WorldWideScience

Sample records for polymer dialysis needle

  1. Growth of ZnSe nano-needles by pulsed laser deposition and their application in polymer/inorganic hybrid solar cells

    International Nuclear Information System (INIS)

    Chen, L.; Lai, J.S.; Fu, X.N.; Sun, J.; Ying, Z.F.; Wu, J.D.; Lu, H.; Xu, N.

    2013-01-01

    Using pulsed-laser deposition method, crystalline ZnSe nano-needles have been grown on catalyst-coated silicon (100) substrates. The crystalline ZnSe nano-needles with the middle diameters of about 20–80 nm, and the lengths ranging from 100 to 600 nm can be grown densely on 300–400 °C substrates. The as-grown ZnSe nano-needles were well crystalline and base-grown. They are potential electron-capturing materials in polymer/inorganic hybrid solar cells for their properties of good electron-conductance and high ratio surface area. Based on the ZnSe nano-needle cathode, a five-layer composite structure of polymer/inorganic hybrid solar cell has been designed and fabricated. The absorption spectra of the blend of regioregular poly(3-hexylthiophene-2,5-diyl) and phenyl-C61-butyric acid methyl ester (P3HT:PCBM), ZnSe nano-needles and the combination of P3HT:PCBM and ZnSe nano-needles were examined by ultraviolet–visible-infrared spectrophotometer, respectively. The absorption bands of the combination of P3HT:PCBM and ZnSe nano-needles fit well with the solar spectral distribution. - Highlights: ► Crystalline ZnSe nano-needles grown by pulsed laser deposition. ► A five-layer polymer/inorganic hybrid solar cell based on ZnSe nano-needles cathode. ► ZnSe nano-needles improve light absorption. ► Employment of ZnSe nano-needles increase the open-circuit voltage and fill factor

  2. Peritoneal Dialysis

    Science.gov (United States)

    ... include: Infections. An infection of the abdominal lining (peritonitis) is a common complication of peritoneal dialysis. An ... day. You might have a lower risk of peritonitis because you connect and disconnect to the dialysis ...

  3. Equilibrium Dialysis

    African Journals Online (AJOL)

    context of antimicrobial therapy in malnutrition. Dialysis has in the past presented technical problems, being complicated and time-consuming. A new dialysis system based on the equilibrium technique has now become available, and it is the principles and practical application of this apparatus (Kontron Diapack; Kontron.

  4. High-Quality Large-Magnification Polymer Lens from Needle Moving Technique and Thermal Assisted Moldless Fabrication Process.

    Directory of Open Access Journals (Sweden)

    Ratthasart Amarit

    Full Text Available The need of mobile microscope is escalating as well as the demand of high quality optical components in low price. We report here a novel needle moving technique to fabricate milli-size lens together with thermal assist moldless method. Our proposed protocol is able to create a high tensile strength structure of the lens and its base which is beneficial for exploiting in convertinga smart phone to be a digital microscope. We observe that no bubble trapped in a lens when this technique is performed which can overcome a challenge problem found in a typical dropping technique. We demonstrate the symmetry, smoothness and micron-scale resolution of the fabricated structure. This proposed technique is promising to serve as high quality control mass production without any expensive equipment required.

  5. Dialysis centers - what to expect

    Science.gov (United States)

    ... kidneys - dialysis centers; Dialysis - what to expect; Renal replacement therapy - dialysis centers; End-stage renal disease - dialysis ... to a tube that connects to the dialysis machine. Your blood will flow through the tube, into ...

  6. Dialysis Facility Compare

    Data.gov (United States)

    U.S. Department of Health & Human Services — Dialysis Facility Compare helps you find detailed information about Medicare-certified dialysis facilities. You can compare the services and the quality of care that...

  7. Critical Care Dialysis System

    Science.gov (United States)

    1992-01-01

    Organon Teknika Corporation's REDY 2000 dialysis machine employs technology originally developed under NASA contract by Marquardt Corporation. The chemical process developed during the project could be applied to removing toxic waste from used dialysis fluid. This discovery led to the development of a kidney dialysis machine using "sorbent" dialysis, a method of removing urea from human blood by treating a dialysate solution. The process saves electricity and, because the need for a continuous water supply is eliminated, the patient has greater freedom.

  8. Myths in peritoneal dialysis.

    Science.gov (United States)

    Lee, Martin B; Bargman, Joanne M

    2016-11-01

    To clarify misconceptions about the feasibility and risks of peritoneal dialysis that unnecessarily limit peritoneal dialysis uptake or continuation in patients for whom peritoneal dialysis is the preferred dialysis modality. The inappropriate choice of haemodialysis as a result of these misconceptions contributes to low peritoneal dialysis penetrance, increases transfer from peritoneal dialysis to haemodialysis, increases expenditure on haemodialysis and compromises quality of life for these patients. Peritoneal dialysis is an excellent renal replacement modality that is simple, cost-effective and provides comparable clinical outcomes to conventional in-centre haemodialysis. Unfortunately, many patients are deemed unsuitable to start or continue peritoneal dialysis because of false or inaccurate beliefs about peritoneal dialysis. Here, we examine some of these 'myths' and critically review the evidence for and against each of them. We review the feasibility and risk of peritoneal dialysis in patients with prior surgery, ostomies, obesity and mesh hernia repairs. We examine the fear of mediastinitis with peritoneal dialysis after coronary artery bypass graft surgery and the belief that the use of hypertonic glucose dialysate causes peritoneal membrane failure. By clarifying common myths about peritoneal dialysis, we hope to reduce overly cautious practices surrounding this therapy.

  9. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  10. Effectiveness of peritonaeal dialysis

    Directory of Open Access Journals (Sweden)

    Jovanović Nataša

    2005-01-01

    Full Text Available Introduction. In the last few years, an increasing number of patients suffering from terminal renal disease of various leading causes was treated with renal replacement therapy. Peritonaeal dialysis involves an exchange of water and solutes between blood in the peritonaeal capillaries and dialysate in the peritonaeal cavum throughout the peritonaeum. Effective dialysis treatment should provide good quality of life, decrease the number of physical complaints, and bring the incidence of morbidity and mortality closer to the incidence of morbidity and mortality in the healthy population. Aim. The aim of this study was the evaluation of peritonaeal transport characteristics and dialysis effectiveness in 58 patients affected by terminal renal disease who underwent peritonaeal dialysis treatment during August 2003 at the Clinic of Nephrology of the Clinical Centre of Serbia. Method. We examined 30 male and 28 female patients, with an average age of 52 years (range 26 to 78 years. The average duration of peritoneal dialysis treatment was 20 months (ranging from 2 to 66 months, and the end-stage renal failure was caused by different leading disease in our patients. We applied different dialysis modalities: continuous ambulatory peritonaeal dialysis (CAPD with three to five 2- or 3-litre exchanges daily, cyclic peritonaeal dialysis (CCPD, intermittent peritonaeal dialysis (IPD, or automatic peritonaeal dialysis (APD, according to the transport characteristics of the peritonaeal membrane, the residual renal function (RRF, and the clinical status of the patients, in order to perform adequate depuration as suggested by the new international criteria. A peritonaeal equilibrium test (PET was performed according to the new international advice; urea and creatinine clearances (Kt/V and Ccr as well as RRF were calculated using the internationally suggested formulas. Results. Most of our patients received effective dialysis treatment, thanks to the modulation of

  11. Needle autopsy

    Directory of Open Access Journals (Sweden)

    Philip Davis Marsden

    1997-04-01

    Full Text Available Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsia limitadamente fechada, para esclarecimento da histologia do órgão. Dessa maneira, o clínico pode resolver enigmas de doenças fatais.

  12. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  13. Advances in peritoneal dialysis

    NARCIS (Netherlands)

    Krediet, R. T.

    2007-01-01

    New peritoneal dialysis (PD) patients have a better survival than new haemodialysis (HD) patients in the first years on dialysis. During long-term treatment, this changes into a survival advantage for HD. The superior initial survival on PD is related to a better preservation of residual renal

  14. Amyloidosis associated with dialysis

    International Nuclear Information System (INIS)

    Schadmand, S.; Klose, K.J.; Wandel, E.

    1991-01-01

    Amongst the complications of dialysis, amyloid osteopathy is getting increasingly significant. It is due to deposition of β2-microglobulin. To determine the incidence and time of development of this complication, the skeletal radiographs of 185 patients undergoing dialysis, some for up to ten years, were analysed retrospectively. In about 10% of patients, the presence of β2-microglobulin osteopathy may be expected. The radiological features, sites of predilection and differential diagnosis of amyloid osteopathy and of other skeletal changes due to dialysis are discussed. (orig.) [de

  15. Peritoneal Dialysis in Children*

    African Journals Online (AJOL)

    1971-06-02

    Jun 2, 1971 ... efficiency due to vasodilatation of the peritoneal vessels.' DIALYSIS ... osmotic load in the face of a decreasing blood urea and may thus help ... infection, heart failure, sodium and volume de- depletion; ..... around the catheter.

  16. Dialysis Extraction for Chromatography

    Science.gov (United States)

    Jahnsen, V. J.

    1985-01-01

    Chromatographic-sample pretreatment by dialysis detects traces of organic contaminants in water samples analyzed in field with minimal analysis equipment and minimal quantities of solvent. Technique also of value wherever aqueous sample and solvent must not make direct contact.

  17. Dialysis Facility Compare Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — These are the official datasets used on the Medicare.gov Dialysis Facility Compare Website provided by the Centers for Medicare and Medicaid Services. These data...

  18. Your Dialysis Care Team

    Science.gov (United States)

    ... A to Z Health Guide Your Dialysis Care Team Tweet Share Print Email Good health care is ... dialyzers (artificial kidneys) for reuse. Vascular Access Care Team If you are a hemodialysis patient, another group ...

  19. Fabrication of a Polymer Micro Needle Array by Mask-Dragging X-Ray Lithography and Alignment X-Ray Lithography

    Science.gov (United States)

    Li, Yi-Gui; Yang, Chun-Sheng; Liu, Jing-Quan; Sugiyama, Susumu

    2011-03-01

    Polymer materials such as transparent thermoplastic poly(methyl methacrylate) (PMMA) have been of great interest in the research and development of integrated circuits and micro-electromechanical systems due to their relatively low cost and easy process. We fabricated PMMA-based polymer hollow microneedle arrays by mask-dragging and aligning x-ray lithography. Techniques for 3D micromachining by direct lithography using x-rays are developed. These techniques are based on using image projection in which the x-ray is used to illuminate an appropriate gold pattern on a polyimide film mask. The mask is imaged onto the PMMA sample. A pattern with an area of up to 100 × 100mm2 can be fabricated with sub-micron resolution and a highly accurate order of a few microns by using a dragging mask. The fabrication technology has several advantages, such as forming complex 3D micro structures, high throughput and low cost.

  20. Dialysis and contrast media

    International Nuclear Information System (INIS)

    Morcos, Sameh K.; Thomsen, Henrik S.; Webb, Judith A.W.

    2002-01-01

    In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, protein binding, hydrophilicity, and electrical charge of the contrast medium. Generally, several hemodialysis sessions are needed to removal all contrast medium, whereas it takes 3 weeks for continuous ambulatory dialysis to remove the agent completely. There is no need to schedule the dialysis in relation to the injection of iodinated or MR contrast media or the injection of contrast agent in relation to the dialysis program. Hemodialysis does not protect poorly functioning kidneys against contrast-medium-induced nephrotoxicity. Simple guidelines are given. (orig.)

  1. Dialysis access, infections, and hospitalisations in unplanned dialysis start patients

    DEFF Research Database (Denmark)

    Machowska, Anna; Alscher, Mark Dominik; Vanga, Satyanarayana Reddy

    2017-01-01

    Introduction: Unplanned dialysis start (UPS) associates with worse clinical outcomes, higher utilisation of healthcare resources, lower chances to select dialysis modality and UPS patients typically commenced in-centre haemodialysis (HD) with central venous catheter (CVC). We evaluated patient ou...

  2. Fabrication of a Polymer Micro Needle Array by Mask-Dragging X-Ray Lithography and Alignment X-Ray Lithography

    International Nuclear Information System (INIS)

    Li Yi-Gui; Yang Chun-Sheng; Liu Jing-Quan; Sugiyama Susumu

    2011-01-01

    Polymer materials such as transparent thermoplastic poly(methyl methacrylate) (PMMA) have been of great interest in the research and development of integrated circuits and micro-electromechanical systems due to their relatively low cost and easy process. We fabricated PMMA-based polymer hollow microneedle arrays by mask-dragging and aligning x-ray lithography. Techniques for 3D micromachining by direct lithography using x-rays are developed. These techniques are based on using image projection in which the x-ray is used to illuminate an appropriate gold pattern on a polyimide film mask. The mask is imaged onto the PMMA sample. A pattern with an area of up to 100 × 100mm 2 can be fabricated with sub-micron resolution and a highly accurate order of a few microns by using a dragging mask. The fabrication technology has several advantages, such as forming complex 3D micro structures, high throughput and low cost. (cross-disciplinary physics and related areas of science and technology)

  3. Phosphate control in dialysis

    Directory of Open Access Journals (Sweden)

    Cupisti A

    2013-10-01

    Full Text Available Adamasco Cupisti,1 Maurizio Gallieni,2 Maria Antonietta Rizzo,2 Stefania Caria,3 Mario Meola,4 Piergiorgio Bolasco31Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy; 2Nephrology and Dialysis Unit, San Carlo Borromeo Hospital, Milan, Italy; 3Territorial Department of Nephrology and Dialysis, ASL Cagliari, Italy; 4Sant'Anna School of Advanced Studies, University of Pisa, Pisa, ItalyAbstract: Prevention and correction of hyperphosphatemia is a major goal of chronic kidney disease–mineral and bone disorder (CKD–MBD management, achievable through avoidance of a positive phosphate balance. To this aim, optimal dialysis removal, careful use of phosphate binders, and dietary phosphate control are needed to optimize the control of phosphate balance in well-nourished patients on a standard three-times-a-week hemodialysis schedule. Using a mixed diffusive–convective hemodialysis tecniques, and increasing the number and/or the duration of dialysis tecniques are all measures able to enhance phosphorus (P mass removal through dialysis. However, dialytic removal does not equal the high P intake linked to the high dietary protein requirement of dialysis patients; hence, the use of intestinal P binders is mandatory to reduce P net intestinal absorption. Unfortunately, even a large dose of P binders is able to bind approximately 200–300 mg of P on a daily basis, so it is evident that their efficacy is limited in the case of an uncontrolled dietary P load. Hence, limitation of dietary P intake is needed to reach the goal of neutral phosphate balance in dialysis, coupled to an adequate protein intake. To this aim, patients should be informed and educated to avoid foods that are naturally rich in phosphate and also processed food with P-containing preservatives. In addition, patients should preferentially choose food with a low P-to-protein ratio. For example, patients could choose egg white or protein from a vegetable source

  4. Osteoarthropathy in dialysis amyloidosis

    International Nuclear Information System (INIS)

    Baldrati, L.; Feletti, C.; Capponcini, C.; Docci, D.; Rocchi, A.; Balbi, B.; Bonsanto, R.; Mughetti, M.; Pasini, A.

    1991-01-01

    Many long-term (>60 months) hemodialysis patients develop a severe osteoarticular disease, called 'dialysis arthropathy', which is characterized by the deposition in bone and synovia of a new type of amyloid made mainly of β 2 -microglobulin. In the present study, 31 patients (17 males, 14 females; age 54.1±13 years) undergoing chronic hemodialysis arthropathy by means of clinics and of radiological investigations (conventional radiography and computed tomography). Sixteen patients (51.6%) had radiographic evidence of dialysis arthropathy: geodes (shoulders, 12 cases; wrists, 11; hips, 2; knees, 2) and/or destructive arthropathies (cervical spine, 13 cases; dorsolumbar spine, 2; hands, 2; hips, 1). Within 24 months, these lesions were found to progress slowly in the majoriry of cases. In the diagnostic process, CT should be employed in the study of spine, shoulders and hips when the lesions have not been sufficiently demonstrated by conventional radiography in the presence of evident clinical signs. Patients with dialysis arthropathy had undergone dialysis for longer periods than those without it (p<0.005) and showed a significantly higher incidence of both carpal tunnel syndrome (p<0.0005) and shoulder pain (p<0.005). Our findings confirm the high incidence and clinical importance of dialysis arthropathy in long-term hemodialysis patients end the value of diagnostic imaging in screening such patients for those lesions

  5. Filtering Dialysis Myths from Facts

    Science.gov (United States)

    ... to work. Fact: Many dialysis patients continue to work, go to school, or volunteer . Some take time off when they first start dialysis treatment and back to work or school after they have gotten used to ...

  6. Peritoneal Dialysis in Children*

    African Journals Online (AJOL)

    1971-06-02

    Jun 2, 1971 ... cellular fluid' into the peritoneal cavity allows both the removal of excess fluid ... occur. In adults the maximum peritoneal urea clearance is ob- tained with a dialysis ..... and Records. Pulse and respiration rates, temperature and blood .... diffusion of urea out of the brain cells, with consequent movement of ...

  7. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  8. Needle phobia during pregnancy.

    Science.gov (United States)

    Searing, Kimberly; Baukus, Mary; Stark, Mary Ann; Morin, Karen H; Rudell, Barb

    2006-01-01

    The objective of this study was to understand the experience of a pregnant woman with needle phobia and examine its impact on her antepartum, intrapartum, and postpartum experience. A case study format was employed. A 21-year-old primiparous woman with diagnosed needle phobia was interviewed, and her prenatal and delivery records were reviewed. Three tasks during pregnancy were identified: seeking trusting relationships with health care providers; establishing and maintaining control and understanding; and coping with fear of needles, pain, and invasion. As frequent caregivers during childbearing, nurses with an understanding of needle phobia can help to establish trusting relationships with women with this phobia and support them and their families during childbearing and their encounters with needles. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  9. Modified microdissection electrocautery needle

    OpenAIRE

    Singh, Virendra; Kumar, Pramod

    2014-01-01

    Electrocautery is routinely used in surgical procedures. The commercially available microdissection electrocautery needles are costly. To overcome this disadvantage, we have modified monopolar electrocautery tip to function as well as commercially available systems.

  10. Peritoneal Dialysis Dose and Adequacy

    Science.gov (United States)

    ... infused dialysis solution and how much urea and creatinine have entered into the solution during a 4-hour dwell. The peritoneal transport rate varies from person to person. People who have a high rate of transport absorb dextrose from the dialysis ...

  11. Peritoneal Dialysis in Western Countries

    NARCIS (Netherlands)

    Struijk, Dirk G.

    2015-01-01

    Peritoneal dialysis (PD) for the treatment of end-stage renal failure was introduced in the 1960s. Nowadays it has evolved to an established therapy that is complementary to hemodialysis (HD), representing 11% of all patients treated worldwide with dialysis. Despite good clinical outcomes and

  12. Metabolic alterations in dialysis patients

    NARCIS (Netherlands)

    Drechsler, Christiane

    2010-01-01

    Assessing metabolic risk in dialysis patients, three main aspects are important: a) the pathophysiologic effects of metabolic disturbances as known from the general population are unlikely to completely reverse once patients reach dialysis. b) Specific additional problems related to chronic kidney

  13. Peritoneal Dialysis in Asia.

    Science.gov (United States)

    Kwong, Vickie Wai-Ki; Li, Philip Kam-Tao

    2015-12-01

    There is a growing demand of dialysis in Asia for end-stage renal failure patients. Diabetes mellitus is the leading cause of end-stage renal failure in many countries in Asia. The growth of peritoneal dialysis (PD) in Asia is significant and seeing a good trend. With the enhanced practices of PD, the quality of care in PD in Asia is also improved. Overall, PD and hemodialysis (HD) are comparable in clinical outcome. There is a global trend in the reduction of peritonitis rates and Asian countries also witness such improvement. The socio-economic benefits of PD for end-stage renal failure patients in both urban and rural areas in the developed and developing regions of Asia are an important consideration. This can help to reduce the financial burden of renal failure in addressing the growing demand of patients on dialysis. Initiatives should be considered to further drive down the cost of PD in Asia. Growing demand for dialysis by an increasing number of end-stage renal failure patients requires the use of a cost-effective quality dialysis modality. PD is found to be comparable to HD in outcome and quality. In most countries in Asia, PD should be more cost-effective than HD. A 'PD-first' or a 'PD as first considered therapy' policy can be an overall strategy in many countries in Asia in managing renal failure patients, taking the examples of Hong Kong and Thailand. (1) PD is cheaper than HD and provides a better quality of life worldwide, but its prevalence is significantly lower than that of HD in all countries, with the exception of Hong Kong. Allowing reimbursement of PD but not HD has permitted to increase the use of PD over HD in many Asian countries like Hong Kong, Vietnam, Taiwan, Thailand, as well as in New Zealand and Australia over the last years. In the Western world, however, HD is still promoted, and the proportion of patients treated with PD decreases. Japan remains an exception in Asia where PD penetration is very low. Lack of adequate education of

  14. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho

    2017-01-30

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  15. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho; Perez, Jose E.; Ivanov, Yurii; Bertoncini, Andrea; Liberale, Carlo; Kosel, Jü rgen

    2017-01-01

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  16. Peritoneal dialysis in Asia.

    Science.gov (United States)

    Cheng, I K

    1996-01-01

    The socioeconomic status of Asian countries is diverse, and government reimbursement policies for treatment of patients suffering from end-stage renal disease (ESRD) vary greatly from one country to another. Both of these factors have a major impact not only on the choice of treatment for ESRD but also on the utilization of peritoneal dialysis (PD) in this region. Based on the data collected from 11 representative Asian countries, several observations can be made. First, the treatment rates for ESRD in these countries correlated closely with their gross domestic product (GDP) per capita income. Second, the PD utilization rate appeared to have a biphasic relationship with the GDP per capita income and treatment rate, in that countries with the highest and the lowest treatment rates tended to have lower PD utilization rates, whereas countries with modest treatment rates tended to have higher PD utilization rates. The reason for low PD utilization in countries with the highest treatment rates differs from that in countries with low treatment rates. In the former, because of full government reimbursement, there is little physician incentive to introduce PD as an alternative form of ESRD treatment to in-center hemodialysis (HD), whereas in the latter, the complete lack of government reimbursement prevents the introduction of PD as a form of treatment. This pattern is likely to change in the future because, of the 11 countries surveyed, all except Thailand have recorded a growth rate which is higher for PD than HD over the last three years. The rate of utilization of different PD systems varies greatly among different Asian countries. Automated PD has yet to gain popularity in Asia. Conventional straight-line systems remain the dominant PD systems in use in Hong Kong, Korea, Thailand, and the Philippines, while in Malaysia and Singapore UV germicidal connection devices are most popular. However, in all these countries there has been a progressive shift over the last

  17. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  18. What's the Deal with Dialysis?

    Science.gov (United States)

    ... Dialysis Work? Other Options Print Don't you love swimming in a cool, blue pool? Splashing around ... dialysate cleanses the blood and rebalances the blood's chemistry. After about an hour, the machine drains the ...

  19. Toward dialysis "a la carte".

    Science.gov (United States)

    Funck-Brentano, J L

    1987-12-01

    From the very beginning, the artificial kidney postponed the death of patients with end-stage renal failure. For years, owing to the performance of the machine, the patient was obliged to follow a severe diet in order to maintain good humoral and circulatory status. Now technological improvements allow "dialysis à la carte," whereby each individual achieves a better clinical status. The next step will be automation of the procedure to improve its security, mainly for dialysis performed at home.

  20. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy; van Veen, Youri; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is

  1. Needle Decompression in Appalachia Do Obese Patients Need Longer Needles?

    Directory of Open Access Journals (Sweden)

    Carter, Thomas Edward

    2013-11-01

    Full Text Available Introduction: Needle decompression of a tension pneumothorax can be a lifesaving procedure. It requires an adequate needle length to reach the chest wall to rapidly remove air. With adult obesity exceeding one third of the United States population in 2010, we sought to evaluate the proper catheter length that may result in a successful needle decompression procedure. Advance Trauma Life Support (ATLS currently recommends a 51 millimeter (mm needle, while the needles stocked in our emergency department are 46 mm. Given the obesity rates of our patient population, we hypothesize these needles would not have a tolerable success rate of 90%. Methods: We retrospectively reviewed 91 patient records that had computed tomography of the chest and measured the chest wall depth at the second intercostal space bilaterally. Results: We found that 46 mm needles would only be successful in 52.7% of our patient population, yet the ATLS recommended length of 51 mm has a success rate of 64.8%. Therefore, using a 64 mm needle would be successful in 79% percent of our patient population. Conclusion: Use of longer length needles for needle thoracostomy is essential given the extent of the nation’s adult obesity population. [West J Emerg Med. 2013;14(6:650-652.

  2. The dialysis catheter and infectious peritonitis in intermittent peritoneal dialysis

    DEFF Research Database (Denmark)

    Kolmos, Hans Jørn; Hemmeløff Andersen, Karl Erik; Hansen, Lise

    1984-01-01

    118 episodes of infectious peritonitis registered among 156 patients treated with intermittent peritoneal dialysis over a 5-yr period were analysed with special reference to potential routes of infection associated with the dialysis catheter. Peritonitis was randomly distributed among the patients......, and the change of keeping free of peritonitis declined exponentially with time. The main factor determining the individual number of episodes was the total space of time, in which a patient had been wearing a dialysis catheter, whereas the number of catheter disconnections played no significant role. A relative...... preponderance of cases due to Enterobacteriaceae was noted within the first week after catheter implantation. In contrast with this, peritonitis with skin microorganisms was not associated with the implantation of catheters....

  3. Dialysis: Reducing Infections and Changing Culture

    Centers for Disease Control (CDC) Podcasts

    This podcast is an account from an infection preventionist about the challenges and successes with engaging dialysis care teams to focus on "Zero Preventable Infections" in outpatient dialysis facilities.

  4. Treatment Methods for Kidney Failure: Peritoneal Dialysis

    Science.gov (United States)

    ... connect the bags of dialysis solution place the drain tube If you choose automated peritoneal dialysis, you also ... from the new bag of solution into the drain bag. Clamp the tube that goes to the drain bag. Open or ...

  5. (HIV) seropositive Nigerian patients undergoing dialysis

    African Journals Online (AJOL)

    Most dialysis centres in Nigeria currently do not accept HIV positive patients for dialysis therapy for many reasons. The prevailing high level of stigmatization of HIV positive patients and the lack of job security for infected staff are two major reasons for the non-acceptance of HIV infected patients for dialysis by these centres.

  6. Needle bar for warp knitting machines

    Science.gov (United States)

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  7. Needling the early universe

    International Nuclear Information System (INIS)

    Hawkins, I.; Wright, E.L.

    1988-01-01

    The possibility that the whole microwave background can be produced by a bright population of pregalactic stars at a redshift of a few hundred is explored. The radiation is thermalized by a combination of amorphous silicate, amorphous carbon, graphite, and needle-shaped conducting grains which give rise to the opacity needed at wavelengths greater than 3 cm. The occurrence of distortion in a primordial microwave background spectrum due to its interaction with Population III stars and dust is investigated. The possibility of producing deviations small enough to be consistent with the best available observations, but still detectable by COBE, is considered. 65 references

  8. Conflict when making decisions about dialysis modality.

    Science.gov (United States)

    Chen, Nien-Hsin; Lin, Yu-Ping; Liang, Shu-Yuan; Tung, Heng-Hsin; Tsay, Shiow-Luan; Wang, Tsae-Jyy

    2018-01-01

    To explore decisional conflict and its influencing factors on choosing dialysis modality in patients with end-stage renal diseases. The influencing factors investigated include demographics, predialysis education, dialysis knowledge, decision self-efficacy and social support. Making dialysis modality decisions can be challenging for patients with end-stage renal diseases; there are pros and cons to both haemodialysis and peritoneal dialysis. Patients are often uncertain as to which one will be the best alternative for them. This decisional conflict increases the likelihood of making a decision that is not based on the patient's values or preferences and may result in undesirable postdecisional consequences. Addressing factors predisposing patients to decisional conflict helps to facilitate informed decision-making and then to improve healthcare quality. A predictive correlational cross-sectional study design was used. Seventy patients were recruited from the outpatient dialysis clinics of two general hospitals in Taiwan. Data were collected with study questionnaires, including questions on demographics, dialysis modality and predialysis education, the Dialysis Knowledge Scale, the Decision Self-Efficacy scale, the Social Support Scale, and the Decisional Conflict Scale. The mean score on the Decisional Conflict Scale was 29.26 (SD = 22.18). Decision self-efficacy, dialysis modality, predialysis education, professional support and dialysis knowledge together explained 76.4% of the variance in decisional conflict. Individuals who had lower decision self-efficacy, did not receive predialysis education on both haemodialysis and peritoneal dialysis, had lower dialysis knowledge and perceived lower professional support reported higher decisional conflict on choosing dialysis modality. When providing decisional support to predialysis stage patients, practitioners need to increase patients' decision self-efficacy, provide both haemodialysis and peritoneal dialysis

  9. Mosquito inspired medical needles

    DEFF Research Database (Denmark)

    Lenau, Torben Anker; Hesselberg, Thomas; Drakidis, Alexandros Dimitrios

    2017-01-01

    The stinging proboscis in mosquitos have diameters of only 40-100 μm which is much less than the thinnest medical needles and the mechanics of these natural stinging mechanisms have therefore attracted attention amongst developers of injection devises. The mosquito use a range of different...... strategies to lower the required penetration force hence allowing a thinner and less stiff proboscis structure. Earlier studies of the mosquito proboscis insertion strategies have shown how each of the single strategies reduces the required penetration force. The present paper gives an overview...... of the advanced set of mechanisms that allow the mosquito to penetrate human skin and also presents other biological mechanisms that facilitate skin penetration. Results from experiments in a skin mimic using biomimetic equivalents to the natural mechanisms are presented. This includes skin stretching, insertion...

  10. Children of home dialysis patients.

    Science.gov (United States)

    Tsaltas, M O

    1976-12-13

    Fifteen children of six families in which one parent was undergoing home dialysis were examined by the Minnesota Multiphasic Personality Inventory, human figure drawings, and family interviews. All the children were found to be clinically depressed, and two thirds had a history of being referred by teachers to school counselors and psychiatrists for behavioral problems in school. Of these referred children, all showed disorders of psychomotor activity and reduced academic achievement. There was no clear-cut evidence that these children were depressed because of exposure to home dialysis per se. The most disturbed children seemed to be responding to depressed parents or to partial object loss. A controlled, prospective study is planned to clarify this question.

  11. Nutrition and the dialysis prescription.

    Science.gov (United States)

    Chertow, G M; Bullard, A; Lazarus, J M

    1996-01-01

    Malnutrition is common among patients with acute and chronic renal failure. The efficiency of modern dialytic techniques has allowed for more liberal administration of nutrients to patients with renal failure, particularly with regard to protein and amino acids. Protein restriction is not indicated for patients on dialysis, and should be employed cautiously, if at all, in patients with renal insufficiency. The 'nutrition prescription' should be considered a vital part of the comprehensive medical, surgical, and dialytic care provided to patients with renal disease.

  12. Anxiety disorders in dialysis patients

    OpenAIRE

    Novaković Milan

    2007-01-01

    Introduction. Anxiety, as a primary symptom, includes all conditions of indefinite fear and psychic disorders dominated by fear. All dialysis patients suffer from anxiety as an independent phenomenon, or as part of another disease. Material and Methods. This study included 753 patients on chronic hemodialysis in Bosnia and Herzegovina (B&H) in the period 1999-2004. The patients were divided into two groups: the first group included 348 patients with Balkan Endemic Nephropathy (BEN), and t...

  13. Prophylactic dialysis in non-dialysis-dependent patients with renal failure after CABG

    Directory of Open Access Journals (Sweden)

    Roghayyeh Borji

    2014-03-01

    Conclusion: According the results of this study, prophylactic dialysis, before conduct-ing CABG, does not have any significant effect on mortality and other complications. The only exception is lung complications in non-dialysis-dependent patients with renal failure.

  14. Testosterone deficiency in dialysis patients: Differences according to the dialysis techniques

    Directory of Open Access Journals (Sweden)

    Secundino Cigarrán

    2017-09-01

    Conclusions: Circulating testosterone levels in men on dialysis were independently associated with HD technique. It can be concluded that a new factor—namely the dialysis technique—may be associated with falling testosterone levels and the associated loss of muscle mass and inflammation. Further studies are needed to establish whether the dialysis technique itself triggers testosterone elimination.

  15. Protein binding studies with radiolabeled compounds containing radiochemical impurities. Equilibrium dialysis versus dialysis rate determination

    DEFF Research Database (Denmark)

    Honoré, B

    1987-01-01

    The influence of radiochemical impurities in dialysis experiments with high-affinity ligands is investigated. Albumin binding of labeled decanoate (97% pure) is studied by two dialysis techniques. It is shown that equilibrium dialysis is very sensitive to the presence of impurities resulting...

  16. 21 CFR 880.5580 - Acupuncture needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to pierce the skin in the practice of acupuncture. The device consists of a solid, stainless steel needle. The...

  17. Needle Biopsy of the Lung

    Science.gov (United States)

    ... clip. The needle is hollow so it can capture the tissue specimen. There are several types of ... breath, difficulty in catching your breath, rapid pulse (heart rate), sharp chest or shoulder pain with breathing, ...

  18. Needle-free influenza vaccination

    NARCIS (Netherlands)

    Amorij, Jean-Pierre; Hinrichs, Wouter L.J.; Frijlink, Henderik W.; Wilschut, Jan C.; Huckriede, Anke

    2010-01-01

    Vaccination is the cornerstone of influenza control in epidemic and pandemic situations. Influenza vaccines are typically given by intramuscular injection. However, needle-free vaccinations could offer several distinct advantages over intramuscular injections: they are pain-free, easier to

  19. Fabrication of tungsten wire needles

    International Nuclear Information System (INIS)

    Roder, A.

    1983-02-01

    Fine point needles for field emissoin are conventionally produced by electrolytically or chemically etching tungsten wire. Points formed in this manner have a typical tip radius of about 0.5 microns and a cone angle of some 30 degrees. The construction of needle matrix detector chambers has created a need for tungsten needles whose specifications are: 20 mil tungsten wire, 1.5 inch total length, 3 mm-long taper (resulting in a cone angle of about 5 degrees), and 25 micron-radius point (similar to that found on sewing needles). In the process described here for producing such needles, tungsten wire, immersed in a NaOH solution and in the presence of an electrode, is connected first to an ac voltage and then to a dc supply, to form a taper and a point on the end of the wire immersed in the solution. The process parameters described here are for needles that will meet the above specifications. Possible variations will be discussed under each approprite heading

  20. Dialysis: Reducing Infections and Changing Culture

    Centers for Disease Control (CDC) Podcasts

    2018-03-19

    This podcast is an account from an infection preventionist about the challenges and successes with engaging dialysis care teams to focus on “Zero Preventable Infections” in outpatient dialysis facilities.  Created: 3/19/2018 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 3/19/2018.

  1. Update on dialysis economics in the UK.

    Science.gov (United States)

    Sharif, Adnan; Baboolal, Keshwar

    2011-03-01

    The burgeoning population of patients requiring renal replacement therapy contributes a disproportionate strain on National Health Service resources. Although renal transplantation is the preferred treatment modality for patients with established renal failure, achieving both clinical and financial advantages, limitations to organ donation and clinical comorbidities will leave a significant proportion of patients with established renal failure requiring expensive dialysis therapy in the form of either hemodialysis or peritoneal dialysis. An understanding of dialysis economics is essential for both healthcare providers and clinical leaders to establish clinically efficient and cost-effective treatment modalities that maximize service provision. In light of changes to the provision of healthcare funds in the form of "Payment by Results," it is imperative for UK renal units to adopt clinically effective and financially accountable dialysis programs. This article explores the role of dialysis economics and implications for UK renal replacement therapy programs.

  2. Risky business for dialysis services.

    Science.gov (United States)

    Schohl, Joseph

    2010-05-01

    When self-insured health plans and their third-party administrators pay an artificially low out-of-network rate for dialysis services, they could be liable for the difference between that rate and the reimbursement level provided for by their health plan. Paying a rate that the repricers advised them to pay does not relieve self-insured health plans and third-party administrators of that obligation; only where the repricer has legitimately secured a negotiated contract rate is a lower payment justified. [Editor's note: The term "repricer" has no universally-accepted or formal definition, but it will be used here to describe those companies formed to act as middlemen between health care payers-like self-insured employer plans and TPAs working on behalf of such plans-and health care providers.] Failing to adhere to this will result in lawsuits against self-insured health plans and third-party administrators where they will be forced to defend the repricers' recommended payment amounts, while the repricers try to get themselves dismissed. A better option for plan holders and third-party administrators would be to negotiate directly with the dialysis providers and agree upon a mutually acceptable rate.

  3. Adequacy in dialysis: intermittent versus continuous therapies.

    Science.gov (United States)

    Misra, M; Nolph, K D

    2000-01-01

    A vital conceptual difference between intermittent and continuous dialysis therapies is the difference in the relationship between Kt/V urea and dietary protein intake. For a given level of protein intake the intermittent therapies require a higher Kt/V urea due to the reasons mentioned above. The recently released adequacy guidelines by DOQI for intermittent and continuous therapies are based on these assumptions. The link between adequacy targets and patient survival is well documented for an intermittent therapy like HD. For a continuous therapy like CAPD however, the evidence linking improved peritoneal clearance to better survival is not as direct. However, present consensus allows one to extrapolate results based on HD. The concept of earlier and healthier initiation of dialysis is gaining hold and incremental dialysis forms an integral aspect of the whole concept. Tools like urea kinetic modeling give us valuable insight in making mathematical projections about the timing as well as dosing of dialysis. Daily home hemodialysis is still an underutilized modality despite offering best survival figures. Hopefully, with increasing availability of better and simpler machines its use will increase. Still several questions remain unanswered. Despite availability of data in hemodialysis patients suggesting that an increased dialysis prescription leads to a better survival, optimal dialysis dose is yet to be defined. Concerns regarding methodology of such studies and conclusions thereof has been raised. Other issues relating to design of the studies, variation in dialysis delivery, use of uncontrolled historical standards and lack of patient randomization etc also need to be considered when designing such trials. Hopefully an ongoing prospective randomized trial, namely the HEMO study, looking at two precisely defined and carefully maintained dialysis prescriptions will provide some insight into adequacy of dialysis dose and survival. In diabetic patients, the

  4. An Assessment of Dialysis Provider's Attitudes towards Timing of Dialysis Initiation in Canada

    Directory of Open Access Journals (Sweden)

    Bikaramjit S Mann

    2014-04-01

    Full Text Available Background: Physicians' perceptions and opinions may influence when to initiate dialysis. Objective: To examine providers' perspectives and opinions regarding the timing of dialysis initiation. Design: Online survey. Setting: Community and academic dialysis practices in Canada. Participants: A nationally-representative sample of dialysis providers. Measurements and Methods: Dialysis providers opinions assessing reasons to initiate dialysis at low or high eGFR. Responses were obtained using a 9-point Likert scale. Early dialysis was defined as initiation of dialysis in an individual with an eGFR greater than or equal to 10.5 ml/min/m 2 . A detailed survey was emailed to all members of the Canadian Society of Nephrology (CSN in February 2013. The survey was designed and pre-tested to evaluate duration and ease of administration. Results: One hundred and forty one (25% response rate physicians participated in the survey. The majority were from urban, academic centres and practiced in regionally administered renal programs. Very few respondents had a formal policy regarding the timing of dialysis initiation or formally reviewed new dialysis starts (N = 4, 3.1%. The majority of respondents were either neutral or disagreed that late compared to early dialysis initiation improved outcomes (85–88%, had a negative impact on quality of life (89%, worsened AVF or PD use (84–90%, led to sicker patients (83% or was cost effective (61%. Fifty-seven percent of respondents felt uremic symptoms occurred earlier in patients with advancing age or co-morbid illness. Half (51.8% of the respondents felt there was an absolute eGFR at which they would initiate dialysis in an asymptomatic patient. The majority of respondents would initiate dialysis for classic indications for dialysis, such as volume overload (90.1% and cachexia (83.7% however a significant number chose other factors that may lead them to early dialysis initiation including avoiding an emergency (28

  5. EUS Needle Identification Comparison and Evaluation study (with videos)

    DEFF Research Database (Denmark)

    Tang, Shou-Jiang; Vilmann, Andreas S; Saftoiu, Adrian

    2016-01-01

    Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition (Cook Medical); ClearView (Conmed); EZ Shot 2 (Olympus); and BNX (Beacon Endoscopic), and 2 new prototype needles, SonoCoat (Medi-Globe), coated by echogenic polymers made by Encapson...

  6. Being-in-dialysis: The experience of the machine-body for home dialysis users.

    Science.gov (United States)

    Shaw, Rhonda

    2015-05-01

    New Zealand leads the world in rates of home dialysis use, yet little is known about the experience of home dialysis from the patient's perspective. This article contributes to the literature on the self-care of dialysis patients by examining the relevance of the concept of the machine-body and cyborg embodiment for the lived experience of people with end-stage renal failure. The article, which presents a discussion of 24 in-depth interviews undertaken between 2009 and 2012, shows that although dialysis therapy is disruptive of being and time, study participants experience home dialysis in terms of flexibility, control and independence. While they do not use the term machine-body as a descriptor, the concept resonates with felt experience. Data also indicate that positive experience of home dialysis is relative to socio-economic positioning and the lived relation of patients to others, necessitating further research to examine these factors. © The Author(s) 2014.

  7. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  8. Processing and Characterization of Needled Carbon Composites

    Science.gov (United States)

    2015-12-01

    needle is used to insert high strength yarns (i.e., threads) through the dry fabric or prepreg laminate , leaving a loose thread loop underneath [9-11...capability which uses commercially-available felting needles to insert z-fibers into composite laminates at different angles (±45/90°) relative to the... laminate plane. Previous work with needled glass/epoxy composites has shown a 270% improvement in Mode I interlaminar fracture toughness when needled

  9. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  10. Are Diuretics Underutilized in Dialysis Patients?

    Science.gov (United States)

    Trinh, Emilie; Bargman, Joanne M

    2016-09-01

    While oral diuretics are commonly used in patients with chronic kidney disease for the management of volume and blood pressure, they are often discontinued upon initiation of dialysis. We suggest that diuretics are considerably underutilized in peritoneal dialysis and haemodialysis patients despite numerous potential benefits and few side effects. Moreover, when diuretics are used, optimal doses are not always prescribed. In peritoneal dialysis, the use of diuretics can improve volume status and minimize the need for higher glucose-containing solutions. In patients on haemodialysis, diuretics can help lessen interdialytic weight gain, resulting in decreased ultrafiltration rates and fewer episodes of intradialytic hypotension. This paper will review the mechanism of action of diuretics in patients with renal insufficiency, quantify the risk of side effects and elaborate on the potential advantages of diuretic use in peritoneal dialysis and hemodialysis patients with residual kidney function. © 2016 Wiley Periodicals, Inc.

  11. Collagen markers in peritoneal dialysis patients

    DEFF Research Database (Denmark)

    Graff, J; Joffe, P; Fugleberg, S

    1995-01-01

    Possible relationships between the dialysate-to-plasma creatinine equilibration ratio (D/Pcreatinine 4 hour), duration of peritoneal dialysis treatment, number of peritonitis episodes, and mass appearance rates of three connective tissue markers [carboxyterminal propeptide of type I procollagen...... (PICP), aminoterminal propeptide of type III procollagen (PIIINP), and carboxyterminal telopeptide of type I collagen (ICTP)] were studied in 19 nondiabetic peritoneal dialysis patients. The absence of correlation between the mass appearance rates of the markers and the duration of dialysis treatment...... as well as the number of peritonitis episodes supports the concept that peritoneal dialysis does not cause persistent changes in the deposition and degradation rates of collagen. A correlation between the D/Pcreatinine 4 hr and the PICP mass appearance rates was found. Since it is unlikely...

  12. Dialysis: MedlinePlus Health Topic

    Science.gov (United States)

    ... access for hemodialysis (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Dialysis updates by ... for hemodialysis Show More Show Less Related Health Topics Creatinine Kidney Cysts Kidney Failure Peritoneal Disorders National ...

  13. Relations between Scots pine needle element concentrations and decreased needle longevity along pollution gradients

    International Nuclear Information System (INIS)

    Lamppu, Jukka; Huttunen, Satu

    2003-01-01

    Deceased needle longevity was related to increased heavy metal concentrations. - Scots pine (Pinus sylvestris L.) shoots were sampled along transects near one urban pollution source and two smelters. Needle Mg, P and K concentrations decreased from the second to the fourth age class linearly with needle survival along the urban pollution gradient. Still, over 80% of the average concentration of these nutrients remained in the fourth needle age class. Decreased needle longevity was closely related to the increased heavy metal concentrations near the smelters. Near the urban pollution source, it was related to the increased annual needle mass and the increased needle nutrient concentrations. Decreased Mn accumulation along with needle age was detected near all pollution sources. Leaching of Mn from needles and especially from soil as a cause of decreased needle concentrations is discussed

  14. Intraperitoneal pressure in peritoneal dialysis

    Directory of Open Access Journals (Sweden)

    Vicente Pérez Díaz

    2017-11-01

    Full Text Available The measure of intraperitoneal pressure in peritoneal dialysis is easy and provides clear therapeutic benefits. However it is measured only rarely in adult peritoneal dialysis units. This review aims to disseminate the usefulness of measuring intraperitoneal pressure. This measurement is performed in supine before initiating the drain of a manual exchange with “Y” system, by raising the drain bag and measuring from the mid-axillary line the height of the liquid column that rises from the patient. With typical values of 10–16 cm H2O, intraperitoneal pressure should never exceed 18 cm H2O. With basal values that depend on body mass index, it increases 1–3 cm H2O/L of intraperitoneal volume, and varies with posture and physical activity. Its increase causes discomfort, sleep and breathing disturbances, and has been linked to the occurrence of leaks, hernias, hydrothorax, gastro-esophageal reflux and enteric peritonitis. Less known and valued is its ability to decrease the effectiveness of dialysis significantly counteracting ultrafiltration and decreasing solute clearance to a smaller degree. Because of its easy measurement and potential utility, should be monitored in case of ultrafiltration failure to rule out its eventual contribution in some patients. Although not yet mentioned in the clinical practice guidelines for PD, its clear benefits justify its inclusion among the periodic measurements to consider for prescribing and monitoring peritoneal dialysis. Resumen: La medida de la presión intraperitoneal en diálisis peritoneal es muy sencilla y aporta claros beneficios terapéuticos. Sin embargo, su monitorización todavía no se ha generalizado en las unidades de diálisis peritoneal de adultos. Esta revisión pretende divulgar su conocimiento y la utilidad de su medida. Se realiza en decúbito antes de iniciar el drenaje de un intercambio manual con bolsa en Y, elevando la bolsa de

  15. Peritoneal Dialysis in Western Countries.

    Science.gov (United States)

    Struijk, Dirk G

    2015-12-01

    Peritoneal dialysis (PD) for the treatment of end-stage renal failure was introduced in the 1960s. Nowadays it has evolved to an established therapy that is complementary to hemodialysis (HD), representing 11% of all patients treated worldwide with dialysis. Despite good clinical outcomes and similar results in patient survival between PD and HD, the penetration of PD is decreasing in the Western world. First the major events in the history of the development of PD are described. Then important insights into the physiology of peritoneal transport are discussed and linked to the changes in time observed in biopsies of the peritoneal membrane. Furthermore, the developments in peritoneal access, more biocompatible dialysate solutions, automated PD at home, the establishment of parameters for dialysis adequacy and strategies to prevent infectious complications are mentioned. Finally non-medical issues responsible for the declining penetration in the Western world are analyzed. Only after introduction of the concept of continuous ambulatory PD by Moncrief and Popovich has this treatment evolved in time to a renal replacement therapy. Of all structures present in the peritoneal membrane, the capillary endothelium offers the rate-limiting hindrance for solute and water transport for the diffusive and convective transport of solutes and osmosis. The functional and anatomical changes in the peritoneal membrane in time can be monitored by the peritoneal equilibrium test. Peritonitis incidence decreased by introduction of the Y-set and prophylaxis using mupirocin on the exit site. The decrease in the proportion of patients treated with PD in the Western world can be explained by non-medical issues such as inadequate predialysis patient education, physician experience and training, ease of HD initiation, overcapacity of in-center HD, lack of adequate infrastructure for PD treatment, costs and reimbursement issues of the treatment. (1) PD is cheaper than HD and provides a

  16. Polymer films

    Science.gov (United States)

    Granick, Steve; Sukhishvili, Svetlana A.

    2004-05-25

    A film contains a first polymer having a plurality of hydrogen bond donating moieties, and a second polymer having a plurality of hydrogen bond accepting moieties. The second polymer is hydrogen bonded to the first polymer.

  17. Synthesis and Characterization of Pine Needles Reinforced RF Matrix Based Biocomposites

    Directory of Open Access Journals (Sweden)

    A. S. Singha

    2008-01-01

    Full Text Available Synthesis and characterization of pine needles reinforced thermosetting resin (Resorcinol-Formaldehyde which is most suitable as composite matrix has been reported. The polycondensation reaction between resorcinol and formaldehyde (RF in different molar ratios has been applied to the synthesis of RF polymer matrix. A thermosetting resin based composite, containing approximately 10, 20, 30 and 40% of natural fiber by weight, has been obtained by adding pine needles to the Resorcinol-Formaldehyde (RF resin. The mechanical properties of randomly oriented intimately mixed particle reinforced (Pine needles composites were determined. Effect of fiber loading in terms of weight % on mechanical properties such as tensile, compressive, and flexural and wear properties have also been evaluated. The reinforcing of the resin with Pine needles was accomplished in particle size of 200 micron by employing optimized resin. Present work reveals that mechanical properties of the RF resin increases to extensive extent when reinforced with Pine needles. Thermal (TGA/DTA and morphological studies (SEM of the resin, fiber and polymer composites thus synthesized have also been carried out.

  18. Restless legs syndrome in patients on dialysis

    International Nuclear Information System (INIS)

    AlJahdali, Hamdan H; AlQadhi, Waleed A; Khogeer, Haithm A; AlHejaili, Fayez F; Al Sayyari, Abdullah A; AlGhamdi, Saeed M

    2009-01-01

    Restless legs syndrome (RLS) is an extremely distressing problem experienced by patients on dialysis; the prevalence appears to be greater than in the general population, with a wide variation from 6.6% to 80%. The diagnosis of RLS is a clinical one, and its definition has been clarified and standardized by internationally recognized diagnostic criteria, published in 1995 by the International Restless Legs Syndrome Study Group (IRLSSG). This study was designed to find out the prevalence of RLS in Saudi patients with end-stage renal disease (ESRD) on maintenance dialysis. This is a cross sectional study carried out between May and Sept 2007 at two centers, King Abdulaziz Medical City-King Fahad National Guard Hospital (KAMC-KFNGH), Riyadh and King Faisal Specialist Hospital and Research Centre (KFHRC), Jeddah, Saudi Arabia. Data were gathered on 227 Saudi patients on chronic maintenance hemodialysis or chronic peritoneal dialysis. The prevalence of RLS was measured using IRLSSG's RLS Questionnaire (RLSQ). Potential risk factors for RLS including other sleep disorders, underlying cause of chronic renal failure, duration on dialysis, dialysis shift, biochemical tests and demographic data were also evaluated. The overall prevalence of RLS was 50.22% including 53.7% males and 46.3% females. Their mean age was 55.7 + - 17.2 years and mean duration on dialysis 40.4 + - 37.8 months. Significant predictors of RLS were history of diabetes mellitus (DM), coffee intake, afternoon dialysis, gender and type of dialysis (P= 0.03, 0.01, < 0.001, 0.05 and 0.009 respectively). Patients with RLS were found to be at increased risk of having insomnia and excessive daytime sleepiness (EDS) (P= < 0.001 and 0.001, respectively). Our study suggests that RLS is a very common problem in dialysis population and was significantly associated with other sleep disorders, particularly insomnia, and EDS. Optimal care of dialysis patient should include particular attention to the diagnosis and

  19. Restless legs syndrome in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Al-Jahdali Hamdan

    2009-01-01

    Full Text Available Restless legs syndrome (RLS is an extremely distressing problem experienced by patients on dialysis; the prevalence appears to be greater than in the general population, with a wide variation from 6.6% to 80%. The diagnosis of RLS is a clinical one, and its definition has been clarified and standardized by internationally recognized diagnostic criteria, published in 1995 by the International Restless Legs Syndrome Study Group (IRLSSG. This study was designed to find out the prevalence of RLS in Saudi patients with end-stage renal disease (ESRD on maintenance dialysis. This is a cross sectional study carried out between May and Sept 2007 at two centers, King Abdulaziz Medical City-King Fahad National Guard Hospital (KAMC-KFNGH, Riyadh and King Faisal Specialist Hospital and Research Centre (KFHRC, Jeddah, Saudi Arabia. Data were gathered on 227 Saudi patients on chronic maintenance hemodialysis or chronic peritoneal dialysis. The prevalence of RLS was measured using IRLSSG′s RLS Questionnaire (RLSQ. Potential risk factors for RLS including other sleep disorders, underlying cause of chronic renal failure, duration on dialysis, dialysis shift, biochemical tests and demographic data were also evaluated. The overall prevalence of RLS was 50.22% including 53.7% males and 46.3% females. Their mean age was 55.7 ± 17.2 years and mean duration on dialysis 40.4 ± 37.8 months. Significant predictors of RLS were history of diabetes mellitus (DM, coffee intake, afternoon dialysis, gender and type of dialysis (P= 0.03, 0.01, < 0.001, 0.05 and 0.009 respectively. Patients with RLS were found to be at increased risk of having insomnia and excessive daytime sleepiness (EDS (P= < 0.001 and 0.001, respectively. Our study suggests that RLS is a very common problem in dialysis population and was significantly associated with other sleep disorders, particularly insomnia, and EDS. Optimal care of dialysis patient should include particular attention to the diagnosis

  20. Brachytherapy needle deflection evaluation and correction

    International Nuclear Information System (INIS)

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively

  1. Smart surgical needle actuated by shape memory alloys for percutaneous procedures

    Science.gov (United States)

    Konh, Bardia

    . Design parameters influencing the steerability include the needle's diameter, wire diameter, pre-strain, and its offset from the needle. A simplified model was developed to decrease the computation time in iterative analyses of the optimization algorithm. In the fourth part of this work a design of an active needling system was proposed where actuation forces of SMAs as well as shape memory polymers (SMPs) were incorporated. SMP elements provide two major additional advantages to the design: (i) recovery of the SMP's plastic deformation by heating the element above its glass transition temperature, and (ii) achieving a higher needle deflection by having a softer stage of SMP at higher temperatures with less amount of actuation force. Finally, in the fifth and last part of this study, an Arbitrary-Lagrangian-Eulerian formulation in LS-DYNA software was used to model the solid-fluid interactions between the needle and tissue. A 150mm long needle was considered to bend within the tissue due to the interacting forces on its asymmetric bevel tip. Some additional assumptions were made to maintain a reasonable computational time, with no need of parallel processing, while having practical accuracies. Three experimental tests of needle steering in a soft phantom were performed to validate the simulation. Results: The finite element model of the active needle was first validated experimentally with developed prototypes. Several design parameters affecting the needle's deflection such as the needle's Young's modulus, the SMA's pre-strain and its offset from the neutral axis of the cannula were studied using the FE model. Then by the integration of the SMA characteristics with the automated optimization schemes an improved design of the active needle was obtained. Real-time experiments with different prototypes showed that the quickest response and the maximum deflection were achieved by the needle with two sections of actuation compared to a single section of actuation. Also the

  2. Tattoo machines, needles and utilities.

    Science.gov (United States)

    Rosenkilde, Frank

    2015-01-01

    Starting out as a professional tattooist back in 1977 in Copenhagen, Denmark, Frank Rosenkilde has personally experienced the remarkable development of tattoo machines, needles and utilities: all the way from home-made equipment to industrial products of substantially improved quality. Machines can be constructed like the traditional dual-coil and single-coil machines or can be e-coil, rotary and hybrid machines, with the more convenient and precise rotary machines being the recent trend. This development has resulted in disposable needles and utilities. Newer machines are more easily kept clean and protected with foil to prevent crosscontaminations and infections. The machines and the tattooists' knowledge and awareness about prevention of infection have developed hand-in-hand. For decades, Frank Rosenkilde has been collecting tattoo machines. Part of his collection is presented here, supplemented by his personal notes. © 2015 S. Karger AG, Basel.

