WorldWideScience

Sample records for pole placement technique

  1. On PID Controller Design by Combining Pole Placement Technique with Symmetrical Optimum Criterion

    Directory of Open Access Journals (Sweden)

    Viorel Nicolau

    2013-01-01

    Full Text Available In this paper, aspects of analytical design of PID controllers are studied, by combining pole placement technique with symmetrical optimum criterion. The proposed method is based on low-order plant model with pure integrator, and it can be used for both fast and slow processes. Starting from the desired closed-loop transfer function, which contains a second-order oscillating system and a lead-lag compensator, it is shown that the zero value depends on the real-pole value of closed-loop transfer function. In addition, there is only one pole value, which satisfies the assumptions of symmetrical optimum criterion imposed to open-loop transfer function. In these conditions, by combining the pole placement technique with symmetrical optimum criterion, the analytical expressions of the controller parameters can be simplified. For simulations, PID autopilot design for heading control problem of a conventional ship is considered.

  2. Tuning of SVC Stabilizers over a Wide Range of Load Parameters Using Pole-Placement Technique

    Directory of Open Access Journals (Sweden)

    K. Ellithy

    2008-12-01

    Full Text Available This paper investigates the effect of typical load model parameters on the static var compensator (SVC stabilizers tuning. A proportional-Integral (PI type stabilizer is considered and its gain-settings are tuned using the pole-placement technique to improve the damping of power systems. Tuning of SVC stabilizers (damping controllers traditionally assumes that the system loads are voltage dependent with fixed parameters. However, the load parameters are generally uncertain. This uncertain behavior of the load parameters can de-tune the gains of the stabilizer; consequently the SVC stabilizer with fixed gain-settings can be adequate for some load parameters but contrarily can reduce system damping and contribute to system instability with loads having other parameters. The effect of typical load model parameters on the tuning gains of the SVC PI stabilizer is examined and it is found the load parameters have a considerable influence on the tuning gains. The time domain simulations performed on the system show that the SVC stabilizer tuned at fixed load parameters reduce the system damping under other load parameters and could lead system instability.

  3. Groebner Basis Solutions to Satellite Trajectory Control by Pole Placement

    Science.gov (United States)

    Kukelova, Z.; Krsek, P.; Smutny, V.; Pajdla, T.

    2013-09-01

    Satellites play an important role, e.g., in telecommunication, navigation and weather monitoring. Controlling their trajectories is an important problem. In [1], an approach to the pole placement for the synthesis of a linear controller has been presented. It leads to solving five polynomial equations in nine unknown elements of the state space matrices of a compensator. This is an underconstrained system and therefore four of the unknown elements need to be considered as free parameters and set to some prior values to obtain a system of five equations in five unknowns. In [1], this system was solved for one chosen set of free parameters with the help of Dixon resultants. In this work, we study and present Groebner basis solutions to this problem of computation of a dynamic compensator for the satellite for different combinations of input free parameters. We show that the Groebner basis method for solving systems of polynomial equations leads to very simple solutions for all combinations of free parameters. These solutions require to perform only the Gauss-Jordan elimination of a small matrix and computation of roots of a single variable polynomial. The maximum degree of this polynomial is not greater than six in general but for most combinations of the input free parameters its degree is even lower. [1] B. Palancz. Application of Dixon resultant to satellite trajectory control by pole placement. Journal of Symbolic Computation, Volume 50, March 2013, Pages 79-99, Elsevier.

  4. From Beale Number to Pole Placement Design of a Free Piston Stirling Engine

    Directory of Open Access Journals (Sweden)

    Zare Shahryar

    2017-12-01

    Full Text Available In this paper, pole placement-based design and analysis of a free piston Stirling engine (FPSE is presented and compared to the well-defined Beale number design technique. First, dynamic and thermodynamic equations governing the engine system are extracted. Then, linear dynamics of the free piston Stirling engine are studied using dynamic systems theory tools such as root locus. Accordingly, the effects of variations of design parameters such as mass of pistons, stiffness of springs, and frictional damping on the locations of dominant closed-loop poles are investigated. The design procedure is thus conducted to place the dominant poles of the dynamic system at desired locations on the s-plane so that the unstable dynamics, which is the required criterion for energy generation, is achieved. Next, the closed-loop poles are selected based on a desired frequency so that a periodical system is found. Consequently, the design parameters, including mass and spring stiffness for both power and displacer pistons, are obtained. Finally, the engine power is calculated through the proposed control-based analysis and the result is compared to those of the experimental work and the Beale number approach. The outcomes of this work clearly reveal the effectiveness of the control-based design technique of FPSEs compared to the well-known approaches such as Beale number.

  5. ADVANCED DENTAL IMPLANT PLACEMENT TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Alex M. GREENBERG

    2017-12-01

    Full Text Available The availability of in office Cone Beam CT (CBCT scanners, dental implant planning software, CAD CAM milling, and rapid printing technologies allow for the precise placement of dental implants and immediate prosthetic temporization. These technologies allow for flapless implant placement, or open flap bone reduction for “All on 4” techniques with improved preoperative planning and intraoperative performance. CBCT permits practitioners in an office setting with powerful diagnostic capabilities for the evaluation of bone quality and quantity, as well as dental and osseous pathology essential for better informed dental implant treatment. CBCT provides the convenience of in office imaging and decreased radiation exposure. Rapid printing technologies provide decreased time and high accuracy for bone model and surgical guide fabrication.

  6. Transcendental and interpolation methods in simultaneous stabilization and simultaneous partial pole placement problems

    Science.gov (United States)

    Ghosh, B. K.

    1986-01-01

    The existence of a compensator which simultaneously renders a given r-tuple of multiinput-multioutput p x m linear dynamical systems internally stable is investigated. In particular, a set of simultaneously stabilizable r-tuples of plants is parametrized, and it is shown that, provided r = max(m,p) or less, the above set is semialgebraic and dense in the space Sigma of r-tuples of plants. An extension of the classical pole placement and stabilization problems is considered, and the simultaneous partial pole placement problem is investigated.

  7. Robust pole placement for second-order systems: an LMI approach

    Czech Academy of Sciences Publication Activity Database

    Henrion, D.; Šebek, Michael; Kučera, Vladimír

    2005-01-01

    Roč. 41, č. 1 (2005), s. 1-14 ISSN 0023-5954 R&D Projects: GA ČR GA102/02/0709 Institutional research plan: CEZ:AV0Z10750506 Keywords : polynomial matrix * second-order linear systems * LMI * pole placement * robust control Subject RIV: BC - Control Systems Theory Impact factor: 0.343, year: 2005

  8. Pole placement algorithm for control of civil structures subjected to earthquake excitation

    Directory of Open Access Journals (Sweden)

    Nikos Pnevmatikos

    2017-04-01

    Full Text Available In this paper the control algorithm for controlled civil structures subjected to earthquake excitation is thoroughly investigated. The objective of this work is the control of structures by means of the pole placement algorithm, in order to improve their response against earthquake actions. Successful application of the algorithm requires judicious placement of the closed-loop eigenvalues from the part of the designer. The pole placement algorithm was widely applied to control mechanical systems. In this paper, a modification in the mathematical background of the algorithm in order to be suitable for civil fixed structures is primarily presented. The proposed approach is demonstrated by numerical simulations for the control of both single and multi-degree of freedom systems subjected to seismic actions. Numerical results have shown that the control algorithm is efficient in reducing the response of building structures, with small amount of required control forces.

  9. Dominant pole placement with fractional order PID controllers: D-decomposition approach.

    Science.gov (United States)

    Mandić, Petar D; Šekara, Tomislav B; Lazarević, Mihailo P; Bošković, Marko

    2017-03-01

    Dominant pole placement is a useful technique designed to deal with the problem of controlling a high order or time-delay systems with low order controller such as the PID controller. This paper tries to solve this problem by using D-decomposition method. Straightforward analytic procedure makes this method extremely powerful and easy to apply. This technique is applicable to a wide range of transfer functions: with or without time-delay, rational and non-rational ones, and those describing distributed parameter systems. In order to control as many different processes as possible, a fractional order PID controller is introduced, as a generalization of classical PID controller. As a consequence, it provides additional parameters for better adjusting system performances. The design method presented in this paper tunes the parameters of PID and fractional PID controller in order to obtain good load disturbance response with a constraint on the maximum sensitivity and sensitivity to noise measurement. Good set point response is also one of the design goals of this technique. Numerous examples taken from the process industry are given, and D-decomposition approach is compared with other PID optimization methods to show its effectiveness. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Pole-placement Predictive Functional Control for under-damped systems with real numbers algebra.

    Science.gov (United States)

    Zabet, K; Rossiter, J A; Haber, R; Abdullah, M

    2017-11-01

    This paper presents the new algorithm of PP-PFC (Pole-placement Predictive Functional Control) for stable, linear under-damped higher-order processes. It is shown that while conventional PFC aims to get first-order exponential behavior, this is not always straightforward with significant under-damped modes and hence a pole-placement PFC algorithm is proposed which can be tuned more precisely to achieve the desired dynamics, but exploits complex number algebra and linear combinations in order to deliver guarantees of stability and performance. Nevertheless, practical implementation is easier by avoiding complex number algebra and hence a modified formulation of the PP-PFC algorithm is also presented which utilises just real numbers while retaining the key attributes of simple algebra, coding and tuning. The potential advantages are demonstrated with numerical examples and real-time control of a laboratory plant. Copyright © 2017 ISA. All rights reserved.

  11. Control of linear systems subject to time-domain constraints with polynomial pole placement and LMIs

    Czech Academy of Sciences Publication Activity Database

    Henrion, D.; Tarbouriech, S.; Kučera, Vladimír

    2005-01-01

    Roč. 50, č. 9 (2005), s. 1360-1364 ISSN 0018-9286 R&D Projects: GA MŠk 1M0567; GA ČR GA102/05/0011 Institutional research plan: CEZ:AV0Z10750506 Keywords : linear matrix inequality (LMI) * linear systems * pole placement * polynomials * time-domain constraints Subject RIV: BC - Control Systems Theory Impact factor: 2.159, year: 2005

  12. Artificial Intelligence based technique for BTS placement

    International Nuclear Information System (INIS)

    Alenoghena, C O; Emagbetere, J O; 1 Minna (Nigeria))" data-affiliation=" (Department of Telecommunications Engineering, Federal University of Techn.1 Minna (Nigeria))" >Aibinu, A M

    2013-01-01

    The increase of the base transceiver station (BTS) in most urban areas can be traced to the drive by network providers to meet demand for coverage and capacity. In traditional network planning, the final decision of BTS placement is taken by a team of radio planners, this decision is not fool proof against regulatory requirements. In this paper, an intelligent based algorithm for optimal BTS site placement has been proposed. The proposed technique takes into consideration neighbour and regulation considerations objectively while determining cell site. The application will lead to a quantitatively unbiased evaluated decision making process in BTS placement. An experimental data of a 2km by 3km territory was simulated for testing the new algorithm, results obtained show a 100% performance of the neighbour constrained algorithm in BTS placement optimization. Results on the application of GA with neighbourhood constraint indicate that the choices of location can be unbiased and optimization of facility placement for network design can be carried out

  13. A Direct Algorithm for Pole Placement by State-derivative Feedback for Single-input Linear Systems

    Directory of Open Access Journals (Sweden)

    Taha H. S. Abdelaziz

    2003-01-01

    Full Text Available This paper deals with the direct solution of the pole placement problem for single-input linear systems using state-derivative feedback. This pole placement problem is always solvable for any controllable systems if all eigenvalues of the original system are nonzero. Then any arbitrary closed-loop poles can be placed in order to achieve the desired system performance. The solving procedure results in a formula similar to the Ackermann formula. Its derivation is based on the transformation of a linear single-input system into Frobenius canonical form by a special coordinate transformation, then solving the pole placement problem by state derivative feedback. Finally the solution is extended also for single-input time-varying control systems. The simulation results are included to show the effectiveness of the proposed approach.

  14. Design, parametrization, and pole placement of stabilizing output feedback compensators via injective cogenerator quotient signal modules.

    Science.gov (United States)

    Blumthaler, Ingrid; Oberst, Ulrich

    2012-03-01

    Control design belongs to the most important and difficult tasks of control engineering and has therefore been treated by many prominent researchers and in many textbooks, the systems being generally described by their transfer matrices or by Rosenbrock equations and more recently also as behaviors. Our approach to controller design uses, in addition to the ideas of our predecessors on coprime factorizations of transfer matrices and on the parametrization of stabilizing compensators, a new mathematical technique which enables simpler design and also new theorems in spite of the many outstanding results of the literature: (1) We use an injective cogenerator signal module ℱ over the polynomial algebra [Formula: see text] (F an infinite field), a saturated multiplicatively closed set T of stable polynomials and its quotient ring [Formula: see text] of stable rational functions. This enables the simultaneous treatment of continuous and discrete systems and of all notions of stability, called T-stability. We investigate stabilizing control design by output feedback of input/output (IO) behaviors and study the full feedback IO behavior, especially its autonomous part and not only its transfer matrix. (2) The new technique is characterized by the permanent application of the injective cogenerator quotient signal module [Formula: see text] and of quotient behaviors [Formula: see text] of [Formula: see text]-behaviors B. (3) For the control tasks of tracking, disturbance rejection, model matching, and decoupling and not necessarily proper plants we derive necessary and sufficient conditions for the existence of proper stabilizing compensators with proper and stable closed loop behaviors, parametrize all such compensators as IO behaviors and not only their transfer matrices and give new algorithms for their construction. Moreover we solve the problem of pole placement or spectral assignability for the complete feedback behavior. The properness of the full feedback behavior

  15. DECOUPLING CONTROL OF TITO SYSTEM SUPPORTED BY DOMINANT POLE PLACEMENT METHOD

    Directory of Open Access Journals (Sweden)

    Novak N. Nedić

    2017-08-01

    Full Text Available Appropriate approach to the nature of systems is a significant precondition for its successful control. An always actual issue of its mutual coupling is considered in this paper. A multivariable system with two-inputs and two-outputs (TITO is in the focus here. The dominant pole placement method is used in trying to tune the PID controllers that should support the decoupling control. The aim is to determine parameters of the PID controllers which, in combination with decoupler, can obtain a good dynamical behavior of the system. Therefore, this kind of the centralized analytically obtained controller is used for object control. Another goal is to simplify the tuning procedure of PID controllers and enlarge the possibility for introducing the given approach into practice. But the research results indicate that the proposed procedure leads to the usage of P controllers because they enable the best performances for the considered object. Also, it is noticed that some differences from the usual rules in selection of the dominant poles gives better results. The research is supported by simulations and, therefore, the proposed method effectiveness, regarding the system behavior quality, is presented on several examples.

  16. The design of multi-lead-compensators for stabilization and pole placement in double-integrator networks under saturation

    NARCIS (Netherlands)

    Wan, Yan; Roy, Sandip; Saberi, Ali; Stoorvogel, Antonie Arij

    2009-01-01

    We study decentralized controller design for stabilization and pole-placement, in a network of autonomous agents with double-integrator internal dynamics and arbitrary observation topology. We show that a simple multi-lead-compensator architecture, in particular one in which each agent uses a

  17. The design of multi-lead-compensators for stabilization and pole placement in double-integrator networks

    NARCIS (Netherlands)

    Wan, Yan; Roy, Sandip; Saberi, Ali; Stoorvogel, Antonie Arij

    2010-01-01

    We study decentralized controller design for stabilization and pole-placement, in a network of autonomous agents with double-integrator internal dynamics and arbitrary observation topology. We show that a simple multi-lead-compensator architecture, in particular one in which each agent uses a

  18. Post-placement temperature reduction techniques

    DEFF Research Database (Denmark)

    Liu, Wei; Nannarelli, Alberto

    2010-01-01

    With technology scaled to deep submicron era, temperature and temperature gradient have emerged as important design criteria. We propose two post-placement techniques to reduce peak temperature by intelligently allocating whitespace in the hotspots. Both methods are fully compliant with commercial...... technologies, and can be easily integrated with state-of-the-art thermal-aware design flow. Experiments in a set of tests on circuits implemented in STM 65nm technologies show that our methods achieve better peak temperature reduction than directly increasing circuit's area....

  19. Adaptive robust pole-placement control of 4-leg voltage-source inverters for standalone photovoltaic systems: Considering digital delays

    International Nuclear Information System (INIS)

    Nasiri, Reza; Radan, Ahmad

    2011-01-01

    Three leg inverters for photovoltaic systems have a lot of disadvantages, especially when the load is unbalanced. These disadvantages are for example, small utilization of the DC link voltage, the dependency of the modulation factor of the load current and the superposition of a DC component with the output AC voltage. A solution for these problems is the 4-leg inverter. Most papers dealing with 4-leg inverters ignore the effect of digital delays in control loop and suggest classic controllers, such as PI controller. However, the transient performance of the system does not become adjustable by applying classic control techniques. Additionally, adaptive control techniques have not yet been discussed for 4-leg inverters. This paper proposes the pole-placement control strategy via state feedback with integral state, which is a modern control technique, to control the system. Consequently, resulted system becomes highly robust. In addition, it suggests a Self-Tuner Regulator to guarantee the adaptive performance of the final system. Moreover, it proposes a novel model, considering digital delays, for 4-leg inverters. Simulation results show that transient performance of the system becomes accurately adjustable and the 4-leg inverter generates balanced voltage, with sinusoidal waveform, in spite of the presence of RL time variant loads.

  20. A Multi-Modal Control Using a Hybrid Pole-Placement-Integral Resonant Controller (PPIR) with Experimental Investigations

    DEFF Research Database (Denmark)

    Nielsen, Søren R.K.; Basu, Biswajit

    2011-01-01

    vibrations e.g. caused by broad-band turbulent wind excitations. Hence, the proposed hybrid controller can effectively suppress complex multi-modal vibrations in flexible systems. Both numerical and experimental studies have been carried out to demonstrate the effectiveness of the proposed algorithm using......Control of multi-modal structural vibrations has been an important and challenging problem in flexible structural systems. This paper proposes a new vibration control algorithm for multi-modal structural control. The proposed algorithm combines a pole-placement controller with an integral resonant...... controller. The pole-placement controller is used to achieve a target equivalent modal viscous damping in the system and helps in the suppression of higher modes, which contribute to the vibration response of flexible structures. The integral resonant controller successfully reduces the low frequency...

  1. PI controller design of a wind turbine: evaluation of the pole-placement method and tuning using constrained optimization

    DEFF Research Database (Denmark)

    Mirzaei, Mahmood; Tibaldi, Carlo; Hansen, Morten Hartvig

    2016-01-01

    PI/PID controllers are the most common wind turbine controllers. Normally a first tuning is obtained using methods such as pole-placement or Ziegler-Nichols and then extensive aeroelastic simulations are used to obtain the best tuning in terms of regulation of the outputs and reduction of the loads...... to automatically tune the wind turbine controller subject to robustness constraints. The properties of the system such as the maximum sensitivity and complementary sensitivity functions (Ms and Mt), along with some of the responses of the system, are used to investigate the controller performance and formulate...

  2. Detection of Cavities Using Pole-Dipole Resistivity Technique

    OpenAIRE

    Elawadi, Eslam; El-Qady, Gad; Salem, Ahmed; Ushijima, Keisuke

    2001-01-01

    Using pole-dipole array, electrical resistivity survey was conducted to investigate the subsurface under a subsiding building located in Kita Kyushu area, Japan. The resistivity measurements were acquired along two traverse lines and interpreted using a g

  3. Ridge Splitting Technique for Horizontal Augmentation and Immediate Implant Placement

    Directory of Open Access Journals (Sweden)

    Papathanasiou Ioannis

    2014-03-01

    Full Text Available Insufficient width of the alveolar ridge often prevents ideal implant placement. Guided bone regeneration, bone grafting, alveolar ridge splitting and combinations of these techniques are used for the lateral augmentation of the alveolar ridge. Ridge splitting is a minimally invasive technique indicated for alveolar ridges with adequate height, which enables immediate implant placement and eliminates morbidity and overall treatment time. The classical approach of the technique involves splitting the alveolar ridge into 2 parts with use of ostetomes and chisels. Modifications of this technique include the use of rotating instrument, screw spreaders, horizontal spreaders and ultrasonic device.

  4. Soft-Tissue Grafting Techniques Associated With Immediate Implant Placement.

    Science.gov (United States)

    Bishara, Mark; Kurtzman, Gregori M; Khan, Waji; Choukroun, Joseph; Miron, Richard J

    2018-02-01

    Immediate implant placement often presents challenges in terms of predictably obtaining soft-tissue coverage over the implant site. While delayed implant placement offers the ability for soft tissues to grow and invade the extraction socket making their attachment around implants more predictable, immediate implant placement poses a significant risk of bacterial invasion towards the implant surface as a result of insignificant soft-tissue volume. Soft-tissue grafting techniques have often been proposed for use during immediate implant placement to augment soft-tissue deficiencies, including the use of either palatal connective tissue grafts (CTGs) or collagen-derived scaffolds. However, both of these approaches have significant drawbacks in that CTGs are harvested with high patient morbidity and collagen scaffolds remain avascular and acelluar posing a risk of infection/implant contamination. More recently, platelet-rich fibrin (PRF) has been proposed as an economical and biological means to speed soft-tissue wound healing. In combination with immediate implant placement, PRF offers an easily procurable low-cost regenerative modality that offers an efficient way to improve soft-tissue attachment around implants. Furthermore, the supra-physiological concentration of defense-fighting leukocytes in PRF, combined with a dense fibrin meshwork, is known to prevent early bacterial contamination of implant surfaces, and the biological concentrations of autologous growth factors in PRF is known to increase tissue regeneration. This article discusses soft-tissue grafting techniques associated with immediate implant placement, presents several cases demonstrating the use of PRF in routine immediate implant placement, and further discusses the biological and economic advantages of PRF for the management of soft-tissue grafting during immediate implant placement.

  5. Stabilization Using a Discrete Fuzzy PDC Control with PID Controllers and Pole Placement: Application to an Experimental Greenhouse

    Directory of Open Access Journals (Sweden)

    Amine Chouchaine

    2011-01-01

    Full Text Available This paper proposes a control strategy for complex and nonlinear systems, based on a parallel distributed compensation (PDC controller. A solution is presented to solve a stability problem that arises when dealing with a Takagi-Sugeno discrete system with great numbers of rules. The PDC controller will use a classical controller like a PI, PID, or RST in each rule with a pole placement strategy to avoid causing instability. The fuzzy controller presented combines the multicontrol approach and the performance of the classical controllers to obtain a robust nonlinear control action that can also deal with time-variant systems. The presented method was applied to a small greenhouse to control its inside temperature by variation in ventilation rate inside the process. The results obtained will show the efficiency of the adopted method to control the nonlinear and complex systems.

  6. Cervical Pedicle Screw Placement Using Medial Funnel Technique.

    Science.gov (United States)

    Lee, Jung Hwan; Choi, Byung Kwan; Han, In Ho; Choi, Won Gyu; Nam, Kyoung Hyup; Kim, Hwan Soo

    2017-09-01

    Cervical pedicle screw (CPS) placement is very challenging due to high risk of neurovascular complications. We devised a new technique (medial funnel technique) to improve the accuracy and feasibility of CPS placement. We reviewed 28 consecutive patients undergoing CPS instrumentation using the medial funnel technique. Their mean age was 51.4 years (range, 30-81 years). Preoperative diagnosis included degenerative disease (n=5), trauma (n=22), and infection (n=1). Screw perforations were graded with the following criteria: grade 0 having no perforation, grade 1 having 50% of screw diameter. Grades 0 and 1 were considered as correct position. The degree of perforation was determined by 2 junior neurosurgeons and 1 senior neurosurgeon. A total of 88 CPSs were inserted. The rate of correct placement was 94.3%; grade 0, 54 screws; grade 1, 29 screws; grade 2, 4 screws; and grade 3, 1 screw. No neurovascular complications or failure of instrumentation occurred. In perforated screws (34 screws), lateral perforations were 4 and medial perforations were 30. We performed CPS insertion using medial funnel technique and achieved 94.3% (83 of 88) of correct placement. And it can decrease lateral perforation.

  7. Comparison of different techniques of laryngeal mask placement in children.

    Science.gov (United States)

    Ghai, Babita; Wig, Jyotsna

    2009-06-01

    The insertion of laryngeal mask airway is not always easy in children, and many techniques are described to improve success rate of placement. It is very important to determine the optimal insertion technique as unsuccessful prolonged insertion and multiple attempts are associated with adverse respiratory events and trauma in children. This article will review different techniques studied recently for the placement of classical laryngeal mask airway in children as well as recent findings of cuff pressure and depth of anesthesia for laryngeal mask airway placement. Laryngeal mask airway in children has undergone many modifications such as ProSeal laryngeal mask airway to improve its functioning. This article will also review different insertion techniques for ProSeal laryngeal mask airway. Rotational technique with partially inflated cuff is reported to have the highest success rate of insertion and lowest incidence of complications for classical laryngeal mask airway in children. Clinical endpoints for cuff inflation are associated with significant hyperinflation and increased leakage around the laryngeal mask airway cuff. The inferences regarding the dosage of intravenous anesthetic agents and end-tidal concentration of volatile anesthetics in children to achieve adequate depth for laryngeal mask airway placement are very difficult to draw. ProSeal laryngeal mask airway is associated with a very high first attempt success and overall success of insertion in children. Rotational technique may be considered as the first technique of choice for classical laryngeal mask airway insertion in children. The routine use of cuff pressure monitoring is mandatory during the use of laryngeal mask airway in children. Modification of laryngeal mask airway in children, that is ProSeal laryngeal mask airway, is promising and improves the success rate of insertion.

  8. A novel placement technique for nasogastric and nasoesophageal tubes.

    Science.gov (United States)

    Herring, Jennifer M

    2016-07-01

    Early enteral nutrition in dogs and cats can have significant benefit in the therapeutic management of critical illness. Blind placement of nasogastric or nasoesophageal feeding tubes to accomplish this goal has become standard practice. However, complications from tube misdirection into the tracheobronchial tree can lead to significant patient morbidity and mortality. Safe and consistent alternatives are desirable to minimize these risks. A modified method for placement of nasoenteric tubes is described. The main variation from standard procedure involves a second tube measurement, with the distal tip of the tube positioned at the thoracic inlet and measured to the nostril. The tube is advanced to this level and tested for negative pressure using a 12 mL syringe attached to the end of the feeding tube. This improves confidence in esophageal positioning before complete advancement of the tube to its distal endpoint. This procedural adaptation to feeding tube placement has the potential to reduce bronchopulmonary trauma from intratracheal misdirection by providing an early safety check to identify malpositioning. Prospective validation studies are needed to support its advantages over standard tube placement techniques. © Veterinary Emergency and Critical Care Society 2016.

  9. A Novel Endoscopic Technique for Failed Nasogastric Tube Placement.

    Science.gov (United States)

    Boston, Andrew G

    2015-10-01

    Direct visualization of the nasopharynx gives the otolaryngologist a unique advantage for addressing difficult nasopharyngeal anatomy. One common situation is being consulted to assist when the blind placement of a nasogastric tube has failed. A novel technique for managing a patient with a nasogastric tube embedded in the adenoid remnant is described with illustrations. The atraumatic method is easily employed by a resident armed with a portable nasolaryngoscope and plain suture. By using a repeated pull-through technique, the nasogastric tube can be guided past difficult nasopharyngeal anatomy and into a position from where it can be advanced into the patient's esophagus. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.

  10. Fully customized placement of orthodontic miniplates: a novel clinical technique

    Science.gov (United States)

    2014-01-01

    Introduction The initial stability and survival rate of orthodontic mini-implants are highly dependent on the amount of cortical bone at their insertion site. In areas with limited bone availability, mini-plates are preferred to provide effective skeletal anchorage. The purpose of this paper was to present a new clinical technique for the insertion of mini-plates. Methods In order to apply this new technique, a cone-beam image of the insertion area is required. A software (Galaxy Sirona, Bensheim, Germany) is used to construct a three-dimensional image of the scanned area and to virtually determine the exact location of the mini-plate as well as the position of the fixation screws. A stereolithographic model (STL) is then created by means of a three-dimensional scanner. Prior to its surgical insertion, the bone plate is adapted to the stereo-lithographic model. Finally, a custom transfer jig is fabricated in order to assist with accurate placement of the mini-plate intra-operatively. Results The presented technique minimizes intra-operative decision making, because the final position of the bone plate is determined pre-surgically. This significantly reduces the duration of the surgical procedure and improves its outcome. Conclusions A novel method for surgical placement of orthodontic mini-plates is presented. The technique facilitates accurate adaptation of mini-plates and insertion of retaining surgical screws; thereby enabling clinicians to more confidently increase the use of bone plates, especially in anatomical areas where the success of non-osseointegrated mini-screws is less favorable. PMID:24886597

  11. Self-tuning pressure-feedback control by pole placement for vibration reduction of excavator with independent metering fluid power system

    Science.gov (United States)

    Ding, Ruqi; Xu, Bing; Zhang, Junhui; Cheng, Min

    2017-08-01

    Independent metering control systems are promising fluid power technologies compared with traditional valve controlled systems. By breaking the mechanical coupling between the inlet and outlet, the meter-out valve can open as large as possible to reduce energy consumptions. However, the lack of damping in outlet causes stronger vibrations. To address the problem, the paper designs a hybrid control method combining dynamic pressure-feedback and active damping control. The innovation resides in the optimization of damping by introducing pressure feedback to make trade-offs between high stability and fast response. To achieve this goal, the dynamic response pertaining to the control parameters consisting of feedback gain and cut-off frequency, are analyzed via pole-zero locations. Accordingly, these parameters are tuned online in terms of guaranteed dominant pole placement such that the optimal damping can be accurately captured under a considerable variation of operating conditions. The experiment is deployed in a mini-excavator. The results pertaining to different control parameters confirm the theoretical expectations via pole-zero locations. By using proposed self-tuning controller, the vibrations are almost eliminated after only one overshoot for different operation conditions. The overshoots are also reduced with less decrease of the response time. In addition, the energy-saving capability of independent metering system is still not affected by the improvement of controllability.

  12. Immediate implant placement: surgical techniques for prevention and management of complications.

    Science.gov (United States)

    Al-Sabbagh, Mohanad; Kutkut, Ahmad

    2015-01-01

    Loss of soft and hard tissue is common after tooth extraction. Substantial resorption of alveolar bone compromises esthetics and may result in prosthetic and surgical limitations. Immediate implant placement at the time of tooth extraction is used to maintain alveolar ridge dimensions. Clinical studies support the successful outcome of immediate placement of dental implants in fresh extraction sockets; comparative clinical studies have found that implant survival rates after immediate placement are similar to those after delayed placement. This article addresses surgical techniques for immediate implant placement and the prevention and the management of complications associated with this procedure. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    International Nuclear Information System (INIS)

    Dasgupta, Niloy; Lungren, Matthew P.; Patel, Manish N.; Racadio, John M.; Johnson, Neil D.

    2016-01-01

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  14. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, Niloy; Lungren, Matthew P. [Lucile Packard Children' s Hospital Stanford, Department of Radiology, Palo Alto, CA (United States); Patel, Manish N.; Racadio, John M.; Johnson, Neil D. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-09-15

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  15. Proximal marginal overhang of composite restorations in relation to placement technique of separation rings.

    NARCIS (Netherlands)

    Loomans, B.A.C.; Opdam, N.J.M.; Roeters, F.J.M.; Huysmans, M.C.D.N.J.M.

    2012-01-01

    The aim was to investigate in vitro the marginal overhang in Class II composite restorations placed with various separation rings and placement techniques. A total of 180 Mesial-Occlusal [MO] preparations in artificial molar teeth were divided into nine groups (n=20). After placement of the

  16. Pole Shape Optimization of Permanent Magnet Synchronous Motors Using the Reduced Basis Technique

    Directory of Open Access Journals (Sweden)

    A. Jabbari

    2010-03-01

    Full Text Available In the present work, an integrated method of pole shape design optimization for reduction of torque pulsation components in permanent magnet synchronous motors is developed. A progressive design process is presented to find feasible optimal shapes. This method is applied on the pole shape optimization of two prototype permanent magnet synchronous motors, i.e., 4-poles/6-slots and 4-poles-12slots.

  17. Poling of Planar Silica Waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Kristensen, Martin; Jensen, Jesper Bo

    1999-01-01

    UV-written planar silica waveguides are poled using two different poling techniques, thermal poling and UV-poling. Thermal poling induces an electro-optic coefficient of 0.067 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. The induced electro-optic effect shows a linear dependence...

  18. An in vitro evaluation of microleakage associated with three different compomer placement techniques in primary molars

    Directory of Open Access Journals (Sweden)

    Mohita Gupta

    2017-01-01

    Full Text Available Background: Microleakage is one of the most frequently encountered problems in posterior tooth-colored restorations. Efforts to decrease this problem with resin restorations include techniques for reducing the ratio of bonded to unbonded restoration surfaces and following strategic incremental placement techniques to reduce residual stress at tooth-restoration interface which reduces the C-factor, hence microleakage. Aim: The present study aimed to evaluate microleakage associated with three placement techniques for compomer restorations in primary molars. Design and Methodology: This in vitro experimental study assessed the microleakage associated with bulk-fill, horizontal-incremental, and oblique-incremental compomer placement techniques in primary molars. Ninety specimens were divided into three groups of thirty for each of the placement techniques. Results: Nearly 86.6% of the specimens presented with microleakage involving the entire axial wall and pulpal floor in the bulk-fill group, whereas 56.6% and 46.6% of the specimens in the horizontal-incremental and oblique-incremental groups showed microleakage up to two-third and one-third of the axial walls, respectively. A significant difference in scores was observed between groups (P < 0.001. Conclusion: Microleakage was observed with all the three techniques but was comparatively lower with the incremental placement techniques. The oblique-incremental technique offered the least microleakage.

  19. [Comparison of accuracy of pedicle screw placement in the thoracic spine using funnel technique and free hand technique].

    Science.gov (United States)

    Wang, Tao; Tang, Cheng-xuan; Yang, Guo-jing; Yu, Bin-feng; Zhang, Li-cheng

    2009-08-01

    To study the accuracy the pedicle screw placement in the thoracic spine using funnel technique and free hand technique. Eight cadavers including 5 males and 3 females were analysed. The age ranged from 57 to 82 years (mean 68 years). Cadawers were randomly assigned to one of two instrumentation groups. In four cadavers, "funnel technique" was used for screw placement. In the remaining four cadavers,free hand technique then was used. Success of pedicle screw placement was judged by CT scan. The rate of success of two ways was compared using statistic analysis. Ninety-six screws were inserted by "funnel technique" and free hand technique respectively, 84 of "funnel technique" were successful, and 73 of free hand technique were successful. Significant differences were found between two ways (P funnel technique" on 2 screws and free hand technique on 9 screws. There were significant differences in rates of chanciness tresis (P Funnel technique is simple, safe and cost-effective alternative to any other thchnique for pedicle screw placement in thoracic spine,funnel technique is able to reduce the chance of critical injury of nerve root and dura.

  20. Flapless versus open flap techniques of implant placement: A 15-month follow-up study

    Directory of Open Access Journals (Sweden)

    Bhavita Wadhwa

    2015-01-01

    Conclusions: Both techniques showed a reduction in CBH with time but the flapless technique showed a lesser reduction. Therefore, the flapless technique can be considered as a better treatment approach for placement of implants, especially where adequate width and height of available bone are present.

  1. Rotor Pole Shape Optimization of Permanent Magnet Brushless DC Motors Using the Reduced Basis Technique

    Directory of Open Access Journals (Sweden)

    GHOLAMIAN, A. S.

    2009-06-01

    Full Text Available In this paper, a magnet shape optimization method for reduction of cogging torque and torque ripple in Permanent Magnet (PM brushless DC motors is presented by using the reduced basis technique coupled by finite element and design of experiments methods. The primary objective of the method is to reduce the enormous number of design variables required to define the magnet shape. The reduced basis technique is a weighted combination of several basis shapes. The aim of the method is to find the best combination using the weights for each shape as the design variables. A multi-level design process is developed to find suitable basis shapes or trial shapes at each level that can be used in the reduced basis technique. Each level is treated as a separated optimization problem until the required objective is achieved. The experimental design of Taguchi method is used to build the approximation model and to perform optimization. This method is demonstrated on the magnet shape optimization of a 6-poles/18-slots PM BLDC motor.

  2. Parallel insertion endoscopic technique for precise catheter placement in cystic craniopharyngiomas.

    Science.gov (United States)

    Mori, Ryosuke; Joki, Tatsuhiro; Nonaka, Yuichiro; Ikeuchi, Satoshi; Abe, Toshiaki

    2014-11-01

    Total removal of craniopharyngioma is the most acceptable therapeutic modality; however, there are cases in which radical excision is not possible. To reduce the cystic component volume, an Ommaya reservoir catheter can be placed endoscopically. However, there are certain complications and risks with this type of maneuver, such as misplacement of the catheter, which may result in leakage of cyst contents or installed fluids such as bleomycin. Thus, accurate placement of intracystic catheter is extremely important. The authors placed Ommaya reservoir catheters running over the outer surface of a transparent endoscopic sheath in three cases. This neuroendoscopic procedure permits easier manipulation of the catheter and precise placement of the catheter tip. This technique was useful for placement of Ommaya reservoir catheters. This new technique of catheter placement with neuroendoscopy is more accurate, safer, and less invasive. Georg Thieme Verlag KG Stuttgart · New York.

  3. A moving pole-placement compensation design method to increase the bandwidth of RC-damper-based dual “Buck-Boost” AC/DC converter

    DEFF Research Database (Denmark)

    Wu, Weimin; Qin, Weibo; Wang, Houqin

    2017-01-01

    the “Buck” mode, the control-to-grid current transfer function of this dual “Buck-Boost” AC/DC converter has a movable zero, which is related to the input power and the output DC voltage. When the input power increases, the movable zero will slide to the lower frequency range. And then, the gain between...... the cut-off frequency point and the resonant frequency of LCL filter will swell up, resulting in reduced amplitude margin and suppressed bandwidth of system. Based on the theoretical analysis, a new dynamic pole placement compensation control design method is proposed for this dual AC/DC converter......Recently, an LCL-filter-based dual “Buck-Boost” AC/DC converter for DC Nano-grid with three terminal outputs was proposed. Since it is a high order filter based single-phase converter, a RC damper is adopted to keep the system stable. This converter has two work modes: “Boost” and “Buck”. During...

  4. Mapping the temporal pole with a specialized electrode array: technique and preliminary results

    International Nuclear Information System (INIS)

    Abel, Taylor J; Rhone, Ariane E; Nourski, Kirill V; Oya, Hiroyuki; Kawasaki, Hiroto; Howard, Matthew A III; Granner, Mark A; Tranel, Daniel T; Griffiths, Timothy D

    2014-01-01

    Temporopolar cortex plays a crucial role in the pathogenesis of temporal lobe epilepsy and subserves important cognitive functions. Because of its shape and position in the middle cranial fossa, complete electrode coverage of the temporal pole (TP) is difficult to achieve using existing devices. We designed a novel TP electrode array that conforms to the surface of temporopolar cortex and achieves dense electrode coverage of this important brain region. A multi-pronged electrode array was designed that can be placed over the surface of the TP using a straightforward insertion technique. Twelve patients with medically intractable epilepsy were implanted with the TP electrode array for purposes of seizure localization. Select patients underwent cognitive mapping by electrocorticographic (ECoG) recording from the TP during a naming task. Use of the array resulted in excellent TP electrode coverage in all patients. High quality ECoG data were consistently obtained for purposes of delineating seizure activity and functional mapping. During a naming task, significant increases in ECoG power were observed within localized subregions of the TP. One patient developed a transient neurological deficit thought to be related to the mass effect of multiple intracranial recording arrays, including the TP array. This deficit resolved following removal of all electrodes. The TP electrode array overcomes limitations of existing devices and enables clinicians and researchers to obtain optimal multi-site recordings from this important brain region. (paper)

  5. Stainless Steel Crown Placement Utilizing the Hall Technique

    Science.gov (United States)

    2017-03-23

    Technique presented at/published to HINMAN Dental Society, 33 Lenox Pointe NE, Atlanta, GA, 23-25 March 2017 in accordance with MDWI 41-108, has...been approved and assigned local file #17124. 2. Pertinent biographic information (name of author(s), title, etc.) has been entered into our computer ...member, we can forward your request for funds to the designated Wing POC at the Chief Scientist’ s Office, Ms. Al ice Houy, office phone: 210-292-8029

  6. Ultrasound-guided or landmark techniques for central venous catheter placement in critically ill children.

    Science.gov (United States)

    Oulego-Erroz, Ignacio; González-Cortes, Rafael; García-Soler, Patricia; Balaguer-Gargallo, Mónica; Frías-Pérez, Manuel; Mayordomo-Colunga, Juan; Llorente-de-la-Fuente, Ana; Santos-Herraiz, Paula; Menéndez-Suso, Juan José; Sánchez-Porras, María; Palanca-Arias, Daniel; Clavero-Rubio, Carmen; Holanda-Peña, Mª Soledad; Renter-Valdovinos, Luis; Fernández-De-Miguel, Sira; Rodríguez-Núñez, Antonio

    2018-01-01

    To assess whether ultrasound guidance improves central venous catheter placement outcomes compared to the landmark technique in critically ill children. A prospective multicentre observational study was carried out in 26 paediatric intensive care units over 6 months. Children 0-18 years old who received a temporary central venous catheter, inserted using either ultrasound or landmark techniques, were eligible. The primary outcome was the first-attempt success rate. Secondary outcomes included overall placement success, number of puncture attempts, number of procedures requiring multiple punctures (> 3 punctures), number of procedures requiring punctures at more than one vein site and immediate mechanical complications. To account for potential confounding factors, we used propensity scores. Our primary analysis was based on 1:1 propensity score matching. The association between cannulation technique and outcomes in the matched cohort was estimated using generalized estimating equations and mixed-effects models to account for patient-level and hospital-level confounders. Five hundred central venous catheter-placement procedures involving 354 patients were included. Ultrasound was used for 323 procedures, and the landmark technique was used for 177. Two hundred and sixty-six procedures were matched (133 in the ultrasound group and 133 in the landmark group). Ultrasound was associated with an increase in the first-attempt success rate [46.6 vs. 30%, odds ratio 2.09 (1.26-3.46); p central venous catheter placement in critically ill children.

  7. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique.

    Science.gov (United States)

    Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.

  8. Development and characterization of a technique for percutaneous radiologic gastrojejunostomy tube placement in the dog.

    Science.gov (United States)

    Mack, Rebekah M; Staiger, Benjamin; Langlois, Daniel K; Mehler, Stephen J; Lam, Nathaniel; Moore, Trevor; Brown, Andrew; Beal, Matthew W

    2016-09-01

    To develop and describe a technique for percutaneous radiologic gastrojejunostomy tube placement in the dog. Prospective technique development study. University teaching hospital. Six healthy adult male Beagles. Following anesthetic induction, fluoroscopic and ultrasound guidance were used to identify an appropriate gastropexy site on the left lateral abdomen. Gastropexy was performed using gastrointestinal suture anchors. An over-the-wire catheter technique using fluoroscopic guidance was used to achieve jejunal access. An 18F/8F, 58 cm, dual-lumen gastrojejunal feeding tube was placed via serial over-the-wire dilation of the body wall using an 18F peel-away introducer kit. Tube location was determined radiographically immediately following placement and on days 2, 4, after emesis on day 4, and at time of gastrojejunal feeding tube removal (day 16-18). Percutaneous radiologic gastrojejunostomy (PRGJ) tube placement was successful in all dogs. Median time to pyloric passage with the guide wire was 23.5 minutes (range, 9-93 minutes). Median total procedure time was 53 minutes (range, 49-113 minutes). Significant tube migration was not observed at any point during the study. One dog developed linear foreign body obstruction secondary to the tube on day 5 that was relieved by release of the jejunal component. Other complications were minor and included mild-to-moderate peristomal inflammation in all dogs and removal of the feeding tube on day 3 by 1 dog. Feedings were well tolerated in all dogs. PRGJ tube placement in the dog is a safe and minimally invasive technique that allows for jejunal feeding without surgery or endoscopy. The high success rates, acceptable procedural times, and minimal complications are appealing for use in critically ill patients. Although additional evaluations are needed, PRGJ tube placement may be considered for dogs that require postpyloric feeding with or without gastric decompression. © Veterinary Emergency and Critical Care Society

  9. Viewers and brand placement in movies: new insights about viewers contribute to better understand the effectiveness of the technique

    OpenAIRE

    Jean-Marc Lehu; Etienne Bressoud

    2007-01-01

    Several studies have shown the potential of product placement use. Since traditional media have become saturated, this communication technique benefits from growing interest. Consequently, product and/or brand placements have mushroomed, especially in Hollywood movies, but not always with the same effectiveness. Rather than focusing on the placement itself, this research proposes to explore new insights concerning viewers' reaction during the second step exposure. A sample of 3,532 DVD French...

  10. Ball tip technique for thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis.

    Science.gov (United States)

    Watanabe, Kota; Matsumoto, Morio; Tsuji, Takashi; Ishii, Ken; Takaishi, Hironari; Nakamura, Masaya; Toyama, Yoshiaki; Chiba, Kazuhiro

    2010-08-01

    The aim in this study was to evaluate the efficacy of the ball tip technique in placing thoracic pedicle screws (TPSs), as compared with the conventional freehand technique, in both a cadaveric study and a clinical study of patients with adolescent idiopathic scoliosis. Although posterior spinal surgery using TPSs has been widely applied, these screws are associated with the potential risk of vascular, pulmonary, or neurological complications. To further enhance the accuracy and safety of TPS placement, the authors developed the ball tip technique. After creating an appropriate starting point for probe insertion, a specially designed ball tip probe consisting of a ball-shaped tip with a flexible metal shaft is used to make a guide hole into the pedicle. Holding the probe with the fingertips while using an appropriate amount of pressure or by tapping it gently and continuously with a hammer, one can safely insert the ball tip probe into the cancellous channel in the pedicle. In a cadaveric study, 5 spine fellows with similar levels of experience in placing TPSs applied the ball tip or the conventional technique to place screws in 5 cadavers with no spinal deformities. The incidence of misplaced screws was evaluated by dissecting the spines. In a clinical study, 40 patients with adolescent idiopathic scoliosis underwent posterior surgery with TPS placement via the ball tip or conventional technique (20 patients in each treatment group). The accuracy of the TPS placements was evaluated on postoperative axial CT scanning. In the cadaveric study, 100 TPSs were evaluated, and the incidence of misplaced screws was 14% in the ball tip group and 34% in the conventional group (p = 0.0192). In the clinical study, 574 TPSs were evaluated. One hundred seventy-one intrapedicular screws (67%) were recognized in the conventional group and 288 (90%) in the ball tip group (p ball tip groups, the respective numbers of TPSs with a pedicle breach of 2 mm were 32 (13%) and 9 (3%; p ball

  11. Ultrasound-guided epidural catheter placement with a new technique: preliminary cadaveric study.

    Directory of Open Access Journals (Sweden)

    Elisa Silvia D'Urso

    2017-05-01

    Full Text Available Several methods are described in veterinary medicine to perform and assess correct epidural needle placement to provide effective epidural analgesia (Adami et al 2017. The aim of this study is to evaluate the feasibility of an ultrasound longitudinal sagittal approach to epidural catheter placement using a biopsy needle guide. Seven dog cadavers were used in the study. With the cadaver in sternal recumbence, a 5-8 MHz microconvex transducer provided with a 16-gauge biopsy guide was positioned to obtain a longitudinal sagittal scan of the spinal process of L7 and the sacral crest; the epidural space was identified between two parallel hyperechoic lines and, as the trajectory of the biopsy guide crossed them, a 17G Tuohy needle was used to insert a 19G epidural catheter. Correct catheter placement was visualised through a resection of the column between L2 and L3. Firstly, an expert echographist (operator C1 visualised the ultrasonographic landmarks, while catheter placement was performed by an expert anaesthetist (operator A, a student (operator B and another expert echographist (operator C2 (double-operator technique; secondly, operator A and C2 performed alone the whole procedure (single-operator technique; lastly all operators performed a blind procedure (Jones 2001. Operator A failed 2/7 single-operator procedures; time to perform the blind technique was statistically lower than the double-operator technique (75 ± 132.4 vs 91.6 ± 79.3 seconds. Operator C2 failed 3/7 blind procedures, scoring the higher total time of performance (329.3 ± 271.2 seconds, but was able to perform both the double- and single-operator technique without significant difference with operator A, despite a faster time in positioning the probe. Operator B showed a higher repositioning attempts of the needle with the double-operator procedure compared to the blind one. Ultrasound guidance appears to be a promising technique to ease catheter placement also by operators

  12. Virtual planning of dental implant placement using CT double scan-technique - own experience

    International Nuclear Information System (INIS)

    Wojciechowski, W.; Urbanik, A.; Kownacki, P.; Kownacki, S.

    2007-01-01

    The correctness of CT performed with the use of a double-scan technique is the basis for achieving proper quality of 3D reconstructions of the maxilla or mandible and subsequent virtual planning of dental implant placement. The aim of this study was the presentation of the methodology of computed tomography scanning and own experience with the use of the double-scan technique. The study group included 26 individuals who underwent MDCT with a double-scan technique using a MDCT scanner SOMATOM Sensation (Siemens, Germany). The parameters of the examination: slice-collimation 10 x 0.75 mm, slice-thickness 0.75 mm. The first CT scan in the procedure was the scan of the patient wearing a radiological prosthesis and occlusal index, which was followed by a separate scan of the radiological prosthesis. These two CT scans were copied and transferred to PC with Procera Software program (Nobel Biocare, Sweden) where dental implant placement was virtually planned. In all 26 patients, precise three-dimensional reconstructions of the anatomical structure were obtained. In 11 patients, on the basis of the virtual planning, the implant placement was performed, 5 patients were referred to preparatory procedures, that is, restoration of the alveolar process, otolaryngological treatment of the maxillary sinuses. The remaining 10 patients did not qualify to the procedure because of unfavorable anatomical ideation's. Correct computed tomography with double-scan technique enables virtual planning of dental implant placement, on the basis of which the real procedure of implantation can be performed. (author)

  13. Wound complications after chemo-port placement in children: Does closure technique matter?

    Science.gov (United States)

    Muncie, Colin; Herman, Richard; Collier, Anderson; Berch, Barry; Blewett, Christopher; Sawaya, David

    2018-03-01

    Wound dehiscence after chemo-port placement is a rare but potentially significant complication. We hypothesize that by using a simple running skin closure technique during chemo-port placement the rate of wound dehiscence and overall wound complications can be significantly decreased. IRB approval was obtained and patients port from June 2012 to April 2016 were analyzed. Data collected on patients included patient demographics, skin closure type, and wound complications within 30days. Chi-square was performed to examine the univariate association with skin closure technique and wound dehiscence. Logistic regression was performed to examine the multivariable association between skin closure type and wound dehiscence and to compute odds ratios. There were 259 ports placed in this cohort: 125 used simple running skin closure technique, and 134 used the subcuticular skin closure. Patients were found to not have any difference in rate of dehiscence or overall wound complications based on gender, age, location of port, or use of steroids or chemotherapy within 1week of port placement. When compared, only 1 case (0.80%) in the simple running group vs 10 cases (7.46%) in the subcuticular group experienced a wound dehiscence [unadjusted OR=14.07 (1.69, 116.99) p=0.0144]. When comparing overall wound complications the simple running group had 3 (2.4%) versus 12 (8.96%) in the subcuticular group [unadjusted OR=4.78 (1.27, 17.94) p=0.0203]. When adjusting for port-number both dehiscence and overall wound complications remained statistically significant. We conclude that the simple running skin closure for chemo-port placement in children has superior outcomes in regards to prevention of dehiscence and overall wound related complications when compared to the subcuticular technique. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Simplified technique for placement of a medical-grade adhesive silicone denture liner.

    Science.gov (United States)

    Duncan, J D; Caswell, C W; Rommerdale, E H

    1985-10-01

    A simplified technique for placement and care of a long-term resilient liner has been described. The procedure can be accomplished in the dental office without an investing or flasking procedure. Finishing is easily accomplished, and the retention of the liner is secure from peeling or separating. Disadvantages include the necessity of having a satisfactory denture border prior to the procedure and the tendency of RTV silicones to develop fungal growth over a period of time without proper care.

  15. Model-Based Throttle Control using Static Compensators and Pole Placement Commande des gaz basée sur un modèle utilisant des compensateurs statiques et un placement de pôles

    Directory of Open Access Journals (Sweden)

    Thomasson A.

    2011-10-01

    Full Text Available In modern spark ignited engines, the throttle is controlled by the Electronic Control Unit (ECU, which gives the ECU direct control of the air flow and thereby the engine torque. This puts high demands on the speed and accuracy of the controller that positions the throttle plate. The throttle control problem is complicated by two strong nonlinear effects, friction and limp-home torque. This paper proposes the use of two, simultaneously active, static compensators to counter these effects and approximately linearize the system. A PID controller is designed for the linearized system, where pole placement is applied to design the PD controller and a gain scheduled I-part is added for robustness against model errors. A systematic procedure for generating compensator and controller parameters from open loop experiments is also developed. The controller performance is evaluated both in simulation, on a throttle control benchmark problem, and experimentally. A robustness investigation pointed out that the limp-home position is an important parameter for the controller performance, this is emphasized by the deviations found in experiments. The proposed method for parameter identification achieves the desired accuracy. Au sein des moteurs à allumage commandé modernes, les gaz sont régulés par le boîtier de commande électronique (ECU; Electronic Control Unit, qui permet la régulation directe par l’ECU du flux d’air et ainsi du couple moteur. Cela conduit à des exigences élevées quant à la vitesse et à la précision du régulateur qui positionne le papillon des gaz. Le problème de commande des gaz est compliqué par deux forts effets non linéaires, le frottement et le couple de mode de secours (“limp-home”. Cet article propose l’utilisation de deux compensateurs statiques, actifs simultanément, pour contrer ces effets et linéariser approximativement le système. Un régulateur PID est conçu pour le système linéarisé, où un

  16. Deep percolation in greenhouse-cultivated celery using the technique of subsurface film strips placement

    Directory of Open Access Journals (Sweden)

    Zhida Du

    2014-05-01

    Full Text Available To reduce the deep percolation during greenhouse vegetable cultivation, the technique of subsurface film strips placement was tested. Four treatments with two kinds of cross-sections (flat and U-shaped and two different spacings (10 cm and 40 cm of subsurface film strips were arranged in a greenhouse before planting celery. At the same time, a non-film treatment was arranged for comparison. Soil water content was measured and irrigation time was adjusted according to the soil water content. Evapotranspiration of celery during growth was calculated by the method of energy balance and the deep percolation was calculated by the equation of water balance. Deep percolation was reduced in all experimental treatments. Greater reduction in deep percolation was observed when using U-shaped cross-section strips compared with that using the flat cross-section strips. In addition, greater reduction in deep percolation was observed when the spacing between the film strips was smaller. The results of this test showed that the technique of subsurface film strips placement can reduce deep percolation and conserve irrigation water for greenhouse vegetables cultivation. However, the optimal layout variables for the use of the technique of subsurface film strips placement need further experimental and numerical analysis.

  17. Fracture Resistance of Premolars Restored by Various Types and Placement Techniques of Resin Composites

    Directory of Open Access Journals (Sweden)

    Horieh Moosavi

    2012-01-01

    Full Text Available To verify the fracture resistance of premolars with mesioocclusodistal preparations restored by different resin composites and placement techniques. Sixty premolars were randomly divided into two groups based on type of composite resin: Filtek P60 or Nulite F, and then each group was separated into three subgroups: bulk, centripetal, and fiber insert according to the type of placement method (n=10. Single-bond adhesive system was used as composite bonding according to the manufacturer's instructions. Specimens were restored in Groups 1, 2, and 3 with Filtek P60 and in Groups 4, 5, and 6 with Nulite F. After being stored 24 hours at 37∘C, a 4 mm diameter steel sphere in a universal testing machine was applied on tooth buccal and lingual cusps at a cross-head speed of 5 mm/min until fracture occurred. Groups 3 and 6 showed higher fracture resistance than Groups 1, 2, 4, and 5. Among the placement techniques, the fiber insert method had a significant effect, but the type of composite was ineffective. The insertion technique in contrast to the type of material had a significant influence on the fracture resistance of premolar teeth.

  18. Intrasinusal locking technique: a novel use of the ring block technique at sinus perforations for simultaneous implant placement.

    Science.gov (United States)

    Sindel, A; Özarslan, M M; Özalp, Ö

    2018-04-01

    Ten patients who underwent sinus lift surgery with simultaneous implant placement using the intrasinusal locking technique were evaluated retrospectively. All patients were scheduled for sinus floor elevation procedures with simultaneous implant placement. Schneiderian membrane perforation occurred during the lifting procedure, and conventional methods failed to repair the perforation. Therefore, an autogenous bone ring was placed at the base of the maxillary sinus and was locked to the alveolar crest with a dental implant. Marginal resorption around the dental implants was measured on panoramic radiographs. Prosthetic rehabilitation was performed at 6 months postoperative. The overall survival rate of the implants over a mean follow-up of 24.3 months was 90%. One case failed due to resorption of the alveolar crest around the implant as a result of infection; the implant and the adjacent ring were removed at 1 month postoperative. At the time of writing, the nine implants placed using the documented technique continue to function well, without any signs of peri-implant disease. The proposed approach allows for simultaneous dental implant placement in the extremely atrophic maxilla, even if there is extensive perforation of the Schneiderian membrane. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Socket Shield Technique for Implant Placement in the Esthetic Zone: A Case Report.

    Science.gov (United States)

    Petsch, Matthias; Spies, Benedikt; Kohal, Ralf-Joachim

    Improvements in implant design, placement protocols, and sequences for reconstruction in the anterior region have enabled clinicians to provide their patients with esthetically acceptable results. Yet from a clinical standpoint, the predictable preservation of the peri-implant soft tissue remains challenging and tissue grafting is often necessary to compensate for ridge contour changes in postextraction sites. In animal and clinical studies, the socket shield technique has shown its potential to prevent resorption of buccal tissues. This 24-month follow-up case report presents a 47-year-old patient with a failing maxillary incisor replaced with an immediately placed single implant in conjunction with the socket shield technique.

  20. [Implant placement in the aesthetic zone: the socket-shield-technique].

