WorldWideScience

Sample records for pole placement technique

  1. Current control design for three-phase grid-connected inverters using a pole placement technique based on numerical models

    OpenAIRE

    Citro, Costantino; Gavriluta, Catalin; Nizak Md, H. K.; Beltran, H.

    2012-01-01

    This paper presents a design procedure for linear current controllers of three-phase grid-connected inverters. The proposed method consists in deriving a numerical model of the converter by using software simulations and applying the pole placement technique to design the controller with the desired performances. A clear example on how to apply the technique is provided. The effectiveness of the proposed design procedure has been verified through the experimental results obtained with ...

  2. State-PID Feedback for Pole Placement of LTI Systems

    Directory of Open Access Journals (Sweden)

    Sarawut Sujitjorn

    2011-01-01

    Full Text Available Pole placement problems are especially important for disturbance rejection and stabilization of dynamical systems and regarded as algebraic inverse eigenvalue problems. In this paper, we propose gain formulae of state feedback through PID-elements to achieve desired pole placement for a delay-free LTI system with single input. Real and complex stable poles can be assigned with the proposed compact gain formulae. Numerical examples show that our proposed gain formulae can be used effectively resulting in very satisfactory responses.

  3. H{sub 2}/H{infinity} control of flexible structures through linear matrix inequalities with pole placement

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Jean C. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The objective of this work is to apply the H2/H{infinity} control technique using linear matrix inequalities and pole placement constraints to the flexible structures control problem. The H2/H{infinity}control is a technique to design a controller with mixed features of the H2 and H{infinity} control formulations, such as, optimal dynamical performance and robust performance. The Linear Matrix Inequalities allow formulating the problem as a convex optimization problem, and additional constraints can be included such as the pole placement. The pole placement requirement comes from the necessity of adjusting the transient response of the plant and ensuring a specific behavior in terms of speed and damping responses. The mathematical model used for this study is related to a flexible beam, with an applied disturbance and an actuator in different positions. The state-space matrices of the structure were obtained using the finite element method with the Euler-Bernoulli formulation of beams. The results showed that the pole placement constraints can improve the performance of the controller H2/H{infinity}. The Matlab was used for the computational implementation. (author)

  4. Stabilization, pole placement, and regular implementability

    NARCIS (Netherlands)

    Belur, MN; Trentelman, HL

    In this paper, we study control by interconnection of linear differential systems. We give necessary and sufficient conditions for regular implementability of a-given linear, differential system. We formulate the problems of stabilization and pole placement as problems of finding a suitable,

  5. A Direct Algorithm for Pole Placement by State-derivative Feedback for Single-input Linear Systems

    Directory of Open Access Journals (Sweden)

    Taha H. S. Abdelaziz

    2003-01-01

    Full Text Available This paper deals with the direct solution of the pole placement problem for single-input linear systems using state-derivative feedback. This pole placement problem is always solvable for any controllable systems if all eigenvalues of the original system are nonzero. Then any arbitrary closed-loop poles can be placed in order to achieve the desired system performance. The solving procedure results in a formula similar to the Ackermann formula. Its derivation is based on the transformation of a linear single-input system into Frobenius canonical form by a special coordinate transformation, then solving the pole placement problem by state derivative feedback. Finally the solution is extended also for single-input time-varying control systems. The simulation results are included to show the effectiveness of the proposed approach.

  6. From Beale Number to Pole Placement Design of a Free Piston Stirling Engine

    Directory of Open Access Journals (Sweden)

    Zare Shahryar

    2017-12-01

    Full Text Available In this paper, pole placement-based design and analysis of a free piston Stirling engine (FPSE is presented and compared to the well-defined Beale number design technique. First, dynamic and thermodynamic equations governing the engine system are extracted. Then, linear dynamics of the free piston Stirling engine are studied using dynamic systems theory tools such as root locus. Accordingly, the effects of variations of design parameters such as mass of pistons, stiffness of springs, and frictional damping on the locations of dominant closed-loop poles are investigated. The design procedure is thus conducted to place the dominant poles of the dynamic system at desired locations on the s-plane so that the unstable dynamics, which is the required criterion for energy generation, is achieved. Next, the closed-loop poles are selected based on a desired frequency so that a periodical system is found. Consequently, the design parameters, including mass and spring stiffness for both power and displacer pistons, are obtained. Finally, the engine power is calculated through the proposed control-based analysis and the result is compared to those of the experimental work and the Beale number approach. The outcomes of this work clearly reveal the effectiveness of the control-based design technique of FPSEs compared to the well-known approaches such as Beale number.

  7. Generalised pole-placement control of steam turbine speed

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-del-Busto, R. [ITESM, Cuernavaca (Mexico). Div. de Ingenieria y Ciencias; Munoz, J. [ITESM, Xochimilco (Mexico). Div. de Ingenieria y Ciencias

    1996-12-31

    An application of a pole-placement self-tuning predictive control algorithm is developed to regulate speed of a power plant steam turbine model. Two types of system representation (CARMA and CARIMA) are used to test the control algorithm. Simulation results show that when using a CARMA model better results are produced. Two further comparisons are made when using a PI controller and a generalised predictive controller. (author)

  8. Pole placement algorithm for control of civil structures subjected to earthquake excitation

    Directory of Open Access Journals (Sweden)

    Nikos Pnevmatikos

    2017-04-01

    Full Text Available In this paper the control algorithm for controlled civil structures subjected to earthquake excitation is thoroughly investigated. The objective of this work is the control of structures by means of the pole placement algorithm, in order to improve their response against earthquake actions. Successful application of the algorithm requires judicious placement of the closed-loop eigenvalues from the part of the designer. The pole placement algorithm was widely applied to control mechanical systems. In this paper, a modification in the mathematical background of the algorithm in order to be suitable for civil fixed structures is primarily presented. The proposed approach is demonstrated by numerical simulations for the control of both single and multi-degree of freedom systems subjected to seismic actions. Numerical results have shown that the control algorithm is efficient in reducing the response of building structures, with small amount of required control forces.

  9. Pole-placement Predictive Functional Control for under-damped systems with real numbers algebra.

    Science.gov (United States)

    Zabet, K; Rossiter, J A; Haber, R; Abdullah, M

    2017-11-01

    This paper presents the new algorithm of PP-PFC (Pole-placement Predictive Functional Control) for stable, linear under-damped higher-order processes. It is shown that while conventional PFC aims to get first-order exponential behavior, this is not always straightforward with significant under-damped modes and hence a pole-placement PFC algorithm is proposed which can be tuned more precisely to achieve the desired dynamics, but exploits complex number algebra and linear combinations in order to deliver guarantees of stability and performance. Nevertheless, practical implementation is easier by avoiding complex number algebra and hence a modified formulation of the PP-PFC algorithm is also presented which utilises just real numbers while retaining the key attributes of simple algebra, coding and tuning. The potential advantages are demonstrated with numerical examples and real-time control of a laboratory plant. Copyright © 2017 ISA. All rights reserved.

  10. Multivariable robust control of an air-handling unit: A comparison between pole-placement and H∞ controllers

    International Nuclear Information System (INIS)

    Moradi, Hamed; Bakhtiari-Nejad, Firooz; Saffar-Avval, Majid

    2012-01-01

    Highlights: ► Robust control of a multivariable air-handling unit (AHU). ► Controllers designed based on pole-placement and μ-synthesis. ► Robust performance in the presence of model uncertainties. ► Achievement of various tracking objectives in temperature and relative humidity. ► Comfort conditions in buildings with low energy consumption and operation cost. - Abstract: Control of air-conditioner units is essential to achieve satisfactory comfort conditions in buildings while keeping low energy consumption and operation costs. In this paper, a nonlinear multiinput and multioutput model (MIMO) of an air-handling unit (AHU) is considered. After linearization of the state equations around the operating points, an observer and a regulator are designed for the estimation of state variables and disturbance rejection, respectively. A realistic uncertain model is considered which constitutes various uncertainties associated with complex nonlinear model of AHU. In the presence of model uncertainties, a H ∞ -robust controller is designed to guarantee robust performance of the air-handling unit. In addition, a simple controller based on pole-placement approach is developed. Indoor temperature and relative humidity are controlled via manipulation of valve positions of air and cold water flow rates. Achievement of tracking objectives is investigated through various desired commands of indoor temperature and relative humidity (including a sequence of steps and ramps-steps). According to results, the H ∞ -robust controller guarantees the robust performance of the AHU in tracking of desired set-paths (while using the simple pole-placement controller leads to high oscillatory behavior of the output variables and control efforts). Moreover, using H ∞ -robust controller results in less energy consumption in comparison with the pole-placement controller.

  11. Groebner Basis Solutions to Satellite Trajectory Control by Pole Placement

    Science.gov (United States)

    Kukelova, Z.; Krsek, P.; Smutny, V.; Pajdla, T.

    2013-09-01

    Satellites play an important role, e.g., in telecommunication, navigation and weather monitoring. Controlling their trajectories is an important problem. In [1], an approach to the pole placement for the synthesis of a linear controller has been presented. It leads to solving five polynomial equations in nine unknown elements of the state space matrices of a compensator. This is an underconstrained system and therefore four of the unknown elements need to be considered as free parameters and set to some prior values to obtain a system of five equations in five unknowns. In [1], this system was solved for one chosen set of free parameters with the help of Dixon resultants. In this work, we study and present Groebner basis solutions to this problem of computation of a dynamic compensator for the satellite for different combinations of input free parameters. We show that the Groebner basis method for solving systems of polynomial equations leads to very simple solutions for all combinations of free parameters. These solutions require to perform only the Gauss-Jordan elimination of a small matrix and computation of roots of a single variable polynomial. The maximum degree of this polynomial is not greater than six in general but for most combinations of the input free parameters its degree is even lower. [1] B. Palancz. Application of Dixon resultant to satellite trajectory control by pole placement. Journal of Symbolic Computation, Volume 50, March 2013, Pages 79-99, Elsevier.

  12. Dominant pole placement with fractional order PID controllers: D-decomposition approach.

    Science.gov (United States)

    Mandić, Petar D; Šekara, Tomislav B; Lazarević, Mihailo P; Bošković, Marko

    2017-03-01

    Dominant pole placement is a useful technique designed to deal with the problem of controlling a high order or time-delay systems with low order controller such as the PID controller. This paper tries to solve this problem by using D-decomposition method. Straightforward analytic procedure makes this method extremely powerful and easy to apply. This technique is applicable to a wide range of transfer functions: with or without time-delay, rational and non-rational ones, and those describing distributed parameter systems. In order to control as many different processes as possible, a fractional order PID controller is introduced, as a generalization of classical PID controller. As a consequence, it provides additional parameters for better adjusting system performances. The design method presented in this paper tunes the parameters of PID and fractional PID controller in order to obtain good load disturbance response with a constraint on the maximum sensitivity and sensitivity to noise measurement. Good set point response is also one of the design goals of this technique. Numerous examples taken from the process industry are given, and D-decomposition approach is compared with other PID optimization methods to show its effectiveness. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Digital PI-PD controller design for arbitrary order systems: Dominant pole placement approach.

    Science.gov (United States)

    Dincel, Emre; Söylemez, Mehmet Turan

    2018-05-02

    In this paper, a digital PI-PD controller design method is proposed for arbitrary order systems with or without time-delay to achieve desired transient response in the closed-loop via dominant pole placement approach. The digital PI-PD controller design problem is solved by converting the original problem to the digital PID controller design problem. Firstly, parametrization of the digital PID controllers which assign dominant poles to desired location is done. After that the subset of digital PID controller parameters in which the remaining poles are located away from the dominant pole pair is found via Chebyshev polynomials. The obtained PID controller parameters are then transformed into the PI-PD controller parameters by considering the closed-loop controller zero and the design is completed. Success of the proposed design method is firstly demonstrated on an example transfer function and compared with the well-known PID controller methods from the literature through simulations. After that the design method is implemented on the fan and plate laboratory system in a real environment. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  14. The design of multi-lead-compensators for stabilization and pole placement in double-integrator networks

    NARCIS (Netherlands)

    Wan, Yan; Roy, Sandip; Saberi, Ali; Stoorvogel, Antonie Arij

    2010-01-01

    We study decentralized controller design for stabilization and pole-placement, in a network of autonomous agents with double-integrator internal dynamics and arbitrary observation topology. We show that a simple multi-lead-compensator architecture, in particular one in which each agent uses a

  15. Robot-assisted laparoscopic pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis: Variations in double-J ureteral stenting techniques.

    Science.gov (United States)

    Baek, Minki; Au, Jason; Huang, Gene O; Koh, Chester J

    2017-04-01

    We describe our experience with robot-assisted laparoscopic (RAL) pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis with an emphasis on the various double J (DJ) ureteral stent placement techniques. We used our RAL pyeloureterostomy technique in two female infants with duplex systems and upper pole hydronephrosis. For case 1, we introduced the DJ stent and placed it in the recipient lower pole ureter during the robotic operation in an antegrade fashion. For case 2, we inserted the DJ stent during retrograde pyelography prior to the robotic procedure in a retrograde fashion, and the proximal portion of the stent was placed across the anastomosis into the upper pole renal pelvis. Postoperatively, each of the patients were discharged on postoperative day 1 without complications. The postoperative renal ultrasound at 3 months demonstrated marked improvement of the right upper pole hydronephrosis in both patients. RAL pyeloureterostomy represents a minimally invasive option for upper tract reconstruction of duplex systems with upper pole hydronephrosis in infants. The DJ stent can be placed at the beginning or during the procedure. The stent can be placed in the lower pole ureter or across the anastomosis into the upper pole renal pelvis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  16. The design of multi-lead-compensators for stabilization and pole placement in double-integrator networks under saturation

    NARCIS (Netherlands)

    Wan, Yan; Roy, Sandip; Saberi, Ali; Stoorvogel, Antonie Arij

    2009-01-01

    We study decentralized controller design for stabilization and pole-placement, in a network of autonomous agents with double-integrator internal dynamics and arbitrary observation topology. We show that a simple multi-lead-compensator architecture, in particular one in which each agent uses a

  17. DECOUPLING CONTROL OF TITO SYSTEM SUPPORTED BY DOMINANT POLE PLACEMENT METHOD

    Directory of Open Access Journals (Sweden)

    Novak N. Nedić

    2017-08-01

    Full Text Available Appropriate approach to the nature of systems is a significant precondition for its successful control. An always actual issue of its mutual coupling is considered in this paper. A multivariable system with two-inputs and two-outputs (TITO is in the focus here. The dominant pole placement method is used in trying to tune the PID controllers that should support the decoupling control. The aim is to determine parameters of the PID controllers which, in combination with decoupler, can obtain a good dynamical behavior of the system. Therefore, this kind of the centralized analytically obtained controller is used for object control. Another goal is to simplify the tuning procedure of PID controllers and enlarge the possibility for introducing the given approach into practice. But the research results indicate that the proposed procedure leads to the usage of P controllers because they enable the best performances for the considered object. Also, it is noticed that some differences from the usual rules in selection of the dominant poles gives better results. The research is supported by simulations and, therefore, the proposed method effectiveness, regarding the system behavior quality, is presented on several examples.

  18. Robust ℋ∞ Dynamic Output Feedback Control Synthesis with Pole Placement Constraints for Offshore Wind Turbine Systems

    Directory of Open Access Journals (Sweden)

    Tore Bakka

    2012-01-01

    Full Text Available The problem of robust ℋ∞ dynamic output feedback control design with pole placement constraints is studied for a linear parameter-varying model of a floating wind turbine. A nonlinear model is obtained and linearized using the FAST software developed for wind turbines. The main contributions of this paper are threefold. Firstly, a family of linear models are represented based on an affine parameter-varying model structure for a wind turbine system. Secondly, the bounded parameter-varying parameters are removed using upper bounded inequalities in the control design process. Thirdly, the control problem is formulated in terms of linear matrix inequalities (LMIs. The simulation results show a comparison between controller design based on a constant linear model and a controller design for the linear parameter-varying model. The results show the effectiveness of our proposed design technique.

  19. A conformal mapping based fractional order approach for sub-optimal tuning of PID controllers with guaranteed dominant pole placement

    Science.gov (United States)

    Saha, Suman; Das, Saptarshi; Das, Shantanu; Gupta, Amitava

    2012-09-01

    A novel conformal mapping based fractional order (FO) methodology is developed in this paper for tuning existing classical (Integer Order) Proportional Integral Derivative (PID) controllers especially for sluggish and oscillatory second order systems. The conventional pole placement tuning via Linear Quadratic Regulator (LQR) method is extended for open loop oscillatory systems as well. The locations of the open loop zeros of a fractional order PID (FOPID or PIλDμ) controller have been approximated in this paper vis-à-vis a LQR tuned conventional integer order PID controller, to achieve equivalent integer order PID control system. This approach eases the implementation of analog/digital realization of a FOPID controller with its integer order counterpart along with the advantages of fractional order controller preserved. It is shown here in the paper that decrease in the integro-differential operators of the FOPID/PIλDμ controller pushes the open loop zeros of the equivalent PID controller towards greater damping regions which gives a trajectory of the controller zeros and dominant closed loop poles. This trajectory is termed as "M-curve". This phenomena is used to design a two-stage tuning algorithm which reduces the existing PID controller's effort in a significant manner compared to that with a single stage LQR based pole placement method at a desired closed loop damping and frequency.

  20. Pole shifting with constrained output feedback

    International Nuclear Information System (INIS)

    Hamel, D.; Mensah, S.; Boisvert, J.

    1984-03-01

    The concept of pole placement plays an important role in linear, multi-variable, control theory. It has received much attention since its introduction, and several pole shifting algorithms are now available. This work presents a new method which allows practical and engineering constraints such as gain limitation and controller structure to be introduced right into the pole shifting design strategy. This is achieved by formulating the pole placement problem as a constrained optimization problem. Explicit constraints (controller structure and gain limits) are defined to identify an admissible region for the feedback gain matrix. The desired pole configuration is translated into an appropriate cost function which must be closed-loop minimized. The resulting constrained optimization problem can thus be solved with optimization algorithms. The method has been implemented as an algorithmic interactive module in a computer-aided control system design package, MVPACK. The application of the method is illustrated to design controllers for an aircraft and an evaporator. The results illustrate the importance of controller structure on overall performance of a control system

  1. Adaptive robust pole-placement control of 4-leg voltage-source inverters for standalone photovoltaic systems: Considering digital delays

    International Nuclear Information System (INIS)

    Nasiri, Reza; Radan, Ahmad

    2011-01-01

    Three leg inverters for photovoltaic systems have a lot of disadvantages, especially when the load is unbalanced. These disadvantages are for example, small utilization of the DC link voltage, the dependency of the modulation factor of the load current and the superposition of a DC component with the output AC voltage. A solution for these problems is the 4-leg inverter. Most papers dealing with 4-leg inverters ignore the effect of digital delays in control loop and suggest classic controllers, such as PI controller. However, the transient performance of the system does not become adjustable by applying classic control techniques. Additionally, adaptive control techniques have not yet been discussed for 4-leg inverters. This paper proposes the pole-placement control strategy via state feedback with integral state, which is a modern control technique, to control the system. Consequently, resulted system becomes highly robust. In addition, it suggests a Self-Tuner Regulator to guarantee the adaptive performance of the final system. Moreover, it proposes a novel model, considering digital delays, for 4-leg inverters. Simulation results show that transient performance of the system becomes accurately adjustable and the 4-leg inverter generates balanced voltage, with sinusoidal waveform, in spite of the presence of RL time variant loads.

  2. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    International Nuclear Information System (INIS)

    Dasgupta, Niloy; Lungren, Matthew P.; Patel, Manish N.; Racadio, John M.; Johnson, Neil D.

    2016-01-01

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  3. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, Niloy; Lungren, Matthew P. [Lucile Packard Children' s Hospital Stanford, Department of Radiology, Palo Alto, CA (United States); Patel, Manish N.; Racadio, John M.; Johnson, Neil D. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-09-15

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  4. Post-placement temperature reduction techniques

    DEFF Research Database (Denmark)

    Liu, Wei; Nannarelli, Alberto

    2010-01-01

    With technology scaled to deep submicron era, temperature and temperature gradient have emerged as important design criteria. We propose two post-placement techniques to reduce peak temperature by intelligently allocating whitespace in the hotspots. Both methods are fully compliant with commercial...

  5. Artificial Intelligence based technique for BTS placement

    Science.gov (United States)

    Alenoghena, C. O.; Emagbetere, J. O.; Aibinu, A. M.

    2013-12-01

    The increase of the base transceiver station (BTS) in most urban areas can be traced to the drive by network providers to meet demand for coverage and capacity. In traditional network planning, the final decision of BTS placement is taken by a team of radio planners, this decision is not fool proof against regulatory requirements. In this paper, an intelligent based algorithm for optimal BTS site placement has been proposed. The proposed technique takes into consideration neighbour and regulation considerations objectively while determining cell site. The application will lead to a quantitatively unbiased evaluated decision making process in BTS placement. An experimental data of a 2km by 3km territory was simulated for testing the new algorithm, results obtained show a 100% performance of the neighbour constrained algorithm in BTS placement optimization. Results on the application of GA with neighbourhood constraint indicate that the choices of location can be unbiased and optimization of facility placement for network design can be carried out.

  6. Artificial Intelligence based technique for BTS placement

    International Nuclear Information System (INIS)

    Alenoghena, C O; Emagbetere, J O; 1 Minna (Nigeria))" data-affiliation=" (Department of Telecommunications Engineering, Federal University of Techn.1 Minna (Nigeria))" >Aibinu, A M

    2013-01-01

    The increase of the base transceiver station (BTS) in most urban areas can be traced to the drive by network providers to meet demand for coverage and capacity. In traditional network planning, the final decision of BTS placement is taken by a team of radio planners, this decision is not fool proof against regulatory requirements. In this paper, an intelligent based algorithm for optimal BTS site placement has been proposed. The proposed technique takes into consideration neighbour and regulation considerations objectively while determining cell site. The application will lead to a quantitatively unbiased evaluated decision making process in BTS placement. An experimental data of a 2km by 3km territory was simulated for testing the new algorithm, results obtained show a 100% performance of the neighbour constrained algorithm in BTS placement optimization. Results on the application of GA with neighbourhood constraint indicate that the choices of location can be unbiased and optimization of facility placement for network design can be carried out

  7. Poling of Planar Silica Waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Kristensen, Martin; Jensen, Jesper Bo

    1999-01-01

    UV-written planar silica waveguides are poled using two different poling techniques, thermal poling and UV-poling. Thermal poling induces an electro-optic coefficient of 0.067 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. The induced electro-optic effect shows a linear dependence...

  8. A moving pole-placement compensation design method to increase the bandwidth of RC-damper-based dual “Buck-Boost” AC/DC converter

    DEFF Research Database (Denmark)

    Wu, Weimin; Qin, Weibo; Wang, Houqin

    2017-01-01

    the “Buck” mode, the control-to-grid current transfer function of this dual “Buck-Boost” AC/DC converter has a movable zero, which is related to the input power and the output DC voltage. When the input power increases, the movable zero will slide to the lower frequency range. And then, the gain between...... the cut-off frequency point and the resonant frequency of LCL filter will swell up, resulting in reduced amplitude margin and suppressed bandwidth of system. Based on the theoretical analysis, a new dynamic pole placement compensation control design method is proposed for this dual AC/DC converter...

  9. Stabilization Using a Discrete Fuzzy PDC Control with PID Controllers and Pole Placement: Application to an Experimental Greenhouse

    Directory of Open Access Journals (Sweden)

    Amine Chouchaine

    2011-01-01

    Full Text Available This paper proposes a control strategy for complex and nonlinear systems, based on a parallel distributed compensation (PDC controller. A solution is presented to solve a stability problem that arises when dealing with a Takagi-Sugeno discrete system with great numbers of rules. The PDC controller will use a classical controller like a PI, PID, or RST in each rule with a pole placement strategy to avoid causing instability. The fuzzy controller presented combines the multicontrol approach and the performance of the classical controllers to obtain a robust nonlinear control action that can also deal with time-variant systems. The presented method was applied to a small greenhouse to control its inside temperature by variation in ventilation rate inside the process. The results obtained will show the efficiency of the adopted method to control the nonlinear and complex systems.

  10. Influence of Bipolar Pulse Poling Technique for Piezoelectric Vibration Energy Harvesters using Pb(Zr,Ti)O3 Films on 200 mm SOI Wafers

    International Nuclear Information System (INIS)

    Moriwaki, N; Fujimoto, K; Suzuki, K; Kobayashi, T; Itoh, T; Maeda, R; Suzuki, Y; Makimoto, N

    2013-01-01

    Piezoelectric vibration energy harvester arrays using Pb(Zr,Ti)O 3 thin films on 200 mm SOI wafers were fabricated. In-plane distribution of influence of bipolar pulse poling technique on direct current (DC) power output from the harvesters was investigated. The results indicate that combination poling treatment of DC and bipolar pulse poling increases a piezoelectric property and reduces a dielectric constant. It means that this poling technique improves the figure of merit of sensors and harvesters. Maximum DC power from a harvester treated by DC poling after bipolar pulse poling is about five times larger than a one treated by DC poling only

  11. PI controller design of a wind turbine: evaluation of the pole-placement method and tuning using constrained optimization

    DEFF Research Database (Denmark)

    Mirzaei, Mahmood; Tibaldi, Carlo; Hansen, Morten Hartvig

    2016-01-01

    to automatically tune the wind turbine controller subject to robustness constraints. The properties of the system such as the maximum sensitivity and complementary sensitivity functions (Ms and Mt), along with some of the responses of the system, are used to investigate the controller performance and formulate...... the optimization problem. The cost function is the integral absolute error (IAE) of the rotational speed from a disturbance modeled as a step in wind speed. Linearized model of the DTU 10-MW reference wind turbine is obtained using HAWCStab2. Thereafter, the model is reduced with model order reduction. The trade......PI/PID controllers are the most common wind turbine controllers. Normally a first tuning is obtained using methods such as pole-placement or Ziegler-Nichols and then extensive aeroelastic simulations are used to obtain the best tuning in terms of regulation of the outputs and reduction of the loads...

  12. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  13. FtsZ placement in nucleoid-free bacteria.

    Directory of Open Access Journals (Sweden)

    Manuel Pazos

    Full Text Available We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO. A second septum placement mechanism, the MinCDE system (Min involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*, a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement.

  14. FtsZ placement in nucleoid-free bacteria.

    Science.gov (United States)

    Pazos, Manuel; Casanova, Mercedes; Palacios, Pilar; Margolin, William; Natale, Paolo; Vicente, Miguel

    2014-01-01

    We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO). A second septum placement mechanism, the MinCDE system (Min) involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*), a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement.

  15. Wound complications after chemo-port placement in children: Does closure technique matter?

    Science.gov (United States)

    Muncie, Colin; Herman, Richard; Collier, Anderson; Berch, Barry; Blewett, Christopher; Sawaya, David

    2018-03-01

    Wound dehiscence after chemo-port placement is a rare but potentially significant complication. We hypothesize that by using a simple running skin closure technique during chemo-port placement the rate of wound dehiscence and overall wound complications can be significantly decreased. IRB approval was obtained and patients port from June 2012 to April 2016 were analyzed. Data collected on patients included patient demographics, skin closure type, and wound complications within 30days. Chi-square was performed to examine the univariate association with skin closure technique and wound dehiscence. Logistic regression was performed to examine the multivariable association between skin closure type and wound dehiscence and to compute odds ratios. There were 259 ports placed in this cohort: 125 used simple running skin closure technique, and 134 used the subcuticular skin closure. Patients were found to not have any difference in rate of dehiscence or overall wound complications based on gender, age, location of port, or use of steroids or chemotherapy within 1week of port placement. When compared, only 1 case (0.80%) in the simple running group vs 10 cases (7.46%) in the subcuticular group experienced a wound dehiscence [unadjusted OR=14.07 (1.69, 116.99) p=0.0144]. When comparing overall wound complications the simple running group had 3 (2.4%) versus 12 (8.96%) in the subcuticular group [unadjusted OR=4.78 (1.27, 17.94) p=0.0203]. When adjusting for port-number both dehiscence and overall wound complications remained statistically significant. We conclude that the simple running skin closure for chemo-port placement in children has superior outcomes in regards to prevention of dehiscence and overall wound related complications when compared to the subcuticular technique. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Virtual planning of dental implant placement using CT double scan-technique - own experience

    International Nuclear Information System (INIS)

    Wojciechowski, W.; Urbanik, A.; Kownacki, P.; Kownacki, S.

    2007-01-01

    The correctness of CT performed with the use of a double-scan technique is the basis for achieving proper quality of 3D reconstructions of the maxilla or mandible and subsequent virtual planning of dental implant placement. The aim of this study was the presentation of the methodology of computed tomography scanning and own experience with the use of the double-scan technique. The study group included 26 individuals who underwent MDCT with a double-scan technique using a MDCT scanner SOMATOM Sensation (Siemens, Germany). The parameters of the examination: slice-collimation 10 x 0.75 mm, slice-thickness 0.75 mm. The first CT scan in the procedure was the scan of the patient wearing a radiological prosthesis and occlusal index, which was followed by a separate scan of the radiological prosthesis. These two CT scans were copied and transferred to PC with Procera Software program (Nobel Biocare, Sweden) where dental implant placement was virtually planned. In all 26 patients, precise three-dimensional reconstructions of the anatomical structure were obtained. In 11 patients, on the basis of the virtual planning, the implant placement was performed, 5 patients were referred to preparatory procedures, that is, restoration of the alveolar process, otolaryngological treatment of the maxillary sinuses. The remaining 10 patients did not qualify to the procedure because of unfavorable anatomical ideation's. Correct computed tomography with double-scan technique enables virtual planning of dental implant placement, on the basis of which the real procedure of implantation can be performed. (author)

  17. Placement of replace select Ti-Unite-coated type implants using a combination of immediate and submerge techniques after tooth extraction

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-06-01

    Full Text Available The high success rate of immediate implant placement both in the anterior and posterior regions were reported by many authors, therefore applying this techniques can be considered as a safe surgical procedure and minimizing the dental office visit for patient satisfaction. This paper reports the outcome of immediate placement of implants following extraction of anterior maxillary teeth. Combination technique of immediate and submerge implant placements including bone grafting procedure were used. Four implants with TiUnite surface type were placed immediately in two patients with the short-term result indicated that this technique may serve as a simple and safe procedure for immediate implant placement. It was concluded that immediate implant placement technique combined with TiUnite implant surface was successful in treating region directly after tooth extraction therefore this technique can be use as an alternative surgical method for dental implant rehabilitation.

  18. Design, parametrization, and pole placement of stabilizing output feedback compensators via injective cogenerator quotient signal modules.

    Science.gov (United States)

    Blumthaler, Ingrid; Oberst, Ulrich

    2012-03-01

    Control design belongs to the most important and difficult tasks of control engineering and has therefore been treated by many prominent researchers and in many textbooks, the systems being generally described by their transfer matrices or by Rosenbrock equations and more recently also as behaviors. Our approach to controller design uses, in addition to the ideas of our predecessors on coprime factorizations of transfer matrices and on the parametrization of stabilizing compensators, a new mathematical technique which enables simpler design and also new theorems in spite of the many outstanding results of the literature: (1) We use an injective cogenerator signal module ℱ over the polynomial algebra [Formula: see text] (F an infinite field), a saturated multiplicatively closed set T of stable polynomials and its quotient ring [Formula: see text] of stable rational functions. This enables the simultaneous treatment of continuous and discrete systems and of all notions of stability, called T-stability. We investigate stabilizing control design by output feedback of input/output (IO) behaviors and study the full feedback IO behavior, especially its autonomous part and not only its transfer matrix. (2) The new technique is characterized by the permanent application of the injective cogenerator quotient signal module [Formula: see text] and of quotient behaviors [Formula: see text] of [Formula: see text]-behaviors B. (3) For the control tasks of tracking, disturbance rejection, model matching, and decoupling and not necessarily proper plants we derive necessary and sufficient conditions for the existence of proper stabilizing compensators with proper and stable closed loop behaviors, parametrize all such compensators as IO behaviors and not only their transfer matrices and give new algorithms for their construction. Moreover we solve the problem of pole placement or spectral assignability for the complete feedback behavior. The properness of the full feedback behavior

  19. A Technique for Resecting Occipital Pole Gliomas Using a Keyhole Lobectomy.

    Science.gov (United States)

    Conner, Andrew K; Baker, Cordell M; Briggs, Robert G; Burks, Joshua D; Glenn, Chad A; Smitherman, Adam D; Morgan, Jake P; Pittman, Nathan A; Sughrue, Michael E

    2017-10-01

    Our purpose is to describe a method of resecting occipital pole gliomas through a keyhole lobectomy and share the patient outcomes of this technique. We performed a retrospective review of data obtained on all patients who underwent resection of occipital pole gliomas by the senior author between 2012 and 2016. We describe our technique for resecting these tumors using a keyhole lobectomy and share the patient outcomes of this operation. Eight patients were included in this study. Four patients (50%) had not received previous surgery. One patient (13%) was diagnosed with a World Health Organization grade II tumor, and 7 patients (88%) were diagnosed with glioblastoma. Two tumors (25%) were left sided and 6 (75%) right sided. The median size of resection was 28 cm 3 . The median extent of resection was 96%, and at least 90% of the tumor was resected in all cases. None of the patients experienced permanent postoperative complications. Temporary neurologic complications included 3 patients (38%) with encephalopathy and 1 patient (13%) with aphasia. There were no neurosurgical complications. Our study provides details on the technical aspects of occipital keyhole lobectomies and gives the outcomes of patients who have received an operation for tumors in this uncommon location. Taking white matter tract anatomy into consideration, we show that the keyhole method can be applied to gliomas of the occipital lobe. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Two-stage implant placement technique for the management of irradiated jaws: An animal study.

    Science.gov (United States)

    Aboushelib, Moustafa N; Arnaout, Mohamed A; Elsafi, Mohamed H; Kassem, Youssef M

    2017-10-01

    Radiotherapy results in diminished bone remodeling capacity and an elevated risk of osteoradionecrosis, which can negatively influence the survival rate of dental implants. Patients receiving radiotherapy are advised not to receive dental implants during or soon after completing their radiotherapy. The purpose of this animal study was to investigate a 2-stage implant placement technique designed to diminish applied trauma on irradiated bone. Two groups of white New Zealand rabbits received radiotherapy in ascending doses (2, 4, 8 Gy), while a nonirradiated group served as control. Three weeks after completion of the last radiotherapy session, one of the irradiated groups and the control group received titanium dental implants bilaterally in the femur head. For the second irradiated group, an osteotomy was performed, and the surgical wound was left to heal for 2 weeks before implant placement. All animals were sacrificed 4 weeks after implant placement, and histomorphometric analysis was used to study bone-implant contact (n=14, α=.05). Statistical analysis revealed significantly higher (F=159, P<.001) bone-implant contact in the 2-stage (40.2 ±1.9) implant placement technique than in the immediately placed implants (21.2 ±2.3) in irradiated bone. Both of the groups had a significantly lower bone-to-implant contact ratio than the non-irradiated control (64.2 ±3.8). Within the limitations of this animal study, the 2-stage implant placement technique could be used to reduce trauma in irradiated bone and to improve wound healing around dental implants. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Second-harmonic imaging of poled silica waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Pedersen, Kjeld; Bozhevolnyi, Sergey I.

    2000-01-01

    Electric-field poled silica-based waveguides are characterized by measurements of second-harmonic generation (SHG) and of the linear electro-optic effect (LEO). A SHG scanning technique allowing for high-resolution imaging of poled devices is demonstrated. Scans along the direction of the poling...

  2. Fracture Resistance of Premolars Restored by Various Types and Placement Techniques of Resin Composites

    Directory of Open Access Journals (Sweden)

    Horieh Moosavi

    2012-01-01

    Full Text Available To verify the fracture resistance of premolars with mesioocclusodistal preparations restored by different resin composites and placement techniques. Sixty premolars were randomly divided into two groups based on type of composite resin: Filtek P60 or Nulite F, and then each group was separated into three subgroups: bulk, centripetal, and fiber insert according to the type of placement method (n=10. Single-bond adhesive system was used as composite bonding according to the manufacturer's instructions. Specimens were restored in Groups 1, 2, and 3 with Filtek P60 and in Groups 4, 5, and 6 with Nulite F. After being stored 24 hours at 37∘C, a 4 mm diameter steel sphere in a universal testing machine was applied on tooth buccal and lingual cusps at a cross-head speed of 5 mm/min until fracture occurred. Groups 3 and 6 showed higher fracture resistance than Groups 1, 2, 4, and 5. Among the placement techniques, the fiber insert method had a significant effect, but the type of composite was ineffective. The insertion technique in contrast to the type of material had a significant influence on the fracture resistance of premolar teeth.

  3. Division site selection in Escherichia coli involves dynamic redistribution of Min proteins within coiled structures that extend between the two cell poles

    Science.gov (United States)

    Shih, Yu-Ling; Le, Trung; Rothfield, Lawrence

    2003-06-01

    The MinCDE proteins of Escherichia coli are required for proper placement of the division septum at midcell. The site selection process requires the rapid oscillatory redistribution of the proteins from pole to pole. We report that the three Min proteins are organized into extended membrane-associated coiled structures that wind around the cell between the two poles. The pole-to-pole oscillation of the proteins reflects oscillatory changes in their distribution within the coiled structure. We also report that the E. coli MreB protein, which is required for maintaining the rod shape of the cell, also forms extended coiled structures, which are similar to the MreB structures that have previously been reported in Bacillus subtilis. The MreB and MinCDE coiled arrays do not appear identical. The results suggest that at least two functionally distinct cytoskeletal-like elements are present in E. coli and that structures of this type can undergo dynamic changes that play important roles in division site placement and possibly other aspects of the life of the cell.

  4. The effect of starting point placement technique on thoracic transverse process strength: an ex vivo biomechanical study

    Directory of Open Access Journals (Sweden)

    Burton Douglas C

    2010-07-01

    Full Text Available Abstract Background The use of thoracic pedicle screws in spinal deformity, trauma, and tumor reconstruction is becoming more common. Unsuccessful screw placement may require salvage techniques utilizing transverse process hooks. The effect of different starting point placement techniques on the strength of the transverse process has not previously been reported. The purpose of this paper is to determine the biomechanical properties of the thoracic transverse process following various pedicle screw starting point placement techniques. Methods Forty-seven fresh-frozen human cadaveric thoracic vertebrae from T2 to T9 were disarticulated and matched by bone mineral density (BMD and transverse process (TP cross-sectional area. Specimens were randomized to one of four groups: A, control, and three others based on thoracic pedicle screw placement technique; B, straightforward; C, funnel; and D, in-out-in. Initial cortical bone removal for pedicle screw placement was made using a burr at the location on the transverse process or transverse process-laminar junction as published in the original description of each technique. The transverse process was tested measuring load-to-failure simulating a hook in compression mode. Analysis of covariance and Pearson correlation coefficients were used to examine the data. Results Technique was a significant predictor of load-to-failure (P = 0.0007. The least squares mean (LS mean load-to-failure of group A (control was 377 N, group B (straightforward 355 N, group C (funnel 229 N, and group D (in-out-in 301 N. Significant differences were noted between groups A and C, A and D, B and C, and C and D. BMD (0.925 g/cm2 [range, 0.624-1.301 g/cm2] was also a significant predictor of load-to-failure, for all specimens grouped together (P P 0.05. Level and side tested were not found to significantly correlate with load-to-failure. Conclusions The residual coronal plane compressive strength of the thoracic transverse process

  5. Deep percolation in greenhouse-cultivated celery using the technique of subsurface film strips placement

    Directory of Open Access Journals (Sweden)

    Zhida Du

    2014-05-01

    Full Text Available To reduce the deep percolation during greenhouse vegetable cultivation, the technique of subsurface film strips placement was tested. Four treatments with two kinds of cross-sections (flat and U-shaped and two different spacings (10 cm and 40 cm of subsurface film strips were arranged in a greenhouse before planting celery. At the same time, a non-film treatment was arranged for comparison. Soil water content was measured and irrigation time was adjusted according to the soil water content. Evapotranspiration of celery during growth was calculated by the method of energy balance and the deep percolation was calculated by the equation of water balance. Deep percolation was reduced in all experimental treatments. Greater reduction in deep percolation was observed when using U-shaped cross-section strips compared with that using the flat cross-section strips. In addition, greater reduction in deep percolation was observed when the spacing between the film strips was smaller. The results of this test showed that the technique of subsurface film strips placement can reduce deep percolation and conserve irrigation water for greenhouse vegetables cultivation. However, the optimal layout variables for the use of the technique of subsurface film strips placement need further experimental and numerical analysis.

  6. Optimal pole shifting controller for interconnected power system

    International Nuclear Information System (INIS)

    Yousef, Ali M.; Kassem, Ahmed M.

    2011-01-01

    Research highlights: → Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. → Power system stabilizer was designed based on optimal pole shifting controller. → The system performances was tested through load disturbances at different operating conditions. → The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. → The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for shifting one real pole or two complex conjugate poles, respectively. This presented method yields a solution, which is optimal with respect to a quadratic performance index. The attractive feature of this method is that it enables solutions of the complex problem to be easily found without solving any non-linear algebraic Riccati equation. The present power system stabilizer is based on Riccati equation approach. The control law depends on finding the feedback gain matrix, and then the control signal is synthesized by multiplying the state variables of the power system with determined gain matrix. The gain matrix is calculated one time only, and it works over wide range of operating conditions. To validate the power of the proposed PSS, a linearized model of a simple power system consisted of a single synchronous machine connected to infinite bus bar through transmission line is simulated. The studied power system is subjected to various operating points and power system parameters changes.

  7. Optimal pole shifting controller for interconnected power system

    Energy Technology Data Exchange (ETDEWEB)

    Yousef, Ali M., E-mail: drali_yousef@yahoo.co [Electrical Eng. Dept., Faculty of Engineering, Assiut University (Egypt); Kassem, Ahmed M., E-mail: kassem_ahmed53@hotmail.co [Control Technology Dep., Industrial Education College, Beni-Suef University (Egypt)

    2011-05-15

    Research highlights: {yields} Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. {yields} Power system stabilizer was designed based on optimal pole shifting controller. {yields} The system performances was tested through load disturbances at different operating conditions. {yields} The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. {yields} The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for shifting one real pole or two complex conjugate poles, respectively. This presented method yields a solution, which is optimal with respect to a quadratic performance index. The attractive feature of this method is that it enables solutions of the complex problem to be easily found without solving any non-linear algebraic Riccati equation. The present power system stabilizer is based on Riccati equation approach. The control law depends on finding the feedback gain matrix, and then the control signal is synthesized by multiplying the state variables of the power system with determined gain matrix. The gain matrix is calculated one time only, and it works over wide range of operating conditions. To validate the power of the proposed PSS, a linearized model of a simple power system consisted of a single synchronous machine connected to infinite bus bar through transmission line is simulated. The studied power system is subjected to various operating points and power system parameters changes.

  8. Pole Shape Optimization of Permanent Magnet Synchronous Motors Using the Reduced Basis Technique

    Directory of Open Access Journals (Sweden)

    A. Jabbari

    2010-03-01

    Full Text Available In the present work, an integrated method of pole shape design optimization for reduction of torque pulsation components in permanent magnet synchronous motors is developed. A progressive design process is presented to find feasible optimal shapes. This method is applied on the pole shape optimization of two prototype permanent magnet synchronous motors, i.e., 4-poles/6-slots and 4-poles-12slots.

  9. [Implant placement in the aesthetic zone: the socket-shield-technique].

    Science.gov (United States)

    Lagas, L J; Pepplinkhuizen, J J F A A; Bergé, S J; Meijer, G J

    2015-01-01

    Following the extraction of an incisor in the maxilla, resorption of the -alveolar bone always occurs, especially on the buccal side. This often indicates that in the buccocervical area, insufficient bone is present to cover the dental implant. One treatment option is to carry out a bone transplant on the buccal side prior to or during the placement of the implant. An alternative way of supporting the buccocervical gingival is to leave the buccal part of the radixin situ, the so-called socket-shield technique. The results of this treatment for 16 consecutive patients were evaluated and revealed that the socket-shield technique produces good treatment results.

  10. Unraveling the nature of electric field- and stress- induced structural transformations in soft PZT by a new powder poling technique.

    Science.gov (United States)

    Kalyani, Ajay Kumar; V, Lalitha K; James, Ajit R; Fitch, Andy; Ranjan, Rajeev

    2015-02-25

    A 'powder-poling' technique was developed to study electric field induced structural transformations in ferroelectrics exhibiting a morphotropic phase boundary (MPB). The technique was employed on soft PZT exhibiting a large longitudinal piezoelectric response (d(33) ∼ 650 pC N(-1)). It was found that electric poling brings about a considerable degree of irreversible tetragonal to monoclinic transformation. The same transformation was achieved after subjecting the specimen to mechanical stress, which suggests an equivalence of stress and electric field with regard to the structural mechanism in MPB compositions. The electric field induced structural transformation was also found to be accompanied by a decrease in the spatial coherence of polarization.

  11. The blind pushing technique for peripherally inserted central catheter placement through brachial vein puncture.

    Science.gov (United States)

    Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol

    2018-03-01

    The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (pushing technique and primary brachial vein access is technically feasible and may represent an alternative to the conventional PICC placement technique, having low incidences of

  12. EFFECT OF PLACEMENT TECHNIQUES, FLOWABLE COMPOSITE , LINER AND FIBRE INSERTS ON MARGINAL MICROLEAKAGE OF CLASS II COMPOSITE RESTORATIONS

    Directory of Open Access Journals (Sweden)

    Anupriya

    2015-08-01

    Full Text Available AIM : T he aim of this study was to evaluate effect of placement techniques, flow able composite, and fiber inserts in marginal adaptation of class II composite restorations. MATERIALS AND METHODS : 120 class II box cavities were prepared on both mesial and distal surfaces of extracted human molars. The prepared teeth were randomly assigned to 6 groups : 1 bulk insertion . ( S ingle increment, 2 O blique incremental placement technique, 3 Centripetal incremental placement technique . 4 S plit horizontal incremental placement technique . 5 flow able composite as gingival increment 6 ribbond fiber insert in gingival increment . The preparations were restored with a total etch adhesive (Adper Single Bond, 3M ESPE and nano composite (Z350, 3M ESPE. Specimens were isola ted with nail varnish except for a 2 - mm - wide rim around the restoration and thermocycled (1,000 thermal cycles, 5°C/55°C; 30 - second dwell time. The specimens were immersed in a solution of 2% methylene blue dye for 24 hours. The teeth were sectioned longi tudinally, observed under stereomicroscope and evaluated for microleakage using an ordinal scale of 0 to 4. The microleakage scores obtained from gingival walls were analyzed with Kruskal - Wallis and Mann Whitney nonparametric tests. RESULTS: Among all plac ement techniques split incremental technique showed least microleakage scores . The group that used flowable composite liner did not show significant reduction in microleakage and group with fiber inserts showed significant decrease in microleakage scores. CONCLUSION : None of the techniques eliminated marginal microleakage in class II composite restorations . However, the split incremental technique and group with fiber inserts showed significantly lower microleakage at gingival margin when compared to other groups

  13. Design of a portable CAT scanner for utility pole inspection

    International Nuclear Information System (INIS)

    Miller, W.H.

    1986-01-01

    Work is under way at the University of Missouri, Columbia (UMC) to design, build, and test a portable computerized axial tomography (CAT) device for the nondestructive, field imaging of wooden utility poles. CAT is a well-established medical technology that has recently been applied to a number of industrial applications. Wooden utility poles are prone to rot and decay at ground level; current techniques to assess this loss of strength are relatively primitive, i.e., tapping the pole (hitting the pole with a hammer) or boring into the pole for samples and then testing inside the bore hole with an electrical pulse device. The accuracy in identifying poles needing replacement using these techniques is ∼ 70%. Since the cost of replacing a pole ranges from hundreds to thousands of dollars, an accurate, nondestructive method is needed. CAT can accurately image a wooden utility pole (since the size, density, and atomic elements of a pole are similar to the human head to torso), as was confirmed by imaging poles using the UMC nuclear engineering EMI-1010 medical scanner. Detailed images have been produced showing the ring structure of the wood and voids due to rot or decay. Images approaching this quality have also been produced on living trees using semiportable systems by other researchers

  14. Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.

    Science.gov (United States)

    Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai

    2014-01-01

    Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.

  15. A coil placement technique to treat intracranial aneurysm with incorporated artery.

    Science.gov (United States)

    Luo, Chao-Bao; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2018-03-01

    Endovascular coil embolization is an accepted treatment option for intracranial aneurysms. However, the coiling of aneurysms with an incorporated artery (IA) poses a high risk of IA occlusion. Here we report our experience of endovascular coil placement using a technique that avoids IA occlusion in aneurysms with IAs. Over a 6-year period, 185 patients harboring 206 intracranial aneurysms underwent endosaccular coiling. Forty-two of these patients with 45 aneurysms were treated by coil placement to avoid IAs occlusion. We assessed the anatomy of the aneurysms and IAs, technical feasibility of the procedure, and degree of aneurysm occlusion. Clinical and angiographic outcomes were assessed as well. Aneurysms were located in the supra-clinoid intracranial internal carotid artery (n = 24), anterior cerebral artery (n = 6), middle cerebral artery (n = 7), and vertebrobasilar artery (n = 8). The IA was at the aneurysm neck in 34 patients, body in 10, and dome in 1. Immediate post-coiling angiogram showed preservation of blood flow through the IA in all aneurysms. Coil compaction with aneurysmal regrowth was found in 7 of 36 patients having follow-up conventional angiography. One patient had an IA territory infarction after embolization. All 42 patients were followed up (mean: 21 months) and showed no re-bleeding. This technique is effective and safe in managing intracranial aneurysms with IAs. Although aneurysmal recurrence may occur in some aneurysms because of insufficient coiling, this technique is simpler to perform and requires less skill than other techniques. It can be an alternative option for treating some selected intracranial aneurysms with IAs. Copyright © 2017. Published by Elsevier Taiwan LLC.

  16. Force interaction and 3D pole movement in double poling.

    Science.gov (United States)

    Stöggl, T; Holmberg, H-C

    2011-12-01

    The aim of this study was to analyze double poling using combined kinetic and 3D kinematic analysis at high skiing speeds as regards pole force components, pole angles and pole behavior during the poling and swing phase. The hypothesis was that a horizontal pole force is more predictive for maximal skiing speed (V(max)) than the resultant pole force. Sixteen elite skiers performed a double-poling V(max) test while treadmill roller skiing. Pole forces and 3D kinematics of pole movement at a speed of 30 km/h were analyzed and related to V(max). The duration of the "preparation phase" showed the strongest relationship with V(max) (r=0.87, Pmax) compared with the resultant pole force. Impact force was not related to V(max). At high skiing speeds, skiers should aim to combine high pole forces with appropriate timing of pole forces and appropriate pole and body positions during the swing and poling phase. The emphasis in training should be on the development of specific strength capacities for pole force production and the utilization of these capacities in double-poling training sessions. © 2011 John Wiley & Sons A/S.

  17. Stent placement with the monorail technique for treatment of mesenteric artery stenosis.

    Science.gov (United States)

    Schaefer, Philipp J; Schaefer, Fritz K W; Hinrichsen, Holger; Jahnke, Thomas; Charalambous, Nikolas; Heller, Martin; Mueller-Huelsbeck, Stefan

    2006-04-01

    To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.

  18. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  19. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique.

    Science.gov (United States)

    Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.

  20. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  1. Geometric Modelling of Octagonal Lamp Poles

    Science.gov (United States)

    Chan, T. O.; Lichti, D. D.

    2014-06-01

    Lamp poles are one of the most abundant highway and community components in modern cities. Their supporting parts are primarily tapered octagonal cones specifically designed for wind resistance. The geometry and the positions of the lamp poles are important information for various applications. For example, they are important to monitoring deformation of aged lamp poles, maintaining an efficient highway GIS system, and also facilitating possible feature-based calibration of mobile LiDAR systems. In this paper, we present a novel geometric model for octagonal lamp poles. The model consists of seven parameters in which a rotation about the z-axis is included, and points are constrained by the trigonometric property of 2D octagons after applying the rotations. For the geometric fitting of the lamp pole point cloud captured by a terrestrial LiDAR, accurate initial parameter values are essential. They can be estimated by first fitting the points to a circular cone model and this is followed by some basic point cloud processing techniques. The model was verified by fitting both simulated and real data. The real data includes several lamp pole point clouds captured by: (1) Faro Focus 3D and (2) Velodyne HDL-32E. The fitting results using the proposed model are promising, and up to 2.9 mm improvement in fitting accuracy was realized for the real lamp pole point clouds compared to using the conventional circular cone model. The overall result suggests that the proposed model is appropriate and rigorous.

  2. Carrier Phase GPS Navigation to the North Pole

    Science.gov (United States)

    Moore, T.; Roberts, G. W.

    Over the last few years, on-the-fly integer ambiguity resolution for GPS has proven to be successful over short baselines (500 km. New techniques have been developed at the University of Nottingham to allow very long baseline integer ambiguity resolution, on-the-fly. A major problem with the use of carrier phase data is that posed by cycle slips. A technique for detecting and correcting cycle slips has been developed, and its use is discussed in this paper. The new technique has been proven through a series of trials, one of which included two flights to the North Pole, performing centimetric level positioning all the way to the pole. For many years, the GD Aero-Systems Course of the Air Warfare Centre based at RAF Cranwell executed a series of equipment flight trials to the North Pole, called the ARIES Flights. In May 1996, the authors were fortunate to take part in both flights, via Iceland and Greenland, to the North Pole. Based on reference stations at Thule Air Base, integer ambiguity resolution was accomplished, on-the-fly, and centimetric level navigation maintained throughout the flights. Earlier trials detailed in the paper demonstrate that the technique can resolve integer ambiguities on-the-fly within a few seconds over a baseline length of approximately 134 km, resulting in an accuracy of 12 cm. The majority of the residual error source for this being the ionosphere.

  3. Magnet pole tips

    Science.gov (United States)

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  4. Sphenoid dysplasia in neurofibromatosis type 1: a new technique for repair.

    Science.gov (United States)

    Concezio, Di Rocco; Amir, Samii; Gianpiero, Tamburrini; Luca, Massimi; Mario, Giordano

    2017-06-01

    Sphenoid bone dysplasia in neurofibromatosis type 1 is characterized by progressive exophthalmos and facial disfiguration secondary to herniation of meningeal and cerebral structures. We describe a technique for reconstruction of the sphenoid defect apt at preventing or correcting the ocular globe dislocation. After placement of spinal cerebrospinal fluid drainage to reduce intracranial pressure, the temporal pole is posteriorly dislocated extradurally. The greater sphenoid wing defect is identified. A titanium mesh covered by lyophilized dura, modeled in a curved fashion, is interposed between the bone defect and the cerebro-meningeal structures with its convex surface over the retracted temporal pole. The particular configuration of the titanium mesh allows a self-maintaining position due to the pressure exerted by the brain over its convex central part with its lateral margins consequently pushed and self-anchored against the medial and lateral walls of the temporal fossa. Screw fixation is not needed. The technique utilized in four cases proved to be reliable at the long-term clinical and neuroradiological controls (6 to 19 years). Sphenoid bone dysplasia in NF1, resulting in proptosis and exophthalmos, is usually progressive. It can be surgically repaired using a curved titanium mesh with the convexity faced to the temporal pole that is in the opposite fashion from all the techniques previously introduced. When utilized early in life, the technique can prevent the occurrence of the orbital and facial disfiguration.

  5. Effect of materials and manufacturing on the bending stiffness of vaulting poles

    Science.gov (United States)

    Davis, C. L.; Kukureka, S. N.

    2012-09-01

    The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP) composites. The lighter GFRP pole enabled the athletes to have a faster run-up, resulting in a greater take-off speed, giving them more kinetic energy to convert into potential energy and hence height. GFRP poles also have a much higher failure stress than bamboo, so the poles were engineered to bend under the load of the athlete, thereby storing elastic strain energy that can be released as the pole straightens, resulting in greater energy efficiency. The bending also allowed athletes to change their vaulting technique from a style that involved the body remaining almost upright during the vault to one where the athlete goes over the bar with their feet upwards. Modern vaulting poles can be made from GFRP and/or carbon fibre reinforced polymer (CFRP) composites. The addition of carbon fibres maintains the mechanical properties of the pole, but allows a reduction in the weight. The number and arrangement of the fibres determines the mechanical properties, in particular the bending stiffness. Vaulting poles are also designed for an individual athlete to take into account each athlete’s ability and physical characteristics. The poles are rated by ‘weight’ to allow athletes to select an appropriate pole for their ability. This paper will review the development of vaulting poles and the requirements to maximize performance. The properties (bending stiffness and pre-bend) and microstructure (fibre volume fraction and lay-up) of typical vaulting poles will be discussed. Originally published as Davis C L and Kukureka S N (2004) Effect of materials and manufacturing on the bending stiffness of vaulting poles The Engineering of

  6. The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Park, Sang Woo; Hwang, Dae Yong; Seong, Moo Kyung; Joh, Hee Kyung; Yoon, So Young; Cho, Yo Han; Choe, Won Hyeok [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-02-15

    We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4: mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon

  7. The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

    International Nuclear Information System (INIS)

    Chang, Il Soo; Park, Sang Woo; Hwang, Dae Yong; Seong, Moo Kyung; Joh, Hee Kyung; Yoon, So Young; Cho, Yo Han; Choe, Won Hyeok

    2011-01-01

    We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4: mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon

  8. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.

    Science.gov (United States)

    Yang, Xu; Wu, Qinfen; Lai, Chin-Hui; Wang, Xin

    2017-10-01

    We present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome. The patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1days (range, 2-12days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up. No patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29). The modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Variable Bone Density of Scaphoid: Importance of Subchondral Screw Placement.

