WorldWideScience

Sample records for polarization ratio cpr

  1. Dispatcher instruction of chest compression-only CPR increases actual provision of bystander CPR.

    Science.gov (United States)

    Shimamoto, Tomonari; Iwami, Taku; Kitamura, Tetsuhisa; Nishiyama, Chika; Sakai, Tomohiko; Nishiuchi, Tatsuya; Hayashi, Yasuyuki; Kawamura, Takashi

    2015-11-01

    A preceding randomized controlled trial demonstrated that chest compression-only cardiopulmonary resuscitation (CPR) instruction by dispatcher was more effective to increase bystander CPR than conventional CPR instruction. However, the actual condition of implementation of each type of dispatcher instruction (chest compression-only CPR [CCCPR] or conventional CPR with rescue breathing) and provision of bystander CPR in real prehospital settings has not been sufficiently investigated. This registry prospectively enrolled patients aged =>18 years suffering an out-of-hospital cardiac arrest (OHCA) of non-traumatic causes before emergency-medical-service (EMS) arrival, who were considered as target subjects of dispatcher instruction, resuscitated by EMS personnel, and transported to medical institutions in Osaka, Japan from January 2005 through December 2012. The primary outcome measure was provision of CPR by a bystander. Multiple logistic regression analysis was used to assess factors that were potentially associated with provision of bystander CPR. Among 37,283 target subjects of dispatcher instruction, 5743 received CCCPR instruction and 13,926 received conventional CPR instruction. The proportion of CCCPR instruction increased from 5.7% in 2005 to 25.6% in 2012 (p for trend bystander CPR more frequently than conventional CPR instruction group (70.0% versus 62.1%, pbystander CPR compared with conventional CPR instruction (adjusted odds ratio 1.44, 95% CI 1.34-1.55). CCCPR dispatcher instruction among adult OHCA patients significantly increased the actual provision of bystander CPR. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Perception of CPR quality: Influence of CPR feedback, Just-in-Time CPR training and provider role.

    Science.gov (United States)

    Cheng, Adam; Overly, Frank; Kessler, David; Nadkarni, Vinay M; Lin, Yiqun; Doan, Quynh; Duff, Jonathan P; Tofil, Nancy M; Bhanji, Farhan; Adler, Mark; Charnovich, Alex; Hunt, Elizabeth A; Brown, Linda L

    2015-02-01

    Many healthcare providers rely on visual perception to guide cardiopulmonary resuscitation (CPR), but little is known about the accuracy of provider perceptions of CPR quality. We aimed to describe the difference between perceived versus measured CPR quality, and to determine the impact of provider role, real-time visual CPR feedback and Just-in-Time (JIT) CPR training on provider perceptions. We conducted secondary analyses of data collected from a prospective, multicenter, randomized trial of 324 healthcare providers who participated in a simulated cardiac arrest scenario between July 2012 and April 2014. Participants were randomized to one of four permutations of: JIT CPR training and real-time visual CPR feedback. We calculated the difference between perceived and measured quality of CPR and reported the proportion of subjects accurately estimating the quality of CPR within each study arm. Participants overestimated achieving adequate chest compression depth (mean difference range: 16.1-60.6%) and rate (range: 0.2-51%), and underestimated chest compression fraction (0.2-2.9%) across all arms. Compared to no intervention, the use of real-time feedback and JIT CPR training (alone or in combination) improved perception of depth (pCPR quality was poor for chest compression depth (0-13%), rate (5-46%) and chest compression fraction (60-63%). Perception of depth is more accurate in CPR providers versus team leaders (27.8% vs. 7.4%; p=0.043) when using real-time feedback. Healthcare providers' visual perception of CPR quality is poor. Perceptions of CPR depth are improved by using real-time visual feedback and with prior JIT CPR training. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Does Non-Targeted Community CPR Training Increase Bystander CPR Frequency?

    Science.gov (United States)

    Uber, Amy; Sadler, Richard C; Chassee, Todd; Reynolds, Joshua C

    2018-05-01

    Only 37% of out-of-hospital cardiac arrests (OHCA) receive bystander Cardiopulmonary resuscitation (CPR) in Kent County, MI. In May 2014, prehospital providers offered one-time, point-of-contact compression-only CPR training to 2,253 passersby at 7 public locations in Grand Rapids, Michigan. To assess the impact of this intervention, we compared bystander CPR frequency and clinical outcomes in regions surrounding training sites before and after the intervention, adjusting for prehospital covariates. We aimed to assess the effect of this broad, non-targeted intervention on bystander CPR frequency, type of CPR utilized, and clinical outcomes. We also tested for differences in geospatial variation of bystander CPR and clinical outcomes clustered around training sites. Retrospective, observational, before-after study of adult, EMS-treated OHCA in Kent County from January 1, 2010 to December 31, 2015. We generated a 5-kilometer radius surrounding each training site to estimate any geospatial influence that training sites might have on bystander CPR frequency in nearby OHCA cases. Chi-squared, Fisher's exact, and t-tests assessed differences in subject features. Difference-in-differences analysis with generalized estimating equation (GEE) modeling assessed bystander CPR frequency, adjusting for training site, covariates (age, sex, witnessed, shockable rhythm, public location), and clustering around training sites. Similar modeling tested for changes in bystander CPR type, return of spontaneous circulation (ROSC), survival to hospital discharge, and cerebral performance category (CPC) of 1-2 at hospital discharge. We included 899 cases before and 587 cases post-intervention. Overall, we observed no increase in the frequency of bystander CPR or favorable clinical outcomes. We did observe an increase in compression-only CPR, but this was paradoxically restricted to OHCA cases falling outside radii around training sites. In adjusted modeling, the bystander CPR training

  4. Compression-only CPR training in elementary schools and student attitude toward CPR.

    Science.gov (United States)

    Kitamura, Tetsuhisa; Nishiyama, Chika; Murakami, Yukiko; Yonezawa, Takahiro; Nakai, Shohei; Hamanishi, Masayoshi; Marukawa, Seishiro; Sakamoto, Tetsuya; Iwami, Taku

    2016-08-01

    Little is known about the effectiveness of systematic cardiopulmonary resuscitation (CPR) training for elementary school children. We introduced systematic training of chest compression-only CPR and automated external defibrillator (AED) use to elementary school students aged 10-12 years at 17 schools. The questionnaire compared student attitudes towards CPR and their knowledge about it before and after CPR training. We also evaluated parent and teacher views about CPR training in school education. The primary outcome was positive attitude, defined as "yes" and "maybe yes" on a 5 point Likert-type scale of student attitudes towards CPR.1 RESULTS: A total of 2047 elementary school students received CPR training. Of them, 1899 (92.8%) responded to the questionnaire regarding their attitude towards CPR before and after the training. Before training, 50.2% answered "yes" and 30.3% answered "maybe yes", to the question: "If someone suddenly collapses in front of you, can you do something such as check response or call emergency?" After training, their answers changed to 75.6% and 18.3% for "yes" and "maybe yes", respectively. Many of the students (72.3%, 271/370) who did not have a positive attitude before CPR training had a positive attitude after the training (P CPR (97.7%) and use an AED (98.5%). Parents (96.2%, 1173/1220) and teachers (98.3%, 56/57) answered that it was "good" and "maybe good" for children to receive the training at elementary schools. Systematic chest compression-only CPR training helped elementary school students to improve their attitude towards CPR. © 2015 Japan Pediatric Society.

  5. Child CPR

    Medline Plus

    Full Text Available ... AID, CPR and AED LIFEGUARDING Refresher Child - CPR (1:11) QUICK LINKS Home RedCross.org Purchase Course Materials Shop Our Store Contact Us Privacy Policy Terms and Conditions All rights reserved. 2011 American National Red Cross.

  6. Child CPR

    Medline Plus

    Full Text Available ... Home FIRST AID, CPR and AED LIFEGUARDING Refresher Child - CPR (1:11) QUICK LINKS Home RedCross.org Purchase Course Materials Shop Our Store Contact Us Privacy Policy Terms and Conditions All rights reserved. 2011 American National Red Cross.

  7. CPR Education before Internship

    Directory of Open Access Journals (Sweden)

    Vahid Ashoorion

    2009-02-01

    Full Text Available Background and purpose: The importance of training basic and advanced life support for undergraduates and graduated physicians are now widely recognized. Graduates of medical schools in Iran immediately get license to practice medicine without any supervision. Therefore,Clarification of the best phases for training CPR and the optimum mastery level in each phase is very important. This study is an attempt to find out the ideas of stakeholders about training CPR beforeinternship, the experience needed at the beginning of internship, the best phase for training it and the assessment method.Methods: It is a survey study designed in Isfahan University of Medical Sciences to investigate the opinions of head-nurses, interns, residents and educational directors (in ten clinical departments/wards about training CPR before internship. Respondents completed self administered anonymous questionnaires. The questionnaires’ items covered opinions of respondents about CPR as interns’ duty, level of experience; best course for training and the assessment method. Meanwhile, views of participants were compared against educational directors’ idea by Fisher exact test.Results:32 head-nurse, 285 interns, 13 resident and15 educational directors participated in the study and all agreed with CPR as interns’ duty in all clinical wards. Although, directors had different idea about level of experience for CPR to be achieved by interns, residents suggested level 3 of experience. According to the results externship is the best phase for CPR training and combination of observation and OSCE suggested as the best assessment method.Conclusion: To prepare the graduates achieving full competency in CPR performance, it is needed to implement training programs before internship. Internship is the best phase for getting expertise in CPR. Based on the results CPR considered as interns’ responsibility and medical schools should feel confidence about the competency ofinterns

  8. Assessing CPR training: The willingness of teaching credential candidates to provide CPR in a school setting.

    Science.gov (United States)

    Winkelman, Jack L; Fischbach, Ronald; Spinello, Elio F

    2009-12-01

    The study explores the anticipated willingness of teacher credential candidates at one California public university in the U.S. to perform cardiopulmonary resuscitation (CPR) or foreign body airway obstruction (FBAO) skills in a school setting. Objectives included (1) identifying reasons that credential candidates would elect or decline to perform CPR, (2) assisting schools to remediate cardiac/respiratory emergency preparedness, and (3) assessing CPR training courses to determine how they may influence teachers' willingness to perform CPR. Participants included 582 teacher credential candidates, who were 95.2% of those surveyed after completion of a health science course and CPR certification. Participants described their attitudes regarding the importance of CPR, the CPR training course, and their willingness to perform CPR in a school environment. Based upon chi-square analysis, an association was found between the willingness to perform CPR and the presence of any one concern regarding training, with 68.6% of those expressing concerns willing to perform CPR compared to 81.9% of those expressing no concerns (pteachers (76.9% vs. 43.5%, pteachers' willingness to perform CPR. Recommendations based on these findings include pedagogical changes to CPR curricula, focusing on the importance of CPR as a teacher skill and additional time for hands-on practice. Future research should include U.S. and international participants from a broader geographic area and assessment of both learning and affective outcomes.

  9. Timely bystander CPR improves outcomes despite longer EMS times.

    Science.gov (United States)

    Park, Gwan Jin; Song, Kyoung Jun; Shin, Sang Do; Lee, Kyung Won; Ahn, Ki Ok; Lee, Eui Jung; Hong, Ki Jeong; Ro, Young Sun

    2017-08-01

    This study aimed to determine the impact of bystander CPR on clinical outcomes in patients with increasing response time from collapse to EMS response. A population-based observational study was conducted in patients with witnessed out-of-hospital cardiac arrest (OHCA) of presumed cardiac etiology from 2012 to 2014. The time interval from collapse to CPR by EMS providers was categorized into quartile groups: fastest group (bystander CPR and the time interval from collapse to CPR by EMS providers. A total of 15,354 OHCAs were analyzed. Bystander CPR was performed in 8591 (56.0%). Survival to hospital discharge occurred in 1632 (10.6%) and favorable neurological outcome in 996 (6.5%). In an interaction model of bystander CPR, compared to the fastest group, adjusted odds ratios (AORs) (95% CIs) for survival to discharge were 0.89 (0.66-1.20) in the fast group, 0.76 (0.57-1.02) in the late group, and 0.52 (0.37-0.73) in the latest group. For favorable neurological outcome, AORs were 1.12 (0.77-1.62) in the fast group, 0.90 (0.62-1.30) in the late group, 0.59 (0.38-0.91) in the latest group. The survival from OHCA decreases as the ambulance response time increases. The increase in mortality and worsening neurologic outcomes appear to be mitigated in those patients who receive bystander CPR. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. CPR (For Parents)

    Science.gov (United States)

    ... brain, and other organs and restoring breathing until advanced life support can be given by health care providers. About CPR CPR (or cardiopulmonary resuscitation ) is a combination of chest compressions and rescue ...

  11. Regions With Low Rates of Bystander Cardiopulmonary Resuscitation (CPR) Have Lower Rates of CPR Training in Victoria, Australia.

    Science.gov (United States)

    Bray, Janet E; Straney, Lahn; Smith, Karen; Cartledge, Susie; Case, Rosalind; Bernard, Stephen; Finn, Judith

    2017-06-05

    Bystander cardiopulmonary resuscitation (CPR) more than doubles the chance of surviving an out-of-hospital cardiac arrest. Recent data have shown considerable regional variation in bystander CPR rates across the Australian state of Victoria. This study aims to determine whether there is associated regional variation in rates of CPR training and willingness to perform CPR in these communities. We categorized each Victorian postcode as either a low or high bystander CPR region using data on adult, bystander-witnessed, out-of-hospital cardiac arrests of presumed cardiac etiology (n=7175) from the Victorian Ambulance Cardiac Arrest Registry. We then surveyed adult Victorians (n=404) and compared CPR training data of the respondents from low and high bystander CPR regions. Of the 404 adults surveyed, 223 (55%) resided in regions with low bystander CPR. Compared with respondents from high bystander CPR regions, respondents residing in regions with low bystander CPR had lower rates of CPR training (62% versus 75%, P =0.009) and lower self-ratings for their overall knowledge of CPR (76% versus 84%, P =0.04). There were no differences between the regions in their reasons for not having undergone CPR training or in their willingness to perform CPR. Rates of survival for bystander-witnessed, out-of-hospital cardiac arrests were significantly lower in low bystander CPR regions (15.7% versus 17.0%, P CPR training and lower survival in regions with lower rates of bystander CPR in Victoria, Australia. Targeting these regions with CPR training programs may improve bystander CPR rates and out-of-hospital cardiac arrest outcomes. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  12. Hands-Only CPR

    Science.gov (United States)

    ... In Schools Training Kits RQI AHA Blended Learning & eLearning Guide AHA Instructors ECC Educational Conferences Programs CPR ... In Schools Training Kits RQI AHA Blended Learning & eLearning Guide AHA Instructors ECC Educational Conferences Programs CPR ...

  13. Barriers and Facilitators to Community CPR Education in San José, Costa Rica.

    Science.gov (United States)

    Schmid, Kristin M; Mould-Millman, Nee-Kofi; Hammes, Andrew; Kroehl, Miranda; García, Raquel Quiros; McDermott, Manrique Umaña; Lowenstein, Steven R

    2016-10-01

    Bystander cardiopulmonary resuscitation (CPR) improves survival after prehospital cardiac arrest. While community CPR training programs have been implemented across the US, little is known about their acceptability in non-US Latino populations. The purpose of this study was to identify barriers to enrolling in CPR training classes and performing CPR in San José, Costa Rica. After consulting 10 San José residents, a survey was created, pilot-tested, and distributed to a convenience sample of community members in public gathering places in San José. Questions included demographics, CPR knowledge and beliefs, prior CPR training, having a family member with heart disease, and prior witnessing of a cardiac arrest. Questions also addressed barriers to enrolling in CPR classes (cost/competing priorities). The analysis focused on two main outcomes: likelihood of registering for a CPR class and willingness to perform CPR on an adult stranger. Odds ratios and 95% CIs were calculated to test for associations between patient characteristics and these outcomes. Among 371 participants, most were male (60%) and education (OR: 1.9; 95% CI, 1.1-3.2). Believing that CPR does not work was associated with a higher likelihood of not attending a CPR class (OR: 2.4; 95% CI, 1.7-7.9). Fear of performing mouth-mouth, believing CPR is against God's will, and fear of legal risk were associated with a likelihood of not attending a CPR class and not performing CPR on a stranger (range of ORs: 2.4-3.9). Most San José residents are willing to take CPR classes and perform CPR on a stranger. To implement a community CPR program, barriers must be considered, including misgivings about CPR efficacy and legal risk. Hands-only CPR programs may alleviate hesitancy to perform mouth-to-mouth. Schmid KM , Mould-Millman NK , Hammes A , Kroehl M , Quiros García R , Umaña McDermott M , Lowenstein SR . Barriers and facilitators to community CPR education in San José, Costa Rica. Prehosp Disaster Med

  14. Shock outcome prediction before and after CPR: a comparative study of manual and automated active compression-decompression CPR.

    Science.gov (United States)

    Box, M S; Watson, J N; Addison, P S; Clegg, G R; Robertson, C E

    2008-09-01

    We report on a study designed to compare the relative efficacy of manual CPR (M-CPR) and automated mechanical CPR (ACD-CPR) provided by an active compression-decompression (ACD) device. The ECG signals of out-of-hospital cardiac arrest patients of cardiac aetiology were analysed just prior to, and immediately after, cardiopulmonary resuscitation (CPR) to assess the likelihood of successful defibrillation at these time points. The cardioversion outcome prediction (COP) measure previously developed by our group was used to quantify the probability of return of spontaneous circulation (ROSC) after counter-shock and was used as a measure of the efficacy of CPR. An initial validation study using COP to predict shock outcome from the patient data set resulted in a performance of 60% specificity achieved at 100% sensitivity on a blind test of the data. This is comparable with previous studies and provided confidence in the robustness of the technique across hardware platforms. Significantly, the COP marker also displayed an ability to stratify according to outcomes: asystole, ventricular fibrillation (VF), pulseless electrical activity (PEA), normal sinus rhythm (NSR). We then used the validated COP marker to analyse the ECG data record just prior to and immediately after the chest compression segments. This was initially performed for 87 CPR segments where VF was both the pre- and post-CPR waveform. An increase in the mean COP values was found for both CPR types. A signed rank sum test found the increase due to manual CPR not to be significant (p>0.05) whereas the automated CPR was found to be significant (pCPR (1.26, p=0.024) than for the manual CPR (0.99, p=0.124). These results indicate that the application of CPR does indeed provide beneficial preparation of the heart prior to defibrillation therapy whether manual or automated CPR is applied. The COP marker shows promise as a definitive, quantitative determinant of the immediate positive effect of both types of CPR

  15. Interruptions in Chest Compressions by Surf Lifeguards: A Comparison of Face-mask Ventilation in Over-the-head CPR vs Standard CPR

    DEFF Research Database (Denmark)

    Nørkjær, Louise; Nielsen, Lars Henrik; Bomholt, Katrine Bjørnshave

    . The International Life Saving Federation recommends CPR using face-mask ventilation. It is currently unknown if OH-CPR using face-mask ventilation improves CPR quality. We hypothesized that OH-CPR is superior to standard CPR with face-mask ventilation among surf lifeguards. Methods: Surf lifeguards were trained......Introduction: Ventilation is a priority in drowning resuscitation. Over-the-head CPR (OH-CPR), i.e. with the rescuer located at the top of the victim’s head instead of alongside the victim’s torso, has been demonstrated to be superior when doing bag-valve-mask ventilation compared to standard CPR...... in OH-CPR and standard CPR with face-mask ventilation and randomized to a crossover comparison on a manikin. CPR quality data were obtained from the manikin and video recordings. Interruptions in chest compressions were used as a primary measure of CPR quality. A sample size of 14 participants...

  16. CPR Facts and Stats

    Science.gov (United States)

    ... In Schools Training Kits RQI AHA Blended Learning & eLearning Guide AHA Instructors ECC Educational Conferences Programs CPR ... In Schools Training Kits RQI AHA Blended Learning & eLearning Guide AHA Instructors ECC Educational Conferences Programs CPR ...

  17. Polarization extinction ratio of the polarization crosstalk caused by point pressure force in the polarization-maintaining fiber

    Science.gov (United States)

    Mukhtubayev, Azamat B.; Aksarin, Stanislav M.; Strigalev, Vladimir E.

    2017-11-01

    A study of the orthogonal polarization modes crosstalk changes in the point of different mechanical actions (pressure force) in the polarization-maintaining fiber with straining elliptical cladding is presented. It was found that by increasing of the pressure force the polarization extinction ratio increases nonlinearly. Also revealed the dependence of the extinction coefficient and the angle between vector of the mechanical action and polarization axes of the test fiber, which leads to change the extinction coefficient variable from -57 dB to -25 dB under the pressure force of 0.7 N. Also it was found that the cross angle of the fiber axes doesn't influence on the extinction ratio value of the mechanical induced polarization crosstalk.

  18. Mechanical CPR: Who? When? How?

    Science.gov (United States)

    Poole, Kurtis; Couper, Keith; Smyth, Michael A; Yeung, Joyce; Perkins, Gavin D

    2018-05-29

    In cardiac arrest, high quality cardiopulmonary resuscitation (CPR) is a key determinant of patient survival. However, delivery of effective chest compressions is often inconsistent, subject to fatigue and practically challenging.Mechanical CPR devices provide an automated way to deliver high-quality CPR. However, large randomised controlled trials of the routine use of mechanical devices in the out-of-hospital setting have found no evidence of improved patient outcome in patients treated with mechanical CPR, compared with manual CPR. The limited data on use during in-hospital cardiac arrest provides preliminary data supporting use of mechanical devices, but this needs to be robustly tested in randomised controlled trials.In situations where high-quality manual chest compressions cannot be safely delivered, the use of a mechanical device may be a reasonable clinical approach. Examples of such situations include ambulance transportation, primary percutaneous coronary intervention, as a bridge to extracorporeal CPR and to facilitate uncontrolled organ donation after circulatory death.The precise time point during a cardiac arrest at which to deploy a mechanical device is uncertain, particularly in patients presenting in a shockable rhythm. The deployment process requires interruptions in chest compression, which may be harmful if the pause is prolonged. It is recommended that use of mechanical devices should occur only in systems where quality assurance mechanisms are in place to monitor and manage pauses associated with deployment.In summary, mechanical CPR devices may provide a useful adjunct to standard treatment in specific situations, but current evidence does not support their routine use.

  19. A randomized controlled trial comparing traditional training in cardiopulmonary resuscitation (CPR) to self-directed CPR learning in first year medical students: The two-person CPR study.

    Science.gov (United States)

    Roppolo, Lynn P; Heymann, Rahm; Pepe, Paul; Wagner, James; Commons, Bradford; Miller, Ronna; Allen, Emilie; Horne, Leyla; Wainscott, Michael P; Idris, Ahamed H

    2011-03-01

    The primary purpose of this study was to compare two, shorter, self-directed methods of cardiopulmonary resuscitation (CPR) education for healthcare professionals (HCP) to traditional training with a focus on the trainee's ability to perform two-person CPR. First-year medical students with either no prior CPR for HCP experience or prior training greater than 5 years were randomized to complete one of three courses: 1) HeartCode BLS System, 2) BLS Anytime, or 3) Traditional training. Only data from the adult CPR skills testing station was reviewed via video recording by certified CPR instructors and the Laerdal PC Skill Reporter software program (Laerdal Medical, Stavanger, Norway). There were 180 first-year medical students who met inclusion criteria: 68 were HeartCode BLS System, 53 BLS Anytime group, and 59 traditional group Regarding two-person CPR, 57 (84%) of Heartcode BLS students and 43 (81%) of BLS Anytime students were able to initiate the switch compared to 39 (66%) of traditional course students (p = 0.04). There were no significant differences in the quality of chest compressions or ventilations between the three groups. There was a trend for a much higher CPR skills testing pass rate for the traditional course students. However, failure to "clear to analyze or shock" while using the AED was the most common reason for failure in all groups. The self-directed learning groups not only had a high level of success in initiating the "switch" to two-person CPR, but were not significantly different from students who completed traditional training. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  20. PyCPR - a python-based implementation of the Conjugate Peak Refinement (CPR) algorithm for finding transition state structures.

    Science.gov (United States)

    Gisdon, Florian J; Culka, Martin; Ullmann, G Matthias

    2016-10-01

    Conjugate peak refinement (CPR) is a powerful and robust method to search transition states on a molecular potential energy surface. Nevertheless, the method was to the best of our knowledge so far only implemented in CHARMM. In this paper, we present PyCPR, a new Python-based implementation of the CPR algorithm within the pDynamo framework. We provide a detailed description of the theory underlying our implementation and discuss the different parts of the implementation. The method is applied to two different problems. First, we illustrate the method by analyzing the gauche to anti-periplanar transition of butane using a semiempirical QM method. Second, we reanalyze the mechanism of a glycyl-radical enzyme, namely of 4-hydroxyphenylacetate decarboxylase (HPD) using QM/MM calculations. In the end, we suggest a strategy how to use our implementation of the CPR algorithm. The integration of PyCPR into the framework pDynamo allows the combination of CPR with the large variety of methods implemented in pDynamo. PyCPR can be used in combination with quantum mechanical and molecular mechanical methods (and hybrid methods) implemented directly in pDynamo, but also in combination with external programs such as ORCA using pDynamo as interface. PyCPR is distributed as free, open source software and can be downloaded from http://www.bisb.uni-bayreuth.de/index.php?page=downloads . Graphical Abstract PyCPR is a search tool for finding saddle points on the potential energy landscape of a molecular system.

  1. A novel protocol for dispatcher assisted CPR improves CPR quality and motivation among rescuers-A randomized controlled simulation study.

    Science.gov (United States)

    Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo

    2017-01-01

    Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, pCPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Cardiopulmonary resuscitation (CPR)-related posterior rib fractures in neonates and infants following recommended changes in CPR techniques.

    Science.gov (United States)

    Franke, I; Pingen, A; Schiffmann, H; Vogel, M; Vlajnic, D; Ganschow, R; Born, M

    2014-07-01

    Posterior rib fractures are highly indicative of non-accidental trauma (NAT) in infants. Since 2000, the "two-thumbs" technique for cardiopulmonary resuscitation (CPR) of newborns and infants has been recommended by the American Heart Association (AHA). This technique is similar to the grip on an infant's thorax while shaking. Is it possible that posterior rib fractures in newborns and infants could be caused by the "two-thumbs" technique? Using computerized databases from three German children's hospitals, we identified all infants less than 12 months old who underwent professional CPR within a 10-year period. We included all infants with anterior-posterior chest radiographs taken after CPR. Exclusion criteria were sternotomy, osteopenia, various other bone diseases and NAT. The radiographs were independently reviewed by the Chief of Pediatric Radiology (MB) and a Senior Pediatrician, Head of the local Child Protection Team (IF). Eighty infants with 546 chest radiographs were identified, and 50 of those infants underwent CPR immediately after birth. Data concerning the length of CPR was available for 41 infants. The mean length of CPR was 11min (range: 1-180min, median: 3min). On average, there were seven radiographs per infant. A total of 39 infants had a follow-up radiograph after at least 10 days. No rib fracture was visible on any chest X-ray. The results of this study suggest rib fracture after the use of the "two-thumbs" CPR technique is uncommon. Thus, there should be careful consideration of abuse when these fractures are identified, regardless of whether CPR was performed and what technique used. The discovery of rib fractures in an infant who has undergone CPR without underlying bone disease or major trauma warrants a full child protection investigation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Cardiopulmonary Resuscitation (CPR): First Aid

    Science.gov (United States)

    ... learn CPR properly, take an accredited first-aid training course, including CPR and how to use an automated external defibrillator ( ... and Research. © 1998-2018 Mayo Foundation for Medical Education and Research (MFMER). All rights reserved.

  4. Prevalence and hemodynamic effects of leaning during CPR

    Science.gov (United States)

    Niles, Dana E.; Sutton, Robert M.; Nadkarni, Vinay M.; Glatz, Andrew; Zuercher, Mathias; Maltese, Matthew R.; Eilevstjønn, Joar; Abella, Benjamin S.; Becker, Lance B.; Berg, Robert A.

    2013-01-01

    Background Cardiopulmonary resuscitation (CPR) guidelines recommend complete release between chest compressions (CC). Objective Evaluate the hemodynamic effects of leaning (incomplete chest wall release) during CPR and the prevalence of leaning during CPR. Results In piglet ventricular fibrillation cardiac arrests, 10% and 20% (1.8 kg and 3.6 kg, respectively), leaning during CPR increased right atrial pressures, decreased coronary perfusion pressures, and decreased cardiac index and left ventricular myocardial blood flow by nearly 50%. In contrast, residual leaning of a 260 g accelerometer/ force feedback device did not adversely affect cardiac index or myocardial blood flow. Among 108 adult in-hospital CPR events, leaning ≥2.5 kg was demonstrable in 91% of the events and 12% of the evaluated CC. For 12 children with in-hospital CPR, 28% of CC had residual leaning ≥2.5 kg and 89% had residual leaning ≥0.5 kg. Conclusions Leaning during CPR increases intrathoracic pressure, decreases coronary perfusion pressure, and decreases cardiac output and myocardial blood flow. Leaning is common during CPR. PMID:22208173

  5. Can the cerebroplacental ratio (CPR) predict intrapartum fetal compromise? : a prospective observational study

    OpenAIRE

    Page, Ann-Sophie; Page, Geert; Dehaene, Isabelle; Roets, Ellen; Roelens, Kristien

    2017-01-01

    Objective: To investigate the potential clinical use of serial fetal CPR measurements during the last month of pregnancy for the prediction of adverse perinatal outcome in unselected low-risk pregnancies. Methods: A multicenter prospective observational cohort study in 315 consecutively recruited low-risk pregnancies. All eligible pregnancies underwent serial sonographic evaluation of fetal weight and Doppler indices at two week intervals, from 36 weeks gestation until delivery. Data were ...

  6. The development of CPR.

    Science.gov (United States)

    McLennan, Stuart

    2008-10-17

    Cardiopulmonary resuscitation (CPR) is now the standard treatment for someone having a cardiac arrest. It is, however, a procedure that has emerged only relatively recently. For a number of scientific and religious reasons, it was long considered impossible, even blasphemous, to attempt to reverse 'death'. Because of these factors, the area of resuscitation failed to progress until the Enlightenment in the 18th Century. The main elements of resuscitation were then developed over the next 200 years, and eventually brought together to create CPR in the early 1960s. The increased demands that morality was seen to place on the medical profession to combat sudden cardiac death subsequent to this development may have been an important factor in why CPR has come to be used in the widespread manner it currently is.

  7. Medical students and physical education students as CPR instructors: an appropriate solution to the CPR-instructor shortage in secondary schools?

    OpenAIRE

    Cuijpers, P. J. P. M.; Bookelman, G.; Kicken, W.; de Vries, W.; Gorgels, A. P. M.

    2016-01-01

    Background Integrating cardiopulmonary resuscitation (CPR) training in secondary schools will increase the number of potential CPR providers. However, currently too few certified instructors are available for this purpose. Training medical students and physical education student teachers to become CPR instructors could decrease this shortage. Aim Examine whether medical students and physical education student teachers can provide CPR training for secondary school pupils as well as (i.?e., non...

  8. Two-thumb technique is superior to two-finger technique during lone rescuer infant manikin CPR.

    Science.gov (United States)

    Udassi, Sharda; Udassi, Jai P; Lamb, Melissa A; Theriaque, Douglas W; Shuster, Jonathan J; Zaritsky, Arno L; Haque, Ikram U

    2010-06-01

    Infant CPR guidelines recommend two-finger chest compression with a lone rescuer and two-thumb with two rescuers. Two-thumb provides better chest compression but is perceived to be associated with increased ventilation hands-off time. We hypothesized that lone rescuer two-thumb CPR is associated with increased ventilation cycle time, decreased ventilation quality and fewer chest compressions compared to two-finger CPR in an infant manikin model. Crossover observational study randomizing 34 healthcare providers to perform 2 min CPR at a compression rate of 100 min(-1) using a 30:2 compression:ventilation ratio comparing two-thumb vs. two-finger techniques. A Laerdal Baby ALS Trainer manikin was modified to digitally record compression rate, compression depth and compression pressure and ventilation cycle time (two mouth-to-mouth breaths). Manikin chest rise with breaths was video recorded and later reviewed by two blinded CPR instructors for percent effective breaths. Data (mean+/-SD) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as pCPR, but there was no significant difference in percent effective breaths delivered between the two techniques. Two-thumb CPR had 4 fewer delivered compressions per minute, which may be offset by far more effective compression depth and compression pressure compared to two-finger technique. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  9. Improving cardiopulmonary resuscitation with a CPR feedback device and refresher simulations (CPR CARES Study): a randomized clinical trial.

    Science.gov (United States)

    Cheng, Adam; Brown, Linda L; Duff, Jonathan P; Davidson, Jennifer; Overly, Frank; Tofil, Nancy M; Peterson, Dawn T; White, Marjorie L; Bhanji, Farhan; Bank, Ilana; Gottesman, Ronald; Adler, Mark; Zhong, John; Grant, Vincent; Grant, David J; Sudikoff, Stephanie N; Marohn, Kimberly; Charnovich, Alex; Hunt, Elizabeth A; Kessler, David O; Wong, Hubert; Robertson, Nicola; Lin, Yiqun; Doan, Quynh; Duval-Arnould, Jordan M; Nadkarni, Vinay M

    2015-02-01

    The quality of cardiopulmonary resuscitation (CPR) affects hemodynamics, survival, and neurological outcomes following pediatric cardiopulmonary arrest (CPA). Most health care professionals fail to perform CPR within established American Heart Association guidelines. To determine whether "just-in-time" (JIT) CPR training with visual feedback (VisF) before CPA or real-time VisF during CPA improves the quality of chest compressions (CCs) during simulated CPA. Prospective, randomized, 2 × 2 factorial-design trial with explicit methods (July 1, 2012, to April 15, 2014) at 10 International Network for Simulation-Based Pediatric Innovation, Research, & Education (INSPIRE) institutions running a standardized simulated CPA scenario, including 324 CPR-certified health care professionals assigned to 3-person resuscitation teams (108 teams). Each team was randomized to 1 of 4 permutations, including JIT training vs no JIT training before CPA and real-time VisF vs no real-time VisF during simulated CPA. The proportion of CCs with depth exceeding 50 mm, the proportion of CPR time with a CC rate of 100 to 120 per minute, and CC fraction (percentage CPR time) during simulated CPA. The quality of CPR was poor in the control group, with 12.7% (95% CI, 5.2%-20.1%) mean depth compliance and 27.1% (95% CI, 14.2%-40.1%) mean rate compliance. JIT training compared with no JIT training improved depth compliance by 19.9% (95% CI, 11.1%-28.7%; P 89.0%) in all groups. Combining both interventions showed the highest compliance with American Heart Association guidelines but was not significantly better than either intervention in isolation. The quality of CPR provided by health care professionals is poor. Using novel and practical technology, JIT training before CPA or real-time VisF during CPA, alone or in combination, improves compliance with American Heart Association guidelines for CPR that are associated with better outcomes. clinicaltrials.gov Identifier: NCT02075450.

  10. CPR - adult

    Science.gov (United States)

    ... heartbeat has stopped. This may happen after an electric shock , drowning, or heart attack. CPR involves: Rescue ... to swim. Teach your child to watch for cars and ride bikes safely. Teach your child firearm ...

  11. Report on the Southern Ocean Continuous Plankton Recorder (SO-CPR Standards Workshop 2016: SCAR SO-CPR Database Expert Group

    Directory of Open Access Journals (Sweden)

    Kunio T. Takahashi

    2017-07-01

    Full Text Available The“Southern Ocean Continuous Plankton Recorder (SO-CPR Survey Standards Workshop”was held at the Australian Antarctic Division on 12−16December 2016. The purposes of the workshop were to confirm that consistent and high standards of species identification, methodology, and data quality were being maintained amongst the main analysts in the SO-CPR Survey, and to discuss future training methods, including a SO-CPR manual that will include a counting rule book, and a future road map for the SO-CPR program. During the workshop we discussed a range of topics including: taxonomic resolution issues (particularly for Foraminifera and euphausiid larval identification and staging; laboratory methods (preservation and storage, with emphasis on maintaining correct pH; shipboard techniques; training methods; data handling (metadata, database, data sharing; gap analysis (spatial, temporal, data, quantitative; and future workshops/conferences, including comprehensive training workshops for emerging SO-CPR survey partners (India. We agreed that there should be a larger workshop every two years to ensure that the high standards of the SO-CPR program are maintained.

  12. Training hospital providers in basic CPR skills in Botswana: Acquisition, retention and impact of novel training techniques☆

    Science.gov (United States)

    Meaney, Peter A.; Sutton, Robert M.; Tsima, Billy; Steenhoff, Andrew P.; Shilkofski, Nicole; Boulet, John R.; Davis, Amanda; Kestler, Andrew M.; Church, Kasey K.; Niles, Dana E.; Irving, Sharon Y.; Mazhani, Loeto; Nadkarni, Vinay M.

    2013-01-01

    Objective Globally, one third of deaths each year are from cardiovascular diseases, yet no strong evidence supports any specific method of CPR instruction in a resource-limited setting. We hypothesized that both existing and novel CPR training programs significantly impact skills of hospital-based healthcare providers (HCP) in Botswana. Methods HCP were prospectively randomized to 3 training groups: instructor led, limited instructor with manikin feedback, or self-directed learning. Data was collected prior to training, immediately after and at 3 and 6 months. Excellent CPR was prospectively defined as having at least 4 of 5 characteristics: depth, rate, release, no flow fraction, and no excessive ventilation. GEE was performed to account for within subject correlation. Results Of 214 HCP trained, 40% resuscitate ≥1/month, 28% had previous formal CPR training, and 65% required additional skills remediation to pass using AHA criteria. Excellent CPR skill acquisition was significant (infant: 32% vs. 71%, p CPR skill retention was significant at 3 (39% vs. 70%, p CPR skills were retained to 3 months (34% vs. 51%, p = 0.02). On multivariable analysis, low cognitive score and need for skill remediation, but not instruction method, impacted CPR skill performance. Conclusions HCP in resource-limited settings resuscitate frequently, with little CPR training. Using existing training, HCP acquire and retain skills, yet often require remediation. Novel techniques with increased student: instructor ratio and feedback manikins were not different compared to traditional instruction. PMID:22561463

  13. Effects of head-up vs. supine CPR on cerebral oxygenation and cerebral metabolism - a prospective, randomized porcine study.

    Science.gov (United States)

    Putzer, Gabriel; Braun, Patrick; Martini, Judith; Niederstätter, Ines; Abram, Julia; Lindner, Andrea Katharina; Neururer, Sabrina; Mulino, Miriam; Glodny, Bernhard; Helbok, Raimund; Mair, Peter

    2018-05-01

    Recent studies have shown that during cardiopulmonary resuscitation (CPR) head-up position (HUP) as compared to standard supine position (SUP) decreases intracranial pressure (ICP) and increases cerebral perfusion pressure (CPP). The impact of this manoeuvre on brain oxygenation and metabolism is not clear. We therefore investigated HUP as compared to SUP during basic life support (BLS) CPR for their effect on brain oxygenation and metabolism. Twenty pigs were anaesthetized and instrumented. After 8 min of cardiac arrest (CA) pigs were randomized to either HUP or SUP and resuscitated mechanically for 20 min. Mean arterial pressure (MAP), ICP, CPP, cerebral regional oxygen saturation (rSO 2 ) and brain tissue oxygen tension (P bt O 2 ) were measured at baseline, after CA and every 5 min during CPR. Cerebral venous oxygen saturation (S cv O 2 ) was measured at baseline, after CA and after 20 min of CPR. Cerebral microdialysis parameters, e.g. lactate/pyruvate ratio (L/P ratio) were taken at baseline and the end of the experiment. ICP was significantly lower in HUP compared to SUP animals after 5 min (18.0 ± 4.5 vs. 24.1 ± 5.2 mmHg; p = 0.033) and 20 min (12.0 ± 3.4 vs. 17.8 ± 4.3 mmHg; p = 0.023) of CPR. Accordingly, CPP was significantly higher in the HUP group after 5 min (11.2 ± 9.5 vs. 1.0 ± 9.2 mmHg; p = 0.045) and 20 min (3.4 ± 6.4 vs. -3.8 ± 2.8 mmHg; p = 0.023) of CPR. However, no difference was found in rSO 2 , P bt O 2 , S cv O 2 and L/P ratio between groups after 20 min of CPR. In this animal model of BLS CPR, HUP as compared to SUP did not improve cerebral oxygenation or metabolism. Copyright © 2018. Published by Elsevier B.V.

  14. Learn CPR You Can Do It!

    Science.gov (United States)

    ... first aid training. Please try to attend a CPR training course in your community and help save a life. Francais Español ... Life Sciences Discovery Fund © 1998 - 2010 Learn CPR . All Rights Reserved. Replication of any of the ...

  15. CPR: A Real Lifesaver (For Kids)

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... English Español CPR: A Real Lifesaver KidsHealth / For Kids / CPR: A Real Lifesaver What's in this article? ...

  16. CPR: Adult

    Medline Plus

    Full Text Available Refresher Center Home FIRST AID, CPR and AED LIFEGUARDING Refresher Putting It All Together: CPR—Adult (2:03) Refresher videos only utilize this player QUICK LINKS Home RedCross.org Purchase Course Materials Shop Our Store ...

  17. CPR: Infant

    Medline Plus

    Full Text Available Refresher Center Home FIRST AID, CPR and AED LIFEGUARDING Refresher Putting It All Together: CPR—Infant (1:52) Refresher videos only utilize this player QUICK LINKS Home RedCross.org Purchase Course Materials Shop Our Store ...

  18. Self-adaptive demodulation for polarization extinction ratio in distributed polarization coupling.

    Science.gov (United States)

    Zhang, Hongxia; Ren, Yaguang; Liu, Tiegen; Jia, Dagong; Zhang, Yimo

    2013-06-20

    A self-adaptive method for distributed polarization extinction ratio (PER) demodulation is demonstrated. It is characterized by dynamic PER threshold coupling intensity (TCI) and nonuniform PER iteration step length (ISL). Based on the preset PER calculation accuracy and original distribution coupling intensity, TCI and ISL can be made self-adaptive to determine contributing coupling points inside the polarizing devices. Distributed PER is calculated by accumulating those coupling points automatically and selectively. Two different kinds of polarization-maintaining fibers are tested, and PERs are obtained after merely 3-5 iterations using the proposed method. Comparison experiments with Thorlabs commercial instrument are also conducted, and results show high consistency. In addition, the optimum preset PER calculation accuracy of 0.05 dB is obtained through many repeated experiments.

  19. Pharmacotherapy In Cardiopulmonary Resuscitation (CPR)

    OpenAIRE

    GÜNAYDIN, Berrin

    2014-01-01

    Cardiac arrest is defined as cessation of cardiac mechanical activity. Cardiopulmonary resuscitation (CPR) is an attempt to restore spontaneous circulation through several maneuvers and techniques. Although the two interventions, which are competent basic life support and prompt defibrillation, improve the survival rate, several adjuvant cardiac medication drugs are advocated to treat cardiac arrest during advanced cardiac life support. Since the introduction of modern CPR there have been man...

  20. Applying CPR to a gas utility

    International Nuclear Information System (INIS)

    Lowe, R.

    1995-01-01

    The latest management tool to hit the United States over the past five years is Core Process Re-engineering (CPR). Though not as radical a procedure as the well-known rescue method it shares an abbreviation with, it is viewed as the radical thinking of a business process. CPR has helped breathe new life into gas and electric utilities in recent years, which have been using it to find ways to increase customer satisfaction, decrease operating costs, reduce process time and/or increase quality. The first phase of a typical project identifies and reviews current processes and obtains information that can point out re-engineering opportunities. The second phase involves the actual redesign of the current process. In this phase new teams may be formed, since the skill requirements are different (creative thinking becomes very important, for instance). Once alternatives are finalized and approved, the actual change process begins. Implementing all the recommendations can take several years, primarily because of labor and regulatory implications; therefore, planning the implementation is the most important part of the project. First, develop an overall implementation strategy. This overall strategy should address four major questions: What to implement? Who will implement? When to implement? How to implement? CPR is not an automatic solution to a problem. Any company wanting to expedite a CPR effort should consider the following factors: Align the CPR objectives to the overall company objectives; Ensure that senior management is actively involved and supports the CPR activities; Select the right team of people and ensure they are committed to the project; Develop a case for change and instill a sense of urgency in all the stakeholders; Focus on business results and not on specific activities; and Communicate, communicate, communicate

  1. A mixed-methods study exploring student nurses’ understanding of futile CPR

    OpenAIRE

    Batty, Emma

    2014-01-01

    Abstract Background: Futile CPR has the potential to inflict significant, avoidable harms on dying patients. Futile CPR is widely debated in the literature, but there is little research into futile CPR in the context of nursing. There are no published studies exploring student nurses’ understanding of futile CPR. Aim: To explore student nurses’ understanding of futile CPR Methods: A mixed methods study, using questionnaires to establish background data and identify prominent issues. ...

  2. Optimising neutron polarizers--measuring the flipping ratio and related quantities

    CERN Document Server

    Goossens, D J

    2002-01-01

    The continuing development of gaseous spin polarized sup 3 He transmission filters for use as neutron polarizers makes the choice of optimum thickness for these filters an important consideration. The 'quality factors' derived for the optimisation of transmission filters for particular measurements are general to all neutron polarizers. In this work optimisation conditions for neutron polarizers are derived and discussed for the family of studies related to measuring the flipping ratio from samples. The application of the optimisation conditions to sup 3 He transmission filters and other types of neutron polarizers is discussed. Absolute comparisons are made between the effectiveness of different types of polarizers for this sort of work.

  3. Bioinformatics analysis for structure and function of CPR of Plasmodium falciparum.

    Science.gov (United States)

    Fan, Zhigang; Zhang, Lingmin; Yan, Guogang; Wu, Qiang; Gan, Xiufeng; Zhong, Saifeng; Lin, Guifen

    2011-02-01

    To analyse the structure and function of NADPH-cytochrome p450 reductase (CYPOR or CPR) from Plasmodium falciparum (Pf), and to predict its' drug target and vaccine target. The structure, function, drug target and vaccine target of CPR from Plasmodium falciparum were analyzed and predicted by bioinformatics methods. PfCPR, which was older CPR, had close relationship with the CPR from other Plasmodium species, but it was distant from its hosts, such as Homo sapiens and Anopheles. PfCPR was located in the cellular nucleus of Plasmodium falciparum. 335aa-352aa and 591aa - 608aa were inserted the interior side of the nuclear membrane, while 151aa-265aa was located in the nucleolus organizer regions. PfCPR had 40 function sites and 44 protein-protein binding sites in amino acid sequence. The teriary structure of 1aa-700aa was forcep-shaped with wings. 15 segments of PfCPR had no homology with Homo sapien CPR and most were exposed on the surface of the protein. These segments had 25 protein-protein binding sites. While 13 other segments all possessed function sites. The evolution or genesis of Plasmodium falciparum is earlier than those of Homo sapiens. PfCPR is a possible resistance site of antimalarial drug and may involve immune evasion, which is associated with parasite of sporozoite in hepatocytes. PfCPR is unsuitable as vaccine target, but it has at least 13 ideal drug targets. Copyright © 2011 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  4. Effects of bystander CPR following out-of-hospital cardiac arrest on hospital costs and long-term survival.

    Science.gov (United States)

    Geri, Guillaume; Fahrenbruch, Carol; Meischke, Hendrika; Painter, Ian; White, Lindsay; Rea, Thomas D; Weaver, Marcia R

    2017-06-01

    Bystander cardiopulmonary resuscitation (CPR) is associated with a greater likelihood of survival to hospital discharge after out-of-hospital cardiac arrest (OHCA). However the long-term survival benefits in relationship to cost have not been well-studied. We evaluated bystander CPR, hospital-based costs, and long-term survival following OHCA in order to assess the potential cost-effectiveness of bystander CPR. We conducted a retrospective cohort study of consecutive EMS-treated OHCA patients >=12years who arrested prior to EMS arrival and outside a nursing facility between 2001 and 2010 in greater King County, WA. Utstein-style information was obtained from the EMS registry, including 5-year survival. Costs from the OHCA hospitalization were obtained from the Washington State Comprehensive Hospital Abstract Reporting System. Cost effectiveness was based on hospital costs divided by quality-adjusted life years (QALYs) for a 5-year follow-up window. Of the 4448 eligible patients, 18.5% (n=824) were discharged alive from hospital and 12.1% (n=539) were alive at 5 years. Five-year survival was higher in patients who received bystander CPR (14.3% vs. 8.7%, pbystander CPR. The average (SD) total cost of the initial acute care hospitalization was USD 19,961 (40,498) for all admitted patients and USD 75,175 (52,276) for patients alive at year 5. The incremental cost-effectiveness ratio associated with bystander CPR was USD 48,044 per QALY. Based on this population-based investigation, bystander CPR was positively associated with long-term survival and appears cost-effective. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. RECOVER evidence and knowledge gap analysis on veterinary CPR. Part 1: Evidence analysis and consensus process: collaborative path toward small animal CPR guidelines.

    Science.gov (United States)

    Boller, Manuel; Fletcher, Daniel J

    2012-06-01

    To describe the methodology used by the Reassessment Campaign on Veterinary Resuscitation (RECOVER) to evaluate the scientific evidence relevant to small animal CPR and to compose consensus-based clinical CPR guidelines for dogs and cats. This report is part of a series of 7 articles on the RECOVER evidence and knowledge gap analysis and consensus-based small animal CPR guidelines. It describes the organizational structure of RECOVER, the evaluation process employed, consisting of standardized literature searches, the analysis of relevant articles according to study design, species and predefined quality markers, and the drafting of clinical CPR guidelines based on these data. Therefore, this article serves as the methodology section for the subsequent 6 RECOVER articles. Academia, referral practice. RECOVER is a collaborative initiative that systematically evaluated the evidence on 74 topics relevant to small animal CPR and generated 101 clinical CPR guidelines from this analysis. All primary contributors were veterinary specialists, approximately evenly split between academic institutions and private referral practices. The evidence evaluation and guideline drafting processes were conducted according to a predefined sequence of steps designed to reduce bias and increase the repeatability of the findings, including multiple levels of review, culminating in a consensus process. Many knowledge gaps were identified that will allow prioritization of research efforts in veterinary CPR. Collaborative systematic evidence review is organizationally challenging but feasible and effective in veterinary medicine. More experience is needed to refine the process. © Veterinary Emergency and Critical Care Society 2012.

  6. Simulation of advanced accumulator and its application in CPR1000 LBLOCA analysis

    International Nuclear Information System (INIS)

    Hu, Hongwei; Shan, Jianqiang; Gou, Junli; Cao, Jianhua; Shen, Yonggang; Fu, Xiangang

    2014-01-01

    Highlights: • The analysis model was developed for advanced accumulator. • The sensitivity analysis of each key parameter was performed. • The LBLOCA was analyzed for the CPR1000 with advanced accumulator. • The analysis shows that advanced accumulator can improve CPR1000 safety performance. - Abstract: The advanced accumulator is designed to improve the safety and reliability of CPR1000 by providing a small injection flow to keep the reactor core in flooded condition. Thus, the core still stays in a cooling state without the intervention of low pressure safety injection and the startup grace time of the low pressure safety injection pump can be greatly extended. A new model for the advanced accumulator, which is based on the basic conservation equations, is developed and incorporated into RELAP5/MOD 3.3. The simulation of the advanced accumulator can be carried out and results show that the behavior of the advanced accumulator satisfied its primary design target. There is a large flow in the advanced accumulator at the initial stage. When the accumulator water level is lower than the stand pipe, a vortex appears in the damper, which results in a large pressure drop and a small flow. And then the sensitivity analysis is performed and the major factors which affected the flow rate of the advanced accumulator were obtained, including the damper diameter, the initial volume ratio of the water and the nitrogen and the diameter ratio of the standpipe and the small pipe. Additionally, the primary coolant loop cold leg double-ended guillotine break LBLOCA in CPR1000 with advanced accumulator is analyzed. The results show that the criterion for maximum cladding temperature limit (1477 K) (NRC, 1992) can be met ever with 200 s after the startup of the low pressure safety injection. From this point of view, passive advanced accumulator can strive a longer grace time for LPSI. Thus the reliability, safety and economy of the reactor system can be improved

  7. Effect of mobile application-based versus DVD-based CPR training on students’ practical CPR skills and willingness to act: a cluster randomised study

    Science.gov (United States)

    Nord, Anette; Svensson, Leif; Hult, Håkan; Kreitz-Sandberg, Susanne; Nilsson, Lennart

    2016-01-01

    Objectives The aim was to compare students’ practical cardiopulmonary resuscitation (CPR) skills and willingness to perform bystander CPR, after a 30 min mobile application (app)-based versus a 50 min DVD-based training. Settings Seventh grade students in two Swedish municipalities. Design A cluster randomised trial. The classes were randomised to receive app-based or DVD-based training. Willingness to act and practical CPR skills were assessed, directly after training and at 6 months, by using a questionnaire and a PC Skill Reporting System. Data on CPR skills were registered in a modified version of the Cardiff test, where scores were given in 12 different categories, adding up to a total score of 12–48 points. Training and measurements were performed from December 2013 to October 2014. Participants 63 classes or 1232 seventh grade students (13-year-old) were included in the study. Primary and secondary outcome measures Primary end point was the total score of the modified Cardiff test. The individual variables of the test and self-reported willingness to make a life-saving intervention were secondary end points. Results The DVD-based group was superior to the app-based group in CPR skills; a total score of 36 (33–38) vs 33 (30–36) directly after training (pCPR skill components. Both groups improved compression depth from baseline to follow-up. If a friend suffered cardiac arrest, 78% (DVD) versus 75% (app) would do compressions and ventilations, whereas only 31% (DVD) versus 32% (app) would perform standard CPR if the victim was a stranger. Conclusions At 6 months follow-up, the 50 min DVD-based group showed superior CPR skills compared with the 30 min app-based group. The groups did not differ in regard to willingness to make a life-saving effort. PMID:27130166

  8. CORRELATION OF CEREBROPLACENTAL RATIO WITH PERINATAL OUTCOME IN INTRAUTERINE GROWTH RESTRICTION

    Directory of Open Access Journals (Sweden)

    Sajala Vimalraj

    2016-07-01

    Full Text Available BACKGROUND Doppler velocimetry is a non-invasive method of measuring changes in blood flow. (1,2,3 Randomised Control Trials (RCTs have shown that using Doppler indices in the management of Intrauterine Growth Restriction (IUGR cases leads to a significant reduction in perinatal mortality rate. Deterioration of various Doppler indices precedes abnormal Biophysical Profile (BPP by 1-2 weeks. (1,2,3,4 Umbilical artery indices only reflect the placental status. Fetal response to this increasing placental insufficiency can be deduced from studying the Cerebroplacental Ratio {CPR}, which gives us an idea of the fetal response to the placental status and is potentially more advantageous in predicting fetal outcome. OBJECTIVES To compare CPR in predicting fetal outcome with UA and MCA indices. MATERIALS AND METHODS Prospective cohort study of cases of IUGR - January 2013 to December 2013. 180 cases of clinically diagnosed IUGR were selected. Obstetric USG and Doppler was performed. The S/D ratio, RI, PR values were obtained and CPR calculated. All cases were managed as per the protocol then in place using U/A SD ratios for determining the timing & mode of termination RESULTS Of 180 cases of IUGR were selected most women were primigravidae, 20-34 years, and from low socio-economic status. (3 25 women (13.8% had oligohydramnios (AFI <5. Of these women, 24 had an abnormal CPR, 1 normal CPR. 47% with abnormal CPR had caesarean for fetal distress. Birth weight was <1.5 kg in 14.4% of patients all of whom were in the abnormal CPR group. 7.5% had an Apgar <7; all these babies were in the abnormal CPR group. 43.9% of babies from the abnormal CPR group needed resuscitation. 79% of the abnormal CPR group babies needed NICU admission. CONCLUSION Utilization of only UA and MCA indices may cause unnecessary early intervention in some cases. (1,5 CPR can help triage pregnancies in need of termination while prolonging those which are relatively stable so as to gain

  9. Barriers and Facilitators to Learning and Performing Cardiopulmonary Resuscitation (CPR) in Neighborhoods with Low Bystander CPR Prevalence and High Rates of Cardiac Arrest in Columbus, Ohio

    Science.gov (United States)

    Sasson, Comilla; Haukoos, Jason S.; Bond, Cindy; Rabe, Marilyn; Colbert, Susan H.; King, Renee; Sayre, Michael; Heisler, Michele

    2013-01-01

    Background Residents who live in neighborhoods that are primarily African-American, Latino, or poor are more likely to have an out-of-hospital cardiac arrest (OHCA), less likely to receive cardiopulmonary resuscitation (CPR), and less likely to survive. No prior studies have been conducted to understand the contributing factors that may decrease the likelihood of residents learning and performing CPR in these neighborhoods. The goal of this study was to identify barriers and facilitators to learning and performing CPR in three low-income, “high-risk” predominantly African American, neighborhoods in Columbus, Ohio. Methods and Results Community-Based Participatory Research (CBPR) approaches were used to develop and conduct six focus groups in conjunction with community partners in three target high-risk neighborhoods in Columbus, Ohio in January-February 2011. Snowball and purposeful sampling, done by community liaisons, was used to recruit participants. Three reviewers analyzed the data in an iterative process to identify recurrent and unifying themes. Three major barriers to learning CPR were identified and included financial, informational, and motivational factors. Four major barriers were identified for performing CPR and included fear of legal consequences, emotional issues, knowledge, and situational concerns. Participants suggested that family/self-preservation, emotional, and economic factors may serve as potential facilitators in increasing the provision of bystander CPR. Conclusion The financial cost of CPR training, lack of information, and the fear of risking one's own life must be addressed when designing a community-based CPR educational program. Using data from the community can facilitate improved design and implementation of CPR programs. PMID:24021699

  10. Broadband non-polarizing terahertz beam splitters with variable split ratio

    KAUST Repository

    Wei, Minggui

    2017-08-15

    Seeking effective terahertz functional devices has always aroused extensive attention. Of particular interest is the terahertz beam splitter. Here, we have proposed, designed, manufactured, and tested a broadband non-polarizing terahertz beam splitter with a variable split ratio based on an all-dielectric metasurface. The metasurface was created by patterning a dielectric surface of the N-step phase gradient and etching to a few hundred micrometers. The conversion efficiency as high as 81% under the normal incidence at 0.7 THz was achieved. Meanwhile, such a splitter works well over a broad frequency range. The split ratio of the proposed design can be continuously tuned by simply shifting the metasurface, and the angle of emergences can also be easily adjusted by choosing the step of phase gradients. The proposed design is non-polarizing, and its performance is kept under different polarizations.