    Science.gov (United States)

    Lagas, L J; Pepplinkhuizen, J J F A A; Bergé, S J; Meijer, G J

    2015-01-01

    Following the extraction of an incisor in the maxilla, resorption of the -alveolar bone always occurs, especially on the buccal side. This often indicates that in the buccocervical area, insufficient bone is present to cover the dental implant. One treatment option is to carry out a bone transplant on the buccal side prior to or during the placement of the implant. An alternative way of supporting the buccocervical gingival is to leave the buccal part of the radixin situ, the so-called socket-shield technique. The results of this treatment for 16 consecutive patients were evaluated and revealed that the socket-shield technique produces good treatment results.

  1. The blind pushing technique for peripherally inserted central catheter placement through brachial vein puncture.

    Science.gov (United States)

    Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol

    2018-03-01

    The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (<120 seconds) differed significantly between brachial vein and nonbrachial vein access (P = .001). There was no statistically significant difference between brachial vein and

  2. One-piece implants: placement timing, surgical technique, loading protocol, and marginal bone loss.

    Science.gov (United States)

    Prithviraj, D R; Gupta, Vikas; Muley, Ninad; Sandhu, Pushpinder

    2013-04-01

    Osseointegration being an accepted and well-documented concept, attention is now directed towards simplification of the mechanical design of implants and towards achieving biomechanical success. The aim of this literature review is to provide an overview of the one-piece implant, with its advantages and disadvantages over a conventional two-piece implant. The PubMed database was searched in the English language using the keywords one-piece implant, single-piece implant, single-stage implant surgery, and two-piece implant. Articles were selected on the basis of whether they had sufficient information related to placement timing, surgical procedure used, loading protocol, follow-up periods, marginal bone loss, and implant success rates of one-piece implants. For inclusion, a study group must have had a minimum of 30 one-piece implants followed for at least 1 year. Nineteen articles were subjected to the selection criteria. Out of 19 clinical trials only 11 met the selection criteria. Five parameters were taken into consideration for studying one-piece implants: placement timing, surgical technique, loading protocol, marginal bone loss, and implant survival rate. The data from the identified studies were tabulated according to these parameters and discussed. Delayed placement of one-piece implants is more commonly practiced than extraction and immediate placement. Most surgeons prefer surgeries using flaps as compared to flapless surgeries, and in most cases, one-piece implants were loaded immediately. Limited literature reveals both positive and negative results regarding the effect of a one-piece implant system on surrounding hard and soft tissues. © 2012 by the American College of Prosthodontists.

  3. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.

    Science.gov (United States)

    Yang, Xu; Wu, Qinfen; Lai, Chin-Hui; Wang, Xin

    2017-10-01

    We present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome. The patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1days (range, 2-12days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up. No patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29). The modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Transcrestal sinus lift and implant placement using the sinus balloon technique

    Science.gov (United States)

    Galán-Gil, Sónnica; Carrillo-García, Celia; Peñarrocha-Diago, David; Peñarrocha-Diago, Miguel

    2012-01-01

    Objective: A description is made of transcrestal sinus lift using the sinus balloon technique, evaluating the bone height achieved and implant success one year after prosthetic loading. Material and method: Between January and July 2007, transcrestal sinus lift using the sinus balloon technique for dental implant placement was carried out in 6 patients. A panoramic X-ray study and maxillary computed tomography scan were carried out before the operation, in order to discard possible sinus pathology. During the intervention, the integrity of the sinus membrane was evaluated using a Medi Pack Pal endoscope (Farol Store and Co., Tuttlingen, Germany), and the intraoperative complications were analyzed. The dental implants were placed in the same surgical step in the presence of 3 mm or more of residual bone. Following the operation, panoramic X-rays were used to assess the bone height gained. One year after prosthetic loading, the implant success rate was determined based on the criteria of Buser. Results: One patient was excluded due to Schneider’s membrane perforation as confirmed by endoscopy. Trans-crestal sinus lift was carried out in 5 males with a mean age of 41.6 years (range 27-51), without antecedents of sinus disease. There were no intraoperative complications. In four patients the implants were placed simultaneous to sinus lift, while in another case implant placement was postponed due to insufficient remaining bone height. The mean gain in height after the operation was 8.7 mm. One year after prosthetic loading, the implant success rate was 100%. Conclusions: Transcrestal sinus lift using the sinus balloon technique is a minimally invasive procedure. In 5 patients the bone height gained proved sufficient to allow implant placement even in the presence of 3 mm of residual bone. Key words: Sinus lift, balloon, sinus complications. PMID:22157670

  5. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  6. Endoscopically assisted nasojejunal feeding tube placement: technique and results in five dogs.

    Science.gov (United States)

    Campbell, Scott Ayers; Daley, Catherine A

    2011-01-01

    Interest in noninvasive feeding tube placement in companion animals led to the adaption of a human technique utilizing endoscopy to place nasojejunal feeding tubes. Data from medical records in which nasojejunal feeding tubes were attempted were reviewed. Feeding tubes were attempted and successfully placed in five dogs within a median of 35 min. Feeding tubes remained in place for approximately 7 days. Complications included facial irritation (5/5), sneezing (5/5), fractured facial sutures (4/5), vomiting (3/5), diarrhea (3/5), crimping of feeding tube (3/5), regurgitation (1/5), epistaxis (1/5), clogging of the feeding tube (2/5), and oral migration with premature removal of the feeding tube (1/5). The deployment technique used in this study was found to be cumbersome. Despite minor complications, endoscopy can be used to rapidly and accurately place nasoenteric feeding devices.

  7. An element search ant colony technique for solving virtual machine placement problem

    Science.gov (United States)

    Srija, J.; Rani John, Rose; Kanaga, Grace Mary, Dr.

    2017-09-01

    The data centres in the cloud environment play a key role in providing infrastructure for ubiquitous computing, pervasive computing, mobile computing etc. This computing technique tries to utilize the available resources in order to provide services. Hence maintaining the resource utilization without wastage of power consumption has become a challenging task for the researchers. In this paper we propose the direct guidance ant colony system for effective mapping of virtual machines to the physical machine with maximal resource utilization and minimal power consumption. The proposed algorithm has been compared with the existing ant colony approach which is involved in solving virtual machine placement problem and thus the proposed algorithm proves to provide better result than the existing technique.

  8. The periumbilical approach in ventriculoperitoneal shunt placement: technique and long-term results.

    Science.gov (United States)

    Recinos, Pablo F; Pindrik, Jonathan A; Bedri, Mazen I; Ahn, Edward S; Jallo, George I; Recinos, Violette Renard

    2013-05-01

    low infection rates, and has cosmetically appealing results. It may be considered as an alternative option to standard VP shunt placement techniques.

  9. Effectiveness of different final irrigation techniques and placement of endodontic sealer into dentinal tubules

    Directory of Open Access Journals (Sweden)

    Kauhanna Vianna de Oliveira

    2017-12-01

    Full Text Available Abstract: The aim of this study was to compare two irrigation techniques and four devices for endodontic sealer placement into the dentinal tubules. Ninety-nine single-rooted human teeth were instrumented and allocated to either the control (CO (n=11 or experimental groups according to the irrigation method: syringe and NaveTip needle (NT (n=44, and EndoActivator (EA (n=44. These groups were subdivided according to sealer placement into K-File (KF, lentulo spiral (LS, Easy Clean (EC, and EndoActivator (EA subgroups. Moreover, the distances of 5 mm and 2 mm from the apex were analyzed. The teeth were obturated with AH Plus and GuttaCore X3. Analyses were performed by scanning electron microscopy associated to cathodoluminescence. The percentage and maximum depth of sealer penetration were measured. Data were evaluated by three-way analysis of variance (ANOVA and Games-Howell test (p<0.05. EA was superior to NT in percentage of sealer penetration. EC was significantly superior to EA (subgroup for sealer penetration, and both improved the percentage of sealer penetration when compared to LS. Better sealer penetration was observed at the distance of 5 mm from the apex. Sealer penetration into the dentinal tubules was significantly improved by sonic irrigant activation.

  10. Effectiveness of different final irrigation techniques and placement of endodontic sealer into dentinal tubules.

    Science.gov (United States)

    Oliveira, Kauhanna Vianna de; Silva, Bruno Marques da; Leonardi, Denise Piotto; Crozeta, Bruno Monguilhott; Sousa-Neto, Manoel Damião de; Baratto-Filho, Flares; Gabardo, Marilisa Carneiro Leão

    2017-12-18

    The aim of this study was to compare two irrigation techniques and four devices for endodontic sealer placement into the dentinal tubules. Ninety-nine single-rooted human teeth were instrumented and allocated to either the control (CO) (n=11) or experimental groups according to the irrigation method: syringe and NaveTip needle (NT) (n=44), and EndoActivator (EA) (n=44). These groups were subdivided according to sealer placement into K-File (KF), lentulo spiral (LS), Easy Clean (EC), and EndoActivator (EA) subgroups. Moreover, the distances of 5 mm and 2 mm from the apex were analyzed. The teeth were obturated with AH Plus and GuttaCore X3. Analyses were performed by scanning electron microscopy associated to cathodoluminescence. The percentage and maximum depth of sealer penetration were measured. Data were evaluated by three-way analysis of variance (ANOVA) and Games-Howell test (ppenetration. EC was significantly superior to EA (subgroup) for sealer penetration, and both improved the percentage of sealer penetration when compared to LS. Better sealer penetration was observed at the distance of 5 mm from the apex. Sealer penetration into the dentinal tubules was significantly improved by sonic irrigant activation.

  11. Comparison of three different sealer placement techniques: An In vitro confocal laser microscopic study

    Directory of Open Access Journals (Sweden)

    Avoy Kumar Dash

    2017-01-01

    Full Text Available Introduction: Three-dimensional obturation of the root canal system is the final objective of root canal therapy. Greater penetration of sealer in root dentine lesser will be the voids at the dentine–sealer interface. Hence, analysis of the dentin/sealer interface allows the determination of a filling technique which could obturate the root canals with least gaps and voids. Therefore, the aim of this study is to compare the depth and percentage of sealer penetration into root dentin using three different root canal sealer placement techniques under confocal laser scanning microscope. Materials and Methods: Thirty single-rooted teeth were selected and prepared. Adseal sealer (Meta Biomed, South Korea was mixed with Rhodamine B dye and applied using lentulo spiral (Dentsply Maillefer, USA as Group 1, bidirectional spiral (EZ-Fill– EDS, USA as Group 2, and ultrasonic endodontic tip (Sonofile– Dentsply Tulsa, USA as Group 3. Canals were then obturated with gutta-percha. The roots were sectioned at the 3 and 6-mm levels from the apical foramen and examined under confocal laser microscope. Results: Maximum mean depth and percentage of sealer penetration were observed for Group 1 and minimum for Group 3. Furthermore, statistical significant differences among Group 1 and Group 3 were found at 6-mm level and among Group 2 and Group 3 were found at 3-mm level (P < 0.05. Conclusion: The depth and percentage of sealer penetration of sealer are influenced by the type of placement technique and by the root canal level, with penetration decreasing apically. Lentulo spiral has shown better penetration of sealer than the bidirectional file and ultrasonics.

  12. Facet Joint Violation During Percutaneous Pedicle Screw Placement: A Comparison of Two Techniques.

    Science.gov (United States)

    Tannous, Oliver; Jazini, Ehsan; Weir, Tristan B; Banagan, Kelley E; Koh, Eugene Y; Greg Anderson, D; Gelb, Daniel E; Ludwig, Steven C

    2017-08-01

    A comparative study of facet joint violation (FJV) using two percutaneous surgical techniques. To compare the rate of iatrogenic FJV and medial pedicle wall breach between two methods of percutaneous pedicle screw instrumentation in the thoracic and lumbar spine. Variable iatrogenic damage to the facet joints has been reported to occur with percutaneous pedicle screw techniques, compared with the open approach, which has been associated with adjacent segment disease. Technical variations of percutaneous pedicle screw placement may pose different risks to the facet joint. Attending spine surgeons percutaneously placed pedicle screws in seven human cadaveric spines from T2 to L5. At each level, screws were instrumented on one side using the 9 or 3 o'clock reference point of the pedicle on the posteroanterior view with a lateral-to-medial trajectory (LMT) and on the contralateral side using the center of the pedicle with an owl's eye trajectory (OET). Postoperative screw placement was assessed with computed tomography and then open cadaveric dissection. Outcome measures included FJV and medial pedicle wall breach. Overall, 17 of 105 screws placed with an LMT versus 49 of 105 screws placed with an OET violated or abutted the facet joint (P L1), and lumbar (L2-L5) levels (P = 0.003, 0.035, and 0.018, respectively). Medial pedicle wall breach occurred with 11 LMT screws and seven OET screws (P = 0.077), and no breach was considered critical. A significantly higher FJV rate was observed using the OET versus the LMT in the thoracic, thoracolumbar, and lumbar spine. No statistically significant differences in medial pedicle wall breach occurred between the techniques. Thus, the LMT of minimally invasive pedicle screw fixation may reduce iatrogenic damage to the facet joints. 3.

  13. A Scapholunate Ligament-Sparing Technique Utilizing the Medial Femoral Condyle Corticocancellous Free Flap to Reconstruct Scaphoid Nonunions With Proximal Pole Avascular Necrosis.

    Science.gov (United States)

    Kazmers, Nikolas H; Thibaudeau, Stephanie; Levin, L Scott

    2016-09-01

    This article demonstrates a technique for the treatment of scaphoid fracture waist and proximal pole nonunions with avascular necrosis using a free vascularized medial femoral condyle flap. We present our surgical technique and representative case examples in which the scapholunate ligament, a key structure required to preserve carpal kinematics, is spared. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Performance and Advanced Data Placement Techniques with Ceph's Distributed Storage System

    Science.gov (United States)

    Poat, M. D.; Lauret, J.

    2016-10-01

    The STAR online computing environment is a demanding concentrated multipurpose compute system with the objective to obtain maximum throughput with process concurrency. Motivation for extending the STAR online compute farm from a simple job processing tool for data taking, into a multipurpose resource equipped with a large storage system would lead any dedicated resources to become an extremely efficient and an attractive multi-purpose facility. To achieve this goal, our compute farm is using the Ceph distributed storage system which has proven to be an agile solution due to its effective POSIX interface and excelling its object storage with IO concurrency. With this we have taken our cluster one step further in terms of IO performance by investigating and leveraging new technologies and key features of Ceph. With the acquisition of a 10Gb backbone network we have ensured to eliminate the network as a limitation. With further acquisition of large fast drives (1TB SSDs) we will show how one can customize the data placement options Ceph has to offer such as primary affinity, mounting OSD journals on SSDs, and Cache Tiering along with non-Ceph related local disk caching techniques. We will discuss the latest performance results along with the expected results by using each technique. We hope this paper will serve the community's interest for the Ceph distributed storage solution.

  15. Novel Technique for Hepatic Fiducial Marker Placement for Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Jarraya, Hajer; Chalayer, Chloé; Tresch, Emmanuelle; Bonodeau, Francois; Lacornerie, Thomas; Mirabel, Xavier; Boulanger, Thomas; Taieb, Sophie; Kramar, Andrew; Lartigau, Eric; Ceugnart, Luc

    2014-01-01

    Purpose: To report experience with fiducial marker insertion and describe an advantageous, novel technique for fiducial placement in the liver for stereotactic body radiation therapy with respiratory tracking. Methods and Materials: We implanted 1444 fiducials (single: 834; linked: 610) in 328 patients with 424 hepatic lesions. Two methods of implantation were compared: the standard method (631 single fiducials) performed on 153 patients from May 2007 to May 2010, and the cube method (813 fiducials: 610 linked/203 single) applied to 175 patients from April 2010 to March 2013. The standard method involved implanting a single marker at a time. The novel technique entailed implanting 2 pairs of linked markers when possible in a way to occupy the perpendicular edges of a cube containing the tumor inside. Results: Mean duration of the cube method was shorter than the standard method (46 vs 61 minutes; P<.0001). Median numbers of skin and subcapsular entries were significantly smaller with the cube method (2 vs 4, P<.0001, and 2 vs 4, P<.0001, respectively). The rate of overall complications (total, major, and minor) was significantly lower in the cube method group compared with the standard method group (5.7% vs 13.7%; P=.013). Major complications occurred while using single markers only. The success rate was 98.9% for the cube method and 99.3% for the standard method. Conclusions: We propose a new technique of hepatic fiducial implantation that makes use of linked fiducials and involves fewer skin entries and shorter time of implantation. The technique is less complication-prone and is migration-resistant

  16. Chest Radiograph Measurement Technique Facilitates Accurate Bedside Peripherally Inserted Central Catheter Placement in Children.

    Science.gov (United States)

    Ramamurthi, Aishu; Chick, Jeffrey Forris Beecham; Srinivasa, Rajiv N; Hage, Anthony N; Grove, Jason J; Gemmete, Joseph J; Johnson, Timothy D; Srinivasa, Ravi N

    2018-03-01

    To report the chest radiograph measurement technique for placing bedside peripherally inserted central catheters (PICCs). Two hundred and thirty-two consecutive pediatric patients, mean age of 56.3 months (range: 0-203 months), underwent PICC placement from January 2015 to May 2017 (28 months) with a total of 232 PICCs placed. Measurements were taken from the cavoatrial junction to clavicle, clavicle to medial margin of mid-humeral head, and medial margin of mid-humeral head to mid-humerus. The difference between total radiographic measured length and actual PICC length was then calculated, and the percent difference (from actual cut length) was recorded. An equivalence test was performed using the two, one-sided test method. Mean ± standard deviation cavoatrial junction to clavicle length was 5.29 ± 2.20 cm (range: 2.1-12.6 cm). Mean clavicle to shoulder length was 8.20 ± 3.59 cm (range: 3.23-19.06 cm). Mean shoulder to mid-humerus length was 7.88 ± 3.87 cm (range: 2.01-16.8 cm). Mean total radiographic measured length was 21.37 ± 9.19 cm (range: 7.42-43.6 cm). Mean actual cut PICC length was 20.64 ± 8.72 cm (range: 8.5-44 cm). The mean difference between predicted, or total radiographic measured length, and actual cut PICC length was 0.73 ± 2.51 (range: - 5.42-8.60 cm). The mean percent difference was 4.07 ± 12.65% (range: - 23.84-47.80%). An equivalence test rejected the null hypothesis of the true percent difference greater/less than ± 6.67% with a p value of 0.002. The chest radiograph measurement technique is an accurate method to determine catheter length for PICC placement at bedside in the pediatric population.

  17. Comparison of metaheuristic techniques to determine optimal placement of biomass power plants

    International Nuclear Information System (INIS)

    Reche-Lopez, P.; Ruiz-Reyes, N.; Garcia Galan, S.; Jurado, F.

    2009-01-01

    This paper deals with the application and comparison of several metaheuristic techniques to optimize the placement and supply area of biomass-fueled power plants. Both, trajectory and population-based methods are applied for our goal. In particular, two well-known trajectory method, such as Simulated Annealing (SA) and Tabu Search (TS), and two commonly used population-based methods, such as Genetic Algorithms (GA) and Particle Swarm Optimization (PSO) are hereby considered. In addition, a new binary PSO algorithm has been proposed, which incorporates an inertia weight factor, like the classical continuous approach. The fitness function for the metaheuristics is the profitability index, defined as the ratio between the net present value and the initial investment. In this work, forest residues are considered as biomass source, and the problem constraints are: the generation system must be located inside the supply area, and its maximum electric power is 5 MW. The comparative results obtained by all considered metaheuristics are discussed. Random walk has also been assessed for the problem we deal with.

  18. Comparison of metaheuristic techniques to determine optimal placement of biomass power plants

    Energy Technology Data Exchange (ETDEWEB)

    Reche-Lopez, P.; Ruiz-Reyes, N.; Garcia Galan, S. [Telecommunication Engineering Department, University of Jaen Polytechnic School, C/ Alfonso X el Sabio 28, 23700 Linares, Jaen (Spain); Jurado, F. [Electrical Engineering Department, University of Jaen Polytechnic School, C/ Alfonso X el Sabio 28, 23700 Linares, Jaen (Spain)

    2009-08-15

    This paper deals with the application and comparison of several metaheuristic techniques to optimize the placement and supply area of biomass-fueled power plants. Both, trajectory and population-based methods are applied for our goal. In particular, two well-known trajectory method, such as Simulated Annealing (SA) and Tabu Search (TS), and two commonly used population-based methods, such as Genetic Algorithms (GA) and Particle Swarm Optimization (PSO) are hereby considered. In addition, a new binary PSO algorithm has been proposed, which incorporates an inertia weight factor, like the classical continuous approach. The fitness function for the metaheuristics is the profitability index, defined as the ratio between the net present value and the initial investment. In this work, forest residues are considered as biomass source, and the problem constraints are: the generation system must be located inside the supply area, and its maximum electric power is 5 MW. The comparative results obtained by all considered metaheuristics are discussed. Random walk has also been assessed for the problem we deal with. (author)

  19. Placement of replace select Ti-Unite-coated type implants using a combination of immediate and submerge techniques after tooth extraction

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-06-01

    Full Text Available The high success rate of immediate implant placement both in the anterior and posterior regions were reported by many authors, therefore applying this techniques can be considered as a safe surgical procedure and minimizing the dental office visit for patient satisfaction. This paper reports the outcome of immediate placement of implants following extraction of anterior maxillary teeth. Combination technique of immediate and submerge implant placements including bone grafting procedure were used. Four implants with TiUnite surface type were placed immediately in two patients with the short-term result indicated that this technique may serve as a simple and safe procedure for immediate implant placement. It was concluded that immediate implant placement technique combined with TiUnite implant surface was successful in treating region directly after tooth extraction therefore this technique can be use as an alternative surgical method for dental implant rehabilitation.

  20. Esthetic consideration for alveolar socket preservation prior to implant placement: description of a technique and 80-case series report.

    Science.gov (United States)

    Kutkut, Ahmad; Andreana, Sebastiano; Monaco, Edward

    2012-01-01

    An esthetic restoration supported by dental implant rehabilitation is a major challenge to restorative dentists. The ultimate goal of a dental implant is to restore missing or extracted teeth by placing implants in anatomically, esthetically, and long-term functional restorations. Alveolar ridge preservation and site enhancement following tooth extraction has a major impact on the hard and soft tissue volume. Extraction socket preservation is technique sensitive, not 100% successful, and at times unpredictable. Current techniques may delay surgical implant placement for a few months, and the quality of new bone regeneration is questionable. The aim of this report was to describe a minimally traumatic extraction socket preservation technique using different types of bone graft as a preserver prior to implant placement applied for 80 consecutive cases.

  1. A Split-Mouth Design Comparison for Lateral and Crestal Sinus Lift Techniques with Dental Implants Placements: Short Communication.

    Science.gov (United States)

    Al-Almaie, Saad; Kavarodi, Abdul Majeed; Alorf, Ali; Alzahrani, Saeed

    2017-01-01

    The objective of this study is to compare and evaluate the effectiveness of implant placement and patient appraisal for two sinus lift techniques using both crestal and lateral techniques for bilateral sinus left in a split-mouth design. All implants were successfully osseointegrated without any clinical complications or peri-implant radiolucency during the follow-up period of maximum 3 years. In terms of outcomes postoperative vertigo showed to be a major concern with the crestal approach, this approach is preferred over the lateral technique because of the reduced time required for the procedure and because it is less invasive. Most patients preferred the crestal approach over the lateral approach due to the delay in implant placement.

  2. Arthroscopically-assisted Latarjet: an easy and reproducible technique for improving the accuracy of graft and screw placement.

    Science.gov (United States)

    Taverna, Ettore; Guarrella, Vincenzo; Cartolari, Roberto; Ufenast, Henri; Broffoni, Laura; Barea, Christophe; Garavaglia, Guido

    2018-04-01

    The effectiveness of the Latarjet largely depends on accurate graft placement, as well as on proper position and direction of the screws. We present our technique for an arthroscopically-assisted Latarjet comparing radiological results with the open technique. We retrospectively reviewed the postoperative computed tomography scans of 38 patients who underwent a Latarjet procedure. For 16 patients, the procedure was performed with the open technique and, for 22 patients, it was performed using an arthroscopically-assisted technique. An independent radiologist evaluated graft and hardware position, as well as graft integration or resorption. Postoperative complications were also documented. The graft was correctly placed in only 18.8% of cases in the open group and 72.7% of cases in the arthroscopically-assisted group. There were no postoperative complications in the arthroscopically-assisted group, whereas one patient had a recurrence and two required hardware removal in the open group. The Latarjet procedure is a challenging procedure for which a key point is the correct placement of the coracoid graft onto the glenoid neck and correct position of the screws. The present study substantiates a clear benefit for the use of a guide with an arthroscopically-assisted technique in terms of graft and hardware placement. At short-term follow-up, there appears to be a benefit for graft integration and avoidance of resorption.

  3. Analog integrated circuit design automation placement, routing and parasitic extraction techniques

    CERN Document Server

    Martins, Ricardo; Horta, Nuno

    2017-01-01

    This book introduces readers to a variety of tools for analog layout design automation. After discussing the placement and routing problem in electronic design automation (EDA), the authors overview a variety of automatic layout generation tools, as well as the most recent advances in analog layout-aware circuit sizing. The discussion includes different methods for automatic placement (a template-based Placer and an optimization-based Placer), a fully-automatic Router and an empirical-based Parasitic Extractor. The concepts and algorithms of all the modules are thoroughly described, enabling readers to reproduce the methodologies, improve the quality of their designs, or use them as starting point for a new tool. All the methods described are applied to practical examples for a 130nm design process, as well as placement and routing benchmark sets. Introduces readers to hierarchical combination of Pareto fronts of placements; Presents electromigration-aware routing with multilayer multiport terminal structures...

  4. Comparison of Mechanical and Indirect Ultrasonic Placement Technique on Mineral Trioxide Aggregate Retrofill Density in Simulated Root-end Surgery.

    Science.gov (United States)

    Friedl, Christopher C; Williamson, Anne E; Dawson, Deborah V; Gomez, Manuel R; Liu, Wei

    2016-04-01

    The objective of this study was to evaluate the density of mineral trioxide aggregate (MTA) root-end filling placed by either manual condensation or manual condensation with indirect ultrasonic activation under simulated root-end surgery conditions in vitro. Extracted human molar teeth were obtained and sectioned to provide single-rooted samples (n = 50). Roots were instrumented to a size of 40 with a .04 taper and obturated with a warm vertical technique. The coronal end of each root was embedded in resin. A root-end resection and root-end preparation were completed on each root. Samples were randomly assigned to receive root-end fillings with ProRoot MTA (Dentsply, Tulsa, OK) by 1 of 2 techniques: manual condensation alone (group M, n = 25) or manual condensation with indirect ultrasonic activation (group U, n = 25). MTA was placed incrementally to the level of the root end using the enumerated technique. Samples were weighed immediately before and after filling placement. MTA was removed from all samples so as not to change the root-end preparation, rinsed, and dried. Each sample then underwent MTA placement by the opposite technique, and weight was again measured immediately before and after MTA placement. MTA filling weights for each technique were analyzed statistically using a technique for repeated measures analysis. Statistical analysis was conducted to account for any carryover or order effects. After adjustment for carryover effects, it was found that regardless of the order of placement, the mean fill weight of MTA produced by the indirect ultrasonic method was on average 4.42 mg heavier than that produced by manual condensation alone. This result was statistically significant (P MTA root-end fillings was shown to produce a filling that was significantly denser than MTA placed by manual condensation alone. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Analyses of the Short Periodical Part of the Spectrum of Pole Coordinate Variations Determined by the Astrometric and Laser Technique

    Science.gov (United States)

    Kołaczek, B.; Kosek, W.; Galas, R.

    Series of BIH astrometric (BIH-ASTR) pole coordinates and of CSR LAGEOS laser ranging (CSR-LALAR) pole coordinates determined in the MERIT Campaign in the years 1972 - 1986, 1983 - 1986, respectively, have been filtered by different band pass filters consisting of the law pass Gauss filter and of the high pass Butterworth filter. Filtered residuals were analysed by the MESA-Maximum Entropy Spectra Analysis and by the Ormsby narrow band pass filters in order to find numerically modeled signals approximating these residuals in the best way.

  6. A step-by-step oncoplastic breast conservation surgical atlas of reproducible dissection techniques and anatomically ideal incision placement.

    Science.gov (United States)

    Mitchell, Sunny D

    2017-10-01

    To develop an atlas for oncoplastic surgery (OPS) with template dissection techniques via anatomically ideal incisions for breast conservation surgery. The evolution of breast conservation techniques has evolved from placing an incision directly over the lesion to the incorporation of a thoughtful decision making process utilizing oncoplastic surgical (OPS) techniques to combining OPS with incision placement in anatomically advantageous sites. The high survival rates of breast cancer and effect of breast surgery on quality of life reinforce emphasis of optimal oncologic as well as aesthetic outcome. OPS results in greater patient satisfaction, fewer surgeries, and is oncologically safe. Today's breast surgeon is tasked with optimizing both oncologic and aesthetic outcomes. Presentation of reproducible dissection techniques and incision placement strategies to afford surgeons a step-by-step approach of OPS via anatomically ideal incisions in breast conservation surgery. Demonstration of reproducible techniques to facilitate the decision making process of optimal breast conservation surgery, eliminate knowledge gaps for surgeons, optimize outcome for individuals undergoing breast conservation surgery, and decrease disparity of care. Adoption of OPS techniques utilizing an anatomically ideal incision in breast conservation surgery is a feasible and reproducible practice for breast surgeons. Application of these techniques results in maintained optimal shape, size, and contour without the typical overlying skin envelope scars. OPS techniques performed under the skin envelope result in expected OPS oncologic and aesthetic outcomes with the addition of the resulting scar(s) in anatomically discrete position(s).

  7. Special considerations for placement of an inflatable penile prosthesis for the patient with Peyronie's disease: techniques and patient preference

    Directory of Open Access Journals (Sweden)

    Lyons MD

    2015-07-01

    Full Text Available Matthew D Lyons, Culley C Carson III, Robert M Coward Department of Urology, University of North Carolina, Chapel Hill, NC, USA Abstract: Placement of an inflatable penile prosthesis (IPP is the mainstay of surgical treatment for patients with Peyronie's disease (PD and concomitant medication-refractory erectile dysfunction. Special considerations and adjunctive surgical techniques during the IPP procedure are often required for patients with PD to improve residual penile curvature, as well as postoperative penile length. The surgical outcomes and various adjunctive techniques are not significantly different from one another, and selection of the appropriate technique must be tailored to patient-specific factors including the extent of the deformity, the degree of penile shortening, and preoperative patient expectations. The aims of this review were to assess the current literature on published outcomes and surgical techniques involving IPP placement in the treatment of PD. Patient satisfaction and preferences are reported, along with the description and patient selection for surgical techniques that include manual penile modeling, management of refractory curvature with concurrent plication, and correction of severe residual curvature and penile shortening with tunica release and plaque incision and grafting. A thorough description of the available techniques and their associated outcomes may help guide surgeons to the most appropriate choice for their patients. Keywords: Peyronie's disease, outcomes, inflatable penile prosthesis, patient expectation, patient satisfaction 

  8. Modeling FWM and impairments aware amplifiers placement technique for an optical MAN/WAN: Inline amplifiers case

    Science.gov (United States)

    Singh, Gurpreet; Singh, Maninder Lal

    2015-08-01

    A new four wave mixing (FWM) model for an optical network with amplifiers and a comparative analysis among three proposed amplifiers placement techniques have been presented in this paper. The FWM model is validated with the experimental measured data. The novelty of this model is its uniqueness that on direct substitutions of network parameters like length, it works even for unequal inter amplifier separations. The novelty of the analysis done among three schemes is that it presents fair choice of amplifiers placement methods for varied total system length. The appropriateness of these three schemes has been analyzed on the basis of critical system length, critical number of amplifiers and critical bit error rate (10-9) in presence of four wave mixing (FWM) and amplified spontaneous emission noise (ASE). The implementation of analysis done has been given with the help of an example of a regenerative metropolitan area network (MAN). The results suggest that the decreasing fiber section scheme should be avoided for placements of amplifiers and schemes IUFS and EFS shows their importance interchangeably for different set of parameters.

  9. [Short term effect of multiple stents parallel placement and reconstruction technique for the treatment of giant fusiform vertebrobasilar dissecting aneurysms].

    Science.gov (United States)

    Li, Baomin; Liang, Yongping; Liu, Xinfeng; Wang, Jun; Li, Sheng; Cao, Xiangyu; Ge, Aili; Feng, Huimin

    2015-08-01

    To investigate the feasibility,safety and follow-up results of multiple stents parallel placement and reconstruction technique for treating giant vertebrobasilar dissecting aneurysms. Five consecutive patients with giant fusiform vertebrobasilar dissecting aneurysms in Department of Neurology,Chinese People's Liberation Army General Hospital were retrospectively reviewed from April 2011 to October 2013. All patients were diagnosed vertebrobasilar dissecting aneurysms by MRI and digital subtraction angiography (DSA), the aneurysm size ranged 8.2-15.0 mm. All patients were treated by multiple stents parallel placement and reconstruction technique under general anesthesia. In the endovascular treatment process, 2-3 Solitaire or Neuroform self-expandable stents were parallel implanted in the maximum extension segment of the aneurysms to reconstruct the cavity of the aneurysm and solved the problem that the diameter of the intracranial stent is less than the diameter of the aneurysms. Multiple stents parallel placement can keep the stents stable in the cavity. The parallel stent can close the dissection as well as strengthen the aneurysm walls to alleviate the vessel pulsative compression of the brain stem. Furthermore, one of the parallel stents was selected for the main blood flow channel. Based on the main channel, telescope technique was used to completely covering the dissection. It can not only prevent the progress of dissection to normal regions, but also be helpful for blood flow channel reconstruction to reduce the hemodynamic disorders. All Patients received routine antiplatelet therapy before and after endovascular treatment. The operative procedures were succeeded in all patients. Five patients were implanted 18 stents (3 stents in 3 patients; 4 stents in 1 patient; 5 stents in 1 patient; parallel 3 stents in 2 patients; parallel 2 stents in 3 patients). The signs and symptoms of brain stem and posterior group of cranial nerves improved significantly. All

  10. [A minimally invasive extraction technique using Benex Extraction System in flapless immediate implant placement in anterior teeth].

    Science.gov (United States)

    Ren, Shu-Xin; Hu, Xiu-Lian; Li, Jian-Hui; Jiang, Xi; Lin, Ye

    2016-06-01

    To evaluate the feasibility and clinical outcomes of an atraumatic extraction technique using Benex Extraction System in flapless immediate implant placement in anterior teeth. Twenty-five patients with single hopeless anterior maxillary teeth were enrolled in the study. The involved teeth were extracted using Benex Extraction System and implants were immediately placed in a flapless way. Healing abutments were connected immediately. After 4-6 months of healing, screw-retained implant temporary crowns were used to reshape the peri-implant gingiva. Permanent restorations were delivered 3 months later. Extraction time was recorded and the technique feasibility was evaluated using visual analogue scale (VAS). Peri-implant marginal bone resorption was measured in X- ray films after loading for 1 year later. Pink esthetic score (PES) was checked to evaluate the gingival esthetics. Questionnaire was delivered and collected to assess patients' satisfaction on surgical experience and esthetic outcomes. SPSS 13.0 software package was used for statistical analysis. Twenty-five implants osseointegrated successfully. The marginal bone resorption was (0.21±0.23) mm and PES was 8.8±1.19 after loading for 1 year. The mean extraction time was 6.87 minutes and the VAS was 3.32. All patients were satisfied with the final esthetic outcomes and felt comfort during surgery. According to the limited data in the study, Benex extraction System is a convenient, atraumatic and predictable technique during flapless immediate implant placement in anterior teeth.

  11. Multiscale variation-aware techniques for high-performance digital microfluidic lab-on-a-chip component placement.

    Science.gov (United States)

    Liao, Chen; Hu, Shiyan

    2011-03-01

    The invention of microfluidic lab-on-a-chip alleviates the burden of traditional biochemical laboratory procedures which are often very expensive. Device miniaturization and increasing design complexity have mandated a shift in digital microfluidic lab-on-a-chip design from traditional manual design to computer-aided design (CAD) methodologies. As an important procedure in the lab-on-a-chip layout CAD, the lab-on-a-chip component placement determines the physical location and the starting time of each operation such that the overall completion time is minimized while satisfying nonoverlapping constraint, resource constraint, and scheduling constraint. In this paper, a multiscale variation-aware optimization technique based on integer linear programming is proposed for the lab-on-a-chip component placement. The simulation results demonstrate that without considering variations, our technique always satisfies the design constraints and largely outperforms the state-of-the-art approach, with up to 65.9% reduction in completion time. When considering variations, the variation-unaware design has the average yield of 2%, while our variation-aware technique always satisfies the yield constraint with only 7.7% completion time increase.

  12. Implementing the Verbal Behavior Milestones Assessment and Placement Program (VB-MAPP): Teaching Assessment Techniques.

    Science.gov (United States)

    Barnes, Clarissa S; Mellor, James R; Rehfeldt, Ruth Anne

    2014-06-01

    The Verbal Behavior Milestones Assessment and Placement Program (VB-MAPP) is an assessment tool used with individuals diagnosed with autism spectrum disorder and other language delays (Sundberg 2008). The milestones assessment section of the VB-MAPP is used to determine an individual's current skill level. The results of the milestones assessment can be used to identify instructional goals and objectives. The current study examined the effects of behavioral skills training (BST) on the administration of the milestones assessment by two educational professionals. The BST intervention resulted in immediate increases in performance for both participants.

  13. Machine learning techniques to select Be star candidates. An application in the OGLE-IV Gaia south ecliptic pole field

    Science.gov (United States)

    Pérez-Ortiz, M. F.; García-Varela, A.; Quiroz, A. J.; Sabogal, B. E.; Hernández, J.

    2017-09-01

    Context. Optical and infrared variability surveys produce a large number of high quality light curves. Statistical pattern recognition methods have provided competitive solutions for variable star classification at a relatively low computational cost. In order to perform supervised classification, a set of features is proposed and used to train an automatic classification system. Quantities related to the magnitude density of the light curves and their Fourier coefficients have been chosen as features in previous studies. However, some of these features are not robust to the presence of outliers and the calculation of Fourier coefficients is computationally expensive for large data sets. Aims: We propose and evaluate the performance of a new robust set of features using supervised classifiers in order to look for new Be star candidates in the OGLE-IV Gaia south ecliptic pole field. Methods: We calculated the proposed set of features on six types of variable stars and also on a set of Be star candidates reported in the literature. We evaluated the performance of these features using classification trees and random forests along with the K-nearest neighbours, support vector machines, and gradient boosted trees methods. We tuned the classifiers with a 10-fold cross-validation and grid search. We then validated the performance of the best classifier on a set of OGLE-IV light curves and applied this to find new Be star candidates. Results: The random forest classifier outperformed the others. By using the random forest classifier and colours criteria we found 50 Be star candidates in the direction of the Gaia south ecliptic pole field, four of which have infrared colours that are consistent with Herbig Ae/Be stars. Conclusions: Supervised methods are very useful in order to obtain preliminary samples of variable stars extracted from large databases. As usual, the stars classified as Be stars candidates must be checked for the colours and spectroscopic characteristics

  14. Techniques and Results for Determining Window Placement and Configuration for the Small Pressurized Rover (SPR)

    Science.gov (United States)

    Thompson, Shelby; Litaker, Harry; Howard, Robert

    2009-01-01

    A natural component to driving any type of vehicle, be it Earth-based or space-based, is visibility. In its simplest form visibility is a measure of the distance at which an object can be seen. With the National Aeronautics and Space Administration s (NASA) Space Shuttle and the International Space Station (ISS), there are human factors design guidelines for windows. However, for planetary exploration related vehicles, especially land-based vehicles, relatively little has been written on the importance of windows. The goal of the current study was to devise a proper methodology and to obtain preliminary human-in-the-loop data on window placement and location for the small pressurized rover (SPR). Nine participants evaluated multiple areas along the vehicle s front "nose", while actively maneuvering through several lunar driving simulations. Subjective data was collected on seven different aspects measuring areas of necessity, frequency of views, and placement/configuration of windows using questionnaires and composite drawings. Results indicated a desire for a large horizontal field-of-view window spanning the front of the vehicle for most driving situations with slightly reduced window areas for the lower front, lower corners, and side views.

  15. Inferior Alveolar Nerve Lateralization and Transposition for Dental Implant Placement. Part I: a Systematic Review of Surgical Techniques

    Directory of Open Access Journals (Sweden)

    Boris Abayev

    2015-03-01

    Full Text Available Objectives: The purpose of this first part of a two-part series was to review the literature concerning the indications, contraindications, advantages, disadvantages and surgical techniques of the lateralization and transposition of the inferior alveolar nerve, followed by the placement of an implant in an edentulous atrophic posterior mandible. Material and Methods: A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed and PMC database, academic sites and books. The articles were searched from January 1997 to July 2014 and comprised English-language articles that included adult patients between 18 and 80 years old with minimal residual bone above the mandibular canal who had undergone inferior alveolar nerve (IAN repositioning with a minimum 6 months of follow-up. Results: A total of 16 studies were included in this review. Nine were related to IAN transposition, 4 to IAN lateralization and 3 to both transposition and lateralization. Implant treatment results and complications were presented. Conclusions: Inferior alveolar nerve lateralization and transposition in combination with the installation of dental implants is sometimes the only possible procedure to help patients to obtain a fixed prosthesis, in edentulous atrophic posterior mandibles. With careful pre-operative surgical and prosthetic planning, imaging, and extremely precise surgical technique, this procedure can be successfully used for implant placement in edentulous posterior mandibular segments.

  16. Mechanical Elongation of the Small Intestine: Evaluation of Techniques for Optimal Screw Placement in a Rodent Model

    Directory of Open Access Journals (Sweden)

    P. A. Hausbrandt

    2013-01-01

    Full Text Available Introduction. The aim of this study was to evaluate techniques and establish an optimal method for mechanical elongation of small intestine (MESI using screws in a rodent model in order to develop a potential therapy for short bowel syndrome (SBS. Material and Methods. Adult female Sprague Dawley rats (n=24 with body weight from 250 to 300 g (Σ=283 were evaluated using 5 different groups in which the basic denominator for the technique involved the fixation of a blind loop of the intestine on the abdominal wall with the placement of a screw in the lumen secured to the abdominal wall. Results. In all groups with accessible screws, the rodents removed the implants despite the use of washers or suits to prevent removal. Subcutaneous placement of the screw combined with antibiotic treatment and dietary modifications was finally successful. In two animals autologous transplantation of the lengthened intestinal segment was successful. Discussion. While the rodent model may provide useful basic information on mechanical intestinal lengthening, further investigations should be performed in larger animals to make use of the translational nature of MESI in human SBS treatment.

  17. Socket Shield Technique for immediate implant placement - clinical, radiographic and volumetric data after 5 years.

    Science.gov (United States)

    Bäumer, Daniel; Zuhr, Otto; Rebele, Stephan; Hürzeler, Markus

    2017-11-01

    Implant placement immediately after tooth extraction is often accompanied by resorption of surrounding tissues. A clinical technique was developed where the buccal portion of the root is retained to preserve the periodontal ligament and bundle bone. This technique is based on animal studies showing the potential to preserve the facial tissues utilizing this approach. The purpose of this study was to gain more insight regarding the safety of the technique with regard to biological and implant-related long-term complications and to observe the clinical appearance of the peri-implant tissues. Another objective was to evaluate volumetric changes of the affected facial contours in long-term and the esthetic outcomes. This study is a retrospective case series of 10 consecutive patients with implant replacement between the maxillary first premolars. Impressions were made prior to extraction (t1) and 5 years post-implant placement (t2). 3D-surface scans of the casts were digitally superimposed for quantitative evaluation of alterations of the facial peri-implant tissue contours and soft tissue recessions. Additionally, clinical data were collected (PPD, BOP, peri-apical radiographs and photographs). All implants healed without adverse events. Peri-implant probing revealed healthy conditions. The comparison of radiographic images showed physiologic bone remodeling at the implant shoulders. Mean tissue loss on the facial side in oro-facial direction was -0.21 ± 0.18 mm. Average recession at implants was -0.33 ± 0.23 mm and at neighboring teeth -0.38 ± 0.27 mm. Mean loss of the marginal bone level at the implant shoulder amounted to 0.33 ± 0.43 mm at the mesial and 0.17 ± 0.36 mm at the distal aspect of the implants. A mean pink esthetic score of 12 was recorded. Volumetric analysis showed a low degree of contour changes from extraction and implant placement to the follow-ups. Mucosal recession at the implant restoration was comparable to that of the

  18. The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

    International Nuclear Information System (INIS)

    Chang, Il Soo; Park, Sang Woo; Hwang, Dae Yong; Seong, Moo Kyung; Joh, Hee Kyung; Yoon, So Young; Cho, Yo Han; Choe, Won Hyeok

    2011-01-01

    We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4: mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon

  19. Use of the Toric Surgical Marker to Aid in Intraoperative Plaque Placement for the USC Eye Physics Plaques to Treat Uveal Melanoma: A New Surgical Technique.

    Science.gov (United States)

    Berry, Jesse L; Kim, Jonathan W; Jennelle, Richard; Astrahan, Melvin

    2015-09-01

    To describe a new surgical technique for intraoperative placement of Eye Physics (EP) plaques for uveal melanoma using a toric marker. A toric marker is designed for cataract surgery to align the axis of astigmatism; its use was modified in this protocol to mark the axis of suture coordinates as calculated by Plaque Simulator (PS) software. The toric marker can be used to localize suture coordinates, in degrees, during intraoperative plaque placement. Linear marking using the toric marker decreases potential inaccuracies associated with the surgeon estimating 'clock-hours' by dot placement. Use of the toric marker aided surgical placement of EP plaques. The EP planning protocol is now designed to display the suture coordinates either by clock-hours or degrees, per surgeon preference. Future research is necessary to determine whether routine use of the toric marker improves operative efficiency. [Ophthalmic Surg Lasers Imaging Retina. 2015;46:866-870.]. Copyright 2015, SLACK Incorporated.

  20. Technique to assess the alveolar bone width for immediate implant placement in fresh extraction sockets

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar Chandraker

    2013-01-01

    Conclusion: This technique will help the surgeon understand the thickness of labial plate especially the apical region without reflecting the flap, also aid in selection of proper dimension of dental implant, and if bone graft is needed.

  1. A clever technique for placement of a urinary catheter over a wire

    Directory of Open Access Journals (Sweden)

    Joel E Abbott

    2015-01-01

    Conclusion: Placing urinary catheters over a wire is standard practice for urologists, however, use of this technique gives the freedom of performing wire-guided catheterization in more situations than a council-tip allows. This technique facilitates successful transurethral catheterization over wire in the setting of DUC for all catheter types and styles aiding in urologic management of patients at a cost benefit to the health care system.

  2. Efficacy of needle-placement technique in radiofrequency ablation for treatment of lumbar facet arthropathy.

    Science.gov (United States)

    Loh, Jeffrey T; Nicol, Andrea L; Elashoff, David; Ferrante, F Michael

    2015-01-01

    Many studies have assessed the efficacy of radiofrequency ablation to denervate the facet joint as an interventional means of treating axial low-back pain. In these studies, varying procedural techniques were utilized to ablate the nerves that innervate the facet joints. To date, no comparison studies have been performed to suggest superiority of one technique or even compare the prevalence of side effects and complications. A retrospective chart review was performed on patients who underwent a lumbar facet denervation procedure. Each patient's chart was analyzed for treatment technique (early versus advanced Australian), preprocedural visual numeric scale (VNS) score, postprocedural VNS score, duration of pain relief, and complications. Pre- and postprocedural VNS scores and change in VNS score between the two groups showed no significant differences. Patient-reported benefit and duration of relief was greater in the advanced Australian technique group (P=0.012 and 0.022, respectively). The advanced Australian technique group demonstrated a significantly greater median duration of relief (4 months versus 1.5 months, P=0.022). Male sex and no pain-medication use at baseline were associated with decreased postablation VNS scores, while increasing age and higher preablation VNS scores were associated with increased postablation VNS scores. Despite increasing age being associated with increased postablation VNS scores, age and the advanced Australian technique were found to confer greater patient self-reported treatment benefit. The advanced Australian technique provides a significant benefit over the early Australian technique for the treatment of lumbar facet pain, both in magnitude and duration of pain relief.

  3. Efficacy of needle-placement technique in radiofrequency ablation for treatment of lumbar facet arthropathy

    Science.gov (United States)

    Loh, Jeffrey T; Nicol, Andrea L; Elashoff, David; Ferrante, F Michael

    2015-01-01

    Background Many studies have assessed the efficacy of radiofrequency ablation to denervate the facet joint as an interventional means of treating axial low-back pain. In these studies, varying procedural techniques were utilized to ablate the nerves that innervate the facet joints. To date, no comparison studies have been performed to suggest superiority of one technique or even compare the prevalence of side effects and complications. Materials and methods A retrospective chart review was performed on patients who underwent a lumbar facet denervation procedure. Each patient’s chart was analyzed for treatment technique (early versus advanced Australian), preprocedural visual numeric scale (VNS) score, postprocedural VNS score, duration of pain relief, and complications. Results Pre- and postprocedural VNS scores and change in VNS score between the two groups showed no significant differences. Patient-reported benefit and duration of relief was greater in the advanced Australian technique group (P=0.012 and 0.022, respectively). The advanced Australian technique group demonstrated a significantly greater median duration of relief (4 months versus 1.5 months, P=0.022). Male sex and no pain-medication use at baseline were associated with decreased postablation VNS scores, while increasing age and higher preablation VNS scores were associated with increased postablation VNS scores. Despite increasing age being associated with increased postablation VNS scores, age and the advanced Australian technique were found to confer greater patient self-reported treatment benefit. Conclusion The advanced Australian technique provides a significant benefit over the early Australian technique for the treatment of lumbar facet pain, both in magnitude and duration of pain relief. PMID:26504407

  4. Efficacy of needle-placement technique in radiofrequency ablation for treatment of lumbar facet arthropathy

    Directory of Open Access Journals (Sweden)

    Loh JT

    2015-10-01

    Full Text Available Jeffrey T Loh,1 Andrea L Nicol,1 David Elashoff,2 F Michael Ferrante,1 1Department of Anesthesiology, David Geffen School of Medicine, 2Department of Biomathematics, University of California Los Angeles, Los Angeles, CA, USA Background: Many studies have assessed the efficacy of radiofrequency ablation to denervate the facet joint as an interventional means of treating axial low-back pain. In these studies, varying procedural techniques were utilized to ablate the nerves that innervate the facet joints. To date, no comparison studies have been performed to suggest superiority of one technique or even compare the prevalence of side effects and complications. Materials and methods: A retrospective chart review was performed on patients who underwent a lumbar facet denervation procedure. Each patient's chart was analyzed for treatment technique (early versus advanced Australian, preprocedural visual numeric scale (VNS score, postprocedural VNS score, duration of pain relief, and complications. Results: Pre- and postprocedural VNS scores and change in VNS score between the two groups showed no significant differences. Patient-reported benefit and duration of relief was greater in the advanced Australian technique group (P=0.012 and 0.022, respectively. The advanced Australian technique group demonstrated a significantly greater median duration of relief (4 months versus 1.5 months, P=0.022. Male sex and no pain-medication use at baseline were associated with decreased postablation VNS scores, while increasing age and higher preablation VNS scores were associated with increased postablation VNS scores. Despite increasing age being associated with increased postablation VNS scores, age and the advanced Australian technique were found to confer greater patient self-reported treatment benefit. Conclusion: The advanced Australian technique provides a significant benefit over the early Australian technique for the treatment of lumbar facet pain, both in

  5. Layout-Driven Post-Placement Techniques for Temperature Reduction and Thermal Gradient Minimization

    DEFF Research Database (Denmark)

    Liu, Wei; Calimera, Andrea; Macii, Alberto

    2013-01-01

    With the continuing scaling of CMOS technology, on-chip temperature and thermal-induced variations have become a major design concern. To effectively limit the high temperature in a chip equipped with a cost-effective cooling system, thermal specific approaches, besides low power techniques, are ...

  6. Impact of the Hall technique for preformed metal crown placement on undergraduate paediatric dentistry experience.

    Science.gov (United States)

    Gilchrist, F; Morgan, A G; Farman, M; Rodd, H D

    2013-02-01

    The Hall technique, a novel method of placing preformed metal crowns (PMCs) without local anaesthesia or tooth preparation, was introduced to our undergraduate dental curriculum in 2009. This study aimed to describe student experience of, and attitudes towards, PMCs before and after exposure to this new technique. Clinical data were extracted from student logbooks to determine the number of PMCs placed for cohorts graduating in 2005 (n = 55), 2009 (n = 61) and 2010 (n = 75). Five focus groups were also conducted with 29 final-year dental students. Students graduating in 2005, 2009 and 2010 had placed a mean (range) of 0.03 (0-1), 0.63 (0-5) and 1.15 (0-9) PMCs, respectively. The proportion of students who had placed a PMC increased significantly from only 1.9% in 2005 to 75% in 2010 (P < 0.05, ANOVA). Students reported some positive experiences of the Hall technique. However, concern over perceived lack of future clinical support, an anticipated increase in time and financial pressures, and the ease of use of glass-ionomer cement as an alternative were described as potential barriers to PMC use. Findings suggest that the introduction of the Hall technique has had a marked impact on the use of PMCs as a treatment modality for carious primary teeth. © 2012 John Wiley & Sons A/S.

  7. A Novel Technique of Fabricating a Modified Removable Provisional Prosthesis over an Autologous Bone Grafted Maxillary Anterior Edentulous Segment Prior to Implant Placement

    OpenAIRE

    Andonissamy, Leoney; Vidhya, N. Sri

    2017-01-01

    Implant dentistry has provided a lot of surgical as well as prosthetic techniques for improving the success of the implants. The surgical technique commonly followed now prior to implant placement is bone grafting procedure. One of the commonest techniques is the use of autologous block graft harvested from mandibular chin region. However, interference in healing as well as excessive bone resorption due to the use of removable provisional prosthesis over the bone grafted region has been commo...

  8. Surgical technique for permanent intracoelomic radiotransmitter placement in Anegada iguanas (Cyclura pinguis).

    Science.gov (United States)

    Ferrell, Shannon T; Marlar, Annajane B; Alberts, Allison C; Young, Lee A; Bradley, Kelly; Hurlbut, Sandra L; Lung, Nancy P

    2005-12-01

    Twenty-four juvenile to subadult Anegada iguanas (Cyclura pinguis), captive-reared in a propagation facility, were designated by a coordinated recovery program for release in the summer of 2003. To facilitate postrelease monitoring, a radiotransmitter device was placed within the coelomic cavity of each animal under general anesthesia before release. The equipment sterilization technique and the method of attachment of the transmitters to the coelomic body wall resulted in functional transmitters and acceptably low rates of mortality associated with the procedure.

  9. How does sacral modulation work best? Placement and programming techniques to maximize efficacy.

    Science.gov (United States)

    Amend, Bastian; Khalil, Mahmoud; Kessler, Thomas M; Sievert, Karl-Dietrich

    2011-10-01

    Since receiving approval from the US Food and Drug Administration in 1997, sacral neuromodulation (SNM) has become the recommended treatment of urinary urge incontinence, urgency-frequency, nonobstructive urinary retention, and fecal incontinence. The manufacturer has introduced different technical modifications while surgeons and researchers have adapted and published various innovations and alterations of the technique. This review summarizes the current knowledge and recommendations of SNM preoperative decision making, the implantation technique, and available programming parameters and algorithms based on MEDLINE research, manufacturer instructions, and the approach of an experienced neurourological team. The primary steps and technical aspects to optimize SNM efficacy were the introduction of the tined-lead electrode and the development of the InterStim II impulse generator (both developed by Medtronic, Inc., Minneapolis, MN). The initiation of the staged implantation technique for sequential evaluation and implantation with the definitive quadripolar electrode completes the treatment algorithm so that an increased responder rate of SNM for all indications can be achieved. © Springer Science+Business Media, LLC 2011

  10. Story Themes from the Family Distance Doll Placement Technique: A Method for Assessing Patterns of Closeness and Distance in Families of Disturbed and Normal Boys.

    Science.gov (United States)

    Gerber, Gwendolyn L.

    The diagnosis and evaluation of families applying for family therapy is necessary to identify problems in their relationships that can be effectively integrated into treatment. In the Family Distance Doll Placement technique, a diagnostic tool for assessing patterns of closeness and distance within the family, parents are asked to make up stories…

  11. Magnet pole tips

    Science.gov (United States)

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  12. Comparative radiographic and resonance frequency analyses of the peri-implant tissue after dental implants placement using flap and flapless techniques: An experimental study on domestic pigs

    Directory of Open Access Journals (Sweden)

    Vlahović Zoran

    2013-01-01

    Full Text Available Background/Aim. Flapless implant surgery has become very important issue during recent years, mostly thanks to computerization of dentistry and software planning of dental implants placements. The aim of this study was to compare flap and flapless surgical techniques for implant placement through radiographic and radiofrequency analyses. Methods. The experiment was made in five domestic pigs. Nine weeks following domestic pigs teeth extraction, implants were placed, on the right side using surgical technique flap, and flapless on the left side. Digital dental Xrays were applied to determine primary dental implant stability quality (ISQ. At certain intervals, not later than three months, the experimental animals were sacrificed, and just before it, control X-rays were applied to measure dental implants stability. Results. Radiographic analysis showed that peri-implant bone resorption in the first 4 weeks following placement implants with flap and flapless surgical techniques was negligible. After the 3 months, mean value of peri-implant bone resorption of the implants placed using flap technique was 1.86 mm, and of those placed using flapless technique was 1.13 mm. In relation to the primary dental implant stability in the first and second week there was an expected decrease in ISQ values, but it was less expressed in the dental implants placed using the flapless technique. In the third week the ISQ values were increased in the dental implants placed by using both techniques, but the increase in flapless implant placement was higher (7.4 ISQ than in flap implant placement (1.5 ISQ. The upward trend continued in a 4- week period, and after 3 months the dental implant stability values in the implants placed using flap technique were higher than the primary stability for 7.1 ISQ, and in the implants placed using flapless technique were higher comparing to the primary stability for 10.1 ISQ units. Conclusion. Based on the results of radiographic and

  13. A contemporary approach for treatment planning of horizontally resorbed alveolar ridge: Ridge split technique with simultaneous implant placement using platelet rich fibrin membrane application in mandibular anterior region

    Directory of Open Access Journals (Sweden)

    Prathahini S Parthiban

    2017-01-01

    Full Text Available Treatment of edentulous sites with horizontal atrophy represents a clinical situation in which the positioning of endosseous implants might be complex or sometimes impossible without a staged regenerative approach. This case report presents management of horizontally deficient mandibular anterior ridge with a contemporary approach to treatment planning and application of platelet-rich fibrin membrane for ridge split technique and simultaneous implant placement. Implants in anterior mandibular area are considered to be most predictable, stable, with high success rate and patients' satisfaction with implant esthetics. In contrast to traditional ridge augmentation techniques, ridge splitting allows for immediate implant placement following surgery and eradicates the possible morbidity from a second surgical site.

