WorldWideScience

Sample records for polarization voltage turned

  1. Estimation Method for Turn-off Collector Voltage of IGBTs Using Emitter-auxiliary Inductor

    DEFF Research Database (Denmark)

    Luo, Haoze; Iannuzzo, Francesco; Blaabjerg, Frede

    2016-01-01

    This paper presents a method for estimating the instantaneous turn-off collector voltage of high-power IGBT modules. Because of the parasitic inductors in circuit, the fast turn-off collector current usually leads to a voltage overshoot on IGBT modules during the turn-off transition. In terms...... of high-voltage and high-power IGBT module, there exists an emitter-auxiliary inductor between the power emitter and Kelvin emitter. The same variable dic/dt during turn-off transition will also induce a measurable voltage veE across the emitter-auxiliary inductor LeE. As a result, the hazardous turn......-off peak collector voltage can be reflected by the induced νeE in the case of fixed commutation loop inductors and emitter auxiliary inductor. Finally, a double pulse test platform is used to validate the effectiveness of estimation method. The estimation curves of turn-off collector voltage...

  2. Beam polarization during a Siberian snake turn-on

    International Nuclear Information System (INIS)

    Anferov, Vladimir A.

    1999-01-01

    Installing Siberian snakes in a circular proton accelerator allows one to overcome all spin depolarizing resonances even at very high energies. However, Siberian snake application at low energies is technically rather difficult. Turning snake on at some energy during acceleration would allow using Siberian snakes even in rings with low injection energies. It is shown that the beam polarization would be preserved during the snake ramp, provided that the snake is turned on in more than ten turns, and the energy is set near a half-integer Gγ

  3. Comparison between voltage by turn measured on different tokamaks operating in hybrid wave current drive regime

    International Nuclear Information System (INIS)

    Briffod, G.; Hoang, G.T.

    1987-06-01

    On a tokamak in a current drive operation with a hybrid wave, the R.F. current is estimated from the voltage drop by plasma turn generated by R.F. power application. This estimated current is not proportional to the injected power. There still exists in the plasma an electric field corresponding to the current part produced by induction. The role evaluation of this parameter on the current drive efficiency is important. In this report the relation voltage-R.F. current is studied on Petula and results on the voltage evolution by turn on different machines are compared [fr

  4. High voltage processing of the SLC polarized electron gun

    International Nuclear Information System (INIS)

    Saez, P.; Clendenin, J.; Garden, C.; Hoyt, E.; Klaisner, L.; Prescott, C.; Schultz, D.; Tang, H.

    1993-04-01

    The SLC polarized electron gun operates at 120 kV with very low dark current to maintain the ultra high vacuum (UHV). This strict requirement protects the extremely sensitive photocathode from contaminants caused by high voltage (HV) activity. Thorough HV processing is thus required x-ray sensitive photographic film, a nanoammeter in series with gun power supply, a radiation meter, a sensitive residual gas analyzer and surface x-ray spectrometry were used to study areas in the gun where HV activity occurred. By reducing the electric field gradients, carefully preparing the HV surfaces and adhering to very strict clean assembly procedures, we found it possible to process the gun so as to reduce both the dark current at operating voltage and the probability of HV discharge. These HV preparation and processing techniques are described

  5. Organic Field Effect Transistors with Dipole-Polarized Polymer Gate Dielectrics for Control of Threshold Voltage

    OpenAIRE

    Sakai, Heisuke; Takahashi, Yoshikazu; Murata, Hideyuki

    2007-01-01

    The authors demonstrate organic field effect transistors (OFETs) with a dipole-polarized polyurea for the gate dielectrics. In the dielectrics, the internal electric field induces the mobile charge carrier in the semiconductor layer to the semiconductor-dielectric interface. OFETs with dipole-polarized gate dielectrics exhibit lower threshold voltage. With nonpolarized gate dielectrics, the threshold voltage was -11.4 V, whereas that decreased to -5.3 V with polarized gate dielectrics. In a...

  6. A simple method of extracting the polarization charge density in the AlGaN/GaN heterostructure from current-voltage and capacitance-voltage characteristics

    International Nuclear Information System (INIS)

    Lü Yuan-Jie; Lin Zhao-Jun; Yu Ying-Xia; Meng Ling-Guo; Cao Zhi-Fang; Luan Chong-Biao; Wang Zhan-Guo

    2012-01-01

    An Ni Schottky contact on the AlGaN/GaN heterostructure is fabricated. The flat-band voltage for the Schottky contact on the AlGaN/GaN heterostructure is obtained from the forward current—voltage characteristics. With the measured capacitance—voltage curve and the flat-band voltage, the polarization charge density in the AlGaN/GaN heterostructure is investigated, and a simple formula for calculating the polarization charge density is obtained and analyzed. With the approach described in this paper, the obtained polarization charge density agrees well with the one calculated by self-consistently solving Schrodinger's and Poisson's equations

  7. Modeling charge polarization voltage for large lithium-ion batteries in electric vehicles

    Directory of Open Access Journals (Sweden)

    Yan Jiang

    2013-06-01

    Full Text Available Purpose: Polarization voltage of the lithium-ion battery is an important parameter that has direct influence on battery performance. The paper aims to analyze the impedance characteristics of the lithium-ion battery based on EIS data. Design/methodology/approach: The effects of currents, initial SOC of the battery on charge polarization voltage are investigated, which is approximately linear function of charge current. The change of charge polarization voltage is also analyzed with the gradient analytical method in the SOC domain. The charge polarization model with two RC networks is presented, and parts of model parameters like Ohmic resistance and charge transfer impedance are estimated by both EIS method and battery constant current testing method. Findings: This paper reveals that the Ohmic resistance accounts for much contribution to battery total polarization compared to charge transfer impedance. Practical implications: Experimental results demonstrate the efficacy of the model with the proposed identification method, which provides the foundation for battery charging optimization. Originality/value: The paper analyzed the impedance characteristics of the lithium-ion battery based on EIS data, presented a charge polarization model with two RC networks, and estimated parameters like Ohmic resistance and charge transfer impedance.

  8. Improved PHIP polarization using a precision, low noise, voltage controlled current source.

    Science.gov (United States)

    Agraz, Jose; Grunfeld, Alexander; Cunningham, Karl; Li, Debiao; Wagner, Shawn

    2013-10-01

    Existing para-hydrogen induced polarization (PHIP) instrumentation relies on magnetic fields to hyperpolarize substances. These hyperpolarized substances have enhanced magnetic resonance imaging (MRI) signals over 10,000 fold, allowing for MRI at the molecular level. Required magnetic fields are generated by energizing a solenoid coil with current produced by a voltage controlled voltage source (VCVS), also known as a power supply. A VCVS lacks the current regulation necessary to keep magnetic field fluctuations to a minimum, which results in low PHIP polarization. A voltage controlled current source (VCCS) is an electric circuit that generates a steady flow of electrons proportional to an input voltage. A low noise VCCS provides the solenoid current flow regulation necessary to generate a stable static magnetic field (Bo). We discuss the design and implementation of a low noise, high stability, VCCS for magnetic field generation with minimum variations. We show that a precision, low noise, voltage reference driving a metal oxide semiconductor field effect transistor (MOSFET) based current sink, results in the current flow control necessary for generating a low noise and high stability Bo. In addition, this work: (1) compares current stability for ideal VCVS and VCCS models using transfer functions (TF), (2) develops our VCCS design's TF, (3) measures our VCCS design's thermal & 1/f noise, and (4) measures and compares hydroxyethyl-propionate (HEP) polarization obtained using a VCVS and our VCCS. The hyperpolarization of HEP was done using a PHIP instrument developed in our lab. Using our VCCS design, HEP polarization magnitude data show a statistically significant increase in polarization over using a VCVS. Circuit schematic, bill of materials, board layout, TF derivation, and Matlab simulations code are included as supplemental files. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Differences between signal currents for both polarities of applied voltages on cavity ionization chambers

    International Nuclear Information System (INIS)

    Takata, N.

    2000-01-01

    It is necessary to obtain precise values of signal currents for the measurement of exposure rates for gamma rays with cavity ionization chambers. Signal currents are usually expected to have the same absolute values for both polarities of applied voltages. In the case of cylindrical cavity ionization chambers, volume recombination loss of ion pairs depends on the polarity of the applied voltage. This is because the values of mobility are different for positive and negative ions. It was found, however, that values of signal currents from a cylindrical ionization chamber change slightly more with a negative than with a positive applied voltage, even after being corrected for volume recombination loss. Moreover, absolute values of saturation currents, which are obtained by extrapolation of correction of initial recombination and diffusion loss, were larger for the negative than for the positive applied voltage. It is known from an experiment with parallel plate ionization chambers that when negative voltage is applied to the repeller electrode, the saturated signal current decreases with an increase in the applied voltage. This is because secondary electrons are accelerated and the stopping power of air for these electrons decreases. When positive voltage is applied, the reverse is true. The effects of acceleration and deceleration of secondary electrons by the electric field thus seem to cause a tendency opposite to the experimental results on the signal currents from cylindrical ionization chambers. The experimental results for the cylindrical ionization chamber can be explained as follows. When negative voltage is applied, secondary electrons are attracted to the central (collecting) electrode. Consequently, the path length of the trajectories of these secondary electrons in the ionization volume increases and signal current increases. The energy gain from the electric field by secondary electrons which stop in the ionization chamber also contributes to the

  10. Low turn-on voltage perovskite light-emitting diodes with methanol treated PEDOT:PSS as hole transport layer

    Science.gov (United States)

    Wang, Zijun; Li, Zhirun; Zhou, Dianli; Yu, Junsheng

    2017-12-01

    We demonstrate the reduced low turn-on voltage of perovskite light-emitting diodes (PeLEDs) with methanol (MeOH) treated poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) as a hole transport layer (HTL). The MeOH treated PEDOT:PSS layer presents improved hole injection through reducing the contact barrier between the HTL and the CH3NH3PbBr3 emitting layer without sacrificing the quality of the perovskite film, which was characterized by X-ray diffraction, scanning electron microscopy, and time-resolved photoluminescence analysis. The optimized PeLEDs with the MeOH treated PEDOT:PSS layer exhibit a low turn-on voltage of 2.4 V and a maximum luminance of 1565 cd/m2, which represents a significant improvement over the PeLEDs using a pristine PEDOT:PSS layer. The approach could be used as a general method for decreasing the hole-injection barrier of PeLEDs and, eventually, to enhance the device performance.

  11. Elimination of bus voltage impact on temperature sensitive electrical parameter during turn-on transition for junction temperature estimation of high-power IGBT modules

    DEFF Research Database (Denmark)

    Luo, Haoze; Iannuzzo, Francesco; Blaabjerg, Frede

    2017-01-01

    -sensitive electrical parameters (DTSEP) during turn-on transient is proposed. Two DTSEP, turn-on delay time (tdon) and the maximum increasing rate of collector current dic/dt(max), are combined to eliminate the bus voltage impact. Using the inherent emitter-auxiliary inductor LeE in high-power modules, the temperature......-dependent DTSEPs can be converted into a low-voltage and measurable signal. Finally, experiment results are exhibited to verify the effectiveness of proposed method....

  12. Voltage switching technique for detecting nuclear spin polarization in a quantum dot

    International Nuclear Information System (INIS)

    Takahashi, Ryo; Kono, Kimitoshi; Tarucha, Seigo; Ono, Keiji

    2010-01-01

    We have introduced a source-drain voltage switching technique for studying nuclear spins in a vertical double quantum dot. Switching the source-drain voltage between the spin-blockade state and the zero-bias Coulomb blockade state can tune the energy difference between the spin singlet and triplet, and effectively turn on/off the hyperfine interaction. Since the change in the nuclear spin state affects the source-drain current, nuclear spin properties can only be detected by transport measurement. Using this technique, we have succeeded in measuring the timescale of nuclear spin depolarization. Furthermore, combining this technique and an RF ac magnetic field, we successfully detected continuous-wave NMR signals of 75 As, 69 Ga, and 71 Ga, which are contained in a quantum dot. (author)

  13. The use of charge extraction by linearly increasing voltage in polar organic light-emitting diodes

    Science.gov (United States)

    Züfle, Simon; Altazin, Stéphane; Hofmann, Alexander; Jäger, Lars; Neukom, Martin T.; Schmidt, Tobias D.; Brütting, Wolfgang; Ruhstaller, Beat

    2017-05-01

    We demonstrate the application of the CELIV (charge carrier extraction by linearly increasing voltage) technique to bilayer organic light-emitting devices (OLEDs) in order to selectively determine the hole mobility in N,N0-bis(1-naphthyl)-N,N0-diphenyl-1,10-biphenyl-4,40-diamine (α-NPD). In the CELIV technique, mobile charges in the active layer are extracted by applying a negative voltage ramp, leading to a peak superimposed to the measured displacement current whose temporal position is related to the charge carrier mobility. In fully operating devices, however, bipolar carrier transport and recombination complicate the analysis of CELIV transients as well as the assignment of the extracted mobility value to one charge carrier species. This has motivated a new approach of fabricating dedicated metal-insulator-semiconductor (MIS) devices, where the extraction current contains signatures of only one charge carrier type. In this work, we show that the MIS-CELIV concept can be employed in bilayer polar OLEDs as well, which are easy to fabricate using most common electron transport layers (ETLs), like Tris-(8-hydroxyquinoline)aluminum (Alq3). Due to the macroscopic polarization of the ETL, holes are already injected into the hole transport layer below the built-in voltage and accumulate at the internal interface with the ETL. This way, by a standard CELIV experiment only holes will be extracted, allowing us to determine their mobility. The approach can be established as a powerful way of selectively measuring charge mobilities in new materials in a standard device configuration.

  14. Compensation of negative sequence stator flux of doubly-fed induction generator using polar voltage control-based direct torque control under unbalanced grid voltage condition

    Directory of Open Access Journals (Sweden)

    Badrinarayan Bansilal Pimple

    2015-02-01

    Full Text Available This study proposes a polar voltage control-based direct torque control method to reduce the effects of unbalanced grid voltage on doubly-fed induction generator (DFIG-based wind turbine system. Under unbalanced grid voltage, the stator flux has a negative sequence component which leads to second harmonic pulsation in torque, stator active power, stator reactive power, stator current and rotor current. In the control scheme, the negative sequence rotor voltage vector is controlled to compensate the negative sequence stator flux by negative sequence rotor flux. Simulation study is carried out on a 2 MW DFIG system using MATLAB/SIMULINK. Feasibility of the proposed control strategy is experimentally verified on a 1.5 kW DFIG system.

  15. Fast turn-off of high voltage 4H–SiC npn BJTs from the saturation on-state regime

    International Nuclear Information System (INIS)

    Ivanov, P A; Levinshtein, M E; Palmour, J W; Agarwal, A K; Zhang, J

    2010-01-01

    Fast turn-off of high-voltage (breakdown voltage ≥ 3 kV) 4H–SiC npn bipolar junction transistors driven in a deeply saturated regime has been reported. In the conventional turn-off mode (base current break), the turn-off delay and current fall times are 80 ns and 100 ns, respectively. It is shown that these times can be made as short as 20 and 4 ns, respectively, if a reverse base current pulse of appropriate amplitude is applied to sweep out minority carriers from the base. The experimental values of delay and turn-off times well coincide with those calculated in terms of the charge control model

  16. Determination of polarization fields in group III-nitride heterostructures by capacitance-voltage-measurements

    Energy Technology Data Exchange (ETDEWEB)

    Rychetsky, Monir, E-mail: monir.rychetsky@physik.tu-berlin.de; Avinc, Baran; Wernicke, Tim; Bellmann, Konrad; Sulmoni, Luca [Institute of Solid State Physics, Technische Universität Berlin, Berlin (Germany); Koslow, Ingrid; Rass, Jens; Kneissl, Michael [Institute of Solid State Physics, Technische Universität Berlin, Berlin (Germany); Ferdinand-Braun-Institut, Leibniz-Institut für Höchstfrequenztechnik, Berlin (Germany); Hoffmann, Veit; Weyers, Markus [Ferdinand-Braun-Institut, Leibniz-Institut für Höchstfrequenztechnik, Berlin (Germany); Wild, Johannes; Zweck, Josef [Fakultät für Physik, University of Regensburg, Regensburg (Germany); Witzigmann, Bernd [Computational Electronics and Photonics Group and CINSaT, University of Kassel, Kassel (Germany)

    2016-03-07

    The polarization fields in wurtzite group III-nitrides strongly influence the optical properties of InAlGaN-based light emitters, e.g., the electron and hole wave function overlap in quantum wells. In this paper, we propose a new approach to determine these fields by capacitance-voltage measurements (CVM). Sheet charges generated by a change of the microscopic polarization at heterointerfaces influence the charge distribution in PIN junctions and therefore the depletion width and the capacitance. We show that it is possible to determine the strength and direction of the internal fields by comparing the depletion widths of two PIN junctions, one influenced by internal polarization fields and one without as a reference. For comparison, we conducted coupled Poisson/carrier transport simulations on the CVM of the polarization-influenced sample. We also demonstrate the feasibility and limits of the method by determining the fields in GaN/InGaN and GaN/AlGaN double heterostructures on (0001) c-plane grown by metal organic vapor phase epitaxy and compare both evaluation methods. The method yields (−0.50 ± 0.07) MV/cm for In{sub 0.08}Ga{sub 0.92}N/GaN, (0.90 ± 0.13) MV/cm for Al{sub 0.18}Ga{sub 0.82}N/GaN, and (2.0 ± 0.3) MV/cm for Al{sub 0.31}Ga{sub 0.69}N/GaN heterostructures.

  17. Simulative and experimental investigation on stator winding turn and unbalanced supply voltage fault diagnosis in induction motors using Artificial Neural Networks.

    Science.gov (United States)

    Lashkari, Negin; Poshtan, Javad; Azgomi, Hamid Fekri

    2015-11-01

    The three-phase shift between line current and phase voltage of induction motors can be used as an efficient fault indicator to detect and locate inter-turn stator short-circuit (ITSC) fault. However, unbalanced supply voltage is one of the contributing factors that inevitably affect stator currents and therefore the three-phase shift. Thus, it is necessary to propose a method that is able to identify whether the unbalance of three currents is caused by ITSC or supply voltage fault. This paper presents a feedforward multilayer-perceptron Neural Network (NN) trained by back propagation, based on monitoring negative sequence voltage and the three-phase shift. The data which are required for training and test NN are generated using simulated model of stator. The experimental results are presented to verify the superior accuracy of the proposed method. Copyright © 2015. Published by Elsevier Ltd.

  18. High voltage, fast turn-on and turn-off switch: Final report for period September 2, 1998 - March 17, 1999

    International Nuclear Information System (INIS)

    Jochen Schein; Xiaoxi Xu; Niansheng Qi; Steven Gensler; Rahul Prasad; Mahadevan Krishnan

    1999-01-01

    The aspect to be investigated during this contract was an electron-beam triggered diamond switch to be used in high power modulators. Today's high power modulators require higher voltage switches than those developed to date. Specifically, the proposed 1 TeV linear collider, the NLC/ILC at the Stanford Linear Accelerator Center (SLAC), consists of two linacs with 6600 X-Band klystrons powered by 3300 high power modulators. These modulators require switches capable of handling 80 kV, switching 8 kA with pulse durations ranging from 2 ps (linac) to 6 micros (pre-linac) with switching times <50 ns at pulse repetition frequencies up to 180 Hz. In addition the large number of switches and other components dictate a pulse to pulse jitter of <10 ns and a mean time between failures of at least 50,000 hours. The present approach is to use hydrogen filled thyratrons. While these switches meet the voltage and conduction current requirements they lack the required reliability (pulse to pulse jitter) and lifetime. Research to improve these aspects is in progress. A solid state switch inherently offers the required reliability and lifetime. However, Si-based switches developed to date are limited to about 5 kV and several must be stacked in series to deliver the required voltage. This further increases the already large parts count and compromises reliability and lifetime. A monolithic, solid state switch capable of meeting all the requirements for X-Band modulators would be ideal. DOE selected this proposal for a Phase 1 SBIR award and this final report describes the progress made during the contract

  19. High voltage, fast turn-on and turn-off switch: Final report for period September 2, 1998 - March 17, 1999

    Energy Technology Data Exchange (ETDEWEB)

    Jochen Schein; Xiaoxi Xu; Niansheng Qi; Steven Gensler; Rahul Prasad; Mahadevan Krishnan

    1999-04-10

    The aspect to be investigated during this contract was an electron-beam triggered diamond switch to be used in high power modulators. Today's high power modulators require higher voltage switches than those developed to date. Specifically, the proposed 1 TeV linear collider, the NLC/ILC at the Stanford Linear Accelerator Center (SLAC), consists of two linacs with 6600 X-Band klystrons powered by 3300 high power modulators. These modulators require switches capable of handling 80 kV, switching 8 kA with pulse durations ranging from 2 ps (linac) to 6 {micro}s (pre-linac) with switching times <50 ns at pulse repetition frequencies up to 180 Hz. In addition the large number of switches and other components dictate a pulse to pulse jitter of <10 ns and a mean time between failures of at least 50,000 hours. The present approach is to use hydrogen filled thyratrons. While these switches meet the voltage and conduction current requirements they lack the required reliability (pulse to pulse jitter) and lifetime. Research to improve these aspects is in progress. A solid state switch inherently offers the required reliability and lifetime. However, Si-based switches developed to date are limited to about 5 kV and several must be stacked in series to deliver the required voltage. This further increases the already large parts count and compromises reliability and lifetime. A monolithic, solid state switch capable of meeting all the requirements for X-Band modulators would be ideal. DOE selected this proposal for a Phase 1 SBIR award and this final report describes the progress made during the contract.

  20. Ultra-low turn-on voltage and on-resistance vertical GaN-on-GaN Schottky power diodes with high mobility double drift layers

    Science.gov (United States)

    Fu, Houqiang; Huang, Xuanqi; Chen, Hong; Lu, Zhijian; Baranowski, Izak; Zhao, Yuji

    2017-10-01

    This letter reports the implementation of double-drift-layer (DDL) design into GaN vertical Schottky barrier diodes (SBDs) grown on free-standing GaN substrates. This design balances the trade-off between desirable forward turn-on characteristics and high reverse breakdown capability, providing optimal overall device performances for power switching applications. With a well-controlled metalorganic chemical vapor deposition process, the doping concentration of the top drift layer was reduced, which served to suppress the peak electric field at the metal/GaN interface and increase the breakdown voltages of the SBDs. The bottom drift layer was moderately doped to achieve low on-resistance to reduce power losses. At forward bias, the devices exhibited a record low turn-on voltage of 0.59 V, an ultra-low on-resistance of 1.65 mΩ cm2, a near unity ideality factor of 1.04, a high on/off ratio of ˜1010, and a high electron mobility of 1045.2 cm2/(V s). Detailed comparisons with conventional single-drift-layer (SDL) GaN vertical SBDs indicated that DDL design did not degrade the forward characteristics of the SBDs. At reverse bias, breakdown voltages of the DDL GaN SBDs were considerably enhanced compared to those of the conventional SDL devices. These results showed that GaN vertical SBDs with DDL designs are promising candidates for high efficiency, high voltage, high frequency power switching applications.

  1. Selective electromembrane extraction at low voltages based on analyte polarity and charge

    DEFF Research Database (Denmark)

    Domínguez, Noelia Cabaleiro; Gjelstad, Astrid; Nadal, Andrea Molina

    2012-01-01

    Electromembrane extraction (EME) at low voltage (0-15V) of 29 different basic model drug substances was investigated. The drug substances with logP......Electromembrane extraction (EME) at low voltage (0-15V) of 29 different basic model drug substances was investigated. The drug substances with logP...

  2. Homogeneous double-layer amorphous Si-doped indium oxide thin-film transistors for control of turn-on voltage

    Energy Technology Data Exchange (ETDEWEB)

    Kizu, Takio, E-mail: KIZU.Takio@nims.go.jp, E-mail: TSUKAGOSHI.Kazuhito@nims.go.jp; Tsukagoshi, Kazuhito, E-mail: KIZU.Takio@nims.go.jp, E-mail: TSUKAGOSHI.Kazuhito@nims.go.jp [International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science (NIMS), Tsukuba, Ibaraki 305-0044 (Japan); Aikawa, Shinya [International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science (NIMS), Tsukuba, Ibaraki 305-0044 (Japan); Research Institute for Science and Technology, Kogakuin University, Hachioji, Tokyo 192-0015 (Japan); Nabatame, Toshihide [MANA Foundry and MANA Advanced Device Materials Group, National Institute for Materials Science (NIMS), Tsukuba, Ibaraki 305-0044 (Japan); Fujiwara, Akihiko [Department of Nanotechnology for Sustainable Energy, School of Science and Technology, Kwansei Gakuin University, 2-1 Gakuen, Sanda, Hyogo 669-1337 (Japan); Ito, Kazuhiro; Takahashi, Makoto [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan)

    2016-07-28

    We fabricated homogeneous double-layer amorphous Si-doped indium oxide (ISO) thin-film transistors (TFTs) with an insulating ISO cap layer on top of a semiconducting ISO bottom channel layer. The homogeneously stacked ISO TFT exhibited high mobility (19.6 cm{sup 2}/V s) and normally-off characteristics after annealing in air. It exhibited normally-off characteristics because the ISO insulator suppressed oxygen desorption, which suppressed the formation of oxygen vacancies (V{sub O}) in the semiconducting ISO. Furthermore, we investigated the recovery of the double-layer ISO TFT, after a large negative shift in turn-on voltage caused by hydrogen annealing, by treating it with annealing in ozone. The recovery in turn-on voltage indicates that the dense V{sub O} in the semiconducting ISO can be partially filled through the insulator ISO. Controlling molecule penetration in the homogeneous double layer is useful for adjusting the properties of TFTs in advanced oxide electronics.

  3. Ion diode performance on a positive polarity inductive voltage adder with layered magnetically insulated transmission line flow

    International Nuclear Information System (INIS)

    Hinshelwood, D. D.; Schumer, J. W.; Allen, R. J.; Commisso, R. J.; Jackson, S. L.; Murphy, D. P.; Phipps, D.; Swanekamp, S. B.; Weber, B. V.; Ottinger, P. F.; Apruzese, J. P.; Cooperstein, G.; Young, F. C.

    2011-01-01

    A pinch-reflex ion diode is fielded on the pulsed-power machine Mercury (R. J. Allen, et al., 15th IEEE Intl. Pulsed Power Conf., Monterey, CA, 2005, p. 339), which has an inductive voltage adder (IVA) architecture and a magnetically insulated transmission line (MITL). Mercury is operated in positive polarity resulting in layered MITL flow as emitted electrons are born at a different potential in each of the adder cavities. The usual method for estimating the voltage by measuring the bound current in the cathode and anode of the MITL is not accurate with layered flow, and the interaction of the MITL flow with a pinched-beam ion diode load has not been studied previously. Other methods for determining the diode voltage are applied, ion diode performance is experimentally characterized and evaluated, and circuit and particle-in-cell (PIC) simulations are performed. Results indicate that the ion diode couples efficiently to the machine operating at a diode voltage of about 3.5 MV and a total current of about 325 kA, with an ion current of about 70 kA of which about 60 kA is proton current. It is also found that the layered flow impedance of the MITL is about half the vacuum impedance.

  4. Effect of gate voltage polarity on the ionic liquid gating behavior of NdNiO3/NdGaO3 heterostructures

    Directory of Open Access Journals (Sweden)

    Yongqi Dong

    2017-05-01

    Full Text Available The effect of gate voltage polarity on the behavior of NdNiO3 epitaxial thin films during ionic liquid gating is studied using in situ synchrotron X-ray techniques. We show that while negative biases have no discernible effect on the structure or composition of the films, large positive gate voltages result in the injection of a large concentration of oxygen vacancies (∼3% and pronounced lattice expansion (0.17% in addition to a 1000-fold increase in sheet resistance at room temperature. Despite the creation of large defect densities, the heterostructures exhibit a largely reversible switching behavior when sufficient time is provided for the vacancies to migrate in and out of the thin film surface. The results confirm that electrostatic gating takes place at negative gate voltages for p-type complex oxides while positive voltages favor the electrochemical reduction of Ni3+. Switching between positive and negative gate voltages therefore involves a combination of electronic and ionic doping processes that may be utilized in future electrochemical transistors.

  5. Significance of the double-layer capacitor effect in polar rubbery dielectrics and exceptionally stable low-voltage high transconductance organic transistors

    Science.gov (United States)

    Wang, Chao; Lee, Wen-Ya; Kong, Desheng; Pfattner, Raphael; Schweicher, Guillaume; Nakajima, Reina; Lu, Chien; Mei, Jianguo; Lee, Tae Hoon; Wu, Hung-Chin; Lopez, Jeffery; Diao, Ying; Gu, Xiaodan; Himmelberger, Scott; Niu, Weijun; Matthews, James R.; He, Mingqian; Salleo, Alberto; Nishi, Yoshio; Bao, Zhenan

    2015-12-01

    Both high gain and transconductance at low operating voltages are essential for practical applications of organic field-effect transistors (OFETs). Here, we describe the significance of the double-layer capacitance effect in polar rubbery dielectrics, even when present in a very low ion concentration and conductivity. We observed that this effect can greatly enhance the OFET transconductance when driven at low voltages. Specifically, when the polar elastomer poly(vinylidene fluoride-co-hexafluoropropylene) (e-PVDF-HFP) was used as the dielectric layer, despite a thickness of several micrometers, we obtained a transconductance per channel width 30 times higher than that measured for the same organic semiconductors fabricated on a semicrystalline PVDF-HFP with a similar thickness. After a series of detailed experimental investigations, we attribute the above observation to the double-layer capacitance effect, even though the ionic conductivity is as low as 10-10 S/cm. Different from previously reported OFETs with double-layer capacitance effects, our devices showed unprecedented high bias-stress stability in air and even in water.

  6. Differential voltage amplification from ferroelectric negative capacitance

    Science.gov (United States)

    Khan, Asif I.; Hoffmann, Michael; Chatterjee, Korok; Lu, Zhongyuan; Xu, Ruijuan; Serrao, Claudy; Smith, Samuel; Martin, Lane W.; Hu, Chenming; Ramesh, Ramamoorthy; Salahuddin, Sayeef

    2017-12-01

    We demonstrate that a ferroelectric can cause a differential voltage amplification without needing an external energy source. As the ferroelectric switches from one polarization state to the other, a transfer of energy takes place from the ferroelectric to the dielectric, determined by the ratio of their capacitances, which, in turn, leads to the differential amplification. This amplification is very different in nature from conventional inductor-capacitor based circuits where an oscillatory amplification can be observed. The demonstration of differential voltage amplification from completely passive capacitor elements only has fundamental ramifications for next generation electronics.

  7. Voltage reapplication rate control for commutation of thyristors

    Science.gov (United States)

    Rippel, Wally E. (Inventor); Edwards, Dean B. (Inventor)

    1982-01-01

    A circuit for commutating a thyristor (21) by shunting its current for a minimum interval, thereby removing sustaining voltage to said thyristor, then subsequently restoring voltage to said thyristor at a predetermined rate, utilizes a series combination of a commutation electronic switch (22) and an isolated dc voltage supply (23) connected in parallel with the thyristor. The voltage supply is arranged with a polarity that permits the current flowing through the thyristor in one direction to be bypassed through the series combination while the commutation switch is turned on and to reverse bias the thyristor when the commutation switch is fully on. A dv/dt control circuit (24) limits the rate of rise of voltage across the commutation switch (22) as it is turned off in response to a command input signal. The dv/dt control circuit is comprised of a constant current drive (31) and a capacitor (32) connected between the output terminal of the commutation switch and the control input terminal of the commutation switch. The thyristor may be a triac (40) with two commutation switches (42, 43), one for current of each polarity, or with a single commutation switch (55) and a bridge circuit (52-55) for selecting the polarity of the switch (56).

  8. Turned on/turned off

    DEFF Research Database (Denmark)

    Petersen, Eva Bendix

    2016-01-01

    position, it attempts to sense into the lived experience of being subject to, and of, turns in social theory. As a whole the paper seeks to work with and allow for multiplicity in tone, focus, researcher positioning, reader positioning, and more, to see what knowledge that does not seek confident closure...

  9. Tight Turns

    Directory of Open Access Journals (Sweden)

    Jenifer Sutherland

    2013-01-01

    Full Text Available The plain text was task-oriented in a roundabout way, providing detailed instructions for how NOT to build an elaborate sequence of bridges, each one bound to produce, according to chapters one through twenty-three, disastrous results. Graphic novels disguised as illuminated letters twisted the tent-dwelling decipherer into painful self-recognition. The flashlight followed the phases of the moon. Meanwhile one strand of marginalia, written in anxious back-slant, pleaded for some kind of adjustable form for managing the confluence, especially during flood season. I like what we came up with. 'We' is a little big word. In fact the tent turns out to be one of those Borgesian core-tech structures allowing for astonishing internal expansion. There's not much we didn't get in there and not much in there that didn't get us. So I suppose that's it. This tent. This confluence. These children who found me here, turned text into life and made life home.

  10. Turning collectors for solar radiation

    Science.gov (United States)

    Barak, Amitzur Z.

    1976-01-01

    A device is provided for turning a solar collector about the polar axis so that the collector is directed toward the sun as the sun tracks the sky each day. It includes two heat-expansive elements and a shadow plate. In the morning a first expansive element is heated, expands to turn the collector to face the sun, while the second expansive element is shaded by the plate. In the afternoon the second element is heated, expands to turn the collector to face the sun, while the first is shaded by the plate.

  11. High voltage power supply

    Science.gov (United States)

    Ruitberg, A. P.; Young, K. M. (Inventor)

    1985-01-01

    A high voltage power supply is formed by three discrete circuits energized by a battery to provide a plurality of concurrent output signals floating at a high output voltage on the order of several tens of kilovolts. In the first two circuits, the regulator stages are pulse width modulated and include adjustable ressistances for varying the duty cycles of pulse trains provided to corresponding oscillator stages while the third regulator stage includes an adjustable resistance for varying the amplitude of a steady signal provided to a third oscillator stage. In the first circuit, the oscillator, formed by a constant current drive network and a tuned resonant network included a step up transformer, is coupled to a second step up transformer which, in turn, supplies an amplified sinusoidal signal to a parallel pair of complementary poled rectifying, voltage multiplier stages to generate the high output voltage.

  12. Pulse-voltage fast generator

    International Nuclear Information System (INIS)

    Valeev, R.I.; Nikiforov, M.G.; Kharchenko, A.F.

    1988-01-01

    The design is described and the test results of a four-channel pulse-voltage generator with maximum output voltage 200 kV are presented. The measurement results of generator triggering time depending on the value and polarity of the triggering voltage pulse for different triggering circuits are presented. The tests have shown stable triggering of all four channels of the generator in the range up to 40 % from selfbreakdown voltage. The generator triggering delay in the given range is <25 ns, asynchronism in channel triggering is <±1 ns

  13. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  14. Current-voltage characteristics in organic field-effect transistors. Effect of interface dipoles

    Science.gov (United States)

    Sworakowski, Juliusz

    2015-07-01

    The role of polar molecules present at dielectric/semiconductor interfaces of organic field-effect transistors (OFETs) has been assessed employing the electrostatic model put forward in a recently published paper (Sworakowski et al., 2014). The interface dipoles create dipolar traps in the surface region of the semiconductor, their depths decreasing with the distance from the interface. This feature results in appearance of mobility gradients in the direction perpendicular to the dielectric/semiconductor interface, manifesting themselves in modification of the shapes of current-voltage characteristics. The effect may account for differences in carrier mobilities determined from the same experimental data using methods scanning different ranges of channel thicknesses (e.g., transconductances vs. transfer characteristics), differences between turn-on voltages and threshold voltages, and gate voltage dependence of mobility.

  15. Silicon Carbide Emitter Turn-Off Thyristor

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2008-01-01

    Full Text Available A novel MOS-controlled SiC thyristor device, the SiC emitter turn-off thyristor (ETO is a promising technology for future high-voltage switching applications because it integrates the excellent current conduction capability of a SiC thyristor with a simple MOS-control interface. Through unity-gain turn-off, the SiC ETO also achieves excellent Safe Operation Area (SOA and faster switching speeds than silicon ETOs. The world's first 4.5-kV SiC ETO prototype shows a forward voltage drop of 4.26 V at 26.5 A/cm2 current density at room and elevated temperatures. Tested in an inductive circuit with a 2.5 kV DC link voltage and a 9.56-A load current, the SiC ETO shows a fast turn-off time of 1.63 microseconds and a low 9.88 mJ turn-off energy. The low switching loss indicates that the SiC ETO could operate at about 4 kHz if 100 W/cm2 conduction and the 100 W/cm2 turn-off losses can be removed by the thermal management system. This frequency capability is about 4 times higher than 4.5-kV-class silicon power devices. The preliminary demonstration shows that the SiC ETO is a promising candidate for high-frequency, high-voltage power conversion applications, and additional developments to optimize the device for higher voltage (>5 kV and higher frequency (10 kHz are needed.

  16. Displacement and emission currents from PLZT 8/65/35 and 4/95/5 excited by a negative voltage pulse at the rear electrode

    CERN Document Server

    Benedek, G; Handerek, J; Marchesini, S; De Martinis, C; Riege, H; Scurati, A

    1997-01-01

    It is shown that non-prepoled PLZT ceramics, both in ferroelectric and antiferroelectric phase, emit intense current bursts when a negative exciting voltage is applied to the rear surface of the cathode. The spontaneous polarization induced in the bulk by applying the field through the cathode disk, creates a sheet of negative charge on the diode boundary of the ferroelectric. This, in turn, induces such a high electric field at the diode dielectric surface that electrons are ejected out from the ceramic surface into the vacuum. The coherent behaviour of the displacement and emitted current shows clearly that the emission is due to a variation of spontaneous polarization. A second effect generated by the application of the high voltage pulse at the rear side is the formation of a surface plasma. Applying a positive voltage to the anode, electrons are readily transferred through the diode gap.

  17. Voltage Control of Magnetic Anisotropy

    Science.gov (United States)

    Hao, Guanhua; Cao, Shi; Noviasky, Nick; Ilie, Carolina; Sokolov, Andre; Yin, Yuewei; Xu, Xiaoshan; Dowben, Peter

    Pd/Co/Gd2O3/Si heterostructures were fabricated via pulsed laser deposition and e-beam evaporation. Hysteresis loops, obtained by longitudinal magneto-optical Kerr-effect (MOKE) measurements, indicates an initial in-plane magnetic anisotropy. Applying a perpendicular voltage on the sample, the differences between the polar and longitudinal MOKE and anomalous Hall effect data indicates there is a reversible change in magnetic anisotropy, from in-plane to out-of-plane, with applied voltage. Prior work by others suggests that the change in magnetic anisotropy is due to redox reactions at the Co/Gd2O3 interference. Voltage controlled magnetism can result from changing interfacial chemistry and does not always require a magneto-electric coupling tensor.

  18. A New Asymmetrical Current-fed Converter with Voltage Lifting

    Directory of Open Access Journals (Sweden)

    DELSHAD, M.

    2011-05-01

    Full Text Available This paper presents a new zero voltage switching current-fed DC-DC converter with high voltage gain. In this converter all switches (main and auxiliary turn on under zero voltage switching and turn off under almost zero voltage switching due to snubber capacitor. Furthermore, the voltage spike across the main switch due to leakage inductance of forward transformer is absorbed. The flyback transformer which is connected to the output in series causes to high voltage gain and less voltage stress on the power devices. Considering high efficiency and voltage gain of this converter, it is suitable for green generated systems such as fuel cells or photovoltaic systems. The presented experimental results verify the integrity of the proposed converter.

  19. The Local Turn

    NARCIS (Netherlands)

    Warren, Carol; Visser, Leontine

    2016-01-01

    The local turn in good governance theory and practice responded to critiques of the ineffectiveness of state management and the inequity of privatization alternatives in natural resource management. Confounding expectations of greater effectiveness from decentralised governance, including

  20. Turning Sunlight into Electricity

    Indian Academy of Sciences (India)

    module' or a 'solar panel' that provides a useful voltage and current. The efficiency of silicon solar cells for the conversion of light energy to electricity has increased steadily over the years to present values of up to 18% for amorphous silicon, and 25% for single crystal cells. At the same time, the cost of cells has fallen.

  1. Polarization Optics

    OpenAIRE

    Fressengeas, Nicolas

    2010-01-01

    The physics of polarization optics *Polarized light propagation *Partially polarized light; DEA; After a brief introduction to polarization optics, this lecture reviews the basic formalisms for dealing with it: Jones Calculus for totally polarized light and Stokes parameters associated to Mueller Calculus for partially polarized light.

  2. Turning Sunlight into Electricity

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 11; Issue 7. Turning Sunlight into Electricity - Inorganic Solar Cells and Beyond. A K Shukla. General Article Volume 11 Issue 7 July 2006 pp 42-50. Fulltext. Click here to view fulltext PDF. Permanent link:

  3. Turning lead into gold

    DEFF Research Database (Denmark)

    Jensen, Steffen Moltrup Ernø

    For years the field of entrepreneurship has been blinded by the alchemical promise of turning lead into gold, of finding the ones most likely to become the next Branson, Zuckerberg or Gates. The promise has been created in the midst of political and scientific agendas where certain individuals...

  4. Turning to alcohol?

    International Nuclear Information System (INIS)

    Reiboro, S.K.

    1998-01-01

    Brazil is examining whether turning to alcohol could solve its problems. The fuel alcohol producers are lobbying hard for the government to increase the use of alcohol to fuel the country's cars. Not only does using alcohol reduce CO 2 , runs the argument, but the Kyoto agreement might just attract international financing for the project. (author)

  5. Polarization-enhanced InGaN/GaN-based hybrid tunnel junction contacts to GaN p–n diodes and InGaN LEDs

    KAUST Repository

    Mughal, Asad J.

    2017-11-27

    Improved turn-on voltages and reduced series resistances were realized by depositing highly Si-doped n-type GaN using molecular beam epitaxy on polarization-enhanced p-type InGaN contact layers grown using metal–organic chemical vapor deposition. We compared the effects of different Si doping concentrations and the addition of p-type InGaN on the forward voltages of p–n diodes and light-emitting diodes, and found that increasing the Si concentrations from 1.9 × 1020 to 4.6 × 1020 cm−3 and including a highly doped p-type InGaN at the junction both contributed to reductions in the depletion width, the series resistance of 4.2 × 10−3–3.4 × 10−3 Ωcenterdotcm2, and the turn-on voltages of the diodes.

  6. The SLAC polarized electron source

    International Nuclear Information System (INIS)

    Tang, H.; Alley, R.; Frisch, J.

    1995-06-01

    The SLAC polarized electron source employs a photocathode DC high voltage gun with a loadlock and a YAG pumped Ti:sapphire laser system for colliding beam experiments or a flash lamp pumped Ti:sapphire laser for fixed target experiments. It uses a thin, strained GaAs(100) photocathode, and is capable of producing a pulsed beam with a polarization of ≥80% and a peak current exceeding 10 A. Its operating efficiency has reached 99%. The physics and technology of producing high polarization electron beams from a GaAs photocathode will be reviewed. The prospects of realizing a polarized electron source for future linear colliders will also be discussed

  7. DVR(Dynamic Voltage Restorer)

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. DVR(Dynamic Voltage Restorer). Supply voltage Sag compensation. Supply voltage Swell Compensation. Balancing the Load voltage. Compensation of Supply Voltage Harmonics.

  8. Hungary's U-Turn

    OpenAIRE

    Kornai, János

    2015-01-01

    For two decades Hungary, like the other Eastern European countries, followed a general policy of establishing and strengthening the institutions of democracy, rule of law, and a market economy based on private property. However, since the elections of 2010, when Viktor Orbán's Fidesz party came to power, Hungary has made a dramatic U-turn. This article investigates the different spheres of society: political institutions, the rule of law, and the influence of state and market on one another, ...

  9. Turning Desirements into Requirements

    Science.gov (United States)

    2015-09-01

    27 Defense AT&L: September–October 2015 Turning “Desirements” into Requirements Charles Court Court is the Requirements Center Director at the...Defense Systems Management College at the Defense Acquisition University at Fort Belvoir, Virginia. He is a former Wild Weasel Electronic Warfare Officer...a Mustang would do much better. (The author wanted the Aston Martin from the movie “Goldfinger.” You know: The one with the ejection seat, automated

  10. Diamond turning of glass

    Energy Technology Data Exchange (ETDEWEB)

    Blackley, W.S.; Scattergood, R.O.

    1988-12-01

    A new research initiative will be undertaken to investigate the critical cutting depth concepts for single point diamond turning of brittle, amorphous materials. Inorganic glasses and a brittle, thermoset polymer (organic glass) are the principal candidate materials. Interrupted cutting tests similar to those done in earlier research are Ge and Si crystals will be made to obtain critical depth values as a function of machining parameters. The results will provide systematic data with which to assess machining performance on glasses and amorphous materials

  11. Turning scar into muscle.

    Science.gov (United States)

    de Carvalho, Antonio Carlos Campos; Carvalho, Adriana Bastos

    2012-09-26

    After the demonstration that somatic cells could be reprogrammed to a pluripotent state, exciting new prospects were opened for the cardiac regeneration field. It did not take long for the development of strategies to convert somatic cells directly into cardiomyocytes. Despite the intrinsic difficulties of cell reprogramming, such as low efficiency, the therapeutic possibilities created by the ability to turn scar into muscle are enormous. Here, we discuss some of the major advances and strategies used in direct cardiac reprogramming and examine discrepancies and concerns that still need to be resolved in the field.

  12. Fermilab turns 50! Congratulations!

    CERN Multimedia

    Staff Association

    2017-01-01

    This year Fermilab turns 50 and the celebrations are ongoing. The ties between CERN and Fermilab are numerous and have been ranging from competition between two labs at the forefront of their field, e.g. with the chase of the top quark, finally discovered by Fermilab, to outright collaboration, e.g. on LHC low-beta quadrupole magnet development and production and in the CMS collaboration. In June, in the name of the CERN staff and scientific community, the CERN Staff Association sent a message to the Fermilab staff and scientific community, through Dr. Nigel Lockyer, Fermilab Director. The letter, and the assurance from Nigel Lockyer that the message has been passed onto the Fermilab community can be found on our website. Congratulations to Fermilab on its fiftieth Anniversary, and to the staff and collaborators who made this laboratory through their hard work, dedication and vision!

  13. The Affective Turn

    Directory of Open Access Journals (Sweden)

    Alí Lara

    2013-11-01

    Full Text Available In the last decade studies on affect and emotions have become relevant in the social sciences. This is not just a fad guideline, but instead a simultaneous reader of public life changes and subjective experience, from which it is also being transformed the knowledge production. Such a trend has been known as ‘The Affective Turn’ within the Anglophone Academy. Here we will translate it as ‘El Giro Afectivo’. This turn, so far, has not dabbled in the social science literature that is written in Spanish. This paper draws on a singular panorama of discussions about contemporary social studies of affect and emotion, and it’s vertebrate by some of its expressions in the contemporary academy.

  14. Turn Continuation and Clause Combinations

    Science.gov (United States)

    Couper-Kuhlen, Elizabeth

    2012-01-01

    This article explores the viability of the analytic distinction between "turn-constructional unit (TCU) continuation" (i.e., continuing a turn beyond a point of possible completion with grammatically dependent material) and "new TCU" (i.e., continuing a turn with grammatically independent material) when hypotactic clause combinations are involved.…

  15. Stray voltage mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Jamali, B.; Piercy, R.; Dick, P. [Kinetrics Inc., Toronto, ON (Canada). Transmission and Distribution Technologies

    2008-04-09

    This report discussed issues related to farm stray voltage and evaluated mitigation strategies and costs for limiting voltage to farms. A 3-phase, 3-wire system with no neutral ground was used throughout North America before the 1930s. Transformers were connected phase to phase without any electrical connection between the primary and secondary sides of the transformers. Distribution voltage levels were then increased and multi-grounded neutral wires were added. The earth now forms a parallel return path for the neutral current that allows part of the neutral current to flow continuously through the earth. The arrangement is responsible for causing stray voltage. Stray voltage causes uneven milk production, increased incidences of mastitis, and can create a reluctance to drink water amongst cows when stray voltages are present. Off-farm sources of stray voltage include phase unbalances, undersized neutral wire, and high resistance splices on the neutral wire. Mitigation strategies for reducing stray voltage include phase balancing; conversion from single to 3-phase; increasing distribution voltage levels, and changing pole configurations. 22 refs., 5 tabs., 13 figs.

  16. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  17. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  18. Polarization states encoded by phase modulation for high bit rate quantum key distribution

    International Nuclear Information System (INIS)

    Liu Xiaobao; Tang Zhilie; Liao Changjun; Lu Yiqun; Zhao Feng; Liu Songhao

    2006-01-01

    We present implementation of quantum cryptography with polarization code by wave-guide type phase modulator. At four different low input voltages of the phase modulator, coder encodes pulses into four different polarization states, 45 o , 135 o linearly polarized or right, left circle polarized, while the decoder serves as the complementary polarizers

  19. Polarized source upgrading

    International Nuclear Information System (INIS)

    Clegg, T.B.; Rummel, R.L.; Carter, E.P.; Westerfeldt, C.R.; Lovette, A.W.; Edwards, S.E.

