WorldWideScience

Sample records for polarization-sensitive swept-source optical

  1. All fiber optics circular-state swept source polarization-sensitive optical coherence tomography.

    Science.gov (United States)

    Lin, Hermann; Kao, Meng-Chun; Lai, Chih-Ming; Huang, Jyun-Cin; Kuo, Wen-Chuan

    2014-02-01

    A swept source (SS)-based circular-state (CS) polarization-sensitive optical coherence tomography (PS-OCT) constructed entirely with polarization-maintaining fiber optics components is proposed with the experimental verification. By means of the proposed calibration scheme, bulk quarter-wave plates can be replaced by fiber optics polarization controllers to, therefore, realize an all-fiber optics CS SSPS-OCT. We also present a numerical dispersion compensation method, which can not only enhance the axial resolution, but also improve the signal-to-noise ratio of the images. We demonstrate that this compact and portable CS SSPS-OCT system with an accuracy comparable to bulk optics systems requires less stringent lens alignment and can possibly serve as a technology to realize PS-OCT instrument for clinical applications (e.g., endoscopy). The largest deviations in the phase retardation (PR) and fast-axis (FA) angle due to sample probe in the linear scanning and a rotation angle smaller than 65 deg were of the same order as those in stationary probe setups. The influence of fiber bending on the measured PR and FA is also investigated. The largest deviations of the PR were 3.5 deg and the measured FA change by ~12 to 21 deg. Finally, in vivo imaging of the human fingertip and nail was successfully demonstrated with a linear scanning probe.

  2. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography.

    Science.gov (United States)

    Lu, Zenghai; Kasaragod, Deepa K; Matcher, Stephen J

    2011-02-21

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincaré sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  3. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lu Zenghai; Kasaragod, Deepa K; Matcher, Stephen J, E-mail: z.lu@sheffield.ac.uk, E-mail: s.j.matcher@sheffield.ac.uk [Department of Materials Science and Engineering, Kroto Research Institute, University of Sheffield, North Campus, Broad Lane, Sheffield, S3 7HQ (United Kingdom)

    2011-02-21

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincare sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  4. Multifunctional in vivo imaging for monitoring wound healing using swept-source polarization-sensitive optical coherence tomography.

    Science.gov (United States)

    Park, Kwan S; Choi, Woo June; Song, Shaozhen; Xu, Jingjiang; Wang, Ruikang K

    2017-11-30

    Wound healing involves a complex and dynamic biological process in response to tissue injury. Monitoring of the cascade of cellular events is useful for wound management and treatment. The aim of this study is to demonstrate the potential of multifunctional polarization-sensitive optical coherence tomography (PS-OCT) to longitudinally monitor the self-healing process in a murine cutaneous wound model. A multi-functional PS-OCT system based on swept source OCT configuration (1,310 nm central wavelength) was designed to obtain simultaneously microstructural, blood perfusion, and birefringent information of a biological tissue in vivo. A 1-mm-diameter wound was generated in a mouse pinna with a complete biopsy punch. Afterwards, the self-healing process of the injured tissue was observed every week over 6-week period using the multifunctional system to measure changes in the tissue birefringence. Further OCT angiography (OCTA) was used in post data processing to obtain blood perfusion information over the injured tissue. Three complementary images indicating the changes in anatomical, vascular, and birefringent information of tissue around wound were simultaneously provided from a 3-dimensional (3-D) PS-OCT data set during the wound repair over 1 month. Specifically, inflammatory and proliferative phases of wound healing were characterized by thickened epidermal tissue (from OCT images) and angiogenesis (from OCT angiography images) around wound. Also, it was observed that the regenerating tissues had highly realigned birefringent structures (from PS-OCT images). This preliminary study suggests that the proposed multi-functional imaging modality has a great potential to improve the understanding of wound healing through non-invasive, serial monitoring of vascular and tissue responses to injury. Lasers Surg. Med. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. Depth-encoded all-fiber swept source polarization sensitive OCT

    Science.gov (United States)

    Wang, Zhao; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Lee, ByungKun; Choi, WooJhon; Potsaid, Benjamin; Liu, Jonathan; Jayaraman, Vijaysekhar; Cable, Alex; Kraus, Martin F.; Liang, Kaicheng; Hornegger, Joachim; Fujimoto, James G.

    2014-01-01

    Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of conventional OCT and can assess depth-resolved tissue birefringence in addition to intensity. Most existing PS-OCT systems are relatively complex and their clinical translation remains difficult. We present a simple and robust all-fiber PS-OCT system based on swept source technology and polarization depth-encoding. Polarization multiplexing was achieved using a polarization maintaining fiber. Polarization sensitive signals were detected using fiber based polarization beam splitters and polarization controllers were used to remove the polarization ambiguity. A simplified post-processing algorithm was proposed for speckle noise reduction relaxing the demand for phase stability. We demonstrated systems design for both ophthalmic and catheter-based PS-OCT. For ophthalmic imaging, we used an optical clock frequency doubling method to extend the imaging range of a commercially available short cavity light source to improve polarization depth-encoding. For catheter based imaging, we demonstrated 200 kHz PS-OCT imaging using a MEMS-tunable vertical cavity surface emitting laser (VCSEL) and a high speed micromotor imaging catheter. The system was demonstrated in human retina, finger and lip imaging, as well as ex vivo swine esophagus and cardiovascular imaging. The all-fiber PS-OCT is easier to implement and maintain compared to previous PS-OCT systems and can be more easily translated to clinical applications due to its robust design. PMID:25401008

  6. Functional swept source optical coherence tomography

    International Nuclear Information System (INIS)

    Blatter, C.

    2013-01-01

    Optical coherence tomography (OCT) is a non-invasive imaging modality capable of providing information about a sample structure along the three spatial dimensions with micrometer scale resolution. A new chapter opened with the development of functional OCT that provides additional information to the standard structural imaging. Among those extensions is Doppler OCT (D-OCT) that yields knowledge about the motion of the sample and/or its substructure. Its main application in biomedical imaging is the assessment of blood flow. D-OCT is therefore often associated with blood velocity measurement and recently with the visualization of the vascular network. Blood flow and vasculature are important markers of tissue health. Their assessment provides crucial information for diagnostics, treatment planning and monitoring. OCT is in a good position, as a non-invasive technique, to become an alternative to current fluorescence based techniques, allowing thereby also more frequent examination and broader screenings and, as a high resolution modality, to give insight into potential changes at the capillary level. An important challenge of in vivo imaging is patient motion that decreases the quality of acquisitions. One solution to that issue is high-speed imaging. Recently swept source OCT (SSOCT) revealed to be an efficient technology to achieve high-speed. This thesis investigates the use of swept sources for qualitative and quantitative vasculature imaging. It is presented via five journal papers that form its backbone. Prior to that, main concepts of FDOCT, D-OCT and SS systems are presented. The first paper reports a SSOCT system for skin imaging. In standard OCT systems, improving the lateral resolution comes at a cost of reduced depth of focus. This should be avoided in order to be able to assess different vascular beds in depth while keeping the speed advantage of FDOCT. Employing a Bessel beam for illumination of the sample allows circumventing this issue. The image

  7. Assessing embryo development using swept source optical coherence tomography

    Science.gov (United States)

    Caujolle, S.; Cernat, R.; Silvestri, G.; Marques, M. J.; Bradu, A.; Feuchter, T.; Robinson, G.; Griffin, D.; Podoleanu, A.

    2018-03-01

    A detailed assessment of embryo development would assist biologists with selecting the most suitable embryos for transfer leading to higher pregnancy rates. Currently, only low resolution microscopy is employed to perform this assessment. Although this method delivers some information on the embryo surface morphology, no specific details are shown related to its inner structure. Using a Master-Slave Swept-Source Optical Coherence Tomography (SS-OCT), images of bovine embryos from day 7 after fertilization were collected from different depths. The dynamic changes inside the embryos were examined, in detail and in real-time from several depths. To prove our ability to characterize the morphology, a single embryo was imaged over 26 hours. The embryo was deprived of its life support environment, leading to its death. Over this period, clear morphological changes were observed.

  8. Simple and versatile long range swept source for optical coherence tomography applications

    International Nuclear Information System (INIS)

    Bräuer, Bastian; Lippok, Norman; Murdoch, Stuart G; Vanholsbeeck, Frédérique

    2015-01-01

    We present a versatile long coherence length swept-source laser design for optical coherence tomography applications. This design consists of a polygonal spinning mirror and an optical gain chip in a modified Littman–Metcalf cavity. A narrowband intra-cavity filter is implemented through multiple passes off a diffraction grating set at grazing incidence. The key advantage of this design is that it can be readily adapted to any wavelength regions for which broadband gain chips are available. We demonstrate this by implementing sources at 1650 nm, 1550 nm, 1310 nm and 1050 nm. In particular, we present a 1310 nm swept source laser with 24 mm coherence length, 95 nm optical bandwidth, 2 kHz maximum sweep frequency and 7.5 mW average output power. These parameters make it a suitable source for the imaging of biological samples. (paper)

  9. Imaging choroidal neovascular membrane using en face swept-source optical coherence tomography angiography

    Directory of Open Access Journals (Sweden)

    Moussa M

    2017-10-01

    Full Text Available Magdy Moussa,1,2 Mahmoud Leila,3 Hagar Khalid1,2 1Ophthalmology Department, Faculty of Medicine, Tanta University, Tanta, Egypt; 2MEDIC Eye Center, Tanta, Egypt; 3Retina Department, Research Institute of Ophthalmology, Giza, Egypt Purpose: The aim of this study was to assess the efficacy of swept-source optical coherence tomography angiography (SS-OCTA in delineating the morphology of choroidal neovascular membrane (CNV. Patients and methods: This was a retrospective observational case series reviewing clinical data and fundus fluorescein angiography (FFA, swept-source optical coherence tomography (SS-OCT, and SS-OCTA images of patients with CNV and comparing the findings. The swept-source technology enables deeper penetration and superior axial resolution. The incorporated blood flow detection algorithm, optical coherence tomography angiography ratio analysis (OCTARA, enables visualization of CNV in vivo without the need for dye injection. Results: The study included 136 eyes of 105 patients. Active lesions on SS-OCTA images showed increased capillary density, extensive arborization, vascular anastomosis and looping, and peri-lesional hollow. Inactive lesions showed decreased capillary density, presence of large linear vessels, and presence of feeder vessels supplying the CNV. We detected positive correlation between SS-OCTA, FFA, and SS-OCT images in 97% of eyes. In the remaining 3%, SS-OCTA confirmed the absence of CNV, whereas FFA and SS-OCT either were inconclusive in the diagnosis of CNV or yielded false-positive results. Conclusion: SS-OCT and SS-OCTA represent a reproducible risk-free analog for FFA in imaging CNV. SS-OCTA is particularly versatile in cases where FFA and SS-OCT are inconclusive. Keywords: swept-source OCT, OCT angiography, imaging of CNV, OCTARA algorithm

  10. Noninvasive Visualization and Analysis of the Human Parafoveal Capillary Network Using Swept Source OCT Optical Microangiography.

    Science.gov (United States)

    Kuehlewein, Laura; Tepelus, Tudor C; An, Lin; Durbin, Mary K; Srinivas, Sowmya; Sadda, Srinivas R

    2015-06-01

    We characterized the foveal avascular zone (FAZ) and the parafoveal capillary network in healthy subjects using swept source OCT optical microangiography (OMAG). We acquired OMAG images of the macula of 19 eyes (13 healthy individuals) using a prototype swept source laser OCT. En face images of the retinal vasculature were generated for superficial and deep inner retinal layers (SRL/DRL) in regions of interest 250 (ROI-250) and 500 (ROI-500) μm from the FAZ border. The mean area (mm2) of the FAZ was 0.304 ± 0.132 for the SRL and 0.486 ± 0.162 for the DRL (P network at different retinal layers.

  11. Swept-Source Optical Coherence Tomography Angio™ (Topcon Corp, Japan): Technology Review.

    Science.gov (United States)

    Stanga, Paulo E; Tsamis, Emmanouil; Papayannis, Alessandro; Stringa, Francesco; Cole, Tim; Jalil, Assad

    2016-01-01

    Optical coherence tomography (OCT) angiography (OCTA) is a novel, noninvasive, three-dimensional imaging technique that allows for the visualization of intravascular flow in the microvasculature. Swept-source OCT technology utilizes longer-wavelength infrared light than conventional spectral-domain OCT. This enables improved penetration into tissue and imaging through optical opacities and is invisible to the subject. Topcon has recently developed an innovative OCTA algorithm, OCTARA (OCTA Ratio Analysis), which benefits from being paired with swept-source OCT. OCTARA aims to provide improved detection sensitivity of low blood flow and reduced motion artifacts without compromising axial resolution. In this chapter, we describe the implementation of OCTARA with swept-source OCT technology, the technical specifications of acquisition (e.g. the number of scans, area of examination field, etc.) along with the algorithm's function and principles for analysis of B-scan data to achieve angiographic visualization. Examples of OCTA scans performed using the OCTARA algorithm and a comparison of these scans with images obtained using other technologies are also presented. © 2016 S. Karger AG, Basel.

  12. Swept source optical coherence microscopy using a Fourier domain mode-locked laser.

    Science.gov (United States)

    Huang, Shu-Wei; Aguirre, Aaron D; Huber, Robert A; Adler, Desmond C; Fujimoto, James G

    2007-05-14

    Swept source optical coherence microscopy (OCM) enables cellular resolution en face imaging as well as integration with optical coherence tomography (OCT) cross sectional imaging. A buffered Fourier domain mode-locked (FDML) laser light source provides high speed, three dimensional imaging. Image resolutions of 1.6 microm x 8 microm (transverse x axial) with a 220 microm x 220 microm field of view and sensitivity higher than 98 dB are achieved. Three dimensional cellular imaging is demonstrated in vivo in the Xenopus laevis tadpole and ex vivo in the rat kidney and human colon.

  13. Long axial imaging range using conventional swept source lasers in optical coherence tomography via re-circulation loops

    Science.gov (United States)

    Bradu, Adrian; Jackson, David A.; Podoleanu, Adrian

    2018-03-01

    Typically, swept source optical coherence tomography (SS-OCT) imaging instruments are capable of a longer axial range than their camera based (CB) counterpart. However, there are still various applications that would take advantage for an extended axial range. In this paper, we propose an interferometer configuration that can be used to extend the axial range of the OCT instruments equipped with conventional swept-source lasers up to a few cm. In this configuration, the two arms of the interferometer are equipped with adjustable optical path length rings. The use of semiconductor optical amplifiers in the two rings allows for compensating optical losses hence, multiple paths depth reflectivity profiles (Ascans) can be combined axially. In this way, extremely long overall axial ranges are possible. The use of the recirculation loops produces an effect equivalent to that of extending the coherence length of the swept source laser. Using this approach, the achievable axial imaging range in SS-OCT can reach values well beyond the limit imposed by the coherence length of the laser, to exceed in principle many centimeters. In the present work, we demonstrate axial ranges exceeding 4 cm using a commercial swept source laser and reaching 6 cm using an "in-house" swept source laser. When used in a conventional set-up alone, both these lasers can provide less than a few mm axial range.

  14. Dual-Source Swept-Source Optical Coherence Tomography Reconstructed on Integrated Spectrum

    Directory of Open Access Journals (Sweden)

    Shoude Chang

    2012-01-01

    Full Text Available Dual-source swept-source optical coherence tomography (DS-SSOCT has two individual sources with different central wavelengths, linewidth, and bandwidths. Because of the difference between the two sources, the individually reconstructed tomograms from each source have different aspect ratio, which makes the comparison and integration difficult. We report a method to merge two sets of DS-SSOCT raw data in a common spectrum, on which both data have the same spectrum density and a correct separation. The reconstructed tomographic image can seamlessly integrate the two bands of OCT data together. The final image has higher axial resolution and richer spectroscopic information than any of the individually reconstructed tomography image.

  15. Defect inspection of actuator lenses using swept-source optical coherence tomography

    Science.gov (United States)

    Lee, Jaeyul; Shirazi, Muhammad Faizan; Park, Kibeom; Jeon, Mansik; Kim, Jeehyun

    2017-12-01

    Actuator lens industries have gained an enormous interest with the enhancement of various latest communication devices, such as mobile phone and notebooks. The quality of the aforementioned devices can be degraded due to the internal defects of actuator lenses. Therefore, in this study, we implemented swept-source optical coherence tomography (SS-OCT) system to inspect defects of actuator lenses. Owing to the high-resolution of the SS-OCT system, defected foreign substances between the actuator lenses, defective regions of lenses and surface stains were more clearly distinguished through three-dimensional (3D) and two-dimensional (2D) cross-sectional OCT images. Therefore, the implemented SS-OCT system can be considered as a potential application to defect inspection of actuator lens.

  16. Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror

    Science.gov (United States)

    Wang, Donglin; Fu, Linlai; Wang, Xin; Gong, Zhongjian; Samuelson, Sean; Duan, Can; Jia, Hongzhi; Ma, Jun Shan; Xie, Huikai

    2013-08-01

    A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8 mm2 mirror plate and a 1.6×1.4 mm2 device footprint. The diameter of the endoscopic probe is only 3.5 mm. The imaging rate of the SS-OCT system is 50 frames/s. OCT images of both human suspicious oral leukoplakia tissue and normal buccal mucosa were taken in vivo and compared. The OCT imaging result agrees well with the histopathological analysis.

  17. Swept Source Optical Coherence Tomography Angiography for Contact Lens-Related Corneal Vascularization

    Directory of Open Access Journals (Sweden)

    Marcus Ang

    2016-01-01

    Full Text Available Purpose. To describe a novel technique of adapting a swept-source optical coherence tomography angiography (OCTA to image corneal vascularization. Methods. In this pilot cross-sectional study, we obtained 3 × 3 mm scans, where 100,000 A-scans are acquired per second with optical axial resolution of 8 μm and lateral resolution of 20 μm. This was performed with manual “XYZ” focus without the anterior segment lens, until the focus of the corneoscleral surface was clearly seen and the vessels of interest were in focus on the corresponding red-free image. En face scans were evaluated based on image quality score and repeatability. Results. We analyzed scans from 10 eyes (10 patients with corneal vascularization secondary to contact lens use in 4 quadrants, with substantial repeatability of scans in all quadrants (mean image quality score 2.7 ± 0.7; κ=0.75. There was no significant difference in image quality scores comparing quadrants (superior temporal: 2.9 ± 0.6, superior nasal: 2.8 ± 0.4, inferior temporal: 2.5 ± 0.9, and inferior nasal: 2.4 ± 1.0; P=0.276 and able to differentiate deep and superficial corneal vascularization. Conclusion. This early clinical study suggests that the swept-source OCTA used may be useful for examining corneal vascularization, which may have potential for clinical applications such as detecting early limbal stem cell damage.

  18. MULTIMODALITY IMAGING OF TORPEDO MACULOPATHY WITH SWEPT-SOURCE, EN FACE OPTICAL COHERENCE TOMOGRAPHY AND OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    Science.gov (United States)

    Papastefanou, Vasilios P; Vázquez-Alfageme, Clara; Keane, Pearse A; Sagoo, Mandeep S

    2016-10-19

    Multimodality image analysis of two cases of torpedo maculopathy. Imaging with fundus photography, autofluorescence (AF), swept-source optical coherence tomography (OCT), en face OCT, and OCT angiography. The basal diameter of the torpedo lesions was 1 mm × 2 mm. One case had a satellite lesion. Autofluorescence indicated variable loss of signal. Swept-source OCT and en face OCT demonstrated fundus excavation, attenuation of nuclear layers and disruption of the outer plexiform layer, loss of photoreceptors and a subretinal cleft. In one case, Sattler layer appeared extended at the cleft. Optical coherence tomography angiography indicated loss of flow in deep retinal vessels and increased flow in choroidal vessels surrounding the cleft. Multimodal imaging findings of torpedo maculopathy include disruption of the deep retinal capillary network, expansion of Sattler layer, and increased signal around the subretinal cleft.

  19. VISUALIZATION FROM INTRAOPERATIVE SWEPT-SOURCE MICROSCOPE-INTEGRATED OPTICAL COHERENCE TOMOGRAPHY IN VITRECTOMY FOR COMPLICATIONS OF PROLIFERATIVE DIABETIC RETINOPATHY.

    Science.gov (United States)

    Gabr, Hesham; Chen, Xi; Zevallos-Carrasco, Oscar M; Viehland, Christian; Dandrige, Alexandria; Sarin, Neeru; Mahmoud, Tamer H; Vajzovic, Lejla; Izatt, Joseph A; Toth, Cynthia A

    2018-01-10

    To evaluate the use of live volumetric (4D) intraoperative swept-source microscope-integrated optical coherence tomography in vitrectomy for proliferative diabetic retinopathy complications. In this prospective study, we analyzed a subgroup of patients with proliferative diabetic retinopathy complications who required vitrectomy and who were imaged by the research swept-source microscope-integrated optical coherence tomography system. In near real time, images were displayed in stereo heads-up display facilitating intraoperative surgeon feedback. Postoperative review included scoring image quality, identifying different diabetic retinopathy-associated pathologies and reviewing the intraoperatively documented surgeon feedback. Twenty eyes were included. Indications for vitrectomy were tractional retinal detachment (16 eyes), combined tractional-rhegmatogenous retinal detachment (2 eyes), and vitreous hemorrhage (2 eyes). Useful, good-quality 2D (B-scans) and 4D images were obtained in 16/20 eyes (80%). In these eyes, multiple diabetic retinopathy complications could be imaged. Swept-source microscope-integrated optical coherence tomography provided surgical guidance, e.g., in identifying dissection planes under fibrovascular membranes, and in determining residual membranes and traction that would benefit from additional peeling. In 4/20 eyes (20%), acceptable images were captured, but they were not useful due to high tractional retinal detachment elevation which was challenging for imaging. Swept-source microscope-integrated optical coherence tomography can provide important guidance during surgery for proliferative diabetic retinopathy complications through intraoperative identification of different complications and facilitation of intraoperative decision making.

  20. Polarization sensitive optical coherence tomography detection method

    International Nuclear Information System (INIS)

    Colston, B W; DaSilva, L B; Everett, M J; Featherstone, J D B; Fried, D; Ragadio, J N; Sathyam, U S.

    1999-01-01

    This study demonstrates the potential of polarization sensitive optical coherence tomography (PS-OCT) for non-invasive in vivo detection and characterization of early, incipient caries lesions. PS-OCT generates cross-sectional images of biological tissue while measuring the effect of the tissue on the polarization state of incident light. Clear discrimination between regions of normal and demineralized enamel is first shown in PS-OCT images of bovine enamel blocks containing well-characterized artificial lesions. High-resolution, cross-sectional images of extracted human teeth are then generated that clearly discriminate between the normal and carious regions on both the smooth and occlusal surfaces. Regions of the teeth that appeared to be demineralized in the PS-OCT images were verified using histological thin sections examined under polarized light microscopy. The PS-OCT system discriminates between normal and carious regions by measuring the polarization state of the back-scattered 1310 nm light, which is affected by the state of demineralization of the enamel. Demineralization of enamel increases the scattering coefficient, thus depolarizing the incident light. This study shows that PS-OCT has great potential for the detection, characterization, and monitoring of incipient caries lesions

  1. Volumetric cutaneous microangiography of human skin in vivo by VCSEL swept-source optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Woo June Choi; Wang, R K [University of Washington, Department of Bioengineering, Seattle, Washington 98195 (United States)

    2014-08-31

    We demonstrate volumetric cutaneous microangiography of the human skin in vivo that utilises 1.3-μm high-speed sweptsource optical coherence tomography (SS-OCT). The swept source is based on a micro-electro-mechanical (MEMS)-tunable vertical cavity surface emission laser (VCSEL) that is advantageous in terms of long coherence length over 50 mm and 100 nm spectral bandwidth, which enables the visualisation of microstructures within a few mm from the skin surface. We show that the skin microvasculature can be delineated in 3D SS-OCT images using ultrahigh-sensitive optical microangiography (UHS-OMAG) with a correlation mapping mask, providing a contrast enhanced blood perfusion map with capillary flow sensitivity. 3D microangiograms of a healthy human finger are shown with distinct cutaneous vessel architectures from different dermal layers and even within hypodermis. These findings suggest that the OCT microangiography could be a beneficial biomedical assay to assess cutaneous vascular functions in clinic. (laser biophotonics)

  2. Detection of occlusal caries in primary teeth using swept source optical coherence tomography

    Science.gov (United States)

    Nakajima, Yukie; Shimada, Yasushi; Sadr, Alireza; Wada, Ikumi; Miyashin, Michiyo; Takagi, Yuzo; Tagami, Junji; Sumi, Yasunori

    2014-01-01

    This study aimed to investigate swept source optical coherence tomography (SS-OCT) as a detecting tool for occlusal caries in primary teeth. At the in vitro part of the study, 38 investigation sites of occlusal fissures (noncavitated and cavitated) were selected from 26 extracted primary teeth and inspected visually using conventional dental equipment by six examiners without any magnification. SS-OCT cross-sectional images at 1330-nm center wavelength were acquired on the same locations. The teeth were then sectioned at the investigation site and directly viewed under a confocal laser scanning microscope (CLSM) by two experienced examiners. The presence and extent of caries were scored in each observation. The results obtained from SS-OCT and conventional visual inspections were compared with those of CLSM. Consequently, SS-OCT could successfully detect both cavitated and noncavitated lesions. The magnitude of sensitivity for SS-OCT was higher than those for visual inspection (sensitivity of visual inspection and SS-OCT, 0.70 versus 0.93 for enamel demineralization, 0.49 versus 0.89 for enamel cavitated caries, and 0.36 versus 0.75 for dentin caries). Additionally, occlusal caries of a few clinical cases were observed using SS-OCT in vivo. The results indicate that SS-OCT has a great detecting potential for occlusal caries in primary teeth.

  3. Evaluation of Anterior Chamber Volume in Cataract Patients with Swept-Source Optical Coherence Tomography.

    Science.gov (United States)

    He, Wenwen; Zhu, Xiangjia; Wolff, Don; Zhao, Zhennan; Sun, Xinghuai; Lu, Yi

    2016-01-01

    Purpose. To evaluate the anterior chamber volume in cataract patients with Swept-Source Optical Coherence Tomography (SS-OCT) and its influencing factors. Methods. Anterior chamber volume of 92 cataract patients was evaluated with SS-OCT in this cross-sectional study. Univariate analyses and multiple linear regression were used to investigate gender, age, operated eye, posterior vitreous detachment, lens opacity grading, and axial length (AXL) related variables capable of influencing the ACV. Results. The average ACV was 139.80 ± 38.21 mm(3) (range 59.41 to 254.09 mm(3)). The average ACV was significantly larger in male patients than in female patients (P = 0.001). ACV was negatively correlated with age and LOCS III cortical (C) grading of the lens (Pearson's correlation analysis, r = -0.443, P ACV was also increased with AXL (Pearson's correlation analysis, r = 0.552, P ACV (F = 10.252  P ACV varied significantly among different subjects. Influencing factors that contribute to reduced ACV were female gender, increased age, LOCS III C grade, and shorter AXL.

  4. Speckle reduction in swept source optical coherence tomography images with slow-axis averaging

    Science.gov (United States)

    Tan, Ou; Li, Yan; Wang, Yimin; Kraus, Martin F.; Liu, Jonathan J.; Potsaid, Benjamin; Baumann, Bernhard; Fujimoto, James G.; Huang, David

    2012-01-01

    The effectiveness of speckle reduction using traditional frame averaging technique was limited in ultrahigh speed optical coherence tomography (OCT). As the motion between repeated frames was very small, the speckle pattern of the frames might be identical. This problem could be solved by averaging frames acquired at slightly different locations. The optimized scan range depended on the spot size of the laser beam, the smoothness of the boundary, and the homogeneity of the tissue. In this study we presented a method to average frames obtained within a narrow range along the slow-axis. A swept-source OCT with 100,000 Hz axial scan rate was used to scan the retina in vivo. A series of narrow raster scans (0-50 micron along the slow axis) were evaluated. Each scan contained 20 image frames evenly distributed in the scan range. The imaging frame rate was 417 HZ. Only frames with high correlation after rigid registration were used in averaging. The result showed that the contrast-to-noise ratio (CNR) increased with the scan range. But the best edge reservation was obtained with 15 micron scan range. Thus, for ultrahigh speed OCT systems, averaging frames from a narrow band along the slow-axis could achieve better speckle reduction than traditional frame averaging techniques.

  5. Longitudinal study of arteriogenesis with swept source optical coherence tomography and hyperspectral imaging

    Science.gov (United States)

    Poole, Kristin M.; Patil, Chetan A.; Nelson, Christopher E.; McCormack, Devin R.; Madonna, Megan C.; Duvall, Craig L.; Skala, Melissa C.

    2014-03-01

    Peripheral arterial disease (PAD) is an atherosclerotic disease of the extremities that leads to high rates of myocardial infarction and stroke, increased mortality, and reduced quality of life. PAD is especially prevalent in diabetic patients, and is commonly modeled by hind limb ischemia in mice to study collateral vessel development and test novel therapies. Current techniques used to assess recovery cannot obtain quantitative, physiological data non-invasively. Here, we have applied hyperspectral imaging and swept source optical coherence tomography (OCT) to study longitudinal changes in blood oxygenation and vascular morphology, respectively, intravitally in the diabetic mouse hind limb ischemia model. Additionally, recommended ranges for controlling physiological variability in blood oxygenation with respect to respiration rate and body core temperature were determined from a control animal experiment. In the longitudinal study with diabetic mice, hyperspectral imaging data revealed the dynamics of blood oxygenation recovery distally in the ischemic footpad. In diabetic mice, there is an early increase in oxygenation that is not sustained in the long term. Quantitative analysis of vascular morphology obtained from Hessian-filtered speckle variance OCT volumes revealed temporal dynamics in vascular density, total vessel length, and vessel diameter distribution in the adductor muscle of the ischemic limb. The combination of hyperspectral imaging and speckle variance OCT enabled acquisition of novel functional and morphological endpoints from individual animals, and provides a more robust platform for future preclinical evaluations of novel therapies for PAD.

  6. Swept source optical coherence tomography for quantitative and qualitative assessment of dental composite restorations

    Science.gov (United States)

    Sadr, Alireza; Shimada, Yasushi; Mayoral, Juan Ricardo; Hariri, Ilnaz; Bakhsh, Turki A.; Sumi, Yasunori; Tagami, Junji

    2011-03-01

    The aim of this work was to explore the utility of swept-source optical coherence tomography (SS-OCT) for quantitative evaluation of dental composite restorations. The system (Santec, Japan) with a center wavelength of around 1300 nm and axial resolution of 12 μm was used to record data during and after placement of light-cured composites. The Fresnel phenomenon at the interfacial defects resulted in brighter areas indicating gaps as small as a few micrometers. The gap extension at the interface was quantified and compared to the observation by confocal laser scanning microscope after trimming the specimen to the same cross-section. Also, video imaging of the composite during polymerization could provide information about real-time kinetics of contraction stress and resulting gaps, distinguishing them from those gaps resulting from poor adaptation of composite to the cavity prior to polymerization. Some samples were also subjected to a high resolution microfocus X-ray computed tomography (μCT) assessment; it was found that differentiation of smaller gaps from the radiolucent bonding layer was difficult with 3D μCT. Finally, a clinical imaging example using a newly developed dental SS-OCT system with an intra-oral scanning probe (Panasonic Healthcare, Japan) is presented. SS-OCT is a unique tool for clinical assessment and laboratory research on resin-based dental restorations. Supported by GCOE at TMDU and NCGG.

  7. The advantages of a swept source optical coherence tomography system in the evaluation of occlusal disorders

    Science.gov (United States)

    Marcauteanu, Corina; Bradu, Adrian; Sinescu, Cosmin; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Duma, Virgil Florin; Podoleanu, Adrian Gh.

    2014-01-01

    Occlusal disorders are characterized by multiple dental and periodontal signs. Some of these are reversible (such as excessive tooth mobility, fremitus, tooth pain, migration of teeth in the absence of periodontitis), some are not (pathological occlusal/incisal wear, abfractions, enamel cracks, tooth fractures, gingival recessions). In this paper we prove the advantages of a fast swept source OCT system in the diagnosis of pathological incisal wear, a key sign of the occlusal disorders. On 15 extracted frontal teeth four levels of pathological incisal wear facets were artificially created. After every level of induced defect, OCT scanning was performed. B scans were acquired and 3D reconstructions were generated. A swept source OCT instrument is used in this study. The swept source is has a central wavelength of 1050 nm and a sweeping rate of 100 kHz. A depth resolution determined by the swept source of 12 μm in air was experimentally measured. The pathological incisal wear is qualitatively observed on the B-scans as 2D images and 3D reconstructions (volumes). For quantitative evaluations of volumes, we used the Image J software. Our swept source OCT system has several advantages, including the ability to measure (in air) a minimal volume of 2352 μm3 and to collect high resolution volumetric images in 2.5 s. By calculating the areas of the amount of lost tissue corresponding to each difference of B-scans, the final volumes of incisal wear were obtained. This swept source OCT method is very useful for the dynamic evaluation of pathological incisal wear.

  8. High-speed cross-sectional imaging of valuable documents using common-path swept-source optical coherence tomography.

    Science.gov (United States)

    Fujiwara, Kazuo; Matoba, Osamu

    2011-12-01

    A common-path swept-source optical coherence tomography (SS-OCT) is a promising scheme for implementing a high-speed and stable OCT system. We investigate the capability of a common-path SS-OCT system to perform the cross-sectional imaging of valuable documents translated at high speed for the check of its security feature. The influence of transport speeds, up to 2000 mm/s, on the depth resolution and the signal intensity is experimentally evaluated using a SS-OCT system equipped with a swept source at a center wavelength of 1335 nm and with a sweep repetition rate of 50 kHz. The degradation of the measured signal is in good agreement with theory. © 2011 Optical Society of America

  9. Evaluation of focal choroidal excavation in the macula using swept-source optical coherence tomography

    Science.gov (United States)

    Lim, F P M; Loh, B K; Cheung, C M G; Lim, L S; Chan, C M; Wong, D W K

    2014-01-01

    Purpose To evaluate imaging findings of patients with focal choroidal excavation (FCE) in the macula using swept-source optical coherence tomography (SS-OCT) and correlate it clinically. Methods Prospective observational case series. Eleven consecutive patients (12 eyes) with FCE were described. Data on demographics and clinical presentation were collected and imaging findings (including color photography, fundus autofluorescence imaging, fluorescein angiography, indocyanine green angiography, spectral-domain optical coherence tomography, and SS-OCT) were analyzed. Results The primary diagnosis was epiretinal membrane (two eyes), choroidal neovascularization (one eye), polypoidal choroidal vasculopathy (three eyes), central serous chorioretinopathy (one eye), and dry age-related macular degeneration (two eyes). Eleven out of 12 of the lesions were conforming. One presented with a non-conforming lesion that progressed to a conforming lesion. One eye had multiFCE and two had two overlapping choroidal excavations. Using the SS-OCT, we found the choroid to be thinned out at the area of FCE but sclera remained normal. The choroidal tissue beneath the FCE was abnormal, with high internal reflectivity and poor visualization of choroidal vessels. There was loss of contour of the outer choroidal boundary that appeared to be pulled inward by this abnormal choroidal tissue. A suprachoroidal space was noted beneath this choroidal tissue and the choroidal–scleral interface was smooth. Repeat SS-OCT 6 months after presentation showed the area of excavation to be stable in size. Conclusion FCE can be associated with epiretinal membrane, central serous chorioretinopathy, and age-related macular degeneration. The choroid was thinned out in the area of FCE. PMID:24946847

  10. Macular retinal and choroidal thickness in unilateral amblyopia using swept-source optical coherence tomography.

    Science.gov (United States)

    Araki, Syunsuke; Miki, Atsushi; Goto, Katsutoshi; Yamashita, Tsutomu; Takizawa, Go; Haruishi, Kazuko; Ieki, Yoshiaki; Kiryu, Junichi; Yaoeda, Kiyoshi

    2017-09-15

    To investigate macular retinal and choroidal thickness in amblyopic eyes compared to that in fellow and normal eyes using swept-source optical coherence tomography (SS-OCT). This study examined 31 patients with hyperopic anisometropic amblyopia (6.9 ± 3.8 years, mean ± standard deviation), 15 patients with strabismic amblyopia without anisometropia (7.9 ± 4.2 years), and 24 age-matched controls (7.8 ± 3.3 years). Retinal and choroidal thickness was measured by 3D scans using SS-OCT. A 6-mm area around the fovea was automatically analyzed using the Early Treatment Diabetic Retinopathy Study map. The thickness from SS-OCT was corrected for magnification error using individual axial length, spherical refraction, cylinder refraction, and corneal radius. Retinal thickness was divided into the macular retinal nerve fiber layer (mRNFL), ganglion cell layer + inner plexiform layer (GCL+IPL), ganglion cell complex (GCC), and the inner limiting membrane to the retinal pigment epithelium (ILM-RPE) thickness. Retinal and choroidal thickness was compared among amblyopic, fellow, and normal eyes. In both amblyopia groups, there was no significant difference in the mRNFL, GCL+IPL, and GCC thicknesses among the amblyopic, fellow, and control eyes. In the anisometropic amblyopia group, choroidal thickness (subfovea, center 1 mm, nasal and inferior of the inner ring, nasal of the outer ring, and center 6 mm) of amblyopic eyes were significantly greater than that of fellow and normal eyes. In contrast, none of the choroidal thicknesses were significantly different among the investigated eyes in the strabismic amblyopia group. We found no significant difference in inner retinal thickness in patients with unilateral amblyopia. Although there were significant differences in choroidal thickness with hyperopic anisometropic amblyopia, there was no significant difference for the strabismic amblyopia. The discrepancy in choroidal thickness between the two types of amblyopia may be due

  11. Observation of the pulp horn by swept source optical coherence tomography and cone beam computed tomography

    Science.gov (United States)

    Iino, Yoshiko; Yoshioka, Toshihiko; Hanada, Takahiro; Ebihara, Arata; Sunakawa, Mitsuhiro; Sumi, Yasunori; Suda, Hideaki

    2015-02-01

    Cone-beam computed tomography (CBCT) is one of the most useful diagnostic techniques in dentistry but it involves ionizing radiation, while swept source optical coherence tomography (SS-OCT) has been introduced recently as a nondestructive, real-time, high resolution imaging technique using low-coherence interferometry, which involves no ionizing radiation. The purpose of this study was to evaluate the ability of SS-OCT to detect the pulp horn (PH) in comparison with that of CBCT. Ten extracted human mandibular molars were used. After horizontally removing a half of the tooth crown, the distance from the cut dentin surface to PH was measured using microfocus computed tomography (Micro CT) (SL) as the gold standard, by CBCT (CL) and by SS-OCT (OL). In the SS-OCT images, only when PH was observed beneath the overlying dentin, the distance from the cut dentin surface to PH was recorded. If the pulp was exposed, it was defined as pulp exposure (PE). The results obtained by the above three methods were statistically analyzed by Spearman's rank correlation coefficient at a significance level of p PH when the distance from the cut dentin surface to PH determined by SL was 2.33 mm or less. Strong correlations of the measured values were found between SL and CL (r=0.87), SL and OL (r=0.96), and CL and OL (r=0.86). The results showed that SS-OCT images correlated closely with CBCT images, suggesting that SS-OCT can be a useful tool for the detection of PH.

  12. Apices of maxillary premolars observed by swept source optical coherence tomography

    Science.gov (United States)

    Ebihara, Arata; Iino, Yoshiko; Yoshioka, Toshihiko; Hanada, Takahiro; Sunakawa, Mitsuhiro; Sumi, Yasunori; Suda, Hideaki

    2015-02-01

    Apicoectomy is performed for the management of apical periodontitis when orthograde root canal treatment is not possible or is ineffective. Prior to the surgery, cone beam computed tomography (CBCT) examination is often performed to evaluate the lesion and the adjacent tissues. During the surgical procedure, the root apex is resected and the resected surface is usually observed under dental operating microscope (DOM). However, it is difficult to evaluate the details and the subsurface structure of the root using CBCT and DOM. A new diagnostic system, swept source optical coherence tomography (SS-OCT), has been developed to observe the subsurface anatomical structure. The aim of this study was to observe resected apical root canals of human maxillary premolars using SS-OCT and compare the findings with those observed using CBCT and DOM. Six extracted human maxillary premolars were used. After microfocus computed tomography (Micro CT; for gold standard) and CBCT scanning of the root, 1 mm of the apex was cut perpendicular to the long axis of the tooth. Each resected surface was treated with EDTA, irrigated with saline solution, and stained with methylene blue dye. The resected surface was observed with DOM and SS-OCT. This sequence was repeated three times. The number of root canals was counted and statistically evaluated. There was no significant difference in the accuracy of detecting root canals among CBCT, DOM and SS-OCT (p > 0.05, Wilcoxon test). Because SS-OCT can be used in real time during surgery, it would be a useful tool for observing resected apical root canals.

  13. Macular choroidal thickness in normal Egyptians measured by swept source optical coherence tomography.

    Science.gov (United States)

    Moussa, Magdy; Sabry, Dalia; Soliman, Wael

    2016-08-05

    To provide a normal database of choroidal thickness (CT) in nine Early Treatment Diabetes Retinopathy Study (ETDRS) subfields in Egypt using deep-range imaging swept source optical coherence tomography (DRI SS OCT). This study included a total of 129 eyes of 71 normal Egyptian subjects, comprising 63 males and 66 females. The mean age was 36.85 ± 14.22 years (range, 16-67 years). The mean axial length was 23.84 ± 0.78 mm. CT was measured in nine subfields as defined by the ETDRS-style grid using a DRI SS OCT, and line measurements of subfoveal choroidal thicknesses (SFCT) were also performed. Mean SFCT was 300.87 ± 72.256 μm for ring measurements and 319.72 ± 76.45 μm for line measurements (P = 0.04). CT was higher in the superior and temporal quadrants than the inferior and nasal quadrants. A negative correlation between subfoveal choroidal thickness and age was detected in all regions (P < 0.001) except the nasal quadrant. A negative correlation between the SFCT and axial length was also detected (P < 0.001). Males tended to have a thicker choroid than females; however, the difference was not significant. DRI SS OCT provides a topographic map of choroidal thickness with an ETDRS layout. This study establishes, for the first time, a normal database for CT in the Egyptian population. Age and axial length were associated with choroidal parameters in healthy subjects. Line measurements of the SFCT differed significantly from SFCT ring measurements, so it is recommended that each method be compared independently.

  14. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes.

    Science.gov (United States)

    Jhanji, Vishal; Yang, Bingzhi; Yu, Marco; Ye, Cong; Leung, Christopher K S

    2013-11-01

    To compare corneal thickness and corneal elevation using swept source optical coherence tomography and slit scanning topography. Prospective study. 41 normal and 46 keratoconus subjects. All eyes were imaged using swept source optical coherence tomography and slit scanning tomography during the same visit. Mean corneal thickness and best-fit sphere measurements were compared between the instruments. Agreement of measurements between swept source optical coherence tomography and scanning slit topography was analyzed. Intra-rater reproducibility coefficient and intraclass correlation coefficient were evaluated. In normal eyes, central corneal thickness measured by swept source optical coherence tomography was thinner compared with slit scanning topography (p topography. In keratoconus eyes, central corneal thickness was thinner on swept source optical coherence tomography than slit scanning topography (p = 0.081) and ultrasound pachymetry (p = 0.001). There were significant differences between thinnest corneal thickness, and, anterior and posterior best-fit sphere measurements between both instruments (p topography. With better reproducibility coefficients and intraclass correlation coefficients, swept source optical coherence tomography may provide a reliable alternative for measurement of corneal parameters. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  15. Polarization-sensitive optical frequency domain imaging based on unpolarized light.

    Science.gov (United States)

    Kim, Ki Hean; Park, B Hyle; Tu, Yupeng; Hasan, Tayyaba; Lee, Byunghak; Li, Jianan; de Boer, Johannes F

    2011-01-17

    Polarization-sensitive optical coherence tomography (PS-OCT) is an augmented form of OCT, providing 3D images of both tissue structure and polarization properties. We developed a new method of polarization-sensitive optical frequency domain imaging (PS-OFDI), which is based on a wavelength-swept source. In this method the sample was illuminated with unpolarized light, which was composed of two orthogonal polarization states (i.e., separated by 180° in the Poincaré sphere) that are uncorrelated to each other. Reflection of these polarization states from within the sample was detected simultaneously and independently using a frequency multiplexing scheme. This simultaneous sample probing with two polarization states enabled determination of the depth-resolved Jones matrices of the sample. Polarization properties of the sample were obtained by analyzing the sample Jones matrices through eigenvector decomposition. The new PS-OFDI system ran at 31K wavelength-scans/s with 3072 pixels per wavelength-scan, and was tested by imaging a polarizer and several birefringent tissues such as chicken muscle and human skin. Lastly the new PS-OFDI was applied to imaging two cancer animal models: a mouse model by injecting cancer cells and a hamster cheek pouch model. These animal model studies demonstrated the significant differences in tissue polarization properties between cancer and normal tissues in vivo.

  16. Enhanced vitreous imaging in healthy eyes using swept source optical coherence tomography.

    Science.gov (United States)

    Liu, Jonathan J; Witkin, Andre J; Adhi, Mehreen; Grulkowski, Ireneusz; Kraus, Martin F; Dhalla, Al-Hafeez; Lu, Chen D; Hornegger, Joachim; Duker, Jay S; Fujimoto, James G

    2014-01-01

    To describe enhanced vitreous imaging for visualization of anatomic features and microstructures within the posterior vitreous and vitreoretinal interface in healthy eyes using swept-source optical coherence tomography (SS-OCT). The study hypothesis was that long-wavelength, high-speed, volumetric SS-OCT with software registration motion correction and vitreous window display or high-dynamic-range (HDR) display improves detection sensitivity of posterior vitreous and vitreoretinal features compared to standard OCT logarithmic scale display. Observational prospective cross-sectional study. Multiple wide-field three-dimensional SS-OCT scans (500×500A-scans over 12×12 mm2) were obtained using a prototype instrument in 22 eyes of 22 healthy volunteers. A registration motion-correction algorithm was applied to compensate motion and generate a single volumetric dataset. Each volumetric dataset was displayed in three forms: (1) standard logarithmic scale display, enhanced vitreous imaging using (2) vitreous window display and (3) HDR display. Each dataset was reviewed independently by three readers to identify features of the posterior vitreous and vitreoretinal interface. Detection sensitivities for these features were measured for each display method. Features observed included the bursa premacularis (BPM), area of Martegiani, Cloquet's/BPM septum, Bergmeister papilla, posterior cortical vitreous (hyaloid) detachment, papillomacular hyaloid detachment, hyaloid attachment to retinal vessel(s), and granular opacities within vitreous cortex, Cloquet's canal, and BPM. The detection sensitivity for these features was 75.0% (95%CI: 67.8%-81.1%) using standard logarithmic scale display, 80.6% (95%CI: 73.8%-86.0%) using HDR display, and 91.9% (95%CI: 86.6%-95.2%) using vitreous window display. SS-OCT provides non-invasive, volumetric and measurable in vivo visualization of the anatomic microstructural features of the posterior vitreous and vitreoretinal interface. The

  17. Enhanced vitreous imaging in healthy eyes using swept source optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Jonathan J Liu

    Full Text Available To describe enhanced vitreous imaging for visualization of anatomic features and microstructures within the posterior vitreous and vitreoretinal interface in healthy eyes using swept-source optical coherence tomography (SS-OCT. The study hypothesis was that long-wavelength, high-speed, volumetric SS-OCT with software registration motion correction and vitreous window display or high-dynamic-range (HDR display improves detection sensitivity of posterior vitreous and vitreoretinal features compared to standard OCT logarithmic scale display.Observational prospective cross-sectional study.Multiple wide-field three-dimensional SS-OCT scans (500×500A-scans over 12×12 mm2 were obtained using a prototype instrument in 22 eyes of 22 healthy volunteers. A registration motion-correction algorithm was applied to compensate motion and generate a single volumetric dataset. Each volumetric dataset was displayed in three forms: (1 standard logarithmic scale display, enhanced vitreous imaging using (2 vitreous window display and (3 HDR display. Each dataset was reviewed independently by three readers to identify features of the posterior vitreous and vitreoretinal interface. Detection sensitivities for these features were measured for each display method.Features observed included the bursa premacularis (BPM, area of Martegiani, Cloquet's/BPM septum, Bergmeister papilla, posterior cortical vitreous (hyaloid detachment, papillomacular hyaloid detachment, hyaloid attachment to retinal vessel(s, and granular opacities within vitreous cortex, Cloquet's canal, and BPM. The detection sensitivity for these features was 75.0% (95%CI: 67.8%-81.1% using standard logarithmic scale display, 80.6% (95%CI: 73.8%-86.0% using HDR display, and 91.9% (95%CI: 86.6%-95.2% using vitreous window display.SS-OCT provides non-invasive, volumetric and measurable in vivo visualization of the anatomic microstructural features of the posterior vitreous and vitreoretinal interface. The

  18. Polarization sensitive optical frequency domain imaging system for endobronchial imaging

    NARCIS (Netherlands)

    Li, J.; Feroldi, Fabio; de Lange, J.; Daniels, J.M.A.; Grünberg, K.; de Boer, J.F.

    2015-01-01

    A polarization sensitive endoscopic optical frequency domain imaging (PS-OFDI) system with a motorized distal scanning catheter is demonstrated. It employs a passive polarization delay unit to multiplex two orthogonal probing polarization states in depth, and a polarization diverse detection unit to

  19. Polarization sensitive optical coherence tomography in dentistry

    International Nuclear Information System (INIS)

    Dichtl, S.

    1998-01-01

    Optical coherence tomography (OCT) is a noninvasive and noncontact technique for obtaining cross-sectional images of biologic structure, which was initially introduced to depict the transparent tissue of the eye. It employs the partial coherence properties of a light source to image structures with high resolution (< 20 (m). Recently, this technique has also been applied in turbid media. This tomographic imaging is analogous to conventional ultrasound B mode imaging, except that OCT measures the intensity of backreflected infrared light rather than acoustical waves. First applications, of OCT in dentistry for diagnosing periodontal disease have been reported by Colston et al. presenting in vitro OCT images of the dental and periodontal tissues of porcine premolar teeth. In this work, the feasibility of polarisation sensitive OCT for dental material is suggested. In contrast with conventional OCT, where the magnitude of backscattered light as a function of depth is imaged, backscattered light is used to image the magnitude of the birefringence in the sample as a function of depth. Partial loss of birefringence is known to be an early indication of incipient caries or tissue thermal damage. Applying this technique for caries diagnosis or guidance regarding optimal dosimetry for thermally mediated laser therapeutic procedures, polarisation sensitive OCT would represent a promising new technology for dentistry. (author)

  20. Swept source optical coherence tomography Gabor fusion splicing technique for microscopy of thick samples using a deformable mirror.

    Science.gov (United States)

    Costa, Christopher; Bradu, Adrian; Rogers, John; Phelan, Pauline; Podoleanu, Adrian

    2015-01-01

    We present a swept source optical coherence tomography (OCT) system at 1060 nm equipped with a wavefront sensor at 830 nm and a deformable mirror in a closed-loop adaptive optics (AO) system. Due to the AO correction, the confocal profile of the interface optics becomes narrower than the OCT axial range, restricting the part of the B-scan (cross section) with good contrast. By actuating on the deformable mirror, the depth of the focus is changed and the system is used to demonstrate Gabor filtering in order to produce B-scan OCT images with enhanced sensitivity throughout the axial range from a Drosophila larvae. The focus adjustment is achieved by manipulating the curvature of the deformable mirror between two user-defined limits. Particularities of controlling the focus for Gabor filtering using the deformable mirror are presented.

  1. Increasing signal-to-noise ratio of swept-source optical coherence tomography by oversampling in k-space

    Science.gov (United States)

    Nagib, Karim; Mezgebo, Biniyam; Thakur, Rahul; Fernando, Namal; Kordi, Behzad; Sherif, Sherif

    2018-03-01

    Optical coherence tomography systems suffer from noise that could reduce ability to interpret reconstructed images correctly. We describe a method to increase the signal-to-noise ratio of swept-source optical coherence tomography (SSOCT) using oversampling in k-space. Due to this oversampling, information redundancy would be introduced in the measured interferogram that could be used to reduce white noise in the reconstructed A-scan. We applied our novel scaled nonuniform discrete Fourier transform to oversampled SS-OCT interferograms to reconstruct images of a salamander egg. The peak-signal-to-noise (PSNR) between the reconstructed images using interferograms sampled at 250MS/s andz50MS/s demonstrate that this oversampling increased the signal-to-noise ratio by 25.22 dB.

  2. Defense of fake fingerprint attacks using a swept source laser optical coherence tomography setup

    Science.gov (United States)

    Meissner, Sven; Breithaupt, Ralph; Koch, Edmund

    2013-03-01

    The most established technique for the identification at biometric access control systems is the human fingerprint. While every human fingerprint is unique, fingerprints can be faked very easily by using thin layer fakes. Because commercial fingerprint scanners use only a two-dimensional image acquisition of the finger surface, they can only hardly differentiate between real fingerprints and fingerprint fakes applied on thin layer materials. A Swept Source OCT system with an A-line rate of 20 kHz and a lateral and axial resolution of approximately 13 μm, a centre wavelength of 1320 nm and a band width of 120 nm (FWHM) was used to acquire fingerprints and finger tips with overlying fakes. Three-dimensional volume stacks with dimensions of 4.5 mm x 4 mm x 2 mm were acquired. The layering arrangement of the imaged finger tips and faked finger tips was analyzed and subsequently classified into real and faked fingerprints. Additionally, sweat gland ducts were detected and consulted for the classification. The manual classification between real fingerprints and faked fingerprints results in almost 100 % correctness. The outer as well as the internal fingerprint can be recognized in all real human fingers, whereby this was not possible in the image stacks of the faked fingerprints. Furthermore, in all image stacks of real human fingers the sweat gland ducts were detected. The number of sweat gland ducts differs between the test persons. The typical helix shape of the ducts was observed. In contrast, in images of faked fingerprints we observe abnormal layer arrangements and no sweat gland ducts connecting the papillae of the outer fingerprint and the internal fingerprint. We demonstrated that OCT is a very useful tool to enhance the performance of biometric control systems concerning attacks by thin layer fingerprint fakes.

  3. COMPARING FUNDUS FLUORESCEIN ANGIOGRAPHY AND SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN THE EVALUATION OF DIABETIC MACULAR PERFUSION.

    Science.gov (United States)

    La Mantia, Alberto; Kurt, Rengin A; Mejor, Samantha; Egan, Catherine A; Tufail, Adnan; Keane, Pearse A; Sim, Dawn A

    2018-01-16

    To compare fundus fluorescein angiography (FFA) and swept-source optical coherence tomography angiography (SS-OCTA) in the evaluation of macular perfusion in diabetic patients. Forty-one eyes (21 diabetic patients) seen at Moorfields Eye Hospital (London) over a 1-month interval underwent color fundus photography, FFA, and SS-OCTA imaging of the capillary superficial plexus using 2 different protocols: 3 × 3 mm and 4.5 × 4.5 mm. Quantitative assessment (foveal avascular zone diameters and area), qualitative analysis (macroscopic and microscopic levels) and Early Treatment Diabetic Retinopathy Study diabetic macular ischemia grading were performed. Artifacts were recorded. Intraclass correlation coefficients and weighted kappa values were calculated. Mean (SD) foveal avascular zone area was 0.695 (0.52) mm on FFA, 0.627 (0.54) mm on SS-OCTA 3 × 3 and 0.701 (0.54) mm on SS-OCTA 4.5 × 4.5 protocol. Intraclass correlation coefficients showed good agreement between FFA and SS-OCTA for both vertical diameter and foveal avascular zone area measurements. The agreement between SS-OCTA 3 × 3 and 4.5 × 4.5 was good for all quantitative measurements. Weighted kappa for diabetic macular ischemia grading showed low to fair agreement between FFA and SS-OCTA, whereas the agreement was good between two different SS-OCTA protocols. Swept-source OCTA is a reproducible technique in the assessment of macular perfusion in diabetic patients with special regards to foveal avascular zone analysis. The agreement with FFA is limited especially for diabetic macular ischemia grading. Fundus fluorescein angiography is more sensitive in identifying microaneurysms.

  4. Optimisation of a polygon mirror-based spectral filter for swept source optical coherence tomography (SS-OCT)

    Science.gov (United States)

    Everson, Michael; Duma, Virgil-Florin; Dobre, George

    2018-03-01

    Medical imaging using Optical Coherence Tomography (OCT) provides clinicians with 3D, high resolution reconstructions of microscopic structures, in depth. It has been initially developed for ophthalmology, in order to scan the retinas of patients to diagnose illness. The quality of the images depends upon their axial and lateral resolutions and the properties of the light being used. Research using a polygon mirror (PM) as a spectral filter in Swept Source OCT (SS-OCT) has resulted in a variety of different experimental arrangements. Although the application of PM-based SS-OCT sources has been successfully demonstrated, the combination of their components' fundamental properties and the overall impact they have on imaging performance is rarely reported. A more detailed examination of these properties would lead to a full description of their operation and to the best methods to employ if system performance is to be maximised. This work presents our current findings of on-going research into the optimisation of PM-based SS-OCT systems. A swept source spectral filter, consisting of a collimator, a transmission grating, a two-lens telescope and an off-axis PM with an end reflector mirror has been evaluated experimentally and compared with theoretical predictions. The system's performance has been compared for two different fibre collimators. Although the beam width on the grating is different for each of the two collimators, the spot size at the PM facet is made the same by selecting appropriate focal lengths. An improvement in the signal roll-off at the interferometer output of 1.0 dB/mm was obtained when using a 3.4 mm collimator compared to a 1.5 mm collimator.

  5. Morphological features in anterior scleral inflammation using swept-source optical coherence tomography with multiple B-scan averaging.

    Science.gov (United States)

    Kuroda, Yoshimasa; Uji, Akihito; Morooka, Satoshi; Nishijima, Kazuaki; Yoshimura, Nagahisa

    2017-04-01

    To determine the morphological features of anterior scleral inflammation using swept-source optical coherence tomography. In this retrospective observational study, we examined 17 eyes of 14 patients with diffuse anterior scleral inflammation and 13 eyes of 13 young unaffected patients. We compared cross-sectional images of the conjunctiva, episclera and sclera obtained using swept-source optical coherence tomography equipped with a multiple B-scan averaging process between normal eyes and those with episcleritis and scleritis. Optical coherence tomography showed that the conjunctival stroma/episclera layer was notably swollen in diseased eyes. The eyes with diffuse anterior scleral inflammation had a significantly thicker conjunctival stroma/episclera than normal eyes (403.0 μm vs 288.0 μm, p=0.002). There was no significant difference in scleral stroma thickness between eyes with anterior scleral inflammation and normal eyes (464.7 μm vs 434.2 μm, p=0.11). We separately analysed 11 eyes with diffuse scleritis and 6 eyes with diffuse episcleritis. While the conjunctival epithelium and conjunctival stroma/episclera were thicker in eyes with diffuse scleritis than in those with diffuse episcleritis (78.9 μm vs 50.4 μm, p=0.003 and 445.5 μm vs 308.8 μm, p=0.033, respectively), the scleral stroma thickness in eyes with diffuse scleritis was comparable with normal eyes (465.5 μm vs 434.2 μm, p=0.43). The swelling of diffuse scleritis occurred within the episclera rather than in the scleral stroma. Since optical coherence tomography visualises the morphology of the episclera and sclera, it can be useful for evaluating inflammation activity and therapeutic effects in diffuse scleritis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Simultaneous dual-wavelength-band common-path swept-source optical coherence tomography with single polygon mirror scanner.

    Science.gov (United States)

    Mao, Youxin; Chang, Shoude; Murdock, Erroll; Flueraru, Costel

    2011-06-01

    We report a novel (to the best of our knowledge) simultaneous 1310/1550 two-wavelength band swept laser source and dual-band common-path swept-source optical coherence tomography (SS-OCT). Synchronized dual-wavelength tuning is performed by using two laser cavities and narrowband wavelength filters with a single dual-window polygonal scanner. Measured average output powers of 60 and 27 mW have been achieved for the 1310 and 1550 nm bands, respectively, while the two wavelengths were swept simultaneously from 1227 to 1387 nm for the 1310 nm band and from 1519 to 1581 nm for the 1550 nm band at an A-scan rate of 65 kHz. Broadband wavelength-division multiplexing is used for coupling two wavelengths into a common-path single-mode GRIN-lensed fiber probe to form dual-band common-path SS-OCT. Simultaneous OCT imaging at 1310 and 1550 nm is achieved. This technique allows for in vivo high-speed OCT imaging with potential application in functional (spectroscopic) investigations. © 2011 Optical Society of America

  7. Advanced polarization sensitive analysis in optical coherence tomography

    Science.gov (United States)

    Wieloszyńska, Aleksandra; StrÄ kowski, Marcin R.

    2017-08-01

    The optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection. Standard OCT imaging is based on intensity images which can visualize the inner structure of scattering devices. However, there is a number of extensions improving the OCT measurement abilities. The main of them are the polarization sensitive OCT (PS-OCT), Doppler enable OCT (D-OCT) or spectroscopic OCT (S-OCT). Our research activities have been focused on PS-OCT systems. The polarization sensitive analysis delivers an useful information about optical anisotropic properties of the evaluated sample. This kind of measurements is very important for inner stress monitoring or e.g. tissue recognition. Based on our research results and knowledge the standard PS-OCT provide only data about birefringence of the measured sample. However, based on the OCT measurements more information including depolarization and diattenuation might be obtained. In our work, the method based on Jones formalism are going to be presented. It is used to determine birefringence, dichroism and optic axis orientation of the tested sample. In this contribution the setup of the optical system, as well as tests results verifying the measurements abilities of the system are going to be presented. The brief discussion about the effectiveness and usefulness of this approach will be carried out.

