, and 5 mg/mL prepared in commercially available flexible polyvinyl chloride containers of 0.9% sodium chloride injection and stored at room temperature without deliberate protection from light is stable for at least four weeks.

  20. Erosion of cohesive soil layers above underground conduits

    Directory of Open Access Journals (Sweden)

    Luu Li-Hua

    2017-01-01

    Full Text Available Using a recently developed 2D numerical modelling that combines Discrete Element (DEM and Lattice Boltzmann methods (LBM, we simulate the destabilisation by an hydraulic gradient of a cohesive granular soil clogging the top of an underground conduit. We aim to perform a multi-scale study that relates the grain scale behavior to the macroscopic erosion process. In particular, we study the influence of the flow conditions and the inter-particle contact forces intensity on the erosion kinetic.

  1. Erosion of cohesive soil layers above underground conduits

    Science.gov (United States)

    Luu, Li-Hua; Philippe, Pierre; Noury, Gildas; Perrin, Jérôme; Brivois, Olivier

    2017-06-01

    Using a recently developed 2D numerical modelling that combines Discrete Element (DEM) and Lattice Boltzmann methods (LBM), we simulate the destabilisation by an hydraulic gradient of a cohesive granular soil clogging the top of an underground conduit. We aim to perform a multi-scale study that relates the grain scale behavior to the macroscopic erosion process. In particular, we study the influence of the flow conditions and the inter-particle contact forces intensity on the erosion kinetic.

  2. CIBLAGE D'INFLATION ET CONDUITE DE LA POLITIQUE ...

    African Journals Online (AJOL)

    Administrateur

    de l'amendement de la loi relative à la monnaie et au crédit, l'Algérie a explicitement ... la Banque d'Algérie, très importante pour la conduite de la politique monétaire. ..... matière de contrainte budgétaire entre les secteurs public et privé. En.

  3. Explosive device of conduit using Ti Ni alloy

    Directory of Open Access Journals (Sweden)

    A. Yu. Kolobov

    2014-01-01

    Full Text Available Presently, materials have been developed which are capable at changing temperate to return significant inelastic deformations, exhibit rubber-like elasticity, convert heat into mechanical work, etc. The aggregate of these effects is usually called the shape memory effect.At present a great number of compounds and alloys with a shape memory effect has been known.These are alloys based on titanium nickelide (TiNi, copper-based alloys (Cu-Al, Cu-Sn, Cu-Al-Ni, Cu-Zn-Si, etc., gold and silver (Ag-Cd, Au-Ag-Cd, Au-Cd-Cu, Au-Zn-Cu, etc., manganese (Mn-Cr, Fe-Cu, Mn-Cu-Ni, Mn-Cu-Zr, Mn-Ni, etc., iron (Fe-Mn, Fe-Ni, Fe-Al, etc., and other compounds.The alloys based on titanium nickelide (nitinol are the most widely used.Alloys with shape memory effect find various applications in engineering and medicine, namely connecting devices, actuators, transformable design, multipurpose medical implants, etc.There is a task of breaking fuel conduit during separating the spacecraft from the rocket in space technology.The paper examines the procedure for design calculation of the separating device of conduit with the use of Ti-Ni alloy. This device can be used instead of the pyro-knives.The device contains two semi-rings from Ti-Ni alloy. In the place of break on the conduit an annular radius groove is made.At a temperature of martensite passage the semi-rings undergo deformation and in the strained state are set in the device. With heating to the temperature of the austenitic passage of bushing macro-deformation the energy stored by the nitinol bushing is great enough to break the conduit on the neck.The procedures of design calculation and response time of device are given.

  4. Vinyl Chloride Emulsion Polymerization Reaction: Effect of Various Formulations

    Directory of Open Access Journals (Sweden)

    Seyed Mehrdad Jalilian

    2013-01-01

    Full Text Available A mixture  of  sodium  lauryl  sulfate  (SLS  as  ionic  emulsifer  and  stearyl alcohol as non-ionic emulsifer was employed in a vinyl chloride emulsion polymerization  reaction  to  study  the  infuence  of  various  interactive parameters involved in the reaction system. It was found that the particle size was dependent on the amount and type of emulsifer. The average particle size of polyvinyl chloride was dropped by higher amount of emulsifying agents.  At the gel point, more heat was generated by higher amount of vinyl chloride fed into the reaction system. The molecular weight of the polymer was decreased by increases in reaction temperature while,  it  increased by augmenting  the amount of emulsifer. According to the 13C NMR and FTIR spectroscopic data no defect was detected in the chain structure of synthetic polyvinylchloride product. An optimization of polymerization reaction condition was reached based on ultimate particle size desired for its favorable distribution in plastisols.

  5. Novel drug delivering conduit for peripheral nerve regeneration

    Science.gov (United States)

    Labroo, Pratima; Shea, Jill; Edwards, Kyle; Ho, Scott; Davis, Brett; Sant, Himanshu; Goodwin, Isak; Gale, Bruce; Agarwal, Jay

    2017-12-01

    Objective. This paper describes the design of a novel drug delivery apparatus integrated with a poly lactic-co-glycolic acid (PLGA) based nerve guide conduit for controlled local delivery of nerve growth factor (NGF) and application in peripheral nerve gap injury. Approach. An NGF dosage curve was acquired to determine the minimum in vitro concentration for optimal neurite outgrowth of dorsal root ganglion (DRG) cells; PLGA based drug delivery devices were then designed and tested in vitro and in vivo across 15 mm rat sciatic nerve gap injury model. Main results. The drug delivery nerve guide was able to release NGF for 28 d at concentrations (0.1-10 ng ml-1) that were shown to enhance DRG neurite growth. Furthermore, the released NGF was bioactive and able to enhance DRG neurite growth. Following these tests, optimized NGF-releasing nerve conduits were implanted across 15 mm sciatic nerve gaps in a rat model, where they demonstrated significant myelination and muscle innervation in vivo as compared to empty nerve conduits (p  design process and provides increased versatility for releasing a variety of different growth factors. This innovative device has the potential for broad applicability and allows for easier customization to change the type of drugs and dosage of individual drugs without devising a completely new biomaterial-drug conjugate each time.

  6. Free-boundary models of a meltwater conduit

    KAUST Repository

    Dallaston, Michael C.

    2014-08-01

    © 2014 AIP Publishing LLC. We analyse the cross-sectional evolution of an englacial meltwater conduit that contracts due to inward creep of the surrounding ice and expands due to melting. Making use of theoretical methods from free-boundary problems in Stokes flow and Hele-Shaw squeeze flow we construct an exact solution to the coupled problem of external viscous creep and internal heating, in which we adopt a Newtonian approximation for ice flow and an idealized uniform heat source in the conduit. This problem provides an interesting variant on standard free-boundary problems, coupling different internal and external problems through the kinematic condition at the interface. The boundary in the exact solution takes the form of an ellipse that may contract or expand (depending on the magnitudes of effective pressure and heating rate) around fixed focal points. Linear stability analysis reveals that without the melting this solution is unstable to perturbations in the shape. Melting can stabilize the interface unless the aspect ratio is too small; in that case, instabilities grow largest at the thin ends of the ellipse. The predictions are corroborated with numerical solutions using boundary integral techniques. Finally, a number of extensions to the idealized model are considered, showing that a contracting circular conduit is unstable to all modes of perturbation if melting occurs at a uniform rate around the boundary, or if the ice is modelled as a shear-thinning fluid.

  7. Mechanical cleaning of oil spills in seawater using circular conduits

    Energy Technology Data Exchange (ETDEWEB)

    Shedid, S.; Abou Kassem, J.; Zekri, A. [United Arab Emirates Univ., Al Ain City (United Arab Emirates). Dept. of Chemical and Petroleum Engineering

    2005-10-15

    Treatment of the crude oil pollution in seawater has attracted global attention during the last two decades. This study was undertaken using circular conduits as a mechanical means to clean oil spills in seawater under different conditions of temperature, oil gravity, shaking frequency, conduit diameter, and initial thickness of oil layer. An experimental model was designed and built to achieve the study. It consists of shaking water bath (to represent sea waves) fitted with temperature controller and glass tubes of different inside diameters of 0.3 cm, 0.5 cm, and 0.7 cm. Three crude oils of different oil gravity of 35{sup o}API, 38{sup o}API, and 47{sup o}API were investigated under different shaking frequencies of 20, 40, and 60 stroke/minute with different tube diameters. The results proved that application of mechanical cleaning of oil spills using circular conduits is a practical technique. The cleaning of black oil spills is more efficient than one of volatile oil. Furthermore, the results indicated that the increase of shaking frequency and/or water temperature provide(s) faster cleaning of oil spills while temperature increase recovers the maximum oil. (Author)

  8. Peripheral nerve regeneration with conduits: use of vein tubes.

    Science.gov (United States)

    Sabongi, Rodrigo Guerra; Fernandes, Marcela; Dos Santos, João Baptista Gomes

    2015-04-01

    Treatment of peripheral nerve injuries remains a challenge to modern medicine due to the complexity of the neurobiological nerve regenerating process. There is a greater challenge when the transected nerve ends are not amenable to primary end-to-end tensionless neurorraphy. When facing a segmental nerve defect, great effort has been made to develop an alternative to the autologous nerve graft in order to circumvent morbidity at donor site, such as neuroma formation, scarring and permanent loss of function. Tubolization techniques have been developed to bridge nerve gaps and have been extensively studied in numerous experimental and clinical trials. The use of a conduit intends to act as a vehicle for moderation and modulation of the cellular and molecular ambience for nerve regeneration. Among several conduits, vein tubes were validated for clinical application with improving outcomes over the years. This article aims to address the investigation and treatment of segmental nerve injury and draw the current panorama on the use of vein tubes as an autogenous nerve conduit.

  9. Peripheral nerve regeneration with conduits: use of vein tubes

    Directory of Open Access Journals (Sweden)

    Rodrigo Guerra Sabongi

    2015-01-01

    Full Text Available Treatment of peripheral nerve injuries remains a challenge to modern medicine due to the complexity of the neurobiological nerve regenerating process. There is a greater challenge when the transected nerve ends are not amenable to primary end-to-end tensionless neurorraphy. When facing a segmental nerve defect, great effort has been made to develop an alternative to the autologous nerve graft in order to circumvent morbidity at donor site, such as neuroma formation, scarring and permanent loss of function. Tubolization techniques have been developed to bridge nerve gaps and have been extensively studied in numerous experimental and clinical trials. The use of a conduit intends to act as a vehicle for moderation and modulation of the cellular and molecular ambience for nerve regeneration. Among several conduits, vein tubes were validated for clinical application with improving outcomes over the years. This article aims to address the investigation and treatment of segmental nerve injury and draw the current panorama on the use of vein tubes as an autogenous nerve conduit.

  10. Parastomal hernias after radical cystectomy and ileal conduit diversion

    Directory of Open Access Journals (Sweden)

    Timothy F. Donahue

    2016-07-01

    Full Text Available Parastomal hernia, defined as an “incisional hernia related to an abdominal wall stoma”, is a frequent complication after conduit urinary diversion that can negatively impact quality of life and present a clinically significant problem for many patients. Parastomal hernia (PH rates may be as high as 65% and while many patients are asymptomatic, in some series up to 30% of patients require surgical intervention due to pain, leakage, ostomy appliance problems, urinary obstruction, and rarely bowel obstruction or strangulation. Local tissue repair, stoma relocation, and mesh repairs have been performed to correct PH, however, long-term results have been disappointing with recurrence rates of 30%–76% reported after these techniques. Due to high recurrence rates and the potential morbidity of PH repair, efforts have been made to prevent PH development at the time of the initial surgery. Randomized trials of circumstomal prophylactic mesh placement at the time of colostomy and ileostomy stoma formation have shown significant reductions in PH rates with acceptably low complication profiles. We have placed prophylactic mesh at the time of ileal conduit creation in patients at high risk for PH development and found it to be safe and effective in reducing the PH rates over the short-term. In this review, we describe the clinical and radiographic definitions of PH, the clinical impact and risk factors associated with its development, and the use of prophylactic mesh placement for patients undergoing ileal conduit urinary diversion with the intent of reducing PH rates.

  11. Lithium thionyl chloride battery

    Energy Technology Data Exchange (ETDEWEB)

    Saathoff, D.J.; Venkatasetty, H.V.

    1982-10-19

    The discharge rate and internal conductivity of electrochemical cell including a lithium anode, and a cathode and an electrolyte including LiAlCl4 and SOC2 is improved by the addition of an amount of a mixture containing AlCl3 and butyl pyridinium chloride.

  12. The medical sodium chloride

    International Nuclear Information System (INIS)

    Mirsaidov, U.M.

    2002-01-01

    In the institute was investigated the chemical composition of rock salt of some deposits of Tajikistan and was show the presence in it admixture of ions of Ca 2 + , Mg 2 + a nd SO 2 - a nd absence of heavy metals, ammonium salts, iron, potassium and arsenic. Was elaborated the fundamental instrument-technologic scheme of sodium chloride receiving

  13. Ultraviolet sensing properties of polyvinyl alcohol-coated aluminium ...

    Indian Academy of Sciences (India)

    Undoped and aluminium (Al)-doped zinc oxide (ZnO) nanorods have been synthesized by electrochemical route. The synthesized materials have been characterized by X-ray diffraction, UV–visible spectrometer and scanning electron microscope. The Al-doped ZnO nanorods have been coated with polyvinyl alcohol.

  14. Time-dependent micro-Raman scattering studies of polyvinyl ...

    Indian Academy of Sciences (India)

    2014-02-15

    Feb 15, 2014 ... Micro-Raman scattering; surface plasmons; silver nanoparticles; polyvinyl alcohol. PACS Nos 74.25.nd; ... as well as their characterization. Added .... 3.2 Surface plasmon absorption of thin films of PVA + AgNO3. The surface ...

  15. The study of epoxy polyamide and polyvinyl resins as corrosion ...

    African Journals Online (AJOL)

    The corrosion resistance of two commonly used protective coatings (epoxy polyamide and polyvinyl resins) in the Niger Delta area of Nigeria has been assessed. The coatings on low carbon steel were subjected to varying conditions of pH, temperature and exposure time and the corrosion rates calculated. At a pH of 2, 3, 4, ...

  16. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited

    NARCIS (Netherlands)

    Xia, Wenfeng; Piras, Daniele; Heijblom, Michelle; Steenbergen, Wiendelt; van Leeuwen, Ton G.; Manohar, Srirang

    2011-01-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F-T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where

  17. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited

    NARCIS (Netherlands)

    Xia, W.; Piras, D.; Heijblom, M.; Steenbergen, Wiendelt; van Leeuwen, Ton; Manohar, Srirang

    2011-01-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F–T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where

  18. Preparation and Characterization of Formalated Polyvinyl Alcohol Hydrogel Film

    International Nuclear Information System (INIS)

    Than Than Aye; Nyunt Win; San Myint

    2011-12-01

    A feasible hydrogen film was prepared from polyvinyl alcohol (PVA) sample. The effect of chemical grafting on polyvinyl alcohol film was studied. Polyvinyl alcohol sample was mixed with distilled water and autoclaved at 121C for 60 minutes. An aqueous solution of polyvinyl alcohol was casted into a steel plate and dried for a certain time at room temperature. The obtained PVA film was immersed in formalation bath containing aqueous formaldehyde, sulphuric acid, anhydrous sodium sulphate with a weight ratio of (64:95:300) and 1 liter of distilled water at 60C for various hours. Effect of formalation time was studied varying 6, 12, 24, 36 and 48 hours. Degree of formalation was also evaluated. Physical properties of the hydrogel film such as gel fraction, degree of swelling and mechanical properties such as tensile strength, elongation and hardness were determined before and after formalation of the PVA film. Fourier Transform Infrared Spectroscopic (FTIR) analysis, Thermogravimetric / Differential thermal analysis (DTA / TG) were also studied for characterization. It was found that the appropriate condition for formalation was occured at 24 hours formalation time of with the calculated degree of formalation 65.35% with the determined values (9.04 Mpa) for tensile strength, (241.92%) for elongation, (45.30 Shore D) for hardness, (280.36%) for degree of swelling and (68.32%) for gel fraction.

  19. 75 FR 15726 - Polyvinyl Alcohol From Taiwan; Determination

    Science.gov (United States)

    2010-03-30

    ... an industry in the United States is materially injured by reason of imports from Taiwan of polyvinyl.... industry was materially injured or threatened with material injury by reason of imports of PVA from Taiwan... Alcohol From Taiwan; Determination On the basis of the record \\1\\ developed in the subject investigation...

  20. Radiation-chemical preparation of poly(vinyl alcohol) hydrogels

    International Nuclear Information System (INIS)

    Duflot, Anastasia V.; Kitaeva, Natalia K.; Duflot, Vladimir R.

    2015-01-01

    This work reports the usage of method of radiation-chemical synthesis to prepare cross-linked hydrogels from poly(vinyl alcohol) modified with glycidyl methacrylate. Synthesis kinetics of modified poly(vinyl alcohol) and properties of hydrogels were studied. The gel fraction, swelling, mechanical properties, and water content of the hydrogels were measured. It was found that gel fraction increases with increasing radiation dose, concentration of modified poly(vinyl alcohol), and reaches 60%. It was established by differential scanning calorimetry that a fraction of the “bound” water in hydrogels is 50–70% and independent of gel fraction content. In addition to “bound” and “free” states, water in hydrogels is also present in the intermediate state. - Highlights: • The synthesis and the properties of poly(vinyl alcohol) hydrogels were studied. • PVA was modified by glycidyl methacrylate before gamma cross-linking. • The modification results in decreasing of PVA cross-linking dose by 3 orders lower. • The gel fraction and water content of the hydrogels were measured. • A fraction of the “bound” water in hydrogels is independent of gel fraction content

  1. Potentiometric titration of polyhexamethylene biguanide hydrochloride with potassium poly(vinyl sulfate) solution using a cationic surfactant-selective electrode.

    Science.gov (United States)

    Masadome, Takashi; Yamagishi, Yuichi; Takano, Masaki; Hattori, Toshiaki

    2008-03-01

    A potentiometric titration method using a cationic surfactant as an indicator cation and a plasticized poly(vinyl chloride) membrane electrode sensitive to the cationic surfactant is proposed for the determination of polyhexamethylene biguanide hydrochloride (PHMB-HCl), which is a cationic polyelectrolyte. A sample solution of PHMB-HCl containing an indicator cation (hexadecyltrimethylammonium ion, HTA) was titrated with a standard solution of an anionic polyelectrolyte, potassium poly(vinyl sulfate) (PVSK). The end-point was detected as a sharp potential change due to an abrupt decrease in the concentration of the indicator cation, HTA, which is caused by its association with PVSK. The effects of the concentrations of HTA ion and coexisting electrolytes in the sample solution on the degree of the potential change at the end-point were examined. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant exists in the concentration range from 2.0 x 10(-5) to 4.0 x 10(-4) M in the case that the concentration of HTA is 1.0 x 10(-5) M, and that from 1.0 x 10(-6) to 1.2 x 10(-5) M in the case that the concentration of HTA is 5.0 x 10(-6) M, respectively. The proposed method was applied to the determination of PHMB-HCl in some contact-lens detergents.

  2. Effect of hygroscopic materials on water vapor permeation and dehumidification performance of poly(vinyl alcohol) membranes

    KAUST Repository

    Bui, T. D.

    2017-01-16

    In this study, two hygroscopic materials, inorganic lithium chloride (LiCl) and organic triethylene glycol (TEG) were separately added to poly(vinyl alcohol) (PVA) to form blend membranes for air dehumidification. Water vapor permeation, dehumidification performance and long-term durability of the membranes were studied systematically. Membrane hydrophilicity and water vapor sorbability increased significantly with higher the hygroscopic material contents. Water vapor permeance of the membranes increased with both added hygroscopic material and absorbed water. Water permeation energy varied from positive to negative with higher hygroscopic content. This observation is attributed to a lower diffusion energy and a relatively constant sorption energy when hygroscopic content increases. Comparatively, PVA/TEG has less corrosive problems and is more environmentally friendly than PVA/LiCl. A membrane with PVA/TEG is observed to be highly durable and is suitable for dehumidification applications.

  3. Synthesis and characterization of poly(vinyl alcohol) membranes with quaternary ammonium groups for wound dressing.

    Science.gov (United States)

    Chen, Kuo-Yu; Lin, Yu-Sheng; Yao, Chun-Hsu; Li, Ming-Hsien; Lin, Jui-Che

    2010-01-01

    2-[(acryloyloxy)ethyl]Trimethylammonium chloride (AETMAC) was grafted onto poly(vinyl alcohol) (PVA) using ceric ammonium nitrate (CAN) as a redox initiator. A series of graft co-polymer (PVA-g-PAETMAC) membranes with different contents of AETMAC were prepared with a casting method. The incorporation of AETMAC into PVA chains was confirmed by element analysis and Fourier transform infrared spectroscopy. The effects of grafting on the thermal properties, water take, water vapor transmission rate (WVTR), contact angle, antibacterial activity and cytotoxicity of PVA-g-PAETMAC membranes were investigated. The experiment results showed that PVA-g-PAETMAC membrane has a higher equilibrium swelling ratio, surface hydrophilicity and WVTR than pure PVA membrane. Moreover, the higher the content of AETMAC, the higher were equilibrium swelling ratio, surface hydrophilicity and WVTR. In vitro bacterial adhesion study demonstrated a significantly reduced number of Staphylococcus aureus and Escherichia coli on PVA-g-PAETMAC surfaces when compared to PVA surface. In addition, no significant difference in the in vitro cytotoxicity was observed between PVA and PVA-g-PAETMAC membranes. The presence of quaternary ammonium groups did not reduce L929 cell growth. Therefore, the PVA-g-PAETMAC membranes have the potential for wound-dressing application.

  4. Immobilization of ammonia-oxidizing bacteria by polyvinyl alcohol and sodium alginate.

    Science.gov (United States)

    Dong, Yuwei; Zhang, Yanqiu; Tu, Baojun

    Ammonia-oxidizing bacteria were immobilized by polyvinyl alcohol (PVA) and sodium alginate. The immobilization conditions and ammonia oxidation ability of the immobilized bacteria were investigated. The following immobilization conditions were observed to be optimal: PVA, 12%; sodium alginate, 1.1%; calcium chloride, 1.0%; inoculum concentration, 1.3 immobilized balls/mL of immobilized medium; pH, 10; and temperature, 30°C. The immobilized ammonia-oxidizing bacteria exhibited strong ammonia oxidation ability even after being recycled four times. The ammonia nitrogen removal rate of the immobilized ammonia-oxidizing bacteria reached 90.30% under the optimal immobilization conditions. When compared with ammonia-oxidizing bacteria immobilized by sodium alginate alone, the bacteria immobilized by PVA and sodium alginate were superior with respect to pH resistance, the number of reuses, material cost, heat resistance, and ammonia oxidation ability. Copyright © 2017 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  5. Pseudotachylyte formation in volcanic conduits: Montserrat vs. Mount St. Helens

    Science.gov (United States)

    Kendrick, J. E.; Lavallee, Y.; Petrakova, L.; Ferk, A.; Di Toro, G.; Hess, K.; Ferri, F.; Dingwell, D. B.

    2012-12-01

    Seismogenic fracture and faulting may result in non-equilibrium frictional melting of rock, which upon cooling and recrystallisation forms pseudotachylyte. In volcanic environments, the transition from endogenous to exogenous growth can be attributed to a shift in magma rheology into the brittle regime, and thus the ascent of high-viscosity magma can form discrete shear zones, comparable to tectonic faults, along conduit margins. Pseudotachylytes have, until now, rarely been noted in exogenous volcanic materials and seldom in active volcanic environments. This is despite the simultaneous occurrence of high pressures and differential stresses, which make high-viscosity magmas ideal candidates for the occurrence of frictional melting. Here, we compare the chemical, thermal, magnetic and structural properties of two candidate volcanic pseudotachylytes; one from Soufriere Hills (Montserrat) and one from Mount St. Helens (USA). Additionally, we present data from a set of high-velocity rotary shear experiments on the host materials of these natural pseudotachylytes in which melting was induced after just 10's of centimeters of slip at realistic extrusion velocities (0.4 - 1.6 ms-1) and low normal stresses (0.5-2 MPa). After 1-2 meters of slip a continuous melt layer formed, at which point friction decreased and the fault zone displayed slip-weakening behaviour. For volcanic conduits, this would facilitate temporarily elevated slip rates, or an increase in extrusion rate, and could cause transitions in dome morphology and eruption style. This study demonstrates that shear fracturing in magma or sliding along conduit margins can readily result in frictional melting. The conspicuous absence of pseudotachylytes in active volcanic environments is likely the result of exceptionally high background temperatures which precipitate near-equilibrium melting, thereby obviating one of the characteristic signatures of pseudotachylyte - glassy protomelts formed by selective melting of

  6. Influence of vinyl chloride monomer and vinyl chloride monomer derivatives on hepatic DNA synthesis

    International Nuclear Information System (INIS)

    Brenner, E.A.

    1982-01-01

    Vinyl chloride monomer (VCM) is used extensively in the chemical industry, mainly in the production of polyvinyl chloride. It has recently been found to cause hepatic angiosarcoma. As VCM has also been shown to be mutagenic after metabolic activation the effect of VCM on DNA synthesis was investigated. [ 3 H]Thymidine incorporation into DNA was used to measure the rate of DNA synthesis in regenerating rat liver. A possible direct toxic effect of VCM or its metabolites on liver cell metabolism was examined by two unrelated techniques, viz. the measurement of adenine nucleotide concentrations in regenerating livers and the influence on transmembrane potentials in hepatocytes. The distribution of radioactivity in subcellular fractions following [ 14 C]VCM administration suggested microsomal conversion of VCM to an active form which was selectively retained in the nuclear fraction. Measurement of the activities of thymidine kinase and DNA polymerase in regenerating liver indicated that the induction of these enzymes which normally occurs after partial hepatectomy was not prevented by VCM treatment. Three techniques were used to test the hypothesis that the retardation in DNA synthesis was due to DNA damage: the prophage lambda induction test for DNA damage, autoradiographic detection of unscheduled thymidine incorporation into DNA, and detection of DNA strand breaks in alkaline sucrose gradients. All three provided evidence of DNA damage and led to the development of a novel technique to confirm these findings. This involved centrifugation in neutral sucrose gradients on intact double-stranded DNA contained in hepatocyte nucleoids and showed conclusively that VCM administration causes DNA strand breaks. Subsequent repair of DNA was also assessed by this technique. The site of the VCM/metabolite: DNA reaction was characterized by DNA thermal denaturation and renaturation studies

  7. Geometry and Hydraulics of Englacial Conduits, Storglaciaren, Sweden

    Science.gov (United States)

    Fountain, A. G.; Schlichting, R.; Frodin, S.; Jacobel, R. W.

    2001-12-01

    Englacial conduits are the primary structure responsible for transporting surface water to the base of a glacier, where it supplies the subglacial hydraulic system and, in turn, affects glacier movement. Despite the well-known theoretical descriptions of englacial conduits, little direct evidence exists about their geometry and hydraulics. In July 2001, we initiated a field effort on Storglaciären, Sweden, to intersect englacial conduits by drilling into the glacier using a hot water drill. A companion project (Jacobel et al., this session) attempted to detect the englacial conduits using ground-penetrating radar. In a typical borehole, the water level remained at the surface while drilling through the impermeable ice. Once a connection was made, the water level dropped roughly 10 m and remained low despite continued water pumping. A small video camera was lowered, with attachments, to measure the geometry of the opening, and water flow speed. The water level in the hole provided a piezometric measure of the pressure. We drilled 22 holes at 3 separate locations and 17 (77%) connected englacially, the remaining 5 reached the bed without englacial connection, of which 2 drained at the bed. The geometry of the connections was highly irregular in cross-section with 1-2 cm openings, reminiscent of crevasse-like features rather than circular cross-sections as anticipated from the theoretical literature. Flow behavior was observed by tracking particle motion. The flow was complicated, in part by the inferred tangential intersection between the borehole and structure, and by the observed surging behavior. Flow speeds were low, on the order of 1 cm sec-1. Water level records from 3 different holes over several days exhibited highly correlated variations and large diurnal excursions. In contrast, records from holes drilled to the bed showed little variation. Based on these measurements, our conceptual picture of the englacial system is that of a sluggish flow system

  8. Stability of Dexmedetomidine in 0.9% Sodium Chloride in Two Types of Intravenous Infusion Bags.

    Science.gov (United States)

    Marquis, Kathleen; Hohlfelder, Benjamin; Szumita, Paul M

    2017-01-01

    Dexmedetomidine is a frequently used sedative in the critical care setting. It is commercially available as a 4-mg/mL premixed compound or as 200-mcg/2-mL vials that must be further diluted prior to administration. However, limited data exist regarding the stability of dexmedetomidine admixtures compounded from the 200-mcg/2-mL vials, particularly for durations greater than 48 hours. Therefore, we performed stability testing on compounded dexmedetomidine prepared in two types of intravenous infusion bags for 14 days. Dexmedetomidine is available as 200-mcg/2-mL vials for dilution, 80-mcg/20-mL single-dose vials, and as 200-mcg/50-mL and 400-mcg/100-mL glass bottles. The stability of dexmedetomidine admixtures has previously been tested for 48 hours. The purpose of this analysis was to test the stability of dexmedetomidine admixtures for 14 days. Six dexmedetomidine admixtures of 200 mcg/50 mL were compounded in polyvinyl chloride and non-polyvinyl chloride bags, three of which were stored under refrigeration and three of which were kept at room temperature. High-performance liquid chromatography testing was performed to determine the concentration at Days 1 through 14. Stability was determined by taking the mean concentration of samples taken from each bag. All samples were tested in duplicate. A sample was considered stable if the concentration was greater than 90% of the original concentration. All samples retained over 90% of the drug under their respective storage conditions for the duration of the study. At time 0, the concentration of dexmedetomidine was between 3.99 mcg/mL and 4.01 mcg/mL. On Day 14, the mean concentration was between 95.8% and 98.9%, depending on the bag type and storage condition. The pH remained between 4.7 and 5.8 during the study period as has previously been reported in the literature. Dexmedetomidine admixtures of 200 mcg/50 mL were stable in both polyvinyl chloride bags and non-polyvinyl chloride bags for 14 days under refrigeration

  9. Short-term outcomes after incontinent conduit for gynecologic cancer: comparison of ileal, sigmoid, and transverse colon.