    1985-01-01

    The decision was made this past year to move the Lamb-shift polarized ion source which was first installed in the laboratory in 1970. The motivation was the need to improve the flexibility of spin-axis orientation by installing the ion source with a new Wien-filter spin precessor which is capable of rotating physically about the beam axis. The move of the polarized source was accomplished in approximately two months, with the accelerator being turned off for experiments during approximately four weeks of this time. The occasion of the move provided the opportunity to rewire completely the entire polarized ion source frame and to rebuild approximately half of the electronic chassis on the source. The result is an ion source which is now logically wired and carefully documented. Beams obtained from the source are much more stable than those previously available

  20. PLZT light transmittance memory driven with an asymmetric voltage pulse

    International Nuclear Information System (INIS)

    Inoue, Kazuhiko; Morita, Takeshi

    2010-01-01

    PLZT is a ferroelectric electro-optic material, which has been operated with a constant voltage supply to keep a certain optical property. In this study, we propose an optical transmittance memory effect by controlling the domain conditions. The keypoint is to use an asymmetric voltage pulse. In the positive direction, a sufficiently-large voltage is applied to align the polarization directions. After this operation, a relatively small light transmittance is memorized even after removing the electric field. On the other hand, in the negative direction, the amplitude of the voltage is adjusted to the coercive electric field. In this condition, the domain structure is almost the same as the depolarization state. With this voltage supply, the maximum light transmittance can be kept after removing the electric field. Using these voltage operations, the PLZT can obtain two light transmittance states depending on the domain structure. This memory effect should be useful for innovative optical scanners or shutters in the future.

  1. Sandstone Turning by Abrasive Waterjet

    Czech Academy of Sciences Publication Activity Database

    Hlaváček, Petr; Cárach, J.; Hloch, Sergej; Vasilko, K.; Klichová, Dagmar; Klich, Jiří; Lehocká, D.

    2015-01-01

    Roč. 48, č. 6 (2015), s. 2489-2493 ISSN 0723-2632 R&D Projects: GA MŠk ED2.1.00/03.0082; GA MŠk(CZ) LO1406 Institutional support: RVO:68145535 Keywords : turning away from the jet * conventional turning towards the jet * sandstone * abrasive water jet Subject RIV: JQ - Machines ; Tools Impact factor: 2.386, year: 2015 http://www.springerprofessional.de/sandstone-turning-by-abrasive-waterjet/6038028.html

  2. Sandstone Turning by Abrasive Waterjet

    Czech Academy of Sciences Publication Activity Database

    Hlaváček, Petr; Cárach, J.; Hloch, Sergej; Vasilko, K.; Klichová, Dagmar; Klich, Jiří; Lehocká, D.

    2015-01-01

    Roč. 48, č. 6 (2015), s. 2489-2493 ISSN 0723-2632 R&D Projects: GA MŠk ED2.1.00/03.0082; GA MŠk(CZ) LO1406 Institutional support: RVO:68145535 Keywords : turning away from the jet * conventional turning towards the jet * sandstone * abrasive water jet Subject RIV: JQ - Machines ; Tools Impact factor: 2.386, year: 2015 http://www.springerprofessional.de/sandstone-turning-by-abrasive- water jet/6038028.html

  3. Simple Neutral-Point Voltage Control for Three-Level Inverters Using a Discontinuous Pulse Width Modulation

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, K.B.; Lee, Hyun-Hee

    2013-01-01

    This paper proposes a neutral-point voltage balancing method for a three-level inverter that uses discontinuous pulse width modulation (DPWM). The performance of a three-level inverter system is affected by the neutral-point voltage unbalancing. Therefore, the voltages of series connected dc......-link capacitors should be equal. Generally, the offset voltage is added to reference voltages in the conventional voltage balancing method. However, when using DPWM, the performance of conventional balancing method is limitary because turn-on and turn-off switching occurs at regular intervals. The proposed method...

  4. Polarization developments

    International Nuclear Information System (INIS)

    Prescott, C.Y.

    1993-07-01

    Recent developments in laser-driven photoemission sources of polarized electrons have made prospects for highly polarized electron beams in a future linear collider very promising. This talk discusses the experiences with the SLC polarized electron source, the recent progress with research into gallium arsenide and strained gallium arsenide as a photocathode material, and the suitability of these cathode materials for a future linear collider based on the parameters of the several linear collider designs that exist

  5. Tip-induced domain structures and polarization switching in ferroelectric amino acid glycine

    Energy Technology Data Exchange (ETDEWEB)

    Seyedhosseini, E., E-mail: Seyedhosseini@ua.pt; Ivanov, M. [CICECO-Aveiro Institute of Materials and Department of Physics, University of Aveiro, 3810-193 Aveiro (Portugal); Bdikin, I. [TEMA and Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro (Portugal); Vasileva, D. [Institute of Natural Sciences, Ural Federal University, 620000 Ekaterinburg (Russian Federation); Kudryavtsev, A. [Moscow State Institute of Radioengineering, Electronics and Automation, 119454 Moscow (Russian Federation); Rodriguez, B. J. [Conway Institute of Biomolecular and Biomedical Research and School of Physics, University College Dublin, Dublin (Ireland); Kholkin, A. L. [CICECO-Aveiro Institute of Materials and Department of Physics, University of Aveiro, 3810-193 Aveiro (Portugal); Institute of Natural Sciences, Ural Federal University, 620000 Ekaterinburg (Russian Federation)

    2015-08-21

    Bioorganic ferroelectrics and piezoelectrics are becoming increasingly important in view of their intrinsic compatibility with biological environment and biofunctionality combined with strong piezoelectric effect and a switchable polarization at room temperature. Here, we study tip-induced domain structures and polarization switching in the smallest amino acid β-glycine, representing a broad class of non-centrosymmetric amino acids. We show that β-glycine is indeed a room-temperature ferroelectric and polarization can be switched by applying a bias to non-polar cuts via a conducting tip of atomic force microscope (AFM). Dynamics of these in-plane domains is studied as a function of an applied voltage and pulse duration. The domain shape is dictated by polarization screening at the domain boundaries and mediated by growth defects. Thermodynamic theory is applied to explain the domain propagation induced by the AFM tip. Our findings suggest that the properties of β-glycine are controlled by the charged domain walls which in turn can be manipulated by an external bias.

  6. Turning patients over in bed

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000426.htm Turning patients over in bed To use the sharing features on this page, ... Patient The following steps should be followed when turning a patient: If you can, raise the bed to a level that reduces back strain for ...

  7. A soft switching with reduced voltage stress ZVT-PWM full-bridge converter

    Science.gov (United States)

    Sahin, Yakup; Ting, Naim Suleyman; Acar, Fatih

    2018-04-01

    This paper introduces a novel active snubber cell for soft switching pulse width modulation DC-DC converters. In the proposed converter, the main switch is turned on under zero voltage transition and turned off under zero voltage switching (ZVS). The auxiliary switch is turned on under zero current switching (ZCS) and turned off under zero current transition. The main diode is turned on under ZVS and turned off under ZCS. All of the other semiconductors in the converter are turned on and off with soft switching. There is no extra voltage stress on the semiconductor devices. Besides, the proposed converter has simple structure and ease of control due to common ground. The detailed theoretical analysis of the proposed converter is presented and also verified with both simulation and experimental study at 100 kHz switching frequency and 600 W output power. Furthermore, the efficiency of the proposed converter is 95.7% at nominal power.

  8. Time-division-multiplex control scheme for voltage multiplier rectifiers

    Directory of Open Access Journals (Sweden)

    Bin-Han Liu

    2017-03-01

    Full Text Available A voltage multiplier rectifier with a novel time-division-multiplexing (TDM control scheme for high step-up converters is proposed in this study. In the proposed TDM control scheme, two full-wave voltage doubler rectifiers can be combined to realise a voltage quadrupler rectifier. The proposed voltage quadrupler rectifier can reduce transformer turn ratio and transformer size for high step-up converters and also reduce voltage stress for the output capacitors and rectifier diodes. An N-times voltage rectifier can be straightforwardly produced by extending the concepts from the proposed TDM control scheme. A phase-shift full-bridge (PSFB converter is adopted in the primary side of the proposed voltage quadrupler rectifier to construct a PSFB quadrupler converter. Experimental results for the PSFB quadrupler converter demonstrate the performance of the proposed TDM control scheme for voltage quadrupler rectifiers. An 8-times voltage rectifier is simulated to determine the validity of extending the proposed TDM control scheme to realise an N-times voltage rectifier. Experimental and simulation results show that the proposed TDM control scheme has great potential to be used in high step-up converters.

  9. High voltage DC power supply

    Science.gov (United States)

    Droege, Thomas F.

    1989-01-01

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

  10. Mechanical writing of ferroelectric polarization.

    Science.gov (United States)

    Lu, H; Bark, C-W; Esque de los Ojos, D; Alcala, J; Eom, C B; Catalan, G; Gruverman, A

    2012-04-06

    Ferroelectric materials are characterized by a permanent electric dipole that can be reversed through the application of an external voltage, but a strong intrinsic coupling between polarization and deformation also causes all ferroelectrics to be piezoelectric, leading to applications in sensors and high-displacement actuators. A less explored property is flexoelectricity, the coupling between polarization and a strain gradient. We demonstrate that the stress gradient generated by the tip of an atomic force microscope can mechanically switch the polarization in the nanoscale volume of a ferroelectric film. Pure mechanical force can therefore be used as a dynamic tool for polarization control and may enable applications in which memory bits are written mechanically and read electrically.

  11. Mechanical Writing of Ferroelectric Polarization

    Science.gov (United States)

    Lu, H.; Bark, C.-W.; Esque de los Ojos, D.; Alcala, J.; Eom, C. B.; Catalan, G.; Gruverman, A.

    2012-04-01

    Ferroelectric materials are characterized by a permanent electric dipole that can be reversed through the application of an external voltage, but a strong intrinsic coupling between polarization and deformation also causes all ferroelectrics to be piezoelectric, leading to applications in sensors and high-displacement actuators. A less explored property is flexoelectricity, the coupling between polarization and a strain gradient. We demonstrate that the stress gradient generated by the tip of an atomic force microscope can mechanically switch the polarization in the nanoscale volume of a ferroelectric film. Pure mechanical force can therefore be used as a dynamic tool for polarization control and may enable applications in which memory bits are written mechanically and read electrically.

  12. A gate drive circuit for gate-turn-off (GTO) devices in series stack

    International Nuclear Information System (INIS)

    Despe, O.

    1999-01-01

    A gate-turn-off (GTO) switch is under development at the Advanced Photon Source as a replacement for a thyratron switch in high power pulsed application. The high voltage in the application requires multiple GTOs connected in series. One component that is critical to the success of GTO operation is the gate drive circuit. The gate drive circuit has to provide fast high-current pulses to the GTO gate for fast turn-on and turn-off. It also has to be able to operate while floating at high voltage. This paper describes a gate drive circuit that meets these requirements

  13. Polarization, political

    NARCIS (Netherlands)

    Wojcieszak, M.; Mazzoleni, G.; Barnhurst, K.G.; Ikeda, K.; Maia, R.C.M.; Wessler, H.

    2015-01-01

    Polarization has been studied in three different forms: on a social, group, and individual level. This entry first focuses on the undisputed phenomenon of elite polarization (i.e., increasing adherence of policy positions among the elites) and also outlines different approaches to assessing mass

  14. Polarization holography

    DEFF Research Database (Denmark)

    Nikolova, L.; Ramanujam, P.S.

    Current research into holography is concerned with applications in optically storing, retrieving, and processing information. Polarization holography has many unique properties compared to conventional holography. It gives results in high efficiency, achromaticity, and special polarization...... properties. This books reviews the research carried out in this field over the last 15 years. The authors provide basic concepts in polarization and the propagation of light through anisotropic materials, before presenting a sound theoretical basis for polarization holography. The fabrication...... and characterization of azobenzene based materials, which remain the most efficient for the purpose, is described in detail. This is followed by a description of other materials that are used in polarization holography. An in-depth description of various applications, including display holography and optical storage...

  15. Past lessons and future importance of polarization

    International Nuclear Information System (INIS)

    Lipkin, H.J.

    1980-01-01

    Polarization and spin effects have traditionally brought surprises to physicists particularly to those who thought that such effects were unimportant. In hadron physics, large unexplained effects keep turning up and are still unresolved puzzles. A good measurement of the uninteresting beta ray polarization could have discovered parity nonconservation many years before its prediction by Lee and Yang. Nobody knows whether there are further exciting discoveries of this kind waiting for polarization experiments

  16. All-fiber polarization switch

    Science.gov (United States)

    Knape, Harald; Margulis, Walter

    2007-03-01

    We report an all-fiber polarization switch made out of silica-based microstructured fiber suitable for Q-switching all-fiber lasers. Nanosecond high-voltage pulses are used to heat and expand an internal electrode to cause λ/2-polarization rotation in less than 10 ns for 1.5 μm light. The 10 cm long component has an experimentally measured optical insertion loss of 0.2 dB and a 0-10 kHz repetition frequency capacity and has been durability tested for more than 109 pulses.

  17. A dead-zone free ⁴He atomic magnetometer with intensity-modulated linearly polarized light and a liquid crystal polarization rotator.

    Science.gov (United States)

    Wu, T; Peng, X; Lin, Z; Guo, H

    2015-10-01

    We demonstrate an all-optical (4)He atomic magnetometer experimental scheme based on an original Bell-Bloom configuration. A single intensity-modulated linearly polarized laser beam is used both for generating spin polarization within a single (4)He vapor and probing the spin precessing under a static magnetic field. The transmitted light signal from the vapor is then phase-sensitively detected at the modulation frequency and its harmonics, which lead to the atomic magnetic resonance signals. Based on this structure, a liquid crystal is added in our magnetometer system and constitutes a polarization rotator. By controlling the voltage applied on the liquid crystal, the light linear polarization vector can be kept perpendicular with the ambient magnetic field direction, which in turn provides the maximum resonance signal amplitude. Moreover, the system exhibits a magnetic-field noise floor of about 2pT/√Hz, which is not degraded due to the presence of the liquid crystal and varying magnetic field direction. The experiment results prove that our method can eliminate the dead-zone effect, improve the system spatial isotropy, and thus be suitable in mobile applications.

  18. Models and Algorithms for Tracking Target with Coordinated Turn Motion

    Directory of Open Access Journals (Sweden)

    Xianghui Yuan

    2014-01-01

    Full Text Available Tracking target with coordinated turn (CT motion is highly dependent on the models and algorithms. First, the widely used models are compared in this paper—coordinated turn (CT model with known turn rate, augmented coordinated turn (ACT model with Cartesian velocity, ACT model with polar velocity, CT model using a kinematic constraint, and maneuver centered circular motion model. Then, in the single model tracking framework, the tracking algorithms for the last four models are compared and the suggestions on the choice of models for different practical target tracking problems are given. Finally, in the multiple models (MM framework, the algorithm based on expectation maximization (EM algorithm is derived, including both the batch form and the recursive form. Compared with the widely used interacting multiple model (IMM algorithm, the EM algorithm shows its effectiveness.

  19. Polar Bears

    Science.gov (United States)

    Amstrup, Steven C.; Douglas, David C.; Reynolds, Patricia E.; Rhode, E.B.

    2002-01-01

    Polar bears (Ursus maritimus) are hunted throughout most of their range. In addition to hunting polar bears of the Beaufort Sea region are exposed to mineral and petroleum extraction and related human activities such as shipping road-building, and seismic testing (Stirling 1990).Little was known at the start of this project about how polar bears move about in their environment, and although it was understood that many bears travel across political borders, the boundaries of populations had not been delineated (Amstrup 1986, Amstrup et al. 1986, Amstrup and DeMaster 1988, Garner et al. 1994, Amstrup 1995, Amstrup et al. 1995, Amstrup 2000).As human populations increase and demands for polar bears and other arctic resources escalate, managers must know the sizes and distributions of the polar bear populations. Resource managers also need reliable estimates of breeding rates, reproductive intervals, litter sizes, and survival of young and adults.Our objectives for this research were 1) to determine the seasonal and annual movements of polar bears in the Beaufort Sea, 2) to define the boundaries of the population(s) using this region, 3) to determine the size and status of the Beaufort Sea polar bear population, and 4) to establish reproduction and survival rates (Amstrup 2000).

  20. What 'empirical turn in bioethics'?

    Science.gov (United States)

    Hurst, Samia

    2010-10-01

    Uncertainty as to how we should articulate empirical data and normative reasoning seems to underlie most difficulties regarding the 'empirical turn' in bioethics. This article examines three different ways in which we could understand 'empirical turn'. Using real facts in normative reasoning is trivial and would not represent a 'turn'. Becoming an empirical discipline through a shift to the social and neurosciences would be a turn away from normative thinking, which we should not take. Conducting empirical research to inform normative reasoning is the usual meaning given to the term 'empirical turn'. In this sense, however, the turn is incomplete. Bioethics has imported methodological tools from empirical disciplines, but too often it has not imported the standards to which researchers in these disciplines are held. Integrating empirical and normative approaches also represents true added difficulties. Addressing these issues from the standpoint of debates on the fact-value distinction can cloud very real methodological concerns by displacing the debate to a level of abstraction where they need not be apparent. Ideally, empirical research in bioethics should meet standards for empirical and normative validity similar to those used in the source disciplines for these methods, and articulate these aspects clearly and appropriately. More modestly, criteria to ensure that none of these standards are completely left aside would improve the quality of empirical bioethics research and partly clear the air of critiques addressing its theoretical justification, when its rigour in the particularly difficult context of interdisciplinarity is what should be at stake.

  1. Accelerator terminal voltage stability

    Science.gov (United States)

    Ferry, J. A.; Kolonko, J. J.; Phillips, S. H.; Lunstrum, S. J.

    1992-02-01

    Measurements reported at the 11th International Conference on Applications of Accelerators in Research and Industry [Schroeder et al., Nucl. Instr. and Meth. B56/B57 (1991) 1033] for a 1 MV single-ended Pelletron accelerator equipped with corona probe and tank liner voltage stabilizers have been extended by measuring the resonant yield of γ-rays from the 27Al(p, γ) 28Si reaction at 992 keV. Results show that terminal voltage stability is consistent with the earlier measurement of 31 V FWHM for ripple at 1 MV for periods of about one-half ( {1}/{2}) hour.

  2. Accelerator terminal voltage stability

    International Nuclear Information System (INIS)

    Ferry, J.A.; Kolonko, J.J.; Phillips, S.H.; Lunstrum, S.J.

    1992-01-01

    Measurements reported at the 11th International Conference on Applications of Accelerators in Research and Industry for a 1 MV single-ended Pelletron accelerator equipped with corona probe and tank liner voltage stabilizers have been extended by measuring the resonant yield of γ-rays from the 27 Al(p,γ) 28 Si reaction at 992 keV. Results show that terminal voltage stability is consistent with the earlier measurement of 31 V FWHM for ripple at 1 MV for periods of about one-half (1/2) hour. (orig.)

  3. Turning rice meiosis into mitosis.

    Science.gov (United States)

    Mieulet, Delphine; Jolivet, Sylvie; Rivard, Maud; Cromer, Laurence; Vernet, Aurore; Mayonove, Pauline; Pereira, Lucie; Droc, Gaëtan; Courtois, Brigitte; Guiderdoni, Emmanuel; Mercier, Raphael

    2016-11-01

    Introduction of clonal reproduction through seeds (apomixis) in crops has the potential to revolutionize agriculture by allowing self-propagation of any elite variety, in particular F1 hybrids. In the sexual model plant Arabidopsis thaliana synthetic clonal reproduction through seeds can be artificially implemented by (i) combining three mutations to turn meiosis into mitosis (MiMe) and (ii) crossing the obtained clonal gametes with a line expressing modified CENH3 and whose genome is eliminated in the zygote. Here we show that additional combinations of mutations can turn Arabidopsis meiosis into mitosis and that a combination of three mutations in rice (Oryza sativa) efficiently turns meiosis into mitosis, leading to the production of male and female clonal diploid gametes in this major crop. Successful implementation of the MiMe technology in the phylogenetically distant eudicot Arabidopsis and monocot rice opens doors for its application to any flowering plant and paves the way for introducing apomixis in crop species.

  4. Digital voltage discriminator

    International Nuclear Information System (INIS)

    Zhou Zhicheng

    1992-01-01

    A digital voltage discriminator is described, which is synthesized by digital comparator and ADC. The threshold is program controllable with high stability. Digital region of confusion is approximately equal to 1.5 LSB. This discriminator has a single channel analyzer function model with channel width of 1.5 LSB

  5. Geomagnetism and Induced Voltage

    Science.gov (United States)

    Abdul-Razzaq, W.; Biller, R. D.

    2010-01-01

    Introductory physics laboratories have seen an influx of "conceptual integrated science" over time in their classrooms with elements of other sciences such as chemistry, biology, Earth science, and astronomy. We describe a laboratory to introduce this development, as it attracts attention to the voltage induced in the human brain as it…

  6. System for measuring of proton polarization in polarized target

    International Nuclear Information System (INIS)

    Derkach, A.Ya.; Lukhanin, A.A.; Karnaukhov, I.M.; Kuz'menko, V.S.; Telegin, Yu.N.; Trotsenko, V.I.; Chechetenko, V.F.

    1981-01-01

    Measurement system of proton polarization in the target, which uses the method of nuclear magnetic resonance is described. To record the signal of NMR-absorption a parallel Q-meter of voltage with analogous subtraction of resonance characteristics of measurement circuit is used. To obtain gradual sensitivity of the system to polarization state in the whole volume of the target the measurement coils is made of tape conductor. The analysis and mathematical modelling of Q-meter are carried out. Corrections for nonlinearity and dispersion are calculated. Key diagrams of the main electron blocks of Q-meter are presented. The system described operates on line with the M6000 computer. Total error of measurement of polarization value of free protons in the target does not exceed 6% [ru

  7. Stability Analysis and Controller Synthesis for Digital Single-Loop Voltage-Controlled Inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Loh, Poh Chiang; Blaabjerg, Frede

    2016-01-01

    This paper analyzes first the stability of single-loop digital voltage control scheme for the LC-filtered voltage source inverters. It turns out that the phase lag, caused by the time delay of digital control system and by the use of integral controller, can stabilize the voltage loop without...... damping of LC-filter resonance. The stability regions are then identified with alternative voltage controller synthesized. For further widening the stability region, an active damping approach is proposed and co-designed with the voltage controller in the discrete z-domain. Simulations and experimental...

  8. Professional Employees Turn to Unions

    Science.gov (United States)

    Chamot, Dennis

    1976-01-01

    White-collar and professional employees are increasingly turning to unions to combat their loss of independence as employees of large organizations. Managers should realize that they and professional employees have different viewpoints about job situations and that the current trend toward white-collar unionism is apt to continue. (JG)

  9. Hamilton's theory of turns revisited

    Indian Academy of Sciences (India)

    We present a new approach to Hamilton's theory of turns for the groups. SO(3) and SU(2) which renders their properties, in particular their composition law, nearly trivial and immediately evident upon inspection. We show that the entire con- struction can be based on binary rotations rather than mirror reflections. Keywords.

  10. The Philosophy of Turning Points

    DEFF Research Database (Denmark)

    Turcan, Romeo V.

    2013-01-01

    This paper introduces and discusses the concept of turning points from the ontological, epistemological, and methodological perspectives, applying it to the de-internationalization phenomenon to exemplify its deployment. As a concept that adds to the variance and complexity of the international b...

  11. Why Does Hair Turn Gray?

    Science.gov (United States)

    ... out, but people with naturally lighter hair are just as likely to go gray. From the time a person notices a few gray hairs, it may take more than 10 years for all of that person's hair to turn ... really believe that this happens. Just in case, try not to freak out your ...

  12. Phenomenology and the Empirical Turn

    NARCIS (Netherlands)

    Zwier, Jochem; Blok, Vincent; Lemmens, Pieter

    2016-01-01

    This paper provides a phenomenological analysis of postphenomenological philosophy of technology. While acknowledging that the results of its analyses are to be recognized as original, insightful, and valuable, we will argue that in its execution of the empirical turn, postphenomenology forfeits

  13. Hamilton's theory of turns revisited

    Indian Academy of Sciences (India)

    MS received 16 July 2009; accepted 1 September 2009. Abstract. We present a new approach to Hamilton's theory of turns for the groups. SO(3) and SU(2) which renders their properties, in particular their composition law, nearly trivial and immediately evident upon inspection. We show that the entire con- struction can be ...

  14. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  15. High voltage generator

    Science.gov (United States)

    Schwemin, A. J.

    1959-03-17

    A generator for producing relatively large currents at high voltages is described. In general, the invention comprises a plurality of capacitors connected in series by a plurality of switches alternately disposed with the capacitors. The above-noted circuit is mounted for movement with respect to contact members and switch closure means so that a load device and power supply are connected across successive numbers of capacitors, while the other capacitors are successively charged with the same power supply.

  16. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  17. High voltage pulse conditioning

    International Nuclear Information System (INIS)

    Springfield, R.M.; Wheat, R.M.

    1990-01-01

    This patent describes an apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close

  18. High voltage electrical injuries

    International Nuclear Information System (INIS)

    Janjua, S.A.

    2002-01-01

    Objective: To highlight the devastating nature and consequences of high voltage electrical injuries and to stress the need for its prevention. Design: It was a retrospective study. Place and duration of study: The study was conducted at Army Burn Centre, Combined Military Hospital Kharian Cantonment, between January 1,1998 to December 31, 2000. Subjects and Methods: All the patients reporting to Army Burn Centre with high voltage electrical injuries were included in the study. The epidemiology of these injuries were studied along with the pattern of their management and outcome in terms of mortality and morbidity. Results: Of all the patients admitted to the Army Burn Center, 5.94% were affected with electrical injuries. They were predominantly males in a ratio of 9.75:1 and mostly in the 3rd and 4th decades of their lives. Seventy percent of these injuries were injuries were work-related and 75% had associated surface burns. There was significant mortality rate of 18.6% and a limb amputation rate of 80% along with professional disability rate of 91% rendering it a highly morbid condition. Conclusion: This study stresses the necessity to educate the general public with regard to the devastating nature of high voltage electrical injury and highlight the importance of prevention. (author)

  19. Political polarization

    OpenAIRE

    Dixit, Avinash K.; Weibull, Jörgen W.

    2007-01-01

    Failures of government policies often provoke opposite reactions from citizens; some call for a reversal of the policy, whereas others favor its continuation in stronger form. We offer an explanation of such polarization, based on a natural bimodality of preferences in political and economic contexts and consistent with Bayesian rationality.

  20. Political polarization.

    Science.gov (United States)

    Dixit, Avinash K; Weibull, Jörgen W

    2007-05-01

    Failures of government policies often provoke opposite reactions from citizens; some call for a reversal of the policy, whereas others favor its continuation in stronger form. We offer an explanation of such polarization, based on a natural bimodality of preferences in political and economic contexts and consistent with Bayesian rationality.

  1. Opposed turns at signalized intersections

    Energy Technology Data Exchange (ETDEWEB)

    Akcelik, R.

    1989-06-01

    The 1985 Highway Capacity Manual (HCM) brought the U.S. and Australian methodologies for signalized intersections closer together. An important element in this methodology is the techniques used for the estimation of opposed (permissive) turn saturation flows. Although the basic modeling philosophies of the HCM and Australian methods are similar, there are significant differences in the procedures used and therefore in the results from the two methods. In particular, the latest methodology employed in the SIDRA software has eliminated the use of opposed turn adjustment factors for lane groups and adopted an explicit and direct method of modeling individual lanes. The purpose of this paper is to bring these new methods to the attention of the U.S. researchers since it is understood that efforts are being made to improve the 1985 HCM method.

  2. Diamond turning machine controller implementation

    Energy Technology Data Exchange (ETDEWEB)

    Garrard, K.P.; Taylor, L.W.; Knight, B.F.; Fornaro, R.J.

    1988-12-01

    The standard controller for a Pnuemo ASG 2500 Diamond Turning Machine, an Allen Bradley 8200, has been replaced with a custom high-performance design. This controller consists of four major components. Axis position feedback information is provided by a Zygo Axiom 2/20 laser interferometer with 0.1 micro-inch resolution. Hardware interface logic couples the computers digital and analog I/O channels to the diamond turning machine`s analog motor controllers, the laser interferometer, and other machine status and control information. It also provides front panel switches for operator override of the computer controller and implement the emergency stop sequence. The remaining two components, the control computer hardware and software, are discussed in detail below.

  3. Mitigation of Voltage Sags in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    Any problem in voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM), Dynamic Voltage Restorer (DVR) etc. are commonly used for the mitigation of voltage p....... The compensation of voltage sags in the different parts of CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0....

  4. Suppressing voltage transients in high voltage power supplies

    International Nuclear Information System (INIS)

    Lickel, K.F.; Stonebank, R.

    1979-01-01

    A high voltage power supply for an X-ray tubes includes voltage adjusting means, a high voltage transformer, switch means connected to make and interrupt the primary current of the transformer, and over-voltage suppression means to suppress the voltage transient produced when the current is switched on. In order to reduce the power losses in the suppression means, an impedance is connected in the transformer primary circuit on operation of the switch means and is subsequently short-circuited by a switch controlled by a timer after a period which is automatically adjusted to the duration of the transient overvoltage. (U.K.)

  5. Diamond turning of thermoplastic polymers

    Energy Technology Data Exchange (ETDEWEB)

    Smith, E.; Scattergood, R.O.

    1988-12-01

    Single point diamond turning studies were made using a series of thermoplastic polymers with different glass transition temperatures. Variations in surface morphology and surface roughness were observed as a function of cutting speed. Lower glass transition temperatures facilitate smoother surface cuts and better surface finish. This can be attributed to the frictional heating that occurs during machining. Because of the very low glass transition temperatures in polymeric compared to inorganic glasses, the precision machining response can be very speed sensitive.

  6. Turning points in reactor design

    Energy Technology Data Exchange (ETDEWEB)

    Beckjord, E.S.

    1995-09-01

    This article provides some historical aspects on nuclear reactor design, beginning with PWR development for Naval Propulsion and the first commercial application at Yankee Rowe. Five turning points in reactor design and some safety problems associated with them are reviewed: (1) stability of Dresden-1, (2) ECCS, (3) PRA, (4) TMI-2, and (5) advanced passive LWR designs. While the emphasis is on the thermal-hydraulic aspects, the discussion is also about reactor systems.

  7. Turning points in reactor design

    International Nuclear Information System (INIS)

    Beckjord, E.S.

    1995-01-01

    This article provides some historical aspects on nuclear reactor design, beginning with PWR development for Naval Propulsion and the first commercial application at Yankee Rowe. Five turning points in reactor design and some safety problems associated with them are reviewed: (1) stability of Dresden-1, (2) ECCS, (3) PRA, (4) TMI-2, and (5) advanced passive LWR designs. While the emphasis is on the thermal-hydraulic aspects, the discussion is also about reactor systems

  8. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P [Albuquerque, NM; Christenson, Todd R [Albuquerque, NM

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  9. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...

  10. Electrical polarization of lead bromide crystals. II

    NARCIS (Netherlands)

    Schoonman, J.; Dijkman, F.G.

    Electrical currents are measured as a function of time after application of a dc voltage on a cell arragement +C/PbBr2/C-. The presence of nonlinear polarization phenomena has been established from a test of Ohm's law, the superposition principle, and from initial and steady-state conductivities

  11. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  12. Regulation of cell polarity by cell adhesion receptors.

    Science.gov (United States)

    Ebnet, Klaus; Kummer, Daniel; Steinbacher, Tim; Singh, Amrita; Nakayama, Masanori; Matis, Maja

    2017-07-22

    The ability of cells to polarize is an intrinsic property of almost all cells and is required for the devlopment of most multicellular organisms. To develop cell polarity, cells integrate various signals derived from intrinsic as well as extrinsic sources. In the recent years, cell-cell adhesion receptors have turned out as important regulators of cellular polarization. By interacting with conserved cell polarity proteins, they regulate the recruitment of polarity complexes to specific sites of cell-cell adhesion. By initiating intracellular signaling cascades at those sites, they trigger their specific subcellular activation. Not surprisingly, cell-cell adhesion receptors regulate diverse aspects of cell polarity, including apico-basal polarity in epithelial and endothelial cells, front-to-rear polarity in collectively migrating cells, and planar cell polarity during organ development. Here, we review the recent developments highlighting the central roles of cell-cell adhesion molecules in the development of cell polarity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. The affective turn in ethnomusicology

    Directory of Open Access Journals (Sweden)

    Hofman Ana

    2015-01-01

    Full Text Available The affective turn, which has already questioned dominant paradigms in many disciplinary fields including cultural studies, philosophy, political theory, anthropology, psychology and neuroscience, has started to attract more attention in the field of ethnomusicology, becoming a particularly vibrant stream of thought. Drawing on the voices that call for the historicisation of and critical deliberation on the field of affect studies, the article strives to show how theories of affect might expand dominant paradigms in ethnomusicology and also points to their limitations.

  14. Design and Implementation of a High-Voltage Generator with Output Voltage Control for Vehicle ER Shock-Absorber Applications

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2013-01-01

    Full Text Available A self-oscillating high-voltage generator is proposed to supply voltage for a suspension system in order to control the damping force of an electrorheological (ER fluid shock absorber. By controlling the output voltage level of the generator, the damping force in the ER fluid shock absorber can be adjusted immediately. The shock absorber is part of the suspension system. The high-voltage generator drives a power transistor based on self-excited oscillation, which converts dc to ac. A high-frequency transformer with high turns ratio is used to increase the voltage. In addition, the system uses the car battery as dc power supply. By regulating the duty cycle of the main switch in the buck converter, the output voltage of the buck converter can be linearly adjusted so as to obtain a specific high voltage for ER. The driving system is self-excited; that is, no additional external driving circuit is required. Thus, it reduces cost and simplifies system structure. A prototype version of the actual product is studied to measure and evaluate the key waveforms. The feasibility of the proposed system is verified based on experimental results.

  15. Heat-pump performance: voltage dip/sag, under-voltage and over-voltage

    Directory of Open Access Journals (Sweden)

    William J.B. Heffernan

    2014-12-01

    Full Text Available Reverse cycle air-source heat-pumps are an increasingly significant load in New Zealand and in many other countries. This has raised concern over the impact wide-spread use of heat-pumps may have on the grid. The characteristics of the loads connected to the power system are changing because of heat-pumps. Their performance during under-voltage events such as voltage dips has the potential to compound the event and possibly cause voltage collapse. In this study, results from testing six heat-pumps are presented to assess their performance at various voltages and hence their impact on voltage stability.

  16. A new Zero-Voltage-Transition PWM switching cell

    Energy Technology Data Exchange (ETDEWEB)

    Grigore, V. [Electronics and Telecommunications Faculty `Politebuica` University Bucharest (Romania); Kyyrae, J. [Helsinki University of Technology, Otaniemi (Finland): Institute of Intelligent Power Electronics

    1997-12-31

    In this paper a new Zero-Voltage-Transition (ZVT) PWM switching cell is presented. The proposed switching cell is composed of the normal hard-switched PWM cell (consisting of one active switch and one passive switch), plus an auxiliary circuit (consisting of one active switch and some reactive components). The auxiliary circuit is inactive during the ON and OFF intervals of the switches in the normal PWM switch. However, the transitions between the two states are controlled by the auxiliary circuit. Prior to turn-on, the voltage across the active switch in the PWM cell is forced to zero, thus the turn-on losses of the active switch are practically eliminated. At turn-off the auxiliary circuit behaves like a non-dissipative passive snubber reducing the turn-off losses to a great extent. Zero-Voltage-Transition switching technique almost eliminates switching losses. The active switch operates under ZVT conditions, the passive switch (diode) has a controlled reverse recovery, and the switch in the auxiliary circuit operates under Zero-Current-Switching (ZCS) conditions. (orig.) 6 refs.

  17. On the cause and control of residual voltage generated by electrical stimulation of neural tissue.

    Science.gov (United States)

    Krishnan, Ashwati; Kelly, Shawn K

    2012-01-01

    Functional electrical stimulation of neural tissue is traditionally performed with symmetric cathodic-first biphasic pulses of current through an electrode/electrolyte interface. When the interface is modeled by a series R-C circuit, as is sometimes done for stimulator circuit design, the appearance of a net residual voltage across the electrode cannot be explained. Residual voltage can cause polarization of the electrode and pose a problem for safe electrical stimulation. This paper aims to (1) theoretically explain one reason for the residual voltage, which is the inclusion of the Faradaic impedance (2) suggest a simple dynamic feedback mechanism to eliminate residual voltage.

  18. Spin-polarized light-emitting diodes based on organic bipolar spin valves

    Energy Technology Data Exchange (ETDEWEB)

    Vardeny, Zeev Valentine; Nguyen, Tho Duc; Ehrenfreund, Eitan Avraham

    2017-10-25

    Spin-polarized organic light-emitting diodes are provided. Such spin-polarized organic light-emitting diodes incorporate ferromagnetic electrodes and show considerable spin-valve magneto-electroluminescence and magneto-conductivity responses, with voltage and temperature dependencies that originate from the bipolar spin-polarized space charge limited current.

  19. Turning nuclear communications inside out

    International Nuclear Information System (INIS)

    Besenyei, Elisabeth; Czibolya, Laszlo

    2002-01-01

    Due to debates on the security of energy supply in the European Union, the international efforts on the implementation of Kyoto protocol and the forthcoming liberalization of the electrical energy market the attention of Hungarian decision-makers was focused on energy related problems. Discussions started on the future role of nuclear power and anti-nuclear environmentalists became more active in their criticism. Changes were needed in the approach and practice of communication on nuclear energy. Previous practice turned to be inefficient in dialogue with different social and influential groups. Public information could not be considered any more as an activity explaining measures to cope with incidents and accidents or giving technical answers to mostly superficial statements on allegedly unsafe features and solutions in nuclear industry. It was time to change the paradigm and to turn the communication into a powerful tool to put forward the arguments, to show the achievements and facts and to explain the efforts in addressing public concerns. The new paradigm turned the previous outside-in approach to a new inside-out type of behavior. Instead of reacting to the attacks coming from outside the new approach means first of all commitment to be open and pro-active in communication and to act in close cooperation with all interested organizations and institutions. The three pillars of the new paradigm, commitment, communication and co-operation are applicable not only for the nuclear industry, but also for the governmental agencies (regulatory bodies, health and emergency authorities etc.) and for the wide range of technical, scientific and civil organizations. Public information should be turned from a burden to a challenge for open, technically valid and honest dialogue. This active communication approach is illustrated by some new initiatives in public information in Hungary. Following the successful Nuclear Academy for Journalists formed new Section of Nuclear

  20. Strategic Polarization.

    Science.gov (United States)

    Kalai, Adam; Kalai, Ehud

    2001-08-01

    In joint decision making, similarly minded people may take opposite positions. Consider the example of a marriage in which one spouse gives generously to charity while the other donates nothing. Such "polarization" may misrepresent what is, in actuality, a small discrepancy in preferences. It may be that the donating spouse would like to see 10% of their combined income go to charity each year, while the apparently frugal spouse would like to see 8% donated. A simple game-theoretic analysis suggests that the spouses will end up donating 10% and 0%, respectively. By generalizing this argument to a larger class of games, we provide strategic justification for polarization in many situations such as debates, shared living accommodations, and disciplining children. In some of these examples, an arbitrarily small disagreement in preferences leads to an arbitrarily large loss in utility for all participants. Such small disagreements may also destabilize what, from game-theoretic point of view, is a very stable equilibrium. Copyright 2001 Academic Press.

  1. Fast turn-on of an NMOS ESD protection transistor: measurements and simulations

    NARCIS (Netherlands)

    Luchies, J.R.M.; Luchies, J.R.M.; de Kort, C.G.M.; Verweij, J.F.; Verweij, J.F.

    1995-01-01

    The transient turn-on of the parasitic bipolar transistor of an NMOS transistor was studied. The voltages appearing at internal nodes of protection and functional circuit after application of 350 ps rise-time pulses have been measured using electro-optic sampling. For very fast transients the

  2. Characteristics of output voltage and current of integrated nanogenerators

    KAUST Repository

    Yang, Rusen

    2009-01-01

    Owing to the anisotropic property and small output signals of the piezoelectric nanogenerators (NGs) and the influence of the measurement system and environment, identification of the true signal generated by the NG is critical. We have developed three criteria: Schottky behavior test, switching-polarity tests, and linear superposition of current and voltage tests. The 11 tests can effectively rule out the system artifacts, whose sign does not change with the switching measurement polarity, and random signals, which might change signs but cannot consistently add up or cancel out under designed connection configurations. This study establishes the standards for designing and scale up of integrated nanogenerators. © 2009 American Institute of Physics.

  3. The ILC polarized electron source

    CERN Document Server

    Brachmann, Axel; Garwin, Edward; Kirby, Robert; Luh Dah An; Maruyama, Takashi; Prepost, Richard; Schultz, David; Sheppard, John

    2005-01-01

    The SLC polarized electron source (PES) can meet the expected requirements of the International Linear Collider (ILC) for polarization, charge and lifetime. However, experience with newer and successful PES designs at JLAB, Mainz and elsewhere can be incorporated into a first-generation ILC source that will emphasize reliability and stability without compromising the photocathode performance. The long pulse train for the ILC may introduce new challenges for the PES, and in addition more reliable and stable operation of the PES may be achievable if appropriate R&D is carried out for higher voltage operation and for a simpler load-lock system. The outline of the R&D program currently taking shape at SLAC and elsewhere is discussed. The principal components of the proposed ILC PES, including the laser system necessary for operational tests, are described.

  4. Voltage Dependence of Supercapacitor Capacitance

    Directory of Open Access Journals (Sweden)

    Szewczyk Arkadiusz

    2016-09-01

    Full Text Available Electronic Double-Layer Capacitors (EDLC, called Supercapacitors (SC, are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We propose an experimental method, based on monitoring of charging and discharging a supercapacitor, which enables to evaluate the charge in an SC structure as well as the Capacitance-Voltage (C-V dependence. The measurement setup, method and experimental results of charging/discharging commercially available supercapacitors in various voltage and current conditions are presented. The total charge stored in an SC structure is proportional to the square of voltage at SC electrodes while the charge on electrodes increases linearly with the voltage on SC electrodes. The Helmholtz capacitance increases linearly with the voltage bias while a sublinear increase of total capacitance was found. The voltage on SC increases after the discharge of electrodes due to diffusion of charges from the electrolyte to the electrodes. We have found that the recovery voltage value is linearly proportional to the initial bias voltage value.

  5. Capacitor storage voltage stabilization device

    International Nuclear Information System (INIS)

    Logvin, V.V.; Gusev, E.V.

    1987-01-01

    An electric circuit of a device designed for charging and stabilizing a capacitor storage is described. A phase-pulse method for thyristor control in the power transformer first circuit is used. In the process of storage charging the triggering angle of thyristors linearly grows, that excludes the necessity of application of current-limiting elements in the charging circuit. The averaged charging voltage of the storage linearly dependce on charging time. Charging is realized by a series of short-time current pulses. Output voltage is controlled within 10...95% limits of the rated value. Voltage instability is ≤0.5% at power supply voltage variation of ±10%

  6. Mechano-capacitive properties of polarized membranes.

    Science.gov (United States)

    Mosgaard, Lars D; Zecchi, Karis A; Heimburg, Thomas

    2015-10-28

    Biological membranes are capacitors that can be charged by applying a field across the membrane. The charges on the capacitor exert a force on the membrane that leads to electrostriction, i.e. a thinning of the membrane. Since the force is quadratic in voltage, negative and positive voltage have an identical influence on the physics of symmetric membranes. However, this is not the case for a membrane with an asymmetry leading to a permanent electric polarization. Positive and negative voltages of identical magnitude lead to different properties. Such an asymmetry can originate from a lipid composition that is different on the two monolayers of the membrane, or from membrane curvature. The latter effect is called 'flexoelectricity'. As a consequence of permanent polarization, the membrane capacitor is discharged at a voltage different from zero. This leads to interesting electrical phenomena such as outward or inward rectification of membrane permeability. Here, we introduce a generalized theoretical framework, that treats capacitance, polarization, flexoelectricity, piezoelectricity and thermoelectricity in the same language. We show applications to electrostriction, membrane permeability and piezoelectricity and thermoelectricity close to melting transitions, where such effects are especially pronounced.

  7. Projective geometry for polarization in geometric quantization

    International Nuclear Information System (INIS)

    Campbell, P.; Dodson, C.T.J.

    1976-12-01

    It is important to know the extent to which the procedure of geometric quantization depends on a choice of polarization of the symplectic manifold that is the classical phase space. Published results have so far been restricted to real and transversal polarizations. Here we also consider these cases by presenting a formulation in terms of projective geometry. It turns out that there is a natural characterization of real transversal polarizations and maps among them using projective concepts. We give explicit constructions for Rsup(2n)

  8. Temporary over voltages in the high voltage networks

    International Nuclear Information System (INIS)

    Vukelja, Petar; Naumov, Radomir; Mrvic, Jovan; Minovski, Risto

    2001-01-01

    The paper treats the temporary over voltages that may arise in the high voltage networks as a result of: ground faults, loss of load, loss of one or two phases and switching operation. Based on the analysis, the measures for their limitation are proposed. (Original)

  9. Influences of surface and flexoelectric polarization on the effective anchoring energy in nematic liquid crystal

    International Nuclear Information System (INIS)

    Guan Rong-Hua; Ye Wen-Jiang; Xing Hong-Yu

    2015-01-01

    The physical effects on surface and flexoelectric polarization in a weak anchoring nematic liquid crystal cell are investigated systematically. We derive the analytic expressions of two effective anchoring energies for lower and upper substrates respectively as well as their effective anchoring strengths and corresponding tilt angles of effective easy direction. All of these quantities are relevant to the magnitudes of both two polarizations and the applied voltage U. Based on these expressions, the variations of effective anchoring strength and the tilt angle with the applied voltage are calculated for the fixed values of two polarizations. For an original weak anchoring hybrid aligned nematic cell, it may be equivalent to a planar cell for a small value of U and has a threshold voltage. The variation of reduced threshold voltage with reduced surface polarization strength is also calculated. The role of surface polarization is important without the adsorptive ions considered. (paper)

  10. Nuclear reactivity control using laser induced polarization

    International Nuclear Information System (INIS)

    Bowman, C.D.

    1990-01-01

    This patent describes a control element for reactivity control of a fission source provides an atomic density of 3 He in a control volume which is effective to control criticality as the 3 He is spin-polarized. Spin-polarization of the 3 He affects the cross section of the control volume for fission neutrons and hence, the reactivity. An irradiation source is directed within the 3 He for spin-polarizing the 3 He. An alkali-metal vapor may be included with the 3 He where a laser spin-polarizes the alkali-metal atoms which in turn, spin-couple with 3 He to spin-polarize the 3 He atoms

  11. Polar transport in plants mediated by membrane transporters: focus on mechanisms of polar auxin transport.

    Science.gov (United States)

    Naramoto, Satoshi

    2017-12-01

    Directional cell-to-cell transport of functional molecules, called polar transport, enables plants to sense and respond to developmental and environmental signals. Transporters that localize to plasma membranes (PMs) in a polar manner are key components of these systems. PIN-FORMED (PIN) auxin efflux carriers, which are the most studied polar-localized PM proteins, are implicated in the polar transport of auxin that in turn regulates plant development and tropic growth. In this review, the regulatory mechanisms underlying polar localization of PINs, control of auxin efflux activity, and PIN abundance at PMs are considered. Up to date information on polar-localized nutrient transporters that regulate directional nutrient movement from soil into the root vasculature is also discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. 1.06 μm 150 psec laser damage study of diamond turned, diamond turned/polished and polished metal mirrors

    International Nuclear Information System (INIS)

    Saito, T.T.; Milam, D.; Baker, P.; Murphy, G.

    1975-01-01

    Using a well characterized 1.06 μm 150 ps glass laser pulse the damage characteristics for diamond turned, diamond turned/ polished, and polished copper and silver mirrors less than 5 cm diameter were studied. Although most samples were tested with a normal angle of incidence, some were tested at 45 0 with different linear polarization showing an increase in damage threshold for S polarization. Different damage mechanisms observed will be discussed. Laser damage is related to residual surface influences of the fabrication process. First attempts to polish diamond turned surfaces resulted in a significant decrease in laser damage threshold. The importance of including the heat of fusion in the one dimensional heat analysis of the theoretical damage threshold and how close the samples came to the theoretical damage threshold is discussed. (auth)

  13. William Friedman, Geneticist Turned Cryptographer.

    Science.gov (United States)

    Goldman, Irwin L

    2017-05-01

    William Friedman (1891-1969), trained as a plant geneticist at Cornell University, was employed at Riverbank Laboratories by the eccentric millionaire George Fabyan to work on wheat breeding. Friedman, however, soon became intrigued by and started working on a pet project of Fabyan's involving the conjecture that Francis Bacon, a polymath known for the study of ciphers, was the real author of Shakespeare's plays. Thus, beginning in ∼1916, Friedman turned his attention to the so called "Baconian cipher," and developed decryption techniques that bore similarity to approaches for solving problems in population genetics. His most significant, indeed pathbreaking, work used ideas from genetics and statistics, focusing on analysis of the frequencies of letters in language use. Although he had transitioned from being a geneticist to a cryptographer, his earlier work had resonance in his later pursuits. He soon began working directly for the United States government and produced solutions used to solve complex military ciphers, in particular to break the Japanese Purple code during World War II. Another important legacy of his work was the establishment of the Signal Intelligence Service and eventually the National Security Agency. Copyright © 2017 by the Genetics Society of America.