  3. Performance measures for a dialysis setting.

    Science.gov (United States)

    Gu, Xiuzhu; Itoh, Kenji

    2018-03-01

    This study from Japan extracted performance measures for dialysis unit management and investigated their characteristics from professional views. Two surveys were conducted using self-administered questionnaires, in which dialysis managers/staff were asked to rate the usefulness of 44 performance indicators. A total of 255 managers and 2,097 staff responded. Eight performance measures were elicited from dialysis manager and staff responses: these were safety, operational efficiency, quality of working life, financial effectiveness, employee development, mortality, patient/employee satisfaction and patient-centred health care. These performance measures were almost compatible with those extracted in overall healthcare settings in a previous study. Internal reliability, content and construct validity of the performance measures for the dialysis setting were ensured to some extent. As a general trend, both dialysis managers and staff perceived performance measures as highly useful, especially for safety, mortality, operational efficiency and patient/employee satisfaction, but showed relatively low concerns for patient-centred health care and employee development. However, dialysis managers' usefulness perceptions were significantly higher than staff. Important guidelines for designing a holistic hospital/clinic management system were yielded. Performance measures must be balanced for outcomes and performance shaping factors (PSF); a common set of performance measures could be applied to all the healthcare settings, although performance indicators of each measure should be composed based on the application field and setting; in addition, sound causal relationships between PSF and outcome measures/indicators should be explored for further improvement. © 2017 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  4. Remote Patient Management for Home Dialysis Patients

    Directory of Open Access Journals (Sweden)

    Eric L. Wallace

    2017-11-01

    Full Text Available Remote patient management (RPM offers renal health care providers and patients with end-stage kidney disease opportunities to embrace home dialysis therapies with greater confidence and the potential to obtain better clinical outcomes. Barriers and evidence required to increase adoption of RPM by the nephrology community need to be clearly defined. Ten health care providers from specialties including nephrology, cardiology, pediatrics, epidemiology, nursing, and health informatics with experience in home dialysis and the use of RPM systems gathered in Vienna, Austria to discuss opportunities for, barriers to, and system requirements of RPM as it applies to the home dialysis patient. Although improved outcomes and cost-effectiveness of RPM have been demonstrated in patients with diabetes mellitus and heart disease, only observational data on RPM have been gathered in patients on dialysis. The current review focused on RPM systems currently in use, on how RPM should be integrated into future care, and on the evidence needed for optimized implementation to improve clinical and economic outcomes. Randomized controlled trials and/or large observational studies could inform the most effective and economical use of RPM in home dialysis. These studies are needed to establish the value of existing and/or future RPM models among patients, policy makers, and health care providers.

  5. Needle-Stick Injury among Health Care Workers in Hemodialysis Units in Nigeria: A Multi-Center Study

    Directory of Open Access Journals (Sweden)

    CO Amira

    2014-01-01

    Full Text Available Background: Needle-stick and sharps injuries carry the risk of infection and are occupational hazards for all health care professionals involved in clinical care. Objective: To determine the frequency and factors contributing to needle-stick injury (NSI among health care workers of dialysis units in Lagos, Nigeria. Methods: Data were obtained by anonymous, self-reporting questionnaire from staff of 4 hemodialysis units between October and December 2011. Information on demographics, job category and duration, details of NSI in the past, kind of activity and procedure under which the NSI occurred, if injury was reported, vaccination status of staff, and post-exposure treatment received were obtained. Results: The study population included 38 (37.3% doctors, 42 nurses (41.2%, 14 (13.7% dialysis technicians and 8 (7.8% ancillary staff. There were 39 (38.2% males. The mean±SD age of the study population was 34.4±8.3 years. 25 (24.5% staff had suffered NSI in the last 12 months and 41 (40.2% in their entire working career. The most common activity leading to NSI was recapping of needles (45%, improper disposal of needles (30%, and venous cannulation and setting of drips (27.5%. NSI was significantly (p=0.016 higher among those with work experience between 6 and 10 years than others. Hollow bore needles were responsible for 82.9% of the NSIs. Only 15 (37% respondents reported their NSI to their unit head or designated officer in order to get medical advice. Conclusion: In Lagos, Nigeria, NSI is common among hemodialysis staff and is under-reported. Many NSIs can be prevented by adhering to the practice of universal precautions as well as education of staff on such precautionary methods.

  6. Facile fabrication of super-hydrophobic nano-needle arrays via breath figures method.

    Science.gov (United States)

    Kim, Jiseok; Lew, Brian; Kim, Woo Soo

    2011-12-06

    Super-hydrophobic surfaces which have been fabricated by various methods such as photolithography, chemical treatment, self-assembly, and imprinting have gained enormous attention in recent years. Especially 2D arrays of nano-needles have been shown to have super-hydrophobicity due to their sharp surface roughness. These arrays can be easily generated by removing the top portion of the honeycomb films prepared by the breath figures method. The hydrophilic block of an amphiphilic polymer helps in the fabrication of the nano-needle arrays through the production of well-ordered honeycomb films and good adhesion of the film to a substrate. Anisotropic patterns with water wettability difference can be useful for patterning cells and other materials using their selective growth on the hydrophilic part of the pattern. However, there has not been a simple way to generate patterns with highly different wettability. Mechanical stamping of the nano-needle array with a polyurethane stamp might be the simplest way to fabricate patterns with wettability difference. In this study, super-hydrophobic nano-needle arrays were simply fabricated by removing the top portion of the honeycomb films. The maximum water contact angle obtained with the nano-needle array was 150°. By controlling the pore size and the density of the honeycomb films, the height, width, and density of nano-needle arrays were determined. Anisotropic patterns with different wettability were fabricated by simply pressing the nano-needle array at ambient temperature with polyurethane stamps which were flexible but tough. Mechanical stamping of nano-needle arrays with micron patterns produced hierarchical super-hydrophobic structures.PACS: 05.70.Np, 68.55.am, 68.55.jm.

  7. Administration of calcimimetics after dialysis: Same effectiveness, better gastrointestinal tolerability

    Directory of Open Access Journals (Sweden)

    Vicent Esteve Simo

    2015-07-01

    Conclusions: Post-dialysis use of calcimimetic was effective in secondary hyperparathyroidism control, improved gastrointestinal tolerability and ameliorated patients’ satisfaction. Based on our findings, post-dialysis use of calcimimetics should be considered in selected patients with low therapeutic compliance.

  8. Clostridium difficile-associated diarrhea in dialysis patients

    Directory of Open Access Journals (Sweden)

    Sook Eui Oh

    2013-03-01

    Conclusion: Our data indicate that dialysis patients might be at a greater risk of developing CDAD, which suggests that particular attention should be provided to CDAD when antibiotic treatment is administered to dialysis patients.

  9. Non-machinery dialysis that achieves blood purification therapy without using full-scale dialysis machines.

    Science.gov (United States)

    Abe, Takaya; Onoda, Mistutaka; Matsuura, Tomohiko; Sugimura, Jun; Obara, Wataru; Sato, Toshiya; Takahashi, Mihoko; Chiba, Kenta; Abe, Tomiya

    2017-09-01

    An electrical or water supply and a blood purification machine are required for renal replacement therapy. There is a possibility that acute kidney injury can occur in large numbers and on a wide scale in the case of a massive earthquake, and there is the potential risk that the current supply will be unable to cope with acute kidney injury cases. However, non-machinery dialysis requires exclusive circuits and has the characteristic of not requiring the full-scale dialysis machines. We performed perfusion experiments that used non-machinery dialysis and recent blood purification machines in 30-min intervals, and the effectiveness of non-machinery dialysis was evaluated by the assessing the removal efficiency of potassium, which causes lethal arrhythmia during acute kidney injury. The non-machinery dialysis potassium removal rate was at the same level as continuous blood purification machines with a dialysate flow rate of 5 L/h after 15 min and continuous blood purification machines with a dialysate flow rate of 3 L/h after 30 min. Non-machinery dialysis required an exclusive dialysate circuit, the frequent need to replace bags, and new dialysate exchanged once every 30 min. However, it can be seen as an effective renal replacement therapy for crush-related acute kidney injury patients, even in locations or facilities not having the full-scale dialysis machines.

  10. Nutritional status of maintenance dialysis patients

    DEFF Research Database (Denmark)

    Koefoed, Mette Juul; Kromann, Charles Boy; Juliussen, Sophie Ryberg

    2016-01-01

    Background and Aims Maintenance dialysis patients are at increased risk of abnormal nutritional status due to numerous causative factors, both nutritional and non-nutritional. The present study assessed the current prevalence of protein-energy wasting, low lean bodymass index and obesity...... protein catabolic rate in order to assess the prevalence of protein-energy wasting, low lean body mass index and obesity in these patients. Results Seventy-nine eligible maintenance dialysis patients participated. The prevalence of proteinenergy wasted patients was 4%(95%CI: 2-12) as assessed......-energy wasting and obesity varied considerably, depending on nutritional assessment methodology. Conclusions Our data indicate that protein-energy wasting is uncommon, whereas low lean body mass index and obesity are frequent conditions among patients in maintenance dialysis. A focus on how to increase...

  11. Cardiovascular and noncardiovascular mortality among men and women starting dialysis

    DEFF Research Database (Denmark)

    Carrero, Juan J; de Jager, Dinanda J; Verduijn, Marion

    2011-01-01

    Although women have a survival advantage in the general population, women on dialysis have similar mortality to men. We hypothesized that this paired mortality risk during dialysis may be explained by a relative excess of cardiovascular-related mortality in women.......Although women have a survival advantage in the general population, women on dialysis have similar mortality to men. We hypothesized that this paired mortality risk during dialysis may be explained by a relative excess of cardiovascular-related mortality in women....

  12. Optimizing home dialysis: role of hemodiafiltration.

    Science.gov (United States)

    Vilar, Enric; Farrington, Ken; Bates, Chris; Mumford, Carol; Greenwood, Roger

    2011-01-01

    Over the last 40 years the technical obstacles which prevented a convective contribution to diffusive dialysis have been overcome. Hemodiafiltration represents a natural evolution of intermittent extracorporeal blood purification and the technology is now available to offer this as standard treatment in-center. The first randomized control trial of dialysis dose (National Cooperative Dialysis Study) showed that for three times weekly dialysis a critical level of urea clearance was necessary to ensure complication-free survival, the effect being noticeable by 3 months. Following this, observational studies suggested that higher doses improved longer term outcome. In a second large randomized controlled study (HEMO), higher small molecule clearance did not further improve outcome, but high-flux membranes, which permitted enhanced clearance of middle molecules, appeared to confer survival benefit in patients who had already been on dialysis > 3.7 years. Recently, outcomes from the Membrane Permeability Outcome study confirmed a survival benefit of high-flux membranes in high-risk patients. These studies indicate that in the medium term survival is critically dependent on achieving a minimum level of small solute removal. However, longer term survival (measured in years or decades) not only requires better small solute clearance but also enhanced clearance of middle molecules, the toxicity of which manifest over longer time scales. The rationale for convective treatment is strongest, therefore in those patients who have the greatest potential for long-term survival. Patients who opt for self-care at home to allow frequent dialysis generally are constituents of this group. Hemodiafiltration is likely to become standard therapy in-center and in the home. Copyright © 2011 S. Karger AG, Basel.

  13. Acute hydrothorax from peritoneal dialysis successfully treated with new dialysis regime

    International Nuclear Information System (INIS)

    Lim, C.T.S.; Thong, K.M.

    2015-01-01

    Hydrothorax is a rare and often unrecognized complication associated with peritoneal dialysis (PD). This is usually due to the presence of pleuroperitoneal fistula. Most nephrologist will choose to cease the peritoneal dialysis and rest the peritoneum. More than often surgical interventions include pleurodesis or thoracotomy will be required. In this report, we reported a patient who developed pleural effusion after starting continuous ambulatory peritoneal dialysis. She was successfully managed by the use of low volume exchange during daytime with avoidance of conversion to haemodialysis or any surgical intervention. (author)

  14. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  15. Australian consumer perspectives on dialysis: first national census.

    Science.gov (United States)

    Ludlow, Marie J; Lauder, Lydia A; Mathew, Timothy H; Hawley, Carmel M; Fortnum, Debbie

    2012-11-01

    The percentage of people in Australia who undertake home dialysis has steadily decreased over the past 40 years and varies within Australia. Consumer factors related to this decline have not previously been determined. A 78-question survey was developed and piloted in 2008 and 2009. Survey forms were distributed to all adult routine dialysis patients in all Australian states and territories (except Northern Territory) between 2009 and 2010. Of 9223 distributed surveys, 3250 were completed and returned. 49% of respondents indicated they had no choice in the type of dialysis and 48% had no choice in dialysis location. Respondents were twice as likely to receive information about haemodialysis (85%) than APD (39%) or CAPD (41%). The provision of education regarding home modalities differed significantly between states, and decreased with increasing patient age. Additional nursing support and reimbursement of expenses increased the proportion of those willing to commence dialysis at home, from 13% to 34%. State differences in the willingness to consider home dialysis, the degree of choice in dialysis location, the desire to change current dialysis type and/or location, and the provision of information about dialysis were identified. The delivery of pre-dialysis education is variable, and does not support all options of dialysis for all individuals. State variances indicate that local policy and health professional teams significantly influence the operation of dialysis programs. © 2012 The Authors. Nephrology © 2012 Asian Pacific Society of Nephrology.

  16. Quality of life in automated and continuous ambulatory peritoneal dialysis

    NARCIS (Netherlands)

    Michels, Wieneke M.; van Dijk, Sandra; Verduijn, Marion; le Cessie, Saskia; Boeschoten, Elisabeth W.; Dekker, Friedo W.; Krediet, Raymond T.; Apperloo, A. J.; Bijlsma, J. A.; Boekhout, M.; Boer, W. H.; van der Boog, P. J. M.; Büller, H. R.; van Buren, M.; de Charro, F. Th; Doorenbos, C. J.; van den Dorpel, M. A.; van Es, A.; Fagel, W. J.; Feith, G. W.; de Fijter, C. W. H.; Frenken, L. A. M.; Grave, W.; van Geelen, J. A. C. A.; Gerlag, P. G. G.; Gorgels, J. P. M. C.; Huisman, R. M.; Jager, K. J.; Jie, K.; Koning-Mulder, W. A. H.; Koolen, M. I.; Kremer Hovinga, T. K.; Lavrijssen, A. T. J.; Luik, A. J.; van der Meulen, J.; Parlevliet, K. J.; Raasveld, M. H. M.; van der Sande, F. M.; Schonck, M. J. M.; Schuurmans, M. M. J.; Siegert, C. E. H.; Stegeman, C. A.; Stevens, P.; Thijssen, J. G. P.; Valentijn, R. M.; Vastenburg, G. H.; Verburgh, C. A.; Vincent, H. H.; Vos, P. F.

    2011-01-01

    Despite a lack of strong evidence, automated peritoneal dialysis (APD) is often prescribed on account of an expected better quality of life (QoL) than that expected with continuous ambulatory peritoneal dialysis (CAPD). Our aim was to analyze differences in QoL in patients starting dialysis on APD

  17. Dialysis-associated steal syndrome (DASS).

    Science.gov (United States)

    Mohamed, Ahmed S; Peden, Eric K

    2017-03-06

    In this article, we will review the clinical symptoms of dialysis access steal syndrome (DASS), evaluation, treatment options, and our approach and treatment algorithm. We reviewed the literature discussing different aspects of DASS including its epidemiology, pathogenesis, clinical presentation, evaluation and management options. DASS is the most dreaded complication of access surgery. Although the incidence is low, all providers caring for dialysis patients should be aware of this problem. Symptoms can range from mild to limb threatening. Although various tests are available, the diagnosis of DASS remains a clinical one and requires thoughtful management to have the best outcomes. Multiple treatment options exist for steal. We present diagnostic evaluation and management algorithm.

  18. Wearable impedance monitoring system for dialysis patients.

    Science.gov (United States)

    Bonnet, S; Bourgerette, A; Gharbi, S; Rubeck, C; Arkouche, W; Massot, B; McAdams, E; Montalibet, A; Jallon, P

    2016-08-01

    This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis.

  19. Dialysis-related amyloidosis: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Scarpioni R

    2016-12-01

    Full Text Available R Scarpioni, M Ricardi, V Albertazzi, S De Amicis, F Rastelli, L Zerbini Department of Nephrology and Dialysis, Azienda Unità Sanitaria Local (AUSL Hospital “Guglielmo da Saliceto”, Piacenza, Italy Abstract: Amyloidosis refers to the extracellular tissue deposition of fibrils composed of low-molecular-weight subunits of a variety of proteins. These deposits may result in a wide range of clinical manifestations depending upon their type, location, and the amount of deposition. Dialysis-related amyloidosis is a serious complication of long-term dialysis therapy and is characterized by the deposition of amyloid fibrils, principally composed of β2 microglobulins (β2M, in the osteoarticular structures and viscera. Most of the β2M is eliminated through glomerular filtration and subsequent reabsorption and catabolism by the proximal tubules. As a consequence, the serum levels of β2M are inversely related to the glomerular filtration rate; therefore, in end-stage renal disease patients, β2M levels increase up to 60-fold. Serum levels of β2M are also elevated in several pathological conditions such as chronic inflammation, liver disease, and above all, in renal dysfunction. Retention of amyloidogenic protein has been attributed to several factors including type of dialysis membrane, prolonged uremic state and/or decreased diuresis, advanced glycation end products, elevated levels of cytokines and dialysate. Dialysis treatment per se has been considered to be an inflammatory stimulus, inducing cytokine production (such as interleukin-1, tumor necrosis factor-α, interleukin-6 and complement activation. The released cytokines are thought to stimulate the synthesis and release of β2M by the macrophages and/or augment the expression of human leukocyte antigens (class I, increasing β2M expression. Residual renal function is probably the best determinant of β2M levels. Therefore, it has to be maintained as long as possible. In this article

  20. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  1. Experiences with a new breast localisation needle

    International Nuclear Information System (INIS)

    Hergan, K.; Amann, T.; Doringer, W.; Hollenstein, P.

    1990-01-01

    In view of the increasing number of biopsies of non-palpable lesions of the female breast we found an ideal localisation system in the Hawkins breast localisation needle. Localisation was successful without technical problems in 31 out of 34 patients. The special advantages of the needle are its stability in position and excellent manoeverability due to the construction of the needle. The very simple handling of the needle is an advantage not only for the radiologist but also for the surgeon. (orig.) [de

  2. Migration of innumerable chronically retained acupuncture needles

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2017-09-01

    Full Text Available We present a case of a 50-year-old female with a 2-day history of back and abdominal pain who was discovered to have innumerable chronically retained acupuncture needles, which had migrated throughout her abdomen and pelvis. Although many of these needles were in precarious positions, including the epidural space, renal parenchyma, small bowel, and vasculature, there was no evidence for acute injury. We also briefly discuss evidence for the magnetic resonance imaging compatibility of acupuncture needles. Although a rare complication, given the high frequency of acupuncture therapy in the United States, physicians must be aware of the potential for retained and migrated needles.

  3. How needless are Buffon's needles?

    International Nuclear Information System (INIS)

    Babović, Miloš; Babović, Vukota

    2013-01-01

    The study of statistical physics requires introductory preparation regarding probability theory. Understanding its fundamental concepts (randomness, distributions, fluctuations), and some experience in application of the basic concepts of statistics can be obtained in several ways. We found that the basic training in probability and statistics needed for physics and engineering study can be achieved by focusing on Buffon's needle problem. We believe this approach could help university specialists make study more efficient when probability and statistics play an important role. Buffon's experiment, with its convincing simplicity and flexibility, as well as its attractiveness, is in our opinion a useful tool in physics education at university level. (paper)

  4. Does a paresthesia during spinal needle insertion indicate intrathecal needle placement?

    Science.gov (United States)

    Pong, Ryan P; Gmelch, Benjamin S; Bernards, Christopher M

    2009-01-01

    Paresthesias are relatively common during spinal needle insertion, however, the clinical significance of the paresthesia is unknown. A paresthesia may result from needle-to-nerve contact with a spinal nerve in the epidural space, or, with far lateral needle placement, may result from contact with a spinal nerve within the intervertebral foramen. However, it is also possible and perhaps more likely, that paresthesias occur when the spinal needle contacts a spinal nerve root within the subarachnoid space. This study was designed to test this latter hypothesis. Patients (n = 104) scheduled for surgery under spinal anesthesia were observed during spinal needle insertion. If a paresthesia occurred, the needle was fixed in place and the stylet removed to observe whether cerebrospinal fluid (CSF) flowed from the hub. The presence of CSF was considered proof that the needle had entered the subarachnoid space. Paresthesias occurred in 14/103 (13.6%) of patients; 1 patient experienced a paresthesia twice. All paresthesias were transient. Following a paresthesia, CSF was observed in the needle hub 86.7% (13/15) of the time. Our data suggest that the majority of transient paresthesias occur when the spinal needle enters the subarachnoid space and contacts a spinal nerve root. Therefore, when transient paresthesias occur during spinal needle placement it is appropriate to stop and assess for the presence of CSF in the needle hub, rather than withdraw and redirect the spinal needle away from the side of the paresthesia as some authors have suggested.

  5. Exploring the association between macroeconomic indicators and dialysis mortality.

    Science.gov (United States)

    Kramer, Anneke; Stel, Vianda S; Caskey, Fergus J; Stengel, Benedicte; Elliott, Robert F; Covic, Adrian; Geue, Claudia; Cusumano, Ana; Macleod, Alison M; Jager, Kitty J

    2012-10-01

    Mortality on dialysis varies greatly worldwide, with patient-level factors explaining only a small part of this variation. The aim of this study was to examine the association of national-level macroeconomic indicators with the mortality of incident dialysis populations and explore potential explanations through renal service indicators, incidence of dialysis, and characteristics of the dialysis population. Aggregated unadjusted survival probabilities were obtained from 22 renal registries worldwide for patients starting dialysis in 2003-2005. General population age and health, macroeconomic indices, and renal service organization data were collected from secondary sources and questionnaires. Linear modeling with log-log transformation of the outcome variable was applied to establish factors associated with survival on dialysis. Two-year survival on dialysis ranged from 62.3% in Iceland to 89.8% in Romania. A higher gross domestic product per capita (hazard ratio=1.02 per 1000 US dollar increase), a higher percentage of gross domestic product spent on healthcare (1.10 per percent increase), and a higher intrinsic mortality of the dialysis population (i.e., general population-derived mortality risk of the dialysis population in that country standardized for age and sex; hazard ratio=1.04 per death per 10,000 person years) were associated with a higher mortality of the dialysis population. The incidence of dialysis and renal service indicators were not associated with mortality on dialysis. Macroeconomic factors and the intrinsic mortality of the dialysis population are associated with international differences in the mortality on dialysis. Renal service organizational factors and incidence of dialysis seem less important.

  6. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    Science.gov (United States)

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  7. The Green Dialysis Survey: Establishing a Baseline for Environmental Sustainability across Dialysis Facilities in Victoria, Australia.

    Science.gov (United States)

    Barraclough, Katherine A; Gleeson, Alice; Holt, Stephen G; Agar, John Wm

    2017-11-02

    The Green Dialysis Survey aimed to 1) establish a baseline for environmental sustainability (ES) across Victorian dialysis facilities, and 2) guide future initiatives to reduce the environmental impact of dialysis delivery. Nurse unit managers of all Victorian public dialysis facilities received an online link to the survey, which asked 107 questions relevant to the ES of dialysis services. Responses were received from 71/83 dialysis facilities in Victoria (86%), representing 628/660 dialysis chairs (95%). Low energy lighting was present in 13 facilities (18%), 18 (25%) recycled reverse osmosis water and 7 (10%) reported use of renewable energy. Fifty-six facilities (79%) performed comingled recycling but only 27 (38%) recycled polyvinyl chloride plastic. A minority educated staff in appropriate waste management (n=30;42%) or formally audited waste generation and segregation (n=19;27%). Forty-four (62%) provided secure bicycle parking but only 33 (46%) provided shower and changing facilities. There was limited use of tele- or video-conferencing to replace staff meetings (n=19;27%) or patient clinic visits (n=13;18%). A minority considered ES in procurement decisions (n=28;39%) and there was minimal preparedness to cope with climate change. Only 39 services (49%) confirmed an ES policy and few had ever formed a green group (n=14; 20%) or were currently undertaking a green project (n=8;11%). Only 15 facilities (21%) made formal efforts to raise awareness of ES. This survey provides a baseline for practices that potentially impact the environmental sustainability of dialysis units in Victoria, Australia. It also identifies achievable targets for attention. This article is protected by copyright. All rights reserved.

  8. Biodegradable Polymers

    OpenAIRE

    Vroman, Isabelle; Tighzert, Lan

    2009-01-01

    Biodegradable materials are used in packaging, agriculture, medicine and other areas. In recent years there has been an increase in interest in biodegradable polymers. Two classes of biodegradable polymers can be distinguished: synthetic or natural polymers. There are polymers produced from feedstocks derived either from petroleum resources (non renewable resources) or from biological resources (renewable resources). In general natural polymers offer fewer advantages than synthetic polymers. ...

  9. The diagnosis of tuberculosis in dialysis patients

    Directory of Open Access Journals (Sweden)

    Hela Jebali

    2017-01-01

    Full Text Available The incidence of tuberculosis (TB is high in patients undergoing chronic dialysis than it is in the general population. The diagnosis of TB is often difficult and extrapulmonary involvement is predominant. This study investigates the spectrum of clinical presentations and outcome in dialysis patients during a nine-year period. TB was diagnosed in 41 patients. Anti-TB drugs, adverse effects of therapy, and outcome were noted. Thirty-eight patients (92.6% were on hemodialysis and three were on peritoneal dialysis (7.3%. The mean age at diagnosis was 50.8 years and the male/female ratio was 1.16. Four patients had a history of pulmonary TB. Extrapulmonary involvement was observed in 32 (78 % patients. The bacteriological confirmation was made in 41.46% and histological confirmation was made in 26.83%, and in the rest, the diagnosis was retained on the criterion presumption. Nineteen patients (46.34% developed adverse effects of antitubercular drugs. Eight patients (19.51% died during the study from TB or adverse effects of treatment. Low urea reduction ratio and female sex were associated with poor prognosis in our study. The clinical manifestations of TB in patients on dialysis are quite nonspecific, making timely diagnosis difficult, and delaying the initiation of curative treatment, which is a major determinant of the outcome.

  10. The Manchester contribution to peritoneal dialysis

    NARCIS (Netherlands)

    Krediet, Raymond T.

    2011-01-01

    Two names emerge when considering the contribution of Manchester in the development of peritoneal dialysis (PD). The first is Ram Gokal; the second is icodextrin. As there will be a separate article on icodextrin, this one will focus more on other aspects of the activities performed by the Renal

  11. Fungal peritonitis in children on peritoneal dialysis.

    NARCIS (Netherlands)

    Raaijmakers, R.; Schroder, C.; Monnens, L.A.H.; Cornelissen, E.A.M.; Warris, A.

    2007-01-01

    Fungal peritonitis is a rare but serious complication in children on peritoneal dialysis (PD). In this study, risk factors were evaluated, and therapeutic measures were reviewed. A retrospective, multi-centre study was performed in 159 Dutch paediatric PD patients, between 1980 and 2005 (3,573

  12. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    2016-07-27

    Jul 27, 2016 ... The different types of non-surgical breast biopsy procedures include: fine needle aspiration biopsy. (FNAB), core needle ... needle biopsies of breast lesions at a regional public hospital in ..... NCR_2009_FINAL.pdf. 2. Parikh J ...

  13. [Evaluation of methods to calculate dialysis dose in daily hemodialysis].

    Science.gov (United States)

    Maduell, F; Gutiérrez, E; Navarro, V; Torregrosa, E; Martínez, A; Rius, A

    2003-01-01

    Daily dialysis has shown excellent clinical results because a higher frequency of dialysis is more physiological. Different methods have been described to calculate dialysis dose which take into consideration change in frequency. The aim of this study was to calculate all dialysis dose possibilities and evaluate the better and practical options. Eight patients, 6 males and 2 females, on standard 4 to 5 hours thrice weekly on-line hemodiafiltration (S-OL-HDF) were switched to daily on-line hemodiafiltration (D-OL-HDF) 2 to 2.5 hours six times per week. Dialysis parameters were identical during both periods and only frequency and dialysis time of each session were changed. Time average concentration (TAC), time average deviation (TAD), normalized protein catabolic rate (nPCR), Kt/V, equilibrated Kt/V (eKt/V), equivalent renal urea clearance (EKR), standard Kt/V (stdKt/V), urea reduction ratio (URR), hemodialysis product and time off dialysis were measured. Daily on-line hemodiafiltration was well accepted and tolerated. Patients maintained the same TAC although TAD decreased from 9.7 +/- 2 in baseline to a 6.2 +/- 2 mg/dl after six months, p time off dialysis was reduced to half. Dialysis frequency is an important urea kinetic parameter which there are to take in consideration. It's necessary to use EKR, stdKt/V or weekly URR to calculate dialysis dose for an adequate comparison between different frequency dialysis schedules.

  14. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  15. Observations of needle-tissue interactions

    NARCIS (Netherlands)

    Misra, Sarthak; Reed, Kyle B.; Ramesh, K.T.; Okamura, Allison M.

    2009-01-01

    Needles with asymmetric bevel tips naturally bend when they are inserted into soft tissue. In this study, we present an analytical model for the loads developed at the bevel tip during needle-tissue interaction. The model calculates the loads based on the geometry of the bevel edge and gel material

  16. Investigating the Effects of Three Needling Parameters (Manipulation, Retention Time, and Insertion Site) on Needling Sensation and Pain Profiles: A Study of Eight Deep Needling Interventions

    Science.gov (United States)

    Loyeung, Bertrand Y. K.; Cobbin, Deirdre M.

    2013-01-01

    Introduction. In traditional Chinese acupuncture, needle sensation (deqi) is purported to contribute to a therapeutic outcome. While researchers have attempted to define deqi qualitatively, few have examined the effects of needling parameters on its intensity. Methods. 24 healthy subjects completed eight interventions scheduled at least one week apart, which involved manual acupuncture to LI4 or a designated nonacupoint (NAP) on the hand, with real or simulated manipulation each three minutes and needle retentions of one or 21 minutes. Intensities of needling sensation and pain were reported every three minutes and sensation qualities were reported post-intervention. Results. Immediately after needle insertion, similar levels of mean needle sensation and of pain were reported independent of intervention. At subsequent measurement times, only two interventions (one at LI4 and one at NAP) maintained statistically significantly elevated needle sensation and pain scores and reported higher numbers of needle sensation descriptors. For both, the needle was retained for 21 minutes and manipulated every three minutes. Neither intervention differed significantly in terms of levels of pain, and needle sensation or numbers and qualities of needle sensation described. Conclusion. In this group of healthy subjects, the initial needling for all eight interventions elicited similar levels of needle sensation and pain. These levels were only maintained if there was ongoing of needle manipulation and retention of the needle. By contrast, the strength of needle sensation or pain experienced was independent of insertion site. PMID:24159337

  17. [Professor WU Zhongchao's experience of penetration needling].

    Science.gov (United States)

    Zhang, Ning; Wang, Bing; Zhou, Yu

    2016-08-12

    Professor WU Zhongchao has unique application of penetration needling in clinical treatment. Professor WU applies penetration needling along meridians, and the methods of penetration needling include self-meridian penetration, exterior-interior meridian penetration, identical-name meridian penetration, different meridian penetration. The meridian differentiation is performed according to different TCM syndromes, locations and natures of diseases and acupoint nature, so as to make a comprehensive assessment. The qi movement during acupuncture is focused. In addition, attention is paid on anatomy and long-needle penetration; the sequence and direction of acupuncture is essential, and the reinforcing and reducing methods have great originality, presented with holding, waiting, pressing and vibrating. Based on classical acupoint, the acupoint of penetration needling is flexible, forming unique combination of acupoints.

  18. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions  .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Blue Planet dialysis: novel water-sparing strategies for reducing dialysate flow.

    Science.gov (United States)

    Molano-Triviño, Alejandra; Wancjer, Benjamin; Neri, Mauro M; Karopadi, Akash N; Rosner, Mitchell; Ronco, Claudio

    2017-11-08

    Hemodialysis (HD) is an expensive therapy in economic and in ecological terms, owing to a high carbon footprint and significant consumption of natural sources, especially water. Our aim was to review strategies to diminish waste of water in maintenance dialysis, exploring previously described water reuse trends and less known strategies for reducing the dialysate flow. We conducted a systematic review of water-sparing strategies, including the reuse of reverse osmosis rejected water and the reduction of dialysate flux. We performed a search in Medline, Pubmed, Scielo, OVID and Biblioteca Redentor, using key words: Dialysate flow rate, Dialysate flux, and decrease; excluding: online, peritoneal, continuous, blood access, needle, hemodiafiltration, acute, pharmacokinetics, increase. We limited our search to adult humans or in vitro trials in English, Spanish, Italian and Portuguese, between January 1980 and June 2017. We found 816 trials. 37 articles were retrieved for review, and 11 articles were analyzed. Conservation of water in chronic HD should be considered an important responsibility of healthcare practitioners all over the world. We present a wider usage of dialysate flow rates, considering that it would lead to significant water conservation without much compromise on dialysis efficacy in small patients. We believe that further investigation into the utility of reduced dialysate flux in different populations is needed to broaden our understanding of how we can use these techniques in order to significantly reduce water consumption during chronic HD while still ensuring optimum efficacy and efficiency of the therapy.

  20. Polymer compound

    NARCIS (Netherlands)

    1995-01-01

    A Polymer compound comprising a polymer (a) that contains cyclic imidesgroups and a polymer (b) that contains monomer groups with a 2,4-diamino-1,3,5-triazine side group. According to the formula (see formula) whereby themole percentage ratio of the cyclic imides groups in the polymer compoundwith

  1. Biofeedback-driven dialysis: where are we?

    Science.gov (United States)

    Santoro, Antonio; Ferramosca, Emiliana; Mancini, Elena

    2008-01-01

    The progressive increase in the mean age and the growing conditions of co-morbidity, especially of cardiovascular pathologies and diabetes, have significantly worsened the patients' clinical status and tolerance to the hemodialysis (HD) treatment. On the other hand, the demand for short treatment times enhances the risk for hemodynamic instability as well as for inadequate depuration. The traditional management of the dialysis session, setting of predefined treatment parameters, with active therapeutic interventions only in the event of complications, is definitely unsuitable for short-lasting treatments, often complicated by hemodynamic instability, especially in critical patients. The first step to improve the management of the dialysis session is the utilization of continuous and uninvasive monitoring systems for hemodynamic or biochemical parameters involved in the dialysis quality. Special sensors for the continuous measurement of blood volume, blood temperature, blood pressure, heart rate, electrolytes, have been realized throughout the last 10 years. As a second step, some of these devices have been implemented in the dialysis instrumentation, mainly with a view to preventing cardiocirculatory instability but also to control the dialysis efficiency (biofeedback control systems). The basic components of a biofeedback system are: the plant, the sensors, the actuators and the controller. The plant is the biological process that we need to control, while the sensors are the devices used for measuring the output variables. The actuators are the working arms of the controller. The controller is the mathematical model that continuously sets the measured output variable against the reference input and modifies the actuators in order to reduce any discrepancies. Yet, in practice there are a number of conceptual, physical and technological difficulties to be overcome. In particular, the behavior of what is to be controlled may be non-linear and time-varying, with

  2. Polymer electronics

    CERN Document Server

    Hsin-Fei, Meng

    2013-01-01

    Polymer semiconductor is the only semiconductor that can be processed in solution. Electronics made by these flexible materials have many advantages such as large-area solution process, low cost, and high performance. Researchers and companies are increasingly dedicating time and money in polymer electronics. This book focuses on the fundamental materials and device physics of polymer electronics. It describes polymer light-emitting diodes, polymer field-effect transistors, organic vertical transistors, polymer solar cells, and many applications based on polymer electronics. The book also disc

  3. A call to arms: economic barriers to optimal dialysis care.

    Science.gov (United States)

    McFarlane, P A; Mendelssohn, D C

    2000-01-01

    Epidemic growth rates and the enormous cost of dialysis pressure end-stage renal disease (ESRD) delivery systems around the world. Payers of dialysis services can constrain costs through (1) limiting access to dialysis, (2) reducing the quality of dialysis, and (3) placing constraints on modality distribution. In order to secure the necessary resources for ESRD care, we propose that the nephrology community consider the following suggestions: First, future leaders in dialysis should acquire additional advanced training in innovative pathways such as health care economics, business and health care administration, and health care policy. Second, the international nephrology community must strongly engage in ongoing advocacy for accessible, high quality, cost-effective care.Third, efforts should be made to better define and then implement optimal dialysis modality distributions that maximize patient outcomes but limit unnecessary costs. Fourth, industry should be encouraged to lower the unit cost of dialysis, allowing for improved access to dialysis, especially in developing countries. Fifth, research should be encouraged that seeks to identify measures that will reduce dialysis costs but will not impair quality of care. Finally, early referral of patients with progressive renal disease to nephrology clinics, empowerment of informed patient choice of dialysis modality, and proper and timely access creation should be encouraged and can be expected to help limit overall expenditures. Ongoing efforts in these areas by the nephrology community will be essential if we are to overcome the challenges of ESRD growth in this new decade.

  4. Dialysis and Quality of Dialysate in Southeast Asian Developing Countries

    Directory of Open Access Journals (Sweden)

    Tomotaka Naramura

    2014-04-01

    Full Text Available Background: The number of dialysis patients has been increasing in Southeast Asia, but statistical data about these patients and on the quality of dialysates in Southeast Asian dialysis facilities are still imprecise. For this study, dialysis-related statistical data were collected in Southeast Asia. Methods: A survey of the quality of dialysates was carried out at 4 dialysis facilities in Vietnam and Cambodia. The dialysis patient survey included the numbers of dialysis facilities and patients receiving dialysis, a ranking of underlying diseases causing the initiation of dialysis, the number of patients receiving hemodialysis (HD/on-line hemodiafiltration/continuous ambulatory peritoneal dialysis, the number of HD monitoring devices installed, the cost of each session of dialysis (in USD, the percentage of out-of-pocket payments, and the 1-year survival rates of the dialysis patients (in percent. The dialysate survey covered the endotoxin (ET level and bacterial count in tap water, in water filtered through a reverse osmosis system and in dialysate. Results: In each of the countries, the most frequent reason for the initiation of dialysis is diabetes mellitus. HD is usually carried out according to the ‘reuse' principle. The 1-year survival rates are 70% in Myanmar and about 90% in the Philippines and Malaysia. The ET levels in standard dialysates were satisfactory at 2 facilities. The bacterial counts in dialysates were not acceptable at any of the facilities investigated. Conclusion: There is an urgent need to teach medical workers involved in dialysis how to prepare sterile and ET-free dialysates.

  5. Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Topal, U.; Berkman, Yahya M.

    2005-01-01

    Purpose: Occasionally bleeding along the needle trajectory is observed at post-biopsy computed tomographic sections. This study was designed to evaluate the possible effect of needle tract bleeding on the occurrence of pneumothorax and on requirement of chest tube insertion. Materials and methods: Two hundred eighty-four needle biopsies performed in 275 patients in whom the needle traversed the aerated lung parenchyma were retrospectively reviewed. Bleeding along the needle tract, occurrence of pneumothorax and need for chest tube insertion, type and size of the needle, size of the lesion, length of the lung traversed by the needle, presence or absence of emphysema were noted. Effect of these factors on the rate of pneumothorax and needle-tract bleeding was evaluated. The data were analyzed by χ 2 test. Results: Pneumothorax developed in 100 (35%) out of 284 procedures requiring chest tube placement in 16 (16%). Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P 0.05). However, analysis of the relation between length of lung traversed by the needle, tract-bleeding and pneumothorax rate indicated that tract-bleeding had a preventive effect on development of pneumothorax (P 0.05). Conclusion: Bleeding in the needle tract has a preventive effect on the occurrence of the pneumothorax in deep-seated lesions and in the presence of emphysema, although it does not affect the overall rate of pneumothorax

  6. A prime determinant in selecting dialysis modality: peritoneal dialysis patient survival

    Directory of Open Access Journals (Sweden)

    Hyunwook Kim

    2017-03-01

    Full Text Available The number of patients with end-stage renal disease (ESRD has rapidly increased, as has the cost of dialysis. Peritoneal dialysis (PD is an established treatment for ESRD patients worldwide; it has a variety of advantages, including autonomy and flexibility, as well as economic benefits in many countries compared to hemodialysis (HD. However, the long-term survival rate of PD remains poor. Although direct comparison of survival rate between the dialysis modalities by randomized controlled trials is difficult due to the ethical issues, it has always been a crucial point when deciding which dialysis modality should be recommended to patients. Recently, in many countries, including the United States, Brazil, Spain, Australia, and New Zealand, the survival rate in PD patients has significantly improved. PD patient survival in Korea has also improved, but Korean PD patients are known to have higher risk of mortality and major adverse cardiovascular, cerebrovascular events than HD patients. Herein, we further evaluate why Korean PD patients had worse outcomes; we suggest that special attention should be paid to patients with diabetes, coronary artery disease, or congestive heart failure when they choose PD as the first dialysis modality in order to reduce mortality risk.

  7. Capacitive Neutralization Dialysis for Direct Energy Generation.

    Science.gov (United States)

    Liu, Yue; Zhang, Yi; Ou-Yang, Wei; Bastos Sales, Bruno; Sun, Zhuo; Liu, Fei; Zhao, Ran

    2017-08-15

    Capacitive neutralization dialysis energy (CNDE) is proposed as a novel energy-harvesting technique that is able to utilize waste acid and alkaline solutions to produce electrical energy. CNDE is a modification based on neutralization dialysis. It was found that a higher NaCl concentration led to a higher open-circuit potential when the concentrations of acid and alkaline solutions were fixed. Upon closing of the circuit, the membrane potential was used as a driving force to move counter ions into the electrical double layers at the electrode-liquid interface, thereby creating an ionic current. Correspondingly, in the external circuit, electrons flow through an external resistor from one electrode to the other, thereby generating electrical energy directly. The influence of external resistances was studied to achieve greater energy extraction, with the maximum output of 110 mW/m 2 obtained by employing an external resistance of 5 Ω together with the AC-coated electrode.

  8. Sugar export limits size of conifer needles

    DEFF Research Database (Denmark)

    Rademaker, Hanna; Zwieniecki, Maciej A.; Bohr, Tomas

    2017-01-01

    Plant leaf size varies by more than three orders of magnitude, from a few millimeters to over one meter. Conifer leaves, however, are relatively short and the majority of needles are no longer than 6 cm. The reason for the strong confinement of the trait-space is unknown. We show that sugars...... does not contribute to sugar flow. Remarkably, we find that the size of the active part does not scale with needle length. We predict a single maximum needle size of 5 cm, in accord with data from 519 conifer species. This could help rationalize the recent observation that conifers have significantly...

  9. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  10. Dialysis Provision and Implications of Health Economics on Peritoneal Dialysis Utilization: A Review from a Malaysian Perspective.

    Science.gov (United States)

    Abdul Manaf, Mohd Rizal; Surendra, Naren Kumar; Abdul Gafor, Abdul Halim; Seong Hooi, Lai; Bavanandan, Sunita

    2017-01-01

    End-stage renal disease (ESRD) is managed by either lifesaving hemodialysis (HD) and peritoneal dialysis (PD) or a kidney transplant. In Malaysia, the prevalence of dialysis-treated ESRD patients has shown an exponential growth from 504 per million population (pmp) in 2005 to 1155 pmp in 2014. There were 1046 pmp patients on HD and 109 pmp patients on PD in 2014. Kidney transplants are limited due to lack of donors. Malaysia adopts public-private financing model for dialysis. Majority of HD patients were treated in the private sector but almost all PD patients were treated in government facilities. Inequality in access to dialysis is visible within geographical regions where majority of HD centres are scattered around developed areas. The expenditure on dialysis has been escalating in recent years but economic evaluations of dialysis modalities are scarce. Evidence shows that health policies and reimbursement strategies influence dialysis provision. Increased uptake of PD can produce significant economic benefits and improve patients' access to dialysis. As a result, some countries implemented a PD-First or Favored Policy to expand PD use. Thus, a current comparative costs analysis of dialysis is strongly recommended to assist decision-makers to establish a more equitable and economically sustainable dialysis provision in the future.

  11. Dialysis Provision and Implications of Health Economics on Peritoneal Dialysis Utilization: A Review from a Malaysian Perspective

    Directory of Open Access Journals (Sweden)

    Mohd Rizal Abdul Manaf

    2017-01-01

    Full Text Available End-stage renal disease (ESRD is managed by either lifesaving hemodialysis (HD and peritoneal dialysis (PD or a kidney transplant. In Malaysia, the prevalence of dialysis-treated ESRD patients has shown an exponential growth from 504 per million population (pmp in 2005 to 1155 pmp in 2014. There were 1046 pmp patients on HD and 109 pmp patients on PD in 2014. Kidney transplants are limited due to lack of donors. Malaysia adopts public-private financing model for dialysis. Majority of HD patients were treated in the private sector but almost all PD patients were treated in government facilities. Inequality in access to dialysis is visible within geographical regions where majority of HD centres are scattered around developed areas. The expenditure on dialysis has been escalating in recent years but economic evaluations of dialysis modalities are scarce. Evidence shows that health policies and reimbursement strategies influence dialysis provision. Increased uptake of PD can produce significant economic benefits and improve patients’ access to dialysis. As a result, some countries implemented a PD-First or Favored Policy to expand PD use. Thus, a current comparative costs analysis of dialysis is strongly recommended to assist decision-makers to establish a more equitable and economically sustainable dialysis provision in the future.

  12. Single Pass Albumin Dialysis in Hepatorenal Syndrome

    Directory of Open Access Journals (Sweden)

    Rahman Ebadur

    2008-01-01

    Full Text Available Hepatorenal syndrome (HRS is the most appalling complication of acute or chronic liver disease with 90% mortality rate. Single pass albumin dialysis (SPAD can be considered as a noble liver support technique in HRS. Here, we present a case of a young healthy patient who developed hyperacute fulminant liver failure that progressed to HRS. The patient was offered SPAD as a bridge to liver transplantation, however, it resulted in an excellent recovery.

  13. Sacroiliac pain in a dialysis patient

    Science.gov (United States)

    Tristano, Antonio G

    2009-01-01

    The case is reported of a 47-year-old man with a history of chronic renal failure, treated with peritoneal dialysis, who presented with acute sacroiliac joint pain secondary to a pelvic abscess. Initially a diagnosis of infectious sacroiliitis of the left sacroiliac joint was suspected, but following investigation a pain referable to the sacroiliac joint was suspected. The patient recovered with a combination of antibiotics for the pelvic abscess and non-steroidal anti-inflammatory drugs. PMID:21994518

  14. Counter-flow dialysis for microvolume desalting

    OpenAIRE

    Kalikavunkal, Prameen Chacko

    2015-01-01

    Some analytical techniques are not compatible with physiological salt concentrations. An array of desalting approaches exists, but the conventional implementation requires large sample volumes, which is not compatible with fingerprick blood samples for molecular diagnostics. With dialysis being identified as the most suitable method for on-chip microvolume desalting, the aim of this work was to develop a microvolume dialyser that can desalt biological samples to any required salt concentratio...

  15. Waste acid recycling via diffusion dialysis

    Energy Technology Data Exchange (ETDEWEB)

    Steffani, C.

    1995-05-26

    Inorganic acids are commonly used for surface cleaning and finishing of metals. The acids become unuseable due to contamination with metals or diluted and weakened. Diffusion dialysis has become a way to recover the useable acid and allow separation of the metals for recovery and sale to refineries. This technique is made possible by the use of membranes that are strong enough to withstand low ph and have long service life.

  16. Satisfaction with care in peritoneal dialysis patients.

    Science.gov (United States)

    Kirchgessner, J; Perera-Chang, M; Klinkner, G; Soley, I; Marcelli, D; Arkossy, O; Stopper, A; Kimmel, P L

    2006-10-01

    Patient satisfaction is an important aspect of dialysis care, only recently evaluated in clinical studies. We developed a tool to assess peritoneal dialysis (PD) customer satisfaction, and sought to evaluate and validate the Customer Satisfaction Questionnaire (CSQ), quantifying PD patient satisfaction. The CSQ included questions regarding administrative issues, Delivery Service, PD Training, Handling Requests, and transportation. The study was performed using interviews in all Hungarian Fresenius Medical Care dialysis centers offering PD. CSQ results were compared with psychosocial measures to identify if patient satisfaction was associated with perception of social support and illness burden, or depression. We assessed CSQ internal consistency and validity. Factor analysis explored potential underlying dimensions of the CSQ. One hundred and thirty-three patients treated with PD for end-stage renal disease for more than 3 months were interviewed. The CSQ had high internal consistency. There was high patient satisfaction with customer service. PD patient satisfaction scores correlated with quality of life (QOL) and social support measures, but not with medical or demographic factors, or depressive affect. The CSQ is a reliable tool to assess PD customer satisfaction. PD patient satisfaction is associated with perception of QOL. Efforts to improve customer satisfaction may improve PD patients' quantity as well as QOL.

  17. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Zhou Guoyi; Liu Shizhong

    2007-01-01

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  18. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Yuanwen [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: kuangyw@scbg.ac.cn; Wen Dazhi [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: dzwen@scbg.ac.cn; Zhou Guoyi [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: gyzhou@scbg.ac.cn; Liu Shizhong [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: lsz@scbg.ac.cn

    2007-01-15

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants.

  19. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Yuanwen [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: kuangyw@scbg.ac.cn; Wen Dazhi [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: dzwen@scbg.ac.cn; Zhou Guoyi [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: gyzhou@scbg.ac.cn; Liu Shizhong [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: lsz@scbg.ac.cn

    2007-02-15

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants.

  20. [Discussion on needling sensation, arrival of qi and needling response (Deqi)].

    Science.gov (United States)

    Zhang, Fang; Wang, Hong-Du

    2012-12-01

    The current appointed teaching material of Science of Acupuncture and Moxibustion holds that there is no difference among the needling sensation, arrival of qi and needling response. However, the author has a different understanding. Therefore, Neijing (Internal Classic), its annotation, exposition and understandings of ancient and modern famous experts are cited to analyze their meanings. And the result indicates that the needling sensation is subjective feelings and perceived responses of doctors and patients. Arrival of qi is the healing process of the organ through activating the anti-pathogenic qi to expel the pathogens. The needling response is the final aim of acupuncture therapy. Thus, the meaning of needling sensation, arrival of qi, and needling response are different. And an accurate understanding can better guide acupuncture treatment.

  1. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Zhou Guoyi; Liu Shizhong

    2007-01-01

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  2. Peritoneal dialysis in acute renal failure in canines: A review

    Directory of Open Access Journals (Sweden)

    R. H. Bhatt

    Full Text Available Peritoneal dialysis is a technique whereby infusion of dialysis solution into the peritoneal cavity is followed by a variable dwell time and subsequent drainage. During peritoneal dialysis, solutes and fluids are exchanged between the capillary blood and the intraperitoneal fluid through a biologic membrane, the peritoneum. Inadequate renal function leads to disturbance in the removal of the extra fluid and waste products. It removes the waste product and extra fluid from the body in renal failure in small animal practice. Peritoneal dialysis is more accessible, more affordable and easier to administer to the small animal patient. The most common indication for peritoneal dialysis in dogs is acute renal failure (ARF. Peritoneal dialysis is an important therapeutic tool for mitigating clinical signs of uremia and giving the kidneys time to recover in cats with acute kidney injury when conventional therapy is no longer effective. [Vet. World 2011; 4(11.000: 517-521

  3. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  4. Pine needle abortion biomarker detected in bovine fetal fluids

    Science.gov (United States)

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle cons...