    Science.gov (United States)

    Tabbaa, Zaid M; Janco, Jo Marie T; Mariani, Andrea; Dowdy, Sean C; McGree, Michaela E; Weaver, Amy L; Cliby, William A

    2014-06-01

    The aim of this study is to estimate the overall rates of significant incontinent conduit-related complications and compare rates between conduit types. This was a retrospective review of 166 patients who underwent incontinent urinary diversion from April 1993 through April 2013. Patients were categorized by conduit type-ileal, sigmoid colon, and transverse colon. Significant conduit-related complications were assessed at 30 and 90days after surgery. Significant conduit-related complication was defined as any of the following: ureteral stricture, conduit leak, conduit obstruction, conduit ischemia, ureteral anastomotic leak, stent obstruction requiring intervention via interventional radiology procedure or reoperation, and renal failure. A total of 166 patients underwent formation of an incontinent urinary conduit, most commonly during exenteration for gynecologic malignancy. There were 129 ileal, 11 transverse colon, and 26 sigmoid conduits. The overall significant conduit-related complication rate within 30days was 15.1%. Complication rates for ileal, transverse and sigmoid conduits were 14.7%, 0%, and 23.1%, respectively (Fisher's exact test, p=0.24). By 90days, the Kaplan-Meier estimated rates of significant complications were 21.8% overall, and 22.3%, 0%, and 28.9%, respectively, by conduit type (log-rank test, p=0.19). The most common significant conduit-related complications were conduit or ureteral anastomotic leaks and conduit obstructions. By 1 and 2years following surgery, the Kaplan-Meier estimated overall rate of significant conduit-related complication increased to 26.5% and 30.1%, respectively. Our study suggests that there are multiple appropriate tissue sites for use in incontinent conduit formation, and surgical approach should be individualized. Most significant conduit-related complications occur within 90days after surgery. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Treatment of right ventricle to pulmonary artery conduit stenosis in infants with hypoplastic left heart syndrome.

    Science.gov (United States)

    Münsterer, Andrea; Kasnar-Samprec, Jelena; Hörer, Jürgen; Cleuziou, Julie; Eicken, Andreas; Malcic, Ivan; Lange, Rüdiger; Schreiber, Christian

    2013-09-01

    To determine the incidence of right ventricle-to-pulmonary artery (RV-PA) conduit stenosis after the Norwood I operation in patients with hypoplastic left heart syndrome (HLHS), and to determine whether the treatment strategy of RV-PA conduit stenosis has an influence on interstage and overall survival. Ninety-six patients had a Norwood operation with RV-PA conduit between 2002 and 2011. Details of reoperations/interventions due to conduit obstruction prior to bidirectional superior cavopulmonary anastomosis (BSCPA) were collected. Overall pre-BSCPA mortality was 17%, early mortality after Norwood, 6%. Early angiography was performed in 34 patients due to desaturation at a median of 8 days after the Norwood operation. Fifteen patients (16%) were diagnosed with RV-PA conduit stenosis that required treatment. The location of the conduit stenosis was significantly different in the patients with non-ringed (proximal) and the patients with ring-enforced conduit (distal), P = 0.004. In 6 patients, a surgical revision of the conduit was performed; 3 of them died prior to BSCPA. Another 6 patients had a stent implantation and 3 were treated with balloon dilatation followed by a BSCPA in the subsequent 2 weeks. All patients who were treated interventionally for RV-PA conduit obstruction had a successful BSCPA. Patients who received a surgical RV-PA conduit revision had a significantly higher interstage (P = 0.044) and overall mortality (P = 0.011) than those who received a stent or balloon dilatation of the stenosis followed by an early BSCPA. RV-PA conduit obstruction after Norwood I procedure in patients with HLHS can be safely and effectively treated by stent implantation, balloon dilatation and early BSCPA. Surgical revision of the RV-PA conduit can be reserved for patients in whom an interventional approach fails, and an early BSCPA is not an option.

  11. A novel conduit-based coaptation device for primary nerve repair.

    Science.gov (United States)

    Bamba, Ravinder; Riley, D Colton; Kelm, Nathaniel D; Cardwell, Nancy; Pollins, Alonda C; Afshari, Ashkan; Nguyen, Lyly; Dortch, Richard D; Thayer, Wesley P

    2018-06-01

    Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.

  12. Evidence for Arbovirus Dissemination Conduits from the Mosquito (Diptera: Culicidae) Midgut

    National Research Council Canada - National Science Library

    Romoser, William

    2004-01-01

    .... Experiments using Venezuelan equine encephalitis viral replicon particles, which express the green fluorescent protein gene in cells, indicate the operation of tissue conduits, possibly involving...

  13. Regenerative potential of silk conduits in repair of peripheral nerve injury in adult rats.

    Science.gov (United States)

    Huang, W; Begum, R; Barber, T; Ibba, V; Tee, N C H; Hussain, M; Arastoo, M; Yang, Q; Robson, L G; Lesage, S; Gheysens, T; Skaer, Nicholas J V; Knight, D P; Priestley, J V

    2012-01-01

    Various attempts have been made to develop artificial conduits for nerve repair, but with limited success. We describe here conduits made from Bombyx mori regenerated silk protein, and containing luminal fibres of Spidrex(®), a silk-based biomaterial with properties similar to those of spider silk. Assessment in vitro demonstrated that Spidrex(®) fibres support neurite outgrowth. For evaluation in vivo, silk conduits 10 mm in length and containing 0, 100, 200 or 300 luminal Spidrex(®) fibres, were implanted to bridge an 8 mm gap in the rat sciatic nerve. At 4 weeks, conduits containing 200 luminal Spidrex(®) fibres (PN200) supported 62% and 59% as much axon growth as autologous nerve graft controls at mid-conduit and distal nerve respectively. Furthermore, Spidrex(®) conduits displayed similar Schwann cell support and macrophage response to controls. At 12 weeks, animals implanted with PN200 conduits showed similar numbers of myelinated axons (81%) to controls, similar gastrocnemius muscle innervation, and similar hindpaw stance assessed by Catwalk footprint analysis. Plantar skin innervation was 73% of that of controls. PN200 Spidrex(®) conduits were also effective at bridging longer (11 and 13 mm) gaps. Our results show that Spidrex(®) conduits promote excellent axonal regeneration and function recovery, and may have potential for clinical application. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. 3D-engineering of Cellularized Conduits for Peripheral Nerve Regeneration

    Science.gov (United States)

    Hu, Yu; Wu, Yao; Gou, Zhiyuan; Tao, Jie; Zhang, Jiumeng; Liu, Qianqi; Kang, Tianyi; Jiang, Shu; Huang, Siqing; He, Jiankang; Chen, Shaochen; Du, Yanan; Gou, Maling

    2016-08-01

    Tissue engineered conduits have great promise for bridging peripheral nerve defects by providing physical guiding and biological cues. A flexible method for integrating support cells into a conduit with desired architectures is wanted. Here, a 3D-printing technology is adopted to prepare a bio-conduit with designer structures for peripheral nerve regeneration. This bio-conduit is consisted of a cryopolymerized gelatin methacryloyl (cryoGelMA) gel cellularized with adipose-derived stem cells (ASCs). By modeling using 3D-printed “lock and key” moulds, the cryoGelMA gel is structured into conduits with different geometries, such as the designed multichannel or bifurcating and the personalized structures. The cryoGelMA conduit is degradable and could be completely degraded in 2-4 months in vivo. The cryoGelMA scaffold supports the attachment, proliferation and survival of the seeded ASCs, and up-regulates the expression of their neurotrophic factors mRNA in vitro. After implanted in a rat model, the bio-conduit is capable of supporting the re-innervation across a 10 mm sciatic nerve gap, with results close to that of the autografts in terms of functional and histological assessments. The study describes an indirect 3D-printing technology for fabricating cellularized designer conduits for peripheral nerve regeneration, and could lead to the development of future nerve bio-conduits for clinical use.

  15. Rheology and structure of aqueous bentonite–polyvinyl alcohol ...

    Indian Academy of Sciences (India)

    Abstract. The influence of polymer on flow behaviour of Balikesir, Turkey bentonite dispersions (2%, w/w) was studied for non-ionic polymer, polyvinyl alcohol (PVA). In a range of 3⋅3 × 10–6 – 3⋅3 × 105 mol/l, PVA was added to the bentonite dispersions in different concentrations and its behaviour was observed on ...

  16. Polyvinyl siloxane: novel material for external nasal splinting.

    Science.gov (United States)

    Jayakumar, N K; Rathnaprabhu, V; Ramesh, S; Parameswaran, A

    2016-01-01

    External nasal splinting is performed routinely after nasal bone fracture reductions, osteotomies, and rhinoplasties. Materials commonly used include plaster of Paris (POP), thermoplastic splints, self-adhesive padded aluminium splints, and Orthoplast, among many others. The disadvantages of these materials are described in this paper, and polyvinyl siloxane is recommended as an effective and more readily available alternative material to counter these pitfalls. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Stability of polyvinyl alcohol-coated biochar nanoparticles in brine

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, Christopher, E-mail: cgriffith@utexas.edu; Daigle, Hugh [University of Texas at Austin, Department of Petroleum and Geosystems Engineering (United States)

    2017-01-15

    This paper reports on the dispersion stability of 150 nm polyvinyl alcohol coated biochar nanoparticles in brine water. Biochar is a renewable, carbon based material that is of significant interest for enhanced oil recovery operations primarily due to its wide ranging surface properties, low cost of synthesis, and low environmental toxicity. Nanoparticles used as stabilizing agents for foams (and emulsions) or in nanofluids have emerged as potential alternatives to surfactants for subsurface applications due to their improved stability at reservoir conditions. If, however, the particles are not properly designed, they are susceptible to aggregation because of the high salinity brines typical of oil and gas reservoirs. Attachment of polymers to the nanoparticle surface, through covalent bonds, provides steric stabilization, and is a necessary step. Our results show that as the graft density of polyvinyl alcohol increases, so too does the stability of nanoparticles in brine solutions. A maximum of 34 wt% of 50,000 Da polyvinyl alcohol was grafted to the particle surface, and the size of the particles was reduced from ~3500 nm (no coating) to 350 nm in brine. After 24 h, the particles had a size of ~500 nm, and after 48 h completely aggregated. 100,000 Da PVA coated at 24 wt% on the biochar particles were stable in brine for over 1 month with no change in mean particle size of ~330 nm.

  18. Convection in a volcanic conduit recorded by bubbles

    Science.gov (United States)

    Carey, Rebecca J.; Manga, Michael; Degruyter, Wim; Gonnermann, Helge M.; Swanson, Donald; Houghton, Bruce F.; Orr, Tim R.; Patrick, Matthew R.

    2013-01-01

    Microtextures of juvenile pyroclasts from Kīlauea’s (Hawai‘i) early A.D. 2008 explosive activity record the velocity and depth of convection within the basaltic magma-filled conduit. We use X-ray microtomography (μXRT) to document the spatial distribution of bubbles. We find small bubbles (radii from 5 μm to 70 μm) in a halo surrounding larger millimeter-size bubbles. This suggests that dissolved water was enriched around the larger bubbles—the opposite of what is expected if bubbles grow as water diffuses into the bubble. Such volatile enrichment implies that the volatiles within the large bubbles were redissolving into the melt as they descended into the conduit by the downward motion of convecting magma within the lava lake. The thickness of the small bubble halo is ∼100–150 μm, consistent with water diffusing into the melt on time scales on the order of 103 s. Eruptions, triggered by rockfall, rapidly exposed this magma to lower pressures, and the haloes of melt with re-dissolved water became sufficiently supersaturated to cause nucleation of the population of smaller bubbles. The required supersaturation pressures are consistent with a depth of a few hundred meters and convection velocities of the order of 0.1 m s−1, similar to the circulation velocity observed on the surface of the Halema‘uma‘u lava lake.

  19. Conduit for high temperature transfer of molten semiconductor crystalline material

    Science.gov (United States)

    Fiegl, George (Inventor); Torbet, Walter (Inventor)

    1983-01-01

    A conduit for high temperature transfer of molten semiconductor crystalline material consists of a composite structure incorporating a quartz transfer tube as the innermost member, with an outer thermally insulating layer designed to serve the dual purposes of minimizing heat losses from the quartz tube and maintaining mechanical strength and rigidity of the conduit at the elevated temperatures encountered. The composite structure ensures that the molten semiconductor material only comes in contact with a material (quartz) with which it is compatible, while the outer layer structure reinforces the quartz tube, which becomes somewhat soft at molten semiconductor temperatures. To further aid in preventing cooling of the molten semiconductor, a distributed, electric resistance heater is in contact with the surface of the quartz tube over most of its length. The quartz tube has short end portions which extend through the surface of the semiconductor melt and which are lef bare of the thermal insulation. The heater is designed to provide an increased heat input per unit area in the region adjacent these end portions.

  20. Exploring Ultimate Water Capillary Evaporation in Nanoscale Conduits.

    Science.gov (United States)

    Li, Yinxiao; Alibakhshi, Mohammad Amin; Zhao, Yihong; Duan, Chuanhua

    2017-08-09

    Capillary evaporation in nanoscale conduits is an efficient heat/mass transfer strategy that has been widely utilized by both nature and mankind. Despite its broad impact, the ultimate transport limits of capillary evaporation in nanoscale conduits, governed by the evaporation/condensation kinetics at the liquid-vapor interface, have remained poorly understood. Here we report experimental study of the kinetic limits of water capillary evaporation in two dimensional nanochannels using a novel hybrid channel design. Our results show that the kinetic-limited evaporation fluxes break down the limits predicated by the classical Hertz-Knudsen equation by an order of magnitude, reaching values up to 37.5 mm/s with corresponding heat fluxes up to 8500 W/cm 2 . The measured evaporation flux increases with decreasing channel height and relative humidity but decreases as the channel temperature decreases. Our findings have implications for further understanding evaporation at the nanoscale and developing capillary evaporation-based technologies for both energy- and bio-related applications.

  1. Documentation of a Conduit Flow Process (CFP) for MODFLOW-2005

    Science.gov (United States)

    Shoemaker, W. Barclay; Kuniansky, Eve L.; Birk, Steffen; Bauer, Sebastian; Swain, Eric D.

    2007-01-01

    This report documents the Conduit Flow Process (CFP) for the modular finite-difference ground-water flow model, MODFLOW-2005. The CFP has the ability to simulate turbulent ground-water flow conditions by: (1) coupling the traditional ground-water flow equation with formulations for a discrete network of cylindrical pipes (Mode 1), (2) inserting a high-conductivity flow layer that can switch between laminar and turbulent flow (Mode 2), or (3) simultaneously coupling a discrete pipe network while inserting a high-conductivity flow layer that can switch between laminar and turbulent flow (Mode 3). Conduit flow pipes (Mode 1) may represent dissolution or biological burrowing features in carbonate aquifers, voids in fractured rock, and (or) lava tubes in basaltic aquifers and can be fully or partially saturated under laminar or turbulent flow conditions. Preferential flow layers (Mode 2) may represent: (1) a porous media where turbulent flow is suspected to occur under the observed hydraulic gradients; (2) a single secondary porosity subsurface feature, such as a well-defined laterally extensive underground cave; or (3) a horizontal preferential flow layer consisting of many interconnected voids. In this second case, the input data are effective parameters, such as a very high hydraulic conductivity, representing multiple features. Data preparation is more complex for CFP Mode 1 (CFPM1) than for CFP Mode 2 (CFPM2). Specifically for CFPM1, conduit pipe locations, lengths, diameters, tortuosity, internal roughness, critical Reynolds numbers (NRe), and exchange conductances are required. CFPM1, however, solves the pipe network equations in a matrix that is independent of the porous media equation matrix, which may mitigate numerical instability associated with solution of dual flow components within the same matrix. CFPM2 requires less hydraulic information and knowledge about the specific location and hydraulic properties of conduits, and turbulent flow is approximated by

  2. Contribution of garbage burning to chloride and PM2.5 in Mexico City

    Directory of Open Access Journals (Sweden)

    N. Bei

    2012-09-01

    Full Text Available The contribution of garbage burning (GB emissions to chloride and PM2.5 in the Mexico City Metropolitan Area (MCMA has been investigated for the period of 24 to 29 March during the MILAGRO-2006 campaign using the WRF-CHEM model. When the MCMA 2006 official emission inventory without biomass burning is used in the simulations, the WRF-CHEM model significantly underestimates the observed particulate chloride in the urban and the suburban areas. The inclusion of GB emissions substantially improves the simulations of particulate chloride; GB contributes more than 60% of the observation, indicating that it is a major source of particulate chloride in Mexico City. GB yields up to 3 pbb HCl at the ground level in the city, which is mainly caused by the burning of polyvinyl chloride (PVC in the garbage. GB is also an important source of PM2.5, contributing about 3–30% simulated PM2.5 mass on average. More modeling work is needed to evaluate the GB contribution to hazardous air toxics, such as dioxin, which is found to be released at high level from PVC burning in laboratory experiments.

  3. Chloride Transport in Heterogeneous Formation

    Science.gov (United States)

    Mukherjee, A.; Holt, R. M.

    2017-12-01

    The chloride mass balance (CMB) is a commonly-used method for estimating groundwater recharge. Observations of the vertical distribution of pore-water chloride are related to the groundwater infiltration rates (i.e. recharge rates). In CMB method, the chloride distribution is attributed mainly to the assumption of one dimensional piston flow. In many places, however, the vertical distribution of chloride will be influenced by heterogeneity, leading to horizontal movement of infiltrating waters. The impact of heterogeneity will be particularly important when recharge is locally focused. When recharge is focused in an area, horizontal movement of chloride-bearing waters, coupled with upward movement driven by evapotranspiration, may lead to chloride bulges that could be misinterpreted if the CMB method is used to estimate recharge. We numerically simulate chloride transport and evaluate the validity of the CMB method in highly heterogeneous systems. This simulation is conducted for the unsaturated zone of Ogallala, Antlers, and Gatuna (OAG) formations in Andrews County, Texas. A two dimensional finite element model will show the movement of chloride through heterogeneous systems. We expect to see chloride bulges not only close to the surface but also at depths characterized by horizontal or upward movement. A comparative study of focused recharge estimates in this study with available recharge data will be presented.

  4. Surface Properties of a Novel Poly(vinyl alcohol Film Prepared by Heterogeneous Saponification of Poly(vinyl acetate Film

    Directory of Open Access Journals (Sweden)

    Seong Baek Yang

    2017-10-01

    Full Text Available Almost general poly(vinyl alcohol (PVA films were prepared by the processing of a PVA solution. For the first time, a novel poly(vinyl alcohol (PVA film was prepared by the saponification of a poly(vinyl acetate (PVAc film in a heterogenous medium. Under the same saponification conditions, the influence of saponification time on the degree of saponification (DS was studied for the preparation of the saponified PVA film, and it was found that the DS varied with time. Optical microscopy was used to confirm the characteristics and surface morphology of the saponified PVA film, revealing unusual black globules in the film structure. The contact angle of the films was measured to study the surface properties, and the results showed that the saponified PVA film had a higher contact angle than the general PVA film. To confirm the transformation of the PVAc film to the PVA film, 1H nuclear magnetic resonance spectroscopy, X-ray diffraction measurements, differential scanning calorimetry, and Fourier-transform infrared spectroscopy were employed.

  5. Drill pipes and casings utilizing multi-conduit tubular; Flerkanals roerstreng

    Energy Technology Data Exchange (ETDEWEB)

    Curlett, H.B.

    1997-04-23

    The invention relates to a multi-conduit tubular having fluid conduits and electrical conduits, with associated surface fluid and electrical commutators, and downhole sensors for providing surface monitors with instantaneous formation data. Each tubular includes a plurality of uniform linear conduits there through, with a gasket seal plate interposed between joined tubular for assuring a high pressure seal between joined conduits. the seal plate includes an intermediate electrical connector for connecting electrical conduit connectors of one tubular to another. A coupling collar with uniform diameter internal coarse and fine threads joins the tubular ends having similar threads by differential thread action without respective tubular rotation. Each tubular end includes an inter-engaging index recess and index lug, and drive recesses and lugs for maintaining angular registry of the tubular string and for driving one drill tubular with another. A fluid commutator includes a rotating shaft with passages connected to the tubular conduits, and rotating in a manifold having annular grooves in communication with the shaft passages and external fluid sources. An adaptor couples each commutator shaft passage to one or more tubular conduits. Slip rings on a quill shaft and stationary brush means provide electrical continuity from the electrical conduit wires to surface equipment. A cross-over sub includes formation parameter sensors and telemetry equipment in a blocked off portion of a fluid conduit. An annular accumulator connected with the well bore annulus applies a pressure thereto in response to downhole sensors to change the effective density of the drill mud. The multi-conduit tubular is further adapted for use as a well casing to provide downhole access of a plurality of fluids and electrical parameter sensors. 28 figs.

  6. Silicic magma differentiation in ascent conduits. Experimental constraints

    Science.gov (United States)

    Rodríguez, Carmen; Castro, Antonio

    2017-02-01

    Crystallization of water-bearing silicic magmas in a dynamic thermal boundary layer is reproduced experimentally by using the intrinsic thermal gradient of piston-cylinder assemblies. The standard AGV2 andesite under water-undersaturated conditions is set to crystallize in a dynamic thermal gradient of about 35 °C/mm in 10 mm length capsules. In the hotter area of the capsule, the temperature is initially set at 1200 °C and decreases by programmed cooling at two distinct rates of 0.6 and 9.6 °C/h. Experiments are conducted in horizontally arranged assemblies in a piston cylinder apparatus to avoid any effect of gravity settling and compaction of crystals in long duration runs. The results are conclusive about the effect of water-rich fluids that are expelled out the crystal-rich zone (mush), where water saturation is reached by second boiling in the interstitial liquid. Expelled fluids migrate to the magma ahead of the solidification front contributing to a progressive enrichment in the fluxed components SiO2, K2O and H2O. The composition of water-rich fluids is modelled by mass balance using the chemical composition of glasses (quenched melt). The results are the basis for a model of granite magma differentiation in thermally-zoned conduits with application of in-situ crystallization equations. The intriguing textural and compositional features of the typical autoliths, accompanying granodiorite-tonalite batholiths, can be explained following the results of this study, by critical phenomena leading to splitting of an initially homogeneous magma into two magma systems with sharp boundaries. Magma splitting in thermal boundary layers, formed at the margins of ascent conduits, may operate for several km distances during magma transport from deep sources at the lower crust or upper mantle. Accordingly, conduits may work as chromatographic columns contributing to increase the silica content of ascending magmas and, at the same time, leave behind residual mushes that

  7. Characterization of molecule and particle transport through nanoscale conduits

    Science.gov (United States)

    Alibakhshi, Mohammad Amin

    Nanofluidic devices have been of great interest due to their applications in variety of fields, including energy conversion and storage, water desalination, biological and chemical separations, and lab-on-a-chip devices. Although these applications cross the boundaries of many different disciplines, they all share the demand for understanding transport in nanoscale conduits. In this thesis, different elusive aspects of molecule and particle transport through nanofluidic conduits are investigated, including liquid and ion transport in nanochannels, diffusion- and reaction-governed enzyme transport in nanofluidic channels, and finally translocation of nanobeads through nanopores. Liquid or solvent transport through nanoconfinements is an essential yet barely characterized component of any nanofluidic systems. In the first chapter, water transport through single hydrophilic nanochannels with heights down to 7 nm is experimentally investigated using a new measurement technique. This technique has been developed based on the capillary flow and a novel hybrid nanochannel design and is capable of characterizing flow in both single nanoconduits as well as nanoporous media. The presence of a 0.7 nm thick hydration layer on hydrophilic surfaces and its effect on increasing the hydraulic resistance of the nanochannels is verified. Next, ion transport in a new class of nanofluidic rectifiers is theoretically and experimentally investigated. These so called nanofluidic diodes are nanochannels with asymmetric geometries which preferentially allow ion transport in one direction. A nondimensional number as a function of electrolyte concentration, nanochannel dimensions, and surface charge is derived that summarizes the rectification behavior of this system. In the fourth chapter, diffusion- and reaction-governed enzyme transport in nanofluidic channels is studied and the theoretical background necessary for understanding enzymatic activity in nanofluidic channels is presented. A

  8. Twenty years of cable-in-conduit conductors: 1975-1995

    International Nuclear Information System (INIS)

    Dresner, L.

    1995-01-01

    This paper reviews our progress during the last two decades in understanding cable-in-conduit conductors. The emphasis is on the physical principles governing the behavior of cable-in-conduit conductors, and no detailed mathematics is presented. The paper is constructed as a historical narrative

  9. 26 CFR 1.58-2 - General rules for conduit entities; partnerships and partners.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true General rules for conduit entities; partnerships...; partnerships and partners. (a) General rules for conduit entities. Sections 1.58-3 through 1.58-6 provide rules... example, if a trust has $100,000 of capital gains for the taxable year, all of which are distributed to A...

  10. Midterm performance of a novel restorative pulmonary valved conduit: preclinical results

    NARCIS (Netherlands)

    Soliman, Osama I.; Miyazaki, Yosuke; Abdelghani, Mohammad; Brugmans, Marieke; Witsenburg, Maarten; Onuma, Yoshinobu; Cox, Martijn; Serruys, Patrick W.

    2017-01-01

    Aims: The Xeltis bioabsorbable pulmonary valved conduit (XPV), designed to guide functional restoration of patients' own tissue, is potentially more durable than current pulmonary bioprosthetic valves/valved conduits. The aim of this study was to assess the haemodynamic performance of the novel XPV

  11. 78 FR 56872 - City of Barre, Vermont; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-09-16

    ..., Vermont; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting... construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The Nelson Street 17 kW...

  12. 78 FR 66355 - Pleasant Grove City, UT; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-11-05

    ... City, UT; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and... Grove City, Utah (Pleasant Grove) filed a notice of intent to construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower...

  13. 78 FR 61987 - Corbett Water District; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-10-09

    ... District; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting... construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The Corbett Hydroelectric...

  14. 78 FR 53752 - City of Sandpoint, Idaho; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-08-30

    ... Sandpoint, Idaho; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and... intent to construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The Little...

  15. 78 FR 61985 - City of Astoria, Oregon; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-10-09

    ..., Oregon; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting... of intent to construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The...

  16. 78 FR 63176 - Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting...

    Science.gov (United States)

    2013-10-23

    ... Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting Comments and Motions To... of intent to construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The...

  17. Studying the causes for corrosive destruction of water conduits

    Energy Technology Data Exchange (ETDEWEB)

    Azamatova, F I; Kulinichev, G P; Porubov, I S

    1979-01-01

    Pipes from different oil and gas production administrations were selected for X-ray and metallographic studies of the cause of corrosive destruction. The chemical composition and mechanical properties of the pipe material are presented in tables. The phase composition of the corrosion products was studied by X-rays. The complex structure of the layer made up of the corrosion products was taken into consideration. The studies were conducted in an X-ray diffraction chamber. The obtained results are presented in a table. The metallographic studies showed that a significant corrosive damage of the materials of water conduits occurs as a result of the development of local corrosion processes, caused by the substantive heterogeneity of the structure of the metal, related to the nonuniform distribution of the pearlite because of carbon liquidation.

  18. Injunctions against mere conduit of information protected by copyright

    DEFF Research Database (Denmark)

    Sandfeld Jakobsen, Søren; Petersen, Clement Salung

    2011-01-01

    This paper includes an in-depth analysis of EU law and Scandinavian law on injunctions against internet access providers (IAPs) performing as mere conduit of information protected by copyright. In recent Scandinavian case law, courts have granted preliminary injunctions which have caused IAPs...... to either shut down specific internet connections allegedly used to infringe copyright or to block access to internet content, which allegedly infringed applicable copyright rules. This paper considers some significant legal challenges, which are emerging in the wake of this case law, and which should...... requires rules, which take into due consideration the special aspects related to enforcement of copyright on the internet through IAPs. Secondly, it is shown that the termination of internet connections and the blocking of access to internet content may not support the public policies behind copyright law...

  19. Hot upwelling conduit beneath the Atlas Mountains, Morocco

    Science.gov (United States)

    Sun, Daoyuan; Miller, Meghan S.; Holt, Adam F.; Becker, Thorsten W.

    2014-11-01

    The Atlas Mountains of Morocco display high topography, no deep crustal root, and regions of localized Cenozoic alkaline volcanism. Previous seismic imaging and geophysical studies have implied a hot mantle upwelling as the source of the volcanism and high elevation. However, the existence, shape, and physical properties of an associated mantle anomaly are debated. Here we use seismic waveform analysis from a broadband deployment and geodynamic modeling to define the physical properties and morphology of the anomaly. The imaged low-velocity structure extends to ~200 km beneath the Atlas and appears ~350 K hotter than the ambient mantle with possible partial melting. It includes a lateral conduit, which suggests that the Quaternary volcanism arises from the upper mantle. Moreover, the shape and temperature of the imaged anomaly indicate that the unusually high topography of the Atlas Mountains is due to active mantle support.

  20. Investigating the influence of conduit residues on polyurethane plates

    Directory of Open Access Journals (Sweden)

    Rachel Faverzani Magnago

    Full Text Available Abstract Converting waste into a product similar to the original one or into another useful product is to save energy, protect natural resources, and bring back to the production cycle what was discarded. In that direction, new polyurethane-based composites have been developed by incorporating 5%, 10%, 15%, and 20% PVC conduit discarded by the construction industry. The objective of this study was to investigate the interaction between the phases of waste incorporation and the effect upon the new material properties. The samples were produced by the polycondensation process. Microstructural analysis revealed a reduction in pore size across the polymer matrix. However, there were no changes in thermal insulation, water absorption, compressive strength, and burning rate tests and in the thermogravimetric analysis and differential scanning calorimetry. The results from this study showed that the replacement of raw material by waste did not affect its properties.

  1. Cable-in-conduit conductor optimization for fusion magnet applications

    International Nuclear Information System (INIS)

    Miller, J.R.; Kerns, J.A.

    1987-01-01

    Careful design of the toroidal-field (TF) and poloidal-field (PF) coils in a tokamak machine using cable-in-conduit conductors (CICC) can result in quite high overall winding-pack current densities - even with the high nuclear heat loads that may be imposed in operating a fusion reactor - and thereby help reduce the overall machine size. In our design process, we systematically examined the operational environment of a magnet, e.g., mechanical stresses, current, field, heat load, coolant temperature, and cooldown stresses, to determine the optimum amounts of copper, superconductor, helium, and sheath material for the CICC. This process is being used to design the superconducting magnet systems that comprise the Tokamak Ignition/Burn Experimental Reactor (TIBER II). 13 refs., 2 figs

  2. Valyl benzyl ester chloride

    Directory of Open Access Journals (Sweden)

    Grzegorz Dutkiewicz

    2010-02-01

    Full Text Available In the title compound (systematic name: 1-benzyloxy-3-methyl-1-oxobutan-2-aminium chloride, C12H18NO2+·Cl−, the ester group is approximately planar, with a maximum deviation of 0.040 (2 Å from the least-squares plane, and makes a dihedral angle of 28.92 (16° with the phenyl ring. The crystal structure is organized by N—H...Cl hydrogen bonds which join the two components into a chain along the b axis. Pairs of chains arranged antiparallel are interconnected by further N—H...Cl hydrogen bonds, forming eight-membered rings. Similar packing modes have been observed in a number of amino acid ester halides with a short unit-cell parameter of ca 5.5 Å along the direction in which the chains run.