  14. Notes on the Spatial Turn

    Directory of Open Access Journals (Sweden)

    Stipe Grgas

    2012-06-01

    Full Text Available On the basis of ever-mounting evidence, amongst which is the “zone” problematic of the Zadar conference that occassioned these notes, it can be concluded that the spatial turn has insinuated itself as an all-pervading heuristic tool throughout the humanities and the social sciences. The extent to which space and spatiality have usurped the central stage in the various branches of reasearch can be gauged by admonishments that what we are witnessing is a new fundamentalism that has simply inverted the terms of the dualism of time and space (May and Thrift 2001: “Introduction”. According to Michael Dear the sway of space is manifested in multifold ways: in the ubiquity of spatial analysis in social theories and practices; in the explosion of publications devoted to the exploration of the interface of the social and the spatial; in the reintegration of human geography into various domains of knowledge; in the focus given to difference and the consequent diversification of theoretical and empirical practices; in a theoretically informed exploration of the relation between geographical knowledge and social action; and, finally, in the unprecedented proliferation of research agendas and publications pertaining to these isuuses (Dear 2001: 24. Two recent collections of papers are indicative of the ubiquity of spatial issues in scholarly work.

  15. Wide Input Range Power Converters Using a Variable Turns Ratio Transformer

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2016-01-01

    of diagonal secondary windings, in order to make the transformer turns ratio adjustable by controlling the phase between the two current excitations subjected to the two primary windings. Full-bridge boost dc-dc converter is employed with the proposed transformer to demonstrate the feasibility of the variable......A new integrated transformer with variable turns ratio is proposed to enable dc-dc converters operating over a wide input voltage range. The integrated transformer employs a new geometry of magnetic core with “four legs”, two primary windings with orthogonal arrangement, and “8” shape connection...... turns ratio. 1-kW experimental prototype targeting to the PV standalone system has been built to well demonstrate a wide input voltage operation with high efficiencies....

  16. Voltage Controlled Dynamic Demand Response

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    Future power system is expected to be characterized by increased penetration of intermittent sources. Random and rapid fluctuations in demands together with intermittency in generation impose new challenges for power balancing in the existing system. Conventional techniques of balancing by large...... central or dispersed generations might not be sufficient for future scenario. One of the effective methods to cope with this scenario is to enable demand response. This paper proposes a dynamic voltage regulation based demand response technique to be applied in low voltage (LV) distribution feeders....... An adaptive dynamic model has been developed to determine composite voltage dependency of an aggregated load on feeder level. Following the demand dispatch or control signal, optimum voltage setting at the LV substation is determined based on the voltage dependency of the load. Furthermore, a new technique...

  17. SYNTHESIS OF VOLTAGES OF UNIFORM PWM IN TIME REGULATION

    Directory of Open Access Journals (Sweden)

    A. G. Stryzhniou

    2014-01-01

    Full Text Available The article describes a process of synthesis and qualitative assessment of the harmonic composition of voltages of multiple and single PWM pulses in time regulation, being, along with amplitude, frequency and phase method, one of control methods of an asynchronous motor. The main point of time regulation is that a pause after any two single PWM pulses with different polarity or after any two groups of multiple PWM pulses with different polarity changes during a process of regulation. Feature of time regulation is that a motor has fast response in the range of small-signal of control and good linearity of speed-torque characteristics in the whole control range. Analytical expressions of parameters of PWM pulses ai and ti are obtained which allow to simplify considerably a process of formation and implementation of time regulation using tabular or indexed-tabular methods. These expressions allow not only to define voltage amplitude of  harmonic but also to perform qualitative assessment of harmonic composition of output voltages at time regulation. It is specified that harmonic frequencies wi = w0/q change in inverse proportion to magnitude of parameter q during a process of regulation and there is a replacement of a fundamental frequency by frequencies of higher harmonics.The offered approach allows to synthesize voltage of uniform single and multiple PWM pulses and to perform their comparative and qualitative analysis and the obtained expressions can be used at modeling of AC motor work. Voltage of multiple PWM pulses which is formed using stepped reference voltage with even quantity of steps in a half period and a pause on a zero level has the best parameters by criterion of a minimum of harmonic components and a maximum of a factor of anharmonicity Kнс at time regulation.

  18. Clinical evaluation of an automated turning bed.

    Science.gov (United States)

    Melland, H I; Langemo, D; Hanson, D; Olson, B; Hunter, S

    1999-01-01

    The purposes of this study were to assess client comfort and sleep quality, client physiologic response (skin and respiratory status), the effect on the need for caregiver assistance, and cost when using an automated turning bed. Nonexperimental, evaluative study. Twenty-four adult home or long-term care resident subjects who had a degenerative disease, spinal cord injury, stroke, cerebral palsy, or back surgery. Each subject agreed to use the automated turning bed for four weeks. Researchers completed a demographic survey and skin assessment, and assessed each subject for pressure ulcer risk and for the need of assistance of a care giver for turning before and after the four weeks of using the turning bed. Subjects rated the turning bed in terms of comfort and sleep quality. Subjects rated the turning bed as more comfortable than their own bed and expressed satisfaction at the pain relief attained when on the turning bed. While using the turning bed, there was a significant improvement in sleep quality. No skin breakdown or deterioration in respiratory status occurred. Fewer subjects required the assistance of a caregiver for turning when on the turning bed. This automated turning bed shows great promise in meeting a need for patients with limited mobility whether they are homebound or in a residential community. Future studies that further investigate use of the turning bed for postoperative back patients while still in the acute care setting are indicated. Replicative studies with a larger sample size are also indicated.

  19. 32 CFR 636.23 - Turning movements.

    Science.gov (United States)

    2010-07-01

    ... Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL... movements. (a) U-turns are prohibited on all streets in the cantonment area. (b) Right-turns will be made from a position as close to the right edge or right curb of the roadway as possible. (c) Left-turns...

  20. Cavity Voltage Phase Modulation MD blocks 3 and 4

    CERN Document Server

    Mastoridis, T; Butterworth, A; Molendijk, J; Tuckmantel, J

    2013-01-01

    The LHC RF/LLRF system is currently setup for extremely stable RF voltage to minimize transient beam loading effects. The present scheme cannot be extended beyond nominal beam current since the demanded power would push the klystrons to saturation. For beam currents above nominal (and possibly earlier), the cavity phase modulation by the beam (transient beam loading) will not be corrected, but the strong RF feedback and One-Turn Delay feedback will still be active for RF loop and beam stability in physics. To achieve this, the voltage set point should be adapted for each bunch. The goal of these MDs was to test thefirmware version of an iterative algorithm that adjusts the voltage set point to achieve the optimal phase modulation for klystron forward power considerations.

  1. Precessing deuteron polarization

    International Nuclear Information System (INIS)

    Sitnik, I.M.; Volkov, V.I.; Kirillov, D.A.; Piskunov, N.M.; Plis, Yu.A.

    2002-01-01

    The feasibility of the acceleration in the Nuclotron of deuterons polarized in the horizontal plane is considered. This horizontal polarization is named precessing polarization. The effects of the main magnetic field and synchrotron oscillations are included. The precessing polarization is supposed to be used in studying the polarization parameters of the elastic dp back-scattering and other experiments

  2. Voltage asymmetry in the current-voltage characteristics of granular YBa2Cu3O

    International Nuclear Information System (INIS)

    Gonzalez, M. T.; Curras, S. R.; Maza, J.; Vidal, F.

    2001-01-01

    We study the current-voltage characteristics (CVC's) in granular YBa 2 Cu 3 O 7-δ under applied magnetic fields with an amplitude and a spatial distribution similar to the self-fields generated by the transport currents. By this way, a proper compensating procedure between both fields has allowed us to obtain CVC's at a very low constant resultant field. To that end, hollow cylinder-shaped samples were axially threaded by an external wire in a counter-current setup. The measurement procedure lay in applying a variable magnetic field by the external wire compensating the increasing self-field. CVC's in the range 2 - 20 Oe, even below the sample self-field, were thus obtained, with voltage spanning three orders of magnitude. A relevant result from these measurements is the different voltage values observed for resultant field distributions of the same root-mean-square volume average but opposite azimuthal polarity. This asymmetry may find an explanation in terms of a concentration of the current in between the grains giving an effective magnetic field different from the macroscopic field. An expression for the effective magnetic field that accounts quantitatively for the data is put forward

  3. Self-polarizing terahertz liquid crystal phase shifter

    Directory of Open Access Journals (Sweden)

    Xiao-wen Lin

    2011-09-01

    Full Text Available Using sub-wavelength metallic gratings as both transparent electrodes and broadband high-efficiency polarizers, a highly-compact self-polarizing phase shifter is demonstrated by electrically tuning the effective birefringence of a nematic liquid crystal cell. The metal grating polarizers ensure a good polarizing efficiency in the range of 0.2 to 2 THz. Phase shift of more than π/3 is achieved in a 256 μm-thick cell with a saturation root mean square voltage of around 130 V in this integrated device.

  4. Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    to unbalanced faults. The compensation of unbalanced voltage sags and voltage unbalance in the CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0....

  5. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    on measured local voltages. The advantage of the proposed method is that the calculated reactive power and active power droop settings enable fair contribution of the PV inverters at each node to the voltage regulation. Simulation studies are conducted using DigSilent Power factory software on a simplified...

  6. Polare maskuliniteter

    Directory of Open Access Journals (Sweden)

    Marit Anne Hauan

    2012-05-01

    Full Text Available In this paper my aim is to read and understand the journal of Gerrit de Veer from the last journey of William Barents to the Arctic Regions in 1596 and the journal of captain Junge on his hunting trip from Tromsø to Svalbard in 1834.It is nearly 240 years between this to voyages. The first journal is known as the earliest report from the arctic era. Gerrit de Veer adds instructive copper engravings to his text and give us insight in the crews meeting with this new land. Captain Junges journal is found together with his dead crew in a house in a fjord nearby Ny-Ålesund and has no drawings, but word. Both of these journals may be read as sources of the knowledge and understanding of the polar region. They might also unveil the ideas of how to deal with and survive under the challenges that is given. In addition one can ask if the sources can tell us more about how men describe their challenges. Can the way they expressed themselves in the journals give us an understanding of masculinity? And not least help us to create good questions of the change in the ideas of masculinities which is said to follow the change in understanding of the wilderness.

  7. Polarized electron sources for linear colliders

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Ecklund, S.D.; Miller, R.H.; Schultz, D.C.; Sheppard, J.C.

    1992-07-01

    Linear colliders require high peak current beams with low duty factors. Several methods to produce polarized e - beams for accelerators have been developed. The SLC, the first linear collider, utilizes a photocathode gun with a GaAs cathode. Although photocathode sources are probably the only practical alternative for the next generation of linear colliders, several problems remain to be solved, including high voltage breakdown which poisons the cathode, charge limitations that are associated with the condition of the semiconductor cathode, and a relatively low polarization of ≤5O%. Methods to solve or at least greatly reduce the impact of each of these problems are at hand

  8. Voltage-controlled optical switch in planar nematic liquid crystal film

    Science.gov (United States)

    Shih, Chia-Chi; Chen, Yu-Jen; Wu, Sean; Tsai, Cheng-Che; Jiang, I.-Min

    2009-10-01

    This study presents an integrated device that consists of a directional coupler and an electro-optic switch. The device is designed to include a nematic liquid crystal cell, comprising a grating-like electrode. Applying the appropriate voltage to the cell yields a periodically distributed refractive index. An incident polarized beam will couple to an adjacent channel if it is parallel to the channel. The coupling efficiency is controlled by applied voltage. An obliquely injected polarized beam will be reflected and refracted in the channel, and propagated along a curved path. The route of the beam can be controlled by applying the voltage. A multiport routing was achieved for voltage modulation. In addition, the distribution of refractive index is also investigated by employing conoscopic technique experimentally and numerically.

  9. LOFT voltage insertion calibaration program

    International Nuclear Information System (INIS)

    Tillitt, D.N.; Miyasaki, F.S.

    1975-08-01

    The Loss-of-Fluid Test (LOFT) Facility is an experimental facility built around a ''scaled'' version of a large pressurized water reactor (LPWR). Part of this facility is the Data Acquisition and Visual Display System (DAVDS) as defined by the LOFT System Design Document SDD 1.4.2C. The DAVDS has a 702 data channel recording capability of which 548 are recorded digitally. The DAVDS also contains a Voltage Insertion Calibration Subsystem used to inject precise and known voltage steps into the recording systems. The computer program that controls the Voltage Insertion Calibration Subsystem is presented. 7 references. (auth)

  10. Low Voltage Power Supply Incorporating Ceramic Transformer

    CERN Document Server

    Imori, M

    2007-01-01

    A low voltage power supply provides the regulated output voltage of 1 V from the supply voltage around 48 V. The low voltage power supply incorporates a ceramic transformer which utilizes piezoelectric effect to convert voltage. The ceramic transformer isolates the secondary from the primary, thus providing the ground isolation between the supply and the output voltages. The ceramic transformer takes the place of the conventional magnetic transformer. The ceramic transformer is constructed from a ceramic bar and does not include any magnetic material. So the low voltage power supply can operate under a magnetic field. The output voltage is stabilized by feedback. A feedback loop consists of an error amplifier, a voltage controlled oscillator and a driver circuit. The amplitude ratio of the transformer has dependence on the frequency, which is utilized to stabilize the output voltage. The low voltage power supply is investigated on the analogy of the high voltage power supply similarly incorporating the cerami...

  11. E-beam high voltage switching power supply

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1997-01-01

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

  12. E-beam high voltage switching power supply

    International Nuclear Information System (INIS)

    Shimer, D.W.; Lange, A.C.

    1997-01-01

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360 degree/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs

  13. Voltage-dependent mobilization of intracellular calcium in skeletal muscle.

    Science.gov (United States)

    Schneider, M F

    1986-01-01

    In skeletal muscle calcium is released from the sarcoplasmic reticulum (SR), an internal organelle, in response to changes in the voltage across the transverse tubule (T-tubule) membrane, an external membrane system that is distinct from the SR but in close proximity to it. For T-tubule voltage changes within the physiological range, calcium release can be turned on or off on a time scale of milliseconds. The control of calcium release from the SR appears to involve at least three functional components: a voltage sensor in the T-tubule membrane, a calcium channel in the SR, and a mechanism for coupling the voltage sensor to the channel. Movement of charged or dipolar molecules within the T-tubule membrane is thought to serve as the voltage sensor. Such intramembrane charge movement (Q) can be monitored electrically and can be compared with the rate of calcium release from the SR. Calcium release is calculated from cytosolic calcium transients measured with a metallochromic indicator. Comparison of Q and the rate of release in the same isolated muscle fibre indicates that this rate is directly proportional to the amount of charge displaced in excess of a 'threshold' amount. The nature of the coupling mechanism between T-tubules and SR remains to be established but present observations impose some restrictions on possible mechanisms.

  14. A Voltage Quality Detection Method

    DEFF Research Database (Denmark)

    Chen, Zhe; Wei, Mu

    2008-01-01

    This paper presents a voltage quality detection method based on a phase-locked loop (PLL) technique. The technique can detect the voltage magnitude and phase angle of each individual phase under both normal and fault power system conditions. The proposed method has the potential to evaluate vario...... power quality disturbances, such as interruptions, sags and imbalances. Simulation studies have been performed. The effectiveness of the proposed method has been demonstrated under the simulated typical power disturbances.......This paper presents a voltage quality detection method based on a phase-locked loop (PLL) technique. The technique can detect the voltage magnitude and phase angle of each individual phase under both normal and fault power system conditions. The proposed method has the potential to evaluate various...

  15. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  16. Voltage-dependent block of charge movement components by nifedipine in frog skeletal muscle.

    Science.gov (United States)

    Huang, C L

    1990-09-01

    Potential-dependent inhibition of charge movement components by nifedipine was studied in intact, voltage-clamped, frog skeletal muscle fibers. Available charge was reduced by small shifts in holding potential (from -100 mV to -70 mV) in 2 microM nifedipine, without changes in the capacitance deduced from control (-120 mV to -100 mV) voltage steps made at a fully polarized (-100 mV) holding potential. These voltage-dependent effects did not occur in lower (0-0.5 microM) nifedipine concentrations. The voltage dependence of membrane capacitance at higher (10 microM) nifedipine concentrations was reduced even in fully polarized fibers, but shifting the holding voltage produced no further block. Voltage-dependent inhibition by nifedipine was associated with a fall in available charge, and a reduction in the charge and capacitance-voltage relationships and of late (q gamma) charging transients. It thus separated a membrane-capacitance with a distinct and steep steady-state voltage dependence. Tetracaine (2 mM) reduced voltage-dependent membrane capacitance and nonlinear charge more than did nifedipine. However, nifedipine did not exert voltage-dependent effects on charging currents, membrane capacitance, or inactivation of tetracaine-resistant (q beta) charge. This excludes participation of q beta, or the membrane charge as a whole, from the voltage-dependent effects of nifedipine. Rather, the findings suggest that the charge susceptible to potential-dependent block by nifedipine falls within the tetracaine-sensitive (q gamma) category of intramembrane charge.

  17. Reliability criteria for voltage stability

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W.; Silverstein, Brian L. [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    In face of costs pressures, there is need to allocate scare resources more effectively in order to achieve voltage stability. This naturally leads to development of probabilistic criteria and notions of rick management. In this paper it is presented a discussion about criteria for long term voltage stability limited to the case in which the time frames are topically several minutes. (author) 14 refs., 1 fig.

  18. Switched-Capacitor Voltage Multiplier

    Science.gov (United States)

    Sridharan, Govind

    1991-01-01

    Dc-to-dc power converter multiplies input supply potential by factor of nearly 40. Design does not make use of transformers or inductors but effects voltage boost-up by capacitive energy transfer. Circuit primarily made up of banks of capacitors, connected by network of integrated-circuit relays. Converter functionally linear voltage amplifier with fixed gain figure. Bipolar in operation. Output fully floating, and excellent dc isolation between input and output terminals.

  19. Effects of a low-voltage static electric field on energy metabolism in astrocytes.

    Science.gov (United States)

    Huang, R; Peng, L; Hertz, L

    1997-01-01

    Mouse astrocytes (glial cells) in primary cultures were exposed to a low-voltage static DC electric field with no current flow and thus with no generation of magnetic fields. The electric field altered the rate of glycolysis, measured by 2-deoxyglucose accumulation. The magnitude and direction of this effect depended on the polarization of the field and the applied voltage. The maximum effect was an increase of approximately 30%, which occurred with field across the cells at an intensity that can be calculated to be 0.3 mV/cm or less. Reversal of the polarization converted the stimulation to a small but statistically significant inhibition.

  20. Realistic page-turning of electronic books

    Science.gov (United States)

    Fan, Chaoran; Li, Haisheng; Bai, Yannan

    2014-01-01

    The booming electronic books (e-books), as an extension to the paper book, are popular with readers. Recently, many efforts are put into the realistic page-turning simulation o f e-book to improve its reading experience. This paper presents a new 3D page-turning simulation approach, which employs piecewise time-dependent cylindrical surfaces to describe the turning page and constructs smooth transition method between time-dependent cylinders. The page-turning animation is produced by sequentially mapping the turning page into the cylinders with different radii and positions. Compared to the previous approaches, our method is able to imitate various effects efficiently and obtains more natural animation of turning page.

  1. Macroeconomic Assessment of Voltage Sags

    Directory of Open Access Journals (Sweden)

    Sinan Küfeoğlu

    2016-12-01

    Full Text Available The electric power sector has changed dramatically since the 1980s. Electricity customers are now demanding uninterrupted and high quality service from both utilities and authorities. By becoming more and more dependent on the voltage sensitive electronic equipment, the industry sector is the one which is affected the most by voltage disturbances. Voltage sags are one of the most crucial problems for these customers. The utilities, on the other hand, conduct cost-benefit analyses before going through new investment projects. At this point, understanding the costs of voltage sags become imperative for planning purposes. The characteristics of electric power consumption and hence the susceptibility against voltage sags differ considerably among different industry subsectors. Therefore, a model that will address the estimation of worth of electric power reliability for a large number of customer groups is necessary. This paper introduces a macroeconomic model to calculate Customer Voltage Sag Costs (CVSCs for the industry sector customers. The proposed model makes use of analytical data such as value added, annual energy consumption, working hours, and average outage durations and provides a straightforward, credible, and easy to follow methodology for the estimation of CVSCs.

  2. Mechanics of the Fouetté turn.

    Science.gov (United States)

    Imura, Akiko; Yeadon, M R

    2010-12-01

    The Fouetté turn in classical ballet is performed repeatedly on one leg with swinging of the free limbs, producing a continued sequence of turns with one turn leading into the next. The purpose of this study was to determine the possible time history profiles of the twisting torque between the supporting leg and the remainder of the body that will allow continued performances of the Fouetté turn. Simulations were performed using a model which comprised the supporting leg and the remainder of the body to find torque profiles that maintain the initial angular velocity so that the state after one revolution is the same as the initial state. The solution space of torque profiles was determined for various rotation times and coefficients of friction between foot and floor. As the time for one revolution became shorter the solution space became smaller and for a given turn time there was a lower limit on the coefficient of friction. As the frictional coefficient became smaller the solution space became smaller and for a given coefficient there was a lower limit on the turn time. Turns of a given tempo can be performed on floors with different friction by modifying the twisting torque profile. When a turn is completed with a net change in angular velocity this can be compensated for in the next turn by adjusting the twisting torque profile. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Voltage-dependent block of charge movement components by nifedipine in frog skeletal muscle

    OpenAIRE

    1990-01-01

    Potential-dependent inhibition of charge movement components by nifedipine was studied in intact, voltage-clamped, frog skeletal muscle fibers. Available charge was reduced by small shifts in holding potential (from -100 mV to -70 mV) in 2 microM nifedipine, without changes in the capacitance deduced from control (-120 mV to -100 mV) voltage steps made at a fully polarized (-100 mV) holding potential. These voltage-dependent effects did not occur in lower (0-0.5 microM) nifedipine concentrati...

  4. Polarized electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Prepost, R. [Univ. of Wisconsin, Madison, WI (United States)

    1994-12-01

    The fundamentals of polarized electron sources are described with particular application to the Stanford Linear Accelerator Center. The SLAC polarized electron source is based on the principle of polarized photoemission from Gallium Arsenide. Recent developments using epitaxially grown, strained Gallium Arsenide cathodes have made it possible to obtain electron polarization significantly in excess of the conventional 50% polarization limit. The basic principles for Gallium and Arsenide polarized photoemitters are reviewed, and the extension of the basic technique to strained cathode structures is described. Results from laboratory measurements of strained photocathodes as well as operational results from the SLAC polarized source are presented.

  5. Mitigation of voltage sags in the distribution system with dynamic voltage restorer

    International Nuclear Information System (INIS)

    Viglas, D.; Belan, A.

    2012-01-01

    Dynamic voltage restorer is a custom power device that is used to improve voltage sags or swells in electrical distribution system. The components of the Dynamic Voltage Restorer consist of injection transformers, voltage source inverter, passive filters and energy storage. The main function of the Dynamic voltage restorer is used to inject three phase voltage in series and in synchronism with the grid voltages in order to compensate voltage disturbances. This article deals with mitigation of voltage sags caused by three-phase short circuit. Dynamic voltage restorer is modelled in MATLAB/Simulink. (Authors)

  6. DC High Voltage Conditioning of Photoemission Guns at Jefferson Lab FEL

    International Nuclear Information System (INIS)

    DC high voltage photoemission electron guns with GaAs photocathodes have been used to produce polarized electron beams for nuclear physics experiments for about 3 decades with great success. In the late 1990s, Jefferson Lab adopted this gun technology for a free electron laser (FEL), but to assist with high bunch charge operation, considerably higher bias voltage is required compared to the photoguns used at the Jefferson Lab Continuous Electron Beam Accelerator Facility. The FEL gun has been conditioned above 400 kV several times, albeit encountering non-trivial challenges with ceramic insulators and field emission from electrodes. Recently, high voltage processing with krypton gas was employed to process very stubborn field emitters. This work presents a summary of the high voltage techniques used to high voltage condition the Jefferson Lab FEL photoemission gun.

  7. Influence of the voltage-time derivative in X-ray emission from laboratory sparks

    Science.gov (United States)

    March, Víctor; Montanyà, Joan

    2010-10-01

    X-rays produced by laboratory sparks in air at atmospheric pressure for rod-rod and rod-plane configurations were observed. A total of 510 sparks were applied for both polarities. The paper shows the effects of the voltage rise time and the peak voltage in the generation of X-rays. It is found here that shorter rise times and high peak voltages tend to produce more X-rays emissions with higher energies than longer front waveforms or lower peak voltages. In a similar way, higher voltage variations produce more energetic emissions. This finding suggests that the variation of the electric field before the breakdown can play a fundamental role in the X-ray production. The results are similar with the observations of X-rays produced in natural lightning where detections have been associated to leader steps before the return stroke.

  8. Discharge in the saline solutions in a vicinity of the threshold voltages

    International Nuclear Information System (INIS)

    Korolev, Y D; Shemyakin, I A; Ivashov, R V; Kasyanov, V S; Landl, N V; Sun, Y H; Shao, T; Gao, Y

    2014-01-01

    This paper deals with the discharge in saline solution (0.9 % NaCl) in coaxial electrode system at voltages up to several hundred volts. The discharge was powered by bipolar pulsed generator with a pulse repetition rate of 100 kHz and by a generator of negative voltage pulses. At voltages less than a threshold value (less than 300 V)' different types of gas microcavities are formed at the surface of active electrode: the microbubble' the conglomerates of microbubbles (thin gas layers) and a macrobubble with diameter of about 1 mm and less. In a vicinity of threshold voltage the breakdown in the gas cavities occur. For negative polarity at the metal electrode the discharge burns in a form of microsparks of short duration. At positive voltage pulses' the glow-type discharge is sustained in the microcavities

  9. Voltage measuring device of a high voltage metalclad installation

    Energy Technology Data Exchange (ETDEWEB)

    Henry, J.; Girard, R.; Kieffer, J.

    1989-06-27

    The low voltage capacitor of a capacitive divider of a metalclad substation is located in a sealed compartment separated from the substation enclosure. In normal operation, the compartment is in direct communication with the enclosure via a communication orifice. The compartment can be isolated from the enclosure by closing the communication orifice valve to drain this compartment and have access to the low voltage capacitor or to the other components of the capacitive divider housed in this compartment. Any pressure or temperature difference between the compartment and the enclosure, liable to affect the measurement, is thus avoided, while authorizing access to the low voltage capacitor without having to drain the whole of the installation.

  10. Electrical Tree Initiation and Growth in Silicone Rubber under Combined DC-Pulse Voltage

    Directory of Open Access Journals (Sweden)

    Tao Han

    2018-03-01

    Full Text Available Electrical tree is a serious threat to silicone rubber (SIR insulation and can even cause breakdown. Electrical trees under alternating current (AC and direct current (DC voltage have been widely researched. While there are pulses in high-voltage direct current (HVDC cables under operating conditions caused by lightning and operating overvoltage in the power system, little research has been reported about trees under combined DC-pulse voltage. Their inception and growth mechanism is still not clear. In this paper, electrical trees are studied under several types of combined DC-pulse voltage. The initiation and growth process was recorded by a digital microscope system. The experimental results indicate that the inception pulse voltage is different under each voltage type and is influenced by the combined DC. The initial tree has two structures, determined by the pulse polarity. With increased DC prestressing time, tree inception pulse voltage with the same polarity is clearly decreased. Moreover, a special initial bubble tree was observed after the prestressing DC.

  11. Electrode voltage fall and total voltage of a transient arc

    Science.gov (United States)

    Valensi, F.; Ratovoson, L.; Razafinimanana, M.; Masquère, M.; Freton, P.; Gleizes, A.

    2016-06-01

    This paper deals with an experimental study of the components of a transient arc total voltage with duration of a few tens of ms and a current peak close to 1000 A. The cathode tip is made of graphite whereas the flat anode is made either of copper or of graphite; the electrodes gap is a few mm. The analysis of the electrical parameters is supported and validated by fast imaging and by two models: the first one is a 2D physical model of the arc allowing to calculate both the plasma temperature field and the arc voltage; the second model is able to estimate the transient heating of the graphite electrode. The main aim of the study was to detect the possible change of the cathode voltage fall (CVF) during the first instants of the arc. Indeed it is expected that during the first ms the graphite cathode is rather cool and the main mechanism of the electron emission should be the field effect emission, whereas after several tens of ms the cathode is strongly heated and thermionic emission should be predominant. We have observed some change in the apparent CVF but we have shown that this apparent change can be attributed to the variation of the solid cathode resistance. On the other hand, the possible change of CVF corresponding to the transition between a ‘cold’ and a ‘hot’ cathode should be weak and could not be characterized considering our measurement uncertainty of about 2 V. The arc column voltage (ACV) was estimated by subtracting the electrode voltage fall from the total arc voltage. The experimental transient evolution of the ACV is in very good agreement with the theoretical variation predicted by the model, showing the good ability of the model to study this kind of transient arc.

  12. A cultural turn in New Testament studies?

    African Journals Online (AJOL)

    2016-06-30

    Jun 30, 2016 ... The late twentieth century's 'linguistic turn' marked the beginning of a new consciousness in hermeneutics and even epistemology in New Testament (NT) studies.1 This turn was related to a larger spectrum of changes sometimes referred to as 'culture wars' in the human and social sciences.2 These ...

  13. performance characteristics of a cam turning attachment

    African Journals Online (AJOL)

    Dr Obe

    up of a suitable flexible shaft, a lathe spindle clutch and a shaft supported in ball bearings to carry and drive the master piece. This is shown in figure. 1. The hydraulic turning unit which is intended for cylindrical turning has been modified and used in conjunction with the drive system, as shown in figure. 2, for non cylindrical ...

  14. Towards a Practice Turn in EU Studies

    DEFF Research Database (Denmark)

    Adler-Nissen, Rebecca

    2016-01-01

    the potential of a practice turn in EU studies for both theory (overcoming dualism, replacing substantialism with processualism and rethinking power) and methods (including unstructured interviews, fieldwork and participant observation). A practice turn will force us to rethink core assumptions about the EU...

  15. Design criteria for modified Zeta rectifier with reduced voltage stress and low effect on main

    International Nuclear Information System (INIS)

    Sabzali, Ahmad J.; Ismail, Esam H.; Al-Saffar, Mustafa A.

    2008-01-01

    A single switch low harmonic rectifier based on the Zeta converter, also known as dual of single ended primary inductance converter (dual SEPIC), is presented in this paper. By adding an extra diode in series with both inductors, new discontinuous current modes (DCM) are obtained. By selecting the right DCM, it is possible to design the rectifier such that the voltage on the intermediate dc-link capacitor is less than the output DC voltage. This will result in reduced voltage stress on the main power switch, as well as zero current switching at turn on. The operating principles are confirmed with computer simulation and experimental results

  16. Voltage limitations of electrostatic accelerators

    International Nuclear Information System (INIS)

    Hyder, H. R. McK.

    1999-01-01

    The history of electrostatic accelerators has been punctuated by a series of projects in which innovative designs have failed to meet the expectations of their designers. From the early, air-insulated Van de Graaffs at Round Hill to certain of the large pressurized heavy ion accelerators of the 1970s and 1980s, increases in size or changes in design and materials have not always led to the maximum voltages expected or extrapolated. Since these failures have continued beyond childhood into a mature technology, it is reasonable to assume that the causes of voltage limitation are varied and complex. They have remained poorly understood for a number of reasons: resources for an extended program of research into breakdown and failure of electrostatic generators have always been meager, especially for large machines devoted to nuclear research; the inaccessibility of pressurized generators makes instrumentation difficult and testing slow; the calculation of transient and dynamic effects is laborious and the results difficult to verify; voltage test experiments on operating accelerators are inhibited by the significant risk of damage due to energy release on breakdown: and the total voltages (though not the local fields) achieved in many electrostatic accelerators exceed those produced in any other man-made environment. In this review, the behavior of several generators of different designs is examined in order to assess the importance of the various design features and operating conditions that control the maximum voltage achievable in a working machine

  17. Voltage limitations of electrostatic accelerators

    International Nuclear Information System (INIS)

    Hyder, H.R.

    1999-01-01

    The history of electrostatic accelerators has been punctuated by a series of projects in which innovative designs have failed to meet the expectations of their designers. From the early, air-insulated Van de Graaffs at Round Hill to certain of the large pressurized heavy ion accelerators of the 1970s and 1980s, increases in size or changes in design and materials have not always led to the maximum voltages expected or extrapolated. Since these failures have continued beyond childhood into a mature technology, it is reasonable to assume that the causes of voltage limitation are varied and complex. They have remained poorly understood for a number of reasons: resources for an extended program of research into breakdown and failure of electrostatic generators have always been meager, especially for large machines devoted to nuclear research; the inaccessibility of pressurized generators makes instrumentation difficult and testing slow; the calculation of transient and dynamic effects is laborious and the results difficult to verify; voltage test experiments on operating accelerators are inhibited by the significant risk of damage due to energy release on breakdown: and the total voltages (though not the local fields) achieved in many electrostatic accelerators exceed those produced in any other man-made environment. In this review, the behavior of several generators of different designs is examined in order to assess the importance of the various design features and operating conditions that control the maximum voltage achievable in a working machine. copyright 1999 American Institute of Physics

  18. Kantian Turning Point in Gadamer's Philosophical Hermeneutics

    Directory of Open Access Journals (Sweden)

    Kristína Bosáková

    2016-11-01

    Full Text Available The paper is treating the theme of a Kantian turning-point in the philosophical hermeneutics of H.- G. Gadamer based on of the harmonic relationship between metaphysics and science in Kantian philosophy from the point of view of the philosophical hermeneutics of Gadamer. The philosophical work of Kant had such an influence on Gadamer that without exaggerating we can talk about the Kantian turning-point in Gadamerian hermeneutics. Grondin, a former student of Gadamer, is talking about Kantian turning-point on the field of aesthetics, but in reality Kantian turning-point means much more than a mere change in the reception of the concept of judgement. It is a discovery of harmonical relationship between the beauty and the moral, between the reason and the sensitivity, between the modern sciences and the metaphysical tradition in the Kantian philosophy, made by Gadamer. This is what we call the Kantian turning-point in Gadamerian hermeneutics.

  19. KCNE3 acts by promoting voltage sensor activation in KCNQ1.

    Science.gov (United States)

    Barro-Soria, Rene; Perez, Marta E; Larsson, H Peter

    2015-12-29

    KCNE β-subunits assemble with and modulate the properties of voltage-gated K(+) channels. In the colon, stomach, and kidney, KCNE3 coassembles with the α-subunit KCNQ1 to form K(+) channels important for K(+) and Cl(-) secretion that appear to be voltage-independent. How KCNE3 subunits turn voltage-gated KCNQ1 channels into apparent voltage-independent KCNQ1/KCNE3 channels is not completely understood. Different mechanisms have been proposed to explain the effect of KCNE3 on KCNQ1 channels. Here, we use voltage clamp fluorometry to determine how KCNE3 affects the voltage sensor S4 and the gate of KCNQ1. We find that S4 moves in KCNQ1/KCNE3 channels, and that inward S4 movement closes the channel gate. However, KCNE3 shifts the voltage dependence of S4 movement to extreme hyperpolarized potentials, such that in the physiological voltage range, the channel is constitutively conducting. By separating S4 movement and gate opening, either by a mutation or PIP2 depletion, we show that KCNE3 directly affects the S4 movement in KCNQ1. Two negatively charged residues of KCNE3 (D54 and D55) are found essential for the effect of KCNE3 on KCNQ1 channels, mainly exerting their effects by an electrostatic interaction with R228 in S4. Our results suggest that KCNE3 primarily affects the voltage-sensing domain and only indirectly affects the gate.

  20. Orthogonal polynomials describing polarization aberration for rotationally symmetric optical systems.

    Science.gov (United States)

    Xu, Xiangru; Huang, Wei; Xu, Mingfei

    2015-10-19

    Optical lithography has approached a regime of high numerical aperture and wide field, where the impact of polarization aberration on imaging quality turns to be serious. Most of the existing studies focused on the distribution rule of polarization aberration on the pupil, and little attention had been paid to the field. In this paper, a new orthonormal set of polynomials is established to describe the polarization aberration of rotationally symmetric optical systems. The polynomials can simultaneously reveal the distribution rules of polarization aberration on the exit pupil and the field. Two examples are given to verify the polynomials.

  1. Ancillary service details: Voltage control

    Energy Technology Data Exchange (ETDEWEB)

    Kirby, B.; Hirst, E.

    1997-12-01

    Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

  2. METHODICAL MODEL FOR TEACHING BASIC SKI TURN

    Directory of Open Access Journals (Sweden)

    Danijela Kuna

    2013-07-01

    Full Text Available With the aim of forming an expert model of the most important operators for basic ski turn teaching in ski schools, an experiment was conducted on a sample of 20 ski experts from different countries (Croatia, Bosnia and Herzegovina and Slovenia. From the group of the most commonly used operators for teaching basic ski turn the experts picked the 6 most important: uphill turn and jumping into snowplough, basic turn with hand sideways, basic turn with clapping, ski poles in front, ski poles on neck, uphill turn with active ski guiding. Afterwards, ranking and selection of the most efficient operators was carried out. Due to the set aim of research, a Chi square test was used, as well as the differences between frequencies of chosen operators, differences between values of the most important operators and differences between experts due to their nationality. Statistically significant differences were noticed between frequencies of chosen operators (c2= 24.61; p=0.01, while differences between values of the most important operators were not obvious (c2= 1.94; p=0.91. Meanwhile, the differences between experts concerning thier nationality were only noticeable in the expert evaluation of ski poles on neck operator (c2=7.83; p=0.02. Results of current research are reflected in obtaining useful information about methodological priciples of learning basic ski turn organization in ski schools.

  3. Resilient architecture design for voltage variation

    CERN Document Server

    Reddi, Vijay Janapa

    2013-01-01

    Shrinking feature size and diminishing supply voltage are making circuits sensitive to supply voltage fluctuations within the microprocessor, caused by normal workload activity changes. If left unattended, voltage fluctuations can lead to timing violations or even transistor lifetime issues that degrade processor robustness. Mechanisms that learn to tolerate, avoid, and eliminate voltage fluctuations based on program and microarchitectural events can help steer the processor clear of danger, thus enabling tighter voltage margins that improve performance or lower power consumption. We describe

  4. Polar Heat Flow on Io

    Science.gov (United States)

    Veeder, G. J.; Matson, D. L.; Johnson, T. V.; Davies, A. G.; Blaney, D. L.

    2003-01-01

    Recently, Galileo spacecraft data have revealed Io's polar regions to be much warmer than previously expected. This unexpected development came from Photo-Polarimeter Radiometer (PPR) data which show that the minimum night temperatures are in the range of 90-95 K virtually everywhere on Io. The minimum night temperatures show no dependence upon latitude and, when away from the sunset terminator, they show no dependence upon time of night. This is indeed bizarre behavior for surface units which generally had been assumed to be passive with respect to Io's pervasive volcanism. Night temperatures of 90-95 K at high, polar latitudes are particularly hard to explain. Even assuming infinite thermal inertia, at these latitudes there is insufficient sunlight to support these warm night temperatures. Thus, through the process of elimination of other possibilities, we come to the conclusion that these surfaces are volcanically heated. Taking previously passive units and turning them into new sources of heat flow is a radical departure from previous thermophysical model paradigms. However, the geological interpretation is straight forward. We are simply seeing the effect of old, cool lava flows which cover most of the surface of Io but yet have some heat to radiate. Under these new constraints, we have taken on the challenge of formulating a physical model which quantitatively reproduces all of the observations of Io's thermal emission. In the following we introduce a new parametric model which suffices to identify a previously unrecognized polar component of Io's heat flow.

  5. Control Of Stepper Motor Movement By DC Voltage

    International Nuclear Information System (INIS)

    Gayani, Didi; Margono; Indasah, Iin; Sugito

    2000-01-01

    Instrumentation for controlling the power of reactor of TRIGA Mark II uses the stepper motor to move the control rod of neutron absorbers. The direction and speed of control rod movement are determined by the polarity and the amplitude of DC voltage as an error signal that is the difference of set point of power and the power of being measured on the control system. The unit of stepper motor controller of reactor instrumentation of TRIGA Mark II uses patent module of trade Mark of Vexta, USA. In this chance, the electronic circuit is made to function as the control of stepper motor movement by using the DC voltage to anticipate the problem may be faced in case of repair and maintenance of reactor instrumentation. As a result of experiment, it is stated that the control of motor movement by using DC voltage is performed into 2 stages. First, by making the oscillator that is proportional to the positive DC voltage. Secondly, by making the translator to translate the oscillator signal to be a logic pattern for controlling the movement of stepper motor. Translator and motor driver are made by using the L297 and L298 as a pair of stepper motor controller of SGS T HOMSON

  6. Geographical Income Polarization

    DEFF Research Database (Denmark)

    Azhar, Hussain; Jonassen, Anders Bruun

    inter municipal income inequality. Counter factual simulations show that rising property prices to a large part explain the rise in polarization. One side-effect of polarization is tendencies towards a parallel polarization of residence location patterns, where low skilled individuals tend to live......In this paper we estimate the degree, composition and development of geographical income polarization based on data at the individual and municipal level in Denmark from 1984 to 2002. Rising income polarization is reconfirmed when applying new polarization measures, the driving force being greater...

  7. 14 CFR 23.203 - Turning flight and accelerated turning stalls.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Turning flight and accelerated turning stalls. 23.203 Section 23.203 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... a 30 degree bank. Reduce speed by steadily and progressively tightening the turn with the elevator...

  8. Optically triggered high voltage switch network and method for switching a high voltage

    Energy Technology Data Exchange (ETDEWEB)

    El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

    1993-01-19

    An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

  9. Optically triggered high voltage switch network and method for switching a high voltage

    Science.gov (United States)

    El-Sharkawi, Mohamed A.; Andexler, George; Silberkleit, Lee I.

    1993-01-19

    An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

  10. Calibration Procedure for 3D Turning Dynamometer

    DEFF Research Database (Denmark)

    Axinte, Dragos Aurelian; Belluci, Walter

    1999-01-01

    The aim of the static calibration of the dynamometer is to obtain the matrix for evaluating cutting forces through the output voltage of the piezoelectric cells and charge amplifiers. In the same time, it is worth to evaluate the linearity of the dependencies between applied forces and output...... voltage and also the reproducibility of the assessed forces.The aim of this report is to present the following necessary steps in order to have a high reliable dynamometer:1. Dismounting of the dynamometer;2. Verification of the dynamometer components;3. Alignment of the piezoelectric cells;4. Preloading...

  11. On the relaxation of magnetospheric convection when Bz turns northward

    Directory of Open Access Journals (Sweden)

    M. C. Kelley

    2012-06-01

    Full Text Available The solar wind inputs considerable energy into the upper atmosphere, particularly when the interplanetary magnetic field (IMF is southward. According to Poynting's theorem (Kelley, 2009, this energy becomes stored as magnetic fields and then is dissipated by Joule heat and by energizing the plasmasheet plasma. If the IMF turns suddenly northward, very little energy is transferred into the system while Joule dissipation continues. In this process, the polar cap potential (PCP decreases. Experimentally, it was shown many years ago that the energy stored in the magnetosphere begins to decay with a time constant of two hours. Here we use Poynting's theorem to calculate this time constant and find a result that is consistent with the data.

  12. On the relaxation of magnetospheric convection when Bz turns northward

    Science.gov (United States)

    Kelley, M. C.

    2012-06-01

    The solar wind inputs considerable energy into the upper atmosphere, particularly when the interplanetary magnetic field (IMF) is southward. According to Poynting's theorem (Kelley, 2009), this energy becomes stored as magnetic fields and then is dissipated by Joule heat and by energizing the plasmasheet plasma. If the IMF turns suddenly northward, very little energy is transferred into the system while Joule dissipation continues. In this process, the polar cap potential (PCP) decreases. Experimentally, it was shown many years ago that the energy stored in the magnetosphere begins to decay with a time constant of two hours. Here we use Poynting's theorem to calculate this time constant and find a result that is consistent with the data.

  13. Congestion management considering voltage security of power systems

    International Nuclear Information System (INIS)

    Esmaili, Masoud; Shayanfar, Heidar Ali; Amjady, Nima

    2009-01-01

    Congestion in a power network is turned up due to system operating limits. To relieve congestion in a deregulated power market, the system operator pays to market participants, GENCOs and DISCOs, to alter their active powers considering their bids. After performing congestion management, the network may be operated with a low security level because of hitting some flows their upper limit and some voltages their lower limit. In this paper, a novel congestion management method based on the voltage stability margin sensitivities is introduced. Using the proposed method, the system operator so alleviates the congestion that the network can more retain its security. The proposed method not only makes the system more secure after congestion management than other methods already presented for this purpose but also its cost of providing security is lower than the earlier methods. Test results of the proposed method along with the earlier ones on the New-England test system elaborate the efficiency of the proposed method from the viewpoint of providing a better voltage stability margin and voltage profile as well as a lower security cost.

  14. Direct Evidence of Conformational Changes Associated with Voltage Gating in a Voltage Sensor Protein by Time-Resolved X-ray/Neutron Interferometry

    Science.gov (United States)

    2015-01-01

    The voltage sensor domain (VSD) of voltage-gated cation (e.g., Na+, K+) channels central to neurological signal transmission can function as a distinct module. When linked to an otherwise voltage-insensitive, ion-selective membrane pore, the VSD imparts voltage sensitivity to the channel. Proteins homologous with the VSD have recently been found to function themselves as voltage-gated proton channels or to impart voltage sensitivity to enzymes. Determining the conformational changes associated with voltage gating in the VSD itself in the absence of a pore domain thereby gains importance. We report the direct measurement of changes in the scattering-length density (SLD) profile of the VSD protein, vectorially oriented within a reconstituted phospholipid bilayer membrane, as a function of the transmembrane electric potential by time-resolved X-ray and neutron interferometry. The changes in the experimental SLD profiles for both polarizing and depolarizing potentials with respect to zero potential were found to extend over the entire length of the isolated VSD’s profile structure. The characteristics of the changes observed were in qualitative agreement with molecular dynamics simulations of a related membrane system, suggesting an initial interpretation of these changes in terms of the VSD’s atomic-level 3-D structure. PMID:24697545

  15. Reflectance Spectra of Peacock Feathers and the Turning Angles of Melanin Rods in Barbules.

    Science.gov (United States)

    Okazaki, Toshio

    2018-02-01

    I analyzed the association between the reflectance spectra and melanin rod arrangement in barbules of the eyespot of peacock feathers. The reflectance spectra from the yellow-green feather of the eyespot indicated double peaks of 430 and 540 nm. The maximum reflectance spectrum of the blue feather was 480 nm, and that of the dark blue feather was 420 nm. The reflectance spectra from brown feathers indicated double peaks of 490 and 610 nm. Transmission electron microscopic analysis confirmed that melanin rods were arranged fanwise in the outer layer toward the barbule tips. In addition, using polarized light microscope, I attempted to determine whether the turning angles of melanin rods in the barbules reflected different colors. The turning angle of the polarizing axis of the barbules was supported by that of the melanin rods, observed using transmission electron microscopic images. To compare the turning angle of melanin rods in the respective barbules, I calculated the opening width of the fanwise melanin rods by dividing the width of the barbules by the turning angle of the polarizing axis of barbules and obtained a positive correlation between the reflectance spectra and opening width of the fanwise melanin rods. Moreover, the widely spreading reflection from the barbules may occur because of the fanwise melanin rod arrangement.

  16. Voltage Weak DC Distribution Grids

    NARCIS (Netherlands)

    Hailu, T.G.; Mackay, L.J.; Ramirez Elizondo, L.M.; Ferreira, J.A.

    2017-01-01

    This paper describes the behavior of voltage weak DC distribution systems. These systems have relatively small system capacitance. The size of system capacitance, which stores energy, has a considerable effect on the value of fault currents, control complexity, and system reliability. A number of

  17. High voltage power network construction

    CERN Document Server

    Harker, Keith

    2018-01-01

    This book examines the key requirements, considerations, complexities and constraints relevant to the task of high voltage power network construction, from design, finance, contracts and project management to installation and commissioning, with the aim of providing an overview of the holistic end to end construction task in a single volume.

  18. High-Voltage Droplet Dispenser

    Science.gov (United States)

    Eichenberg, Dennis J.