  14. The use of a position sensitive detector or of a multidetector for the measurement of pole figures by neutron time-of-flight technique

    International Nuclear Information System (INIS)

    Walther, K.

    1990-01-01

    The neutron flux of even high flux reactors is weak in comparison with the quantum flux of X-ray tubes and therefore in order to decrease the expense on measuring time more and more neutron diffractometers are equipped with position sensitive detectors or multidetectors. In this paper the peculiarities of the use of such detecting devices are discussed for the measurement of pole figures. A special arrangement of a multidetector is proposed which will allow one to scan the whole pole figure by rotating the sample about only one axis and considerably will save measuring time. 4 refs.; 5 figs

  15. Second-harmonic imaging of poled silica waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Pedersen, Kjeld; Bozhevolnyi, Sergey I.

    2000-01-01

    Electric-field poled silica-based waveguides are characterized by measurements of second-harmonic generation (SHG) and of the linear electro-optic effect (LEO). A SHG scanning technique allowing for high-resolution imaging of poled devices is demonstrated. Scans along the direction of the poling...

  16. Special considerations for placement of an inflatable penile prosthesis for the patient with Peyronie’s disease: techniques and patient preference

    Science.gov (United States)

    Lyons, Matthew D; Carson, Culley C; Coward, Robert M

    2015-01-01

    Placement of an inflatable penile prosthesis (IPP) is the mainstay of surgical treatment for patients with Peyronie’s disease (PD) and concomitant medication-refractory erectile dysfunction. Special considerations and adjunctive surgical techniques during the IPP procedure are often required for patients with PD to improve residual penile curvature, as well as postoperative penile length. The surgical outcomes and various adjunctive techniques are not significantly different from one another, and selection of the appropriate technique must be tailored to patient-specific factors including the extent of the deformity, the degree of penile shortening, and preoperative patient expectations. The aims of this review were to assess the current literature on published outcomes and surgical techniques involving IPP placement in the treatment of PD. Patient satisfaction and preferences are reported, along with the description and patient selection for surgical techniques that include manual penile modeling, management of refractory curvature with concurrent plication, and correction of severe residual curvature and penile shortening with tunica release and plaque incision and grafting. A thorough description of the available techniques and their associated outcomes may help guide surgeons to the most appropriate choice for their patients. PMID:26251633

  17. Validation of the unassisted, gum-elastic bougie-guided, laryngeal mask airway-ProSeal™ placement technique in anaesthetized patients

    Directory of Open Access Journals (Sweden)

    Aaron M Joffe

    2012-01-01

    Full Text Available Aims: The laryngeal mask airway-ProSeal™ can be inserted digitally, by introducer tool, or by railroading it over a bougie placed first in the patient′s oesophagus, which is highly successful, but as originally described, requires an assistant. An unassisted bougie-guided placement technique has also been described, but no data on its effectiveness have been reported. Methods: We reviewed data collected during a randomized, controlled trial comparing the air-Q® Intubating Laryngeal Airway and LMA-Proseal™, in which all LMA-Proseal™ devices were inserted using the unassisted (one-operator, bougie-guided placement technique. Results: Forty-eight devices were placed. All devices were placed successfully. Successful placement was achieved in 47 (98% patients on first attempt and in one (2% patient on the third attempt. Mean (SD time required for insertion establishing ventilation was 28 (11 s. Mean (SD airway seal pressure was 30 (6 cmH 2 O. Gross blood was found on four (8% devices upon removal, but no oropharyngeal injuries were noted on oral exam in the recovery unit prior to discharge. The most common complaints in recovery and 24 h post-operatively were sore throat [discharge: mild = 18/48 (38%; 24 h: mild = 9/38 (19%, moderate = 1/38 (3%] and pain on swallowing [discharge: mild = 7/48 (15%; 24 h: mild = 2/38 (6%]. Conclusions: Our data confirm that in experienced hands, bougie-guided placement of the LMA-Proseal™ without the aid of an assistant can be accomplished quickly and successfully without affecting the expected clinical performance of the device.

  18. Real-time thermographic analysis of low-density bone during implant placement: a randomized parallel-group clinical study comparing lateral condensation with bone drilling surgical technique.

    Science.gov (United States)

    Marković, Aleksa; Mišić, Tijana; Mančić, Dragan; Jovanović, Igor; Šćepanović, Miodrag; Jezdić, Zoran

    2014-08-01

    To compare the effect of two surgical techniques, lateral condensation and bone drilling, on changes in temperature of the adjacent low-density bone during implant placement into posterior maxilla and to investigate the influence of the host factors - age, gender, region of implantation, bone density, and thickness of the cortical bone at the recipient sites. Local bone temperature was measured thermographically during implant placement into posterior maxilla following lateral bone condensing (test group) or bone drilling (controls). The main study outcomes were baseline bone temperature prior to implantation and maximum bone temperature recorded during implantation. Early implant success was evaluated after 6 months of healing. A total of 40 implants were randomly allocated to test and control groups and placed into maxillary premolar and/or molar region of 18 participants of both genders and average age of 51.74 years. All recorded bone temperatures were below the threshold for thermal necrosis. Although both groups showed significant increase in bone temperature during implant placement procedure (P ≤ 0.0005), it was significantly higher for bone condensing compared with drilling (P ≤ 0.0005; 3.79 ± 1.54°C; 1.91 ± 0.70°C respectively). No host factor was singled out as a significant predictor of bone temperature changes, although trend of higher increase was observed in young patients, regardless of gender, during implant placement procedure into maxillary first premolar region with bone density type 3 and cortical layer thicker than 1 mm. Early implant success rate after 6 months follow-up was 100%. Although both surgical techniques, bone condensing and bone drilling, can be considered safe regarding their thermal effect on the bone of posterior maxilla, bone drilling is associated with fewer local bone heating during implantation. Host factors do not affect the bone thermal changes significantly. © 2013 John Wiley & Sons A/S. Published by John Wiley

  19. Can a Drill Guide Improve the Coracoid Graft Placement During the Latarjet Procedure? A Prospective Comparative Study With the Freehand Technique.

    Science.gov (United States)

    Barth, Johannes; Boutsiadis, Achilleas; Neyton, Lionel; Lafosse, Laurent; Walch, Gilles

    2017-10-01

    One of the factors that can affect the success of the Latarjet procedure is accurate coracoid graft (CG) placement. The use of a guide can improve placement of the CG and screw positioning in the sagittal and axial planes as compared with the classic open ("freehand") technique. Cohort study; Level of evidence, 2. A total of 49 patients who underwent a Latarjet procedure for the treatment of recurrent anterior shoulder instability were prospectively included; the procedure was performed with the freehand technique in 22 patients (group 1) and with use of a parallel drill guide during screw placement in 27 patients (group 2). All patients underwent a postoperative computed tomography scan with the same established protocol. The scans were used to evaluate and compare the position of the CG in the sagittal and axial planes, the direction of the screws (α angle), and overall contact of the graft with the anterior surface of the glenoid after the 2 surgical techniques. The CG was placed >60% below the native glenoid equator in 23 patients (85.2%) in group 2, compared with 14 patients (63.6%) in group 1 ( P = .004). In the axial plane, the position of the CG in group 2 patients was more accurate (85.2% and 88.9% flush) at the inferior and middle quartiles of the glenoid surface ( P = .012 and .009), respectively. Moreover, with the freehand technique (group 1), the graft was in a more lateral position in the inferior and middle quartiles ( P = .012 and .009, respectively). No differences were found between groups 1 and 2 regarding the mean α angle of the superior (9° ± 4.14° vs 11° ± 6.3°, P = .232) and inferior (9.5° ± 6° vs 10° ± 7.5°, P = .629) screws. However, the mean contact angle (angle between the posterior coracoid and the anterior glenoid surface) with the freehand technique (3.8° ± 6.8°) was better than that of the guide (8.55° ± 8°) ( P = .05). Compared with the classic freehand operative technique, the parallel drill guide can ensure

  20. A comparative study of two techniques (electrocardiogram- and landmark-guided for correct depth of the central venous catheter placement in paediatric patients undergoing elective cardiovascular surgery

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar Barnwal

    2016-01-01

    Full Text Available Background and Aims: The complications of central venous catheterisation can be minimized by ensuring catheter tip placement just above the superior vena cava-right atrium junction. We aimed to compare two methods, using an electrocardiogram (ECG or landmark as guides, for assessing correct depth of central venous catheter (CVC placement. Methods: In a prospective randomised study of sixty patients of <12 years of age, thirty patients each were allotted randomly to two groups (ECG and landmark. After induction, central venous catheterisation was performed by either of the two techniques and position of CVC tip was compared in post-operative chest X-ray with respect to carina. Unpaired t-test was used for quantitative data and Chi-square test was used for qualitative data. Results: In ECG group, positions of CVC tip were above carina in 12, at carina in 9 and below carina in 9 patients. In landmark group, the positions of CVC tips were above carina in 10, at carina in 4 and below carina in 16 patients. Mean distance of CVC tip in ECG group was 0.34 ± 0.23 cm and 0.66 ± 0.35 cm in landmark group (P = 0.0001. Complications occurred in one patient in ECG group and in nine patients in landmark group (P = 0.0056. Conclusion: Overall, landmark-guided technique was comparable with ECG technique. ECG-guided technique was more precise for CVC tip placement closer to carina. The incidence of complications was more in the landmark group.

  1. A Novel Technique of Fabricating a Modified Removable Provisional Prosthesis over an Autologous Bone Grafted Maxillary Anterior Edentulous Segment Prior to Implant Placement.

    Science.gov (United States)

    Andonissamy, Leoney; Vidhya, N Sri

    2017-09-01

    Implant dentistry has provided a lot of surgical as well as prosthetic techniques for improving the success of the implants. The surgical technique commonly followed now prior to implant placement is bone grafting procedure. One of the commonest techniques is the use of autologous block graft harvested from mandibular chin region. However, interference in healing as well as excessive bone resorption due to the use of removable provisional prosthesis over the bone grafted region has been commonly observed/reported. Hence now-a-days, fixed provisional prosthesis is preferred over removable provisional prosthesis for the added advantages of superior aesthetics and patient acceptance. This article highlights a new technique of fabricating removable provisional prosthesis, which is superior in aesthetics and strength, consumes less chair time and exerts zero pressure onto the grafted site.

  2. Fluoroscopy-guided placement of nasoenteral tubes in children using intermittent digital pulse fluoroscopy and last image save/grab technique.

    Science.gov (United States)

    Rao, A G; Simmons, C E; Collins, H; Tipnis, S V; Hill, J G; Ritenour, E R

    2016-09-01

    To document the radiation exposure metrics, including fluoroscopic radiation time and radiation dose-area product, in children fluoroscopy time, and radiation dose-area product were collected retrospectively in all paediatric patients who underwent fluoroscopically guided nasoenteral tube placement during a 5-year period. Three paediatric radiology faculty members, a radiologist assistant, and trainee residents during their paediatric radiology rotation performed the procedures on two different digital fluoroscopic machines using radiation-minimising techniques. Median values of the fluoroscopy time and radiation dose-area product were calculated and compared to values reported in the literature using the Wilcoxon procedure. There were 41 male and 33 female patients with a median age of 4 years and 6 months. Median fluoroscopy time used for placing a nasoenteral tube was 1.25 minutes with a median radiation exposure dose-area product of 0.245 Gy·cm(2). All patients had successful placement of nasoenteral tube without immediate procedure-related complications. Fluoroscopy-guided nasoenteral feeding tube placement can be performed successfully with minimal radiation exposure without compromising procedural success. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. Usefulness and radiological evaluation of accuracy of innovative "Smart" hand technique for pedicle screw placement: an anatomical study.

    Science.gov (United States)

    Comert, Ayhan; Dogan, İhsan; Çaglar, Y Sukru

    2017-11-01

    The aim of this study is to use a smartphone application during pedicle screw placement navigation and examine the accuracy of this application on anatomical dry vertebrae model. 76 dry vertebrae were used for this study and pedicle entry points, projections of pedicle screw trajectory lines in lateral and superior aspect of vertebral body were identified and drawn for each vertebra bilaterally. In each position, all angulations were measured directly before the procedure manually. 152 pedicle screws were inserted as a simulation of screw placement with the guidance of angle-meter smart app. Accuracy of the method was tested according to the occurrence of bone penetration and angular deviation of the inserted screws was evaluated in computed tomography images. Mean deviation of pedicle screws of 76 pedicle screws in right side in horizontal plane was measured 2.30°±1.78°; in sagittal plane 2.17°±1.57° and in left side in horizontal plane 3.01°±1.83°; in sagittal plane 2.38°±1.68°. No bone penetration was occurred during 152 pedicle screw placements. According to the t-test results, there were significant differences between two groups in craniocaudal direction of the right side pedicle screws and in craniocaudal direction of left side pedicle screws. The free smartphone application presented here as angle-meter can be interpreted as a safe digital device for spinal instrumentation procedures. As a prototype of future pedicle screw fixation systems, it should be improved in terms of its feasibility and compatibility with screw probes. This may lead to apply mobile digital angle meter in spinal procedure.

  4. Geometric Modelling of Octagonal Lamp Poles

    Science.gov (United States)

    Chan, T. O.; Lichti, D. D.

    2014-06-01

    Lamp poles are one of the most abundant highway and community components in modern cities. Their supporting parts are primarily tapered octagonal cones specifically designed for wind resistance. The geometry and the positions of the lamp poles are important information for various applications. For example, they are important to monitoring deformation of aged lamp poles, maintaining an efficient highway GIS system, and also facilitating possible feature-based calibration of mobile LiDAR systems. In this paper, we present a novel geometric model for octagonal lamp poles. The model consists of seven parameters in which a rotation about the z-axis is included, and points are constrained by the trigonometric property of 2D octagons after applying the rotations. For the geometric fitting of the lamp pole point cloud captured by a terrestrial LiDAR, accurate initial parameter values are essential. They can be estimated by first fitting the points to a circular cone model and this is followed by some basic point cloud processing techniques. The model was verified by fitting both simulated and real data. The real data includes several lamp pole point clouds captured by: (1) Faro Focus 3D and (2) Velodyne HDL-32E. The fitting results using the proposed model are promising, and up to 2.9 mm improvement in fitting accuracy was realized for the real lamp pole point clouds compared to using the conventional circular cone model. The overall result suggests that the proposed model is appropriate and rigorous.

  5. Sub-Coronal Inflatable Penile Prosthesis Placement With Modified No-Touch Technique: A Step-by-Step Approach With Outcomes.

    Science.gov (United States)

    Weinberg, Aaron C; Pagano, Matthew J; Deibert, Christopher M; Valenzuela, Robert J

    2016-02-01

    The surgical treatment of disorders of male sexual function requires specific exposure to correct the underlying problem safely and efficiently. Currently, sub-coronal exposure is used for treatment of phimosis, Peyronie's disease plaque (PDP), and semirigid penile prosthesis insertion. Infra-pubic and scrotal incisions are used for inflatable penile prosthesis (IPP) placement. However, men who present with several disorders might require multiple procedures and surgical incisions. To report a prospective review of our surgical experience and outcomes with a single sub-coronal incision for IPP placement with a modified no-touch technique. This approach allows for access to the entire corporal body for multiple reconstructive procedures. Two hundred men had IPPs placed through a sub-coronal incision using our modified no-touch technique. The penis was degloved to the level of the penoscrotal junction and the dartos muscle was everted and secured to the drapes. This allowed exclusion of the scrotal and penile skin from the operative field. After artificial erection, the patient's corpora were inspected for PDP and other abnormalities. Penoscrotal IPP models were placed in all cases with insertion proximal to the penoscrotal junction. After placement of the IPP, the abnormalities were repaired. Feasibility of the procedure, operative times, complication rate, utilization of accessory, reconstructive procedures, and post-operative penile length. Of the 200 men who had IPP placement, 92 had PDP that was treated, 106 (53%) consented to circumcision, 24 (12%) had their reservoir placed ectopically, and 31 (16%) had a prosthesis exchanged through the sub-coronal technique. Mean operative time was 73 minutes (39-161 minutes). Specialists in the surgical treatment of disorders of male sexual function can perform multiple procedures safely and easily through a modified no-touch single sub-coronal incision. This approach allows access to the entire corporal body, providing

  6. Computer-guided flapless transmucosal implant placement in the mandible: a new combination of two innovative techniques.

    Science.gov (United States)

    Wittwer, Gert; Adeyemo, Wasiu Lanre; Schicho, Kurt; Gigovic, Natasha; Turhani, Dritan; Enislidis, Georg

    2006-06-01

    To assess whether computer-guided flapless transmucosal implant bed preparation without mucosal punching allows placement of dental implants in edentulous mandibles. Twenty patients with fully edentulous mandibles (11 male; 9 female) were included in the study. Each patient was scheduled to receive 4 screw-shaped Ankylos (Dentsply Friadent, Mannheim, Germany) implants in the interforaminal region. The StealthStation Treon navigation system (Medtronic, Minnesota, MN) was used for computer-guided drilling. Using conventional implant drills the mucosa was penetrated without flap elevation or mucosal punching. The study protocol did not allow direct visualization of the bone surface during surgery. For 78 implants (97.5%) the preoperative plan could be transfered to the patient by intraoperative navigation with a mean deviation of 0.9 mm (Implant tip 0.8 +/- 0.6 mm; coronal implant end 1.1 +/- 0.7 mm) as measured by comparing pre- and postoperative computerized tomography images. Two implants (2.5 %) were not primarily stable and failed to osseointegrate. Computer-guided transmucosal interforaminal implant placement without mucosal punching is a precise and predictable procedure. It is, however, not yet suitable for all bone morphologies. Future developments may include miniaturization of hardware and simplification of the drilling procedure.

  7. Lower pole stones

    DEFF Research Database (Denmark)

    Sanguedolce, Francesco; Breda, Alberto; Millan, Felix

    2013-01-01

    PURPOSE: To assess efficacy and safety of prone- and supine percutaneous nephrolithotomy (PCNL) for the treatment of lower pole kidney stones. METHODS: Data from patients affected by lower pole kidney stones and treated with PCNL between December 2005 and August 2010 were collected retrospectively...... by seven referral centres. Variables analysed included patient demographics, clinical and surgical characteristics, stone-free rates (SFR) and complications. Statistical analysis was conducted to compare the differences for SFRs and complication rates between prone- and supine PCNL. RESULTS: One hundred...... seventeen patients underwent PCNL (mean stone size: 19.5 mm) for stones harboured only in the lower renal pole (single stone: 53.6 %; multiple stones: 46.4 %). A higher proportion of patients with ASA score ≥ 3 and harbouring multiple lower pole stones were treated with supine PCNL (5.8 vs. 23.1 %; p = 0...

  8. Automated Fiber Placement of Advanced Materials (Preprint)

    National Research Council Canada - National Science Library

    Benson, Vernon M; Arnold, Jonahira

    2006-01-01

    .... ATK has been working with the Air Force Research Laboratory to foster improvements in the BMI materials and in the fiber placement processing techniques to achieve rates comparable to Epoxy placement rates...

  9. Evaluation of coronal microleakage of mineral trioxide aggregate plug-in teeth with short roots prepared for post placement using bacterial penetration technique.

    Science.gov (United States)

    Khademi, A A; Shekarchizade, N

    2016-01-01

    Two of the problems of the placement of posts in teeth with short roots are to determine the minimum length of the canal obturation material at the apical third of the root canal and removal of all the canal obturation material from the root canal during post space preparation. The aim of the present study was to compare the coronal microleakage of mineral trioxide aggregate (MTA) plug and gutta-percha in short roots prepared for post placement using the bacterial penetration technique. In the presentin vitro study, 40 extracted single-rooted anterior teeth measuring 13 mm in root length were selected. Since the roots were short, 3 mm of the root length was allocated to the root canal obturation material and 10 mm of the root length was allocated to post placement. After preparation of the root canals, post spaces were prepared and the samples were randomly divided into two groups of gutta-percha and MTA. Fifteen root canals were obturated with gutta-percha and the post space was immediately prepared, with 3 mm of gutta-percha remaining in the apical end of the root canal. In 15 teeth, MTA plugs were placed, which measured 3 mm in length. The samples were placed in the Enterococcus faecalis bacterial microleakage system for 120 days. The time for the turbidity of each sample was recorded. Data were analyzed with Fisher's exact test. During the study period, turbidity was observed in all the gutta-percha samples and in only four MTA samples, with statistically significant differences between the two groups (P< 0.001). Based on the results, MTA exhibited much better sealing ability compared to gutta-percha as a root canal obturation material in teeth with short roots.

  10. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique

    Directory of Open Access Journals (Sweden)

    Jun-Qiang Wang

    2017-01-01

    Conclusions: Accuracy of the robot-assisted technique was superior to that of the freehand technique. Robot-assisted navigation is safe for unstable posterior pelvic ring stabilization, especially in S1, but also in S2. SI screw insertion with robot-assisted navigation is clinically feasible.

  11. STUDENT PLACEMENT

    African Journals Online (AJOL)

    User

    students express lack of interest in the field they are placed, it ... be highly motivated to learn than students placed in a department ... the following research questions. Research Questions. •. Did the criteria used by Mekelle. University for placement of students into different departments affect the academic performance of ...

  12. Histopathological comparative analysis of peri-implant soft tissue response after dental implant placement with flap and flapless surgical technique. Experimental study in pigs.

    Science.gov (United States)

    Vlahovic, Zoran; Markovic, Aleksa; Golubovic, Mileta; Scepanovic, Miodrag; Kalanovic, Milena; Djinic, Ana

    2015-11-01

    The aim of this study was comparing the effect of flapless vs. flap technique of implant placement on inflammation degree of peri-implant soft tissue, through histopathological analysis. The experiment was conducted on five domestic pigs. Nine weeks after tooth extraction, implants were installed. Each animal received six implants in mandible. According to split-mouth design, randomly one side was used for flapless technique using mini-incision, while on the other side, flap was raised. After 7, 14, 21, 28, and 90 days, the experimental animals were sacrificed. Samples for histopathological analyzes were taken from the buccal side of peri-implant mucosa next to the neck of implants, from three levels. The degree of inflammatory response in the peri-implant soft tissue was estimated through ordinal scores from 0 to 3. In the flap group Score 3 indicating high degree of inflammation was present from day 7 to day 21, in contrast to flapless group where Score 3 was not recorded during the entire follow-up. Three months after implantation, there were no signs of inflammation neither around flap nor around flapless implants. Flapless surgical implantation technique using mini-incision decreases peri-implant soft tissue inflammatory reaction compared with flap surgery. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Immediate Implant Placement of a Single Central Incisor Using a CAD/CAM Crown-Root Form Technique: Provisional to Final Restoration.

    Science.gov (United States)

    Vafiadis, Dean; Goldstein, Gary; Garber, David; Lambrakos, Anthony; Kowalski, Bj

    2017-02-01

    Preserving soft and hard tissues after extraction and implant placement is crucial for anterior esthetics. This technique will show how the information gathered from a cone-beam computed tomography (CBCT) scan of the maxillary left central incisor and an intra-oral digital impression can be merged to fabricate a CAD/CAM crown-root matrix to be used as an immediate provisional restoration that mimics the natural anatomy. Due to trauma, a left central incisor appeared to be fractured and was scheduled for extraction and implant placement. The crown-root configuration captured by the CBCT scan was merged with the digital files from an intra-oral digital impression. A CAD/CAM crown-root matrix was fabricated. Because the matrix shell was fabricated with the exact anatomy of the natural tooth, it replicated the position and three dimensional anatomy of the soft and hard tissue. It was connected to the implant with a customized provisional abutment. A digital impression of a coded healing abutment was made to fabricate the final implant abutment and final restoration. Throughout the treatment time and 36 months after completion, the thickness of tissue, emergence profile, and adjacent papilla was analyzed by clinical evaluation and photography and seemed to be maintained. The use of a pre-operative intra-oral digital scan of the clinical crown-root architecture and the CBCT scan of the bone/root anatomy, can be used together to fabricate a CAD/CAM crown-root form provisional matrix. This digital design helps in the preservation of the 3D tissue topography, as well as the final restoration. The preservation of soft and hard tissue after extraction and implant placement has always been paramount for ideal anterior implant esthetics. Using the information from digital files from CBCT scans and intra-oral scans may help the clinician identify critical anatomical features that can be replicated in the provisional and final CAD/CAM restoration. (J Esthet Restor Dent 29

  14. Contamination in smooth gel breast implant placement: testing a funnel versus digital insertion technique in a cadaver model.

    Science.gov (United States)

    Moyer, Hunter R; Ghazi, Bahair; Saunders, Neil; Losken, Albert

    2012-02-01

    Overt infection and biofilm formation resulting from breast augmentation are rare but serious problems that can lead to contracture and a need for revision surgery. The Keller Funnel is a medical device composed of a rip-stop nylon sleeve with a hydrophilic inner coating. One claim of the funnel is that it facilitates a "no touch" technique, thereby limiting contamination. To date, there are no data to support this claim. The authors evaluate skin and breast parenchyma contamination with standard implantation techniques and the Keller funnel. Insertion techniques were tested in two fresh cadavers. Smooth, round, moderate-plus silicone gel implants were placed for each experiment. To quantify the amount of skin contamination, a 2% w/v fluorescein paste was painted onto the cadaver thorax. After implantation, the implants were soaked in 250 mL of sterile water, and the fluorescence emission of the resulting solution was measured with an ultraviolet-visible spectrophotometer. To qualify the potential contamination from breast parenchyma, the cadaver breast tissue was swabbed with methicillin-sensitive Staphylococcus aureus, and the implant surfaces were cultured postimplantation. The funnel resulted in a 27-fold decrease in skin contact for all smooth gel implants (P = .00059). The amount of skin contact and potential contamination increased incrementally with increasing implant volume when either the funnel or digital implantation techniques were used. Bacterial contamination from breast parenchyma was two times more likely with the standard digital insertion technique (P = .06). The Keller funnel appears to significantly reduce the amount of skin contact and potential parenchyma contamination.

  15. Nasogastric tube placement into the hepaticojejunostomy anastomosis in pancreaticoduodenectomy: a simple surgical technique for prevention of bile leak.

    Science.gov (United States)

    Kaya, Bulent; Ozcabi, Yetkin; Tasdelen, Iksan; Onur, Ender; Memisoglu, Kemal

    2016-05-01

    Hepaticojejunostomy is an important part of many surgical procedures including pancreaticoduodenectomy. Biliary leakage from hepaticojejunostomy may be associated with intraabdominal abscess formation, biliary peritonitis, and even mortality. A 72-year-old female patient was admitted to our hospital with obstructive jaundice. After initial evaluation, she was diagnosed with distal common bile duct obstruction without accurate diagnosis. Before planned pancreaticoduodenectomy, biliary drainage with a T-tube was performed due to the presence of cholangitis. After the first operation, pancreaticoduodenectomy was performed. Postinflammatory changes around the hilar region made the hepaticojejunostomy risky. A bilio-digestive anastomosis was performed using a new technique. A nasogastric tube was placed into the common bile duct proximal to the anastomosis. The postoperative course of the patient was uneventful. The use of a nasogastric tube as a stent in risky hepaticojejunostomies is a simple technique that can be beneficial.

  16. Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques.

    Science.gov (United States)

    Silbermann, J; Riese, F; Allam, Y; Reichert, T; Koeppert, H; Gutberlet, M

    2011-06-01

    Transpedicular screw fixation has been accepted worldwide since Harrington et al. first placed pedicle screws through the isthmus. In vivo and in vitro studies indicated that pedicle screw insertion accuracy could be significantly improved with image-assisted systems compared with conventional approaches. The O-arm is a new generation intraoperative imaging system designed without compromise to address the needs of a modern OR like no other system currently available. The aim of our study was to check the accuracy of O-arm based and S7-navigated pedicle screw implants in comparison to free-hand technique described by Roy-Camille at the lumbar and sacral spine using CT scans. The material of this study was divided into two groups, free-hand group (group I) (30 patients; 152 screws) and O-arm group (37 patients; 187 screws). The patients were operated upon from January to September 2009. Screw implantation was performed during PLIF or TLIF mainly for spondylolisthesis, osteochondritis and post-laminectomy syndrome. The accuracy rate in our work was 94.1% in the free-hand group compared to 99% in the O-arm navigated group. Thus it was concluded that free-hand technique will only be safe and accurate when it is in the hands of an experienced surgeon and the accuracy of screw placement with O-arm can reach 100%.

  17. Wood pole overhead lines

    CERN Document Server

    Wareing, Brian

    2005-01-01

    This new book concentrates on the mechanical aspects of distribution wood pole lines, including live line working, environmental influences, climate change and international standards. Other topics include statutory requirements, safety, profiling, traditional and probabilistic design, weather loads, bare and covered conductors, different types of overhead systems, conductor choice, construction and maintenance. A section has also been devoted to the topic of lightning, which is one of the major sources of faults on overhead lines. The book focuses on the effects of this problem and the strate

  18. Effect of Materials and Manufacturing on the Bending Stiffness of Vaulting Poles

    Science.gov (United States)

    Davis, C. L.; Kukureka, S. N.

    2012-01-01

    The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP)…

  19. Private placements

    International Nuclear Information System (INIS)

    Bugeaud, G. J. R.

    1998-01-01

    The principles underlying private placements in Alberta, and the nature of the processes employed by the Alberta Securities Commission in handling such transactions were discussed. The Alberta Securities Commission's mode of operation was demonstrated by the inclusion of various documents issued by the Commission concerning (1) special warrant transactions prior to listing, (2) a decision by the Executive Director refusing to issue a receipt for the final prospectus for a distribution of securities of a company and the reasons for the refusal, (3) the Commission's decision to interfere with the Executive Director's decision not to issue a receipt for the final prospectus, with full citation of the Commission's reasons for its decision, (4) and a series of proposed rules and companion policy statements regarding trades and distributions outside and in Alberta. Text of a sample 'short form prospectus' was also included

  20. Sediment Placement Areas 2012

    Data.gov (United States)

    California Department of Resources — Dredge material placement sites (DMPS), including active, inactive, proposed and historical placement sites. Dataset covers US Army Corps of Engineers San Francisco...

  1. Study on pedicle screw fixation of cervical spine assisted CT-based navigation system compared with the individual cervical peddle screws placement technique

    International Nuclear Information System (INIS)

    He Xishun; Yang Huilin; Zhu Ruofu; Tan Xiangqi; Wang Genlin; Tang Tiansi

    2008-01-01

    Objective: To explore a safe and effective method for placing the cervical pedicle screws. Methods: There were ten adult cadaver specimens of cervica spine (C 1 -C 7 ) with intact structures including ligament and perivertebral muscles. The spiral computed tomography scan (Elscint CT Twin flash) at the section of 1 mm and three-dimensional reconstruction of all 10 cervical specimens were taken. By CT scan, the parameters of the cervical pedicles were measure,Then taking randomly 5 cervical specimens, according to the CT measurements, an appropriate screw was inserted into pedicle individually. In the other 5 human cadaver cervical vertebraes, Φ3.5 mm screws were inserted into the C 2 -C 7 pedicles by assisted by CT-based navigation system. Cortical integrity of every sample was examined by anatomic dissection, the spiral computed tomography scan and arrows,and coronal reconstruction. Results: Sixty screws was inserted into pedicle individually, and the achievement ratio was 90%, the perfectness ratio was 75%, 60 screws was placed into pedicle assisted by CT-based navigation system, and the achievement ratio was 96.6%, the perfectness ratio was 90%. By chi-square test for statistical analysis, there were no statistical significance between the accuracy rate of two methods(P>0.05). However there was statistical significance between the perfectness ratio between two methods(P<0.05). Conclusion: Compared with the individual cervical peddle screws placement technique, the perfectness ratio of pedicle screw fixation of cervical spine assisted by CT-based navigation system is higher, but there are no significant difference in accuracy. (authors)

  2. Optimal pole shifting controller for interconnected power system

    International Nuclear Information System (INIS)

    Yousef, Ali M.; Kassem, Ahmed M.

    2011-01-01

    Research highlights: → Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. → Power system stabilizer was designed based on optimal pole shifting controller. → The system performances was tested through load disturbances at different operating conditions. → The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. → The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for shifting one real pole or two complex conjugate poles, respectively. This presented method yields a solution, which is optimal with respect to a quadratic performance index. The attractive feature of this method is that it enables solutions of the complex problem to be easily found without solving any non-linear algebraic Riccati equation. The present power system stabilizer is based on Riccati equation approach. The control law depends on finding the feedback gain matrix, and then the control signal is synthesized by multiplying the state variables of the power system with determined gain matrix. The gain matrix is calculated one time only, and it works over wide range of operating conditions. To validate the power of the proposed PSS, a linearized model of a simple power system consisted of a single synchronous machine connected to infinite bus bar through transmission line is simulated. The studied power system is subjected to various operating points and power system parameters changes.

  3. Clinical outcomes of secondary gastroduodenal self-expandable metallic stent placement by stent-in-stent technique for malignant gastric outlet obstruction.

    Science.gov (United States)

    Sasaki, Takashi; Isayama, Hiroyuki; Nakai, Yousuke; Takahara, Naminatsu; Hamada, Tsuyoshi; Mizuno, Suguru; Mohri, Dai; Yagioka, Hiroshi; Kogure, Hirofumi; Arizumi, Toshihiko; Togawa, Osamu; Matsubara, Saburo; Ito, Yukiko; Yamamoto, Natsuyo; Sasahira, Naoki; Hirano, Kenji; Toda, Nobuo; Tada, Minoru; Koike, Kazuhiko

    2015-01-01

    To evaluate the efficacy and safety of secondary gastroduodenal stent placement after first stent dysfunction for malignant gastric outlet obstruction. We conducted a retrospective analysis to investigate the efficacy and safety of secondary stent-in-stent gastroduodenal stent placement. Among 260 patients who had been treated with first gastroduodenal stent placement for malignant gastric outlet obstruction, 29 patients (11.2%) were treated with secondary gastroduodenal stent placement because of first stent dysfunction. Pancreatic cancer was the major primary cancer (55.2%). A WallFlex duodenal stent was the most frequently inserted stent both as a first stent (75.9%) and as a secondary stent (62.1%). There were 22 patients (75.9%) that received gastroduodenal stents at the bending site (supraduodenal angle or infraduodenal angle). Technical and clinical success rates were 100% and 86.2%, respectively. Median eating period was 3.0 months, and median survival time was 3.5 months. As for related complications, gastrointestinal perforation, insufficient stent expansion, tumor ingrowth, tumor overgrowth, and cholangitis were experienced in 13.8% (four cases), 6.9% (two cases), 6.9% (two cases), 3.4% (one case), and 3.4% (one case), respectively. Secondary gastroduodenal stent placement might be effective for managing first stent dysfunction in malignant gastric outlet obstruction. However, gastrointestinal perforation was the major complication. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  4. Anterior single odontoid screw placement for type II odontoid fractures: our modified surgical technique and initial results in a cohort study of 15 patients [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Sunil Munakomi

    2016-11-01

    Full Text Available Objective: Anterior odontoid screw fixation for type II odontoid fracture is the ideal management option. However in the context of unavailability of an O-arm or neuro-navigation and poor images from the available C-arm may be an obstacle to ideal trajectory and placement of the odontoid screw. We herein detail  our surgical technique so as to ensure a correct trajectory and subsequent good fusion in Type II odontoid fractures. This may be advantageous  in clinical set ups lacking state of the art facilities.  Methods and Results: In this cohort study we included 15 consecutive patients who underwent anterior odontoid screw placement. We routinely dissect the longus colli to completely visualize the entire width of C3 body. We then perform a median C2-C3 disectomy followed by creating a gutter in the superior end of C3 body. We then guide the Kirchsner (K wire purchasing adequate anterior cortex of C2. Rest of the procedure follows the similar steps as described for odontoid screw placement. We achieved 100% correct trajectory and screw placement in our study. There were no instances of screw break out, pull out or nonunion. There was one patient mortality following myocardial infarction in our study. Conclusion: Preoperative imaging details, proper patient positioning, meticulous dissection, thorough anatomical knowledge and few added surgical nuances are the cornerstones in ideal odontoid screw placement. This may be pivotal in managing  patients in developing nations having rudimentary neurosurgical set up.

  5. The South Pole Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Ruhl, J.E.; Ade, P.A.R.; Carlstrom, J.E.; Cho, H.M.; Crawford,T.; Dobbs, M.; Greer, C.H.; Halverson, N.W.; Holzapfel, W.L.; Lanting,T.M.; Lee, A.T.; Leitch, E.M.; Leong, J.; Lu, W.; Lueker, M.; Mehl, J.; Meyer, S.S.; Mohr, J.J.; Padin, S.; Plagge, T.; Pryke, C.; Runyan, M.C.; Schwan, D.; Sharp, M.K.; Spieler, H.; Staniszewski, Z.; Stark, A.A.

    2004-11-04

    A new 10 meter diameter telescope is being constructed for deployment at the NSF South Pole research station. The telescope is designed for conducting large-area millimeter and sub-millimeter wave surveys of faint, low contrast emission, as required to map primary and secondary anisotropies in the cosmic microwave background. To achieve the required sensitivity and resolution, the telescope design employs an off-axis primary with a 10 m diameter clear aperture. The full aperture and the associated optics will have a combined surface accuracy of better than 20 microns rms to allow precision operation in the submillimeter atmospheric windows. The telescope will be surrounded with a large reflecting ground screen to reduce sensitivity to thermal emission from the ground and local interference. The optics of the telescope will support a square degree field of view at 2mm wavelength and will feed a new 1000-element micro-lithographed planar bolometric array with superconducting transition-edge sensors and frequency-multiplexed readouts. The first key project will be to conduct a survey over 4000 degrees for galaxy clusters using the Sunyaev-Zeldovich Effect. This survey should find many thousands of clusters with a mass selection criteria that is remarkably uniform with redshift. Armed with redshifts obtained from optical and infrared follow-up observations, it is expected that the survey will enable significant constraints to be placed on the equation of state of the dark energy.

  6. Glass Waveguides for Periodic Poling

    DEFF Research Database (Denmark)

    Fage-Pedersen, Jacob; Jacobsen, Rune Shim; Kristensen, Martin

    2005-01-01

    Planar silica-based waveguide devices have been developed for second-harmonic generation by poling with periodic electrodes. We show that detrimental charge transport can occur along interfaces, but with proper choice of fabrication, high-quality devices are obtained.......Planar silica-based waveguide devices have been developed for second-harmonic generation by poling with periodic electrodes. We show that detrimental charge transport can occur along interfaces, but with proper choice of fabrication, high-quality devices are obtained....

  7. Boat boarding ladder placement

    Science.gov (United States)

    1998-04-01

    Presented in three volumes; 'Boat Boarding Ladder Placement,' which explores safety considerations including potential for human contact with a rotating propeller; 'Boat Handhold Placement,' which explores essential principles and methods of fall con...

  8. A Placement Advisory Test

    Science.gov (United States)

    Hughes, Chris

    2010-01-01

    The primary method of placement at Portland CC (PCC) is the Compass Placement test. For the most part, students are placed correctly, but there are cases when students feel that they have been placed too low. In such cases we use our newly created Placement Advisory Test (PAT) to help us place them appropriately. (Contains 2 figures.)

  9. Optimal placement of capacito

    Directory of Open Access Journals (Sweden)

    N. Gnanasekaran

    2016-06-01

    Full Text Available Optimal size and location of shunt capacitors in the distribution system plays a significant role in minimizing the energy loss and the cost of reactive power compensation. This paper presents a new efficient technique to find optimal size and location of shunt capacitors with the objective of minimizing cost due to energy loss and reactive power compensation of distribution system. A new Shark Smell Optimization (SSO algorithm is proposed to solve the optimal capacitor placement problem satisfying the operating constraints. The SSO algorithm is a recently developed metaheuristic optimization algorithm conceptualized using the shark’s hunting ability. It uses a momentum incorporated gradient search and a rotational movement based local search for optimization. To demonstrate the applicability of proposed method, it is tested on IEEE 34-bus and 118-bus radial distribution systems. The simulation results obtained are compared with previous methods reported in the literature and found to be encouraging.

  10. Iron Pole Shape Optimization of IPM Motors Using an Integrated Method

    Directory of Open Access Journals (Sweden)

    JABBARI, A.

    2010-02-01

    Full Text Available An iron pole shape optimization method to reduce cogging torque in Interior Permanent Magnet (IPM motors is developed by using the reduced basis technique coupled by finite element and design of experiments methods. Objective function is defined as the minimum cogging torque. The experimental design of Taguchi method is used to build the approximation model and to perform optimization. This method is demonstrated on the rotor pole shape optimization of a 4-poles/24-slots IPM motor.

  11. Are success and survival rates of early implant placement higher than immediate implant placement?

    Science.gov (United States)

    Soydan, S S; Cubuk, S; Oguz, Y; Uckan, S

    2013-04-01

    Immediate placement refers to the placement of an implant into a tooth socket at the time of extraction; early placement refers to the placement of an implant after substantial gingival healing, but before any clinically significant bone fill occurs within the socket. This study evaluated the success and survival rates of implants following immediate and early placement. 50 implants were placed in 36 patients. 26 immediate (group I) and 24 early placements (group II) were performed. Pain or tenderness with function, mobility, radiographic bone loss from initial surgery and exudate history were evaluated. Mean vertical bone loss in the immediate placement group was 0.55 mm and 0.80 mm in the early placement group. The survival rate for the immediate placement group was 96.16% with 51.6 months follow-up and in the early placement group was 100% with 61.9 months follow-up. The results of this study suggest that although the success and survival rates of early placed implants were a little higher and the follow up period was longer than immediately placed implants, the difference was not remarkable. In conclusion, both implant insertion techniques are safe and reliable procedures with considerably high survival rates. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Glass Waveguides for Periodic Poling

    DEFF Research Database (Denmark)

    Fage-Pedersen, Jacob; Jacobsen, Rune Shim; Kristensen, Martin

    2005-01-01

    Planar silica-based waveguide devices have been developed for second-harmonic generation by poling with periodic electrodes. We show that detrimental charge transport can occur along interfaces, but with proper choice of fabrication, high-quality devices are obtained....

  13. A ZMP-Compensation Method Based on Pole-Zero Cancellation for Biped Robots

    Science.gov (United States)

    Shimmyo, Shuhei; Ohnishi, Kouhei

    This paper proposes a ZMP-compensation method based on pole-zero cancellation for biped robots. Conventionally, walking stabilization controls is achieved by using the feedback of ZMP error. In these systems, several feedback gains need to be determined, and this is done by using the optimal control theory or the pole-placement method. In the proposed method, only one feedback gain needs to be determined. Therefore, the proposed method makes it easy to design a walking stabilization controller. The effectiveness of the proposed method is confirmed from the results of simulations and experiments.

  14. Kick, Glide, Pole! Cross-Country Skiing Fun (Part II)

    Science.gov (United States)

    Duoos, Bridget A.

    2012-01-01

    Part I of Kick, Glide, Pole! Cross-Country Skiing Fun, which was published in last issue, discussed how to select cross-country ski equipment, dress for the activity and the biomechanics of the diagonal stride. Part II focuses on teaching the diagonal stride technique and begins with a progression of indoor activities. Incorporating this fun,…

  15. Carrier Phase GPS Navigation to the North Pole

    Science.gov (United States)

    Moore, T.; Roberts, G. W.

    Over the last few years, on-the-fly integer ambiguity resolution for GPS has proven to be successful over short baselines (500 km. New techniques have been developed at the University of Nottingham to allow very long baseline integer ambiguity resolution, on-the-fly. A major problem with the use of carrier phase data is that posed by cycle slips. A technique for detecting and correcting cycle slips has been developed, and its use is discussed in this paper. The new technique has been proven through a series of trials, one of which included two flights to the North Pole, performing centimetric level positioning all the way to the pole. For many years, the GD Aero-Systems Course of the Air Warfare Centre based at RAF Cranwell executed a series of equipment flight trials to the North Pole, called the ARIES Flights. In May 1996, the authors were fortunate to take part in both flights, via Iceland and Greenland, to the North Pole. Based on reference stations at Thule Air Base, integer ambiguity resolution was accomplished, on-the-fly, and centimetric level navigation maintained throughout the flights. Earlier trials detailed in the paper demonstrate that the technique can resolve integer ambiguities on-the-fly within a few seconds over a baseline length of approximately 134 km, resulting in an accuracy of 12 cm. The majority of the residual error source for this being the ionosphere.

  16. Biomechanical characteristics and speed adaptation during kick double poling on roller skis in elite cross-country skiers.

    Science.gov (United States)

    Göpfert, Caroline; Holmberg, Hans-Christer; Stöggl, Thomas; Müller, Erich; Lindinger, Stefan Josef

    2013-06-01

    Recent developments in cross-country ski racing should promote the use of kick double poling. This technique, however, has not been the focus in athletes' training and has barely been investigated. The aims of the present study were to develop a function-based phase definition and to analyse speed adaptation mechanisms for kick double poling in elite cross-country skiers. Joint kinematics and pole/plantar forces were recorded in 10 athletes while performing kick double poling at three submaximal roller skiing speeds. A speed increase was associated with increases in cycle length and rate, while absolute poling and leg push-off durations shortened. Despite maintained impulses of force, the peak and average pole/leg forces increased. During double poling and leg push-off, ranges of motion of elbow flexion and extension increased (p aspects for technique training.

  17. 47 CFR 32.6411 - Poles expense.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Poles expense. 32.6411 Section 32.6411... FOR TELECOMMUNICATIONS COMPANIES Instructions for Expense Accounts § 32.6411 Poles expense. This account shall include expenses associated with poles. ...

  18. Multiobjective H2/H? Control Design with Regional Pole Constraints

    Directory of Open Access Journals (Sweden)

    Junaidi Junaidi

    2012-03-01

    Full Text Available This paper presents multiobjective H2/H? control design with regional pole constraints. The state feedback gain can be obtained by solving a linear matrix inequality (LMI feasibility problem that robustly assigns the closed-loop poles in a prescribed LMI region. The proposed technique is illustrated with applications to the design of stabilizer for a typical single-machine infinite-bus (SMIB power system. The LMI-based control ensures adequate damping for widely varying system operating conditions. The simulation results illustrate the effectiveness and robustness of the proposed stabilizer.

  19. Pole counting and resonance classification

    International Nuclear Information System (INIS)

    Morgan, D.

    1992-01-01

    S-wave resonances occurring close to an inelastic threshold can be classified according to the number of nearby poles they possess. One then has a useful possibility of distinguishing dynamical alternatives by objective appeal to data. Making this quantitative entails developing suitable effective range expansions for various realizations of potential scattering. A key application is deciding the make-up of f 0 (976) (S*). (author)

  20. Single Sitting Surgical Treatment of Generalized Aggressive Periodontitis Using GTR Technique and Immediate Implant Placement with 10-Year Follow-Up

    Directory of Open Access Journals (Sweden)

    Fatme Mouchref Hamasni

    2018-01-01

    Full Text Available This case report exhibits a patient with generalized aggressive periodontitis who has been under maintenance for the past 12 years after being surgically treated in a single sitting and restored with dental implants. A 41-year-old systemically healthy male patient presented complaining of lower anterior teeth mobility and pain in the upper right quadrant. After clinical and radiographic examination, the upper right molars and lower anterior incisors were deemed unrestorable. Covered by doxycycline, the patient received a nonsurgical periodontal treatment. Three weeks later, teeth extraction, immediate implant placement, immediate nonloading provisional prosthesis, and a guided tissue regeneration were performed at indicated areas in a single sitting. The clinical decisions were based on patient compliance, the status of the existing periodontal tissues, and the prognosis of the remaining teeth. During the 12-year follow-up period, no residual pockets were observed and there was no exacerbation of the inflammatory condition. Marginal bone stability is present on all implants. For aggressive periodontal disease, a high risk of relapse as well as limited success and survival of dental implants should be considered. This case shows proper containment of the disease based on appropriate treatment planning and a strict maintenance program.

  1. Investigation of bacteremia after separator placement

    Directory of Open Access Journals (Sweden)

    Anjuman Preet Kaur Dua

    2016-01-01

    Full Text Available Background: Simple orthodontic procedure such as separator placement can be associated with the occurrence of transient bacteraemia. Use of clorhexidine before separator placement has been recommended as a measure to decrease the bacteraemia. Aim: The purpose of this study was to detect the presence of transient bacteremia after separator placement following use of 0.2% chlorhexidine gluconate mouthwash. Methodology: The study group consisted of 27 adult patients who reported for orthodontic treatment (18 males and 9 females. The patients were asked to rinse their mouth for 60 sec with 15 mL of 0.2% chlorhexidine gluconate mouthwash before the separator placement. An aseptic technique was used to draw out 5 ml of blood was from either the left or right antecubital fossa immediately before orthodontic separator placement (as control group, and the second 5 ml sample was taken 1–2 min after the placement of separators mesial and distal to all the first molars. All the blood samples were inoculated into culture bottles containing Brain Heart Infusion and incubated aerobically for 7 days. Media used for bacterial growth is chocolate agar and MacConkey agar. Results: From a total of 27 patients and 54 samples, none of the sample was found positive for bacteremia. Conclusion: This study demonstrated that there is no bacteremia after the placement of separators following the use of chlorhexidine mouthwash.

  2. Design and development of a wireless sensor network to monitor snow depth in multiple catchments in the American River basin, California: hardware selection and sensor placement techniques

    Science.gov (United States)

    Kerkez, B.; Rice, R.; Glaser, S. D.; Bales, R. C.; Saksa, P. C.

    2010-12-01

    A 100-node wireless sensor network (WSN) was designed for the purpose of monitoring snow depth in two watersheds, spanning 3 km2 in the American River basin, in the central Sierra Nevada of California. The network will be deployed as a prototype project that will become a core element of a larger water information system for the Sierra Nevada. The site conditions range from mid-elevation forested areas to sub-alpine terrain with light forest cover. Extreme temperature and humidity fluctuations, along with heavy rain and snowfall events, create particularly challenging conditions for wireless communications. We show how statistics gathered from a previously deployed 60-node WSN, located in the Southern Sierra Critical Zone Observatory, were used to inform design. We adapted robust network hardware, manufactured by Dust Networks for highly demanding industrial monitoring, and added linear amplifiers to the radios to improve transmission distances. We also designed a custom data-logging board to interface the WSN hardware with snow-depth sensors. Due to the large distance between sensing locations, and complexity of terrain, we analyzed network statistics to select the location of repeater nodes, to create a redundant and reliable mesh. This optimized network topology will maximize transmission distances, while ensuring power-efficient network operations throughout harsh winter conditions. At least 30 of the 100 nodes will actively sense snow depth, while the remainder will act as sensor-ready repeaters in the mesh. Data from a previously conducted snow survey was used to create a Gaussian Process model of snow depth; variance estimates produced by this model were used to suggest near-optimal locations for snow-depth sensors to measure the variability across a 1 km2 grid. We compare the locations selected by the sensor placement algorithm to those made through expert opinion, and offer explanations for differences resulting from each approach.

  3. Method and apparatus for assembling a permanent magnet pole assembly

    Science.gov (United States)

    Carl, Jr., Ralph James; Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Dawson, Richard Nils [Voorheesville, NY; Qu, Ronghai [Clifton Park, NY; Avanesov, Mikhail Avramovich [Moscow, RU

    2009-08-11

    A pole assembly for a rotor, the pole assembly includes a permanent magnet pole including at least one permanent magnet block, a plurality of laminations including a pole cap mechanically coupled to the pole, and a plurality of laminations including a base plate mechanically coupled to the pole.

  4. Effect of materials and manufacturing on the bending stiffness of vaulting poles

    Science.gov (United States)

    Davis, C. L.; Kukureka, S. N.

    2012-09-01

    The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP) composites. The lighter GFRP pole enabled the athletes to have a faster run-up, resulting in a greater take-off speed, giving them more kinetic energy to convert into potential energy and hence height. GFRP poles also have a much higher failure stress than bamboo, so the poles were engineered to bend under the load of the athlete, thereby storing elastic strain energy that can be released as the pole straightens, resulting in greater energy efficiency. The bending also allowed athletes to change their vaulting technique from a style that involved the body remaining almost upright during the vault to one where the athlete goes over the bar with their feet upwards. Modern vaulting poles can be made from GFRP and/or carbon fibre reinforced polymer (CFRP) composites. The addition of carbon fibres maintains the mechanical properties of the pole, but allows a reduction in the weight. The number and arrangement of the fibres determines the mechanical properties, in particular the bending stiffness. Vaulting poles are also designed for an individual athlete to take into account each athlete’s ability and physical characteristics. The poles are rated by ‘weight’ to allow athletes to select an appropriate pole for their ability. This paper will review the development of vaulting poles and the requirements to maximize performance. The properties (bending stiffness and pre-bend) and microstructure (fibre volume fraction and lay-up) of typical vaulting poles will be discussed. Originally published as Davis C L and Kukureka S N (2004) Effect of materials and manufacturing on the bending stiffness of vaulting poles The Engineering of

  5. ESL Placement and Schools

    Science.gov (United States)

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra; Frisco, Michelle

    2010-01-01

    In this study, the authors explore English as a Second Language (ESL) placement as a measure of how schools label and process immigrant students. Using propensity score matching and data from the Adolescent Health and Academic Achievement Study and the National Longitudinal Study of Adolescent Health, the authors estimate the effect of ESL placement on immigrant achievement. In schools with more immigrant students, the authors find that ESL placement results in higher levels of academic performance; in schools with few immigrant students, the effect reverses. This is not to suggest a one-size-fits-all policy; many immigrant students, regardless of school composition, generational status, or ESL placement, struggle to achieve at levels sufficient for acceptance to a 4-year university. This study offers several factors to be taken into consideration as schools develop policies and practices to provide immigrant students opportunities to learn. PMID:20617111

  6. [A cadaveric study on establishing an individualized navigation template for the placement of occipital condyle screws using a three-dimensional printing technique].

    Science.gov (United States)

    Huang, Xuan; Li, Fengning; Zhang, Fan; Wang, Kun; Yang, Qingsong; Dang, Ruishan; Su, Jiacan; Shen, Hongxing; Li, Ming

    2014-07-01

    To investigate the feasibility of establishing an individualized navigation template for occipital condyle screws insertion using a fused deposition modeling based three-dimensional printing forming technique, and to evaluate the accuracy and safety of template-assisted condyle screw insertion. Thirty adult occipitocervical specimens were selected to take a CT-scan. After original Dicom data imported into the Mimics software, the craniocervical junction models were created, which were used to evaluate anatomic structures and define the screw-related parameters. Design and generate the cavity models of the occipital condyle based on a three-dimensional printing forming technique. After using a free-hand procedure to create a navigation template with a well-established screw path, finish bilateral condyle screws insertion assisted by the navigation template. Anatomy study and CT-scan were taken postoperatively to access the position of the screws. Sixty condyle screws were implanted assisted by 30 individualized navigation templates with an average time cost of (91.4 ± 8.2) s. The axial medial angle, sagittal cranial angle and distance between the entry point to atlantooccipital joint surface were (33.2 ± 6.4)°, (8.9 ± 3.4)°, (3.9 ± 0.9) mm, respectively. The variations due to different sex and sides resulted in a statistically insignificant difference of the parameters. Anatomy study and CT-scan indicated no intrusion of the vertebral artery, hypoglossal canal, condyle emissary vein canal or atlantooccipital joint. Fifty-nine condyle screws were completely contained within the condyle, while only 1 screw perforated lateral condyle wall. Using the Mimics software for establishing the occipital condyle and related cavity model based on CT-scan images proves to be a feasible and precise method.Occipital condyle screws insertion assisted by a three-dimensional printing model is highly accurate and simple, which could be a new alternative to conventional technique.

  7. Fine Control of Local Whitespace in Placement

    Directory of Open Access Journals (Sweden)

    Jarrod A. Roy

    2008-01-01

    Full Text Available In modern design methodologies, a large fraction of chip area during placement is left unused by standard cells and allocated as “whitespace.” This is done for a variety of reasons including the need for subsequent buffer insertion, as a means to ensure routability, signal integrity, and low coupling capacitance between wires, and to improve yield through DFM optimizations. To this end, layout constraints often require a certain minimum fraction of whitespace in each region of the chip. Our work introduces several techniques for allocation of whitespace in global, detail, and incremental placement. Our experiments show how to efficiently improve wirelength by reallocating whitespace in legal placements at the large scale. Additionally, for the first time in the literature, we empirically demonstrate high-precision control of whitespace in designs with macros and obstacles. Our techniques consistently improve the quality of whitespace allocation of top-down as well as analytical placement methods and achieve low penalties on designs from the ISPD 2006 placement contest with minimal interconnect increase.

  8. Product Placement in Cartoons

    Directory of Open Access Journals (Sweden)

    Irena Oroz Štancl

    2014-06-01

    Full Text Available Product placement is a marketing approach for integrating products or services into selected media content. Studies have shown that the impact of advertising on children and youth are large, and that it can affect their preferences and attitudes. The aim of this article is to determine the existing level of product placement in cartoons that are broadcast on Croatian television stations. Content analysis of cartoons in a period of one month gave the following results: in 30% of cartoons product placement was found; most product placement were visual ads, in 89%, however, auditory product placement and plot connection was also found. Most ads were related to toys and it is significant that even 65% of cartoons are accompanied by a large amount of products available on the Croatian market. This is the result of two sales strategies: brand licensing (selling popular cartoon characters to toys, food or clothing companies and cartoon production based on existing line of toys with the sole aim of making their sales more effective.