  3. Chloride on the Move

    KAUST Repository

    Li, Bo

    2017-01-09

    Chloride (Cl−) is an essential plant nutrient but under saline conditions it can accumulate to toxic levels in leaves; limiting this accumulation improves the salt tolerance of some crops. The rate-limiting step for this process – the transfer of Cl− from root symplast to xylem apoplast, which can antagonize delivery of the macronutrient nitrate (NO3−) to shoots – is regulated by abscisic acid (ABA) and is multigenic. Until recently the molecular mechanisms underpinning this salt-tolerance trait were poorly defined. We discuss here how recent advances highlight the role of newly identified transport proteins, some that directly transfer Cl− into the xylem, and others that act on endomembranes in ‘gatekeeper’ cell types in the root stele to control root-to-shoot delivery of Cl−.

  4. Novel technique for airless connection of artificial heart to vascular conduits.

    Science.gov (United States)

    Karimov, Jamshid H; Gao, Shengqiang; Dessoffy, Raymond; Sunagawa, Gengo; Sinkewich, Martin; Grady, Patrick; Sale, Shiva; Moazami, Nader; Fukamachi, Kiyotaka

    2017-12-01

    Successful implantation of a total artificial heart relies on multiple standardized procedures, primarily the resection of the native heart, and exacting preparation of the atrial and vascular conduits for pump implant and activation. Achieving secure pump connections to inflow/outflow conduits is critical to a successful outcome. During the connection process, however, air may be introduced into the circulation, traveling to the brain and multiple organs. Such air emboli block blood flow to these areas and are detrimental to long-term survival. A correctly managed pump-to-conduit connection prevents air from collecting in the pump and conduits. To further optimize pump-connection techniques, we have developed a novel connecting sleeve that enables airless connection of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) to the conduits. In this brief report, we describe the connecting sleeve design and our initial results from two acute in vivo implantations using a scaled-down version of the CFTAH.

  5. Development and Implementation of a Segment/Junction Box Level Database for the ITS Fiber Optic Conduit Network

    Science.gov (United States)

    2012-03-01

    This project initiated the development of a computerized database of ITS facilities, including conduits, junction : boxes, cameras, connections, etc. The current system consists of a database of conduit sections of various lengths. : Over the length ...

  6. Polyvinyl Alcohol-Lead Nitrate Paint for Gamma Radiation Installations

    International Nuclear Information System (INIS)

    EI-Ahdal, M.A.

    2007-01-01

    Dealing with gamma ray installations represents an important problem for radiation protection workers. Radiation shielding is used to avoid the risk resulting from these gamma sources. This study suggested the use of polyvinyl alcohol (PVA) solution that contains lend nitrate (with lead metal/PVA= 1.72) to lower the gamma radiation intensity and reduce its risk to workers. This can be achieved by painting the radiation shielding with this solution Temperature relief of the irradiated solution shows the degradation of the polymer content up to 50 degree C, which starts to crosslink increasing the protection capability of this solution

  7. Memristive learning and memory functions in polyvinyl alcohol polymer memristors

    Directory of Open Access Journals (Sweden)

    Yan Lei

    2014-07-01

    Full Text Available Polymer based memristive devices can offer simplicity in fabrication and at the same time promise functionalities for artificial neural applications. In this work, inherent learning and memory functions have been achieved in polymer memristive devices employing Polyvinyl Alcohol. The change in conduction in such polymer devices strongly depends on the pulse amplitude, duration and time interval. Through repetitive stimuli training, temporary short-term memory can transfer into consolidated long-term memory. These behaviors bear remarkable similarities to certain learning and memory functions of biological systems.

  8. Sodium deoxycholate functionalized graphene and its composites with polyvinyl alcohol

    International Nuclear Information System (INIS)

    Wang Lanwei; Liao Ruijuan; Tang Zhenghai; Lei Yanda; Guo Baochun

    2011-01-01

    Sodium deoxycholate (SDC), a kind of bile derivative, is used to noncovalently functionalize graphene. Stable and high concentration (up to 20 mg ml -1 ) of graphene colloid is obtained. The stabilization mechanism is revealed to be hydrophobic interaction, electrostatic repulsion and hydrogen bonding. Single-layer and few-layer graphene are obtained in the colloid. Subsequently, the obtained graphene sheets are incorporated into a polyvinyl alcohol (PVA) matrix by solution casting to fabricate PVA/graphene composites. Morphological observations substantiate the homogeneous dispersion of graphene in the PVA matrix and strong interfacial adhesion between them. Significant improvements in tensile strength and modulus of the composite films are observed.

  9. Engineering a multimodal nerve conduit for repair of injured peripheral nerve

    Science.gov (United States)

    Quigley, A. F.; Bulluss, K. J.; Kyratzis, I. L. B.; Gilmore, K.; Mysore, T.; Schirmer, K. S. U.; Kennedy, E. L.; O'Shea, M.; Truong, Y. B.; Edwards, S. L.; Peeters, G.; Herwig, P.; Razal, J. M.; Campbell, T. E.; Lowes, K. N.; Higgins, M. J.; Moulton, S. E.; Murphy, M. A.; Cook, M. J.; Clark, G. M.; Wallace, G. G.; Kapsa, R. M. I.

    2013-02-01

    Injury to nerve tissue in the peripheral nervous system (PNS) results in long-term impairment of limb function, dysaesthesia and pain, often with associated psychological effects. Whilst minor injuries can be left to regenerate without intervention and short gaps up to 2 cm can be sutured, larger or more severe injuries commonly require autogenous nerve grafts harvested from elsewhere in the body (usually sensory nerves). Functional recovery is often suboptimal and associated with loss of sensation from the tissue innervated by the harvested nerve. The challenges that persist with nerve repair have resulted in development of nerve guides or conduits from non-neural biological tissues and various polymers to improve the prognosis for the repair of damaged nerves in the PNS. This study describes the design and fabrication of a multimodal controlled pore size nerve regeneration conduit using polylactic acid (PLA) and (PLA):poly(lactic-co-glycolic) acid (PLGA) fibers within a neurotrophin-enriched alginate hydrogel. The nerve repair conduit design consists of two types of PLGA fibers selected specifically for promotion of axonal outgrowth and Schwann cell growth (75:25 for axons; 85:15 for Schwann cells). These aligned fibers are contained within the lumen of a knitted PLA sheath coated with electrospun PLA nanofibers to control pore size. The PLGA guidance fibers within the nerve repair conduit lumen are supported within an alginate hydrogel impregnated with neurotrophic factors (NT-3 or BDNF with LIF, SMDF and MGF-1) to provide neuroprotection, stimulation of axonal growth and Schwann cell migration. The conduit was used to promote repair of transected sciatic nerve in rats over a period of 4 weeks. Over this period, it was observed that over-grooming and self-mutilation (autotomy) of the limb implanted with the conduit was significantly reduced in rats implanted with the full-configuration conduit compared to rats implanted with conduits containing only an alginate

  10. Swelling and mechanical properties of physically crosslinked poly(vinyl alcohol) hydrogels.

    Science.gov (United States)

    Suzuki, Atsushi; Sasaki, Saori

    2015-12-01

    Physically crosslinked poly(vinyl alcohol) gels are versatile biomaterials due to their excellent biocompatibility. In the past decades, physically crosslinked poly(vinyl alcohol) and poly(vinyl alcohol)-based hydrogels have been extensively studied for biomedical applications. However, these materials have not yet been implemented due to their mechanical strength. Physically crosslinked poly(vinyl alcohol) gels consist of a swollen amorphous network of poly(vinyl alcohol) physically crosslinked by microcrystallites. Although the mechanical properties can be improved to some extent by controlling the distribution of microcrystallites on the nano- and micro-scales, enhancing the mechanical properties while maintaining high water content remains very difficult. It may be technologically impossible to significantly improve the mechanical properties while keeping the gel's high water absorbance ability using conventional fabrication methods. Physical and chemical understandings of the swelling and mechanical properties of physically crosslinked poly(vinyl alcohol) gels are considered here; some promising strategies for their practical applications are presented. This review focuses more on the recent studies on swelling and mechanical properties of poly(vinyl alcohol) hydrogels, prepared using only poly(vinyl alcohol) and pure water with no other chemicals, as potential biomedical materials. © IMechE 2015.

  11. Cerium(terbium, erbium)chloride-choline chloride aqueous systems

    International Nuclear Information System (INIS)

    Gajfutdinova, R.K.; Zhuravlev, E.F.; Bikbaeva, G.G.; Domrachev, V.N.; Vanskova, G.I.

    1985-01-01

    To clarify the effect of rare earth nature on mutual solubility of rare earth salts and amines the solubility of solid phases in the systems, consisting of choline chloride, water and cerium, terbium, erbium chlorides, has been studied. It is established, that solubility isotherms of all the systems, testify to the formation of new solid phases of the composition: Ce(Tb, Er)xCl 3 x2C 5 H 14 ONClx3H 2 O. Individuality of new solid phases is proved by DTA method, the composition is confirmed by chemical analysis and data of PMR spectra, for choline chloride and its complexes with rare earth chlorides of the given composition PMR and IR spectra are studied

  12. Effect of Saponification Condition on the Morphology and Diameter of the Electrospun Poly(vinyl acetate) Nanofibers for the Fabrication of Poly(vinyl alcohol) Nanofiber Mats

    OpenAIRE

    Seong Baek Yang; Jong Won Kim; Jeong Hyun Yeum

    2016-01-01

    Novel poly(vinyl alcohol) (PVA) nanofiber mats were prepared for the first time through heterogeneous saponification of electrospun poly(vinyl acetate) (PVAc) nanofibers. The effect of varying the saponification conditions, including temperature, time, and concentration of the alkaline solution, on the morphology of the saponified PVA fibers were evaluated by field-emission scanning electron microscopy. At 25 °C, the saponified PVA fibers exhibited a broad diameter distribution. The average f...

  13. Degradation properties of the electrostatic assembly PDLLA/CS/CHS nerve conduit

    Energy Technology Data Exchange (ETDEWEB)

    Xu Haixing [School of Chemical Engineering, Wuhan University of Technology, Wuhan 430070 (China); Yan Yuhua; Wan Tao; Li Shipu, E-mail: yanyuhua8@126.co [Biomedical Materials and Engineering Research Center, Wuhan University of Technology, Wuhan 430070 (China)

    2009-08-15

    A poly(d,l-lactic acid)/chondroitin sulfate/chitosan (PDLLA/CS/CHS) nerve conduit for repairing nerve defects was prepared by electrostatic assembly and the thermally induced phase separation technique. The hydrophilic characteristics of the PDLLA/CS/CHS assembly nerve conduits were improved markedly. The degradation behavior of the nerve conduit with various assembly layers was evaluated by a pH change, weight loss rate and molecular weight change. The pH of the solution of the nerve conduit could be effectively adjusted by varying the layer numbers and overcoming the acidity-caused auto-acceleration of PDLLA; the nerve conduit can retain its integrity in a phosphate buffer solution after being degraded for 3 months. After such a conduit was implanted in the rat for 3 months, obvious degradation occurred, but the regenerated nerve was integrated and it grew successfully from the proximal to distal nerve stump. All these results implied that the degradation rate of the prepared conduit can adapt to the regeneration of the peripheral nerve, which might be a new derivative of PDLLA-based biodegradable materials for repairing nerve injuries without acidity-caused irritations and acidity-induced auto-accelerating degradation behavior as shown by PDLLA.

  14. Contribution of Charges in Polyvinyl Alcohol Networks to Marine Antifouling.

    Science.gov (United States)

    Yang, Wufang; Lin, Peng; Cheng, Daocang; Zhang, Longzhou; Wu, Yang; Liu, Yupeng; Pei, Xiaowei; Zhou, Feng

    2017-05-31

    Semi-interpenetrated polyvinyl alcohol polymer networks (SIPNs) were prepared by integrating various charged components into polyvinyl alcohol polymer. Contact angle measurement, attenuated total reflection Fourier transform infrared spectroscopy, field emission scanning electron microscopy, and tensile tests were used to characterize the physicochemical properties of the prepared SIPNs. To investigate the contribution of charges to marine antifouling, the adhesion behaviors of green algae Dunaliella tertiolecta and diatoms Navicula sp. in the laboratory and of the actual marine animals in field test were studied for biofouling assays. The results suggest that less algae accumulation densities are observed for neutral-, anionic-, and zwitterionic-component-integrated SIPNs. However, for the cationic SIPNs, despite the hydration shell induced by the ion-dipole interaction, the resistance to biofouling largely depends on the amount of cationic component because of the possible favorable electrostatic attraction between the cationic groups in SIPNs and the negatively charged algae. Considering that the preparation of novel nontoxic antifouling coating is a long-standing and cosmopolitan industrial challenge, the SIPNs may provide a useful reference for marine antifouling and some other relevant fields.

  15. Insulating characteristics of polyvinyl alcohol for integrated electronics

    International Nuclear Information System (INIS)

    Van Etten, Eliana A.; Ximenes, Eder S.; Tarasconi, Lucas T.; Garcia, Irene T.S.; Forte, Maria M.C.; Boudinov, Henri

    2014-01-01

    The aim of this work is to evaluate the effects of molecular weight, hydrolysis degree, and cross-link on the performance of Polyvinyl Alcohol (PVA) when applied as dielectric material in organic field effect transistors. For this purpose, metal–insulator-structures and polymeric films were characterized. The polymer structure was analyzed by thermogravimetry and calorimetry, and the electrical characterization of the films was performed through current–voltage and capacitance–voltage curves; and dielectric spectrometry. Cross-linkage, followed by hydrolysis degree, presented the major impact on polymer properties, due to the strong influence on chain mobility. The chain mobility increases the dielectric response and decreases the insulation capacity, generating the need to compromise between these two properties. The largest drawback encountered was the high sensitivity of the films to ambient humidity. The best performance of the organic insulator was obtained from cross-linked films made of an incompletely hydrolyzed PVA. - Highlights: • Effect of molecular weight, hydrolysis and cross-link on polyvinyl alcohol (PVA) dielectric • Cross-linkage, followed by hydrolysis, showed the major impact on properties. • Cross-linkage followed by hydrolysis showed the strongest effect on chain mobility. • Best dielectric performance: cross-linked films made of incompletely hydrolyzed PVA • Largest drawback is the high sensitivity of the films to ambient humidity

  16. Hydrothermal Alteration of the Mt Unzen Conduit (Shimabara/Japan)

    Science.gov (United States)

    Yilmaz, T. I.; Mayer, K.; Hess, K. U.; Janots, E.; Gilg, H. A.; Dingwell, D. B.

    2016-12-01

    Investigations were carried out on hydrothermally altered coherent dacitic dykes samples from (USDP-4) drill core at Mt Unzen stratovolcano (Shimabara/Japan). XRF, XRD, EMPA, and C-O-isotope analysis led to insights concerning chemistry, mineralogy, and intensity of alteration as well as the origin of carbonate-precipitating fluids. Additionally a textural characterization of the occurring replacement features in the magma conduit zone was performed. The occurrence of the main secondary phases such as chlorite, pyrite, carbonates, and R1 (Reichweite parameter) illite-smectite indicate a weak to moderate propylitic to phyllic hydrothermal alteration. The dacitic samples of the dykes show different hydrothermal alteration features: (i) carbonate pseudomorphs after hornblende as well as core and zonal textures due to replacement of plagioclase by R1 illite-smectite, (ii) colloform banded fracture fillings and fillings in dissolution vugs, and (iii) chlorite and R1 illite-smectite in the groundmass. Carbonates in fractures comprise iron-rich dolomite solid solutions ("ankerite") and calcite. Isotopic values of d13Cvpdb = -4.59 ± 0.6‰ and d18Ovpdb = -21.73 ± 0.5‰ indicate a hydrothermal-magmatic origin for the carbonate formation. The chlorite-carbonate-pyrite index (CCPI) and the Ishikawa alteration index (AI), applied to the investigated samples show significant differences (CCPI=52.7-57.8; AI=36.1-40.6) indicating their different degree of alteration. According to Nakada et al., 2005, the C13 to C16 dykes represent the feeder dyke from the latest eruption (1991-1995) whereas C8 represents an earlier dyke feeder dyke from an older eruption. Weakest conduit alteration, which was obtained in samples C16-1-5 and C13-2-5, correlates with the alteration degree of the pristine dome rocks. Highest CCPI value was determined for sample C14-1-5 and the highest AI value was determined for sample C15-2-6. The degrees of alteration do not indicate highest alteration of the

  17. Chloride removal from plutonium alloy

    International Nuclear Information System (INIS)

    Holcomb, H.P.

    1983-01-01

    SRP is evaluating a program to recover plutonium from a metallic alloy that will contain chloride salt impurities. Removal of chloride to sufficiently low levels to prevent damaging corrosion to canyon equipment is feasible as a head-end step following dissolution. Silver nitrate and mercurous nitrate were each successfully used in laboratory tests to remove chloride from simulated alloy dissolver solution containing plutonium. Levels less than 10 ppM chloride were achieved in the supernates over the precipitated and centrifuged insoluble salts. Also, less than 0.05% loss of plutonium in the +3, +4, or +6 oxidation states was incurred via precipitate carrying. These results provide impetus for further study and development of a plant-scale process to recover plutonium from metal alloy at SRP

  18. Conduits to care: call lights and patients’ perceptions of communication

    Science.gov (United States)

    Montie, Mary; Shuman, Clayton; Galinato, Jose; Patak, Lance; Anderson, Christine A; Titler, Marita G

    2017-01-01

    Background Call light systems remain the primary means of hospitalized patients to initiate communication with their health care providers. Although there is vast amounts of literature discussing patient communication with their health care providers, few studies have explored patients’ perceptions concerning call light use and communication. The specific aim of this study was to solicit patients’ perceptions regarding their call light use and communication with nursing staff. Methods Patients invited to this study met the following inclusion criteria: proficient in English, been hospitalized for at least 24 hours, aged ≥21 years, and able to communicate verbally (eg, not intubated). Thirty participants provided written informed consent, were enrolled in the study, and completed interviews. Results Using qualitative descriptive methods, five major themes emerged from patients’ perceptions (namely; establishing connectivity, participant safety concerns, no separation: health care and the call light device, issues with the current call light, and participants’ perceptions of “nurse work”). Multiple minor themes supported these major themes. Data analysis utilized the constant comparative methods of Glaser and Strauss. Discussion Findings from this study extend the knowledge of patients’ understanding of not only why inconsistencies occur between the call light and their nurses, but also why the call light is more than merely a device to initiate communication; rather, it is a direct conduit to their health care and its delivery. PMID:29075125

  19. Conduits to care: call lights and patients' perceptions of communication.

    Science.gov (United States)

    Montie, Mary; Shuman, Clayton; Galinato, Jose; Patak, Lance; Anderson, Christine A; Titler, Marita G

    2017-01-01

    Call light systems remain the primary means of hospitalized patients to initiate communication with their health care providers. Although there is vast amounts of literature discussing patient communication with their health care providers, few studies have explored patients' perceptions concerning call light use and communication. The specific aim of this study was to solicit patients' perceptions regarding their call light use and communication with nursing staff. Patients invited to this study met the following inclusion criteria: proficient in English, been hospitalized for at least 24 hours, aged ≥21 years, and able to communicate verbally (eg, not intubated). Thirty participants provided written informed consent, were enrolled in the study, and completed interviews. Using qualitative descriptive methods, five major themes emerged from patients' perceptions (namely; establishing connectivity, participant safety concerns, no separation: health care and the call light device, issues with the current call light, and participants' perceptions of "nurse work"). Multiple minor themes supported these major themes. Data analysis utilized the constant comparative methods of Glaser and Strauss. Findings from this study extend the knowledge of patients' understanding of not only why inconsistencies occur between the call light and their nurses, but also why the call light is more than merely a device to initiate communication; rather, it is a direct conduit to their health care and its delivery.

  20. Relaxation of microparticles exposed to hydrodynamic forces in microfluidic conduits.

    Science.gov (United States)

    Janča, Josef; Halabalová, Věra; Polášek, Vladimír; Vašina, Martin; Menshikova, Anastasia Yu

    2011-02-01

    The behavior of microparticles exposed to gravitational and lift forces and to the velocity gradient in flow velocity profile formed in microfluidic conduits is studied from the viewpoint of the transient period (the relaxation) between the moment at which a particle starts to be transported by the hydrodynamic flow and the time at which it reaches an equilibrium position, characterized by a balance of all active forces. The theoretical model allowing the calculation of the relaxation time is proposed. The numerical calculus based on the proposed model is compared with the experimental data obtained under different experimental conditions, namely, for different lengths of microfluidic channels, different average linear velocities of the carrier liquid, and different sizes and densities of the particles used in the study. The results are important for the optimization of microfluidic separation units such as microthermal field-flow fractionation channels in which the separation or manipulation of the microparticles of various origin, synthetic, natural, biological, etc., is performed under similar experimental conditions but by applying an additional thermodynamic force.

  1. Dynamic electrochemical measurement of chloride ions

    NARCIS (Netherlands)

    Abbas, Yawar; de Graaf, Derk B.; Olthuis, Wouter; van den Berg, Albert

    2016-01-01

    This protocol describes the dynamic measurement of chloride ions using the transition time of a silver silver chloride (Ag/AgCl) electrode. Silver silver chloride electrode is used extensively for potentiometric measurement of chloride ions concentration in electrolyte. In this measurement,

  2. Producing ammonium chloride from coal or shale

    Energy Technology Data Exchange (ETDEWEB)

    Christenson, O L

    1921-02-25

    Process of producing ammonium chloride consists of mixing the substance to be treated with a chloride of an alkali or alkaline earth metal, free silica, water and free hydrochloric acid, heating the mixture until ammonium chloride distills off and collecting the ammonium chloride.

  3. 21 CFR 184.1138 - Ammonium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ammonium chloride. 184.1138 Section 184.1138 Food... Specific Substances Affirmed as GRAS § 184.1138 Ammonium chloride. (a) Ammonium chloride (NH4Cl, CAS Reg. No. 12125-02-9) is produced by the reaction of sodium chloride and an ammonium salt in solution. The...

  4. 21 CFR 173.375 - Cetylpyridinium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Cetylpyridinium chloride. 173.375 Section 173.375... CONSUMPTION Specific Usage Additives § 173.375 Cetylpyridinium chloride. Cetylpyridinium chloride (CAS Reg. No....1666 of this chapter, at a concentration of 1.5 times that of cetylpyridinium chloride. (c) The...

  5. 21 CFR 184.1622 - Potassium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Potassium chloride. 184.1622 Section 184.1622 Food... Specific Substances Affirmed as GRAS § 184.1622 Potassium chloride. (a) Potassium chloride (KCl, CAS Reg... levels not to exceed current good manufacturing practice. Potassium chloride may be used in infant...

  6. 21 CFR 184.1426 - Magnesium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Magnesium chloride. 184.1426 Section 184.1426 Food... Specific Substances Affirmed as GRAS § 184.1426 Magnesium chloride. (a) Magnesium chloride (MgC12·6H2O, CAS... hydrochloric acid solution and crystallizing out magnesium chloride hexahydrate. (b) The ingredient meets the...

  7. Investigation of the primary plasticisers present in polyvinyl chloride (PVC) products currently authorised as food contact materials.

    Science.gov (United States)

    Carlos, Katherine S; de Jager, Lowri S; Begley, Timothy H

    2018-03-15

    PVC is a common food contact material that is usually plasticised to increase its flexibility. Phthalates are one class of chemical compounds that are often used as plasticisers in PVC in a wide range of industries. They may be used in packaging materials for foods and can also be found in components of certain food processing equipment such as conveyor belts and tubing. Transfer of plasticisers from packaging to foods can occur. In recent years, there has been increased interest in understanding the health effects of phthalates, as well as the possible human exposure levels. However, there is limited information available about the routes of exposure to phthalates. In July 2014, the Chronic Hazard Advisory Panel (CHAP) produced a report for the U.S. Consumer Product Safety Commission detailing the potential health hazards of phthalates and phthalate alternatives. This report listed diet as one factor contributing greater than or equal to 10% of total phthalate exposure. As a result of this report, the U.S. Food and Drug Administration (FDA) is interested in determining the types of the primary plasticiser present in food packaging and processing materials as well as their concentrations. An investigation was conducted of 56 different samples of PVC food packaging and food processing materials available in the US market using a solvent extraction and GC-MS analysis. Nine different plasticisers including three phthalates, di(2-ethylhexyl) phthalate, diisononyl phthalate and diisodecyl phthalate, were identified in the products tested. The plasticiser concentrations ranged from 1 to 53% depending on the types of food contact materials and the type of plasticiser. Overall, it appears that manufacturers are switching away from phthalates as their primary plasticiser to alternate compounds such as ESBO, ATBC, DEHT, DINCH, DEHA and DINA.

  8. Investigation of fatigue and mechanical properties of the pipe grade poly(vinyl chloride using recycled scraps

    Directory of Open Access Journals (Sweden)

    J-M. Lee

    2015-04-01

    Full Text Available In this paper, the effect of using pre-consumer PVC scraps on static and long-term mechanical properties is studied. The degradation characteristics of mixing virgin PVC with crushed pre-consumer and PVC pipe scraps are analyzed using various tools including Gel Permeation Chromatography (GPC, Thermogravimetric Analysis (TGA, X-ray fluorescence (XRF and Fourier Transform Infrared (FTIR spectroscopy. The variation of static mechanical properties as a function of adding pre-consumer PVC pipe scraps is investigated using the degradation analyses of recycled PVC scraps. In addition, fatigue tests are executed to evaluate the long-term durability of blending virgin PVC and recycled PVC scraps, and the fracture surface is investigated in detail to reveal the variation of the fracture mechanisms.

  9. Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases.

    Science.gov (United States)

    Gupta, Vinod K; Al Khayat, Maysoon; Singh, Ashok K; Pal, Manoj K

    2009-02-16

    The construction and performance characteristics of polymeric membrane electrodes based on two neutral ionophores, 2,2'-(1Z,1'Z)-(1E,1'E)-(1,2-phenylenebis(methan-1-yl-1-ylidene))bis(azaan-1-yl-1-ylidene)bis(methylene)bis(azan-1-yl-1-ylidene)bis(methan-1-yl-ylidene)diphenol (L(1)) and 4,4'-(1E,1'E)-(butane-1,4-diylbis(azan-1-yl-1-ylidene))bis(methan-1-yl-1-ylidene)dinaphthalen-1-ol (L(2)) for quantification of cadmium ions, are described. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w) of (L(1)) (2.6%):PVC (31.6%):DOP (63.2%):NaTPB (2.6%). The proposed electrode exhibits Nernstian response in the concentration range 5.0 x 10(-9) to 1.0 x 10(-1)M Cd(2+) with limit of detection 3.1 x 10(-9), performs satisfactorily over wide pH range (2.0-8.5) with a fast response time (11s). The electrode has been found to work satisfactorily in partially non-aqueous media up to 40% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 2.5 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in cigarette samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants.

  10. Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases

    International Nuclear Information System (INIS)

    Gupta, Vinod K.; Al Khayat, Maysoon; Singh, Ashok K.; Pal, Manoj K.

    2009-01-01

    The construction and performance characteristics of polymeric membrane electrodes based on two neutral ionophores, 2,2'-(1Z,1'Z)-(1E,1'E)-(1,2-phenylenebis(methan-1-yl-1-ylidene)) bis(azaan-1-yl-1-ylidene)bis(methylene)bis(azan-1-yl-1-ylidene) bis(methan-1-yl-ylidene)diphenol (L 1 ) and 4,4'-(1E,1'E)-(butane-1,4-diylbis(azan-1-yl-1-ylidene)) bis(methan-1-yl-1-ylidene)dinaphthalen-1-ol (L 2 ) for quantification of cadmium ions, are described. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w) of (L 1 ) (2.6%):PVC (31.6%):DOP (63.2%):NaTPB (2.6%). The proposed electrode exhibits Nernstian response in the concentration range 5.0 x 10 -9 to 1.0 x 10 -1 M Cd 2+ with limit of detection 3.1 x 10 -9 , performs satisfactorily over wide pH range (2.0-8.5) with a fast response time (11 s). The electrode has been found to work satisfactorily in partially non-aqueous media up to 40% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 2.5 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in cigarette samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants

  11. Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Vinod K. [Department of Chemistry, Indian Institute of Technology Roorkee, Roorkee 247 667 (India)], E-mail: vinodfcy@iitr.ernet.in; Al Khayat, Maysoon [Department of Chemistry, College of Sciences, University of Sharjah, Sharjah (United Arab Emirates); Singh, Ashok K.; Pal, Manoj K. [Department of Chemistry, Indian Institute of Technology Roorkee, Roorkee 247 667 (India)

    2009-02-16

    The construction and performance characteristics of polymeric membrane electrodes based on two neutral ionophores, 2,2'-(1Z,1'Z)-(1E,1'E)-(1,2-phenylenebis(methan-1-yl-1-ylidene)) bis(azaan-1-yl-1-ylidene)bis(methylene)bis(azan-1-yl-1-ylidene) bis(methan-1-yl-ylidene)diphenol (L{sub 1}) and 4,4'-(1E,1'E)-(butane-1,4-diylbis(azan-1-yl-1-ylidene)) bis(methan-1-yl-1-ylidene)dinaphthalen-1-ol (L{sub 2}) for quantification of cadmium ions, are described. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w) of (L{sub 1}) (2.6%):PVC (31.6%):DOP (63.2%):NaTPB (2.6%). The proposed electrode exhibits Nernstian response in the concentration range 5.0 x 10{sup -9} to 1.0 x 10{sup -1} M Cd{sup 2+} with limit of detection 3.1 x 10{sup -9}, performs satisfactorily over wide pH range (2.0-8.5) with a fast response time (11 s). The electrode has been found to work satisfactorily in partially non-aqueous media up to 40% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 2.5 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in cigarette samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants.

  12. Effects of interfacial interaction on the properties of poly(vinyl chloride)/styrene-butadiene rubber blends

    Science.gov (United States)

    Zhu, Shuihan

    PVC/SBR blends---new thermoplastic elastomer material---were developed. They have potential applications due to low costs and low-temperature elasticity. A unique compatibilization method was employed to enhance the mechanical properties of the materials a compatibilizer miscible with one of the blend components can react chemically with the other component(s). Improvements in tensile and impact behavior were observed as a result of the compatibilization. A novel characterization technique to study the interface of PVC/SBR blends was developed. This technique involves the observation of the unstained sample under electron beam irradiation by a transmission electron microscope (TEM). An enrichment of rubber at the interface between PVC and SBR was detected in the compatiblized PVC/SBR blends. Magnetic relaxation measurements show that the rubber concentration in the proximity of PVC increases with the degree of covulcanization between NBR and SBR. The interface development and the rheological effect during processing were investigated. The interfacial concentration profile and the interfacial thickness were obtained by grayscale measurements on TEM micrographs, evaluation of SIMS images, and measurements of micromechanical properties.