    2003-01-01

    An apparatus that is extremely effective in dispensing a wide range of droplets has been developed. This droplet dispenser is unique in that it utilizes a droplet bias voltage, as well as an ionization pulse, to release a droplet. Apparatuses that deploy individual droplets have been used in many applications, including, notably, study of combustion of liquid fuels. Experiments on isolated droplets are useful in that they enable the study of droplet phenomena under well-controlled and simplified conditions. In this apparatus, a syringe dispenses a known value of liquid, which emerges from, and hangs onto, the outer end of a flat-tipped, stainless steel needle. Somewhat below the needle tip and droplet is a ring electrode. A bias high voltage, followed by a high-voltage pulse, is applied so as to attract the droplet sufficiently to pull it off the needle. The voltages are such that the droplet and needle are negatively charged and the ring electrode is positively charged.

  19. Voltage control of ferromagnetic resonance

    Directory of Open Access Journals (Sweden)

    Ziyao Zhou

    2016-06-01

    Full Text Available Voltage control of magnetism in multiferroics, where the ferromagnetism and ferroelectricity are simultaneously exhibiting, is of great importance to achieve compact, fast and energy efficient voltage controllable magnetic/microwave devices. Particularly, these devices are widely used in radar, aircraft, cell phones and satellites, where volume, response time and energy consumption is critical. Researchers realized electric field tuning of magnetic properties like magnetization, magnetic anisotropy and permeability in varied multiferroic heterostructures such as bulk, thin films and nanostructure by different magnetoelectric (ME coupling mechanism: strain/stress, interfacial charge, spin–electromagnetic (EM coupling and exchange coupling, etc. In this review, we focus on voltage control of ferromagnetic resonance (FMR in multiferroics. ME coupling-induced FMR change is critical in microwave devices, where the electric field tuning of magnetic effective anisotropic field determines the tunability of the performance of microwave devices. Experimentally, FMR measurement technique is also an important method to determine the small effective magnetic field change in small amount of magnetic material precisely due to its high sensitivity and to reveal the deep science of multiferroics, especially, voltage control of magnetism in novel mechanisms like interfacial charge, spin–EM coupling and exchange coupling.

  20. (SPWM) Voltage Source Inverter (VSI)

    African Journals Online (AJOL)

    The quest to achieve less-distorted dc-ac power conversion has resulted in the proliferation of many multilevel inverter configurations. This paper presents an experimental report of a simplified topology for single-phase, SPWM, three-level voltage source inverter wit R-L load. To keep the power circuit component count to a ...

  1. Cellular Reprogramming–Turning the Clock Back

    Indian Academy of Sciences (India)

    Cellular Reprogramming - Turning the Clock Back - Nobel Prize in Physiology or Medicine, 2012. Deepa Subramanyam ... Keywords. Embryonic stem cells; pluripotency; reprogramming; differentiation; Nobel Prize 2012. ... National Centre for Cell Science University of Pune Campus Ganeshkhind Pune 411 007, India.

  2. Turning university professors into competent learners

    NARCIS (Netherlands)

    Stefanova, Eliza; Ilieva, Miroslava; Nikolova, Nikolina; Stefanov, Krassen

    2008-01-01

    Stefanova, E., Ilieva, M., Nikolova, N, & Stefanov, K. (2008). Turning university professors into competent learners. In H. W. Sligte & R. Koper (Eds.), Proceedings of the 4th TENCompetence Open Workshop. Empowering Learners for Lifelong Competence Development: pedagogical, organisational and

  3. Page turning solutions for musicians: a survey.

    Science.gov (United States)

    Wolberg, George; Schipper, Irene

    2012-01-01

    Musicians have long been hampered by the challenge in turning sheet music while their hands are occupied playing an instrument. The sight of a human page turner assisting a pianist during a performance, for instance, is not uncommon. This need for a page turning solution is no less acute during practice sessions, which account for the vast majority of playing time. Despite widespread appreciation of the problem, there have been virtually no robust and affordable products to assist the musician. Recent progress in assistive technology and electronic reading devices offers promising solutions to this long-standing problem. The objective of this paper is to survey the technology landscape and assess the benefits and drawbacks of page turning solutions for musicians. A full range of mechanical and digital page turning products are reviewed.

  4. Conquering the Downwind Turn - SFTE Paper Followup

    National Research Council Canada - National Science Library

    Kolwey, Herman

    2000-01-01

    ...". That's 64 accidents per year to this problem, one piece of which is the turning downwind problem. It also States that: "The way human beings perceive their own movement is fairly well understood". I'm not so sure.

  5. Cellular Reprogramming–Turning the Clock Back

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 18; Issue 6. Cellular Reprogramming - Turning the Clock Back - Nobel Prize in Physiology or Medicine, 2012. Deepa Subramanyam. General Article Volume 18 Issue 6 June 2013 pp 514-521 ...

  6. Method of Rotational Turning With Multifaceted Cutters

    Science.gov (United States)

    Indakov, N.; Gordeev, Y.; Binchurov, A.

    2016-04-01

    The proposed method combines the elements of skew turning (in which a cut layer moves along the cutting edge) and rotary turning (in which the sections of the cutting edge are constantly renewed). This leads to better cooling and, hence, a longer tool life. The required cutting speed is ensured by selection of the required number of revolutions of the cutter; the rotation of the machined shaft corresponds to the rotary feed.

  7. Derrida’s Turn to Franciscan Philosophy

    Directory of Open Access Journals (Sweden)

    Marko Zlomislic

    2008-12-01

    Full Text Available Contemporary French philosophers such as Levinas, Bataille, and Derrida, along with the existentialists Kierkegaard and Nietzsche have all made use of Franciscan insights in order to safeguard the ipseity that cannot be reduced or totalized. In keeping with the taste that concerns me, this paper will examine Derrida’s turn to the poetry of Gerard Manley Hopkins and how such a turn may place Derrida within a catholic and Franciscan tradition.

  8. Polarized Light Corridor Demonstrations.

    Science.gov (United States)

    Davies, G. R.

    1990-01-01

    Eleven demonstrations of light polarization are presented. Each includes a brief description of the apparatus and the effect demonstrated. Illustrated are strain patterns, reflection, scattering, the Faraday Effect, interference, double refraction, the polarizing microscope, and optical activity. (CW)

  9. Voltage linear transformation circuit design

    Science.gov (United States)

    Sanchez, Lucas R. W.; Jin, Moon-Seob; Scott, R. Phillip; Luder, Ryan J.; Hart, Michael

    2017-09-01

    Many engineering projects require automated control of analog voltages over a specified range. We have developed a computer interface comprising custom hardware and MATLAB code to provide real-time control of a Thorlabs adaptive optics (AO) kit. The hardware interface includes an op amp cascade to linearly shift and scale a voltage range. With easy modifications, any linear transformation can be accommodated. In AO applications, the design is suitable to drive a range of different types of deformable and fast steering mirrors (FSM's). Our original motivation and application was to control an Optics in Motion (OIM) FSM which requires the customer to devise a unique interface to supply voltages to the mirror controller to set the mirror's angular deflection. The FSM is in an optical servo loop with a wave front sensor (WFS), which controls the dynamic behavior of the mirror's deflection. The code acquires wavefront data from the WFS and fits a plane, which is subsequently converted into its corresponding angular deflection. The FSM provides +/-3° optical angular deflection for a +/-10 V voltage swing. Voltages are applied to the mirror via a National Instruments digital-to-analog converter (DAC) followed by an op amp cascade circuit. This system has been integrated into our Thorlabs AO testbed which currently runs at 11 Hz, but with planned software upgrades, the system update rate is expected to improve to 500 Hz. To show that the FSM subsystem is ready for this speed, we conducted two different PID tuning runs at different step commands. Once 500 Hz is achieved, we plan to make the code and method for our interface solution freely available to the community.

  10. Voltage-gated Proton Channels

    Science.gov (United States)

    DeCoursey, Thomas E.

    2014-01-01

    Voltage-gated proton channels, HV1, have vaulted from the realm of the esoteric into the forefront of a central question facing ion channel biophysicists, namely the mechanism by which voltage-dependent gating occurs. This transformation is the result of several factors. Identification of the gene in 2006 revealed that proton channels are homologues of the voltage-sensing domain of most other voltage-gated ion channels. Unique, or at least eccentric, properties of proton channels include dimeric architecture with dual conduction pathways, perfect proton selectivity, a single-channel conductance ~103 smaller than most ion channels, voltage-dependent gating that is strongly modulated by the pH gradient, ΔpH, and potent inhibition by Zn2+ (in many species) but an absence of other potent inhibitors. The recent identification of HV1 in three unicellular marine plankton species has dramatically expanded the phylogenetic family tree. Interest in proton channels in their own right has increased as important physiological roles have been identified in many cells. Proton channels trigger the bioluminescent flash of dinoflagellates, facilitate calcification by coccolithophores, regulate pH-dependent processes in eggs and sperm during fertilization, secrete acid to control the pH of airway fluids, facilitate histamine secretion by basophils, and play a signaling role in facilitating B-cell receptor mediated responses in B lymphocytes. The most elaborate and best-established functions occur in phagocytes, where proton channels optimize the activity of NADPH oxidase, an important producer of reactive oxygen species. Proton efflux mediated by HV1 balances the charge translocated across the membrane by electrons through NADPH oxidase, minimizes changes in cytoplasmic and phagosomal pH, limits osmotic swelling of the phagosome, and provides substrate H+ for the production of H2O2 and HOCl, reactive oxygen species crucial to killing pathogens. PMID:23798303

  11. Origin of the transition voltage in gold–vacuum–gold atomic junctions

    KAUST Repository

    Wu, Kunlin

    2012-12-13

    The origin and the distance dependence of the transition voltage of gold-vacuum-gold junctions are investigated by employing first-principles quantum transport simulations. Our calculations show that atomic protrusions always exist on the electrode surface of gold-vacuum-gold junctions fabricated using the mechanically controllable break junction (MCBJ) method. The transition voltage of these gold-vacuum-gold junctions with atomically sharp electrodes is determined by the local density of states (LDOS) of the apex gold atom on the electrode surface rather than by the vacuum barrier shape. More specifically, the absolute value of the transition voltage roughly equals the rising edge of the LDOS peak contributed by the 6p atomic orbitals of the gold atoms protruding from the electrode surface, whose local Fermi level is shifted downwards when a bias voltage is applied. Since the LDOS of the apex gold atom depends strongly on the exact shape of the electrode, the transition voltage is sensitive to the variation of the atomic configuration of the junction. For asymmetric junctions, the transition voltage may also change significantly depending on the bias polarity. Considering that the occurrence of the transition voltage requires the electrode distance to be larger than a critical value, the interaction between the two electrodes is actually rather weak. Consequently, the LDOS of the apex gold atom is mainly determined by its local atomic configuration and the transition voltage only depends weakly on the electrode distance as observed in the MCBJ experiments. © 2013 IOP Publishing Ltd.

  12. Origin of the transition voltage in gold–vacuum–gold atomic junctions

    International Nuclear Information System (INIS)

    Wu Kunlin; Bai Meilin; Hou Shimin; Sanvito, Stefano

    2013-01-01

    The origin and the distance dependence of the transition voltage of gold–vacuum–gold junctions are investigated by employing first-principles quantum transport simulations. Our calculations show that atomic protrusions always exist on the electrode surface of gold–vacuum–gold junctions fabricated using the mechanically controllable break junction (MCBJ) method. The transition voltage of these gold–vacuum–gold junctions with atomically sharp electrodes is determined by the local density of states (LDOS) of the apex gold atom on the electrode surface rather than by the vacuum barrier shape. More specifically, the absolute value of the transition voltage roughly equals the rising edge of the LDOS peak contributed by the 6p atomic orbitals of the gold atoms protruding from the electrode surface, whose local Fermi level is shifted downwards when a bias voltage is applied. Since the LDOS of the apex gold atom depends strongly on the exact shape of the electrode, the transition voltage is sensitive to the variation of the atomic configuration of the junction. For asymmetric junctions, the transition voltage may also change significantly depending on the bias polarity. Considering that the occurrence of the transition voltage requires the electrode distance to be larger than a critical value, the interaction between the two electrodes is actually rather weak. Consequently, the LDOS of the apex gold atom is mainly determined by its local atomic configuration and the transition voltage only depends weakly on the electrode distance as observed in the MCBJ experiments. (paper)

  13. Approaches to Suppressing Shaft Voltage in Brushless DC Motor Driven by PWM Inverter Based on Ungrounded Common-Mode Equivalent Circuit

    Science.gov (United States)

    Maetani, Tatsuo; Isomura, Yoshinori; Watanabe, Akihiko; Iimori, Kenichi; Morimoto, Shigeo

    This paper describes an ungrounded common-mode equivalent circuit for a motor driven by a voltage-source PWM inverter. When the capacitance of the rotor was is small, the reversal of the polarities of the common-mode voltage and shaft voltage is observed. In order to model this reversal, a bridge-type equivalent circuit is proposed. On the basis of calculations and experiment, it is found the values and polarity of the shaft voltage can be are accurately determined with the proposed equivalent circuit. Furthermore, the capacitance value of the insulated rotor required to make the shaft voltage equal to or less than the dielectric breakdown voltage of the bearing grease is obtained.

  14. The essential features and modes of bacterial polar growth.

    Science.gov (United States)

    Cameron, Todd A; Zupan, John R; Zambryski, Patricia C

    2015-06-01

    Polar growth represents a surprising departure from the canonical dispersed cell growth model. However, we know relatively little of the underlying mechanisms governing polar growth or the requisite suite of factors that direct polar growth. Underscoring how classic doctrine can be turned on its head, the peptidoglycan layer of polar-growing bacteria features unusual crosslinks and in some species the quintessential cell division proteins FtsA and FtsZ are recruited to the growing poles. Remarkably, numerous medically important pathogens utilize polar growth, accentuating the need for intensive research in this area. Here we review models of polar growth in bacteria based on recent research in the Actinomycetales and Rhizobiales, with emphasis on Mycobacterium and Agrobacterium species. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Polarized Moessbauer transitions

    International Nuclear Information System (INIS)

    Barb, D.

    1975-01-01

    Theoretical aspects of the emission, absorption and scattering of polarized gamma rays are reviewed for a general case of combined magnetic and electric hyperfine interactions; various possibilities of obtaining polarized gamma sources are described and examples are given of the applications of Moessbauer spectroscopy with polarized gamma rays in solving problems of solid state physics. (A.K.)

  16. Exploring Science Through Polar Exploration

    Science.gov (United States)

    Pfirman, S. L.; Bell, R. E.; Zadoff, L.; Kelsey, R.

    2003-12-01

    Exploring the Poles is a First Year Seminar course taught at Barnard College, Columbia University. First Year Seminars are required of incoming students and are designed to encourage critical analysis in a small class setting with focused discussion. The class links historical polar exploration with current research in order to: introduce non-scientists to the value of environmental science through polar literature; discuss issues related to venturing into the unknown that are of relevance to any discipline: self-reliance, leadership, preparation, decisions under uncertainty; show students the human face of science; change attitudes about science and scientists; use data to engage students in exploring/understanding the environment and help them learn to draw conclusions from data; integrate research and education. These goals are met by bringing analysis of early exploration efforts together with a modern understanding of the polar environment. To date to class has followed the efforts of Nansen in the Fram, Scott and Amundsen in their race to the pole, and Shackleton's Endurance. As students read turn-of-the-century expedition journals, expedition progress is progressively revealed on an interactive map showing the environmental context. To bring the exploration process to life, students are assigned to expedition teams for specific years and the fates of the student "expeditions" are based on their own decisions. For example, in the Arctic, they navigate coastal sea ice and become frozen into the ice north of Siberia, re-creating Nansen's polar drift. Fates of the teams varied tremendously: some safely emerged at Fram Strait in 4 years, while others nearly became hopelessly lost in the Beaufort Gyre. Students thus learn about variability in the current polar environment through first hand experience, enabling them to appreciate the experiences, decisions, and, in some cases, the luck, of polar explorers. Evaluation by the Columbia Center for New Media, Teaching

  17. Rectifying the Current-Voltage Characteristics of a LiNbO3 Film/GaN Heterojunction

    International Nuclear Information System (INIS)

    Hao Lan-Zhong; Zhu Jun; Lei Hua-Wei; Liu Ying-Ying; Tang Zheng-Yu; Zhang Ying; Zhang Wan-Li; Li Yan-Rong; Liu Yun-Jie

    2011-01-01

    Epitaxial LiNbO 3 (LNO) films are grown on n-type GaN semiconductor substrates, forming LNO/GaN p-n junctions. The current-voltage (I—V) and capacitance-voltage (C—V) characteristics of the junctions are studied. The I—V curve shows a clear rectifying property with a turn-on voltage of 2.4 V. For the forward voltages, the conduction mechanism transits from Schottky thermionic emission for low voltages to space-charge-limited current for large voltages. Reverse C—V characteristics exhibit a linear 1/C 2 versus V plot, from which a built-in potential of 0.34 V is deduced. These results are explained using the energy-band structure of the LNO/GaN junction. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  18. Low voltage transmission electron microscopy of graphene.

    Science.gov (United States)

    Bachmatiuk, Alicja; Zhao, Jiong; Gorantla, Sandeep Madhukar; Martinez, Ignacio Guillermo Gonzalez; Wiedermann, Jerzy; Lee, Changgu; Eckert, Juergen; Rummeli, Mark Hermann

    2015-02-04

    The initial isolation of graphene in 2004 spawned massive interest in this two-dimensional pure sp(2) carbon structure due to its incredible electrical, optical, mechanical, and thermal effects. This in turn led to the rapid development of various characterization tools for graphene. Examples include Raman spectroscopy and scanning tunneling microscopy. However, the one tool with the greatest prowess for characterizing and studying graphene is the transmission electron microscope. State-of-the-art (scanning) transmission electron microscopes enable one to image graphene with atomic resolution, and also to conduct various other characterizations simultaneously. The advent of aberration correctors was timely in that it allowed transmission electron microscopes to operate with reduced acceleration voltages, so that damage to graphene is avoided while still providing atomic resolution. In this comprehensive review, a brief introduction is provided to the technical aspects of transmission electron microscopes relevant to graphene. The reader is then introduced to different specimen preparation techniques for graphene. The different characterization approaches in both transmission electron microscopy and scanning transmission electron microscopy are then discussed, along with the different aspects of electron diffraction and electron energy loss spectroscopy. The use of graphene for other electron microscopy approaches such as in-situ investigations is also presented. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Polarization imaging apparatus with auto-calibration

    Science.gov (United States)

    Zou, Yingyin Kevin; Zhao, Hongzhi; Chen, Qiushui

    2013-08-20

    A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5.degree., a second variable phase retarder with its optical axis aligned 45.degree., a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I.sub.0, I.sub.1, I.sub.2 and I.sub.3 of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (.pi.,0), (.pi.,.pi.) and (.pi./2,.pi.), respectively. Then four Stokes components of a Stokes image, S.sub.0, S.sub.1, S.sub.2 and S.sub.3 were calculated using the four intensity images.

  20. Polarization Imaging Apparatus with Auto-Calibration

    Science.gov (United States)

    Zou, Yingyin Kevin (Inventor); Zhao, Hongzhi (Inventor); Chen, Qiushui (Inventor)

    2013-01-01

    A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5 deg, a second variable phase retarder with its optical axis aligned 45 deg, a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I(sub 0), I(sub 1), I(sub 2) and I(sub 3) of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (pi,0), (pi,pi) and (pi/2,pi), respectively. Then four Stokes components of a Stokes image, S(sub 0), S(sub 1), S(sub 2) and S(sub 3) were calculated using the four intensity images.

  1. Over-voltage protection system and method

    Science.gov (United States)

    Chi, Song; Dong, Dong; Lai, Rixin

    2017-05-02

    An over-voltage protection system includes an electronic valve connected across two terminals of a circuit and an over-voltage detection circuit connected across one of the plurality of semiconductor devices for detecting an over-voltage across the circuit. The electronic valve includes a plurality of semiconductor devices connected in series. The over-voltage detection circuit includes a voltage divider circuit connected to a break-over diode in a way to provide a representative low voltage to the break-over diode and an optocoupler configured to receive a current from the break-over diode when the representative low voltage exceeds a threshold voltage of the break-over diode indicating an over-voltage condition. The representative low voltage provided to the break-over diode represents a voltage across the one semiconductor device. A plurality of self-powered gate drive circuits are connected to the plurality of semiconductor devices, wherein the plurality of self-powered gate drive circuits receive over-voltage triggering pulses from the optocoupler during the over-voltage condition and switch on the plurality of semiconductor devices to bypass the circuit.

  2. Bodily-visual practices and turn continuation.

    Science.gov (United States)

    Ford, Cecilia E; Thompson, Sandra A; Drake, Veronika

    2012-01-01

    This paper considers points in turn construction where conversation researchers have shown that talk routinely continues beyond possible turn completion, but where we find bodily-visual behavior doing such turn extension work. The bodily-visual behaviors we examine share many features with verbal turn extensions, but we argue that embodied movements have distinct properties that make them well-suited for specific kinds of social action, including stance display and by-play in sequences framed as subsidiary to a simultaneous and related verbal exchange. Our study is in line with a research agenda taking seriously the point made by Goodwin (2000a, b, 2003), Hayashi (2003, 2005), Iwasaki (2009), and others that scholars seeking to account for practices in language and social interaction do themselves a disservice if they privilege the verbal dimension; rather, as suggested in Stivers/Sidnell (2005), each semiotic system/modality, while coordinated with others, has its own organization. With the current exploration of bodily-visual turn extensions, we hope to contribute to a growing understanding of how these different modes of organization are managed concurrently and in concert by interactants in carrying out their everyday social actions.

  3. The Physics of Polarization

    Science.gov (United States)

    Landi Degl'Innocenti, Egidio

    2015-10-01

    The introductory lecture that has been delivered at this Symposium is a condensed version of an extended course held by the author at the XII Canary Island Winter School from November 13 to November 21, 2000. The full series of lectures can be found in Landi Degl'Innocenti (2002). The original reference is organized in 20 Sections that are here itemized: 1. Introduction, 2. Description of polarized radiation, 3. Polarization and optical devices: Jones calculus and Muller matrices, 4. The Fresnel equations, 5. Dichroism and anomalous dispersion, 6. Polarization in everyday life, 7. Polarization due to radiating charges, 8. The linear antenna, 9. Thomson scattering, 10. Rayleigh scattering, 11. A digression on Mie scattering, 12. Bremsstrahlung radiation, 13. Cyclotron radiation, 14. Synchrotron radiation, 15. Polarization in spectral lines, 16. Density matrix and atomic polarization, 17. Radiative transfer and statistical equilibrium equations, 18. The amplification condition in polarized radiative transfer, and 19. Coupling radiative transfer and statistical equilibrium equations.

  4. Analyzing randomly occurring voltage breakdowns

    International Nuclear Information System (INIS)

    Wiltshire, C.W.

    1977-01-01

    During acceptance testing of high-vacuum neutron tubes, 40% of the tubes failed after experiencing high-voltage breakdowns during the aging process. Use of a digitizer in place of an oscilloscope revealed two types of breakdowns, only one of which affected acceptance testing. This information allowed redesign of the aging sequence to prevent tube damage and improve yield and quality of the final product

  5. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  6. Advances in high voltage engineering

    CERN Document Server

    Haddad, A

    2005-01-01

    This book addresses the very latest research and development issues in high voltage technology and is intended as a reference source for researchers and students in the field, specifically covering developments throughout the past decade. This unique blend of expert authors and comprehensive subject coverage means that this book is ideally suited as a reference source for engineers and academics in the field for years to come.

  7. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  8. Thermoelectric spin voltage in graphene.

    Science.gov (United States)

    Sierra, Juan F; Neumann, Ingmar; Cuppens, Jo; Raes, Bart; Costache, Marius V; Valenzuela, Sergio O

    2018-02-01

    In recent years, new spin-dependent thermal effects have been discovered in ferromagnets, stimulating a growing interest in spin caloritronics, a field that exploits the interaction between spin and heat currents 1,2 . Amongst the most intriguing phenomena is the spin Seebeck effect 3-5 , in which a thermal gradient gives rise to spin currents that are detected through the inverse spin Hall effect 6-8 . Non-magnetic materials such as graphene are also relevant for spin caloritronics, thanks to efficient spin transport 9-11 , energy-dependent carrier mobility and unique density of states 12,13 . Here, we propose and demonstrate that a carrier thermal gradient in a graphene lateral spin valve can lead to a large increase of the spin voltage near to the graphene charge neutrality point. Such an increase results from a thermoelectric spin voltage, which is analogous to the voltage in a thermocouple and that can be enhanced by the presence of hot carriers generated by an applied current 14-17 . These results could prove crucial to drive graphene spintronic devices and, in particular, to sustain pure spin signals with thermal gradients and to tune the remote spin accumulation by varying the spin-injection bias.

  9. Low voltage electron beam accelerators

    International Nuclear Information System (INIS)

    Ochi, Masafumi

    2003-01-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  10. Polarization preserving ultra fast optical shutter for quantum information processing

    OpenAIRE

    Spagnolo, Nicolo'; Vitelli, Chiara; Giacomini, Sandro; Sciarrino, Fabio; De Martini, Francesco

    2008-01-01

    We present the realization of a ultra fast shutter for optical fields, which allows to preserve a generic polarization state, based on a self-stabilized interferometer. It exhibits high (or low) transmittivity when turned on (or inactive), while the fidelity of the polarization state is high. The shutter is realized through two beam displacing prisms and a longitudinal Pockels cell. This can represent a useful tool for controlling light-atom interfaces in quantum information processing.

  11. Method to minimize the low-frequency neutral-point voltage oscillations with time-offset injection for neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, Kyo-Beum; Blaabjerg, Frede

    2013-01-01

    This paper proposes a method to reduce the low-frequency neutral-point voltage oscillations. The neutral-point voltage oscillations are considerably reduced by adding a time-offset to the three phase turn-on times. The proper time-offset is simply calculated considering the phase currents and dwe...... of the proposed strategy....

  12. Spin-torque diode radio-frequency detector with voltage tuned resonance

    Energy Technology Data Exchange (ETDEWEB)

    Skowroński, Witold, E-mail: skowron@agh.edu.pl; Frankowski, Marek; Stobiecki, Tomasz [AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Wrona, Jerzy [AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Singulus Technologies, Kahl am Main 63796 (Germany); Ogrodnik, Piotr [Faculty of Physics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warsaw (Poland); AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Barnaś, Józef [Faculty of Physics, Adam Mickiewicz University, ul. Umultowska 85, 61-614 Poznań (Poland); Institute of Molecular Physics, Polish Academy of Sciences, Smoluchowskiego 17, 60-179 Poznań (Poland)

    2014-08-18

    We report on a voltage-tunable radio-frequency (RF) detector based on a magnetic tunnel junction (MTJ). The spin-torque diode effect is used to excite and/or detect RF oscillations in the magnetic free layer of the MTJ. In order to reduce the overall in-plane magnetic anisotropy of the free layer, we take advantage of the perpendicular magnetic anisotropy at the interface between ferromagnetic and insulating layers. The applied bias voltage is shown to have a significant influence on the magnetic anisotropy, and thus on the resonance frequency of the device. This influence also depends on the voltage polarity. The obtained results are accounted for in terms of the interplay of spin-transfer-torque and voltage-controlled magnetic anisotropy effects.

  13. Turning points in the history of mathematics

    CERN Document Server

    Grant, Hardy

    2015-01-01

    This book explores some of the major turning points in the history of mathematics, ranging from ancient Greece to the present, demonstrating the drama that has often been a part of its evolution. Studying these breakthroughs, transitions, and revolutions, their stumbling-blocks and their triumphs, can help illuminate the importance of the history of mathematics for its teaching, learning, and appreciation. Some of the turning points considered are the rise of the axiomatic method (most famously in Euclid), and the subsequent major changes in it (for example, by David Hilbert); the “wedding,” via analytic geometry, of algebra and geometry; the “taming” of the infinitely small and the infinitely large; the passages from algebra to algebras, from geometry to geometries, and from arithmetic to arithmetics; and the revolutions in the late nineteenth and early twentieth centuries that resulted from Georg Cantor’s creation of transfinite set theory. The origin of each turning point is discussed, along with...

  14. First turn around strategy for RHIC

    International Nuclear Information System (INIS)

    Milutinovic, J.; Ruggiero, A.G.

    1991-01-01

    The authors present a strategy for achieving the so-called first turn around in RHIC. The strategy is based on the same method proposed to correct a distorted closed orbit in RHIC, i.e. on a generalization of the local three-bump method. They found out that the method is very effective in passing the beam through a non-ideal, insufficiently known, machine. The perturbed lattice was generated by the code PATRIS, which was also adapted to control the newly developed software. In ten distributions of errors the software was capable of passing the beam through in 2-3 injection attempts, at full sextupole strength. It was also determined that once the beam makes the first turn around and all the correctors are energized, it stays in the machine for at least several hundred turns

  15. Adiabatic Siberian snake turn-on and acceleration through depolarizing resonances

    International Nuclear Information System (INIS)

    Koulsha, A.V.; Anferov, V.A.; Baiod, R.

    1993-01-01

    The authors plan to install in the IUCF Cooler Ring a rampable partial (30%) Siberian snake to test if the spin polarization is preserved during adiabatic turn-on. They also plan to use this ramped snake to accelerate polarized protons to 370 MeV while passing through two depolarizing resonances. The Siberian snake will consist of two small rampable warm solenoids placed symmetrically on either side of the exciting cold 2 T·m solenoid which would run dc at about 0.5 T·m. Ramping each warm magnet from about -0.25T·m to + 0.25 T·m. Recent experiments showed that turning on the snake in 100 msec at 370 MeV causes no serious beam loss

  16. CONNECTION OF TURN AHEAD AND TURN BACK WITH MOTORIC ABILITIES OF THE FIFTH GRADE STUDENTS

    Directory of Open Access Journals (Sweden)

    Jovica Petković

    2006-06-01

    Full Text Available The research is done for the purpose of determination and defining of the level of connection between some motoric abilities with success in realization of programmed contents from the area of gymnastics (turn ahead and turn back. The research is done on the sample of fifty one students from the fifth grade of Elementary School, on ten motoric tests and on two specific motoric assignments – turn ahead and turn back. The results of this research clearly point that there exist the multitude of statistically important coefficients of correlation between treated motoric abilities and applied motoric assignments.

  17. Bootstrapped Low-Voltage Analog Switches

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    1999-01-01

    Novel low-voltage constant-impedance analog switch circuits are proposed. The switch element is a single MOSFET, and constant-impedance operation is obtained using simple circuits to adjust the gate and bulk voltages relative to the switched signal. Low-voltage (1-volt) operation is made feasible...

  18. Voltage Quality of Grid Connected Wind Turbines

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Sun, Tao

    2004-01-01

    Grid connected wind turbines may cause quality problems, such as voltage variation and flicker. This paper discusses the voltage variation and flicker emission of grid connected wind turbines with doubly-fed induction generators. A method to compensate flicker by using a voltage source converter...

  19. 30 CFR 18.47 - Voltage limitation.

    Science.gov (United States)

    2010-07-01

    ... MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements... particular voltage(s) are provided in the design and construction of the equipment, its wiring, and... exceed 25 amperes. (3) All high voltage switch gear and control for equipment having a nameplate rating...

  20. Voltage generators of high voltage high power accelerators

    International Nuclear Information System (INIS)

    Svinin, M.P.

    1981-01-01

    High voltage electron accelerators are widely used in modern radiation installations for industrial purposes. In the near future further increasing of their power may be effected, which enables to raise the efficiency of the radiation processes known and to master new power-consuming production in industry. Improvement of HV generators by increasing their power and efficiency is one of many scientific and engineering aspects the successful solution of which provides further development of these accelerators and their technical parameters. The subject is discussed in detail. (author)

  1. Seismic interferometry-turning noise into signal

    NARCIS (Netherlands)

    Curtis, A.; Gerstoft, P.; Sato, H.; Snieder, R.; Wapenaar, C.P.A.

    2006-01-01

    Turning noise into useful data—every geophysicist's dream? And now it seems possible. The field of seismic interferometry has at its foundation a shift in the way we think about the parts of the signal that are currently filtered out of most analyses—complicated seismic codas (the multiply scattered

  2. Business Intelligence: Turning Knowledge into Power

    Science.gov (United States)

    Endsley, Krista

    2009-01-01

    Today, many school districts are turning to business intelligence tools to retrieve, organize, and share knowledge for faster analysis and more effective, guided decision making. Business intelligence (BI) tools are the technologies and applications that gather and report information to help an organization's leaders make better decisions. BI…

  3. Speed docking: reducing truck turn times

    NARCIS (Netherlands)

    Ploos van Amstel, W.

    2013-01-01

    Truck turn times in FMCG supply chain are unreliable. The Dutch ‘Speed Docking’ project in gave clear evidence to this. The result is too many trucks and drivers. FMCG producers, together with logistics service providers and customers, can realise improvements with the use of mobile communication,

  4. The dynamic turn in quantum logic

    NARCIS (Netherlands)

    Baltag, Alexandru; Smets, Sonja

    In this paper we show how ideas coming from two areas of research in logic can reinforce each other. The first such line of inquiry concerns the "dynamic turn" in logic and especially the formalisms inspired by Propositional Dynamic Logic (PDL); while the second line concerns research into the

  5. Strategy in Generative Planning of Turning Processes

    NARCIS (Netherlands)

    van Houten, Frederikus J.A.M.; Kals, H.J.J.

    1986-01-01

    This paper reports on the process and operations planning system ROUND and the strategies which underlie the decision making processes in the planning of turning operations. At first, an outline is given about the environment for which generative systems like ROUND are being developed. The

  6. Train turn restrictions and line plan performance

    DEFF Research Database (Denmark)

    Burggraeve, Sofie; Bull, Simon Henry; Lusby, Richard Martin

    In this paper we study the impact of the `turn conditions' in end stations on the performance of a line plan. If trains have to turn on their platform in an end station, the yoccupy the platform for several minutes. A more preferred option, from a timetabling point of view, would be that a train...... disappears from the platform in its end station after dwelling and only appears again when departing for a subsequent trip. In this case, the train will not interfere with other trains that dwell on the platform during the time between these events. However, this option is only possible if the train can stay...... in a exible and large enough shunt. Starting from a given line plan, we compare two timetables, one where trains have to turn on their platform and one where trains can turn in a shunt. We evaluate the impact on the performance of the line plan by its feasibility for timetabling,the minimum overall buffer...

  7. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    DEFF Research Database (Denmark)

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis...

  8. Multiloop Rapid-Rise/Rapid Fall High-Voltage Power Supply

    Science.gov (United States)

    Bearden, Douglas

    2007-01-01

    A proposed multiloop power supply would generate a potential as high as 1.25 kV with rise and fall times power supply would, moreover, be programmable to generate output potentials from 20 to 1,250 V and would be capable of supplying a current of at least 300 A at 1,250 V. This power supply is intended to be a means of electronic shuttering of a microchannel plate that would be used to intensify the output of a charge-coupled-device imager to obtain exposure times as short as 1 ms. The basic design of this power supply could also be adapted to other applications in which high voltages and high slew rates are needed. At the time of reporting the information for this article, there was no commercially available power supply capable of satisfying the stated combination of voltage, rise-time, and fall-time requirements. The power supply would include a preregulator that would be used to program a voltage 1/30 of the desired output voltage. By means of a circuit that would include a pulse-width modulator (PWM), two voltage doublers, and a transformer having two primary and two secondary windings, the preregulator output voltage would be amplified by a factor of 30. A resistor would limit the current by controlling a drive voltage applied to field-effect transistors (FETs) during turn-on of the PWM. Two feedback loops would be used to regulate the high output voltage. A pulse transformer would be used to turn on four FETs to short-circuit output capacitors when the outputs of the PWM were disabled. Application of a 0-to-5-V square to a PWM shut-down pin would cause a 20-to-1,250-V square wave to appear at the output.

  9. Polarized particle levitation in hexapole field

    International Nuclear Information System (INIS)

    Jones, T.B.; Kallio, G.A.; Robinson, K.S.

    1976-06-01

    Proposed here is a novel electrostatic levitation scheme which uses the force exerted by a non-uniform electric field on a polarized particle. The scheme differs from conventional quadrupole levitation devices principally in that the levitated particle is uncharged. In order to provide the proper force required to achieve dynamic stabilization, a very intense non-uniform time-varying electric field produced by a three-dimensional hexapole electrode structure is utilized. The primary advantage of this levitation scheme might accrue in target fabrication operations where particle charge is undesirable or where reproducible charging of the particles themselves is difficult, due to high resistivity. The disadvantages of this scheme, as compared to charged particle levitation, are (i) a more complex electrode structure and (ii) significantly higher voltages. The scheme has possible application to molecular mass spectrometry, in situations where un-ionized but strongly polar or polarizable molecules are to be trapped or confined for analysis

  10. [Review] Polarization and Polarimetry

    Science.gov (United States)

    Trippe, Sascha

    2014-02-01

    Polarization is a basic property of light and is fundamentally linked to the internal geometry of a source of radiation. Polarimetry complements photometric, spectroscopic, and imaging analyses of sources of radiation and has made possible multiple astrophysical discoveries. In this article I review (i) the physical basics of polarization: electromagnetic waves, photons, and parameterizations; (ii) astrophysical sources of polarization: scattering, synchrotron radiation, active media, and the Zeeman, Goldreich-Kylafis, and Hanle effects, as well as interactions between polarization and matter (like birefringence, Faraday rotation, or the Chandrasekhar-Fermi effect); (iii) observational methodology: on-sky geometry, influence of atmosphere and instrumental polarization, polarization statistics, and observational techniques for radio, optical, and X/γ wavelengths; and (iv) science cases for astronomical polarimetry: solar and stellar physics, planetary system bodies, interstellar matter, astrobiology, astronomical masers, pulsars, galactic magnetic fields, gamma-ray bursts, active galactic nuclei, and cosmic microwave background radiation.

  11. Motor power factor controller with a reduced voltage starter

    Science.gov (United States)

    Nola, Frank J. (Inventor)

    1983-01-01

    A power factor type motor controller in which the conventional power factor constant voltage command signal is replaced during a starting interval with a graduated control voltage. The present invention adds to the three-phase system of pending application Ser. No. 199,765, filed Oct. 23, 1980, means for modifying the operation of the system for a motor start-up interval of 5 to 30 seconds. The modification is that of providing via ramp generator 174 an initial ramp-like signal which replaces a constant power factor signal supplied by potentiometer 70. The ramp-like signal is applied to terminal 40 where it is summed with an operating power factor signal from phase detectors 32, 34, and 36 to thereby obtain a control signal for ultimately controlling SCR devices 12, 14, and 16 to effect a gradual turn-on of motor 10. The significant difference of the present invention over prior art is that the SCR devices are turned on at an advancing rate with time responsive to the combination signal described rather than simply a function of a ramp-like signal alone. The added signal, the operating power factor signal, enables the production of a control signal which effectively eliminates a prior problem with many motor starting circuits, which is that of accompanying motor instabilities.

  12. High voltage engineering. Fundamentals. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Kuffel, E. (ed.) [University of Manitoba, Winnipeg (Canada); Zaengl, W.S. (ed.) [Swiss Federal Institute of Technology, Zuric (Switzerland). Electrical Engineering Dept.; Kuffel, J. (ed.) [Ontario Hydro Technologies, Toronto (Canada)

    2000-07-01

    The basics of high voltage laboratory techniques and phenomena, together with the principles governing the design of high voltage insulation, are covered in this book for students studying high voltage engineering at both undergraduate and postgraduate level, utility engineers, designers and operators of high voltage equipment. In this new edition, the text has been entirely revised to reflect current practice. Major changes include coverage of the latest instrumentation, the use of electronegative gases such as sulphur hexafluoride, modern diagnostic techniques, and high voltage testing procedures with statistical approaches. (author)

  13. -and -turns in proteins revisited: A new set of amino acid turn ...

    Indian Academy of Sciences (India)

    -turns (7153) and -turns (911) extracted from these proteins were used to derive a revised set of type-dependent amino acid positional preferences and potentials. Compared with previous results, the preference for proline, methionine and tryptophan has increased and the preference for glutamine, valine, glutamic acid ...

  14. Research of remote control system in turn by turn timing system

    International Nuclear Information System (INIS)

    Zhan Zhifeng; Xiao Yanguo; Ma Kui; Yin Zejie; Wu Xiaoyi

    2003-01-01

    In this paper, we introduce a remote control system which is used in a frequency dividing and time-delay module. This control system is based on client/server architecture, and RS232 serial communication protocol. This control system is used in timing system of NSRL turn by turn beam position monitor

  15. Inductive voltage adder advanced hydrodynamic radiographic technology demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Mazarakis, M.G.; Poukey, J.W.; Maenchen; Rovang, D.C. [and others

    1997-04-01

    This paper presents the design, results, and analysis of a high-brightness electron beam technology demonstration experiment completed at Sandia National Laboratories, performed in collaboration with Los Alamos National Laboratory. The anticipated electron beam parameters were: 12 MeV, 35-40 kA, 0.5-mm rms radius, and 40-ns full width half maximum (FWHM) pulse duration. This beam, on an optimum thickness tantalum converter, should produce a very intense x-ray source of {approximately} 1.5-mm spot size and 1 kR dose @ 1 m. The accelerator utilized was SABRE, a pulsed inductive voltage adder, and the electron source was a magnetically immersed foilless electron diode. For these experiments, SABRE was modified to high-impedance negative-polarity operation. A new 100-ohm magnetically insulated transmission line cathode electrode was designed and constructed; the cavities were rotated 180{degrees} poloidally to invert the central electrode polarity to negative; and only one of the two pulse forming lines per cavity was energized. A twenty- to thirty-Tesla solenoidal magnet insulated the diode and contained the beam at its extremely small size. These experiments were designed to demonstrate high electron currents in submillimeter radius beams resulting in a high-brightness high-intensity flash x-ray source for high-resolution thick-object hydrodynamic radiography. The SABRE facility high-impedance performance was less than what was hoped. The modifications resulted in a lower amplitude (9 MV), narrower-than-anticipated triangular voltage pulse, which limited the dose to {approximately} 20% of the expected value. In addition, halo and ion-hose instabilities increased the electron beam spot size to > 1.5 mm. Subsequent, more detailed calculations explain these reduced output parameters. An accelerator designed (versus retrofit) for this purpose would provide the desired voltage and pulse shape.

  16. Capacitor Voltages Measurement and Balancing in Flying Capacitor Multilevel Converters Utilizing a Single Voltage Sensor

    DEFF Research Database (Denmark)

    Farivar, Glen; Ghias, Amer M. Y. M.; Hredzak, Branislav

    2017-01-01

    This paper proposes a new method for measuring capacitor voltages in multilevel flying capacitor (FC) converters that requires only one voltage sensor per phase leg. Multiple dc voltage sensors traditionally used to measure the capacitor voltages are replaced with a single voltage sensor at the ac...... side of the phase leg. The proposed method is subsequently used to balance the capacitor voltages using only the measured ac voltage. The operation of the proposed measurement and balancing method is independent of the number of the converter levels. Experimental results presented for a five-level FC...

  17. A dynamic voltage restorer (DVR) with selective harmonic compensation at medium voltage level

    DEFF Research Database (Denmark)

    Newman, M.J.; Holmes, D.G.; Nielsen, J.G.

    2005-01-01

    Dynamic voltage restorers (DVRs) are now becoming more established in industry to reduce the impact of voltage sags to sensitive loads. However, DVRs spend most of their time in standby mode, since voltage sags occur very infrequently, and hence their utilization is low. In principle, it would...... voltage harmonic compensation capabilities with minimal effect on the sag compensation performance of the basic DVR. The proposed controller has been experimentally verified on a medium-voltage (10 kV) three-phase DVR prototype under a range of conditions, including distorted supply voltages, nonlinear...... loads, and operation during distorted voltage sags....

  18. Control and Testing of a Dynamic Voltage Restorer (DVR) at Medium Voltage Level

    DEFF Research Database (Denmark)

    Nielsen, John Godsk; Newman, Michael; Nielsen, Hans Ove

    2004-01-01

    power sensitive loads from voltage sags. This paper reports practical test results obtained on a medium voltage (10 kV) level using a DVR at a Distribution test facility in Kyndby, Denmark. The DVR was designed to protect a 400-kVA load from a 0.5-p.u. maximum voltage sag. The reported DVR verifies......The dynamic voltage restorer (DVR) has become popular as a cost effective solution for the protection of sensitive loads from voltage sags. Implementations of the DVR have been proposed at both a low voltage (LV) level, as well as a medium voltage (MV) level; and give an opportunity to protect high...

  19. Polarization feedback laser stabilization

    Science.gov (United States)

    Esherick, P.; Owyoung, A.

    1987-09-28

    A system for locking two Nd:YAG laser oscillators includes an optical path for feeding the output of one laser into the other with different polarizations. Elliptical polarization is incorporated into the optical path so that the change in polarization that occurs when the frequencies coincide may be detected to provide a feedback signal to control one laser relative to the other. 4 figs.

  20. Polarization in Sagittarius A*

    OpenAIRE

    Bower, Geoffrey C.

    2000-01-01

    We summarize the current state of polarization observations of Sagittarius A*, the compact radio source and supermassive black hole candidate in the Galactic Center. These observations are providing new tools for understanding accretion disks, jets and their environments. Linear polarization observations have shown that Sgr A* is unpolarized at frequencies as high as 86 GHz. However, recent single-dish observations indicate that Sgr A* may have strong linear polarization at frequencies higher...

  1. Cometary dust dynamics and polarization in electromagnetic radiation fields

    Science.gov (United States)

    Herranen, J.; Markkanen, J.; Muinonen, K.

    2017-09-01

    In our work, we apply a fast solution of electromagnetic scattering to determine the induced spin and movement of a dust particle in a cometary coma. The resulted aligned spinning state is then used to determine the observable polarization of the dust, and compared against the randomly averaged polarization of the same particle. We find that measurable effects arise due to the alignment. In the future, similar methods can be used to model the dynamics and in turn the polarization of the whole coma.

  2. A mini-photofragment translational spectrometer with ion velocity map imaging using low voltage acceleration

    Science.gov (United States)

    Qi, Wenke; Jiang, Pan; Lin, Dan; Chi, Xiaoping; Cheng, Min; Du, Yikui; Zhu, Qihe

    2018-01-01

    A mini time-sliced ion velocity map imaging photofragment translational spectrometer using low voltage acceleration has been constructed. The innovation of this apparatus adopts a relative low voltage (30-150 V) to substitute the traditional high voltage (650-4000 V) to accelerate and focus the fragment ions. The overall length of the flight path is merely 12 cm. There are many advantages for this instrument, such as compact structure, less interference, and easy to operate and control. Low voltage acceleration gives a longer turn-around time to the photofragment ions forming a thicker Newton sphere, which provides sufficient time for slicing. Ion trajectory simulation has been performed for determining the structure dimensions and the operating voltages. The photodissociation and multiphoton ionization of O2 at 224.999 nm is used to calibrate the ion images and examine the overall performance of the new spectrometer. The velocity resolution (Δν/ν) of this spectrometer from O2 photodissociation is about 0.8%, which is better than most previous results using high acceleration voltage. For the case of CF3I dissociation at 277.38 nm, many CF3 vibrational states have been resolved, and the anisotropy parameter has been measured. The application of low voltage acceleration has shown its advantages on the ion velocity map imaging (VMI) apparatus. The miniaturization of the VMI instruments can be realized on the premise of high resolution.

  3. A mini-photofragment translational spectrometer with ion velocity map imaging using low voltage acceleration.

    Science.gov (United States)

    Qi, Wenke; Jiang, Pan; Lin, Dan; Chi, Xiaoping; Cheng, Min; Du, Yikui; Zhu, Qihe

    2018-01-01

    A mini time-sliced ion velocity map imaging photofragment translational spectrometer using low voltage acceleration has been constructed. The innovation of this apparatus adopts a relative low voltage (30-150 V) to substitute the traditional high voltage (650-4000 V) to accelerate and focus the fragment ions. The overall length of the flight path is merely 12 cm. There are many advantages for this instrument, such as compact structure, less interference, and easy to operate and control. Low voltage acceleration gives a longer turn-around time to the photofragment ions forming a thicker Newton sphere, which provides sufficient time for slicing. Ion trajectory simulation has been performed for determining the structure dimensions and the operating voltages. The photodissociation and multiphoton ionization of O 2 at 224.999 nm is used to calibrate the ion images and examine the overall performance of the new spectrometer. The velocity resolution (Δν/ν) of this spectrometer from O 2 photodissociation is about 0.8%, which is better than most previous results using high acceleration voltage. For the case of CF 3 I dissociation at 277.38 nm, many CF 3 vibrational states have been resolved, and the anisotropy parameter has been measured. The application of low voltage acceleration has shown its advantages on the ion velocity map imaging (VMI) apparatus. The miniaturization of the VMI instruments can be realized on the premise of high resolution.