    Science.gov (United States)

    Swanstrom, Morgan M; Morse, Kyle W; Lipman, Joseph D; Hearns, Krystle A; Carlson, Michelle G

    2018-02-01

    Background  Ideal internal fixation of the scaphoid relies on adequate bone stock for screw purchase; so, knowledge of regional bone density of the scaphoid is crucial. Questions/Purpose  The purpose of this study was to evaluate regional variations in scaphoid bone density. Materials and Methods  Three-dimensional CT models of fractured scaphoids were created and sectioned into proximal/distal segments and then into quadrants (volar/dorsal/radial/ulnar). Concentric shells in the proximal and distal pole were constructed in 2-mm increments moving from exterior to interior. Bone density was measured in Hounsfield units (HU). Results  Bone density of the distal scaphoid (453.2 ± 70.8 HU) was less than the proximal scaphoid (619.8 ± 124.2 HU). There was no difference in bone density between the four quadrants in either pole. In both the poles, the first subchondral shell was the densest. In both the proximal and distal poles, bone density decreased significantly in all three deeper shells. Conclusion  The proximal scaphoid had a greater density than the distal scaphoid. Within the poles, there was no difference in bone density between the quadrants. The subchondral 2-mm shell had the greatest density. Bone density dropped off significantly between the first and second shell in both the proximal and distal scaphoids. Clinical Relevance  In scaphoid fracture ORIF, optimal screw placement engages the subchondral 2-mm shell, especially in the distal pole, which has an overall lower bone density, and the second shell has only two-third the density of the first shell.

  10. Pressure transmitter surveillance: the dominant real pole case

    International Nuclear Information System (INIS)

    Blazquez, J.; Ballestrin, J.

    1995-01-01

    There are about 500 pressure transmitters in a nuclear power plant. Due to Safety requirements, some of them must be specially surveilled. Sensor response time to a pressure ramp is the usual quantity to be measured. Response time, τ r , reflects the dynamics of the sensor and the sensing line. A real pole is due to the inner sensor structure, but the complex pole stands for the sensing line too. The real pole usually is the dominant in most sensors. On line monitoring noise analysis regards simultaneously both, the sensor and the sensing line, but the noise signal contains not only the sensor poles, but many others coming from the plant, so must be conditioned previously and the determination of τ r is not free of systematic errors. That is the price to be paid for non disturbing the plant. When the real pole is dominant, the sensing line contribution is negligible, so the on line noise monitoring methods are supported by the laboratory experiments and the real pole border in the PSD is properly identified. The mean square frequency results proportional to τ r -1 , so manual techniques are designed for response time surveillance made by non noise plant's maintenance technicians. (author)

  11. Modeling FWM and impairments aware amplifiers placement technique for an optical MAN/WAN: Inline amplifiers case

    Science.gov (United States)

    Singh, Gurpreet; Singh, Maninder Lal

    2015-08-01

    A new four wave mixing (FWM) model for an optical network with amplifiers and a comparative analysis among three proposed amplifiers placement techniques have been presented in this paper. The FWM model is validated with the experimental measured data. The novelty of this model is its uniqueness that on direct substitutions of network parameters like length, it works even for unequal inter amplifier separations. The novelty of the analysis done among three schemes is that it presents fair choice of amplifiers placement methods for varied total system length. The appropriateness of these three schemes has been analyzed on the basis of critical system length, critical number of amplifiers and critical bit error rate (10-9) in presence of four wave mixing (FWM) and amplified spontaneous emission noise (ASE). The implementation of analysis done has been given with the help of an example of a regenerative metropolitan area network (MAN). The results suggest that the decreasing fiber section scheme should be avoided for placements of amplifiers and schemes IUFS and EFS shows their importance interchangeably for different set of parameters.

  12. Rotor Pole Shape Optimization of Permanent Magnet Brushless DC Motors Using the Reduced Basis Technique

    Directory of Open Access Journals (Sweden)

    GHOLAMIAN, A. S.

    2009-06-01

    Full Text Available In this paper, a magnet shape optimization method for reduction of cogging torque and torque ripple in Permanent Magnet (PM brushless DC motors is presented by using the reduced basis technique coupled by finite element and design of experiments methods. The primary objective of the method is to reduce the enormous number of design variables required to define the magnet shape. The reduced basis technique is a weighted combination of several basis shapes. The aim of the method is to find the best combination using the weights for each shape as the design variables. A multi-level design process is developed to find suitable basis shapes or trial shapes at each level that can be used in the reduced basis technique. Each level is treated as a separated optimization problem until the required objective is achieved. The experimental design of Taguchi method is used to build the approximation model and to perform optimization. This method is demonstrated on the magnet shape optimization of a 6-poles/18-slots PM BLDC motor.

  13. A Scapholunate Ligament-Sparing Technique Utilizing the Medial Femoral Condyle Corticocancellous Free Flap to Reconstruct Scaphoid Nonunions With Proximal Pole Avascular Necrosis.

    Science.gov (United States)

    Kazmers, Nikolas H; Thibaudeau, Stephanie; Levin, L Scott

    2016-09-01

    This article demonstrates a technique for the treatment of scaphoid fracture waist and proximal pole nonunions with avascular necrosis using a free vascularized medial femoral condyle flap. We present our surgical technique and representative case examples in which the scapholunate ligament, a key structure required to preserve carpal kinematics, is spared. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Repair and rehabilitation of wood utility poles with fibre-reinforced polymers

    Energy Technology Data Exchange (ETDEWEB)

    Polyzois, D.; Kell, J.A. [Manitoba Univ., Winnipeg, MB (Canada). Dept. of Civil Engineering

    2007-01-15

    In order to ensure safe and reliable service, all wood utility poles need an effective maintenance program. The service life of a wood utility pole depends on several factors, such as decay, mechanical damage, weathering, and changing design requirements. An effective preservative treatment and maintenance program can effectively extend the service life of the wood pole. However, all poles will attain a point when they are no longer suitable for their intended use. New innovative methods are therefore required to restore and maintain the structural integrity of existing wood poles, especially in light of the increasing cost of quality wood for use in poles as well as a result of environmental concerns regarding pole disposal and chemical treatment of existing poles. This article presented results from a research program carried out at the University of Manitoba to develop a repair and rehabilitation technique for wood poles using fibre-reinforced polymers (FRP). It also provided a brief overview of current standards for wood utility poles and reinforcing stubs and discussed the experimental program where long, air-dried jack pine poles were tested in order to evaluate the effectiveness of a proposed rehabilitation system consisting of FRP splines and FRP jackets. The ultimate capacity of the poles was determined using the CSA standard for wood poles. The capacity of the rehabilitated poles was nearly 93 per cent of the average ultimate capacity of the average ultimate capacity of poles tested during the first phase of the study, and 23 per cent higher than the capacity required by CSA standards. 7 refs., 2 figs., 4 tabs.

  15. Automated Fiber Placement of Advanced Materials (Preprint)

    National Research Council Canada - National Science Library

    Benson, Vernon M; Arnold, Jonahira

    2006-01-01

    .... ATK has been working with the Air Force Research Laboratory to foster improvements in the BMI materials and in the fiber placement processing techniques to achieve rates comparable to Epoxy placement rates...

  16. Analog integrated circuit design automation placement, routing and parasitic extraction techniques

    CERN Document Server

    Martins, Ricardo; Horta, Nuno

    2017-01-01

    This book introduces readers to a variety of tools for analog layout design automation. After discussing the placement and routing problem in electronic design automation (EDA), the authors overview a variety of automatic layout generation tools, as well as the most recent advances in analog layout-aware circuit sizing. The discussion includes different methods for automatic placement (a template-based Placer and an optimization-based Placer), a fully-automatic Router and an empirical-based Parasitic Extractor. The concepts and algorithms of all the modules are thoroughly described, enabling readers to reproduce the methodologies, improve the quality of their designs, or use them as starting point for a new tool. All the methods described are applied to practical examples for a 130nm design process, as well as placement and routing benchmark sets. Introduces readers to hierarchical combination of Pareto fronts of placements; Presents electromigration-aware routing with multilayer multiport terminal structures...

  17. Optimized baffle and aperture placement in neutral beamlines

    International Nuclear Information System (INIS)

    Stone, R.; Duffy, T.; Vetrovec, J.

    1983-01-01

    Most neutral beamlines contain an iron-core ion-bending magnet that requires shielding between the end of the neutralizer and this magnet. This shielding allows the gas pressure to drop prior to the beam entering the magnet and therefore reduces beam losses in this drift region. We have found that the beam losses can be reduced even further by eliminating the iron-core magnet and the magnetic shielding altogether. The required bending field can be supplied by current coils without the iron poles. In addition, placement of the baffles and apertures can affect the cold gas entering the plasma region and the losses in the neutral beam due to re-ionization. In our study we varied the placement of the baffles, which determine the amount of pumping in each chamber, and the apertures, which determine the beam loss. Our results indicate that a baffle/aperture configuration can be set for either minimum cold gas into the plasma region or minimum beam losses, but not both

  18. Iron Pole Shape Optimization of IPM Motors Using an Integrated Method

    Directory of Open Access Journals (Sweden)

    JABBARI, A.

    2010-02-01

    Full Text Available An iron pole shape optimization method to reduce cogging torque in Interior Permanent Magnet (IPM motors is developed by using the reduced basis technique coupled by finite element and design of experiments methods. Objective function is defined as the minimum cogging torque. The experimental design of Taguchi method is used to build the approximation model and to perform optimization. This method is demonstrated on the rotor pole shape optimization of a 4-poles/24-slots IPM motor.

  19. Placement of empty catheters for an HDR-emulating LDR prostate brachytherapy technique: comparison to standard intraoperative planning.

    Science.gov (United States)

    Niedermayr, Thomas R; Nguyen, Paul L; Murciano-Goroff, Yonina R; Kovtun, Konstantin A; Neubauer Sugar, Emily; Cail, Daniel W; O'Farrell, Desmond A; Hansen, Jorgen L; Cormack, Robert A; Buzurovic, Ivan; Wolfsberger, Luciant T; O'Leary, Michael P; Steele, Graeme S; Devlin, Philip M; Orio, Peter F

    2014-01-01

    We sought to determine whether placing empty catheters within the prostate and then inverse planning iodine-125 seed locations within those catheters (High Dose Rate-Emulating Low Dose Rate Prostate Brachytherapy [HELP] technique) would improve concordance between planned and achieved dosimetry compared with a standard intraoperative technique. We examined 30 consecutive low dose rate prostate cases performed by standard intraoperative technique of planning followed by needle placement/seed deposition and compared them to 30 consecutive low dose rate prostate cases performed by the HELP technique. The primary endpoint was concordance between planned percentage of the clinical target volume that receives at least 100% of the prescribed dose/dose that covers 90% of the volume of the clinical target volume (V100/D90) and the actual V100/D90 achieved at Postoperative Day 1. The HELP technique had superior concordance between the planned target dosimetry and what was actually achieved at Day 1 and Day 30. Specifically, target D90 at Day 1 was on average 33.7 Gy less than planned for the standard intraoperative technique but was only 10.5 Gy less than planned for the HELP technique (p 0.05). Placing empty needles first and optimizing the plan to the known positions of the needles resulted in improved concordance between the planned and the achieved dosimetry to the target, possibly because of elimination of errors in needle placement. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. Performance analysis of variable speed multiphase induction motor with pole phase modulation

    Directory of Open Access Journals (Sweden)

    Liu Huijuan

    2016-09-01

    Full Text Available The pole phase modulation (PPM technique is an effective method to extend speed range and torque capabilities for an integrated starter and hybrid electric vehicles applications. In this paper, the five pole-phase combination types of a multiphase induction motor (IM with 36 stator slots and 36 stator conductors are presented and compared quantitatively by using the time-stepping finite element method (TS-FEM. The 36 stator conductors of the proposed multiphase IM are fed by a 36 leg inverter and the current phase angle and amplitude of each stator conductor can be controlled independently. This paper focuses on the winding connection, the PPM technique and the performance comparative analysis of each pole-phase combination types of the proposed multiphase IM. The flux distribution, air-gap flux density, output torque, core losses and efficiency of five pole-phase combination types have been investigated.

  1. Sub-Coronal Inflatable Penile Prosthesis Placement With Modified No-Touch Technique: A Step-by-Step Approach With Outcomes.

    Science.gov (United States)

    Weinberg, Aaron C; Pagano, Matthew J; Deibert, Christopher M; Valenzuela, Robert J

    2016-02-01

    The surgical treatment of disorders of male sexual function requires specific exposure to correct the underlying problem safely and efficiently. Currently, sub-coronal exposure is used for treatment of phimosis, Peyronie's disease plaque (PDP), and semirigid penile prosthesis insertion. Infra-pubic and scrotal incisions are used for inflatable penile prosthesis (IPP) placement. However, men who present with several disorders might require multiple procedures and surgical incisions. To report a prospective review of our surgical experience and outcomes with a single sub-coronal incision for IPP placement with a modified no-touch technique. This approach allows for access to the entire corporal body for multiple reconstructive procedures. Two hundred men had IPPs placed through a sub-coronal incision using our modified no-touch technique. The penis was degloved to the level of the penoscrotal junction and the dartos muscle was everted and secured to the drapes. This allowed exclusion of the scrotal and penile skin from the operative field. After artificial erection, the patient's corpora were inspected for PDP and other abnormalities. Penoscrotal IPP models were placed in all cases with insertion proximal to the penoscrotal junction. After placement of the IPP, the abnormalities were repaired. Feasibility of the procedure, operative times, complication rate, utilization of accessory, reconstructive procedures, and post-operative penile length. Of the 200 men who had IPP placement, 92 had PDP that was treated, 106 (53%) consented to circumcision, 24 (12%) had their reservoir placed ectopically, and 31 (16%) had a prosthesis exchanged through the sub-coronal technique. Mean operative time was 73 minutes (39-161 minutes). Specialists in the surgical treatment of disorders of male sexual function can perform multiple procedures safely and easily through a modified no-touch single sub-coronal incision. This approach allows access to the entire corporal body, providing

  2. K.S. Micro-Implant Placement Guide

    OpenAIRE

    Sharma, K; Sangwan, A

    2014-01-01

    A one of the greatest concerns with orthodontic mini-implants is risk of injury to dental roots during placement is, especially when they are inserted between teeth. Many techniques have been used to facilitate safe placement of interradicular miniscrews. Brass Wires or metallic markers are easy to place in the interproximal spaces, but because their relative positions may be inconsistent in different radio -graphic views, they are not always accurate. K.S. micro implant placement guide sugge...

  3. Biomechanical pole and leg characteristics during uphill diagonal roller skiing.

    Science.gov (United States)

    Lindinger, Stefan Josef; Göpfert, Caroline; Stöggl, Thomas; Müller, Erich; Holmberg, Hans-Christer

    2009-11-01

    Diagonal skiing as a major classical technique has hardly been investigated over the last two decades, although technique and racing velocities have developed substantially. The aims of the present study were to 1) analyse pole and leg kinetics and kinematics during submaximal uphill diagonal roller skiing and 2) identify biomechanical factors related to performance. Twelve elite skiers performed a time to exhaustion (performance) test on a treadmill. Joint kinematics and pole/plantar forces were recorded separately during diagonal roller skiing (9 degrees; 11 km/h). Performance was correlated to cycle length (r = 0.77; P Push-off demonstrated performance correlations for impulse of leg force (r = 0.84), relative duration (r= -0.76) and knee flexion (r = 0.73) and extension ROM (r = 0.74). Relative time to peak pole force was associated with performance (r = 0.73). In summary, diagonal roller skiing performance was linked to 1) longer cycle length, 2) greater impulse of force during a shorter push-off with larger flexion/extension ROMs in leg joints, 3) longer leg swing, and 4) later peak pole force, demonstrating the major key characteristics to be emphasised in training.

  4. Domain wall width of lithium niobate poled during growth

    CERN Document Server

    Brooks, R; Hole, D E; Callejo, D; Bermudez, V; Diéguez, E

    2003-01-01

    Good quality crystals of periodically poled lithium niobate can be generated directly during growth. However, the temperature gradients at the zone boundaries define the width of the regions where the polarity is reversed. Hence, the region influenced the domain transition may be a significant fraction of the overall poling period for material poled during growth. Evidence for the scale of this feature is reported both by chemical etching and by the less common method of ion beam luminescence and the 'domain wall' width approximately 1 mu m for these analyses. The influence of the reversal region may differ for alternative techniques but the relevance to device design for second harmonic generation is noted.

  5. Biomechanical characteristics and speed adaptation during kick double poling on roller skis in elite cross-country skiers.

    Science.gov (United States)

    Göpfert, Caroline; Holmberg, Hans-Christer; Stöggl, Thomas; Müller, Erich; Lindinger, Stefan Josef

    2013-06-01

    Recent developments in cross-country ski racing should promote the use of kick double poling. This technique, however, has not been the focus in athletes' training and has barely been investigated. The aims of the present study were to develop a function-based phase definition and to analyse speed adaptation mechanisms for kick double poling in elite cross-country skiers. Joint kinematics and pole/plantar forces were recorded in 10 athletes while performing kick double poling at three submaximal roller skiing speeds. A speed increase was associated with increases in cycle length and rate, while absolute poling and leg push-off durations shortened. Despite maintained impulses of force, the peak and average pole/leg forces increased. During double poling and leg push-off, ranges of motion of elbow flexion and extension increased (p push-off showed high variability among elite skiers, thus illustrating important aspects for technique training.

  6. Highly efficient periodically poled KTP-isomorphs with large apertures and extreme domain aspect-ratios

    Science.gov (United States)

    Canalias, Carlota; Zukauskas, Andrius; Tjörnhamman, Staffan; Viotti, Anne-Lise; Pasiskevicius, Valdas; Laurell, Fredrik

    2018-02-01

    Since the early 1990's, a substantial effort has been devoted to the development of quasi-phased-matched (QPM) nonlinear devices, not only in ferroelectric oxides like LiNbO3, LiTaO3 and KTiOPO4 (KTP), but also in semiconductors as GaAs, and GaP. The technology to implement QPM structures in ferroelectric oxides has by now matured enough to satisfy the most basic frequency-conversion schemes without substantial modification of the poling procedures. Here, we present a qualitative leap in periodic poling techniques that allows us to demonstrate devices and frequency conversion schemes that were deemed unfeasible just a few years ago. Thanks to our short-pulse poling and coercive-field engineering techniques, we are able to demonstrate large aperture (5 mm) periodically poled Rb-doped KTP devices with a highly-uniform conversion efficiency over the whole aperture. These devices allow parametric conversion with energies larger than 60 mJ. Moreover, by employing our coercive-field engineering technique we fabricate highlyefficient sub-µm periodically poled devices, with periodicities as short as 500 nm, uniform over 1 mm-thick crystals, which allow us to realize mirrorless optical parametric oscillators with counter-propagating signal and idler waves. These novel devices present unique spectral and tuning properties, superior to those of conventional OPOs. Furthermore, our techniques are compatible with KTA, a KTP isomorph with extended transparency in the mid-IR range. We demonstrate that our highly-efficient PPKTA is superior both for mid-IR and for green light generation - as a result of improved transmission properties in the visible range. Our KTP-isomorph poling techniques leading to highly-efficient QPM devices will be presented. Their optical performance and attractive damage thresholds will be discussed.

  7. Can a Drill Guide Improve the Coracoid Graft Placement During the Latarjet Procedure? A Prospective Comparative Study With the Freehand Technique.

    Science.gov (United States)

    Barth, Johannes; Boutsiadis, Achilleas; Neyton, Lionel; Lafosse, Laurent; Walch, Gilles

    2017-10-01

    One of the factors that can affect the success of the Latarjet procedure is accurate coracoid graft (CG) placement. The use of a guide can improve placement of the CG and screw positioning in the sagittal and axial planes as compared with the classic open ("freehand") technique. Cohort study; Level of evidence, 2. A total of 49 patients who underwent a Latarjet procedure for the treatment of recurrent anterior shoulder instability were prospectively included; the procedure was performed with the freehand technique in 22 patients (group 1) and with use of a parallel drill guide during screw placement in 27 patients (group 2). All patients underwent a postoperative computed tomography scan with the same established protocol. The scans were used to evaluate and compare the position of the CG in the sagittal and axial planes, the direction of the screws (α angle), and overall contact of the graft with the anterior surface of the glenoid after the 2 surgical techniques. The CG was placed >60% below the native glenoid equator in 23 patients (85.2%) in group 2, compared with 14 patients (63.6%) in group 1 ( P = .004). In the axial plane, the position of the CG in group 2 patients was more accurate (85.2% and 88.9% flush) at the inferior and middle quartiles of the glenoid surface ( P = .012 and .009), respectively. Moreover, with the freehand technique (group 1), the graft was in a more lateral position in the inferior and middle quartiles ( P = .012 and .009, respectively). No differences were found between groups 1 and 2 regarding the mean α angle of the superior (9° ± 4.14° vs 11° ± 6.3°, P = .232) and inferior (9.5° ± 6° vs 10° ± 7.5°, P = .629) screws. However, the mean contact angle (angle between the posterior coracoid and the anterior glenoid surface) with the freehand technique (3.8° ± 6.8°) was better than that of the guide (8.55° ± 8°) ( P = .05). Compared with the classic freehand operative technique, the parallel drill guide can ensure

  8. Comparative Investigation on the Performance of Modified System Poles and Traditional System Poles Obtained from PDC Data for Diagnosing the Ageing Condition of Transformer Polymer Insulation Materials

    Directory of Open Access Journals (Sweden)

    Jiefeng Liu

    2018-02-01

    Full Text Available The life expectancy of a transformer is largely depended on the service life of transformer polymer insulation materials. Nowadays, several papers have reported that the traditional system poles obtained from polarization and depolarization current (PDC data can be used to assess the condition of transformer insulation systems. However, the traditional system poles technique only provides limited ageing information for transformer polymer insulation. In this paper, the modified system poles obtained from PDC data are proposed to assess the ageing condition of transformer polymer insulation. The aim of the work is to focus on reporting a comparative investigation on the performance of modified system poles and traditional system poles for assessing the ageing condition of a transformer polymer insulation system. In the present work, a series of experiments have been performed under controlled laboratory conditions. The PDC measurement data, degree of polymerization (DP and moisture content of the oil-immersed polymer pressboard specimens were carefully monitored. It is observed that, compared to the relationships between traditional system poles and DP values, there are better correlations between the modified system poles and DP values, because the modified system poles can obtain much more ageing information on transformer polymer insulation. Therefore, the modified system poles proposed in the paper are more suitable for the diagnosis of the ageing condition of transformer polymer insulation.

  9. Effects of slotting and unipolar flux on magnetic pull in a two-pole induction motor with an extra four-pole stator winding

    Energy Technology Data Exchange (ETDEWEB)

    Sinervo, A.

    2013-06-01

    This thesis is about the radial magnetic forces between the rotor and stator in twopole induction machines. The magnetic forces arise from rotor eccentricity. The asymmetric air-gap makes the flux density on one side of the rotor stronger than on the opposite side. This produces magnetic pull. The magnetic flux density distribution in the air-gap can be expressed with spatial harmonics, i.e. flux densities with different pole-pair numbers. In two-pole machines, the main part of the magnetic force is produced by the interaction of two- and fourpole flux unless the four-pole flux is damped by parallel paths in the stator winding or an extra four-pole stator winding. The rest of the force comes from the interaction of two-pole and unipolar flux and from the higher harmonics of the air-gap flux of which the slot harmonics are a major part. The force caused by the higher harmonics and the unipolar flux is studied in the case where a four-pole stator winding is used to reduce the four-pole flux. The higher harmonics are found to produce, in addition to the traditional unbalanced magnetic pull, a force similar to the effect of the unipolar flux and the two can be distinguished only by measuring the unipolar flux. In measurements at various operation points, the higher harmonics are found to produce much more force than the unipolar flux and two-pole flux but the unipolar flux is still significant. The four-pole winding also is used to actively control the four-pole flux and the magnetic forces. Designing the controller requires a low order model of the system. Such a model is derived and the effect of the slot harmonics and the unipolar flux are included in the model. Different measurements techniques and methods are presented to identify and validate the control model. The operation point dependence of the system dynamics is studied via measurements. All results are obtained from a 30 kW test motor. The rotor of the test machine has a long flexible shaft on external

  10. Poling of UV-written Waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Kristensen, Martin; Hübner, Jörg

    1999-01-01

    We report poling of UV-written silica waveguides. Thermal poling induces an electro-optic coefficient of 0.05 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. No measurable decay in the induced electro-optic effect was detected after nine months......We report poling of UV-written silica waveguides. Thermal poling induces an electro-optic coefficient of 0.05 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. No measurable decay in the induced electro-optic effect was detected after nine months...

  11. Heat generation during implant placement in low-density bone: effect of surgical technique, insertion torque and implant macro design.

    Science.gov (United States)

    Marković, Aleksa; Mišić, Tijana; Miličić, Biljana; Calvo-Guirado, Jose Luis; Aleksić, Zoran; Ðinić, Ana

    2013-07-01

    The study aimed to investigate the effect of surgical technique, implant macrodesign and insertion torque on bone temperature changes during implant placement. In the in vitro study, 144 self-tapping (blueSKY(®) 4 × 10 mm; Bredent) and 144 non-self-tapping (Standard implant(®) 4.1 × 10 mm; Straumann) were placed in osteotomies prepared in pig ribs by lateral bone condensing or bone drilling techniques. The maximum insertion torque values of 30, 35 and 40 Ncm were used. Real-time bone temperature measurement during implant placement was performed by three thermocouples positioned vertically, in tripod configuration around every osteotomy, at a distance of 5 mm from it and at depths of 1, 5 and 10 mm. Data were analysed using Kruskal-Wallis, Mann-Whitney U-tests and Regression analysis. Significant predictor of bone temperature at the osteotomy depth of 1 mm was insertion torque (P = 0.003) and at the depth of 10-mm implant macrodesign (P = 0.029), while no significant predictor at depth of 5 mm was identified (P > 0.05). Higher insertion torque values as well as non-self-tapping implant macrodesign were related to higher temperatures. Implant placement in sites prepared by bone drilling induced significantly higher temperature increase (P = 0.021) compared with bone condensing sites at the depth of 5 mm, while no significant difference was recorded at other depths. Compared with 30 Ncm, insertion torque values of 35 and 40 Ncm produced significantly higher temperature increase (P = 0.005; P = 0.003, respectively) at the depth of 1 mm. There was no significant difference in temperature change induced by 35 and 40 Ncm, neither by implant macrodesign at all investigated depths (P > 0.05). Placement of self-tapping implants with low insertion torque into sites prepared by lateral bone condensing technique might be advantageous in terms of thermal effect on bone. © 2012 John Wiley & Sons A/S.

  12. Mechanical Elongation of the Small Intestine: Evaluation of Techniques for Optimal Screw Placement in a Rodent Model

    Directory of Open Access Journals (Sweden)

    P. A. Hausbrandt

    2013-01-01

    Full Text Available Introduction. The aim of this study was to evaluate techniques and establish an optimal method for mechanical elongation of small intestine (MESI using screws in a rodent model in order to develop a potential therapy for short bowel syndrome (SBS. Material and Methods. Adult female Sprague Dawley rats (n=24 with body weight from 250 to 300 g (Σ=283 were evaluated using 5 different groups in which the basic denominator for the technique involved the fixation of a blind loop of the intestine on the abdominal wall with the placement of a screw in the lumen secured to the abdominal wall. Results. In all groups with accessible screws, the rodents removed the implants despite the use of washers or suits to prevent removal. Subcutaneous placement of the screw combined with antibiotic treatment and dietary modifications was finally successful. In two animals autologous transplantation of the lengthened intestinal segment was successful. Discussion. While the rodent model may provide useful basic information on mechanical intestinal lengthening, further investigations should be performed in larger animals to make use of the translational nature of MESI in human SBS treatment.

  13. The effects of poling on physiological, kinematic and kinetic responses in roller ski skating.

    Science.gov (United States)

    Grasaas, Erik; Hegge, Ann Magdalen; Ettema, Gertjan; Sandbakk, Øyvind

    2014-09-01

    We investigated the effects of poling on physiological, kinematic and kinetic responses in the G4 skating technique where the poling movement is synchronized with the leg push-off on one side (strong side) followed by a forward arm swing during the leg push-off on the other side (weak side). G4 skating with (G4-P) and without (G4-NP) poling was compared in 17 elite male cross-country skiers during 4-min submaximal tests on a 2% inclined roller ski treadmill at 10, 15 and 20 km h(-1). G4-P demonstrated less ventilatory stress and higher gross efficiency compared to G4-NP at all velocities, and the blood lactate concentration was lower at the high velocity (all P skating technique. Thus, poling provides possibilities to increase total propulsion, to reduce ski forces and to enhance skiing efficiency.

  14. Influence of PZT Coating Thickness and Electrical Pole Alignment on Microresonator Properties.

    Science.gov (United States)

    Janusas, Giedrius; Ponelyte, Sigita; Brunius, Alfredas; Guobiene, Asta; Vilkauskas, Andrius; Palevicius, Arvydas

    2016-11-10

    With increasing technical requirements in the design of microresonators, the development of new techniques for lightweight, simple, and inexpensive components becomes relevant. Lead zirconate titanate (PZT) is a powerful tool in the formation of these components, allowing a self-actuation or self-sensing capability. Different fabrication methods lead to the variation of the properties of the device itself. This research paper covers the fabrication of a novel PZT film and the investigations of its chemical, surface, and dynamic properties when film thickness is varied. A screen-printing technique was used for the formation of smooth films of 60 µm, 68 µm, and 25 µm thickness. A custom-made poling technique was applied to enhance the piezoelectric properties of the designed films. However, poling did not change any compositional or surface characteristics of the films; changes were only seen in the electrical ones. The results showed that a thinner poled PZT film having a chemical composition with the highest amount of copper and zirconium led to better electrical characteristics (generated voltage of 3.5 mV).

  15. Piezoelectric and dielectric characterization of corona and contact poled PZT-epoxy-MWCNT bulk composites

    Science.gov (United States)

    Banerjee, S.; Cook-Chennault, K. A.; Du, W.; Sundar, U.; Halim, H.; Tang, A.

    2016-11-01

    Three-phase lead zirconate titanate (PZT, PbZr0.52Ti0.48O3)-epoxy-multi-walled carbon nanotube (MWCNT) bulk composites were prepared, where the volume fraction of PZT was held constant at 30%, while the volume fraction of the MWCNTs was varied from 1.0%-10%. The samples were poled using either a parallel plate contact or contactless (corona) poling technique. The piezoelectric strain coefficient (d33), dielectric constant (ɛ), and dielectric loss tangent (tan δ) of the samples were measured at 110 Hz, and compared as a function of poling technique and volume fraction of MWCNTs. The highest values for dielectric constant and piezoelectric strain coefficients were 465.82 and 18.87 pC/N for MWCNT volume fractions of 10% and 6%, respectively. These values were obtained for samples that were poled using the corona contactless method. The impedance and dielectric spectra of the composites were recorded over a frequency range of 100 Hz-20 MHz. The impedance values observed for parallel-plate contact poled samples are higher than that of corona poled composites. The fractured surface morphology and distribution of the PZT particles and MWCNTs were observed with the aid of electron dispersion spectroscopy and a scanning electron microscope. The surface morphology of the MWCNTs was observed with the aid of a field emission transmission electron microscope.

  16. Pole-zero adjustment of spectroscopy amplifiers using multichannel analyzers

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, K; Grigorov, T [Inst. for Nuclear Research and Nuclear Energy, Sofia (Bulgaria)

    1996-12-31

    The technique to eliminate the undesirable undershoot in the output signal of a spectroscopy amplifier is considered. The functional scheme of the pole-zero monitoring circuit is presented as well as its operation principles are considered. 3 refs.

  17. Pole lengths influence O2-cost during double poling in highly trained cross-country skiers.

    Science.gov (United States)

    Carlsen, Camilla Høivik; Rud, Bjarne; Myklebust, Håvard; Losnegard, Thomas

    2018-02-01

    In elite cross-country skiing, double poling is used in different terrain. This study compared O 2 -cost and kinematics during double poling with four different pole lengths [self-selected (SS), SS - 5 cm, SS + 5 cm, SS + 10 cm] at Low versus Moderate incline. Thirteen highly trained male cross-country skiers (mean ± SD 23 ± 3 years; 182 ± 4 cm; 77 ± 6 kg) completed eight submaximal trials with roller skis on a treadmill at two conditions: "Low incline" (1.7°; 4.5 m s -1 ) and "Moderate incline" (4.5°; 2.5 m s -1 ) with each of the four pole lengths. O 2 -cost and 3D body kinematics were assessed in each trial. In Low incline, SS + 10 cm induced a lower O 2 -cost than all the other pole lengths [P size (ES) 0.5-0.8], whereas no differences were found between the remaining pole lengths (P > 0.05; ES 0.2-0.4). In Moderate incline, significant differences between all pole lengths were found for O 2 -cost, with SS - 5 cm > SS > SS + 5 cm > SS + 10 cm (P differences in O 2 -cost between SS and the other pole lengths were greater in Moderate incline than Low incline (SS - 5 cm; 1.5%, ES 0.8, SS + 5 cm; 1.3%, ES 1.0, and SS + 10 cm; 1.9%, ES 1.0, all P difference was found in cycle, poling or reposition times between pole lengths. However, at both conditions a smaller total vertical displacement of center of mass was observed with SS + 10 cm compared to the other pole lengths. Increasing pole length from SS - 5 cm to SS + 10 cm during double poling induced lower O 2 -cost and this advantage was greater in Moderate compared to Low incline.

  18. The History of Nontraditional or Ectopic Placement of Reservoirs in Prosthetic Urology.

    Science.gov (United States)

    Perito, Paul; Wilson, Steven

    2016-04-01

    Reservoir placement during implantation of prosthetic urology devices has been problematic throughout the history of the surgical treatment of erectile dysfunction and urinary incontinence. We thought it would be interesting to review the history of reservoir placement leading up to current surgical techniques. To provide an overview of the past and present techniques for reservoir placement and discuss the evolutionary process leading to safe and effective placement of prosthetic reservoirs. We reviewed data pertaining to inflatable penile prosthesis (IPP) reservoirs and pressure-regulating balloons (PRB) in a chronological fashion, spanning 25 years. Main outcomes included a historical review of techniques for IPP reservoir and PRB placement leading to the subsequent incremental improvements in safety and efficacy when performing penile implants and artificial urinary sphincters. Prosthetic urologic reservoirs have traditionally been placed in the retropubic space. Over the years, urologists have attempted use of alternative spaces including peritoneal, epigastric, "ectopic," posterior to transversalis, and high submuscular. Current advances in prosthetic urologic reservoir placement allow safe and effective abdominal wall placement of reservoirs. These novel approaches appear to be so effective that urologists may now be able to cease using the traditional retropubic space for reservoir placement, even in the case of virgin pelves. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  19. A novel technique to check the occlusion during the placement of stainless steel crowns under general anesthesia

    Directory of Open Access Journals (Sweden)

    Mohiddin Dimashkieh

    2015-01-01

    Full Text Available Stainless steel crowns are the restoration of choice for the treatment of badly decayed posterior teeth under general anesthesia. The evaluation of occlusion after the placement of these crowns, however, remains a difficult task. This paper outlines a technique to evaluate the occlusion of stainless steel crowns placed under general anesthesia using a specially designed tray and a fast setting polyvinyl siloxane bite registration material (Regisil® PB™, Dentsply, Surrey UK.

  20. The physiological and biomechanical contributions of poling to roller ski skating.

    Science.gov (United States)

    Sandbakk, Øyvind; Ettema, Gertjan; Holmberg, Hans-Christer

    2013-08-01

    Poling is considered to make a significant contribution to cross-country skiing with the skating technique. To better understand this contribution, the current investigation compared roller ski skating on a treadmill with the so-called G3 skating technique with (G3-P) and without poling (G3-NP). Seven male elite skiers performed 5-min submaximal tests at 8, 12, and 15 km h(-1), as well as an incremental test to exhaustion with both techniques on a 5 % incline. Ventilatory variables were assessed by open-circuit indirect calorimetry and three-dimensional kinematics analyzed using the Qualisys Pro Reflex system. G3-P was associated with approximately 15 % higher peak velocity and 10 % higher peak oxygen uptake than G3-NP in the incremental test (both P skating, specifically by enhancing peak oxygen uptake, skiing efficiency and associated biomechanical variables.

  1. 2D Stabilised analytic signal method in DC pole-pole potential data ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    synthetic error prone secondary pole-pole potential data. 1. Introduction. Analytical signal .... The meaning of the rest of the parameters is self- evident. The three ..... interpretation using 3-D analytic signal; Geophysics 57. 116–125. Starostenko ...

  2. Permanent magnet machine and method with reluctance poles and non-identical PM poles for high density operation

    Science.gov (United States)

    Hsu, John S.

    2010-05-18

    A method and apparatus in which a stator (11) and a rotor (12) define a primary air gap (20) for receiving AC flux and at least one source (23, 40), and preferably two sources (23, 24, 40) of DC excitation are positioned for inducing DC flux at opposite ends of the rotor (12). Portions of PM material (17, 17a) are provided as boundaries separating PM rotor pole portions from each other and from reluctance poles. The PM poles (18) and the reluctance poles (19) can be formed with poles of one polarity having enlarged flux paths in relation to flux paths for pole portions of an opposite polarity, the enlarged flux paths communicating with a core of the rotor (12) so as to increase reluctance torque produced by the electric machine. Reluctance torque is increased by providing asymmetrical pole faces. The DC excitation can also use asymmetric poles and asymmetric excitation sources. Several embodiments are disclosed with additional variations.

  3. The Free-Hand Technique for S2-Alar-Iliac Screw Placement: A Safe and Effective Method for Sacropelvic Fixation in Adult Spinal Deformity.

    Science.gov (United States)

    Shillingford, Jamal N; Laratta, Joseph L; Tan, Lee A; Sarpong, Nana O; Lin, James D; Fischer, Charla R; Lehman, Ronald A; Kim, Yongjung J; Lenke, Lawrence G

    2018-02-21

    Spinopelvic fixation is an integral part of achieving solid fusion across the lumbosacral junction, especially in deformity procedures requiring substantial correction or long-segment constructs. Traditional S2-alar-iliac (S2AI) screw-placement techniques utilize fluoroscopy, increasing operative time and radiation exposure to the patient and surgeon. We describe a novel free-hand technique for S2AI screw placement in patients with adult spinal deformity. We reviewed the records of 45 consecutive patients who underwent spinopelvic fixation performed with use of S2AI screws by the senior surgeon and various fellows or residents over a 12-month period (2015 to 2016). In each case, the S2AI screws were placed utilizing a free-hand technique without fluoroscopic or image guidance. Screw position and accuracy were assessed by intraoperative O-arm imaging and analyzed using 3-dimensional interactive manipulation of computed tomography images. A total of 100 screws were placed, 51 by the senior surgeon and 49 by trainees. The mean patient age was 57.4 ± 12.7 years at the time of surgery; 37 (82.2%) of the patients were female. Preoperative diagnoses included adult idiopathic scoliosis (n = 19), adult degenerative scoliosis (n = 15), flatback syndrome (n = 2), fixed sagittal imbalance (n = 6), and distal junctional kyphosis (n = 3). Five (5%) of the screws were placed with moderate to severe cortical breaches, all of which perforated the pelvis posteriorly, with no clinically notable neurovascular or visceral complications. The breach rate did not differ significantly between the senior surgeon and trainees. The free-hand technique for S2AI screw placement, when performed in a standardized manner, was demonstrated to be safe and reliable in constructs requiring spinopelvic fixation. The accuracy of screw placement relies on visible and palpable anatomic landmarks that obviate the need for intraoperative fluoroscopy or image guidance, potentially reducing operative time

  4. RHEED transmission mode and pole figures thin film and nanostructure texture analysis

    CERN Document Server

    Wang, Gwo-Ching

    2014-01-01

    This unique book covers the fundamental principle of electron diffraction, basic instrumentation of RHEED, definitions of textures in thin films and nanostructures, mechanisms and control of texture formation, and examples of RHEED transmission mode measurements of texture and texture evolution of thin films and nanostructures. Also presented is a new application of RHEED in the transmission mode called RHEED pole figure technique that can be used to monitor the texture evolution in thin film growth and nanostructures and is not limited to single crystal epitaxial film growth. Details of the construction of RHEED pole figures and the interpretation of observed pole figures are presented.  Materials covered include metals, semiconductors, and thin insulators. This book also: Presents a new application of RHEED in the transmission mode Introduces a variety of textures from metals, semiconductors, compound semiconductors, and their characteristics in RHEED pole figures Provides examples of RHEED measurements o...

  5. Tree-loop duality relation beyond single poles

    Energy Technology Data Exchange (ETDEWEB)

    Bierenbaum, Isabella [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Buchta, Sebastian; Draggiotis, Petros; Malamos, Ioannis; Rodrigo, German [Valencia Univ. Paterna (Spain). Inst. de Fisica Corpuscular

    2012-11-15

    We develop the Tree-Loop Duality Relation for two- and three-loop integrals with multiple identical propagators (multiple poles). This is the extension of the Duality Relation for single poles and multi-loop integrals derived in previous publications. We prove a generalization of the formula for single poles to multiple poles and we develop a strategy for dealing with higher-order pole integrals by reducing them to single pole integrals using Integration By Parts.

  6. K.s. Micro-implant placement guide.

    Science.gov (United States)

    Sharma, K; Sangwan, A

    2014-09-01

    A one of the greatest concerns with orthodontic mini-implants is risk of injury to dental roots during placement is, especially when they are inserted between teeth. Many techniques have been used to facilitate safe placement of interradicular miniscrews. Brass Wires or metallic markers are easy to place in the interproximal spaces, but because their relative positions may be inconsistent in different radio -graphic views, they are not always accurate. K.S. micro implant placement guide suggested in this article is simple design and easy in fabrication, required minimal equipment for fabrication and does not disturb the existing appliance system, clearly located in the radiograph and the mini-screw can be easily inserted through the guide reducing the chance of implant misplacement.

  7. Neutron pole figures compared with magnetic preferred orientations of different rock types

    International Nuclear Information System (INIS)

    Hansen, Anke; Chadima, Martin; Cifelli, Francesca; Brokmeier, H.-G.Heinz-Guenter; Siemes, Heinrich

    2004-01-01

    Neutron diffraction is an excellent tool for pole figure measurement of rock samples. Due to high penetration depth of neutrons for most materials neutron diffraction represents an efficient tool to measure complete pole figures with reliable grain statistics even in coarse grained or inequi-granular materials. In the field of structural geology, the measurement of anisotropy of magnetic susceptibility is a standard technique to reveal the tectonic history of deformed rocks. The application of both techniques on still ongoing studies of Precambrian, Carboniferous and Quaternary rocks which are characterised by fundamental different tectonic evolutions and mineralogical compositions shows the wide field of relevance and importance of these methods in understanding tectonic processes in detail

  8. PRODUCT PLACEMENT IN BRAND PROMOTION

    Directory of Open Access Journals (Sweden)

    Alicja Mikołajczyk

    2015-06-01

    Full Text Available Product placement can have a significant impact on brand awareness and customer purchasing decisions. The article discusses techniques applied in the mass media against the EU legal background and the opportunities it offers in reaching the target audience.

  9. Integrated 3D printing and corona poling process of PVDF piezoelectric films for pressure sensor application

    Science.gov (United States)

    Kim, Hoejin; Torres, Fernando; Wu, Yanyu; Villagran, Dino; Lin, Yirong; Tseng, Tzu-Liang(Bill

    2017-08-01

    This paper presents a novel process to fabricate piezoelectric films from polyvinylidene fluoride (PVDF) polymer using integrated fused deposition modeling (FDM) 3D printing and corona poling technique. Corona poling is one of many effective poling processes that has received attention to activate PVDF as a piezoelectric responsive material. The corona poling process occurs when a PVDF polymer is exposed to a high electric field created and controlled through an electrically charged needle and a grid electrode under heating environment. FDM 3D printing has seen extensive progress in fabricating thermoplastic materials and structures, including PVDF. However, post processing techniques such as poling is needed to align the dipoles in order to gain piezoelectric properties. To further simplify the piezoelectric sensors and structures fabrication process, this paper proposes an integrated 3D printing process with corona poling to fabricate piezoelectric PVDF sensors without post poling process. This proposed process, named ‘Integrated 3D Printing and Corona poling process’ (IPC), uses the 3D printer’s nozzle and heating bed as anode and cathode, respectively, to create poling electric fields in a controlled heating environment. The nozzle travels along the programmed path with fixed distance between nozzle tip and sample’s top surface. Simultaneously, the electric field between the nozzle and bottom heating pad promotes the alignment of dipole moment of PVDF molecular chains. The crystalline phase transformation and output current generated by printed samples under different electric fields in this process were characterized by a Fourier transform infrared spectroscopy and through fatigue load frame. It is demonstrated that piezoelectric PVDF films with enhanced β-phase percentage can be fabricated using the IPC process. In addition, mechanical properties of printed PVDF was investigated by tensile testing. It is expected to expand the use of additive

  10. Novel Technique for Hepatic Fiducial Marker Placement for Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Jarraya, Hajer; Chalayer, Chloé; Tresch, Emmanuelle; Bonodeau, Francois; Lacornerie, Thomas; Mirabel, Xavier; Boulanger, Thomas; Taieb, Sophie; Kramar, Andrew; Lartigau, Eric; Ceugnart, Luc

    2014-01-01

    Purpose: To report experience with fiducial marker insertion and describe an advantageous, novel technique for fiducial placement in the liver for stereotactic body radiation therapy with respiratory tracking. Methods and Materials: We implanted 1444 fiducials (single: 834; linked: 610) in 328 patients with 424 hepatic lesions. Two methods of implantation were compared: the standard method (631 single fiducials) performed on 153 patients from May 2007 to May 2010, and the cube method (813 fiducials: 610 linked/203 single) applied to 175 patients from April 2010 to March 2013. The standard method involved implanting a single marker at a time. The novel technique entailed implanting 2 pairs of linked markers when possible in a way to occupy the perpendicular edges of a cube containing the tumor inside. Results: Mean duration of the cube method was shorter than the standard method (46 vs 61 minutes; P<.0001). Median numbers of skin and subcapsular entries were significantly smaller with the cube method (2 vs 4, P<.0001, and 2 vs 4, P<.0001, respectively). The rate of overall complications (total, major, and minor) was significantly lower in the cube method group compared with the standard method group (5.7% vs 13.7%; P=.013). Major complications occurred while using single markers only. The success rate was 98.9% for the cube method and 99.3% for the standard method. Conclusions: We propose a new technique of hepatic fiducial implantation that makes use of linked fiducials and involves fewer skin entries and shorter time of implantation. The technique is less complication-prone and is migration-resistant

  11. Minimal guided bone regeneration procedure for immediate implant placement in the esthetic zone

    Directory of Open Access Journals (Sweden)

    Nettemu Sunil Kumar

    2013-01-01

    Full Text Available The anterior maxilla presents a challenging milieu interior for ideal placement of implants because of the compromised bone quality. With the advent of intraoral bone harvesting and augmentation techniques, immediate implant placement into fresh extraction sockets have become more predictable. Immediate implant placement has numerous advantages compared to the delayed procedure including superior esthetic and functional outcomes, maintenance of soft and hard tissue integrity and increased patient compliance. This case report exhibits immediate implant placement in the maxillary esthetic zone by combining a minimal invasive autogenous block bone graft harvest technique for ensuring successful osseointegration of the implant at the extraction site.

  12. Simplified Analytic Approach of Pole-to-Pole Faults in MMC-HVDC for AC System Backup Protection Setting Calculation

    Directory of Open Access Journals (Sweden)

    Tongkun Lan

    2018-01-01

    Full Text Available AC (alternating current system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC into power grids, it has been a big challenge for the AC system backup protection setting calculation, as the MMC-HVDC lacks the fault self-clearance capability under pole-to-pole faults. This paper focused on the pole-to-pole faults analysis for the AC system backup protection setting calculation. The principles of pole-to-pole faults analysis were discussed first according to the standard of the AC system protection setting calculation. Then, the influence of fault resistance on the fault process was investigated. A simplified analytic approach of pole-to-pole faults in MMC-HVDC for the AC system backup protection setting calculation was proposed. In the proposed approach, the derived expressions of fundamental frequency current are applicable under arbitrary fault resistance. The accuracy of the proposed approach was demonstrated by PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC simulations.

  13. Totally implantable vascular access device (TIVAD) placement: a modified technique that takes post-procedure aesthetic aspects into account.

    Science.gov (United States)

    Liberale, Gabriel

    2017-04-01

    Major progress has been made in breast cancer reconstruction surgery. The standard technique for totally implanted vascular access device (TIVAD) implantation generally requires an incision for port insertion on the anterior part of the thorax that leaves a scar in the middle of the neckline in patients who have undergone mastectomy with complex breast reconstruction. The aim of this technical note is to report our revised surgical technique for TIVAD placement. In patients with breast cancer, we take a lateralized approach, performing an oblique incision on the lowest part of the deltopectoral groove. This allows us to introduce the port and to place it on the anterolateral part of the thorax, thus avoiding an unaesthetic scar on the anterior part of the thorax. Our modified technique for TIVAD implantation is described.

  14. Determination of pole orientations and shapes of asteroids

    International Nuclear Information System (INIS)

    Magnusson, P.; Barucci, M.A.; Drummond, J.D.; Lumme, K.; Surdej, J.

    1989-01-01

    The principles of asteroid lightcurve inversion and the information available from photometry are reviewed. General tools as well as specific techniques for shape and pole determinations are summarized and their advantages and shortcomings are discussed. The authors present the results obtained so far in this very active field and discuss their significance in the general context of asteroid research and planetary formation

  15. A Fast Placement Technique for Covered Tracheobronchial Stents in Patients with Complicated Esophagorespiratory Fistulas

    International Nuclear Information System (INIS)

    Kishi, Kazushi; Nakao, Taisei; Goto, Hironobu; Kimura, Masashi; Sonomura, Tetsuo; Yamanaka, Noboru; Nanjo, Kishio; Sato, Morio

    2005-01-01

    Purpose. To test an endotracheal placement procedure for malignant esophagorespiratory fistula when endoesophageal placement is inapplicable. Methods. We report on patients with malignant esophagorespiratory fistula to which endoesophageal approaches were complicated with a complete obstruction of the hypopharynx, a collapsible tracheobronchus, or a previously placed endoesophageal stents. Gore-Tex membrane-covered Z-stents were deployed in the trachea using a coaxial introducer system in three patients. A Dumon tube was deployed in the bronchus over the bronchofiberscope in one patient. Results. All fistula were completely sealed by the endotracheal or endobronchial stenting. Symptomatic and clinical improvements were immediate obtained. Conclusion. Endotracheal or endobronchial covered stent placement is thought to be an effective alternative method for sealing esophagorespiratory fistula

  16. Inferior Alveolar Nerve Lateralization and Transposition for Dental Implant Placement. Part I: a Systematic Review of Surgical Techniques

    Directory of Open Access Journals (Sweden)

    Boris Abayev

    2015-03-01

    Full Text Available Objectives: The purpose of this first part of a two-part series was to review the literature concerning the indications, contraindications, advantages, disadvantages and surgical techniques of the lateralization and transposition of the inferior alveolar nerve, followed by the placement of an implant in an edentulous atrophic posterior mandible. Material and Methods: A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed and PMC database, academic sites and books. The articles were searched from January 1997 to July 2014 and comprised English-language articles that included adult patients between 18 and 80 years old with minimal residual bone above the mandibular canal who had undergone inferior alveolar nerve (IAN repositioning with a minimum 6 months of follow-up. Results: A total of 16 studies were included in this review. Nine were related to IAN transposition, 4 to IAN lateralization and 3 to both transposition and lateralization. Implant treatment results and complications were presented. Conclusions: Inferior alveolar nerve lateralization and transposition in combination with the installation of dental implants is sometimes the only possible procedure to help patients to obtain a fixed prosthesis, in edentulous atrophic posterior mandibles. With careful pre-operative surgical and prosthetic planning, imaging, and extremely precise surgical technique, this procedure can be successfully used for implant placement in edentulous posterior mandibular segments.

  17. Talar anchor placement for modified Brostrom lateral ankle stabilization procedure.

    Science.gov (United States)

    Angirasa, Arush K; Barrett, Michael J

    2008-01-01

    The modified Brostrom procedure has been a proven procedure with excellent utility in the treatment of lateral ankle instability within limitation. Multiple variations of the original technique have been described in the literature to date. Included in these variations are differences in anchor placement, suture technique, or both. In this research study, we propose placing a bone screw anchor into the lateral shoulder of the talus rather than the typical placement at the lateral malleolus for anatomic reconstruction of the lateral ankle ligaments.

  18. The potential of wood-based composite poles

    Science.gov (United States)

    Todd F. Shupe; Cheng Piao; Chung Y. Hse

    2009-01-01

    Wood-based composite utility poles are receiving increasing attention in the North American pole market. This interest is being driven by many increasing factors such as increasing: (1) disposal costs of solid wood poles, (2) liability and environmental concerns with traditional means of disposal of solid wood poles, (3) cost and concerns of long-term...

  19. Use of the Toric Surgical Marker to Aid in Intraoperative Plaque Placement for the USC Eye Physics Plaques to Treat Uveal Melanoma: A New Surgical Technique.

    Science.gov (United States)

    Berry, Jesse L; Kim, Jonathan W; Jennelle, Richard; Astrahan, Melvin

    2015-09-01

    To describe a new surgical technique for intraoperative placement of Eye Physics (EP) plaques for uveal melanoma using a toric marker. A toric marker is designed for cataract surgery to align the axis of astigmatism; its use was modified in this protocol to mark the axis of suture coordinates as calculated by Plaque Simulator (PS) software. The toric marker can be used to localize suture coordinates, in degrees, during intraoperative plaque placement. Linear marking using the toric marker decreases potential inaccuracies associated with the surgeon estimating 'clock-hours' by dot placement. Use of the toric marker aided surgical placement of EP plaques. The EP planning protocol is now designed to display the suture coordinates either by clock-hours or degrees, per surgeon preference. Future research is necessary to determine whether routine use of the toric marker improves operative efficiency. [Ophthalmic Surg Lasers Imaging Retina. 2015;46:866-870.]. Copyright 2015, SLACK Incorporated.

  20. Kick, Glide, Pole! Cross-Country Skiing Fun (Part II)

    Science.gov (United States)

    Duoos, Bridget A.

    2012-01-01

    Part I of Kick, Glide, Pole! Cross-Country Skiing Fun, which was published in last issue, discussed how to select cross-country ski equipment, dress for the activity and the biomechanics of the diagonal stride. Part II focuses on teaching the diagonal stride technique and begins with a progression of indoor activities. Incorporating this fun,…

  1. Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique.

    Science.gov (United States)

    Jin, Mengran; Liu, Zhen; Liu, Xingyong; Yan, Huang; Han, Xiao; Qiu, Yong; Zhu, Zezhang

    2016-06-01

    To assess the accuracy of O-arm-navigation-based pedicle screw insertion in dystrophic scoliosis secondary to NF-1 and compare it with free-hand pedicle screw insertion technique. 32 patients with dystrophic NF-1-associated scoliosis were divided into two groups. A total of 92 pedicle screws were implanted in apical region (two vertebrae above and below the apex each) in 13 patients using O-arm-based navigation (O-arm group), and 121 screws were implanted in 19 patients using free-hand technique (free-hand group). The postoperative CT images were reviewed and analyzed for pedicle violation. The screw penetration was divided into four grades: grade 0 (ideal placement), grade 1 (penetration 4 mm). The accuracy rate of pedicle screw placement (grade 0, 1) was significantly higher in the O-arm group (79 %, 73/92) compared to 67 % (81/121) of the free-hand group (P = 0.045). Meanwhile, a significantly lower prevalence of grade 2-3 perforation was observed in the O-arm group (21 vs. 33 %, P arm navigation compared to free-hand technique (2 vs. 15 %, P arm navigation (58 vs. 42 %, P arm-based pedicle screw placement in dystrophic NF-1-associated scoliosis. O-arm navigation system does facilitate pedicle screw insertion in dystrophic NF-1-associated scoliosis, demonstrating superiorities in the safety and accuracy of pedicle screw placement in comparison with free-hand technique.

  2. Patellar Shape-Memory Fixator for the Treatment of Comminuted Fractures of the Inferior Pole of the Patella

    Science.gov (United States)

    Liu, Xin-Wei; Shang, Hui-Juan; Xu, Shuo-Gui; Wang, Zhi-Wei; Zhang, Chun-Cai; Fu, Qing-Ge

    2011-07-01

    Comminuted and displaced fractures of the inferior pole of the patella are not easy to reduce and it is difficult to fix the fragments soundly enough to allow early movement of the knee. The purpose of this study is to evaluate the clinical effectiveness of the internal fixation technique with Patellar Shape-Memory Fixator (PSMF) in acute comminuted fractures of the inferior pole of the patella. We retrospectively studied 25 patients with comminuted fractures of the inferior pole of the patella who were treated with PSMF and followed up for a mean period of 26 months (14 to 60). All the fractures healed at a mean of 6 weeks (5 to 7). The mean grading at the final follow-up was 29.5 points (27 to 30) using the Bostman score, with no observable restriction of movement. No breakage of the PSMF or infection occurred. No delayed union, nonunion, and infection were seen. This technique preserved the length of the patella, reduced the comminuted fragments of the inferior pole and avoided long-term immobilization of the knee.

  3. Comparison of metaheuristic techniques to determine optimal placement of biomass power plants

    International Nuclear Information System (INIS)

    Reche-Lopez, P.; Ruiz-Reyes, N.; Garcia Galan, S.; Jurado, F.