  11. Broadband non-polarizing terahertz beam splitters with variable split ratio

    Science.gov (United States)

    Wei, Minggui; Xu, Quan; Wang, Qiu; Zhang, Xueqian; Li, Yanfeng; Gu, Jianqiang; Tian, Zhen; Zhang, Xixiang; Han, Jiaguang; Zhang, Weili

    2017-08-01

    Seeking effective terahertz functional devices has always aroused extensive attention. Of particular interest is the terahertz beam splitter. Here, we have proposed, designed, manufactured, and tested a broadband non-polarizing terahertz beam splitter with a variable split ratio based on an all-dielectric metasurface. The metasurface was created by patterning a dielectric surface of the N-step phase gradient and etching to a few hundred micrometers. The conversion efficiency as high as 81% under the normal incidence at 0.7 THz was achieved. Meanwhile, such a splitter works well over a broad frequency range. The split ratio of the proposed design can be continuously tuned by simply shifting the metasurface, and the angle of emergences can also be easily adjusted by choosing the step of phase gradients. The proposed design is non-polarizing, and its performance is kept under different polarizations.

  12. Broadband non-polarizing terahertz beam splitters with variable split ratio

    KAUST Repository

    Wei, Minggui; Xu, Quan; Wang, Qiu; Zhang, Xueqian; Li, Yanfeng; Gu, Jianqiang; Tian, Zhen; Zhang, Xixiang; Han, Jiaguang; Zhang, Weili

    2017-01-01

    Seeking effective terahertz functional devices has always aroused extensive attention. Of particular interest is the terahertz beam splitter. Here, we have proposed, designed, manufactured, and tested a broadband non-polarizing terahertz beam splitter with a variable split ratio based on an all-dielectric metasurface. The metasurface was created by patterning a dielectric surface of the N-step phase gradient and etching to a few hundred micrometers. The conversion efficiency as high as 81% under the normal incidence at 0.7 THz was achieved. Meanwhile, such a splitter works well over a broad frequency range. The split ratio of the proposed design can be continuously tuned by simply shifting the metasurface, and the angle of emergences can also be easily adjusted by choosing the step of phase gradients. The proposed design is non-polarizing, and its performance is kept under different polarizations.

  13. Dissemination of CPR video self-instruction materials to secondary trainees: results from a hospital-based CPR education trial

    Science.gov (United States)

    Ikeda, Daniel J.; Buckler, David G.; Li, Jiaqi; Agarwal, Amit K.; Di Taranti, Laura J.; Kurtz, James; dos Reis, Ryan; Leary, Marion; Abella, Benjamin S.; Blewer, Audrey L.

    2016-01-01

    Background Cardiopulmonary resuscitation (CPR) video self-instruction (VSI) materials have been promoted as a scalable approach to increase the prevalence of CPR skills among the lay public, in part due to the opportunity for secondary training (i.e., sharing of training materials). However, the motivations for, and barriers to, disseminating VSI materials to secondary trainees is poorly understood. Methods This work represents an ancillary investigation of a prospective hospital-based CPR education trial in which family members of cardiac patients were trained using VSI. Mixed-methods surveys were administered to primary trainees six months after initial enrollment. Surveys were designed to capture motivations for, and barriers to, sharing VSI materials, the number of secondary trainees with whom materials were shared, and the settings, timing, and recipients of trainings. Results Between 07/2012–05/2015, 653 study participants completed a six-month follow-up interview. Of those, 345 reported sharing VSI materials with 1455 secondary trainees. Materials were shared most commonly with family members. In a logistic regression analysis, participants in the oldest quartile (age > 63 years) were less likely to share materials compared to those in the youngest quartile (age ≤ 44 years, OR 0.58, CI 0.37–0.90, p=0.02). Among the 308 participants who did not share their materials, time constraints was the most commonly cited barrier for not sharing. Conclusions VSI materials represent a strategy for secondary dissemination of CPR training, yet older individuals have a lower likelihood of sharing relative to younger individuals. Further work is warranted to remedy perceived barriers to CPR dissemination among the lay public using VSI approaches. PMID:26776900

  14. An analytical framework for common-pool resource–large technical system (CPR-LTS constellations

    Directory of Open Access Journals (Sweden)

    Pär Blomkvist

    2013-02-01

    Full Text Available This paper introduces an analytical framework for a special phenomenon: when a common-pool resource (CPR institution and a large technical system (LTS are connected and mutually interdependent. The CPR in this case is a node managed by its appropriators within a centrally planned and managed system; here named CPR-LTS constellations. Our framework is empirically derived from two historical investigations of CPR institutions within two LTSs, the agricultural-technical system and the road transport system of Sweden. By comparing similarities and differences it is possible to identify paths to successes and failures. To understand why one survived and the other disappeared we connect Elinor Ostrom’s theories about management of CPRs with Thomas P. Hughes’s theories about LTSs. We are proposing a framework that can bridge the gap between theories about management of CPRs and LTSs. By combining the two theories it should be possible to better understand how small-scale producers using bottom-up CPRs can be linked to top-down LTSs.We will argue that to fit within an LTS, a CPR needs alignment between different parts or components within the constellation/system and alignment with other systems and institutions in society. We propose three analytical levels to deal with the phenomenon of aligning a CPR project to an existing, large sociotechnical system:Local alignment (CPR: How are CPRs organized and managed at local sites?Sociotechnical alignment (CPR-LTS: How are CPRs connected to the sociotechnical system?Contextual alignment: How are CPR-LTS constellations aligned with neighboring institutions and systems in society?Our work indicates that for successful management of a CPR-LTS constellation it is important that the CPR be included in legislation and that government agencies support the CPR in alignment with the LTS. Legislators must recognize the CPR-part in the CPR-LTS constellation so that its institutional body is firmly established in

  15. The use of CPR data in fisheries research [review article

    Science.gov (United States)

    Corten, A.; Lindley, J. A.

    2003-08-01

    The Continuous Plankton Recorder (CPR) survey was initiated partly to contribute to our understanding of the variability of fish stocks and as a potential method for predicting fish distributions from the abundance and composition of the plankton. The latter objective has been superseded by technological developments in fish detection, but the former has been the subject of continuing, and in recent years expanding use of the CPR data. Examples are presented of application of the data to studies on North Sea herring, cod, mackerel, blue whiting and redfish as well as more general plankton studies relevant to fisheries research. Variations in the migration patterns of herring as well as recruitment have been related to abundances and species composition of the plankton in the CPR survey. Extensive use has been made of the CPR data in relation to cod, particularly in the development and testing of the ‘match-mismatch’ hypothesis. Advection of sufficient numbers of Calanus from the core oceanic areas of its distribution into the areas where the cod stocks occur may partly determine the success of those stocks. The analysis of the distribution and abundances of mackerel larvae in the CPR survey have shown contrasting variations between the North Sea and Celtic Sea. The expansion of the horse mackerel fishery in the north-eastern North Sea since 1987 has been related to physical events and a ‘regime shift’ in the plankton, described from CPR data. The oceanic spawning areas of the blue whiting and redfish were highlighted by the expansion of the CPR survey into the north-eastern and north-western Atlantic respectively. These results helped to focus the attention of fisheries scientists on stocks that have subsequently become the targets for commercial exploitation. The results of the CPR survey, particularly those on Calanusfinmarchicus, the phytoplankton standing stock as measured by the CPR colour index, the overall patterns of trends in plankton abundance and

  16. Comparison of team-focused CPR vs standard CPR in resuscitation from out-of-hospital cardiac arrest: Results from a statewide quality improvement initiative.

    Science.gov (United States)

    Pearson, David A; Darrell Nelson, R; Monk, Lisa; Tyson, Clark; Jollis, James G; Granger, Christopher B; Corbett, Claire; Garvey, Lee; Runyon, Michael S

    2016-08-01

    Team-focused CPR (TFCPR) is a choreographed approach to cardiopulmonary resuscitation (CPR) with emphasis on minimally interrupted high-quality chest compressions, early defibrillation, discourages endotracheal intubation and encourages use of the bag-valve-mask (BVM) and/or blind-insertion airway device (BIAD) with a ventilation rate of 8-10 breaths/min to minimize hyperventilation. Widespread incorporation of TFCPR in North Carolina (NC) EMS agencies began in 2011, yet its impact on outcomes is unknown. To determine whether TFCPR improves survival with good neurological outcome in out-of-hospital cardiac arrest (OHCA) patients compared to standard CPR. This retrospective cohort analysis of NC EMS agencies reporting data to the Cardiac Arrest Registry for Enhanced Survival (CARES) database from January 2010 to June 2014 included adult, non-traumatic OHCA with presumed cardiac etiology where EMS performed CPR or patient received defibrillation. Exclusions were arrest terminated per EMS policy or DNR. EMS agencies self-reported the TFCPR implementation dates. Patients were categorized as receiving either TFCPR or standard CPR. The primary outcome was good neurologic outcome at time of hospital discharge defined as Pittsburgh Cerebral Performance Category (CPC) 1-2. Of 14,994 OHCAs, 14,129 patients were included for analysis with a mean age 65 (IQR 50-81) years, 61% male, 7.3% with good neurologic outcome, 24.3% with shockable initial rhythm, and 71.5% receiving TFCPR. Of the 3427 (24.3%) with an initial shockable rhythm, 739 (71.9%) had a good neurological outcome. Good neurologic outcome was higher with TFCPR [836 (8.3%, 95%CI 7.7-8.8%)] vs. standard CPR [193 (4.8%, 95%CI 4.2-5.5%)]. Logistic regression controlling for demographic and arrest characteristics revealed TFCPR (OR 1.5), witnessed arrest (OR 4.3), initial shockable rhythm (OR 7.1), and in-hospital hypothermia (OR 3.3) were associated with good neurologic outcome. Mechanical CPR device (OR 0.68), CPR

  17. CPR in the nursing home: fool's errand or looming dilemma?

    LENUS (Irish Health Repository)

    Lyons, D

    2011-09-01

    The indications for CPR (cardiopulmonary resuscitation) have expanded greatly since the technique was introduced and theoretically it can be attempted on all prior to death. Policy initiatives (such as the British Medical Association\\/Royal College of Nursing guidelines) have attempted to provide a clinical rationale for the withholding of inappropriate CPR. Traditionally a care home was felt to be an inappropriate environment to attempt CPR but increased use of advance directives may bring the issue to the fore in this setting.

  18. Association between oxidative stress index and post-CPR early mortality in cardiac arrest patients: A prospective observational study.

    Science.gov (United States)

    Yücel, Hasan; Türkdoğan, Kenan Ahmet; Zorlu, Ali; Aydın, Hüseyin; Kurt, Recep; Yılmaz, Mehmet Birhan

    2015-09-01

    Cardiopulmonary resuscitation (CPR) is a series of lifesaving actions that improve the chance of survival following cardiac arrest (CA). Many clinical and laboratory parameters, such as the presence of asystole, out-of-hospital CPR, and duration of cardiac arrest, are associated with failed CPR in patients with CA. Asystole is a state of no cardiac electrical activity, along with the absence of contractions of the myocardium and absence of cardiac output. Oxidative stress index (OSI), which is the ratio of total oxidative status to total antioxidant status, increases by ischemia-reperfusion injury. We investigated whether OSI levels in patients with CA could predict early mortality after CPR. This study has a prospective observational cohort design. Five patients with a history of cancer, four patients who developed hemolysis in their blood, six patients who were transferred to our hospital from other hospitals, and six patients in whom blood samples for OSI could not be stored properly were excluded. Finally, a total of 90 in-hospital or out-of-hospital CA patients and 40 age- and sex-matched healthy volunteers as the control group were evaluated prospectively. The patients were classified according to the CPR response into a successful group (n=46) and a failed group (n=44). Comparisons between groups were performed using one-way ANOVA with post hoc analysis by Tukey's HSD or independent samples t-test and the Kruskal-Wallis tests or Mann- Whitney U test for normally and abnormally distributed data, respectively. Also, we used chi-square test, Spearman's correlation test, univariate and multible logistic regression analyses, and receiver operator characteristic curve analysis. OSI was 3.0±4.0, 5.6±4.3, and 8.7±3.8 in the control group, the successful CPR group, and the failed CPR group, respectively (pOSI on admission, ischemia-modified albumin, presence of asystole, mean duration of cardiac arrest, out-of-hospital CPR, pH, and potassium and sodium levels were

  19. Polar and non-polar organic aerosols from large-scale agricultural-waste burning emissions in Northern India: Implications to organic mass-to-organic carbon ratio.

    Science.gov (United States)

    Rajput, Prashant; Sarin, M M

    2014-05-01

    This study focuses on characteristics of organic aerosols (polar and non-polar) and total organic mass-to-organic carbon ratio (OM/OC) from post-harvest agricultural-waste (paddy- and wheat-residue) burning emissions in Northern India. Aerosol samples from an upwind location (Patiala: 30.2°N, 76.3°E) in the Indo-Gangetic Plain were analyzed for non-polar and polar fractions of organic carbon (OC1 and OC2) and their respective mass (OM1 and OM2). On average, polar organic aerosols (OM2) contribute nearly 85% of the total organic mass (OM) from the paddy- and wheat-residue burning emissions. The water-soluble-OC (WSOC) to OC2 ratio, within the analytical uncertainty, is close to 1 from both paddy- and wheat-residue burning emissions. However, temporal variability and relatively low WSOC/OC2 ratio (Av: 0.67±0.06) is attributed to high moisture content and poor combustion efficiency during paddy-residue burning, indicating significant contribution (∼30%) of aromatic carbon to OC2. The OM/OC ratio for non-polar (OM1/OC1∼1.2) and polar organic aerosols (OM2/OC2∼2.2), hitherto unknown for open agricultural-waste burning emissions, is documented in this study. The total OM/OC ratio is nearly identical, 1.9±0.2 and 1.8±0.2, from paddy- and wheat-residue burning emissions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Neonatal Acid-Base Status in Fetuses with Abnormal Vertebro- and Cerebro-Placental Ratios.

    Science.gov (United States)

    Morales-Roselló, José; Khalil, Asma; Ferri-Folch, Blanca; Perales-Marín, Alfredo

    2015-01-01

    A low cerebro-placental ratio (CPR) at term suggests the existence of failure to reach growth potential (FRGP) with a higher risk of poor neonatal acid-base status. This study aimed to evaluate whether similar findings were also seen in the vertebral artery (vertebro-placental ratio, VPR), supplying 30% of the cerebral flow. We studied term fetuses classified into groups according to birth weight (BW), CPR and VPR. BW was expressed in centiles and ratios in multiples of the median (MoM). Subsequently, associations with neonatal pH values were evaluated by means of regression curves and Mann-Whitney tests. VPR MoM correlated with BW centiles (p < 0.0001, R2 = 0.042) and its distribution resembled that of CPR MoM (p < 0.001). When both arteries were compared, adequate-for-gestational-age (AGA) fetuses with either low CPR or low VPR had lower neonatal venous pH values (p < 0.05, p < 0.01, respectively). However, in case of small-for-gestational-age (SGA) fetuses, only those with low VPR had significantly lower neonatal arterial and venous pH values (p < 0.05). Blood flow in the vertebral artery mimics that in the middle cerebral artery supporting the FRGP model. Both CPR and VPR identify AGA fetuses with lower neonatal pH values, but only VPR identifies SGA with lower pH values. Hypoxemia might be reflected as a generalized cerebral vasodilation demonstrated as low CPR and VPR.

  1. Animation-assisted CPRII program as a reminder tool in achieving effective one-person-CPR performance.

    Science.gov (United States)

    Choa, Minhong; Cho, Junho; Choi, Young Hwan; Kim, Seungho; Sung, Ji Min; Chung, Hyun Soo

    2009-06-01

    The objective of this study is to compare the skill retention of two groups of lay persons, six months after their last CPR training. The intervention group was provided with animation-assisted CPRII (AA-CPRII) instruction on their cellular phones, and the control group had nothing but what they learned from their previous training. This study was a single blind randomized controlled trial. The participants' last CPR trainings were held at least six months ago. We revised our CPR animation for on-site CPR instruction content emphasizing importance of chest compression. Participants were randomized into two groups, the AA-CPRII group (n=42) and the control group (n=38). Both groups performed three cycles of CPR and their performances were video recorded. These video clips were assessed by three evaluators using a checklist. The psychomotor skills were evaluated using the ResusciAnne SkillReporter. Using the 30-point scoring checklist, the AA-CPRII group had a significantly better score compared to the control group (pCPR could be used as a reminder tool in achieving effective one-person-CPR performance. By installing the CPR instruction on cellular phones and having taught them CPR with it during the training enabled participants to perform better CPR.

  2. CPR Instruction in U.S. High Schools: What Is the State in the Nation?

    Science.gov (United States)

    Brown, Lorrel E; Lynes, Carlos; Carroll, Travis; Halperin, Henry

    2017-11-28

    Cardiopulmonary resuscitation (CPR) training in high schools is required by law in the majority of U.S. states. However, laws differ from state to state, and it is unknown how this legislation is being enacted. The authors sent a cross-sectional, closed survey to educational superintendents in 32 states with CPR laws in June 2016. The authors subsequently performed direct examination and categorization of CPR legislation in 39 states (several states passed legislation as of September 2017). Survey results indicated differing practices with regard to CPR instruction in areas such as course content (63% perform automated external defibrillator training), instructor (47% used CPR-certified teachers/coaches, 30% used other CPR-certified instructors, 11% used noncertified teachers/coaches), and method (7% followed American Red Cross methods, 55% followed American Heart Association methods). CPR laws differ, although almost all (97%) require hands-on training. Although hands-on practice during CPR instruction in high school is required by law in the majority of U.S. states, there is currently no standardized method of implementation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Pay It Forward: High School Video-based Instruction Can Disseminate CPR Knowledge in Priority Neighborhoods

    Science.gov (United States)

    Han, Josiah; Cano, Alejandra; Ramirez, Victor; Morales, Gabriel; Campbell, Teri L.; Hoek, Terry Vanden

    2018-01-01

    Introduction The implementation of creative new strategies to increase layperson cardiopulmonary resuscitation (CPR) and defibrillation may improve resuscitation in priority populations. As more communities implement laws requiring CPR training in high schools, there is potential for a multiplier effect and reach into priority communities with low bystander-CPR rates. Methods We investigated the feasibility, knowledge acquisition, and dissemination of a high school-centered, CPR video self-instruction program with a “pay-it-forward” component in a low-income, urban, predominantly Black neighborhood in Chicago, Illinois with historically low bystander-CPR rates. Ninth and tenth graders followed a video self-instruction kit in a classroom setting to learn CPR. As homework, students were required to use the training kit to “pay it forward” and teach CPR to their friends and family. We administered pre- and post-intervention knowledge surveys to measure knowledge acquisition among classroom and “pay-it-forward” participants. Results Seventy-one classroom participants trained 347 of their friends and family, for an average of 4.9 additional persons trained per kit. Classroom CPR knowledge survey scores increased from 58% to 93% (p CPR educational intervention with a “pay-it-forward” component can disseminate CPR knowledge beyond the classroom. Because schools are centrally-organized settings to which all children and their families have access, school-based interventions allow for a broad reach that encompasses all segments of the population and have potential to decrease disparities in bystander CPR provision. PMID:29560076

  4. Comparing three CPR feedback devices and standard BLS in a single rescuer scenario: a randomised simulation study.

    Science.gov (United States)

    Zapletal, Bernhard; Greif, Robert; Stumpf, Dominik; Nierscher, Franz Josef; Frantal, Sophie; Haugk, Moritz; Ruetzler, Kurt; Schlimp, Christoph; Fischer, Henrik

    2014-04-01

    Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. In this open, prospective, randomised, controlled trial we compared three CPR feedback devices (PocketCPR, CPRmeter, iPhone app PocketCPR) with standard BLS without feedback in a simulated scenario. 240 trained medical students performed single rescuer BLS on a manikin for 8min. Effective compression (compressions with correct depth, pressure point and sufficient decompression) as well as compression rate, flow time fraction and ventilation parameters were compared between the four groups. Study participants using the PocketCPR performed 17±19% effective compressions compared to 32±28% with CPRmeter, 25±27% with the iPhone app PocketCPR, and 35±30% applying standard BLS (PocketCPR vs. CPRmeter p=0.007, PocketCPR vs. standard BLS p=0.001, others: ns). PocketCPR and CPRmeter prevented a decline in effective compression over time, but overall performance in the PocketCPR group was considerably inferior to standard BLS. Compression depth and rate were within the range recommended in the guidelines in all groups. While we found differences between the investigated CPR feedback devices, overall BLS quality was suboptimal in all groups. Surprisingly, effective compression was not improved by any CPR feedback device compared to standard BLS. All feedback devices caused substantial delay in starting CPR, which may worsen outcome. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Keep pushing! Limiting interruptions to CPR; bag-valve mask versus ...

    African Journals Online (AJOL)

    This has led to first responders and paramedics performing single rescuer CPR using a bag-valve-mask (BVM) device as opposed to the historical practice of intubating and ventilating via an endotracheal tube. Bag-valve-mask ventilations, especially during single rescuer CPR, are however associated with complications ...

  6. Effects of diaspirin cross-linked hemoglobin (DCLHb) during and post-CPR in swine.

    Science.gov (United States)

    Chow, M S; Fan, C; Tran, H; Zhao, H; Zhou, L

    2001-04-01

    The purpose of the study was to test the hypothesis that diaspirin cross-linked hemoglobin (DCLHb) can produce improved resuscitation during cardiac arrest. DCLHb, a derivative of human hemoglobin, has previously been demonstrated to produce a vasopressor response that is associated with increased blood flow to vital organs. In addition, it is an oxygen carrier. These effects may be beneficial to extreme low flow states, such as that during cardiac arrest and cardiopulmonary resuscitation (CPR). Experimental cardiac arrest and CPR were carried out in 32 anesthetized immature pigs. In each animal, ventricular fibrillation was induced for 5 min, followed by 10 min of standard CPR with a pneumatic device and room air ventilation. High (15 ml/kg) and low (5 ml/kg) doses of DCLHb or equivalent volume of normal saline were infused at the beginning of CPR in a random and blind manner. Cardiac output, organ blood flow, aortic pressure, coronary perfusion pressure, blood gases, and lactate concentrations were obtained before and during CPR. Following the 10-min CPR, the animals were defibrillated and the return of spontaneous circulation (ROSC) determined. DCLHb treatment achieved 75% ROSC compared with 25% in the saline group (p CPR significantly improves ROSC. This is most likely related to its improvement in coronary perfusion and myocardial oxygen delivery.

  7. Cloud Statistics and Discrimination in the Polar Regions

    Science.gov (United States)

    Chan, M.; Comiso, J. C.

    2012-12-01

    Despite their important role in the climate system, cloud cover and their statistics are poorly known, especially in the polar regions, where clouds are difficult to discriminate from snow covered surfaces. The advent of the A-train, which included Aqua/MODIS, CALIPSO/CALIOP and CloudSat/CPR sensors has provided an opportunity to improve our ability to accurately characterize the cloud cover. MODIS provides global coverage at a relatively good temporal and spatial resolution while CALIOP and CPR provide limited nadir sampling but accurate characterization of the vertical structure and phase of the cloud cover. Over the polar regions, cloud detection from a passive sensors like MODIS is challenging because of the presence of cold and highly reflective surfaces such as snow, sea-ice, glaciers, and ice-sheet, which have surface signatures similar to those of clouds. On the other hand, active sensors such as CALIOP and CPR are not only very sensitive to the presence of clouds but can also provide information about its microphysical characteristics. However, these nadir-looking sensors have sparse spatial coverage and their global data can have data spatial gaps of up to 100 km. We developed a polar cloud detection system for MODIS that is trained using collocated data from CALIOP and CPR. In particular, we employ a machine learning system that reads the radiative profile observed by MODIS and determine whether the field of view is cloudy or clear. Results have shown that the improved cloud detection scheme performs better than typical cloud mask algorithms using a validation data set not used for training. A one-year data set was generated and results indicate that daytime cloud detection accuracies improved from 80.1% to 92.6% (over sea-ice) and 71.2% to 87.4% (over ice-sheet) with CALIOP data used as the baseline. Significant improvements are also observed during nighttime, where cloud detection accuracies increase by 19.8% (over sea-ice) and 11.6% (over ice

  8. Pay It Forward: High School Video-based Instruction Can Disseminate CPR Knowledge in Priority Neighborhoods.

    Science.gov (United States)

    Del Rios, Marina; Han, Josiah; Cano, Alejandra; Ramirez, Victor; Morales, Gabriel; Campbell, Teri L; Hoek, Terry Vanden

    2018-03-01

    The implementation of creative new strategies to increase layperson cardiopulmonary resuscitation (CPR) and defibrillation may improve resuscitation in priority populations. As more communities implement laws requiring CPR training in high schools, there is potential for a multiplier effect and reach into priority communities with low bystander-CPR rates. We investigated the feasibility, knowledge acquisition, and dissemination of a high school-centered, CPR video self-instruction program with a "pay-it-forward" component in a low-income, urban, predominantly Black neighborhood in Chicago, Illinois with historically low bystander-CPR rates. Ninth and tenth graders followed a video self-instruction kit in a classroom setting to learn CPR. As homework, students were required to use the training kit to "pay it forward" and teach CPR to their friends and family. We administered pre- and post-intervention knowledge surveys to measure knowledge acquisition among classroom and "pay-it-forward" participants. Seventy-one classroom participants trained 347 of their friends and family, for an average of 4.9 additional persons trained per kit. Classroom CPR knowledge survey scores increased from 58% to 93% (p pay-it-forward cohort saw an increase from 58% to 82% (p pay-it-forward" component can disseminate CPR knowledge beyond the classroom. Because schools are centrally-organized settings to which all children and their families have access, school-based interventions allow for a broad reach that encompasses all segments of the population and have potential to decrease disparities in bystander CPR provision.

  9. Pay It Forward: High School Video-based Instruction Can Disseminate CPR Knowledge in Priority Neighborhoods

    Directory of Open Access Journals (Sweden)

    Josiah Han

    2018-02-01

    Full Text Available Introduction: The implementation of creative new strategies to increase layperson cardiopulmonary resuscitation (CPR and defibrillation may improve resuscitation in priority populations. As more communities implement laws requiring CPR training in high schools, there is potential for a multiplier effect and reach into priority communities with low bystander-CPR rates. Methods: We investigated the feasibility, knowledge acquisition, and dissemination of a high school-centered, CPR video self-instruction program with a “pay-it-forward” component in a low-income, urban, predominantly Black neighborhood in Chicago, Illinois with historically low bystander-CPR rates. Ninth and tenth graders followed a video self-instruction kit in a classroom setting to learn CPR. As homework, students were required to use the training kit to “pay it forward” and teach CPR to their friends and family. We administered pre- and post-intervention knowledge surveys to measure knowledge acquisition among classroom and “pay-it-forward” participants. Results: Seventy-one classroom participants trained 347 of their friends and family, for an average of 4.9 additional persons trained per kit. Classroom CPR knowledge survey scores increased from 58% to 93% (p < 0.0001. The pay-it-forward cohort saw an increase from 58% to 82% (p < 0.0001. Conclusion: A high school-centered, CPR educational intervention with a “pay-it-forward” component can disseminate CPR knowledge beyond the classroom. Because schools are centrally-organized settings to which all children and their families have access, school-based interventions allow for a broad reach that encompasses all segments of the population and have potential to decrease disparities in bystander CPR provision.

  10. Comparison of CPR1000 and AP1000 rod position indication systems

    International Nuclear Information System (INIS)

    Lei Qing

    2009-01-01

    This paper introduces the structure, the function, the digital detection principle of reactor control rod position and monitoring systems in CPR1000 and AP1000, comparing with the characteristics of the system design. The results show that the operation mode and function of AP1000 Rod position indication system are similar to that of CPR1000, but AP1000 rod position system provides higher reliability, and reduces the numbers of containment electrical penetrations and is with better characteristics than that of CPR1000, since it incorporated the redundancy design and data communication. (authors)

  11. Guidelines for CPR Training in Louisiana Schools. Bulletin No. 1638.

    Science.gov (United States)

    Louisiana State Dept. of Education, Baton Rouge.

    Completion of a course in cardiopulmonary resuscitation (CPR) is required for graduation from high school in Louisiana. This bulletin presents the guidelines for a course in CPR and was prepared with the cooperation of the American Red Cross (ARC) and the American Heart Association (AHA). At the conclusion of the course, students will be prepared…

  12. A heuristic application of critical power ratio to pressurized water reactor core design

    International Nuclear Information System (INIS)

    Ahn, Seung Hoon; Jeun, Gyoo Dong

    2002-01-01

    The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR correlation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large

  13. A high extinction ratio THz polarizer fabricated by double-bilayer wire grid structure

    Science.gov (United States)

    Lu, Bin; Wang, Haitao; Shen, Jun; Yang, Jun; Mao, Hongyan; Xia, Liangping; Zhang, Weiguo; Wang, Guodong; Peng, Xiao-Yu; Wang, Deqiang

    2016-02-01

    We designed a new style of broadband terahertz (THz) polarizer with double-bilayer wire grid structure by fabricating them on both sides of silicon substrate. This THz polarizer shows a high average extinction ratio of 60dB in 0.5 to 2.0 THz frequency range and the maximum of 87 dB at 1.06 THz, which is much higher than that of conventional monolayer wire grid polarizers and single-bilayer wire grid ones.

  14. A high extinction ratio THz polarizer fabricated by double-bilayer wire grid structure

    Directory of Open Access Journals (Sweden)

    Bin Lu

    2016-02-01

    Full Text Available We designed a new style of broadband terahertz (THz polarizer with double-bilayer wire grid structure by fabricating them on both sides of silicon substrate. This THz polarizer shows a high average extinction ratio of 60dB in 0.5 to 2.0 THz frequency range and the maximum of 87 dB at 1.06 THz, which is much higher than that of conventional monolayer wire grid polarizers and single-bilayer wire grid ones.

  15. Arabidopsis CPR5 regulates ethylene signaling via molecular association with the ETR1 receptor.

    Science.gov (United States)

    Wang, Feifei; Wang, Lijuan; Qiao, Longfei; Chen, Jiacai; Pappa, Maria Belen; Pei, Haixia; Zhang, Tao; Chang, Caren; Dong, Chun-Hai

    2017-11-01

    The plant hormone ethylene plays various functions in plant growth, development and response to environmental stress. Ethylene is perceived by membrane-bound ethylene receptors, and among the homologous receptors in Arabidopsis, the ETR1 ethylene receptor plays a major role. The present study provides evidence demonstrating that Arabidopsis CPR5 functions as a novel ETR1 receptor-interacting protein in regulating ethylene response and signaling. Yeast split ubiquitin assays and bi-fluorescence complementation studies in plant cells indicated that CPR5 directly interacts with the ETR1 receptor. Genetic analyses indicated that mutant alleles of cpr5 can suppress ethylene insensitivity in both etr1-1 and etr1-2, but not in other dominant ethylene receptor mutants. Overexpression of Arabidopsis CPR5 either in transgenic Arabidopsis plants, or ectopically in tobacco, significantly enhanced ethylene sensitivity. These findings indicate that CPR5 plays a critical role in regulating ethylene signaling. CPR5 is localized to endomembrane structures and the nucleus, and is involved in various regulatory pathways, including pathogenesis, leaf senescence, and spontaneous cell death. This study provides evidence for a novel regulatory function played by CPR5 in the ethylene receptor signaling pathway in Arabidopsis. © 2017 Institute of Botany, Chinese Academy of Sciences.

  16. Assessment of in-vessel corium retention in CPR1000

    International Nuclear Information System (INIS)

    Chen Xing; Zhang Shishun; Lin Jiming

    2011-01-01

    The In-Vessel corium Retention (IVR) strategy of Chinese 1000 MW class commercial pressurized water reactor (CPR1000) is assessed by Risk-Oriented Accident Analysis Methodology (ROAAM). Four representative severe accident scenarios are selected for the IVR assessment in this paper. According to four representative severe accident scenarios consequence calculated by the deterministic code combined with engineering judgment, the input probability distribution of the assessment is determined. Success probability of IVR from the viewpoint of thermal failure is then predicted using MOPOL code. MOPOL is a code developed basing on the well known ROAAM frame and heat transfer model of corium. It is demonstrated that the success probability of IVR by Reactor Cavity Flooding in CPR1000 is potentially higher than 99%. Application of IVR strategy in CPR1000 is envisioned probable if a further more comprehensive risk-benefit evaluation conclusion is positive. (authors)

  17. Brief compression-only cardiopulmonary resuscitation training video and simulation with homemade mannequin improves CPR skills.

    Science.gov (United States)

    Wanner, Gregory K; Osborne, Arayel; Greene, Charlotte H

    2016-11-29

    Cardiopulmonary resuscitation (CPR) training has traditionally involved classroom-based courses or, more recently, home-based video self-instruction. These methods typically require preparation and purchase fee; which can dissuade many potential bystanders from receiving training. This study aimed to evaluate the effectiveness of teaching compression-only CPR to previously untrained individuals using our 6-min online CPR training video and skills practice on a homemade mannequin, reproduced by viewers with commonly available items (towel, toilet paper roll, t-shirt). Participants viewed the training video and practiced with the homemade mannequin. This was a parallel-design study with pre and post training evaluations of CPR skills (compression rate, depth, hand position, release), and hands-off time (time without compressions). CPR skills were evaluated using a sensor-equipped mannequin and two blinded CPR experts observed testing of participants. Twenty-four participants were included: 12 never-trained and 12 currently certified in CPR. Comparing pre and post training, the never-trained group had improvements in average compression rate per minute (64.3 to 103.9, p = 0.006), compressions with correct hand position in 1 min (8.3 to 54.3, p = 0.002), and correct compression release in 1 min (21.2 to 76.3, p 100/min), but an improved number of compressions with correct release (53.5 to 94.7, p 50 mm) remained problematic in both groups. Comparisons made between groups indicated significant improvements in compression depth, hand position, and hands-off time in never-trained compared to CPR-certified participants. Inter-rater agreement values were also calculated between the CPR experts and sensor-equipped mannequin. A brief internet-based video coupled with skill practice on a homemade mannequin improved compression-only CPR skills, especially in the previously untrained participants. This training method allows for widespread compression-only CPR

  18. Disparities in Survival with Bystander CPR following Cardiopulmonary Arrest Based on Neighborhood Characteristics

    Directory of Open Access Journals (Sweden)

    Nina Thakkar Rivera

    2016-01-01

    Full Text Available The American Heart Association reports the annual incidence of out-of-hospital cardiopulmonary arrests (OHCA is greater than 300,000 with a survival rate of 9.5%. Bystander cardiopulmonary resuscitation (CPR saves one life for every 30, with a 10% decrease in survival associated with every minute of delay in CPR initiation. Bystander CPR and training vary widely by region. We conducted a retrospective study of 320 persons who suffered OHCA in South Florida over 25 months. Increased survival, overall and with bystander CPR, was seen with increasing income (p=0.05, with a stronger disparity between low- and high-income neighborhoods (p=0.01 and p=0.03, resp.. Survival with bystander CPR was statistically greater in white- versus black-predominant neighborhoods (p=0.04. Increased survival, overall and with bystander CPR, was seen with high- versus low-education neighborhoods (p=0.03. Neighborhoods with more high school age persons displayed the lowest survival. We discovered a significant disparity in OHCA survival within neighborhoods of low-income, black-predominance, and low-education. Reduced survival was seen in neighborhoods with larger populations of high school students. This group is a potential target for training, and instruction can conceivably change survival outcomes in these neighborhoods, closing the gap, thus improving survival for all.

  19. Metronome improves compression and ventilation rates during CPR on a manikin in a randomized trial.

    Science.gov (United States)

    Kern, Karl B; Stickney, Ronald E; Gallison, Leanne; Smith, Robert E

    2010-02-01

    We hypothesized that a unique tock and voice metronome could prevent both suboptimal chest compression rates and hyperventilation. A prospective, randomized, parallel design study involving 34 pairs of paid firefighter/emergency medical technicians (EMTs) performing two-rescuer CPR using a Laerdal SkillReporter Resusci Anne manikin with and without metronome guidance was performed. Each CPR session consisted of 2 min of 30:2 CPR with an unsecured airway, then 4 min of CPR with a secured airway (continuous compressions at 100 min(-1) with 8-10 ventilations/min), repeated after the rescuers switched roles. The metronome provided "tock" prompts for compressions, transition prompts between compressions and ventilations, and a spoken "ventilate" prompt. During CPR with a bag/valve/mask the target compression rate of 90-110 min(-1) was achieved in 5/34 CPR sessions (15%) for the control group and 34/34 sessions (100%) for the metronome group (pmetronome or control group during CPR with a bag/valve/mask. During CPR with a bag/endotracheal tube, the target of both a compression rate of 90-110 min(-1) and a ventilation rate of 8-11 min(-1) was achieved in 3/34 CPR sessions (9%) for the control group and 33/34 sessions (97%) for the metronome group (pMetronome use with the secured airway scenario significantly decreased the incidence of over-ventilation (11/34 EMT pairs vs. 0/34 EMT pairs; pmetronome was effective at directing correct chest compression and ventilation rates both before and after intubation. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  20. The G_E/G_M-ratio of the proton by recoil polarization measurement in e+parrow e'+p

    Science.gov (United States)

    Punjabi, Vina; Jones, Mark; Perdrisat, Charles F.; Quemener, Gilles

    1998-10-01

    The recently commissioned Hall A high resolution spectrometers (HRS) and the focal plane polarimeter (FPP) were used to obtain the ratio of the electric and magnetic form factors of the proton, G_E/G_M. This form factor ratio is proportional to the measured ratio of the transverse, P_t, to longitudinal, P_l, components of the recoiling proton polarization. The method takes advantage of the precession of the proton magnetic moment in the hadron HRS, which rotates the longitudinal polarization component into the plane of the FPP analyzer; this allows simultaneous measurement of both components of the polarization. The ratio P_t/P_l is independent of both the electron beam polarization and the polarimeter analyzing power. Most of the data were obtained with polarized beams of 100 μ A with polarization of ~ 0.39 incident on the 15 cm cell of the high power LH2 target. We will report the results for G_E/GM at several values of Q^2 between 0.5 and 3.5 GeV^2.

  1. CPR - child (1 to 8 years old)

    Science.gov (United States)

    Rescue breathing and chest compressions - child; Resuscitation - cardiopulmonary - child; Cardiopulmonary resuscitation - child ... take care of children should learn infant and child CPR if they have not already. See www. ...

  2. Ratios of helicity amplitudes for exclusive ρ0 electroproduction on transversely polarized proton

    Directory of Open Access Journals (Sweden)

    Manaenkov Serguei

    2017-01-01

    Full Text Available Exclusive ρ0-meson electroproduction is studied by the HERMES experiment, using the 27.6 GeV longitudinally polarized electron/positron beam of HERA and a transversely polarized hydrogen target, in the kinematic region 1.0 GeV2 < Q2 < 7.0 GeV2, 3.0 GeV < W < 6.3 GeV, and −t′ < 0.4 GeV2. Using an unbinned maximum-likelihood method, 25 parameters are extracted. They determine the real and imaginary parts of the ratios of certain helicity amplitudes describing ρ0-meson production by a virtual photon, where the denominator is the dominant amplitude F012012${F_{0{1 \\over 2}}}_{0{1 \\over 2}}$. The latter is the nucleon-helicity-non-flip amplitude, which describes the production of a longitudinal ρ0 meson by a longitudinal virtual photon. The transverse target polarization allows for the first time the extraction of ratios of a number of nucleon-helicity-flip amplitudes to F012012${F_{0{1 \\over 2}}}_{0{1 \\over 2}}$. The ratios of nucleon-helicity-non-flip amplitudes are found to be in good agreement with those from the previous HERMES analysis.

  3. Human c-peptide immunoreactivity (CPR) in blood and urine - evaluation of a radioimmunoassay method and its clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kuzuya, T; Matsuda, A; Saito, T; Yoshida, S

    1976-01-01

    A double-antibody radioimmunoassay method, using synthetic human connecting peptide as an immunizing antigen and standard, was evaluated for clinical assay of blood and urine samples. Normal fasting blood connecting peptide immunoreacivity (CPR) was 2.45 +- 0.96 ng/ml, increasing promptly after a 50 g oral glucose load, but somewhat slower than insulin. Molar concentration of CPR exceeded that of insulin. CPR responses to glucose were subnormal in diabetics, very low in juvenile-type cases, and often poor in patients on insulin treatment. Fasting CPR levels were elevated in patients on corticosteroid treatment and with uraemia. A patient with insulin 'auto-antibody' had high serum CPR. A considerable amount of CPR appeared in urine. Normal daily excretion of CPR was 1.52 +- 0.55 ..mu..g/kg or 55.1 +- 18.2 ng/mg creatinine. Urine CPR was very low in juvenile-type diabetics, and elevated in patients on corticosteroid treatment. The results confirm that blood and urine CPR are useful measures of the endocrine pancreatic function.

  4. Ratios of helicity amplitudes for exclusive ρ{sup 0} electroproduction on transversely polarized protons

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Justus-Liebig Universitaet Giessen, II. Physikalisches Institut, Giessen (Germany); University of Michigan, Randall Laboratory of Physics, Ann Arbor, MI (United States); Akopov, N.; Elbakian, G.; Gharibyan, V.; Marukyan, H.; Petrosyan, A. [Yerevan Physics Institute, Yerevan (Armenia); Akopov, Z.; Borissov, A.; Deconinck, W.; Holler, Y.; Rostomyan, A.; Zihlmann, B. [DESY, Hamburg (Germany); Aschenauer, E.C.; Nowak, W.D. [DESY, Zeuthen (Germany); Augustyniak, W.; Marianski, B.; Trzcinski, A.; Zupranski, P. [National Centre for Nuclear Research, Warsaw (Poland); Belostotski, S.; Kisselev, A.; Manaenkov, S.I.; Veretennikov, D.; Vikhrov, V. [B.P. Konstantinov Petersburg Nuclear Physics Institute, Leningrad Region (Russian Federation); Blok, H.P. [National Institute for Subatomic Physics (Nikhef), Amsterdam (Netherlands); VU University, Department of Physics and Astronomy, Amsterdam (Netherlands); Bryzgalov, V.; Ivanilov, A.; Korotkov, V.; Salomatin, Y. [Institute for High Energy Physics, Moscow Region (Russian Federation); Capitani, G.P.; De Sanctis, E.; Muccifora, V.; Reolon, A.R. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, Frascati (Italy); Ciullo, G.; Lenisa, P.; Pappalardo, L.L.; Statera, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara, Ferrara (Italy); Universita di Ferrara, Dipartimento di Fisica e Scienze della Terra, Ferrara (Italy); Contalbrigo, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara, Ferrara (Italy); De Leo, R.; Lagamba, L.; Vilardi, I. [Istituto Nazionale di Fisica Nucleare, Sezione di Bari, Bari (Italy); Dueren, M. [Justus-Liebig Universitaet Giessen, II. Physikalisches Institut, Giessen (Germany); Ellinghaus, F. [University of Colorado, Nuclear Physics Laboratory, Boulder, CO (United States); Felawka, L. [TRIUMF, Vancouver, BC (Canada); Frullani, S.; Garibaldi, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Gruppo Collegato Sanita, Rome (Italy); Istituto Superiore di Sanita, Rome (Italy); Gavrilov, G. [DESY, Hamburg (Germany); B.P. Konstantinov Petersburg Nuclear Physics Institute, Leningrad Region (Russian Federation); TRIUMF, Vancouver, BC (Canada); Goloskokov, S.V.; Shutov, V. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Jackson, H.E.; Reimer, P.E. [Argonne National Laboratory, Physics Division, Argonne, IL (United States); Joosten, S. [Ghent University, Department of Physics and Astronomy, Gent (Belgium); University of Illinois, Department of Physics, Urbana, IL (United States); Kaiser, R.; Lehmann, I.; Rosner, G.; Seitz, B. [University of Glasgow, SUPA, School of Physics and Astronomy, Glasgow (United Kingdom); Karyan, G. [DESY, Hamburg (Germany); Yerevan Physics Institute, Yerevan (Armenia); Kozlov, V.; Terkulov, A. [Lebedev Physical Institute, Moscow (Russian Federation); Kravchenko, P. [Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erlangen (Germany); B.P. Konstantinov Petersburg Nuclear Physics Institute, Leningrad Region (Russian Federation); Kroll, P.; Schaefer, A. [Universitaet Regensburg, Institut fuer Theoretische Physik, Regensburg (Germany); Lapikas, L. [National Institute for Subatomic Physics (Nikhef), Amsterdam (Netherlands); Lorenzon, W. [University of Michigan, Randall Laboratory of Physics, Ann Arbor, MI (United States); Miyachi, Y.; Shibata, T.A. [Tokyo Institute of Technology, Department of Physics, Tokyo (Japan); Movsisyan, A. [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara, Ferrara (Italy); Yerevan Physics Institute, Yerevan (Armenia); Nass, A.; Rith, K. [Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erlangen (Germany); Riedl, C. [DESY, Zeuthen (Germany); University of Illinois, Department of Physics, Urbana, IL (United States); Ryckbosch, D.; Tytgat, M.; Haarlem, Y. van [Ghent University, Department of Physics and Astronomy, Gent (Belgium); Schnell, G. [University of the Basque Country UPV/EHU, Department of Theoretical Physics, Bilbao (Spain); Basque Foundation for Science, IKERBASQUE, Bilbao (Spain); Ghent University, Department of Physics and Astronomy, Gent (Belgium); Truty, R. [University of Illinois, Department of Physics, Urbana, IL (United States); Hulse, C. van [University of the Basque Country UPV/EHU, Department of Theoretical Physics, Bilbao (Spain); Ghent University, Department of Physics and Astronomy, Gent (Belgium); Yaschenko, S. [DESY, Hamburg (Germany); Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erlangen (Germany); Collaboration: The HERMES Collaboration

    2017-06-15

    Exclusive ρ{sup 0}-meson electroproduction is studied by the HERMES experiment, using the 27.6 GeV longitudinally polarized electron/positron beam of HERA and a transversely polarized hydrogen target, in the kinematic region 1.0 GeV{sup 2} < Q{sup 2} < 7.0 GeV{sup 2}, 3.0 GeV < W < 6.3 GeV, and -t{sup '} < 0.4 GeV{sup 2}. Using an unbinned maximum-likelihood method, 25 parameters are extracted. These determine the real and imaginary parts of the ratios of several helicity amplitudes describing ρ{sup 0}-meson production by a virtual photon. The denominator of those ratios is the dominant amplitude, the nucleon-helicity-non-flip amplitude F{sub 0(1)/(2)0(1)/(2)}, which describes the production of a longitudinal ρ{sup 0}-meson by a longitudinal virtual photon. The ratios of nucleon-helicity-non-flip amplitudes are found to be in good agreement with those from the previous HERMES analysis. The transverse target polarization allows for the first time the extraction of ratios of a number of nucleon-helicity-flip amplitudes to F{sub 0(1)/(2)0(1)/(2)}. Results obtained in a handbag approach based on generalized parton distributions taking into account the contribution from pion exchange are found to be in good agreement with these ratios. Within the model, the data favor a positive sign for the π - ρ transition form factor. By also exploiting the longitudinal beam polarization, a total of 71 ρ{sup 0} spin-density matrix elements is determined from the extracted 25 parameters, in contrast to only 53 elements as directly determined in earlier analyses. (orig.)

  5. Ratios of helicity amplitudes for exclusive ρ{sup 0} electroproduction on transversely polarized protons

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Giessen Univ. (Germany). 2. Physikalisches Inst.; Michigan Univ., Ann Arbor, MI (United States). Randall Lab. of Physics; Akopov, N. [Yerevan Physics Institute (Armenia); Akopov, Z. [DESY, Hamburg (Germany); Collaboration: HERMES Collaboration; and others

    2017-06-13

    Exclusive ρ{sup 0}-meson electroproduction is studied by the HERMES experiment, using the 27.6 GeV longitudinally polarized electron/positron beam of HERA and a transversely polarized hydrogen target, in the kinematic region 1.0 GeV{sup 2}ratios of several helicity amplitudes describing ρ{sup 0}-meson production by a virtual photon. The denominator of those ratios is the dominant amplitude, the nucleon-helicity-non-flip amplitude F{sub 0(1)/(2)0(1)/(2)}, which describes the production of a longitudinal ρ{sup 0}-meson by a longitudinal virtual photon. The ratios of nucleon-helicity-non-flip amplitudes are found to be in good agreement with those from the previous HERMES analysis. The transverse target polarization allows for the first time the extraction of ratios of a number of nucleon-helicity-flip amplitudes to F{sub 0(1)/(2)0(1)/(2)}. Results obtained in a handbag approach based on generalized parton distributions taking into account the contribution from pion exchange are found to be in good agreement with these ratios. Within the model, the data favor a positive sign for the π-ρ transition form factor. By also exploiting the longitudinal beam polarization, a total of 71 ρ{sup 0} spin-density matrix elements is determined from the extracted 25 parameters, in contrast to only 53 elements as directly determined in earlier analyses.

  6. Mobile-phone dispatch of laypersons for CPR in out-of-hospital cardiac arrest.

    Science.gov (United States)

    Ringh, Mattias; Rosenqvist, Mårten; Hollenberg, Jacob; Jonsson, Martin; Fredman, David; Nordberg, Per; Järnbert-Pettersson, Hans; Hasselqvist-Ax, Ingela; Riva, Gabriel; Svensson, Leif

    2015-06-11

    Cardiopulmonary resuscitation (CPR) performed by bystanders is associated with increased survival rates among persons with out-of-hospital cardiac arrest. We investigated whether rates of bystander-initiated CPR could be increased with the use of a mobile-phone positioning system that could instantly locate mobile-phone users and dispatch lay volunteers who were trained in CPR to a patient nearby with out-of-hospital cardiac arrest. We conducted a blinded, randomized, controlled trial in Stockholm from April 2012 through December 2013. A mobile-phone positioning system that was activated when ambulance, fire, and police services were dispatched was used to locate trained volunteers who were within 500 m of patients with out-of-hospital cardiac arrest; volunteers were then dispatched to the patients (the intervention group) or not dispatched to them (the control group). The primary outcome was bystander-initiated CPR before the arrival of ambulance, fire, and police services. A total of 5989 lay volunteers who were trained in CPR were recruited initially, and overall 9828 were recruited during the study. The mobile-phone positioning system was activated in 667 out-of-hospital cardiac arrests: 46% (306 patients) in the intervention group and 54% (361 patients) in the control group. The rate of bystander-initiated CPR was 62% (188 of 305 patients) in the intervention group and 48% (172 of 360 patients) in the control group (absolute difference for intervention vs. control, 14 percentage points; 95% confidence interval, 6 to 21; PCPR was associated with significantly increased rates of bystander-initiated CPR among persons with out-of-hospital cardiac arrest. (Funded by the Swedish Heart-Lung Foundation and Stockholm County; ClinicalTrials.gov number, NCT01789554.).

  7. Simple CPR: A randomized, controlled trial of video self-instructional cardiopulmonary resuscitation training in an African American church congregation.

    Science.gov (United States)

    Todd, K H; Heron, S L; Thompson, M; Dennis, R; O'Connor, J; Kellermann, A L

    1999-12-01

    Despite the proven efficacy of cardiopulmonary resuscitation (CPR), only a small fraction of the population knows how to perform it. As a result, rates of bystander CPR and rates of survival from cardiac arrest are low. Bystander CPR is particularly uncommon in the African American community. Successful development of a simplified approach to CPR training could boost rates of bystander CPR and save lives. We conducted the following randomized, controlled study to determine whether video self-instruction (VSI) in CPR results in comparable or better performance than traditional CPR training. This randomized, controlled trial was conducted among congregational volunteers in an African American church in Atlanta, GA. Subjects were randomly assigned to receive either 34 minutes of VSI or the 4-hour American Heart Association "Heartsaver" CPR course. Two months after training, blinded observers used explicit criteria to assess CPR performance in a simulated cardiac arrest setting. A recording manikin was used to measure ventilation and chest compression characteristics. Participants also completed a written test of CPR-related knowledge and attitudes. VSI trainees displayed a comparable level of performance to that achieved by traditional trainees. Observers scored 40% of VSI trainees competent or better in performing CPR, compared with only 16% of traditional trainees (absolute difference 24%, 95% confidence interval 8% to 40%). Data from the recording manikin confirmed these observations. VSI trainees and traditional trainees achieved comparable scores on tests of CPR-related knowledge and attitudes. Thirty-four minutes of VSI can produce CPR of comparable quality to that achieved by traditional training methods. VSI provides a simple, quick, consistent, and inexpensive alternative to traditional CPR instruction, and may be used to extend CPR training to historically underserved populations.