  13. Photostability Characterization of Wood Polymer Composites of Polyvinyl Chloride and Rice Husk to Ultra-Violet Irradiation Exposure

    Directory of Open Access Journals (Sweden)

    Jais Farhana Hazwanee M.

    2016-01-01

    Full Text Available In this study, the photostability of wood polymer composites (WPC was assessed by using ultra-violet accelerated weathering test. Meanwhile, the mechanical properties of WPC show strength improvement at prolonged UV irradiation exposure with 43.21 MPa and maximum strain of 4.08 % at 5000 hours and 1000 hours UV irradiation exposure respectively. The colour stability of WPC was improved by addition of Ultraviolet (UV stabilizer during pre-mixing process which shows positive effect on the colour stability and prevented chalking of the composites for external use. Generally, discolourations of WPC during test exposure were caused by degradation of both wood and plastic. Therefore, incorporation with pigments and other additives gives improvement to the photostability of WPC. This is based on the increment of WPCs mechanical property while the morphological fracture surface of dumbbell test specimens revealed the pull out rice husk fiber which contributed to the distribution of load in the WPC samples.

  14. Studies on the thermal and electrical properties of polyethylene oxide/polyvinyl alcohol blend by incorporating of Cesium Chloride

    Science.gov (United States)

    Ragab, H. M.

    The composites PVA/PEO filled with various concentrations of CsCl samples, which were prepared for using a solvent casting technique and studied via Fourier transform infrared spectroscopy (FTIR), ultraviolet - visible (UV-Vis), X-ray spectroscopy, Scanning electron microscopy (SEM), AC conductivity and dielectric properties to use as sensor in electronic devices. The FTIR indicated the interaction between PVA/PEO and CsCl. From data of UV. Vis. was observed band gap (Eg) reduces with addition CsCl to polymer blend. The XRD shows the degree of crystallinity (χ%) decreasing with increasing concentration of CsCl from 2.93 to 2.45. The SEM of the surface of composite PVA/PEO filled with various concentrations of CsCl in magnification 1500 times its change with compare of pure blend. From TGA was observed improvement in the thermal stability of the samples after addition of CsCl. The AC conductivity rise more rapidly with temperature and associated with activation energy Ea, for conduction and enhanced with increasing both temperature and frequency.

  15. Studies on the thermal and electrical properties of polyethylene oxide/polyvinyl alcohol blend by incorporating of Cesium Chloride

    Directory of Open Access Journals (Sweden)

    H.M. Ragab

    Full Text Available The composites PVA/PEO filled with various concentrations of CsCl samples, which were prepared for using a solvent casting technique and studied via Fourier transform infrared spectroscopy (FTIR, ultraviolet – visible (UV–Vis, X-ray spectroscopy, Scanning electron microscopy (SEM, AC conductivity and dielectric properties to use as sensor in electronic devices. The FTIR indicated the interaction between PVA/PEO and CsCl. From data of UV. Vis. was observed band gap (Eg reduces with addition CsCl to polymer blend. The XRD shows the degree of crystallinity (χ% decreasing with increasing concentration of CsCl from 2.93 to 2.45. The SEM of the surface of composite PVA/PEO filled with various concentrations of CsCl in magnification 1500 times its change with compare of pure blend. From TGA was observed improvement in the thermal stability of the samples after addition of CsCl. The AC conductivity rise more rapidly with temperature and associated with activation energy Ea, for conduction and enhanced with increasing both temperature and frequency. Keywords: PVA/PEO composite, X-ray, TGA, AC conductivity, Dielectric loss

  16. Empirical Study on Sustainable Opportunities Recognition. A Polyvinyl Chloride (PVC Joinery Industry Analysis Using Augmented Sustainable Development Process Model

    Directory of Open Access Journals (Sweden)

    Eduard-Gabriel Ceptureanu

    2017-09-01

    Full Text Available This paper analyzes factors influencing recognition of sustainable opportunities by using an augmented sustainability process model. The conceptual model used two main factors, Knowledge and Motivation, and one moderating variable, Social embeddedness. We investigated entrepreneurs from PVC joinery industry and concluded that while market orientation and sustainable entrepreneurial orientation definitely and positively influence sustainable opportunity recognition, others variables like knowledge of the natural/communal environment, awareness of sustainable development or focus on success have less support. Among all variables analyzed, perception of the threat of the natural/communal environment and altruism toward others have the poorest impact on opportunity recognition. Finally, we concluded that social embeddedness has a moderating effect on sustainable opportunity recognition, even though the results were mixed.

  17. Flexible and strong ternary blends of poly(vinyl chloride), poly(butylene adipate)and nanoparticle-plasticizers

    OpenAIRE

    Yin, Bo; Hakkarainen, Minna

    2013-01-01

    Multiple property enhancement was achieved for ternary blends of PVC, poly(butylene adipate) (PBA) plasticizer and PBA-grafted nanofillers as compared to ternary blends with untreated nanofillers. The blends with surface modified halloysite, kaolin or silicon dioxide nanofillers all exhibited higher stress at break and higher strain at break as compared to the corresponding composites with untreated nanoparticles. The strain at break was similar or improved compared to binary PVC/PBA blends. ...

  18. Surface reaction rate and probability of ozone and alpha-terpineol on glass, polyvinyl chloride, and latex paint surfaces.

    Science.gov (United States)

    Shu, Shi; Morrison, Glenn C

    2011-05-15

    Ozone can react homogeneously with unsaturated organic compounds in buildings to generate undesirable products. However, these reactions can also occur on indoor surfaces, especially for low-volatility organics. Conversion rates of ozone with α-terpineol, a representative low-volatility compound, were quantified on surfaces that mimic indoor substrates. Rates were measured for α-terpineol adsorbed to beads of glass, polyvinylchloride (PVC), and dry latex paint, in a plug flow reactor. A newly defined second-order surface reaction rate coefficient, k(2), was derived from the flow reactor model. The value of k(2) ranged from 0.68 × 10(-14) cm(4)s(-1)molecule(-1) for α-terpineol adsorbed to PVC to 3.17 × 10(-14) cm(4)s(-1)molecule(-1) for glass, but was insensitive to relative humidity. Further, k(2) is only weakly influenced by the adsorbed mass but instead appears to be more strongly related to the interfacial activity α-terpineol. The minimum reaction probability ranged from 3.79 × 10(-6) for glass at 20% RH to 6.75 × 10(-5) for PVC at 50% RH. The combination of high equilibrium surface coverage and high reactivity for α-terpineol suggests that surface conversion rates are fast enough to compete with or even overwhelm other removal mechanisms in buildings such as gas-phase conversion and air exchange.

  19. Electrical properties of poly(vinyl chloride) films stabilized with ter polymeric photo stabilizers containing UV-absorbing groups

    International Nuclear Information System (INIS)

    Eid, M.A.M.; Rabie, S.T.

    2005-01-01

    Some ter polymeric stabilizers based on polymerizable derivatives of 2,4-dihydroxybenzophenone and phenylsalicylate have been prepared and evaluated as photo stabilizers for rigid PVC. The prepared terpolymers which are namely, methylmethacrylate/2-hydroxyethylmethacrylate/4-methacryloxy- 2-hydroxybenzophenone (MMA/HEMA/HBMA), methylmethacrylate/ 2- Hydroxyethylmethacrylate/ 2-hydroxy-4-(3-methacrylo-xy-2- hydroxypropoxy) benzophenone (MMA/HEMA/PBMA) and methylmethacrylate / 2-Hydroxy-ethyl methacrylate / phenyl-5- methacryloxy methyl salicylate (MMA / HEMA / PMMS) were characterized and their structure were confirmed by GPC, FTIR and UV-VIS spectroscopy. The dielectric study was carried out over a frequency range from 100 Hz to 100 khz at room temperature(22 degree C). The results revealed that the stabilizing effect of these terpolymers depend on the type of stabilizer (terpolymer) and the content of UV absorber units in the terpolymer. The dielectric data for the investigated systems were found to be fitted by two absorption regions using Frohlich function. These regions ascribe the Maxwell.Wagner effect and the intramolecular motion involves the rotation of various segments of the side group as the main chain motion is restricted. The study led to a conclusion that MMA/HEMA/PBMA has the greatest stabilizing efficiency may be due to the relatively longer acrylic side chain in PBMA which makes the molecule more mobile and more flexible

  20. Scientific Results of Conduit Drilling in the Unzen Scientific Drilling Project (USDP

    Directory of Open Access Journals (Sweden)

    Kozo Uto

    2005-09-01

    Full Text Available Abstract Directional drilling at Unzen Volcano in Japan duringmid of 2004 penetrated the magma conduit and successfullyrecovered samples of the lava dike that is believed to havefed the 1991–1995 eruption. The dike was sampled about1.3 km below the volcano’s summit vent and is intrudedinto a broader conduit zone that is 0.5 km wide. This zoneconsists of multiple older lava dikes and pyroclastic veinsand has cooled to less than 200˚C. The lava dike sample wasunexpectedly altered, suggesting that circulation of hydrothermalfluids rapidly cools the conduit region of even veryactive volcanoes. It is likely that seismic signals monitoredprior to emergence of the lava dome reflected fracturing ofthe country rocks, caused by veining as volatiles escapedpredominantly upward, not outward, from the rising magma.Geophysical and geological investigation of cuttings andcore samples from the conduit and of bore-hole logging datacontinues.

  1. Transcatheter Pulmonary Valve Replacement for Right Ventricular Outflow Tract Conduit Dysfunction After the Ross Procedure

    DEFF Research Database (Denmark)

    Gillespie, Matthew J; McElhinney, Doff B; Kreutzer, Jacqueline

    2015-01-01

    BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review of databa......BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review....... Of these, 56 (84%) received a Melody valve; in 5 of the 11 patients who did not, the implant was aborted due to concern for coronary artery compression, and 1 implanted patient required emergent surgery for left coronary compression. The RVOT gradient decreased from a median 38 mm Hg to 13.5 mm Hg (p

  2. Investigation of entrance length in circular and noncircular conduits by computational fluid dynamics simulation

    Directory of Open Access Journals (Sweden)

    Pimpun Tongpun

    2014-08-01

    Full Text Available This study estimated entrance length of circular and noncircular conduits, including circle, triangle, square and hexagon cross-sectional conduit, by using computational fluid dynamics (CFD. For simulation condition, the length of noncircular conduit was 10 m and the hydraulic diameter was 0.2 m. The laminar flow with Reynolds number of 500 and turbulent flow with Reynolds number of 50,000 were applied to investigate water flow in conduits. The governing equations were solved iteratively by using ANSYS FLUENT 14.0. For turbulent flow simulation, standard k-epsilon and RNG k-epsilon model were employed to simulate turbulence. The preliminary results were validated by comparison with theoretical data. At first, grid independency was evaluated to optimize the model. Norm* was employed to investigate the entrance length, which is related to velocity. The simulated results revealed that the entrance length for laminar flow was longer than turbulent flow.

  3. In vivo visualization of microneedle conduits in human skin using laser scanning microscopy

    International Nuclear Information System (INIS)

    Bal, S; Kruithof, A C; Bouwstra, J; Liebl, H; Tomerius, M; Lademann, J; Meinke, M

    2010-01-01

    Solid microneedles enhance the penetration of drugs into the viable skin but little is known about the geometry of the conduits in vivo. Therefore, laser scanning microscopy was used to visualize the conduits of a microneedle system with needles at a length of 300 μm in 6 healthy subjects over a period of time. The model drug, a fluorescent dye was applied before and after piercing. Laser scanning microscopy was evaluated as being an excellent method to monitor the geometry and closure of the conduits over time. The used microneedle system was evaluated as suitable to enhance the transport of model drugs into the viable epidermis without bleeding and a short closure time of the conduits at the skin surface

  4. In vivo visualization of microneedle conduits in human skin using laser scanning microscopy

    Science.gov (United States)

    Bal, S.; Kruithof, A. C.; Liebl, H.; Tomerius, M.; Bouwstra, J.; Lademann, J.; Meinke, M.

    2010-03-01

    Solid microneedles enhance the penetration of drugs into the viable skin but little is known about the geometry of the conduits in vivo. Therefore, laser scanning microscopy was used to visualize the conduits of a microneedle system with needles at a length of 300 μm in 6 healthy subjects over a period of time. The model drug, a fluorescent dye was applied before and after piercing. Laser scanning microscopy was evaluated as being an excellent method to monitor the geometry and closure of the conduits over time. The used microneedle system was evaluated as suitable to enhance the transport of model drugs into the viable epidermis without bleeding and a short closure time of the conduits at the skin surface.

  5. 46 CFR 151.50-34 - Vinyl chloride (vinyl chloride monomer).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Vinyl chloride (vinyl chloride monomer). 151.50-34... chloride (vinyl chloride monomer). (a) Copper, aluminum, magnesium, mercury, silver, and their alloys shall... equipment that may come in contact with vinyl chloride liquid or vapor. (b) Valves, flanges, and pipe...

  6. 21 CFR 184.1297 - Ferric chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ferric chloride. 184.1297 Section 184.1297 Food and... Substances Affirmed as GRAS § 184.1297 Ferric chloride. (a) Ferric chloride (iron (III) chloride, FeC13, CAS Reg. No. 7705-08-0) may be prepared from iron and chlorine or from ferric oxide and hydrogen chloride...

  7. Preparation of pure anhydrous rare earth chlorides

    International Nuclear Information System (INIS)

    Bel'kova, N.L.; Slastenova, N.M.; Batyaev, I.M.; Solov'ev, M.A.

    1979-01-01

    A method has been suggested for obtaining extra-pure anhydrous REE chlorides by chloridizing corresponding oxalates by chlorine in a fluid bed, the chloridizing agents being diluted by an inert gas in a ratio of 2-to-1. The method is applicable to the manufacture of quality chlorides not only of light, but also of heavy REE. Neodymium chloride has an excited life of tau=30 μs, this evidencing the absence of the damping impurities

  8. Silk fibroin enhances peripheral nerve regeneration by improving vascularization within nerve conduits.

    Science.gov (United States)

    Wang, Chunyang; Jia, Yachao; Yang, Weichao; Zhang, Cheng; Zhang, Kuihua; Chai, Yimin

    2018-07-01

    Silk fibroin (SF)-based nerve conduits have been widely used to bridge peripheral nerve defects. Our previous study showed that nerve regeneration in a SF-blended poly (l-lactide-co-ɛ-caprolactone) [P(LLA-CL)] nerve conduit is better than that in a P(LLA-CL) conduit. However, the involved mechanisms remain unclarified. Because angiogenesis within a nerve conduit plays an important role in nerve regeneration, vascularization of SF/P(LLA-CL) and P(LLA-CL) conduits was compared both in vitro and in vivo. In the present study, we observed that SF/P(LLA-CL) nanofibers significantly promoted fibroblast proliferation, and vascular endothelial growth factor secreted by fibroblasts seeded in SF/P(LLA-CL) nanofibers was more than seven-fold higher than that in P(LLA-CL) nanofibers. Conditioned medium of fibroblasts in the SF/P(LLA-CL) group stimulated more human umbilical vein endothelial cells (HUVEC) to form capillary-like networks and promoted faster HUVEC migration. The two kinds of nerve conduits were used to bridge 10-mm-length nerve defects in rats. At 3 weeks of reparation, the blood vessel area in the SF/P(LLA-CL) group was significantly larger than that in the P(LLA-CL) group. More regenerated axons and Schwann cells were also observed in the SF/P(LLA-CL) group, which was consistent with the results of blood vessels. Collectively, our data revealed that the SF/P(LLA-CL) nerve conduit enhances peripheral nerve regeneration by improving angiogenesis within the conduit. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2070-2077, 2018. © 2018 Wiley Periodicals, Inc.

  9. Ureteric catheterization via an ileal conduit: technique and retrieval of a JJ stent.

    Science.gov (United States)

    Wah, T M; Kellett, M J

    2004-11-01

    Retrograde ureteric catheterization of a patient with an ileal conduit is difficult, because guide wires and catheters coil in the conduit. A modified loopogram, using a Foley catheter as a fulcrum through which catheters can be advanced to the ureteric anastomosis, is described. This technique was used to remove a JJ stent, which had been inserted previously across a stricture in one ureter, the stent crossing from one kidney to the other.

  10. Long distance seawater intrusion through a karst conduit network in the Woodville Karst Plain, Florida

    OpenAIRE

    Zexuan Xu; Seth Willis Bassett; Bill Hu; Scott Barrett Dyer

    2016-01-01

    Five periods of increased electrical conductivity have been found in the karst conduits supplying one of the largest first magnitude springs in Florida with water. Numerous well-developed conduit networks are distributed in the Woodville Karst Plain (WKP), Florida and connected to the Gulf of Mexico. A composite analysis of precipitation and electrical conductivity data provides strong evidence that the increases in conductivity are directly tied to seawater intrusion moving inland and travel...

  11. Generation of Complex Karstic Conduit Networks with a Hydro-chemical Model

    Science.gov (United States)

    De Rooij, R.; Graham, W. D.

    2016-12-01

    The discrete-continuum approach is very well suited to simulate flow and solute transport within karst aquifers. Using this approach, discrete one-dimensional conduits are embedded within a three-dimensional continuum representative of the porous limestone matrix. Typically, however, little is known about the geometry of the karstic conduit network. As such the discrete-continuum approach is rarely used for practical applications. It may be argued, however, that the uncertainty associated with the geometry of the network could be handled by modeling an ensemble of possible karst conduit networks within a stochastic framework. We propose to generate stochastically realistic karst conduit networks by simulating the widening of conduits as caused by the dissolution of limestone over geological relevant timescales. We illustrate that advanced numerical techniques permit to solve the non-linear and coupled hydro-chemical processes efficiently, such that relatively large and complex networks can be generated in acceptable time frames. Instead of specifying flow boundary conditions on conduit cells to recharge the network as is typically done in classical speleogenesis models, we specify an effective rainfall rate over the land surface and let model physics determine the amount of water entering the network. This is advantageous since the amount of water entering the network is extremely difficult to reconstruct, whereas the effective rainfall rate may be quantified using paleoclimatic data. Furthermore, we show that poorly known flow conditions may be constrained by requiring a realistic flow field. Using our speleogenesis model we have investigated factors that influence the geometry of simulated conduit networks. We illustrate that our model generates typical branchwork, network and anastomotic conduit systems. Flow, solute transport and water ages in karst aquifers are simulated using a few illustrative networks.

  12. Polyvinyl alcohol coating of polystyrene inertial confinement fusion targets

    International Nuclear Information System (INIS)

    Annamalai, P.; Lee, M.C.; Crawley, R.L.; Downs, R.L.

    1985-01-01

    An inertial confinement fusion (ICF) target made of polystyrene is first levitated in an acoustic field. The surface of the target is then etched using an appropriate solution (e.g., cyclohexane) to enhance the wetting characteristics. A specially prepared polyvinyl alcohol solution is atomized using an acoustic atomizer and deposited on the surface of the target. The solution is air dried to form a thin coating (2 μm) on the target (outside diameter approx.350--850 μm). Thicker coatings are obtained by repeated applications of the coating solution. Preliminary results indicate that uniform coatings may be achievable on the targets with a background surface smoothness in the order of 1000 A

  13. Polypyrrole-polyvinyl sulphonate film based disposable nucleic acid biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakar, Nirmal [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India); Centre for Biomedical Engineering, Indian Institute of Technology, Hauz Khas, New Delhi 110016 (India); Arora, Kavita [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India); Singh, Surinder P. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India); Pandey, Manoj K. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India); Singh, Harpal [Centre for Biomedical Engineering, Indian Institute of Technology, Hauz Khas, New Delhi 110016 (India); Malhotra, Bansi D. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India)]. E-mail: bansi.malhotra@gmail.com

    2007-04-18

    Double stranded calf thymus deoxyribonucleic acid entrapped polypyrrole-polyvinyl sulphonate (dsCT-DNA-PPy-PVS) films fabricated onto indium-tin-oxide (ITO) coated glass plates have been used to detect organophosphates such as chlorpyrifos and malathion. These disposable dsCT-DNA-PPy-PVS/ITO bioelectrodes have been characterized using cyclic voltammetry, Fourier-transform-infra-red (FTIR) spectroscopy and atomic force microscopy (AFM), respectively. These biosensing electrodes have a response time of 30 s, are stable for about 5 months when stored in desiccated conditions at 25 deg. C and can be used to amperometrically detect chlorpyrifos (0.0016-0.025 ppm) and malathion (0.17-5.0), respectively. The additive effect of these pesticides on the amperometric response of the disposable dsCT-DNA-PPy-PVS/ITO bioelectrodes has also been investigated.

  14. Effect of gamma radiation on the poly(vinyl alcohol)

    International Nuclear Information System (INIS)

    Terence, M.C.; Guedes, S.M.L.

    2000-01-01

    The poly(vinyl alcohol) (PVAL) is a polymer used as bio material. The PVAL was used as ocular insert and may be used as a drug delivery system (DDS) for pair PVAL/gancyclovir, where the last one is used for treatment of people with retinitis caused by cytomegalovirus. These inserts are crosslinked systems. The crosslink was induced by gamma radiation applied in polymer. The samples of PVAL was irradiated by gamma rays with doses in the range 0 to 100 kGy. On irradiated PVAL samples was observed a low yellowness, attributed to the formation of polymeric radicals that are stable in the structure of the polymer, from radiolysis of PVAL. (author)

  15. Dancing on coke: smuggling cocaine dispersed in polyvinyl alcohol.

    Science.gov (United States)

    van Nuijs, Alexander L N; Maudens, Kristof E; Lambert, Willy E; Van Calenbergh, Serge; Risseeuw, Martijn D P; Van hee, Paul; Covaci, Adrian; Neels, Hugo

    2012-01-01

    Recent trends suggest that cocaine smugglers have become more and more inventive to avoid seizures of large amounts of cocaine transported between countries. We report a case of a mail parcel containing a dance pad which was seized at the Customs Department of Brussels Airport, Belgium. After investigation, the inside of the dance pad was found to contain a thick polymer, which tested positive for cocaine. Analysis was performed using a routine colorimetric swipe test, gas chromatography coupled with mass spectrometry and nuclear magnetic resonance spectroscopy. The polymer was identified as polyvinyl alcohol (PVA) and contained 18% cocaine, corresponding to a street value of € 20,000. Laboratory experiments showed that cocaine could be easily extracted from the PVA matrix. This case report reveals a new smuggling technique for the transportation of large amounts of cocaine from one country to another. © 2011 American Academy of Forensic Sciences.

  16. Preparation and characterization of bioglass/polyvinyl alcohol composite hydrogel

    International Nuclear Information System (INIS)

    Xu Hong; Wang Yingjun; Zheng Yudong; Chen Xiaofeng; Ren Li; Wu Gang; Huang Xiaoshan

    2007-01-01

    In order to form firm active fixation with the adjacent bone, a new kind of bioactive composite hydrogel was prepared with polyvinyl alcohol (PVA) and bioglass (BG) through ultrasonic dispersion, heat-high-pressure and freeze/thawed technique. A digital speckle correlation method (DSCM) was utilized to characterize the mechanical properties of the series of BG/PVA composites. Results showed that at different load pressures, the composite hydrogel displayed different displacement and deformation in the V field. Results also showed that an increase of PVA percentage (15-30 wt%) or of bioglass percentage (2-10 wt%) in composite hydrogel could lead to an increase in the elastic compression modulus. Scanning electron microscope results indicated that bioglass was uniformly dispersed in the BG/PVA composite hydrogel. The BG/PVA composite hydrogel shows a promising prospect as a new bionic cartilage implantation material

  17. Reentrant behaviour in polyvinyl alcohol-borax hydrogels

    Science.gov (United States)

    Lawrence, Mathias B.; Desa, J. A. E.; Aswal, V. K.

    2018-01-01

    Polyvinyl alcohol (PVA) hydrogels, cross-linked with varying concentrations of borax, were studied with small angle neutron scattering (SANS), x-ray diffraction (XRD) and differential thermal analysis (DTA). The SANS data satisfy the Ornstein-Zernike approximation. The hydrogels are modelled as PVA chains bound by borate cross-links. Water occupies the spaces within the three-dimensional hydrogel network. The mesh size ξ indicates reentrant behaviour i.e. at first, ξ increases and later decreases as a function of borax concentration. The behaviour is explained on the basis of the balance between the charged di-diol cross-links and the shielding by free ions in the solvent. XRD and DTA show the molecular size of water in the solvent and the glass transition temperature commensurate with reentrant behaviour.

  18. MR and CT imaging of pulmonary valved conduits in children and adolescents: normal appearance and complications

    Energy Technology Data Exchange (ETDEWEB)

    Tenisch, Estelle V.; Alamo, Leonor T.; Gudinchet, Francois [Lausanne University Hospital, Department of Medical Imaging, Lausanne (Switzerland); Sekarski, Nicole [Lausanne University Hospital, Department of Pediatrics, Lausanne (Switzerland); Hurni, Michel [Lausanne University Hospital, Department of Cardiovascular Surgery, Lausanne (Switzerland)

    2014-12-15

    The Contegra registered is a conduit made from the bovine jugular vein and then interposed between the right ventricle and the pulmonary artery. It is used for cardiac malformations in the reconstruction of right ventricular outflow tract. To describe both normal and pathological appearances of the Contegra registered in radiological imaging, to describe imaging of complications and to define the role of CT and MRI in postoperative follow-up. Forty-three examinations of 24 patients (17 boys and 7 girls; mean age: 10.8 years old) with Contegra registered conduits were reviewed. Anatomical description and measurements of the conduits were performed. Pathological items examined included stenosis, dilatation, plicature or twist, thrombus or vegetations, calcifications and valvular regurgitation. Findings were correlated to the echographic gradient through the conduit when available. CT and MR work-up showed Contegra registered stenosis (n = 12), dilatation (n = 9) and plicature or twist (n = 7). CT displayed thrombus or vegetations in the Contegra registered in three clinically infected patients. Calcifications of the conduit were present at CT in 12 patients and valvular regurgitation in three patients. The comparison between CT and/or MR results showed a good correlation between the echographic gradient and the presence of stenosis in the Contegra registered. CT and MR bring additional information about permeability and postoperative anatomy especially when echocardiography is inconclusive. Both techniques depict the normal appearance of the conduit, and allow comparison and precise evaluation of changes in the postoperative follow-up. (orig.)

  19. In vitro evaluation of carbon-nanotube-reinforced bioprintable vascular conduits

    International Nuclear Information System (INIS)

    Dolati, Farzaneh; Yu, Yin; Zhang, Yahui; Ozbolat, Ibrahim T; Jesus, Aribet M De; Sander, Edward A

    2014-01-01

    Vascularization of thick engineered tissue and organ constructs like the heart, liver, pancreas or kidney remains a major challenge in tissue engineering. Vascularization is needed to supply oxygen and nutrients and remove waste in living tissues and organs through a network that should possess high perfusion ability and significant mechanical strength and elasticity. In this paper, we introduce a fabrication process to print vascular conduits directly, where conduits were reinforced with carbon nanotubes (CNTs) to enhance their mechanical properties and bioprintability. In vitro evaluation of printed conduits encapsulated in human coronary artery smooth muscle cells was performed to characterize the effects of CNT reinforcement on the mechanical, perfusion and biological performance of the conduits. Perfusion and permeability, cell viability, extracellular matrix formation and tissue histology were assessed and discussed, and it was concluded that CNT-reinforced vascular conduits provided a foundation for mechanically appealing constructs where CNTs could be replaced with natural protein nanofibers for further integration of these conduits in large-scale tissue fabrication. (paper)

  20. A biosynthetic nerve guide conduit based on silk/SWNT/fibronectin nanocomposite for peripheral nerve regeneration.

    Directory of Open Access Journals (Sweden)

    Fatemeh Mottaghitalab

    Full Text Available As a contribution to the functionality of nerve guide conduits (NGCs in nerve tissue engineering, here we report a conduit processing technique through introduction and evaluation of topographical, physical and chemical cues. Porous structure of NGCs based on freeze-dried silk/single walled carbon nanotubes (SF/SWNTs has shown a uniform chemical and physical structure with suitable electrical conductivity. Moreover, fibronectin (FN containing nanofibers within the structure of SF/SWNT conduits produced through electrospinning process have shown aligned fashion with appropriate porosity and diameter. Moreover, fibronectin remained its bioactivity and influenced the adhesion and growth of U373 cell lines. The conduits were then implanted to 10 mm left sciatic nerve defects in rats. The histological assessment has shown that nerve regeneration has taken places in proximal region of implanted nerve after 5 weeks following surgery. Furthermore, nerve conduction velocities (NCV and more myelinated axons were observed in SF/SWNT and SF/SWNT/FN groups after 5 weeks post implantation, indicating a functional recovery for the injured nerves. With immunohistochemistry, the higher S-100 expression of Schwann cells in SF/SWNT/FN conduits in comparison to other groups was confirmed. In conclusion, an oriented conduit of biocompatible SF/SWNT/FN has been fabricated with acceptable structure that is particularly applicable in nerve grafts.

  1. Colorful and transparent poly(vinyl alcohol) composite films filled with layered zinc hydroxide salts, intercalated with anionic orange azo dyes (methyl orange and orange II)

    International Nuclear Information System (INIS)

    Neves da Silva, Marlon Luiz; Marangoni, Rafael; Cursino, Ana Cristina Trindade; Schreiner, Wido Herwig; Wypych, Fernando

    2012-01-01

    Highlights: ► Zinc hydroxide salts were successfully intercalated with anionic orange azo dyes. ► The anionic dye was co-intercalated with hydrated chloride anions. ► The orange materials were used as fillers for poly(vinyl alcohol). ► Transparent, homogeneous, colorful PVA films were obtained by wet casting. ► Some composites stored at lower humidity exhibited improved mechanical properties. - Abstract: Layered zinc hydroxide salts (zinc LHS) were intercalated with anionic orange azo dyes, namely methyl orange (MO) and orange II (OII), and co-intercalated with hydrated chloride anions. After characterization by X-ray diffraction (XRD), thermal analysis (TGA/DTA), Fourier transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS), the materials were used as fillers for poly(vinyl alcohol) (PVA). Colorful transparent films were obtained by wet casting, revealing good dispersion of the material into the polymer. In the case of zinc LHS/OII, PVA was intercalated between the zinc LHS layers. Evaluation of the mechanical properties of the PVA composite films revealed that the layered colorful materials were able to increase the mechanical properties of the PVA films only when the films were stored under lower relative humidity. As expected, films with higher water content displayed reduced tensile strength and modulus because of the plasticizing effect of water. As for the films stored at 43% relative humidity, more pronounced improvement of modulus was observed for 1 and 4% zinc LHS/OII, and enhanced tensile strength was achieved for 0.5 and 1% zinc LHS/OII. This effect can be attributed to better dispersion of the layered filler and its better adhesion to the PVA matrix.