  9. Macro Fiber Piezocomposite Actuator Poling Study

    Science.gov (United States)

    Werlink, Rudy J.; Bryant, Robert G.; Manos, Dennis

    2002-01-01

    The performance and advantages of Piezocomposite Actuators are to provide a low cost, in-situ actuator/sensor that is flexible, low profile and high strain per volt performance in the same plane of poled voltage. This paper extends reported data for the performance of these Macrofiber Composite (MFC) Actuators to include 4 progressively narrower Intedigitized electrode configurations with several line widths and spacing ratios. Data is reported for max free strain, average strain per applied volt, poling (alignment of the electric dipoles of the PZT ceramic) voltage vs. strain and capacitance, time to poling voltage 95% saturation. The output strain per volt progressively increases as electrode spacing decreases, with saturation occurring at lower poling voltages. The narrowest spacing ratio becomes prone to voltage breakdown or short circuits limiting the spacing width with current fabrication methods. The capacitance generally increases with increasing poling voltage level but has high sensitivity to factors such as temperature, moisture and time from poling which limit its usefulness as a simple indicator. The total time of applied poling voltage to saturate or fully line up the dipoles in the piezoceramic was generally on the order of 5-20 seconds. Less sensitivity to poling due to the applied rate of voltage increase over a 25 to 500 volt/second rate range was observed.

  10. Strength of single-pole utility structures

    Science.gov (United States)

    Ronald W. Wolfe

    2006-01-01

    This section presents three basic methods for deriving and documenting Rn as an LTL value along with the coefficient of variation (COVR) for single-pole structures. These include the following: 1. An empirical analysis based primarily on tests of full-sized poles. 2. A theoretical analysis of mechanics-based models used in...

  11. In vivo evaluation of crestal bone heights following implant placement with ′flapless′ and ′with-flap′ techniques in sites of immediately loaded implants

    Directory of Open Access Journals (Sweden)

    Job Shibu

    2008-01-01

    Full Text Available Purpose: To evaluate and compare the changes in crestal bone height around implants placed with flapless surgery and with-flap surgery. Materials and Methods: Ten implants were placed in six patients - five using flapless and five using with-flap techniques. Single-piece root-form implants and a one-stage approach with immediate nonfunctional loading protocol were used. The change in heights of crestal bone was measured on standardized digital periapical radiographs taken at 0, 1, and 3 months. Results: On mesial side, the mean change from months 0-1, months 1-3, and months 0-3 for flapless method was significantly lower than with-flap method [0.01-0.06 mm for flapless and 0.13-0.40 mm for with-flap ( P = 0.01]. On the distal side, the mean change from months 0-1, months 1-3, and months 0-3 for flapless method was significantly lower than with-flap method [0.02-0.05 mm for flapless and 0.09-0.30 mm for with-flap ( P = 0.01]. Conclusions: During the three-month period, reduction of crestal bone height around the implants placed with flapless surgery (0.06 mm was not statistically significant, while the reduction of crestal bone height around the implants placed using with-flap surgery (0.4 mm was statistically significant. Comparitively, flapless approach showed lesser crestal bone height reduction, which was statistically significant.

  12. Planar glass devices for efficient periodic poling

    DEFF Research Database (Denmark)

    Fage-Pedersen, Jacob; Jacobsen, Rune Shim; Kristensen, Martin

    2005-01-01

    We demonstrate that frequency-converting devices of high quality can be realised with glass poling. The devices, made with silica-on-silicon technology, are poled with periodic, embedded electrodes, and used for second-harmonic generation. We obtain precise control of the quasi phase-matching wav......We demonstrate that frequency-converting devices of high quality can be realised with glass poling. The devices, made with silica-on-silicon technology, are poled with periodic, embedded electrodes, and used for second-harmonic generation. We obtain precise control of the quasi phase......-matching wavelength and bandwidth, and a normalised conversion efficiency of 1.4×10-3 %/W/cm2 which, to our knowledge, is the highest obtained so far with periodic glass poling....

  13. Metrópoles desgovernadas

    Directory of Open Access Journals (Sweden)

    Erminia Maricato

    2011-04-01

    Full Text Available Apesar de sua importância econômica, política, social, demográfica, cultural, territorial e ambiental, há, nas metrópoles brasileiras, uma significativa falta de governo, evidenciada pelas incipientes iniciativas de cooperação administrativa intermunicipal e federativa. Este artigo aborda as mudanças estruturais - no processo de urbanização/ metropolização - devidas à reestruturação produtiva do capitalismo global, e, na escala nacional, trata da mudança no marco institucional - jurídico/político - que passou de concentrador e centralizador, durante o regime militar, para descentralizador e esvaziado, após a Constituição de 1988. O recuo verificado nas políticas sociais durante os anos 1980 e 1990, notadamente em transporte, habitação e saneamento, além do desmonte dos organismos metropolitanos, conduziu nossas metrópoles a um destino de banalização das tragédias urbanas. Em que pese sua urgência, a questão metropolitana não sensibiliza nenhuma força política ou instituição que lhe atribua lugar de destaque na agenda nacional.Despite its economic, political, social, demographic, cultural, territorial and environmental importance, there is a significant lack of government in the brazilian metropolises, evidenced by the incipient initiatives of intermunicipal and federative administrative cooperation. This article analyses the structural changes - in the process of urbanization/metropolization - due to the productive restructuring of global capitalism, and, in a national scale, analyses the change in the institutional mark - legal/political - which passed from concentrator and centralizer, during the Military Regimen, to decentralized and emptied, after 1988 Constitution. The downturn verified in social policies during the years 1980 and 1990, notably in transport, housing and sanitation, besides the dismantling of the metropolitan agencies, has led our cities to the trivialization of urban tragedies. Despite

  14. Multiple immediate implants placement with immediate loading.

    Science.gov (United States)

    Narang, Sumit; Narang, Anu; Jain, Kapil; Bhatia, Vineet

    2014-09-01

    The replacement of missing teeth with implant-borne restorations has become a treatment modality accepted by the scientific community for fully and partially edentulous patients. Recent reports have demonstrated the successful placement of dental implants into the fresh extraction socket in the anterior as well as in molar regions, which is made possible due to modification in implant surface. The present case report highlights the placement of three bicortical screw (BCS) implants into the fresh extraction sockets and one KOS implant in edentulous area with flapless technique. All the implants were immediately loaded and followed up for a period of 6 months.

  15. Multiple immediate implants placement with immediate loading

    Directory of Open Access Journals (Sweden)

    Sumit Narang

    2014-01-01

    Full Text Available The replacement of missing teeth with implant-borne restorations has become a treatment modality accepted by the scientific community for fully and partially edentulous patients. Recent reports have demonstrated the successful placement of dental implants into the fresh extraction socket in the anterior as well as in molar regions, which is made possible due to modification in implant surface. The present case report highlights the placement of three bicortical screw (BCS implants into the fresh extraction sockets and one  KOS implant in edentulous area with flapless technique. All the implants were immediately loaded and followed up for a period of 6 months.

  16. Performance analysis of variable speed multiphase induction motor with pole phase modulation

    Directory of Open Access Journals (Sweden)

    Liu Huijuan

    2016-09-01

    Full Text Available The pole phase modulation (PPM technique is an effective method to extend speed range and torque capabilities for an integrated starter and hybrid electric vehicles applications. In this paper, the five pole-phase combination types of a multiphase induction motor (IM with 36 stator slots and 36 stator conductors are presented and compared quantitatively by using the time-stepping finite element method (TS-FEM. The 36 stator conductors of the proposed multiphase IM are fed by a 36 leg inverter and the current phase angle and amplitude of each stator conductor can be controlled independently. This paper focuses on the winding connection, the PPM technique and the performance comparative analysis of each pole-phase combination types of the proposed multiphase IM. The flux distribution, air-gap flux density, output torque, core losses and efficiency of five pole-phase combination types have been investigated.

  17. FtsZ placement in nucleoid-free bacteria.

    Directory of Open Access Journals (Sweden)

    Manuel Pazos

    Full Text Available We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO. A second septum placement mechanism, the MinCDE system (Min involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*, a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement.

  18. FtsZ Placement in Nucleoid-Free Bacteria

    Science.gov (United States)

    Pazos, Manuel; Casanova, Mercedes; Palacios, Pilar; Margolin, William; Natale, Paolo; Vicente, Miguel

    2014-01-01

    We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO). A second septum placement mechanism, the MinCDE system (Min) involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*), a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement. PMID:24638110

  19. FtsZ placement in nucleoid-free bacteria.

    Science.gov (United States)

    Pazos, Manuel; Casanova, Mercedes; Palacios, Pilar; Margolin, William; Natale, Paolo; Vicente, Miguel

    2014-01-01

    We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO). A second septum placement mechanism, the MinCDE system (Min) involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*), a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement.

  20. Is the efficacy of sacral nerve stimulation for faecal incontinence dependent on the number of active electrode poles achieved during permanent lead insertion?

    Science.gov (United States)

    Duelund-Jakobsen, J; Lundby, L; Lehur, P-A; Wyart, V; Laurberg, S; Buntzen, S

    2016-11-01

    Sacral nerve stimulation (SNS) is effective for faecal incontinence (FI). Little is known about the relationship between the implantation technique and the functional outcome. This study aimed to explore the relationship between the numbers of active electrode poles (AEP) achieved during permanent lead placement and subsequent function, therapeutic amplitude and the need for extra appointments between scheduled follow-up visits. One hundred and eighty-six patients with FI who underwent permanent implantation between May 2009 and March 2015 with a tined (barbed) lead (3093/3080, Medtronic) using the straight stylet were registered on the European two-centre SNS prospective database (SNSPD). Correlation between the number of AEP, function, stimulation amplitude and the need for extra visits was analysed. The numbers of patients having an intra-operative motor response on stimulation of one, two, three and four poles were 18 (9.7%), 75 (40.3%), 61 (32.8%) and 32 (17.2%). The Wexner incontinence score was significantly reduced from 15 (±2.8) at baseline to 9.2 (±4.8) at the latest follow-up after a mean 878 ± 561 days (SD; P  0.05). Patients with four-AEP had a reduced therapeutic amplitude up to 289 (±146) days of follow-up (P < 0.03). The number of AEP did not influence the need for extra follow-up visits (P < 0.223). The functional outcome and number of extra visits after SNS for FI did not depend on the number of AEP achieved. The therapeutic amplitude was reduced during the first postoperative year if four AEP were achieved during lead placement. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  1. Computed Tomographic Evaluation of Bone Stock in Patients With Crowe Type III Developmental Dysplasia of the Hip: Implications for Guiding Acetabular Component Placement Using the High Hip Center Technique.

    Science.gov (United States)

    Liu, Bo; Gao, Yu-Hang; Ding, Lu; Li, Shu-Qiang; Liu, Jian-Guo; Qi, Xin

    2018-03-01

    We evaluated acetabular cup coverage (CC) and rim contact (RC) to evaluate the bone stock above the acetabulum for guiding acetabular component placement using the high hip center technique in patients with Crowe type III developmental dysplasia of the hip. Using hip computed tomography and image processing software, pelvises were reconstructed digitally in 20 hips with Crowe type III developmental dysplasia of the hip. Mimicked cup was placed with anteversion angles of 0° (group I), 5° (group II), and 10° (group III) respectively. In each group, the cup was placed at the anatomical hip center at first, and then the cup was moved up to 40 mm vertically about the native rotation center with an increment of 2.5 mm at each step. CC and RC were calculated and documented with each movement. CC was 65.87%, 67.77%, and 68.98% for group I, group II, and group III at the native rotation center, and increased progressively to 86.45%, 85.85%, and 84.71% at 25 mm above. RC was 49.17%, 50.25%, and 51.92% for group I, group II, and group III at the native rotation center, and increased progressively to 86.87%, 86.39%, and 84.94% at 22.5 mm above. CC and RC were positively correlated, despite the different anteversion angles (r = 0.687 at 0°, 0.683 at 5°, and 0.645 at 10°; P hip center technique in Crowe type III hips. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Holography with a Landau pole

    Science.gov (United States)

    Faedo, Antón F.; Mateos, David; Pantelidou, Christiana; Tarrío, Javier

    2017-02-01

    Holography for UV-incomplete gauge theories is important but poorly understood. A paradigmatic example is d = 4, N=4 super Yang-Mills coupled to N f quark flavors, which possesses a Landau pole at a UV scale ΛLP. The dual gravity solution exhibits a UV singularity at a finite proper distance along the holographic direction. Despite this, holographic renormalization can be fully implemented via analytic continuation to an AdS solution. The presence of a UV cut-off manifests itself in several interesting ways. At energies E ≪ ΛLP no pathologies appear, as expected from effective field theory. In contrast, at scales E ≲ ΛLP the gravitational potential becomes repulsive, and at temperatures T ≲ ΛLP the specific heat becomes negative. Although we focus on N=4 super Yang-Mills with flavor, our qualitative results apply to a much more general class of theories, since they only depend on the fact that the metric near the UV singularity is a hyper-scaling violating metric with exponent θ > d - 1.

  3. Holography with a Landau pole

    Energy Technology Data Exchange (ETDEWEB)

    Faedo, Antón F. [Departament de Física Quántica i Astrofísica and Institut de Ciències del Cosmos (ICC), Universitat de Barcelona, Martí i Franquès 1, ES-08028, Barcelona (Spain); Mateos, David [Departament de Física Quántica i Astrofísica and Institut de Ciències del Cosmos (ICC), Universitat de Barcelona, Martí i Franquès 1, ES-08028, Barcelona (Spain); Institució Catalana de Recerca i Estudis Avançats (ICREA), Passeig Lluís Companys 23, ES-08010, Barcelona (Spain); Pantelidou, Christiana [Departament de Física Quántica i Astrofísica and Institut de Ciències del Cosmos (ICC), Universitat de Barcelona, Martí i Franquès 1, ES-08028, Barcelona (Spain); Tarrío, Javier [Physique Théorique et Mathématique, Université Libre de Bruxelles (ULB), and International Solvay Institutes, Campus de la Plaine CP 231, B-1050, Brussels (Belgium)

    2017-02-08

    Holography for UV-incomplete gauge theories is important but poorly understood. A paradigmatic example is d=4, N=4 super Yang-Mills coupled to N{sub f} quark flavors, which possesses a Landau pole at a UV scale Λ{sub LP}. The dual gravity solution exhibits a UV singularity at a finite proper distance along the holographic direction. Despite this, holographic renormalization can be fully implemented via analytic continuation to an AdS solution. The presence of a UV cut-off manifests itself in several interesting ways. At energies E≪Λ{sub LP} no pathologies appear, as expected from effective field theory. In contrast, at scales E≲Λ{sub LP} the gravitational potential becomes repulsive, and at temperatures T≲Λ{sub LP} the specific heat becomes negative. Although we focus on N=4 super Yang-Mills with flavor, our qualitative results apply to a much more general class of theories, since they only depend on the fact that the metric near the UV singularity is a hyper-scaling violating metric with exponent θ>d−1.

  4. Integrated 3D printing and corona poling process of PVDF piezoelectric films for pressure sensor application

    Science.gov (United States)

    Kim, Hoejin; Torres, Fernando; Wu, Yanyu; Villagran, Dino; Lin, Yirong; Tseng, Tzu-Liang(Bill

    2017-08-01

    This paper presents a novel process to fabricate piezoelectric films from polyvinylidene fluoride (PVDF) polymer using integrated fused deposition modeling (FDM) 3D printing and corona poling technique. Corona poling is one of many effective poling processes that has received attention to activate PVDF as a piezoelectric responsive material. The corona poling process occurs when a PVDF polymer is exposed to a high electric field created and controlled through an electrically charged needle and a grid electrode under heating environment. FDM 3D printing has seen extensive progress in fabricating thermoplastic materials and structures, including PVDF. However, post processing techniques such as poling is needed to align the dipoles in order to gain piezoelectric properties. To further simplify the piezoelectric sensors and structures fabrication process, this paper proposes an integrated 3D printing process with corona poling to fabricate piezoelectric PVDF sensors without post poling process. This proposed process, named ‘Integrated 3D Printing and Corona poling process’ (IPC), uses the 3D printer’s nozzle and heating bed as anode and cathode, respectively, to create poling electric fields in a controlled heating environment. The nozzle travels along the programmed path with fixed distance between nozzle tip and sample’s top surface. Simultaneously, the electric field between the nozzle and bottom heating pad promotes the alignment of dipole moment of PVDF molecular chains. The crystalline phase transformation and output current generated by printed samples under different electric fields in this process were characterized by a Fourier transform infrared spectroscopy and through fatigue load frame. It is demonstrated that piezoelectric PVDF films with enhanced β-phase percentage can be fabricated using the IPC process. In addition, mechanical properties of printed PVDF was investigated by tensile testing. It is expected to expand the use of additive

  5. Tree-loop duality relation beyond single poles

    International Nuclear Information System (INIS)

    Bierenbaum, Isabella; Buchta, Sebastian; Draggiotis, Petros; Malamos, Ioannis; Rodrigo, German

    2012-11-01

    We develop the Tree-Loop Duality Relation for two- and three-loop integrals with multiple identical propagators (multiple poles). This is the extension of the Duality Relation for single poles and multi-loop integrals derived in previous publications. We prove a generalization of the formula for single poles to multiple poles and we develop a strategy for dealing with higher-order pole integrals by reducing them to single pole integrals using Integration By Parts.

  6. Pole-factorization theorem in quantum electrodynamics

    International Nuclear Information System (INIS)

    Stapp, H.P.

    1996-01-01

    In quantum electrodynamics a classical part of the S-matrix is normally factored out in order to obtain a quantum remainder that can be treated perturbatively without the occurrence of infrared divergences. However, this separation, as usually performed, introduces spurious large-distance effects that produce an apparent breakdown of the important correspondence between stable particles and poles of the S-matrix, and, consequently, lead to apparent violations of the correspondence principle and to incorrect results for computations in the mesoscopic domain lying between the atomic and classical regimes. An improved computational technique is described that allows valid results to be obtained in this domain, and that leads, for the quantum remainder, in the cases studied, to a physical-region singularity structure that, as regards the most singular parts, is the same as the normal physical-region analytic structure in theories in which all particles have non-zero mass. The key innovations are to define the classical part in coordinate space, rather than in momentum space, and to define there a separation of the photon-electron coupling into its classical and quantum parts that has the following properties: (1) The contributions from the terms containing only classical couplings can be summed to all orders to give a unitary operator that generates the coherent state that corresponds to the appropriate classical process, and (2) The quantum remainder can be rigorously shown to exhibit, as regards its most singular parts, the normal analytic structure. (orig.)

  7. A Comparative Analysis of the New Five-Pole and Three-Pole Active Magnet Bearing

    Directory of Open Access Journals (Sweden)

    Pedram Vakili

    2012-07-01

    Full Text Available In recent years, more attention has been given to the active AMBs thanks to their low maintenance cost, suitability for clean environments, and high speed. One of the popular types of AMBs is the three-pole type with integrated and separate cores. Some deficiencies of this type of bearing are its high oscillation, low stability and low efficiency. This paper seeks to analyse the three-pole AMBs and describe their deficiencies and introduce and analyse a new five-pole AMB. The model thus proposed has lower oscillation as well as more stability and efficiency. The five-pole AMB has been simulated by a controller in the presence of disturbance. The results of simulation demonstrate lower vibration and oscillation in the five-pole AMB in comparison with the three-pole model.

  8. On pole structure assignment in linear systems

    Czech Academy of Sciences Publication Activity Database

    Loiseau, J.-J.; Zagalak, Petr

    2009-01-01

    Roč. 82, č. 7 (2009), s. 1179-1192 ISSN 0020-7179 R&D Projects: GA ČR(CZ) GA102/07/1596 Institutional research plan: CEZ:AV0Z10750506 Keywords : linear systems * linear state feedback * pole structure assignment Subject RIV: BC - Control Systems Theory Impact factor: 1.124, year: 2009 http://library.utia.cas.cz/separaty/2009/AS/zagalak-on pole structure assignment in linear systems.pdf

  9. Clouds Over the North Pole

    Science.gov (United States)

    2004-01-01

    [figure removed for brevity, see original site] Released 29 June 2004 The atmosphere of Mars is a dynamic system. Water-ice clouds, fog, and hazes can make imaging the surface from space difficult. Dust storms can grow from local disturbances to global sizes, through which imaging is impossible. Seasonal temperature changes are the usual drivers in cloud and dust storm development and growth. Eons of atmospheric dust storm activity has left its mark on the surface of Mars. Dust carried aloft by the wind has settled out on every available surface; sand dunes have been created and moved by centuries of wind; and the effect of continual sand-blasting has modified many regions of Mars, creating yardangs and other unusual surface forms. Like yesterday's image, the linear 'ripples' are water-ice clouds. As spring is deepening at the North Pole these clouds are becoming more prevalent. Image information: VIS instrument. Latitude 68.9, Longitude 135.5 East (224.5 West). 38 meter/pixel resolution. Note: this THEMIS visual image has not been radiometrically nor geometrically calibrated for this preliminary release. An empirical correction has been performed to remove instrumental effects. A linear shift has been applied in the cross-track and down-track direction to approximate spacecraft and planetary motion. Fully calibrated and geometrically projected images will be released through the Planetary Data System in accordance with Project policies at a later time. NASA's Jet Propulsion Laboratory manages the 2001 Mars Odyssey mission for NASA's Office of Space Science, Washington, D.C. The Thermal Emission Imaging System (THEMIS) was developed by Arizona State University, Tempe, in collaboration with Raytheon Santa Barbara Remote Sensing. The THEMIS investigation is led by Dr. Philip Christensen at Arizona State University. Lockheed Martin Astronautics, Denver, is the prime contractor for the Odyssey project, and developed and built the orbiter. Mission operations are

  10. The potential of wood-based composite poles

    Science.gov (United States)

    Todd F. Shupe; Cheng Piao; Chung Y. Hse

    2009-01-01

    Wood-based composite utility poles are receiving increasing attention in the North American pole market. This interest is being driven by many increasing factors such as increasing: (1) disposal costs of solid wood poles, (2) liability and environmental concerns with traditional means of disposal of solid wood poles, (3) cost and concerns of long-term...

  11. Mechanical properties of small-scale wood laminated composite poles

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; Chung Y. Hse

    2004-01-01

    Power companies in the United States consume millions of solid wood poles every year. These poles are from high-valued trees that are becoming more expensive and less available. wood laminated composite poles (LCP) are a novel alternative to solid wood poles. LCP consists of trapezoid wood strips that are bonded by a synthetic resin. The wood strips can be made from...

  12. 2D Stabilised analytic signal method in DC pole-pole potential data ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Using analytic signal method, interpretation of pole-pole secondary electric potentials due to 2D conductive/resistive prisms is presented. ... residual separation to separate out residual anom- alies, which are interpreted for geological .... terms, which are used for the semi-quantitative interpretation. 6.1 Computation of ...

  13. An unusual complication of ischemic injury to upper pole ureter during lower pole heminephroureterectomy

    Directory of Open Access Journals (Sweden)

    Katherine Victoria Hurst

    2013-01-01

    Full Text Available Lower pole heminephroureterectomy is a common paediatric urology procedure with few reported complications. We report a case of possible vascular ischemic injury to the normal remaining ureter following a lower pole heminephroureterectomy, probably due to both ureters sharing a common blood supply. Extra caution in such procedures is therefore warranted.

  14. Jupiter's interior and deep atmosphere: The initial pole-to-pole passes with the Juno spacecraft

    DEFF Research Database (Denmark)

    Bolton, S. J.; Adriani, Alberto; Adumitroaie, V.

    2017-01-01

    On 27 August 2016, the Juno spacecraft acquired science observations of Jupiter, passing less than 5000 kilometers above the equatorial cloud tops. Images of Jupiter's poles show a chaotic scene, unlike Saturn's poles. Microwave sounding reveals weather features at pressures deeper than 100 bars,...

  15. 2D Stabilised analytic signal method in DC pole-pole potential data ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Using analytic signal method, interpretation of pole-pole secondary electric potentials due to 2D conductive/resistive prisms is presented. The estimated parameters are the location, lateral extent or width and depth to top surface of the prism. Forward modelling is attempted by 2D-Finite. Difference method. The proposed ...

  16. VLSI Cells Placement Using the Neural Networks

    International Nuclear Information System (INIS)

    Azizi, Hacene; Zouaoui, Lamri; Mokhnache, Salah

    2008-01-01

    The artificial neural networks have been studied for several years. Their effectiveness makes it possible to expect high performances. The privileged fields of these techniques remain the recognition and classification. Various applications of optimization are also studied under the angle of the artificial neural networks. They make it possible to apply distributed heuristic algorithms. In this article, a solution to placement problem of the various cells at the time of the realization of an integrated circuit is proposed by using the KOHONEN network

  17. Pole-zero form fractional model identification in frequency domain

    International Nuclear Information System (INIS)

    Mansouri, R.; Djamah, T.; Djennoune, S.; Bettayeb, M.

    2009-01-01

    This paper deals with system identification in the frequency domain using non integer order models given in the pole-zero form. The usual identification techniques cannot be used in this case because of the non integer orders of differentiation which makes the problem strongly nonlinear. A general identification method based on Levenberg-Marquardt algorithm is developed and allows to estimate the (2n+2m+1) parameters of the model. Its application to identify the ''skin effect'' of a squirrel cage induction machine modeling is then presented.

  18. New magnet pole shape for isochronous cyclotrons

    International Nuclear Information System (INIS)

    Thorn, C.E.; Chasman, C.; Baltz, A.J.

    1981-01-01

    A new design has been developed for shaping pole tips to produce the radially increasing fields required for isochronous cyclotrons. The conventional solid hill poles are replaced by poles mounted over a small secondary gap which tapers radially from maximum at the magnet edge to zero near the center. Field measurements with a model magnet and calculations with the code TRIM show an increase in field at the edge of the magnet without the usual corresponding large increase in fringing, and a radial field shape more nearly field independent than for conventional hills. The flying hills have several advantages for variable energy multiparticle cyclotrons: (1) a large reduction in the power dissipated by isochronizing trim coils; (2) a more constant shape and magnitude flutter factor, eliminating flutter coils and increasing the operating range; and (3) a sharper fall-off of the fringe field, simplifying beam extraction

  19. Pole solutions for flame front propagation

    CERN Document Server

    Kupervasser, Oleg

    2015-01-01

    This book deals with solving mathematically the unsteady flame propagation equations. New original mathematical methods for solving complex non-linear equations and investigating their properties are presented. Pole solutions for flame front propagation are developed. Premixed flames and filtration combustion have remarkable properties: the complex nonlinear integro-differential equations for these problems have exact analytical solutions described by the motion of poles in a complex plane. Instead of complex equations, a finite set of ordinary differential equations is applied. These solutions help to investigate analytically and numerically properties of the flame front propagation equations.

  20. Fundamental pole parameters of the N(1470)

    CERN Document Server

    Lee, P S

    1973-01-01

    The position and residue of the S-matrix pole of the Delta (1236) have been shown to be unique and independent of the particular resonance formula used, thus resolving a discrepancy among phenomenological fits. Unlike the P/sub 33/ partial wave, the P/sub 11/ resonance is highly inelastic, very broad, and has a large background. This produces huge uncertainties in its mass and width, depending on the parametrization used. It is reported that the position of the N(1470) pole is uniquely determined, 1380-110i MeV, from fits to the CERN phase shifts. (10 refs).

  1. Rotor pole refurbishment for hydrogenerators: insulation problems and solutions

    International Nuclear Information System (INIS)

    Reynolds, R.R.; Rux, L.

    2005-01-01

    Rotor poles for Unit 1 at Lower Granite Powerhouse were removed from the rotor and shipped to a repair facility for refurbishment. Upon inspection, it was found that all of the pole bodies exhibited a distinct bow, center to end, on the pole mounting surface. In some cases, the deflection was as much as 0.106 inch. Concerns were raised about how this condition might affect the ability to properly insulate and/or re-seat the poles. This paper presents details of the rotor pole and field winding evaluation, the problems encountered, and the solutions implemented to successfully refurbish the rotor poles and field winding. (author)

  2. Recent advances in poled optical fibres

    DEFF Research Database (Denmark)

    Pruneri, V.; Margulis, W.; Myrén, N.

    2005-01-01

    A second-order nonlinearity can be induced in optical fibres through poling. We describe accomplishments of the EU project GLAMOROUS in making low-cost high performance electrooptic and nonlinear optical fibre- and waveguide-based components. In particular a comparison with more traditional...

  3. Quasiparticle pole strength in nuclear matter

    International Nuclear Information System (INIS)

    Poggioli, R.S.; Jackson, A.D.

    1975-01-01

    It is argued that single-particle-like behavior in nuclear matter is much less probable than Brueckner theory suggests. In particular, the quasiparticle pole strength is evaluated for nuclear matter and it is shown that, contrary to the spirit of Brueckner theory, low momentum states play a crucial role in determining the magnitude of z/sub k/sub F/. (auth)

  4. Kosovo : kannatlikkusele lootmine pole plaan / Chris Patten

    Index Scriptorium Estoniae

    Patten, Chris

    2007-01-01

    Autor leiab, et arvestades Kosovo elanike ülekaalukat soovi olla vaba Serbiast, riigist, mis üritas nad kõrvaldada, ning alternatiivi täielikku puudumist Belgradi poolt, pole rahvusvahelisel kogukonnal muud võimalust kui anda Kosovole iseseisvus

  5. Pole masses of quarks in dimensional reduction

    International Nuclear Information System (INIS)

    Avdeev, L.V.; Kalmykov, M.Yu.

    1997-01-01

    Pole masses of quarks in quantum chromodynamics are calculated to the two-loop order in the framework of the regularization by dimensional reduction. For the diagram with a light quark loop, the non-Euclidean asymptotic expansion is constructed with the external momentum on the mass shell of a heavy quark

  6. The effects of poling on physiological, kinematic and kinetic responses in roller ski skating.

    Science.gov (United States)

    Grasaas, Erik; Hegge, Ann Magdalen; Ettema, Gertjan; Sandbakk, Øyvind

    2014-09-01

    We investigated the effects of poling on physiological, kinematic and kinetic responses in the G4 skating technique where the poling movement is synchronized with the leg push-off on one side (strong side) followed by a forward arm swing during the leg push-off on the other side (weak side). G4 skating with (G4-P) and without (G4-NP) poling was compared in 17 elite male cross-country skiers during 4-min submaximal tests on a 2% inclined roller ski treadmill at 10, 15 and 20 km h(-1). G4-P demonstrated less ventilatory stress and higher gross efficiency compared to G4-NP at all velocities, and the blood lactate concentration was lower at the high velocity (all P ski forces, increased ski velocities and less angling and edging of the skis (all P ski forces on the strong side were lower than on the weak side with G4-P at all velocities (all P ski forces at a given work rate with G4-P demonstrate the effectiveness of poling in the G4 skating technique. Thus, poling provides possibilities to increase total propulsion, to reduce ski forces and to enhance skiing efficiency.

  7. Third Pole Environment (TPE) -Latest Progress

    Science.gov (United States)

    Liu, Z.; Yao, T.; Zhang, F.; Yang, X.; Wang, W.; Ping, F.

    2014-12-01

    Centered on the Tibetan Plateau, the Third Pole region is a unique geographical unit, which represents one of the largest ice masses on the Earth. The region has great impacts on environmental changes in China, the Northern Hemisphere and the globe.It also demonstrates sensitive feedbacks to global changes and the impacts of anthropogenic activities in surrounding regions. Like the Arctic and Antarctica, the Third Pole region is an especially sensitive area that draws great attention from the scientific community. In 2009, with support from the Chinese Academy of Sciences and international organizations, the Third Pole Environment (TPE) program, led by Chinese scientists, was officially launched. The program focuses on the theme of "water-ice-air-ecosystem-human" interactions, with the aim to address the following scientific questions, such as the spatial and temporal characteristics of past environmental changes in the Third pole, the interactions between hydrosphere and cryosphere and hazard processes, the ecological systems' impacts on and response to environmental changes, and the impacts of anthropogenic activities on environmental changes in the region and adaptation strategies. The goal of the program is to reveal environmental change processes and mechanisms on the Third Pole and their influences on and responses to global changes, and thus to serve for enhancement of human adaptation to the changing environment and realization of human-nature harmony. Under the leadership of the co-chairs, and relying on Scientific Committee and the TPE office, the program has accomplished a number of scientific tasks since its inauguration. TPE has made tremendous progress in the research of glacier changes, interactions between the westerlies and monsoon, establishment of field stations, data sharing and education.

  8. Fatigue failure and cracking in high mast poles.

    Science.gov (United States)

    2012-03-01

    This report presents the findings of a comprehensive research project to investigate the fatigue : cracking and failure of galvanized high mast illumination poles (HMIP). Ultrasonic inspection of : poles throughout the state has revealed the presence...

  9. Laparoscopic upper pole heminephroureterectomy in children: Seven-year experience

    Directory of Open Access Journals (Sweden)

    Antonio Marte

    2015-01-01

    Full Text Available Background: Minimally invasive surgery is the current approach to perform heminephroureterectomy (HN in children. This can be obtained through a transperitoneal (TP or a retroperitoneal approach. Here, we report our experience using a TP approach. Materials and Methods: From 2005 to 2014, 22 TP laparoscopic upper poles HN were performed at our institution. There were nine girls and 13 boys aged between 20 months and 6 years (mean age 3.9. Eight patients were diagnosed prenatally, 17 patients presented with urinary tract infection (UTI and three with vomiting and failure to thrive. The indication for HN was reflux nephropathy and UTI in non-functioning upper pole in 19 patients and cystic dysplasia in 1 patient. The surgical technique involved the following steps: Cystoscopic recognition; positioning of 3-4 trocar (right HN; identification of the kidney (detachment of the colon; isolation and low ligation of the dilated ureter; decrossing from renal vessels; section of the parenchyma by LigaSure; haemostasis with clips and LigaSure; drain. Results: The mean operative time was 154 min (range: 81-220 min. All patients were discharged from the 2 nd to 4 th day. Neither major complication nor conversion was recorded. 1 patient presented leakage of urine for 7 days from the drainage which resolved spontaneously. At ultrasound follow-up, 5 patients showed a secondary perirenal cyst, 2-5 cm diameter that resolved spontaneously. Conclusion: The results indicate that laparoscopic upper pole heminephrectomy is the treatment of choice in cases of non-functioning dilated lower segments of duplicated kidneys. The use of laparoscopic approach offers a good working space, a good visual control of the vessels and allows a very low isolation of the ureteral stump which counterbalance the peritoneal violation.

  10. An adaptive single pole autoreclosure based on zero sequence power

    Energy Technology Data Exchange (ETDEWEB)

    Elkalashy, Nagy I.; Darwish, Hatem A.; Taalab, Abdel-Maksoud I.; Izzularab, Mohmmad A. [Electrical Engineering Department, Faculty of Engineering, Menoufiya University, Shebin Elkom 32511 (Egypt)

    2007-04-15

    In this paper, a novel adaptive single pole autoreclosure is introduced. This reclosure is based on monitoring the fundamental component of the zero sequence instantaneous power to detect the extinction instant of the arc in its secondary period. Thus, adaptive closing instant can be achieved. The concept of reclosure is validated via typical examples of transmission line exposed to ground arcing fault. Effects of fault location and load flow on the accuracy of the technique are examined. Discriminatory zones of the secondary arc period in the zero sequence power domains are determined. A proposed threshold for the reclosing instant is introduced and examined. Validation of the proposed algorithm is verified via Digital Signal Processing (DSP) experimental test set-up. The test results corroborate the efficacy of proposed technique. (author)

  11. Minimal guided bone regeneration procedure for immediate implant placement in the esthetic zone

    Directory of Open Access Journals (Sweden)

    Nettemu Sunil Kumar

    2013-01-01

    Full Text Available The anterior maxilla presents a challenging milieu interior for ideal placement of implants because of the compromised bone quality. With the advent of intraoral bone harvesting and augmentation techniques, immediate implant placement into fresh extraction sockets have become more predictable. Immediate implant placement has numerous advantages compared to the delayed procedure including superior esthetic and functional outcomes, maintenance of soft and hard tissue integrity and increased patient compliance. This case report exhibits immediate implant placement in the maxillary esthetic zone by combining a minimal invasive autogenous block bone graft harvest technique for ensuring successful osseointegration of the implant at the extraction site.

  12. Influence of the density pole on the performances of its gamma ...

    African Journals Online (AJOL)

    In this paper, we aim at highlighting the in uence of the density pole on the performances of its gamma-kernel estimator. To do this, we performed a comparative study for the performances of the gamma-kernel estimators with those provided by other bias effect correction techniques at the bounds, using the simulation ...

  13. Research of Tan{delta} Measurement of Pole Transformers using DSP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Chul; Lee, Bo Ho [Soong Sil University (Korea, Republic of); Kim, Oun Seok [Korea Electrotechnology Research Institute (Korea, Republic of); Choi, Do Hyuk [Korea Institute of Construction Technology (Korea, Republic of); Lee, Su Kil [Korea Railroad Research Institute (Korea, Republic of)

    1997-04-30

    This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformers by using digital signal processor. After applying voltage to the condenser which is installed in a transformer, acquiring source voltage and current of condenser and using cross-correlation techniques, we can check the dissipation factor of insulation oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross-correlation techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with Schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers. (author). 7 refs., 11 figs., 1 tab.

  14. Economics of Red Pine Management for Utility Pole Timber

    Science.gov (United States)

    Gerald H. Grossman; Karen Potter-Witter

    1991-01-01

    Including utility poles in red pine management regimes leads to distinctly different management recommendations. Where utility pole markets exist, managing for poles will maximize net returns. To do so, plantations should be maintained above 110 ft2/ac, higher than usually recommended. In Michigan's northern lower peninsula, approximately...

  15. Theoretical modeling and experimental analyses of laminated wood composite poles

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; Vijaya Gopu; Chung Y. Hse

    2005-01-01

    Wood laminated composite poles consist of trapezoid-shaped wood strips bonded with synthetic resin. The thick-walled hollow poles had adequate strength and stiffness properties and were a promising substitute for solid wood poles. It was necessary to develop theoretical models to facilitate the manufacture and future installation and maintenance of this novel...

  16. 46 CFR 111.79-3 - Grounding pole.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Grounding pole. 111.79-3 Section 111.79-3 Shipping COAST... REQUIREMENTS Receptacles § 111.79-3 Grounding pole. Each receptacle outlet that operates at 100 volts or more must have a grounding pole. ...

  17. Clusters of cyclones encircling Jupiter's poles.

    Science.gov (United States)

    Adriani, A; Mura, A; Orton, G; Hansen, C; Altieri, F; Moriconi, M L; Rogers, J; Eichstädt, G; Momary, T; Ingersoll, A P; Filacchione, G; Sindoni, G; Tabataba-Vakili, F; Dinelli, B M; Fabiano, F; Bolton, S J; Connerney, J E P; Atreya, S K; Lunine, J I; Tosi, F; Migliorini, A; Grassi, D; Piccioni, G; Noschese, R; Cicchetti, A; Plainaki, C; Olivieri, A; O'Neill, M E; Turrini, D; Stefani, S; Sordini, R; Amoroso, M

    2018-03-07

    The familiar axisymmetric zones and belts that characterize Jupiter's weather system at lower latitudes give way to pervasive cyclonic activity at higher latitudes. Two-dimensional turbulence in combination with the Coriolis β-effect (that is, the large meridionally varying Coriolis force on the giant planets of the Solar System) produces alternating zonal flows. The zonal flows weaken with rising latitude so that a transition between equatorial jets and polar turbulence on Jupiter can occur. Simulations with shallow-water models of giant planets support this transition by producing both alternating flows near the equator and circumpolar cyclones near the poles. Jovian polar regions are not visible from Earth owing to Jupiter's low axial tilt, and were poorly characterized by previous missions because the trajectories of these missions did not venture far from Jupiter's equatorial plane. Here we report that visible and infrared images obtained from above each pole by the Juno spacecraft during its first five orbits reveal persistent polygonal patterns of large cyclones. In the north, eight circumpolar cyclones are observed about a single polar cyclone; in the south, one polar cyclone is encircled by five circumpolar cyclones. Cyclonic circulation is established via time-lapse imagery obtained over intervals ranging from 20 minutes to 4 hours. Although migration of cyclones towards the pole might be expected as a consequence of the Coriolis β-effect, by which cyclonic vortices naturally drift towards the rotational pole, the configuration of the cyclones is without precedent on other planets (including Saturn's polar hexagonal features). The manner in which the cyclones persist without merging and the process by which they evolve to their current configuration are unknown.

  18. Elemental Mercury Diffusion Processes and Concentration at the Lunar Poles

    Science.gov (United States)

    Moxley, Frederick; Killen, Rosemary M.; Hurley, Dana M.

    2011-01-01

    In 2009, the Lyman Alpha Mapping Project (LAMP) spectrograph onboard the Lunar Reconnaissance Orbiter (LRO) spacecraft made the first detection of element mercury (Hg) vapor in the lunar exosphere after the Lunar Crater Observing and Sensing Satellite (LCROSS) Centaur rocket impacted into the Cabeus crater in the southern polar region of the Moon. The lunar regolith core samples from the Apollo missions determined that Hg had a devolatilized pattern with a concentration gradient increasing with depth, in addition to a layered pattern suggesting multiple episodes of burial and volatile loss. Hg migration on the lunar surface resulted in cold trapping at the poles. We have modeled the rate at which indigenous Hg is lost from the regolith through diffusion out of lunar grains. We secondly modeled the migration of Hg vapor in the exosphere and estimated the rate of cold-trapping at the poles using a Monte Carlo technique. The Hg vapor may be lost from the exosphere via ionization, Jeans escape, or re-impact into the surface causing reabsorption.

  19. Comparison of esophageal placement of Bravo capsule system under direct endoscopic guidance with conventional placement method

    Directory of Open Access Journals (Sweden)

    Aijaz A Sofi

    2010-10-01

    Full Text Available Aijaz A Sofi, Charles Filipiak, Thomas Sodeman, Usman Ahmad, Ali Nawras, Isam DaboulDepartment of Medicine, Division of Gastroenterology, University of Toledo Medical Center, Toledo, Ohio, USABackground: Conventional placement of a wireless esophageal pH monitoring device in the esophagus requires initial endoscopy to determine the distance to the gastroesophageal junction. Blind placement of the capsule by the Bravo delivery system is followed by repeat endoscopy to confirm placement. Alternatively, the capsule can be placed under direct vision during endoscopy. Currently there are no published data comparing the efficiency of one method over the other. The objective of this study was to compare the method of Bravo wireless pH deviceplacement under direct visualization with the conventional method.Methods: A retrospective study involving 58 patients (29 patients with indirect and 29 patients with direct visualization who had Bravo capsule placement. The physician endoscopy procedure notes, nurse’s notes, postprocedure notes, recovery notes, and pH monitoring results were reviewed. The safety of the procedures, length of the procedures, and patient tolerability were evaluated.Results: None of the 58 patients had early detachment of the device and had no immediate procedure-related complications. The overall incidence of complications in both the groups was similar. No failures due to the technique were noted in either group. Average amount of time taken for the procedure was similar in both groups.Conclusion: The technique of placing a Bravo pH device under direct visualization is as safe and effective as the conventional method. In addition, there is an added advantage of avoiding a second endoscopic intubation in the direct visualization technique.Keywords: Bravo capsule, technique, esophageal pH monitoring

  20. The Gattini South Pole UV experiment

    Science.gov (United States)

    Moore, Anna M.; Ahmed, Sara; Ashley, Michael C. B.; Croner, Ernest; Delacroix, Alex; Ebihara, Yusuke; Fucik, Jason; Martin, D. Christopher; Velur, Viswa; Weatherwax, Allan

    2012-09-01

    The Gattini South Pole UV experiment (Gattini SPUV) was deployed to the South Pole dark sector in February 2010 and has recently completed a highly successful first season of winter time observations. The experiment has, for the first time ever, measured and categorized the optical night sky brightness at the very blue wavelengths. The experiment consists of a remotely operated 6” aperture custom designed telescope. The telescope feeds a blue sensitive imager with 4 degree field of view that contains a bank of 3 filters: SDSS g’, Bessel U and a custom “super U” filter specifically designed to probe the sky emission at wavelengths approaching the atmospheric cut-off. The filters are continually cycled with exposure times ranging from 30 to 300 seconds throughout the winter period. The telescope, in addition, feeds a 2 degree long slit VPH grating spectrograph with R~1000. The bandwidth is 350-450nm. The spectra are recorded simultaneously with the imager exposures. The experiment is designed for low temperature Antarctic operation and resides on the roof of the MAPO building in the South Pole Antarctic sector. The primary science goals are to categorize the Antarctic winter-time sky background at the very bluest of wavelengths as a pathfinder for the Antarctic Cosmic Web Imager. We present a technical overview of the experiment and results from the first winter season.

  1. The South Pole and the Ross Sea

    Science.gov (United States)

    2002-01-01

    This image shows a rare clear view of the South Pole (lower right) and the Ross Sea, Antarctica. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) acquired the scene on December 26, 2001. The geographic South Pole is located in the center of Antarctica, at an altitude of 2,900 meters (9,300 feet). It rests on a continent-wide ice sheet that is 2,870 m thick, with the underlying bedrock only 30 m (98 feet) above sea level. The ice underlying the South Pole is as much as 140,000 years old, and is currently accumulating at about 82 cm (32 inches) per year. Roughly 2,500 km (1,550 miles) away is the green water of the Ross Sea, which indicates the presence of large numbers of phytoplankton. This is a highly productive part of the world's oceans. Also note the ice gathered around McMurdo Sound, seen toward the lefthand shoreline of the Ross Sea, at the edge of the Ross Ice Shelf. According to National Science Foundation researchers, this ice is making it difficult for penguins to reach their food supply. Separating the continental Antarctic ice sheet from the Ross Sea are the Queen Maud Mountains and the Ross Ice Shelf. Image courtesy the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  2. Crystalline texture study of Zr-2.5%Nb pressure pipes by DRX pole figures

    International Nuclear Information System (INIS)

    Buioli, C P; Banchik, A D; Vizcaino, P; Samper, R; Testone, S

    2012-01-01

    This work presents the study of crystalline texture of Zr-2.5%Nb pressure tubes (A, B and C); structural components of CANDU nuclear power reactors [1]. The study of texture was made using the RX diffraction technique, making measurements of direct pole figures [2], in a Phillips diffractometer with pole goniometer (IFIR-CONICET). The texture was determined calculating the coefficients of JJ Kearns [3]. The samples used correspond to transversal sections of the tubes, front and back, and were characterized making de measurements of five pole figures with Miller index (001), (100), (101), (102) and (110), in order to represent in a complete way the texture in the material. The calculated Kearns coefficients were compared with the specifications given by the designer of pressure tubes AECL [4] (author)

  3. Determination of the dominant resonance pole of the three-neutron system

    International Nuclear Information System (INIS)

    Moeller, K.

    1981-03-01

    The resonance behaviour of a system of three neutrons interacting via s-wave separable Yamaguchi potential is considered. For the quantum numbers (T,S,Lsup(π)) = (3/2, 1/2, 1 - ) the dominating pole of the S-matrix is determined by applying contour deformation technique to solve the homogeneous Faddeev equation on the nonphysical sheets of the S-matrix. For the positions and the asymptotic normalization constant of the dominating pole pair the values z 3 = (-88.0 +- i 27.9) keV and Csub(p) 2 = -0.05 +- i 0.1 are obtained. Although the pole pair is close to the real axis in the complex energy plane it is not expected to cause an observable experimental effect due to the smallness of the asymptotic normalization constant. (author)

  4. Impact of Brand Placements in Bollywood Movies – Researching The Youth

    OpenAIRE

    Narula, Divya

    2009-01-01

    This research explores how brand placement in Bollywood movies is perceived by the viewers and to what extent are they affected by these placements. Brand Placements in the Bollywood industry has grown rapidly over the last few years. In this age of global advertising, marketers are looking for new techniques of advertising to promote their brands to a larger audience. This research comprises of the views of Indian students in New Delhi and NCR. This paper will review the literature on brand ...

  5. Eight piece quadrupole magnet, method for aligning quadrupole magent pole tips

    Energy Technology Data Exchange (ETDEWEB)

    Jaski, Mark S.; Liu, Jie; Donnelly, Aric T.; Downey, Joshua S.; Nudell, Jeremy J.; Jain, Animesh

    2018-01-30

    The invention provides an alternative to the standard 2-piece or 4-piece quadrupole. For example, an 8-piece and a 10-piece quadrupole are provided whereby the tips of each pole may be adjustable. Also provided is a method for producing a quadrupole using standard machining techniques but which results in a final tolerance accuracy of the resulting construct which is better than that obtained using standard machining techniques.

  6. Performance of claw-poled PM-stepping motor

    International Nuclear Information System (INIS)

    Liu, C.P.; Jeng, G.R.; Chen, W.C.; Tsai, M.C.; Wu, K.T.; Yao, Y.D.

    2007-01-01

    Present work is to analyze the performance of a permanent-magnetic (PM) stepping motor with claw poles by using the magnetic-circuit simulation technique. In this paper, we calculate the torque characteristics of the motor, such as the detent and the holding torques, and the step-position error by changing the gap between the upper and the lower stators and the staggered angle between the two stators. Through comparison of numerical data with experiment measurements, we found that the detent torque could be effectively reduced by increasing the stator-to-stator gap and further by decreasing the step-position error. Furthermore, the holding torque could be unchanged as the stator assemblage changed; however, it would be degenerated under the condition of low magnetization

  7. Laryngeal mask placement in a teaching institution: analysis of difficult placements [version 1; referees: 2 approved, 1 approved with reservations

    Directory of Open Access Journals (Sweden)

    Anastasia D Katsiampoura

    2015-04-01

    Full Text Available Background: Laryngeal mask airway (LMA placement is now considered a common airway management practice. Although there are many studies which focus on various airway techniques, research regarding difficult LMA placement is limited, particularly for anesthesiologist trainees. In our retrospective analysis we tried to identify predictive factors of difficult LMA placement in an academic training program. Methods: This retrospective analysis was derived from a research airway database, where data were collected prospectively at the Memorial Hermann Hospital, Texas Medical Center, Houston, TX, USA, from 2008 to 2010. All non-obstetric adult patients presenting for elective surgery requiring general anesthesia, were enrolled in this study: anesthesiology residents primarily managed the airways. The level of difficulty, number of attempts, and type of the extraglottic device placement were retrieved. Results: Sixty-nine unique Laryngeal Mask Airways (uLMAs were utilized as a primary airway device. Two independent predictors for difficult LMA placement were identified: gender and neck circumference. The sensitivity for one factor is 87.5% with a specificity of 50%. However with two risk factors, the specificity increases to the level of 93% and the sensitivity is 63%. Conclusion: In a large academic training program, besides uLMA not been used routinely, two risk factors for LMA difficulty were identified, female gender and large neck circumference. Neck circumference is increasingly being recognized as a significant predictor across the spectrum of airway management difficulties while female gender has not been previously reported as a risk factor for difficult LMA placement.

  8. Ultrasound-guided central venous catheter placement : a structured review and recommendations for clinical practice

    NARCIS (Netherlands)

    Saugel, Bernd; Scheeren, Thomas W L; Teboul, Jean-Louis

    2017-01-01

    The use of ultrasound (US) has been proposed to reduce the number of complications and to increase the safety and quality of central venous catheter (CVC) placement. In this review, we describe the rationale for the use of US during CVC placement, the basic principles of this technique, and the

  9. K.S. micro-implant placement guide | Sharma | Annals of Medical ...

    African Journals Online (AJOL)

    A one of the greatest concerns with orthodontic mini-implants is risk of injury to dental roots during placement is, especially when they are inserted between teeth. Many techniques have been used to facilitate safe placement of interradicular miniscrews. Brass Wires or metallic markers are easy to place in the interproximal ...

  10. Voltage regulator placement in radial distribution system using plant ...

    African Journals Online (AJOL)

    The VR problem consists of two sub problems, that of optimal placement and optimal choice of tap setting. The proposed method deals with initial selection of voltage regulator buses by using power loss indices (PLI). The candidate node identification technique and Plant Growth Simulation Algorithm (PGSA) are used for ...

  11. Self-expanding metal stent placement for oesophageal cancer ...

    African Journals Online (AJOL)

    This article documents the technique and periprocedural experience. Patients and methods. All patients who had SEMS placement for ... Repeat stenting was for stent migration (n=15), tumour overgrowth (n=26) and a blocked stent and a stricture (n=1 each). Complications were recorded in six cases (1.3%): iatrogenic TOF ...

  12. MVMO-based approach for optimal placement and tuning of ...

    African Journals Online (AJOL)

    ... optimal placement and coordinated tuning of power system supplementary damping controllers (POCDCs). The effectiveness of the approach is evaluated based on the classical IEEE 39-bus (New England) test system. Numerical results include performance comparisons with other metaheuristic optimization techniques, ...

  13. Optimal placement of distributed generation in distribution networks ...

    African Journals Online (AJOL)

    This paper proposes the application of Particle Swarm Optimization (PSO) technique to find the optimal size and optimum location for the placement of DG in the radial distribution networks for active power compensation by reduction in real power losses and enhancement in voltage profile. In the first segment, the optimal ...

  14. Secondary electron emission yield on poled silica based thick films

    DEFF Research Database (Denmark)

    Braga, D.; Poumellec, B.; Cannas, V.

    2004-01-01

    injection, we pointed out an electric field 0.5 µm below the surface for our poling conditions and directed in the same direction as the external field applied during the poling process. Then, the dependence of on the injected dose of electrons allows us to deduce that the poling process disturbs the glass......Studies on the distribution of the electric field produced by a thermal poling process in a layer of Ge-doped silica on silicon substrate, by using secondary electron emission yield (SEEY) measurements () are presented. Comparing 0 between poled and unpoled areas, the SEEY at the origin of electron...... structure strongly enough for leading to a weak conductivity. It is then easy to display the poled areas. We have also pointed out an effect of the electric properties of the glass on the measurements obtained with the Electron Probe for MicroAnalysis....

  15. Neuroendoscopic stent placement for cerebrospinal fluid pathway obstructions in adults.

    Science.gov (United States)

    Marx, Sascha; Fleck, Steffen K; El Refaee, Ehab; Manwaring, Jotham; Vorbau, Christina; Fritsch, Michael J; Gaab, Michael R; Schroeder, Henry W S; Baldauf, Joerg

    2016-09-01

    OBJECTIVE Since its revival in the early 1990s, neuroendoscopy has become an integral component of modern neurosurgery. Endoscopic stent placement for treatment of CSF pathway obstruction is a rarely used and underestimated procedure. The authors present the first series of neuroendoscopic intracranial stenting for CSF pathway obstruction in adults with associated results and complications spanning a long-term follow-up of 20 years. METHODS The authors retrospectively reviewed a prospectively maintained clinical database for endoscopic stent placement performed in adults between 1993 and 2013. RESULTS Of 526 endoscopic intraventricular procedures, stents were placed for treatment of CSF disorders in 25 cases (4.8%). The technique was used in the management of arachnoid cysts (ACs; n = 8), tumor-related CSF disorders (n = 13), and hydrocephalus due to stenosis of the foramen of Monro (n = 2) or aqueduct (n = 2). The mean follow-up was 87.1 months. No deaths or infections occurred that were related to endoscopic placement of intracranial stents. Late stent dislocation or migration was observed in 3 patients (12%). CONCLUSIONS Endoscopic intracranial stent placement in adults is rarely required but is a safe and helpful technique in select cases. It is indicated when reliable and long-lasting restoration of CSF pathway obstructions cannot be achieved with standard endoscopic techniques. In the treatment of tumor-related hydrocephalus, it is a good option to avoid reclosure of the restored CSF pathway by tumor growth. Currently, routine stent placement after endoscopic fenestration of ACs is not recommended. Stent placement for treatment of CSF disorders due to tumor is a good option for avoiding CSF shunting. To avoid stent migration and dislocation, and to allow for easy removal if needed, the device should be fixed to a bur hole reservoir.

  16. Multiple pole in the electron--hydrogen-atom scattering amplitude

    International Nuclear Information System (INIS)

    Amusia, M.Y.; Kuchiev, M.Y.

    1982-01-01

    It is demonstrated that the amplitude for electron--hydrogen-atom forward scattering has the third-order pole at the point E = -13.6 eV, E being the energy of the incident electron. The coefficients which characterize the pole are calculated exactly. The invalidity of the Born approximation is proved. The contribution of the pole singularity to the dispersion relation for the scattering amplitude is discussed

  17. Determination of the crystallite orientation distribution from direct pole figures

    International Nuclear Information System (INIS)

    Araujo Gomes, P.A.M. de.

    1977-01-01

    A method is described which allows to calculate the crystallite orientation distribution in polycrystalline material, from direct pole figures data of its crystallographic planes (Roe's Method). The programme was applied to (1010), (0002), (1011) and (1120) complete pole figures data for a commercial, thin sheet Zircaloy-4 tubing specimen. A semi-automatic Rigaku-Denki texture goniometer, which scans the reciprocal lattice sphere pointwise outputting the data in a punched tape, was used to obtain the pole figures. This is consistent with the results obtained through direct conclusion from the pole figures. (author)

  18. South Pole Region of the Moon as Seen by Clementine

    Science.gov (United States)

    1994-01-01

    Lunar mosaic of 1500 Clementine images of the south polar region of the moon. The projection is orthographic, centered on the south pole. The Schrodinger Basin (320 km in diameter) is located in the lower right of the mosaic. Amundsen-Ganswindt is the more subdued circular basin between Schrodinger and the pole. The polar regions of the moon are of special interest because of the postulated occurrence of ice in permanently shadowed areas. The south pole is of greater interest because the area that remains in shadow is much larger than that at the north pole.

  19. Thermal poling of multi-wire array optical fiber

    DEFF Research Database (Denmark)

    Huang, Lin; An, Honglin; Hayashi, Juliano G.

    2018-01-01

    We demonstrate in this paper thermal poling of multi-wire array fibers, which extends poling of fibers with two anodes to similar to 50 and similar to 500 wire array anodes. The second harmonic microscopy observations show that second order nonlinearity (SON) layers are developed surrounding all...... the rings of wires in the similar to 50 anode array fiber with poling of 1.8kV, 250 degrees C and 30min duration, and the outer rings of the similar to 500 anode array fiber at lower poling temperature. Our simulations based on a two-dimensional charge dynamics model confirm this can be explained...

  20. Optimal PMU Placement By Improved Particle Swarm Optimization

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Liu, Leo; Chen, Zhe

    2013-01-01

    This paper presents an improved method of binary particle swarm optimization (IBPSO) technique for optimal phasor measurement unit (PMU) placement in a power network for complete system observability. Various effective improvements have been proposed to enhance the efficiency and convergence rate...... of conventional particle swarm optimization method. The proposed method of IBPSO ensures optimal PMU placement with and without consideration of zero injection measurements. The proposed method has been applied to standard test systems like 17 bus, IEEE 24-bus, IEEE 30-bus, New England 39-bus, IEEE 57-bus system...