  8. Prediction of Recovery from Coma After CPR

    Science.gov (United States)

    ... to pain. There is good evidence* that myoclonus status epilepticus within the first day after CPR accurately predicts poor recovery from coma. Myoclonus status epilepticus is a constant twitching of muscles, including the ...

  9. Rescuer fatigue under the 2010 ERC guidelines, and its effect on cardiopulmonary resuscitation (CPR) performance.

    Science.gov (United States)

    McDonald, Catherine H; Heggie, James; Jones, Christopher M; Thorne, Christopher J; Hulme, Jonathan

    2013-08-01

    Updated life-support guidelines were published by the European Resuscitation Council (ERC) in 2010, increasing the required depth and rate of chest compression delivery. This study sought to determine the impact of these guidelines on rescuer fatigue and cardiopulmonary resuscitation (CPR) performance. 62 Health science students performed 5 min of conventional CPR in accordance with the 2010 ERC guidelines. A SkillReporter manikin was used to objectively assess temporal change in determinants of CPR quality. Participants subjectively reported their end-fatigue levels, using a visual analogue scale, and the point at which they believed fatigue was affecting CPR delivery. 49 (79%) participants reported that fatigue affected their CPR performance, at an average of 167 s. End fatigue averaged 49.5/100 (range 0-95). The proportion of chest compressions delivered correctly decreased from 52% in min 1 to 39% in min 5, approaching significance (p=0.071). A significant decline in chest compressions reaching the recommended depth occurred between the first (53%) and fifth (38%) min (p=0.012). Almost half this decline (6%) was between the first and second minutes of CPR. Neither chest compression rate, nor rescue breath volume, were affected by rescuer fatigue. Fatigue affects chest compression delivery within the second minute of CPR under the 2010 ERC guidelines, and is poorly judged by rescuers. Rescuers should, therefore, be encouraged to interchange after 2 min of CPR delivery. Team leaders should be advised to not rely on rescuers to self-report fatigue, and should, instead, monitor for its effects.

  10. Polarization ratio property and material classification method in passive millimeter wave polarimetric imaging

    Science.gov (United States)

    Cheng, Yayun; Qi, Bo; Liu, Siyuan; Hu, Fei; Gui, Liangqi; Peng, Xiaohui

    2016-10-01

    Polarimetric measurements can provide additional information as compared to unpolarized ones. In this paper, linear polarization ratio (LPR) is created to be a feature discriminator. The LPR properties of several materials are investigated using Fresnel theory. The theoretical results show that LPR is sensitive to the material type (metal or dielectric). Then a linear polarization ratio-based (LPR-based) method is presented to distinguish between metal and dielectric materials. In order to apply this method to practical applications, the optimal range of incident angle have been discussed. The typical outdoor experiments including various objects such as aluminum plate, grass, concrete, soil and wood, have been conducted to validate the presented classification method.

  11. Does the sex of a simulated patient affect CPR?

    Science.gov (United States)

    Kramer, Chelsea E; Wilkins, Matthew S; Davies, Jan M; Caird, Jeff K; Hallihan, Gregory M

    2015-01-01

    While males and females are equally at risk of sudden cardiac arrest (SCA), females are less likely to be resuscitated. Cardiopulmonary Resuscitation (CPR) may be inhibited by socio-cultural norms about exposing female victims' chests. Empirically confirming this hypothesis is limited by lack of patient simulators modeling realistic female physiques. A commercially-available patient simulator was transformed to evaluate how physical attributes of a patient's sex might influence lay participants who were asked to resuscitate a female versus a male during simulated cardiac arrest. Sixty-nine participants consented to be in the study. Participants were randomly assigned to provide CPR and defibrillation as instructed by a commercially-available automated external defibrillator on a patient simulator presented as either a male or female experiencing cardiac arrest. Rescuers removed significantly more clothing from the male than the female, with men removing less clothing from the female. More rescuers' initial hand placements for CPR were centered between the female's breasts compared to the male, on which placement was distributed across the chest towards the nipples. While rescuers had better hand placement for CPR on the female, both men and women rescuers were reluctant to remove the female's clothing, with men significantly more hesitant. Reticence to remove clothing was often articulated relative to social norms during structured interviews. We suggest that using only male simulators will not allow trainees to experience social differences associated with the care of a female simulated patient. Realistic female patient simulators are needed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. Effect of bystander CPR initiation prior to the emergency call on ROSC and 30day survival-An evaluation of 548 emergency calls.

    Science.gov (United States)

    Viereck, Søren; Palsgaard Møller, Thea; Kjær Ersbøll, Annette; Folke, Fredrik; Lippert, Freddy

    2017-02-01

    This study aimed at evaluating if time for initiation of bystander cardiopulmonary resuscitation (CPR) - prior to the emergency call (CPR prior ) versus during the emergency call following dispatcher-assisted CPR (CPR during ) - was associated with return of spontaneous circulation (ROSC) and 30-day survival. The secondary aim was to identify predictors of CPR prior . This observational study evaluated out-of-hospital cardiac arrests (OHCA) occurring in the Capital Region of Denmark from 01.01.2013 to 31.12.2013. OHCAs were linked to emergency medical dispatch centre records and corresponding emergency calls were evaluated. Multivariable logistic regression analyses were applied to evaluate the association between time for initiation of bystander CPR, ROSC, and 30-day survival. Univariable logistic regression analyses were applied to identify predictors of CPR prior . The study included 548 emergency calls for OHCA patients receiving bystander CPR, 34.9% (n=191) in the CPR prior group and 65.1% (n=357) in the CPR during group. Multivariable analyses showed no difference in ROSC (OR=0.88, 95% CI: 0.56-1.38) or 30-day survival (OR=1.14, 95% CI: 0.68-1.92) between CPR prior and CPR during . Predictors positively associated with CPR prior included witnessed OHCA and healthcare professional bystanders. Predictors negatively associated with CPR prior included residential location, solitary bystanders, and bystanders related to the patient. The majority of bystander CPR (65%) was initiated during the emergency call, following dispatcher-assisted CPR instructions. Whether bystander CPR was initiated prior to emergency call versus during the emergency call following dispatcher-assisted CPR was not associated with ROSC or 30-day survival. Dispatcher-assisted CPR was especially beneficial for the initiation of bystander CPR in residential areas. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  13. Implementation of a mechanical CPR device in a physician staffed HEMS - a prospective observational study.

    Science.gov (United States)

    Rauch, Simon; Strapazzon, Giacomo; Brodmann, Monika; Fop, Ernst; Masoner, Christian; Rauch, Lydia; Forti, Alessandro; Pietsch, Urs; Mair, Peter; Brugger, Hermann

    2018-04-28

    In this prospective, observational study we describe the incidence and characteristics of out of hospital cardiac arrest (OHCA) cases who received mechanical CPR, after the implementation of a mechanical CPR device (LUCAS 2; Physio Control, Redmond, WA, USA) in a physician staffed helicopter emergency medical service (HEMS) in South Tyrol, Italy. During the study period (06/2013-04/2016), 525 OHCA cases were registered by the dispatch centre, 271 (51.6%) were assisted by HEMS. LUCAS 2 was applied in 18 (6.6%) of all HEMS-assisted OHCA patients; ten were treated with LUCAS 2 at the scene only, and eight were transported to hospital with ongoing CPR. Two (11.1%) of the 18 patients survived long term with full neurologic recovery. In seven of eight patients transferred to hospital with ongoing CPR, CPR was ceased in the emergency room without further intervention. Retrospectively, all HEMS-assisted OHCA cases were screened for proposed indication criteria for prolonged CPR. Thirteen patients fulfilled these criteria, but only two of them were transported to hospital. Based on these results, we propose a standard operating procedure for HEMS-assisted patients with refractory OHCA in a region without hospitals with ECLS capacity.

  14. It isn't like this on TV: Revisiting CPR survival rates depicted on popular TV shows.

    Science.gov (United States)

    Portanova, Jaclyn; Irvine, Krystle; Yi, Jae Yoon; Enguidanos, Susan

    2015-11-01

    Public perceptions of cardiopulmonary resuscitation (CPR) can be influenced by the media. Nearly two decades ago, a study found that the rates of survival following CPR were far higher in popular TV shows than actual rates. In recent years, major strides toward enhanced education and communication around life sustaining interventions have been made. This study aimed to reassess the accuracy of CPR portrayed by popular medical TV shows. Additionally, we sought to determine whether these shows depicted discussions of care preferences and referenced advance directives. Three trained research assistants independently coded two leading medical dramas airing between 2010 and 2011, Grey's Anatomy and House. Patient characteristics, CPR survival rates, and goals of care discussions were recorded. CPR was depicted 46 times in the 91 episodes, with a survival rate of 69.6%. Among those immediately surviving following CPR, the majority (71.9%) survived to hospital discharge and 15.6% died before discharge. Advance directive discussions only occurred for two patients, and preferences regarding code status (8.7%), intubation (6.5%) and feeding (4.3%) rarely occurred. Both popular TV shows portrayed CPR as more effective than actual rates. Overall, the shows portrayed an immediate survival rate nearly twice that of actual survival rates. Inaccurate TV portrayal of CPR survival rates may misinform viewers and influence care decisions made during serious illness and at end of life. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Arabidopsis CPR5 independently regulates seed germination and postgermination arrest of development through LOX pathway and ABA signaling.

    Directory of Open Access Journals (Sweden)

    Guilan Gao

    Full Text Available The phytohormone abscisic acid (ABA and the lipoxygenases (LOXs pathway play important roles in seed germination and seedling growth and development. Here, we reported on the functional characterization of Arabidopsis CPR5 in the ABA signaling and LOX pathways. The cpr5 mutant was hypersensitive to ABA in the seed germination, cotyledon greening and root growth, whereas transgenic plants overexpressing CPR5 were insensitive. Genetic analysis demonstrated that CPR5 gene may be located downstream of the ABI1 in the ABA signaling pathway. However, the cpr5 mutant showed an ABA independent drought-resistant phenotype. It was also found that the cpr5 mutant was hypersensitive to NDGA and NDGA treatment aggravated the ABA-induced delay in the seed germination and cotyledon greening. Taken together, these results suggest that the CPR5 plays a regulatory role in the regulation of seed germination and early seedling growth through ABA and LOX pathways independently.

  16. Brief compression-only cardiopulmonary resuscitation training video and simulation with homemade mannequin improves CPR skills

    OpenAIRE

    Wanner, Gregory K.; Osborne, Arayel; Greene, Charlotte H.

    2016-01-01

    Background Cardiopulmonary resuscitation (CPR) training has traditionally involved classroom-based courses or, more recently, home-based video self-instruction. These methods typically require preparation and purchase fee; which can dissuade many potential bystanders from receiving training. This study aimed to evaluate the effectiveness of teaching compression-only CPR to previously untrained individuals using our 6-min online CPR training video and skills practice on a homemade mannequin, r...

  17. Using a serious game to complement CPR instruction in a nurse faculty.

    Science.gov (United States)

    Boada, Imma; Rodriguez-Benitez, Antonio; Garcia-Gonzalez, Juan Manuel; Olivet, Josep; Carreras, Vicenç; Sbert, Mateu

    2015-11-01

    Cardiopulmonary resuscitation (CPR) is a first aid key survival technique used to stimulate breathing and keep blood flowing to the heart. Its effective administration can significantly increase the chances of survival for victims of cardiac arrest. LISSA is a serious game designed to complement CPR teaching and also to refresh CPR skills in an enjoyable way. The game presents an emergency situation in a 3D virtual environment and the player has to save the victim applying the CPR actions. In this paper, we describe LISSA and its evaluation in a population composed of 109 nursing undergraduate students enrolled in the Nursing degree of our university. To evaluate LISSA we performed a randomized controlled trial that compares the classical teaching methodology, composed of self-directed learning for theory plus laboratory sessions with a mannequin for practice, with the one that uses LISSA after self-directed learning for theory and before laboratory sessions with a mannequin. From our evaluation we observed that students using LISSA (Group 2 and 3) gave significantly better learning acquisition scores than those following traditional classes (Group 1). To evaluate the differences between students of these groups we performed a paired samples t-test between Group 1 and 2 (μ1=35, 67, μ2=47, 50 and pevaluated student performance of main steps of CPR protocol. Students that use LISSA performed better than the ones that did not use it. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Schoolchildren as BLS instructors for relatives and friends: Impact on attitude towards bystander CPR.

    Science.gov (United States)

    Stroobants, Jan; Monsieurs, Koenraad; Devriendt, Bart; Dreezen, Christa; Vets, Philippe; Mols, Pierre

    2014-12-01

    We investigated the impact of Cardio-Pulmonary Resuscitation (CPR) instruction by children on the attitude of people to perform bystander CPR. In 2012, children from primary and secondary school (age span 11–13 years) received a free individual CPR training package containing an inexpensive manikin and a training video. After a CPR training session by their class teacher, they were invited to teach their relatives and friends. After the training, the trainees of the children were invited to participate in a web survey, containing a test and questions about prior CPR training and about their attitude towards bystander CPR (BCPR) before and after the training. We measured the impact on the attitude to perform BCPR and the theoretical knowledge transfer by the children. A total of 4012 training packages were distributed to 72 schools of which 55 class teachers subscribed their students (n = 822) for the training programme for relatives and friends. After a validation procedure, 874 trainees of 290 children were included in the study. In comparison to trainees of secondary schoolchildren, trainees of primary schoolchildren scored better for the test as well as for a positive change of attitude towards future BCPR (P attitude towards BCPR positively. Instructing schoolchildren to teach their relatives and friends in Basic Life Support (BLS) led to a more positive attitude towards BCPR. The results were more positive with trainees from primary schoolchildren than with trainees from secondary schoolchildren.

  19. How to provide around-the-clock CPR certification without losing any sleep.

    Science.gov (United States)

    Umlauf, M G

    1990-01-01

    Teaching and reviewing cardiopulmonary resuscitation (CPR) to employees is an important part of the role and responsibilities of hospital nurse educators. The new teaching technologies of computer-assisted instruction and interactive video have been merged into a teaching/learning system that was tested by a rural federal hospital. Over a 2-month period, more than one third of the hospital's staff members were certified in CPR by the standards of the American Heart Association with the learning system. Ease of operation, employee enthusiasm, and easy access to the equipment were identified as important factors that contributed to the successful implementation of this innovative CPR training/review program. Additional evaluation of the system confirmed that the system was efficient, cost effective, and time-saving.

  20. Analysis of bystander CPR quality during out-of-hospital cardiac arrest using data derived from automated external defibrillators.

    Science.gov (United States)

    Fernando, Shannon M; Vaillancourt, Christian; Morrow, Stanley; Stiell, Ian G

    2018-07-01

    Little is known regarding the quality of cardiopulmonary resuscitation (CPR) performed by bystanders in out-of-hospital cardiac arrest (OHCA). We sought to determine quality of bystander CPR provided during OHCA using CPR quality data stored by Automated External Defibrillators (AEDs). We used the Resuscitation Outcomes Consortium database to identify OHCA cases of presumed cardiac etiology where an AED was utilized. We then matched AED data to each case identified. AED data was analyzed using manufacturer software in order to determine overall measures of bystander CPR quality, changes in bystander CPR quality over time, and adherence to existing 2010 Resuscitation Quality Guidelines. 100 cases of OHCA of presumed cardiac etiology involving bystander CPR and with corresponding AED data. Mean age was 62.3 years, and 75% were male. Bystanders demonstrated high-quality CPR over all minutes of resuscitation, with a chest compression fraction of 76%, a compression depth of 5.3 cm, and a compression rate of 111.2 compressions/min. Mean perishock pause was 26.8 s. Adherence rates to 2010 Resuscitation Guidelines for compression rate and depth were found to be 66% and 55%, respectively. CPR quality was lowest in the first minute, resulting from increased delay to rhythm analysis (mean 40.7 s). In cases involving shock delivery, latency from initiation of AED to shock delivery was 59.2 s. We found that bystanders perform high-quality CPR, with strong adherence rates to existing Resuscitation Guidelines. High-quality CPR is maintained over the first five minutes of resuscitation, but was lowest in the first minute. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. The Plant Immunity Regulating F-Box Protein CPR1 Supports Plastid Function in Absence of Pathogens

    Directory of Open Access Journals (Sweden)

    Christiane Hedtmann

    2017-09-01

    Full Text Available The redox imbalanced 6 mutant (rimb6 of Arabidopsis thaliana was isolated in a genetic screening approach for mutants with defects in chloroplast-to-nucleus redox signaling. It has an atypically low activation status of the 2-Cys peroxiredoxin-A promoter in the seedling stage. rimb6 shows wildtype-like germination, seedling development and greening, but slower growth and reduced biomass in the rosette stage. Mapping of the casual mutation revealed that rimb6 carries a single nucleotide polymorphism in the gene encoding CONSTITUTIVE EXPRESSER OF PATHOGENESIS RELATED (PR GENES 1, CPR1 (At4g12560, leading to a premature stop codon. CPR1 is known as a repressor of pathogen signaling and regulator of microtubule organization. Allelism of rimb6 and cpr1 revealed a function of CPR1 in chloroplast stress protection. Expression studies in pathogen signaling mutants demonstrated that CPR1-mediated activation of genes for photosynthesis and chloroplast antioxidant protection is, in contrast to activation of pathogen responses, regulated independently from PAD4-controlled salicylic acid (SA accumulation. We conclude that the support of plastid function is a basic, SA-independent function of CPR1.

  2. Metronome Use for Coordination of Breaths and Cardiac Compressions Delivered by Minimally-Trained Caregivers During Two-Person CPR

    Science.gov (United States)

    Hurst, Victor, IV; West, Sarah; Austin, Paul; Branson, Richard; Beck, George

    2005-01-01

    Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training over 18 months before each mission, including two-person cardiopulmonary resuscitation (2CPR) as recommended by the American Heart Association (AHA). Recent studies have concluded that the use of metronomic tones improves the coordination of 2CPR by trained clinicians. 2CPR performance data for minimally-trained caregivers has been limited. The goal of this study was to determine whether use of a metronome by minimally-trained caregivers (CMO analogues) would improve 2CPR performance. 20 pairs of minimally-trained caregivers certified in 2CPR via AHA guidelines performed 2CPR for 4 minutes on an instrumented manikin using 3 interventions: 1) Standard 2CPR without a metronome [NONE], 2) Standard 2CPR plus a metronome for coordinating compression rate only [MET], 3) Standard 2CPR plus a metronome for coordinating both the compression rate and ventilation rate [BOTH]. Caregivers were evaluated for their ability to meet the AHA guideline of 32 breaths-240 compressions in 4 minutes. All (100%) caregivers using the BOTH intervention provided the required number of ventilation breaths as compared with the NONE caregivers (10%) and MET caregivers (0%). For compressions, 97.5% of the BOTH caregivers were not successful in meeting the AHA compression guideline; however, an average of 238 compressions of the desired 240 were completed. None of the caregivers were successful in meeting the compression guideline using the NONE and MET interventions. This study demonstrates that use of metronomic tones by minimally-trained caregivers for coordinating both compressions and breaths improves 2CPR performance. Meeting the breath guideline is important to minimize air entering the stomach, thus decreasing the likelihood of gastric aspiration. These results suggest that manifesting a metronome for the ISS may augment the performance of 2CPR on orbit and thus may

  3. Use of whole body CT to detect patterns of CPR-related injuries after sudden cardiac arrest.

    Science.gov (United States)

    Dunham, Gregor M; Perez-Girbes, Alexandre; Bolster, Ferdia; Sheehan, Kellie; Linnau, Ken F

    2017-11-09

    We have recently implemented a dedicated sudden cardiac arrest (SCA) - whole-body computed tomography (WBCT) protocol to evaluate SCA patients with return of spontaneous circulation (ROSC) following cardiopulmonary resuscitation (CPR). The aim of this study is to evaluate the number and pattern of CPR-related injuries in ROSC patients with SCA-WBCT. Single-centre retrospective review of 39 patients (13 female; 20 male, mean age 51.8 years) with non-traumatic, out-of-hospital SCA and ROSC and evaluation with dedicated SCA-WBCT over a 10-month period. In-hospital mortality was 54%. CPR-related injuries were detected in 85% (33/39). Chest injuries were most common on WBCT: 85% (33) subjects had rib fractures (mean of 8.5 fractures/subject); 31% (12) sternal fractures; 13% (5) mediastinal haematoma; 10% (4) pneumothorax; 8% (3) pneumomediastinum and 3% (1) haemothorax. Three subjects (8%) had abdominal injuries on WBCT, including one hepatic haematoma with active haemorrhage. CPR-related injuries on WBCT after ROSC are common, with serial rib fractures detected most commonly. An unexpectedly high rate of abdominal injuries was detected on SCA-WBCT. Radiologists need to be attuned to the spectrum of CPR-related injuries in WBCT, including abdominal injuries and subtle rib fractures. • CPR frequently causes injuries. • Radiologists should be aware of the spectrum of CPR related injuries. • Rib fractures are frequent and radiologic findings often subtle. • Clinically unexpected abdominal injuries may be present.

  4. 77 FR 74278 - Proposed Information Collection (Internet Student CPR Web Registration Application); Comment Request

    Science.gov (United States)

    2012-12-13

    ... (Internet Student CPR Web Registration Application); Comment Request AGENCY: Veterans Health Administration.... Title: Internet Student CPR Web Registration Application, VA Form 10-0468. OMB Control Number: 2900-0746... Minneapolis VA Medical Center Education Service. Students will be able to identify and register for a training...

  5. Use of impedance threshold device in conjunction with our novel adhesive glove device for ACD-CPR does not result in additional chest decompression.

    Science.gov (United States)

    Shih, Andre; Udassi, Sharda; Porvasnik, Stacy L; Lamb, Melissa A; Badugu, Srinivasarao; Venkata, Giridhar Kaliki; Lopez-Colon, Dalia; Haque, Ikram U; Zaritsky, Arno L; Udassi, Jai P

    2013-10-01

    To evaluate the hemodynamic effects of using an adhesive glove device (AGD) to perform active compression-decompression CPR (AGD-CPR) in conjunction with an impedance threshold device (ITD) in a pediatric cardiac arrest model. Controlled, randomized animal study. In this study, 18 piglets were anesthetized, ventilated, and continuously monitored. After 3min of untreated ventricular fibrillation, animals were randomized (6/group) to receive either standard CPR (S-CPR), active compression-decompression CPR via adhesive glove device (AGD-CPR) or AGD-CPR along with an ITD (AGD-CPR+ITD) for 2min at 100-120compressions/min. AGD is delivered using a fingerless leather glove with a Velcro patch on the palmer aspect and the counter Velcro patch adhered to the pig's chest. Data (mean±SD) were analyzed using one-way ANOVA with pair wise multiple comparisons to assess differences between groups. p-Value≤0.05 was considered significant. Both AGD-CPR and AGD-CPR+ITD groups produced lower intrathoracic pressure (IttP, mmHg) during decompression phase (-13.4±6.7, p=0.01 and -11.9±6.5, p=0.01, respectively) in comparison to S-CPR (-0.3±4.2). Carotid blood flow (CBF, % of baseline mL/min) was higher in AGD-CPR and AGD-CPR+ITD (respectively 64.3±47.3%, p=0.03 and 67.5±33.1%, p=0.04) as compared with S-CPR (29.1±12.5%). Coronary perfusion pressure (CPP, mmHg) was higher in AGD-CPR and AGD-CPR+ITD (respectively 19.7±4.6, p=0.04 and 25.6±12.1, p=0.02) when compared to S-CPR (9.6±9.1). There was no statistically significant difference between AGD-CPR and AGD-CPR+ITD groups with reference to intra-thoracic pressure, carotid blood flow and coronary perfusion pressure. Active compression decompression delivered by this simple and inexpensive adhesive glove device resulted in improved cerebral blood flow and coronary perfusion pressure. There was no statistically significant added effect of ITD use along with AGD-CPR on the decompression of the chest. Copyright © 2013 Elsevier

  6. Effect of one-rescuer compression/ventilation ratios on cardiopulmonary resuscitation in infant, pediatric, and adult manikins.

    Science.gov (United States)

    Srikantan, Shoba Krishnan; Berg, Robert A; Cox, Tim; Tice, Lisa; Nadkarni, Vinay M

    2005-05-01

    Optimal chest compression to ventilation ratio (C:V) for one-rescuer cardiopulmonary resuscitation (CPR) is not known, with current American Heart Association recommendations 3:1 for newborns, 5:1 for children, and 15:2 for adults. C:V ratios influence effectiveness of CPR, but memorizing different ratios is educationally cumbersome. We hypothesized that a 10:2 ratio might provide adequate universal application for all age arrest victims. Clinical study. Tertiary care children's hospital. Thirty-five health care providers. Thirty-five health care providers performed 5-min epochs of one-rescuer CPR at C:V ratios of 3:1, 5:1, 10:2, and 15:2 in random order on infant, pediatric, and adult manikins. Compressions were paced at 100/min by metronome. The number of effective compressions and ventilations delivered per minute was recorded by a trained basic life support instructor. Subjective assessments of fatigue (self-report) and exertion (change in rescuer pulse rate compared with baseline) were assessed. Analysis was by repeated measures analysis of variance and paired Student's t-test. Effective infant compressions per minute did not differ by C:V ratio, but ventilations per minute were greater at 3:1 vs. 5:1, 10:2, and 15:2 (p 15:2 (p educational value and technique retention.

  7. Hospital implementation of resuscitation guidelines and review of CPR training programmes: a nationwide study.

    Science.gov (United States)

    Schmidt, Anders S; Lauridsen, Kasper G; Adelborg, Kasper; Løfgren, Bo

    2016-06-01

    This study aimed to investigate cardiopulmonary resuscitation (CPR) guideline implementation and CPR training in hospitals. This nationwide study included mandatory resuscitation protocols from each Danish hospital. Protocols were systematically reviewed for adherence to the European Resuscitation Council (ERC) 2010 guidelines and CPR training in each hospital. Data were included from 45 of 47 hospitals. Adherence to the ERC basic life support (BLS) algorithm was 49%, whereas 63 and 58% of hospitals adhered to the recommended chest compression depth and rate. Adherence to the ERC advanced life support (ALS) algorithm was 81%. Hospital BLS course duration was [median (interquartile range)] 2.3 (1.5-2.5) h, whereas ALS course duration was 4.0 (2.5-8.0) h. Implementation of ERC 2010 guidelines on BLS is limited in Danish hospitals 2 years after guideline publication, whereas the majority of hospitals adhere to the ALS algorithm. CPR training differs among hospitals.

  8. Production of a highly active, soluble form of the cytochrome P450 reductase (CPR A) from Candida tropicalis

    Science.gov (United States)

    Donnelly, Mark

    2006-08-01

    The present invention provides soluble cytochrome p450 reductase (CPR) proteins from Candida sp. having an altered N-terminal region which results in reduced hydrophobicity of the N-terminal region. Also provided are host cells comprising the subject soluble CPR proteins. In addition, the present invention provides nucleotide and corresponding amino acid sequences for soluble CPR proteins and vectors comprising the nucleotide sequences. Methods for producing a soluble CPR, for increasing production of a dicarboxylic acid, and for detecting a cytochrome P450 are also provided.

  9. Wavelength dependence of interstellar polarization and ratio of total to selective extinction

    International Nuclear Information System (INIS)

    Serkowski, K.; Mathewson, D.S.; Ford, V.L.

    1975-01-01

    Wavelength dependence of interstellar linear polarization has been observed for about 180 stars, mostly southern, in the UBVR spectral regions. A multichannel polarimeter-photometer, in which spectral regions are separated by dichroic filters, was used. Normalized wavelength dependence of interstellar linear polarization p follows closely a single empirical curve p (lambda)/p /sub max/=exp-1.15 ln 2 (lambda/sub max//lambda), where the wavelength lambda/sub max/ at which the maximum interstellar linear polarization p/sub max/ occurs takes values from 0.45 μ to 0.8 μ. Wavelength lambda/sub max/ is well correlated with the ratios of color excesses E/sub V-K//E/sub B-V/, E/sub V-K//E/sub V-R/, and E/sub V-I//E/sub V-R/. These correlations indicate that the ratio R of total to selective interstellar extinction can be found for any individual star from the relationship R = 5.5 lambda/sub max/. Polarimetry seems to be the most practical method of estimating R. A map of distribution of lambda/sub max/ on the sky, based on values for about 350 stars, indicates several well defined regions with lambda/sub max/, and hence R, clearly larger (or smaller) than the median value lambda/sub max/ = π.545 μ, corresponding to R = 3.0. The predominance of larger than average values of lambda/sub max/ among stars nearer than 0.4 kpc and the negative correlation between lambda/sub max/ and E/sub B-V/ are explained by selection effects. There is evidence of negative correlation between lambda/sub max/ and p/sub max//E/sub B-V/ suggested by Kruszewski. The lower limits for color excess of Praesepe, M67, and several globular clusters are set by their linear polarization. The largest known values of interstellar circular polarization, parallel q parallel approximately equal to 0.06 percent, were found in near-infrared for two stars with exceptionally small lambda/sub max/: star No. 12 in association VI Cygni and HD 204827. (U.S.)

  10. Significantly improved surface morphology of N-polar GaN film grown on SiC substrate by the optimization of V/III ratio

    Science.gov (United States)

    Deng, Gaoqiang; Zhang, Yuantao; Yu, Ye; Yan, Long; Li, Pengchong; Han, Xu; Chen, Liang; Zhao, Degang; Du, Guotong

    2018-04-01

    In this paper, N-polar GaN films with different V/III ratios were grown on vicinal C-face SiC substrates by metalorganic chemical vapor deposition. During the growth of N-polar GaN film, the V/III ratio was controlled by adjusting the molar flow rate of ammonia while keeping the trimethylgallium flow rate unchanged. The influence of the V/III ratio on the surface morphology of N-polar GaN film has been studied. We find that the surface root mean square roughness of N-polar GaN film over an area of 20 × 20 μm2 can be reduced from 8.13 to 2.78 nm by optimization of the V/III ratio. Then, using the same growth conditions, N-polar InGaN/GaN multiple quantum wells (MQWs) light-emitting diodes (LEDs) were grown on the rough and the smooth N-polar GaN templates, respectively. Compared with the LED grown on the rough N-polar GaN template, dramatically improved interface sharpness and luminescence uniformity of the InGaN/GaN MQWs are achieved for the LED grown on the smooth N-polar GaN template.

  11. The impact of CPR and AED training on healthcare professionals' self-perceived attitudes to performing resuscitation

    Directory of Open Access Journals (Sweden)

    Källestedt Marie-Louise

    2012-04-01

    Full Text Available Abstract Background Healthcare professionals have shown concern about performing mouth-to-mouth ventilation due to the risks to themselves with the procedure. However, little is known about healthcare professionals' fears and attitudes to start CPR and the impact of training. Objective To examine whether there were any changes in the attitudes among healthcare professionals to performing CPR from before to after training. Methods Healthcare professionals from two Swedish hospitals were asked to answer a questionnaire before and after training. The questions were relating to physical and mental discomfort and attitudes to CPR. Statistical analysis used was generalized McNemar's test. Results Overall, there was significant improvement in 10 of 11 items, reflecting various aspects of attitudes to CPR. All groups of health care professionals (physicians, nurses, assistant nurses, and "others" = physiotherapists, occupational therapists, social welfare officers, psychologists, biomedical analysts felt more secure in CPR knowledge after education. In other aspects, such as anxiety prior to a possible cardiac arrest, only nurses and assistant nurses improved. The concern about being infected, when performing mouth to mouth ventilation, was reduced with the most marked reduction in physicians (75%; P Conclusion In this hospital-based setting, we found a positive outcome of education and training in CPR concerning healthcare professionals' attitudes to perform CPR. They felt more secure in their knowledge of cardiopulmonary resuscitation. In some aspects of attitudes to resuscitation nurses and assistant nurses appeared to be the groups that were most markedly influenced. The concern of being infected by a disease was low.

  12. Fetal cerebro-placental ratio and adverse perinatal outcome: systematic review and meta-analysis of the association and diagnostic performance.

    Science.gov (United States)

    Nassr, Ahmed Abobakr; Abdelmagied, Ahmed M; Shazly, Sherif A M

    2016-03-01

    The objective of this meta-analysis is to assess the value of fetal cerebro-placental Doppler ratio (CPR) in predicting adverse perinatal outcome in pregnancies with fetal growth restriction (FGR). Three databases were used: MEDLINE, EMBASE (with online Ovid interface) and SCOPUS and studies from inception to April 2015 were included. Studies that reported perinatal outcomes of fetuses at risk of FGR or sonographically diagnosed FGR that were evaluated with CPR were considered eligible. Perinatal outcomes include cesarean section (CS) for fetal distress, APGAR scores at 5 min, neonatal complications and admission to neonatal intensive care unit (NICU). Pooled data were expressed as odds ratio (OR) and confidence intervals (CI), and the summary receiver operating characteristic (SROC) curve was used to illustrate the diagnostic accuracy of CPR. Seven studies were eligible (1428 fetuses). Fetuses with abnormal CPR were at higher risk of CS for fetal distress (OR=4.49, 95% CI [1.63, 12.42]), lower APGAR scores (OR=4.01, 95% CI [2.65, 6.08]), admission to NICU (OR=9.65, 95% CI [3.02, 30.85]), and neonatal complications (OR=11.00, 95% [3.64, 15.37]) than fetuses who had normal CPR. These risks were higher among studies that included fetuses diagnosed with FGR than fetuses at risk of FGR. Abnormal CPR had higher diagnostic accuracy for adverse perinatal outcomes among "sonographically diagnosed FGR" studies than "at risk of FGR" studies. Abnormal CPR is associated with substantial risk of adverse perinatal outcomes. The test seems to be particularly useful for follow up of fetuses with sonographically diagnosed FGR.

  13. Quality of cardio-pulmonary resuscitation (CPR) during paediatric resuscitation training: time to stop the blind leading the blind.

    Science.gov (United States)

    Arshid, Muhammad; Lo, Tsz-Yan Milly; Reynolds, Fiona

    2009-05-01

    Recent evidence suggested that the quality of cardio-pulmonary resuscitation (CPR) during adult advanced life support training was suboptimal. This study aimed to assess the CPR quality of a paediatric resuscitation training programme, and to determine whether it was sufficiently addressed by the trainee team leaders during training. CPR quality of 20 consecutive resuscitation scenario training sessions was audited prospectively using a pre-designed proforma. A consultant intensivist and a senior nurse who were also Advanced Paediatric Life Support (APLS) instructors assessed the CPR quality which included ventilation frequency, chest compression rate and depth, and any unnecessary interruption in chest compressions. Team leaders' response to CPR quality and elective change of compression rescuer during training were also recorded. Airway patency was not assessed in 13 sessions while ventilation rate was too fast in 18 sessions. Target compression rate was not achieved in only 1 session. The median chest compression rate was 115 beats/min. Chest compressions were too shallow in 10 sessions and were interrupted unnecessarily in 13 sessions. More than 50% of training sessions did not have elective change of the compression rescuer. 19 team leaders failed to address CPR quality during training despite all team leaders being certified APLS providers. The quality of CPR performance was suboptimal during paediatric resuscitation training and team leaders-in-training had little awareness of this inadequacy. Detailed CPR quality assessment and feedback should be integrated into paediatric resuscitation training to ensure optimal performance in real life resuscitations.

  14. Decarbonylated cyclophilin A Cpr1 protein protects Saccharomyces cerevisiae KNU5377Y when exposed to stress induced by menadione.

    Science.gov (United States)

    Kim, Il-Sup; Jin, Ingnyol; Yoon, Ho-Sung

    2011-01-01

    Cyclophilins are conserved cis-trans peptidyl-prolyl isomerase that are implicated in protein folding and function as molecular chaperones. The accumulation of Cpr1 protein to menadione in Saccharomyces cerevisiae KNU5377Y suggests a possibility that this protein may participate in the mechanism of stress tolerance. Stress response of S. cerevisiae KNU5377Y cpr1Δ mutant strain was investigated in the presence of menadione (MD). The growth ability of the strain was confirmed in an oxidant-supplemented medium, and a relationship was established between diminishing levels of cell rescue enzymes and MD sensitivity. The results demonstrate the significant effect of CPR1 disruption in the cellular growth rate, cell viability and morphology, and redox state in the presence of MD and suggest the possible role of Cpr1p in acquiring sensitivity to MD and its physiological role in cellular stress tolerance. The in vivo importance of Cpr1p for antioxidant-mediated reactive oxygen species (ROS) neutralization and chaperone-mediated protein folding was confirmed by analyzing the expression changes of a variety of cell rescue proteins in a CPR1-disrupted strain. The cpr1Δ to the exogenous MD showed reduced expression level of antioxidant enzymes, molecular chaperones, and metabolic enzymes such as nicotinamide adenine dinucleotide phosphate (NADPH)- or adenosine triphosphate (ATP)-generating systems. More importantly, it was shown that cpr1Δ mutant caused imbalance in the cellular redox homeostasis and increased ROS levels in the cytosol as well as mitochondria and elevated iron concentrations. As a result of excess ROS production, the cpr1Δ mutant provoked an increase in oxidative damage and a reduction in antioxidant activity and free radical scavenger ability. However, there was no difference in the stress responses between the wild-type and the cpr1Δ mutant strains derived from S. cerevisiae BY4741 as a control strain under the same stress. Unlike BY4741, KNU5377Y Cpr1

  15. Functions of standard CPR training on performance qualities of medical volunteers for Mt. Taishan International Mounting Festival.

    Science.gov (United States)

    Fanshan, Meng; Lin, Zhao; Wenqing, Liu; Chunlei, Lu; Yongqiang, Liu; Naiyi, Li

    2013-01-01

    Cardiopulmonary resuscitation (CPR) is a sudden emergency procedure that requires a rapid and efficient response, and personnel training in lifesaving procedures. Regular practice and training are necessary to improve resuscitation skills and reduce anxiety among the staff. As one of the most important skills mastered by medical volunteers serving for Mt. Taishan International Mounting Festival, we randomly selected some of them to evaluate the quality of CPR operation and compared the result with that of the untrained doctors and nurses. In order to evaluate the functions of repeating standard CPR training on performance qualities of medical volunteers for Mt. Taishan International Mounting Festival, their performance qualities of CPR were compared with those of the untrained medical workers working in emergency departments of hospitals in Taian. The CPR performance qualities of 52 medical volunteers (Standard Training Group), who had continually taken part in standard CPR technical training for six months, were tested at random and were compared with those of 68 medical workers (Compared Group) working in emergency departments of hospitals in Taian who hadn't attended CPR training within a year. The QCPR 3535 monitor (provided by Philips Company) was used to measure the standard degree of single simulated CPR performance, including the chest compression depth, frequency, released pressure between compressions and performance time of compression and ventilation, the results of which were recorded in the table and the number of practical compression per minute was calculated. The data were analyzed by x2 Test and t Test. The factors which would influence CPR performance, including gender, age, placement, hand skill, posture of compression and frequency of training, were classified and given parameters, and were put to Logistic repression analysis. The CPR performance qualities of volunteers were much higher than those of the compared group. The overall pass rates

  16. The effect of step stool use and provider height on CPR quality during pediatric cardiac arrest: A simulation-based multicentre study.

    Science.gov (United States)

    Cheng, Adam; Lin, Yiqun; Nadkarni, Vinay; Wan, Brandi; Duff, Jonathan; Brown, Linda; Bhanji, Farhan; Kessler, David; Tofil, Nancy; Hecker, Kent; Hunt, Elizabeth A

    2018-01-01

    We aimed to explore whether a) step stool use is associated with improved cardiopulmonary resuscitation (CPR) quality; b) provider adjusted height is associated with improved CPR quality; and if associations exist, c) determine whether just-in-time (JIT) CPR training and/or CPR visual feedback attenuates the effect of height and/or step stool use on CPR quality. We analysed data from a trial of simulated cardiac arrests with three study arms: No intervention; CPR visual feedback; and JIT CPR training. Step stool use was voluntary. We explored the association between 1) step stool use and CPR quality, and 2) provider adjusted height and CPR quality. Adjusted height was defined as provider height + 23 cm (if step stool was used). Below-average height participants were ≤ gender-specific average height; the remainder were above average height. We assessed for interaction between study arm and both adjusted height and step stool use. One hundred twenty-four subjects participated; 1,230 30-second epochs of CPR were analysed. Step stool use was associated with improved compression depth in below-average (female, p=0.007; male, pstep stool use (pStep stool use is associated with improved compression depth regardless of height. Increased provider height is associated with improved compression depth, with visual feedback attenuating the effects of height and step stool use.

  17. Augmented survival of out-of-hospital cardiac arrest victims with the use of mobile phones for emergency communication under the DA-CPR protocol getting information from callers beside the victim.

    Science.gov (United States)

    Maeda, Tetsuo; Yamashita, Akira; Myojo, Yasuhiro; Wato, Yukihiro; Inaba, Hideo

    2016-10-01

    To investigate the impacts of emergency calls made using mobile phones on the quality of dispatcher-assisted cardiopulmonary resuscitation (DA-CPR) and survival from out-of-hospital cardiac arrests (OHCAs) that were not witnessed by emergency medical service (EMS). In this prospective study, we collected data for 2530 DA-CPR-attempted medical emergency cases (517 using mobile phones and 2013 using landline phones) and 2980 non-EMS-witnessed OHCAs (600 using mobile phones and 2380 using landline phones). Time factors and quality of DA-CPR, backgrounds of callers and outcomes of OHCAs were compared between mobile and landline phone groups. Emergency calls are much more frequently placed beside the arrest victim in mobile phone group (52.7% vs. 17.2%). The positive predictive value and acceptance rate of DA-CPR in mobile phone group (84.7% and 80.6%, respectively) were significantly higher than those in landline group (79.2% and 70.9%). The proportion of good-quality bystander CPR in mobile phone group was significantly higher than that in landline group (53.5% vs. 45.0%). When analysed for all non-EMS-witnessed OHCAs, rates of 1-month survival and 1-year neurologically favourable survival in mobile phone group (7.8% and 3.5%, respectively) were higher than those in landline phone group (4.6% and 1.9%; pmobile phone calls were associated with increased 1-month survival in the subgroup of OHCAs receiving bystander CPR (adjusted odds ratio, 1.84; 95% CI, 1.15-2.92). Emergency calls made using mobile phones are likely to augment the survival from OHCAs by improving DA-CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Regions of High Out-Of-Hospital Cardiac Arrest Incidence and Low Bystander CPR Rates in Victoria, Australia.

    Science.gov (United States)

    Straney, Lahn D; Bray, Janet E; Beck, Ben; Finn, Judith; Bernard, Stephen; Dyson, Kylie; Lijovic, Marijana; Smith, Karen

    2015-01-01

    Out-of-hospital cardiac arrest (OHCA) remains a major public health issue and research has shown that large regional variation in outcomes exists. Of the interventions associated with survival, the provision of bystander CPR is one of the most important modifiable factors. The aim of this study is to identify census areas with high incidence of OHCA and low rates of bystander CPR in Victoria, Australia. We conducted an observational study using prospectively collected population-based OHCA data from the state of Victoria in Australia. Using ArcGIS (ArcMap 10.0), we linked the location of the arrest using the dispatch coordinates (longitude and latitude) to Victorian Local Government Areas (LGAs). We used Bayesian hierarchical models with random effects on each LGA to provide shrunken estimates of the rates of bystander CPR and the incidence rates. Over the study period there were 31,019 adult OHCA attended, of which 21,436 (69.1%) cases were of presumed cardiac etiology. Significant variation in the incidence of OHCA among LGAs was observed. There was a 3 fold difference in the incidence rate between the lowest and highest LGAs, ranging from 38.5 to 115.1 cases per 100,000 person-years. The overall rate of bystander CPR for bystander witnessed OHCAs was 62.4%, with the rate increasing from 56.4% in 2008-2010 to 68.6% in 2010-2013. There was a 25.1% absolute difference in bystander CPR rates between the highest and lowest LGAs. Significant regional variation in OHCA incidence and bystander CPR rates exists throughout Victoria. Regions with high incidence and low bystander CPR participation can be identified and would make suitable targets for interventions to improve CPR participation rates.

  19. Automated cardiopulmonary resuscitation using a load-distributing band external cardiac support device for in-hospital cardiac arrest: a single centre experience of AutoPulse-CPR.

    Science.gov (United States)

    Spiro, J R; White, S; Quinn, N; Gubran, C J; Ludman, P F; Townend, J N; Doshi, S N

    2015-02-01

    Poor quality cardiopulmonary resuscitation (CPR) predicts adverse outcome. During invasive cardiac procedures automated-CPR (A-CPR) may help maintain effective resuscitation. The use of A-CPR following in-hospital cardiac arrest (IHCA) remains poorly described. Firstly, we aimed to assess the efficiency of healthcare staff using A-CPR in a cardiac arrest scenario at baseline, following re-training and over time (Scenario-based training). Secondly, we studied our clinical experience of A-CPR at our institution over a 2-year period, with particular emphasis on the details of invasive cardiac procedures performed, problems encountered, resuscitation rates and in-hospital outcome (AutoPulse-CPR Registry). Scenario-based training: Forty healthcare professionals were assessed. At baseline, time-to-position device was slow (mean 59 (±24) s (range 15-96s)), with the majority (57%) unable to mode-switch. Following re-training time-to-position reduced (28 (±9) s, pCPR Registry: 285 patients suffered IHCA, 25 received A-CPR. Survival to hospital discharge following conventional CPR was 28/260 (11%) and 7/25 (28%) following A-CPR. A-CPR supported invasive procedures in 9 patients, 2 of whom had A-CPR dependant circulation during transfer to the catheter lab. A-CPR may provide excellent haemodynamic support and facilitate simultaneous invasive cardiac procedures. A significant learning curve exists when integrating A-CPR into clinical practice. Further studies are required to better define the role and effectiveness of A-CPR following IHCA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. The use of CPR data in fisheries research

    NARCIS (Netherlands)

    Corten, A.A.H.M.; Lindley, J.A.

    2003-01-01

    The Continuous Plankton Recorder (CPR) survey was initiated partly to contribute to our understanding of the variability of fish stocks and as a potential method for predicting fish distributions from the abundance and composition of the plankton. The latter objective has been superseded by

  1. Communication for Policy Research (CPR) South-South | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    ... of telecom researchers : measures and messages relevant to CPRsouth. Download PDF. Reports. CPRafrica 2010-2012 : a comparative analysis vis-í -vis TPRC, EuroCPR, and CPRsouth/africa. Download PDF. Reports. Communication for Policy Research Africa (CPRafrica) (South-South in contract) : final technical and ...

  2. Evaluation of Cardiopulmonary Resuscitation (CPR) for Patient Outcomes and their Predictors

    Science.gov (United States)

    Singh, Swati; Grewal, Anju; Gautam, Parshotam L; Luthra, Neeru; Tanwar, Gayatri; Kaur, Amarpreet

    2016-01-01

    Introduction Cardiac arrest continues to be a common cause of in-hospital deaths. Even small improvements in survival can translate into thousands of lives saved every year. Aim The aim of our prospective observational study was to elicit the outcomes and predictors of in-hospital cardiopulmonary resuscitation among adult patients. Settings and Design All in-hospital adult patients (age >14) who suffered cardiac arrest & were attended by a Code Blue Team between 1st January 2012 & 30th April 2013 were part of the study. Materials and Methods The cardiopulmonary resuscitation (CPR) was assessed in terms of: Response time, Presenting initial rhythm, Time to first defibrillation, Duration of CPR and Outcome (Return of spontaneous circulation (ROSC), Glasgow outcome scale (GOS) at discharge). Statistical Analysis Age, GOS and mean response time were analysed using t-test and ANOVA. Logistic regression was applied to determine the significance of the various factors in determining mortality. Results ROSC was achieved in 44% of a total of 127 patients included in our study. Asystole/Pulseless electrical activity (PEA) was the most common presenting rhythm (87.5%). The survival to discharge was seen in 7.1% patients of whom only 3.9% patients had good neurological outcome. Regression and survival analysis depicted achievement of ROSC during CPR, absence of co-morbidities and shorter response time of code blue team as predictors of good outcome. Conclusion We found poor outcome of CPR after in-hospital cardiac arrest. This was mainly attributed to an initial presenting rhythm of Asystole/PEA in most cases and delayed response times. PMID:26894150

  3. Accident Analysis of Chinese CPR1000 in Response to Station Blackout

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Juyoul [FNC Technology Co., Yongin (Korea, Republic of); Cilliers, Anthonie [North-West University, Potchefstroom (South Africa)

    2016-10-15

    Stress tests required evaluation of the consequences of loss of safety functions from any initiating event (e.g., earthquake or flooding) causing loss of electrical power, including station blackout (SBO). The SBO scenario involves a loss of offsite power, failure of the redundant emergency diesel generators, failure of alternate current (AC) power restoration and the eventual degradation of the reactor coolant pump (RCP) seals resulting in a long term loss of coolant. Using PCTRAN/CPR1000, this study analyses the station blackout on a Chinese CPR1000 which is the most representative type reactor in terms of number of reactors, operating period, power capacity and geological distance from Korean Peninsula. Both the physical effects of the accidents as well as the releases of radioisotopes are calculated and discussed. Station blackout simulation was conducted in this study. The resulting effects seen are consistent with other stress test station blackout tests used utilizing licensed simulation codes. An exact comparison is however not possible as the plants on which the simulations was done vary greatly and the limitations of availability to Chinese FSAR. PCTRAN/CPR1000 is an extremely useful simulation package that provides engineers and scientists very accurate feedback to how a nuclear power plant would react as a whole under various plant conditions. It is able to do this extremely fast as well. As a training tool PCTRAN/CPR1000 provides hands-on experience with many of the primary plant operations and develops an intuitive understanding of the plant.

  4. Effect of bystander CPR initiation prior to the emergency call on ROSC and 30day survival

    DEFF Research Database (Denmark)

    Viereck, Søren; Palsgaard Møller, Thea; Kjær Ersbøll, Annette

    2017-01-01

    BACKGROUND: This study aimed at evaluating if time for initiation of bystander cardiopulmonary resuscitation (CPR) - prior to the emergency call (CPRprior) versus during the emergency call following dispatcher-assisted CPR (CPRduring) - was associated with return of spontaneous circulation (ROSC...... and corresponding emergency calls were evaluated. Multivariable logistic regression analyses were applied to evaluate the association between time for initiation of bystander CPR, ROSC, and 30-day survival. Univariable logistic regression analyses were applied to identify predictors of CPRprior. RESULTS: The study...... included 548 emergency calls for OHCA patients receiving bystander CPR, 34.9% (n=191) in the CPRpriorgroup and 65.1% (n=357) in the CPRduringgroup. Multivariable analyses showed no difference in ROSC (OR=0.88, 95% CI: 0.56-1.38) or 30-day survival (OR=1.14, 95% CI: 0.68-1.92) between CPRpriorand CPRduring...

  5. Mutation of a cuticular protein, BmorCPR2, alters larval body shape and adaptability in silkworm, Bombyx mori.

    Science.gov (United States)

    Qiao, Liang; Xiong, Gao; Wang, Ri-xin; He, Song-zhen; Chen, Jie; Tong, Xiao-ling; Hu, Hai; Li, Chun-lin; Gai, Ting-ting; Xin, Ya-qun; Liu, Xiao-fan; Chen, Bin; Xiang, Zhong-huai; Lu, Cheng; Dai, Fang-yin

    2014-04-01

    Cuticular proteins (CPs) are crucial components of the insect cuticle. Although numerous genes encoding cuticular proteins have been identified in known insect genomes to date, their functions in maintaining insect body shape and adaptability remain largely unknown. In the current study, positional cloning led to the identification of a gene encoding an RR1-type cuticular protein, BmorCPR2, highly expressed in larval chitin-rich tissues and at the mulberry leaf-eating stages, which is responsible for the silkworm stony mutant. In the Dazao-stony strain, the BmorCPR2 allele is a deletion mutation with significantly lower expression, compared to the wild-type Dazao strain. Dysfunctional BmorCPR2 in the stony mutant lost chitin binding ability, leading to reduced chitin content in larval cuticle, limitation of cuticle extension, abatement of cuticle tensile properties, and aberrant ratio between internodes and intersegmental folds. These variations induce a significant decrease in cuticle capacity to hold the growing internal organs in the larval development process, resulting in whole-body stiffness, tightness, and hardness, bulging intersegmental folds, and serious defects in larval adaptability. To our knowledge, this is the first study to report the corresponding phenotype of stony in insects caused by mutation of RR1-type cuticular protein. Our findings collectively shed light on the specific role of cuticular proteins in maintaining normal larval body shape and will aid in the development of pest control strategies for the management of Lepidoptera.

  6. Rationale, design, and implementation protocol of an electronic health record integrated clinical prediction rule (iCPR randomized trial in primary care

    Directory of Open Access Journals (Sweden)

    Wisnivesky Juan

    2011-09-01

    Full Text Available Abstract Background Clinical prediction rules (CPRs represent well-validated but underutilized evidence-based medicine tools at the point-of-care. To date, an inability to integrate these rules into an electronic health record (EHR has been a major limitation and we are not aware of a study demonstrating the use of CPR's in an ambulatory EHR setting. The integrated clinical prediction rule (iCPR trial integrates two CPR's in an EHR and assesses both the usability and the effect on evidence-based practice in the primary care setting. Methods A multi-disciplinary design team was assembled to develop a prototype iCPR for validated streptococcal pharyngitis and bacterial pneumonia CPRs. The iCPR tool was built as an active Clinical Decision Support (CDS tool that can be triggered by user action during typical workflow. Using the EHR CDS toolkit, the iCPR risk score calculator was linked to tailored ordered sets, documentation, and patient instructions. The team subsequently conducted two levels of 'real world' usability testing with eight providers per group. Usability data were used to refine and create a production tool. Participating primary care providers (n = 149 were randomized and intervention providers were trained in the use of the new iCPR tool. Rates of iCPR tool triggering in the intervention and control (simulated groups are monitored and subsequent use of the various components of the iCPR tool among intervention encounters is also tracked. The primary outcome is the difference in antibiotic prescribing rates (strep and pneumonia iCPR's encounters and chest x-rays (pneumonia iCPR only between intervention and control providers. Discussion Using iterative usability testing and development paired with provider training, the iCPR CDS tool leverages user-centered design principles to overcome pervasive underutilization of EBM and support evidence-based practice at the point-of-care. The ongoing trial will determine if this collaborative

  7. Difference of reactor core nuclear instrument between AP1000 and CPR1000

    International Nuclear Information System (INIS)

    Zhang Shidong; Zhou Can; Deng Tian

    2014-01-01

    As a typical generation Ⅲ reactor technique, the AP1000 applies many advanced design concepts, simplifies the design, reduces equipment quantities, and thus enhances systematic reliability. The comparison of reactor core measurement instrument differences between AP1000 and CPR1000 from several aspects was involved in the paper. Through analysis and comparison of these differences, passive design concepts and characteristics of AP1000 are familiarized, and conveniences for staffs engaged in CPR1000 to learn and grasp AP1000 technique are provided. It is useful in reactor start up, operation and maintenance. (authors)

  8. Cardiopulmonary Re-Immonation (CPR: How Long Should A Person Insist On Performing The Maneuvers?

    Directory of Open Access Journals (Sweden)

    Henrique José Bandeira Formiga

    2017-04-01

    Full Text Available Objetive: The study had the aim to describe the exact moment of interrupting CPR maneuvers in patients in CRP situations. Method: This is an exploratory and descriptive research, with quantitative character and approach. It was performed with 67 (seventy-seven nurses from a Regional Hospital, who were informed about the objectives of the same. There were included those who act in direct patient care; of effective position and contracted in the service; And with more than one (1 year of training. The instrument used for data collection was a questionnaire, previously elaborated, containing objective, subjective and non-inductive questions, which allowed the informant to answer the data pertinent to the study. It was found that the majority of the interviewees were women, aged between 31 and 35 years, specialists, with more than 4 years of training and 3 years of service, medical / surgical clinic attendees, and without reports of training. Results: They demonstrated they know the exact timing of CPR maneuvers but reported that they would not apply CPR in situations in which the patient had cadaveric stiffness, decomposition, crushing of the skull and thorax, or a CPA report of more than 20 minutes. Faced with conditions in which the team could decide not to perform CPR, they reported not applying CPR in the vegetative state, in terminal or chronic patients. Conclusion: Therefore, they conclude that the said moment of interrupting the protocol is determined in a personal and ethical way, that is, by the individuality of each situation. Keywords: Nurses. Cardiovascular Stop. Cardiopulmonary resuscitation.