  5. Spatial Analysis of Case-Mix and Dialysis Modality Associations.

    Science.gov (United States)

    Phirtskhalaishvili, Tamar; Bayer, Florian; Edet, Stephane; Bongiovanni, Isabelle; Hogan, Julien; Couchoud, Cécile

    2016-01-01

    ♦ Health-care systems must attempt to provide appropriate, high-quality, and economically sustainable care that meets the needs and choices of patients with end-stage renal disease (ESRD). France offers 9 different modalities of dialysis, each characterized by dialysis technique, the extent of professional assistance, and the treatment site. The aim of this study was 1) to describe the various dialysis modalities in France and the patient characteristics associated with each of them, and 2) to analyze their regional patterns to identify possible unexpected associations between case-mixes and dialysis modalities. ♦ The clinical characteristics of the 37,421 adult patients treated by dialysis were described according to their treatment modality. Agglomerative hierarchical cluster analysis was used to aggregate the regions into clusters according to their use of these modalities and the characteristics of their patients. ♦ The gradient of patient characteristics was similar from home hemodialyis (HD) to in-center HD and from non-assisted automated peritoneal dialysis (APD) to assisted continuous ambulatory peritoneal dialysis (CAPD). Analyzing their spatial distribution, we found differences in the patient case-mix on dialysis across regions but also differences in the health-care provided for them. The classification of the regions into 6 different clusters allowed us to detect some unexpected associations between case-mixes and treatment modalities. ♦ The 9 modalities of treatment available make it theoretically possible to adapt treatment to patients' clinical characteristics and abilities. However, although we found an overall appropriate association of dialysis modalities to the case-mix, major inter-region heterogeneity and the low rate of peritoneal dialysis (PD) and home HD suggest that factors besides patients' clinical conditions impact the choice of dialysis modality. The French organization should now be evaluated in terms of patients' quality of

  6. Benfotiamine Protects against Peritoneal and Kidney Damage in Peritoneal Dialysis

    OpenAIRE

    Kihm, Lars P.; Müller-Krebs, Sandra; Klein, Julia; Ehrlich, Gregory; Mertes, Laura; Gross, Marie-Luise; Adaikalakoteswari, Antonysunil; Thornalley, Paul J.; Hammes, Hans-Peter; Nawroth, Peter P.; Zeier, Martin; Schwenger, Vedat

    2011-01-01

    Residual renal function and the integrity of the peritoneal membrane contribute to morbidity and mortality among patients treated with peritoneal dialysis. Glucose and its degradation products likely contribute to the deterioration of the remnant kidney and damage to the peritoneum. Benfotiamine decreases glucose-induced tissue damage, suggesting the potential for benefit in peritoneal dialysis. Here, in a model of peritoneal dialysis in uremic rats, treatment with benfotiamine decreased peri...

  7. Water soluble vitamins and peritoneal dialysis - State of the art.

    Science.gov (United States)

    Jankowska, Magdalena; Lichodziejewska-Niemierko, Monika; Rutkowski, Bolesław; Dębska-Ślizień, Alicja; Małgorzewicz, Sylwia

    2017-12-01

    This review presents the results of a systematic literature search concerning water soluble vitamins and peritoneal dialysis modality. We provide an overview of the data available on vitamin requirements, dietary intake, dialysis related losses, metabolism and the benefits of supplementation. We also summarise the current recommendations concerning the supplementation of vitamins in peritoneal dialysis and discuss the safety of an administration of vitamins in pharmacological doses. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  8. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  9. Fine needle aspiration cytology of cervicofacial actinomycosis

    Directory of Open Access Journals (Sweden)

    Venkatesh Kusuma

    2008-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Cervicofacial actinomycosis presenting as a fixed jaw swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of cervicofacial actinomycosis diagnosed by fine needle aspiration, along with a review of the relevant literature. A 60 year-old man presented with a gradually increasing 6 x 5 cm swelling in the left side of his jaw. The swelling was fixed, without any apparent sinus or abscess. Fine needle aspiration was diagnostic as it revealed colonies of actinomyces surrounded by polymorphs and chronic inflammatory cells. The histopathological study of the excised specimen confirmed the cytological findings. Fine needle aspiration is an effective tool in the diagnosis of actinomycosis although its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the fine needle aspiration technique.

  10. Factors Affecting Hemodialysis Patients' Satisfaction with Their Dialysis Therapy

    Directory of Open Access Journals (Sweden)

    M. Al Eissa

    2010-01-01

    Full Text Available Aim. To assess the degree of satisfaction among hemodialysis patients and the factors influencing this satisfaction. Methods. Patients were recruited from 3 Saudi dialysis centers. Demographic data was collected. Using 1 to 10 Likert scale, the patients were asked to rate the overall satisfaction with, and the overall impact of, their dialysis therapy on their lives and to rate the effect of the dialysis therapy on 15 qualities of life domains. Results. 322 patients were recruited (72.6% of the total eligible patients. The mean age was 51.7 years (±15.4; 58% have been on dialysis for >3 years. The mean Charlson Comorbidity Index was 3.2 (±2, and Kt/V was 1.3 (±0.44. The mean satisfaction score was (7.41 ± 2.75 and the mean score of the impact of the dialysis on the patients' lives was 5.32 ± 2.55. Male patients reported worse effect of dialysis on family life, social life, energy, and appetite. Longer period since the commencement of dialysis was associated with adverse effect on finances and energy. Lower level of education was associated with worse dialysis effect on stress, overall health, sexual life, hobbies, and exercise ability. Conclusion. The level of satisfaction is affected by gender, duration on dialysis, educational level, and standard of care given.

  11. Effects of Physician Payment Reform on Provision of Home Dialysis

    Science.gov (United States)

    Erickson, Kevin F.; Winkelmayer, Wolfgang C.; Chertow, Glenn M.; Bhattacharya, Jay

    2016-01-01

    Objectives Patients with end-stage renal disease can receive dialysis at home or in-center. In 2004 the Centers for Medicare and Medicaid Services reformed physician payment for in-center hemodialysis care from a capitated to a tiered fee-for-service model, augmenting physician payment for frequent in-center visits. We evaluated whether payment reform influenced dialysis modality assignment. Study Design Cohort study of patients starting dialysis in the US in the three years before and after payment reform. Methods We conducted difference-in-difference analyses comparing patients with Traditional Medicare coverage (who were affected by the policy) to others with Medicare Advantage (who were unaffected by the policy). We also examined whether the policy had a more pronounced influence on dialysis modality assignment in areas with lower costs of traveling to dialysis facilities. Results Patients with Traditional Medicare coverage experienced a 0.7% (95% CI 0.2%–1.1%; p=0.003) reduction in the absolute probability of home dialysis use following payment reform compared to patients with Medicare Advantage. Patients living in areas with larger dialysis facilities (where payment reform made in-center hemodialysis comparatively more lucrative for physicians) experienced a 0.9% (95% CI 0.5%–1.4%; ppayment model for dialysis care resulted in fewer patients receiving home dialysis. This area of policy failure highlights the importance of considering unintended consequences of future physician payment reform efforts. PMID:27355909

  12. Peritoneal dialysis-related peritonitis: challenges and solutions

    Science.gov (United States)

    Salzer, William L

    2018-01-01

    Peritoneal dialysis is an effective treatment modality for patients with end-stage renal disease. The relative use of peritoneal dialysis versus hemodialysis varies widely by country. Data from a 2004 survey reports the percentage of patients with end-stage renal disease treated with peritoneal dialysis to be 5%–10% in economically developed regions like the US and Western Europe to as much as 75% in Mexico. This disparity is probably related to the availability and access to hemodialysis, or in some cases patient preference for peritoneal over hemodialysis. Peritoneal dialysis-related peritonitis remains the major complication and primary challenge to the long-term success of peritoneal dialysis. Fifty years ago, with the advent of the Tenckhoff catheter, patients averaged six episodes of peritonitis per year on peritoneal dialysis. In 2016, the International Society for Peritoneal Dialysis proposed a benchmark of 0.5 episodes of peritonitis per year or one episode every 2 years. Despite the marked reduction in peritonitis over time, peritonitis for the individual patient is problematic. The mortality for an episode of peritonitis is 5% and is a cofactor for mortality in another 16% of affected patients. Prevention of peritonitis and prompt and appropriate management of peritonitis is essential for the long-term success of peritoneal dialysis in all patients. In this review, challenges and solutions are addressed regarding the pathogenesis, clinical features, diagnosis, treatment, and prevention of peritoneal dialysis-related peritonitis from the viewpoint of an infectious disease physician.

  13. Periodic Peritoneal Dialysis in End Stage Renal Disease: Is it Still ...

    African Journals Online (AJOL)

    peritoneal dialysis (PD) in India has made renal replacement therapy out of reach of many patients with ... Keywords: Peritoneal dialysis, End stage renal disease, Renal replacement therapy ..... adherence to the dialysis program is often poor.

  14. PHOTOREFRACTIVE POLYMERS

    NARCIS (Netherlands)

    Morichere, D; Malliaras, G.G; Krasnikov, V.V.; Bolink, H.J; Hadziioannou, G

    The use of polymers as photorefractive materials offers many advantages : flexibility in synthesis, doping, processing and low cost. The required functionalities responsible for photorefractivity, namely charge generation, transport, trapping and linear electrooptic effect are given in the polymer

  15. Photorefractive polymers

    NARCIS (Netherlands)

    Bolink, Hendrik Jan; Hadziioannou, G

    1997-01-01

    This thesis describes the synthesis and properties of photorefractive polymers. Photorefractive polymers are materials in which the refractive index can be varied by the interaction with light. Unlike in numerous other photosensitive materials, in photorefractive materials this occurs via

  16. Polymer Brushes

    NARCIS (Netherlands)

    Vos, de W.M.; Kleijn, J.M.; Keizer, de A.; Cosgrove, T.; Cohen Stuart, M.A.

    2010-01-01

    A polymer brush can be defined as a dense array of polymers end-attached to an interface that stretch out into the surrounding medium. Polymer brushes have been investigated for the past 30 years and have shown to be an extremely useful tool to control interfacial properties. This review is intended

  17. Decreasing dialysis catheter rates by creating a multidisciplinary dialysis access program.

    Science.gov (United States)

    Rosenberry, Patricia M; Niederhaus, Silke V; Schweitzer, Eugene J; Leeser, David B

    2018-03-01

    Centers for Medicare and Medicaid Services have determined that chronic dialysis units should have 45%. A multidisciplinary program was established with goals of decreasing catheter rates in order to decrease central line-associated bloodstream infections, decrease mortality associated with central line-associated bloodstream infection, decrease hospital days, and provide savings to the healthcare system. We collected the catheter rates within three dialysis centers served over a 5-year period. Using published data surrounding the incidence and related costs of central line-associated bloodstream infection and mortality per catheter day, the number of central line-associated bloodstream infection events, the costs, and the related mortality could be determined prior to and after the initiation of the dialysis access program. An organized dialysis access program resulted in a 82% decrease in the number of central venous catheter days which lead to a concurrent reduction in central line-associated bloodstream infection and deaths. As a result of creating an access program, central venous catheter rates decreased from an average rate of 45% to 8%. The cost savings related to the program was calculated to be over US$5 million. The decrease in the number of mortalities is estimated to be between 13 and 27 patients. We conclude that a formalized access program decreases catheter rates, central line-associated bloodstream infection, and the resultant hospitalizations, mortality, and costs. Areas with high hemodialysis catheter rates should develop access programs to better serve their patient population.

  18. Comparative Analysis of Serum Levels of Aluminum and Lead in Dialysis Patients, Pre and post Dialysis

    Directory of Open Access Journals (Sweden)

    Atieh Makhlough

    2014-05-01

    Conclusion: Trace elements status in chronic kidney diseases patients is influenced by a renal function residual, size and dialyzer membrane surface. The water nature also is used for dialysis fluid preparation and composition. Trace elements in ESRD patients differed from healthy individuals. So this issue requires accurate studies on trace elements clinical aspects in ESRD patients.

  19. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    Science.gov (United States)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  20. Physical Properties Of Acupuncture Needles: Do Disposable Acupuncture Needles Break With Normal Use

    Science.gov (United States)

    2016-06-01

    Orofacial Pain Graduate...JOURNAL PHYSICAL PROPERTIES OF ACUPUNCTURE NEEDLES: DO DISPOSABLE ACUPUNCTURE NEEDLES BREAK WITH NORMAL USE? James Kyle Vick DDS, Orofacial Pain ...MS CAPT, DC, USN Orofacial Pain Department Head Naval Postgraduate Dental School vi    TABLE OF CONTENTS GUIDELINE I. TITLE

  1. Peritoneal dialysis: a primary care perspective.

    Science.gov (United States)

    Saxena, Ramesh; West, Cheryl

    2006-01-01

    As the population of chronic kidney disease (CKD) and end-stage renal disease (ESRD) grows at an alarming rate, primary care physicians will increasingly be involved in the management of these patients. Early recognition of CKD and timely referral to a nephrologist when glomerular filtration rate approaches 30 mL/min/1.73 m(2) is extremely important to improve ESRD outcome and appropriate selection of dialysis modality. Peritoneal dialysis (PD) remains a viable treatment option for ESRD patients. PD is less expensive dialysis modality and may provide a survival advantages over hemodialysis in first 2 to 4 years of treatment. Preserving residual renal function (RRF) is of paramount importance to prolong the survival outcomes in PD patients. Thus preservation of RRF is an important goal in the management of PD patients. Every effort should be made to avoid nephrotoxic drugs like aminoglycosides and nonsteroidal anti-inflammatory drugs, and limit the use of radiocontrast agents in PD patients with RRF. Judicious use of prophylactic antibiotics to prevent peritonitis would further help to reduce morbidity from PD. Protecting peritoneal membrane from long-term toxic and metabolic effects of the conventional glucose-based solutions is another objective to further improve PD outcome. Development of new, more biocompatible PD solutions holds promise for the future. One such solution, icodextrin, is now approved for use in the United States. Although extremely safe to use, it is associated with unique metabolic effects that may concern primary care physicians. They include false elevation of blood glucose, a reversible increase in serum alkaline phosphatase and a false decline in serum amylase. Monitoring of glycemia by assays that use glucose dehydrogenase pyrroloquinoline quinone enzymes should be avoided and serum amylase alone should not be relied on in diagnosing pancreatitis in patients on icodextrin.

  2. Entropy of uremia and dialysis technology.

    Science.gov (United States)

    Ronco, Claudio

    2013-01-01

    The second law of thermodynamics applies with local exceptions to patient history and therapy interventions. Living things preserve their low level of entropy throughout time because they receive energy from their surroundings in the form of food. They gain their order at the expense of disordering the nutrients they consume. Death is the thermodynamically favored state: it represents a large increase in entropy as molecular structure yields to chaos. The kidney is an organ dissipating large amounts of energy to maintain the level of entropy of the organism as low as possible. Diseases, and in particular uremia, represent conditions of rapid increase in entropy. Therapeutic strategies are oriented towards a reduction in entropy or at least a decrease in the speed of entropy increase. Uremia is a process accelerating the trend towards randomness and disorder (increase in entropy). Dialysis is a factor external to the patient that tends to reduce the level of entropy caused by kidney disease. Since entropy can only increase in closed systems, energy and work must be spent to limit the entropy of uremia. This energy should be adapted to the system (patient) and be specifically oriented and personalized. This includes a multidimensional effort to achieve an adequate dialysis that goes beyond small molecular weight solute clearance. It includes a biological plan for recovery of homeostasis and a strategy towards long-term rehabilitation of the patient. Such objectives can be achieved with a combination of technology and innovation to answer specific questions that are still present after 60 years of dialysis history. This change in the individual bioentropy may represent a local exception to natural trends as the patient could be considered an isolated universe responding to the classic laws of thermodynamics. Copyright © 2013 S. Karger AG, Basel.

  3. [Peritonitis in pediatric patients receiving peritoneal dialysis].

    Science.gov (United States)

    Jellouli, Manel; Ferjani, Meriem; Abidi, Kamel; Hammi, Yosra; Boutiba, Ilhem; Naija, Ouns; Zarrouk, Chokri; Ben Abdallah, Taieb; Gargah, Tahar

    2015-12-01

    Peritonitis on catheter of dialysis represents the most frequent complication of the peritoneal dialysis (PD) in the pediatric population. It remains a significant cause of morbidity and mortality. In this study, we investigated the risk factors for peritonitis in children. In this study, we retrospectively collected the records of 85 patients who were treated with PD within the past ten years in the service of pediatrics of the University Hospital Charles-Nicolle of Tunis. Peritonitis rate was 0.75 episode per patient-year. Notably, peritonitis caused by Gram-positive organisms were more common. Analysis of infection risk revealed three significant independent factors: the poor weight (P=0.0045), the non-automated PD (P=0.02) and the short delay from catheter insertion to starting PD (P=0.02). The early onset peritonitis was significantly associated with frequent peritonitis episodes (P=0.0008). The mean duration between the first and second episode of peritonitis was significantly shorter than between PD commencement and the first episode of peritonitis. We revealed a significant association between Gram-negative peritonitis and the presence of ureterostomy (0.018) and between Gram-positive peritonitis and the presence of exit-site and tunnel infections (0.02). Transition to permanent hemodialysis was needed in many children but no death occurred in patients with peritonitis. Considering the important incidence of peritonitis in our patients, it is imperative to establish a targeted primary prevention. Nutritional care must be provided to children to avoid poor weight. The automated dialysis has to be the modality of choice. Copyright © 2015 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  4. Unusual dialysate leakage complicating peritoneal dialysis

    International Nuclear Information System (INIS)

    Chiu, Jainn-Shiun; Yu, Fu-Chiu; Chen, Chiou-An; Wang, Yuh-Feng

    2006-01-01

    A 16-year-old female who had end-stage renal disease on 2-month continuous ambulatory peritoneal dialysis (CAPD) presented with perineal pain 4 days before admission. The physical examination revealed bilateral labial edema. Peritoneal scintigraphy was requested after infusing 2 L peritoneal dialysate with direct administration of 370 MBq (10mCi) technetium-99m diethylenetriamine pentra-acetic acid into peritoneal cavity via Tenckhoff catheter. Radioactive uptake from right inguinal to labial region was clearly demonstrated, and this indicated the site of peritoneal leakage. After surgical intervention unilaterally, she continued CAPD without any recurrence (au)

  5. Neurological complications of renal dialysis and transplantation.

    Science.gov (United States)

    Karunaratne, Kushan; Taube, David; Khalil, Nofal; Perry, Richard; Malhotra, Paresh A

    2018-04-01

    Neurological complications from renal replacement therapy contribute significantly to morbidity and mortality in patients with renal failure. Such complications can affect either the central or peripheral nervous systems. Most neurological disturbances associated with the uraemic state do not respond fully to renal replacement therapy. There are also complications specifically associated with dialysis and transplantation. A multidisciplinary approach, involving both nephrologists and neurologists, is critical for the diagnosis and effective management of these disorders. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Water-Permeable Dialysis Membranes for Multi-Layered Micro Dialysis System

    Directory of Open Access Journals (Sweden)

    Naoya eTo

    2015-06-01

    Full Text Available This paper presents the development of water-permeable dialysis membranes that are suitable for an implantable microdialysis system that does not use dialysis fluid. We developed a microdialysis system integrating microfluidic channels and nanoporous filtering membranes made of polyethersulfone (PES, aiming at a fully implantable system that drastically improves the quality of life of patients. Simplicity of the total system is crucial for the implantable dialysis system, where the pumps and storage tanks for the dialysis fluid pose problems. Hence, we focus on hemofiltration, which does not require the dialysis fluid but water-permeable membranes. We investigated the water-permeability of the PES membrane with respect to the concentrations of the PES, the additives, and the solvents in the casting solution. Sufficiently water-permeable membranes were found through in vitro experiments using whole bovine blood. The filtrate was verified to have the concentrations of low-molecular-weight molecules, such as sodium, potassium, urea, and creatinine, while proteins, such as albumin, were successfully blocked by the membrane. We conducted in vivo experiments using rats, where the system was connected to the femoral artery and jugular vein. The filtrate was successfully collected without any leakage of blood inside the system and it did not contain albumin but low-molecular-weight molecules whose concentrations were identical to those of the blood. The rat model with renal failure showed 100% increase of creatinine in 5 h, while rats connected to the system showed only a 7.4% increase, which verified the effectiveness of the proposed microdialysis system.

  7. Acute hydrothorax complicating peritoneal dialysis: a case report

    Directory of Open Access Journals (Sweden)

    Ranganathan Dwarkanathan

    2010-11-01

    Full Text Available Abstract Introduction Acute hydrothorax is an uncommon but a well-recognized complication of peritoneal dialysis. No single test is definitive for diagnosis. Although it is not a life-threatening condition, hydrothorax often requires abandonment of peritoneal dialysis. Delay in diagnosis can lead to worsening of the clinical status. Case Presentation A 33-year-old Caucasian woman with lupus, who was successfully treated with temporary peritoneal dialysis 17 years previously, presented with acute dyspnea and a right pleural effusion after recommencing peritoneal dialysis. Investigations eliminated infective, cardiac, and primary respiratory causes. Peritoneal dialysis-related hydrothorax was suggested by biochemistry, and a pleuroperitoneal leak was definitively confirmed by using a Tc-99 m DTPA (diethylene triamine penta-acetic acid scintigraphy scan. Subsequently, she underwent video-assisted thoracoscopy-guided talc pleurodesis and was able to return successfully to peritoneal dialysis. Conclusion Although our case is not the first report that describes the occurrence of acute hydrothorax in peritoneal dialysis, it is an important condition to recognize for the wider general medical community. Furthermore, this case demonstrates that peritoneal dialysis can be continued with a hydrothorax, provided the underlying cause can be corrected. We review the literature pertaining to the utility and reliability of different diagnostic approaches to hydrothorax.

  8. Cardiovascular and noncardiovascular mortality among patients starting dialysis

    DEFF Research Database (Denmark)

    de Jager, Dinanda J; Grootendorst, Diana C; Jager, Kitty J

    2009-01-01

    CONTEXT: Cardiovascular mortality is considered the main cause of death in patients receiving dialysis and is 10 to 20 times higher in such patients than in the general population. OBJECTIVE: To evaluate if high overall mortality in patients starting dialysis is a consequence of increased cardiov...

  9. Haemodialysis at home: review of current dialysis machines.

    Science.gov (United States)

    Haroon, Sabrina; Davenport, Andrew

    2018-04-26

    Only a minority of patients with chronic kidney disease treated by hemodialysis are currently treated at home. Until relatively recently, the only type of hemodialysis machine available for these patients was a slightly smaller version of the standard machines used for in-center dialysis treatments. Areas covered: There are now an alternative generation of dialysis machines specifically designed for home hemodialysis. The home dialysis patient wants a smaller machine, which is intuitive to use, easy to trouble shoot, robust and reliable, quick to setup and put away, requiring minimal waste disposal. The machines designed for home dialysis have some similarities in terms of touch-screen patient interfaces, and using pre-prepared cartridges to speed up setting up the machine. On the other hand, they differ in terms of whether they use slower or standard dialysate flows, prepare batches of dialysis fluid, require separate water purification equipment, or whether this is integrated, or use pre-prepared sterile bags of dialysis fluid. Expert commentary: Dialysis machine complexity is one of the hurdles reducing the number of patients opting for home hemodialysis and the introduction of the newer generation of dialysis machines designed for ease of use will hopefully increase the number of patients opting for home hemodialysis.

  10. Risk factors for peritoneal dialysis catheter failure in children ...

    African Journals Online (AJOL)

    Background Peritoneal dialysis catheter (PDC) failure still remains a common clinical problem in pediatric patients despite advancements in catheter placement and dialysis techniques. Our aim was to determine the risk factors that may lead to PDC failure, especially those factors that could be potentially modified to ...

  11. Predictors of chain acquisition among independent dialysis facilities.

    Science.gov (United States)

    Pozniak, Alyssa S; Hirth, Richard A; Banaszak-Holl, Jane; Wheeler, John R C

    2010-04-01

    To determine the predictors of chain acquisition among independent dialysis providers. Retrospective facility-level data combined from CMS Cost Reports, Medical Evidence Forms, Annual Facility Surveys, and claims for 1996-2003. Independent dialysis facilities' probability of acquisition by a dialysis chain (overall and by chain size) was estimated using a discrete time hazard rate model, controlling for financial and clinical performance, practice patterns, market factors, and other facility characteristics. The sample includes all U.S. freestanding dialysis facilities that report not being chain affiliated for at least 1 year between 1997 and 2003. Above-average costs and better quality outcomes are significant determinants of dialysis chain acquisition. Facilities in larger markets were more likely to be acquired by a chain. Furthermore, small dialysis chains have different acquisition strategies than large chains. Dialysis chains appear to employ a mix of turn-around and cream-skimming strategies. Poor financial health is a predictor of chain acquisition as in other health care sectors, but the increased likelihood of chain acquisition among higher quality facilities is unique to the dialysis industry. Significant differences among predictors of acquisition by small and large chains reinforce the importance of using a richer classification for chain status.

  12. Children's experiences of dialysis: a systematic review of qualitative studies

    NARCIS (Netherlands)

    Tjaden, Lidwien; Tong, Allison; Henning, Paul; Groothoff, Jaap; Craig, Jonathan C.

    2012-01-01

    Objective To describe the experiences and perspectives of children and adolescents on dialysis. Design A systematic review of qualitative studies was conducted that explored the experiences of children on dialysis. Electronic databases and reference lists of relevant articles were searched to

  13. Patients in assisted automated peritoneal dialysis develop strategies for selfcare

    DEFF Research Database (Denmark)

    Holch, Kirsten

      Patients in Assisted Automated Peritoneal Dialysis develop strategies for self-care Background: Since 2000 a model for Assisted Automated Peritoneal Dialysis (AAPD) in the patients own home has been developed at Aarhus University Hospital, Skejby. The patient group consists of physically...

  14. Dialysis and renal transplantation in HIV-infected patients

    DEFF Research Database (Denmark)

    Trullas, Joan Carles; Mocroft, Amanda; Cofan, Federico

    2010-01-01

    To determine prevalence and characteristics of end-stage renal diseases (ESRD) [dialysis and renal transplantation (RT)] among European HIV-infected patients.......To determine prevalence and characteristics of end-stage renal diseases (ESRD) [dialysis and renal transplantation (RT)] among European HIV-infected patients....

  15. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact

  16. Determinants of Adherence to Living on Dialysis for Mexican Americans

    Directory of Open Access Journals (Sweden)

    Shirley A. Wells

    2015-03-01

    Full Text Available This study explores perceptions that affect adherence behaviors among Mexican Americans living with dialysis. In-depth narrative interviews were conducted with 15 Mexican Americans with end-stage renal disease (ESRD living on dialysis, 15 family members, and 6 health care personnel who provided care to them. Four themes emerged: (a positive influences to adherence, (b obstacles to adherence, (c daily activity losses, and (d fears about living with dialysis. From the findings, the perceptions given for non-adherence with the dialysis regimen ranged from denial of the condition, lack of pre-education, to cultural factors. Those given for adherence included prolonged life, family, and hope of getting a transplant. Health care providers were the reminder to adhere. Several cultural factors influenced their adherence perceptions. Strategies to enhance adherence behaviors should focus on knowledge about dialysis, use of the collective efficacy of the family, and the inclusion of cultural values.

  17. Psychosocial adjustment and adherence to dialysis treatment regimes.

    Science.gov (United States)

    Brownbridge, G; Fielding, D M

    1994-12-01

    Sixty children and adolescents in end-stage renal failure who were undergoing either haemodialysis or continuous ambulatory peritoneal dialysis at one of five United Kingdom dialysis centres were assessed on psychosocial adjustment and adherence to their fluid intake, diet and medication regimes. Parental adjustment was also measured and data on sociodemographic and treatment history variables collected. A structured family interview and standardised questionnaire measures of anxiety, depression and behavioural disturbance were used. Multiple measures of treatment adherence were obtained, utilising children's and parents' self-reports, weight gain between dialysis, blood pressure, serum potassium level, blood urea level, dietitians' surveys and consultants' ratings. Correlational analyses showed that low treatment adherence was associated with poor adjustment to diagnosis and dialysis by children and parents (P adherence than younger children, P dialysis (P treatment of this group of children. Future research should develop and evaluate psychosocial interventions aimed at improving treatment adherence.

  18. Medically relevant ElectroNeedle technology development.

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  19. A scalable fabrication process of polymer microneedles

    Directory of Open Access Journals (Sweden)

    Yang S

    2012-03-01

    Full Text Available Sixing Yang, Yan Feng, Lijun Zhang, Nixiang Chen, Weien Yuan, Tuo JinSchool of Pharmacy, Shanghai Jiao Tong University, Shanghai, People's Republic of ChinaAbstract: While polymer microneedles may easily be fabricated by casting a solution in a mold, either centrifugation or vacuumizing is needed to pull the viscous polymer solution into the microholes of the mold. We report a novel process to fabricate polymer microneedles with a one-sided vacuum using a ceramic mold that is breathable but water impermeable. A polymer solution containing polyvinyl alcohol and polysaccharide was cast in a ceramic mold and then pulled into the microholes by a vacuum applied to the opposite side of the mold. After cross-linking and solidification through freeze-thawing, the microneedle patch was detached from the mold and transferred with a specially designed instrument for the drying process, during which the patch shrank evenly to form an array of regular and uniform needles without deformation. Moreover, the shrinkage of the patches helped to reduce the needles' size to ease microfabrication of the male mold. The dried microneedle patches were finally punched to the desired sizes to achieve various properties, including sufficient strength to penetrate skin, microneedles-absorbed water-swelling ratios, and drug-release kinetics. The results showed that the microneedles were strong enough to penetrate pigskin and that their performance was satisfactory in terms of swelling and drug release.Keywords: polymer microneedles, ceramic mold, polyvinyl alcohol, swelling

  20. Home Dialysis in the Prospective Payment System Era.

    Science.gov (United States)

    Lin, Eugene; Cheng, Xingxing S; Chin, Kuo-Kai; Zubair, Talhah; Chertow, Glenn M; Bendavid, Eran; Bhattacharya, Jayanta

    2017-10-01

    The ESRD Prospective Payment System introduced two incentives to increase home dialysis use: bundling injectable medications into a single payment for treatment and paying for home dialysis training. We evaluated the effects of the ESRD Prospective Payment System on home dialysis use by patients starting dialysis in the United States from January 1, 2006 to August 31, 2013. We analyzed data on dialysis modality, insurance type, and comorbidities from the United States Renal Data System. We estimated the effect of the policy on home dialysis use with multivariable logistic regression and compared the effect on Medicare Parts A/B beneficiaries with the effect on patients with other types of insurance. The ESRD Prospective Payment System associated with a 5.0% (95% confidence interval [95% CI], 4.0% to 6.0%) increase in home dialysis use by the end of the study period. Home dialysis use increased by 5.8% (95% CI, 4.3% to 6.9%) among Medicare beneficiaries and 4.1% (95% CI, 2.3% to 5.4%) among patients covered by other forms of health insurance. The difference between these groups was not statistically significant (1.8%; 95% CI, -0.2% to 3.8%). Conversely, in both populations, the training add-on did not associate with increases in home dialysis use beyond the effect of the policy. The ESRD Prospective Payment System bundling, but not the training add-on, associated with substantial increases in home dialysis, which were identical for both Medicare and non-Medicare patients. These spill-over effects suggest that major payment changes in Medicare can affect all patients with ESRD. Copyright © 2017 by the American Society of Nephrology.

  1. Refusal of dialysis amongst patients of chronic kidney disease (CKD)

    International Nuclear Information System (INIS)

    Anees, M.; Khan, J.A.

    2014-01-01

    This study was conducted to determine the refusal of dialysis amongst patients of chronic kidney disease presenting for the first time for dialysis in uremic condition. Study Design: Cross sectional Study. Place and Duration of the Study: Outpatient department of Nephrology, Mayo Hospital, Lahore from 1 st Jan 2012 to 31 st December 2012. Patients and Methods: Patients of CKD due to any cause presenting with uremia for the first time for dialysis were included in the study. History and physical examination was done and demographic data was collected in pre designed form. Patients were offered for dialysis while explaining to them the advantages of getting and disadvantages of not getting dialysis. Patient's response on the offer was recorded and the reason for the refusal were noted. Results: According to the criteria 150 patients were included in the study. Most of the patients were male 92 (61.3%) and illiterate 78 (52.0%). Major cause of CKD was diabetes mellitus 58 (38.7%) followed by hypertension 38 (25.3%). Mean age of the patients was 42.59 ± 13.72 year and income of themost of the patients 126 (84%) was less than US$100/-month. Most of the patients 126 (77.0%) were asked about the need of dialysis in less than three months, 61 (41.3%) offered for the first time and amongst them 85 (54.0%) were offered dialysis already. Majority of the patients 101 (67.3%) refused dialysis when it was offered to them for the first time. Major reason of the refusal was fear of dialysis procedure in 76 (76%) patients followed by treatment by spiritual 14 (14%) and alternative ways and others 11 (11 %). Middle age persons refused dialysis significantly. (author)

  2. Effect of Blinding With a New Pragmatic Placebo Needle

    Science.gov (United States)

    Liu, Baoyan; Xu, Huanfang; Ma, Rui; Mo, Qian; Yan, Shiyan; Liu, Zhishun

    2014-01-01

    Abstract Placebo control is a useful method for determining the efficacy of a therapy. In acupuncture researches, the preferred method for placebo control is acupuncture using a placebo needle that has a blunt tip and achieves no skin penetration. We performed a crossover study to validate the blinding effect of a new type of placebo needle. Sixty volunteers were randomized to receive acupuncture using 2 types of needles with different sequences: sequence AB, involving first the pragmatic placebo needle and then the real needle, and sequence BA, in a reverse order. Placebo acupuncture was performed by administering the placebo needle through an adhesive pad without skin penetration on the acupoints LI4, RN12, BL25, and BL36. Real acupuncture was performed by needling through the pad and penetrating the skin to 15 mm using a real needle on the same acupoints. The acupuncture was administered every other day with 3 sessions for 1 type of needle. The primary outcome was the perception of needle penetration. Besides degree of acupuncture pain, type, and degree of needle sensation, needle acceptability and factors influencing the subject blinding effect were assessed. Needle penetration was felt by 100%, 90% (54/60), 88.3% (53/60), and 95% (57/60) of volunteers receiving placebo acupuncture and 98.3% (59/60), 96.7% (58/60), 95% (57/60), and 95% (57/60) of volunteers receiving real acupuncture on LI4, RN12, BL25, and BL36, respectively. Differences of the volunteers’ perception of needle penetration between the placebo needle and real needle were not significant for the 4 acupoints (all P > 0.05). Volunteers experienced fewer distension sensations (P = 0.01), a lower degree of needle sensation (P = 0.007), and less pain (P = 0.006) during placebo acupuncture than during real acupuncture. The placebo needle was more easily accepted than the real needle (OR = 1.63, 95% CI, 1.01–2.64). The influences of age, sex, educational level, acupuncture

  3. Dialysis Malnutrition and Malnutrition Inflammation Scores: screening tools for prediction of dialysis-related protein-energy wasting in Malaysia.

    Science.gov (United States)

    Harvinder, Gilcharan Singh; Swee, Winnie Chee Siew; Karupaiah, Tilakavati; Sahathevan, Sharmela; Chinna, Karuthan; Ahmad, Ghazali; Bavanandan, Sunita; Goh, Bak Leong

    2016-01-01

    Malnutrition is highly prevalent in Malaysian dialysis patients and there is a need for a valid screening tool for early identification and management. This cross-sectional study aims to examine the sensitivity of the Dialysis Malnutrition Score (DMS) and Malnutrition Inflammation Score (MIS) tools in predicting protein-energy wasting (PEW) among Malaysian dialysis patients. A total of 155 haemodialysis (HD) and 90 peritoneal dialysis (PD) patients were screened for risk of malnutrition using DMS and MIS and comparisons were made with established guidelines by International Society of Renal Nutrition and Metabolism (ISRNM) for PEW. MIS cut-off score of >=5 indicated presence of malnutrition in all patients. A total of 59% of HD and 83% of PD patients had PEW by ISRNM criteria. Based on DMS, 73% of HD and 71% of PD patients exhibited moderate malnutrition, whilst using MIS, 88% and 90%, respectively were malnourished. DMS and MIS correlated significantly in HD (r2=0.552, pmalnutrition classification were established (score >=5) for use amongst Malaysian dialysis patients. Both DMS and MIS are valid tools to be used for nutrition screening of dialysis patients especially those undergoing peritoneal dialysis. The DMS may be a more practical and simpler tool to be utilized in the Malaysian dialysis settings as it does not require laboratory markers.

  4. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  5. Association of education level with dialysis outcome.

    Science.gov (United States)

    Khattak, Muhammad; Sandhu, Gurprataap S; Desilva, Ranil; Goldfarb-Rumyantzev, Alexander S

    2012-01-01

    The impact of education on health care outcome has been studied in the past, but its role in the dialysis population is unclear. In this report, we evaluated this association. We used the United States Renal Data System data of end-stage renal disease patients aged 18 years. Education level at the time of end-stage renal disease onset was the primary variable of interest. The outcome of the study was patient mortality. We used four categories of education level: 0 = less than 12 years of education; 1 = high school graduate; 2 = some college; 3 = college graduate. Subgroups based on age, race, sex, donor type, and diabetic status were also analyzed. After adjustments for covariates in the Cox model, using individuals with less than 12 years of education as a reference, patients with college education showed decreased mortality with hazard ratio of 0.81 (95% confidence interval 0.69–0.95), P = 0.010. In conclusion, we showed that higher education level is associated with improved survival of patients on dialysis.

  6. Modeling and control of dialysis systems

    CERN Document Server

    2013-01-01

    This book is the first text of its kind that presents both the traditional and the modern aspects of dialysis modeling and control in a clear, insightful and highly comprehensive writing style. It provides an in-depth analysis of the mathematical models and algorithms, and demonstrates their applications in real world problems of significant complexity. It explains concepts in a clear, matter-of-fact style. The material of this book will be useful to advanced undergraduate and graduate biomedical engineering students. Also, researchers and practitioners in the field of dialysis, control systems, soft computing will benefit from it. In order to make the reader aware of the applied side of the subject, the book includes:       Chapter openers with a chapter outline, chapter objectives, key terms list, and abstract.       Solved numerical examples to illustrate the application of a particular concept, and also to encourage good problem-solving skills.       More than 1000 questions to give the rea...

  7. Indications for vancomycin in dialysis patients.

    Science.gov (United States)

    Golper, T A; Schulman, G; D'Agata, E M

    2000-01-01

    Resistance to vancomycin has emerged among Staphylococcus aureus, coagulase-negative staphylococci (CNS), and enterococci, and this emergence has particular prevalence in dialysis units. It has therefore become imperative that physicians use vancomycin judiciously. General recommendations regarding the appropriate use of vancomycin have been developed. Although in theory implementation of these guidelines should not be difficult, the medical community may be unable or unwilling to make the necessary adjustments in practice. The onslaught of cost constraints and bureaucratic encumbrance has occurred simultaneously with the increase in vancomycin resistance among pathogens commonly isolated among the dialysis population. When a patient responds to empiric antibiotic therapy and susceptibility data indicate that an antibiotic other than vancomycin would be appropriate, the clinician far too often does not make the change to this alternative. Previously there was no biological imperative to change the antibiotic. That complacency has infected an entire generation of physicians, and especially nephrologists. Furthermore, there is an active movement against change, driven by concerns such as malpractice accusations and frank errors in the interpretation of medical facts.

  8. Peritoneal Dialysis Tailored to Pediatric Needs

    Directory of Open Access Journals (Sweden)

    C. P. Schmitt

    2011-01-01

    Full Text Available Consideration of specific pediatric aspects is essential to achieve adequate peritoneal dialysis (PD treatment in children. These are first of all the rapid growth, in particular during infancy and puberty, which must be accompanied by a positive calcium balance, and the age dependent changes in body composition. The high total body water content and the high ultrafiltration rates required in anuric infants for adequate nutrition predispose to overshooting convective sodium losses and severe hypotension. Tissue fragility and rapid increases in intraabdominal fat mass predispose to hernia and dialysate leaks. Peritoneal equilibration tests should repeatedly been performed to optimize individual dwell time. Intraperitoneal pressure measurements give an objective measure of intraperitoneal filling, which allow for an optimized dwell volume, that is, increased dialysis efficiency without increasing the risk of hernias, leaks, and retrofiltration. We present the concept of adapted PD, that is, the combination of short dwells with low fill volume to promote ultrafiltration and long dwells with a high fill volume to improve purification within one PD session. The use of PD solutions with low glucose degradation product content is recommended in children, but unfortunately still not feasible in many countries.

  9. Biocompatible Peritoneal Dialysis Fluids: Clinical Outcomes

    Directory of Open Access Journals (Sweden)

    Yeoungjee Cho

    2012-01-01

    Full Text Available Peritoneal dialysis (PD is a preferred home dialysis modality and has a number of added advantages including improved initial patient survival and cost effectiveness over haemodialysis. Despite these benefits, uptake of PD remains relatively low, especially in developed countries. Wider implementation of PD is compromised by higher technique failure from infections (e.g., PD peritonitis and ultrafiltration failure. These are inevitable consequences of peritoneal injury, which is thought to result primarily from continuous exposure to PD fluids that are characterised by their “unphysiologic” composition. In order to overcome these barriers, a number of more biocompatible PD fluids, with neutral pH, low glucose degradation product content, and bicarbonate buffer have been manufactured over the past two decades. Several preclinical studies have demonstrated their benefit in terms of improvement in host cell defence, peritoneal membrane integrity, and cytokine profile. This paper aims to review randomised controlled trials assessing the use of biocompatible PD fluids and their effect on clinical outcomes.

  10. Spruce needles used as radioecological biotracers

    International Nuclear Information System (INIS)

    Seidel, C.; Gruber, V.; Baumgartner, A.

    2009-01-01

    In a two years project spruce needle samples of the Austrian Bioindicator Grid were analysed by gamma-ray spectrometry to investigate the spatial and temporal distribution of radionuclides in spruce needles of the last 25 years with the main focus on the radioactive contamination before and after the Chernobyl fallout 1986. More than 600 spruce needle samples at selected locations of the Bioindicator Grid were analysed for different natural and anthropogenic radionuclides: 137 Cs, 40 K, 210 Pb, 226 Ra, 228 Ra, 238 U. Additionally, soil samples were taken at selected sites to study the soil-to-plant transfer. This radioecological evaluation is an important part of an existing environmental surveillance programme in Upper Austria in order to gain basic information on the impact of environmental changes on the radioecological behaviour of spruce trees. (orig.)

  11. Fine needle diagnosis in lumbar osteomyelitis

    International Nuclear Information System (INIS)

    Joshi, K.B.; Brinker, R.A.

    1983-01-01

    Lumbar vertebral body and disk infection, presenting as low back pain, is a relatively uncommon disease but is seen more often in drug addicts. Radiographs show typical changes of infection of the lumbar vertebrae and adjacent disc. Under local anesthesia a fine needle is placed, saline injected, and aspirated. The entire needle-syringe unit is submitted to the bacteriology department. Pseudomonas infection is usually found. This method of diagnosis is simple, cost effective, well accepted by the patients, and can be done on outpatients. (orig.)

  12. [King Injo's disease and burnt needle therapy].

    Science.gov (United States)

    Kim, In-Sook

    2004-12-01

    This paper investigates an interrelationship between burnt needle therapy and King Injo's disease. From 1633 (Year 11 in King Injo's reign) to May 5, 1649 (Year 27 in King Injo's reign), right before his death, King Injo was treated with burnt needles by Yi Hyeongik, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have?Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon ear, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease. The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong derived from her mother, Queen Mother Inmok. Moral justification for King Injo's coup was Gwanghaegun or Prince Gwanghae's immoral conduct toward Queen Mothe Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant rebellions and treasons threatened King Injo. The king suspected that Queen Mother

  13. King Injo's Disease and Burnt Needle Therapy

    Directory of Open Access Journals (Sweden)

    KIM In-Sook

    2004-12-01

    Full Text Available This paper investigates an interrelationship between burnt needle therapy(번침 and King Injo'sdisease. From 1633 (Year 11 in King Injo's reign to May 5, 1649 (Year 27 King in Injo's reign, right before his death, King Injo(인조 was treated with burnt needles by Yi Hyeongik(이형익, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have? Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon era, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease.  The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong(정명공주 derived from her mother, Queen Mother Inmok(인목대비. Moral justification for King Injo's coup was Gwanghaegun(광해군 or Prince Gwanghae's immoral conduct toward Queen Mother Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant

  14. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  15. Analysis of the NovoTwist pen needle in comparison with conventional screw-thread needles.

    Science.gov (United States)

    Aye, Tandy

    2011-11-01

    Administration of insulin via a pen device may be advantageous over a vial and syringe system. Hofman and colleagues introduce a new insulin pen needle, the NovoTwist, to simplify injections to a small group of children and adolescents. Their overall preferences and evaluation of the handling of the needle are reported in the study. This new needle has the potential to ease administration of insulin via a pen device that may increase both the use of a pen device and adherence to insulin therapy. © 2011 Diabetes Technology Society.

  16. Microneedle arrays allow lower microbial penetration than hypodermic needles in vitro.

    Science.gov (United States)

    Donnelly, Ryan F; Singh, Thakur Raghu Raj; Tunney, Michael M; Morrow, Desmond I J; McCarron, Paul A; O'Mahony, Conor; Woolfson, A David

    2009-11-01

    In this study we determined, for the first time, the ability of microorganisms to traverse microneedle-induced holes using two different in vitro models. When employing Silescol membranes, the numbers of Candida albicans, Pseudomonas aeruginosa and Staphylococcus epidermidis crossing the membranes were an order of magnitude lower when the membranes were punctured by microneedles rather than a 21G hypodermic needle. Apart from the movement of C. albicans across hypodermic needle-punctured membranes, where 40.2% of the microbial load on control membranes permeated the barrier over 24 h, the numbers of permeating microorganisms was less than 5% of the original microbial load on control membranes. Experiments employing excised porcine skin and radiolabelled microorganisms showed that the numbers of microorganisms penetrating skin beyond the stratum corneum were approximately an order of magnitude greater than the numbers crossing Silescol membranes in the corresponding experiments. Approximately 10(3) cfu of each microorganism adhered to hypodermic needles during insertion. The numbers of microorganisms adhering to MN arrays were an order of magnitude higher in each case. We have shown here that microneedle puncture resulted in significantly less microbial penetration than did hypodermic needle puncture and that no microorganisms crossed the viable epidermis in microneedle-punctured skin, in contrast to needle-punctured skin. Given the antimicrobial properties of skin, it is, therefore, likely that application of microneedle arrays to skin in an appropriate manner would not cause either local or systemic infection in normal circumstances in immune-competent patients. In supporting widespread clinical use of microneedle-based delivery systems, appropriate animal studies are now needed to conclusively demonstrate this in vivo. Safety in patients will be enhanced by aseptic or sterile manufacture and by fabricating microneedles from self-disabling materials (e

  17. Specific opsonic activity for staphylococci in peritoneal dialysis effluent during continuous ambulatory peritoneal dialysis

    DEFF Research Database (Denmark)

    Nielsen, H; Espersen, F; Kharazmi, A

    1992-01-01

    In a prospective study of intraperitoneal opsonins in 30 patients undergoing continuous ambulatory peritoneal dialysis (CAPD), the IgG concentration, the fibronectin concentration, the specific antistaphylococcal antibody level, and the opsonic activity against Staphylococcus epidermidis were...... measured in peritoneal dialysis effluent from the initiation of CAPD and monthly for 6 months. Significant correlation was found between the four assays, but the interindividual and intraindividual variations were considerable. No statistically significant correlation was observed between susceptibility...... of the patients to CAPD-related infectious peritonitis and any of the above-mentioned parameters of humoral defense. We conclude that at the present time it is not feasible to use these assays for the establishment of prognosis with regard to peritonitis in CAPD....

  18. Aliskiren prevents the toxic effects of peritoneal dialysis fluids during chronic dialysis in rats.

    Directory of Open Access Journals (Sweden)

    Juan Pérez-Martínez

    Full Text Available The benefits of long-term peritoneal dialysis (PD in patients with end-stage renal failure are short-lived due to structural and functional changes in the peritoneal membrane. In this report, we provide evidence for the in vitro and in vivo participation of the renin-angiotensin-aldosterone system (RAAS in the signaling pathway leading to peritoneal fibrosis during PD. Exposure to high-glucose PD fluids (PDFs increases damage and fibrosis markers in both isolated rat peritoneal mesothelial cells and in the peritoneum of rats after chronic dialysis. In both cases, the addition of the RAAS inhibitor aliskiren markedly improved damage and fibrosis markers, and prevented functional modifications in the peritoneal transport, as measured by the peritoneal equilibrium test. These data suggest that inhibition of the RAAS may be a novel way to improve the efficacy of PD by preventing inflammation and fibrosis following peritoneal exposure to high-glucose PDFs.

  19. Polymer Electrolytes

    Science.gov (United States)

    Hallinan, Daniel T.; Balsara, Nitash P.

    2013-07-01

    This review article covers applications in which polymer electrolytes are used: lithium batteries, fuel cells, and water desalination. The ideas of electrochemical potential, salt activity, and ion transport are presented in the context of these applications. Potential is defined, and we show how a cell potential measurement can be used to ascertain salt activity. The transport parameters needed to fully specify a binary electrolyte (salt + solvent) are presented. We define five fundamentally different types of homogeneous electrolytes: type I (classical liquid electrolytes), type II (gel electrolytes), type III (dry polymer electrolytes), type IV (dry single-ion-conducting polymer electrolytes), and type V (solvated single-ion-conducting polymer electrolytes). Typical values of transport parameters are provided for all types of electrolytes. Comparison among the values provides insight into the transport mechanisms occurring in polymer electrolytes. It is desirable to decouple the mechanical properties of polymer electrolyte membranes from the ionic conductivity. One way to accomplish this is through the development of microphase-separated polymers, wherein one of the microphases conducts ions while the other enhances the mechanical rigidity of the heterogeneous polymer electrolyte. We cover all three types of conducting polymer electrolyte phases (types III, IV, and V). We present a simple framework that relates the transport parameters of heterogeneous electrolytes to homogeneous analogs. We conclude by discussing electrochemical stability of electrolytes and the effects of water contamination because of their relevance to applications such as lithium ion batteries.

  20. Star Polymers.

    Science.gov (United States)

    Ren, Jing M; McKenzie, Thomas G; Fu, Qiang; Wong, Edgar H H; Xu, Jiangtao; An, Zesheng; Shanmugam, Sivaprakash; Davis, Thomas P; Boyer, Cyrille; Qiao, Greg G

    2016-06-22

    Recent advances in controlled/living polymerization techniques and highly efficient coupling chemistries have enabled the facile synthesis of complex polymer architectures with controlled dimensions and functionality. As an example, star polymers consist of many linear polymers fused at a central point with a large number of chain end functionalities. Owing to this exclusive structure, star polymers exhibit some remarkable characteristics and properties unattainable by simple linear polymers. Hence, they constitute a unique class of technologically important nanomaterials that have been utilized or are currently under audition for many applications in life sciences and nanotechnologies. This article first provides a comprehensive summary of synthetic strategies towards star polymers, then reviews the latest developments in the synthesis and characterization methods of star macromolecules, and lastly outlines emerging applications and current commercial use of star-shaped polymers. The aim of this work is to promote star polymer research, generate new avenues of scientific investigation, and provide contemporary perspectives on chemical innovation that may expedite the commercialization of new star nanomaterials. We envision in the not-too-distant future star polymers will play an increasingly important role in materials science and nanotechnology in both academic and industrial settings.

  1. Periodontal treatment reduces chronic systemic inflammation in peritoneal dialysis patients.

    Science.gov (United States)

    Siribamrungwong, Monchai; Yothasamutr, Kasemsuk; Puangpanngam, Kutchaporn

    2014-06-01

    Chronic systemic inflammation, a non traditional risk factor of cardiovascular diseases, is associated with increasing mortality in chronic kidney disease, especially peritoneal dialysis patients. Periodontitis is a potential treatable source of systemic inflammation in peritoneal dialysis patients. Clinical periodontal status was evaluated in 32 stable chronic peritoneal dialysis patients by plaque index and periodontal disease index. Hematologic, blood chemical, nutritional, and dialysis-related data as well as highly sensitive C-reactive protein were analyzed before and after periodontal treatment. At baseline, high sensitive C-reactive protein positively correlated with the clinical periodontal status (plaque index; r = 0.57, P periodontal disease index; r = 0.56, P periodontal therapy, clinical periodontal indexes were significantly lower and high sensitivity C-reactive protein significantly decreased from 2.93 to 2.21 mg/L. Moreover, blood urea nitrogen increased from 47.33 to 51.8 mg/dL, reflecting nutritional status improvement. Erythropoietin dosage requirement decreased from 8000 to 6000 units/week while hemoglobin level was stable. Periodontitis is an important source of chronic systemic inflammation in peritoneal dialysis patients. Treatment of periodontal diseases can improve systemic inflammation, nutritional status and erythropoietin responsiveness in peritoneal dialysis patients. © 2013 The Authors. Therapeutic Apheresis and Dialysis © 2013 International Society for Apheresis.

  2. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  3. Effect of ponderosa pine needle litter on grass seedling survival.

    Science.gov (United States)

    Burt R. McConnell; Justin G. Smith

    1971-01-01

    Hard fescue survival rates were followed for 6 years on four different pine needle treatment plots. Needle litter had a significant effect on initial survival of fescue seedlings, but subsequent losses undoubtedly resulted from the interaction of many factors.

  4. Using insulin pen needles up to five times does not affect needle tip shape nor increase pain intensity.

    Science.gov (United States)

    Puder, Jardena J; Atar, Michael; Muller, Beat; Pavan, Marco; Keller, Ulrich

    2005-02-01

    Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.

  5. Tanatophobia in the patients on dialysis

    Directory of Open Access Journals (Sweden)

    Novaković Milan

    2006-01-01

    Full Text Available Background/Aim. Thanatophobia is an exaggerated, specific, structured fear of death. It appears in childhood and continues to grow over the years, and in the old age it is accompanied with nosophobia and other mental disorders. The aim of this study was to analyze thanatophobia in dialysed patients which was in the direct connection with a basic disorder, and the influence of this disorder on functioning and the quality of life of the patients on dialysis. Methods. In the study we examined 753 patients from the chronic program of haemodialysis in a period from 1999 to 2004. The patients were classified in two groups: 348 randomized patients with Balkan Endemic Nephropathy (BEN, and the control group (N18 of patients with terminal renal insufficiency, and other diagnoses (n = 405. Since the study was a comparative, cross-sectional one, the patients were tested by the appropriate questionnaires for anxiety, depression and general mental functioning. Statistical analysis was done by the standard descriptive and analytic statistic methods. Results. Based on socio-demographics data we revealed a highly significant difference regarding the place of living between the groups BEN and N18 (χ2 = 23.970; p < 0.01, the frequency of occurrence of renal comorbidity (χ2 = 23.970; p < 0.01, the frequency of family renal comorbidity in siblings (χ2 = 23.970; p < 0.01, and the frequency of migrationes (χ2 = 4.874; p < 0.01. According to psychiatry scales, the patients from the BEN group were significantly more anxious and depressive than those from the control group. Conclusion. The signs of thanatophobia were revealed in both examined groups, but significantly more in the patients with BEN than in those with other nephrologic diseases. Thanatophobia starts before dialysis, and dialysis structures it into fear of death which is in a direct connection with the basic disorder. This intensive fear may be connected with dementia and depression, but also with

  6. Polymer chemistry (revised edition)

    International Nuclear Information System (INIS)

    Kim, Jae Mum

    1987-02-01

    This book deals with polymer chemistry, which is divided into fourteen chapters. The contents of this book are development of polymer chemistry, conception of polymer, measurement of polymer chemistry, conception of polymer, measurement of polymer, molecule structure of polymer, thermal prosperities of solid polymer, basic theory of polymerization, radical polymerization, ion polymerization, radical polymerization, copolymerization, polymerization by step-reaction, polymer reaction, crown polymer and inorganic polymer on classification and process of creation such as polymeric sulfur and carbon fiber.