  1. Bridging the Poles: Education Linked with Research

    Science.gov (United States)

    Pfirman, S.; Bell, R. E.; Turrin, M.; Maru, P.

    2004-12-01

    An international group of 65 scientists, educators and media specialists gathered at the "Bridging the Poles" workshop in Washington, DC on June 23-25, to define strategies that will inspire the general public and engage the next generation of polar scientists, engineers and leaders. This NSF-sponsored workshop was the first effort to develop an integrated education and outreach program for the International Polar Year of 2007-2009. Through a series of plenary talks and roundtable discussions, workshop participants focused on: engaging diverse communities, opportunities and needs for different levels, possibilities for thematic areas, and programs to feature nationally and internationally over the next 5 years. To maximize the potential of the International Polar Year, we need to coordinate research, education and outreach efforts, at the international as well as national level, with the goal of building an integrated and exciting public presence during 2007-2009. Successful education and outreach programming requires leveraging existing resources, creating new programs, connecting communities, and developing partnerships between agencies, scientists, educators, and the public. We need to consider the rich heritage of indigenous Arctic peoples, build capacity within communities through targeted efforts, and focus on making the poles relevant to diverse communities by using interdisciplinary approaches, e.g. cultural as well as scientific. A series of education and outreach packages for large-scale science endeavors should be rolled out to the public as major media events. The media -- television, radio and print -- as well as educators, zoos and museums are eager to use timely, accessible, and meaningful content. An Interagency Working Group on IPY Education and Outreach, with a staff and a central office, must be created to coordinate and leverage programs. A sophisticated web portal should be developed to serve content and contacts for researchers, educators, the

  2. Familial placement of Wightia (Lamiales)

    DEFF Research Database (Denmark)

    Zhou, Qing-Mei; Jensen, Søren Rosendal; Liu, Guo-Li

    2014-01-01

    The familial placement of Wightia has long been a problem. Here, we present a comprehensive phylogenetic inspection of Wightia based on noncoding chloroplast loci (the rps16 intron and the trnL–F region) and nuclear ribosomal internal transcribed spacer, and on chemical analysis. A total of 70 sa...

  3. Acute complications associated with bedside placement of feeding tubes.

    Science.gov (United States)

    Baskin, William N

    2006-02-01

    Several types of feeding tubes can be placed at a patient's bedside; examples include nasogastric, nasointestinal, gastrostomy, and jejunostomy tubes. Nasoenteral tubes can be placed blindly at bedside or with the assistance of placement devices. Nasoenteric tubes can also be placed via fluoroscopy and endoscopy. Gastrostomy and jejunostomy tubes can be placed using endoscopic techniques. This paper will describe the indications and contraindications for different types of tubes that can be placed at the bedside and complications associated with tube placement. Complications associated with nasoenteral tubes include inadvertent malpositioning of the tube, epistaxis, sinusitis, inadvertent tube removal, tube clogging, tube-feeding-associated diarrhea, and aspiration pneumonia. Complications from percutaneous gastrostomy and jejunostomy tube placements include procedure-related mishaps, site infection, leakage, buried bumper syndrome, tube malfunction, and inadvertent removal. These complications will be reviewed, along with a discussion of incidence, cause, treatment, and prevention approaches.

  4. At the Roots of Product Placement: The Mere Exposure Effect

    Directory of Open Access Journals (Sweden)

    Stefano Ruggieri

    2013-05-01

    Full Text Available The present study aims to analyze the effect of product placement on attitude change and takes into consideration psychological models of the mere exposure effect. A sample of high school students watched an excerpt from two widely-distributed movies in which several products were shown by using the technique known as product placement. The results indicate that students who saw the commercial brand liked the products more than those who didn’t see it. This effect, in line with the literature on the product placement effect, seems to be independent from the recognition of the brand in the movie excerpt. This study also shows that, in the high involvement condition, one exposure is enough to produce a positive attitude toward the brand.

  5. Stone-Free-Rate After Extracorporeal Shockwave Lithotripsy in the Management of Pediatric Renal Stones in Lower Pole and Other Locations - A Comparative Study.

    Science.gov (United States)

    Iqbal, Nadeem; Muhammad, Shujah; Zafar, Warda; Tashfeen, Ravale; Faiz, Javaria; Hasan, Aisha; Hussain, Ijaz; Akhter, Saeed

    2016-11-01

    To determine a difference in the stone-free-rate among different renal locations in children after extracorporeal shockwave lithotripsy (ESWL). A descriptive study. Urology Department, Shifa International Hospital, Islamabad, Pakistan, from January 2007 to June 2015. The study included children who underwent ESWL, divided into three groups based on location of stones in kidney as group A (lower pole stones), group B (upper and mid pole stones) and group C (renal pelvis stone), respectively. ESWL was done by standard technique using Storz Modulith SLX lithotripter 3rd generation. Data was collected by chart review. SPSS version 16 was used for data analysis. Among 76 children with mean age of 7.55 ±4.16 years, 55 (72.4%) were males whereas 21 (27.6%) were females. Mean stone size was 1.08 ±0.59 cm. There were 34, 17 and 25 cases in groups A, B and C, respectively. Post- ESWL stone-free-rate was 47% in lower pole stones, 70.58% in upper and mid pole stones, and 68% in renal pelvis stones. Hematuria was seen in one patient from each group, sepsis in two patients from each of the mid pole/upper pole and lower pole group, while Steinstrasse in one patient from each group. ESWL is a safe and effective way of treating renal stones in all poles in pediatric population.

  6. Development of a neurofeedback protocol targeting the frontal pole using near-infrared spectroscopy.

    Science.gov (United States)

    Kinoshita, Akihide; Takizawa, Ryu; Yahata, Noriaki; Homae, Fumitaka; Hashimoto, Ryuichiro; Sakakibara, Eisuke; Kawasaki, Shingo; Nishimura, Yukika; Koike, Shinsuke; Kasai, Kiyoto

    2016-11-01

    Neurofeedback has been studied with the aim of controlling cerebral activity. Near-infrared spectroscopy is a non-invasive neuroimaging technique used for measuring hemoglobin concentration changes in cortical surface areas with high temporal resolution. Thus, near-infrared spectroscopy may be useful for neurofeedback, which requires real-time feedback of repeated brain activation measurements. However, no study has specifically targeted neurofeedback, using near-infrared spectroscopy, in the frontal pole cortex. We developed an original near-infrared spectroscopy neurofeedback system targeting the frontal pole cortex. Over a single day of testing, each healthy participant (n = 24) received either correct or incorrect (Sham) feedback from near-infrared spectroscopy signals, based on a crossover design. Under correct feedback conditions, significant activation was observed in the frontal pole cortex (P = 0.000073). Additionally, self-evaluation of control and metacognitive beliefs were associated with near-infrared spectroscopy signals (P = 0.006). The neurofeedback system developed in this study might be useful for developing control of frontal pole cortex activation. © 2016 The Authors. Psychiatry and Clinical Neurosciences © 2016 Japanese Society of Psychiatry and Neurology.

  7. A virtual reality based simulator for learning nasogastric tube placement.

    Science.gov (United States)

    Choi, Kup-Sze; He, Xuejian; Chiang, Vico Chung-Lim; Deng, Zhaohong

    2015-02-01

    Nasogastric tube (NGT) placement is a common clinical procedure where a plastic tube is inserted into the stomach through the nostril for feeding or drainage. However, the placement is a blind process in which the tube may be mistakenly inserted into other locations, leading to unexpected complications or fatal incidents. The placement techniques are conventionally acquired by practising on unrealistic rubber mannequins or on humans. In this paper, a virtual reality based training simulation system is proposed to facilitate the training of NGT placement. It focuses on the simulation of tube insertion and the rendering of the feedback forces with a haptic device. A hybrid force model is developed to compute the forces analytically or numerically under different conditions, including the situations when the patient is swallowing or when the tube is buckled at the nostril. To ensure real-time interactive simulations, an offline simulation approach is adopted to obtain the relationship between the insertion depth and insertion force using a non-linear finite element method. The offline dataset is then used to generate real-time feedback forces by interpolation. The virtual training process is logged quantitatively with metrics that can be used for assessing objective performance and tracking progress. The system has been evaluated by nursing professionals. They found that the haptic feeling produced by the simulated forces is similar to their experience during real NGT insertion. The proposed system provides a new educational tool to enhance conventional training in NGT placement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Retratos da metrópole parisiense

    OpenAIRE

    Saint-Julien, Thérèse; Goix, Renaud Le

    2009-01-01

    « La métropole parisienne, centralité, inégalité, proximité » propõe uma leitura e uma interpretação das tendências do território da Île de France (a região que inclui Paris e sete outros départements), ou seja, uma grande metrópole mundial de cerca de 11,3 milhões de habitantes em 2004, ligada às redes da globalização e da metropolização. O livro esboça os traços principais de suas estruturas territoriais emergentes, sublinha os desafios, o alcance dos mesmos e as contradições. Sem pretensão...

  9. Retratos da metrópole parisiense

    Directory of Open Access Journals (Sweden)

    Thérèse Saint-Julien

    2009-07-01

    Full Text Available « La métropole parisienne, centralité, inégalité, proximité » propõe uma leitura e uma interpretação das tendências do território da Île de France (a região que inclui Paris e sete outros départements, ou seja, uma grande metrópole mundial de cerca de 11,3 milhões de habitantes em 2004, ligada às redes da globalização e da metropolização. O livro esboça os traços principais de suas estruturas territoriais emergentes, sublinha os desafios, o alcance dos mesmos e as contradições. Sem pretensão...

  10. Neutron pole figures compared with magnetic preferred orientations of different rock types

    International Nuclear Information System (INIS)

    Hansen, Anke; Chadima, Martin; Cifelli, Francesca; Brokmeier, H.-G.Heinz-Guenter; Siemes, Heinrich

    2004-01-01

    Neutron diffraction is an excellent tool for pole figure measurement of rock samples. Due to high penetration depth of neutrons for most materials neutron diffraction represents an efficient tool to measure complete pole figures with reliable grain statistics even in coarse grained or inequi-granular materials. In the field of structural geology, the measurement of anisotropy of magnetic susceptibility is a standard technique to reveal the tectonic history of deformed rocks. The application of both techniques on still ongoing studies of Precambrian, Carboniferous and Quaternary rocks which are characterised by fundamental different tectonic evolutions and mineralogical compositions shows the wide field of relevance and importance of these methods in understanding tectonic processes in detail

  11. Refinamientos en la reconstrucción del tercio superior auricular con la técnica de Davis: Estudio anatómico y serie clínica Refinements on reconstruction of auricular upper pole defects with Davi's technique: Anatomical study and clinical series

    Directory of Open Access Journals (Sweden)

    S. Llanos

    2009-06-01

    que la técnica de Davis representa un efectivo método de reconstrucción del tercio superior auricular; los refinamientos a la técnica que comunicamos mejoran los resultados, dando un contorno más natural al área reconstruida.Acquired defects of the upper third of the ear constitute a surgical challenge. Several techniques have been described, and results are sometimes unfavorable. An anatomical study in 10 fresh cadavers shows the constant presence of a neurovascular pedicle penetrating the root of helix. Location and vessel diameters are shown. Based on that anatomical knowledge, a series of 10 consecutive cases treated by the senior author is presented. Etiology, surgical technique, complications and long-term results are analyzed. The author's technique introduces a refinement of the Davis' technique, which uses a pedicled chondrocutaneous rotation conchal flap, cutaneous based on the upper auricular branch of superficial temporal artery. An axial pedicled superiorly based retroauricular flap provides the coverage of the new superior helical rim, and the posterior aspect of the chondrocutaneous flap is then covered with a full thickness skin graft. In a second stage, a Z plasty on the root of helix brings it a natural shape All the anatomical dissections demonstrate the presence of a neurovascular pedicle penetrating the root of the helix. The clinical series is composed by 8 traumatic defects, 1 electrical burn and 1 benign skin tumor. All flaps survived and so demonstrated pedicle safety. Two retroauricular flaps presented vascular deficit, one of them with complete spontaneous restoration and the other one with small distal cutaneous necrosis. Two cases suffered partial skin graft loss. Some technical details were developed while the series went on, which are discussed. All 9 patients recovered auricular contour, which seems better for us using the above described refinements. As a conclusion, the Davis's technique represents an effective method to

  12. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.

    NARCIS (Netherlands)

    Guerrero, M.E.; Jacobs, R.; Loubele, M.; Schutyser, F.A.C.; Suetens, P.; Steenberghe, D van

    2006-01-01

    Orofacial diagnostic imaging has grown dramatically in recent years. As the use of endosseous implants has revolutionized oral rehabilitation, a specialized technique has become available for the preoperative planning of oral implant placement: cone beam computed tomography (CT). This imaging

  13. Analyzing block placement errors in SADP patterning

    Science.gov (United States)

    Kobayashi, Shinji; Okada, Soichiro; Shimura, Satoru; Nafus, Kathleen; Fonseca, Carlos; Demand, Marc; Biesemans, Serge; Versluijs, Janko; Ercken, Monique; Foubert, Philippe; Miyazaki, Shinobu

    2016-03-01

    We discuss edge placement errors (EPE) for multi-patterning of Mx critical layers using ArF lithography. Specific focus is placed on the block formation part of the process. While plenty of literature characterization data exist on spacer formation, only limited published data is available on block processes. We analyze the accuracy of placing blocks relative to narrow spacers. Many publications calculate EPE assuming Gaussian distributions for key process variations contributing to EPE. For practical reasons, each contributor is measured on dedicated test structures. In this work, we complement such analysis and directly measure the EPE in product. We perform high density sampling of blocks using CDSEM images and analyze all feature edges of interest. We find that block placement errors can be very different depending on their local design context. Specifically we report on 2 block populations (further called block A and B) which have a 4x different standard deviation. We attribute this to differences in local topography (spacer shape) and interaction with the plasma-etch process design. Block A (on top of the `core space' S1) has excellent EPE uniformity of ~1 nm while block B (on top of `gap space' S2) has degraded EPE control of ~4 nm. Finally, we suggest that the SOC etch process is at the origin on positioning blocks accurately on slim spacers, helping the manufacturability of spacer-based patterning techniques, and helping its extension toward the 5nm node.

  14. Jupiter's interior and deep atmosphere: The initial pole-to-pole passes with the Juno spacecraft

    Science.gov (United States)

    Bolton, S. J.; Adriani, A.; Adumitroaie, V.; Allison, M.; Anderson, J.; Atreya, S.; Bloxham, J.; Brown, S.; Connerney, J. E. P.; DeJong, E.; Folkner, W.; Gautier, D.; Grassi, D.; Gulkis, S.; Guillot, T.; Hansen, C.; Hubbard, W. B.; Iess, L.; Ingersoll, A.; Janssen, M.; Jorgensen, J.; Kaspi, Y.; Levin, S. M.; Li, C.; Lunine, J.; Miguel, Y.; Mura, A.; Orton, G.; Owen, T.; Ravine, M.; Smith, E.; Steffes, P.; Stone, E.; Stevenson, D.; Thorne, R.; Waite, J.; Durante, D.; Ebert, R. W.; Greathouse, T. K.; Hue, V.; Parisi, M.; Szalay, J. R.; Wilson, R.

    2017-05-01

    On 27 August 2016, the Juno spacecraft acquired science observations of Jupiter, passing less than 5000 kilometers above the equatorial cloud tops. Images of Jupiter's poles show a chaotic scene, unlike Saturn's poles. Microwave sounding reveals weather features at pressures deeper than 100 bars, dominated by an ammonia-rich, narrow low-latitude plume resembling a deeper, wider version of Earth's Hadley cell. Near-infrared mapping reveals the relative humidity within prominent downwelling regions. Juno's measured gravity field differs substantially from the last available estimate and is one order of magnitude more precise. This has implications for the distribution of heavy elements in the interior, including the existence and mass of Jupiter's core. The observed magnetic field exhibits smaller spatial variations than expected, indicative of a rich harmonic content.

  15. Spectral analysis of gluonic pole matrix elements for fragmentation

    NARCIS (Netherlands)

    Gamberg, L. P.; Mukherjee, A.B.; Mulders, P.J.G.

    2008-01-01

    The nonvanishing of gluonic pole matrix elements can explain the appearance of single spin asymmetries in high-energy scattering processes. We use a spectator framework approach to investigate the spectral properties of quark-quark-gluon correlators and use this to study gluonic pole matrix

  16. pbx is required for pole and eye regeneration in planarians.

    Science.gov (United States)

    Chen, Chun-Chieh G; Wang, Irving E; Reddien, Peter W

    2013-02-01

    Planarian regeneration involves regionalized gene expression that specifies the body plan. After amputation, planarians are capable of regenerating new anterior and posterior poles, as well as tissues polarized along the anterior-posterior, dorsal-ventral and medial-lateral axes. Wnt and several Hox genes are expressed at the posterior pole, whereas Wnt inhibitory genes, Fgf inhibitory genes, and prep, which encodes a TALE-family homeodomain protein, are expressed at the anterior pole. We found that Smed-pbx (pbx for short), which encodes a second planarian TALE-family homeodomain transcription factor, is required for restored expression of these genes at anterior and posterior poles during regeneration. Moreover, pbx(RNAi) animals gradually lose pole gene expression during homeostasis. By contrast, pbx was not required for initial anterior-posterior polarized responses to wounds, indicating that pbx is required after wound responses for development and maintenance of poles during regeneration and homeostatic tissue turnover. Independently of the requirement for pbx in pole regeneration, pbx is required for eye precursor formation and, consequently, eye regeneration and eye replacement in homeostasis. Together, these data indicate that pbx promotes pole formation of body axes and formation of regenerative progenitors for eyes.

  17. Second harmonic generation from corona-poled polymer thin films ...

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... We characterize thermal stability of second harmonic generation (SHG) properties of four different Y-type polymers poled using corona poling method. These polymers are based on donor–acceptor–donor-type repeating unit with different aromatic moieties acting as donors and dicyanomethylene acting as ...

  18. Derivation of nominal strength for wood utility poles

    Science.gov (United States)

    Ronald W. Wolfe; Jozsef Bodig; Patricia Lebow

    2001-01-01

    The designated fiber stress values published in the American National Standards Institute Standard for Poles, ANSI 05.1, no longer reflect the state of the knowledge. These values are based on a combination of test data from small clear wood samples and small poles (

  19. Second harmonic generation from corona-poled polymer thin films ...

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... Abstract. We characterize thermal stability of second harmonic generation (SHG) properties of four different Y-type polymers poled using corona poling method. These polymers are based on donor–acceptor–donor-type repeating unit with different aromatic moieties acting as donors and dicyanomethylene ...

  20. Three Phase Soft Commutation Auxilary Resonant Pole Inverter

    OpenAIRE

    Vaclav Sladecek

    2006-01-01

    This paper covers the circuit modification of the power part of the inverter with auxiliary resonant poles utilising configuration of switches realised with routinely produced IGBT modules. Covered is also the control optimisation which goal is the minimisation of switching of the auxiliary resonant pole. Presented results were gained on a prototype of an inverter laboratory sample.

  1. Finite element analyses of wood laminated composite poles

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse

    2005-01-01

    Finite element analyses using ANSYS were conducted on orthotropic, polygonal, wood laminated composite poles subjected to a body force and a concentrated load at the free end. Deflections and stress distributions of small-scale and full-size composite poles were analyzed and compared to the results obtained in an experimental study. The predicted deflection for both...

  2. Gluability of out-of-service utility poles

    Science.gov (United States)

    Han Roliadi; Chung Y. Hse; Elvin T. Choong; Todd F. Shupe

    2000-01-01

    This investigation determined the gluability of weathered, out-of-service southern yellow pine (SYP) (Pinus spp.) utility poles. Three types of adhesives were used: resorcinol-phenol formaldehyde (RPF), polyvinyl acetate (PVA), and casein. The poles consisted of two service duration groups: 5 and 25 years. Longer weathering caused greater reduction in creosote content...

  3. Solar Open Flux Migration from Pole to Pole: Magnetic Field Reversal.

    Science.gov (United States)

    Huang, G-H; Lin, C-H; Lee, L C

    2017-08-25

    Coronal holes are solar regions with low soft X-ray or low extreme ultraviolet intensities. The magnetic fields from coronal holes extend far away from the Sun, and thus they are identified as regions with open magnetic field lines. Coronal holes are concentrated in the polar regions during the sunspot minimum phase, and spread to lower latitude during the rising phase of solar activity. In this work, we identify coronal holes with outward and inward open magnetic fluxes being in the opposite poles during solar quiet period. We find that during the sunspot rising phase, the outward and inward open fluxes perform pole-to-pole trans-equatorial migrations in opposite directions. The migration of the open fluxes consists of three parts: open flux areas migrating across the equator, new open flux areas generated in the low latitude and migrating poleward, and new open flux areas locally generated in the polar region. All three components contribute to the reversal of magnetic polarity. The percentage of contribution from each component is different for different solar cycle. Our results also show that the sunspot number is positively correlated with the lower-latitude open magnetic flux area, but negatively correlated with the total open flux area.

  4. Batwing versus Wise pattern mammoplasty for upper pole breast tumours: a detailed comparison of cosmetic outcome.

    Science.gov (United States)

    Hashem, Tarek; Farahat, Ahmed

    2017-03-14

    The aim of this study is to compare the results of batwing mammoplasty and Wise pattern mammoplasty in the surgical management of upper pole breast tumours. This is a retrospective observational study including 126 breast cancer patients who presented between 2009 and 2015 to the National Cancer Institute of Cairo University in Egypt. All patients were candidates for breast conservation, with upper pole tumours, which was defined as tumours between 3 and 9 o'clock. Patients were categorized into two groups. Group A (64) included patients who underwent inferiorly based therapeutic mammoplasty, while group B (62) was designated for patients who had batwing mammoplasty. The results of both groups were compared and analyzed. Wise pattern mammoplasty group had statistically significant higher complication rate. The overall aesthetic result of Wise pattern technique was superior to batwing mammoplasty. However, batwing mammoplasty showed a statistically significant higher rate of patient satisfaction. Both techniques are valid options for upper pole breast tumours. Wise pattern therapeutic mammoplasty remains aesthetically superior; however, batwing mammoplasty is an easy, simple technique with acceptable results to patients.

  5. Separate vertical wiring for the fixation of comminuted fractures of the inferior pole of the patella.

    Science.gov (United States)

    Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo; Yang, Kyu Hyun

    2014-05-01

    Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing.

  6. Pole Dancing Auto-ethnography – Practice, Pedagogy, Performance

    Directory of Open Access Journals (Sweden)

    Amy Patricia Cadwallader

    2017-02-01

    Full Text Available In this research paper, the author addresses the following four questions: 1 What are the implications of bringing pole dancing into concert dance, not as a caricature or theatrical version of what is performed in strip clubs, but as its own, free-standing art form? 2 In what ways will years of ballet and modern dance training influence the type of dancing that emerges from dancers when poles and other apparatuses are introduced? 3 How can the author create an original pole dancing style and pedagogical methods for teaching it? 4 Who participates in pole fitness classes and how does the demographic change based on location? What about when pole fitness classes are offered in an academic setting? The author shares first-hand experiences of investigating pole dancing in fitness classes, attending performances, engaging in a rehearsal process with highly trained dancers, and teaching pole dancing to movers with a wide range of abilities. The author addresses how research plans changed as she encountered limitations of budget and time constraints. The author also elaborates on the creative process that she engaged in with her thesis cast, collaborators, and supporting designers in the making of Super-beneath, a theatrical dance work that uses five, free-standing poles. She outline the vignettes, overall structure, and narrative of the work. The author then discusses where this research fits into the larger field of pole dancing, and the even larger field of dance. In the final sections of this paper, the author describes her pedagogical practices relating to pole classes, what “practice as research” means to her, and how she would like to continue on this research trajectory in the future.

  7. Simplified Analytic Approach of Pole-to-Pole Faults in MMC-HVDC for AC System Backup Protection Setting Calculation

    Directory of Open Access Journals (Sweden)

    Tongkun Lan

    2018-01-01

    Full Text Available AC (alternating current system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC into power grids, it has been a big challenge for the AC system backup protection setting calculation, as the MMC-HVDC lacks the fault self-clearance capability under pole-to-pole faults. This paper focused on the pole-to-pole faults analysis for the AC system backup protection setting calculation. The principles of pole-to-pole faults analysis were discussed first according to the standard of the AC system protection setting calculation. Then, the influence of fault resistance on the fault process was investigated. A simplified analytic approach of pole-to-pole faults in MMC-HVDC for the AC system backup protection setting calculation was proposed. In the proposed approach, the derived expressions of fundamental frequency current are applicable under arbitrary fault resistance. The accuracy of the proposed approach was demonstrated by PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC simulations.

  8. Accuracy of pedicle screw placement in patients with Marfan syndrome.

    Science.gov (United States)

    Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong

    2017-03-21

    There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.

  9. Long-Term Bending Creep Behavior of Thin-Walled CFRP Tendon Pretensioned Spun Concrete Poles

    Directory of Open Access Journals (Sweden)

    Giovanni P. Terrasi

    2014-07-01

    Full Text Available This paper discusses the long-term behavior of a series of highly-loaded, spun concrete pole specimens prestressed with carbon fiber-reinforced polymer (CFRP tendons, which were subjected to outdoor four-point bending creep tests since 1996 in the frame of collaboration with the Swiss precast concrete producer, SACAC (Società Anonima Cementi Armati Centrifugati. The 2 m span cylindrical beams studied are models for lighting poles produced for the last 10 years and sold on the European market. Five thin-walled pole specimens were investigated (diameter: 100 mm; wall-thickness: 25–27 mm. All specimens were produced in a pretensioning and spinning technique and were prestressed by pultruded CFRP tendons. Initially, two reference pole specimens were tested in quasi-static four-point bending to determine the short-term failure moment and to model the short-term flexural behavior. Then, three pole specimens were loaded to different bending creep moments: while the lowest loaded specimen was initially uncracked, the second specimen was loaded with 50% of the short-term bending failure moment and exhibited cracking immediately after load introduction. The highest loaded pole specimen sustained a bending moment of 72% of the short-term bending failure moment for 16.5 years before failing in July 2013, due to the bond failure of the tendons, which led to local crushing of the high-performance spun concrete (HPSC. Besides this, long-term monitoring of the creep tests has shown a limited time- and temperature-dependent increase of the deflections over the years, mainly due to the creep of the concrete. A concrete creep-based model allowed for the calculation of the long-term bending curvatures with reasonable accuracy. Furthermore, the pole specimens showed crack patterns that were stable over time and minimal slippage of the tendons with respect to the pole’s end-faces for the two lower load levels. The latter proves the successful and durable

  10. placements des gouverneurs

    International Development Research Centre (IDRC) Digital Library (Canada)

    André Lavoie

    Transit. Tout endroit qui n'est pas considéré comme la destination où l'on se rend par affaires. Voyageur. Désigne un gouverneur dans le contexte du présent règlement. 5. Rôles et responsabilités. 5.1. Personnes participant au processus lié aux déplacements des gouverneurs. Toutes les personnes, dont les gouverneurs, ...

  11. Heavy Cratering near Callisto's South Pole

    Science.gov (United States)

    1997-01-01

    Images from NASA's Galileo spacecraft provide new insights into this region near Callisto's south pole. This two frame mosaic shows a heavily cratered surface with smooth plains in the areas between craters. North is to the top of the image. The smoothness of the plains appears to increase toward the south pole, approximately 480 kilometers (293 miles) south of the bottom of the image. This smoothness of Callisto's surface was not evident in images taken during the 1979 flyby of NASA's Voyager spacecraft because the resolution was insufficient to show the effect. This smooth surface, and the process(es) that cause it, are among the most intriguing aspects of Callisto. Although not fully understood, the process(es) responsible for this smoothing could include erosion by tiny meteorites and energetic ions. Some craters, such as Keelut, the 47 kilometer (29 mile) crater in the lower right corner, have sharp, well defined rims. Keelut contains an inner ring surrounding a central depression about 17 kilometers (11 miles) in diameter. Keelut, and the more irregularly shaped, degraded Reginleif, the 32 kilometer (19.5 mile) crater in the top center of the image, are very shallow and have flat floors. Crater forms can be seen down to less than 2 kilometers (1.2 miles) in diameter in the image. Each picture element (pixel) in this image is approximately 0.68 kilometers (0.41 miles) across.This image which was taken by the Galileo spacecraft's solid state imaging (CCD) system during its eighth orbit around Jupiter, on May 6th, 1997. The center of the image is located at 71.3 degrees south latitude, 97.6 degrees west longitude, and was taken when the spacecraft was approximately 35,470 kilometers (21,637 miles) from Callisto.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http

  12. Noise generation mechanisms in claw pole alternators

    Science.gov (United States)

    Eversman, W.; Burns, S.; Pekarek, S.; Bai, Hua; Tichenor, J.

    2005-05-01

    Noise of claw pole alternators, generated electromagnetically and structurally radiated, has been the subject of an extensive research program. The goal has been to identify and reduce noise radiation mechanisms in claw pole (Lundell) alternators used in automotive applications. Two approaches have been followed. In the first, electromagnetic sources of noise have been investigated by lumped parameter and magnetically equivalent circuit modeling and simulation, and by related experimentation. This is the subject of separate papers. The second, concurrent study reported here has investigated machine and mount responses to an electromagnetically generated torque ripple. Modeling and experimentation has led to the conclusion that there exists a high correlation between electromagnetic sources, torque ripple, and radiated noise. Experimentation also has led to the conclusion that noise characteristics of a given machine are substantially altered by modification of the mounting configuration. The work reported here involves modeling, simulation, and experiment to isolate machine dynamic characteristics and mounting geometries which contribute to strong coupling between torque ripple and machine/mount dynamic response. A low-order model of the alternator which includes shaft flexibility, gyroscopic effects, shaft bearing asymmetry, mounting lug geometry, and mounting structure dynamics has been created. The model provides a rapid simulation of dynamic response in the form of a transfer function between torque ripple and mounting forces. Generic studies of a simplified mounting structure coupled to the machine model are presented here. Acoustic testing of several machine configurations on a production mount has been carried out to investigate 36th order noise in three phase machines and 72nd order noise in six-phase machines. Electromagnetic modeling and dynamic response simulations suggest that the six-phase machine is inherently quieter. This is supported by

  13. Territorial Balancing of Poles of Development

    Directory of Open Access Journals (Sweden)

    CLAUDIA POPESCU

    2008-01-01

    Full Text Available The paper is part of the study "Specific problems of the development of the settlement network in south-eastern Romania. Regions of development 3 (South, 4 (South-West and 8 (Bucharest-Ilfov" elaborated during 2004 – 2006, within the AMTRANS programme funded by the Ministry of Education and Research, coordinated by INCD – URBANPROIECT in partnership with the Institute of Geography of the Romanian Academy and the Qualification in Statistics National Centre. The general objective of the project was sustainable and balanced spatial development of the settlement network and promotion of new relationships between urban and rural. Concretely, the study has produced a model of a polycentric and balanced settlement network according to the European principles. The case study testing and validating this model took place in southern Romania, territory exhibiting acutely the entire range of problems related to the state of the settlement network: profoundly large rural areas, accentuated dynamics of declaring new cities without sufficient evidence, excessive polarization exercised by Bucharest, etc. The paper presents the intervention directions needed to balance in the territory urban poles within the studied area, focusing on the establishment of orientation policies to consolidate the role of each settlement based on the hierarchical level of importance: European, national, regional, and local. The paper also identifies possible functional urban areas: the metropolitan area of Bucharest, areas of potential strategic integration, areas of cooperation between the small and medium-sized cities and the rural regions. Within each of these areas, the paper proposes to establish new relationships between urban and rural based on partnership, involving cooperation and coordination in achieving common goals.The study considers that the poles of development are the key element of proposed model, and their identification, formation, and balanced distribution

  14. Pole preservatives in soils adjacent to in-service utility poles in the United States. Final report

    International Nuclear Information System (INIS)

    Taylor, B.B.; Ripp, J.A.; Ladwig, K.

    1997-12-01

    As a result of increasing concerns regarding the environmental fate of wood preservatives, EPRI carried out a study of soils in the vicinity of in-service wood pole sites. More than 8,000 soil samples adjacent to 180 PCP-treated and 22 creosote-treated wood poles were collected and analyzed for chemicals of interest. The results showed that concentrations of wood preservative chemicals tended to be highest in soils located in very close proximity to the poles with rapid decreases in concentrations observed with distance from the poles. Soil partitioning, biodegradation, and modeling studies on PCP were also completed to augment the soil data and to provide additional information on the release, migration, and fate of wood preservatives at in-service pole sites

  15. Humanitarian engineering placements in our own communities

    Science.gov (United States)

    VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.

    2010-05-01

    There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be transformative for both the student and the community, although this potential is not always seen. In order to investigate the role of local placements, qualitative research interviews were conducted. Thirty-two semi-structured research interviews were conducted and analysed, resulting in a distinct outcome space. It is concluded that local humanitarian engineering placements greatly complement international placements and are strongly recommended if international placements are conducted. More importantly it is seen that we are better suited to address the marginalised in our own community, although it is often easier to see the needs of an outside populace.

  16. π π scattering by pole extrapolation methods

    International Nuclear Information System (INIS)

    Lott, F.W. III.

    1977-01-01

    A 25-inch hydrogen bubble chamber was used at the Lawrence Berkeley Laboratory Bevatron to produce 300,000 pictures of π + p interactions at an incident momentum of the π + of 2.67 GeV/c. The 2-prong events were processed using the FSD and the FOG-CLOUDY-FAIR data reduction system. Events of the nature π + p → π + pπ 0 and π + p → π + π + n with values of momentum transfer to the proton of -t less than or equal to 0.238 GeV 2 were selected. These events were used to extrapolate to the pion pole (t = m/sub π/ 2 ) in order to investigate the π π interaction with isospins of both T = 1 and T = 2. Two methods were used to do the extrapolation: the original Chew-Low method developed in 1959 and the Durr-Pilkuhn method developed in 1965 which takes into account centrifugal barrier penetration factors. At first it seemed that, while the Durr-Pilkuhn method gave better values for the total π π cross section, the Chew-Low method gave better values for the angular distribution. Further analysis, however, showed that if the requirement of total OPE (one-pion-exchange) were dropped, then the Durr-Pilkuhn method gave more reasonable values of the angular distribution as well as for the total π π cross section

  17. The North Celestial Pole Monitoring Project

    Science.gov (United States)

    Blake, R. M.; Castelaz, M.; Phillips, J.

    2005-05-01

    In the past ten years a renaissance has occurred in the study of transient phenomena using small, dedicated optical telescopes. This has largely been driven by the successful detection of planetary transits with small telescopes (Henry et al. 2000) and the successful recovery of optical afterglows of gamma ray bursts (e.g. Halpern et al. 1997). The telescopes involved are designed to slew at rapid rates accurately across the sky when a burst alert occurs, or to study a single patch of sky to detect transits. We have constructed a dedicated robotic instrument to monitor the region within 4 degrees of the north celestial pole continuously every clear night. Using a sequence of short and long exposures the telescope collects data to conduct searches for transient and variable objects and monitor the Cepheid variable Polaris. Previous authors (Kamper et al. 1984; Evans et al. 1998) have observed Polaris to nearly cease its pulsation, a unique behavior for a Cepheid variable. Monitoring Polaris with high secular coverage should help explain this behavior. We describe here the design of the observatory, its operation and control systems and give preliminary examples of the data products from this unique project.

  18. Study on Pole Arrangement of the CEDM Coils

    International Nuclear Information System (INIS)

    Park, Jin Seok; Lee, Myoung Goo; Kim, Hyun Min; Cho, Yeon Ho; Choi, Taek Sang

    2013-01-01

    The coil stack assembly is important for reliable operation of the CEDM, there have been efforts to improve the design by optimizing the design parameters such as dimensions and winding turns. However, magnetic forces of the CEDM can also change by different pole arrangement even if their design parameters are the same. Since the latch coil and lift coil are installed connected to each other, they produce magnetically coupled field when they are energized at the same time. This coupling field can affect the magnetic force of the CEDM significantly. In this paper, coil pole arrangement effects are studied. Electro-magnetic analysis is performed for the different pole arrangements of the CEDM coils to calculate the magnetic forces. Pole arrangement effects on magnetic forces were studied by static analysis of the CEDM magnetic field. Magnetic forces were calculated and compared for the two different pole arrangements of the coils. The results show that the magnetic poles of the lift coil and latch coil shall be arranged to have the same magnetic pole direction to achieve higher magnetic force

  19. LMI-Based Mixed H2/H∞ Controller Design with Regional Pole Constraints for Damping Power System Oscillations

    Science.gov (United States)

    Hardiansyah; Furuya, Seizo; Irisawa, Juichi

    This paper presents the mixed H2/H∞ controller design with regional pole constraints for damping power system oscillations. The state feedback gain can be obtained by solving a linear matrix inequality (LMI) feasibility problem that robustly assigns the closed-loop poles in a prescribed LMI region. The proposed technique is illustrated with applications to the design of stabilizer for a typical single-machine infinite-bus (SMIB) and a multimachine power system. The LMI-based control ensures adequate damping for widely varying system operating conditions. The simulation results illustrate the effectiveness and robustness of the proposed stabilizer.

  20. Evidence of Space-Charge Effects in Thermal Poling

    DEFF Research Database (Denmark)

    Wu, X.; Arentoft, Jesper; Wong, D.

    1999-01-01

    The in situ thermal poling processes in germanosilicate fibers for positive and negative poling voltages are significantly different. Thermal poling of silica fibers consists of two processes: the faster linear process of charge migration and the subsequent single exponential process of charge...... ionization. Both the shielding electrical field due to charge migration and the ionization electrical field due to charge ionization are able to be frozen-in at room temperature acid lead to the residual linear electrooptic effects, The observations support that the mechanism of the induced electrooptic...... effects is based on space charge electrical fields instead of dipole/bond orientation....

  1. Effect of Dangling Bonds on De-Poling Time for Polymeric Electric Field Optical Sensors

    Directory of Open Access Journals (Sweden)

    Amir R. Ali

    2018-01-01

    Full Text Available This paper investigates the possible chemical changes in polydimethylsiloxane (PDMS caused by two different techniques of fabrication for ultra-sensitive electric field optical sensors. The sensing element is a micro-sphere made from 60:1 PDMS (60 parts base silicon elastomer to one part polymer curing agent by volume. The measurement principle is based on the morphology dependent resonances (MDR shifts of the micro-sphere. We present the effects of curing and poling of polymer micro-spheres used as optical sensors. The degree of curing leads to changes in the de-poling time which results from dangling bonds in the polymeric chains. Consequently, the longevity of the sensitivity of the sensor can extended by two orders of magnitude. An analysis is carried out along with preliminary experiments to investigate that behavior.

  2. PopZ identifies the new pole, and PodJ identifies the old pole during polar growth in Agrobacterium tumefaciens.

    Science.gov (United States)

    Grangeon, Romain; Zupan, John R; Anderson-Furgeson, James; Zambryski, Patricia C

    2015-09-15

    Agrobacterium tumefaciens elongates by addition of peptidoglycan (PG) only at the pole created by cell division, the growth pole, whereas the opposite pole, the old pole, is inactive for PG synthesis. How Agrobacterium assigns and maintains pole asymmetry is not understood. Here, we investigated whether polar growth is correlated with novel pole-specific localization of proteins implicated in a variety of growth and cell division pathways. The cell cycle of A. tumefaciens was monitored by time-lapse and superresolution microscopy to image the localization of A. tumefaciens homologs of proteins involved in cell division, PG synthesis and pole identity. FtsZ and FtsA accumulate at the growth pole during elongation, and improved imaging reveals FtsZ disappears from the growth pole and accumulates at the midcell before FtsA. The L,D-transpeptidase Atu0845 was detected mainly at the growth pole. A. tumefaciens specific pole-organizing protein (Pop) PopZAt and polar organelle development (Pod) protein PodJAt exhibited dynamic yet distinct behavior. PopZAt was found exclusively at the growing pole and quickly switches to the new growth poles of both siblings immediately after septation. PodJAt is initially at the old pole but then also accumulates at the growth pole as the cell cycle progresses suggesting that PodJAt may mediate the transition of the growth pole to an old pole. Thus, PopZAt is a marker for growth pole identity, whereas PodJAt identifies the old pole.

  3. Characterization of Periodically Poled Nonlinear Materials Using Digital Image Processing

    National Research Council Canada - National Science Library

    Alverson, James R

    2008-01-01

    .... A new approach based on image processing across an entire z+ or z- surface of a poled crystal allows for better quantification of the underlying domain structure and directly relates to device performance...

  4. POLE mutations in families predisposed to cutaneous melanoma

    DEFF Research Database (Denmark)

    Aoude, Lauren G; Heitzer, Ellen; Johansson, Peter

    2015-01-01

    Germline mutations in the exonuclease domain of POLE have been shown to predispose to colorectal cancers and adenomas. POLE is an enzyme involved in DNA repair and chromosomal DNA replication. In order to assess whether such mutations might also predispose to cutaneous melanoma, we interrogated...... whole-genome and exome data from probands of 34 melanoma families lacking pathogenic mutations in known high penetrance melanoma susceptibility genes: CDKN2A, CDK4, BAP1, TERT, POT1, ACD and TERF2IP. We found a novel germline mutation, POLE p.(Trp347Cys), in a 7-case cutaneous melanoma family....... Functional assays in S. pombe showed that this mutation led to an increased DNA mutation rate comparable to that seen with a Pol ε mutant with no exonuclease activity. We then performed targeted sequencing of POLE in 1243 cutaneous melanoma cases and found that a further ten probands had novel or rare...

  5. New tilted-poles Wien filter with enhanced performance

    Science.gov (United States)

    Leal-Quiros, E.; Prelas, M. A.

    1989-03-01

    The Wien filter is an E×B deflecting analyzer with the electrostatic field perpendicular to the magnetostatic field. The twofold functions of the Wien filter are as an energy analyzer as well as a mass analyzer. It has very high resolution for paraxial charged-particle beams with V=E/B, the Wien velocity. Two Wien filters, a tilted-poles Wien filter, and a classical parallel-rectangular-poles Wien filter were built and tested for electrons up to 3.5 keV and protons beams of 200 eV. (The tilted-poles Wien filter is a new diagnostic developed by the authors.) The performance of the two is compared, and the tilted-poles Wien filter has superior resolution to the classical Wien filter. Both Wien filters appear to have features useful for high-temperature plasma diagnostics, including simultaneous measurement of energy and mass spectra, and high resolution.

  6. New tilted-poles Wien filter with enhanced performance

    Energy Technology Data Exchange (ETDEWEB)

    Leal-Quiros, E.; Prelas, M.A.

    1989-03-01

    The Wien filter is an E x B deflecting analyzer with the electrostatic field perpendicular to the magnetostatic field. The twofold functions of the Wien filter are as an energy analyzer as well as a mass analyzer. It has very high resolution for paraxial charged-particle beams with V = E/B, the Wien velocity. Two Wien filters, a tilted-poles Wien filter, and a classical parallel-rectangular-poles Wien filter were built and tested for electrons up to 3.5 keV and protons beams of 200 eV. (The tilted-poles Wien filter is a new diagnostic developed by the authors.) The performance of the two is compared, and the tilted-poles Wien filter has superior resolution to the classical Wien filter. Both Wien filters appear to have features useful for high-temperature plasma diagnostics, including simultaneous measurement of energy and mass spectra, and high resolution.

  7. Pacific Albacore Troll and Pole-and-line Fisheries

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The North Pacific and South Pacific Albacore Troll and Pole-and-line Fisheries project contains landings, logbooks, and size composition data from U.S.A. troll and...

  8. Micrometeorites from the South Pole Water Well, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — Micrometeorites dated between 1100 A.D. to 1500 A.D. were collected from the bottom of the South Pole Water Well in December 1995. Element analyses of 181 cosmic...

  9. Methane Isotopes in South Pole Firn Air, 2008, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains depth profiles for delta carbon-13 (δ13C) and delta deuterium (δD) of methane (CH4) in South Pole firn air. The investigators obtained air...

  10. South Pole Snow Pit, 1988 and 1989, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — Information from 6-meter snow pits dug close to the South Pole in austral summer 1988-1989 by the Glacier Research Group of the University of New Hampshire (location...

  11. Dynamic Electromechanical Characterization of Axially Poled PZT 95/5

    International Nuclear Information System (INIS)

    Chhabildas, Lalit C.; Furnish, Michael D.; Montgomery, Stephen T.; Setchell, Robert E.

    1999-01-01

    We are conducting a comprehensive experimental study of the electromechanical behavior of poled PZT 95/5 (lead zirconate titanate). As part of this study, eight plane-wave tests have been conducted on axially poled PZT 95/5 at stress levels ranging from 0.9 to 4.6 GPa, using VISAR and electrical diagnostics. Observed wave velocities were slightly decreased from ultrasonic velocity, by contrast' with unpoled samples. Compression waveforms show a step at 0.6 GPa more marked than for normally poled or unpoled samples; this may correspond to a poling effect on the ferroelectric/antiferroelectric transition. A similar step is observed on release. The released charge upon loading to 0.9 GPa is consistent with nearly complete depoling. Loading to higher stresses gave lower currents (factor of 10), suggesting shock-induced conductivity or electrical breakdown

  12. Multijet final states: exact results and the leading pole approximation

    International Nuclear Information System (INIS)

    Ellis, R.K.; Owens, J.F.

    1984-09-01

    Exact results for the process gg → ggg are compared with those obtained using the leading pole approximation. Regions of phase space where the approximation breaks down are discussed. A specific example relevant for background estimates to W boson production is presented. It is concluded that in this instance the leading pole approximation may underestimate the standard QCD background by more than a factor of two in certain kinematic regions of physical interest

  13. Second-harmonic scanning optical microscopy of poled silica waveguides

    DEFF Research Database (Denmark)

    Pedersen, Kjeld; Bozhevolnyi, Sergey I.; Arentoft, Jesper

    2000-01-01

    Second-harmonic scanning optical microscopy (SHSOM) is performed on electric-field poled silica-based waveguides. Two operation modes of SHSOM are considered. Oblique transmission reflection and normal reflection modes are used to image the spatial distribution of nonlinear susceptibilities...... and limitations of the two operation modes when used for SHSOM studies of poled silica-based waveguides are discussed. The influence of surface defects on the resulting second-harmonic images is also considered. ©2000 American Institute of Physics....

  14. Analysis of the growth poles in esthetic dentistry

    Directory of Open Access Journals (Sweden)

    Andreea Dana Tudose

    2015-05-01

    Full Text Available Growth poles are considered dynamic elements of economic growth, responsible for economical technogical, ideological, spiritual and moral integration.Bioeconomy is currently an area of great and mighty power development. High complexity of this field is to combine the use of technologies that use biological resources in the range of human values involved. This study requires that objective SWOT analysis applied in dental esthetics with strict reference to the quality of work in relation to aesthetic and functional effectiveness of the treatment, the life, the method of reconstruction, working technique, the degree of invasiveness of treatment in relation to conservation dental tissues ,execution costs, costs of resources used in dental anterior segment reconstruction and economic analysis of the modalities of treatment techniques reported the need and level of understanding of patients on treatment aesthetic-functional complexity. As material and method took into account the interaction of four factors: Strenghts-Weaknesses-Opportunities -Hazards. In group “Strengths” we have included successful treatment aesthetic-functional execution moderate cost, short time working on the seat, which shows limited use of natural resources. In group “Weaknesses” I included invasiveness of biological treatment, increased during execution of the work, aesthetic-functional failure , lack of training practitioners in dental aesthetics, lack of existant cabinets to promote interest in aesthetic dental medicine. “Opportunities” referred to the minimally invasive treatment of dental tissue in existing clinical context with predictable results, as higher interest of patients for dental esthetics, raising the standard of care internationally. In group “Risks” (threats I listed: low resistance while works (weak predictability, decreasing purchasing power, changing customer preferences, increase service quality standards. In the second chapter we

  15. Product placement of computer games in cyberspace.

    Science.gov (United States)

    Yang, Heng-Li; Wang, Cheng-Shu

    2008-08-01

    Computer games are considered an emerging media and are even regarded as an advertising channel. By a three-phase experiment, this study investigated the advertising effectiveness of computer games for different product placement forms, product types, and their combinations. As the statistical results revealed, computer games are appropriate for placement advertising. Additionally, different product types and placement forms produced different advertising effectiveness. Optimum combinations of product types and placement forms existed. An advertisement design model is proposed for use in game design environments. Some suggestions are given for advertisers and game companies respectively.

  16. International Youth Conference on the Poles

    Science.gov (United States)

    Church, A. K.; Kuhn, T. S.; Baeseman, J.; Garmulewicz, A.; Raymond, M.; Salmon, R.

    2006-12-01

    The International Polar Year (IPY) is an international effort, involving more than 50 countries, to focus research in both the sciences and social sciences on the world's Polar Regions. In order to secure youth involvement in the IPY, the Youth Steering Committee (YSC) has been formed, aiming specifically to network young polar researchers from all backgrounds enabling collaboration and to involve this group in outreach focused towards other young people. A conference targeted directly at an audience of early career researchers and international youth will be central to fulfilling these aims. The YSC has therefore developed the concept of the International Youth Conference on the Poles (IYCP). Proposed for 2008, this conference will bring together youth from a diverse set of backgrounds and nationalities to discuss the issues affecting the Polar Regions, their effects on a global scale and ways of addressing these issues. The conference will also serve to highlight ongoing IPY research, especially research being undertaken by young researchers, and provide a perennial framework for youth involvement in polar research and policies. The IYCP will run for three days in May 2008, attracting an international youth audience, as well as representatives from polar organizations, teachers, politicians, policy makers, the general public and media. The IYCP will be divided into three sections. Youth Roundtable Discussions will bring youth together to discuss issues affecting the Polar Regions and potential solutions to these. A Young Researchers Conference will provide the opportunity for young researchers working in the Polar Regions to present their work to an interdisciplinary audience. The Polar Fair will provide an interactive environment for youth to learn about the Polar Regions. The IYCP will be of great importance to the IPY because it will serve as the principle venue during the Polar Year where youth from many different disciplines, backgrounds and countries will

  17. Endoscopic ultrasound coil placement of gastric varices: Emerging modality for recurrent bleeding gastric varices

    Directory of Open Access Journals (Sweden)

    Yogesh Harwani

    2014-01-01

    Full Text Available Gastric varices are the probable source of bleeding in 10-36% of patients, with acute variceal bleeding and carry high mortality and rebleeding rates. Till date, cyanoacrylate glue injection is considered as the standard of care but has high complication rate. Endoscopic ultrasound (EUS guided coil placement is a new emerging technique of management of gastric varices. In this case report, we detail the EUS guided coil placement for management of gastric varices after failed glue injections.

  18. Treatment by stereotactic radiotherapy of tumoral injuries after implant placement: preliminary study

    International Nuclear Information System (INIS)

    Meingan, P.; Rio, E.; Labbe-Devilliers, C.; Geffroy, D.; Ricaud-Couprie, M.; Doutriaux-Dumoulin, I.

    2009-01-01

    Objective: to evaluate the interest and the place of stereotactic radiotherapy in the treatment of primitive or secondary tumoral injuries of the liver. To describe the technique of implants placement. Conclusion: the liver stereotactic radiotherapy, after implant placement, seems to be an alternative or complementary therapy to the radiofrequency for patients refused for surgery, with moderated side effects and a noticeable survival. Complementary studies, especially associated to radiofrequency must be considered. (N.C.)

  19. Soft rot decay capabilities and interactions of fungi and bacteria from fumigated utility poles

    Energy Technology Data Exchange (ETDEWEB)

    Wang, C.J.K.; Worrall, J.J. (State Univ. of New York, Syracuse, NY (United States). Coll. of Environmental Science and Forestry)

    1992-11-01

    The objectives were to (1) identify microfungi and bacterial associates isolated from fumigated southern pine poles from EPRI project RP 1471-72, (2) study the soft-rot capabilities of predominant fungi, and (3) study interactions among microorganisms in relation to wood decay. Methods for identification followed standard techniques using morphological and physiological criteria. Soft-rot by microfungi alone and with bacteria was determined as weight loss and anatomical examination of wood blocks using light microscopy and limited electron microscopy. Acinetobacter calcoaceticus was the predominant bacterium. Twenty-one species of microfungi were identified including four new species. A book entitled IDENTIFICATION MANUAL FOR FUNGI FROM UTILITY POLES IN THE EASTERN UNITED STATES was published. An improved soft-rot test was devised. Fifty-one of 84 species (60%) of microfungi from poles tested were soft-rot positive; that is much greater than previously reported. Three types of anatomical damage of wood of pine or birch caused by soft-rot fungi were described. Interaction tests showed that, in some cases, there was a strong synergism between bacteria and fungi in causing weight loss, but results were inconsistent. Although soft rot is often most apparent under conditions of very high moisture, intermediate moisture levels appear to be optimal, as with basidiomycete decayers.

  20. Soft rot decay capabilities and interactions of fungi and bacteria from fumigated utility poles

    International Nuclear Information System (INIS)

    Wang, C.J.K.; Worrall, J.J.

    1992-11-01

    The objectives were to (1) identify microfungi and bacterial associates isolated from fumigated southern pine poles from EPRI project RP 1471-72, (2) study the soft-rot capabilities of predominant fungi, and (3) study interactions among microorganisms in relation to wood decay. Methods for identification followed standard techniques using morphological and physiological criteria. Soft-rot by microfungi alone and with bacteria was determined as weight loss and anatomical examination of wood blocks using light microscopy and limited electron microscopy. Acinetobacter calcoaceticus was the predominant bacterium. Twenty-one species of microfungi were identified including four new species. A book entitled IDENTIFICATION MANUAL FOR FUNGI FROM UTILITY POLES IN THE EASTERN UNITED STATES was published. An improved soft-rot test was devised. Fifty-one of 84 species (60%) of microfungi from poles tested were soft-rot positive; that is much greater than previously reported. Three types of anatomical damage of wood of pine or birch caused by soft-rot fungi were described. Interaction tests showed that, in some cases, there was a strong synergism between bacteria and fungi in causing weight loss, but results were inconsistent. Although soft rot is often most apparent under conditions of very high moisture, intermediate moisture levels appear to be optimal, as with basidiomycete decayers

  1. A capsular-based vascularized distal radius graft for proximal pole scaphoid pseudarthrosis.

    Science.gov (United States)

    Sotereanos, Dean G; Darlis, Nickolaos A; Dailiana, Zoe H; Sarris, Ioannis K; Malizos, Konstantinos N

    2006-04-01

    To evaluate the clinical results of the application of a capsular-based dorsal distal radius vascularized bone graft in scaphoid proximal pole nonunions. Thirteen patients with symptomatic nonunion at the proximal pole of the scaphoid (10 with avascular necrosis) were treated and reviewed retrospectively. The vascularized bone graft was harvested from the distal aspect of the dorsal radius and was attached to a wide distally based strip of the dorsal wrist capsule. It was inserted press-fit into a dorsal trough across the nonunion site after scaphoid fixation with a Herbert screw. After a mean follow-up period of 19 months 10 of the 13 nonunions (8 of the 10 with avascular necrosis) achieved solid bone union. No complications other than the 3 persistent nonunions occurred. Results of the use of a capsular-based vascularized bone graft from the distal radius for proximal pole scaphoid nonunions compare favorably with the results of pedicled or free vascularized grafts. It is a simple technique that eliminates the need for dissection of small-caliber pedicle or microsurgical anastomoses. No donor site morbidity was observed. Therapeutic, Level IV.

  2. Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts

    Energy Technology Data Exchange (ETDEWEB)

    Sane, S.S.; Towbin, A.; Bergey, E.A.; Kaye, R.D.; Fitz, C.R.; Albright, L.; Towbin, R.B. [Department of Radiology, Children`s Hospital of Pittsburgh, 3705 Fifth Avenue, Pittsburgh, PA 15213 (United States)

    1998-07-01

    Objective. The purpose of this study is to determine the risk of CNS and/or peritoneal infection in children with ventriculoperitoneal shunts in whom a percutaneous gastrostomy tube is placed. Materials and methods. We placed 205 gastrostomy or gastrojejunostomy tubes from January of 1991 to December 1996. Twenty-three patients (10 boys, 13 girls) had ventriculoperitoneal shunts at the time of placement. All shunts were placed at least 1 month prior to placement of the gastrostomy tube. The patients ranged in age from 8 months to 16 years with a mean age of 6 years, 9 months. Patient weight ranged from 2 kg to 60 kg. All 23 children required long-term nutritional support due to severe neurologic impairment. No prophylactic antibiotics were given prior to the procedure. Of the patients, 21/23 had a 14-F Sacks-Vine gastrostomy tube with a fixed terminal retention device inserted, using percutaneous fluoroscopic antegrade technique. Two of the 23 patients had a Ross 14-F Flexi-flo gastrostomy tube which required a retrograde technique due to a small caliber esophagus in these children. Results. All 23 children had technically successful placements of percutaneous gastrostomy (7) or gastrojejunostomy (16) tubes. Of the children, 21/23 (91 %) had no complications from the procedure. Two of 23 (9 %) patients demonstrated signs of peritonitis after placement of their gastrostomy tubes and subsequently had shunt infections. In both, children CSF culture grew gram-positive cocci. The antegrade technique was used in both children who developed peritonitis. Conclusion. Our study indicates children with ventriculoperitoneal shunts who undergo percutaneous gastrostomy are at greater risk for infection and subsequent shunt malfunction. Therefore, we recommend prophylactic antibiotic therapy to cover for skin and oral flora. (orig.) With 1 fig., 7 refs.

  3. Optimal sensor placement in integrated gasification combined cycle power systems

    International Nuclear Information System (INIS)

    Lee, Adrian J.; Diwekar, Urmila M.

    2012-01-01

    Highlights: ► Addresses the sensor placement problem in advanced power system. ► Presents the problem as a stochastic programming problem. ► Considers fisher information based objectives along with the economics of sensor. ► For the first time addresses the problem of sensor placement in advanced power systems. -- Abstract: The optimal sensor placement problem involves determining the most effective locations to place a network of sensors across an array of measurable signals, in accordance with a set of specified objectives and constraints, such as cost, performance, and sensitivity to variations in uncertain environments. In advanced power systems, such as in pulverized coal and integrated gasification combined cycle power plants, the placement of sensors on-line within the power generation process can be expensive or technically infeasible due to certain harsh environments. This paper uses advanced modeling techniques to simulate the system’s steady state behavior, and to capture the variability in unknown process variables using the accuracy information from a given set of online sensors. This variability and measurement error is analyzed using a technique from information theory to determine the most cost-effective network of on-line sensors by formulating a nonlinear, stochastic binary integer problem. The solution is achieved by using an efficient sampling technique, Better Optimization algorithm for Nonlinear Uncertain Systems. The key contribution of using Fisher information as a metric for observation order is that it generalizes the Gaussian assumption on representing process and measurement variability for systems governed by nonlinear dynamics.