    2009-01-01

    This paper deals with the application and comparison of several metaheuristic techniques to optimize the placement and supply area of biomass-fueled power plants. Both, trajectory and population-based methods are applied for our goal. In particular, two well-known trajectory method, such as Simulated Annealing (SA) and Tabu Search (TS), and two commonly used population-based methods, such as Genetic Algorithms (GA) and Particle Swarm Optimization (PSO) are hereby considered. In addition, a new binary PSO algorithm has been proposed, which incorporates an inertia weight factor, like the classical continuous approach. The fitness function for the metaheuristics is the profitability index, defined as the ratio between the net present value and the initial investment. In this work, forest residues are considered as biomass source, and the problem constraints are: the generation system must be located inside the supply area, and its maximum electric power is 5 MW. The comparative results obtained by all considered metaheuristics are discussed. Random walk has also been assessed for the problem we deal with.

  4. Comparison of metaheuristic techniques to determine optimal placement of biomass power plants

    Energy Technology Data Exchange (ETDEWEB)

    Reche-Lopez, P.; Ruiz-Reyes, N.; Garcia Galan, S. [Telecommunication Engineering Department, University of Jaen Polytechnic School, C/ Alfonso X el Sabio 28, 23700 Linares, Jaen (Spain); Jurado, F. [Electrical Engineering Department, University of Jaen Polytechnic School, C/ Alfonso X el Sabio 28, 23700 Linares, Jaen (Spain)

    2009-08-15

    This paper deals with the application and comparison of several metaheuristic techniques to optimize the placement and supply area of biomass-fueled power plants. Both, trajectory and population-based methods are applied for our goal. In particular, two well-known trajectory method, such as Simulated Annealing (SA) and Tabu Search (TS), and two commonly used population-based methods, such as Genetic Algorithms (GA) and Particle Swarm Optimization (PSO) are hereby considered. In addition, a new binary PSO algorithm has been proposed, which incorporates an inertia weight factor, like the classical continuous approach. The fitness function for the metaheuristics is the profitability index, defined as the ratio between the net present value and the initial investment. In this work, forest residues are considered as biomass source, and the problem constraints are: the generation system must be located inside the supply area, and its maximum electric power is 5 MW. The comparative results obtained by all considered metaheuristics are discussed. Random walk has also been assessed for the problem we deal with. (author)

  5. A comparative study of two techniques (electrocardiogram- and landmark-guided for correct depth of the central venous catheter placement in paediatric patients undergoing elective cardiovascular surgery

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar Barnwal

    2016-01-01

    Full Text Available Background and Aims: The complications of central venous catheterisation can be minimized by ensuring catheter tip placement just above the superior vena cava-right atrium junction. We aimed to compare two methods, using an electrocardiogram (ECG or landmark as guides, for assessing correct depth of central venous catheter (CVC placement. Methods: In a prospective randomised study of sixty patients of <12 years of age, thirty patients each were allotted randomly to two groups (ECG and landmark. After induction, central venous catheterisation was performed by either of the two techniques and position of CVC tip was compared in post-operative chest X-ray with respect to carina. Unpaired t-test was used for quantitative data and Chi-square test was used for qualitative data. Results: In ECG group, positions of CVC tip were above carina in 12, at carina in 9 and below carina in 9 patients. In landmark group, the positions of CVC tips were above carina in 10, at carina in 4 and below carina in 16 patients. Mean distance of CVC tip in ECG group was 0.34 ± 0.23 cm and 0.66 ± 0.35 cm in landmark group (P = 0.0001. Complications occurred in one patient in ECG group and in nine patients in landmark group (P = 0.0056. Conclusion: Overall, landmark-guided technique was comparable with ECG technique. ECG-guided technique was more precise for CVC tip placement closer to carina. The incidence of complications was more in the landmark group.

  6. Hollow mandrin facilitates external ventricular drainage placement.

    Science.gov (United States)

    Heese, O; Regelsberger, J; Kehler, U; Westphal, M

    2005-07-01

    Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening

  7. An efficient macro-cell placement algorithm

    NARCIS (Netherlands)

    Aarts, E.H.L.; Bont, de F.M.J.; Korst, J.H.M.; Rongen, J.M.J.

    1991-01-01

    A new approximation algorithm is presented for the efficient handling of large macro-cell placement problems. The algorithm combines simulated annealing with new features based on a hierarchical approach and a divide-and-conquer technique. Numerical results show that these features can lead to a

  8. Eight piece quadrupole magnet, method for aligning quadrupole magent pole tips

    Science.gov (United States)

    Jaski, Mark S.; Liu, Jie; Donnelly, Aric T.; Downey, Joshua S.; Nudell, Jeremy J.; Jain, Animesh

    2018-01-30

    The invention provides an alternative to the standard 2-piece or 4-piece quadrupole. For example, an 8-piece and a 10-piece quadrupole are provided whereby the tips of each pole may be adjustable. Also provided is a method for producing a quadrupole using standard machining techniques but which results in a final tolerance accuracy of the resulting construct which is better than that obtained using standard machining techniques.

  9. Keyword: Placement

    Science.gov (United States)

    Cassuto, Leonard

    2012-01-01

    The practical goal of graduate education is placement of graduates. But what does "placement" mean? Academics use the word without thinking much about it. "Placement" is a great keyword for the graduate-school enterprise. For one thing, its meaning certainly gives a purpose to graduate education. Furthermore, the word is a portal into the way of…

  10. Single-staged vs. two-staged implant placement using bone ring technique in vertically deficient alveolar ridges - Part 1: histomorphometric and micro-CT analysis.

    Science.gov (United States)

    Nakahara, Ken; Haga-Tsujimura, Maiko; Sawada, Kosaku; Kobayashi, Eizaburo; Mottini, Matthias; Schaller, Benoit; Saulacic, Nikola

    2016-11-01

    Simultaneous implant placement with bone grafting shortens the overall treatment period, but might lead to the peri-implant bone loss or even implant failure. The aim of this study was to compare the single-staged to two-staged implant placement using the bone ring technique. Four standardized alveolar bone defects were made in the mandibles of nine dogs. Dental implants (Straumann BL ® , Basel, Switzerland) were inserted simultaneously with bone ring technique in test group and after 6 months of healing period in control group. Animals of both groups were euthanized at 3 and 6 months of osseointegration period. The harvested samples were analyzed by means of histology and micro-CT. The amount of residual bone decreased while the amount of new bone increased up to 9 months of healing period. All morphometric parameters remained stable between 3 and 6 months of osseointegration period within groups. Per a given time point, median area of residual bone graft was higher in test group and area of new bone in control group. The volume of bone ring was greater in test than in control group, reaching the significance at 6 months of osseointegration period (P = 0.002). In the present type of bone defect, single-staged implant placement may be potentially useful to shorten an overall treatment period. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Stresses generated by two zygomatic implant placement techniques associated with conventional inclined anterior implants

    Directory of Open Access Journals (Sweden)

    Paulo H.T. Almeida

    2018-06-01

    Full Text Available Purpose: To make a comparative evaluation, by means of the finite element method, of the stress generated on supporting tissues and prosthetic system components, using zygomatic implants with the exteriorized and extramaxillary techniques, and different placement positions, associated either with inclined anterior implants, or those without inclination. Materials and methods: Eight (8 tridimensional models were created to represent the clinical situations being researched, using the dataset of scanned images of an edentulous model. The implants and prosthetic components were photographed on millimeter paper and inserted into Rhinoceros 3D modeling computer software. From the measurements made on the image, the virtual models were made. The application force was distributed on the occlusal surface of the working side of the left maxillary first molar, first and second premolars, and incisal regions of the central incisor, simulating the occlusal load during mastication, in a total of 150 N. Results: The extramaxillary technique presented considerable variation in increased tension on the prosthesis screws and bone tissue. In the exteriorized technique, the highest tension values occurred in the region of the ridge, and the lowest, on the zygomatic process; the absence of cantilever reduced the stress on bone tissue in almost all regions. Conclusion: The exteriorized technique was shown to be more favorable to the distribution of stresses on the micro-unit screws and bone tissue, with the model with zygomatic implant placed in the region of the first molar and inclined anterior implant presenting the best results. Keywords: Zygomatic implants, Atrophic maxilla, Finite element analysis, Cantilever, Inclined implant

  12. Evaluation of the pole figure

    International Nuclear Information System (INIS)

    Cabrera B, E.; Macias B, L.R.

    1984-01-01

    In the present work it's shown the possibility of obtaining a pole-figure from the data generated in a conventional X-ray equipment, with a commercial goniometer and no electronic device to process the data. The way to plot the pole-figure on-line is by means of measuring the diffractogram and plot manually the stereographic projections. The atainable precision is very low in such a cumbersome process. In this paper we substitute such method by storing the data in a punched tape from a conventional teletype. The data is processed in a computer and the pole-figure is recorded by a plotter attached to the computer. (author)

  13. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  14. Method and apparatus for assembling a permanent magnet pole assembly

    Science.gov (United States)

    Carl, Jr., Ralph James; Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Dawson, Richard Nils [Voorheesville, NY; Qu, Ronghai [Clifton Park, NY; Avanesov, Mikhail Avramovich [Moscow, RU

    2009-08-11

    A pole assembly for a rotor, the pole assembly includes a permanent magnet pole including at least one permanent magnet block, a plurality of laminations including a pole cap mechanically coupled to the pole, and a plurality of laminations including a base plate mechanically coupled to the pole.

  15. Mapping the temporal pole with a specialized electrode array: technique and preliminary results

    International Nuclear Information System (INIS)

    Abel, Taylor J; Rhone, Ariane E; Nourski, Kirill V; Oya, Hiroyuki; Kawasaki, Hiroto; Howard, Matthew A III; Granner, Mark A; Tranel, Daniel T; Griffiths, Timothy D

    2014-01-01

    Temporopolar cortex plays a crucial role in the pathogenesis of temporal lobe epilepsy and subserves important cognitive functions. Because of its shape and position in the middle cranial fossa, complete electrode coverage of the temporal pole (TP) is difficult to achieve using existing devices. We designed a novel TP electrode array that conforms to the surface of temporopolar cortex and achieves dense electrode coverage of this important brain region. A multi-pronged electrode array was designed that can be placed over the surface of the TP using a straightforward insertion technique. Twelve patients with medically intractable epilepsy were implanted with the TP electrode array for purposes of seizure localization. Select patients underwent cognitive mapping by electrocorticographic (ECoG) recording from the TP during a naming task. Use of the array resulted in excellent TP electrode coverage in all patients. High quality ECoG data were consistently obtained for purposes of delineating seizure activity and functional mapping. During a naming task, significant increases in ECoG power were observed within localized subregions of the TP. One patient developed a transient neurological deficit thought to be related to the mass effect of multiple intracranial recording arrays, including the TP array. This deficit resolved following removal of all electrodes. The TP electrode array overcomes limitations of existing devices and enables clinicians and researchers to obtain optimal multi-site recordings from this important brain region. (paper)

  16. Crystalline texture study of Zr-2.5%Nb pressure pipes by DRX pole figures

    International Nuclear Information System (INIS)

    Buioli, C P; Banchik, A D; Vizcaino, P; Samper, R; Testone, S

    2012-01-01

    This work presents the study of crystalline texture of Zr-2.5%Nb pressure tubes (A, B and C); structural components of CANDU nuclear power reactors [1]. The study of texture was made using the RX diffraction technique, making measurements of direct pole figures [2], in a Phillips diffractometer with pole goniometer (IFIR-CONICET). The texture was determined calculating the coefficients of JJ Kearns [3]. The samples used correspond to transversal sections of the tubes, front and back, and were characterized making de measurements of five pole figures with Miller index (001), (100), (101), (102) and (110), in order to represent in a complete way the texture in the material. The calculated Kearns coefficients were compared with the specifications given by the designer of pressure tubes AECL [4] (author)

  17. Utility poles not affected by CCA decision

    Energy Technology Data Exchange (ETDEWEB)

    De Venzio, H. [Arch Wood Protection Canada, Mississauga, ON (Canada)

    2002-08-01

    A voluntary decision by industry to move non-industrial use of treated lumber products away from pressure-treated wood containing chromated copper arsenate (CCA) preservative was announced by the Environmental Protection Agency on February 12, 2002. Although new alternative wood preservatives would be used, this decision does not affect utility poles, which will continue to be sold and installed. The author provides a brief historical outline concerning the creation of CCA in 1933 and its subsequent uses. CCA has many advantages, including clean surface of the poles, ground line treatment that is not required thus eliminating the requirement to rotate the poles during extended storage periods. Conductivity is low, as is corrosivity without affecting the bending characteristics of the wood. The injection of a refined hydrocarbon oil emulsion in the outer layer of the pole after the treatment with CCA is offered by some pole producers to facilitate gaff penetration. Sawing, drilling and nailing are also made easier. Water repellents can be added to the treating solution to improve climbability, slowing down the absorption and release of moisture. Warranties, extending for 50-year periods, are offered by some companies against wood-destroying organisms. The North American Wood Pole Coalition (NAWPC) was formed in 1998 to promote the use of wood poles, and publishes brochures and technical bulletins to that effect.

  18. Optimal PMU Placement By Improved Particle Swarm Optimization

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Liu, Leo; Chen, Zhe

    2013-01-01

    This paper presents an improved method of binary particle swarm optimization (IBPSO) technique for optimal phasor measurement unit (PMU) placement in a power network for complete system observability. Various effective improvements have been proposed to enhance the efficiency and convergence rate...... of conventional particle swarm optimization method. The proposed method of IBPSO ensures optimal PMU placement with and without consideration of zero injection measurements. The proposed method has been applied to standard test systems like 17 bus, IEEE 24-bus, IEEE 30-bus, New England 39-bus, IEEE 57-bus system...

  19. Model-Based Throttle Control using Static Compensators and Pole Placement Commande des gaz basée sur un modèle utilisant des compensateurs statiques et un placement de pôles

    Directory of Open Access Journals (Sweden)

    Thomasson A.

    2011-10-01

    Full Text Available In modern spark ignited engines, the throttle is controlled by the Electronic Control Unit (ECU, which gives the ECU direct control of the air flow and thereby the engine torque. This puts high demands on the speed and accuracy of the controller that positions the throttle plate. The throttle control problem is complicated by two strong nonlinear effects, friction and limp-home torque. This paper proposes the use of two, simultaneously active, static compensators to counter these effects and approximately linearize the system. A PID controller is designed for the linearized system, where pole placement is applied to design the PD controller and a gain scheduled I-part is added for robustness against model errors. A systematic procedure for generating compensator and controller parameters from open loop experiments is also developed. The controller performance is evaluated both in simulation, on a throttle control benchmark problem, and experimentally. A robustness investigation pointed out that the limp-home position is an important parameter for the controller performance, this is emphasized by the deviations found in experiments. The proposed method for parameter identification achieves the desired accuracy. Au sein des moteurs à allumage commandé modernes, les gaz sont régulés par le boîtier de commande électronique (ECU; Electronic Control Unit, qui permet la régulation directe par l’ECU du flux d’air et ainsi du couple moteur. Cela conduit à des exigences élevées quant à la vitesse et à la précision du régulateur qui positionne le papillon des gaz. Le problème de commande des gaz est compliqué par deux forts effets non linéaires, le frottement et le couple de mode de secours (“limp-home”. Cet article propose l’utilisation de deux compensateurs statiques, actifs simultanément, pour contrer ces effets et linéariser approximativement le système. Un régulateur PID est conçu pour le système linéarisé, où un

  20. How do we facilitate international clinical placements for nursing students: A cross-sectional exploration of the structure, aims and objectives of placements.

    Science.gov (United States)

    Browne, Caroline A; Fetherston, Catherine M

    2018-07-01

    International clinical placements provide undergraduate students with a unique and complex clinical learning environment, to explore cultural awareness, experience different health care settings and achieve clinical competencies. Higher education institutions need to consider how to structure these placements to ensure appropriate and achievable aims and learning outcomes. In this study we described the structure, aims and learning outcomes associated with international clinical placement opportunities currently undertaken by Australian undergraduate nursing students in the Asia region. Forty eight percent (n = 18) of the institutions invited responded. Eight institutions met the inclusion criteria, one of which offered three placements in the region, resulting in 10 international placements for which data were provided. An online survey tool was used to collect data during August and September 2015 on international clinical placements conducted by the participating universities. Descriptive data on type and numbers of placements is presented, along with results from the content analysis conducted to explore data from open ended questions on learning aims and outcomes. One hundred students undertook 10 International Clinical Placements offered in the Asian region by eight universities. Variations across placements were found in the length of placement, the number of students participating, facilitator to student ratios and assessment techniques used. Five categories related to the aims of the programs were identified: 'becoming culturally aware through immersion', 'working with the community to promote health', 'understanding the role of nursing within the health care setting', 'translating theory into professional clinical practice', and 'developing relationships in international learning environments'. Four categories related to learning outcomes were identified: 'understanding healthcare and determinants of health', 'managing challenges', 'understanding the

  1. Study on Pole Arrangement of the CEDM Coils

    International Nuclear Information System (INIS)

    Park, Jin Seok; Lee, Myoung Goo; Kim, Hyun Min; Cho, Yeon Ho; Choi, Taek Sang

    2013-01-01

    The coil stack assembly is important for reliable operation of the CEDM, there have been efforts to improve the design by optimizing the design parameters such as dimensions and winding turns. However, magnetic forces of the CEDM can also change by different pole arrangement even if their design parameters are the same. Since the latch coil and lift coil are installed connected to each other, they produce magnetically coupled field when they are energized at the same time. This coupling field can affect the magnetic force of the CEDM significantly. In this paper, coil pole arrangement effects are studied. Electro-magnetic analysis is performed for the different pole arrangements of the CEDM coils to calculate the magnetic forces. Pole arrangement effects on magnetic forces were studied by static analysis of the CEDM magnetic field. Magnetic forces were calculated and compared for the two different pole arrangements of the coils. The results show that the magnetic poles of the lift coil and latch coil shall be arranged to have the same magnetic pole direction to achieve higher magnetic force

  2. An optimal PID controller via LQR for standard second order plus time delay systems.

    Science.gov (United States)

    Srivastava, Saurabh; Misra, Anuraag; Thakur, S K; Pandit, V S

    2016-01-01

    An improved tuning methodology of PID controller for standard second order plus time delay systems (SOPTD) is developed using the approach of Linear Quadratic Regulator (LQR) and pole placement technique to obtain the desired performance measures. The pole placement method together with LQR is ingeniously used for SOPTD systems where the time delay part is handled in the controller output equation instead of characteristic equation. The effectiveness of the proposed methodology has been demonstrated via simulation of stable open loop oscillatory, over damped, critical damped and unstable open loop systems. Results show improved closed loop time response over the existing LQR based PI/PID tuning methods with less control effort. The effect of non-dominant pole on the stability and robustness of the controller has also been discussed. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Percutaneous Placement of Central Venous Catheters: Comparing the Anatomical Landmark Method with the Radiologically Guided Technique for Central Venous Catheterization Through the Internal Jugular Vein in Emergent Hemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Koroglu, M.; Demir, M.; Koroglu, B.K.; Sezer, M.T.; Akhan, O.; Yildiz, H.; Yavuz, L.; Baykal, B.; Oyar, O. [Suleyman Demirel Univ., Isparta (Turkey). Depts. of Radiology, Internal Medicine and Anesthesiology

    2006-02-15

    Purpose: To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. Material and Methods: The study was performed prospectively in a randomized manner. The success and immediate complication rates of radiologically guided placement of central venous access catheters through the internal jugular vein (n = 40) were compared with those of the anatomical landmark method (n 40). The success of placement, the complications, the number of passes required, and whether a single or double-wall puncture occurred were also noted and compared. Results: The groups were comparable in age and sex. The indication for catheter placement was hemodialysis access in all patients. Catheter placement was successful in all patients in group 2 and unsuccessful in 1 (2.5%) patient in group 1. All catheters functioned adequately and immediately after the placement (0% initial failure rate) in group 2, but 3 catheters (7.5% initial failure rate) were non-functional just after placement in group 1. The total number of needle passes, double venous wall puncture, and complication rate were significantly lower in group 2. Conclusion: Percutaneous central venous catheterization via the internal jugular vein can be performed by interventional radiologists with better technical success rates and lower immediate complications. In conclusion, central venous catheterization for emergent dialysis should be performed under both real-time ultrasound and fluoroscopic guidance.

  4. Rotor pole refurbishment for hydrogenerators: insulation problems and solutions

    International Nuclear Information System (INIS)

    Reynolds, R.R.; Rux, L.

    2005-01-01

    Rotor poles for Unit 1 at Lower Granite Powerhouse were removed from the rotor and shipped to a repair facility for refurbishment. Upon inspection, it was found that all of the pole bodies exhibited a distinct bow, center to end, on the pole mounting surface. In some cases, the deflection was as much as 0.106 inch. Concerns were raised about how this condition might affect the ability to properly insulate and/or re-seat the poles. This paper presents details of the rotor pole and field winding evaluation, the problems encountered, and the solutions implemented to successfully refurbish the rotor poles and field winding. (author)

  5. Pole Dancing Auto-ethnography – Practice, Pedagogy, Performance

    Directory of Open Access Journals (Sweden)

    Amy Patricia Cadwallader

    2017-02-01

    Full Text Available In this research paper, the author addresses the following four questions: 1 What are the implications of bringing pole dancing into concert dance, not as a caricature or theatrical version of what is performed in strip clubs, but as its own, free-standing art form? 2 In what ways will years of ballet and modern dance training influence the type of dancing that emerges from dancers when poles and other apparatuses are introduced? 3 How can the author create an original pole dancing style and pedagogical methods for teaching it? 4 Who participates in pole fitness classes and how does the demographic change based on location? What about when pole fitness classes are offered in an academic setting? The author shares first-hand experiences of investigating pole dancing in fitness classes, attending performances, engaging in a rehearsal process with highly trained dancers, and teaching pole dancing to movers with a wide range of abilities. The author addresses how research plans changed as she encountered limitations of budget and time constraints. The author also elaborates on the creative process that she engaged in with her thesis cast, collaborators, and supporting designers in the making of Super-beneath, a theatrical dance work that uses five, free-standing poles. She outline the vignettes, overall structure, and narrative of the work. The author then discusses where this research fits into the larger field of pole dancing, and the even larger field of dance. In the final sections of this paper, the author describes her pedagogical practices relating to pole classes, what “practice as research” means to her, and how she would like to continue on this research trajectory in the future.

  6. Percutaneous placement of peritoneal port-catheter in oncologic patients

    International Nuclear Information System (INIS)

    Orsi, Franco; Vigna, Paolo Della; Bonomo, Guido; Penco, Silvia; Lovati, Elena; Bellomi, Massimo

    2004-01-01

    The aim of this paper is to describe the technique of percutaneous ultrasound (US)-guided placement of a peritoneal port-catheter in an interventional radiological setting. Nineteen patients with peritoneal carcinomatosis were selected for intraperitoneal port-catheter placement in order to perform intracavitary receptor-immuno- or radio-immunotherapy with Ytrium-90. All the procedures were performed percutaneously under US and fluoro guidance; the insertion site for catheters was chosen according to abdominal conditions and US findings: all devices were implanted at the lower abdominal quadrants. All patients were followed up with CT and US according to the therapy protocol. The procedure was successfully completed in 15/19 patients, in 4 being contraindicated by peritoneal adhesions. No procedure-related complications and device occlusions during therapy were observed; one catheter displaced 7 months later the placement. In our experience, this procedure was feasible, reliable and easy to perform, allowing the correct administration of the planned intracavitary therapy. Peritoneal adhesions are the main limitation of peritoneal port placement. (orig.)

  7. Muscular and metabolic responses to different Nordic walking techniques, when style matters.

    Science.gov (United States)

    Pellegrini, Barbara; Boccia, Gennaro; Zoppirolli, Chiara; Rosa, Raffaela; Stella, Federico; Bortolan, Lorenzo; Rainoldi, Alberto; Schena, Federico

    2018-01-01

    Due to poling action and upper body engagement, Nordic walking (NW) has additional health benefits with respect to conventional walking. The aim of this study was to evaluate the differences in muscle activation and metabolic responses between NW, performed with the technique suggested by NW instructors, and with some modifications in the way to move upper limb and poles. Ten NW instructors volunteered to walk on a treadmill at 5.5 km•h-1 in five conditions: walking (W), Nordic walking (NW), NW with a weak poling action (NWweak), with straight-upper limbs moving the shoulders (NWshoulder) and with elbow flexion-extension pattern and shoulder freezed (NWelbow). Poling forces, body segments and poles movement, upper and lower body muscle activation, as well as metabolic parameters were measured.All modified NW techniques elicited lower muscular activation and metabolic responses with respect to the suggested NW technique (P walking instructors, sport technicians and practitioners should be aware that any deviation from the technique usually suggested might lead to lower benefits. However it is worth to note that any walking technique with poles elicits higher metabolic responses and muscular activation than walking.

  8. Parallel algorithms for placement and routing in VLSI design. Ph.D. Thesis

    Science.gov (United States)

    Brouwer, Randall Jay

    1991-01-01

    The computational requirements for high quality synthesis, analysis, and verification of very large scale integration (VLSI) designs have rapidly increased with the fast growing complexity of these designs. Research in the past has focused on the development of heuristic algorithms, special purpose hardware accelerators, or parallel algorithms for the numerous design tasks to decrease the time required for solution. Two new parallel algorithms are proposed for two VLSI synthesis tasks, standard cell placement and global routing. The first algorithm, a parallel algorithm for global routing, uses hierarchical techniques to decompose the routing problem into independent routing subproblems that are solved in parallel. Results are then presented which compare the routing quality to the results of other published global routers and which evaluate the speedups attained. The second algorithm, a parallel algorithm for cell placement and global routing, hierarchically integrates a quadrisection placement algorithm, a bisection placement algorithm, and the previous global routing algorithm. Unique partitioning techniques are used to decompose the various stages of the algorithm into independent tasks which can be evaluated in parallel. Finally, results are presented which evaluate the various algorithm alternatives and compare the algorithm performance to other placement programs. Measurements are presented on the parallel speedups available.

  9. Percutaneous placement of ureteral stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hyup; Park, Jae Hyung; Han, Joon Koo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Antegrade placement of ureteral stents has successfully achieved in 41 of 46 ureters. When it was difficult to advance ureteral stents through the lesion, it was facilitated by retrograde guide-wire snare technique through urethra. Complications associated with the procedure were non-function of ureteral stent by occlusion, upward migration,and spontaneous fracture of ureteral stent. These complications were managed by percutaneous nephrostomy and removal of ureteral stents by guide-wire snare technique and insertion of a new ureteral stent. While blood cell in urine was markedly increased in about 50% of patients following the procedure.

  10. Solar Open Flux Migration from Pole to Pole: Magnetic Field Reversal.

    Science.gov (United States)

    Huang, G-H; Lin, C-H; Lee, L C

    2017-08-25

    Coronal holes are solar regions with low soft X-ray or low extreme ultraviolet intensities. The magnetic fields from coronal holes extend far away from the Sun, and thus they are identified as regions with open magnetic field lines. Coronal holes are concentrated in the polar regions during the sunspot minimum phase, and spread to lower latitude during the rising phase of solar activity. In this work, we identify coronal holes with outward and inward open magnetic fluxes being in the opposite poles during solar quiet period. We find that during the sunspot rising phase, the outward and inward open fluxes perform pole-to-pole trans-equatorial migrations in opposite directions. The migration of the open fluxes consists of three parts: open flux areas migrating across the equator, new open flux areas generated in the low latitude and migrating poleward, and new open flux areas locally generated in the polar region. All three components contribute to the reversal of magnetic polarity. The percentage of contribution from each component is different for different solar cycle. Our results also show that the sunspot number is positively correlated with the lower-latitude open magnetic flux area, but negatively correlated with the total open flux area.

  11. Laryngeal mask placement in a teaching institution: analysis of difficult placements [version 1; referees: 2 approved, 1 approved with reservations

    Directory of Open Access Journals (Sweden)

    Anastasia D Katsiampoura

    2015-04-01

    Full Text Available Background: Laryngeal mask airway (LMA placement is now considered a common airway management practice. Although there are many studies which focus on various airway techniques, research regarding difficult LMA placement is limited, particularly for anesthesiologist trainees. In our retrospective analysis we tried to identify predictive factors of difficult LMA placement in an academic training program. Methods: This retrospective analysis was derived from a research airway database, where data were collected prospectively at the Memorial Hermann Hospital, Texas Medical Center, Houston, TX, USA, from 2008 to 2010. All non-obstetric adult patients presenting for elective surgery requiring general anesthesia, were enrolled in this study: anesthesiology residents primarily managed the airways. The level of difficulty, number of attempts, and type of the extraglottic device placement were retrieved. Results: Sixty-nine unique Laryngeal Mask Airways (uLMAs were utilized as a primary airway device. Two independent predictors for difficult LMA placement were identified: gender and neck circumference. The sensitivity for one factor is 87.5% with a specificity of 50%. However with two risk factors, the specificity increases to the level of 93% and the sensitivity is 63%. Conclusion: In a large academic training program, besides uLMA not been used routinely, two risk factors for LMA difficulty were identified, female gender and large neck circumference. Neck circumference is increasingly being recognized as a significant predictor across the spectrum of airway management difficulties while female gender has not been previously reported as a risk factor for difficult LMA placement.

  12. Cross-poling textures in a lead zirconate titanate piezoelectric material

    International Nuclear Information System (INIS)

    Wan, Shan; Bowman, Keith J.

    2000-01-01

    Tetragonal ferroelectric materials are polarized to induce the anisotropy necessary for the piezoelectric effect. This poling of the material is inherently an orientation process. Pole figure texture measurements of poling and cross-poling in a lead zirconate titanate Navy VI material show domain motion. The resulting axisymmetric and three-dimensional textures demonstrate the contribution of 90 degree sign domain motion to piezoelectricity. Cross-poling results in strong orientations with lower applied fields than in the initial poling steps. (c) 2000 Materials Research Society

  13. Story Themes from the Family Distance Doll Placement Technique: A Method for Assessing Patterns of Closeness and Distance in Families of Disturbed and Normal Boys.

    Science.gov (United States)

    Gerber, Gwendolyn L.

    The diagnosis and evaluation of families applying for family therapy is necessary to identify problems in their relationships that can be effectively integrated into treatment. In the Family Distance Doll Placement technique, a diagnostic tool for assessing patterns of closeness and distance within the family, parents are asked to make up stories…

  14. Reuse of poles treated with CCA; CCA-kyllaestettyjen puupylvaeiden uudelleenkaeyttoe

    Energy Technology Data Exchange (ETDEWEB)

    Lehmus, E. [Vtt Building and Transport, Espoo (Finland)

    2005-07-01

    This study investigated the feasibility of re-using utility poles or parts of poles for structural use in construction. There are more than 10 million poles in Finland and about 200 000 poles will be removed from service yearly during the next few years. The directive 2003/2/EY will restrict the use of poles treated with CCA. This will change the practice that the energy and telecommunication companies have given the removed poles to the land owners. The present study launched by the Technical Research Centre of Finland (VTT) was carried out to determine the technical condition of CCA impregnated poles removed from service and the concentration levels and leaching of remaining preservatives. To summarize the results of the tests, it is safe to say that re-use of recovered poles of 30 to 50 years of age is possible. Both the preservative concentrations and strength/load-bearing capacity are high enough to allow the use of the poles as load-bearing structures. (orig.)

  15. The pole tide in deep oceans

    Science.gov (United States)

    Dickman, S. R.

    1990-01-01

    The fluid-dynamical theory of the pole tide is examined by describing the oceanic response to the Chandler wobble and assessing its implications for mantle anelasticity and low-frequency ocean dynamics. The Laplace tide equations accounting for bottom friction are given, and a spherical harmonic approach is delineated in which the time-independent portion of the tide height is expanded. Pole-tide height and related inertia products are linearly proportional to wobble amplitude, and the final equations are modified to account for mantle elasticity and oceanic loading. Results for pole tide effects are given for various earth models with attention to the role of boundary constraints. A dynamic effect is identified which lengthens the Chandler period by about 1 day more than static lengthening, a contribution that suggests a vigorous low-frequency response. The values derived are shown to agree with previous models that do not incorporate the effects of the pole tide.

  16. POLE mutations in families predisposed to cutaneous melanoma

    DEFF Research Database (Denmark)

    Aoude, Lauren G; Heitzer, Ellen; Johansson, Peter

    2015-01-01

    Germline mutations in the exonuclease domain of POLE have been shown to predispose to colorectal cancers and adenomas. POLE is an enzyme involved in DNA repair and chromosomal DNA replication. In order to assess whether such mutations might also predispose to cutaneous melanoma, we interrogated...... variants in the exonuclease domain of POLE. Although this frequency is not significantly higher than that in unselected Caucasian controls, we observed multiple cancer types in the melanoma families, suggesting that some germline POLE mutations may predispose to a broad spectrum of cancers, including...

  17. Plotter of pole figure using data from x-ray diffraction

    International Nuclear Information System (INIS)

    Lima, A.F.

    1990-01-01

    Any polycrystalline aggregate normally has a preferred crystallographic orientation, or texture which depends on its thermal and or mechanical history. Preferred orientation is best described by means of a pole figure. A pole figure is a stereographic projection which shows the variation in pole density with pole orientation, for a selected set of crystal planes. In this work, computer programs was developed to plot pole figures. The corrected intensities are calculated and directly transmitted to the plotter. The different intensities levels are represented by different colors in the pole figure. (author)

  18. Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts

    Energy Technology Data Exchange (ETDEWEB)

    Sane, S.S.; Towbin, A.; Bergey, E.A.; Kaye, R.D.; Fitz, C.R.; Albright, L.; Towbin, R.B. [Department of Radiology, Children`s Hospital of Pittsburgh, 3705 Fifth Avenue, Pittsburgh, PA 15213 (United States)

    1998-07-01

    Objective. The purpose of this study is to determine the risk of CNS and/or peritoneal infection in children with ventriculoperitoneal shunts in whom a percutaneous gastrostomy tube is placed. Materials and methods. We placed 205 gastrostomy or gastrojejunostomy tubes from January of 1991 to December 1996. Twenty-three patients (10 boys, 13 girls) had ventriculoperitoneal shunts at the time of placement. All shunts were placed at least 1 month prior to placement of the gastrostomy tube. The patients ranged in age from 8 months to 16 years with a mean age of 6 years, 9 months. Patient weight ranged from 2 kg to 60 kg. All 23 children required long-term nutritional support due to severe neurologic impairment. No prophylactic antibiotics were given prior to the procedure. Of the patients, 21/23 had a 14-F Sacks-Vine gastrostomy tube with a fixed terminal retention device inserted, using percutaneous fluoroscopic antegrade technique. Two of the 23 patients had a Ross 14-F Flexi-flo gastrostomy tube which required a retrograde technique due to a small caliber esophagus in these children. Results. All 23 children had technically successful placements of percutaneous gastrostomy (7) or gastrojejunostomy (16) tubes. Of the children, 21/23 (91 %) had no complications from the procedure. Two of 23 (9 %) patients demonstrated signs of peritonitis after placement of their gastrostomy tubes and subsequently had shunt infections. In both, children CSF culture grew gram-positive cocci. The antegrade technique was used in both children who developed peritonitis. Conclusion. Our study indicates children with ventriculoperitoneal shunts who undergo percutaneous gastrostomy are at greater risk for infection and subsequent shunt malfunction. Therefore, we recommend prophylactic antibiotic therapy to cover for skin and oral flora. (orig.) With 1 fig., 7 refs.

  19. The physiological and biomechanical differences between double poling and G3 skating in world class cross-country skiers.

    Science.gov (United States)

    Sandbakk, Øyvind; Leirdal, Stig; Ettema, Gertjan

    2015-03-01

    The current study compared differences in cycle characteristics, energy expenditure and peak speed between double poling (DP) and G3 skating. Eight world class male sprint skiers performed a 5-min submaximal test at 16 km h(-1) and an incremental test to exhaustion at a 5% incline during treadmill roller skiing with two different techniques: DP where all propulsion comes from poling, and G3 skating where leg skating is added to each double poling movement. Video analyses determined cycle characteristics; respiratory parameters and blood lactate concentration determined the physiological responses. G3 skating resulted in 16% longer cycle lengths at 16% lower cycle rates, whereas oxygen uptake was independent of technique during submaximal roller skiing. The corresponding advantages for G3 skating during maximal roller skiing were reflected in 14% higher speed, 30% longer cycle length at 16% lower cycle rate and 11% higher peak oxygen uptake (all p skating. This was done by major increases in cycle lengths at slightly lower cycle rates and a higher aerobic energy delivery. However, the oxygen uptake for a given submaximal speed was not affected by technique although higher cycle rate was used in DP.

  20. Interventional Radiology Techniques for Provision of Enteral Feeding

    International Nuclear Information System (INIS)

    Given, M.F.; Hanson, J.J.; Lee, M.J.

    2005-01-01

    Gastrostomy placement in patients who are unable to maintain their nutrition orally has been attempted using a variety of techniques over the past century. This includes surgical, endoscopic, and, more recently, percutaneous radiologically guided methods. Surgical gastrostomy placement was the method of choice for almost a century, but has since been superseded by both endoscopic and radiological placement. There are a number of indications for gastrostomy placement in clinical practice today, with fewer contraindications due to the recent innovations in technique placement and gastrostomy catheter type. We describe the technique of gastrostomy placement, which we use in our institution, along with appropriate indications and contraindications. In addition, we will discuss the wide variety of catheter types available and their perceived advantages. There remains some debate with regard to gastropexy performance and the use of primary gastrojejunal catheters, which we will address. In addition, we will discuss the advantages and disadvantages of the three major types of gastrostomy placement currently available (i.e., surgical, endoscopic, and radiological) and their associated complications

  1. Accuracy of pedicle screw placement in patients with Marfan syndrome.

    Science.gov (United States)

    Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong

    2017-03-21

    There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.

  2. Analyses of the Short Periodical Part of the Spectrum of Pole Coordinate Variations Determined by the Astrometric and Laser Technique

    Science.gov (United States)

    Kołaczek, B.; Kosek, W.; Galas, R.

    Series of BIH astrometric (BIH-ASTR) pole coordinates and of CSR LAGEOS laser ranging (CSR-LALAR) pole coordinates determined in the MERIT Campaign in the years 1972 - 1986, 1983 - 1986, respectively, have been filtered by different band pass filters consisting of the law pass Gauss filter and of the high pass Butterworth filter. Filtered residuals were analysed by the MESA-Maximum Entropy Spectra Analysis and by the Ormsby narrow band pass filters in order to find numerically modeled signals approximating these residuals in the best way.

  3. Alternative radiation-free registration technique for image-guided pedicle screw placement in deformed cervico-thoracic segments.

    Science.gov (United States)

    Kantelhardt, Sven R; Neulen, Axel; Keric, Naureen; Gutenberg, Angelika; Conrad, Jens; Giese, Alf

    2017-10-01

    Image-guided pedicle screw placement in the cervico-thoracic region is a commonly applied technique. In some patients with deformed cervico-thoracic segments, conventional or 3D fluoroscopy based registration of image-guidance might be difficult or impossible because of the anatomic/pathological conditions. Landmark based registration has been used as an alternative, mostly using separate registration of each vertebra. We here investigated a routine for landmark based registration of rigid spinal segments as single objects, using cranial image-guidance software. Landmark based registration of image-guidance was performed using cranial navigation software. After surgical exposure of the spinous processes, lamina and facet joints and fixation of a reference marker array, up to 26 predefined landmarks were acquired using a pointer. All pedicle screws were implanted using image guidance alone. Following image-guided screw placement all patients underwent postoperative CT scanning. Screw positions as well as intraoperative and clinical parameters were retrospectively analyzed. Thirteen patients received 73 pedicle screws at levels C6 to Th8. Registration of spinal segments, using the cranial image-guidance succeeded in all cases. Pedicle perforations were observed in 11.0%, severe perforations of >2 mm occurred in 5.4%. One patient developed a transient C8 syndrome and had to be revised for deviation of the C7 pedicle screw. No other pedicle screw-related complications were observed. In selected patients suffering from pathologies of the cervico-thoracic region, which impair intraoperative fluoroscopy or 3D C-arm imaging, landmark based registration of image-guidance using cranial software is a feasible, radiation-saving and a safe alternative.

  4. In Situ Poling and Imidization of Amorphous Piezoelectric Polyimides

    Science.gov (United States)

    Park, Cheol; Ounaies, Zoubeida; Wise, Kristopher E.; Harrison, Joycelyn S.; Bushnell, Dennis M. (Technical Monitor)

    2002-01-01

    An amorphous piezoelectric polyimide containing polar functional groups has been developed using a combination of experimental and molecular modeling for potential use in high temperature applications. This amorphous polyimide, (Beta-CN)APB/ODPA, has exhibited good thermal stability and piezoelectric response at temperatures up to 150C. Density functional calculations predicted that a partially cured amic acid (open imide ring) possesses a dipole moment four times larger than the fully imidized closed ring. In situ poling and imidization of the partially cured (Beta-CN)APB/ODPA, was studied in an attempt to maximize the degree of dipolar orientation and the resultant piezoelectric response. A positive corona poling was used to minimize localized arcing during poling and to allow use of higher poling fields without dielectric breakdown. The dielectric relaxation strength, remanent polarization, and piezoelectric response were evaluated as a function of the poling profile. The partially cured, corona poled polymers exhibited higher dielectric relaxation strength (delta varepsilon), remanent polarization (Pr) and piezoelectric strain coefficient (d33) than the fully cured, conventionally poled ones.

  5. A new technique for quantifying symmetry and opening angles in quartz c-axis pole figures: Implications for interpreting the kinematic and thermal properties of rocks

    Science.gov (United States)

    Hunter, N. J. R.; Weinberg, R. F.; Wilson, C. J. L.; Law, R. D.

    2018-07-01

    Variations in flow kinematics influence the type of crystallographic preferred orientations (CPOs) in plastically deformed quartz, yet we currently lack a robust means of quantifying the diagnostic symmetries that develop in the c-axis (0001) pole figure. In this contribution, we demonstrate how the symmetry of common c-axis topologies may be quantified by analysing the intensity distribution across a line transect of the pole figure margin. A symmetry value (S) measures the relative difference in intensities between marginal girdle maxima in the pole figure, and thus the degree to which the pole figure defines orthorhombic or monoclinic end member symmetries. This provides a semi-quantitative depiction of whether the rocks underwent coaxial or non-coaxial flow, respectively, and may subsequently be used to quantify other topological properties, such as the opening angle of girdle maxima. The open source Matlab® toolbox MTEX is used to quantify pole figure symmetries in quartzite samples from the Main Central Thrust (NW Himalaya) and the Moine Thrust (NW Scotland).

  6. At the Roots of Product Placement: The Mere Exposure Effect

    Directory of Open Access Journals (Sweden)

    Stefano Ruggieri

    2013-05-01

    Full Text Available The present study aims to analyze the effect of product placement on attitude change and takes into consideration psychological models of the mere exposure effect. A sample of high school students watched an excerpt from two widely-distributed movies in which several products were shown by using the technique known as product placement. The results indicate that students who saw the commercial brand liked the products more than those who didn’t see it. This effect, in line with the literature on the product placement effect, seems to be independent from the recognition of the brand in the movie excerpt. This study also shows that, in the high involvement condition, one exposure is enough to produce a positive attitude toward the brand.

  7. A poling study on lead zirconate titanate composition

    International Nuclear Information System (INIS)

    Bryant, P.J.

    1992-01-01

    Ceramics produced by the conventional mixed oxide route are dual phased. Because the titania and zirconia are not perfectly homogenized, some parts of the ceramic are more tetragonal (titanium rich) and other parts more rhombohedral (zirconium rich). This inhomogeneity means that some domains can be more easily poled than others. Lastly, the density and porosity can affect the poling process if the flaw density becomes such that the breakdown voltage is exceeded by the required poling voltage. The phase boundary determined by most dielectric and piezoelectric measurements is significantly removed from the 44% titanium content determined by neutron diffraction. The indicators that are most consistent with this value are the minimum in the poling efficiency curve and the shape of the dissipative factor curve. The reason for the discrepancy appears to be related to the broad coexistence region of the two phases and the differing poling efficiencies of each phase. It has been established that different poling temperature profiles can substantially modify the observed properties. Such behaviour is again related to the inhomogeneity of the ceramic and the presence of the two phases. 4 refs., 5 figs

  8. Energy efficient sensor nodes placement using Territorial Predator Scent Marking Algorithm (TPSMA)

    International Nuclear Information System (INIS)

    Abidin, H Z; Din, N M

    2013-01-01

    The positions of sensor nodes in a Wireless Sensor Network (WSN) must be able to provide maximum coverage with a longer lifetime. This paper proposed a sensor node placement technique that utilizes a new biologically inspired optimization technique that imitates the behavior of territorial predators in marking their territories with their odors known as Territorial Predator Scent Marking Algorithm (TPSMA). The TPSMA deployed in this paper uses the maximum coverage ratio as the objective function. The performance of the proposed technique is then compared with other schemes in terms of uniformity and average energy consumption. Simulation results show that the WSN deployed with the proposed sensor node placement scheme consumes lower energy compared to the other two schemes and is expected to provide longer lifetime.

  9. Thermal poling of multi-wire array optical fiber

    DEFF Research Database (Denmark)

    Huang, Lin; An, Honglin; Hayashi, Juliano G.

    2018-01-01

    We demonstrate in this paper thermal poling of multi-wire array fibers, which extends poling of fibers with two anodes to similar to 50 and similar to 500 wire array anodes. The second harmonic microscopy observations show that second order nonlinearity (SON) layers are developed surrounding all...... the rings of wires in the similar to 50 anode array fiber with poling of 1.8kV, 250 degrees C and 30min duration, and the outer rings of the similar to 500 anode array fiber at lower poling temperature. Our simulations based on a two-dimensional charge dynamics model confirm this can be explained...

  10. Unitary pole approximations and expansions in few-body systems

    International Nuclear Information System (INIS)

    Casel, A.; Haberzettl, H.; Sandhas, W.

    1982-01-01

    The unitary pole approximations or expansions of the two-body subsystem operators are well known, and particularly efficient and practical, methods to reduce the three-body problem to an effective two-body theory. In the present investigation we develop generalizations of these approximation techniques to the subsystem amplitudes of problems with higher particle numbers. They are based on the expansion of effective potentials which, in contrast to the genuine two-body interactions, are now energy dependent. Despite this feature our generalizations require only energy independent form factors, thus preserving one of the essential advantages of the genuine two-body approach. The application of these techniques to the four-body case is discussed in detail

  11. Self-Poling of BiFeO3 Thick Films.

    Science.gov (United States)

    Khomyakova, Evgeniya; Sadl, Matej; Ursic, Hana; Daniels, John; Malic, Barbara; Bencan, Andreja; Damjanovic, Dragan; Rojac, Tadej

    2016-08-03

    Bismuth ferrite (BiFeO3) is difficult to pole because of the combination of its high coercive field and high electrical conductivity. This problem is particularly pronounced in thick films. The poling, however, must be performed to achieve a large macroscopic piezoelectric response. This study presents evidence of a prominent and reproducible self-poling effect in few-tens-of-micrometer-thick BiFeO3 films. Direct and converse piezoelectric measurements confirmed that the as-sintered BiFeO3 thick films yield d33 values of up to ∼20 pC/N. It was observed that a significant self-poling effect only appears in cases when the films are heated and cooled through the ferroelectric-paraelectric phase transition (Curie temperature TC ∼ 820 °C). These self-poled films exhibit a microstructure with randomly oriented columnar grains. The presence of a compressive strain gradient across the film thickness cooled from above the TC was experimentally confirmed and is suggested to be responsible for the self-poling effect. Finally, the macroscopic d33 response of the self-poled BiFeO3 film was characterized as a function of the driving-field frequency and amplitude.

  12. Polymer poling characterization using second harmonic generation (SHG)

    Science.gov (United States)

    Tellier, Gildas; Averty, Dominique; Blart, Errol; Boisrobert, Christian; Gundel, Hartmut; Le Tacon, Sylvain; Monnereau, Cyrille; Odobel, Fabrice; Seveno, Raynald

    2006-04-01

    Several polymer molecules have structures which are suitable for the non-linear optic applications. We report on the design and fabrication of a high performance electro-optic modulator made of polymer thin films. The polymer we study contains a chromophore based on Disperse Red One covalently grafted to a host-matrix. The polymer materials are deposited in thin layers on a glass substrate by chemical solution deposition, either by spin-coating or by dip-coating. The thickness of the films is ranging from a hundred nanometers to several micrometers. Initially, the polymer molecules are randomly oriented and the films are isotropic, hence no electro-optic effect can be observed. In order to break the symmetry and align the chromophores, the films are submitted to the so-called corona poling process. As a result, their structure become non-centrosymmetric and the second-order susceptibility is no longer zero. The corona poling method consists of applying a high electric field to the polymer by means of a needle electrode, placed above the polymer film which is posed on a grounded sample support electrode. Thermal regulation of the support electrode allows to control the temperature during the poling of the films. Once the poling process has been established, a chemical cross-linking function is thermally activated in order to fix the orientation of the chromophores in the polymer matrix. The orientation and its stability in time is evaluated with a Second Harmonic Generation measurement set-up using the Makers Fringes configuration. We studied the influence of the poling temperature, the distance between the corona needle electrode and the sample, the high voltage applied, and the duration of the poling process on the efficiency of chromophore orientation in order to optimize the poling procedure. Finally, aging of poled polymer samples has been investigated at elevated temperatures, confirming the stability of the cross-linking process.

  13. Shock wave lithotripsy outcomes for lower pole and non-lower pole stones from a university teaching hospital: Parallel group comparison during the same time period

    Science.gov (United States)

    Geraghty, Robert; Burr, Jacob; Simmonds, Nick; Somani, Bhaskar K.

    2015-01-01

    Introduction: Shock wave lithotripsy (SWL) is a treatment option for all locations of renal and ureteric stones. We compared the results of SWL for lower pole renal stones with all other non-lower pole renal and ureteric stones during the same time period. Material and Methods: All SWL procedures were carried out as day case procedures by a mobile lithotripter from January 2012 to August 2013. The follow-up imaging was a combination of KUB X-ray or USS. Following SWL treatment, the stone free rate (SFR) was defined as ≤3 mm fragments. Results: A total of 148 patients with a mean age of 62 years underwent 201 procedures. Of the 201 procedures, 93 (46%) were for lower pole stones. The non-lower pole stones included upper pole (n = 36), mid pole (n = 40), renal pelvis (n = 10), PUJ (n = 8), mid ureter (n = 3), upper ureter (n = 5) and a combination of upper, middle and/or lower pole (n = 6). The mean stone size for lower pole stones (7.4 mm; range: 4-16 mm) was slightly smaller than non-lower pole stones (8 mm; range: 4-17 mm). The stone fragmentation was successful in 124 (62%) of patients. However, the SFR was statistically significantly better (P = 0.023) for non-lower pole stones 43 (40%) compared to lower pole stones 23 (25%). There were 9 (4%) minor complications and this was not significantly different in the two groups. Conclusions: Although SWL achieves a moderately high stone fragmentation rate with a low complication rate, the SFR is variable depending on the location of stone and the definition of SFR, with lower pole stones fairing significantly worse than stones in all other locations. PMID:25657543

  14. PNRA. South-pole directory listing

    OpenAIRE

    Biagioni, Stefania; Carlesi, Carlo; Carpen?, Andrea; Ramorino, Chiara; Rossi, Lucio

    1992-01-01

    In the following all DATA-SET descriptors (DSD) contained in the "South-Pole Directory" (vers. 1992) are listed. The "South-Pole Directory" was a joint project between ENEA and CNR. The IEI/CNR took care of the data digitalization and check and of the english translation (where necessary). The ARF/CNR and the Progetto Antartide/ENEA joined the IEI/CNR in defining the acronyms of the Sensor_Names and of the Source_Names, together with the short and long names for the Data_Centers. Finally, the...

  15. Frequency doubling in poled polymers using anomalous dispersion phase-matching

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczyk, T.C.; Singer, K.D. [Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Physics; Cahill, P.A. [Sandia National Labs., Albuquerque, NM (United States)

    1995-10-01

    The authors report on a second harmonic generation in a poled polymer waveguide using anomalous dispersion phase-matching. Blue light ({lambda} = 407 nm) was produced by phase-matching the lowest order fundamental and harmonic modes over a distance of 32 {micro}m. The experimental conversion efficiency was {eta} = 1.2 {times} 10{sup {minus}4}, in agreement with theory. Additionally, they discuss a method of enhancing the conversion efficiency for second harmonic generation using anomalous dispersion phase-matching to optimize Cerenkov second harmonic generation. The modeling shows that a combination of phase-matching techniques creates larger conversion efficiencies and reduces critical fabrication requirements of the individual phase-matching techniques.

  16. Cogging Torque Reduction Techniques for Spoke-type IPMSM

    Science.gov (United States)

    Bahrim, F. S.; Sulaiman, E.; Kumar, R.; Jusoh, L. I.

    2017-08-01

    A spoke-type interior permanent magnet synchronous motor (IPMSM) is extending its tentacles in industrial arena due to good flux-weakening capability and high power density. In many of the application, high strength of permanent magnet causes the undesirable effects of high cogging torque that can aggravate performance of the motor. High cogging torque is significantly produced by IPMSM due to the similar length and the effectiveness of the magnetic air-gap. The address of this study is to analyze and compare the cogging torque effect and performance of four common techniques for cogging torque reduction such as skewing, notching, pole pairing and rotor pole pairing. With the aid of 3-D finite element analysis (FEA) by JMAG software, a 6S-4P Spoke-type IPMSM with various rotor-PM configurations has been designed. As a result, the cogging torque effect reduced up to 69.5% for skewing technique, followed by 31.96%, 29.6%, and 17.53% by pole pairing, axial pole pairing and notching techniques respectively.

  17. Feasibility and Safety of Overtubes for PEG-Tube Placement in Patients with Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Crispin O. Musumba

    2015-01-01

    Full Text Available Background. Percutaneous endoscopic gastrostomy (PEG placement using the “pull” technique is commonly utilized for providing nutritional support in head and neck cancer (HNC patients, but it may be complicated by peristomal metastasis in up to 3% of patients. Overtube-assisted PEG placement might reduce this risk. However, this technique has not been systemically studied for this purpose to date. Methods. Retrospective analysis of consecutive patients with HNC who underwent overtube-assisted PEG placement at Westmead Hospital, Australia, between June 2011 and December 2013. Data were extracted from patients’ endoscopy reports and case notes. We present our technique for PEG insertion and discuss the feasibility and safety of this method. Results. In all 53 patients studied, the PEG tubes were successfully placed using 25 cm long flexible overtubes, in 89% prophylactically (before commencing curative chemoradiotherapy, and in 11% reactively (for treatment of tumor related dysphagia or weight loss. During a median follow-up period of 16 months, 3 (5.7% patients developed peristomal infection and 3 others developed self-limiting peristomal pain. There were no cases of overtube-related adverse events or overt cutaneous metastases observed. Conclusions. Overtube-assisted PEG placement in patients with HNC is a feasible, simple, and safe technique and might be effective for preventing cutaneous metastasis.

  18. Long-Term Bending Creep Behavior of Thin-Walled CFRP Tendon Pretensioned Spun Concrete Poles

    Directory of Open Access Journals (Sweden)

    Giovanni P. Terrasi

    2014-07-01

    Full Text Available This paper discusses the long-term behavior of a series of highly-loaded, spun concrete pole specimens prestressed with carbon fiber-reinforced polymer (CFRP tendons, which were subjected to outdoor four-point bending creep tests since 1996 in the frame of collaboration with the Swiss precast concrete producer, SACAC (Società Anonima Cementi Armati Centrifugati. The 2 m span cylindrical beams studied are models for lighting poles produced for the last 10 years and sold on the European market. Five thin-walled pole specimens were investigated (diameter: 100 mm; wall-thickness: 25–27 mm. All specimens were produced in a pretensioning and spinning technique and were prestressed by pultruded CFRP tendons. Initially, two reference pole specimens were tested in quasi-static four-point bending to determine the short-term failure moment and to model the short-term flexural behavior. Then, three pole specimens were loaded to different bending creep moments: while the lowest loaded specimen was initially uncracked, the second specimen was loaded with 50% of the short-term bending failure moment and exhibited cracking immediately after load introduction. The highest loaded pole specimen sustained a bending moment of 72% of the short-term bending failure moment for 16.5 years before failing in July 2013, due to the bond failure of the tendons, which led to local crushing of the high-performance spun concrete (HPSC. Besides this, long-term monitoring of the creep tests has shown a limited time- and temperature-dependent increase of the deflections over the years, mainly due to the creep of the concrete. A concrete creep-based model allowed for the calculation of the long-term bending curvatures with reasonable accuracy. Furthermore, the pole specimens showed crack patterns that were stable over time and minimal slippage of the tendons with respect to the pole’s end-faces for the two lower load levels. The latter proves the successful and durable

  19. Jupiter's interior and deep atmosphere: The initial pole-to-pole passes with the Juno spacecraft

    DEFF Research Database (Denmark)

    Bolton, S. J.; Adriani, Alberto; Adumitroaie, V.

    2017-01-01

    On 27 August 2016, the Juno spacecraft acquired science observations of Jupiter, passing less than 5000 kilometers above the equatorial cloud tops. Images of Jupiter's poles show a chaotic scene, unlike Saturn's poles. Microwave sounding reveals weather features at pressures deeper than 100 bars,...... of magnitude more precise. This has implications for the distribution of heavy elements in the interior, including the existence and mass of Jupiter's core. The observed magnetic field exhibits smaller spatial variations than expected, indicative of a rich harmonic content....