  9. Reactions and coping strategies in lay rescuers who have provided CPR to out-of-hospital cardiac arrest victims: a qualitative study.

    Science.gov (United States)

    Mathiesen, Wenche Torunn; Bjørshol, Conrad Arnfinn; Braut, Geir Sverre; Søreide, Eldar

    2016-05-25

    Cardiopulmonary resuscitation (CPR) provided by community citizens is of paramount importance for out-of-hospital cardiac arrest (OHCA) victims' survival. Fortunately, CPR rates by community citizens seem to be rising. However, the experience of providing CPR is rarely investigated. The aim of this study was to explore reactions and coping strategies in lay rescuers who have provided CPR to OHCA victims. This is a qualitative study of 20 lay rescuers who have provided CPR to 18 OHCA victims. We used a semistructured interview guide focusing on their experiences after providing CPR. The study was conducted in the Stavanger region of Norway, an area with very high bystander CPR rates. Three themes emerged from the interview analysis: concern, uncertainty and coping strategies. Providing CPR had been emotionally challenging for all lay rescuers and, for some, had consequences in terms of family and work life. Several lay rescuers experienced persistent mental recurrences of the OHCA incident and had concerns about the outcome for the cardiac arrest victim. Unknown or fatal outcomes often caused feelings of guilt and were particularly difficult to handle. Several reported the need to be acknowledged for their CPR attempts. Health-educated lay rescuers seemed to be less affected than others. A common coping strategy was confiding in close relations, preferably the health educated. However, some required professional help to cope with the OHCA incident. Lay rescuers experience emotional and social challenges, and some struggle to cope in life after providing CPR in OHCA incidents. Experiencing a positive patient outcome and being a health-educated lay rescuer seem to mitigate concerns. Common coping strategies are attempts to reduce uncertainty towards patient outcome and own CPR quality. Further studies are needed to determine whether an organised professional follow-up can mitigate the concerns and uncertainty of lay rescuers. Published by the BMJ Publishing Group

  10. Application of Calibrated Peer Review (CPR) Writing Assignments to Enhance Experiments with an Environmental Chemistry Focus

    Science.gov (United States)

    Margerum, Lawrence D.; Gulsrud, Maren; Manlapez, Ronald; Rebong, Rachelle; Love, Austin

    2007-01-01

    The browser-based software program, Calibrated Peer Review (CPR) developed by the Molecular Science Project enables instructors to create structured writing assignments in which students learn by writing and reading for content. Though the CPR project covers only one experiment in general chemistry, it might provide lab instructors with a method…

  11. Corpuls cpr resuscitation device generates superior emulated flows and pressures than LUCAS II in a mechanical thorax model.

    Science.gov (United States)

    Eichhorn, S; Mendoza Garcia, A; Polski, M; Spindler, J; Stroh, A; Heller, M; Lange, R; Krane, M

    2017-06-01

    The provision of sufficient chest compression is among the most important factors influencing patient survival during cardiopulmonary resuscitation (CPR). One approach to optimize the quality of chest compressions is to use mechanical-resuscitation devices. The aim of this study was to compare a new device for chest compression (corpuls cpr) with an established device (LUCAS II). We used a mechanical thorax model consisting of a chest with variable stiffness and an integrated heart chamber which generated blood flow dependent on the compression depth and waveform. The method of blood-flow generation could be changed between direct cardiac-compression mode and thoracic-pump mode. Different chest-stiffness settings and compression modes were tested to generate various blood-flow profiles. Additionally, an endurance test at high stiffness was performed to measure overall performance and compression consistency. Both resuscitation machines were able to compress the model thorax with a frequency of 100/min and a depth of 5 cm, independent of the chosen chest stiffness. Both devices passed the endurance test without difficulty. The corpuls cpr device was able to generate about 10-40% more blood flow than the LUCAS II device, depending on the model settings. In most scenarios, the corpuls cpr device also generated a higher blood pressure than the LUCAS II. The peak compression forces during CPR were about 30% higher using the corpuls cpr device than with the LUCAS II. In this study, the corpuls cpr device had improved blood flow and pressure outcomes than the LUCAS II device. Further examination in an animal model is required to prove the findings of this preliminary study.

  12. CPR performance in the presence of audiovisual feedback or football shoulder pads.

    Science.gov (United States)

    Tanaka, Shota; Rodrigues, Wayne; Sotir, Susan; Sagisaka, Ryo; Tanaka, Hideharu

    2017-01-01

    The initiation of cardiopulmonary resuscitation (CPR) can be complicated by the use of protective equipment in contact sports, and the rate of success in resuscitating the patient depends on the time from incident to start of CPR. The aim of our study was to see if (1) previous training, (2) the presence of audiovisual feedback and (3) the presence of football shoulder pads (FSP) affected the quality of chest compressions. Six basic life support certified athletic training students (BLS-ATS), six basic life support certified emergency medical service personnel (BLS-EMS) and six advanced cardiac life support certified emergency medical service personnel (ACLS-EMS) participated in a crossover manikin study. A quasi-experimental repeated measures design was used to measure the chest compression depth (cm), rate (cpm), depth accuracy (%) and rate accuracy (%) on four different conditions by using feedback and/or FSP. Real CPR Help manufactured by ZOLL (Chelmsford, Massachusetts, USA) was used for the audiovisual feedback. Three participants from each group performed 2 min of chest compressions at baseline first, followed by compressions with FSP, with feedback and with both FSP and feedback (FSP+feedback). The other three participants from each group performed compressions at baseline first, followed by compressions with FSP+feedback, feedback and FSP. CPR performance did not differ between the groups at baseline (median (IQR), BLS-ATS: 5.0 (4.4-6.1) cm, 114(96-131) cpm; BLS-EMS: 5.4 (4.1-6.4) cm, 112(99-131) cpm; ACLS-EMS: 6.4 (5.7-6.7) cm, 138(113-140) cpm; depth p=0.10, rate p=0.37). A statistically significant difference in the percentage of depth accuracy was found with feedback (median (IQR), 13.8 (0.9-49.2)% vs 69.6 (32.3-85.8)%; p=0.0002). The rate accuracy was changed from 17.1 (0-80.7)% without feedback to 59.2 (17.3-74.3)% with feedback (p=0.50). The use of feedback was effective for depth accuracy, especially in the BLS-ATS group, regardless of the

  13. Introducing systematic dispatcher-assisted cardiopulmonary resuscitation (telephone-CPR) in a non-Advanced Medical Priority Dispatch System (AMPDS): implementation process and costs.

    Science.gov (United States)

    Dami, Fabrice; Fuchs, Vincent; Praz, Laurent; Vader, John-Paul

    2010-07-01

    In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. This was a prospective study. Over an 8-week period, our EMS dispatchers were given new procedures to provide T-CPR. We then collected data on all non-traumatic cardiac arrests within our state (Vaud, Switzerland) for the following 12 months. For each event, the dispatchers had to record in writing the reason they either ruled out cardiac arrest (CA) or did not propose T-CPR in the event they did suspect CA. All emergency call recordings were reviewed by the medical director of the EMS. The analysis of the recordings and the dispatchers' written explanations were then compared. During the 12-month study period, a total of 497 patients (both adults and children) were identified as having a non-traumatic cardiac arrest. Out of this total, 203 cases were excluded and 294 cases were eligible for T-CPR. Out of these eligible cases, dispatchers proposed T-CPR on 202 occasions (or 69% of eligible cases). They also erroneously proposed T-CPR on 17 occasions when a CA was wrongly identified (false positive). This represents 7.8% of all T-CPR. No costs were incurred to implement our study protocol and procedures. This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery

  14. Organ donation in cardiac arrest patients treated with extracorporeal CPR: A single centre observational study.

    Science.gov (United States)

    Casadio, Maria Chiara; Coppo, Anna; Vargiolu, Alessia; Villa, Jacopo; Rota, Matteo; Avalli, Leonello; Citerio, Giuseppe

    2017-09-01

    In a consecutive cohort of cardiac arrest (CA) treated with extracorporeal cardiopulmonary resuscitation (eCPR), we describe the incidence of brain death (BD), the eligibility for organ donation and the short-term follow-up of the transplanted organs. All refractory in- and out-of-hospital CA admitted to our Cardiac Intensive Care Unit between January 2011 and September 2016 treated with eCPR were enrolled in the study. 112 CA patients received eCPR. 82 (73.2%) died in hospital, 25 BD (22.3%) and 57 for other causes (50.9%). At the time of first neurological evaluation after rewarming, variables related to evolution to BD were a lower GCS (3 [3-3] vs. 8 [3-11], pdonation in BD patients was 56%, with 39 donated organs: 23 kidneys, 12 livers, and 4 lungs. 89.74% of the transplanted organs reached an early good functional recovery. In refractory CA patients treated with eCPR, the prevalence of BD is high. This population has a high potential for considering organ donation. Donated organs have a good outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Depolarization Ratio Profiles Calibration and Observations of Aerosol and Cloud in the Tibetan Plateau Based on Polarization Raman Lidar

    Directory of Open Access Journals (Sweden)

    Guangyao Dai

    2018-03-01

    Full Text Available A brief description of the Water vapor, Cloud and Aerosol Lidar (WACAL system is provided. To calibrate the volume linear depolarization ratio, the concept of “ Δ 90 ° -calibration” is applied in this study. This effective and accurate calibration method is adjusted according to the design of WACAL. Error calculations and analysis of the gain ratio, calibrated volume linear depolarization ratio and particle linear depolarization ratio are provided as well. In this method, the influences of the gain ratio, the rotation angle of the plane of polarization and the polarizing beam splitter are discussed in depth. Two groups of measurements with half wave plate (HWP at angles of (0 ° , 45 ° and (22.5 ° , −22.5 ° are operated to calibrate the volume linear depolarization ratio. Then, the particle linear depolarization ratios measured by WACAL and CALIOP (the Cloud-Aerosol Lidar with Orthogonal Polarization during the simultaneous observations were compared. Good agreements are found. The calibration method was applied in the third Tibetan Plateau Experiment of Atmospheric Sciences (TIPEX III in 2013 and 2014 in China. Vertical profiles of the particle depolarization ratio of clouds and aerosol in the Tibetan Plateau were measured with WACAL in Litang (30.03° N, 100.28° E, 3949 m above sea level (a.s.l. in 2013 and Naqu (31.48° N, 92.06° E, 4508 m a.s.l. in 2014. Then an analysis on the polarizing properties of the aerosol, clouds and cirrus over the Tibetan Plateau is provided. The particle depolarization ratio of cirrus clouds varies from 0.36 to 0.52, with a mean value of 0.44 ± 0.04. Cirrus clouds occurred between 5.2 and 12 km above ground level (a.g.l.. The cloud thickness ranges from 0.12 to 2.55 km with a mean thickness of 1.22 ± 0.70 km. It is found that the particle depolarization ratio of cirrus clouds become larger as the height increases. However, the increase rate of the particle depolarization ratio becomes smaller as

  16. Edaravone improves survival and neurological outcomes after CPR in a ventricular fibrillation model of rats.

    Science.gov (United States)

    Qin, Tao; Lei, Ling-Yan; Li, Nuo; Shi, Fangying Ruan; Chen, Meng-Hua; Xie, Lu

    2016-10-01

    Overproduction of free radicals is a main factor contributing to cerebral injury after cardiac arrest (CA)/cardiopulmonary resuscitation (CPR). We sought to evaluate the impact of edaravone on the survival and neurological outcomes after CA/CPR in rats. Rats were subjected to CA following CPR. For survival study, the rats with restoration of spontaneous circulation (ROSC) were randomly allocated to one of the two groups (edaravone and saline group, n=20/each group) to received Edaravone (3 mg/kg) or normal saline. Another 10 rats without experiencing CA and CPR served as the sham group. Survival was observed for 72 hours and the neurological deficit score (NDS) was calculated at 12, 24, 48, and 72 hours after ROSC. For the neurological biochemical analysis study, rats were subjected to the same experimental procedures. Then, edaravone group (n=24), saline group (n=24) and sham group (n=16) were further divided into 4 subgroups according to the different time intervals (12, 24, 48, and 72 hours following ROSC). Brain tissues were harvested at relative time intervals for evaluation of oxidative stress, TUNEL staining and apoptotic gene expression. Edaravone improved postresuscitative survival time and neurological deficit, decreased brain malonylaldehyde level, increased superoxide dismutase activities, decreased proapoptotic gene expression of capase-8, capase-3, and Bax, and increased antiapoptotic Bcl-2 expression at 12, 24, 48, and 72 hours after ROSC. Edaravone improves survival and neurological outcomes following CPR via antioxidative and antiapoptotic effects in rats. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Bystander fatigue and CPR quality by older bystanders: a randomized crossover trial comparing continuous chest compressions and 30:2 compressions to ventilations.

    Science.gov (United States)

    Liu, Shawn; Vaillancourt, Christian; Kasaboski, Ann; Taljaard, Monica

    2016-11-01

    This study sought to measure bystander fatigue and cardiopulmonary resuscitation (CPR) quality after five minutes of CPR using the continuous chest compression (CCC) versus the 30:2 chest compression to ventilation method in older lay persons, a population most likely to perform CPR on cardiac arrest victims. This randomized crossover trial took place at three tertiary care hospitals and a seniors' center. Participants were aged ≥55 years without significant physical limitations (frailty score ≤3/7). They completed two 5-minute CPR sessions (using 30:2 and CCC) on manikins; sessions were separated by a rest period. We used concealed block randomization to determine CPR method order. Metronome feedback maintained a compression rate of 100/minute. We measured heart rate (HR), mean arterial pressure (MAP), and Borg Exertion Scale. CPR quality measures included total number of compressions and number of adequate compressions (depth ≥5 cm). Sixty-three participants were enrolled: mean age 70.8 years, female 66.7%, past CPR training 60.3%. Bystander fatigue was similar between CPR methods: mean difference in HR -0.59 (95% CI -3.51-2.33), MAP 1.64 (95% CI -0.23-3.50), and Borg 0.46 (95% CI 0.07-0.84). Compared to 30:2, participants using CCC performed more chest compressions (480.0 v. 376.3, mean difference 107.7; pCPR quality decreased significantly faster when performing CCC compared to 30:2. However, performing CCC produced more adequate compressions overall with a similar level of fatigue compared to the 30:2 method.

  18. Effect of a reminder video using a mobile phone on the retention of CPR and AED skills in lay responders.

    Science.gov (United States)

    Ahn, Ji Yun; Cho, Gyu Chong; Shon, You Dong; Park, Seung Min; Kang, Ku Hyun

    2011-12-01

    Skills related to cardiopulmonary resuscitation (CPR) and automated external defibrillator (AED) use by lay responders decay rapidly after training, and efforts are required to maintain competence among trainees. We examined whether repeated viewing of a reminder video on a mobile phone would be an effective means of maintaining CPR and AED skills in lay responders. In a single-blind case-control study, 75 male students received training in CPR and AED use. They were allocated either to the control or to the video-reminded group, who received a memory card containing a video clip about CPR and AED use for their mobile phone, which they were repeatedly encouraged to watch by SMS text message. CPR and AED skills were assessed in scenario format by examiners immediately and 3 months after initial training. Three months after initial training, the video-reminded group showed more accurate airway opening (PCPR after defibrillation (PCPR confidence scores and increased willingness to perform bystander CPR in cardiac arrest than the controls at 3 months (PCPR and AED skills in lay responders. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Nurses' behaviour regarding CPR and the theories of reasoned action and planned behaviour.

    Science.gov (United States)

    Dwyer, Trudy; Mosel Williams, Leonie

    2002-01-01

    Cardiopulmonary resuscitation (CPR) has been used in hospitals for approximately 40 years. Nurses are generally the first responders to a cardiac arrest and initiate basic life support while waiting for the advanced cardiac life support team to arrive. Speed and competence of the first responder are factors contributing to the initial survival of a person following a cardiac arrest. Attitudes of individual nurses may influence the speed and level of involvement in true emergency situations. This paper uses the theories of reasoned action and planned behaviour to examine some behavioural issues with CPR involvement.

  20. Computer-Based CPR Simulation Towards Validation of AHA/ERC Guidelines.

    Science.gov (United States)

    John, Alka Rachel; Manivannan, M; Ramakrishnan, T V

    2017-06-01

    As per the AHA 2015 and ERC 2015 guidelines for resuscitation, chest compression depth should be between 5 and 6 cm with a rate of 100-120 compressions per minute. Theoretical validation of these guidelines is still elusive. We developed a computer model of the cardiopulmonary resuscitation (CPR) system to validate these guidelines. A lumped element computer model of the cardiovascular system was developed to simulate cardiac arrest and CPR. Cardiac output was compared for a range of compression pressures and frequencies. It was observed from our investigation that there is an optimum compression pressure and rate. The maximum cardiac output occurred at 100 mmHg, which is approximately 5.7 cm, and in the range of 100 to 120 compressions per minute with an optimum value at 110 compressions per minute, validating the guidelines. Increasing the pressure or the depth of compression beyond the optimum, limits the blood flow by depleting the volume in the cardiac chambers and not allowing for an effective stroke volume. Similarly increasing the compression rate beyond the optimum degrades the ability of the chambers to pump blood. The results also bring out the importance of complete recoil of the chest after each compression with more than 400% increase in cardiac output from 90% recoil to 100% recoil. Our simulation predicts that the recommendation to compress harder and faster is not the best counsel as there is an optimum compression pressure and rate for high-quality CPR.

  1. Considering the CPR Decision Through the Lens of Prospect Theory in the Context of Advanced Chronic Illness.

    Science.gov (United States)

    Bern-Klug, Mercedes

    2017-02-01

    It is common for people with advanced chronic illness to have many health care providers and many health care-related visits. It is also common, during those visits, to be asked whether attempts at cardiopulmonary resuscitation (CPR) are desired, in the event of cardiac arrest. Although the question is common, the implications of a "yes" or a "no" may not be well understood. Although CPR can be a life-saving procedure, it is not always in the patient's best interest. This article discusses experiences with CPR of 2 older women (and their adult children) during their last years of life, and uses concepts from prospect theory to make suggestions for changes in the way health care providers and patients approach advance care planning including the CPR decision. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. The effectiveness of CPR training during anesthesia internship rotation on improvement of interns, knowledge and clinical skills of Lorestan university of medical sciences

    Directory of Open Access Journals (Sweden)

    sepideh Vahabi

    2015-09-01

    Full Text Available Background : Since only the correct and effective Cardiopulmonary Resuscitation (CPR can increase the survival of patients with cardiopulmonary arrest, the aim of this study is to determine the effects of CPR training in the anesthetioligy ward to improve CPR knowledge and clinical skills of interns of Lorestan university of medical sciences. Materials and Methods : A 10-month Educational experimental study was done on 31 undergraduate medical students at Lorestan university of medical sciences in 2013. During a period of 15 days of anesthesiology internship course, all these students underwent CPR training including Basic Life Support ( BLS , Advanced Cardiac Life Support ( ACLS and practical skills. Data were collected via a questionnaire with 4 parts including demographic, pre and post knowledge and skills as standpoint of interns and ward,s professor. Results: After training the mean of score about knowledge of CPR and its practical skills significantly increased from 5.68 to 7.94 and 10.65 to 23.45 respectivly (PV=0.0001 . A significant relationship between preinternship exam score and knowledge of CPR before anesthesiology internship course was shown (PV=0.001, but there was no significant relationship with practical skills score pre and post CPR training in anesthesilogy ward.(PV=0.38 Conclusion: The CPR training course in anesthetiology ward leads to significant increase in CPR skills and Knowledge of medical interns. Adding this course to undergraduated medical students is essential

  3. Influence of Zr/Ti ratio and preferred orientation on polarization switching and domain configuration of Pb(Zr1-xTix)O3 thin films

    International Nuclear Information System (INIS)

    Lee, Young Hyun; Lee, Jung Kun; Hong, Kug Sun

    2003-01-01

    The (100) and (111) oriented Pb(Zr 1-x Ti x )O 3 (PZT) thins films were prepared on Pt/TiO 2 /SiO 2 /Si(100) substrate using sol-gel process. The ferroelectric and dielectric properties were evaluated as a function of Zr/Ti ratio and the origin of their changes were discussed in terms of domain engineering. With increasing Zr/Ti ratio, the remnant polarization of the polar axis decreased from 23.87 to 10.66 μC/cm 2 and the difference of the saturated polarization between polar axis and non-polar axis increased systematically. The fatigue rate of PZT films was disproportional to Zr/Ti ratio. At a composition of x = 0.7, the remnant polarization decreased from 2P r = 30.82 μC/cm 2 to 26.60 μC/cm 2 after 6.9 x 10 10 cycles. The fatigue rate was also related to the direction of polarization reversal and the increased fatigue behavior was observed in polar axis. These results were discussed with the aid of the domain configuration and the switching current, which revealed the role of the internal stress on ferroelectric property of PZT films

  4. The combined use of mechanical CPR and a carry sheet to maintain quality resuscitation in out-of-hospital cardiac arrest patients during extrication and transport.

    Science.gov (United States)

    Lyon, Richard M; Crawford, Anna; Crookston, Colin; Short, Steven; Clegg, Gareth R

    2015-08-01

    Quality of manual cardiopulmonary resuscitation (CPR) during extrication and transport of out-of-hospital cardiac arrest victims is known to be poor. Performing manual CPR during ambulance transport poses significant risk to the attending emergency medical services crew. We sought to use pre-hospital video recording to objectively analyse the impact of introducing mechanical CPR with an extrication sheet (Autopulse, Zoll) to an advanced, second-tier cardiac arrest response team. The study was conducted prospectively using defibrillator downloads and analysis of pre-hospital video recording to measure the quality of CPR during extrication from scene and ambulance transport of the OHCA patient. Adult patients with non-traumatic OHCA were included. The interruption to manual CPR to during extrication and to deploy the mechanical CPR device was analysed. In the manual CPR group, 53 OHCA cases were analysed for quality of CPR during extrication. The median time that chest compression was interrupted to allow the patient to be carried from scene to the ambulance was 270 s (IQR 201-387 s). 119 mechanical CPR cases were analysed. The median time interruption from last manual compression to first Autopulse compression was 39 s (IQR 29-47 s). The range from last manual compression to first Autopulse compression was 14-118 s. Mechanical CPR used in combination with an extrication sheet can be effectively used to improve the quality of resuscitation during extrication and ambulance transport of the refractory OHCA patient. The time interval to deploy the mechanical CPR device can be shortened with regular simulation training. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Crystal structure of conjugated polyketone reductase (CPR-C1) from Candida parapsilosis IFO 0708 complexed with NADPH.

    Science.gov (United States)

    Qin, Hui-Min; Yamamura, Akihiro; Miyakawa, Takuya; Kataoka, Michihiko; Maruoka, Shintaro; Ohtsuka, Jun; Nagata, Koji; Shimizu, Sakayu; Tanokura, Masaru

    2013-11-01

    Conjugated polyketone reductase (CPR-C1) from Candida parapsilosis IFO 0708 is a member of the aldo-keto reductase (AKR) superfamily and reduces ketopantoyl lactone to d-pantoyl lactone in a NADPH-dependent and stereospecific manner. We determined the crystal structure of CPR-C1.NADPH complex at 2.20 Å resolution. CPR-C1 adopted a triose-phosphate isomerase (TIM) barrel fold at the core of the structure in which Thr25 and Lys26 of the GXGTX motif bind uniquely to the adenosine 2'-phosphate group of NADPH. This finding provides a novel structural basis for NADPH binding of the AKR superfamily. Copyright © 2013 Wiley Periodicals, Inc.

  6. Spectral, stoichiometric ratio, physicochemical, polarity and photostability studies of newly synthesized chalcone dye in organized media

    International Nuclear Information System (INIS)

    Marwani, Hadi M.; Asiri, Abdullah M.; Khan, Salman A.

    2013-01-01

    The main focus of this study was to investigate spectroscopic properties, stoichiometric ratios, physicochemical parameters, polarity and photostability behaviors of newly synthesized chalcone dye in organized media. The chalcone dye, 1-(2,5-Dimethyl-thiophen-3-yl)-3-(9-etnyl-9H-carbazol-3-yl)-propenone (DTEP), was prepared by the reaction of carbazole aldehyde with 3-acetyl-2,5-dimethythiophene. Data obtained from FT-IR, 1 H-–NMR, 13 C-NMR and elemental analysis were consistent with chemical structure of newly prepared DTEP. Increases in fluorescence intensities of DTEP with cetyltrimethyl ammonium bromide (CTAB) were observed. In comparison of fluorescence intensities for DTEP with CTAB, reductions in fluorescence intensities for DTEP with sodium dodecyl sulfate (SDS) were noticed under the same experimental and instrumental conditions. Additionally, Benesi–Hildebrand method was applied to determine stoichiometric ratios and association constants of DTEP with CTAB and SDS. Stern–Volmer plot was used in order to further confirm the stoichiometric ratio and association constant of DTEP with SDS. Physicochemical parameters such as singlet absorption, molar absorptivity, oscillator strength, dipole moment and fluorescence quantum yield of DTEP were also determined. Fluorescence polarity study displayed that DTEP was sensitive to the polarity of the microenvironment provided by different solvents. Finally, fluorescence steady-state measurements revealed that DTEP has high photostability against photobleaching. -- Highlights: ► Mechanistic understanding of molecular structure of newly synthesized chalcone dye. ► Exploring spectral behaviors and physicochemical parameters of chalcone dye. ► Determination of stoichiometric ratios and association constants of chalcone dye. ► Determination of fluorescence quantum yield in different solvents. ► High photostability against photobleaching of chalcone dye was observed

  7. Development of a smart backboard system for real-time feedback during CPR chest compression on a soft back support surface.

    Science.gov (United States)

    Gohier, Francis; Dellimore, Kiran; Scheffer, Cornie

    2013-01-01

    The quality of cardiopulmonary resuscitation (CPR) is often inconsistent and frequently fails to meet recommended guidelines. One promising approach to address this problem is for clinicians to use an active feedback device during CPR. However, one major deficiency of existing feedback systems is that they fail to account for the displacement of the back support surface during chest compression (CC), which can be important when CPR is performed on a soft surface. In this study we present the development of a real-time CPR feedback system based on an algorithm which uses force and dual-accelerometer measurements to provide accurate estimation of the CC depth on a soft surface, without assuming full chest decompression. Based on adult CPR manikin tests it was found that the accuracy of the estimated CC depth for a dual accelerometer feedback system is significantly better (7.3% vs. 24.4%) than for a single accelerometer system on soft back support surfaces, in the absence or presence of a backboard. In conclusion, the algorithm used was found to be suitable for a real-time, dual accelerometer CPR feedback application since it yielded reasonable accuracy in terms of CC depth estimation, even when used on a soft back support surface.

  8. Cerebroplacental ratio thresholds measured within two weeks of birth and the risk of Cesarean section for intrapartum fetal compromise and adverse neonatal outcome.

    Science.gov (United States)

    N Bligh, Larissa; Alsolai, Amal A; Greer, Ristan M; Kumar, Sailesh

    2017-06-08

    Prediction of intrapartum fetal compromise in uncomplicated, term pregnancies is a global obstetric challenge. Currently, no widely accepted screening test for this condition exists, although the cerebroplacental ratio (CPR) shows promise. We aimed to prospectively evaluate the screening performance of the CPR 10 th centile for detection of Cesarean section for intrapartum fetal compromise (IFC) and composite adverse neonatal outcome (ANO) in low-risk women from 36 weeks and to determine the best CPR threshold from three previously described in the literature. In a blinded, prospective, observational, cohort study, 483 women with uncomplicated singleton pregnancies underwent fortnightly CPR measurement from 36 weeks to delivery and intrapartum and neonatal outcomes were recorded. The CPR 10 th centile threshold screening test performance was calculated for emergency Cesarean section for IFC and composite ANO, incorporating acidosis at birth, Apgar Cesarean section for IFC and 17.9% had a composite ANO. Sensitivity and specificity for CPR Cesarean section IFC and composite ANO, respectively. Comparing the three CPR thresholds, CPR Cesarean section for IFC area under the receiver operating characteristic curve = 0.72, composite ANO area under the receiver operating characteristic curve = 0.58), although its predictive utility was only fair for Cesarean section for IFC and poor for composite ANO. The CPR 10 th centile may be useful as a component of a risk assessment tool for Cesarean section for IFC in low risk pregnancies at term. This article is protected by copyright. All rights reserved.

  9. The fetal cerebro-placental ratio in diabetic pregnancies is influenced more by the umbilical artery rather than middle cerebral artery pulsatility index.

    Science.gov (United States)

    Gibbons, Anthea; Flatley, Christopher; Kumar, Sailesh

    2017-04-01

    This study aimed to assess the relationship between the cerebro-placental ratio (CPR) and intrapartum and perinatal outcomes in pregnancies complicated by pre-existing insulin dependent diabetes (pT1DM) mellitus, pre-existing non-insulin dependent diabetes mellitus (pT2DM) and gestational diabetes mellitus (GDM). This was a retrospective cohort study of 1281 women with diabetes mellitus birthing at the Mater Mothers' Hospital in Brisbane between 2007 and 2015. The CPR in non-anomalous singleton fetuses was measured between 34+0 and 36+6 weeks gestation and compared between types of DM treatment groups and correlated with intrapartum and perinatal outcomes. Of the study cohort, 9.7% (124/1281) had pT1DM, 5.3% (68/1281) had pT2DM and 85.0% (1089/1281) had GDM. Of women with pT2DM and GDM, 61.8% (42/68) and 28.9% (315/1089) respectively, required insulin during pregnancy. Women with pT1DM had an increased odds of having a CPR 90th centile (OR 2.69, 95% CI: 1.60-4.39, p=0.0001) was higher in the pT1DM cohort. There was however no significant difference in the mean MCA PI between the three groups. Stratification by CPR centiles (<10th centile vs. ≥10th centile) demonstrated a lower birth weight in the CPR <10th centile cohort for all DM categories. The proportion of neonates with birth weights <10th centile were higher in the CPR <10th centile cohort with the GDM cohort having an odds ratio of 8.28 (95% CI 4.22-16.13, p<0.0001) of this complication. The CPR <10th centile cohort also had a greater proportion of adverse composite neonatal outcome regardless of type of DM. Regardless of the type of DM, a low CPR was associated with poorer neonatal outcomes. Women with pT1DM also had the highest mean UA PI and lowest mean CPR despite no difference in the mean MCA PI between the three groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Design of the RINSE Trial: The Rapid Infusion of cold Normal Saline by paramedics during CPR

    Directory of Open Access Journals (Sweden)

    Jacobs Ian

    2011-10-01

    Full Text Available Abstract Background The International Liaison Committee on Resuscitation (ILCOR now recommends therapeutic hypothermia (TH (33°C for 12-24 hours as soon as possible for patients who remain comatose after resuscitation from shockable rhythm in out-of-hospital cardiac arrest and that it be considered for non shockable rhythms. The optimal timing of TH is still uncertain. Laboratory data have suggested that there is significantly decreased neurological injury if cooling is initiated during CPR. In addition, peri-arrest cooling may increase the rate of successful defibrillation. This study aims to determine whether paramedic cooling during CPR improves outcome compared standard treatment in patients who are being resuscitated from out-of-hospital cardiac arrest. Methods/Design This paper describes the methodology for a definitive multi-centre, randomised, controlled trial of paramedic cooling during CPR compared with standard treatment. Paramedic cooling during CPR will be achieved using a rapid infusion of large volume (20-40 mL/kg to a maximum of 2 litres ice-cold (4°C normal saline. The primary outcome measure is survival at hospital discharge. Secondary outcome measures are rates of return of spontaneous circulation, rate of survival to hospital admission, temperature on arrival at hospital, and 12 month quality of life of survivors. Discussion This trial will test the effect of the administration of ice cold saline during CPR on survival outcomes. If this simple treatment is found to improve outcomes, it will have generalisability to prehospital services globally. Trial Registration ClinicalTrials.gov: NCT01172678

  11. CPR in medical schools: learning by teaching BLS to sudden cardiac death survivors – a promising strategy for medical students?

    Directory of Open Access Journals (Sweden)

    Herkner Harald

    2006-04-01

    Full Text Available Abstract Background Cardiopulmonary resuscitation (CPR training is gaining more importance for medical students. There were many attempts to improve the basic life support (BLS skills in medical students, some being rather successful, some less. We developed a new problem based learning curriculum, where students had to teach CPR to cardiac arrest survivors in order to improve the knowledge about life support skills of trainers and trainees. Methods Medical students who enrolled in our curriculum had to pass a 2 semester problem based learning session about the principles of cardiac arrest, CPR, BLS and defibrillation (CPR-D. Then the students taught cardiac arrest survivors who were randomly chosen out of a cardiac arrest database of our emergency department. Both, the student and the Sudden Cardiac Death (SCD survivor were asked about their skills and knowledge via questionnaires immediately after the course. The questionnaires were then used to evaluate if this new teaching strategy is useful for learning CPR via a problem-based-learning course. The survey was grouped into three categories, namely "Use of AED", "CPR-D" and "Training". In addition, there was space for free answers where the participants could state their opinion in their own words, which provided some useful hints for upcoming programs. Results This new learning-by-teaching strategy was highly accepted by all participants, the students and the SCD survivors. Most SCD survivors would use their skills in case one of their relatives goes into cardiac arrest (96%. Furthermore, 86% of the trainees were able to deal with failures and/or disturbances by themselves. On the trainer's side, 96% of the students felt to be well prepared for the course and were considered to be competent by 96% of their trainees. Conclusion We could prove that learning by teaching CPR is possible and is highly accepted by the students. By offering a compelling appreciation of what CPR can achieve in using

  12. An appropriate compression pace is important for securing the quality of hands-only CPR--a manikin study.

    Science.gov (United States)

    Shimizu, Yoshitaka; Tanigawa, Koichi; Ishikawa, Masami; Ouhara, Kazuhisa; Oue, Kana; Yoshinaka, Taiga; Kurihara, Hidemi; Irifune, Masahiro

    2014-09-01

    It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-second break between the sets. The percentage of compressions deeper than 5 cm at pace-110-g decreased significantly from 22.1 ± 4.7% in the first set to 16.7 ± 4.4%* in the second set (*p CPR.

  13. Analysis of small break loss of coolant accident for Chinese CPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Youl [FNC Technology Co., Yongin (Korea, Republic of); Cilier, Anthonie [North-West University, Mahikeng (South Africa); Poc, Li-chi Cliff [Micro-Simulation Technology, Montville (United States)

    2016-05-15

    This research analyses the small break loss of coolant accident (LOCA) on a Chinese CPR1000 type reactor. LOCA accident is used as benchmark for the PCTRAN/CPR1000 code by comparing the effects and results to the Manshaan FSAR accident analysis. LOCA is a design basis accident in which a guillotine break is postulated to occur in one of the cold legs of a pressurized water reactor (PWR). Consequently, the primary system pressure would drop and almost all the reactor coolant would be discharged into the reactor containment. The drop in pressure would activate the reactor protection system and the reactor would trip. The simulation of a 3-inch small break loss of coolant accident using the PCTRAN/CPR1000 has revealed this code's effectiveness as well as weaknesses in specific simulation applications. The code has the ability to run at 16 times real time and produce very accurate results. The results are consistently producing the same trends as licensed codes used in Safety Assessment Reports. It is however able to produce these results in a fraction of the time and also provides a whole plant simulation coupling the various thermal, hydraulic, chemical and neutronic systems together with a plant specific control system.

  14. Progress Towards a Global Understanding of Plankton Dynamics: The Global Alliance of CPR Surveys (GACS)

    Science.gov (United States)

    Batten, S.; Richardson, A.; Melrose, C.; Muxagata, E.; Hosie, G.; Verheye, H.; Hall, J.; Edwards, M.; Koubbi, P.; Abu-Alhaija, R.; Chiba, S.; Wilson, W.; Nagappa, R.; Takahashi, K.

    2016-02-01

    The Continuous Plankton Recorder (CPR) was first used in 1931 to routinely sample plankton and its continued deployment now sustains the longest-running, and spatially most extensive marine biological sampling programme in the world. Towed behind, for the most part commercial, ships it collects plankton samples from the surface waters that are subsequently analysed to provide taxonomically-resolved abundance data on a broad range of planktonic organisms from the size of coccolithophores to euphausiids. Plankton appear to integrate changes in the physical environment and by underpinning most marine food-webs, pass on this variability to higher trophic levels which have societal value. CPRs are deployed increasingly around the globe in discrete regional surveys that until recently interacted in an informal way. In 2011 the Global Alliance of CPR Surveys (GACS) was launched to bring these surveys together to collaborate more productively and address issues such as: methodological standardization, data integration, capacity building, and data analysis. Early products include a combined global database and regularly-released global marine ecological status reports. There are, of course, limitations to the exploitation of CPR data as well as the current geographic coverage. A current focus of GACS is integration of the data with models to meaningfully extrapolate across time and space. In this way the output could be used to provide more robust synoptic representations of key plankton variables. Recent years have also seen the CPR used as a platform in itself with the inclusion of additional sensors and water samplers that can sample the microplankton. The archive of samples has already been used for some molecular investigations and curation of samples is maintained for future studies. Thus the CPR is a key element of any regional to global ocean observing system of biodiversity.

  15. Presentation of the CPR ISMIR (Insulators: IRradiation Modelling); Presentation du CPR ISMIR (ISolants: modelisation de l'IRradiation)

    Energy Technology Data Exchange (ETDEWEB)

    Lozes, G. [CEA Saclay, Dir. de l' Energie Nucleaire (DEN/DSOE), 91 - Gif sur Yvette (France)

    2007-07-01

    The CPR ISMIR is a CEA-CNRS program on the behaviour of materials submitted to irradiation; it has been begun to support the applied current research programs on the aging of nuclear fuels, the storage and incineration matrices and the future reactors. Its aim is to contribute to scientifically set up the methods for anticipating the behaviour of ceramic materials under irradiation in using the important development of calculation means. Thus have been developed the basic knowledge and the interactions physics and calculation models at pertinent scales have been elaborated. (O.M.)

  16. Broadband photonic crystal fiber coupler with polarization selection of coupling ratio

    Science.gov (United States)

    Jaroszewicz, Leszek R.; Stasiewicz, Karol A.; Marć, Paweł; Szymański, Michał

    2010-09-01

    In the paper a new broadband photonic crystal fiber coupler is presented. The proper application of the biconical taper technology has been used for manufacturing the coupler without air holes collapse in LMA10 fiber (NKT Photonics Crystal). This coupler, operates in the weakly coupling condition, protects coupling operation in range from 900 nm to 1700 nm. The coupling ratio between output arms is depending on wavelength and can be tuning by selection the proper input state of polarization. It gives opportunity to use the broadband crystal fiber coupler in many applications in which it is necessary to tune a coupling between output arms during the measurement.

  17. Does real-time objective feedback and competition improve performance and quality in manikin CPR training--a prospective observational study from several European EMS.

    Science.gov (United States)

    Smart, J R; Kranz, K; Carmona, F; Lindner, T W; Newton, A

    2015-10-15

    Previous studies have reported that the quality of cardiopulmonary resuscitation (CPR) is important for patient survival. Real time objective feedback during manikin training has been shown to improve CPR performance. Objective measurement could facilitate competition and help motivate participants to improve their CPR performance. The aims of this study were to investigate whether real time objective feedback on manikins helps improve CPR performance and whether competition between separate European Emergency Medical Services (EMS) and between participants at each EMS helps motivation to train. Ten European EMS took part in the study and was carried out in two stages. At Stage 1, each EMS provided 20 pre-hospital professionals. A questionnaire was completed and standardised assessment scenarios were performed for adult and infant out of hospital cardiac arrest (OHCA). CPR performance was objectively measured and recorded but no feedback given. Between Stage 1 and 2, each EMS was given access to manikins for 6 months and instructed on how to use with objective real-time CPR feedback available. Stage 2 was undertaken and was a repeat of Stage 1 with a questionnaire with additional questions relating to usefulness of feedback and the competition nature of the study (using a 10 point Likert score). The EMS that improved the most from Stage 1 to Stage 2 was declared the winner. An independent samples Student t-test was used to analyse the objective CPR metrics with the significance level taken as p Competition between EMS organisations recorded a mean score of 5.8 and competition between participants recorded a mean score of 6.0. The results suggest that the use of real time objective feedback can significantly help improve CPR performance. Competition, especially between participants, appeared to encourage staff to practice and this study suggests that competition might have a useful role to help motivate staff to perform CPR training.

  18. A study assessing the impact of different teaching modalities for pharmacy students in a Cardio-Pulmonary Resuscitation (CPR) course.

    Science.gov (United States)

    Khan, Tahir Mehmood; Hassali, Mohamed Azmi; Rasool, Sahibzada Tasleem

    2013-10-01

    The current study aims to assess the effectiveness of different teaching methods adopted for the practical session of Cardio-Pulmonary Resuscitation (CPR). CPR training is one of the compulsory modules of the Public Health Pharmacy (PHP) course at Universiti Sains Malaysia. CPR training comprises of 10% of total marks of the PHP course. To test the effectiveness of the different teaching strategies, three groups were defined using a two-stage cohort distribution-i.e. based on grade point average (GPA) and different teaching modalities. Group One was instructed using images and PowerPoint lecture slides. Group Two was instructed using videos and PowerPoint lecture slides. Group Three was instructed using PowerPoint slides with white boards and videos. Students in Group Three were not provided with a hard/soft copy of the PowerPoint slides and were encouraged to write down all the information on their personal notebooks. A 20-item questionnaire was used to assess the students' understanding toward the CPR session. Data were analyzed using the Statistical Package for Social Science Students, SPSS version 13®. Based on the response attained, the comparison of the final score among the groups was undertaken using one way ANOVA. Twenty-seven students have participated in this study. Final evaluation using the questionnaire revealed that student's in Group Three had a better understanding of CPR (18.1 ± 1.5, p lecture and use of traditional chalkboard teaching were found significant to improve the students' understanding and learning in the CPR session.

  19. Branching ratios, CP asymmetries and polarizations of B → ψ(2S)V decays

    Energy Technology Data Exchange (ETDEWEB)

    Rui, Zhou [North China University of Science and Technology, College of Sciences, Tangshan (China); Li, Ya; Xiao, Zhen-Jun [Nanjing Normal University, Department of Physics and Institute of Theoretical Physics, Nanjing, Jiangsu (China)

    2017-09-15

    We analyze the non-leptonic decays B/B{sub s} → ψ(2S)V with V = (ρ, ω, K*, φ) by employing the perturbative QCD (pQCD) factorization approach. Here the branching ratios, the CP asymmetries and the complete set of polarization observables are investigated systematically. Besides the traditional contributions from the factorizable and non-factorizable diagrams at the leading order, the next-to-leading order (NLO) vertex corrections could also provide considerable contributions. The pQCD predictions for the branching ratios of the B{sub (s)} → ψ(2S)K*, ψ(2S)φ decays are consistent with the measured values within errors. As for B → ψ(2S)ρ, ψ(2S)ω decays, the branching ratios can reach the order of 10{sup -5} and could be measured in the LHCb and Belle-II experiments. The numerical results show that the direct CP asymmetries of the considered decays are very small. Thus the observation of any large direct CP asymmetry for these decays will be a signal for new physics. The mixing-induced CP asymmetries in the neutral modes are very close to sin 2β{sub (s)}, which suggests that these channels can give a cross-check on the measurement of the Cabbibo-Kobayashi-Maskawa (CKM) angle β and β{sub s}. We find that the longitudinal polarization fractions f{sub 0} are suppressed to ∝ 50% due to the large non-factorizable contributions. The magnitudes and phases of the two transverse amplitudes A {sub parallel} and A {sub perpendicular} {sub to} are roughly equal, which is an indication for the approximate light-quark helicity conservation in these decays. The overall polarization observables of B → ψ(2S)K{sup *0} and B{sub s} → ψ(2S)φ channels are also in good agreement with the experimental measurements as reported by LHCb and BaBar. Other results can also be tested by the LHCb and Belle-II experiments. (orig.)

  20. Optimal Chest Compression Rate and Compression to Ventilation Ratio in Delivery Room Resuscitation: Evidence from Newborn Piglets and Neonatal Manikins

    Science.gov (United States)

    Solevåg, Anne Lee; Schmölzer, Georg M.

    2017-01-01

    Cardiopulmonary resuscitation (CPR) duration until return of spontaneous circulation (ROSC) influences survival and neurologic outcomes after delivery room (DR) CPR. High quality chest compressions (CC) improve cerebral and myocardial perfusion. Improved myocardial perfusion increases the likelihood of a faster ROSC. Thus, optimizing CC quality may improve outcomes both by preserving cerebral blood flow during CPR and by reducing the recovery time. CC quality is determined by rate, CC to ventilation (C:V) ratio, and applied force, which are influenced by the CC provider. Thus, provider performance should be taken into account. Neonatal resuscitation guidelines recommend a 3:1 C:V ratio. CCs should be delivered at a rate of 90/min synchronized with ventilations at a rate of 30/min to achieve a total of 120 events/min. Despite a lack of scientific evidence supporting this, the investigation of alternative CC interventions in human neonates is ethically challenging. Also, the infrequent occurrence of extensive CPR measures in the DR make randomized controlled trials difficult to perform. Thus, many biomechanical aspects of CC have been investigated in animal and manikin models. Despite mathematical and physiological rationales that higher rates and uninterrupted CC improve CPR hemodynamics, studies indicate that provider fatigue is more pronounced when CC are performed continuously compared to when a pause is inserted after every third CC as currently recommended. A higher rate (e.g., 120/min) is also more fatiguing, which affects CC quality. In post-transitional piglets with asphyxia-induced cardiac arrest, there was no benefit of performing continuous CC at a rate of 90/min. Not only rate but duty cycle, i.e., the duration of CC/total cycle time, is a known determinant of CC effectiveness. However, duty cycle cannot be controlled with manual CC. Mechanical/automated CC in neonatal CPR has not been explored, and feedback systems are under-investigated in this

  1. An evaluation of designed passive Core Makeup Tank (CMT) for China pressurized reactor (CPR1000)

    International Nuclear Information System (INIS)

    Wang, Mingjun; Tian, Wenxi; Qiu, Suizheng; Su, Guanghui; Zhang, Yapei

    2013-01-01

    Highlights: ► Only PRHRS is not sufficient to maintain reactor safety in case of SGTR accident. ► The Core Makeup Tank (CMT) is designed for CPR1000. ► Joint operation of PRHRS and CMT can keep reactor safety during the SGTR transient. ► CMT is a vital supplement for CPR1000 passive safety system design. - Abstract: Emergency Passive Safety System (EPSS) is an innovative design to improve reliability of nuclear power plants. In this work, the EPSS consists of secondary passive residual heat removal system (PRHRS) and the reactor Core Makeup Tank (CMT) system. The PRHRS, which has been studied in our previous paper, can effectively remove the core residual heat and passively improve the inherent safety by passive methods. The designed CMT, representing the safety improvement for CPR1000, is used to inject cool boron-containing water into the primary system during the loss of coolant accident. In this study, the behaviors of EPSS and transient characteristics of the primary loop system during the Steam Generator Tube Rupture (SGTR) accident are investigated using the nuclear reactor thermal hydraulic code RELAP5/MOD3.4. The results show that the designed CMT can protect the reactor primary loop from boiling and maintain primary loop coolant in single phase state. Both PRHRS and CMT operation ensures reactor safety during the SGTR accident. Results reported in this paper show that the designed CMT is a further safety improvement for CPR1000

  2. CPR in the Schools: Training Students to Save Heart Attack Victims.

    Science.gov (United States)

    Britton, Royce J.

    1978-01-01

    A community cardiac emergency medical plan should include training of family and co-workers of high risk patients, including teenage students. The American Heart Association lists ways to introduce cardiopulmonary resuscitation (CPR) into school curricula and describes the plan implemented in Pennsylvania. (MF)

  3. The silkworm Bombyx mori cuticular protein CPR55 gene is regulated by the transcription factor βFTZ-F1

    Directory of Open Access Journals (Sweden)

    Md. Saheb Ali

    2016-01-01

    Full Text Available The insect cuticle is composed of various proteins and formed during the moult under a complex biological process that depends on the cross talk between hormone levels and gene expression. In the present study, we aimed to clarify the ecdysone-dependent temporal regulation mechanisms of cuticular proteins expression and the underlying control of Bombyx mori metamorphosis. The expression of CPR55 was observed from the W3 early stage and peaked at pupation when the ecdysteroid titre declined. CPR55 was induced by the ecdysone pulse, and their expression peaked at 24 h after transfer to a hormone free medium. Transcripts of CPR55 were neither observed after the 20E pulse treatment in the presence of cycloheximide nor after the addition of 20E in V4 wing discs. We analysed the upstream region of the CPR55 gene using a transient reporter assay with a gene gun system which identified only one βFTZ-F1 binding site important for cis-acting elements for the transcription activation of the luciferase reporter gene by an ecdysone pulse. Site-directed mutagenesis of this element in the context of the 589-bp promoter fragment drastically decreased the reporter activity. The nuclear protein bound to βFTZ-F1 sites was identified by an electrophoretic mobility shift assay suggesting that CPR55 expression was regulated by βFTZ-F1 through the ecdysone pulse. The results confirmed that transcription factor, BmβFTZ-F1, binds to the cis-regulatory elements in the promoter of the gene coding for cuticle protein, CPR55, and regulates its expression during B. mori metamorphosis.

  4. Arecibo Radar Observation of Near-Earth Asteroids: Expanded Sample Size, Determination of Radar Albedos, and Measurements of Polarization Ratios

    Science.gov (United States)

    Lejoly, Cassandra; Howell, Ellen S.; Taylor, Patrick A.; Springmann, Alessondra; Virkki, Anne; Nolan, Michael C.; Rivera-Valentin, Edgard G.; Benner, Lance A. M.; Brozovic, Marina; Giorgini, Jon D.

    2017-10-01

    The Near-Earth Asteroid (NEA) population ranges in size from a few meters to more than 10 kilometers. NEAs have a wide variety of taxonomic classes, surface features, and shapes, including spheroids, binary objects, contact binaries, elongated, as well as irregular bodies. Using the Arecibo Observatory planetary radar system, we have measured apparent rotation rate, radar reflectivity, apparent diameter, and radar albedos for over 350 NEAs. The radar albedo is defined as the radar cross-section divided by the geometric cross-section. If a shape model is available, the actual cross-section is known at the time of the observation. Otherwise we derive a geometric cross-section from a measured diameter. When radar imaging is available, the diameter was measured from the apparent range depth. However, when radar imaging was not available, we used the continuous wave (CW) bandwidth radar measurements in conjunction with the period of the object. The CW bandwidth provides apparent rotation rate, which, given an independent rotation measurement, such as from lightcurves, constrains the size of the object. We assumed an equatorial view unless we knew the pole orientation, which gives a lower limit on the diameter. The CW also provides the polarization ratio, which is the ratio of the SC and OC cross-sections.We confirm the trend found by Benner et al. (2008) that taxonomic types E and V have very high polarization ratios. We have obtained a larger sample and can analyze additional trends with spin, size, rotation rate, taxonomic class, polarization ratio, and radar albedo to interpret the origin of the NEAs and their dynamical processes. The distribution of radar albedo and polarization ratio at the smallest diameters (≤50 m) differs from the distribution of larger objects (>50 m), although the sample size is limited. Additionally, we find more moderate radar albedos for the smallest NEAs when compared to those with diameters 50-150 m. We will present additional trends we

  5. Image sensor pixel with on-chip high extinction ratio polarizer based on 65-nm standard CMOS technology.

    Science.gov (United States)

    Sasagawa, Kiyotaka; Shishido, Sanshiro; Ando, Keisuke; Matsuoka, Hitoshi; Noda, Toshihiko; Tokuda, Takashi; Kakiuchi, Kiyomi; Ohta, Jun

    2013-05-06

    In this study, we demonstrate a polarization sensitive pixel for a complementary metal-oxide-semiconductor (CMOS) image sensor based on 65-nm standard CMOS technology. Using such a deep-submicron CMOS technology, it is possible to design fine metal patterns smaller than the wavelengths of visible light by using a metal wire layer. We designed and fabricated a metal wire grid polarizer on a 20 × 20 μm(2) pixel for image sensor. An extinction ratio of 19.7 dB was observed at a wavelength 750 nm.

  6. A survey of attitudes and factors associated with successful cardiopulmonary resuscitation (CPR knowledge transfer in an older population most likely to witness cardiac arrest: design and methodology

    Directory of Open Access Journals (Sweden)

    Brehaut Jamie C

    2008-11-01

    Full Text Available Abstract Background Overall survival rates for out-of-hospital cardiac arrest rarely exceed 5%. While bystander cardiopulmonary resuscitation (CPR can increase survival for cardiac arrest victims by up to four times, bystander CPR rates remain low in Canada (15%. Most cardiac arrest victims are men in their sixties, they usually collapse in their own home (85% and the event is witnessed 50% of the time. These statistics would appear to support a strategy of targeted CPR training for an older population that is most likely to witness a cardiac arrest event. However, interest in CPR training appears to decrease with advancing age. Behaviour surrounding CPR training and performance has never been studied using well validated behavioural theories. Methods/Design The overall goal of this study is to conduct a survey to better understand the behavioural factors influencing CPR training and performance in men and women 55 years of age and older. The study will proceed in three phases. In phase one, semi-structured qualitative interviews will be conducted and recorded to identify common categories and themes regarding seeking CPR training and providing CPR to a cardiac arrest victim. The themes identified in the first phase will be used in phase two to develop, pilot-test, and refine a survey instrument based upon the Theory of Planned Behaviour. In the third phase of the project, the final survey will be administered to a sample of the study population over the telephone. Analyses will include measures of sampling bias, reliability of the measures, construct validity, as well as multiple regression analyses to identify constructs and beliefs most salient to seniors' decisions about whether to attend CPR classes or perform CPR on a cardiac arrest victim. Discussion The results of this survey will provide valuable insight into factors influencing the interest in CPR training and performance among a targeted group of individuals most susceptible to

  7. GEP/GMP ratio by polarization transfer in (rvec e)p → e(rvec p)

    International Nuclear Information System (INIS)

    Mark Jones; Konrad Aniol; Baker, F.; Berthot, J.; Pierre Bertin; William Bertozzi; Auguste Besson; Louis Bimbot; Werner Boeglin; Edward Brash; Brown, D.; John Calarco; Lawrence Cardman; Chang, C.; Jian-Ping Chen; Eugene Chudakov; Steve Churchwell; Evaristo Cisbani; Daniel Dale; Raffaele De Leo; Alexandre Deur; Brian Diederich; John Domingo; Martin Epstein; Lars Ewell; Kevin Fissum; Fleck, A.; Helene Fonvieille; Salvatore Frullani; Juncai Gao; Franco Garibaldi; Ashot Gasparian; Gerstner, G. M.; Shalev Gilad; Ronald Gilman; Oleksandr Glamazdin; Charles Glashausser; Javier Gomez; Viktor Gorbenko; Alphonza Green; Jens-Ole Hansen; Calvin Howell; Garth Huber; Mauro Iodice; Cornelis de Jager; Stephanie Jaminion; Xiaodong Jiang; Kahl, William E.; James Kelly; Mohammad Khayat; Laird Kramer; Gerfried Kumbartzki; Michael Kuss; Lakuriki, E.; Geraud Laveissiere; John LeRose; Meihua Liang; Richard Lindgren; Nilanga Liyanage; George Lolos; Macri, R.; Richard Madey; Sergey Malov; Demetrius Margaziotis; Pete Markowitz; Kathy McCormick; Justin McIntyre; Meer, Rob van der; Robert Michaels; Brian Milbrath; Jean Mougey; Sirish Nanda; Ed Offermann; Zisis Papandreou; Charles Perdrisat; Gerassimos Petratos; Nikolai Piskunov; Roman Pomatsalyuk; David Prout; Vina Punjabi; Gilles Quemener; Ronald Ransome; Brian Raue; Yves Roblin; Julie Roche; Gary Rutledge; Paul Rutt; Arunava Saha; Teijiro Saito; Adam Sarty; Smith, T. P.; Sorokin, P.; Steffen Strauch; Riad Suleiman; Kazunori Takahashi; Jeffrey Templon; Luminita Todor; Paul Ulmer; Guido Urciuoli; Pascal Vernin; Branislav Vlahovic; Voskanian, H.; Krishni Wijesooriya; Bogdan Wojtsekhowski; Rhett Woo; Feng Xiong; Dan Zainea; Zilu Zhou

    2000-01-01

    The ratio of the proton's elastic electromagnetic form factors, G(E p )/G(M p ) was obtained by measuring P i and P l , the transverse and the longitudinal recoil proton polarization, respectively. For elastic ep to ep, G(E p )/G(M p ) is proportional to P t /P l . Simultaneous measurement of P t and P l in a polarimeter provides good control of the systematic uncertainty. The results for the ratio G(E p )/G(M p ) show a systematic decrease as Q 2 increases from 0.5 to 3.5 GeV 2 , indicating for the first time a definite difference in the spatial distribution of charge and magnetization currents in the proton

  8. Ratios of regioisomers of minor acylglycerols less polar than triricinolein in castor oil estimated by mass spectrometry

    Science.gov (United States)

    We have recently reported the identification of forty new minor molecular species of acylglycerols containing hydroxy fatty acids less polar than triricinolein by electrospray ionization mass spectrometry of the lithium adducts. The ratios of regioisomers of triacylglycerols (ABC and AAB types) and ...