  7. Comparative Analysis of Serum Levels of Aluminum and Lead in Dialysis Patients, Pre and post Dialysis

    OpenAIRE

    Atieh Makhlough; Mohammad Shokrzadeh; Maryam Shaliji; Siyavash Abedi

    2014-01-01

    Background: Accumulation or deficiency of trace elements can occur in hemodialysis patients and it increases risk of cardiovascular or other organs disorders. Special ions levels such as sodium and bicarbonate in dialysis fluid are accurately regulated but the remaining elements are not regularly measured. Aluminum and lead belong to the biologic performance free heavy metals .They also has a tendency to accumulate in hemodialysis patients. This study aims to compare serum aluminum and lead l...

  8. Effects of physician payment reform on provision of home dialysis.

    Science.gov (United States)

    Erickson, Kevin F; Winkelmayer, Wolfgang C; Chertow, Glenn M; Bhattacharya, Jay

    2016-06-01

    Patients with end-stage renal disease can receive dialysis at home or in-center. In 2004, CMS reformed physician payment for in-center hemodialysis care from a capitated to a tiered fee-for-service model, augmenting physician payment for frequent in-center visits. We evaluated whether payment reform influenced dialysis modality assignment. Cohort study of patients starting dialysis in the United States in the 3 years before and the 3 years after payment reform. We conducted difference-in-difference analyses comparing patients with traditional Medicare coverage (who were affected by the policy) to others with Medicare Advantage (who were unaffected by the policy). We also examined whether the policy had a more pronounced influence on dialysis modality assignment in areas with lower costs of traveling to dialysis facilities. Patients with traditional Medicare coverage experienced a 0.7% (95% CI, 0.2%-1.1%; P = .003) reduction in the absolute probability of home dialysis use following payment reform compared with patients with Medicare Advantage. Patients living in areas with larger dialysis facilities (where payment reform made in-center hemodialysis comparatively more lucrative for physicians) experienced a 0.9% (95% CI, 0.5%-1.4%; P home dialysis use following payment reform compared with patients living in areas with smaller facilities (where payment reform made in-center hemodialysis comparatively less lucrative for physicians). The transition from a capitated to a tiered fee-for-service payment model for in-center hemodialysis care resulted in fewer patients receiving home dialysis. This area of policy failure highlights the importance of considering unintended consequences of future physician payment reform efforts.

  9. High sensitivity pyrogen testing in water and dialysis solutions.

    Science.gov (United States)

    Daneshian, Mardas; Wendel, Albrecht; Hartung, Thomas; von Aulock, Sonja

    2008-07-20

    The dialysis patient is confronted with hundreds of litres of dialysis solution per week, which pass the natural protective barriers of the body and are brought into contact with the tissue directly in the case of peritoneal dialysis or indirectly in the case of renal dialysis (hemodialysis). The components can be tested for living specimens or dead pyrogenic (fever-inducing) contaminations. The former is usually detected by cultivation and the latter by the endotoxin-specific Limulus Amoebocyte Lysate Assay (LAL). However, the LAL assay does not reflect the response of the human immune system to the wide variety of possible pyrogenic contaminations in dialysis fluids. Furthermore, the test is limited in its sensitivity to detect extremely low concentrations of pyrogens, which in their sum result in chronic pathologies in dialysis patients. The In vitro Pyrogen Test (IPT) employs human whole blood to detect the spectrum of pyrogens to which humans respond by measuring the release of the endogenous fever mediator interleukin-1beta. Spike recovery checks exclude interference. The test has been validated in an international study for pyrogen detection in injectable solutions. In this study we adapted the IPT to the testing of dialysis solutions. Preincubation of 50 ml spiked samples with albumin-coated microspheres enhanced the sensitivity of the assay to detect contaminations down to 0.1 pg/ml LPS or 0.001 EU/ml in water or saline and allowed pyrogen detection in dialysis concentrates or final working solutions. This method offers high sensitivity detection of human-relevant pyrogens in dialysis solutions and components.

  10. Microstructural aspects in steel fiber reinforced acrylic emulsion polymer modified concrete

    Science.gov (United States)

    Hazimmah, Dayang; Ayob, Afizah; Sie Yee, Lau; Chee Cung, Wong

    2018-03-01

    Scanning electron microscope observations of polymer-free and polymer-modified cements have shown that the polymer particles are partitioned between the inside of hydrates and the surface of anhydrous cement grains. For optimum dosage of acrylic emulsion polymer with 2.5%, the C-S-H gel in this structure is finer and more acicular. Some polymer adheres or deposit on the surface of the C-S-H gel. The presence of acrylic emulsion polymer confines the ionic diffusion so that the Ca(OH)2 crystallized locally to form fine crystals. The void in the structures seems to be smaller but no polymer films appears to be bridging the walls of pores although many polymer bonds or C-S-H spread into the pore spaces. In addition to porosity reduction, acrylic emulsion polymer modified the hydration products in the steel fiber -matrix ITZ. The hydration product C-S-H appeared as a needle like shape. The needle-shaped C-S-H increases and gradually formed the gel, with needles growing into the pore space. The phenomenon is more obvious as curing age increased.

  11. Microstructural aspects in steel fiber reinforced acrylic emulsion polymer modified concrete

    Directory of Open Access Journals (Sweden)

    Hazimmah Dayang

    2018-01-01

    Full Text Available Scanning electron microscope observations of polymer-free and polymer-modified cements have shown that the polymer particles are partitioned between the inside of hydrates and the surface of anhydrous cement grains. For optimum dosage of acrylic emulsion polymer with 2.5%, the C-S-H gel in this structure is finer and more acicular. Some polymer adheres or deposit on the surface of the C-S-H gel. The presence of acrylic emulsion polymer confines the ionic diffusion so that the Ca(OH2 crystallized locally to form fine crystals. The void in the structures seems to be smaller but no polymer films appears to be bridging the walls of pores although many polymer bonds or C-S-H spread into the pore spaces. In addition to porosity reduction, acrylic emulsion polymer modified the hydration products in the steel fiber –matrix ITZ. The hydration product C-S-H appeared as a needle like shape. The needle-shaped C-S-H increases and gradually formed the gel, with needles growing into the pore space. The phenomenon is more obvious as curing age increased.

  12. STUDY & ANALYSIS OF MICRO NEEDLE MATERIAL BY ANSYS

    OpenAIRE

    Santosh Kumar Singh*, Prabhat Sinha, N.N. Singh, Nagendra Kumar

    2017-01-01

    In this research the concept of design and analysis, silicon and stainless steel based on hollow micro-needles for transdermal drug delivery(TDD) have been evaluated by Using ANSYS & computational fluid dynamic (CFD), structural. Micro fluidic analysis has performed to ensure the micro-needles design suitability for Drug delivery. The effect of axial and transverse load on single and micro-needle array has investigated with the mechanical properties of micro-needle. The analysis predicte...

  13. Amyloidosis associated with dialysis. Dialyseassoziierte Amyloidosteopathie - radiologische Aspekte

    Energy Technology Data Exchange (ETDEWEB)

    Schadmand, S.; Klose, K.J. (Mainz Univ. (Germany, F.R.). Inst. fuer Klinische Strahlenkunde); Wandel, E. (Mainz Univ. (Germany, F.R.). 1. Medizinische Klinik und Poliklinik)

    1991-06-01

    Amongst the complications of dialysis, amyloid osteopathy is getting increasingly significant. It is due to deposition of {beta}2-microglobulin. To determine the incidence and time of development of this complication, the skeletal radiographs of 185 patients undergoing dialysis, some for up to ten years, were analysed retrospectively. In about 10% of patients, the presence of {beta}2-microglobulin osteopathy may be expected. The radiological features, sites of predilection and differential diagnosis of amyloid osteopathy and of other skeletal changes due to dialysis are discussed. (orig.).

  14. Types of vicarious learning experienced by pre-dialysis patients

    OpenAIRE

    McCarthy, Kate; Sturt, Jackie; Adams, Ann

    2015-01-01

    Objective: Haemodialysis and peritoneal dialysis renal replacement treatment options are in clinical equipoise, although the cost of haemodialysis to the National Health Service is £16,411/patient/year greater than peritoneal dialysis. Treatment decision-making takes place during the pre-dialysis year when estimated glomerular filtration rate drops to between 15 and 30 mL/min/1.73 m2. Renal disease can be familial, and the majority of patients have considerable health service experience when ...

  15. The Single Needle Lockstitch Machine. Module 1.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on parts of the machine, one in a series on the single needle lockstitch sewing machine for student self-study, contains eight sections. Each section contains the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final…

  16. Extrapulmonary tuberculosis: Fine needle aspiration cytology ...

    African Journals Online (AJOL)

    Patients and Methods: This is a consecutive 9-year analysis of patients with peripheral lymphadenopathy. All the patients had fine needle aspiration. Smears were made, fixed in 95% alcohol and stained with hematoxylin and eosin and Zeihl Neelsen stains. Results: 48 patients, 31 males and 17 females, were analyzed.

  17. Acylated flavonol glycosides from Larix needles

    NARCIS (Netherlands)

    Niemann, Gerard J.

    2006-01-01

    Kaempferol-3-p-coumarylglucoside (KCG) was isolated from ether fractions of acetone-extracted freeze-dried needles of all larch species investigated. In each case, KCG was found as one of the main flavonoids, whereas often a variety of closely related, acylated flavonoids was present in either

  18. Relationship between needle phobia and dental anxiety

    NARCIS (Netherlands)

    Majstorovic, M.; Veerkamp, J.S.J.

    2004-01-01

    Purpose: This cross-sectional study aimed to explain the nature of needle phobia and its relationship in dental phobic children with evidence on age-related differences. Methods: The study used 2,865 patients (52% boys, 48% girls), 4 to 11 years old (mean=7.18 years). The patient sample included

  19. Rooting of needle fascicles from western white pine seedlings

    Science.gov (United States)

    Ramond J. Hoff; Geral I. McDonald

    1968-01-01

    In one test, 45 out of 318 (14 percent) needle fascicles from 2-year-old seedlings of Pinus monticola Dougl. were rooted. Eight of the needle fascicles produced shoot growth. In another test, 392 out of 742 (53 percent) needle fascicles were rooted, but none of these produced shoot growth.

  20. 21 CFR 868.5150 - Anesthesia conduction needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient to...

  1. Exploring needle anxiety among students attending a Nigerian ...

    African Journals Online (AJOL)

    Needle anxiety, a form of specific phobia refers to an intense fear of needles used for various medical procedures. It may result in the avoidance of such needle-involving procedures like intramuscular injections or vaccinations. About 4-8% of children and adolescents are said to generally suffer some form of anxiety.

  2. Robotic needle steering: design, modeling, planning, and image guidance

    NARCIS (Netherlands)

    Cowan, Noah J.; Goldberg, Ken; Chirikjian, Gregory S.; Fichtinger, Gabor; Alterovitz, Ron; Reed, Kyle B.; Kallem, Vinutha; Misra, Sarthak; Park, Wooram; Okamura, Allison M.; Rosen, Jacob; Hannaford, Blake; Satava, Richard M.

    2010-01-01

    This chapter describes how advances in needle design, modeling, planning, and image guidance make it possible to steer flexible needles from outside the body to reach specified anatomical targets not accessible using traditional needle insertion methods. Steering can be achieved using a variety of

  3. Measurement of tritium in tissue free water of pine needles

    International Nuclear Information System (INIS)

    Zheng Xiaomin; Wu Zongmei

    1993-01-01

    Tissue Free Water (TFW) of pine needles is separated out through azeotropic distillation of pine needles and toluene. Recovery ratio of TFW is 90%. Tritium activity in the needles is 1.8 Bq/L(H 2 O), which is of the same level with tritiated water vapour (HTO) in atmosphere during the corresponding period

  4. Glucose absorption in acute peritoneal dialysis.

    Science.gov (United States)

    Podel, J; Hodelin-Wetzel, R; Saha, D C; Burns, G

    2000-04-01

    During acute peritoneal dialysis (APD), it is known that glucose found in the dialysate solution contributes to the provision of significant calories. It has been well documented in continuous ambulatory peritoneal dialysis (CAPD) that glucose absorption occurs. In APD, however, it remains unclear how much glucose absorption actually does occur. Therefore, the purpose of this study was to determine whether it is appropriate to use the formula used to calculate glucose absorption in CAPD (Grodstein et al) among patients undergoing APD. Actual measurements of glucose absorption (Method I) were calculated in 9 patients undergoing APD treatment for >24 hours who were admitted to the intensive care unit. Glucose absorption using the Grodstein et al formula (Method II) was also determined and compared with the results of actual measurements. The data was then further analyzed based on the factors that influence glucose absorption, specifically dwell time and concentration. The mean total amount of glucose absorbed was 43% +/- 15%. However, when dwell time and concentration were further examined, significant differences were noted. Method I showed a cumulative increase over time. Method II showed that absorption was fixed. This suggests that with the variation in dwell time commonly seen in the acute care setting, the use of Method II may not be accurate. In each of the 2 methods, a significant difference in glucose absorption was noted when comparing the use of 1.5% and 4.25% dialysate concentrations. The established formula designed for CAPD should not be used for calculating glucose absorption in patients receiving APD because variation in dwell time and concentration should be taken into account. Because of the time constraints and staffing required to calculate each exchange individually, combined with the results of the study, we recommend the use of the percentage estimate of 40% to 50%.

  5. Bladder perforation in a peritoneal dialysis patient

    Directory of Open Access Journals (Sweden)

    M Ounissi

    2012-01-01

    Full Text Available The dysfunction of the catheter in peritoneal dialysis (PD is a frequent compli-cation. However, perforation of organs are rare, particularly that of the urinary bladder. This re-quires an early diagnosis and prompt treatment of patients. We report here the case of a 38-year-old woman having end-stage renal disease due to autosomal-dominant polycystic kidney disease treated by PD since November 2000. Three years later, she was treated for Staphylococcal peritonitis. Four months later, she presented with a severe urge to urinate at the time of the fluid exchanges. The biochemical analysis of the fluid from the bladder showed that it was dialysis fluid. Injection of contrast through the catheter demonstrated the presence of a fistula between the bladder and the peritoneal cavity. She underwent cystoscopic closure of the fistulous tract and the PD catheter was removed. Subsequently, the patient was treated by hemodialysis. One month later, a second catheter was implanted surgically after confirming the closure of the fistula. Ten days later, she presented with pain at the catheter site and along the tunnel, which was found to be swollen along its track. The injection of contrast produced swelling of the subcutaneous tunnel but without extravasation of the dye. PD was withdrawn and the patient was put back on hemodialysis. Bladder fistula is a rare complication in PD and diagnosis should be suspected when patient complains of an urge to pass urine during the exchanges, which can be confirmed by contrast study showing presence of dye in the bladder. PD may be possible after the closure of the fistula, but recurrence may occur.

  6. Hypothyroidism and Mortality among Dialysis Patients

    Science.gov (United States)

    Rhee, Connie M.; Alexander, Erik K.; Bhan, Ishir

    2013-01-01

    Summary Background and objectives Hypothyroidism is highly prevalent among ESRD patients, but its clinical significance and the benefits of thyroid hormone replacement in this context remain unclear. Design, setting, participants, & measurements This study examined the association between hypothyroidism and all-cause mortality among 2715 adult dialysis patients with baseline thyrotropin levels measured between April of 2005 and April of 2011. Mortality was ascertained from Social Security Death Master Index and local registration systems. The association between hypothyroidism (thyrotropin greater than assay upper limit normal) and mortality was estimated using Cox proportional hazards models. To reduce the risk of observing reverse-causal associations, models included a 30-day lag between thyrotropin measurement and at-risk time. Results Among 350 (12.9%) hypothyroid and 2365 (87.1%) euthyroid (assay within referent range) patients, 917 deaths were observed during 5352 patient-years of at-risk time. Hypothyroidism was associated with higher mortality. Compared with thyrotropin in the low-normal range (0.4–2.9 mIU/L), subclinical hypothyroidism (thyrotropin >upper limit normal and ≤10.0 mIU/L) was associated with higher mortality; high-normal thyrotropin (≥3.0 mIU/L and ≤upper limit normal) and overt hypothyroidism (thyrotropin >10.0 mIU/L) were associated with numerically greater risk, but estimates were not statistically significant. Compared with spontaneously euthyroid controls, patients who were euthyroid while on exogenous thyroid replacement were not at higher mortality risk, whereas patients who were hypothyroid were at higher mortality risk. Sensitivity analyses indicated that effects on cardiovascular risk factors may mediate the observed association between hypothyroidism and death. Conclusions These data suggest that hypothyroidism is associated with higher mortality in dialysis patients, which may be ameliorated by thyroid hormone replacement

  7. [Stiletto needle and needle-knife for influence of gravity index in treating knee osteoarthritis].

    Science.gov (United States)

    Gu, Li-Jun; Zhang, Bin; Li, Wen-Hua; Tang, Yan; Dong, Fu-Hui

    2017-12-25

    To explore stiletto needle and needle-knife for influence of double sufficient weight in treating knee osteoarthritis patients. One hundred and thirteen early and medium term knee osteoarthritis patients were randomly divided into three groups, including stiletto needle group(38 cases), needle-knife group (38 cases) and voltaren group (37 cases). In stiletto needle group, there were 13 males and 25 females with an average of(55.87±7.72) years old, treated by stiletto needle once a week, and 2 weeks were a course; there were 11 males and 27 females in needle-knife group with an average of(57.11±7.07) years old, treated by acupotome once a week, and 2 weeks were a course; there were 12 males and 25 females in voltaren group with an average age of(57.62±8.08) years old, treated by votalin emulsion smearing 3 to 5 cm on painful area of knee joint, three times a day for 2 weeks; 36 patients in normal group, including 11 males and 25 females with a mean age of (55.28±7.55) years old, treated with nothing. Gravitational four lattice used to measure bipedal back and forth load before and after treatment in further observe weight-bearing situation among three groups, d value, which was the distance from center of gravity to original point, was measured as a obvervational index, JOA score was used to evaluate clinical effect. Five patients were fall out, including 2 patients in stiletto needle group, 2 patients in needle-knife group and 1 patient in voltaren group. Other 108 patients were followed-up from 28 to 35 d with an average of 30 d, and without untoward effect. There was significant difference in d value between treatment group and control group at 1 month after treatment( P 0.05), and d value was decreased before treatment than that of after treatment. There was no significant difference in JOA score among treatment group after treatment at 1 month( P 0.05) after treatment at 1 month. Stiletto needle, needle-knife and voltaren for the treatment of knee

  8. Reassessment of MxiH subunit orientation and fold within native Shigella T3SS needles using surface labelling and solid-state NMR.

    Science.gov (United States)

    Verasdonck, Joeri; Shen, Da-Kang; Treadgold, Alexander; Arthur, Christopher; Böckmann, Anja; Meier, Beat H; Blocker, Ariel J

    2015-12-01

    T3SSs are essential virulence determinants of many Gram-negative bacteria, used to inject bacterial effectors of virulence into eukaryotic host cells. Their major extracellular portion, a ∼50 nm hollow, needle-like structure, is essential to host cell sensing and the conduit for effector secretion. It is formed of a small, conserved subunit arranged as a helical polymer. The structure of the subunit has been studied by electron cryomicroscopy within native polymers and by solid-state NMR in recombinant polymers, yielding two incompatible atomic models. To resolve this controversy, we re-examined the native polymer used for electron cryomicroscopy via surface labelling and solid-state NMR. Our data show the orientation and overall fold of the subunit within this polymer is as established by solid-state NMR for recombinant polymers. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  10. [Deep needling and shallow needling at three acupoints around ear for subjective tinnitus: a randomized controlled trial].

    Science.gov (United States)

    Yin, Tao; Ni, Jinxia; Zhu, Wenzeng

    2015-10-01

    To compare the effective differences between deep needling and shallow needling at three acupoints around ear for subjective tinnitus. Fifty patients with subjective tinnitus were randomized divided into a deep needling group and a shallow needling group, 25 cases in each group. Twenty-two patients in the deep needling group and 20 patients in the shallow needling group were brought into statistic in the end. In the two groups, the three acupoints around ear and distal acupoints were both selected. The acupoints of the affected side such as Yifeng (TE 17), Tinghui (GB 2), Ermen (TE 21), Zhigou (TE 6), Zhongzhu (TE 3) and Hegu (LI 4) were adopted. Yifeng (TE 17), Tinghui (GB 2) and Ermen (TE 21) were acupunctured 30-38 mm in the deep needling group and 15-20 mm in the shallow needling group. The other acupoints were conventionally acupunctured in the two groups. The needles were retained for 30 min,once a day and five times a week for all patients. The treatment was continuously for 4 weeks in the two groups. Tinnitus handicap inventory (THI) scores, tinnitus grades and visual analogue scale (VAS) for tinnitus sound levels were observed before and after treatment, and the effects of the two groups were compared. The total effective rate in the deep needling group was 59.1% (13/22), and it was better than 20.0% (4/20) in the shallow needling group (P deep needling, group, the THI score, tinnitus grade and the VAS score were improved than those before treatment (all P shallow needling group, the three above indices before and after treatment were not different in statistical significance (all P > 0.05). After treatment, all the three indices in the deep needling group were superior to those in the shallow needling group (all P shallow needling at the three acupoints.

  11. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    International Nuclear Information System (INIS)

    Too, Chow Wei; Sayani, Raza; Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva; Teo, Terence K.

    2016-01-01

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  12. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    Energy Technology Data Exchange (ETDEWEB)

    Too, Chow Wei, E-mail: toochowwei@gmail.com [Singapore General Hospital (Singapore); Sayani, Raza [Aga Khan University Hospital (Pakistan); Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva [Singapore General Hospital (Singapore); Teo, Terence K. [Mount Elizabeth Novena Hospital (Singapore)

    2016-08-15

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  13. Determinants of Peritoneal Dialysis Technique Failure in Incident US Patients

    OpenAIRE

    Shen, Jenny I.; Mitani, Aya A.; Saxena, Anjali B.; Goldstein, Benjamin A.; Winkelmayer, Wolfgang C.

    2013-01-01

    ♦ Objectives: Switching from peritoneal dialysis (PD) to hemodialysis (HD) is undesirable, because of complications from temporary vascular access, disruption of daily routine, and higher costs. Little is known about the role that social factors play in technique failure.

  14. Kidney Dialysis: When Is It Time to Stop?

    Science.gov (United States)

    ... is it time to stop? My 82-year-old husband has been on kidney dialysis for a ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  15. Analysis of Why the Renal Dialysis Unit is Losing Money

    National Research Council Canada - National Science Library

    Moore, Leslie

    1997-01-01

    .... Despite efforts to remain competitive by procuring "state of the art" equipment intended to decrease treatment times and result in cost savings, the renal dialysis product line was losing money...

  16. Diabetic patients treated with dialysis: complications and quality of life

    DEFF Research Database (Denmark)

    Sørensen, V R; Mathiesen, E R; Watt, T

    2007-01-01

    AIMS/HYPOTHESIS: The aim of this study was to describe the prevalence of complications, health-related quality of life (HRQOL) and the influence of beliefs about control over health in diabetic dialysis patients. METHODS: Of 53 eligible diabetic patients on chronic dialysis during January 2004...... in our clinic, 38 (76%) completed a kidney-specific (Kidney Disease Quality of Life) and a generic (SF-36) questionnaire and were characterised in terms of cardiovascular diseases and diabetic complications. Matched groups of non-diabetic dialysis patients (n = 40) and diabetic patients with a long...... population (47 +/- 19). The diabetic dialysis patients had similar levels of kidney-specific quality of life and mental health compared with the control groups. Reduced physical health was predicted by the presence of end-stage renal disease, diabetes and short time spent in education. Among the diabetic...

  17. Pharmacokinetics of amikacin during hemodialysis and peritoneal dialysis

    DEFF Research Database (Denmark)

    Regeur, L; Colding, H; Jensen, H

    1977-01-01

    The pharmacokinetics of amikacin were examined in six bilaterally nephrectomized patients undergoing hemodialysis and in four patients with a minimal residual renal function undergoing peritoneal dialysis. The mean elimination half-life before the dialysis was 86.5 h in the anephric patients and 44...... renal function. During hemodialysis the half-life decreased to less than 10% (5.6 h) of the pretreatment value. The effectiveness of peritoneal dialysis was less as the half-life decreased to only about 30% (17.9 h) of the pretreatment value. During the dialyses a significant correlation between...... the half-life of amikacin and the decrease in blood urea and serum creatinine was demonstrated. The pharmacokinetic data were used to make dosage regimen recommendations for the treatment of patients undergoing intermittent hemodialysis or peritoneal dialysis....

  18. Increasing fill volume reduces cardiac performance in peritoneal dialysis

    DEFF Research Database (Denmark)

    Ivarsen, Per; Povlsen, Johan V; Jensen, Jens Dam

    2007-01-01

    BACKGROUND: It is generally accepted that peritoneal dialysis (PD) affects systemic haemodynamics less than haemodialysis, but little is known about changes in haemodynamics during PD. It is unknown if increasing PD volume causes changes in cardiovascular haemodynamics possibly increasing...

  19. Peritonitis in peritoneal dialysis patients after renal transplantation

    NARCIS (Netherlands)

    Bakir, N; Surachno, S; Sluiter, WJ; Struijk, DG

    1998-01-01

    Background. The occurrence of peritonitis in peritoneal dialysis patients after renal transplantation during immunosuppression might increase morbidity and mortality. Hence the timing of catheter removal is still controversial. The associated risk factors of this complication have not been analyzed.

  20. Peritonitis in peritoneal dialysis patients after renal transplantation

    NARCIS (Netherlands)

    Bakir, N.; Surachno, S.; Sluiter, W. J.; Struijk, D. G.

    1998-01-01

    The occurrence of peritonitis in peritoneal dialysis patients after renal transplantation during immunosuppression might increase morbidity and mortality. Hence the timing of catheter removal is still controversial. The associated risk factors of this complication have not been analyzed. We

  1. Time to Improve Informed Consent for Dialysis: An International Perspective.

    Science.gov (United States)

    Brennan, Frank; Stewart, Cameron; Burgess, Hannah; Davison, Sara N; Moss, Alvin H; Murtagh, Fliss E M; Germain, Michael; Tranter, Shelley; Brown, Mark

    2017-06-07

    The literature reveals that current nephrology practice in obtaining informed consent for dialysis falls short of ethical and legal requirements. Meeting these requirements represents a significant challenge, especially because the benefits and risks of dialysis have shifted significantly with the growing number of older, comorbid patients. The importance of informed consent for dialysis is heightened by several concerns, including: ( 1 ) the proportion of predialysis patients and patients on dialysis who lack capacity in decision making and ( 2 ) whether older, comorbid, and frail patients understand their poor prognosis and the full implications to their independence and functional status of being on dialysis. This article outlines the ethical and legal requirements for a valid informed consent to dialysis: ( 1 ) the patient was competent, ( 2 ) the consent was made voluntarily, and ( 3 ) the patient was given sufficient information in an understandable manner to make the decision. It then considers the application of these requirements to practice across different countries. In the process of informed consent, the law requires a discussion by the physician of the material risks associated with dialysis and alternative options. We argue that, legally and ethically, this discussion should include both the anticipated trajectory of the illness and the effect on the life of the patient with particular regard to the outcomes most important to the individual. In addition, a discussion should occur about the option of a conservative, nondialysis pathway. These requirements ensure that the ethical principle of respect for patient autonomy is honored in the context of dialysis. Nephrologists need to be open to, comfortable with, and skillful in communicating this information. From these clear, open, ethically, and legally valid consent discussions, a significant dividend will hopefully flow for patients, families, and nephrologists alike. Copyright © 2017 by the

  2. Graves′ disease in a dialysis dependent chronic renal failure patient

    Directory of Open Access Journals (Sweden)

    C G Nair

    2014-01-01

    Full Text Available Thyroid hormone level may be altered in chronic renal failure patients. Low levels of thyroxine protect the body from excess protein loss by minimizing catabolism. Hyperthyroidism is rarely encountered in end-stage dialysis dependent patients. Less than 10 well-documented cases of Graves′ disease (GD are reported in literature so far. We report a case of GD in a patient on dialysis.

  3. Daily dialysis reduces pulse wave velocity in chronic hemodialysis patients.

    Science.gov (United States)

    Di Micco, Lucia; Torraca, Serena; Sirico, Maria Luisa; Tartaglia, Domenico; Di Iorio, Biagio

    2012-05-01

    Pulse wave velocity (PWV) is a predictor of morbidity and mortality in patients with end-stage renal disease (ESRD). Dialysis patients show cyclic changes in PWV related to their hydration status and blood pressure. Our aim is to assess the impact of daily dialysis on PWV. We performed a randomized crossover study of 60 patients who underwent standard hemodialysis (HD) three times per week for at least 6 months. Patients were classified into three groups according to their PWV values before (pre-) and after (post-) HD, with a cutoff value of 12 m s(-1), as follows: the low-low (LL) group had normal pre-HD and post-HD PWV; the high-low (HL) group had high pre-HD PWV and normal post-HD PWV; and the high-high (HH) group had high pre- and post-HD PWV. All patients continued standard HD for 2 weeks. A total of 10 patients from each group were randomly assigned to continue standard HD for 1 week and then underwent daily dialysis for 1 week. The remaining 10 patients underwent daily dialysis for 1 week and then underwent standard HD for 1 week. PWV values were measured before and 1 h after each dialysis session. With daily dialysis treatment, 2 of 20 patients (10%) moved from the PWV-HH group to the PWV-HL group, whereas 18 of 20 patients (90%) moved from the PWV-HL group to the PWV-LL group (P = 0.030). Daily dialysis reduces PWV in the ESRD patients. As PWV is a strong predictor of mortality in ESRD and has cyclic variations in patients who are on standard HD, we believe that daily dialysis may be used in patients with high PWV levels to reduce their mortality risk.

  4. Mathematical modeling of fluid and solute transport in peritoneal dialysis

    OpenAIRE

    Waniewski, Jacek

    2001-01-01

    Optimization of peritoneal dialysis schedule and dialysis fluid composition needs, among others, methods for quantitative assessment of fluid and solute transport. Furthermore, an integrative quantitative description of physiological processes within the tissue, which contribute to the net transfer of fluid and solutes, is necessary for interpretation of the data and for predictions of the outcome of possible intervention into the peritoneal transport system. The current pro...

  5. [Customization of hemodialysis therapy: dialysis is not a washing machine].

    Science.gov (United States)

    Santoro, Antonio

    2018-02-01

    In recent years, the population of chronic dialysis has grown in number but also in age and frequency of co-morbidies such as cardiac diseases, vascular pathologies, diabetes, etc. The majority of patients on chronic hemodialysis are over 70 years and, given the high number of comorbidities, they often exhibit poor tolerance to dialysis treatments. A non-tolerated dialytic treatment can have side-effects that would require an intensification of the dialysis sessions and many hospitalizations. Consequently, the problematic dialysis treatments, as well as harmful for the patient, become economically more detrimental than other treatments apparently more expensive but more tolerated ones In the current days we have, thanks to the huge developments in dialysis technology, powerful weapons to ensure effective and scarcely symptomatic dialysis treatments to the majority of the HD patients. New, highly biocompatible membranes with defined and modular cut-off and / or absorption capacity may allow us to provide adequate purification. Moreover the monitoring and biofeedback systems such as blood volume tracking, body temperature monitoring (BTM) and blood pressure (BPM) can be very useful in reducing the risk of intra-dialytic hypotension and symptoms. Therefore, the dialytic therapy, as well as all the pharmacological therapies for the chronic patient, must consider the specificity of the patient, basing on his metabolic problems, cardiovascular tolerance, residual renal function and on his dietary and general compliance. The central aim of the nephrologist is to formulate the better prescription for the individual patient, considering the dialysis modalities, the membrane type, the dry weight (ideal post-dialysis body weight), the frequency and the duration of the weekly sessions and the technological tools that can optimize the treatment. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.

  6. Transperitoneal transport of sodium during hypertonic peritoneal dialysis

    DEFF Research Database (Denmark)

    Graff, J; Fugleberg, S; Brahm, J

    1996-01-01

    The mechanisms of transperitoneal sodium transport during hypertonic peritoneal dialysis were evaluated by kinetic modelling. A total of six nested mathematical models were designed to elucidate the presence or absence of diffusive, non-lymphatic convective and lymphatic convective solute transport....... Experimental results were obtained from 26 non-diabetic patients undergoing peritoneal dialysis. The model validation procedure demonstrated that only diffusive and non-lymphatic convective transport mechanisms were identifiable in the transperitoneal transport of sodium. Non-lymphatic convective sodium...

  7. The research of knitting needle status monitoring setup

    Science.gov (United States)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  8. Natural disasters and dialysis care in the Asia-Pacific.

    Science.gov (United States)

    Gray, Nicholas A; Wolley, Martin; Liew, Adrian; Nakayama, Masaaki

    2015-12-01

    The impact of natural disasters on the provision of dialysis services has received increased attention in the last decade following Hurricane Katrina devastating New Orleans in 2005. The Asia-Pacific is particularly vulnerable to earthquakes, tsunami, typhoons (also known as cyclones and hurricanes) or storms and flooding. These events can seriously interrupt provision of haemodialysis with adverse effects for patients including missed dialysis, increased hospitalization and post-traumatic stress disorder. Furthermore, haemodialysis patients may need to relocate and experience prolonged periods of displacement from family and social supports. In contrast to haemodialysis, most literature suggests peritoneal dialysis in a disaster situation is more easily managed and supported. It has become apparent that dialysis units and patients should be prepared for a disaster event and that appropriate planning will result in reduced confusion and adverse outcomes should a disaster occur. Numerous resources are now available to guide dialysis units, patients and staff in preparation for a possible disaster. This article will examine the disaster experiences of dialysis units in the Asia-Pacific, the impact on patients and staff, methods employed to manage during the disaster and suggested plans for reducing the impact of future disasters. © 2015 Asian Pacific Society of Nephrology.

  9. Pregnancy in chronic dialysis, late diagnosis, and other problems

    Science.gov (United States)

    Ramadani, S.; Nasution, A. T.; Nasution, S.; Lubis, H. R.

    2018-03-01

    The incidence of pregnancy in patients with chronic kidney disease (CKD) undergoing hemodialysis is rare. Forpregnant patients with CKD undergoing regular hemodialysis, the effects of renal disease on the fetus should be noted and require specific strategies. A 30-year-old woman had no menstruation for 4 months. Abdominal ultrasound showed single fetus within 16 weeks of pregnancy. She had previously been in regular hemodialysis twice a week since 2015, then the frequency of hemodialysis was increased to thrice a week for 4 hours/dialysis. During pregnancy, she was given erythropoiesis stimulating agent, controlled protein nutrition (0.6-1.5g/kg/day) and routine pregnancy controls to an obstetrician. After 31-32 weeks gestation, thebaby was born alive with low birth weight (1800g). Maintaining pregnancy in women with regular hemodialysis is still challenging and difficult. Prolonged/intensive dialysis during pregnancy results in longer gestational periods, higher fetal weights, and a higher likelihood of survival. Based on a dialysis guideline for pregnancy in CKD, hemodialysis is performed at least 20 hours/week to maintain pre-dialysis of BUN≤50mg/dl hemoglobin should be at least 10-11g/dL. We reported a case of pregnancy in dialysis CKD patient undergoing hemodialysis thricea week (4 hours/dialysis). The baby was born alive with low birth weight (1800 g).

  10. NUTRIENTS CONCENTRATION AND RETRANSLOCATION IN THE Pinus taeda L. NEEDLES

    Directory of Open Access Journals (Sweden)

    Márcio Viera

    2010-03-01

    Full Text Available Aiming at evaluating nutrients concentration and retranslocation in the Pinus taeda L. needles, this study was developed in two stands, in native grass area and in second rotation area, with same species and same age (7.5 years old in Cambará do Sul, RS. The needles were collected in plants in four orthogonal points (South, North, East and West, sampled new needles, mature needles and old needles. The material was dried in a stove, milled and chemically analyzed (macro and micronutrients. The concentrations of N, P, K, B, Cu and Zn had decreased, of Ca, Fe and Mn increased, and the Mg and S have remained constant with the age of the needles. The retranslocation rate (old-new needles was more than 50% for most nutrients, except for Mn and Fe, showed that cumulative effect and the Ca reference element.

  11. Investigation of environmental pollution with pine needles by NAA

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kil Yong; Yoon, Yoon Yeol; Yang, Myung Kwon; Shim, Sang Kwon; Seo, Bum Kyoung [Korea Inst. of Geosience and Mineral Resources, Environmental Geology Division, Daejeon (Korea); Chung, Yong Sam [Korea Atomic Energy Research Inst., HANARO Center, Daejeon (Japan)

    2002-04-01

    NAA was studied to precision analysis of metallic elements in pine needle. The pine needle was investigated whether it can be feasible or not as a bio-monitor. Only one year old needle was taken from three different regions of urban, suburban and rural area in four seasons. The needle sample was divided with two aliquots, and then one was cleaned and the other was not. Loss and contamination of analytes were cautiously minimized when the needle was sample and transferred from mountain to laboratory and prepared for NAA. Some elements such as As, Br, Ce, W, Zn have shown different characteristics with regions and seasons as well as surface cleaning. It is found that about twenty elements in pine needle could be simply analyzed by NAA and the pine needle could be suitable as a bio-monitor for the monitoring of environmental pollution in Korea. (author)

  12. An Exploration of the Needling Depth in Acupuncture: The Safe Needling Depth and the Needling Depth of Clinical Efficacy

    Directory of Open Access Journals (Sweden)

    Jaung-Geng Lin

    2013-01-01

    Full Text Available Objective. To explore the existing scientific information regarding safe needling depth of acupuncture points and the needling depth of clinical efficacy. Methods. We searched the PubMed, EMBASE, Cochrane, Allied and Complementary Medicine (AMED, The National Center for Complementary and Alternative Medicine (NCCAM, and China National Knowledge Infrastructure (CNKI databases to identify relevant monographs and related references from 1991 to 2013. Chinese journals and theses/dissertations were hand searched. Results. 47 studies were recruited and divided into 6 groups by measuring tools, that is, MRI, in vivo evaluation, CT, ultrasound, dissected specimen of cadavers, and another group with clinical efficacy. Each research was analyzed for study design, definition of safe depth, and factors that would affect the measured depths. Depths of clinical efficacy were discussed from the perspective of de-qi and other clinical observations. Conclusions. Great inconsistency in depth of each point measured from different subject groups and tools exists. The definition of safe depth should be established through standardization. There is also lack of researches to compare the clinical efficacy. A well-designed clinical trial selecting proper measuring tools to decide the actual and advisable needling depth for each point, to avoid adverse effects or complications and promote optimal clinical efficacy, is a top priority.

  13. Needle thoracostomy in the treatment of a tension pneumothorax in trauma patients: what size needle?

    Science.gov (United States)

    Zengerink, Imme; Brink, Peter R; Laupland, Kevin B; Raber, Earl L; Zygun, Dave; Kortbeek, John B

    2008-01-01

    A tension pneumothorax requires immediate decompression using a needle thoracostomy. According to advanced trauma life support guidelines this procedure is performed in the second intercostal space (ICS) in the midclavicular line (MCL), using a 4.5-cm (2-inch) catheter (5-cm needle). Previous studies have shown a failure rate of up to 40% using this technique. Case reports have suggested that this high failure rate could be because of insufficient length of the needle. To analyze the average chest wall thickness (CWT) at the second ICS in the MCL in a trauma population and to evaluate the length of the needle used in needle thoracostomy for emergency decompression of tension pneumothoraces. Retrospective review of major trauma admissions (Injury Severity Score >12) at the Foothills Medical Centre in Calgary, Canada, who underwent a computed tomography chest scan admitted in the period from October 2001 until March 2004. Subgroup analysis on men and women, /=40 years of age was defined a priori. CWT was measured to the nearest 0.01 cm at the second ICS in the MCL. The mean CWT in the 604 male patients and 170 female patients studied averaged 3.50 cm at the left second ICS MCL and 3.51 cm on the right. The mean CWT was significantly higher for women than men (p 4.5 cm and 24.1% to 35.4% of the women studied. A catheter length of 4.5 cm may not penetrate the chest wall of a substantial amount (9.9%-35.4%) of the population, depending on age and gender. This study demonstrates the need for a variable needle length for relief of a tension pneumothorax in certain population groups to improve effectiveness of needle thoracostomy.

  14. [Needling technique of Professor Li Yan-Fang].

    Science.gov (United States)

    Li, Li-Jun

    2014-01-01

    Experiences of needling techniques of Professor LI Ya- fang is introduced in this article. Gentle and superficial insertion is adopted by Professor LI in clinic. Emphases are put on the qi regulation function, needling sensation to the affected region and insertion with both hands, especially the function of the left hand as pressing hand. The gentle and superficial insertion should be done as the follows: hold the needle with the right hand, press gently along the running course of meridians with the left hand to promote qi circulation, hard pressing should be applied at acupoints to disperse the local qi and blood, insert the needle gently and quickly into the subcutaneous region with the right hand, and stop the insertion when patient has the needling sensation. While the fast needling is characterized with shallow insertion and swift manipulation: the left hand of the manipulator should press first along the running course of the meridian, and fix the local skin, hold the needle with the right hand and insert the needle quickly into the acupoint. Withdrawal of the needle should be done immediately after the reinforcing and reducing manipulations. Professor LI is accomplished in qi regulation. It is held by him that regulating qi circulation is essence of acupuncture, letting the patient get the needling sensation is the most important task of needling. Lifting, thrusting and rotation manipulations should be applied to do reinforcing or reducing. The tissue around the tip of the needle should not be too contracted or too relaxed, and the resistance should not be too strong or too weak. The feeling of the insertion hand of the practitioner should not be too smooth or too hesitant. Needle should be inserted into the skin quickly at the moment of hard pressing by the left hand. And then, slow rotation and gentle lifting and thrusting can be applied to promote the needling sensation like electric current pass through and to reach the affected region along the

  15. Congener-specific data of PBDEs in pine needles

    Energy Technology Data Exchange (ETDEWEB)

    Okazawa, Tsuyoshi; Hanari, Nobuyasu [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Guruge, Keerthi; Yamashita, Nobuyoshi [National Institute of Animal Health (NIAH), Tsukuba (Japan); Wzykowska, B.; Orlikowska, A.; Falandysz, J. [Gdansk Univ. (Poland)

    2004-09-15

    Polybrominated diphenyl ethers (PBDEs) are from many years used as one of the most popular group of brominated flame retardants which are added to a variety of goods and especially those based on plastic polymer materials. DecaBDE is the primarily formulation used amongst of PBDEs while less are pentaBDE and octaBDE, which both are banned in Europe since 2004. PBDEs in general properties and environmental fate well resemble chlorinated and brominated naphthalenes/biphenyls (PCNs, PBNs, PCBs, PBBs) and seems to possess a similar threat due to bioaccumulation and toxicity. Recently several investigations have done to make clear environmental residue of PBDEs and some of brominated dibenzo-pdioxins (PBDDs) and furans (PBDFs). However most of these analysis subjected in environmental matrix is sediment and biota those show relatively high concentration residues. There is no reliable report of PBDEs/PBDDs/PBDFs in ambient air because of un-clarified resident time related to the relatively easy degradation by photo catalysis in air. It is urgent issue to develop a reliable indicator of air pollution by these chemicals. In this communication we are presented early data of the analytical method developed enabling simultaneous separation of several PBDE and PBDD/DF congeners as well as good applicability on pine needles as passive indicator of source emission related troposphere pollution with PBDEs in Tokyo Bay area in Japan.

  16. Prevalence of Cognitive Impairment Among Peritoneal Dialysis Patients, Impact on Peritonitis and Role of Assisted Dialysis.

    Science.gov (United States)

    Shea, Yat Fung; Lam, Man Fai; Lee, Mi Suen Connie; Mok, Ming Yee Maggie; Lui, Sing-Leung; Yip, Terence P S; Lo, Wai Kei; Chu, Leung Wing; Chan, Tak-Mao

    2016-01-01

    ♦ Chronic renal failure and aging are suggested as risk factors for cognitive impairment (CI). We studied the prevalence of CI among peritoneal dialysis (PD) patients using Montreal Cognitive Assessment (MoCA), its impact on PD-related peritonitis in the first year, and the potential role of assisted PD. ♦ One hundred fourteen patients were newly started on PD between February 2011 and July 2013. Montreal Cognitive Assessment was performed in the absence of acute illness. Data on patient characteristics including demographics, comorbidities, blood parameters, dialysis adequacy, presence of helpers, medications, and the number PD-related infections were collected. ♦ The age of studied patients was 59±15.0 years, and 47% were female. The prevalence of CI was 28.9%. Patients older than 65 years old (odds ratio [OR] 4.88, confidence interval [CI] 1.79 - 13.28 p = 0.002) and with an education of primary level or below (OR 4.08, CI 1.30 - 12.81, p = 0.016) were independent risk factors for CI in multivariate analysis. Patients with PD-related peritonitis were significantly older (p peritonitis among self-care PD patients (OR 2.20, CI 0.65 - 7.44, p = 0.20). When we compared patients with MoCA-defined CI receiving self-care and assisted PD, there were no statistically significant differences between the 2 groups in terms of age, MoCA scores, or comorbidities. There were also no statistically significant differences in 1-year outcome of PD-related peritonitis rates or exit-site infections. ♦ Cognitive impairment is common among local PD patients. Even with CI, peritonitis rate in self-care PD with adequate training is similar to CI patients on assisted PD. Copyright © 2016 International Society for Peritoneal Dialysis.

  17. A plasma needle generates nitric oxide

    International Nuclear Information System (INIS)

    Stoffels, E; Gonzalvo, Y Aranda; Whitmore, T D; Seymour, D L; Rees, J A

    2006-01-01

    Generation of nitric oxide (NO) by a plasma needle is studied by means of mass spectrometry. The plasma needle is an atmospheric glow generated by a radio-frequency excitation in a mixture of helium and air. This source is used for the treatment of living tissues, and nitric oxide may be one of the most important active agents in plasma therapy. Efficient NO generation is of particular importance in the treatment of cardiovascular diseases. Mass spectrometric measurements have been performed under various plasma conditions; gas composition in the plasma and conversion of feed gases (nitrogen and oxygen) into other species has been studied. Up to 30% of the N 2 and O 2 input is consumed in the discharge, and NO has been identified as the main conversion product

  18. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological...... diagnostic classes were introduced. The aim of this study was to evaluate the quality assurance programme in a screening population to determine whether fine needle aspiration cytology (FNAC) as first choice remains a useful tool in the preoperative diagnostics, or if needle core biopsy should be the first...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  19. Maxillofacial Changes in Melnick-Needles Syndrome

    Directory of Open Access Journals (Sweden)

    Leilane Larissa Albuquerque do Nascimento

    2016-01-01

    Full Text Available Background. Melnick-Needles Syndrome is rare congenital hereditary skeletal dysplasia caused by mutations in the FLNA gene, which codifies the protein filamin A. This condition leads to serious skeletal abnormalities, including the stomatognathic region. Case Presentation. This paper describes the case of a 13-year-old girl diagnosed with Melnick-Needles Syndrome presenting with different forms of skeletal dysplasia, such as cranial hyperostosis, short upper limbs, bowed long bones, metaphyseal thickening, genu valgum (knock-knee, shortened distal phalanges, narrow pelvis and shoulders, rib tapering and irregularities, elongation of the vertebrae, kyphoscoliosis, micrognathia, hypoplastic coronoid processes of the mandible, left stylohyoid ligament suggesting ossification, and dental development anomalies. Conclusion. Knowledge of this rare syndrome on the part of dentists is important due to the fact that this condition involves severe abnormalities of the stomatognathic system that cause an impact on the development of the entire face as well as functional and esthetic impairments.

  20. Peritoneal Fluid Transport rather than Peritoneal Solute Transport Associates with Dialysis Vintage and Age of Peritoneal Dialysis Patients

    Directory of Open Access Journals (Sweden)

    Jacek Waniewski

    2016-01-01

    Full Text Available During peritoneal dialysis (PD, the peritoneal membrane undergoes ageing processes that affect its function. Here we analyzed associations of patient age and dialysis vintage with parameters of peritoneal transport of fluid and solutes, directly measured and estimated based on the pore model, for individual patients. Thirty-three patients (15 females; age 60 (21–87 years; median time on PD 19 (3–100 months underwent sequential peritoneal equilibration test. Dialysis vintage and patient age did not correlate. Estimation of parameters of the two-pore model of peritoneal transport was performed. The estimated fluid transport parameters, including hydraulic permeability (LpS, fraction of ultrasmall pores (αu, osmotic conductance for glucose (OCG, and peritoneal absorption, were generally independent of solute transport parameters (diffusive mass transport parameters. Fluid transport parameters correlated whereas transport parameters for small solutes and proteins did not correlate with dialysis vintage and patient age. Although LpS and OCG were lower for older patients and those with long dialysis vintage, αu was higher. Thus, fluid transport parameters—rather than solute transport parameters—are linked to dialysis vintage and patient age and should therefore be included when monitoring processes linked to ageing of the peritoneal membrane.

  1. Peritoneal Fluid Transport rather than Peritoneal Solute Transport Associates with Dialysis Vintage and Age of Peritoneal Dialysis Patients

    Science.gov (United States)

    Waniewski, Jacek; Antosiewicz, Stefan; Baczynski, Daniel; Poleszczuk, Jan; Pietribiasi, Mauro; Lindholm, Bengt; Wankowicz, Zofia

    2016-01-01

    During peritoneal dialysis (PD), the peritoneal membrane undergoes ageing processes that affect its function. Here we analyzed associations of patient age and dialysis vintage with parameters of peritoneal transport of fluid and solutes, directly measured and estimated based on the pore model, for individual patients. Thirty-three patients (15 females; age 60 (21–87) years; median time on PD 19 (3–100) months) underwent sequential peritoneal equilibration test. Dialysis vintage and patient age did not correlate. Estimation of parameters of the two-pore model of peritoneal transport was performed. The estimated fluid transport parameters, including hydraulic permeability (LpS), fraction of ultrasmall pores (α u), osmotic conductance for glucose (OCG), and peritoneal absorption, were generally independent of solute transport parameters (diffusive mass transport parameters). Fluid transport parameters correlated whereas transport parameters for small solutes and proteins did not correlate with dialysis vintage and patient age. Although LpS and OCG were lower for older patients and those with long dialysis vintage, αu was higher. Thus, fluid transport parameters—rather than solute transport parameters—are linked to dialysis vintage and patient age and should therefore be included when monitoring processes linked to ageing of the peritoneal membrane. PMID:26989432

  2. A retractable barb needle for drug darts

    Directory of Open Access Journals (Sweden)

    G.L. van Rooyen

    1973-07-01

    Full Text Available The mechanism and action of a new retractable barbneedle for drug darts are described. This dart needle is particularly successful in obviating unnecessary flight reactions andtrauma in darted animals, and facilitates the complete injection of the drug dose before the barb is retracted and the dart is dislogded from the animal. The whole process is completed within a few seconds and the expended dart can usually be retrieved in the immediate vicinity where the animal was darted.

  3. Pancreatic cancer seeding of percutaneous needle tract

    Directory of Open Access Journals (Sweden)

    Qiao Zhou, MD

    2017-03-01

    Full Text Available A 65-year old African-American female presents with biliary ductal dilatation due to an obstructive pancreatic head mass. Percutaneous transhepatic cholangiogram performed and biliary drainage catheter placement for decompression of the biliary system. The patient had a Whipple procedure performed several months later. On follow up CT imaging, there was interval development and enlargement of a subcutaneous lesion by the right oblique muscles. Biopsy of this lesion revealed pancreatic adenocarcinoma from percutaneous seeding of the transhepatic needle tract.

  4. Polymer Nanocomposites

    Indian Academy of Sciences (India)

    methods for the synthesis of polymer nanocomposites. In this article we .... ers, raw materials recovery, drug delivery and anticorrosion .... region giving rise to dose-packed absorption bands called an IR ... using quaternary ammonium salts.

  5. Early Dialysis and Adverse Outcomes After Hurricane Sandy.

    Science.gov (United States)

    Lurie, Nicole; Finne, Kristen; Worrall, Chris; Jauregui, Maria; Thaweethai, Tanayott; Margolis, Gregg; Kelman, Jeffrey

    2015-09-01

    Hemodialysis patients have historically experienced diminished access to care and increased adverse outcomes after natural disasters. Although "early dialysis" in advance of a storm is promoted as a best practice, evidence for its effectiveness as a protective measure is lacking. Building on prior work, we examined the relationship between the receipt of dialysis ahead of schedule before the storm (also known as early dialysis) and adverse outcomes of patients with end-stage renal disease in the areas most affected by Hurricane Sandy. Retrospective cohort analysis, using claims data from the Centers for Medicare & Medicaid Services Datalink Project. Patients receiving long-term hemodialysis in New York City and the state of New Jersey, the areas most affected by Hurricane Sandy. Receipt of early dialysis compared to their usual treatment pattern in the week prior to the storm. Emergency department (ED) visits, hospitalizations, and 30-day mortality following the storm. Of 13,836 study patients, 8,256 (60%) received early dialysis. In unadjusted logistic regression models, patients who received early dialysis were found to have lower odds of ED visits (OR, 0.75; 95% CI, 0.63-0.89; P=0.001) and hospitalizations (OR, 0.77; 95% CI, 0.65-0.92; P=0.004) in the week of the storm and similar odds of 30-day mortality (OR, 0.80; 95% CI, 0.58-1.09; P=0.2). In adjusted multivariable logistic regression models, receipt of early dialysis was associated with lower odds of ED visits (OR, 0.80; 95% CI, 0.67-0.96; P=0.01) and hospitalizations (OR, 0.79; 95% CI, 0.66-0.94; P=0.01) in the week of the storm and 30-day mortality (OR, 0.72; 95% CI, 0.52-0.997; P=0.048). Inability to determine which patients were offered early dialysis and declined and whether important unmeasured patient characteristics are associated with receipt of early dialysis. Patients who received early dialysis had significantly lower odds of having an ED visit and hospitalization in the week of the storm and of

  6. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  7. John Dique: dialysis pioneer and political advocate.