  8. Evaluation of retinal and choroidal thickness by swept-source optical coherence tomography: repeatability and assessment of artifacts.

    Science.gov (United States)

    Mansouri, Kaweh; Medeiros, Felipe A; Tatham, Andrew J; Marchase, Nicholas; Weinreb, Robert N

    2014-05-01

    To determine the repeatability of automated retinal and choroidal thickness measurements with swept-source optical coherence tomography (SS OCT) and the frequency and type of scan artifacts. Prospective evaluation of new diagnostic technology. Thirty healthy subjects were recruited prospectively and underwent imaging with a prototype SS OCT instrument. Undilated scans of 54 eyes of 27 subjects (mean age, 35.1 ± 9.3 years) were obtained. Each subject had 4 SS OCT protocols repeated 3 times: 3-dimensional (3D) 6 × 6-mm raster scan of the optic disc and macula, radial, and line scan. Automated measurements were obtained through segmentation software. Interscan repeatability was assessed by intraclass correlation coefficients (ICCs). ICCs for choroidal measurements were 0.92, 0.98, 0.80, and 0.91, respectively, for 3D macula, 3D optic disc, radial, and line scans. ICCs for retinal measurements were 0.39, 0.49, 0.71, and 0.69, respectively. Artifacts were present in up to 9% scans. Signal loss because of blinking was the most common artifact on 3D scans (optic disc scan, 7%; macula scan, 9%), whereas segmentation failure occurred in 4% of radial and 3% of line scans. When scans with image artifacts were excluded, ICCs for choroidal thickness increased to 0.95, 0.99, 0.87, and 0.93 for 3D macula, 3D optic disc, radial, and line scans, respectively. ICCs for retinal thickness increased to 0.88, 0.83, 0.89, and 0.76, respectively. Improved repeatability of automated choroidal and retinal thickness measurements was found with the SS OCT after correction of scan artifacts. Recognition of scan artifacts is important for correct interpretation of SS OCT measurements. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Chip Based Common-path Swept-source Optical Coherence Tomography Device

    NARCIS (Netherlands)

    Chang, Lantian

    2016-01-01

    Optical coherence tomography (OCT) is an optical imaging technique which provides three-dimensional images with micrometer-resolution. OCT has been extensively used for disease diagnostics, treatment planning, and surgical guidance. Currently, most of the OCT systems are based on discrete free-space

  10. Swept source optical coherence tomography for in vivo imaging and vibrometry in the apex of the mouse cochlea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Yoon [E.L. Ginzton Laboratory and Department of Electrical Engineering, Stanford University, Stanford, California (United States); Department of Otolaryngology-Head and Neck Surgery, Stanford University, Stanford, California (United States); Raphael, Patrick D.; Oghalai, John S. [Department of Otolaryngology-Head and Neck Surgery, Stanford University, Stanford, California (United States); Ellerbee, Audrey K. [E.L. Ginzton Laboratory and Department of Electrical Engineering, Stanford University, Stanford, California (United States); Applegate, Brian E. [Department of Biomedical Engineering, Texas A& M University, College Station, Texas (United States)

    2015-12-31

    Cochlear amplification has been most commonly investigated by measuring the vibrations of the basilar membrane in animal models. Several different techniques have been used for measuring these vibrations such as laser Doppler vibrometry, miniature pressure sensors, low coherence interferometry, and spectral-domain optical coherence tomography (SD-OCT). We have built a swept-source OCT (SS-OCT) system, which is similar to SD-OCT in that it is capable of performing both imaging and vibration measurements within the mouse cochlea in vivo without having to open the bone. In vivo 3D images of a mouse cochlea were obtained, and the basilar membrane, tectorial membrane, Reissner’s membrane, tunnel of Corti, and reticular lamina could all be resolved. We measured vibrations of multiple structures within the mouse cochlea to sound stimuli. As well, we measured the radial deflections of the reticular lamina and tectorial membrane to estimate the displacement of the outer hair cell stereocilia. These measurements have the potential to more clearly define the mechanisms underlying the linear and non-linear processes within the mammalian cochlea.

  11. Differentiation of Basal Cell Carcinoma Subtypes in Multi-Beam Swept Source Optical Coherence Tomography (MSS-OCT).

    Science.gov (United States)

    Meekings, Adam; Utz, Sarah; Ulrich, Martina; Bienenfeld, Amanda; Nandanan, Naveen; Fisher, Juliya; McKenzie, Gordon; Siegel, Daniel M; Feldman, Eleanor; Markowitz, Orit

    2016-05-01

    Optical coherence tomography (OCT) is a technique that enables real-time in-vivo examination of tissue. This technology provides the clinician with the potential to use a non-invasive tool in the identification and diagnosis of many skin lesions. However, the diagnostic features of basal cell carcinoma have not yet been described with comparison to their histopathology. To identify and describe key features of basal cell carcinoma (BCC) and its subtypes as they present in multi-beam Swept Source - OCT (MSS-OCT), and to correlate those against conventional histopathology. A total of 40 lesions were assessed by MSS-OCT prior to biopsy. 60-slice OCT images of the lesions were obtained and correlated with histology sections taken in the same plane. OCT scans were assessed retrospectively by a panel to determine the OCT criteria for BCC and its subtypes. The following diagnostic criteria were identified: hyporeflective ovoid structures (40/40), dark halo boundaries (38/40), epidermal thinning (28/40), and collagen compression (14/40). Lesional tissue also showed a destruction of layers when compared to the surrounding normal tissue. In addition to the shared criteria, other subtypes showed distinct diagnostic criteria. With its higher sensitivity, using MSS-OCT allowed for non-invasive, accurate identification of the key diagnostic features of BCC and its subtypes with high correlation to the histopathologic features found with biopsy. J Drugs Dermatol. 2016;15(5):545-550.

  12. Microscope-Integrated Intraoperative Ultrahigh-Speed Swept-Source Optical Coherence Tomography for Widefield Retinal and Anterior Segment Imaging.

    Science.gov (United States)

    Lu, Chen D; Waheed, Nadia K; Witkin, Andre; Baumal, Caroline R; Liu, Jonathan J; Potsaid, Benjamin; Joseph, Anthony; Jayaraman, Vijaysekhar; Cable, Alex; Chan, Kinpui; Duker, Jay S; Fujimoto, James G

    2018-02-01

    To demonstrate the feasibility of retinal and anterior segment intraoperative widefield imaging using an ultrahigh-speed, swept-source optical coherence tomography (SS-OCT) surgical microscope attachment. A prototype post-objective SS-OCT using a 1,050-nm wavelength, 400 kHz A-scan rate, vertical cavity surface-emitting laser (VCSEL) light source was integrated to a commercial ophthalmic surgical microscope after the objective. Each widefield OCT data set was acquired in 3 seconds (1,000 × 1,000 A-scans, 12 × 12 mm 2 for retina and 10 × 10 mm 2 for anterior segment). Intraoperative SS-OCT was performed in 20 eyes of 20 patients. In six of seven membrane peels and five of seven rhegmatogenous retinal detachment repair surgeries, widefield retinal imaging enabled evaluation pre- and postoperatively. In all seven cataract cases, anterior imaging evaluated the integrity of the posterior lens capsule. Ultrahigh-speed SS-OCT enables widefield intraoperative viewing in the posterior and anterior eye. Widefield imaging visualizes ocular structures and pathology without requiring OCT realignment. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:94-102.]. Copyright 2018, SLACK Incorporated.

  13. Noninvasive cross-sectional imaging of proximal caries using swept-source optical coherence tomography (SS-OCT) in vivo.

    Science.gov (United States)

    Shimada, Yasushi; Nakagawa, Hisaichi; Sadr, Alireza; Wada, Ikumi; Nakajima, Masatoshi; Nikaido, Toru; Otsuki, Masayuki; Tagami, Junji; Sumi, Yasunori

    2014-07-01

    The aim of this study was to determine the diagnostic accuracy of swept-source optical coherent tomography (SS-OCT) in detecting and estimating the depth of proximal caries in posterior teeth in vivo. SS-OCT images and bitewing radiographs were obtained from 86 proximal surfaces of 53 patients. Six examiners scored the locations according to a caries lesion depth scale (0-4) using SS-OCT and the radiographs. The results were compared with clinical observations obtained after the treatment. SS-OCT could detect the presence of proximal caries in tomograms that were synthesized based on the backscatter signal obtained from the proximal carious lesion through occlusal enamel. SS-OCT showed significantly higher sensitivity and larger area under the receiver operating characteristic curve than radiographs for the detection of cavitated enamel lesions and dentin caries (Student's t -test, p proximal lesions in the clinical environment. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Accuracy of a New Swept-Source Optical Coherence Tomography Biometer for IOL Power Calculation and Comparison to IOLMaster.

    Science.gov (United States)

    Savini, Giacomo; Hoffer, Kenneth J; Shammas, H John; Aramberri, Jaime; Huang, Jinhai; Barboni, Piero

    2017-10-01

    To investigate the accuracy of the measurements provided by a new optical biometer (OA-2000, Tomey Corporation, Nagoya, Japan) for calculating the intraocular lens (IOL) power and to compare the refractive outcomes to those obtained with the IOLMaster 500 (Carl Zeiss Meditec, Jena, Germany). In this interventional multicenter study, consecutive patients having cataract surgery were enrolled. Only the IOL model used in the largest sample of patients was selected and the eyes implanted with that IOL were subsequently analyzed. The OA-2000, an optical biometer based on swept-source optical coherence tomography (SS-OCT), was used to measure axial length and corneal power in all eyes. IOL power was calculated with the Hoffer Q, Holladay 1, and SRK/T formulas. In a subsample of eyes, the IOL power was also calculated with measurements obtained by partial coherence interferometry (IOLMaster 500). The median absolute error and percentage of eyes with a prediction error of ±0.50 diopters (D) or less were calculated. Two hundred forty-nine eyes were analyzed. Using SS-OCT, the median absolute error ranged between 0.33 (Holladay 1) and 0.35 (SRK/T) D. The rate of eyes with a prediction error of ±0.50 D or less ranged between 71.5% (Hoffer Q) and 67.1% (SRK/T). In the subsample of 87 eyes with measurements by both devices, the median absolute error was lower with the OA-2000 (Hoffer Q: P = .0377; Holladay 1: P = .0191; SRK/T: P = .0087). The SS-OCT-based optical biometer investigated in the current study provides accurate measurements for IOL power calculation and seems to offer more predictable refractive results compared to the partial coherence interferometry IOLMaster. [J Refract Surg. 2017;33(10):690-695.]. Copyright 2017, SLACK Incorporated.

  15. An intelligent despeckling method for swept source optical coherence tomography images of skin

    Science.gov (United States)

    Adabi, Saba; Mohebbikarkhoran, Hamed; Mehregan, Darius; Conforto, Silvia; Nasiriavanaki, Mohammadreza

    2017-03-01

    Optical Coherence Optical coherence tomography is a powerful high-resolution imaging method with a broad biomedical application. Nonetheless, OCT images suffer from a multiplicative artefacts so-called speckle, a result of coherent imaging of system. Digital filters become ubiquitous means for speckle reduction. Addressing the fact that there still a room for despeckling in OCT, we proposed an intelligent speckle reduction framework based on OCT tissue morphological, textural and optical features that through a trained network selects the winner filter in which adaptively suppress the speckle noise while preserve structural information of OCT signal. These parameters are calculated for different steps of the procedure to be used in designed Artificial Neural Network decider that select the best denoising technique for each segment of the image. Results of training shows the dominant filter is BM3D from the last category.

  16. Polarization sensitive optical coherence tomography at 1060 nm for retinal imaging

    International Nuclear Information System (INIS)

    Torzicky, T.

    2014-01-01

    The aim of this thesis was to develop a Polarization Sensitive Optical Coherence Tomography (PS-OCT) device for ocular imaging in the 1 µm wavelength range and to explore its capabilities to image healthy subjects and patients with various retinal disorders. PS-OCT set-ups working in the 840 nm range have been used in several clinical studies, for examining different retinal pathologies. Especially the segmentation of the retinal pigment epithelium (RPE) based on PS-OCT data shows advantages in cases of age related macular degeneration (AMD) in comparison to segmentation based on intensity images from commercial OCT systems. OCT imaging in the 1 µm wavelength region has recently gained popularity for ophthalmic applications due to the fact that it is perfectly suitable for enhanced visualization of choroid and sclera. This is due to decreased scattering and absorption in the RPE with increasing wavelength and due to the local absorption minimum of water (the vitreous of the eye consists mainly of water) for wavelengths around 1060 nm. An additional advantage is that a higher imaging quality in patients with corneal haze or cataract can be achieved when using OCT systems working at 1 µm. In this work we combine the advantages of PS-OCT imaging with the enhanced penetration depth of the 1 µm wavelength range for acquiring intensity, retardation, axis orientation and degree of polarization uniformity (DOPU) images of choroid and sclera. As a first step different PS-OCT set-ups working at 1060 nm were developed and a comparison regarding set-up parameters and imaging performance was accomplished. The two different set-ups that were built and investigated were a spectrometer based Fourier Domain OCT set-up and a swept source Fourier Domain OCT set-up. The swept source set-up was tested with two different light sources, a commercially available swept source laser (A-Scan rate of 100 kHz) and a prototype of a Fourier Domain Mode Locked (FDML) laser (A-Scan rate of 350

  17. Swept-Source Optical Coherence Tomography Angiography Findings in Torpedo Maculopathy.

    Science.gov (United States)

    Ali, Zaria; Shields, Carol Lally; Jasani, Kirti; Aslam, Tariq Mehmood; Balaskas, Konstantinos

    2017-11-01

    Torpedo maculopathy is a rare congenital anomaly of the retinal pigment epithelium (RPE). Various imaging modalities have been used to assess cases of torpedo maculopathy, including optical coherence tomography (OCT) and fundus autofluorescence (FAF). OCT angiography (OCTA) offers combined structural and flow characteristics of imaged lesions. The authors present OCTA findings in two cases of torpedo maculopathy. Common features include loss of RPE and choriocapillaris allowing greater visualization of larger vessels in the outer choroid. This confirms the potential of OCTA to provide greater detail of retinal and choroidal architecture and elucidate the histopathology of retino-choridal lesions. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:932-935.]. Copyright 2017, SLACK Incorporated.

  18. Wide-field human photoreceptor morphological analysis using phase-resolved sensorless adaptive optics swept-source OCT (Conference Presentation)

    Science.gov (United States)

    Ju, Myeong Jin; Heisler, Morgan; Zawadzki, Robert J.; Bonora, Stefano; Jian, Yifan; Sarunic, Marinko V.

    2017-02-01

    Adaptive optics optical coherence tomography (AO-OCT) systems capable of 3D high resolution imaging have been applied to posterior eye imaging in order to resolve the fine morphological features in the retina. Human cone photoreceptors have been extensively imaged and studied for the investigation of retinal degeneration resulting in photoreceptor cell death. However, there are still limitations of conventional approaches to AO in the clinic, such as relatively small field-of-view (FOV) and the complexities in system design and operation. In this research, a recently developed phase-resolved Sensorless AO Swept Source based OCT (SAO-SS-OCT) system which is compact in size and easy to operate is presented. Owing to its lens-based system design, wide-field imaging can be performed up to 6° on the retina. A phase stabilization unit was integrated with the OCT system. With the phase stabilized OCT signal, we constructed retinal micro-vasculature image using a phase variance technique. The retinal vasculature image was used to align and average multiple OCT volumes acquired sequentially. The contrast-enhanced photoreceptor projection image was then extracted from the averaged volume, and analyzed based on its morphological features through a novel photoreceptor structure evaluation algorithm. The retinas of twelve human research subjects (10 normal and 2 pathological cases) were measured in vivo. Quantitative parameters used for evaluating the cone photoreceptor mosaic such as cell density, cell area, and mosaic regularity are presented and discussed. The SAO-SS-OCT system and the proposed photoreceptor evaluation method has significant potential to reveal early stage retinal diseases associated with retinal degeneration.

  19. Nerve Fiber Flux Analysis Using Wide-Field Swept-Source Optical Coherence Tomography.

    Science.gov (United States)

    Tan, Ou; Liu, Liang; Liu, Li; Huang, David

    2018-02-01

    To devise a method to quantify nerve fibers over their arcuate courses over an extended peripapillary area using optical coherence tomography (OCT). Participants were imaged with 8 × 8-mm volumetric OCT scans centered at the optic disc. A new quantity, nerve fiber flux (NFF), represents the cross-sectional area transected perpendicular to the nerve fibers. The peripapillary area was divided into 64 tracks with equal flux. An iterative algorithm traced the trajectory of the tracks assuming that the relative distribution of the NFF was conserved with compensation for fiber connections to ganglion cells on the macular side. Average trajectory was averaged from normal eyes and use to calculate the NFF maps for glaucomatous eyes. The NFF maps were divided into eight sectors that correspond to visual field regions. There were 24 healthy and 10 glaucomatous eyes enrolled. The algorithm converged on similar patterns of NFL tracks for all healthy eyes. In glaucomatous eyes, NFF correlated with visual field sensitivity in the arcuate sectors (Spearman ρ = 0.53-0.62). Focal nerve fiber loss in glaucomatous eyes appeared as uniform tracks of NFF defects that followed the expected arcuate fiber trajectory. Using an algorithm based on the conservation of flux, we derived nerve fiber trajectories in the peripapillary area. The NFF map is useful for the visualization of focal defects and quantification of sector nerve fiber loss from wide-area volumetric OCT scans. NFF provides a cumulative measure of volumetric loss along nerve fiber tracks and could improve the detection of focal glaucoma damage.

  20. Silver nanoparticles (AgNPs) as a contrast agent for imaging of animal tissue using swept-source optical coherence tomography (SSOCT)

    Science.gov (United States)

    Mondal, Indranil; Raj, Shipra; Roy, Poulomi; Poddar, Raju

    2018-01-01

    We present noninvasive three-dimensional depth-resolved imaging of animal tissue with a swept-source optical coherence tomography system at 1064 nm center wavelength and silver nanoparticles (AgNPs) as a potential contrast agent. A swept-source laser light source is used to enable an imaging rate of 100 kHz (100 000 A-scans s-1). Swept-source optical coherence tomography is a new variant of the optical coherence tomography (OCT) technique, offering unique advantages in terms of sensitivity, reduction of motion artifacts, etc. To enhance the contrast of an OCT image, AgNPs are utilized as an exogeneous contrast agent. AgNPs are synthesized using a modified Tollens method and characterization is done by UV-vis spectroscopy, dynamic light scattering, scanning electron microscopy and energy dispersive x-ray spectroscopy. In vitro imaging of chicken breast tissue, with and without the application of AgNPs, is performed. The effect of AgNPs is studied with different exposure times. A mathematical model is also built to calculate changes in the local scattering coefficient of tissue from OCT images. A quantitative estimation of scattering coefficient and contrast is performed for tissues with and without application of AgNPs. Significant improvement in contrast and increase in scattering coefficient with time is observed.

  1. Agreement between Gonioscopic Examination and Swept Source Fourier Domain Anterior Segment Optical Coherence Tomography Imaging

    Directory of Open Access Journals (Sweden)

    Mohammed Rigi

    2016-01-01

    Full Text Available Purpose. To evaluate interobserver, intervisit, and interinstrument agreements for gonioscopy and Fourier domain anterior segment optical coherence tomography (FD ASOCT for classifying open and narrow angle eyes. Methods. Eighty-six eyes with open or narrow anterior chamber angles were included. The superior angle was classified open or narrow by 2 of 5 glaucoma specialists using gonioscopy and imaged by FD ASOCT in the dark. The superior angle of each FD ASOCT image was graded as open or narrow by 2 masked readers. The same procedures were repeated within 6 months. Kappas for interobserver and intervisit agreements for each instrument and interinstrument agreements were calculated. Results. The mean age was 50.9 (±18.4 years. Interobserver agreements were moderate to good for both gonioscopy (0.57 and 0.69 and FD ASOCT (0.58 and 0.75. Intervisit agreements were moderate to excellent for both gonioscopy (0.53 to 0.86 and FD ASOCT (0.57 and 0.85. Interinstrument agreements were fair to good (0.34 to 0.63, with FD ASOCT classifying more angles as narrow than gonioscopy. Conclusions. Both gonioscopy and FD ASOCT examiners were internally consistent with similar interobserver and intervisit agreements for angle classification. Agreement between instruments was fair to good, with FD ASOCT classifying more angles as narrow than gonioscopy.

  2. Validation of swept source optical coherence tomography (SS-OCT) for the diagnosis of smooth surface caries in vitro.

    Science.gov (United States)

    Nakagawa, Hisaichi; Sadr, Alireza; Shimada, Yasushi; Tagami, Junji; Sumi, Yasunori

    2013-01-01

    An accurate evaluation of the extent of dental caries and possible progress of the lesion from enamel into dentin is very important in clinical dentistry. Dentists need an imaging technology that can noninvasively and reliably quantify the extent of caries. This study aimed to evaluate the effectiveness of non-polarized swept source optical coherence tomography (OCT) in evaluating the extent of caries on smooth enamel surfaces. One-hundred and twenty-seven investigation sites on the enamel surfaces of 93 extracted teeth were selected randomly and examined visually. The presence and extent of caries were scored by experienced and inexperienced dentists using each observation method (0: no caries; 1: enamel demineralization without surface breakdown; 2: enamel breakdown due to caries; 3: deep caries involving the dentin). The same locations were then examined using OCT, following which the teeth were sectioned using a diamond saw and viewed directly under a confocal laser scanning microscope (CLSM). Sensitivity and specificity indices for OCT and VI were calculated and compared. The results were analysed statistically using receiver operating characteristic (ROC) curves. Enamel and dentin caries were outlined by a visible boundary on the cross-sectional OCT images. The modality showed superior results for the detection of dentinal caries; higher sensitivity and Az values could be obtained in the ROC curves, especially by experienced dentists. Cross-sectional imaging of the natural caries lesions on smooth enamel surface by OCT enables efficient diagnosis of the lesion type, extent and dentin involvement. SS-OCT can demonstrate the cross-sectional image of smooth surface enamel caries as highlighted zone in tomogram. It is crucial to determine the extent of the lesion, whether it reaches beyond DEJ or not by a non-invasive and safe technique. OCT can give clinicians information about internal tooth structure and will help clinical decision making on surgical

  3. Can Probability Maps of Swept-Source Optical Coherence Tomography Predict Visual Field Changes in Preperimetric Glaucoma?

    Science.gov (United States)

    Lee, Won June; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho

    2017-12-01

    To determine the usefulness of swept-source optical coherence tomography (SS-OCT) probability maps in detecting locations with significant reduction in visual field (VF) sensitivity or predicting future VF changes, in patients with classically defined preperimetric glaucoma (PPG). Of 43 PPG patients, 43 eyes were followed-up on every 6 months for at least 2 years were analyzed in this longitudinal study. The patients underwent wide-field SS-OCT scanning and standard automated perimetry (SAP) at the time of enrollment. With this wide-scan protocol, probability maps originating from the corresponding thickness map and overlapped with SAP VF test points could be generated. We evaluated the vulnerable VF points with SS-OCT probability maps as well as the prevalence of locations with significant VF reduction or subsequent VF changes observed in the corresponding damaged areas of the probability maps. The vulnerable VF points were shown in superior and inferior arcuate patterns near the central fixation. In 19 of 43 PPG eyes (44.2%), significant reduction in baseline VF was detected within the areas of structural change on the SS-OCT probability maps. In 16 of 43 PPG eyes (37.2%), subsequent VF changes within the areas of SS-OCT probability map change were observed over the course of the follow-up. Structural changes on SS-OCT probability maps could detect or predict VF changes using SAP, in a considerable number of PPG eyes. Careful comparison of probability maps with SAP results could be useful in diagnosing and monitoring PPG patients in the clinical setting.

  4. Swept source optical coherence tomography measurement of the iris-trabecular contact (ITC) index: a new parameter for angle closure.

    Science.gov (United States)

    Ho, Sue-Wei; Baskaran, Mani; Zheng, Ce; Tun, Tin A; Perera, Shamira A; Narayanaswamy, Arun K; Friedman, David S; Aung, Tin

    2013-04-01

    To evaluate the inter- and intra-observer agreement of measurement of the iris-trabecular contact (ITC) index, a measure of the degree of angle closure, using swept source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan). One randomly selected eye of 60 subjects was imaged under dark room conditions. The SSOCT 3-dimensional angle scan simultaneously obtains 128 radial scans of the anterior chamber for the entire circumference of the angle. Post-imaging analysis estimated the ITC index using in-built software. For intra-observer agreement for image grading, one examiner performed the grading twice in a masked fashion and random order after a 1-week interval. A second examiner graded images to assess inter-observer agreement for image grading. For intra-observer agreement for image acquisition, a single operator imaged patients twice. For inter-observer agreement for image acquisition, a single observer graded two sets of images acquired by two different operators on the same patient. Bland-Altman plots and 95 % limits of agreement (LOA) were reported. Study subjects were predominantly Chinese (54/60, 90 %) and female (42/60, 70 %), with a mean age of 65.5 years. The median ITC index for eyes with open angles (31/60) and closed angles was 20 % (95 % confidence interval [CI] - 13.6, 27.8) and 49 % (95%CI - 35.5, 69.2) respectively. The mean difference (95 % LOA) for intra-observer agreement for image grading and image acquisition were -0.8 % (-8.2, 6.5) and 0.6 % (-10.9, 9.7); corresponding inter- observer agreement were 0.1 % (-10, 10.1) and -0.3 % (-11.1, 10.5) respectively. The inter- and intra-observer agreement of the ITC index, as a measure of extent of angle closure using SSOCT, was good.

  5. Polarization sensitive optical coherence tomography in equine bone

    Science.gov (United States)

    Jacobs, J. W.; Matcher, S. J.

    2009-02-01

    Optical coherence tomography (OCT) has been used to image equine bone samples. OCT and polarization sensitive OCT (PS-OCT) images of equine bone samples, before and after demineralization, are presented. Using a novel approach, taking a series of images at different angles of illumination, the polar angle and true birefringence of collagen within the tissue is determined, at one site in the sample. The images were taken before and after the bones were passed through a demineralization process. The images show an improvement in depth penetration after demineralization allowing better visualization of the internal structure of the bone and the optical orientation of the collagen. A quantitative measurement of true birefringence has been made of the bone; true birefringence was shown to be 1.9x10-3 before demineralization increasing to 2.7x10-3 after demineralization. However, determined collagen fiber orientation remains the same before and after demineralization. The study of bone is extensive within the field of tissue engineering where an understanding of the internal structures is essential. OCT in bone, and improved depth penetration through demineralization, offers a useful approach to bone analysis.

  6. Polarization sensitive optical frequency domain imaging system for endobronchial imaging.

    Science.gov (United States)

    Li, Jianan; Feroldi, Fabio; de Lange, Joop; Daniels, Johannes M A; Grünberg, Katrien; de Boer, Johannes F

    2015-02-09

    A polarization sensitive endoscopic optical frequency domain imaging (PS-OFDI) system with a motorized distal scanning catheter is demonstrated. It employs a passive polarization delay unit to multiplex two orthogonal probing polarization states in depth, and a polarization diverse detection unit to detect interference signal in two orthogonal polarization channels. Per depth location four electro-magnetic field components are measured that can be represented in a complex 2x2 field matrix. A Jones matrix of the sample is derived and the sample birefringence is extracted by eigenvalue decomposition. The condition of balanced detection and the polarization mode dispersion are quantified. A complex field averaging method based on the alignment of randomly pointing field phasors is developed to reduce speckle noise. The variation of the polarization states incident on the tissue due to the circular scanning and catheter sheath birefringence is investigated. With this system we demonstrated imaging of ex vivo chicken muscle, in vivo pig lung and ex vivo human lung specimens.

  7. Assessment of circumferential angle-closure by the iris-trabecular contact index with swept-source optical coherence tomography.

    Science.gov (United States)

    Baskaran, Mani; Ho, Sue-Wei; Tun, Tin A; How, Alicia C; Perera, Shamira A; Friedman, David S; Aung, Tin

    2013-11-01

    To evaluate the diagnostic performance of the iris-trabecular contact (ITC) index, a measure of the degree of angle-closure, using swept-source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) in comparison with gonioscopy. Prospective observational study. A total of 108 normal subjects and 32 subjects with angle-closure. The SSOCT 3-dimensional angle scans, which obtain radial scans for the entire circumference of the angle, were performed under dark conditions and analyzed using customized software by a single examiner masked to the subjects' clinical details. The ITC index was calculated as a percentage of the angle that was closed on SSOCT images. First-order agreement coefficient (AC1) statistics and area under the receiver operating characteristic curve (AUC) analyses were performed for angle-closure on the basis of the ITC index in comparison with gonioscopy. Angle-closure on gonioscopy was defined as nonvisibility of posterior trabecular meshwork for at least 2 quadrants. Agreement of the ITC index with gonioscopically defined angle-closure was assessed using the AC1 statistic. Study subjects were predominantly Chinese (95.7%) and female (70.7%), with a mean age of 59.2 (standard deviation, 8.9) years. The median ITC index was 15.24% for gonioscopically open-angle eyes (n = 108) and 48.5% for closed-angle eyes (n = 32) (P = 0.0001). The agreement for angle-closure based on ITC index cutoffs (>35% and ≥50%) and gonioscopic angle-closure was 0.699 and 0.718, respectively. The AUC for angle-closure detection using the ITC index was 0.83 (95% confidence interval, 0.76-0.89), with an ITC index >35% having a sensitivity of 71.9% and specificity of 84.3%. The ITC index is a summary measure of the circumferential extent of angle-closure as imaged with SSOCT. The index had moderate agreement and good diagnostic performance for angle-closure with gonioscopy as the reference standard. Copyright © 2013 American Academy of

  8. Polarization-sensitive optical frequency domain imaging based on unpolarized light

    NARCIS (Netherlands)

    Kim, K.H.; Park, B. H.; Tu, Y.P.; Hasan, T.; Lee, B.; Li, J.; de Boer, J.F.

    2011-01-01

    Polarization-sensitive optical coherence tomography (PS-OCT) is an augmented form of OCT, providing 3D images of both tissue structure and polarization properties. We developed a new method of polarization-sensitive optical frequency domain imaging (PS-OFDI), which is based on a wavelength-swept

  9. Clinical Factors Associated with Lamina Cribrosa Thickness in Patients with Glaucoma, as Measured with Swept Source Optical Coherence Tomography.

    Directory of Open Access Journals (Sweden)

    Kazuko Omodaka

    Full Text Available To investigate the influence of various risk factors on thinning of the lamina cribrosa (LC, as measured with swept-source optical coherence tomography (SS-OCT; Topcon.This retrospective study comprised 150 eyes of 150 patients: 22 normal subjects, 28 preperimetric glaucoma (PPG patients, and 100 open-angle glaucoma patients. Average LC thickness was determined in a 3 x 3 mm cube scan of the optic disc, over which a 4 x 4 grid of 16 points was superimposed (interpoint distance: 175 μm, centered on the circular Bruch's membrane opening. The borders of the LC were defined as the visible limits of the LC pores. The correlation of LC thickness with Humphrey field analyzer-measured mean deviation (MD; SITA standard 24-2, circumpapillary retinal nerve fiber layer thickness (cpRNFLT, the vertical cup-to-disc (C/D ratio, and tissue mean blur rate (MBR was determined with Spearman's rank correlation coefficient. The relationship of LC thickness with age, axial length, intraocular pressure (IOP, MD, the vertical C/D ratio, central corneal thickness (CCT, and tissue MBR was determined with multiple regression analysis. Average LC thickness and the correlation between LC thickness and MD were compared in patients with the glaucomatous enlargement (GE optic disc type and those with non-GE disc types, as classified with Nicolela's method.We found that average LC thickness in the 16 grid points was significantly associated with overall LC thickness (r = 0.77, P < 0.001. The measurement time for this area was 12.4 ± 2.4 minutes. Average LC thickness in this area had a correlation coefficient of 0.57 with cpRNFLT (P < 0.001 and 0.46 (P < 0.001 with MD. Average LC thickness differed significantly between the groups (normal: 268 ± 23 μm, PPG: 248 ± 13 μm, OAG: 233 ± 20 μm. Multiple regression analysis showed that MD (β = 0.29, P = 0.013, vertical C/D ratio (β = -0.25, P = 0.020 and tissue MBR (β = 0.20, P = 0.034 were independent variables significantly

  10. In vivo three-dimensional imaging of normal tissue and tumors in the rabbit pleural cavity using endoscopic swept source optical coherence tomography with thoracoscopic guidance

    OpenAIRE

    Xie, Tuqiang; Liu, Gangjun; Kreuter, Kelly; Mahon, Sari; Colt, Henri; Mukai, David; Peavy, George M.; Chen, Zhongping; Brenner, Matthew

    2009-01-01

    The purpose of this study was to develop a dynamic tunable focal distance graded-refractive-index lens rod-based high-speed 3-D swept-source (SS) optical coherence tomography (OCT) endoscopic system and demonstrate real-time in vivo, high-resolution (10-μm) imaging of pleural-based malignancies in an animal model. The GRIN lens-based 3-D SS OCT system, which images at 39 fps with 512 A-lines per frame, was able to capture images of and detect abnormalities during thoracoscopy in the thoracic ...

  11. Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry.

    Science.gov (United States)

    Gao, Rongrong; Chen, Hao; Savini, Giacomo; Miao, Yaxin; Wang, Xiaorui; Yang, Jing; Zhao, Weiqi; Wang, Qinmei; Huang, Jinhai

    2017-05-30

    The purpose of the current study was to compare the measurements between a new optical biometer based on swept-source optical coherence tomography (SS-OCT), the OA-2000 (Tomey, Japan), and an optical biometer based on optical low coherence reflectometry (OLCR), the Lenstar (Haag-Streit, Switzerland). Ninety-nine eyes of 99 healthy subjects were included. The axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), keratometry (K) readings, including flat K (Kf), steep K (Ks), mean K (Km), astigmatism vectors J 0 , J 45 at diameters of 2.5 and 3.0 mm, and white-to-white diameter (WTW) were measured three times each using both biometer in normal eyes by random sequence. Bland-Altman analysis showed good agreement between the SS-OCT and OLCR devices for AL, AD, ACD, LT, with narrow 95% LoA (-0.05 to 0.07 mm, -0.09 to 0.10 mm, -0.10 to 0.09 mm, and -0.06 to 0.22 mm, respectively), and the P values of ACD were both >0.05. The CCT, Kf, Ks, Km, J 0 , J 45 and WTW values provided by the OA-2000 were in good agreement with the Lenstar, and statistically significant differences were detected for some of them but not clinical differences. The agreement was excellent especially for AL.

  12. TiO2 nanoparticles as exogenous contrast agent for 1 µm swept source optical coherence tomography: an in vitro study

    Science.gov (United States)

    Kumar, Atul; Mondal, Indranil; Roy, Poulomi; Poddar, Raju

    2018-03-01

    Optical coherence tomography (OCT) is a rapidly evolving, robust technology that has profoundly changed the practice of medical imaging. Swept source OCT (SSOCT) combines the standard time domain and the spatially encoded frequency domain OCT. We have employed a high-speed SSOCT system that utilizes a swept source laser with an A-scan rate of 100 kHz and a central wavelength of 1060 nm for the imaging of the tissue. SSOCT at 1060 nm allows for high penetration in the tissue. TiO2 nanoparticles (NPs) are mostly used for various experimental purposes as an exogenous imaging contrast agent. The in vitro imaging of chicken breast tissue is performed with and without the application of TiO2 NPs for exogenous contrast. Characterization of the chemically synthesized TiO2 NPs was done with dynamic light scattering and a scanning electron microscope method. The effect of TiO2 is studied at different exposure times. A significant improvement in the contrast to noise ratio has been observed through the in vitro imaging of a TiO2 treated tissue.

  13. Variability of choroidal and retinal thicknesses in healthy eyes using swept-source optical coherence tomography – implications for designing clinical trials

    Directory of Open Access Journals (Sweden)

    Caramoy A

    2017-10-01

    Full Text Available Albert Caramoy,1 Ludwig M Heindl2 1Eye Center Wolfsburg-Fallersleben, Wolfsburg, 2Department of Ophthalmology, University of Cologne, Cologne, Germany Aim: The aim was to study the variability of choroidal scleral interface (CSI thickness in healthy subjects and its relevance for designing future studies. Methods: A total of 123 volunteers were imaged using swept-source optical coherence tomography. Early treatment diabetic retinopathy grid was used. Results: Mean central retinal thickness was 285.85±14.53 µm and 287.18±12.93 µm, and mean central CSI thickness was 273.94±77.77 µm and 271.19±78.85 µm for the right and left eyes, respectively. Mean retinal and CSI thicknesses correlated negatively with age (p=0.023, r=–0.208 and p<0.0001, r=–0.426, respectively and axial length (p=0.016, r=–0.220 and p<0.0001, r=–0.504, respectively. To detect a CSI change of at least 112 µm, a sample size of 11 or 36 per group is needed for a single- or double-arm study, respectively (α=0.05, power =0.90, no loss to follow-up, assuming standard deviation in future studies as 100 µm. Conclusion: Future clinical studies using CSI as end point are possible with regard to sample size needed. Keywords: swept-source optical coherence tomography, choroidal thickness, retinal thickness, clinical trials

  14. Tuning of successively scanned two monolithic Vernier-tuned lasers and selective data sampling in optical comb swept source optical coherence tomography

    Science.gov (United States)

    Choi, Dong-hak; Yoshimura, Reiko; Ohbayashi, Kohji

    2013-01-01

    Monolithic Vernier tuned super-structure grating distributed Bragg reflector (SSG-DBR) lasers are expected to become one of the most promising sources for swept source optical coherence tomography (SS-OCT) with a long coherence length, reduced sensitivity roll-off, and potential capability for a very fast A-scan rate. However, previous implementations of the lasers suffer from four main problems: 1) frequencies deviate from the targeted values when scanned, 2) large amounts of noise appear associated with abrupt changes in injection currents, 3) optically aliased noise appears due to a long coherence length, and 4) the narrow wavelength coverage of a single chip limits resolution. We have developed a method of dynamical frequency tuning, a method of selective data sampling to eliminate current switching noise, an interferometer to reduce aliased noise, and an excess-noise-free connection of two serially scanned lasers to enhance resolution to solve these problems. An optical frequency comb SS-OCT system was achieved with a sensitivity of 124 dB and a dynamic range of 55-72 dB that depended on the depth at an A-scan rate of 3.1 kHz with a resolution of 15 μm by discretely scanning two SSG-DBR lasers, i.e., L-band (1.560-1.599 μm) and UL-band (1.598-1.640 μm). A few OCT images with excellent image penetration depth were obtained. PMID:24409394

  15. Polarization sensitive optical coherence tomography - a review [Invited

    NARCIS (Netherlands)

    de Boer, Johannes F.; Hitzenberger, Christoph K.; Yasuno, Yoshiaki

    2017-01-01

    Optical coherence tomography (OCT) is now a well-established modality for high-resolution cross-sectional and three-dimensional imaging of transparent and translucent samples and tissues. Conventional, intensity based OCT, however, does not provide a tissue-specific contrast, causing an ambiguity

  16. Robot-assisted three-dimensional registration for cochlear implant surgery using a common-path swept-source optical coherence tomography probe

    Science.gov (United States)

    Gurbani, Saumya S.; Wilkening, Paul; Zhao, Mingtao; Gonenc, Berk; Cheon, Gyeong Woo; Iordachita, Iulian I.; Chien, Wade; Taylor, Russell H.; Niparko, John K.; Kang, Jin U.

    2014-05-01

    Cochlear implantation offers the potential to restore sensitive hearing in patients with severe to profound deafness. However, surgical placement of the electrode array within the cochlea can produce trauma to sensorineural components, particularly if the initial turn of the cochlea is not successfully navigated as the array is advanced. In this work, we present a robot-mounted common-path swept-source optical coherence tomography endoscopic platform for three-dimensional (3-D) optical coherence tomography (OCT) registration and preoperative surgical planning for cochlear implant surgery. The platform is composed of a common-path 600-μm diameter fiber optic rotary probe attached to a five degrees of freedom robot capable of 1 μm precision movement. The system is tested on a dry fixed ex vivo human temporal bone, and we demonstrate the feasibility of a 3-D OCT registration of the cochlea to accurately describe the spatial and angular profiles of the canal formed by the scala tympani into the first cochlear turn.

  17. Robot-assisted three-dimensional registration for cochlear implant surgery using a common-path swept-source optical coherence tomography probe.

    Science.gov (United States)

    Gurbani, Saumya S; Wilkening, Paul; Zhao, Mingtao; Gonenc, Berk; Cheon, Gyeong Woo; Iordachita, Iulian I; Chien, Wade; Taylor, Russell H; Niparko, John K; Kang, Jin U

    2014-05-01

    Cochlear implantation offers the potential to restore sensitive hearing in patients with severe to profound deafness. However, surgical placement of the electrode array within the cochlea can produce trauma to sensorineural components, particularly if the initial turn of the cochlea is not successfully navigated as the array is advanced. In this work, we present a robot-mounted common-path swept-source optical coherence tomography endoscopic platform for three-dimensional (3-D) optical coherence tomography (OCT) registration and preoperative surgical planning for cochlear implant surgery. The platform is composed of a common-path 600-μm diameter fiber optic rotary probe attached to a five degrees of freedom robot capable of 1 μm precision movement. The system is tested on a dry fixed ex vivo human temporal bone, and we demonstrate the feasibility of a 3-D OCT registration of the cochlea to accurately describe the spatial and angular profiles of the canal formed by the scala tympani into the first cochlear turn.

  18. ASYMMETRY IN MACULAR CHOROIDAL THICKNESS PROFILE BETWEEN BOTH EYES IN A HEALTHY POPULATION MEASURED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY.

    Science.gov (United States)

    Ruiz-Medrano, Jorge; Flores-Moreno, Ignacio; Peña-García, Pablo; Montero, Javier A; Duker, Jay S; Ruiz-Moreno, José M

    2015-10-01

    To determine the difference in macular choroidal thickness (CT) profile between eyes in healthy individuals using swept-source optical coherence tomography. Cross-sectional noninterventional study. One hundred and forty eyes from 70 healthy patients with spherical equivalent between ± 3 D and with difference ≤ 0.25 D between eyes were scanned using a swept-source optical coherence tomography (Topcon Corporation). Cross-sectional noninterventional study. One hundred and forty eyes from 70 healthy patients with spherical equivalent between ± 3 D and with difference #0.25 D between eyes were scanned using a swept-source optical coherence tomography (Topcon Corporation). A horizontal CT profile of the macula was created in both eyes by manually measuring the subfoveal CT from the posterior edge of retinal pigment epithelium (RPE) to the choroid/sclera junction. Three determinations were performed at successive points 1,000 mm nasal to the fovea and 5 more temporal to the fovea. The differences in CT between both eyes were analyzed. Mean age was 25.4 ± 19.9 years (from 4 to 75). The mean spherical equivalent was 0.18 ± 1.37 D (from -3 to +3). Mean macular nasal CT was thicker in the right eye (RE) than in the left eye (LE) (228.11 ± 69.23 μm vs. 212.27 ± 62.71 μm; P = 0.0002; Student's t-test paired data). Mean subfoveal CT and mean temporal CT was not statistically significantly different between the eyes. No statistically significant differences were observed comparing spherical equivalent in the RE compared with the LE. Both men and women showed a thicker mean nasal choroid in the RE versus the left (men, 226.97 ± 61.56 μm vs. 209.87 ± 60.31 μm; women, 229.63 ± 79.39 μm vs. 215.47 ± 66.68 μm, P = 0.003 and P = 0.03, respectively; Student's t-test paired data). At each nasal determination, CT in the RE was statistically significantly thicker than the LE (N1: 283.72 ± 81.10 μm vs. 269.76 ± 75.81 μm [P = 0.001]; in N2: 230.45 ± 73.47 μm vs. 211

  19. Segmented swept source optical coherence tomography angiography assessment of the perifoveal vasculature in patients with X-linked juvenile retinoschisis: a serial case report

    Directory of Open Access Journals (Sweden)

    Stringa F

    2017-10-01

    Full Text Available Francesco Stringa,1,2 Emmanouli Tsamis,1,3 Alessandro Papayannis,1 Katarzyna Chwiejczak,1 Assad Jalil,2 Susmito Biswas,1,2,4 Hassan Ahmad,1 Paulo Eduardo Stanga1,2,4 1Manchester Vision Regeneration (MVR at NIHR/Wellcome Trust Manchester Clinical Research Facility, 2Manchester Royal Eye Hospital, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre, 3Division of Pharmacy and Optometry, School of Health Sciences, 4Division of Evolution and Genomic Sciences, School of Biological Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester Academic Health Science Centre, Manchester, UK Purpose: To describe perifoveal microvascular changes occurring in X-linked juvenile retinoschisis (XLRS using swept source optical coherence tomography angiography (SS OCTA.Patients and methods: This is a serial case report of three patients. Retrospective data of patients affected by XLRS were collected. Structural optical coherence tomography (OCT and color fundus photography (CFPh were carried out with Topcon® OCT 2000 3D OCT as part of the standard care. Two patients were imaged on Topcon Atlantis® SS OCTA and one on Topcon Triton® SS OCTA. SS OCTA images were acquired using the 3 × 3 mm fovea-centered cubes scanning protocol. Analysis of both perifoveal superficial vascular plexus (pSVP and perifoveal deep vascular plexus (pDVP was performed by two observers after automated segmentation.Results: Four eyes of three males (mean age 14 ± 3.8 years were analyzed. All eyes showed foveoschisis on CFPh images. OCT B-scans of three eyes showed schistic cysts in the ganglion cell layer, inner nuclear layer (INL and outer nuclear layer (ONL; in one eye, cysts were depicted in INL and ONL only. In two eyes, SS OCTA showed abnormal foveal avascular zone (FAZ shape in the pSVP, and in the other two, FAZ shape was abnormal in both plexuses. In all eyes, retinal vascular abnormalities (ie

  20. In vivo imaging of human burn injuries with polarization-sensitive optical coherence tomography

    NARCIS (Netherlands)

    Kim, K.H.; Pierce, M. C.; Maguluri, G. N.; Park, B. H.; Yoon, S.J.; Lydan, M.; Sheridan, R.; de Boer, J.F.

    2012-01-01

    The accurate determination of burn depth is critical in the clinical management of burn wounds. Polarization- sensitive optical coherence tomography (PS-OCT) has been proposed as a potentially non-invasive method for determining burn depth by measuring thermally induced changes in the structure and

  1. Three-Dimensional Morphometric Analysis of the Iris by Swept-Source Anterior Segment Optical Coherence Tomography in a Caucasian Population.

    Science.gov (United States)

    Invernizzi, Alessandro; Giardini, Piero; Cigada, Mario; Viola, Francesco; Staurenghi, Giovanni

    2015-07-01

    We analyzed by swept-source anterior segment optical coherence tomography (SS-ASOCT) the three-dimensional iris morphology in a Caucasian population, and correlated the findings with iris color, iris sectors, subject age, and sex. One eye each from consecutive healthy emmetropic (refractive spherical equivalent ± 3 diopters) volunteers were selected for the study. The enrolled eye underwent standardized anterior segment photography to assess iris color. Iris images were assessed by SS-ASOCT for volume, thickness, width, and pupil size. Sectoral variations of morphometric data among the superior, nasal, inferior, and temporal sectors were recorded. A total of 135 eyes from 57 males and 78 females, age 49 ± 17 years, fulfilled the inclusion criteria. All iris morphometric parameters varied significantly among the different sectors (all P Iris total volume and thickness were significantly correlated with increasingly darker pigmentation (P iris color. Age did not affect iris volume or thickness; iris width increased and pupil diameter decreased with age (rs = 0.52, rs = -0.58, respectively). There was no effect of sex on iris volume, thickness, or pupil diameter; iris width was significantly greater in males (P = 0.007). Morphology of the iris varied by iris sector, and iris color was associated with differences in iris volume and thickness. Morphological parameter variations associated with iris color, sector, age, and sex can be used to identify pathological changes in suspect eyes. To be effective in clinical settings, construction of iris morphological databases for different ethnic and racial populations is essential.

  2. A pilot study to image the vascular network of small melanocytic choroidal tumors with speckle noise-free 1050-nm swept source optical coherence tomography (OCT choroidal angiography).

    Science.gov (United States)

    Maloca, Peter; Gyger, Cyrill; Hasler, Pascal W

    2016-06-01

    To visualize and measure the vascular network of melanocytic choroidal tumors with speckle noise-free swept source optical coherence tomography (SS-OCT choroidal angiography). Melanocytic choroidal tumors from 24 eyes were imaged with 1050-nm optical coherence tomography (Topcon DRI OCT-1 Atlantis). A semi-automated algorithm was developed to remove speckle noise and to extract and measure the volume of the choroidal vessels from the obtained OCT data. In all cases, analysis of the choroidal vessels could be performed with SS-OCT without the need for pupillary dilation. The proposed method allows speckle noise-free, structure-guided visualization and measurement of the larger choroidal vessels in three dimensions. The obtained data suggest that speckle noise-free OCT may be more effective at identifying choroidal structures than traditional OCT methods. The measured volume of the extracted choroidal vessels of Haller's layer and Sattler's layer in the examined tumorous eyes was on average 0.982463955 mm(3) /982463956 μm(3) (range of 0.209764406 mm(3) /209764405.9 μm(3)to 1.78105544 mm(3) /1781055440 μm(3)). Full thickness obstruction of the choroidal vasculature by the tumor was found in 18 cases (72 %). In seven cases (18 %), choroidal vessel architecture did not show pronounced morphological abnormalities (18 %). Speckle noise-free OCT may serve as a new illustrative imaging technology and enhance visualization of the choroidal vessels without the need for dye injection. OCT can be used to identify and evaluate the choroidal vessels of melanocytic choroidal tumors, and may represent a potentially useful tool for imaging and monitoring of choroidal nevi and melanoma.

  3. Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes.

    Science.gov (United States)

    Ghoreishi, Seyed Mohammad; Mortazavi, Seyed Ali Akbar; Abtahi, Zahra-Alsadat; Abtahi, Mohammad-Ali; Sonbolestan, Seyed Ali; Abtahi, Seyed-Hossein; Mohammadinia, Mohadeseh; Isfahani, Kimia Nekouie

    2017-08-01

    The purpose of the study was to assess the agreement of anterior segment optical coherence tomography with its older well-known opponent i.e., Sheimpflug imaging in evaluation of the cornea in normal and keratoconus subjects. 107 normal and 56 keratoconus eyes were evaluated with the anterior segment optical coherence tomography followed by the Scheimpflug imaging. Parameters included axial keratometry data in both of steep and flat meridians, mean keratometry and the astigmatism values in the central 4.0 mm zone, central, thinnest and apex corneal thicknesses, Q-value in 8 mm zone and pupil diameter. Corneal topographic maps were recorded and were evaluated for anterior highest and lowest points, posterior highest and lowest points. Average values were recorded for analysis. All anterior cornea keratometry indices showed perfect agreement between two devices in normal corneas; while the level of agreement in keratoconus cases ranged from moderate to strong. All posterior keratometry indices also showed perfect agreement in both groups; except for flat K in normal corneas and steep K in KC ones. The amount of corneal cylinder in normal corneas had perfect agreement, and moderate to strong agreement in anterior/posterior cornea in keratoconus group. Anterior highest and lowest points showed strong and perfect agreement in normal and keratoconus cases, respectively. Posterior highest and lowest points showed strong agreement in normal cases. Thickness indices (central, thinnest, and apex thicknesses) showed perfect agreement between two devices in both normal and KC groups. Mean values of anterior and posterior highest points were statistically higher in Scheimpflug system. Although two imaging technologies had statistically numerical different output, it seems that they have a good agreement in most parameters.

  4. Comparison of microleakage of Scotchbond™ Universal Adhesive with methacrylate resin in Class V restorations by two methods: Swept source optical coherence tomography and dye penetration.

    Science.gov (United States)

    Kermanshah, Hamid; Khorsandian, Hossein

    2017-01-01

    One of the most important factors in restoration failure is microleakage at the restoration interface. Furthermore, a new generation of bonding, Scotchbond Universal (multi-mode adhesive), has been introduced to facilitate the bonding steps. The aim of this study was to compare the microleakage of Class V cavities restored using Scotchbond™ Universal with Scotchbond Multi-Purpose in two procedures. Eighteen freshly extracted human molars were used in this study. Thirty-six standardized Class V cavities were prepared on the buccal and lingual surfaces. The teeth were divided into three groups: (1) Group A: Scotchbond Universal with "self-etching" procedure and nanohybrid composite Filtek Z350. (2) Group B: Scotchbond Universal with "total etching" procedure and Filtek Z350. (3) Group C: Scotchbond Multi-Purpose and Filtek Z350. Microleakage at enamel and dentinal margins was evaluated after thermocycling under 5000 cycles by two methods of microleakage assay: swept source optical coherence tomography (OCT) and dye penetration. Wilcoxon's signed-rank test and Kruskal-Wallis test were used to analyze microleakage. In silver nitrate dye penetration method, group A exhibited the minimum microleakage at dentin margins and group C exhibited the minimum microleakage at enamel margins ( P < 0.05). Furthermore, in OCT method, group C demonstrated the minimum microleakage at enamel margins ( P = 0.047), with no difference in the microleakage rate at dentin margins. Scotchbond Universal with "self-etching" procedure at dentin margin exhibited more acceptable performance compared to the Scotchbond Multi-Purpose with the two methods.

  5. Combined in-depth, 3D, en face imaging of the optic disc, optic disc pits and optic disc pit maculopathy using swept-source megahertz OCT at 1050 nm.

    Science.gov (United States)

    Maertz, Josef; Kolb, Jan Philip; Klein, Thomas; Mohler, Kathrin J; Eibl, Matthias; Wieser, Wolfgang; Huber, Robert; Priglinger, Siegfried; Wolf, Armin

    2018-02-01

    To demonstrate papillary imaging of eyes with optic disc pits (ODP) or optic disc pit associated maculopathy (ODP-M) with ultrahigh-speed swept-source optical coherence tomography (SS-OCT) at 1.68 million A-scans/s. To generate 3D-renderings of the papillary area with 3D volume-reconstructions of the ODP and highly resolved en face images from a single densely-sampled megahertz-OCT (MHz-OCT) dataset for investigation of ODP-characteristics. A 1.68 MHz-prototype SS-MHz-OCT system at 1050 nm based on a Fourier-domain mode-locked laser was employed to acquire high-definition, 3D datasets with a dense sampling of 1600 × 1600 A-scans over a 45° field of view. Six eyes with ODPs, and two further eyes with glaucomatous alteration or without ocular pathology are presented. 3D-rendering of the deep papillary structures, virtual 3D-reconstructions of the ODPs and depth resolved isotropic en face images were generated using semiautomatic segmentation. 3D-rendering and en face imaging of the optic disc, ODPs and ODP associated pathologies showed a broad spectrum regarding ODP characteristics. Between individuals the shape of the ODP and the appending pathologies varied considerably. MHz-OCT en face imaging generates distinct top-view images of ODPs and ODP-M. MHz-OCT generates high resolution images of retinal pathologies associated with ODP-M and allows visualizing ODPs with depths of up to 2.7 mm. Different patterns of ODPs can be visualized in patients for the first time using 3D-reconstructions and co-registered high-definition en face images extracted from a single densely sampled 1050 nm megahertz-OCT (MHz-OCT) dataset. As the immediate vicinity to the SAS and the site of intrapapillary proliferation is located at the bottom of the ODP it is crucial to image the complete structure and the whole depth of ODPs. Especially in very deep pits, where non-swept-source OCT fails to reach the bottom, conventional swept-source devices and the MHz-OCT alike are feasible

  6. Imaging of human breast tissue using polarization sensitive optical coherence tomography

    Science.gov (United States)

    Verma, Y.; Gautam, M.; Divakar Rao, K.; Swami, M. K.; Gupta, P. K.

    2011-12-01

    We report a study on the use of polarization sensitive optical coherence tomography (PSOCT) for discriminating malignant (invasive ductal carcinoma), benign (fibroadenoma) and normal (adipocytes) breast tissue sites. The results show that while conventional OCT, that utilizes only the intensity of light back-scattered from tissue microstructures, is able to discriminate breast tissues as normal (adipocytes) and abnormal (malignant and benign) tissues, PS-OCT helps in discriminating between malignant and benign tissue sites also. The estimated values of birefringence obtained from the PSOCT imaging show that benign breast tissue samples have significantly higher birefringence as compared to the malignant tissue samples.

  7. Non-invasive assessment of corneal crosslinking changes using polarization sensitive optical coherence tomography

    Science.gov (United States)

    Alonso-Caneiro, D.; Yamanari, M.; Fukuda, S.; Hoshi, S.; Nagase, S.; Oshika, T.; Yasuno, Y.; Collins, M.

    2013-03-01

    Collagen crosslinking (CXL) has shown promising results in the prevention of the progression of keratoconus and corneal ectasia. However, techniques for in vivo and in situ assessment of the treatment are limited. In this study, ex vivo porcine eyes were treated with a chemical CXL agent (glutaraldehyde), during which polarization sensitive optical coherence tomography (PS-OCT) recordings were acquired simultaneously to assess the sensitivity of the technique to assess changes in the cornea. The results obtained in this study suggest that PSOCT may be a suitable technique to measure CXL changes in situ and to assess the local changes in the treated region of the cornea.

  8. FDML swept source at 1060 nm using a tapered amplifier

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2010-01-01

    We present a novel frequency-swept light source working at 1060nm that utilizes a tapered amplifier as gain medium. These devices feature significantly higher saturation power than conventional semiconductor optical amplifiers and can thus improve the limited output power of swept sources...... in this wavelength range. We demonstrate that a tapered amplifier can be integrated into a fiber-based swept source and allows for high-speed FDML operation. The developed light source operates at a sweep rate of 116kHz with an effective average output power in excess of 30mW. With a total sweep range of 70 nm...

  9. Fiber-Based Polarization Diversity Detection for Polarization-Sensitive Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Hamid Pahlevaninezhad

    2014-09-01

    Full Text Available We present a new fiber-based polarization diversity detection (PDD scheme for polarization sensitive optical coherence tomography (PSOCT. This implementation uses a new custom miniaturized polarization-maintaining fiber coupler with single mode (SM fiber inputs and polarization maintaining (PM fiber outputs. The SM fiber inputs obviate matching the optical lengths of the two orthogonal OCT polarization channels prior to interference while the PM fiber outputs ensure defined orthogonal axes after interference. Advantages of this detection scheme over those with bulk optics PDD include lower cost, easier miniaturization, and more relaxed alignment and handling issues. We incorporate this PDD scheme into a galvanometer-scanned OCT system to demonstrate system calibration and PSOCT imaging of an achromatic quarter-wave plate, fingernail in vivo, and chicken breast, salmon, cow leg, and basa fish muscle samples ex vivo.

  10. Retinal pigment epithelium findings in patients with albinism using wide-field polarization-sensitive optical coherence tomography.

    Science.gov (United States)

    Schütze, Christopher; Ritter, Markus; Blum, Robert; Zotter, Stefan; Baumann, Bernhard; Pircher, Michael; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2014-11-01

    To investigate pigmentation characteristics of the retinal pigment epithelium (RPE) in patients with albinism using wide-field polarization-sensitive optical coherence tomography compared with intensity-based spectral domain optical coherence tomography and fundus autofluorescence imaging. Five patients (10 eyes) with previously genetically diagnosed albinism and 5 healthy control subjects (10 eyes) were imaged by a wide-field polarization-sensitive optical coherence tomography system (scan angle: 40 × 40° on the retina), sensitive to melanin contained in the RPE, based on the polarization state of backscattered light. Conventional intensity-based spectral domain optical coherence tomography and fundus autofluorescence examinations were performed. Retinal pigment epithelium-pigmentation was analyzed qualitatively and quantitatively based on depolarization assessed by polarization-sensitive optical coherence tomography. This study revealed strong evidence of polarization-sensitive optical coherence tomography to specifically image melanin in the RPE. Depolarization of light backscattered by the RPE in patients with albinism was reduced compared with normal subjects. Heterogeneous RPE-specific depolarization characteristics were observed in patients with albinism. Reduction of depolarization observed in the light backscattered by the RPE in patients with albinism corresponds to expected decrease of RPE pigmentation. The degree of depigmentation of the RPE is possibly associated with visual acuity. Findings suggest that different albinism genotypes result in heterogeneous levels of RPE pigmentation. Polarization-sensitive optical coherence tomography showed a heterogeneous appearance of RPE pigmentation in patients with albinism depending on different genotypes.

  11. Asymmetric MQW semiconductor optical amplifier with low-polarization sensitivity of over 90-nm bandwidth

    Science.gov (United States)

    Nkanta, Julie E.; Maldonado-Basilio, Ramón; Abdul-Majid, Sawsan; Zhang, Jessica; Hall, Trevor J.