  9. The effect of formal training of cardiopulmonary resuscitation (CPR skills on medical students perceived self-sufficiency

    Directory of Open Access Journals (Sweden)

    Shaghaghi A

    2004-07-01

    Full Text Available Background: Experience of cardiopulmonary resuscitation (CPR in real clinical setting is not easily possible for all medical students. Purpose: To assess medical student perceived self-sufficiency on three procedural skill on internship courses after they had taken a training course in clerkship period. Methods: Forty three medical students who had attended a workshop on CPR, tracheal intubations and venopuncture answered the questionnaires on their perceived self-sufficiency in performing these procedures after serving a few months as interns. Results: The mean score for perceived self-sufficiency (PSS was 75.84 (±18.63.Thre were a high correlation between the score given for the applicability of training in real life situation and the stress reduction scores on first time performing the procedure. Conclusion: The high degree of correlation between PSS scores and applicability scores, may warrant the consideration of new methods in procedural skills. Keywords: SKILL TRAINING, CPR TRAINING, PERCEIVED SELF-SUFFICIENCY

  10. The Two-Component System CprRS Senses Cationic Peptides and Triggers Adaptive Resistance in Pseudomonas aeruginosa Independently of ParRS

    DEFF Research Database (Denmark)

    Fernandez, Luca; Jenssen, Håvard; Bains, Manjeet

    2012-01-01

    dependency on the CprRS and ParRS systems in a concentration-dependent manner. It was further demonstrated that, following exposure to inducing antimicrobial peptides, cprRS mutants did not become adaptively resistant to polymyxins as was observed for wild-type cells. Our microarray studies demonstrated...

  11. Protocol of a Multicenter International Randomized Controlled Manikin Study on Different Protocols of Cardiopulmonary Resuscitation for laypeople (MANI-CPR).

    Science.gov (United States)

    Baldi, Enrico; Contri, Enrico; Burkart, Roman; Borrelli, Paola; Ferraro, Ottavia Eleonora; Tonani, Michela; Cutuli, Amedeo; Bertaia, Daniele; Iozzo, Pasquale; Tinguely, Caroline; Lopez, Daniel; Boldarin, Susi; Deiuri, Claudio; Dénéréaz, Sandrine; Dénéréaz, Yves; Terrapon, Michael; Tami, Christian; Cereda, Cinzia; Somaschini, Alberto; Cornara, Stefano; Cortegiani, Andrea

    2018-04-19

    Out-of-hospital cardiac arrest is one of the leading causes of death in industrialised countries. Survival depends on prompt identification of cardiac arrest and on the quality and timing of cardiopulmonary resuscitation (CPR) and defibrillation. For laypeople, there has been a growing interest on hands-only CPR, meaning continuous chest compression without interruption to perform ventilations. It has been demonstrated that intentional interruptions in hands-only CPR can increase its quality. The aim of this randomised trial is to compare three CPR protocols performed with different intentional interruptions with hands-only CPR. This is a prospective randomised trial performed in eight training centres. Laypeople who passed a basic life support course will be randomised to one of the four CPR protocols in an 8 min simulated cardiac arrest scenario on a manikin: (1) 30 compressions and 2 s pause; (2) 50 compressions and 5 s pause; (3) 100 compressions and 10 s pause; (4) hands-only. The calculated sample size is 552 people. The primary outcome is the percentage of chest compression performed with correct depth evaluated by a computerised feedback system (Laerdal QCPR). ETHICS AND DISSEMINATION: . Due to the nature of the study, we obtained a waiver from the Ethics Committee (IRCCS Policlinico San Matteo, Pavia, Italy). All participants will sign an informed consent form before randomisation. The results of this study will be published in peer-reviewed journal. The data collected will also be made available in a public data repository. NCT02632500. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Effects of pre-training using serious game technology on CPR performance – an exploratory quasi-experimental transfer study

    Directory of Open Access Journals (Sweden)

    Creutzfeldt Johan

    2012-12-01

    Full Text Available Abstract Background Multiplayer virtual world (MVW technology creates opportunities to practice medical procedures and team interactions using serious game software. This study aims to explore medical students’ retention of knowledge and skills as well as their proficiency gain after pre-training using a MVW with avatars for cardio-pulmonary resuscitation (CPR team training. Methods Three groups of pre-clinical medical students, n = 30, were assessed and further trained using a high fidelity full-scale medical simulator: Two groups were pre-trained 6 and 18 months before assessment. A reference control group consisting of matched peers had no MVW pre-training. The groups consisted of 8, 12 and 10 subjects, respectively. The session started and ended with assessment scenarios, with 3 training scenarios in between. All scenarios were video-recorded for analysis of CPR performance. Results The 6 months group displayed greater CPR-related knowledge than the control group, 93 (±11% compared to 65 (±28% (p  At start the pre-trained groups adhered better to guidelines than the control group; mean violations 0.2 (±0.5, 1.5 (±1.0 and 4.5 (±1.0 for the 6 months, 18 months and control group respectively. Likewise, in the 6 months group no chest compression cycles were delivered at incorrect frequencies whereas 54 (±44% in the control group (p  Conclusions This study supports the beneficial effects of MVW-CPR team training with avatars as a method for pre-training, or repetitive training, on CPR-skills among medical students.

  13. How well does the Continuous Plankton Recorder (CPR) sample zooplankton? A comparison with the Longhurst Hardy Plankton Recorder (LHPR) in the northeast Atlantic

    Science.gov (United States)

    Richardson, Anthony J.; John, Eurgain H.; Irigoien, Xabier; Harris, Roger P.; Hays, Graeme C.

    2004-09-01

    The Continuous Plankton Recorder (CPR) survey has collected data on basin-scale zooplankton abundance in the North Atlantic since the 1930s. These data have been used in many studies to elucidate seasonal patterns and long-term change in plankton populations, as well as more recently to validate ecosystem models. There has, however, been relatively little comparison of the data from the CPR with that from other samplers. In this study we compare zooplankton abundance estimated from the CPR in the northeast Atlantic with near-surface samples collected by a Longhurst-Hardy Plankton Recorder (LHPR) at Ocean Weather Station India (59°N, 19°W) between 1971 and 1975. Comparisons were made for six common copepods in the region: Acartia clausi, Calanus finmarchicus, Euchaeta norvegica, Metridia lucens, Oithona sp., and Pleuromamma robusta. Seasonal cycles based on CPR data were similar to those recorded by the LHPR. Differences in absolute abundances were apparent, however, with the CPR underestimating abundances by a factor of between 5 and 40, with the exception of A. clausi. Active avoidance by zooplankton is thought to be responsible. This avoidance is species specific, so that care must be taken describing communities, as the CPR emphasises those species that are preferentially caught, a problem common to many plankton samplers.

  14. An Appropriate Compression Pace is Important for Securing the Quality of Hands-only CPR : A manikin study

    OpenAIRE

    Shimizu, Yoshitaka; Tanigawa, Koichi; Ishikawa, Masami; Ouhara, Kazuhisa; Oue, Kana; Yoshinaka, Taiga; Kurihara, Hidemi; Irifune, Masahiro

    2014-01-01

    It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-secon...

  15. Abstract 20854: A Tale of Self-Fulfilling Prophecies in Out-of-Hospital Cardiac Arrest: Emergency Medical Technicians Deliberately Perform Substandard CPR When Anticipating Poor Prognosis

    DEFF Research Database (Denmark)

    Bødtker, Henrik; Klausen, Troels M; Lauridsen, Kasper G

    2017-01-01

    ) if they believe resuscitation to be futile. Furthermore, to investigate if different patient and resuscitation attempt characteristics result in EMTs deliberately performing substandard CPR.Methods: This was a cross-sectional questionnaire survey study conducted in 2016 through 2017 including EMTs from a Danish...... and compressions). Overall, 22% and 51% would perform substandard CPR if the patient were 80 or 90 years old respectively, 46% if the patient was living in a nursing home and up to 31% due to comorbidity such as cancer. EMTs (51%) would deliberately perform substandard CPR in case of on-going bystander CPR >20...... minutes. EMTs (72%) felt competent to terminate resuscitation, but only 9% knew international termination guidelines.Conclusion: EMTs delay start of resuscitation if they anticipate resuscitation to be futile. Furthermore, they deliberately perform substandard CPR based on controversial patient...

  16. Prevention of oral bacterial flora transmission by using mouth-to-mask ventilation during CPR.

    Science.gov (United States)

    Cydulka, R K; Connor, P J; Myers, T F; Pavza, G; Parker, M

    1991-01-01

    The Emergency Cardiac Care Committee of the American Heart Association has recently recommended utilizing protective barrier precautions during CPR (1,2). We assessed 17 mask and faceshield resuscitation devices for adequacy of barrier protection. Eight of the devices were faceshields (CPR Microshield, Hygenic, MedCare Mask, Resusci, Samaritan, Sealeasy, Portex); 8 were mask devices (Laerdal, Dyna Med, MTM Emergency Lung Ventilator, MTM Emergency Resuscitator, Res-Q-Flo, Rightway Mouth-to-Mask Resuscitation, Trufit), and one of the devices did not meet the criteria for either faceshield or mask (Lifesaver). All masks were disinfected, applied to the investigator's face as directed by the manufacturers' instructions, and then cultured for oral aerobic bacterial flora on the rescuer side. No mask devices cultured positive for oral aerobic bacterial flora, while 6 of 8 faceshield devices cultured positive for oral aerobic bacterial flora (P less than 0.007). The CPR Microshield and the Portex faceshield were the only devices that did not develop a positive culture. We conclude that all ventilation devices with a one-way valve, except the Sealeasy device, provide adequate barrier type protection from oral aerobic bacterial flora when simulating mouth-to-barrier type protection when performing mouth-to-mouth ventilation.

  17. Design of a 50/50 splitting ratio non-polarizing beam splitter based on the modal method with fused-silica transmission gratings

    Science.gov (United States)

    Zhao, Huajun; Yuan, Dairong; Ming, Hai

    2011-04-01

    The optical design of a beam splitter that has a 50/50 splitting ratio regardless of the polarization is presented. The non-polarizing beam splitter (NPBS) is based on the fused-silica rectangular transmission gratings with high intensity tolerance. The modal method has been used to estimate the effective index of the modes excited in the grating region for TE and TM polarizations. If a phase difference equals an odd multiples of π/2 for the first two modes (i.e. modes 0 and 1), the incident light will be diffracted into the 0 and -1 orders with about 50% and 50% diffraction efficiency for TM and TE polarizations, respectively.

  18. Keep pushing! Limiting interruptions to CPR; bag-valve mask versus i-gel® airway ventilation

    Directory of Open Access Journals (Sweden)

    Craig Vincent-Lambert

    2016-10-01

    Objectives: This pilot study evaluated how interruptions to chest compressions or hands-off time (HOT are affected by the placement of an i-gel® airway vs. simple BVM ventilation during single rescuer CPR. Method: 16 participants performed two, ten-minute single rescuer CPR simulations, firstly using the BVM and later the i-gel® airway for ventilation. Data pertaining to ventilations and HOT in each scenario was statistically analysed and compared. Results: The i-gel® airway demonstrated a superior ease of ventilation compared to BVM alone and resulted in a reduction of time spent on ventilations overall. The i-gel® however took a mean of 29 s, ± 10 s, to secure which contributes considerably to HOT. Conclusion: The use of the i-gel® airway resulted in a considerable decrease in the amount of time spent on ventilations and in more compressions being performed. The overall reduction in HOT was, however, offset by the time it took to secure the device. Further investigation into the use and securing of the i-gel® airway in single rescuer CPR is recommended.

  19. The impact of ultra-brief chest compression-only CPR video training on responsiveness, compression rate, and hands-off time interval among bystanders in a shopping mall.

    Science.gov (United States)

    Panchal, Ashish R; Meziab, Omar; Stolz, Uwe; Anderson, Wes; Bartlett, Mitchell; Spaite, Daniel W; Bobrow, Bentley J; Kern, Karl B

    2014-09-01

    Recent studies have demonstrated higher-quality chest compressions (CCs) following a 60 s ultra-brief video (UBV) on compression-only CPR (CO-CPR). However, the effectiveness of UBVs as a CPR-teaching tool for lay bystanders in public venues remains unknown. Determine whether an UBV is effective in teaching laypersons CO-CPR in a public setting and if viewing leads to superior responsiveness and CPR skills. Adult lay bystanders were enrolled in a public shopping mall and randomized to: (1) Control (CTR): sat idle for 60 s; (2) UBV: watched a 60 s UBV on CO-CPR. Subjects were read a scenario detailing a sudden collapse in the mall and asked to do what they "thought was best" on a mannequin. Performance measures were recorded for 2 min: responsiveness (time to call 911 and first CCs) and CPR quality [CC depth, rate, hands-off interval (time without CC after first CC)]. One hundred subjects were enrolled. Demographics were similar between groups. UBV subjects called 911 more frequently (percent difference: 31%) and initiated CCs sooner in the arrest scenario (median difference (MD): 5 s). UBV cohort had increased CC rate (MD: 19 cpm) and decreased hands-off interval (MD: 27 s). There was no difference in CC depth. Bystanders with UBV training in a shopping mall had significantly improved responsiveness, CC rate, and decreased hands-off interval. Given the short length of training, UBV may have potential as a ubiquitous intervention for public venues to help improve bystander reaction to arrest and CO-CPR performance. Published by Elsevier Ireland Ltd.

  20. 3:1 compression to ventilation ratio versus continuous chest compression with asynchronous ventilation in a porcine model of neonatal resuscitation.

    Science.gov (United States)

    Schmölzer, Georg M; O'Reilly, Megan; Labossiere, Joseph; Lee, Tze-Fun; Cowan, Shaun; Nicoll, Jessica; Bigam, David L; Cheung, Po-Yin

    2014-02-01

    In contrast to the resuscitation guidelines of children and adults, guidelines on neonatal resuscitation recommend synchronized 90 chest compressions with 30 manual inflations (3:1) per minute in newborn infants. The study aimed to determine if chest compression with asynchronous ventilation improves the recovery of bradycardic asphyxiated newborn piglets compared to 3:1 Compression:Ventilation cardiopulmonary resuscitation (CPR). Term newborn piglets (n=8/group) were anesthetized, intubated, instrumented and exposed to 45-min normocapnic hypoxia followed by asphyxia. Protocolized resuscitation was initiated when heart rate decreased to 25% of baseline. Piglets were randomized to receive resuscitation with either 3:1 compressions to ventilations (3:1C:V CPR group) or chest compressions with asynchronous ventilations (CCaV) or sham. Continuous respiratory parameters (Respironics NM3(®)), cardiac output, mean systemic and pulmonary artery pressures, and regional blood flows were measured. Piglets in 3:1C:V CPR and CCaV CPR groups had similar time to return of spontaneous circulation, survival rates, hemodynamic and respiratory parameters during CPR. The systemic and regional hemodynamic recovery in the subsequent 4h was similar in both groups and significantly lower compared to sham-operated piglets. Newborn piglets resuscitated by CCaV had similar return of spontaneous circulation, survival, and hemodynamic recovery compared to those piglets resuscitated by 3:1 Compression:Ventilation ratio. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. The ratio R = dσL/dσT in heavy-quark pair leptoproduction as a probe of linearly polarized gluons in unpolarized proton

    Science.gov (United States)

    Efremov, A. V.; Ivanov, N. Ya.; Teryaev, O. V.

    2018-05-01

    We study the Callan-Gross ratio R = dσL / dσT in heavy-quark pair leptoproduction, lN →l‧ Q Q bar X, as a probe of linearly polarized gluons inside unpolarized proton, where dσT (dσL) is the differential cross section of the γ* N → Q Q bar X process initiated by a transverse (longitudinal) virtual photon. Note first that the maximal value for the quantity R allowed by the photon-gluon fusion with unpolarized gluons is large, about 2. We calculate the contribution of the transverse-momentum dependent gluonic counterpart of the Boer-Mulders function, h1 ⊥g , describing the linear polarization of gluons inside unpolarized proton. Our analysis shows that the maximum value of the ratio R depends strongly on the gluon polarization; it varies from 0 to Q2/4m2 depending on h1⊥g . We conclude that the Callan-Gross ratio in heavy-quark pair leptoproduction is predicted to be large and very sensitive to the contribution of linearly polarized gluons. For this reason, future measurements of the longitudinal and transverse components of the charm and bottom production cross sections at the proposed EIC and LHeC colliders seem to be very promising for determination of the linear polarization of gluons inside unpolarized proton.

  2. The Effects of Visual Feedback on CPR Skill Retention in Graduate Student Athletic Trainers

    Directory of Open Access Journals (Sweden)

    Michael G. Miller

    2015-09-01

    Full Text Available Context: Studies examining the effectiveness of cardiopulmonary resuscitation (CPR chest compressions have found compression depth and rate to be less than optimal and recoil to full release to be incomplete. Objective: To determine if visual feedback affects the rate and depth of chest compressions and chest recoil values during CPR training of athletic trainers and to determine retention of proficiency over time. Design: Pre-test, post-test. Setting: Medical simulation laboratory. Participants: Eleven females and one male (23.08+.51 years old, from an Athletic Training Graduate Program. All participants were Certified Athletic Trainers (1.12+.46 years of experience and certified in CPR for the Professional Rescuer. Interventions: Participants completed a pre-test, practice sessions, and a post-test on a SimMan® (Laerdal Medical manikin with visual feedback of skills in real time. After the pre-test, participants received feedback by the investigators. Participants completed practice sessions as needed (range=1-4 sessions, until they reached 100% skill proficiency. After achieving proficiency, participants returned 8 weeks later to perform the CPR skills. Main Outcome Measures: The average of all compression outcome measures (rate, depth, recoil was captured every 10 seconds (6x per min. All participants performed 5 cycles of 30 compressions. A two-tailed paired samples t-test (pre to post was used to compare rate of chest compressions, depth of chest compressions, and recoil of the chest. Significance was set a priori at pResults: There was a significant difference between pre and post-test compression depth average, p=.002. The pre-depth average was 41mm + 9.83mm compared to the post-depth average of 52.26mm + 5mm. There were no significant differences between pre and post-test chest compression rates and recoil. Conclusions: The use of a simulated manikin with visual feedback facilitated participants to reach the recommended compression

  3. Design and transient analyses of emergency passive residual heat removal system of CPR1000

    International Nuclear Information System (INIS)

    Zhang, Y.P.; Qiu, S.Z.; Su, G.H.; Tian, W.X.

    2012-01-01

    Highlights: ► Designing an EPRHRs for CPR1000. ► Developing a RELAP model of the EPRHRs. ► The EPRHRs could take away the decay heat effectively. - Abstract: The steam generator secondary emergency passive residual heat removal system (EPRHRs) is a new design for traditional generation II + reactor CPR1000. The EPRHRs is designed to improve the safety and reliability of CPR1000 by completely or partially replacing traditional emergency water cooling system in the event of the station blackout or loss of heat sink accident. The EPRHRs consists of steam generator (SG), heat exchanger (HX), emergency makeup tank (EMT), cooling water tank (CWT), and corresponding pipes and valves. In order to improve the safety and reliability of CPR1000, the model of the primary loop and the EPRHRs was developed to investigate residual heat removal capability of the EPRHRs and the transient characteristics of the primary loop affected by the EPRHRs using RELAP5/MOD3.4. The transient characteristics of the primary loop and the EPRHRs were calculated in the event of station blackout accident. Sensitivity studies of the EPRHRs were also conducted to investigate the response of the primary loop and the EPRHRs on the main parameters of the EPRHRs. The EPRHRs could supply water to the SG shell side from the EMT successfully. The calculation results showed that the EPRHRs could take away the decay heat from the primary loop effectively, and that the single-phase and two-phase natural circulations were established in the primary loop and EPRHRs loop, respectively. The results also indicated that the effect of isolation valve open time on the transient characteristics of the primary loop was little. However, the effect of isolation valve open time on the EPRHRs condensate flow was relatively greater. The isolation valves should not be opened too rapidly during the isolation valve opening process, and the isolation valve opening time should be greater than 10 s, which could avoid the

  4. Real-time photonic sampling with improved signal-to-noise and distortion ratio using polarization-dependent modulators

    Science.gov (United States)

    Liang, Dong; Zhang, Zhiyao; Liu, Yong; Li, Xiaojun; Jiang, Wei; Tan, Qinggui

    2018-04-01

    A real-time photonic sampling structure with effective nonlinearity suppression and excellent signal-to-noise ratio (SNR) performance is proposed. The key points of this scheme are the polarization-dependent modulators (P-DMZMs) and the sagnac loop structure. Thanks to the polarization sensitive characteristic of P-DMZMs, the differences between transfer functions of the fundamental signal and the distortion become visible. Meanwhile, the selection of specific biases in P-DMZMs is helpful to achieve a preferable linearized performance with a low noise level for real-time photonic sampling. Compared with the quadrature-biased scheme, the proposed scheme is capable of valid nonlinearity suppression and is able to provide a better SNR performance even in a large frequency range. The proposed scheme is proved to be effective and easily implemented for real time photonic applications.

  5. A third-order gas-kinetic CPR method for the Euler and Navier-Stokes equations on triangular meshes

    Science.gov (United States)

    Zhang, Chao; Li, Qibing; Fu, Song; Wang, Z. J.

    2018-06-01

    A third-order accurate gas-kinetic scheme based on the correction procedure via reconstruction (CPR) framework is developed for the Euler and Navier-Stokes equations on triangular meshes. The scheme combines the accuracy and efficiency of the CPR formulation with the multidimensional characteristics and robustness of the gas-kinetic flux solver. Comparing with high-order finite volume gas-kinetic methods, the current scheme is more compact and efficient by avoiding wide stencils on unstructured meshes. Unlike the traditional CPR method where the inviscid and viscous terms are treated differently, the inviscid and viscous fluxes in the current scheme are coupled and computed uniformly through the kinetic evolution model. In addition, the present scheme adopts a fully coupled spatial and temporal gas distribution function for the flux evaluation, achieving high-order accuracy in both space and time within a single step. Numerical tests with a wide range of flow problems, from nearly incompressible to supersonic flows with strong shocks, for both inviscid and viscous problems, demonstrate the high accuracy and efficiency of the present scheme.

  6. Single-Layer, Dual-Port, Dual-Band, and Orthogonal-Circularly Polarized Microstrip Antenna Array with Low Frequency Ratio

    Directory of Open Access Journals (Sweden)

    Min Wang

    2018-01-01

    Full Text Available A single-layer, dual-port, dual-band, and dual circularly polarized (CP microstrip array is designed for satellite communication in this paper. The operating frequencies are 8.2 and 8.6 GHz with a very low ratio of 1.05. First, a rectangular patch element is fed through microstrip lines at two orthogonal edges to excite two orthogonal dominant modes of TM01 and TM10. The very low frequency ratio can be realized with high polarization isolations. Then, a 2-by-2 dual-band dual-CP subarray is constructed by two independent sets of sequentially rotated (SR feed structures. An 8-by-8 array is designed on the single-layer thin substrate. Finally, by utilizing one-to-four power dividers and semirigid coaxial cables, a 16-by-16 array is developed to achieve higher gain. Measured results show that the 16-by-16 array has 15 dB return loss (RL bandwidths of 4.81% and 6.75% and 3 dB axial ratio (AR bandwidths of 2.84% and 1.57% in the lower and the upper bands, respectively. Isolations of 18.6 dB and 19.4 dB and peak gains of 25.1 dBic and 25.6 dBic are obtained at 8.2 and 8.6 GHz, respectively.

  7. Effect of an interactive cardiopulmonary resuscitation assist device with an automated external defibrillator synchronised with a ventilator on the CPR performance of emergency medical service staff: a randomised simulation study.

    Science.gov (United States)

    Nitzschke, Rainer; Doehn, Christoph; Kersten, Jan F; Blanz, Julian; Kalwa, Tobias J; Scotti, Norman A; Kubitz, Jens C

    2017-04-04

    The present study evaluates whether the quality of advanced cardiac life support (ALS) is improved with an interactive prototype assist device. This device consists of an automated external defibrillator linked to a ventilator and provides synchronised visual and acoustic instructions for guidance through the ALS algorithm and assistance for face-mask ventilations. We compared the cardiopulmonary resuscitation (CPR) quality of emergency medical system (EMS) staff members using the study device or standard equipment in a mannequin simulation study with a prospective, controlled, randomised cross-over study design. Main outcome was the effect of the study device compared to the standard equipment and the effect of the number of prior ALS trainings of the EMS staff on the CPR quality. Data were analysed using analyses of covariance (ANCOVA) and binary logistic regression, accounting for the study design. In 106 simulations of 56 two-person rescuer teams, the mean hands-off time was 24.5% with study equipment and 23.5% with standard equipment (Difference 1.0% (95% CI: -0.4 to 2.5%); p = 0.156). With both types of equipment, the hands-off time decreased with an increasing cumulative number of previous CPR trainings (p = 0.042). The study equipment reduced the mean time until administration of adrenaline (epinephrine) by 23 s (p = 0.003) and that of amiodarone by 17 s (p = 0.016). It also increased the mean number of changes in the person doing chest compressions (0.6 per simulation; p < 0.001) and decreased the mean number of chest compressions (2.8 per minute; p = 0.022) and the mean number of ventilations (1.8 per minute; p < 0.001). The chance of administering amiodarone at the appropriate time was higher, with an odds ratio of 4.15, with the use of the study equipment CPR.com compared to the standard equipment (p = 0.004). With an increasing number of prior CPR trainings, the time intervals in the ALS algorithm until the

  8. Role of dominant versus non-dominant hand position during uninterrupted chest compression CPR by novice rescuers: a randomized double-blind crossover study.

    Science.gov (United States)

    Nikandish, Reza; Shahbazi, Sharbanoo; Golabi, Sedigheh; Beygi, Najimeh

    2008-02-01

    Previous research has suggested improved quality of chest compressions when the dominant hand was in contact with the sternum. However, the study was in health care professionals and during conventional chest compression-ventilation CPR. The aim of this study was to test the hypothesis, in null form, that the quality of external chest compressions (ECC) in novice rescuers during 5min of uninterrupted chest compression CPR (UCC-CPR) is independent of the hand in contact with the sternum. Confirmation of the hypothesis would allow the use of either hand by the novice rescuers during UCC-CPR. Fifty-nine first year public heath students participated in this randomised double-blind crossover study. After completion of a standard adult BLS course, they performed single rescuer adult UCC-CPR for 5 min on a recording Resusci Anne. One week later they changed the hand of contact with the sternum while performing ECC. The quality of ECC was recorded by the skill meter for the dominant and non-dominant hand during 5 min ECC. The total number of correct chest compressions in the dominant hand group (DH), mean 183+/-152, was not statistically different from the non-dominant hand group (NH), mean 152+/-135 (P=0.09). The number of ECC with inadequate depth in the DH group, mean 197+/-174 and NH group, mean 196+/-173 were comparable (P=0.1). The incidence of ECC exceeding the recommended depth in the DH group, mean 51+/-110 and NH group, mean 32+/-75 were comparable (P=0.1). Although there is a trend to increased incidence of correct chest compressions with positioning the dominant hand in contact with the sternum, it does not reach statistical significance during UCC-CPR by the novice rescuers for 5 min.

  9. A new method to detect cerebral blood flow waveform in synchrony with chest compression by near-infrared spectroscopy during CPR.

    Science.gov (United States)

    Koyama, Yasuaki; Wada, Takafumi; Lohman, Brandon D; Takamatsu, Yuka; Matsumoto, Junichi; Fujitani, Shigeki; Taira, Yasuhiko

    2013-10-01

    The objective of the study is to demonstrate the utility of near-infrared spectroscopy (NIRS) in evaluating chest compression (CC) quality in cardiac arrest (CA) patients as well as determine its prognosis predictive value. We present a nonconsecutive case series of adult patients with CA whose cardiopulmonary resuscitation (CPR) was monitored with NIRS and collected the total hemoglobin concentration change (ΔcHb), the tissue oxygen index (TOI), and the ΔTOI to assess CC quality in a noninvasive fashion. During CPR, ΔcHb displayed waveforms monitor, which we regarded as a surrogate for CC quality. Total hemoglobin concentration change waveforms responded accurately to variations or cessations of CCs. In addition, a TOI greater than 40% measured upon admission appears to be significant in predicting patient's outcome. Of 15 patients, 6 had a TOI greater than 40% measured upon admission, and 67% of the latter were in return of spontaneous circulation after CPR and were found to be significantly different between return of spontaneous circulation and death (P = .047; P < .05). Near-infrared spectroscopy reliably assesses the quality of CCs in patients with CA demonstrated by synchronous waveforms during CPR and possible prognostic predictive value, although further investigation is warranted. © 2013 Elsevier Inc. All rights reserved.

  10. Added value of cerebro-placental ratio and uterine artery Doppler at routine third trimester screening as a predictor of SGA and FGR in non-selected pregnancies.

    Science.gov (United States)

    Rial-Crestelo, M; Martinez-Portilla, R J; Cancemi, A; Caradeux, J; Fernandez, L; Peguero, A; Gratacos, E; Figueras, Francesc

    2018-03-04

    The objective of this study is to determine the added value of cerebroplacental ratio (CPR) and uterine Doppler velocimetry at third trimester scan in an unselected obstetric population to predict smallness and growth restriction. We constructed a prospective cohort study of women with singleton pregnancies attended for routine third trimester screening (32 +0 -34 +6 weeks). Fetal biometry and fetal-maternal Doppler ultrasound examinations were performed by certified sonographers. The CPR was calculated as a ratio of the middle cerebral artery to the umbilical artery pulsatility indices. Both attending professionals and patients were blinded to the results, except in cases of estimated fetal weight < p10. The association between third trimester Doppler parameters and small for gestational age (SGA) (birth weight <10th centile) and fetal growth restriction (FGR) (birth weight below the third centile) was assessed by logistic regression, where the basal comparison was a model comprising maternal characteristics and estimated fetal weight (EFW). A total of 1030 pregnancies were included. The mean gestational age at scan was 33 weeks (SD 0.6). The addition of CPR and uterine Doppler to maternal characteristics plus EFW improved the explained uncertainty of the predicting models for SGA (15 versus 10%, p < .001) and FGR (12 versus 8%, p = .03). However, the addition of CPR and uterine Doppler to maternal characteristics plus EFW only marginally improved the detection rates for SGA (38 versus 34% for a 10% of false positives) and did not change the predictive performance for FGR. The added value of CPR and uterine Doppler at 33 weeks of gestation for detecting defective growth is poor.

  11. Importance of basic CPR techniques. A study in the Region of Murcia

    Directory of Open Access Journals (Sweden)

    J. Arturo Abraldes Valeiras

    2011-01-01

    Full Text Available Annually in Spain many people die from diseases related to heart. Heart attack is the main cause of such deaths. Know and control the basic techniques of basic Cardiopulmonary resuscitation (CPR are essential to help a person away from these features. This study examined 1 the importance of knowing these techniques in the general population, and 2 the perception of the difficulty of understanding and application of techniques. We used a questionnaire designed "ad hoc" as a tool for collecting information. The instrument was subjected to validation and reliability for the study. The questionnaire was completed by 235 volunteers aged between 10 and 65. We performed a descriptive analysis, based on gender and the variables importance of knowledge and learning / apply techniques. Among the most relevant results, we emphasize an interest of society to improve training in this type of knowledge. Training would be ideal in most age groups of people (teens to seniors. Likewise, CPR techniques are easy to understand and execute a lesser extent, relevant perception among people who acknowledge and application these techniques

  12. The effect on quality of chest compressions and exhaustion of a compression--ventilation ratio of 30:2 versus 15:2 during cardiopulmonary resuscitation--a randomised trial

    NARCIS (Netherlands)

    Deschilder, Koen; de Vos, Rien; Stockman, Willem

    2007-01-01

    Recent cardio pulmonary resuscitation (CPR) guidelines changed the compression:ventilation ratio in 30:2. To compare the quality of chest compressions and exhaustion using the ratio 30:2 versus 15:2. A prospective, randomised crossover design was used. Subjects were recruited from the H.-Hart

  13. Journal of Earth System Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    The LRO data in terms of the scattering coefficient (°LH and °LV) with incidence angle of 49° has been used for computing physical and electrical parameter of lunar surface and to learn more about the impact cratering process. Most of the lunar surface shows small Circular Polarization Ratio (CPR), i.e., the reversal of ...

  14. "Utstein style" spreadsheet and database programs based on Microsoft Excel and Microsoft Access software for CPR data management of in-hospital resuscitation.

    Science.gov (United States)

    Adams, Bruce D; Whitlock, Warren L

    2004-04-01

    In 1997, The American Heart Association in association with representatives of the International Committee on Resuscitation (ILCOR) published recommended guidelines for reviewing, reporting and conducting in-hospital cardiopulmonary resuscitation (CPR) outcomes using the "Utstein style". Using these guidelines, we developed two Microsoft Office based database management programs that may be useful to the resuscitation community. We developed a user-friendly spreadsheet based on MS Office Excel. The user enters patient variables such as name, age, and diagnosis. Then, event resuscitation variables such as time of collapse and CPR team arrival are entered from a "code flow sheet". Finally, outcome variables such as patient condition at different time points are recorded. The program then makes automatic calculations of average response times, survival rates and other important outcome measurements. Also using the Utstein style, we developed a database program based on MS Office Access. To promote free public access to these programs, we established at a website. These programs will help hospitals track, analyze, and present their CPR outcomes data. Clinical CPR researchers might also find the programs useful because they are easily modified and have statistical functions.

  15. Prognostic factors for death and survival with or without complications in cardiac arrest patients receiving CPR within 24 hours of anesthesia for emergency surgery

    Directory of Open Access Journals (Sweden)

    Siriphuwanun V

    2014-10-01

    Full Text Available Visith Siriphuwanun,1 Yodying Punjasawadwong,1 Worawut Lapisatepun,1 Somrat Charuluxananan,2 Ketchada Uerpairojkit2 1Department of Anesthesiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 2Department of Anesthesiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand Purpose: To determine prognostic factors for death and survival with or without complications in cardiac arrest patients who received cardiopulmonary resuscitation (CPR within 24 hours of receiving anesthesia for emergency surgery. Patients and methods: A retrospective cohort study approved by the Maharaj Nakorn Chiang Mai University Hospital Ethical Committee. Data used were taken from records of 751 cardiac arrest patients who received their first CPR within 24 hours of anesthesia for emergency surgery between January 1, 2003 and October 31, 2011. The reviewed data included patient characteristics, surgical procedures, American Society of Anesthesiologist (ASA physical status classification, anesthesia information, the timing of cardiac arrest, CPR details, and outcomes at 24 hours after CPR. Univariate and polytomous logistic regression analyses were used to determine prognostic factors associated with the outcome variable. P-values of less than 0.05 were considered statistically significant. Results: The outcomes at 24 hours were death (638/751, 85.0%, survival with complications (73/751, 9.7%, and survival without complications (40/751, 5.3%. The prognostic factors associated with death were: age between 13–34 years (OR =3.08, 95% CI =1.03–9.19; ASA physical status three and higher (OR =6.60, 95% CI =2.17–20.13; precardiopulmonary comorbidity (OR =3.28, 95% CI =1.09–9.90; the condition of patients who were on mechanical ventilation prior to receiving anesthesia (OR =4.11, 95% CI =1.17–14.38; surgery in the upper abdominal site (OR =14.64, 95% CI =2.83–75.82; shock prior to cardiac arrest (OR =6.24, 95% CI =2.53–15

  16. Bench evaluation: three face-shield CPR barrier devices.

    Science.gov (United States)

    Simmons, M; Deao, D; Moon, L; Peters, K; Cavanaugh, S

    1995-06-01

    Due to the fear of disease transmission, the practice of mouth-to-mouth (M-M) rescue breathing is rarely performed; to address this concern, many types of CPR barrier devices have been developed. These include bag-valve-mask devices, mouth-to-mask devices, and face shields (FS). The purpose of this study was to measure the volumes delivered during mouth-to-face shield (M-FS) breathing, to measure the back pressure and calculate the resistance to flow through their 1-way valves, and to test for backward leak of gas through the valves. Three FS brands were evaluated: Kiss of Life (KOL), MicroSHIELD (Micro) and Res-Cue Key (RCK). Volume delivered during M-M and M-FS breathing was evaluated by 10 rescuers who used the devices while performing rescue breathing on a CPR mannequin. Back pressure was measured and resistance calculated by directing airflow through the 1-way valves. Backward leak was evaluated by measuring the O2 concentration at the rescuer side of the valve while 100% O2 was directed toward the patient side of the valve. Differences among the brands were evaluated using analysis of variance. The mean (SD) values for volumes in L were: M-M 1.00 (0.25), Micro 0.77 (0.20), RCK 0.64 (0.10), and KOL 0.24 (0.11). Mean values for back pressure in cm H2O at 50 L/min were Micro 16.7 (1.29), KOL 7.22 (0.13), and RCK 2.15 (0.16). Significant backward leak only occurred with RCK. Not one of the FSs tested met all of the requirements suggested by the American Heart Association and by the International Standards Organization.

  17. Expression, purification, crystallization and preliminary X-ray analysis of conjugated polyketone reductase C2 (CPR-C2) from Candida parapsilosis IFO 0708.

    Science.gov (United States)

    Yamamura, Akihiro; Maruoka, Shintaro; Ohtsuka, Jun; Miyakawa, Takuya; Nagata, Koji; Kataoka, Michihiko; Kitamura, Nahoko; Shimizu, Sakayu; Tanokura, Masaru

    2009-11-01

    Conjugated polyketone reductase C2 (CPR-C2) from Candida parapsilosis IFO 0708 is a member of the NADPH-dependent aldo-keto reductase (AKR) superfamily and catalyzes the stereospecific reduction of ketopantoyl lactone to d-pantoyl lactone. A diffraction-quality crystal of recombinant CPR-C2 was obtained by the sitting-drop vapour-diffusion method using PEG 3350 as the precipitant. The crystal diffracted X-rays to 1.7 angstrom resolution on beamline NW12A of the Photon Factory-Advanced Ring (Tsukuba, Japan). The crystal belonged to space group P2(1)2(1)2(1), with unit-cell parameters a = 55.02, b = 68.30, c = 68.93 angstrom. The Matthews coefficient (V(M) = 1.76 angstrom(3) Da(-1)) indicated that the crystal contained one CPR-C2 molecule per asymmetric unit.

  18. Scattering of electromagnetic waves from a half-space of randomly distributed discrete scatterers and polarized backscattering ratio law

    Science.gov (United States)

    Zhu, P. Y.

    1991-01-01

    The effective-medium approximation is applied to investigate scattering from a half-space of randomly and densely distributed discrete scatterers. Starting from vector wave equations, an approximation, called effective-medium Born approximation, a particular way, treating Green's functions, and special coordinates, of which the origin is set at the field point, are used to calculate the bistatic- and back-scatterings. An analytic solution of backscattering with closed form is obtained and it shows a depolarization effect. The theoretical results are in good agreement with the experimental measurements in the cases of snow, multi- and first-year sea-ice. The root product ratio of polarization to depolarization in backscattering is equal to 8; this result constitutes a law about polarized scattering phenomena in the nature.

  19. An analysis of the efficacy of bag-valve-mask ventilation and chest compression during different compression-ventilation ratios in manikin-simulated paediatric resuscitation.

    Science.gov (United States)

    Kinney, S B; Tibballs, J

    2000-01-01

    The ideal chest compression and ventilation ratio for children during performance of cardiopulmonary resuscitation (CPR) has not been determined. The efficacy of chest compression and ventilation during compression ventilation ratios of 5:1, 10:2 and 15:2 was examined. Eighteen nurses, working in pairs, were instructed to provide chest compression and bag-valve-mask ventilation for 1 min with each ratio in random on a child-sized manikin. The subjects had been previously taught paediatric CPR within the last 3 or 5 months. The efficacy of ventilation was assessed by measurement of the expired tidal volume and the number of breaths provided. The rate of chest compression was guided by a metronome set at 100/min. The efficacy of chest compressions was assessed by measurement of the rate and depth of compression. There was no significant difference in the mean tidal volume or the percentage of effective chest compressions delivered for each compression-ventilation ratio. The number of breaths delivered was greatest with the ratio of 5:1. The percentage of effective chest compressions was equal with all three methods but the number of effective chest compressions was greatest with a ratio of 5:1. This study supports the use of a compression-ventilation ratio of 5:1 during two-rescuer paediatric cardiopulmonary resuscitation.

  20. Corpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    S. Eichhorn

    2017-01-01

    Full Text Available According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR with an established system (LUCAS II in a pig model. Methods. Pigs (n = 5/group in provoked ventricular fibrillation were left untreated for 5 minutes, after which 15 min of cardiopulmonary resuscitation was performed with chest compressions. After 15 min, defibrillation was performed every 2 min if necessary, and up to 3 doses of adrenaline were given. If there was no return of spontaneous circulation after 25 min, the experiment was terminated. Coronary perfusion pressure, carotid blood flow, end-expiratory CO2, regional oxygen saturation by near infrared spectroscopy, blood gas, and local organ perfusion with fluorescent labelled microspheres were measured at baseline and during resuscitation. Results. Animals treated with Corpuls CPR had significantly higher mean arterial pressures during resuscitation, along with a detectable trend of greater carotid blood flow and organ perfusion. Conclusion. Chest compressions with the Corpuls CPR device generated significantly higher mean arterial pressures than compressions performed with the LUCAS II device.

  1. Evaluation of a Brief Intervention Designed to Increase CPR Training among Pregnant Pool Owners

    Science.gov (United States)

    Girasek, Deborah C.

    2011-01-01

    This study evaluated whether a brief videotape could motivate pregnant pool owners to be trained in infant/child cardiopulmonary resuscitation (CPR). Women were recruited from prenatal classes in South Florida. Eligible volunteers were randomized to view a video or receive standard treatment, after completing a questionnaire. The video explained…

  2. Training and Confidence Level of Junior Anaesthetists in CPR- Experience in A Developing Country

    Directory of Open Access Journals (Sweden)

    Desalu Ibironke

    2008-01-01

    There is low confidence among junior anaesthetists in Nigeria in performance of CPR, poor knowledge of ECG interpretation of cardiac arrest rhythm and little practice in defibrillation. The establishment of a Resuscitation council would ensure adequate and frequent training which would improve knowledge, boost confidence and result in better patient care.

  3. Effects of Mg/Ga and V/III source ratios on hole concentration of N-polar (000\\bar{1}) p-type GaN grown by metalorganic vapor phase epitaxy

    Science.gov (United States)

    Nonoda, Ryohei; Shojiki, Kanako; Tanikawa, Tomoyuki; Kuboya, Shigeyuki; Katayama, Ryuji; Matsuoka, Takashi

    2016-05-01

    The effects of growth conditions such as Mg/Ga and V/III ratios on the properties of N-polar (000\\bar{1}) p-type GaN grown by metalorganic vapor phase epitaxy were studied. Photoluminescence spectra from Mg-doped GaN depended on Mg/Ga and V/III ratios. For the lightly doped samples, the band-to-acceptor emission was observed at 3.3 eV and its relative intensity decreased with increasing V/III ratio. For the heavily doped samples, the donor-acceptor pair emission was observed at 2.8 eV and its peak intensity monotonically decreased with V/III ratio. The hole concentration was maximum for the Mg/Ga ratio. This is the same tendency as in group-III polar (0001) growth. The V/III ratio also reduced the hole concentration. The higher V/III ratio reduced the concentration of residual donors such as oxygen by substituting nitrogen atoms. The surface became rougher with increasing V/III ratio and the hillock density increased.

  4. When to Stop CPR and When to Perform Rhythm Analysis: Potential Confusion Among ACLS Providers.

    Science.gov (United States)

    Giberson, Brandon; Uber, Amy; F Gaieski, David; Miller, Joseph B; Wira, Charles; Berg, Katherine; Giberson, Tyler; Cocchi, Michael N; S Abella, Benjamin; Donnino, Michael W

    2016-09-01

    Health care providers nationwide are routinely trained in Advanced Cardiac Life Support (ACLS), an American Heart Association program that teaches cardiac arrest management. Recent changes in the ACLS approach have de-emphasized routine pulse checks in an effort to promote uninterrupted chest compressions. We hypothesized that this new ACLS algorithm may lead to uncertainty regarding the appropriate action following detection of a pulse during a cardiac arrest. We conducted an observational study in which a Web-based survey was sent to ACLS-trained medical providers at 4 major urban tertiary care centers in the United States. The survey consisted of 5 multiple-choice, scenario-based ACLS questions, including our question of interest. Adult staff members with a valid ACLS certification were included. A total of 347 surveys were analyzed. The response rate was 28.1%. The majority (53.6%) of responders were between 18 and 32 years old, and 59.9% were female. The majority (54.2%) of responders incorrectly stated that they would continue CPR and possibly administer additional therapies when a team member detects a pulse immediately following defibrillation. Secondarily, only 51.9% of respondents correctly chose to perform a rhythm check following 2 minutes of CPR. The other 3 survey questions were correctly answered an average of 89.1% of the time. Confusion exists regarding whether or not CPR and cardiac medications should be continued in the presence of a pulse. Education may be warranted to emphasize avoiding compressions and medications when a palpable pulse is detected. © The Author(s) 2014.

  5. A Unified Electronic Tool for CPR and Emergency Treatment Escalation Plans Improves Communication and Early Collaborative Decision Making for Acute Hospital Admissions.

    Science.gov (United States)

    Johnson, Mae; Whyte, Martin; Loveridge, Robert; Yorke, Richard; Naleem, Shairana

    2017-01-01

    The National Confidential Enquiry into Patient Outcomes and Death (NCEPOD) report 'Time to Intervene' (2012) stated that in a substantial number of cases, resuscitation is attempted when it was thought a 'do not attempt cardiopulmonary resuscitation' (DNACPR) decision should have been in place. Early decisions about CPR status and advance planning about limits of care now form part of national recommendations by the UK Resuscitation Council (2016). Treatment escalation plans (TEP) document what level of treatment intervention would be appropriate if a patient were to become acutely unwell and were not previously formally in place at King's College Hospital. A unifying paper based form was successfully piloted in the Acute Medical Unit, introducing the TEP and bringing together decision making around both treatment escalation and CPR status. Subsequently an electronic order-set for CPR status and treatment escalation was launched in April 2015 which led to a highly visible CPR and escalation status banner on the main screen at the top of the patient's electronic record. Ultimately due to further iterations in the electronic process by December 2016, all escalation decisions for acutely admitted patients now have high quality supporting, explanatory documentation with 100% having TEPs in place. There is now widespread multidisciplinary engagement in the process of defining limits of care for acutely admitted medical patients within the first 14 hours of admission and a strategy for rolling this process out across all the divisions of the hospital through our Deteriorating Patient Group (DPG). The collaborative design with acute medical, palliative and intensive care teams and the high visibility provided by the electronic process in the Electronic Patient Record (EPR) has enhanced communication with these teams, patients, nursing staff and the multidisciplinary team by ensuring clarity through a universally understood process about escalation and CPR. Clarity and

  6. Apps4CPR: A review study of mobile applications for cardiopulmonary resuscitation training and support

    NARCIS (Netherlands)

    Kalz, Marco

    2013-01-01

    Kalz, M. (2013, 23 September). Apps4CPR: A review study of mobile applications for cardiopulmonary resuscitation training and support. Presentation given during the 6th World Congress on Social Media, Mobile Apps and Internet/Web 2.0 in Medicine, Health, and Biomedical Research, London, UK.

  7. Out-of-hospital cardiac arrest: the prospect of E-CPR in the Maastricht region.

    Science.gov (United States)

    Sharma, A S; Pijls, R W M; Weerwind, P W; Delnoij, T S R; de Jong, W C; Gorgels, A P M; Maessen, J G

    2016-02-01

    The current outcome of out-of-hospital cardiac arrest (OHCA) patients in the Maastricht region was analysed with the prospect of implementing extracorporeal cardiopulmonary resuscitation (E-CPR). A retrospective analysis of adult patients who were resuscitated for OHCA during a 24-month period was performed. 195 patients (age 66 [57-75] years, 82 % male) were resuscitated for OHCA by the emergency medical services and survived to admission at the emergency department. Survival to hospital discharge was 46.2 %. Notable differences between non-survivors and survivors were observed and included: age (70 [58-79] years) vs. (63 [55-72] years, p = 0.01), chronic heart failure (18 vs. 7 %, p = 0.02), shockable rhythm (67 vs. 99 %, p < 0.01), and return of spontaneous circulation (ROSC) at departure from the site of the arrest (46 vs. 99 %, p < 0.01) and on arrival to the emergency department (43 vs. 98 %, p < 0.01), respectively. Acute coronary syndrome was diagnosed in 32 % of non-survivors vs. 59 % among survivors, p < 0.01. Therapeutic hypothermia was provided in non-survivors (20 %) vs. survivors (43 %), p < 0.01. Percutaneous coronary intervention (PCI) was performed in 14 % of non-survivors while 52 % of survivors received PCI (p < 0.01). No statistical significance was observed in terms of gender, witnessed arrest, bystander CPR, or automated external defibrillator deployed among the cohort. At hospital discharge, moderately severe neurological disability was present in six survivors. These observations are compatible with the notion that a shockable rhythm, ROSC, and post-arrest care improve survival outcome. Potentially, initiating E-CPR in the resuscitation phase in patients with a shockable rhythm and no ROSC might serve as a bridge to definite treatment and improve survival outcome.

  8. Emergency nurses' current practices and understanding of family presence during CPR.

    LENUS (Irish Health Repository)

    Madden, Eilis

    2012-02-03

    PURPOSE: To examine emergency nurses\\' current practices and understanding of family presence during CPR in the emergency department, Cork University Hospital, Republic of Ireland. METHOD: A quantitative descriptive design was used in the study. A questionnaire developed by ENA was distributed to emergency nurses working in a level I trauma emergency department at Cork University Hospital. The total sample number was 90, including all emergency nurses with at least 6 months\\' emergency nursing experience. RESULTS: Emergency nurses often took families to the bedside during resuscitation efforts (58.9%) or would do so if the opportunity arose (17.8%). A high percentage (74.4%) of respondents would prefer a written policy allowing the option of family presence during CPR. The most significant barrier to family witnessed resuscitation (FWR) was conflicts occurring within the emergency team. The most significant facilitator to FWR was a greater understanding of health care professionals on the benefits of FWR to patients and families, indicating the need for educational development. CONCLUSION: The findings of the study and previously published studies indicate the need for development of written polices and guidelines on the practice to meet the needs of patients, families, and staff by providing consistent, safe, and caring practices for all involved in the resuscitation process. Recommendations of the study include the development of a written policy and an educational programme on the safe implementation and practices of FWR.

  9. Preliminary assessment of a combined passive safety system for typical 3-loop PWR CPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zijiang; Shan, Jianqiang, E-mail: jqshan@mail.xjtu.edu.cn; Gou, Junli

    2017-03-15

    Highlights: • A combined passive safety system was placed on a typical 3-loop PWR CPR1000. • Three accident analyses show the three different accident mitigation methods of the passive safety system. • The three mitigation methods were proved to be useful. - Abstract: As the development of the nuclear industry, passive technology turns out to be a remarkable characteristic of advanced nuclear power plants. Since the 20th century, much effort has been given to the passive technology, and a number of evolutionary passive systems have developed. Thoughts have been given to upgrade the existing reactors with passive systems to meet stricter safety demands. In this paper, the CPR1000 plant, which is one kind of mature pressurized water reactor plants in China, is improved with some passive systems to enhance safety. The passive systems selected are as follows: (1) the reactor makeup tank (RMT); (2) the advanced accumulator (A-ACC); (3) the in-containment refueling water storage tank (IRWST); (4) the passive emergency feed water system (PEFS), which is installed on the secondary side of SGs; (5) the passive depressurization system (PDS). Although these passive components is based on the passive technology of some advanced reactors, their structural and trip designs are adjusted specifically so that it could be able to mitigate accidents of the CPR1000. Utilizing the RELAP5/MOD3.3 code, accident analyses (small break loss of coolant accident, large break loss of coolant accident, main feed water line break accident) of this improved CPR1000 plant were presented to demonstrate three different accident mitigation methods of the safety system and to test whether the passive safety system preformed its function well. In the SBLOCA, all components of the passive safety system were put into work sequentially, which prevented the core uncover. The LBLOCA analysis illustrates the contribution of the A-ACCs whose small-flow-rate injection can control the maximum cladding

  10. Classroom versus Computer-Based CPR Training: A Comparison of the Effectiveness of Two Instructional Methods

    Science.gov (United States)

    Rehberg, Robb S.; Gazzillo Diaz, Linda; Middlemas, David A.

    2009-01-01

    Objective: The objective of this study was to determine whether computer-based CPR training is comparable to traditional classroom training. Design and Setting: This study was quantitative in design. Data was gathered from a standardized examination and skill performance evaluation which yielded numerical scores. Subjects: The subjects were 64…

  11. Long-term retrospective analysis of mackerel spawning in the North Sea: a new time series and modeling approach to CPR data.