  2. Reaction of calcium chloride with alkali metal chlorides in melts

    International Nuclear Information System (INIS)

    Savin, V.D.; Mikhajlova, N.P.

    1984-01-01

    Thermochemical characteristics of CaCl 2 reaction with sodium, potassium, rubidium and cesium chlorides in melts at 890 deg C are determined. The values of formation enthalpies of infinitely diluted by CaCl 2 solutions (ΔH) in the chloride row increase from -22 in NaCl to -47 kJ/mol of CaCl 2 in CsCl. With increasing the concentration of calcium chloride in the solution the ΔH values decrease. The regularities of separation from the solution of the CaCl 2 -CsCl system at 890 deg C of the CaCl 2 x CsCl in solid are studied. Formation enthalpies under the given conditions constitutes -70+-3 kJ/mol

  3. The Himalayas: barrier and conduit for gene flow.

    Science.gov (United States)

    Gayden, Tenzin; Perez, Annabel; Persad, Patrice J; Bukhari, Areej; Chennakrishnaiah, Shilpa; Simms, Tanya; Maloney, Trisha; Rodriguez, Kristina; Herrera, Rene J

    2013-06-01

    The Himalayan mountain range is strategically located at the crossroads of the major cultural centers in Asia, the Middle East and Europe. Although previous Y-chromosome studies indicate that the Himalayas served as a natural barrier for gene flow from the south to the Tibetan plateau, this region is believed to have played an important role as a corridor for human migrations between East and West Eurasia along the ancient Silk Road. To evaluate the effects of the Himalayan mountain range in shaping the maternal lineages of populations residing on either side of the cordillera, we analyzed mitochondrial DNA variation in 344 samples from three Nepalese collections (Newar, Kathmandu and Tamang) and a general population of Tibet. Our results revealed a predominantly East Asian-specific component in Tibet and Tamang, whereas Newar and Kathmandu are both characterized by a combination of East and South Central Asian lineages. Interestingly, Newar and Kathmandu harbor several deep-rooted Indian lineages, including M2, R5, and U2, whose coalescent times from this study (U2, >40 kya) and previous reports (M2 and R5, >50 kya) suggest that Nepal was inhabited during the initial peopling of South Central Asia. Comparisons with our previous Y-chromosome data indicate sex-biased migrations in Tamang and a founder effect and/or genetic drift in Tamang and Newar. Altogether, our results confirm that while the Himalayas acted as a geographic barrier for human movement from the Indian subcontinent to the Tibetan highland, it also served as a conduit for gene flow between Central and East Asia. Copyright © 2013 Wiley Periodicals, Inc.

  4. Current distribution in Cable-In-Conduit Conductors

    International Nuclear Information System (INIS)

    Ferri, M.A.

    1994-05-01

    A numerical study of the current distribution in Cable-In-Conduit Conductors (CICC's) experiencing linearly ramping transport currents and transverse magnetic fields was conducted for both infinitely long, periodic cables and finite length cables terminated in low resistance joints. The goal of the study was to gain insight into the phenomenon known as Ramp Rate Limitation, an as yet unexplained correspondence between maximum attainable current and the ramp time taken to reach that current in CICC superconducting magnets. A discrete geometric model of a 27 strand multiply twisted CICC was developed to effectively represent the flux linkages, mutual inductances, and resistive contact points between the strands of an experimentally tested cable. The results of the numerical study showed that for fully periodic cables, the current imbalances due to ramping magnetic fields and ramping transport currents are negligible in the range of experimentally explored operating conditions. For finite length, joint terminated cables, however, significant imbalances can exist. Unfortunately, quantitative results are limited by a lack of knowledge of the transverse resistance between strands in the joints. Nonetheless, general results are presented showing the dependency of the imbalance on cable length, ramp time, and joint resistance for both ramping transverse magnet fields and ramping transport currents. At the conclusion of the study, it is suggested that calculated current imbalances in a finite length cable could cause certain strands to prematurely ''quench'' -- become non-superconducting --thus leading to an instability for the entire cable. This numerically predicted ''current imbalance instability'' is compared to the experimentally observed Ramp Rate Limitation for the 27 strand CICC sample

  5. Conduits to care: call lights and patients’ perceptions of communication

    Directory of Open Access Journals (Sweden)

    Montie M

    2017-09-01

    Full Text Available Mary Montie,1 Clayton Shuman,1 Jose Galinato,1 Lance Patak,2 Christine A Anderson,1 Marita G Titler1 1Department of Systems, Populations, and Leadership, School of Nursing, University of Michigan, Ann Arbor, MI, 2Department of Anesthesiology and Pain Medicine, Seattle Children’s Hospital, Seattle, WA, USA Background: Call light systems remain the primary means of hospitalized patients to initiate communication with their health care providers. Although there is vast amounts of literature discussing patient communication with their health care providers, few studies have explored patients’ perceptions concerning call light use and communication. The specific aim of this study was to solicit patients’ perceptions regarding their call light use and communication with nursing staff. Methods: Patients invited to this study met the following inclusion criteria: proficient in English, been hospitalized for at least 24 hours, aged ≥21 years, and able to communicate verbally (eg, not intubated. Thirty participants provided written informed consent, were enrolled in the study, and completed interviews. Results: Using qualitative descriptive methods, five major themes emerged from patients’ perceptions (namely; establishing connectivity, participant safety concerns, no separation: health care and the call light device, issues with the current call light, and participants’ perceptions of “nurse work”. Multiple minor themes supported these major themes. Data analysis utilized the constant comparative methods of Glaser and Strauss. Discussion: Findings from this study extend the knowledge of patients’ understanding of not only why inconsistencies occur between the call light and their nurses, but also why the call light is more than merely a device to initiate communication; rather, it is a direct conduit to their health care and its delivery. Keywords: nurse–patient communication, medical technology, quality of care, qualitative research

  6. A polymer foam conduit seeded with Schwann cells promotes guided peripheral nerve regeneration.

    Science.gov (United States)

    Hadlock, T; Sundback, C; Hunter, D; Cheney, M; Vacanti, J P

    2000-04-01

    Alternatives to autografts have long been sought for use in bridging neural gaps. Many entubulation materials have been studied, although with generally disappointing results in comparison with autografts. The purpose of this study was to design a more effective neural guidance conduit, to introduce Schwann cells into the conduit, and to determine regenerative capability through it in an in vivo model. A novel, fully biodegradable polymer conduit was designed and fabricated for use in peripheral nerve repair, which approximates the macro- and microarchitecture of native peripheral nerves. It comprised a series of longitudinally aligned channels, with diameters ranging from 60 to 550 microns. The lumenal surfaces promoted the adherence of Schwann cells, whose presence is known to play a key role in nerve regeneration. This unique channel architecture increased the surface area available for Schwann cell adherence up to five-fold over that available through a simple hollow conduit. The conduit was composed of a high-molecular-weight copolymer of lactic and glycolic acids (PLGA) (MW 130,000) in an 85:15 monomer ratio. A novel foam-processing technique, employing low-pressure injection molding, was used to create highly porous conduits (approximately 90% pore volume) with continuous longitudinal channels. Using this technique, conduits were constructed containing 1, 5, 16, 45, or more longitudinally aligned channels. Prior to cellular seeding of these conduits, the foams were prewet with 50% ethanol, flushed with physiologic saline, and coated with laminin solution (10 microg/mL). A Schwann cell suspension was dynamically introduced into these processed foams at a concentration of 5 X 10(5) cells/mL, using a simple bioreactor flow loop. In vivo regeneration studies were carried out in which cell-laden five-channel polymer conduits (individual channel ID 500 microm, total conduit OD 2.3 mm) were implanted across a 7-mm gap in the rat sciatic nerve (n = 4), and midgraft

  7. Electrochemical Chloride extraction using external electrodes?

    DEFF Research Database (Denmark)

    Ottosen, Lisbeth M.; Pedersen, Anne Juul

    2006-01-01

    Electrochemical methods for the removal of chloride from concrete have been developed and the methods are primarily designed for situations where corrosion has started due to an increased chloride concentration in the vicinity of the reinforcement. In these methods the reinforcement is used...... as the cathode. However, some unwanted side effects can occur, including alkali-silica reaction and in some cases hydrogen embrittlement. It is also suggested also to use electrochemical chloride extraction in a preventive way in constructions where chloride induced corrosion is likely to be a problem after...... a period of time, i.e. remove the chlorides before the chloride front reaches the reinforcement. If the chlorides are removed from outer few centimetres from the surface, the chloride will not reach the reinforcement and cause damage. By using the electrochemical chloride removal in this preventive way...

  8. Performance properties and antibacterial activity of crosslinked films of quaternary ammonium modified starch and poly(vinyl alcohol).

    Science.gov (United States)

    Sekhavat Pour, Zahra; Makvandi, Pooyan; Ghaemy, Mousa

    2015-09-01

    There has been a growing interest in developing antibacterial polymeric materials. In the present work, novel antibacterial cross-linked blend films were prepared based on polyvinyl alcohol (PVA) and quaternary ammonium starch (ST-GTMAC) using citric acid (CA) as plasticizer and glutaraldehyde (GA) as cross-linker. The ST-GTMAC was successfully synthesized from reaction between water-soluble oxidized starch and glycidyltrimethylammonium chloride (GTMAC). The effect of ST-GTMAC, CA and GA contents on the swelling, solubility, mechanical and thermal properties of the films was investigated. It was found that incorporation of ST-GTMAC reduced UV-transmittance and provided antibacterial properties, increasing GA content increased tensile strength and decreased solubility and swelling degree of the films, while CA acted as plasticizer when its concentration was above 10 wt%. The results showed that ST-GTMAC/PVA/CA/GA film has fair antibacterial activity against Gram-positive (Staphylococcus aureus and Bacillus subtilis) and Gram-negative (Escherichia coli and Pseudomonas aeruginosa) bacteria. These results suggest that the prepared film might be used as potential antibacterial material in medical and packaging applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Heterogeneous electro-Fenton catalyst for 1-butylpyridinium chloride degradation.

    Science.gov (United States)

    Meijide, Jessica; Pazos, Marta; Sanromán, Maria Ángeles

    2017-10-15

    The application of the electro-Fenton process for organic compound mineralisation has been widely reported over the past years. However, operational problems related to the use of soluble iron salt as a homogeneous catalyst involve the development of novel catalysts that are able to operate in a wide pH range. For this purpose, polyvinyl alcohol-alginate beads, containing goethite as iron, were synthesised and evaluated as heterogeneous electro-Fenton catalyst for 1-butylpyridinium chloride mineralisation. The influence of catalyst dosage and pH solution on ionic liquid degradation was analysed, achieving almost total oxidation after 60 min under optimal conditions (2 g/L catalyst concentration and pH 3). The results showed good catalyst stability and reusability, although its effectiveness decreases slightly after three successive cycles. Furthermore, a plausible mineralisation pathway was proposed based on the oxidation byproducts determined by chromatographic techniques. Finally, the Microtox® test revealed notable detoxification after treatment which demonstrates high catalyst ability for pyridinium-based ionic liquid degradation by the electro-Fenton process.

  10. Properties of poly(vinyl alcohol)–borax gel doped with neodymium ...

    Indian Academy of Sciences (India)

    visible region then leads to luminescent emission in the near infra-red region. The spectral qualities of the ... molecular hydrogen bonding between the hydroxyl groups on poly(vinyl ..... mately results in near IR emissions. The maximum of the.

  11. 78 FR 20890 - Polyvinyl Alcohol From Taiwan: Preliminary Results of Antidumping Duty Administrative Review...

    Science.gov (United States)

    2013-04-08

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-583-841] Polyvinyl Alcohol From... Administration, International Trade Administration, Department of Commerce. SUMMARY: The Department of Commerce..., AD/CVD Operations, Office 1, Import Administration, International Trade Administration, U.S...

  12. Fabrication and Optimization of Gelatin/ Nano Bioglass Conduits for Peripheral Nerve Regeneration

    Directory of Open Access Journals (Sweden)

    M. Foroutan Koudehi

    2014-07-01

    Full Text Available Introduction & Objective: Peripheral nerve injury is common in trauma patients and 4.5% of all soft-tissue injuries are accompanied by defects of peripheral nerve. Peripheral nerve injuries can lead to lifetime loss of function and permanent disfigurement. Designed conduits com-prised of natural and synthetic materials are now widely used in the construction of damaged tissues. The aim of this project was to prepare nanocomposite conduits from gelatin and bioglass for damaged peripheral nerve reconstruction. Materials & Methods: In this experimental study,compound water solution of gelatin and nano bioglass synthesized through sol gel method, was made. After preparing the solution, special mandrels were dipped in solution several times and freeze dried in order to be emptied of wa-ter via sublimation. The conduits had the following dimensions: internal diameter: 1.6 mm, outside diameter: 2.2 mm and length about 12 mm. In order to evaluate the biocompatibility of conduits we used cytotoxicity test by Chinese ovary cells and MTT assay by Miapaca-2 (pancreatic cancer cell line. Results: The prepared nano bioglass and conduits were characterized using transmission elec-tron microscopy, scanning electron microscopy, fourier transformed infrared spectroscopy and X-ray diffraction. Results of biocompatibility test showed no sign of cytotoxicity and cells were found to be attached to the pore walls offered by the conduits. Conclusion: According to the results, nano bioglass conduits could be a good candidate for peripheral nerve regeneration. (Sci J Hamadan Univ Med Sci 2014; 21 (2:152-160

  13. Polymeric Nerve Conduits with Contact Guidance Cues Used in Nerve Repair

    Institute of Scientific and Technical Information of China (English)

    G DAI; X NIU; J YIN

    2016-01-01

    In the modern life, the nerve injury frequently happens due to mechanical, chemical or thermal accidents. In the trivial injuries, the peripheral nerves can regenerate on their own; however, in most of the cases the clinical treatments are required, where relatively large nerve injury gaps are formed. Currently, the nerve repair can be accomplished by direct suture when the injury gap is not too large;while the autologous nerve graft working as the gold standard of peripheral nerve injury treatment for nerve injuries with larger gaps. However, the direct suture is limited by heavy tension at the suture sites, and the autologous nerve graft also has the drawbacks of donor site morbidity and insufifcient donor tissue. Recently, artiifcial nerve conduits have been developed as an alternative for clinical nerve repair to overcome the limitations associated with the above treatments. In order to further improve the efifciency of nerve conduits, various guidance cues are incorporated, including physical cues, biochemical signals, as well as support cells. First, this paper reviewed the contact guidance cues applied in nerve conduits, such as lumen ifllers, multi-channels and micro-patterns on the inner surface. Then, the paper focused on the polymeric nerve conduits with micro inner grooves. The polymeric nerve conduits were fabricated using the phase inversion-based ifber spinning techniques. The smart spinneret with grooved die was designed in the spinning platform, while different spinning conditions, including flow rates, air-gap distances, and polymer concentrations, were adjusted to investigate the inlfuence of fabrication conditions on the geometry of nerve conduits. The inner groove size in the nerve conduits can be precisely controlled in our hollow ifber spinning process, which can work as the efifcient contact guidance cue for nerve regeneration.

  14. Sorption of water vapor in partially hydrolyzed poly(vinyl acetate)

    International Nuclear Information System (INIS)

    Spencer, H.G.; Honeycutt, S.C.

    1973-01-01

    The sorption kinetics of H 2 O and D 2 O in copolymers of partially hydrolyzed poly(vinyl acetate) were studied and compared with the sorption kinetics of vinyl acetate--vinyl alcohol copolymers, and poly(vinyl alcohol). The special measurement problems presented by transient-state sorption studies in water vapor--polymer systems and their effects on the results are discussed

  15. Compatibility of butorphanol and droperidol in 0.9% sodium chloride injection.

    Science.gov (United States)

    Chen, Fu-Chao; Fang, Bao-Xia; Li, Peng; Yang, Jin-Guo; Zhou, Ben-Hong

    2013-03-15

    The compatibility and stability of butorphanol tartrate and droperidol in polyvinyl chloride (PVC) bags and glass bottles stored at 4°C and 25°C for up to 15 days were studied. Admixtures were assessed initially and for 15 days after preparation in PVC bags and glass bottles using 0.9% sodium chloride injection as a diluent and stored at 4°C and 25°C. The initial drug concentrations were 0.08 mg/mL for butorphanol tartrate and 0.05 mg/mL for droperidol. Samples were withdrawn from each container immediately after preparation and at predetermined intervals (2, 4, 8, 24, 48, 72, 120, 168, 240, and 360 hours after preparation). The solutions were visually inspected for precipitation, cloudiness, and discoloration at each sampling interval. Drug concentrations were determined using a validated high-pressure liquid chromatography method. After 15 days of storage, all formulations tested retained >98% of the initial concentrations of both drugs. The drug mixtures were clear in appearance, and no color change or precipitation was observed. Throughout this period, pH values remained stable. Admixtures of butorphanol tartrate 0.08 mg/mL and droperidol 0.05 mg/mL in 0.9% sodium chloride injection were stable for at least 360 hours when stored in PVC bags or glass bottles at 4°C and 25°C and protected from light.

  16. Visualization of conduit-matrix conductivity differences in a karst aquifer using time-lapse electrical resistivity

    Science.gov (United States)

    Meyerhoff, Steven B.; Karaoulis, Marios; Fiebig, Florian; Maxwell, Reed M.; Revil, André; Martin, Jonathan B.; Graham, Wendy D.

    2012-12-01

    In the karstic upper Floridan aquifer, surface water flows into conduits of the groundwater system and may exchange with water in the aquifer matrix. This exchange has been hypothesized to occur based on differences in discharge at the Santa Fe River Sink-Rise system, north central Florida, but has yet to be visualized using any geophysical techniques. Using electrical resistivity tomography, we conducted a time-lapse study at two locations with mapped conduits connecting the Santa Fe River Sink to the Santa Fe River Rise to study changes of electrical conductivity during times of varying discharge over a six-week period. Our results show conductivity differences between matrix, conduit changes in resistivity occurring through time at the locations of mapped karst conduits, and changes in electrical conductivity during rainfall infiltration. These observations provide insight into time scales and matrix conduit conductivity differences, illustrating how surface water flow recharged to conduits may flow in a groundwater system in a karst aquifer.

  17. Rhenium corrosion in chloride melts

    International Nuclear Information System (INIS)

    Stepanov, A.D.; Shkol'nikov, S.N.; Vetyukov, M.M.

    1989-01-01

    The results investigating rhenium corrosion in chloride melts containing sodium, potassium and chromium ions by a gravimetry potentials in argon atmosphere in a sealing quarth cell are described. Rhenium corrosion is shown to be rather considerable in melts containing CrCl 2 . The value of corrosion rate depending on temperature is determined

  18. Elicitation threshold of cobalt chloride

    DEFF Research Database (Denmark)

    Fischer, Louise A; Johansen, Jeanne D; Voelund, Aage

    2016-01-01

    : On the basis of five included studies, the ED10 values of aqueous cobalt chloride ranged between 0.0663 and 1.95 µg cobalt/cm(2), corresponding to 30.8-259 ppm. CONCLUSIONS: Our analysis provides an overview of the doses of cobalt that are required to elicit allergic cobalt contactdermatitis in sensitized...

  19. Structures and lithofacies of inferred silicic conduits in the Paraná-Etendeka LIP, southernmost Brazil

    Science.gov (United States)

    Simões, M. S.; Lima, E. F.; Sommer, C. A.; Rossetti, L. M. M.

    2018-04-01

    Extensive silicic units in the Paraná-Etendeka LIP have been long interpreted as pyroclastic density currents (rheomorphic ignimbrites) derived from the Messum Complex in Namibia. In recent literature, however, they have been characterized as effusive lava flows and domes. In this paper we describe structures and lithofacies related to postulated silicic lava feeder conduits at Mato Perso, São Marcos and Jaquirana-Cambará do Sul areas in southern Brazil. Inferred conduits are at least 15-25 m in width and the lithofacies include variably vesicular monomictic welded and non-welded breccias in the margins to poorly vesicular, banded, spherulitic and microfractured vitrophyres in the central parts. Flat-lying coherent vitrophyres and massive obsidian are considered to be the subaerial equivalents of the conduits. Large-scale, regional tectonic structures in southern Brazil include the NE-SW aligned Porto Alegre Suture, Leão and Açotea faults besides the Antas Lineament, a curved tectonic feature accompanying the bed of Antas river. South of the Antas Lineament smaller-scale, NW-SE lineaments limit the exposure areas of the inferred conduits. NE-SW and subordinate NW-SE structures within this smaller-scale lineaments are represented by the main postulated conduit outcrops and are parallel to the dominant sub-vertical banding in the widespread banded vitrophyre lithofacies. Upper lava flows display flat-lying foliation, pipe-like and spherical vesicles and have better developed microlites. Petrographic characteristics of the silicic vitrophyres indicate that crystal-poor magmas underwent distinct cooling paths for each inferred conduit area. The vitrophyre chemical composition is defined by the evolution of trachydacitic/dacitic vitrophyres with 62-65 wt% SiO2 to rhyodacite and rhyolite with 66-68 wt% SiO2. The more evolved rocks are assigned to the latest intrusive grey vitrophyre outcropping in the center of the conduits. Degassing pathways formed during

  20. Investigation of physico-mechanical properties of flexible poly (vinyl chloride) filled with antimony trioxide using ionizing radiation.

    Science.gov (United States)

    Elnaggar, Mona Y; Fathy, E S; Hassan, Medhat M

    2018-04-12

    Composites of polyvinyl chloride (PVC) with 2% calcium carbonate, 2% diethyl phthalate, 2% paraffin wax and 2% lead sulphate and different contents of antimony trioxide (Sb 2 O 3 ) prepared by melting and irradiated with gamma ray have been considered. Assessment of the mechanical and thermal properties of the unirradiated and irradiated flexible polyvinyl chloride (FPVC) were completed utilizing elasticity (TS), Elongation at break (Eb) and thermogravimetric analysis measurements. TS and thermal stability of FPVC displayed advanced improvement after addition of additives and this approach highlighted the efficiency of those ingredients on PVC. The compounding of FPVC with Sb 2 O 3 in various extents was examined by FTIR, X-ray diffraction and scanning electron microscope methods. It is obvious that the presence of Sb 2 O 3 begins impacting oxidative degradation, leading to a decrease in mechanical properties up to 10%. Moreover, a slight increase in the thermal stability of composites by exposure to ionizing radiation is apparently due to cross-linking of FPVC chains.

  1. Surface Chloride Levels in Colorado Structural Concrete

    Science.gov (United States)

    2018-01-01

    This project focused on the chloride-induced corrosion of reinforcing steel in structural concrete. The primary goal of this project is to analyze the surface chloride concentration level of the concrete bridge decks throughout Colorado. The study in...

  2. Pharmacokinetics of vinyl chloride in the rat

    International Nuclear Information System (INIS)

    Bolt, H.M.; Laib, R.J.; Kappus, H.; Buchter, A.

    1977-01-01

    When rats are exposed to [ 14 C]vinyl chloride in a closed system, the vinyl chloride present in the atmosphere equilibrates with the animals' organism within 15 min. The course of equilibration could be determined using rats which had been given 6-nitro-1,2,3-benzothiadiazole. This compound completely blocks metabolism of vinyl chloride. The enzymes responsible for metabolism of vinyl chloride are saturated at an atmospheric concentration of vinyl chloride of 250 ppm. Pharmacokinetic analysis shows that no significant cumulation of vinyl chloride or its major metabolites is to be expected on repeated administration of vinyl chlorides. This may be consistent with the theory that a reactive, shortly living metabolite which occurs in low concentration only, may be responsible for the toxic effects of vinyl chloride

  3. Uncovering Offshore Financial Centers: Conduits and Sinks in the Global Corporate Ownership Network.

    Science.gov (United States)

    Garcia-Bernardo, Javier; Fichtner, Jan; Takes, Frank W; Heemskerk, Eelke M

    2017-07-24

    Multinational corporations use highly complex structures of parents and subsidiaries to organize their operations and ownership. Offshore Financial Centers (OFCs) facilitate these structures through low taxation and lenient regulation, but are increasingly under scrutiny, for instance for enabling tax avoidance. Therefore, the identification of OFC jurisdictions has become a politicized and contested issue. We introduce a novel data-driven approach for identifying OFCs based on the global corporate ownership network, in which over 98 million firms (nodes) are connected through 71 million ownership relations. This granular firm-level network data uniquely allows identifying both sink-OFCs and conduit-OFCs. Sink-OFCs attract and retain foreign capital while conduit-OFCs are attractive intermediate destinations in the routing of international investments and enable the transfer of capital without taxation. We identify 24 sink-OFCs. In addition, a small set of five countries - the Netherlands, the United Kingdom, Ireland, Singapore and Switzerland - canalize the majority of corporate offshore investment as conduit-OFCs. Each conduit jurisdiction is specialized in a geographical area and there is significant specialization based on industrial sectors. Against the idea of OFCs as exotic small islands that cannot be regulated, we show that many sink and conduit-OFCs are highly developed countries.

  4. Small-sized conduits in the right ventricular outflow tract in young children: bicuspidalized homografts are a good alternative to standard conduits.

    Science.gov (United States)

    François, Katrien; De Groote, Katya; Vandekerckhove, Kristof; De Wilde, Hans; De Wolf, Daniel; Bové, Thierry

    2017-10-03

    Downsizing a homograft (HG) through bicuspidalization has been used for more than 2 decades to overcome the shortage of small-sized conduits for reconstruction of the right ventricular outflow tract (RVOT) in young children. Our goal was to investigate the durability of bicuspidalized HGs compared with other small HGs. A retrospective analysis of 93 conduits ≤20 mm, implanted over 23 years, was performed. The end-points were survival, structural valve degeneration and conduit replacement. The conduits comprised 40 pulmonary HGs, 12 aortic HGs, 17 bicuspidalized HGs and 24 xenografts. The median age, mean conduit diameter and z-value at implantation were 1.4 (interquartile range 0.3-3) years, 16.5 ± 2.7 mm and 2.8 ± 1.3, respectively. Valve position was heterotopic in 59 patients and orthotopic in 34 patients. At a mean follow-up period of 7.6 ± 5.9 years, the hospital survival rate was 89%. Freedom from explant at 5 and 10 years was 83 ± 5% and 52 ± 6%, respectively. Freedom from structural valve degeneration was 79 ± 5% at 5 years and 47 ± 6% at 10 years [68 ± 8% for pulmonary HG, 42 ± 16% for bicuspidalized HG, 31 ± 15% for aortic HG and 20 ± 9% for xenografts (log rank P right ventricular outflow tract conduit in young children. However, when a small pulmonary HG is unavailable, bicuspidalization offers a valid alternative, preferable to xenograft conduits, at mid-term follow-up. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. 21 CFR 184.1193 - Calcium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Calcium chloride. 184.1193 Section 184.1193 Food... Specific Substances Affirmed as GRAS § 184.1193 Calcium chloride. (a) Calcium chloride (CaCl2·2H2O, CAS Reg. No. 10035-04-8) or anhydrous calcium chloride (CaCl2, CAS Reg. No. 10043-52-4) may be commercially...

  6. Microbial reductive dehalogenation of vinyl chloride

    Science.gov (United States)

    Spormann, Alfred M [Stanford, CA; Muller, Jochen A [Baltimore, MD; Rosner, Bettina M [Berlin, DE; Von Abendroth, Gregory [Nannhein, DE; Meshulam-Simon, Galit [Los Altos, CA; McCarty, Perry L [Stanford, CA

    2011-11-22

    Compositions and methods are provided that relate to the bioremediation of chlorinated ethenes, particularly the bioremediation of vinyl chloride by Dehalococcoides-like organisms. An isolated strain of bacteria, Dehalococcoides sp. strain VS, that metabolizes vinyl chloride is provided; the genetic sequence of the enzyme responsible for vinyl chloride dehalogenation; methods of assessing the capability of endogenous organisms at an environmental site to metabolize vinyl chloride; and a method of using the strains of the invention for bioremediation.

  7. Graft copolymerization of styrene onto poly(vinyl alcohol) initiated by potassium diperiodatocuprate (III)

    International Nuclear Information System (INIS)

    Bai, L.; Wang, Ch.; Jin, J.; Liu, Y.

    2009-01-01

    The graft copolymerization of styrene onto poly(vinyl alcohol) is studied by using a novel redox system of potassium diperiodatocuprate-poly(vinyl alcohol) (Cu(III)poly(vinyl alcohol) in alkaline medium. Cu(III)-poly(vinyl alcohol) redox pair is an efficient initiator for this graft copolymerization which is proved by high graft efficiency (>97%) and high percentage of graft (>300%). Reaction conditions (monomer-to-poly(vinyl alcohol) weight ratio, initiator concentration, p H, time and temperature) affect the graft parameters which have been investigated systematically. The optimum reaction conditions are found as St/poly(vinyl alcohol) = 5.4; [Cu(III)] = 1*10 -2 M; p H = 12.7; temperature = 50 d eg C ; time = 3.5 h. Further, the equation of the overall polymerization rate can be written as follows: R p = k C 1.9 (St) C 1.7 (Cu(III)). The overall activation energy was calculated to be 42.0 kJ/mol based on the experimental data of the relations between R p and C(St); R p and C(Cu(III)); and R p and temperature. A mechanism is proposed to explain the formation of radicals and the initiation. The structure of the graft copolymers is confirmed by Fourier transfer infrared spectroscopy. Some peaks were compared with poly(vinyl alcohol) at 3080.34-3001.79 cm -1 (=C-H stretching in the phenyl ring), 1600.34-1450.95 cm -1 (C=C stretching in the phenyl ring), 755.17 cm -1 and 698.64 cm -1 (=C-H out-off-plane bending in phenyl ring) which are considered to belong to the characteristic absorption bands of phenyl group of polystyrene. Therefore it proves that the graft copolymer is composed of poly(vinyl alcohol) and polystyrene. thermal gravimetric analysis thermo grams of poly(vinyl alcohol) and poly(vinyl alcohol)-graft-polystyrene are investigated as well. As it is shown the initial decomposition temperature of poly(vinyl alcohol)-g-polystyrene(377.3 d eg C ) is much higher than that of poly(vinyl alcohol) (241.8 d eg C ), which indicates that the thermal stability of the

  8. Optical and structural behaviors of crosslinked polyvinyl alcohol thin films

    Science.gov (United States)

    Pandit, Subhankar; Kundu, Sarathi

    2018-04-01

    Polyvinyl Alcohol (PVA) has excellent properties like uniaxial tensile stress, chemical resistance, biocompatibility, etc. The properties of PVA further can be tuned by crosslinking process. In this work, a simple heat treatment method is used to find out the optimum crosslinking of PVA and the corresponding structural and optical responses are explored. The PVA crosslinking is done by exposing the films at different temperatures and time intervals. The optical property of pure and heat treated PVA films are investigated by UV-Vis absorption and photoluminescence emission spectroscopy and structural modifications are studied by Fourier Transform Infrared Spectroscopy (FTIR). The absorption peaks of pure PVA are observed at ≈ 280 and 335 nm and the corresponding emission is observed at ≈ 424 nm. The pure PVA showed modified optical behaviors after the heat treatment. In addition, dipping the PVA films in hot water (85°C) for nearly 20 minutes also show impact on both structural and optical properties. From FTIR spectroscopy, the changes in vibrational band positions confirm the structural modifications of PVA films.