    2013-12-01

    An exhausted capacity of current Passive Optical Networks has been anticipated as bandwidth-hungry applications such as HDTV and 3D video become available to end-users. To enhance their performance, the next generation optical access networks have been proposed, using optical carriers allocated within the E-band (1360-1460 nm). It is partly motivated by the low-water peak fiber being manufactured by Corning. At these wavelengths, choices for low cost optical amplifiers, with compact size, low energy consumption and feasibility for integration with other optoelectronic components are limited, making the semiconductor optical amplifiers (SOA) a realistic solution. An experimental characterization of a broadband and low polarization sensitive asymmetric multi quantum well (MQW) SOA operating in the E-band is reported. The SOA device is composed of nine 6 nm In1-xGaxAsyP1-y 0.2% tensile strained asymmetric MQW layers sandwiched between nine latticed matched 6 nm InGaAsP barrier layers. The active region is grown on an n-doped InP substrate and buried by p-doped InGaAsP layers. The SOA devices have 7-degrees tilt anti-reflected coated facets, with 2 μm ridge width, and a cavity length of 900 μm. For input powers of -10 dBm and -20 dBm, a maximum gain of 20 dB at 1360 nm with a polarization insensitivity under 3 dB for over 90 nm bandwidth is measured. Polarization sensitivity of less than 0.5 dB is observed for some wavelengths. Obtained results indicate a promising SOA with broadband amplification, polarization insensitivity and high gain. These SOAs were designed and characterized at the Photonics Technology Laboratory, University of Ottawa, Canada.

  12. Characterization of muscle stretching and damage using polarization-sensitive optical coherence tomography (PS-OCT)

    Science.gov (United States)

    Chen, Dongsheng; Zeng, Nan; Liu, Celong; Ma, Hui

    2012-12-01

    In this paper, we study muscle elastic drawing and damage using our lab's polarization-sensitive optical coherence tomography (PS-OCT) instrument and polarization sensitive Monte Carlo program. First, we acquire two-dimensional PS-OCT images of elastically drawn and injured muscle, injury processes including dehydration and hydrolysis, we extract some characteristics from experimental results including extinction coefficient, integral reflectivity and birefringence and so on, which will change during muscle is being elastically drawn or injured. In order to further understand and evaluate the degree of muscle elastic drawing or damage according to the measurements parameters mentioned above, we do some corresponding simulations using our lab's Monte Carlo program, which is based on a sphere cylinder birefringence model and can simulate complicated tissue containing anisotropic microstructures and various polarization imaging and measurement systems. For muscle elastic drawing, we find that integral reflectivity sometimes increases and decreases as muscle's elastic drawing continues, and through simulation we are unable to find the relationship between extinction coefficients and muscle elastic drawing. As for muscle damage, we simulate two processes: dehydration and hydrolysis. We find that as dehydration deepens, the birefringence of muscle is increasing but getting slowly and the integral reflectivity is decreasing, and as hydrolysis deepens, the birefringence decreases and the integral reflectivity decreases almost linearly. Through the analysis above, we demonstrate the validity of those parameters to characterize muscle elasticity and fiber structure and explain its potential for assessment of muscle damage.

  13. Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo

    Science.gov (United States)

    Choi, Woo June; Wang, Ruikang K.

    2015-10-01

    We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an extended usable imaging depth range of more than 2 mm in turbid biological tissue. Using this approach, we show deep brain imaging in mice with an open-skull cranial window preparation, revealing intact mouse brain anatomy from the superficial cerebral cortex to the deep hippocampus. VCSEL SS-OCT would be applicable to small animal studies for the investigation of deep tissue compartments in living brains where diseases such as dementia and tumor can take their toll.

  14. Polarization-sensitive optical coherence tomography for imaging of biological tissues

    Science.gov (United States)

    Chen, Xiaodong; Wang, Yi; Li, Wanhui; Yu, Daoyin

    2006-09-01

    Polarization sensitive optical coherence tomography (PS-OCT) is a new non-contact and non-invasive method for measuring the change of birefringence in biological tissues caused by pathological changes of body. It has great potential in imaging the structural properties of turbid biological media because the polarization state of light backscattered from biological tissues is influenced by the birefringence of fibrous structures. The arrangement is based on a Michelson interferometer with use of quarter-wave plates and polarimeter. Through the detection of light backscattered from biological tissues and reflected from a reference mirror, the optical phase delay between orthogonal polarization compositions propagating in the birefringence media can be measured. PS-OCT is a powerful tool for research of tendon, dentin, lesions, which have strong polarization effective. We in this paper describe the experimental scheme and its mathematical representation, along with the theory of PS-OCT imaging. Besides, we introduce a fiber-based PS-OCT system for measuring the tissue birefringence.

  15. Correlation between polarization sensitive optical coherence tomography and second harmonic generation microscopy in skin.

    Science.gov (United States)

    Le, Viet-Hoan; Lee, Seunghun; Kim, Bumju; Yoon, Yeoreum; Yoon, Calvin J; Chung, Wan Kyun; Kim, Ki Hean

    2015-07-01

    Both polarization sensitive optical coherence tomography (PS-OCT) and second harmonic generation (SHG) microscopy are 3D optical imaging methods providing information related to collagen in the skin. PS-OCT provides birefringence information which is due to the collagen composition of the skin. SHG microscopy visualizes collagen fibers in the skin based on their SHG property. These two modalities have been applied to the same skin pathologies associated with collagen changes, but their relationship has not been examined. In this study, we tried to find the relationship by imaging the same skin samples with both modalities. Various parts of the normal rat skin and burn damaged skin were imaged ex vivo, and their images were analyzed both qualitatively and quantitatively. PS-OCT images were analyzed to obtain tissue birefringence. SHG images were analyzed to obtain collagen orientation indices by applying 2D Fourier transform. The skin samples having higher birefringence values had higher collagen orientation indices, and a linear correlation was found between them. Burn damaged skin showed decreases in both parameters compared to the control skins. This relationship between the bulk and microscopic properties of skin may be useful for further skin studies.

  16. Polarization-Sensitive Optical Coherence Tomography Imaging of Benign and Malignant Laryngeal Lesions: An In Vivo Study

    NARCIS (Netherlands)

    Burns, J.A.; Kim, K.H.; de Boer, J.F.; Anderson, R.R.; Zeitels, S. M.

    2011-01-01

    Objective. Optical coherence tomography (OCT), an imaging technology that provides cross-sectional subsurface tissue structure images using back-scattered light, is a promising noninvasive imaging modality for in vivo assessment of vocal fold layered microstructure. Polarization-sensitive OCT

  17. Polarization-sensitive optical coherence tomography for the nondestructive assessment of the remineralization of dentin

    Science.gov (United States)

    Manesh, Saman K.; Darling, Cynthia L.; Fried, Daniel

    2009-07-01

    Previous studies have demonstrated that polarization-sensitive optical coherence tomography (PS-OCT) can be used to image caries lesions in dentin, measure nondestructively the severity of dentin demineralization, and determine the efficacy of intervention with anticaries agents including fluoride and lasers. The objective of this study is to determine if PS-OCT can be used to nondestructively measure a reduction in the reflectivity of dentin lesions after exposure to a remineralization solution. Although studies have shown the ability of PS-OCT to image the remineralization of lesions in enamel, none have included dentin. PS-OCT images of dentin surfaces are acquired after exposure to an artificial demineralizing solution for six days and a remineralizing solution for 20 days. The integrated reflectivity, depth of demineralization, and thickness of the layer of remineralization are calculated for each of the two treatment groups on each sample. Polarized light microscopy and microradiography are used to measure lesion severity on histological thin sections for comparison. PS-OCT successfully measured the formation of a layer of increased mineral content near the lesion surface. Polorized light microscopy (PLM) and transverse microradiography (TMR) corroborated those results. PS-OCT can be used for the nondestructive measurement of the remineralization of dentin.

  18. In vivo imaging of human burn injuries with polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Kim, Ki Hean; Pierce, Mark C.; Maguluri, Gopi; Park, B. Hyle; Yoon, Sang June; Lydon, Martha; Sheridan, Robert; de Boer, Johannes F.

    2012-06-01

    The accurate determination of burn depth is critical in the clinical management of burn wounds. Polarization-sensitive optical coherence tomography (PS-OCT) has been proposed as a potentially non-invasive method for determining burn depth by measuring thermally induced changes in the structure and birefringence of skin, and has been investigated in pre-clinical burn studies with animal models and ex vivo human skin. In this study, we applied PS-OCT to the in-vivo imaging of two pediatric burn patients. Deep and superficial burned skins along with contralateral controls were imaged in 3D. The imaging size was 8 mm×6 mm×2 mm in width, length, and depth in the air respectively, and the imaging time was approximately 6 s per volume. Superficially burned skins exhibited the same layered structure as the contralateral controls, but more visible vasculature and reduced birefringence compared to the contralateral controls. In contrast, a deeply burned skin showed loss of the layered structure, almost absent vasculature, and smaller birefringence compared to superficial burns. This study suggested the vasculature and birefringence as parameters for characterizing burn wounds.

  19. The hand-hold polarization-sensitive spectral domain optical coherence and its applications

    Science.gov (United States)

    Liu, Hao; Gao, Wanrong

    2017-08-01

    The polarization-sensitive spectral domain optical coherence tomography (PSOCT) has the advantages of being able to measure the polarization properties of samples, such as phase-retardation, diattenuation, depolarization, and optical axis orientation, providing a contrast to identify the diseased area and normal area in tissues in PSOCT images. Conventionally, the sample arm of PSOCT is fixed on the stage where biomedical tissues or models is placed, and the OCT images is acquired by scanning with a galvanometer-based mirror. To be applied in the practical diagnosis, a promising way is to design a hand-held device. To this end, it is required that probe is assembled with a small volume to allow for comprehensively imaging large tissues areas at a microscopic scale, and is available to move on different samples to be acquired quickly with negligible motion artifacts. Meanwhile, the probe should be manufactured wih well stability to avoid system jitter error while it is used to detect the biological tissues in vivo. In this work, a design of a hand-hold fiber-based PSOCT is described. The device is of the size of 10 cm (length) × 8 cm (width) × 6 cm (height). Both the axial resolution and the imaging depth of the system are measured and were approximately 7 μm and 2.5 mm in air, respectively, which are in good agreement with the theoretical predictions. The A-scan rate of the system is 70 kHz. The structure is compact and all the components are fixed on the shell to reduce the motion artifact, resulting in a great stability on measuring the tissues in vivo. The cross sectional images of ex vivo chicken breast, ex vivo pork cartilage and in vivo forearm skin of human wolunteer are presented to demonstrate the capability of the system.

  20. Nano-particle doped hydroxyapatite material evaluation using spectroscopic polarization sensitive optical coherence tomography

    Science.gov (United States)

    Strąkowska, Paulina; Trojanowski, Michał; Gardas, Mateusz; Głowacki, Maciej J.; Kraszewski, Maciej; Strąkowski, Marcin R.

    2015-03-01

    Bio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp. In order to achieve this, we propose to use Optical Coherence Tomography (OCT) for non-destructive and non-invasive evaluation. Our system works in the IR spectrum range, which is helpful due to the wide range of nanocomposites being opaque in the VIS range. In order to use our method we need to measure two samples, one which is a reference HAp solution and second: a similar HAp solution with nanoparticles introduced inside. We use silver nanoparticles below 300 nm. The aim of this research is to analyze the concentration and dispersion of nanodopants in the bio-ceramic matrix. Furthermore, the quality of the HAp coating and deposition process repetition have been monitored. For this purpose the polarization sensitive OCT with additional spectroscopic analysis is being investigated. Despite the other methods, which are suitable for nanocomposite materials evaluation, the OCT with additional features seems to be one of the few which belong to the NDE/NDT group. Here we are presenting the OCT system for evaluation of the HAp with nano-particles, as well as HAp manufacturing process. A brief discussion on the usefulness of OCT for bio-ceramics materials examination is also being presented.

  1. Real-Time Swept Source Optical Coherence Tomography Imaging of the Human Airway Using a Microelectromechanical System Endoscope and Digital Signal Processor

    Science.gov (United States)

    2008-07-01

    1429–1433. [PubMed: 17115049] 4. Adler DC, Chen Y, Huber R, Schmitt J, Connolly J, Fujimoto JG. Three-dimensional endomicroscopy using optical coherence...rate ultrahigh-speed wavelength- swept semiconductor laser. Opt. Lett 2005;30:3159–3161. [PubMed: 16350273] 7. Huber R, Wojtkowski M, Fujimoto JG...19516464] 8. Huber R, Adler DC, Fujimoto JG. Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence

  2. Swept source optical coherence tomography for in vivo growth monitoring of capsicum annuum seeds treated with different NaCl concentrations

    Science.gov (United States)

    Ravichandran, Naresh Kumar; Wijesinghe, Ruchire Eranga; Lee, Seung-Yeol; Shirazi, Muhammad Faizan; Park, Kibeom; Jung, Hee-Young; Jeon, Mansik; Kim, Jeehyun

    2017-04-01

    In this study, Optical coherence tomography (OCT) is demonstrated as a plausible optical tool for in vivo detection of plant seeds and its morphological changes during growth. The experiment was carried out on Capsicum annuum seeds that were treated with different molar concentrations of NaCl to investigate the most optimal concentration for the seed growth. The monitoring process was carried out for 9 consecutive days. The in vivo 2D OCT images of the treated seeds were obtained and compared with seeds that were grown with sterile distilled water. The obtained results confirm the feasibility of using OCT for the proposed application. Normalized A-scan analysis method is utilized for supporting the concluded results.

  3. Quantifying the optical properties and chromophore concentrations of turbid media using polarization sensitive hyperspectral imaging: optical phantom studies

    Science.gov (United States)

    Vasefi, Fartash; Saager, Rolf; Durkin, Anthony J.; MacKinnon, Nicholas; Gussakovsky, Eugene; Chave, Robert; Farkas, Daniel L.

    2013-02-01

    We present a polarization-sensitive hyperspectral imaging system (SkinSpect) that employs a spectrally-programmable light source in the visible and NIR domains. Multiple tissue-mimicking phantoms were fabricated to mimic the optical properties of normal skin as well as pigmented light and dark moles. The phantoms consist of titanium dioxide and a mixture of coffee, red food dye, and naphthol green as the scattering and the three absorptive agents in a polydimethylsiloxane (PDMS) base. Phantoms were produced with both smooth and rough textured surfaces and tested using Spatial Frequency Domain Imaging (SFDI) and Spatially Modulated Quantitative Spectroscopy (SMoQS) for homogeneity as well as determining absorption and scattering variance, respectively. The reflectance spectral images were also recorded using the SkinSpect research prototype; the spectral signatures of the phantoms were calculated using a two-flux single-layer Kubelka-Munk model and non-negative least square fitting routine was applied to extract the relative concentrations of the individual phantom components.

  4. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies

    Directory of Open Access Journals (Sweden)

    Anna K. Nowinska

    2015-01-01

    Full Text Available Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT in eyes with corneal dystrophies (CDs. Methods. Fifty healthy volunteers (50 eyes and 54 patients (96 eyes diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT, anterior chamber depth (ACD, and nasal and temporal trabecular iris angle (nTIA, tTIA were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  5. Measurement of Collagen and Smooth Muscle Cell Content in Atherosclerotic Plaques Using Polarization-Sensitive Optical Coherence Tomography

    Science.gov (United States)

    Nadkarni, Seemantini K.; Pierce, Mark C.; Park, B. Hyle; de Boer, Johannes F.; Whittaker, Peter; Bouma, Brett E.; Bressner, Jason E.; Halpern, Elkan; Houser, Stuart L.; Tearney, Guillermo J.

    2009-01-01

    Objectives The purpose of this study was to investigate the measurement of collagen and smooth muscle cell (SMC) content in atherosclerotic plaques using polarization-sensitive optical coherence tomography (PSOCT). Background A method capable of evaluating plaque collagen content and SMC density can provide a measure of the mechanical fidelity of the fibrous cap and can enable the identification of high-risk lesions. Optical coherence tomography has been demonstrated to provide cross-sectional images of tissue microstructure with a resolution of 10 µm. A recently developed technique, PSOCT measures birefringence, a material property that is elevated in tissues such as collagen and SMCs. Methods We acquired PSOCT images of 87 aortic plaques obtained from 20 human cadavers. Spatially averaged PSOCT birefringence, Φ, was measured and compared with plaque collagen and SMC content, quantified morphometrically by picrosirius red and smooth muscle actin staining at the corresponding locations. Results There was a high positive correlation between PSOCT measurements of Φ and total collagen content in all plaques (r = 0.67, p < 0.001) and in fibrous caps of necrotic core fibroatheromas (r = 0.68, p < 0.001). Polarization-sensitive optical coherence tomography measurements of Φ demonstrated a strong positive correlation with thick collagen fiber content (r = 0.76, p < 0.001) and SMC density (r = 0.74, p < 0.01). Conclusions Our results demonstrate that PSOCT enables the measurement of birefringence in plaques and in fibrous caps of necrotic core fibroatheromas. Given its potential to evaluate collagen content, collagen fiber thickness, and SMC density, we anticipate that PSOCT will significantly improve our ability to evaluate plaque stability in patients. PMID:17397678

  6. Spectro-refractometry of individual microscopic objects using swept-source quantitative phase imaging.

    Science.gov (United States)

    Jung, Jae-Hwang; Jang, Jaeduck; Park, Yongkeun

    2013-11-05

    We present a novel spectroscopic quantitative phase imaging technique with a wavelength swept-source, referred to as swept-source diffraction phase microscopy (ssDPM), for quantifying the optical dispersion of microscopic individual samples. Employing the swept-source and the principle of common-path interferometry, ssDPM measures the multispectral full-field quantitative phase imaging and spectroscopic microrefractometry of transparent microscopic samples in the visible spectrum with a wavelength range of 450-750 nm and a spectral resolution of less than 8 nm. With unprecedented precision and sensitivity, we demonstrate the quantitative spectroscopic microrefractometry of individual polystyrene beads, 30% bovine serum albumin solution, and healthy human red blood cells.

  7. High-power FDML laser for swept source-OCT at 1060 nm

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2010-01-01

    We present a novel frequency-swept light source working at 1060nm that utilizes a tapered amplifier as gain medium. These devices feature significantly higher saturation power than conventional semiconductor optical amplifiers and can thus improve the limited output power of swept sources...... in this wavelength range. We demonstrate that a tapered amplifier can be integrated into a fiber-based swept source and allows for high-speed FDML operation. The developed light source operates at a sweep rate of 116kHz with an effective average output power in excess of 30mW. With a total sweep range of 70 nm...

  8. Segmentation and quantification of retinal lesions in age-related macular degeneration using polarization-sensitive optical coherence tomography.

    Science.gov (United States)

    Baumann, Bernhard; Gotzinger, Erich; Pircher, Michael; Sattmann, Harald; Schuutze, Christopher; Schlanitz, Ferdinand; Ahlers, Christian; Schmidt-Erfurth, Ursula; Hitzenberger, Christoph K

    2010-01-01

    We present polarization-sensitive optical coherence tomography (PS-OCT) for quantitative assessment of retinal pathologies in age-related macular degeneration (AMD). On the basis of the polarization scrambling characteristics of the retinal pigment epithelium, novel segmentation algorithms were developed that allow one to segment pathologic features such as drusen and atrophic zones in dry AMD as well as to determine their dimensions. Results from measurements in the eyes of AMD patients prove the ability of PS-OCT for quantitative imaging based on the retinal features polarizing properties. Repeatability measurements were performed in retinas diagnosed with drusen and geographic atrophy in order to evaluate the performance of the described methods. PS-OCT appears as a promising imaging modality for three-dimensional retinal imaging and ranging with additional contrast based on the structures' tissue-inherent polarization properties.

  9. Fourier domain mode-locked swept source at 1050 nm based on a tapered amplifier

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2010-01-01

    While swept source optical coherence tomography (OCT) in the 1050 nm range is promising for retinal imaging, there are certain challenges. Conventional semiconductor gain media have limited output power, and the performance of high-speed Fourier domain mode-locked (FDML) lasers suffers from...

  10. Polarization sensitive subcutaneous and muscular imaging based on common path optical coherence tomography using near infrared source.

    Science.gov (United States)

    Han, Jae-Ho; Kang, Jin U; Song, Chul Gyu

    2011-08-01

    In this paper, we describe a polarization sensitive (PS) subcutaneous and muscular imaging system based on common path optical coherence tomography (CP-OCT) using a near infrared source. The axial and lateral resolutions of the PS-OCT system are 9 and 6 μm, respectively. The main goal of this work is to build a high-resolution and minimally invasive optical imager for examining various kinds of cutaneous substructures with intrinsic or form birefringence. The internal structural information is extracted by the real-time signal analysis (Fourier Transform) of the modulated spectral intensity depending on the beam and tissue birefringence. The preliminary results using fresh beef longissimus muscle and in vivo Rattus norvegicus (rat) show that it is possible to visualize the birefringence effect of the tissue collagen fibers in the samples in order to achieve superior image contrast and sensitivity for the detection of hidden dermal structures. Compared to conventional CP-OCT, the proposed PS-OCT system provides depth-resolved images, which reflect the tissue birefringence.

  11. Retinal polarization-sensitive optical coherence tomography at 1060 nm with 350 kHz A-scan rate using an Fourier domain mode locked laser

    DEFF Research Database (Denmark)

    Torzicky, Teresa; Marschall, Sebastian; Pircher, Michael

    2013-01-01

    We present a novel, high-speed, polarization-sensitive, optical coherence tomography set-up for retinal imaging operating at a central wavelength of 1060 nm which was tested for in vivo imaging in healthy human volunteers. We use the system in combination with a Fourier domain mode locked laser...

  12. Investigation of acid-etched CO2 laser ablated enamel surfaces using polarization sensitive optical coherence tomography

    Science.gov (United States)

    Nahm, Byung J.; Kang, Hobin; Chan, Kenneth; Fried, Daniel

    2012-01-01

    A carbon dioxide laser operating at the highly absorbed wavelength of 9.3μm with a pulse duration of 10-15μs is ideally suited for caries removal and caries prevention. The enamel thermally modified by the laser has enhanced resistance to acid dissolution. This is an obvious advantage for caries prevention; however, it is often necessary to etch the enamel surface to increase adhesion to composite restorative materials and such surfaces may be more resistant to etching. The purpose of the study was to non-destructively measure the susceptibility of laser-ablated enamel surfaces to acid dissolution before and after acid-etching using Polarization Sensitive Optical Coherence Tomography (PS-OCT). PS-OCT was used to acquire images of bovine enamel surfaces after exposure to laser irradiation at ablative fluence, acid-etching, and a surface softened dissolution model. The integrated reflectivity from lesion and the lesion depth were measured using PS-OCT. Samples were also sectioned for examination by Polarized Light Microscopy (PLM). PS-OCT images showed that acid-etching greatly accelerated the formation of subsurface lesions on both laser-irradiated and non-irradiated surfaces (Plaser modified enamel layer after 5-10 seconds.

  13. Development of an polarization sensitive Fourier domain optical coherence tomography and it utilization on the Mueller matrix determination

    International Nuclear Information System (INIS)

    Raele, Marcus Paulo

    2009-01-01

    This study approached theoretical and experimental aspects related with the development of a polarization sensitive, Fourier domain, optical coherence tomography system (PS-FD-OCT) and its utilization on the Mueller Matrix determination. This work began with a bibliographic revision, which describes since the early studies to the actual state of the art of the technique. The mathematical formalism of Fourier domain low coherence interferometry and light polarization was performed as well. Studies based on numerical simulations, of three different algorithm types, responsible to recover the scattering profile, were done. The implemented algorithms were: Direct Fourier Transform, Interpolation and zero-filling. By the end of the simulation study, was possible to conclude that the algorithm zero-filling 2N presented better characteristics when compared with the others. In the experimental part, firstly different OCT setups were assembled and measurements were done in order to verify aspects related with the theory. Then, using a polymeric sample, birefringence images were performed, which allowed determining the sample birefringence quantitatively. Finally, images taken of different polarization states were collected, and through then images related with the Mueller Matrix elements were calculated, which were analyzed individually. (author)

  14. Assessment of vascularization and myelination following peripheral nerve repair using angiographic and polarization sensitive optical coherence tomography (Conference Presentation)

    Science.gov (United States)

    Nam, Ahhyun S.; Chico-Calero, Isabel; Easow, Jeena M.; Villiger, Martin; Welt, Jonathan; Winograd, Jonathan M.; Randolph, Mark A.; Redmond, Robert W.; Vakoc, Benjamin J.

    2017-02-01

    A severe traumatic injury to a peripheral nerve often requires surgical graft repair. However, functional recovery after these surgical repairs is often unsatisfactory. To improve interventional procedures, it is important to understand the regeneration of the nerve grafts. The rodent sciatic nerve is commonly used to investigate these parameters. However, the ability to longitudinally assess the reinnervation of injured nerves are limited, and to our knowledge, no methods currently exist to investigate the timing of the revascularization in functional recovery. In this work, we describe the development and use of angiographic and polarization-sensitive (PS) optical coherence tomography (OCT) to visualize the vascularization, demyelination and remyelination of peripheral nerve healing after crush and transection injuries, and across a variety of graft repair methods. A microscope was customized to provide 3.6 cm fields of view along the nerve axis with a capability to track the nerve height to maintain the nerve within the focal plane. Motion artifact rejection was implemented in the angiography algorithm to reduce degradation by bulk respiratory motion in the hindlimb site. Vectorial birefringence imaging methods were developed to significantly enhance the accuracy of myelination measurements and to discriminate birefringent contributions from the myelin and epineurium. These results demonstrate that the OCT platform has the potential to reveal new insights in preclinical studies and may ultimately provide a means for clinical intra-surgical assessment of peripheral nerve function.

  15. Analysis of the Origin of Atypical Scanning Laser Polarimetry Patterns by Polarization-Sensitive Optical Coherence Tomography

    Science.gov (United States)

    Götzinger, Erich; Pircher, Michael; Baumann, Bernhard; Hirn, Cornelia; Vass, Clemens; Hitzenberger, Christoph K.

    2010-01-01

    Purpose To analyze the physical origin of atypical scanning laser polarimetry (SLP) patterns. To compare polarization-sensitive optical coherence tomography (PS-OCT) scans to SLP images. To present a method to obtain pseudo-SLP images by PS-OCT that are free of atypical artifacts. Methods Forty-one eyes of healthy subjects, subjects with suspected glaucoma, and patients with glaucoma were imaged by SLP (GDx VCC) and a prototype spectral domain PS-OCT system. The PS-OCT system acquires three-dimensional (3D) datasets of intensity, retardation, and optic axis orientation simultaneously within 3 seconds. B-scans of intensity and retardation and en face maps of retinal nerve fiber layer (RNFL) retardation were derived from the 3D PS-OCT datasets. Results were compared with those obtained by SLP. Results Twenty-two eyes showed atypical retardation patterns, and 19 eyes showed normal patterns. From the 22 atypical eyes, 15 showed atypical patterns in both imaging modalities, five were atypical only in SLP images, and two were atypical only in PS-OCT images. In most (15 of 22) atypical cases, an increased penetration of the probing beam into the birefringent sclera was identified as the source of atypical patterns. In such cases, the artifacts could be eliminated in PS-OCT images by depth segmentation and exclusion of scleral signals. Conclusions PS-OCT provides deeper insight into the contribution of different fundus layers to SLP images. Increased light penetration into the sclera can distort SLP retardation patterns of the RNFL. PMID:19036999

  16. Polarization-Sensitive Optical Coherence Tomographic Documentation of Choroidal Melanin Loss in Chronic Vogt-Koyanagi-Harada Disease.

    Science.gov (United States)

    Miura, Masahiro; Makita, Shuichi; Yasuno, Yoshiaki; Tsukahara, Rintaro; Usui, Yoshihiko; Rao, Narsing A; Ikuno, Yasushi; Uematsu, Sato; Agawa, Tetsuya; Iwasaki, Takuya; Goto, Hiroshi

    2017-09-01

    Vogt-Koyanagi-Harada (VKH) disease is a systemic autoimmune disorder that affects organs with melanocytes. The sunset glow fundus (SGF) in VKH disease was evaluated with polarization-sensitive optical coherence tomography (PS-OCT). The study involved 28 eyes from 14 patients with chronic VKH disease, 21 eyes from 21 age-matched controls, and 22 eyes from 22 high-myopic patients with a tessellated fundus. VKH eyes were grouped into sunset or non-sunset groups on the basis of color fundus images. The presence of melanin in the choroid was determined by using the degree of polarization uniformity (DOPU) obtained by PS-OCT. The sunset glow index (SGI) was calculated by using color fundus images. Presence of an SGF was evaluated by using DOPU, SGI, subfoveal choroidal thicknesses, near-infrared images, and autofluorescence images at 488 nm (SW-AF) and 785 nm (NIR-AF). There were 16 eyes in the sunset group and 12 eyes in the non-sunset group. For all eyes in the sunset group, the disappearance of choroidal melanin was clearly detected with PS-OCT. Percentage areas of low DOPU in the choroidal interstitial stroma of the sunset group were significantly lower than those of other groups and showed no overlap with other groups. The distribution of choroidal thicknesses and SGI in the sunset group substantially overlapped with other groups. The subjective analyses of the sunset and non-sunset groups, using near infrared, SW-AF, or NIR-AF, showed substantial inconsistencies with the PS-OCT results. PS-OCT provides an in vivo objective evaluation of choroidal melanin loss of the SGF in chronic VKH disease.

  17. Lesion size detection in geographic atrophy by polarization-sensitive optical coherence tomography and correlation to conventional imaging techniques.

    Science.gov (United States)

    Schütze, Christopher; Bolz, Matthias; Sayegh, Ramzi; Baumann, Bernhard; Pircher, Michael; Götzinger, Erich; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2013-01-28

    To investigate the reproducibility of automated lesion size detection in patients with geographic atrophy (GA) using polarization-sensitive spectral-domain optical coherence tomography (PS-OCT) and to compare findings with scanning laser ophthalmoscopy (SLO), fundus autofluorescence (FAF), and intensity-based spectral-domain OCT (SD-OCT). Twenty-nine eyes of 22 patients with GA were examined by PS-OCT, selectively identifying the retinal pigment epithelium (RPE). A novel segmentation algorithm was applied, automatically detecting and quantifying areas of RPE atrophy. The reproducibility of the algorithm was assessed, and lesion sizes were correlated with manually delineated SLO, FAF, and intensity-based SD-OCT images to validate the clinical applicability of PS-OCT in GA evaluation. Mean GA lesion size of all patients was 5.28 mm(2) (SD: 4.92) in PS-OCT. Mean variability of individual repeatability measurements was 0.83 mm(2) (minimum: 0.05; maximum: 3.65). Mean coefficient of variation was 0.07 (min: 0.01; max: 0.19). Mean GA area in SLO (Spectralis OCT) was 5.15 mm(2) (SD: 4.72) and 2.5% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area in intensity-based SD-OCT pseudo-SLO images (Cirrus OCT) was 5.14 mm(2) (SD: 4.67) and 2.7% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area of all eyes measured 5.41 mm(2) (SD: 4.75) in FAF, deviating by 2.4% from PS-OCT results (P = 0.89, Pearson correlation coefficient = 0.99, P < 0.01). PS-OCT demonstrated high reproducibility of GA lesion size determination. Results correlated well with SLO, FAF, and intensity-based SD-OCT fundus imaging. PS-OCT may therefore be a valuable and specific imaging modality for automated GA lesion size determination in scientific studies and clinical practice.

  18. Single input state, single–mode fiber–based polarization sensitive optical frequency domain imaging by eigenpolarization referencing

    Science.gov (United States)

    Lippok, Norman; Villiger, Martin; Jun, Chang–Su; Bouma, Brett E.

    2015-01-01

    Fiber–based polarization sensitive OFDI is more challenging than free–space implementations. Using multiple input states, fiber–based systems provide sample birefringence information with the benefit of a flexible sample arm but come at the cost of increased system and acquisition complexity, and either reduce acquisition speed or require increased acquisition bandwidth. Here we show that with the calibration of a single polarization state, fiber–based configurations can approach the conceptual simplicity of traditional free–space configurations. We remotely control the polarization state of the light incident at the sample using the eigenpolarization states of a wave plate as a reference, and determine the Jones matrix of the output fiber. We demonstrate this method for polarization sensitive imaging of biological samples. PMID:25927775

  19. High-speed polarization-sensitive OCT at 1060 nm using a Fourier domain mode-locked swept source

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Torzicky, Teresa; Klein, Thomas

    2012-01-01

    sufficiently large datasets. Here, we demonstrate PS-OCT imaging at 350 kHz A-scan rate using a two-channel PS-OCT system in conjunction with a Fourier domain mode-locked laser. The light source spectrum spans up to 100nm around the water absorption minimum at 1060 nm. By modulating the laser pump current, we...

  20. Strategies to improve phase-stability of ultrafast swept source optical coherence tomography for single shot imaging of transient mechanical waves at 16 kHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Song, Shaozhen; Wei, Wei; Hsieh, Bao-Yu; Pelivanov, Ivan; O' Donnell, Matthew [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Shen, Tueng T.; Wang, Ruikang K., E-mail: wangrk@uw.edu [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Ophthalmology, University of Washington, Seattle, Washington 98104 (United States)

    2016-05-09

    We present single-shot phase-sensitive imaging of propagating mechanical waves within tissue, enabled by an ultrafast optical coherence tomography (OCT) system powered by a 1.628 MHz Fourier domain mode-locked (FDML) swept laser source. We propose a practical strategy for phase-sensitive measurement by comparing the phases between adjacent OCT B-scans, where the B-scan contains a number of A-scans equaling an integer number of FDML buffers. With this approach, we show that micro-strain fields can be mapped with ∼3.0 nm sensitivity at ∼16 000 fps. The system's capabilities are demonstrated on porcine cornea by imaging mechanical wave propagation launched by a pulsed UV laser beam, promising non-contact, real-time, and high-resolution optical coherence elastography.

  1. In vivo polarization-sensitive optical coherence tomography of human burn scars: birefringence quantification and correspondence with histologically determined collagen density

    Science.gov (United States)

    Jaspers, Mariëlle E. H.; Feroldi, Fabio; Vlig, Marcel; de Boer, Johannes F.; van Zuijlen, Paul P. M.

    2017-12-01

    Obtaining adequate information on scar characteristics is important for monitoring their evolution and the effectiveness of clinical treatment. The aberrant type of collagen in scars may give rise to specific birefringent properties, which can be determined using polarization-sensitive optical coherence tomography (PS-OCT). The aim of this pilot study was to evaluate a method to quantify the birefringence of the scanned volume and correlate it with the collagen density as measured from histological slides. Five human burn scars were measured in vivo using a handheld probe and custom-made PS-OCT system. The local retardation caused by the tissue birefringence was extracted using the Jones formalism. To compare the samples, histograms of birefringence values of each volume were produced. After imaging, punch biopsies were harvested from the scar area of interest and sent in for histological evaluation using Herovici polychrome staining. Two-dimensional en face maps showed higher birefringence in scars compared to healthy skin. The Pearson's correlation coefficient for the collagen density as measured by histology versus the measured birefringence was calculated at r=0.80 (p=0.105). In conclusion, the custom-made PS-OCT system was capable of in vivo imaging and quantifying the birefringence of human burn scars, and a nonsignificant correlation between PS-OCT birefringence and histological collagen density was found.

  2. Demonstration of Shot-noise-limited Swept Source OCT Without Balanced Detection.

    Science.gov (United States)

    Fathipour, Vala; Schmoll, Tilman; Bonakdar, Alireza; Wheaton, Skylar; Mohseni, Hooman

    2017-04-26

    Optical coherence tomography (OCT) has been utilized in a rapidly growing number of clinical and scientific applications. In particular, swept source OCT (SS-OCT) has attracted many attentions due to its excellent performance. So far however, the limitations of existing photon detectors have prevented achieving shot-noise-limited sensitivity without using balanced-detection scheme in SS-OCT, even when superconducting single-photon detectors were used. Unfortunately, balanced-detection increases OCT system size and cost, as it requires many additional components to boost the laser power and maintain near ideal balanced performance across the whole optical bandwidth. Here we show for the first time that a photon detector is capable of achieving shot noise limited performance without using the balanced-detection technique in SS-OCT. We built a system using a so-called electron-injection photodetector, with a cutoff-wavelength of 1700 nm. Our system achieves a shot-noise-limited sensitivity of about -105 dB at a reference laser power of ~350 nW, which is more than 30 times lower laser power compared with the best-reported results. The high sensitivity of the electron-injection detector allows utilization of micron-scale tunable laser sources (e.g. VCSEL) and eliminates the need for fiber amplifiers and highly precise couplers, which are an essential part of the conventional SS-OCT systems.

  3. [Imaging Blood Flow and Pulsation of Retinal Vessels with Full-Field Swept-Source OCT].

    Science.gov (United States)

    Spahr, H; Hillmann, D; Hain, C; Pfäffle, C; Sudkamp, H; Franke, G; Koch, P; Hüttmann, G

    2016-12-01

    Optical coherence tomography (OCT) uses interference to image the retina with high axial resolution. In the last 25 years, new technologies have permitted a steady increase in imaging speed, which made it possible to enlarge the imaged field and to avoid motion artefacts. The speed and precision of retinal imaging is now limited by photodamage of the retina caused by the focused OCT beam and by the speed of the scanning mechanics. Full-field swept-source (FF-SS)-OCT decreases irradiance on the retina and dispenses moving parts by using a camera to acquire the full volume of the retina in parallel. Here we show that FF-SS-OCT is rapid and precise enough to image pulsation in the retina induced by the heart beat. Series of OCT volumes 1.8 × 0.7 mm wide and 1.8 mm deep were recorded in young volunteers over a few cycles of the heart beat. Morphology of the retinal vessels, blood flow and tissue motion as caused by vessel pulsation were calculated from the OCT data. FF-SS-OCT was able to visualise the main structures of the neuronal retina, including vessels and small capillaries and without any motion artefacts. Information on three different dynamic processes was obtained from only one recorded series of OCT volumes: pulsation of blood flow and blood pressure in retinal vessels as well as pulsation of the choroid. Delays between arterial and venous pulse and delay between pulsation in retinal and choroidal vessels were calculated. With a time resolution of 0.5 ms, FF-SS-OCT is able to visualise previously unmeasurably fast changes in the retina, including the propagation of pulse waves. Georg Thieme Verlag KG Stuttgart · New York.

  4. Two configurations of miniature Mirau interferometry for swept-source OCT imaging: applications in dermatology and gastroendoscopy

    Science.gov (United States)

    Gorecki, Christophe

    2015-08-01

    The early diagnosis of cancer is essential since it can be treated more effectively when detected earlier. Visual inspection followed by histological examination is, still today, the gold standard for clinicians. However, a large number of unnecessary surgical procedures are still performed. New diagnostics aids are emerging including the recent techniques of optical coherence tomography (OCT) which permits non-invasive 3D optical biopsies of biological tissues, improving patient's quality of life. Nevertheless, the existing bulk or fiber optics systems are expensive, only affordable at the hospital and thus, not sufficiently used by physicians or cancer's specialists as an early diagnosis tool. We developed two different microsystems based on Mirau interferometry and applied for swept source OCT imaging: one for dermatology and second for gastroenterology. In both cases the architecture is based tem based on spectrally tuned Mirau interferometry. The first configuration, developed in the frame of the European project VIAMOS, includes an active array of 4x4 Mirau interferometers. The matrix of Mirau reference mirrors is integrated on top of an electrostatic vertical comb-drive actuator. In second configuration, developed in the frame of Labex ACTION, we adapted VIAMOS technology to develop an OCT endomicroscope with a single-channel passive Mirau interferometer.

  5. In vivo detection of exercised-induced ultrastructural changes in genetically-altered murine skeletal muscle using polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Boppart, Stephen

    2006-02-01

    Skeletal muscle fibers are a known source of form birefringence in biological tissue. The birefringence present in skeletal muscle is associated with the ultrastructure of individual sarcomeres, specifically the arrangement of A-bands corresponding to the thick myosin filaments. Certain structural proteins that prevent damage and maintain the structural and functional health of the muscle fiber preserve the organization of the Abands in skeletal muscle. Therefore, the level of birefringence detected can estimate the health of the muscle as well as the damage incurred during exercise. Murine skeletal muscle from both genetically-altered (mdx) and normal (wild-type) specimens were imaged in vivo with a fiber-based PSOCT imaging system to quantitatively determine the level of birefringence present in the tissue before and after exercise. The mdx muscle lacks dystrophin, a structural protein that is mutated in Duchenne muscular dystrophy in humans. Muscle from these mdx mice exhibited a marked decrease in birefringence after exercise, whereas the wild-type muscle was highly birefringent before and after exercise. The quantitative results from this tissue optics study suggest for the first time that there is a distinct relationship between the degree of birefringence detected using PS-OCT and the sarcomeric ultrastructure present within skeletal muscle.

  6. Comparison of choroidal thickness measurements between spectral-domain OCT and swept-source OCT in normal and diseased eyes.

    Science.gov (United States)

    Zafar, Sidra; Siddiqui, Ma Rehman; Shahzad, Rida

    2016-01-01

    Sub-foveal choroidal thickness (SFCT) is affected in many ocular diseases. The aim of this study was to compare SFCT measurements between Topcon 3D 2000 spectral-domain optical coherence tomography (SD-OCT) and Topcon swept-source OCT (SS-OCT), with different laser wavelengths, in normal and diseased populations. This was a prospective, cross-sectional, noninterventional study including 27 normal volunteers and 27 participants with retinal disease. OCT scans were performed sequentially and under standardized conditions using both SD-OCT and SS-OCT. The OCT scans were evaluated by two independent graders. Paired t -tests and intraclass correlation coefficients (ICCs) were used to assess the statistically significant difference between SFCT measurements as measured by the two devices. Mean SFCT measurements for all 54 participants were 264.9±103.1 μm using SD-OCT (range: 47-470 μm) and 278.5±110.5 μm using SS-OCT (range: 56-502 μm), with an inter-device ICC of 0.850. Greater variability was noted in the diseased eyes. Inter-device ICCs were 0.870 (95% CI; 0.760-0.924) and 0.840 (95% CI; 0.654-0.930) for normal and diseased eyes, respectively. However, the difference was not statistically significant ( P =0.132). Both machines reliably measure SFCT. Larger studies are needed to confirm these findings.

  7. Topological insulator infrared pseudo-bolometer with polarization sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Peter Anand

    2017-10-25

    Topological insulators can be utilized in a new type of infrared photodetector that is intrinsically sensitive to the polarization of incident light and static magnetic fields. The detector isolates single topological insulator surfaces and allows light collection and exposure to static magnetic fields. The wavelength range of interest is between 750 nm and about 100 microns. This detector eliminates the need for external polarization selective optics. Polarization sensitive infrared photodetectors are useful for optoelectronics applications, such as light detection in environments with low visibility in the visible wavelength regime.

  8. Comparison of choroidal thickness measurements between spectral-domain OCT and swept-source OCT in normal and diseased eyes

    Directory of Open Access Journals (Sweden)

    Zafar S

    2016-11-01

    Full Text Available Sidra Zafar,1 MA Rehman Siddiqui,2,3 Rida Shahzad1 1Medical College, Aga Khan University Hospital, 2Department of Ophthalmology, Shahzad Eye Hospital, 3South City Hospital, Karachi, Pakistan Purpose: Sub-foveal choroidal thickness (SFCT is affected in many ocular diseases. The aim of this study was to compare SFCT measurements between Topcon 3D 2000 spectral-domain optical coherence tomography (SD-OCT and Topcon swept-source OCT (SS-OCT, with different laser wavelengths, in normal and diseased populations. Materials and methods: This was a prospective, cross-sectional, noninterventional study including 27 normal volunteers and 27 participants with retinal disease. OCT scans were performed sequentially and under standardized conditions using both SD-OCT and SS-OCT. The OCT scans were evaluated by two independent graders. Paired t-tests and intraclass correlation coefficients (ICCs were used to assess the statistically significant difference between SFCT measurements as measured by the two devices. Results: Mean SFCT measurements for all 54 participants were 264.9±103.1 µm using SD-OCT (range: 47–470 µm and 278.5±110.5 µm using SS-OCT (range: 56–502 µm, with an inter-device ICC of 0.850. Greater variability was noted in the diseased eyes. Inter-device ICCs were 0.870 (95% CI; 0.760–0.924 and 0.840 (95% CI; 0.654–0.930 for normal and diseased eyes, respectively. However, the difference was not statistically significant (P=0.132. Conclusion: Both machines reliably measure SFCT. Larger studies are needed to confirm these findings. Keywords: choroidal imaging, diseased, normal, SD-OCT, SS-OCT

  9. Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500.

    Science.gov (United States)

    Akman, Ahmet; Asena, Leyla; Güngör, Sirel Gür

    2016-09-01

    To compare the measurements and failure rates obtained with a new swept source optical coherence tomography (OCT)-based biometry to IOLMaster 500. Eye Clinic, Baskent University Faculty of Medicine, Ankara, Turkey. Observational cross-sectional study and evaluation of a new diagnostic technology. 188 eyes of 101 subjects were included in the study. Measurements of axial length (AL), anterior chamber depth (ACD), corneal power (K1 and K2) and the measurement failure rate with the new Zeiss IOLMaster 700 were compared with those obtained with the IOLMaster 500. The results were evaluated using Bland-Altman analyses. The differences between both methods were assessed using the paired samples t test, and their correlation was evaluated by intraclass correlation coefficient (ICC). The mean age was 68.32±12.71 years and the male/female ratio was 29/72. The agreements between two devices were outstanding regarding AL (ICC=1.0), ACD (ICC=0.920), K1 (ICC=0.992) and K2 (ICC=0.989) values. IOLMaster 700 was able to measure ACD AL, K1 and K2 in all eyes within high-quality SD limits of the manufacturer. IOLMaster 500 was able to measure ACD in 175 eyes, whereas measurements were not possible in the remaining 13 eyes. AL measurements were not possible for 17 eyes with IOLMaster 500. Nine of these eyes had posterior subcapsular cataracts and eight had dense nuclear cataracts. Although the agreement between the two devices was excellent, the IOLMaster 700 was more effective in obtaining biometric measurements in eyes with posterior subcapsular and dense nuclear cataracts. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second.

    Science.gov (United States)

    Potsaid, Benjamin; Baumann, Bernhard; Huang, David; Barry, Scott; Cable, Alex E; Schuman, Joel S; Duker, Jay S; Fujimoto, James G

    2010-09-13

    We demonstrate ultrahigh speed swept source/Fourier domain ophthalmic OCT imaging using a short cavity swept laser at 100,000 - 400,000 axial scan rates. Several design configurations illustrate tradeoffs in imaging speed, sensitivity, axial resolution, and imaging depth. Variable rate A/D optical clocking is used to acquire linear-in-k OCT fringe data at 100 kHz axial scan rate with 5.3 um axial resolution in tissue. Fixed rate sampling at 1 GSPS achieves a 7.5mm imaging range in tissue with 6.0 um axial resolution at 100 kHz axial scan rate. A 200 kHz axial scan rate with 5.3 um axial resolution over 4mm imaging range is achieved by buffering the laser sweep. Dual spot OCT using two parallel interferometers achieves 400 kHz axial scan rate, almost 2X faster than previous 1050 nm ophthalmic results and 20X faster than current commercial instruments. Superior sensitivity roll-off performance is shown. Imaging is demonstrated in the human retina and anterior segment. Wide field 12x12 mm data sets include the macula and optic nerve head. Small area, high density imaging shows individual cone photoreceptors. The 7.5 mm imaging range configuration can show the cornea, iris, and anterior lens in a single image. These improvements in imaging speed and depth range provide important advantages for ophthalmic imaging. The ability to rapidly acquire 3D-OCT data over a wide field of view promises to simplify examination protocols. The ability to image fine structures can provide detailed information on focal pathologies. The large imaging range and improved image penetration at 1050 m wavelengths promises to improve performance for instrumentation which images both the retina and anterior eye. These advantages suggest that swept source OCT at 1050 nm wavelengths will play an important role in future ophthalmic instrumentation.

  11. A vertebrate retina with segregated colour and polarization sensitivity.

    Science.gov (United States)

    Novales Flamarique, Iñigo

    2017-09-13

    Besides colour and intensity, some invertebrates are able to independently detect the polarization of light. Among vertebrates, such separation of visual modalities has only been hypothesized for some species of anchovies whose cone photoreceptors have unusual ultrastructure that varies with retinal location. Here, I tested this hypothesis by performing physiological experiments of colour and polarization discrimination using the northern anchovy, Engraulis mordax Optic nerve recordings showed that the ventro-temporal (VT), but not the ventro-nasal (VN), retina was polarization sensitive, and this coincided with the exclusive presence of polarization-sensitive photoreceptors in the VT retina. Spectral (colour) sensitivity recordings from the VN retina indicated the contribution of two spectral cone mechanisms to the optic nerve response, whereas only one contributed to the VT retina. This was supported by the presence of only one visual pigment in the VT retina and two in the VN retina, suggesting that only the VN retina was associated with colour sensitivity. Behavioural tests further demonstrated that anchovies could discriminate colour and the polarization of light using the ventral retina. Thus, in analogy with the visual system of some invertebrates, the northern anchovy has a retina with segregated retinal pathways for colour and polarization vision. © 2017 The Author(s).

  12. THE ATACAMA COSMOLOGY TELESCOPE: THE POLARIZATION-SENSITIVE ACTPol INSTRUMENT

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, R. J. [Department of Physics, West Chester University of Pennsylvania, West Chester, PA 19383 (United States); Ade, P. A. R. [School of Physics and Astronomy, Cardiff University, The Parade, Cardiff, Wales, CF24 3AA (United Kingdom); Aiola, S. [Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Angilè, F. E.; Devlin, M. J.; Dicker, S. R. [Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104 (United States); Amiri, M. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z4 (Canada); Beall, J. A.; Becker, D. T.; Fowler, J. W.; Fox, A. E.; Gao, J. [NIST Quantum Sensors Group, 325 Broadway Mailcode 817.03, Boulder, CO 80305 (United States); Cho, H-M. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Choi, S. K.; Grace, E. [Joseph Henry Laboratories of Physics, Jadwin Hall, Princeton University, Princeton, NJ 08544 (United States); Corlies, P.; Gallardo, P. A. [Department of Physics, Cornell University, Ithaca, NY 14853 (United States); Coughlin, K. P.; Datta, R. [Department of Physics, University of Michigan Ann Arbor, MI 48109 (United States); Dünner, R. [Instituto de Astrofísica and Centro de Astro-Ingeniería, Facultad de Física, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, 7820436 Macul, Santiago (Chile); and others

    2016-12-01

    The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3° field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev–Zel’dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

  13. The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

    Science.gov (United States)

    Thornton, R. J.; Ade, P. A. R.; Aiola, S.; Angile, F. E.; Amiri, M.; Beall, J. A.; Becker, D. T.; Cho, H.-M.; Choi, S. K.; Corlies, P.; hide

    2016-01-01

    The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3deg field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev-Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

  14. Polarization sensitive beam bending using a spatially variant photonic crystal

    Science.gov (United States)

    Digaum, Jennefir L.; Pazos, Javier; Rumpf, Raymond; Chiles, Jeff; Fathpour, Sasan; Thomas, Jeremy N.; Kuebler, Stephen M.

    2015-02-01

    A spatially-variant photonic crystal (SVPC) that can control the spatial propagation of electromagnetic waves in three dimensions with high polarization sensitivity was fabricated and characterized. The geometric attributes of the SVPC lattice were spatially varied to make use of the directional phenomena of self-collimation to tightly bend an unguided beam coherently through a 90 degree angle. Both the lattice spacing and the fill factor of the SVPC were maintained to be nearly constant throughout the structure. A finite-difference frequency-domain computational method confirms that the SVPC can self-collimate and bend light without significant diffuse scatter caused by the bend. The SVPC was fabricated using multi-photon direct laser writing in the photo-polymer SU-8. Mid-infrared light having a vacuum wavelength of λ0 = 2.94 μm was used to experimentally characterize the SVPCs by scanning the sides of the structure with optical fibers and measuring the intensity of light emanating from each face. Results show that the SVPC is capable of directing power flow of one polarization through a 90-degree turn, confirming the self-collimating and polarization selective light-guiding properties of the structures.

  15. Combined 60° Wide-Field Choroidal Thickness Maps and High-Definition En Face Vasculature Visualization Using Swept-Source Megahertz OCT at 1050 nm

    OpenAIRE

    Mohler, Kathrin J.; Draxinger, Wolfgang; Klein, Thomas; Kolb, Jan Philip; Wieser, Wolfgang; Haritoglou, Christos; Kampik, Anselm; Fujimoto, James G.; Neubauer, Aljoscha S.; Huber, Robert; Wolf, Armin

    2015-01-01

    The field of view that can be acquired in densely sampled 3D datasets is limited to ∼20° for most commercial OCT devices. We demonstrate ∼60° high-definition volumetric choroidal imaging using our ultrahigh-speed prototype swept-source OCT system.

  16. Combined 60° Wide-Field Choroidal Thickness Maps and High-Definition En Face Vasculature Visualization Using Swept-Source Megahertz OCT at 1050 nm.

    Science.gov (United States)

    Mohler, Kathrin J; Draxinger, Wolfgang; Klein, Thomas; Kolb, Jan Philip; Wieser, Wolfgang; Haritoglou, Christos; Kampik, Anselm; Fujimoto, James G; Neubauer, Aljoscha S; Huber, Robert; Wolf, Armin

    2015-10-01

    To demonstrate ultrahigh-speed swept-source optical coherence tomography (SS-OCT) at 1.68 million A-scans/s for choroidal imaging in normal and diseased eyes over a ∼60° field of view. To investigate and correlate wide-field three-dimensional (3D) choroidal thickness (ChT) and vascular patterns using ChT maps and coregistered high-definition en face images extracted from a single densely sampled Megahertz-OCT (MHz-OCT) dataset. High-definition, ∼60° wide-field 3D datasets consisting of 2088 × 1024 A-scans were acquired using a 1.68 MHz prototype SS-OCT system at 1050 nm based on a Fourier-domain mode-locked laser. Nine subjects (nine eyes) with various chorioretinal diseases or without ocular pathology are presented. Coregistered ChT maps, choroidal summation maps, and depth-resolved en face images referenced to either the retinal pigment epithelium or the choroidal-scleral interface were generated using manual segmentation. Wide-field ChT maps showed a large inter- and intraindividual variance in peripheral and central ChT. In only four of the nine eyes, the location with the largest ChT was coincident with the fovea. The anatomy of the large lumen vessels of the outer choroid seems to play a major role in determining the global ChT pattern. Focal ChT changes with large thickness gradients were observed in some eyes. Different ChT and vascular patterns could be visualized over ∼60° in patients for the first time using OCT. Due to focal ChT changes, a high density of thickness measurements may be favorable. High-definition depth-resolved en face images are complementary to cross sections and thickness maps and enhance the interpretation of different ChT patterns.

  17. Development of an polarization sensitive Fourier domain optical coherence tomography and it utilization on the Mueller matrix determination; Desenvolvimento de um sistema de tomografia por coerencia optica no dominio de Fourier sensivel a polarizacao e sua utilizacao na determinacao das matrizes de Mueller

    Energy Technology Data Exchange (ETDEWEB)

    Raele, Marcus Paulo

    2009-07-01

    This study approached theoretical and experimental aspects related with the development of a polarization sensitive, Fourier domain, optical coherence tomography system (PS-FD-OCT) and its utilization on the Mueller Matrix determination. This work began with a bibliographic revision, which describes since the early studies to the actual state of the art of the technique. The mathematical formalism of Fourier domain low coherence interferometry and light polarization was performed as well. Studies based on numerical simulations, of three different algorithm types, responsible to recover the scattering profile, were done. The implemented algorithms were: Direct Fourier Transform, Interpolation and zero-filling. By the end of the simulation study, was possible to conclude that the algorithm zero-filling 2N presented better characteristics when compared with the others. In the experimental part, firstly different OCT setups were assembled and measurements were done in order to verify aspects related with the theory. Then, using a polymeric sample, birefringence images were performed, which allowed determining the sample birefringence quantitatively. Finally, images taken of different polarization states were collected, and through then images related with the Mueller Matrix elements were calculated, which were analyzed individually. (author)

  18. Real-time full-depth visualization of posterior ocular structures: comparison between Full Depth Imaging Spectral Domain OCT and Swept Source OCT

    Science.gov (United States)

    Barteselli, Giulio; Bartsch, Dirk-Uwe; Weinreb, Robert N; Camacho, Natalia; Nezgoda, Joseph T; Marvasti, Amir H; Freeman, William R

    2015-01-01

    Purpose To compare the real-time visualization of vitreoretino-choroidal structures using Full Depth Imaging (FDI) spectral domain optical coherence tomography (SD-OCT) and swept source (SS)-OCT. Methods Foveal scans using both FDI SD-OCT (Heidelberg Spectralis) and SS-OCT (Topcon DRI OCT-1) were obtained in 40 normal eyes, 40 eyes with macular pathologies, and 40 eyes with glaucoma. FDI SD-OCT images were obtained by manually enhancing the vitreoretinal interface first and then the choroid, while averaging each OCT B-scan 100 times. SS-OCT images were obtained by averaging each B-scan 96 times. After masking and randomly mixing the original OCT images, two independent physicians graded visualization of the premacular bursa, interdigitation zone line, and chorio-scleral boundary, as well as sharpness of choroidal structures. Results A real-time full-depth image of vitreoretino-choroidal structures was successfully achieved with FDI SD-OCT in 118 cases (98.3%) and with SS-OCT in 45 cases (37.5%, pOCT imaging was superior to SS-OCT imaging in visualizing the anterior border of the premacular bursa in 109 eyes (90.8%), with average grading of 1.63 ± 0.53 for the FDI SD-OCT and 0.39 ± 0.52 for the SS-OCT (pOCT was similar to FDI SD-OCT in visualizing the chorio-scleral boundary in 108 eyes (90.0%), with average grading of 1.81 ± 0.39 for the SS-OCT and 1.78 ± 0.38 for the FDI-OCT (p=0.566). The visualization of the interdigitation zone line was identical in the two imaging instruments (p=1.000). The sharpness of the choroidal structures was greater with SS-OCT than with FDI-OCT (pOCT provided a good compromise between vitreous and retino-choroidal structures visualization in real time during scanning procedure. In contrast, SS-OCT imaged well fine choroidal details. Appropriate OCT technology and software should be selected according to its application in clinical settings. PMID:26562563

  19. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS...

  20. Development of the dual SMART micro-surgical system using common-path swept source optical coherence tomography.

    Science.gov (United States)

    Park, H C; Yeo, C B; Gehlbach, P L; Song, C

    2015-01-01

    Manual micro-surgical tasks are fundamentally divided into grasping, cutting and injecting maneuvers performed on biological tissues. Efficient dissection of fibrous tissue from the surface of the retina often requires grasping and cutting maneuvers carried out simultaneously. True bimanual surgery requires that the surgeon contend with the innate hand tremor of two hands at once as well as unpredicted patient's movement. In this study, we develop and test a dual SMART micro-surgical system to suppress bimanual hand tremor during micro-surgical dissection.

  1. Polarization Sensitive Measurements of Molecular Reorientation in a Glass Capacitor Cell

    Science.gov (United States)

    Cooper, Nathan; Lawhead, Carlos; Anderson, Josiah; Shiver, Tegan; Prayaga, Chandra; Ujj, Laszlo

    2014-03-01

    It is well known that molecules having a permanent dipole moment tend to orient in the direction of the electric field at room temperature. The reorientation can be probed with the help of linear spectroscopy methods such as fluorescence anisotropy measurements. We have used nonlinear polarization sensitive Raman scattering spectroscopy to quantify the orientation effect of the dipoles. Vibrational spectra of the molecules has been recorded as a function of the external electric field. The polarization changes observed during the measurement are directly linked to the molecular reorientation rearrangement. Spectra has been recorded with a laser spectrometer comprised of a Nd:YAG laser and an optical parametric oscillator and an imaging spectrometer with a CCD detector. In order to make this measurement we have constructed a glass capacitor cell coated in TiO and applied a significant electric field (0-3 kV/mm) to the sample. Our measurements showed that the orientation effect is most significant for liquid crystals as observed previously with non-polarization sensitive CARS spectroscopy.

  2. LCD panel characterization by measuring full Jones matrix of individual pixels using polarization-sensitive digital holographic microscopy.

    Science.gov (United States)

    Park, Jongchan; Yu, Hyeonseung; Park, Jung-Hoon; Park, YongKeun

    2014-10-06

    We present measurements of the full Jones matrix of individual pixels in a liquid-crystal display (LCD) panel. Employing a polarization-sensitive digital holographic microscopy based on Mach-Zehnder interferometry, the complex amplitudes of the light passing through individual LCD pixels are precisely measured with respect to orthogonal bases of polarization states, from which the full Jones matrix components of individual pixels are obtained. We also measure the changes in the Jones matrix of individual LCD pixels with respect to an applied bias. In addition, the complex optical responses of a LCD panel with respect to arbitrary polarization states of incident light were characterized from the measured Jones matrix.

  3. Polarization sensitive changes in the human macula associated with normal aging and age-related macular degeneration

    Science.gov (United States)

    VanNasdale, Dean Allan, Jr.