  20. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  1. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  2. Particles as S-matrix poles: hadron democracy

    International Nuclear Information System (INIS)

    Chew, G.F.

    1989-01-01

    The connection between two theoretical ideas of the 1950s is traced in this article, namely that hadrons are nonfundamental, ''composite'' particles and that all physically observable particles correspond to singularities of an analytic scattering matrix. The S matrix theory developed by Werner Heisenberg in the early forties now incorporated the concepts of unitarity, invariance, analyticity and causality. The meson-exchange force meant that poles must be present in nucleon-nuclear and pion-nucleon scattering as predicted by dispersion relations. Experimental work in accessible regions determined pole residues. Pole residue became associated with force strength and pole position with particle mass. In 1959, the author discovered the so-called ''bootstrap'' theory the rho meson as a force generates a rho particle. By the end of the 1950s it was clear that all hadrons had equal status, each being bound states of other hadrons, sustained by hadron exchange forces and that hadrons are self-generated by an S-matrix bootstrap mechanism that determines all their properties. (UK)

  3. Optimal placement of distributed generation in distribution networks ...

    African Journals Online (AJOL)

    This paper proposes the application of Particle Swarm Optimization (PSO) technique to find the optimal size and optimum location for the placement of DG in the radial distribution networks for active power compensation by reduction in real power losses and enhancement in voltage profile. In the first segment, the optimal ...

  4. The practice of pole dance as a leisure activity in Denmark

    DEFF Research Database (Denmark)

    Jensen, Andorra Lynn

    2015-01-01

    The aim of this study is to explore the how pole dance is practiced as a form of leisure activity in Denmark. The methodical approach is qualitative and inspired by ethnography. I have conducted a field study where I have observed and participated in the pole dance culture in Copenhagen from May ...... addresses the difference between a focus on dance and a focus on tricks in pole dancing as well as it examines the different opinions pole studio owners have concerning ‘sexiness’ in pole dance and how this affects the way pole dance is practiced....

  5. DETECTION AND CLASSIFICATION OF POLE-LIKE OBJECTS FROM MOBILE MAPPING DATA

    Directory of Open Access Journals (Sweden)

    K. Fukano

    2015-08-01

    Full Text Available Laser scanners on a vehicle-based mobile mapping system can capture 3D point-clouds of roads and roadside objects. Since roadside objects have to be maintained periodically, their 3D models are useful for planning maintenance tasks. In our previous work, we proposed a method for detecting cylindrical poles and planar plates in a point-cloud. However, it is often required to further classify pole-like objects into utility poles, streetlights, traffic signals and signs, which are managed by different organizations. In addition, our previous method may fail to extract low pole-like objects, which are often observed in urban residential areas. In this paper, we propose new methods for extracting and classifying pole-like objects. In our method, we robustly extract a wide variety of poles by converting point-clouds into wireframe models and calculating cross-sections between wireframe models and horizontal cutting planes. For classifying pole-like objects, we subdivide a pole-like object into five subsets by extracting poles and planes, and calculate feature values of each subset. Then we apply a supervised machine learning method using feature variables of subsets. In our experiments, our method could achieve excellent results for detection and classification of pole-like objects.

  6. Evidence of highly oxidizing environment over the South Pole

    International Nuclear Information System (INIS)

    Davis, D.

    2001-01-01

    Researchers at the Georgia Institute of Technology have discovered high levels of an air purifying chemical or oxidizing agent in the near-surface atmosphere over the South Pole. This research, funded by the National Science Foundation, has implications for interpreting historical global climate records stored in Antarctic ice cores. The hydroxyl (OH) radical is higher at the South Pole than that estimated from OH measurements recorded at the equator. The OH radical is vital to scrubbing pollution and naturally occurring chemicals from the air and prevents a buildup of toxic levels of chemicals. The near surface atmospheric zone is a highly oxidizing environment at the South Pole. There is evidence that oxidizing chemistry continues to occur in the buried snow. This active chemistry could modify chemical species before they are trapped in the ice in their final chemical forms. Therefore, glaciochemists who study climate change based on analysis of trace chemicals trapped in polar ice will have to be more careful in their interpretations of Antarctic ice cores. Any significant increase of nitric oxide levels in any snow-covered area should result in high OH levels. Scientists used the selected-ion chemical ionization mass spectrometer technique to measure OH. To measure nitric oxide (NO), they used chemiluminescence with modifications to improve its sensitivity. Nitric oxide is also a radical and is a by-product of internal combustion engines. At the South Pole, it is formed when ultraviolet radiation interacts with nitrate ions. The source of NO is not clear, but it may originate from stratospheric denitrification and the long-range transport of nitric acid formed at low latitude during electrical storms. Scientists are also working to better understand the oxidation of dimethyl sulfide (DMS) under the cold conditions and high latitudes of Antarctica. This information will help glaciochemists to better interpret sulfate and methane sulfonate concentrations

  7. Joint NetWork Reconfiguration and Capacitor Placement by Bactrial Foraging Algorithm

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Mohammadnia

    2011-01-01

    Full Text Available Power system engineers are forced to place more emphasis on reducing losses at the distribution level. From an economic perspective, Joint network reconfiguration and capacitor placement is one of the best ways to save energy. Application of heuristic technique is unavoidable, because of expansion of distribution networks and becoming more complex connections in these grids. In view of this, for the first this paper investigates the ability of Bacterial Foraging Algorithm (BFA for Joint network reconfiguration and capacitor placement.

  8. Asymptotic form factor of non-Abelian gauge theories, planar diagrammatics and complex poles as resonances in the analytic s-matrix

    International Nuclear Information System (INIS)

    Knight, D.W.

    1976-01-01

    Reasons are given for studying the form factor and a method for constructing all believed-to-be leading form factor diagrams in a certain class of non-Abelian gauge theories (NAGT's) in typical kinematic limits. The possibility that the form factor ''exponentiates'' in NAGT's (as it does in QED) is discussed. A method is given for constructing all 1CI planar diagrams (this is, all 1PI diagrams except those which separate upon cutting at a vertex) directly from one's heat--that is, without the need to refer to tables, et cetera. It is noted that the material is believed to be essentially completely original, that is, the technique for constructing all 1CI planar diagrams in an iterative fashion is completely new. Of course, one can construct them in an essentially random fashion, but this technique is slow and extremely error prone compared with the iterative technique given. The idea of associating an elastic resonance with a complex pole in the analytic scattering amplitude, T(E), is discussed. Calculations of the pole position and the residue of the Δ 33 resonance are given, along with an analysis of experimentally induced error in the pole position

  9. Treatment by stereotactic radiotherapy of tumoral injuries after implant placement: preliminary study

    International Nuclear Information System (INIS)

    Meingan, P.; Rio, E.; Labbe-Devilliers, C.; Geffroy, D.; Ricaud-Couprie, M.; Doutriaux-Dumoulin, I.

    2009-01-01

    Objective: to evaluate the interest and the place of stereotactic radiotherapy in the treatment of primitive or secondary tumoral injuries of the liver. To describe the technique of implants placement. Conclusion: the liver stereotactic radiotherapy, after implant placement, seems to be an alternative or complementary therapy to the radiofrequency for patients refused for surgery, with moderated side effects and a noticeable survival. Complementary studies, especially associated to radiofrequency must be considered. (N.C.)

  10. Pole orientation of 16 Psyche by two independent methods

    Science.gov (United States)

    Tedesco, E. F.; Taylor, R. C.

    1985-01-01

    Nineteen new lightcurves of 16 Psyche are presented along with a pole orientation derived using two independent methods, namely, photometric astrometry and magnitude-amplitude-shape-aspect. The pole orientations found using these two methods agree to within 4 deg. The results from applying photometric astrometry were prograde rotation, a sidereal period of 0.1748143 days + or - 0.0000003 days, and a pole at longitude 223 deg and latitude +37 deg, with an uncertainty of 10 deg, and, from applying magnitude-amplitude-shape-aspect a pole at 220 + or - 1 deg, +40 + or - 4 deg, and a modeled triaxial ellipsoid shape (a greater than b greater than c) and a/b = 1.33 + or - 0.07. The discrepancy between the high-pole latitude found here and the low latitudes reported by Lupishko et al. (1982) and Zhou and Yang (1982) is discussed.

  11. Current superimposition variable flux reluctance motor with 8 salient poles

    Science.gov (United States)

    Takahara, Kazuaki; Hirata, Katsuhiro; Niguchi, Noboru; Kohara, Akira

    2017-12-01

    We propose a current superimposition variable flux reluctance motor for a traction motor of electric vehicles and hybrid electric vehicles, which consists of 10 salient poles in the rotor and 12 slots in the stator. However, iron losses of this motor in high rotation speed ranges is large because the number of salient poles is large. In this paper, we propose a current superimposition variable flux reluctance motor that consists of 8 salient poles and 12 slots. The characteristics of the 10-pole-12-slot and 8-pole-12-slot current superimposition variable flux reluctance motors are compared using finite element analysis under vector control.

  12. Current superimposition variable flux reluctance motor with 8 salient poles

    Directory of Open Access Journals (Sweden)

    Takahara Kazuaki

    2017-12-01

    Full Text Available We propose a current superimposition variable flux reluctance motor for a traction motor of electric vehicles and hybrid electric vehicles, which consists of 10 salient poles in the rotor and 12 slots in the stator. However, iron losses of this motor in high rotation speed ranges is large because the number of salient poles is large. In this paper, we propose a current superimposition variable flux reluctance motor that consists of 8 salient poles and 12 slots. The characteristics of the 10-pole-12-slot and 8-pole-12-slot current superimposition variable flux reluctance motors are compared using finite element analysis under vector control.

  13. Cannula Versus Sharp Needle for Placement of Soft Tissue Fillers: An Observational Cadaver Study.

    Science.gov (United States)

    van Loghem, Jani A J; Humzah, Dalvi; Kerscher, Martina

    2017-12-13

    Soft-tissue fillers have become important products for facial rejuvenation. Deep fat compartments and facial bones lose volume during the natural aging process. For the most natural-looking results, deep volumetric injections at strategic sites are therefore preferred. Supraperiosteal placement is performed with a sharp needle or a non-traumatic cannula. The primary objective was to determine whether there is a difference in precision between supraperiosteal placement with a sharp needle compared with a non-traumatic cannula in cadaver specimens. A secondary objective was to analyze the safety profiles of both injection techniques. Cadaver heads were injected with dye material and soft-tissue fillers at multiple aesthetic facial sites on the supraperiosteum and subsequently dissected for observation of dye and filler placement. The non-traumatic cannula technique resulted in product being confined to the deep anatomic layers. In contrast, with the sharp needle technique, material was placed in multiple anatomic layers, from the periosteum to more superficial skin layers. For both techniques results were consistent for all facial sites. Although direct extrapolation from cadavers to the in vivo situation cannot be made, cannulae showed more precision in placement of product. With the sharp needle, the material was injected on the periosteum, and then migrated in a retrograde direction along the trajectory of the needle path, ending up in multiple anatomic layers. The sharp needle technique also showed a higher complication risk with intra-arterial injection occurring, even though the needle tip was positioned on the periosteum and the product was injected with the needle in constant contact with the periosteum. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  14. POLE somatic mutations in advanced colorectal cancer.

    Science.gov (United States)

    Guerra, Joana; Pinto, Carla; Pinto, Diana; Pinheiro, Manuela; Silva, Romina; Peixoto, Ana; Rocha, Patrícia; Veiga, Isabel; Santos, Catarina; Santos, Rui; Cabreira, Verónica; Lopes, Paula; Henrique, Rui; Teixeira, Manuel R

    2017-12-01

    Despite all the knowledge already gathered, the picture of somatic genetic changes in colorectal tumorigenesis is far from complete. Recently, germline and somatic mutations in the exonuclease domain of polymerase epsilon, catalytic subunit (POLE) gene have been reported in a small subset of microsatellite-stable and hypermutated colorectal carcinomas (CRCs), affecting the proofreading activity of the enzyme and leading to misincorporation of bases during DNA replication. To evaluate the role of POLE mutations in colorectal carcinogenesis, namely in advanced CRC, we searched for somatic mutations by Sanger sequencing in tumor DNA samples from 307 cases. Microsatellite instability and mutation analyses of a panel of oncogenes were performed in the tumors harboring POLE mutations. Three heterozygous mutations were found in two tumors, the c.857C>G, p.Pro286Arg, the c.901G>A, p.Asp301Asn, and the c.1376C>T, p.Ser459Phe. Of the POLE-mutated CRCs, one tumor was microsatellite-stable and the other had low microsatellite instability, whereas KRAS and PIK3CA mutations were found in one tumor each. We conclude that POLE somatic mutations exist but are rare in advanced CRC, with further larger studies being necessary to evaluate its biological and clinical implications. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  15. Development of a multi-pole magnetorheological brake

    International Nuclear Information System (INIS)

    Shiao, Yaojung; Nguyen, Quang-Anh

    2013-01-01

    This paper presents a new approach in the design and optimization of a novel multi-pole magnetorheological (MR) brake that employs magnetic flux more effectively on the surface of the rotor. MR brakes with conventional single ring-type electromagnetic poles have reached the limits of torque enhancement. One major reason is the limitation of the magnetic field strength within the active area of the MR fluid due to the geometric constraints of the coil. The multi-pole MR brake design features multiple electromagnetic poles surrounded by several coils. As a result, the active chaining areas for the MR fluid are greatly increased, and significant brake torque improvement is achieved. The coil structure, as a part of the stator, becomes flexible and customizable in terms of space usage for the winding and bobbin design. In addition, this brake offers extra options in its dimensions for torque enhancement because either the radial or the axial dimensions of the rotor can be increased. Magnetic circuit analysis was conducted to analyze the effects of the design parameters on the field torque. After that, simulations were done to find the optimal design under all major geometric constraints with a given power supply. The results show that the multi-pole MR brake provides a considerable braking torque increase while maintaining a compact and solid design. This is confirmation of its feasibility in actual braking applications. (paper)

  16. Fatigue failure and cracking in high mast poles.

    Science.gov (United States)

    2012-03-01

    This report presents the findings of a comprehensive research project to investigate the fatigue : cracking and failure of galvanized high mast illumination poles (HMIP). Ultrasonic inspection of : poles throughout the state has revealed the presence...

  17. Comparison of the incidence of intracranial hemorrhage in two different planning techniques for stereotactic electrode placement in the deep brain stimulation.

    Science.gov (United States)

    Piacentino, M; Zambon, G; Pilleri, M; Bartolomei, L

    2013-03-01

    Intracranial hemorrhage is an infrequent but potentially devastating complication associated with the placement of electrodes for deep brain stimulation (DBS). The objective of this retrospective review is to compare the risk of hemorrhage before and after the introduction of image-guided neuronavigation for the implant of electrodes for DBS. We reviewed all DBS implant performed at our Institute between 1998 and 2010. In 63 of the 106 patients, the targeting was based on ventriculography and merge of CT/MRI. After 2006, in the latter 43 procedures, we introduced targeting based on the merging of angio CT and MRI.. In both implant techniques, microelectrode recording (MER) was used to better define the target. All DBS procedures were performed by a single surgeon (M.P.). Patients had postoperative imaging (MRI or CT) 4-24 h following surgery. In the group of patients implanted with the first targeting technique, 3 hematomas occurred and all of them solved with sequelae (one residual weakness and two hemiplegias.) After the introduction of neuronavigator, 2 hemorrhages occurred, one solved without sequelae while the second resulted in epileptic seizures. Although the incidence of hemorrhage occurred before and after the use of neuronavigation is the same, the severity is lower in the neuronavigated procedures. Targeting based on the merging of CT angiography and MRI T1/T2 seemed to increase the safety of the lead placement reducing the risk of sequelae related to bleeding. The use of MER was not found to be correlated with an increased hemorrhage rate.

  18. Placement of acid spoil materials

    Energy Technology Data Exchange (ETDEWEB)

    Pionke, H B; Rogowski, A S

    1982-06-01

    Potentially there are several chemical and hydrologic problems associated with placement of acid spoil materials. The rationale for a deep placement well below the soil surface, and preferably below a water table, is to prevent or minimize oxidation of pyrite to sulfuric acid and associated salts by reducing the supply of oxygen. If, however, substantial sulfuric acid or associated salts are already contained within the spoil because of present or previous mining, handling and reclamation operations (or if large supplies of indigenous salts exist, placement below a water table) may actually increase the rate of acid and salt leaching. Specific placement of acid- and salt-containing spoil should be aimed at preventing contact with percolating water or rising water tables. We recommend placement based on chemical and physical spoil properties that may affect water percolation O/sub 2/ diffusion rates in the profile. Both the deeper placement of acid spoil and coarser particle size can substantially reduce the amount of acid drainage. Placement above the water table with emphasis on percolate control may be better for high sulfate spoils, while placement below the non-fluctuating water table may be better for pyritic spoils.

  19. Fibreglass as an alternative to wood poles : Transmission and distribution poles and crossarms : use of fiber reinforced composite materials for overhead electric utility lines

    Energy Technology Data Exchange (ETDEWEB)

    Wiles, J.R. [Shakespeare Composites and Electronics, Newberry, SC (United States)

    2002-07-01

    For over thirty years, Shakespeare Composites and Electronics has manufactured fiberglass composite lighting and utility poles, as well as being the number one maker of composite crossarms. Composite poles have a few advantages, such as being lightweight, they do no rust, are woodpecker and termite resistant, use no harmful chemicals, and have long life. A chart displaying the comparative pole weights is presented. The key design factors of fiberglass composite utility poles are: pole diameter, fiberglass type and wind angle, layers (thickness) of fiberglass, resin type and formulation, resin mix consistency, cure cycle and maximum curing temperature, and others. Two charts were also displayed presenting 40 feet class 4 pole bending strengths and 40 feet class 2 pole bending strengths. The author indicated that composite poles have a better strength consistency than wood, while being as consistent as steel and prestressed concrete. The design is based on an overload factor of safety of 2.5 for numerous installations. Some of the analytical methods used include mechanical testing, finite element modeling, and thermal analysis. The author describes in detail the concerns associated with attachments. Coating consists of a system of ultra violet blockers in the resin followed by an added resin rich polyester veil outer surface. In addition, there is a proprietary coating process with additional ultra violet blockers. Quality control is effected at the plant. The weathering system lasts 80 years. figs.

  20. RJMCMC based Text Placement to Optimize Label Placement and Quantity

    Science.gov (United States)

    Touya, Guillaume; Chassin, Thibaud

    2018-05-01

    Label placement is a tedious task in map design, and its automation has long been a goal for researchers in cartography, but also in computational geometry. Methods that search for an optimal or nearly optimal solution that satisfies a set of constraints, such as label overlapping, have been proposed in the literature. Most of these methods mainly focus on finding the optimal position for a given set of labels, but rarely allow the removal of labels as part of the optimization. This paper proposes to apply an optimization technique called Reversible-Jump Markov Chain Monte Carlo that enables to easily model the removal or addition during the optimization iterations. The method, quite preliminary for now, is tested on a real dataset, and the first results are encouraging.

  1. Generalized pole inflation: Hilltop, natural, and chaotic inflationary attractors

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Takahiro, E-mail: takahiro.terada@apctp.org [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan); Asia Pacific Center for Theoretical Physics, Pohang 37673 (Korea, Republic of)

    2016-09-10

    A reformulation of inflationary model analyses appeared recently, in which inflationary observables are determined by the structure of a pole in the inflaton kinetic term rather than the shape of the inflaton potential. We comprehensively study this framework with an arbitrary order of the pole taking into account possible additional poles in the kinetic term or in the potential. Depending on the setup, the canonical potential becomes the form of hilltop or plateau models, variants of natural inflation, power-law inflation, or monomial/polynomial chaotic inflation. We demonstrate attractor behaviors of these models and compute corrections from the additional poles to the inflationary observables.

  2. Development of a field pole of 1 MW-class HTS motor

    International Nuclear Information System (INIS)

    Yuan, S; Kimura, Y; Miki, M; Felder, B; Tsuzuki, K; Izumi, M; Ida, T; Umemoto, K; Aizawa, K; Yokoyama, M

    2010-01-01

    We report a field-pole high-temperature superconductor (HTS) magnet designed for 1 MW-class motor for propulsion. The field pole is assembled to the rotor of the radial-type motor. Each field pole is composed of HTS-Bi2223 tape wound into coils which have been piled up as a double pancake coils. In the design concept of the motor, we employ field poles without iron core. We prepared the test field-pole coil, whose dimension is smaller than the designed one for 1 MW, and tested its performances after cooling under self-field and external magnetic field. We verified the operation with the minimum bend radius of the coils required in the motor design, while keeping an optimal current which is lower than the critical current of the field-pole coil. The test HTS field poles were successfully cooled down and operated under a magnetic field ranging up to 5 T. We report the results of the test field-pole coil and the manufacture of a practical racetrack coil with Bi2223 and discuss the adaptability to 1 MW-class motors.

  3. Development of a field pole of 1 MW-class HTS motor

    Science.gov (United States)

    Yuan, S.; Kimura, Y.; Miki, M.; Felder, B.; Tsuzuki, K.; Ida, T.; Izumi, M.; Umemoto, K.; Aizawa, K.; Yokoyama, M.

    2010-06-01

    We report a field-pole high-temperature superconductor (HTS) magnet designed for 1 MW-class motor for propulsion. The field pole is assembled to the rotor of the radial-type motor. Each field pole is composed of HTS-Bi2223 tape wound into coils which have been piled up as a double pancake coils. In the design concept of the motor, we employ field poles without iron core. We prepared the test field-pole coil, whose dimension is smaller than the designed one for 1 MW, and tested its performances after cooling under self-field and external magnetic field. We verified the operation with the minimum bend radius of the coils required in the motor design, while keeping an optimal current which is lower than the critical current of the field-pole coil. The test HTS field poles were successfully cooled down and operated under a magnetic field ranging up to 5 T. We report the results of the test field-pole coil and the manufacture of a practical racetrack coil with Bi2223 and discuss the adaptability to 1 MW-class motors.

  4. Pole inflation in Jordan frame supergravity

    Energy Technology Data Exchange (ETDEWEB)

    Saikawa, Ken' ichi [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Yamaguchi, Masahide [Tokyo Institute of Technology, Ookayama (Japan). Dept. of Physics; Yamashita, Yasuho [Kyoto Univ. (Japan). Yukawa Inst. for Theoretical Physics; Yoshida, Daisuke [Montreal Univ., QC (Canada). Dept. of Physics

    2017-09-15

    We investigate inflation models in Jordan frame supergravity, in which an inflaton non-minimally couples to the scalar curvature. By imposing the condition that an inflaton would have the canonical kinetic term in the Jordan frame, we construct inflation models with asymptotically flat potential through pole inflation technique and discuss their relation to the models based on Einstein frame supergravity. We also show that the model proposed by Ferrara et al. has special position and the relation between the Kaehler potential and the frame function is uniquely determined by requiring that scalars take the canonical kinetic terms in the Jordan frame and that a frame function consists only of a holomorphic term (and its anti-holomorphic counterpart) for symmetry breaking terms. Our case corresponds to relaxing the latter condition.

  5. Pole inflation in Jordan frame supergravity

    International Nuclear Information System (INIS)

    Saikawa, Ken'ichi; Yamaguchi, Masahide; Yamashita, Yasuho; Yoshida, Daisuke

    2017-09-01

    We investigate inflation models in Jordan frame supergravity, in which an inflaton non-minimally couples to the scalar curvature. By imposing the condition that an inflaton would have the canonical kinetic term in the Jordan frame, we construct inflation models with asymptotically flat potential through pole inflation technique and discuss their relation to the models based on Einstein frame supergravity. We also show that the model proposed by Ferrara et al. has special position and the relation between the Kaehler potential and the frame function is uniquely determined by requiring that scalars take the canonical kinetic terms in the Jordan frame and that a frame function consists only of a holomorphic term (and its anti-holomorphic counterpart) for symmetry breaking terms. Our case corresponds to relaxing the latter condition.

  6. A method for estimating DMSA SPECT renal function for assessing the effect of percutaneous nephrolithotripsy on the treated pole

    International Nuclear Information System (INIS)

    AGUIAR, Pablo; RUIBAL, Álvaro; CORTÉS, Julia; PÉREZ-FENTES, Daniel; GARCÍA, Camilo; GARRIDO, Miguel

    2016-01-01

    The aim of this study was to develop a method for estimating DMSA SPECT renal function on each renal pole in order to evaluate the effect of percutaneous nephrolithotripsy by focusing the measurements on the region through which the percutaneous approach is performed. Twenty patients undergoing percutaneous nephrolithotripsy between November 2010 and June 2012 were included in this study. Both Planar and SPECT-DMSA studies were carried out before and after nephrolithotripsy. The effect of percutaneous nephrolithotripsy was evaluated by estimating the total renal function and the regional renal function of each renal pole. Despite PCNL has been previously reported as a minimally invasive technique, our results showed regional renal function decreases in the treated pole in most patients, affecting the total renal function in a few of them. A quantification method was used for estimating the SPECT DMSA renal function of the upper, inter polar and lower renal poles. Our results confirmed that total renal function was preserved after nephrolithotripsy. Nevertheless, the proposed method showed that the regional renal function of the treated pole decreased in most patients (15 of 20 patients), allowing us to find differences in patients who had not shown changes in the total renal function obtained from conventional quantification methods. In conclusion, a method for estimating the SPECT DMSA renal function focused on the treated pole enabled us to show for the first time that nephrolithotripsy can lead to a renal parenchymal damage restricted to the treated pole.

  7. Synthetic focused array of electrical prospecting using pole-pole array potential data; Sanjigen denki tansaho ni okeru nikyokuho den`i data wo mochiita denryu shusoku haichi no goseiho

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1997-10-22

    Various methods have been put into practice for the conventional two-dimensional pole configuration using a single line in three-dimensional electrical prospecting. Pole configuration effective for the three-dimensional exploration has not been investigated. This paper describes synthetic focused array using four pairs of guarded poles based on pole-pole array potential data in the case of arrangement of measuring points on a grid. Results of the numerical simulation are also described. For the focused array, laterolog of electrical logging is applied to the surface prospecting. Directivity can be given to the current from the main pole by controlling the current from guarded pole. It was found from the simulation that the resistivity anomaly is concentrated directly on the embedded ball for the focused array rather than for the pole-pole array. It was also found that two conductive balls can be clearly separated for the focused array rather than for the dipole-dipole array. Accordingly, it was considered that results approximating the original structures can be obtained by analyzing using the both arrays. 5 refs., 6 figs.

  8. Multiple pole in the electron--hydrogen-atom scattering amplitude

    International Nuclear Information System (INIS)

    Amusia, M.Y.; Kuchiev, M.Y.

    1982-01-01

    It is demonstrated that the amplitude for electron--hydrogen-atom forward scattering has the third-order pole at the point E = -13.6 eV, E being the energy of the incident electron. The coefficients which characterize the pole are calculated exactly. The invalidity of the Born approximation is proved. The contribution of the pole singularity to the dispersion relation for the scattering amplitude is discussed

  9. A genetic algorithm for optimizing multi-pole Debye models of tissue dielectric properties

    International Nuclear Information System (INIS)

    Clegg, J; Robinson, M P

    2012-01-01

    Models of tissue dielectric properties (permittivity and conductivity) enable the interactions of tissues and electromagnetic fields to be simulated, which has many useful applications in microwave imaging, radio propagation, and non-ionizing radiation dosimetry. Parametric formulae are available, based on a multi-pole model of tissue dispersions, but although they give the dielectric properties over a wide frequency range, they do not convert easily to the time domain. An alternative is the multi-pole Debye model which works well in both time and frequency domains. Genetic algorithms are an evolutionary approach to optimization, and we found that this technique was effective at finding the best values of the multi-Debye parameters. Our genetic algorithm optimized these parameters to fit to either a Cole–Cole model or to measured data, and worked well over wide or narrow frequency ranges. Over 10 Hz–10 GHz the best fits for muscle, fat or bone were each found for ten dispersions or poles in the multi-Debye model. The genetic algorithm is a fast and effective method of developing tissue models that compares favourably with alternatives such as the rational polynomial fit. (paper)

  10. Laparoscopic feeding jejunostomy: also a simple technique.

    Science.gov (United States)

    Albrink, M H; Foster, J; Rosemurgy, A S; Carey, L C

    1992-01-01

    Placement of feeding tubes is a common procedure for general surgeons. While the advent of percutaneous endoscopic gastrostomy has changed and improved surgical practice, this technique is contraindicated in many circumstances. In some patients placement of feeding tubes in the stomach may be contraindicated due to the risks of aspiration, gastric paresis, or gastric dysmotility. We describe a technique of laparoscopic jejunostomy tube placement which is easy and effective. It is noteworthy that this method may be used in patients who have had previous abdominal operations, and it has the added advantage of a direct peritoneal view of the viscera. We suggest that qualified laparoscopic surgeons learn the technique of laparoscopic jejunostomy.

  11. Analytical transmissibility based transfer path analysis for multi-energy-domain systems using four-pole parameter theory

    Science.gov (United States)

    Mashayekhi, Mohammad Jalali; Behdinan, Kamran

    2017-10-01

    The increasing demand to minimize undesired vibration and noise levels in several high-tech industries has generated a renewed interest in vibration transfer path analysis. Analyzing vibration transfer paths within a system is of crucial importance in designing an effective vibration isolation strategy. Most of the existing vibration transfer path analysis techniques are empirical which are suitable for diagnosis and troubleshooting purpose. The lack of an analytical transfer path analysis to be used in the design stage is the main motivation behind this research. In this paper an analytical transfer path analysis based on the four-pole theory is proposed for multi-energy-domain systems. Bond graph modeling technique which is an effective approach to model multi-energy-domain systems is used to develop the system model. In this paper an electro-mechanical system is used as a benchmark example to elucidate the effectiveness of the proposed technique. An algorithm to obtain the equivalent four-pole representation of a dynamical systems based on the corresponding bond graph model is also presented in this paper.

  12. Live imaging of spindle pole disorganization in docetaxel-treated multicolor cells

    International Nuclear Information System (INIS)

    Sakaushi, Shinji; Nishida, Kumi; Minamikawa, Harumi; Fukada, Takashi; Oka, Shigenori; Sugimoto, Kenji

    2007-01-01

    Treatment of cells with docetaxel at low concentrations induces aberrant bipolar spindles of which two centrosomes stay at only one pole, and also induces multipolar spindles. To gain insight into the relations between centrosome impairment and structural defects of the spindle, live-cell imaging was performed on a human MDA Auro/imp/H3 cell line in which centrosomes/mitotic spindles, nuclear membrane and chromatin were simultaneously visualized by fluorescent proteins. In the presence of docetaxel at IC 50 concentration, the centrosomes did not segregate, and multiple aster-like structures ectopically arose around the disappearing nuclear membrane. Those ectopic structures formed an acentrosomal pole opposing to the two-centrosomes-containing pole. In late metaphase, one pole often fragmented into multiple spindle poles, leading multipolar division. These results suggest that spindle pole fragility may be induced by centrosome impairment, and collapse of the pole may contribute to induction of aneuploid daughter cells

  13. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique

    Science.gov (United States)

    Wang, Jun-Qiang; Wang, Yu; Feng, Yun; Han, Wei; Su, Yong-Gang; Liu, Wen-Yong; Zhang, Wei-Jun; Wu, Xin-Bao; Wang, Man-Yi; Fan, Yu-Bo

    2017-01-01

    Background: Sacroiliac (SI) screw fixation is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot™ is an orthopedic surgery robot which can be used for SI screw fixation. This study aimed to evaluate the accuracy of robot-assisted placement of SI screws compared with a freehand technique. Methods: Thirty patients requiring posterior pelvic ring stabilization were randomized to receive freehand or robot-assisted SI screw fixation, between January 2016 and June 2016 at Beijing Jishuitan Hospital. Forty-five screws were placed at levels S1 and S2. In both methods, the primary end point screw position was assessed and classified using postoperative computed tomography. Fisher's exact probability test was used to analyze the screws’ positions. Secondary end points, such as duration of trajectory planning, surgical time after reduction of the pelvis, insertion time for guide wire, number of guide wire attempts, and radiation exposure without pelvic reduction, were also assessed. Results: Twenty-three screws were placed in the robot-assisted group and 22 screws in the freehand group; no postoperative complications or revisions were reported. The excellent and good rate of screw placement was 100% in the robot-assisted group and 95% in the freehand group. The P value (0.009) showed the same superiority in screw distribution. The fluoroscopy time after pelvic reduction in the robot-assisted group was significantly shorter than that in the freehand group (median [Q1, Q3]: 6.0 [6.0, 9.0] s vs. median [Q1, Q3]: 36.0 [21.5, 48.0] s; χ2 = 13.590, respectively, P < 0.001); no difference in operation time after reduction of the pelvis was noted (χ2 = 1.990, P = 0.158). Time for guide wire insertion was significantly shorter for the robot-assisted group than that for the freehand group (median [Q1, Q3]: 2.0 [2.0, 2.7] min vs. median [Q1, Q3]: 19.0 [15.5, 45.0] min; χ2 = 20.952, respectively, P < 0.001). The number of guide

  14. POLE-LIKE STREET FURNITURE DECOMPOSTION IN MOBILE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    F. Li

    2016-06-01

    Full Text Available Automatic semantic interpretation of street furniture has become a popular topic in recent years. Current studies detect street furniture as connected components of points above the street level. Street furniture classification based on properties of such components suffers from large intra class variability of shapes and cannot deal with mixed classes like traffic signs attached to light poles. In this paper, we focus on the decomposition of point clouds of pole-like street furniture. A novel street furniture decomposition method is proposed, which consists of three steps: (i acquirement of prior-knowledge, (ii pole extraction, (iii components separation. For the pole extraction, a novel global pole extraction approach is proposed to handle 3 different cases of street furniture. In the evaluation of results, which involves the decomposition of 27 different instances of street furniture, we demonstrate that our method decomposes mixed classes street furniture into poles and different components with respect to different functionalities.

  15. Pole-Like Street Furniture Decompostion in Mobile Laser Scanning Data

    Science.gov (United States)

    Li, F.; Oude Elberink, S.; Vosselman, G.

    2016-06-01

    Automatic semantic interpretation of street furniture has become a popular topic in recent years. Current studies detect street furniture as connected components of points above the street level. Street furniture classification based on properties of such components suffers from large intra class variability of shapes and cannot deal with mixed classes like traffic signs attached to light poles. In this paper, we focus on the decomposition of point clouds of pole-like street furniture. A novel street furniture decomposition method is proposed, which consists of three steps: (i) acquirement of prior-knowledge, (ii) pole extraction, (iii) components separation. For the pole extraction, a novel global pole extraction approach is proposed to handle 3 different cases of street furniture. In the evaluation of results, which involves the decomposition of 27 different instances of street furniture, we demonstrate that our method decomposes mixed classes street furniture into poles and different components with respect to different functionalities.

  16. Compact high-field superconducting quadrupole magnet with holmium poles

    Energy Technology Data Exchange (ETDEWEB)

    Barlow, D.B.; Kraus, R.H. Jr.; Lobb, C.T.; Menzel, M.T. (Los Alamos National Lab., NM (United States)); Walstrom, P.L. (Grumman Space Systems, Los Alamos, NM (United States))

    1992-03-15

    A compact high-field superconducting quadrupole magnet was designed and built with poles made of the rare-earth metal holmium. The magnet is intended for use in superconducting coupled-cavity linear accelerators where compact high-field quadrupoles are needed, but where the use of permanent magnets is ruled out because of trapped-flux losses. The magnet has a clear bore diameter of 1.8 cm, outside diameter of 11 cm, length of 11 cm, and pole tip length of 6 cm. The effect of using holmium, a material with a higher saturation field than iron, was investigated by replacing poles made of iron with identical poles made of holmium. The magnet was operated at a temperature of 4.2 K and reached a peak quadrupole field gradient of 355 T/m, a 10% increase over the same magnet with iron poles. This increase in performance is consistent with calculations based on B-H curves that were measured for holmium at 4.2 K. (orig.).

  17. Creating Esthetic Harmony with Nonloading, Fixed Provisional Restoration using Extracted Teeth after Immediate Implant Placement.

    Science.gov (United States)

    Satwalekar, Parth; Satwalekar, Tanushree; Bondugula, Vasanthi; Bhuvaneshwari, B; Harshavardhan, K V; Pasula, Kiran

    2016-04-01

    To make use of fiber-reinforced composite and the patient's own extracted teeth in fabricating a provisional restoration following immediate implant placement. Fiber-reinforced composites offer various possibilities in temporization of osseointegrating implants in the esthetic zone. In this chairside technique, the patient's own extracted teeth with fiber-reinforced composite were used to fabricate a provisional restoration after immediate implant placement. A putty index was made before extracting the teeth and placing the implants as planned. The index and crowns of the extracted teeth were used to make a nonloading, esthetic, chair-side provisional restoration after immediate implant placement. By using the patient's own teeth for pro-visionalization immediately after implant placement, acceptance is greatly enhanced.

  18. Elemental Mercury Diffusion Processes and Concentration at the Lunar Poles

    Science.gov (United States)

    Moxley, Frederick; Killen, Rosemary M.; Hurley, Dana M.

    2011-01-01

    In 2009, the Lyman Alpha Mapping Project (LAMP) spectrograph onboard the Lunar Reconnaissance Orbiter (LRO) spacecraft made the first detection of element mercury (Hg) vapor in the lunar exosphere after the Lunar Crater Observing and Sensing Satellite (LCROSS) Centaur rocket impacted into the Cabeus crater in the southern polar region of the Moon. The lunar regolith core samples from the Apollo missions determined that Hg had a devolatilized pattern with a concentration gradient increasing with depth, in addition to a layered pattern suggesting multiple episodes of burial and volatile loss. Hg migration on the lunar surface resulted in cold trapping at the poles. We have modeled the rate at which indigenous Hg is lost from the regolith through diffusion out of lunar grains. We secondly modeled the migration of Hg vapor in the exosphere and estimated the rate of cold-trapping at the poles using a Monte Carlo technique. The Hg vapor may be lost from the exosphere via ionization, Jeans escape, or re-impact into the surface causing reabsorption.

  19. Why good placements matter: Pre-placement and placement risk factors associated with mental health disorders in pre-school children in foster care.

    Science.gov (United States)

    Hillen, Thomas; Gafson, Leonie

    2015-07-01

    Pre-school children placed in local authority care show elevated rates of mental health disorders when compared to the general population. This study investigated risk factors for mental health disorders relating to the period prior to entering care and while in care. A representative sample of 43 children in care aged 0-72 months in an inner London borough underwent comprehensive multidimensional assessments. Presence of emotional, behavioural, attachment and adaptive disorders was ascertained. Exposure to two pre-placement risk factors and six placement risk factors was compared between children with and without a disorder. A total of 26 children (60.5%) had at least one mental health disorder. The two pre-placement risk factors, multiple types of maltreatment and entry into care after the age of 6 months, were both significantly associated with mental health disorders. The three placement risk factors of sudden placement moves, multiple placement moves and child-carer alienation showed a significant association with mental health disorders. There was a strong correlation between the number of risk factors and the number of co-morbid mental health disorders per child (r = .67, p school mental health. © The Author(s) 2014.

  20. STUDENT PREDICTION SYSTEM FOR PLACEMENT TRAINING USING FUZZY INFERENCE SYSTEM

    Directory of Open Access Journals (Sweden)

    Ravi Kumar Rathore

    2017-04-01

    Full Text Available Proposed student prediction system is most vital approach which may be used to differentiate the student data/information on the basis of the student performance. Managing placement and training records in any larger organization is quite difficult as the student number are high; in such condition differentiation and classification on different categories becomes tedious. Proposed fuzzy inference system will classify the student data with ease and will be helpful to many educational organizations. There are lots of classification algorithms and statistical base technique which may be taken as good assets for classify the student data set in the education field. In this paper, Fuzzy Inference system has been applied to predict student performance which will help to identify performance of the students and also provides an opportunity to improve to performance. For instance, here we will classify the student’s data set for placement and non-placement classes.

  1. IMF sector behavior estimated from geomagnetic data at South Pole

    International Nuclear Information System (INIS)

    Matsushita, S.; Xu, W.h.

    1981-01-01

    IMF sector behavior which has previously been estimated from the geomagnetic data at Godhavn is confirmed by study of the data at South Pole for 1959--1970 with the same estimation technique, taking the difference between northern and southern hemispheres into consideration. A method to improve (about 18%) the agreement between assigned and actual sector structures by study of the data at the two stations is suggested. Geomagnetic disturbance effects on sector estimation are discussed, and reversed sector effects in winter are given special emphasis

  2. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique

    NARCIS (Netherlands)

    Hattingh, A.C.; Bruyn, H. de; Ackermann, A.; Vandeweghe, S.

    2018-01-01

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with

  3. Reliability assessment of power pole infrastructure incorporating deterioration and network maintenance

    International Nuclear Information System (INIS)

    Ryan, Paraic C.; Stewart, Mark G.; Spencer, Nathan; Li, Yue

    2014-01-01

    There is considerable investment in timber utility poles worldwide, and there is a need to examine the structural reliability and probability based management optimisation of these power distribution infrastructure elements. The work presented in this paper builds on the existing studies in this area through assessment of both treated and untreated timber power poles, with the effects of deterioration and network maintenance incorporated in the analysis. This more realistic assessment approach, with deterioration and maintenance considered, was achieved using event-based Monte Carlo simulation. The output from the probabilistic model is used to illustrate the importance of considering network maintenance in the time-dependent structural reliability assessment of timber power poles. Under wind load, treated and untreated poles designed and maintained in accordance with existing Australian standards were found to have similar failure rates. However, untreated pole networks required approximately twice as many maintenance based pole replacements to sustain the same level of reliability. The effect of four different network maintenance strategies on infrastructure performance was also investigated herein. This assessment highlighted the fact that slight alterations to network maintenance practices can lead to significant changes in performance of timber power pole networks. - Highlights: • A time-dependent structural reliability model was developed for timber power poles. • Deterioration and network maintenance were incorporated into this event based model. • Network maintenance had a significant impact on power pole wind vulnerability. • Treated and untreated poles designed to Australian standards had similar reliability. • Minor alterations to maintenance strategies had large effects on network performance

  4. Determination of the crystallite orientation distribution from direct pole figures

    International Nuclear Information System (INIS)

    Araujo Gomes, P.A.M. de.

    1977-01-01

    A method is described which allows to calculate the crystallite orientation distribution in polycrystalline material, from direct pole figures data of its crystallographic planes (Roe's Method). The programme was applied to (1010), (0002), (1011) and (1120) complete pole figures data for a commercial, thin sheet Zircaloy-4 tubing specimen. A semi-automatic Rigaku-Denki texture goniometer, which scans the reciprocal lattice sphere pointwise outputting the data in a punched tape, was used to obtain the pole figures. This is consistent with the results obtained through direct conclusion from the pole figures. (author)

  5. Sediment Placement Areas 2012

    Data.gov (United States)

    California Natural Resource Agency — Dredge material placement sites (DMPS), including active, inactive, proposed and historical placement sites. Dataset covers US Army Corps of Engineers San Francisco...

  6. Sediment Placement Areas 2012

    Data.gov (United States)

    California Department of Resources — Dredge material placement sites (DMPS), including active, inactive, proposed and historical placement sites. Dataset covers US Army Corps of Engineers San Francisco...

  7. Modern methods of experimental construction of texture complete direct pole figures by using X-ray data

    Science.gov (United States)

    Isaenkova, M.; Perlovich, Yu; Fesenko, V.

    2016-04-01

    Currently used methods for constructing texture complete direct pole figure (CDPF) based on the results of X-ray diffractometric measurements were considered with respect to the products of Zr-based alloys and, in particular, used in a nuclear reactor cladding tubes, for which the accuracy of determination of integral texture parameters is of the especial importance. The main attention was devoted to technical issues which are solved by means of computer processing of large arrays of obtained experimental data. Among considered questions there are amendments of the defocusing, techniques for constructing of complete direct pole figures and determination of integral textural parameters. The methods of reconstruction of complete direct pole figures by partial direct pole figures recorded up to tilt angles of sample ψ=70-80°: the method of extrapolation of data to an uninvestigated region of the stereographic projection, and the method of "sewing" of partial pole figures measured for three mutually perpendicular plane sections of the product. The limits of applicability of these methods, depending on the shape of the test product and the degree of inhomogeneity of the layer-by-layer texture, were revealed. On the basis of a large number of experimental data, the accuracy of the integral parameters used for calculation of the physical and mechanical properties of metals with a hexagonal crystal structure was found to be equal to 0.02, when taking into account the texture heterogeneity of regular products from Zr-based alloys.

  8. Theoretical modeling and experimental analyses of laminated wood composite poles

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; Vijaya Gopu; Chung Y. Hse

    2005-01-01

    Wood laminated composite poles consist of trapezoid-shaped wood strips bonded with synthetic resin. The thick-walled hollow poles had adequate strength and stiffness properties and were a promising substitute for solid wood poles. It was necessary to develop theoretical models to facilitate the manufacture and future installation and maintenance of this novel...

  9. Percutaneous catheter drainage of thoracic fluid: the usefulness and safety of bedside trocar placement under ultrasound guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Heon [Seoul Medical Center, Seoul (Korea, Republic of)

    2006-07-15

    The author wanted to evaluate the usefulness and safety of the trocar technique for US-guided bedside catheter placement into thoracic fluid collections, and this technique has generally been reserved for the larger or superficial fluid collections. 42 drainage procedures were performed in 38 patients at the bedside. The patients were positioned supine or semi-upright. A drainage catheter system with a stylet and cannula assembly was used and all of the catheters were inserted using the trocar technique. The procedures consisted of drainage of empyema (n=14), malignant effusion (n=13), lung abscess (n=3), massive transudate (n=8), hemothorax (n=2) and chest wall hematoma (n=2). The clinical results were classified as successful (complete and partially successful), failure or undetermined. The medical records and images were retrospectively reviewed to evaluate the success rate, the complications and the procedure time. Technical success was achieved in all of the 42 procedures. With using the trocar technique, all the catheters were placed into even the small collections without significant complications. Drainage was successful in 36 (85.7%) of the 42 procedures. The average volume of thoracic fluid that was aspirated manually at the time of catheter placement was 420 mL (range: 35 to 1470 mL). The procedure time was less than 10 minutes from US-localization to complete catheter placement in all of the procedures. The trocar technique under US guidance can be an efficient and safe alternative to the Seldinger or guide-wire exchange technique for bedside catheter placement in the critically ill or hemodynamically unstable patients.

  10. Derivation of nominal strength for wood utility poles

    Science.gov (United States)

    Ronald W. Wolfe; Jozsef Bodig; Patricia Lebow

    2001-01-01

    The designated fiber stress values published in the American National Standards Institute Standard for Poles, ANSI 05.1, no longer reflect the state of the knowledge. These values are based on a combination of test data from small clear wood samples and small poles (

  11. Low-profile stent placement with the monorail technique for treatment of renal artery stenosis: midterm results of a prospective trial.

    Science.gov (United States)

    Müller-Hülsbeck, Stefan; Frahm, Christian; Behm, Charlotte; Schäfer, Phillip Jobst; Bolte, Hendrik; Heller, Martin; Jahnke, Thomas

    2005-07-01

    To determine feasibility, safety, and midterm patency of a monorail balloon stent device for the treatment of renal artery stenosis (RAS). During a period of 30 months, 47 patients (with severe hypertension, n=45; renal insufficiency, n=20) with 50 cases of RAS and indications for stent implantation (calcified ostial lesion, n=41; insufficient percutaneous transluminal angioplasty, n=6; dissection, n=3) were enrolled into the prospective evaluation. After predilation, 59 stents (Rx-Herculink 4 mm, n=2; 5 mm, n=19; 6 mm, n=35; 7 mm, n=3) were implanted under manometer control with use of the long-sheath technique (5 F; 6 F for 7-mm stents) via a femoral (n=44) or transbrachial approach (n=6). Parameters of hypertension and renal insufficiency were determined before and after the procedure and for a maximum of 18 months. Restenosis rate was determined with color duplex ultrasonography. Renal artery stent placement (mean diameter, 5.7 mm; mean length, 16 mm) was technically successful in all cases (100%). Mean blood pressure and serum creatinine level decreased from 177/93 mm Hg to 145/78 mm Hg and from 1.8 mg/dL to 1.5 mg/dL, respectively. Within 48 hours after the implantation, acute occlusions occurred in two patients, supposedly triggered by cholesterol embolization. Primary and primary assisted patency rates were 87% and 92% at 6 months and 75% and 84% at 18 months. Renal artery stent placement with the rapid-exchange monorail system is a safe procedure with promising patency rates. In combination with the long-sheath technique, adequate control of stent deployment is guaranteed during the entire intervention. The low profile of the device facilitates the use of small sheaths (5 F) to minimize access-site complications.

  12. Choice of wood poles can reduce greenhouse gases

    Energy Technology Data Exchange (ETDEWEB)

    Sedjo, R. A.

    2002-07-01

    The first, second and third assessment reports on climate change of the Intergovernmental Panel on Climate Change (IPCC) are reviewed in an effort to highlight results of past studies on the total life cycle energy utilization of wood products compared with the use of substitute materials such as steel, concrete, bricks and aluminum. Without exception, all studies found that the total energy requirements associated with wood materials are substantially lower than those of other commonly substituted materials. For example, it has been clearly demonstrated that wooden poles are more environmentally benign than concrete or steel poles with regard to their energy utilization and their potential to contribute to atmospheric carbon dioxide emissions. An estimate to convert wood poles to steel poles showed that while the greenhouse gas emissions associated with pole conversion were modest compared to the national total, they were nevertheless a significant percentage of US annual emission (approximately 2.8 per cent of annual US total of 5.28 billion tons of carbon dioxide). These studies provide empirical confirmation of the concept that substitution of high energy-intensive materials for low-energy-using wood materials contributes substantially to the overall increase of carbon dioxide emissions through their overall higher energy requirements.

  13. Analysis of car’s frontal collision against pole

    Science.gov (United States)

    Ispas, N.; Nastasoiu, M.

    2017-10-01

    Reducing the effects of traffic accidents over the occupants is a major objective of collision attempts. Impacts between the car and the pole are very dangerous for the physical integrity of the car’s occupants. To minimalize the effects of such events on the passengers of a vehicle, a whole series of efforts by both designers and experienced engineers led to increasingly the vehicles safety. The main aim of these paper is to quantify the influences over the car passengers of loads involved by car against pole collisions using the same car model at different speeds. Also, this kind on occupant influences were study using a small car model. Other goal of the paper was the study of the cars stiffness in frontal collision against the pole. The paper’s experimental results were obtained by support of DSD, Dr. Steffan Datentechnik GmbH - Linz, Austria. The described tests were performed in full test facility of DSD Linz, in “Easter 2016 PC-Crash Seminar”. Cars accelerations, velocities, rotations angles after pole impact were registered and discussed. The novelty of the paper consists in studies referred for the same car model involved in car against pole collisions at different impact speeds. Paper’s conclusions can be future used for car safety improvement.

  14. The Pole Orientation, Pole Precession, and Moment of Inertia Factor of Saturn

    Science.gov (United States)

    Jacobson, R. A.; French, R. G.; Nicholson, P. D.; Hedman, M.; Colwell, J. E.; Marouf, E.; Rappaport, N.; McGhee, C.; Sepersky, T.; Lonergan, K.

    2011-01-01

    This paper discusses our determination of the Saturn's pole orientation and precession using a combination of Earthbased and spacecraft based observational data. From our model of the polar motion and the observed precession rate we obtain a value for Saturn's polar moment of inertia

  15. Performance of claw-poled PM-stepping motor

    International Nuclear Information System (INIS)

    Liu, C.P.; Jeng, G.R.; Chen, W.C.; Tsai, M.C.; Wu, K.T.; Yao, Y.D.

    2007-01-01

    Present work is to analyze the performance of a permanent-magnetic (PM) stepping motor with claw poles by using the magnetic-circuit simulation technique. In this paper, we calculate the torque characteristics of the motor, such as the detent and the holding torques, and the step-position error by changing the gap between the upper and the lower stators and the staggered angle between the two stators. Through comparison of numerical data with experiment measurements, we found that the detent torque could be effectively reduced by increasing the stator-to-stator gap and further by decreasing the step-position error. Furthermore, the holding torque could be unchanged as the stator assemblage changed; however, it would be degenerated under the condition of low magnetization

  16. South Pole Region of the Moon as Seen by Clementine

    Science.gov (United States)

    1994-01-01

    Lunar mosaic of 1500 Clementine images of the south polar region of the moon. The projection is orthographic, centered on the south pole. The Schrodinger Basin (320 km in diameter) is located in the lower right of the mosaic. Amundsen-Ganswindt is the more subdued circular basin between Schrodinger and the pole. The polar regions of the moon are of special interest because of the postulated occurrence of ice in permanently shadowed areas. The south pole is of greater interest because the area that remains in shadow is much larger than that at the north pole.

  17. Time domain oscillating poles: Stability redefined in Memristor based Wien-oscillators

    KAUST Repository

    Talukdar, Abdul Hafiz Ibne; Radwan, Ahmed G.; Salama, Khaled N.

    2012-01-01

    poles. The idea is verified using a Memristor based Wien oscillator. Sustained oscillations are observed without having the poles of the system fixed on the imaginary axis and the oscillating behavior of the system poles is reported. The oscillating

  18. Product Placement in Cartoons

    Directory of Open Access Journals (Sweden)

    Irena Oroz Štancl

    2014-06-01

    Full Text Available Product placement is a marketing approach for integrating products or services into selected media content. Studies have shown that the impact of advertising on children and youth are large, and that it can affect their preferences and attitudes. The aim of this article is to determine the existing level of product placement in cartoons that are broadcast on Croatian television stations. Content analysis of cartoons in a period of one month gave the following results: in 30% of cartoons product placement was found; most product placement were visual ads, in 89%, however, auditory product placement and plot connection was also found. Most ads were related to toys and it is significant that even 65% of cartoons are accompanied by a large amount of products available on the Croatian market. This is the result of two sales strategies: brand licensing (selling popular cartoon characters to toys, food or clothing companies and cartoon production based on existing line of toys with the sole aim of making their sales more effective.

  19. Boat boarding ladder placement

    Science.gov (United States)

    1998-04-01

    Presented in three volumes; 'Boat Boarding Ladder Placement,' which explores safety considerations including potential for human contact with a rotating propeller; 'Boat Handhold Placement,' which explores essential principles and methods of fall con...

  20. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  1. Modified Miniplates for Temporary Skeletal Anchorage in Orthodontics: Placement and Removal Surgeries

    Science.gov (United States)

    Cornelis, Marie A.; Scheffler, Nicole R.; Mahy, Pierre; Siciliano, Sergio; De Clerck, Hugo J.; Tulloch, J.F. Camilla

    2009-01-01

    Purpose Skeletal anchorage systems are increasingly used in orthodontics. This article describes the techniques of placement and removal of modified surgical miniplates used for temporary orthodontic anchorage and reports surgeons’ perceptions of their use. Patients and Methods We enrolled 97 consecutive orthodontic patients having miniplates placed as an adjunct to treatment. A total of 200 miniplates were placed by 9 oral surgeons. Patients and surgeons completed questionnaires after placement and removal surgeries. Results Fifteen miniplates needed to be removed prematurely. Antibiotics and anti-inflammatories were generally prescribed after placement but not after removal surgery. Most surgeries were performed with the patient under local anesthesia. Placement surgery lasted on average between 15 and 30 minutes per plate and was considered by the surgeons to be very easy to moderately easy. The surgery to remove the miniplates was considered easier and took less time. The patients’ chief complaint was swelling, lasting on average 5.3 ± 2.8 days after placement and 4.5 ± 2.6 days after removal. Conclusions Although miniplate placement/removal surgery requires the elevation of a flap, this was considered an easy and relatively short surgical procedure that can typically be performed with the patient under local anesthesia without complications, and it may be considered a safe and effective adjunct for orthodontic treatment. PMID:18571028

  2. Pole solutions for flame front propagation

    CERN Document Server

    Kupervasser, Oleg

    2015-01-01

    This book deals with solving mathematically the unsteady flame propagation equations. New original mathematical methods for solving complex non-linear equations and investigating their properties are presented. Pole solutions for flame front propagation are developed. Premixed flames and filtration combustion have remarkable properties: the complex nonlinear integro-differential equations for these problems have exact analytical solutions described by the motion of poles in a complex plane. Instead of complex equations, a finite set of ordinary differential equations is applied. These solutions help to investigate analytically and numerically properties of the flame front propagation equations.

  3. On pole structure assignment in linear systems

    Czech Academy of Sciences Publication Activity Database

    Loiseau, J.-J.; Zagalak, Petr

    2009-01-01

    Roč. 82, č. 7 (2009), s. 1179-1192 ISSN 0020-7179 R&D Projects: GA ČR(CZ) GA102/07/1596 Institutional research plan: CEZ:AV0Z10750506 Keywords : linear systems * linear state feedback * pole structure assignment Subject RIV: BC - Control Systems Theory Impact factor: 1.124, year: 2009 http://library.utia.cas.cz/separaty/2009/AS/zagalak-on pole structure assignment in linear systems.pdf

  4. Management of lower pole renal stones: the devil is in the details.

    Science.gov (United States)

    Resorlu, Berkan; Issi, Yasar; Onem, Kadir; Germiyanoglu, Cankon

    2016-03-01

    Shock wave lithotripsy (SWL), retrograde intrarenal surgery (RIRS) and minimally invasive percutaneous nephrolithotomy (MIP) are highly effective treatment options for lower pole stones up to 2 cm. Selecting the best treatment modality represents a controversial area in urology, because each treatment methods have their own advantages and disadvantages. Donaldson and co-workers have recently published a very comprehensive review and meta-analysis to compare the benefits and harms of SWL, RIRS and PNL techniques.