  4. Airborne Laser Polarization Sensor

    Science.gov (United States)

    Kalshoven, James, Jr.; Dabney, Philip

    1991-01-01

    Instrument measures polarization characteristics of Earth at three wavelengths. Airborne Laser Polarization Sensor (ALPS) measures optical polarization characteristics of land surface. Designed to be flown at altitudes of approximately 300 m to minimize any polarizing or depolarizing effects of intervening atmosphere and to look along nadir to minimize any effects depending on look angle. Data from measurements used in conjunction with data from ground surveys and aircraft-mounted video recorders to refine mathematical models used in interpretation of higher-altitude polarimetric measurements of reflected sunlight.

  5. Polarization at SLC

    International Nuclear Information System (INIS)

    Swartz, M.L.

    1988-07-01

    The SLAC Linear Collider has been designed to readily accommodate polarized electron beams. Considerable effort has been made to implement a polarized source, a spin rotation system, and a system to monitor the beam polarization. Nearly all major components have been fabricated. At the current time, several source and polarimeter components have been installed. The installation and commissioning of the entire system will take place during available machine shutdown periods as the commissioning of SLC progresses. It is expected that a beam polarization of 45% will be achieved with no loss in luminosity. 13 refs., 15 figs

  6. Assessment of Voltage Stability Using Network Equivalent

    Directory of Open Access Journals (Sweden)

    Abhijit Chakrabarti

    2011-12-01

    Full Text Available In this paper a fast system voltage stability index (FSVSI has been proposed to assess overall system voltage stability of a multi-bus power system at a particular operating point using the concept of two bus network equivalent. A universal direct voltage stability index has also been explored to assess local (DVSI as well as overall system voltage stability (DSVSI. An index called system transmission quality factor (STQF has been developed to assess the power transmission quality of the overall system in the context of voltage stability. Two FACTS controllers, TCSC and STATCOM have also been incorporated in the present study to observe their effectiveness to ensure voltage stabilty. STATCOM has been found to be superior in order to improve voltage stability of power system as compared to TCSC. The developed concept has been validated using practical India Easten Grid (WBSEB system and it has a high potential of on-line application.

  7. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  8. Immediate Effects of Clock-Turn Strategy on the Pattern and Performance of Narrow Turning in Persons With Parkinson Disease.

    Science.gov (United States)

    Yang, Wen-Chieh; Hsu, Wei-Li; Wu, Ruey-Meei; Lin, Kwan-Hwa

    2016-10-01

    Turning difficulty is common in people with Parkinson disease (PD). The clock-turn strategy is a cognitive movement strategy to improve turning performance in people with PD despite its effects are unverified. Therefore, this study aimed to investigate the effects of the clock-turn strategy on the pattern of turning steps, turning performance, and freezing of gait during a narrow turning, and how these effects were influenced by concurrent performance of a cognitive task (dual task). Twenty-five people with PD were randomly assigned to the clock-turn or usual-turn group. Participants performed the Timed Up and Go test with and without concurrent cognitive task during the medication OFF period. The clock-turn group performed the Timed Up and Go test using the clock-turn strategy, whereas participants in the usual-turn group performed in their usual manner. Measurements were taken during the 180° turn of the Timed Up and Go test. The pattern of turning steps was evaluated by step time variability and step time asymmetry. Turning performance was evaluated by turning time and number of turning steps. The number and duration of freezing of gait were calculated by video review. The clock-turn group had lower step time variability and step time asymmetry than the usual-turn group. Furthermore, the clock-turn group turned faster with fewer freezing of gait episodes than the usual-turn group. Dual task increased the step time variability and step time asymmetry in both groups but did not affect turning performance and freezing severity. The clock-turn strategy reduces turning time and freezing of gait during turning, probably by lowering step time variability and asymmetry. Dual task compromises the effects of the clock-turn strategy, suggesting a competition for attentional resources.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, http://links.lww.com/JNPT/A141).

  9. Switching of charged inverse micelles in non-polar liquids.

    Science.gov (United States)

    Prasad, Manoj; Beunis, Filip; Neyts, Kristiaan; Strubbe, Filip

    2015-11-15

    The electrodynamics of micellar ions in nonpolar liquids are well understood for the case that a voltage is applied or switched off. In this work, the electrodynamics of charged inverse micelles (CIMs) are studied when the applied voltage is switched to the opposite polarity, which is relevant for applications such as electrophoretic displays and liquid toner printing. Transient current measurements are used to characterize the switching of CIMs formed in a solution of surfactant polyisobutylene succinimide in n-dodecane. For reverse voltages with amplitude below 10V the measurements are in good agreement with a drift and diffusion model, confirming the established understanding of CIMs in nonpolar liquids. When the charge content is high, the reversal current shows a characteristic peak which is explained on the basis of dynamic space-charge effects. However, for reverse voltages larger than 10V, the transient currents are influenced by electrohydrodynamic flow in the liquid causing the CIMs to switch faster than predicted by the model. The occurrence of electrohydrodynamic flow is verified by optical tracking of tracer particles. Also, when the polarizing voltage is applied for longer times, an additional current peak emerges which is due to the accumulation of newly generated charges at the electrodes. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Ring-extended gramicidin S analogs Containing cis δ-sugar amino acid turn mimetics with varying ring size

    NARCIS (Netherlands)

    Knijnenburg, A.D.; Spalburg, E.; Neeling, A.J. de; Mars-Groenendijk, R.H.; Noort, D.; Grotenbreg, G.M.; Marel, G.A. van der; Overkleeft, H.S.; Overhand, M.

    2012-01-01

    This article presents a series of ring-extended gramicidin S derivatives, 9-14, that have four ornithine residues as polar protonated side chains and one modified turn region containing a mono-functionalized cis-δ-oxetane, δ-furanoid, or δ-pyranoid sugar amino acid residue. Of the GS analogs

  11. Ferroelectric gate tunnel field-effect transistors with low-power steep turn-on

    Directory of Open Access Journals (Sweden)

    M. H. Lee

    2014-10-01

    Full Text Available Using a ferroelectric PbZrTiO3 gate stack, the range of the steep subthreshold swing in tunnel field-effect transistors was extended by 3.5 orders of magnitude demonstrating an improvement in the swing (by approximately double the slope. The drain conductance (gd shows only 16% enhancement with large V DS (∼−1.5V indicates internal voltage amplification with ferroelectric negative capacitance effect beneficial to small lateral drain-source bias voltages (−0.1 V. The concept of coupling the ferroelectric polarization is proposed. The power consumption is also discussed in low-power applications of steep subthreshold slope devices.

  12. Bank-to-turn control technology survey for homing missiles

    Science.gov (United States)

    Riedel, F. W.

    1980-01-01

    The potential advantages of bank-to-turn control are summarized. Recent and current programs actively investigating bank-to-turn steering are reviewed and critical technology areas concerned with bank-to-turn control are assessed.

  13. Asymptotic behaviour in polarized and half-polarized U(1) symmetric vacuum spacetimes

    International Nuclear Information System (INIS)

    Isenberg, James; Moncrief, Vincent

    2002-01-01

    We use the Fuchsian algorithm to study the behaviour near the singularity of certain families of U(1) symmetric solutions of the vacuum Einstein equations (with the U(1) isometry group acting spatially). We consider an analytic family of polarized solutions with the maximum number of arbitrary functions consistent with the polarization condition (one of the 'gravitational degrees of freedom' is turned off) and show that all members of this family are asymptotically velocity term dominated (AVTD) as one approaches the singularity. We show that the same AVTD behaviour holds for a family of 'half-polarized' solutions, which is defined by adding one extra arbitrary function to those characterizing the polarized solutions. (The full set of nonpolarized solutions involves two extra arbitrary functions.) Using SL(2, R) Geroch transformations, we produce a further class of U(1) symmetric solutions with AVTD behaviour. We begin to address the issue of whether AVTD behaviour is independent of the choice of time foliation by showing that indeed AVTD behaviour is seen for a wide class of choices of harmonic time in the polarized and half-polarized (U(1) symmetric vacuum) solutions discussed here

  14. Observation of pressure stimulated voltages in rocks using an electric potential sensor

    International Nuclear Information System (INIS)

    Aydin, A.; Prance, R. J.; Prance, H.; Harland, C. J.

    2009-01-01

    Recent interest in the electrical activity in rock and the use of electric field transients as candidates for earthquake precursors has led to studies of pressure stimulated currents in laboratory samples. In this paper, an electric field sensor is used to measure directly the voltages associated with these currents. Stress was applied as uniaxial compression to marble and granite at an approximately constant rate. In contrast with the small pressure stimulated currents previously measured, large voltage signals are reported. Polarity reversal of the signal was observed immediately before fracture for the marble, in agreement with previous pressure stimulated current studies.

  15. Charge-voltage relationship of the first impulse corona in long airgaps

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, P [Laboratoire Terre-Ocean, University of French Polynesia, BP 6570, 98702 Faaa, French Polynesia (France); Heilbronner, F [Institute of High Voltage Engineering and Electric Power Transmission, Technical University of Munich, D-80290 Munich (Germany); Ruehling, F [Institute of High Voltage Engineering and Electric Power Transmission, Technical University of Munich, D-80290 Munich (Germany); DIaz, R [High Voltage Laboratory, Institute of Electrical Engineering, National University of Tucuman, 4000 SM Tucuman (Argentina); Rodiere, M [Laboratoire Terre-Ocean, University of French Polynesia, BP 6570, 98702 Faaa, French Polynesia (France)

    2005-07-07

    This paper investigates the relationship between the charge Q{sub i} of the first impulse corona and the associated inception voltage U{sub i} for a 1 m point-plane airgap submitted to impulse voltages. Experimental studies under both polarities are reported; the Q{sub i}-U{sub i} characteristics obtained allow empirical quadratic relationships between these two quantities to be derived. A physical interpretation is proposed by considering the established characteristics of the first impulse corona. The Gauss and Ampere-Maxwell laws can be applied and the quadratic Q{sub i}-U{sub i} relationship is justified by the present model.

  16. Voltage-controlled spin selection in a magnetic resonant tunneling diode.

    Science.gov (United States)

    Slobodskyy, A; Gould, C; Slobodskyy, T; Becker, C R; Schmidt, G; Molenkamp, L W

    2003-06-20

    We have fabricated all II-VI semiconductor resonant tunneling diodes based on the (Zn,Mn,Be)Se material system, containing dilute magnetic material in the quantum well, and studied their current-voltage characteristics. When subjected to an external magnetic field the resulting spin splitting of the levels in the quantum well leads to a splitting of the transmission resonance into two separate peaks. This is interpreted as evidence of tunneling transport through spin polarized levels, and could be the first step towards a voltage controlled spin filter.

  17. Turning the Appliance Market Around towards A++

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen; Brange, Birgitte; Guldbrandsen, Tom

    2007-01-01

    in the course of a few years. Where models C, D, E earlier dominated the market, the A, A+ and A++, came to dominate as the standard models in stock. Consequently, their prices dropped significantly. The theory of a rational market behavior is based on some assumptions, one being that full information...... energy efficient model within their specification, and 4) in the website are also listed the shops, where consumers can get the appliances at lowest prices. The latter was the most innovative and maybe also the most effective measure in the package. Results showed up as a permanent U-turn of the market...... is available to all actors. The website identifying to the consumers the shops with the lowest priced efficient models was a step in that direction, and the result did not fail to turn up....

  18. Measurement of tool forces in diamond turning

    Energy Technology Data Exchange (ETDEWEB)

    Drescher, J.; Dow, T.A.

    1988-12-01

    A dynamometer has been designed and built to measure forces in diamond turning. The design includes a 3-component, piezoelectric transducer. Initial experiments with this dynamometer system included verification of its predicted dynamic characteristics as well as a detailed study of cutting parameters. Many cutting experiments have been conducted on OFHC Copper and 6061-T6 Aluminum. Tests have involved investigation of velocity effects, and the effects of depth and feedrate on tool forces. Velocity has been determined to have negligible effects between 4 and 21 m/s. Forces generally increase with increasing depth of cut. Increasing feedrate does not necessarily lead to higher forces. Results suggest that a simple model may not be sufficient to describe the forces produced in the diamond turning process.

  19. When attempts at robbing prey turn fatal

    Science.gov (United States)

    Dejean, Alain; Corbara, Bruno; Azémar, Frédéric; Carpenter, James M.

    2012-07-01

    Because group-hunting arboreal ants spread-eagle insect prey for a long time before retrieving them, these prey can be coveted by predatory flying insects. Yet, attempting to rob these prey is risky if the ant species is also an effective predator. Here, we show that trying to rob prey from Azteca andreae workers is a fatal error as 268 out of 276 potential cleptobionts (97.1 %) were captured in turn. The ant workers hunt in a group and use the "Velcro®" principle to cling firmly to the leaves of their host tree, permitting them to capture very large prey. Exceptions were one social wasp, plus some Trigona spp. workers and flies that landed directly on the prey and were able to take off immediately when attacked. We conclude that in this situation, previously captured prey attract potential cleptobionts that are captured in turn in most of the cases.

  20. RHIC Polarized proton operation

    International Nuclear Information System (INIS)

    Huang, H.; Ahrens, L.; Alekseev, I.G.; Aschenauer, E.; Atoian, G.; Bai, M.; Bazilevsky, A.; Blaskiewicz, M.; Brennan, J.M.; Brown, K.A.; Bruno, D.; Connolly, R.; Dion, A.; D'Ottavio, T.; Drees, K.A.; Fischer, W.; Gardner, C.; Glenn, J.W.; Gu, X.; Harvey, M.; Hayes, T.; Hoff, L.; Hulsart, R.L.; Laster, J.; Liu, C.; Luo, Y.; MacKay, W.W.; Makdisi, Y.; Marr, G.J.; Marusic, A.; Meot, F.; Mernick, K.; Michnoff, R.; Minty, M.; Montag, C.; Morris, J.; Nemesure, S.; Poblaguev, A.; Ptitsyn, V.; Ranjibar, V.; Robert-Demolaize, G.; Roser, T.; Schmidke, B.; Schoefer, V.; Severino, F.; Smirnov, D.; Smith, K.; Steski, D.; Svirida, D.; Tepikian, S.; Trbojevic, D.; Tsoupas, N.; Tuozzolo, J.E.; Wang, G.; Wilinski, M.; Yip, K.; Zaltsman, A.; Zelenski, A.; Zeno, K.; Zhang, S.Y.

    2011-01-01

    The Relativistic Heavy Ion Collider (RHIC) operation as the polarized proton collider presents unique challenges since both luminosity(L) and spin polarization(P) are important. With longitudinally polarized beams at the experiments, the figure of merit is LP 4 . A lot of upgrades and modifications have been made since last polarized proton operation. A 9 MHz rf system is installed to improve longitudinal match at injection and to increase luminosity. The beam dump was upgraded to increase bunch intensity. A vertical survey of RHIC was performed before the run to get better magnet alignment. The orbit control is also improved this year. Additional efforts are put in to improve source polarization and AGS polarization transfer efficiency. To preserve polarization on the ramp, a new working point is chosen such that the vertical tune is near a third order resonance. The overview of the changes and the operation results are presented in this paper. Siberian snakes are essential tools to preserve polarization when accelerating polarized beams to higher energy. At the same time, the higher order resonances still can cause polarization loss. As seen in RHIC, the betatron tune has to be carefully set and maintained on the ramp and during the store to avoid polarization loss. In addition, the orbit control is also critical to preserve polarization. The higher polarization during this run comes from several improvements over last run. First we have a much better orbit on the ramp. The orbit feedback brings down the vertical rms orbit error to 0.1mm, much better than the 0.5mm last run. With correct BPM offset and vertical realignment, this rms orbit error is indeed small. Second, the jump quads in the AGS improved input polarization for RHIC. Third, the vertical tune was pushed further away from 7/10 snake resonance. The tune feedback maintained the tune at the desired value through the ramp. To calibrate the analyzing power of RHIC polarimeters at any energy above

  1. RHIC Polarized proton operation

    Energy Technology Data Exchange (ETDEWEB)

    Huang, H.; Ahrens, L.; Alekseev, I.G.; Aschenauer, E.; Atoian, G.; Bai, M.; Bazilevsky, A.; Blaskiewicz, M.; Brennan, J.M.; Brown, K.A.; Bruno, D.; Connolly, R.; Dion, A.; D' Ottavio, T.; Drees, K.A.; Fischer, W.; Gardner, C.; Glenn, J.W.; Gu, X.; Harvey, M.; Hayes, T.; Hoff, L.; Hulsart, R.L.; Laster, J.; Liu, C.; Luo, Y.; MacKay, W.W.; Makdisi, Y.; Marr, G.J.; Marusic, A.; Meot, F.; Mernick, K.; Michnoff, R,; Minty, M.; Montag, C.; Morris, J.; Nemesure, S.; Poblaguev, A.; Ptitsyn, V.; Ranjibar, V.; Robert-Demolaize, G.; Roser, T.; J.; Severino, F.; Schmidke, B.; Schoefer, V.; Severino, F.; Smirnov, D.; Smith, K.; Steski, D.; Svirida, D.; Tepikian, S.; Trbojevic, D.; Tsoupas, N.; Tuozzolo, J. Wang, G.; Wilinski, M.; Yip, K.; Zaltsman, A.; Zelenski, A.; Zeno, K.; Zhang, S.Y.

    2011-03-28

    The Relativistic Heavy Ion Collider (RHIC) operation as the polarized proton collider presents unique challenges since both luminosity(L) and spin polarization(P) are important. With longitudinally polarized beams at the experiments, the figure of merit is LP{sup 4}. A lot of upgrades and modifications have been made since last polarized proton operation. A 9 MHz rf system is installed to improve longitudinal match at injection and to increase luminosity. The beam dump was upgraded to increase bunch intensity. A vertical survey of RHIC was performed before the run to get better magnet alignment. The orbit control is also improved this year. Additional efforts are put in to improve source polarization and AGS polarization transfer efficiency. To preserve polarization on the ramp, a new working point is chosen such that the vertical tune is near a third order resonance. The overview of the changes and the operation results are presented in this paper. Siberian snakes are essential tools to preserve polarization when accelerating polarized beams to higher energy. At the same time, the higher order resonances still can cause polarization loss. As seen in RHIC, the betatron tune has to be carefully set and maintained on the ramp and during the store to avoid polarization loss. In addition, the orbit control is also critical to preserve polarization. The higher polarization during this run comes from several improvements over last run. First we have a much better orbit on the ramp. The orbit feedback brings down the vertical rms orbit error to 0.1mm, much better than the 0.5mm last run. With correct BPM offset and vertical realignment, this rms orbit error is indeed small. Second, the jump quads in the AGS improved input polarization for RHIC. Third, the vertical tune was pushed further away from 7/10 snake resonance. The tune feedback maintained the tune at the desired value through the ramp. To calibrate the analyzing power of RHIC polarimeters at any energy above

  2. A combined compensation method for the output voltage of an insulated core transformer power supply.

    Science.gov (United States)

    Yang, L; Yang, J; Liu, K F; Qin, B; Chen, D Z

    2014-06-01

    An insulated core transformer (ICT) power supply is an ideal high-voltage generator for irradiation accelerators with energy lower than 3 MeV. However, there is a significant problem that the structure of the segmented cores leads to an increase in the leakage flux and voltage differences between rectifier disks. A high level of consistency in the output of the disks helps to achieve a compact structure by improving the utilization of both the rectifier components and the insulation distances, and consequently increase the output voltage of the power supply. The output voltages of the disks which are far away from the primary coils need to be improved to reduce their inhomogeneity. In this study, by investigating and comparing the existing compensation methods, a new combined compensation method is proposed, which increases the turns on the secondary coils and employs parallel capacitors to improve the consistency of the disks, while covering the entire operating range of the power supply. This method turns out to be both feasible and effective during the development of an ICT power supply. The non-uniformity of the output voltages of the disks is less than 3.5% from no-load to full-load, and the power supply reaches an output specification of 350 kV/60 mA.

  3. Abrasive Waterjet (AWJ) Titanium Tangental Turning Evaluation

    Czech Academy of Sciences Publication Activity Database

    Hloch, Sergej; Hlaváček, Petr; Vasilko, K.; Cárach, J.; Samardžič, I.; Kozak, D.; Ščučka, Jiří; Klich, Jiří; Klichová, Dagmar

    2014-01-01

    Roč. 53, č. 4 (2014), s. 537-540 ISSN 0543-5846 R&D Projects: GA MŠk ED2.1.00/03.0082 Institutional support: RVO:68145535 Keywords : titanium * abrasive waterjet turning * traverse speed Subject RIV: JQ - Machines ; Tools Impact factor: 0.959, year: 2014 http://public.carnet.hr/metalurg/Metalurgija/2014_vol_53/No_4/MET_53_4_537-540_Hloch.pdf

  4. Turning customer satisfaction measurements into action

    OpenAIRE

    Lervik-Olsen, Line; Witell, Lars; Gustafsson, Anders

    2014-01-01

    This is the authors’ final, accepted and refereed manuscript to the article. Publisher’s version available at http://dx.doi.org/10.1108/JOSM-01-2014-0025 Purpose – The purpose of this paper is to contribute to the literature on customer orientation by developing and empirically testing a model that attempts to explain the elements that constitute customer orientation and that, in turn, influence customer satisfaction. In particular, this study focuses on how service firms design, ...

  5. Turning points in climate change adaptation

    Directory of Open Access Journals (Sweden)

    Saskia Elisabeth. Werners

    2015-12-01

    Full Text Available Concerned decision makers increasingly pose questions as to whether current management practices are able to cope with climate change and increased climate variability. This signifies a shift in the framing of climate change from asking what its potential impacts are to asking whether it induces policy failure and unacceptable change. In this paper, we explore the background, feasibility, and consequences of this new framing. We focus on the specific situation in which a social-political threshold of concern is likely to be exceeded as a result of climate change, requiring consideration of alternative strategies. Action is imperative when such a situation is conceivable, and at this point climate change becomes particularly relevant to decision makers. We call this situation an "adaptation turning point." The assessment of adaptation turning points converts uncertainty surrounding the extent of a climate impact into a time range over which it is likely that specific thresholds will be exceeded. This can then be used to take adaptive action. Despite the difficulty in identifying adaptation turning points and the relative newness of the approach, experience so far suggests that the assessment generates a meaningful dialogue between stakeholders and scientists. Discussion revolves around the amount of change that is acceptable; how likely it is that unacceptable, or more favorable, conditions will be reached; and the adaptation pathways that need to be considered under these circumstances. Defining and renegotiating policy objectives under climate change are important topics in the governance of adaptation.

  6. FCC-hh turn-around cycle

    CERN Document Server

    Alemany Fernandez, Reyes; Bartmann, Wolfgang; Buffat, Xavier; Niemi, Arto; Schulte, Daniel; Solfaroli Camillocci, Matteo; Stoel, Linda

    2016-01-01

    The turn-around cycle time of a collider is defined as the time spent between the end of stable beams and the start of the next stable beams period, and its calculation is of fundamental importance. On one side it is a crucial ingredient for the computation of the optimal time spent in luminosity production, which defines the integrated luminosity per fill or store. On the other side, combined with the availability and reliability of the machine, it allows to perform a detailed breakdown of the operational performance of the collider over an operational season, i.e. percentage of time in stable beams and beam in the machine with respect to down time. This paper presents a preliminary operational cycle definition for the hadron-hadron Future Circular Collider, as a base line for estimating the corresponding turn-around time. The cycle definition is based on the Large Hadron Collider (LHC) operational cycle. Two turn-around times are presented, the theoretical one and a more realistic one based on the LHC exper...

  7. Our Polar Past

    Science.gov (United States)

    Clary, Renee; Wandersee, James

    2009-01-01

    The study of polar exploration is fascinating and offers students insights into the history, culture, and politics that affect the developing sciences at the farthest ends of Earth. Therefore, the authors think there is value in incorporating polar exploration accounts within modern science classrooms, and so they conducted research to test their…

  8. Terahertz polarization imaging

    NARCIS (Netherlands)

    Van der Valk, N.C.J.; Van der Marel, W.A.M.; Planken, P.C.M.

    2005-01-01

    We present a new method to measure the polarization state of a terahertz pulse by using a modified electrooptic sampling setup. To illustrate the power of this method, we show two examples in which the knowledge of the polarization of the terahertz pulse is essential for interpreting the results:

  9. Polarized proton beams

    International Nuclear Information System (INIS)

    Roser, T.

    1995-01-01

    The acceleration of polarized proton beams in circular accelerators is complicated by the presence of numerous depolarizing spin resonances. Careful and tedious minimization of polarization loss at each of these resonances allowed acceleration of polarized proton beams up to 22 GeV. It has been the hope that Siberian Snakes, which are local spin rotators inserted into ring accelerators, would eliminate these resonances and allow acceleration of polarized beams with the same ease and efficiency that is now routine for unpolarized beams. First tests at IUCF with a full Siberian Snake showed that the spin dynamics with a Snake can be understood in detail. The author now has results of the first tests of a partial Siberian Snake at the AGS, accelerating polarized protons to an energy of about 25 GeV. These successful tests of storage and acceleration of polarized proton beams open up new possibilities such as stored polarized beams for internal target experiments and high energy polarized proton colliders

  10. Polar Science Is Cool!

    Science.gov (United States)

    Weeks, Sophie

    2012-01-01

    Children are fascinated by the fact that polar scientists do research in extremely cold and dangerous places. In the Arctic they might be viewed as lunch by a polar bear. In the Antarctic, they could lose toes and fingers to frostbite and the wind is so fast it can rip skin off. They camp on ice in continuous daylight, weeks from any form of…

  11. Beam Optics Measurements Through Turn by Turn Beam Position Data in the SLS

    CERN Document Server

    Zisopoulos, P; Streun, A; Ziemann, v

    2013-01-01

    Refined Fourier analysis of turn-by-turn (TBT) transverse position data measurements can be used for determining several beam properties of a ring, such as transverse tunes, optics functions, phases, chromatic properties and coupling. In particular, the Numerical Analysis of Fundamental Frequencies (NAFF) algorithm is used to analyse TBT data from the Swiss Light Source (SLS) storage ring in order to estimate on and off-momentum beam characteristics. Of particular interest is the potential of using the full position information within one turn in order to measure beam optics properties.

  12. Simulation of Reactive Power Imbalances in the Transmission Power Grid Threatened by the Problem of Voltage Instability

    Directory of Open Access Journals (Sweden)

    Robert Lis

    2013-12-01

    Full Text Available The reactive power balance in the transmission power grid depends on the reactive power produced by the power stations and the value generated by the capacitive power lines and static compensators. Reactive transmission losses become greater than shunt capacitive generation at the turning-point of voltage stability. Then lowering bus voltages drive EPS into voltage collapse point. The paper presents the balance of reactive power depending on the power demand growth, which is then used to estimate the operating point of the transmission network, in which the reactive power transmission losses are greater than the total reactive power generated by the shunt capacity.

  13. Precision Polarization of Neutrons

    Science.gov (United States)

    Martin, Elise; Barron-Palos, Libertad; Couture, Aaron; Crawford, Christopher; Chupp, Tim; Danagoulian, Areg; Estes, Mary; Hona, Binita; Jones, Gordon; Klein, Andi; Penttila, Seppo; Sharma, Monisha; Wilburn, Scott

    2009-05-01

    Determining polarization of a cold neutron beam to high precision is required for the next generation neutron decay correlation experiments at the SNS, such as the proposed abBA and PANDA experiments. Precision polarimetry measurements were conducted at Los Alamos National Laboratory with the goal of determining the beam polarization to the level of 10-3 or better. The cold neutrons from FP12 were polarized using optically polarized ^3He gas as a spin filter, which has a highly spin-dependent absorption cross section. A second ^ 3He spin filter was used to analyze the neutron polarization after passing through a resonant RF spin rotator. A discussion of the experiment and results will be given.

  14. Optically polarized 3He

    Science.gov (United States)

    Gentile, T. R.; Nacher, P. J.; Saam, B.; Walker, T. G.

    2018-01-01

    This article reviews the physics and technology of producing large quantities of highly spin-polarized 3He nuclei using spin-exchange (SEOP) and metastability-exchange (MEOP) optical pumping. Both technical developments and deeper understanding of the physical processes involved have led to substantial improvements in the capabilities of both methods. For SEOP, the use of spectrally narrowed lasers and K-Rb mixtures has substantially increased the achievable polarization and polarizing rate. For MEOP nearly lossless compression allows for rapid production of polarized 3He and operation in high magnetic fields has likewise significantly increased the pressure at which this method can be performed, and revealed new phenomena. Both methods have benefitted from development of storage methods that allow for spin-relaxation times of hundreds of hours, and specialized precision methods for polarimetry. SEOP and MEOP are now widely applied for spin-polarized targets, neutron spin filters, magnetic resonance imaging, and precision measurements. PMID:29503479

  15. Optically polarized 3He

    Science.gov (United States)

    Gentile, T. R.; Nacher, P. J.; Saam, B.; Walker, T. G.

    2017-10-01

    This article reviews the physics and technology of producing large quantities of highly spin-polarized 3He nuclei using spin-exchange (SEOP) and metastability-exchange (MEOP) optical pumping. Both technical developments and deeper understanding of the physical processes involved have led to substantial improvements in the capabilities of both methods. For SEOP, the use of spectrally narrowed lasers and K-Rb mixtures has substantially increased the achievable polarization and polarizing rate. For MEOP nearly lossless compression allows for rapid production of polarized 3He and operation in high magnetic fields has likewise significantly increased the pressure at which this method can be performed, and revealed new phenomena. Both methods have benefitted from development of storage methods that allow for spin-relaxation times of hundreds of hours, and specialized precision methods for polarimetry. SEOP and MEOP are now widely applied for spin-polarized targets, neutron spin filters, magnetic resonance imaging, and precision measurements.

  16. Parallel Polarization State Generation.

    Science.gov (United States)

    She, Alan; Capasso, Federico

    2016-05-17

    The control of polarization, an essential property of light, is of wide scientific and technological interest. The general problem of generating arbitrary time-varying states of polarization (SOP) has always been mathematically formulated by a series of linear transformations, i.e. a product of matrices, imposing a serial architecture. Here we show a parallel architecture described by a sum of matrices. The theory is experimentally demonstrated by modulating spatially-separated polarization components of a laser using a digital micromirror device that are subsequently beam combined. This method greatly expands the parameter space for engineering devices that control polarization. Consequently, performance characteristics, such as speed, stability, and spectral range, are entirely dictated by the technologies of optical intensity modulation, including absorption, reflection, emission, and scattering. This opens up important prospects for polarization state generation (PSG) with unique performance characteristics with applications in spectroscopic ellipsometry, spectropolarimetry, communications, imaging, and security.

  17. Personal computer interface for temmperature measuring in the cutting process with turning

    International Nuclear Information System (INIS)

    Trajchevski, Neven; Filipovski, Velimir; Kuzinonovski, Mikolaj

    2004-01-01

    The computer development aided reserch systems in the investigations of the characteristics of the surface layar forms conditions for decreasing of the measuring uncertainty. Especially important is the fact that the usage of open and self made measuring systems accomplishes the demands for a total control of the research process. This paper describes an original personal computer interface which is used in the newly built computer aided reserrch system for temperatute measuring in the machining with turning. This interface consists of optically-coupled linear isolation amplifier and an analog to digital (A/D) converter. It is designed for measuring of the themo- voltage that is a generated from the natural thermocouple workpiece-cutting tool. That is achived by digitalizing the value of the thermo-voltage in data which is transmitted to the personal computer. The interface realization is a result of the research activity of the faculty of Mechanical Engineering and the Faculty of Electrical Engineering in Skopje.

  18. Beta Regression Finite Mixture Models of Polarization and Priming

    Science.gov (United States)

    Smithson, Michael; Merkle, Edgar C.; Verkuilen, Jay

    2011-01-01

    This paper describes the application of finite-mixture general linear models based on the beta distribution to modeling response styles, polarization, anchoring, and priming effects in probability judgments. These models, in turn, enhance our capacity for explicitly testing models and theories regarding the aforementioned phenomena. The mixture…

  19. Power conditioning using dynamic voltage restorers under different voltage sag types

    Directory of Open Access Journals (Sweden)

    Ahmed M. Saeed

    2016-01-01

    Full Text Available Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs. By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  20. An analytical turn-on power loss model for 650-V GaN eHEMTs

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Shen, Zhan

    2018-01-01

    This paper proposes an improved analytical turn-on power loss model for 650-V GaN eHEMTs. The static characteristics, i.e., the parasitic capacitances and transconductance, are firstly modeled. Then the turn-on process is divided into multiple stages and analyzed in detail; as results, the time-d......-domain solutions to the drain-source voltage and drain current are obtained. Finally, double-pulse tests are conducted to verify the proposed power loss model. This analytical model enables an accurate and fast switching behavior characterization and power loss prediction.......This paper proposes an improved analytical turn-on power loss model for 650-V GaN eHEMTs. The static characteristics, i.e., the parasitic capacitances and transconductance, are firstly modeled. Then the turn-on process is divided into multiple stages and analyzed in detail; as results, the time...

  1. A high frequency active voltage doubler in standard CMOS using offset-controlled comparators for inductive power transmission.

    Science.gov (United States)

    Lee, Hyung-Min; Ghovanloo, Maysam

    2013-06-01

    In this paper, we present a fully integrated active voltage doubler in CMOS technology using offset-controlled high speed comparators for extending the range of inductive power transmission to implantable microelectronic devices (IMD) and radio-frequency identification (RFID) tags. This active voltage doubler provides considerably higher power conversion efficiency (PCE) and lower dropout voltage compared to its passive counterpart and requires lower input voltage than active rectifiers, leading to reliable and efficient operation with weakly coupled inductive links. The offset-controlled functions in the comparators compensate for turn-on and turn-off delays to not only maximize the forward charging current to the load but also minimize the back current, optimizing PCE in the high frequency (HF) band. We fabricated the active voltage doubler in a 0.5-μm 3M2P std . CMOS process, occupying 0.144 mm(2) of chip area. With 1.46 V peak AC input at 13.56 MHz, the active voltage doubler provides 2.4 V DC output across a 1 kΩ load, achieving the highest PCE = 79% ever reported at this frequency. In addition, the built-in start-up circuit ensures a reliable operation at lower voltages.

  2. Assessing lexical, syntactic, and conceptual turn-by-turn alignment in conversations involving conflict and deception

    DEFF Research Database (Denmark)

    Duran, Nicholas; Fusaroli, Riccardo; Paxton, Alexandra

    2015-01-01

    -level linguistic alignment, we turn to a unique conversational context: one in which participants disagree or agree with each other about contentious sociopolitical topics, with the added element of one partner secretly taking a "devil's advocate" position. Our findings reveal that high-level intentional factors......Our goal is to present a novel systematic approach for automatically assessing conversational alignment across turn-by-turn exchanges, examining linguistic behavior at increasing levels of abstractness through lexical, syntactic, and conceptual similarity. Using the latest advances in Python......-based NLP tools, the procedure begins by taking conversational partners' turns and converting each into a lemmatized sequence of words, assigning part-of-speech tags and computing high-dimensional semantic vectors per each utterance. Words and part-of-speech tags are further sequenced into n-g! rams...

  3. High voltage load resistor array

    Science.gov (United States)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  4. Voltage-Controlled Floating Resistor Using DDCC

    Directory of Open Access Journals (Sweden)

    M. Kumngern

    2011-04-01

    Full Text Available This paper presents a new simple configuration to realize the voltage-controlled floating resistor, which is suitable for integrated circuit implementation. The proposed resistor is composed of three main components: MOS transistor operating in the non-saturation region, DDCC, and MOS voltage divider. The MOS transistor operating in the non-saturation region is used to configure a floating linear resistor. The DDCC and the MOS transistor voltage divider are used for canceling the nonlinear component term of MOS transistor in the non-saturation region to obtain a linear current/voltage relationship. The DDCC is employed to provide a simple summer of the circuit. This circuit offers an ease for realizing the voltage divider circuit and the temperature effect that includes in term of threshold voltage can be compensated. The proposed configuration employs only 16 MOS transistors. The performances of the proposed circuit are simulated with PSPICE to confirm the presented theory.

  5. Theoretical analysis of magnetic sensor output voltage

    International Nuclear Information System (INIS)

    Liu Haishun; Dun Chaochao; Dou Linming; Yang Weiming

    2011-01-01

    The output voltage is an important parameter to determine the stress state in magnetic stress measurement, the relationship between the output voltage and the difference in the principal stresses was investigated by a comprehensive application of magnetic circuit theory, magnetization theory, stress analysis as well as the law of electromagnetic induction, and a corresponding quantitative equation was derived. It is drawn that the output voltage is proportional to the difference in the principal stresses, and related to the angle between the principal stress and the direction of the sensor. This investigation provides a theoretical basis for the principle stresses measurement by output voltage. - Research highlights: → A comprehensive investigation of magnetic stress signal. → Derived a quantitative equation about output voltage and the principal stresses. → The output voltage is proportional to the difference of the principal stresses. → Provide a theoretical basis for the principle stresses measurement.

  6. Turn-by-Turn Analysis of Proton and Gold Beams at Injection in the AGS Booster

    International Nuclear Information System (INIS)

    Gardner, C.; Ahrens, L.; Williams, N.

    1999-01-01

    In this paper the authors describe the latest version of a program they have used for several years to acquire and analyze turn-by-turn data from pick-up electrodes in the AGS Booster during injection. The program determines several parameters of the injected beam including the tunes and the position and angle of the incoming beam. Examples are given for both proton and gold injection

  7. CERN PS Optical Properties Measured with Turn-By-Turn Orbit Data

    CERN Document Server

    Bach, T; Giovannozzi, M; Hernalsteens, C; Lachaize, A; Sterbini, G; Tom´as, R; Wasef, R

    2013-01-01

    The performance of the CERN Proton Synchrotron (PS) has been constantly increasing over the years both in terms of beam parameters (intensity and brightness) and beam manipulations (transverse and longitudinal splitting). This implies a very good knowledge of the linear and non-linear model of the ring. In this paper we report on a detailed campaign of beam measurements based on turn-by-turn orbit data aimed at measuring the optics in several conditions as well as the resonance driving terms.

  8. Hummingbirds control turning velocity using body orientation and turning radius using asymmetrical wingbeat kinematics.

    Science.gov (United States)

    Read, Tyson J G; Segre, Paolo S; Middleton, Kevin M; Altshuler, Douglas L

    2016-03-01

    Turning in flight requires reorientation of force, which birds, bats and insects accomplish either by shifting body position and total force in concert or by using left-right asymmetries in wingbeat kinematics. Although both mechanisms have been observed in multiple species, it is currently unknown how each is used to control changes in trajectory. We addressed this problem by measuring body and wingbeat kinematics as hummingbirds tracked a revolving feeder, and estimating aerodynamic forces using a quasi-steady model. During arcing turns, hummingbirds symmetrically banked the stroke plane of both wings, and the body, into turns, supporting a body-dependent mechanism. However, several wingbeat asymmetries were present during turning, including a higher and flatter outer wingtip path and a lower more deviated inner wingtip path. A quasi-steady analysis of arcing turns performed with different trajectories revealed that changes in radius were associated with asymmetrical kinematics and forces, and changes in velocity were associated with symmetrical kinematics and forces. Collectively, our results indicate that both body-dependent and -independent force orientation mechanisms are available to hummingbirds, and that these kinematic strategies are used to meet the separate aerodynamic challenges posed by changes in velocity and turning radius. © 2016 The Author(s).

  9. Mimicry by asx- and ST-turns of the four main types of β-turn in proteins

    OpenAIRE

    Duddy, William J.; Nissink, J. Willem M.; Allen, Frank H.; Milner-White, E. James

    2004-01-01

    Hydrogen-bonded β-turns in proteins occur in four categories: type I (the most common), type II, type II’, and type I’. Asx-turns resemble β-turns, in that both have an NH. . .OC hydrogen bond forming a ring of 10 atoms. Serine and threonine side chains also commonly form hydrogen-bonded turns, here called ST-turns. Asx-turns and ST-turns can be categorized into four classes, based on side chain rotamers and the conformation of the central turn residue, which are geometrically equivalent to t...

  10. Reactive Power Control for Voltage Management

    OpenAIRE

    Hasan, MD. Shakib

    2017-01-01

    This thesis presents methods for voltage management in distribution systems with high photovoltaic (PV) power production. The high PV penetration leads to both new challenges such as voltage profile violation and reverse power flow, and also new opportunities. Traditionally, the voltage control in the distribution network is achieved by common devices in the networks such as capacitor banks, static synchronous compensators (STATCOMs) and on-load tap changers (OLTCs). This thesis has considere...

  11. Modulation of UK lightning by heliospheric magnetic field polarity

    Science.gov (United States)

    Owens, M. J.; Scott, C. J.; Lockwood, M.; Barnard, L.; Harrison, R. G.; Nicoll, K.; Watt, C.; Bennett, A. J.

    2014-11-01

    Observational studies have reported solar magnetic modulation of terrestrial lightning on a range of time scales, from days to decades. The proposed mechanism is two-step: lightning rates vary with galactic cosmic ray (GCR) flux incident on Earth, either via changes in atmospheric conductivity and/or direct triggering of lightning. GCR flux is, in turn, primarily controlled by the heliospheric magnetic field (HMF) intensity. Consequently, global changes in lightning rates are expected. This study instead considers HMF polarity, which doesn't greatly affect total GCR flux. Opposing HMF polarities are, however, associated with a 40-60% difference in observed UK lightning and thunder rates. As HMF polarity skews the terrestrial magnetosphere from its nominal position, this perturbs local ionospheric potential at high latitudes and local exposure to energetic charged particles from the magnetosphere. We speculate as to the mechanism(s) by which this may, in turn, redistribute the global location and/or intensity of thunderstorm activity.

  12. A new inverter topology using GTO commutation. [Gate Turn Off thyristor

    Science.gov (United States)

    Rippel, W. E.

    1983-01-01

    A new N-phase, forced commutated bridge inverter topology has been developed wherein a single Gate Turn Off Thyristor (GTO) is used to commutate each of 2N main Thyristors (SCRs). Since, for most applications, the primary loss mechanism is the SCR forward drop, very high efficiencies are possible. Compared with conventional pure SCR and pure GTO inverters, cost per kW is lower - in the former case due to the large cost differential between GTOs and SCRs. Other advantages of the new inverter include high power density, low switching losses and stresses, modulation flexibility and amenability to high voltage and high frequency operation.

  13. Polarization at the SLC

    Energy Technology Data Exchange (ETDEWEB)

    Moffeit, K.C.

    1988-10-01

    The Stanford Linear collider was designed to accommodate polarized electron beams. Longitudinally polarized electrons colliding with unpolarized positrons at a center of mass energy near the Z/sup 0/ mass can be used as novel and sensitive probes of the electroweak process. A gallium arsenide based photon emission source will provide a beam of longitudinally polarized electrons of about 45 percent polarization. A system of bend magnets and a superconducting solenoid will be used to rotate the spins so that the polarization is preserved while the 1.21 GeV electrons are stored in the damping ring. Another set of bend magnets and two superconducting solenoids orient the spin vectors so that longitudinal polarization of the electrons is achieved at the collision point with the unpolarized positrons. A system to monitor the polarization based on Moller and Compton scattering will be used. Nearly all major components have been fabricated and tested. Subsystems of the source and polarimeters have been installed, and studies are in progress. The installation and commissioning of the entire system will take place during available machine shutdown periods as the commissioning of SLC progresses. 8 refs., 16 figs., 1 tab.

  14. Low-Voltage Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Bidari, E.; Keskin, M.; Maloberti, F.

    1999-01-01

    Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications.......Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications....

  15. DESIGN AND SIMULATION OF A HIGH PERFORMANCE CMOS VOLTAGE DOUBLERS USING CHARGE REUSE TECHNIQUE

    Directory of Open Access Journals (Sweden)

    SHAMIL H. HUSSEIN

    2017-12-01

    Full Text Available Voltage doubler (VD structure plays an important role in charge pump (CP circuits. It provides a voltages that is higher than the voltage of the power supply or a voltage of reverse polarity. In many applications such as the power IC and switched-capacitor transformers. This paper presents the design and analysis for VD using charge reuse technique CMOS 0.35µm tech. with high performance. Bootstrapped and charge reuse techniques is used to improve performance of integrated VD. Charge reusing method is based on equalizing the voltages of the pumping capacitances in each stage of CP. As a consequence, it reduces the load independent losses, improve the efficiency. Simulation using Orcad is applied for various VD structures shows improvement in charge reuse technique compared with existing counterpart. The results obtained show that the VD can be used in a wide band frequencies (0-100 MHz or greater. The charge reuse VD circuit provided a good efficiency about (87.6% and (83.5% for one stage and two stage respectively at pump capacitance of 57pf, load current of 1mA, frequency of 10 MHz and supply voltage is 3.5 V compared with one stage and two stage of a latched VD are (85.4% and (80% respectively.

  16. An analytical turn-on power loss model for 650-V GaN eHEMTs

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Shen, Zhan

    2018-01-01

    -domain solutions to the drain-source voltage and drain current are obtained. Finally, double-pulse tests are conducted to verify the proposed power loss model. This analytical model enables an accurate and fast switching behavior characterization and power loss prediction.......This paper proposes an improved analytical turn-on power loss model for 650-V GaN eHEMTs. The static characteristics, i.e., the parasitic capacitances and transconductance, are firstly modeled. Then the turn-on process is divided into multiple stages and analyzed in detail; as results, the time...

  17. Fluorescence turn on by cholate aggregates.

    Science.gov (United States)

    Baldridge, Anthony; Amador, Adrian; Tolbert, Laren M

    2011-04-05

    Bile salts, including sodium cholate (NaCh), are amphiphilic molecules with a concave hydrophilic side and a convex hydrophobic side. By forming aggregates in aqueous solution, these natural surfactants fulfill vital biological roles in the solubilization of cholesterol, lipids, and fat-soluble vitamins and thus are involved in the transport and absorption of important biological molecules. Following our success with the encapsulation of fluorescent protein chromophore (FP) analogs by synthetic hydrophobic and hydrophilic hosts, based upon substitution patterns, we now report the binding and turn on of other analogs by bile salt aggregates, observations which may lead to new tools for studying trafficking in these important systems.

  18. Turning a page of Agency history

    International Nuclear Information System (INIS)

    1969-01-01

    Recent developments, and especially the new and critical interest of developing countries, have helped to mark the turning of a page in the Agency's history. If the present situation in the economics of nuclear power does not change there is a danger that developing countries will lag further and further behind the advanced countries in its use. Shortage of resources impose a brake on Agency efforts to promote benefits of nuclear techniques, especially by technical assistance. These were some of the points made by Dr. Sigvard Eklund, the Director General, when he presented the Agency's annual report to the Economic and Social Council (ECOSOC) in July. (author)

  19. Polarized atomic beams for targets

    International Nuclear Information System (INIS)

    Grueebler, W.

    1984-01-01

    The basic principle of the production of polarized atomic hydrogen and deuterium beams are reviewed. The status of the present available polarization, density and intensity are presented. The improvement of atomic beam density by cooling the hydrogen atoms to low velocity is discussed. The possible use of polarized atomic beams as targets in storage rings is shown. It is proposed that polarized atomic beams can be used to produce polarized gas targets with high polarization and greatly improved density

  20. Polarized scintillator targets

    Science.gov (United States)

    van den Brandt, B.; Bunyatova, E. I.; Hautle, P.; Konter, J. A.; Mango, S.

    2000-05-01

    The hydrogen nuclei in an organic scintillator have been polarized to more than 80% and the deuterons in its fully deuterated version to 24%. The scintillator, doped with TEMPO, has been polarized dynamically in a field of 2.5 T in a vertical dilution refrigerator in which a plastic lightguide transports the scintillation light from the sample in the mixing chamber to a photomultiplier outside the cryostat. Sizeable solid samples with acceptable optical properties and light output have been prepared and successfully operated as "live" polarized targets in nuclear physics experiments.

  1. Polarized scintillator targets

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, B. van den E-mail: vandenbrandt@psi.ch; Bunyatova, E.I.; Hautle, P.; Konter, J.A.; Mango, S

    2000-05-21

    The hydrogen nuclei in an organic scintillator have been polarized to more than 80% and the deuterons in its fully deuterated version to 24%. The scintillator, doped with TEMPO, has been polarized dynamically in a field of 2.5 T in a vertical dilution refrigerator in which a plastic lightguide transports the scintillation light from the sample in the mixing chamber to a photomultiplier outside the cryostat. Sizeable solid samples with acceptable optical properties and light output have been prepared and successfully operated as 'live' polarized targets in nuclear physics experiments.