    2011-12-01

    The human macula occupies a relatively small, but crucial retinal area, as it is the location responsible for our most acute spatial vision and best color discrimination. Localizing important landmarks in the retina is difficult even in normal eyes where morphological inter-individual variability is high. This becomes even more challenging in the presence of sight-threatening pathology. With respect to the human macula, there remains a significant gap in the understanding of normal structure and function. Even less is known about the pathological mechanisms that occur in sight-threatening diseases including age-related macular degeneration. Because relatively little is known about normal aging changes, it is also difficult to differentiate those changes from changes associated with retinal disease. To better understand normal and pathological changes in the macula, imaging techniques using specific optical signatures are required. Structural features in the macula can be distinguished based on their intrinsic properties using specific light/tissue interactions. Because of the high degree of structural regularity in the macula, polarization sensitive imaging is potentially a useful tool for evaluating the morphology and integrity of the cellular architecture for both normal individuals and those affected by disease. In our investigations, we used polarization sensitive imaging to determining normal landmarks that are important clinically and for research investigations. We found that precision and accuracy in localizing the central macula was greatly improved through the use of polarization sensitive imaging. We also found that specific polarization alterations can be used to demonstrate systematic changes as a function of age, disproportionately affecting the central macular region. When evaluating patients with age-related macular degeneration, we found that precision and accuracy of localizing the central macula was also improved, even when significant pathology

  4. Enhanced monolithic diffraction gratings with high efficiency and reduced polarization sensitivity for remote sensing applications

    Science.gov (United States)

    Triebel, Peter; Diehl, Torsten; Moeller, Tobias; Gatto, Alexandre; Pesch, Alexander; Erdmann, Lars H.; Burkhardt, Matthias; Kalies, Alexander

    2015-10-01

    distribution. Beside of the results of straylight measurement the actual results on improving efficiency and lowering the polarization sensitivity for transmission gratings will be discussed on theoretical simulations compared to measured data over the entire wavelength range.

  5. Automated Identification and Quantification of Subretinal Fibrosis in Neovascular Age-Related Macular Degeneration Using Polarization-Sensitive OCT.

    Science.gov (United States)

    Roberts, Philipp; Sugita, Mitsuro; Deák, Gábor; Baumann, Bernhard; Zotter, Stefan; Pircher, Michael; Sacu, Stefan; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2016-04-01

    To identify and quantify subretinal fibrosis in eyes with advanced neovascular age-related macular degeneration (nAMD) using polarization-sensitive optical coherence tomography (PS-OCT). Eyes of patients with subretinal fibrosis secondary to nAMD were included in this case series. All patients underwent a complete ophthalmic examination to clearly identify advanced nAMD lesions with fibrosis. Examinations of PS-OCT were performed using a novel system with an integrated eye tracker. Areas of fibrosis in PS-OCT, automatically segmented using a custom-built algorithm, were compared with conventional imaging modalities including spectral-domain OCT, fluorescein angiography, and color fundus photography in their potential to visualize fibrosis in nAMD. Fifteen eyes of 15 consecutive patients were included. In polarization-sensitive OCT B-scans, a distinct "column-like" pattern was observed in averaged axis orientation images. En face analysis provided a precise mapping of the fibrotic scar component. Fibrous tissue was selectively identified by PS-OCT based on birefringence in all lesions, whereas in SD-OCT, subretinal hyperreflective material (SHRM) could not be further classified into scar tissue, fibrovascular material, or other AMD-specific material. Based on simultaneous polarization analyses in PS-OCT, the level of RPE alteration could be evaluated as well, showing thinning and loss of RPE associated with subretinal fibrosis. Using PS-OCT, subretinal fibrosis can be identified as an intrinsically birefringent structure and can be segmented based solely on tissue-specific contrast. Polarization-sensitive OCT offers a unique method to identify clinically relevant components of SHRM (i.e., neovascular tissue versus fibrous tissue) and therefore allows for an optimized disease management and evaluation of therapeutic strategies.

  6. Accurate and quantitative polarization-sensitive OCT by unbiased birefringence estimator with noise-stochastic correction

    Science.gov (United States)

    Kasaragod, Deepa; Sugiyama, Satoshi; Ikuno, Yasushi; Alonso-Caneiro, David; Yamanari, Masahiro; Fukuda, Shinichi; Oshika, Tetsuro; Hong, Young-Joo; Li, En; Makita, Shuichi; Miura, Masahiro; Yasuno, Yoshiaki

    2016-03-01

    Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that contrasts the polarization properties of tissues. It has been applied to ophthalmology, cardiology, etc. Proper quantitative imaging is required for a widespread clinical utility. However, the conventional method of averaging to improve the signal to noise ratio (SNR) and the contrast of the phase retardation (or birefringence) images introduce a noise bias offset from the true value. This bias reduces the effectiveness of birefringence contrast for a quantitative study. Although coherent averaging of Jones matrix tomography has been widely utilized and has improved the image quality, the fundamental limitation of nonlinear dependency of phase retardation and birefringence to the SNR was not overcome. So the birefringence obtained by PS-OCT was still not accurate for a quantitative imaging. The nonlinear effect of SNR to phase retardation and birefringence measurement was previously formulated in detail for a Jones matrix OCT (JM-OCT) [1]. Based on this, we had developed a maximum a-posteriori (MAP) estimator and quantitative birefringence imaging was demonstrated [2]. However, this first version of estimator had a theoretical shortcoming. It did not take into account the stochastic nature of SNR of OCT signal. In this paper, we present an improved version of the MAP estimator which takes into account the stochastic property of SNR. This estimator uses a probability distribution function (PDF) of true local retardation, which is proportional to birefringence, under a specific set of measurements of the birefringence and SNR. The PDF was pre-computed by a Monte-Carlo (MC) simulation based on the mathematical model of JM-OCT before the measurement. A comparison between this new MAP estimator, our previous MAP estimator [2], and the standard mean estimator is presented. The comparisons are performed both by numerical simulation and in vivo measurements of anterior and

  7. High-resolution retinal swept source optical coherence tomography with an ultra-wideband Fourier-domain mode-locked laser at MHz A-scan rates.

    Science.gov (United States)

    Kolb, Jan Philip; Pfeiffer, Tom; Eibl, Matthias; Hakert, Hubertus; Huber, Robert

    2018-01-01

    We present a new 1060 nm Fourier domain mode locked laser (FDML laser) with a record 143 nm sweep bandwidth at 2∙ 417 kHz  =  834 kHz and 120 nm at 1.67 MHz, respectively. We show that not only the bandwidth alone, but also the shape of the spectrum is critical for the resulting axial resolution, because of the specific wavelength-dependent absorption of the vitreous. The theoretical limit of our setup lies at 5.9 µm axial resolution. In vivo MHz-OCT imaging of human retina is performed and the image quality is compared to the previous results acquired with 70 nm sweep range, as well as to existing spectral domain OCT data with 2.1 µm axial resolution from literature. We identify benefits of the higher resolution, for example the improved visualization of small blood vessels in the retina besides several others.

  8. Insect remote sensing using a polarization sensitive cw lidar system in chinese rice fields

    Directory of Open Access Journals (Sweden)

    Zhu Shiming

    2018-01-01

    Full Text Available A joint Chinese-Swedish field campaign of Scheimpflug continuous-wave lidar monitoring of rice-field flying pest insects was pursued in very hot July weather conditions close to Guangzhou, China. The occurrence of insects, birds and bats with almost 200 hours of round-the-clock polarization-sensitive recordings was studied. Wing-beat frequency recordings and depolarization properties were used for target classification. Influence of weather conditions on the flying fauna was also investigated.

  9. Chip based common-path optical coherence tomography system with an on-chip microlens and multi-reference suppression algorithm

    NARCIS (Netherlands)

    Chang, Lantian; Weiss, Nicolás; van Leeuwen, Ton G.; Pollnau, Markus; de Ridder, René M.; Wörhoff, Kerstin; Subramaniam, Vinod; Kanger, Johannes S.

    2016-01-01

    We demonstrate an integrated optical probe including an on-chip microlens for a common-path swept-source optical coherence tomography system. This common-path design uses the end facet of the silicon oxynitride waveguide as the reference plane, thus eliminating the need of a space-consuming and

  10. Chip based common-path optical coherence tomography system with an on-chip microlens and multi-reference suppresion algorithm

    NARCIS (Netherlands)

    Chang, Lantian; Weiss, Nicolas; van Leeuwen, Ton; Pollnau, Markus; de Ridder, R.M.; Worhoff, Kerstin; Subramaniam, Vinod; Kanger, Johannes S.

    2016-01-01

    We demonstrate an integrated optical probe including an on-chip microlens for a common-path swept-source optical coherence tomography system. This common-path design uses the end facet of the silicon oxynitride waveguide as the reference plane, thus eliminating the need of a space-consuming and

  11. High resolution feature extraction from optical coherence tomography acquired internal fingerprint

    CSIR Research Space (South Africa)

    Khutlang, Rethabile

    2016-05-01

    Full Text Available Biometric fingerprint scanners scan the external skin features onto a 2D image. The performance of the automatic fingerprint identification system suffers if the finger skin is wet, worn out, fake fingerprint is used et cetera. Swept source optical...

  12. Broadband Fourier domain mode-locked laser for optical coherence tomography at 1060 nm

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2012-01-01

    , enable acquisition of densely sampled three-dimensional datasets covering a wide field of view. However, semiconductor optical amplifiers (SOAs)-the typical laser gain media for swept sources-for the 1060nm band could until recently only provide relatively low output power and bandwidth. We have...

  13. Optimization of s-Polarization Sensitivity in Apertureless Near-Field Optical Microscopy

    Directory of Open Access Journals (Sweden)

    Yuika Saito

    2012-01-01

    Full Text Available It is a general belief in apertureless near-field microscopy that the so-called p-polarization configuration, where the incident light is polarized parallel to the axis of the probe, is advantageous to its counterpart, the s-polarization configuration, where the incident light is polarized perpendicular to the probe axis. While this is true for most samples under common near-field experimental conditions, there are samples which respond better to the s-polarization configuration due to their orientations. Indeed, there have been several reports that have discussed such samples. This leads us to an important requirement that the near-field experimental setup should be equipped with proper sensitivity for measurements with s-polarization configuration. This requires not only creation of effective s-polarized illumination at the near-field probe, but also proper enhancement of s-polarized light by the probe. In this paper, we have examined the s-polarization enhancement sensitivity of near-field probes by measuring and evaluating the near-field Rayleigh scattering images constructed by a variety of probes. We found that the s-polarization enhancement sensitivity strongly depends on the sharpness of the apex of near-field probes. We have discussed the efficient value of probe sharpness by considering a balance between the enhancement and the spatial resolution, both of which are essential requirements of apertureless near-field microscopy.

  14. Demonstration of polarization sensitivity of emulsion-based pair conversion telescope for cosmic gamma-ray polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Keita, E-mail: ozaki@radix.h.kobe-u.ac.jp [Kobe University, 3-11, Tsurukabuto, Nada-ku, Kobe 657-8501 (Japan); Takahashi, Satoru, E-mail: satoru@radix.h.kobe-u.ac.jp [Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602 (Japan); Aoki, Shigeki; Kamada, Keiki; Kaneyama, Taichi; Nakagawa, Ryo; Rokujo, Hiroki [Kobe University, 3-11, Tsurukabuto, Nada-ku, Kobe 657-8501 (Japan)

    2016-10-11

    Linear polarization of high-energy gamma-rays (10MeV–100 GeV) can be detected by measuring the azimuthal angle of electron–positron pairs and observing the modulation of the azimuthal distribution. To demonstrate the gamma-ray polarization sensitivity of emulsion, we conducted a test using a polarized gamma-ray beam (0.8–2.4 GeV) at SPring-8/LEPS. Emulsion tracks were reconstructed using scanning data, and gamma-ray events were selected automatically. Using an optical microscope, out of the 2381 gamma-ray conversions that were observed, 1372 remained after event selection, on the azimuthal angle distribution of which we measured the modulation. From the distribution of the azimuthal angles of the selected events, a modulation factor of 0.21+0.11−0.09 was measured, from which the detection of a non-zero modulation was established with a significance of 3.06σ. This attractive polarimeter will be applied to the GRAINE project, a balloon-borne experiment that observes 10–100 GeV cosmic gamma-rays with an emulsion-based pair conversion telescope.

  15. Adjustments to the MODIS Terra Radiometric Calibration and Polarization Sensitivity in the 2010 Reprocessing

    Science.gov (United States)

    Meister, Gerhard; Franz, Bryan A.

    2011-01-01

    The Moderate-Resolution Imaging Spectroradiometer (MODIS) on NASA s Earth Observing System (EOS) satellite Terra provides global coverage of top-of-atmosphere (TOA) radiances that have been successfully used for terrestrial and atmospheric research. The MODIS Terra ocean color products, however, have been compromised by an inadequate radiometric calibration at the short wavelengths. The Ocean Biology Processing Group (OBPG) at NASA has derived radiometric corrections using ocean color products from the SeaWiFS sensor as truth fields. In the R2010.0 reprocessing, these corrections have been applied to the whole mission life span of 10 years. This paper presents the corrections to the radiometric gains and to the instrument polarization sensitivity, demonstrates the improvement to the Terra ocean color products, and discusses issues that need further investigation. Although the global averages of MODIS Terra ocean color products are now in excellent agreement with those of SeaWiFS and MODIS Aqua, and image quality has been significantly improved, the large corrections applied to the radiometric calibration and polarization sensitivity require additional caution when using the data.

  16. Segmentation of forensic latent fingerprint images lifted contact-less from planar surfaces with optical cohererence tomography

    CSIR Research Space (South Africa)

    Khutlang, R

    2015-07-01

    Full Text Available an automatic segmentation of latent fingerprint images lifted contact-less from planar surfaces using swept source optical coherence tomography. We do not perform any localization scans as we know the position of fingerprint impressions left on a substrate...

  17. Acquisition of the polarity sensitive item renhe 'any' in Mandarin Chinese.

    Science.gov (United States)

    Huang, Aijun; Crain, Stephen

    2014-07-01

    The present study investigated Mandarin-speaking children's acquisition of the polarity sensitive item renhe 'any' in Mandarin Chinese. Like its English counterpart any, renhe can be used as a negative polarity item (NPI), or as a free choice (FC) item, and both the distribution and interpretation of renhe are governed by the same syntactic and semantic constraints as English any. Using a Truth Value Judgment Task, the present study tested five-year-old Mandarin-speaking children's comprehension of FC renhe in sentences containing the modal word neng 'can', and tested children's comprehension of NPI renhe in sentences containing the temporal conjunction zai…zhiqian 'before'. Most children demonstrated knowledge of the interpretation of both FC renhe and NPI renhe despite a paucity of relevant adult input. Like adults, however, Mandarin-speaking children do not use renhe frequently in ordinary conversation, due to the availability of alternative colloquial expressions (wh-pronouns) that also convey children's intended meanings.

  18. Simple Unbiased Hot-Electron Polarization-Sensitive Near-Infrared Photodetector.

    Science.gov (United States)

    Mirzaee, Somayeh M A; Lebel, Olivier; Nunzi, Jean-Michel

    2018-03-27

    Plasmonic nanostructures can generate energetic "hot" electrons from light in a broad band fashion depending on their shape, size, and arrangement. Such structures have a promising use in photodetectors, allowing high speed, broad band, and multicolor photodetection. Because they function without a band gap absorption, photon detection at any energy would be possible through engineering of the plasmonic nanostructure. Herein, a compact hot-electron-based photodetector that combines polarization sensitivity and circularly polarized light detection in the near-infrared region was fabricated using an indium tin oxide (ITO)-Au hybrid layer. Furthermore, the sensitivity of the device was significantly increased by adding a poled Azo molecular glass film in a capacitor configuration. The resulting device is capable of detecting light below the ITO band gap at ambient temperature without any bias voltage. This photodetector, which is amenable to large-area fabrication, can be integrated with other nanophotonic and nanoplasmonic structures for operation at telecom wavelengths.

  19. Polarization sensitivity of light diffraction for periodic array of anisotropic gold nanoparticles

    International Nuclear Information System (INIS)

    Tsai, Ming-shan; Liu, Tung-kai; Tsen, Chun-yu; Ting, Chen-ching

    2015-01-01

    This article aims to analyze the first order diffraction intensity of the incident polarized light which is diffracted by the gold nanoparticles array in terms of the surface plasmon effect. The inspected gold nanoparticles array films are built in grating pattern with stripe thickness of 4 μm and diameters of gold nanoparticles ca. 10–56 nm, which are formed by annealing at temperatures of 400, 450, 500, and 550 °C, respectively. The probing light is linearly polarized with wavelengths of 450–800 nm and counterclockwise turns its polarization direction from 0° to 90° during measurements. The results show that the diffraction intensity depends on the anisotropic configuration samples which gold nanoparticles are orientated by analyzing the scanning electron microscope images. It results that the localized surface plasmon effect induced by incident field depends on orientation and causes the sample polarization-sensitive

  20. Scalable Background-Limited Polarization-Sensitive Detectors for mm-wave Applications

    Science.gov (United States)

    Rostem, Karwan; Ali, Aamir; Appel, John W.; Bennett, Charles L.; Chuss, David T.; Colazo, Felipe A.; Crowe, Erik; Denis, Kevin L.; Essinger-Hileman, Tom; Marriage, Tobias A.; hide

    2014-01-01

    We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.

  1. A Low-Complexity DOA and Polarization Method of Polarization-Sensitive Array

    Directory of Open Access Journals (Sweden)

    Wen Dong

    2017-05-01

    Full Text Available This paper proposes a low-complexity method to estimate the direction of arrival and polarization based on the polarization sensitive array (PSA which is composed of cross-dipoles. We built a half-quaternions model through the Cayley–Dickson form to remove the redundant information. Then, the directions of arrival (DOAs were estimated via the root-MUSIC algorithm. Finally, the polarizations were estimated by generalized eigenvalue method. Unlike some existing searching algorithms, such as multiple signal classification (MUSIC, this method can avoid the peak searching and maintains high estimation accuracy. Moreover, we use the oblique projection operators to filter out the interference signals which are decoys of the target signal. Simulation results demonstrate the effectiveness and favorable performance of the proposed method.

  2. Suomi National Polar-Orbiting Partnership Visible Infrared Imaging Radiometer Suite Polarization Sensitivity Analysis

    Science.gov (United States)

    Sun, Junqiang; Xiong, Xiaoxiong; Waluschka, Eugene; Wang, Menghua

    2016-01-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) is one of five instruments onboard the Suomi National Polar-Orbiting Partnership (SNPP) satellite that launched from Vandenberg Air Force Base, California, on October 28, 2011. It is a whiskbroom radiometer that provides +/-56.28deg scans of the Earth view. It has 22 bands, among which 14 are reflective solar bands (RSBs). The RSBs cover a wavelength range from 410 to 2250 nm. The RSBs of a remote sensor are usually sensitive to the polarization of incident light. For VIIRS, it is specified that the polarization factor should be smaller than 3% for 410 and 862 nm bands and 2.5% for other RSBs for the scan angle within +/-45deg. Several polarization sensitivity tests were performed prelaunch for SNPP VIIRS. The first few tests either had large uncertainty or were less reliable, while the last one was believed to provide the more accurate information about the polarization property of the instrument. In this paper, the measured data in the last polarization sensitivity test are analyzed, and the polarization factors and phase angles are derived from the measurements for all the RSBs. The derived polarization factors and phase angles are band, detector, and scan angle dependent. For near-infrared bands, they also depend on the half-angle mirror side. Nevertheless, the derived polarization factors are all within the specification, although the strong detector dependence of the polarization parameters was not expected. Compared to the Moderate Resolution Imaging Spectroradiometer on both Aqua and Terra satellites, the polarization effect on VIIRS RSB is much smaller.

  3. Real time en face Fourier-domain optical coherence tomography with direct hardware frequency demodulation

    OpenAIRE

    Biedermann, Benjamin R.; Wieser, Wolfgang; Eigenwillig, Christoph M.; Palte, Gesa; Adler, Desmond C.; Srinivasan, Vivek J.; Fujimoto, James G.; Huber, Robert

    2008-01-01

    We demonstrate en face swept source optical coherence tomography (ss-OCT) without requiring a Fourier transformation step. The electronic optical coherence tomography (OCT) interference signal from a k-space linear Fourier domain mode-locked laser is mixed with an adjustable local oscillator, yielding the analytic reflectance signal from one image depth for each frequency sweep of the laser. Furthermore, a method for arbitrarily shaping the spectral intensity profile of the laser is presented...

  4. Aerosol characteristics in Phimai, Thailand determined by continuous observation with a polarization sensitive Mie–Raman lidar and a sky radiometer

    International Nuclear Information System (INIS)

    Sugimoto, Nobuo; Shimizu, Atsushi; Nishizawa, Tomoaki; Matsui, Ichiro; Jin, Yoshitaka; Khatri, Pradeep; Irie, Hitoshi; Takamura, Tamio; Aoki, Kazuma; Thana, Boossarasiri

    2015-01-01

    Distributions and optical characteristics of aerosols were continuously observed with a polarization-sensitive (532 nm), Mie-scattering (532 and 1064 nm) and Raman-scattering (607 nm) lidar and a sky radiometer in Phimai, Thailand. Polarization lidar measurements indicated that high concentration plumes of spherical aerosols considered as biomass burning smoke were often observed in the dry season. Plumes of non-spherical aerosols considered as long-range transported soil dust from Africa, the Middle East, or Northeast Asia were occasionally observed. Furthermore, low-concentration non-spherical aerosols were almost always observed in the atmospheric mixing layer. Extinction coefficient profiles of spherical aerosols and non-spherical dust exhibited different diurnal variations, and spherical aerosols including smoke were distributed in higher altitudes in the mixing layer and residual layer. The difference can be explained by hygroscopic growth of smoke particles and buoyancy of the smoke. Analysis of seasonal variations of optical properties derived from the Raman lidar and the sky radiometer confirmed that the lidar ratio, aerosol optical depth, and Angstrom exponent were higher in the dry season (October–May) and lower in the wet season (June–September). The single scattering albedo was lower in the dry season. These seasonal variations are explained by frequent biomass burning in the dry season consistent with previous studies in Southeast Asian region. At the same time, the present work confirmed that soil dust was a major aerosol component in Phimai, Thailand. (letter)

  5. Polarity-sensitive nanocarrier for oral delivery of Sb(V and treatment of cutaneous leishmaniasis

    Directory of Open Access Journals (Sweden)

    Lanza JS

    2016-05-01

    remarkable property of these nanoassemblies, as revealed by AFM analysis, is the flexibility of their supramolecular organization, which showed changes as a function of the solvent and substrate polarities. The formulation of SbL8 in 1:1 water:PG given orally to mice promoted significantly higher and more sustained serum levels of Sb, when compared to SbL8 in water. The new formulation, when given as repeated doses (200 mg Sb/kg/day to BALB/c mice infected with Leishmania amazonensis, was significantly more effective in reducing the lesion parasite burden, compared to SbL8 in water, and even, the conventional drug Glucantime® given intraperitoneally at the same dose. In conclusion, this work introduces a new concept of polarity-sensitive nanocarrier that was successfully applied to optimize an oral formulation of Sb(V for treating cutaneous leishmaniasis. Keywords: propylene glycol, antimony, Leishmania amazonensis, AFM, amphiphilic complex, SAXS

  6. Four-dimensional Microscope-Integrated Optical Coherence Tomography to Visualize Suture Depth in Strabismus Surgery.

    Science.gov (United States)

    Pasricha, Neel D; Bhullar, Paramjit K; Shieh, Christine; Carrasco-Zevallos, Oscar M; Keller, Brenton; Izatt, Joseph A; Toth, Cynthia A; Freedman, Sharon F; Kuo, Anthony N

    2017-02-14

    The authors report the use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT), capable of live four-dimensional (three-dimensional across time) intraoperative imaging, to directly visualize suture depth during lateral rectus resection. Key surgical steps visualized in this report included needle depth during partial and full-thickness muscle passes along with scleral passes. [J Pediatr Ophthalmol Strabismus. 2017;54:e1-e5.]. Copyright 2017, SLACK Incorporated.

  7. Non-Destructive Inspection Methods for LEDs Using Real-Time Displaying Optical Coherence Tomography

    OpenAIRE

    Suhwan Kim; Jeehyun Kim; Unsang Jung; Nam Hyun Cho

    2012-01-01

    In this study, we report the applicability of two different Optical Coherence Tomography (OCT) technologies for inspecting Light Emitting Diode (LED) structures. Sectional images of a LED were captured using a Spectral Domain OCT (SD-OCT) system and a Swept Source OCT (SS-OCT) system. Their center wavelengths are 850 and 1,310 nm, respectively. We acquired cross-sectional two dimensional (2D) images of a normal LED and extracted sectional profiles to inspect possible wire disconnection that m...

  8. Intersubband absorption in annealed InAs/GaAs quantum dots: a case for polarization-sensitive infrared detection

    International Nuclear Information System (INIS)

    Chakrabarti, S; Bhattacharya, P; Stiff-Roberts, A D; Lin, Y Y; Singh, J; Lei, Y; Browning, N

    2003-01-01

    We have studied the characteristics of intersubband absorption of polarized infrared (IR) radiation in as-grown and annealed self-organized InAs/GaAs quantum dots. It is observed that with the increase of annealing time and temperature, the dots tend to flatten and behave more like quantum wells. As a result, their sensitivity to TE (in-plane)-polarized light decreases and that to TM (out-of-plane)-polarized light increases. The effect could be utilized for the realization of polarization-sensitive IR detectors

  9. Ball Lens Fiber Optic Sensor based Smart Handheld Microsurgical Instrument.

    Science.gov (United States)

    Song, Cheol; Gehlbach, Peter L; Kang, Jin U

    2013-03-20

    During freehand performance of vitreoretinal microsurgery the surgeon must perform precise and stable maneuvers that achieve surgical objectives and avoid surgical risk. Here, we present an improved smart handheld microsurgical tool which is based on a ball lens fiber optic sensor that utilizes common path swept source optical coherence tomography. Improvements include incorporation of a ball lens single mode fiber optic probe that increases the working angle of the tool to greater than 45 degrees; and increases the magnitude of the distance sensing signal through water. Also presented is a cutting function with an improved ergonomic design.

  10. Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography.

    Science.gov (United States)

    Huber, R; Wojtkowski, M; Fujimoto, J G

    2006-04-17

    We demonstrate a new technique for frequency-swept laser operation--Fourier domain mode locking (FDML)--and its application for swept-source optical coherence tomography (OCT) imaging. FDML is analogous to active laser mode locking for short pulse generation, except that the spectrum rather than the amplitude of the light field is modulated. High-speed, narrowband optical frequency sweeps are generated with a repetition period equal to the fundamental or a harmonic of cavity round-trip time. An FDML laser is constructed using a long fiber ring cavity, a semiconductor optical amplifier, and a tunable fiber Fabry-Perot filter. Effective sweep rates of up to 290 kHz are demonstrated with a 105 nm tuning range at 1300 nm center wavelength. The average output power is 3mW directly from the laser and 20 mW after post-amplification. Using the FDML laser for swept-source OCT, sensitivities of 108 dB are achieved and dynamic linewidths are narrow enough to enable imaging over a 7 mm depth with only a 7.5 dB decrease in sensitivity. We demonstrate swept-source OCT imaging with acquisition rates of up to 232,000 axial scans per second. This corresponds to 906 frames/second with 256 transverse pixel images, and 3.5 volumes/second with a 256x128x256 voxel element 3-DOCT data set. The FDML laser is ideal for swept-source OCT imaging, thus enabling high imaging speeds and large imaging depths.

  11. Quantitative assessment of rat corneal thickness and morphology during stem cell therapy by high-speed optical coherence tomography

    Science.gov (United States)

    Lal, Cerine; McGrath, James; Subhash, Hrebesh; Rani, Sweta; Ritter, Thomas; Leahy, Martin

    2016-03-01

    Optical Coherence Tomography (OCT) is a non-invasive 3 dimensional optical imaging modality that enables high resolution cross sectional imaging in biological tissues and materials. Its high axial and lateral resolution combined with high sensitivity, imaging depth and wide field of view makes it suitable for wide variety of high resolution medical imaging applications at clinically relevant speed. With the advent of swept source lasers, the imaging speed of OCT has increased considerably in recent years. OCT has been used in ophthalmology to study dynamic changes occurring in the cornea and iris, thereby providing physiological and pathological changes that occur within the anterior segment structures such as in glaucoma, during refractive surgery, lamellar keratoplasty and corneal diseases. In this study, we assess the changes in corneal thickness in the anterior segment of the eye during wound healing process in a rat corneal burn model following stem cell therapy using high speed swept source OCT.

  12. d-PET-controlled “off-on” Polarity-sensitive Probes for Reporting Local Hydrophilicity within Lysosomes

    Science.gov (United States)

    Zhu, Hao; Fan, Jiangli; Mu, Huiying; Zhu, Tao; Zhang, Zhen; Du, Jianjun; Peng, Xiaojun

    2016-10-01

    Polarity-sensitive fluorescent probes are powerful chemical tools for studying biomolecular structures and activities both in vitro and in vivo. However, the lack of “off-on” polarity-sensing probes has limited the accurate monitoring of biological processes that involve an increase in local hydrophilicity. Here, we design and synthesize a series of “off-on” polarity-sensitive fluorescent probes BP series consisting of the difluoroboron dippyomethene (BODIPY) fluorophore connected to a quaternary ammonium moiety via different carbon linkers. All these probes showed low fluorescence quantum yields in nonpolar solution but became highly fluorescent in polar media. BP-2, which contains a two-carbon linker and a trimethyl quaternary ammonium, displayed a fluorescence intensity and quantum yield that were both linearly correlated with solvent polarity. In addition, BP-2 exhibited high sensitivity and selectivity for polarity over other environmental factors and a variety of biologically relevant species. BP-2 can be synthesized readily via an unusual Mannich reaction followed by methylation. Using electrochemistry combined with theoretical calculations, we demonstrated that the “off-on” sensing behavior of BP-2 is primarily due to the polarity-dependent donor-excited photoinduced electron transfer (d-PET) effect. Live-cell imaging established that BP-2 enables the detection of local hydrophilicity within lysosomes under conditions of lysosomal dysfunction.

  13. Polarization-Sensitive Hyperspectral Imaging in vivo: A Multimode Dermoscope for Skin Analysis

    Science.gov (United States)

    Vasefi, Fartash; MacKinnon, Nicholas; Saager, Rolf B.; Durkin, Anthony J.; Chave, Robert; Lindsley, Erik H.; Farkas, Daniel L.

    2014-05-01

    Attempts to understand the changes in the structure and physiology of human skin abnormalities by non-invasive optical imaging are aided by spectroscopic methods that quantify, at the molecular level, variations in tissue oxygenation and melanin distribution. However, current commercial and research systems to map hemoglobin and melanin do not correlate well with pathology for pigmented lesions or darker skin. We developed a multimode dermoscope that combines polarization and hyperspectral imaging with an efficient analytical model to map the distribution of specific skin bio-molecules. This corrects for the melanin-hemoglobin misestimation common to other systems, without resorting to complex and computationally intensive tissue optical models. For this system's proof of concept, human skin measurements on melanocytic nevus, vitiligo, and venous occlusion conditions were performed in volunteers. The resulting molecular distribution maps matched physiological and anatomical expectations, confirming a technologic approach that can be applied to next generation dermoscopes and having biological plausibility that is likely to appeal to dermatologists.

  14. In-line optical fiber metallic mirror reflector for monolithic common path optical coherence tomography probes.

    Science.gov (United States)

    Singh, Kanwarpal; Reddy, Rohith; Sharma, Gargi; Verma, Yogesh; Gardecki, Joseph A; Tearney, Guillermo

    2018-03-01

    Endoscopic optical coherence tomography probes suffer from various artifacts due to dispersion imbalance and polarization mismatch between reference and sample arm light. Such artifacts can be minimized using a common path approach. In this work, we demonstrate a miniaturized common path probe for optical coherence tomography using an inline fiber mirror. A common path optical fiber probe suitable for performing high-resolution endoscopic optical coherence tomography imaging was developed. To achieve common path functionality, an inline fiber mirror was fabricated using a thin gold layer. A commercially available swept source engine was used to test the designed probe in a cadaver human coronary artery ex vivo. We achieved a sensitivity of 104 dB for this probe using a swept source optical coherence tomography system. To test the probe, images of a cadaver human coronary artery were obtained, demonstrating the quality that is comparable to those obtained by OCT systems with separate reference arms. Additionally, we demonstrate recovery of ranging depth by use of a Michelson interferometer in the detection path. We developed a miniaturized monolithic inline fiber mirror-based common path probe for optical coherence tomography. Owing to its simplicity, our design will be helpful in endoscopic applications that require high-resolution probes in a compact form factor while reducing system complexity. Lasers Surg. Med. 50:230-235, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. Nanoparticles displacement analysis using optical coherence tomography

    Science.gov (United States)

    StrÄ kowski, Marcin R.; Kraszewski, Maciej; StrÄ kowska, Paulina

    2016-03-01

    Optical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits of using the combination of timefrequency and polarization sensitive analysis are being expressed. The usefulness of PS-SOCT for nanoparticles evaluation is going to be tested on nanocomposite materials with TiO2 nanoparticles. The OCT measurements results have been compared with SEM examination of the PMMA matrix with nanoparticles. The experiment has proven that by the use of polarization sensitive and spectroscopic OCT the nanoparticles dispersion and size can be evaluated.

  16. High-speed, high-resolution optical coherence tomography retinal imaging with a frequency-swept laser at 850 nm.

    Science.gov (United States)

    Srinivasan, V J; Huber, R; Gorczynska, I; Fujimoto, J G; Jiang, J Y; Reisen, P; Cable, A E

    2007-02-15

    High-speed, high-resolution optical coherence tomography (OCT) imaging of the human retina is demonstrated using a frequency-swept laser at 850 nm. A compact external cavity semiconductor laser design, optimized for swept-source ophthalmic OCT, is described. The laser enables an effective 16 kHz sweep rate with >10 mm coherence length and a tuning range of approximately 35 nm full width at half-maximum, yielding an axial resolution of <7 micro m in tissue.

  17. Gabor fusion master slave optical coherence tomography

    DEFF Research Database (Denmark)

    Cernat, Ramona; Bradu, Adrian; Israelsen, Niels Møller

    2017-01-01

    This paper describes the application of the Gabor filtering protocol to a Master/Slave (MS) swept source optical coherence tomography (SS)-OCT system at 1300 nm. The MS-OCT system delivers information from selected depths, a property that allows operation similar to that of a time domain OCT system...... of interest. By combining the two techniques, Gabor filtering and Master/Slave, a powerful imaging instrument is demonstrated. The master/slave technique allows simultaneous display of three categories of images in one frame: multiple depth en-face OCT images, two cross-sectional OCT images and a confocal...

  18. Optical coherence tomography detection of shear wave propagation in MCF7 cell modules

    Science.gov (United States)

    Razani, Marjan; Mariampillai, Adrian; Berndl, Elizabeth S. L.; Kiehl, Tim-Rasmus; Yang, Victor X. D.; Kolios, Michael C.

    2014-02-01

    In this work, we explored the potential of measuring shear wave propagation using Optical Coherence Elastography (OCE) in MCF7 cell modules (comprised of MCF7 cells and collagen) and based on a swept-source optical coherence tomography (OCT) system. Shear waves were generated using a piezoelectric transducer transmitting sine-wave bursts of 400 μs, synchronized with an OCT swept source wavelength sweep imaging system. Acoustic radiation force was applied to the MCF7 cell constructs. Differential OCT phase maps, measured with and without the acoustic radiation force, demonstrate microscopic displacement generated by shear wave propagation in these modules. The OCT phase maps are acquired with a swept-source OCT (SS-OCT) system. We also calculated the tissue mechanical properties based on the propagating shear waves in the MCF7 + collagen phantoms using the Acoustic Radiation Force (ARF) of an ultrasound transducer, and measured the shear wave speed with the OCT phase maps. This method lays the foundation for future studies of mechanical property measurements of breast cancer structures, with applications in the study of breast cancer pathologies.

  19. Tunable polarization sensitive absorber made of graphene-based hyperbolic metamaterials

    Science.gov (United States)

    Madani, Amir; Babaei, Maryam

    2017-02-01

    Theoretically, the absorption properties of a hyperbolic metamaterial (HMM) slab constructed from graphene-dielectric multilayers are investigated using the transfer matrix method. The effective medium approximation reveals that the graphene-based HMM slab is an anisotropic and homogeneous medium. It is shown that the absorption of the slab depend on the polarization and incidence angle due to the strong anisotropy of the HMMs. The results revealed that the complete absorption is only possible for the TM-polarized waves in a broad region of wavelength. It is found that the region of total absorption can be controlled and tuned using some controlling parameters such as incidence angle, the orientation of the optical axis of the HMM medium and the chemical potential of the graphene monolayers. Finally, the intensity distribution of a TM-polarized Gaussian beam is simulated which verifies the strong absorption of the waves inside the HMM slab. This absorber may have potential applications in the design of tunable filters, polarizers, detectors, photovoltaic devices and so on.

  20. Light polarization sensitive photodetectors with m- and r-plane homoepitaxial ZnO/ZnMgO quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Tabares, G.; Hierro, A., E-mail: adrian.hierro@upm.es; Lopez-Ponce, M.; Muñoz, E. [ISOM and Dpto. Ingeniería Electrónica, Universidad Politécnica de Madrid, Ciudad Universitaria s/n, 28040 Madrid (Spain); Vinter, B.; Chauveau, J.-M. [CRHEA-CNRS, Av. B. Gregory, 06560 Valbonne (France); University of Nice Sophia Antipolis, Parc Valrose, 06102 Nice cedex 2 (France)

    2015-02-09

    Homoepitaxial ZnO/(Zn,Mg)O multiple quantum wells (MQWs) grown with m- and r-plane orientations are used to demonstrate Schottky photodiodes sensitive to the polarization state of light. In both orientations, the spectral photoresponse of the MQW photodiodes shows a sharp excitonic absorption edge at 3.48 eV with a very low Urbach tail, allowing the observation of the absorption from the A, B and C excitonic transitions. The absorption edge energy is shifted by ∼30 and ∼15 meV for the m- and r-plane MQW photodiodes, respectively, in full agreement with the calculated polarization of the A, B, and C excitonic transitions. The best figures of merit are obtained for the m-plane photodiodes, which present a quantum efficiency of ∼11%, and a specific detectivity D* of ∼6.4 × 10{sup 10} cm Hz{sup 1/2}/W. In these photodiodes, the absorption polarization sensitivity contrast between the two orthogonal in-plane axes yields a maximum value of (R{sub ⊥}/R{sub ||}){sub max} ∼ 9.9 with a narrow bandwidth of ∼33 meV.

  1. Anisotropic percolation conduction in elastomer-carbon black composites investigated by polarization-sensitive terahertz time-domain spectroscopy

    Science.gov (United States)

    Okano, Makoto; Fujii, Misako; Watanabe, Shinichi

    2017-11-01

    We investigated the draw ratio (DR) dependence of the anisotropic dielectric function and conductivity of styrene butadiene rubbers (SBRs) with different carbon black (CB) concentrations by polarization-sensitive terahertz time-domain spectroscopy. From the frequency dependence of the conductivity in the unstretched SBRs ranging from direct current to terahertz frequencies, it is found that the SBR with a CB concentration above 30 wt. % exhibits percolation conductivity. We investigated the spectral shape of the dielectric function and conductivity of the SBR samples below and above the percolation threshold for two representative DRs in the terahertz frequency region. We found that the DR dependence of the spectral shape is well explained by the effective medium approximation, except for the sample with the CB concentration above 30 wt. % under the unstretched condition. The conductivity in that sample remarkably changes in the low terahertz frequency region, which suggests a change in the CB network by deformation. The investigation of the dielectric anisotropy and percolation conductivity using our polarization technique can be applied to a wide range of elastomer composites.

  2. Microvascular changes during acne lesion initiation and scarring is revealed in vivo using optical microangiography

    Science.gov (United States)

    Baran, Utku; Li, Yuandong; Choi, Woo J.; Wang, Ruikang K.

    2015-02-01

    Acne is a common skin disease in society and often leads to scarring. In this paper, we demonstrate the capabilities of swept-source optical coherence tomography (SS-OCT) in detecting specific features of acne lesion initiation and scarring on human facial skin in vivo over 30 days. Optical microangiography (OMAG) technique made it possible to image 3D tissue microvasculature changes up to 1 mm depth in vivo without the need of exogenous contrast agents in ~10 seconds. The presented results show promise to facilitate clinical trials of treatment and prognosis of acne vulgaris by detecting cutaneous microvasculature and structural changes within human skin in vivo.

  3. In vivo endoscopic multi-beam optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Standish, Beau A; Mariampillai, Adrian; Munce, Nigel R; Leung, Michael K K; Vitkin, I Alex [Deptartment of Medical Biophysics, University of Toronto, Toronto (Canada); Lee, Kenneth K C; Yang, Victor X D [Ontario Cancer Institute/University Health Network, Toronto (Canada)], E-mail: standish@ee.ryerson.ca

    2010-02-07

    A multichannel optical coherence tomography (multi-beam OCT) system and an in vivo endoscopic imaging probe were developed using a swept-source OCT system. The distal optics were micro-machined to produce a high numerical aperture, multi-focus fibre optic array. This combination resulted in a transverse design resolution of <10 {mu}m full width half maximum (FWHM) throughout the entire imaging range, while also increasing the signal intensity within the focus of the individual channels. The system was used in a pre-clinical rabbit study to acquire in vivo structural images of the colon and ex vivo images of the oesophagus and trachea. A good correlation between the structural multi-beam OCT images and H and E histology was achieved, demonstrating the feasibility of this high-resolution system and its potential for in vivo human endoscopic imaging.

  4. In vivo endoscopic multi-beam optical coherence tomography

    International Nuclear Information System (INIS)

    Standish, Beau A; Mariampillai, Adrian; Munce, Nigel R; Leung, Michael K K; Vitkin, I Alex; Lee, Kenneth K C; Yang, Victor X D

    2010-01-01

    A multichannel optical coherence tomography (multi-beam OCT) system and an in vivo endoscopic imaging probe were developed using a swept-source OCT system. The distal optics were micro-machined to produce a high numerical aperture, multi-focus fibre optic array. This combination resulted in a transverse design resolution of <10 μm full width half maximum (FWHM) throughout the entire imaging range, while also increasing the signal intensity within the focus of the individual channels. The system was used in a pre-clinical rabbit study to acquire in vivo structural images of the colon and ex vivo images of the oesophagus and trachea. A good correlation between the structural multi-beam OCT images and H and E histology was achieved, demonstrating the feasibility of this high-resolution system and its potential for in vivo human endoscopic imaging.

  5. Imaging of dental implant osseointegration using optical coherent tomography

    Science.gov (United States)

    Ionita, I.; Reisen, P.

    2009-02-01

    Investigation of initial implant stability with different dental implant designs is an important task to obtain good quality dental implants. Failure of a dental implant is often related to failure to osseointegrate correctly. Optical Coherent Tomography is a competitive non-invasive method of osseointegration investigation. FD-OCT with Swept Source was used to obtain 3-D image of the peri-implant tissue (soft and hard) in the case of mandible fixed screw. 1350 nm centered laser source give better images than 850 nm laser source for hard tissue imaging. Present work suggests that Optical Coherent Tomography is a proper technique to obtain the image of the contact tissue-metal screw. OCT images are useful to evaluate optical properties of bone tissues.

  6. Optical coherence tomography angiography of optic nerve head and parafovea in multiple sclerosis.

    Science.gov (United States)

    Wang, Xiaogang; Jia, Yali; Spain, Rebecca; Potsaid, Benjamin; Liu, Jonathan J; Baumann, Bernhard; Hornegger, Joachim; Fujimoto, James G; Wu, Qiang; Huang, David

    2014-10-01

    To investigate swept-source optical coherence tomography (OCT) angiography in the optic nerve head (ONH) and parafoveal regions in patients with multiple sclerosis (MS). Fifty-two MS eyes and 21 healthy control (HC) eyes were included. There were two MS subgroups: 38 MS eyes without an optic neuritis (ON) history (MS -ON), and 14 MS eyes with an ON history (MS +ON). The OCT images were captured by high-speed 1050 nm swept-source OCT. The ONH flow index (FI) and parafoveal FI were quantified from OCT angiograms. The mean ONH FI was 0.160 ± 0.010 for the HC group, 0.156 ± 0.017 for the MS-ON group, and 0.140 ± 0.020 for the MS+ON group. The ONH FI of the MS+ON group was reduced by 12.5% compared to HC eyes (p=0.004). A higher percentage of MS+ON eyes had abnormal ONH FI compared to HC patients (43% vs 5%, p=0.01). Mean parafoveal FIs were 0.126 ± 0.007, 0.127 ± 0.010, and 0.129 ± 0.005 for the HC, MS-ON, and MS +ON groups, respectively, and did not differ significantly among them. The coefficient of variation (CV) of intravisit repeatability and intervisit reproducibility were 1.03% and 4.53% for ONH FI, and 1.65% and 3.55% for parafoveal FI. Based on OCT angiography, the FI measurement is feasible, highly repeatable and reproducible, and it is suitable for clinical measurement of ONH and parafoveal perfusion. The ONH FI may be useful in detecting damage from ON and quantifying its severity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  8. Development and Application of Multifunctional Optical Coherence Tomography

    Science.gov (United States)

    Zhi, Zhongwei

    Microcirculation refers to the functions of capillaries and the neighboring lymphatic vessels. It plays a vital role in the pathophysiology of disorders in many clinical areas including cardiology, dermatology, neurology and ophthalmology, and so forth. It is crucial to develop imaging technologies that can provide both qualitative and quantitative information as to how microcirculation responds to certain injury and/or disease, and its treatment. Optical coherence tomography (OCT) is a non-invasive optical imaging technique for high-resolution cross-sectional imaging of specimens, with many applications in clinical medicine. Current state-of-the-art OCT systems operate in the Fourier domain, using either a broadband light source with a spectrometer, known as spectral domain OCT (SDOCT), or a rapidly tunable laser, known as swept source OCT (SSOCT). The current Fourier domain OCT systems have dramatically improvement in sensitivity, resolution and speed compared to time domain OCT. In addition to the improvement in the OCT system hardware, different methods for functional measurements of tissue beds have been developed and demonstrated. This includes but not limited to, i) Phase-resolved Doppler OCT for quantifying the blood flow, ii) OCT angiography for visualization of microvasculature, iii) Polarization sensitive OCT for measuring the intrinsic optical property/ birefringence of tissue, iv) spectroscopic OCT for measuring blood oxygenation, etc. Functional OCT can provide important clinical information that is not available in the typical intensity based structural OCT images. Among these functional OCT modalities, Doppler OCT and OCT angiography attract great interests as they show high capability for in vivo study of microvascular pathology. By analyzing the Doppler effect of a flowing particle on light frequency, Doppler OCT allows the quantification of the blood flow speed and blood flow rate. The most popular approach for Doppler OCT is achieved through

  9. Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s.

    Science.gov (United States)

    Huber, Robert; Adler, Desmond C; Fujimoto, James G

    2006-10-15

    We describe buffered Fourier domain mode locking (FDML), a technique for tailoring the output and multiplying the sweep rate of FDML lasers. Buffered FDML can be used to create unidirectional wavelength sweeps from the normal bidirectional sweeps in an FDML laser without sacrificing sweep rate. We also investigate the role of the laser source in dynamic range versus sensitivity performance in optical coherence tomography (OCT) imaging. Unidirectional sweep rates of 370 kHz over a 100 nm range at a center wavelength of 1300 nm are achieved. High-speed, swept-source OCT is demonstrated at record speeds of up to 370,000 axial scans per second.

  10. Gabor fusion master slave optical coherence tomography.

    Science.gov (United States)

    Cernat, Ramona; Bradu, Adrian; Israelsen, Niels Møller; Bang, Ole; Rivet, Sylvain; Keane, Pearse A; Heath, David-Garway; Rajendram, Ranjan; Podoleanu, Adrian

    2017-02-01

    This paper describes the application of the Gabor filtering protocol to a Master/Slave (MS) swept source optical coherence tomography (SS)-OCT system at 1300 nm. The MS-OCT system delivers information from selected depths, a property that allows operation similar to that of a time domain OCT system, where dynamic focusing is possible. The Gabor filtering processing following collection of multiple data from different focus positions is different from that utilized by a conventional swept source OCT system using a Fast Fourier transform (FFT) to produce an A-scan. Instead of selecting the bright parts of A-scans for each focus position, to be placed in a final B-scan image (or in a final volume), and discarding the rest, the MS principle can be employed to advantageously deliver signal from the depths within each focus range only. The MS procedure is illustrated on creating volumes of data of constant transversal resolution from a cucumber and from an insect by repeating data acquisition for 4 different focus positions. In addition, advantage is taken from the tolerance to dispersion of the MS principle that allows automatic compensation for dispersion created by layers above the object of interest. By combining the two techniques, Gabor filtering and Master/Slave, a powerful imaging instrument is demonstrated. The master/slave technique allows simultaneous display of three categories of images in one frame: multiple depth en-face OCT images, two cross-sectional OCT images and a confocal like image obtained by averaging the en-face ones. We also demonstrate the superiority of MS-OCT over its FFT based counterpart when used with a Gabor filtering OCT instrument in terms of the speed of assembling the fused volume. For our case, we show that when more than 4 focus positions are required to produce the final volume, MS is faster than the conventional FFT based procedure.

  11. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  12. Remineralization of Enamel Caries Can Decrease Optical Reflectivity

    OpenAIRE

    Jones, R.S.; Fried, D.

    2006-01-01

    The remineralization of enamel caries can lead to distinct optical changes within a lesion. We hypothesized that the restoration of mineral volume would result in a measurable decrease in the depth-resolved reflectivity of polarized light from the lesion. To test this hypothesis, we measured optical changes in artificial caries undergoing remineralization as a function of depth, using Polarization-sensitive Optical Coherence Tomography (PS-OCT). Lesions were imaged non-destructively before an...

  13. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  14. Simultaneous in situ measurements of properties of particulates in rf silane plasmas using a polarization-sensitive laser-light-scattering method

    Science.gov (United States)

    Shiratani, Masaharu; Kawasaki, Hiroharu; Fukuzawa, Tsuyoshi; Yoshioka, Takashi; Ueda, Yoshio; Singh, Sanjay; Watanabe, Yukio

    1996-01-01

    A polarization-sensitive laser-light-scattering method is developed for simultaneous in situ measurements of properties (size, size dispersion, density, and refractive index) of particulates formed in processing plasmas. The developed system is applied to observe the growth processes of particulates in a range of their size larger than about 10 nm in rf silane plasmas. A size, a size dispersion (logarithm of a standard deviation of size), a density, and a refractive index of particulates in the plasmas are found to be 10-200 nm, about 0.1, 107-109 cm-3 and about 3-5i, respectively. The former three of such values agree fairly well with ones deduced from scanning electron microscopic (SEM) observation. These particulates grow through three phases of nucleation and initial growth, rapid growth, and growth saturation. Coexistence of two size groups of particulates with narrow size dispersions during and after the rapid growth phase verified by the SEM observation may be explained by a model taking into account coagulation between oppositely charged particulates.

  15. Sapphire ball lens-based fiber probe for common-path optical coherence tomography and its applications in corneal and retinal imaging.

    Science.gov (United States)

    Zhao, Mingtao; Huang, Yong; Kang, Jin U

    2012-12-01

    We describe a common-path swept source optical coherence tomography fiber probe design using a sapphire ball lens for cross-sectional imaging and sensing for retina vitrectomy surgery. The high refractive index (n=1.75) of the sapphire ball lens improves the focusing power and enables the probe to operate in the intraocular space. The highly precise spherical shape of the sapphire lens also reduces astigmatism and coma compared to fused nonspherical ball lenses. A theoretical sensitivity model for common-path optical coherence tomography (CP-OCT) was developed to assess its optimal performance based on an unbalanced photodetector configuration. Two probe designs-with working distances 415 and 1221 μm and lateral resolution 11 and 18 μm-were implemented with sensitivity up to 88 dB, which is significantly higher than previously reported CP-OCT probes. We assessed the performances of the fiber probes by cross-sectional imaging a bovine cornea and retina in air and in vitreous gel with a 1310 nm swept source OCT system. To the best of our knowledge, this is the first demonstration of sapphire ball lens-based CP-OCT probes directly inserted into the vitreous gel of a bovine eyeball for ocular imaging with a sensitivity approaching the theoretical limitation of CP-OCT.

  16. MEMS optical tunable filter based on free-standing subwavelength silicon layers

    Science.gov (United States)

    Omran, Haitham; Sabry, Yasser M.; Sadek, Mohamed; Hassan, Khaled; Shalaby, Mohamed Y.; Khalil, Diaa

    2014-03-01

    We report a MEMS optical tunable filter based on high-aspect-ratio etching of sub-wavelength silicon layers on a silicon- on-insulator wafer. The reported filter has measured free-spectral and filter-tuning ranges of approximately 100 nm and a finesse of about 20 around a wavelength of 1550 nm, enabled by the use of 1000 nm-thick silicon layers and a balanced tilt-free motion using a lithographically-aligned electrostatic actuator. The average insertion loss of the filter is about 12 dB with a superior wavelength-dependent loss of about 1.5 dB. The filter has an out-of-band to in-band wavelength rejection ratio that is better than 20 dB. The reported filter experimental characteristics and its integrability are suitable for the production of integrated swept sources for optical coherence tomography application and miniaturized spectrometers.

  17. Wide tuning range wavelength-swept laser with a single SOA at 1020 nm for ultrahigh resolution Fourier-domain optical coherence tomography.

    Science.gov (United States)

    Lee, Sang-Won; Song, Hyun-Woo; Jung, Moon-Youn; Kim, Seung-Hwan

    2011-10-24

    In this study, we demonstrated a wide tuning range wavelength-swept laser with a single semiconductor optical amplifier (SOA) at 1020 nm for ultrahigh resolution, Fourier-domain optical coherence tomography (UHR, FD-OCT). The wavelength-swept laser was constructed with an external line-cavity based on a Littman configuration. An optical wavelength selection filter consisted of a grating, a telescope, and a polygon scanner. Before constructing the optical wavelength selection filter, we observed that the optical power, the spectrum bandwidth, and the center wavelength of the SOA were affected by the temperature of the thermoelectric (TE) cooler in the SOA mount as well as the applied current. Therefore, to obtain a wide wavelength tuning range, we adjusted the temperature of the TE cooler in the SOA mount. When the temperature in the TE cooler was 9 °C, our swept source had a tuning range of 142 nm and a full-width at half-maximum (FWHM) of 121.5 nm at 18 kHz. The measured instantaneous spectral bandwidth (δλ) is 0.085 nm, which was measured by an optical spectrum analyzer with a resolution bandwidth of 0.06 nm. This value corresponds to an imaging depth of 3.1 mm in air. Additionally, the averaged optical power of our swept source was 8.2 mW. In UHR, FD/SS-OCT using our swept laser, the measured axial resolution was 4.0 μm in air corresponding to 2.9 μm in tissue (n = 1.35). The sensitivity was measured to be 93.1 dB at a depth of 100 μm. Finally, we obtained retinal images (macular and optic disk) and a corneal image. © 2011 Optical Society of America

  18. An All-Fiber-Optic Combined System of Noncontact Photoacoustic Tomography and Optical Coherence Tomography.

    Science.gov (United States)

    Eom, Jonghyun; Shin, Jun Geun; Park, Soongho; Rim, Sunghwan; Lee, Byeong Ha

    2016-05-20

    We propose an all-fiber-based dual-modal imaging system that combines noncontact photoacoustic tomography (PAT) and optical coherence tomography (OCT). The PAT remotely measures photoacoustic (PA) signals with a 1550-nm laser on the surface of a sample by utilizing a fiber interferometer as an ultrasound detector. The fiber-based OCT, employing a swept-source laser centered at 1310 nm, shares the sample arm of the PAT system. The fiber-optic probe for the combined system was homemade with a lensed single-mode fiber (SMF) and a large-core multimode fiber (MMF). The compact and robust common probe is capable of obtaining both the PA and the OCT signals at the same position without any physical contact. Additionally, the MMF of the probe delivers the short pulses of a Nd:YAG laser to efficiently excite the PA signals. We experimentally demonstrate the feasibility of the proposed dual-modal system with a phantom made of a fishing line and a black polyethylene terephthalate fiber in a tissue mimicking solution. The all-fiber-optic system, capable of providing complementary information about absorption and scattering, has a promising potential in minimally invasive and endoscopic imaging.

  19. Microscope-integrated optical coherence tomography for image-aided positioning of glaucoma surgery.

    Science.gov (United States)

    Li, Xiqi; Wei, Ling; Dong, Xuechuan; Huang, Ping; Zhang, Chun; He, Yi; Shi, Guohua; Zhang, Yudong

    2015-07-01

    Most glaucoma surgeries involve creating new aqueous outflow pathways with the use of a small surgical instrument. This article reported a microscope-integrated, real-time, high-speed, swept-source optical coherence tomography system (SS-OCT) with a 1310-nm light source for glaucoma surgery. A special mechanism was designed to produce an adjustable system suitable for use in surgery. A two-graphic processing unit architecture was used to speed up the data processing and real-time volumetric rendering. The position of the surgical instrument can be monitored and measured using the microscope and a grid-inserted image of the SS-OCT. Finally, experiments were simulated to assess the effectiveness of this integrated system. Experimental results show that this system is a suitable positioning tool for glaucoma surgery.

  20. Phase sensitive optical coherence microscopy for photothermal imaging of gold nanorods

    Science.gov (United States)

    Hu, Yong; Podoleanu, Adrian G.; Dobre, George

    2018-03-01

    We describe a swept source based phase sensitive optical coherence microscopy (OCM) system for photothermal imaging of gold nanorods (GNR). The phase sensitive OCM system employed in the study has a displacement sensitivity of 0.17 nm to vibrations at single frequencies below 250 Hz. We demonstrate the generation of phase maps and confocal phase images. By displaying the difference between successive confocal phase images, we perform the confocal photothermal imaging of accumulated GNRs behind a glass coverslip and behind the scattering media separately. Compared with two-photon luminescence (TPL) detection techniques reported in literature, the technique in this study has the advantage of a simplified experimental setup and provides a more efficient method for imaging the aggregation of GNR. However, the repeatability performance of this technique suffers due to jitter noise from the swept laser source.

  1. Ball lens based lensed patch cord probes for optical coherence tomography in the field of dentistry

    Science.gov (United States)

    Eom, J. B.; Kim, Y.; Lee, S. J.; Min, E. J.; Park, S. J.; Lee, B. H.

    2012-10-01

    A lensed patch cord probe has been made with a ball lens packaged in a metal cylinder. By simply placing a ball lens directly in front of a fiber patch cord, a compact and potentially disposable sampling probe for optical coherence tomography (OCT) could be implemented. To achieve a sufficiently long working distance and a good transverse resolution simultaneously, the proper ball lens diameter and the distance between the ball lens and the fiber patch cord were investigated. Experimentally, a working distance of up to 5.2 mm, 3 dB bandwidth of 2 mm, and transverse resolution of 16 μm were achieved. With the patch cord probe, a common path swept source OCT system was implemented and used to demonstrate the feasibility as the dedicated probe for dentistry.

  2. Utilizing optical coherence tomography for CAD/CAM of indirect dental restorations

    Science.gov (United States)

    Chityala, Ravishankar; Vidal, Carola; Jones, Robert

    Optical Coherence Tomography (OCT) has seen broad application in dentistry including early carious lesion detection and imaging defects in resin composite restorations. This study investigates expanding the clinical usefulness by investigating methods to use OCT for obtaining three-dimensional (3D) digital impressions, which can be integrated to CAD/CAM manufacturing of indirect restorations. 3D surface topography `before' and `after' a cavity preparation was acquired by an intraoral cross polarization swept source OCT (CP-OCT) system with a Micro-Electro-Mechanical System (MEMS) scanning mirror. Image registration and segmentation methods were used to digitally construct a replacement restoration that modeled the original surface morphology of a hydroxyapatite sample. After high resolution additive manufacturing (e.g. polymer 3D printing) of the replacement restoration, micro-CT imaging was performed to examine the marginal adaptation. This study establishes the protocol for further investigation of integrating OCT with CAD/CAM of indirect dental restorations.

  3. Polarimetry noise in fiber-based optical coherence tomography instrumentation

    Science.gov (United States)

    Zhang, Ellen Ziyi; Vakoc, Benjamin J.

    2011-01-01

    High noise levels in fiber-based polarization-sensitive optical coherence tomography (PS-OCT) have broadly limited its clinical utility. In this study we investigate contribution of polarization mode dispersion (PMD) to the polarimetry noise. We develop numerical models of the PS-OCT system including PMD and validate these models with empirical data. Using these models, we provide a framework for predicting noise levels, for processing signals to reduce noise, and for designing an optimized system. PMID:21935044

  4. Optical Inspection and Morphological Analysis of Diospyros kaki Plant Leaves for the Detection of Circular Leaf Spot Disease

    Directory of Open Access Journals (Sweden)

    Ruchire Eranga Wijesinghe

    2016-08-01

    Full Text Available The feasibility of using the bio-photonic imaging technique to assess symptoms of circular leaf spot (CLS disease in Diospyros kaki (persimmon leaf samples was investigated. Leaf samples were selected from persimmon plantations and were categorized into three groups: healthy leaf samples, infected leaf samples, and healthy-looking leaf samples from infected trees. Visually non-identifiable reduction of the palisade parenchyma cell layer thickness is the main initial symptom, which occurs at the initial stage of the disease. Therefore, we established a non-destructive bio-photonic inspection method using a 1310 nm swept source optical coherence tomography (SS-OCT system. These results confirm that this method is able to identify morphological differences between healthy leaves from infected trees and leaves from healthy and infected trees. In addition, this method has the potential to generate significant cost savings and good control of CLS disease in persimmon fields.