  9. Modification of polyvinyl alcohol surface properties by ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Pukhova, I.V., E-mail: ivpuhova@mail.ru [National Research Tomsk State University, 36 Lenin Ave, Tomsk 634050 (Russian Federation); Institute of High Current Electronics, 2/3 Akademichesky Ave, Tomsk 634055 (Russian Federation); Kurzina, I.A. [National Research Tomsk State University, 36 Lenin Ave, Tomsk 634050 (Russian Federation); Savkin, K.P. [Institute of High Current Electronics, 2/3 Akademichesky Ave, Tomsk 634055 (Russian Federation); Laput, O.A. [National Research Tomsk Polytechnic University, 30 Lenin Ave, Tomsk 634050 (Russian Federation); Oks, E.M. [Institute of High Current Electronics, 2/3 Akademichesky Ave, Tomsk 634055 (Russian Federation)

    2017-05-15

    We describe our investigations of the surface physicochemical properties of polyvinyl alcohol modified by silver, argon and carbon ion implantation to doses of 1 × 10{sup 14}, 1 × 10{sup 15} and 1 × 10{sup 16} ion/cm{sup 2} and energies of 20 keV (for C and Ar) and 40 keV (for Ag). Infrared spectroscopy (IRS) indicates that destructive processes accompanied by chemical bond (−C=O) generation are induced by implantation, and X-ray photoelectron spectroscopy (XPS) analysis indicates that the implanted silver is in a metallic Ag3d state without stable chemical bond formation with polymer chains. Ion implantation is found to affect the surface energy: the polar component increases while the dispersion part decreases with increasing implantation dose. Surface roughness is greater after ion implantation and the hydrophobicity increases with increasing dose, for all ion species. We find that ion implantation of Ag, Ar and C leads to a reduction in the polymer microhardness by a factor of five, while the surface electrical resistivity declines modestly.

  10. UV-responsive polyvinyl alcohol nanofibers prepared by electrospinning

    Energy Technology Data Exchange (ETDEWEB)

    Khatri, Zeeshan, E-mail: zeeshan.khatri@faculty.muet.edu.pk [Department of Textile Engineering, Mehran University of Engineering and Technology, Jamshoro 76062 (Pakistan); Nano Fusion Technology Research Lab, Division of Frontier Fibers, Institute for Fiber Engineering (IFES), Interdisciplinary Cluster for Cutting Edge Research (ICCER), Shinshu University, 3-15-1, Tokida, Ueda, Nagano 386-8567 (Japan); Ali, Shamshad [Department of Textile Engineering, Mehran University of Engineering and Technology, Jamshoro 76062 (Pakistan); Department of Organic and Nano Engineering, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Khatri, Imran [Department of Entomology, Sindh Agriculture University, Tandojam (Pakistan); Mayakrishnan, Gopiraman [Nano Fusion Technology Research Lab, Division of Frontier Fibers, Institute for Fiber Engineering (IFES), Interdisciplinary Cluster for Cutting Edge Research (ICCER), Shinshu University, 3-15-1, Tokida, Ueda, Nagano 386-8567 (Japan); Kim, Seong Hun [Department of Organic and Nano Engineering, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Kim, Ick-Soo, E-mail: kim@shinshu-u.ac.jp [Nano Fusion Technology Research Lab, Division of Frontier Fibers, Institute for Fiber Engineering (IFES), Interdisciplinary Cluster for Cutting Edge Research (ICCER), Shinshu University, 3-15-1, Tokida, Ueda, Nagano 386-8567 (Japan)

    2015-07-01

    Graphical abstract: - Highlights: • UV responsive PVA nanofibers were prepared via electrospinning. • Quick response codes were recorded multiple times on UV responsive nanofibers. • The rate of photo-coloration was found faster than the rate of photo-reversibility. - Abstract: We report UV-responsive polyvinyl alcohol (PVA) nanofibers for potential application for recording and erasing quick response (QR) codes. We incorporate 1′-3′-dihydro-8-methoxy-1′,3′,3′-trimethyl-6-nitrospiro [2H-1-benzopyran-2,2′-(2H)-indole] (indole) and,3-dihydro-1,3,3-trimethylspiro [2H-indole-2,3′-[3H] phenanthr [9,10-b] (1,4) oxazine] (oxazine) into PVA polymer matrix via electrospinning technique. The resultant nanofibers were measured for recording–erasing, photo-coloration and thermal reversibility. The rate of photo-coloration of PVA–indole nanofibers was five times higher than the PVA–oxazine nanofibers, whereas the thermal reversibility found to be more than twice as fast as PVA–oxazine nanofibers. Results showed that the resultant nanofibers have very good capability of recording QR codes multiple times. The FTIR spectroscopy and SEM were employed to characterize the electrospun nanofibers. The UV-responsive PVA nanofibers have great potentials as a light-driven nanomaterials incorporated within sensors, sensitive displays and in optical devices such as erasable and rewritable optical storage.

  11. Development of hydroxyapatite/polyvinyl alcohol bionanocomposite for prosthesis implants

    Science.gov (United States)

    Karthik, V.; Pabi, S. K.; Chowdhury, S. K. Roy

    2018-02-01

    Hydroxyapatite (Ca10(PO4)6(OH)2) has similar structural and chemical properties of natural bone mineral and hence widely used as a bone replacement substitute. Natural bone consists of hydroxyapatite and collagen. For mimicking the natural, in the present work, a sintered porous hydroxyapatite component has been vacuum impregnated with Polyvinyl alcohol (PVA), which has better properties like biocompatibility, biodegradability and water- solubility. Hydroxyapatite powders have been made into nanosize to reduce the melting point and hence the sintering temperature. In the present investigation high energy ball mill is used to produce nano-hydroxyapatite powders in bulk quantity by optimizing the milling parameters using stainless steel grinding media. Pellets of 10 mm diameter have been produced from nano- hydroxyapatite powders under different uniaxial compaction pressures. The pellets have been sintered to form porous compacts. The vacuum impregnation of sintered pallets with PVA solution of different strength has been done to find the optimum impregnation condition. Microhardness, compressive strength, wear loss and haemocompatibility of hydroxyapatite ceramics have been studied before and after impregnation of PVA. The nano- hydroxyapatite/PVA composites have superior mechanical properties and reduced wear loss than the non-impregnated porous nano-hydroxyapatite ceramics.

  12. Artificial Auricular Cartilage Using Silk Fibroin and Polyvinyl Alcohol Hydrogel

    Science.gov (United States)

    Lee, Jung Min; Sultan, Md. Tipu; Kim, Soon Hee; Kumar, Vijay; Yeon, Yeung Kyu; Lee, Ok Joo; Park, Chan Hum

    2017-01-01

    Several methods for auricular cartilage engineering use tissue engineering techniques. However, an ideal method for engineering auricular cartilage has not been reported. To address this issue, we developed a strategy to engineer auricular cartilage using silk fibroin (SF) and polyvinyl alcohol (PVA) hydrogel. We constructed different hydrogels with various ratios of SF and PVA by using salt leaching, silicone mold casting, and freeze-thawing methods. We characterized each of the hydrogels in terms of the swelling ratio, tensile strength, pore size, thermal properties, morphologies, and chemical properties. Based on the cell viability results, we found a blended hydrogel composed of 50% PVA and 50% SF (P50/S50) to be the best hydrogel among the fabricated hydrogels. An intact 3D ear-shaped auricular cartilage formed six weeks after the subcutaneous implantation of a chondrocyte-seeded 3D ear-shaped P50/S50 hydrogel in rats. We observed mature cartilage with a typical lacunar structure both in vitro and in vivo via histological analysis. This study may have potential applications in auricular tissue engineering with a human ear-shaped hydrogel. PMID:28777314

  13. Thermal stability of polyvinyl alcohol/nanocrystalline cellulose composites.

    Science.gov (United States)

    Voronova, Marina I; Surov, Oleg V; Guseinov, Sabir S; Barannikov, Vladimir P; Zakharov, Anatoly G

    2015-10-05

    Thermal stability of polyvinyl alcohol/cellulose nanocrystals (PVA/CNCs) composites prepared with solution casting technique was studied. The PVA/CNCs composites were characterized by Fourier transform infrared spectrometry, X-ray diffraction, differential scanning calorimeter (DSC) and thermogravimetric (TG) analysis. Due to the presence of CNCs nanoparticles, thermal degradation of the composites occurs at much higher temperatures compared to that of the neat PVA. Thermal stability of the PVA/CNCs composites is maximally enhanced with CNCs content of 8-12 wt%. Some thermal degradation products of the PVA/CNCs composites were identified by mass spectrometric analysis. TG measurements with synchronous recording of mass spectra revealed that the thermal degradation of both CNCs and PVA in the composites with CNCs content of 8-12 wt% occurs simultaneously at a much higher temperature than that of CNCs or the neat PVA. However, with increasing CNCs content more than 12 wt% the thermal stability of the composites decreases. In this case, the degradation of CNCs comes first followed by the degradation of PVA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Adsorption Characteristics of Polyvinyl Alcohols in Solution on Expanded Graphite

    Directory of Open Access Journals (Sweden)

    Xiu-Yan Pang

    2012-01-01

    Full Text Available Expanded graphite (EG adsorbent was prepared with 50 mesh graphite as raw materials, potassium permanganate as oxidant, and vitriol as intercalation compound. Three kinds of polyvinyl alcohol (PVA with different degree of polymerization (DP in aqueous solution were used as adsorbates. We have studied the influence of initial PVA concentration, temperature and ionic strength on adsorption capacity. Langmuir constants and Gibbs free energy change (⊿G° were calculated according to experimental data respectively. Thermodynamic analysis indicates the equilibrium adsorbance of PVA on EG increase with the rise of SO42– concentration. Adsorption isotherms of PVA with different degree of polymerization are all types and we deduce PVA molecules lie flat on EG surface. Adsorption processes are all spontaneous. Kinetic studies show that the kinetic data can be described by pseudo second-order kinetic model. Second-order rate constants and the initial adsorption rate rise with the increasing of temperature and half-adsorption time decreases with the increasing of temperature. The adsorption activation energy of each PVA is less than 20 kJ•mol−1, physical adsorption is the major mode of the overall adsorption process.

  15. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited.

    Science.gov (United States)

    Xia, Wenfeng; Piras, Daniele; Heijblom, Michelle; Steenbergen, Wiendelt; van Leeuwen, Ton G; Manohar, Srirang

    2011-07-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F-T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where temperature distributions during F-T are relatively homogeneous. In this work, in breast-sized samples we observed substantial temperature differences between the shallow regions and the interior during the F-T procedure. We investigated whether spatial variations were also present in the acoustic and optical properties. The speed of sound, acoustic attenuation, and optical reduced scattering coefficients were measured on specimens sampled at various locations in a large phantom. In general, the properties matched values quoted for breast tissue. But while acoustic properties were relatively homogeneous, the reduced scattering was substantially different at the surface compared with the interior. We correlated these variations with gel microstructure inspected using scanning electron microscopy. Interestingly, the phantom's reduced scattering spatial distribution matches the optical properties of the standard two-layer breast model used in x ray dosimetry. We conclude that large PVA samples prepared using the standard recipe make excellent breast tissue phantoms.

  16. UV-responsive polyvinyl alcohol nanofibers prepared by electrospinning

    International Nuclear Information System (INIS)

    Khatri, Zeeshan; Ali, Shamshad; Khatri, Imran; Mayakrishnan, Gopiraman; Kim, Seong Hun; Kim, Ick-Soo

    2015-01-01

    Graphical abstract: - Highlights: • UV responsive PVA nanofibers were prepared via electrospinning. • Quick response codes were recorded multiple times on UV responsive nanofibers. • The rate of photo-coloration was found faster than the rate of photo-reversibility. - Abstract: We report UV-responsive polyvinyl alcohol (PVA) nanofibers for potential application for recording and erasing quick response (QR) codes. We incorporate 1′-3′-dihydro-8-methoxy-1′,3′,3′-trimethyl-6-nitrospiro [2H-1-benzopyran-2,2′-(2H)-indole] (indole) and,3-dihydro-1,3,3-trimethylspiro [2H-indole-2,3′-[3H] phenanthr [9,10-b] (1,4) oxazine] (oxazine) into PVA polymer matrix via electrospinning technique. The resultant nanofibers were measured for recording–erasing, photo-coloration and thermal reversibility. The rate of photo-coloration of PVA–indole nanofibers was five times higher than the PVA–oxazine nanofibers, whereas the thermal reversibility found to be more than twice as fast as PVA–oxazine nanofibers. Results showed that the resultant nanofibers have very good capability of recording QR codes multiple times. The FTIR spectroscopy and SEM were employed to characterize the electrospun nanofibers. The UV-responsive PVA nanofibers have great potentials as a light-driven nanomaterials incorporated within sensors, sensitive displays and in optical devices such as erasable and rewritable optical storage

  17. Time domain NMR evaluation of poly(vinyl alcohol) xerogels

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Elton Jorge da Rocha; Cavalcante, Maxwell de Paula; Tavares, Maria Ines Bruno, E-mail: mibt@ima.ufrj.br [Universidade Federal do Rio de Janeiro (IMA/UFRJ), Rio de Janeiro, RJ (Brazil). Centro de Tecnologia. Instituto de Macromoleculas Professora Eloisa Mano

    2016-05-15

    Poly(vinyl alcohol) (PVA)-based chemically cross-linked xerogels, both neat and loaded with nanoparticulate hydrophilic silica (SiO{sub 2}), were obtained and characterized mainly through time domain NMR experiments (TD-NMR). Fourier-transform infrared (FT-IR) and wide angle X-ray diffraction (WAXD) analyses were employed as secondary methods. TD-NMR, through the interpretation of the spin-lattice relaxation constant values and related information, showed both cross-linking and nanoparticle influences on PVA matrix. SiO{sub 2} does not interact chemically with the PVA chains, but has effect on its molecular mobility, as investigated via TD-NMR. Apparent energy of activation, spin-lattice time constant and size of spin domains in the sample have almost linear dependence with the degree of cross-linking of the PVA and are affected by the addition of SiO{sub 2}. These three parameters were derived from a single set of TD-NMR experiments, which demonstrates the versatility of the technique for characterization of inorganic-organic hybrid xerogels, an important class of materials. (author)

  18. Research progress of fabricating polyvinyl alcohol coating on plastic microsphere

    International Nuclear Information System (INIS)

    Su Lin; Chen Sufen; Liu Meifang; Zhang Zhanwen; Yao Hong; Li Bo; Liu Yiyang

    2012-01-01

    In the procedures of designing polystyrene-polyvinyl alcohol-CH (carbon and hydrogen elements) (PS-PVA-CH) triple-layer microspheres, there are many methods such as drop-tower technique, emulsion micro-encapsulation, dip (spin) coating, interfacial polycondensation, and spraying technique to prepare the PVA coating. Drop-tower technique, emulsion micro-encapsulation and dip (spin) coating are most-commonly used. The advantages, disadvantages and the research progress of the three methods are summarized in this paper. Emulsion micro-encapsulation is suitable for preparing double-layer microspheres of sizes smaller then 500 μm, with high survival ratio and good quality. However, the preparation process is easily influenced by artificial factors. Small-sized double-layer microspheres can also be prepared by the drop-tower technique, and the preparation period is short. But there are still some problems such as the difficulty in designing the droplet generator, uneven PVA coating and the difficulty in preparing large-sized microspheres. Dip (spin) coating technique can be used to prepare PS-PVA microspheres with sizes larger than 1000 μm, but the spread of PVA coating is affected by many factors in this method, and the prepared PVA coating is too thin and not uniform. (authors)

  19. 21 CFR 173.255 - Methylene chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Methylene chloride. 173.255 Section 173.255 Food... Solvents, Lubricants, Release Agents and Related Substances § 173.255 Methylene chloride. Methylene chloride may be present in food under the following conditions: (a) In spice oleoresins as a residue from...

  20. 21 CFR 182.8252 - Choline chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Choline chloride. 182.8252 Section 182.8252 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR... chloride. (a) Product. Choline chloride. (b) Conditions of use. This substance is generally recognized as...

  1. 21 CFR 184.1446 - Manganese chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Manganese chloride. 184.1446 Section 184.1446 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR... Specific Substances Affirmed as GRAS § 184.1446 Manganese chloride. (a) Manganese chloride (MnCl2·4H2O, CAS...

  2. 21 CFR 582.5985 - Zinc chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Zinc chloride. 582.5985 Section 582.5985 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS... 1 § 582.5985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions of use. This substance is...

  3. 21 CFR 582.3845 - Stannous chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Stannous chloride. 582.3845 Section 582.3845 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL....3845 Stannous chloride. (a) Product. Stannous chloride. (b) Tolerance. This substance is generally...

  4. 21 CFR 582.6193 - Calcium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Calcium chloride. 582.6193 Section 582.6193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance is generally...

  5. 21 CFR 582.5446 - Manganese chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Manganese chloride. 582.5446 Section 582.5446 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5446 Manganese chloride. (a) Product. Manganese chloride. (b) Conditions of use. This...

  6. 21 CFR 182.8985 - Zinc chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Zinc chloride. 182.8985 Section 182.8985 Food and... CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions of use. This substance is generally recognized as safe when used in...

  7. 21 CFR 172.180 - Stannous chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Stannous chloride. 172.180 Section 172.180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... Preservatives § 172.180 Stannous chloride. The food additive stannous chloride may be safely used for color...

  8. 49 CFR 173.322 - Ethyl chloride.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Ethyl chloride. 173.322 Section 173.322 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.322 Ethyl chloride. Ethyl chloride must be...

  9. 21 CFR 582.5252 - Choline chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Choline chloride. 582.5252 Section 582.5252 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5252 Choline chloride. (a) Product. Choline chloride. (b) Conditions of use. This...

  10. 21 CFR 582.5622 - Potassium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Potassium chloride. 582.5622 Section 582.5622 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5622 Potassium chloride. (a) Product. Potassium chloride. (b) Conditions of use. This...

  11. 21 CFR 582.1193 - Calcium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Calcium chloride. 582.1193 Section 582.1193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Additives § 582.1193 Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance...

  12. 7 CFR 58.434 - Calcium chloride.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Calcium chloride. 58.434 Section 58.434 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... Material § 58.434 Calcium chloride. Calcium chloride, when used, shall meet the requirements of the Food...

  13. 21 CFR 173.400 - Dimethyldialkylammonium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Dimethyldialkylammonium chloride. 173.400 Section... HUMAN CONSUMPTION Specific Usage Additives § 173.400 Dimethyldialkylammonium chloride. Dimethyldialkylammonium chloride may be safely used in food in accordance with the following prescribed conditions: (a...

  14. Shallow conduit processes of the 1991 Hekla eruption, Iceland

    Science.gov (United States)

    Gudnason, J.; Thordarson, T.; Houghton, B. F.

    2013-12-01

    On January 17, 1991 at 17:00 hrs, the 17th eruption of Hekla since 1104AD began. Lasting for almost two months, it produced 0.02 km3 of icelandite tephra and ~0.15km3 of icelandite lava. This eruption was the third of four eruptions since 1980 with a recurrence period of approximately 10 years, as opposed to a recurrence interval of c. 55 years for the eruptions in the period 1104AD to 1947AD. [1] The last four Hekla eruptions are typified by a 0.5-2 hour-long initial phase of subplinian intensity and discharge ranging from 2900-6700 m3/s [2]. In all 4 events the inital phase was followed by a sustained and relatively low-discharge(sorted tephra fall covering >20,000 km2. Here we examine the first phase of the Hekla 1991 eruption with focus on vesiculation and fragmentation processes in the shallow conduit and ash production. Samples of the tephra fall were collected on snow immediately after the initial phase at multiple sites providing a representative spatial coverage within the 0.1mm isopach [3]. This set was augmented by samples collected in 2012 to provide tighter coverage of near vent region. Grain size of all samples has been measured down to 1 micron. Density measurements have been conducted on 4 near-vent pumice samples (100 clasts each) and the pumice vesicle size distribution has been determined in a selected subset of clasts. The reconstructed whole deposit grain size distribution exhibits a unimodal, log-normal distribution peaking at -3 phi, typical of dry, magmatic fragmentation. Pumice densities range from 520-880 kg/m3 and exhibit a tight unimodal and log-normal distribution indicating a mean vesicularity of 77% to 79% for the magma erupted during the initial phase. Along with preliminary results for bubble number density and vesicle size distribution this implies a single late-stage homogeneous bubble nucleation and very uniform conditions of magma fragmentation during this short-lived initial phase of the Hekla 1991 eruption. 1. Gudmundsson, A

  15. The Use of Degradable Nerve Conduits for Human Nerve Repair: A Review of the Literature

    Directory of Open Access Journals (Sweden)

    M. F. Meek

    2005-01-01

    Full Text Available The management of peripheral nerve injury continues to be a major clinical challenge. The most widely used technique for bridging defects in peripheral nerves is the use of autologous nerve grafts. This technique, however, has some disadvantages. Many alternative experimental techniques have thus been developed, such as degradable nerve conduits. Degradable nerve guides have been extensively studied in animal experimental studies. However, the repair of human nerves by degradable nerve conduits has been limited to only a few clinical studies. In this paper, an overview of the available international published literature on degradable nerve conduits for bridging human peripheral nerve defects is presented for literature available until 2004. Also, the philosophy on the use of nerve guides and nerve grafts is given.

  16. Transverse colon conduit urinary diversion in patients treated with very high dose pelvic irradiation

    International Nuclear Information System (INIS)

    Ravi, R.; Dewan, A.K.; Pandey, K.K.

    1994-01-01

    Urinary diversion may be required in patients receiving pelvic irradiation for gynaecological or genitourinary cancers either as part of a planned or salvage surgical procedure or for urological complications of irradiation. Records were reviewed for 30 such patients who underwent transverse colon conduit as a primary form of urinary diversion. Most of the conduits were constructed using refluxing ureterocolic anastomoses with stents. The results showed no operative mortality. Although the procedure was associated with a complication rate of 37% and a re-operation rate of 20%, there were no bowel or urinary anastomotic leaks. The operation could be safely performed on patients with renal failure, with 83% of such patients showing normal or improved serum creatinine levels post operatively. The advantages of transverse colon conduit urinary diversion are the use of non-irradiated bowel and ureters for diversion. It is recommended as a primary form of urinary diversion in these high risk cases. (Author)

  17. Collagen-coated polylactic-glycolic acid (PLGA) seeded with neural-differentiated human mesenchymal stem cells as a potential nerve conduit.

    Science.gov (United States)

    Sulong, Ahmad Fadzli; Hassan, Nur Hidayah; Hwei, Ng Min; Lokanathan, Yogeswaran; Naicker, Amaramalar Selvi; Abdullah, Shalimar; Yusof, Mohd Reusmaazran; Htwe, Ohnmar; Idrus, Ruszymah Bt Hj; Haflah, Nor Hazla Mohamed

    2014-01-01

    Autologous nerve grafts to bridge nerve gaps pose various drawbacks. Nerve tissue engineering to promote nerve regeneration using artificial neural conduits has emerged as a promising alternative. To develop an artificial nerve conduit using collagen-coated polylactic-glycolic acid (PLGA) and to analyse the survivability and propagating ability of the neuro-differentiated human mesenchymal stem cells in this conduit. The PLGA conduit was constructed by dip-molding method and coated with collagen by immersing the conduit in collagen bath. The ultra structure of the conduits were examined before they were seeded with neural-differentiated human mesenchymal stem cells (nMSC) and implanted sub-muscularly on nude mice thighs. The non-collagen-coated PLGA conduit seeded with nMSC and non-seeded non-collagen-coated PLGA conduit were also implanted for comparison purposes. The survivability and propagation ability of nMSC was studied by histological and immunohistochemical analysis. The collagen-coated conduits had a smooth inner wall and a highly porous outer wall. Conduits coated with collagen and seeded with nMSCs produced the most number of cells after 3 weeks. The best conduit based on the number of cells contained within it after 3 weeks was the collagen-coated PLGA conduit seeded with neuro-transdifferentiated cells. The collagen-coated PLGA conduit found to be suitable for attachment, survival and proliferation of the nMSC. Minimal cell infiltration was found in the implanted conduits where nearly all of the cells found in the cell seeded conduits are non-mouse origin and have neural cell markers, which exhibit the biocompatibility of the conduits. The collagen-coated PLGA conduit is biocompatible, non-cytotoxic and suitable for use as artificial nerve conduits.

  18. Genipin-Cross-Linked Chitosan Nerve Conduits Containing TNF-α Inhibitors for Peripheral Nerve Repair.

    Science.gov (United States)

    Zhang, Li; Zhao, Weijia; Niu, Changmei; Zhou, Yujie; Shi, Haiyan; Wang, Yalin; Yang, Yumin; Tang, Xin

    2018-07-01

    Tissue engineered nerve grafts (TENGs) are considered a promising alternative to autologous nerve grafting, which is considered the "gold standard" clinical strategy for peripheral nerve repair. Here, we immobilized tumor necrosis factor-α (TNF-α) inhibitors onto a nerve conduit, which was introduced into a chitosan (CS) matrix scaffold utilizing genipin (GP) as the crosslinking agent, to fabricate CS-GP-TNF-α inhibitor nerve conduits. The in vitro release kinetics of TNF-α inhibitors from the CS-GP-TNF-α inhibitor nerve conduits were investigated using high-performance liquid chromatography. The in vivo continuous release profile of the TNF-α inhibitors released from the CS-GP-TNF-α inhibitor nerve conduits was measured using an enzyme-linked immunosorbent assay over 14 days. We found that the amount of TNF-α inhibitors released decreased with time after the bridging of the sciatic nerve defects in rats. Moreover, 4 and 12 weeks after surgery, histological analyses and functional evaluations were carried out to assess the influence of the TENG on regeneration. Immunochemistry performed 4 weeks after grafting to assess early regeneration outcomes revealed that the TENG strikingly promoted axonal outgrowth. Twelve weeks after grafting, the TENG accelerated myelin sheath formation, as well as functional restoration. In general, the regenerative outcomes following TENG more closely paralleled findings observed with autologous grafting than the use of the CS matrix scaffold. Collectively, our data indicate that the CS-GP-TNF-α inhibitor nerve conduits comprised an elaborate system for sustained release of TNF-α inhibitors in vitro, while studies in vivo demonstrated that the TENG could accelerate regenerating axonal outgrowth and functional restoration. The introduction of CS-GP-TNF-α-inhibitor nerve conduits into a scaffold may contribute to an efficient and adaptive immune microenvironment that can be used to facilitate peripheral nerve repair.

  19. FDG-PET identification of infected pulmonary artery conduit following tetralogy of fallot (TOF) repair

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yu Yang; Williams, Hadyn; Pucar, Darko [Dept. of Radiology, Medical College of Georgia, Augusta (United States)

    2017-03-15

    Tetralogy of Fallot (TOF) is one of the most common forms of cyanotic congenital heart disease usually managed by serial surgical repairs. The repaired prosthetic valve or conduit is susceptible to life-threatening infection. FDG-PET is an effective alternative to evaluate the source of infection when other examinations are inconclusive. We report an unusual case of an infected pulmonary artery conduit after TOF repair although the echocardiogram was negative for vegetation, which was later confirmed by surgery and pathology. The case highlights the role of FDG-PET as a problem-solving tool for potential endocarditis and cardiac device infection cases after complex cardiac surgery.

  20. The grain-size distribution of pyroclasts: Primary fragmentation, conduit sorting or abrasion?

    Science.gov (United States)

    Kueppers, U.; Schauroth, J.; Taddeucci, J.

    2013-12-01

    Explosive volcanic eruptions expel a mixture of pyroclasts and lithics. Pyroclasts, fragments of the juvenile magma, record the state of the magma at fragmentation in terms of porosity and crystallinity. The grain size distribution of pyroclasts is generally considered to be a direct consequence of the conditions at magma fragmentation that is mainly driven by gas overpressure in bubbles, high shear rates, contact with external water or a combination of these factors. Stress exerted by any of these processes will lead to brittle fragmentation by overcoming the magma's relaxation timescale. As a consequence, most pyroclasts exhibit angular shapes. Upon magma fragmentation, the gas pyroclast mixture is accelerated upwards and eventually ejected from the vent. The total grain size distribution deposited is a function of fragmentation conditions and transport related sorting. Porous pyroclasts are very susceptible to abrasion by particle-particle or particle-conduit wall interaction. Accordingly, pyroclastic fall deposits with angular clasts should proof a low particle abrasion upon contact to other surfaces. In an attempt to constrain the degree of particle interaction during conduit flow, monomodal batches of washed pyroclasts have been accelerated upwards by rapid decompression and subsequently investigated for their grain size distribution. In our set-up, we used a vertical cylindrical tube without surface roughness as conduit. We varied grain size (0.125-0.25; 0.5-1; 1-2 mm), porosity (0; 10; 30 %), gas-particle ratio (10 and 40%), conduit length (10 and 28 cm) and conduit diameter (2.5 and 6 cm). All ejected particles were collected after settling at the base of a 3.3 m high tank and sieved at one sieve size below starting size (half-Φ). Grain size reduction showed a positive correlation with starting grain size, porosity and overpressure at the vent. Although milling in a volcanic conduit may take place, porous pyroclasts are very likely to be a primary product

  1. Havery Mudd 2014-2015 Computer Science Conduit Clinic Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Aspesi, G [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bai, J [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Deese, R [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shin, L [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-12

    Conduit, a new open-source library developed at Lawrence Livermore National Laboratories, provides a C++ application programming interface (API) to describe and access scientific data. Conduit’s primary use is for inmemory data exchange in high performance computing (HPC) applications. Our team tested and improved Conduit to make it more appealing to potential adopters in the HPC community. We extended Conduit’s capabilities by prototyping four libraries: one for parallel communication using MPI, one for I/O functionality, one for aggregating performance data, and one for data visualization.

  2. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.

    Science.gov (United States)

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-02-07

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.