  2. Heidelberg polarized alkali source

    International Nuclear Information System (INIS)

    Kraemer, D.; Steffens, E.; Jaensch, H.; Philipps Universitaet, Marburg, Germany)

    1984-01-01

    A new atomic beam type polarized alkali ion source has been installed at Heidelberg. In order to improve the beam polarization considerably optical pumping is applied in combination with an adiabatic medium field transition which results in beams in single hyperfine sublevels. The m state population is determined by laser-induced fluorescence spectroscopy. Highly polarized beams (P/sub s/ > 0.9, s = z, zz) with intensities of 30 to 130 μA can be extracted for Li + and Na + , respectively

  3. Role of parasitic capacitances in power MOSFET turn-on switching speed limits

    DEFF Research Database (Denmark)

    Cittanti, Davide; Iannuzzo, Francesco; Hoene, Eckart

    2017-01-01

    This paper describes the effect of MOSFET internal capacitances on the channel current during the turn-on switching transition: an intrinsic theoretical switching speed limit is found and detailed mathematically. The set of analytical equations is solved and the effect of the displacement currents...... is highlighted with ideal simulated waveforms. A laboratory experiment is thus performed, in order to prove the theoretical predictions: a 25 mΩ SiC CREE power MOSFET is turned on in a no-load condition (zero drain current), starting from different drain-source voltage values. Finally, a LTSpice equivalent...... circuit model is also built, to better simulate the experimental behavior of the device, adding circuit strain components and other non-idealities to the overall model. A good match between measurements and simulations is observed, mostly validating either the theoretical assumptions and the presented...

  4. Detection of inter-turn faults in transformer winding using the capacitor discharge method

    Science.gov (United States)

    Michna, Michał; Wilk, Andrzej; Ziółko, Michał; Wołoszyk, Marek; Swędrowski, Leon; Szwangruber, Piotr

    2017-12-01

    The paper presents results of an analysis of inter-turn fault effects on the voltage and current waveforms of a capacitor discharge through transformer windings. The research was conducted in the frame of the Facility of Antiproton and Ion Research project which goal is to build a new international accelerator facility that utilizes superconducting magnets. For the sake of electrical quality assurance of the superconducting magnet circuits, a measurement and diagnostic system is currently under development at Gdansk University of Technology (GUT). Appropriate measurements and simulations of the special transformer system were performed to verify the proposed diagnostic method. In order to take into account the nonlinearity and hysteresis of the magnetic yoke, a novel mathematical model of the transformer was developed. A special test bench was constructed to emulate the inter-turn faults within transformer windings.

  5. Detection of inter-turn faults in transformer winding using the capacitor discharge method

    Directory of Open Access Journals (Sweden)

    Michna Michał

    2017-12-01

    Full Text Available The paper presents results of an analysis of inter-turn fault effects on the voltage and current waveforms of a capacitor discharge through transformer windings. The research was conducted in the frame of the Facility of Antiproton and Ion Research project which goal is to build a new international accelerator facility that utilizes superconducting magnets. For the sake of electrical quality assurance of the superconducting magnet circuits, a measurement and diagnostic system is currently under development at Gdansk University of Technology (GUT. Appropriate measurements and simulations of the special transformer system were performed to verify the proposed diagnostic method. In order to take into account the nonlinearity and hysteresis of the magnetic yoke, a novel mathematical model of the transformer was developed. A special test bench was constructed to emulate the inter-turn faults within transformer windings.

  6. Polarization measurement in the COMPASS polarized target

    CERN Document Server

    Kondo, K; Baum, G; Berglund, P; Doshita, N; Gautheron, F; Görtz, S; Hasegawa, T; Horikawa, N; Ishimoto, S; Iwata, T; Kisselev, Yu V; Koivuniemi, J H; Le Goff, J M; Magnon, A; Meyer, W; Reicherz, G; Matsuda, T

    2004-01-01

    Continuous wave nuclear magnetic resonance (NMR) is used to determine the target polarization in the COMPASS experiment. The system is made of the so-called Liverpool Q-meters, Yale-cards, and VME modules for data taking and system controlling. In 2001 the NMR coils were embedded in the target material, while in 2002 and 2003 the coils were mounted on the outer surface of the target cells to increase the packing factor of the material. Though the error of the measurement became larger with the outer coils than with the inner coils, we have performed stable measurements throughout the COMPASS run time for 3 years. The maximum polarization was +57% and -53% as the average in the target cells.

  7. Excitation of voltage oscillations in an induction voltage adder

    Directory of Open Access Journals (Sweden)

    Nichelle Bruner

    2009-07-01

    Full Text Available The induction voltage adder is an accelerator architecture used in recent designs of pulsed-power driven x-ray radiographic systems such as Sandia National Laboratories’ Radiographic Integrated Test Stand (RITS, the Atomic Weapons Establishment’s planned Hydrus Facility, and the Naval Research Laboratory’s Mercury. Each of these designs relies on magnetic insulation to prevent electron loss across the anode-cathode gap in the vicinity of the adder as well as in the coaxial transmission line. Particle-in-cell simulations of the RITS adder and transmission line show that, as magnetic insulation is being established during a pulse, some electron loss occurs across the gap. Sufficient delay in the cavity pulse timings provides an opportunity for high-momentum electrons to deeply penetrate the cavities of the adder cells where they can excite radio-frequency resonances. These oscillations may be amplified in subsequent gaps, resulting in oscillations in the output power. The specific modes supported by the RITS-6 accelerator and details of the mechanism by which they are excited are presented in this paper.

  8. Hatchability of chicken eggs as influenced by turning frequency in ...

    African Journals Online (AJOL)

    An experiment was conducted to determine the influence of turning frequency of chicken eggs on hatchability in hurricane lantern incubator. There were four treatments in which eggs were not turned in treatment one (control), those in treatment two were turned once daily (morning), treatment three turned twice daily ...

  9. Spin-polarized current generated by magneto-electrical gating

    International Nuclear Information System (INIS)

    Ma Minjie; Jalil, Mansoor Bin Abdul; Tan, Seng Ghee

    2012-01-01

    We theoretically study spin-polarized current through a single electron tunneling transistor (SETT), in which a quantum dot (QD) is coupled to non-magnetic source and drain electrodes via tunnel junctions, and gated by a ferromagnetic (FM) electrode. The I–V characteristics of the device are investigated for both spin and charge currents, based on the non-equilibrium Green's function formalism. The FM electrode generates a magnetic field, which causes a Zeeman spin-splitting of the energy levels in the QD. By tuning the size of the Zeeman splitting and the source–drain bias, a fully spin-polarized current is generated. Additionally, by modulating the electrical gate bias, one can effect a complete switch of the polarization of the tunneling current from spin-up to spin-down current, or vice versa. - Highlights: ► The spin polarized transport through a single electron tunneling transistor is systematically studied. ► The study is based on Keldysh non-equilibrium Green's function and equation of motion method. ► A fully spin polarized current is observed. ► We propose to reverse current polarization by the means of gate voltage modulation. ► This device can be used as a bi-polarization current generator.

  10. New series half-bridge converters with the balance input split capacitor voltages

    Science.gov (United States)

    Lin, Bor-Ren; Chiang, Huann-Keng; Wang, Shang-Lun

    2016-03-01

    This article presents a new dc/dc converter to perform the main functions of zero voltage switching (ZWS), low converter size, high switching frequency and low-voltage stress. Metal-oxide-semiconductor field-effect transistors (MOSFETs) with high switching frequency are used to reduce the converter size and increase circuit efficiency. To overcome low-voltage stress and high turn-on resistance of MOSFETs, the series half-bridge topology is adopted in the proposed converter. Hence, the low-voltage stress MOSFETs can be used for medium-input voltage applications. The asymmetric pulse-width modulation is used to generate the gating signals and achieve the ZWS. On the secondary side, the parallel connection of two diode rectifiers is adopted to reduce the current rating of passive components. On the primary side, the series connection of two transformers is used to balance two output inductor currents. Two flying capacitors are used to automatically balance the input split capacitor voltages. Finally, experiments with 1000 W rated power are performed to verify the theoretical analysis and the effectiveness of proposed converter.

  11. Polarization dynamics of VCSELs in external cavities

    Science.gov (United States)

    Marconi, M.; Javaloyes, J.; Barland, S.; Balle, S.; Giudici, M.

    2014-05-01

    We review the dynamics of VCSELs that experience both Polarization-Selective Feedback (PSF) and Crossed- Polarization Reinjection (XPR). Different regimes of regular pulsation were found. For strong enough XPR levels, the VCSEL emission in each of its linearly-polarized components displays a square-wave modulation which regularity is greatly enhanced by small levels of PSF. Such a square-wave is in antiphase for the two polarizations, and it turns out to be stable and robust over broad intervals of current. The frequency of the square-wave is determined by the length of the XPR arm. For weak levels of PSF and XPR, the VCSEL emits a regular train of short optical pulses arising from the locking of the modes in the PSF cavity. The frequency of the pulse train is stable on short time scales, but it wanders with a characteristic time scale of hundreds of roundtrips in the PSF cavity. The experimental results are successfully explained by an extension of the Spin-Flip Model that incorporates gain saturation and the effects of PSF and XPR.

  12. Retention of intermediate polarization states in ferroelectric materials enabling memories for multi-bit data storage

    Science.gov (United States)

    Zhao, Dong; Katsouras, Ilias; Asadi, Kamal; Groen, Wilhelm A.; Blom, Paul W. M.; de Leeuw, Dago M.

    2016-06-01

    A homogeneous ferroelectric single crystal exhibits only two remanent polarization states that are stable over time, whereas intermediate, or unsaturated, polarization states are thermodynamically instable. Commonly used ferroelectric materials however, are inhomogeneous polycrystalline thin films or ceramics. To investigate the stability of intermediate polarization states, formed upon incomplete, or partial, switching, we have systematically studied their retention in capacitors comprising two classic ferroelectric materials, viz. random copolymer of vinylidene fluoride with trifluoroethylene, P(VDF-TrFE), and Pb(Zr,Ti)O3. Each experiment started from a discharged and electrically depolarized ferroelectric capacitor. Voltage pulses were applied to set the given polarization states. The retention was measured as a function of time at various temperatures. The intermediate polarization states are stable over time, up to the Curie temperature. We argue that the remarkable stability originates from the coexistence of effectively independent domains, with different values of polarization and coercive field. A domain growth model is derived quantitatively describing deterministic switching between the intermediate polarization states. We show that by using well-defined voltage pulses, the polarization can be set to any arbitrary value, allowing arithmetic programming. The feasibility of arithmetic programming along with the inherent stability of intermediate polarization states makes ferroelectric materials ideal candidates for multibit data storage.

  13. Analysis of forces in ultrasonically assisted turning

    Science.gov (United States)

    Ahmed, N.; Mitrofanov, A. V.; Babitsky, V. I.; Silberschmidt, V. V.

    2007-12-01

    Many modern engineering materials are very difficult to process with conventional machining methods. Ultrasonically assisted turning (UAT) is a new technology, where high frequency vibration (frequency f≈20 kHz, amplitude a≈15 μm) is superimposed on the movement of the cutting tool. Compared to conventional turning (CT), UAT allows significant improvements in processing many intractable materials, such as high-strength aerospace alloys and composites, by producing a noticeable decrease in cutting forces and a superior surface finish. Vibro-impact interaction between the tool and workpiece in UAT during the chip formation leads to a dynamically changing cutting force in the process zone as compared to the quasistatic one in CT. The paper presents an experimental study and computational (finite-element) model of both CT and UAT. Forces acting on the cutting tool in UAT are studied, and their dependence on vibration amplitude, frequency and vibration direction as well as on cutting parameters, such as feed rate and cutting speed, are investigated.

  14. An electrostatic elliptical mirror for neutral polar molecules

    OpenAIRE

    Flórez, A. Isabel González; Meek, Samuel A.; Haak, Henrik; Conrad, Horst; Santambrogio, Gabriele; Meijer, Gerard

    2011-01-01

    Focusing optics for neutral molecules finds application in shaping and steering molecular beams. Here we present an electrostatic elliptical mirror for polar molecules consisting of an array of microstructured gold electrodes deposited on a glass substrate. Alternating positive and negative voltages applied to the electrodes create a repulsive potential for molecules in low-field-seeking states. The equipotential lines are parallel to the substrate surface, which is bent in an elliptical shap...

  15. Direct current voltage induced by microwave signal in a ferromagnetic wire

    OpenAIRE

    Yamaguchi, A.; Motoi, K.; Miyajima, H.; Nakatani, Y.

    2007-01-01

    Experimental results of rectification of a constant wave radio frequency (RF) current flowing in a single-layered ferromagnetic wire are presented. We show that a detailed external magnetic field dependence of the RF current induced a direct-current voltage spectrum. The mechanism of the rectification is discussed in a term of the spin transfer torque, and the rectification is closely related to resonant spin wave excitation with the assistant of the spin-polarized RF current. The micromagnet...

  16. A design for a high voltage magnet coil ringer test set

    International Nuclear Information System (INIS)

    Koska, W.; Sims, R.E.

    1992-01-01

    By discharging a bank of charged capacitors through a high power SCR switch into an SSC dipole magnet assembly, it is possible to ring the coil and develop a voltage stress of greater than 50 volts turn-to-turn, thereby verifying the insulation integrity. We will present an overview of the test set design for a 2 kV isolated SCR firing circuit, including safety features, selectable capacitor banks, and digital waveform storage system. Results from testing typical coils and magnets will be included. Possible upgrades are also discussed

  17. A design for a high voltage magnet coil ringer test set

    International Nuclear Information System (INIS)

    Koska, W.; Sims, R.E.

    1992-04-01

    By discharging a bank of charged capacitors through a high power SCR switch into an SSC dipole magnet assembly, it is possible to ''ring'' the coil and develop a voltage stress of greater than 50 volts turn-to-turn, thereby verifying the insulation integrity. We will present an overview of the test set design for a 2 kV isolated SCR firing circuit, including safety features, selectable capacitor banks, and digital waveform storage system. Results from testing typical coils and magnets will be included. Possible upgrades are also discussed

  18. Dynamic nuclear spin polarization

    Energy Technology Data Exchange (ETDEWEB)

    Stuhrmann, H.B. [GKSS-Forschungszentrum Geesthacht GmbH (Germany)

    1996-11-01

    Polarized neutron scattering from dynamic polarized targets has been applied to various hydrogenous materials at different laboratories. In situ structures of macromolecular components have been determined by nuclear spin contrast variation with an unprecedented precision. The experiments of selective nuclear spin depolarisation not only opened a new dimension to structural studies but also revealed phenomena related to propagation of nuclear spin polarization and the interplay of nuclear polarisation with the electronic spin system. The observation of electron spin label dependent nuclear spin polarisation domains by NMR and polarized neutron scattering opens a way to generalize the method of nuclear spin contrast variation and most importantly it avoids precontrasting by specific deuteration. It also likely might tell us more about the mechanism of dynamic nuclear spin polarisation. (author) 4 figs., refs.

  19. Time Domain Induced Polarization

    DEFF Research Database (Denmark)

    Fiandaca, Gianluca; Auken, Esben; Christiansen, Anders Vest

    2012-01-01

    Time-domain-induced polarization has significantly broadened its field of reference during the last decade, from mineral exploration to environmental geophysics, e.g., for clay and peat identification and landfill characterization. Though, insufficient modeling tools have hitherto limited the use...... of time-domaininduced polarization for wider purposes. For these reasons, a new forward code and inversion algorithm have been developed using the full-time decay of the induced polarization response, together with an accurate description of the transmitter waveform and of the receiver transfer function......%. Furthermore, the presence of low-pass filters in time-domain-induced polarization instruments affects the early times of the acquired decays (typically up to 100 ms) and has to be modeled in the forward response to avoid significant loss of resolution. The developed forward code has been implemented in a 1D...

  20. Polarized proton colliders

    International Nuclear Information System (INIS)

    Roser, T.

    1995-01-01

    High energy polarized beam collisions will open up the unique physics opportunities of studying spin effects in hard processes. This will allow the study of the spin structure of the proton and also the verification of the many well documented expectations of spin effects in perturbative QCD and parity violation in W and Z production. Proposals for polarized proton acceleration for several high energy colliders have been developed. A partial Siberian Snake in the AGS has recently been successfully tested and full Siberian Snakes, spin rotators, and polarimeters for RHIC are being developed to make the acceleration of polarized beams to 250 GeV possible. This allows for the unique possibility of colliding two 250 GeV polarized proton beams at luminosities of up to 2 x 10 32 cm -2 s -1

  1. DC Voltage Balance Control Strategy for Medium Voltage Cascaded STATCOM Based on Distributed Control

    OpenAIRE

    Xuehua Zhao; Liping Shi

    2014-01-01

    DC bus capacitors of Medium Voltage Cascaded STATCOM are independent. DC side voltage balance control method is the key influencing factor of current control. The imbalance of DC bus voltage increases harmonic current and affects the safety of device. In this paper, the unbalance mechanism of DC side capacitor voltage is analyzed. Based on the unipolar dual frequency and carrier phase-shifted SPWM (CPS-SPWM) modulation algorithms, the distributed control algorithms, which need multi- FPGA str...

  2. Voltage Unbalance Compensation with Smart Three-phase Loads

    DEFF Research Database (Denmark)

    Douglass, Philip; Trintis, Ionut; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design, proof-of-concept simulations and laboratory test of an algorithm for controlling active front-end rectifiers to reduce voltage unbalance. Using inputs of RMS voltage, the rectifier controller allocates load unevenly on its 3 phases to compensate for voltage...... are evaluated: one metric based on the maximum deviation of RMS phaseneutral voltage from the average voltage and one metric based on negative sequence voltage. The tests show that controller that uses phase-neutral voltage as input can in most cases eliminate the deviations of phase voltage from the average...... voltage, but it does not reduce the negative sequence voltage. The controller that uses phase-phase voltage as input eliminates negative sequence voltage, and reduces voltage deviations from the average to approximately half their initial value. Current unbalance is reduced when the voltage unbalance...

  3. Optimum transfer between hyperbolic asymptotes with turn angle less than the maximum natural turn angle.

    Science.gov (United States)

    Walton, J. M.; Marchal, C.; Culp, R. D.

    1971-01-01

    The impulsive transfer of minimum characteristic velocity between two given hyperbolic asymptotes associated with a real planet is considered. The constraint of remaining above the surface of the planet introduces a maximum natural turn angle. This divides the problem naively into two categories. The first is the case when the turn angle required by the given asymptotes is less than or equal to the maximum natural turn angle. This is the more reasonable situation for a swingby maneuver, and is the case considered in this paper. The resulting optimal transfers are of five basic types. In boundary conditions space, by far the largest area of transfers are either single impulse transfers or transfers through the parabolic level requiring two finite impulses. In no case has an optimal transfer been found which uses more than two finite impulses and three infinitesimal impulses. Complete results are presented for the case in which the given turn angle is less than or equal to the maximum natural turn angle.

  4. Plasma polarization spectroscopy

    International Nuclear Information System (INIS)

    Iwamae, Atsushi; Horimoto, Yasuhiro; Fujimoto, Takashi; Hasegawa, Noboru; Sukegawa, Kouta; Kawachi, Tetsuya

    2005-01-01

    The electron velocity distribution function (EVDF) in plasma can be anisotropic in laser-produced plasmas. We have developed a new technique to evaluate the polarization degree of the emission lines in the extreme vacuum ultra violet wavelength region. The polarization of the emission lines and the continuums from the lithium-like nitrogen and from helium- and hydrogen-like carbon in recombining plasma is evaluated. Particle simulation in the velocity space gives the time scale for relaxation of anisotropic EVDFs. (author)

  5. Ultracold Polar Molecules

    Science.gov (United States)

    2016-04-01

    AFRL-AFOSR-UK-TR-2016-0005 Ultracold Polar Molecules Jeremy Hutson UNIVERSITY OF DURHAM Final Report 04/01/2016 DISTRIBUTION A: Distribution approved...DATES COVERED (From - To) 15-Jan-2010 to 14-Jul-2015 4. TITLE AND SUBTITLE Final Report on Grant FA8655-10-1-3033 on Ultracold Polar Molecules 5a...formation of ultracold 87RbCs molecules in their rovibrational ground state by magnetoassociation followed by STIRAP, resulting in 14 papers acknowledging

  6. Asymmetric voltage behavior of the tunnel magnetoresistance in double barrier magnetic tunnel junctions

    KAUST Repository

    Useinov, Arthur

    2012-06-01

    In this paper, we study the value of the tunnel magnetoresistance (TMR) as a function of the applied voltage in double barrier magnetic tunnel junctions (DMTJs) with the left and right ferromagnetic (FM) layers being pinned and numerically estimate the possible difference of the TMR curves for negative and positive voltages in the homojunctions (equal barriers and electrodes). DMTJs are modeled as two single barrier junctions connected in series with consecutive tunneling (CST). We investigated the asymmetric voltage behavior of the TMR for the CST in the range of a general theoretical model. Significant asymmetries of the experimental curves, which arise due to different annealing regimes, are mostly explained by different heights of the tunnel barriers and asymmetries of spin polarizations in magnetic layers. © (2012) Trans Tech Publications.

  7. Voltage-Sensitive Load Controllers for Voltage Regulation and Increased Load Factor in Distribution Systems

    DEFF Research Database (Denmark)

    Douglass, Philip James; Garcia-Valle, Rodrigo; Østergaard, Jacob

    2014-01-01

    This paper presents a novel controller design for controlling appliances based on local measurements of voltage. The controller finds the normalized voltage deviation accounting for the sensitivity of voltage measurements to appliance state. The controller produces a signal indicating desired pow...

  8. Voltage stability in low voltage microgrids in aspects of active and reactive power demand

    Directory of Open Access Journals (Sweden)

    Parol Mirosław

    2016-03-01

    Full Text Available Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

  9. Grid Voltage Modulated Control of Grid-Connected Voltage Source Inverters under Unbalanced Grid Conditions

    DEFF Research Database (Denmark)

    Li, Mingshen; Gui, Yonghao; Quintero, Juan Carlos Vasquez

    2017-01-01

    In this paper, an improved grid voltage modulated control (GVM) with power compensation is proposed for grid-connected voltage inverters when the grid voltage is unbalanced. The objective of the proposed control is to remove the power ripple and to improve current quality. Three power compensation...

  10. Hsp Polarization Verification

    Science.gov (United States)

    Bless, Robert

    1991-07-01

    This proposal defines the procedure for determining the instrumental polarization of the polarimetric IDT (IDT#1, POL) on the HSP. 1 of 2 unpolarized standard stars wil be observed using various filter-polarizer combinations. These observations will permit the instrumental polarization to be calibrated. The instrumental polarization must be determined to a high precision in order to vectoriallly remove it from HSP polarization observations to determine the actual astronomical polarization. Final run of proposal will look at one of 2 possible stars previously observed to get another look at the throughput. Revision History: Mark H. Slovak 8/30/88 Translated to V2 proposal instructions (RPSS V6.2) S. Laurent 1/20/89 Updated: Sally Laurent 2/24/89, 3/20/89, 4/13/89, 5/12/89 Modified: P. Stanley 1/15/90 - change to use CTA selected targets only; Fixes for aberration problem - SALM 7/30/90; Based on SV/HSP 1386. New submission changed targets and revised scheduling strategy. Revised: 26 Aug 92 J. Dolan, L. Walter, P. Reppert want to re-run the proposal (3985) one last time to bring down errors.

  11. A polarity-induced defect mechanism for conductivity and magnetism at polar-nonpolar oxide interfaces.

    Science.gov (United States)

    Yu, Liping; Zunger, Alex

    2014-10-13

    The discovery of conductivity and magnetism at the polar-nonpolar interfaces of insulating nonmagnetic oxides such as LaAlO3 and SrTiO3 has raised prospects for attaining interfacial functionalities absent in the component materials. Yet, the microscopic origin of such emergent phenomena remains unclear, posing obstacles to design of improved functionalities. Here we present first principles calculations of electronic and defect properties of LaAlO3/SrTiO3 interfaces and reveal a unifying mechanism for the origins of both conductivity and magnetism. We demonstrate that the polar discontinuity across the interface triggers thermodynamically the spontaneous formation of certain defects that in turn cancel the polar field induced by the polar discontinuity. The ionization of the spontaneously formed surface oxygen vacancy defects leads to interface conductivity, whereas the unionized Ti-on-Al antisite defects lead to interface magnetism. The proposed mechanism suggests practical design principles for inducing and controlling both conductivity and magnetism at general polar-nonpolar interfaces.

  12. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  13. Low-Voltage Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Bidari, E.; Keskin, M.; Maloberti, F.

    1999-01-01

    Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications....

  14. Improving transition voltage spectroscopy of molecular junctions

    DEFF Research Database (Denmark)

    Markussen, Troels; Chen, Jingzhe; Thygesen, Kristian Sommer

    2011-01-01

    Transition voltage spectroscopy (TVS) is a promising spectroscopic tool for molecular junctions. The principles in TVS is to find the minimum on a Fowler-Nordheim plot where ln(I/V2) is plotted against 1/V and relate the voltage at the minimum Vmin to the closest molecular level. Importantly, Vmin...

  15. Reduced Voltage Scaling in Clock Distribution Networks

    Directory of Open Access Journals (Sweden)

    Khader Mohammad

    2009-01-01

    Full Text Available We propose a novel circuit technique to generate a reduced voltage swing (RVS signals for active power reduction on main buses and clocks. This is achieved without performance degradation, without extra power supply requirement, and with minimum area overhead. The technique stops the discharge path on the net that is swinging low at a certain voltage value. It reduces active power on the target net by as much as 33% compared to traditional full swing signaling. The logic 0 voltage value is programmable through control bits. If desired, the reduced-swing mode can also be disabled. The approach assumes that the logic 0 voltage value is always less than the threshold voltage of the nMOS receivers, which eliminate the need of the low to high voltage translation. The reduced noise margin and the increased leakage on the receiver transistors using this approach have been addressed through the selective usage of multithreshold voltage (MTV devices and the programmability of the low voltage value.

  16. Technical feasibility study of Voltage Optimization Unit

    DEFF Research Database (Denmark)

    Hu, Junjie; Marinelli, Mattia; Coppo, Massimiliano

    are used as load basics for the analysis. In term of PV genera-tion profiles, a realistic PV output power is assumed. Four relevant indicies such as phase neutral voltage, netural potential voltage, unbalanced factor (VUF), and power losses are evaluated in the present study. The simulation tests include...

  17. Voltage-gated lipid ion channels

    DEFF Research Database (Denmark)

    Blicher, Andreas; Heimburg, Thomas Rainer

    2013-01-01

    probability as a function of voltage. The voltage-dependence of the lipid pores is found comparable to that of protein channels. Lifetime distributions of open and closed events indicate that the channel open distribution does not follow exponential statistics but rather power law behavior for long open times...

  18. Low-Voltage Continuous Electrospinning Patterning.

    Science.gov (United States)

    Li, Xia; Li, Zhaoying; Wang, Liyun; Ma, Guokun; Meng, Fanlong; Pritchard, Robyn H; Gill, Elisabeth L; Liu, Ye; Huang, Yan Yan Shery

    2016-11-30

    Electrospinning is a versatile technique for the construction of microfibrous and nanofibrous structures with considerable potential in applications ranging from textile manufacturing to tissue engineering scaffolds. In the simplest form, electrospinning uses a high voltage of tens of thousands volts to draw out ultrafine polymer fibers over a large distance. However, the high voltage limits the flexible combination of material selection, deposition substrate, and control of patterns. Prior studies show that by performing electrospinning with a well-defined "near-field" condition, the operation voltage can be decreased to the kilovolt range, and further enable more precise patterning of fibril structures on a planar surface. In this work, by using solution dependent "initiators", we demonstrate a further lowering of voltage with an ultralow voltage continuous electrospinning patterning (LEP) technique, which reduces the applied voltage threshold to as low as 50 V, simultaneously permitting direct fiber patterning. The versatility of LEP is shown using a wide range of combination of polymer and solvent systems for thermoplastics and biopolymers. Novel functionalities are also incorporated when a low voltage mode is used in place of a high voltage mode, such as direct printing of living bacteria; the construction of suspended single fibers and membrane networks. The LEP technique reported here should open up new avenues in the patterning of bioelements and free-form nano- to microscale fibrous structures.

  19. The LMF triaxial MITL voltage adder system

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Smith, D.L.; Bennett, L.F.; Lockner, T.R.; Olson, R.E.; Poukey, J.W.

    1992-01-01

    The light-ion microfusion driver design consists of multiple accelerating modules fired in coincidence and sequentially in order to provide the desired ion energy, power pulse shape and energy deposition uniformity on an Inertial Confinement Fusion (ICF) target. The basic energy source is a number of Marx generators which, through the appropriate pulse power conditioning, provide the necessary voltage pulse wave form to the accelerating gaps or feeds of each module. The cavity gaps are inductively isolated, and the voltage addition occurs in the center conductor of the voltage adder which is the positive electrode while the electrons of the sheath flow closer to the outer cylinder which is the magnetically insulated cathode electrode. Each module powers a separate two-stage extraction diode which provides a low divergence ion beam. In order to provide the two separate voltage pulses required by the diode, a triaxial adder system is designed for each module. The voltage addition occurs in two separate MITLs. The center hollow cylinder (anode) of the second MITL also serves as the outer cathode electrode for the extension of the first voltage adder MITL. The voltage of the second stage is about twice that of the first stage. The cavities are connected in series to form the outer cylinder of each module. The accelerating modules are positioned radially in a symmetrical way around the fusion chamber. A preliminary conceptual design of the LMF modules with emphasis on the voltage adders and extension MITLs will be presented and discussed

  20. Wide-range voltage modulation

    International Nuclear Information System (INIS)

    Rust, K.R.; Wilson, J.M.

    1992-06-01

    The Superconducting Super Collider's Medium Energy Booster Abort (MEBA) kicker modulator will supply a current pulse to the abort magnets which deflect the proton beam from the MEB ring into a designated beam stop. The abort kicker will be used extensively during testing of the Low Energy Booster (LEB) and the MEB rings. When the Collider is in full operation, the MEBA kicker modulator will abort the MEB beam in the event of a malfunction during the filling process. The modulator must generate a 14-μs wide pulse with a rise time of less than 1 μs, including the delay and jitter times. It must also be able to deliver a current pulse to the magnet proportional to the beam energy at any time during ramp-up of the accelerator. Tracking the beam energy, which increases from 12 GeV at injection to 200 GeV at extraction, requires the modulator to operate over a wide range of voltages (4 kV to 80 kV). A vacuum spark gap and a thyratron have been chosen for test and evaluation as candidate switches for the abort modulator. Modulator design, switching time delay, jitter and pre-fire data are presented

  1. NO Removal with Repetitive Discharges Caused by Reciprocal Traveling Wave Voltage Pulse in a Coaxial Cable

    Science.gov (United States)

    Yamaga, Keisuke; Kadowaki, Kazunori; Nishimoto, Sakae; Kitani, Isamu

    This paper describes experimental results of NO removal using barrier discharges produced by a reciprocal pulse generator. When a coaxial cable is charged and then grounded at one end of the cable without any resistance, a reciprocal traveling voltage pulse is repeatedly applied to a barrier-type reactor at the opposite end with a change in its polarity. 50% streamer initiation voltage for the reciprocal pulse generator was much smaller than that with the self-matched pulse generator having a matching resistance. The reason for the low initiation voltage in the reciprocal pulse was that space charges which accumulated on the barrier surface during cable charging had an effect on field enhancement in the reactor after the first polarity reversal. High speed photographs of discharge light produced by the reciprocal pulse showed that the voltage oscillation caused by one switching induced alternate propagation of positive and negative streamers with a very high frequency. In measurements of NO concentration, the reciprocal pulse generator gave a better performance for NO removal ratio than the self-matched pulse generator even though the stored energy in the recipocal pulse generator was very low.

  2. Secondary reverse streamer observed in an ester insulating liquid under negative impulse voltage

    International Nuclear Information System (INIS)

    Liu, Q; Wang, Z D

    2011-01-01

    The so-called 'secondary reverse streamer (SRS)' in this study depicts a newly observed streamer-in-liquid phenomenon which subsequently occurs well after the extinction of the primary streamer (PS) propagation within a single shot of negative impulse voltage and has reverse polarity to the PS. Tests were carried out in a synthetic ester liquid at a 50 mm needle-plane gap under negative impulse voltages up to 140 kV. Based on the current and light waveforms as well as the photographic images, two types of SRS were found: one has a bright trunk with a high velocity of 9.79 km s -1 belonging to the 3rd mode streamer; and the other has a weak tree-like channel with a low velocity of 1.28 km s -1 resembling the 2nd mode streamer. It should be emphasized that SRS under negative impulse voltages has positive polarity being opposite to the negative PS, which is believed to be due to the reverse electric field induced by the residual space charges left by the PS. This has been confirmed by further verification tests under tail-chopped impulse voltages, for SRSs are significantly enhanced in both axial and lateral directions after the early removal of the external applied field.

  3. Threshold voltages and optical retardation of deformed flexoelectric nematic layers with asymmetric surface anchoring

    Science.gov (United States)

    Derfel, G.; Buczkowska, M.

    2013-06-01

    Deformations of homeotropically aligned flexoelectric nematic layers induced by dc electric fields were simulated numerically. Two different anchoring strengths on the limiting surfaces were assumed. Nematic material was characterised by negative dielectric anisotropy. Both signs of the sum of flexoelectric coefficients were taken into account. The electric properties of the layer were described in terms of a weak electrolyte model. Mobility of cations was assumed to be one order of magnitude lower than that of anions. Quasi-blocking electrode contacts were assumed. The threshold voltages for deformations were determined by means of calculations of the phase difference Φ between ordinary and extraordinary light rays passing through a layer placed between crossed polarisers. The threshold values depended on the polarity of the bias voltage U. When the threshold value was exceeded, the phase difference increased with the voltage. Two different Φ(U/Uthreshold) dependencies for the two polarities of the voltage were found for each layer if the nematic possessed the flexoelectric properties. The possibility of using this effect to detect the flexoelectricity in the nematic was explored by simulated experiments. The effectiveness of the proposed method is discussed.

  4. Practical considerations in voltage stability assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kundur, P.; Gao, B. [Powertech Labs. Inc., Surrey, BC (Canada)

    1994-12-31

    This paper deals with some of the most important practical issues related to voltage stability assessment of large practical systems. A brief discussion of the practical aspects of voltage stability problem and prevention of voltage instability is given first, followed by descriptions of different analytical techniques and tools for voltage stability analysis. Presentations of analytical tools is focused on the VSTAB program which incorporates the modal analysis, continuation power flow, and shortest distance to instability techniques, Finally, an example case study of a practical large system is presented. The case study illustrates how modal analysis is used to determine the most effective load shedding scheme for preventing voltage instability. (author) 15 refs., 2 figs., 2 tabs.

  5. Coordinated Voltage Control of Active Distribution Network

    Directory of Open Access Journals (Sweden)

    Xie Jiang

    2016-01-01

    Full Text Available This paper presents a centralized coordinated voltage control method for active distribution network to solve off-limit problem of voltage after incorporation of distributed generation (DG. The proposed method consists of two parts, it coordinated primal-dual interior point method-based voltage regulation schemes of DG reactive powers and capacitors with centralized on-load tap changer (OLTC controlling method which utilizes system’s maximum and minimum voltages, to improve the qualified rate of voltage and reduce the operation numbers of OLTC. The proposed coordination has considered the cost of capacitors. The method is tested using a radial edited IEEE-33 nodes distribution network which is modelled using MATLAB.

  6. Voltage Balancer for Electric Double Layer Capacitors

    Science.gov (United States)

    Mori, Kazuya; Takahashi, Shingo; Hasebe, Akio; Seki, Sumiko; Itoh, Takahiko

    Decrease in energy density of the storage system with several electric double layer capacitors (EDLCs) is caused by imbalance of voltage for each EDLC. In case of low power applications, conventional voltage balancer with constant voltage circuits is useful. However, it has some problems for high power applications such as electric vehicle. We have developed a new system to balance the voltage of EDLCs by removing a little energy. In any case, the system can store the energy in each EDLC equally. In the present research, a prototype of voltage balancer is produced for making use of a number of EDLCs and evaluated. The results confirm that the system is effective and suitable for high power applications.

  7. Effect of III-nitride polarization on V{sub OC} in p-i-n and MQW solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Namkoong, Gon; Boland, Patrick; Foe, Kurniawan; Latimer, Kevin [Department of Electrical and Computer Engineering, Old Dominion University, Applied Research Center, 12050 Jefferson Avenue, Newport News, VA 23606 (United States); Bae, Si-Young; Shim, Jae-Phil; Lee, Dong-Seon [School of Information and Communications, Gwangju Institute of Science and Technology, 261 Cheomdan-gwagiro (Oryong-dong), Buk-gu, Gwangju 500-712 (Korea, Republic of); Jeon, Seong-Ran [Korea Photonics Technology Institute, 971-35, Wolchul-dong, Buk-gu, Gwangju, 500-779 (Korea, Republic of); Doolittle, W. Alan [School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States)

    2011-02-15

    We performed detailed studies of the effect of polarization on III-nitride solar cells. Spontaneous and piezoelectric polarizations were assessed to determine their impacts upon the open circuit voltages (V{sub OC}) in p-i(InGaN)-n and multi-quantum well (MQW) solar cells. We found that the spontaneous polarization in Ga-polar p-i-n solar cells strongly modifies energy band structures and corresponding electric fields in a way that degrades V{sub OC} compared to non-polar p-i-n structures. In contrast, we found that piezoelectric polarization in Ga-polar MQW structures does not have a large influence on V{sub OC} compared to non-polar MQW structures. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Simulation of Drastic Lag Phenomena in GaAs-Based FETs for Large Voltage Swing

    Directory of Open Access Journals (Sweden)

    K. Horio

    2001-01-01

    Full Text Available Turn-on characteristics of GaAs MESFETs and HEMTs are simulated when the gate voltage is changed abruptly. The gate-lag or slow current transient becomes more pronounced when the off-state gate voltage is more negative, because the surface-state effects or substrate-trap effects become more significant. Changes of I–V curves of GaAs MESFETs, when the drain voltage is swept with different speeds, are also simulated. When the swept time is short, the curve shows overshoot-like behavior and the kink disappears, indicating that the I–V characteristics should be quite different between DC and RF conditions.

  9. Energy Storage System with Voltage Equalization Strategy for Wind Energy Conversion

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2012-07-01

    Full Text Available In this paper, an energy storage system with voltage equalization strategy for wind energy conversion is presented. The proposed energy storage system provides a voltage equalization strategy for series-connected lead-acid batteries to increase their total storage capacity and lifecycle. In order to draw the maximum power from the wind energy, a perturbation-and-observation method and digital signal processor (DSP are incorporated to implement maximum power point tracking (MPPT algorithm and power regulating scheme. In the proposed energy storage system, all power switches have zero-voltage-switching (ZVS feature at turn-on transition. Therefore, the conversion efficiency can be increased. Finally, a prototype energy storage system for wind energy conversion is built and implemented. Experimental results have verified the performance and feasibility of the proposed energy storage system for wind energy conversion.

  10. A 765 mW high-voltage switching ADSL line-driver

    Science.gov (United States)

    De Gezelle, V.; Doutreloigne, J.; Van Calster, A.

    2005-12-01

    With the increasing popularity of ADSL-modems, there is a stringent need to develop highly efficient line-drivers. Currently most line-drivers use linear amplifiers, such as class AB. Due to the nature of the DMT-encoded signal, the efficiency of such amplifiers is limited. Another issue is the transformer turns ratio and the resulting supply voltage of the amplifier. In general, a high-voltage supply is needed. In this paper, a high-voltage switching differential amplifier using a 50 V supply is described. The maximum efficiency into a matched load yields over 40%, with an efficiency of 13.1% for a full downstream signal while maintaining a minimum MTPR of 40 dB. The circuit is processed in a 100 V, 0.7 μm technology.

  11. Polarized Light Microscopy

    Science.gov (United States)

    Frandsen, Athela F.

    2016-01-01

    Polarized light microscopy (PLM) is a technique which employs the use of polarizing filters to obtain substantial optical property information about the material which is being observed. This information can be combined with other microscopy techniques to confirm or elucidate the identity of an unknown material, determine whether a particular contaminant is present (as with asbestos analysis), or to provide important information that can be used to refine a manufacturing or chemical process. PLM was the major microscopy technique in use for identification of materials for nearly a century since its introduction in 1834 by William Fox Talbot, as other techniques such as SEM (Scanning Electron Microscopy), FTIR (Fourier Transform Infrared spectroscopy), XPD (X-ray Powder Diffraction), and TEM (Transmission Electron Microscopy) had not yet been developed. Today, it is still the only technique approved by the Environmental Protection Agency (EPA) for asbestos analysis, and is often the technique first applied for identification of unknown materials. PLM uses different configurations in order to determine different material properties. With each configuration additional clues can be gathered, leading to a conclusion of material identity. With no polarizing filter, the microscope can be used just as a stereo optical microscope, and view qualities such as morphology, size, and number of phases. With a single polarizing filter (single polars), additional properties can be established, such as pleochroism, individual refractive indices, and dispersion staining. With two polarizing filters (crossed polars), even more can be deduced: isotropy vs. anisotropy, extinction angle, birefringence/degree of birefringence, sign of elongation, and anomalous polarization colors, among others. With the use of PLM many of these properties can be determined in a matter of seconds, even for those who are not highly trained. McCrone, a leader in the field of polarized light microscopy, often

  12. Hard turning micro-machine tool

    Science.gov (United States)

    DeVor, Richard E; Adair, Kurt; Kapoor, Shiv G

    2013-10-22

    A micro-scale apparatus for supporting a tool for hard turning comprises a base, a pivot coupled to the base, an actuator coupled to the base, and at least one member coupled to the actuator at one end and rotatably coupled to the pivot at another end. A tool mount is disposed on the at least one member. The at least one member defines a first lever arm between the pivot and the tool mount, and a second lever arm between the pivot and the actuator. The first lever arm has a length that is less than a length of the second lever arm. The actuator moves the tool mount along an arc.

  13. Turned Back: Mad Men as Intermedial Melodrama

    Directory of Open Access Journals (Sweden)

    Monique Rooney

    2012-09-01

    Full Text Available This essay draws on definitions of gesture (Giorgio Agamben and Peter Brooks and catachresis (Peter Brooks, Jacques Derrida to examine the primacy of non-verbal signifiers as communicators of meaning in AMC’s Mad Men. Beginning with an analysis of Mad Men’s credit sequence, it draws attention to Mad Men’s use of gesture and catachresis in relation to melodrama’s privileging of non-verbal and naturalistic expression and its persistence as an intermedial mode that has moved back and forth between various media (theatre, novel, cinema, television and now digital formats. It argues that Mad Men’s melodramatic aesthetic is one that obliquely, and via a gestural and rhetorical ‘turned back’, communicates its relation to the past and the present.

  14. MEDIACRACY TURNS INTO A SYNONYM OF MEDIOCRITY?

    Directory of Open Access Journals (Sweden)

    Valentina CHIPER

    2014-11-01

    Full Text Available The link between freedom of speech and democracy is based on ideological legitimacy report. A new phenomenon which is worth noticing is the conversion of the freedom of expression from a freedom seen in certain aspects as a solitary freedom into a communication of the masses. Another challenge is prompted by the change of the traditional communication system at the dawn of technology, Internet and its various applications, as well as of the channels used. A weak point is the change in the values scale. If a journalist or a book is deemed good or valuable in terms of competence and ideas, these values are now unfortunately inspired by what we watch on TV. In this train of thoughts, reliable opinion leaders are no longer the same. Mediacracy turns into a synonym of mediocrity with affectivity and emotion prevailing over reason and instead of the communication of thoughts and opinions.

  15. Autism genes keep turning up chromatin.

    Science.gov (United States)

    Lasalle, Janine M

    2013-06-19

    Autism-spectrum disorders (ASD) are complex genetic disorders collectively characterized by impaired social interactions and language as well as repetitive and restrictive behaviors. Of the hundreds of genes implicated in ASD, those encoding proteins acting at neuronal synapses have been most characterized by candidate gene studies. However, recent unbiased genome-wide analyses have turned up a multitude of novel candidate genes encoding nuclear factors implicated in chromatin remodeling, histone demethylation, histone variants, and the recognition of DNA methylation. Furthermore, the chromatin landscape of the human genome has been shown to influence the location of de novo mutations observed in ASD as well as the landscape of DNA methylation underlying neurodevelopmental and synaptic processes. Understanding the interactions of nuclear chromatin proteins and DNA with signal transduction pathways and environmental influences in the developing brain will be critical to understanding the relevance of these ASD candidate genes and continued uncovering of the "roots" of autism etiology.

  16. Introduction: The Participatory Turn in Urbanism

    Directory of Open Access Journals (Sweden)

    Maroš Krivý

    2014-08-01

    Full Text Available This issue of Footprint examines the recent participatory turn in urban planning and urban design. It discusses the co-opting of participatory processes by planning departments, the systematic disregard of inequalities, and the empowering of the market resulting from the ‘anti-statism’ present in many participatory schemes.What is the relationship between the institutionalisation of participation and the practices of autonomy, self-organisation, and inclusion? When and how does genuine empowerment of collectives take place? Does the demand for the empowerment of local organisations and communities strengthen the market forces at the expense of central government?This issue attempts to problematise ‘participation’, to call attentions to some of its shortcomings, deficits, and limitations, not in order to necessarily bypass the demand for the democratisation of the urban, but in order to rectify and strengthen it.

  17. The experience turn as ‘bandwagon’

    DEFF Research Database (Denmark)

    Fuglsang, Lars; Eide, Dorthe

    2013-01-01

    further central processes, namely appropriation and narrowing the workspace. One Norwegian and one Danish network are studied using a case methodology. They are two rural networks of mainly small tourism firms. The empirical study confirms and illustrates how the bandwagon effect involves these three core......This paper uses the bandwagon metaphor to analyse, in two rural contexts, how small tourism firms become engaged in the idea of the experience economy and how the idea is turned into practice through network formation and innovation. In developing a practice-based approach we use the bandwagon...... metaphor to conceptualize network formation and innovation in terms of a ‘journey’. Following the practice-based literature on bandwagons, the journey starts by labelling an idea that is broad enough to give meaning to, and pull together, a number of diverse supporters. The journey also depends on two...

  18. Turning Video Resource Management into Cloud Computing

    Directory of Open Access Journals (Sweden)

    Weili Kou

    2016-07-01

    Full Text Available Big data makes cloud computing more and more popular in various fields. Video resources are very useful and important to education, security monitoring, and so on. However, issues of their huge volumes, complex data types, inefficient processing performance, weak security, and long times for loading pose challenges in video resource management. The Hadoop Distributed File System (HDFS is an open-source framework, which can provide cloud-based platforms and presents an opportunity for solving these problems. This paper presents video resource management architecture based on HDFS to provide a uniform framework and a five-layer model for standardizing the current various algorithms and applications. The architecture, basic model, and key algorithms are designed for turning video resources into a cloud computing environment. The design was tested by establishing a simulation system prototype.

  19. Reliability of supply of switchgear for auxiliary low voltage in substations extra high voltage to high voltage

    Directory of Open Access Journals (Sweden)

    Perić Dragoslav M.

    2015-01-01

    Full Text Available Switchgear for auxiliary low voltage in substations (SS of extra high voltages (EHV to high voltage (HV - SS EHV/HV kV/kV is of special interest for the functioning of these important SS, as it provides a supply for system of protection and other vital functions of SS. The article addresses several characteristic examples involving MV lines with varying degrees of independence of their supply, and the possible application of direct transformation EHV/LV through special voltage transformers. Auxiliary sources such as inverters and diesel generators, which have limited power and expensive energy, are also used for the supply of switchgear for auxiliary low voltage. Corresponding reliability indices are calculated for all examples including mean expected annual engagement of diesel generators. The applicability of certain solutions of switchgear for auxiliary low voltage SS EHV/HV, taking into account their reliability, feasibility and cost-effectiveness is analyzed too. In particular, the analysis of applications of direct transformation EHV/LV for supply of switchgear for auxiliary low voltage, for both new and existing SS EHV/HV.

  20. A Compact Imaging Detector of Polarization and Spectral Content

    Science.gov (United States)

    Rust, D. M.; Kumar, A.; Thompson, K. E.

    1993-01-01

    A new type of image detector will simultaneously analyze the polarization of light at all picture elements in a scene. The integrated Dual Imaging Detector (IDID) consists of a polarizing beam splitter bonded to a charge-coupled device (CCD), with signal-analysis circuitry and analog-to-digital converters, all integrated on a silicon chip. The polarizing beam splitter can be either a Ronchi ruling, or an array of cylindrical lenslets, bonded to a birefringent wafer. The wafer, in turn, is bonded to the CCD so that light in the two orthogonal planes of polarization falls on adjacent pairs of pixels. The use of a high-index birefringent material, e.g., rutile, allows the IDID to operate at f-numbers as high as f/3.5. Other aspects of the detector are discussed.

  1. Acceleration of polarized protons in the IHEP accelerator complex

    International Nuclear Information System (INIS)

    Anferov, V.A.; Ado, Yu.M.; Shoumkin, D.