    Science.gov (United States)

    Jansen, Teunis; Kristensen, Kasper; Payne, Mark; Edwards, Martin; Schrum, Corinna; Pitois, Sophie

    2012-01-01

    We present a unique view of mackerel (Scomber scombrus) in the North Sea based on a new time series of larvae caught by the Continuous Plankton Recorder (CPR) survey from 1948-2005, covering the period both before and after the collapse of the North Sea stock. Hydrographic backtrack modelling suggested that the effect of advection is very limited between spawning and larvae capture in the CPR survey. Using a statistical technique not previously applied to CPR data, we then generated a larval index that accounts for both catchability as well as spatial and temporal autocorrelation. The resulting time series documents the significant decrease of spawning from before 1970 to recent depleted levels. Spatial distributions of the larvae, and thus the spawning area, showed a shift from early to recent decades, suggesting that the central North Sea is no longer as important as the areas further west and south. These results provide a consistent and unique perspective on the dynamics of mackerel in this region and can potentially resolve many of the unresolved questions about this stock.

  12. Long-term retrospective analysis of mackerel spawning in the North Sea: a new time series and modeling approach to CPR data.

    Directory of Open Access Journals (Sweden)

    Teunis Jansen

    Full Text Available We present a unique view of mackerel (Scomber scombrus in the North Sea based on a new time series of larvae caught by the Continuous Plankton Recorder (CPR survey from 1948-2005, covering the period both before and after the collapse of the North Sea stock. Hydrographic backtrack modelling suggested that the effect of advection is very limited between spawning and larvae capture in the CPR survey. Using a statistical technique not previously applied to CPR data, we then generated a larval index that accounts for both catchability as well as spatial and temporal autocorrelation. The resulting time series documents the significant decrease of spawning from before 1970 to recent depleted levels. Spatial distributions of the larvae, and thus the spawning area, showed a shift from early to recent decades, suggesting that the central North Sea is no longer as important as the areas further west and south. These results provide a consistent and unique perspective on the dynamics of mackerel in this region and can potentially resolve many of the unresolved questions about this stock.

  13. System for measuring the proton polarization in a polarized target

    International Nuclear Information System (INIS)

    Karnaukhov, I.M.; Lukhanin, A.A.; Telegin, Yu.N.; Trotsenko, V.I.; Chechetenko, V.F.

    1984-01-01

    The system for measuring the proton polarization in a polarized target representing the high-sensitivity nuclear magnetic resonance (NMR) is described Q-meter with series connection and a circuit for measuring system resonance characteristic is used for NMR-absorption signal recording. Measuring coil is produced of a strip conductor in order to obtain uniform system sensitivity to polarization state in all target volume and improve signal-to-noise ratio. Polarization measuring system operates ion-line with the M-6000 computer. The total measuring error for the value of free proton polarization in target taking into account the error caused by local depolarization of working substance under irradiation by high-intense photon beam is <= 6%. Long-term application of the described system for measuring the proton polarization in the LUEh-20000 accelerator target used in the pion photoproduction experiments has demonstrated its high reliability

  14. A Note on the Radiative and Collisional Branching Ratios in Polarized Radiation Transport with Coherent Scattering

    Science.gov (United States)

    Casini, R.; del Pino Alemán, T.; Manso Sainz, R.

    2017-02-01

    We discuss the implementation of physically meaningful branching ratios between the CRD and partial redistribution contributions to the emissivity of a polarized multi-term atom in the presence of both inelastic and elastic collisions. Our derivation is based on a recent theoretical formulation of partially coherent scattering, and it relies on a heuristic diagrammatic analysis of the various radiative and collisional processes to determine the proper form of the branching ratios. The expression we obtain for the emissivity is {\\boldsymbol{\\varepsilon }}=[{{\\boldsymbol{\\varepsilon }}}(1)-{{\\boldsymbol{\\varepsilon }}}{{f}.{{s}}.}(2)]+{{\\boldsymbol{\\varepsilon }}}(2), where {{\\boldsymbol{\\varepsilon }}}(1) and {{\\boldsymbol{\\varepsilon }}}(2) are the emissivity terms for the redistributed and partially coherent radiation, respectively, and where “f.s.” implies that the corresponding term must be evaluated assuming a flat-spectrum average of the incident radiation. This result is shown to be in agreement with prior literature on the subject in the limit of the unpolarized multi-level atom.

  15. Emergency Victim Care. A Training Manual for Emergency Medical Technicians. Module 5. CPR, Oxygen Therapy. Revised.

    Science.gov (United States)

    Ohio State Dept. of Education, Columbus. Div. of Vocational Education.

    This student manual, the fifth in a set of 14 modules, is designed to train emergency medical technicians (EMTs) in Ohio. The module contains two sections covering the following course content; cardiopulmonary resuscitation (CPR) (including artificial ventilation, foreign body obstructions, adjunctive equipment and special techniques, artificial…

  16. Expression, purification, crystallization and preliminary X-ray analysis of conjugated polyketone reductase C2 (CPR-C2) from Candida parapsilosis IFO 0708

    International Nuclear Information System (INIS)

    Yamamura, Akihiro; Maruoka, Shintaro; Ohtsuka, Jun; Miyakawa, Takuya; Nagata, Koji; Kataoka, Michihiko; Kitamura, Nahoko; Shimizu, Sakayu; Tanokura, Masaru

    2009-01-01

    Conjugated polyketone reductase C2 from C. parapsilosis IFO 0708 was expressed, purified and crystallized by the sitting-drop vapour-diffusion method. The crystal belonged to space group P2 1 2 1 2 1 and diffracted X-rays to 1.7 Å resolution. Conjugated polyketone reductase C2 (CPR-C2) from Candida parapsilosis IFO 0708 is a member of the NADPH-dependent aldo-keto reductase (AKR) superfamily and catalyzes the stereospecific reduction of ketopantoyl lactone to d-pantoyl lactone. A diffraction-quality crystal of recombinant CPR-C2 was obtained by the sitting-drop vapour-diffusion method using PEG 3350 as the precipitant. The crystal diffracted X-rays to 1.7 Å resolution on beamline NW12A of the Photon Factory-Advanced Ring (Tsukuba, Japan). The crystal belonged to space group P2 1 2 1 2 1 , with unit-cell parameters a = 55.02, b = 68.30, c = 68.93 Å. The Matthews coefficient (V M = 1.76 Å 3 Da −1 ) indicated that the crystal contained one CPR-C2 molecule per asymmetric unit

  17. [11C]PR04.MZ, a promising DAT ligand for low concentration imaging: synthesis, efficient 11C-O-methylation and initial small animal PET studies

    International Nuclear Information System (INIS)

    Riss, P.J.; Hooker, J.; Alexoff, D.; Kim, Sung-Won; Fowler, J.S.; Roesch, F.

    2009-01-01

    PR04.MZ was designed as a highly selective dopamine transporter inhibitor, derived from natural cocaine. Its binding profile indicates that [ 11 C]PR04.MZ may be suited as a PET radioligand for the non-invasive exploration of striatal and extrastriatal DAT populations. As a key feature, its structural design facilitates both, labelling with fluorine-18 at its terminally fluorinated butynyl moiety and carbon-11 at its methyl ester function. The present report concerns the efficient [ 11 C]MeI mediated synthesis of [ 11 C]PR04.MZ from an O-desmethyl precursor trifluoroacetic acid salt with Rb 2 CO 3 in DMF in up to 95 ± 5% labelling yield. A preliminary μPET-experiment demonstrates the reversible, highly specific binding of [ 11 C]PR04.MZ in the brain of a male Sprague-Dawley rat.

  18. Scattering with polarized neutrons

    International Nuclear Information System (INIS)

    Schweizer, J.

    2007-01-01

    In the history of neutron scattering, it was shown very soon that the use of polarized neutron beams brings much more information than usual scattering with unpolarized neutrons. We shall develop here the different scattering methods that imply polarized neutrons: 1) polarized beams without polarization analysis, the flipping ratio method; 2) polarized beams with a uniaxial polarization analysis; 3) polarized beams with a spherical polarization analysis. For all these scattering methods, we shall give examples of the physical problems which can been solved by these methods, particularly in the field of magnetism: investigation of complex magnetic structures, investigation of spin or magnetization densities in metals, insulators and molecular compounds, separation of magnetic and nuclear scattering, investigation of magnetic properties of liquids and amorphous materials and even, for non magnetic material, separation between coherent and incoherent scattering. (author)

  19. A comparison between the two methods of chest compression in infant and neonatal resuscitation. A review according to 2010 CPR guidelines.

    Science.gov (United States)

    Douvanas, Alexandros; Koulouglioti, Christina; Kalafati, Maria

    2018-03-01

    The quality of chest compression (CC) delivered during neonatal and infant cardiopulmonary resuscitation (CPR) is identified as the most important factor to achieve the increase of survival rate without major neurological deficit to the patients. The objective of the study was to systematically review all the available studies that have compared the two different techniques of hand placement on infants and neonatal resuscitation, from 2010 to 2015 and to highlight which method is more effective. A review of the literature using a variety of medical databases, including Cochrane, MEDLINE, and SCOPUS electronic databases. The following MeSH terms were used in the search: infant, neonatal, CPR, CC, two-thumb (TT) technique/method, two-finger (TF) technique/method, rescuer fatigue, thumb/finger position/placement, as well as combinations of these. Ten studies met the inclusion criteria; nine observational studies and a randomized controlled trial. All providers performed either continuous TF or TT technique CCs and the majority of CPR performance was taken place in infant trainer manikin. The majority of the studies suggest the TT method as the more useful for infants and neonatal resuscitation than the TF.

  20. XPS study of Li/Nb ratio in LiNbO{sub 3} crystals. Effect of polarity and mechanical processing on LiNbO{sub 3} surface chemical composition

    Energy Technology Data Exchange (ETDEWEB)

    Skryleva, E.A., E-mail: easkryleva@gmail.com; Kubasov, I.V., E-mail: kubasov.ilya@gmail.com; Kiryukhantsev-Korneev, Ph.V., E-mail: kiruhancev-korneev@yandex.ru; Senatulin, B.R., E-mail: borisrs@yandex.ru; Zhukov, R.N., E-mail: rom_zhuk@mail.ru; Zakutailov, K.V., E-mail: zakkonst@gmail.com; Malinkovich, M.D., E-mail: malinkovich@yandex.ru; Parkhomenko, Yu.N., E-mail: parkh@rambler.ru

    2016-12-15

    Highlights: • XPS Li/Nb ratio measurement uncertainty in LNbO3 specimens was obtained. • The effect of polarization on surface chemistry was observed only on cleaves. • Li/Nb ratio on positive cleave surface is higher than on negative one. • The positive cleave surface adsorbs fluorine more efficiently than negative one. • Mechanical processing of crystals reduces surface Li/Nb. - Abstract: Different sections of congruent lithium niobate (CLN) crystals have been studied using X-ray photoelectron spectroscopy (XPS). We have developed a method for measuring the lithium-to-niobium atomic ratio Li/Nb from the ratio of the Li1s and Nb4s spectral integral intensities with an overall error of within 8 %. Polarity and mechanical processing affect the Li/Nb ratio on CLN crystal surfaces. The Li/Nb ratio is within the tolerance (0.946 ± 0.074) on the negative cleave surface Z, and there is excess lithium (Li/Nb = 1.25 ± 0.10) on the positive surface. The positive surfaces of the 128° Y cut plates after long exposure to air exhibit LiOH formation indications (obvious lithium excess, higher Li1s spectral binding energy and a wide additional peak in the O1s spectrum produced by nonstructural oxygen). XPS and glow discharge optical electron spectroscopy showed that mechanical processing of differently oriented crystals (X, Z and 128° Y) and different polarities dramatically reduces the Li/Nb ratio. In situ fluorine adsorption experiments revealed the following regularities: fluorine adsorption only occurred on crystal cleaves and was not observed for mechanically processed specimens. Positive cleave surfaces have substantially higher fluorine adsorption capacity compared to negative ones.

  1. Training and Confidence Level of Junior Anaesthetists in CPR- Experience in A Developing Country

    OpenAIRE

    Desalu Ibironke; O Oyedepo Olanrewaju; J Olatosi Olutola

    2008-01-01

    Training in resuscitation is done worldwide by a dedicated council who is responsible for training and frequent recertification. Nigeria has no Resuscitation council and training is the responsibility of individual health institutions. There is no mandatory law on resuscitation training or recertification. This study sought to investigate how much training in CPR occurs, how effective this training is and how confident our anaesthetic trainees are in implementing present guidelines. A deta...

  2. Electron-Spin Filters Would Offer Spin Polarization Greater than 1

    Science.gov (United States)

    Ting, David Z.

    2009-01-01

    A proposal has been made to develop devices that would generate spin-polarized electron currents characterized by polarization ratios having magnitudes in excess of 1. Heretofore, such devices (denoted, variously, as spin injectors, spin polarizers, and spin filters) have typically offered polarization ratios having magnitudes in the approximate range of 0.01 to 0.1. The proposed devices could be useful as efficient sources of spin-polarized electron currents for research on spintronics and development of practical spintronic devices.

  3. A Comparison of Internet-Based Learning and Traditional Classroom Lecture to Learn CPR for Continuing Medical Education

    Science.gov (United States)

    Hemmati, Nima; Omrani, Soghra; Hemmati, Naser

    2013-01-01

    The purpose of this study was to compare the satisfaction and effectiveness of Internet-based learning (IBL) and traditional classroom lecture (TCL) for continuing medical education (CME) programs by comparing final resuscitation exam results of physicians who received the newest cardiopulmonary resuscitation (CPR) curriculum guidelines training…

  4. Ratios of regioisomers of minor acylglycerols less polar than triricinolein in castor oil estimated by mass spectrometry and the biosynthesis of tetraacylglycerols in castor

    Science.gov (United States)

    We have recently reported the identification of forty new minor molecular species of acylglycerols containing hydroxy fatty acids less polar than triricinolein by electrospray ionization mass spectrometry of the lithium adducts. The ratios of regioisomers of triacylglycerols (ABC and AAB types) and ...

  5. Design and simulation of a novel circularly polarized antenna with polarization reconfigurable characteristics

    Directory of Open Access Journals (Sweden)

    Zhang Hai

    2016-01-01

    Full Text Available A novel circularly polarized antenna with polarization reconfigurable characteristics was designed using co-simulation of Ansoft HFSS and Designer software. It consists of a dual-polarized antenna and phase switching network which act as the feed network for the dual-polarized antenna. The phase switching network was designed based on a Wilkinson power divider, where the output port was connected with SPDT to form a switching network. By controlling the SPDT state-off / on, the phase difference of the two ports could be alternated, which generated the orthogonal modes between the two ports of dual-polarized antenna. So that Left-hand circular polarization (LHCP and Right-hand circular polarization (RHCP could be achieved. The simulation shown that reflection coefficient was less than -12 dB and the axial ratio was below 3 dB between 1.8 GHz and 2.4 GHz with polarization reconfigurable characteristics.

  6. Keep pushing! Limiting interruptions to CPR; bag-valve mask versus i-gel® airway ventilation

    Directory of Open Access Journals (Sweden)

    Craig Vincent-Lambert

    2016-12-01

    Conclusion: The use of the i-gel® airway resulted in a considerable decrease in the amount of time spent on ventilations and in more compressions being performed. The overall reduction in HOT was, however, offset by the time it took to secure the device. Further investigation into the use and securing of the i-gel® airway in single rescuer CPR is recommended.

  7. Qualified measurement setup of polarization extinction ratio for Panda PMF with LC/UPC connector

    Science.gov (United States)

    Thongdaeng, Rutsuda; Worasucheep, Duang-rudee; Ngiwprom, Adisak

    2018-03-01

    Polarization Extinction Ratio (PER) is one of the key parameters for Polarization Maintaining Fiber (PMF) connector. Based on our previous studies, the bending radius of fiber greater than 1.5 cm will not affect the insertion loss of PMF [1]. Moreover, the measured PER of Panda PMF with LC/UPC connectors is more stable when that PMF is coiled around a hot rod with a minimum of 3-cm in diameter at 75°C temperature [2]. Hence, the hot rod with less constrained 6-cm in diameter at constant 75°C was selected for this PER measurement. Two PER setups were verified and compared for measuring LC/UPC PMF connectors. The Polarized Laser Source (PLS) at 1550 nm wavelength and PER meter from OZ Optics were used in both setups, in which the measured connector was connected to PLS at 0° angle while the other end was connected to PER meter. In order to qualify our setups, the percentage of Repeatability and Reproducibility (%R&R) were tested and calculated. In each setup, the PER measurement was repeated 3 trials by 3 appraisers using 10 LC/UPC PMF connectors (5 LC/UPC PMF patchcords with 3.5+/-0.5 meters in length) in random order. The 1st setup, PMF was coiled at a larger 20-cm diameter for 3 to 5 loops and left in room temperature during the test. The 2nd setup, PMF was coiled around a hot rod at constant 75°C with 6-cm diameter for 8 to 10 loops for at least 5 minutes before testing. There are 3 ranges of %R&R acceptation guide line: <10% is acceptable, between 10% - 30% is marginal, and <30% is unacceptable. According to our results, the %R&R of the 1st PER test setup was 16.2% as marginality, and the 2nd PER test setup was 8.9% as acceptance. Thus, providing the better repeatability and reproducibility, this 2nd PER test setup having PMF coiled around a hot rod at constant 75°C with 6-cm diameter was selected for our next study of the impact of hot temperature on PER in LC/UPC PMF connector.

  8. New experimental possibility to search for the ratio of a possible T-violating amplitude to the weak-interaction amplitude in polarized neutron transmission through a polarized nuclear target

    CERN Document Server

    Lukashevich, V V; Dallman, David

    2011-01-01

    This paper considers a spin-dependent neutron interaction with optical potentials (fields) from the strong interaction, the weak interaction, and an assumed T-violating interaction. The vector sum of these fields and their interferences determines an effective field of the target with an angular position in space due to polar and azimuthal angles. The phase of the azimuthal component is found to be the sum of two angles. The tangent of the first angle is equal to the ratio of the T-violating forward-scattering amplitude D to the weak-interaction amplitude C. The quantity is of interest. The tangent of the second angle depends on the spin rotation in the residual pseudomagnetic field of the target, and it can be treated as a background effect. This paper shows that the second angle has different signs in measurements with polarized and unpolarized neutrons; thus, two measurements allow it to be compensated for. In addition, the use of the Ramsey method of separated oscillatory fields for measurement of the neu...

  9. Outcome of cardiopulmonary resuscitation - predictors of survival

    International Nuclear Information System (INIS)

    Ishtiaq, O.; Iqbal, M.; Zubair, M.; Qayyum, R.; Adil, M.

    2008-01-01

    To assess the outcomes of patients undergoing cardiopulmonary resuscitation (CPR). Data were collected retrospectively of all adult patients who underwent CPR. Clinical outcomes of interest were survival at the end of CPR and survival at discharge from hospital. Factors associated with survival were evaluated using logistic regression analysis. Of the 159 patients included, 55 (35%) were alive at the end of CPR and 17 (11%) were discharged alive from the hospital. At the end of CPR, univariate logistic regression analysis found the following factors associated with survival: cardiac arrest within hospital as compared to outside the hospital (odds ratio = 2.8, 95% CI = 1.27-6.20, p-value = 0.01), both cardiac and pulmonary arrest as compared to either cardiac or pulmonary arrest (odds ratio = 0.37, 95% CI = 0.19- 0.73, p-value = 0.004), asystole as cardiac rhythm at presentation (odds ratio = 0.47, 95% CI = 0.24-0.93, p-value = 0.03), and total atropine dose given during CPR (odds ratio = 0.78, 95% CI = 0.62-0.97, p-value = 0.02). In multivariate logistic regression, cardiac arrest within hospital (odds ratio = 2.52, 95% CI = 1.06-5.99, p-value = 0.04) and both cardiac and pulmonary arrest as compared to cardiac or pulmonary arrest (odds ratio = 0.44, 95% CI = 0.21-0.91, p-value = 0.03) were associated with survival at the end of CPR. At the time of discharge from hospital, univariate logistic regression analysis found following factors that were associated with survival: cardiac arrest within hospital (odds ratio = 8.4, 95% CI = 1.09-65.64, p-value = 0.04), duration of CPR (odds ratio = 0.91, 95% CI = 0.85-0.96, p-value = 0.001), and total atropine dose given during CPR (odds ratio = 0.68, 95% CI = 0.47-0.99, p-value = 0.05). In multivariate logistic regression analysis cardiac arrest within hospital (odds ratio 8.69, 95% CI = 1.01-74.6, p-value = 0.05) and duration of CPR (odds ratio 0.92, 95% CI = 0.87-0.98, p-value = 0.01) were associated with survival at

  10. Design and transient analyses of passive emergency feedwater system of CPR1000. Part 1. Air cooling condition

    International Nuclear Information System (INIS)

    Zhang Yapei; Qiu Suizheng; Su Guanghui; Tian Wenxi; Cao Jianhua; Lu Donghua; Fu Xiangang

    2011-01-01

    The steam generator secondary passive emergency feedwater system is a new design for traditional generation Ⅱ + reactor CPR1000. The passive emergency feedwater system is designed to supply water to the SG shell side and improve the safety and reliability of CPR1000 by completely or partially replacing traditional emergency water cooling system in the event of the feed line break (FLB) or loss of heat sink accident. The passive emergency feedwater system consists of steam generator (SG), heat exchanger (HX), air cooling tower, emergency makeup tank (EMT), and corresponding pipes and valves for air cooling condition. In order to improve the safety and reliability of CPR1000, the model of the primary loop system and the passive emergency feedwater system was developed to investigate residual heat removal capability of the passive emergency feedwater system and the transient characteristics of the primary loop system affected by the passive emergency feedwater system using RELAP5/MOD3.4. The transient characteristics of the primary loop system and the passive emergency feedwater system were calculated in the event of feed line break accident. Sensitivity studies of the passive emergency feedwater system were also conducted to investigate the response of the primary loop and the passive emergency feedwater system on the main parameters of the passive emergency feedwater system. The passive emergency feedwater system could supply water to the SG shell side from the EMT successfully. The calculation results showed that the passive emergency feedwater system could take away the decay heat from the primary loop effectively for air cooling condition, and that the single-phase and two-phase natural circulations were established in the primary loop and passive emergency feedwater system loop, respectively. (author)

  11. The addition of voice prompts to audiovisual feedback and debriefing does not modify CPR quality or outcomes in out of hospital cardiac arrest--a prospective, randomized trial.

    Science.gov (United States)

    Bohn, Andreas; Weber, Thomas P; Wecker, Sascha; Harding, Ulf; Osada, Nani; Van Aken, Hugo; Lukas, Roman P

    2011-03-01

    Chest compression quality is a determinant of survival from out-of-hospital cardiac arrest (OHCA). ERC 2005 guidelines recommend the use of technical devices to support rescuers giving compressions. This prospective randomized study reviewed influence of different feedback configurations on survival and compression quality. 312 patients suffering an OHCA were randomly allocated to two different feedback configurations. In the limited feedback group a metronome and visual feedback was used. In the extended feedback group voice prompts were added. A training program was completed prior to implementation, performance debriefing was conducted throughout the study. Survival did not differ between the extended and limited feedback groups (47.8% vs 43.9%, p = 0.49). Average compression depth (mean ± SD: 4.74 ± 0.86 cm vs 4.84 ± 0.93 cm, p = 0.31) was similar in both groups. There were no differences in compression rate (103 ± 7 vs 102 ± 5 min(-1), p=0.74) or hands-off fraction (16.16% ± 0.07 to 17.04% ± 0.07, p = 0.38). Bystander CPR, public arrest location, presenting rhythm and chest compression depth were predictors of short term survival (ROSC to ED). Even limited CPR-feedback combined with training and ongoing debriefing leads to high chest compression quality. Bystander CPR, location, rhythm and chest compression depth are determinants of survival from out of hospital cardiac arrest. Addition of voice prompts does neither modify CPR quality nor outcome in OHCA. CC depth significantly influences survival and therefore more focus should be put on correct delivery. Further studies are needed to examine the best configuration of feedback to improve CPR quality and survival. ClinicalTrials.gov (NCT00449969), http://www.clinicalTrials.gov. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Mobile phone technology identifies and recruits trained citizens to perform CPR on out-of-hospital cardiac arrest victims prior to ambulance arrival.

    Science.gov (United States)

    Ringh, Mattias; Fredman, David; Nordberg, Per; Stark, Tomas; Hollenberg, Jacob

    2011-12-01

    In a two-parted study, evaluate a new concept were mobile phone technology is used to dispatch lay responders to nearby out-of-hospital cardiac arrests (OHCAs). Mobile phone positioning systems (MPS) can geographically locate selected mobile phone users at any given moment. A mobile phone service using MPS was developed and named Mobile Life Saver (MLS). Simulation study: 25 volunteers named mobile responders (MRs) were connected to MLS. Ambulance time intervals from 22 consecutive OHCAs in 2005 were used as controls. The MRs randomly moved in Stockholm city centre and were dispatched to simulated OHCAs (identical to controls) if they were within a 350 m distance. Real life study: during 25 weeks 1271-1801 MRs trained in CPR were connected to MLS. MLS was activated at the dispatch centre in parallel with ambulance dispatch when an OHCA was suspected. The MRs were dispatched if they were within 500 m from the suspected OHCA. Simulation study: mean response time for the MRs compared to historical ambulance time intervals was reduced by 2 min 20s (44%), pMobile phone technology can be used to identify and recruit nearby CPR-trained citizens to OHCAs for bystander CPR prior to ambulance arrival. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. A Si nanocube array polarizer

    Science.gov (United States)

    Chen, Linghua; Jiang, Yingjie; Xing, Li; Yao, Jun

    2017-10-01

    We have proposed a full dielectric (silicon) nanocube array polarizer based on a silicon dioxide substrate. Each polarization unit column includes a plurality of equal spaced polarization units. By optimizing the length, the width, the height of the polarization units and the center distance of adjacent polarization unit (x direction and y direction), an extinction ratio (ER) of higher than 25dB was obtained theoretically when the incident light wavelength is 1550nm. while for applications of most polarization optical elements, ER above 10dB is enough. With this condition, the polarizer we designed can work in a wide wavelength range from 1509.31nm to 1611.51nm. Compared with the previous polarizer, we have introduced a polarizer which is a full dielectric device, which solves the problems of low efficiency caused by Ohmic loss and weak coupling. Furthermore, compared with the existing optical polarizers, our polarizer has the advantages of thin thickness, small size, light weight, and low processing difficulty, which is in line with the future development trend of optical elements.

  14. Measuring fluorescence polarization with a dichrometer.

    Science.gov (United States)

    Sutherland, John C

    2017-09-01

    A method for obtaining fluorescence polarization data from an instrument designed to measure circular and linear dichroism is compared with a previously reported approach. The new method places a polarizer between the sample and a detector mounted perpendicular to the direction of the incident beam and results in determination of the fluorescence polarization ratio, whereas the previous method does not use a polarizer and yields the fluorescence anisotropy. A similar analysis with the detector located axially with the excitation beam demonstrates that there is no frequency modulated signal due to fluorescence polarization in the absence of a polarizer. Copyright © 2017. Published by Elsevier Inc.

  15. Single photon detector with high polarization sensitivity.

    Science.gov (United States)

    Guo, Qi; Li, Hao; You, LiXing; Zhang, WeiJun; Zhang, Lu; Wang, Zhen; Xie, XiaoMing; Qi, Ming

    2015-04-15

    Polarization is one of the key parameters of light. Most optical detectors are intensity detectors that are insensitive to the polarization of light. A superconducting nanowire single photon detector (SNSPD) is naturally sensitive to polarization due to its nanowire structure. Previous studies focused on producing a polarization-insensitive SNSPD. In this study, by adjusting the width and pitch of the nanowire, we systematically investigate the preparation of an SNSPD with high polarization sensitivity. Subsequently, an SNSPD with a system detection efficiency of 12% and a polarization extinction ratio of 22 was successfully prepared.

  16. Degree of polarization and source counts of faint radio sources from Stacking Polarized intensity

    International Nuclear Information System (INIS)

    Stil, J. M.; George, S. J.; Keller, B. W.; Taylor, A. R.

    2014-01-01

    We present stacking polarized intensity as a means to study the polarization of sources that are too faint to be detected individually in surveys of polarized radio sources. Stacking offers not only high sensitivity to the median signal of a class of radio sources, but also avoids a detection threshold in polarized intensity, and therefore an arbitrary exclusion of sources with a low percentage of polarization. Correction for polarization bias is done through a Monte Carlo analysis and tested on a simulated survey. We show that the nonlinear relation between the real polarized signal and the detected signal requires knowledge of the shape of the distribution of fractional polarization, which we constrain using the ratio of the upper quartile to the lower quartile of the distribution of stacked polarized intensities. Stacking polarized intensity for NRAO VLA Sky Survey (NVSS) sources down to the detection limit in Stokes I, we find a gradual increase in median fractional polarization that is consistent with a trend that was noticed before for bright NVSS sources, but is much more gradual than found by previous deep surveys of radio polarization. Consequently, the polarized radio source counts derived from our stacking experiment predict fewer polarized radio sources for future surveys with the Square Kilometre Array and its pathfinders.

  17. Research on Full-polarization Bistatic Scattering Characteristics of Aircraft

    Directory of Open Access Journals (Sweden)

    Ai Xiaofeng

    2016-12-01

    Full Text Available Whole space polarimetric bistatic scattering data of full-size aircraft targets were calculated via the mature electromagnetic calculation software. The fluctuation statistics characteristic of the polarimetric bistatic Radar Cross-Section (RCS was carried out. It was found that the statistical properties of the four polarimetric types (HH, HV, VH, VV of polarimetric bistatic RCSs are nearly the same, while the monostatic main and cross polarization RCSs statistical properties were quite different from each other. The characteristics of the distribution statistic for the monostatic and bistatic polarization ratio were carried out. Moreover, it was found that the cross-main polarization ratios were quite different, while the main polarization ratios were similar. The statistical results provide a theoretical reference for fully polarimetric bistatic radar aircraft target detection experiments.

  18. A Polarization Maintaining Filter based on a Liquid-Crystal-Photonic-Bandgap-Fiber

    DEFF Research Database (Denmark)

    Scolari, Lara; Olausson, Christina Bjarnal Thulin; Turchinovich, Dmitry

    2008-01-01

    A polarization maintaining filter based on a liquid-crystal-photonic-bandgap-fiber is demonstrated. Its polarization extinction ratio is 14 dB at 1550 nm. Its tunability is 150 nm.......A polarization maintaining filter based on a liquid-crystal-photonic-bandgap-fiber is demonstrated. Its polarization extinction ratio is 14 dB at 1550 nm. Its tunability is 150 nm....

  19. Compact electrically controlled broadband liquid crystal photonic bandgap fiber polarizer

    DEFF Research Database (Denmark)

    Wei, Lei; Alkeskjold, Thomas Tanggaard; Bjarklev, Anders Overgaard

    2009-01-01

    An electrically controlled liquid crystal photonic-bandgap fiber polarizer is experimentally demonstrated. A maximum 21.3dB electrically tunable polarization extinction ratio is achieved with 45° rotatable transmission axis as well as switched on and off in 1300nm–1600nm.......An electrically controlled liquid crystal photonic-bandgap fiber polarizer is experimentally demonstrated. A maximum 21.3dB electrically tunable polarization extinction ratio is achieved with 45° rotatable transmission axis as well as switched on and off in 1300nm–1600nm....

  20. Updated teaching techniques improve CPR performance measures: a cluster randomized, controlled trial.

    Science.gov (United States)

    Ettl, Florian; Testori, Christoph; Weiser, Christoph; Fleischhackl, Sabine; Mayer-Stickler, Monika; Herkner, Harald; Schreiber, Wolfgang; Fleischhackl, Roman

    2011-06-01

    The first-aid training necessary for obtaining a drivers license in Austria has a regulated and predefined curriculum but has been targeted for the implementation of a new course structure with less theoretical input, repetitive training in cardiopulmonary resuscitation (CPR) and structured presentations using innovative media. The standard and a new course design were compared with a prospective, participant- and observer-blinded, cluster-randomized controlled study. Six months after the initial training, we evaluated the confidence of the 66 participants in their skills, CPR effectiveness parameters and correctness of their actions. The median self-confidence was significantly higher in the interventional group [IG, visual analogue scale (VAS:"0" not-confident at all,"100" highly confident):57] than in the control group (CG, VAS:41). The mean chest compression rate in the IG (98/min) was closer to the recommended 100 bpm than in the CG (110/min). The time to the first chest compression (IG:25s, CG:36s) and time to first defibrillator shock (IG:86s, CG:92s) were significantly shorter in the IG. Furthermore, the IG participants were safer in their handling of the defibrillator and started with countermeasures against developing shock more often. The management of an unconscious person and of heavy bleeding did not show a difference between the two groups even after shortening the lecture time. Motivation and self-confidence as well as skill retention after six months were shown to be dependent on the teaching methods and the time for practical training. Courses may be reorganized and content rescheduled, even within predefined curricula, to improve course outcomes. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Terahertz wave polarization beam splitter using a cascaded multimode interference structure.

    Science.gov (United States)

    Li, Jiu-sheng; Liu, Han; Zhang, Le

    2014-08-01

    A terahertz wave polarization beam splitter, based on two cascaded multimode interference structures with different widths, is designed and numerically demonstrated. The numerical calculation results show that the designed polarization beam splitter can split transverse-electric (TE) and transverse-magnetic (TM)-polarized terahertz waves into different propagation directions with high efficiency over a frequency range from 6.40 to 6.50 THz. This polarization beam splitter shows more than a 22.06 dB extinction ratio for TE-polarization and a 31.65 dB extinction ratio for TM-polarization. Using such a polarization beam splitter, the whole length of the polarization beam splitter is reduced to about 1/12 that of a conventional design. This enables the polarization beam splitter to be used in terahertz wave integrated circuit fields.

  2. Analysis of CMOS Compatible Cu-Based TM-Pass Optical Polarizer

    KAUST Repository

    Ng, Tien Khee; Khan, Mohammed Zahed Mustafa; Al-Jabr, Ahmad Ali; Ooi, Boon S.

    2012-01-01

    for the polarizer, it was found that the metal-insulator-metal (MIM) polarizer structure is superior compared to the insulator-metal-insulator polarizer structure due to its higher polarization extinction ratio (PER) and low insertion loss. An optimized MIM TM

  3. Design optimization on structure of blowdown in CPR1000 steam generator

    International Nuclear Information System (INIS)

    Wang Guoxian; Ren Hongbing; Zuo Chaoping; Zhu Yong; Mo Shaojia

    2014-01-01

    The structure of blowdown in CPR1000 steam generator has been optimized by eliminating the blowdown pipe and tube lane blocking, drilling holes in the peripheral tube lane, which can improve the accessibility of the central tube lane and facilitate inspecting and lancing. This paper detailed compares and analyzes the thermal hydraulic characteristic before and after optimization using GENEPI code which a special software for SG thermal hydraulic analysis. The results showed that the thermal hydraulic characteristic of steam generator meets the design requirements compared with the original design. Structure optimization can improve lancing effects, although the change of flow field distribution above the tubesheet leads to increase the number of tube subjected to sludge deposit. The analysis results proved the feasibility of the optimization. (authors)

  4. Arabidopsis CPR5 is a senescence-regulatory gene with pleiotropic functions as predicted by the evolutionary theory of senescence

    NARCIS (Netherlands)

    Jing, Hai-Chun; Anderson, Lisa; Sturre, Marcel J. G.; Hille, Jacques; Dijkwel, Paul P.

    2007-01-01

    Arabidopsis CPR5 is a senescence-regulatory gene with pleiotropic functions as predicted by the evolutionary theory of senescence Hai-Chun Jing1,2, Lisa Anderson3, Marcel J.G. Sturre1, Jacques Hille1 and Paul P. Dijkwel1,* 1Molecular Biology of Plants, Groningen Biomolecular Sciences and

  5. TM-pass polarizer based on multilayer graphene polymer waveguide

    Science.gov (United States)

    Cai, Ke-su; Li, Yue-e.; Wei, Wen-jing; Mu, Xi-jiao; Ma, A.-ning; Wang, Zhong; Song, Dan-ming

    2018-05-01

    A TM-pass polarizer based on multilayer graphene polymer waveguide is proposed and theoretically analyzed. The mode properties, the extinction ratio, the insertion loss and the bandwidth are also discussed. The results show that a TM-pass polarizer, which only guides the TM mode, can be achieved by multilayer graphene polymer waveguide. With length of 150 μm, the proposed polarizer can achieve extinction ratio of 33 dB and insertion loss of 0.5 dB at optical wavelength of 1.55 μm. This device has an excellent performance, including large extinction ratio and low insertion loss within the spectral range from 1.45 μm to 1.6 μm.

  6. Terahertz broadband polarization converter based on metamaterials

    Science.gov (United States)

    Li, Yonghua; Zhao, Guozhong

    2018-01-01

    Based on the metamaterial composed of symmetrical split resonant ring, a broadband reflective terahertz polarization converter is proposed. The numerical simulation shows that it can rotate the polarization direction of linear polarized wave 90° in the range of 0.7-1.8THz and the polarization conversion ratio is over 90%. The reflection coefficient of the two electric field components in the diagonal direction is the same and the phase difference is 180° ,which leads to the cross-polarization rotation.In order to further study the physical mechanism of high polarization conversion, we analyze the surface current distribution of the resonant ring. The polarization converter has potential applications in terahertz wave plate and metamaterial antenna design.

  7. Comparison of Different Compression to Ventilation Ratios (2: 1, 3: 1, and 4: 1) during Cardiopulmonary Resuscitation in a Porcine Model of Neonatal Asphyxia.

    Science.gov (United States)

    Pasquin, Matteo P; Cheung, Po-Yin; Patel, Sparsh; Lu, Min; Lee, Tze-Fun; Wagner, Michael; O'Reilly, Megan; Schmölzer, Georg M

    2018-04-12

    High-quality chest compression is essential during neonatal cardiopulmonary resuscitation (CPR). However, the optimal compression to ventilation ratio (C:V) that should be used during neonatal CPR to optimize coronary and cerebral perfusion while providing adequate ventilation remains unknown. We hypothesized that different C:V ratios (e.g., 2: 1 or 4: 1) will reduce the time to return of spontaneous circulation (ROSC) in severely asphyxiated piglets. Thirty-one newborn piglets (1-4 days old) were anesthetized, intubated, instrumented, and exposed to 50-min normocapnic hypoxia followed by asphyxia. Piglets were randomized into 4 groups: 2: 1 (n = 8), 3: 1 (n = 8), 4: 1 (n = 8) C:V ratio, or a sham group (n = 7). Cardiac function, carotid blood flow, cerebral oxygenation, and respiratory parameters were continuously recorded throughout the experiment. Thirty-one piglets were included in the study, and there was no difference in the duration of asphyxia or the degree of asphyxiation (as indicated by pH, PaCO2, and lactate) among the different groups. The median (IQR) time to ROSC was similar between the groups with 127 (82-210), 96 (88-126), and 119 (83-256) s in the 2: 1, 3: 1, and 4: 1 C:V ratio groups, respectively (p = 0.67 between groups). Similarly, there was no difference in 100% oxygen requirement or epinephrine administration between the experimental groups. Different C:V ratios resulted in similar ROSC, mortality, oxygen, and epinephrine administration during resuscitation in a porcine model of neonatal asphyxia. © 2018 S. Karger AG, Basel.

  8. Update of the Polar SWIFT model for polar stratospheric ozone loss (Polar SWIFT version 2)

    Science.gov (United States)

    Wohltmann, Ingo; Lehmann, Ralph; Rex, Markus

    2017-07-01

    The Polar SWIFT model is a fast scheme for calculating the chemistry of stratospheric ozone depletion in polar winter. It is intended for use in global climate models (GCMs) and Earth system models (ESMs) to enable the simulation of mutual interactions between the ozone layer and climate. To date, climate models often use prescribed ozone fields, since a full stratospheric chemistry scheme is computationally very expensive. Polar SWIFT is based on a set of coupled differential equations, which simulate the polar vortex-averaged mixing ratios of the key species involved in polar ozone depletion on a given vertical level. These species are O3, chemically active chlorine (ClOx), HCl, ClONO2 and HNO3. The only external input parameters that drive the model are the fraction of the polar vortex in sunlight and the fraction of the polar vortex below the temperatures necessary for the formation of polar stratospheric clouds. Here, we present an update of the Polar SWIFT model introducing several improvements over the original model formulation. In particular, the model is now trained on vortex-averaged reaction rates of the ATLAS Chemistry and Transport Model, which enables a detailed look at individual processes and an independent validation of the different parameterizations contained in the differential equations. The training of the original Polar SWIFT model was based on fitting complete model runs to satellite observations and did not allow for this. A revised formulation of the system of differential equations is developed, which closely fits vortex-averaged reaction rates from ATLAS that represent the main chemical processes influencing ozone. In addition, a parameterization for the HNO3 change by denitrification is included. The rates of change of the concentrations of the chemical species of the Polar SWIFT model are purely chemical rates of change in the new version, whereas in the original Polar SWIFT model, they included a transport effect caused by the

  9. Strain measurement in and analysis for hydraulic test of CPR1000 reactor pressure vessel

    International Nuclear Information System (INIS)

    Zhou Dan; Zhuang Dongzhen

    2013-01-01

    The strain measurement in hydraulic test of CPR1000 reactor pressure vessel performed in Dongfang Heavy Machinery Co., Ltd. is introduced. The detail test scheme and method was introduced and the measurement results of strain and stress was given. Meanwhile the finite element analysis was performed for the pressure vessel, which was generally matched with the measurement results. The reliability of strain measurement was verified and the high strength margin of vessel was shown, which would give a good reference value for the follow-up hydraulic tests and strength analysis of reactor pressure vessel. (authors)

  10. Optimum measurement and analysis of small polarization asymmetry in high-energy inelastic scattering using a polarized target

    International Nuclear Information System (INIS)

    Niinikoski, T.O.

    1976-01-01

    Optimum linear filter theory is employed for maximizing the signal-to-noise ratio in measurements of small polarization asymmetry in the presence of severe counting efficiency fluctuation, most likely to occur in high-energy inclusive and inelastic scattering experiments, using a polarized target. The r.m.s. error of the polarization asymmetry is obtained in closed form, allowing numeric optimization of the operation of the target. Guidelines are given for processing the record of data. (Auth.)

  11. Arbitrary helicity control of circularly polarized light from lateral-type spin-polarized light-emitting diodes at room temperature

    Science.gov (United States)

    Nishizawa, Nozomi; Aoyama, Masaki; Roca, Ronel C.; Nishibayashi, Kazuhiro; Munekata, Hiro

    2018-05-01

    We demonstrate arbitrary helicity control of circularly polarized light (CPL) emitted at room temperature from the cleaved side facet of a lateral-type spin-polarized light-emitting diode (spin-LED) with two ferromagnetic electrodes in an antiparallel magnetization configuration. Driving alternate currents through the two electrodes results in polarization switching of CPL with frequencies up to 100 kHz. Furthermore, tuning the current density ratio in the two electrodes enables manipulation of the degree of circular polarization. These results demonstrate arbitrary electrical control of polarization with high speed, which is required for the practical use of lateral-type spin-LEDs as monolithic CPL light sources.

  12. Analysis of signal to background ratio in synchrotron radiation X-ray fluorescence

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Gohshi, Yohichi; Iida, Atsuo.

    1988-01-01

    The signal to background (S/B) ratio in energy dispersive X-ray fluorescence using synchrotron radiation (SR) was quantitatively analyzed. The S/B ratio, which has been significantly improved by taking advantage of the polarized nature of SR, was found to be strongly dependent on geometrical factors of the measurement system. From the analysis on the origin of the scattered background, the dependence of the S/B ratio on the geometry was quantitatively explained, mainly by the polarization properties of SR. Experimental conditions could be optimized by adjusting the degree of polarization of the incident beam and the detector solid angle. (author)

  13. Update of the Polar SWIFT model for polar stratospheric ozone loss (Polar SWIFT version 2

    Directory of Open Access Journals (Sweden)

    I. Wohltmann

    2017-07-01

    Full Text Available The Polar SWIFT model is a fast scheme for calculating the chemistry of stratospheric ozone depletion in polar winter. It is intended for use in global climate models (GCMs and Earth system models (ESMs to enable the simulation of mutual interactions between the ozone layer and climate. To date, climate models often use prescribed ozone fields, since a full stratospheric chemistry scheme is computationally very expensive. Polar SWIFT is based on a set of coupled differential equations, which simulate the polar vortex-averaged mixing ratios of the key species involved in polar ozone depletion on a given vertical level. These species are O3, chemically active chlorine (ClOx, HCl, ClONO2 and HNO3. The only external input parameters that drive the model are the fraction of the polar vortex in sunlight and the fraction of the polar vortex below the temperatures necessary for the formation of polar stratospheric clouds. Here, we present an update of the Polar SWIFT model introducing several improvements over the original model formulation. In particular, the model is now trained on vortex-averaged reaction rates of the ATLAS Chemistry and Transport Model, which enables a detailed look at individual processes and an independent validation of the different parameterizations contained in the differential equations. The training of the original Polar SWIFT model was based on fitting complete model runs to satellite observations and did not allow for this. A revised formulation of the system of differential equations is developed, which closely fits vortex-averaged reaction rates from ATLAS that represent the main chemical processes influencing ozone. In addition, a parameterization for the HNO3 change by denitrification is included. The rates of change of the concentrations of the chemical species of the Polar SWIFT model are purely chemical rates of change in the new version, whereas in the original Polar SWIFT model, they included a transport effect

  14. The process and risk of the CPR1000 cold function test in the cold area

    International Nuclear Information System (INIS)

    Liu Tinghao; Zhang Jian; Ji Dapeng; Shi Quanjian; Tian Kuo

    2014-01-01

    Hong yanhe nuclear power station is the first CPR1000 reactor which is under construction in the cold area of north China. It is also the first time to carry out the cold functional test (CFT) in the winter of north China. The preparation and process of CFT are described in the paper. According to the experience feedback of CFT of Unit 1, the risk and solution which are significance for the CFT of the other NPS in the cold area are analysed. (authors)

  15. Ultracompact and broadband polarization beam splitter based on polarization-dependent critical guiding condition.

    Science.gov (United States)

    Ying, Zhoufeng; Wang, Guanghui; Zhang, Xuping; Ho, Ho-pui; Huang, Ying

    2015-05-01

    An ultracompact and broadband polarization beam splitter (PBS) based on the polarization-dependent critical guiding condition of an asymmetrical directional coupler is proposed. The device consists of a pair of silicon waveguides with different height and width. Due to the different cutoff conditions for the TE and TM polarization modes, it is possible to have the TM mode guided in one waveguide while the TE mode is supported in both. Therefore, only the phase-matching condition for the cross-coupling of the TE mode needs to be considered. This approach not only simplifies the design procedures but also significantly improves device performance with smaller total length and larger bandwidth. Finally, regardless of the contribution of S-bend waveguides, our proposed PBS has a coupling region as short as 0.2 μm, which is the shortest reported until now. The simulation result shows that the extinction ratios for the TE and TM polarization are 13.5 and 16.6 dB at their respective output ports, and their insertion losses are 0.29 and 0.13 dB, respectively. Numerical simulations also show that the device offers a very large bandwidth (∼140  nm) with large extinction ratio (>10  dB) and low insertion loss (<1  dB).

  16. Deep-etched sinusoidal polarizing beam splitter grating.

    Science.gov (United States)

    Feng, Jijun; Zhou, Changhe; Cao, Hongchao; Lv, Peng

    2010-04-01

    A sinusoidal-shaped fused-silica grating as a highly efficient polarizing beam splitter (PBS) is investigated based on the simplified modal method. The grating structure depends mainly on the ratio of groove depth to grating period and the ratio of incident wavelength to grating period. These ratios can be used as a guideline for the grating design at different wavelengths. A sinusoidal-groove PBS grating is designed at a wavelength of 1310 nm under Littrow mounting, and the transmitted TM and TE polarized waves are mainly diffracted into the zeroth order and the -1st order, respectively. The grating profile is optimized by using rigorous coupled-wave analysis. The designed PBS grating is highly efficient (>95.98%) over the O-band wavelength range (1260-1360 nm) for both TE and TM polarizations. The sinusoidal grating can exhibit higher diffraction efficiency, larger extinction ratio, and less reflection loss than the rectangular-groove PBS grating. By applying wet etching technology on the rectangular grating, which was manufactured by holographic recording and inductively coupled plasma etching technology, the sinusoidal grating can be approximately fabricated. Experimental results are in agreement with theoretical values.

  17. Optimal Chest Compression Rate and Compression to Ventilation Ratio in Delivery Room Resuscitation: Evidence from Newborn Piglets and Neonatal Manikins

    OpenAIRE

    Solev?g, Anne Lee; Schm?lzer, Georg M.

    2017-01-01

    Cardiopulmonary resuscitation (CPR) duration until return of spontaneous circulation (ROSC) influences survival and neurologic outcomes after delivery room (DR) CPR. High quality chest compressions (CC) improve cerebral and myocardial perfusion. Improved myocardial perfusion increases the likelihood of a faster ROSC. Thus, optimizing CC quality may improve outcomes both by preserving cerebral blood flow during CPR and by reducing the recovery time. CC quality is determined by rate, CC to vent...

  18. A Comparison Of Internet-Based Learning And Traditional Classroom Lecture To Learn Cpr For Continuing Medical Education

    OpenAIRE

    HEMMATI, Nima; OMRANI, Soghra; HEMMATI, Naser

    2013-01-01

    The purpose of this study was to compare the satisfaction and effectiveness of Internet-based learning (IBL) and traditional classroom lecture (TCL) for continuing medical education (CME) programs by comparing final resuscitation exam results of physicians who received the newest cardiopulmonary resuscitation (CPR) curriculum guidelines training either by traditional or by an Internet-based CME. A randomized two-group pretest-posttest quasi-experimental design was used. Postgraduate general ...

  19. Atomic processes relevant to polarization plasma spectroscopy

    International Nuclear Information System (INIS)

    Fujimoto, T.; Koike, F.; Sakimoto, K.; Okasaka, R.; Kawasaki, K.; Takiyama, K.; Oda, T.; Kato, T.

    1992-04-01

    When atoms (ions) are excited anisotropically, polarized excited atoms are produced and the radiation emitted by these atoms is polarized. From the standpoint of plasma spectroscopy research, we review the existing data for various atomic processes that are related to the polarization phenomena. These processes are: electron impact excitation, excitation by atomic and ionic collisions, photoexcitation, radiative recombination and bremsstrahlung. Collisional and radiative relaxation processes of atomic polarization follow. Other topics included are: electric-field measurement, self alignment, Lyman doublet intensity ratio, and magnetic-field measurement of the solar prominence. (author)

  20. Ratio of νe/νμ in atmospheric neutrinos

    International Nuclear Information System (INIS)

    Barr, S.; Gaisser, T.K.; Tilav, S.

    1988-01-01

    When the effect of muon polarization is included, the calculated ratio ν e /ν μ for atmospheric neutrinos with energies above ≅ 200 MeV is increased by 10-20% compared to the result when polarization is neglected. We give an analytic derivation of this ratio for the artificial case of a power law differential spectrum of parent pions propagating in an atmosphere in which all pions and muons decay. This is sufficient to estimate the effect on the calculated ratio of electron-like to muon-like events induced by neutrino interactions in large underground detectors. (orig.)

  1. Polarization splitter based on interference effects in all-solid photonic crystal fibers.

    Science.gov (United States)

    Mao, Dong; Guan, Chunying; Yuan, Libo

    2010-07-01

    We propose a novel kind of polarization splitter in all-solid photonic crystal fibers based on the mode interference effects. Both the full-vector finite-element method and the semi-vector three-dimensional beam propagation method are employed to design and analyze the characteristics of the splitter. Numerical simulations show that x-polarized and y-polarized modes are split entirely along with 6.8 mm long propagation. An extinction ratio of more than 20 dB and a crosstalk of less than -20 dB are obtained within the wavelength range of 1.541-1.556 microm. The extinction ratio and the crosstalk at 1.55 microm are 28.9 and -29.0 dB for x polarization, while the extinction ratio and the crosstalk at 1.55 microm are 29.9 and -29.8 dB for y polarization, respectively.

  2. Polarimetric imaging of retinal disease by polarization sensitive SLO

    Science.gov (United States)

    Miura, Masahiro; Elsner, Ann E.; Iwasaki, Takuya; Goto, Hiroshi

    2015-03-01

    Polarimetry imaging is used to evaluate different features of the macular disease. Polarimetry images were recorded using a commercially- available polarization-sensitive scanning laser opthalmoscope at 780 nm (PS-SLO, GDx-N). From data sets of PS-SLO, we computed average reflectance image, depolarized light images, and ratio-depolarized light images. The average reflectance image is the grand mean of all input polarization states. The depolarized light image is the minimum of crossed channel. The ratio-depolarized light image is a ratio between the average reflectance image and depolarized light image, and was used to compensate for variation of brightness. Each polarimetry image is compared with the autofluorescence image at 800 nm (NIR-AF) and autofluorescence image at 500 nm (SW-AF). We evaluated four eyes with geographic atrophy in age related macular degeneration, one eye with retinal pigment epithelium hyperplasia, and two eyes with chronic central serous chorioretinopathy. Polarization analysis could selectively emphasize different features of the retina. Findings in ratio depolarized light image had similarities and differences with NIR-AF images. Area of hyper-AF in NIR-AF images showed high intensity areas in the ratio depolarized light image, representing melanin accumulation. Areas of hypo-AF in NIR-AF images showed low intensity areas in the ratio depolarized light images, representing melanin loss. Drusen were high-intensity areas in the ratio depolarized light image, but NIR-AF images was insensitive to the presence of drusen. Unlike NIR-AF images, SW-AF images showed completely different features from the ratio depolarized images. Polarization sensitive imaging is an effective tool as a non-invasive assessment of macular disease.

  3. Amplitude ratios in ρ0 leptoproductions and GPDs

    Directory of Open Access Journals (Sweden)

    Goloskokov S.V.

    2017-01-01

    Using the model results we calculate the ratio of different helicity amplitudes for a transversely polarized proton target to the leading twist longitudinal amplitude. Our results are close to the amplitude ratios measured by HERMES.

  4. Inkjet printed circularly polarized antennas for GPS applications

    KAUST Repository

    Farooqui, Muhammad Fahad

    2014-07-01

    Two novel, inkjet printed circularly polarized antenna designs are presented for GPS applications. First antenna design comprises a planar monopole which has been made circularly polarized by the introduction of an L-shaped slit. The antenna shows a gain of 0.2 dBi at 1.575 GHz with 3-dB axial ratio bandwidth of 3.8%. The second antenna design comprises a modified monopole in the form of an inverted L and has been termed as circularly polarized inverted L antenna (CILA). The antenna shows a gain of -2 dBi at 1.575 GHz with 3-dB axial ratio bandwidth of 4.1%. Both the antenna designs are attractive for mobile applications.

  5. Reference centiles for the middle cerebral artery and umbilical artery pulsatility index and cerebro-placental ratio from a low-risk population - a Generalised Additive Model for Location, Shape and Scale (GAMLSS) approach.