  5. Assessing ex vivo dental biofilms and in vivo composite restorations using cross-polarization optical coherence tomography

    Science.gov (United States)

    Jones, R.; Aparicio, C.; Chityala, R.; Chen, R.; Fok, A.; Rudney, J.

    2012-01-01

    A cross-polarization 1310-nm optical coherence tomography system (CP-OCT), using a beam splitter based design, was used to assess ex vivo growth of complex multi-species dental biofilms. These biofilm microcosms were derived from plaque samples along the interface of composite or amalgam restoration in children with a history of early childhood caries. This paper presents a method of measuring the mean biofilm height of mature biofilms using CP-OCT. For our in vivo application, the novel swept source based CP-OCT intraoral probe (Santec Co. Komaki, Japan) dimensions and system image acquisition speed (20 image frames/second) allowed imaging pediatric subjects as young as 4 years old. The subsurface enamel under the interface of composite resin restorations of pediatric subjects were imaged using CP-OCT. Cavitated secondary caries is clearly evident from sound resin composite restorations.

  6. Advances of optical coherence tomography in myopia and pathologic myopia.

    Science.gov (United States)

    Ng, D S C; Cheung, C Y L; Luk, F O; Mohamed, S; Brelen, M E; Yam, J C S; Tsang, C W; Lai, T Y Y

    2016-07-01

    The natural course of high-axial myopia is variable and the development of pathologic myopia is not fully understood. Advancements in optical coherence tomography (OCT) technology have revealed peculiar intraocular structures in highly myopic eyes and unprecedented pathologies that cause visual impairment. New OCT findings include posterior precortical vitreous pocket and precursor stages of posterior vitreous detachment; peripapillary intrachoroidal cavitation; morphological patterns of scleral inner curvature and dome-shaped macula. Swept source OCT is capable of imaging deeper layers in the posterior pole for investigation of optic nerve pits, stretched and thinned lamina cribrosa, elongated dural attachment at posterior scleral canal, and enlargement of retrobulbar subarachnoid spaces. This has therefore enabled further evaluation of various visual field defects in high myopia and the pathogenesis of glaucomatous optic neuropathy. OCT has many potential clinical uses in managing visual impairing conditions in pathologic myopia. Understanding how retinal nerve fibers are redistributed in axial elongation will allow the development of auto-segmentation software for diagnosis and monitoring progression of glaucoma. OCT is indispensable in the diagnosis of various conditions associated with myopic traction maculopathy and monitoring of post-surgical outcomes. In addition, OCT is commonly used in the multimodal imaging assessment of myopic choroidal neovascularization. Biometry and topography of the retinal layers and choroid will soon be validated for the classification of myopic maculopathy for utilization in epidemiological studies as well as clinical trials.

  7. Miniature endoscopic optical coherence tomography for calculus detection.

    Science.gov (United States)

    Kao, Meng-Chun; Lin, Chun-Li; Kung, Che-Yen; Huang, Yi-Fung; Kuo, Wen-Chuan

    2015-08-20

    The effective treatment of periodontitis involves the detection and removal of subgingival dental calculus. However, subgingival calculus is more difficult to detect than supragingival calculus because it is firmly attached to root surfaces within periodontal pockets. To achieve a smooth root surface, clinicians often remove excessive amounts of root structure because of decreased visibility. In addition, enamel pearl, a rare type of ectopic enamel formation on the root surface, can easily be confused with dental calculus in the subgingival environment. In this study, we developed a fiber-probe swept-source optical coherence tomography (SSOCT) technique and combined it with the quantitative measurement of an optical parameter [standard deviation (SD) of the optical coherence tomography (OCT) intensity] to differentiate subgingival calculus from sound enamel, including enamel pearl. Two-dimensional circumferential images were constructed by rotating the miniprobe (0.9 mm diameter) while acquiring image lines, and the adjacent lines in each rotation were stacked to generate a three-dimensional volume. In OCT images, compared to sound enamel and enamel pearls, dental calculus showed significant differences (Pcalculus.

  8. Optical detection dental disease using polarized light

    Science.gov (United States)

    Everett, Matthew J.; Colston, Jr., Billy W.; Sathyam, Ujwal S.; Da Silva, Luiz B.; Fried, Daniel

    2003-01-01

    A polarization sensitive optical imaging system is used to detect changes in polarization in dental tissues to aid the diagnosis of dental disease such as caries. The degree of depolarization is measured by illuminating the dental tissue with polarized light and measuring the polarization state of the backscattered light. The polarization state of this reflected light is analyzed using optical polarimetric imaging techniques. A hand-held fiber optic dental probe is used in vivo to direct the incident beam to the dental tissue and collect the reflected light. To provide depth-resolved characterization of the dental tissue, the polarization diagnostics may be incorporated into optical coherence domain reflectometry and optical coherence tomography (OCDR/OCT) systems, which enables identification of subsurface depolarization sites associated with demineralization of enamel or bone.

  9. (Full field) optical coherence tomography and applications

    Science.gov (United States)

    Buchroithner, Boris; Hannesschläger, Günther; Leiss-Holzinger, Elisabeth; Prylepa, Andrii; Heise, Bettina

    2018-03-01

    This paper illustrates specific features and use of optical coherence tomography (OCT) in the raster-scanning and in comparison in the full field version of this imaging technique. Cases for nondestructive testing are discussed alongside other application schemes. In particular monitoring time-dependent processes and probing of birefringent specimens are considered here. In the context of polymer testing birefringence mapping may often provide information about internal strain and stress states. Recent results obtained with conventional raster-scanning OCT systems, with (dual and single-shot) full field OCT configurations, and with polarization-sensitive versions of (full field) OCT are presented here.

  10. Design and performance evaluation of 1-by-64 multimode interference power splitter for optical communications

    DEFF Research Database (Denmark)

    Rasmussen, Thomas; Rasmussen, Jesper Kiel; Povlsen, Jørn Hedegaard

    1995-01-01

    A 1-by-64 multimode interference power splitter in SiO2 has been designed for use in fiber-optics communication systems. The splitter exhibits a minimum loss of 0.5 db and a uniformity of 1.7 dB at a wavelength of 1.55 μm. The polarization sensitivity is below 0.14 dB, the reflection level below ...

  11. From Dark to Light to Fluorescence Resonance Energy Transfer (FRET): Polarity-Sensitive Aggregation-Induced Emission (AIE)-Active Tetraphenylethene-Fused BODIPY Dyes with a Very Large Pseudo-Stokes Shift.

    Science.gov (United States)

    Şen, Esra; Meral, Kadem; Atılgan, Serdar

    2016-01-11

    The work presented herein is devoted to the fabrication of large Stokes shift dyes in both organic and aqueous media by combining dark resonance energy transfer (DRET) and fluorescence resonance energy transfer (FRET) in one donor-acceptor system. In this respect, a series of donor-acceptor architectures of 4,4-difluoro-4-bora-3a,4a-diaza-s-indacene (BODIPY) dyes substituted by one, two, or three tetraphenylethene (TPE) luminogens were designed and synthesised. The photophysical properties of these three chromophore systems were studied to provide insight into the nature of donor-acceptor interactions in both THF and aqueous media. Because the generation of emissive TPE donor(s) is strongly polarity dependent, due to its aggregation-induced emission (AIE) feature, one might expect the formation of appreciable fluorescence emission intensity with a very large pseudo-Stokes shift in aqueous media when considering FRET process. Interestingly, similar results were also recorded in THF for the chromophore systems, although the TPE fragment(s) of the dyes are non-emissive. The explanation for this photophysical behaviour lies in the DRET. This is the first report on combining two energy-transfer processes, namely, FRET and DRET, in one polarity-sensitive donor-acceptor pair system. The accuracy of the dark-emissive donor property of the TPE luminogen is also presented for the first time as a new feature for AIE phenomena. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Data-based online nonlinear extremum-seeker for wavefront sensorless adaptive optics OCT (Conference Presentation)

    Science.gov (United States)

    Jian, Yifan; Verstraete, Hans R. G. W.; Heisler, Morgan; Ju, Myeong Jin; Wahl, Daniel J.; Bliek, Laurens; Kalkman, Jeroen; Bonora, Stefano; Verhaegen, Michel; Sarunic, Marinko V.

    2017-02-01

    Adaptive optics has been successfully applied to cellular resolution imaging of the retina, enabling visualization of the characteristic mosaic patterns of the outer retina. Wavefront sensorless adaptive optics (WSAO) is a novel technique that facilitates high resolution ophthalmic imaging; it replaces the Hartmann-Shack Wavefront Sensor with an image-driven optimization algorithm and mitigates some the challenges encountered with sensor-based designs. However, WSAO generally requires longer time to perform aberrations correction than the conventional closed-loop adaptive optics. When used for in vivo retinal imaging applications, motion artifacts during the WSAO optimization process will affect the quality of the aberration correction. A faster converging optimization scheme needs to be developed to account for rapid temporal variation of the wavefront and continuously apply corrections. In this project, we investigate the Databased Online Nonlinear Extremum-seeker (DONE), a novel non-linear multivariate optimization algorithm in combination with in vivo human WSAO OCT imaging. We also report both hardware and software updates of our compact lens based WSAO 1060nm swept source OCT human retinal imaging system, including real time retinal layer segmentation and tracking (ILM and RPE), hysteresis correction for the multi-actuator adaptive lens, precise synchronization control for the 200kHz laser source, and a zoom lens unit for rapid switching of the field of view. Cross sectional images of the retinal layers and en face images of the cone photoreceptor mosaic acquired in vivo from research volunteers before and after WSAO optimization are presented.

  13. Electrostatic forward-viewing scanning probe for Doppler optical coherence tomography using a dissipative polymer catheter.

    Science.gov (United States)

    Munce, Nigel R; Mariampillai, Adrian; Standish, Beau A; Pop, Mihaela; Anderson, Kevan J; Liu, George Y; Luk, Tim; Courtney, Brian K; Wright, Graham A; Vitkin, I Alex; Yang, Victor X D

    2008-04-01

    A novel flexible scanning optical probe is constructed with a finely etched optical fiber strung through a platinum coil in the lumen of a dissipative polymer. The packaged probe is 2.2 mm in diameter with a rigid length of 6mm when using a ball lens or 12 mm when scanning the fiber proximal to a gradient-index (GRIN) lens. Driven by constant high voltage (1-3 kV) at low current (probe oscillates to provide wide forward-viewing angle (13 degrees and 33 degrees with ball and GRIN lens designs, respectively) and high-frame-rate (10-140 fps) operation. Motion of the probe tip is observed with a high-speed camera and compared with theory. Optical coherence tomography (OCT) imaging with the probe is demonstrated with a wavelength-swept source laser. Images of an IR card as well as in vivo Doppler OCT images of a tadpole heart are presented. This optomechanical design offers a simple, inexpensive method to obtain a high-frame-rate forward-viewing scanning probe.

  14. Optical sensing method to analyze germination rate of Capsicum annum seeds treated with growth-promoting chemical compounds using optical coherence tomography

    Science.gov (United States)

    Wijesinghe, Ruchire Eranga; Lee, Seung-Yeol; Kim, Pilun; Jung, Hee-Young; Jeon, Mansik; Kim, Jeehyun

    2017-09-01

    Seed germination rate differs based on chemical treatments, and nondestructive measurements of germination rate have become an essential requirement in the field of agriculture. Seed scientists and other biologists are interested in optical sensing technologies-based biological discoveries due to nondestructive detection capability. Optical coherence tomography (OCT) has recently emerged as a powerful method for biological and plant material discoveries. We report an extended application of OCT by monitoring the germination rate acceleration of chemically primed seeds. To validate the versatility of the method, Capsicum annum seeds were primed using three chemical compounds: sterile distilled water (SDW), butandiol, and 1-hexadecene. Monitoring was performed using a 1310-nm swept source OCT system. The results confirmed more rapid morphological variations in the seeds treated with 1-hexadecene medium than the seeds treated with SDW and butandiol within 8 consecutive days. In addition, fresh weight measurements (gold standard) of seeds were monitored for 15 days, and the obtained results were correlated with the OCT results. Thus, such a method can be used in various agricultural fields, and OCT shows potential as a rigorous sensing method for selecting the optimal plant growth-promoting chemical compounds rapidly, when compared with the gold standard methods.

  15. MEMS-based handheld fourier domain Doppler optical coherence tomography for intraoperative microvascular anastomosis imaging.

    Directory of Open Access Journals (Sweden)

    Yong Huang

    Full Text Available To demonstrate the feasibility of a miniature handheld optical coherence tomography (OCT imager for real time intraoperative vascular patency evaluation in the setting of super-microsurgical vessel anastomosis.A novel handheld imager Fourier domain Doppler optical coherence tomography based on a 1.3-µm central wavelength swept source for extravascular imaging was developed. The imager was minimized through the adoption of a 2.4-mm diameter microelectromechanical systems (MEMS scanning mirror, additionally a 12.7-mm diameter lens system was designed and combined with the MEMS mirror to achieve a small form factor that optimize functionality as a handheld extravascular OCT imager. To evaluate in-vivo applicability, super-microsurgical vessel anastomosis was performed in a mouse femoral vessel cut and repair model employing conventional interrupted suture technique as well as a novel non-suture cuff technique. Vascular anastomosis patency after clinically successful repair was evaluated using the novel handheld OCT imager.With an adjustable lateral image field of view up to 1.5 mm by 1.5 mm, high-resolution simultaneous structural and flow imaging of the blood vessels were successfully acquired for BALB/C mouse after orthotopic hind limb transplantation using a non-suture cuff technique and BALB/C mouse after femoral artery anastomosis using a suture technique. We experimentally quantify the axial and lateral resolution of the OCT to be 12.6 µm in air and 17.5 µm respectively. The OCT has a sensitivity of 84 dB and sensitivity roll-off of 5.7 dB/mm over an imaging range of 5 mm. Imaging with a frame rate of 36 Hz for an image size of 1000(lateral×512(axial pixels using a 50,000 A-lines per second swept source was achieved. Quantitative vessel lumen patency, lumen narrowing and thrombosis analysis were performed based on acquired structure and Doppler images.A miniature handheld OCT imager that can be used for intraoperative evaluation of

  16. Ultrahigh-speed optical coherence tomography for three-dimensional and en face imaging of the retina and optic nerve head.

    Science.gov (United States)

    Srinivasan, Vivek J; Adler, Desmond C; Chen, Yueli; Gorczynska, Iwona; Huber, Robert; Duker, Jay S; Schuman, Joel S; Fujimoto, James G

    2008-11-01

    To demonstrate ultrahigh-speed optical coherence tomography (OCT) imaging of the retina and optic nerve head at 249,000 axial scans per second and a wavelength of 1060 nm. To investigate methods for visualization of the retina, choroid, and optic nerve using high-density sampling enabled by improved imaging speed. A swept-source OCT retinal imaging system operating at a speed of 249,000 axial scans per second was developed. Imaging of the retina, choroid, and optic nerve were performed. Display methods such as speckle reduction, slicing along arbitrary planes, en face visualization of reflectance from specific retinal layers, and image compounding were investigated. High-definition and three-dimensional (3D) imaging of the normal retina and optic nerve head were performed. Increased light penetration at 1060 nm enabled improved visualization of the choroid, lamina cribrosa, and sclera. OCT fundus images and 3D visualizations were generated with higher pixel density and less motion artifacts than standard spectral/Fourier domain OCT. En face images enabled visualization of the porous structure of the lamina cribrosa, nerve fiber layer, choroid, photoreceptors, RPE, and capillaries of the inner retina. Ultrahigh-speed OCT imaging of the retina and optic nerve head at 249,000 axial scans per second is possible. The improvement of approximately 5 to 10x in imaging speed over commercial spectral/Fourier domain OCT technology enables higher density raster scan protocols and improved performance of en face visualization methods. The combination of the longer wavelength and ultrahigh imaging speed enables excellent visualization of the choroid, sclera, and lamina cribrosa.

  17. Remineralization of enamel caries can decrease optical reflectivity.

    Science.gov (United States)

    Jones, R S; Fried, D

    2006-09-01

    The remineralization of enamel caries can lead to distinct optical changes within a lesion. We hypothesized that the restoration of mineral volume would result in a measurable decrease in the depth-resolved reflectivity of polarized light from the lesion. To test this hypothesis, we measured optical changes in artificial caries undergoing remineralization as a function of depth, using Polarization-sensitive Optical Coherence Tomography (PS-OCT). Lesions were imaged non-destructively before and after exposure to a remineralization regimen. After imaging, microradiographs of histological thin sections indicated that the significant reflectivity reduction measured by PS-OCT accurately represented the increase in mineral content within a larger repaired surface zone. Mineral volume changes arising from remineralization can be measured on the basis of the optical reflectivity of the lesion.

  18. Is the Optic Nerve Head Structure Impacted by a Diagnostic Lumbar Puncture in Humans?

    Science.gov (United States)

    Poli, Muriel; Denis, Philippe; Sellem, Eric; Aho-Glélé, Ludwig-Serge; Bron, Alain M

    2017-11-01

    The purpose of this study is to assess in vivo whether diagnostic lumbar puncture (LP) is followed by optic nerve head (ONH) and parapapillary anatomic changes in normal human eyes. Prospective, single-center, observational case series. ONH structures (prelaminar tissue surface, anterior surface of the lamina cribrosa, central retinal vessels) and parapapillary structures (internal limiting membrane, posterior surfaces of retinal nerve fiber layer and Bruch membrane/retinal pigment epithelium complex, Bruch membrane opening, posterior surface of the choroid) were quantitatively evaluated by means of swept-source optical coherence tomography (Triton Ver.10.05, Topcon, Tokyo, Japan) before and after LP (5, 60, and 360 min). Each of these structures was manually delineated for measurement before being superimposed to detect any displacement, using peripheral margins of parapapillary structures as a reference plane. A total of 16 eyes of 8 nonglaucomatous patients were evaluated. The CSF volume was median (IQR), 1.65 mL (1.16 to 2.00) and none of the ONH structures showed any anatomic changes at any time point after LP. According to the design of this study, diagnostic LP is a safe procedure regarding deep ONH structures in nonglaucomatous subjects.

  19. Photothermal detection of gold nanoparticles using phase-sensitive optical coherence tomography.

    Science.gov (United States)

    Adler, Desmond C; Huang, Shu-Wei; Huber, Robert; Fujimoto, James G

    2008-03-31

    The detection of a gold nanoparticle contrast agent is demonstrated using a photothermal modulation technique and phase sensitive optical coherence tomography (OCT). A focused beam from a laser diode at 808 nm is modulated at frequencies of 500 Hz-60 kHz while irradiating a solution containing nanoshells. Because the nanoshells are designed to have a high absorption coefficient at 808 nm, the laser beam induces small-scale localized temperature oscillations at the modulation frequency. These temperature oscillations result in optical path length changes that are detected by a phase-sensitive, swept source OCT system. The OCT system uses a double-buffered Fourier domain mode locked (FDML) laser operating at a center wavelength of 1315 nm and a sweep rate of 240 kHz. High contrast is observed between phantoms containing nanoshells and phantoms without nanoshells. This technique represents a new method for detecting gold nanoparticle contrast agents with excellent signal-to-noise performance at high speeds using OCT.

  20. Real time en face Fourier-domain optical coherence tomography with direct hardware frequency demodulation.

    Science.gov (United States)

    Biedermann, Benjamin R; Wieser, Wolfgang; Eigenwillig, Christoph M; Palte, Gesa; Adler, Desmond C; Srinivasan, Vivek J; Fujimoto, James G; Huber, Robert

    2008-11-01

    We demonstrate en face swept source optical coherence tomography (ss-OCT) without requiring a Fourier transformation step. The electronic optical coherence tomography (OCT) interference signal from a k-space linear Fourier domain mode-locked laser is mixed with an adjustable local oscillator, yielding the analytic reflectance signal from one image depth for each frequency sweep of the laser. Furthermore, a method for arbitrarily shaping the spectral intensity profile of the laser is presented, without requiring the step of numerical apodization. In combination, these two techniques enable sampling of the in-phase and quadrature signal with a slow analog-to-digital converter and allow for real-time display of en face projections even for highest axial scan rates. Image data generated with this technique is compared to en face images extracted from a three-dimensional OCT data set. This technique can allow for real-time visualization of arbitrarily oriented en face planes for the purpose of alignment, registration, or operator-guided survey scans while simultaneously maintaining the full capability of high-speed volumetric ss-OCT functionality.

  1. Real time en face Fourier-domain optical coherence tomography with direct hardware frequency demodulation

    Science.gov (United States)

    Biedermann, Benjamin R.; Wieser, Wolfgang; Eigenwillig, Christoph M.; Palte, Gesa; Adler, Desmond C.; Srinivasan, Vivek J.; Fujimoto, James G.; Huber, Robert

    2009-01-01

    We demonstrate en face swept source optical coherence tomography (ss-OCT) without requiring a Fourier transformation step. The electronic optical coherence tomography (OCT) interference signal from a k-space linear Fourier domain mode-locked laser is mixed with an adjustable local oscillator, yielding the analytic reflectance signal from one image depth for each frequency sweep of the laser. Furthermore, a method for arbitrarily shaping the spectral intensity profile of the laser is presented, without requiring the step of numerical apodization. In combination, these two techniques enable sampling of the in-phase and quadrature signal with a slow analog-to-digital converter and allow for real-time display of en face projections even for highest axial scan rates. Image data generated with this technique is compared to en face images extracted from a three-dimensional OCT data set. This technique can allow for real-time visualization of arbitrarily oriented en face planes for the purpose of alignment, registration, or operator-guided survey scans while simultaneously maintaining the full capability of high-speed volumetric ss-OCT functionality. PMID:18978919

  2. Non-destructive inspection methods for LEDs using real-time displaying Optical Coherence Tomography.

    Science.gov (United States)

    Cho, Nam Hyun; Jung, Unsang; Kim, Suhwan; Kim, Jeehyun

    2012-01-01

    In this study, we report the applicability of two different Optical Coherence Tomography (OCT) technologies for inspecting Light Emitting Diode (LED) structures. Sectional images of a LED were captured using a Spectral Domain OCT (SD-OCT) system and a Swept Source OCT (SS-OCT) system. Their center wavelengths are 850 and 1,310 nm, respectively. We acquired cross-sectional two dimensional (2D) images of a normal LED and extracted sectional profiles to inspect possible wire disconnection that may be present in the LED manufacturing process. The SD-OCT and SS-OCT images were compared with each other in the same sample to study their advantages. The distribution of fluorescence material was observed more clearly with the SD-OCT of 850 nm wavelength, whereas the status of wire connection was clearer in the SS-OCT images with 1,310 nm wavelength. In addition, the volume of the fluorophore space was calculated from the OCT images. This is the first report that a nondestructive optical imaging modality such as OCT can be applied to finding screen defects in LED. We expect this method can improve the inspection efficacy over traditional inspection methods such as Charged Coupled Device (CCD) camera or X-ray instruments.

  3. Non-Destructive Inspection Methods for LEDs Using Real-Time Displaying Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Suhwan Kim

    2012-07-01

    Full Text Available In this study, we report the applicability of two different Optical Coherence Tomography (OCT technologies for inspecting Light Emitting Diode (LED structures. Sectional images of a LED were captured using a Spectral Domain OCT (SD-OCT system and a Swept Source OCT (SS-OCT system. Their center wavelengths are 850 and 1,310 nm, respectively. We acquired cross-sectional two dimensional (2D images of a normal LED and extracted sectional profiles to inspect possible wire disconnection that may be present in the LED manufacturing process. The SD-OCT and SS-OCT images were compared with each other in the same sample to study their advantages. The distribution of fluorescence material was observed more clearly with the SD-OCT of 850 nm wavelength, whereas the status of wire connection was clearer in the SS-OCT images with 1,310 nm wavelength. In addition, the volume of the fluorophore space was calculated from the OCT images. This is the first report that a nondestructive optical imaging modality such as OCT can be applied to finding screen defects in LED. We expect this method can improve the inspection efficacy over traditional inspection methods such as Charged Coupled Device (CCD camera or X-ray instruments.

  4. Long working distance optical coherence tomography for pediatric imaging (Conference Presentation)

    Science.gov (United States)

    Qian, Ruobing; Carrasco-Zevallos, Oscar; Vajzovic, Lejla; Gramatikov, Boris I.; Guyton, David L.; Toth, Cynthia A.; Izatt, Joseph A.

    2016-03-01

    Conventional optical coherence tomography (OCT) systems have working distances of about 25 mm, and require cooperative subjects to immobilize and fixate on a target. Handheld OCT probes have also been demonstrated for successful imaging of pre-term infants and neonates up to ~1 year old. However, no technology yet exists for OCT in young children due to their lack of attention and inherent fear of large objects close to their face. In this work, we demonstrate a prototype retinal swept-source OCT system with a long working distance (from the last optical element to the subject's eye) to facilitate pediatric imaging. To reduce the footprint and weight of the system compared to the conventional 4f scheme, a novel 2f scanning configuration was implemented to achieve a working distance of 348mm with a +/- 8° scanning angle prior to cornea. Employing two custom-designed lenses, the system design resolution was nearly diffraction limited throughout a -8D to +5D refractive corrections. A fixation target displayed on a LCD monitor and an iris camera were used to facilitate alignment and imaging. Our prototype was tested in consented adult subjects and has the potential to facilitate imaging of young children. With this apparatus, young children could potentially sit comfortably in caretaker's lap while viewing entertainment on the fixation screen designed to direct their gaze into the imaging apparatus.

  5. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease

    Directory of Open Access Journals (Sweden)

    Panagiotis Giannakouras

    2017-07-01

    Full Text Available Purpose: To report a case of Vogt-Koyanagi-Harada (VKH disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA. Methods: Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT were performed at baseline, as well as OCTA. Results: A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. Conclusions and Importance: VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  6. Imaging of ex vivo nonmelanoma skin cancers in the optical and terahertz spectral regions optical and terahertz skin cancers imaging.

    Science.gov (United States)

    Joseph, Cecil S; Patel, Rakesh; Neel, Victor A; Giles, Robert H; Yaroslavsky, Anna N

    2014-05-01

    We tested the hypothesis that polarization sensitive optical and terahertz imaging may be combined for accurate nonmelanoma skin cancer (NMSC) delineation. Nine NMSC specimens were imaged. 513 μm and 440 nm wavelengths were used for terahertz and optical imaging, respectively. Histopathology was processed for evaluation. Terahertz reflectance of NMSC was quantified. Our results demonstrate that cross-polarized terahertz images correctly identified location of the tumours, whereas cross-polarized and polarization difference optical images accurately presented morphological features. Cross-polarized terahertz images exhibited lower reflectivity values in cancer as compared to normal tissue. Combination of optical and terahertz imaging shows promise for intraoperative delineation of NMSC. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  8. Common path endoscopic probes for optical coherence tomography (Conference Presentation)

    Science.gov (United States)

    Singh, Kanwarpal; Gardecki, Joseph A.; Tearney, Guillermo J.

    2017-02-01

    Background: Dispersion imbalance and polarization mismatch between the reference and sample arm signals can lead to image quality degradation in optical coherence tomography (OCT). One approach to reduce these image artifacts is to employ a common-path geometry in fiber-based probes. In this work, we report an 800 um diameter all-fiber common-path monolithic probe for coronary artery imaging where the reference signal is generated using an inline fiber partial reflector. Methods: Our common-path probe was designed for swept-source based Fourier domain OCT at 1310 nm wavelength. A face of a coreless fiber was coated with gold and spliced to a standard SMF-28 single mode fiber creating an inline partial reflector, which acted as a reference surface. The other face of the coreless fiber was shaped into a ball lens for focusing. The optical elements were assembled within a 560 µm diameter drive shaft, which was attached to a rotary junction. The drive shaft was placed inside a transparent sheath having an outer diameter of 800 µm. Results: With a source input power of 30mW, the inline common-path probe achieved a sensitivity of 104 dB. Images of human finger skin showed the characteristic layers of skin as well as features such as sweat ducts. Images of coronary arteries ex vivo obtained with this probe enabled visualization of the characteristic architectural morphology of the normal artery wall and known features of atherosclerotic plaque. Conclusion: In this work, we have demonstrated a common path OCT probe for cardiovascular imaging. The probe is easy to fabricate, will reduce system complexity and overall cost. We believe that this design will be helpful in endoscopic applications that require high resolution and a compact form factor.

  9. OCT-Based Quantification and Classification of Optic Disc Structure in Glaucoma Patients.

    Directory of Open Access Journals (Sweden)

    Naoko Takada

    Full Text Available To objectively classify the optic discs of open-angle glaucoma (OAG patients into Nicolela's four disc types, i.e., focal ischemic (FI, myopic (MY, senile sclerotic (SS, and generalized enlargement (GE, with swept-source optical coherence tomography (SS-OCT.This study enrolled 113 eyes of 113 OAG patients (mean age: 62.5 ± 12.6; Humphrey field analyzer-measured mean deviation: -9.4 ± 7.3 dB. Newly developed software was used to quantify a total of 20 optic disc parameters in SS-OCT (DRI OCT-1, TOPCON images of the optic disc. The most suitable reference plane (RP above the plane of Bruch's membrane opening was determined by comparing, at various RP heights, the SS-OCT-measured rim parameters and spectral-domain OCT-measured circumpapillary retinal nerve fiber layer thickness (cpRNFLT, with Pearson's correlation analysis. To obtain a discriminant formula for disc type classification, a training group of 72 eyes of 72 OAG patients and a validation group of 60 eyes of 60 OAG patients were set up.Correlation with cpRNFLT differed with disc type and RP height, but overall, a height of 120 μm minimized the influence of disc type. Six parameters were most significant for disc type discrimination: disc angle (horizontal, average cup depth, cup/disc ratio, rim-decentering ratio, average rim/disc ratio (upper and lower nasal. Classifying the validation group with these parameters returned an identification rate of 80.0% and a Cohen's Kappa of 0.73.Our new, objective SS-OCT-based method enabled us to classify glaucomatous optic discs with high reproducibility and accuracy.

  10. Added soft tissue contrast using signal attenuation and the fractal dimension for optical coherence tomography images of porcine arterial tissue

    International Nuclear Information System (INIS)

    Flueraru, C; Mao, Y; Chang, S; Popescu, D P; Sowa, M G

    2010-01-01

    Optical coherence tomography (OCT) images of left-descending coronary tissues harvested from three porcine specimens were acquired with a home-build swept-source OCT setup. Despite the fact that OCT is capable of acquiring high resolution circumferential images of vessels, many distinct histological features of a vessel have comparable optical properties leading to poor contrast in OCT images. Two classification methods were tested in this report for the purpose of enhancing contrast between soft-tissue components of porcine coronary vessels. One method involved analyzing the attenuation of the OCT signal as a function of light penetration into the tissue. We demonstrated that by analyzing the signal attenuation in this manner we were able to differentiate two media sub-layers with different orientations of the smooth muscle cells. The other classification method used in our study was fractal analysis. Fractal analysis was implemented in a box-counting (fractal dimension) image-processing code and was used as a tool to differentiate and quantify variations in tissue texture at various locations in the OCT images. The calculated average fractal dimensions had different values in distinct regions of interest (ROI) within the imaged coronary samples. When compared to the results obtained by using the attenuation of the OCT signal, the method of fractal analysis demonstrated better classification potential for distinguishing amongst the tissue ROI.

  11. Viscoelastic characterization of dispersive media by inversion of a general wave propagation model in optical coherence elastography

    Science.gov (United States)

    Zvietcovich, Fernando; Rolland, Jannick P.; Grygotis, Emma; Wayson, Sarah; Helguera, Maria; Dalecki, Diane; Parker, Kevin J.

    2018-02-01

    Determining the mechanical properties of tissue such as elasticity and viscosity is fundamental for better understanding and assessment of pathological and physiological processes. Dynamic optical coherence elastography uses shear/surface wave propagation to estimate frequency-dependent wave speed and Young's modulus. However, for dispersive tissues, the displacement pulse is highly damped and distorted during propagation, diminishing the effectiveness of peak tracking approaches. The majority of methods used to determine mechanical properties assume a rheological model of tissue for the calculation of viscoelastic parameters. Further, plane wave propagation is sometimes assumed which contributes to estimation errors. To overcome these limitations, we invert a general wave propagation model which incorporates (1) the initial force shape of the excitation pulse in the space-time field, (2) wave speed dispersion, (3) wave attenuation caused by the material properties of the sample, (4) wave spreading caused by the outward cylindrical propagation of the wavefronts, and (5) the rheological-independent estimation of the dispersive medium. Experiments were conducted in elastic and viscous tissue-mimicking phantoms by producing a Gaussian push using acoustic radiation force excitation, and measuring the wave propagation using a swept-source frequency domain optical coherence tomography system. Results confirm the effectiveness of the inversion method in estimating viscoelasticity in both the viscous and elastic phantoms when compared to mechanical measurements. Finally, the viscoelastic characterization of collagen hydrogels was conducted. Preliminary results indicate a relationship between collagen concentration and viscoelastic parameters which is important for tissue engineering applications.

  12. The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography.

    Science.gov (United States)

    Nakamine, Sakari; Sakai, Hiroshi; Arakaki, Yoshikuni; Yonahara, Michiko; Kaiya, Tadayoshi

    2018-01-01

    To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.

  13. Comparison of three-dimensional optical coherence tomography and high resolution photography for art conservation studies.

    Science.gov (United States)

    Adler, Desmond C; Stenger, Jens; Gorczynska, Iwona; Lie, Henry; Hensick, Teri; Spronk, Ron; Wolohojian, Stephan; Khandekar, Narayan; Jiang, James Y; Barry, Scott; Cable, Alex E; Huber, Robert; Fujimoto, James G

    2007-11-26

    Gold punchwork and underdrawing in Renaissance panel paintings are analyzed using both three-dimensional swept source / Fourier domain optical coherence tomography (3D-OCT) and high resolution digital photography. 3D-OCT can generate en face images with micrometer-scale resolutions at arbitrary sectioning depths, rejecting out-of-plane light by coherence gating. Therefore 3D-OCT is well suited for analyzing artwork where a surface layer obscures details of interest. 3D-OCT also enables cross-sectional imaging and quantitative measurement of 3D features such as punch depth, which is beneficial for analyzing the tools and techniques used to create works of art. High volumetric imaging speeds are enabled by the use of a Fourier domain mode locked (FDML) laser as the 3D-OCT light source. High resolution infrared (IR) digital photography is shown to be particularly useful for the analysis of underdrawing, where the materials used for the underdrawing and paint layers have significantly different IR absrption properties. In general, 3D-OCT provides a more flexible and comprehensive analysis of artwork than high resolution photography, but also requires more complex instrumentation and data analysis.

  14. Lamellar keratoplasty using position-guided surgical needle and M-mode optical coherence tomography

    Science.gov (United States)

    Shin, Sungwon; Bae, Jung Kweon; Ahn, Yujin; Kim, Hyeongeun; Choi, Geonho; Yoo, Young-Sik; Joo, Choun-Ki; Moon, Sucbei; Jung, Woonggyu

    2017-12-01

    Deep anterior lamellar keratoplasty (DALK) is an emerging surgical technique for the restoration of corneal clarity and vision acuity. The big-bubble technique in DALK surgery is the most essential procedure that includes the air injection through a thin syringe needle to separate the dysfunctional region of the cornea. Even though DALK is a well-known transplant method, it is still challenged to manipulate the needle inside the cornea under the surgical microscope, which varies its surgical yield. Here, we introduce the DALK protocol based on the position-guided needle and M-mode optical coherence tomography (OCT). Depth-resolved 26-gage needle was specially designed, fabricated by the stepwise transitional core fiber, and integrated with the swept source OCT system. Since our device is feasible to provide both the position information inside the cornea as well as air injection, it enables the accurate management of bubble formation during DALK. Our results show that real-time feedback of needle end position was intuitionally visualized and fast enough to adjust the location of the needle. Through our research, we realized that position-guided needle combined with M-mode OCT is a very efficient and promising surgical tool, which also to enhance the accuracy and stability of DALK.

  15. Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries.

    Science.gov (United States)

    Pasricha, Neel Dave; Bhullar, Paramjit Kaur; Shieh, Christine; Viehland, Christian; Carrasco-Zevallos, Oscar Mijail; Keller, Brenton; Izatt, Joseph Adam; Toth, Cynthia Ann; Challa, Pratap; Kuo, Anthony Nanlin

    2017-01-01

    We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe open-angle glaucoma and elevated intraocular pressure (IOP) that was not adequately managed by medical intervention or prior surgery. We performed tube shunt placement and trabeculectomy surgery and used SS-MIOCT to visualize and record surgical steps that benefitted from the enhanced visualization. In the case of tube shunt placement, SS-MIOCT successfully visualized the scleral tunneling, tube shunt positioning in the anterior chamber, and tube shunt suturing. For the trabeculectomy, SS-MIOCT successfully visualized the scleral flap creation, sclerotomy, and iridectomy. Postoperatively, both patients did well, with IOPs decreasing to the target goal. We found the benefit of SS-MIOCT was greatest in surgical steps requiring depth-based assessments. This technology has the potential to improve clinical outcomes.

  16. Combined two-photon microscopy and optical coherence tomography using individually optimized sources

    Science.gov (United States)

    Jeong, Bosu; Lee, Byunghak; Jang, Min Seong; Nam, Hyoseok; Kim, Hae Koo; Yoon, Sang June; Doh, Junsang; Lee, Sang-Joon; Yang, Bo-Gie; Jang, Myoung Ho; Kim, Ki Hean

    2011-03-01

    Two-photon microscopy (TPM) and optical coherence tomography (OCT) are 3D tissue imaging techniques based on different contrast mechanisms. We developed a combined system of TPM and OCT to provide information of both imaging modalities for in-vivo tissue study. TPM and OCT were implemented by using separate light sources, a Ti-Sapphire laser and a wavelength-swept source centered at 1300 nm respectively, and scanners. Light from the two sources was combined for the simultaneous imaging of tissue samples. TPM provided molecular, cellular information of tissues in the region of a few hundred microns on one side at a sub-cellular resolution, and ran at approximately 40 frames per second. OCT provided structural information in the tissue region larger than TPM images at a sub-tenth micron resolution by using 0.1 numerical aperture. OCT had the field of view of 800 um × 800 um based on a 20x objective, the sensitivity of 97dB, and the imaging speed of 0.8 volumes per second. This combined system was tested with simple microsphere specimens, and then was applied to image the explanted intestine of a mouse model and the plant leaves. Morphology and micro-structures of the intestine villi and immune cells within the villi were shown in the intestine image, and chloroplasts and various microstructures of the maize leaves were visualized in 3D by the combined system.

  17. Optical coherence tomography imaging of colonic crypts in a mouse model of colorectal cancer

    Science.gov (United States)

    Welge, Weston A.; Barton, Jennifer K.

    2016-03-01

    Aberrant crypt foci (ACF) are abnormal epithelial lesions that precede development of colonic polyps. As the earliest morphological change in the development of colorectal cancer, ACF is a highly studied phenomenon. The most common method of imaging ACF is chromoendoscopy using methylene blue as a contrast agent. Narrow- band imaging is a contrast-agent-free modality for imaging the colonic crypts. Optical coherence tomography (OCT) is an attractive alternative to chromoendoscopy and narrow-band imaging because it can resolve the crypt structure at sufficiently high sampling while simultaneously providing depth-resolved data. We imaged in vivo the distal 15 mm of colon in the azoxymethane (AOM) mouse model of colorectal cancer using a commercial swept-source OCT system and a miniature endoscope designed and built in-house. We present en face images of the colonic crypts and demonstrate that different patterns in healthy and adenoma tissue can be seen. These patterns correspond to those reported in the literature. We have previously demonstrated early detection of colon adenoma using OCT by detecting minute thickening of the mucosa. By combining mucosal thickness measurement with imaging of the crypt structure, OCT can be used to correlate ACF and adenoma development in space and time. These results suggest that OCT may be a superior imaging modality for studying the connection between ACF and colorectal cancer.

  18. Optical coherence tomography for blood glucose monitoring in vitro through spatial and temporal approaches

    Science.gov (United States)

    De Pretto, Lucas Ramos; Yoshimura, Tania Mateus; Ribeiro, Martha Simões; Zanardi de Freitas, Anderson

    2016-08-01

    As diabetes causes millions of deaths worldwide every year, new methods for blood glucose monitoring are in demand. Noninvasive approaches may increase patient adherence to treatment while reducing costs, and optical coherence tomography (OCT) may be a feasible alternative to current invasive diagnostics. This study presents two methods for blood sugar monitoring with OCT in vitro. The first, based on spatial statistics, exploits changes in the light total attenuation coefficient caused by different concentrations of glucose in the sample using a 930-nm commercial OCT system. The second, based on temporal analysis, calculates differences in the decorrelation time of the speckle pattern in the OCT signal due to blood viscosity variations with the addition of glucose with data acquired by a custom built Swept Source 1325-nm OCT system. Samples consisted of heparinized mouse blood, phosphate buffer saline, and glucose. Additionally, further samples were prepared by diluting mouse blood with isotonic saline solution to verify the effect of higher multiple scattering components on the ability of the methods to differentiate glucose levels. Our results suggest a direct relationship between glucose concentration and both decorrelation rate and attenuation coefficient, with our systems being able to detect changes of 65 mg/dL in glucose concentration.

  19. Dental optical coherence tomography: new potential diagnostic system for cracked-tooth syndrome.

    Science.gov (United States)

    Lee, Sang-Hee; Lee, Jong-Jin; Chung, Hyun-Jin; Park, Jong-Tae; Kim, Hee-Jin

    2016-01-01

    The aim of the present study was to determine the reliability of optical coherence tomography (OCT) in detecting cracked teeth and its relative clinical effectiveness by comparing it with other diagnostic methods including conventional visual inspection, trans-illumination, and micro-computed tomography (micro-CT). The reliability of swept source OCT (SS-OCT) was verified by comparing the number of detected crack lines on 109 surfaces of 61 teeth with those detected with other conventional methods. One to one comparison revealed that crack lines that were invisible with naked eyes could be found in SS-OCT images. The detection ability of SS-OCT was superior or similar to those of micro-CT (100.0 %) and trans-illumination. Crack lines shown in the SS-OCT images had distinct characteristics, and structural crack lines and craze lines could be distinguished in SS-OCT images. Thus, the detection ability of SS-OCT renders it an acceptable diagnostic device for cracked-tooth syndrome.

  20. Evaluation of the marginal fit at implant-abutment interface by optical coherence tomography

    Science.gov (United States)

    Kikuchi, Keisuke; Akiba, Norihisa; Sadr, Alireza; Sumi, Yasunori; Tagami, Junji; Minakuchi, Shunsuke

    2014-05-01

    Vertical misfit of implant-abutment interface can affect the success of implant treatment; however, currently available modalities have limitations to detect these gaps. This study aimed to evaluate implant-abutment gaps in vitro using optical coherence tomography (OCT). Vertical misfit gaps sized 50, 100, 150, or 200 μm were created between external hexagonal implants and titanium abutments (Nobel Biocare, Göteborg, Sweden). A porcine gingival tissue slice, 0.5, 1.0, 1.5, or 2.0 mm in thickness, was placed on each implant-abutment interface. The gaps were evaluated by swept-source OCT at a center wavelength of 1330 nm (Panasonic Healthcare, Ehime, Japan) with beam angles of 90, 75 and 60 deg to the implant long-axis. The results suggested that while the measurements were precise, gap size and gingival thickness affected the sensitivity of detection. Gaps sized 100 μm and above could be detected with good accuracy under 0.5- or 1.0-mm-thick gingiva (GN). Around 70% of gaps sized 150 μm and above could be detected under 1.5-mm-thick GN. On the other hand, 80% of gaps under 2.0-mm-thick GN were not detected due to attenuation of near-infrared light through the soft tissue. OCT appeared as an effective tool for evaluating the misfit of implant-abutment under thin layers of soft tissue.

  1. Dual-wavelength photothermal optical coherence tomography for blood oxygen saturation measurement

    Science.gov (United States)

    Yin, Biwei; Kuranov, Roman V.; McElroy, Austin B.; Milner, Thomas E.

    2013-03-01

    We report design and demonstration of a dual wavelength photothermal (DWP) optical coherence tomography (OCT) system for imaging of a phantom microvessel and measurement of hemoglobin oxygen saturation (SO2) level. The DWP-OCT system contains a swept-source (SS) two-beam phase-sensitive (PhS) OCT system (1060 nm) and two intensity modulated photothermal excitation lasers (770 nm and 800 nm). The PhS-OCT probe beam (1060 nm) and photothermal excitation beams are combined into one single-mode optical fiber. A galvanometer based two-dimensional achromatic scanning system is designed to provide 14 μm lateral resolution for the PhS-OCT probe beam (1060 nm) and 13 μm lateral resolution for photothermal excitation beams. DWP-OCT system's sensitivity is 102 dB, axial resolution is 13 μm in tissue and uses a real-time digital dispersion compensation algorithm. Noise floor for optical pathlength measurements is 300 pm in the signal frequency range (380-400 Hz) of photothermal modulation frequencies. Blood SO2 level is calculated from measured optical pathlength (op) signal in a 300 μm diameter microvessel phantom introduced by the two photothermal excitation beams. En-face and B-scan images of a phantom microvessel are recorded, and six blood samples' SO2 levels are measured using DWP-OCT and compared with values provided by a commercial blood oximeter. A mathematical model indicates thermal diffusion introduces a systematic artifact that over-estimates SO2 values and is consistent with measured data.

  2. Automatic detection of tooth cracks in optical coherence tomography images.

    Science.gov (United States)

    Kim, Jun-Min; Kang, Se-Ryong; Yi, Won-Jin

    2017-02-01

    The aims of the present study were to compare the image quality and visibility of tooth cracks between conventional methods and swept-source optical coherence tomography (SS-OCT) and to develop an automatic detection technique for tooth cracks by SS-OCT imaging. We evaluated SS-OCT with a near-infrared wavelength centered at 1,310 nm over a spectral bandwidth of 100 nm at a rate of 50 kHz as a new diagnostic tool for the detection of tooth cracks. The reliability of the SS-OCT images was verified by comparing the crack lines with those detected using conventional methods. After performing preprocessing of the obtained SS-OCT images to emphasize cracks, an algorithm was developed and verified to detect tooth cracks automatically. The detection capability of SS-OCT was superior or comparable to that of trans-illumination, which did not discriminate among the cracks according to depth. Other conventional methods for the detection of tooth cracks did not sense initial cracks with a width of less than 100 μm. However, SS-OCT detected cracks of all sizes, ranging from craze lines to split teeth, and the crack lines were automatically detected in images using the Hough transform. We were able to distinguish structural cracks, craze lines, and split lines in tooth cracks using SS-OCT images, and to automatically detect the position of various cracks in the OCT images. Therefore, the detection capability of SS-OCT images provides a useful diagnostic tool for cracked tooth syndrome.

  3. The Optical Design and Characterization of the Microwave Anisotropy Probe

    Science.gov (United States)

    Page, L.; Jackson, C.; Barnes, C.; Bennett, C.; Halpern, M.; Hinshaw, G.; Jarosik, N.; Kogut, A.; Limon, M.; Meyer, S. S.; Spergel, D. N.; Tucker, G. S.; Wilkinson, D. T.; Wollack, E.; Wright, E. L.

    2003-03-01

    The primary goal of the MAP satellite, now in orbit, is to make high-fidelity polarization-sensitive maps of the full sky in five frequency bands between 20 and 100 GHz. From these maps we will characterize the properties of the cosmic microwave background (CMB) anisotropy and Galactic and extragalactic emission on angular scales ranging from the effective beam size, less than 0.23d, to the full sky. MAP is a differential microwave radiometer. Two back-to-back shaped offset Gregorian telescopes feed two mirror symmetric arrays of 10 corrugated feeds. We describe the prelaunch design and characterization of the optical system, compare the optical models to the measurements, and consider multiple possible sources of systematic error.

  4. Mueller-matrix modeling and characterization of a dual-crystal electro-optic modulator.

    Science.gov (United States)

    Cervantes-L, Joel; Serrano-Garcia, David I; Otani, Yukitoshi; Cense, Barry

    2016-10-17

    A general mathematical model based on Mueller-matrix calculation is presented to describe the optical behavior of a dual-crystal electro-optic modulator. The two crystals inside the modulator are oriented at ± 45° with respect to the horizontal, thereby cancelling natural birefringence and temperature-induced birefringence. We describe the behavior of the modulator as a function of the ellipticity of the crystals, the rotation angles of the crystals and the applied voltage. By fitting the measured data with a Mueller-matrix model that uses values for the ellipticity and orientation angles of the crystals, the simulated data and the experimental measurements could be matched. This Mueller-matrix includes physical properties of the thermally compensated electro optic modulator, and the matrix can be used in simulations where these device-specific properties are important, for instance in the modeling of a polarization-sensitive optical coherence tomography system.

  5. Evaluation of optical coherence tomography for the measurement of the effects of activators and anticoagulants on the blood coagulation in vitro.

    Science.gov (United States)

    Xu, Xiangqun; Geng, Jinhai; Liu, Gangjun; Chen, Zhongping

    2013-08-01

    Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d(1/e)) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening.

  6. Morphological analysis of the growth stages of in-vivo mouse hair follicles by using optical coherence tomography

    Science.gov (United States)

    Jha, Rakesh Kumar; Kim, Kanghae; Jeon, Mansik; Kim, Jeehyun; Kang, Minyoung; Han, Insook; Kim, Moonkyu

    2016-09-01

    Swept-source optical coherence tomography (SS-OCT), a bio-photonic imaging modality, was used to demonstrate an initial feasibility experiment for detecting morphological variations of in-vivo mouse hair follicles for the anagen and the telogen growth stages. Two C57BL/6 adult male mice, one undergoing the anagen stage and the other undergoing the telogen stage of the hair follicle growth cycle, were selected for the experiment. The OCT cross-sectional images of mice skin were acquired in-vivo within an interval of 15 days, and the observed morphological changes were analyzed. The micro-structural features of mice skin on the 15th experimental day were further compared with corresponding histological observations. The preliminary result of this study provides clear insights into the structural details of mouse skin, confirming the resemblance of the OCT images with the corresponding histological measurements, and ensures the suitability of SS-OCT for non-invasive analysis of hair follicle conditions.

  7. Microscope-Integrated Optical Coherence Tomography Angiography in the Operating Room in Young Children With Retinal Vascular Disease.

    Science.gov (United States)

    Chen, Xi; Viehland, Christian; Carrasco-Zevallos, Oscar M; Keller, Brenton; Vajzovic, Lejla; Izatt, Joseph A; Toth, Cynthia A

    2017-05-01

    Intraoperative optical coherence tomography (OCT) has gained traction as an important adjunct for clinical decision making during vitreoretinal surgery, and OCT angiography (OCTA) has provided novel insights in clinical evaluation of retinal diseases. To date, these two technologies have not been applied in combination to evaluate retinal vascular disease in the operating suite. To conduct microscope-integrated, swept-source OCTA (MIOCTA) in children with retinal vascular disease. In this case report analysis, OCT imaging in pediatric patients, MIOCTA images were obtained during examination under anesthesia from a young boy with a history of idiopathic vitreous hemorrhage and a female infant with familial exudative vitreoretinopathy. Side-by-side comparison of research MIOCT angiograms and clinically indicated fluorescein angiograms. In 2 young children with retinal vascular disease, the MIOCTA images showed more detailed vascular patterns than were visible on the fluorescein angiograms although within a more posterior field of view. The MIOCTA system allowed visualization of small pathological retinal vessels in the retinal periphery that were obscured in the fluorescein angiograms by fluorescein staining from underlying, preexisting laser scars. This is the first report to date of the use of MIOCTA in the operating room for young children with retinal vascular disease. Further optimization of this system may allow noninvasive detailed evaluation of retinal vasculature during surgical procedures and in patients who could not cooperate with in-office examinations.

  8. Sapphire ball lensed fiber probe for common-path optical coherence tomography in ocular imaging and sensing.

    Science.gov (United States)

    Zhao, Mingtao; Huang, Yong; Kang, Jin U

    2013-03-26

    We describe a novel common-path optical coherence tomography (CP-OCT) fiber probe design using a sapphire ball lens for cross-sectional imaging and sensing in retina vitrectomy surgery. Single mode Gaussian beam (TEM 00 ) simulation was used to optimize lateral resolution and working distance (WD) of the common-path probe. A theoretical sensitivity model for CP-OCT was prosed to assess its optimal performance based an unbalanced photodetector configuration. Two probe designs with working distances (WD) 415μm and 1221μm and lateral resolution 11μm and 18μm, respectively were implemented with sensitivity up to 88dB. The designs are also fully compatible with conventional Michelson interferometer based OCT configurations. The reference plane of the probe, located at the distal beam exit interface of the single mode fiber (SMF), was encased within a 25-gauge hypodermic needle by the sapphire ball lens facilitates its applications in bloody and harsh environments. The performances of the fiber probe with 11μm of lateral resolution and 19μm of axial resolution were demonstrated by cross-sectional imaging of a cow cornea and retina in vitro with a 1310nm swept source OCT system. This probe was also attached to a piezoelectric motor for active compensation of physiological tremor for handheld retinal surgical tools.

  9. Optic neuritis

    Science.gov (United States)

    Retro-bulbar neuritis; Multiple sclerosis - optic neuritis; Optic nerve - optic neuritis ... The exact cause of optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when ...

  10. Combined multimodal photoacoustic tomography, optical coherence tomography (OCT) and OCT based angiography system for in vivo imaging of multiple skin disorders in human(Conference Presentation)

    Science.gov (United States)

    Liu, Mengyang; Chen, Zhe; Sinz, Christoph; Rank, Elisabet; Zabihian, Behrooz; Zhang, Edward Z.; Beard, Paul C.; Kittler, Harald; Drexler, Wolfgang

    2017-02-01

    All optical photoacoustic tomography (PAT) using a planar Fabry-Perot interferometer polymer film sensor has been demonstrated for in vivo human palm imaging with an imaging penetration depth of 5 mm. The relatively larger vessels in the superficial plexus and the vessels in the dermal plexus are visible in PAT. However, due to both resolution and sensitivity limits, all optical PAT cannot reveal the smaller vessels such as capillary loops and venules. Melanin absorption also sometimes causes difficulties in PAT to resolve vessels. Optical coherence tomography (OCT) based angiography, on the other hand, has been proven suitable for microvasculature visualization in the first couple millimeters in human. In our work, we combine an all optical PAT system with an OCT system featuring a phase stable akinetic swept source. This multimodal PAT/OCT/OCT-angiography system provides us co-registered human skin vasculature information as well as the structural information of cutaneous. The scanning units of the sub-systems are assembled into one probe, which is then mounted onto a portable rack. The probe and rack design gives six degrees of freedom, allowing the multimodal optical imaging probe to access nearly all regions of human body. Utilizing this probe, we perform imaging on patients with various skin disorders as well as on healthy controls. Fused PAT/OCT-angiography volume shows the complete blood vessel network in human skin, which is further embedded in the morphology provided by OCT. A comparison between the results from the disordered regions and the normal regions demonstrates the clinical translational value of this multimodal optical imaging system in dermatology.

  11. Multimodal ophthalmic imaging using spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography

    Science.gov (United States)

    El-Haddad, Mohamed T.; Malone, Joseph D.; Li, Jianwei D.; Bozic, Ivan; Arquitola, Amber M.; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2017-08-01

    Ophthalmic surgery involves manipulation of delicate, layered tissue structures on milli- to micrometer scales. Traditional surgical microscopes provide an inherently two-dimensional view of the surgical field with limited depth perception which precludes accurate depth-resolved visualization of these tissue layers, and limits the development of novel surgical techniques. We demonstrate multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography (SS-SESLO-OCT) to address current limitations of image-guided ophthalmic microsurgery. SS-SESLO-OCT provides inherently co-registered en face and cross-sectional field-of-views (FOVs) at a line rate of 400 kHz and >2 GPix/s throughput. We show in vivo imaging of the anterior segment and retinal fundus of a healthy volunteer, and preliminary results of multi-volumetric mosaicking for ultrawide-field retinal imaging with 90° FOV. Additionally, a scan-head was rapid-prototyped with a modular architecture which enabled integration of SS-SESLO-OCT with traditional surgical microscope and slit-lamp imaging optics. Ex vivo surgical maneuvers were simulated in cadaveric porcine eyes. The system throughput enabled volumetric acquisition at 10 volumes-per-second (vps) and allowed visualization of surgical dynamics in corneal sweeps, compressions, and dissections, and retinal sweeps, compressions, and elevations. SESLO en face images enabled simple real-time co-registration with the surgical microscope FOV, and OCT cross-sections provided depth-resolved visualization of instrument-tissue interactions. Finally, we demonstrate novel augmented-reality integration with the surgical view using segmentation overlays to aid surgical guidance. SS-SESLO-OCT may benefit clinical diagnostics by enabling aiming, registration, and mosaicking; and intraoperative imaging by allowing for real-time surgical feedback, instrument tracking, and overlays of computationally extracted biomarkers of disease.

  12. Quantifying the effects of UV-A/riboflavin crosslinking on the elastic anisotropy and hysteresis of the porcine cornea by noncontact optical coherence elastography

    Science.gov (United States)

    Singh, Manmohan; Li, Jiasong; Raghunathan, Raksha; Han, Zhaolong; Nair, Achuth; Liu, Chih-Hao; Aglyamov, Salavat R.; Twa, Michael D.; Larin, Kirill V.

    2017-02-01

    The collagen fibril orientation of the cornea can provide critical information about cornea tissue health because diseases such as keratoconus and therapeutic interventions such as UV-A/riboflavin corneal collagen crosslinking (CXL) can alter the ultrastructural arrangement of collagen fibrils. Here, we quantify the elastic anisotropy and hysteresis of in situ porcine corneas as a function of intraocular pressure (IOP) with noncontact optical coherence elastography. Moreover, the effects of UV-A riboflavin corneal collagen crosslinking on the elastic anisotropy and hysteresis were evaluated. The propagation of an air-pulse induced elastic wave was imaged at stepped meridional angles by a home built phasestabilized swept source OCE system. The stiffness of the cornea was translated from the velocity of the wave, and the elastic anisotropy was quantified by modifying the planar anisotropy coefficient. As the IOP increased, the stiffness of the corneas increased from 18 kPa at 15 mmHg IOP to 120 kPa at 30 mmHg IOP. While there was a measureable hysteresis, it was not significant. After CXL, the Young's modulus of the corneas significantly increased from 18 kPa to 44 kPa at 15 mmHg IOP. The mechanical anisotropy also increased significantly from 10 a.u. in the untreated corneas to 23 a.u. in the CXL treated corneas, 15 mmHg IOP. However, CXL did not change the elastic anisotropic orientation, and the mechanical anisotropic hysteresis was not significant after CXL.

  13. Evaluating the Effects of Riboflavin/UV-A and Rose-Bengal/Green Light Cross-Linking of the Rabbit Cornea by Noncontact Optical Coherence Elastography

    Science.gov (United States)

    Singh, Manmohan; Li, Jiasong; Han, Zhaolong; Vantipalli, Srilatha; Liu, Chih-Hao; Wu, Chen; Raghunathan, Raksha; Aglyamov, Salavat R.; Twa, Michael D.; Larin, Kirill V.

    2016-01-01

    Purpose The purpose of this study was to use noncontact optical coherence elastography (OCE) to evaluate and compare changes in biomechanical properties that occurred in rabbit cornea in situ after corneal collagen cross-linking by either of two techniques: ultraviolet-A (UV-A)/riboflavin or rose-Bengal/green light. Methods Low-amplitude (≤10 μm) elastic waves were induced in mature rabbit corneas by a focused air pulse. Elastic wave propagation was imaged by a phase-stabilized swept source OCE (PhS-SSOCE) system. Corneas were then cross-linked by either of two methods: UV-A/riboflavin (UV-CXL) or rose-Bengal/green light (RGX). Phase velocities of the elastic waves were fitted to a previously developed modified Rayleigh-Lamb frequency equation to obtain the viscoelasticity of the corneas before and after the cross-linking treatments. Micro-scale depth-resolved phase velocity distribution revealed the depth-wise heterogeneity of both cross-linking techniques. Results Under standard treatment settings, UV-CXL significantly increased the stiffness of the corneas by ∼47% (P corneas, whereas RGX affected only the anterior ∼16% of the corneas. Conclusions UV-CXL significantly strengthens the cornea, whereas RGX does not, and the effects of cross-linking by UV-CXL reach deeper into the cornea than cross-linking effects of RGX under similar conditions. PMID:27409461

  14. Necessity of angiotensin-converting enzyme-related gene for cardiac functions and longevity of Drosophila melanogaster assessed by optical coherence tomography

    Science.gov (United States)

    Liao, Fang-Tsu; Chang, Cheng-Yi; Su, Ming-Tsan; Kuo, Wen-Chuan

    2014-01-01

    Prior studies have established the necessity of an angiotensin-converting enzyme-related (ACER) gene for heart morphogenesis of Drosophila. Nevertheless, the physiology of ACER has yet to be comprehensively understood. Herein, we employed RNA interference to down-regulate the expression of ACER in Drosophila's heart and swept source optical coherence tomography to assess whether ACER is required for cardiac functions in living adult flies. Several contractile parameters of Drosophila heart, including the heart rate (HR), end-diastolic diameter (EDD), end-systolic diameter (ESD), percent fractional shortening (%FS), and stress-induced cardiac performance, are shown, which are age dependent. These age-dependent cardiac functions declined significantly when ACER was down-regulated. Moreover, the lifespans of ACER knock-down flies were significantly shorter than those of wild-type control flies. Thus, we posit that ACER, the Drosophila ortholog of mammalian angiotensin-converting enzyme 2 (ACE2), is essential for both heart physiology and longevity of animals. Since mammalian ACE2 controls many cardiovascular physiological features and is implicated in cardiomyopathies, our findings that ACER plays conserved roles in genetically tractable animals will pave the way for uncovering the genetic pathway that controls the renin-angiotensin system.