  3. FDG-PET identification of infected pulmonary artery conduit following tetralogy of fallot (TOF) repair

    International Nuclear Information System (INIS)

    Zhang, Yu Yang; Williams, Hadyn; Pucar, Darko

    2017-01-01

    Tetralogy of Fallot (TOF) is one of the most common forms of cyanotic congenital heart disease usually managed by serial surgical repairs. The repaired prosthetic valve or conduit is susceptible to life-threatening infection. FDG-PET is an effective alternative to evaluate the source of infection when other examinations are inconclusive. We report an unusual case of an infected pulmonary artery conduit after TOF repair although the echocardiogram was negative for vegetation, which was later confirmed by surgery and pathology. The case highlights the role of FDG-PET as a problem-solving tool for potential endocarditis and cardiac device infection cases after complex cardiac surgery

  4. VLP seismicity from resonant modes of acoustic-gravity waves in a conduit-crack system filled with multiphase magma

    Science.gov (United States)

    Liang, C.; Prochnow, B. N.; OReilly, O. J.; Dunham, E. M.; Karlstrom, L.

    2016-12-01

    Oscillation of magma in volcanic conduits connected to cracks (dikes and sills) has been suggested as an explanation for very long period (VLP) seismic signals recorded at active basaltic volcanoes such as. Kilauea, Hawaii, and Erebus, Antarctica. We investigate the VLP seismicity using a linearized model for waves in and associated eigenmodes of a coupled conduit-crack system filled with multiphase magma, an extension of the Karlstrom and Dunham (2016) model for acoustic-gravity waves in volcanic conduits. We find that the long period surface displacement (as recorded on broadband seismometers) is dominated by opening/closing of the crack rather than the deformation of the conduit conduit walls. While the fundamental eigenmode is sensitive to the fluid properties and the geometry of the magma plumbing system, a closer scrutiny of various resonant modes reveals that the surface displacement is often more sensitive to higher modes. Here we present a systematic analysis of various long period acoustic-gravity wave resonant modes of a coupled conduit-crack system that the surface displacement is most sensitive to. We extend our previous work on a quasi-one-dimensional conduit model with inviscid magma to a more general axisymmetric conduit model that properly accounts for viscous boundary layers near the conduit walls, based on the numerical method developed by Prochnow et al. (submitted to Computers and Fluids, 2016). The surface displacement is dominated by either the fundamental or higher eigenmodes, depending on magma properties and the geometry of conduit and crack. An examination of the energetics of these modes reveals the complex interplay of different restoring forces (magma compressibility in the conduit, gravity, and elasticity of the crack) driving the VLP oscillations. Both nonequilibrium bubble growth and resorption and viscosity contribute to the damping of VLP signals. Our models thus provide a means to infer properties of open-vent basaltic volcanoes

  5. Biological conduits combining bone marrow mesenchymal stem cells and extracellular matrix to treat long-segment sciatic nerve defects

    Directory of Open Access Journals (Sweden)

    Yang Wang

    2015-01-01

    Full Text Available The transplantation of polylactic glycolic acid conduits combining bone marrow mesenchymal stem cells and extracellular matrix gel for the repair of sciatic nerve injury is effective in some respects, but few data comparing the biomechanical factors related to the sciatic nerve are available. In the present study, rabbit models of 10-mm sciatic nerve defects were prepared. The rabbit models were repaired with autologous nerve, a polylactic glycolic acid conduit + bone marrow mesenchymal stem cells, or a polylactic glycolic acid conduit + bone marrow mesenchymal stem cells + extracellular matrix gel. After 24 weeks, mechanical testing was performed to determine the stress relaxation and creep parameters. Following sciatic nerve injury, the magnitudes of the stress decrease and strain increase at 7,200 seconds were largest in the polylactic glycolic acid conduit + bone marrow mesenchymal stem cells + extracellular matrix gel group, followed by the polylactic glycolic acid conduit + bone marrow mesenchymal stem cells group, and then the autologous nerve group. Hematoxylin-eosin staining demonstrated that compared with the polylactic glycolic acid conduit + bone marrow mesenchymal stem cells group and the autologous nerve group, a more complete sciatic nerve regeneration was found, including good myelination, regularly arranged nerve fibers, and a completely degraded and resorbed conduit, in the polylactic glycolic acid conduit + bone marrow mesenchymal stem cells + extracellular matrix gel group. These results indicate that bridging 10-mm sciatic nerve defects with a polylactic glycolic acid conduit + bone marrow mesenchymal stem cells + extracellular matrix gel construct increases the stress relaxation under a constant strain, reducing anastomotic tension. Large elongations under a constant physiological load can limit the anastomotic opening and shift, which is beneficial for the regeneration and functional reconstruction of sciatic nerve. Better

  6. Salt, chloride, bleach, and innate host defense

    Science.gov (United States)

    Wang, Guoshun; Nauseef, William M.

    2015-01-01

    Salt provides 2 life-essential elements: sodium and chlorine. Chloride, the ionic form of chlorine, derived exclusively from dietary absorption and constituting the most abundant anion in the human body, plays critical roles in many vital physiologic functions, from fluid retention and secretion to osmotic maintenance and pH balance. However, an often overlooked role of chloride is its function in innate host defense against infection. Chloride serves as a substrate for the generation of the potent microbicide chlorine bleach by stimulated neutrophils and also contributes to regulation of ionic homeostasis for optimal antimicrobial activity within phagosomes. An inadequate supply of chloride to phagocytes and their phagosomes, such as in CF disease and other chloride channel disorders, severely compromises host defense against infection. We provide an overview of the roles that chloride plays in normal innate immunity, highlighting specific links between defective chloride channel function and failures in host defense. PMID:26048979

  7. Salt, chloride, bleach, and innate host defense.

    Science.gov (United States)

    Wang, Guoshun; Nauseef, William M

    2015-08-01

    Salt provides 2 life-essential elements: sodium and chlorine. Chloride, the ionic form of chlorine, derived exclusively from dietary absorption and constituting the most abundant anion in the human body, plays critical roles in many vital physiologic functions, from fluid retention and secretion to osmotic maintenance and pH balance. However, an often overlooked role of chloride is its function in innate host defense against infection. Chloride serves as a substrate for the generation of the potent microbicide chlorine bleach by stimulated neutrophils and also contributes to regulation of ionic homeostasis for optimal antimicrobial activity within phagosomes. An inadequate supply of chloride to phagocytes and their phagosomes, such as in CF disease and other chloride channel disorders, severely compromises host defense against infection. We provide an overview of the roles that chloride plays in normal innate immunity, highlighting specific links between defective chloride channel function and failures in host defense. © Society for Leukocyte Biology.

  8. Removal of chloride from MSWI fly ash.

    Science.gov (United States)

    Chen, Wei-Sheng; Chang, Fang-Chih; Shen, Yun-Hwei; Tsai, Min-Shing; Ko, Chun-Han

    2012-10-30

    The high levels of alkali chloride and soluble metal salts present in MSWI fly ash is worth noting for their impact on the environment. In addition, the recycling or reuse of fly ash has become an issue because of limited landfill space. The chloride content in fly ash limits its application as basis for construction materials. Water-soluble chlorides such as potassium chloride (KCl), sodium chloride (NaCl), and calcium chloride hydrate (CaCl(2) · 2H(2)O) in fly ash are easily washed away. However, calcium chloride hydroxide (Ca(OH)Cl) might not be easy to leach away at room temperature. The roasting and washing-flushing processes were applied to remove chloride content in this study. Additionally, air and CO(2) were introduced into the washing process to neutralize the hazardous nature of chlorides. In comparison with the water flushing process, the roasting process is more efficient in reducing the process of solid-liquid separation and drying for the reuse of Cl-removed fly ash particles. In several roasting experiments, the removal of chloride content from fly ash at 1050°C for 3h showed the best results (83% chloride removal efficiency). At a solid to liquid ratio of 1:10 the water-flushing process can almost totally remove water-soluble chloride (97% chloride removal efficiency). Analyses of mineralogical change also prove the efficiency of the fly ash roasting and washing mechanisms for chloride removal. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Improved axonal regeneration of transected spinal cord mediated by multichannel collagen conduits functionalized with neurotrophin-3 gene.

    Science.gov (United States)

    Yao, L; Daly, W; Newland, B; Yao, S; Wang, W; Chen, B K K; Madigan, N; Windebank, A; Pandit, A

    2013-12-01

    Functionalized biomaterial scaffolds targeted at improving axonal regeneration by enhancing guided axonal growth provide a promising approach for the repair of spinal cord injury. Collagen neural conduits provide structural guidance for neural tissue regeneration, and in this study it is shown that these conduits can also act as a reservoir for sustained gene delivery. Either a G-luciferase marker gene or a neurotrophin-3-encoding gene, complexed to a non-viral, cyclized, PEGylated transfection vector, was loaded within a multichannel collagen conduit. The complexed genes were then released in a controlled fashion using a dual release system both in vitro and in vivo. For evaluation of their biological performance, the loaded conduits were implanted into the completely transected rat thoracic spinal cord (T8-T10). Aligned axon regeneration through the channels of conduits was observed one month post-surgery. The conduits delivering neurotrophin-3 polyplexes resulted in significantly increased neurotrophin-3 levels in the surrounding tissue and a statistically higher number of regenerated axons versus the control conduits (P<0.05). This study suggests that collagen neural conduits delivering a highly effective non-viral therapeutic gene may hold promise for repair of the injured spinal cord.

  10. A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit.

    Science.gov (United States)

    Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J

    2014-08-01

    A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.

  11. Nitric oxide permits hypoxia-induced lymphatic perfusion by controlling arterial-lymphatic conduits in zebrafish and glass catfish

    DEFF Research Database (Denmark)

    Dahl Ejby Jensen, Lasse; Cao, Renhai; Hedlund, Eva-Maria

    2009-01-01

    and lymphatic perfusion. Here we show in the adult zebrafish and glass catfish (Kryptopterus bicirrhis) that blood-lymphatic conduits directly connect arterial vessels to the lymphatic system. Under hypoxic conditions, arterial-lymphatic conduits (ALCs) became highly dilated and linearized by NO...

  12. Design and production of stopper made of concrete foam composite used for open channel conduit cover and parking bumper

    Science.gov (United States)

    Syam, Bustami; Sebayang, Alexander; Sebayang, Septian; Muttaqin, Maraghi; Darmadi, Harry; Basuki, WS; Sabri, M.; Abda, S.

    2018-03-01

    Open channel conduit is designed and produced with the aims to reduce excess water, whether from rain, seepage, or excess irrigation water in an area. It is also included in one of the important components of urban infrastructure in tackling the problem of flooding and waterlogging. On the roadway, e.g. housing complex the open channel conduits should function the same, however conduit covers are needed. The covers should be also designed to function as parking bumper. This paper discusses the design and production of the stoppers using our newly invented materials; the stoppers are structurally tested under static, dynamic, and bump test. Response of the conduit cover are found from structural analysis using finite element software ANSYS MECHANICAL version 17.5. Two types of stoppers are introduced: flat and curvy configuration. It was obtained that both types are suitable for open channel conduit cover and parking bumper.

  13. Hydrolysis of cupric chloride in aqueous ammoniacal ammonium chloride solutions

    Directory of Open Access Journals (Sweden)

    Limpo, J. L.

    1995-06-01

    Full Text Available Cupric solubility in the CuCl2-NH4Cl-NH3-H2O system for chloride concentrations lower than 4 molal in the temperature range 25-60 °C was studied. The experimental results show that for chloride concentration between 3.0 and 1.0 molal the cupric solubility is determined by the solubility of the cupric hydroxychloride Cu(OH1.5Cl0.5. For a chloride concentration value of 4.0 molal, there are two cupric compounds, the hydroxychloride Cu(OH1.5Cl0.5 or the diammine chloride Cu(NH32Cl2, on which the solubility of Cu(II depends, according to the temperature and the value of the ratio [NH3]Total/[Cu]Total.

    Se estudia la solubilidad del Cu(II en el sistema CuCl2-NH4Cl-NH3-H2O para concentraciones de cloruro inferiores a 4 molal en el intervalo de temperaturas 25-60 °C. Los resultados experimentales muestran que, para concentraciones de cloruros comprendidas entre 3,0 y 1,0 molal, la solubilidad cúprica viene determinada por la solubilidad del hidroxicloruro cúprico, Cu(OH1.5Cl0.5. Para concentraciones de cloruro 4,0 molal, existen dos compuestos cúpricos, el hidroxicloruro, Cu(OH1.5Cl0.5 o el cloruro de diamina, Cu(NH32Cl2, de los que, de acuerdo con la temperatura y con el valor de la relación [NH3]Total/[Cu]Total depende la solubilidad del Cu(II.

  14. A Physicochemically Optimized and Neuroconductive Biphasic Nerve Guidance Conduit for Peripheral Nerve Repair.

    Science.gov (United States)

    Ryan, Alan J; Lackington, William A; Hibbitts, Alan J; Matheson, Austyn; Alekseeva, Tijna; Stejskalova, Anna; Roche, Phoebe; O'Brien, Fergal J

    2017-12-01

    Clinically available hollow nerve guidance conduits (NGCs) have had limited success in treating large peripheral nerve injuries. This study aims to develop a biphasic NGC combining a physicochemically optimized collagen outer conduit to bridge the transected nerve, and a neuroconductive hyaluronic acid-based luminal filler to support regeneration. The outer conduit is mechanically optimized by manipulating crosslinking and collagen density, allowing the engineering of a high wall permeability to mitigate the risk of neuroma formation, while also maintaining physiologically relevant stiffness and enzymatic degradation tuned to coincide with regeneration rates. Freeze-drying is used to seamlessly integrate the luminal filler into the conduit, creating a longitudinally aligned pore microarchitecture. The luminal stiffness is modulated to support Schwann cells, with laminin incorporation further enhancing bioactivity by improving cell attachment and metabolic activity. Additionally, this biphasic NGC is shown to support neurogenesis and gliogenesis of neural progenitor cells and axonal outgrowth from dorsal root ganglia. These findings highlight the paradigm that a successful NGC requires the concerted optimization of both a mechanical support phase capable of bridging a nerve defect and a neuroconductive phase with an architecture capable of supporting both Schwann cells and neurons in order to achieve functional regenerative outcome. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Impact of bed rest on conduit artery remodeling: effect of exercise countermeasures.

    NARCIS (Netherlands)

    Duijnhoven, N.T.L. van; Green, D.J.; Felsenberg, D.; Belavy, D.L.; Hopman, M.T.E.; Thijssen, D.H.J.

    2010-01-01

    Physical inactivity is a potent stimulus for vascular remodeling, leading to a marked decrease in conduit artery diameter. However, little is known about the impact of physical inactivity on artery wall thickness or wall:lumen ratio or the potential of exercise countermeasures to modify artery wall

  16. The Railway and the River: Conduits of Dickens’s Imaginary City

    NARCIS (Netherlands)

    Moore, B.; Murail, E.; Thornton, S.

    2017-01-01

    This chapter analyses the railway and the river as two key conduits of Dickens’ imaginary city, arguing that each simultaneously connects and fractures the modern urban world that he depicts. Focusing on Dombey and Son and Our Mutual Friend, the chapter explores how railway and river combine

  17. Phase separation phenomena in branching conduits. Topical report Dec 78-Dec 81

    International Nuclear Information System (INIS)

    Saba, N.; Lahey, R.T. Jr.

    1982-03-01

    The analysis of Light Water Reactor (LWR) Loss-of-Coolant Accidents (LOCA's) requires that one be able to accurately calculate the two-phase flow splits in complex, branching conduits. The purpose of this study is to provide a general method for calculating the phase separation in a branching conduit. The degree of phase separation of a two-phase (air/water) mixture flowing through a plexiglas tee test section was measured. In addition, flow visualization, using high speed photography, was performed. The experimental design considerations, error analysis and the dependence of the observed phase separation on global parameters, such as inlet quality, mass flux and separation angle, are discussed. The pressure gradients were measured along the various conduits and the differential pressure was obtained at the tee junction by extrapolation. It was found that the degree of phase separation was quite pronounced, with the vapor phase preferentially separating into the branch. Using these data, a physically-based empirical model was developed with which to calculate the phasic distribution of a subsonic two-phase mixture in the downstream branches of a branching conduit

  18. 3D Bioprinting of Heterogeneous Aortic Valve Conduits with Alginate/Gelatin Hydrogels

    Science.gov (United States)

    Duan, Bin; Hockaday, Laura A.; Kang, Kevin H.; Butcher, Jonathan T.

    2013-01-01

    Heart valve disease is a serious and growing public health problem for which prosthetic replacement is most commonly indicated. Current prosthetic devices are inadequate for younger adults and growing children. Tissue engineered living aortic valve conduits have potential for remodeling, regeneration, and growth, but fabricating natural anatomical complexity with cellular heterogeneity remain challenging. In the current study, we implement 3D bioprinting to fabricate living alginate/gelatin hydrogel valve conduits with anatomical architecture and direct incorporation of dual cell types in a regionally constrained manner. Encapsulated aortic root sinus smooth muscle cells (SMC) and aortic valve leaflet interstitial cells (VIC) were viable within alginate/gelatin hydrogel discs over 7 days in culture. Acellular 3D printed hydrogels exhibited reduced modulus, ultimate strength, and peak strain reducing slightly over 7-day culture, while the tensile biomechanics of cell-laden hydrogels were maintained. Aortic valve conduits were successfully bioprinted with direct encapsulation of SMC in the valve root and VIC in the leaflets. Both cell types were viable (81.4±3.4% for SMC and 83.2±4.0% for VIC) within 3D printed tissues. Encapsulated SMC expressed elevated alpha-smooth muscle actin when printed in stiff matrix, while VIC expressed elevated vimentin in soft matrix. These results demonstrate that anatomically complex, heterogeneously encapsulated aortic valve hydrogel conduits can be fabricated with 3D bioprinting. PMID:23015540

  19. Enhancing Peripheral Nerve Regeneration with a Novel Drug-Delivering Nerve Conduit

    Science.gov (United States)

    2015-10-01

    our novel nerve conduit. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE...growth in dorsal root ganglion ( DRG ) cell culture Tasks/Subtasks: 1. In Vitro NGF/GNDF release kinetics experiments.......................... (Gale...Axonal growth of DRGs ................................................................ (Terry, Shea) (11-18months) Progress: We have started these

  20. Percutaneous transthoracic computed tomography-guided AICD insertion in a patient with extracardiac Fontan conduit.

    LENUS (Irish Health Repository)

    Murphy, Darra T

    2011-02-01

    Percutaneous pulmonary venous atrial puncture was performed under computed tomography guidance to successfully place an automated implantable cardiac defibrillator into a 26-year-old patient with extracardiac Fontan conduit who had presented with two out-of-hospital cardiac arrests. The procedure avoided the need for lead placement at thoracotomy.

  1. 76 FR 53678 - Calleguas Municipal Water District Notice of Surrender of Exemption (Conduit)

    Science.gov (United States)

    2011-08-29

    ... Municipal Water District Notice of Surrender of Exemption (Conduit) Pursuant to section 4.95(a) of the Commission's regulations,\\1\\ Calleguas Municipal Water District filed with the Commission a petition to... Municipal Water District, 87 FERC ] 62,256 (1999). \\3\\ See filing of July 11, 2011 by Calleguas Municipal...

  2. Thoracoscopic management of volvulus of the gastric conduit following minimally invasive Ivor-Lewis esophagectomy.

    Science.gov (United States)

    Linson, Jeremy; Latzko, Michael; Ahmed, Bestoun; Awad, Ziad

    2016-07-01

    We present a case of emergent thoracoscopic management of volvulus of the gastric conduit following minimally invasive Ivor-Lewis esophagectomy. The patient is a 69-year-old Caucasian male with a history of adenocarcinoma of the lower third of the esophagus. Initial presentation was dysphagia with solid foods, which progressed in severity until he was unable to swallow anything. EUS demonstrated a partially obstructing mass at 33 cm; biopsy revealed poorly differentiated adenocarcinoma, stage T3N2Mx. PET scan did not reveal any metastatic disease. Preoperative management included neo-adjuvant chemoradiation therapy (5-FU and cisplatin) and early placement of a jejunal feeding tube. Intra-operative leak test was performed as a matter of routine following completion of the esophagogastric anastomosis. A nasogastric tube was placed intra-operatively and removed on POD2 according to our standard pathway. Postoperatively, the patient progressed without difficulty to POD4, when we routinely obtain an upper GI swallow study. This demonstrated a lack of transit of contrast through the distal neo-esophagus. Follow-up endoscopy revealed volvulus of the gastric conduit with obliteration of the lumen. We immediately took the patient to the OR for thoracoscopic detorsion, which we accomplished successfully by entering the existing trochar sites and using blunt dissection.␣Upon entering the thoracic cavity, the staple line that had been oriented anteriorly was now posterior. Attachments were gently teased away from the chest wall and the conduit was detorsed and anchored to the chest wall in the correct orientation with silk suture. Intra-operative endoscopy demonstrated a patent conduit. Postoperative upper GI fluoroscopy now showed good transit of contrast. The patient continued to improve and was eventually advanced to mechanical soft diet and discharged on postoperative day 9. Early intervention is indicated in cases of volvulus of the gastric conduit following Ivor

  3. Synthesis of Zirconium Lower Chlorides

    International Nuclear Information System (INIS)

    Gaviria, Juan P.

    2002-01-01

    This research is accurately related to the Halox concept of research reactor spent fuel element treatment.The aim of this project is to work the conditioning through selected chlorination of the element that make the spent fuel element. This research studied the physical chemistry conditions which produce formation of the lower zirconium chlorides through the reaction between metallic Zr and gaseous ZrCl 4 in a silica reactor.This work focused special attention in the analysis and confrontation of the published results among the different authors in order to reveal coincidences and contradictions.Experimental section consisted in a set of synthesis with different reaction conditions and reactor design. After reaction were analyzed the products on Zr shavings and the deposit growth on wall reactor.The products were strongly dependent of reactor design. It was observed that as the distance between Zr and wall reactor increased greater was tendency to lower chlorides formation.In reactors with small distance the reaction follows other way without formation of lower chlorides.Analysis on deposit growth on reactor showed that may be formed to a mixture of Si x Zr y intermetallics and zirconium oxides.Presence of oxygen in Zr and Zr-Si compounds on wall reactor reveals that there is an interaction between quartz and reactants.This interaction is in gaseous phase because contamination is observed in experiences where Zr was not in contact with reactor.Finally, it was made a global analysis of all experiences and a possible mechanism that interprets reaction ways is proposed

  4. Melting in trivalent metal chlorides

    International Nuclear Information System (INIS)

    Saboungi, M.L.; Price, D.L.; Scamehorn, C.; Tosi, M.P.

    1990-11-01

    We report a neutron diffraction study of the liquid structure of YCl 3 and combine the structural data with macroscopic melting and transport data to contrast the behaviour of this molten salt with those of SrCl 2 , ZnCl 2 and AlCl 3 as prototypes of different melting mechanisms for ionic materials. A novel melting mechanism for trivalent metal chlorides, leading to a loose disordered network of edge-sharing octahedral units in the liquid phase, is thereby established. The various melting behaviours are related to bonding character with the help of Pettifor's phenomenological chemical scale. (author). 25 refs, 4 figs, 3 tabs

  5. Effect of Hydroxyl Concentration on Chemical Sensitivity of Polyvinyl Alcohol/Carbon-Black Composite Chemiresistors

    International Nuclear Information System (INIS)

    Hughes, Robert C.; Patel, Sanjay V.; Yelton, W. Graham

    1999-01-01

    The sensitivity and selectivity of polyvinyl alcohol (PVA) / carbon black composite films have been found to vary depending upon the hydroxylation percentage (''-OH'') of the polymer. These chemiresistors made from PVA films whose polymer backbone is 88% hydroxylated (PVA88) have a high sensitivity to water, while chemiresistors made from PVA75 have a higher sensitivity to methanol. The minor differences in polymer composition result in films with different Hildebrand volubility parameters. The relative responses of several different PVA-based chemiresistors to solvents with different volubility parameters are presented. In addition, polyvinyl acetate (PVAC) films with PVA88 are used in an array to distinguish the responses to methanol-water mixtures

  6. Renal abnormalities in congenital chloride diarrhea

    International Nuclear Information System (INIS)

    Al-Hamad, Nadia M.; Al-Eisa, Amal A.

    2004-01-01

    Congenital chloride diarrhea CLD is a rare autosomal recessive disorder caused by a defect in the chloride/ bicarbonate exchange in the ileum and colon. It is characterized by watery diarrhea, abdominal distension, hypochloremic hypokalemic metabolic alkalosis with high fecal content of chloride >90 mmol/l. We report 3 patients with CLD associated with various renal abnormalities including chronic renal failure secondary to renal hypoplasia, nephrocalcinosis and congenital nephrotic syndrome. (author)

  7. Synthesis of carbon-14 labelled ethyl chloride

    International Nuclear Information System (INIS)

    Kanski, R.

    1976-01-01

    A new efficient method of synthesis of ethyl chloride (1,2- 14 C), based on the Ba 14 CO 3 and dry hydrogen chloride as starting materials has been developed and described. Addition of the hydrogen chloride to ethylene (1,2- 14 C), obtained from Ba 14 CO 3 , has been carried out in the presence of the AlCl 3 as catalyst. The outlined method leads to ethyl chloride (1,2- 14 C) of high specific activity. The radiochemical yield of the reaction based on the activity of barium carbonate used was 72%. (author)

  8. Method of processing chloride waste

    International Nuclear Information System (INIS)

    Tokiwai, Moriyasu; Tsunashima, Mikiyasu; Horie, Masaaki; Koyama, Masafumi; Sudo, Minoru; Kitagawa, Masatoshi; Ogasawara, Tadashi.

    1991-01-01

    In a method of applying molten salt electrolysis to chloride wastes discharged from a electrolytic refining step of a dry reprocessing step for spent fuels, and removed with transuranium elements of long half-decaying time, metals capable of alloying with alkali and alkaline earth metals under melting by electrolysis are used as a cathode material, and an electrolytic temperature is made higher than the melting point of salts in a molten salt electrolysis bath, to recover Li, Ca and Na as alloys with the cathode material in a first electrolysis step. Then, the electrolytic temperature is made higher than the melting point of the chloride salts remained in the bath after the electrolysis step described above by using the cathode material, to recover Ba, Rb, Sr and Cs of nuclear fission products also as alloys with the cathode material in a second electrolysis step. Accordingly, the amount of wastes formed can be reduced, and the wastes contain no heat generating nuclear fission elements. (T.M.)

  9. Electrochemical chloride extraction of a beam polluted by chlorides after 40 years in the sea

    OpenAIRE

    BOUTEILLER, Véronique; LAPLAUD, André; MALOULA, Aurélie; MORELLE, René Stéphane; DUCHESNE, Béatrice; MORIN, Mathieu

    2006-01-01

    A beam element, naturally polluted by chlorides after 40 years of a marine tidal exposure, has been treated by electrochemical chloride extraction. The chloride profiles, before and after treatment, show that free chlorides are extrated with an efficiency of 70 % close to the steel, 50 % in the intermediate cover and only 5 % at the concrete surface. From the electrochemical characterizations (before, after, 1, 2 and 17 months after treatment), the steel potential values can, semehow, indicat...

  10. Thermochemistry of alkali chloride - lanthanoide(III) chlorides

    International Nuclear Information System (INIS)

    Blachnik, R.; Selle, D.

    1979-01-01

    The phase diagrams of the mixtures KCl + GdCl 3 resp. DyCl 3 and of CsCl + PrCl 3 (DyCl 3 , ErCl 3 , and YbCl 3 ) were investigated by differential thermal analysis. In the mixtures of lanthanoide(III) chlorides with CsCl resp. KCl three different stoichiometries of the compounds were found, namely A 3 MCl 6 , A 2 MCl 5 , and AM 2 Cl 7 . Debyeograms of the compounds A 3 MCl 6 and AM 2 Cl 7 reveal, that in the case of the latter type all compounds with the same alkali halide have identical structure, whereas in the A 3 MCl 6 compounds three different types of X-ray patterns were observed. The stabilities of the congruently melting compounds can be estimated by comparing the melting point of the compound with the temperature of an extrapolated eutectic point. (author)

  11. Interstage evaluation of homograft-valved right ventricle to pulmonary artery conduits for palliation of hypoplastic left heart syndrome.

    Science.gov (United States)

    Sandeep, Nefthi; Punn, Rajesh; Balasubramanian, Sowmya; Smith, Shea N; Reinhartz, Olaf; Zhang, Yulin; Wright, Gail E; Peng, Lynn F; Wise-Faberowski, Lisa; Hanley, Frank L; McElhinney, Doff B

    2018-04-01

    Palliation of hypoplastic left heart syndrome with a standard nonvalved right ventricle to pulmonary artery conduit results in an inefficient circulation in part due to diastolic regurgitation. A composite right ventricle pulmonary artery conduit with a homograft valve has a hypothetical advantage of reducing regurgitation, but may differ in the propensity for stenosis because of valve remodeling. This retrospective cohort study included 130 patients with hypoplastic left heart syndrome who underwent a modified stage 1 procedure with a right ventricle to pulmonary artery conduit from 2002 to 2015. A composite valved conduit (cryopreserved homograft valve anastomosed to a polytetrafluoroethylene tube) was placed in 100 patients (47 aortic, 32 pulmonary, 13 femoral/saphenous vein, 8 unknown), and a nonvalved conduit was used in 30 patients. Echocardiographic functional parameters were evaluated before and after stage 1 palliation and before the bidirectional Glenn procedure, and interstage interventions were assessed. On competing risk analysis, survival over time was better in the valved conduit group (P = .040), but this difference was no longer significant after adjustment for surgical era. There was no significant difference between groups in the cumulative incidence of bidirectional Glenn completion (P = .15). Patients with a valved conduit underwent more interventions for conduit obstruction in the interstage period, but this difference did not reach significance (P = .16). There were no differences between groups in echocardiographic parameters of right ventricle function at baseline or pre-Glenn. In this cohort of patients with hypoplastic left heart syndrome, inclusion of a valved right ventricle to pulmonary artery conduit was not associated with any difference in survival on adjusted analysis and did not confer an identifiable benefit on right ventricle function. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier

  12. Challenges of using electrical resistivity method to locate karst conduits-A field case in the Inner Bluegrass Region, Kentucky

    Science.gov (United States)

    Zhu, J.; Currens, J.C.; Dinger, J.S.