    1995-01-01

    The paper considers possibility to accelerate polarized beam in the IHEP accelerator complex (including first stage of the UNK). The scheme of preserving beam polarization is described for all acceleration stages up to 400 GeV beam energy. Polarization and intensity of the polarized proton beam are estimated. The suggested scheme includes using two Siberian snakes in opposite straight sections of the UNK-1, where each snake consists of five dipole magnets. In the U-70 it is suggested to use one helical Siberian snake, which is turned on adiabatically at 10 GeV, and four pulsed quadrupoles. To incorporate the snake into the accelerator lattice it is proposed to make modification of one superperiod. This would make a 13 m long straight section. Spin depolarization in the Booster is avoided by decreasing the extraction energy to 0.9 GeV. Then no additional hardware is required in the Booster

  2. Tribological and electrochemical characteristics of DLC coatings with bias voltage

    Science.gov (United States)

    Kim, Woo-Jung; Kim, Jung-Gu; Park, Se Jun; Lee, Kwang-Ryeol

    2005-12-01

    Diamond-like carbon (DLC) coatings were deposited on a STS 316L substrate by means of R.F plasma-assisted chemical vapor deposition (R.F PACVD) technique using benzene (C6H6) as a reaction gas. The tribological and electrochemical characteristics of the DLC coatings were investigated by a tribological technique (wear test) and by electrochemical techniques (potentiodynamic polarization test and electrochemical impedance spectroscopy). Surface analyses of the DLC coatings were conducted by means of scanning electron microscopy and atomic force microscopy. This study provides reliable and quantitative data for an assessment of the effect of bias voltage on tribological and electrochemical characteristics in a simulated body fluid environment (0.89 wt.% NaCl of pH 7.4 at 37°C). From the results of the tribological and electrochemical techniques, wear and corrosion resistance of the DLC coatings were improved owing to the low surface roughness, low porosity and good adhesion strength. Among all DLC coatings in this experiment, the DLC coating with a bias voltage of -800 V showed better wear and corrosion resistance than did other coatings

  3. The evolution of tensor polarization

    International Nuclear Information System (INIS)

    Huang, H.; Lee, S.Y.; Ratner, L.

    1993-01-01

    By using the equation of motion for the vector polarization, the spin transfer matrix for spin tensor polarization, the spin transfer matrix for spin tensor polarization is derived. The evolution equation for the tensor polarization is studied in the presence of an isolate spin resonance and in the presence of a spin rotor, or snake

  4. Unpinning of rotating spiral waves in cardiac tissues by circularly polarized electric fields

    Science.gov (United States)

    Feng, Xia; Gao, Xiang; Pan, De-Bei; Li, Bing-Wei; Zhang, Hong

    2014-04-01

    Spiral waves anchored to obstacles in cardiac tissues may cause lethal arrhythmia. To unpin these anchored spirals, comparing to high-voltage side-effect traditional therapies, wave emission from heterogeneities (WEH) induced by the uniform electric field (UEF) has provided a low-voltage alternative. Here we provide a new approach using WEH induced by the circularly polarized electric field (CPEF), which has higher success rate and larger application scope than UEF, even with a lower voltage. And we also study the distribution of the membrane potential near an obstacle induced by CPEF to analyze its mechanism of unpinning. We hope this promising approach may provide a better alternative to terminate arrhythmia.

  5. 3-D time-domain induced polarization tomography: a new approach based on a source current density formulation

    Science.gov (United States)

    Soueid Ahmed, A.; Revil, A.

    2018-04-01

    Induced polarization (IP) of porous rocks can be associated with a secondary source current density, which is proportional to both the intrinsic chargeability and the primary (applied) current density. This gives the possibility of reformulating the time domain induced polarization (TDIP) problem as a time-dependent self-potential-type problem. This new approach implies a change of strategy regarding data acquisition and inversion, allowing major time savings for both. For inverting TDIP data, we first retrieve the electrical resistivity distribution. Then, we use this electrical resistivity distribution to reconstruct the primary current density during the injection/retrieval of the (primary) current between the current electrodes A and B. The time-lapse secondary source current density distribution is determined given the primary source current density and a distribution of chargeability (forward modelling step). The inverse problem is linear between the secondary voltages (measured at all the electrodes) and the computed secondary source current density. A kernel matrix relating the secondary observed voltages data to the source current density model is computed once (using the electrical conductivity distribution), and then used throughout the inversion process. This recovered source current density model is in turn used to estimate the time-dependent chargeability (normalized voltages) in each cell of the domain of interest. Assuming a Cole-Cole model for simplicity, we can reconstruct the 3-D distributions of the relaxation time τ and the Cole-Cole exponent c by fitting the intrinsic chargeability decay curve to a Cole-Cole relaxation model for each cell. Two simple cases are studied in details to explain this new approach. In the first case, we estimate the Cole-Cole parameters as well as the source current density field from a synthetic TDIP data set. Our approach is successfully able to reveal the presence of the anomaly and to invert its Cole

  6. Electrical access to critical coupling of circularly polarized waves in graphene chiral metamaterials.

    Science.gov (United States)

    Kim, Teun-Teun; Oh, Sang Soon; Kim, Hyeon-Don; Park, Hyun Sung; Hess, Ortwin; Min, Bumki; Zhang, Shuang

    2017-09-01

    Active control of polarization states of electromagnetic waves is highly desirable because of its diverse applications in information processing, telecommunications, and spectroscopy. However, despite the recent advances using artificial materials, most active polarization control schemes require optical stimuli necessitating complex optical setups. We experimentally demonstrate an alternative-direct electrical tuning of the polarization state of terahertz waves. Combining a chiral metamaterial with a gated single-layer sheet of graphene, we show that transmission of a terahertz wave with one circular polarization can be electrically controlled without affecting that of the other circular polarization, leading to large-intensity modulation depths (>99%) with a low gate voltage. This effective control of polarization is made possible by the full accessibility of three coupling regimes, that is, underdamped, critically damped, and overdamped regimes by electrical control of the graphene properties.

  7. Elimination of polarization degeneracy in circularly symmetric bianisotropic waveguides: a decoupled case.

    Science.gov (United States)

    Xu, Jing; Wu, Bingbing; Chen, Yuntian

    2015-05-04

    Mode properties of circularly symmetric waveguides with one special type of bianisotropy are studied using finite element approach. We find that the polarization degeneracy in circularly symmetric waveguides can be eliminated, by introducing intrinsic crossing coupling between electric and magnetic moments in the constituent units of the waveguide media. Breaking the polarization degeneracy in high order mode groups is also confirmed numerically. With the bianisotropic parameters chosen in this work, the x and y-polarized modes remain decoupled. Typically, the y-polarized modes remain completely unchanged, while the x-polarized modes are turned into leaky modes that are lossy along propagation direction. A perturbation model from coupled mode theory is developed to explain the results and shows excellent agreement. Such asymmetric behavior between different polarizations might be feasible and useful for developing compact polarizers in terahertz or mid-infrared regime.

  8. Polarized Electrons at Jefferson Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sinclair, C.K.

    1997-12-31

    The CEBAF accelerator at Jefferson laboratory can deliver CW electron beams to three experimental halls simultaneously. A large fraction of the approved scientific program at the lab requires polarized electron beams. Many of these experiments, both polarized and unpolarized, require high average beam current as well. Since all electrons delivered to the experimental halls originate from the same cathode, delivery of polarized beam to a single hall requires using the polarized source to deliver beam to all experiments in simultaneous operation. The polarized source effort at Jefferson Lab is directed at obtaining very long polarized source operational lifetimes at high average current and beam polarization; at developing the capability to deliver all electrons leaving the polarized source to the experimental halls; and at delivering polarized beam to multiple experimental halls simultaneously.initial operational experience with the polarized source will be presented.

  9. Polarized electrons at Jefferson laboratory

    International Nuclear Information System (INIS)

    The CEBAF accelerator at Jefferson laboratory can deliver CW electron beams to three experimental halls simultaneously. A large fraction of the approved scientific program at the lab requires polarized electron beams. Many of these experiments, both polarized and unpolarized, require high average beam current as well. Since all electrons delivered to the experimental halls originate from the same cathode, delivery of polarized beam to a single hall requires using the polarized source to deliver beam to all experiments in simultaneous operation. The polarized source effort at Jefferson Lab is directed at obtaining very long polarized source operational lifetimes at high average current and beam polarization; at developing the capability to deliver all electrons leaving the polarized source to the experimental halls; and at delivering polarized beam to multiple experimental halls simultaneously. Initial operational experience with the polarized source will be presented

  10. Polar low monitoring

    Science.gov (United States)

    Bobylev, Leonid; Zabolotskikh, Elizaveta; Mitnik, Leonid

    2010-05-01

    Polar lows are intense mesoscale atmospheric low pressure weather systems, developing poleward of the main baroclinic zone and associated with high surface wind speeds. Small size and short lifetime, sparse in-situ observations in the regions of their development complicate polar low study. Our knowledge of polar lows and mesocyclones has come almost entirely during the period of satellite remote sensing since, by virtue of their small horizontal scale, it was rarely possible to analyse these lows on conventional weather charts using only the data from the synoptic observing network. However, the effects of intense polar lows have been felt by coastal communities and seafarers since the earliest times. These weather systems are thought to be responsible for the loss of many small vessels over the centuries, although the nature of the storms was not understood and their arrival could not be predicted. The actuality of the polar low research is stipulated by their high destructive power: they are a threat to such businesses as oil and gas exploration, fisheries and shipping. They could worsen because of global warming: a shrinking of sea ice around the North Pole, which thawed to its record minimum in the summer of 2007, is likely to give rise to more powerful storms that form only over open water and can cause hurricane-strength winds. Therefore, study of polar lows, their timely detection, tracking and forecasting represents a challenge for today meteorology. Satellite passive microwave data, starting from Special Sensor Microwave Imager (SSM/I) onboard Defense Meteorological Satellite Program (DMSP) satellite, remain invaluable source of regularly available remotely sensed data to study polar lows. The sounding in this spectral range has several advantages in comparison with observations in visible and infrared ranges and Synthetic Aperture Radar (SAR) data: independence on day time and clouds, regularity and high temporal resolution in Polar Regions. Satellite

  11. Turn-by-Turn Imaging of the Transverse Beam Profile in PEP-II

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Alan A.; Petree, Mark; /SLAC

    2006-12-18

    During injection or instability, the transverse profile of an individual bunch in a storage ring can change significantly in a few turns. However, most synchrotron-light imaging techniques are not designed for this time scale. We have developed a novel diagnostic that enhances the utility of a fast gated camera by adding, inexpensively, some features of a dual-axis streak camera, in order to watch the turn-by-turn evolution of the transverse profile, in both x and y. The beam's elliptical profile is reshaped using cylindrical lenses to form a tall and narrow ellipse--essentially the projection of the full ellipse onto one transverse axis. We do this projection twice, by splitting the beam into two paths at different heights, and rotating the ellipse by 90{sup o} on one path. A rapidly rotating mirror scans these vertical ''pencils'' of light horizontally across the photocathode of the camera, which is gated for 3 ns on every Nth ring turn. A single readout of the camera captures 100 images, looking like a stroboscopic photograph of a moving object. We have observed the capture of injected charge into a bunch and the rapid change of beam size at the onset of a fast instability.

  12. Turning to Ontology in STS? Turning to STS through ‘Ontology’

    NARCIS (Netherlands)

    van Heur, B.; Leydesdorff, L.; Wyatt, S.

    2012-01-01

    We examine the evidence for the claim of an ‘ontological turn’ in science and technology studies (STS). Despite an increase in references to ‘ontology’ in STS since 1989, we show that there has not so much been an ontological turn as multiple discussions deploying the language of ontology,

  13. Polarized photon transport through fog

    Science.gov (United States)

    Farmer, Jonathan; Persons, Christopher M.; DeSilva, Robert; Kirkland, James H.; Finney, Greg A.; Fuller, Kirk A.; Hokr, Brett H.

    2017-09-01

    Anyone who has driven through fog understands the detrimental effect scattering can have on your ability to see. When light interacts with a scattering center, in this case a fog droplet, it is scattered into a new direction, ultimately turning the world around you into a dull gray haze. In some fogs, visibility can be less than 100 meters. It would be possible to see through turbid media like fog if you can separate the scattered light from the unscattered, or ballistic, light; however, we must understand the light transport properties of the atmosphere to determine the optimum scheme. Here, we present an end-to-end simulation for polarized light transport through fog. Our approach can be summarized in three steps: compute the Mueller matrix for a single scattering interaction, ensemble average a distribution of sizes and shapes, and solve the light transport using a Monte Carlo simulation. For small spherical particles, such as fog, we use Mie theory to calculate the single scattering Mueller matrix, but this approach can be generalized to non-spherical particles using ray tracing for large particles or a T-matrix approach for smaller particles. Through this simulation, we are able to determine a backscattering Mueller matrix and a forward scattering Mueller matrix response function for the atmosphere as a function of position and detection angle.

  14. Polarized protons at RHIC

    International Nuclear Information System (INIS)

    Tannenbaum, M.J.

    1990-12-01

    The Physics case is presented for the use of polarized protons at RHIC for one or two months each year. This would provide a facility with polarizations of approx-gt 50% high luminosity ∼2.0 x 10 32 cm -2 s -1 , the possibility of both longitudinal and transverse polarization at the interaction regions, and frequent polarization reversal for control of systematic errors. The annual integrated luminosity for such running (∼10 6 sec per year) would be ∫ Ldt = 2 x 10 38 cm -2 -- roughly 20 times the total luminosity integrated in ∼ 10 years of operation of the CERN Collider (∼10 inverse picobarns, 10 37 cm -2 ). This facility would be unique in the ability to perform parity-violating measurements and polarization test of QCD. Also, the existence of p-p collisions in a new energy range would permit the study of ''classical'' reactions like the total cross section and elastic scattering, etc., and serve as a complement to measurements from p-bar p colliders. 11 refs

  15. The Bochum Polarized Target

    International Nuclear Information System (INIS)

    Reicherz, G.; Goertz, S.; Harmsen, J.; Heckmann, J.; Meier, A.; Meyer, W.; Radtke, E.

    2001-01-01

    The Bochum 'Polarized Target' group develops the target material 6 LiD for the COMPASS experiment at CERN. Several different materials like alcohols, alcanes and ammonia are under investigation. Solid State Targets are polarized in magnetic fields higher than B=2.5T and at temperatures below T=1K. For the Dynamic Nuclear Polarization process, paramagnetic centers are induced chemically or by irradiation with ionizing beams. The radical density is a critical factor for optimization of polarization and relaxation times at adequate magnetic fields and temperatures. In a high sensitive EPR--apparatus, an evaporator and a dilution cryostat with a continuous wave NMR--system, the materials are investigated and optimized. To improve the polarization measurement, the Liverpool NMR-box is modified by exchanging the fixed capacitor for a varicap diode which not only makes the tuning very easy but also provides a continuously tuned circuit. The dependence of the signal area upon the circuit current is measured and it is shown that it follows a linear function

  16. In-line Fiber Polarizer

    OpenAIRE

    Perumalsamy, Priya

    1998-01-01

    Polarizers and polarization devices are important components in fiber optic communication and sensor systems. There is a growing need for efficient low loss components that are compatible with optical fibers. An all fiber in-line polarizer is a more desirable alternative that could be placed at appropriate intervals along communication links. An in-line fiber polarizer was fabricated and tested. The in-line fiber polarizer operates by coupling optical energy propagatin...

  17. Design of a TW-SLIM Module for Dual Polarity Confinement, Transport, and Reactions

    Science.gov (United States)

    Garimella, Sandilya V. B.; Webb, Ian K.; Prabhakaran, Aneesh; Attah, Isaac K.; Ibrahim, Yehia M.; Smith, Richard D.

    2017-07-01

    Here we describe instrumental approaches for performing dual polarity ion confinement, transport, ion mobility separations, and reactions in structures for lossless ion manipulations (SLIM). Previous means of ion confinement in SLIM, based upon rf-generated pseudopotentials and DC fields for lateral confinement, cannot trap ions of opposite polarity simultaneously. Here we explore alternative approaches to provide simultaneous lateral confinement of both ion polarities. Traveling wave ion mobility (IM) separations experienced in such SLIM cause ions of both polarities to migrate in the same directions and exhibit similar separations. The ion motion (and relative motion of the two polarities) under both surfing and IM separation conditions are discussed. In surfing conditions the two polarities are transported losslessly and non-reactively in their respective potential minima (higher absolute voltage regions confine negative polarities, and lower absolute potential regions are populated by positive polarities). In separation mode, where ions roll over an overtaking traveling wave, the two polarities can interact during the rollovers. Strategies to minimize overlap of the two ion populations to prevent reactive losses during separations are presented. A theoretical treatment of the time scales over which two populations (injected into a DC field-free region of the dual polarity SLIM device) interact is considered, and SLIM designs for allowing ion/ion interactions and other manipulations with dual polarities at 4 Torr are presented.

  18. Fuel Cell/Electrochemical Cell Voltage Monitor

    Science.gov (United States)

    Vasquez, Arturo

    2012-01-01

    A concept has been developed for a new fuel cell individual-cell-voltage monitor that can be directly connected to a multi-cell fuel cell stack for direct substack power provisioning. It can also provide voltage isolation for applications in high-voltage fuel cell stacks. The technology consists of basic modules, each with an 8- to 16-cell input electrical measurement connection port. For each basic module, a power input connection would be provided for direct connection to a sub-stack of fuel cells in series within the larger stack. This power connection would allow for module power to be available in the range of 9-15 volts DC. The relatively low voltage differences that the module would encounter from the input electrical measurement connection port, coupled with the fact that the module's operating power is supplied by the same substack voltage input (and so will be at similar voltage), provides for elimination of high-commonmode voltage issues within each module. Within each module, there would be options for analog-to-digital conversion and data transfer schemes. Each module would also include a data-output/communication port. Each of these ports would be required to be either non-electrical (e.g., optically isolated) or electrically isolated. This is necessary to account for the fact that the plurality of modules attached to the stack will normally be at a range of voltages approaching the full range of the fuel cell stack operating voltages. A communications/ data bus could interface with the several basic modules. Options have been identified for command inputs from the spacecraft vehicle controller, and for output-status/data feeds to the vehicle.

  19. Mimicry by asx- and ST-turns of the four main types of beta-turn in proteins.

    Science.gov (United States)

    Duddy, William J; Nissink, J Willem M; Allen, Frank H; Milner-White, E James

    2004-11-01

    Hydrogen-bonded beta-turns in proteins occur in four categories: type I (the most common), type II, type II', and type I'. Asx-turns resemble beta-turns, in that both have an NH. . .OC hydrogen bond forming a ring of 10 atoms. Serine and threonine side chains also commonly form hydrogen-bonded turns, here called ST-turns. Asx-turns and ST-turns can be categorized into four classes, based on side chain rotamers and the conformation of the central turn residue, which are geometrically equivalent to the four types of beta-turns. We propose asx- and ST-turns be named using the type I, II, I', and II' beta-turn nomenclature. Using this, the frequency of occurrence of both asx- and ST-turns is: type II' > type I > type II > type I', whereas for beta-turns it is type I > type II > type I' > type II'. Almost all type II asx-turns occur as a recently described three residue feature named an asx-nest.

  20. Mimicry by asx- and ST-turns of the four main types of β-turn in proteins

    Science.gov (United States)

    Duddy, William J.; Nissink, J. Willem M.; Allen, Frank H.; Milner-White, E. James

    2004-01-01

    Hydrogen-bonded β-turns in proteins occur in four categories: type I (the most common), type II, type II’, and type I’. Asx-turns resemble β-turns, in that both have an NH. . .OC hydrogen bond forming a ring of 10 atoms. Serine and threonine side chains also commonly form hydrogen-bonded turns, here called ST-turns. Asx-turns and ST-turns can be categorized into four classes, based on side chain rotamers and the conformation of the central turn residue, which are geometrically equivalent to the four types of β-turns. We propose asx- and ST-turns be named using the type I, II, I’, and II’ β-turn nomenclature. Using this, the frequency of occurrence of both asx- and ST-turns is: type II’ > type I > type II > type I’, whereas for β-turns it is type I > type II > type I’ > type II’. Almost all type II asx-turns occur as a recently described three residue feature named an asx-nest. PMID:15459339

  1. Predicting turns in proteins with a unified model.

    Directory of Open Access Journals (Sweden)

    Qi Song

    Full Text Available MOTIVATION: Turns are a critical element of the structure of a protein; turns play a crucial role in loops, folds, and interactions. Current prediction methods are well developed for the prediction of individual turn types, including α-turn, β-turn, and γ-turn, etc. However, for further protein structure and function prediction it is necessary to develop a uniform model that can accurately predict all types of turns simultaneously. RESULTS: In this study, we present a novel approach, TurnP, which offers the ability to investigate all the turns in a protein based on a unified model. The main characteristics of TurnP are: (i using newly exploited features of structural evolution information (secondary structure and shape string of protein based on structure homologies, (ii considering all types of turns in a unified model, and (iii practical capability of accurate prediction of all turns simultaneously for a query. TurnP utilizes predicted secondary structures and predicted shape strings, both of which have greater accuracy, based on innovative technologies which were both developed by our group. Then, sequence and structural evolution features, which are profile of sequence, profile of secondary structures and profile of shape strings are generated by sequence and structure alignment. When TurnP was validated on a non-redundant dataset (4,107 entries by five-fold cross-validation, we achieved an accuracy of 88.8% and a sensitivity of 71.8%, which exceeded the most state-of-the-art predictors of certain type of turn. Newly determined sequences, the EVA and CASP9 datasets were used as independent tests and the results we achieved were outstanding for turn predictions and confirmed the good performance of TurnP for practical applications.

  2. Turn-off failure in multi-finger SOI-LIGBT used for single chip inverter ICs

    Science.gov (United States)

    Zhang, Long; Zhu, Jing; Zhao, Minna; Huang, Xuequan; Chen, Jiajun; Sun, Weifeng; Ding, Desheng

    2017-11-01

    In this paper, the clamped inductive turn-off failure of the Silicon-on-Insulator Lateral Insulated Gate Bipolar Transistor (SOI-LIGBT) with multiple fingers under high-voltage and high-current conditions is investigated. First, the measured turn-off waveforms combining with the on-state I-V characteristics of the failed device are discussed to distinguish the probable cause of the failure. Then, two-dimensional (2-D) electrothermal simulations are performed to reproduce the failure by using Sentaurus TCAD. The failure is originated from an inhomogeneous depletion behavior among the paralleled fingers during the turn-off, which gives rise to the non-uniform current-sharing and the subsequent current crowding in single finger. As a result, the latch-up of the device takes place. The simulation indicates that the current crowding is formed mainly through an internal path in the silicon. In order to verify the failure mechanism, an improved device with deep-oxide trenches arranged between the adjacent fingers is fabricated. The measured results demonstrate that no failure occurs when the improved device turns off under high-voltage and high-current conditions.

  3. Voltage controlled spintronics device for logic applications.

    Energy Technology Data Exchange (ETDEWEB)

    Bader, S. D.; You, C.-Y.

    1999-09-03

    We consider logic device concepts based on our previously proposed spintronics device element whose magnetization orientation is controlled by application of a bias voltage instead of a magnetic field. The basic building block is the voltage-controlled rotation (VCR) element that consists of a four-layer structure--two ferromagnetic layers separated by both nanometer-thick insulator and metallic spacer layers. The interlayer exchange coupling between the two ferromagnetic layers oscillates as a function of applied voltage. We illustrate transistor-like concepts and re-programmable logic gates based on VCR elements.

  4. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  5. Analysis of NSTX TF Joint Voltage Measurements

    International Nuclear Information System (INIS)

    Woolley R

    2005-01-01

    This report presents findings of analyses of recorded current and voltage data associated with 72 electrical joints operating at high current and high mechanical stress. The analysis goal was to characterize the mechanical behavior of each joint and thus evaluate its mechanical supports. The joints are part of the toroidal field (TF) magnet system of the National Spherical Torus Experiment (NSTX) pulsed plasma device operating at the Princeton Plasma Physics Laboratory (PPPL). Since there is not sufficient space near the joints for much traditional mechanical instrumentation, small voltage probes were installed on each joint and their voltage monitoring waveforms have been recorded on sampling digitizers during each NSTX ''shot''

  6. Fully Coupled Michigan MHD - Rice Convection Model for a Northward Turning

    Science.gov (United States)

    de Zeeuw, D.; Sazykin, S.; Wolf, R.; Gombosi, T.; Powell, K.

    2003-04-01

    The Rice Convection Model (RCM) has been successfully coupled to the Michigan MHD model (BATSRUS). This fully coupled code allows us to self-consistently simulate the physics in the inner and outer magnetosphere. Results will be presented for a fully coupled-code run for idealized inputs, steady Southward IMF followed by a Northward turning of the IMF. Discussion will include details of the coupling and choices that can be made for different types of coupling. Analysis will include region-2 currents, shielding of the inner magnetosphere, polar cap potential drop, partial and symmetric ring currents, pressure distribution, magnetic field inflation, and distribution of pVegamma.

  7. Political Competition and Polarization

    DEFF Research Database (Denmark)

    Schultz, Christian

    This paper considers political competition and the consequences of political polarization when parties are better informed about how the economy functions than voters are. Specifically, parties know the cost producing a public good, voters do not. An incumbent's choice of policy acts like a signa...... for costs before an upcoming election. It is shown that the more polarized the political parties the more distorted the incumbent's policy choice.......This paper considers political competition and the consequences of political polarization when parties are better informed about how the economy functions than voters are. Specifically, parties know the cost producing a public good, voters do not. An incumbent's choice of policy acts like a signal...

  8. Physics of polarized targets

    CERN Document Server

    Niinikoski, Tapio

    2014-01-01

    For developing, building and operating solid polarized targets we need to understand several fields of physics that have seen sub stantial advances during the last 50 years. W e shall briefly review a selection of those that are important today. These are: 1) quantum statistical methods to describe saturation and relaxation in magnetic resonance; 2) equal spin temperature model for dy namic nuclear polarization; 3 ) weak saturation during NMR polarization measurement; 4 ) refrigeration using the quantum fluid properties of helium isotopes. These, combined with superconducting magnet technologies, permit today to reach nearly complete pola rization of almost any nuclear spins. Targets can be operated in frozen spin mode in rather low and inhomogeneous field of any orientation, and in DNP mode in beams of high intensity. Beyond such experiments of nuclear and particle physics, applications a re also emerging in macromolecular chemistry and in magnetic resonance imaging. This talk is a tribute to Michel Borghini...

  9. No More Polarization, Please!

    DEFF Research Database (Denmark)

    Hansen, Mia Reinholt

    The organizational science literature on motivation has for long been polarized into two main positions; the organizational economic position focusing on extrinsic motivation and the organizational behavior position emphasizing intrinsic motivation. With the rise of the knowledge economy...... and the increasing levels of complexities it entails, such polarization is not fruitful in the attempt to explain motivation of organizational members. This paper claims that a more nuanced perspective on motivation, acknowledging the co-existence of intrinsic and extrinsic motivation, the possible interaction...... between the two as well as different types of motivations filling in the gap between the two polar types, is urgently needed in the organizational science literature. By drawing on the research on intrinsic and extrinsic motivation conducted in social psychology and combining this with contributions from...

  10. A lunar polar expedition

    Science.gov (United States)

    Dowling, Richard; Staehle, Robert L.; Svitek, Tomas

    1992-09-01

    Advanced exploration and development in harsh environments require mastery of basic human survival skill. Expeditions into the lethal climates of Earth's polar regions offer useful lessons for tommorrow's lunar pioneers. In Arctic and Antarctic exploration, 'wintering over' was a crucial milestone. The ability to establish a supply base and survive months of polar cold and darkness made extensive travel and exploration possible. Because of the possibility of near-constant solar illumination, the lunar polar regions, unlike Earth's may offer the most hospitable site for habitation. The World Space Foundation is examining a scenario for establishing a five-person expeditionary team on the lunar north pole for one year. This paper is a status report on a point design addressing site selection, transportation, power, and life support requirements.

  11. POLARIZED NEUTRONS IN RHIC

    Energy Technology Data Exchange (ETDEWEB)

    COURANT,E.D.

    1998-04-27

    There does not appear to be any obvious way to accelerate neutrons, polarized or otherwise, to high energies by themselves. To investigate the behavior of polarized neutrons the authors therefore have to obtain them by accelerating them as components of heavier nuclei, and then sorting out the contribution of the neutrons in the analysis of the reactions produced by the heavy ion beams. The best neutron carriers for this purpose are probably {sup 3}He nuclei and deuterons. A polarized deuteron is primarily a combination of a proton and a neutron with their spins pointing in the same direction; in the {sup 3}He nucleus the spins of the two protons are opposite and the net spin (and magnetic moment) is almost the same as that of a free neutron. Polarized ions other than protons may be accelerated, stored and collided in a ring such as RHIC provided the techniques proposed for polarized proton operation can be adapted (or replaced by other strategies) for these ions. To accelerate polarized particles in a ring, one must make provisions for overcoming the depolarizing resonances that occur at certain energies. These resonances arise when the spin tune (ratio of spin precession frequency to orbit frequency) resonates with a component present in the horizontal field. The horizontal field oscillates with the vertical motion of the particles (due to vertical focusing); its frequency spectrum is dominated by the vertical oscillation frequency and its modulation by the periodic structure of the accelerator ring. In addition, the magnet imperfections that distort the closed orbit vertically contain all integral Fourier harmonics of the orbit frequency.

  12. Quantitative interpretation of the transition voltages in gold-poly(phenylene) thiol-gold molecular junctions

    KAUST Repository

    Wu, Kunlin

    2013-01-01

    The transition voltage of three different asymmetric Au/poly(phenylene) thiol/Au molecular junctions in which the central molecule is either benzene thiol, biphenyl thiol, or terphenyl thiol is investigated by first-principles quantum transport simulations. For all the junctions, the calculated transition voltage at positive polarity is in quantitative agreement with the experimental values and shows weak dependence on alterations of the Au-phenyl contact. When compared to the strong coupling at the Au-S contact, which dominates the alignment of various molecular orbitals with respect to the electrode Fermi level, the coupling at the Au-phenyl contact produces only a weak perturbation. Therefore, variations of the Au-phenyl contact can only have a minor influence on the transition voltage. These findings not only provide an explanation to the uniformity in the transition voltages found for π-conjugated molecules measured with different experimental methods, but also demonstrate the advantage of transition voltage spectroscopy as a tool for determining the positions of molecular levels in molecular devices. © 2013 AIP Publishing LLC.

  13. THE NEOLIBERAL TURN IN AMERICAN HEALTH CARE.

    Science.gov (United States)

    Gaffney, Adam

    2015-01-01

    Leaving millions both uninsured and underinsured, the Affordable Care Act does not create a system of universal health care in the United States. To understand its shortcomings, we have to understand it as part of a historic shift in the political economy of American health care. This "neoliberal turn" began as a reaction against the welfare state as it expanded during the New Deal and post-World War II period. What began as a movement associated with philosophers like Friedrich Hayek ultimately had a powerful impact via the attraction of powerful corporate sponsors and political supporters, and it was to historically transform American health care thought and organization. In health policy circles, for example, it can be seen in a rising emphasis on "moral hazard," overuse, and cost sharing above a concern with universalism and equity. It was likewise manifested by the corporatization of the health maintenance organization and the rise of the "consumer-driven" health care movement. By the time of the health care reform debate, the influence of corporate "stakeholders" was to prove predominant. These developments, however, must be construed as connected parts of a much larger political transformation, reflected in rising inequality and privatization, occurring both domestically and internationally.

  14. Cosmopolitan Pluralism: Beyond the Cultural Turn

    Directory of Open Access Journals (Sweden)

    Stephanie Lawson

    2011-11-01

    Full Text Available The ‘cultural turn’ has had a profound influence across the humanities and social sciences in the last few decades. In calling into question the universalist basis on which conventional methodological and normative assumptions have been based, the cultural turn has focused on the extent to which specificity and particularity underpin what we can know, how we can know it, and how this affects our being-in-the world. This has opened the way to a range of insights, from issues of pluralism and difference, both within political communities and between them, to the instability if not impossibility of foundations for knowledge. Too few studies embracing this ‘cultural turn’, however, pay more than cursory attention to the culture concept itself. This article suggests that conceptions of culture derived mainly from the discipline of anthropology dominate in political studies, including international relations, while humanist conceptions have been largely ignored or rejected. It argues further that we would do well to reconsider what humanist ideas can contribute to how ‘culture’ is both conceptualized and deployed in political thought and action, especially in countering the overparticularization of social and political phenomena that marks contemporary culturalist approaches.

  15. Now, It's Your Turn: How You Can Take Medicine Safely

    Science.gov (United States)

    ... please turn Javascript on. Feature: Taking Medicines Safely Now, It's Your Turn: How You Can Take Medicine ... a medicine. The pharmacist has filled the prescription. Now it's up to you to take the medicine ...

  16. Dark Polar Dunes

    Science.gov (United States)

    2005-01-01

    20 January 2004 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image, acquired during northern summer in December 2004, shows dark, windblown sand dunes in the north polar region of Mars. A vast sea of sand dunes nearly surrounds the north polar cap. These landforms are located near 80.3oN, 144.1oW. Light-toned features in the image are exposures of the substrate that underlies the dune field. The image covers an area about 3 km (1.9 mi) wide and is illuminated by sunlight from the lower left.

  17. Imaging with Polarized Neutrons

    Directory of Open Access Journals (Sweden)

    Nikolay Kardjilov

    2018-01-01

    Full Text Available Owing to their zero charge, neutrons are able to pass through thick layers of matter (typically several centimeters while being sensitive to magnetic fields due to their intrinsic magnetic moment. Therefore, in addition to the conventional attenuation contrast image, the magnetic field inside and around a sample can be visualized by detecting changes of polarization in a transmitted beam. The method is based on the spatially resolved measurement of the cumulative precession angles of a collimated, polarized, monochromatic neutron beam that traverses a magnetic field or sample.

  18. The polar mesosphere

    International Nuclear Information System (INIS)

    Morris, Ray; Murphy, Damian

    2008-01-01

    The mesosphere region, which lies at the edge of space, contains the coldest layer of the Earth's atmosphere, with summer temperatures as low as minus 130 °C. In this extreme environment ice aerosol layers have appeared since the dawn of industrialization—whose existence may arguably be linked to human influence—on yet another layer of the Earth's fragile atmosphere. Ground-based and space-based experiments conducted in the Arctic and Antarctic during the International Polar Year (IPY) aim to address limitations in our knowledge and to advance our understanding of thermal and dynamical processes at play in the polar mesosphere

  19. Internal polarized targets

    Energy Technology Data Exchange (ETDEWEB)

    Kinney, E.R.; Coulter, K.; Gilman, R.; Holt, R.J.; Kowalczyk, R.S.; Napolitano, J.; Potterveld, D.H.; Young, L. (Argonne National Lab., IL (USA)); Mishnev, S.I.; Nikolenko, D.M.; Popov, S.G.; Rachek, I.A.; Temnykh, A.B.; Toporkov, D.K.; Tsentalovich, E.P.; Wojtsekhowski, B.B. (AN SSSR, Novosibirsk (USSR). Inst. Yadernoj Fiziki)

    1989-01-01

    Internal polarized targets offer a number of advantages over external targets. After a brief review of the basic motivation and principles behind internal polarized targets, the technical aspects of the atomic storage cell will be discussed in particular. Sources of depolarization and the means by which their effects can be ameliorated will be described, especially depolarization by the intense magnetic fields arising from the circulating particle beam. The experience of the Argonne Novosibirsk collaboration with the use of a storage cell in a 2 GeV electron storage ring will be the focus of this technical discussion. 17 refs., 11 figs.

  20. AGS polarized H- source

    International Nuclear Information System (INIS)

    Kponou, A.; Alessi, J.G.; Sluyters, T.

    1985-01-01

    The AGS polarized H - source is now operational. During a month-long experimental physics run in July 1984, pulses equivalent to 15 μA x 300 μs (approx. 3 x 10 10 protons) were injected into the RFQ preaccelerator. Beam polarization, measured at 200 MeV, was approx. 75%. After the run, a program to increase the H - yield of the source was begun and significant progress has been made. The H - current is now frequently 20 to 30 μA. A description of the source and some details of our operating experience are given. We also briefly describe the improvement program

  1. Control model design to limit DC-link voltage during grid fault in a dfig variable speed wind turbine

    Science.gov (United States)

    Nwosu, Cajethan M.; Ogbuka, Cosmas U.; Oti, Stephen E.

    2017-08-01

    This paper presents a control model design capable of inhibiting the phenomenal rise in the DC-link voltage during grid- fault condition in a variable speed wind turbine. Against the use of power circuit protection strategies with inherent limitations in fault ride-through capability, a control circuit algorithm capable of limiting the DC-link voltage rise which in turn bears dynamics that has direct influence on the characteristics of the rotor voltage especially during grid faults is here proposed. The model results so obtained compare favorably with the simulation results as obtained in a MATLAB/SIMULINK environment. The generated model may therefore be used to predict near accurately the nature of DC-link voltage variations during fault given some factors which include speed and speed mode of operation, the value of damping resistor relative to half the product of inner loop current control bandwidth and the filter inductance.

  2. Advanced DVR with Zero-Sequence Voltage Component and Voltage Harmonic Elimination for Three-Phase Three-Wire Distribution Systems

    Directory of Open Access Journals (Sweden)

    Margo P

    2009-11-01

    Full Text Available Dynamic Voltage Restorer (DVR is a power electronics device to protect sensitive load when voltage sag occurs. Commonly, sensitive loads are electronic-based devices which generate harmonics. The magnitude and phase of compensated voltage in DVR depend on grounding system and type of fault. If the system is floating, the zero sequence components do not appear on the load side. Meanwhile, in a neutral grounded system, voltage sag is extremely affected by zero sequence components. A blocking transformer is commonly installed in series with DVR to reduce the effect of zero sequence components. This paper proposes a new DVR control scheme that is capable of eliminating the blocking transformer and reducing harmonic distortion. The system uses fuzzy polar controller to replace the conventional PI or FL controller that is commonly used. By taking into account the zero sequence components in the controller design, the effects of zero sequence components can be compensated. Simulated results show the effectiveness of the proposed DVR controller

  3. The physics of polarization

    Science.gov (United States)

    Landi Degl'Innocenti, Egidio

    This course is intended to give a description of the basic physical concepts which underlie the study and the interpretation of polarization phenomena. Apart from a brief historical introduction (Sect. 1), the course is organized in three parts. A first part (Sects. 2 - 6) covers the most relevant facts about the polarization phenomena that are typically encountered in laboratory applications and in everyday life. In Sect. 2, the modern description of polarization in terms of the Stokes parameters is recalled, whereas Sect. 3 is devoted to introduce the basic tools of laboratory polarimetry, such as the Jones calculus and the Mueller matrices. The polarization phenomena which are met in the reflection and refraction of a beam of radiation at the separation surface between two dielectrics, or between a dielectric and a metal, are recalled in Sect. 4. Finally, Sect. 5 gives an introduction to the phenomena of dichroism and of anomalous dispersion and Sect. 6 summarizes the polarization phenomena that are commonly encountered in everyday life. The second part of this course (Sects. 7-14) deals with the description, within the formalism of classical physics, of the spectro-polarimetric properties of the radiation emitted by accelerated charges. Such properties are derived by taking as starting point the Liénard and Wiechert equations that are recalled and discussed in Sect. 7 both in the general case and in the non-relativistic approximation. The results are developed to find the percentage polarization, the radiation diagram, the cross-section and the spectral characteristics of the radiation emitted in different phenomena particularly relevant from the astrophysical point of view. The emission of a linear antenna is derived in Sect. 8. The other Sections are devoted to Thomson scattering (Sect. 9), Rayleigh scattering (Sect. 10), Mie scattering (Sect. 11), bremsstrahlung radiation (Sect. 12), cyclotron radiation (Sect. 13), and synchrotron radiation (Sect. 14

  4. Polarized Proton Collisions at RHIC

    CERN Document Server

    Bai, Mei; Alekseev, Igor G; Alessi, James; Beebe-Wang, Joanne; Blaskiewicz, Michael; Bravar, Alessandro; Brennan, Joseph M; Bruno, Donald; Bunce, Gerry; Butler, John J; Cameron, Peter; Connolly, Roger; De Long, Joseph; Drees, Angelika; Fischer, Wolfram; Ganetis, George; Gardner, Chris J; Glenn, Joseph; Hayes, Thomas; Hseuh Hsiao Chaun; Huang, Haixin; Ingrassia, Peter; Iriso, Ubaldo; Laster, Jonathan S; Lee, Roger C; Luccio, Alfredo U; Luo, Yun; MacKay, William W; Makdisi, Yousef; Marr, Gregory J; Marusic, Al; McIntyre, Gary; Michnoff, Robert; Montag, Christoph; Morris, John; Nicoletti, Tony; Oddo, Peter; Oerter, Brian; Osamu, Jinnouchi; Pilat, Fulvia Caterina; Ptitsyn, Vadim; Roser, Thomas; Satogata, Todd; Smith, Kevin T; Svirida, Dima; Tepikian, Steven; Tomas, Rogelio; Trbojevic, Dejan; Tsoupas, Nicholaos; Tuozzolo, Joseph; Vetter, Kurt; Wilinski, Michelle; Zaltsman, Alex; Zelenski, Anatoli; Zeno, Keith; Zhang, S Y

    2005-01-01

    The Relativistic Heavy Ion Collider~(RHIC) provides not only collisions of ions but also collisions of polarized protons. In a circular accelerator, the polarization of polarized proton beam can be partially or fully lost when a spin depolarizing resonance is encountered. To preserve the beam polarization during acceleration, two full Siberian snakes were employed in RHIC to avoid depolarizing resonances. In 2003, polarized proton beams were accelerated to 100~GeV and collided in RHIC. Beams were brought into collisions with longitudinal polarization at the experiments STAR and PHENIX by using spin rotators. RHIC polarized proton run experience demonstrates that optimizing polarization transmission efficiency and improving luminosity performance are significant challenges. Currently, the luminosity lifetime in RHIC is limited by the beam-beam effect. The current state of RHIC polarized proton program, including its dedicated physics run in 2005 and efforts to optimize luminosity production in beam-beam limite...

  5. Nested high voltage generator/particle accelerator

    International Nuclear Information System (INIS)

    Adler, R.J.

    1992-01-01

    This patent describes a modular high voltage particle accelerator having an emission axis and an emission end, the accelerator. It comprises: a plurality of high voltage generators in nested adjacency to form a nested stack, each the generator comprising a cup-like housing having a base and a tubular sleeve extending from the base, a primary transformer winding encircling the nested stack; a secondary transformer winding between each adjacent pair of housings, magnetically linked to the primary transformer winding through the gaps; a power supply respective to each of the secondary windings converting alternating voltage from its respective secondary winding to d.c. voltage, the housings at the emission end forming a hollow throat for particle acceleration, a vacuum seal at the emission end of the throat which enables the throat to be evacuated; a particle source in the thrond power means to energize the primary transformer winding

  6. High voltage and electrical insulation engineering

    CERN Document Server

    Arora, Ravindra

    2011-01-01

    "The book is written for students as well as for teachers and researchers in the field of High Voltage and Insulation Engineering. It is based on the advance level courses conducted at TU Dresden, Germany and Indian Institute of Technology Kanpur, India. The book has a novel approach describing the fundamental concept of field dependent behavior of dielectrics subjected to high voltage. There is no other book in the field of high voltage engineering following this new approach in describing the behavior of dielectrics. The contents begin with the description of fundamental terminology in the subject of high voltage engineering. It is followed by the classification of electric fields and the techniques of field estimation. Performance of gaseous, liquid and solid dielectrics under different field conditions is described in the subsequent chapters. Separate chapters on vacuum as insulation and the lightning phenomenon are included"--

  7. High-voltage-compatible, fully depleted CCDs

    Energy Technology Data Exchange (ETDEWEB)

    Holland, Stephen E.; Bebek, Chris J.; Dawson, Kyle S.; Emes, JohnE.; Fabricius, Max H.; Fairfield, Jessaym A.; Groom, Don E.; Karcher, A.; Kolbe, William F.; Palaio, Nick P.; Roe, Natalie A.; Wang, Guobin

    2006-05-15

    We describe charge-coupled device (CCD) developmentactivities at the Lawrence Berkeley National Laboratory (LBNL).Back-illuminated CCDs fabricated on 200-300 mu m thick, fully depleted,high-resistivity silicon substrates are produced in partnership with acommercial CCD foundry.The CCDs are fully depleted by the application ofa substrate bias voltage. Spatial resolution considerations requireoperation of thick, fully depleted CCDs at high substrate bias voltages.We have developed CCDs that are compatible with substrate bias voltagesof at least 200V. This improves spatial resolution for a given thickness,and allows for full depletion of thicker CCDs than previously considered.We have demonstrated full depletion of 650-675 mu m thick CCDs, withpotential applications in direct x-ray detection. In this work we discussthe issues related to high-voltage operation of fully depleted CCDs, aswell as experimental results on high-voltage-compatible CCDs.

  8. Boeing's High Voltage Solar Tile Test Results

    Science.gov (United States)

    Reed, Brian J.; Harden, David E.; Ferguson, Dale C.; Snyder, David B.

    2002-01-01

    Real concerns of spacecraft charging and experience with solar array augmented electrostatic discharge arcs on spacecraft have minimized the use of high voltages on large solar arrays despite numerous vehicle system mass and efficiency advantages. Boeing's solar tile (patent pending) allows high voltage to be generated at the array without the mass and efficiency losses of electronic conversion. Direct drive electric propulsion and higher power payloads (lower spacecraft weight) will benefit from this design. As future power demand grows, spacecraft designers must use higher voltage to minimize transmission loss and power cable mass for very large area arrays. This paper will describe the design and discuss the successful test of Boeing's 500-Volt Solar Tile in NASA Glenn's Tenney chamber in the Space Plasma Interaction Facility. The work was sponsored by NASA's Space Solar Power Exploratory Research and Technology (SERT) Program and will result in updated high voltage solar array design guidelines being published.

  9. Voltage, Temperature, Frequency Margin Test Report

    DEFF Research Database (Denmark)

    Denver, Troelz

    1999-01-01

    The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation...

  10. Sensitivity based voltage instability alleviation using ANN

    Energy Technology Data Exchange (ETDEWEB)

    Chauhan, S. [National Inst. of Technology, Hamirpur (India). Electrical Engineering Dept.; Dave, M.P. [Indian Inst. of Technology, Delhi (India). Electrical Engineering Dept.

    2003-10-01

    Today an average transmission line is loaded more heavily than ever before and this has given rise to serious problem of voltage instability. A noble method for power system voltage instability estimation and improvement using ANN is presented. The method is based on the fact that reactive power injections at critical buses of the power system help to steer the system away from a developing voltage collapse. The location and quantum of reactive power support has been computed based on sensitivity. The sensitivity matrix is formulated by cascading the output/input sensitivity of multiplayer perceptron model with that of input features versus reactive power injections. The effectiveness of the proposed method is demonstrated on Ward-Hale 6-bus, IEEE 14-bus and IEEE 30-bus test systems. The method can be effectively used to make the system secure against voltage collapse condition in system planning and on-line operation. (author)

  11. Can undersea voltage measurements detect tsunamis?

    Digital Repository Service at National Institute of Oceanography (India)

    Manoj, C.; Kuvshinov, A.; Neetu, S.; Harinarayana, T.

    The movement of electrically conducting ocean water in the ambient geomagnetic field induces secondary electric and magnetic fields in the oceans. Ocean water transport is now routinely inferred from undersea cable voltage data. We try to answer...

  12. Selective serotonin reuptake inhibitor sertraline inhibits voltage ...

    Indian Academy of Sciences (India)

    2016-10-04

    701. South Korea. *Corresponding author (Email, parkws@kangwon.ac.kr). We examined the effects of the selective serotonin reuptake inhibitor (SSRI) sertraline on voltage-dependent K+ (Kv) channels in freshly isolated ...

  13. 14 CFR 417.209 - Malfunction turn analysis.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Malfunction turn analysis. 417.209 Section...'s turning capability using a set of turn curves. The analysis must account for: (1) All trajectory... the thrusting phases of flight. The analysis must account for trajectory time intervals between...

  14. History of Education in Canada: Historiographic "Turns" and Widening Horizons

    Science.gov (United States)

    Bruno-Jofré, Rosa

    2014-01-01

    This paper explores major historiographic "turns" in history of education with a focus, although not exclusively, on English-speaking Canada. It addresses the transformative intellectual impact of the turn toward social history on the history of education, the impact of cultural history and the linguistic turn, the reception of Michel…

  15. Turn Openings in Academic Talk: Where Goals and Roles Intersect

    Science.gov (United States)

    Evison, Jane

    2013-01-01

    This study uses Corpus Linguistic (CL) techniques to explore multiple turn openings in conjunction with comparative measures of turn-initial priming (the proportion of occurrences of a form that are turn-initial). Using a benchmark corpus of casual conversation as a point of comparison, six frequent items which have a particularly strong affinity…

  16. First turn simulations in the cooler synchrotron COSY

    International Nuclear Information System (INIS)

    Dinev, D.

    1991-07-01

    This paper is devoted to the first turn correction and related problems in particle accelerators of synchrotron type. The paper consists of two parts. The first part is a survey of the existing methods for first turn steering. The second part is entirely devoted to the first turn in the cooler synchrotron COSY which is under assembling in KFA-Julich, Germany. (orig.)

  17. Horizontal bridges in polar dielectric liquids

    Science.gov (United States)

    Woisetschläger, Jakob; Wexler, Adam D.; Holler, Gert; Eisenhut, Mathias; Gatterer, Karl; Fuchs, Elmar C.