  15. Low aberration monolithic diffraction gratings for high performance optical spectrometers

    Science.gov (United States)

    Triebel, Peter; Moeller, Tobias; Diehl, Torsten; Gatto, Alexandre; Pesch, Alexander; Erdmann, Lars E.; Burkhardt, Matthias; Kalies, Alexander

    2017-09-01

    Gratings are the core element of the spectrometer. For imaging spectrometers beside the polarization sensitivity and efficiency the imaging quality of the diffraction grating is essential. Lenses and mirrors can be produced with lowest wavefront aberrations. Low aberration imaging quality of the grating is required not to limit the overall imaging quality of the instrument. Different types of spectrometers will lead to different requirements on the wavefront aberrations for their specific diffraction gratings. The wavefront aberration of an optical grating is a combination of the substrate wavefront and the grating wavefront. During the manufacturing process of the grating substrate different processes can be applied in order to minimize the wavefront aberrations. The imaging performance of the grating is also optimized due to the recording setup of the holography. This technology of holographically manufactured gratings is used for transmission and reflection gratings on different types of substrates like prisms, convex and concave spherical and aspherical surface shapes, free-form elements. All the manufactured gratings are monolithic and can be coated with high reflection and anti-reflection coatings. Prism substrates were used to manufacture monolithic GRISM elements for the UV to IR spectral range preferably working in transmission. Besides of transmission gratings, numerous spectrometer setups (e.g. Offner, Rowland circle, Czerny-Turner system layout) working on the optical design principles of reflection gratings. The present approach can be applied to manufacture high quality reflection gratings for the EUV to the IR. In this paper we report our latest results on manufacturing lowest wavefront aberration gratings based on holographic processes in order to enable at least diffraction limited complex spectrometric setups over certain wavelength ranges. Beside the results of low aberration gratings the latest achievements on improving efficiency together with

  16. Dynamics of superconducting order parameter through ultrafast normal-to-superconducting phase transition in Bi2Sr2CaCu2O8 +δ from multipulse polarization-resolved transient optical reflectivity

    Science.gov (United States)

    Madan, I.; Baranov, V. V.; Toda, Y.; Oda, M.; Kurosawa, T.; Kabanov, V. V.; Mertelj, T.; Mihailovic, D.

    2017-11-01

    A systematic temperature-dependent study of the femtosecond optical superconducting (SC) state destruction and recovery in Bi2Sr2CaCu2O8 +δ cuprate superconductor by means of the all-optical polarization-sensitive multipulse spectroscopy is presented. At low temperatures and a partial SC state suppression, an anisotropic SC-gap recovery time scale is suggested by the data. The SC state destruction and recovery dynamics are compared to the recent TR-ARPES-inferred SC-gap dynamics and a qualitative agreement is found. Using a phenomenological response function, the experimental data are also compared to time-dependent Ginzburg-Landau model simulations.

  17. Functional optical coherence tomography: principles and progress

    Science.gov (United States)

    Kim, Jina; Brown, William; Maher, Jason R.; Levinson, Howard; Wax, Adam

    2015-05-01

    In the past decade, several functional extensions of optical coherence tomography (OCT) have emerged, and this review highlights key advances in instrumentation, theoretical analysis, signal processing and clinical application of these extensions. We review five principal extensions: Doppler OCT (DOCT), polarization-sensitive OCT (PS-OCT), optical coherence elastography (OCE), spectroscopic OCT (SOCT), and molecular imaging OCT. The former three have been further developed with studies in both ex vivo and in vivo human tissues. This review emphasizes the newer techniques of SOCT and molecular imaging OCT, which show excellent potential for clinical application but have yet to be well reviewed in the literature. SOCT elucidates tissue characteristics, such as oxygenation and carcinogenesis, by detecting wavelength-dependent absorption and scattering of light in tissues. While SOCT measures endogenous biochemical distributions, molecular imaging OCT detects exogenous molecular contrast agents. These newer advances in functional OCT broaden the potential clinical application of OCT by providing novel ways to understand tissue activity that cannot be accomplished by other current imaging methodologies.

  18. Three-Dimensional Analysis of Enamel Crack Behavior Using Optical Coherence Tomography.

    Science.gov (United States)

    Segarra, M S; Shimada, Y; Sadr, A; Sumi, Y; Tagami, J

    2017-03-01

    The aim of this study was to nondestructively analyze enamel crack behavior on different areas of teeth using 3D swept source-optical coherence tomography (SS-OCT). Ten freshly extracted human teeth of each type on each arch ( n = 80 teeth) were inspected for enamel crack patterns on functional, contact and nonfunctional, or noncontact areas using 3D SS-OCT. The predominant crack pattern for each location on each specimen was noted and analyzed. The OCT observations were validated by direct observations of sectioned specimens under confocal laser scanning microscopy (CLSM). Cracks appeared as bright lines with SS-OCT, with 3 crack patterns identified: Type I - superficial horizontal cracks; Type II - vertically (occluso-gingival) oriented cracks; and Type III - hybrid or complicated cracks, a combination of a Type I and Type III cracks, which may or may not be confluent with each other. Type II cracks were predominant on noncontacting surfaces of incisors and canines and nonfunctional cusps of posterior teeth. Type I and III cracks were predominant on the contacting surfaces of incisors, cusps of canines, and functional cusps of posterior teeth. Cracks originating from the dental-enamel junction and enamel tufts, crack deflections, and the initiation of new cracks within the enamel (internal cracks) were observed as bright areas. CLSM observations corroborated the SS-OCT findings. We found that crack pattern, tooth type, and the location of the crack on the tooth exhibited a strong correlation. We show that the use of 3D SS-OCT permits for the nondestructive 3D imaging and analysis of enamel crack behavior in whole human teeth in vitro. 3D SS-OCT possesses potential for use in clinical studies for the analysis of enamel crack behavior.

  19. Multi-Channel Optical Coherence Elastography Using Relative and Absolute Shear-Wave Time of Flight.

    Directory of Open Access Journals (Sweden)

    Eli Elyas

    Full Text Available Elastography, the imaging of elastic properties of soft tissues, is well developed for macroscopic clinical imaging of soft tissues and can provide useful information about various pathological processes which is complementary to that provided by the original modality. Scaling down of this technique should ply the field of cellular biology with valuable information with regard to elastic properties of cells and their environment. This paper evaluates the potential to develop such a tool by modifying a commercial optical coherence tomography (OCT device to measure the speed of shear waves propagating in a three-dimensional (3D medium. A needle, embedded in the gel, was excited to vibrate along its long axis and the displacement as a function of time and distance from the needle associated with the resulting shear waves was detected using four M-mode images acquired simultaneously using a commercial four-channel swept-source OCT system. Shear-wave time of arrival (TOA was detected by tracking the axial OCT-speckle motion using cross-correlation methods. Shear-wave speed was then calculated from inter-channel differences of TOA for a single burst (the relative TOA method and compared with the shear-wave speed determined from positional differences of TOA for a single channel over multiple bursts (the absolute TOA method. For homogeneous gels the relative method provided shear-wave speed with acceptable precision and accuracy when judged against the expected linear dependence of shear modulus on gelatine concentration (R2 = 0.95 and ultimate resolution capabilities limited by 184μm inter-channel distance. This overall approach shows promise for its eventual provision as a research tool in cancer cell biology. Further work is required to optimize parameters such as vibration frequency, burst length and amplitude, and to assess the lateral and axial resolutions of this type of device as well as to create 3D elastograms.

  20. Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns.

    Science.gov (United States)

    Kraus, Martin F; Potsaid, Benjamin; Mayer, Markus A; Bock, Ruediger; Baumann, Bernhard; Liu, Jonathan J; Hornegger, Joachim; Fujimoto, James G

    2012-06-01

    High speed Optical Coherence Tomography (OCT) has made it possible to rapidly capture densely sampled 3D volume data. One key application is the acquisition of high quality in vivo volumetric data sets of the human retina. Since the volume is acquired in a few seconds, eye movement during the scan process leads to distortion, which limits the accuracy of quantitative measurements using 3D OCT data. In this paper, we present a novel software based method to correct motion artifacts in OCT raster scans. Motion compensation is performed retrospectively using image registration algorithms on the OCT data sets themselves. Multiple, successively acquired volume scans with orthogonal fast scan directions are registered retrospectively in order to estimate and correct eye motion. Registration is performed by optimizing a large scale numerical problem as given by a global objective function using one dense displacement field for each input volume and special regularization based on the time structure of the acquisition process. After optimization, each volume is undistorted and a single merged volume is constructed that has superior signal quality compared to the input volumes. Experiments were performed using 3D OCT data from the macula and optic nerve head acquired with a high-speed ultra-high resolution 850 nm spectral OCT as well as wide field data acquired with a 1050 nm swept source OCT instrument. Evaluation of registration performance and result stability as well as visual inspection shows that the algorithm can correct for motion in all three dimensions and on a per A-scan basis. Corrected volumes do not show visible motion artifacts. In addition, merging multiple motion corrected and registered volumes leads to improved signal quality. These results demonstrate that motion correction and merging improves image quality and should also improve morphometric measurement accuracy from volumetric OCT data.

  1. Parametric imaging of collagen structural changes in human osteoarthritic cartilage using optical polarization tractography

    Science.gov (United States)

    Ravanfar, Mohammadreza; Pfeiffer, Ferris M.; Bozynski, Chantelle C.; Wang, Yuanbo; Yao, Gang

    2017-12-01

    Collagen degeneration is an important pathological feature of osteoarthritis. The purpose of this study is to investigate whether the polarization-sensitive optical coherence tomography (PSOCT)-based optical polarization tractography (OPT) can be useful in imaging collagen structural changes in human osteoarthritic cartilage samples. OPT eliminated the banding artifacts in conventional PSOCT by calculating the depth-resolved local birefringence and fiber orientation. A close comparison between OPT and PSOCT showed that OPT provided improved visualization and characterization of the zonal structure in human cartilage. Experimental results obtained in this study also underlined the importance of knowing the collagen fiber orientation in conventional polarized light microscopy assessment. In addition, parametric OPT imaging was achieved by quantifying the surface roughness, birefringence, and fiber dispersion in the superficial zone of the cartilage. These quantitative parametric images provided complementary information on the structural changes in cartilage, which can be useful for a comprehensive evaluation of collagen damage in osteoarthritic cartilage.

  2. Control of Rotational Energy and Angular Momentum Orientation with an Optical Centrifuge

    Science.gov (United States)

    Ogden, Hannah M.; Murray, Matthew J.; Mullin, Amy S.

    2017-04-01

    We use an optical centrifuge to trap and spin molecules to an angular frequency of 30 THz with oriented angular momenta and extremely high rotational energy and then investigate their subsequent collision dynamics with transient high resolution IR spectroscopy. The optical centrifuge is formed by combining oppositely-chirped pulses of 800 nm light, and overlapping them spatially and temporally. Polarization-sensitive Doppler-broadened line profiles characterize the anisotropic kinetic energy release of the super rotor molecules, showing that they behave like molecular gyroscopes. Studies are reported for collisions of CO2 super rotors with CO2, He and Ar. These studies reveal how mass, velocity and rotational adiabaticity impact the angular momentum relaxation and reorientation. Quantum scattering calculations provide insight into the J-specific collision cross sections that control the relaxation. NSF-CHE 105 8721.

  3. Terahertz Quantum Cascade Laser Based 3D Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — LongWave Photonics proposes a terahertz quantum-cascade laser based swept-source optical coherence tomography (THz SS-OCT) system for single-sided, 3D,...

  4. Wide-band and fast wavelength-swept optical parametric oscillator with a photonic crystal fiber based on dispersion tuning technology at 1 μm

    Science.gov (United States)

    Chen, Jin; Yang, Sigang; Guo, Qiang; Chen, Hongwei; Chen, Minghua; Xie, Shizhong

    2016-03-01

    A wavelength-swept fiber optical parametric oscillator (FOPO) based on dispersion tuning technology at wavelength around 1 μm is demonstrated. A continuous wave single-longitudinal-mode ytterbium doped fiber laser with a line-width of 0.05 nm is modulated through a LiNbO3 Mach-Zehnder modulator to be a pulsed source with variable repetition rate. The pulsed source is amplified with a two-stage ytterbium doped fiber amplifier (YDFA) to a mediate power and a high power YDFA to peak power higher than 40 W. And a homemade 50-m photonic crystal fiber (PCF) which provides the optical parametric gain is pumped by the pulsed source. The optical modulator is driven by a frequency-swept electrical clock signal with frequency ranges from 107.24 MHz to 107.31 MHz. Thus the FOPO generates a wavelength-swept light source with a range of 80 nm centered at 1065.10 nm. Through careful customizing the sweeping rate of the driving clock signal, the sweeping rate of the parametric oscillator can be up to 10 kHz, which is limited by currently used electrical sweeping source. The generated pulses train are with pulse width of about 110 ps. For the electrical scan is used instead of the traditional mechanical scanning method in conventional wavelength-swept sources, it performs better stability under prolonged operation. The wavelength-swept FOPO is potential to be applied in OCT systems for its good stability and advantaged wavelength band.

  5. In-vivo cutaneous burn characterization and scar assay with multi-functional optical coherence tomography (Conference Presentation)

    Science.gov (United States)

    Kim, Bumju; Yoon, Yeorum; Le, Viet-Hoan; Yoon, Calvin J.; Kim, Ki Hean

    2016-03-01

    Research about the cutaneous burn was separated by assessment of burn depth and development of wound healing therapy. Various in vivo optical techniques were used to determined burn depth and observe the wound healing process. In this paper, we report the usage of multimodal optical coherence tomography system, which containing angiographic and polarization sensitive OCT (PS-OCT) with conventional OCT system, at burn studies. Burn was induced at 4 different degrees by control the attachment time of 75 Celsius degree heated brass rod at dorsal skin of the rat. For the burn depth assessment, we imaged the different burn degrees area. Changes of polarization sensitive signal were providing burn depth information. To see the wound healing process, each wound area imaged at long period. Conventional OCT shows the structural information about the tissue, like layer and hair follicle. Angiographic OCT provides vascular distribution and diameter of blood vessel information and PS-OCT shows birefringence tissue information. Based on the multimodal OCT data, burn depth assessment were well matched with burn induced time and wound healing process was consistent with previous wound healing report. Therefore, the multimodal OCT holds potential for burn study.

  6. Quantum optics

    National Research Council Canada - National Science Library

    Agarwal, G. S

    2013-01-01

    .... Focusing on applications of quantum optics, the textbook covers recent developments such as engineering of quantum states, quantum optics on a chip, nano-mechanical mirrors, quantum entanglement...

  7. Tri-band optical coherence tomography for lipid and vessel spectroscopic imaging

    Science.gov (United States)

    Yu, Luoqin; Kang, Jiqiang; Wang, Xie; Wei, Xiaoming; Chan, Kin-Tak; Lee, Nikki P.; Wong, Kenneth K. Y.

    2016-03-01

    Optical coherence tomography (OCT) has been utilized for various functional imaging applications. One of its highlights comes from spectroscopic imaging, which can simultaneously obtain both morphologic and spectroscopic information. Assisting diagnosis and therapeutic intervention of coronary artery disease is one of the major directions in spectroscopic OCT applications. Previously Tanaka et al. have developed a spectral domain OCT (SDOCT) to image lipid distribution within blood vessel [1]. In the meantime, Fleming et al. have demonstrated optical frequency domain imaging (OFDI) by a 1.3-μm swept source and quadratic discriminant analysis model [2]. However, these systems suffered from burdensome computation as the optical properties' variation was calculated from a single-band illumination that provided limited contrast. On the other hand, multi-band OCT facilitates contrast enhancement with separated wavelength bands, which further offers an easier way to distinguish different materials. Federici and Dubois [3] and Tsai and Chan [4] have demonstrated tri-band OCT systems to further enhance the image contrast. However, these previous work provided under-explored functional properties. Our group has reported a dual-band OCT system based on parametrically amplified Fourier domain mode-locked (FDML) laser with time multiplexing scheme [5] and a dual-band FDML laser OCT system with wavelength-division multiplexing [6]. Fiber optical parametric amplifier (OPA) can be ideally incorporated in multi-band spectroscopic OCT system as it has a broad amplification window and offers an additional output range at idler band, which is phase matched with the signal band. The sweeping ranges can thus overcome traditional wavelength bands that are limited by intra-cavity amplifiers in FDML lasers. Here, we combines the dual-band FDML laser together with fiber OPA, which consequently renders a simultaneous tri-band output at 1.3, 1.5, and 1.6 μm, for intravascular applications

  8. Optical Computing

    Indian Academy of Sciences (India)

    Optics has been used in computing for a number of years but the main emphasis has been and continues to be to link portions of computers, for communications, or more intrin- sically in devices that have some optical application or component (optical pattern recognition, etc). Optical digi- tal computers are still some years ...

  9. Repeatability and reproducibility of anterior chamber volume measurements using 3-dimensional corneal and anterior segment optical coherence tomography.

    Science.gov (United States)

    Fukuda, Shinichi; Kawana, Keisuke; Yasuno, Yoshiaki; Oshika, Tetsuro

    2011-03-01

    To evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements using swept-source 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT) and dual Scheimpflug imaging. Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan. Nonrandomized clinical trial. Measurements were taken in normal eyes (subject group) and in eyes with primary angle closure (PAC) (patient group). In the subject group, the entire ACV and the central 8.0 mm diameter ACV were measured using CAS-OCT and dual Scheimpflug imaging. In the patient group, the entire ACV and 8.0 mm ACV were measured using CAS-OCT. The coefficient of variation and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility, and the correlation between the 2 devices was assessed. In the subject group, the mean 8.0 mm ACV was 110.14 mm(3) ± 12.57 (SD) using CAS-OCT and 114.51 ± 14.69 mm(3) using Scheimpflug imaging; there was a significant linear correlation (r = 0.878, P ACV on CAS-OCT was 165.15 ± 29.29 mm(3). The ICCs of the 8.0 mm and entire ACV measurements were greater than 0.94. The coefficients of repeatability and reproducibility of the 8.0 mm ACV and entire ACV measurements were less than 5%. In the patient group, the 8.0 mm and entire ACV measurements showed good reproducibility and repeatability. The CAS-OCT method allowed noninvasive measurement of the entire ACV with sufficient repeatability and reproducibility. The 8.0 mm ACV measurements with CAS-OCT and Scheimpflug imaging were comparable. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Intrasurgical Human Retinal Imaging With Manual Instrument Tracking Using a Microscope-Integrated Spectral-Domain Optical Coherence Tomography Device.

    Science.gov (United States)

    Hahn, Paul; Carrasco-Zevallos, Oscar; Cunefare, David; Migacz, Justin; Farsiu, Sina; Izatt, Joseph A; Toth, Cynthia A

    2015-07-01

    To characterize the first in-human intraoperative imaging using a custom prototype spectral-domain microscope-integrated optical coherence tomography (MIOCT) device during vitreoretinal surgery with instruments in the eye. Under institutional review board approval for a prospective intraoperative study, MIOCT images were obtained at surgical pauses with instruments held static in the vitreous cavity and then concurrently with surgical maneuvers. Postoperatively, MIOCT images obtained at surgical pauses were compared with images obtained with a high-resolution handheld spectral-domain OCT (HHOCT) system with objective endpoints, including acquisition of images acceptable for analysis and identification of predefined macular morphologic or pathologic features. Human MIOCT images were successfully obtained before incision and during pauses in surgical maneuvers. MIOCT imaging confirmed preoperative diagnoses, such as epiretinal membrane, full-thickness macular hole, and vitreomacular traction and demonstrated successful achievement of surgical goals. MIOCT and HHOCT images obtained at surgical pauses in two cohorts of five patients were comparable with greater than or equal to 80% correlation in 80% of patients. Real-time video-imaging concurrent with surgical manipulations enabled, for the first time using this device, visualization of dynamic instrument-retina interaction with targeted OCT tracking. MIOCT is successful for imaging at surgical pauses and for real-time image guidance with implementation of targeted OCT tracking. Even faster acquisition speeds are currently being developed with incorporation of a swept-source MIOCT engine. Further refinements and investigations will be directed toward continued integration for real-time volumetric imaging of surgical maneuvers. Ongoing development of seamless MIOCT systems will likely transform surgical visualization, approaches, and decision-making.

  11. Engineering Optics

    CERN Document Server

    Iizuka, Keigo

    2008-01-01

    Engineering Optics is a book for students who want to apply their knowledge of optics to engineering problems, as well as for engineering students who want to acquire the basic principles of optics. It covers such important topics as optical signal processing, holography, tomography, holographic radars, fiber optical communication, electro- and acousto-optic devices, and integrated optics (including optical bistability). As a basis for understanding these topics, the first few chapters give easy-to-follow explanations of diffraction theory, Fourier transforms, and geometrical optics. Practical examples, such as the video disk, the Fresnel zone plate, and many more, appear throughout the text, together with numerous solved exercises. There is an entirely new section in this updated edition on 3-D imaging.

  12. Optical measurement of arterial mechanical properties: from atherosclerotic plaque initiation to rupture.

    Science.gov (United States)

    Nadkarni, Seemantini K

    2013-12-01

    During the pathogenesis of coronary atherosclerosis, from lesion initiation to rupture, arterial mechanical properties are altered by a number of cellular, molecular, and hemodynamic processes. There is growing recognition that mechanical factors may actively drive vascular cell signaling and regulate atherosclerosis disease progression. In advanced plaques, the mechanical properties of the atheroma influence stress distributions in the fibrous cap and mediate plaque rupture resulting in acute coronary events. This review paper explores current optical technologies that provide information on the mechanical properties of arterial tissue to advance our understanding of the mechanical factors involved in atherosclerosis development leading to plaque rupture. The optical approaches discussed include optical microrheology and traction force microscopy that probe the mechanical behavior of single cell and extracellular matrix components, and intravascular imaging modalities including laser speckle rheology, optical coherence elastography, and polarization-sensitive optical coherence tomography to measure the mechanical properties of advanced coronary lesions. Given the wealth of information that these techniques can provide, optical imaging modalities are poised to play an increasingly significant role in elucidating the mechanical aspects of coronary atherosclerosis in the future.

  13. Anisotropy of optical, electrical, and photoelectrical properties of amorphous hydrogenated silicon films modified by femtosecond laser irradiation

    Science.gov (United States)

    Amasev, D. V.; Khenkin, M. V.; Drevinskas, R.; Kazansky, P.; Kazanskii, A. G.

    2017-06-01

    Two types of independent anisotropic structures have been formed simultaneously in amorphous hydrogenated films by applying a femtosecond laser pulse to them, i.e., a structure with a period of several micrometers to several tens of micrometers and a structure with a period of several hundred nanometers. The formation mechanisms of these strictures are different, which allows us to orient them relative to each other in a desirable way. Both structures independently influence the optical properties of the modified films, which causes the diffraction of transmitted light and making the films polarization-sensitive. The conductivity of the modified films correlates with the mutual orientation of the anisotropic structures, whereas no interrelation between the photoconductivity and optical performance of the modified films has been observed.

  14. Circular polarization switching and bistability in an optically injected 1300 nm spin-vertical cavity surface emitting laser

    Energy Technology Data Exchange (ETDEWEB)

    Alharthi, S. S., E-mail: ssmalh@essex.ac.uk; Henning, I. D.; Adams, M. J. [School of Computer Science and Electronic Engineering, University of Essex, Wivenhoe Park, Colchester CO4 3SQ (United Kingdom); Hurtado, A. [School of Computer Science and Electronic Engineering, University of Essex, Wivenhoe Park, Colchester CO4 3SQ (United Kingdom); Institute of Photonics, Physics Department, University of Strathclyde, Wolfson Centre, 106 Rottenrow East, Glasgow G4 0NW, Scotland (United Kingdom); Korpijarvi, V.-M.; Guina, M. [Optoelectronics Research Centre (ORC), Tampere University of Technology, P.O. Box 692, FIN-33101 Tampere (Finland)

    2015-01-12

    We report the experimental observation of circular polarization switching (PS) and polarization bistability (PB) in a 1300 nm dilute nitride spin-vertical cavity surface emitting laser (VCSEL). We demonstrate that the circularly polarized optical signal at 1300 nm can gradually or abruptly switch the polarization ellipticity of the spin-VCSEL from right-to-left circular polarization and vice versa. Moreover, different forms of PS and PB between right- and left-circular polarizations are observed by controlling the injection strength and the initial wavelength detuning. These results obtained at the telecom wavelength of 1300 nm open the door for novel uses of spin-VCSELs in polarization sensitive applications in future optical systems.

  15. Applied optics

    International Nuclear Information System (INIS)

    Orszag, A.; Antonetti, A.

    1988-01-01

    The 1988 progress report, of the Applied Optics laboratory, of the (Polytechnic School, France), is presented. The optical fiber activities are focused on the development of an optical gyrometer, containing a resonance cavity. The following domains are included, in the research program: the infrared laser physics, the laser sources, the semiconductor physics, the multiple-photon ionization and the nonlinear optics. Investigations on the biomedical, the biological and biophysical domains are carried out. The published papers and the congress communications are listed [fr

  16. High performance polarization-independent Quantum Dot Semiconductor Optical Amplifier with 22 dB fiber to fiber gain using Mode Propagation Tuning without additional polarization controller

    Science.gov (United States)

    Farmani, Ali; Farhang, Mahmoud; Sheikhi, Mohammad H.

    2017-08-01

    A detailed numerical investigation of polarization-independent quantum dot InAs/GaAs semiconductor optical amplifier (PIQS) based on a technique called mode propagation tuning (MPT) without the need for the polarization controller (PC) is reported, which can solve the limitation caused by polarization sensitivity in a semiconductor optical amplifier (SOA). Our calculations show that by a suitable tuning of the thickness of the active layer, only the TE0 and TM0 modes can propagate. Moreover, the gain saturation behavior of this SOA was measured at 1.55 μ m and found to be polarization-independent (PI). At active layer thickness of 1.7 μ m, the confinement factor was 0.75 and 0.7 for TE0 and TM0 modes, respectively, which leads to a gain difference up to 0.1 dB. The rate equations of the QD-SOA were also solved and a fiber to fiber gain of 22 dB was obtained. Additionally, a numerical simulation is presented which shows that the residual gain ripple and polarization sensitivity are sufficiently reduced when residual facet reflectivities of the SOA are in the range below 10-4 . In addition, the full-width at half-maximum of the horizontal and vertical far-field patterns (FFPs) are measured as 30° × 30°. The proposed structure can be used for logical applications.

  17. Hamilton's Optics

    Indian Academy of Sciences (India)

    IAS Admin

    Hamiton, optics, wavefronts, characterisic function, conical refraction. . Hamilton's Optics. The Power of Wavefronts. Rajaram Nityananada. Building on work by Fermat and Huygens, Hamil- ton transformed the study of geometrical optics in his very first paper, presented when still in his teens. His 'characteristic function' was ...

  18. Nonlinear optics

    CERN Document Server

    Boyd, Robert W

    2013-01-01

    Nonlinear Optics is an advanced textbook for courses dealing with nonlinear optics, quantum electronics, laser physics, contemporary and quantum optics, and electrooptics. Its pedagogical emphasis is on fundamentals rather than particular, transitory applications. As a result, this textbook will have lasting appeal to a wide audience of electrical engineering, physics, and optics students, as well as those in related fields such as materials science and chemistry.Key Features* The origin of optical nonlinearities, including dependence on the polarization of light* A detailed treatment of the q

  19. Optical fibres

    CERN Document Server

    Geisler, J; Boutruche, J P

    1986-01-01

    Optical Fibers covers numerous research works on the significant advances in optical fibers, with particular emphasis on their application.This text is composed of three parts encompassing 15 chapters. The first part deals with the manufacture of optical fibers and the materials used in their production. The second part describes optical-fiber connectors, terminals and branches. The third part is concerned with the major optoelectronic components encountered in optical-communication systems.This book will be of value to research scientists, engineers, and patent workers.

  20. Optical interconnects

    CERN Document Server

    Chen, Ray T

    2006-01-01

    This book describes fully embedded board level optical interconnect in detail including the fabrication of the thin-film VCSEL array, its characterization, thermal management, the fabrication of optical interconnection layer, and the integration of devices on a flexible waveguide film. All the optical components are buried within electrical PCB layers in a fully embedded board level optical interconnect. Therefore, we can save foot prints on the top real estate of the PCB and relieve packaging difficulty reduced by separating fabrication processes. To realize fully embedded board level optical

  1. Atom optics

    International Nuclear Information System (INIS)

    Balykin, V. I.; Jhe, W.

    1999-01-01

    Atom optics, in analogy to neutron and electron optics, deals with the realization of as a traditional elements, such as lenes, mirrors, beam splitters and atom interferometers, as well as a new 'dissipative' elements such as a slower and a cooler, which have no analogy in an another types of optics. Atom optics made the development of atom interferometer with high sensitivity for measurement of acceleration and rotational possible. The practical interest in atom optics lies in the opportunities to create atom microprobe with atom-size resolution and minimum damage of investigated objects. (Cho, G. S.)

  2. Electro-optical switching of liquid crystals of graphene oxide

    Science.gov (United States)

    Song, Jang-Kun

    Electric field effects on aqueous graphene-oxide (GO) dispersions are reviewed in this chapter. In isotropic and biphasic regimes of GO dispersions, in which the inter-particle friction is low, GO particles sensitively respond to the application of electric field, producing field-induced optical birefringence. The electro-optical sensitivity dramatically decreases as the phase transits to the nematic phase; the increasing inter-particle friction hinders the rotational switching of GO particles. The corresponding Kerr coefficient reaches the maximum near the isotropic to biphasic transition concentration, at which the Kerr coefficient is found be c.a. 1:8 · 10-5 mV-2, the highest value ever reported in all Kerr materials. The exceptionally large Kerr effect arises from the Maxwell- Wagner polarization of GO particles with an extremely large aspect ratio and a thick electrical double layer (EDL). The polarization sensitively depends on the ratio of surface and bulk conductivities in dispersions. As a result, low ion concentration in bulk solvent is highly required to achieve a quality electro-optical switching in GO dispersions. Spontaneous vinylogous carboxylic reaction in GO particles produces H+ ions, resulting in spontaneous degradation of electro-optical response with time, hence the removal of residual ions by using a centrifuge cleaning process significantly improves the electro-optical sensitivity. GO particle size is another important parameter for the Kerr coefficient and the response time. The best performance is observed in a GO dispersion with c.a. 0.5 μm mean size. Dielectrophoretic migration of GO particles can be also used to manipulate GO particles in solution. Using these unique features of GO dispersions, one can fabricate GO liquid crystal devices similar to conventional liquid crystal displays; the large Kerr effect allows fabricating a low power device working at extremely low electric fields.

  3. Applied optics and optical design

    CERN Document Server

    Conrady, Alexander Eugen

    1957-01-01

    ""For the optical engineer it is an indispensable work."" - Journal, Optical Society of America""As a practical guide this book has no rival."" - Transactions, Optical Society""A noteworthy contribution,"" - Nature (London)Part I covers all ordinary ray-tracing methods, together with the complete theory of primary aberrations and as much of higher aberration as is needed for the design of telescopes, low-power microscopes and simple optical systems. Chapters: Fundamental Equations, Spherical Aberration, Physical Aspect of Optical Images, Chromatic Aberration, Design of Achromatic Object-Glass

  4. Optics Express

    OpenAIRE

    Poon, Ting-Chung; Doh, K. B.

    2007-01-01

    The Hilbert transform as been investigated abundantly in coherent imaging. To the best of our knowledge, it is for the first time investigated in the context of incoherent imaging. We present a two-pupil optical heterodyne scanning system and analyze mathematically the design of its two pupils such that the optical system can perform the Hilbert transform on incoherent objects. Computer simulations of the idea clarify the theoretical results. (c) 2007 Optical Society of America.

  5. Optical electronics

    CERN Document Server

    Yariv, Amnon

    1991-01-01

    This classic text introduces engineering students to the first principles of major phenomena and devices of optoelectronics and optical communication technology. Yariv's "first principles" approach employs real-life examples and extensive problems. The text includes separate chapters on quantum well and semiconductor lasers, as well as phase conjugation and its applications. Optical fiber amplification, signal and noise considerations in optical fiber systems, laser arrays and distributed feedback lasers all are covered extensively in major sections within chapters.

  6. Rotationally acquired 4D-optical coherence tomography of embryonic chick hearts using retrospective gating on the common central A-scan

    DEFF Research Database (Denmark)

    Thommes, Jan; Happel, Christoph M.; Thrane, Lars

    2010-01-01

    input data are based on image similarity of adjacent pictures and a perpendicularly recorded B-scan or a repetitive low-resolution 3D-volume-scan. In our study, we introduce a novel technique that uses a rotational scan mode of a swept-source OCT system (Thorlabs) for imaging the beating embryonic heart...

  7. A comparison study of Riboflavin/UV-A and Rose-Bengal/Green light cross-linking of the rabbit corneas using optical coherence elastography

    Science.gov (United States)

    Li, Jiasong; Singh, Manmohan; Han, Zhaolong; Vantipalli, Srilatha; Liu, Chih-Hao; Wu, Chen; Raghunathan, Raksha; Kazemi, Tina; Twa, Michael D.; Larin, Kirill V.

    2016-03-01

    The biomechanical properties of the cornea are critical factors which determine its health and subsequent visual acuity. Keratoconus is a structural degeneration of the cornea which can diminish vision quality. Riboflavin/UV-A corneal collagen cross-linking (UV-CXL) is an emerging treatment that increases the stiffness of the cornea and improves its ability to resist further degeneration. While UV-CXL has shown great promise for effective therapy of the keratoconus, there are concerns associated with the UV irradiation, such as keratocyte cytotoxicity. Rose-bengal/green light corneal collagen cross-linking (RGX) has been proposed as an alternative to UV-CXL. Because of the high absorbance of the rose-bengal dye at green wavelengths, the treatment time is significantly shorter than with UV-CXL. Moreover, because green light is used in lieu of UV irradiation, there are no cytotoxic side-effects. In this study, noncontact optical coherence elastography (OCE) was used to compare the outcomes of UV-CXL and RGX treatment in rabbit cornea. Low-amplitude (micrometer scale) elastic waves were induced by a focused air-pulse loading system. The elastic wave propagation was then imaged by a phase-stabilized swept source OCE (PhS-SSOCE) system. The changes in the viscoelasticity of the corneas were quantified by a previously developed modified Rayleigh Lamb frequency model. The depth-resolved micro-scale phase-velocity distribution in the cornea was used to reveal the depth-wise heterogeneity before and after both cross-linking techniques. Our results show that UV-CXL and RGX increased the stiffness of the corneas by ~54% and ~5% while reducing the viscosity by ~42% and ~17%, respectively. The depth-wise phase velocities showed that UV-CXL affected the anterior ~1/3 of the corneas, while RGX only affected the anterior ~1/7 of the corneas.

  8. Optical Computing With Nonlinear Optics

    Science.gov (United States)

    Khitrova, Galina; Gibbs, Hyatt; Peyghambarian, Nasser

    1987-01-01

    Nonlinear optics is becoming a new thrust in the field of optical computing and signal processing.14 Optical nonlinearity makes the device's transmission intensity dependent, so one can obtain the thresholding needed for logic decisionmaking. Thresholding is essential to digital optical computing, neural nets, and associative memories. GaAs etalons exhibit many of the characteristics desirable for the nonlinear devices including high speed (picosecond) and diode-laser compatability. However, demonstrations of the use of nonlinear decisionmaking for optical computing have used ZnS or ZnSe interference filters. They are slow (millisecond), but they can be used with the visible 514.5-nm output of an argon laser. We have used such filters to demonstrate all-optical logic operations, one-bit addition by symbolic substitution, and recognition of a three-spot pattern in an arbitrary 2 x 8 array of input beams. The application to associative memories is under study.

  9. Polarization Optics

    OpenAIRE

    Fressengeas, Nicolas

    2010-01-01

    The physics of polarization optics *Polarized light propagation *Partially polarized light; DEA; After a brief introduction to polarization optics, this lecture reviews the basic formalisms for dealing with it: Jones Calculus for totally polarized light and Stokes parameters associated to Mueller Calculus for partially polarized light.

  10. Optical Computing

    Indian Academy of Sciences (India)

    Integration (VLSI) technology with smaller device dimensions and greater complexity. The smallest .... on a chip, much less than what was mentioned earlier (optical integration is still in its infancy compared to electronics). ..... Optical tunnel devices are under continuous development varying from small caliber endoscopes to ...

  11. Optical Computing

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 8; Issue 6. Optical Computing - Optical Components and Storage Systems. Debabrata Goswami. General Article Volume 8 Issue 6 June 2003 pp 56-71. Fulltext. Click here to view fulltext PDF. Permanent link:

  12. Assessment of Optical Coherence Tomography Imaging in the Diagnosis of Non-Melanoma Skin Cancer and Benign Lesions Versus Normal Skin:

    DEFF Research Database (Denmark)

    Mogensen, Mette; Jørgensen, Thomas Martini; Nürnberg, Birgit Meincke

    2009-01-01

    BACKGROUND Optical coherence tomography (OCT) is an optical imaging technique that may be useful in diagnosis of non-melanoma skin cancer (NMSC). OBJECTIVES To describe OCT features in NMSC such as actinic keratosis (AK) and basal cell carcinoma (BCC) and in benign lesions and to assess...... the diagnostic accuracy of OCT in differentiating NMSC from benign lesions and normal skin. METHODS AND MATERIALS OCT and polarization-sensitive (PS) OCT from 104 patients were studied. Observer-blinded evaluation of OCT images from 64 BCCs, 1 baso-squamous carcinoma, 39 AKs, two malignant melanomas, nine benign...... lesions, and 105 OCT images from perilesional skin was performed; 50 OCT images of NMSC and 50 PS-OCT images of normal skin were evaluated twice. RESULTS Sensitivity was 79% to 94% and specificity 85% to 96% in differentiating normal skin from lesions. Important features were absence of well...

  13. Generation and optimization of superpixels as image processing kernels for Jones matrix optical coherence tomography.

    Science.gov (United States)

    Miyazawa, Arata; Hong, Young-Joo; Makita, Shuichi; Kasaragod, Deepa; Yasuno, Yoshiaki

    2017-10-01

    Jones matrix-based polarization sensitive optical coherence tomography (JM-OCT) simultaneously measures optical intensity, birefringence, degree of polarization uniformity, and OCT angiography. The statistics of the optical features in a local region, such as the local mean of the OCT intensity, are frequently used for image processing and the quantitative analysis of JM-OCT. Conventionally, local statistics have been computed with fixed-size rectangular kernels. However, this results in a trade-off between image sharpness and statistical accuracy. We introduce a superpixel method to JM-OCT for generating the flexible kernels of local statistics. A superpixel is a cluster of image pixels that is formed by the pixels' spatial and signal value proximities. An algorithm for superpixel generation specialized for JM-OCT and its optimization methods are presented in this paper. The spatial proximity is in two-dimensional cross-sectional space and the signal values are the four optical features. Hence, the superpixel method is a six-dimensional clustering technique for JM-OCT pixels. The performance of the JM-OCT superpixels and its optimization methods are evaluated in detail using JM-OCT datasets of posterior eyes. The superpixels were found to well preserve tissue structures, such as layer structures, sclera, vessels, and retinal pigment epithelium. And hence, they are more suitable for local statistics kernels than conventional uniform rectangular kernels.

  14. Optical biosensors.

    Science.gov (United States)

    Damborský, Pavel; Švitel, Juraj; Katrlík, Jaroslav

    2016-06-30

    Optical biosensors represent the most common type of biosensor. Here we provide a brief classification, a description of underlying principles of operation and their bioanalytical applications. The main focus is placed on the most widely used optical biosensors which are surface plasmon resonance (SPR)-based biosensors including SPR imaging and localized SPR. In addition, other optical biosensor systems are described, such as evanescent wave fluorescence and bioluminescent optical fibre biosensors, as well as interferometric, ellipsometric and reflectometric interference spectroscopy and surface-enhanced Raman scattering biosensors. The optical biosensors discussed here allow the sensitive and selective detection of a wide range of analytes including viruses, toxins, drugs, antibodies, tumour biomarkers and tumour cells. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  15. Fiber optic coupled optical sensor

    Science.gov (United States)

    Fleming, Kevin J.

    2001-01-01

    A displacement sensor includes a first optical fiber for radiating light to a target, and a second optical fiber for receiving light from the target. The end of the first fiber is adjacent and not axially aligned with the second fiber end. A lens focuses light from the first fiber onto the target and light from the target onto the second fiber.

  16. Nonlinear optics

    CERN Document Server

    Bloembergen, Nicolaas

    1996-01-01

    Nicolaas Bloembergen, recipient of the Nobel Prize for Physics (1981), wrote Nonlinear Optics in 1964, when the field of nonlinear optics was only three years old. The available literature has since grown by at least three orders of magnitude.The vitality of Nonlinear Optics is evident from the still-growing number of scientists and engineers engaged in the study of new nonlinear phenomena and in the development of new nonlinear devices in the field of opto-electronics. This monograph should be helpful in providing a historical introduction and a general background of basic ideas both for expe

  17. Assessment of Ductile, Brittle, and Fatigue Fractures of Metals Using Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Gheorghe Hutiu

    2018-02-01

    Full Text Available Some forensic in situ investigations, such as those needed in transportation (for aviation, maritime, road, or rail accidents or for parts working under harsh conditions (e.g., pipes or turbines would benefit from a method/technique that distinguishes ductile from brittle fractures of metals—as material defects are one of the potential causes of incidents. Nowadays, the gold standard in material studies is represented by scanning electron microscopy (SEM. However, SEM instruments are large, expensive, time-consuming, and lab-based; hence, in situ measurements are impossible. To tackle these issues, we propose as an alternative, lower-cost, sufficiently high-resolution technique, Optical Coherence Tomography (OCT to perform fracture analysis by obtaining the topography of metallic surfaces. Several metals have been considered in this study: low soft carbon steels, lamellar graphite cast iron, an antifriction alloy, high-quality rolled steel, stainless steel, and ductile cast iron. An in-house developed Swept Source (SS OCT system, Master-Slave (MS enhanced is used, and height profiles of the samples’ surfaces were generated. Two configurations were used: one where the dimension of the voxel was 1000 μm3 and a second one of 160 μm3—with a 10 μm and a 4 μm transversal resolution, respectively. These height profiles allowed for concluding that the carbon steel samples were subject to ductile fracture, while the cast iron and antifriction alloy samples were subjected to brittle fracture. The validation of OCT images has been made with SEM images obtained with a 4 nm resolution. Although the OCT images are of a much lower resolution than the SEM ones, we demonstrate that they are sufficiently good to obtain clear images of the grains of the metallic materials and thus to distinguish between ductile and brittle fractures—especially with the higher resolution MS/SS-OCT system. The investigation is finally extended to the most useful case of

  18. Anomalous amplified and bound-state-like optical transmissions via unidirectional interaction in parity-time symmetric metamaterials

    Science.gov (United States)

    Zhang, Yan-Rong; Wang, Wei; Wang, Lu-Qi; Guo, Rui-Peng; Cao, Xuewei; Chen, Jing

    2018-03-01

    We develop a coupled-mode theory on the optical transmission in parity-time ( P T ) symmetric coaxial metamaterials. Modeled by coupled lossy Lorentzian oscillators, the theory provides a good fit to numerical full-wave simulation. In the scenario of unidirectional coupling, two polarization-sensitive anomalies are obtained: an amplified transmission and an ultra-narrow one analogous to bound states in continuum. We argue that these phenomena are associated with either a unidirectional-field-transfer process or an indirect unidirectional-field-trapping resonance. The broadening effect is shown to determine the magnitude and polarization of the transmission. Our theory and analysis provide a deep understanding on the importance of P T symmetry and dark helical modes and would contribute to applications such as light storage, field amplification, and even lasing.

  19. Integrated optics

    International Nuclear Information System (INIS)

    Jekowski, J.; Aeby, I.

    1979-01-01

    The purpose of the R and D effort is to establish a baseline technology in integrated optic techniques within the EMG. Significant investment presently being made by industry in this area indicates that this technology may offer an alternative solution for high speed digital data acquisition and transmission. The objectives of this year's integrated optics program were three-fold: (1) to establish a literature search and maintain industry contacts in an attempt to make the needs of the Weapons Test Program known; (2) to assist the Las Vegas Hybrid facility in establising integrated optic fabrication techniques for their new Thin Film Laboratory; and (3) to conduct basic experiments at Los Alamos in the construction of photolithograhicaly etched plastic film devices. The report describes the successful completion of preliminary investigations into photolithographic techniques and continuing investigations into newly announced integrated optic techniques and devices that would be applicable to the weapons test program

  20. Optical Spectroscopy

    DEFF Research Database (Denmark)

    Thyrhaug, Erling

    The work presented in this thesis is broadly concerned with how complexation reactions and molecular motion can be characterized with the standard techniques in optical spectroscopy. The thesis aims to show a relatively broad range of methods for probing physico-chemical properties in fluorophore...... containing systems and are characterized using techniques in optical spectroscopy. Of the standard techniques in optical spectroscopy, particular attention has been paid to those based on time-resolved measurements and polarization, which is reflected in the experiment design in the projects. Not all...... reactions by optical spectroscopy. In project 1 simple steady-state absorption and fluorescence spectroscopy is used to determine the stoichiometries and equilibrium constants in the inclusion complex formation between cyclodextrins and derivatives of the water-insoluble oligo(phenylene vinylene) in aqueous...

  1. Quantum optics

    DEFF Research Database (Denmark)

    Andersen, Ulrik Lund

    2013-01-01

    Further sensitivity improvements are required before advanced optical interferometers will be able to measure gravitational waves. A team has now shown that introducing quantum squeezing of light may help to detect these elusive waves.......Further sensitivity improvements are required before advanced optical interferometers will be able to measure gravitational waves. A team has now shown that introducing quantum squeezing of light may help to detect these elusive waves....

  2. Ocean optics

    Energy Technology Data Exchange (ETDEWEB)

    Spinard, R.W.; Carder, K.L.; Perry, M.J.

    1994-12-31

    This volume is the twenty fifth in the series of Oxford Monographs in Geology and Geophysics. The propagation off light in the hydra-atmosphere systems is governed by the integral-differential Radiative Transfer Equation (RTE). Closure and inversion are the most common techniques in optical oceanography to understand the most basic principles of natural variability. Three types of closure are dealt with: scale closure, experimental closure, and instrument closure. The subject is well introduced by Spinard et al. in the Preface while Howard Gordon in Chapter 1 provides an in-depth introduction to the RTE and its inherent problems. Inherent and apparent optical properties are dealt with in Chapter 2 by John Kirk and the realities of optical closure are presented in the following chapter by Ronald Zaneveld. The balance of the papers in this volume is quite varied. The early papers deal in a very mathematical manner with the basics of radiative transfer and the relationship between inherent and optical properties. Polarization of sea water is discussed in a chapter that contains a chronological listing of discoveries in polarization, starting at about 1000 AD with the discovery of dichroic properties of crystals by the Vikings and ending with the demonstration of polarotaxis in certain marine organisms by Waterman in 1972. Chapter 12 on Raman scattering in pure water and the pattern recognition techniques presented in Chapter 13 on the optical effects of large particles may be of relevance to fields outside ocean optics.

  3. QUANTUM OPTICS. Universal linear optics.

    Science.gov (United States)

    Carolan, Jacques; Harrold, Christopher; Sparrow, Chris; Martín-López, Enrique; Russell, Nicholas J; Silverstone, Joshua W; Shadbolt, Peter J; Matsuda, Nobuyuki; Oguma, Manabu; Itoh, Mikitaka; Marshall, Graham D; Thompson, Mark G; Matthews, Jonathan C F; Hashimoto, Toshikazu; O'Brien, Jeremy L; Laing, Anthony

    2015-08-14

    Linear optics underpins fundamental tests of quantum mechanics and quantum technologies. We demonstrate a single reprogrammable optical circuit that is sufficient to implement all possible linear optical protocols up to the size of that circuit. Our six-mode universal system consists of a cascade of 15 Mach-Zehnder interferometers with 30 thermo-optic phase shifters integrated into a single photonic chip that is electrically and optically interfaced for arbitrary setting of all phase shifters, input of up to six photons, and their measurement with a 12-single-photon detector system. We programmed this system to implement heralded quantum logic and entangling gates, boson sampling with verification tests, and six-dimensional complex Hadamards. We implemented 100 Haar random unitaries with an average fidelity of 0.999 ± 0.001. Our system can be rapidly reprogrammed to implement these and any other linear optical protocol, pointing the way to applications across fundamental science and quantum technologies. Copyright © 2015, American Association for the Advancement of Science.

  4. Semiconductor Optics

    CERN Document Server

    Klingshirn, Claus F

    2012-01-01

    This updated and enlarged new edition of Semiconductor Optics provides an introduction to and an overview of semiconductor optics from the IR through the visible to the UV, including linear and nonlinear optical properties, dynamics, magneto and electrooptics, high-excitation effects and laser processes, some applications, experimental techniques and group theory. The mathematics is kept as elementary as possible, sufficient for an intuitive understanding of the experimental results and techniques treated. The subjects covered extend from physics to materials science and optoelectronics. Significantly updated chapters add coverage of current topics such as electron hole plasma, Bose condensation of excitons and meta materials. Over 120 problems, chapter introductions and a detailed index make it the key textbook for graduate students in physics. The mathematics is kept as elementary as possible, sufficient for an intuitive understanding of the experimental results and techniques treated. The subjects covered ...

  5. Optical memory

    Science.gov (United States)

    Mao, Samuel S; Zhang, Yanfeng

    2013-07-02

    Optical memory comprising: a semiconductor wire, a first electrode, a second electrode, a light source, a means for producing a first voltage at the first electrode, a means for producing a second voltage at the second electrode, and a means for determining the presence of an electrical voltage across the first electrode and the second electrode exceeding a predefined voltage. The first voltage, preferably less than 0 volts, different from said second voltage. The semiconductor wire is optically transparent and has a bandgap less than the energy produced by the light source. The light source is optically connected to the semiconductor wire. The first electrode and the second electrode are electrically insulated from each other and said semiconductor wire.

  6. Reflective optics

    CERN Document Server

    Korsch, Dietrich

    1991-01-01

    This is the first book dedicated exclusively to all-reflective imaging systems. It is a teaching tool as well as a practical design tool for anyone who specializes in optics, particularly for those interested in telescopes, infrared, and grazing-incidence systems. The first part of the book describes a unified geometric optical theory of all-reflective imaging systems (from near-normal to grazing incidence) developed from basic principles. The second part discusses correction methods and a multitude of closed-form solutions of well-corrected systems, supplemented with many conventional and unc

  7. Optical dosimeter

    International Nuclear Information System (INIS)

    Drukaroff, I.; Fishman, R.

    1984-01-01

    A reflecting optical dosimeter is a thin block of optical material having an input light pipe at one corner and an output light pipe at another corner, arranged so that the light path includes several reflections off the edges of the block to thereby greatly extend its length. In a preferred embodiment, one corner of the block is formed at an angle so that after the light is reflected several times between two opposite edges, it is then reflected several more times between the other two edges

  8. Statistical optics

    CERN Document Server

    Goodman, Joseph W

    2015-01-01

    This book discusses statistical methods that are useful for treating problems in modern optics, and the application of these methods to solving a variety of such problems This book covers a variety of statistical problems in optics, including both theory and applications.  The text covers the necessary background in statistics, statistical properties of light waves of various types, the theory of partial coherence and its applications, imaging with partially coherent light, atmospheric degradations of images, and noise limitations in the detection of light. New topics have been introduced i

  9. Quantum optics

    International Nuclear Information System (INIS)

    Flytzanis, C.

    1988-01-01

    The 1988 progress report of the Quantum Optics laboratory (Polytechnic School, France) is presented. The research program is focused on the behavior of dense and dilute materials submitted to short and high-intensity light radiation fields. Nonlinear optics techniques, with time and spatial resolution, are developed. An important research activity concerns the investigations on the interactions between the photon beams and the inhomogeneous or composite materials, as well as the artificial microstructures. In the processes involving molecular beams and surfaces, the research works on the photophysics of surfaces and the molecule-surface interactions, are included [fr

  10. Diophantine Optics

    Science.gov (United States)

    Rouan, D.

    2016-09-01

    What I call Diophantine optics is the exploitation in optics of some remarkable algebraic relations between powers of integers. The name comes from Diophantus of Alexandria, a greek mathematician, known as the father of algebra. He studied polynomial equations with integer coefficients and integer solutions, called diophantine equations. Since constructive or destructive interferences are playing with optical path differences which are multiple integer (odd or even) of λ/2 and that the complex amplitude is a highly non-linear function of the optical path difference (or equivalently of the phase), one can understand that any Taylor development of this amplitude implies powers of integers. This is the link with Diophantine equations. We show how, especially in the field of interferometry, remarkable relations between powers of integers can help to solve several problems, such as achromatization of a phase shifter or deep nulling efficiency. It appears that all the research that was conducted in this frame of thinking, relates to the field of detection of exoplanets, a very active domain of astrophysics today.

  11. Optical profilometer

    Science.gov (United States)

    Wieloszyńska, Aleksandra; StrÄ kowski, Marcin

    2016-09-01

    The profilometry plays a huge role in the most fields of science and technology. It allows to measure the profile of the surface with high-resolution. This technique is used in the fields like optic, electronic, medicine, automotive, and much more. The aim of the current work was to design and build optical profilometer based on the interference phenomena. The developed device has been working with He-Ne laser (632.8 nm). The optical parts have been chosen in order to reach the sized 2.0 mm x 1.6 mm of scanning area. The setup of the profilometer is based on Twyman-Green interferometer. Therefore, the phase distribution of the backreflected light from measured surface is recorded. The measurements are carried out with the aid of multiframe algorithms. In this approach we have used the Hariharan algorithm to obtain the exact value of the recorded phase. During tests, which have been carried out in order to check the functionality of the device, the interference patterns have been recoded and processed in order to obtain the 3D profile of measured surface. In this contribution the setup of the optical system, as well as signal processing methods are going to be presented. The brief discussion about the advantages and disadvantages, and usefulness of this approach will be carried out.

  12. Optical fibres

    CERN Multimedia

    1992-01-01

    These optical fibres are used to detect particles passing through in bunches. Made from scintillating material, the fibres glow when a high energy particle passes through them. These detectors are known as spaghetti detectors and are used to measure the energy of particles.

  13. Optical geometry

    International Nuclear Information System (INIS)

    Robinson, I.; Trautman, A.

    1988-01-01

    The geometry of classical physics is Lorentzian; but weaker geometries are often more appropriate: null geodesics and electromagnetic fields, for example, are well known to be objects of conformal geometry. To deal with a single null congruence, or with the radiative electromagnetic fields associated with it, even less is needed: flag geometry for the first, optical geometry, with which this paper is chiefly concerned, for the second. The authors establish a natural one-to-one correspondence between optical geometries, considered locally, and three-dimensional Cauchy-Riemann structures. A number of Lorentzian geometries are shown to be equivalent from the optical point of view. For example the Goedel universe, the Taub-NUT metric and Hauser's twisting null solution have an optical geometry isomorphic to the one underlying the Robinson congruence in Minkowski space. The authors present general results on the problem of lifting a CR structure to a Lorentz manifold and, in particular, to Minkowski space; and exhibit the relevance of the deviation form to this problem

  14. Optical twisters

    DEFF Research Database (Denmark)

    Daria, Vincent R.; Palima, Darwin; Glückstad, Jesper

    2010-01-01

    We describe a diffracting beam with orbital angular momentum (OAM) but with a helical profile in both phase and amplitude components of the beam. This is different from Laguerre-Gaussian (LG) beams where only the phase component has a helical profile. Such profile in LG beams introduces a phase s....... Such beams can be applied to fundamental studies of light and atoms such as in quantum entanglement of the OAM, toroidal traps for cold atoms and for optical manipulation of microscopic particles....... and linearly scaled towards no phase singularity at the centre of the beam. At the focal volume, we show that our beam forms an intensity distribution that can be accurately described as an "optical twister" as it propagates in the forward direction. Unlike LG beams, an optical twister can have minimal changes...... in radius but with a scalable OAM. Furthermore, we characterize the OAM in terms of its capacity to introduce spiral motion on particles trapped along its orbit. We also show that our "optical twister" maintains a high concentration of photons at the focus even as the topological charge is increased...

  15. Skin optics

    NARCIS (Netherlands)

    van Gemert, M. J.; Jacques, S. L.; Sterenborg, H. J.; Star, W. M.

    1989-01-01

    Quantitative dosimetry in the treatment of skin disorders with (laser) light requires information on propagation of light in the skin related to the optical properties of the individual skin layers. This involves the solution of the integro-differential equation of radiative transfer in a model

  16. Optical metrology

    CERN Document Server

    Gåsvik, Kjell J

    2003-01-01

    New material on computerized optical processes, computerized ray tracing, and the fast Fourier transform, Bibre-Bragg sensors, and temporal phase unwrapping.* New introductory sections to all chapters.* Detailed discussion on lasers and laser principles, including an introduction to radiometry and photometry.* Thorough coverage of the CCD camera.

  17. Optical Computing

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 8; Issue 7. Optical Computing - Research Trends. Debabrata Goswami. General Article Volume 8 Issue 7 July 2003 pp 8-21. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/008/07/0008-0021. Keywords.

  18. Optical Coherence and Quantum Optics

    CERN Document Server

    Mandel, Leonard

    1995-01-01

    This book presents a systematic account of optical coherence theory within the framework of classical optics, as applied to such topics as radiation from sources of different states of coherence, foundations of radiometry, effects of source coherence on the spectra of radiated fields, coherence theory of laser modes, and scattering of partially coherent light by random media. The book starts with a full mathematical introduction to the subject area and each chapter concludes with a set of exercises. The authors are renowned scientists and have made substantial contributions to many of the topi

  19. Optical Magnetometry

    Science.gov (United States)

    Budker, Dmitry; Kimball, Derek F. Jackson

    2013-03-01

    Part I. Principles and Techniques: 1. General principles and characteristics of optical magnetometers D. F. Jackson Kimball, E. B. Alexandrov and D. Budker; 2. Quantum noise in atomic magnetometers M. V. Romalis; 3. Quantum noise, squeezing, and entanglement in radio-frequency optical magnetometers K. Jensen and E. S. Polzik; 4. Mx and Mz magnetometers E. B. Alexandrov and A. K. Vershovskiy; 5. Spin-exchange-relaxation-free (serf) magnetometers I. Savukov and S. J. Seltzer; 6. Optical magnetometry with modulated light D. F. Jackson Kimball, S. Pustelny, V. V. Yashchuk and D. Budker; 7. Microfabricated atomic magnetometers S. Knappe and J. Kitching; 8. Optical magnetometry with nitrogen-vacancy centers in diamond V. M. Acosta, D. Budker, P. R. Hemmer, J. R. Maze and R. L. Walsworth; 9. Magnetometry with cold atoms W. Gawlik and J. M. Higbie; 10. Helium magnetometers R. E. Slocum, D. D. McGregor and A. W. Brown; 11. Surface coatings for atomic magnetometry S. J. Seltzer, M.-A. Bouchiat and M. V. Balabas; 12. Magnetic shielding V. V. Yashchuk, S.-K. Lee and E. Paperno; Part II. Applications: 13. Remote detection magnetometry S. M. Rochester, J. M. Higbie, B. Patton, D. Budker, R. Holzlöhner and D. Bonaccini Calia; 14. Detection of nuclear magnetic resonance with atomic magnetometers M. P. Ledbetter, I. Savukov, S. J. Seltzer and D. Budker; 15. Space magnetometry B. Patton, A. W. Brown, R. E. Slocum and E. J. Smith; 16. Detection of biomagnetic fields A. Ben-Amar Baranga, T. G. Walker and R. T. Wakai; 17. Geophysical applications M. D. Prouty, R. Johnson, I. Hrvoic and A. K. Vershovskiy; Part III. Broader Impact: 18. Tests of fundamental physics with optical magnetometers D. F. Jackson Kimball, S. K. Lamoreaux and T. E. Chupp; 19. Nuclear magnetic resonance gyroscopes E. A. Donley and J. Kitching; 20. Commercial magnetometers and their application D. C. Hovde, M. D. Prouty, I. Hrvoic and R. E. Slocum; Index.

  20. Compensation of spectral artifacts in dual-modality intravascular optical coherence tomography and near-infrared spectroscopy (Conference Presentation)

    Science.gov (United States)

    Fard, Ali M.; Gardecki, Joseph A.; Ughi, Giovanni J.; Hyun, Chulho; Tearney, Guillermo J.

    2016-02-01

    findings are therefore crucial for the practical application and clinical translation of dual-modality intravascular OCT-NIRS imaging when the same swept sources are used for both OCT and spectroscopy.