    Science.gov (United States)

    George, Charles R P

    2016-02-01

    John Dique (1915-1995) epitomized the internationalism of medicine, the intellectual and manual dexterity of many pioneers of dialysis, and the social concern evinced by many nephrologists. Born in Burma of French, German, British and Indian ancestry; educated in India; an Anglo-Indian who described himself as British without ever having visited Britain; he moved to Australia in 1948 to escape the murderous inter-ethnic conflict that befell multicultural India as it and Pakistan became independent. Settling in Brisbane, he pioneered several novel medical techniques. After inventing some simple equipment to facilitate intravenous therapy, he established a neonatal exchange blood transfusion programme. Then, between 1954 and 1963, he personally constructed and operated two haemodialysis machines with which to treat patients suffering from acute renal failure, the first such treatment performed in Australasia. His patients survival results were, for the era, remarkable. He subsequently helped found the Royal Australasian College of Pathologists and went on to establish a successful private pathology practice. The latter years of his life, however, saw him become a social and political advocate. He fiercely opposed the emerging ideologies of multiculturalism and social liberalism that, he predicted, would seriously damage the national fabric of Western society. Public vilification ensued, his medical achievements disregarded. It does seem likely, however, that in none of the areas that he touched - whether medical, social, or political - has the last word yet been said.

  8. Infantile cystinosis: From dialysis to renal transplantation

    Directory of Open Access Journals (Sweden)

    Manel Jellouli

    2017-01-01

    Full Text Available Cystinosis is an autosomal recessive, lysosomal storage disease characterised by the accumulation of the amino acid cystine in different organs and tissues. It is a multisystemic disease that can present with renal and extra-renal manifestations. In this report, we present the first case of transplanted nephropathic cystinosis in a Tunisian child. A 4-year-old Tunisian boy born to nonconsanguineous parents, was treated in our medical services in 1990 for cystinosis. Since the age of five months, he developed symptoms of severe weight loss, vomiting, dehydration, and polyuria. He manifested the Toni Debré Fanconi syndrome. Slit lamp examination of the anterior segment of both eyes revealed fine, shiny crystal-like deposits diffusely distributed in the corneal epithelium and the stroma. Our patient had renal failure. At the age of seven, he reached terminal chronic renal failure and was treated with peritoneal dialysis. Hemodialysis was started at the age of nine years. At the age of 13 years, he received a renal transplantation and was started on cysteamine 1999, five months after the renal transplantation. Currently, the patient is 28-year-old. The graft has survived 15 years after the transplantation. Renal functions were stable with a serum creatinine of 123 μmol/L at last follow-up.

  9. Hemodynamic Simulations in Dialysis Access Fistulae

    Science.gov (United States)

    McGah, Patrick; Leotta, Daniel; Beach, Kirk; Riley, James; Aliseda, Alberto

    2010-11-01

    Arteriovenous fistulae are created surgically to provide adequate access for dialysis in patients with End-Stage Renal Disease. It has long been hypothesized that the hemodynamic and mechanical forces (such as wall shear stress, wall stretch, or flow- induced wall vibrations) constitute the primary external influence on the remodeling process. Given that nearly 50% of fistulae fail after one year, understanding fistulae hemodynamics is an important step toward improving patency in the clinic. We perform numerical simulations of the flow in patient-specific models of AV fistulae reconstructed from 3D ultrasound scans with physiologically-realistic boundary conditions also obtained from Doppler ultrasound. Comparison of the flow features in different geometries and configurations e.g. end-to-side vs. side-to-side, with the in vivo longitudinal outcomes will allow us to hypothesize which flow conditions are conducive to fistulae success or failure. The flow inertia and pulsatility in the simulations (mean Re 700, max Re 2000, Wo 4) give rise to complex secondary flows and coherent vortices, further complicating the spatio- temporal variability of the wall pressure and shear stresses. Even in mature fistulae, the anastomotic regions are subjected to non-physiological shear stresses (>10.12pcPa) which may potentially lead to complications.

  10. Examining Depression in Patients on Dialysis.

    Science.gov (United States)

    Treadwell, Allison A

    2017-01-01

    This study measured the prevalence of depression in 39 patients on hemodialysis and peritoneal dialysis in two urban outpatient facilities in the southeastern United States. Additionally, it evaluated the number of patients who sought and scheduled a mental health evaluation after screening and education. The prevalence of mild to severely depressed individuals among participants in this study was 36%, affirming previous findings of depressive symptoms in the ESRD population. Results suggest that patients with ESRD are at a higher risk for depression than the general population. The effects of depression may exacerbate ESRD symptoms, affect treatment adherence, and increase hospitalizations and morbidity. It is likely that screening, diagnosing, and treating depression will be associated with improvement in quality and quantity of life. The practicality of using the screening procedure may improve the detection of depression in this population. However, only a fraction of identified patients in this study pursued further mental health evaluation within the 45-day period. Continued research is needed to identify barriers to seeking mental health consultation and treatment in this community. Copyright© by the American Nephrology Nurses Association.

  11. [Design and application of silver needle-knife].

    Science.gov (United States)

    Sun, Guodong; Shi, Bin; Zhang, Benwu; Xu, Haidong

    2015-04-01

    A silver needle-knife which has the dual function of silver needle and needle-knife is designed. The main components of this silver needle-knife are approximately 50% silver and approximately 50% nichrome. The silver needle-knife is composed of five parts, including needle-knife tail, spiral handle; steering handle, needle-knife body and needle-knife edge. It converges the advantages of needle-knife and silver needle, which can cut loose of diseased tissue and peel adhesion of lesions, but also be heated with moxa cone and thermal therapeutic instrument, and connect with electroacupuncture apparatus. It has the function of warming channel and removing coldness, dispelling wind and eliminating dampness, resolving spasm and relieving pain, dredging the channel and so on. Due to the spiral handle and the steering handle, the operation is easier, which reduces the blindness of cutting and increase the safety. It is mainly used for soft tissue injury, rheumatism and rheumatoid arthritis, as well as degenerative diseases of spine and joint, and it has obvious efficacy on some internal medical diseases.

  12. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  13. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  14. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  15. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  16. Knowledge and Practice of Hemodialysis Amongst Dialysis Nurses.

    Science.gov (United States)

    Manandhar, Dhiraj Narayan; Chhetri, Pramod Kumar; Poudel, Prakash; Baidya, Samir Keshari; Agrawaal, Krishna Kumar

    2017-01-01

    Dialysis nurses should have a good knowledge regarding hemodialysis treatment. The status of Nepalese dialysis nurses on this aspect is unknown. This study was done to assess the knowledge and practice on different aspects of the hemodialysis treatment. We distributed validated questionnaires to the participants in a biannual conference in Kathmandu on 24th September as most of the dialysis nurses attend the event. We calculated mean and standard deviation for continuous variables and frequencies and percentage for the responses and compared counseling with different parameters. Total 94 out of 116 participants who were giving care to dialysis patients were in the study. Total 39 (42%) received formal nursing training in hemodialysis and 71 (78%) respondents always counseled patients regarding fluid intake. A total of 37 (96%) trained nurses always counseled the importance of regular dialysis. Seventy-six (81.7%) respondents did counseling on vaccination against Hepatitis B. Counseling on vaccination against influenza and pneumococcus was 47 (50%). When comparing educational status, respondents below bachelor level did more frequent counseling than level above (P=0.03). All the respondents knew the importance of hand washing and BP monitoring during hemodialysis. Ninety-one (96.7%) respondents knew how to deal with BP changes during hemodialysis. Seventy-three (77.6%) respondents were very confident on managing complications. Only 31 (33%) respondents knew how to deal with patients on continuous ambulatory peritoneal dialysis. Dialysis nurses have knowledge on basic procedures of hemodialysis but there is a space for improvement in dealing with complications to provide quality service to hemodialysis patients.

  17. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    Science.gov (United States)

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  18. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  19. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  20. Risk of needle stick injuries in health care workers: bad habits (recapping needles) last long.

    Science.gov (United States)

    Rogowska-Szadkowska, Dorota; Stanisławowicz, Małgorzata; Chlabicz, Sławomir

    2010-01-01

    In order to assess the nurses' knowledge concerning the risk of hepatitis B and C viruses or human immunodeficiency virus infection while performing their professional duties, an anonymous questionnaire developed by the authors was distributed in 2008. Surprisingly 64% respondents occasionally recapping needles after injections, although they know the procedures which are obligatory at the ward. The first step in preventing percutaneous injuries should focus on efforts to eliminate the practice of recapping needles, though education and convenient placement of puncture-resistant containers for the disposal of used sharps.

  1. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  2. Comparison of specimen adequacy in fine needle aspiration cytology performed with different gauge needles in palpable external swellings

    International Nuclear Information System (INIS)

    Sarfraz, T.; Bashir, S.; Tariq, H.; Malik, T.M.

    2013-01-01

    Background: Fine Needle Aspiration Cytology (FNAC) of external swellings may yield different specimen adequacy depending on different gauge needles used for aspiration. Objective: To compare the specimen adequacy aspirated by various gauge (21 and 22) needles in external palpable swellings of lymph nodes, thyroid gland, salivary glands, breast and soft tissue. Study Design: Comparative cross sectional study. Duration: Six months (1st Jan 2012 to 30th June 2012). Setting: Histopathology/Cytology department Combined Military Hospital Peshawar (Pakistan). Methodology: This was a prospective study of 200 cases in which FNAC was performed with either 21 or 22 gauge needles (100 cases with 21 gauge and 100 with 22 gauge needles). Equal number of aspirations were done with 21 and 22 gauge needles from the swellings of thyroid gland, lymph nodes, salivary glands, breast and soft tissue. Results were analyzed for specimen adequacy by using SPSS 17. Results: A total number of 200 cases were recruited in this study, out of which 100 were aspirated with 21 gauge needles and 100 with 22 gauge needles. Specimen adequacy in swellings of thyroid, lymph nodes and salivary glands was better with 22 gauge amounting 90%, 80% and 80% respectively, as compared to yield with 21 gauge needles which was 85%, 70% and 60% respectively. On the other hand in swellings of breast and soft tissue, the specimen adequacy was better with 21 gauge needles giving 98% and 90 % adequate yield respectively as compared to 22 gauge needles which was 70% and 40 % respectively. Conclusion: Needles of smaller gauge (22 gauge) give a better yield in swellings of thyroid, lymph nodes and salivary gland while in swellings of breast and soft tissue sample adequacy is better with larger gauge needle (21 gauge). (author)

  3. Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance

    Science.gov (United States)

    Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.

    2017-01-01

    Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026

  4. Vitamins in dialysis: who, when and how much?

    Science.gov (United States)

    Kosmadakis, George; Da Costa Correia, Enrique; Carceles, Odette; Somda, Frederic; Aguilera, Didier

    2014-05-01

    Despite the significant technical evolution of the blood purification methods, cardiovascular morbidity and mortality in dialysis patients is still several times higher than that observed in the general population. Vitamins are playing a crucial role in multiple key metabolic pathways. Due to multiple factors, dialysis patients present very often hypo- or hypervitaminosis for a broad range of vitamins. Dialysis in the context of renal replacement therapy is associated with a non-physiological potassium-sparing dietetic regime. Additionally, there is a non-selective intradialytic loss of micro- and macronutrients, deranged intracellular kinetics and gastrointestinal malabsorption due to uratemia. Frequent treatment with antibiotics due to infections associated with the acquired uremia-related immunosuppression may derange the vitamin-producing intestinal microflora. Certain agents prescribed in the context of renal failure or other conditions may reduce the absorption of vitamins from the gastrointestinal tract. These factors may deplete a dialysis patient from vitamins, especially the ones with antioxidant activity that may be associated with cardioprotective properties. In other cases, vitamins metabolized and excreted by the kidneys may be accumulated and exert toxic effects. The scope of this paper is to describe the main issues on vitamin therapy in dialysis patients in view of the ever contradictory opinions and practices.

  5. Reduction in slow intercompartmental clearance of urea during dialysis

    International Nuclear Information System (INIS)

    Bowsher, D.J.; Krejcie, T.C.; Avram, M.J.; Chow, M.J.; Del Greco, F.; Atkinson, A.J. Jr.

    1985-01-01

    The kinetics of urea and inulin were analyzed in five anesthetized dogs during sequential 2-hour periods before, during, and after hemodialysis. The distribution of both compounds after simultaneous intravenous injection was characterized by three-compartment models, and the total volumes of urea (0.66 +/- 0.05 L/kg) and inulin (0.19 +/- 0.01 L/kg) distribution were similar to expected values for total body water and extravascular space, respectively. Intercompartmental clearances calculated before dialysis were used to estimate blood flows to the fast and slow equilibrating compartments. In agreement with previous results, the sum of these flows was similar to cardiac output, averaging 101% of cardiac output measured before dialysis (range 72% to 135%). Dialysis was accompanied by reductions in the slow intercompartmental clearances of urea (81%) and inulin (47%), which reflected a 90% attenuation in blood flow supplying the slow equilibrating compartments. This was estimated to result in a 10% average reduction in the efficiency with which urea was removed by dialysis (range 2.0% to 16.4%). Mean arterial pressure fell by less than 5% during dialysis, but total peripheral resistance increased by 47% and cardiac output fell by 35%. In the postdialysis period, total peripheral resistance and cardiac output returned toward predialysis values, but blood flow to the slow equilibrating peripheral compartment was still reduced by 80%. These changes parallel activation of the renin-angiotensin system, but further studies are required to establish causality

  6. Disruptive technological advances in vascular access for dialysis: an overview.

    Science.gov (United States)

    Yeo, Wee-Song; Ng, Qin Xiang

    2017-11-29

    End-stage kidney disease (ESKD), one of the most prevalent diseases in the world and with increasing incidence, is associated with significant morbidity and mortality. Current available modes of renal replacement therapy (RRT) include dialysis and renal transplantation. Though renal transplantation is the preferred and ideal mode of RRT, this modality may not be available to all patients with ESKD. Moreover, renal transplant recipients are constantly at risk of complications associated with immunosuppression and immunosuppressant use, and posttransplant lymphoproliferative disorder. Dialysis may be the only available modality in certain patients. However, dialysis has its limitations, which include issues associated with lack of vascular access, risks of infections and vascular thrombosis, decreased quality of life, and absence of biosynthetic functions of the kidney. In particular, the creation and maintenance of hemodialysis vascular access in children poses a unique set of challenges to the pediatric nephrologist owing to the smaller vessel diameters and vascular hyperreactivity compared with adult patients. Vascular access issues continue to be one of the major limiting factors prohibiting the delivery of adequate dialysis in ESKD patients and is the Achilles' heel of hemodialysis. This review aims to provide a critical overview of disruptive technological advances and innovations for vascular access. Novel strategies in preventing neointimal hyperplasia, novel bioengineered products, grafts and devices for vascular access will be discussed. The potential impact of these solutions on improving the morbidity encountered by dialysis patients will also be examined.

  7. Insomnia in chronic renal patients on dialysis in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Al-Hejaili Fayez F

    2010-06-01

    Full Text Available Abstract Background Studies have shown that insomnia is a common sleep disorder among patients with end-stage renal disease (ESRD. This study aimed to assess the prevalence of insomnia in Saudi patients with ESRD who are on maintenance dialysis. Methods This was an observational cross-sectional study carried out over a period of five months in two hemodialysis centers in Saudi Arabia. To assess the prevalence of insomnia, we used the ICSD-2 definition. We also examined the association between insomnia and other sleep disorders, the underlying causes of renal failure, dialysis duration, dialysis shift, and other demographic data. Results Out of 227 enrolled patients, insomnia was reported by 60.8%. The mean patient age was 55.7 ± 17.2 years; 53.7% were male and 46.3% were female. Insomnia was significantly associated with female gender, afternoon hemodialysis, Restless Legs Syndrome, high risk for obstructive Sleep Apnea Syndrome and excessive daytime sleepiness (P-values: 0.05, 0.01, Conclusion Insomnia is common in dialysis patients and was significantly associated with other sleep disorders. Greater attention needs to be given to the care of dialysis patients with regard to the diagnosis and management of insomnia and associated sleep disorders.

  8. Intermittent Oral Versus Intravenous Alfacalcidol in Dialysis Patients

    Directory of Open Access Journals (Sweden)

    Mitwalli Ahmed

    2000-01-01

    Full Text Available Patients with end-stage renal failure (ESRF on maintenance dialysis, commonly develop secondary hyperparathyroidism and renal osteodystrophy (ROD. Alfacalcidol, taken orally or administered intravenously, is known to reverse these complications. In this study, 19 ESRF patients, who were on dialysis (13 on hemodialysis and six on peritoneal dialysis for longer than six months and having serum parathormone levels at least four times normal and serum calcium less than 2.1 mmol/L, were randomly allocated to treatment with oral or intravenous (i.v. alfacalcidol for a period of 12 months. There were six patients on hemodialysis (HD and three on peritoneal dialysis (PD in the oral treatment group while in the i.v. group there were seven patients on HD and three on PD. Clinical and serial biochemical assessments showed no statistically significant difference between the orally- and i.v.-treated patients in terms of suppressing secondary hyperparathyroidism and osteodystrophy. However, patients with features of mild ROD on bone histology, had more satisfactory changes in biochemistry when compared to others. Our results further support the use of intermittent oral alfacalcidol in ESRF patients because of its cost effectiveness, ease of administration and convenience, especially for peritoneal dialysis patients.

  9. Mineral Metabolic Abnormalities and Mortality in Dialysis Patients

    Directory of Open Access Journals (Sweden)

    Masanori Abe

    2013-03-01

    Full Text Available The survival rate of dialysis patients, as determined by risk factors such as hypertension, nutritional status, and chronic inflammation, is lower than that of the general population. In addition, disorders of bone mineral metabolism are independently related to mortality and morbidity associated with cardiovascular disease and fracture in dialysis patients. Hyperphosphatemia is an important risk factor of, not only secondary hyperparathyroidism, but also cardiovascular disease. On the other hand, the risk of death reportedly increases with an increase in adjusted serum calcium level, while calcium levels below the recommended target are not associated with a worsened outcome. Thus, the significance of target levels of serum calcium in dialysis patients is debatable. The consensus on determining optimal parathyroid function in dialysis patients, however, is yet to be established. Therefore, the contribution of phosphorus and calcium levels to prognosis is perhaps more significant. Elevated fibroblast growth factor 23 levels have also been shown to be associated with cardiovascular events and death. In this review, we examine the associations between mineral metabolic abnormalities including serum phosphorus, calcium, and parathyroid hormone and mortality in dialysis patients.

  10. Evaluating the advances and use of hypodermic needles in dentistry.

    Science.gov (United States)

    Boynes, Sean G

    2014-10-01

    Different injection techniques and patient management methodologies have been proposed to decrease the fear patients may have concerning dental needles. Dental providers should have an understanding of the technological advances, changes in techniques, and patient perceptions associated with the hypodermic needle. This article provides an overview of the pain perception process associated with dental injections. It reviews the two main sensory nerve fibers associated with injection pain and discusses needle properties as well as complications and adverse occurrences.

  11. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  12. Polymer nanocomposites: polymer and particle dynamics

    KAUST Repository

    Kim, Daniel; Srivastava, Samanvaya; Narayanan, Suresh; Archer, Lynden A.

    2012-01-01

    Polymer nanocomposites containing nanoparticles smaller than the random coil size of their host polymer chains are known to exhibit unique properties, such as lower viscosity and glass transition temperature relative to the neat polymer melt. It has

  13. Antimocrobial Polymer

    Science.gov (United States)

    McDonald, William F.; Huang, Zhi-Heng; Wright, Stacy C.

    2005-09-06

    A polymeric composition having antimicrobial properties and a process for rendering the surface of a substrate antimicrobial are disclosed. The composition comprises a crosslinked chemical combination of (i) a polymer having amino group-containing side chains along a backbone forming the polymer, (ii) an antimicrobial agent selected from quaternary ammonium compounds, gentian violet compounds, substituted or unsubstituted phenols, biguanide compounds, iodine compounds, and mixtures thereof, and (iii) a crosslinking agent containing functional groups capable of reacting with the amino groups. In one embodiment, the polymer is a polyamide formed from a maleic anhydride or maleic acid ester monomer and alkylamines thereby producing a polyamide having amino substituted alkyl chains on one side of the polyamide backbone; the crosslinking agent is a phosphine having the general formula (A)3P wherein A is hydroxyalkyl; and the antimicrobial agent is chlorhexidine, dimethylchlorophenol, cetyl pyridinium chloride, gentian violet, triclosan, thymol, iodine, and mixtures thereof.

  14. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  15. The glycogen of Galdieria sulphuraria as alternative to starch for the production of slowly digestible and resistant glucose polymers

    NARCIS (Netherlands)

    Martinez-Garcia, Marta; Kormpa, Akrivi; van der Maarel, Marc J. E. C.

    2017-01-01

    Highly branched glucose polymers produced from starch are applied in various products, such as peritoneal dialysis solutions and sports drinks. Due to its insoluble, granular nature, the use of native starch as substrate requires an energy consuming pre-treatment to achieve solubilization at the

  16. [Percutaneous needle aponeurotomy for Dupuytren's disease].

    Science.gov (United States)

    Spies, C K; Müller, L P; Skouras, E; Bassemir, D; Hahn, P; Unglaub, F

    2016-02-01

    Percutaneous transverse aponeurotomy of the cord by using a hypodermic needle as a scalpel blade in order to improve function of the hand. Symptomatic flexion contracture with positive table top test caused by a single, palpable cord within the palm (primarily Tubiana stages I and II). Multiple, infiltrating or broad-based cords within the palm; irritated skin conditions; exclusive digital cord localization; recurrence after aponeurectomy; previous surgical intervention at the site of interest, digital nerve lesions; lack of patient compliance. Pinpoint surface anesthesia is obtained by injecting each portal area subdermally with 0.1 ml of local anesthetic. These applications start from distally to proximally within the palm while the most distal injection site is located proximal to the distal palm crease. Then the needle tip is introduced perpendicular to the cord. Sawing movements through the cord are performed transversely. While passively extending the contracted finger, the cord is held under tension which guarantees safe cutting. Patients are encouraged to report immediate pain sensation or numbness in order to prevent injuries to neurovascular structures and active finger flexion excludes tendon lesions during the procedure. Introducing the needle tip may be performed at several sites along the cord, if necessary, from distal to proximal at least 5 mm apart with prior pinpoint surface anesthesia. Finally, cautious passive stretching may be done after each release. Bandaging allowing immediate motion; application of a hand-based extension splint-glove during the night for 3-6 months. Recurrence rate was 53% in 15 retrospectively examined patients after a mean interval of 40 months postoperatively.

  17. Polymer electronics

    CERN Document Server

    Geoghegan, Mark

    2013-01-01

    Polymer electronics is the science behind many important new developments in technology, such as the flexible electronic display (e-ink) and many new developments in transistor technology. Solar cells, light-emitting diodes, and transistors are all areas where plastic electronics is likely to, or is already having, a serious impact on our daily lives. With polymer transistors and light-emitting diodes now being commercialised, there is a clear need for a pedagogic text thatdiscusses the subject in a clear and concise fashion suitable for senior undergraduate and graduate students. The content

  18. Frailty in Chinese Peritoneal Dialysis Patients: Prevalence and Prognostic Significance

    Directory of Open Access Journals (Sweden)

    Jack Kit-Chung Ng

    2016-10-01

    Full Text Available Background/Aims: Previous studies showed that frailty is prevalent in both pre-dialysis and dialysis patients. However, the prevalence and prognostic implication of frailty in Chinese peritoneal dialysis (PD patients remain unknown. Methods: We used a validated questionnaire to determine the Frailty Score of 193 unselected prevalent PD patients. All patients were then followed for 2 years for their need of hospitalization and mortality. Results: Amongst the 193 patients, 134 (69.4% met the criteria of being frail. Frailty Score significantly correlated with Charlson's comorbidity score (r = 0.40, p Conclusions: Frailty is prevalent among Chinese PD patients. Frail PD patients have a high risk of requiring hospitalization and their hospital stay tends to be prolonged. Early identification may allow timely intervention to prevent adverse health outcomes in this group of patients.

  19. Challenges of ECG monitoring and ECG interpretation in dialysis units.

    Science.gov (United States)

    Poulikakos, Dimitrios; Malik, Marek

    Patients on hemodialysis (HD) suffer from high cardiovascular morbidity and mortality due to high rates of coronary artery disease and arrhythmias. Electrocardiography (ECG) is often performed in the dialysis units as part of routine clinical assessment. However, fluid and electrolyte changes have been shown to affect all ECG morphologies and intervals. ECG interpretation thus depends on the time of the recording in relation to the HD session. In addition, arrhythmias during HD are common, and dialysis-related ECG artifacts mimicking arrhythmias have been reported. Studies using advanced ECG analyses have examined the impact of the HD procedure on selected repolarization descriptors and heart rate variability indices. Despite the challenges related to the impact of the fluctuant fluid and electrolyte status on conventional and advanced ECG parameters, further research in ECG monitoring during dialysis has the potential to provide clinically meaningful and practically useful information for diagnostic and risk stratification purposes. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  20. Tailoring peritoneal dialysis fluid for optimal acid-base targets.

    Science.gov (United States)

    Feriani, Mariano

    2009-01-01

    Mild derangements of acid-base status are common features in peritoneal dialysis patients, metabolic acidosis being the most frequent alteration. One of the main tasks of dialysis is to correct these derangements and the target is the normalization of the acid-base parameters since they affect several organs and functions. Since factors affecting acid-base homeostasis are intrinsic characteristics of the individual patient (metabolic acid production, distribution space for bicarbonate, dialytic prescription, etc.), it is not surprising that only relatively few patients achieve the normal range. Only a certain modulation of buffer infusion by using different buffer concentrations in the dialysis fluid may ensure a good correction in a large percentage of patients.

  1. Examination of dialysis patients with the aminophenazone breath test

    International Nuclear Information System (INIS)

    Heinrich, H.G.; Adler, D.; Hornak, H.; Wuenschmann, H.J.; Mayer, W.K.

    1989-01-01

    In 12 endstage kidney disease patients (8 without and 4 with liver diseases) the activities of cytochrome P 450 -dependent mixed functional oxidases system (MFO) of the liver were studied by using the 14 C-aminophenazone breath test before and after dialysis. The results showed that uremia seems to have a pressing influence on MFO activity. The activity was only significantly increased after dialysis in the group of patients without liver diseases. The MFO activity was reduced in patients with liver diseases. This is a restriction of the hepatic metabolic demethylation capacity. It is unclear if the 14 C-aminophenazone breath test in dialysis patients is qualified to estimate metabolic capacity of the liver. Differentiation between the influence of uremia and of the liver disease on the alteration of MFO activity cannot be made. (author)

  2. Nonadherence in dialysis patients: prevalence, measurement, outcome, and psychological determinants.

    Science.gov (United States)

    Clark, Sarah; Farrington, Ken; Chilcot, Joseph

    2014-01-01

    Nonadherence to aspects of the management of End-Stage Kidney Disease (ESKD) is common. Estimates of nonadherence vary with assessment method. Whilst readily available and free from report bias, physiological proxies-frequently used as measures of adherence-are often confounded by clinical factors including residual kidney function and dialysis adequacy. Despite variation in estimates of its prevalence, it is clear that suboptimal adherence to dialysis prescriptions, medication and diet can lead to adverse clinical outcomes. Several factors can help explain nonadherence in ESKD including mood, self-efficacy, social support, illness, and treatment perceptions. Psychological interventions have been shown to improve ESKD adherence, yet achieving long-term behavior change remains challenging. Identifying individuals who struggle to adhere to aspects of the dialysis regime, and tailoring theory-led interventions to improve and support adherence is a clear clinical need requiring further empirical enquiry. © 2013 Wiley Periodicals, Inc.

  3. Comparison of outcomes for veterans receiving dialysis care from VA and non-VA providers

    Directory of Open Access Journals (Sweden)

    Wang Virginia

    2013-01-01

    Full Text Available Abstract Background Demand for dialysis treatment exceeds its supply within the Veterans Health Administration (VA, requiring VA to outsource dialysis care by purchasing private sector dialysis for veterans on a fee-for-service basis. It is unclear whether outcomes are similar for veterans receiving dialysis from VA versus non-VA providers. We assessed the extent of chronic dialysis treatment utilization and differences in all-cause hospitalizations and mortality between veterans receiving dialysis from VA versus VA-outsourced providers. Methods We constructed a retrospective cohort of veterans in 2 VA regions who received chronic dialysis treatment financed by VA between January 2007 and December 2008. From VA administrative data, we identified veterans who received outpatient dialysis in (1 VA, (2 VA-outsourced settings, or (3 both (“dual” settings. In adjusted analyses, we used two-part and logistic regression to examine associations between dialysis setting and all-cause hospitalization and mortality one-year from veterans’ baseline dialysis date. Results Of 1,388 veterans, 27% received dialysis exclusively in VA, 47% in VA-outsourced settings, and 25% in dual settings. Overall, half (48% were hospitalized and 12% died. In adjusted analysis, veterans in VA-outsourced settings incurred fewer hospitalizations and shorter hospital stays than users of VA due to favorable selection. Dual-system dialysis patients had lower one-year mortality than veterans receiving VA dialysis. Conclusions VA expenditures for “buying” outsourced dialysis are high and increasing relative to “making” dialysis treatment within its own system. Outcomes comparisons inform future make-or-buy decisions and suggest the need for VA to consider veterans’ access to care, long-term VA savings, and optimal patient outcomes in its placement decisions for dialysis services.

  4. Comparison of outcomes for veterans receiving dialysis care from VA and non-VA providers.

    Science.gov (United States)

    Wang, Virginia; Maciejewski, Matthew L; Patel, Uptal D; Stechuchak, Karen M; Hynes, Denise M; Weinberger, Morris

    2013-01-18

    Demand for dialysis treatment exceeds its supply within the Veterans Health Administration (VA), requiring VA to outsource dialysis care by purchasing private sector dialysis for veterans on a fee-for-service basis. It is unclear whether outcomes are similar for veterans receiving dialysis from VA versus non-VA providers. We assessed the extent of chronic dialysis treatment utilization and differences in all-cause hospitalizations and mortality between veterans receiving dialysis from VA versus VA-outsourced providers. We constructed a retrospective cohort of veterans in 2 VA regions who received chronic dialysis treatment financed by VA between January 2007 and December 2008. From VA administrative data, we identified veterans who received outpatient dialysis in (1) VA, (2) VA-outsourced settings, or (3) both ("dual") settings. In adjusted analyses, we used two-part and logistic regression to examine associations between dialysis setting and all-cause hospitalization and mortality one-year from veterans' baseline dialysis date. Of 1,388 veterans, 27% received dialysis exclusively in VA, 47% in VA-outsourced settings, and 25% in dual settings. Overall, half (48%) were hospitalized and 12% died. In adjusted analysis, veterans in VA-outsourced settings incurred fewer hospitalizations and shorter hospital stays than users of VA due to favorable selection. Dual-system dialysis patients had lower one-year mortality than veterans receiving VA dialysis. VA expenditures for "buying" outsourced dialysis are high and increasing relative to "making" dialysis treatment within its own system. Outcomes comparisons inform future make-or-buy decisions and suggest the need for VA to consider veterans' access to care, long-term VA savings, and optimal patient outcomes in its placement decisions for dialysis services.

  5. Types of vicarious learning experienced by pre-dialysis patients

    Directory of Open Access Journals (Sweden)

    Kate McCarthy

    2015-04-01

    Full Text Available Objective: Haemodialysis and peritoneal dialysis renal replacement treatment options are in clinical equipoise, although the cost of haemodialysis to the National Health Service is £16,411/patient/year greater than peritoneal dialysis. Treatment decision-making takes place during the pre-dialysis year when estimated glomerular filtration rate drops to between 15 and 30 mL/min/1.73 m2. Renal disease can be familial, and the majority of patients have considerable health service experience when they approach these treatment decisions. Factors affecting patient treatment decisions are currently unknown. The objective of this article is to explore data from a wider study in specific relation to the types of vicarious learning experiences reported by pre-dialysis patients. Methods: A qualitative study utilised unstructured interviews and grounded theory analysis during the participant’s pre-dialysis year. The interview cohort comprised 20 pre-dialysis participants between 24 and 80 years of age. Grounded theory design entailed thematic sampling and analysis, scrutinised by secondary coding and checked with participants. Participants were recruited from routine renal clinics at two local hospitals when their estimated glomerular filtration rate was between 15 and 30 mL/min/1.73 m2. Results: Vicarious learning that contributed to treatment decision-making fell into three main categories: planned vicarious leaning, unplanned vicarious learning and historical vicarious experiences. Conclusion: Exploration and acknowledgement of service users’ prior vicarious learning, by healthcare professionals, is important in understanding its potential influences on individuals’ treatment decision-making. This will enable healthcare professionals to challenge heuristic decisions based on limited information and to encourage analytic thought processes.

  6. Types of vicarious learning experienced by pre-dialysis patients.

    Science.gov (United States)

    McCarthy, Kate; Sturt, Jackie; Adams, Ann

    2015-01-01

    Haemodialysis and peritoneal dialysis renal replacement treatment options are in clinical equipoise, although the cost of haemodialysis to the National Health Service is £16,411/patient/year greater than peritoneal dialysis. Treatment decision-making takes place during the pre-dialysis year when estimated glomerular filtration rate drops to between 15 and 30 mL/min/1.73 m(2). Renal disease can be familial, and the majority of patients have considerable health service experience when they approach these treatment decisions. Factors affecting patient treatment decisions are currently unknown. The objective of this article is to explore data from a wider study in specific relation to the types of vicarious learning experiences reported by pre-dialysis patients. A qualitative study utilised unstructured interviews and grounded theory analysis during the participant's pre-dialysis year. The interview cohort comprised 20 pre-dialysis participants between 24 and 80 years of age. Grounded theory design entailed thematic sampling and analysis, scrutinised by secondary coding and checked with participants. Participants were recruited from routine renal clinics at two local hospitals when their estimated glomerular filtration rate was between 15 and 30 mL/min/1.73 m(2). Vicarious learning that contributed to treatment decision-making fell into three main categories: planned vicarious leaning, unplanned vicarious learning and historical vicarious experiences. Exploration and acknowledgement of service users' prior vicarious learning, by healthcare professionals, is important in understanding its potential influences on individuals' treatment decision-making. This will enable healthcare professionals to challenge heuristic decisions based on limited information and to encourage analytic thought processes.

  7. Phosphate binding therapy in dialysis patients: focus on lanthanum carbonate

    Directory of Open Access Journals (Sweden)

    Ismail A Mohammed

    2008-11-01

    Full Text Available Ismail A Mohammed, Alastair J HutchisonManchester Institute of Nephrology and Transplantation, Manchester Royal Infirmary, Oxford Road, Manchester, UKAbstract: Hyperphosphatemia is an inevitable consequence of end stage chronic kidney disease and is present in the majority of dialysis patients. Recent observational data has associated hyperphosphatemia with increased cardiovascular mortality among dialysis patients. Dietary restriction of phosphate and current dialysis prescription practices are not enough to maintain serum phosphate levels within the recommended range so that the majority of dialysis patients require oral phosphate binders. Unfortunately, conventional phosphate binders are not reliably effective and are associated with a range of limitations and side effects. Aluminium-containing agents are highly efficient but no longer widely used because of well established and proven toxicity. Calcium based salts are inexpensive, effective and most widely used but there is now concern about their association with hypercalcemia and vascular calcification. Sevelamer hydrochloride is associated with fewer adverse effects, but a large pill burden and high cost are limiting factors to its wider use. In addition, the efficacy of sevelamer as a monotherapy in lowering phosphate to target levels in severe hyperphosphatemia remains debatable. Lanthanum carbonate is a promising new non-aluminium, calcium-free phosphate binder. Preclinical and clinical studies have demonstrated a good safety profile, and it appears well tolerated and effective in reducing phosphate levels in dialysis patients. Its identified adverse events are apparently mild to moderate in severity and mostly GI related. It appears to be effective as a monotherapy, with a reduced pill burden, but like sevelamer, it is significantly more expensive than calcium-based binders. Data on its safety profile over 6 years of treatment are now available.Keywords: hyperphosphatemia, lanthanum

  8. Albumin Dialysis for Liver Failure: A Systematic Review.

    Science.gov (United States)

    Tsipotis, Evangelos; Shuja, Asim; Jaber, Bertrand L

    2015-09-01

    Albumin dialysis is the best-studied extracorporeal nonbiologic liver support system as a bridge or destination therapy for patients with liver failure awaiting liver transplantation or recovery of liver function. We performed a systematic review to examine the efficacy and safety of 3 albumin dialysis systems (molecular adsorbent recirculating system [MARS], fractionated plasma separation, adsorption and hemodialysis [Prometheus system], and single-pass albumin dialysis) in randomized trials for supportive treatment of liver failure. PubMed, Ovid, EMBASE, Cochrane's Library, and ClinicalTrials.gov were searched. Two authors independently screened citations and extracted data on patient characteristics, quality of reports, efficacy, and safety end points. Ten trials (7 of MARS and 3 of Prometheus) were identified (620 patients). By meta-analysis, albumin dialysis achieved a net decrease in serum total bilirubin level relative to standard medical therapy of 8.0 mg/dL (95% confidence interval [CI], -10.6 to -5.4) but not in serum ammonia or bile acids. Albumin dialysis achieved an improvement in hepatic encephalopathy relative to standard medical therapy with a risk ratio of 1.55 (95% CI, 1.16-2.08) but had no effect survival with a risk ratio of 0.95 (95% CI, 0.84-1.07). Because of inconsistency in the reporting of adverse events, the safety analysis was limited but did not demonstrate major safety concerns. Use of albumin dialysis as supportive treatment for liver failure is successful at removing albumin-bound molecules, such as bilirubin and at improving hepatic encephalopathy. Additional experience is required to guide its optimal use and address safety concerns. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  9. Polymer poling characterization using second harmonic generation (SHG)

    Science.gov (United States)

    Tellier, Gildas; Averty, Dominique; Blart, Errol; Boisrobert, Christian; Gundel, Hartmut; Le Tacon, Sylvain; Monnereau, Cyrille; Odobel, Fabrice; Seveno, Raynald

    2006-04-01

    Several polymer molecules have structures which are suitable for the non-linear optic applications. We report on the design and fabrication of a high performance electro-optic modulator made of polymer thin films. The polymer we study contains a chromophore based on Disperse Red One covalently grafted to a host-matrix. The polymer materials are deposited in thin layers on a glass substrate by chemical solution deposition, either by spin-coating or by dip-coating. The thickness of the films is ranging from a hundred nanometers to several micrometers. Initially, the polymer molecules are randomly oriented and the films are isotropic, hence no electro-optic effect can be observed. In order to break the symmetry and align the chromophores, the films are submitted to the so-called corona poling process. As a result, their structure become non-centrosymmetric and the second-order susceptibility is no longer zero. The corona poling method consists of applying a high electric field to the polymer by means of a needle electrode, placed above the polymer film which is posed on a grounded sample support electrode. Thermal regulation of the support electrode allows to control the temperature during the poling of the films. Once the poling process has been established, a chemical cross-linking function is thermally activated in order to fix the orientation of the chromophores in the polymer matrix. The orientation and its stability in time is evaluated with a Second Harmonic Generation measurement set-up using the Makers Fringes configuration. We studied the influence of the poling temperature, the distance between the corona needle electrode and the sample, the high voltage applied, and the duration of the poling process on the efficiency of chromophore orientation in order to optimize the poling procedure. Finally, aging of poled polymer samples has been investigated at elevated temperatures, confirming the stability of the cross-linking process.

  10. How to preserve residual renal function in patients with chronic kidney disease and on dialysis?

    NARCIS (Netherlands)

    Krediet, Raymond T.

    2006-01-01

    A review is given on various aspects of GFR in patients with chronic kidney disease and in dialysis patients. These include the measurement of GFR, measures to preserve GFR in chronic kidney disease and dialysis, the importance of residual GFR in dialysis patients and factors that influence GFR in

  11. Is protein-energy intake adequate during dialysis treatment in hemodialysis patients ?

    Directory of Open Access Journals (Sweden)

    Trudeke (G I. Struijk-Wielinga

    2012-06-01

    Conclusion: Protein and energy intake of hemodialysis patients is lower than their daily needs. On non dialysis days intake is even lower than on dialysis days. The meals consumed during dialysis treatment contain enough energy but not enough protein to meet requirements.

  12. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  13. Effect and safety of deep needling and shallow needling for functional constipation: a multicenter, randomized controlled trial.

    Science.gov (United States)

    Wu, Jiani; Liu, Baoyan; Li, Ning; Sun, Jianhua; Wang, Lingling; Wang, Liping; Cai, Yuying; Ye, Yongming; Liu, Jun; Wang, Yang; Liu, Zhishun

    2014-12-01

    Aupuncture is widely used for functional constipation. Effect of acupuncture might be related to the depth of needling; however, the evidence is limited. This trial aimed to evaluate the effect and safety of deep needling and shallow needling for functional constipation, and to assess if the deep needling and shallow needling are superior to lactulose. We conducted a prospective, superiority-design, 5-center, 3-arm randomized controlled trial. A total of 475 patients with functional constipation were randomized to the deep needling group (237), shallow needling group (119), and lactulose-controlled group (119) in a ratio of 2:1:1. Sessions lasted 30 minutes each time and took place 5 times a week for 4 weeks in 2 acupuncture groups. Participants in the lactulose group took lactulose orally for 16 continuous weeks. The primary outcome was the change from baseline of mean weekly spontaneous bowel movements (SBMs) during week 1 to 4 (changes from the baselines of the weekly SBMs at week 8 and week 16 in follow-up period were also assessed simultaneously). Secondary outcomes were the weekly SBMs of each assessing week, the mean score change from the baseline of constipation-related symptoms over week 1 to 4, and the time to the first SBM. Emergency drug usage and adverse effects were monitored throughout the study.SBMs and constipation-related symptoms were all improved in the 3 groups compared with baseline at each time frame (Pdeep needling group, 2 (1.75) in the shallow needling group, and 2 (2) in the lactulose group (P>0.05, both compared with the lactulose group). The changes of mean weekly SBMs at week 8 and week 16 in the follow-up period were 2 (2), 2 (2.5) in the deep needling group, 2 (3), 1.5 (2.5) in the shallow needling group, and 1 (2), 1 (2) in the lactulose group (Pdeep or shallow needling group. Deep and shallow needling at Tianshu (ST25) can improve intestinal function remarkably and safely. Therapeutic effects of deep and shallow needling are not

  14. Fate of patients during the first year of dialysis

    Directory of Open Access Journals (Sweden)

    Selma Siham El Khayat

    2013-01-01

    Full Text Available Care in dialysis is often associated with significant morbidity and mortality during the first year. Knowledge of its magnitude and causes could improve the prognosis of these patients. The aim of this study was to evaluate the survival and morbidity during the first year of dialysis for patients who initiated their dialysis between January 1, 2009 and December 31, 2009 and to study their possible correlation with baseline status at the beginning of treatment. A multi-center retrospective study was conducted in 11 dialysis centers. Clinical data at the beginning of dialysis and during the following year were collected. Mortality and morbidity risk factors were assessed by comparing different groups. Statistical analysis was performed with SPSS version 11. This study involved 134 patients, 79 men and 55 women, of whom 132 were on hemodialysis and two patients were on peritoneal dialysis. The mean age at initiation of treatment was 54.37 ± 18.09 years. Initial causes of nephropathy were dominated by diabetes (44.02% and hypertension (11.19%. Among these patients, 39.55% had never received prior nephrological follow-up and 64.92% had started renal replacement therapy on an emergency basis. The initial clinical state was dominated by the presence of hypertension (50.74%, diabetes (44.02%, coronary insufficiency (13.43% and heart failure (7.46%. Only 26.86% of the incident patients showed no comorbidity. During the first year of follow-up, 37.31% of the patients experienced at least one episode of comorbidity. Hospitalization was necessary in about half of these cases (17.91% of all patients. The overall mortality rate was 14.17%. One patient received a kidney transplant. The mortality rate in the first year of dialysis was lower in our study than in other series. Regular nephrological follow-up of these patients before they reach end-stage could have a significant influence on survival in dialysis.

  15. Psychological distress and treatment adherence among children on dialysis.

    Science.gov (United States)

    Simoni, J M; Asarnow, J R; Munford, P R; Koprowski, C M; Belin, T R; Salusky, I B

    1997-10-01

    Among 23 pediatric renal dialysis patients, we obtained self-reported assessments of psychological adjustment and biochemical and subjective ratings of adherence. Findings indicate elevated levels of depressive symptoms and substantial nonadherence. Depressive symptoms were associated with higher levels of hopelessness, more negative self-perceptions, and more depressogenic attributional style. The psychological adjustment measures did not significantly correlate with adherence. Nonsignificant associations among different measures of adherence underscore its multifaceted nature. Implications for monitoring the adjustment of children on dialysis, assessing adherence, and future research are discussed.

  16. Brain gamma-aminobutyric acid deficiency in dialysis encephalopathy.

    Science.gov (United States)

    Sweeney, V P; Perry, T L; Price, J D; Reeve, C E; Godolphin, W J; Kish, S J

    1985-02-01

    We measured levels of gamma-aminobutyric acid (GABA) in the CSF and in the autopsied brain of patients with dialysis encephalopathy. GABA concentrations were low in the CSF of three of five living patients. Mean GABA content was reduced by 30 to 50% in five brain regions (frontal, occipital, and cerebellar cortex, caudate nucleus, and medial dorsal thalamus) in five fatal cases. GABA content was normal in brain regions where GABA is characteristically reduced in Huntington's disease. Choline acetyltransferase activity was diminished (by 25 to 35%) in cerebral cortex of the dialysis encephalopathy patients.

  17. Peritoneal Dialysis Access Revision in Children: Causes, Interventions, and Outcomes.

    Science.gov (United States)

    Borzych-Duzalka, Dagmara; Aki, T Fazil; Azocar, Marta; White, Colin; Harvey, Elizabeth; Mir, Sevgi; Adragna, Marta; Serdaroglu, Erkin; Sinha, Rajiv; Samaille, Charlotte; Vanegas, Juan Jose; Kari, Jameela; Barbosa, Lorena; Bagga, Arvind; Galanti, Monica; Yavascan, Onder; Leozappa, Giovanna; Szczepanska, Maria; Vondrak, Karel; Tse, Kei-Chiu; Schaefer, Franz; Warady, Bradley A

    2017-01-06

    Little published information is available about access failure in children undergoing chronic peritoneal dialysis. Our objectives were to evaluate frequency, risk factors, interventions, and outcome of peritoneal dialysis access revision. Data were derived from 824 incident and 1629 prevalent patients from 105 pediatric nephrology centers enrolled in the International Pediatric Peritoneal Dialysis Network Registry between 2007 and 2015. In total, 452 access revisions were recorded in 321 (13%) of 2453 patients over 3134 patient-years of follow-up, resulting in an overall access revision rate of 0.14 per treatment year. Among 824 incident patients, 186 (22.6%) underwent 188 access revisions over 1066 patient-years, yielding an access revision rate of 0.17 per treatment year; 83% of access revisions in incident patients were reported within the first year of peritoneal dialysis treatment. Catheter survival rates in incident patients were 84%, 80%, 77%, and 73% at 12, 24, 36, and 48 months, respectively. By multivariate logistic regression analysis, risk of access revision was associated with younger age (odds ratio, 0.93; 95% confidence interval, 0.92 to 0.95; P<0.001), diagnosis of congenital anomalies of the kidney and urinary tract (odds ratio, 1.28; 95% confidence interval, 1.03 to 1.59; P=0.02), coexisting ostomies (odds ratio, 1.42; 95% confidence interval, 1.07 to 1.87; P=0.01), presence of swan neck tunnel with curled intraperitoneal portion (odds ratio, 1.30; 95% confidence interval, 1.04 to 1.63; P=0.02), and high gross national income (odds ratio, 1.10; 95% confidence interval, 1.02 to 1.19; P=0.01). Main reasons for access revisions included mechanical malfunction (60%), peritonitis (16%), exit site infection (12%), and leakage (6%). Need for access revision increased the risk of peritoneal dialysis technique failure or death (hazard ratio, 1.35; 95% confidence interval, 1.10 to 1.65; P=0.003). Access dysfunction due to mechanical causes doubled the risk

  18. Peritoneal Dialysis Access Revision in Children: Causes, Interventions, and Outcomes

    Science.gov (United States)

    Aki, T. Fazil; Azocar, Marta; White, Colin; Harvey, Elizabeth; Mir, Sevgi; Adragna, Marta; Serdaroglu, Erkin; Sinha, Rajiv; Samaille, Charlotte; Vanegas, Juan Jose; Kari, Jameela; Barbosa, Lorena; Bagga, Arvind; Galanti, Monica; Yavascan, Onder; Leozappa, Giovanna; Szczepanska, Maria; Vondrak, Karel; Tse, Kei-Chiu; Schaefer, Franz; Warady, Bradley A.

    2017-01-01

    Background and objectives Little published information is available about access failure in children undergoing chronic peritoneal dialysis. Our objectives were to evaluate frequency, risk factors, interventions, and outcome of peritoneal dialysis access revision. Design, setting, participants, & measurements Data were derived from 824 incident and 1629 prevalent patients from 105 pediatric nephrology centers enrolled in the International Pediatric Peritoneal Dialysis Network Registry between 2007 and 2015. Results In total, 452 access revisions were recorded in 321 (13%) of 2453 patients over 3134 patient-years of follow-up, resulting in an overall access revision rate of 0.14 per treatment year. Among 824 incident patients, 186 (22.6%) underwent 188 access revisions over 1066 patient-years, yielding an access revision rate of 0.17 per treatment year; 83% of access revisions in incident patients were reported within the first year of peritoneal dialysis treatment. Catheter survival rates in incident patients were 84%, 80%, 77%, and 73% at 12, 24, 36, and 48 months, respectively. By multivariate logistic regression analysis, risk of access revision was associated with younger age (odds ratio, 0.93; 95% confidence interval, 0.92 to 0.95; P<0.001), diagnosis of congenital anomalies of the kidney and urinary tract (odds ratio, 1.28; 95% confidence interval, 1.03 to 1.59; P=0.02), coexisting ostomies (odds ratio, 1.42; 95% confidence interval, 1.07 to 1.87; P=0.01), presence of swan neck tunnel with curled intraperitoneal portion (odds ratio, 1.30; 95% confidence interval, 1.04 to 1.63; P=0.02), and high gross national income (odds ratio, 1.10; 95% confidence interval, 1.02 to 1.19; P=0.01). Main reasons for access revisions included mechanical malfunction (60%), peritonitis (16%), exit site infection (12%), and leakage (6%). Need for access revision increased the risk of peritoneal dialysis technique failure or death (hazard ratio, 1.35; 95% confidence interval, 1

  19. From the Cover: Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies

    Science.gov (United States)

    McAllister, Devin V.; Wang, Ping M.; Davis, Shawn P.; Park, Jung-Hwan; Canatella, Paul J.; Allen, Mark G.; Prausnitz, Mark R.

    2003-11-01

    Arrays of micrometer-scale needles could be used to deliver drugs, proteins, and particles across skin in a minimally invasive manner. We therefore developed microfabrication techniques for silicon, metal, and biodegradable polymer microneedle arrays having solid and hollow bores with tapered and beveled tips and feature sizes from 1 to 1,000 μm. When solid microneedles were used, skin permeability was increased in vitro by orders of magnitude for macromolecules and particles up to 50 nm in radius. Intracellular delivery of molecules into viable cells was also achieved with high efficiency. Hollow microneedles permitted flow of microliter quantities into skin in vivo, including microinjection of insulin to reduce blood glucose levels in diabetic rats. transdermal drug delivery | skin | microelectromechanical systems | solid microneedle | hollow needle injection

  20. Polymer physics

    CERN Document Server

    Gedde, Ulf W

    1999-01-01

    This book is the result of my teaching efforts during the last ten years at the Royal Institute of Technology. The purpose is to present the subject of polymer physics for undergraduate and graduate students, to focus the fundamental aspects of the subject and to show the link between experiments and theory. The intention is not to present a compilation of the currently available literature on the subject. Very few reference citations have thus been made. Each chapter has essentially the same structure: starling with an introduction, continuing with the actual subject, summarizing the chapter in 30D-500 words, and finally presenting problems and a list of relevant references for the reader. The solutions to the problems presented in Chapters 1-12 are given in Chapter 13. The theme of the book is essentially polymer science, with the exclusion of that part dealing directly with chemical reactions. The fundamentals in polymer science, including some basic polymer chemistry, are presented as an introduction in t...

  1. Antimicrobial polymers.

    Science.gov (United States)

    Jain, Anjali; Duvvuri, L Sailaja; Farah, Shady; Beyth, Nurit; Domb, Abraham J; Khan, Wahid

    2014-12-01

    Better health is basic requirement of human being, but the rapid growth of harmful pathogens and their serious health effects pose a significant challenge to modern science. Infections by pathogenic microorganisms are of great concern in many fields such as medical devices, drugs, hospital surfaces/furniture, dental restoration, surgery equipment, health care products, and hygienic applications (e.g., water purification systems, textiles, food packaging and storage, major or domestic appliances etc.) Antimicrobial polymers are the materials having the capability to kill/inhibit the growth of microbes on their surface or surrounding environment. Recently, they gained considerable interest for both academic research and industry and were found to be better than their small molecular counterparts in terms of enhanced efficacy, reduced toxicity, minimized environmental problems, resistance, and prolonged lifetime. Hence, efforts have focused on the development of antimicrobial polymers with all desired characters for optimum activity. In this Review, an overview of different antimicrobial polymers, their mechanism of action, factors affecting antimicrobial activity, and application in various fields are given. Recent advances and the current clinical status of these polymers are also discussed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. RF Photoelectric injectors using needle cathodes

    International Nuclear Information System (INIS)

    Lewellen, J.W.; Brau, C.A.

    2003-01-01

    Photocathode RF guns, in various configurations, are the injectors of choice for both current and future applications requiring high-brightness electron beams. Many of these applications, such as single-pass free-electron lasers, require beams with high brilliance but not necessarily high charge per bunch. Field-enhanced photoelectric emission has demonstrated electron-beam current density as high as 10 10 A/m 2 , with a quantum efficiency in the UV that approaches 10% at fields on the order of 10 10 V/m. Thus, the use of even a blunt needle holds promise for increasing cathode quantum efficiency without sacrificing robustness. We present an initial study on the use of needle cathodes in photoinjectors to enhance beam brightness while reducing beam charge. Benefits include lower drive-laser power requirements, easier multibunch operation, lower emittance, and lower beam degradation due to charge-dependent effects in the postinjector accelerator. These benefits result from a combination of a smaller cathode emission area, greatly enhanced RF field strength at the cathode, and the charge scaling of detrimental postinjector linac effects, e.g., transverse wakefields and CSR

  3. RF Photoelectric injectors using needle cathodes

    Science.gov (United States)

    Lewellen, J. W.; Brau, C. A.