    Science.gov (United States)

    Flatley, Christopher; Kumar, Sailesh; Greer, Ristan M

    2018-02-06

    The primary aim of this study was to create reference ranges for the fetal Middle Cerebral artery Pulsatility Index (MCA PI), Umbilical Artery Pulsatility Index (UA PI) and the Cerebro-Placental Ratio (CPR) in a clearly defined low-risk cohort using the Generalised Additive Model for Location, Shape and Scale (GAMLSS) method. Prospectively collected cross-sectional biometry and Doppler data from low-risk women attending the Mater Mother's Hospital, Maternal and Fetal Medicine Department in Brisbane, Australia between January 2010 and April 2017 were used to derive gestation specific centiles for the MCA PI, UA PI and CPR. All ultrasound scans were performed between 18 + 0 and 41 + 6 weeks gestation with recorded data for the MCA PI and/or UA PI. The GAMLSS method was used for the calculation of gestational age-adjusted centiles. Distributions and additive terms were assessed and the final model was chosen on the basis of the Global Deviance, Akaike information criterion (AIC) and Schwartz bayesian criterion (SBC), along with the results of the model and residual diagnostics as well as visual assessment of the centiles themselves. Over the study period 6013 women met the inclusion criteria. The MCA PI was recorded in 4473 fetuses, the UA PI in 6008 fetuses and the CPR was able to be calculated in 4464 cases. The centiles for the MCA PI used a fractional polynomial additive term and Box-Cox t (BCT) distribution. Centiles for the UA PI used a cubic spline additive term with BCT distribution and the CPR used a fractional polynomial additive term and a BCT distribution. We have created gestational centile reference ranges for the MCA PI, UA PI and CPR from a large low-risk cohort that supports their applicability and generalisability.

  6. Backscattering and negative polarization of agglomerate particles.

    Science.gov (United States)

    Zubko, Evgenij; Shkuratov, Yuriy; Hart, Matthew; Eversole, Jay; Videen, Gorden

    2003-09-01

    We used the discrete dipole approximation to study the backscattering of agglomerate particles consisting of oblong monomers. We varied the aspect ratio of the monomers from approximately 1 (sphere) to 4, while we kept the total particle volume equivalent to that of an x = 10 sphere for m = 1.59 + i0 and 1.50 + i0 and considered two values of agglomerate packing density: rho = 0.25 and rho = 0.1. We found that these particles do not display a prominent brightness opposition effect but do produce significant negative polarization over a range of near-backscattering angles. Increasing the monomers' aspect ratio can make the negative polarization much more prominent. We have noted also that decreasing m and p can reduce the amplitude of the negative polarization for these particles.

  7. Neutron polarizing set-up of the Sofia IRT research reactor

    International Nuclear Information System (INIS)

    Krezhov, K.; Mikhajlova, V.; Okorokov, A.

    1990-01-01

    Neutron polarizing set-up of one of the horizontal beam tubes of the IRT-200 research reactor of the Bulgarian Institute of Nuclear Research and Nuclear Energy is presented. Neutron mirrors are extensively used in an effort to compensate the moderate reactor beam intensity by the high reflected intensity and wide-band transmittance of the mirror neutron guides. Time-to-flight technique using a slotted neutron absorbing chopper with a horizontal rotation axis has been applied to obtain the exit neutron spectra. Beam polarization and flipping ratios have been determined. Cadmium ratio in the polarized beam has been found almost 10 4 and the average polarization has been measured to be higher than 96%. 3 figs, 3 refs

  8. Study of Branching Ratio And Polarization Fraction in Neutral B Meson Decays to Negative Rho Meson Positive Kaon Resonance

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Baosen; /Wisconsin U., Madison

    2006-03-07

    We present the preliminary results on the search for B{sup 0} {yields} {rho}{sup -}K*{sup +}. The data sample comprises 122.7 million B{bar B} pairs in the e{sup +}e{sup -} annihilation through the {Upsilon}(4S) resonance collected during 1999-2003 with the BABAR detector at the PEP-II asymmetric-energy collider at Stanford Linear Accelerator Center (SLAC). We obtain an upper limit of the branching ratio at 90% confidence level as {Beta}(B{sup 0} {yields} {rho}{sup -}K*{sup +}) < 17.2 x 10{sup -6}. The fitted result on the polarization fraction shows no evidence that the decay is longitudinally dominated as predicted by various theoretical models.

  9. Spin-polarized fuel in ICF pellets

    International Nuclear Information System (INIS)

    Wakuta, Yoshihisa; Emoto, Nobuya; Nakao, Yasuyuki; Honda, Takuro; Honda, Yoshinori; Nakashima, Hideki.

    1990-01-01

    The use of parallel spin-polarized DT or D 3 He fuel increases the fusion cross-section by 50%. By implosion-burn simulation for inertially confined fusion (ICF) pellets of the spin-polarized fuels, we found that the input energy requirement could be reduced by nearly a fact of two. These pellets taken up here include large-high-aspect-ratio DT target proposed in ILE Osaka University and DT ignitor/D 3 He fuel pellet proposed by our group. We also found that the polarized state could survive during the implosion-burn phase. (author)

  10. Radiotherapy high energy surface dose measurements: effects of chamber polarity

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: The effects of chamber polarity have been investigated for the measurement of 6MV and 18MV x-ray surface dose using a parallel plate ionization chamber. Results have shown that a significant difference in measured ionization is recorded between to polarities at 6MV and 18MV at the phantom surface. A polarity ratio ranging from 1 062 to 1 005 is seen for 6MV x-rays at the phantom surface for field sizes 5cm x 5cm to 40cm x 40cm when comparing positive to negative polarity. These ratios range from 1.024 to 1.004 for 18MV x-rays with the same field sizes. When these charge reading are compared to the D max readings of the same polarity it is found that these polarity effects are minimal for the calculation of percentage dose results with variations being less than 1% of maximum. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  11. ON ELLIPTICALLY POLARIZED ANTENNAS IN THE PRESENCE OF GROUND

    Science.gov (United States)

    The effect of ground reflections upon the far field of an elliptically polarized antenna of ar itrary orientation with r spect to ground is...investigated. The equation of the polarization ellipse produced by an elliptically polarized antenna in the presence of ground is derived, AND SEVERAL...EXAMPLES ILLUSTRATE THE VARIATION IN THE AXIS RATIO OF THE POLARIZATION ELLIPSE AS A FUNCTION OF THE GEOMETRY OF THE MEASURING SETUP. A method is presented

  12. Early leaf senescence is associated with an altered cellular redox balance in Arabidopsis cpr5/old1 mutants

    OpenAIRE

    Jing, H. -C.; Hebeler, R.; Oeljeklaus, S.; Sitek, B.; Stuehler, K.; Meyer, H. E.; Sturre, M. J. G.; Hille, J.; Warscheid, B.; Dijkwel, P. P.; Stühler, K.

    2008-01-01

    Reactive oxygen species (ROS) are the inevitable by-products of essential cellular metabolic and physiological activities. Plants have developed sophisticated gene networks of ROS generation and scavenging systems. However, ROS regulation is still poorly understood. Here, we report that mutations in the Arabidopsis CPR5/OLD1 gene may cause early senescence through deregulation of the cellular redox balance. Genetic analysis showed that blocking stress-related hormonal signalling pathways, suc...

  13. The Polarization of Achernar

    Science.gov (United States)

    McDavid, D.

    2005-11-01

    Recent near-infrared measurements of the angular diameter of Achernar (the bright Be star alpha Eridani) with the ESO VLT interferometer have been interpreted as the detection of an extremely oblate photosphere, with a ratio of equatorial to polar radius of at least 1.56 ± 0.05 and a minor axis orientation of 39° ± 1° (from North to East). The optical linear polarization of this star during an emission phase in 1995 September was 0.12 ± 0.02% at position angle 37° ± 8° (in equatorial coordinates), which is the direction of the projection of the rotation axis on the plane of the sky according to the theory of polarization by electron scattering in an equatorially flattened circumstellar disk. These two independent determinations of the orientation of the rotation axis are therefore in agreement. The observational history of correlations between Hα emission and polarization as found in the literature is that of a typical Be star, with the exception of an interesting question raised by the contrast between Schröder's measurement of a small polarization perpendicular to the projected rotation axis in 1969--70 and Tinbergen's measurement of zero polarization in 1974.5, both at times when emission was reportedly absent.

  14. Neonatal CPR: room at the top—a mathematical study of optimal chest compression frequency versus body size

    OpenAIRE

    Babbs, Charles F; Meyer, Andrew; Nadkarni, Vinay

    2009-01-01

    Objective: To explore in detail the expected magnitude of systemic perfusion pressure during standard CPR as a function of compression frequency for different sized people from neonate to adult. Method: A 7-compartment mathematical model of the human cardiopulmonary system—upgraded to include inertance of blood columns in the aorta and vena cavae—was exercised with parameters scaled to reflect changes in body weight from 1 to 70 kg. Results: Maximal systemic perfusion pressure occurs at chest...

  15. Basic-CPR and AIDS: are volunteer life-savers prepared for a storm?

    Science.gov (United States)

    Bierens, J J; Berden, H J

    1996-10-01

    Professional health care workers have access to guidelines, equipment and techniques to reduce the exposure to infectious material in case of resuscitation. The current official content of national courses for volunteer life-savers do not address this issue, as far as we know. Concern about the risks of infection due to resuscitation is increasing in this group. This article describes a rational approach of the problem, that includes data on the infection risk of basic-CPR, and an approach that accepts that the concern can not be controlled by objective data. In such an emotional approach, direct contact has to be minimised by using devices. Requirements for resuscitation devices with a barrier function are listed. Although both approaches will reduce the fear of infection, we advice a rational approach.

  16. Full vessel CFD analysis on thermal-hydraulic characteristics of CPR1000 PWR

    International Nuclear Information System (INIS)

    Chao Yanmeng; Yang Lixin; Zhang Mingqian

    2014-01-01

    To obtain flow distributions and thermal-hydraulic properties in a full vessel PWR under limited computation ability and time, a full vessel simulation model of CPR1000 was built based on two simplification methods. One simplified the inner geometry of the control rod guide tubes using equivalent flow area. Another substituted the core by a porous domain to maintain the pressure drop and temperature rise. After the computation, global and localized flow distributions, hydraulic loads of some main assemblies were obtained, as well as other thermal-hydraulic properties. The results indicate the flow distribution in the full vessel is asymmetrical. Therefore it is essential to use the full vessel model to simulate. The calculated thermal-hydraulic characteristics agree well with the operation statistics, providing the reference data for the reactor safety operation. (authors)

  17. Development of atmospheric polarization LIDAR System

    International Nuclear Information System (INIS)

    Ghalumyan, A.S.; Ghazaryan, V.R.

    2016-01-01

    LIDAR (Light Detection And Ranging) system sensitive to the polarization of the backscattered signal is being developed in Yerevan Physics Institute. The system is designed primarily for remote sensing of the atmospheric electric fields. At present, the system is being tuned for measuring vertical atmospheric backscatter profiles of aerosols and hydrometeors, analyze the depolarization ratio of elastic backscattered laser beams and investigate the influence of external factors on the beam polarization. In this paper, we describe the complete LIDAR system – the laser transmitter, receiving telescope and the polarization separator. The data acquisition and processing techniques are also described. (author)

  18. A COMPARISON OF INTERNET-BASED LEARNING AND TRADITIONAL CLASSROOM LECTURE TO LEARN CPR FOR CONTINUING MEDICAL EDUCATION

    Directory of Open Access Journals (Sweden)

    Naser HEMMATI

    2013-01-01

    Full Text Available The purpose of this study was to compare the satisfaction and effectiveness of Internet-based learning (IBL and traditional classroom lecture (TCL for continuing medical education (CME programs by comparing final resuscitation exam results of physicians who received the newest cardiopulmonary resuscitation (CPR curriculum guidelines training either by traditional or by an Internet-based CME. A randomized two-group pretest-posttest quasi-experimental design was used. Postgraduate general physician trainees of Iran medical schools were participated. Two methods were compared for teaching the newest curriculum guidelines of the American Heart Association: lecture method in which the teacher follows a Power point presentation with linear layout, and with interactive self-assessment and Scenario-based learning, feedback, multimedia with linear and nonlinear layout with the same power point presentation as lecture in terms of text and photography. The data on final CPR exam grades, collected both groups trained physicians, were obtained for a total of 80 physicians in 2011. An independent sample t-test analysis indicated that participants in the IBL format reported significantly higher mean ratings for this format (62.5 ±2.32 than TCL format (54.6±2.18 (p=.001. There were no significant differences between the two groups in cognitive gains (p<0.05. well-designed IBL content can be effective or a supplement component to CME.

  19. Log-periodic dipole antenna with low cross-polarization

    DEFF Research Database (Denmark)

    Pivnenko, Sergey

    2006-01-01

    In this work, log-periodic antennas with improved cross-polarization level were studied. It was found that some modifications of the traditional design lead to an essential improvement of the co-to-cross polarization ratio up to 40 dB. An improved design of a log-periodic dipole antenna with low...

  20. Carbon nanotube fiber terahertz polarizer

    Energy Technology Data Exchange (ETDEWEB)

    Zubair, Ahmed [Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005 (United States); Tsentalovich, Dmitri E.; Young, Colin C. [Department of Chemical and Biomolecular Engineering, Rice University, Houston, Texas 77005 (United States); Heimbeck, Martin S. [Charles M. Bowden Laboratory, Aviation & Missile Research, Development, and Engineering Center (AMRDEC), Redstone Arsenal, Alabama 35898 (United States); Everitt, Henry O. [Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005 (United States); Charles M. Bowden Laboratory, Aviation & Missile Research, Development, and Engineering Center (AMRDEC), Redstone Arsenal, Alabama 35898 (United States); Pasquali, Matteo [Department of Chemical and Biomolecular Engineering, Rice University, Houston, Texas 77005 (United States); Department of Chemistry, Rice University, Houston, Texas 77005 (United States); Department of Materials Science and NanoEngineering, Rice University, Houston, Texas 77005 (United States); Kono, Junichiro, E-mail: kono@rice.edu [Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005 (United States); Department of Materials Science and NanoEngineering, Rice University, Houston, Texas 77005 (United States); Department of Physics and Astronomy, Rice University, Houston, Texas 77005 (United States)

    2016-04-04

    Conventional, commercially available terahertz (THz) polarizers are made of uniformly and precisely spaced metallic wires. They are fragile and expensive, with performance characteristics highly reliant on wire diameters and spacings. Here, we report a simple and highly error-tolerant method for fabricating a freestanding THz polarizer with nearly ideal performance, reliant on the intrinsically one-dimensional character of conduction electrons in well-aligned carbon nanotubes (CNTs). The polarizer was constructed on a mechanical frame over which we manually wound acid-doped CNT fibers with ultrahigh electrical conductivity. We demonstrated that the polarizer has an extinction ratio of ∼−30 dB with a low insertion loss (<0.5 dB) throughout a frequency range of 0.2–1.1 THz. In addition, we used a THz ellipsometer to measure the Müller matrix of the CNT-fiber polarizer and found comparable attenuation to a commercial metallic wire-grid polarizer. Furthermore, based on the classical theory of light transmission through an array of metallic wires, we demonstrated the most striking difference between the CNT-fiber and metallic wire-grid polarizers: the latter fails to work in the zero-spacing limit, where it acts as a simple mirror, while the former continues to work as an excellent polarizer even in that limit due to the one-dimensional conductivity of individual CNTs.

  1. 75 FR 10026 - Proposed Collection; Comment Request for Forms W-2, W-2c, W-2AS, W-2GU, W-2VI, W-3, W-3c, W-3cPR...

    Science.gov (United States)

    2010-03-04

    ... W-2, W-2c, W-2AS, W-2GU, W-2VI, W-3, W-3c, W-3cPR, W-3PR, and W-3SS AGENCY: Internal Revenue Service....C. 3506(c)(2)(A)). Currently, the IRS is soliciting comments concerning Forms W-2, W-2c, W-2AS, W-2GU, W-2VI, W-3, W-3c, W- 3cPR, W-3PR, and W-3SS. DATES: Written comments should be received on or...

  2. 3D printed polarizing grids for IR-THz synchrotron radiation

    Science.gov (United States)

    Ryu, Meguya; Linklater, Denver; Hart, William; Balčytis, Armandas; Skliutas, Edvinas; Malinauskas, Mangirdas; Appadoo, Dominique; Tan, Yaw-Ren Eugene; Ivanova, Elena P.; Morikawa, Junko; Juodkazis, Saulius

    2018-03-01

    Grid polarisers 3D-printed out of commercial acrilic resin were tested for the polariser function and showed spectral regions where the dichroic ratio {D}R> 1 and The used 3D printing method allows for fabrication of an arbitrary high aspect ratio grid polarisers. Polarization analysis of synchrotron THz radiation was carried out with a standard stretched polyethylene polariser and revealed that the linearly polarized (horizontal) component contributes up to 22% ± 5% to the circular polarized synchrotron emission extracted by a gold-coated mirror with a horizontal slit inserted near the bending magnet edge. Comparison with theoretical predictions shows a qualitative match with dominance of the edge radiation.

  3. Preliminary Analysis of Chinese GF-3 SAR Quad-Polarization Measurements to Extract Winds in Each Polarization

    Directory of Open Access Journals (Sweden)

    Lin Ren

    2017-11-01

    Full Text Available This study analyzed the noise equivalent sigma zero (NESZ and ocean wind sensitivity for Chinese C-band Gaofen-3 (GF-3 quad-polarization synthetic aperture radar (SAR measurements to facilitate further operational wind extraction from GF-3 data. Data from the GF-3 quad-polarization SAR and collocated winds from both NOAA/NCEP Global Forecast System (GFS atmospheric model and National Data Buoy Center (NDBC buoys were used in the analysis. For NESZ, the co-polarization was slightly higher compared to the cross-polarization. Regarding co-polarization and cross-polarization, NESZ was close to RadarSAT-2 and Sentinel-1 A. Wind sensitivity was analyzed by evaluating the dependence on winds in terms of normalized radar cross-sections (NRCS and polarization combinations. The closest geophysical model function (GMF and the polarization ratio (PR model to GF-3 data were determined by comparing data and the model results. The dependence of co-polarized NRCS on wind speed and azimuth angle was consistent with the proposed GMF models. The combination of CMOD5 and CMOD5.N was considered to be the closest GMF in co-polarization. The cross-polarized NRCS exhibited a strong linear relationship with moderate wind speeds higher than 4 m·s−1, but a weak correlation with the azimuth angle. The proposed model was considered as the closest GMF in cross-polarization. For polarization combinations, PR and polarization difference (PD were considered. PR increased only with the incidence angle, whereas PD increased with wind speed and varied with azimuth angle. There were three very close PR models and each can be considered as the closest. Preliminary results indicate that GF-3 quad-polarization data are valid and have the ability to extract winds in each polarization.

  4. Observation of interface dependent spin polarized photocurrents in InAs/GaSb superlattice

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yuan, E-mail: liyuan12@semi.ac.cn; Liu, Yu; Zhu, Laipan; Qin, Xudong; Wu, Qing; Huang, Wei; Chen, Yonghai, E-mail: yhchen@semi.ac.cn [Key Laboratory of Semiconductor Materials Science, Institute of Semiconductors, Chinese Academy of Sciences, 100083 Beijing (China); Niu, Zhichuan; Xiang, Wei; Hao, Hongyue [The State Key Laboratory of Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, 100083 Beijing (China)

    2015-05-11

    In this letter, we investigated the spin polarized photocurrents excited by mid-infrared radiation and near-infrared radiation, respectively, in InAs/GaSb type II superlattices with different kinds of interfaces. By periodically varying the polarization state of the radiation, we analyzed Rashba-type and Dresselhaus-type spin polarized photocurrents, which present different features depending on the interface types and excitation conditions. Under mid-infrared excitation, the ratio of Rashba-type and Dresselhaus-type spin polarized photocurrents of the superlattice with InSb-like interface is obviously larger than that of the superlattice with GaAs-like interface, the ratio of the superlattice with alternate interface is in the middle. Whereas under near-infrared excitation, the ratios of the three superlattices are nearly the same. Further researches reveal the synactic effects of interface dependent strain and asymmetric interface potential on the spin splitting. Besides, the polarized Raman spectroscopies of these structures were also analyzed.

  5. Observation of interface dependent spin polarized photocurrents in InAs/GaSb superlattice

    International Nuclear Information System (INIS)

    Li, Yuan; Liu, Yu; Zhu, Laipan; Qin, Xudong; Wu, Qing; Huang, Wei; Chen, Yonghai; Niu, Zhichuan; Xiang, Wei; Hao, Hongyue

    2015-01-01

    In this letter, we investigated the spin polarized photocurrents excited by mid-infrared radiation and near-infrared radiation, respectively, in InAs/GaSb type II superlattices with different kinds of interfaces. By periodically varying the polarization state of the radiation, we analyzed Rashba-type and Dresselhaus-type spin polarized photocurrents, which present different features depending on the interface types and excitation conditions. Under mid-infrared excitation, the ratio of Rashba-type and Dresselhaus-type spin polarized photocurrents of the superlattice with InSb-like interface is obviously larger than that of the superlattice with GaAs-like interface, the ratio of the superlattice with alternate interface is in the middle. Whereas under near-infrared excitation, the ratios of the three superlattices are nearly the same. Further researches reveal the synactic effects of interface dependent strain and asymmetric interface potential on the spin splitting. Besides, the polarized Raman spectroscopies of these structures were also analyzed

  6. Interferometric crosstalk suppression using polarization multiplexing technique and an SOA

    DEFF Research Database (Denmark)

    Liu, Fenghai; Xueyan, Zheng; Pedersen, Rune Johan Skullerud

    2000-01-01

    Interferometric crosstalk can be greatly suppressed at 10Gb/s and 20Gb/s by using a gain saturated SOA and a polarization multiplexing technique that eliminates impairments like waveform and extinction ratio degradation from the SOA.......Interferometric crosstalk can be greatly suppressed at 10Gb/s and 20Gb/s by using a gain saturated SOA and a polarization multiplexing technique that eliminates impairments like waveform and extinction ratio degradation from the SOA....

  7. Hybrid fluorescent layer emitting polarized light

    Directory of Open Access Journals (Sweden)

    Mohammad Mohammadimasoudi

    2017-07-01

    Full Text Available Semiconductor nanorods have anisotropic absorption and emission properties. In this work a hybrid luminescent layer is produced based on a mixture of CdSe/CdS nanorods dispersed in a liquid crystal that is aligned by an electric field and polymerized by UV illumination. The film emits light with polarization ratio 0.6 (polarization contrast 4:1. Clusters of nanorods in liquid crystal can be avoided by applying an AC electric field with sufficient amplitude. This method can be made compatible with large-scale processing on flexible transparent substrates. Thin polarized light emitters can be used in LCD backlights or solar concentrators to increase the efficiency.

  8. Silicon photonic transceiver circuit for high-speed polarization-based discrete variable quantum key distribution.

    Science.gov (United States)

    Cai, Hong; Long, Christopher M; DeRose, Christopher T; Boynton, Nicholas; Urayama, Junji; Camacho, Ryan; Pomerene, Andrew; Starbuck, Andrew L; Trotter, Douglas C; Davids, Paul S; Lentine, Anthony L

    2017-05-29

    We demonstrate a silicon photonic transceiver circuit for high-speed discrete variable quantum key distribution that employs a common structure for transmit and receive functions. The device is intended for use in polarization-based quantum cryptographic protocols, such as BB84. Our characterization indicates that the circuit can generate the four BB84 states (TE/TM/45°/135° linear polarizations) with >30 dB polarization extinction ratios and gigabit per second modulation speed, and is capable of decoding any polarization bases differing by 90° with high extinction ratios.

  9. A New Kind of Circular Polarization Leaky-Wave Antenna Based on Substrate Integrated Waveguide

    Directory of Open Access Journals (Sweden)

    Chong Zhang

    2015-01-01

    Full Text Available A new kind of circular polarization leaky-wave antenna with N-shaped slots cut in the upper side of substrate integrated waveguide (SIW is investigated and presented. The radiation pattern and polarization axial ratio of the leaky-wave antenna are studied. The results show that the width of N-shaped slots has significant effect on the circular polarization property of the antenna. By properly choosing structural parameters, the SIW based leaky-wave antenna can realize circular polarization with excellent axial ratio in 8 GHz satellite band.

  10. Polarization modeling and predictions for DKIST part 3: focal ratio and thermal dependencies of spectral polarization fringes and optic retardance

    Science.gov (United States)

    Harrington, David M.; Sueoka, Stacey R.

    2018-01-01

    Data products from high spectral resolution astronomical polarimeters are often limited by fringes. Fringes can skew derived magnetic field properties from spectropolarimetric data. Fringe removal algorithms can also corrupt the data if the fringes and object signals are too similar. For some narrow-band imaging polarimeters, fringes change the calibration retarder properties and dominate the calibration errors. Systems-level engineering tools for polarimetric instrumentation require accurate predictions of fringe amplitudes, periods for transmission, diattenuation, and retardance. The relevant instabilities caused by environmental, thermal, and optical properties can be modeled and mitigation tools developed. We create spectral polarization fringe amplitude and temporal instability predictions by applying the Berreman calculus and simple interferometric calculations to optics in beams of varying F/ number. We then apply the formalism to superachromatic six-crystal retarders in converging beams under beam thermal loading in outdoor environmental conditions for two of the world's largest observatories: the 10-m Keck telescope and the Daniel K. Inouye Solar Telescope (DKIST). DKIST will produce a 300-W optical beam, which has imposed stringent requirements on the large diameter six-crystal retarders, dichroic beamsplitters, and internal optics. DKIST retarders are used in a converging beam with F/ ratios between 8 and 62. The fringe spectral periods, amplitudes, and thermal models of retarder behavior assisted DKIST optical designs and calibration plans with future application to many astronomical spectropolarimeters. The Low Resolution Imaging Spectrograph with polarimetry instrument at Keck also uses six-crystal retarders in a converging F / 13 beam in a Cassegrain focus exposed to summit environmental conditions providing observational verification of our predictions.

  11. Moeller scattering and the measurement of beta-ray longitudinal polarization

    International Nuclear Information System (INIS)

    Kliwer, J.

    1989-01-01

    Two problems that are inherent in the measurement of longitudinal polarization of beta rays via Moeller scattering (Bhabha scattering for positrons) are the low signal-to-noise ratio due to the electron-nucleon-scattered background and the small fraction of electrons that are polarized in the target. The present article shows how to optimize the signal-to-noise ratio by the collection of Moeller-scattered events using a thick-lens beta-ray spectrometer where the entrance baffle is set very narow to accommodate the relativistically contracted cone of Moeller events; this in turn minimizes the electron-nucleon-scattered background and maximizes the signal-to-noise ratio. In the case of positrons, recent studies of electron channeling in crystals suggest a target that will reduce Bhabha scattering from the large fraction of unpolarized inner-shell electrons and predominantly pick off the polarized fraction of target electrons. (orig.)

  12. Modulating emission polarization of semiconductor quantum dots through surface plasmon of metal nanorod

    Science.gov (United States)

    Cheng, Mu-Tian; Liu, Shao-Ding; Wang, Qu-Quan

    2008-04-01

    We theoretically investigated the dynamics of exciton populations [ρyy(t ) and ρxx(t )] on two orthogonal polarization eigenstates (∣x⟩ and ∣y⟩) and the polarization ratio P(t )=[ρyy(t )-ρxx(t )]/[ρyy(t )+ρxx(t )] of an anisotropic InGaAs quantum dot modulated by the surface plasmon of an Au nanorod (NR). In the resonance of longitudinal surface plasmon of AuNR, the polarization ratio P(t ) increases from 0.22 to 0.99 during the excitation due to the efficient enhancement of Rabi frequency of the transition between the ∣y⟩ and vacuum states, and decreases from 0.02 to -0.92 after the excitation pulse due to the enhancement of decay rate of the ∣y⟩ state. This offers an approach to modulate the dynamic polarization ratio of radiative emissions.

  13. RHIC FY15 pp Run RHIC and AGS polarization analysis

    Energy Technology Data Exchange (ETDEWEB)

    Huang, H. [Brookhaven National Lab. (BNL), Upton, NY (United States); Adams, P. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-02-20

    The polarization information is important for the spin physics program in Relativistic Heavy Ion Collider (RHIC). There are discrepancies between AGS and RHIC polarization measurements. First, the face value of AGS polarization is higher than RHIC ones in general. Second, the measured polarization profile (described by the profile ratio R) is stronger in AGS than in RHIC. This note analyzes the polarization data from FY15 pp run period. The results show that the differences between AGS and RHIC polarization measurements are reasonable, but the R value difference is puzzling. The difference between blue and yellow ring is worth of spin simulation to explain.

  14. Influences of poly[(styrene){sub x}-stat-(chloromethylstyrene){sub y}]s additives on dewetting behaviors of polystyrene thin films: effects of polar group ratio and film thickness

    Energy Technology Data Exchange (ETDEWEB)

    Sangjan, Suntree [Research Unit of Advanced Ceramics, Department of Materials Science, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand); Traiphol, Nisanart, E-mail: Nisanart.T@chula.ac.th [Research Unit of Advanced Ceramics, Department of Materials Science, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand); Center for Petroleum, Petrochemical, and Advanced Materials, Chulalongkorn University, Bangkok 10330 (Thailand); Traiphol, Rakchart, E-mail: Rakchartt@nu.ac.th [Laboratory of Advanced Polymers and Nanomaterials, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Naresuan University, Phitsanulok 65000 (Thailand); NANOTEC Center of Excellence at Mahidol University, Rama 6 Road, Ratchathewi, Bangkok 10400 (Thailand)

    2012-05-31

    This contribution investigates the addition of poly(styrene-stat-chloromethylstyrene (ClMS))s as dewetting inhibitors of polystyrene (PS) thin films with thicknesses ranging from 12 to 38 nm. The ClMS ratios in the copolymers are 5, 25 and 45 mol%. Atomic force microscopy and optical microscopy are utilized to follow morphological changes of blended PS/copolymer films upon annealing above their glass transition temperatures. We have found that thermal stability of the PS films is greatly improved when a small amount of the copolymers is added into the system. The polar ClMS groups provide anchoring sites with the polar SiO{sub x}/Si substrate while the styrene segments favorably interact with the PS matrix. The effectiveness of the copolymers as dewetting inhibitors is also found to increase with mole ratio of ClMS group. While the stability of PS films is systematically improved upon addition of the highly substituted copolymers, using the copolymer with relatively low ratio of ClMS group could lead to the opposite result. This class of copolymers can be utilized for improving thermal stability of ultrathin PS films. The fundamental knowledge from this study is also important for designing or selecting structure of additives used to improve the stability of polymeric thin films. - Highlights: Black-Right-Pointing-Pointer Efficient method for improving stability of polystyrene (PS) thin films. Black-Right-Pointing-Pointer Poly(styrene-stat-chloromethylstyrene)s are used as dewetting inhibitors. Black-Right-Pointing-Pointer Thermal stability of blended PS/copolymers greatly improved. Black-Right-Pointing-Pointer Effectiveness of the copolymers increases with mole ratio of chloromethylstyrene group. Black-Right-Pointing-Pointer Important results for designing materials in coating application.

  15. Blood Pressure Directed Booster Trainings Improve Intensive Care Unit Provider Retention of Excellent Cardiopulmonary Resuscitation Skills.

    Science.gov (United States)

    Wolfe, Heather; Maltese, Matthew R; Niles, Dana E; Fischman, Elizabeth; Legkobitova, Veronika; Leffelman, Jessica; Berg, Robert A; Nadkarni, Vinay M; Sutton, Robert M

    2015-11-01

    Brief, intermittent cardiopulmonary resuscitation (CPR) training sessions, "Booster Trainings," improve CPR skill acquisition and short-term retention. The objective of this study was to incorporate arterial blood pressure (ABP) tracings into Booster Trainings to improve CPR skill retention. We hypothesized that ABP-directed CPR "Booster Trainings" would improve intensive care unit (ICU) provider 3-month retention of excellent CPR skills without need for interval retraining. A CPR manikin creating a realistic relationship between chest compression depth and ABP was used for training/testing. Thirty-six ICU providers were randomized to brief, bedside ABP-directed CPR manikin skill retrainings: (1) Booster Plus (ABP visible during training and testing) versus (2) Booster Alone (ABP visible only during training, not testing) versus (3) control (testing, no intervention). Subjects completed skill tests pretraining (baseline), immediately after training (acquisition), and then retention was assessed at 12 hours, 3 and 6 months. The primary outcome was retention of excellent CPR skills at 3 months. Excellent CPR was defined as systolic blood pressure of 100 mm Hg or higher and compression rate 100 to 120 per minute. Overall, 14 of 24 (58%) participants acquired excellent CPR skills after their initial training (Booster Plus 75% vs 50% Booster Alone, P = 0.21). Adjusted for age, ABP-trained providers were 5.2× more likely to perform excellent CPR after the initial training (95% confidence interval [95% CI], 1.3-21.2; P = 0.02), and to retain these skills at 12 hours (adjusted odds ratio, 4.4; 95% CI, 1.3-14.9; P = 0.018) and 3 months (adjusted odds ratio, 4.1; 95% CI, 1.2-13.9; P = 0.023) when compared to baseline performance. The ABP-directed CPR booster trainings improved ICU provider 3-month retention of excellent CPR skills without the need for interval retraining.

  16. InN{0001} polarity by ion scattering spectroscopy

    International Nuclear Information System (INIS)

    Walker, M.; Veal, T.D.; McConville, C.F.; Lu, Hai; Schaff, W.J.

    2005-01-01

    The polarity of a wurtzite InN thin film grown on a c-plane sapphire substrate with GaN and AlN buffer layers has been investigated by co-axial impact collision ion scattering spectroscopy (CAICISS). Time of flight (TOF) spectra of He + ions scattered from the surface of the InN film were taken as a function of the incident angles of the primary 3 keV He + ions. From the TOF spectra, the polar angle-dependence of the In scattered intensity was obtained. Comparison of the experimental polar-angle dependence of the In CAICISS signal intensity with simulated results for the various volume ratios of (0001)- and (000 anti 1)-polarity domains indicated that the InN film is approximately 75% In-polarity and 25% N-polarity. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. A novel orthogonally linearly polarized Nd:YVO4 laser

    International Nuclear Information System (INIS)

    Xing-Peng, Yan; Qiang, Liu; Hai-Long, Chen; Xing, Fu; Ma-Li, Gong; Dong-Sheng, Wang

    2010-01-01

    We presented a novel orthogonally linearly polarized Nd:YVO 4 laser. Two pieces of α-cut grown-together composite YVO 4 /Nd:YVO 4 crystals were placed in the resonant cavity with the c-axis of the two crystals orthogonally. The polarization and power performance of the orthogonally polarized laser were investigated. A 26.2-W orthogonally linearly polarized laser was obtained. The power ratio between the two orthogonally polarized lasers was varied with the pump power caused by the polarized mode coupling. The longitudinal modes competition and the corresponding variable optical beats were also observed from the orthogonally polarized laser. We also adjusted the crystals with their c-axis parallele to each other, and a 40.7-W linearly polarized TEM 00 laser was obtained, and the beam quality factors were M x 2 = 1.37 and M y 2 = 1.25. (classical areas of phenomenology)

  18. Dynamic polarization of 19F in a fluorinated alcohol

    International Nuclear Information System (INIS)

    Hill, D.; Kasprzyk, T.; Jarmer, J.J.; Penttilae, S.; Krumpolc, M.; Hoffmann, G.W.; Purcell, M.

    1988-01-01

    We have studied microwave dynamic cooling of 19 F and 1 H nuclei in mixtures of 1,1,1,3,3,3-hexafluoro-2-propanol and water, doped with Cr(V) complex. Equal spin temperatures of the two nuclei are produced, and the highest spin polarizations (/approximately/80%) are found in mixtures near the eutectic ratio. The high fluorine content and polarization make this a suitable material for polarized nuclear scattering experiments. 11 refs., 3 figs., 1 tab

  19. Depolarization ratio of polar stratospheric clouds in coastal Antarctica: comparison analysis between ground-based Micro Pulse Lidar and space-borne CALIOP observations

    Directory of Open Access Journals (Sweden)

    C. Córdoba-Jabonero

    2013-03-01

    Full Text Available Polar stratospheric clouds (PSCs play an important role in polar ozone depletion, since they are involved in diverse ozone destruction processes (chlorine activation, denitrification. The degree of that ozone reduction is depending on the type of PSCs, and hence on their occurrence. Therefore PSC characterization, mainly focused on PSC-type discrimination, is widely demanded. The backscattering (R and volume linear depolarization (δV ratios are the parameters usually used in lidar measurements for PSC detection and identification. In this work, an improved version of the standard NASA/Micro Pulse Lidar (MPL-4, which includes a built-in depolarization detection module, has been used for PSC observations above the coastal Antarctic Belgrano II station (Argentina, 77.9° S 34.6° W, 256 m a.s.l. since 2009. Examination of the MPL-4 δV feature as a suitable index for PSC-type discrimination is based on the analysis of the two-channel data, i.e., the parallel (p- and perpendicular (s- polarized MPL signals. This study focuses on the comparison of coincident δV-profiles as obtained from ground-based MPL-4 measurements during three Antarctic winters with those reported from the space-borne lidar CALIOP (Cloud-Aerosol Lidar with Orthogonal Polarization aboard the CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation satellite in the same period (83 simultaneous cases are analysed for 2009–2011 austral winter times. Three different approaches are considered for the comparison analysis between both lidar profile data sets in order to test the degree of agreement: the correlation coefficient (CC, as a measure of the relationship between both PSC vertical structures; the mean differences together with their root mean square (RMS values found between data sets; and the percentage differences (BIAS, parameter also used in profiling comparisons between CALIOP and other ground-based lidar systems. All of them are examined as a function

  20. THE LINE POLARIZATION WITHIN A GIANT Lyα NEBULA

    International Nuclear Information System (INIS)

    Prescott, Moire K. M.; Smith, Paul S.; Schmidt, Gary D.; Dey, Arjun

    2011-01-01

    Recent theoretical work has suggested that Lyα nebulae could be substantially polarized in the Lyα emission line, depending on the geometry, kinematics, and powering mechanism at work. Polarization observations can therefore provide a useful constraint on the source of ionization in these systems. In this Letter, we present the first Lyα polarization measurements for a giant Lyα nebula at z∼ 2.656. We do not detect any significant linear polarization of the Lyα emission: P Lyα = 2.6% ± 2.8% (corrected for statistical bias) within a single large aperture. The current data also do not show evidence for the radial polarization gradient predicted by some theoretical models. These results rule out singly scattered Lyα (e.g., from the nearby active galactic nucleus, AGN) and may be inconsistent with some models of backscattering in a spherical outflow. However, the effects of seeing, diminished signal-to-noise ratio, and angle averaging within radial bins make it difficult to put strong constraints on the radial polarization profile. The current constraints may be consistent with higher density outflow models, spherically symmetric infall models, photoionization by star formation within the nebula or the nearby AGN, resonant scattering, or non-spherically symmetric cold accretion (i.e., along filaments). Higher signal-to-noise ratio data probing to higher spatial resolution will allow us to harness the full diagnostic power of polarization observations in distinguishing between theoretical models of giant Lyα nebulae.

  1. Polarization-Insensitive Surface Plasmon Polarization Electro-Absorption Modulator Based on Epsilon-Near-Zero Indium Tin Oxide

    Science.gov (United States)

    Jin, Lin; Wen, Long; Liang, Li; Chen, Qin; Sun, Yunfei

    2018-02-01

    CMOS-compatible plasmonic modulators operating at the telecom wavelength are significant for a variety of on-chip applications. Relying on the manipulation of the transverse magnetic (TM) mode excited on the metal-dielectric interface, most of the previous demonstrations are designed to response only for specific polarization state. In this case, it will lead to a high polarization dependent loss, when the polarization-sensitive modulator integrates to a fiber with random polarization state. Herein, we propose a plasmonic modulator utilizing a metal-oxide indium tin oxide (ITO) wrapped around the silicon waveguide and investigate its optical modulation ability for both the vertical and horizontal polarized guiding light by tuning electro-absorption of ITO with the field-induced carrier injection. The electrically biased modulator with electron accumulated at the ITO/oxide interface allows for epsilon-near-zero (ENZ) mode to be excited at the top or lateral portion of the interface depending on the polarization state of the guiding light. Because of the high localized feature of ENZ mode, efficient electro-absorption can be achieved under the "OFF" state of the device, thus leading to large extinction ratio (ER) for both polarizations in our proposed modulator. Further, the polarization-insensitive modulation is realized by properly tailoring the thickness of oxide in two different stacking directions and therefore matching the ER values for device operating at vertical and horizontal polarized modes. For the optimized geometry configuration, the difference between the ER values of two polarization modes, i.e., the ΔER, as small as 0.01 dB/μm is demonstrated and, simultaneously with coupling efficiency above 74%, is obtained for both polarizations at a wavelength of 1.55 μm. The proposed plasmonic-combined modulator has a potential application in guiding and processing of light from a fiber with a random polarization state.

  2. Integrated polarization beam splitter with relaxed fabrication tolerances.

    Science.gov (United States)

    Pérez-Galacho, D; Halir, R; Ortega-Moñux, A; Alonso-Ramos, C; Zhang, R; Runge, P; Janiak, K; Bach, H-G; Steffan, A G; Molina-Fernández, Í

    2013-06-17

    Polarization handling is a key requirement for the next generation of photonic integrated circuits (PICs). Integrated polarization beam splitters (PBS) are central elements for polarization management, but their use in PICs is hindered by poor fabrication tolerances. In this work we present a fully passive, highly fabrication tolerant polarization beam splitter, based on an asymmetrical Mach-Zehnder interferometer (MZI) with a Si/SiO(2) Periodic Layer Structure (PLS) on top of one of its arms. By engineering the birefringence of the PLS we are able to design the MZI arms so that sensitivities to the most critical fabrication errors are greatly reduced. Our PBS design tolerates waveguide width variations of 400nm maintaining a polarization extinction ratio better than 13dB in the complete C-Band.

  3. The Primordial Inflation Polarization Explorer (PIPER)

    Science.gov (United States)

    Lazear, Justin Scott; Ade, Peter A.; Benford, Dominic J.; Bennett, Charles L.; Chuss, David T.; Dotson, Jessie L.; Eimer, Joseph R.; Fixsen, Dale J.; Halpern, Mark; Hinderks, James; hide

    2014-01-01

    The Primordial Inflation Polarization ExploreR (Piper) is a balloon-borne cosmic microwave background (CMB) polarimeter designed to search for evidence of inflation by measuring the large-angular scale CMB polarization signal. Bicep2 recently reported a detection of B-mode power corresponding to the tensor-to-scalar ratio r = 0.2 on approximately 2 degree scales. If the Bicep2 signal is caused by inflationary gravitational waves (IGWs), then there should be a corresponding increase in B-mode power on angular scales larger than 18 degrees. Piper is currently the only suborbital instrument capable of fully testing and extending the Bicep2 results by measuring the B-mode power spectrum on angular scales theta ? = approximately 0.6 deg to 90 deg, covering both the reionization bump and recombination peak, with sensitivity to measure the tensor-to-scalar ratio down to r = 0.007, and four frequency bands to distinguish foregrounds. Piper will accomplish this by mapping 85% of the sky in four frequency bands (200, 270, 350, 600 GHz) over a series of 8 conventional balloon flights from the northern and southern hemispheres. The instrument has background-limited sensitivity provided by fully cryogenic (1.5 K) optics focusing the sky signal onto four 32×40-pixel arrays of time-domain multiplexed Transition-Edge Sensor (TES) bolometers held at 140 milli-Kelvin. Polarization sensitivity and systematic control are provided by front-end Variabledelay Polarization Modulators (VPMs), which rapidly modulate only the polarized sky signal at 3 Hz and allow Piper to instantaneously measure the full Stokes vector (I,Q,U,0V) for each pointing. We describe the Piper instrument and progress towards its first flight.

  4. Public awareness and self-efficacy of cardiopulmonary resuscitation in communities and outcomes of out-of-hospital cardiac arrest: A multi-level analysis.

    Science.gov (United States)

    Ro, Young Sun; Shin, Sang Do; Song, Kyoung Jun; Hong, Sung Ok; Kim, Young Taek; Lee, Dong-Woo; Cho, Sung-Il

    2016-05-01

    This study aims to test the association between capacity of cardiopulmonary resuscitation (CPR) at community level and survival after out-of-hospital cardiac arrest (OHCA). Emergency medical service (EMS)-treated OHCAs with cardiac etiology in Korea between 2012 and 2013 were analyzed, excluding cases witnessed by EMS providers. Exposure variables were five indexes of community CPR capacity: awareness of CPR (CPR-Awareness), any training experience of CPR (CPR-Any-Training), recent CPR training within the last 2 years (CPR-Recent-Training), CPR training with a manikin (CPR-Manikin-Training), and CPR self-efficacy (CPR-Self-Efficacy). All measures of capacity were calculated as aggregated values for each county level using the national Korean Community Health Survey database of 228,921 responders sampled representatively from 253 counties in 2012. Endpoints were bystander CPR (BCPR) and survival to discharge. We calculated adjusted odds ratios (AORs) per 10% increment in community CPR capacity using multi-level logistic regression models, adjusting for potential confounders at individual levels. Of 29,052 eligible OHCAs, 11,079 (38.1%) received BCPR. Patients were more likely to receive BCPR in communities with higher proportions of residents with CPR-Awareness, CPR-Any-Training, CPR-Recent-Training, CPR-Manikin-Training, and CPR-Self-Efficacy (all pCPR-Awareness, 1.10 (1.04-1.15) for CPR-Any-Training, and 1.08 (1.03-1.13) for CPR-Self-Efficacy. For survival to discharge, AORs (95% CIs) were 1.34 (1.23-1.47) per 10% increment in CPR-Awareness, 1.36 (1.20-1.54) for CPR-Any-Training, and 1.29 (1.15-1.45) for CPR-Self-Efficacy. Higher CPR capacity at community level was associated with higher bystander CPR and survival to discharge rates after OHCA. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Faraday polarization fluctuations of satellite beacon signals

    Science.gov (United States)

    Lee, M. C.; Klobuchar, J. A.

    1988-01-01

    The anisotropic effects of random density irregularities in causing Faraday polarization fluctuations of VHF radio signals are examined, taking both rod-like and sheet-like irregularities into consideration. It is found that the variance of Faraday polarization fluctuations depends on the ratio of perpendicular to parallel correlation lengths. The anisotropic effect of rod-like ionospheric irregularities are shown to be most appreciable for longitudinal propagation. The anisotropic effect of sheet-like ionospheric irregularities, however, is not strongly dependent on the radio propagation angle. During transionospheric propagation at large angles with respect to the geomagnetic field, sheet-like irregularities may cause greater Faraday polarization fluctuations than rod-like irregularities.

  6. Multiple-band reflective polarization converter using U-shaped metamaterial

    International Nuclear Information System (INIS)

    Huang, Xiaojun; Yang, Dong; Yang, Helin

    2014-01-01

    A multiple-band metamaterial reflective polarization converter (RPC) is proposed, which is composed of the dielectric substrate sandwiched with U-shaped metallic patterns and continuous metal film. The proposed U-shaped metamaterial RPC (UMM-RPC) can convert a linearly polarized wave to its cross polarized wave at the three resonant frequencies, which also can convert the linearly polarized wave to circularly polarized wave at other three resonant frequencies. Furthermore, the proposed UMM-RPC can maintain the same conversional direction at the three resonant frequencies when incident on a circularly polarized wave. The simulated and measured results are in agreement in the entire frequency range, and the polarization conversion ratio is over 90% for both linear and circular polarizations. The surface current distributions of the UMM-RPC are discussed to look into the physical mechanism. The proposed UMM-RPC has simple geometry but more operating frequency bands compared to the previous designs and can be used in applications such as antenna radome, remote sensors, and radiometer

  7. Multiple-band reflective polarization converter using U-shaped metamaterial

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiaojun [College of Physical Science and Technology, Central China Normal University, Wuhan 430079 (China); Department of Physics, Kashgar Teachers College, Kashgar 844000 (China); Yang, Dong [College of Physics and Electronics Science, Hubei Normal University, Huangshi 435002 (China); Yang, Helin, E-mail: emyang@mail.ccnu.edu.cn [College of Physical Science and Technology, Central China Normal University, Wuhan 430079 (China)

    2014-03-14

    A multiple-band metamaterial reflective polarization converter (RPC) is proposed, which is composed of the dielectric substrate sandwiched with U-shaped metallic patterns and continuous metal film. The proposed U-shaped metamaterial RPC (UMM-RPC) can convert a linearly polarized wave to its cross polarized wave at the three resonant frequencies, which also can convert the linearly polarized wave to circularly polarized wave at other three resonant frequencies. Furthermore, the proposed UMM-RPC can maintain the same conversional direction at the three resonant frequencies when incident on a circularly polarized wave. The simulated and measured results are in agreement in the entire frequency range, and the polarization conversion ratio is over 90% for both linear and circular polarizations. The surface current distributions of the UMM-RPC are discussed to look into the physical mechanism. The proposed UMM-RPC has simple geometry but more operating frequency bands compared to the previous designs and can be used in applications such as antenna radome, remote sensors, and radiometer.

  8. Intercomparison of Vertical Structure of Storms Revealed by Ground-Based (NMQ and Spaceborne Radars (CloudSat-CPR and TRMM-PR

    Directory of Open Access Journals (Sweden)

    Veronica M. Fall

    2013-01-01

    Full Text Available Spaceborne radars provide great opportunities to investigate the vertical structure of clouds and precipitation. Two typical spaceborne radars for such a study are the W-band Cloud Profiling Radar (CPR and Ku-band Precipitation Radar (PR, which are onboard NASA’s CloudSat and TRMM satellites, respectively. Compared to S-band ground-based radars, they have distinct scattering characteristics for different hydrometeors in clouds and precipitation. The combination of spaceborne and ground-based radar observations can help in the identification of hydrometeors and improve the radar-based quantitative precipitation estimation (QPE. This study analyzes the vertical structure of the 18 January, 2009 storm using data from the CloudSat CPR, TRMM PR, and a NEXRAD-based National Mosaic and Multisensor QPE (NMQ system. Microphysics above, within, and below the melting layer are studied through an intercomparison of multifrequency measurements. Hydrometeors’ type and their radar scattering characteristics are analyzed. Additionally, the study of the vertical profile of reflectivity (VPR reveals the brightband properties in the cold-season precipitation and its effect on the radar-based QPE. In all, the joint analysis of spaceborne and ground-based radar data increases the understanding of the vertical structure of storm systems and provides a good insight into the microphysical modeling for weather forecasts.

  9. Enhanced polarization of (11–22) semi-polar InGaN nanorod array structure

    Energy Technology Data Exchange (ETDEWEB)

    Athanasiou, M.; Smith, R. M.; Hou, Y.; Zhang, Y.; Gong, Y.; Wang, T., E-mail: t.wang@sheffield.ac.uk [Department of Electronic and Electrical Engineering, University of Sheffield, Mappin Street, Sheffield S1 3JD (United Kingdom)

    2015-10-05

    By means of a cost effective nanosphere lithography technique, an InGaN/GaN multiple quantum well structure grown on (11–22) semipolar GaN has been fabricated into two dimensional nanorod arrays which form a photonic crystal (PhC) structure. Such a PhC structure demonstrates not only significantly increased emission intensity, but also an enhanced polarization ratio of the emission. This is due to an effective inhibition of the emission in slab modes and then redistribution to the vertical direction, thus minimizing the light scattering processes that lead to randomizing of the optical polarization. The PhC structure is designed based on a standard finite-difference-time-domain simulation, and then optically confirmed by detailed time-resolved photoluminescence measurements. The results presented pave the way for the fabrication of semipolar InGaN/GaN based emitters with both high efficiency and highly polarized emission.

  10. Enhanced polarization of (11–22) semi-polar InGaN nanorod array structure

    International Nuclear Information System (INIS)

    Athanasiou, M.; Smith, R. M.; Hou, Y.; Zhang, Y.; Gong, Y.; Wang, T.

    2015-01-01

    By means of a cost effective nanosphere lithography technique, an InGaN/GaN multiple quantum well structure grown on (11–22) semipolar GaN has been fabricated into two dimensional nanorod arrays which form a photonic crystal (PhC) structure. Such a PhC structure demonstrates not only significantly increased emission intensity, but also an enhanced polarization ratio of the emission. This is due to an effective inhibition of the emission in slab modes and then redistribution to the vertical direction, thus minimizing the light scattering processes that lead to randomizing of the optical polarization. The PhC structure is designed based on a standard finite-difference-time-domain simulation, and then optically confirmed by detailed time-resolved photoluminescence measurements. The results presented pave the way for the fabrication of semipolar InGaN/GaN based emitters with both high efficiency and highly polarized emission

  11. New materials research for high spin polarized current

    International Nuclear Information System (INIS)

    Tezuka, Nobuki

    2012-01-01

    The author reports here a thorough investigation of structural and magnetic properties of Co 2 FeAl 0.5 Si 0.5 Heusler alloy films, and the tunnel magnetoresistance effect for junctions with Co 2 FeAl 0.5 Si 0.5 electrodes, spin injection into GaAs semiconductor from Co 2 FeAl 0.5 Si 0.5 , and spin filtering phenomena for junctions with CoFe 2 O 4 ferrite barrier. It was observed that tunnel magnetoresistance ratio up to 832%(386%) at 9 K (room temperature), which corresponds to the tunnel spin polarization of 0.90 (0.81) for the junctions using Co 2 FeAl 0.5 Si 0.5 Heusler electrodes by optimizing the fabrication condition. It was also found that the tunnel magnetoresistance ratio are almost the same between the junctions with Co 2 FeAl 0.5 Si 0.5 Heusler electrodes on Cr buffered (1 0 0) and (1 1 0) MgO substrates, which indicates that tunnel spin polarization of Co 2 FeAl 0.5 Si 0.5 for these two direction are almost the same. The next part of this paper is a spin filtering effect using a Co ferrite. The spin filtering effect was observed through a thin Co-ferrite barrier. The inverse type tunnel magnetoresistance ratio of −124% measured at 10 K was obtained. The inverse type magnetoresistance suggests the negative spin polarization of Co-ferrite barrier. The magnetoresistance ratio of −124% corresponds to the spin polarization of −0.77 by the Co-ferrite barrier. The last part is devoted to the spin injection from Co 2 FeAl 0.5 Si 0.5 into GaAs. The spin injection signal was clearly obtained by three terminal Hanle measurement. The spin relaxation time was estimated to be 380 ps measured at 5 K.

  12. First physical volcanological description of a Miocene, silicic, phreatomagmatic fall complex in the Carpatho-Pannonian Region (CPR)

    Science.gov (United States)

    Biró, Tamás; Hencz, Mátyás; Karátson, Dávid; Márton, Emő; Bradák-Hayashi, Balázs; Szalai, Zoltán

    2017-04-01

    The study reports the basic physical volcanological and stratigraphical features of a hitherto unrecognized silicic phreatomagmatic fall succession from the Bükk Foreland Volcanic Area (Hungary), known as part of the extensive Miocene ignimbrite volcanism of the northern CPR. The complex have been identified at two sites, in the vicinity of Bogács and Tibolddaróc villages. Tens of mm to several dm thick layers make up the 20 m thick entire succession. The complex could be subdivided into three eruption cycles by two, intercalated well-developed paleosoil horizons, which indicate longer repose periods. The eruption cycles consist of several individual eruptive events. The volcano-sedimentological field approach was completed by granulometrical and low field anisotropy of magnetic susceptibility (AMS) studies. Combined dry sieving and laser diffraction particle size analysis were performed to get information on median grain size (MdΦ) and sorting (σΦ) of friable layers. AMS was used to infer the emplacement processes. Based on the following features the succession is proposed to record a large-scale, silicic, phreatomagmatic fall activity: i) Presence of very fine ash and abundant ash aggregates, ii) General poor sorting, and often bimodal grain-size distributions; ii) Extremely weak magnetic fabric compared to dilute, thin pyroclastic density current deposits. On the basis of comparison of the recorded grain size characteristics with data from other silicic phretomagmatic fall deposits worldwide, several units in the succession can be considered as phreatoplinian fall deposit (sensu lato), described for the first time in the CPR.