  1. Optical and histological evaluation in human tendon tissue sterilized by ionizing radiation

    International Nuclear Information System (INIS)

    Funari, Ana Paula; Antebi, Uri; Santos, Luiz Augusto; Vieira, Daniel Perez; Miranda, Jurandir Tomaz de; Alves, Nelson Mendes; Freitas, Anderson Zanardi de; Mathor, Monica Beatriz

    2017-01-01

    Sterilization by irradiation is a technique that is used by tissue banks aiming to eliminate contamination of human allografts, being a safe method, free of residue and used as final sterilization. After the tissue procurement, these undergo a series of processing stages and then are packaged and preserved by freezing. Despite aseptic care of the material those may be subjected to sterilization in the final packing by ionizing radiation, raising the security level of sterility of the tissue. The aim of this study was to evaluate the effects of application of ionizing radiation, produced by 60 Co source in human tendons pre-processed (A-alcohol + antibiotic; B- H 2 O 2 + ultrasound) obtained through collaboration with tissue banks and preserved by freezing in -80° C, the radiation absorbed doses in processing were 12.5, 15 and 25 kGy, each one with their corresponding non-irradiated control, to examine possible structural or morphological alterations. The irradiated samples and their controls were analyzed by means of optical coherence tomography (OCT) and optical coherence tomography polarization sensitive (PS-OCT), and histological tests had been stained with hematoxylin-eosin (HE). According to the results the tissue processed with alcohol/antibiotic in conjunction with irradiation proved to be the most effective. (author)

  2. Optical and histological evaluation in human tendon tissue sterilized by ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Funari, Ana Paula; Antebi, Uri; Santos, Luiz Augusto; Vieira, Daniel Perez; Miranda, Jurandir Tomaz de; Alves, Nelson Mendes; Freitas, Anderson Zanardi de; Mathor, Monica Beatriz, E-mail: anapaulafunari@gmail.com, E-mail: mathor@ipen.br, E-mail: uri@usp.br, E-mail: luiz.santos@hc.fm.usp.br, E-mail: tomazdemiranda.j@gmail.com, E-mail: nelsonnininho@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Faculdade de Ciências Médicas da Santa Casa de São Paulo, SP (Brazil); Universidade de São Paulo (USP), SP (Brazil). Faculdade de Medicina; Universidade Federal de Santa Maria (UFSM), RS (Brazil)

    2017-11-01

    Sterilization by irradiation is a technique that is used by tissue banks aiming to eliminate contamination of human allografts, being a safe method, free of residue and used as final sterilization. After the tissue procurement, these undergo a series of processing stages and then are packaged and preserved by freezing. Despite aseptic care of the material those may be subjected to sterilization in the final packing by ionizing radiation, raising the security level of sterility of the tissue. The aim of this study was to evaluate the effects of application of ionizing radiation, produced by {sup 60}Co source in human tendons pre-processed (A-alcohol + antibiotic; B- H{sub 2}O{sub 2} + ultrasound) obtained through collaboration with tissue banks and preserved by freezing in -80° C, the radiation absorbed doses in processing were 12.5, 15 and 25 kGy, each one with their corresponding non-irradiated control, to examine possible structural or morphological alterations. The irradiated samples and their controls were analyzed by means of optical coherence tomography (OCT) and optical coherence tomography polarization sensitive (PS-OCT), and histological tests had been stained with hematoxylin-eosin (HE). According to the results the tissue processed with alcohol/antibiotic in conjunction with irradiation proved to be the most effective. (author)

  3. Acousto-optic-assisted diffuse optical tomography

    NARCIS (Netherlands)

    Bratchenia, A.; Molenaar, Robert; van Leeuwen, Ton; Kooyman, R.P.H.

    2011-01-01

    We introduce and experimentally demonstrate acousto-optic-assisted diffuse optical tomography (DOT) using a holography-based acousto-optic setup. The method is based on probing a scattering medium with a localized acoustical modulation of the phase of the scattered light. The optical properties of

  4. CHIRALITY IN NONLINEAR OPTICS AND OPTICAL SWITCHING

    NARCIS (Netherlands)

    Meijer, E.W.; Feringa, B.L.

    1993-01-01

    Chirality in molecular opto-electronics is limited sofar to the use of optically active liquid crystals and a number of optical phenomena are related to the helical macroscopic structure obtained by using one enantiomer, only. In this paper, the use of chirality in nonlinear optics and optical

  5. Quantum Optics

    CERN Document Server

    Garrison, J C

    2008-01-01

    Quantum optics, i.e. the interaction of individual photons with matter, began with the discoveries of Planck and Einstein, but in recent years it has expanded beyond pure physics to become an important driving force for technological innovation. This book serves the broader readership growing out of this development by starting with an elementary description of the underlying physics and then building up a more advanced treatment. The reader is led from the quantum theory of thesimple harmonic oscillator to the application of entangled states to quantum information processing. An equally impor

  6. EDITORIAL: Optical orientation Optical orientation

    Science.gov (United States)

    SAME ADDRESS *, Yuri; Landwehr, Gottfried

    2008-11-01

    priority of the discovery in the literature, which was partly caused by the existence of the Iron Curtain. I had already enjoyed contact with Boris in the 1980s when the two volumes of Landau Level Spectroscopy were being prepared [2]. He was one of the pioneers of magneto-optics in semiconductors. In the 1950s the band structure of germanium and silicon was investigated by magneto-optical methods, mainly in the United States. No excitonic effects were observed and the band structure parameters were determined without taking account of excitons. However, working with cuprous oxide, which is a direct semiconductor with a relative large energy gap, Zakharchenya and his co-worker Seysan showed that in order to obtain correct band structure parameters, it is necessary to take excitons into account [3]. About 1970 Boris started work on optical orientation. Early work by Hanle in Germany in the 1920s on the depolarization of luminescence in mercury vapour by a transverse magnetic field was not appreciated for a long time. Only in the late 1940s did Kastler and co-workers in Paris begin a systematic study of optical pumping, which led to the award of a Nobel prize. The ideas of optical pumping were first applied by Georges Lampel to solid state physics in 1968. He demonstrated optical orientation of free carriers in silicon. The detection method was nuclear magnetic resonance; optically oriented free electrons dynamically polarized the 29Si nuclei of the host lattice. The first optical detection of spin orientation was demonstrated by with the III-V semiconductor GaSb by Parsons. Due to the various interaction mechanisms of spins with their environment, the effects occurring in semiconductors are naturally more complex than those in atoms. Optical detection is now the preferred method to detect spin alignment in semiconductors. The orientation of spins in crystals pumped with circularly polarized light is deduced from the degree of circular polarization of the recombination

  7. Optical Alignment of the Chromospheric Lyman-Alpha SpectroPolarimeter using Sophisticated Methods to Minimize Activities under Vacuum

    Science.gov (United States)

    Giono, G.; Katsukawa, Y.; Ishikawa, R.; Narukage, N.; Kano, R.; Kubo, M.; Ishikawa, S.; Bando, T.; Hara, H.; Suematsu, Y.; hide

    2016-01-01

    The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The in- strument main scientific goal is to achieve polarization measurement of the Lyman-alpha line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. For this purpose, the optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly- pro les. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-alpha is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We will explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We will then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.

  8. Advances in nonlinear optics

    CERN Document Server

    Chen, Xianfeng; Zeng, Heping; Guo, Qi; She, Weilong

    2015-01-01

    This book presents an overview of the state of the art of nonlinear optics from weak light nonlinear optics, ultrafast nonlinear optics to electro-optical theory and applications. Topics range from the fundamental studies of the interaction between matter and radiation to the development of devices, components, and systems of tremendous commercial interest for widespread applications in optical telecommunications, medicine, and biotechnology.

  9. Optical Assessment of Caries Lesion Structure and Activity

    Science.gov (United States)

    Lee, Robert Chulsung

    New, more sophisticated diagnostic tools are needed for the detection and characterization of caries lesions in the early stages of development. It is not sufficient to simply detect caries lesions, methods are needed to assess the activity of the lesion and determine if chemical or surgical intervention is needed. Previous studies have demonstrated that polarization sensitive optical coherence tomography (PS-OCT) can be used to nondestructively image the subsurface lesion structure and measure the thickness of the highly mineralized surface zone. Other studies have demonstrated that the rate of dehydration can be correlated with the lesion activity and that the rate can be measured using optical methods. The main objective of this work was to test the hypothesis that optical methods can be used to assess lesion activity on tooth coronal and root surfaces. Simulated caries models were used to develop and validate an algorithm for detecting and measuring the highly mineralized surface layer using PS-OCT. This work confirmed that the algorithm was capable of estimating the thickness of the highly mineralized surface layer with high accuracy. Near-infrared (NIR) reflectance and thermal imaging methods were used to assess activity of caries lesions by measuring the state of lesion hydration. NIR reflectance imaging performed the best for artificial enamel and natural coronal caries lesion samples, particularly at wavelengths coincident with the water absorption band at 1460-nm. However, thermal imaging performed the best for artificial dentin and natural root caries lesion samples. These novel optical methods outperformed the conventional methods (ICDAS II) in accurately assessing lesion activity of natural coronal and root caries lesions. Infrared-based imaging methods have shown potential for in-vivo applications to objectively assess caries lesion activity in a single examination. It is likely that if future clinical trials are a success, this novel imaging

  10. Quantum optics for experimentalists

    CERN Document Server

    Ou, Zhe-Yu Jeff

    2017-01-01

    This book on quantum optics is from the point of view of an experimentalist. It approaches the theory of quantum optics with the language of optical modes of classical wave theory, with which experimentalists are most familiar.

  11. Introduction to biomedical optics

    CERN Document Server

    Splinter, Robert

    2006-01-01

    GENERAL BIOMEDICAL OPTICS THEORYIntroduction to the Use of Light for Diagnostic and Therapeutic ModalitiesWhat Is Biomedical Optics?Biomedical Optics TimelineElementary Optical DiscoveriesHistorical Events in Therapeutic and Diagnostic Use of LightLight SourcesCurrent State of the ArtSummaryAdditional ReadingProblemsReview of Optical Principles: Fundamental Electromagnetic Theory and Description of Light SourcesDefinitions in OpticsKirchhoff's Laws of RadiationElectromagnetic Wave TheoryLight SourcesApplications of Various LasersSummaryAdditional ReadingProblemsReview of Optical Principles: Classical OpticsGeometrical OpticsOther Optical PrinciplesQuantum PhysicsGaussian OpticsSummaryAdditional ReadingProblemsReview of Optical Interaction PropertiesAbsorption and ScatteringSummaryAdditional ReadingProblemsLight-Tissue Interaction VariablesLaser VariablesTissue VariablesLight Transportation TheoryLight Propagation under Dominant AbsorptionSummaryNomenclatureAdditional ReadingProblemsLight-Tissue Interaction Th...

  12. Coding for optical channels

    CERN Document Server

    Djordjevic, Ivan; Vasic, Bane

    2010-01-01

    This unique book provides a coherent and comprehensive introduction to the fundamentals of optical communications, signal processing and coding for optical channels. It is the first to integrate the fundamentals of coding theory and optical communication.

  13. Tunable laser optics

    CERN Document Server

    Duarte, FJ

    2015-01-01

    This Second Edition of a bestselling book describes the optics and optical principles needed to build lasers. It also highlights the optics instrumentation necessary to characterize laser emissions and focuses on laser-based optical instrumentation. The book emphasizes practical and utilitarian aspects of relevant optics including the essential theory. This revised, expanded, and improved edition contains new material on tunable lasers and discusses relevant topics in quantum optics.

  14. Optical Remote Sensing Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optical Remote Sensing Laboratory deploys rugged, cutting-edge electro-optical instrumentation for the collection of various event signatures, with expertise in...

  15. Intelligent Optics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Intelligent Optics Laboratory supports sophisticated investigations on adaptive and nonlinear optics; advancedimaging and image processing; ground-to-ground and...

  16. Fibre-optic communications

    CERN Document Server

    Lecoy, Pierre

    2010-01-01

    This book describes in a comprehensive manner the components and systems of fiber optic communications and networks. The first section explains the theory of multimode and single-mode fibers, then the technological features, including manufacturing, cabling, and connecting. The second section describes the various components (passive and active optical components, integrated optics, opto-electronic transmitters and receivers, and optical amplifiers) used in fiber optic systems. Finally, the optical transmission system design is explained, and applications to optical networks and fiber optic se

  17. Fabrication and Design of Optical Nanomaterials

    Science.gov (United States)

    Huntington, Mark D.

    chapters 5 and 6, we focus on the design of optical nanomaterials. These chapters introduce a new type of artificially structured material--lattice opto-materials--that can achieve arbitrary light profiles with deep subwavelength accuracy in three dimensions. The driving innovation is the nexus of a computational approach to obtain a nano-optics genome and a paradigm shift in how to achieve structured optics that can operate at visible wavelengths based on different configurations of discrete units. We believe that lattice opto-materials represent a new class of engineered materials that have the potential to revolutionize micro and nano-optics. The development of new optics has a long history of driving key scientific discoveries, and we expect that lattice opto-materials could have a similarly transformative impact. For example, substrates with multiple focal points and in different planes could resolve different spatial locations in a cell simultaneously. Polarization-sensitive lattice opto-materials could also be used to prepare dynamic nano-optical traps for nanoparticles or even single atoms. We expect that lattice opto-materials designed by algorithmic approaches will open a wide range of new and unexpected applications.

  18. Light Optics for Optical Stochastic Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Andorf, Matthew [NICADD, DeKalb; Lebedev, Valeri [Fermilab; Piot, Philippe [NICADD, DeKalb; Ruan, Jinhao [Fermilab

    2016-06-01

    In Optical Stochastic Cooling (OSC) radiation generated by a particle in a "pickup" undulator is amplified and transported to a downstream "kicker" undulator where it interacts with the same particle which radiated it. Fermilab plans to carry out both passive (no optical amplifier) and active (optical amplifier) tests of OSC at the Integrable Optics Test Accelerator (IOTA) currently in construction*. The performace of the optical system is analyzed with simulations in Synchrotron Radiation Workshop (SRW) accounting for the specific temporal and spectral properties of undulator radiation and being augmented to include dispersion of lens material.

  19. Anisotropic optical properties of ZnS thin films with zigzag structure

    Indian Academy of Sciences (India)

    2017-08-18

    . In the earliest efforts on oblique angle deposition (OAD). [12] and GLAD [13], researchers observed polarization- sensitive properties and anisotropy originating from the microstructure in deposited films. When the incident ...

  20. Optic Nerve Pit

    Science.gov (United States)

    ... Conditions Frequently Asked Questions Español Condiciones Chinese Conditions Optic Nerve Pit What is optic nerve pit? An optic nerve pit is a ... may be seen in both eyes. How is optic pit diagnosed? If the pit is not affecting ...

  1. Optical image encryption topology.

    Science.gov (United States)

    Yong-Liang, Xiao; Xin, Zhou; Qiong-Hua, Wang; Sheng, Yuan; Yao-Yao, Chen

    2009-10-15

    Optical image encryption topology is proposed based on the principle of random-phase encoding. Various encryption topological units, involving peer-to-peer, ring, star, and tree topologies, can be realized by an optical 6f system. These topological units can be interconnected to constitute an optical image encryption network. The encryption and decryption can be performed in both digital and optical methods.

  2. Optics for dummies

    CERN Document Server

    Duree, Galen C

    2011-01-01

    The easy way to shed light on Optics In general terms, optics is the science of light. More specifically, optics is a branch of physics that describes the behavior and properties of light?including visible, infrared, and ultraviolet?and the interaction of light with matter. Optics For Dummies gives you an approachable introduction to optical science, methods, and applications. You'll get plain-English explanations of the nature of light and optical effects; reflection, refraction, and diffraction; color dispersion; optical devices, industrial, medical, and military applicatio

  3. Adaptive optics in microscopy.

    Science.gov (United States)

    Booth, Martin J

    2007-12-15

    The imaging properties of optical microscopes are often compromised by aberrations that reduce image resolution and contrast. Adaptive optics technology has been employed in various systems to correct these aberrations and restore performance. This has required various departures from the traditional adaptive optics schemes that are used in astronomy. This review discusses the sources of aberrations, their effects and their correction with adaptive optics, particularly in confocal and two-photon microscopes. Different methods of wavefront sensing, indirect aberration measurement and aberration correction devices are discussed. Applications of adaptive optics in the related areas of optical data storage, optical tweezers and micro/nanofabrication are also reviewed.

  4. Fiber optic connector

    Science.gov (United States)

    Rajic, Slobodan; Muhs, Jeffrey D.

    1996-01-01

    A fiber optic connector and method for connecting composite materials within which optical fibers are imbedded. The fiber optic connector includes a capillary tube for receiving optical fibers at opposing ends. The method involves inserting a first optical fiber into the capillary tube and imbedding the unit in the end of a softened composite material. The capillary tube is injected with a coupling medium which subsequently solidifies. The composite material is machined to a desired configuration. An external optical fiber is then inserted into the capillary tube after fluidizing the coupling medium, whereby the optical fibers are coupled.

  5. High contrast optical imaging methods for image guided laser ablation of dental caries lesions

    Science.gov (United States)

    LaMantia, Nicole R.; Tom, Henry; Chan, Kenneth H.; Simon, Jacob C.; Darling, Cynthia L.; Fried, Daniel

    2014-02-01

    Laser based methods are well suited for automation and can be used to selectively remove dental caries to minimize the loss of healthy tissues and render the underlying enamel more resistant to acid dissolution. The purpose of this study was to determine which imaging methods are best suited for image-guided ablation of natural non-cavitated carious lesions on occlusal surfaces. Multiple caries imaging methods were compared including near-IR and visible reflectance and quantitative light fluorescence (QLF). In order for image-guided laser ablation to be feasible, chemical and physical modification of tooth surfaces due to laser irradiation cannot greatly reduce the contrast between sound and demineralized dental hard tissues. Sound and demineralized surfaces of 48 extracted human molar teeth with non-cavitated lesions were examined. Images were acquired before and after laser irradiation using visible and near-IR reflectance and QLF at several wavelengths. Polarization sensitive-optical coherence tomography was used to confirm that lesions were present. The highest contrast was attained at 1460-nm and 1500-1700-nm, wavelengths coincident with higher water absorption. The reflectance did not decrease significantly after laser irradiation for those wavelengths.

  6. Integrated optics technology study

    Science.gov (United States)

    Chen, B.

    1982-01-01

    The materials and processes available for the fabrication of single mode integrated electrooptical components are described. Issues included in the study are: (1) host material and orientation, (2) waveguide formation, (3) optical loss mechanisms, (4) wavelength selection, (5) polarization effects and control, (6) laser to integrated optics coupling,(7) fiber optic waveguides to integrated optics coupling, (8) souces, (9) detectors. The best materials, technology and processes for fabrication of integrated optical components for communications and fiber gyro applications are recommended.

  7. Measurement of optical glasses

    International Nuclear Information System (INIS)

    Nicolau-Rebigan, S.

    1978-11-01

    The possibilities of measurement of the optical glasses parameters needed in building optical devices especially in lasers devices are presented. In the first chapter the general features of the main optical glasses as well as the modalities of obtaining them are given. Chapter two defines the optical glass parameters, and the third chapter describes the measuring methods of the optical glass parameters. Finally, the conclusions which point out the utilization of this paper are presented. (author)

  8. Optical imaging and spectroscopy

    CERN Document Server

    Brady, David J

    2009-01-01

    An essential reference for optical sensor system design This is the first text to present an integrated view of the optical and mathematical analysis tools necessary to understand computational optical system design. It presents the foundations of computational optical sensor design with a focus entirely on digital imaging and spectroscopy. It systematically covers: Coded aperture and tomographic imaging Sampling and transformations in optical systems, including wavelets and generalized sampling techniques essential to digital system analysis Geometric, wave, and statis

  9. Design of optical switches by illusion optics

    International Nuclear Information System (INIS)

    Shoorian, H R; Abrishamian, M S

    2013-01-01

    In this paper, illusion optics theory is employed to form Bragg gratings in an optical waveguide in order to design an optical switch. By using an illusion device at a certain distance from the waveguide, the effective refractive index of the waveguide is remotely modulated, turning the waveguide into a distributed Bragg reflector (DBR) which blocks the waves at a stop band. By removing the illusion device, the waves propagate through the waveguide again. In addition, this method is used to remotely tune DBR optical properties such as resonant frequency and bandwidth in a wide range, which leads to a tunable filter for optical switching applications. Finally, using an illusion device at a distance, an optical cavity is created by inserting defects remotely in a DBR without any physical damage in the primary device. (paper)

  10. Design of optical switches by illusion optics

    Science.gov (United States)

    Shoorian, H. R.; Abrishamian, M. S.

    2013-05-01

    In this paper, illusion optics theory is employed to form Bragg gratings in an optical waveguide in order to design an optical switch. By using an illusion device at a certain distance from the waveguide, the effective refractive index of the waveguide is remotely modulated, turning the waveguide into a distributed Bragg reflector (DBR) which blocks the waves at a stop band. By removing the illusion device, the waves propagate through the waveguide again. In addition, this method is used to remotely tune DBR optical properties such as resonant frequency and bandwidth in a wide range, which leads to a tunable filter for optical switching applications. Finally, using an illusion device at a distance, an optical cavity is created by inserting defects remotely in a DBR without any physical damage in the primary device.

  11. Nonlinear Optics and Applications

    Science.gov (United States)

    Abdeldayem, Hossin A. (Editor); Frazier, Donald O. (Editor)

    2007-01-01

    Nonlinear optics is the result of laser beam interaction with materials and started with the advent of lasers in the early 1960s. The field is growing daily and plays a major role in emerging photonic technology. Nonlinear optics play a major role in many of the optical applications such as optical signal processing, optical computers, ultrafast switches, ultra-short pulsed lasers, sensors, laser amplifiers, and many others. This special review volume on Nonlinear Optics and Applications is intended for those who want to be aware of the most recent technology. This book presents a survey of the recent advances of nonlinear optical applications. Emphasis will be on novel devices and materials, switching technology, optical computing, and important experimental results. Recent developments in topics which are of historical interest to researchers, and in the same time of potential use in the fields of all-optical communication and computing technologies, are also included. Additionally, a few new related topics which might provoke discussion are presented. The book includes chapters on nonlinear optics and applications; the nonlinear Schrodinger and associated equations that model spatio-temporal propagation; the supercontinuum light source; wideband ultrashort pulse fiber laser sources; lattice fabrication as well as their linear and nonlinear light guiding properties; the second-order EO effect (Pockels), the third-order (Kerr) and thermo-optical effects in optical waveguides and their applications in optical communication; and, the effect of magnetic field and its role in nonlinear optics, among other chapters.

  12. Introduction to nonimaging optics

    CERN Document Server

    Chaves, Julio

    2015-01-01

    Introduction to Nonimaging Optics covers the theoretical foundations and design methods of nonimaging optics, as well as key concepts from related fields. This fully updated, revised, and expanded Second Edition: Features a new and intuitive introduction with a basic description of the advantages of nonimaging opticsAdds new chapters on wavefronts for a prescribed output (irradiance or intensity), infinitesimal étendue optics (generalization of the aplanatic optics), and Köhler optics and color mixingIncorporates new material on the simultaneous multiple surface (SMS) design method in 3-D, int

  13. From optics testing to micro optics testing

    Science.gov (United States)

    Brock, Christian; Dorn, Ralf; Pfund, Johannes

    2017-10-01

    Testing micro optics, i.e. lenses with dimensions down to 0.1mm and less, with high precision requires a dedicated design of the testing device, taking into account propagation and wave-optical effects. In this paper, we discuss testing methods based on Shack-Hartmann wavefront technology for functional testing in transmission and for the measurement of surface shape in reflection. As a first example of more conventional optics testing, i.e. optics in the millimeter range, we present the measurement of binoculars in transmission, and discuss the measured wave aberrations and imaging quality. By repeating the measurement at different wavelengths, information on chromatic effects is retrieved. A task that is often tackled using Shack-Hartman wavefront sensors is the alignment of collimation optics in front of a light source. In case of a micro-optical collimation unit with a 1/e² beam diameter of ca. 1mm, we need adapted relay optics for suitable beam expansion and well-defined imaging conditions. In this example, we will discuss the alignment process and effects of the relay optics magnification, as well as typical performance data. Oftentimes, micro optics are fabricated not as single pieces, but as mass optics, e.g. by lithographic processes. Thus, in order to reduce tooling and alignment time, an automated test procedure is necessary. We present an approach for the automated testing of wafer- or tray-based micro optics, and discuss transmission and reflection measurement capabilities. Exemplary performance data is shown for a sample type with 30 microns in diameter, where typical repeatabilities of a few nanometers (rms) are reached.

  14. bicep2/ KECK ARRAY . IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P.A.R.; Aikin, R.W.; Barkats, D.; Benton, S.J.; Bischoff, C.A.; Bock, J.J.; Bradford, K.J.; Brevik, J.A.; Buder, I.; Bullock, E.; Dowell, C.D.; Duband, L.; Filippini, J.P.; Fliescher, S.; Golwala, S.R.; Halpern, M.; Hasselfield, M.; Hildebrandt, S.R.; Hilton, G.C.; Hui, H.; Irwin, K.D.

    2015-06-18

    bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS P. A. R. Ade1, R. W. Aikin2, D. Barkats3, S. J. Benton4, C. A. Bischoff5, J. J. Bock2,6, K. J. Bradford5, J. A. Brevik2, I. Buder5, E. Bullock7Show full author list Published 2015 June 18 • © 2015. The American Astronomical Society. All rights reserved. The Astrophysical Journal, Volume 806, Number 2 Article PDF Figures Tables References Citations 273 Total downloads Cited by 6 articles Turn on MathJax Share this article Get permission to re-use this article Article information Abstract bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

  15. Miniature Optical Isolator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — To address NASA's need for miniature optical isolators in atom interferometry applications, Physical Optics Corporation (POC) proposes to develop a miniature optical...

  16. Peptide Optical waveguides.

    Science.gov (United States)

    Handelman, Amir; Apter, Boris; Shostak, Tamar; Rosenman, Gil

    2017-02-01

    Small-scale optical devices, designed and fabricated onto one dielectric substrate, create integrated optical chip like their microelectronic analogues. These photonic circuits, based on diverse physical phenomena such as light-matter interaction, propagation of electromagnetic waves in a thin dielectric material, nonlinear and electro-optical effects, allow transmission, distribution, modulation, and processing of optical signals in optical communication systems, chemical and biological sensors, and more. The key component of these optical circuits providing both optical processing and photonic interconnections is light waveguides. Optical confinement and transmitting of the optical waves inside the waveguide material are possible due to the higher refractive index of the waveguides in comparison with their surroundings. In this work, we propose a novel field of bionanophotonics based on a new concept of optical waveguiding in synthetic elongated peptide nanostructures composed of ordered peptide dipole biomolecules. New technology of controllable deposition of peptide optical waveguiding structures by nanofountain pen technique is developed. Experimental studies of refractive index, optical transparency, and linear and nonlinear waveguiding in out-of-plane and in-plane diphenylalanine peptide nanotubes have been conducted. Optical waveguiding phenomena in peptide structures are simulated by the finite difference time domain method. The advantages of this new class of bio-optical waveguides are high refractive index contrast, wide spectral range of optical transparency, large optical nonlinearity, and electro-optical effect, making them promising for new applications in integrated multifunctional photonic circuits. Copyright © 2016 European Peptide Society and John Wiley & Sons, Ltd. Copyright © 2016 European Peptide Society and John Wiley & Sons, Ltd.

  17. Optical Airborne Tracker System

    Data.gov (United States)

    National Aeronautics and Space Administration — The Optical Airborne Tracker System (OATS) is an airborne dual-axis optical tracking system capable of pointing at any sky location or ground target.  The objectives...

  18. The Scanning Optical Microscope.

    Science.gov (United States)

    Sheppard, C. J. R.

    1978-01-01

    Describes the principle of the scanning optical microscope and explains its advantages over the conventional microscope in the improvement of resolution and contrast, as well as the possibility of producing a picture from optical harmonies generated within the specimen.

  19. Optics for SIERRA

    Data.gov (United States)

    National Aeronautics and Space Administration — To demonstrate a massively parallel optical ray trace to enable the design and analysis of extremely large aperture optical systems. This, in turn, enables...

  20. Fiber Optics Technology.

    Science.gov (United States)

    Burns, William E.

    1986-01-01

    Discusses various applications of fiber optics technology: information systems, industrial robots, medicine, television, transportation, and training. Types of jobs that will be available with fiber optics training (such as electricians and telephone cable installers and splicers) are examined. (CT)

  1. Fiber Optics Instrumentation Development

    Science.gov (United States)

    Chan, Patrick Hon Man; Parker, Allen R., Jr.; Richards, W. Lance

    2010-01-01

    This is a general presentation of fiber optics instrumentation development work being conducted at NASA Dryden for the past 10 years and recent achievements in the field of fiber optics strain sensors.

  2. Optical illusion: apogee development

    OpenAIRE

    Elena, Chernyсhuk; Bazylevych, Viktoriya

    2015-01-01

    The article provides a classification of optical illusions performed by the authors. Briefly described each of the 11 identified species. Offered the variants using optical illusions in the urban environment, exterior and interior.

  3. Advanced digital optical communications

    CERN Document Server

    Binh, Le Nguyen

    2015-01-01

    This book provides a fundamental understanding of digital communication applications in optical communication technologies. Emphasizing operation principles versus mathematical analysis, the Second Edition includes new coverage of superchannel optical transmission systems, metropolitan and long-haul optical systems and networks, and Nyquist pulse shaping and high spectral efficiency of optical transmission systems, as well as new homework problems and examples. Featuring theoretical foundations as well as practical case studies, the text focuses on enhancements to digital technologies that are

  4. Emerging Correlation Optics

    DEFF Research Database (Denmark)

    Angelsky, Oleg V.; Gbur, Gregory J.; Polyanskii, Peter

    2012-01-01

    This feature issue of Applied Optics contains a series of selected papers reflecting the state-of-the-art of correlation optics and showing synergetics between the theoretical background and experimental techniques.......This feature issue of Applied Optics contains a series of selected papers reflecting the state-of-the-art of correlation optics and showing synergetics between the theoretical background and experimental techniques....

  5. Progress in optics

    CERN Document Server

    Wolf, Emil

    2009-01-01

    In the fourty-seven years that have gone by since the first volume of Progress in Optics was published, optics has become one of the most dynamic fields of science. The volumes in this series which have appeared up to now contain more than 300 review articles by distinguished research workers, which have become permanent records for many important developments.- Backscattering and Anderson localization of light- Advances in oliton manipulation in optical lattices- Fundamental quantum noise in optical amplification- Invisibility cloaks

  6. Progress in optics

    CERN Document Server

    Wolf, Emil

    2015-01-01

    The Progress in Optics series contains more than 300 review articles by distinguished research workers, which have become permanent records for many important developments, helping optical scientists and optical engineers stay abreast of their fields. Comprehensive, in-depth reviewsEdited by the leading authority in the field

  7. Multiplane optical microscope

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tongcang; Ota, Sadao; Kim, Jeongmin; Wang, Yuan; Zhang, Xiang

    2017-11-21

    This disclosure provides systems, methods, and apparatus related to optical microscopy. In one aspect, an apparatus includes a sample holder, a first objective lens, a plurality of optical components, a second objective lens, and a mirror. The apparatus may directly image a cross-section of a sample oblique to or parallel to the optical axis of the first objective lens, without scanning.

  8. Fun with Optical Fibres

    Science.gov (United States)

    Alti, Kamlesh

    2017-01-01

    Optical fibres play a very crucial role in today's technologies. Academic courses in optical fibres start at the undergraduate level. Nevertheless, student's curiosity towards optical fibres starts from the school level. In this paper, some fun experiments have been designed for both school and college students, which have some concrete…

  9. Optical ordinal optimization

    Science.gov (United States)

    Caulfield, H. John

    2000-07-01

    Ordinal optimization is a relatively new field of mathematics that seems never to have been applied to optics. Optics has made extensive use of traditional cardinal optimization. This paper explores the possibility that ordinal optimization might be useful in optics. The conclusion is: Not directly but indirectly.

  10. Validity of automated choroidal segmentation in SS-OCT and SD-OCT

    NARCIS (Netherlands)

    L. Zhang (Li); G.H.S. Buitendijk (Gabrielle); K. Lee (Kyungmoo); M. Sonka (Milan); H. Springelkamp (Henriët); A. Hofman (Albert); J.R. Vingerling (Hans); R.F. Mullins (Robert F.); C.C.W. Klaver (Caroline); M.D. Abràmoff (Michael)

    2015-01-01

    textabstractPURPOSE. To evaluate the validity of a novel fully automated three-dimensional (3D) method capable of segmenting the choroid from two different optical coherence tomography scanners: swept-source OCT (SS-OCT) and spectral-domain OCT (SD-OCT). METHODS. One hundred eight subjects were

  11. Development of Multi-chroic Millimeter-wave Polarization Sensitive Detector Arrays

    Data.gov (United States)

    National Aeronautics and Space Administration — Improved measurements of the polarization of the Cosmic Microwave Background (CMB) will improve our understanding of both cosmology and fundamental physics....

  12. The Polarization-Sensitive Bolometers for SPICA and their Potential Use for Ground-Based Application

    Science.gov (United States)

    Reveret, Vincent

    2018-01-01

    CEA is leading the development of Safari-POL, an imaging-polarimeter aboard the SPICA space observatory (ESA M5). SPICA will be able to reach unprecedented sensitivities thanks to its cooled telescope and its ultra-sensitive detectors. The detector assembly of Safari-POL holds three arrays that are cooled down to 50 mK and correspond to three spectral bands : 100, 200 and 350 microns. The detectors (silicon bolometers), benefit from the Herschel/PACS legacy and are also a big step forward in term of sensitivity (improved by two orders of magnitude compared to PACS bolometers) and for polarimetry capabilities. Indeed, each pixel is intrinsically sensitive to two polarization components (Horizontal and Vertical). We will present the Safari-POL concept, the first results of measurements made on the detectors, and future plans for possible ground-based instruments using this technology. We will also present the example of the ArTéMiS camera, installed at APEX, that was developped as a ground-based conterpart of the PACS photometer.

  13. Excitation polarization sensitivity of plasmon-mediated silver nanotriangle growth on a surface.

    Science.gov (United States)

    Paul, Aniruddha; Kenens, Bart; Hofkens, Johan; Uji-i, Hiroshi

    2012-06-19

    In this contribution, we report an effective and relatively simple route to grow triangular flat-top silver nanoparticles (NPs) directly on a solid substrate from smaller NPs through a wet photochemical synthesis. The method consists of fixing small, preformed nanotriangles (NTs) on a substrate and subsequently irradiating them with light in a silver seed solution. Furthermore, the use of linearly polarized light allows for exerting control on the growth direction of the silver nanotriangles on the substrate. Evidence for the role of surface plasmon resonances in governing the growth of the NTs is obtained by employing linear polarized light. Thus, this study demonstrates that light-induced, directional synthesis of nanoparticles on solid substrates is in reach, which is of utmost importance for plasmonic applications.

  14. Retinal processing and opponent mechanisms mediating ultraviolet polarization sensitivity in rainbow trout (Oncorhynchus mykiss)

    NARCIS (Netherlands)

    Ramsden, Samuel D.; Anderson, Leslie; Mussi, Martina; Kamermans, Maarten; Hawryshyn, Craig W.

    2008-01-01

    A number of teleost fishes have photoreceptor mechanisms to detect linearly polarized light. We studied the neuronal mechanism underlying this ability. It was found that a polarized signal could be detected in rainbow trout (Oncorhynchus mykiss) both in the electroretinogram (ERG) and in the

  15. Near perfect optics

    Energy Technology Data Exchange (ETDEWEB)

    Goeke, R.; Farnsworth, A.V.; Neumann, C.C.; Sweatt, W.C.; Warren, M.E.; Weed, J.W.

    1996-06-01

    This report discusses a novel fabrication process to produce nearly perfect optics. The process utilizes vacuum deposition techniques to optimally modify polished optical substrate surfaces. The surface figure, i.e. contour of a polished optical element, is improved by differentially filling in the low spots on the surface using flux from a physical vapor deposition source through an appropriate mask. The process is expected to enable the manufacture of diffraction-limited optical systems for the UV, extreme UV, and soft X-ray spectral regions, which would have great impact on photolithography and astronomy. This same technique may also reduce the fabrication cost of visible region optics with aspheric surfaces.

  16. Optical modulator including grapene

    Science.gov (United States)

    Liu, Ming; Yin, Xiaobo; Zhang, Xiang

    2016-06-07

    The present invention provides for a one or more layer graphene optical modulator. In a first exemplary embodiment the optical modulator includes an optical waveguide, a nanoscale oxide spacer adjacent to a working region of the waveguide, and a monolayer graphene sheet adjacent to the spacer. In a second exemplary embodiment, the optical modulator includes at least one pair of active media, where the pair includes an oxide spacer, a first monolayer graphene sheet adjacent to a first side of the spacer, and a second monolayer graphene sheet adjacent to a second side of the spacer, and at least one optical waveguide adjacent to the pair.

  17. Optical Binding of Nanowires

    Czech Academy of Sciences Publication Activity Database

    Simpson, Stephen Hugh; Zemánek, Pavel; Marago, O.M.; Jones, P.H.; Hanna, S.

    2017-01-01

    Roč. 17, č. 6 (2017), s. 3485-3492 ISSN 1530-6984 R&D Projects: GA ČR GB14-36681G Grant - others:AV ČR(CZ) CNR-16-12 Program:Bilaterální spolupráce Institutional support: RVO:68081731 Keywords : optical binding nanowires * Brownian motion * self -organization * non-equilibrium thermodynamics * non-equilibrium steady state * spin-orbit coupling * emergent phenomena Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 12.712, year: 2016

  18. Small scale optics

    CERN Document Server

    Yupapin, Preecha

    2013-01-01

    The behavior of light in small scale optics or nano/micro optical devices has shown promising results, which can be used for basic and applied research, especially in nanoelectronics. Small Scale Optics presents the use of optical nonlinear behaviors for spins, antennae, and whispering gallery modes within micro/nano devices and circuits, which can be used in many applications. This book proposes a new design for a small scale optical device-a microring resonator device. Most chapters are based on the proposed device, which uses a configuration know as a PANDA ring resonator. Analytical and nu

  19. [Adaptive optics for ophthalmology].

    Science.gov (United States)

    Saleh, M

    2016-04-01

    Adaptive optics is a technology enhancing the visual performance of an optical system by correcting its optical aberrations. Adaptive optics have already enabled several breakthroughs in the field of visual sciences, such as improvement of visual acuity in normal and diseased eyes beyond physiologic limits, and the correction of presbyopia. Adaptive optics technology also provides high-resolution, in vivo imaging of the retina that may eventually help to detect the onset of retinal conditions at an early stage and provide better assessment of treatment efficacy. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Optic disc oedema

    DEFF Research Database (Denmark)

    Nielsen, Marianne Kromann; Hamann, Steffen

    2014-01-01

    Optic disc oedema describes the nonspecific, localized swelling of the optic nerve head regardless of aetiology. Therefore, differentiating among the various aetiologies depends on a thorough history and knowledge of the clinical characteristics of the underlying conditions. Papilloedema strictly...... refers to optic disc oedema as a consequence of elevated intracranial pressure. It is usually a bilateral condition and visual function is preserved until late. Optic disc oedema caused by an anterior optic neuropathy is usually unilateral and accompanied by the loss of visual function....

  1. Progress in optics

    CERN Document Server

    Wolf, Emil

    2006-01-01

    In the thirty-seven years that have gone by since the first volume of Progress in Optics was published, optics has become one of the most dynamic fields of science. At the time of inception of this series, the first lasers were only just becoming operational, holography was in its infancy, subjects such as fiber optics, integrated optics and optoelectronics did not exist and quantum optics was the domain of only a few physicists. The term photonics had not yet been coined. Today these fields are flourishing and have become areas of specialisation for many science and engineering students and n

  2. Progress in optics

    CERN Document Server

    Wolf, Emil

    1977-01-01

    In the thirty-seven years that have gone by since the first volume of Progress in Optics was published, optics has become one of the most dynamic fields of science. At the time of inception of this series, the first lasers were only just becoming operational, holography was in its infancy, subjects such as fiber optics, integrated optics and optoelectronics did not exist and quantum optics was the domain of only a few physicists. The term photonics had not yet been coined. Today these fields are flourishing and have become areas of specialisation for many science and engineering students and n

  3. Peptide Integrated Optics.

    Science.gov (United States)

    Handelman, Amir; Lapshina, Nadezda; Apter, Boris; Rosenman, Gil

    2018-02-01

    Bio-nanophotonics is a wide field in which advanced optical materials, biomedicine, fundamental optics, and nanotechnology are combined and result in the development of biomedical optical chips. Silk fibers or synthetic bioabsorbable polymers are the main light-guiding components. In this work, an advanced concept of integrated bio-optics is proposed, which is based on bioinspired peptide optical materials exhibiting wide optical transparency, nonlinear and electrooptical properties, and effective passive and active waveguiding. Developed new technology combining bottom-up controlled deposition of peptide planar wafers of a large area and top-down focus ion beam lithography provides direct fabrication of peptide optical integrated circuits. Finding a deep modification of peptide optical properties by reconformation of biological secondary structure from native phase to β-sheet architecture is followed by the appearance of visible fluorescence and unexpected transition from a native passive optical waveguiding to an active one. Original biocompatibility, switchable regimes of waveguiding, and multifunctional nonlinear optical properties make these new peptide planar optical materials attractive for application in emerging technology of lab-on-biochips, combining biomedical photonic and electronic circuits toward medical diagnosis, light-activated therapy, and health monitoring. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Nonlinear optical systems

    CERN Document Server

    Lugiato, Luigi; Brambilla, Massimo

    2015-01-01

    Guiding graduate students and researchers through the complex world of laser physics and nonlinear optics, this book provides an in-depth exploration of the dynamics of lasers and other relevant optical systems, under the umbrella of a unitary spatio-temporal vision. Adopting a balanced approach, the book covers traditional as well as special topics in laser physics, quantum electronics and nonlinear optics, treating them from the viewpoint of nonlinear dynamical systems. These include laser emission, frequency generation, solitons, optically bistable systems, pulsations and chaos and optical pattern formation. It also provides a coherent and up-to-date treatment of the hierarchy of nonlinear optical models and of the rich variety of phenomena they describe, helping readers to understand the limits of validity of each model and the connections among the phenomena. It is ideal for graduate students and researchers in nonlinear optics, quantum electronics, laser physics and photonics.

  5. Optical logic: an overview

    Science.gov (United States)

    Caulfield, H. John

    2005-05-01

    Progress of optical logic has been anything but uniform or even monotonic. The hope for "all optical computers" was largely abandoned after devastating critiques by Keyes. Over time, optical logic transformed into a very viable niche activity by the needs of optical communication for "all optical" logic and the advent of a critical component: the SOA or Semiconductor Optical Amplifier. I argue that a new phase in this uneven history can be defined - linear (single photon, not multiple entangled photon) quantum optical logic. These can perform conservative, reversible logic operations without energy or time penalties, but cascading requires the irreversible act of measurement, so only single devices or single layers can deliver those advantages.

  6. Optic nerve oxygenation

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Pedersen, Daniella Bach; Jensen, Peter Koch

    2005-01-01

    The oxygen tension of the optic nerve is regulated by the intraocular pressure and systemic blood pressure, the resistance in the blood vessels and oxygen consumption of the tissue. The oxygen tension is autoregulated and moderate changes in intraocular pressure or blood pressure do not affect...... the optic nerve oxygen tension. If the intraocular pressure is increased above 40 mmHg or the ocular perfusion pressure decreased below 50 mmHg the autoregulation is overwhelmed and the optic nerve becomes hypoxic. A disturbance in oxidative metabolism in the cytochromes of the optic nerve can be seen...... at similar levels of perfusion pressure. The levels of perfusion pressure that lead to optic nerve hypoxia in the laboratory correspond remarkably well to the levels that increase the risk of glaucomatous optic nerve atrophy in human glaucoma patients. The risk for progressive optic nerve atrophy in human...

  7. Optic nerve oxygenation

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Pedersen, Daniella Bach; Jensen, Peter Koch

    2005-01-01

    at similar levels of perfusion pressure. The levels of perfusion pressure that lead to optic nerve hypoxia in the laboratory correspond remarkably well to the levels that increase the risk of glaucomatous optic nerve atrophy in human glaucoma patients. The risk for progressive optic nerve atrophy in human...... glaucoma patients is six times higher at a perfusion pressure of 30 mmHg, which corresponds to a level where the optic nerve is hypoxic in experimental animals, as compared to perfusion pressure levels above 50 mmHg where the optic nerve is normoxic. Medical intervention can affect optic nerve oxygen......-oxygenase inhibitor, indomethacin, which indicates that prostaglandin metabolism plays a role. Laboratory studies suggest that carbonic anhydrase inhibitors might be useful for medical treatment of optic nerve and retinal ischemia, potentially in diseases such as glaucoma and diabetic retinopathy. However, clinical...

  8. Optical system design

    CERN Document Server

    Fischer, Robert F

    2008-01-01

    Honed for more than 20 years in an SPIE professional course taught by renowned optical systems designer Robert E. Fischer, Optical System Design, Second Edition brings you the latest cutting-edge design techniques and more than 400 detailed diagrams that clearly illustrate every major procedure in optical design. This thoroughly updated resource helps you work better and faster with computer-aided optical design techniques, diffractive optics, and the latest applications, including digital imaging, telecommunications, and machine vision. No need for complex, unnecessary mathematical derivations-instead, you get hundreds of examples that break the techniques down into understandable steps. For twenty-first century optical design without the mystery, the authoritative Optical Systems Design, Second Edition features: Computer-aided design use explained through sample problems Case studies of third-millennium applications in digital imaging, sensors, lasers, machine vision, and more New chapters on optomechanic...

  9. MEMS optical sensor

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to an all-optical sensor utilizing effective index modulation of a waveguide and detection of a wavelength shift of reflected light and a force sensing system accommodating said optical sensor. One embodiment of the invention relates to a sensor system comprising...... at least one multimode light source, one or more optical sensors comprising a multimode sensor optical waveguide accommodating a distributed Bragg reflector, at least one transmitting optical waveguide for guiding light from said at least one light source to said one or more multimode sensor optical...... waveguides, a detector for measuring light reflected from said Bragg reflector in said one or more multimode sensor optical waveguides, and a data processor adapted for analyzing variations in the Bragg wavelength of at least one higher order mode of the reflected light....

  10. Accuracies Of Optical Processors For Adaptive Optics

    Science.gov (United States)

    Downie, John D.; Goodman, Joseph W.

    1992-01-01

    Paper presents analysis of accuracies and requirements concerning accuracies of optical linear-algebra processors (OLAP's) in adaptive-optics imaging systems. Much faster than digital electronic processor and eliminate some residual distortion. Question whether errors introduced by analog processing of OLAP overcome advantage of greater speed. Paper addresses issue by presenting estimate of accuracy required in general OLAP that yields smaller average residual aberration of wave front than digital electronic processor computing at given speed.

  11. Fibre-optical microendoscopy.

    Science.gov (United States)

    Gu, M; Bao, H; Kang, H

    2014-04-01

    Microendoscopy has been an essential tool in exploring micro/nano mechanisms in vivo due to high-quality imaging performance, compact size and flexible movement. The investigations into optical fibres, micro-scanners and miniature lens have boosted efficiencies of remote light delivery to sample site and signal collection. Given the light interaction with materials in the fluorescence imaging regime, this paper reviews two classes of compact microendoscopy based on a single fibre: linear optical microendoscopy and nonlinear optical microendoscopy. Due to the fact that fluorescence occurs only in the focal volume, nonlinear optical microendoscopy can provide stronger optical sectioning ability than linear optical microendoscopy, and is a good candidate for deep tissue imaging. Moreover, one-photon excited fluorescence microendoscopy as the linear optical microendoscopy suffers from severe photobleaching owing to the linear dependence of photobleaching rate on excitation laser power. On the contrary, nonlinear optical microendoscopy, including two-photon excited fluorescence microendoscopy and second harmonic generation microendoscopy, has the capability to minimize or avoid the photobleaching effect at a high excitation power and generate high image contrast. The combination of various nonlinear signals gained by the nonlinear optical microendoscopy provides a comprehensive insight into biophenomena in internal organs. Fibre-optical microendoscopy overcomes physical limitations of traditional microscopy and opens up a new path to achieve early cancer diagnosis and microsurgery in a minimally invasive and localized manner. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  12. Advances in integrated optics

    CERN Document Server

    Chester, A; Bertolotti, M

    1994-01-01

    This volwne contains the Proceedings of a two-week summer conference titled "Advances in Integrated Optics" held June 1-9, 1993, in Erice, Sicily. This was the 18th annual course organized by the International School of Quantum Electronics, under the auspices of the "Ettore Majorana" Centre for Scientific Culture. The term Integrated Optics signifies guided-wave optical circuits consisting of two or more devices on a single substrate. Since its inception in the late 1960's, Integrated Optics has evolved from a specialized research topic into a broad field of work, ranging from basic research through commercial applications. Today many devices are available on market while a big effort is devolved to research on integrated nonlinear optical devices. This conference was organized to provide a comprehensive survey of the frontiers of this technology, including fundamental concepts, nonlinear optical materials, devices both in the linear and nonlinear regimes, and selected applications. These Proceedings update a...

  13. Silicon Optical Modulator Simulation

    Directory of Open Access Journals (Sweden)

    Soon Thor LIM

    2015-04-01

    Full Text Available We developed a way of predicting and analyzing high speed optical modulator. Our research adopted a bottom-up approach to consider high-speed optical links using an eye diagram. Our method leverages on modular mapping of electrical characteristics to optical characteristics, while attaining the required accuracy necessary for device footprint approaching sub-micron scales where electrical data distribution varies drastically. We calculate for the bias dependent phase shift (2pi/mm and loss (dB/mm for the optical modulator based on the real and imaginary part of complex effective indices. Subsequently, combine effectively both the electrical and optical profiles to construct the optical eye diagram which is the essential gist of signal integrity of such devices.

  14. Fundamentals of optical waveguides

    CERN Document Server

    Okamoto, Katsunari

    2006-01-01

    Fundamentals of Optical Waveguides is an essential resource for any researcher, professional or student involved in optics and communications engineering. Any reader interested in designing or actively working with optical devices must have a firm grasp of the principles of lightwave propagation. Katsunari Okamoto has presented this difficult technology clearly and concisely with several illustrations and equations. Optical theory encompassed in this reference includes coupled mode theory, nonlinear optical effects, finite element method, beam propagation method, staircase concatenation method, along with several central theorems and formulas. Since the publication of the well-received first edition of this book, planar lightwave circuits and photonic crystal fibers have fully matured. With this second edition the advances of these fibers along with other improvements on existing optical technologies are completely detailed. This comprehensive volume enables readers to fully analyze, design and simulate opti...

  15. Lasers and optical engineering

    CERN Document Server

    Das, P

    1991-01-01

    A textbook on lasers and optical engineering should include all aspects of lasers and optics; however, this is a large undertaking. The objective of this book is to give an introduction to the subject on a level such that under­ graduate students (mostly juniors/seniors), from disciplines like electrical engineering, physics, and optical engineering, can use the book. To achieve this goal, a lot of basic background material, central to the subject, has been covered in optics and laser physics. Students with an elementary knowledge of freshman physics and with no formal courses in electromagnetic theory should be able to follow the book, although for some sections, knowledge of electromagnetic theory, the Fourier transform, and linear systems would be highly beneficial. There are excellent books on optics, laser physics, and optical engineering. Actually, most of my knowledge was acquired through these. However, when I started teaching an undergraduate course in 1974, under the same heading as the title of th...

  16. Tunable micro-optics

    CERN Document Server

    Duppé, Claudia

    2015-01-01

    Presenting state-of-the-art research into the dynamic field of tunable micro-optics, this is the first book to provide a comprehensive survey covering a varied range of topics including novel materials, actuation concepts and new imaging systems in optics. Internationally renowned researchers present a diverse range of chapters on cutting-edge materials, devices and subsystems, including soft matter, artificial muscles, tunable lenses and apertures, photonic crystals, and complete tunable imagers. Special contributions also provide in-depth treatment of micro-optical characterisation, scanners, and the use of natural eye models as inspiration for new concepts in advanced optics. With applications extending from medical diagnosis to fibre telecommunications, Tunable Micro-optics equips readers with a solid understanding of the broader technical context through its interdisciplinary approach to the realisation of new types of optical systems. This is an essential resource for engineers in industry and academia,...

  17. Progress in optics

    CERN Document Server

    Wolf, Emil

    2008-01-01

    In the fourty-six years that have gone by since the first volume of Progress in Optics was published, optics has become one of the most dynamic fields of science. The volumes in this series which have appeared up to now contain more than 300 review articles by distinguished research workers, which have become permanent records for many important developments.- Metamaterials- Polarization Techniques- Linear Baisotropic Mediums- Ultrafast Optical Pulses- Quantum Imaging- Point-Spread Funcions- Discrete Wigner Functions

  18. Optical atomic magnetometer

    Science.gov (United States)

    Budker, Dmitry; Higbie, James; Corsini, Eric P

    2013-11-19

    An optical atomic magnetometers is provided operating on the principles of nonlinear magneto-optical rotation. An atomic vapor is optically pumped using linearly polarized modulated light. The vapor is then probed using a non-modulated linearly polarized light beam. The resulting modulation in polarization angle of the probe light is detected and used in a feedback loop to induce self-oscillation at the resonant frequency.

  19. Dominant optic atrophy

    DEFF Research Database (Denmark)

    Lenaers, Guy; Hamel, Christian; Delettre, Cécile

    2012-01-01

    DEFINITION OF THE DISEASE: Dominant Optic Atrophy (DOA) is a neuro-ophthalmic condition characterized by a bilateral degeneration of the optic nerves, causing insidious visual loss, typically starting during the first decade of life. The disease affects primary the retinal ganglion cells (RGC) an......) and their axons forming the optic nerve, which transfer the visual information from the photoreceptors to the lateral geniculus in the brain....

  20. Concepts of classical optics

    CERN Document Server

    Strong, John

    1958-01-01

    An intermediate course in optics, this volume explores both experimental and theoretical concepts, offering practical knowledge of geometrical optics that will enhance students' comprehension of any relevant applied science. Its exposition of the concepts of classical optics is presented with a minimum of mathematical detail but presumes some knowledge of calculus, vectors, and complex numbers.Subjects include light as wave motion; superposition of wave motions; electromagnetic waves; interaction of light and matter; velocities and scattering of light; polarized light and dielectric boundarie

  1. Optical Fibre Bundle

    CERN Multimedia

    These are sample fibre optic cables which are used for networking. Optical fibers are widely used in fiber-optic communications, where they permit transmission over longer distances and at higher bandwidths (data rates) than wire cables. Fibers are used instead of metal wires because signals travel along them with less loss and are also immune to electromagnetic interference. This is useful for somewhere like CERN where magnets with their highly powerful magnetic fields could pose a problem.

  2. Determination of optical constants and nonlinear optical coefficients ...

    Indian Academy of Sciences (India)

    −7 cm2/W and nonlinear absorption coefficient, β = 6.31×10. −3 cm/W. Optical limiting characteris- tics of the dye-doped polymer film was studied. The result reveals that Violet 1 can be a promising material for optical limiting applications. Keywords. Absorption spectra; nonlinear optics; optical constants; optical limiting.

  3. Overview of optical microscopy and optical microspectroscopy

    Science.gov (United States)

    Ager, Joel W.

    1998-11-01

    Optical microscopy has historically been a major tool for semiconductor inspection. As the ULSI design rule continues to decline to 0.25 μm and below, standard optical microscopy methods will arrive at their resolution limit. In the first part of this paper an overview of currently used optical microscopy techniques will be given. The resolution limit for optical imaging will be discussed, and novel methods for increasing resolution, including deep UV microscopy and confocal laser microscopy, will be presented. The second part of the paper will discuss an emerging technology for contamination analysis in semiconductor processing, microspectroscopy. Three topics in this area will be discussed with an emphasis on applications to off-line defect identification in process development: (1) micro-Raman spectroscopy, (2) micro-fluorescence or micro-photoluminescence spectroscopy, and (3) micro-reflectivity. It will be shown that these microspectroscopy methods can provide composition information for defects down to 1 μm in size that is not accessible through the more commonly used methods such as scanning electron microscopy with energy dispersive spectroscopy (SEM/EDS) and scanning Auger microscopy. Classes of defects where optical micro-spectroscopy methods are useful include ceramic particles, thin films of organic material, and dielectric films.

  4. Fingerprint fake detection by optical coherence tomography

    Science.gov (United States)

    Meissner, Sven; Breithaupt, Ralph; Koch, Edmund

    2013-03-01

    The most established technique for the identification at biometric access control systems is the human fingerprint. While every human fingerprint is unique, fingerprints can be faked very easily by using thin layer fakes. Because commercial fingerprint scanners use only a two-dimensional image acquisition of the finger surface, they can only hardly differentiate between real fingerprints and fingerprint fakes applied on thin layer materials. A Swept Source OCT system with an A-line rate of 20 kHz and a lateral and axial resolution of approximately 13 μm, a centre wavelength of 1320 nm and a band width of 120 nm (FWHM) was used to acquire fingerprints and finger tips with overlying fakes. Three-dimensional volume stacks with dimensions of 4.5 mm x 4 mm x 2 mm were acquired. The layering arrangement of the imaged finger tips and faked finger tips was analyzed and subsequently classified into real and faked fingerprints. Additionally, sweat gland ducts were detected and consulted for the classification. The manual classification between real fingerprints and faked fingerprints results in almost 100 % correctness. The outer as well as the internal fingerprint can be recognized in all real human fingers, whereby this was not possible in the image stacks of the faked fingerprints. Furthermore, in all image stacks of real human fingers the sweat gland ducts were detected. The number of sweat gland ducts differs between the test persons. The typical helix shape of the ducts was observed. In contrast, in images of faked fingerprints we observe abnormal layer arrangements and no sweat gland ducts connecting the papillae of the outer fingerprint and the internal fingerprint. We demonstrated that OCT is a very useful tool to enhance the performance of biometric control systems concerning attacks by thin layer fingerprint fakes.

  5. LSST Camera Optics Design

    Energy Technology Data Exchange (ETDEWEB)

    Riot, V J; Olivier, S; Bauman, B; Pratuch, S; Seppala, L; Gilmore, D; Ku, J; Nordby, M; Foss, M; Antilogus, P; Morgado, N

    2012-05-24

    The Large Synoptic Survey Telescope (LSST) uses a novel, three-mirror, telescope design feeding a camera system that includes a set of broad-band filters and three refractive corrector lenses to produce a flat field at the focal plane with a wide field of view. Optical design of the camera lenses and filters is integrated in with the optical design of telescope mirrors to optimize performance. We discuss the rationale for the LSST camera optics design, describe the methodology for fabricating, coating, mounting and testing the lenses and filters, and present the results of detailed analyses demonstrating that the camera optics will meet their performance goals.

  6. Surface optical vortices

    Science.gov (United States)

    Lembessis, V. E.; Babiker, M.; Andrews, D. L.

    2009-01-01

    It is shown how the total internal reflection of orbital-angular-momentum-endowed light can lead to the generation of evanescent light possessing rotational properties in which the intensity distribution is firmly localized in the vicinity of the surface. The characteristics of these surface optical vortices depend on the form of the incident light and on the dielectric mismatch of the two media. The interference of surface optical vortices is shown to give rise to interesting phenomena, including pattern rotation akin to a surface optical Ferris wheel. Applications are envisaged to be in atom lithography, optical surface tweezers, and spanners.

  7. Optics for engineers

    CERN Document Server

    DiMarzio, Charles A

    2011-01-01

    This book is an excellent resource for teaching any student or scientist who needs to use optical systems. I particularly like the addition of MATLAB scripts and functions. Highly recommended.-Professor James C. Wyant, Dean of College of Optical Sciences, University of ArizonaHis book is clear, concise and highly readable. This is an excellent text.-Professor Changhuei Yang, California Institute of TechnologyAt last, a book on optics that is written with the practising engineer in mind. I have been teaching optics to engineers for many years and have often longed for a text aimed at my student

  8. Interactive virtual optical laboratories

    Science.gov (United States)

    Liu, Xuan; Yang, Yi

    2017-08-01

    Laboratory experiences are essential for optics education. However, college students have limited access to advanced optical equipment that is generally expensive and complicated. Hence there is a need for innovative solutions to expose students to advanced optics laboratories. Here we describe a novel approach, interactive virtual optical laboratory (IVOL) that allows unlimited number of students to participate the lab session remotely through internet, to improve laboratory education in photonics. Although students are not physically conducting the experiment, IVOL is designed to engage students, by actively involving students in the decision making process throughout the experiment.

  9. Ocean Optics Instrumentation Systems

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides instrumentation suites for a wide variety of measurements to characterize the ocean’s optical environment. These packages have been developed to...

  10. Optical engineering of diamond

    CERN Document Server

    Rabeau, James R

    2013-01-01

    This is the first comprehensive book on the engineering of diamond optical devices. It will give readers an up-to-date account of the properties of optical quality synthetic diamond (single crystal, nanodiamond and polycrystalline) and reviews the large and growing field of engineering of diamond-based optical devices, with applications in quantum computation, nano-imaging, high performance lasers, and biomedicine. It aims to provide scientists, engineers and physicists with a valuable resource and reference book for the design and performance of diamond-based optical devices.

  11. Bidirectional optical scattering facility

    Data.gov (United States)

    Federal Laboratory Consortium — Goniometric optical scatter instrument (GOSI)The bidirectional reflectance distribution function (BRDF) quantifies the angular distribution of light scattered from a...