    2003-07-01

    Photocathode RF guns, in various configurations, are the injectors of choice for both current and future applications requiring high-brightness electron beams. Many of these applications, such as single-pass free-electron lasers, require beams with high brilliance but not necessarily high charge per bunch. Field-enhanced photoelectric emission has demonstrated electron-beam current density as high as 10 10 A/m 2, with a quantum efficiency in the UV that approaches 10% at fields on the order of 10 10 V/m. Thus, the use of even a blunt needle holds promise for increasing cathode quantum efficiency without sacrificing robustness. We present an initial study on the use of needle cathodes in photoinjectors to enhance beam brightness while reducing beam charge. Benefits include lower drive-laser power requirements, easier multibunch operation, lower emittance, and lower beam degradation due to charge-dependent effects in the postinjector accelerator. These benefits result from a combination of a smaller cathode emission area, greatly enhanced RF field strength at the cathode, and the charge scaling of detrimental postinjector linac effects, e.g., transverse wakefields and CSR.

  4. Extramedullary plasmacytoma. Fine needle aspiration findings.

    Science.gov (United States)

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  5. Fine needle aspiration cytology of parapharyngeal tumors

    Directory of Open Access Journals (Sweden)

    Mondal Palash

    2009-01-01

    Full Text Available Background: Parapharyngeal tumors are rare and often pose diagnostic difficulties due to their location and plethora of presentations. Objectives: The study was undertaken to study the occurrence in the population and to evaluate the exact nature by fine needle aspiration cytology (FNAC. Materials and Methods: A total of five hundred and six cases of lateral neck lesions were studied over three and half years. Of these 56 suspected parapharyngeal masses were selected by clinical and radiological methods. Cytopathology evaluation was done by fine needle aspiration cytology with computed tomography and ultrasonography guidance wherever necessary. Histopathology confirmation was available in all the cases. Results: On FNAC diagnosis could be established in 54 cases while in two cases the material was insufficient to establish a diagnosis. The tumors encountered were, pleomorphic adenoma (33, schwannoma (3, neurofibroma (11, paraganglioma (5, angiofibroma (1 and adenoid cystic carcinoma (1. Four false positives and two false negative cases were encountered. Overall sensitivity was 96%, with specificity of 99% and accuracy being 98.8%. Conclusions: With proper clinical and radiological assessment, FNAC can be extremely useful in diagnosing most of these lesions except a few which need histopathological and even immunohistochemical confirmation.

  6. Investigations of needle-free jet injections.

    Science.gov (United States)

    Schramm-Baxter, J R; Mitragotri, S

    2004-01-01

    Jet injection is a needle-free drug delivery method in which a high-speed stream of fluid impacts the skin and delivers drugs. Although a number of jet injectors are commercially available, especially for insulin delivery, they have a low market share compared to needles possibly due to occasional pain associated with jet injection. Jets employed by the traditional jet injectors penetrate deep into the dermal and sub-dermal regions where the nerve endings are abundantly located. To eliminate the pain associated with jet injections, we propose to utilize microjets that penetrate only into the superficial region of the skin. However, the choice of appropriate jet parameters for this purpose is challenging owing to the multiplicity of factors that determine the penetration depth. Here, we describe the dependence of jet injections into human skin on the power of the jet. Dermal delivery of liquid jets was quantified using two measurements, penetration of a radiolabeled solute, mannitol, into skin and the shape of jet dispersion in the skin which was visualized using sulforhodamine B. The dependence of the amount of liquid delivered in the skin and the geometric measurements of jet dispersion on nozzle diameter and jet velocity was captured by a single parameter, jet power.

  7. Needle placement accuracy during stereotactic localization mammography

    International Nuclear Information System (INIS)

    Green, D.H.

    2009-01-01

    Aim: To derive a mathematical model to describe the relationship between lesion position in the breast and measurements derived from the stereoradiographs to enable more accurate sampling of a lesion during stereotactic mammographic needle placement. Materials and methods: The affect that registration errors have on the accuracy of needle placement when identifying the lesion on the stereoradiographs was investigated using the mathematical model. Results: The focus-to-film distance of the x-ray tube and the horizontal distance of the lesion from the centre of rotation have little effect on error. Registration errors for lesions lying at a greater perpendicular distance in the breast from the centre of rotation produce smaller localization errors when compared with lesions sited closer. Lesion registration errors during marking of the stereoradiographs are exacerbated by decreasing the angle of x-ray tube swing. Conclusions: When problems are encountered in making an accurate registration of the lesion on the stereoradiographs, consider the following error reducing strategies: (1) employ an approach that places the lesion the maximum distance away from the film cassette; (2) avoid reducing the angle of tube swing; and (3) consider sampling superficial and deep to, as well as at, the location indicated. The possibility of erroneous tissue sampling should be borne in mind when reviewing the pathology report.

  8. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  9. [Closed needle-biopsy in the diagnosis of neoplasms].

    Science.gov (United States)

    Sforza, M; Perelli Ercolini, M; Beani, G

    1979-04-01

    The AA. demonstrate with this communication the validity of the needle biopsie for the diagnosis of neoplasms. They had used it for the breast, thyroid, flg and some other superficial tumefactions. In the mass-screening for the feminine neoplasms the clinical examination and the needle biopsy are very good method for a careful diagnosis.

  10. Darning Needle Impacted in the Male Urethra | Singla | African ...

    African Journals Online (AJOL)

    Foreign bodies of varied nature have been introduced into the urethra to achieve sexual stimulation. We report the case of a long (9.5 cm) darning needle impacted in the urethra of a male patient following urethral masturbation. After a failed trial at endoscopic extraction the needle had to be removed via open surgery.

  11. Prevalence of Needle Stick Injuries among Healthcare Workers in ...

    African Journals Online (AJOL)

    Background: Needle stick injuries represent one of the most important occupational hazards to which health workers are exposed. These injuries result from accidental piercing of the skin and or mucous membranes by sharp objects. Needle stick injuries carry the risk of exposure to blood-borne pathogens, especially ...

  12. Effect of dietary mugwort ( Artemisia vulgaris L.) and pine needle ...

    African Journals Online (AJOL)

    The effects of dietary mugwort and pine needle powder supplementation on growth performance, serum cholesterol, and meat quality of broilers were evaluated in a 35 days feed trial. 200 one day old broilers were randomly allocated to five dietary treatments (0, 1 and 2% mugwort or 1 and 2% pine needle powder) with ...

  13. Improvements to the Processing and Characterization of Needled Composite Laminates

    Science.gov (United States)

    2014-01-01

    the automated processing equipment are shown and discussed. The modifications allow better spatial control at the penetration sites and the ability... automated processing equipment are shown and discussed. The modifications allow better spatial control at the penetration sites and the ability to...semi- automated processing equipment, commercial off-the-shelf (COTS) needles and COTS aramid mat designed for other applications. Needled material

  14. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  15. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  16. Needle-shaped and platelet growth of borax crystals

    International Nuclear Information System (INIS)

    Takoo, R.K.; Patel, B.R.; Joshi, M.S.

    1983-01-01

    Needle-shaped and platelet growth of borax crystals from solutions is reported. Results of microtopographical studies on both the varieties are discussed. It is suggested that a slow rate of evaporation favours needle growth and a faster rate is conducive to the growth of platelets. (author)

  17. Spinal anaesthesia in young patients: evaluation of needle gauge ...

    African Journals Online (AJOL)

    Background:The well-known complication of spinal anaesthesia, postdural puncture headache (PDPH), is especially troublesome in young patients. The needle gauge and configuration of needle tip appear to be the important factors in reducing the incidence of PDPH; however it may increase the incidence of technical ...

  18. Observations on rotating needle insertions using a brachytherapy robot

    International Nuclear Information System (INIS)

    Meltsner, M A; Ferrier, N J; Thomadsen, B R

    2007-01-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy

  19. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  20. Laser-Controlled Growth of Needle-Shaped Organic Nanoaggregates

    DEFF Research Database (Denmark)

    Balzer, Frank; Rubahn, Horst-Günter

    2002-01-01

    Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometer....... While the orientation of the individual molecules in the needles is defined by the direction of surface dipoles, the localization on the surface, the length distribution as well as mutual distances can be adjusted via size and position of the laser focus spot.......Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometers...

  1. NEEDLE KNIFE SPHINCTEROTOMY - THE CHRIS HANI BARAGWANATH ACADEMIC HOSPITAL EXPERIENCE.

    Science.gov (United States)

    Thomson, J T; Smith, M D; Omoshoro-Jones, J A O; Devar, J D; Khan, Z K; Jugmohan, B J

    2017-06-01

    Deep biliary cannulation is essential in performing a therapeutic ERCP. Cannulation can be enhanced through the utilization of a pre-cut by means of a needle knife sphincterotomy. Retrospective analysis of the Chris Hani Baragwanath Academic Hospital's ERCP database was performed. All ERCPs performed with the aid of a needle knife were identified and analysed for successful and unsuccessful deep biliary cannulation. 2830 ERCPs were performed during the study period. 369 (13%) required needle knife sphincterotomies and successful deep biliary cannulation was achieved in 229 (62%) of these patients. Repeat ERCPs were performed on 125 (34%) patients. 61 (49%) of the repeat ERCPs were performed because of previously failed cannulation. 34 (56%) of these repeat ERCPs resulted in successful deep biliary cannulation at re-attempt. 99% of successful cannulations at repeat ERCP had had a needle knife sphincterotomy at the first ERCP. Needle knife sphincterotomy improves deep biliary cannulation at initial ERCP and subsequent ERCPs with low incidences of complications.

  2. CUDA accelerated simulation of needle insertions in deformable tissue

    International Nuclear Information System (INIS)

    Patriciu, Alexandru

    2012-01-01

    This paper presents a stiff needle-deformable tissue interaction model. The model uses a mesh-less discretization of continuum; avoiding thus the expensive remeshing required by the finite element models. The proposed model can accommodate both linear and nonlinear material characteristics. The needle-deformable tissue interaction is modeled through fundamental boundaries. The forces applied by the needle on the tissue are divided in tangent forces and constraint forces. The constraint forces are adaptively computed such that the material is properly constrained by the needle. The implementation is accelerated using NVidia CUDA. We present detailed analysis of the execution timing in both serial and parallel case. The proposed needle insertion model was integrated in a custom software that loads DICOM images, generate the deformable model, and can simulate different insertion strategies.

  3. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  4. Vitamin K antagonist use and mortality in dialysis patients

    NARCIS (Netherlands)

    Voskamp, Pauline W.M.; Rookmaaker, Maarten B.; Verhaar, Marianne C.; Dekker, Friedo W.; Ocak, Gurbey

    2018-01-01

    Background. The risk-benefit ratio of vitamin K antagonists for different CHA2DS2-VASc scores in patients with end-stage renal disease treated with dialysis is unknown. The aim of this study was to investigate the association between vitamin K antagonist use and mortality for different CHA2DS2-VASc

  5. High fall incidence and fracture rate in elderly dialysis patients

    NARCIS (Netherlands)

    Polinder-Bos, H. A.; Emmelot-Vonk, M. H.; Gansevoort, R. T.; Diepenbroek, A.; Gaillard, C. A. J. M.

    2014-01-01

    Background: Although it is recognised that the dialysis population is ageing rapidly, geriatric complications such as falls are poorly appreciated, despite the many risk factors for falls in this population. The objective of this study was to determine the incidence, complications and risk factors

  6. Peritoneal dialysis in an ageing population: a 10-year experience.

    LENUS (Irish Health Repository)

    Smyth, Andrew

    2012-02-01

    Chronic kidney disease (CKD) is becoming increasingly prevalent and there are increasing numbers of older patients with advanced CKD. Peritoneal dialysis (PD) is a potential treatment. This study aims to compare PD outcomes in age-defined populations in the largest PD centre in the Republic of Ireland over 10 years.

  7. Detection of microorganisms, endotoxins and aluminum in mobile dialysis services

    Directory of Open Access Journals (Sweden)

    Priscila Rodrigues de Jesus

    2017-11-01

    Full Text Available Hemodialysis water and dialysates are fundamental in the treatment of kidney disease. During just one hemodialysis session, 120 liters of dialysate are consumed. Thus, it is essential that the parameters of chemical and microbiological quality of the fluids used in dialysis systems are carefully observed. In this study, water samples were collected at 12 hospitals in the state of Rio de Janeiro. The samples were obtained at three points of fluid reservoirs: pre-, post-osmosis and dialysis solution. After collection, colony forming units (CFU, total coliforms and Escherichia coli 100 mL-1 were quantified. Later, isolated colonies and endotoxin content were identified by biochemical assays. Data about total aluminum levels per sample (mg L-1 were also obtained. Samples of all mobile dialysis services and points of collection were contaminated above the levels set out by national laws, in particular by Pseudomonas aeruginosa. Endotoxin levels were also above the recommended by current legislation (> 0.25 EU mL-1. Only three samples contained detectable levels of aluminum, which were found to be above the recommended values for the corresponding resolution (0.01 mg L-1. Finally, there were no observable amounts of total coliforms and E. coli 100 mL-1 sample. The data from this study are an important step forward in the standardization and control of chemical/microbiological quality of mobile dialysis services.

  8. Benfotiamine protects against peritoneal and kidney damage in peritoneal dialysis.

    Science.gov (United States)

    Kihm, Lars P; Müller-Krebs, Sandra; Klein, Julia; Ehrlich, Gregory; Mertes, Laura; Gross, Marie-Luise; Adaikalakoteswari, Antonysunil; Thornalley, Paul J; Hammes, Hans-Peter; Nawroth, Peter P; Zeier, Martin; Schwenger, Vedat

    2011-05-01

    Residual renal function and the integrity of the peritoneal membrane contribute to morbidity and mortality among patients treated with peritoneal dialysis. Glucose and its degradation products likely contribute to the deterioration of the remnant kidney and damage to the peritoneum. Benfotiamine decreases glucose-induced tissue damage, suggesting the potential for benefit in peritoneal dialysis. Here, in a model of peritoneal dialysis in uremic rats, treatment with benfotiamine decreased peritoneal fibrosis, markers of inflammation, and neovascularization, resulting in improved characteristics of peritoneal transport. Furthermore, rats treated with benfotiamine exhibited lower expression of advanced glycation endproducts and their receptor in the peritoneum and the kidney, reduced glomerular and tubulointerstitial damage, and less albuminuria. Increased activity of transketolase in tissue and blood contributed to the protective effects of benfotiamine. In primary human peritoneal mesothelial cells, the addition of benfotiamine led to enhanced transketolase activity and decreased expression of advanced glycation endproducts and their receptor. Taken together, these data suggest that benfotiamine protects the peritoneal membrane and remnant kidney in a rat model of peritoneal dialysis and uremia. Copyright © 2011 by the American Society of Nephrology

  9. [Optimal use of peritoneal dialysis with multi-disciplinary management].

    Science.gov (United States)

    Elios Russo, Gaspare; Martinez, A; Mazzaferro, S; Nunzi, A; Testorio, M; Rocca, A R; Lai, S; Morgia, A; Borzacca, B; Gnerre Musto, T

    2013-01-01

    Considering the increasing incidence of chronic kidney disease and the increased use of peritoneal dialysis, we wanted to assess whether the multidisciplinary management of patients in peritoneal dialysis might produce improvement in the quality of patients' lives when compared to management by a routine team of operators. Our study observed 40 patients on peritoneal dialysis in our Department between 2010 and 2012. They were randomly assigned to either group A, the routine team which consisted of a nephrologist and a nurse, or group B, a multidisciplinary team comprising several medical specialists, a nurse, a psychologist and a social worker. Two tests, KDQOL-SF and MMPI-2, were administered to both groups. In group B, the number of days of hospitalization and day hospital were more than 88% lower when compared to group A. The multidisciplinary team achieved better results with the KDQOL-SF test with regards to both emotional and objective dimensions. The Pearson coefficient between the results of the two questionnaires shows how multidisciplinary management can positively influence the perceived well-being of the patient and his or her adherence to treatment. In a multidisciplinary team, each operator, in addition to his or her specific role, also contributes to the achievement of the overall objective, namely of ensuring an optimal quality of life to the patient on peritoneal dialysis thereby allowing these patients to continue their professional and social lives.

  10. Relative survival of peritoneal dialysis and haemodialysis patients

    DEFF Research Database (Denmark)

    Heaf, James G; Wehberg, Sonja

    2014-01-01

    INTRODUCTION: Epidemiological studies consistently show an initial survival advantage for PD patients compared to HD. It has recently been suggested that this is due to the fact that many HD patients are referred late, and start dialysis on an acute, in-patient basis. The present study was perfor...

  11. Capnocytophaga cynodegmi peritonitis in a peritoneal dialysis patient

    DEFF Research Database (Denmark)

    Pers, Charlotte; Tvedegaard, Erling; Christensen, Jens Jørgen

    2007-01-01

    The first reported case of peritonitis caused by Capnocytophaga cynodegmi is presented. The patient was treated with peritoneal dialysis and had contact with a cat. C. cynodegmi is part of the normal oral flora of dogs and cats but is very rarely isolated in clinical specimens from humans....

  12. Peritoneal Dialysis-Related Peritonitis: Atypical and Resistant Organisms

    NARCIS (Netherlands)

    Cho, Yeoungjee; Struijk, Dirk Gijsbert

    2017-01-01

    Peritoneal dialysis (PD)-related peritonitis remains to be one of the most frequent and serious complications of PD. In this study, existing literature has been reviewed on PD peritonitis caused by atypical organisms and antibiotic resistant organisms and their impact on patient outcomes. Although

  13. Quantification of free water transport in peritoneal dialysis

    NARCIS (Netherlands)

    Smit, Watske; Struijk, Dirk G.; Ho-Dac-Pannekeet, Marja M.; Krediet, Raymond T.

    2004-01-01

    BACKGROUND: In peritoneal dialysis (PD) total net ultrafiltration (NUF) is dependent on transport through small pores and through water channels in the peritoneum. These channels are impermeable to solutes, and therefore, crystalloid osmotic-induced free water transport occurs through them. Several

  14. Advances in peritoneal dialysis: towards improved efficacy and safety

    NARCIS (Netherlands)

    Krediet, R. T.

    1998-01-01

    BACKGROUND: The success of peritoneal dialysis on the short-term is mainly dependent on the prevention of infectious and technical complications. The mid-term results will to a large extent be determined by the ability to remove enough uraemic toxins to prevent uraemic complications and

  15. [Technological advances and micro-inflammation in dialysis patients].

    Science.gov (United States)

    Ferro, Giuseppe; Ravaglia, Fiammetta; Ferrari, Elisa; Romoli, Elena; Michelassi, Stefano; Caiani, David; Pizzarelli, Francesco

    2015-01-01

    As currently performed, on line hemodiafiltration reduces, but does not normalize, the micro-inflammation of uremic patients. Recent technological advances make it possible to further reduce the inflammation connected to the dialysis treatment. 
Short bacterial DNA fragments are pro-inflammatory and can be detected in the dialysis fluids. However, their determination is not currently within normal controls of the quality of the dialysate. The scenario may change once the analysis of these fragments yields reliable, inexpensive, quick and easy to evaluate the results. At variance with standard bicarbonate dialysate, Citrate dialysate induces far less inflammation both for the well-known anti-inflammatory effect of such buffer and also because it is completely acetate free, e.g. a definitely pro-inflammatory buffer. However, the extensive use of citrate dialysate in chronic dialysis is prevented because of concerns about its potential calcium lowering effect. In our view, high convective exchange on line hemodiafiltration performed with dialysate, whose sterility and a-pirogenicity is guaranteed by increasingly sophisticated controls and with citrate buffer whose safety is certified, can serve as the gold standard of dialysis treatments in future.

  16. [Patients' opinions and expectations about the dialysis care process].

    Science.gov (United States)

    Prieto, M A; Escudero, M J; Suess, A; March, J C; Ruiz, A; Danet, A

    2011-01-01

    To determine the experiences and needs of patients on dialysis, in order to identify critical points of the care process and develop proposals for improvement. Qualitative study using semistructured interviews with 22 patients on hemodialysis and peritoneal dialysis, from the Andalusian Health Service. Discourse analysis, using the SERVQUAL model. Triangulation of results. The diagnostic stage is described as the hardest moment as it requires acceptance of the disease. During hemodialysis, we see both positive adaptation and the perception of a diminished quality of life. The technique of peritoneal dialysis is evaluated positively, enabling greater independence, despite requiring more responsibility for self care. The contact with patients' organizations or the provision of a counseling service are valued as an aid in the process. With respect to different dimensions of the SERVQUAL model, human treatment and professional competence are valued. The critical points are lack of coordination, malfunctioning of transportation and lack of transparency in the management of waiting lists. Shortcomings in dealing with informal caregivers and the level of knowledge of professionals from areas other than Nephrology, also appear as deficiencies. The main proposals for improving the dialysis process are: attention to psychosocial aspects, the improvement of organizational aspects such as transport, and greater attention to informal caregivers.

  17. [Automatic system control and its application in dialysis].

    Science.gov (United States)

    Santoro, A; Mancini, E; Ferramosca, E

    2007-01-01

    The progressive increase in the mean age of dialysis patients associated with increasing comorbidity factors such as the presence of cardiovascular disease and diabetes have significantly worsened patients' clinical status and tolerance to hemodialysis. On the other hand, the demand for short treatment times increases the risk of hemodynamic instability as well as inadequate depuration. The traditional management of the dialysis session by setting predefined treatment parameters and carrying out active therapeutic intervention only in the event of complications is definitely unsuitable for short-lasting treatments, which are often complicated by hemodynamic instability, especially in critically ill patients. The first step in improving the management of the dialysis session is the use of uninvasive systems for continuous monitoring of the hemodynamic and biochemical parameters that characterize dialysis quality. In the last decade, special sensors have been designed for continuous measurement of blood volume, blood temperature, blood pressure, heart rate and electrolytes. As a second step, some of these devices have been interfaced with the dialysis equipment, mainly with a view to preventing cardiocirculatory instability but also monitoring the efficiency of dialysis (biofeedback control systems). The basic components of a biofeedback system are the plant, the sensors, the actuators, and the controller. The plant is the biological process we need to control, while the sensors are the devices used for measuring the output variables. The actuators are the working arms of the controller. The controller is the mathematical model that continuously sets the measured output variable against the reference input and modifies the actuators in order to reduce any discrepancies. In actual practice, however, there are a number of conceptual, physical and technological difficulties to overcome. In particular, the behavior of what is to be controlled may be nonlinear and time

  18. Multicentre study of treatment outcomes in Australian adolescents and young adults commencing dialysis.

    Science.gov (United States)

    Krischock, Leah; Kennedy, Sean E; Hayen, Andrew

    2017-12-01

    The aim of the study is to improve the understanding of outcomes and complications of dialysis in adolescents and young adults (AYA) to inform decisions about dialysis modality in this patient population. Registry data on Australian AYA aged 13 to 20 years who commenced dialysis between 1/1/2000 and 31/12/2013 were retrieved from the Australia and New Zealand Dialysis and Transplantation Registry and analyzed to determine associations between demographic characteristics, dialysis modality and outcomes. During the study period 300 AYA commenced dialysis at a median age of 17.2 years (IQR 15.6 to 18.6 years). Haemodialysis (HD) was the initial dialysis modality in 201 patients (67%). No significant differences between AYA receiving HD and peritoneal dialysis (PD) were noted in patient gender, age, race, primary renal disease, treating centre type, remoteness of residential area, lateness of referral or period of study. Mean haemoglobin levels were lower in the HD group (P = 0.005) and significantly fewer HD patients attended school full time compared to patients managed on PD (P = 0.002 first year; P = 0.05 second year). Dialysis modality choice does not appear to be influenced by patient characteristics nor dialysis outcomes. Future research is required to examine the reasons that HD is preferred over PD and to determine the optimal method of dialysis for this age group. © 2016 Asian Pacific Society of Nephrology.

  19. Effect of bidirectional rotation of an acupuncture needle at LI10 on acupuncture needle sensation and experimentally-induced contact heat pain in healthy human volunteers.

    Science.gov (United States)

    Benham, Alex; Johnson, Mark I

    2014-06-01

    There is insufficient evidence of a relationship between acupuncture needle sensations (de qi) and hypoalgesia. The aim of this study was to investigate the effects of bidirectional needle rotation at LI10 on acupuncture needle sensations and heat pain thresholds. Twenty-two healthy participants received one acupuncture needle at LI10 with bidirectional rotation of the needle in one experimental session and one acupuncture needle at LI10 with mock rotation in a separate session, in a randomised order. Measurements of heat pain thresholds were taken before needle insertion, during needle retention and 15 min after needle removal. At each measurement time point, participants rated needle sensations using the Massachusetts Acupuncture Sensation Scale (MASS) and a visual analogue scale (VAS) of overall intensity of needle sensation. Bidirectional needle rotation produced significantly higher scores for VAS, MASStotal, MASSpain and MASSsensation compared with mock rotation (all psensation and change in pain threshold after needling was only found when data from mock and rotation interventions were combined. Needle rotation increases the magnitude of hypoalgesia. There is tentative evidence that needle sensation may be associated with the amount of change in pain threshold. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Comparative cyto-histological study of needle tip aspirates and entry sites after intravitreal injection using different needle types.

    Directory of Open Access Journals (Sweden)

    Lyubomyr Lytvynchuk

    Full Text Available A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements.

  1. Polymer blends

    Energy Technology Data Exchange (ETDEWEB)

    Allen, Scott D.; Naik, Sanjeev

    2017-08-22

    The present invention provides, among other things, extruded blends of aliphatic polycarbonates and polyolefins. In one aspect, provided blends comprise aliphatic polycarbonates such as poly(propylene carbonate) and a lesser amount of a crystalline or semicrystalline polymer. In certain embodiments, provided blends are characterized in that they exhibit unexpected improvements in their elongation properties. In another aspect, the invention provides methods of making such materials and applications of the materials in applications such as the manufacture of consumer packaging materials.

  2. [Acupuncture therapy for regaining consciousness in terms of acupoint location, needle insertion and needle manipulation].

    Science.gov (United States)

    Meng, Xianggang; Gu, Wenlong; Ma, Fen; Du, Yuzheng; Zhao, Qi

    2015-03-01

    Acupuncture therapy for regaining consciousness activates soreness, numbness, distention, heaviness, radiating and moving, electric shock and ant climbing sensations at the specific acupoints in the stroke patients. Radiating and moving sensations are the summary of needling sensations such as soreness, numbness and twitching presenting during lifting and thrusting manipulation. These sensations are the essential factors of the therapeutic effect of regaining consciousness. Radiating sensation refers to the conduction along meridians and radiation of soreness and numbness. Moving sensation refers to the local muscular twitching at acupoints and the involuntary movement of limbs, joints and the distal. Acupuncture at the specific acupoints achieves radiating and moving sensations for promoting the circulation in meridians, regulating qi and mind and balancing yin and yang in stroke patients. This therapy was introduced in the paper in view of acupoint location, needle insertion and manipulation.

  3. Vasoactive Peptide Levels after Change of Dialysis Mode

    Directory of Open Access Journals (Sweden)

    Fredrik Uhlin

    2015-10-01

    Full Text Available Background/Aims: Plasma concentrations of the N-terminal fragment of pro-brain natriuretic peptide (NT-proBNP are increased in end-stage renal disease. Improvement in hemodynamic stability has been reported when switching from hemodialysis (HD to on-line hemodiafiltration (ol-HDF. The aim of this study was to investigate plasma concentrations of NT-proBNP, BNP and neuropeptide Y (NPY during a 1-year follow-up, after a change from high-flux HD to postdilution ol-HDF. Additional variables were also studied, e.g. pulse wave velocity and ordinary clinical parameters. Method: We conducted a prospective, single-center study including 35 patients who were switched from HD to HDF. Plasma concentrations of NT-proBNP, BNP and NPY before and after dialysis were measured at baseline (i.e. HD and at 1, 2, 4, 6 and 12 months on HDF. Results: All three peptide levels decreased significantly during HD and HDF when comparing concentrations before and after dialysis. Mean absolute value (before/after and relative decrease (% before versus after dialysis was 13.697/9.497 ng/l (31% for NT-proBNP, 62/40 ng/ml (35% for BNP and 664/364 pg/l (45% for NPY. No significant differences were observed when comparing predialysis values over time. However, postdialysis NT-proBNP concentration showed a significant decrease of 48% over time after the switch to HDF. Conclusion: The postdialysis plasma levels of NT-proBNP, BNP and NPY decreased significantly during both dialysis modes when compared to before dialysis. The postdialysis lowering of NT-proBNP increased further over time after the switch to ol-HDF; the predialysis levels were unchanged, suggesting no effect on its production in the ventricles of the heart.

  4. Burnout Syndrome Among Hemodialysis and Peritoneal Dialysis Nurses.

    Science.gov (United States)

    Karakoc, Ayten; Yilmaz, Murvet; Alcalar, Nilufer; Esen, Bennur; Kayabasi, Hasan; Sit, Dede

    2016-11-01

    Burnout, a syndrome with 3 dimensions of emotional exhaustion, depersonalization, and reduction of personal accomplishment, is very common among hemodialysis nurses, while data are scarce regarding the prevalence of burnout syndrome (BS) among peritoneal dialysis (PD) nurses. This study aimed to assess and compare demographic and professional characteristics and burnout levels in hemodialysis and PD nurses, and to investigate factors that increase the level of burnout in dialysis nurses. A total of 171 nurses from 44 dialysis centers in Turkey were included in a cross-sectional survey study. Data were collected using a questionnaire defining the social and demographic characteristics and working conditions of the nurses as well as the Maslach Burnout Inventory for assessment of burnout level. There was no significant difference in the level of burnout between the hemodialysis and PD nurses groups. Emotional exhaustion and depersonalization scores were higher among the shift workers, nurses who had problems in interactions with the other team members, and those who wanted to leave the unit, as well as the nurses who would not attend training programs. In addition, male sex, younger age, limited working experience, more than 50 hours of working per week, and working in dialysis not by choice were associated with higher depersonalization scores. Personal accomplishment score was lower among the younger nurses who had problems in their interactions with the doctors, who would not regularly attend training programs, and who felt being medically inadequate. Improving working conditions and relations among colleagues, and also providing further dialysis education are necessary for minimizing burnout syndrome. Burnout reduction programs should mainly focus on younger professionals.

  5. Depression in hemodialysis patients: the role of dialysis shift

    Directory of Open Access Journals (Sweden)

    Flavio Teles

    2014-03-01

    Full Text Available OBJECTIVE: Depression is the most important neuropsychiatric complication in chronic kidney disease because it reduces quality of life and increases mortality. Evidence demonstrating the association between dialysis shift and depression is lacking; thus, obtaining such evidence was the main objective of this study. METHOD: This cross-sectional study included patients attending a hemodialysis program. Depression was diagnosed using Beck's Depression Inventory. Excessive daytime sleepiness was evaluated using the Epworth Sleepiness Scale. RESULTS: A total of 96 patients were enrolled (55 males, age 48±14 years. Depression and excessive daytime sleepiness were observed in 42.7% and 49% of the patients, respectively. When comparing variables among the three dialysis shifts, there were no differences in age, dialysis vintage, employment status, excessive daytime sleepiness, hemoglobin, phosphorus levels, or albumin levels. Patients in the morning shift were more likely to live in rural areas (p<0.0001, although patients in rural areas did not have a higher prevalence of depression (p= 0.30. Patients with depression were more likely to be dialyzed during the morning shift (p= 0.008. Independent risk factors for depression were age (p<0.03, lower levels of hemoglobin (p<0.01 and phosphorus (p<0.01, and dialysis during the morning shift (p= 0.0009. The hospitalization risk of depressive patients was 4.5 times higher than that of nondepressive patients (p<0.008. CONCLUSION: These data suggest that depression is associated with dialysis shift, higher levels of phosphorus, and lower levels of hemoglobin. The results highlight the need for randomized trials to determine whether this association occurs by chance or whether circadian rhythm disorders may play a role.

  6. Rationale for a home dialysis virtual ward: design and implementation.

    Science.gov (United States)

    Schachter, Michael E; Bargman, Joanne M; Copland, Michael; Hladunewich, Michelle; Tennankore, Karthik K; Levin, Adeera; Oliver, Matthew; Pauly, Robert P; Perl, Jeffrey; Zimmerman, Deborah; Chan, Christopher T

    2014-02-14

    Home-based renal replacement therapy (RRT) [peritoneal dialysis (PD) and home hemodialysis (HHD)] offers independent quality of life and clinical advantages compared to conventional in-center hemodialysis. However, follow-up may be less complete for home dialysis patients following a change in care settings such as post hospitalization. We aim to implement a Home Dialysis Virtual Ward (HDVW) strategy, which is targeted to minimize gaps of care. The HDVW Pilot Study will enroll consecutive PD and HHD patients who fulfilled any one of our inclusion criteria: 1. following discharge from hospital, 2. after interventional procedure(s), 3. prescription of anti-microbial agents, or 4. following completion of home dialysis training. Clinician-led telephone interviews are performed weekly for 2 weeks until VW discharge. Case-mix (modified Charlson Comorbidity Index), symptoms (the modified Edmonton Symptom Assessment Scale) and patient satisfaction are assessed serially. The number of VW interventions relating to eight pre-specified domains will be measured. Adverse events such as re-hospitalization and health-services utilization will be ascertained through telephone follow-up after discharge from the VW at 2, 4, 12 weeks. The VW re-hospitalization rate will be compared with a contemporary cohort (matched for age, gender, renal replacement therapy and co-morbidities). Our protocol has been approved by research ethics board (UHN: 12-5397-AE). Written informed consent for participation in the study will be obtained from participants. This report serves as a blueprint for the design and implementation of a novel health service delivery model for home dialysis patients. The major goal of the HDVW initiative is to provide appropriate and effective supports to medically complex patients in a targeted window of vulnerability. (NCT01912001).

  7. BODY COMPOSITION IN HEMODIALYSIS AND PERITONEAL DIALYSIS PATIENTS

    Directory of Open Access Journals (Sweden)

    Nam Ho Kim

    2012-06-01

    Full Text Available Bioimpedance analysis is a reliable technique for determining post dialysis target weight. Using this technique, we can understand body fluid status easier and conveniently. Moreover this technique can be used for check nutrition status and nutritional status of dialysis patients. We compared the body fluid status and nutrition status between hemodialysis (HD patients and peritoneal dialysis (PD patients by BCM (Body composition monitor technique. We studied 48 (30 males and 18 females PD patients, 21 (10 males and 11 females HD patients. Body composition monitoring (BCM, Fesenitus Medical Care, Germany was used as a tool for the analysis of bioimpedance. Extracellular water, Total body water, Intracellular water, Overhydration, E/I, Lean tissue mass, Fat Tissue mass was measured and those results were compared between two groups. HD patients were more hydrated than PD patients (61.9% vs. 35.4% and nutritional status such as LTI was poorer than peritoneal dialysis patients (11.7±1.7 vs. 15.3±2.6. Although total body water is more abundant in peritoneal patients (29.4±5.5L vs. 35.9±6.2L, Extracellular water and intracellular water ratio was relatively higher in Hemodialysis patients (E/I 0.98±0.13 vs. 0.87±0.12. The nutrition status was better in PD patients by comparing the percent of lean tissue mass (LTM% between two groups (LTM% 52.1±10.6% vs. 66.8±11.3. In conclusions, Hemodialysis patients were more hydrated with poorer nutrition status than peritoneal dialysis patients, but, due to the significant difference of age between two groups, further study should be required.

  8. Shikimate dehydrogenase from Pinu sylvestris L. needles

    International Nuclear Information System (INIS)

    Osipov, V.I.; Shein, I.V.

    1986-01-01

    Shikimate dehydrogenase was isolated by extraction from pine needles and partially purified by fractionation with ammonium sulfate. In conifers, in contrast to other plants, all three isoenzymes of shikimate dehydrogenase exhibit activity not only with NADP + , but also with NAD + . The values of K/sub m/ for shikimate, when NADP + and NAD + are used as cofactors, are 0.22 and 1.13 mM, respectively. The enzyme is maximally active at pH 10 with both cofactors. It is suggested that NAD-dependent shikimate dehydrogenase catalyzes the initial reaction of the alternative pathway of the conversion of shikimic acid to hydroxybenzoic acid. The peculiarities of the organization and regulation of the initial reactions of the shikimate pathway in conifers and in plants with shikimate dehydrogenase absolutely specific for NADP are discussed

  9. Standard on microbiological management of fluids for hemodialysis and related therapies by the Japanese Society for Dialysis Therapy 2008.

    Science.gov (United States)

    Kawanishi, Hideki; Akiba, Takashi; Masakane, Ikuto; Tomo, Tadashi; Mineshima, Michio; Kawasaki, Tadayuki; Hirakata, Hideki; Akizawa, Tadao

    2009-04-01

    The Committee of Scientific Academy of the Japanese Society for Dialysis Therapy (JSDT) proposes a new standard on microbiological management of fluids for hemodialysis and related therapies. This standard is within the scope of the International Organization for Standardization (ISO), which is currently under revision. This standard is to be applied to the central dialysis fluid delivery systems (CDDS), which are widely used in Japan. In this standard, microbiological qualities for dialysis water and dialysis fluids are clearly defined by endotoxin level and bacterial count. The qualities of dialysis fluids were classified into three levels: standard, ultrapure, and online prepared substitution fluid. In addition, the therapeutic application of each dialysis fluid is clarified. Since high-performance dialyzers are frequently used in Japan, the standard recommends that ultrapure dialysis fluid be used for all dialysis modalities at all dialysis facilities. It also recommends that the dialysis equipment safety management committee at each facility should validate the microbiological qualities of online prepared substitution fluid.

  10. Measured glomerular filtration rate at dialysis initiation and clinical outcomes of Indian peritoneal dialysis patients

    Directory of Open Access Journals (Sweden)

    N Prasad

    2017-01-01

    Full Text Available The optimal time for dialysis initiation remains controversial. Studies have failed to show better outcomes with early initiation of hemodialysis; even a few had shown increased adverse outcomes including poorer survival. Few studies have examined the same in patients on peritoneal dialysis (PD. Measured glomerular filtration rate (mGFR not creatinine-based estimated GFR is recommended as the measure of kidney function in end-stage renal disease (ESRD patients. The objective of this observational study was to compare the outcomes of Indian patients initiated on PD with different residual renal function (RRF as measured by 24-h urinary clearance method. A total of 352 incident patients starting on chronic ambulatory PD as the first modality of renal replacement therapy were followed prospectively. Patients were categorized into three groups as per mGFR at the initiation of PD (≤5, >5–10, and> 10 ml/min/1.73 m2. Patient survival and technique survival were compared among the three groups. Patients with GFR of ≤5 ml/min/1.73 m2 (hazard ratio [HR] - 3.42, 95% confidence interval [CI] - 1.85–6.30, P = 0.000 and> 5–10 ml/min/1.73 m2 (HR - 2.16, 95% CI - 1.26–3.71, P = 0.005 had higher risk of mortality as compared to those with GFR of> 10 ml/min/1.73 m2. Each increment of 1 ml/min/1.73 m2 in baseline GFR was associated with 10% reduced risk of death (HR - 0.90, 95% CI - 0.85–0.96, P = 0.002. Technique survival was poor in those with an initial mGFR of ≤5 ml/min/1.73 m2 as compared to other categories. RRF at the initiation was also an important factor predicting nutritional status at 1 year of follow-up. To conclude, initiation of PD at a lower baseline mGFR is associated with poorer patient and technique survival in Indian ESRD patients.

  11. Emergency percutaneous needle decompression for tension pneumoperitoneum

    Directory of Open Access Journals (Sweden)

    Körner Markus

    2011-05-01

    Full Text Available Abstract Background Tension pneumoperitoneum as a complication of iatrogenic bowel perforation during endoscopy is a dramatic condition in which intraperitoneal air under pressure causes hemodynamic and ventilatory compromise. Like tension pneumothorax, urgent intervention is required. Immediate surgical decompression though is not always possible due to the limitations of the preclinical management and sometimes to capacity constraints of medical staff and equipment in the clinic. Methods This is a retrospective analysis of cases of pneumoperitoneum and tension pneumoperitoneum due to iatrogenic bowel perforation. All patients admitted to our surgical department between January 2005 and October 2010 were included. Tension pneumoperitoneum was diagnosed in those patients presenting signs of hemodynamic and ventilatory compromise in addition to abdominal distension. Results Between January 2005 and October 2010 eleven patients with iatrogenic bowel perforation were admitted to our surgical department. The mean time between perforation and admission was 36 ± 14 hrs (range 30 min - 130 hrs, between ER admission and begin of the operation 3 hrs and 15 min ± 47 min (range 60 min - 9 hrs. Three out of eleven patients had clinical signs of tension pneumoperitoneum. In those patients emergency percutaneous needle decompression was performed with a 16G venous catheter. This improved significantly the patients' condition (stabilization of vital signs, reducing jugular vein congestion, bridging the time to the start of the operation. Conclusions Hemodynamical and respiratory compromise in addition to abdominal distension shortly after endoscopy are strongly suggestive of tension pneumoperitoneum due to iatrogenic bowel perforation. This is a rare but life threatening condition and it can be managed in a preclinical and clinical setting with emergency percutaneous needle decompression like tension pneumothorax. Emergency percutaneous decompression is no

  12. Is Peritonitis Risk Increased in Elderly Patients on Peritoneal Dialysis? Report from the French Language Peritoneal Dialysis Registry (RDPLF).

    Science.gov (United States)

    Duquennoy, Simon; Béchade, Clémence; Verger, Christian; Ficheux, Maxence; Ryckelynck, Jean-Philippe; Lobbedez, Thierry

    2016-01-01

    ♦ This study was carried out to examine whether or not elderly patients on peritoneal dialysis (PD) had an increased risk of peritonitis. ♦ This was a retrospective cohort study based on data from the French Language Peritoneal Dialysis Registry. We analyzed 8,396 incident patients starting PD between January 2003 and December 2010. The end of the observation period was 31 December 2012. Patients were separated into 2 age groups: up to 75 and over of 75 years old. ♦ Among 8,396 patients starting dialysis there were 3,173 patients older than 75. When using a Cox model, no association was found between age greater than 75 years and increased risk of peritonitis (hazard ratio [HR]: 0.97 [0.88 - 1.07]). Diabetes (HR: 1.14 [1.01 - 1.28] and continuous ambulatory PD (HR: 1.13 [1.04 - 1.23]) were significantly associated with a higher risk of peritoneal infection whereas nurse-assisted PD was associated with a lower risk of peritonitis (HR: 0.85 [0.78 - 0.94]. In the analysis restricted to the 3,840 self-care PD patients, there was no association between age older than 75 years and risk of peritonitis. ♦ The risk of peritonitis is not increased in elderly patients on PD in a country where assisted PD is available. Copyright © 2016 International Society for Peritoneal Dialysis.

  13. Factors influencing access to education, decision making, and receipt of preferred dialysis modality in unplanned dialysis start patients.

    Science.gov (United States)

    Machowska, Anna; Alscher, Mark Dominik; Reddy Vanga, Satyanarayana; Koch, Michael; Aarup, Michael; Qureshi, Abdul Rashid; Lindholm, Bengt; Rutherford, Peter A

    2016-01-01

    Unplanned dialysis start (UPS) leads to worse clinical outcomes than planned start, and only a minority of patients ever receive education on this topic and are able to make a modality choice, particularly for home dialysis. This study aimed to determine the predictive factors for patients receiving education, making a decision, and receiving their preferred modality choice in UPS patients following a UPS educational program (UPS-EP). The Offering Patients Therapy Options in Unplanned Start (OPTiONS) study examined the impact of the implementation of a specific UPS-EP, including decision support tools and pathway improvement on dialysis modality choice. Linear regression models were used to examine the factors predicting three key steps: referral and receipt of UPS-EP, modality decision making, and actual delivery of preferred modality choice. A simple economic assessment was performed to examine the potential benefit of implementing UPS-EP in terms of dialysis costs. The majority of UPS patients could receive UPS-EP (214/270 patients) and were able to make a decision (177/214), although not all patients received their preferred choice (159/177). Regression analysis demonstrated that the initial dialysis modality was a predictive factor for referral and receipt of UPS-EP and modality decision making. In contrast, age was a predictor for referral and receipt of UPS-EP only, and comorbidity was not a predictor for any step, except for myocardial infarction, which was a weak predictor for lower likelihood of receiving preferred modality. Country practices predicted UPS-EP receipt and decision making. Economic analysis demonstrated the potential benefit of UPS-EP implementation because dialysis modality costs were associated with modality distribution driven by patient preference. Education and decision support can allow UPS patients to understand their options and choose dialysis modality, and attention needs to be focused on ensuring equity of access to educational

  14. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  15. Return Rates for Needle Exchange Programs: A Common Criticism Answered

    Directory of Open Access Journals (Sweden)

    Ksobiech Kate

    2004-04-01

    Full Text Available Abstract This study searched the available needle exchange program (NEP literature for return rate data. A total of 26 articles were found. The overall worldwide return rate was 90%, although this ranged from a low of 15% to a high of 112%. U.S. NEP return rates were gathered from only eight studies, indicating a clear need for more data, although U.S. return rates were comparable to those from NEPs outside of the U.S. One underlying assumption made by opponents of NEPs is that IDUs will not return needles to the distribution site, thereby potentially increasing the risk of health problems to the surrounding community from exposure to contaminated needles. This study's results suggest that NEPs are relatively successful in taking in used needles, although it is generally unclear where the needles were originally acquired, and if IDUs return their own needles, or are returning needles for a social network. Ways for AIDS Service Organizations to capitalize on these brief encounters with IDUs, as well as public policy implications of the findings, are discussed.

  16. In vivo Monitoring of Serotonin by Nanomaterial Functionalized Acupuncture Needle

    Science.gov (United States)

    Li, Yu-Tao; Tang, Li-Na; Ning, Yong; Shu, Qing; Liang, Feng-Xia; Wang, Hua; Zhang, Guo-Jun

    2016-06-01

    Acupuncture treatment is amazing but controversial. Up to now, the mechanism of treating diseases by acupuncture and moxibustion is still unclear, especially the occurrence of the molecular events in local acupoints. Herein, we report an extremely stable microsensor by modifying carbon nanotube (CNT) to the tip surface of acupuncture needle and applying this CNT-modified acupuncture needle for real time monitoring of serotonin (5-HT) in vivo. To stabilize CNT modification on the needle tip surface, poly(3,4-ethylenedioxythiophene)(PEDOT) was employed as glue water to stick CNT on the needle. The detection limit of the CNT-modified needle was found to be approximately 50 nM and 78 nM in the PBS and the cell medium, respectively. In addition, the needle showed good selectivity to some inflammatory mediators and some electroactive molecules. For the first time, the CNT-modified needle could be directly probed into rat body for real time monitoring of 5-HT in vivo, showing a great potential for better understanding the mechanism of acupuncture treatment.

  17. Comparison of dialysis and solid-phase extraction for isolation and concentration of dissolved organic matter prior to Fourier transform ion cyclotron resonance mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tfaily, Malak M.; Cooper, William T. [Florida State University, Department of Chemistry and Biochemistry, Tallahassee, FL (United States); Hodgkins, Suzanne; Chanton, Jeffrey P. [Florida State University, Department of Earth, Ocean and Atmospheric Science, Tallahassee, FL (United States); Podgorski, David C. [Florida State University, Department of Chemistry and Biochemistry, Tallahassee, FL (United States); Florida State University, National High Magnetic Field Laboratory, Tallahassee, FL (United States)

    2012-08-15

    We compare two methods, solid-phase extraction (SPE) and dialysis, commonly used for extraction and concentration of dissolved organic matter (DOM) prior to molecular characterization by electrospray ionization (ESI) and ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry. Spectra of DOM samples from Minnesota and Sweden peatlands that were extracted with styrene divinyl benzene polymer SPE sorbents included ions with formulas that had higher oxygen to carbon (O/C) ratios than spectra of DOM from the same samples after de-salting by dialysis. The SPE method was not very effective in extracting several major classes of DOM compounds that had high ESI efficiencies, including carboxylic acids and organo-sulfur compounds, and that out-competed other less-functionalized compounds (e.g., carbohydrates) for charge in the ESI source. The large abundance of carboxylic acids in the dialysisextracted DOM, likely the result of in situ microbial production, makes it difficult to see other (mainly hydrophilic) compounds with high O/C ratios. Our results indicate that, while dialysis is generally preferable for the isolation of DOM, for samples with high microbial inputs, the use of both isolation methods is recommended for a more accurate molecular representation. (orig.)

  18. PVA matches human liver in needle-tissue interaction.

    Science.gov (United States)

    de Jong, Tonke L; Pluymen, Loes H; van Gerwen, Dennis J; Kleinrensink, Gert-Jan; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-05-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Diagenesis of conifer needles in a coastal marine environment

    Science.gov (United States)

    Hedges, John I.; Weliky, K.

    1989-10-01

    Physically intact fir, hemlock and cedar needles were isolated from different horizons of a sediment core from a coastal marine bay (Dabob Bay, Washington State, U.S.A.) and from nearby trees and forest litter. Green fir, hemlock and cedar needles were all characterized by glucose-rich aldose mixtures (~30% of tissue carbon), the production of vanillyl and cinnamyl CuO-derived phenols (~8% of tissue carbon) and the presence of both pinitol and myo-inositol (1-2% of tissue carbon). Needles from forest litter were enriched in lignin phenols and non-glucose aldoses and depleted in glucose and cyclitols. The sediment core contained an average of 10 mg/1 of physically intact fir, hemlock and cedar needles, which occurred in similar relative abundances and accounted for less than 1% of the total nonwoody gymnosperm tissue. Compared to the green and litter counterparts, all sedimentary needles were greatly depleted in cyclitols, glucose and p-coumaric acid and enriched in vanillyl phenol precursors. The degree of elevation of vanillyl phenol yield from the degraded needles was used to estimate minimal carbon losses from the samples, which ranged from near 40% for needle litter to almost 70% for the deepest (~100 years old) sedimentary fir/hemlock samples. Although downcore increases in carbon loss and refractory organic components indicated in situ diagenesis, the bulk of overall degradation occurred either on land or during the first 10-20 years after deposition. Atomic C/N ratios of degraded needles were lower than for green counterparts, but nitrogen was lost overall. These relative changes indicate the following stability series: vanillyl phenols > N > ferulic acid, p-hydroxy phenols, most aldoses and bulk tissue > glucose and p-coumaric acid > cyclitols (near 100% loss). Vanillic acid to vanillin ratios, (Ad/Al)v, of the green fir and hemlock needles were unusually high (0.36-0.38) and decreased downcore. Diagenesis also decreased the cinnamyl/vanillyl phenol ratio

  20. Natural polymers: an overview

    CSIR Research Space (South Africa)

    John, MJ

    2012-08-01

    Full Text Available The scarcity of natural polymers during the world war years led to the development of synthetic polymers like nylon, acrylic, neoprene, styrene-butadiene rubber (SBR) and polyethylene. The increasing popularity of synthetic polymers is partly due...

  1. Dialysis Exercise Team: The Way to Sustain Exercise Programs in Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Alessandro Capitanini

    2014-07-01

    Full Text Available Patients affected by end-stage renal disease (ESRD show quite lower physical activity and exercise capacity when compared to healthy individuals. In addition, a sedentary lifestyle is favoured by lack of a specific counseling on exercise implementation in the nephrology care setting. Increasing physical activity level should represent a goal for every dialysis patient care management. Three crucial elements of clinical care may contribute to sustain a hemodialysis exercise program: a involvement of exercise professionals, b real commitment of nephrologists and dialysis professionals, c individual patient adaptation of the exercise program. Dialysis staff have a crucial role to encourage and assist patients during intra-dialysis exercise, but other professionals should be included in the ideal “exercise team” for dialysis patients. Evaluation of general condition, comorbidities (especially cardiovascular, nutritional status and physical exercise capacity are mandatory to propose an exercise program, in either extra-dialysis or intra-dialysis setting. To this aim, nephrologist should lead a team of specialists and professionals including cardiologist, physiotherapist, exercise physiologist, renal dietician and nurse. In this scenario, dialysis nurses play a pivotal role since they guarantee a constant and direct approach. Unfortunately dialysis staff may often lack of information and formation about exercise management while they take care patients during the dialysis session. Building an effective exercise team, promoting the culture of exercise and increasing physical activity levels lead to a more complete and modern clinical care management of ESRD patients.

  2. Impact of global economic disparities on practices and outcomes of chronic peritoneal dialysis in children: insights from the International Pediatric Peritoneal Dialysis Network Registry

    NARCIS (Netherlands)

    Schaefer, Franz; Borzych-Duzalka, Dagmara; Azocar, Marta; Munarriz, Reyner Loza; Sever, Lale; Aksu, Nejat; Barbosa, Lorena Sànchez; Galan, Yajaira Silva; Xu, Hong; Coccia, Paula A.; Szabo, Attila; Wong, William; Salim, Rosana; Vidal, Enrico; Pottoore, Stephen; Warady, Bradley A.; Alconcher, L.; Sojo, E.; Coccia, P. A.; Suarez, A.; Valles, P. G.; Salim, R.; Salta, S. A.; van Hoeck, K.; Koch, V.; Feber, J.; Geary, D. A.; White, C.; Valenzuela, M.; Villagra, J.; Cano, F.; Contreras, M. A.; Vogel, A.; Zambrano, P.; Berrocal, P.; Tse, K. C.; Xu, H.; Vondrak, K.; Rönnholm, K.; Harambat, J.; Ranchin, B.; Roussey, G.; Ulinski, T.; Fischbach, M.; Büscher, R.; Kemper, M.; Pape, L.; Schaefer, F.; Borzych, D.; Groothoff, J. W.

    2012-01-01

    BACKGROUND, OBJECTIVES, AND METHODS: The number of patients on chronic peritoneal dialysis (CPD) is increasing rapidly on a global scale. We analyzed the International Pediatric Peritoneal Dialysis Network (IPPN) registry, a global database active in 33 countries spanning a wide range in gross

  3. A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver.

    Science.gov (United States)

    Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay

    2018-01-01

    The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.

  4. Accumulation of Cs 137 by needles of pinus silvestris in various types of forest

    International Nuclear Information System (INIS)

    Golushko, R.M.

    2002-01-01

    It is researched accumulation of Cs 137 by needles of pine trees during growing old. It is shown, that needles of the one year old have more high radioactivity than needles of the two or three years old. Needles of pine trees accumulated more Cs 137 on good wet soils

  5. Asymptomatic Effluent Protozoa Colonization in Peritoneal Dialysis Patients.

    Science.gov (United States)

    Simões-Silva, Liliana; Correia, Inês; Barbosa, Joana; Santos-Araujo, Carla; Sousa, Maria João; Pestana, Manuel; Soares-Silva, Isabel; Sampaio-Maia, Benedita

    Currently, chronic kidney disease (CKD) is a global health problem. Considering the impaired immunity of CKD patients, the relevance of infection in peritoneal dialysis (PD), and the increased prevalence of parasites in CKD patients, protozoa colonization was evaluated in PD effluent from CKD patients undergoing PD. Overnight PD effluent was obtained from 49 asymptomatic stable PD patients. Protozoa analysis was performed microscopically by searching cysts and trophozoites in direct wet mount of PD effluent and after staining smears. Protozoa were found in PD effluent of 10.2% of evaluated PD patients, namely Blastocystis hominis, in 2 patients, and Entamoeba sp., Giardia sp., and Endolimax nana in the other 3 patients, respectively. None of these patients presented clinical signs or symptoms of peritonitis at the time of protozoa screening. Our results demonstrate that PD effluent may be susceptible to asymptomatic protozoa colonization. The clinical impact of this finding should be further investigated. Copyright © 2016 International Society for Peritoneal Dialysis.