  5. Effect of Dangling Bonds on De-Poling Time for Polymeric Electric Field Optical Sensors

    Directory of Open Access Journals (Sweden)

    Amir R. Ali

    2018-01-01

    Full Text Available This paper investigates the possible chemical changes in polydimethylsiloxane (PDMS caused by two different techniques of fabrication for ultra-sensitive electric field optical sensors. The sensing element is a micro-sphere made from 60:1 PDMS (60 parts base silicon elastomer to one part polymer curing agent by volume. The measurement principle is based on the morphology dependent resonances (MDR shifts of the micro-sphere. We present the effects of curing and poling of polymer micro-spheres used as optical sensors. The degree of curing leads to changes in the de-poling time which results from dangling bonds in the polymeric chains. Consequently, the longevity of the sensitivity of the sensor can extended by two orders of magnitude. An analysis is carried out along with preliminary experiments to investigate that behavior.

  6. Solution of magnetic field and eddy current problem induced by rotating magnetic poles (abstract)

    Science.gov (United States)

    Liu, Z. J.; Low, T. S.

    1996-04-01

    The magnetic field and eddy current problems induced by rotating permanent magnet poles occur in electromagnetic dampers, magnetic couplings, and many other devices. Whereas numerical techniques, for example, finite element methods can be exploited to study various features of these problems, such as heat generation and drag torque development, etc., the analytical solution is always of interest to the designers since it helps them to gain the insight into the interdependence of the parameters involved and provides an efficient tool for designing. Some of the previous work showed that the solution of the eddy current problem due to the linearly moving magnet poles can give satisfactory approximation for the eddy current problem due to rotating fields. However, in many practical cases, especially when the number of magnet poles is small, there is significant effect of flux focusing due to the geometry. The above approximation can therefore lead to marked errors in the theoretical predictions of the device performance. Bernot et al. recently described an analytical solution in a polar coordinate system where the radial field is excited by a time-varying source. A discussion of an analytical solution of the magnetic field and eddy current problems induced by moving magnet poles in radial field machines will be given in this article. The theoretical predictions obtained from this method is compared with the results obtained from finite element calculations. The validity of the method is also checked by the comparison of the theoretical predictions and the measurements from a test machine. It is shown that the introduced solution leads to a significant improvement in the air gap field prediction as compared with the results obtained from the analytical solution that models the eddy current problems induced by linearly moving magnet poles.

  7. Bone graft in the treatment of nonunion of the scaphoid with necrosis of the proximal pole: a literature review.

    Science.gov (United States)

    Severo, Antônio Lourenço; Lemos, Marcelo Barreto; Lech, Osvandré Luiz Canfield; Barreto Filho, Danilo; Strack, Daniel Paulo; Candido, Larissa Knapp

    2017-01-01

    Scaphoid fractures are the most common fractures of the carpal bones, corresponding to 60%. Of these, 10% progress to nonunion; moreover, 3% can present necrosis of the proximal pole. There are various methods of treatment using vascularized and non-vascularized bone grafts. To evaluate and compare the rate of scaphoid consolidation with necrosis of the proximal pole using different surgical techniques. The authors conducted a review of the literature using the following databases: PubMed and BIREME/LILACS, where 13 case series were selected (ten with use of vascularized bone grafts and three of non-vascularized bone grafts), according to inclusion and exclusion criteria. In most cases VBGs were used, especially those based on the 1,2 intercompartmental supraretinacular artery, due to greater reproducibility in performing the surgical technique.

  8. Product placement and its aplication in foreign film

    OpenAIRE

    Vaněk, Tomáš

    2010-01-01

    Marketing and commertial communication and position of product placement within it, legislature governing product placement and its aplication, history of product placement, forms of product placement, use of product placement within marketing campaign, aplication of product placement in movie Casino Royale.

  9. Ridge expansion and immediate placement with piezosurgery and screw expanders in atrophic maxillary sites: two case reports.

    Science.gov (United States)

    Kelly, Andrew; Flanagan, Dennis

    2013-02-01

    Endosseous dental implants may require bone augmentation before implant placement. Herein is described an approach to edentulous ridge expansion with the use of piezosurgery and immediate placement of implants. This may allow for a shortened treatment time and the elimination of donor-site morbidity. Two cases are reported. This technique uses a piezoelectric device to cut the crestal and proximal facial cortices. Space is then created with motorized osteotomes to widen the split ridge. This technique allows for expansion of narrow, anatomically limiting, atrophic ridges, creating space for immediate implant placement. The facial and lingual cortices provide support with vital osteocytes for osteogenesis. The 2 patients presented had adequate bone height for implant placement but narrow edentulous ridges. In patient 1 at site #11, the ridge crest was 3.12 mm thick and was expanded to accept a 4.3 mm × 13 mm implant. The resulting ridge width was 8.88 mm, which was verified using cone beam computerized tomography (CBCT). In patient 2 at site #8 and site #9, the narrow ridge was expanded using the same technique to accept 2 adjacent 3.5 mm × 14 mm implants. The implants were restored to a functional and esthetic outcome.

  10. Laparoscopic upper pole heminephroureterectomy in children: Seven-year experience

    Directory of Open Access Journals (Sweden)

    Antonio Marte

    2015-01-01

    Full Text Available Background: Minimally invasive surgery is the current approach to perform heminephroureterectomy (HN in children. This can be obtained through a transperitoneal (TP or a retroperitoneal approach. Here, we report our experience using a TP approach. Materials and Methods: From 2005 to 2014, 22 TP laparoscopic upper poles HN were performed at our institution. There were nine girls and 13 boys aged between 20 months and 6 years (mean age 3.9. Eight patients were diagnosed prenatally, 17 patients presented with urinary tract infection (UTI and three with vomiting and failure to thrive. The indication for HN was reflux nephropathy and UTI in non-functioning upper pole in 19 patients and cystic dysplasia in 1 patient. The surgical technique involved the following steps: Cystoscopic recognition; positioning of 3-4 trocar (right HN; identification of the kidney (detachment of the colon; isolation and low ligation of the dilated ureter; decrossing from renal vessels; section of the parenchyma by LigaSure; haemostasis with clips and LigaSure; drain. Results: The mean operative time was 154 min (range: 81-220 min. All patients were discharged from the 2 nd to 4 th day. Neither major complication nor conversion was recorded. 1 patient presented leakage of urine for 7 days from the drainage which resolved spontaneously. At ultrasound follow-up, 5 patients showed a secondary perirenal cyst, 2-5 cm diameter that resolved spontaneously. Conclusion: The results indicate that laparoscopic upper pole heminephrectomy is the treatment of choice in cases of non-functioning dilated lower segments of duplicated kidneys. The use of laparoscopic approach offers a good working space, a good visual control of the vessels and allows a very low isolation of the ureteral stump which counterbalance the peritoneal violation.

  11. Measurement and calculation of cosmic radiation exposure during a pole-to-pole flight sequence

    International Nuclear Information System (INIS)

    Taylor, Graeme C.; Ojjeh, Captain Aziz

    2010-01-01

    Cosmic ray dosimetry measurements were carried out on board a Global Express business jet operated by TAG Aviation (UK) during a pole-to-pole flight sequence that took place in November 2008. One Hawk TEPC and two EPDN2s were flown, and the TEPC measurements compared to calculated values from the route dose codes AVIDOS, CARI 6M, EPCARD versions 3.2 and 3.34, QARM and SIEVERT (online version). The largest difference between measured and calculated doses for the total flight sequence was found to be 13%. Agreement between the readings of the TEPC and the EPDN2s (once a calibration factor from the CERN High Energy Reference Field had been applied) was reasonably good given the relatively large uncertainties associated with the EPDN2 measurements.

  12. 22 CFR 96.50 - Placement and post-placement monitoring until final adoption in incoming cases.

    Science.gov (United States)

    2010-04-01

    ... qualified escorts, if used, and, if possible, in the company of the prospective adoptive parent(s). (b) In... greater. (c) When a placement for adoption is in crisis in the post-placement phase, the agency or person... resolving the crisis and the placement is disrupted, the agency or person assuming custody of the child...

  13. A format for phylogenetic placements.

    Directory of Open Access Journals (Sweden)

    Frederick A Matsen

    Full Text Available We have developed a unified format for phylogenetic placements, that is, mappings of environmental sequence data (e.g., short reads into a phylogenetic tree. We are motivated to do so by the growing number of tools for computing and post-processing phylogenetic placements, and the lack of an established standard for storing them. The format is lightweight, versatile, extensible, and is based on the JSON format, which can be parsed by most modern programming languages. Our format is already implemented in several tools for computing and post-processing parsimony- and likelihood-based phylogenetic placements and has worked well in practice. We believe that establishing a standard format for analyzing read placements at this early stage will lead to a more efficient development of powerful and portable post-analysis tools for the growing applications of phylogenetic placement.

  14. Immediate Implant Placement of a Single Central Incisor Using a CAD/CAM Crown-Root Form Technique: Provisional to Final Restoration.

    Science.gov (United States)

    Vafiadis, Dean; Goldstein, Gary; Garber, David; Lambrakos, Anthony; Kowalski, Bj

    2017-02-01

    Preserving soft and hard tissues after extraction and implant placement is crucial for anterior esthetics. This technique will show how the information gathered from a cone-beam computed tomography (CBCT) scan of the maxillary left central incisor and an intra-oral digital impression can be merged to fabricate a CAD/CAM crown-root matrix to be used as an immediate provisional restoration that mimics the natural anatomy. Due to trauma, a left central incisor appeared to be fractured and was scheduled for extraction and implant placement. The crown-root configuration captured by the CBCT scan was merged with the digital files from an intra-oral digital impression. A CAD/CAM crown-root matrix was fabricated. Because the matrix shell was fabricated with the exact anatomy of the natural tooth, it replicated the position and three dimensional anatomy of the soft and hard tissue. It was connected to the implant with a customized provisional abutment. A digital impression of a coded healing abutment was made to fabricate the final implant abutment and final restoration. Throughout the treatment time and 36 months after completion, the thickness of tissue, emergence profile, and adjacent papilla was analyzed by clinical evaluation and photography and seemed to be maintained. The use of a pre-operative intra-oral digital scan of the clinical crown-root architecture and the CBCT scan of the bone/root anatomy, can be used together to fabricate a CAD/CAM crown-root form provisional matrix. This digital design helps in the preservation of the 3D tissue topography, as well as the final restoration. The preservation of soft and hard tissue after extraction and implant placement has always been paramount for ideal anterior implant esthetics. Using the information from digital files from CBCT scans and intra-oral scans may help the clinician identify critical anatomical features that can be replicated in the provisional and final CAD/CAM restoration. (J Esthet Restor Dent 29

  15. A discussion on leading renormalon in the pole mass

    Science.gov (United States)

    Komijani, J.

    2017-08-01

    Perturbative series of some quantities in quantum field theories, such as the pole mass of a quark, suffer from a kind of divergence called renormalon divergence. In this paper, the leading renormalon in the pole mass is investigated, and a map is introduced to suppress this renormalon. The inverse of the map is then used to generate the leading renormalon and obtain an expression to calculate its overall normalization. Finally, the overall normalization of the leading renormalon of the pole mass is calculated for several values of quark flavors.

  16. Zygomatic bone graft for oral-antral communication closure and implant placement.

    Science.gov (United States)

    Peñarrocha-Diago, Miguel; García, Berta; Gomez, Dolores; Balaguer, José

    2007-01-01

    The roots of molar and premolar maxillary teeth are often very close to the floor of the maxillary sinus. As a result, extraction of these teeth can leave an oral-antral communication or lead to a fistula that requires treatment. A woman with an oral-antral communication secondary to extraction of a maxillary molar is presented. The communication was closed by means of a bone graft harvested from the wall of the sinus (zygomatic bone). After 3 months, 2 dental implants were placed, one in the pterygoid area and the other with parasinusal angulation. Rehabilitation followed in the form of a screw-retained, fixed prosthesis 3 months after implant placement. There have been no complications after 1 year of follow-up. This surgical technique allowed closure of an oral-antral communication produced by molar extraction through placement of a zygomatic bone graft and subsequent placement of 2 dental implants.

  17. Physics on the Z-pole

    International Nuclear Information System (INIS)

    Omori, Tsunehiko; Kurihara, Yoshimasa; Sugimoto, Yasuhiro; Fujii, Yoshiaki; Fujii, Keisuke

    1994-01-01

    JLC will provide a high luminosity of 2.0 x 10 33 cm -2 s -1 on the Z-pole. To realize the Z-pole running we need to add a transport line to bypass unnecessary part of the main linac. With this high luminosity, the third angle of the unitality triangle (sin 2φ 3 ) can be measured in B s (B s ) → pK s channel with 3σ sensitivity in 1 year when sin 2φ 3 = -0.5, Xs = 10, and the branching ratio of the channel is 2 x 10 -5 . Also sin 2 θw can be measured with accuracy of Δsin 2 θw/sin 2 θw = 0.1%. (J.P.N.)

  18. Inspection of steel poles; ultrasonic testing of anchor ground rods and cathodic reactions : Corrosion detection : an emerging problem in buried steel structures

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, A.K.; Randle, R.E.; Stewart, A.H. [EDM International Inc., Fort Collins, CO (United States)

    2002-07-01

    A typical inspection of steel utility poles routinely overlooks what is below ground, such as anchor rods, stub angles in lattice towers, and direct embedded steel poles. Stub angles are lap or butt spliced to the tower leg and extend several feet below ground line. A case study concerning stub angles (Oberst 1998) is discussed. An inspection of steel poles erected in 1929 revealed that 40 per cent of legs had complete loss of galvanizing, 10 per cent of legs had greater than 10 per cent loss of cross-section, and 2 per cent of legs had greater than 80 per cent loss of cross-section. All corrosion was found within one foot of ground line. A relatively new concept is direct embedded steel poles. An emerging problem concerns tree induced anchor rod corrosion. A corrosion technique for anchor rods was developed and has been commercially available for the past three years. Its effectiveness was verified at the Montana Power Company 500 kV Colstrip Project, where 3 anchor failures were detected in 1995 due to corrosion wastage. The rods are classified as being in good condition up to 10 per cent loss of cross-section, moderate corrosion for losses between 10 and 25 per cent, and excessive corrosion for losses greater than 25 per cent. The results obtained at the Montana Power Company indicated the technique was 98 per cent accurate. The authors discuss the capabilities and limitations of the technique. It was also applied for the Anchor Rod Inspection Project of the Georgia Power Company (GPC). The technique is evaluated in the laboratory, then optimized. Field prototypes are developed, followed by an evaluation at different test sites. figs.

  19. Poles of the S matrix for a complex potential

    International Nuclear Information System (INIS)

    Dabrowski, J.

    1996-01-01

    Trajectories of S matrix poles in complex k plane are presented for a complex square well potential. A simple rule is given for predicting the effect of an absorptive potential on the location of these poles. copyright 1996 The American Physical Society

  20. ESL Placement and Schools

    Science.gov (United States)

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra; Frisco, Michelle

    2010-01-01

    In this study, the authors explore English as a Second Language (ESL) placement as a measure of how schools label and process immigrant students. Using propensity score matching and data from the Adolescent Health and Academic Achievement Study and the National Longitudinal Study of Adolescent Health, the authors estimate the effect of ESL placement on immigrant achievement. In schools with more immigrant students, the authors find that ESL placement results in higher levels of academic performance; in schools with few immigrant students, the effect reverses. This is not to suggest a one-size-fits-all policy; many immigrant students, regardless of school composition, generational status, or ESL placement, struggle to achieve at levels sufficient for acceptance to a 4-year university. This study offers several factors to be taken into consideration as schools develop policies and practices to provide immigrant students opportunities to learn. PMID:20617111

  1. Institutional Evaluation in Poles of the Open University System of Brazil

    Directory of Open Access Journals (Sweden)

    Alexciano de Sousa Martins

    2018-03-01

    Full Text Available The study wanted to know the institutional evaluation in poles of distance education, of the Open University of Brazil (UAB system, analyzing the poles of the State of Ceará. The UAB system of the Brazilian Ministry of Education makes it possible to offer courses of higher level agreements with public universities. Ceará counts on UAB poles, since 2006, that form teachers and other professionals, even in regions lacking public higher education. The objective of this study was to discuss the importance of the institutional evaluation in the poles of the Open University of Brazil program through an exploratory and descriptive field research, showing that the institutional evaluation at the poles is minimal and out of line with the legislation in force. Suggestions on how to develop the evaluative practice.

  2. Structural behaviour of concrete poles used in electric's power distribution network

    Directory of Open Access Journals (Sweden)

    Mehran Zeynalian

    2017-12-01

    Full Text Available Based on a preliminary study on regional electric companies, it is shown that there is no precise structural design on the concrete poles. This leads to uneconomical and overestimated networks’ components. Therefore, this study was aimed to investigate the lateral performance of the concrete poles which are employed in electric’s power distribution network. This paper presents a numerical study on structural performance of 12 m concrete poles used in electric’s power distribution network using Abaqus software. A sensitivity study for mesh size is carried out and concrete damaged plasticity has been employed. The results show that relatively coarse mesh (average in damaged concrete method gives more reliable result. Some experimental tests based on the Iranian standards were performed in order to make a bench mark for numerical output. Comparison between numerical and experimental results indicates a good agreement between the results. The outcomes also suggest that while the applied lateral load is less than around 400 kg which is assumed as the nominal resistance of the pole, no transverse crack occurs. Based on both experimental and numerical results, one or two transverse cracks are reported when the applied force reaches up to 600 kg. The rate of cracks is amplified by increasing the applied force; and finally, the pole would lose its capacity when the load rises much more than 1200 kg. The study also shows that the poles are very weak when the load direction changes. Also, it can be concluded that the final strength of the pole is higher than what the standards recommend. Finally, seismic behavior factor of the poles around both main axes are evaluated. The estimated seismic resistance factor for the concrete poles indicates that the prescribed R factor for such structure is relatively low; and can be improved at least 20%.

  3. 20 CFR 670.730 - What are the responsibilities of placement agencies?

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false What are the responsibilities of placement agencies? 670.730 Section 670.730 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF... techniques and job search strategies; (3) Identifying job leads or educational and training opportunities...

  4. Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure.

    Science.gov (United States)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu

    2018-05-01

    To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.

  5. Stone-free-rate after extracorporeal shockwave lithotripsy in the management of pediatric renal stones in lower pole and other locations - a comparative study

    International Nuclear Information System (INIS)

    Iqbal, N.; Muhammad, S.; Akhter, S.

    2016-01-01

    To determine a difference in the stone-free-rate among different renal locations in children after extracorporeal shockwave lithotripsy (ESWL). Study Design: A descriptive study. Place and Duration of Study: Urology Department, Shifa International Hospital, Islamabad, Pakistan, from January 2007 to June 2015. Methodology: The study included children who underwent ESWL, divided into three groups based on location of stones in kidney as group A (lower pole stones), group B (upper and mid pole stones) and group C (renal pelvis stone), respectively. ESWL was done by standard technique using Storz Modulith SLX lithotripter 3rd generation. Data was collected by chart review. SPSS version 16 was used for data analysis. Results: Among 76 children with mean age of 7.55 +-4.16 years, 55 (72.4%) were males whereas 21 (27.6%) were females. Mean stone size was 1.08 +-0.59 cm. There were 34, 17 and 25 cases in groups A, B and C, respectively. PostESWL stone-free-rate was 47% in lower pole stones, 70.58% in upper and mid pole stones, and 68% in renal pelvis stones. Hematuria was seen in one patient from each group, sepsis in two patients from each of the mid pole/upper pole and lower pole group, while Steinstrasse in one patient from each group. (author)

  6. The self-consistent dynamic pole tide in global oceans

    Science.gov (United States)

    Dickman, S. R.

    1985-01-01

    The dynamic pole tide is characterized in a self-consistent manner by means of introducing a single nondifferential matrix equation compatible with the Liouville equation, modelling the ocean as global and of uniform depth. The deviations of the theory from the realistic ocean, associated with the nonglobality of the latter, are also given consideration, with an inference that in realistic oceans long-period modes of resonances would be increasingly likely to exist. The analysis of the nature of the pole tide and its effects on the Chandler wobble indicate that departures of the pole tide from the equilibrium may indeed be minimal.

  7. A comparison C1-C2 transarticular screw placement after self-education and mentored education of orthopaedic residents.

    Science.gov (United States)

    Kirkpatrick, John S

    2012-08-01

    Prospective randomized trial. This study will provide preliminary data on whether residents can be "self-taught" and to what extent a lecture, demonstration, and coaching can improve skills and knowledge. Practice-based learning is an essential competency in Accreditation Council for graduate Medical Education-accredited residencies. Little has been done to demonstrate whether residents can be self-taught or benefit from mentoring in understanding and performing difficult surgical tasks. A written test was given to orthopedic residents on C1-C2 transarticular screw placement. They were then provided reading on C1-C2 transarticular screw placement. Residents were then divided into a "self-directed learning" group and a "mentored learning" group. All residents then performed the technique on models, with the "mentored" group receiving a lecture and coaching from the mentor. The models were analyzed for technique errors and the previous test was administered again as a posttest. The test and screw placement were repeated 4 months later. Residents without mentoring had an average improvement of 4.5 points, those with mentoring had average improvement of 8.6 points (P=0.0068). The screw placement technique error rate for the nonmentored group (n=8) was 2.55, and for the mentored group (n=9) was 1.47 (P=0.004). Sixteen residents completed the delayed test, 7 from the nonmentored groups and 8 from the mentored group. Nine residents were able to repeat the screw placement technique 4 months after the initial test and screw placement, 3 nonentored, and 6 mentored. Although there were some trends toward the mentored group having better retention, neither knowledge nor skill was statistically different. This preliminary trial seems to indicate that residents provided a lecture and guided technical instruction will obtain knowledge and perform procedures better than those that do not. Conclusions based upon Post Graduate year, motivation, and interest in spine surgery could

  8. A virtual reality based simulator for learning nasogastric tube placement.

    Science.gov (United States)

    Choi, Kup-Sze; He, Xuejian; Chiang, Vico Chung-Lim; Deng, Zhaohong

    2015-02-01

    Nasogastric tube (NGT) placement is a common clinical procedure where a plastic tube is inserted into the stomach through the nostril for feeding or drainage. However, the placement is a blind process in which the tube may be mistakenly inserted into other locations, leading to unexpected complications or fatal incidents. The placement techniques are conventionally acquired by practising on unrealistic rubber mannequins or on humans. In this paper, a virtual reality based training simulation system is proposed to facilitate the training of NGT placement. It focuses on the simulation of tube insertion and the rendering of the feedback forces with a haptic device. A hybrid force model is developed to compute the forces analytically or numerically under different conditions, including the situations when the patient is swallowing or when the tube is buckled at the nostril. To ensure real-time interactive simulations, an offline simulation approach is adopted to obtain the relationship between the insertion depth and insertion force using a non-linear finite element method. The offline dataset is then used to generate real-time feedback forces by interpolation. The virtual training process is logged quantitatively with metrics that can be used for assessing objective performance and tracking progress. The system has been evaluated by nursing professionals. They found that the haptic feeling produced by the simulated forces is similar to their experience during real NGT insertion. The proposed system provides a new educational tool to enhance conventional training in NGT placement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Dual kidney transplant techniques: A systematic review.

    Science.gov (United States)

    Cocco, Annelise; Shahrestani, Sara; Cocco, Nicholas; Hameed, Ahmer; Yuen, Lawrence; Ryan, Brendan; Hawthorne, Wayne; Lam, Vincent; Pleass, Henry

    2017-08-01

    Dual kidney transplantation (DKT) was developed to improve outcomes from transplantation of extended criteria donors (ECD). This study examined which surgical techniques have been reported for DKT and whether any technique had superior patient and graft survival. Electronic databases were searched for published studies mapping to MESH terms: "kidney or renal" AND "transplan*" AND "dual or double." Single case reports, studies of patients less than 18 years old, studies which did not describe the surgical technique, and studies that did not report patient or graft survival were excluded. Fifteen reports of 434 DKT recipients were identified. Three techniques were described: bilateral placement; unilateral placement with separate anastomoses; and unilateral placement with patch anastomoses. Patient survival across all three techniques was over 95% at 1 year, and graft survival was also similar at over 90%. Rates of delayed graft function were between 20% and 30% across all techniques. The three techniques have equivalent delayed graft function as well as patient and graft survival rates. This is an encouraging result as it means that the surgeon can choose to use the technique which is most appropriate for their own skills and for the patient. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. A variable-mode stator consequent pole memory machine

    Science.gov (United States)

    Yang, Hui; Lyu, Shukang; Lin, Heyun; Zhu, Z. Q.

    2018-05-01

    In this paper, a variable-mode concept is proposed for the speed range extension of a stator-consequent-pole memory machine (SCPMM). An integrated permanent magnet (PM) and electrically excited control scheme is utilized to simplify the flux-weakening control instead of relatively complicated continuous PM magnetization control. Due to the nature of memory machine, the magnetization state of low coercive force (LCF) magnets can be easily changed by applying either a positive or negative current pulse. Therefore, the number of PM poles may be changed to satisfy the specific performance requirement under different speed ranges, i.e. the machine with all PM poles can offer high torque output while that with half PM poles provides wide constant power range. In addition, the SCPMM with non-magnetized PMs can be considered as a dual-three phase electrically excited reluctance machine, which can be fed by an open-winding based dual inverters that provide direct current (DC) bias excitation to further extend the speed range. The effectiveness of the proposed variable-mode operation for extending its operating region and improving the system reliability is verified by both finite element analysis (FEA) and experiments.

  11. Second harmonic generation from corona-poled polymer thin films ...

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... We characterize thermal stability of second harmonic generation (SHG) properties of four different Y-type polymers poled using corona poling method. These polymers are based on donor–acceptor–donor-type repeating unit with different aromatic moieties acting as donors and dicyanomethylene acting as ...

  12. SFG synthesis of general high-order all-pass and all-pole current transfer functions using CFTAs.

    Science.gov (United States)

    Tangsrirat, Worapong

    2014-01-01

    An approach of using the signal flow graph (SFG) technique to synthesize general high-order all-pass and all-pole current transfer functions with current follower transconductance amplifiers (CFTAs) and grounded capacitors has been presented. For general nth-order systems, the realized all-pass structure contains at most n + 1 CFTAs and n grounded capacitors, while the all-pole lowpass circuit requires only n CFTAs and n grounded capacitors. The resulting circuits obtained from the synthesis procedure are resistor-less structures and especially suitable for integration. They also exhibit low-input and high-output impedances and also convenient electronic controllability through the g m-value of the CFTA. Simulation results using real transistor model parameters ALA400 are also included to confirm the theory.

  13. SFG Synthesis of General High-Order All-Pass and All-Pole Current Transfer Functions Using CFTAs

    Directory of Open Access Journals (Sweden)

    Worapong Tangsrirat

    2014-01-01

    Full Text Available An approach of using the signal flow graph (SFG technique to synthesize general high-order all-pass and all-pole current transfer functions with current follower transconductance amplifiers (CFTAs and grounded capacitors has been presented. For general nth-order systems, the realized all-pass structure contains at most n + 1 CFTAs and n grounded capacitors, while the all-pole lowpass circuit requires only n CFTAs and n grounded capacitors. The resulting circuits obtained from the synthesis procedure are resistor-less structures and especially suitable for integration. They also exhibit low-input and high-output impedances and also convenient electronic controllability through the gm-value of the CFTA. Simulation results using real transistor model parameters ALA400 are also included to confirm the theory.

  14. Soft rot decay capabilities and interactions of fungi and bacteria from fumigated utility poles

    International Nuclear Information System (INIS)

    Wang, C.J.K.; Worrall, J.J.

    1992-11-01

    The objectives were to (1) identify microfungi and bacterial associates isolated from fumigated southern pine poles from EPRI project RP 1471-72, (2) study the soft-rot capabilities of predominant fungi, and (3) study interactions among microorganisms in relation to wood decay. Methods for identification followed standard techniques using morphological and physiological criteria. Soft-rot by microfungi alone and with bacteria was determined as weight loss and anatomical examination of wood blocks using light microscopy and limited electron microscopy. Acinetobacter calcoaceticus was the predominant bacterium. Twenty-one species of microfungi were identified including four new species. A book entitled IDENTIFICATION MANUAL FOR FUNGI FROM UTILITY POLES IN THE EASTERN UNITED STATES was published. An improved soft-rot test was devised. Fifty-one of 84 species (60%) of microfungi from poles tested were soft-rot positive; that is much greater than previously reported. Three types of anatomical damage of wood of pine or birch caused by soft-rot fungi were described. Interaction tests showed that, in some cases, there was a strong synergism between bacteria and fungi in causing weight loss, but results were inconsistent. Although soft rot is often most apparent under conditions of very high moisture, intermediate moisture levels appear to be optimal, as with basidiomycete decayers

  15. Nonlinear performance characterization in an eight-pole quasi-elliptic bandpass filter

    International Nuclear Information System (INIS)

    Mateu, J; Collado, C; Menendez, O; O'Callaghan, J M

    2004-01-01

    In this work we predict the nonlinear behaviour of an eight-pole quasi-elliptic bandpass high temperature superconducting (HTS) filter with an equivalent circuit extracted from intermodulation measurements performed at the centre of the filter passband. We present measurements that show that the equivalent circuit is able to predict the intermodulation products produced by the filter when driven by two in-band or out-of-band sinusoidal signals. Numerical techniques based on harmonic balance are used to extract the elements of the equivalent circuit and to simulate its nonlinear performance

  16. The Written-Pole{sup TM} motor: high efficiency - low start current

    Energy Technology Data Exchange (ETDEWEB)

    Beck, B. [C.Eng. Precise Power Corp., Bradenton, FL (United States); Friesen, D. [P.E. Manitoba Hydro, Winnipeg (Canada)

    2000-07-01

    Written-Pole{sup TM} technology is a patented machine technology, which changes the magnetic polarity of the rotor field in a rotating machine, while the machine is operating. The number of poles is thereby changed, resulting in a constant frequency - variable speed machine. When operating as a motor, a Written-Pole machine has inherently low starting current and high operating efficiency. (orig.)

  17. The use of a position sensitive detector or of a multidetector for the measurement of pole figures by neutron time-of-flight technique

    International Nuclear Information System (INIS)

    Walther, K.

    1990-01-01

    The neutron flux of even high flux reactors is weak in comparison with the quantum flux of X-ray tubes and therefore in order to decrease the expense on measuring time more and more neutron diffractometers are equipped with position sensitive detectors or multidetectors. In this paper the peculiarities of the use of such detecting devices are discussed for the measurement of pole figures. A special arrangement of a multidetector is proposed which will allow one to scan the whole pole figure by rotating the sample about only one axis and considerably will save measuring time. 4 refs.; 5 figs

  18. Direct calculation of resonance energies and widths from the poles of the multichannel T matrix

    International Nuclear Information System (INIS)

    Watson, D.K.

    1984-01-01

    A numerical method is developed to search the complex momentum plane for the poles of the multichannel T matrix. No resonance or continuum wave functions are calculated and no complex basis functions are required. The appropriate Green's function is constructed and used to enforce the asymptotic behavior. Results are obtained for a three-state model problem and compared with results from other techniques

  19. Large optical second-order nonlinearity of poled WO3-TeO2 glass.

    Science.gov (United States)

    Tanaka, K; Narazaki, A; Hirao, K

    2000-02-15

    Second-harmonic generation, one of the second-order nonlinear optical properties of thermally and electrically poled WO>(3)-TeO>(2) glasses, has been examined. We poled glass samples with two thicknesses (0.60 and 0.86 mm) at various temperatures to explore the effects of external electric field strength and poling temperature on second-order nonlinearity. The dependence of second-harmonic intensity on the poling temperature is maximum at a specific poling temperature. A second-order nonlinear susceptibility of 2.1 pm/V was attained for the 0.60-mm-thick glass poled at 250 degrees C. This value is fairly large compared with those for poled silica and tellurite glasses reported thus far. We speculate that the large third-order nonlinear susceptibility of WO>(3)- TeO>(2) glasses gives rise to the large second-order nonlinearity by means of a X((2)) = 3X((3)) E(dc) process.

  20. Data-driven sensor placement from coherent fluid structures

    Science.gov (United States)

    Manohar, Krithika; Kaiser, Eurika; Brunton, Bingni W.; Kutz, J. Nathan; Brunton, Steven L.

    2017-11-01

    Optimal sensor placement is a central challenge in the prediction, estimation and control of fluid flows. We reinterpret sensor placement as optimizing discrete samples of coherent fluid structures for full state reconstruction. This permits a drastic reduction in the number of sensors required for faithful reconstruction, since complex fluid interactions can often be described by a small number of coherent structures. Our work optimizes point sensors using the pivoted matrix QR factorization to sample coherent structures directly computed from flow data. We apply this sampling technique in conjunction with various data-driven modal identification methods, including the proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD). In contrast to POD-based sensors, DMD demonstrably enables the optimization of sensors for prediction in systems exhibiting multiple scales of dynamics. Finally, reconstruction accuracy from pivot sensors is shown to be competitive with sensors obtained using traditional computationally prohibitive optimization methods.

  1. Endoscopic ultrasound coil placement of gastric varices: Emerging modality for recurrent bleeding gastric varices

    Directory of Open Access Journals (Sweden)

    Yogesh Harwani

    2014-01-01

    Full Text Available Gastric varices are the probable source of bleeding in 10-36% of patients, with acute variceal bleeding and carry high mortality and rebleeding rates. Till date, cyanoacrylate glue injection is considered as the standard of care but has high complication rate. Endoscopic ultrasound (EUS guided coil placement is a new emerging technique of management of gastric varices. In this case report, we detail the EUS guided coil placement for management of gastric varices after failed glue injections.

  2. Nonlinear observer based phase synchronization of chaotic systems

    International Nuclear Information System (INIS)

    Meng Juan; Wang Xingyuan

    2007-01-01

    This Letter analyzes the phase synchronization problem of autonomous chaotic systems. Based on the nonlinear state observer algorithm and the pole placement technique, a phase synchronization scheme is designed. The phase synchronization of a new chaotic system is achieved by using this observer controller. Numerical simulations further demonstrate the effectiveness of the proposed phase synchronization scheme

  3. Placement by thermodynamic simulated annealing

    International Nuclear Information System (INIS)

    Vicente, Juan de; Lanchares, Juan; Hermida, Roman

    2003-01-01

    Combinatorial optimization problems arise in different fields of science and engineering. There exist some general techniques coping with these problems such as simulated annealing (SA). In spite of SA success, it usually requires costly experimental studies in fine tuning the most suitable annealing schedule. In this Letter, the classical integrated circuit placement problem is faced by Thermodynamic Simulated Annealing (TSA). TSA provides a new annealing schedule derived from thermodynamic laws. Unlike SA, temperature in TSA is free to evolve and its value is continuously updated from the variation of state functions as the internal energy and entropy. Thereby, TSA achieves the high quality results of SA while providing interesting adaptive features

  4. Regge poles and alpha scattering

    International Nuclear Information System (INIS)

    Ceuleneer, R.

    1974-01-01

    The direct Regge pole model as a means of describing resonances in elastic particle scattering has been used for the analysis of the so-called ''anormalous large angle scattering'' of alpha particles by spinless nuclei. (Z.M.)

  5. A serious game for learning ultrasound-guided needle placement skills.

    Science.gov (United States)

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  6. Time domain oscillating poles: Stability redefined in Memristor based Wien-oscillators

    KAUST Repository

    Talukdar, Abdul Hafiz Ibne

    2012-07-28

    Traditionally, the necessary and sufficient condition for any system to be oscillating is that its poles are located on the imaginary (jω) axis. In this paper, for the first time, we have shown that systems can oscillate with time-domain oscillating poles. The idea is verified using a Memristor based Wien oscillator. Sustained oscillations are observed without having the poles of the system fixed on the imaginary axis and the oscillating behavior of the system poles is reported. The oscillating resistance and triangular shape of FFT are also demonstrated with mathematical reasoning and simulation results to support the unusual and surprising characteristics. © 2009 IEEE.

  7. Glass Waveguides for Periodic Poling

    DEFF Research Database (Denmark)

    Fage-Pedersen, Jacob; Jacobsen, Rune Shim; Kristensen, Martin

    2005-01-01

    Planar silica-based waveguide devices have been developed for second-harmonic generation by poling with periodic electrodes. We show that detrimental charge transport can occur along interfaces, but with proper choice of fabrication, high-quality devices are obtained....

  8. Single perineal incision placement of artificial urinary sphincter with cadaveric correlation of sub-dartos pump placement

    Directory of Open Access Journals (Sweden)

    Cooper R. Benson

    Full Text Available ABSTRACT Purpose We present a novel AUS implantation technique using a single perineal incision for single device placement or in combination with an inflatable penile prosthesis (IPP. Urinary and sexual dysfunction following the management of prostate cancer has a significant impact on the quality of life of our patients. While there are marginal changes in the prosthetic devices, we strive to reduce post-operative morbidity while maximizing efficacy. Materials and Methods We retrospectively reviewed the outcomes of 6 patients who underwent single perineal incision placement of a virgin AUS in 2014, 3 with simultaneous IPP placement. In all cases, the pressure regulating balloons (PRB were placed in a high sub-muscular ectopic position and the pumps were placed into a sub-dartos pouch through the perineal incision, which was also validated using a cadaveric model. Results The mean patient age was 61 (SD, 7.5 years with mean body mass index of 31 (SD, 5.9. The average pre-operative pad usage was 7.7 (SD 1.63 pads per day. The mean follow-up was 13.9 months (SD 9.45. Four out of the six patients reported utilizing ≤1 pad daily at follow-up. The one patient who was not initially dry required downsizing of his cuff to 3.5cm; the remaining patient was lost to follow-up. There were no identifiable perioperative or post-operative complications. Conclusions We present our initial report of using a single perineal incision for AUS implantation with a validated sub-dartos pump location, which is safe and effective for implantation of an AUS as a single or double implantation in well-selected patients.

  9. Academic achievement and course taking among language minority youth in U.S. schools: Effects of ESL placement.

    Science.gov (United States)

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra

    2010-03-01

    The 1974 Lau decision requires that U.S. public schools ensure a meaningful education for students learning English. English as a Second Language (ESL) placement is an institutional response to the linguistic needs of these students; however, its academic implications remain largely unexplored. Using nationally representative data from the Educational Longitudinal Study (ELS), the effects of ESL placement on college preparatory course enrollment and academic achievement of language minority students are estimated, first with fixed effects regression models and then with multi-level propensity score matching techniques. While numerous school and individual level factors beyond language proficiency predict ESL placement, a significant negative estimated effect of ESL placement on science enrollment and cumulative GPA is consistently found. Perhaps more important, however, no positive effects of ESL placement on the achievement of language minority youth are found when accounting for English proficiency and other potential covariates.

  10. Humanitarian engineering placements in our own communities

    Science.gov (United States)

    VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.

    2010-05-01

    There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be transformative for both the student and the community, although this potential is not always seen. In order to investigate the role of local placements, qualitative research interviews were conducted. Thirty-two semi-structured research interviews were conducted and analysed, resulting in a distinct outcome space. It is concluded that local humanitarian engineering placements greatly complement international placements and are strongly recommended if international placements are conducted. More importantly it is seen that we are better suited to address the marginalised in our own community, although it is often easier to see the needs of an outside populace.

  11. The Achievements of the GLAMOROUS Project on Poling

    DEFF Research Database (Denmark)

    Margulis, Walter; Myrén, N.; Fage-Pedersen, Jacob

    2005-01-01

    The GLAMOROUS project had as objective to demonstrate the feasibility of fibre and waveguide components with a second order nonlinearity induced by poling. The accomplishments of this nine-partners European Research Project are described.......The GLAMOROUS project had as objective to demonstrate the feasibility of fibre and waveguide components with a second order nonlinearity induced by poling. The accomplishments of this nine-partners European Research Project are described....

  12. Converting point-wise nuclear cross sections to pole representation using regularized vector fitting

    Science.gov (United States)

    Peng, Xingjie; Ducru, Pablo; Liu, Shichang; Forget, Benoit; Liang, Jingang; Smith, Kord

    2018-03-01

    Direct Doppler broadening of nuclear cross sections in Monte Carlo codes has been widely sought for coupled reactor simulations. One recent approach proposed analytical broadening using a pole representation of the commonly used resonance models and the introduction of a local windowing scheme to improve performance (Hwang, 1987; Forget et al., 2014; Josey et al., 2015, 2016). This pole representation has been achieved in the past by converting resonance parameters in the evaluation nuclear data library into poles and residues. However, cross sections of some isotopes are only provided as point-wise data in ENDF/B-VII.1 library. To convert these isotopes to pole representation, a recent approach has been proposed using the relaxed vector fitting (RVF) algorithm (Gustavsen and Semlyen, 1999; Gustavsen, 2006; Liu et al., 2018). This approach however needs to specify ahead of time the number of poles. This article addresses this issue by adding a poles and residues filtering step to the RVF procedure. This regularized VF (ReV-Fit) algorithm is shown to efficiently converge the poles close to the physical ones, eliminating most of the superfluous poles, and thus enabling the conversion of point-wise nuclear cross sections.

  13. Efficacy of the lithotripsy in treating lower pole renal stones.

    Science.gov (United States)

    Cui, Helen; Thomee, Eeke; Noble, Jeremy G; Reynard, John M; Turney, Benjamin W

    2013-06-01

    Use of extracorporeal lithotripsy is declining in North America and many European countries despite international guidelines advocating it as a first-line therapy. Traditionally, lithotripsy is thought to have poor efficacy at treating lower pole renal stones. We evaluated the success rates of lithotripsy for lower pole renal stones in our unit. 50 patients with lower pole kidney stones ≤15 mm treated between 3/5/11 and 19/4/12 were included in the study. Patients received lithotripsy on a fixed-site Storz Modulith SLX F2 lithotripter according to a standard protocol. Clinical success was defined as stone-free status or asymptomatic clinically insignificant residual fragments (CIRFs) ≤3 mm at radiological follow-up. The mean stone size was 7.8 mm. The majority of stones (66 %) were between 5 and 10 mm. 28 % of stones were between 10 and 15 mm. For solitary lower pole stones complete stone clearance was achieved in 63 %. Total stone clearance including those with CIRFs was achieved in 81 % of patients. As expected, for those with multiple lower pole stones the success rates were lower: complete clearance was observed in 39 % and combined clearance including those with CIRFs was 56 %. Overall, complete stone clearance was observed in 54 % of patients and clearance with CIRFs was achieved in 72 % of patients. Success rate could not be attributed to age, stone size or gender. Our outcome data for the treatment of lower pole renal stones (≤15 mm) compare favourably with the literature. With this level of stone clearance, a non-invasive, outpatient-based treatment like lithotripsy should remain the first-line treatment option for lower pole stones. Ureteroscopy must prove that it is significantly better either in terms of clinical outcome or patient satisfaction to justify replacing lithotripsy.

  14. A PATIENT WITH EPIDERMAL CYST IN MANDIBULA, SIMULTANEOUSLY ENUCLEATION OF EPIDERMAL CYST AND IMPLANT PLACEMENT:

    OpenAIRE

    Terzi, Mithat; Karaaslan, Fatih; Çalık, Muhammed; Dilsiz, Alparslan; Altun, Eren

    2015-01-01

    Dermoid cysts are malformations that rarely seen in oral mucosa and can be defined as an epidermoid when lining presents only epithelium. Epidermoid and dermoid cysts are rarely seen in intraosseous and there was a few report about their presentation in the jaws. The development in implant surfaces and surgical techniques has led to changes in treatment protocol such as immediate implant placement. Immediate implant placement has some advantages such as, reduction in the time of treat- ment a...

  15. Separable pole expansions in four-nucleon bound state calculations

    International Nuclear Information System (INIS)

    Sofianos, S.A.; Fiedeldey, H.; Haberzettl, H.; Sandhas, W.

    1982-04-01

    We compare the utility of the Generalized Unitary Pole Expansion (GUPE) and the Energy-Dependent Pole Expansion (EDPE) for the three-body subsystem amplitudes in four-body state calculations for a variety of separable and local nucleon-nucleon interactions. It is found that, with the EDPE, the four-body binding energy is well reproduced with only two terms each for the (2+2)- and the (3+1)-subsystem, respectively, while the GUPE requires three terms for the (3+1)-channel and four terms for the (2+2)-channel. We thus conclude that pole dominance is of greater importance for the GUPE than for EDPE, which works equally well for both types of subsystems. It is found that both methods, in particular the EDPE, converge more rapidly with increasing repulsion in the two-body interaction, i.e. the more realistic the interaction becomes. Both expansions require similar computing times for a converged calculation and are about 15-20 times faster than the widely used Hilbert-Schmidt Expansion (HSE). The respective merits of the two pole expansions are discussed and compared with the HSE. (orig.)

  16. Relay Placement for FSO Multihop DF Systems With Link Obstacles and Infeasible Regions

    KAUST Repository

    Zhu, Bingcheng

    2015-05-19

    Optimal relay placement is studied for free-space optical multihop communication with link obstacles and infeasible regions. An optimal relay placement scheme is proposed to achieve the lowest outage probability, enable the links to bypass obstacles of various geometric shapes, and place the relay nodes in specified available regions. When the number of relay nodes is large, the searching space can grow exponentially, and thus, a grouping optimization technique is proposed to reduce the searching time. We numerically demonstrate that the grouping optimization can provide suboptimal solutions close to the optimal solutions, but the average searching time linearly grows with the number of relay nodes. Two useful theorems are presented to reveal insights into the optimal relay locations. Simulation results show that our proposed optimization framework can effectively provide desirable solution to the problem of optimal relay nodes placement. © 2015 IEEE.

  17. Least 1-Norm Pole-Zero Modeling with Sparse Deconvolution for Speech Analysis

    DEFF Research Database (Denmark)

    Shi, Liming; Jensen, Jesper Rindom; Christensen, Mads Græsbøll

    2017-01-01

    In this paper, we present a speech analysis method based on sparse pole-zero modeling of speech. Instead of using the all-pole model to approximate the speech production filter, a pole-zero model is used for the combined effect of the vocal tract; radiation at the lips and the glottal pulse shape...

  18. Effect of poling process on piezoelectric properties of BCZT - 0.08 wt.% CeO{sub 2} lead-free ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Chandrakala, E.; Praveen, J. Paul; Das, Dibakar, E-mail: ddse@uohyd.ernet.in [School of Engineering Sciences & Technology, University of Hyderabad, Hyderabad 500046 (India)

    2016-05-06

    The properties of lead free piezoelectric materials can be tuned by suitable doping in the A and B sites of the perovskite structure. In the present study, cerium has been identified as a dopant to investigate the piezoelectric properties of lead-free BCZT system. BCZT – 0.08 wt.%CeO{sub 2} lead-free ceramics have been synthesized using sol-gel technique and the effects of CeO{sub 2} dopant on their phase structure and piezoelectric properties were investigated systematically. Poling conditions, such as temperature, electric field, and poling time have been optimized to get enhanced piezoelectric response. The optimized poling conditions (50°C, 3Ec and 30min) resulted in high piezoelectric charge coefficient d{sub 33} ~ 670pC/N, high electromechanical coupling coefficient k{sub p} ~ 60% and piezoelectric voltage coefficient g{sub 33} ~ 14 mV.m/N for BCZT – 0.08wt.% CeO{sub 2} ceramics.

  19. Placement suitability criteria of composite tape for mould surface in automated tape placement

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2015-10-01

    Full Text Available Automated tape placement is an important automated process used for fabrication of large composite structures in aeronautical industry. The carbon fiber composite parts realized with this process tend to replace the aluminum parts produced by high-speed machining. It is difficult to determine the appropriate width of the composite tape in automated tape placement. Wrinkling will appear in the tape if it does not suit for the mould surface. Thus, this paper deals with establishing placement suitability criteria of the composite tape for the mould surface. With the assumptions for ideal mapping and by applying some principles and theorems of differential geometry, the centerline trajectory of the composite tape is identified to follow the geodesic. The placement suitability of the composite tape is examined on three different types of non-developable mould surfaces and four criteria are derived. The developed criteria have been used to test the deposition process over several mould surfaces and the appropriate width for each mould surface is obtained by referring to these criteria.

  20. effect of number of rotor poles on ac losses of permanent magnet

    African Journals Online (AJOL)

    HOD

    A study on permanent magnet (PM) eddy current and core losses of dual-stator PM machines is investigated in this paper. ... material in the retaining sleeves of surface-mounted ... rotor-pole numbers (13-poleand 14-pole in particular) ... Table 2: Optimized Machine Parameters. Number of rotor poles. 4. 5. 7. 8. 10. 11. 13. 14.

  1. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  2. Influence of the absorptive part of the complex potential on the S-Matrix poles

    International Nuclear Information System (INIS)

    Grama, C.; Grama, N.; Zamfirescu, I

    2001-01-01

    Although the polology of the S-matrix has been extensively studied, it occurred that some aspects remained disputable in the case of complex central potential V(r)=gV(r), g in C . These aspects are related to the origin of the observed narrow Σ-hypernuclear states that have been interpreted by Gal, Toker and Alexander as states which correspond to S-matrix poles situated in the second k-plane quadrant. From the analytical properties of the S-matrix for a real potential it results that there is no pole in the first and second k-plane quadrants, except for the imaginary k-axis. By switching on the absorption the S-matrix poles for real potential can evolve into the second quadrant of the k-plane. A critical study of the Σ-hypernuclear states needs the analysis of the motion of the S-matrix poles in the k-plane for variable complex coupling strength g. Recently contradictory opinions relative to the S-matrix poles trajectories in the complex k-plane for a complex square potential occurred. According to some authors the poles in the second quadrant can occur either from bound state poles moving anticlockwise, or from virtual state poles and capture resonant state poles moving clockwise as the absorption is switched on. Dabrowski argues that the statement made by Gal et al, Bonetti et al and Oset et al concerning the movement of the virtual poles with increasing absorptive potential is in general not correct. Dabrowski relates the direction in which the pole moves when the potential absorption increases to the direction in which the pole moves with increasing the real part of the potential, without clarifying this last question. For example, two poles moving in opposite directions along the imaginary k-axis are associated by Dabrowski to the same state. This is a wrong result, because one should associate a single pole to each quantum state. The aim of our work is to study the influence of the absorptive part of the potential on the S-matrix poles for the non

  3. VT Green Mountain Power Pole Data

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) Green Mountain Power (GMP) pole and OVERHEAD linear distribution/sub-transmission model data. THE LINEAR DISTRIBUTION LAYER ONLY INCLUDES OVERHEAD...

  4. SPOT-A SENSOR PLACEMENT OPTIMIZATION TOOL FOR ...

    Science.gov (United States)

    journal article This paper presents SPOT, a Sensor Placement Optimization Tool. SPOT provides a toolkit that facilitates research in sensor placement optimization and enables the practical application of sensor placement solvers to real-world CWS design applications. This paper provides an overview of SPOT’s key features, and then illustrates how this tool can be flexibly applied to solve a variety of different types of sensor placement problems.

  5. Simultaneous Versus Sequential Side-by-Side Bilateral Metal Stent Placement for Malignant Hilar Biliary Obstructions.

    Science.gov (United States)

    Inoue, Tadahisa; Ishii, Norimitsu; Kobayashi, Yuji; Kitano, Rena; Sakamoto, Kazumasa; Ohashi, Tomohiko; Nakade, Yukiomi; Sumida, Yoshio; Ito, Kiyoaki; Nakao, Haruhisa; Yoneda, Masashi

    2017-09-01

    Endoscopic bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstructions (MHBOs) is technically demanding, and a second SEMS insertion is particularly challenging. A simultaneous side-by-side (SBS) placement technique using a thinner delivery system may mitigate these issues. We aimed to examine the feasibility and efficacy of simultaneous SBS SEMS placement for treating MHBOs using a novel SEMS that has a 5.7-Fr ultra-thin delivery system. Thirty-four patients with MHBOs underwent SBS SEMS placement between 2010 and 2016. We divided the patient cohort into those who underwent sequential (conventional) SBS placement between 2010 and 2014 (sequential group) and those who underwent simultaneous SBS placement between 2015 and 2016 (simultaneous group), and compared the groups with respect to the clinical outcomes. The technical success rates were 71% (12/17) and 100% (17/17) in the sequential and simultaneous groups, respectively, a difference that was significant (P = .045). The median procedure time was significantly shorter in the simultaneous group (22 min) than in the sequential group (52 min) (P = .017). There were no significant group differences in the time to recurrent biliary obstruction (sequential group: 113 days; simultaneous group: 140 days) or other adverse event rates (sequential group: 12%; simultaneous group: 12%). Simultaneous SBS placement using the novel 5.7-Fr SEMS delivery system may be more straightforward and have a higher success rate compared to that with sequential SBS placement. This new method may be useful for bilateral stenting to treat MHBOs.

  6. Low equation, pion-nucleon scattering, and Castillejo-Dalitz-Dyson pole

    International Nuclear Information System (INIS)

    Nakano, K.; Nogami, Y.

    1986-01-01

    We examine the p-wave πN scattering at medium energies by means of the Low equation with a view to determining the form factor of the πN interaction. Solutions of the equation with and without a Castillejo-Dalitz-Dyson (CDD) pole are used. The solution with no CDD pole corresponds to the old Chew-Low model, whereas the one with a CDD pole corresponds to the quark version of the Chew-Low model. The πN interaction form factor is determined so that the Δ resonance is well reproduced. We find that the solution with a CDD pole leads to a softer form factor but is not as soft as those expected from the nucleon size in the quark model. Using the solutions and form factors thus determined, we also examine the pionic contributions to the nucleon magnetic moment and the nucleon mass

  7. Design optimization for permanent magnet machine with efficient slot per pole ratio

    Science.gov (United States)

    Potnuru, Upendra Kumar; Rao, P. Mallikarjuna

    2018-04-01

    This paper presents a methodology for the enhancement of a Brush Less Direct Current motor (BLDC) with 6Poles and 8slots. In particular; it is focused on amulti-objective optimization using a Genetic Algorithmand Grey Wolf Optimization developed in MATLAB. The optimization aims to maximize the maximum output power value and minimize the total losses of a motor. This paper presents an application of the MATLAB optimization algorithms to brushless DC (BLDC) motor design, with 7 design parameters chosen to be free. The optimal design parameters of the motor derived by GA are compared with those obtained by Grey Wolf Optimization technique. A comparative report on the specified enhancement approaches appearsthat Grey Wolf Optimization technique has a better convergence.

  8. A Randomized Controlled Trial of Music Use During Epidural Catheter Placement on Laboring Parturient Anxiety, Pain, and Satisfaction.

    Science.gov (United States)

    Drzymalski, Dan M; Tsen, Lawrence C; Palanisamy, Arvind; Zhou, Jie; Huang, Chuan-Chin; Kodali, Bhavani S

    2017-02-01

    Although music is frequently used to promote a relaxing environment during labor and delivery, the effect of its use during the placement of neuraxial techniques is unknown. Our study sought to determine the effects of music use on laboring parturients during epidural catheter placement, with the hypothesis that music use would result in lower anxiety, lower pain, and greater patient satisfaction. We conducted a prospective, randomized, controlled trial of laboring parturients undergoing epidural catheter placement with or without music. The music group listened to the patient's preferred music on a Pandora® station broadcast through an external amplified speaker; the control group listened to no music. All women received a standardized epidural technique and local anesthetic dose. The primary outcomes were 3 measures of anxiety. Secondary outcomes included pain, patient satisfaction, hemodynamic parameters, obstetric parameters, neonatal outcomes, and anesthesia provider anxiety. Intention-to-treat analysis with Bonferroni correction was used for the primary outcomes. For secondary outcomes, a P value of music group, the duration of music use was 31.1 ± 7.7 minutes (mean ± SD). The music group experienced higher anxiety as measured by Numeric Rating Scale scores immediately after epidural catheter placement (2.9 ± 3.3 vs 1.4 ± 1.7, mean difference 1.5 [95% confidence interval {CI} 0.2-2.7], P = .02), and as measured by fewer parturients being "very much relaxed" 1 hour after epidural catheter placement (51% vs 78%, odds ratio {OR} 0.3 [95% CI 0.1-0.9], P = .02). No differences in mean pain scores immediately after placement or patient satisfaction with the overall epidural placement experience were observed; however, the desire for music use with future epidural catheter placements was higher in the music group (84% vs 45%, OR 6.4 [95% CI 2.5-16.5], P Music use during epidural catheter placement in laboring parturients is associated with higher postprocedure

  9. Double Trouble: A Rare Case of Bilateral Upper Pole Ureteropelvic Junction Obstruction

    Directory of Open Access Journals (Sweden)

    Craig A. Peters

    2014-09-01

    Full Text Available A 16-year-old girl presented with bilateral back pain caused by bilateral upper pole ureteropelvic junction obstructions; an extremely rare phenomenon. Bilateral robotically assisted upper pole pyeloplasties were preformed at the same setting with an excellent clinical response. Although rare, upper pole ureteropelvic junction obstruction is a defined entity that urologists should be aware of.

  10. Poles near the thresholds in the coupled ΛN - ΣN system

    International Nuclear Information System (INIS)

    Yamamura, H.; Miyagawa, K.