  4. Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts

    International Nuclear Information System (INIS)

    Sane, S.S.; Towbin, A.; Bergey, E.A.; Kaye, R.D.; Fitz, C.R.; Albright, L.; Towbin, R.B.

    1998-01-01

    Objective. The purpose of this study is to determine the risk of CNS and/or peritoneal infection in children with ventriculoperitoneal shunts in whom a percutaneous gastrostomy tube is placed. Materials and methods. We placed 205 gastrostomy or gastrojejunostomy tubes from January of 1991 to December 1996. Twenty-three patients (10 boys, 13 girls) had ventriculoperitoneal shunts at the time of placement. All shunts were placed at least 1 month prior to placement of the gastrostomy tube. The patients ranged in age from 8 months to 16 years with a mean age of 6 years, 9 months. Patient weight ranged from 2 kg to 60 kg. All 23 children required long-term nutritional support due to severe neurologic impairment. No prophylactic antibiotics were given prior to the procedure. Of the patients, 21/23 had a 14-F Sacks-Vine gastrostomy tube with a fixed terminal retention device inserted, using percutaneous fluoroscopic antegrade technique. Two of the 23 patients had a Ross 14-F Flexi-flo gastrostomy tube which required a retrograde technique due to a small caliber esophagus in these children. Results. All 23 children had technically successful placements of percutaneous gastrostomy (7) or gastrojejunostomy (16) tubes. Of the children, 21/23 (91 %) had no complications from the procedure. Two of 23 (9 %) patients demonstrated signs of peritonitis after placement of their gastrostomy tubes and subsequently had shunt infections. In both, children CSF culture grew gram-positive cocci. The antegrade technique was used in both children who developed peritonitis. Conclusion. Our study indicates children with ventriculoperitoneal shunts who undergo percutaneous gastrostomy are at greater risk for infection and subsequent shunt malfunction. Therefore, we recommend prophylactic antibiotic therapy to cover for skin and oral flora. (orig.)

  5. Gastrojejunoscopy facilitates placement of a percutaneous transgastric jejunostomy in a patient with a pancreaticoduodenectomy and multiple-failed feeding tube placements

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2018-02-01

    Full Text Available Enteral access is one of the most common procedures performed in abdominal and interventional radiology. The surgical anatomy of the postoperative stomach may, however, make enteral access challenging. This report describes a patient with a pancreaticoduodenectomy complicated by a gastrojejunostomy leak who underwent 2 unsuccessful transoral endoscopic nasojejunal tube placements and 2 failed percutaneous gastrojejunostomy tube placements. Eventually, a gastrojejunostomy tube was placed utilizing percutaneous techniques with fluoroscopy assistance and gastrojejunoscopy guidance. A combined technique with fluoroscopy and endoscopy, both controlled by interventional radiology, may be useful in patients with complex postsurgical gastrointestinal anatomy who require enteral access.

  6. Patellar Shape-Memory Fixator for the Treatment of Comminuted Fractures of the Inferior Pole of the Patella

    Science.gov (United States)

    Liu, Xin-Wei; Shang, Hui-Juan; Xu, Shuo-Gui; Wang, Zhi-Wei; Zhang, Chun-Cai; Fu, Qing-Ge

    2011-07-01

    Comminuted and displaced fractures of the inferior pole of the patella are not easy to reduce and it is difficult to fix the fragments soundly enough to allow early movement of the knee. The purpose of this study is to evaluate the clinical effectiveness of the internal fixation technique with Patellar Shape-Memory Fixator (PSMF) in acute comminuted fractures of the inferior pole of the patella. We retrospectively studied 25 patients with comminuted fractures of the inferior pole of the patella who were treated with PSMF and followed up for a mean period of 26 months (14 to 60). All the fractures healed at a mean of 6 weeks (5 to 7). The mean grading at the final follow-up was 29.5 points (27 to 30) using the Bostman score, with no observable restriction of movement. No breakage of the PSMF or infection occurred. No delayed union, nonunion, and infection were seen. This technique preserved the length of the patella, reduced the comminuted fragments of the inferior pole and avoided long-term immobilization of the knee.

  7. Efficacy of the lithotripsy in treating lower pole renal stones.

    Science.gov (United States)

    Cui, Helen; Thomee, Eeke; Noble, Jeremy G; Reynard, John M; Turney, Benjamin W

    2013-06-01

    Use of extracorporeal lithotripsy is declining in North America and many European countries despite international guidelines advocating it as a first-line therapy. Traditionally, lithotripsy is thought to have poor efficacy at treating lower pole renal stones. We evaluated the success rates of lithotripsy for lower pole renal stones in our unit. 50 patients with lower pole kidney stones ≤15 mm treated between 3/5/11 and 19/4/12 were included in the study. Patients received lithotripsy on a fixed-site Storz Modulith SLX F2 lithotripter according to a standard protocol. Clinical success was defined as stone-free status or asymptomatic clinically insignificant residual fragments (CIRFs) ≤3 mm at radiological follow-up. The mean stone size was 7.8 mm. The majority of stones (66 %) were between 5 and 10 mm. 28 % of stones were between 10 and 15 mm. For solitary lower pole stones complete stone clearance was achieved in 63 %. Total stone clearance including those with CIRFs was achieved in 81 % of patients. As expected, for those with multiple lower pole stones the success rates were lower: complete clearance was observed in 39 % and combined clearance including those with CIRFs was 56 %. Overall, complete stone clearance was observed in 54 % of patients and clearance with CIRFs was achieved in 72 % of patients. Success rate could not be attributed to age, stone size or gender. Our outcome data for the treatment of lower pole renal stones (≤15 mm) compare favourably with the literature. With this level of stone clearance, a non-invasive, outpatient-based treatment like lithotripsy should remain the first-line treatment option for lower pole stones. Ureteroscopy must prove that it is significantly better either in terms of clinical outcome or patient satisfaction to justify replacing lithotripsy.

  8. Understanding Successful Sandwich Placements: A Bourdieusian Approach

    Science.gov (United States)

    Clark, Martyn; Zukas, Miriam

    2016-01-01

    Sandwich placements and other integrated work and study schemes are increasingly advocated as a key means by which universities can promote students' employability. However, there is little understanding of how successful placements work in terms of facilitating learning and development. Drawing on three longitudinal case studies of students who…

  9. Percutaneous Placement of Peritoneal Dialysis Catheters in ...

    African Journals Online (AJOL)

    Background: The percutaneous placement of peritoneal dialysis (PD) catheters using conscious sedation with ultrasound and fluoroscopic guidance is underutilised and hasseveral advantages over the open surgical and laparoscopic placement methods, especially in the resource-limited developing world. Objectives: To ...

  10. Clitoral Pain Following Retropubic Midurethral Sling Placement

    Directory of Open Access Journals (Sweden)

    Melanie Christofferson, DO

    2015-12-01

    Conclusion: Clitoral pain symptoms following placement of a retropubic midurethral sling should be evaluated and promptly addressed, given the potential negative impact on the patient's sexual function. Christofferson M, Barnard J, and Montoya TI. Clitoral pain following retropubic midurethral sling placement. Sex Med 2015;3:346–348.

  11. Private Placement Debt Financing for Public Entities

    Science.gov (United States)

    Holman, Lance S.

    2010-01-01

    Private placement financing is a debt or capital lease obligation arranged between a municipality or a 501(c) (3) not-for-profit organization and a single sophisticated institutional investor. The investor can be a bank, insurance company, finance company, hedge fund, or high-net worth individual. Private placement financing is similar to…

  12. 32 CFR 1656.10 - Job placement.

    Science.gov (United States)

    2010-07-01

    ... will be reassigned in accordance with § 1656.12. (c) In making job interview referrals and in making... 32 National Defense 6 2010-07-01 2010-07-01 false Job placement. 1656.10 Section 1656.10 National....10 Job placement. (a) Selective Service will maintain a job bank for the exclusive purpose of placing...

  13. Genetic Algorithm Approaches for Actuator Placement

    Science.gov (United States)

    Crossley, William A.

    2000-01-01

    This research investigated genetic algorithm approaches for smart actuator placement to provide aircraft maneuverability without requiring hinged flaps or other control surfaces. The effort supported goals of the Multidisciplinary Design Optimization focus efforts in NASA's Aircraft au program. This work helped to properly identify various aspects of the genetic algorithm operators and parameters that allow for placement of discrete control actuators/effectors. An improved problem definition, including better definition of the objective function and constraints, resulted from this research effort. The work conducted for this research used a geometrically simple wing model; however, an increasing number of potential actuator placement locations were incorporated to illustrate the ability of the GA to determine promising actuator placement arrangements. This effort's major result is a useful genetic algorithm-based approach to assist in the discrete actuator/effector placement problem.

  14. A literature review on optimum meter placement algorithms for distribution state estimation

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, L. [Jadavpur Univ., Kolkotta (India); Chowdhury, S.P.; Chowdhury, S.; Gaunt, C.T. [Cape Town Univ., (South Africa)

    2009-07-01

    A literature review of meter placement for the monitoring of power distribution systems was presented. The aim of the study was to compare different algorithms used for solving optimum meter placement. The percentage of algorithms used and the number of studies conducted to determine optimal placement were plotted on graphs in order to determine the performance accuracy for different meter placement algorithms. Measurements used for state estimation were collected through SCADA systems. The data requirements for real time monitoring and the control of distribution systems were identified using a rule-based meter placement method. Rules included placing meters at all switch and fuse locations that require monitoring; placing additional meters along feeder line sections; placing meters on open tie switches that are used for feeder switching. The genetic algorithm technique was used to consider both the investment costs and real-time monitoring capability of the meters. It was concluded that the branch-current-based 3-phase state estimation algorithm can be used to determine optimal meter placements for distribution systems. The method allowed for the placement of fewer meters. 24 refs., 1 tab., 3 figs.

  15. Orbital exenteration and placement of a prosthesis in fish.

    Science.gov (United States)

    Nadelstein, B; Bakal, R; Lewbart, G A

    1997-09-01

    To develop a procedure for orbital exenteration and prosthesis placement in fish. Prospective study. 5 cultured hybrid striped bass (Morone saxatilis x M chrysops) ranging from 30 to 50 cm in length. Exenteration was performed, using a dorsal approach in which blunt dissection was performed in the circumorbital sulcus. The orbit was then dried, and simple interrupted sutures were placed, leaving 2 suture loops within the orbit. The orbit was filled with polyvinylsiloxane, and a prosthetic glass eye was seated in the polyvinylsiloxane. All fish retained the prosthesis and had satisfactory cosmetic results at the end of the 8-week study period. The increase in popularity of pet fish and abundance of valuable aquarium and show fish have led to heightened awareness of piscine ocular disease. Aquarium fish are often euthanatized because of disfiguring ocular problems. The technique described here for surgical exenteration and cosmetic orbital prosthesis placement in fish may extend the captive life of public display fish.

  16. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  17. Analysis of car’s frontal collision against pole

    Science.gov (United States)

    Ispas, N.; Nastasoiu, M.

    2017-10-01

    Reducing the effects of traffic accidents over the occupants is a major objective of collision attempts. Impacts between the car and the pole are very dangerous for the physical integrity of the car’s occupants. To minimalize the effects of such events on the passengers of a vehicle, a whole series of efforts by both designers and experienced engineers led to increasingly the vehicles safety. The main aim of these paper is to quantify the influences over the car passengers of loads involved by car against pole collisions using the same car model at different speeds. Also, this kind on occupant influences were study using a small car model. Other goal of the paper was the study of the cars stiffness in frontal collision against the pole. The paper’s experimental results were obtained by support of DSD, Dr. Steffan Datentechnik GmbH - Linz, Austria. The described tests were performed in full test facility of DSD Linz, in “Easter 2016 PC-Crash Seminar”. Cars accelerations, velocities, rotations angles after pole impact were registered and discussed. The novelty of the paper consists in studies referred for the same car model involved in car against pole collisions at different impact speeds. Paper’s conclusions can be future used for car safety improvement.

  18. Poles in the Dutch Cape Colony 1652-1814

    Directory of Open Access Journals (Sweden)

    Kowalski Mariusz

    2015-06-01

    Full Text Available The contribution of Poles to the colonisation and development of the Dutch Cape Colony is not commonly known. Yet, Poles have been appearing in this colony since its very inception (1652. During the entire period considered here the presence of Poles was the result of the strong economic ties between Poland and the Netherlands. At the end of this period there was an increase in their share, in connection with the presence of numerous alien military units on the territory of the Colony, because of Poles having served in these units. Numerous newcomers from Poland settled in South Africa for good, established families, and their progeny made up part of the local society. The evidence of this phenomenon is provided by the present-day Afrikaner families of, for instance, Drotsky, Kitshoff, Kolesky, Latsky, Masuriek, Troskie, Zowitsky, and others. A quite superficial estimation implies that the settlers coming from Poland could make up a bit over 1% of the ancestors of the present-day Afrikaners. Poles would also participate in the pioneering undertakings within the far-off fringes of the Colony, including the robbery-and-trade expedition of 1702.

  19. Assessment of Pole Erosion in a Magnetically Shielded Hall Thruster

    Science.gov (United States)

    Mikellides, Ioannis G.; Ortega, Alejandro L.

    2014-01-01

    Numerical simulations of a 6-kW laboratory Hall thruster called H6 have been performed to quantify the erosion rate at the inner pole. The assessments have been made in two versions of the thruster, namely the unshielded (H6US) and magnetically shielded (H6MS) configurations. The simulations have been performed with the 2-D axisymmetric code Hall2De which employs a new multi-fluid ion algorithm to capture the presence of low-energy ions in the vicinity of the poles. It is found that the maximum computed erosion rate at the inner pole of the H6MS exceeds the measured rate of back-sputtered deposits by 4.5 times. This explains only part of the surface roughening that was observed after a 150-h wear test, which covered most of the pole area exposed to the plasma. For the majority of the pole surface the computed erosion rates are found to be below the back-sputter rate and comparable to those in the H6US which exhibited little to no sputtering in previous tests. Possible explanations for the discrepancy are discussed.

  20. Absorption Measurements of Periodically Poled Potassium Titanyl Phosphate (PPKTP at 775 nm and 1550 nm

    Directory of Open Access Journals (Sweden)

    Jessica Steinlechner

    2013-01-01

    Full Text Available The efficient generation of second-harmonic light and squeezed light requires non-linear crystals that have low absorption at the fundamental and harmonic wavelengths. In this work the photo-thermal self-phase modulation technique is exploited to measure the absorption coefficient of periodically poled potassium titanyl phosphate (PPKTP at 1,550 nm and 775 nm. Themeasurement results are (84±40 ppm/cmand (127±24 ppm/cm, respectively. We conclude that the performance of state-of-the-art frequency doubling and squeezed light generation in PPKTP is not limited by absorption.

  1. Electromagnetic Radial Forces in a Hybrid Eight-Stator-Pole, Six-Rotor-Pole Bearingless Switched-Reluctance Motor

    Science.gov (United States)

    Morrison, Carlos R.; Siebert, Mark W.; Ho, Eric J.

    2007-01-01

    Analysis and experimental measurement of the electromagnet force loads on the hybrid rotor in a novel bearingless switched-reluctance motor (BSRM) have been performed. A BSRM has the combined characteristics of a switched-reluctance motor and a magnetic bearing. The BSRM has an eight-pole stator and a six-pole hybrid rotor, which is composed of circular and scalloped lamination segments. The hybrid rotor is levitated using only one set of stator poles. A second set of stator poles imparts torque to the scalloped portion of the rotor, which is driven in a traditional switched reluctance manner by a processor. Analysis was done for nonrotating rotor poles that were oriented to achieve maximum and minimum radial force loads on the rotor. The objective is to assess whether simple one-dimensional magnetic circuit analysis is sufficient for preliminary evaluation of this machine, which may exhibit strong three-dimensional electromagnetic field behavior. Two magnetic circuit geometries, approximating the complex topology of the magnetic fields in and around the hybrid rotor, were employed in formulating the electromagnetic radial force equations. Reasonable agreement between the experimental results and the theoretical predictions was obtained with typical magnetic bearing derating factors applied to the predictions.

  2. Optimal Sensor Placement for Health Monitoring of High-Rise Structure Based on Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Ting-Hua Yi

    2011-01-01

    Full Text Available Optimal sensor placement (OSP technique plays a key role in the structural health monitoring (SHM of large-scale structures. Based on the criterion of the OSP for the modal test, an improved genetic algorithm, called “generalized genetic algorithm (GGA”, is adopted to find the optimal placement of sensors. The dual-structure coding method instead of binary coding method is proposed to code the solution. Accordingly, the dual-structure coding-based selection scheme, crossover strategy and mutation mechanism are given in detail. The tallest building in the north of China is implemented to demonstrate the feasibility and effectiveness of the GGA. The sensor placements obtained by the GGA are compared with those by exiting genetic algorithm, which shows that the GGA can improve the convergence of the algorithm and get the better placement scheme.

  3. Creating Esthetic Harmony with Nonloading, Fixed Provisional Restoration using Extracted Teeth after Immediate Implant Placement.

    Science.gov (United States)

    Satwalekar, Parth; Satwalekar, Tanushree; Bondugula, Vasanthi; Bhuvaneshwari, B; Harshavardhan, K V; Pasula, Kiran

    2016-04-01

    To make use of fiber-reinforced composite and the patient's own extracted teeth in fabricating a provisional restoration following immediate implant placement. Fiber-reinforced composites offer various possibilities in temporization of osseointegrating implants in the esthetic zone. In this chairside technique, the patient's own extracted teeth with fiber-reinforced composite were used to fabricate a provisional restoration after immediate implant placement. A putty index was made before extracting the teeth and placing the implants as planned. The index and crowns of the extracted teeth were used to make a nonloading, esthetic, chair-side provisional restoration after immediate implant placement. By using the patient's own teeth for pro-visionalization immediately after implant placement, acceptance is greatly enhanced.

  4. Dimensional changes after immediate implant placement with or without simultaneous regenerative procedures: a systematic review and meta-analysis.

    Science.gov (United States)

    Clementini, Marco; Tiravia, Luca; De Risi, Valeria; Vittorini Orgeas, Gianluca; Mannocci, Alice; de Sanctis, Massimo

    2015-07-01

    To analyse alveolar ridge volume changes after immediate implant placement, with or without a regenerative technique. Studies investigating the effect of immediate implant placement on ridge dimensional changes were identified through an electronic search conducted using MEDLINE (PubMed) and EMBASE. Weighted mean changes (WMC) between baseline and follow-up time were calculated and subgroup analysis was performed according to study design, evaluation method and regenerative strategies. After immediate implant placement alone WMC of RCTs showed a loss in width and height of 1.1 mm. After flapless immediate implant placement with immediate provisionalization and a graft WMC showed a loss in width and height of 1.02 mm and 0.79 mm, while after flapped immediate implant placement and a graft WMC showed a gain of 1.79 mm. After immediate implant placement plus a non-resorbable membrane WMC showed a loss in height of 0.07 mm. After immediate implant placement plus a resorbable membrane and a graft WMC showed a gain in height of 1.09 mm. Immediate implant placement does not seem to counteract alveolar ridge modelling after tooth extraction. Furthermore, the currently available evidence does not allow for any conclusive statements regarding the efficacy of a concomitant regenerative technique in preventing the amount of alveolar reduction. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Optimal placement of FACTS devices using optimization techniques: A review

    Science.gov (United States)

    Gaur, Dipesh; Mathew, Lini

    2018-03-01

    Modern power system is dealt with overloading problem especially transmission network which works on their maximum limit. Today’s power system network tends to become unstable and prone to collapse due to disturbances. Flexible AC Transmission system (FACTS) provides solution to problems like line overloading, voltage stability, losses, power flow etc. FACTS can play important role in improving static and dynamic performance of power system. FACTS devices need high initial investment. Therefore, FACTS location, type and their rating are vital and should be optimized to place in the network for maximum benefit. In this paper, different optimization methods like Particle Swarm Optimization (PSO), Genetic Algorithm (GA) etc. are discussed and compared for optimal location, type and rating of devices. FACTS devices such as Thyristor Controlled Series Compensator (TCSC), Static Var Compensator (SVC) and Static Synchronous Compensator (STATCOM) are considered here. Mentioned FACTS controllers effects on different IEEE bus network parameters like generation cost, active power loss, voltage stability etc. have been analyzed and compared among the devices.

  6. Effect of composite type and placement technique on cuspal strain.

    Science.gov (United States)

    Ólafsson, Vilhelm G; Ritter, André V; Swift, Edward J; Boushell, Lee W; Ko, Ching-Chang; Jackson, Gabrielle R; Ahmed, Sumitha N; Donovan, Terence E

    2018-01-01

    To compare the cuspal strain in Class II restorations made with bulk-fill and conventional composite resins. Fifty extracted maxillary premolars were mounted into phenolic rings and divided into five groups (n = 10). Specimens received standardized MOD preparations. A two-step self-etch adhesive was applied and the preparations were restored using a custom matrix as follows: Filtek Supreme Ultra in eight 2-mm increments (FSUI); Filtek Supreme Ultra in bulk (FSUB); SonicFill in bulk (SF); SureFil SDR flow in bulk, covered with a 2-mm occlusal layer of Filtek Supreme Ultra (SDR/FSU); Tetric EvoCeram Bulk Fill in bulk (TEBF). Strain gages bonded to the buccal and lingual cusps recorded cuspal strain during restorations. End strain values were determined and data were subjected to Kruskal-Wallis testing, followed by one-way ANOVA and Tukey´s post hoc test. Combined strain values and standard deviations (in µɛ) were: FSUI: 723 ± 102.8, FSUB: 929.2 ± 571.9, SF: 519.1 ± 80.2, SDR-FSU: 497.4 ± 67.6 and TEBF: 604.5 ± 127.1. A significant difference was found between group FSUI and groups SF, SDR-FSU, and TEBF. Group FSUB showed significantly higher mean strain and greater standard deviation than all other groups due to cuspal fractures, and was thus excluded from the statistical analysis. The tested bulk-fill composite resins exerted less strain onto tooth structure than the incrementally placed conventional composite resin, although the magnitude of generated strain was product-dependent. Bulk-filling with conventional composite resins is contraindicated. Bulk-fill composite resins exerted less strain onto adjacent tooth structure than a traditional composite, even when that composite is was placed incrementally. Bulk-filling with traditional composite resins is unpredictable and contraindicated. © 2017 Wiley Periodicals, Inc.

  7. Traumatic amputation of the left lower renal pole in children

    Energy Technology Data Exchange (ETDEWEB)

    Waxman, J.; Belman, A.B.; Kass, E.J.

    1985-07-01

    Four children between 5 and 10 years old suffered traumatic amputation of the left lower renal pole following flank trauma. All patients were evaluated with excretory urography and isotope renography. The renal scan clearly demonstrated failure of perfusion of the lower renal pole and urinary extravasation, and was believed to be more valuable than the standard excretory urogram as a diagnostic tool. All children were managed similarly: delayed (72 to 96 hours) exploration, simple removal of the amputated segment and insertion of a Penrose drain. They all have done well. The patients were normotensive at followup and had excellent function of the remaining portion of the kidney.

  8. Induction Motor with Switchable Number of Poles and Toroidal Winding

    Directory of Open Access Journals (Sweden)

    MUNTEANU, A.

    2011-05-01

    Full Text Available This paper presents a study of an induction motor provided with toroidal stator winding. The ring-type coils offer a higher versatility in obtaining a different number of pole pairs by means of delta/star and series/parallel connections respectively. As consequence, the developed torque can vary within large limits and the motor can be utilized for applications that require, for example, high load torque values for a short time. The study involves experimental tests and FEM simulation for an induction machine with three configurations of pole pairs. The conclusions attest the superiority of the toroidal winding for certain applications such as electric vehicles or lifting machines.

  9. Challenges of Rover Navigation at the Lunar Poles

    Science.gov (United States)

    Nefian, Ara; Deans, Matt; Bouyssounouse, Xavier; Edwards, Larry; Dille, Michael; Fong, Terry; Colaprete, Tony; Miller, Scott; Vaughan, Ryan; Andrews, Dan; hide

    2015-01-01

    Observations from Lunar Prospector, LCROSS, Lunar Reconnaissance Orbiter (LRO), and other missions have contributed evidence that water and other volatiles exist at the lunar poles in permanently shadowed regions. Combining a surface rover and a volatile prospecting and analysis payload would enable the detection and characterization of volatiles in terms of nature, abundance, and distribution. This knowledge could have impact on planetary science, in-situ resource utilization, and human exploration of space. While Lunar equatorial regions of the Moon have been explored by manned (Apollo) and robotic missions (Lunokhod, Cheng'e), no surface mission has reached the lunar poles.

  10. Pedagogický odkaz Ivana Poledňáka

    OpenAIRE

    Čižinská, Klára

    2017-01-01

    The bachelor thesis covers the personality of Ivan Poledňák and his music-teaching heritage. In the first part his life, his activities in musical educational organizations and teaching at universities in the Czech Republic are described. In the second part his musical pedagogical publications are analysed. The aim of this thesis is to punctuate to his big contribution in music education. KEYWORDS Ivan Poledňák, Musically pedagogical inventiveness, Music-school-tomorrow, 40 radio lectures of ...

  11. Poles Living in Ireland and their Quality of Life

    Directory of Open Access Journals (Sweden)

    Agnieszka NOLKA

    2009-05-01

    Full Text Available The economic growth of Ireland resulted in a significant number of Poles migrating to Ireland following the EU enlargement in 2004. The article explores the quality of life of Poles living in Ireland. Using data from a preliminary survey conducted in 2006, several dimensions of living conditions are analysed, including interpersonal relations, material security, health and healthcare. The study shows that evaluations of almost all aspects of quality of life improved, apart from components such as healthcare and the ability to acquire help from social organisations. Also interpersonal relations, contrary to the initial assumption, were enhanced by migration to Ireland.

  12. Is it possible to reduce the knee joint compression force during level walking with hiking poles?

    DEFF Research Database (Denmark)

    Jensen, S B; Henriksen, M; Aaboe, J

    2010-01-01

    Walking with hiking poles has become a popular way of exercising. Walking with poles is advocated as a physical activity that significantly reduces the loading of the hip, knee and ankle joints. We have previously observed that pole walking does not lead to a reduction of the load on the knee joint....... However, it is unclear whether an increased force transmitted through the poles can reduce the load on the knee joint. Thus, the purpose of the present study was to investigate if an increased load transmitted through the arms to the poles could reduce the knee joint compression force during level walking...... with poles. We hypothesized that an increased pole force would result in a reduction of the knee joint compression force. Gait analyses from 10 healthy subjects walking with poles were obtained. The pole force was measured simultaneously during the gait analyses. The knee joint compression forces were...

  13. From 'third pole' to north pole: a Himalayan origin for the arctic fox.

    Science.gov (United States)

    Wang, Xiaoming; Tseng, Zhijie Jack; Li, Qiang; Takeuchi, Gary T; Xie, Guangpu

    2014-07-22

    The 'third pole' of the world is a fitting metaphor for the Himalayan-Tibetan Plateau, in allusion to its vast frozen terrain, rivalling the Arctic and Antarctic, at high altitude but low latitude. Living Tibetan and arctic mammals share adaptations to freezing temperatures such as long and thick winter fur in arctic muskox and Tibetan yak, and for carnivorans, a more predatory niche. Here, we report, to our knowledge, the first evolutionary link between an Early Pliocene (3.60-5.08 Myr ago) fox, Vulpes qiuzhudingi new species, from the Himalaya (Zanda Basin) and Kunlun Mountain (Kunlun Pass Basin) and the modern arctic fox Vulpes lagopus in the polar region. A highly hypercarnivorous dentition of the new fox bears a striking resemblance to that of V. lagopus and substantially predates the previous oldest records of the arctic fox by 3-4 Myr. The low latitude, high-altitude Tibetan Plateau is separated from the nearest modern arctic fox geographical range by at least 2000 km. The apparent connection between an ancestral high-elevation species and its modern polar descendant is consistent with our 'Out-of-Tibet' hypothesis postulating that high-altitude Tibet was a training ground for cold-environment adaptations well before the start of the Ice Age. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  14. Numerical Study on Guided Wave Propagation in Wood Utility Poles: Finite Element Modelling and Parametric Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    Yang Yu

    2017-10-01

    Full Text Available Recently, guided wave (GW-based non-destructive evaluation (NDE techniques have been developed and considered as a potential candidate for integrity assessment of wood structures, such as wood utility poles. However, due to the lack of understanding on wave propagation in such structures, especially under the effect of surroundings such as soil, current GW-based NDE methods fail to properly account for the propagation of GWs and to contribute reliable and correct results. To solve this critical issue, this work investigates the behaviour of wave propagation in the wood utility pole with the consideration of the influence of soil. The commercial finite element (FE analysis software ANSYS is used to simulate GW propagation in a wood utility pole. In order to verify the numerical findings, the laboratory testing is also conducted in parallel with the numerical results to experimentally verify the effectiveness of developed FE models. Finally, sensitivity analysis is also carried out based on FE models of wood pole under different material properties, boundary conditions and excitation types.

  15. Precordial electrode placement in women.

    Science.gov (United States)

    Macfarlane, P W; Colaco, R; Stevens, K; Reay, P; Beckett, C; Aitchison, T

    2003-03-01

    Precordial ECG electrode positioning was standardised in the early 1940s. However, it has been customary for the V 3 to V 6 electrodes to be placed under the left breast in women rather than in the correct anatomical positions relating to the 4th and 5th interspaces. For this reason, a comparison between the two approaches to chest electrode positioning in women was undertaken. In total 84 women were recruited and ECGs recorded with electrodes in the correct anatomical position and also in the more commonly used positions under the breast. As a separate study, 299 healthy women were recruited to study normal limits of leads V 3 to V 6 recorded with electrodes in the correct anatomical positions and compare them with published normal limits with electrodes in the more commonly used locations. It was shown that there was less variability with electrodes in the correct anatomical positions and that there were significant differences between the new limits of normality compared with the old established limits. Expansion of the database and further analysis of the data is required to make a definitive recommendation with respect to precordial electrode placement in women.

  16. Sensor Placement Optimization using Chama

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Geotechnology and Engineering Dept.; Nicholson, Bethany L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Discrete Math and Optimization Dept.; Laird, Carl Damon [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Discrete Math and Optimization Dept.

    2017-10-01

    Continuous or regularly scheduled monitoring has the potential to quickly identify changes in the environment. However, even with low - cost sensors, only a limited number of sensors can be deployed. The physical placement of these sensors, along with the sensor technology and operating conditions, can have a large impact on the performance of a monitoring strategy. Chama is an open source Python package which includes mixed - integer, stochastic programming formulations to determine sensor locations and technology that maximize monitoring effectiveness. The methods in Chama are general and can be applied to a wide range of applications. Chama is currently being used to design sensor networks to monitor airborne pollutants and to monitor water quality in water distribution systems. The following documentation includes installation instructions and examples, description of software features, and software license. The software is intended to be used by regulatory agencies, industry, and the research community. It is assumed that the reader is familiar with the Python Programming Language. References are included for addit ional background on software components. Online documentation, hosted at http://chama.readthedocs.io/, will be updated as new features are added. The online version includes API documentation .

  17. Bone graft in the treatment of nonunion of the scaphoid with necrosis of the proximal pole: a literature review

    Directory of Open Access Journals (Sweden)

    Antônio Lourenço Severo

    Full Text Available ABSTRACT Scaphoid fractures are the most common fractures of the carpal bones, corresponding to 60%. Of these, 10% progress to nonunion; moreover, 3% can present necrosis of the proximal pole. There are various methods of treatment using vascularized and non-vascularized bone grafts. To evaluate and compare the rate of scaphoid consolidation with necrosis of the proximal pole using different surgical techniques. The authors conducted a review of the literature using the following databases: PubMed and BIREME/LILACS, where 13 case series were selected (ten with use of vascularized bone grafts and three of non-vascularized bone grafts, according to inclusion and exclusion criteria. In most cases VBGs were used, especially those based on the 1,2 intercompartmental supraretinacular artery, due to greater reproducibility in performing the surgical technique.

  18. Bone graft in the treatment of nonunion of the scaphoid with necrosis of the proximal pole: a literature review.

    Science.gov (United States)

    Severo, Antônio Lourenço; Lemos, Marcelo Barreto; Lech, Osvandré Luiz Canfield; Barreto Filho, Danilo; Strack, Daniel Paulo; Candido, Larissa Knapp

    2017-01-01

    Scaphoid fractures are the most common fractures of the carpal bones, corresponding to 60%. Of these, 10% progress to nonunion; moreover, 3% can present necrosis of the proximal pole. There are various methods of treatment using vascularized and non-vascularized bone grafts. To evaluate and compare the rate of scaphoid consolidation with necrosis of the proximal pole using different surgical techniques. The authors conducted a review of the literature using the following databases: PubMed and BIREME/LILACS, where 13 case series were selected (ten with use of vascularized bone grafts and three of non-vascularized bone grafts), according to inclusion and exclusion criteria. In most cases VBGs were used, especially those based on the 1,2 intercompartmental supraretinacular artery, due to greater reproducibility in performing the surgical technique.

  19. Computer guided pre-operative planning and dental implant placement

    Directory of Open Access Journals (Sweden)

    Dušan Grošelj

    2007-05-01

    Full Text Available Background: Implants in dentistry are, besides fixed, removable and maxillofacial prosthodontics, one of the reliable possibility to make functional and aesthetic rehabilitation of the edentulism. Surgical and prosthodontic implant complications are often an inattentive consequence of wrong diagnosis, planning, and placement. In this article we present a technique using a highly advanced software program along with a rapid prototyping technology named stereolithography. A planning software for implant placement needs basically the high quality computed tomographic scan of one or both jaws for making accurate preoperative diagnostics and 3D preoperative plan. Later individual drill guide is designed and generated based on both the CT images and the preoperative planning. The patient specific drill guide transfers the virtual planning to the patient’s mouth at time of surgery.Conclusions: The advantages of computer guided implantology are the better prepared surgery with visualisation of critical anatomic structures, assessment of available bone and data about bone quality, increased confidence for the surgeon, deceased operative time, less frequent use of bone grafts, higher quality of collaboration between specialists and prosthetic lab and better communication with patients. Radiographic examination of the operation field for computer guided planning for implant placement is due to high costs justified as the most important information source on the areas to be implanted.

  20. The MinD protein is a membrane ATPase required for the correct placement of the Escherichia coli division site.

    OpenAIRE

    de Boer, P A; Crossley, R E; Hand, A R; Rothfield, L I

    1991-01-01

    The proper placement of the cell division site in Escherichia coli requires the site-specific inactivation of potential division sites at the cell poles in a process that is mediated by the MinC, MinD and MinE proteins. During the normal division cycle MinD plays two roles. It activates the MinC-dependent mechanism that is responsible for the inactivation of potential division sites and it also renders the division inhibition system sensitive to the topological specificity factor MinE. MinE s...

  1. Plotter of pole figure using data from x-ray diffraction

    International Nuclear Information System (INIS)

    Lima, A.F.

    1990-01-01

    Any polycrystalline aggregate normally has a preferred crystallographic orientation, or texture which depends on its thermal and or mechanical history. Preferred orientation is best described by means of a pole figure. A pole figure is a stereographic projection which shows the variation in pole density with pole orientation, for a selected set of crystal planes. In this work, computer programs was developed to plot pole figures. The corrected intensities are calculated and directly transmitted to the plotter. The different intensities levels are represented by different colors in the pole figure. (author)

  2. Vector Triggering Random Decrement Technique for Higher Identification Accuracy

    DEFF Research Database (Denmark)

    Ibrahim, S. R.; Asmussen, J. C.; Brincker, Rune

    1997-01-01

    Using the Random Decrement (RDD) technique to obtain free response estimates and combining this with time domain modal identification methods to obtain the poles and the mode shapes is aknowledged as a fast and accurate way of analyzing measured responses of structures subjected to ambient loads...... for estimation of both poles and mode shapes. The proposed technique (VRDD) is compared with more commonly used triggering conditions by evaluating modal parameters estimated by time domain technique on simulated data....

  3. Selective Placement Program Coordinator (SPPC) Directory

    Data.gov (United States)

    Office of Personnel Management — List of the Selective Placement Program Coordinators (SPPC) in Federal agencies, updated as needed. Users can filter the list by choosing a state and/or agency name.

  4. Liz Taylor : minu van Gogh pole natsidele kuulunud

    Index Scriptorium Estoniae

    2004-01-01

    Elizabeth Taylor palus kohtult otsust, et talle kuuluvat 15 miljonit dollarit maksvat Vincent van Goghi maali "Vaade Saint-Remy varjupaigale" pole natsid Margarete Mauthneri juudiperekonna käest vägivaldselt ära võtnud. E. Taylori isa ostis maali 1963. a. Londonis oksjonilt

  5. Analytical signal and reduction to pole in the interpretation of ...

    African Journals Online (AJOL)

    Analytical signal and reduction to pole in the interpretation of aeromagnetic data at low magnetic latitudes: a case study of the middle Benue trough, Nigeria. OK Likkason. Abstract. No Abstract. Global Journal of Geological Sciences Vol. 4(1) 2006: 29-38. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL ...

  6. Finite element analysis of boron diffusion in wooden Poles

    DEFF Research Database (Denmark)

    Krabbenhøft, Kristian; Hoffmeyer, Preben; Bechgaard, Carl

    2004-01-01

    The problem of describing the migration of dissolved boron in wood is treated with special reference to the commonly used remedial treatment of wooden poles. The governing equations are derived and discussed together with some of the material parameters required. The equations are solved...

  7. Probability models of the x, y pole coordinates data

    Science.gov (United States)

    Sen, A.; Niedzielski, T.; Kosek, W.

    2008-12-01

    The aim of this study is to find the most appropriate probabilistic model for the x, y pole coordinates time series. We have analyzed the IERS eopc04_05 data set covering the period 1962 - 2008. We have also considered the residual x, y pole coordinate time series, which is computed as the difference between the original data and the corresponding least-squares model of the Chandler circle and annual ellipse. Using the measures of skewness and kurtosis of the empirical distribution of the data, we find that the x, y pole coordinates and the corresponding residuals time series cannot be modeled by a normal (Gaussian) distribution. A normal distribution has zero skewness and a kurtosis value of 3. We have fitted several non- Gaussian distributions to the datasets. They include the Generalized Extreme Value distribution, 4-parameter Beta distribution, Johnson SB and SU distributions, Generalized Pareto distribution and Wakeby distribution. Suitability of these distributions as probabilistic models for the x, y pole coordinates and the corresponding residuals time series are discussed.

  8. Bacterial diversity in snow on North Pole ice floes

    DEFF Research Database (Denmark)

    Hauptmann, Aviaja Zenia Edna Lyberth; Stibal, Marek; Bælum, Jacob

    2014-01-01

    The microbial abundance and diversity in snow on ice floes at three sites near the North Pole was assessed using quantitative PCR and 454 pyrosequencing. Abundance of 16S rRNA genes in the samples ranged between 43 and 248 gene copies per millilitre of melted snow. A total of 291,331 sequences we...

  9. Particles as S-matrix poles: hadron democracy

    International Nuclear Information System (INIS)

    Chew, G.F.

    1989-01-01

    The connection between two theoretical ideas of the 1950s is traced in this article, namely that hadrons are nonfundamental, ''composite'' particles and that all physically observable particles correspond to singularities of an analytic scattering matrix. The S matrix theory developed by Werner Heisenberg in the early forties now incorporated the concepts of unitarity, invariance, analyticity and causality. The meson-exchange force meant that poles must be present in nucleon-nuclear and pion-nucleon scattering as predicted by dispersion relations. Experimental work in accessible regions determined pole residues. Pole residue became associated with force strength and pole position with particle mass. In 1959, the author discovered the so-called ''bootstrap'' theory the rho meson as a force generates a rho particle. By the end of the 1950s it was clear that all hadrons had equal status, each being bound states of other hadrons, sustained by hadron exchange forces and that hadrons are self-generated by an S-matrix bootstrap mechanism that determines all their properties. (UK)

  10. Finite Element Analysis of Boron Diffusion in Wooden Poles

    DEFF Research Database (Denmark)

    Krabbenhøft, Kristian; Hoffmeyer, P.; Bechgaard, C.

    2003-01-01

    The problem of describing the migration of dissolved boron in wood is treated with special reference to the commonly used remedial treatment of wooden poles. The governing equations are derived and discussed together with some of the material parameters required. The equations are solved by the f...... by the finite element method and, finally, results showing the effect of different treatment strategies are presented....

  11. Finite element analysis of boron diffusion in wooden Poles

    DEFF Research Database (Denmark)

    Krabbenhøft, Kristian; Hoffmeyer, Preben; Bechgaard, Carl

    2004-01-01

    The problem of describing the migration of dissolved boron in wood is treated with special reference to the commonly used remedial treatment of wooden poles. The governing equations are derived and discussed together with some of the material parameters required. The equations are solved by the f...... by the finite element method and, finally, results showing the effect of different treatment strategies are presented....

  12. Finite Element Analysis of Boron Diffusion in Wooden Poles

    DEFF Research Database (Denmark)

    Krabbenhøft, Kristian; Hoffmeyer, Preben; Bechgaard, Carl

    2004-01-01

    The problem of describing the migration of dissolved boron in wood is treated with special reference to the commonly used remedial treatment of wooden poles. The governing equations are derived and discussed together with some of the material parameters required. The equations are solved by the f...... by the finite element method and, finally, results showing the effect of different treatment strategies are presented....

  13. Separable pole expansions in four-nucleon bound state calculations

    International Nuclear Information System (INIS)

    Sofianos, S.A.; Fiedeldey, H.; Haberzettl, H.; Sandhas, W.

    1982-04-01

    We compare the utility of the Generalized Unitary Pole Expansion (GUPE) and the Energy-Dependent Pole Expansion (EDPE) for the three-body subsystem amplitudes in four-body state calculations for a variety of separable and local nucleon-nucleon interactions. It is found that, with the EDPE, the four-body binding energy is well reproduced with only two terms each for the (2+2)- and the (3+1)-subsystem, respectively, while the GUPE requires three terms for the (3+1)-channel and four terms for the (2+2)-channel. We thus conclude that pole dominance is of greater importance for the GUPE than for EDPE, which works equally well for both types of subsystems. It is found that both methods, in particular the EDPE, converge more rapidly with increasing repulsion in the two-body interaction, i.e. the more realistic the interaction becomes. Both expansions require similar computing times for a converged calculation and are about 15-20 times faster than the widely used Hilbert-Schmidt Expansion (HSE). The respective merits of the two pole expansions are discussed and compared with the HSE. (orig.)

  14. USA valitsus: Tallinna linnahalli miljardigarantiid pole olemas / Raimo Poom

    Index Scriptorium Estoniae

    Poom, Raimo

    2010-01-01

    USA Eesti-saatkonna teatel pole USA valitsus andnud garantiid mitte ühelegi projektile Tallinnas. Tallinna abilinnapea Taavi Aasa sõnul ei saa USA garantiist teha juttu enne, kui Eesti valitsus selle omakorda garanteerib. Taavi Aasa kirjast rahandusminister Jürgen Ligile

  15. An estimate on the purely imaginary poles of scattering matrix

    International Nuclear Information System (INIS)

    Bozhkov, Y.D.

    1988-12-01

    In this work we obtain two estimates (upper and lower) on the number of purely imaginary poles of the scattering matrix for the wave equation in the exterior of a compact smooth obstacle in R n , n ≥ 3 odd. The method of Lax and Phillips is used. (author). 5 refs

  16. Catapult effect in pole vaulting: is muscle coordination determinant?

    Science.gov (United States)

    Frère, Julien; Göpfert, Beat; Hug, François; Slawinski, Jean; Tourny-Chollet, Claire

    2012-02-01

    This study focused on the phase between the time of straightened pole and the maximum height (HP) of vaulter and aimed at determining the catapult effect in pole vaulting on HP. Seven experienced vaulters performed 5-10 vaults recorded by two video cameras, while the surface electromyography (sEMG) activity of 10 upper limbs muscles was recorded. HP was compared with an estimated maximum height (HP(est)) allowing the computation of a push-off index. Muscle synergies were extracted from the sEMG activity profiles using a non-negative matrix factorization algorithm. No significant difference (p>0.47) was found between HP(est) (4.64±0.21m) and HP (4.69±0.23m). Despite a high inter-individual variability in sEMG profiles, two muscle synergies were extracted for all the subjects which accounted for 96.1±2.9% of the total variance. While, the synergy activation coefficients were very similar across subjects, a higher variability was found in the muscle synergy vectors. Consequently, whatever the push-off index among the pole vaulters, the athletes used different muscle groupings (i.e., muscle synergy vectors) which were activated in a similar fashion (i.e., synergy activation coefficients). Overall, these results suggested that muscle coordination adopted between the time of straightened pole and the maximum height does not have a major influence on HP. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Pole solution in six dimensions as a dimensional reduction model

    Science.gov (United States)

    Ichinose, Shoichi

    2002-01-01

    A solution with the pole configuration in six dimensions is analyzed. It is a dimensional reduction model of Randall-Sundrum type. The soliton configuration is induced by the bulk Higgs mechanism. The boundary condition is systematically solved up to the 6th order. The Riemann curvature is finite everywhere.

  18. Diplodia natalensis , Pole Evans: a causal agent of citrus gummosis ...

    African Journals Online (AJOL)

    Isolations were made from the barks of gummosis-infected citrus trees from orchards of the University of Ghana Agricultural Research Station at Kade. The isolation media used were 1.5% water agar, 1.5% water agar + nystatin and 1.5% water agar + benomyl. Four isolates including Diplodia natalensis Pole Evans, ...

  19. Poled-glass devices: Influence of surfaces and interfaces

    DEFF Research Database (Denmark)

    Fage-Pedersen, Jacob; Jacobsen, Rune Shim; Kristensen, Martin

    2007-01-01

    Devices in periodically poled glass must have a large periodic variation of the built-in field. We show that the periodic variation can be severely degraded by charge dynamics taking place at the external (glass–air) interface or at internal (glass–glass) interfaces if the interfaces have imperfe...

  20. BMP regulates vegetal pole induction centres in early xenopus development.

    Science.gov (United States)

    Nachaliel, N; Re'Em-Kalma, Y; Eshed, O; Elias, S; Frank, D

    1998-10-01

    Bone morphogenetic protein (BMP) plays an important role in mesoderm patterning in Xenopus. The ectopic expression of BMP-4 protein hyperventralizes embryos, whereas embryos expressing a BMP-2/4 dominant-negative receptor (DNR) are hyperdorsalized. Mesoderm is initially induced in the marginal zone by cells in the underlying vegetal pole. While much is known about BMP's expression and role in patterning the marginal zone, little is known about its early role in regulating vegetal mesoderm induction centre formation. The role of BMP in regulating formation of vegetal mesoderm inducing centres during early Xenopus development was examined. Ectopic BMP-4 expression in vegetal pole cells inhibited dorsal mesoderm induction but increased ventral mesoderm induction when recombined with animal cap ectoderm in Nieuwkoop explants. 32-cell embryos injected with BMP-4 RNA in the most vegetal blastomere tier were not hyperdorsalized by LiCl treatment. The ectopic expression of Smad or Mix.1 proteins in the vegetal pole also inhibited dorsal mesoderm induction in explants and embryos. Expression of the BMP 2/4 DNR in the vegetal pole increased dorsal mesoderm induction and inhibited ventral mesoderm induction in explants and embryos. These results support a role for BMP signalling in regulating ventral vegetal and dorsal vegetal mesoderm induction centre formation during early Xenopus development.

  1. Decay resistance of out-of-service utility poles as related to the distribution of residual creosote content

    Science.gov (United States)

    Han Roliadi; Chung Y. Hse; Elvin T. Choong; Todd F. Shupe

    2000-01-01

    Decay resistance of out-of-service poles was investigated to evaluate their effectiveness against biodegradation for possible recycling of these poles for composite products. Decay resistance was related to creosote content and creosote distribution in poles with service durations of 5 and 25 years and also freshly treated poles. Weathering of the poles had caused...

  2. Disclosing brand placement to young children

    OpenAIRE

    De Pauw, Pieter; Hudders, Liselot; Cauberghe, Veroline; De Kuysscher, Charlotte

    2015-01-01

    Purpose – This article examines whether a television brand placement warning cue can alter young children’s susceptibility for advertising effects (i.e., brand attitude) through activating their advertising literacy. The proposed model also puts forward an important moderating role for children’s skeptical attitude toward the brand placement format. Design/methodology/approach – The data were collected among 63 children between 7 and 9 years old (Mage = 8.49; 51% girls) through a single...

  3. Pregnancy Outcomes After Myomectomy With Polytetrafluoroethylene Placement

    OpenAIRE

    Eaton, Jennifer L.; Milad, Magdy P.

    2014-01-01

    Background and Objectives: The aim of this study was to report preliminary data on pregnancy outcomes after myomectomy with placement of an expanded polytetrafluoroethylene adhesion barrier membrane. Methods: In this retrospective case series, 68 women who underwent myomectomy with expanded polytetrafluoroethylene membrane placement between January 1, 2003, and December 31, 2009, were identified. Of these women, 15 subsequently had documented pregnancies and were included in the final dataset...

  4. Règlement institutionnel Déplacements

    International Development Research Centre (IDRC) Digital Library (Canada)

    Julie Pépin

    placements et toutes les réservations connexes conformément au présent règlement. Toutes les personnes qui voyagent pour le Centre doivent avoir recours aux services de cette agence pour l'obtention de conseils, de réservations et de titres de transport aux fins de tous les déplacements payés par le CRDI (transport ...

  5. Multiple immediate implants placement with immediate loading

    OpenAIRE

    Narang, Sumit; Narang, Anu; Jain, Kapil; Bhatia, Vineet

    2014-01-01

    The replacement of missing teeth with implant-borne restorations has become a treatment modality accepted by the scientific community for fully and partially edentulous patients. Recent reports have demonstrated the successful placement of dental implants into the fresh extraction socket in the anterior as well as in molar regions, which is made possible due to modification in implant surface. The present case report highlights the placement of three bicortical screw (BCS) implants into the f...

  6. Immediate Implant Placement: Report of Case Series

    Directory of Open Access Journals (Sweden)

    Koray M.

    2015-07-01

    Full Text Available Objective: The aim of this study was to evaluate the outcome of immediate postextraction implant placement. Immediate placement of dental implants have been claimed of the potential advantages such as reductions in the number of surgical interventions, a shorter treatment time, an ideal 3-dimensional implant positioning, the presumptive preservation of alveolar bone at the site of the tooth extraction and soft tissue aesthetics.

  7. Academic achievement and course taking among language minority youth in U.S. schools: Effects of ESL placement

    Science.gov (United States)

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra

    2014-01-01

    The 1974 Lau decision requires that U.S. public schools ensure a meaningful education for students learning English. English as a Second Language (ESL) placement is an institutional response to the linguistic needs of these students; however, its academic implications remain largely unexplored. Using nationally representative data from the Educational Longitudinal Study (ELS), the effects of ESL placement on college preparatory course enrollment and academic achievement of language minority students are estimated, first with fixed effects regression models and then with multi-level propensity score matching techniques. While numerous school and individual level factors beyond language proficiency predict ESL placement, a significant negative estimated effect of ESL placement on science enrollment and cumulative GPA is consistently found. Perhaps more important, however, no positive effects of ESL placement on the achievement of language minority youth are found when accounting for English proficiency and other potential covariates. PMID:25431506

  8. Academic achievement and course taking among language minority youth in U.S. schools: Effects of ESL placement.

    Science.gov (United States)

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra

    2010-03-01

    The 1974 Lau decision requires that U.S. public schools ensure a meaningful education for students learning English. English as a Second Language (ESL) placement is an institutional response to the linguistic needs of these students; however, its academic implications remain largely unexplored. Using nationally representative data from the Educational Longitudinal Study (ELS), the effects of ESL placement on college preparatory course enrollment and academic achievement of language minority students are estimated, first with fixed effects regression models and then with multi-level propensity score matching techniques. While numerous school and individual level factors beyond language proficiency predict ESL placement, a significant negative estimated effect of ESL placement on science enrollment and cumulative GPA is consistently found. Perhaps more important, however, no positive effects of ESL placement on the achievement of language minority youth are found when accounting for English proficiency and other potential covariates.

  9. The Placement History Chart: A Tool for Understanding the Longitudinal Pattern of Foster Children's Placements.

    Science.gov (United States)

    Kim, Hyoun K; Pears, Katherine C; Fisher, Philip A

    2012-08-01

    Despite growing concerns about foster placement instability, little information is available regarding the longitudinal patterns of placement histories among foster children. The purpose of the present study was to develop a charting system using child welfare records to facilitate a better understanding of longitudinal patterns of placement history for 117 foster children. The resulting Placement History Chart included all placements that occurred during the observed time period and accounted for various dimensions: number, length, type, and sequence of placements; timing of transitions; and total time in out-of-home care. The Placement History Chart is an effective tool for placing foster care experiences within a broader developmental context. As such, the Placement History Chart can be a valuable research tool for understanding various dimensions and variations of placement transitions among foster children by capturing sequences and cumulative risks over time. Furthermore, this chart can facilitate the development of intervention programs that are developmentally sensitive and effectively address particularly vulnerable subpopulations of foster children.

  10. Inferior patellar pole fragmentation in children: just a normal variant?

    Energy Technology Data Exchange (ETDEWEB)

    Kan, J.H.; Vogelius, Esben S.; Orth, Robert C.; Guillerman, R.P.; Jadhav, Siddharth P. [Texas Children' s Hospital, E.B. Singleton Pediatric Radiology, Houston, TX (United States)

    2015-06-15

    Fragmentary ossification of the inferior patella is often dismissed as a normal variant in children younger than 10 years of age. The purpose of this study was to determine whether fragmentary inferior patellar pole ossification is a normal variant or is associated with symptoms or signs of pathology using MRI and clinical exam findings as reference. A retrospective review was performed on 150 patients ages 5-10 years who underwent 164 knee radiography and MRI exams (45.1% male, mean age: 7.8 years). The presence or absence of inferior patellar pole fragmentation on radiography was correlated with the presence or absence of edema-like signal on MR images. Clinical notes were reviewed for the presence of symptoms or signs referable to the inferior patellar pole. These data were compared with a 1:1 age- and sex-matched control group without inferior pole fragmentation. Statistical analysis was performed using two-tailed t-tests. Forty of 164 (24.4%) knee radiographs showed fragmentary ossification of the inferior patella. Of these 40 knees, 62.5% (25/40) had edema-like signal of the inferior patellar bone marrow compared with 7.5% (3/40) of controls (P = 0.035). Patients with fragmentary ossification at the inferior patella had a significantly higher incidence of documented focal inferior patellar pain compared with controls (20% vs. 2.5%, P = 0.015). Inferior patellar pole fragmentation in children 5 to 10 years of age may be associated with localized symptoms and bone marrow edema-like signal and should not be routinely dismissed as a normal variant of ossification. (orig.)

  11. Bycatch in the Maldivian pole-and-line tuna fishery.

    Science.gov (United States)

    Miller, Kelsey I; Nadheeh, Ibrahim; Jauharee, A Riyaz; Anderson, R Charles; Adam, M Shiham

    2017-01-01

    Tropical tuna fisheries are among the largest worldwide, with some having significant bycatch issues. However, pole-and-line tuna fisheries are widely believed to have low bycatch rates, although these have rarely been quantified. The Maldives has an important pole-and-line fishery, targeting skipjack tuna (Katsuwonus pelamis). In the Maldives, 106 pole-and-line tuna fishing days were observed between August 2014 and November 2015. During 161 fishing events, tuna catches amounted to 147 t: 72% by weight was skipjack, 25% yellowfin tuna (Thunnus albacares) and 3% other tunas. Bycatch (all non-tuna species caught plus all tuna discards) amounted to 951 kg (0.65% of total tuna catch). Most of the bycatch (95%) was utilized, and some bycatch was released alive, so dead discards were particularly low (0.02% of total tuna catch, or 22 kg per 100 t). Rainbow runner (Elagatis bipinnulata) and dolphinfish (Coryphaena hippurus) together constituted 93% of the bycatch. Live releases included small numbers of silky sharks (Carcharhinus falciformis) and seabirds (noddies, Anous tenuirostris and A. stolidus). Pole-and-line tuna fishing was conducted on free schools and schools associated with various objects (Maldivian anchored fish aggregating devices [aFADs], drifting FADs from western Indian Ocean purse seine fisheries, other drifting objects and seamounts). Free school catches typically included a high proportion of large skipjack and significantly less bycatch. Associated schools produced more variable tuna catches and higher bycatch rates. Fishing trips in the south had significantly lower bycatch rates than those in the north. This study is the first to quantify bycatch rates in the Maldives pole-and-line tuna fishery and the influence of school association on catch composition. Ratio estimator methods suggest roughly 552.6 t of bycatch and 27.9 t of discards are caught annually in the fishery (based on 2015 national catch), much less than other Indian Ocean tuna

  12. Acute effects of flexible pole exercise on heart rate dynamics.

    Science.gov (United States)

    de Oliveira, Letícia Santana; Moreira, Patrícia S; Antonio, Ana M; Cardoso, Marco A; de Abreu, Luiz Carlos; Navega, Marcelo T; Raimundo, Rodrigo D; Valenti, Vitor E

    2015-01-01

    Exercise with flexible poles provides fast eccentric and concentric muscle contractions. Although the literature reports significant muscle chain activity during this exercise, it is not clear if a single bout of exercise induces cardiac changes. In this study we assessed the acute effects of flexible pole exercise on cardiac autonomic regulation. The study was performed on 22 women between 18 and 26 years old. We assessed heart rate variability (HRV) in the time (SDNN, RMSSD and pNN50) and frequency (HF, LF and LF/HF ratio) domains and geometric indices of HRV (RRTri, TINN, SD1, SD2 and SD1/SD2 ratio). The subjects remained at rest for 10 min and then performed the exercises with the flexible poles. Immediately after the exercise protocol, the volunteers remained seated at rest for 60 min and HRV was analyzed. We observed no significant changes in time domain (SDNN: p=0.72; RMSSD: p=0.94 and pNN50: p=0.92) or frequency domain indices (LF [nu]: p=0.98; LF [ms(2)]: p=0.72; HF [nu]: p=0.98; HF [ms(2)]: p=0.82 and LF/HF ratio: p=0.7) or in geometric indices (RRTri: p=0.54; TINN: p=0.77; SD1: p=0.94; SD2: p=0.67 and SD/SD2: p=0.42) before and after a single bout of flexible pole exercise. A single bout of flexible pole exercise did not induce significant changes in cardiac autonomic regulation in healthy women. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  13. Optimal Trajectories Generation in Robotic Fiber Placement Systems

    Science.gov (United States)

    Gao, Jiuchun; Pashkevich, Anatol; Caro, Stéphane

    2017-06-01

    The paper proposes a methodology for optimal trajectories generation in robotic fiber placement systems. A strategy to tune the parameters of the optimization algorithm at hand is also introduced. The presented technique transforms the original continuous problem into a discrete one where the time-optimal motions are generated by using dynamic programming. The developed strategy for the optimization algorithm tuning allows essentially reducing the computing time and obtaining trajectories satisfying industrial constraints. Feasibilities and advantages of the proposed methodology are confirmed by an application example.