    2012-01-01

    When a high-voltage direct-current is applied to two beakers filled with polar liquid dielectrica like water or methanol, a horizontal bridge forms between the two beakers. By repeating a version of Pellat's experiment, it is shown that a horizontal bridge is stable by the action of electrohydrodynamic pressure. Thus, the static and dynamic properties of the phenomenon called a `floating water bridge' can be explained by the gradient of Maxwell pressure, replenishing the liquid within the bridge against any drainage mechanism. It is also shown that a number of liquids can form stable and long horizontal bridges. The stability of such a connection, and the asymmetry in mass flow through such bridges caused by the formation of ion clouds in the vicinity of the electrodes, is also discussed by two further experiments.

  18. Model-independent analysis of the Fermilab Tevatron turn-by-turn beam position monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Petrenko, A.V.; /Novosibirsk, IYF; Valishev, A.A.; Lebedev, V.A.; /Fermilab

    2011-09-01

    Coherent transverse beam oscillations in the Tevatron were analyzed with the model-independent analysis (MIA) technique. This allowed one to obtain the model-independent values of coupled betatron amplitudes, phase advances, and dispersion function around the ring from a single dipole kick measurement. In order to solve the MIA mode mixing problem which limits the accuracy of determination of the optical functions, we have developed a new technique of rotational MIA mode untangling. The basic idea is to treat each beam position monitor (BPM) as two BPMs separated in a ring by exactly one turn. This leads to a simple criterion of MIA mode separation: the betatron phase advance between any BPM and its counterpart shifted by one turn should be equal to the betatron tune and therefore should not depend on the BPM position in the ring. Furthermore, we describe a MIA-based technique to locate vibrating magnets in a storage ring.

  19. Detecting Faults In High-Voltage Transformers

    Science.gov (United States)

    Blow, Raymond K.

    1988-01-01

    Simple fixture quickly shows whether high-voltage transformer has excessive voids in dielectric materials and whether high-voltage lead wires too close to transformer case. Fixture is "go/no-go" indicator; corona appears if transformer contains such faults. Nests in wire mesh supported by cap of clear epoxy. If transformer has defects, blue glow of corona appears in mesh and is seen through cap.

  20. The North American Josephson Voltage Interlaboratory Comparison

    Energy Technology Data Exchange (ETDEWEB)

    Parks, Harold V. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Tang, Yi-hua [National Inst. of Standards and Technology (NIST), Gaithersburg, MD (United States); Reese, Paul [Bionetics Corporation, Patrick Air Force Base, Brevard County, FL (United States); Gust, Jeff [Fluke Corporation, Everett, WA (United States); Novak, James J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2013-01-23

    The ninth North American Josephson voltage standard (JVS) interlaboratory comparison (ILC) at 10 V was completed in 2011. An on-site comparison was conducted between the National Institute of Standards and Technology compact JVS and the pivot laboratory system. A set of four traveling Zener voltage standards was then shipped from the pivot laboratory to the other participants. Here, we give the results from the 2011 ILC and review recent comparisons which have used the same traveling standards and similar procedures.

  1. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F [Livermore, CA; Yee, Daniel D [Dublin, CA

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  2. Practical experience in the determination of the tube voltage using the Ardran-Crooks cassette

    International Nuclear Information System (INIS)

    Ewen, K.; Roesner, W.

    1984-01-01

    Within the framework of quality control measures in X-ray diagnostics and therapy, it is desirable to employ for the determination of tube voltage (e.g. in diagnostic X-ray equipment) methods which are as economical as possible while saving time and being simple to apply in spite of the fact that they are as highly accurate as ever possible. The absorber method described here, represented by the Ardran-Crooks cassette, possesses the advantage of low price and easy application. However, if it is operated in such a way that time is saved (assessment by the eye), it is not so accurate, whereas in accurate operation (assessment via luxmeter) it does require a relatively large amount of time. After the film has been exposed, it is necessary to estimate or measure the agreement of blackenings on one and the same film in order to determine the tube voltage. This voltage is then read off by means of a calibration curve. The error in the determination of the tube voltage via the Ardran-Crooks cassette depends on the accuracy of the calibration curve, which, in turn, depends on the number of measurements performed when producing the curve, and on the correct voltage of the standard X-ray equipment used in producing the calibration curve. In addition, assessment by eye adds a total error of 2.3% to 8%, depending on the amount of tube voltage. If the luxmeter is used instead of the eye, this additional error is less than 1% in relation to the magnitude of the tube voltage. (orig./BWU) [de

  3. Wind Power Plant Voltage Stability Evaluation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Zhang, Y. C.

    2014-09-01

    Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

  4. VKCDB: Voltage-gated potassium channel database

    Directory of Open Access Journals (Sweden)

    Gallin Warren J

    2004-01-01

    Full Text Available Abstract Background The family of voltage-gated potassium channels comprises a functionally diverse group of membrane proteins. They help maintain and regulate the potassium ion-based component of the membrane potential and are thus central to many critical physiological processes. VKCDB (Voltage-gated potassium [K] Channel DataBase is a database of structural and functional data on these channels. It is designed as a resource for research on the molecular basis of voltage-gated potassium channel function. Description Voltage-gated potassium channel sequences were identified by using BLASTP to search GENBANK and SWISSPROT. Annotations for all voltage-gated potassium channels were selectively parsed and integrated into VKCDB. Electrophysiological and pharmacological data for the channels were collected from published journal articles. Transmembrane domain predictions by TMHMM and PHD are included for each VKCDB entry. Multiple sequence alignments of conserved domains of channels of the four Kv families and the KCNQ family are also included. Currently VKCDB contains 346 channel entries. It can be browsed and searched using a set of functionally relevant categories. Protein sequences can also be searched using a local BLAST engine. Conclusions VKCDB is a resource for comparative studies of voltage-gated potassium channels. The methods used to construct VKCDB are general; they can be used to create specialized databases for other protein families. VKCDB is accessible at http://vkcdb.biology.ualberta.ca.

  5. Lobbying and political polarization

    OpenAIRE

    Ursprung, Heinrich W.

    2002-01-01

    Standard spatial models of political competition give rise to equilibria in which the competing political parties or candidates converge to a common position. In this paper I show how political polarization can be generated in models that focus on the nexus between pre-election interest group lobbying and electoral competition.

  6. Fluorescence confocal polarizing microscopy

    Indian Academy of Sciences (India)

    Much of the modern understanding of orientational order in liquid crystals (LCs) is based on polarizing microscopy (PM). A PM image bears only two-dimensional (2D) information, integrating the 3D pattern of optical birefringence over the path of light. Recently, we proposed a technique to image 3D director patterns by ...

  7. Polarization of Bremsstrahlung

    International Nuclear Information System (INIS)

    Miller, J.

    1957-01-01

    The numerical results for the polarization of Bremsstrahlung are presented. The multiple scattering of electrons in the target is taken into account. The angular-and photon energy dependences are seen on the curves for an incident 25 MeV electron energy. (Author) [fr

  8. DESY: HERA polarization

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The new HERA electron-proton collider at DESY in Hamburg achieved the first luminosity for electron-proton collisions on 19 October last year. Only one month later, on 20 November, HERA passed another important milestone with the observation of transverse electron polarization

  9. Titan Polar Landscape Evolution

    Science.gov (United States)

    Moore, Jeffrey M.

    2016-01-01

    With the ongoing Cassini-era observations and studies of Titan it is clear that the intensity and distribution of surface processes (particularly fluvial erosion by methane and Aeolian transport) has changed through time. Currently however, alternate hypotheses substantially differ among specific scenarios with respect to the effects of atmospheric evolution, seasonal changes, and endogenic processes. We have studied the evolution of Titan's polar region through a combination of analysis of imaging, elevation data, and geomorphic mapping, spatially explicit simulations of landform evolution, and quantitative comparison of the simulated landscapes with corresponding Titan morphology. We have quantitatively evaluated alternate scenarios for the landform evolution of Titan's polar terrain. The investigations have been guided by recent geomorphic mapping and topographic characterization of the polar regions that are used to frame hypotheses of process interactions, which have been evaluated using simulation modeling. Topographic information about Titan's polar region is be based on SAR-Topography and altimetry archived on PDS, SAR-based stereo radar-grammetry, radar-sounding lake depth measurements, and superposition relationships between geomorphologic map units, which we will use to create a generalized topographic map.

  10. Graphics of polar figure

    International Nuclear Information System (INIS)

    Macias B, L.R.

    1991-11-01

    The objective of this work, is that starting from a data file coming from a spectra that has been softened, and of the one that have been generated its coordinates to project it in stereographic form, to create the corresponding polar figure making use of the Cyber computer of the ININ by means of the GRAPHOS package. This work only requires a Beta, Fi and Intensity (I) enter data file. It starts of the existence of a softened spectra of which have been generated already with these data, making use of some language that in this case was FORTRAN for the Cyber computer, a program is generated supported in the Graphos package that allows starting of a reading of the Beta, Fi, I file, to generate the points in a stereographic projection and that it culminates with the graph of the corresponding polar figure. The program will request the pertinent information that is wanted to capture in the polar figure just as: date, name of the enter file, indexes of the polar figure, number of levels, radio of the stereographic projection (cms.), crystalline system to which belongs the sample, name the neuter graph file by create and to add the own general data. (Author)

  11. Kinetics deformation of current-voltage characteristics of the varistor oxide structures due to overcharging of the localized states

    Directory of Open Access Journals (Sweden)

    Tonkoshkur A. S.

    2014-12-01

    Full Text Available Prolonged exposure of zinc oxide varistors to the electrical load leads to current-voltage characteristics (CVC deformation, which is associated with a change in the height and width of the intergranular barriers, which are main structural element of the varistors. Polarization phenomena in zinc oxide ceramics are studied in a number of works, but those are mainly limited to the study of the physics of the CVC deformation process and to determining the parameters of localized electronic states involved in this process. This paper presents the results on the simulation of the deformation of pulse CVC of a separate intergranular potential barrier at transient polarization/depolarization, associated with recharging of surface electronic states (SES, which cause this barrier. It is found that at high density of SES their degree of electron filling is small and the effect of DC voltage leads to a shift of pulse current-voltage characteristics into the region of small currents. Conversely, the low density SES are almost completely filled with electrons, and after crystallite polarization CVC is shifted to high currents. Experimental studies have confirmed the possibility of applying the discovered laws to ceramic varistor structures. The proposed model allows interpreting the «anomalous» effects (such as increase in the classification voltage and reduction of active losses power observed during the varistors accelerated aging test.

  12. Turn-Based War Chess Model and Its Search Algorithm per Turn

    Directory of Open Access Journals (Sweden)

    Hai Nan

    2016-01-01

    Full Text Available War chess gaming has so far received insufficient attention but is a significant component of turn-based strategy games (TBS and is studied in this paper. First, a common game model is proposed through various existing war chess types. Based on the model, we propose a theory frame involving combinational optimization on the one hand and game tree search on the other hand. We also discuss a key problem, namely, that the number of the branching factors of each turn in the game tree is huge. Then, we propose two algorithms for searching in one turn to solve the problem: (1 enumeration by order; (2 enumeration by recursion. The main difference between these two is the permutation method used: the former uses the dictionary sequence method, while the latter uses the recursive permutation method. Finally, we prove that both of these algorithms are optimal, and we analyze the difference between their efficiencies. An important factor is the total time taken for the unit to expand until it achieves its reachable position. The factor, which is the total number of expansions that each unit makes in its reachable position, is set. The conclusion proposed is in terms of this factor: Enumeration by recursion is better than enumeration by order in all situations.

  13. Breaking New Ground with High Resolution Turn-By-Turn BPMs at the ESRF

    CERN Document Server

    Farvacque, L; Scheidt, K

    2001-01-01

    This High-Resolution, Turn-by-Turn BPM system is a low-cost extension to the existing BPM system, based on the RF-multiplexing concept, used for slow Closed-Orbit measurements. With this extension Beam Position measurements in both planes, at all (224) BPMs in the 844 m ESRF Storage Ring, for up to 2048 Orbit Turns with 1 μm resolution are performed. The data acquisition is synchronised to a single, flat 1 μs, transverse deflection kick to the 1μs beamfill in the 2.8μs revolution period. The high quality of this synchronisation, together with the good reproducibility of the deflection kick and the overall stability of the Closed Orbit beam allows to repeat the kick and acquisition in many cycles. The subsequent averaging of the data obtained in these cycles yields the 1um resolution. The latter allows lattice measurements with high precision such as the localisation of very small focussing errors and modulation in Beta values and phase advances. It also finds an unique ...

  14. A highly efficient type I β-turn mimetic simulating an Asx-Pro-turn-like structure.

    Science.gov (United States)

    Pinsker, Andrea; Einsiedel, Jürgen; Härterich, Steffen; Waibel, Reiner; Gmeiner, Peter

    2011-07-01

    Asx-Pro-turns have been identified with high frequency in protein structures nucleating type I β-turns. By bridging the amino acid side chain in position i with a nitrogen substituent in position i+2 by ring-closing olefin metathesis (RCM), peptide mimetics of type 1 could be developed. NMR based conformational investigations indicated a stable intramolecular H-bond constraining a U-turn conformation that was predicted to simulate a type I β-turn.

  15. Understanding and Prevention of Transient Voltages and Dielectric Breakdown in High Voltage Battery Systems

    Science.gov (United States)

    2017-07-31

    From - To) 07/31/2017 Final 4/1/2016 - 5/31/2017 4. TITLE AND SUBTITLE Sa. CONTRACT NUMBER Understanding and Prevention of Transient Voltages and...and Prevention of Transient Voltages and Dielectric Breakdown in High Voltage Battery Systems Submitted to: Mr. Donald Hoffman donald.hoffman...the next hurdle was to begin to evaluate the suppression topologies ability to prevent transients. IV.a. TVS Diodes TVS diodes were evaluated from

  16. Research of a fractional-turn ratio saturable pulse transformer and its application in a microsecond-range pulse modulator

    Science.gov (United States)

    Chen, Rong; Yang, Jianhua; Cheng, Xinbing; Pan, Zilong

    2017-06-01

    As a combination device for a step-up pulse transformer and a magnetic switch, the saturable pulse transformer is widely used in pulsed-power and plasma technology. A fractional-turn ratio saturable pulse transformer is constructed and analyzed in this paper. Preliminary experimental results show that if the primary energy storage capacitors are charged to 300 V, an output voltage of about 19 kV can be obtained across the capacitor connected to the secondary windings of a fractional-turn ratio saturable pulse transformer. Theoretical and experimental results reveal that this kind of pulse transformer is not only able to integrate a step-up transformer and a magnetic switch into one device, but can also lower the saturable inductance of its secondary windings, thus leading to the relatively high step-up ratio of the pulse transformer. Meanwhile, the application of the fractional-turn ratio saturable pulse transformer in a μs range pulse modulator as a voltage step-up device and main switch is also included in this paper. The demonstrated experiments display that an output voltage with an amplitude of about 29 kV, and a 1.6 μs pulse width can be obtained across a 3500 Ω resistive load, based on a pulse modulator, if the primary energy storage capacitors are charged to 300 V. This compact fractional-turn ratio saturable pulse transformer can be applied in many other fields such as surface treatment, corona plasma generation and dielectric barrier discharge.

  17. Characteristics of volume polarization holography with linear polarization light

    Science.gov (United States)

    Zang, Jinliang; Wu, An'an; Liu, Ying; Wang, Jue; Lin, Xiao; Tan, Xiaodi; Shimura, Tsutomu; Kuroda, Kazuo

    2015-10-01

    Volume polarization holographic recording in phenanthrenequinone-doped poly(methyl methacrylate) (PQ-PMMA) photopolymer with linear polarized light is obtained. The characteristics of the volume polarization hologram are experimentally investigated. It is found that beyond the paraxial approximation the polarization states of the holographic reconstruction light are generally different from the signal light. Based on vector wave theoretical analyses and material properties, the special exposure condition for correctly holographic reconstruction is obtained and experimentally demonstrated.

  18. A Study of the use of a Crystal as a `Quarter-Wave Plate' to Produce High Energy Circularly Polarized Photons

    CERN Multimedia

    Kononets, I

    2002-01-01

    %NA59 %title\\\\ \\\\We present a proposal to study the use of a crystal as a `quarter-wave plate' to produce high energy circularly polarized photons, starting from unpolarized electrons. The intention is to generate linearly polarized photons by letting electrons pass a crystalline target, where they interact coherently with the lattice nuclei. The photon polarization is subsequently turned into circular polarization after passing another crystal, which acts as a `quarter-wave plate'.

  19. and γγ-turns in proteins revisited: A new set of amino acid turn-type de

    Indian Academy of Sciences (India)

    mine, valine, glutamic acid and alanine has decreased for β-turns. Certain new amino acid preferences were observed for both turn types and individual amino acids showed turn-type dependent positional preferences. The rationale for new amino acid preferences are discussed in the light of hydrogen bonds and other.

  20. and γγ-turns in proteins revisited: A new set of amino acid turn-type de

    Indian Academy of Sciences (India)

    cent Protein Data Bank has nearly doubled and the number of γ-turns in a representative set of 320 proteins has in- creased over seven times since the previous analysis. β-turns (7153) and γ-turns (911) extracted from these proteins were used to derive a revised set of type-dependent amino acid positional preferences and ...

  1. Mitigation of Voltage Dip and Voltage Flickering by Multilevel D-STATCOM

    Directory of Open Access Journals (Sweden)

    M. S. Ballal

    2012-01-01

    Full Text Available The basic power quality problems in the distribution network are voltage sag (dip, voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.

  2. Control and Testing of a Dynamic Voltage Restorer (DVR) at Medium Voltage Level

    DEFF Research Database (Denmark)

    Nielsen, John Godsk; Newman, Michael; Nielsen, Hans Ove

    2004-01-01

    The dynamic voltage restorer (DVR) has become popular as a cost effective solution for the protection of sensitive loads from voltage sags. Implementations of the DVR have been proposed at both a low voltage (LV) level, as well as a medium voltage (MV) level; and give an opportunity to protect high...... power sensitive loads from voltage sags. This paper reports practical test results obtained on a medium voltage (10 kV) level using a DVR at a Distribution test facility in Kyndby, Denmark. The DVR was designed to protect a 400-kVA load from a 0.5-p.u. maximum voltage sag. The reported DVR verifies...... duration voltage sags were created using a controllable LV breaker fed by a 630 kVA Distribution transformer placed upstream of the sensitive load. The fault currents in excess of 12 kA were designed and created to obtain the required voltage sags. It is concluded the DVR works well in all operating...

  3. Analysis of Voltage Support by Electric Vehicles and Photovoltaic in a Real Danish Low Voltage Network

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Juul Møller, René

    2014-01-01

    of incorporating electric vehicles (EVs) in a low voltage distribution network with high penetration of photovoltaic installations (PVs), and focuses on analysing potential voltage support functions from EVs and PVs. In addition, the paper evaluates the benefits that reactive power control may provide...... with addressing the issues regarding voltage control at the expense of increased loading. Analysed real Danish low voltage network has been modelled in Matlab SimPowerSystems and is based on consumption and PV production data measured individually for number of households....

  4. Voltage scheduling for low power/energy

    Science.gov (United States)

    Manzak, Ali

    2001-07-01

    Power considerations have become an increasingly dominant factor in the design of both portable and desk-top systems. An effective way to reduce power consumption is to lower the supply voltage since voltage is quadratically related to power. This dissertation considers the problem of lowering the supply voltage at (i) the system level and at (ii) the behavioral level. At the system level, the voltage of the variable voltage processor is dynamically changed with the work load. Processors with limited sized buffers as well as those with very large buffers are considered. Given the task arrival times, deadline times, execution times, periods and switching activities, task scheduling algorithms that minimize energy or peak power are developed for the processors equipped with very large buffers. A relation between the operating voltages of the tasks for minimum energy/power is determined using the Lagrange multiplier method, and an iterative algorithm that utilizes this relation is developed. Experimental results show that the voltage assignment obtained by the proposed algorithm is very close (0.1% error) to that of the optimal energy assignment and the optimal peak power (1% error) assignment. Next, on-line and off-fine minimum energy task scheduling algorithms are developed for processors with limited sized buffers. These algorithms have polynomial time complexity and present optimal (off-line) and close-to-optimal (on-line) solutions. A procedure to calculate the minimum buffer size given information about the size of the task (maximum, minimum), execution time (best case, worst case) and deadlines is also presented. At the behavioral level, resources operating at multiple voltages are used to minimize power while maintaining the throughput. Such a scheme has the advantage of allowing modules on the critical paths to be assigned to the highest voltage levels (thus meeting the required timing constraints) while allowing modules on non-critical paths to be assigned

  5. Transient charging and discharging of spin-polarized electrons in a quantum dot

    DEFF Research Database (Denmark)

    De Souza, Fabricio; Leao, S.A.; Gester, R. M.

    2007-01-01

    We study spin-polarized transient transport in a quantum dot coupled to two ferromagnetic leads subjected to a rectangular bias voltage pulse. Time-dependent spin-resolved currents, occupations, spin accumulation, and tunneling magnetoresistance TMR are calculated using both nonequilibrium Green...

  6. Optimal voltage stimulation parameters for network-mediated responses in wild type and rd10 mouse retinal ganglion cells

    Science.gov (United States)

    Jalligampala, Archana; Sekhar, Sudarshan; Zrenner, Eberhart; Rathbun, Daniel L.

    2017-04-01

    To further improve the quality of visual percepts elicited by microelectronic retinal prosthetics, substantial efforts have been made to understand how retinal neurons respond to electrical stimulation. It is generally assumed that a sufficiently strong stimulus will recruit most retinal neurons. However, recent evidence has shown that the responses of some retinal neurons decrease with excessively strong stimuli (a non-monotonic response function). Therefore, it is necessary to identify stimuli that can be used to activate the majority of retinal neurons even when such non-monotonic cells are part of the neuronal population. Taking these non-monotonic responses into consideration, we establish the optimal voltage stimulation parameters (amplitude, duration, and polarity) for epiretinal stimulation of network-mediated (indirect) ganglion cell responses. We recorded responses from 3958 mouse retinal ganglion cells (RGCs) in both healthy (wild type, WT) and a degenerating (rd10) mouse model of retinitis pigmentosa—using flat-mounted retina on a microelectrode array. Rectangular monophasic voltage-controlled pulses were presented with varying voltage, duration, and polarity. We found that in 4-5 weeks old rd10 mice the RGC thresholds were comparable to those of WT. There was a marked response variability among mouse RGCs. To account for this variability, we interpolated the percentage of RGCs activated at each point in the voltage-polarity-duration stimulus space, thus identifying the optimal voltage-controlled pulse (-2.4 V, 0.88 ms). The identified optimal voltage pulse can activate at least 65% of potentially responsive RGCs in both mouse strains. Furthermore, this pulse is well within the range of stimuli demonstrated to be safe and effective for retinal implant patients. Such optimized stimuli and the underlying method used to identify them support a high yield of responsive RGCs and will serve as an effective guideline for future in vitro investigations of

  7. Experiments with Fermilab polarized proton and polarized antiproton beams

    International Nuclear Information System (INIS)

    Yokosawa, A.

    1990-01-01

    We summarize activities concerning the Fermilab polarized beams. They include a brief description of the polarized-beam facility, measurements of beam polarization by polarimeters, asymmetry measurements in the π degree production at high p perpendicular and in the Λ (Σ degree), π ± , π degree production at large x F , and Δσ L (pp, bar pp) measurements. 18 refs

  8. NUCLEON POLARIZATION IN 3-BODY MODELS OF POLARIZED LI-6

    NARCIS (Netherlands)

    SCHELLINGERHOUT, NW; KOK, LP; COON, SA; ADAM, RM

    1993-01-01

    Just as He-3 --> can be approximately characterized as a polarized neutron target, polarized Li-6D has been advocated as a good isoscalar nuclear target for the extraction of the polarized gluon content of the nucleon. The original argument rests upon a presumed ''alpha + deuteron'' picture of Li-6,

  9. China's nuclear industry at a turning point

    International Nuclear Information System (INIS)

    Kubota, Hideo

    2009-01-01

    The China nuclear industry is coming at a turning point since the first Chinese nuclear power plant of Qinshan No.1 was started construction 24 years ago. At the end of year 2008, there are 11 nuclear power plants in operation in China. The total power capacity of the facilities has reached to 9068MW. It resulted in 11th position next to Sweden. Despite the nuclear power was reached to 68.4 billion KWh, it makes up only 2% of the total electric generation in China. The thermal power takes 81% of the total generation, in which the power by coal fuel takes for the most part and the total generation by both natural gas and oil fuel take only as small as a few percentage. In this situation, a nuclear power plant development is being accelerated. As of July 2009, China has 15 nuclear power plants currently under construction with a total capacity of 15260MW, that is more than 24000MW together with ones currently in operation. Furthermore, my research shows that China would have a plan to build 180 new nuclear power plants of 192770MW, though the progress varies widely. The construction speed of China nuclear power plant has become increasingly high since 2008. Starting with the construction of. Ningde unit 1 (PWR, 1110MW) in Fujian Province, February 2008, they continuously started constructions for five more nuclear power plants in year 2008 alone. China still holds momentum in a nuclear power plant construction even in 2009, and continues constructing new nuclear power plants. They include a Liaoning. Hongyanhe unit 3 in March, Sanmen Zhejiang April 19 which lead a construction first in the world for the third generation nuclear power plant of AP1000 (PWR, 1250MW) developed by Westinghouse, Fuqing unit 2 (PWR, 1000MW) June 17, and Fangjiashan unit 2 (PWR, 1000MW) on 17, July. Besides, Shidaowan, Rongcheng phase I (200MW), which is a demonstration reactor of HTGR in Shandong. They even said that China would start construction for approximately 7 to 9 nuclear power

  10. Geomagnetic polarity transitions

    Science.gov (United States)

    Merrill, Ronald T.; McFadden, Phillip L.

    1999-05-01

    The top of Earth's liquid outer core is nearly 2900 km beneath Earth's surface, so we will never be able to observe it directly. This hot, dense, molten iron-rich body is continuously in motion and is the source of Earth's magnetic field. One of the most dynamic manifestations at Earth's surface of this fluid body is, perhaps, a reversal of the geomagnetic field. Unfortunately, the most recent polarity transition occurred at about 780 ka, so we have never observed a transition directly. It seems that a polarity transition spans many human lifetimes, so no human will ever witness the phenomenon in its entirety. Thus we are left with the tantalizing prospect that paleomagnetic records of polarity transitions may betray some of the secrets of the deep Earth. Certainly, if there are systematics in the reversal process and they can be documented, then this will reveal substantial information about the nature of the lowermost mantle and of the outer core. Despite their slowness on a human timescale, polarity transitions occur almost instantaneously on a geological timescale. This rapidity, together with limitations in the paleomagnetic recording process, prohibits a comprehensive description of any reversal transition both now and into the foreseeable future, which limits the questions that may at this stage be sensibly asked. The natural model for the geomagnetic field is a set of spherical harmonic components, and we are not able to obtain a reliable model for even the first few harmonic terms during a transition. Nevertheless, it is possible, in principle, to make statements about the harmonic character of a geomagnetic polarity transition without having a rigorous spherical harmonic description of one. For example, harmonic descriptions of recent geomagnetic polarity transitions that are purely zonal can be ruled out (a zonal harmonic does not change along a line of latitude). Gleaning information about transitions has proven to be difficult, but it does seem

  11. High-Voltage Power Supply With Fast Rise and Fall Times

    Science.gov (United States)

    Bearden, Douglas B.; Acker, Richard M.; Kapuslka, Robert E.

    2007-01-01

    A special-purpose high-voltage power supply can be electronically switched on and off with fast rise and fall times, respectively. The output potential is programmable from 20 to 1,250 V. An output current of 50 A can be sustained at 1,250 V. The power supply was designed specifically for electronically shuttering a microchannel plate in an x-ray detector that must operate with exposure times as short as 1 ms. The basic design of the power supply is also adaptable to other applications in which there are requirements for rapid slewing of high voltages. The power-supply circuitry (see figure) includes a preregulator, which is used to program the output at 1/30 of the desired output potential. After the desired voltage has been set, the outputs of a pulse width modulator (PWM) are enabled and used to amplify the preregulator output potential by 30. The amplification is achieved by use of two voltage doublers with a transformer that has two primary and two secondary windings. A resistor is used to limit the current by controlling the drive voltage of two field-effect transistors (FETs) during turn-on of the PWM. A pulse transformer is used to turn on four FETs to short-circuit four output capacitors when the outputs of the PWM have been disabled. The most notable aspects of the performance of the power supply are a rise time of only 80 s and a fall time of only 60 s at a load current of 50 A or less. Another notable aspect is that the application of a 0-to-5-V square wave to a shutdown pin of the PWM causes the production of a 0-to-1,250-V square wave at the output terminals.

  12. Polarized electron beams at SLAC

    International Nuclear Information System (INIS)

    Moffeit, K.C.

    1992-11-01

    SLAC has successfully accelerated high energy polarized electrons for the Stanford Linear Collider and fixed polarized nuclear target experiments. The polarized electron beams at SLAC use a gallium arsenide (GaAlAs for E-142) photon emission source to provide the beam of polarized electrons with polarization of approximately 28% (41% for E-142). While the beam emittance is reduced in the damping ring for SLC operation a system of bend magnets and superconducting solenoids preserve and orient the spin direction for maximum longitudinal polarization at the collision point. The electron polarization is monitored with a Compton scattering polarimeter, and was typically 22% at the e+e- collision point for the 1992 run. Improvements are discussed to increase the source polarization and to reduce the depolarization effects between the source and the collision point

  13. Analytical polarization calculations beyond SLIM

    International Nuclear Information System (INIS)

    Barber, D.P.

    1989-01-01

    A comparison is made between the theories of Bell and Leinaas and of Derbenev and Kondratenko for the spin polarization in electron storage rings. A calculation of polarization in HERA using the program SMILE of Mane is presented

  14. On Determinants of Political Polarization

    OpenAIRE

    Grechyna, Daryna

    2015-01-01

    Political polarization has been shown to significantly influence a country's economic performance. However, little is known about the drivers of political polarization. In this article, we aim to identify the main determinants of political polarization using Bayesian Model Averaging to overcome the problem of model uncertainty. We find that the level of trust within a country and the degree of income inequality are the most robust determinants of political polarization.

  15. Gravitational polarization tensor of thermal λφ4 theory

    Science.gov (United States)

    Nachbagauer, Herbert; Rebhan, Anton K.; Schwarz, Dominik J.

    1996-01-01

    The low-momentum structure of the gravitational polarization tensor of an ultrarelativistic plasma of scalar particles with λφ4 interactions is evaluated in a two-loop calculation up to and including order λ3/2. This turns out to require an improved perturbation theory which resums a local thermal mass term as well as nonlocal hard-thermal-loop vertices of scalar and gravitational fields.

  16. Investigation of phase-wise voltage regulator control logics for compensating voltage deviations in an experimental low voltage network

    DEFF Research Database (Denmark)

    Hu, Junjie; Zecchino, Antonio; Marinelli, Mattia

    2016-01-01

    This paper investigates the control logics of an on-load tap-changer (OLTC) transformer by means of an experimental system validation. The experimental low-voltage unbalanced system consists of a decoupled single-phase OLTC transformer, a 75-metre 16 mm2 cable, a controllable single-phase resistive...... load and an electric vehicle, which has the vehicle-to-grid function. Three control logics of the OLTC transformer are described in the study. The three control logics are classified based on their control objectives and control inputs, which include network currents and voltages, and can be measured...... either locally or remotely. To evaluate and compare the control performances of the three control logics, all the tests use the same loading profiles. The experimental results indicate that the modified line compensation control can regulate voltage in a safe band in the case of various load...

  17. Giant piezoelectric voltage coefficient in grain-oriented modified PbTiO3 material.

    Science.gov (United States)

    Yan, Yongke; Zhou, Jie E; Maurya, Deepam; Wang, Yu U; Priya, Shashank

    2016-10-11

    A rapid surge in the research on piezoelectric sensors is occurring with the arrival of the Internet of Things. Single-phase oxide piezoelectric materials with giant piezoelectric voltage coefficient (g, induced voltage under applied stress) and high Curie temperature (T c ) are crucial towards providing desired performance for sensing, especially under harsh environmental conditions. Here, we report a grain-oriented (with 95% texture) modified PbTiO 3 ceramic that has a high T c (364 °C) and an extremely large g 33 (115 × 10 -3  Vm N -1 ) in comparison with other known single-phase oxide materials. Our results reveal that self-polarization due to grain orientation along the spontaneous polarization direction plays an important role in achieving large piezoelectric response in a domain motion-confined material. The phase field simulations confirm that the large piezoelectric voltage coefficient g 33 originates from maximized piezoelectric strain coefficient d 33 and minimized dielectric permittivity ɛ 33 in [001]-textured PbTiO 3 ceramics where domain wall motions are absent.

  18. Spin-polarized spin excitation spectroscopy

    International Nuclear Information System (INIS)

    Loth, Sebastian; Lutz, Christopher P; Heinrich, Andreas J

    2010-01-01

    We report on the spin dependence of elastic and inelastic electron tunneling through transition metal atoms. Mn, Fe and Cu atoms were deposited onto a monolayer of Cu 2 N on Cu(100) and individually addressed with the probe tip of a scanning tunneling microscope. Electrons tunneling between the tip and the substrate exchange energy and spin angular momentum with the surface-bound magnetic atoms. The conservation of energy during the tunneling process results in a distinct onset threshold voltage above which the tunneling electrons create spin excitations in the Mn and Fe atoms. Here we show that the additional conservation of spin angular momentum leads to different cross-sections for spin excitations depending on the relative alignment of the surface spin and the spin of the tunneling electron. For this purpose, we developed a technique for measuring the same local spin with a spin-polarized and a non-spin-polarized tip by exchanging the last apex atom of the probe tip between different transition metal atoms. We derive a quantitative model describing the observed excitation cross-sections on the basis of an exchange scattering process.

  19. Turn me on! Using the “Internet of Things” to turn things on and off

    CSIR Research Space (South Africa)

    Butgereit, L

    2011-10-01

    Full Text Available -directional. The thing in question is automatically posting data to a location on the Internet for people to read. Bi-directional communication between people and things via the Internet is less common. This paper describes a project TurnMeOn where people... traversed numerous times in this project leading to a final conclusion step. 4 General Architecture There are three major components of the platform: ThingMemory, Beachcomber, and UrbanControl. ThingMemory supplies the web interface and a...

  20. Polarized electrogowdy spacetimes censored

    Energy Technology Data Exchange (ETDEWEB)

    Nungesser, Ernesto, E-mail: ernesto.nungesser@aei.mpg.d [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, 14476 Potsdam (Germany)

    2010-05-01

    A sketch of the proof of strong cosmic censorship is presented for a class of solutions of the Einstein-Maxwell equations, those with polarized Gowdy symmetry. A key element of the argument is the observation that by means of a suitable choice of variables the central equations in this problem can be written in a form where they are identical to the central equations for general (i.e. non-polarized) vacuum Gowdy spacetimes. Using this it is seen that the results of Ringstroem on strong cosmic censorship in the vacuum case have implications for the Einstein-Maxwell case. Working out the geometrical meaning of these analytical results leads to the main conclusion.

  1. Dispersion of breakdown voltage of liquid helium

    International Nuclear Information System (INIS)

    Ishii, Itaru; Noguchi, Takuya

    1978-01-01

    As for the electrical insulation characteristics of liquid helium, the discrepancy among the measured values by each person is very large even in the fundamental DC breakdown voltage in uniform electric field. The dispersion of experimental values obtained in the experiments by the same person is also large. Hereafter, the difference among the mean values obtained by each experimenter will be referred to as ''deviation of mean values'', and the dispersion of measured values around the mean value obtained by the same person as ''deviation around the man value''. The authors have mainly investigated on the latter experimentally. The cryostat was made of stainless steel, and the innermost helium chamber was of 500 mm I.D. and approximately 1200 mm deep. The high voltage electrode was of brass sphere of 25 mm diameter, and the low voltage electrode was of brass plate. The experiment was conducted for liquid helium boiling at 4.2 K and 1 atm, and the breakdown voltage and time lag were measured by applying the approximately square wave impulses of fast rise and long tail, ramp and DC voltages. The cause of the deviation of mean values may be the presence of impurity particles or the effect of electrode shape. As for the deviation around the mean value, the dispersion is large, and its standard deviation may amount to 10 to 20% of the man value. The dispersion is not due to the statistical time lag, but is due to parameters that vary with breakdown. (Wakatsuki, Y.)

  2. Quadratic sinusoidal analysis of voltage clamped neurons.

    Science.gov (United States)

    Magnani, Christophe; Moore, Lee E

    2011-11-01

    Nonlinear biophysical properties of individual neurons are known to play a major role in the nervous system, especially those active at subthreshold membrane potentials that integrate synaptic inputs during action potential initiation. Previous electrophysiological studies have made use of a piecewise linear characterization of voltage clamped neurons, which consists of a sequence of linear admittances computed at different voltage levels. In this paper, a fundamentally new theory is developed in two stages. First, analytical equations are derived for a multi-sinusoidal voltage clamp of a Hodgkin-Huxley type model to reveal the quadratic response at the ionic channel level. Second, the resulting behavior is generalized to a novel Hermitian neural operator, which uses an algebraic formulation capturing the entire quadratic behavior of a voltage clamped neuron. In addition, this operator can also be used for a nonlinear identification analysis directly applicable to experimental measurements. In this case, a Hermitian matrix of interactions is built with paired frequency probing measurements performed at specific harmonic and interactive output frequencies. More importantly, eigenanalysis of the neural operator provides a concise signature of the voltage dependent conductances determined by their particular distribution on the dendritic and somatic membrane regions of neurons. Finally, the theory is concretely illustrated by an analysis of an experimentally measured vestibular neuron, providing a remarkably compact description of the quadratic responses involved in the nonlinear processing underlying the control of eye position during head rotation, namely the neural integrator.

  3. PEPPo: Using a Polarized Electron Beam to Produce Polarized Positrons

    Energy Technology Data Exchange (ETDEWEB)

    Adeyemi, Adeleke H. [Hampton Univ., Hampton, VA (United States); et al.

    2015-09-01

    Polarized positron beams have been identified as either an essential or a significant ingredient for the experimental program of both the present and next generation of lepton accelerators (JLab, Super KEK B, ILC, CLIC). An experiment demonstrating a new method for producing polarized positrons has been performed at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. The PEPPo (Polarized Electrons for Polarized Positrons) concept relies on the production of polarized e⁻/e⁺ pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. PEPPo demonstrated the effective transfer of spin-polarization of an 8.2 MeV/c polarized (P~85%) electron beam to positrons produced in varying thickness tungsten production targets, and collected and measured in the range of 3.1 to 6.2 MeV/c. In comparison to other methods this technique reveals a new pathway for producing either high-energy or thermal polarized positron beams using a relatively low polarized electron beam energy (~10MeV) .This presentation will describe the PEPPo concept, the motivations of the experiment and high positron polarization achieved.

  4. Polarization induced doped transistor

    Science.gov (United States)

    Xing, Huili; Jena, Debdeep; Nomoto, Kazuki; Song, Bo; Zhu, Mingda; Hu, Zongyang

    2016-06-07

    A nitride-based field effect transistor (FET) comprises a compositionally graded and polarization induced doped p-layer underlying at least one gate contact and a compositionally graded and doped n-channel underlying a source contact. The n-channel is converted from the p-layer to the n-channel by ion implantation, a buffer underlies the doped p-layer and the n-channel, and a drain underlies the buffer.

  5. Polar bears, Ursus maritimus

    Science.gov (United States)

    Rode, Karyn D.; Stirling, Ian

    2017-01-01

    Polar bears are the largest of the eight species of bears found worldwide and are covered in a pigment-free fur giving them the appearance of being white. They are the most carnivorous of bear species consuming a high-fat diet, primarily of ice-associated seals and other marine mammals. They range throughout the circumpolar Arctic to the southernmost extent of seasonal pack ice.

  6. Polarized advanced fuel reactors

    International Nuclear Information System (INIS)

    Kulsrud, R.M.

    1987-07-01

    The d- 3 He reaction has the same spin dependence as the d-t reaction. It produces no neutrons, so that if the d-d reactivity could be reduced, it would lead to a neutron-lean reactor. The current understanding of the possible suppression of the d-d reactivity by spin polarization is discussed. The question as to whether a suppression is possible is still unresolved. Other advanced fuel reactions are briefly discussed. 11 refs

  7. On polarization in biomembranes

    DEFF Research Database (Denmark)

    Zecchi, Karis Amata

    close to physiological conditions, making these effects biologically relevant. In this work, we consider the case of asymmetric membranes which can display spontaneous polarization in the absence of a field. Close to the phase transition, we find that the membrane displays piezoelectric, flexoelectric...... on different geometries point in the direction of a flexoelectric mechanism behind current rectification in lipid bilayers. Finally, we suggest that our updated equivalent circuit should be included in the interpretation of elctrophysiological data....

  8. Multifrequency Behaviour of Polars

    Directory of Open Access Journals (Sweden)

    K. Reinsch

    2015-02-01

    Full Text Available Cataclysmic variables emit over a wide range of the electromagnetic spectrum. In this paper I will review observations of polars in relevant passbands obtained during the last decade and will discuss their diagnostical potential to access the physics of the main components within the binary systems. This will include a discussion of intrinsic source variability and the quest for simultaneous multi-frequency observations.

  9. Polar Business Design

    Directory of Open Access Journals (Sweden)

    Sébastien Caisse

    2014-02-01

    Full Text Available Polar business design aims to enable entrepreneurs, managers, consultants, researchers, and business students to better tackle model-based analysis, creation, and transformation of businesses, ventures, and, more generically, collective endeavors of any size and purpose. It is based on a systems-thinking approach that builds on a few interrelated core concepts to create holistic visual frameworks. These core concepts act as poles linked by meaningful dyads, flows, and faces arranged in geometric shapes. The article presents two such polar frameworks as key findings in an ongoing analytic autoethnography: the three-pole Value−Activity−Stakeholder (VAS triquetra and the four-pole Offer−Creation−Character−Stakeholder (OCCS tetrahedron. The VAS triquetra is a more aggregated model of collective endeavors. The OCCS tetrahedron makes a trade-off between a steeper learning curve and deeper, richer representation potential. This article discusses how to use these two frameworks as well as their limits, and explores the potential that polar business design offers for future research.

  10. Low-Voltage Consumption Coordination for Loss Minimization and Voltage Control

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for minimizing active power losses in low-voltage grids, by coordinating the consumption of electric vehicles and power generation from solar panels. We show that minimizing losses, also reduces voltage variations, and illustrate how this may be employed for increasing...

  11. Synchronised Voltage Space Vector Modulation for Three-level Inverters with Common-mode Voltage Elimination

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    A novel method of direct synchronous pulse-width modulation (PWM) is disseminated to three-level voltage source inverters with control algorithms with elimination of the common-mode voltages in three-phase drive systems with PWM. It provides smooth pulses-ratio changing and a quarter-wave symmetry...

  12. On Secondary Control Approaches for Voltage Regulation in DC Microgrids

    DEFF Research Database (Denmark)

    Peyghami, Saeed; Mokhtari, Hossein; Davari, Pooya

    2017-01-01

    regulation on the load busses within a suitable range. Therefore, in addition to compensate the voltage drop of the primary controller, it is necessary to regulate the voltage of critical loads. In this paper, a new voltage regulation strategy is proposed to regulate the voltage of Micro-Grid (MG...

  13. 30 CFR 75.813 - High-voltage longwalls; scope.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage longwalls; scope. 75.813 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.813 High-voltage longwalls; scope. Sections 75.814 through 75.822 of this...

  14. Voltage Support from Electric Vehicles in Distribution Grid

    DEFF Research Database (Denmark)

    Huang, Shaojun; Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2013-01-01

    The paper evaluates the voltage support functions from electric vehicles (EVs) on a typical Danish distribution grid with high EV penetration. In addition to the popular voltage control modes, such as voltage droop charging (low voltage level leads to low charging power) and reactive power support...

  15. Efficiency enhancement using voltage biasing for ferroelectric polarization in dye-sensitized solar cells

    Science.gov (United States)

    Kim, Sangmo; Song, Myoung Geun; Bark, Chung Wung

    2018-01-01

    Dye-sensitized solar cells (DSSCs) are one of the most promising third generation solar cells that have been extensively researched over the past decade as alternative to silicon-based solar cells, due to their low production cost and high energy-conversion efficiency. In general, a DSSC consists of a transparent electrode, a counter electrode, and an electrolyte such as dye. To achieve high power-conversion efficiency in cells, many research groups have focused their efforts on developing efficient dyes for liquid electrolytes. In this work, we report on the photovoltaic properties of DSSCs fabricated using a mixture of TiO2 with nanosized Fe-doped bismuth lanthanum titanate (nFe-BLT) powder). Firstly, nFe-BLT powders were prepared using a high-energy ball milling process and then, TiO2 and nFe-BLT powders were stoichiometrically blended. Direct current (DC) bias of 20 MV/m was applied to lab-made DSSCs. With the optimal concentration of nFe-BLT doped in the electrode, their light-to-electricity conversion efficiency could be improved by ∼64% compared with DSSCs where no DC bias was applied.

  16. Improving Low Voltage Ride Through Capability of Wind Generators Using Dynamic Voltage Restorer

    Science.gov (United States)

    Sivasankar, Gangatharan; Suresh Kumar, Velu

    2014-08-01

    The increasing wind power integration with power grid has forced the situation to improve the reliability of wind generators for stable operation. One important problem with induction generator based wind farm is its low ride through capability to the grid voltage disturbance. Any disturbance such as voltage dip may cause wind farm outages. Since wind power contribution is in predominant percentage, such outages may lead to stability problem. The proposed strategy is to use dynamic voltage controller (DVR) to compensate the voltage disturbance. The DVR provides the wind generator the ability to remain connected in grid and improve the reliability. The voltage dips due to symmetrical and unsymmetrical faults are considered for analysis. The vector control scheme is employed for fault compensation which uses software phase locked loop scheme and park dq0 transformation technique. Extensive simulation results are included to illustrate the control and operation of DVR.

  17. Determination of the cathode fall voltage in fluorescent lamps by measurement of the operating voltage

    International Nuclear Information System (INIS)

    Hilscher, A.

    2002-01-01

    A new method for the determination of the cathode fall voltage of fluorescent lamps is shown. The cathode fall voltage can be determined by measurement of the lamp operating voltage at constant lamp wall temperature, constant discharge current and variation of the electrode heating current. Commercial lamps, which do not need to be specially prepared, can be used for the measurement. The results show good correlation to other measurements of the cathode fall voltage at various discharge currents by means of capacitive coupling. The measured values of the cathode fall voltage are used for determining the minimum, target and maximum setting of the sum of the squares of the pin currents of one electrode (the so-called SOS value) as a function of the discharge current in fluorescent lamp dimming. (author)

  18. Energy Storage Options for Voltage Support in Low-Voltage Grids with High Penetration of Photovoltaic

    DEFF Research Database (Denmark)

    Marra, Francesco; Tarek Fawzy, Y.; Bülo, Thorsten

    2012-01-01

    The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need to be establis......The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need...... to be established. In the long term, these solutions should also aim to allow further more PV installed capacity, while meeting the power quality requirements. In this paper, different concepts of energy storage are proposed to ensure the voltage quality requirements in a LV grid with high PV penetration...

  19. Voltage control in active, intelligent low-voltage distribution networks; Spannungshaltung in aktiven, intelligenten Niederspannungsnetzen

    Energy Technology Data Exchange (ETDEWEB)

    Buelo, Thorsten; Mende, Denis [SMA Solar Technology AG, Niestetal (Germany); Geibel, Dominik [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany)] [and others

    2012-07-01

    This paper describes approaches for the voltage control in low-voltage distribution networks with a high share of distributed energy resources (DER). Taken into account are devices such as distribution transformers with on-load tap changer (OLTC), photovoltaic-inverters with reactive power capability and electronic voltage controllers (EVC). After a short description regarding voltage control, the devices and selected system concepts as well as the advantages and disadvantages of the different devices are described. Finally, the system-concepts are compared using the example of a real low voltage network, taking into account the possible increase of hosting capacity of the network, curtailing losses and the amount of reactive energy to be provided. (orig.)

  20. Voltage stability, bifurcation parameters and continuation methods

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, F.L. [Wisconsin Univ., Madison, WI (United States)

    1994-12-31

    This paper considers the importance of the choice of bifurcation parameter in the determination of the voltage stability limit and the maximum power load ability of a system. When the bifurcation parameter is power demand, the two limits are equivalent. However, when other types of load models and bifurcation parameters are considered, the two concepts differ. The continuation method is considered as a method for determination of voltage stability margins. Three variants of the continuation method are described: the continuation parameter is the bifurcation parameter the continuation parameter is initially the bifurcation parameter, but is free to change, and the continuation parameter is a new `arc length` parameter. Implementations of voltage stability software using continuation methods are described. (author) 23 refs., 9 figs.