  6. Circulating thyroid hormone levels and adequacy of dialysis.

    Science.gov (United States)

    Savdie, E; Stewart, J H; Mahony, J F; Hayes, J M; Lazarus, L; Simons, L A

    1978-02-01

    In vitro thyroid function tests were performed in three groups of patients with chronic renal failure who were receiving, on average, 15, 18 and 27 hours of maintenance hemodialysis per week. Total thyroxine levels were low and total triiodothyronine levels low to normal in those receiving the least dialysis (15 hours), and were significantly higher in those receiving longer dialysis. Free thyroxine levels, as measured by the effective thyroxine ratio, were normal and similar in all three groups, as were serum thyrotrophin levels. All patients were clinically euthyroid. As total hormone levels showed a significant inverse relationship to both urea and creatinine, this study suggests that there is a dialyzable metabolite retained in uremia which competes with thyroid hormones for protein-binding sites.

  7. [Just-in-time initiation of optimal dialysis].

    Science.gov (United States)

    Cornelis, Tom; Kooman, Jeroen P; van der Sande, Frank M

    2010-01-01

    The IDEAL trial shows that the decision to start renal replacement treatment should not depend on GFR alone, but should be taken on the basis of clinical parameters. Quality of Life (QoL) questionnaires and bio-impedance analysis are potential tools for detecting subtle changes in the predialysis clinic. Too early an initiation of dialysis may be deleterious for the patient and the healthcare system. We are convinced that ESRD patients should be informed about intensive haemodialysis (HD), especially nocturnal (home) HD, as the best available dialysis modality. There is substantial evidence which shows that intensive HD improves clinical, biochemical and biological parameters, and may even prolong survival. We believe that 'just-in-time delivery of intensive haemodialysis' may result in optimised QoL and reduced economic burden.

  8. Severe valproate induced hyperammonemic encephalopathy successfully managed with peritoneal dialysis.

    Science.gov (United States)

    Kumar, Amandeep; Suri, Ashish; Sharma, Bhawani S

    2014-07-01

    Valproic acid (VPA) is a commonly used drug for epilepsy, psychiatric disorders and migraine and is frequently used in neurosurgical intensive care units. Though most of its side-effects are mild and transient, certain idiosyncratic side-effects have been attributed to VPA. Valproate induced hyperammonemia (VIH) is one such side-effect. VIH can produce symptoms of encephalopathy known as valproate induced hyperammonemic encephalopathy (VHE). VIH and VHE usually respond to withdrawal of VPA. However, in some cases VHE can be unresponsive to supportive measures and severe enough to be life-threatening. In such cases, dialysis can be used to rapidly reverse hyperammonemia and VHE and can prove to be a lifesaving measure. We report such a case of VIH and life-threatening VHE in a postoperative neurosurgical patient that was managed successfully with peritoneal dialysis.

  9. Two Cases of Massive Hydrothorax Complicating Peritoneal Dialysis

    International Nuclear Information System (INIS)

    Bae, Sang Kyun; Yum, Ha Yong; Rim, Hark

    1994-01-01

    Massive hydrothorax complicating continuous ambulatory peritoneal dialysis (CAPD) is relatively rare. A 67-year-old male and a 23-year-old female patients during CAPD presented massive pleural effusion, They have been performing peritoneal dialysis due to end-stage renal disease for 8 months and 2 weeks respectively. We injected '9 9m Tc-labelled radiopharmaceutical (phytate and MAA, respectively) into peritoneal cavity with the dialysate. The anterior, posterior and right lateral images were obtained. The studies reveal visible radioactivity in the right chest indicating the communication between the peritoneal and the pleural space. After sclerotherapy with tetracycline, the same studies reveal no radioactivity in the right chest suggesting successful therapy. We think nuclear imaging is a simple and noninvasive method for the differential diagnosis of pleural effusion in patients during CAPD and the evaluation of therapy.

  10. Sonographic evaluation of complications in patients with peritoneal dialysis

    International Nuclear Information System (INIS)

    Yoo, Won Don; Jho, O. K.; Kim, J. S.; Ko, B. H.; Park, H. C.

    1990-01-01

    Ultrasonography was performed prospectively in 20 patients who were undergoing continuous ambullatory peritoneal dialysis for evaluation of complications. We examined the abdominal wall along the course of catheter and the peritoneal cavity with special attention to the dialysate distribution, dialysate echogenecity, thickness of the peritoneum small bowel distribution and the position of the catheter tip. Peritonitis was the most common complication (n=7); sonographic findings were small bowel adhesion (n=5) multiseptated ascites(n=1), peritoneal thickening(n=4), and tunnel infection(n=1) and exith site infection(n=1). Our initial experience suggests that ultrasonography is useful for diagnosis of complications and monitoring of patient during long term peritoneal dialysis

  11. Abdominal aortic calcifications predict survival in peritoneal dialysis patients

    DEFF Research Database (Denmark)

    Mäkelä, Satu M; Asola, Markku; Hadimeri, Henrik

    2018-01-01

    BACKGROUND: Peripheral arterial disease and vascular calcifications contribute significantly to the outcome of dialysis patients. The aim of this study was to evaluate the prognostic role of severity of abdominal aortic calcifications and peripheral arterial disease on outcome of peritoneal...... dialysis (PD) patients using methods easily available in everyday clinical practice. METHODS: We enrolled 249 PD patients (mean age 61 years, 67% male) in this prospective, observational, multicenter study from 2009 to 2013. The abdominal aortic calcification score (AACS) was assessed using lateral lumbar.......9) in 17%, and high (> 1.3) in 34% of patients. Altogether 91 patients (37%) died during the median follow-up of 46 months. Only 2 patients (5%) with AACS 0 died compared with 50% of the patients with AACS ≥ 7 (p

  12. Facile method to align crystalline needles composed of organic ...

    Indian Academy of Sciences (India)

    2017-09-23

    Sep 23, 2017 ... (using self-assembly) used for the purpose, its disadvantage is that a larger amount of the material dissolves in the solution than what ... Working hypothesis for aligning crystalline needles .... using a home-made equipment.

  13. NEEDLE ANATOMY CHANGES WITH INCREASING TREE AGE IN DOUGLAS FIR

    Science.gov (United States)

    Morphological differences between old growth and sapling (Pseudotsuga menziesii, (Mirb.) Franco) Douglas fir trees may extend to differences in needle anatomy. We used microscopy with image analysis to compare and quantify anatomical parameters in cross-sections of previous year...

  14. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  15. [Doctor HUANG Shi-ping's acupuncture with golden needles].

    Science.gov (United States)

    Chen, Teng-Fei; Ma, Zeng-Bin; Xin, Si-Yuan; Zhu, Jiang

    2013-08-01

    Taking Doctor HUANG Shi-ping as the representative, the school of Huang's golden needle is based on Chinese martial art. Golden needles are adopted as main tool. Attaching great importance on the combination of acupuncture and moxibustioin, it is also characterized with penetrating needling with long needles. Through the development of three generations, it once outshone other schools in the field of acupuncture, and became famous all over the world. It made great contribution to the development of the course of acupuncture. However, with the development of the history, the form of acupuncture education as well as apparatus were all undergone an unified reform. Therefore, Doctor HUANG Shi-ping's acupuncture school be lost gradually.

  16. High-pressure needle interface for thermoplastic microfluidics.

    Science.gov (United States)

    Chen, C F; Liu, J; Hromada, L P; Tsao, C W; Chang, C C; DeVoe, D L

    2009-01-07

    A robust and low dead volume world-to-chip interface for thermoplastic microfluidics has been developed. The high pressure fluidic port employs a stainless steel needle inserted into a mating hole aligned to an embedded microchannel, with an interference fit used to increase pressure resistance. Alternately, a self-tapping threaded needle screwed into a mating hole is also demonstrated. In both cases, the flat bottom needle ports seat directly against the microchannel substrate, ensuring low interfacial dead volumes. Low dispersion is observed for dye bands passing the interfaces. The needle ports offer sufficient pull-out forces for applications such as liquid chromatography that require high internal fluid pressures, with the epoxy-free interfaces compatible with internal microchannel pressures above 40 MPa.

  17. Should fine needle aspiration cytology in breast assessment be abandoned?

    International Nuclear Information System (INIS)

    Litherland, Janet C.

    2002-01-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  18. Low GDP Solution and Glucose-Sparing Strategies for Peritoneal Dialysis.

    Science.gov (United States)

    Szeto, Cheuk Chun; Johnson, David W

    2017-01-01

    Long-term exposure to a high glucose concentration in conventional peritoneal dialysis (PD) solution has a number of direct and indirect (via glucose degradation products [GDP]) detrimental effects on the peritoneal membrane, as well as systemic metabolism. Glucose- or GDP-sparing strategies often are hypothesized to confer clinical benefits to PD patients. Icodextrin (glucose polymer) solution improves peritoneal ultrafiltration and reduces the risk of fluid overload, but these beneficial effects are probably the result of better fluid removal rather than being glucose sparing. Although frequently used for glucose sparing, the role of amino acid-based solution in this regard has not been tested thoroughly. When glucose-free solutions are used in a combination regimen, published studies showed that glycemic control was improved significantly in diabetic PD patients, and there probably are beneficial effects on peritoneal function. However, the long-term effects of glucose-free solutions, used either alone or as a combination regimen, require further studies. On the other hand, neutral pH-low GDP fluids have been shown convincingly to preserve residual renal function and urine volume. The cost effectiveness of these solutions supports the regular use of neutral pH-low GDP solutions. Nevertheless, further studies are required to determine whether neutral pH-low GDP solutions exert beneficial effects on patient-level outcomes, such as peritonitis, technique survival, and patient survival. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Comparative clinical outcomes between pediatric and young adult dialysis patients.

    Science.gov (United States)

    Atkinson, Meredith A; Lestz, Rachel M; Fivush, Barbara A; Silverstein, Douglas M

    2011-12-01

    Published data on the comparative achievement of The Kidney Disease Dialysis Outcome Quality Initiative (KDOQI) recommended clinical performance targets between children and young adults on dialysis are scarce. To characterize the achievement of KDOQI targets among children (young adults (18-24 years) with prevalent end stage renal disease (ESRD), we performed a cross-sectional analysis of data collected by the Mid-Atlantic Renal Coalition, in conjunction with the 2007 and 2008 ESRD Clinical Performance Measures Projects. Data on all enrolled pediatric dialysis patients, categorized into three age groups (0-8, 9-12, 13-17 years), and on a random sample of 5% of patients ≥ 18 years in ESRD Network 5 were examined for two study periods: hemodialysis (HD) data were collected from October to December 2006 and from October to December 2007 and peritoneal dialysis (PD) data were collected from October 2006 to March 2007 and from October 2007 to March 2008. In total, 114 unique patients were enrolled the study, of whom 41.2% (47/114) were on HD and 58.8% (67/114) on PD. Compared to the pediatric patients, young adults were less likely to achieve the KDOQI recommended serum phosphorus levels and serum calcium × phosphorus product values, with less than one-quarter demonstrating values at or below each goal. Multivariate analysis revealed that both young adults and 13- to 17-year-olds were less likely to achieve target values for phosphorus [young adults: odds ratio (OR) 0.04, 95% confidence interval (95% CI) 0.01-0.19, p young adults: OR 0.01, 95% CI 0.002-0.09, p young adult ESRD patients.

  20. Croatian Recommendations for Dialysis of HIV-Positive Patients

    Directory of Open Access Journals (Sweden)

    Gulin Marijana

    2016-06-01

    Full Text Available Human immunodeficiency virus (HIV infection may be associated with renal impairment since about 0.4% of all HIV-positive patients develop end-stage renal disease. The share of patients with HIV infection in hemodialysis centers throughout the world ranges from 0.3% to as high as 38%. In Croatia, renal replacement therapy was needed by 1% of all the HIV-positive patients from 1985 until the end of 2014. Healthcare professionals (HP should be aware of the risks of occupational exposure to blood-borne infections in their daily work. Performing dialysis in HIV-positive patients increases the risk of exposure to HIV during the extracorporeal circulation of the infected blood. However, post-exposure prophylaxis (PEP with effective antiretroviral drugs significantly reduces the risk of infection after occupational exposure. On behalf of the Croatian Society of Nephrology, Dialysis and Transplantation, the authors of this paper have proposed recommendations for the management of HIVpositive patients on dialysis, which aim to prevent the transmission of HIV among patients and HPs. The important recommendations include the following: 1. when the need arises, it is necessary to provide HIV-positive patients with dialysis in the vicinity of their place of residence. 2. HIV-positive patients should be dialyzed with a separate hemodialysis machine in an isolated area. Alternatively, they can be dialyzed in an area for the hemodialysis of HCV-positive and/or HBVpositive patients. 3. Specialized and trained personnel should be provided during the hemodialysis procedure, together with strict compliance with the standard precautions for the prevention of blood-borne infections. 4. There should be a good and prompt cooperation with the National Referral Center for HIV infection.

  1. Cardiovascular morbidity and mortality risk factors in peritoneal dialysis patients

    Directory of Open Access Journals (Sweden)

    Jovanović Dijana B.

    2008-01-01

    Full Text Available Cardiovascular (CVS morbidity and mortality in the endstage renal disease (ESRD patients on peritoneal dialysis therapy is 10-30 folds higher than in general population. The prevalence of well known traditional risk factors such as age, sex, race, arterial hypertension, hyperlipidaemia, diabetes, smoking, physical inactivity is higher in the uraemic patients. Besides these, there are specific, nontraditional risk factors for dialysis patients. Mild inflammation present in peritoneal dialysis (PD patients which can be confirmed by specific inflammatory markers is the cause of CVS morbidity and mortality in these patients. Hypoalbuminaemia, hyperhomocysteinaemia and a higher level of leptin are important predictors of vascular complications as well as CVS events in the PD patients. Plasma norepinephrine, an indicator of sympathetic activity, is high in the ESRD patients and higher in the PD patients than in the patients on haemodialysis (HD. Therefore, norepinephrine may be a stronger risk factor in the PD patients. The same applies to asymmetric dimethylargine (ADMA, an endogenous inhibitor of nitric oxide synthase, which is an important risk factor of CVS morbidity and mortality 15 % higher in the PD than the HD patients. Hyperphosphataemia, secondary hyperparathyroidism and high calcium x phosphate product have been associated with the progression of the coronary artery calcification and valvular calcifications and predict all-cause CVS mortality in the PD patients. Residual renal function (RRF declines with time on dialysis but is slower in the PD than the HD patients. RRF decline is associated with the rise of proinflammatory cytokines and the onset of hypervolaemia and hypertension which increase the risk of CVS diseases, mortality in general and CVS mortality. In conclusion, it is very important to establish all CVS risk factors in the PD patients to prevent CVS diseases and CVS mortality in this population.

  2. Exercising during dialysis: a reflection on environmental\\ud barriers

    OpenAIRE

    Meddick, Leighan

    2016-01-01

    Research has demonstrated that exercise provides several physical and psychological benefits for hemodialysis patients, which include increasing their quality of life. However, implementing intra-dialytic exercise into the patients’ care schemes often proves to be a difficult task for dialysis providers, and they often run into barriers. Some of the environmental barriers that are often experienced are discussed herein, in order to raise awareness and provide recommendations which may result ...

  3. High fall incidence and fracture rate in elderly dialysis patients.

    Science.gov (United States)

    Polinder-Bos, H A; Emmelot-Vonk, M H; Gansevoort, R T; Diepenbroek, A; Gaillard, C A J M

    2014-12-01

    Although it is recognised that the dialysis population is ageing rapidly, geriatric complications such as falls are poorly appreciated, despite the many risk factors for falls in this population. The objective of this study was to determine the incidence, complications and risk factors for falls in an elderly dialysis population. A one-year observational study of chronic dialysis patients aged ≥ 70 years. At baseline, patient characteristics were noted and during follow-up the vital parameters and laboratory values were recorded. Patients were questioned weekly about falls, fall circumstances and consequences by trained nurses. 49 patients were included with a median age of 79.3 years (70-89 years). During follow-up 40 fall accidents occurred in 27 (55%) patients. Falls resulted in fractures in 15% of cases and in hospital admissions in 15%. In haemodialysis (HD) patients, the mean systolic blood pressure (SBP) before HD was lower in fallers compared with non-fallers (130 vs. 143 mmHg). Several patients in the lower blood pressure category received antihypertensive medication. For every 5 mmHg lower SBP (before HD) the fall risk increased by 30% (hazard ratio (HR) 1.30, 95% CI 1.03-1.65, p = 0.03). Furthermore, fall risk increased by 22% for every 10 pmol/l rise of parathyroid hormone (HR 1.22, 95% CI 1.06-1.39, p = 0.004). Elderly dialysis patients have a high incidence of falls accompanied by a high fracture rate. Given the high complication rate, elderly patients at risk of falling should be identified and managed. Reduction of blood pressure-lowering medication might be a treatment strategy to reduce falls.

  4. Peritoneal dialysis peritonitis by anaerobic pathogens: a retrospective case series

    OpenAIRE

    Chao, Chia-Ter; Lee, Szu-Ying; Yang, Wei-Shun; Chen, Huei-Wen; Fang, Cheng-Chung; Yen, Chung-Jen; Chiang, Chih-Kang; Hung, Kuan-Yu; Huang, Jenq-Wen

    2013-01-01

    Background Bacterial infections account for most peritoneal dialysis (PD)-associated peritonitis episodes. However, anaerobic PD peritonitis is extremely rare and intuitively associated with intra-abdominal lesions. In this study, we examined the clinical characteristics of PD patients who developed anaerobic peritonitis. Methods We retrospectively identified all anaerobic PD peritonitis episodes from a prospectively collected PD registry at a single center between 1990 and 2010. Only patient...

  5. Adverse Effects of Sporadic Dialysis on Body Composition.

    Science.gov (United States)

    Workeneh, Biruh; Shypailo, Roman; DeCastro, Iris; Shah, Maulin; Guffey, Danielle; Minard, Charles G; Mitch, William E

    2015-01-01

    The aim of this study is to analyze the body composition of patients receiving emergent dialysis and compare their body cell mass (BCM) and fat-free mass (FFM) with those of normal subjects. The care of patients receiving sporadic, emergent dialysis treatment is a growing public health concern and the magnitude of muscle wasting that occurs in this population is not known. We used a cross-sectional design with matching to determine differences in total body potassium--an indicator of both BCM and FFM--between emergent dialysis patients and healthy normal subjects. We studied 22 subjects using a 40K counter that measures BCM and FFM and compared them to controls after matching with sex, height and weight. In the matched comparison, BCM and FFM were significantly lower in subjects with end-stage renal disease (ESRD). Unadjusted BCM was 4.7 kg lower and FFM was 8.8 kg lower for those with ESRD compared to those without ESRD (p FFM (7.7 kg) in the ESRD subjects (p = 0.004). After adjusting for age, height, weight and gender, BCM and FFM were lower by 4.2 and 7.8 kg, respectively (p FFM loss over time was significant, with the ESRD subjects demonstrating 2.2 kg per year decline (p = 0.01). We conclude that among other consequences, muscle wasting indicated by decline in BCM and FFM is a significant concern in the growing emergent dialysis population. © 2015 S. Karger AG, Basel.

  6. Exploring the opinion of hemodialysis patients about their dialysis unit

    OpenAIRE

    Ahmed Farouk Donia; Mohamed Ahmed Elhadedy; Hanzada Mohamed El-Maghrabi; Mohamed Hamed Abbas; Mohamed Ashraf Foda

    2015-01-01

    Hemodialysis (HD) patients are subjected to a number of physical and mental stresses. Physicians might be unaware of some of these problems. We assessed our patients′ opinion about the service provided at the dialysis unit. Our unit has 89 patients on HD. A questionnaire exploring our patients′ opinion relative to the service provided was prepared. The patients were asked to fill-in the questionnaire in a confidential manner. Questionnaires were then collected and examined while unaware of pa...

  7. Efficacy of peritoneal dialysis during infusion and drainage procedures.

    Science.gov (United States)

    Baczyski, Daniel; Antosiewicz, Stefan; Waniewski, Jacek; Nowak, Zbigniew; Wakowicz, Zofia

    2010-01-01

    Inadequate dialysis is still a major cause of technique failure in peritoneal dialysis (PD). Mathematical models provide the possibility of direct and precise assessment of peritoneal transport of urea and creatinine throughout the dwell and allow calculation of optimal schedules, dwell times, and predicted adequacy of a prescribed regimen. Kinetic modeling is particularly important for automated PD. If the effectiveness of uremic toxin removal that takes place during infusion and drainage of dialysis fluid is not taken into account, the predicted adequacy of the whole PD session may be underestimated. ♢ To estimate the efficacy of urea and creatinine removal during the dialysis fluid exchange procedure. ♢ 17 patients treated with PD were included in the study. PD effectiveness during dialysate exchange was defined as the quotient k of removed amount of creatinine/BUN during the infusion and drainage of dialysate and during a dwell of the same duration as the dialysate exchange. ♢ The effectiveness of creatinine and urea removal was reduced during the exchange procedure (k(creat) = 0.68 ± 0.43 and k(BUN) = 0.87 ± 0.44) and differed between these 2 solutes (p = 0.0009). The k coefficients for urea and creatinine were well correlated (R(2) = 0.83). ♢ The effectiveness of peritoneal transport of creatinine and BUN during the inflow/outflow phase was relatively high compared to that during the same dwell time (68% and 87% respectively). This real effectiveness of the dialysate exchange procedure should be taken into account in the process of planning automated PD sessions, otherwise the predicted overall efficacy of creatinine and urea removal throughout the session may be underestimated. This underestimation is proportional to the number of dwells per day.

  8. [Acid-base status in patients treated with peritoneal dialysis].

    Science.gov (United States)

    Katalinić, Lea; Blaslov, Kristina; Pasini, Eva; Kes, Petar; Bašić-Jukić, Nikolina

    2014-04-01

    When compared to hemodialysis, peritoneal dialysis is very simple yet low cost method of renal replacement therapy. Series of studies have shown its superiority in preserving residual renal function, postponing uremic complications, maintaining the acid-base balance and achieving better post-transplant outcome in patients treated with this method. Despite obvious advantages, its role in the treatment of chronic kidney disease is still not as important as it should be. Metabolic acidosis is an inevitable complication associated with progressive loss of kidney function. Its impact on mineral and muscle metabolism, residual renal function, allograft function and anemia is very complex but can be successfully managed. The aim of our study was to evaluate the efficiency in preserving the acid-base balance in patients undergoing peritoneal dialysis at Zagreb University Hospital Center. Twenty-eight patients were enrolled in the study. The mean time spent on the treatment was 32.39 ± 43.43 months. Only lactate-buffered peritoneal dialysis fluids were used in the treatment. Acid-base balance was completely maintained in 73.07% of patients; 11.54% of patients were found in the state of mild metabolic acidosis, and the same percentage of patients were in the state of mild metabolic alkalosis. In one patient, mixed alkalosis with respiratory and metabolic component was present. The results of this study showed that acid-base balance could be maintained successfully in patients undergoing peritoneal dialysis, even only with lactate-buffered solutions included in the treatment, although they were continuously proclaimed as inferior in comparison with bicarbonate-buffered ones. In well educated and informed patients who carefully use this method, accompanied by the attentive and thorough care of their physicians, this method can provide quality continuous replacement of lost renal function as well as better quality of life.

  9. Disseminated Mycobacterium abscessus infection in a peritoneal dialysis patient

    Directory of Open Access Journals (Sweden)

    Vincent H.J.F. Mooren

    2017-01-01

    Full Text Available A disseminated peritoneal dialysis-related Mycobacterium abscessus infection is very rare. M. abscessus belongs to the rapidly growing mycobacteria and can be misidentified as a diphtheroid bacterium, which in our case delayed diagnosis and optimal treatment. Due to intrinsic resistance to most antimicrobials, therapeutic options in M. abscessus infections are limited. Infection often leads to catheter loss. A fatal outcome, like in our case, is not exceptional.

  10. Metabolic Profiling of Impaired Cognitive Function in Patients Receiving Dialysis

    OpenAIRE

    Kurella Tamura, Manjula; Chertow, Glenn M.; Depner, Thomas A.; Nissenson, Allen R.; Schiller, Brigitte; Mehta, Ravindra L.; Liu, Sai; Sirich, Tammy L.

    2016-01-01

    Retention of uremic metabolites is a proposed cause of cognitive impairment in patients with ESRD. We used metabolic profiling to identify and validate uremic metabolites associated with impairment in executive function in two cohorts of patients receiving maintenance dialysis. We performed metabolic profiling using liquid chromatography/mass spectrometry applied to predialysis plasma samples from a discovery cohort of 141 patients and an independent replication cohort of 180 patients partici...

  11. Toxicity testing of polymer materials for dialysis equipment: reconsidering in vivo testing.

    Science.gov (United States)

    Sauer, U G; Liebsch, M; Kolar, R

    2000-01-01

    In fulfilment of the aims of the European Union Biocidal Directive (Directive 98/8/EC), Technical Guidance Documents are currently being compiled. Part I of these Technical Guidance Documents covers data requirements for active substances and biocidal products. The Three Rs principle has been applied in certain parts of the toxicity and ecotoxicity testing scheme for pesticides, such as testing for acute oral toxicity, skin and eye irritation, skin sensitisation, and dermal absorption. Further recommendations on how to proceed with regard to the continuing replacement, reduction and refinement of animal experiments in this field of regulatory testing are included for consideration. In this context, besides stressing the necessity to validate and accept further alternatives, emphasis is placed on providing the possibility of waiving unnecessary tests and on the continuous evaluation of whether certain tests are needed at all. 2000 FRAME.

  12. Susuks (charm needles) in the craniofacial region

    International Nuclear Information System (INIS)

    Nambiar, P.; Ibrahim, N.; Tandjung, Y.R.M.; Shanmuhasuntharam, P.

    2008-01-01

    We conducted a study to determine the numbers of susuks (charm needles) and their distribution in the craniofacial region of susuk wearers, and the sex, racial affiliation, and age of the wearers. In addition, we sought to determine whether the presence of susuks posed any potential hazard to patients undergoing magnetic resonance imaging (MRI). We studied various radiographs of 33 susuk wearers (age range, 33-69 years) and investigated the most common sites of insertion in the craniofacial region. A susuk was also suspended inside a 1.5-T MRI machine to determined whether it was attracted by the machine's magnet. The largest number of susuks that we observed in the craniofacial region was 39 pins, and susuks were particularly numerous in Malay Muslim women. Other sites with susuks were the maxillofacial region (except the temporomandibular region) and the forehead. The susuks showed no ferromagnetic characteristics. As susuks are made from gold, they are generally biocompatible with human tissue and do not cause problems to their wearers. Gold and the other minor metal constituents found in susuks have no ferromagnetic characteristics and therefore pose no hazard to patients undergoing MRI. (author)

  13. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  14. Fine needle aspiration cytology of dermal cylindroma

    Directory of Open Access Journals (Sweden)

    Parikshaa Gupta

    2014-01-01

    Full Text Available In this paper, we have described fine needle aspiration cytology (FNAC of a rare case of dermal cylindroma. A 40-year-old female presented with a lateral mid-cervical swelling fixed to the skin. FNAC smears showed multiple clusters of small, round to oval cells with hyperchromatic nuclei, inconspicuous nucleoli and scant cytoplasm. In addition, the background showed deposits of basement membrane type material. This was dark magenta colored pinkish globular material. The globules were occasionally surrounded by the basal type of cells. Occasional cells with elongated nuclei were also noted. Cytological diagnosis of skin adnexal tumor possibly cylindroma was offered. Subsequent histopathology of the swelling showed sheets and clusters of cells in a jigsaw puzzle-like fashion. Deposition of abundant basement membrane-like material was noted in between the tumor cells. A diagnosis of cylindorma was offered. FNAC along with the subcutaneous location of the tumor and absence of primary salivary gland tumor may help to diagnose such rare case.

  15. Fine needle aspiration cytology in leprosy

    Directory of Open Access Journals (Sweden)

    Prasad PVS

    2008-01-01

    Full Text Available Background: Laboratory diagnosis of leprosy by slit skin smear and skin biopsy is simple but both techniques have their own limitations. Slit skin smear is negative in paucibacillary cases whereas skin biopsy is an invasive technique. Fine needle aspiration cytology (FNAC from skin lesions in leprosy with subsequent staining with May-Grunwald-Giemsa (MGG stain has been found useful. Aim: To evaluate the possible role of cytology in classifying leprosy patients. Methods: Seventy-five untreated cases of leprosy attending the outpatient department were evaluated. Smears were taken from their skin lesions and stained using the MGG technique. Skin biopsy was also done from the lesions, which was compared with cytology smears. Results: A correlation of clinical features with FNAC was noticed in 87.5% of TT, 92.1% of BT, 81% of BL, and 66% of LL cases. Correlation of clinical with histopathological diagnoses revealed 12.5% specificity in TT leprosy, 55.3% in BT, 52.4% in BL and 50% in LL, and 100% in neuritic and histoid leprosy cases. Both correlations were found to be statistically significant by paired t test analysis. Thus, it was possible to distinguish the tuberculoid types by the presence of epithelioid cells and the lepromatous types by the presence of lymphocytes and foamy macrophages. Conclusion: FNAC may be used to categorize the patients into paucibacillary and multibacillary types, but is not a very sensitive tool to classify the patients across the Ridley-Jopling spectrum.

  16. Chondromalacia patellae treated by warming needle and rehabilitation training.

    Science.gov (United States)

    Qiu, Ling; Zhang, Min; Zhang, Ji; Gao, Le-Nv; Chen, Da-wei; Liu, Jun; She, Jia-yi; Wang, Ling; Yu, Jin-yan; Huang, Le-ping; Bai, Yang

    2009-06-01

    To observe the effect of warming needle combined with rehabilitation training on chondromalacia patellae in a randomized controlled trial. The 92 cases were randomly divided into a treatment group treated by warming needle plus rehabilitation training (47 cases) and a control group treated by medication plus rehabilitation training (45 cases), and the therapeutic effect was compared after 20 sessions. The pain was relieved more obviously in the treatment group than in the control group (P chondromalacia patellae.

  17. Polymer dynamics from synthetic polymers to proteins

    Indian Academy of Sciences (India)

    Keywords. Polymer dynamics; reptation; domain dynamics biomolecules. Abstract. Starting from the standard model of polymer motion - the Rouse model - we briefly present some key experimental results on the mesoscopic dynamics of polymer systems. We touch the role of topological confinement as expressed in the ...

  18. Pulmonary hypertenstion ad leading factor in patients undergoing dialysis

    International Nuclear Information System (INIS)

    Rehman, I.U.; Sumera, A.; Idrees, M.K.; Tanweer, A.

    2014-01-01

    Objective: To determine the frequency and leading factors of pulmonary hypertension among chronic hemodialysis patients. Study Design: Case series. Place and Duration of Study: Hemodialysis Unit, Department of Nephrology, Sindh Institute of Urology and Transplantation, Karachi, from September 2011 to March 2012. Methodology: Patients of either gender aged between 16 to 60 years of age undergoing hemodialysis for at least 3 months not having pre-existing valvular heart disease, chronic lung disease or connective tissue disorder were included. Pulmonary hypertension was prospectively estimated by Doppler echocardiogram on patients undergoing dialysis. Pulmonary artery pressure was calculated on the post-dialysis day and leading factors were compared between patients with and without pulmonary hypertension. Results: A total of 178 patients were included in study with male to female ratio120/58 (2.06:1). The mean age was 33.84 +- 11.9 years. The mean duration of hemodialysis was 23.85 +- 22.48 months. Pulmonary hypertension was found in 76 (42.7%) patients. Out of the studied factors, low serum albumin ( 3.4 mg/dl, p = 0.01) was found to be statistically significant in patients with pulmonary hypertension. Conclusion: Pulmonary hypertension was frequently present in dialysis population (42.7%). This subset of patients had significantly lower albumin levels in serum. More research is needed in its pathogenesis to arrest its course. (author)

  19. Serum sodium and mortality in a national peritoneal dialysis cohort.

    Science.gov (United States)

    Ravel, Vanessa A; Streja, Elani; Mehrotra, Rajnish; Sim, John J; Harley, Kevin; Ayus, Juan Carlos; Amin, Alpesh N; Brunelli, Steven M; Kovesdy, Csaba P; Kalantar-Zadeh, Kamyar; Rhee, Connie M

    2017-07-01

    Sodium disarrays are common in peritoneal dialysis (PD) patients, and may be associated with adverse outcomes in this population. However, few studies of limited sample size have examined the association of serum sodium with mortality in PD patients, with inconsistent results. We hypothesized that both hypo- and hypernatremia are associated with higher death risk in a nationally representative cohort of US PD patients. We sought to examine the association of serum sodium over time and mortality among 4687 adult incident PD patients from a large US dialysis organization who underwent one or more serum sodium measurements within the first 3 months of dialysis over January 2007 to December 2011. We examined the association of time-dependent and baseline sodium with all-cause mortality as a proxy of short- and long-term sodium-mortality associations, respectively. Hazard ratios were estimated using Cox models with three adjustment levels: minimally adjusted, case-mix adjusted, and case-mix + laboratory adjusted. In time-dependent analyses, sodium levels mortality remained significant for levels mortality risk across all models (ref: 140 to <142 mEq/L). In PD patients, lower time-dependent and baseline sodium levels were independently associated with higher death risk. Further studies are needed to determine whether correction of dysnatremia improves longevity in this population. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  20. Predictive Modelling Risk Calculators and the Non Dialysis Pathway.

    Science.gov (United States)

    Robins, Jennifer; Katz, Ivor

    2013-04-16

    This guideline will review the current prediction models and survival/mortality scores available for decision making in patients with advanced kidney disease who are being considered for a non-dialysis treatment pathway. Risk prediction is gaining increasing attention with emerging literature suggesting improved patient outcomes through individualised risk prediction (1). Predictive models help inform the nephrologist and the renal palliative care specialists in their discussions with patients and families about suitability or otherwise of dialysis. Clinical decision making in the care of end stage kidney disease (ESKD) patients on a non-dialysis treatment pathway is currently governed by several observational trials (3). Despite the paucity of evidence based medicine in this field, it is becoming evident that the survival advantages associated with renal replacement therapy in these often elderly patients with multiple co-morbidities and limited functional status may be negated by loss of quality of life (7) (6), further functional decline (5, 8), increased complications and hospitalisations. This article is protected by copyright. All rights reserved.

  1. Self-management support for peritoneal dialysis patients.

    Science.gov (United States)

    Sarian, Mari; Brault, Diane; Perreault, Nathalie

    2012-01-01

    The increasing prevalence of chronic illnesses and kidney disease, in particular, makes it necessary to adopt new approaches towards their management (Wagner, 1998). Evidence suggests that promoting self-management improves the health status of peritoneal dialysis (PD) patients, as they manage upwards of 90% of their own care. Patients who are unable to self-manage suffer from various complications. This project proposes an intervention aimed at improving self-management skills among PD patients. To promote self-management in peritoneal dialysis patients. This is achieved through the following objectives: (a) develop an algorithm that can improve patients' ability to solve the specific problem of fluid balance maintenance, (b) develop an educational session for patients on how to use the algorithm, and (c) develop an implementation strategy in collaboration with the PD nurse. Three measures evaluate the effectiveness of the intervention. First, a telephone call log shows that participating patients call the clinic less to inquire about fluid balance maintenance. Next, a pre- and post-intervention knowledge test measures definite knowledge increase. Finally, a Patient Satisfaction Questionnaire reveals overall satisfaction with the intervention. This project, which proved beneficial to our patient population, could be duplicated in other clinics. The algorithm "How do I choose a dialysis bag" and the slides of the educational sessions can be shared with PD nurses across the country for the benefit of PD patients.

  2. DIALYSIS SERVICES’ INFECTED WASTE: A DISCUSSION ABOUT ITS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Izilda Simões Vitorino Eliam

    2006-12-01

    Full Text Available ABSTRACT: Professionals of the dialysis services face risky situations since from the accomplishment of the pratical procedures to the management of the different kinds of waste generated in these services. Accidents with needlestick materials represent one of the biggest risks for workers of the health. The objective was to characterize the management of infected waste in the dialysis services in Goiânia - GO. This is a descriptive study, with data collected in 2004, march, by check list elaborated accordancing to RDC 33/ 03/ANVISA, previously validated, with ethical and legal aspects observed and legal allowance of the eleven services. It was clearly shown that the discharging of needlestick materials is done specific by four units of service; seven services improvise the container, using bottles of dialysis solution, in order to deischarge the materials. In eight services milky white bags were used to discharge the dialysers. The segregation of the needlestick material waste does happen next to the generating source in the majority of the units (91%. The majority of the units didn’t have dustbin for infected waste with covers in motion for pedal. The internal transport is made manually in 82% of the services. This study concluded that in the majority of the researched services, the management of the waste does not follow the biosecurity rules, increasing the collective biological risk. KEYWORDS: Medical Waste; Hospital Hemodialysis Units; Enviroment.

  3. Residual Renal Function in Children Treated with Chronic Peritoneal Dialysis

    Directory of Open Access Journals (Sweden)

    Maria Roszkowska-Blaim

    2013-01-01

    Full Text Available Residual renal function (RRF in patients with end-stage renal disease (ESRD receiving renal replacement therapy is defined as the ability of native kidneys to eliminate water and uremic toxins. Preserved RRF improves survival and quality of life in adult ESRD patients treated with peritoneal dialysis. In children, RRF was shown not only to help preserve adequacy of renal replacement therapy but also to accelerate growth rate, improve nutrition and blood pressure control, reduce the risk of adverse myocardial changes, facilitate treatment of anemia and calcium-phosphorus balance abnormalities, and result in reduced serum and dialysate fluid levels of advanced glycation end-products. Factors contributing to RRF loss in children treated with peritoneal dialysis include the underlying renal disease such as hemolytic-uremic syndrome and hereditary nephropathy, small urine volume, severe proteinuria at the initiation of renal replacement therapy, and hypertension. Several approaches can be suggested to decrease the rate of RRF loss in pediatric patients treated with chronic peritoneal dialysis: potentially nephrotoxic drugs (e.g., aminoglycosides, episodes of hypotension, and uncontrolled hypertension should be avoided, urinary tract infections should be treated promptly, and loop diuretics may be used to increase salt and water excretion.

  4. Adherence of pediatric patients to automated peritoneal dialysis.

    Science.gov (United States)

    Chua, Annabelle N; Warady, Bradley A

    2011-05-01

    Little information is available on adherence to a home automated peritoneal dialysis (APD) prescription for children with end-stage renal disease. We have therefore retrospectively reviewed HomeChoice PRO Card data from patients Adherence was characterized as occurring ≥ 95%, 90-94%, or treatment adherence and patient age, gender, race and if the patient had received training, respectively, was assessed. Of the 51 patients (57% male), with a mean age at peritoneal dialysis (PD) onset of 11.8 ± 5.3 years, 28 (55%) were adherent for all variables. No difference in mean age or if patients were trained existed between the two groups. Males were more likely to be non-adherent (p = 0.026) as were African Americans (p = 0.048). The majority of patients were adherent to duration (96%) and number of cycles (92%), whereas non-adherence was more common with number of sessions (82%) and dialysate volume (78%). In conclusion, 45% of the pediatric patients in our study cohort exhibited some non-adherence to their prescribed APD regimen, emphasizing the value of closely monitoring the performance of home dialysis in children.

  5. Pleuroperitoneal leak complicating peritoneal dialysis: a case series.

    LENUS (Irish Health Repository)

    Kennedy, C

    2012-02-01

    Pressure related complications such as abdominal wall hernias occur with relative frequency in patients on peritoneal dialysis. Less frequently, a transudative pleural effusion containing dialysate can develop. This phenomenon appears to be due to increased intra-abdominal pressure in the setting of congenital or acquired diaphragmatic defects. We report three cases of pleuroperitoneal leak that occurred within a nine-month period at our institution. We review the literature on this topic, and discuss management options. The pleural effusion resolved in one patient following drainage of the peritoneum and a switch to haemodialysis. One patient required emergency thoracocentesis. The third patient developed a complex effusion requiring surgical intervention. The three cases highlight the variability of this condition in terms of timing, symptoms and management. The diagnosis of a pleuroperitoneal leak is an important one as it is managed very differently to most transudative pleural effusions seen in this patient population. Surgical repair may be necessary in those patients who wish to resume peritoneal dialysis, or in those patients with complex effusions. Pleuroperitoneal leak should be considered in the differential diagnosis of a pleural effusion, particularly a right-sided effusion, in a patient on peritoneal dialysis.

  6. [Diverticular disease of the colon in peritoneal dialysis].

    Science.gov (United States)

    Buemi, M; Aloisi, C; Romeo, A; Sturiale, A; Barilla', A; Cosentini, V; Aloisi, E; Corica, F; Ruello, A; Frisina, N

    2002-01-01

    Colon diverticular disease is a very common pathology in western countries and represents a risk factor for septic-type complications, especially in peritoneal dialysis patients. We examined both diagnostic procedure and therapeutics options, either pharmacological or surgical. Ultrasonography, which is useful for the diagnosis of diverticulosis and diverticular disease, has been supported in the last few years by new imaging techniques, such as NMR and CT, that also find applications in the treatment of diverticulitis complications like peritoneal abscesses. Our emphasis is on the therapeutic perspective, either dietetic - based on the use of a fibre-rich diet and the infusion of liquids by intravenous injection - or surgical, such as the Hartmann procedure, single anastomosis with stomia conservation and laparoscopic and endoscopic treatment. These therapeutic approaches have reduced both morbidity and mortality rate and have emphasized how the reduction of surgical stress on the mesothelium promotes the recovery of the functional integrity and, consequently, faster resumption of peritoneal dialysis. In conclusion, diverticulosis alone is not a contraindication for peritoneal dialysis, but constitutes a risk factor for the continuation of this alternative treatment.

  7. A simulation model to estimate the cost and effectiveness of alternative dialysis initiation strategies.

    Science.gov (United States)

    Lee, Chris P; Chertow, Glenn M; Zenios, Stefanos A

    2006-01-01

    Patients with end-stage renal disease (ESRD) require dialysis to maintain survival. The optimal timing of dialysis initiation in terms of cost-effectiveness has not been established. We developed a simulation model of individuals progressing towards ESRD and requiring dialysis. It can be used to analyze dialysis strategies and scenarios. It was embedded in an optimization frame worked to derive improved strategies. Actual (historical) and simulated survival curves and hospitalization rates were virtually indistinguishable. The model overestimated transplantation costs (10%) but it was related to confounding by Medicare coverage. To assess the model's robustness, we examined several dialysis strategies while input parameters were perturbed. Under all 38 scenarios, relative rankings remained unchanged. An improved policy for a hypothetical patient was derived using an optimization algorithm. The model produces reliable results and is robust. It enables the cost-effectiveness analysis of dialysis strategies.

  8. Impact of facility size and profit status on intermediate outcomes in chronic dialysis patients.

    Science.gov (United States)

    Frankenfield, D L; Sugarman, J R; Presley, R J; Helgerson, S D; Rocco, M V

    2000-08-01

    Little information is available regarding the influence of dialysis facility size or profit status on intermediate outcomes in chronic dialysis patients. We have combined data from the Health Care Financing Administration (HCFA) Core Indicators Project; the end-stage renal disease (ESRD) facility survey; and the HCFA On-Line Survey, Certification, and Reporting System to analyze trends in this area. For hemodialysis patients, larger facilities were more likely than smaller facilities to perform dialysis on patients who were younger than 65 years of age, black, or undergoing dialysis 2 years or more (P profit units (P reduction ratio, but not with hematocrit or serum albumin values. Facility profit status was not associated with these intermediate outcomes. For peritoneal dialysis patients, there were no significant differences in patient demographics based on facility size. More patients in nonprofit units had been undergoing dialysis 2 or more years than patients in for-profit units (P profit status.

  9. Novel design of honeybee-inspired needles for percutaneous procedure.

    Science.gov (United States)

    Sahlabadi, Mohammad; Hutapea, Parsaoran

    2018-04-18

    The focus of this paper is to present new designs of innovative bioinspired needles to be used during percutaneous procedures. Insect stingers have been known to easily penetrate soft tissues. Bioinspired needles mimicking the barbs in a honeybee stinger were developed for a smaller insertion force, which can provide a less invasive procedure. Decreasing the insertion force will decrease the tissue deformation, which is essential for more accurate targeting. In this study, some design parameters, in particular, barb shape and geometry (i.e. front angle, back angle, and height) were defined, and their effects on the insertion force were investigated. Three-dimensional printing technology was used to manufacture bioinspired needles. A specially-designed insertion test setup using tissue mimicking polyvinyl chloride (PVC) gels was developed to measure the insertion and extraction forces. The barb design parameters were then experimentally modified through detailed experimental procedures to further reduce the insertion force. Different scales of the barbed needles were designed and used to explore the size-scale effect on the insertion force. To further investigate the efficacy of the proposed needle design in real surgeries, preliminary ex vivo insertion tests into bovine liver tissue were performed. Our results show that the insertion force of the needles in different scales decreased by 21-35% in PVC gel insertion tests, and by 46% in bovine liver tissue insertion tests.

  10. Needle stick injury in a radiology department: a decade analysis

    International Nuclear Information System (INIS)

    Sayani, R.; Rajani, A.

    2012-01-01

    Objectives: To determine the frequency of needle stick injury in health care workers of radiology department. Study type, settings and duration: Cross sectional, observational study conducted at the Radiology department of Aga Khan University hospital from January 2000 to May 2010. Subject and Methods: All self-reported needle stick injuries data of Health care workers of radiology department was recorded. The personnel involved (Radiologist, resident, radiographer, nurses etc), area of working and the causes of injury were identified including the procedural or post procedural details. Patient's status of hepatitis or blood borne infection was also noted. Data was recorded and analyzed in Excel worksheet. Results: A total of 55 health workers reported needle stick injuries at all sections of radiology departments with maximum number needle stick injuries at general radiography, fluoroscopy and IVP section. Radiographers and radiology residents received the maximum number of injuries. Major cause of injury was cannulation however, many injuries occurred during disposing or handling of bin. In majority of cases the patients were not infected with any known blood borne infections. Conclusions: Doctors and nurses get needle-stick injuries while carrying out clinical procedures, while, ancillary staff get infected post procedure during disposal of garbage. Policy message: Good occupational health and safety practices must be promoted to all staff. Safer disposal of needles is an important area where practice and procedure needs to be carefully reviewed. It is necessary to undertake a risk assessment, to offer counseling and Post Exposure Prophylaxis and treatment where necessary. (author)

  11. Dry needling in lateral epicondylitis: a prospective controlled study.

    Science.gov (United States)

    Uygur, Esat; Aktaş, Birol; Özkut, Afşar; Erinç, Samet; Yilmazoglu, Emime Gül

    2017-11-01

    Lateral epicondylitis (LE), a common disease, especially in middle age, causes decreased productivity and economic losses. The first-line treatment for LE is conservative and consists of topical and oral anti-inflammatory drugs, ice application, and brace use. If the first-line treatment fails, second-line treatment modalities, which are generally invasive, are offered. Second-line therapeutic regimens include saline, corticosteroid, or platelet-rich plasma injections. Dry needling is relatively new. We hypothesized that dry needling would be at least as effective as first-line treatment for LE. We compared the outcomes of first-line treatment and dry needling. The study allocated 110 patients into groups using online randomization software. After completing the Patient-rated Tennis Elbow Evaluation (PRTEE), patients in group I received dry needling, whereas those in group II received first-line treatment, consisting of ibuprofen 100 mg twice a day and a proximal forearm brace. The patients were evaluated after three weeks and six months. The study ultimately analyzed 92 patients. Although both treatment methods were effective at three weeks, dry needling was significantly more effective than the first-line treatment at six months. Because of the low complication rate, dry needling is a safe method, and it might be an effective treatment option for LE.

  12. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2011-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retrac...

  13. Factors influencing access to education, decision making, and receipt of preferred dialysis modality in unplanned dialysis start patients

    DEFF Research Database (Denmark)

    Machowska, Anna; Alscher, Mark Dominik; Vanga, Satyanarayana Reddy

    2016-01-01

    for patients receiving education, making a decision, and receiving their preferred modality choice in UPS patients following a UPS educational program (UPS-EP). Methods: The Offering Patients Therapy Options in Unplanned Start (OPTiONS) study examined the impact of the implementation of a specific UPS......-EP, including decision support tools and pathway improvement on dialysis modality choice. Linear regression models were used to examine the factors predicting three key steps: referral and receipt of UPS-EP, modality decision making, and actual delivery of preferred modality choice. A simple economic assessment...... was performed to examine the potential benefit of implementing UPS-EP in terms of dialysis costs. Results: The majority of UPS patients could receive UPS-EP (214/270 patients) and were able to make a decision (177/214), although not all patients received their preferred choice (159/177). Regression analysis...

  14. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  15. A study on the information-motivation-behavioural skills model among Chinese adults with peritoneal dialysis.

    Science.gov (United States)

    Chang, Tian-Ying; Zhang, Yi-Lin; Shan, Yan; Liu, Sai-Sai; Song, Xiao-Yue; Li, Zheng-Yan; Du, Li-Ping; Li, Yan-Yan; Gao, Douqing

    2018-05-01

    To examine whether the information-motivation-behavioural skills model could predict self-care behaviour among Chinese peritoneal dialysis patients. Peritoneal dialysis is a treatment performed by patients or their caregivers in their own home. It is important to implement theory-based projects to increase the self-care of patients with peritoneal dialysis. The information-motivation-behavioural model has been verified in diverse populations as a comprehensive, effective model to guide the design, implementation and evaluation of self-care programmes. A cross-sectional, observational study. A total of 201 adults with peritoneal dialysis were recruited at a 3A grade hospital in China. Participant data were collected on demographics, self-care information (knowledge), social support (social motivation), self-care attitude (personal motivation), self-efficacy (behaviour skills) and self-care behaviour. We also collected data on whether the recruited patients had peritoneal dialysis-associated peritonitis from electronic medical records. Measured variable path analysis was performed using mplus 7.4 to identify the information-motivation-behavioural model. Self-efficacy, information and social motivation predict peritoneal dialysis self-care behaviour directly. Information and personal support affect self-care behaviour through self-efficacy, whereas peritoneal dialysis self-care behaviour has a direct effect on the prevention of peritoneal dialysis-associated peritonitis. The information-motivation-behavioural model is an appropriate and applicable model to explain and predict the self-care behaviour of Chinese peritoneal dialysis patients. Poor self-care behaviour among peritoneal dialysis patients results in peritoneal dialysis-associated peritonitis. The findings suggest that self-care education programmes for peritoneal dialysis patients should include strategies based on the information-motivation-behavioural model to enhance knowledge, motivation and behaviour

  16. Improving Dialysis Adherence for High Risk Patients Using Automated Messaging: Proof of Concept

    OpenAIRE

    Som, A.; Groenendyk, J.; An, T.; Patel, K.; Peters, R.; Polites, G.; Ross, W. R.

    2017-01-01

    Comorbidities and socioeconomic barriers often limit patient adherence and self-management with hemodialysis. Missed sessions, often associated with communication barriers, can result in emergency dialysis and avoidable hospitalizations. This proof of concept study explored using a novel digital-messaging platform, EpxDialysis, to improve patient-to-dialysis center communication via widely available text messaging and telephone technology. A randomized controlled trial was conducted through W...

  17. Arthritis associated with calcium oxalate crystals in an anephric patient treated with peritoneal dialysis

    International Nuclear Information System (INIS)

    Rosenthal, A.; Ryan, L.M.; McCarty, D.J.

    1988-01-01

    The authors report a case of calcium oxalate arthropathy in a woman undergoing intermittent peritoneal dialysis who was not receiving pharmacologic doses of ascorbic acid. She developed acute arthritis, with calcium oxalate crystals in Heberden's and Bouchard's nodes, a phenomenon previously described in gout. Intermittent peritoneal dialysis may be less efficient than hemodialysis in clearing oxalate, and physicians should now consider calcium oxalate-associated arthritis in patients undergoing peritoneal dialysis who are not receiving large doses of ascorbic acid

  18. Medication burden in CKD-5D: impact of dialysis modality and setting

    OpenAIRE

    Parker, Kathrine; Nikam, Milind; Jayanti, Anuradha; Mitra, Sandip

    2014-01-01

    Background Medication adherence is thought to be around 50% in the general and dialysis population. Reducing the pill burden (PB) reduces regime complexity and can improve adherence. Increased adherence should lead to improvement in treatment outcomes and patient quality of life. There is currently little published data on PB in CKD-5D across dialysis modalities. Methods This is a retrospective, single renal network study. All in-centre HD (MHD), peritoneal dialysis (PD) and home HD (HHD) pat...

  19. Pneumococcal peritonitis in peritoneal dialysis - three case reports and literature review

    OpenAIRE

    Pereira, Tiago Assis; Vizinho, Ricardo; Branco, Patricia; Gaspar, Augusta; Barata, José Diogo

    2015-01-01

    Peritonitis and catheter-related infections are a frequent complication in peritoneal dialysis, usually driven by commensal microorganisms. They carry a significant morbidity and mortality burden and have known consequences on viability of peritoneal dialysis and patient survival. This article describes three clinical cases, in which three different peritoneal dialysis patients presented pneumococcal peritonitis, two of which were related with obvious previous or concomitant respiratory sympt...

  20. Transcription through the eye of a needle: daily and annual cyclic gene expression variation in Douglas-fir needles

    OpenAIRE

    Cronn, Richard; Dolan, Peter C.; Jogdeo, Sanjuro; Wegrzyn, Jill L.; Neale, David B.; St. Clair, J. Bradley; Denver, Dee R.

    2017-01-01

    Background Perennial growth in plants is the product of interdependent cycles of daily and annual stimuli that induce cycles of growth and dormancy. In conifers, needles are the key perennial organ that integrates daily and seasonal signals from light, temperature, and water availability. To understand the relationship between seasonal cycles and seasonal gene expression responses in conifers, we examined diurnal and circannual needle mRNA accumulation in Douglas-fir (Pseudotsuga menziesii) n...