  12. Optics, light and lasers

    CERN Document Server

    Meschede, Dieter

    2008-01-01

    Starting from the concepts of classical optics, Optics, Light and Lasers introduces in detail the phenomena of linear and nonlinear light matter interaction, the properties of modern laser sources, and the concepts of quantum optics. Several examples taken from the scope of modern research are provided to emphasize the relevance of optics in current developments within science and technology. The text has been written for newcomers to the topic and benefits from the author's ability to explain difficult sequences and effects in a straightforward and easily comprehensible way. To this second, c

  13. Elementary wave optics

    CERN Document Server

    Webb, Robert H

    2005-01-01

    This undergraduate textbook presents thorough coverage of the standard topics of classical optics and optical instrument design; it also offers significant details regarding the concepts of modern optics. Its survey of the mathematical tools of optics grants students insights into the physical principles of quantum mechanics.Two principal concepts occur throughout: a treatment of scattering from real scatterers (leading to Huygens' principles, diffraction theory, the index of refraction, and related topics); and the difference between coherent and noncoherent wave phenomena. Examinations of su

  14. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  15. Optical network democratization.

    Science.gov (United States)

    Nejabati, Reza; Peng, Shuping; Simeonidou, Dimitra

    2016-03-06

    The current Internet infrastructure is not able to support independent evolution and innovation at physical and network layer functionalities, protocols and services, while at same time supporting the increasing bandwidth demands of evolving and heterogeneous applications. This paper addresses this problem by proposing a completely democratized optical network infrastructure. It introduces the novel concepts of the optical white box and bare metal optical switch as key technology enablers for democratizing optical networks. These are programmable optical switches whose hardware is loosely connected internally and is completely separated from their control software. To alleviate their complexity, a multi-dimensional abstraction mechanism using software-defined network technology is proposed. It creates a universal model of the proposed switches without exposing their technological details. It also enables a conventional network programmer to develop network applications for control of the optical network without specific technical knowledge of the physical layer. Furthermore, a novel optical network virtualization mechanism is proposed, enabling the composition and operation of multiple coexisting and application-specific virtual optical networks sharing the same physical infrastructure. Finally, the optical white box and the abstraction mechanism are experimentally evaluated, while the virtualization mechanism is evaluated with simulation. © 2016 The Author(s).

  16. Intelligent Optical Systems Using Adaptive Optics

    Science.gov (United States)

    Clark, Natalie

    2012-01-01

    Until recently, the phrase adaptive optics generally conjured images of large deformable mirrors being integrated into telescopes to compensate for atmospheric turbulence. However, the development of smaller, cheaper devices has sparked interest for other aerospace and commercial applications. Variable focal length lenses, liquid crystal spatial light modulators, tunable filters, phase compensators, polarization compensation, and deformable mirrors are becoming increasingly useful for other imaging applications including guidance navigation and control (GNC), coronagraphs, foveated imaging, situational awareness, autonomous rendezvous and docking, non-mechanical zoom, phase diversity, and enhanced multi-spectral imaging. The active components presented here allow flexibility in the optical design, increasing performance. In addition, the intelligent optical systems presented offer advantages in size and weight and radiation tolerance.

  17. Multimode optical fiber

    Science.gov (United States)

    Bigot-Astruc, Marianne; Molin, Denis; Sillard, Pierre

    2014-11-04

    A depressed graded-index multimode optical fiber includes a central core, an inner depressed cladding, a depressed trench, an outer depressed cladding, and an outer cladding. The central core has an alpha-index profile. The depressed claddings limit the impact of leaky modes on optical-fiber performance characteristics (e.g., bandwidth, core size, and/or numerical aperture).

  18. Touch screens go optical

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Jakobsen, Michael Linde; Pedersen, Henrik Chresten

    2012-01-01

    A simple optical implementation of a touch screen is made possible by disrupting the total internal reflection in a 2D waveguide.......A simple optical implementation of a touch screen is made possible by disrupting the total internal reflection in a 2D waveguide....

  19. Torque and optical traps

    African Journals Online (AJOL)

    STORAGESEVER

    2008-12-29

    Dec 29, 2008 ... Optical traps are an important tool for research in the field of single molecule biophysics. Recent advances in optical trapping have extended their functionality from simple linear manipulation and measurement of forces, to now the ability to rotate objects and measure torques. This mini review summarizes ...

  20. Genetically determined optic neuropathies

    DEFF Research Database (Denmark)

    Milea, Dan; Amati-Bonneau, Patrizia; Reynier, Pascal

    2010-01-01

    The present review focuses on recent advances in the knowledge of hereditary optic neuropathies resulting from retinal ganglion cell degeneration, mostly due to mitochondrial dysfunctions.......The present review focuses on recent advances in the knowledge of hereditary optic neuropathies resulting from retinal ganglion cell degeneration, mostly due to mitochondrial dysfunctions....

  1. Isolated optic nerve pseudotumour

    International Nuclear Information System (INIS)

    Patankar, T.; Prasad, S.; Krishnan, A.; Laxminarayan, R.

    2000-01-01

    Isolated optic nerve involvement by the idiopathic inflammatory process is a rare finding and very few reports are available. Here a case of an isolated optic nerve inflammatory pseudotumour presenting with gradually progressive unilateral loss of vision is described. It showed dramatic response to a trial of steroids and its differential diagnoses are discussed. Copyright (1999) Blackwell Science Pty Ltd

  2. Electromagnetics and optics

    National Research Council Canada - National Science Library

    Kriezis, E. E; Chrissoulidis, D. P; Papagiannakis, A. G

    1992-01-01

    ..., since light is a high-frequency electromagnetic radiation. Although both electromagnetics and optics are their common origin is only superficially realised physics or electrical engineering. Deeper physical by treating electromagnetics and optics in parallel thus enlightening the natural link between them. By presenting principles, theory a...

  3. Stochastic singular optics

    CSIR Research Space (South Africa)

    Roux, FS

    2013-09-01

    Full Text Available Roux Presented at the International Conference on Correlation Optics 2013 Chernivtsi, Ukraine 18-20 September 2013 CSIR National Laser Centre, Pretoria, South Africa – p. 1/24 Contents ⊲ Defining Stochastic Singular Optics (SSO) ⊲ Tools of Stochastic...

  4. Stitching in optical processors

    Science.gov (United States)

    Caulfield, H. John

    2001-12-01

    Optical processing is supposed to be advantageous in very big problems, because it can handle those problems with minimal spatial and temporal complexity. What happens, though at the other extreme, where the problem is too big to be input into the optical system? I offer some preliminary thoughts here.

  5. Fiber optic hydrophone

    Science.gov (United States)

    Kuzmenko, P.J.; Davis, D.T.

    1994-05-10

    A miniature fiber optic hydrophone based on the principles of a Fabry-Perot interferometer is disclosed. The hydrophone, in one embodiment, includes a body having a shaped flexible bladder at one end which defines a volume containing air or suitable gas, and including a membrane disposed adjacent a vent. An optical fiber extends into the body with one end terminating in spaced relation to the membrane. Acoustic waves in the water that impinge on the bladder cause the pressure of the volume therein to vary causing the membrane to deflect and modulate the reflectivity of the Fabry-Perot cavity formed by the membrane surface and the cleaved end of the optical fiber disposed adjacent to the membrane. When the light is transmitted down the optical fiber, the reflected signal is amplitude modulated by the incident acoustic wave. Another embodiment utilizes a fluid filled volume within which the fiber optic extends. 2 figures.

  6. Elements of quantum optics

    CERN Document Server

    Meystre, Pierre

    2007-01-01

    Elements of Quantum Optics gives a self-contained and broad coverage of the basic elements necessary to understand and carry out research in laser physics and quantum optics, including a review of basic quantum mechanics and pedagogical introductions to system-reservoir interactions and to second quantization. The text reveals the close connection between many seemingly unrelated topics, such as probe absorption, four-wave mixing, optical instabilities, resonance fluorescence and squeezing. It also comprises discussions of cavity quantum electrodynamics and atom optics. The 4th edition includes a new chapter on quantum entanglement and quantum information, as well as added discussions of the quantum beam splitter, electromagnetically induced transparency, slow light, and the input-output formalism needed to understand many problems in quantum optics. It also provides an expanded treatment of the minimum-coupling Hamiltonian and a simple derivation of the Gross-Pitaevskii equation, an important gateway to rese...

  7. Optically Anomalous Crystals

    CERN Document Server

    Shtukenberg, Alexander; Kahr, Bart

    2007-01-01

    Optical anomalies in crystals are puzzles that collectively constituted the greatest unsolved problems in crystallography in the 19th Century. The most common anomaly is a discrepancy between a crystal’s symmetry as determined by its shape or by X-ray analysis, and that determined by monitoring the polarization state of traversing light. These discrepancies were perceived as a great impediment to the development of the sciences of crystals on the basis of Curie’s Symmetry Principle, the grand organizing idea in the physical sciences to emerge in the latter half of the 19th Century. Optically Anomalous Crystals begins with an historical introduction covering the contributions of Brewster, Biot, Mallard, Brauns, Tamman, and many other distinguished crystallographers. From this follows a tutorial in crystal optics. Further chapters discuss the two main mechanisms of optical dissymmetry: 1. the piezo-optic effect, and 2. the kinetic ordering of atoms. The text then tackles complex, inhomogeneous crystals, and...

  8. Introduction to Optics

    CERN Document Server

    Chartier, Germain

    2005-01-01

    Since the discovery of the laser in 1960 and optical fibers in 1970, optics has undergone dramatic changes that accentuate its multi-disciplinary character. This text covers essential concepts and reports the key developments and progress in current knowledge in the field. Inspired by the style of Richard Feynman, the method of presentation emphasizes "telling" optics, rather than deducing it from fundamental laws, as well as tactfully using mathematical tools so as not to obscure the physical phenomena of interest. For its excellent teaching approach, the book received the Arnulf-Francon Award of the French Optical Society. The concepts are formulated in a way such that the necessary mathematical tools do not hinder comprehension of the phenomena. Global in vision, the book can also be used as a reference. In addition to the traditional aspects of optics, it includes the tools and methods currently used by researchers and engineers, as well as explanation and implications of the most recent developments.

  9. Nonlinear optics and photonics

    CERN Document Server

    He, Guang S

    2015-01-01

    This book provides a comprehensive presentation on most of the major topics in nonlinear optics and photonics, with equal emphasis on principles, experiments, techniques, and applications. It covers many major new topics including optical solitons, multi-photon effects, nonlinear photoelectric effects, fast and slow light , and Terahertz photonics. Chapters 1-10 present the fundamentals of modern nonlinear optics, and could be used as a textbook with problems provided at the end of each chapter. Chapters 11-17 cover the more advanced topics of techniques and applications of nonlinear optics and photonics, serving as a highly informative reference for researchers and experts working in related areas. There are also 16 pages of color photographs to illustrate the visual appearances of some typical nonlinear optical effects and phenomena. The book could be adopted as a textbook for both undergraduates and graduate students, and serve as a useful reference work for researchers and experts in the fields of physics...

  10. The Optics of Bruising

    Science.gov (United States)

    Randeberg, Lise Lyngsnes; Skallerud, Bjørn; Langlois, Neil E. I.; Haugen, Olav Anton; Svaasand, Lars Othar

    Forensic medicine is a field of medicine where technology plays an increasingly important role in securing and evaluating evidence in, for example, child abuse cases and cases of domestic violence. Methods from chemistry and biological sciences have found a wide application within forensic medicine. Optical technologies like microscopy are also widely used. Despite this, in vivo or post mortem optical diagnostics by spectroscopy have traditionally not had an important role in clinical or forensic examinations. Forensic medical optics as a field might include all kinds of optical analysis for use within forensic science. This includes everything from microscopic techniques to methods for examination of evidence from a crime scene. This chapter will, however, focus on the use of optical diagnostics for examining skin, with a focus on identification, characterization and age determination of minor traumatic injuries like skin bruises.

  11. Optical analogy. Synthesis report

    International Nuclear Information System (INIS)

    1965-01-01

    The authors report the study of conditions under which light attenuation (reflection, diffusion, absorption) and the attenuation of some radiations (notably thermal neutrons) can be described with analogical calculations. The analogy between light physical properties and neutron properties is not searched for, but the analogy between their attenuation characteristics. After having discussed this possible analogy, they propose a mathematical formulation of neutron and optical phenomena which could theoretically justify the optical analogy. The second part reports a more practical study of optics problems such as the study of simple optics materials and illumination measurements, or more precisely the study of angular distributions of optical reflections, a determination of such angular distributions, and an experimental determination of the albedo

  12. Fiber optics standard dictionary

    CERN Document Server

    Weik, Martin H

    1997-01-01

    Fiber Optics Vocabulary Development In 1979, the National Communications System published Technical InfonnationBulle­ tin TB 79-1, Vocabulary for Fiber Optics and Lightwave Communications, written by this author. Based on a draft prepared by this author, the National Communications System published Federal Standard FED-STD-1037, Glossary of Telecommunications Terms, in 1980 with no fiber optics tenns. In 1981, the first edition of this dictionary was published under the title Fiber Optics and Lightwave Communications Standard Dictionary. In 1982, the then National Bureau of Standards, now the National Institute of Standards and Technology, published NBS Handbook 140, Optical Waveguide Communications Glossary, which was also published by the General Services Admin­ istration as PB82-166257 under the same title. Also in 1982, Dynamic Systems, Inc. , Fiberoptic Sensor Technology Handbook, co-authored and edited by published the this author, with an extensive Fiberoptic Sensors Glossary. In 1989, the handbook w...

  13. Fiber optic hydrophone

    Science.gov (United States)

    Kuzmenko, Paul J.; Davis, Donald T.

    1994-01-01

    A miniature fiber optic hydrophone based on the principles of a Fabry-Perot interferometer. The hydrophone, in one embodiment, includes a body having a shaped flexible bladder at one end which defines a volume containing air or suitable gas, and including a membrane disposed adjacent a vent. An optic fiber extends into the body with one end terminating in spaced relation to the membrane. Acoustic waves in the water that impinge on the bladder cause the pressure of the volume therein to vary causing the membrane to deflect and modulate the reflectivity of the Fabry-Perot cavity formed by the membrane surface and the cleaved end of the optical fiber disposed adjacent to the membrane. When the light is transmitted down the optical fiber, the reflected signal is amplitude modulated by the incident acoustic wave. Another embodiment utilizes a fluid filled volume within which the fiber optic extends.

  14. Optical computer switching network

    Science.gov (United States)

    Clymer, B.; Collins, S. A., Jr.

    1985-01-01

    The design for an optical switching system for minicomputers that uses an optical spatial light modulator such as a Hughes liquid crystal light valve is presented. The switching system is designed to connect 80 minicomputers coupled to the switching system by optical fibers. The system has two major parts: the connection system that connects the data lines by which the computers communicate via a two-dimensional optical matrix array and the control system that controls which computers are connected. The basic system, the matrix-based connecting system, and some of the optical components to be used are described. Finally, the details of the control system are given and illustrated with a discussion of timing.

  15. Structural, optical spectroscopy, optical conductivity, dielectric ...

    Indian Academy of Sciences (India)

    13

    different methods of preparation [36-41]. The electrical insulator materials with low refractive index and low absorption are needed for various optical devices, such as low loss waveguides, resonators, photonic crystals, distributed Bragg reflectors, light-emitting diodes, passive splitters, biosensors, attenuators and filters ...

  16. Integrated-optics-based optical coherence tomography

    NARCIS (Netherlands)

    Nguyen, D.V.

    2013-01-01

    Optical coherence tomography (OCT) is a high resolution, imaging technique that has developed over the last 20 years from a complicated laboratory setup into a ready-to-use commercially available device. Instead of using electronic time gating as being used by ultrasound (US) imaging, in OCT, the

  17. Optics equations for aero-optical analysis

    Science.gov (United States)

    Sutton, George W.; Pond, John E.

    2011-05-01

    Aero-optical effects occur around moving air vehicles and impact passive imaging or active systems. The air flow around the vehicle is compressed, and often there is a turbulent shear and/or boundary layer both of which cause variations in the index of refraction. Examples of these are reconnaissance aircraft, the Stratospheric Observatory for Infrared Optics (SOFIA), and optically homing hypersonic interceptors. In other applications, a laser beam can be formed within the vehicle, and projected outward and focused on an object. These include the Airborne Laser Laboratory, Airborne Laser and the Airborne Tactical Laser. There are many compressible fluid mechanics computer programs that can predict the air density distribution of the surrounding flow field including density fluctuations in turbulent shear and/or boundary layers. It is necessary for the physical optics to be used to predict the properties of the ensuing image plane intensity distribution, whether passive or active. These include the time-averaged image blur circle and instantaneous realizations. (Ray tracing is a poor approximation that gives erroneous results for small aberrations.)

  18. Miniature Optical Isolator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — To address NASA's need for compact optical isolators, Physical Optics Corporation (POC) proposes to continue the development of a new Miniature Optical Isolator...

  19. 50 years of nonlinear optics

    International Nuclear Information System (INIS)

    Shen Yuanrang

    2011-01-01

    This article presents a brief introduction to the birth and early investigations of nonlinear optics, such as second harmonic generation,sum and difference frequency generation, stimulated Raman scattering,and self-action of light etc. Several important research achievements and applications of nonlinear optics are presented as well, including nonlinear optical spectroscopy, phase conjugation and adaptive optics, coherent nonlinear optics, and high-order harmonic generation. In the end, current and future research topics in nonlinear optics are summarized. (authors)

  20. Optical thin film devices

    Science.gov (United States)

    Mao, Shuzheng

    1991-11-01

    Thin film devices are applied to almost all modern scientific instruments, and these devices, especially optical thin film devices, play an essential role in the performances of the instruments, therefore, they are attracting more and more attention. Now there are numerous kinds of thin film devices and their applications are very diversified. The 300-page book, 'Thin Film Device and Applications,' by Prof. K. L. Chopra gives some general ideas, and my paper also outlines the designs, fabrication, and applications of some optical thin film devices made in my laboratory. Optical thin film devices have been greatly developed in the recent decades. Prof. A. Thelan has given a number of papers on the theory and techniques, Prof. H. A. Macleod's book, 'Thin Film Optical Filters,' has concisely concluded the important concepts of optical thin film devices, and Prof. J. A. Dobrowobski has proposed many successful designs for optical thin film devices. Recently, fully-automatic plants make it easier to produce thin film devices with various spectrum requirements, and some companies, such as Balzers, Leybold AG, Satis Vacuum AG, etc., have manufactured such kinds of coating plants for research or mass-production, and the successful example is the production of multilayer antireflection coatings with high stability and reproducibility. Therefore, it could be said that the design of optical thin film devices and coating plants is quite mature. However, we cannot expect that every problem has been solved, the R&D work still continues, the competition still continues, and new design concepts, new techniques, and new film materials are continually developed. Meanwhile, the high-price of fully-automatic coating plants makes unpopular, and automatic design of coating stacks is only the technique for optimizing the manual design according to the physical concepts and experience, in addition, not only the optical system, but also working environment should be taken into account when

  1. Optical electromagnetic radiation detector

    International Nuclear Information System (INIS)

    Miceli, W. J.; Ludman, J. E.

    1985-01-01

    An optical electromagnetic radiation detector having a probe for receiving nearby electromagnetic radiation. The probe includes a loop antenna connected to a pair of transparent electrodes deposited on the end surfaces of an electro-optic Fabry-Perot interferometer. When the loop antenna picks up the presence of electromagnetic radiation, a voltage will be developed across the crystal of the electro-optic Fabry-Perot interferometer thereby changing the optical length of the interferometer. A beam of light from a remote location is transmitted through an optical fiber onto the Fabry-Perot interferometer. The change in optical length of the Fabry-Perot interferometer alters the intensity of the beam of light as it is reflected from the Fabry-Perot interferometer back through the optical fiber to the remote location. A beamsplitter directs this reflected beam of light onto an intensity detector in order to provide an output indicative of the variations in intensity. The variations in intensity are directly related to the strength of the electromagnetic radiation received by the loop antenna

  2. Optical fiber spectrophotometer

    International Nuclear Information System (INIS)

    Zhuang Weixin; Tian Guocheng; Ye Guoan; Zhou Zhihong; Cheng Weiwei; Huang Lifeng; Liu Suying; Tang Yanji; Hu Jingxin; Zhao Yonggang

    1998-12-01

    A method called 'Two Arm's Photo out and Electricity Send-back' is introduced. UV-365 UV/VIS/NIR spectrophotometer has been reequipped by this way with 5 meters long optical fiber. Another method called 'One Arm's Photo out and Photo Send-back' is also introduced. λ 19 UV/VIS/NIR spectrophotometer has been reequipped by this way with 10 meters long optical fiber. Optical fiber spectrophotometer can work as its main set. So it is particularly applicable to radio activity work

  3. The ANTARES Optical Module

    CERN Document Server

    Amram, P; Anvar, S; Ardellier-Desages, F E; Aslanides, Elie; Aubert, Jean-Jacques; Azoulay, R; Bailey, D; Basa, S; Battaglieri, M; Bellotti, R; Benhammou, Ya; Bernard, F; Berthier, R; Bertin, V; Billault, M; Blaes, R; Bland, R W; Blondeau, F; De Botton, N R; Boulesteix, J; Brooks, B; Brunner, J; Cafagna, F; Calzas, A; Capone, A; Caponetto, L; Cârloganu, C; Carmona, E; Carr, J; Carton, P H; Cartwright, S L; Cassol, F; Cecchini, S; Ciacio, F; Circella, M; Compere, C; Cooper, S; Coyle, P; Croquette, J; Cuneo, S; Danilov, M; Van Dantzig, R; De Marzo, C; De Vita, R; Deck, P; Destelle, J J; Dispau, G; Drougou, J F; Druillole, F; Engelen, J; Feinstein, F; Festy, D; Fopma, J; Gallone, J M; Giacomelli, G; Goret, P; Gosset, L G; Gournay, J F; Heijboer, A; Hernández-Rey, J J; Herrouin, G; Hubbard, John R; Jacquet, M; De Jong, M; Karolak, M; Kooijman, P M; Kouchner, A; Kudryavtsev, V A; Lachartre, D; Lafoux, H; Lamare, P; Languillat, J C; Laubier, L; Laugier, J P; Le Guen, Y; Le Provost, H; Le Van-Suu, A; Lemoine, L; Lo Nigro, L; Lo Presti, D; Loucatos, Sotirios S; Louis, F; Lyashuk, V I; Magnier, P; Marcelin, M; Margiotta, A; Massol, A; Masullo, R; Mazéas, F; Mazeau, B; Mazure, A; McMillan, J E; Michel, J L; Migneco, E; Millot, C; Mols, P; Montanet, François; Montaruli, T; Morel, J P; Moscoso, L; Navas, S; Nezri, E; Nooren, G J L; Oberski, J; Olivetto, C; Oppelt-pohl, A; Palanque-Delabrouille, Nathalie; Payre, P; Perrin, P; Petruccetti, M; Petta, P; Piattelli, P; Poinsignon, J; Popa, V; Potheau, R; Queinec, Y; Racca, C; Raia, G; Randazzo, N; Rethore, F; Riccobene, G; Ricol, J S; Ripani, M; Roca-Blay, V; Rolin, J F; Rostovtsev, A A; Russo, G V; Sacquin, Yu; Salusti, E; Schuller, J P; Schuster, W; Soirat, J P; Suvorova, O; Spooner, N J C; Spurio, M; Stolarczyk, T; Stubert, D; Taiuti, M; Tao, Charling; Tayalati, Y; Thompson, L F; Tilav, S; Triay, R; Valente, V; Varlamov, I; Vaudaine, G; Vernin, P; De Witt-Huberts, P K A; De Wolf, E; Zakharov, V; Zavatarelli, S; De Dios-Zornoza-Gomez, Juan; Zúñiga, J

    2002-01-01

    The ANTARES collaboration is building a deep sea neutrino telescope in the Mediterranean Sea. This detector will cover a sensitive area of typically 0.1 km-squared and will be equipped with about 1000 optical modules. Each of these optical modules consists of a large area photomultiplier and its associated electronics housed in a pressure resistant glass sphere. The design of the ANTARES optical module, which is a key element of the detector, has been finalized following extensive R & D studies and is reviewed here in detail.

  4. Scalable optical quantum computer

    International Nuclear Information System (INIS)

    Manykin, E A; Mel'nichenko, E V

    2014-01-01

    A way of designing a scalable optical quantum computer based on the photon echo effect is proposed. Individual rare earth ions Pr 3+ , regularly located in the lattice of the orthosilicate (Y 2 SiO 5 ) crystal, are suggested to be used as optical qubits. Operations with qubits are performed using coherent and incoherent laser pulses. The operation protocol includes both the method of measurement-based quantum computations and the technique of optical computations. Modern hybrid photon echo protocols, which provide a sufficient quantum efficiency when reading recorded states, are considered as most promising for quantum computations and communications. (quantum computer)

  5. Isolated Optic Disc Tuberculosis

    Science.gov (United States)

    Mansour, Ahmad M.; Tabbara, Khalid F.; Tabbarah, Zuhair

    2015-01-01

    We present a healthy male subject who developed progressive visual loss in the left eye initially diagnosed as optic neuritis. Upon suspicion of infectious etiology, testing was positive for tuberculosis. There were no signs or symptoms of active systemic tuberculosis infection. The patient responded swiftly to antimycobacterial therapy with return of vision and resolution of disc swelling. Positive purified protein derivative skin test, negative chest radiograph, negative systemic workup, negative workup for other causes of unilateral optic neuritis and quick response to mycobacterial therapy reaffirm the entity of isolated optic disc tuberculosis similar to isolated choroidal tuberculosis without systemic manifestation. PMID:26483675

  6. Isolated Optic Disc Tuberculosis

    Directory of Open Access Journals (Sweden)

    Ahmad M. Mansour

    2015-09-01

    Full Text Available We present a healthy male subject who developed progressive visual loss in the left eye initially diagnosed as optic neuritis. Upon suspicion of infectious etiology, testing was positive for tuberculosis. There were no signs or symptoms of active systemic tuberculosis infection. The patient responded swiftly to antimycobacterial therapy with return of vision and resolution of disc swelling. Positive purified protein derivative skin test, negative chest radiograph, negative systemic workup, negative workup for other causes of unilateral optic neuritis and quick response to mycobacterial therapy reaffirm the entity of isolated optic disc tuberculosis similar to isolated choroidal tuberculosis without systemic manifestation.

  7. Wireless optical telecommunications

    CERN Document Server

    Bouchet, Olivier

    2013-01-01

    Wireless optical communication refers to communication based on the unguided propagation of optical waves. The past 30 years have seen significant improvements in this technique - a wireless communication solution for the current millennium - that offers an alternative to radio systems; a technique that could gain attractiveness due to recent concerns regarding the potential effects of radiofrequency waves on human health.The aim of this book is to look at the free space optics that are already used for the exchange of current information; its many benefits, such as incorporating chan

  8. Microstructured polymer optical fibres

    CERN Document Server

    Large, Maryanne; Barton, Geoff; van Eijkelenborg, Martijn A

    2008-01-01

    Microstructured Polymer Optical Fibres describes the optical properties of microstructured fibres, how they are made and modelled, and outlines some potential applications. These applications include areas where polymer fibres are already used, such as high-data rate transmission for Fibre-to-the Home or within cars, as well as completely new areas such as the photonic bandgap transmission of ""difficult"" wavelengths. Emphasising a conceptual understanding of the underlying physics, Microstructured Polymer Optical Fibres is clearly written, and includes numerous illustrations. It provides an

  9. POLARISATION PRESERVING OPTICAL FIBRE

    DEFF Research Database (Denmark)

    2000-01-01

    A micro-structured optical fibre having a cladding comprising a number of elements having a non-circular cross-section. Each element has at least one part extending outside a circle having the same cross-sectional area as the element. These extending parts are directed in the same direction....... This cladding structure provides polarisation preserving properties to the optical fibre. Optical fibres using this technology may have claddings with elements placed non-periodically as well as in a two-dimensional periodic lattice - such as cladding providing Photonic Band Gap (PBG) effects....

  10. Quantum optics for engineers

    CERN Document Server

    Duarte, FJ

    2013-01-01

    Quantum Optics for Engineers provides a transparent and methodical introduction to quantum optics via the Dirac's bra-ket notation with an emphasis on practical applications and basic aspects of quantum mechanics such as Heisenberg's uncertainty principle and Schrodinger's equation. Self-contained and using mainly first-year calculus and algebra tools, the book:Illustrates the interferometric quantum origin of fundamental optical principles such as diffraction, refraction, and reflectionProvides a transparent introduction, via Dirac's notation, to the probability amplitude of quantum entanglem

  11. Theoretical Optics An Introduction

    CERN Document Server

    Römer, Hartmann

    2004-01-01

    Starting from basic electrodynamics, this volume provides a solid, yet concise introduction to theoretical optics, containing topics such as nonlinear optics, light-matter interaction, and modern topics in quantum optics, including entanglement, cryptography, and quantum computation. The author, with many years of experience in teaching and research, goes way beyond the scope of traditional lectures, enabling readers to keep up with the current state of knowledge. Both content and presentation make it essential reading for graduate and phD students as well as a valuable reference for researche

  12. Handbook of optical microcavities

    CERN Document Server

    Choi, Anthony H W

    2014-01-01

    An optical cavity confines light within its structure and constitutes an integral part of a laser device. Unlike traditional gas lasers, semiconductor lasers are invariably much smaller in dimensions, making optical confinement more critical than ever. In this book, modern methods that control and manipulate light at the micrometer and nanometer scales by using a variety of cavity geometries and demonstrate optical resonance from ultra-violet (UV) to infra-red (IR) bands across multiple material platforms are explored. The book has a comprehensive collection of chapters that cover a wide range

  13. Optics and children

    International Nuclear Information System (INIS)

    Costa, Manuel F M; De Campos, J Ayres; Lira, Madalena; Franco, Sandra; Vazquez-Dorrio, Jose B

    2011-01-01

    Light and Optics are subjects that 'naturally' attracts the interest and sympathy of children even from very early ages. In this communication, we present a series of experiments and support material designed in this hands-on perspective, to be used to introduce the study of light and optics to kindergarten and early basic school students. Our hands-on investigative approach leads the students, aged 4 to 10 years, to observe the experiment and discover themselves, in a critical and active way, different aspects of light and optics. Preparing funny eye catching situations and experiments predispose the children to work, effectively, enjoying themselves while building up their self-confidence.

  14. Tuned optical cavity magnetometer

    Science.gov (United States)

    Okandan, Murat; Schwindt, Peter

    2010-11-02

    An atomic magnetometer is disclosed which utilizes an optical cavity formed from a grating and a mirror, with a vapor cell containing an alkali metal vapor located inside the optical cavity. Lasers are used to magnetically polarize the alkali metal vapor and to probe the vapor and generate a diffracted laser beam which can be used to sense a magnetic field. Electrostatic actuators can be used in the magnetometer for positioning of the mirror, or for modulation thereof. Another optical cavity can also be formed from the mirror and a second grating for sensing, adjusting, or stabilizing the position of the mirror.

  15. The ANTARES optical module

    Energy Technology Data Exchange (ETDEWEB)

    Amram, P.; Anghinolfi, M.; Anvar, S.; Ardellier-Desages, F.E.; Aslanides, E.; Aubert, J.-J.; Azoulay, R.; Bailey, D.; Basa, S.; Battaglieri, M.; Bellotti, R.; Benhammou, Y.; Bernard, F.; Berthier, R.; Bertin, V.; Billault, M.; Blaes, R.; Bland, R.W.; Blondeau, F.; Botton, N. de; Boulesteix, J.; Brooks, C.B.; Brunner, J.; Cafagna, F.; Calzas, A.; Capone, A.; Caponetto, L.; Carloganu, C.; Carmona, E.; Carr, J.; Carton, P.-H.; Cartwright, S.L.; Cassol, F.; Cecchini, S.; Ciacio, F.; Circella, M.; Compere, C.; Cooper, S.; Coyle, P.; Croquette, J.; Cuneo, S.; Danilov, M.; Dantzig, R. van; De Marzo, C.; DeVita, R.; Deck, P.; Destelle, J.-J.; Dispau, G.; Drougou, J.F.; Druillole, F.; Engelen, J.; Feinstein, F.; Festy, D.; Fopma, J.; Gallone, J.-M.; Giacomelli, G.; Goret, P.; Gosset, L.; Gournay, J.-F.; Heijboer, A.; Hernandez-Rey, J.J.; Herrouin, G.; Hubbard, J.R.; Jaquet, M.; Jong, M. de; Karolak, M.; Kooijman, P.; Kouchner, A.; Kudryavtsev, V.A.; Lachartre, D.; Lafoux, H. E-mail: lafoux@cea.fr; Lamare, P.; Languillat, J.-C.; Laubier, L.; Laugier, J.-P.; Le Guen, Y.; Le Provost, H.; Le Van Suu, A.; Lemoine, L.; Lo Nigro, L.; Lo Presti, D.; Loucatos, S.; Louis, F.; Lyashuk, V.; Magnier, P.; Marcelin, M.; Margiotta, A.; Massol, A.; Masullo, R.; Mazeas, F.; Mazeau, B.; Mazure, A.; McMillan, J.E.; Michel, J.L.; Migneco, E.; Millot, C.; Mols, P.; Montanet, F.; Montaruli, T.; Morel, J.P.; Moscoso, L.; Musumeci, M.; Navas, S.; Nezri, E.; Nooren, G.J.; Oberski, J.; Olivetto, C.; Oppelt-Pohl, A.; Palanque-Delabrouille, N.; Papaleo, R.; Payre, P.; Perrin, P.; Petruccetti, M.; Petta, C.; Piattelli, P.; Poinsignon, J.; Potheau, R.; Queinec, Y.; Racca, C.; Raia, G.; Randazzo, N.; Rethore, F.; Riccobene, G.; Ricol, J.-S.; Ripani, M.; Roca-Blay, V.; Rolin, J.F.; Rostovstev, A.; Russo, G.V.; Sacquin, Y.; Salusti, E.; Schuller, J.-P.; Schuster, W.; Soirat, J.-P.; Souvorova, O.; Spooner, N.J.C.; Spurio, M.; Stolarczyk, T.; Stubert, D.; Taiuti, M.; Tao, C.; Tayalati, Y.; Thompson, L.F.

    2002-05-21

    The ANTARES collaboration is building a deep sea neutrino telescope in the Mediterranean Sea. This detector will cover a sensitive area of typically 0.1 km{sup 2} and will be equipped with about 1000 optical modules. Each of these optical modules consists of a large area photomultiplier and its associated electronics housed in a pressure resistant glass sphere. The design of the ANTARES optical module, which is a key element of the detector, has been finalized following extensive R and D studies and is reviewed here in detail.

  16. Optical properties of solids

    CERN Document Server

    Wooten, Frederick

    1972-01-01

    Optical Properties of Solids covers the important concepts of intrinsic optical properties and photoelectric emission. The book starts by providing an introduction to the fundamental optical spectra of solids. The text then discusses Maxwell's equations and the dielectric function; absorption and dispersion; and the theory of free-electron metals. The quantum mechanical theory of direct and indirect transitions between bands; the applications of dispersion relations; and the derivation of an expression for the dielectric function in the self-consistent field approximation are also encompassed.

  17. Methods for globally treating silica optics to reduce optical damage

    Science.gov (United States)

    Miller, Philip Edward; Suratwala, Tayyab Ishaq; Bude, Jeffrey Devin; Shen, Nan; Steele, William Augustus; Laurence, Ted Alfred; Feit, Michael Dennis; Wong, Lana Louie

    2012-11-20

    A method for preventing damage caused by high intensity light sources to optical components includes annealing the optical component for a predetermined period. Another method includes etching the optical component in an etchant including fluoride and bi-fluoride ions. The method also includes ultrasonically agitating the etching solution during the process followed by rinsing of the optical component in a rinse bath.

  18. Optical computation based on nonlinear total reflectional optical ...

    Indian Academy of Sciences (India)

    All-optical parallel computation is the key technology in all-optical net [1]. It is also the essential part of the optical computer [2]. Optical computing was a hot research field in the 1980s. But this work was not progressed because of material limitations. [3]. It received attention again with its progression in the last decades.

  19. Realization of an optical interferometer based on holographic optics ...

    Indian Academy of Sciences (India)

    The paper describes a simple and cost effective method for the realization of an optical interferometer based on holographic optics, which use minimal bulk optical components. The optical arrangement in the proposed method involves a very simple alignment procedure and inexpensive holographic recording material is ...

  20. All-optical signal processing for optical packet switching [Invited

    Science.gov (United States)

    Geldenhuys, R.; Liu, Y.; Calabretta, N.; Hill, M. T.; Huijskens, F. M.; Khoe, G. D.; Dorren, H. J. S.

    2004-12-01

    We present three optical signal processing functional blocks that enable 1×N optical packet switching. An ultrafast asynchronous multioutput all-optical header processor is demonstrated with a terahertz optical asymmetric demultiplexer in combination with a header preprocessor. It is shown that self-induced polarization rotation can be used for both the header processor and the header preprocessor. The second functional block is optical buffering. This is shown with both a laser neural network and a recirculating buffer. Related to this is a three-state all-optical memory based on coupled lasers, which increases the number of possible output states of an optical packet switch.

  1. Electro-Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    2006-06-01

    In the Electro-Optical Characterization group, within the National Center for Photovoltaic's Measurements and Characterization Division, we use various electrical and optical experimental techniques to relate photovoltaic device performance to the methods and materials used to produce them. The types of information obtained by these techniques range from small-scale atomic-bonding information to large-scale macroscopic quantities such as optical constants and electron-transport properties. Accurate and timely measurement of the electro-optical properties as a function of device processing provides researchers and manufacturers with the knowledge needed to troubleshoot problems and develop the knowledge base necessary for reducing cost, maximizing efficiency, improving reliability, and enhancing manufacturability. We work collaboratively with you to solve materials- and device-related R&D problems. This sheet summarizes our primary techniques and capabilities.

  2. Problems in optics

    CERN Document Server

    Rousseau, Madeleine; Ter Haar, D

    1973-01-01

    This collection of problems and accompanying solutions provide the reader with a full introduction to physical optics. The subject coverage is fairly traditional, with chapters on interference and diffraction, and there is a general emphasis on spectroscopy.

  3. Optical lattices: Orbital dance

    Science.gov (United States)

    Lewenstein, Maciej; Liu, W. Vincent

    2011-02-01

    Emulating condensed-matter physics with ground-state atoms trapped in optical lattices has come a long way. But excite the atoms into higher orbital states, and a whole new world of exotic states appears.

  4. Optical tweezers: wideband microrheology

    International Nuclear Information System (INIS)

    Preece, Daryl; Gibson, Graham M; Padgett, Miles J; Warren, Rebecca; Cooper, Jonathan M; Tassieri, Manlio; Evans, R M L

    2011-01-01

    Microrheology is a branch of rheology having the same principles as conventional bulk rheology, but working on micron length scales and microlitre volumes. Optical tweezers have been successfully used with Newtonian fluids for rheological purposes such as determining fluid viscosity. Conversely, when optical tweezers are used to measure the viscoelastic properties of complex fluids the results are either limited to the material's high-frequency response, discarding important information related to the low-frequency behaviour, or they are supplemented by low-frequency measurements performed with different techniques, often without presenting an overlapping region of clear agreement between the sets of results. We present a simple experimental procedure to perform microrheological measurements over the widest frequency range possible with optical tweezers. A generalized Langevin equation is used to relate the frequency-dependent moduli of the complex fluid to the time-dependent trajectory of a probe particle as it flips between two optical traps that alternately switch on and off

  5. Optical fiber switch

    Science.gov (United States)

    Early, James W.; Lester, Charles S.

    2002-01-01

    Optical fiber switches operated by electrical activation of at least one laser light modulator through which laser light is directed into at least one polarizer are used for the sequential transport of laser light from a single laser into a plurality of optical fibers. In one embodiment of the invention, laser light from a single excitation laser is sequentially transported to a plurality of optical fibers which in turn transport the laser light to separate individual remotely located laser fuel ignitors. The invention can be operated electro-optically with no need for any mechanical or moving parts, or, alternatively, can be operated electro-mechanically. The invention can be used to switch either pulsed or continuous wave laser light.

  6. Simulating Optical Fibers.

    Science.gov (United States)

    Edgar, Dale

    1988-01-01

    Described is a demonstration of Snell's law using a laser beam and an optical fiber. Provided are the set-up method of the demonstration apparatus and some practical suggestions including "index matching" technique using vaseline. (YP)

  7. Electroabsorption optical modulator

    Science.gov (United States)

    Skogen, Erik J.

    2017-11-21

    An electroabsorption modulator incorporates waveguiding regions along the length of the modulator that include quantum wells where at least two of the regions have quantum wells with different bandgaps. In one embodiment of the invention, the regions are arranged such that the quantum wells have bandgaps with decreasing bandgap energy along the length of the modulator from the modulator's input to its output. The bandgap energy of the quantum wells may be decreased in discrete steps or continuously. Advantageously, such an arrangement better distributes the optical absorption as well as the carrier density along the length of the modulator. Further advantageously, the modulator may handle increased optical power as compared with prior art modulators of similar dimensions, which allows for improved link gain when the optical modulator is used in an analog optical communication link.

  8. Optical Polarizationin Biomedical Applications

    CERN Document Server

    Tuchin, Valery V; Zimnyakov, Dmitry A

    2006-01-01

    Optical Polarization in Biomedical Applications introduces key developments in optical polarization methods for quantitative studies of tissues, while presenting the theory of polarization transfer in a random medium as a basis for the quantitative description of polarized light interaction with tissues. This theory uses the modified transfer equation for Stokes parameters and predicts the polarization structure of multiple scattered optical fields. The backscattering polarization matrices (Jones matrix and Mueller matrix) important for noninvasive medical diagnostic are introduced. The text also describes a number of diagnostic techniques such as CW polarization imaging and spectroscopy, polarization microscopy and cytometry. As a new tool for medical diagnosis, optical coherent polarization tomography is analyzed. The monograph also covers a range of biomedical applications, among them cataract and glaucoma diagnostics, glucose sensing, and the detection of bacteria.

  9. Multiple beam optical processing

    Science.gov (United States)

    Gibbs, Hyatt M.; Peyghambarian, N.; Khitrova, G.; Koch, S.; Kostuk, R.; MacLeod, A.; Wagner, K.; Roude, D.; Warren, M.

    1989-12-01

    The objective of this effort was to develop optical processing technology required to implement high performance signal processing systems. The work concentrated on the evaluation and characterization of GaAs nonlinear etalons and methods of using these etalons in optical processing functions. Experiments included the implementation of a one bit adder using symbolic substitution, a pattern recognizer that can distinguish between simple three spot patterns, an associative memory which can discriminate against two different input objects, and an all optical compare and exchange module which can compare the magnitude of two digital input signals and make an appropriate exchange decision. These experiments, although rudimentary, may be extendable to larger scales upon further development of the optical processing technology.

  10. Towards Improved Optical Limiters

    National Research Council Canada - National Science Library

    Huffman, Peter

    2002-01-01

    .... The first approach was to synthesize and study soluble thallium phthalocyanines. Thallium, due to its proximity to lead and indium on the periodic table, should exhibit favorable optical limiting properties...

  11. Optical spark chamber

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    An optical spark chamber developed for use in the Omega spectrometer. On the left the supporting frame is exceptionally thin to allow low momentum particles to escape and be detected outside the magnetic field.

  12. Adaptive optics in ophthalmology

    Science.gov (United States)

    Iroshnikov, Nikita G.; Larichev, Andrey V.

    2006-09-01

    We present the experimental implementation of ophthalmic diagnostic systems with adaptive optics compensation of human eye aberration. The systems feature high speed operation and utilize deformable bimorph mirrors for wavefront correction. The results of aberration measurements and correction are discussed.

  13. Multimodal hyperspectral optical microscopy

    Science.gov (United States)

    Novikova, Irina V.; Smallwood, Chuck R.; Gong, Yu; Hu, Dehong; Hendricks, Leif; Evans, James E.; Bhattarai, Ashish; Hess, Wayne P.; El-Khoury, Patrick Z.

    2017-11-01

    We describe a unique approach to hyperspectral optical microscopy, herein achieved by coupling a hyperspectral imager to various optical microscopes. Hyperspectral fluorescence micrographs of isolated fluorescent beads are first employed to ensure spectral calibration of our detector and to gauge the attainable spatial resolution of our measurements. Different science applications of our instrument are then described. Spatially over-sampled absorption spectroscopy of a single lipid (18:1 Liss Rhod PE) layer reveals that optical densities on the order of 10-3 can be resolved by spatially averaging the recorded optical signatures. This is followed by three applications in the general areas of plasmonics and bioimaging. Notably, we deploy hyperspectral absorption microscopy to identify and image pigments within a simple biological system, namely, a single live Tisochrysis lutea cell. Overall, this work paves the way for multimodal spectral imaging measurements spanning the realms of several scientific disciplines.

  14. Optical Space Telescope Assembly

    Data.gov (United States)

    National Aeronautics and Space Administration — The Optical Space Telescope Assembly (OSTA) task is to demonstrate the technology readiness of assembling large space telescopes on orbit in 2015. This task is an...

  15. Optical design of PHARAO

    Science.gov (United States)

    Loesel, Jacques; Berthon, Jacques; Saccoccio, Muriel; Raimbault, Nathalie; Aubry, Yvan; Clairon, André; Laurent, Philippe; Lemonde, Pierre

    2017-11-01

    The purpose of the PHARAO project is to develop a new atomic clock generation in space. This clock takes advantage of the very low atomic velocities obtained by laser cooling techniques and the microgravity environment. Designing the PHARAO optical bench, which provides all the laser tools for the atomic manipulations, is a difficult task. In this paper we will give a global overview of the optical bench in term of functions, interfaces and performances. After establishing the optical parameters, which have an impact on the atomic clock performance, we present the model and software, which are used for the design and analysis of the optical system, taking into account the Gaussian laser beams. Some critical functions have been experimented and characterized to prove the model's accuracy.

  16. Electroabsorption optical modulator

    Energy Technology Data Exchange (ETDEWEB)

    Skogen, Erik J.

    2017-11-21

    An electroabsorption modulator incorporates waveguiding regions along the length of the modulator that include quantum wells where at least two of the regions have quantum wells with different bandgaps. In one embodiment of the invention, the regions are arranged such that the quantum wells have bandgaps with decreasing bandgap energy along the length of the modulator from the modulator's input to its output. The bandgap energy of the quantum wells may be decreased in discrete steps or continuously. Advantageously, such an arrangement better distributes the optical absorption as well as the carrier density along the length of the modulator. Further advantageously, the modulator may handle increased optical power as compared with prior art modulators of similar dimensions, which allows for improved link gain when the optical modulator is used in an analog optical communication link.

  17. Fiber Optics: No Illusion.

    Science.gov (United States)

    American School and University, 1983

    1983-01-01

    A campus computer center at Hofstra University (New York) that holds 70 terminals for student use was first a gymnasium, then a language laboratory. Strands of fiber optics are used for the necessary wiring. (MLF)

  18. Nonlinear Optical Terahertz Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — We develop a new approach to generation of THz radiation. Our method relies on mixing two optical frequency beams in a nonlinear crystalline Whispering Gallery Mode...

  19. Intracoronary optical coherence tomography

    DEFF Research Database (Denmark)

    Tenekecioglu, Erhan; Albuquerque, Felipe N; Sotomi, Yohei

    2017-01-01

    By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT)...

  20. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    la Cour, M; Kiilgaard, Jens Folke; Eysteinsson, T

    2000-01-01

    To investigate the influence of acute changes in intraocular pressure on the oxygen tension in the vicinity of the optic nerve head under control conditions and after intravenous administration of 500 mg of the carbonic anhydrase inhibitor dorzolamide....

  1. Optics of Nanofibers

    DEFF Research Database (Denmark)

    Bordo, Vladimir

    During the last decade, fabrication and investigation of submicron-sized optical fibers have been received growing attention. Such nanofibers or nanowires can be grown from both inorganic and organic semiconductor materials being arranged in mutually parallel nanoaggregates. Also, selected...

  2. Metrology for Freeform Optics

    Data.gov (United States)

    National Aeronautics and Space Administration — Science requirements for optical instrumentation are requiring larger fields of view and faster f-numbers to complete their objectives.   Additionally, opportunities...

  3. Tunable Optical Polymer Systems

    National Research Council Canada - National Science Library

    Jenekhe, S. A; Bard, Allen J; Chen, S. H; Hammond, P. T; Rothberg, L. J

    2004-01-01

    This multidisciplinary university research initiative (MURI) program investigated tunable optical polymer systems suitable for large-area color-switchable coatings and devices, displays, sensors, and other electronic applications...

  4. Fiber optic fluid detector

    Science.gov (United States)

    Angel, S. Michael

    1989-01-01

    Particular gases or liquids are detected with a fiber optic element (11, 11a to 11j) having a cladding or coating of a material (23, 23a to 23j) which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector (24, 24a to 24j) may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses.

  5. Magneto-Optic Field Coupling in Optical Fiber Bragg Gratings

    Science.gov (United States)

    Carman, Gregory P. (Inventor); Mohanchandra, Panduranga K. (Inventor); Emmons, Michael C. (Inventor); Richards, William Lance (Inventor)

    2016-01-01

    The invention is a magneto-optic coupled magnetic sensor that comprises a standard optical fiber Bragg grating system. The system includes an optical fiber with at least one Bragg grating therein. The optical fiber has at least an inner core and a cladding that surrounds the inner core. The optical fiber is part of an optical system that includes an interrogation device that provides a light wave through the optical fiber and a system to determine the change in the index of refraction of the optical fiber. The cladding of the optical fiber comprises at least a portion of which is made up of ferromagnetic particles so that the ferromagnetic particles are subject to the light wave provided by the interrogation system. When a magnetic field is present, the ferromagnetic particles change the optical properties of the sensor directly.

  6. Roadmap on optical security

    Science.gov (United States)

    Javidi, Bahram; Carnicer, Artur; Yamaguchi, Masahiro; Nomura, Takanori; Pérez-Cabré, Elisabet; Millán, María S.; Nishchal, Naveen K.; Torroba, Roberto; Fredy Barrera, John; He, Wenqi; Peng, Xiang; Stern, Adrian; Rivenson, Yair; Alfalou, A.; Brosseau, C.; Guo, Changliang; Sheridan, John T.; Situ, Guohai; Naruse, Makoto; Matsumoto, Tsutomu; Juvells, Ignasi; Tajahuerce, Enrique; Lancis, Jesús; Chen, Wen; Chen, Xudong; Pinkse, Pepijn W. H.; Mosk, Allard P.; Markman, Adam

    2016-08-01

    Information security and authentication are important challenges facing society. Recent attacks by hackers on the databases of large commercial and financial companies have demonstrated that more research and development of advanced approaches are necessary to deny unauthorized access to critical data. Free space optical technology has been investigated by many researchers in information security, encryption, and authentication. The main motivation for using optics and photonics for information security is that optical waveforms possess many complex degrees of freedom such as amplitude, phase, polarization, large bandwidth, nonlinear transformations, quantum properties of photons, and multiplexing that can be combined in many ways to make information encryption more secure and more difficult to attack. This roadmap article presents an overview of the potential, recent advances, and challenges of optical security and encryption using free space optics. The roadmap on optical security is comprised of six categories that together include 16 short sections written by authors who have made relevant contributions in this field. The first category of this roadmap describes novel encryption approaches, including secure optical sensing which summarizes double random phase encryption applications and flaws [Yamaguchi], the digital holographic encryption in free space optical technique which describes encryption using multidimensional digital holography [Nomura], simultaneous encryption of multiple signals [Pérez-Cabré], asymmetric methods based on information truncation [Nishchal], and dynamic encryption of video sequences [Torroba]. Asymmetric and one-way cryptosystems are analyzed by Peng. The second category is on compression for encryption. In their respective contributions, Alfalou and Stern propose similar goals involving compressed data and compressive sensing encryption. The very important area of cryptanalysis is the topic of the third category with two sections

  7. Optical Modeling and Polarization Calibration for CMB Measurements with Actpol and Advanced Actpol

    Science.gov (United States)

    Koopman, Brian; Austermann, Jason; Cho, Hsiao-Mei; Coughlin, Kevin P.; Duff, Shannon M.; Gallardo, Patricio A.; Hasselfield, Matthew; Henderson, Shawn W.; Ho, Shuay-Pwu Patty; Hubmayr, Johannes; hide

    2016-01-01

    The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive upgrade to the Atacama Cosmology Telescope, located at an elevation of 5190 m on Cerro Toco in Chile. ACTPol uses transition edge sensor bolometers coupled to orthomode transducers to measure both the temperature and polarization of the Cosmic Microwave Background (CMB). Calibration of the detector angles is a critical step in producing polarization maps of the CMB. Polarization angle offsets in the detector calibration can cause leakage in polarization from E to B modes and induce a spurious signal in the EB and TB cross correlations, which eliminates our ability to measure potential cosmological sources of EB and TB signals, such as cosmic birefringence. We calibrate the ACTPol detector angles by ray tracing the designed detector angle through the entire optical chain to determine the projection of each detector angle on the sky. The distribution of calibrated detector polarization angles are consistent with a global offset angle from zero when compared to the EB-nulling offset angle, the angle required to null the EB cross-correlation power spectrum. We present the optical modeling process. The detector angles can be cross checked through observations of known polarized sources, whether this be a galactic source or a laboratory reference standard. To cross check the ACTPol detector angles, we use a thin film polarization grid placed in front of the receiver of the telescope, between the receiver and the secondary reflector. Making use of a rapidly rotating half-wave plate (HWP) mount we spin the polarizing grid at a constant speed, polarizing and rotating the incoming atmospheric signal. The resulting sinusoidal signal is used to determine the detector angles. The optical modeling calibration was shown to be consistent with a global offset angle of zero when compared to EB nulling in the first ACTPol results and will continue to be a part of our calibration implementation. The first

  8. Optical remote sensing

    CERN Document Server

    Prasad, Saurabh; Chanussot, Jocelyn

    2011-01-01

    Optical remote sensing relies on exploiting multispectral and hyper spectral imagery possessing high spatial and spectral resolutions respectively. These modalities, although useful for most remote sensing tasks, often present challenges that must be addressed for their effective exploitation. This book presents current state-of-the-art algorithms that address the following key challenges encountered in representation and analysis of such optical remotely sensed data: challenges in pre-processing images, storing and representing high dimensional data, fusing different sensor modalities, patter

  9. Fiber optics welder

    Science.gov (United States)

    Higgins, R.W.; Robichaud, R.E.

    A system is described for welding fiber optic waveguides together. The ends of the two fibers to be joined together are accurately, collinearly aligned in a vertical orientation and subjected to a controlled, diffuse arc to effect welding and thermal conditioning. A front-surfaced mirror mounted at a 45/sup 0/ angle to the optical axis of a stereomicroscope mounted for viewing the junction of the ends provides two orthogonal views of the interface during the alignment operation.

  10. Surface optical vortices

    OpenAIRE

    Lembessis, V. E.; Babiker, M.; Andrews, D L.

    2009-01-01

    It is shown how the total internal reflection of orbital-angular-momentum-endowed light can lead to the generation of evanescent light possessing rotational properties in which the intensity distribution is firmly localized in the vicinity of the surface. The characteristics of these surface optical vortices depend on the form of the incident light and on the dielectric mismatch of the two media. The interference of surface optical vortices is shown to give rise to interesting phenomena, incl...

  11. Fiber optic detector

    Energy Technology Data Exchange (ETDEWEB)

    Partin, J.K.; Ward, T.E.; Grey, A.E.

    1990-12-31

    This invention is comprised of a portable fiber optic detector that senses the presence of specific target chemicals by exchanging the target chemical for a fluorescently-tagged antigen that is bound to an antibody which is in turn attached to an optical fiber. Replacing the fluorescently-tagged antigen reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

  12. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    la Cour, M; Kiilgaard, Jens Folke; Eysteinsson, T

    2000-01-01

    To investigate the influence of acute changes in intraocular pressure on the oxygen tension in the vicinity of the optic nerve head under control conditions and after intravenous administration of 500 mg of the carbonic anhydrase inhibitor dorzolamide.......To investigate the influence of acute changes in intraocular pressure on the oxygen tension in the vicinity of the optic nerve head under control conditions and after intravenous administration of 500 mg of the carbonic anhydrase inhibitor dorzolamide....

  13. Regeneration of Optic Nerve

    Directory of Open Access Journals (Sweden)

    Kwok-Fai So

    2011-05-01

    Full Text Available The optic nerve is part of the central nervous system (CNS and has a structure similar to other CNS tracts. The axons that form the optic nerve originate in the ganglion cell layer of the retina and extend through the optic tract. As a tissue, the optic nerve has the same organization as the white matter of the brain in regard to its glia. There are three types of glial cells: Oligodendrocytes, astrocytes, and microglia. Little structural and functional regeneration of the CNS takes place spontaneously following injury in adult mammals. In contrast, the ability of the mammalian peripheral nervous system (PNS to regenerate axons after injury is well documented. A number of factors are involved in the lack of CNS regeneration, including: (i the response of neuronal cell bodies against the damage; (ii myelin-mediated inhibition by oligodendrocytes; (iii glial scarring, by astrocytes; (iv macrophage infiltration; and (v insufficient trophic factor support. The fundamental difference in the regenerative capacity between CNS and PNS neuronal cell bodies has been the subject of intensive research. In the CNS the target normally conveys a retrograde trophic signal to the cell body. CNS neurons die because of trophic deprivation. Damage to the optic nerve disconnects the neuronal cell body from its target-derived trophic peptides, leading to the death of retinal ganglion cells. Furthermore, the axontomized neurons become less responsive to the peptide trophic signals they do receive. On the other hand, adult PNS neurons are intrinsically responsive to neurotrophic factors and do not lose trophic responsiveness after axotomy. In this talk different strategies to promote optic-nerve regeneration in adult mammals are reviewed. Much work is still needed to resolve many issues. This is a very important area of neuroregeneration and neuroprotection, as currently there is no cure after traumatic optic nerve injury or retinal disease such as glaucoma, which

  14. Optical fibre microwire sensors

    OpenAIRE

    Brambilla, G.; Belal, Mohammad; Jung, Y.; Song, Z.; Xu, F.; Newson, T.P.; Richardson, D.J.

    2011-01-01

    This paper reviews sensing applications of optical fibre microwires and nanowires. In addition to the usual benefits of sensors based on optical fibres, these sensors are extremely compact and have fast response speeds. In this review sensors will be grouped in three categories according to their morphology: linear sensors, resonant sensors and tip sensors. While linear and resonant sensors mainly exploit the fraction of power propagating outside the microwire physical boundary, tip sensors t...

  15. Fish eye optics

    Czech Academy of Sciences Publication Activity Database

    Hudec, René; Michalová, S.

    2017-01-01

    Roč. 47, č. 2 (2017), s. 94-99 ISSN 1335-1842. [INTEGRAL/BART Workshop /14./. Karlovy Vary, 03.04.2017-07.04.2017] Grant - others:GA ČR(CZ) GA13-33324S Institutional support: RVO:67985815 Keywords : fish eye optics * lobster eye optics * X-ray monitoring Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 0.336, year: 2016

  16. Noise in Optical Amplifiers

    DEFF Research Database (Denmark)

    Jeppesen, Palle

    1997-01-01

    Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived.......Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived....

  17. Cognitive Dynamic Optical Networks

    DEFF Research Database (Denmark)

    de Miguel, Ignacio; Duran, Ramon J.; Lorenzo, Ruben M.

    2013-01-01

    Cognitive networks are a promising solution for the control of heterogeneous optical networks. We review their fundamentals as well as a number of applications developed in the framework of the EU FP7 CHRON project.......Cognitive networks are a promising solution for the control of heterogeneous optical networks. We review their fundamentals as well as a number of applications developed in the framework of the EU FP7 CHRON project....

  18. Physics of optical tweezers.

    Science.gov (United States)

    Nieminen, Timo A; Knöner, Gregor; Heckenberg, Norman R; Rubinsztein-Dunlop, Halina

    2007-01-01

    We outline the basic principles of optical tweezers as well as the fundamental theory underlying optical tweezers. The optical forces responsible for trapping result from the transfer of momentum from the trapping beam to the particle and are explained in terms of the momenta of incoming and reflected or refracted rays. We also consider the angular momentum flux of the beam in order to understand and explain optical torques. In order to provide a qualitative picture of the trapping, we treat the particle as a weak positive lens and the forces on the lens are shown. However, this representation does not provide quantitative results for the force. We, therefore, present results of applying exact electromagnetic theory to optical trapping. First, we consider a tightly focused laser beam. We give results for trapping of spherical particles and examine the limits of trappability in terms of type and size of the particles. We also study the effect of a particle on the beam. This exact solution reproduces the same qualitative effect as when treating the particle as a lens where changes in the convergence or divergence and in the direction of the trapping beam result in restoring forces acting on the particle. Finally, we review the fundamental theory of optical tweezers.

  19. Optical switching systems using nanostructures

    DEFF Research Database (Denmark)

    Stubkjær, Kristian

    2004-01-01

    High capacity multiservice optical networks require compact and efficient switches. The potential benefits of optical switch elements based on nanostructured material are reviewed considering various material systems.......High capacity multiservice optical networks require compact and efficient switches. The potential benefits of optical switch elements based on nanostructured material are reviewed considering various material systems....

  20. Fundamentals of nonlinear optical materials

    Indian Academy of Sciences (India)

    Nonlinear optics; nonlinear polarization; optical fiber communication; optical switch- ing. PACS Nos 42.65Tg; ... The importance of nonlinear optics is to understand the nonlinear behavior in the induced polarization and to ..... but much work in material development and characterization remains to be done. 16. Conclusion.