    1999-01-01

    We find t-matrix poles near the ΣN threshold for the meson theoretical Nijmegen YN interactions including hard-core models. These poles are connected with the strength of the ΛN - ΣN coupling. We also observe antibound-state poles below the ΛN threshold which correlate with scattering lengths. Refs. 4, tabs. 2 (author)

  11. Design of an adaptive pole assignment controller for steam generators and its experimental study

    International Nuclear Information System (INIS)

    Na, Man Gyun; No, Hee Cheon

    1992-01-01

    An adaptive observer is designed that both parameters and state variables of the steam generator are estimated simultaneously. A pole assignment controller is derived on the basis of the adaptive observer. The characteristics of the overall closed-loop control system can be expressed in terms of its poles, assigned poles. The troublesome tuning procedure of the P-I controller is reduced to the determination of the desired poles only. The proposed algorithm is compared with the conventional P-I controller through numerical simulation. Also, the adaptive pole assignment controller is studied experimentally by implementing it to the mock-up of the nuclear steam generator. The adaptive pole assignment controller shows better responses than the P-l controller does. (Author)

  12. Field analysis and enhancement of multi-pole magnetic components fabricated on printed circuit board

    International Nuclear Information System (INIS)

    Chiu, K.-C.; Chen, C.-S.

    2007-01-01

    A multi-pole magnetic component magnetized with a fine magnetic pole pitch of less than 1 mm is very difficult to achieve by using traditional methods. Moreover, it requires a precise mechanical process and a complicated magnetization system. Different fine magnetic pole pitches of 300, 350 and 400 μm have been accomplished on 9-pole magnetic components through the printed circuit board (PCB) manufacturing technology. Additionally, another fine magnetic pole pitch of 500 μm was also fabricated on a dual-layered (DL) wire circuit structure to investigate the field enhancement. After measurements, a gain factor of 1.37 was obtained in the field strength. The field variations among different magnetic pole pitches were analyzed in this paper

  13. The self-consistent dynamic pole tide in non-global oceans

    Science.gov (United States)

    Dickman, S. R.

    1988-01-01

    The dynamic pole tide is determined by solving Laplace tide equations which take into account the presence of continents in oceans, oceanic self-gravitation and loading, and mantle elasticity. Dynamical effects are found to be only mild. It is shown that the dynamical pole tide contributes about one day more to the Chandler period than a static pole tide would, and dissipates wobble energy at a very weak rate. It is noted that, depending on the wobble period predicted for an oceanless elastic earth, mantle anelasticity at low frequencies may nevertheless contribute negligibly to the Chandler period.

  14. Differences in Some Kinematic Parameters between Two Qualitatively Different Groups of Pole Vaulters.

    Science.gov (United States)

    Gudelj, Ines; Babić, Vesna; Milat, Sanja; Čavala, Marijana; Zagorac, Siniša; Katić, Ratko

    2015-07-01

    The basic aim of this research was to determine the differences of kinematic parameters in two qualitatively different groups of young pole vaulters. With this purpose, a research was conducted in which the video records from a competition were acquired. The sample of entities (N = 71) consisted of successful vaults of 30 pole vaulters, whose attempts were recorded at the European Junior Championship in Novi Sad, held on 23-26th July 2009. The examinees performed the vaults as a part of the elimination competition for the finals, and during the final part of the competition. The age of examinees was from 17 to 19 years, and the span of their best results was from 4.70 to 5.30 meters. The kinematic analysis was conducted according to the standards of APAS procedure (Ariel Performance Analysis System, USA), determining 25 kinematic variables necessary for further analysis. The entities (vaults) were divided into two categories (qualitative classes) based on the expert knowledge. Group 1 consisted of successful vaults up to 4.90 m (N = 46), while group 2 consisted of successful vaults whose height was more than 4.90 m (N = 25). The discrimination analysis determined the parameters differentiating the vaults of different quantitative classes. Also, it was confirmed that the result efficiency in pole vault was primarily determined by the variables defined by motor abilities, as well as the indicators determining the vault performance technique.

  15. Prospective implementation of an algorithm for bedside intravascular ultrasound-guided filter placement in critically ill patients.

    Science.gov (United States)

    Killingsworth, Christopher D; Taylor, Steven M; Patterson, Mark A; Weinberg, Jordan A; McGwin, Gerald; Melton, Sherry M; Reiff, Donald A; Kerby, Jeffrey D; Rue, Loring W; Jordan, William D; Passman, Marc A

    2010-05-01

    Although contrast venography is the standard imaging method for inferior vena cava (IVC) filter insertion, intravascular ultrasound (IVUS) imaging is a safe and effective option that allows for bedside filter placement and is especially advantageous for immobilized critically ill patients by limiting resource use, risk of transportation, and cost. This study reviewed the effectiveness of a prospectively implemented algorithm for IVUS-guided IVC filter placement in this high-risk population. Current evidence-based guidelines were used to create a clinical decision algorithm for IVUS-guided IVC filter placement in critically ill patients. After a defined lead-in phase to allow dissemination of techniques, the algorithm was prospectively implemented on January 1, 2008. Data were collected for 1 year using accepted reporting standards and a quality assurance review performed based on intent-to-treat at 6, 12, and 18 months. As defined in the prospectively implemented algorithm, 109 patients met criteria for IVUS-directed bedside IVC filter placement. Technical feasibility was 98.1%. Only 2 patients had inadequate IVUS visualization for bedside filter placement and required subsequent placement in the endovascular suite. Technical success, defined as proper deployment in an infrarenal position, was achieved in 104 of the remaining 107 patients (97.2%). The filter was permanent in 21 (19.6%) and retrievable in 86 (80.3%). The single-puncture technique was used in 101 (94.4%), with additional dual access required in 6 (5.6%). Periprocedural complications were rare but included malpositioning requiring retrieval and repositioning in three patients, filter tilt >/=15 degrees in two, and arteriovenous fistula in one. The 30-day mortality rate for the bedside group was 5.5%, with no filter-related deaths. Successful placement of IVC filters using IVUS-guided imaging at the bedside in critically ill patients can be established through an evidence-based prospectively

  16. Chemical placement in heterogeneous and long reach horizontal wells

    Energy Technology Data Exchange (ETDEWEB)

    Stalker, Robert; Wahid, Fazrie; Graham, Gordon M.

    2006-03-15

    The effective placement of chemical squeeze treatments in heterogeneous wells and long reach horizontal wells has proved a significant challenge, with various factors including heterogeneity, crossflow and pressure gradients between otherwise non-communicating zones within the well, all contributing to an uneven placement of the scale squeeze treatment into the reservoir. Current methods to circumvent these problems often rely on extremely expensive coiled tubing operations, staged diversion (temporary shut off) treatments or by designing treatments to deliberately overdose some zones in order to gain placement in other (e.g. low permeability) zones. Moreover for deepwater sub sea horizontal wells the costs associated with ''spot'' treating along the length of horizontal wells by coil tubing tractor operations can often be prohibitively expensive. For other very near well bore treatments such as acid stimulation a number of self diverting strategies including gelled acid treatments, staged viscoelastic surfactant treatments and foams have been applied in field treatments with some success. However the properties which make such treatments applicable for acid stimulation may also make them inappropriate for bullhead scale squeeze treatments. Recent work by the current authors has however indicated the possible benefits of using modified injection fluids to aid uniform scale inhibitor placement in such wells in order to effect more even placement. In summary this paper will describe the various options available for achieving self diversion and describes the potential drawbacks associated with the viscous placement fluids commonly used for acid simulation techniques. In addition, various simulation packages commonly used for scale related calculations are reviewed and their limitations, primarily due to the inherent assumptions made and input parameters used, for modelling squeeze treatments using such modified fluids are described. The paper

  17. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  18. Sun's pole-equator flux differences

    Energy Technology Data Exchange (ETDEWEB)

    Belvedere, G [Istituto di Astronomia dell' Universita di Catania, Italy; Paterno, L [Osservatorio Astrofisico di Catania, Italy

    1977-04-01

    The possibility that large flux differences between the poles and the equator at the bottom of the solar convective zone are compatible with the small differences observed at the surface is studied. The consequences of increasing the depth of the convective zone due to overshooting are explored. A Boussinesq model is used for the convective zone and it is assumed that the interaction of the global convection with rotation is modelled through a convective flux coefficient whose perturbed part is proportional to the local Taylor number. The numerical integration of the equations of motion and energy shows that coexistence between large pole-equator flux differences at the bottom and small ones at the surface is possible if the solar convective zone extends to a depth of 0.4 R(Sun). The angular velocity distribution inside the convective zone is in agreement with the ..cap alpha omega..-dynamo theories of the solar cycle.

  19. INNOVATIVE CLUSTER OR COMPETITIVENESS POLE?

    Directory of Open Access Journals (Sweden)

    Liliana Scutaru

    2015-02-01

    Full Text Available The paper analyzes the situation of clusters in Romania and their areas of activity and innovation in entrepreneurship Romanian state. It is made also a territorial distribution of clusters on the eight regions. The findings lead to the conclusion that there are some clusters that have the vocation to become poles of competitiveness in areas such as renewable energy, automotive, electronics, health, biotechnology, mechatronics or ICT (Information and Communication Technology which represent the resources for future of the Romanian economy. Regarding the degree of innovation of Romanian Small and Medium Enterprises (SMEs, the level is relatively modest, 30.8% of all enterprises being innovative. If we were to answer the question the title suggests, we would say "yes" to both since the innovative cluster as well as the competitiveness pole promotes par excellence, innovation through study, research and stimulation of creativity. And this is more than enough to support economic growth of Romania and maintain the competitiveness worldwide.

  20. POLE proofreading mutations elicit an anti-tumor immune response in endometrial cancer

    Science.gov (United States)

    van Gool, Inge C; Eggink, Florine A; Freeman-Mills, Luke; Stelloo, Ellen; Marchi, Emanuele; de Bruyn, Marco; Palles, Claire; Nout, Remi A; de Kroon, Cor D; Osse, Elisabeth M; Klenerman, Paul; Creutzberg, Carien L; Tomlinson, Ian PM; Smit, Vincent THBM; Nijman, Hans W

    2015-01-01

    Purpose Recent studies have shown that 7-12% of endometrial cancers (ECs) are ultramutated due to somatic mutation in the proofreading exonuclease domain of the DNA replicase POLE. Interestingly, these tumors have an excellent prognosis. In view of the emerging data linking mutation burden, immune response and clinical outcome in cancer, we investigated whether POLE-mutant ECs showed evidence of increased immunogenicity. Experimental design We examined immune infiltration and activation according to tumor POLE proofreading mutation in a molecularly defined EC cohort including 47 POLE-mutant tumors. We sought to confirm our results by analysis of RNAseq data from the TCGA EC series and used the same series to examine whether differences in immune infiltration could be explained by an enrichment of immunogenic neoepitopes in POLE-mutant ECs. Results Compared to other ECs, POLE-mutants displayed an enhanced cytotoxic T cell response, evidenced by increased numbers of CD8+ tumor infiltrating lymphocytes and CD8A expression, enrichment for a tumor-infiltrating T cell gene signature, and strong upregulation of the T cell cytotoxic differentiation and effector markers T-bet, Eomes, IFNG, PRF and granzyme B. This was accompanied by upregulation of T cell exhaustion markers, consistent with chronic antigen exposure. In-silico analysis confirmed that POLE-mutant cancers are predicted to display more antigenic neo-epitopes than other ECs, providing a potential explanation for our findings. Conclusions Ultramutated POLE proofreading-mutant ECs are characterized by a robust intratumoral T cell response, which correlates with, and may be caused by an enrichment of antigenic neo-peptides. Our study provides a plausible mechanism for the excellent prognosis of these cancers. PMID:25878334

  1. Personaliotsinguteenust tasub kasutada siis, kui rahaline kokkuhoid pole esmane / Merike Lees

    Index Scriptorium Estoniae

    Lees, Merike, 1976-

    2006-01-01

    Ilmunud ka: Delovõje Vedomosti 1. veebr. lk. 13. Personaliotsinguteenuse kasutamine on õigustatud siis, kui ettevõttes pole personalispetsialisti ning rahaline kokkuhoid pole esmatähtis. Kommenteerivad: Eero Erastus, Madis Sander ja Marti Rehemaa

  2. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories.

    Science.gov (United States)

    Hélie, Sonia; Poirier, Marie-Andrée; Esposito, Tonino; Turcotte, Daniel

    2017-11-17

    Objectives : The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1) to examine trends in placement use and placement stability since the reform and (2) to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform ( n = 9620, 8676, 8425). Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results : There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions : The results suggest interesting avenues for policy makers and service providers to improve

  3. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories

    Directory of Open Access Journals (Sweden)

    Sonia Hélie

    2017-11-01

    Full Text Available Objectives: The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1 to examine trends in placement use and placement stability since the reform and (2 to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform (n = 9620, 8676, 8425. Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results: There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions: The results suggest interesting avenues for policy makers and service

  4. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories

    Science.gov (United States)

    Hélie, Sonia; Poirier, Marie-Andrée; Esposito, Tonino; Turcotte, Daniel

    2017-01-01

    Objectives: The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1) to examine trends in placement use and placement stability since the reform and (2) to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform (n = 9620, 8676, 8425). Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results: There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions: The results suggest interesting avenues for policy makers and service providers to improve the

  5. Secondary electron emission yield on poled silica based thick films

    DEFF Research Database (Denmark)

    Braga, D.; Poumellec, B.; Cannas, V.

    2004-01-01

    Studies on the distribution of the electric field produced by a thermal poling process in a layer of Ge-doped silica on silicon substrate, by using secondary electron emission yield (SEEY) measurements () are presented. Comparing 0 between poled and unpoled areas, the SEEY at the origin of electr...

  6. Wiring economy and volume exclusion determine neuronal placement in the Drosophila brain.

    Science.gov (United States)

    Rivera-Alba, Marta; Vitaladevuni, Shiv N; Mishchenko, Yuriy; Mischenko, Yuriy; Lu, Zhiyuan; Takemura, Shin-Ya; Scheffer, Lou; Meinertzhagen, Ian A; Chklovskii, Dmitri B; de Polavieja, Gonzalo G

    2011-12-06

    Wiring economy has successfully explained the individual placement of neurons in simple nervous systems like that of Caenorhabditis elegans [1-3] and the locations of coarser structures like cortical areas in complex vertebrate brains [4]. However, it remains unclear whether wiring economy can explain the placement of individual neurons in brains larger than that of C. elegans. Indeed, given the greater number of neuronal interconnections in larger brains, simply minimizing the length of connections results in unrealistic configurations, with multiple neurons occupying the same position in space. Avoiding such configurations, or volume exclusion, repels neurons from each other, thus counteracting wiring economy. Here we test whether wiring economy together with volume exclusion can explain the placement of neurons in a module of the Drosophila melanogaster brain known as lamina cartridge [5-13]. We used newly developed techniques for semiautomated reconstruction from serial electron microscopy (EM) [14] to obtain the shapes of neurons, the location of synapses, and the resultant synaptic connectivity. We show that wiring length minimization and volume exclusion together can explain the structure of the lamina microcircuit. Therefore, even in brains larger than that of C. elegans, at least for some circuits, optimization can play an important role in individual neuron placement. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Clusters of cyclones encircling Jupiter’s poles

    Science.gov (United States)

    Adriani, A.; Mura, A.; Orton, G.; Hansen, C.; Altieri, F.; Moriconi, M. L.; Rogers, J.; Eichstädt, G.; Momary, T.; Ingersoll, A. P.; Filacchione, G.; Sindoni, G.; Tabataba-Vakili, F.; Dinelli, B. M.; Fabiano, F.; Bolton, S. J.; Connerney, J. E. P.; Atreya, S. K.; Lunine, J. I.; Tosi, F.; Migliorini, A.; Grassi, D.; Piccioni, G.; Noschese, R.; Cicchetti, A.; Plainaki, C.; Olivieri, A.; O’Neill, M. E.; Turrini, D.; Stefani, S.; Sordini, R.; Amoroso, M.

    2018-03-01

    The familiar axisymmetric zones and belts that characterize Jupiter’s weather system at lower latitudes give way to pervasive cyclonic activity at higher latitudes. Two-dimensional turbulence in combination with the Coriolis β-effect (that is, the large meridionally varying Coriolis force on the giant planets of the Solar System) produces alternating zonal flows. The zonal flows weaken with rising latitude so that a transition between equatorial jets and polar turbulence on Jupiter can occur. Simulations with shallow-water models of giant planets support this transition by producing both alternating flows near the equator and circumpolar cyclones near the poles. Jovian polar regions are not visible from Earth owing to Jupiter’s low axial tilt, and were poorly characterized by previous missions because the trajectories of these missions did not venture far from Jupiter’s equatorial plane. Here we report that visible and infrared images obtained from above each pole by the Juno spacecraft during its first five orbits reveal persistent polygonal patterns of large cyclones. In the north, eight circumpolar cyclones are observed about a single polar cyclone; in the south, one polar cyclone is encircled by five circumpolar cyclones. Cyclonic circulation is established via time-lapse imagery obtained over intervals ranging from 20 minutes to 4 hours. Although migration of cyclones towards the pole might be expected as a consequence of the Coriolis β-effect, by which cyclonic vortices naturally drift towards the rotational pole, the configuration of the cyclones is without precedent on other planets (including Saturn’s polar hexagonal features). The manner in which the cyclones persist without merging and the process by which they evolve to their current configuration are unknown.

  8. TERRITORIAL COHESION AND LOCAL DEVELOPMENT USING EUROPEAN STRUCTURAL AND COHESION FUNDS AT THE LEVEL OF GROWTH POLES – CASE STUDY GROWTH POLE BRASOV

    Directory of Open Access Journals (Sweden)

    Aida Petronela CATANA

    2015-08-01

    Full Text Available The growth poles were established in Romania in 2008 as centers for urban development in compliance with European and national policies and they include an urban nucleus and its rural surroundings.  According to the legal framework, for each of the growth poles an Integrated Development Plan should be adopted as basis for European Structural and Cohesion Funds investments. This is a new document in addition to local development plans/strategies of the local communities or counties and regional development plans. From another point of view, the growth poles are representing teritorial units which have to assure territorial cohesion for its urban and rural administrative units. Into this respect, there are different spatial planning documents which have to be followed by the territorial and administrative units, according to the Romanian legislation. Beyond these, there are rules and compulsory criterias for accessing European Structural and Cohesion funds the problems being faced by the associations established by local communities in order to manage the growth poles’s areas. Taking into account all these, we may say that growth poles are the crossing points for different policies translated into plans and operational programmes’s criterias for getting ESC Funds.

  9. Don't trust equivalency presumptions when choosing distribution poles

    Energy Technology Data Exchange (ETDEWEB)

    Rollins, M.

    2003-08-01

    The variety of electric power distribution poles are described (wood, steel, prestressed concrete) in an effort to alert utilities that simple substitution of one type of pole for another based on presumed equivalency entails the risk that the replacement poles are unfit for the load conditions and do not comply with National Electrical Safety Code (NESC) requirements. A thorough evaluation of all design loads and the proper application of the appropriate overload and strength factors must take place prior to selecting the type of replacement to avoid misapplication of a product in situations for which it was not designed. Relevant provisions of NESC are described.

  10. Russians, Jews, and Poles: Russification and Antisemitism 1881-1914

    Directory of Open Access Journals (Sweden)

    Theodor R. Weeks

    2012-07-01

    Full Text Available Relations between Poles and Jews deteriorated significantly in the three decades leading up to World War I. Many reasons for this phenomenon can be given, for example: economic competition, a general atmosphere of acute nationalism, increased migration, perceived threats to traditional forms of life and religion. Exacerbating all of these factors, however, was the fact of Polish statelessness and the extreme sensitivity of Poles to perceived threats to their culture and nation. In particular within the Russian Empire, Poles perceived the very future of their nation at risk. In such circumstances the continued existence of Jewish cultural difference combined with the development of specifically Jewish forms of national awakening (e.g., the Bund and Zionism were understood by many in Polish society as ingratitude and collaboration with the Russian occupier

  11. Investigation of experimental pole-figure errors by simulation of individual spectra

    International Nuclear Information System (INIS)

    Lychagina, T. A.; Nikolaev, D. I.

    2007-01-01

    The errors in measuring the crystallographic texture described by pole figures are studied. A set of diffraction spectra for a sample of the MA2-1 alloy (Mg + 4.5% Al + 1% Zn) are measured, simulation of individual spectra on the basis of which the pole figures were obtained is performed, and their errors are determined. The conclusion about the possibility of determining the effect of errors of the diffraction peak half-width on the pole figure errors that was drawn in our previous studies is confirmed

  12. Investigation Effects of Narrowing Rotor Pole Embrace to Efficiency and Cogging Torque at PM BLDC Motor

    Directory of Open Access Journals (Sweden)

    Cemil Ocak

    2016-02-01

    Full Text Available Engineers think that pole embrace size of a PM BLDC motor affects directly the efficiency and the torque. Dealing with theexperimental research, in the studywe have investigated the effects of narrowing rotor pole embrace step by step by changing sizes parametrically. By doing so, high efficiency and low cogging torque would have been obtained for a 20 W PM BLDC motor. In order to do this,pole arc to pole pitch ratio of magnets at the rotor poles has been changed parametrically (0.5 to 1 by genetic algorithm methodfirst. Then the electromagnetic field dispersions, output parameters of the motor, new rotor constructions have been obtained; and new pole embrace has been derived from the variation of pole arc to pole pitch ratio. We have also calculatedthe magnetic flux distribution, output power, torque, cogging torque and efficiency values analytically and the effects of new pole embrace to motor efficiency and torque have been simulated. The developed 18 slots, 6 poles, surface mounted inner runner configuration rotor machine is proposed as to be used insmall dentistry apparatus.

  13. Periodically poled silicon

    Science.gov (United States)

    Hon, Nick K.; Tsia, Kevin K.; Solli, Daniel R.; Khurgin, Jacob B.; Jalali, Bahram

    2010-02-01

    Bulk centrosymmetric silicon lacks second-order optical nonlinearity χ(2) - a foundational component of nonlinear optics. Here, we propose a new class of photonic device which enables χ(2) as well as quasi-phase matching based on periodic stress fields in silicon - periodically-poled silicon (PePSi). This concept adds the periodic poling capability to silicon photonics, and allows the excellent crystal quality and advanced manufacturing capabilities of silicon to be harnessed for devices based on χ(2)) effects. The concept can also be simply achieved by having periodic arrangement of stressed thin films along a silicon waveguide. As an example of the utility, we present simulations showing that mid-wave infrared radiation can be efficiently generated through difference frequency generation from near-infrared with a conversion efficiency of 50% based on χ(2) values measurements for strained silicon reported in the literature [Jacobson et al. Nature 441, 199 (2006)]. The use of PePSi for frequency conversion can also be extended to terahertz generation. With integrated piezoelectric material, dynamically control of χ(2)nonlinearity in PePSi waveguide may also be achieved. The successful realization of PePSi based devices depends on the strength of the stress induced χ(2) in silicon. Presently, there exists a significant discrepancy in the literature between the theoretical and experimentally measured values. We present a simple theoretical model that produces result consistent with prior theoretical works and use this model to identify possible reasons for this discrepancy.

  14. Avoidance of a Landau pole by flat contributions in QED

    Energy Technology Data Exchange (ETDEWEB)

    Klaczynski, Lutz, E-mail: lutz.klaczynski@gmx.de [Department of Physics, Humboldt University Berlin, 12489 Berlin (Germany); Kreimer, Dirk, E-mail: kreimer@mathematik.hu-berlin.de [Alexander von Humboldt Chair in Mathematical Physics, Humboldt University, Berlin 12489 (Germany)

    2014-05-15

    We consider massless Quantum Electrodynamics in the momentum scheme and carry forward an approach based on Dyson–Schwinger equations to approximate both the β-function and the renormalized photon self-energy (Yeats, 2011). Starting from the Callan–Symanzik equation, we derive a renormalization group (RG) recursion identity which implies a non-linear ODE for the anomalous dimension and extract a sufficient but not necessary criterion for the existence of a Landau pole. This criterion implies a necessary condition for QED to have no such pole. Solving the differential equation exactly for a toy model case, we integrate the corresponding RG equation for the running coupling and find that even though the β-function entails a Landau pole it exhibits a flat contribution capable of decreasing its growth, in other cases possibly to the extent that such a pole is avoided altogether. Finally, by applying the recursion identity, we compute the photon propagator and investigate the effect of flat contributions on both spacelike and timelike photons. -- Highlights: •We present an approach to approximate both the β-function and the photon self-energy. •We find a sufficient criterion for the self-energy to entail the existence of a Landau pole. •We study non-perturbative ‘flat’ contributions that emerge within the context of our approach. •We discuss a toy model and how it is affected by flat contributions.

  15. Two-Phase Algorithm for Optimal Camera Placement

    Directory of Open Access Journals (Sweden)

    Jun-Woo Ahn

    2016-01-01

    Full Text Available As markers for visual sensor networks have become larger, interest in the optimal camera placement problem has continued to increase. The most featured solution for the optimal camera placement problem is based on binary integer programming (BIP. Due to the NP-hard characteristic of the optimal camera placement problem, however, it is difficult to find a solution for a complex, real-world problem using BIP. Many approximation algorithms have been developed to solve this problem. In this paper, a two-phase algorithm is proposed as an approximation algorithm based on BIP that can solve the optimal camera placement problem for a placement space larger than in current studies. This study solves the problem in three-dimensional space for a real-world structure.

  16. Comparison of bougie-guided insertion of Proseal tm laryngeal mask airway with digital technique in adults

    Directory of Open Access Journals (Sweden)

    Anand Kuppusamy

    2010-01-01

    Full Text Available The Proseal TM laryngeal mask airway (PLMA TM , Laryngeal Mask Company, UK was designed to improve ventilatory characteristics and offer protection against regurgitation and gastric insufflation. The PLMA is a modified laryngeal mask airway with large ventral cuff, dorsal cuff and a drain tube. These modifications improve seal around glottis and enable better ventilatory characteristics. The drain tube prevents gastric distension and offers protection against aspiration. There were occasional problems, like failed insertion and inadequate ventilation, in placing PLMA TM using the classical digital technique. To overcome these problems, newer placement techniques like thumb insertion technique, introducer tool placement and gum elastic bougie (GEB-aided placement were devised. We compared classical digital placement of PLMA TM with gum elastic bougie-aided technique in 60 anaesthetised adult patients (with 30 patients in each group with respect to number of attempts to successful placement, effective airway time, airway trauma during insertion, postoperative airway morbidity and haemodynamic response to insertion. The number of attempts to successful placement, airway trauma during insertion and haemodynamic response to insertion were comparable among the two groups, while effective airway time and oropharyngeal leak pressure were significantly higher in bougie- guided insertion of PLMA. Postoperatively, sore throat was more frequent with digital technique while dysphagia was more frequent with bougie-guided technique. Hence gum elastic bougie guided, laryngoscope aided insertion of PLMA is an excellent alternate to classical digital technique.

  17. Optimal sensor placement for leakage detection and isolation in water distribution networks

    OpenAIRE

    Rosich Oliva, Albert; Sarrate Estruch, Ramon; Nejjari Akhi-Elarab, Fatiha

    2012-01-01

    In this paper, the problem of leakage detection and isolation in water distribution networks is addressed applying an optimal sensor placement methodology. The chosen technique is based on structural models and thus it is suitable to handle non-linear and large scale systems. A drawback of this technique arises when costs are assigned uniformly. A main contribution of this paper is the proposal of an iterative methodology that focuses on identifying essential sensors which ultimately leads to...

  18. Mathematics Placement at the University of Illinois

    Science.gov (United States)

    Ahlgren Reddy, Alison; Harper, Marc

    2013-01-01

    Data from the ALEKS-based placement program at the University of Illinois is presented visually in several ways. The placement exam (an ALEKS assessment) contains precise item-specific information and the data show many interesting properties of the student populations of the placement courses, which include Precalculus, Calculus, and Business…

  19. Integrated fiber Michelson interferometer based on poled hollow twin-core fiber.

    Science.gov (United States)

    Liu, Zhihai; Bo, Fusen; Wang, Lei; Tian, Fengjun; Yuan, Libo

    2011-07-01

    We propose an integrated fiber Michelson interferometer based on a poled hollow twin-core fiber. The Michelson interferometer can be used as an electro-optic modulator by thermal poling one core of the twin-core fiber and introducing second-order nonlinearity in the fiber. The proposed fiber Michelson interferometer is experimentally demonstrated under driving voltages at the frequency range of 149 to 1000 Hz. The half-wave voltage of the poled fiber is 135 V, and the effective second-order nonlinear coefficient χ² is 1.23 pm/V.

  20. Product placement of computer games in cyberspace.

    Science.gov (United States)

    Yang, Heng-Li; Wang, Cheng-Shu

    2008-08-01

    Computer games are considered an emerging media and are even regarded as an advertising channel. By a three-phase experiment, this study investigated the advertising effectiveness of computer games for different product placement forms, product types, and their combinations. As the statistical results revealed, computer games are appropriate for placement advertising. Additionally, different product types and placement forms produced different advertising effectiveness. Optimum combinations of product types and placement forms existed. An advertisement design model is proposed for use in game design environments. Some suggestions are given for advertisers and game companies respectively.

  1. Optimizing detection of road furniture (pole-like object in Mobile Laser Scanner data

    Directory of Open Access Journals (Sweden)

    D. Li

    2013-10-01

    Full Text Available Due to the road safety problem is becoming more and more serious recent years, existing road safety assessment by using automatic method is necessary. Meanwhile, since the pole-like objects have large effect on road safety and are in high demand as facilities to be managed, the automatic pole-like objects extraction is becoming a hot issue. As a result, a robust, quick and automatic pole-like object detection algorithm in MLS data is proposed in this paper. Two datasets are tested to show performance of the proposed algorithm, it demonstrates that it is feasible to detect tree with an overall accuracy of over 92% and other pole-like object of 72% in dataset A and 82% of tree points and 75% of other pole points in dataset B.

  2. Technical errors in complete mouth radiographic survey according to radiographic techniques and film holding methods

    International Nuclear Information System (INIS)

    Choi, Karp Sik; Byun, Chong Soo; Choi, Soon Chul

    1986-01-01

    The purpose of this study was to investigate the numbers and causes of retakes in 300 complete mouth radiographic surveys made by 75 senior dental students. According to radiographic techniques and film holding methods, they were divided into 4 groups: Group I: Bisecting-angle technique with patient's fingers. Group II: Bisecting-angle technique with Rinn Snap-A-Ray device. Group III: Bisecting-angle technique with Rinn XCP instrument (short cone) Group IV: Bisecting-angle technique with Rinn XCP instrument (long cone). The most frequent cases of retakes, the most frequent tooth area examined, of retakes and average number of retakes per complete mouth survey were evaluated. The obtained results were as follows: Group I: Incorrect film placement (47.8), upper canine region, and 0.89. Group II: Incorrect film placement (44.0), upper canine region, and 1.12. Group III: Incorrect film placement (79.2), upper canine region, and 2.05. Group IV: Incorrect film placement (67.7), upper canine region, and 1.69.

  3. Stent placement under fluoroscopic monitoring and endoscopic direct vision for the treatment of malignant gastroduodenal obstruction: a report of 47 cases

    International Nuclear Information System (INIS)

    Zhang Baoyang; Li Weiping; Jiang Haosheng; Liu Shiyi; Hu Yi

    2009-01-01

    Objective: To discuss the operational technique and clinical effect of metallic stent placement in treating malignant gastroduodenal obstruction. Methods: Metallic stent placement under fluoroscopic monitoring and endoscopic direct vision was performed in 47 patients with malignant gastroduodenal obstruction. A total of 54 metallic stents was used. Results: The procedure was successfully completed in all 47 patients. During the follow-up period, all the patients could take liquid or ordinary diet and were markedly relived of vomiting. The living quality was much improved and no serious complications occurred. Conclusion: Under fluoroscopic monitoring and endoscopic direct vision, stent placement is a safe, effective, technically-simple and time-saving procedure for the treatment of malignant gastroduodenal obstruction with less sufferings to the patient. Therefore, it is definitely worth popularizing this technique in clinical practice. (authors)

  4. In-situ poling and structurization of piezoelectric particulate composites.

    Science.gov (United States)

    Khanbareh, H; van der Zwaag, S; Groen, W A

    2017-11-01

    Composites of lead zirconate titanate particles in an epoxy matrix are prepared in the form of 0-3 and quasi 1-3 with different ceramic volume contents from 10% to 50%. Two different processing routes are tested. Firstly a conventional dielectrophoretic structuring is used to induce a chain-like particle configuration, followed by curing the matrix and poling at a high temperature and under a high voltage. Secondly a simultaneous combination of dielectrophoresis and poling is applied at room temperature while the polymer is in the liquid state followed by subsequent curing. This new processing route is practiced in an uncured thermoset system while the polymer matrix still possess a relatively high electrical conductivity. Composites with different degrees of alignment are produced by altering the magnitude of the applied electric field. A significant improvement in piezoelectric properties of quasi 1-3 composites can be achieved by a combination of dielectrophoretic alignment of the ceramic particles and poling process. It has been observed that the degree of structuring as well as the functional properties of the in-situ structured and poled composites enhance significantly compared to those of the conventionally manufactured structured composites. Improving the alignment quality enhances the piezoelectric properties of the particulate composites.

  5. T-configured Dual Stent Placement in Malignant Biliary Hilar Obstruction: Technique and Clinical Application

    International Nuclear Information System (INIS)

    Jeon, Yong Sik; Kim, Ji Hyung

    2010-01-01

    To evaluate implanting techniques of T-configured dual stents in malignant hilar obstruction and investigate the clinical factors related to stent obstruction. The study included 28 patients undergoing T-configured dual stent implantation to palliate malignant biliary hilar obstruction. The unilobar approach was first attempted in the procedure, which progressed to bilobar approach when it was found that the unilobar approach was not feasible. If the stent was again obstructed, clinical palliation was attempted using stent re-insertion or PTBD. Clinical factors associated with T-configured dual stenting were examined in the patients with stent re-obstruction, which was followed by a correlation between these clinical factors and stent obstruction. Eleven of 13 patients were successfully treated by the unilobar approach. The two unsuccessful cases sustained angulation of the central large mesh stent. For the bilobar approach, 14 of 15 patients were successfully treated. For the one unsuccessful patient, the stent failed to pass through the central large mesh. Stent obstruction was revealed in 13 patients during the follow-up period. Balloon-assisted stent re-canalization was successfully performed in 5 patients. The analysis suggests that no definite correlation was found between stent obstruction and the clinical factors associated with dual stent placement. Conversely, bile containing sludge or debris was significantly correlated to early stent obstruction. Technical adoption considering the bile duct anatomy and obstruction pattern is important for T-configured dual stent implantation. The prudent evaluation of bile juice characters and cholangiographic findings is required for the appropriate clinical application of the T-configured dual stenting

  6. Optimal Trajectories Generation in Robotic Fiber Placement Systems

    Science.gov (United States)

    Gao, Jiuchun; Pashkevich, Anatol; Caro, Stéphane

    2017-06-01

    The paper proposes a methodology for optimal trajectories generation in robotic fiber placement systems. A strategy to tune the parameters of the optimization algorithm at hand is also introduced. The presented technique transforms the original continuous problem into a discrete one where the time-optimal motions are generated by using dynamic programming. The developed strategy for the optimization algorithm tuning allows essentially reducing the computing time and obtaining trajectories satisfying industrial constraints. Feasibilities and advantages of the proposed methodology are confirmed by an application example.

  7. Computer guided pre-operative planning and dental implant placement

    Directory of Open Access Journals (Sweden)

    Dušan Grošelj

    2007-05-01

    Full Text Available Background: Implants in dentistry are, besides fixed, removable and maxillofacial prosthodontics, one of the reliable possibility to make functional and aesthetic rehabilitation of the edentulism. Surgical and prosthodontic implant complications are often an inattentive consequence of wrong diagnosis, planning, and placement. In this article we present a technique using a highly advanced software program along with a rapid prototyping technology named stereolithography. A planning software for implant placement needs basically the high quality computed tomographic scan of one or both jaws for making accurate preoperative diagnostics and 3D preoperative plan. Later individual drill guide is designed and generated based on both the CT images and the preoperative planning. The patient specific drill guide transfers the virtual planning to the patient’s mouth at time of surgery.Conclusions: The advantages of computer guided implantology are the better prepared surgery with visualisation of critical anatomic structures, assessment of available bone and data about bone quality, increased confidence for the surgeon, deceased operative time, less frequent use of bone grafts, higher quality of collaboration between specialists and prosthetic lab and better communication with patients. Radiographic examination of the operation field for computer guided planning for implant placement is due to high costs justified as the most important information source on the areas to be implanted.

  8. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  9. Treatment of malignant central airway obstruction with Y-type metallic stent placement under general anaesthesia

    International Nuclear Information System (INIS)

    Yang Zhengqiang; Shi Haibin; Zhou Weizhong; Leng Derong; Li Linsun

    2010-01-01

    Objective: To report the clinical experience in treating malignant central airway obstruction with the placement of a domestic Y-shaped stent under general anaesthesia. Methods: The placement of a domestic Y-stent under general anaesthesia together with tracheal intubation was performed in three male patients of central lung cancer with the involvement of carina and subsequent malignant airway stenosis. The combination of Y-stent delivering and tracheal intubation had not been reported in the literature so far, so the technical experience was introduced in this paper. Results: The placement of Y-stent was successfully completed in all 3 patients. The whole procedure was smoothly carried out with no severe complications. After the operation the dyspnea was markedly relieved in all the patients. Conclusion: As a safe and effective treatment for malignant central airway obstructions, the placement of a domestic Y-stent under general anaesthesia can reduce patient's discomfort during the stent delivering process. A large cohort of patients is required in order to evaluate the long-term efficacy and related complications of this technique. (authors)

  10. Planned and unplanned terminations of foster care placements in the Netherlands: Relationships with characteristics of foster children and foster placements

    NARCIS (Netherlands)

    van Rooij, F.; Maaskant, A.; Weijers, I.; Weijers, D.; Hermanns, J.

    2015-01-01

    This study examined the role of placement and child characteristics in the unplanned termination of foster placements. Data were used from 169 foster children aged 0 to 20. Results showed that 35% of all foster placement terminations were unplanned. Outcomes of logistic regression analyses

  11. Raman probes based on optically-poled double-clad fiber and coupler

    DEFF Research Database (Denmark)

    Brunetti, Anna Chiara; Margulis, Walter; Rottwitt, Karsten

    2012-01-01

    of a sample of dimethyl sulfoxide (DMSO), when illuminating the waveguide with 1064nm laser light. The Raman signal is collected in the inner cladding, from which it is retrieved with either a bulk dichroic mirror or a double-clad fiber coupler. The coupler allows for a substantial reduction of the fiber......Two fiber Raman probes are presented, one based on an optically-poled double-clad fiber and the second based on an optically-poled double-clad fiber coupler respectively. Optical poling of the core of the fiber allows for the generation of enough 532nm light to perform Raman spectroscopy...

  12. A Cognitive Model of College Mathematics Placement

    Science.gov (United States)

    1989-08-01

    study focused on the precalculus -- calculus placement decision. The Cognitive model uses novel, or analysis level, placement test items in an attempt to...relative to the requirements of a precalculus course. Placement test scores may be partitioned to give analysis and non-analysis subtest scores which can...67 5.1.1 1989 Intercorrelations ....................................................................... 67 5.1.2 1989 Precalculus -Calculus

  13. Seasonal Evolution of Titan's Stratosphere Near the Poles

    Science.gov (United States)

    Coustenis, A.; Jennings, D. E.; Achterberg, R. K.; Bampasidis, G.; Nixon, C. A.; Lavvas, P.; Cottini, V.; Flasar, F. M.

    2018-02-01

    In this Letter, we report the monitoring of seasonal evolution near Titan’s poles. We find Titan’s south pole to exhibit since 2010 a strong temperature decrease and a dramatic enhancement of several trace species such as complex hydrocarbons and nitriles (HC3N and C6H6 in particular) previously only observed at high northern latitudes. This results from the seasonal change on Titan going from winter (2002) to summer (2017) in the north and, at the same time, the onset of winter in the south pole. During this transition period atmospheric components with longer chemical lifetimes linger in the north, undergoing slow photochemical destruction, while those with shorter lifetimes decrease and reappear in the south. An opposite effect was expected in the north, but not observed with certainty until now. We present here an analysis of high-resolution nadir spectra acquired by Cassini/Cassini Composite Infrared Spectrometer in the past years and describe the temperature and composition variations near Titan’s poles. From 2013 until 2016, the northern polar region has shown a temperature increase of 10 K, while the south has shown a more significant decrease (up to 25 K) in a similar period of time. While the south polar region has been continuously enhanced since about 2012, the chemical content in the north is finally showing a clear depletion for most molecules only since 2015. This is indicative of a non-symmetrical response to the seasons in Titan’s stratosphere that can set constraints on photochemical and GCM models.

  14. Second-harmonic scanning optical microscopy of poled silica waveguides

    DEFF Research Database (Denmark)

    Pedersen, Kjeld; Bozhevolnyi, Sergey I.; Arentoft, Jesper

    2000-01-01

    Second-harmonic scanning optical microscopy (SHSOM) is performed on electric-field poled silica-based waveguides. Two operation modes of SHSOM are considered. Oblique transmission reflection and normal reflection modes are used to image the spatial distribution of nonlinear susceptibilities...... and limitations of the two operation modes when used for SHSOM studies of poled silica-based waveguides are discussed. The influence of surface defects on the resulting second-harmonic images is also considered. ©2000 American Institute of Physics....

  15. The benefits of a 5-day dysphagia intensive placement

    OpenAIRE

    Cocks, N.; Harding, C.; Pritchard, M.

    2014-01-01

    Finding practical dysphagia opportunities for students pre-qualification is challenging. Discussions with clinicians led to the development of a new placement model. The placement was just five days and had an accompanying workbook. The current study aimed to evaluate the benefits of the placement. Data were analysed from 40 students who attended an adult dysphagia placement and 13 who attended a paediatric dysphagia placement. Measures included a pre and post self-rating questionnaire, quali...

  16. Biomechanical analysis of double poling in elite cross-country skiers.

    Science.gov (United States)

    Holmberg, Hans-Christer; Lindinger, Stefan; Stöggl, Thomas; Eitzlmair, Erich; Müller, Erich

    2005-05-01

    To further the understanding of double poling (DP) through biomechanical analysis of upper and lower body movements during DP in cross-country (XC) skiing at racing speed. Eleven elite XC skiers performed DP at 85% of their maximal DP velocity (V85%) during roller skiing at 1 degrees inclination on a treadmill. Pole and plantar ground reaction forces, joint angles (elbow, hip, knee, and ankle), cycle characteristics, and electromyography (EMG) of upper and lower body muscles were analyzed. 1) Pole force pattern with initial impact force peak and the following active force peak (PPF) correlated to V85%, (r = 0.66, P biomechanical aspects. Future research should further investigate the relationship between biomechanical and physiological variables and elaborate training models to improve DP performance.

  17. Non-uniformly sampled grids in double pole coordinate system for freeform reflector construction

    Science.gov (United States)

    Ma, Donglin; Pacheco, Shaun; Feng, Zexin; Liang, Rongguang

    2015-08-01

    We propose a new method to design freeform reflectors by nonuniformly sampling the source intensity distribution in double pole coordinate system. In double pole coordinate system, there is no pole for the whole hemisphere because both poles of the spherical coordinate system are moved to southernmost point of the sphere and overlapped together. With symmetric definition of both angular coordinates in the modified double pole coordinate system, a better match between the source intensity distribution and target irradiance distribution can be achieved for reflectors with large acceptance solid angle, leading to higher light efficiency and better uniformity on the target surface. With non-uniform sampling of the source intensity, we can design circular freeform reflector to obtain uniform rectangular illumination pattern. Aided by the feedback optimization, the freeform reflector can achieve the collection efficiency for ideal point source over 0.7 and relative standard deviation (RSD) less than 0.1.

  18. Conceptual design of a three-pole wiggler for the APS upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Abliz, M., E-mail: mabliz@aps.anl.gov; Grimmer, J., E-mail: grimmer@aps.anl.gov; Dejus, R.; Ramanathan, M., E-mail: mohan@aps.anl.gov [The Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2016-07-27

    The current design of the Advanced Photon Source Upgrade (APS-U) project is a multi-bend achromat (MBA) lattice, which incorporates three-pole wigglers as radiation sources for the bending magnet beamlines. They are located in the short section between the M4 dipole and Q8 quadrupole magnets. Due to space constraints, a hybrid permanent magnet design is necessary to provide the required magnetic field strength. A three-pole wiggler with a flat peak field profile along the beam axis was designed to enhance the photon flux and flatten the transverse flux density distributions. The magnetic peak field at the center pole reached 1.08 Tesla for a magnetic gap of 26 mm. The maximum power density, integrated over all vertical angles, is 3.1 W/mm{sup 2}, which is substantially higher than that of the existing bending magnets at the APS (0.86 W/mm{sup 2}). Detailed designs of the three-pole wiggler is presented, including calculated spectral-angular flux distributions.

  19. Revised paleomagnetic pole for the Sonoma Volcanics, California

    Science.gov (United States)

    Mankinen, E.A.

    1989-01-01

    Paleomagnetic sampling of the Miocene and Pliocene Sonoma Volcanics, northern California, was undertaken to supplement an earlier collection. Data from 25 cooling units yield positive fold and reversal tests, and a paleomagnetic pole located at 80.2??N., 069.2??E., with ??95 = 6.8??. This paleopole is significantly displaced (9.6?? ?? 5.3?? of latitude) to the farside of the geographic pole. A highly elliptical distribution of the data in both direction and VGP space indicates that incomplete averaging of geomagnetic secular variation is a more likely explanation for this anomaly than is northward translation of the volcanic field. -Author

  20. Optimal DG placement in deregulated electricity market

    International Nuclear Information System (INIS)

    Gautam, Durga; Mithulananthan, Nadarajah

    2007-01-01

    This paper presents two new methodologies for optimal placement of distributed generation (DG) in an optimal power flow (OPF) based wholesale electricity market. DG is assumed to participate in real time wholesale electricity market. The problem of optimal placement, including size, is formulated for two different objectives, namely, social welfare maximization and profit maximization. The candidate locations for DG placement are identified on the basis of locational marginal price (LMP). Obtained as lagrangian multiplier associated with active power flow equation for each node, LMP gives the short run marginal cost (SRMC) of electricity. Consumer payment, evaluated as a product of LMP and load at each load bus, is proposed as another ranking to identify candidate nodes for DG placement. The proposed rankings bridges engineering aspects of system operation and economic aspects of market operation and act as good indicators for the placement of DG, especially in a market environment. In order to provide a scenario of variety of DGs available in the market, several cost characteristics are assumed. For each DG cost characteristic, an optimal placement and size is identified for each of the objectives. The proposed methodology is tested in a modified IEEE 14 bus test system. (author)

  1. Recent advances in poled optical fibres

    DEFF Research Database (Denmark)

    Pruneri, V.; Margulis, W.; Myrén, N.

    2005-01-01

    A second-order nonlinearity can be induced in optical fibres through poling. We describe accomplishments of the EU project GLAMOROUS in making low-cost high performance electrooptic and nonlinear optical fibre- and waveguide-based components. In particular a comparison with more traditional...

  2. Pole-to-pole biogeography of surface and deep marine bacterial communities

    Science.gov (United States)

    Ghiglione, Jean-François; Galand, Pierre E.; Pommier, Thomas; Pedrós-Alió, Carlos; Maas, Elizabeth W.; Bakker, Kevin; Bertilson, Stefan; Kirchman, David L.; Lovejoy, Connie; Yager, Patricia L.; Murray, Alison E.

    2012-01-01

    The Antarctic and Arctic regions offer a unique opportunity to test factors shaping biogeography of marine microbial communities because these regions are geographically far apart, yet share similar selection pressures. Here, we report a comprehensive comparison of bacterioplankton diversity between polar oceans, using standardized methods for pyrosequencing the V6 region of the small subunit ribosomal (SSU) rRNA gene. Bacterial communities from lower latitude oceans were included, providing a global perspective. A clear difference between Southern and Arctic Ocean surface communities was evident, with 78% of operational taxonomic units (OTUs) unique to the Southern Ocean and 70% unique to the Arctic Ocean. Although polar ocean bacterial communities were more similar to each other than to lower latitude pelagic communities, analyses of depths, seasons, and coastal vs. open waters, the Southern and Arctic Ocean bacterioplankton communities consistently clustered separately from each other. Coastal surface Southern and Arctic Ocean communities were more dissimilar from their respective open ocean communities. In contrast, deep ocean communities differed less between poles and lower latitude deep waters and displayed different diversity patterns compared with the surface. In addition, estimated diversity (Chao1) for surface and deep communities did not correlate significantly with latitude or temperature. Our results suggest differences in environmental conditions at the poles and different selection mechanisms controlling surface and deep ocean community structure and diversity. Surface bacterioplankton may be subjected to more short-term, variable conditions, whereas deep communities appear to be structured by longer water-mass residence time and connectivity through ocean circulation. PMID:23045668

  3. Product Placement and Brand Equity

    OpenAIRE

    Corniani, Margherita

    2003-01-01

    Product placement is the planned insertion of a brand within a movie, a fiction, etc. It can be used with other communication tools (i.e. advertising, sales promotions, etc.) in order to disseminate brand awareness and characterize brand image, developing brand equity. In global markets, product placement is particularly useful for improving brand equity of brands with a well established brand awareness.

  4. All-Pole Recursive Digital Filters Design Based on Ultraspherical Polynomials

    Directory of Open Access Journals (Sweden)

    N. Stojanovic

    2014-09-01

    Full Text Available A simple method for approximation of all-pole recursive digital filters, directly in digital domain, is described. Transfer function of these filters, referred to as Ultraspherical filters, is controlled by order of the Ultraspherical polynomial, nu. Parameter nu, restricted to be a nonnegative real number (nu ≥ 0, controls ripple peaks in the passband of the magnitude response and enables a trade-off between the passband loss and the group delay response of the resulting filter. Chebyshev filters of the first and of the second kind, and also Legendre and Butterworth filters are shown to be special cases of these allpole recursive digital filters. Closed form equations for the computation of the filter coefficients are provided. The design technique is illustrated with examples.

  5. Raman Probe Based on Optically-Poled Double-Core Fiber

    DEFF Research Database (Denmark)

    Brunetti, Anna Chiara; Margulis, Walter; Rottwitt, Karsten

    2012-01-01

    A Raman probe based on an optically-poled double-core fiber. In-fiber SHG allows for Raman spectroscopy of DMSO at 532nm when illuminating the fiber with 1064nm light. The fiber structure provides independent excitation and collection paths.......A Raman probe based on an optically-poled double-core fiber. In-fiber SHG allows for Raman spectroscopy of DMSO at 532nm when illuminating the fiber with 1064nm light. The fiber structure provides independent excitation and collection paths....

  6. Inferior patellar pole fragmentation in children: just a normal variant?

    Energy Technology Data Exchange (ETDEWEB)

    Kan, J.H.; Vogelius, Esben S.; Orth, Robert C.; Guillerman, R.P.; Jadhav, Siddharth P. [Texas Children' s Hospital, E.B. Singleton Pediatric Radiology, Houston, TX (United States)

    2015-06-15

    Fragmentary ossification of the inferior patella is often dismissed as a normal variant in children younger than 10 years of age. The purpose of this study was to determine whether fragmentary inferior patellar pole ossification is a normal variant or is associated with symptoms or signs of pathology using MRI and clinical exam findings as reference. A retrospective review was performed on 150 patients ages 5-10 years who underwent 164 knee radiography and MRI exams (45.1% male, mean age: 7.8 years). The presence or absence of inferior patellar pole fragmentation on radiography was correlated with the presence or absence of edema-like signal on MR images. Clinical notes were reviewed for the presence of symptoms or signs referable to the inferior patellar pole. These data were compared with a 1:1 age- and sex-matched control group without inferior pole fragmentation. Statistical analysis was performed using two-tailed t-tests. Forty of 164 (24.4%) knee radiographs showed fragmentary ossification of the inferior patella. Of these 40 knees, 62.5% (25/40) had edema-like signal of the inferior patellar bone marrow compared with 7.5% (3/40) of controls (P = 0.035). Patients with fragmentary ossification at the inferior patella had a significantly higher incidence of documented focal inferior patellar pain compared with controls (20% vs. 2.5%, P = 0.015). Inferior patellar pole fragmentation in children 5 to 10 years of age may be associated with localized symptoms and bone marrow edema-like signal and should not be routinely dismissed as a normal variant of ossification. (orig.)

  7. Relation between bottom-quark MS Yukawa coupling and pole mass

    International Nuclear Information System (INIS)

    Kniehl, B.A.; Piclum, J.H.; Steinhauser, M.

    2004-04-01

    We calculate the O (αα s ) corrections to the relationships between the MS Yukawa couplings and the pole masses of the first five quark flavours in the standard model. We also present the corresponding relationships between the MS and pole masses, which emerge as by-products of our main analysis. The occurring self-energies are evaluated using the method of asymptotic expansion. (orig.)

  8. PEG Tube Placement

    Directory of Open Access Journals (Sweden)

    Saptarshi Biswas

    2014-01-01

    Full Text Available Percutaneous endoscopic gastrostomy (PEG has been used for providing enteral access to patients who require long-term enteral nutrition for years. Although generally considered safe, PEG tube placement can be associated with many immediate and delayed complications. Buried bumper syndrome (BBS is one of the uncommon and late complications of percutaneous endoscopic gastrostomy (PEG placement. It occurs when the internal bumper of the PEG tube erodes into the gastric wall and lodges itself between the gastric wall and skin. This can lead to a variety of additional complications such as wound infection, peritonitis, and necrotizing fasciitis. We present here a case of buried bumper syndrome which caused extensive necrosis of the anterior abdominal wall.

  9. FEM Analysis of Brushless DC Servomotor with Fractional Number of Slots per Pole

    Directory of Open Access Journals (Sweden)

    BALUTA, G.

    2014-02-01

    Full Text Available The authors present in this paper the analysis with Finite Element Method (FEM of the magnetic circuit for a Brushless DC servomotor with fractional number of slots/pole (9 slots and 10 poles. For this purpose, FEMM 4.2 software package was used for the analysis. To obtain the waveforms of Back-ElectroMotive Forces (BEMFs, electromagnetic and cogging torque for servomotor a program in LUA scripting language (integrated into interactive shell of FEMM4.2 has been created. A comparation with a structure with integer number of slots/pole (18 slots and 6 poles was also realized. The analysis results prove that the structure chosen is an optimal solution: sinusoidal waveforms of BEMFs, improved electromagnetic torque and reduced cogging torque. Therefore, the operating characteristics of the servomotor with 9/10 slots/poles manufactured by Sistem Euroteh Company and included in an integrated electrical drives system are presented in this paper.

  10. A Visit to the South Pole

    Indian Academy of Sciences (India)

    IAS Admin

    For these reasons, I could not buy many of the essential things .... Geomagnetic South Pole at 78° 27' S, 106° 48' E at an altitude of 3,488 metres on approximately .... Smokers at the station were often found searching for used cigarette butts.

  11. Third Pole Environment (TPE): a new frontier for interdisciplinary research

    Science.gov (United States)

    Liu, Z.; Yao, T.; Thompson, L. G.; Mosbrugger, V.; Zhang, F.; Ma, Y.; Yang, X.; Wang, W.; Joswiak, D.; Liu, X.; Devkota, L. P.; Tayal, S.; Luo, T.

    2013-12-01

    The Tibetan Plateau and surrounding mountain ranges, referred to by scientists as the Third Pole (TP), represent one of the largest ice masses of the Earth. The region is one of the most sensitive areas responding to global climate change due to its high altitude and the presence of permafrost and glaciers. The near 100,000 km2 of glaciers ensure the permanent flow of major rivers in this region and provide water to 1.4 billion people in Asia. Thus, environmental changes taking place on the TP significantly influences social and economic development of countries in this region such as China, India, Nepal, Tajikistan, Pakistan, Afghanistan and Bhutan. With an average elevation higher than 4,000 metres above sea level, the Third Pole is characterized by complex interactions of atmospheric, cryospheric, hydrological, geological and environmental processes that bear special significance for the Earth's biodiversity, climate and water cycles. For a comprehensive understanding of the environment of the TP and its implications on the development of the region, we need to integrate different disciplines under a them of 'water-ice-air-ecosystem -human' interactions and reveal environmental change processes and mechanisms on the TP and their influences on and regional responses to global changes, and thus to serve for enhancement of human adaptation to the changing environment. Like Antarctica and the Arctic, the Third Pole region is drawing increased attention of the international academic community. A series of observations and monitoring programs in the Third Pole region has been widely implemented. However, data necessary to precisely assess the environmental, societal and economic changes caused by alterations in the Third Pole dynamics are either lacking or insufficient. The Third Pole Environment (TPE) program is thus established as a comprehensive and coordinated international research, monitoring and capacity building initiative, with goals to address the influence

  12. Asteroid (16) Psyche: Triaxial Ellipsoid Dimensions and Rotational Pole from Keck II NIRC2 AO Images and Keck I OSIRIS Images

    Science.gov (United States)

    Drummond, Jack D.; Conrad, Al; Reddy, Vishnu; de Kleer, Katherine R.; Adamkovics, Mate; de Pater, Imke; Merline, William J.; Tamblyn, Peter

    2016-10-01

    Adaptive optics (AO) images of asteroid (16) Psyche obtained at 4 epochs with the NIRC2 camera at the 10m W. M. Keck Observatory (Keck II) on UT 2015 December 25 lead to triaxial ellipsoid diameters of 279±4 x 230±2 x 195±14 km, and a rotational pole at RA=29° and Dec=-2°. Adding 6 more epochs obtained nearly simultaneously with the OSIRIS system at Keck I, as well as two more epochs from Keck II in 2009, yields diameters of 273±2 x 232±2 x 165±3 km, and a pole at RA=37° and Dec=+1°. (Errors are formal fit parameter uncertainties; an additional 4% uncertainty is possible from systematic biases.) The differing perspectives between 2015 (sub-Earth latitude Θ=-50°) and 2009 (Θ=-6°) improves primarily the c dimension and the location of the rotational pole, but illustrates how well images from even a single night can determine the size, shape, and pole of an asteroid. The 2015 observations were obtained as part of a campaign to study Psyche with many techniques over a few months, including radar from Arecibo and images from Magellan.These handful of images show the same rugged outline as the radius vector model available on the DAMIT website, constructed from many lightcurves and scaled by previous Keck AO images. In fact Psyche has rotated some 125,350 times between the first lightcurve in 1955 and our 2015 AO images, exactly 60 years apart to the day. Since the asteroid has such a high obliquity, these lightcurves have scanned well into both northern and southern hemispheres. The difference between the pole derived from our images and the radius vector model pole is only 7°, and the mean diameters of Psyche are 219 and 211 km, respectively.