    2011-01-01

    Conduits serve as major pathways for groundwater flow in karst aquifers. Locating them from the surface, however, is one of the most challenging tasks in karst research. Geophysical methods are often deployed to help locate voids by mapping variations of physical properties of the subsurface. Conduits can cause significant contrasts of some physical properties that can be detected; other subsurface features such as water-bearing fractures often yield similar contrasts, which are difficult to distinguish from the effects of the conduits. This study used electrical resistivity method to search for an unmapped karst conduit that recharges Royal Spring in the Inner Bluegrass karst region, Kentucky, USA. Three types of resistivity techniques (surface 2D survey, quasi-3D survey, and time-lapse survey) were used to map and characterize resistivity anomalies. Some of the major anomalies were selected as drilling targets to verify the existence of the conduits. Drilling near an anomaly identified by an electrical resistivity profile resulted in successful penetration of a major water-filled conduit. The drilling results also suggest that, in this study area, low resistivity anomalies in general are associated with water-bearing features. However, differences in the anomaly signals between the water-filled conduit and other water-bearing features such as water-filled fracture zones were undistinguishable. The electrical resistivity method is useful in conduit detection by providing potential drilling targets. Knowledge of geology and hydrogeology about the site and professional judgment also played important roles in locating the major conduit. ?? 2011 Elsevier B.V.

  13. Synthesis of MoO 3 and its polyvinyl alcohol nanostructured film

    Indian Academy of Sciences (India)

    The solvent casting method is adopted for the synthesis of MoO3 dispersed polyvinyl alcohol nanostructured film (MoO3–PVA). These synthesized MoO3 and their composite samples are characterized for their structure, morphology, bonding and thermal behaviour by XRD, SEM, IR and DSC techniques, respectively.

  14. Film dosimeters based on methylene blue and methyl orange in polyvinyl alcohol

    DEFF Research Database (Denmark)

    Chung, W.H.; Miller, A.

    1994-01-01

    Polyvinyl alcohol (PVA) films containing methylene blue and methyl orange are useful as gamma and electron radiation dosimeters. Absorbed doses should not exceed 40 kGy for methylene blue and 500 kGy for methyl orange. Because PVA is water-soluble, the films may be made without toxic solvents...

  15. Properties of polyvinyl alcohol/xylan composite films with citric acid.

    Science.gov (United States)

    Wang, Shuaiyang; Ren, Junli; Li, Weiying; Sun, Runcang; Liu, Shijie

    2014-03-15

    Composite films of xylan and polyvinyl alcohol were produced with citric acid as a new plasticizer or a cross-linking agent. The effects of citric acid content and polyvinyl alcohol/xylan weight ratio on the mechanical properties, thermal stability, solubility, degree of swelling and water vapor permeability of the composite films were investigated. The intermolecular interactions and morphology of composite films were characterized by FTIR spectroscopy and SEM. The results indicated that polyvinyl alcohol/xylan composite films had good compatibility. With an increase in citric acid content from 10% to 50%, the tensile strength reduced from 35.1 to 11.6 MPa. However, the elongation at break increased sharply from 15.1% to 249.5%. The values of water vapor permeability ranged from 2.35 to 2.95 × 10(-7)g/(mm(2)h). Interactions between xylan and polyvinyl alcohol in the presence of citric acid become stronger, which were caused by hydrogen bond and ester bond formation among the components during film forming. Copyright © 2013. Published by Elsevier Ltd.

  16. Biaxial stress-strain behavior of chemical and physical gels of poly(vinyl alcohol)

    Czech Academy of Sciences Publication Activity Database

    Meissner, Bohumil; Matějka, Libor

    2008-01-01

    Roč. 49, č. 10 (2008), s. 2560-2567 ISSN 0032-3861 R&D Projects: GA AV ČR IAA400500701 Institutional research plan: CEZ:AV0Z40500505 Keywords : poly(vinyl alcohol) gels * pure shear behavior * constitutive equation Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.331, year: 2008

  17. Clinical Fit of Partial Removable Dental Prostheses Based on Alginate or Polyvinyl Siloxane Impressions.

    Science.gov (United States)

    Fokkinga, Wietske A; Witter, Dick J; Bronkhorst, Ewald M; Creugers, Nico H

    The aim of this study was to analyze the clinical fit of metal-frame partial removable dental prostheses (PRDPs) based on custom trays used with alginate or polyvinyl siloxane impression material. Fifth-year students of the Nijmegen Dental School made 25 correct impressions for 23 PRDPs for 21 patients using alginate, and 31 correct impressions for 30 PRDPs for 28 patients using polyvinyl siloxane. Clinical fit of the framework as a whole and of each retainer separately were evaluated by calibrated supervisors during framework try-in before (first evaluation) and after (second evaluation) possible adjustments (score 0 = poor fit, up to score 3 = good fit). Framework fit and fit of the denture base were evaluated at delivery (third evaluation). Finally, postinsertion sessions were evaluated and total number of sessions needed, sore spots, adjustments to the denture base, and reported food-impaction were recorded. No significant differences in clinical fit (of the framework as a whole, for the retainers, or for the denture base) were found between the groups in the three evaluation sessions. Differences were not found for postinsertion sessions with one exception: in the alginate group, four subjects reported food impaction, versus none in the polyvinyl siloxane group. Clinical fit of metal-frame PRDPs based on impressions with custom trays combined with alginate or polyvinyl siloxane was similar.

  18. Clinical Fit of Partial Removable Dental Prostheses Based on Alginate or Polyvinyl Siloxane Impressions.

    NARCIS (Netherlands)

    Fokkinga, W.A.; Witter, D.J.; Bronkhorst, E.M.; Creugers, N.H.J.

    2017-01-01

    PURPOSE: The aim of this study was to analyze the clinical fit of metal-frame partial removable dental prostheses (PRDPs) based on custom trays used with alginate or polyvinyl siloxane impression material. MATERIALS AND METHODS: Fifth-year students of the Nijmegen Dental School made 25 correct

  19. Recovery of agricultural odors and odorous compounds from polyvinyl fluoride film bags

    Science.gov (United States)

    Accurate sampling methods are necessary when quantifying odor and volatile organic compound emissions at agricultural facilities. The commonly accepted methodology in the U.S. has been to collect odor samples in polyvinyl fluoride bags (PVF, brand name Tedlar®) and, subsequently, analyze with human ...

  20. Comparison of storage stability of odorous VOCs in polyester aluminum and polyvinyl fluoride tedlar bags

    Science.gov (United States)

    Whole air sampling using containers such as flexible bags or rigid canisters is commonly used to collect samples of volatile organic compounds (VOC) in air. The objective of this study was to compare the stability of polyester aluminum (PEA) and polyvinyl fluoride (PVF, brand name Tedlar®) bags for ...

  1. Templated diamond growth on porous carbon foam decorated with polyvinyl alcohol-nanodiamond composite

    Czech Academy of Sciences Publication Activity Database

    Varga, Marián; Stehlík, Štěpán; Kaman, Ondřej; Ižák, Tibor; Domonkos, Mária; Lee, D.S.; Kromka, Alexander

    2017-01-01

    Roč. 119, Aug (2017), s. 124-132 ISSN 0008-6223 R&D Projects: GA ČR GC15-22102J Institutional support: RVO:68378271 Keywords : nucleation * polyvinyl alcohol * nanodiamonds * carbon foam Subject RIV: JJ - Other Materials OBOR OECD: Nano-materials (production and properties) Impact factor: 6.337, year: 2016

  2. Additive effects on phase transition and interactions in poly(vinyl methyl ether) solutions

    Czech Academy of Sciences Publication Activity Database

    Starovoytova, Larisa; Šťastná, J.; Šturcová, Adriana; Konefal, Rafal; Dybal, Jiří; Velychkivska, Nadiia; Radecki, M.; Hanyková, L.

    2015-01-01

    Roč. 7, č. 12 (2015), s. 2572-2583 ISSN 2073-4360 R&D Projects: GA ČR(CZ) GA13-23392S Institutional support: RVO:61389013 Keywords : additives * LCST * poly(vinyl methyl ether) Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.944, year: 2015

  3. Preparation of CuS nanoparticles embedded in poly(vinyl alcohol ...

    Indian Academy of Sciences (India)

    WINTEC

    ray diffraction (XRD) analyses and electron diffraction pattern also revealed the forming of CuS crystal structure in the PVA fibres. Keywords. CuS nanoparticles; electrospinning; poly(vinyl alcohol). 1. Introduction. In the past decade, the preparation of low-dimensional semiconductor nanostructures has become a hotspot of.

  4. Compatibility of Polyvinyl Alcohol with the 241-F/H Tank Farm Liquid Waste

    International Nuclear Information System (INIS)

    Oji, L.N.

    1998-01-01

    This report describes results from laboratory-scale oxidative mineralization of polyvinyl alcohol (PVA), and the evaluation of the F/H Tank Farms as a storage/disposal option for PVA waste solution generated in the Canyons and B-line decontamination operations

  5. The influence of stretching on tensile strength and solubility of poly(vinyl alcohol) fibres

    NARCIS (Netherlands)

    Heikens, D.; Bleijenberg, A.C.A.M.; Hoppenbrouwers, J.J.M.; Barentsen, W.M.

    1971-01-01

    The strength of wet-spun poly(vinyl alcohol) (pva) fibres is given as function of bath-stretching, wet-stretching and hot-stretching. In the two equations derived for strength of wet-stretching and hot-stretching the complex influence of the bath-stretching and hot-stretching is demonstrated. The

  6. Water absorption and its effect on the tensile properties of tapioca starch/polyvinyl alcohol bioplastics

    NARCIS (Netherlands)

    Judawisastra, H.; Sitohang, Ramona; Marta, L.; Mardiyati,

    2017-01-01

    Tapioca is one of the largest sources of starch and makes it suitable to be used for bioplastic material. Addition of polyvinyl alcohol (PVA) has been shown to successfully reduce the brittleness of starch bioplastic. This study aims to investigate the influence of PVA addition to water absorption

  7. Poly(aniline-co-m-aminobenzoic acid) deposited on poly(vinyl ...

    Indian Academy of Sciences (India)

    Abstract. In this work, we have deposited poly(aniline-co-m-aminobenzoic acid) on poly(vinyl alcohol) (PVA) by in situ ... along the polyaniline (PANI) chain results in self dop- ing of PANI and ..... The value of electrical conductivity is found to be ...

  8. Oxidative Mineralization and Characterization of Polyvinyl Alcohol Solutions for Wastewater Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L.N.

    1999-08-31

    The principal objectives of this study are to identify an appropriate polyvinyl alcohol (PVA) oxidative mineralization technique, perform compatibility and evaporation fate tests for neat and mineralized PVA, and determine potential for PVA chemical interferences which may affect ion exchange utilization for radioactive wastewater processing in the nuclear industry.

  9. Oxidative mineralization and characterization of polyvinyl alcohol for compatibility with tank farm processing chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L.N.

    2000-01-04

    Polyvinyl alcohol (PVA) material has been evaluated for use as a cost-effective substitute for conventional cellulose-based disposal materials (decontamination mops and wipes), plastic bags, and disposable personal protection clothing, that are currently used at Savannah River Site. This study also provides process design criteria for ultraviolet/ultrasonic/hydrogen peroxide PVA reactor system.

  10. Compatibility of Polyvinyl Alcohol with the 241-F/H Tank Farm Liquid Waste

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L.N.

    1998-11-25

    This report describes results from laboratory-scale oxidative mineralization of polyvinyl alcohol (PVA), and the evaluation of the F/H Tank Farms as a storage/disposal option for PVA waste solution generated in the Canyons and B-line decontamination operations.

  11. Organogel polymers from 10-undecenoic acid and poly(vinyl acetate)

    Science.gov (United States)

    Organogels are used in a variety of high value applications including the removal of toxic solvents from aqueous environments and the time-controlled release of compounds. One of the most promising gelators is a polyvinyl polymer containing medium chain length carboxylic acids. The existing producti...

  12. Poly(vinyl alcohol)-heparin hydrogels as sensor catheter membranes

    NARCIS (Netherlands)

    Brinkman, E.; van der Does, L.; Bantjes, A.

    1991-01-01

    Poly(vinyl alcohol)-heparin hydrogels with varying water content were synthesized for use as sensor catheter membranes. Films were cast from aqueous mixtures of poly(viny) alcohol) (PVA), a photosensitive cross-linker p-diazonium diphenyl amine polymer (PA), glutaraldehyde (GA) and heparin. After

  13. Influence of polymer chain architecture of poly(vinyl alcohol) on the inhibition of ice recrystallization

    NARCIS (Netherlands)

    Olijve, L.L.C.; Hendrix, M.M.R.M.; Voets, I.K.

    2016-01-01

    Poly(vinyl alcohol) (PVA) is a water-soluble synthetic polymer well-known to effectively block the recrystallization of ice. The effect of polymer chain architecture on the ice recrystallization inhibition (IRI) by PVA remains unexplored. In this work, the synthesis of PVA molecular bottlebrushes is

  14. Disk Refining and Ultrasonication Treated Sugarcane Bagasse Residues for Poly(Vinyl Alcohol) Bio-composites

    Science.gov (United States)

    Qingzheng Cheng; Zhaohui Tong; Luisa Dempere; Lonnie Ingram; Letian Wang; J.Y. Zhu

    2013-01-01

    Disk refining and ultrasonication treated sugarcane bagasse residues reclaimed from the waste stream of a simplified bioethanol process after fermentation were used to fabricate biobased composites with poly(vinyl alcohol) (PVA) by film casting. The morphologies and the size distributions of residue particles were characterized by scanning electronic microscopy and...

  15. Hybrid composite based on poly(vinyl alcohol) and fillers from renewable resources

    Science.gov (United States)

    Hybrid composite laminates consisting of polyvinyl alcohol (PVA) as continuous phase (33% by weight) and lignocellulosic fillers, derived from sugarcane bagasse, apple and orange waste (22% by weight) were molded in a carver press in the presence of water and glycerol such as platicizers agents. Cor...

  16. Oxidative mineralization and characterization of polyvinyl alcohol for compatibility with tank farm processing chemistry

    International Nuclear Information System (INIS)

    Oji, L.N.

    2000-01-01

    Polyvinyl alcohol (PVA) material has been evaluated for use as a cost-effective substitute for conventional cellulose-based disposal materials (decontamination mops and wipes), plastic bags, and disposable personal protection clothing, that are currently used at Savannah River Site. This study also provides process design criteria for ultraviolet/ultrasonic/hydrogen peroxide PVA reactor system

  17. Synthesis of MoO3 and its polyvinyl alcohol nanostructured film

    Indian Academy of Sciences (India)

    Unknown

    †Appa Institute of Engineering and Technology, Gulbarga 585 101, India. MS received 9 December ... The solvent casting method is adopted for the synthesis of MoO3 dispersed polyvinyl ... one dimension, are dispersed in an organic polymer matrix in order to .... applied for the synthesis of other layered ceramic materi- als.

  18. Histochemical demonstration of creatine kinase activity using polyvinyl alcohol and auxiliary enzymes

    NARCIS (Netherlands)

    Frederiks, W. M.; Marx, F.; van Noorden, C. J.

    1987-01-01

    Creatine kinase activity (EC 2.7.3.2.) has been demonstrated in myocardium and skeletal muscle from rats by a method based on the incubation of cryostat sections with a polyvinyl alcohol-containing medium and the use of auxiliary enzymes. Hexokinase and glucose-6-phosphate dehydrogenase were spread

  19. Preparation of CuS nanoparticles embedded in poly(vinyl alcohol)

    Indian Academy of Sciences (India)

    Poly(vinyl alcohol) (PVA)/CuS composite nanofibres were successfully prepared by electrospinning technique and gas–solid reaction. Scanning electron microscopic (SEM) images showed that the average diameter of PVA/CuS fibres was about 150–200 nm. Transmission electron microscopy (TEM) proved that a majority ...

  20. Chloride ingress in cement paste and mortar

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede; Hansen, Per Freiesleben; Coats, Alison M.

    1999-01-01

    In this paper chloride ingress in cement paste and mortar is followed by electron probe microanalysis. The influence of several paste and exposure parameters on chloride ingress are examined (e.g., water-cement ratio, silica fume addition, exposure time, and temperature), The measurements...

  1. Chloride binding site of neurotransmitter sodium symporters

    DEFF Research Database (Denmark)

    Kantcheva, Adriana Krassimirova; Quick, Matthias; Shi, Lei

    2013-01-01

    Neurotransmitter:sodium symporters (NSSs) play a critical role in signaling by reuptake of neurotransmitters. Eukaryotic NSSs are chloride-dependent, whereas prokaryotic NSS homologs like LeuT are chloride-independent but contain an acidic residue (Glu290 in LeuT) at a site where eukaryotic NSSs...

  2. Synthesis of 14C-dehydrocorydaline chloride

    International Nuclear Information System (INIS)

    Zhang Rui; Wang Ding

    1988-01-01

    A method for synthesis of 14 C-dehydrocorydaline chloride is described. In the presence of sodium hydroxide, acetonylpalmatine is reacted with 14 C-methyl iodide in sealed glass ampoule to give 14 C-13-methylpalmatine iodide which is then converted to chloride. The radiochemical purity of 14 C-dehydrocorydaline determined by TLC is over 98% and the labelling efficiency is 54%

  3. Chronopotentiometric chloride sensing using transition time measurement

    NARCIS (Netherlands)

    Abbas, Yawar; de Graaf, D.B.; Olthuis, Wouter; van den Berg, Albert

    2013-01-01

    Detection of chloride ions is crucial to accurately access the concrete structure durability[1]. The existing electrochemical method of chloride ions detection in concrete, potentiometry[1], is not suitable for in-situ measurement due to the long term stability issue of conventional reference

  4. 29 CFR 1915.1017 - Vinyl chloride.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Vinyl chloride. 1915.1017 Section 1915.1017 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... § 1915.1017 Vinyl chloride. Note: The requirements applicable to shipyard employment under this section...

  5. 29 CFR 1926.1152 - Methylene chloride.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Methylene chloride. 1926.1152 Section 1926.1152 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Methylene chloride. Note: The requirements applicable to construction employment under this section are...

  6. 29 CFR 1915.1052 - Methylene chloride.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Methylene chloride. 1915.1052 Section 1915.1052 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... § 1915.1052 Methylene chloride. Note: The requirements applicable to shipyard employment under this...

  7. 29 CFR 1926.1117 - Vinyl chloride.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Vinyl chloride. 1926.1117 Section 1926.1117 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... chloride. Note: The requirements applicable to construction work under this section are identical to those...

  8. Properties of silver chloride track detectors

    International Nuclear Information System (INIS)

    Dmitriev, V.D.; Kocherov, N.P.; Novikova, N.R.; Perfilov, N.A.

    1976-01-01

    The experiments on preparation of silver chloride track detectors and their properties are described. The results of X-ray structural analysis and data on sensitivity to charged particles and actinic light of silver chloride crystals, doped with several elements, are presented. (orig.) [de

  9. Using MODFLOW with CFP to understand conduit-matrix exchange in a karst aquifer during flooding

    Science.gov (United States)

    Spellman, P.; Screaton, E.; Martin, J. B.; Gulley, J.; Brown, A.

    2011-12-01

    Karst springs may reverse flow when allogenic runoff increases river stage faster than groundwater heads and may exchange of surface water with groundwater in the surrounding aquifer matrix. Recharged flood water is rich in nutrients, metals, and organic matter and is undersaturated with respect to calcite. Understanding the physical processes controlling this exchange of water is critical to understanding metal cycling, redox chemistry and dissolution in the subsurface. Ultimately the magnitude of conduit-matrix exchange should be governed by head gradients between the conduit and the aquifer which are affected by the hydraulic conductivity of the matrix, conduit properties and antecedent groundwater heads. These parameters are interrelated and it is unknown which ones exert the greatest control over the magnitude of exchange. This study uses MODFLOW-2005 coupled with the Conduit Flow Processes (CFP) package to determine how physical properties of conduits and aquifers influence the magnitude of surface water-groundwater exchange. We use hydraulic data collected during spring reversals in a mapped underwater cave that sources Madison Blue Spring in north-central Florida to explore which factors are most important in governing exchange. The simulation focused on a major flood in 2009, when river stage increased by about 10 meters over 9 days. In a series of simulations, we varied hydraulic conductivity, conduit diameter, roughness height and tortuosity in addition to antecedent groundwater heads to estimate the relative effects of each parameter on the magnitude of conduit-matrix exchange. Each parameter was varied across plausible ranges for karst aquifers. Antecedent groundwater heads were varied using well data recorded through wet and dry seasons throughout the spring shed. We found hydraulic conductivity was the most important factor governing exchange. The volume of exchange increased by about 61% from the lowest value (1.8x10-6 m/d) to the highest value (6 m

  10. Lorentz force effect on mixed convection micropolar flow in a vertical conduit

    Science.gov (United States)

    Abdel-wahed, Mohamed S.

    2017-05-01

    The present work provides a simulation of control and filtration process of hydromagnetic blood flow with Hall current under the effect of heat source or sink through a vertical conduit (pipe). This work meets other engineering applications, such as nuclear reactors cooled during emergency shutdown, geophysical transport in electrically conducting and heat exchangers at low velocity conditions. The problem is modeled by a system of partial differential equations taking the effect of viscous dissipation, and these equations are simplified and solved analytically as a series solution using the Differential Transformation Method (DTM). The velocities and temperature profiles of the flow are plotted and discussed. Moreover, the conduit wall shear stress and heat flux are deduced and explained.

  11. Engineering based assessment for a shape design of a pediatric ePTFE pulmonary conduit valve.

    Science.gov (United States)

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Miura, Hidekazu; Mura, Seitaro; Yamagishi, Masaaki

    2016-08-01

    The authors examined the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valved conduits quantitatively by our originally developed pediatric pulmonary mechanical circulatory system, in order to suggest the optimal shape design. The system consisted of pneumatically driven right atrium and ventricle model, a pulmonary valve chamber, and elastic pulmonary compliance model with peripheral vascular resistance units, a venous reservoir. We employed two different types of ePTFE valve and evaluated the relationship between the leaflets motion and hemodynamic characteristics by using a high-speed video camera. As a result, we successfully reproduced hemodynamic simulations in our pediatric pulmonary mock system. We confirmed that the presence of bulging sinuses in the pulmonary valved conduit reduced the transvalvular energy loss and increased the valve opening area during systolic period. Our engineering-based in vitro analysis could be useful for proposing a shape design optimization of sophisticated pediatric ePTFE pulmonary valve.

  12. AC losses and stability on large cable-in-conduit superconductors

    Science.gov (United States)

    Bruzzone, Pierluigi

    1998-12-01

    The cable-in-conduit superconductors are preferred for applications where the AC losses and stability are a major concern, e.g., fusion magnets and SMES. A review of coupling currents loss results for both NbTi and Nb 3Sn cable-in-conduit conductors (CICC) is presented and the AC loss relevant features are listed, with special emphasis for the role of the interstrand resistance and strand coating. The transient stability approach for CICCs is discussed and the analytical models are quoted as well as the relevant experimental database. The likely spectrum of transient disturbance in CICC is reviewed and the need to account for interstrand current sharing in the design is outlined. Eventually a practical criterion for the interstrand resistance is proposed to link the stability and AC loss design.

  13. Electromagnetic nondestructive testing at high lift-off using a magnetic image conduit

    International Nuclear Information System (INIS)

    Lee, Jin Yi; Jun, Jong Woo; Kim, Jung Min; Le, Min Hhuy

    2013-01-01

    To protect sensors from the extreme environments, such as, heat, moisture, pollution and radiation, cracks must be inspected for; this can be done by measuring the distribution of magnetic fields at high lift-off through nondestructive electro-magnetic testing. However, as the intensity of an electro-magnetic field is inversely proportional to the square of the lift-off, it becomes increasingly difficult to effective inspect a crack as the lift-off increases. In this paper, a magnetic image conduit to minimize the intensity loss of an electro-magnetic field at high lift-off is proposed, and the effectiveness of a conduit for magnetic imaging is verified by means of both theoretical and experimental approaches.

  14. Dechlorinating reaction of organic chlorides

    Energy Technology Data Exchange (ETDEWEB)

    Yahata, Taneaki; Kihara, Shinji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Ohuchi, Misao

    1996-06-01

    Dechlorination has been examined by the reaction between iron, aluminum powder or CaO and organic chlorides such as C{sub 2}HCl{sub 3} and CH{sub 2}Cl{sub 2}. Progress of the reaction was analyzed with mass spectrometer. The reaction between iron and organic chloride was rapidly occurred at the temperature between 350 and 440degC in an atmosphere of argon. Above 380degC, more than 99.5% of C{sub 2}HCl{sub 3} was decomposed within approximately 100 minutes. At 440degC, approximately 60% of C{sub 2}HCl{sub 3} was decomposed by the reaction with aluminium powder within approximately 100 minutes. At 440degC, reaction between C{sub 2}HCl{sub 3} and CaO powder were occurred rapidly in an atmosphere of argon to form CaCl{sub 2} and free carbon. Also in an atmosphere of air, nearly the same result was obtained. In this reaction, CaCl{sub 2}, CO and CO{sub 2} were formed. CH{sub 2}Cl{sub 2} was also decomposed by the reaction with iron at the temperature between 380 and 440degC. In the reaction, FeCl{sub 2}, carbon and hydrogen were formed. CH{sub 3}{sup +} and CH{sub 4} were observed during the dechlorinating reaction of CH{sub 2}Cl{sub 2}. Variation in particle size of iron powder such as 100, 150 and 250 mesh did not affect the reaction rate. (author)

  15. Ceramic fiber blanket wrap for fire protection of cable trays and conduits

    International Nuclear Information System (INIS)

    Chaille, C.E.; Reiman, R.J.

    1980-01-01

    In some areas of nuclear power plants, cables of redundant electrical systems, which are necessary for the safe shutdown of the reactor, are in close proximity. If a fire should occur in one of these areas, both electrical systems could be destroyed before the fire is extinguished and control of the reactor may be lost. A ceramic fiber blanket was evaluated as a fire protective wrap around cable trays and conduits. 2 refs

  16. Ileal-conduit following cystectomy, single-institution revision of indications and outcome

    International Nuclear Information System (INIS)

    Abol-Enein, Hassan A.; Abdul-Muhsin, Ausama S.; Alhallaq, Yousuf M.

    2008-01-01

    Objective was to revise indications, case fatality ratio, and postoperative early and late complications of ileal conduit as a method of urinary diversion. This is a retrospective study in which 200 patients underwent an ileal conduit from August 1994 to December 2000 in Mansoura Urology and Nephrology Center, Mansoura, Egypt. Preoperative criteria of patient selection, preoperative findings and postoperative follow-up data were reviewed. In 200 patients aged 29-75 years, with a mean age of 55.84-/+ 8.91 years, the ileal conduit was chosen as a method of urinary diversion, due to one of the following patient or surgical factors; 50 (25%) cardiopulmonary co-morbidities, 27(13.5%) liver cirrhosis, 20 (10%) impaired renal function, 18 (9%) poorly controlled diabetes mellitus and 3 (1.5%) morbid obesity. Frozen section pathological examination showed carcinoma invasion of the urethra in 26 (13%) and prostate stroma in 16 (8%) male patients. Severe adhesions and difficulty cystectomy were encountered in 25 (12.5%) patients. Tumor was found at or close to the bladder neck in 13 (6.5%) female patients and 2 (1%) patients were found to have short mesentery. The mean follow up period was 90.02 -/+ 22.63 months. Fatality rate was 2%. Twenty-three (11.5%) patients had early complications, while 36 (23.7%) patients had late complications. Ileal conduit is still the best urinary diversion method in many patients who have bladder cancer with associated chronic medical disease or certain surgical factors that render other urinary diversion methods more difficult carry more postoperative morbidity and mortality or both. (author)

  17. Development and fabrication of superconducting hybrid Cable-In-Conduit-Conductor (CICC) for indigenous fusion programme

    International Nuclear Information System (INIS)

    Singh, A.K.; Hussain, M.M.; Abdulla, K.K.; Singh, R.P.

    2011-01-01

    The Atomic Fuels Division has initiated development and fabrication of Cable-In-Conduit-Conductor (CICC) of various configurations, for superconducting fusion grade magnets required for their indigenous Fusion Programme. The process involves development of high grade superconducting multifilamentary wire, multi stage cabling of superconducting as well as copper wires and, finally, jacketing of the cables in SS316LN tubes. The overview of the development and fabrication of CICC is presented in this article. (author)

  18. Natural Occurring Silks and Their Analogues as Materials for Nerve Conduits

    OpenAIRE

    Christine Radtke

    2016-01-01

    Spider silk and its synthetic derivatives have a light weight in combination with good strength and elasticity. Their high cytocompatibility and low immunogenicity make them well suited for biomaterial products such as nerve conduits. Silk proteins slowly degrade enzymatically in vivo, thus allowing for an initial therapeutic effect such as in nerve scaffolding to facilitate endogenous repair processes, and then are removed. Silks are biopolymers naturally produced by many species of arthropo...

  19. Selective reinnervation: a comparison of recovery following microsuture and conduit nerve repair.

    Science.gov (United States)

    Evans, P J; Bain, J R; Mackinnon, S E; Makino, A P; Hunter, D A

    1991-09-20

    Selective reinnervation was studied by comparing the regeneration across a conventional neurorraphy versus a conduit nerve repair. Lewis rats underwent right sciatic nerve transection followed by one of four different nerve repairs (n = 8/group). In groups I and II a conventional neurorraphy was performed and in groups III and IV the proximal and distal stumps were coapted by use of a silicone conduit with an interstump gap of 5 mm. The proximal and distal stumps in groups I and III were aligned anatomically correct and the proximal stump was rotated 180 degrees in groups II and IV (i.e. proximal peroneal nerve opposite the distal tibial nerve and the proximal tibial nerve opposite the distal peroneal nerve). By 14 weeks, there was an equivalent, but incomplete return in sciatic function index (SFI) in groups I, III, and IV as measured by walking track analysis. However, the SFI became unmeasurable by 6 weeks in all group II animals. At 14 weeks, the percent innervation of the tibialis anterior and medial gastronemius muscles by the peroneal and tibial nerves respectively was estimated by selective compound muscle action potential amplitude recordings. When fascicular alignment was reversed, there was greater tibial (P = 0.02) and lesser peroneal (P = 0.005) innervation of the gastrocnemius muscle in the conduit (group IV) versus the neurorraphy (group II) group. This suggests that the gastrocnemius muscle may be selectively reinnervated by the tibial nerve. However, there was no evidence of selective reinnervation of the tibialis anterior muscle. Despite these differences, the functional recovery in both conduit repair groups (III and IV) was equivalent to a correctly aligned microsuture repair (group I) and superior to that in the incorrectly aligned microsuture repair (group II).

  20. Bronchovascular reconstruction with a bovine pericardial conduit and surgical reintervention due to thrombosis with revascularisation.

    Science.gov (United States)

    Peña, Emilio; Blanco, Montserrat; Otero, Teresa

    2014-01-01

    We present the case of a 57-year-old male with left hilar squamous cell carcinoma infiltrating the pulmonary artery and in whom a sleeve bronchoplasty and angioplasty were performed using a bovine pericardial conduit. Three days post-operatively, graft thrombosis was detected; thrombectomy and graft reconstruction were performed with revascularisation of the graft. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.