  14. Mitigating HPA Axis Dysregulation Associated With Placement Changes in Foster Care

    Science.gov (United States)

    Fisher, Philip A.; Van Ryzin, Mark J.; Gunnar, Megan R.

    2012-01-01

    Summary Maltreated foster children often exhibit alterations in diurnal hypothalamic-pituitary-adrenal (HPA) axis activity that are characterized by lower cortisol levels upon waking and smaller declines in morning-to-evening cortisol levels. Previous research has shown that this dysregulated pattern is associated with high caregiver stress levels over the course of foster care placements. In contrast, therapeutic interventions that emphasize consistent and responsive caregiving have been associated with more regulated cortisol rhythms. In this paper, two related issues were explored: whether placement changes (i.e., moving between foster homes or from a foster home to a permanent placement) were associated with more blunted daily cortisol rhythms and whether a caregiver-based intervention exerted a protective effect in this context. Because the intervention program has components specifically designed to prepare foster children for placement changes and to maintain consistent parenting techniques despite them, a prevention effect on HPA axis dysregulation during placement changes was hypothesized. The results of linear mixed modeling analyses showed that placement changes predicted dysregulation in cortisol rhythms in the regular foster care group but not in the intervention foster care group. These findings are discussed in terms of implications for child welfare policy and practice. PMID:20888698

  15. Wire inhomogeneity detector having a core with opposing pole pieces and guide pieces adjacent the opposing pole pieces

    International Nuclear Information System (INIS)

    Gibson, G.H.; Smits, R.G.; Eberhard, P.H.

    1989-01-01

    This patent describes a wire inhomogeneity detector assembly for detecting changes in the conductive properties of a wire as the wire is passed therethrough. It comprises: a coil assembly through which a wire containing conductive material is adapted to be pressed in a direction substantially perpendicular to a longitudinal axis of the coil assembly. The coil assembly comprising a single ferrite core having a pair of opposing pole pieces between which are an associated conductive wire to be tested is adapted to be passed, each of the pole pieces having a coil wound therearound. The coil assembly including a guide-block consisting of a pair of guide pieces mounted adjacent to ends of the opposing pole pieces for guiding an associated conductive wire between the pole pieces and for reducing stray magnetic field lines. The guide pieces being positioned closely adjacent an associated conductive wire passing therebetween; an impedance bridge adjusted to an null balance point operatively connected to the coil assembly which measures the impedance of the coil assembly and is unbalanced by changes in eddy currents generated in the coil assembly; and a filter detector alarm assembly operatively connected to an output of the impedance bridge. The filter detector alarm assembly including an input bandpass filter detector alarm assembly including an input bandpass filter operatively connected to a differential comparator, the output of which triggers an alarm

  16. Repair of impact damaged utility poles with fiber reinforced polymers (FRP), phase II : [summary].

    Science.gov (United States)

    2015-04-01

    The aluminum and steel utility poles which support traffic signals, lighting, or mast-arm signs : are vulnerable to collisions from vehicles because of proximity to roadways. Removing these : poles for repair is costly and time-consuming, and removal...

  17. Gastrostomy Tube Placement Without Nasogastric Tube: A Retrospective Evaluation in 85 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Heberlein, Wolf E., E-mail: weheberlein@uams.edu; Goodwin, Whitney J.; Wood, Clint E.; Yousaf, Muhammad; Culp, William C. [University of Arkansas for Medical Sciences, Department of Radiology (United States)

    2012-12-15

    Purpose: Our study evaluated techniques for percutaneous gastrostomy (G)-tube placement without the use of a nasogastric (NG) tube. Instead, direct puncture of a physiologic air bubble or effervescent-enhanced gastric bubble distention was performed in patients with upper digestive tract obstruction (UDTO) or psychological objections to NG tubes. Materials and Methods: A total of 886 patients underwent G-tube placement in our department during a period of 7 years. We present our series of 85 (9.6%) consecutive patients who underwent percutaneous G-tube placement without use of an NG tube. Results: Of these 85 patients, fluoroscopic guided access was attempted by direct puncture of a physiologically present gastric air bubble in 24 (28%) cases. Puncture of an effervescent-induced large gastric air bubble was performed in 61 (72%) patients. Altogether, 82 (97%) of 85 G tubes were successfully placed in this fashion. The three failures comprised refusal of effervescent, vomiting of effervescent, and one initial tube misplacement when a deviation from our standard technique occurred. Conclusion: The described techniques compare favorably with published large series on G-tube placement with an NG tube in place. The techniques are especially suited for patients with UDTO due to head, neck, or esophageal malignancies, but they should be considered as an alternative in all patients. Direct puncture of effervescent-enhanced gastric bubble distention is a safe, patient-friendly and effective technique.

  18. [The splenic inferior pole of rats and hyperbaric oxygen].

    Science.gov (United States)

    Paulo, Isabel Cristina Andreatta Lemos; Paulo, Danilo Nagib Salomão; Ferrari, Thiago Antunes; Azeredo, Thiago Caetano Valadão de; Silva, Alcino Lázaro da

    2008-01-01

    To study the functional and morphological features of the lower pole of the spleen in rats submitted, or not, to postoperative hyperbaric oxygen therapy. Seventy-nine Wistar rats, weighing 248.7 +/- 27 g, divided into two groups [group A - simulation (n=40), group B - lower pole (n=39)] underwent surgery and were subdivided into two groups: 11 and 70 postoperative days. Each subgroup was subdivided into animals not treated (nt) (A11nt, n=10; B11nt, n=13; A70nt, n=10; B70nt, n=9) and treated with hyperbaric oxygen (t) (A11t, n=10; B11t, n=9; A70t, n=10; B70t, n=8). Blood was collected for measurement of lipids and immunoglobulins, platelet and Howell-Jolly body count before and after surgery. The spleen and lower pole were removed for histology. There was an increase of total cholesterol (p=0.002), VLDL-cholesterol and triglycerides (p=0.003) and of LDL-cholesterol (p=0.013) in subgroup B11nt, and no alterations were observed in the other subgroups. IgM decreased in subgroups B11t (p=0.007), B11nt (p=0.0000), B70nt (p=0.0005), B70t (p=0.02), and no change was observed in the simulation group. The number of platelets increased in subgroups B11nt (p=0.002) and B11t (p=0.01) and remained unchanged in the other subgroups. Howell-Jolly bodies were less numerous in subgroup B70nt than in subgroup B11nt (p=0.019). Lower pole viability was better in subgroup B11t than in B11nt and in subgroup B70 than in B11, and did not differ between subgroups B70t and B70nt. Function and viability of the remaining lower pole improved during the late postoperative period. Viability and function of the lower pole were better during the early but not during the late postoperative period, in animals submitted to hyperbaric oxygen therapy.

  19. Manchester Clinical Placement Index (MCPI): Conditions for medical students’ learning in hospital and community placements

    NARCIS (Netherlands)

    Dornan, Tim; Muijtjens, Arno; Graham, Jennifer; Scherpbier, Albert; Boshuizen, Els

    2012-01-01

    Dornan, T., Muijtjens, A., Graham, J., Scherpbier, A., & Boshuizen, H. P. A. (2012). Manchester Clinical Placement Index (MCPI): Conditions for medical students’ learning in hospital and community placements. Advances in Health Sciences Education, 17, 703-716. doi:10.1007/s10459-10011-19344-x

  20. Finite element modeling of small-scale tapered wood-laminated composite poles with biomimicry features

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse

    2008-01-01

    Tapered composite poles with biomimicry features as in bamboo are a new generation of wood laminated composite poles that may some day be considered as an alternative to solid wood poles that are widely used in the transmission and telecommunication fields. Five finite element models were developed with ANSYS to predict and assess the performance of five types of...

  1. The Neville-Aitken formula for rational interpolants with prescribed poles

    Science.gov (United States)

    Carstensen, C.; Mühlbach, G.

    1992-12-01

    Using a polynomial description of rational interpolation with prescribed poles a simple purely algebraic proof of a Neville-Aitken recurrence formula for rational interpolants with prescribed poles is presented. It is used to compute the general Cauchy-Vandermonde determinant explicitly in terms of the nodes and poles involved.

  2. Mechanical properties of small-scale laminated wood composite poles: effects of taper and webs

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse

    2006-01-01

    Laminated hollow wood composite poles represent an efficient utilization of the timber resource and a promising alternative for solid poles that are commonly used in the power transmission and telecommunication lines. The objective of this study was to improve the performance of composite poles by introducing the bio-mimicry concept into the design of hollow wood...

  3. [Determinants of urgency of nursing home placement].

    Science.gov (United States)

    Kishida, Kensaku; Tanizaki, Shizuko

    2008-05-01

    The aim of this paper was to identify factors affecting the urgency of nursing home placement after introduction of public long-term care insurance. The subjects were families including at least one disabled elderly person and one another family member in two cities in Chugoku Prefecture. The measure of the urgency of placement was 0 if the family did not submit any application for placement, 1 if the care managers judged that the elderly person should enter in the future when she/he really needs placement, 2 if the care managers judged that she/he might be able to wait for a short while, and 3 if the care managers judged that she/he should enter as early as possible. Our estimation method was by ordered logit model. The dependent variable was the measure of the urgency and the independent variables were several attributes of the families. In the estimation, we considered the possibility that the coefficients depend on categories of dependent variable. We obtained data for 146 waiting families and 494 others (total 640). There were differences in the urgency of placement among waiting elderly as follows "she/he should enter as early as possible" (28.8%); "she/he can wait for a while" (32.2%), "she/he should enter in the future when she/he really needs placement" (39.0%). The results of multivariate analyses showed that the urgency of placement correlated significantly with the severity of the elderly persons disabilities, the number of primary caregivers' self-symptoms, the family members' negative attitude toward caregiving, residing in city A, not having one's own house and limited use of short-stay facilities due to the circumstances of the providers. When judging the urgency of placement, we should consider not only whether the applicant has submitted a request for a nursing home or not, but also differences among the waiting families. The urgency of placement correlates significantly with severity of disability of the elderly person, the number of primary

  4. Parallel algorithms for placement and routing in VLSI design. Ph.D. Thesis

    Science.gov (United States)

    Brouwer, Randall Jay

    1991-01-01

    The computational requirements for high quality synthesis, analysis, and verification of very large scale integration (VLSI) designs have rapidly increased with the fast growing complexity of these designs. Research in the past has focused on the development of heuristic algorithms, special purpose hardware accelerators, or parallel algorithms for the numerous design tasks to decrease the time required for solution. Two new parallel algorithms are proposed for two VLSI synthesis tasks, standard cell placement and global routing. The first algorithm, a parallel algorithm for global routing, uses hierarchical techniques to decompose the routing problem into independent routing subproblems that are solved in parallel. Results are then presented which compare the routing quality to the results of other published global routers and which evaluate the speedups attained. The second algorithm, a parallel algorithm for cell placement and global routing, hierarchically integrates a quadrisection placement algorithm, a bisection placement algorithm, and the previous global routing algorithm. Unique partitioning techniques are used to decompose the various stages of the algorithm into independent tasks which can be evaluated in parallel. Finally, results are presented which evaluate the various algorithm alternatives and compare the algorithm performance to other placement programs. Measurements are presented on the parallel speedups available.

  5. Internal fixation of displaced inferior pole of the patella fractures using vertical wiring augmented with Krachow suturing.

    Science.gov (United States)

    Oh, Hyoung-Keun; Choo, Suk-Kyu; Kim, Ji-Wan; Lee, Mark

    2015-12-01

    We present the surgical technique of separate vertical wiring for displaced inferior pole fractures of the patella combined with Krachow suture and report the surgical outcomes. Between September 2007 to May 2012, 11 consecutive patients (mean age, 54.6 years) with inferior pole fractures of the patella (AO/OTA 34-A1) were retrospectively enrolled in this study. Through longitudinal incision, all patients underwent open reduction and internal fixation by separate vertical wiring combined with Krackow suture. The range of motion, loss of fixation, and Bostman score were primary outcome measures. The union time was 10 weeks after surgery on average (range: 8-12). No patient had nonunion, loss of reduction and wire breakage. There was no case of wound problem and irritation from the implant. At final follow-up, the average range of motion arc was 129.4° (range: 120-140). The mean Bostman score at last follow-up was 29.6 points (range: 28-30) and graded excellent in all cases. Separate vertical wiring combined with Krackow suture for inferior pole fractures of the patella is a useful technique that is easy to perform and can provide stable fixation with excellent results in knee function. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. A new way of utilizing pole face windings and magnetic field corrections for independent tuning of betatron wave numbers and chromaticities in the CERN Proton Synchrotron

    CERN Document Server

    Gouiran, R

    1978-01-01

    Precise control of the quadrupole and sextupole components of the magnetic fields in focusing and defocusing sectors respectively was achieved by the combined use of pole-face and yoke windings with three separate power supplies synchronously programmed by a computer. Experience of this technique led to a new philosophy in the design of pole-face windings, in which they become an integral and active part of the magnet. With the arrangement described, focusing and guiding functions are partially separated and an old combined-function accelerator can be transformed effectively into a more flexible separate-function machine without any decrease in available straight- section space. (5 refs).

  7. Page placement policies for NUMA multiprocessors

    Energy Technology Data Exchange (ETDEWEB)

    LaRowe, R.P. Jr.; Ellis, C.S. (Dept. of Computer Science, Duke Univ., Durham, NC (US))

    1991-02-01

    In many parallel applications, the size of the program's data exceeds even the very large amount of main memory available on large-scale multiprocessors. Virtual memory, in the sense of a transparent management of the main/secondary memory hierarchy, is a natural solution. The replacement, fetch, and placement policies used in uniprocessor paging systems need to be reexamined in light of the differences in the behavior of parallel computations and in the memory architectures of multiprocessors. In this paper the authors investigate the impact of page placement in nonuniform memory access time (NUMA) shared memory MIMD machines. The authors experimentally evaluate several paging algorithms that incorporate different approaches to the placement issue. Under certain workload assumptions, the results show that placement algorithms that are strongly biased toward local frame allocations but are able to borrow remote frames can reduce the number of page faults over strictly local allocation. The increased cost of memory operations due to the extra remote accesses is more than compensated for by the savings resulting from the reduction in demand fetches, effectively reducing the computation completion time for these programs without having adverse effects on the performance of typical NUMA programs. The authors also discuss some early results obtained from an actual kernel implementation of one of the page placement algorithms.

  8. Claw-pole Synchronous Generator for Compressed Air Energy Storage

    Directory of Open Access Journals (Sweden)

    PAVEL Valentina

    2013-05-01

    Full Text Available This paper presents a claw-poles generator for compressed air energy storage systems. It is presented the structure of such a system used for compensating of the intermittency of a small wind energy system. For equipping of this system it is chosen the permanent magnet claw pole synchronous generator obtained by using ring NdFeB permanentmagnets instead of excitation coil. In such a way the complexity of the scheme is reduced and the generator become maintenance free. The new magnetic flux density in the air-gap is calculated by magneticreluctance method and by FEM method and the results are compared with measured values in the old and new generator.

  9. Study of recursive model for pole-zero cancellation circuit

    International Nuclear Information System (INIS)

    Zhou Jianbin; Zhou Wei; Hong Xu; Hu Yunchuan; Wan Xinfeng; Du Xin; Wang Renbo

    2014-01-01

    The output of charge sensitive amplifier (CSA) is a negative exponential signal with long decay time which will result in undershoot after C-R differentiator. Pole-zero cancellation (PZC) circuit is often applied to eliminate undershoot in many radiation detectors. However, it is difficult to use a zero created by PZC circuit to cancel a pole in CSA output signal accurately because of the influences of electronic components inherent error and environmental factors. A novel recursive model for PZC circuit is presented based on Kirchhoff's Current Law (KCL) in this paper. The model is established by numerical differentiation algorithm between the input and the output signal. Some simulation experiments for a negative exponential signal are carried out using Visual Basic for Application (VBA) program and a real x-ray signal is also tested. Simulated results show that the recursive model can reduce the time constant of input signal and eliminate undershoot. (authors)

  10. On the ultimate uncertainty of the top quark pole mass

    Energy Technology Data Exchange (ETDEWEB)

    Beneke, M. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Marquard, P. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Nason, P. [INFN, Sezione di Milano Bicocca (Italy); Steinhauser, M. [Karlsruher Institut fuer Technologie (Germany). Inst. fuer Theoretische Teilchenphysik

    2016-05-15

    We combine the known asymptotic behaviour of the QCD perturbation series expansion, which relates the pole mass of a heavy quark to the MS mass, with the exact series coefficients up to the four-loop order to determine the ultimate uncertainty of the top-quark pole mass due to the renormalon divergence. We perform extensive tests of our procedure by varying the number of colours and flavours, as well as the scale of the strong coupling and the MS mass, and conclude that this uncertainty is around 70 MeV. We further estimate the additional contribution to the mass relation from the five-loop correction and beyond to be 250 MeV.

  11. Development of a 10-m wedged-pole undulator

    International Nuclear Information System (INIS)

    Robinson, K.E.; Gottschalk, S.C.; James, F.E.; Quimby, D.C.; Slater, J.M.; Valla, A.S.

    1989-01-01

    A 10-m rare earth permanent magnet hybrid undulator called a near infrared scalable undulator system (NISUS) is under construction at Spectra Technology for use in the Boeing FEL program series. The design was optimized for operation at a 1-μm wavelength with the Boeing accelerator parameters. A remotely adjustable compound taper is utilized to achieve optimum startup gain and high saturated extraction. A summary of the relevant design parameters is listed. A major goal was to build NISUS from modules which would allow easy scaling to longer lengths without redesign. Prototype tests for verification of field strength and quality are complete as well as the delivery and installation of the initial 5 m. Improvements relative to the technology used in the earlier tapered hybrid undulator (THUNDER) are highlighted. The wedged-pole configuration is employed for a major increase in field strength while operating the poles farther from saturation

  12. Seasonal Evolution of Titan's Stratosphere Near the Poles

    Science.gov (United States)

    Coustenis, A.; Jennings, D. E.; Achterberg, R. K.; Bampasidis, G.; Nixon, C. A.; Lavvas, P.; Cottini, V.; Flasar, F. M.

    2018-02-01

    In this Letter, we report the monitoring of seasonal evolution near Titan’s poles. We find Titan’s south pole to exhibit since 2010 a strong temperature decrease and a dramatic enhancement of several trace species such as complex hydrocarbons and nitriles (HC3N and C6H6 in particular) previously only observed at high northern latitudes. This results from the seasonal change on Titan going from winter (2002) to summer (2017) in the north and, at the same time, the onset of winter in the south pole. During this transition period atmospheric components with longer chemical lifetimes linger in the north, undergoing slow photochemical destruction, while those with shorter lifetimes decrease and reappear in the south. An opposite effect was expected in the north, but not observed with certainty until now. We present here an analysis of high-resolution nadir spectra acquired by Cassini/Cassini Composite Infrared Spectrometer in the past years and describe the temperature and composition variations near Titan’s poles. From 2013 until 2016, the northern polar region has shown a temperature increase of 10 K, while the south has shown a more significant decrease (up to 25 K) in a similar period of time. While the south polar region has been continuously enhanced since about 2012, the chemical content in the north is finally showing a clear depletion for most molecules only since 2015. This is indicative of a non-symmetrical response to the seasons in Titan’s stratosphere that can set constraints on photochemical and GCM models.

  13. REGIONAL DEVELOPMENT THROUGH GROWTH AND URBAN DEVELOPMENT POLES IN ROMANIA

    Directory of Open Access Journals (Sweden)

    Stefana VARVARI

    2015-09-01

    Full Text Available In 2008 the Ministry of Development, Public Works and Housing (now the Ministry of Regional Development and Public Administration prepared the growth poles policy for Romania, establishing seven growth poles to be financed through the Regional Operational Programme 2007-1013, under the Priority Axis no. 1. For 2007-2013 there were also established 11 urban development poles. At present the Ministry is discussing with the European Commission the new Regional Operational Programme 2014-2020 in which the main policy lines regarding integrated territorial development also take into consideration the improvement of the quality of life and the “appearance” of towns and strengthening their role in the region. The main urban agglomerations (county seats are seen as development engines of the regions. The authors analyze the results obtained and the problems that appeared at regional level in what concerns the projects financed under Axis 1 of the ROP 2007-2013 by answering two main questions: did they really had the estimated impact on the growth and urban development poles and on the regions? and was there really an integrated approach used? Based on the results obtained from the analysis of the previous programming period the authors try to recommend some improvements that could be taken into consideration for the development of the Integrated urban development plans and priority projects that are going to be financed by ESI funds under Axis 4 of the new ROP 2014-2020, recommendations that could be taken into consideration when preparing the Guidelines for applicants for this axis.

  14. Tööpuudus 29%, palavikku pole / Rachel Donadio

    Index Scriptorium Estoniae

    Donadio, Rachel

    2010-01-01

    Lõuna-Hispaanias asuvas Cádizis on töötus 29%, ometi pole eurotsooni kõrgeim tööpuuduse määr tekitanud linnas sügavat sotsiaalset rahutust ega massilisi proteste, sest üsna kõrge elukvaliteedi tagavad töötutele kompleksne turvavõrk, mis koosneb varimajandusest, perekonna toetusest ja valitsuse toetusest

  15. Development of a superconducting claw-pole motor

    International Nuclear Information System (INIS)

    Watanabe, E.; Kikukawa, K.; Satoh, Y.; Torii, S.

    2008-01-01

    We have developed and produced a superconducting claw-pole motor for a trial purpose as a method to make the best use of the characteristic of superconductivity without collector rings or rotating superconducting coils that need to be cryocooled, and made some examinations. The unique feature in this motor is to have the mechanism that supports the reaction magnetic force generated in the axial direction

  16. Multiple mechanisms regulate NuMA dynamics at spindle poles.

    Science.gov (United States)

    Kisurina-Evgenieva, Olga; Mack, Gary; Du, Quansheng; Macara, Ian; Khodjakov, Alexey; Compton, Duane A

    2004-12-15

    The large coiled-coil protein NuMA plays an essential role in organizing microtubule minus ends at spindle poles in vertebrate cells. Here, we use both in vivo and in vitro methods to examine NuMA dynamics at mitotic spindle poles. Using fluorescence recovery after photobleaching, we show that an exogenously expressed green-fluorescent-protein/NuMA fusion undergoes continuous exchange between soluble and spindle-associated pools in living cells. These dynamics require cellular energy and display an average half-time for fluorescence recovery of approximately 3 minutes. To explore how NuMA dynamics at spindle poles is regulated, we exploited the association of NuMA with microtubule asters formed in mammalian mitotic extracts. Using a monoclonal antibody specific for human NuMA, we followed the fate of human NuMA associated with microtubule asters upon dilution with a hamster mitotic extract. Consistent with in vivo data, this assay shows that NuMA can be displaced from the core of pre-assembled asters into the soluble pool. The half-time of NuMA displacement from asters under these conditions is approximately 5 minutes. Using this assay, we show that protein kinase activity and the NuMA-binding protein LGN regulate the dynamic exchange of NuMA on microtubule asters. Thus, the dynamic properties of NuMA are regulated by multiple mechanisms including protein phosphorylation and binding to the LGN protein, and the rate of exchange between soluble and microtubule-associated pools suggests that NuMA associates with an insoluble matrix at spindle poles.

  17. Clusters of cyclones encircling Jupiter’s poles

    Science.gov (United States)

    Adriani, A.; Mura, A.; Orton, G.; Hansen, C.; Altieri, F.; Moriconi, M. L.; Rogers, J.; Eichstädt, G.; Momary, T.; Ingersoll, A. P.; Filacchione, G.; Sindoni, G.; Tabataba-Vakili, F.; Dinelli, B. M.; Fabiano, F.; Bolton, S. J.; Connerney, J. E. P.; Atreya, S. K.; Lunine, J. I.; Tosi, F.; Migliorini, A.; Grassi, D.; Piccioni, G.; Noschese, R.; Cicchetti, A.; Plainaki, C.; Olivieri, A.; O’Neill, M. E.; Turrini, D.; Stefani, S.; Sordini, R.; Amoroso, M.

    2018-03-01

    The familiar axisymmetric zones and belts that characterize Jupiter’s weather system at lower latitudes give way to pervasive cyclonic activity at higher latitudes. Two-dimensional turbulence in combination with the Coriolis β-effect (that is, the large meridionally varying Coriolis force on the giant planets of the Solar System) produces alternating zonal flows. The zonal flows weaken with rising latitude so that a transition between equatorial jets and polar turbulence on Jupiter can occur. Simulations with shallow-water models of giant planets support this transition by producing both alternating flows near the equator and circumpolar cyclones near the poles. Jovian polar regions are not visible from Earth owing to Jupiter’s low axial tilt, and were poorly characterized by previous missions because the trajectories of these missions did not venture far from Jupiter’s equatorial plane. Here we report that visible and infrared images obtained from above each pole by the Juno spacecraft during its first five orbits reveal persistent polygonal patterns of large cyclones. In the north, eight circumpolar cyclones are observed about a single polar cyclone; in the south, one polar cyclone is encircled by five circumpolar cyclones. Cyclonic circulation is established via time-lapse imagery obtained over intervals ranging from 20 minutes to 4 hours. Although migration of cyclones towards the pole might be expected as a consequence of the Coriolis β-effect, by which cyclonic vortices naturally drift towards the rotational pole, the configuration of the cyclones is without precedent on other planets (including Saturn’s polar hexagonal features). The manner in which the cyclones persist without merging and the process by which they evolve to their current configuration are unknown.

  18. Coherence between geophysical excitations and celestial pole offsets

    Czech Academy of Sciences Publication Activity Database

    Ron, Cyril; Vondrák, Jan

    2011-01-01

    Roč. 8, č. 3 (2011), s. 243-247 ISSN 1214-9705. [Czech-Polish Workshop on Recent Geodynamics of the Sudeten and Adjacent Areas. Třešť, 04.11.2010-06.11. 2010] R&D Projects: GA ČR GA205/08/0908 Institutional research plan: CEZ:AV0Z10030501 Keywords : geophysical excitations * celestial pole offsets * coherence Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 0.530, year: 2011

  19. Pole particles in Treder's tetrad theory

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, H.

    1977-01-01

    In the framework of Treder's tetrad theory of gravitation the interaction of pole-particles is considered in post-Newtonian approximation. The perihelion shift for the two-body problems is calculated for different matter-field-couplings. In general it depends not only from the sum of the masses but also from the reduced mass. The additional term is connected with the absorption of gravitation.

  20. Seasonal Evolution of Titan's South Pole 220 cm-1 Cloud

    Science.gov (United States)

    Jennings, Donald

    2016-06-01

    A cloud of ices that had been seen only in Titan's north during winter began to emerge at the south pole in 2012. Discovered by Voyager IRIS as an emission feature at 220 cm-1, the cloud has been studied extensively in both the north and south by Cassini CIRS. The spectral feature acts as a tracer of the seasonal changes at Titan's poles, relating to evolving composition, temperature structure and dynamics. Although candidates have been proposed, the chemical makeup of the cloud has never been identified. The cloud is composed of condensates derived from gases created at high altitude and transported to the cold, shadowed pole. In the north the cloud has diminished gradually over the Cassini mission as Titan has transitioned from winter to spring. The southern cloud, on the other hand, grew rapidly after 2012. By late 2014 it had developed a complex ring structure that was confined to latitudes poleward of 70°S within the deep temperature well that had formed at the south pole [1]. The location of the cloud coincides in latitude with the HCN cloud reported by ISS and VIMS [2,3]. CIRS also saw enhanced gas emissions at those latitudes [4]. When it first formed, the cloud was abundant at altitudes as high as 250 km, while later it was found mostly at 100-150 km, suggesting that the material that had been deposited from above had gathered at the lower altitudes. Radiance from the southern cloud increased until mid-2015 and since then has decreased. The cloud may be transitioning to the more uniform hood morphology familiar in the north. Taking the north and south together, by the end of the Cassini mission in 2017 we will have observed almost an entire seasonal cycle of the ice cloud.

  1. Pole mass, width, and propagators of unstable fermions

    International Nuclear Information System (INIS)

    Kniehl, B.A.; Sirlin, A.

    2008-01-01

    The concepts of pole mass and width are extended to unstable fermions in the general framework of parity-nonconserving gauge theories, such as the Standard Model. In contrast with the conventional on-shell definitions, these concepts are gauge independent and avoid severe unphysical singularities, properties of great importance since most fundamental fermions in nature are unstable particles. General expressions for the unrenormalized and renormalized dressed propagators of unstable fermions and their field-renormalization constants are presented. (orig.)

  2. Performance study of quadrupole with broken line profile pole tip

    International Nuclear Information System (INIS)

    Fan Mingwu; Zhang Tianjue; Chu Chengjie

    1997-01-01

    Most of quadrupole used for beam focusing possess hyperbola profile tip. To simplify machining processes and ensure the assembling accuracy, a broken line profile pole tip is adapted instead of hyperbola. The results of the magnetic field simulation codes and the tests show the good quality field generated by such configuration: not only more uniform field gradient, but also field more concentrated at useful area. These types of quadrupole are used at CYCIAE-30 cyclotron and HI-13 tandem transportation lines

  3. Edgar Savisaar : BRS pole piisavalt investeerinud / Raigo Neudorf

    Index Scriptorium Estoniae

    Neudorf, Raigo

    2006-01-01

    Majandus- ja kommunikatsiooniminister on rahul, et riigi ja BRS-iga saavutati kokkulepe ettevõtte aktsiate tagasiostuks, kuid leiab, et BRS pole täitnud võetud investeerimiskohustusi ning seega peab järgnevatel aastatel suunama ettevõtte kaasajastamisse miljardeid kroone. Vt. samas: Jüri Käo: investeeringute kogumaht ületas nõutu; Savisaar: Jüri Käo ajab pada; Pingelised läbirääkimised BRS-iga

  4. Background Studies for Acoustic Neutrino Detection at the South Pole

    Science.gov (United States)

    Abbasi, R.; Abdou, Y.; Abu-Zayyad, T.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Andeen, K.; Auffenberg, J.; Bai, X.; Baker, M.; hide

    2012-01-01

    The detection of acoustic signals from ultra-high energy neutrino interactions is a promising method. to measure the flux of cosmogenic neutrinos expected on Earth. The energy threshold for this process depends strongly on the absolute noise level in the target material. The South Pole Acoustic Test Setup (SPATS). deployed in the upper part of four boreholes of the IceCube Neutrino Observatory, has monitored the noise in Antarctic ice at the geographic South Pole for more than two years down to 500 m depth. The noise is very stable and Gaussian distributed, Lacking an in situ calibration up to now, laboratory measurements have been used to estimate the absolute noise level in the 10-50 kHz frequency range to be smaller than 20 mPa. Using a threshold trigger. sensors of the South Pole Acoustic Test Setup registered acoustic events in the IceCube detector volume and its vicinity. Acoustic signals from refreezing IceCube holes and from anthropogenic sources have been used to test the localization of acoustic events. An upper limit on the neutrino flux at energies E(sub v) > 10(exp 11) GeV is derived from acoustic data taken over eight months.

  5. THE SUSTAINABLE DEVELOPMENT OF THE BRASOV GROWTH POLE

    Directory of Open Access Journals (Sweden)

    Aida CATANA

    2016-12-01

    Full Text Available The demographic dynamics analysed in the context of the relationship between economic development and social inclusion presents an image of the sustainable development of a community as well as the manner how the financial resources have been used. With an allocation of 74.3 million euro in the programming period 2007-2013, the Brasov Growth Pole has pursued the contribution to the achievement of sustainable development since 2005 by the participation in the Agenda 21. The implementation of projects with European financing in areas such as transport, social and educational infrastructure or tourism have generated changes/demographic movements, which this paper proposes to present. The evolution of the stable population, its dynamics at the level of each locality that is part of the Brasov growth pole as well as the dynamics of the number of employees or the development of the unemployment rate are presented by the cluster analysis. The effects of the European financing obtained from Regional Operational Programme 2007-2013 are thus reflected in the sustainable development of the Brasov growth pole from the point of view of the dynamics of the population

  6. Factorization and resummation for collinear poles in QCD amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Lance J.; Magnea, Lorenzo; Sterman, George

    2008-05-28

    We study the origin of subleading soft and collinear poles of form factors and amplitudes in dimensionally-regulated massless gauge theories. In the case of form factors of fundamental fields, these poles originate from a single function of the coupling, denoted G({alpha}{sub s}), depending on both the spin and gauge quantum numbers of the field. We relate G({alpha}{sub s}) to gauge-theory matrix elements involving the gluon field strength. We then show that G({alpha}{sub s}) is the sum of three terms: a universal eikonal anomalous dimension, a universal non-eikonal contribution, given by the coefficient B{sub {delta}}({alpha}{sub s}) of {delta}(1-z) in the collinear evolution kernel, and a process-dependent short-distance coefficient function, which does not contribute to infrared poles. Using general results on the factorization of soft and collinear singularities in fixed-angle massless gauge theory amplitudes, we conclude that all such singularities are captured by the eikonal approximation, supplemented only by the knowledge of B{sub {delta}}({alpha}{sub s}). We explore the consequences of our results for conformal gauge theories, where in particular we find a simple exact relation between the form factor and the cusp anomalous dimension.

  7. Automatic Pole and Q-Value Extraction for RF Structures

    Energy Technology Data Exchange (ETDEWEB)

    C. Potratz, H.-W. Glock, U. van Rienen, F. Marhauser

    2011-09-01

    The experimental characterization of RF structures like accelerating cavities often demands for measuring resonant frequencies of Eigenmodes and corresponding (loaded) Q-values over a wide spectral range. A common procedure to determine the Q-values is the -3dB method, which works well for isolated poles, but may not be applicable directly in case of multiple poles residing in close proximity (e.g. for adjacent transverse modes differing by polarization). Although alternative methods may be used in such cases, this often comes at the expense of inherent systematic errors. We have developed an automation algorithm, which not only speeds up the measurement time significantly, but is also able to extract Eigenfrequencies and Q-values both for well isolated and overlapping poles. At the same time the measurement accuracy may be improved as a major benefit. To utilize this procedure merely complex scattering parameters have to be recorded for the spectral range of interest. In this paper we present the proposed algorithm applied to experimental data recorded for superconducting higher-order-mode damped multi-cell cavities as an application of high importance.

  8. Management of lower pole nephrolithiasis: a critical analysis.

    Science.gov (United States)

    Lingeman, J E; Siegel, Y I; Steele, B; Nyhuis, A W; Woods, J R

    1994-03-01

    The results of extracorporeal shock wave lithotripsy (ESWL*) and percutaneous nephrostolithotomy for the treatment of lower pole nephrolithiasis were examined in 32 consecutive patients undergoing percutaneous nephrostolithotomy at the Methodist Hospital of Indiana and through meta-analysis of publications providing adequate stratification of treatment results. Of 101 cases managed with percutaneous nephrostolithotomy 91 (90%) were stone-free, a result significantly better than that achieved with ESWL (1,733 of 2,927 stone-free, 59%). Stone-free rates with percutaneous nephrostolithotomy were independent of stone burden, whereas stone-free rates with ESWL were inversely correlated to the stone burden treated. The morbidity of patients undergoing percutaneous nephrostolithotomy at our hospital was minimal, with a mean hospital stay of 4.7 +/- 2.8 days. No blood transfusions were required. All patients became stone-free. The percentage of urolithiasis patients with lower pole calculi is increasing. Because of the significantly greater efficacy of percutaneous nephrostolithotomy for lower pole calculi, particularly stones larger than 10 mm. in diameter, further consideration should be given to an initial approach with percutaneous nephrostolithotomy.

  9. Fluoroscopic placement of jejunal feeding tubes

    International Nuclear Information System (INIS)

    Hoffer, F.; Mandell, V.S.; Sandler, R.H.; Leichner, A.; Kaplan, L.C.; Haynie, M.

    1992-01-01

    Over a two-and-one-half year period, 50 children underwent placements of jejunal tubes through a nasal route (NJ, n=47) or through an existing gastrostomy site (GJ, n=119). There were four attempted placements (98% success rate). The NJ tubes remained in place an average of 13 days, and the GJ tubes remained in place an average of 37 days. Fluoroscopic time for placement of an NJ tube an averaged 6 min (29 cases) and for a GJ tube 8 minutes (91 cases). In spite of the limited retention time, fluoroscopic time, and availability of alternative methods, fluoroscopically placed jejunal feedings tubes are still playing an active role in this institution. (orig.)

  10. Bone grafting of the floor of the maxillary sinus for the placement of endosseous implants

    NARCIS (Netherlands)

    Raghoebar, GM; Vissink, A; Reintsema, H; Batenburg, RHK

    This study describes and evaluates a technique to augment the floor of the maxillary sinus and to widen the alveolar crest of the atrophic posterior maxilla with autogenous bone. The subjects were 43 patients whose maxillary alveolar crest was not high enough to permit reliable placement of

  11. 20 CFR 670.730 - What are the responsibilities of placement agencies?

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false What are the responsibilities of placement agencies? 670.730 Section 670.730 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF... techniques and job search strategies; (3) Identifying job leads or educational and training opportunities...

  12. 25 CFR 26.27 - What kind of Job Placement support services can I expect?

    Science.gov (United States)

    2010-04-01

    ... resume preparation, interview techniques, job retention, and related living skills. ... 25 Indians 1 2010-04-01 2010-04-01 false What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB...

  13. Spatial patterns of pollution associated with creosote treated poles in Mälardalen

    OpenAIRE

    Forselius, Ellen

    2015-01-01

    Creosote is a product name given to a mixture of several hundred compounds, which is often used to protect wooden poles from rot and insect damage, however it has also been linked to causing cancer in humans. Alternative materials for power poles include concrete, steel, composite and non-treated wooden poles. This report looks at Mälarenergi Elnät ABs 17,000 creosote coated poles and their patterns of pollution. GIS analyses in ArcGIS were used to evaluate which creosote poles are most criti...

  14. German causative events with placement verbs

    Directory of Open Access Journals (Sweden)

    De Knop Sabine

    2016-06-01

    Full Text Available Several studies have described the semantic uses of German posture verbs, but only few have dealt with German placement verbs. The present study wants to make up for this gap. Starting from a collection of examples from the core corpora of the Digitales Wörterbuch der Deutschen Sprache (DWDS and some former studies on posture verbs, it first describes the variety of the most common German placement verbs stellen (‘to put upright’, legen (‘to lay down’, setzen (‘to set’ and stecken (‘to stick’.

  15. POLE-LIKE OBJECT EXTRACTION FROM MOBILE LIDAR DATA

    Directory of Open Access Journals (Sweden)

    H. Zheng

    2016-06-01

    Full Text Available Object detection and recognition from LiDAR (Light Detection And Ranging data has been a research topic in the fields of photogrammetry and computer vision. Unlike point clouds collected in well-controlled indoor environments, point clouds in urban environments are more complex due to complexity of the real world. For example, trees sometimes close to signs or buildings, which will cause occlusions in the point clouds. Current object detection or reconstruction algorithms will have problems when recognizing objects with severe occlusions caused by trees etc. In this paper, a robust vegetation removal method and a DBSCAN based pole-like object detection method are proposed. Based on observation that major difference between vegetation and other rigid objects is their penetrability with respect to LiDAR, we introduce a local roughness measure to differentiate rigid objects from non-rigid ones (vegetation in this paper. First, a local sphere with a small radius is generated for each input point. Three principal components of the local sphere are then calculated, and a plane is determined. The roughness is obtained through calculating the standard deviation of distances from all inside points to the plane by a weighted summation of the normalized distances. The further the point to the plane, the smaller the weight is. Finally, a graph cuts based method is introduced to classify the input point sets into two groups. The data term is defined by the normalized roughness of the current point, and the smoothness term is defined by the normalized distance between the point and its nearest neighbour point. In terms of pole-like object detection, first, a uniformed 2D grid is generated through projecting all the points to the XY-plane. The seed points of the pole-like objects are obtained by determining the x and y coordinates by the centres of the highest density cells of the grid and the z coordinate by the mean height of the point sets of each object

  16. Noninvasive ventilation during percutaneous gastrostomy placement in Duchenne muscular dystrophy.

    Science.gov (United States)

    Pope, J F; Birnkrant, D J; Martin, J E; Repucci, A H

    1997-06-01

    Noninvasive positive pressure ventilation (NPPV) is used for respiratory support in a number of diseases causing acute or chronic respiratory failure. We describe a novel use of NPPV to provide respiratory support during sedation for percutaneous placement of a gastrostomy tube in a patient with Duchenne muscular dystrophy (DMD). The patient had severe respiratory insufficiency, progressive dysphagia, and undernutrition. In addition to the case in this report, we have used NPPV to provide respiratory support to DMD patients during five other gastrointestinal endoscopies without complication. The technique is highly labor intensive and requires physicians and respiratory therapists familiar with NPPV. The primary risk associated with this technique is lack of definitive airway protection during the procedure, which must be balanced against the risks of intubation in an anesthetized patient with neuromuscular disease. The potential benefit to selected patients is substantial, such as initiation of gastrostomy tube feeding in our patient, with subsequent improvement in his quality of life and nutritional status.

  17. Live imaging of spindle pole disorganization in docetaxel-treated multicolor cells

    International Nuclear Information System (INIS)

    Sakaushi, Shinji; Nishida, Kumi; Minamikawa, Harumi; Fukada, Takashi; Oka, Shigenori; Sugimoto, Kenji

    2007-01-01

    Treatment of cells with docetaxel at low concentrations induces aberrant bipolar spindles of which two centrosomes stay at only one pole, and also induces multipolar spindles. To gain insight into the relations between centrosome impairment and structural defects of the spindle, live-cell imaging was performed on a human MDA Auro/imp/H3 cell line in which centrosomes/mitotic spindles, nuclear membrane and chromatin were simultaneously visualized by fluorescent proteins. In the presence of docetaxel at IC 50 concentration, the centrosomes did not segregate, and multiple aster-like structures ectopically arose around the disappearing nuclear membrane. Those ectopic structures formed an acentrosomal pole opposing to the two-centrosomes-containing pole. In late metaphase, one pole often fragmented into multiple spindle poles, leading multipolar division. These results suggest that spindle pole fragility may be induced by centrosome impairment, and collapse of the pole may contribute to induction of aneuploid daughter cells

  18. Augmentation of residual alveolar bone height with tissue engineering for dental implant placement

    Directory of Open Access Journals (Sweden)

    S M Balaji

    2014-01-01

    Full Text Available The challenge of correcting deficient vertical alveolar height for dental implant placement has been there since dental implants came in to regular clinical placement. The ability of various methods to increase the residual alveolar height has met with varying results. The primary reason is that the techniques were not quite successful in maintaining the required residual alveolar height. Use of Bone Morphogentic Protein, especially rhBMP-2 has been met with high degree of success in deficient vertical alveolar height in a mandibular ridge. The demonstration of this using a case has been presented here.

  19. Predictable periimplant gingival esthetics: use of the natural tooth as a provisional following implant placement.

    Science.gov (United States)

    Margeas, Robert C

    2006-01-01

    Maintaining the interdental papilla and bone height following implant placement has been a challenge for the restorative dentist. Bone resorption following anterior tooth extraction is common and often compromises the esthetics of the final restoration. The tissue must be maintained during the surgical and healing phases to achieve an esthetic outcome. Using the patient's natural tooth as a provisional can help maintain the volume and support the papilla. This article describes a technique to achieve maximum esthetics and preservation of tissue following tooth extraction and implant placement. By using the patient's extracted natural tooth, the tissue should maintain itself with minimal recession. This will allow for a more esthetic outcome.

  20. Visual search strategies of soccer players executing a power vs. placement penalty kick.

    Directory of Open Access Journals (Sweden)

    Matthew A Timmis

    Full Text Available When taking a soccer penalty kick, there are two distinct kicking techniques that can be adopted; a 'power' penalty or a 'placement' penalty. The current study investigated how the type of penalty kick being taken affected the kicker's visual search strategy and where the ball hit the goal (end ball location.Wearing a portable eye tracker, 12 university footballers executed 2 power and placement penalty kicks, indoors, both with and without the presence of a goalkeeper. Video cameras were used to determine initial ball velocity and end ball location.When taking the power penalty, the football was kicked significantly harder and more centrally in the goal compared to the placement penalty. During the power penalty, players fixated on the football for longer and more often at the goalkeeper (and by implication the middle of the goal, whereas in the placement penalty, fixated longer at the goal, specifically the edges. Findings remained consistent irrespective of goalkeeper presence.Findings indicate differences in visual search strategy and end ball location as a function of type of penalty kick. When taking the placement penalty, players fixated and kicked the football to the edges of the goal in an attempt to direct the ball to an area that the goalkeeper would have difficulty reaching and saving. Fixating significantly longer on the football when taking the power compared to placement penalty indicates a greater importance of obtaining visual information from the football. This can be attributed to ensuring accurate foot-to-ball contact and subsequent generation of ball velocity. Aligning gaze and kicking the football centrally in the goal when executing the power compared to placement penalty may have been a strategy to reduce the risk of kicking wide of the goal altogether.

  1. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak [Department of Daignostic Radiology and Internal Medicine, Chonbuk National University Hospital, Chonju (Korea, Republic of); Han, Hyun Young [Department of Radiology, Eulgy University Hospital, Taejon (Korea, Republic of)

    2000-03-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  2. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  3. Noninvasive ventilation during gastrostomy tube placement in patients with severe duchenne muscular dystrophy: case reports and review of the literature.

    Science.gov (United States)

    Birnkrant, D J; Ferguson, R D; Martin, J E; Gordon, G J

    2006-02-01

    Individuals with Duchenne muscular dystrophy may benefit from gastrostomy tube feeding due to progressive dysphagia and malnutrition. However, due to their severely impaired pulmonary function, these individuals are at risk of severe complications when they are sedated or undergo anesthesia for the procedure. We previously described a technique of noninvasive positive pressure ventilation to provide respiratory support during gastrostomy tube placement in such patients, but this technique had risks and limitations. In this case report, we examine two alternative techniques we used to provide respiratory support successfully to patients with severe muscular dystrophy and malnutrition who underwent percutaneous endoscopic gastrostomy tube placement. We then review the literature and discuss the potential benefits, risks, and limitations of the above techniques and of other options for gastrostomy placement in people with severe muscular dystrophy. (c) 2005 Wiley-Liss, Inc.

  4. Predicting success on the Advanced Placement Biology Examination

    Science.gov (United States)

    Shepherd, Lesa Hanlin

    Four hundred sixty students in four public high schools were used as subjects to determine which of eleven academic and demographic factors studied were significant predictors of success for the Advanced Placement Biology Examination. Factors studied were attendance, class rank, gender, grade level at the time of the examination, grade point average, level of prerequisite biology course, number of Advanced Placement Examinations taken in the year prior to the Advanced Placement Biology Examination, number of Advanced Placement Examinations taken in the same year as the Advanced Placement Biology Examination, proposed major in college, race, and SAT mathematics, verbal, and combined score. Significant relationships were found to exist between the Advanced Placement Biology Examination score and attendance, class rank, gender, grade level at the time of the Advanced Placement Biology Examination, grade point average, number of Advanced Placement Examinations taken in the year prior to the Advanced Placement Biology Examination, number of Advanced Placement Examinations taken in the same year as the Advanced Placement Biology Examination, race, and SAT scores. Significant relationships were not found to exist between Advanced Placement Biology Examination score and level prerequisite biology course and Advanced Placement Biology Examination score and proposed major in college. A multiple regression showed the best combination of predictors to be attendance, SAT verbal score, and SAT mathematics score. Discriminant analysis showed the variables in this study to be good predictors of whether the student would pass the Advanced Placement Biology Examination (score a 3, 4, or 5) or fail the Advanced Placement Biology Examination (score a 1 or 2). These results demonstrated that significant predictors for the Advanced Placement Biology Examination do exist and can be used to assist in the prediction of scores, prediction of passing or failing, the identification of

  5. Source placement for equalization in small enclosures

    DEFF Research Database (Denmark)

    Stefanakis, Nick; Sarris, J.; Cambourakis, G.

    2008-01-01

    ) but not with those that will deteriorate it (the "undesired" modes). Simulation results in rectangular rooms and in a car cavity show the benefits of source placement in terms of reduced overall error and increased spatial robustness in the equalization process. Additional benefits, which can be derived by proper...

  6. Endoscopic stent placement throughout the gastrointestinal tract

    NARCIS (Netherlands)

    van den Berg, M.W.

    2014-01-01

    In this thesis we focussed our research on stent placement throughout the GI tract. In search for ideal stents for treatment of malignant oesophageal stenosis and gastric outlet obstruction we evaluated new stent designs in prospective cohort studies. Smaller research projects mainly aimed to

  7. Simple, quick, and efficient implant placement jig

    Directory of Open Access Journals (Sweden)

    Nikhil Narayan Pai

    2015-01-01

    Full Text Available Implants have become an inherent part of everyday orthodontic practice, but unlike prosthodontic implants, their placement and insertion into narrow interradicular spaces for orthodontic purposes remain a tricky and challenging part to most clinicians. An innovative and clinically useful method has been described here for safe and easy insertion of mini-implants.

  8. Weld Strength Assessment for Tape Placement

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Akkerman, Remko; Wijskamp, Sebastiaan; Kok, J.S.M.

    2010-01-01

    A mandrel peel set-up is developed to assess the peel fracture toughness of fibre reinforced thermoplastic tapes welded on a woven laminate using a laser-assisted tape placement robot. A comprehensive experimental programme was designed to investigate the influence of nip point temperature and

  9. Suboccipital neuropathy after bone conduction device placement

    NARCIS (Netherlands)

    Faber, H.T.; Ru, J.A. de

    2013-01-01

    OBJECTIVE: To describe the clinical characteristics of a 70-year-old female with occipital neuropathy following bone conduction device surgery. DESCRIPTION: A 65-year-old woman underwent bone conduction device placement surgery on the left temporal bone. Postoperatively she progressively developed

  10. Photoelectron Spectroscopy in Advanced Placement Chemistry

    Science.gov (United States)

    Benigna, James

    2014-01-01

    Photoelectron spectroscopy (PES) is a new addition to the Advanced Placement (AP) Chemistry curriculum. This article explains the rationale for its inclusion, an overview of how the PES instrument records data, how the data can be analyzed, and how to include PES data in the course. Sample assessment items and analysis are included, as well as…

  11. BIBLIOGRAPHIC GUIDE FOR ADVANCED PLACEMENT, LATIN.

    Science.gov (United States)

    BARRON, ROBERT; ROSELLE, LEONE

    LITERARY AND CRITICAL WORKS, REFERENCE BOOKS, PERIODICALS, RECORDS, FILMS, AND FILMSTRIPS DEALING WITH ROMAN LITERATURE, HISTORY, CIVILIZATION, MYTHOLOGY, AND LANGUAGE ARE INCLUDED IN THIS BIBLIOGRAPHY OF RECOMMENDED READING IN ENGLISH FOR ADVANCED PLACEMENT PROGRAMS IN LATIN. THE LIST IS DIVIDED INTO TWO $500 GROUPS, SO THAT FOR CONVENIENCE IN…

  12. 34 CFR 300.116 - Placements.

    Science.gov (United States)

    2010-07-01

    ... educational placement of a child with a disability, including a preschool child with a disability, each public... with a disability requires some other arrangement, the child is educated in the school that he or she... modifications in the general education curriculum. (Approved by the Office of Management and Budget under...

  13. Realistic Approach for Phasor Measurement Unit Placement

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Chen, Zhe; Thøgersen, Paul

    2015-01-01

    This paper presents a realistic cost-effectivemodel for optimal placement of phasor measurement units (PMUs) for complete observability of a power system considering practical cost implications. The proposed model considers hidden or otherwise unaccounted practical costs involved in PMU installat...

  14. Literary Archetypes. Advanced Placement English Curriculum Guide.

    Science.gov (United States)

    Anne Arundel County Public Schools, Annapolis, MD.

    Providing students with the opportunity to earn college credit while still in high school, the Advanced Placement English course described in this guide is designed to help students (1) want to choose from a wide range of literature for independent reading; (2) develop a critical awareness about literature; (3) recognize connections among works of…

  15. 5 CFR 359.702 - Placement rights.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Placement rights. 359.702 Section 359.702 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS REMOVAL FROM THE SENIOR... rights. (a) An appointee covered by this subpart is entitled to be placed in a vacant civil service...

  16. Flapless single-tooth immediate implant placement.

    Science.gov (United States)

    de Carvalho, Breno Carnevalli Franco; de Carvalho, Elaine Manso Oliveira Franco; Consani, Rafael Leonardo Xediek

    2013-01-01

    This 15-year prospective study evaluated the success rate and preservation of the gingival margin of single implants placed in a flapless procedure loaded immediately after extraction or after a healing period. Immediate flapless implant placement was performed in patients who fulfilled specified inclusion criteria. Implants were either immediately restored with a provisional crown or left unloaded (received healing abutment only). Implant success and gingival margin levels were evaluated after implant placement and after 1 to 15 years. A total of 305 healthy nonsmoking subjects (90 men, 215 women) were treated with 430 immediate implants during a 15-year period (December 1994 to December 2009) and monitored for 1 to 15 years. Two hundred seventy-five implants received an immediate provisional crown, and 155 received a healing abutment. The implant survival rate was 93.03% (± 3.74%). The immediate provisional helped to maintain the original gingival margin, although the implant survival rate was higher for implants that were not immediately restored (96.78%) than for the implants that were immediately restored with a provisional (90.9%). This 15-year prospective study showed a favorable implant success rate related to the flapless immediate implant placement protocol with healing abutment placement or an immediate provisional crown to replace a single missing tooth.

  17. Optimization of portal placement for endoscopic calcaneoplasty

    NARCIS (Netherlands)

    van Sterkenburg, Maayke N.; Groot, Minke; Sierevelt, Inger N.; Spennacchio, Pietro A.; Kerkhoffs, Gino M. M. J.; van Dijk, C. Niek

    2011-01-01

    The purpose of our study was to determine an anatomic landmark to help locate portals in endoscopic calcaneoplasty. The device for optimal portal placement (DOPP) was developed to measure the distance from the distal fibula tip to the calcaneus (DFC) in 28 volunteers to determine the location of the

  18. Delayed bracket placement in orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Chandra Wigati

    2008-12-01

    Full Text Available Background: Beside bracket position, the timing of bracket placement is one of the most essential in orthodontic treatment with fixed appliances. Even it seems simple the timing of bracket placement can be crucial and significantly influence the result of orthodontic treatment. However it is often found brackets are placed without complete understanding of its purpose and effects, which could be useless and even detrimental for the case. Purpose: The aim of this case report is to show that the timing of bracket placement could be different depending on the cases. Case: Five different cases are presented here with different timing of bracket placement. Case management: On these cases, brackets were placed on the upper arch first, on the lower arch first, or even only on some teeth first. Good and efficient orthodontic treatment results were achieved. Conclusion: For every orthodontic case, from the very beginning of treatment, bracket should be placed with the end result in mind. If brackets are correctly placed at a correct time, better treatment result could be achieved without unnecessary round tripping tooth movement.

  19. Relay Placement for FSO Multihop DF Systems With Link Obstacles and Infeasible Regions

    KAUST Repository

    Zhu, Bingcheng

    2015-05-19

    Optimal relay placement is studied for free-space optical multihop communication with link obstacles and infeasible regions. An optimal relay placement scheme is proposed to achieve the lowest outage probability, enable the links to bypass obstacles of various geometric shapes, and place the relay nodes in specified available regions. When the number of relay nodes is large, the searching space can grow exponentially, and thus, a grouping optimization technique is proposed to reduce the searching time. We numerically demonstrate that the grouping optimization can provide suboptimal solutions close to the optimal solutions, but the average searching time linearly grows with the number of relay nodes. Two useful theorems are presented to reveal insights into the optimal relay locations. Simulation results show that our proposed optimization framework can effectively provide desirable solution to the problem of optimal relay nodes placement. © 2015 IEEE.

  20. Zygomatic bone graft for oral-antral communication closure and implant placement.

    Science.gov (United States)

    Peñarrocha-Diago, Miguel; García, Berta; Gomez, Dolores; Balaguer, José

    2007-01-01

    The roots of molar and premolar maxillary teeth are often very close to the floor of the maxillary sinus. As a result, extraction of these teeth can leave an oral-antral communication or lead to a fistula that requires treatment. A woman with an oral-antral communication secondary to extraction of a maxillary molar is presented. The communication was closed by means of a bone graft harvested from the wall of the sinus (zygomatic bone). After 3 months, 2 dental implants were placed, one in the pterygoid area and the other with parasinusal angulation. Rehabilitation followed in the form of a screw-retained, fixed prosthesis 3 months after implant placement. There have been no complications after 1 year of follow-up. This surgical technique allowed closure of an oral-antral communication produced by molar extraction through placement of a zygomatic bone graft and subsequent placement of 2 dental implants.