  13. PLANNING THE QUALITY OF LIFE FOR TIMISOARA GROWTH POLE

    Directory of Open Access Journals (Sweden)

    Cătălina-Livia POPA

    2014-06-01

    Full Text Available This paper aims to show that planning the quality of life at local level through economic development can be a new approach for policy makers and community in improving quality of life. In this purpose, the Quality Function Deployment (QFD model will be use to planning the quality of life and to identify the main directions of economic development to support improving the quality of life at the level of Timisoara Growth Pole from Romania. The dimensions of quality of life are analyzed starting from the point of view of inhabitants. The results include a new approach in which the dimensions of quality of life are the key element that orients economic development in order to improve the quality of life of human being. The case study results refer to the main elements of quality of life at Timisoara Growth Pole and the relevant directions of economic development to improve the quality of life for Timisoara Growth Pole.

  14. Dental hygiene student experiences in external placements in Australia.

    Science.gov (United States)

    Taylor, Jane A; Hayes, Melanie J; Wallace, Linda

    2012-05-01

    While placements in external locations are being increasingly used in dental education globally, few studies have explored the student learning experience at such placements. The purpose of this study was to investigate student experiences while on external placement in a baccalaureate dental hygiene program. A self-reporting questionnaire was distributed to final-year dental hygiene students (n=77) at the University of Newcastle, Australia, in 2010. The questionnaire included questions regarding the type of placement, experiences offered, supervision, resources available, and lasting impressions. Responding students were generally positive about their external placement experience and indicated that the majority of facilities provided them with the opportunity to provide direct patient care and perform clinical tasks typical of a practicing hygienist. However, there was a statistically significant difference in their opinions about discipline-focused and community placements. Students indicated that their external placement experience provided opportunities to learn more about time and patient management, including hands-on experience with specific clinical tasks. Ongoing evaluations are necessary to ensure that external placements meet both student needs and intended learning outcomes within dental hygiene programs.

  15. Fault Current Distribution and Pole Earth Potential Rise (EPR) Under Substation Fault

    Science.gov (United States)

    Nnassereddine, M.; Rizk, J.; Hellany, A.; Nagrial, M.

    2013-09-01

    New high-voltage (HV) substations are fed by transmission lines. The position of these lines necessitates earthing design to ensure safety compliance of the system. Conductive structures such as steel or concrete poles are widely used in HV transmission mains. The earth potential rise (EPR) generated by a fault at the substation could result in an unsafe condition. This article discusses EPR based on substation fault. The pole EPR assessment under substation fault is assessed with and without mutual impedance consideration. Split factor determination with and without the mutual impedance of the line is also discussed. Furthermore, a simplified formula to compute the pole grid current under substation fault is included. Also, it includes the introduction of the n factor which determines the number of poles that required earthing assessments under substation fault. A case study is shown.

  16. 25 CFR 26.27 - What kind of Job Placement support services can I expect?

    Science.gov (United States)

    2010-04-01

    ... resume preparation, interview techniques, job retention, and related living skills. ... 25 Indians 1 2010-04-01 2010-04-01 false What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB...

  17. Improved technology for spun-cast concrete poles

    Energy Technology Data Exchange (ETDEWEB)

    Dilger, W H; Ghali, A

    1984-07-01

    Different types of concrete were investigated with the goal of developing concrete suitable for the production of spun-cast concrete poles. A total of 65 different concrete mixes were investigated, with the suitability criteria defined as: compactability, no segregation of the mix components during the spinning operation, no shrinkage cracking, high strength, and durability. High strength normal weight concretes and semi-lightweight concretes, both with and without fly ash and/or silica fume and with different types of admixtures were used to produce spun-cast concrete pole segments. Of the 35 lightweight concretes only 3 were considered successful, as in all other specimens the inner layer of coarse aggregate was not well embedded in the mortar, and many mixes could not be compacted properly because they were too stiff, too wet, or started to set before spinning commenced. The three successful specimens contained fly ash and one contained silica fume, and had low water/cement ratios (0.26 to 0.29). Of the 23 normal weight concretes tested, only 5 were considered suitable, and all these had a sand/coarse aggregate ratio of 0.25 or smaller and a cement content between 350 and 400 kg/m{sup 3}. A theoretical study of the stresses in the end zones of pretensioned poles is presented. 10 refs., 53 figs., 14 tabs.

  18. The South Pole and the Ross Sea

    Science.gov (United States)

    2002-01-01

    This image shows a rare clear view of the South Pole (lower right) and the Ross Sea, Antarctica. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) acquired the scene on December 26, 2001. The geographic South Pole is located in the center of Antarctica, at an altitude of 2,900 meters (9,300 feet). It rests on a continent-wide ice sheet that is 2,870 m thick, with the underlying bedrock only 30 m (98 feet) above sea level. The ice underlying the South Pole is as much as 140,000 years old, and is currently accumulating at about 82 cm (32 inches) per year. Roughly 2,500 km (1,550 miles) away is the green water of the Ross Sea, which indicates the presence of large numbers of phytoplankton. This is a highly productive part of the world's oceans. Also note the ice gathered around McMurdo Sound, seen toward the lefthand shoreline of the Ross Sea, at the edge of the Ross Ice Shelf. According to National Science Foundation researchers, this ice is making it difficult for penguins to reach their food supply. Separating the continental Antarctic ice sheet from the Ross Sea are the Queen Maud Mountains and the Ross Ice Shelf. Image courtesy the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  19. Risk Management in the Original Extreme Sporting Event: The Pole Vault

    Science.gov (United States)

    Bemiller, Jim; Hardin, Robin

    2010-01-01

    The pole vault was considered the ultimate test of physical ability and daring before the advent of modern extreme sports such as skateboarding, snowboarding, and mountain biking. The inherent risks of the pole vault have been well documented. The National Center for Catastrophic Sport Injury Research reported in 2007 that the catastrophic injury…

  20. THE SUSTAINABLE DEVELOPMENT OF THE BRASOV GROWTH POLE

    Directory of Open Access Journals (Sweden)

    Aida CATANA

    2016-12-01

    Full Text Available The demographic dynamics analysed in the context of the relationship between economic development and social inclusion presents an image of the sustainable development of a community as well as the manner how the financial resources have been used. With an allocation of 74.3 million euro in the programming period 2007-2013, the Brasov Growth Pole has pursued the contribution to the achievement of sustainable development since 2005 by the participation in the Agenda 21. The implementation of projects with European financing in areas such as transport, social and educational infrastructure or tourism have generated changes/demographic movements, which this paper proposes to present. The evolution of the stable population, its dynamics at the level of each locality that is part of the Brasov growth pole as well as the dynamics of the number of employees or the development of the unemployment rate are presented by the cluster analysis. The effects of the European financing obtained from Regional Operational Programme 2007-2013 are thus reflected in the sustainable development of the Brasov growth pole from the point of view of the dynamics of the population

  1. Frequent POLE1 p.S297F mutation in Chinese patients with ovarian endometrioid carcinoma

    International Nuclear Information System (INIS)

    Zou, Yang; Liu, Fa-Ying; Liu, Huai; Wang, Feng; Li, Wei; Huang, Mei-Zhen; Huang, Yan; Yuan, Xiao-Qun; Xu, Xiao-Yun; Huang, Ou-Ping; He, Ming

    2014-01-01

    The catalytic subunit of DNA polymerase epsilon (POLE1) functions primarily in nuclear DNA replication and repair. Recently, POLE1 mutations were detected frequently in colorectal and endometrial carcinomas while with lower frequency in several other types of cancer, and the p.P286R and p.V411L mutations were the potential mutation hotspots in human cancers. Nevertheless, the mutation frequency of POLE1 in ovarian cancer still remains largely unknown. Here, we screened a total of 251 Chinese samples with distinct subtypes of ovarian carcinoma for the presence of POLE1 hotspot mutations by direct sequencing. A heterozygous somatic POLE1 mutation, p.S297F (c.890C>T), but not p.P286R and p.V411L hotspot mutations observed in other cancer types, was identified in 3 out of 37 (8.1%) patients with ovarian endometrioid carcinoma; this mutation was evolutionarily highly conserved from Homo sapiens to Schizosaccharomyces. Of note, the POLE1 mutation coexisted with mutation in the ovarian cancer-associated PPP2R1A (protein phosphatase 2, regulatory subunit A, α) gene in a 46-year-old patient, who was also diagnosed with ectopic endometriosis in the benign ovary. In addition, a 45-year-old POLE1-mutated ovarian endometrioid carcinoma patient was also diagnosed with uterine leiomyoma while the remaining 52-year-old POLE1-mutated patient showed no additional distinctive clinical manifestation. In contrast to high frequency of POLE1 mutations in ovarian endometrioid carcinoma, no POLE1 mutations were identified in patients with other subtypes of ovarian carcinoma. Our results showed for the first time that the POLE1 p.S297F mutation, but not p.P286R and p.V411L hotspot mutations observed in other cancer types, was frequent in Chinese ovarian endometrioid carcinoma, but absent in other subtypes of ovarian carcinoma. These results implicated that POLE1 p.S297F mutation might be actively involved in the pathogenesis of ovarian endometrioid carcinoma, but might not be actively

  2. Frequent POLE1 p.S297F mutation in Chinese patients with ovarian endometrioid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Yang; Liu, Fa-Ying; Liu, Huai; Wang, Feng [Key Laboratory of Women' s Reproductive Health of Jiangxi Province, Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi 330006 (China); Central Laboratory, Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi 330006 (China); Li, Wei [Key Laboratory of Women' s Reproductive Health of Jiangxi Province, Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi 330006 (China); Central Laboratory, Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi 330006 (China); Graduate School of Nanchang University, Nanchang, Jiangxi 330031 (China); Huang, Mei-Zhen [Graduate School of Nanchang University, Nanchang, Jiangxi 330031 (China); Jiangxi Provincial Cancer Institute, Jiangxi Provincial Cancer Hospital, Nanchang, Jiangxi 330029 (China); Huang, Yan; Yuan, Xiao-Qun [Key Laboratory of Women' s Reproductive Health of Jiangxi Province, Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi 330006 (China); Central Laboratory, Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi 330006 (China); Graduate School of Nanchang University, Nanchang, Jiangxi 330031 (China); Xu, Xiao-Yun [Graduate School of Nanchang University, Nanchang, Jiangxi 330031 (China); Jiangxi Provincial Cancer Institute, Jiangxi Provincial Cancer Hospital, Nanchang, Jiangxi 330029 (China); Huang, Ou-Ping, E-mail: huangouping@gmail.com [Jiangxi Provincial Cancer Institute, Jiangxi Provincial Cancer Hospital, Nanchang, Jiangxi 330029 (China); He, Ming, E-mail: jxhm56@hotmail.com [Department of Pharmacology and Molecular Therapeutics, Nanchang University School of Pharmaceutical Science, Nanchang 330006 (China)

    2014-03-15

    The catalytic subunit of DNA polymerase epsilon (POLE1) functions primarily in nuclear DNA replication and repair. Recently, POLE1 mutations were detected frequently in colorectal and endometrial carcinomas while with lower frequency in several other types of cancer, and the p.P286R and p.V411L mutations were the potential mutation hotspots in human cancers. Nevertheless, the mutation frequency of POLE1 in ovarian cancer still remains largely unknown. Here, we screened a total of 251 Chinese samples with distinct subtypes of ovarian carcinoma for the presence of POLE1 hotspot mutations by direct sequencing. A heterozygous somatic POLE1 mutation, p.S297F (c.890C>T), but not p.P286R and p.V411L hotspot mutations observed in other cancer types, was identified in 3 out of 37 (8.1%) patients with ovarian endometrioid carcinoma; this mutation was evolutionarily highly conserved from Homo sapiens to Schizosaccharomyces. Of note, the POLE1 mutation coexisted with mutation in the ovarian cancer-associated PPP2R1A (protein phosphatase 2, regulatory subunit A, α) gene in a 46-year-old patient, who was also diagnosed with ectopic endometriosis in the benign ovary. In addition, a 45-year-old POLE1-mutated ovarian endometrioid carcinoma patient was also diagnosed with uterine leiomyoma while the remaining 52-year-old POLE1-mutated patient showed no additional distinctive clinical manifestation. In contrast to high frequency of POLE1 mutations in ovarian endometrioid carcinoma, no POLE1 mutations were identified in patients with other subtypes of ovarian carcinoma. Our results showed for the first time that the POLE1 p.S297F mutation, but not p.P286R and p.V411L hotspot mutations observed in other cancer types, was frequent in Chinese ovarian endometrioid carcinoma, but absent in other subtypes of ovarian carcinoma. These results implicated that POLE1 p.S297F mutation might be actively involved in the pathogenesis of ovarian endometrioid carcinoma, but might not be actively

  3. Finite element modeling of small-scale tapered wood-laminated composite poles with biomimicry features

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse

    2008-01-01

    Tapered composite poles with biomimicry features as in bamboo are a new generation of wood laminated composite poles that may some day be considered as an alternative to solid wood poles that are widely used in the transmission and telecommunication fields. Five finite element models were developed with ANSYS to predict and assess the performance of five types of...

  4. A linear programming approach for placement of applicants to academic programs.

    Science.gov (United States)

    Kassa, Biniyam Asmare

    2013-01-01

    This paper reports a linear programming approach for placement of applicants to study programs developed and implemented at the college of Business & Economics, Bahir Dar University, Bahir Dar, Ethiopia. The approach is estimated to significantly streamline the placement decision process at the college by reducing required man hour as well as the time it takes to announce placement decisions. Compared to the previous manual system where only one or two placement criteria were considered, the new approach allows the college's management to easily incorporate additional placement criteria, if needed. Comparison of our approach against manually constructed placement decisions based on actual data for the 2012/13 academic year suggested that about 93 percent of the placements from our model concur with the actual placement decisions. For the remaining 7 percent of placements, however, the actual placements made by the manual system display inconsistencies of decisions judged against the very criteria intended to guide placement decisions by the college's program management office. Overall, the new approach proves to be a significant improvement over the manual system in terms of efficiency of the placement process and the quality of placement decisions.

  5. Immediate placement of endosseous implants into the extraction sockets.

    Science.gov (United States)

    Ebenezer, Vijay; Balakrishnan, K; Asir, R Vigil Dev; Sragunar, Banu

    2015-04-01

    Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by "why late when it can be done immediately." There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed.

  6. Experience on impregnation of wood.en poles with water borne salts

    African Journals Online (AJOL)

    I. Leechability. Since the process depends on osmosis, the preservative must be highly soluble in water and rains may wash it away. 2. Diminished Mechanical Strength. Pricking of the pole at and around the ground line will diminish the mechanical strength of the pole. 3. Cost. Most important of all, the cost of the preserva-.

  7. Vena cava filter placement via the antecubital access: a report of 6 cases

    International Nuclear Information System (INIS)

    Yu Bo; Shi Weihao; He Qing; Wang Tieping; Wang Wei

    2008-01-01

    Objective: To study the methods and skill of vena cava filter placement via the antecubital access. Methods: Six patients with DVT (4 males and 2 females, mean age of 62) underwent vena cava filter placement via the antecubital access in Huashan Hospital from Oct. 2004 to May. 2006. The right basilic vein was punctured with the use of micropuncture technique. SNF(Simon nitinol filter, Bard)was inserted through its carrier into the 90-cm-long sheath. The filter was then deployed with a standard fashion in the IVC, 5 cm inferior to the renal vein. Results: The filter was once placed successfully in all six patients within average time of 25 min without complications, but with good healing, exclusion of bleeding and no phlebitis. The position of filter was accurate without deviation and no occurrence of pulmonary embolism. Conclusions: vena cava filter placement via antecubital access is easy, minimal invasive, no need of lying in bed postoperatively. It is beneficial for DVT patients as an alternative for the contra-indication to femoral venous access. (authors)

  8. Spontaneous Temporal Pole Encephalocele Presenting with Epilepsy: Report of Two Cases.

    Science.gov (United States)

    Shimada, Seijiro; Kunii, Naoto; Kawai, Kensuke; Usami, Kenichi; Matsuo, Takeshi; Uno, Takeshi; Koizumi, Tomoyuki; Saito, Nobuhito

    2015-09-01

    Refractory temporal lobe epilepsy due to spontaneous temporal pole encephalocele is a rare but increasingly recognized condition. Optimal surgical management is complicated by the lack of knowledge regarding both the extent of the epileptogenic area and the need for repair of the encephalocele. We report two cases that add significant information to these issues. In Case 1, with a 5-year history of refractory seizures, implantation of diagnostic subdural electrodes into the anterior temporal base happened to abolish the seizures completely. No structural changes were evident on postoperative magnetic resonance imaging. In Case 2, with a large encephalocele and a 5-year history of refractory seizures, surgical disconnection of the temporal pole successfully abolished seizures without any need for encephalocele repair. These two cases support the view that the epileptogenic area is confined to within the temporal pole for spontaneous temporal pole encephalocele. Temporopolar disconnection represents one surgical option for this entity that achieves seizure cessation without requiring extra repair procedures. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    Science.gov (United States)

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  10. Lower Pole Calyceal Stone and Lithotripsy are Issues with Clearance Fact or Reality?

    Directory of Open Access Journals (Sweden)

    M. Hammad Ather

    2013-12-01

    Full Text Available The lower pole calyceal (LPC stone continues to be an enigma. The complex anatomy of the lower pole collecting system, along with other factors like acute pelvi calyceal angle and narrow and long infundibulum, are some of the complicating factors affecting stone clearance. There have been many studies assessing the impact of collecting system anatomy and most conclude that the complex anatomy of the lower pole collecting system does impact the overall stone-free rate.

  11. Nontraumatic osteonecrosis of the distal pole of the scaphoid

    Directory of Open Access Journals (Sweden)

    Bhavuk Garg

    2011-01-01

    Full Text Available Post traumatic osteonecrosis of distal pole of scaphoid is very rare. We present a case of 34 years old male, drill operator by occupation with nontraumatic osteonecrosis of distal pole of the scaphoid. The patient was managed conservatively and was kept under regular follow-up every three months. The patient was also asked to change his profession. Two years later, the patient had no pain and had mild restriction of wrist movements (less than 15 degrees in either direction. The radiographs revealed normal density of the scaphoid suggesting revascularization.

  12. Peculiarities of product placement in Lithuanian movies

    OpenAIRE

    Pilelienė, Lina; Jurgilaitė, Sigita

    2013-01-01

    The scientific problem analysed in the article is formulates as follows: how product placement is used in Lithuanian movies. The object of the article is product placement in Lithuanian movies, and the aim is to analyse the peculiarities of product placement in Lithuanian movies. Following methods were used to reveal the problem and reach the aim. Theoretical analysis of scientific literature was provided to construct the framework for the research. The analysis of current usage of product pl...

  13. Pole counting and resonance classification

    International Nuclear Information System (INIS)

    Morgan, D.

    1992-01-01

    S-wave resonances occurring close to an inelastic threshold can be classified according to the number of nearby poles they possess. One then has a useful possibility of distinguishing dynamical alternatives by objective appeal to data. Making this quantitative entails developing suitable effective range expansions for various realizations of potential scattering. A key application is deciding the make-up of f 0 (976) (S*). (author)

  14. Textured dysprosium and gadolinium poles for high-field, short-period hybrid undulators

    International Nuclear Information System (INIS)

    Murokh, Alex; Solovyov, Vyacheslav; Agustsson, Ron; O'Shea, Finn H.; Chubar, Oleg; Chen, Yung; Grandsaert, Thomas

    2014-01-01

    We discuss the feasibility of enhancement of the gap field in a short-period hybrid undulator by using pole inserts with the saturation inductance B s , over that of iron, 2 T. Dysprosium metal, with the saturation inductance of 3.4 T below 90 K, and Gadolinium with B s =2.7 T, appear as good candidates as the optimized pole material. However, due to the high magnetic anisotropy of Dy, such a high level of magnetization can only be realized when the external field lies in the basal plane. This implies that the pole has to be single-crystalline or highly textured. Considering that growing large, >10mm, Dy single crystals is difficult, we propose secondary recrystallization as a method to induce the required texture in thin Dy and Gd foils. The textured foils can be stacked to produce pole inserts of the desired geometry and orientation. Results of small-scale processing and magnetic measurements of thin (20–60 μ) foils provide evidence that the required texture quality can be achieved by a relatively simple sequence of heat-treatments and cold rolling. The advantage of textured Dy and Gd poles is demonstrated in a several period test undulator. -- Highlights: • Textured rare-earth materials for use as undulator pole materials. • We measure the development of texture in Dy and Gd. • We compare the rare-earth materials with high saturation steel in undulators. • Thin sheets of Dy and Gd materials perform similar to single crystals

  15. Immediate placement of endosseous implants into the extraction sockets

    Directory of Open Access Journals (Sweden)

    Vijay Ebenezer

    2015-01-01

    Full Text Available Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by "why late when it can be done immediately." There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed.

  16. Multijet final states: exact results and the leading pole approximation

    International Nuclear Information System (INIS)

    Ellis, R.K.; Owens, J.F.

    1984-09-01

    Exact results for the process gg → ggg are compared with those obtained using the leading pole approximation. Regions of phase space where the approximation breaks down are discussed. A specific example relevant for background estimates to W boson production is presented. It is concluded that in this instance the leading pole approximation may underestimate the standard QCD background by more than a factor of two in certain kinematic regions of physical interest

  17. Optimal placement of capacito

    Directory of Open Access Journals (Sweden)

    N. Gnanasekaran

    2016-06-01

    Full Text Available Optimal size and location of shunt capacitors in the distribution system plays a significant role in minimizing the energy loss and the cost of reactive power compensation. This paper presents a new efficient technique to find optimal size and location of shunt capacitors with the objective of minimizing cost due to energy loss and reactive power compensation of distribution system. A new Shark Smell Optimization (SSO algorithm is proposed to solve the optimal capacitor placement problem satisfying the operating constraints. The SSO algorithm is a recently developed metaheuristic optimization algorithm conceptualized using the shark’s hunting ability. It uses a momentum incorporated gradient search and a rotational movement based local search for optimization. To demonstrate the applicability of proposed method, it is tested on IEEE 34-bus and 118-bus radial distribution systems. The simulation results obtained are compared with previous methods reported in the literature and found to be encouraging.

  18. Diagnosis of excessive vibration signals of two-pole generator rotors in balancing

    International Nuclear Information System (INIS)

    Park, Jong Po

    2000-01-01

    Cause of excessive vibration with twice the rotational speed of a two-pole generator rotor for the fossil power plants was investigated. The two-pole generator rotor, treated as a typically asymmetric rotor in vibration analysis, produces asynchronous vibration with twice the rotational speed, sub-harmonic critical speeds, and potentially unstable operating zones due to its own inertia and/or stiffness asymmetry. This paper introduces a practical balancing procedure, and presents the results of the investigation on sources of the excessive vibration based on the experimental vibration data of the asymmetric two-pole rotor in balancing

  19. Wood pole overhead lines

    CERN Document Server

    Wareing, Brian

    2005-01-01

    This new book concentrates on the mechanical aspects of distribution wood pole lines, including live line working, environmental influences, climate change and international standards. Other topics include statutory requirements, safety, profiling, traditional and probabilistic design, weather loads, bare and covered conductors, different types of overhead systems, conductor choice, construction and maintenance. A section has also been devoted to the topic of lightning, which is one of the major sources of faults on overhead lines. The book focuses on the effects of this problem and the strate

  20. Endoscopic extradural supraorbital approach to the temporal pole and adjacent area: technical note.

    Science.gov (United States)

    Komatsu, Fuminari; Imai, Masaaki; Shigematsu, Hideaki; Aoki, Rie; Oda, Shinri; Shimoda, Masami; Matsumae, Mitsunori

    2017-08-25

    The authors' initial experience with the endoscopic extradural supraorbital approach to the temporal pole and adjacent area is reported. Fully endoscopic surgery using the extradural space via a supraorbital keyhole was performed for tumors in or around the temporal pole, including temporal pole cavernous angioma, sphenoid ridge meningioma, and cavernous sinus pituitary adenoma, mainly using 4-mm, 0° and 30° endoscopes and single-shaft instruments. After making a supraorbital keyhole, a 4-mm, 30° endoscope was advanced into the extradural space of the anterior cranial fossa during lifting of the dura mater. Following identification of the sphenoid ridge, orbital roof, and anterior clinoid process, the bone lateral to the orbital roof was drilled off until the dura mater of the anterior aspect of the temporal lobe was exposed. The dura mater of the temporal lobe was incised and opened, exposing the temporal pole under a 4-mm, 0° endoscope. Tumors in or around the temporal pole were safely removed under a superb view through the extradural corridor. The endoscopic extradural supraorbital approach was technically feasible and safe. The anterior trajectory to the temporal pole using the extradural space under endoscopy provided excellent visibility, allowing minimally invasive surgery. Further surgical experience and development of specialized instruments would promote this approach as an alternative surgical option.

  1. Regge-pole description of potential scattering by means of the phase-integral method

    International Nuclear Information System (INIS)

    Amaha, A.

    1992-01-01

    The application of Regge-pole theory to different atomic and molecular scattering has shown to have promising interpretational power in the differential cross sections. Differential cross sections can be analysed in terms of interference between the 'background' amplitude and a few Regge-pole positions of the scattering matrix (S matrix) representing surface waves around the interaction region. By the analytic continuation of the radial Schroedinger differential equation into the complex plane of angular momentum one can determine the analytic properties of the S matrix which contains the physical information in the scattering processes. For interaction potentials fulfilling certain properties, the study of the S matrix leads to the study of the F matrix introduced by Froeman and Froeman for the treatment of connection problems for phase-integral solutions of the differential equation. In this thesis the quantum mechanical scattering problem is analysed in the framework of Regge-pole theory with the use of the complex-angular-momentum formalism. To determine the S matrix, the relevant F matrix elements which give the stokes constants are derived and their properties are studied. The poles of the S matrix for particular complex values of the angular momentum quantum number are the Regge-poles. Using the Regge-pole positions and residues together with the background integral, the differential cross sections are calculated and compared with corresponding partial-wave representations

  2. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  3. CURRENT STATUS OF THE POLE-AND-LINE FISHERY IN EASTERN PART OF INDONESIA

    Directory of Open Access Journals (Sweden)

    Agustinus Anung Widodo

    2016-12-01

    Full Text Available The promotion of pole-and-line fishery for a selective gear operating in the Indonesian tuna management area is considered as the proper policy in response to the increasing market demand with tuna eco-labeled. Appropriate information in addressing the current status of the pole-and-line fishery in Indonesia is an important step in order to support the promotion. Data used to describe the fishery were obtained through scientific port sampling program in collaboration between RCFMC and WCPFC in 2010 to 2014 and also scientific observer onboard program collaboration RCFMC and CRAC Co. Ltd. in 2013. The results show that presently the number of pole and line fleets was decreased significantly and remain about 232 fleetsin Sorong, Bitung and Kendari and Larantuka. The national annual total catch of pole-and line during 1980 – 2013 was recorded between 24,000 and 160,000 tons per year (average 98,117 tons per year. This value is estimated to contribute about 20% of Indonesia annual total catch of tuna in FMAs713-717. The pole-andline catch rates based at Bitung, Kendari and Sorong were fluctuated in each year with the range respective between 8.79 and 17.93 tons/trip/vessel, 4.78 and 5.36 ton/trip/vessel and about 7,99 ton ton/trip/vessel. Pole-and-line fishery operated in Indonesian FMAs 713-717 is considered as selective fishery, with > 80 % catches of skipjack in matured stage. The tuna-live bait fish ratio in Indonesian pole-and-line was 4.41 :1, then an improvement of live bait ratio as well as its management is required.

  4. Texture of poled tetragonal PZT detected by synchrotron X-ray diffraction and micromechanics analysis

    International Nuclear Information System (INIS)

    Hall, D.A.; Steuwer, A.; Cherdhirunkorn, B.; Withers, P.J.; Mori, T.

    2005-01-01

    The texture and lattice elastic strain due to electrical poling of tetragonal PZT (lead zirconate titanate) ceramics have been measured using high energy synchrotron X-ray diffraction. It is shown that XRD peak intensity ratios associated with crystal planes of the form {002}, {112} and {202} exhibit a linear dependence on cos-bar 2 Ψ, where Ψ represents the orientation angle between the plane normal and the macroscopic poling axis. The observed dependence of texture and lattice strain on the grain orientation can be understood on the basis that the macroscopic strain due to poling is the average of the poling strains of all the individual grains

  5. STUDENT PLACEMENT

    African Journals Online (AJOL)

    User

    students express lack of interest in the field they are placed, it ... be highly motivated to learn than students placed in a department ... the following research questions. Research Questions. •. Did the criteria used by Mekelle. University for placement of students into different departments affect the academic performance of ...

  6. PolyPole-1: An accurate numerical algorithm for intra-granular fission gas release

    International Nuclear Information System (INIS)

    Pizzocri, D.; Rabiti, C.; Luzzi, L.; Barani, T.; Van Uffelen, P.; Pastore, G.

    2016-01-01

    The transport of fission gas from within the fuel grains to the grain boundaries (intra-granular fission gas release) is a fundamental controlling mechanism of fission gas release and gaseous swelling in nuclear fuel. Hence, accurate numerical solution of the corresponding mathematical problem needs to be included in fission gas behaviour models used in fuel performance codes. Under the assumption of equilibrium between trapping and resolution, the process can be described mathematically by a single diffusion equation for the gas atom concentration in a grain. In this paper, we propose a new numerical algorithm (PolyPole-1) to efficiently solve the fission gas diffusion equation in time-varying conditions. The PolyPole-1 algorithm is based on the analytic modal solution of the diffusion equation for constant conditions, combined with polynomial corrective terms that embody the information on the deviation from constant conditions. The new algorithm is verified by comparing the results to a finite difference solution over a large number of randomly generated operation histories. Furthermore, comparison to state-of-the-art algorithms used in fuel performance codes demonstrates that the accuracy of PolyPole-1 is superior to other algorithms, with similar computational effort. Finally, the concept of PolyPole-1 may be extended to the solution of the general problem of intra-granular fission gas diffusion during non-equilibrium trapping and resolution, which will be the subject of future work. - Highlights: • A new numerical algorithm (PolyPole-1) for intra-granular fission gas release in time-varying conditions is developed. • The concept combines the modal analytic solution for constant conditions and a polynomial correction. • PolyPole-1 is extensively verified and compared to other state-of-the-art algorithms. • PolyPole-1 exhibits a superior accuracy and a similar computational time relative to other algorithms. • The PolyPole-1 algorithm can be

  7. PolyPole-1: An accurate numerical algorithm for intra-granular fission gas release

    Energy Technology Data Exchange (ETDEWEB)

    Pizzocri, D. [Politecnico di Milano, Department of Energy, Nuclear Engineering Division, Via La Masa 34, 20156 Milano (Italy); Rabiti, C. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Luzzi, L.; Barani, T. [Politecnico di Milano, Department of Energy, Nuclear Engineering Division, Via La Masa 34, 20156 Milano (Italy); Van Uffelen, P. [European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, 76125 Karlsruhe (Germany); Pastore, G., E-mail: giovanni.pastore@inl.gov [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States)

    2016-09-15

    The transport of fission gas from within the fuel grains to the grain boundaries (intra-granular fission gas release) is a fundamental controlling mechanism of fission gas release and gaseous swelling in nuclear fuel. Hence, accurate numerical solution of the corresponding mathematical problem needs to be included in fission gas behaviour models used in fuel performance codes. Under the assumption of equilibrium between trapping and resolution, the process can be described mathematically by a single diffusion equation for the gas atom concentration in a grain. In this paper, we propose a new numerical algorithm (PolyPole-1) to efficiently solve the fission gas diffusion equation in time-varying conditions. The PolyPole-1 algorithm is based on the analytic modal solution of the diffusion equation for constant conditions, combined with polynomial corrective terms that embody the information on the deviation from constant conditions. The new algorithm is verified by comparing the results to a finite difference solution over a large number of randomly generated operation histories. Furthermore, comparison to state-of-the-art algorithms used in fuel performance codes demonstrates that the accuracy of PolyPole-1 is superior to other algorithms, with similar computational effort. Finally, the concept of PolyPole-1 may be extended to the solution of the general problem of intra-granular fission gas diffusion during non-equilibrium trapping and resolution, which will be the subject of future work. - Highlights: • A new numerical algorithm (PolyPole-1) for intra-granular fission gas release in time-varying conditions is developed. • The concept combines the modal analytic solution for constant conditions and a polynomial correction. • PolyPole-1 is extensively verified and compared to other state-of-the-art algorithms. • PolyPole-1 exhibits a superior accuracy and a similar computational time relative to other algorithms. • The PolyPole-1 algorithm can be

  8. Immediate placement and provisionalization of maxillary anterior single implant with guided bone regeneration, connective tissue graft, and coronally positioned flap procedures.

    Science.gov (United States)

    Waki, Tomonori; Kan, Joseph Y K

    2016-01-01

    Immediate implant placement and provisionalization in the esthetic zone have been documented with success. The benefit of immediate implant placement and provisionalization is the preservation of papillary mucosa. However, in cases with osseous defects presenting on the facial bony plate, immediate implant placement procedures have resulted in facial gingival recession. Subepithelial connective tissue grafts for immediate implant placement and provisionalization procedures have been reported with a good esthetic outcome. Biotype conversion around implants with subepithelial connective tissue grafts have been advocated, and the resulting tissues appear to be more resistant to recession. The dimensions of peri-implant mucosa in a thick biotype were significantly greater than in a thin biotype. Connective tissue graft with coronally positioned flap procedures on natural teeth has also been documented with success. This article describes a technique combining immediate implant placement, provisionalization, guided bone regeneration (GBR), connective tissue graft, and a coronally positioned flap in order to achieve more stable peri-implant tissue in facial osseous defect situations.

  9. The 'Pole Nucleaire Bourgogne' for developing the nuclear components industry

    International Nuclear Information System (INIS)

    Kottmann, G.

    2012-01-01

    The 'Pole Nucleaire Bourgogne' (PNB) is a high-technology and heavy industries cluster in Burgundy with an international calling. It aims at innovating, educating and federating in order to place the French nuclear industry in a leading position. PNB gathers 76 small-, and medium-sized enterprises, most of them operating in the metal sector, in design and in the control/measuring sector. The aim of PNB is to make enterprises work and cooperate on specific topics according to their sectors of activities and their skills. PNB has identified 3 domains of strategical innovations: -) ecological manufacturing and durability of heavy components, -) controls for high performance components, and -) maintenance and dismantling techniques in hostile environments. The various industry sectors represented in PNB allows a cross-fertilization between high-tech industries (aeronautics, energy, transportation)

  10. Radiography students' perceptions of clinical placements - A Nigerian perspective

    International Nuclear Information System (INIS)

    Ogbu, S.O.I.

    2008-01-01

    Purpose: To assess undergraduate radiography student perception of clinical placements and to evaluate their clinical learning experiences. Methods: To evaluate student perception of clinical placements, a Likert-scale questionnaire was used to assess clinical practice, the practice-learning environment. One hundred and seventy-eight undergraduate [student] radiographers participated in the study. Results: The students indicated they had adequate and enjoyed their time on the clinical placement. They also indicated the qualified staff was supportive, friendly and approachable. The students were able to achieve their learning outcomes during the placement. However placement venues, according to the students, had inadequate learning resources. No radiographic/medical imaging research findings, whether locally generated or otherwise, were used in clinical practice. Conclusions: Clinical placements had adequate student support. It provided a pleasant learning experience for the students and it enhanced their skills. Staff was willing and available to assist learning. Nevertheless, the training institutions, professional body and clinical placement providers need to make an effort to address inadequate learning resources (e.g. IT, library, study rooms) as well as the non-utilization of radiographic/medical imaging research findings

  11. Electrical power line and pole removal radiological survey completion report: Revision 2

    International Nuclear Information System (INIS)

    1989-02-01

    Each electric power pole and all wire, cross members, and attached hardware were radiologically surveyed and removed. The survey procedures did not conform in every respect with the planned procedures because the actual work differed from the removal plan. The survey showed that all contamination was fixed. Certain poles that were suspected of being contaminated with Th-230 were cut off one foot above ground level and left on site. Each truck load of materials was checked at the access point to ensure it met release criteria. Wood samples were taken from all the poles at Building 403 and 5% of all the rest and analyzed for U-238 and Th-232. Only U-238 was detected. 1903 bundles of wire (95,150 lin ft) were released, and 76 bundles (1520 lin ft) were found to be contaminated. 7163 lin ft of power pole material were released, and 1484 lin ft were contaminated. A comprehensive quality measure assurance/quality control program was applied to this work

  12. Instrument for analysis of electric motors based on slip-poles component

    Science.gov (United States)

    Haynes, Howard D.; Ayers, Curtis W.; Casada, Donald A.

    1996-01-01

    A new instrument for monitoring the condition and speed of an operating electric motor from a remote location. The slip-poles component is derived from a motor current signal. The magnitude of the slip-poles component provides the basis for a motor condition monitor, while the frequency of the slip-poles component provides the basis for a motor speed monitor. The result is a simple-to-understand motor health monitor in an easy-to-use package. Straightforward indications of motor speed, motor running current, motor condition (e.g., rotor bar condition) and synthesized motor sound (audible indication of motor condition) are provided. With the device, a relatively untrained worker can diagnose electric motors in the field without requiring the presence of a trained engineer or technician.

  13. POLE-LIKE STREET FURNITURE DECOMPOSTION IN MOBILE LASER SCANNING DATA

    OpenAIRE

    Li, F.; Oude Elberink, S.; Vosselman, G.

    2016-01-01

    Automatic semantic interpretation of street furniture has become a popular topic in recent years. Current studies detect street furniture as connected components of points above the street level. Street furniture classification based on properties of such components suffers from large intra class variability of shapes and cannot deal with mixed classes like traffic signs attached to light poles. In this paper, we focus on the decomposition of point clouds of pole-like street furniture. A nove...

  14. Entry-Level Placement Scores for the 1996-97 Academic Year.

    Science.gov (United States)

    Padron, Eduardo J.

    This memorandum reviews the implementation of new, state-mandated placement criteria at Florida's Miami-Dade Community College (MDCC). The first section focuses on placement criteria for degree-seeking students, indicating that MDCC uses scores on the Florida College Entry-Level Placement Test for making placement decisions in reading, writing,…

  15. Gamow-Jordan vectors and non-reducible density operators from higher-order S-matrix poles

    International Nuclear Information System (INIS)

    Bohm, A.; Loewe, M.; Maxson, S.; Patuleanu, P.; Puentmann, C.; Gadella, M.

    1997-01-01

    In analogy to Gamow vectors that are obtained from first-order resonance poles of the S-matrix, one can also define higher-order Gamow vectors which are derived from higher-order poles of the S-matrix. An S-matrix pole of r-th order at z R =E R -iΓ/2 leads to r generalized eigenvectors of order k=0,1,hor-ellipsis,r-1, which are also Jordan vectors of degree (k+1) with generalized eigenvalue (E R -iΓ/2). The Gamow-Jordan vectors are elements of a generalized complex eigenvector expansion, whose form suggests the definition of a state operator (density matrix) for the microphysical decaying state of this higher-order pole. This microphysical state is a mixture of non-reducible components. In spite of the fact that the k-th order Gamow-Jordan vectors has the polynomial time-dependence which one always associates with higher-order poles, the microphysical state obeys a purely exponential decay law. copyright 1997 American Institute of Physics

  16. Stressed out or subjective acquisition of competence – how do veterinary students see their curative work placement?

    Science.gov (United States)

    Dilly, Marc; Tipold, Andrea; Geuenich, Katja

    2016-01-01

    Veterinary studies in Germany are regulated by the Veterinary Certification Act (TAppV). The practical part of the education consists of 1,170 hours, whereby up to 850 hours can be spent on the curative work placement. A curative work placement can result in physical and psychological stress in the sense of a professional overload. It is the aim of this study to find out in what areas and to what extent competence is acquired and psychological stress exists in students during their work placement. Veterinary students (n=142) from all German education institutes participated in a voluntary online-study based on Burnout Screening Scales (BOSS) as well as a questionnaire regarding the acquisition of competence and excessive stress during the work placement (FKÜP). The distribution of values for work placement related stress show that such work placement related stress is generally slightly increased (T=60) and lies above that of occupational stresses within the normal population. Work placement related physical complaints also show a significant slight increase (T=61). A value (T=42) within the normal range was determined for the resource values. Few of the students questioned considered themselves to be excessively stressed in favour of a high subjective acquisition of competences. The largest increase regarding the acquisition of competence was noted for the areas of animal handling/restraint and application and injection techniques. In the sense of a perceived excessive demand regarding practical capabilities the areas of emergency management, surgery and medication dispensation were mentioned. With regard to the load structure and the acquisition of competence by veterinary students during their work placement, more support of the individual and a balancing of teaching/learning goals would be desirable and represents a promising approach. PMID:26958657

  17. Delayed bracket placement in orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Chandra Wigati

    2008-12-01

    Full Text Available Background: Beside bracket position, the timing of bracket placement is one of the most essential in orthodontic treatment with fixed appliances. Even it seems simple the timing of bracket placement can be crucial and significantly influence the result of orthodontic treatment. However it is often found brackets are placed without complete understanding of its purpose and effects, which could be useless and even detrimental for the case. Purpose: The aim of this case report is to show that the timing of bracket placement could be different depending on the cases. Case: Five different cases are presented here with different timing of bracket placement. Case management: On these cases, brackets were placed on the upper arch first, on the lower arch first, or even only on some teeth first. Good and efficient orthodontic treatment results were achieved. Conclusion: For every orthodontic case, from the very beginning of treatment, bracket should be placed with the end result in mind. If brackets are correctly placed at a correct time, better treatment result could be achieved without unnecessary round tripping tooth movement.

  18. Glass fiber -reinforced plastic tapered poles for transmission and distribution lines: development and experimental study

    International Nuclear Information System (INIS)

    Ibrahim, S.; Burachysnsky, V.; Polyzois, D.

    1999-01-01

    A research project to develop lightweight poles for use in power transmission and distribution lines and involving the use of glass fiber-reinforced plastic using the filament winding process is described. Twelve full scale specimen poles were designed, fabricated and subjected to cantilever bending to test failure modes. The test parameters included fiber orientation, ratio of longitudinal-to-circumferential fiber, and the number of layers. Results showed that local buckling was the most dominant failure mode, attributable to the high radius-to-thickness ratio of the specimen poles. Overall, however, these fiber-reinforced plastic poles compared favourably to wooden poles in carrying capacity with significant weight reduction. Lateral displacement at ultimate loads did not exceed the acceptable limit of 10 per cent of the specimen free length. 7 refs., 3 tabs., 2 figs

  19. A Sea-of-Gates Style FPGA Placement Algorithm

    Directory of Open Access Journals (Sweden)

    Kalapi Roy

    1996-01-01

    Full Text Available Field Programmable Gate Arrays (FPGAs have a pre-defined chip boundary with fixed cell locations and routing resources. Placement objectives for flexible architectures (e.g., the standard cell design style such as minimization of chip area do not reflect the primary placement goals for FPGAs. For FPGAs, the layout tools must seek 100% routability within the architectural constraints. Routability and congestion estimates must be made directly based on the demand and availability of routing resources for detailed routing of the particular FPGA. We. present a hierarchical placement approach consisting of two phases: a global placement phase followed by a detailed placement phase. The global placement phase minimizes congestion estimates of the global routing regions and satisfies all constraints at a coarser level. The detailed placer seeks to maximize the routability of the FPGA by considering factors which cause congestion at the detailed routing level and to precisely satisfy all of the constraints. Despite having limited knowledge about the gate level architectural details, we have achieved a 90%reduction in the number of unrouted nets in comparison to an industrial tool (the only other tool developed specifically for this architecture.

  20. Evidence for differentiation of cell wall poles in Bacillus subtilis

    International Nuclear Information System (INIS)

    Sonnenfeld, E.M.

    1985-01-01

    Previous data have suggested that the chromosome of Bacillus subtilis was found to the cell surface at polar regions. A significant corollary of DNA attachment to cell poles is the role of the cell wall in chromosome segregation. This project was mainly concerned with visualizing the DNA-cell wall association through autoradiography. The origin and terminus of replication were labelled with ( 3 H)-thymidine using a temperature-sensitive DNA initiation mutant. It was found that most of the radioactivity was associated with cell poles. Ultrastructural analyses of cell walls stained with dilute cationized ferritin showed that the polar area contained a site of dense electronegativity. It is not immediately apparent why cell wall poles would contain an area with a high concentration of negative charge. This finding may be related to the cell pole functioning as the site of chromosome attachment. An additional observation encountered in this study was that cell wall exhibited asymmetry with regard to negative charge, the outside surface being more electronegative than the inside. A significant consequence of this finding is that both teichoic acid and muramyl peptides are situated perpendicularly to the cell surface. This favored arrangement may facilitate cell separation during the division process due to opposition of like charges at septa. The results of this work provide further convincing evidence that the cell wall of B. subtilis is differentiated

  1. Poles Living in Ireland and their Quality of Life

    Directory of Open Access Journals (Sweden)

    Agnieszka NOLKA

    2009-05-01

    Full Text Available The economic growth of Ireland resulted in a significant number of Poles migrating to Ireland following the EU enlargement in 2004. The article explores the quality of life of Poles living in Ireland. Using data from a preliminary survey conducted in 2006, several dimensions of living conditions are analysed, including interpersonal relations, material security, health and healthcare. The study shows that evaluations of almost all aspects of quality of life improved, apart from components such as healthcare and the ability to acquire help from social organisations. Also interpersonal relations, contrary to the initial assumption, were enhanced by migration to Ireland.

  2. Confirmation of Essure placement using transvaginal ultrasound.

    Science.gov (United States)

    Veersema, Sebastiaan; Vleugels, Michel; Koks, Caroline; Thurkow, Andreas; van der Vaart, Huub; Brölmann, Hans

    2011-01-01

    To evaluate the protocol for confirmation of satisfactory Essure placement using transvaginal ultrasound. Prospective multicenter cohort study (Canadian Task Force classification II-2). Outpatient departments of 4 teaching hospitals in the Netherlands. Eleven hundred forty-five women who underwent hysteroscopic sterilization using the Essure device between March 2005 and December 2007. Transvaginal ultrasound examination 12 weeks after uncomplicated successful bilateral placement or as indicated according to the transvaginal ultrasound protocol after 4 weeks, and hysterosalpingography (HSG) at 12 weeks to confirm correct placement of the device after 3 months. The rate of successful placement was 88.4% initially. In 164 women (15%), successful placement was confirmed at HSG according the protocol. In 9 patients (0.84%), incorrect position of the device was observed at HSG. The cumulative pregnancy rate after 18 months was 3.85 per thousand women. Transvaginal ultrasound should be the first diagnostic test used to confirm the adequacy of hysteroscopic Essure sterilization because it is minimally invasive, averts ionizing radiation, and does not decrease the effectiveness of the Essure procedure. Copyright © 2011 AAGL. Published by Elsevier Inc. All rights reserved.

  3. The Dermal Apron Technique for Immediate Implant Socket Management: A Novel Technique.

    Science.gov (United States)

    Levin, Barry P

    2016-01-01

    With immediate implant placement and provisionalization (IIP) in the esthetic zone, measures to counter hard and soft tissue loss are frequently necessary. To reduce the morbidity associated with bone and connective tissue procurement, various exogenous materials are utilized. The "Dermal Apron Technique" presented in this article demonstrates the use of a composite bone particulate (allograft/xenograft) plus a dermal allograft, adapted around screw-retained temporary crowns and secured within a subperiosteal pouch. The purpose is to augment the thickness of peri-implant mucosa for the purpose of preserving ridge dimensions and preventing mucosal recession. Controlled studies are required to further support its use. Clinical significance: Soft tissue health and harmony are critical for successful implant therapy in the esthetic regions of the dentition. Often, autogenous soft tissue grafts are used to augment peri-implant soft tissues. The Dermal Apron Technique is a method, that in specific situations, obviates the need for autogenous grafting. This reduces treatment time and morbidity associated with procurement of these grafts. The Dermal Apron Technique is used simultaneous with immediate placement and provisionalization and can improve long-term esthetic outcomes for patients. © 2016 Wiley Periodicals, Inc.

  4. Robust high-precision attitude control for flexible spacecraft with improved mixed H2/H∞ control strategy under poles assignment constraint

    Science.gov (United States)

    Liu, Chuang; Ye, Dong; Shi, Keke; Sun, Zhaowei

    2017-07-01

    A novel improved mixed H2/H∞ control technique combined with poles assignment theory is presented to achieve attitude stabilization and vibration suppression simultaneously for flexible spacecraft in this paper. The flexible spacecraft dynamics system is described and transformed into corresponding state space form. Based on linear matrix inequalities (LMIs) scheme and poles assignment theory, the improved mixed H2/H∞ controller does not restrict the equivalence of the two Lyapunov variables involved in H2 and H∞ performance, which can reduce conservatives compared with traditional mixed H2/H∞ controller. Moreover, it can eliminate the coupling of Lyapunov matrix variables and system matrices by introducing slack variable that provides additional degree of freedom. Several simulations are performed to demonstrate the effectiveness and feasibility of the proposed method in this paper.

  5. Percutaneous pancreatic stent placement for postoperative pancreaticojejunostomy stenosis: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Koo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Yoon, Chang Jin [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-09-15

    Stenosis of the pancreatico-enteric anastomosis is one of the major complications of pancreaticoduodenectomy (PD). Endoscopic stent placement, has limited success rate as a nonsurgical treatment due to altered gastrointestinal anatomy. Percutaneous treatment is rarely attempted due to the technical difficulty in accessing the pancreatic duct. We reported a case of pancreaticojejunostomy stenosis after PD, in which a pancreatic stent was successfully placed using a rendezvous technique with a dual percutaneous approach.

  6. Percutaneous pancreatic stent placement for postoperative pancreaticojejunostomy stenosis: A case report

    International Nuclear Information System (INIS)

    Yang, Seung Koo; Yoon, Chang Jin

    2016-01-01

    Stenosis of the pancreatico-enteric anastomosis is one of the major complications of pancreaticoduodenectomy (PD). Endoscopic stent placement, has limited success rate as a nonsurgical treatment due to altered gastrointestinal anatomy. Percutaneous treatment is rarely attempted due to the technical difficulty in accessing the pancreatic duct. We reported a case of pancreaticojejunostomy stenosis after PD, in which a pancreatic stent was successfully placed using a rendezvous technique with a dual percutaneous approach

  7. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    Science.gov (United States)

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  8. Brand placement prominence: good for memory! Bad for attitudes?

    NARCIS (Netherlands)

    van Reijmersdal, E.

    2009-01-01

    This paper presents two laws about the effects of brand placement on audience reactions. This article presents two laws about the effects of brand placement on audience reactions. Brand placement is the compensated inclusion of brands or brand identifiers within media programming. The first law

  9. How media factors affect audience responses to brand placement

    NARCIS (Netherlands)

    van Reijmersdal, E.; Smit, E.; Neijens, P.

    2010-01-01

    This study investigates the influence of media factors on brand placement effects in a real-life setting. Although many studies on brand placement have been conducted, insights into context effects on brand placement reactions are scarce. The impact of objective and subjective media context factors

  10. The effect of poling conditions on the performance of piezoelectric energy harvesters fabricated by wet chemistry

    KAUST Repository

    Fuentes-Fernandez, Erika Maria-Anai

    2015-03-25

    The effect of poling conditions on the power output of piezoelectric energy harvesters using sol-gel based Pb(Zr0.53,Ti0.47)O3-Pb(Zn1/3,Nb2/3)O3 piezoelectric thin-films has been investigated. A strong correlation was established between the poling efficiency and harvester output. A method based on simple capacitance-voltage measurements is shown to be an effective approach to estimate the power output of harvesters poled under different conditions. The poling process was found to be thermally activated with an activation energy of 0.12 eV, and the optimum poling conditions were identified (200 kV cm-1, 250 °C for 50 min). The voltage output and power density obtained under optimum poling conditions were measured to be 558 V cm-2 and 325 μW cm-2, respectively. © The Royal Society of Chemistry.2015.

  11. Acute effects of walking with Nordic poles in persons with mild to moderate low-back pain.

    Science.gov (United States)

    Revord, Landon P; Lomond, Karen V; Loubert, Peter V; Hammer, Roger L

    2016-01-01

    Regular walking with or without Nordic poles is effective over time at reducing discomfort in individuals with chronic low back pain (LBP). Nordic pole use increases balance and stability, distributes weight through the arms and torso, and decreases loading of the spine and lower limbs. The purpose of this study was to determine if Nordic poles would reduce perceived acute discomfort while self-paced walking in individuals with LBP. We also examined whether walking with or without poles increased heart rate (HR) and ratings of perceived exertion (RPE) or speed of movement. Subjects included 20 adults (12 males, 8 females; mean age of 45.1±16.3) who were experiencing LBP of at least six months' duration (Oswestry Disability Index (ODI): mean 17 ± 8%, range 6-36% indicating minimal to moderate disability) with no current active flare-up. Participants walked a predetermined dirt-path course (805 m or 0.5 mi) with and without poles in randomized order. Data were analyzed using a 2 X 2 repeated measures ANOVA (Condition X Time), where Condition was poles vs no poles and Time was pre- and post-walk. HR and RPE increased significantly from walking the course, whereas pain did not change. There were also no differences between walking with or without poles for pain (ODI Sec #1: 0.2 points, p=0.324), HR (4 bpm, p=0.522) and RPE (0 points, p=0.759). The mean course time (sec) was slower with poles: 617±87 vs 566±65 (pNordic pole use is well tolerated in those with current back pain and can be encouraged, however it cannot be recommended as a superior method of addressing acute symptoms when walking.

  12. Impacted material placement plans

    International Nuclear Information System (INIS)

    Hickey, M.J.

    1997-01-01

    Impacted material placement plans (IMPP) are documents identifying the essential elements in placing remediation wastes into disposal facilities. Remediation wastes or impacted material(s) are those components used in the construction of the disposal facility exclusive of the liners and caps. The components might include soils, concrete, rubble, debris, and other regulatory approved materials. The IMPP provides the details necessary for interested parties to understand the management and construction practices at the disposal facility. The IMPP should identify the regulatory requirements from applicable DOE Orders, the ROD(s) (where a part of a CERCLA remedy), closure plans, or any other relevant agreements or regulations. Also, how the impacted material will be tracked should be described. Finally, detailed descriptions of what will be placed and how it will be placed should be included. The placement of impacted material into approved on-site disposal facilities (OSDF) is an integral part of gaining regulatory approval. To obtain this approval, a detailed plan (Impacted Material Placement Plan [IMPP]) was developed for the Fernald OSDF. The IMPP provides detailed information for the DOE, site generators, the stakeholders, regulatory community, and the construction subcontractor placing various types of impacted material within the disposal facility

  13. Semiclassical approach to Regge poles trajectories calculations for nonsingular potentials: Thomas-Fermi type

    International Nuclear Information System (INIS)

    Belov, S M; Avdonina, N B; Felfli, Z; Marletta, M; Msezane, A Z; Naboko, S N

    2004-01-01

    A simple semiclassical approach, based on the investigation of anti-Stokes line topology, is presented for calculating Regge poles for nonsingular (Thomas-Fermi type) potentials, namely potentials with singularities at the origin weaker than order -2. The anti-Stokes lines for Thomas-Fermi potentials have a more complicated structure than those of singular potentials and require careful application of complex analysis. The explicit solution of the Bohr-Sommerfeld quantization condition is used to obtain approximate Regge poles. We introduce and employ three hypotheses to obtain several terms of the Regge pole approximation

  14. A comparative study of onlay and retrorectus mesh placement in incisional hernia repair

    Directory of Open Access Journals (Sweden)

    Kundan Kharde

    2013-01-01

    Full Text Available Introduction: Incisional hernia after abdominal surgery is a well-known complication and the incidence of incisional hernias continues to be 2-11% after laparotomy. The repair of incisional hernia has always been a challenge to the surgeon. Various operative techniques for the repair of incisional hernia are in practice; however, the management is not standardized. The retro-rectus mesh placement or the sub-lay technique, popularized by Rives and Stoppa in Europe, has been reported to be quite effective, with low recurrence rates (0-23% and minimal complications. Aims and Objective: The purpose of this study was to compare the traditional on-lay mesh and retro-rectus mesh placement in incisional hernia repairs in terms of time taken for surgery, early complications (wound infections, Mesh extrusion, and Delayed complications (Recurrence. Materials and Methods: This is a prospective study which was conducted in the surgical department of our hospital. A total of 50 cases were included in this study. Of these cases, 25 cases were operated by the on-lay mesh method and 25 by retro-rectus mesh placement. Only the patients with midline hernias up to 10 cm in diameter were included in the study. Result: The operative time for retro-rectus mesh placement was insignificantly higher than that of on-lay mesh repair, whereas, complications like superficial Surgical site infection SSI were identical in both the study groups, but deep SSI leading to infection of mesh was higher in on-lay mesh repair. The recurrence rate was found to be 4% in on-lay mesh repair and 0% in retro-rectus mesh repair. Conclusion: The follow-up period in this study was 6months; hence, late recurrences were not taken into account. However, the low rate of local complications and the low recurrence rate indicate that retro-rectus mesh repair has an advantage over traditional on-lay repair.