  1. Transcription Through The Eye Of A Needle: Daily And Annual Cycles Of Gene Expression Variation In Douglas-Fir Needles

    OpenAIRE

    Dolan, Peter; Cronn, Richard; Denver, Dee; Clair, J.; Neale, David; Wegrzyn, Jill; Jogdeo, Sanjuro

    2017-01-01

    Background: Perennial growth in plants is the product of interdependent cycles of daily and annual stimuli that induce cycles of growth and dormancy. In conifers, needles are the key perennial organ that integrates daily and seasonal signals from light, temperature, and water availability. To understand the relationship between seasonal rhythms and seasonal gene expression responses in conifers, we examined diurnal and circannual needle mRNA accumulation in Douglas-fir (Pseudotsuga menziesii)...

  2. Improving Distress in Dialysis (iDiD): A tailored CBT self-management treatment for patients undergoing dialysis.

    Science.gov (United States)

    Hudson, Joanna L; Moss-Morris, Rona; Game, David; Carroll, Amy; Chilcot, Joseph

    2016-12-01

    There is significant psychological distress in adults with end-stage kidney disease (ESKD). However, psychological treatments tailored to address the unique challenges of kidney failure are absent. We identified psychological correlates of distress in ESKD to develop a cognitive-behavioural therapy (CBT) treatment protocol that integrates the mental health needs of patients alongside their illness self-management demands. Studies which examined relationships between distress and psychological factors that apply in the context of ESKD including: health threats, cognitive illness representations and illness management behaviours were narratively reviewed. Review findings were translated into a CBT formulation model to inform the content of a renal-specific seven session CBT treatment protocol, which was commented on and refined by patient representatives. Health threats related to distress were grouped into four themes including: acute ESKD events, loss of role, uncertainty and illness self-management. Having pessimistic illness and treatment perceptions were associated with elevated distress. Non-adherence and avoidance behaviours were related to feelings of distress, whereas cognitive reappraisal, acceptance, social support and assertiveness were associated with less distress. The dialysis-specific CBT formulation identifies the importance of targeting ESKD-specific correlates of distress to allow the delivery of integrated mental and physical health care. The 'Improving Distress in Dialysis (iDiD)' treatment protocol now requires further evaluation in terms of content, feasibility and potential efficacy. © 2016 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  3. Physical function was related to mortality in patients with chronic kidney disease and dialysis.

    Science.gov (United States)

    Morishita, Shinichiro; Tsubaki, Atsuhiro; Shirai, Nobuyuki

    2017-10-01

    Previous studies have shown that exercise improves aerobic capacity, muscular functioning, cardiovascular function, walking capacity, and health-related quality of life (QOL) in patients with chronic kidney disease (CKD) and dialysis. Recently, additional studies have shown that higher physical activity contributes to survival and decreased mortality as well as physical function and QOL in patients with CKD and dialysis. Herein, we review the evidence that physical function and physical activity play an important role in mortality for patients with CKD and dialysis. During November 2016, Medline and Web of Science databases were searched for published English medical reports (without a time limit) using the terms "CKD" or "dialysis" and "mortality" in conjunction with "exercise capacity," "muscle strength," "activities of daily living (ADL)," "physical activity," and "exercise." Numerous studies suggest that higher exercise capacity, muscle strength, ADL, and physical activity contribute to lower mortality in patients with CKD and dialysis. Physical function is associated with mortality in patients with CKD and dialysis. Increasing physical function may decrease the mortality rate of patients with CKD and dialysis. Physicians and medical staff should recognize the importance of physical function in CKD and dialysis. In addition, exercise is associated with reduced mortality among patients with CKD and dialysis. © 2017 International Society for Hemodialysis.

  4. Understanding health decisions using critical realism: home-dialysis decision-making during chronic kidney disease.

    Science.gov (United States)

    Harwood, Lori; Clark, Alexander M

    2012-03-01

    Understanding health decisions using critical realism: home-dialysis decision-making during chronic kidney disease This paper examines home-dialysis decision making in people with Chronic Kidney Disease (CKD) from the perspective of critical realism. CKD programmes focus on patient education for self-management to delay the progression of kidney disease and the preparation and support for renal replacement therapy e.g.) dialysis and transplantation. Home-dialysis has clear health, societal and economic benefits yet service usage is low despite efforts to realign resources and educate individuals. Current research on the determinants of modality selection is superficial and insufficient to capture the complexities embedded in the process of dialysis modality selection. Predictors of home-dialysis selection and the effect of chronic kidney disease educational programmes provide a limited explanation of this experience. A re-conceptualization of the problem is required in order to fully understand this process. The epistemology and ontology of critical realism guides our knowledge and methodology particularly suited for examination of these complexities. This approach examines the deeper mechanisms and wider determinants associated with modality decision making, specifically who chooses home dialysis and under what circumstances. Until more is known regarding dialysis modality decision making service usage of home dialysis will remain low as interventions will be based on inadequate epistemology. © 2011 Blackwell Publishing Ltd.

  5. Design Concept of Dialyzer Biomaterials: How to Find Biocompatible Polymers Based on the Biointerfacial Water Structure.

    Science.gov (United States)

    Tanaka, Masaru

    2017-01-01

    Although various types of materials have been used widely in dialyzers, most biomaterials lack the desired functional properties to interface with blood and have not been engineered for optimum performance. Therefore, there is increasing demand to develop novel materials to address such problems in the dialysis arena. Numerous parameters of polymeric biomaterials can affect biocompatibility in a controlled manner. The mechanisms responsible for the biocompatibility of polymers at the molecular level have not been clearly demonstrated, although many theoretical and experimental efforts have been made to try and understand them. Moreover, water interactions have been recognized as fundamental for the blood response to contact with polymers. We have proposed the 'intermediate water' concept and hypothesized that intermediate water, which prevents the proteins and blood cells from directly contacting the polymer surface, or nonfreezing water on the polymer surface, plays an important role in the biocompatibility of polymers. This chapter provides an overview of the recent experimental progress of biocompatible polymers measured by thermal, spectroscopic, and surface force techniques. Additionally, it highlights recent developments in the use of biocompatible polymeric biomaterials for dialyzers and provides an overview of the progress made in the design of multifunctional biomedical polymers by controlling the biointerfacial water structure through precision polymer synthesis. Key Messages: Intermediate water was found only in hydrated biopolymers (proteins, polysaccharides, and nucleic acids, DNA and RNA) and hydrated biocompatible synthetic polymers. Intermediate water could be one of the main screening factors for the design of appropriate dialyzer materials. © 2017 S. Karger AG, Basel.

  6. The relationship between dialysis adequacy and serum uric acid in dialysis patients; a cross-sectional multi-center study in Iranian hemodialysis centers.

    Science.gov (United States)

    Nemati, Eghlim; Khosravi, Arezoo; Einollahi, Behzad; Meshkati, Mehdi; Taghipour, Mehrdad; Abbaszadeh, Shahin

    2017-01-01

    Introduction: Uric acid is one of the most significant uremic toxins accumulating in chronic renal failure patients treated with standard dialysis. Its clearance has not any exact relation with urea and creatinine clearance. Objectives: The aim of this study was to investigate the relationship between adequacy of dialysis and serum level of uric acid in dialysis patients of some dialysis centers in Iran. Patients and Methods: In this study 1271 hemodialysis patients who have been treated for more than 3 months were evaluated. Their information and examinations from their files in all over the country were gathered and analyzed using SPSS versin18.0. Results: In this study, a significant relationship between dialysis duration and serum level of uric acid was not detected, however, a significant relationship between patients Kt/V and uric acid (R=0.43, P =0.029) was seen. Patients who had higher adequacy of dialysis had a higher level of plasma uric acid. Conclusion: For better controlling of plasma uric acid level of hemodialysis patients, increasing of the adequacy of dialysis or its duration is not effective. Other modalities of decreasing of serum uric acid like, changing diet or lifestyle or medical therapy may be necessary.

  7. Intra-operative navigation of a 3-dimensional needle localization system for precision of irreversible electroporation needles in locally advanced pancreatic cancer.

    Science.gov (United States)

    Bond, L; Schulz, B; VanMeter, T; Martin, R C G

    2017-02-01

    Irreversible electroporation (IRE) uses multiple needles and a series of electrical pulses to create pores in cell membranes and cause cell apoptosis. One of the demands of IRE is the precise needle spacing required. Two-dimensional intraoperative ultrasound (2-D iUS) is currently used to measure inter-needle distances but requires significant expertise. This study evaluates the potential of three-dimensional (3-D) image guidance for placing IRE needles and calculating needle spacing. A prospective clinical evaluation of a 3-D needle localization system (Explorer™) was evaluated in consecutive patients from April 2012 through June 2013 for unresectable pancreatic adenocarcinoma. 3-D reconstructions of patients' anatomy were generated from preoperative CT images, which were aligned to the intraoperative space. Thirty consecutive patients with locally advanced pancreatic cancer were treated with IRE. The needle localization system setup added an average of 6.5 min to each procedure. The 3-D needle localization system increased surgeon confidence and ultimately reduced needle placement time. IRE treatment efficacy is highly dependent on accurate needle spacing. The needle localization system evaluated in this study aims to mitigate these issues by providing the surgeon with additional visualization and data in 3-D. The Explorer™ system provides valuable guidance information and inter-needle distance calculations. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  8. Shape memory polymers

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Thomas S.; Bearinger, Jane P.

    2017-08-29

    New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

  9. Shape memory polymers

    Science.gov (United States)

    Wilson, Thomas S.; Bearinger, Jane P.

    2015-06-09

    New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxyl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

  10. Students as effective harm reductionists and needle exchange organizers.

    Science.gov (United States)

    Barbour, Kyle; McQuade, Miriam; Brown, Brandon

    2017-03-17

    Needle exchange programs are safe, highly effective programs for promoting health among people who inject drugs. However, they remain poorly funded, and often illegal, in many places worldwide due to fear and stigma surrounding drug use. Continued advocacy, education, and implementation of new needle exchanges are thus essential to improve public health and reduce structural inequality. We argue that students, and especially professional and graduate students, have the potential to play an important role in advancing harm reduction. Students benefit from the respect given to the professions they are training to enter, which gives them leverage to navigate the political hurdles often faced by needle exchange organizers, especially in areas that presently lack services. In addition, due to their relative simplicity, needle exchanges do not require much of the licensing, clinical knowledge, and infrastructure associated with more traditional student programs, such as student-run free medical clinics. Students are capable of learning harm reduction cultural approaches and techniques if they remain humble, open-minded, and seek the help of the harm reduction community. Consequently, students can generate tremendous benefits to their community without performing beyond their appropriate clinical limitations. Students benefit from organizing needle exchanges by gaining applied experience in advocacy, organization-building, and political finesse. Working in a needle exchange significantly helps erode stigma against multiple marginalized populations. Students in health-related professions additionally learn clinically-relevant knowledge that is often lacking from their formal training, such as an understanding of structural violence and inequality, root causes of substance use, client-centered approaches to health services, and interacting with clients as peers, rather than through the standard hierarchical medical interaction. We therefore encourage students to learn about

  11. Needle Decompression of Tension Pneumothorax with Colorimetric Capnography.

    Science.gov (United States)

    Naik, Nimesh D; Hernandez, Matthew C; Anderson, Jeff R; Ross, Erika K; Zielinski, Martin D; Aho, Johnathon M

    2017-11-01

    The success of needle decompression for tension pneumothorax is variable, and there are no objective measures assessing effective decompression. Colorimetric capnography, which detects carbon dioxide present within the pleural space, may serve as a simple test to assess effective needle decompression. Three swine underwent traumatically induced tension pneumothorax (standard of care, n = 15; standard of care with needle capnography, n = 15). Needle thoracostomy was performed with an 8-cm angiocatheter. Similarly, decompression was performed with the addition of colorimetric capnography. Subjective operator assessment of decompression was recorded and compared with true decompression, using thoracoscopic visualization for both techniques. Areas under receiver operating curves were calculated and pairwise comparison was performed to assess statistical significance (P pneumothorax, that is, the absence of any pathologic/space-occupying lesion, in 100% of cases (10 of 10 attempts). Standard of care needle decompression was detected by operators in 9 of 15 attempts (60%) and was detected in 3 of 10 attempts when tension pneumothorax was not present (30%). True decompression, under direct visualization with thoracoscopy, occurred 15 of 15 times (100%) with capnography, and 12 of 15 times (80%) without capnography. Areas under receiver operating curves were 0.65 for standard of care and 1.0 for needle capnography (P = .002). Needle decompression with colorimetric capnography provides a rapid, effective, and highly accurate method for eliminating operator bias for tension pneumothorax decompression. This may be useful for the treatment of this life-threatening condition. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  12. Polymer nanocomposites: polymer and particle dynamics

    KAUST Repository

    Kim, Daniel

    2012-01-01

    Polymer nanocomposites containing nanoparticles smaller than the random coil size of their host polymer chains are known to exhibit unique properties, such as lower viscosity and glass transition temperature relative to the neat polymer melt. It has been hypothesized that these unusual properties result from fast diffusion of the nanostructures in the host polymer, which facilitates polymer chain relaxation by constraint release and other processes. In this study, the effects of addition of sterically stabilized inorganic nanoparticles to entangled cis-1,4-polyisoprene and polydimethylsiloxane on the overall rheology of nanocomposites are discussed. In addition, insights about the relaxation of the host polymer chains and transport properties of nanoparticles in entangled polymer nanocomposites are presented. The nanoparticles are found to act as effective plasticizers for their entangled linear hosts, and below a critical, chemistry and molecular-weight dependent particle volume fraction, lead to reduced viscosity, glass transition temperature, number of entanglements, and polymer relaxation time. We also find that the particle motions in the polymer host are hyperdiffusive and at the nanoparticle length scale, the polymer host acts like a simple, ideal fluid and the composites\\' viscosity rises with increasing particle concentration. © 2012 The Royal Society of Chemistry.

  13. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  14. Prevalence and Contents of Advance Directives of Patients with ESRD Receiving Dialysis.

    Science.gov (United States)

    Feely, Molly A; Hildebrandt, Daniel; Edakkanambeth Varayil, Jithinraj; Mueller, Paul S

    2016-12-07

    ESRD requiring dialysis is associated with increased morbidity and mortality rates, including increased rates of cognitive impairment, compared with the general population. About one quarter of patients receiving dialysis choose to discontinue dialysis at the end of life. Advance directives are intended to give providers and surrogates instruction on managing medical decision making, including end of life situations. The prevalence of advance directives is low among patients receiving dialysis. Little is known about the contents of advance directives among these patients with advance directives. We retrospectively reviewed the medical records of all patients receiving maintenance in-center hemodialysis at a tertiary academic medical center between January 1, 2007 and January 1, 2012. We collected demographic data, the prevalence of advance directives, and a content analysis of these advance directives. We specifically examined the advance directives for instructions on management of interventions at end of life, including dialysis. Among 808 patients (mean age of 68.6 years old; men =61.2%), 49% had advance directives, of which only 10.6% mentioned dialysis and only 3% specifically addressed dialysis management at end of life. Patients who had advance directives were more likely to be older (74.5 versus 65.4 years old; Phydration (34.3%), and pain management (43.4%) than dialysis (10.6%). Although one-half of the patients receiving dialysis in our study had advance directives, end of life management of dialysis was rarely addressed. Future research should focus on improving discernment and documentation of end of life values, goals, and preferences, such as dialysis-specific advance directives, among these patients. Copyright © 2016 by the American Society of Nephrology.

  15. Differences in care burden of patients undergoing dialysis in different centres in the netherlands.

    Science.gov (United States)

    de Kleijn, Ria; Uyl-de Groot, Carin; Hagen, Chris; Diepenbroek, Adry; Pasker-de Jong, Pieternel; Ter Wee, Piet

    2017-06-01

    A classification model was developed to simplify planning of personnel at dialysis centres. This model predicted the care burden based on dialysis characteristics. However, patient characteristics and different dialysis centre categories might also influence the amount of care time required. To determine if there is a difference in care burden between different categories of dialysis centres and if specific patient characteristics predict nursing time needed for patient treatment. An observational study. Two hundred and forty-two patients from 12 dialysis centres. In 12 dialysis centres, nurses filled out the classification list per patient and completed a form with patient characteristics. Nephrologists filled out the Charlson Comorbidity Index. Independent observers clocked the time nurses spent on separate steps of the dialysis for each patient. Dialysis centres were categorised into four types. Data were analysed using regression models. In contrast to other dialysis centres, academic centres needed 14 minutes more care time per patient per dialysis treatment than predicted in the classification model. No patient characteristics were found that influenced this difference. The only patient characteristic that predicted the time required was gender, with more time required to treat women. Gender did not affect the difference between measured and predicted care time. Differences in care burden were observed between academic and other centres, with more time required for treatment in academic centres. Contribution of patient characteristics to the time difference was minimal. The only patient characteristics that predicted care time were previous transplantation, which reduced the time required, and gender, with women requiring more care time. © 2017 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  16. Systems Thinking and Leadership: How Nephrologists Can Transform Dialysis Safety to Prevent Infections.

    Science.gov (United States)

    Wong, Leslie P

    2018-04-06

    Infections are the second leading cause of death for patients with ESKD. Despite multiple efforts, nephrologists have been unable to prevent infections in dialysis facilities. The American Society of Nephrology and the Centers for Disease Control and Prevention have partnered to create Nephrologists Transforming Dialysis Safety to promote nephrologist leadership and engagement in efforts to "Target Zero" preventable dialysis infections. Because traditional approaches to infection control and prevention in dialysis facilities have had limited success, Nephrologists Transforming Dialysis Safety is reconceptualizing the problem in the context of the complexity of health care systems and organizational behavior. By identifying different parts of a problem and attempting to understand how these parts interact and produce a result, systems thinking has effectively tackled difficult problems in dynamic settings. The dialysis facility is composed of different physical and human elements that are interconnected and affect not only behavior but also, the existence of a culture of safety that promotes infection prevention. Because dialysis infections result from a complex system of interactions between caregivers, patients, dialysis organizations, and the environment, attempts to address infections by focusing on one element in isolation often fail. Creating a sense of urgency and commitment to eradicating dialysis infections requires leadership and motivational skills. These skills are not taught in the standard nephrology or medical director curriculum. Effective leadership by medical directors and engagement in infection prevention by nephrologists are required to create a culture of safety. It is imperative that nephrologists commit to leadership training and embrace their potential as change agents to prevent infections in dialysis facilities. This paper explores the systemic factors contributing to the ongoing dialysis infection crisis in the United States and the role

  17. [Special penetration needling for refractory peripheral facial paralysis].

    Science.gov (United States)

    Cao, Rongjuan; Qiu, Xiaohu; Xie, Xiaokun

    2018-03-12

    To observe the clinical effect difference between special penetration needling and conventional penetration needling for the refractory peripheral facial paralysis. A total of 97 patients with intractable facial paralysis were randomized into an observation group (49 cases and 2 dropping) and a control group (48 cases and 4 dropping). In the observation group, special penetration needling at an angle about 45° between the penetration needle and paralysis muscle bundle was used, Yangbai (GB 14) through Touwei (ST 8), Yangbai (GB 14) through Shangxing (GV 23), Sizhukong (TE 23) through Yuyao (EX-HN 4), Qianzhen (Extra) through Yingxiang (LI 20), mutual penetration between Yingxiang (LI 20) and Jiache (ST 6). Conventional penetration needling was applied in the control group, Yangbai (GB 14) through Yuyao (EX-HN 4), Cuanzhu (BL 2) through Yuyao (EX-HN 4), mutual penetration between Dicang (ST 4) and Jiache (ST 6), Qianzheng (Extra) through Dicang (ST 4), Sibai (ST 2) through Yingxiang (LI 20). Three groups of electroacupuncture (discontinuous wave, 1 Hz) with tolerance were connected respectively in the two groups, Yangbai (GB 14) and Sizhukong (TE 23), Yangbai (GB 14) and Qianzheng (Extra), Yingxiang (LI 20) and Jiache (ST 6) in the observation group, Yangbai (GB 14) and Cuanzhu (BL 2), Dicang (ST 4) and Jiache (ST 6), Qianzheng (Extra) and Sibai (ST 2) in the control group. TDP was applied in the two groups at the affected Yifeng (TE 17), Jiache (ST 6) and Qianzheng (Extra), which were around the ear. Perpendicular insertion was used at Yifeng (TE 17) at the affected side and Hegu (LI 4) at the healthy side and bilateral Zusanli (ST 36). The needles were retained for 30 min. The treatment was given for 3 courses, once a day and 10 days as a course, 5 days at the interval. House-Brackmann (H-B) facial nerve grading score was recorded before and after treatment. The clinical effects were compared. The H-B scores after treatment in the two groups were higher than

  18. The Hydrodynamics of Needle-Free Intradermal Jet Injection

    Science.gov (United States)

    Simmons, Jonathan; Marston, Jeremy; Fisher, Paul; Broderick, Kate

    2017-11-01

    Needle-free methods of drug delivery circumvent the drawbacks associated with the use of hypodermic needles such as needle-stick injuries, needle-phobia, cross contamination and disposal. Furthermore, pioneering DNA-based vaccines that aim to treat cancer and fight infectious diseases, such as HIV, Ebola and Zika, require precise deposition into the skin to target the immune response producing cells found only in the epidermis and dermis. Intradermal (ID) delivery can be achieved using a needle and the Mantoux technique but this requires a highly skilled technician and so extensive use of DNA vaccines calls for an alternative method of delivery. One option is jet injection which has been employed in mass vaccination programs for intramuscular or subcutaneous delivery and is used by some diabetic patients to inject insulin. In this talk I will present results from our ongoing ex-vivo experimental study into ID jet injection. Ultra-high-speed imaging is used to visualize the process of the jet exiting the nozzle and striking excised skin. A skin bleb grows as liquid is deposited within the skin. I will discuss how the control parameters, such as the rheological profile of the liquid and the stand-off distance, influence the volume of liquid successfully delivered intradermally.

  19. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  20. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  1. MAINTENANCE PLANNING OF THE SEWING NEEDLES OF SIMPLE SEWING MACHINES

    Directory of Open Access Journals (Sweden)

    ŞUTEU Marius Darius

    2017-05-01

    Full Text Available The effectiveness of simple sewing machines can be increased through the planning of predictive maintenance activities. The monitoring of the technical condition of the sewing needles of simple sewing machines was based on the measurement of their noise level. For this purpose a Center 322 sonometer was used, while the data obtained during the monitoring process was analyzed through the E322 software. The working speed of the simple sewing machine that was used for obtaining the experimental results varied from 200 stitches/minute to 4000 stitches/minute. The noise levels of a new needle at the working speed of 200 stitches/minute and 4000 stitches/minute were measured. The noise levels for a fault needle at the same working speed of 200 stitches/minute, respectively 4000 stitches/minute were also measured. Using Fuzzy Logic Toolbox ™ module of Matlab®, a decision-making system for determining when replacement of the sewing needles of simple sewing machines should be performed was developed. A case study illustrates the employment of the decision-making system based on fuzzy logic for a simple sewing machine. By replacing the sewing needles of simple sewing machines at the time specified through the decision-making system based on fuzzy logic, the occurrence of the failure can be prevented and the quality of textile products can be improved.

  2. Serum phosphorus reduction in dialysis patients treated with cinacalcet for secondary hyperparathyroidism results mainly from parathyroid hormone reduction

    DEFF Research Database (Denmark)

    Zitt, Emanuel; Fouque, Denis; Jacobson, Stefan H

    2013-01-01

    The calcimimetic cinacalcet lowers parathyroid hormone (PTH), calcium (Ca) and phosphorus (P) in dialysis patients with secondary hyperparathyroidism (SHPT). We explored serum P changes in dialysis patients treated with cinacalcet, while controlling for vitamin D sterol and phosphate binder (PB...

  3. Comparing Mortality of Peritoneal and Hemodialysis Patients in the First 2 Years of Dialysis Therapy: A Marginal Structural Model Analysis

    NARCIS (Netherlands)

    Lukowsky, Lilia R.; Mehrotra, Rajnish; Kheifets, Leeka; Arah, Onyebuchi A.; Nissenson, Allen R.; Kalantar-Zadeh, Kamyar

    2013-01-01

    Background and objectives There are conflicting research results about the survival differences between hemodialysis and peritoneal dialysis, especially during the first 2 years of dialysis treatment. Given the challenges of conducting randomized trials, differential rates of modality switch and

  4. Nephrologists' perceptions regarding dialysis withdrawal and palliative care in Europe: lessons from a European Renal Best Practice survey

    NARCIS (Netherlands)

    van Biesen, Wim; van de Luijtgaarden, Moniek W. M.; Brown, Edwina A.; Michel, Jean-Pierre; van Munster, Barbara C.; Jager, Kitty J.; van der Veer, Sabine N.

    2015-01-01

    Background. There is a variation in dialysis withdrawal rates, but reasons for this variation across European countries are largely unknown. We therefore surveyed nephrologists' perceptions of factors concerning dialysis withdrawal and palliative care and explored relationships between these

  5. Cardiovascular risk factors in hemodialysis and peritoneal dialysis patients

    Directory of Open Access Journals (Sweden)

    Helal Imed

    2010-01-01

    Full Text Available Cardiovascular diseases are a major cause of morbidity and mortality in patients with end-stage renal disease (ESRD. The aim of our investigation was the evaluation of an extensive cardiovascular profile in hemodialysis (HD and peritoneal dialysis (PD patients. We studied 74 patients with ESRD (38 males, 36 females, maintained either on chronic HD (n= 50 or chronic PD (n= 24 and age and sex matched 20 healthy subjects as controls. The lipid profile, homo-cysteine (Hcy and C reactive protein (CRP were measured. When compared to a healthy popu-lation, HD patients displayed a marked atherogenic profile, as attested by increased levels of total cholesterol (TC, triglycerides (TG, low-density lipoprotein-cholesterol (LDL-C, apolipoprotein A (Apo A, CRP, Hcy and lower concentrations of high-density lipoprotein-cholesterol (HDL-C, Apo B, albumin (ALB. A significant difference was noted concerning the rates of Apo B, HDL-C, TC, ALB and Hcy. Same biological disorders that those found at HD patients were noted in these PD patients. One also noted lower concentration in Apo A. there were a significant diffe-rence with the reference group concerning the rates of albumin, Apo A, HDL-Cl and Hcy. When compared to PD patients, HD patients had significantly decreased concentration of LDL-C. The peculiar metabolic changes observed in the present study confirm the marked tendency of patients with impaired renal function for developing cardiovascular diseases, irrespectively of the type of dialysis. We suggest including uremia-related risk factors in the panel for evaluation of cardio-vascular risk in dialysis patients.

  6. Setting research priorities for patients on or nearing dialysis.

    Science.gov (United States)

    Manns, Braden; Hemmelgarn, Brenda; Lillie, Erin; Dip, Sally Crowe P G; Cyr, Annette; Gladish, Michael; Large, Claire; Silverman, Howard; Toth, Brenda; Wolfs, Wim; Laupacis, Andreas

    2014-10-07

    With increasing emphasis among health care providers and funders on patient-centered care, it follows that patients and their caregivers should be included when priorities for research are being established. This study sought to identify the most important unanswered questions about the management of kidney failure from the perspective of adult patients on or nearing dialysis, their caregivers, and the health care professionals who care for these patients. Research uncertainties were identified through a national Canadian survey of adult patients on or nearing dialysis, their caregivers, and health care professionals. Uncertainties were refined by a steering committee that included patients, caregivers, researchers, and clinicians to assemble a short-list of the top 30 uncertainties. Thirty-four people (11 patients; five caregivers; eight physicians; six nurses; and one social worker, pharmacist, physiotherapist, and dietitian each) from across Canada subsequently participated in a workshop to determine the top 10 research questions. In total, 1570 usable research uncertainties were received from 317 respondents to the survey. Among these, 259 unique uncertainties were identified; after ranking, these were reduced to a short-list of 30 uncertainties. During the in-person workshop, the top 10 research uncertainties were identified, which included questions about enhanced communication among patients and providers, dialysis modality options, itching, access to kidney transplantation, heart health, dietary restrictions, depression, and vascular access. These can be used alongside the results of other research priority-setting exercises to guide researchers in designing future studies and inform health care funders. Copyright © 2014 by the American Society of Nephrology.

  7. Mechanisms of acid-base regulation in peritoneal dialysis.

    Science.gov (United States)

    Sow, Amadou; Morelle, Johann; Hautem, Nicolas; Bettoni, Carla; Wagner, Carsten A; Devuyst, Olivier

    2017-11-22

    Peritoneal dialysis (PD) contributes to restore acid-base homeostasis in patients with end-stage renal disease. The transport pathways for buffers and carbon dioxide (CO2) across the peritoneal membrane remain poorly understood. Combining well-established PD protocols, whole-body plethysmography and renal function studies in mice, we investigated molecular mechanisms of acid-base regulation in PD, including the potential role of the water channel aquaporin-1 (AQP1). After instillation in peritoneal cavity, the pH of acidic dialysis solutions increased within minutes to rapidly equilibrate with blood pH, whereas the neutral pH of biocompatible solutions remained constant. Predictions from the three-pore model of peritoneal transport suggested that local production of HCO3- accounts at least in part for the changes in intraperitoneal pH observed with acidic solutions. Carbonic anhydrase (CA) isoforms were evidenced in the peritoneal membrane and their inhibition with acetazolamide significantly decreased local production of HCO3- and delayed changes in intraperitoneal pH. On the contrary, genetic deletion of AQP1 had no effect on peritoneal transport of buffers and diffusion of CO2. Besides intraperitoneal modifications, the use of acidic dialysis solutions enhanced acid excretion both at pulmonary and renal levels. These findings suggest that changes in intraperitoneal pH during PD are mediated by bidirectional buffer transport and by CA-mediated production of HCO3- in the membrane. The use of acidic solutions enhances acid excretion through respiratory and renal responses, which should be considered in patients with renal failure. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  8. The elderly on dialysis: some considerations in compliance.

    Science.gov (United States)

    McKevitt, P M; Jones, J F; Lane, D A; Marion, R R

    1990-10-01

    Compliance with scheduled treatments, dietary and fluid restrictions, and multiple medications is an important component in the care and well-being of end-stage renal disease (ESRD) patients. Given the rigorus and complex demands of dialysis, it is important to examine the issue of compliance, focusing on a large and ever-increasing segment of our patient population, the elderly. The ESRD literature reflects efforts to define and measure levels of compliance, identify factors that influence and predict compliance, and develop intervention strategies to improve adherence to treatment regimens. While limited attention has been focused specifically on the elderly, there are studies suggesting that age may be a factor associated with improved adherence and that social support may be a significant contributor to compliance in this patient group. In an effort to examine the current status and needs of the dialysis elderly, research is in progress at Chromalloy American Kidney Center, Washington University, which replicates a study of 5 years ago. Eighty-four patients age 60 and over, on dialysis for a minimum of 6 months, were identified. Sociodemographic, treatment, compliance, and functional capacity data were collected; additional mental and psychological testing was completed on patients willing and able to participate. Preliminary data suggest the current elderly population is larger and significantly older than that of 5 years ago. Other sociodemographic data indicate the population is increasingly female, black, and more socioeconomically disadvantaged. In regard to compliance, the vast majority of elderly demonstrate good compliance as measured by serum potassium, fair to good compliance with phosphorus, and fair to poor compliance with fluid restrictions.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. NPIP: A skew line needle configuration optimization system for HDR brachytherapy

    International Nuclear Information System (INIS)

    Siauw, Timmy; Cunha, Adam; Berenson, Dmitry; Atamtürk, Alper; Hsu, I-Chow; Goldberg, Ken; Pouliot, Jean

    2012-01-01

    Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, δ. The candidate needle set consisted of 5000 needles, and a range of δ values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of δ values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer

  10. Peritoneal membrane characteristics in patients on peritoneal dialysis

    Directory of Open Access Journals (Sweden)

    Jamal Al-wakeel

    2011-01-01

    Full Text Available Peritoneal dialysis (PD is a well-established modality for treatment of patients with end-stage renal disease, giving excellent patient and technique survival rates. In Saudi Arabia, data collected by the Saudi Center for Organ Transplantation showed that in 2008, patients on PD accounted for a mere 4.8% of total patients on renal replacement therapy, including hemodialysis and renal transplantation. This study was conducted to identify the characteristics of membrane per-meability in the Saudi population and to assess the role of various factors affecting solute transport across the peritoneal membrane. We followed up a total of 52 patients on Continuous Ambulatory Peritoneal Dialysis (CAPD as well as Automated Peritoneal Dialysis (APD, being treated in the PD unit of the King Khalid University Hospital, Riyadh. There were 30 female and 22 male patients; 14 patients were using CAPD while 38 patients were on APD. The mean age of the patients was 50.5 years, with a range of 14-86 years. The average body mass index (BMI was 27.1 kg/m 2 and the mean body surface area (BSA of the study patients was 1.71 m 2 . A standardized PET test was performed on all patients, 4-6 weeks after initiation of regular PD. The Kt/V and creatinine clearance measured 6-8 weeks after initiation of dialysis were 1.96 and 56.59 L/week, respectively. Residual renal function was assessed on the basis of daily urine output, using 24-hour urine collection. The mean serum urea con-centration was 16.91 mmol/L and mean serum creatinine was 702 μmol/L. According to the Peritoneal Equiliberation Test (PET, 8% of the subjects belonged to the high trans-porter category, 44% patients belonged to the high-average transport group, 46% to the low-average category and 2% came in the low transporter category. Our study suggests that the patient characteristics and demographic para-meters seen in the Saudi population are comparable to those seen in other studies from the Middle East and

  11. Metformin-associated lactic acidosis in a peritoneal dialysis patient

    Directory of Open Access Journals (Sweden)

    Najlaa Almaleki

    2015-01-01

    Full Text Available Metformin is one of the commonly used drugs in type-2 diabetes mellitus. It reduces glucose levels by increasing insulin sensitivity, reducing hepatic glucose release and increasing muscle uptake. One of the serious complications associated with metformin use is lactic acidosis, and it is associated with high morbidity and mortality. This is more likely to happen in patients with renal failure due to reduced clearance. International guidelines recommend discontinuing metformin in advanced renal failure. We report a case of metformin-associated lactic acidosis in a patient with end-stage renal disease on peritoneal dialysis. The patient presented with severe lactic acidosis, which was successfully treated with hemodialysis.

  12. The Association between Peritoneal Dialysis Modality and Peritonitis

    Science.gov (United States)

    Johnson, David W.; McDonald, Stephen P.; Boudville, Neil; Borlace, Monique; Badve, Sunil V.; Sud, Kamal; Clayton, Philip A.

    2014-01-01

    Background and objectives There is conflicting evidence comparing peritonitis rates among patients treated with continuous ambulatory peritoneal dialysis (CAPD) or automated peritoneal dialysis (APD). This study aims to clarify the relationship between peritoneal dialysis (PD) modality (APD versus CAPD) and the risk of developing PD-associated peritonitis. Design, setting, participants, & measurements This study examined the association between PD modality (APD versus CAPD) and the risks, microbiology, and clinical outcomes of PD-associated peritonitis in 6959 incident Australian PD patients between October 1, 2003, and December 31, 2011, using data from the Australia and New Zealand Dialysis and Transplant Registry. Median follow-up time was 1.9 years. Results Patients receiving APD were younger (60 versus 64 years) and had fewer comorbidities. There was no association between PD modality and time to first peritonitis episode (adjusted hazard ratio [HR] for APD versus CAPD, 0.98; 95% confidence interval [95% CI], 0.91 to 1.07; P=0.71). However, there was a lower hazard of developing Gram-positive peritonitis with APD than CAPD, which reached borderline significance (HR, 0.90; 95% CI, 0.80 to 1.00; P=0.05). No statistically significant difference was found in the risk of hospitalizations (odds ratio, 1.12; 95% CI, 0.93 to 1.35; P=0.22), but there was a nonsignificant higher likelihood of 30-day mortality (odds ratio, 1.33; 95% CI, 0.93 to 1.88; P=0.11) at the time of the first episode of peritonitis for patients receiving APD. For all peritonitis episodes (including subsequent episodes of peritonitis), APD was associated with lower rates of culture-negative peritonitis (incidence rate ratio [IRR], 0.81; 95% CI, 0.69 to 0.94; P=0.002) and higher rates of gram-negative peritonitis (IRR, 1.28; 95% CI, 1.13 to 1.46; P=0.01). Conclusions PD modality was not associated with a higher likelihood of developing peritonitis. However, APD was associated with a borderline

  13. Perceived illness intrusions among continuous ambulatory peritoneal dialysis patients

    Directory of Open Access Journals (Sweden)

    Usha Bapat

    2012-01-01

    Full Text Available To study the perceived illness intrusion of continuous ambulatory peritoneal dialysis (CAPD patients, to examine their demographics, and to find out the association among demographics, duration of illness as well as illness intrusion, 40 chronic kidney disease stage V patients on CAPD during 2006-2007 were studied. Inclusion criteria were patients′ above 18 years, willing, stable, and completed at least two months of dialysis. Those with psychiatric co-morbidity were excluded. Sociodemographics were collected using a semi-structured interview schedule. A 14-item illness intrusion checklist covering various aspects of life was administered. The subjects had to rate the illness intrusion in their daily life and the extent of intrusion. The data was analyzed using descriptive statistics and chi square test of association. The mean age of the subjects was 56.05 ± 10.05 years. There was near equal distribution of gender. 82.5% were married, 70.0% belonged to Hindu religion, 45.0% were pre-degree, 25.0% were employed, 37.5% were housewives and 30.0% had retired. 77.5% belonged to the upper socioeconomic strata, 95.0% were from an urban background and 65.0% were from nuclear families. The mean duration of dialysis was 19.0 ± 16.49 months. Fifty-eight percent of the respondents were performing the dialysis exchanges by themselves. More than 95.0%were on three or four exchanges per day. All the 40 subjects reported illness intrusion in their daily life. Intrusion was perceived to some extent in the following areas: health 47.5%, work 25.0%, finance 37.5%, diet 40.0%, and psychological 50.0%. Illness had not intruded in the areas of relationship with spouse 52.5%, sexual life 30.0%, with friends 92.5%, with family 85.5%, social functions 52.5%, and religious functions 75.0%. Statistically significant association was not noted between illness intrusion and other variables. CAPD patients perceived illness intrusion to some extent in their daily life

  14. Clinical Causes of Inflammation in Peritoneal Dialysis Patients

    Directory of Open Access Journals (Sweden)

    Yeoungjee Cho

    2014-01-01

    Full Text Available Inflammation at both systemic and local intraperitoneal levels commonly affects peritoneal dialysis (PD patients. Interest in inflammatory markers as targets of therapeutic intervention has been considerable as they are recognised as predictors of poor clinical outcomes. However, prior to embarking on strategies to reduce inflammatory burden, it is of paramount importance to define the underlying processes that drive the chronic active inflammatory status. The present review aims to comprehensively describe clinical causes of inflammation in PD patients to which potential future strategies may be targeted.

  15. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  16. The energy cost of kidney proton dialysis in sickle cell anaemia

    African Journals Online (AJOL)

    AJB SERVER

    2007-01-18

    Jan 18, 2007 ... kidney as most of the energy for proton dialysis is wasted as a result of high entropy. Key words: Sickle cell, anaemia, energy, kidney, dialysis, proton, and enthalpy. INTRODUCTION. Evidence exists that for those with sickle cell syndromes. “kidney damage starts very early and progresses throu- ghout life” ...

  17. Membrane biocompatibility does not affect whole body protein metabolism during dialysis

    NARCIS (Netherlands)

    Veeneman, JM; Kingma, HA; Stellaard, F; de Jong, PE; Reijngoud, DJ; Huisman, RM

    2005-01-01

    Background: Protein-calorie malnutrition is present in 30-50% of dialysis patients. The lack of biocompatibility of the dialysis membrane, which results in low-grade inflammation, could be responsible for this malnutrition. We investigated whether protein-energy malnutrition could be partly due to

  18. Dialysis adequacy and necessity of implement health education models to its promotion in Iran

    Directory of Open Access Journals (Sweden)

    Hossein Esmaili

    2016-10-01

    Full Text Available The prevalence and incidence of Chronic Renal Failure [CRF] is increasing in the world. The main way for treatment of End-Stage Kidney Disease [ESKD] - that leads from CRF - is hemodialysis. One of the most important criteria for the evaluation of hemodialysis treatment process is the measure of dialysis adequacy. Dialysis adequacy is considered to the best therapeutic indicator for patient's clinical results and the best index for the assessment of the dialysis adequacy is the urea clearance. Although adherence accurate diet by patients is complement for hemodialysis and it is recommended for effectively control of symptoms of uremic syndrome and preventing longterm complications, many of these patients do not keep diet and fluid restriction and result in non-adequate dialysis, therefore, in order to improve dialysis adequacy, education, justify and emend patient’s attitude about diet necessity of following dialysis period times precisely and on time refers are very important. Due to the complexity of the treatment and care of hemodialysis patients, as well as the needs for adequate dialysis implement for to achieve effective treatment for these patients, by designing and run an educational program based on Health Education Models, dialysis adequacy can be improved.

  19. 78 FR 51276 - Proposed Information Collection (Access to Care Dialysis Pilot Survey and Interview); Activity...

    Science.gov (United States)

    2013-08-20

    ... to Care Dialysis Pilot Survey and Interview); Activity: Comment Request AGENCY: Veterans Health... Care Dialysis Pilot Survey and Interview)'' in any correspondence. During the comment period, comments... and Interview, VA Form 10-10067. a. Access to Care Questionnaire, VA Form 10-10067. b. Access to Care...

  20. Characteristics and outcomes among patients with need for early dialysis after lung transplantation surgery.

    Science.gov (United States)

    Banga, Amit; Mohanka, Manish; Mullins, Jessica; Bollineni, Srinivas; Kaza, Vaidehi; Tanriover, Bekir; Torres, Fernando

    2017-11-01

    With the introduction of lung allocation score (LAS), increasingly sicker patients are undergoing lung transplantation (LT). This study was conducted to determine the time trends in need for dialysis after LT, identify variables independently associated with need for dialysis, and evaluate its association with 1- and 5-year mortality. We queried the United Network of Organ Sharing database for adult patients undergoing LT between 1994 and 2014. We excluded patients with simultaneous dual organ transplantation and where data regarding the need for dialysis were not available. Time trends in the yearly incidence of the need for dialysis showed a gradual increase (P = .012). In the post-LAS era, ethnicity, underlying diagnosis, estimated GFR 35 mm Hg, ventilator or extracorporeal membrane oxygenation support at LT, and >20% increase in serum creatinine between listing and match were independently associated with the need for dialysis. Patients with need for dialysis had significantly increased hazard of 1-year (n = 13 849; adjusted hazard ratio, 95% CI:7.23, 6.2-8.4, P need for early dialysis after LT, and these patients have significantly worse early and late survival. Several pre-transplant recipient characteristics are independently associated with the need for dialysis. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Lactic Acid Recovery in Electro-Enhanced Dialysis: Modelling and Validation

    DEFF Research Database (Denmark)

    Prado Rubio, Oscar Andres; Jørgensen, Sten Bay; Jonsson, Gunnar Eigil

    2009-01-01

    and migration across the boundary layers and membranes. The model is validated for Donnan dialysis recovery of different monoprotic carboxylic acids. Simulations are used to evaluate the potential enhancement of lactate fluxes under current load conditions, referred as Electro-Enhanced Dialysis operation...

  2. Characteristics in nutritional status of patients on dialysis in south korea

    Directory of Open Access Journals (Sweden)

    Jonghyo Lee

    2012-06-01

    In conclusion, specialized nutrition education depending on dialytic modality should be necessary to efficiently improve nutritional status, and it can be postulated that essential amino acid and other supplement are helpful for improving nutritional status in dialysis patients, especially in peritoneal dialysis patients

  3. Patients in assisted automated peritoneal dialysis develop strategies for self-care

    DEFF Research Database (Denmark)

    Holch, Kirsten

    2008-01-01

      Background Since 2000, a model for Assisted Automated Peritoneal Dialysis (aAPD) for patients in their own home needing chronic dialysis treatment has been developed at Aarhus University Hospital, Skejby, Denmark. The patient group consists of physically or mentally frail elderly who cannot...

  4. Transdiaphragmatic peritoneal hernia complicating peritoneal dialysis: demonstration with spiral computed tomography peritoneography and peritoneal scintigraphy

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Lonneux, Max; Goffin, Eric

    2005-01-01

    The authors describe a rare case of peritoneal transdiaphragmatic hernia discovered immediately after a car accident in a young male patient on peritoneal dialysis. The potential role of CT peritoneography and peritoneal scintigraphy to demonstrate and understand thoracic complications of ambulatory peritoneal dialysis is discussed. (orig.)

  5. The Natural Time Course of Membrane Alterations During Peritoneal Dialysis Is Partly Altered by Peritonitis

    NARCIS (Netherlands)

    van Esch, Sadie; Struijk, Dirk G.; Krediet, Raymond T.

    2016-01-01

    ♦ The quality of the peritoneal membrane can deteriorate over time. Exposure to glucose-based dialysis solutions is the most likely culprit. Because peritonitis is a common complication of peritoneal dialysis (PD), distinguishing between the effect of glucose exposure and a possible additive effect

  6. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: A study protocol

    NARCIS (Netherlands)

    S.M. Hagen (Sander); A.M. van Alphen (Adriaan); J.N.M. IJzermans (Jan); F.J.M.F. Dor (Frank)

    2011-01-01

    textabstractBackground: Peritoneal dialysis (PD) is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as

  7. Challenges of Undergoing Dialysis With Emphasis on Aging Syndromes in the Elderly

    Directory of Open Access Journals (Sweden)

    Ehterm Sadat Ilali

    2017-03-01

    Conclusion The number of elderly people undergoing dialysis has increased, and it seems that we need to know more about the problems of this age group. With the increasing awareness and knowledge about these problems, we can plan prevention, care, and rehabilitation programs for the elderly people with dialysis.

  8. Is the decline of renal function different before and after the start of dialysis?

    NARCIS (Netherlands)

    de Jager, Dinanda J.; Halbesma, Nynke; Krediet, Raymond T.; Boeschoten, Elisabeth W.; le Cessie, Saskia; Dekker, Friedo W.; Grootendorst, Diana C.; Apperloo, A. J.; Bijlsma, J. A.; Boekhout, M.; Boer, W. H.; van der Boog, P. J. M.; Büller, H. R.; van Buren, M.; de Charro, F. Th; Doorenbos, C. J.; van den Dorpel, M. A.; van Es, A.; Fagel, W. J.; Feith, G. W.; de Fijter, C. W. H.; Frenken, L. A. M.; van Geelen, J. A. C. A.; Gerlag, P. G. G.; Grave, W.; Gorgels, J. P. M. C.; Huisman, R. M.; Jager, K. J.; Jie, K.; Koning-Mulder, W. A. H.; Koolen, M. I.; Hovinga, T. K. Kremer; Lavrijssen, A. T. J.; Luik, A. J.; van der Meulen, J.; Parlevliet, K. J.; Raasveld, M. H. M.; van der Sande, F. M.; Schonck, M. J. M.; Schuurmans, M. M. J.; Siegert, C. E. H.; Stegeman, C. A.; Stevens, P.; Thijssen, J. G. P.; Valentijn, R. M.; Vastenburg, G. H.; Verburgh, C. A.; Vincent, H. H.; Vos, P. F.

    2013-01-01

    The presence of glomerular filtration in dialysis patients is associated with improved survival and quality of life. This study explores the time course of the glomerular filtration rate (GFR) between 1 year before and 1 year after the start of haemodialysis (HD) and peritoneal dialysis (PD). This

  9. Addressing the burden of dialysis around the world: A summary of the roundtable discussion on dialysis economics at the First International Congress of Chinese Nephrologists 2015.

    Science.gov (United States)

    Li, Philip Kam-Tao; Lui, Sing Leung; Ng, Jack Kit-Chung; Cai, Guan Yan; Chan, Christopher T; Chen, Hung Chun; Cheung, Alfred K; Choi, Koon Shing; Choong, Hui Lin; Fan, Stanley L; Ong, Loke Meng; Yu, Linda Wai Ling; Yu, Xue Qing

    2017-12-01

    To address the issue of heavy dialysis burden due to the rising prevalence of end-stage renal disease around the world, a roundtable discussion on the sustainability of managing dialysis burden around the world was held in Hong Kong during the First International Congress of Chinese Nephrologists in December 2015. The roundtable discussion was attended by experts from Hong Kong, China, Canada, England, Malaysia, Singapore, Taiwan and United States. Potential solutions to cope with the heavy burden on dialysis include the prevention and retardation of the progression of CKD; wider use of home-based dialysis therapy, particularly PD; promotion of kidney transplantation; and the use of renal palliative care service. © 2017 Asian Pacific Society of Nephrology.

  10. Cognitive Impairment in Non-Dialysis-Dependent CKD and the Transition to Dialysis: Findings From the Chronic Renal Insufficiency Cohort (CRIC) Study.

    Science.gov (United States)

    Harhay, Meera N; Xie, Dawei; Zhang, Xiaoming; Hsu, Chi-Yuan; Vittinghoff, Eric; Go, Alan S; Sozio, Stephen M; Blumenthal, Jacob; Seliger, Stephen; Chen, Jing; Deo, Rajat; Dobre, Mirela; Akkina, Sanjeev; Reese, Peter P; Lash, James P; Yaffe, Kristine; Tamura, Manjula Kurella

    2018-05-02

    Advanced chronic kidney disease is associated with elevated risk for cognitive impairment. However, it is not known whether and how cognitive impairment is associated with planning and preparation for end-stage renal disease. Retrospective observational study. 630 adults participating in the CRIC (Chronic Renal Insufficiency Cohort) Study who had cognitive assessments in late-stage CKD, defined as estimated glome-rular filtration rate ≤ 20mL/min/1.73m 2 , and subsequently initiated maintenance dialysis therapy. Predialysis cognitive impairment, defined as a score on the Modified Mini-Mental State Examination lower than previously derived age-based threshold scores. Covariates included age, race/ethnicity, educational attainment, comorbid conditions, and health literacy. Peritoneal dialysis (PD) as first dialysis modality, preemptive permanent access placement, venous catheter avoidance at dialysis therapy initiation, and preemptive wait-listing for a kidney transplant. Multivariable-adjusted logistic regression. Predialysis cognitive impairment was present in 117 (19%) participants. PD was the first dialysis modality among 16% of participants (n=100), 75% had preemptive access placed (n=473), 45% avoided using a venous catheter at dialysis therapy initiation (n=279), and 20% were preemptively wait-listed (n=126). Predialysis cognitive impairment was independently associated with 78% lower odds of PD as the first dialysis modality (adjusted OR [aOR], 0.22; 95% CI, 0.06-0.74; P=0.02) and 42% lower odds of venous catheter avoidance at dialysis therapy initiation (aOR, 0.58; 95% CI, 0.34-0.98; P=0.04). Predialysis cognitive impairment was not independently associated with preemptive permanent access placement or wait-listing. Potential unmeasured confounders; single measure of cognitive function. Predialysis cognitive impairment is associated with a lower likelihood of PD as a first dialysis modality and of venous catheter avoidance at dialysis therapy

  11. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  12. Effects of percutaneous needle liver biopsy on dairy cow behaviour

    DEFF Research Database (Denmark)

    Mølgaard, Lene; Damgaard, Birthe Marie; Bjerre-Harpøth, Vibeke

    2012-01-01

    In cattle, percutaneous needle liver biopsy is used for scientific examination of liver metabolism. The impact of the biopsy procedure is, however, poorly investigated. Our aim was to examine the behaviour of dairy cows during and after liver biopsy. Data were collected from 18 dry cows....... Percutaneous needle liver biopsies (after administration of local anaesthesia (2% Procaine)) and blood samples were taken during restraining. During the control treatment, animals were restrained and blood sampled. During the biopsy procedure, cows showed increased restlessness (P = 0.008), frequency of head...... behavioural changes for up to 19 h – and particularly for behaviour previously associated with pain. Even though the exact welfare impact of percutaneous needle liver biopsies in cows is not known, and the magnitude of the behavioural changes was limited, pain always has negative effects on animal welfare...

  13. Understanding the physiology of postharvest needle abscission in balsam fir

    Directory of Open Access Journals (Sweden)

    Mason Thane Macdonald

    2015-11-01

    Full Text Available Balsam fir (Abies balsamea trees are commonly used as a specialty horticultural species for Christmas trees and associated greenery in eastern Canada and United States. Postharvest needle abscission has always been a problem, but is becoming an even bigger challenge in recent years presumably due to increased autumn temperatures and earlier harvesting practices. An increased understanding of postharvest abscission physiology in balsam fir may benefit the Christmas tree industry while simultaneously advancing our knowledge in senescence and abscission of conifers in general. Our paper describes the dynamics of needle abscission in balsam fir while identifying key factors that modify abscission patterns. Concepts such as genotypic abscission resistance, nutrition, environmental factors, and postharvest changes in water conductance and hormone evolution are discussed as they relate to our understanding of the balsam fir abscission physiology. Our paper ultimately proposes a pathway for needle abscission via ethylene and also suggests other potential alternative pathways based on our current understanding.

  14. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  15. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  16. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation.

    Science.gov (United States)

    Limmer, Alexandra M; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  17. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    Directory of Open Access Journals (Sweden)

    Alexandra M. Limmer

    2017-01-01

    Full Text Available Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient’s caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  18. Spruce needles used as radioecological biotracers; Fichtennadeln als radiooekologische Bioindikatoren

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, C.; Gruber, V.; Baumgartner, A. [BOKU - Univ. fuer Bodenkultur Wien (Austria). LLC-Labor Arsenal; Idinger, J. [Technische Univ. Wien (Austria). Atominst.; Fuerst, A. [BFW - Bundesforschungs- und Ausbildungszentrum fuer Wald, Naturgefahren und Landschaft, Wien (Austria). Inst. fuer Waldschutz, Pflanzenanalyse; Maringer, F.J. [BOKU - Univ. fuer Bodenkultur Wien (Austria). LLC-Labor Arsenal; BEV - Bundesamt fuer Eich- und Vermessungswesen, Wien (Austria)

    2009-07-01

    In a two years project spruce needle samples of the Austrian Bioindicator Grid were analysed by gamma-ray spectrometry to investigate the spatial and temporal distribution of radionuclides in spruce needles of the last 25 years with the main focus on the radioactive contamination before and after the Chernobyl fallout 1986. More than 600 spruce needle samples at selected locations of the Bioindicator Grid were analysed for different natural and anthropogenic radionuclides: {sup 137}Cs, {sup 40}K, {sup 210}Pb, {sup 226}Ra, {sup 228}Ra, {sup 238}U. Additionally, soil samples were taken at selected sites to study the soil-to-plant transfer. This radioecological evaluation is an important part of an existing environmental surveillance programme in Upper Austria in order to gain basic information on the impact of environmental changes on the radioecological behaviour of spruce trees. (orig.)

  19. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  20. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)