  1. Contributions to the defocusing effect on pole figure measurements by X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Palacios G, J.; Salat F, R. S.; Jimenez J, A.; Kryshtab, T., E-mail: palacios@esfm.ipn.mx [Instituto Politecnico Nacional, Escuela Superior de Fisica y Matematicas, Av. IPN s/n, 07738 Mexico D. F. (Mexico)

    2015-07-01

    A simple method, considering a parallel beam approximation has been made to reproduce the main features of the defocusing effect, observed when pole figures are measured with the Schulz reflection technique using X-ray diffraction. A Lorentzian curve was used to approximate the primary beam profile. This method applied to low index reflections of copper and silver shows qualitatively and partially quantitatively, the extent the elongation of the ellipse resulting from the intersection of the beam with the tilted sample causes the defocusing effect. Differences observed experimentally are attributed mainly to the divergence of the beam, but also partially to the particular primary beam profile. Additionally, measurements with two different vertical heights of the receiving slit, i. e. the measured arch length of the Debye-Scherrer ring, indicate that this parameter plays no role in defocusing. (Author)

  2. All-Pole Recursive Digital Filters Design Based on Ultraspherical Polynomials

    Directory of Open Access Journals (Sweden)

    N. Stojanovic

    2014-09-01

    Full Text Available A simple method for approximation of all-pole recursive digital filters, directly in digital domain, is described. Transfer function of these filters, referred to as Ultraspherical filters, is controlled by order of the Ultraspherical polynomial, nu. Parameter nu, restricted to be a nonnegative real number (nu ≥ 0, controls ripple peaks in the passband of the magnitude response and enables a trade-off between the passband loss and the group delay response of the resulting filter. Chebyshev filters of the first and of the second kind, and also Legendre and Butterworth filters are shown to be special cases of these allpole recursive digital filters. Closed form equations for the computation of the filter coefficients are provided. The design technique is illustrated with examples.

  3. Comminuted inferior pole fracture of patella can be successfully treated with rim-plate-augmented separate vertical wiring.

    Science.gov (United States)

    Cho, Jae-Woo; Kim, Jinil; Cho, Won-Tae; Gujjar, Pranay H; Oh, Chang-Wug; Oh, Jong-Keon

    2018-02-01

    We present the surgical technique of rim-plate-augmented separate vertical wiring for comminuted inferior pole fracture of the patella and report the clinical outcomes. Between July 2013 and January 2016, 13 patients (7 male and 6 female) who were diagnosed with comminuted inferior pole fracture of the patella in preoperative computed tomography and underwent a minimum of 1 year of follow-up were enrolled in this study. Mean patient age was 57.7 years (range 28-72 years). All patients underwent open reduction and internal fixation by rim-plate-augmented separate vertical wiring. Bony union, complications, range of motion and Bostman score were the clinical outcomes. Bony union was achieved in all cases at an average of 10 weeks after surgery (range 8-12). There was no loss of reduction and fixative failure during follow-up. The average range of motion was 127° (range 120°-130°). The mean Bostman score at last follow-up was 29.6 points (range 27-30) and graded excellent in 12 patients. Rim-plate-augmented separate vertical wiring demonstrated secure fixation and favorable clinical outcomes. This study provides evidence for its effectiveness as a fixation method for treating displaced, comminuted inferior pole fracture of the patella.

  4. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  5. Why are mini-implants lost: The value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss. PMID:25741821

  6. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  7. DETECTION AND CLASSIFICATION OF POLE-LIKE OBJECTS FROM MOBILE MAPPING DATA

    Directory of Open Access Journals (Sweden)

    K. Fukano

    2015-08-01

    Full Text Available Laser scanners on a vehicle-based mobile mapping system can capture 3D point-clouds of roads and roadside objects. Since roadside objects have to be maintained periodically, their 3D models are useful for planning maintenance tasks. In our previous work, we proposed a method for detecting cylindrical poles and planar plates in a point-cloud. However, it is often required to further classify pole-like objects into utility poles, streetlights, traffic signals and signs, which are managed by different organizations. In addition, our previous method may fail to extract low pole-like objects, which are often observed in urban residential areas. In this paper, we propose new methods for extracting and classifying pole-like objects. In our method, we robustly extract a wide variety of poles by converting point-clouds into wireframe models and calculating cross-sections between wireframe models and horizontal cutting planes. For classifying pole-like objects, we subdivide a pole-like object into five subsets by extracting poles and planes, and calculate feature values of each subset. Then we apply a supervised machine learning method using feature variables of subsets. In our experiments, our method could achieve excellent results for detection and classification of pole-like objects.

  8. Immediate placement of endosseous implants into the extraction sockets

    OpenAIRE

    Vijay Ebenezer; K Balakrishnan; R Vigil Dev Asir; Banu Sragunar

    2015-01-01

    Implant by definition ?means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose.? The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone fo...

  9. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  10. New innovative method relating guided surgery to dental implant placement.

    Science.gov (United States)

    Fauroux, M-A; De Boutray, M; Malthiéry, E; Torres, J-H

    2018-02-20

    Companies selling dental implant guided systems mostly offer similar surgical guides. The purpose of this paper is to present an innovative-guided surgery system which originality lies in its guidance device, and to report the author's experience in using this system for dental implant surgery. Two parallel tubes on either side of the drilling axis guide the successive drills and the implant placement. As a result of the lateral guidance, there is no friction of the drills on the surgical guide, which would damage it or contaminate the drilling hole with particles torn out from the guide. No radiological guide is needed during the radiographic examination stage. No successive diameter reduction tubes are requested. This guide can be used for all brands of implants. In our experience, 67 implants (31 titanium and 36 zircon implants) were placed in 35 patients with guided surgery system. Multiple clinical cases were treated with this system: 'one-stage' or a 'two-stage' surgical protocol, with flap and flapless surgical techniques, and with delayed or immediate loading. Clinical cases treated revealed good implant placement with planning. The widely open design of this guide allows irrigation and practitioner's sight control under conditions comparable to those of operations performed without surgical guide. This dental implant guided system appears to be a significant advance in the field of implant surgical guides. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  11. Placement peripherally inserted central catheters (PICC): the upper arm approach

    International Nuclear Information System (INIS)

    Choo, In Wook; Choo, Sung Wook; Choi, Dong Il; Yoon, Jung Hwan; Hwang, Jae Woong; Lim, Jae Hoon; Andrews, James C.; Williams, David M.; Cho, Kyung J.

    1995-01-01

    To evaluate a recently developed technique to place a medium-duration (weeks to months) central venous access. Within three-year period, 635 patients were referred to interventional radiology suite for placement of peripherally inserted central catheter (PICC). Contrast medium was injected into the peripheral intravenous line and a puncture was made into the opacified vein near the junction of the middle and upper thirds of the upper arm, either the brachial or basilic vein under fluoroscopic guidance. A 5.5-French peel-away sheath was inserted into the vein and a 5-French silicone catheter was introduced with its distal tip to the junction of the right atrium and superior vena cava. Catheter placement was successful in all patients unless there was a central venous obstruction. Catheters were maintained from 2 days to 5 months with a mean of 3 weeks. Complications included infection requiring removal of the PICC in 16 patients (2.5%), acute thrombosis of the subclavian vein in 3 (0.5%). Occluded catheters in 4 patients were easily cleared with urokinase in place. The PICC system is an excellent option for medium-duration central venous access. Patients were able to carry on normal activities with the catheters in place

  12. Placement peripherally inserted central catheters (PICC): the upper arm approach

    Energy Technology Data Exchange (ETDEWEB)

    Choo, In Wook; Choo, Sung Wook; Choi, Dong Il; Yoon, Jung Hwan; Hwang, Jae Woong; Lim, Jae Hoon [Samsung Medical Center, Seoul (Korea, Republic of); Andrews, James C. [Mayo Clinic, Lansing (United States); Williams, David M.; Cho, Kyung J. [University of Michigan Hospital, Lansing (United States)

    1995-10-15

    To evaluate a recently developed technique to place a medium-duration (weeks to months) central venous access. Within three-year period, 635 patients were referred to interventional radiology suite for placement of peripherally inserted central catheter (PICC). Contrast medium was injected into the peripheral intravenous line and a puncture was made into the opacified vein near the junction of the middle and upper thirds of the upper arm, either the brachial or basilic vein under fluoroscopic guidance. A 5.5-French peel-away sheath was inserted into the vein and a 5-French silicone catheter was introduced with its distal tip to the junction of the right atrium and superior vena cava. Catheter placement was successful in all patients unless there was a central venous obstruction. Catheters were maintained from 2 days to 5 months with a mean of 3 weeks. Complications included infection requiring removal of the PICC in 16 patients (2.5%), acute thrombosis of the subclavian vein in 3 (0.5%). Occluded catheters in 4 patients were easily cleared with urokinase in place. The PICC system is an excellent option for medium-duration central venous access. Patients were able to carry on normal activities with the catheters in place.

  13. Determining the brand awareness of product placement in video games

    OpenAIRE

    Král, Marek

    2015-01-01

    This bachelor thesis focusses on the determination of the brand awareness of product placement in video games. The theoretical part includes information about marketing, product placement and video games. The practical part consists of evaluation of the market research about product placements in video games. Conclusion suggests the most important factors influencing the level brand awareness.

  14. Brand Placement and Consumer Choice: An in-Store Experiment

    Science.gov (United States)

    Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon

    2009-01-01

    An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior.…

  15. Optimal capacitor sizing and placement based on real time analysis ...

    African Journals Online (AJOL)

    In this paper, optimal capacitor sizing and placement method was used to improve energy efficiency. It involves the placement of capacitors in a specific location with suitable sizing based on the current load of the electrical system. The optimization is done in real time scenario where the sizing and placement of the ...

  16. 20 CFR 638.409 - Placement and job development.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Placement and job development. 638.409 Section 638.409 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR JOB CORPS... Placements in the Job Corps § 638.409 Placement and job development. The overall objective of all Job Corps...

  17. The use of ultrasound for peripheral IV placement by vascular access team nurses at a tertiary children's hospital.

    Science.gov (United States)

    Elkhunovich, Marsha; Barreras, Joanna; Bock Pinero, Valerie; Ziv, Nurit; Vaiyani, Aisha; Mailhot, Thomas

    2017-01-18

    Children receiving treatment in the hospital frequently require intravenous (IV) access. Placement of short peripheral catheters can be painful and challenging especially in those children who have difficult access. Many children's hospitals have teams of specialized vascular access nurses experienced in peripheral catheter insertion, and at times use vein visualization devices, including ultrasound (US), to assist in peripheral IV placement. Our objectives were to describe the prevalence and success rate of US-guided peripheral IV placement by vascular access team nurses at a single tertiary children's hospital. We retrospectively reviewed quality assurance data kept by our institution's vascular access team between February, 2014 and March, 2014. Data extracted included: age, gender, number of attempts, if difficult, if ultimately successful and modality used to aid IV placement. Descriptive statistics and chi-square tests were used to analyze and report data. There were 1111 patient-nurse encounters reported for peripheral IV placement over a six-week period, and a total of 1579 attempts. Ultimately 84% of the patients had successful IV placement. Overall, visualization and palpation was the most frequently used technique (50.1%), followed by near-infrared light (40.6%), US (8.0%), and transillumination (1.3%). The success rate of US (60% overall and 59.2% difficult) was not significantly different from other advanced visualization techniques. Vascular access team nurses use US infrequently for peripheral IV placement, including in children with difficult access. Methods to increase its skillful use in difficult access patients and improve successful IV placements should be explored.

  18. DISCOVERY OF FOG AT THE SOUTH POLE OF TITAN

    International Nuclear Information System (INIS)

    Brown, M. E.; Smith, A. L.; Chen, C.; Adamkovics, M.

    2009-01-01

    While Saturn's moon Titan appears to support an active methane hydrological cycle, no direct evidence for surface-atmosphere exchange has yet appeared. The indirect evidence, while compelling, could be misleading. It is possible, for example, that the identified lake features could be filled with ethane, an involatile long-term residue of atmospheric photolysis; the apparent stream and channel features could be ancient remnants of a previous climate; and the tropospheric methane clouds, while frequent, could cause no rain to reach the surface. We report here the detection of fog at the south pole of Titan during late summer using observations from the VIMS instrument on board the Cassini spacecraft. While terrestrial fog can form from a variety of causes, most of these processes are inoperable on Titan. Fog on Titan can only be caused by evaporation of nearly pure liquid methane; the detection of fog provides the first direct link between surface and atmospheric methane. Based on the detections presented here, liquid methane appears widespread at the south pole of Titan in late southern summer, and the hydrological cycle on Titan is currently active.

  19. Acoustic wave filter based on periodically poled lithium niobate.

    Science.gov (United States)

    Courjon, Emilie; Bassignot, Florent; Ulliac, Gwenn; Benchabane, Sarah; Ballandras, Sylvain

    2012-09-01

    Solutions for the development of compact RF passive transducers as an alternative to standard surface or bulk acoustic wave devices are receiving increasing interest. This article presents results on the development of an acoustic band-pass filter based on periodically poled ferroelectric domains in lithium niobate. The fabrication of periodically poled transducers (PPTs) operating in the range of 20 to 650 MHz has been achieved on 3-in (76.2-mm) 500-μm-thick wafers. This kind of transducer is able to excite elliptical as well as longitudinal modes, yielding phase velocities of about 3800 and 6500 ms(-1), respectively. A new type of acoustic band-pass filter is proposed, based on the use of PPTs instead of the SAWs excited by classical interdigital transducers. The design and the fabrication of such a filter are presented, as well as experimental measurements of its electrical response and transfer function. The feasibility of such a PPT-based filter is thereby demonstrated and the limitations of this method are discussed.

  20. Towards a research pole in photonics in Western Romania

    Science.gov (United States)

    Duma, Virgil-Florin; Negrutiu, Meda L.; Sinescu, Cosmin; Rominu, Mihai; Miutescu, Eftimie; Burlea, Amelia; Vlascici, Miomir; Gheorghiu, Nicolae; Cira, Octavian; Hutiu, Gheorghe; Mnerie, Corina; Demian, Dorin; Marcauteanu, Corina; Topala, Florin; Rolland, Jannick P.; Voiculescu, Ioana; Podoleanu, Adrian G.

    2014-07-01

    We present our efforts in establishing a Research Pole in Photonics in the future Arad-Timisoara metropolitan area projected to unite two major cities of Western Romania. Research objectives and related training activities of various institutions and groups that are involved are presented in their evolution during the last decade. The multi-disciplinary consortium consists principally of two universities, UAVA (Aurel Vlaicu University of Arad) and UMF (Victor Babes Medicine and Pharmacy University of Timisoara), but also of the Arad County Emergency University Hospital and several innovative SMEs, such as Bioclinica S.A. (the largest array of medical analysis labs in the region) and Inteliform S.R.L. (a competitive SME focused on mechatronics and mechanical engineering). A brief survey of the individual and joint projects of these institutions is presented, together with their teaching activities at graduate and undergraduate level. The research Pole collaborates in R&D, training and education in biomedical imaging with universities in USA and Europe. Collaborative activities, mainly on Optical Coherence Tomography (OCT) projects are presented in a multidisciplinary approach that includes optomechatronics, precision mechanics and optics, dentistry, medicine, and biology.

  1. Semantic representations in the temporal pole predict false memories.

    Science.gov (United States)

    Chadwick, Martin J; Anjum, Raeesa S; Kumaran, Dharshan; Schacter, Daniel L; Spiers, Hugo J; Hassabis, Demis

    2016-09-06

    Recent advances in neuroscience have given us unprecedented insight into the neural mechanisms of false memory, showing that artificial memories can be inserted into the memory cells of the hippocampus in a way that is indistinguishable from true memories. However, this alone is not enough to explain how false memories can arise naturally in the course of our daily lives. Cognitive psychology has demonstrated that many instances of false memory, both in the laboratory and the real world, can be attributed to semantic interference. Whereas previous studies have found that a diverse set of regions show some involvement in semantic false memory, none have revealed the nature of the semantic representations underpinning the phenomenon. Here we use fMRI with representational similarity analysis to search for a neural code consistent with semantic false memory. We find clear evidence that false memories emerge from a similarity-based neural code in the temporal pole, a region that has been called the "semantic hub" of the brain. We further show that each individual has a partially unique semantic code within the temporal pole, and this unique code can predict idiosyncratic patterns of memory errors. Finally, we show that the same neural code can also predict variation in true-memory performance, consistent with an adaptive perspective on false memory. Taken together, our findings reveal the underlying structure of neural representations of semantic knowledge, and how this semantic structure can both enhance and distort our memories.

  2. TiLoop® Bra mesh used for immediate breast reconstruction: comparison of retropectoral and subcutaneous implant placement in a prospective single-institution series.

    Science.gov (United States)

    Casella, Donato; Bernini, Marco; Bencini, Lapo; Roselli, Jenny; Lacaria, Maria Teresa; Martellucci, Jacopo; Banfi, Roberto; Calabrese, Claudio; Orzalesi, Lorenzo

    2014-01-01

    Immediate implant reconstruction after a conservative mastectomy is an attractive option made easier by prosthetic devices. Titanized polypropylene meshes are used as a hammock to cover the lower lateral implant pole. We conducted a prospective nonrandomized single-institution study of reconstructions using titanium-coated meshes either in a standard muscular mesh pocket or in a complete subcutaneous approach. The complete subcutaneous approach means to wrap an implant with titanized mesh in order to position the implant subcutaneously and spare muscles. Between November 2011 and January 2014, we performed immediate implant breast reconstructions after conservative mastectomies using TiLoop® Bra, either with the standard retropectoral or with a prepectoral approach. Selection criteria included only women with normal Body Mass Index (BMI), no large and very ptotic breasts, no history of smoking, no diabetes, and no previous radiotherapy. We analyzed short-term outcomes of such procedures and compared the outcomes to evaluate implant losses and surgical complications. A total of 73 mastectomies were performed. Group 1 comprised 29 women, 5 bilateral procedures, 34 reconstructions, using the standard muscular mesh pocket. Group 2 comprised 34 women, 5 bilateral procedures, 39 reconstructions with the prepectoral subcutaneous technique. Baseline and oncologic characteristics were homogeneous between the two groups. After a median follow-up period of 13 and 12 months, respectively, no implant losses were recorded in group 1, and one implant loss was recorded in group 2. We registered three surgical complications in group 1 and two surgical complications in group 2. Titanium-coated polypropylene meshes, as a tool for immediate definitive implant breast reconstruction, resulted as safe and effective in a short-term analysis, both for a retropectoral and a totally subcutaneous implant placement. Long-term results are forthcoming. A strict selection is mandatory to

  3. Planned and unplanned terminations of foster care placements in the Netherlands: Relationships with characteristics of foster children and foster placements

    NARCIS (Netherlands)

    van Rooij, F.; Maaskant, A.; Weijers, I.; Weijers, D.; Hermanns, J.

    2015-01-01

    This study examined the role of placement and child characteristics in the unplanned termination of foster placements. Data were used from 169 foster children aged 0 to 20. Results showed that 35% of all foster placement terminations were unplanned. Outcomes of logistic regression analyses

  4. The effect of poling conditions on the performance of piezoelectric energy harvesters fabricated by wet chemistry

    KAUST Repository

    Fuentes-Fernandez, Erika Maria-Anai

    2015-03-25

    The effect of poling conditions on the power output of piezoelectric energy harvesters using sol-gel based Pb(Zr0.53,Ti0.47)O3-Pb(Zn1/3,Nb2/3)O3 piezoelectric thin-films has been investigated. A strong correlation was established between the poling efficiency and harvester output. A method based on simple capacitance-voltage measurements is shown to be an effective approach to estimate the power output of harvesters poled under different conditions. The poling process was found to be thermally activated with an activation energy of 0.12 eV, and the optimum poling conditions were identified (200 kV cm-1, 250 °C for 50 min). The voltage output and power density obtained under optimum poling conditions were measured to be 558 V cm-2 and 325 μW cm-2, respectively. © The Royal Society of Chemistry.2015.

  5. Field analysis and enhancement of multi-pole magnetic components fabricated on printed circuit board

    International Nuclear Information System (INIS)

    Chiu, K.-C.; Chen, C.-S.

    2007-01-01

    A multi-pole magnetic component magnetized with a fine magnetic pole pitch of less than 1 mm is very difficult to achieve by using traditional methods. Moreover, it requires a precise mechanical process and a complicated magnetization system. Different fine magnetic pole pitches of 300, 350 and 400 μm have been accomplished on 9-pole magnetic components through the printed circuit board (PCB) manufacturing technology. Additionally, another fine magnetic pole pitch of 500 μm was also fabricated on a dual-layered (DL) wire circuit structure to investigate the field enhancement. After measurements, a gain factor of 1.37 was obtained in the field strength. The field variations among different magnetic pole pitches were analyzed in this paper

  6. Relative logic cell placement for mitigation of charge sharing-induced transients

    Science.gov (United States)

    Kiddie, Bradley T.; Robinson, William H.

    2016-10-01

    Design of modern integrated circuits increasingly requires consideration of radiation effects, especially in space and other high-risk environments. With fabrication technologies scaling down both feature sizes and critical charge, a radiation strike in sub-100 nm technologies may affect multiple, physically adjacent nodes. With increasing clock speeds, transient errors in the processing datapath also increase in risk. Modeling single-event multiple-transients (SEMT) for pre-fabrication reliability characterization has become a more common design step, and this work adds to the state-of-the-art by providing a fast and physically-informed characterization flow that captures the effects of single-event multiple-node charge collection through experimentally observed transport mechanisms. Beyond characterization, the study of SEMT vulnerabilities reveals the electronic design automation (EDA) step of standard logic cell placement as a design space for hardening against SEMT-induced errors. This work: (1) analyzes the vulnerability of benchmark circuits against SEMT errors, (2) evaluates the impact of logic on transient propagation, (3) explores EDA placement techniques, and (4) builds an automated design flow for relative placement of cells to mask transient errors, while maintaining compatibility with other radiation hardening techniques. Zero cost to area and marginal impact on timing enable this new cell placement algorithm that masks 30% of SEMT-induced errors.

  7. Ultrasonography for confirmation of gastric tube placement.

    Science.gov (United States)

    Tsujimoto, Hiraku; Tsujimoto, Yasushi; Nakata, Yukihiko; Akazawa, Mai; Kataoka, Yuki

    2017-04-17

    Gastric tubes are commonly used for the administration of drugs and tube feeding for people who are unable to swallow. Feeding via a tube misplaced in the trachea can result in severe pneumonia. Therefore, the confirmation of tube placement in the stomach after tube insertion is important. Recent studies have reported that ultrasonography provides good diagnostic accuracy estimates in the confirmation of appropriate tube placement. Hence, ultrasound could provide a promising alternative to X-rays in the confirmation of tube placement, especially in settings where X-ray facilities are unavailable or difficult to access. To assess the diagnostic accuracy of ultrasound for gastric tube placement confirmation. We searched the Cochrane Library (2016, Issue 3), MEDLINE (to March 2016), Embase (to March 2016), National Institute for Health Research (NIHR) PROSPERO Register (to May 2016), Aggressive Research Intelligence Facility Databases (to May 2016), ClinicalTrials.gov (to May 2016), ISRCTN registry (May 2016), World Health Organization International Clinical Trials Registry Platform (to May 2016) and reference lists of articles, and contacted study authors. We included studies that evaluated the diagnostic accuracy of naso- and orogastric tube placement confirmed by ultrasound visualization using X-ray visualization as the reference standard. We included cross-sectional studies, and case-control studies. We excluded case series or case reports. Studies were excluded if X-ray visualization was not the reference standard or if the tube being placed was a gastrostomy or enteric tube. Two review authors independently assessed the risk of bias and extracted data from each of the included studies. We contacted authors of the included studies to obtain missing data. We identified 10 studies (545 participants and 560 tube insertions) which met our inclusion criteria.No study was assigned low risk of bias or low concern in every QUADAS-2 domain. We judged only three (30

  8. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  9. Lower Pole Calyceal Stone and Lithotripsy are Issues with Clearance Fact or Reality?

    Directory of Open Access Journals (Sweden)

    M. Hammad Ather

    2013-12-01

    Full Text Available The lower pole calyceal (LPC stone continues to be an enigma. The complex anatomy of the lower pole collecting system, along with other factors like acute pelvi calyceal angle and narrow and long infundibulum, are some of the complicating factors affecting stone clearance. There have been many studies assessing the impact of collecting system anatomy and most conclude that the complex anatomy of the lower pole collecting system does impact the overall stone-free rate.

  10. The Dimensions and Pole of Asteroid (21) Lutetia from Adaptive Optics Images

    Science.gov (United States)

    Drummond, Jack D.; Conrad, A.; Merline, W.; Carry, B.

    2009-09-01

    In a campaign to study the Rosetta mission target, asteroid (21) Lutetia, we obtained 81 images on December 2, 2008, at 2.12 microns with adaptive optics (AO) on the Keck-II 10 m telescope. From these nearly consecutive images obtained over a quarter of rotation, we have determined the asteroid's triaxial ellipsoid diameters to be 132x101x76 km, with formal uncertainties of 1 km for the equatorial dimensions, and 31 km for the shortest axis. This latter uncertainty occurs because the observations were made at the relatively high sub-Earth latitude of -69 degrees. From these observations we determine that Lutetia's pole lies at 2000.0 coordinates of RA=48, Dec=+9, or Ecliptic coordinates of [49;-8], with a formal uncertainty radius of 3 deg. (The other possible pole is eliminated by considering its lightcurve history.) The rotational pole derived for the lightcurve inversion model (available at http://astro.troja.mff.cuni.cz/ projects/asteroids3D/web.php), is only 5 deg from ours, but comparing our images to the lightcurve inversion model we find that Lutetia is more pointed than the model. Our technique of deriving the dimensions of asteroids from AO images has been calibrated against Pluto and 4 satellites of Saturn with precise diameters, and we find that any systematic errors can be no more than 1-3%. We acknowledge the assistance of other team members Christophe Dumas (ESO), Peter Tamblyn (SwRI), and Clark Chapman (SwRI). We also thank Hal Weaver (JHU/APL) as the lead for our collaboration with the Rosetta mission. We are grateful for telescope time made available to us by S. Kulkarni and M. Busch (Cal Tech) for a portion of our overall Lutetia effort. We also thank our collaborators on Team Keck, the Keck science staff, for making possible some of the Lutetia observations and for their participation. Additional Lutetia observations were acquired at Gemini North under NOAO time allocation.

  11. Placement Strategies of World's Top Business Schools

    OpenAIRE

    Varun Shenoy; Aithal P. S .

    2017-01-01

    Institutional Ranking in higher education space has become a very important practice and management institutions across the world are greatly profited by the published global rankings based on various criterions. The ranking is usually publicized depending upon Institutional infrastructure, their employment &placements, teaching pedagogy, research output, faculty-student ratio, international linkage, application of technology in teaching –learning process etc. In this study, we have chosen to...

  12. A Placement Model for Flight Simulators.

    Science.gov (United States)

    1982-09-01

    simulator basing strategies. Captains David R. VanDenburg and Jon D. Veith developed a mathematical model to assist in the placement analysis of A-7...Institute for Defense Analysis, Arlington VA, August 1977. AD A049979. 23. Sugarman , Robert C., Steven L. Johnson, and William F. H. Ring. "B-I Systems...USAF Cost and Plan- nin& Factors. AFR 173-13. Washington: Govern- ment Printing Office, I February 1982. * 30. Van Denburg, Captain David R., USAF

  13. FPGA Congestion-Driven Placement Refinement

    Energy Technology Data Exchange (ETDEWEB)

    Vicente de, J.

    2005-07-01

    The routing congestion usually limits the complete proficiency of the FPGA logic resources. A key question can be formulated regarding the benefits of estimating the congestion at placement stage. In the last years, it is gaining acceptance the idea of a detailed placement taking into account congestion. In this paper, we resort to the Thermodynamic Simulated Annealing (TSA) algorithm to perform a congestion-driven placement refinement on the top of the common Bounding-Box pre optimized solution. The adaptive properties of TSA allow the search to preserve the solution quality of the pre optimized solution while improving other fine-grain objectives. Regarding the cost function two approaches have been considered. In the first one Expected Occupation (EO), a detailed probabilistic model to account for channel congestion is evaluated. We show that in spite of the minute detail of EO, the inherent uncertainty of this probabilistic model impedes to relieve congestion beyond the sole application of the Bounding-Box cost function. In the second approach we resort to the fast Rectilinear Steiner Regions algorithm to perform not an estimation but a measurement of the global routing congestion. This second strategy allows us to successfully reduce the requested channel width for a set of benchmark circuits with respect to the widespread Versatile Place and Route (VPR) tool. (Author) 31 refs.

  14. Experiences of Supervision at Practice Placement Sites

    Directory of Open Access Journals (Sweden)

    Lesley Diack

    2014-01-01

    Full Text Available Background. Whilst placement supervision and clinical education programmes are of significant value in shaping the behaviours of undergraduate healthcare students, appropriate provisions which are efficacious to the learner are somewhat lacking, particularly for students studying on UK MPharm programmes. Objectives. To explore and explain the value of placement supervision to the personal development and employability of undergraduate pharmacy students. Methods. Students participated in a week long community pharmacy pilot programme, a result of a collaborative effort between the School of Pharmacy and Life Sciences and a small consortium of community pharmacies. Students and stakeholders were asked to evaluate their experiences via separate questionnaires which had been developed to elicit views and attitudes. Key Findings. Feedback from students and stakeholders towards the experience was overwhelmingly positive with multiple benefits being reported. Of particular prominence was the emphasis in student feedback on the value of placement supervision to their professional and personal development. Findings were indicative of a development in clinical practice proficiencies, core skills, and improvement in decision-making practice. Conclusions. The benefits of clinical supervision to the professional and personal development of MPharm students are well documented, although attracting professional pharmacy supervisors is proving a problematic task for educational providers in the UK.

  15. Can donated media placements reach intended audiences?

    Science.gov (United States)

    Cooper, Crystale Purvis; Gelb, Cynthia A; Chu, Jennifer; Polonec, Lindsey

    2013-09-01

    Donated media placements for public service announcements (PSAs) can be difficult to secure, and may not always reach intended audiences. Strategies used by the Centers for Disease Control and Prevention's (CDC) Screen for Life: National Colorectal Cancer Action Campaign (SFL) to obtain donated media placements include producing a diverse mix of high-quality PSAs, co-branding with state and tribal health agencies, securing celebrity involvement, monitoring media trends to identify new distribution opportunities, and strategically timing the release of PSAs. To investigate open-ended recall of PSAs promoting colorectal cancer screening, CDC conducted 12 focus groups in three U.S. cities with men and women either nearing age 50 years, when screening is recommended to begin, or aged 50-75 years who were not in compliance with screening guidelines. In most focus groups, multiple participants recalled exposure to PSAs promoting colorectal cancer screening, and most of these individuals reported having seen SFL PSAs on television, in transit stations, or on the sides of public buses. Some participants reported exposure to SFL PSAs without prompting from the moderator, as they explained how they learned about the disease. Several participants reported learning key campaign messages from PSAs, including that colorectal cancer screening should begin at age 50 years and screening can find polyps so they can be removed before becoming cancerous. Donated media placements can reach and educate mass audiences, including millions of U.S. adults who have not been screened appropriately for colorectal cancer.

  16. Shadow poles in coupled-channel problems calculated with the Berggren basis

    Science.gov (United States)

    Id Betan, R. M.; Kruppa, A. T.; Vertse, T.

    2018-02-01

    Background: In coupled-channels models the poles of the scattering S matrix are located on different Riemann sheets. Physical observables are affected mainly by poles closest to the physical region but sometimes shadow poles have considerable effect too. Purpose: The purpose of this paper is to show that in coupled-channels problems all poles of the S matrix can be located by an expansion in terms of a properly constructed complex-energy basis. Method: The Berggren basis is used for expanding the coupled-channels solutions. Results: The locations of the poles of the S matrix for the Cox potential, constructed for coupled-channels problems, were numerically calculated and compared with the exact ones. In a nuclear physics application the Jπ=3 /2+ resonant poles of 5He were calculated in a phenomenological two-channel model. The properties of both the normal and shadow resonances agree with previous findings. Conclusions: We have shown that, with an appropriately chosen Berggren basis, all poles of the S matrix including the shadow poles can be determined. We have found that the shadow pole of 5He migrates between Riemann sheets if the coupling strength is varied.

  17. Time domain oscillating poles: Stability redefined in Memristor based Wien-oscillators

    KAUST Repository

    Talukdar, Abdul Hafiz Ibne

    2012-07-28

    Traditionally, the necessary and sufficient condition for any system to be oscillating is that its poles are located on the imaginary (jω) axis. In this paper, for the first time, we have shown that systems can oscillate with time-domain oscillating poles. The idea is verified using a Memristor based Wien oscillator. Sustained oscillations are observed without having the poles of the system fixed on the imaginary axis and the oscillating behavior of the system poles is reported. The oscillating resistance and triangular shape of FFT are also demonstrated with mathematical reasoning and simulation results to support the unusual and surprising characteristics. © 2009 IEEE.

  18. Paving the Way for Implant Placement for an Auricular Prosthesis

    Directory of Open Access Journals (Sweden)

    Dipti S Shah

    2013-01-01

    Full Text Available Background: Ideal placement of bone integrated implants to retain a prosthesis is critical for a successful final prosthetic restoration. Several sources have described the importance and use of surgical templates for the optimal placement of extraoral implants. The literature is replete with information explaining the use of surgic al templates for intraoral implant placement. Indeed, correct placement of implants facilitates creating a prosthesis that functions well and looks natural. To ensure proper implant placement, considerable effort should go into pre-surgical planning. It is clear that extraoral surgical templates aid in proper implant placement, yet the literature describing fabrication is limited. This article describes different methods for fabrication of surgical template for placement of implants for an auricular prosthesis.

  19. Factors affecting the placement or replacement of direct restorations in a dental school

    Directory of Open Access Journals (Sweden)

    Samara Silvani

    2014-01-01

    Full Text Available Context: The knowledge of the reasons for the placement of direct restorations makes possible to trace an epidemiological profile of a specific population and to direct the teaching of dentistry to techniques that are commonly used today and will be continued performed in the future. Purpose: The aim of this study was to verify the reasons for placement and replacement of direct restorations in patients treated in the Dental Clinic of the Uberaba University - Brazil. Materials and Methods: This study evaluated 306 restorative procedures carried out on 60 patients. During the treatment planning, a form that contained information about the patient′s gender, tooth number, the classification of restorations, the reasons for placement and replacement of amalgam and tooth-colored restorations, the material that had to be removed and the new material used to fill the cavities was filled for each patient. Statistical analysis was carried out using Chi-square test (α = 0.05. Results: The data showed that most of the patients were female (66.7%. Of all the restorations placed, 60.45% were 1 st -time placements, while 39.55% were replacements. For 1 st -time restorations, the main reason for placement was primary caries (76.76%, followed by non-carious cervical lesions (15.14%. The amalgam restorations were replaced more frequently (67.77%. The primary reason for replacements was the presence of secondary caries (for both previous amalgam (42.68% and composite (66.67% restorations (P < 0.05. The resin composite was the most indicated material for the new restorations (98.04% (P < 0.05. Conclusions: The main reason for placement of direct restorations was primary caries, while secondary caries was the main reason for replacements. In almost all cases, the material used to fill the cavities was the resin composite.

  20. Relative placement of the mandibular fossa in great apes and humans.

    Science.gov (United States)

    Sherwood, Richard J; Rowley, Rebecca B; Ward, Steven C

    2002-07-01

    Several researchers have investigated, or commented on, the relative placement of the hominin mandibular fossa with regard to brain expansion and masticatory function. Two confounding factors are identified in this previous work. First, a number of different measurement techniques have been applied, confusing comparisons between studies. Second, the effects of squamous thickening due to temporal bone pneumatization are shown to influence measurements based relative to the ectocranial margin of the skull. To investigate the influence of these factors, a sample of adult human (n=12), chimpanzee (n=12), gorilla (n=15), and orang-utan (n=8) skulls from the Cleveland Museum of Natural History, University of Wisconsin Zoology Museum, and University of Wisconsin Anthropology collections, were CT scanned. Coronal scans were horizontally aligned and measured on a personal computer using ImageJ (NIH). To identify fossa placement, fossa breadth was measured as the projected distance in the coronal plane between the tip of the entoglenoid to lateral margin of the articular surface. A second distance, from the tip of the entoglenoid to a sagittal plane, tangent to the lateralmost margin of the endocranial surface was taken to indicate the extent of medial placement of the fossa. By eliminating the influence of pneumatization, these data unambiguously confirmed the medial placement of the human fossa and show all great apes as having a laterally placed fossa. Similar measurements on three fossil hominins, KNM-BC 1 (Homo sp. indet.), OH 5 and KNM-ER 23000 (Paranthropus boisei) demonstrate that, while all specimens demonstrate a broad fossa, only KNM-BC 1 is characterized by a relatively medial placement while the latter two display lateral placement. Copyright 2002 Elsevier Science Ltd. All rights reserved.

  1. Pipe type poles in transmission power lines; Postes tipo tubo en lineas de transmision

    Energy Technology Data Exchange (ETDEWEB)

    Cervantes E, Mario; Becerril A, Armando [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    The first supports for transmission power lines were relatively small structures, of simple configuration, to save reduced clearances to resist load in accordance with its need; with the technical development, gradually appeared higher and higher electric tensions and greater obstacles to overcome, consequently the design of the supports had to be adapted to the new conditions. This gave rise to the development of a specific technique that would adequate and incorporate the continuous engineering advances. In this document the initial considerations on the design poles pipe type are examined; within these considerations mention is made of: the design, the manufacture, the prototype tests, installation, quality control and foundations. The type tube pole is portrayed, as well as the steel reinforcement, finally the types of precast foundations are shown [Espanol] Los primeros soportes para lineas de transmision fueron estructuras relativamente pequenas, de configuracion simple, para salvar claros reducidos y resistir cargas proporcionales a sus necesidades, con el desarrollo de la tecnica, fueron apareciendo tensiones electricas cada vez mas elevadas y obstaculos mayores que vencer, por lo que el diseno de los soportes tuvo que adaptarse a las nuevas condiciones. Esto dio origen al desenvolvimiento de una tecnica especifica que fuese adecuando e incorporando los continuos avances de la ingenieria. En este documento se tratan las consideraciones iniciales del diseno de los postes tipo tubo; dentro de estas consideraciones se citan: el diseno, la fabricacion, las pruebas de prototipo, montajes, control de calidad y cimentaciones. Se ilustra el poste tipo tubo, al igual que el armado del poste, por ultimo se muestra los tipos de cimentaciones precoladas

  2. Dental cone beam computed tomography analyses of postoperative labial bone thickness in maxillary anterior implants: comparing immediate and delayed implant placement.

    Science.gov (United States)

    Miyamoto, Yasukazu; Obama, Tadakazu

    2011-06-01

    This study aimed to evaluate the influence of labial alveolar bone thickness and the corresponding vertical bone loss on postoperative gingival recessions around anterior maxillary dental implants. Using cone beam computed tomography (CBCT) scanning, the temporal changes of three-dimensional images of alveolar bone were monitored to determine hard and soft tissue outcomes of two different implant placement techniques: delayed two-stage and immediate placement. Furthermore, for the delayed two-stage placement, guided bone regeneration was applied using either nonresorbable or resorbable membranes combined with anorganic bovine bone matrix. The comparative results suggested that gingival recessions were significantly lower in delayed two-stage placement, especially when using a nonresorbable membrane, compared to immediate placement, and labial bone thickness, measured by CBCT, offered an effectual indicator to assess gingival recession in the anterior region.

  3. Modern recording techniques

    CERN Document Server

    Huber, David Miles

    2013-01-01

    As the most popular and authoritative guide to recording Modern Recording Techniques provides everything you need to master the tools and day to day practice of music recording and production. From room acoustics and running a session to mic placement and designing a studio Modern Recording Techniques will give you a really good grounding in the theory and industry practice. Expanded to include the latest digital audio technology the 7th edition now includes sections on podcasting, new surround sound formats and HD and audio.If you are just starting out or looking for a step up

  4. Roadside tree/pole crash barrier field test

    Science.gov (United States)

    Wilson, A. H.

    1979-01-01

    A series of tests was carried out to evaluate the performance of a crash barrier designed to protect the occupants of an automobile from serious injury. The JPL barrier design is a configuration of empty aluminum beverage cans contained in a tear-resistant bag which, in turn, is encased in a collapsible container made of plywood and steel. Tests were conducted with a driven vehicle impacting the barrier. The basic requirements of NCHRP Report 153 were followed except that speeds of 30 mph rather than 60 mph were used. Accelerometer readings on the driver's helmet showed that the driver was never subjected to dangerous decelerations, and never experienced more than temporary discomfort. Also, all of the requirements of the cited report were met. An extrapolation of data indicated that the JPL barrier installed in front of a tree or telephone pole along a roadside would also have met the requirements at a speed of 40 mph.

  5. Lunar South Pole space water extraction and trucking system

    International Nuclear Information System (INIS)

    Zuppero, A.; Zupp, G.; Schnitzler, B.; Larson, T.K.; Rice, J.W.

    1998-03-01

    This concept proposes to use thermal processes alone to extract water from the lunar South Pole and launch payloads to low lunar orbit. Thermal steam rockets would use water propellant for space transportation. The estimated mass of a space water tanker powered by a nuclear heated steam rocket suggests it can be designed for launch in the Space Shuttle bay. The performance depends on the feasibility of a nuclear reactor rocket engine producing steam at 1,100 degrees Kelvin, with a power density of 150 Megawatts per ton of rocket, and operating for thousands of 20 minute cycles. An example uses reject heat from a small nuclear electric power supply to melt 17,800 tons per year of lunar ice. A nuclear heated steam rocket would use the propellant water to launch and deliver 3,800 tons of water per year to a 100 km low lunar orbit

  6. Bacterial diversity in snow on North Pole ice floes

    DEFF Research Database (Denmark)

    Hauptmann, Aviaja Zenia Edna Lyberth; Stibal, Marek; Bælum, Jacob

    2014-01-01

    sites clustered together when compared to the underlying environments of sea ice and ocean water. The Shannon indices ranged from 2.226 to 3.758, and the Chao1 indices showed species richness between 293 and 353 for the three samples. The relatively low abundances and diversity found in the samples......The microbial abundance and diversity in snow on ice floes at three sites near the North Pole was assessed using quantitative PCR and 454 pyrosequencing. Abundance of 16S rRNA genes in the samples ranged between 43 and 248 gene copies per millilitre of melted snow. A total of 291,331 sequences were...... indicate a lower rate of microbial input to this snow habitat compared to snow in the proximity of terrestrial and anthropogenic sources of microorganisms. The differences in species composition and diversity between the sites show that apparently similar snow habitats contain a large variation...

  7. Ruthenium therapy of choroidal melanomas of the posterior pole

    International Nuclear Information System (INIS)

    Langmann, G.; Faschinger, C.; Langmann, A.; Poier, E.

    1992-01-01

    The indications for conservative treatment of intraocular melanomas of the posterior pole with radioactive plaques are controversial. Melanomas located at the macula or adjacent to the fovea are regarded as relative contraindications for conservative treatment. Three melanomas of the macula have been treated at our department meanwhile. The tumor elevation ranged between 3.5 and 6 mm, the distance to the fovea between 0.5 and 2 dd. An average radiation dosage between 130 and 160 Gy was delivered to the apex of the tumors. The duration of observation was between 12 months to 4 years. The tumor regression was satisfactory in all 3 cases, additional photocoagulation was necessary in one case of incomplete tumor regression. Pretreatment visual acuity ranged between 0.8 and 0.1, posttreatment visual acuity between 0.8 and 0.25. In one case we observed a local radiation vasculopathy. General examination did not reveal any signs of metastases. (authors)

  8. Comparison of three methods for the confirmation of laryngeal mask airway placement in female patients undergoing gynecologic surgery.

    Science.gov (United States)

    Zhou, Zhen-feng; Xia, Chen-zhong; Wu, Meng; Yu, Li-na; Yan, Guo-zhang; Ren, Qiu-sheng; Hu, Ci-xian; Yan, Min

    2015-05-01

    The laryngeal mask airway (LMA) is a supraglottic device that is commonly used to provide lung ventilation during general anesthesia. LMA placement needs to be confirmed to provide adequate lung ventilation. To investigate the feasibility of using ultrasound examination, compared with clinical tests and fiberoptic laryngoscopy, to confirm LMA placement, we performed a clinical study of 64 female patients classified as American Society of Anesthesiologists Physical Status I or II who were scheduled for gynecologic surgery with LMA insertion for airway management. After insertion, placement of the LMA was confirmed by clinical tests, ultrasound examination and fiberoptic laryngoscopy. Of the 64 women, placement was confirmed as acceptable in 89.1% by clinical tests, in 59.4% by fiberoptic laryngoscope assessment and in 67.2% by ultrasound examination. With respect to patients with oropharyngeal leaks classified as high, there were no differences in confirmation of acceptable placement between clinical tests and ultrasound examinations (p = 0.092), but the number of patients determined to have acceptable placement by ultrasound examination was greater than that determined by fiberoptic laryngoscopy (p = 0.034). Thus, ultrasound examination is a superior technique for confirming the seal on the LMA. Copyright © 2015. Published by Elsevier Inc.

  9. [Acoustic emission diagnostic techniques for high-field high current-density super inducting poles

    International Nuclear Information System (INIS)

    1990-01-01

    Acoustic emission technology was introduced in the late 1970's to monitor superconducting magnets. It has now been firmly established that acoustic signals in superconducting magnets are emitted principally by mechanical events such as conductor strain, conductor motion, frictional motion, and epoxy cracking. Despite earlier suggestions, flux motion, except during flux jumping, does not appear to be an important source of AE signals in superconducting magnets. Of these several potential sources of AE signals in superconducting magnets, mechanical disturbances have been identified to be most important in high-performance, ''adiabatic'' magnets such as the dipoles used in accelerators. These mechanical disturbances are transitory, each generating a packet of AE signals that can be located with sensors. Source identification and location has been achieved with a number of superconducting magnets. In this section, the basic principle for the operation of adiabatic magnets is discussed, followed by presentation of some of the important experimental results relevant to the question of premature quench obtained at MIT

  10. Analysis of magnetic abrasive finishing with slotted magnetic pole

    Science.gov (United States)

    Jayswal, S. C.; Jain, V. K.; Dixit, P. M.

    2004-06-01

    Magnetic Abrasive Finishing (MAF) is relatively a new finishing process among the advanced finishing processes in which the workpiece is kept in the magnetic field created by two poles of an electromagnet. The working gap between the workpiece and the magnet is filled with magnetic abrasive particles. A flexible magnetic abrasive brush is formed, acting as a multipoint cutting tool, due to the effect of magnetic field in the working gap. This process is capable of producing the surface finish of nanometer range. Most of the researchers have been using the electromagnet having a slot in it to improve the performance of the process but hardly any information is available about its effect on the process performance. This paper deals with the effect of a slot made in the electromagnet on the forces and surface quality during MAF. An experimental set-up is designed and fabricated for the measurement of the magnetic field distribution in the working gap. The magnetic field is simulated using a finite element model of the process. The magnetic field is also measured experimentally to validate the theoretical results. It indicates a good agreement between the experimental results and simulated values. The finite element method is further used for the evaluation of the magnetic force and surface quality during MAF. To our surprise it is found that the force under the slot is negative, even then process performance is improved. MAF process removes a very small amount of material by indentation and rotation of the magnetic abrasive particles in the circular tracks. Due to rotation of the magnetic abrasive flexible brush, grooves are formed on the workpiece surface which decides the surface profile after MAF. Surface quality is determined on the basis of the surface profile achieved by equating the volume of groove produced. These results show an improvement in finishing rate while using a slotted pole surface.

  11. Determination of regional Euler pole parameters for Eastern Austria

    Science.gov (United States)

    Umnig, Elke; Weber, Robert; Schartner, Matthias; Brueckl, Ewald

    2017-04-01

    The horizontal motion of lithospheric plates can be described as rotations around a rotation axes through the Earth's center. The two possible points where this axes intersects the surface of the Earth are called Euler poles. The rotation is expressed by the Euler parameters in terms of angular velocities together with the latitude and longitude of the Euler pole. Euler parameters were calculated from GPS data for a study area in Eastern Austria. The observation network is located along the Mur-Mürz Valley and the Vienna Basin. This zone is part of the Vienna Transfer Fault, which is the major fault system between the Eastern Alps and the Carpathians. The project ALPAACT (seismological and geodetic monitoring of ALpine-PAnnonian ACtive Tectonics) investigated intra plate tectonic movements within the Austrian part in order to estimate the seismic hazard. Precise site coordinate time series established from processing 5 years of GPS observations are available for the regional network spanning the years from 2010.0 to 2015.0. Station velocities with respect to the global reference frame ITRF2008 have been computed for 23 sites. The common Euler vector was estimated on base of a subset of reliable site velocities, for stations directly located within the area of interest. In a further step a geokinematic interpretation shall be carried out. Therefore site motions with respect to the Eurasian Plate are requested. To obtain this motion field different variants are conceivable. In a simple approach the mean ITRF2008 velocity of IGS site GRAZ can be adopted as Eurasian rotational velocity. An improved alternative is to calculate site-specific velocity differences between the Euler rotation and the individual site velocities. In this poster presentation the Euler parameters, the residual motion field as well as first geokinematic interpretation results are presented.

  12. FROM BRAND PLACEMENT TO TOURISM PRODUCT PLACEMENT. FICTION SERIES AS PROMOTIONAL SUPPORT OF SPANISH TOURISM DESTINATIONS

    Directory of Open Access Journals (Sweden)

    Noelia Araújo-Vila

    2011-12-01

    Full Text Available Every day more consumers spend much of their free time to the consumption of audiovisual series, which is reflected in the notable increase in downloads and audiences. Therefore, many sectors have decided to use audiovisual series as advertising (brand placement, being one of them the tourism sector (tourism product placement. There are many worldwide destinations that have decided to set in a fiction series, thus being viewed by thousands of spectators, which has resulted in increases in visitors. In the Spanish case is not so clear the use of this strategy, as it is analysed in this article.

  13. Stressed out or subjective acquisition of competence – how do veterinary students see their curative work placement?

    Science.gov (United States)

    Dilly, Marc; Tipold, Andrea; Geuenich, Katja

    2016-01-01

    Veterinary studies in Germany are regulated by the Veterinary Certification Act (TAppV). The practical part of the education consists of 1,170 hours, whereby up to 850 hours can be spent on the curative work placement. A curative work placement can result in physical and psychological stress in the sense of a professional overload. It is the aim of this study to find out in what areas and to what extent competence is acquired and psychological stress exists in students during their work placement. Veterinary students (n=142) from all German education institutes participated in a voluntary online-study based on Burnout Screening Scales (BOSS) as well as a questionnaire regarding the acquisition of competence and excessive stress during the work placement (FKÜP). The distribution of values for work placement related stress show that such work placement related stress is generally slightly increased (T=60) and lies above that of occupational stresses within the normal population. Work placement related physical complaints also show a significant slight increase (T=61). A value (T=42) within the normal range was determined for the resource values. Few of the students questioned considered themselves to be excessively stressed in favour of a high subjective acquisition of competences. The largest increase regarding the acquisition of competence was noted for the areas of animal handling/restraint and application and injection techniques. In the sense of a perceived excessive demand regarding practical capabilities the areas of emergency management, surgery and medication dispensation were mentioned. With regard to the load structure and the acquisition of competence by veterinary students during their work placement, more support of the individual and a balancing of teaching/learning goals would be desirable and represents a promising approach. PMID:26958657

  14. Stressed out or subjective acquisition of competence – how do veterinary students see their curative work placement?

    Directory of Open Access Journals (Sweden)

    Dilly, Marc

    2016-02-01

    Full Text Available Veterinary studies in Germany are regulated by the Veterinary Certification Act (TAppV. The practical part of the education consists of 1,170 hours, whereby up to 850 hours can be spent on the curative work placement. A curative work placement can result in physical and psychological stress in the sense of a professional overload. It is the aim of this study to find out in what areas and to what extent competence is acquired and psychological stress exists in students during their work placement. Veterinary students (n=142 from all German education institutes participated in a voluntary online-study based on Burnout Screening Scales (BOSS as well as a questionnaire regarding the acquisition of competence and excessive stress during the work placement (FKÜP. The distribution of values for work placement related stress show that such work placement related stress is generally slightly increased (T=60 and lies above that of occupational stresses within the normal population. Work placement related physical complaints also show a significant slight increase (T=61. A value (T=42 within the normal range was determined for the resource values. Few of the students questioned considered themselves to be excessively stressed in favour of a high subjective acquisition of competences. The largest increase regarding the acquisition of competence was noted for the areas of animal handling/restraint and application and injection techniques. In the sense of a perceived excessive demand regarding practical capabilities the areas of emergency management, surgery and medication dispensation were mentioned. With regard to the load structure and the acquisition of competence by veterinary students during their work placement, more support of the individual and a balancing of teaching/learning goals would be desirable and represents a promising approach.

  15. Stressed out or subjective acquisition of competence--how do veterinary students see their curative work placement?

    Science.gov (United States)

    Dilly, Marc; Tipold, Andrea; Geuenich, Katja

    2016-01-01

    Veterinary studies in Germany are regulated by the Veterinary Certification Act (TAppV). The practical part of the education consists of 1,170 hours, whereby up to 850 hours can be spent on the curative work placement. A curative work placement can result in physical and psychological stress in the sense of a professional overload. It is the aim of this study to find out in what areas and to what extent competence is acquired and psychological stress exists in students during their work placement. Veterinary students (n=142) from all German education institutes participated in a voluntary online-study based on Burnout Screening Scales (BOSS) as well as a questionnaire regarding the acquisition of competence and excessive stress during the work placement (FKÜP). The distribution of values for work placement related stress show that such work placement related stress is generally slightly increased (T=60) and lies above that of occupational stresses within the normal population. Work placement related physical complaints also show a significant slight increase (T=61). A value (T=42) within the normal range was determined for the resource values. Few of the students questioned considered themselves to be excessively stressed in favour of a high subjective acquisition of competences. The largest increase regarding the acquisition of competence was noted for the areas of animal handling/restraint and application and injection techniques. In the sense of a perceived excessive demand regarding practical capabilities the areas of emergency management, surgery and medication dispensation were mentioned. With regard to the load structure and the acquisition of competence by veterinary students during their work placement, more support of the individual and a balancing of teaching/learning goals would be desirable and represents a promising approach.

  16. Easy Suprapubic Tube Placement Using a Van Buren Sound.

    Science.gov (United States)

    Wyner, Lawrence M

    2018-01-17

    To place a suprapubic tube without using specialized instruments. Suprapubic cystostomy is a straightforward urological procedure, which nevertheless may become complicated if the equipment needed to perform the operation is unavailable. Nowadays, in most operating rooms, control of urological instruments has been taken away from a small cadre of dedicated urology nurses, and instead is delegated to a central sterilization department or is even outsourced, leading to an increased rate of instrument misplacement or breakage. Disposable kits are useful, but may not be stocked at all facilities. Hence, the tools needed by the urologist to perform suprapubic cystostomy may not be readily available when they are needed. This reality was the impetus for the development of the following technique for suprapubic tube placement, which relies only upon ordinary instruments. A simple method is described for placing a suprapubic catheter using a curved Van Buren sound, a cystoscope, and a minor surgical set. Not only is the operation is easy to do, but is also advantageous in that the catheter may be exchanged over a wire, if necessary, before the establishment of a suprapubic tract. The technique depends on the presence of an intact urethra; therefore, it is contraindicated in the setting of pelvic trauma. This suprapubic cystostomy method may be used either as a primary technique or as a back-up procedure if the urologist's preferred instrumentation is not available. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Development of a field pole of 1 MW-class HTS motor

    International Nuclear Information System (INIS)

    Yuan, S; Kimura, Y; Miki, M; Felder, B; Tsuzuki, K; Izumi, M; Ida, T; Umemoto, K; Aizawa, K; Yokoyama, M

    2010-01-01

    We report a field-pole high-temperature superconductor (HTS) magnet designed for 1 MW-class motor for propulsion. The field pole is assembled to the rotor of the radial-type motor. Each field pole is composed of HTS-Bi2223 tape wound into coils which have been piled up as a double pancake coils. In the design concept of the motor, we employ field poles without iron core. We prepared the test field-pole coil, whose dimension is smaller than the designed one for 1 MW, and tested its performances after cooling under self-field and external magnetic field. We verified the operation with the minimum bend radius of the coils required in the motor design, while keeping an optimal current which is lower than the critical current of the field-pole coil. The test HTS field poles were successfully cooled down and operated under a magnetic field ranging up to 5 T. We report the results of the test field-pole coil and the manufacture of a practical racetrack coil with Bi2223 and discuss the adaptability to 1 MW-class motors.

  18. Experience on impregnation of wood.en poles with water borne salts

    African Journals Online (AJOL)

    part of pole treated. To ensure this diffusion of the preservative all around, the pole is pricked every. 8 - 10 cm. vertically and 4 - 5 cm peripherally. The treatment with COBRA was discontinued soon after for the following reasons:- I. Leechability. Since the process depends on osmosis, the preservative must be highly soluble ...

  19. The practice of pole dance as a leisure activity in Denmark

    DEFF Research Database (Denmark)

    Jensen, Andorra Lynn

    2015-01-01

    The aim of this study is to explore the how pole dance is practiced as a form of leisure activity in Denmark. The methodical approach is qualitative and inspired by ethnography. I have conducted a field study where I have observed and participated in the pole dance culture in Copenhagen from May...

  20. Converting point-wise nuclear cross sections to pole representation using regularized vector fitting

    Science.gov (United States)

    Peng, Xingjie; Ducru, Pablo; Liu, Shichang; Forget, Benoit; Liang, Jingang; Smith, Kord

    2018-03-01

    Direct Doppler broadening of nuclear cross sections in Monte Carlo codes has been widely sought for coupled reactor simulations. One recent approach proposed analytical broadening using a pole representation of the commonly used resonance models and the introduction of a local windowing scheme to improve performance (Hwang, 1987; Forget et al., 2014; Josey et al., 2015, 2016). This pole representation has been achieved in the past by converting resonance parameters in the evaluation nuclear data library into poles and residues. However, cross sections of some isotopes are only provided as point-wise data in ENDF/B-VII.1 library. To convert these isotopes to pole representation, a recent approach has been proposed using the relaxed vector fitting (RVF) algorithm (Gustavsen and Semlyen, 1999; Gustavsen, 2006; Liu et al., 2018). This approach however needs to specify ahead of time the number of poles. This article addresses this issue by adding a poles and residues filtering step to the RVF procedure. This regularized VF (ReV-Fit) algorithm is shown to efficiently converge the poles close to the physical ones, eliminating most of the superfluous poles, and thus enabling the conversion of point-wise nuclear cross sections.