  15. Do Work Placements Improve Final Year Academic Performance or Do High-Calibre Students Choose to Do Work Placements?

    Science.gov (United States)

    Jones, C. M.; Green, J. P.; Higson, H. E.

    2017-01-01

    This study investigates whether the completion of an optional sandwich work placement enhances student performance in final year examinations. Using Propensity Score Matching, our analysis departs from the literature by controlling for self-selection. Previous studies may have overestimated the impact of sandwich work placements on performance…

  16. Gender differences in power production, energetic capacity and efficiency of elite cross‑country skiers during whole‑body, upper‑body, and arm poling.

    Science.gov (United States)

    Hegge, Ann Magdalen; Bucher, Elias; Ettema, Gertjan; Faude, Oliver; Holmberg, Hans-Christer; Sandbakk, Øyvind

    2016-02-01

    To characterize gender differences in power output, energetic capacity and exercise efficiency during whole-body (WP), upper-body (UP), and arm poling (AP). Ten male and ten female elite cross-country skiers, matched for international performance level, completed three incremental submaximal tests and a 3-min self-paced performance test on a Concept2 SkiErg. Power output, cardiorespiratory and kinematic variables were monitored. Body composition was determined by dual-energy X-ray absorptiometry. The men demonstrated 87, 97 and 103% higher power output, and 51, 65 and 71% higher VO2peak (L min(−1)) than the women during WP, UP and AP, respectively, while utilizing ~10% more of their running VO2max in all modes (all P lean mass in the whole body, upper body and arms (all P production and peak aerobic capacity increased sequentially from WP to UP to AP, coinciding with a greater portion of the muscle mass in the arms of the men. Although the men and women employed each poling technique differently, the estimated efficiency of double poling was independent of gender.

  17. Usefulness and radiological evaluation of accuracy of innovative "Smart" hand technique for pedicle screw placement: an anatomical study.

    Science.gov (United States)

    Comert, Ayhan; Dogan, İhsan; Çaglar, Y Sukru

    2017-11-01

    The aim of this study is to use a smartphone application during pedicle screw placement navigation and examine the accuracy of this application on anatomical dry vertebrae model. 76 dry vertebrae were used for this study and pedicle entry points, projections of pedicle screw trajectory lines in lateral and superior aspect of vertebral body were identified and drawn for each vertebra bilaterally. In each position, all angulations were measured directly before the procedure manually. 152 pedicle screws were inserted as a simulation of screw placement with the guidance of angle-meter smart app. Accuracy of the method was tested according to the occurrence of bone penetration and angular deviation of the inserted screws was evaluated in computed tomography images. Mean deviation of pedicle screws of 76 pedicle screws in right side in horizontal plane was measured 2.30°±1.78°; in sagittal plane 2.17°±1.57° and in left side in horizontal plane 3.01°±1.83°; in sagittal plane 2.38°±1.68°. No bone penetration was occurred during 152 pedicle screw placements. According to the t-test results, there were significant differences between two groups in craniocaudal direction of the right side pedicle screws and in craniocaudal direction of left side pedicle screws. The free smartphone application presented here as angle-meter can be interpreted as a safe digital device for spinal instrumentation procedures. As a prototype of future pedicle screw fixation systems, it should be improved in terms of its feasibility and compatibility with screw probes. This may lead to apply mobile digital angle meter in spinal procedure.

  18. Fabrication of miniature magnetic magnet pole for validate simulation of magnetic cyclotron proton 13 MeV

    International Nuclear Information System (INIS)

    Subroto; Sukiya; Tony R

    2013-01-01

    A fabrication of miniature magnetic pole field has been made to validate the simulation system 13 MeV magnet of proton cyclotron using mild steel material. This electromagnet of magnetic pole at the end of the magnetic pole is divided into 8 parts of the valley and the hill interval to produce different magnetic field. Pole magnetic field fabrication is meet to match the design of the system simulation results 13 MeV cyclotron magnet. This requires strong cyclotron magnetic field average at 1.275 T magnetic field strength of each piece was different. So that the ion beam passing through a magnetic field. Will be focused before mashing target. The surface of magnetic pole is circular with a diameter of 100 mm and 32 mm pole spacing. Miniature of electrical pole diameter is only one-tenth the diameter of 960 mm designed this requires current 10 A with voltage 30 V to produce field strength of 0.3 T. To measure the magnetic field strength tesla meter is used and to measure the relationship curve in pole position with a magnetic field strength magnets cylinder directions X and Y the used mini lathe. Field strength measurement results with a straight, oblique and circular position show nearly equal to curve simulation results using a 3D module TOSCA opera program. (author)

  19. Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review.

    Science.gov (United States)

    Calcara, Calcedonio; Broglia, Laura; Comi, Giovanni; Balzarini, Marco

    2016-02-05

    Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.

  20. Neural network for optimal capacitor placement and its impact on power quality in electric distribution systems

    International Nuclear Information System (INIS)

    Mohamed, A.A.E.S.

    2013-01-01

    Capacitors are widely installed in distribution systems for reactive power compensation to achieve power and energy loss reduction, voltage regulation and system capacity release. The extent of these benefits depends greatly on how the capacitors are placed on the system. The problem of how to place capacitors on the system such that these benefits are achieved and maximized against the cost associated with the capacitor placement is termed the general capacitor placement problem. The capacitor placement problem has been formulated as the maximization of the savings resulted from reduction in both peak power and energy losses considering capacitor installation cost and maintaining the buses voltage within acceptable limits. After an appropriate analysis, the optimization problem was formulated in a quadratic form. For solving capacitor placement a new combinatorial heuristic and quadratic programming technique has been presented and applied in the MATLAB software. The proposed strategy was applied on two different radial distribution feeders. The results have been compared with previous works. The comparison showed the validity and the effectiveness of this strategy. Secondly, two artificial intelligence techniques for predicting the capacitor switching state in radial distribution feeders have been investigated; one is based on basis Radial Basis Neural Network (RBNN) and the other is based on Adaptive Neuro-Fuzzy Inference System (ANFIS). The ANFIS technique gives better results with a minimum total error compared to RBNN. The learning duration of ANFIS was very short than the neural network case. It implied that ANFIS reaches to the target faster than neural network. Thirdly, an artificial intelligence (RBNN) approach for estimation of transient overvoltage during capacitor switching has been studied. The artificial intelligence approach estimated the transient overvoltages with a minimum error in a short computational time. Finally, a capacitor switching

  1. A Principle and Winding Design of Consequent-Pole Bearingless Motors

    Science.gov (United States)

    Takenaga, Tomohiro; Kubota, Yutaka; Chiba, Akira; Fukao, Tadashi

    Recently, bearingless motors have been developed to enhance motor drive systems with magnetic suspension. Several types of motors have been proposed as bearingless motors, such as induction, surface mounted permanent magnet, inset permanent magnet, interior permanent magnet, buried permanent magnet, homopolar, hybrid, and switched reluctance bearingless motors. Permanent magnet bearingless motors have been attracting more interests in these years because of the high efficiency. In this paper, a consequent-pole bearingless motor is proposed. A rotor has buried permanent magnets, of which polarities are like. The radial force of a consequent-pole bearingless motor is generated by dc current. Thus, rotational angular position is not needed in a magnetic suspension controller. Radial force variations caused by a rotor rotation are minimized by improving arrangement of stator suspension conductors. A prototype bearingless motor and its controller are built. In experiment, principles of magnetic suspension in the proposed consequent-pole bearingless drive are confirmed.

  2. Two-Degree-of-Freedom Self-Tuning Control for Motor Drives Using Pole-Zero Cancellation Method

    Science.gov (United States)

    Takano, Akio

    In this paper, we present an excellent method named pole-zero cancellation (PZC) for designing motor control systems. PZC is performed in the z plane. A control system consists of three controllers, i.e., a speed controller, a position controller, and an adaptive identifier. The speed controller has two degrees of freedom: disturbance suppression and tracking speed, both of which can be regulated. The pulse transfer function used for regulating the tracking speed has two poles and one zero. When one pole and one zero coincide and cancel each other, the pulse transfer function is of the first-order lag type, and overshoots do not appear. The adaptive controller determines the coefficients of the pulse transfer function and adjusts the speed controller automatically so that the poles and zeros coincide. The transfer function of the position controller also has one pole and one zero, which cancel another pole and zero; pole 1 in the closed loop is not cancelled, and hence, position overshoots do not appear. A 2.2-kW induction motor is tested. The motor torque is controlled using a rapid torque control method. In this paper, first, the tracking-speed characteristics and the tracking-position characteristics are presented. Next, the identified transient coefficients are given, and finally, the disturbance-suppression characteristics are discussed. The experimental results prove the usefulness of the proposed method.

  3. Placement education pedagogy as social participation: what are students really learning?

    Science.gov (United States)

    Kell, Clare

    2014-03-01

    This paper draws on empirical fieldwork data of naturally occurring UK physiotherapy placement education to make visible how education is actually carried out and suggest what students may be learning through their placement interactions. The data challenge everyone involved in placement education design and practice to consider the values and practices students are learning to perpetuate through placement education experiences. The researcher undertook an ethnomethodologically informed ethnographic observation of naturally occurring physiotherapy placement education in two UK NHS placement sites. This study adopted a social perspective of learning to focus on the minutiae of placement educator, student and patient interaction practices during student-present therapeutic activities. Two days of placement for each of six senior students were densely recorded in real-time focussing specifically on the verbal, kinesics and proxemics-based elements of the participants' interaction practices. Repeated cycles of data analysis suggested consistent practices irrespective of the placement, educators, students or patients. The data suggest that placement education is a powerful situated learning environment in which students see, experience and learn to reproduce the physiotherapy practices valued by the local placement. Consistently, placement educators and students co-produced patient-facing activities as spectacles of physiotherapy-as-science. In each setting, patients were used as person-absent audiovisual teaching aids from which students learnt to make a case for physiotherapy intervention. The paper challenges physiotherapists and other professions using work-placement education to look behind the rhetoric of their placement documentation and explore the reality of students' learning in the field. The UK-based physiotherapy profession may wish to consider further the possible implications of its self-definition as a 'science-based healthcare profession' on its in

  4. Renormalization Group Invariance of the Pole Mass in the Multi-Higgs System

    Science.gov (United States)

    Kim, Chungku

    2018-06-01

    We have investigated the renormalization group running of the pole mass in the multi-Higgs theory in two different types of gauge fixing conditions. The pole mass, when expressed in terms of the Lagrangian parameters, turns out to be invariant under the renormalization group with the beta and gamma functions of the symmetric phase.

  5. Bedside intravascular ultrasound-guided inferior vena cava filter placement in medical-surgical intensive care critically-ill patients

    Directory of Open Access Journals (Sweden)

    Mohammad A. Abusedera

    2015-09-01

    Conclusions: Bedside IVUS-guided filter placement in medical-surgical critically ill patient in intensive care unit is a feasible, safe and reliable technique for IVC interruption. IVUS may be the most appropriate tool to guide filter insertion in obese patient.

  6. Internship guide : Work placements step by step

    NARCIS (Netherlands)

    Haag, Esther

    2013-01-01

    Internship Guide: Work Placements Step by Step has been written from the practical perspective of a placement coordinator. This book addresses the following questions : what problems do students encounter when they start thinking about the jobs their degree programme prepares them for? How do you

  7. Use of gadolinium chelate to confirm epidural needle placement in patients with an iodinated contrast reaction

    International Nuclear Information System (INIS)

    Shetty, Sanjay K.; Nelson, Erik N.; Lawrimore, Tara M.; Palmer, William E.

    2007-01-01

    administration. During the same time period, there were 11/2,067 (0.5%) instances of intrathecal needle placement discovered during attempted epidurography despite the use of fluoroscopy for needle guidance and reliance on loss-of-resistance technique. Gadolinium chelate represents a safe and useful alternative contrast agent for confirmation of epidural needle placement in patients with an iodinated contrast allergy. (orig.)

  8. Use of gadolinium chelate to confirm epidural needle placement in patients with an iodinated contrast reaction

    Energy Technology Data Exchange (ETDEWEB)

    Shetty, Sanjay K. [Massachusetts General Hospital, Harvard Medical School, Division of Musculoskeletal Radiology, Department of Radiology, Boston, MA (United States); Beth Israel Deaconess Medical Center, Harvard Medical School, Department of Radiology, Boston, MA (United States); Nelson, Erik N.; Lawrimore, Tara M.; Palmer, William E. [Massachusetts General Hospital, Harvard Medical School, Division of Musculoskeletal Radiology, Department of Radiology, Boston, MA (United States)

    2007-04-15

    administration. During the same time period, there were 11/2,067 (0.5%) instances of intrathecal needle placement discovered during attempted epidurography despite the use of fluoroscopy for needle guidance and reliance on loss-of-resistance technique. Gadolinium chelate represents a safe and useful alternative contrast agent for confirmation of epidural needle placement in patients with an iodinated contrast allergy. (orig.)

  9. An RTT-Aware Virtual Machine Placement Method

    Directory of Open Access Journals (Sweden)

    Li Quan

    2017-12-01

    Full Text Available Virtualization is a key technology for mobile cloud computing (MCC and the virtual machine (VM is a core component of virtualization. VM provides a relatively independent running environment for different applications. Therefore, the VM placement problem focuses on how to place VMs on optimal physical machines, which ensures efficient use of resources and the quality of service, etc. Most previous work focuses on energy consumption, network traffic between VMs and so on and rarely consider the delay for end users’ requests. In contrast, the latency between requests and VMs is considered in this paper for the scenario of optimal VM placement in MCC. In order to minimize average RTT for all requests, the round-trip time (RTT is first used as the metric for the latency of requests. Based on our proposed RTT metric, an RTT-Aware VM placement algorithm is then proposed to minimize the average RTT. Furthermore, the case in which one of the core switches does not work is considered. A VM rescheduling algorithm is proposed to keep the average RTT lower and reduce the fluctuation of the average RTT. Finally, in the simulation study, our algorithm shows its advantage over existing methods, including random placement, the traffic-aware VM placement algorithm and the remaining utilization-aware algorithm.

  10. Clinical placements in mental health: a literature review.

    Science.gov (United States)

    Happell, Brenda; Gaskin, Cadeyrn J; Byrne, Louise; Welch, Anthony; Gellion, Stephen

    2015-01-01

    Gaining experience in clinical mental health settings is central to the education of health practitioners. To facilitate the ongoing development of knowledge and practice in this area, we performed a review of the literature on clinical placements in mental health settings. Searches in Academic Search Complete, CINAHL, Medline and PsycINFO databases returned 244 records, of which 36 met the selection criteria for this review. Five additional papers were obtained through scanning the reference lists of those papers included from the initial search. The evidence suggests that clinical placements may have multiple benefits (e.g. improving students' skills, knowledge, attitudes towards people with mental health issues and confidence, as well as reducing their fears and anxieties about working in mental health). The location and structure of placements may affect outcomes, with mental health placements in non-mental health settings appearing to have minimal impact on key outcomes. The availability of clinical placements in mental health settings varies considerably among education providers, with some students completing their training without undertaking such structured clinical experiences. Students have generally reported that their placements in mental health settings have been positive and valuable experiences, but have raised concerns about the amount of support they received from education providers and healthcare staff. Several strategies have been shown to enhance clinical placement experiences (e.g. providing students with adequate preparation in the classroom, implementing learning contracts and providing clinical supervision). Educators and healthcare staff need to work together for the betterment of student learning and the healthcare professions.

  11. The Dimensions and Pole of Asteroid (21) Lutetia from Adaptive Optics Images

    Science.gov (United States)

    Drummond, Jack D.; Conrad, A.; Merline, W.; Carry, B.

    2009-09-01

    In a campaign to study the Rosetta mission target, asteroid (21) Lutetia, we obtained 81 images on December 2, 2008, at 2.12 microns with adaptive optics (AO) on the Keck-II 10 m telescope. From these nearly consecutive images obtained over a quarter of rotation, we have determined the asteroid's triaxial ellipsoid diameters to be 132x101x76 km, with formal uncertainties of 1 km for the equatorial dimensions, and 31 km for the shortest axis. This latter uncertainty occurs because the observations were made at the relatively high sub-Earth latitude of -69 degrees. From these observations we determine that Lutetia's pole lies at 2000.0 coordinates of RA=48, Dec=+9, or Ecliptic coordinates of [49;-8], with a formal uncertainty radius of 3 deg. (The other possible pole is eliminated by considering its lightcurve history.) The rotational pole derived for the lightcurve inversion model (available at http://astro.troja.mff.cuni.cz/ projects/asteroids3D/web.php), is only 5 deg from ours, but comparing our images to the lightcurve inversion model we find that Lutetia is more pointed than the model. Our technique of deriving the dimensions of asteroids from AO images has been calibrated against Pluto and 4 satellites of Saturn with precise diameters, and we find that any systematic errors can be no more than 1-3%. We acknowledge the assistance of other team members Christophe Dumas (ESO), Peter Tamblyn (SwRI), and Clark Chapman (SwRI). We also thank Hal Weaver (JHU/APL) as the lead for our collaboration with the Rosetta mission. We are grateful for telescope time made available to us by S. Kulkarni and M. Busch (Cal Tech) for a portion of our overall Lutetia effort. We also thank our collaborators on Team Keck, the Keck science staff, for making possible some of the Lutetia observations and for their participation. Additional Lutetia observations were acquired at Gemini North under NOAO time allocation.

  12. Unified Power Flow Controller Placement to Improve Damping of Power Oscillations

    OpenAIRE

    M. Salehi; A. A. Motie Birjandi; F. Namdari

    2015-01-01

    Weak damping of low frequency oscillations is a frequent phenomenon in electrical power systems. These frequencies can be damped by power system stabilizers. Unified power flow controller (UPFC), as one of the most important FACTS devices, can be applied to increase the damping of power system oscillations and the more effect of this controller on increasing the damping of oscillations depends on its proper placement in power systems. In this paper, a technique based on controllability is pro...

  13. Novel Treatment of a Scapholunate Ligament Injury with Proximal Pole Scaphoid Nonunion

    Science.gov (United States)

    Gaspar, Michael P.; Kane, Patrick M.; Jacoby, Sidney M.; Culp, Randall W.

    2016-01-01

    Background  Nonunion of scaphoid proximal pole fractures presents a challenging management dilemma to hand surgeons. This problem is further complicated in the uncommon concurrence of scapholunate (SL) ligament disruption. Case Description  A 39-year-old male patient presented with new-onset wrist pain following a remote history of a proximal pole scaphoid fracture sustained as a teenager, which was treated nonoperatively. Six months before presentation, the patient sustained a fall while snowboarding. The patient was found to have a chronic nonunion of his scaphoid proximal pole with an associated SL ligament disruption. As the proximal fragment was too small to be amenable to fixation, the patient was treated with an arthroscopic partial scaphoid excision and SL ligament reconstruction using a scapholunateintercarpal screw placed percutaneously. At 26 months, the patient exhibited no pain, near-normal strength, and wrist motion, and expressed a high-level of satisfaction from his surgery. Literature Review  Although cases of SL ligament disruption with concomitant proximal scaphoid fractures have been reported, to our knowledge, this is the first report of SL ligament rupture occurring in the setting of a preexisting proximal pole scaphoid nonunion. Clinical Relevance  We report the use of SL ligament reconstruction augmented with intercarpal screw fixation, and excision of the proximal pole scaphoid nonunion. This minimallyinvasive approach may be a particularly useful option in young, active patients such as our own, where a motion-sacrificing salvage procedure would be less than ideal. PMID:27616829

  14. A Simple Technique of Supine Craniospinal Irradiation

    International Nuclear Information System (INIS)

    Munshi, Anusheel; Jalali, Rakesh

    2008-01-01

    We describe a simple procedure of craniospinal irradiation in supine position. The procedure was carried out with a 100-cm isocenter linear accelerator and compatible simulator. Treatment was with a 1 or 2 posteroanterior (PA)-directed spinal fields abutting lateral-directed cranial fields. Abutment of the fields was established by placement of markers on the neck of the patient, which provided a measure of the divergence of the spinal field. The precision and reproducibility of this technique, including the placement of junctions, appeared to be as good as for treatment in the prone position. The same could be verified with port films. We conclude that this new technique of supine craniospinal treatment is a simple and convenient alternative to traditional treatment in the prone position

  15. On nonlinear differential equation with exact solutions having various pole orders

    International Nuclear Information System (INIS)

    Kudryashov, N.A.

    2015-01-01

    We consider a nonlinear ordinary differential equation having solutions with various movable pole order on the complex plane. We show that the pole order of exact solution is determined by values of parameters of the equation. Exact solutions in the form of the solitary waves for the second order nonlinear differential equation are found taking into account the method of the logistic function. Exact solutions of differential equations are discussed and analyzed

  16. Direct kinetochore?spindle pole connections are not required for chromosome segregation

    OpenAIRE

    Sikirzhytski, Vitali; Magidson, Valentin; Steinman, Jonathan B.; He, Jie; Le Berre, Ma?l; Tikhonenko, Irina; Ault, Jeffrey G.; McEwen, Bruce F.; Chen, James K.; Sui, Haixin; Piel, Matthieu; Kapoor, Tarun M.; Khodjakov, Alexey

    2014-01-01

    Segregation of genetic material occurs when chromosomes move to opposite spindle poles during mitosis. This movement depends on K-fibers, specialized microtubule (MT) bundles attached to the chromosomes? kinetochores. A long-standing assumption is that continuous K-fibers connect every kinetochore to a spindle pole and the force for chromosome movement is produced at the kinetochore and coupled with MT depolymerization. However, we found that chromosomes still maintained their position at the...

  17. Brand Placement and Consumer Choice: An in-Store Experiment

    Science.gov (United States)

    Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon

    2009-01-01

    An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior.…

  18. Magnetic transmission gear finite element simulation with iron pole hysteresis

    Science.gov (United States)

    Filippini, Mattia; Alotto, Piergiorgio; Glehn, Gregor; Hameyer, Kay

    2018-04-01

    Ferromagnetic poles in a magnetic transmission gear require particular attention during their design process. Usually, during the numerical simulation of these devices the effects of hysteresis for loss estimation are neglected and considered only during post-processing calculations. Since the literature lacks hysteresis models, this paper adopts a homogenized hysteretic model able to include eddy current and hysteresis losses in 2D laminated materials for iron poles. In this article the results related to the hysteresis in a magnetic gear are presented and compared to the non-hysteretic approach.

  19. Quasiparticle pole strength in nuclear matter

    International Nuclear Information System (INIS)

    Poggioli, R.S.; Jackson, A.D.

    1975-01-01

    It is argued that single-particle-like behavior in nuclear matter is much less probable than Brueckner theory suggests. In particular, the quasiparticle pole strength is evaluated for nuclear matter and it is shown that, contrary to the spirit of Brueckner theory, low momentum states play a crucial role in determining the magnitude of z/sub k/sub F/. (auth)

  20. Separate Poles Mode for Large-Capacity HVDC System

    Science.gov (United States)

    Zhu, Lin; Gao, Qin

    2017-05-01

    This paper proposes a novel connection mode, separate poles mode (SPM), for large-capacity HVDC systems. The proposed mode focuses on the core issues of HVDC connection in interconnected power grids and principally aims at increasing effective electric distance between poles, which helps to mitigate the interaction problems between AC system and DC system. Receiving end of bipolar HVDC has been divided into different inverter stations under the mode, and thus significantly alleviates difficulties in power transmission and consumption of receiving-end AC grids. By investigating the changes of multi-feed short-circuit ratio (MISCR), finding that HVDC with SPM shows critical impacts upon itself and other HVDC systems with conventional connection mode, which demonstrates that SPM can make balance between MISCR increase and short-circuit current limit.

  1. Geometric leaf placement strategies

    International Nuclear Information System (INIS)

    Fenwick, J D; Temple, S W P; Clements, R W; Lawrence, G P; Mayles, H M O; Mayles, W P M

    2004-01-01

    Geometric leaf placement strategies for multileaf collimators (MLCs) typically involve the expansion of the beam's-eye-view contour of a target by a uniform MLC margin, followed by movement of the leaves until some point on each leaf end touches the expanded contour. Film-based dose-distribution measurements have been made to determine appropriate MLC margins-characterized through an index d 90 -for multileaves set using one particular strategy to straight lines lying at various angles to the direction of leaf travel. Simple trigonometric relationships exist between different geometric leaf placement strategies and are used to generalize the results of the film work into d 90 values for several different strategies. Measured d 90 values vary both with angle and leaf placement strategy. A model has been derived that explains and describes quite well the observed variations of d 90 with angle. The d 90 angular variations of the strategies studied differ substantially, and geometric and dosimetric reasoning suggests that the best strategy is the one with the least angular variation. Using this criterion, the best straightforwardly implementable strategy studied is a 'touch circle' approach for which semicircles are imagined to be inscribed within leaf ends, the leaves being moved until the semicircles just touch the expanded target outline

  2. APHiD: Hierarchical Task Placement to Enable a Tapered Fat Tree Topology for Lower Power and Cost in HPC Networks

    Energy Technology Data Exchange (ETDEWEB)

    Michelogiannakis, George; Ibrahim, Khaled Z.; Shalf, John; Wilke, Jeremiah J.; Knight, Samuel; Kenny, Joseph P.

    2017-05-14

    The power and procurement cost of bandwidth in system-wide networks has forced a steady drop in the byte/flop ratio. This trend of computation becoming faster relative to the network is expected to hold. In this paper, we explore how cost-oriented task placement enables reducing the cost of system-wide networks by enabling high performance even on tapered topologies where more bandwidth is provisioned at lower levels. We describe APHiD, an efficient hierarchical placement algorithm that uses new techniques to improve the quality of heuristic solutions and reduces the demand on high-level, expensive bandwidth in hierarchical topologies. We apply APHiD to a tapered fat-tree, demonstrating that APHiD maintains application scalability even for severely tapered network configurations. Using simulation, we show that for tapered networks APHiD improves performance by more than 50% over random placement and even 15% in some cases over costlier, state-of-the-art placement algorithms.

  3. Clitoral Pain Following Retropubic Midurethral Sling Placement

    Directory of Open Access Journals (Sweden)

    Melanie Christofferson, DO

    2015-12-01

    Conclusion: Clitoral pain symptoms following placement of a retropubic midurethral sling should be evaluated and promptly addressed, given the potential negative impact on the patient's sexual function. Christofferson M, Barnard J, and Montoya TI. Clitoral pain following retropubic midurethral sling placement. Sex Med 2015;3:346–348.

  4. A physical theory on placement of fertilizers

    NARCIS (Netherlands)

    Wit, de C.T.

    1953-01-01

    A theory was developed enabling calculation of the effect of any placement method of fertilizer on yield if the effect of one method is known.

    This theory was based on the following established facts. The reactions between soil and fertilizer rate are the same for broadcasting and placement

  5. Preliminary Analyses of Transmedia Adaptations of Pictorial Narratives and Aesthetic Pole Interpretations: Reflections on Theory

    Directory of Open Access Journals (Sweden)

    Yu-Chai Lai

    2015-10-01

    Full Text Available Transmedia narratives are a key topic of communication research. Transmedia adaptations occur when a narrator transposes an original work by using various media platforms. Considering pictorial turn, this study employed the intermediality of an animated work that was adapted from an award-winning picture book as an example to propose an analysis for theory building. After examining the literature on transmedia narratives, intermediality, and aesthetic communication, this study proposed analyses for the dimensions of transmedia adaptations of pictorial narratives and aesthetic pole interpretations. Focusing on the three layers of the artistic pole, aesthetic pole, and interactions and effects, this study cited the cases of award-winning picture books and adapted animated works as the basis for reflecting on aesthetic communication. The artistic pole of transmedia adaptation was used as an example of how a narrator employs intermediality by citing the pictures, plot, or art forms from an original work to reinvent structures and then adapts them according to intermediality. If the aesthetic pole views the adapted animated work after reading the picture book or forms an expectation of the adaptation because of intermediality, then when the audience watches the adapted animated work, their imagination could be stimulated by the intermediality (i.e., picture book graphics and scene depictions. For transmedia narrative interaction, the aesthetic pole must “fill blanks” or “negate” to continue to view the adaptation. For filling blanks, because of intermediality, the aesthetic pole must construct an “intracompositional intermediality” to connect with the visual and audio links of the same work or construct “extracompositional intermedialtiy” to associate the original work with the transmedia adaptation. For negation, when viewing the adaptation (i.e., presentation of picture book graphics, added music, or theme song, the aesthetic pole

  6. Radiography students' perceptions of clinical placements - A Nigerian perspective

    Energy Technology Data Exchange (ETDEWEB)

    Ogbu, S.O.I. [Department of Medical Radiography and Radiological Sciences, University of Nigeria, Enugu Campus, 11 Clement Nnakwe Close, Ugbene, Abakpa-Nike, Enugu State 400001 (Nigeria)], E-mail: sylvogbu_rad@yahoo.com

    2008-05-15

    Purpose: To assess undergraduate radiography student perception of clinical placements and to evaluate their clinical learning experiences. Methods: To evaluate student perception of clinical placements, a Likert-scale questionnaire was used to assess clinical practice, the practice-learning environment. One hundred and seventy-eight undergraduate [student] radiographers participated in the study. Results: The students indicated they had adequate and enjoyed their time on the clinical placement. They also indicated the qualified staff was supportive, friendly and approachable. The students were able to achieve their learning outcomes during the placement. However placement venues, according to the students, had inadequate learning resources. No radiographic/medical imaging research findings, whether locally generated or otherwise, were used in clinical practice. Conclusions: Clinical placements had adequate student support. It provided a pleasant learning experience for the students and it enhanced their skills. Staff was willing and available to assist learning. Nevertheless, the training institutions, professional body and clinical placement providers need to make an effort to address inadequate learning resources (e.g. IT, library, study rooms) as well as the non-utilization of radiographic/medical imaging research findings.

  7. Factors influencing radiation therapy student clinical placement satisfaction

    Science.gov (United States)

    Bridge, Pete; Carmichael, Mary-Ann

    2014-01-01

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning. PMID:26229635

  8. Factors influencing radiation therapy student clinical placement satisfaction

    Energy Technology Data Exchange (ETDEWEB)

    Bridge, Pete; Carmichael, Mary-Ann [School of Clinical Sciences, Queensland University of Technology, Brisbane (Australia)

    2014-02-15

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning.

  9. Factors influencing radiation therapy student clinical placement satisfaction

    International Nuclear Information System (INIS)

    Bridge, Pete; Carmichael, Mary-Ann

    2014-01-01

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning

  10. Manufacturing aspects of the new Pole Face correcting coils for the PS main magnets

    CERN Document Server

    Bodart, D

    2011-01-01

    This document reports about the Pole Face Winding (PFW) installed in the Main Magnets of the PS accelerator. Composed by sets of 4 and installed on every magnet, they are made of copper conductors and installed directly on the poles of the magnets. Their role is to compensate the saturation effect of the pole shape of the magnet yoke and compensate the eddy current in the vacuum chambers. Their manufacturing has evolved over the years, the dedicated fabrication process and requirements are explained in this document.

  11. Crown Release Increases Diameter Growth and Bole Sprouting of Pole-Size Yellow Birch

    Science.gov (United States)

    Gayne G. Erdmann; Ralph M. Jr. Peterson

    1971-01-01

    During the second and third years after release, dominant, codominant, and intermediate pole-size yellow birch grew nearly twice as fast in diameter as unreleased poles. Growth rates were also related to foliage density. Epicormic sprouting was increased by crown release but most sprouting occured in the second log.

  12. Pacific Albacore Troll and Pole-and-line Fisheries

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The North Pacific and South Pacific Albacore Troll and Pole-and-line Fisheries project contains landings, logbooks, and size composition data from U.S.A. troll and...

  13. Minimally invasive piezosurgery for a safe placement of blade dental implants in jaws with severe bone loss

    Directory of Open Access Journals (Sweden)

    F. Rossi

    2014-10-01

    Full Text Available Aim :Severe atrophies of edentulous jaws require major reconstructive bone surgery in order to allow the placement of root-form implants with standard diameter. These bone augmentation techniques represent the best option reported in the literature, but they are often rejected by patients because of their high economic and biological costs in addition to the possibility of failure in the short and/or long term. In the maxilla regenerative methods (onlay, inlay, and distraction have high success rates, whereas in the mandible, especially in the distal atrophic area, they are not so predictable. In such situations an alternative technique for fixed prosthethic rebilitation is the insertion of platform blade implants, which have their elective indication for atrophic bone ridges with reduced width, owing to their reduced thickness. The aim of this study is to assess the effectiveness of the use of piezoelectric ultrasonic handpieces, in order to simplify the placement of blade implants, making it safer and less traumatic than with conventional surgical procedures. Materials and methods: Platform blade implants are extension implant functionally and aesthetically reliable, even if they require a more difficult surgical technique compared with the one currently in use for screw implants. A minimally invasive procedure by means of piezosurgery that was performed on 142 subjects is presented and a case is reported which highlights the successful results. Results: and conclusion The use of piezoelectric ultrasonic handpieces simplifies the surgical procedure for the placement of blade implant, making it safer and less traumatic.

  14. Prevalent lightning sferics at 600 megahertz near Jupiter's poles

    Science.gov (United States)

    Brown, Shannon; Janssen, Michael; Adumitroaie, Virgil; Atreya, Sushil; Bolton, Scott; Gulkis, Samuel; Ingersoll, Andrew; Levin, Steven; Li, Cheng; Li, Liming; Lunine, Jonathan; Misra, Sidharth; Orton, Glenn; Steffes, Paul; Tabataba-Vakili, Fachreddin; Kolmašová, Ivana; Imai, Masafumi; Santolík, Ondřej; Kurth, William; Hospodarsky, George; Gurnett, Donald; Connerney, John

    2018-06-01

    Lightning has been detected on Jupiter by all visiting spacecraft through night-side optical imaging and whistler (lightning-generated radio waves) signatures1-6. Jovian lightning is thought to be generated in the mixed-phase (liquid-ice) region of convective water clouds through a charge-separation process between condensed liquid water and water-ice particles, similar to that of terrestrial (cloud-to-cloud) lightning7-9. Unlike terrestrial lightning, which emits broadly over the radio spectrum up to gigahertz frequencies10,11, lightning on Jupiter has been detected only at kilohertz frequencies, despite a search for signals in the megahertz range12. Strong ionospheric attenuation or a lightning discharge much slower than that on Earth have been suggested as possible explanations for this discrepancy13,14. Here we report observations of Jovian lightning sferics (broadband electromagnetic impulses) at 600 megahertz from the Microwave Radiometer15 onboard the Juno spacecraft. These detections imply that Jovian lightning discharges are not distinct from terrestrial lightning, as previously thought. In the first eight orbits of Juno, we detected 377 lightning sferics from pole to pole. We found lightning to be prevalent in the polar regions, absent near the equator, and most frequent in the northern hemisphere, at latitudes higher than 40 degrees north. Because the distribution of lightning is a proxy for moist convective activity, which is thought to be an important source of outward energy transport from the interior of the planet16,17, increased convection towards the poles could indicate an outward internal heat flux that is preferentially weighted towards the poles9,16,18. The distribution of moist convection is important for understanding the composition, general circulation and energy transport on Jupiter.

  15. An Analysis Of Pole/zero Cancellation In LTR-based Feedback Design

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Jannerup, Ole Erik

    1990-01-01

    The pole/zero cancellation in LTR-based feedback design will be analyzed for both full-order as well as minimal-order observers. The asymptotic behaviour of the sensitivity function from the LTR-procedure are given in explicit expressions in the case when a zero is not cancelled by an equivalent...... pole. It will be shown that the non-minimum phase case is included as a special case. The results are not based on any specific LTR-method....

  16. Poling of PVDF matrix composites for integrated structural load sensing

    Science.gov (United States)

    Haghiashtiani, Ghazaleh; Greminger, Michael A.; Zhao, Ping

    2014-03-01

    The purpose of this study is to create and evaluate a smart composite structure that can be used for integrated load sensing and structural health monitoring. In this structure, PVDF films are used as the matrix material instead of epoxy resin or other thermoplastics. The reinforcements are two layers of carbon fiber with one layer of Kevlar separating them. Due to the electrical conductivity properties of carbon fiber and the dielectric effect of Kevlar, the structure acts as a capacitor. Furthermore, the piezoelectric properties of the PVDF matrix can be used to monitor the response of the structure under applied loads. In order to exploit the piezoelectric properties of PVDF, the PVDF material must be polarized to align the dipole moments of its crystalline structure. The optimal condition for poling the structure was found by performing a 23 factorial design of experiment (DoE). The factors that were studied in DoE were temperature, voltage, and duration of poling. Finally, the response of the poled structure was monitored by exposing the samples to an applied load.

  17. Posterior Pole Sparing Laser Photocoagulation Combined with Intravitreal Bevacizumab Injection in Posterior Retinopathy of Prematurity

    Directory of Open Access Journals (Sweden)

    Rebecca Kim

    2014-01-01

    Full Text Available Purpose. To report the results of the posterior pole sparing laser photocoagulation combined with intravitreal bevacizumab injection (IVB in retinopathy of prematurity (ROP. Methods. A retrospective chart review of premature babies with ROP, all of whom received laser photocoagulation with IVB. Eleven eyes of 6 infants with advanced zone I ROP underwent laser ablation sparing posterior pole with concurrent IVB. The results were compared with those of full-laser treatment combined with IVB to 8 eyes of 5 infants with advanced ROP without involvement of the posterior pole. Results. The posterior pole sparing laser with IVB was performed with zone I, stage 3+ ROP at the mean postmenstrual age of 36 weeks and 5 days. The plus sign decreased significantly at postoperative day 1, the neovascular proliferation regressed by postoperative week 1, and the normal vascularization started at postoperative day 32 on the average. Two months after treatment, vascularization of the spared avascular area was completed. There was no macular dragging, tractional retinal detachment, foveal destruction by laser scars, or any other adverse event. No significant anatomical differences were identified from those of full-laser ablation combined with IVB. Conclusions. Posterior pole sparing laser with IVB can give favorable results without destruction of posterior pole retina.

  18. Pragmatic Approach for Multistage Phasor Measurement Unit Placement

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Chen, Zhe; Thoegersen, Poul

    2016-01-01

    Effective phasor measurement unit (PMU) placement is a key to the implementation of efficient and economically feasible wide area measurement systems in modern power systems. This paper proposes a pragmatic approach for cost-effective stage-wise deployment of PMUs while considering realistic...... constraints. Inspired from a real world experience, the proposed approach optimally allocates PMU placement in a stage-wise manner. The proposed approach also considers large-scale wind integration for effective grid state monitoring of wind generation dynamics. The proposed approach is implemented...... on the Danish power system projected for the year 2040. Furthermore, practical experience learnt from an optimal PMU placement project aimed at PMU placement in the Danish power system is presented, which is expected to provide insight of practical challenges at ground level that could be considered by PMU...

  19. Transaxillary Subpectoral Placement of Cardiac Implantable Electronic Devices in Young Female Patients

    Directory of Open Access Journals (Sweden)

    Joo Hyun Oh

    2017-01-01

    Full Text Available BackgroundThe current indications of cardiac implantable electronic devices (CIEDs have expanded to include young patients with serious cardiac risk factors, but CIED placement has the disadvantage of involving unsightly scarring and bulging of the chest wall. A collaborative team of cardiologists and plastic surgeons developed a technique for the subpectoral placement of CIEDs in young female patients via a transaxillary approach.MethodsFrom July 2012 to December 2015, subpectoral CIED placement via an axillary incision was performed in 10 young female patients, with a mean age of 25.9 years and mean body mass index of 20.1 kg/m2. In the supine position, with the patient's shoulder abducted, an approximately 5-cm linear incision was made along one of the deepest axillary creases. The submuscular plane was identified at the lateral border of the pectoralis major, and the dissection continued over the clavipectoral fascia until the subpectoral pocket could securely receive a pulse generator. Slight upward dissection also exposed an entrance to the subclavian vein, allowing the cardiology team to gain access to the vein. One patient with dilated cardiomyopathy underwent augmentation mammoplasty and CIED insertion simultaneously.ResultsOne case of late-onset device infection occurred. All patients were highly satisfied with the results and reported that they would recommend the procedure to others.ConclusionsWith superior aesthetic outcomes compared to conventional methods, the subpectoral placement of CIEDs via a transaxillary approach is an effective, single-incision method to hide operative scarring and minimize bulging of the device, and is particularly beneficial for young female or lean patients.

  20. Claw-pole Synchronous Generator for Compressed Air Energy Storage

    Directory of Open Access Journals (Sweden)

    PAVEL Valentina

    2013-05-01

    Full Text Available This paper presents a claw-poles generator for compressed air energy storage systems. It is presented the structure of such a system used for compensating of the intermittency of a small wind energy system. For equipping of this system it is chosen the permanent magnet claw pole synchronous generator obtained by using ring NdFeB permanentmagnets instead of excitation coil. In such a way the complexity of the scheme is reduced and the generator become maintenance free. The new magnetic flux density in the air-gap is calculated by magneticreluctance method and by FEM method and the results are compared with measured values in the old and new generator.

  1. Private Placement Debt Financing for Public Entities

    Science.gov (United States)

    Holman, Lance S.

    2010-01-01

    Private placement financing is a debt or capital lease obligation arranged between a municipality or a 501(c) (3) not-for-profit organization and a single sophisticated institutional investor. The investor can be a bank, insurance company, finance company, hedge fund, or high-net worth individual. Private placement financing is similar to…

  2. Patterns of out-of-home placement decision-making in child welfare.

    Science.gov (United States)

    Chor, Ka Ho Brian; McClelland, Gary M; Weiner, Dana A; Jordan, Neil; Lyons, John S

    2013-10-01

    Out-of-home placement decision-making in child welfare is founded on the best interest of the child in the least restrictive setting. After a child is removed from home, however, little is known about the mechanism of placement decision-making. This study aims to systematically examine the patterns of out-of-home placement decisions made in a state's child welfare system by comparing two models of placement decision-making: a multidisciplinary team decision-making model and a clinically based decision support algorithm. Based on records of 7816 placement decisions representing 6096 children over a 4-year period, hierarchical log-linear modeling characterized concordance or agreement, and discordance or disagreement when comparing the two models and accounting for age-appropriate placement options. Children aged below 16 had an overall concordance rate of 55.7%, most apparent in the least restrictive (20.4%) and the most restrictive placement (18.4%). Older youth showed greater discordant distributions (62.9%). Log-linear analysis confirmed the overall robustness of concordance (odd ratios [ORs] range: 2.9-442.0), though discordance was most evident from small deviations from the decision support algorithm, such as one-level under-placement in group home (OR=5.3) and one-level over-placement in residential treatment center (OR=4.8). Concordance should be further explored using child-level clinical and placement stability outcomes. Discordance might be explained by dynamic factors such as availability of placements, caregiver preferences, or policy changes and could be justified by positive child-level outcomes. Empirical placement decision-making is critical to a child's journey in child welfare and should be continuously improved to effect positive child welfare outcomes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Pole masses of quarks in dimensional reduction

    International Nuclear Information System (INIS)

    Avdeev, L.V.; Kalmykov, M.Yu.

    1997-01-01

    Pole masses of quarks in quantum chromodynamics are calculated to the two-loop order in the framework of the regularization by dimensional reduction. For the diagram with a light quark loop, the non-Euclidean asymptotic expansion is constructed with the external momentum on the mass shell of a heavy quark

  4. CABLE MECHANISMS USED FOR ACTUATING CAR ELEVATORS WITH 2 AND 4 POLES

    Directory of Open Access Journals (Sweden)

    Dan MESARICI

    2015-05-01

    Full Text Available This paper presents the kinematic scheme and the operating mode of the cable mechanism used for car elevators with 2 and 4 poles. In order to increase the efficiency of the 4- pole elevator, we suggest using a new hoists type cable mechanism, which can multiply the piston travel inside the actuating cylinder twice at the platform level, when lifting and lowering.

  5. Disclosing brand placement to young children

    OpenAIRE

    De Pauw, Pieter; Hudders, Liselot; Cauberghe, Veroline; De Kuysscher, Charlotte

    2015-01-01

    Purpose – This article examines whether a television brand placement warning cue can alter young children’s susceptibility for advertising effects (i.e., brand attitude) through activating their advertising literacy. The proposed model also puts forward an important moderating role for children’s skeptical attitude toward the brand placement format. Design/methodology/approach – The data were collected among 63 children between 7 and 9 years old (Mage = 8.49; 51% girls) through a single...

  6. Laminated wood as an alternative to wood poles : Engineered wood structures for electric utility and telecommunications industries

    Energy Technology Data Exchange (ETDEWEB)

    Reisdorff, R. [Laminated Wood Systems Inc., Seward, NE (United States)

    2002-07-01

    In this PowerPoint presentation, the author discusses the major advantages of laminated structures, for both the electric and telecommunication industries. The advantages include economy, quick delivery, climbing and field modifications, dimensional uniformity and stability. A series of pictures was displayed which showed the manufacturing process. Laminated structures have a proven history. They were developed in Europe in 1890, and introduced to the United States in 1934. Framing members were introduced in the late 1940s, while poles were introduced in 1963, two years ahead of steel poles. Some of the electrical utility applications include: (1) distribution structures, (2) transmission structures such as single-pole, phase over phase switch structures, tangent structures, and H-Frame construction. The applications for the telecommunication industry consist of joint use structures, such as electric and telecommunication, lighting and telecommunication, overhead telephone and wireless; mono-pole applications; three-pole Bell Towers; and tree poles. Examples of each type were shown. figs.

  7. De novo radiologic placement of button gastrostomy: a feasibility study in children with cancer

    International Nuclear Information System (INIS)

    Richioud, Bertrand; Beji, Hedi; Kalenderian, Anne-Charlotte; Cuinet, Marie; Pilleul, Frank; Louazon, Typhaine; Bertrand, Amandine; Roux, Pascale; Marec-Berard, Perrine

    2015-01-01

    Primary placement of percutaneous radiologic button gastrostomy has been successfully performed in adults but research is lacking as to its success in children during cancer treatment. To assess the safety and effectiveness of such treatment at a single center. We conducted a 3-year retrospective feasibility study reporting on placement procedure, feeding plan, acute complications and effectiveness of this technique based on the evolution of the weight and weight-to-height during a period of 3 months. Eleven gastrostomies were performed in 11 children and young adults (3-20 years old) during oncological treatment. No major complications occurred. Two patients experienced minor side effects - local leakage and granulation tissue formation - both easily treated. In all cases, enteral feeding started within 24 h following the button placement. The patients were able to go home within 72 h. After 1 month, 64% (7/11) had gained weight, 18% (2/11) had maintained weight and 9% (1/11) had lost weight. After 3 months, 73% (8/11) had gained weight and 9% (1/11) had lost weight. The procedure and devices were well tolerated and mostly effective in our cohort. (orig.)

  8. De novo radiologic placement of button gastrostomy: a feasibility study in children with cancer

    Energy Technology Data Exchange (ETDEWEB)

    Richioud, Bertrand; Beji, Hedi; Kalenderian, Anne-Charlotte; Cuinet, Marie; Pilleul, Frank [Centre Leon Berard, Department of Radiology, Lyon (France); Louazon, Typhaine; Bertrand, Amandine; Roux, Pascale; Marec-Berard, Perrine [Institut d' Hematologie et d' Oncologie Pediatrique, Pediatric Oncology, Lyon (France)

    2015-12-15

    Primary placement of percutaneous radiologic button gastrostomy has been successfully performed in adults but research is lacking as to its success in children during cancer treatment. To assess the safety and effectiveness of such treatment at a single center. We conducted a 3-year retrospective feasibility study reporting on placement procedure, feeding plan, acute complications and effectiveness of this technique based on the evolution of the weight and weight-to-height during a period of 3 months. Eleven gastrostomies were performed in 11 children and young adults (3-20 years old) during oncological treatment. No major complications occurred. Two patients experienced minor side effects - local leakage and granulation tissue formation - both easily treated. In all cases, enteral feeding started within 24 h following the button placement. The patients were able to go home within 72 h. After 1 month, 64% (7/11) had gained weight, 18% (2/11) had maintained weight and 9% (1/11) had lost weight. After 3 months, 73% (8/11) had gained weight and 9% (1/11) had lost weight. The procedure and devices were well tolerated and mostly effective in our cohort. (orig.)

  9. 33 CFR 183.566 - Fuel pumps: Placement.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel pumps: Placement. 183.566...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.566 Fuel pumps: Placement. Each fuel pump must be on the engine it serves or within 12 inches of the engine, unless it is a...

  10. Adaptive pole placement: the division by zero problem

    NARCIS (Netherlands)

    Arent, Krzysztof; Arent, K.; Polderman, Jan W.; Mareels, I.M.Y.; Mareels, Iven

    1995-01-01

    We re-examine the division by zero problem which occurs in certainty equivalence based indirect adaptive control algorithms applied to linear systems. By exploiting a parametrization for linear systems induced by the continued fraction description of its transfer function, the division by zero

  11. A Study of Effect of Walking Pole on the Walking Exercise

    OpenAIRE

    加藤, 麻樹; 下平, 佳江; 佐藤, 健

    2010-01-01

    So-called metabolic syndrome is one of the medical problems in our country, because many of people have difficulty at lack of exercises. Ministry of Health, Labor and Welfare suggest healthy life by exercise and moderate foods. Walking is one of the effective exercises to keep health in everyday life. Walking with poles, the exercise method of cross country skiing, is noticed as the effective exercise nowadays. Some studies show the effect of the pole walking exercise from view points of c...

  12. The Re-Placement Test: Using TOEFL for Purposes of Placement

    Science.gov (United States)

    Moglen, Daniel

    2015-01-01

    This article will consider using TOEFL scores for purposes of placement and advising for international graduate students at a northern California research university. As the number of international students is on the rise and the funds for the graduate ESL program are diminishing, the way in which the university is handling the influx of…

  13. Completion evaluation of the Eagle Ford formation with heterogeneous proppant placement

    Energy Technology Data Exchange (ETDEWEB)

    Viswanathan, A.; Altman, R.; Oussoltsev, D.; Kanneganti, K.; Xu, J.; Grant, D.; Indriati, S.; Pena, A.; Loayza, M.; Kirkham, B.; Rhein, T. [Society of Petroleum Engineers (Canada)

    2011-07-01

    With the major developments of the Eagle Ford shale in Texas, there has been an increasing focus on the optimization of stimulation techniques. Many techniques have already been implemented in order to improve productivity across Eagle Ford. This paper analyzes completion techniques currently in place through the Hawkville field with the goal of determining key parameters and their impact on the well. The paper focuses mainly on channel fracturing based on a heterogeneous proppant placement technique and evaluates it against current slickwater and hybrid stimulation treatments. The evaluation described in the paper was conducted by first collecting data from 51 horizontal wells in the Eagle Ford formation. It then follows through the evaluation completing a normalized production comparison, a productivity index analysis, neural network trained self-organizing maps, and numerical simulations. Through evaluations and comparisons the paper shows that channel fracturing can allow for a significant improvement in production of dry gas wells.

  14. Tent-Poles of the Bestseller

    DEFF Research Database (Denmark)

    Jensen, Thessa; Vistisen, Peter

    2013-01-01

    This article proposes a framework for understanding and analysing how the passive audience of a media event turns into active stakeholders. The starting point is the cross-media content quadrant (Jensen and Vistisen, 2012), which shows how the producer’s control is distributed on social media...... platforms, while storytelling evolves around a tent-pole, for example, a bestseller or blockbuster. To further explain how the audience engages, a three-step rhetoric model largely based on Bitzer (1998) and Tolkien (1971) is developed and explained....

  15. New electronic filtering technique in digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Pozzi-Mucelli, R; Predonzan, F; Magnaldi, S; Godina, G

    1986-01-01

    The authors report their experience with a new electronic filtering technique in digital subtraction angiography (DSA). The principles of the technique are reported and the advantages in comparison with conventional filters are stressed (accurate and fast placement without fluoroscopic exposure). The system provided excellent results in about 900 DSA examinations.

  16. Application of HGSO to security based optimal placement and parameter setting of UPFC

    International Nuclear Information System (INIS)

    Tarafdar Hagh, Mehrdad; Alipour, Manijeh; Teimourzadeh, Saeed

    2014-01-01

    Highlights: • A new method for solving the security based UPFC placement and parameter setting problem is proposed. • The proposed method is a global method for all mixed-integer problems. • The proposed method has the ability of the parallel search in binary and continues space. • By using the proposed method, most of the problems due to line contingencies are solved. • Comparison studies are done to compare the performance of the proposed method. - Abstract: This paper presents a novel method to solve security based optimal placement and parameter setting of unified power flow controller (UPFC) problem based on hybrid group search optimization (HGSO) technique. Firstly, HGSO is introduced in order to solve mix-integer type problems. Afterwards, the proposed method is applied to the security based optimal placement and parameter setting of UPFC problem. The focus of the paper is to enhance the power system security through eliminating or minimizing the over loaded lines and the bus voltage limit violations under single line contingencies. Simulation studies are carried out on the IEEE 6-bus, IEEE 14-bus and IEEE 30-bus systems in order to verify the accuracy and robustness of the proposed method. The results indicate that by using the proposed method, the power system remains secure under single line contingencies

  17. The cos2φ azimuthal asymmetry of unpolarized dilepton production at the Z pole

    International Nuclear Information System (INIS)

    Lu Zhun; Schmidt, Ivan

    2011-01-01

    We calculate the Boer-Mulders effect contribution to the cos2φ azimuthal asymmetry of unpolarized dilepton production near the Z-pole. Based on the tree-level expression in the transverse momentum dependent factorization framework, we show that the corresponding asymmetry near the Z-pole is negative, which is opposite to the asymmetry in the low Q 2 region, dominated by the production via a virtual photon. We calculate the asymmetry generated by the Boer-Mulders effect near the Z-pole at the Relativistic Heavy Ion Collider (RHIC), with √(s)=500 GeV. We find that the magnitude of the asymmetry is several percent, and therefore it is measurable. The experimental confirmation of this sign change of the asymmetry from the low Q 2 region to the Z-pole provides direct evidence of the chiral-odd structure of quarks inside an unpolarized nucleon.

  18. S3 Dorsal Root Ganglion/Nerve Root Stimulation for Refractory Postsurgical Perineal Pain: Technical Aspects of Anchorless Sacral Transforaminal Lead Placement

    Directory of Open Access Journals (Sweden)

    X. Zuidema

    2016-01-01

    Full Text Available Chronic perineal pain limits patients in physical and sexual activities, leading to social and psychological distress. In most cases, this pain develops after surgery in the urogenital area or as a consequence of trauma. Neuromodulation is one of the options in chronic postsurgical perineal pain treatment. We present a case of refractory perineal pain after right sided surgical resection of a Bartholin’s cyst which was treated with third sacral nerve root/dorsal root ganglion stimulation using the transforaminal approach. We describe a new anchorless lead placement technique using a unique curved lead delivery sheath. We postulate that this new posterior foraminal technique of lead placement is simple, safe, and reversible and may lower the occurrence of lead related complications.

  19. Nordic walking versus walking without poles for rehabilitation with cardiovascular disease: Randomized controlled trial.

    Science.gov (United States)

    Girold, Sébastien; Rousseau, Jérome; Le Gal, Magalie; Coudeyre, Emmanuel; Le Henaff, Jacqueline

    2017-07-01

    With Nordic walking, or walking with poles, one can travel a greater distance and at a higher rate than with walking without poles, but whether the activity is beneficial for patients with cardiovascular disease is unknown. This randomized controlled trial was undertaken to determine whether Nordic walking was more effective than walking without poles on walk distance to support rehabilitation training for patients with acute coronary syndrome (ACS) and peripheral arterial occlusive disease (PAOD). Patients were recruited in a private specialized rehabilitation centre for cardiovascular diseases. The entire protocol, including patient recruitment, took place over 2 months, from September to October 2013. We divided patients into 2 groups: Nordic Walking Group (NWG, n=21) and Walking Group without poles (WG, n=21). All patients followed the same program over 4 weeks, except for the walk performed with or without poles. The main outcome was walk distance on the 6-min walk test. Secondary outcomes were maximum heart rate during exercise and walk distance and power output on a treadmill stress test. We included 42 patients (35 men; mean age 57.2±11 years and BMI 26.5±4.5kg/m 2 ). At the end of the training period, both groups showed improved walk distance on the 6-min walk test and treatment stress test as well as power on the treadmill stress test (PNordic walking training appeared more efficient than training without poles for increasing walk distance on the 6-min walk test for patients with ACS and PAOD. Copyright © 2017. Published by Elsevier Masson SAS.

  20. Fabrication of a Scaled MgB2 Racetrack Demonstrator Pole for a 10-MW Direct-Drive Wind Turbine Generator

    DEFF Research Database (Denmark)

    Magnusson, Niklas; Eliassen, Jan Christian; Abrahamsen, Asger Bech

    2018-01-01

    Field windings made of MgB2 wires or tapes are considered for their potential to reduce volume, weight, and cost of large offshore wind turbine generators. To gain experience of how to use this relatively new material in full-scale generators, tests of different winding methodologies and techniques...... are needed. In this paper, we describe in detail the steps used to wind a racetrack coil with a length of 1 m and a width of 0.5 m out of 4.5 km of MgB2 superconducting tape. The width corresponds to a full-scale pole of a 10-MW generator, whereas the length of the straight section is shorter than...... the corresponding full-scale pole. The coil was built up of ten double pancake coils. Each double pancake coil was wet wound using a semiautomatic winding process, where Stycast 2850 was applied directly to the MgB2 tape without any other dedicated electrical insulation. The strengths and weaknesses of the winding...