  13. Highly stable polarization independent Mach-Zehnder interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Mičuda, Michal, E-mail: micuda@optics.upol.cz; Doláková, Ester; Straka, Ivo; Miková, Martina; Dušek, Miloslav; Fiurášek, Jaromír; Ježek, Miroslav, E-mail: jezek@optics.upol.cz [Department of Optics, Faculty of Science, Palacký University, 17. listopadu 1192/12, 77146 Olomouc (Czech Republic)

    2014-08-15

    We experimentally demonstrate optical Mach-Zehnder interferometer utilizing displaced Sagnac configuration to enhance its phase stability. The interferometer with footprint of 27×40 cm offers individually accessible paths and shows phase deviation less than 0.4° during a 250 s long measurement. The phase drift, evaluated by means of Allan deviation, stays below 3° or 7 nm for 1.5 h without any active stabilization. The polarization insensitive design is verified by measuring interference visibility as a function of input polarization. For both interferometer's output ports and all tested polarization states the visibility stays above 93%. The discrepancy in visibility for horizontal and vertical polarization about 3.5% is caused mainly by undesired polarization dependence of splitting ratio of the beam splitter used. The presented interferometer device is suitable for quantum-information and other sensitive applications where active stabilization is complicated and common-mode interferometer is not an option as both the interferometer arms have to be accessible individually.

  14. An efficient source of continuous variable polarization entanglement

    DEFF Research Database (Denmark)

    Dong, R.; Heersink, J.; Yoshikawa, J.-I.

    2007-01-01

    classical excitation in Ŝ3. Polarization entanglement was generated by interfering two independent polarization squeezed fields on a symmetric beam splitter. The resultant beams exhibit strong quantum noise correlations in the dark Ŝ1-Ŝ2 polarization plane. To verify entanglement generation, we......We have experimentally demonstrated the efficient creation of highly entangled bipartite continuous variable polarization states. Exploiting an optimized scheme for the production of squeezing using the Kerr non-linearity of a glass fibre we generated polarization squeezed pulses with a mean...... was found to depend critically on the beam-splitting ratio of the entangling beam splitter. Carrying out measurements on a different set of conjugate Stokes parameters, correlations of -3.6 ±0.3 and -3.4 ±0.3 dB have been observed. This result is more robust against asymmetries in the entangling beam...

  15. Polarization images of the inner regions of Comet Halley

    International Nuclear Information System (INIS)

    Eaton, N.; Scarrott, S.M.; Warren-Smith, R.F.

    1988-01-01

    The present CCD polarimeter images of intensity and polarization within the near-nucleus regions of Comet Halley show the occurrence of dust jets on two days in January, 1986, which exhibit increased polarizations above the level of the surrounding coma. Three possible reasons for the enhanced polarization in the jets are considered, assuming that the polarization increase is due to dust grains: (1) the size distribution of the grains could be different from the surrounding coma; (2) the material of the grains could have a different refractive index; and (3) the ratio of dust to gas emission could be different in the jets. 13 references

  16. Magnetoresistance through spin-polarized p states

    International Nuclear Information System (INIS)

    Papanikolaou, Nikos

    2003-01-01

    We present a theoretical study of the ballistic magnetoresistance in Ni contacts using first-principles, atomistic, electronic structure calculations. In particular we investigate the role of defects in the contact region with the aim of explaining the recently observed spectacular magnetoresistance ratio. Our results predict that the possible presence of spin-polarized oxygen in the contact region could explain conductance changes by an order of magnitude. Electronic transport essentially occurs through spin-polarized oxygen p states, and this mechanism gives a much higher magnetoresistance than that obtained assuming clean atomically sharp domain walls alone

  17. Detailed analysis of evolution of the state of polarization in all-fiber polarization transformers.

    Science.gov (United States)

    Zhu, Xiushan; Jain, Ravinder K

    2006-10-30

    We present a detailed analysis of key attributes and performance characteristics of controllably-spun birefringent-fiber-based all-fiber waveplates or "all fiber polarization transformers" (AFPTs), first proposed and demonstrated by Huang [11]; these AFPTs consist essentially of a long carefully-designed "spin-twisted" high-birefringence fiber, fabricated by slowly varying the spin rate of a birefringent fiber preform (either from very fast to very slow or vice versa) while the fiber is being drawn. The evolution of the eigenstate from a linear polarization state to a circular polarization state, induced by slow variation of the intrinsic structure from linear anisotropy at the unspun end to circular anisotropy at the fast-spun end, enables the AFPT to behave like an all-fiber quarter-wave plate independent of the wavelength of operation. Power coupling between local eigenstates causes unique evolution of the polarization state along the fiber, and has been studied to gain insight into - as well as to understand detailed characteristics of -- the polarization transformation behavior. This has been graphically illustrated via plots of the relative power in these local eigenstates as a function of distance along the length of the fiber and plots of the extinction ratio of the output state of polarization (SOP) as a function of distance and the normalized spin rate. Deeper understanding of such polarization transformers has been further elucidated by quantitative calculations related to two crucial requirements for fabricating practical AFPT devices. Our calculations have also indicated that the polarization mode dispersion behaviour of the AFPT is much smaller than that of the original birefringent fiber. Finally, a specific AFPT was experimentally investigated at two widely-separated wavelengths (1310 nm and 1550 nm) of interest in telecommunications systems applications, further demonstrating and elucidating the broadband character of such AFPTs.

  18. Integrated Cu-based TM-pass polarizer using CMOS technology platform

    KAUST Repository

    Ng, Tien Khee

    2010-01-01

    A transverse-magnetic-pass (TM-pass) copper (Cu) polarizer is proposed and analyzed using the previously published two-dimensional Method-of-Lines beam-propagation model. The proposed polarizer exhibits a simulated high-pass filter characteristics, with TM0 and TE0 mode transmissivity of >70% and <5%, respectively, in the wavelength regime of 1.2-1.6 μm. The polarization extinction ratio (PER) given by 10 log10 (PTM0)/(PTE0) is +11.5 dB across the high-pass wavelength regime. To the best of the authors\\' knowledge, we report here the smallest footprint CMOS-platform compatible TM-polarizer.

  19. Analysis on Coupled Vibration of a Radially Polarized Piezoelectric Cylindrical Transducer

    Directory of Open Access Journals (Sweden)

    Jie Xu

    2017-12-01

    Full Text Available Coupled vibration of a radially polarized piezoelectric cylindrical transducer is analyzed with the mechanical coupling coefficient method. The method has been utilized to analyze the metal cylindrical transducer and the axially polarized piezoelectric cylindrical transducer. In this method, the mechanical coupling coefficient is introduced and defined as the stress ratio in different directions. Coupled vibration of the cylindrical transducer is regarded as the interaction of the plane radial vibration of a ring and the longitudinal vibration of a tube. For the radially polarized piezoelectric cylindrical transducer, the radial and longitudinal electric admittances as functions of mechanical coupling coefficients and angular frequencies are derived, respectively. The resonance frequency equations are obtained. The dependence of resonance frequency and mechanical coupling coefficient on aspect ratio is studied. Vibrational distributions on the surfaces of the cylindrical transducer are presented with experimental measurement. On the support of experiments, this work is verified and provides a theoretical foundation for the analysis and design of the radially polarized piezoelectric cylindrical transducer.

  20. Broadband silicon polarization beam splitter with a high extinction ratio using a triple-bent-waveguide directional coupler.

    Science.gov (United States)

    Ong, Jun Rong; Ang, Thomas Y L; Sahin, Ezgi; Pawlina, Bryan; Chen, G F R; Tan, D T H; Lim, Soon Thor; Png, Ching Eng

    2017-11-01

    We report on the design and experimental demonstration of a broadband silicon polarization beam splitter (PBS) with a high extinction ratio (ER)≥30  dB. This was achieved using triple-bent-waveguide directional coupling in a single PBS, and cascaded PBS topology. For the single PBS, the bandwidths for an ER≥30  dB are 20 nm for the quasi-TE mode, and 70 nm for the quasi-TM mode when a broadband light source (1520-1610 nm) was employed. The insertion loss (IL) varies from 0.2 to 1 dB for the quasi-TE mode and 0.2-2 dB for the quasi-TM mode. The cascaded PBS improved the bandwidth of the quasi-TE mode for an ER≥30  dB to 90 nm, with a low IL of 0.2-2 dB. To the best of our knowledge, our PBS system is one of the best broadband PBSs with an ER as high as ∼42  dB and a low IL below 1 dB around the central wavelength, and experimentally demonstrated using edge-coupling.

  1. Analysis of CMOS Compatible Cu-Based TM-Pass Optical Polarizer

    KAUST Repository

    Ng, Tien Khee

    2012-02-10

    A transverse-magnetic-pass (TM-pass) optical polarizer based on Cu complementary metal-oxide-semiconductor technology platform is proposed and analyzed using the 2-D method-of-lines numerical model. In designing the optimum configuration for the polarizer, it was found that the metal-insulator-metal (MIM) polarizer structure is superior compared to the insulator-metal-insulator polarizer structure due to its higher polarization extinction ratio (PER) and low insertion loss. An optimized MIM TM-pass polarizer exhibits simulated long wavelength pass filter characteristics of > ?1.2 ?m, with fundamental TM 0 and TE 0 mode transmissivity of >70% and <5%, respectively, and with PER ?11.5 dB in the wavelength range of 1.2-1.6 ?m. The subwavelength and submicrometer features of this TM-polarizer are potentially suitable for compact and low power photonics integrated circuit implementation on silicon-based substrates. © 1989-2012 IEEE.

  2. Polarization diversity DPSK demodulator on the silicon-on-insulator platform with simple fabrication

    DEFF Research Database (Denmark)

    Ding, Yunhong; Huang, Bo; Ou, Haiyan

    2013-01-01

    of a tapered waveguide followed by a 2 × 2 multimode interferometer. A lowest insertion loss of 0.5 dB with low polarization dependent loss of 1.6 dB and low polarization dependent extinction ratio smaller than 3 dB are measured for the polarization diversity circuit. Clear eye-diagrams and a finite power...

  3. An audiovisual feedback device for compression depth, rate and complete chest recoil can improve the CPR performance of lay persons during self-training on a manikin

    International Nuclear Information System (INIS)

    Krasteva, Vessela; Jekova, Irena; Didon, Jean-Philippe

    2011-01-01

    This study aims to contribute to the scarce data available about the abilities of untrained lay persons to perform hands-only cardio-pulmonary resuscitation (CPR) on a manikin and the improvement of their skills during training with an autonomous CPR feedback device. The study focuses on the following questions: (i) Is there a need for such a CPR training device? (ii) How adequate are the embedded visual feedback and audio guidance for training of lay persons who learn and correct themselves in real time without instructor guidance? (iii) What is the achieved effect of only 3 min of training? This is a prospective study in which 63 lay persons (volunteers) received a debriefing to basic life support and then performed two consecutive 3 min trials of hands-only CPR on a manikin. The pre-training skills of the lay persons were tested in trial 1. The training process with audio guidance and visual feedback from a cardio compression control device (CC-Device) was recorded in trial 2. After initial debriefing for correct chest compressions (CC) with rate 85–115 min −1 , depth 3.8–5.4 cm and complete recoil, in trial 1 the lay persons were able to perform CC without feedback at mean rate 95.9 ± 18.9 min −1 , mean depth 4.13 ± 1.5 cm, with low proportions of 'correct depth', 'correct rate' and 'correct recoil' at 33%, 43%, 87%, resulting in the scarce proportion of 14% for compressions, which simultaneously fulfill the three quality criteria ('correct all'). In trial 2, the training process by the CC-Device was established by the significant improvement of the CC skills until the 60th second of training, when 'correct depth', 'correct rate' and 'correct recoil' attained the plateau of the highest quality at 82%, 90%, 96%, respectively, resulting in 73% 'correct all' compressions within 3 min of training. The training was associated with reduced variance of the mean rate 102.4 ± 4

  4. A variable partially polarizing beam splitter

    Science.gov (United States)

    Flórez, Jefferson; Carlson, Nathan J.; Nacke, Codey H.; Giner, Lambert; Lundeen, Jeff S.

    2018-02-01

    We present designs for variably polarizing beam splitters. These are beam splitters allowing the complete and independent control of the horizontal and vertical polarization splitting ratios. They have quantum optics and quantum information applications, such as quantum logic gates for quantum computing and non-local measurements for quantum state estimation. At the heart of each design is an interferometer. We experimentally demonstrate one particular implementation, a displaced Sagnac interferometer configuration, that provides an inherent instability to air currents and vibrations. Furthermore, this design does not require any custom-made optics but only common components which can be easily found in an optics laboratory.

  5. Polarization behaviour of polyvinylidenefluoride-polysulfone (PVDF: PSF) blends under high field and high temperature condition

    Science.gov (United States)

    Shrivas, Sandhya; Patel, Swarnim; Dubey, R. K.; Keller, J. M.

    2018-05-01

    Thermally stimulated discharge currents of PVDF: PSF blend samples in ratio 80:20 and 95:05 prepared by the solution cast technique have been studied as a function of polarizing field and polarizing temperature, the temperature corresponding to a peak in TSDC is found to be independent of polarizing field but dependent on the polarizing temperature.

  6. Polarization characteristics of double-clad elliptical fibers.

    Science.gov (United States)

    Zhang, F; Lit, J W

    1990-12-20

    A scalar variational analysis based on a Gaussian approximation of the fundamental mode of a double-clad elliptical fiber with a depressed inner cladding is studied. The polarization properties and graphic results are presented; they are given in terms of three parameters: the ratio of the major axis to the minor axis of the core, the ratio of the inner cladding major axis to the core major axis, and the difference between the core index and the inner cladding index. The variations of both the spot size and the field intensity with core ellipticity are examined. It is shown that high birefringence and dispersion-free orthogonal polarization modes can be obtained within the single-mode region and that the field intensity distribution may be more confined to the fiber center than in a single-clad elliptical fiber.

  7. Performance of wireless optical communication systems under polarization effects over atmospheric turbulence

    Science.gov (United States)

    Zhang, Jiankun; Li, Ziyang; Dang, Anhong

    2018-06-01

    It has been recntly shown that polarization state of propagation beam would suffer from polarization fluctuations due to the detrimental effects of atmospheric turbulence. This paper studies the performance of wireless optical communication (WOC) systems in the presence of polarization effect of atmosphere. We categorize the atmospheric polarization effect into polarization rotation, polarization-dependent power loss, and phase shift effect, with each effect described and modeled with the help of polarization-coherence theory and the extended Huygens-Fresnelprinciple. The channel matrices are derived to measure the cross-polarization interference of the system. Signal-to-noise ratio and bit error rate for polarization multiplexing system and polarization modulation system are obtained to assess the viability using the approach of M turbulence model. Monte Carlo simulation results show the performance of polarization based WOC systems to be degraded by atmospheric polarization effect, which could be evaluated precisely using the proposed model with given turbulent strengths.

  8. Axisymmetric magnetohydrodynamic equilibria in local polar coordinates

    International Nuclear Information System (INIS)

    Clemente, R.A.

    1982-01-01

    The Grad--Shafranov equation for an ideal magnetohydrodynamic axisymmetric toroidal configuration is solved analytically in a local polar coordinate system using a novel method which produces solutions valid up to the second order in the inverse aspect ratio expansion

  9. Polarization measurement for internal polarized gaseous targets

    International Nuclear Information System (INIS)

    Ye Zhenyu; Ye Yunxiu; Lv Haijiang; Mao Yajun

    2004-01-01

    The authors present an introduction to internal polarized gaseous targets, polarization method, polarization measurement method and procedure. To get the total nuclear polarization of hydrogen atoms (including the polarization of the recombined hydrogen molecules) in the target cell, authors have measured the parameters relating to atomic polarization and polarized hydrogen atoms and molecules. The total polarization of the target during our measurement is P T =0.853 ± 0.036. (authors)

  10. General multimode polarization splitter design in uniaxial media

    Science.gov (United States)

    Teixeira, Poliane A.; Silva, Daniely G.; Gabrielli, Lucas H.; Spadoti, Danilo H.; Junqueira, Mateus A. F. C.

    2018-03-01

    Quasiconformal transformation optics is used to design two-dimensional polarization beam splitters. The resulting media present inhomogeneous uniaxial permittivity and nonmagnetic response. The compact devices are theoretically designed and investigated for symmetrical and asymmetrical geometries, with footprint of 64 and 110 μm2, respectively. The polarization splitter performance is evaluated for the fundamental mode and third mode, exhibiting an insertion loss closer to 0 dB and extinction ratio above 40 dB over a broad wavelength range.

  11. Comparison of different techniques for in microgravity-a simple mathematic estimation of cardiopulmonary resuscitation quality for space environment.

    Science.gov (United States)

    Braunecker, S; Douglas, B; Hinkelbein, J

    2015-07-01

    Since astronauts are selected carefully, are usually young, and are intensively observed before and during training, relevant medical problems are rare. Nevertheless, there is a certain risk for a cardiac arrest in space requiring cardiopulmonary resuscitation (CPR). Up to now, there are 5 known techniques to perform CPR in microgravity. The aim of the present study was to analyze different techniques for CPR during microgravity about quality of CPR. To identify relevant publications on CPR quality in microgravity, a systematic analysis with defined searching criteria was performed in the PubMed database (http://www.pubmed.com). For analysis, the keywords ("reanimation" or "CPR" or "resuscitation") and ("space" or "microgravity" or "weightlessness") and the specific names of the techniques ("Standard-technique" or "Straddling-manoeuvre" or "Reverse-bear-hug-technique" or "Evetts-Russomano-technique" or "Hand-stand-technique") were used. To compare quality and effectiveness of different techniques, we used the compression product (CP), a mathematical estimation for cardiac output. Using the predefined keywords for literature search, 4 different publications were identified (parabolic flight or under simulated conditions on earth) dealing with CPR efforts in microgravity and giving specific numbers. No study was performed under real-space conditions. Regarding compression depth, the handstand (HS) technique as well as the reverse bear hug (RBH) technique met parameters of the guidelines for CPR in 1G environments best (HS ratio, 0.91 ± 0.07; RBH ratio, 0.82 ± 0.13). Concerning compression rate, 4 of 5 techniques reached the required compression rate (ratio: HS, 1.08 ± 0.11; Evetts-Russomano [ER], 1.01 ± 0.06; standard side straddle, 1.00 ± 0.03; and straddling maneuver, 1.03 ± 0.12). The RBH method did not meet the required criteria (0.89 ± 0.09). The HS method showed the highest cardiac output (69.3% above the required CP), followed by the ER technique (33

  12. Unidirectional cross polarization rotator with enhanced broadband transparency by cascading twisted nanobars

    International Nuclear Information System (INIS)

    Wang, Ying-Hua; Shao, Jian; Li, Jie; Zhu, Ming-Jie; Li, Jiaqi; Dong, Zheng-Gao

    2016-01-01

    We demonstrate the optical activity for linear polarization by twisting cascading multilayer nanobars, for which the x- (y-)polarized light is significantly transformed to a y- (x-)polarized one with enhanced transmittance in a unidirectional manner, and the bandwidth can be broadened by increasing the cascading number of layers. The polarization conversion rate reaches nearly 100% with a maximum cross-polarization transmission coefficient larger than 0.95. This phenomenon is attributed to the chiral structural arrangement and anisotropic resonance of nanobars, which consequently leads to different cross-polarization conversions between forward and backward incident lights, and thus the unidirectional transmission with an extinction ratio up to 10 3 . These characteristics show application potential in optical nano-devices. (paper)

  13. Robust reflective ghost imaging against different partially polarized thermal light

    Science.gov (United States)

    Li, Hong-Guo; Wang, Yan; Zhang, Rui-Xue; Zhang, De-Jian; Liu, Hong-Chao; Li, Zong-Guo; Xiong, Jun

    2018-03-01

    We theoretically study the influence of degree of polarization (DOP) of thermal light on the contrast-to-noise ratio (CNR) of the reflective ghost imaging (RGI), which is a novel and indirect imaging modality. An expression for the CNR of RGI with partially polarized thermal light is carefully derived, which suggests a weak dependence of CNR on the DOP, especially when the ratio of the object size to the speckle size of thermal light has a large value. Different from conventional imaging approaches, our work reveals that RGI is much more robust against the DOP of the light source, which thereby has advantages in practical applications, such as remote sensing.

  14. Investigation of oxyhemoglobin and carboxyhemoglobin ratios in right and left cardiac blood for diagnosis of fatal hypothermia and death by fire.

    Science.gov (United States)

    Kanto-Nishimaki, Yuko; Saito, Haruka; Watanabe-Aoyagi, Miwako; Toda, Ritsuko; Iwadate, Kimiharu

    2014-11-01

    Few large-scale investigations have looked at the oxyhemoglobin ratio (%O2-Hb) or the carboxyhemoglobin ratio (%CO-Hb) in fatal hypothermia and death by fire as applicable to forensic medicine. We therefore retrospectively examined right and left cardiac blood samples for both %O2-Hb and %CO-Hb in 690 forensic autopsy cases. We therefore sought to establish reference values for the above forensic diagnoses, to compare %O2-Hb in fatal hypothermia with or without cardiopulmonary resuscitation (CPR), and to compare the relationship between %CO-Hb and smoking history. All %O2-Hb and %CO-Hb data were obtained during or immediately after autopsies using a portable CO-oximeter. Death by carbon monoxide (CO) intoxication and death by fire were excluded from the analysis involving smoking history. In fatal hypothermia, %O2-Hb in the left cardiac blood was significantly higher than that in the right cardiac blood, providing important evidence for fatal hypothermia. Furthermore, %O2-Hb in the left cardiac blood increases with CPR but that in the right cardiac blood increases in parallel. No correlation was observed between rectal temperature and %O2-Hb in the right and left cardiac blood, indicating that it is unlikely that postmortem cooling increases %O2-Hb in cardiac blood. %CO-Hb in smokers was significantly higher than that in non-smokers, although the number of cigarettes smoked did not appear to be significant. When assessing death by fire, we identified that %CO-Hb of >10% was a reliable marker of antemortem CO inhalation, regardless of smoking history. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. The isotopic composition of methane in polar ice cores

    Science.gov (United States)

    Craig, H.; Chou, C. C.; Welhan, J. A.; Stevens, C. M.; Engelkemeir, A.

    1988-01-01

    Air bubbles in polar ice cores indicate that about 300 years ago the atmospheric mixing ratio of methane began to increase rapidly. Today the mixing ratio is about 1.7 parts per million by volume, and, having doubled once in the past several hundred years, it will double again in the next 60 years if current rates continue. Carbon isotope ratios in methane up to 350 years in age have been measured with as little as 25 kilograms of polar ice recovered in 4-meter-long ice-core segments. The data show that: (1) in situ microbiology or chemistry has not altered the ice-core methane concentrations, and (2) that the carbon-13 to carbon-12 ratio of atmospheric CH4 in ice from 100 years and 300 years ago was about 2 per mil lower than at present. Atmospheric methane has a rich spectrum of isotopic sources: the ice-core data indicate that anthropogenic burning of the earth's biomass is the principal cause of the recent C-13H4 enrichment, although other factors may also contribute.

  16. Anodic polarization of carbon graphite electrodes in chloride fluoride melts zirconium containing

    International Nuclear Information System (INIS)

    Lyapustin, A.A.; Kanashin, Yu.P.; Nichkov, I.F.; Smyshlyaev, V.Yu.

    1985-01-01

    Polarization of carbon graphite anodes in zircorium containing chloride fluoride melts of the KCl-K 2 ZrF 6 -KF composition at molar ratios [F]:[Zr] being equal to 6, 12, 18, 24, 30 has been studied. K 2 ZrF 6 concentration constitutes 25; 18.9; 15.2; 12.7; 11.8% (by mass), correspondingly. Vitreous carbon (VC-2500), high purity graphite and graphite EhG-0 have been used as anodic materials. Anodic polarization curves have been obtained under electrotype steady-state conditions at 973, 1023, 1073 K. Influence of concentration of fluorine ions in melt on polarization of carbon graphite anodes is shown. Content growth of fluorine ions in melt leads to shift of steady-state anode potentials to their negative values regardless a graphite mark. The most con siderable potential shift on 0.5 V takes plase at molar ratio [F]:[Zr] increasing from 6 to 12. Temperature increase, as measurements showed, doesn't influence greatly on polarization curve shape

  17. Impact of reionization on CMB polarization tests of slow-roll inflation

    International Nuclear Information System (INIS)

    Mortonson, Michael J.; Hu, Wayne

    2008-01-01

    Estimates of inflationary parameters from the CMB B-mode polarization spectrum on the largest scales depend on knowledge of the reionization history, especially at low tensor-to-scalar ratio. Assuming an incorrect reionization history in the analysis of such polarization data can strongly bias the inflationary parameters. One consequence is that the single-field slow-roll consistency relation between the tensor-to-scalar ratio and tensor tilt might be excluded with high significance even if this relation holds in reality. We explain the origin of the bias and present case studies with various tensor amplitudes and noise characteristics. A more model-independent approach can account for uncertainties about reionization, and we show that parametrizing the reionization history by a set of its principal components with respect to E-mode polarization removes the bias in inflationary parameter measurement with little degradation in precision

  18. Spin Flipping and Polarization Lifetimes of a 270 MeV Deuteron Beam

    International Nuclear Information System (INIS)

    Morozov, V.S.; Crawford, M.Q.; Etienne, Z.B.; Kandes, M.C.; Krisch, A.D.; Leonova, M.A.; Sivers, D.W.; Wong, V.K.; Yonehara, K.; Anferov, V.A.; Meyer, H.O.; Schwandt, P.; Stephenson, E.J.; Przewoski, B. von

    2003-01-01

    We recently studied the spin flipping of a 270 MeV vertically polarized deuteron beam stored in the IUCF Cooler Ring. We swept an rf solenoid's frequency through an rf-induced spin resonance and observed the effect on the beam's vector and tensor polarizations. After optimizing the resonance crossing rate and setting the solenoid's voltage to its maximum value, we obtained a spin-flip efficiency of about 94 ± 1% for the vector polarization; we also observed a partial spin-flip of the tensor polarization. We then used the rf-induced resonance to measure the vector and tensor polarizations' lifetimes at different distances from the resonance; the polarization lifetime ratio τvector/τtensor was about 1.9 ± 0.4

  19. Assessment of CPR-D skills of nurses in Göteborg, Sweden and Espoo, Finland: teaching leadership makes a difference.

    Science.gov (United States)

    Mäkinen, M; Aune, S; Niemi-Murola, L; Herlitz, J; Varpula, T; Nurmi, J; Axelsson, A B; Thorén, A-B; Castrén, M

    2007-02-01

    Construction of an effective in-hospital resuscitation programme is challenging. To document and analyse resuscitation skills assessment must provide reliable data. Benchmarking with a hospital having documented excellent results of in-hospital resuscitation is beneficial. The purpose of this study was to assess the resuscitation skills to facilitate construction of an educational programme. Nurses working in a university hospital Jorvi, Espoo (n=110), Finland and Sahlgrenska University Hospital, Göteborg (n=40), Sweden were compared. The nurses were trained in the same way in both hospitals except for the defining and teaching of leadership applied in Sahlgrenska. Jorvi nurses are not trained to be, nor do they act as, leaders in a resuscitation situation. Their cardiopulmonary resuscitation (CPR) skills using an automated external defibrillator (AED) were assessed using Objective Structured Clinical Examination (OSCE) which was build up as a case of cardiac arrest with ventricular fibrillation (VF) as the initial rhythm. The subjects were tested in pairs, each pair alone. Group-working skills were registered. All Sahlgrenska nurses, but only 49% of Jorvi nurses, were able to defibrillate. Seventy percent of the nurses working in the Sahlgrenska hospital (mean score 35/49) and 27% of the nurses in Jorvi (mean score 26/49) would have passed the OSCE test. Statistically significant differences were found in activating the alarm (Pskills of Sahlgrenska nurses were also significantly better than those of Jorvi nurses. Assessment of CPR-D skills gave valuable information for further education in both hospitals. Defining and teaching leadership seems to improve resuscitation performance.

  20. Laser microprocessing of steel with radially and azimuthally polarized femtosecond vortex pulses

    International Nuclear Information System (INIS)

    Allegre, O J; Perrie, W; Edwardson, S P; Dearden, G; Watkins, K G

    2012-01-01

    The use of a liquid-crystal spatial light modulator (SLM) device to convert a linearly polarized femtosecond laser beam into a radially or azimuthally polarized vortex beam is demonstrated. In order to verify the state of polarization at the focal plane, laser induced periodic surface structures (LIPSS) are produced on stainless steel, imprinting the complex vectorial polarization structures and confirming the efficacy of the SLM in producing the desired polarization modes. Stainless steel plates of various thicknesses are micromachined with the radially and azimuthally polarized vortex beams and the resulting cut-outs are analysed. The process efficiency and quality of each mode are compared with those of circular polarization. Radial polarization is confirmed to be the most efficient mode for machining high-aspect-ratio (depth/width > 3) channels thanks to its relatively higher absorptivity. Following our microprocessing tests, liquid-crystal SLMs emerged as a flexible off-the-shelf tool for producing radially and azimuthally polarized beams in existing ultrashort-pulse laser microprocessing systems. (paper)

  1. Achieving highly efficient and broad-angle polarization beam filtering using epsilon-near-zero metamaterials mimicked by metal-dielectric multilayers

    Science.gov (United States)

    Wu, Feng

    2018-03-01

    We report a highly efficient and broad-angle polarization beam filter at visible wavelengths using an anisotropic epsilon-near-zero metamaterial mimicked by a multilayer composed of alternative subwavelength magnesium fluoride and silver layers. The underlying physics can be explained by the dramatic difference between two orthogonal polarizations' iso-frequency curves of anisotropic epsilon-near-zero metamaterials. Transmittance for two orthogonal polarization waves and the polarization extinction ratio are calculated via the transfer matrix method to assess the comprehensive performance of the proposed polarization beam filter. From the simulation results, the proposed polarization beam filter is highly efficient (the polarization extinction ratio is far larger than two orders of magnitude) and has a broad operating angle range (ranging from 30° to 75°). Finally, we show that the proper tailoring of the periodic number enables us to obtain high comprehensive performance of the proposed polarization beam filter.

  2. N-polar GaN epitaxy and high electron mobility transistors

    International Nuclear Information System (INIS)

    Wong, Man Hoi; Keller, Stacia; Dasgupta, Nidhi Sansaptak; Denninghoff, Daniel J; Kolluri, Seshadri; Brown, David F; Lu, Jing; Fichtenbaum, Nicholas A; Ahmadi, Elaheh; DenBaars, Steven P; Speck, James S; Mishra, Umesh K; Singisetti, Uttam; Chini, Alessandro; Rajan, Siddharth

    2013-01-01

    This paper reviews the progress of N-polar (0001-bar) GaN high frequency electronics that aims at addressing the device scaling challenges faced by GaN high electron mobility transistors (HEMTs) for radio-frequency and mixed-signal applications. Device quality (Al, In, Ga)N materials for N-polar heterostructures are developed using molecular beam epitaxy and metalorganic chemical vapor deposition. The principles of polarization engineering for designing N-polar HEMT structures will be outlined. The performance, scaling behavior and challenges of microwave power devices as well as highly-scaled depletion- and enhancement-mode devices employing advanced technologies including self-aligned processes, n+ (In,Ga)N ohmic contact regrowth and high aspect ratio T-gates will be discussed. Recent research results on integrating N-polar GaN with Si for prospective novel applications will also be summarized. (invited review)

  3. Bystander cardiopulmonary resuscitation training experience and self-efficacy of age and gender group: a nationwide community survey.

    Science.gov (United States)

    Ro, Young Sun; Shin, Sang Do; Song, Kyoung Jun; Hong, Sung Ok; Kim, Young Taek; Cho, Sung-Il

    2016-08-01

    We hypothesized that recent hands-on practice for cardiopulmonary resuscitation (CPR) would be strongly associated with a higher likelihood of self-efficacy in bystander CPR among laypersons according to age and gender group. We used the National Korean Community Health Survey database of 228921 representatively sampled responders from 253 counties in 2012. Laypersons who had previous CPR training were eligible. Exposure variables were having had CPR training with hands-on practice session with a manikin (Practical-CPR-Training) and CPR training within the last 2 years (Recent-CPR-Training). Primary outcome was self-efficacy in bystander CPR. Multivariable logistic regression analysis was performed. The final model with an interaction term was evaluated to compare the effects of CPR training across different age and gender groups. Of 62425 eligible respondents who have had CPR training, 20213 (32.4%) had Practical-CPR-Training. Adjusted odds ratios (AORs) for self-efficacy were 4.08 (3.78-4.41) in Practical-CPR-Training, 2.61 (2.50-2.73) in male, 1.26 (1.16-1.36) in good self-rated health, 1.19 (1.10-1.29) in high school graduate, 1.19 (1.01-1.39) in persons living with stroke patients in household, and 1.17 (1.10-1.24) in Recent-CPR-Training. In interaction models, Practical-CPR-Training showed higher self-efficacy in all age and gender groups, whereas Recent-CPR-Training was not associated with better self-efficacy in elderly group, male (AOR, 0.90 [0.69-1.18]) and female (AOR, 0.94 [0.72-1.23]). Self-efficacy in bystander CPR was higher in person with recent CPR training with hands-on practice with a manikin. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The copepod Calanus spp. (Calanidae) is repelled by polarized light

    Science.gov (United States)

    Lerner, Amit; Browman, Howard I.

    2016-10-01

    Both attraction and repulsion from linearly polarized light have been observed in zooplankton. A dichotomous choice experiment, consisting of plankton light traps deployed in natural waters at a depth of 30 m that projected either polarized or unpolarized light of the same intensity, was used to test the hypothesis that the North Atlantic copepod, Calanus spp., is linearly polarotactic. In addition, the transparency of these copepods, as they might be seen by polarization insensitive vs. sensitive visual systems, was measured. Calanus spp. exhibited negative polarotaxis with a preference ratio of 1.9:1. Their transparency decreased from 80% to 20% to 30% in the unpolarized, partially polarized, and electric (e-) vector orientation domains respectively - that is, these copepods would appear opaque and conspicuous to a polarization-sensitive viewer looking at them under conditions rich in polarized light. Since the only difference between the two plankton traps was the polarization cue, we conclude that Calanus spp. are polarization sensitive and exhibit negative polarotaxis at low light intensities (albeit well within the sensitivity range reported for copepods). We hypothesize that Calanus spp. can use polarization vision to reduce their risk of predation by polarization-sensitive predators and suggest that this be tested in future experiments.

  5. THE EFFICIENCY AND WAVELENGTH DEPENDENCE OF NEAR-INFRARED INTERSTELLAR POLARIZATION TOWARD THE GALACTIC CENTER

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, Hirofumi; Kurita, Mikio; Kanai, Saori; Sato, Shuji [Department of Astrophysics, Nagoya University, Chikusa-ku, Nagoya 464-8602 (Japan); Nishiyama, Shogo; Nakajima, Yasushi; Tamura, Motohide; Kandori, Ryo [National Astronomical Observatory of Japan, Mitaka, Tokyo 181-8858 (Japan); Nagata, Tetsuya; Yoshikawa, Tatsuhito [Department of Astronomy, Kyoto University, Sakyo-ku, Kyoto 606-8502 (Japan); Kato, Daisuke [Department of Astronomy, School of Science, University of Tokyo, Bunkyo-ku, Tokyo 113-0033 (Japan); Sato, Yaeko; Suenaga, Takuya, E-mail: hattan@z.phys.nagoya-u.ac.jp, E-mail: shogo.nishiyama@nao.ac.jp [Department of Astronomical Sciences, Graduate University for Advanced Studies (Sokendai), Mitaka, Tokyo 181-8858 (Japan)

    2013-04-15

    Near-infrared polarimetric imaging observations toward the Galactic center (GC) have been carried out to examine the efficiency and wavelength dependence of interstellar polarization. A total area of about 5.7 deg{sup 2} is covered in the J, H, and K{sub S} bands. We examined the polarization efficiency, defined as the ratio of the degree of polarization to color excess. The interstellar medium between the GC and us shows a polarization efficiency lower than that in the Galactic disk by a factor of three. Moreover we investigated the spatial variation of the polarization efficiency by comparing it with that of the color excess, degree of polarization, and position angle. The spatial variations of color excess and degree of polarization depend on the Galactic latitude, while the polarization efficiency varies independently of the Galactic structure. Position angles are nearly parallel to the Galactic plane, indicating a longitudinal magnetic field configuration between the GC and us. The polarization efficiency anticorrelates with dispersions of position angles. The low polarization efficiency and its spatial variation can be explained by the differences in the magnetic field directions along the line of sight. From the lower polarization efficiency, we suggest a higher strength of a random component relative to a uniform component of the magnetic field between the GC and us. We also derived the ratios of degree of polarization p{sub H} /p{sub J} = 0.581 {+-} 0.004 and p{sub K{sub S}}/p{sub H} = 0.620 {+-} 0.002. The power-law indices of the wavelength dependence of polarization are {beta}{sub JH} = 2.08 {+-} 0.02 and {beta}{sub HK{sub S}} = 1.76 {+-} 0.01. Therefore, the wavelength dependence of interstellar polarization exhibits flattening toward longer wavelengths in the range of 1.25-2.14 {mu}m. The flattening would be caused by aligned large-size dust grains.

  6. Extensive cardiopulmonary resuscitation for VLBW and ELBW infants: a systematic review and meta-analyses.

    Science.gov (United States)

    Shah, P S

    2009-10-01

    Studies of the outcomes of preterm infants after the receipt of extensive cardiopulmonary resuscitation (CPR) at birth or in the neonatal intensive care units (NICUs) have yielded varied results. A systematic review of the outcomes of very low birth weight (VLBW) and extremely low birth weight (ELBW) infants who received extensive resuscitation at birth or in the NICU was carried out. MEDLINE, EMBASE, CINAHL databases were searched for studies of extensive CPR in the delivery room (DR-CPR) and in NICU (NICU-CPR) that have reported neonatal or long-term outcomes. A total of 20 eligible studies were identified (11 of DR-CPR, 7 of NICU-CPR and 2 had combined data). DR-CPR was associated with an increased risk of mortality (odds ratio (OR) 2.83, 95% confidence interval (CI) 1.92, 4.16) and severe neurological injury (OR 2.27, 95% CI 1.40, 3.67) compared with infants who did not receive extensive CPR. NICU-CPR was associated with an increased risk of mortality (OR 55, 95% CI 15, 195) compared with infants who did not receive CPR; however, confidence limits were wide. The long-term outcome of survivors was reported in a limited number of studies. Extensive CPR at birth or in the NICU for VLBW or ELBW infants was associated with higher risk of mortality.

  7. Measurement of the average polarization of b baryons in hadronic $Z^0$ decays

    CERN Document Server

    Abbiendi, G.; Alexander, G.; Allison, John; Altekamp, N.; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S.F.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Bartoldus, R.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, Kenneth Watson; Bella, G.; Bellerive, A.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bird, S.D.; Blobel, V.; Bloodworth, I.J.; Bobinski, M.; Bock, P.; Bohme, J.; Bonacorsi, D.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brigliadori, L.; Brown, Robert M.; Burckhart, H.J.; Burgard, C.; Burgin, R.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Ciocca, C.; Clarke, P.E.L.; Clay, E.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Couyoumtzelis, C.; Coxe, R.L.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Davis, R.; De Jong, S.; del Pozo, L.A.; De Roeck, A.; Desch, K.; Dienes, B.; Dixit, M.S.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Eatough, D.; Estabrooks, P.G.; Etzion, E.; Evans, H.G.; Fabbri, F.; Fanti, M.; Faust, A.A.; Fiedler, F.; Fierro, M.; Fleck, I.; Folman, R.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gascon, J.; Gascon-Shotkin, S.M.; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Gibson, V.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Harder, K.; Hargrove, C.K.; Hartmann, C.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herndon, M.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hillier, S.J.; Hobson, P.R.; Hocker, James Andrew; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Imrie, D.C.; Ishii, K.; Jacob, F.R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Jones, C.R.; Jovanovic, P.; Junk, T.R.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Koetke, D.S.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kowalewski, Robert V.; Kress, T.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kyberd, P.; Lafferty, G.D.; Lanske, D.; Lauber, J.; Lautenschlager, S.R.; Lawson, I.; Layter, J.G.; Lazic, D.; Lee, A.M.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; List, B.; Littlewood, C.; Lloyd, A.W.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Ludwig, J.; Lui, D.; Macchiolo, A.; Macpherson, A.; Mader, W.; Mannelli, M.; Marcellini, S.; Markopoulos, C.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menke, S.; Merritt, F.S.; Mes, H.; Meyer, J.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mir, R.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nellen, B.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Oreglia, M.J.; Orito, S.; Palinkas, J.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Polok, J.; Przybycien, M.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Roscoe, K.; Rossi, A.M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D.R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W.M.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharf, F.; Scharff-Hansen, P.; Schieck, J.; Schmitt, B.; Schmitt, S.; Schoning, A.; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Sittler, A.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Sproston, M.; Stahl, A.; Stephens, K.; Steuerer, J.; Stoll, K.; Strom, David M.; Strohmer, R.; Surrow, B.; Talbot, S.D.; Tanaka, S.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomson, M.A.; von Torne, E.; Torrence, E.; Towers, S.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turcot, A.S.; Turner-Watson, M.F.; Van Kooten, Rick J.; Vannerem, P.; Verzocchi, M.; Voss, H.; Wackerle, F.; Wagner, A.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; White, J.S.; Wilson, G.W.; Wilson, J.A.; Wyatt, T.R.; Yamashita, S.; Yekutieli, G.; Zacek, V.; Zer-Zion, D.

    1998-01-01

    In the Standard Model, b quarks produced in e^+e^- annihilation at the Z^0 peak have a large average longitudinal polarization of -0.94. Some fraction of this polarization is expected to be transferred to b-flavored baryons during hadronization. The average longitudinal polarization of weakly decaying b baryons, , is measured in approximately 4.3 million hadronic Z^0 decays collected with the OPAL detector between 1990 and 1995 at LEP. Those b baryons that decay semileptonically and produce a \\Lambda baryon are identified through the correlation of the baryon number of the \\Lambda and the electric charge of the lepton. In this semileptonic decay, the ratio of the neutrino energy to the lepton energy is a sensitive polarization observable. The neutrino energy is estimated using missing energy measurements. From a fit to the distribution of this ratio, the value = -0.56^{+0.20}_{-0.13} +/- 0.09 is obtained, where the first error is statistical and the second systematic.

  8. Intermittent Fasting Protects against Alzheimer's Disease Possible through Restoring Aquaporin-4 Polarity.

    Science.gov (United States)

    Zhang, Jingzhu; Zhan, Zhipeng; Li, Xinhui; Xing, Aiping; Jiang, Congmin; Chen, Yanqiu; Shi, Wanying; An, Li

    2017-01-01

    The impairment of amyloid-β (Aβ) clearance in the brain plays a causative role in Alzheimer's disease (AD). Polarity distribution of aquaporin-4 (AQP4) is important to remove Aβ from brain. AQP4 polarity can be influenced by the ratio of two AQP4 isoforms M1 and M23 (AQP4-M1/M23), however, it is unknown whether the ratio of AQP4-M1/M23 changes in AD. Histone deacetylase 3 has been reported to be significantly increased in AD brain. Moreover, evidence indicated that microRNA-130a (miR-130a) possibly mediates the regulation of histone deacetylase 3 on AQP4-M1/M23 ratio by repressing the transcriptional activity of AQP4-M1 in AD. This study aimed to investigate whether intermittent fasting (IF), increasing the level of an endogenous histone deacetylases inhibitor β-hydroxybutyrate, restores AQP4 polarity via miR-130a mediated reduction of AQP4-M1/M23 ratio in protection against AD. The results showed that IF ameliorated cognitive dysfunction, prevented brain from Aβ deposition, and restored the AQP4 polarity in a mouse model of AD (APP/PS1 double-transgenic mice). Additionally, IF down-regulated the expression of AQP4-M1 and histone deacetylase 3, reduced AQP4-M1/M23 ratio, and increased miR-130a expression in the cerebral cortex of APP/PS1 mice. In vitro , β-hydroxybutyrate was found to down-regulate the expression of AQP4-M1 and histone deacetylase 3, reduce AQP4-M1/M23 ratio, and increase AQP4-M23 and miR-130a expression in 2 μM Aβ-treated U251 cells. Interestingly, on the contrary to the result observed in 2 μM Aβ-treated cells, AQP4 expression was obviously decreased in cells exposed to 10 μM Aβ. miR-130a mimic decreased the expression of AQP4-M1 and the ratio of AQP4-M1/M23, as well as silencing histone deacetylase 3 caused the up-regulation of AQP4 and miR-130a, and the reduction of AQP4-M1/M23 ratio in U251 cells. In conclusion, IF exhibits beneficial effects against AD. The mechanism may be associated with recovery of AQP4 polarity, resulting from

  9. Randomized controlled trial of a video decision support tool for cardiopulmonary resuscitation decision making in advanced cancer.

    Science.gov (United States)

    Volandes, Angelo E; Paasche-Orlow, Michael K; Mitchell, Susan L; El-Jawahri, Areej; Davis, Aretha Delight; Barry, Michael J; Hartshorn, Kevan L; Jackson, Vicki Ann; Gillick, Muriel R; Walker-Corkery, Elizabeth S; Chang, Yuchiao; López, Lenny; Kemeny, Margaret; Bulone, Linda; Mann, Eileen; Misra, Sumi; Peachey, Matt; Abbo, Elmer D; Eichler, April F; Epstein, Andrew S; Noy, Ariela; Levin, Tomer T; Temel, Jennifer S

    2013-01-20

    Decision making regarding cardiopulmonary resuscitation (CPR) is challenging. This study examined the effect of a video decision support tool on CPR preferences among patients with advanced cancer. We performed a randomized controlled trial of 150 patients with advanced cancer from four oncology centers. Participants in the control arm (n = 80) listened to a verbal narrative describing CPR and the likelihood of successful resuscitation. Participants in the intervention arm (n = 70) listened to the identical narrative and viewed a 3-minute video depicting a patient on a ventilator and CPR being performed on a simulated patient. The primary outcome was participants' preference for or against CPR measured immediately after exposure to either modality. Secondary outcomes were participants' knowledge of CPR (score range of 0 to 4, with higher score indicating more knowledge) and comfort with video. The mean age of participants was 62 years (standard deviation, 11 years); 49% were women, 44% were African American or Latino, and 47% had lung or colon cancer. After the verbal narrative, in the control arm, 38 participants (48%) wanted CPR, 41 (51%) wanted no CPR, and one (1%) was uncertain. In contrast, in the intervention arm, 14 participants (20%) wanted CPR, 55 (79%) wanted no CPR, and 1 (1%) was uncertain (unadjusted odds ratio, 3.5; 95% CI, 1.7 to 7.2; P advanced cancer who viewed a video of CPR were less likely to opt for CPR than those who listened to a verbal narrative.

  10. Short structured feedback training is equivalent to a mechanical feedback device in two-rescuer BLS: a randomised simulation study.

    Science.gov (United States)

    Pavo, Noemi; Goliasch, Georg; Nierscher, Franz Josef; Stumpf, Dominik; Haugk, Moritz; Breckwoldt, Jan; Ruetzler, Kurt; Greif, Robert; Fischer, Henrik

    2016-05-13

    Resuscitation guidelines encourage the use of cardiopulmonary resuscitation (CPR) feedback devices implying better outcomes after sudden cardiac arrest. Whether effective continuous feedback could also be given verbally by a second rescuer ("human feedback") has not been investigated yet. We, therefore, compared the effect of human feedback to a CPR feedback device. In an open, prospective, randomised, controlled trial, we compared CPR performance of three groups of medical students in a two-rescuer scenario. Group "sCPR" was taught standard BLS without continuous feedback, serving as control. Group "mfCPR" was taught BLS with mechanical audio-visual feedback (HeartStart MRx with Q-CPR-Technology™). Group "hfCPR" was taught standard BLS with human feedback. Afterwards, 326 medical students performed two-rescuer BLS on a manikin for 8 min. CPR quality parameters, such as "effective compression ratio" (ECR: compressions with correct hand position, depth and complete decompression multiplied by flow-time fraction), and other compression, ventilation and time-related parameters were assessed for all groups. ECR was comparable between the hfCPR and the mfCPR group (0.33 vs. 0.35, p = 0.435). The hfCPR group needed less time until starting chest compressions (2 vs. 8 s, p feedback or by using a mechanical audio-visual feedback device was similar. Further studies should investigate whether extended human feedback training could further increase CPR quality at comparable costs for training.

  11. Linear versus circular polarization of head coils - comparison on phantom and in the clinic

    International Nuclear Information System (INIS)

    Schratter, M.; Kramer, J.; Prayer, L.; Wimberger, D.; Imhof, H.; Schmid, W.

    1990-01-01

    Two different head coils - one with linear polarization and the other with circular polarization - were compared under the same measurement conditions. Comparison was done on a phantom with waterfilled and gadolinium-filled pin-holes, as well as on anatomical MR images of 23 volunteers. In three volunteers the whole brain was examined while, in the remaining 20 volunteers the sella region or cerebellopontine angleregion was examined. Criteria for comparison were signal-to-noise ratio, background noise, and detail resolution (phantom), as well as subjective criteria - image sharpness, anatomical, contrast, and recognition of anatomical details -, evaluated on anatomical MR images by four radiologists independently of each other. The results show a significant improvement of signal-to-noise ratio, lower background noise and therefore marked improvement of images harpness, and moderate improvement in the recognition of anatomical details using the circular polarized head coil; as for as detail resolution and anatomical contrast were concerned, however, no significant difference was seen between the two coils. Major advantages of the circular, polarized head coil in clinical application are shorter measurement times (reduced number of acquisitions), as well as thinner slices without loss of signal-to-noise ratio. (orig.) [de

  12. Measurement of the proton form factor ratio at low momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Moshe [Hebrew Univ. of Jerusalem (Israel)

    2016-08-01

    Experiment E08-007-II measured the proton elastic form factor ratio μGE=GM in the momentum transfer range of Q2 ~ 0.02 - 0.08 GeV2, the lowest ever measured by polarization transfer techniques. The experiment was performed at the Thomas Jefferson National Accelerator Facility in Newport News, Virginia, USA during 2012. A polarized electron beam with energies of 1.1, 1.7, and 2.2 GeV was elastically scattered off a polarized solid NH3 target. The asymmetries between the cross section of positive and negative helicity states of the beam were determined. These asymmetries can be used to determine the form factor ratio. In this thesis, we present the asymmetry analysis of the experiment, discuss the main challenges and show preliminary results for part of the data. Preliminary asymmetries indicate an increase in the form factor ratio above unity. However, a complete analysis is required before any conclusion can be made. Further analysis is ongoing, and final asymmetry results and form factor extraction is expected during 2017. We also present first results for 14N asymmetries for elastic and quasi-elastic scattering. The measured asymmetries are in agreement with the shell model approximation, within the low accuracy of the measurement. A change in the asymmetry sign between the elastic and the quasi-elastic processes is seen, and should motivate further theoretical studies. These experimental asymmetries will also be useful for systematic studies of other experiments using polarized NH3 targets.

  13. Dual-band and high-efficiency polarization converter based on metasurfaces at microwave frequencies

    Science.gov (United States)

    Liu, Yajun; Xia, Song; Shi, Hongyu; Zhang, Anxue; Xu, Zhuo

    2016-06-01

    We present a dual-band and high-efficiency polarization converter in microwave regime. The proposed converter can convert a linearly polarized wave to its cross-polarized wave for two distinct bands: Ku (11.5-20.0 GHz) and Ka (28.8-34.0 GHz). It can also convert the linearly polarized wave to a circularly polarized wave at four other frequencies. The experimental results are in good agreement with simulation results for both frequency bands. The polarization conversion ratio is above 0.94 for the Ku-band and 0.90 for the Ka-band. Furthermore, the converter can achieve dual-band and high-efficiency polarization conversion over angles of incidence up to 45°. The converter is also polarization-selective in that only the x- and y-polarized waves can be converted. The physical mechanism of the dual-band polarization conversion effect is interpreted via decomposed electric field components that couple with different plasmon resonance modes of the structure.

  14. Excess B-modes extracted from the Planck polarization maps

    Science.gov (United States)

    Nørgaard-Nielsen, H. U.

    2016-06-01

    One of the main obstacles for extracting the Cosmic Microwave Background (CMB) from mm/submm observations is the pollution from the main Galactic components: synchrotron, free-free and thermal dust emission. The feasibility of using simple neural networks to extract CMB has been demonstrated on both temperature and polarization data obtained by the WMAP satellite. The main goal of this paper is to demonstrate the feasibility of neural networks for extracting the CMB signal from the Planck polarization data with high precision. Both auto-correlation and cross-correlation power spectra within a mask covering about 63 % of the sky have been used together with a ``high pass filter'' in order to minimize the influence of the remaining systematic errors in the Planck Q and U maps. Using the Planck 2015 released polarization maps, a BB power spectrum have been extracted by Multilayer Perceptron neural networks. This spectrum contains a bright feature with signal to noise ratios ≃ 4.5 within 200 ≤ l ≤ 250. The spectrum is significantly brighter than the BICEP2 2015 spectrum, with a spectral behaviour quite different from the ``canonical'' models (weak lensing plus B-modes spectra with different tensor to scalar ratios). The feasibility of the neural network to remove the residual systematics from the available Planck polarization data to a high level has been demonstrated.

  15. Pseudoscalar perturbations and polarization of the cosmic microwave background.

    Science.gov (United States)

    Pospelov, Maxim; Ritz, Adam; Skordis, Constantinos

    2009-07-31

    We show that models of new particle physics containing massless pseudoscalar fields superweakly coupled to photons can be very efficiently probed with CMB polarization anisotropies. The stochastic pseudoscalar fluctuations generated during inflation provide a mechanism for converting E-mode polarization to B-mode during photon propagation from the surface of last scattering. The efficiency of this conversion process is controlled by the dimensionless ratio H/(2pif(a)), where H is the Hubble scale during inflation, and f(a)-1 is the strength of the pseudoscalar coupling to photons. The current observational limits on the B mode constrain this ratio to be less than 0.07, which in many models of inflation translates to a sensitivity to f(a) exceeding 10(14) GeV, which surpasses other tests.

  16. Polarized Raman spectroscopy of chemically vapour deposited diamond films

    International Nuclear Information System (INIS)

    Prawer, S.; Nugent, K.W.; Weiser, P.S.

    1994-01-01

    Polarized micro-Raman spectra of chemically vapour deposited diamond films are presented. It is shown that important parameters often extracted from the Raman spectra such as the ratio of the diamond to non-diamond component of the films and the estimation of the level of residual stress depend on the orientation of the diamond crystallites with respect to the polarization of the incident laser beam. The dependence originates from the fact that the Raman scattering from the non-diamond components in the films is almost completely depolarized whilst the scattering from the diamond components is strongly polarized. The results demonstrate the importance of taking polarization into account when attempting to use Raman spectroscopy in even a semi-quantitative fashion for the assessment of the purity, perfection and stress in CVD diamond films. 8 refs., 1 tab. 2 figs

  17. Excess B‐modes extracted from the Planck polarization maps

    DEFF Research Database (Denmark)

    Nørgaard-Nielsen, Hans Ulrik

    2016-01-01

    on both temperature and polarization data obtained by the WMAP satellite. The main goal of this paper is to demonstrate the feasibility of neural networks for extracting the CMB signal from the Planck polarization data with high precision. Both auto‐correlation and cross‐correlation power spectra within...... a mask covering about 63 % of the sky have been used together with a “high pass filter” in order to minimize the influence of the remaining systematic errors in the Planck Q and U maps. Using the Planck 2015 released polarization maps, a BB power spectrum have been extracted by Multilayer Perceptron...... tensor to scalar ratios). The feasibility of the neural network to remove the residual systematics from the available Planck polarization data to a high level has been demonstrated. (© 2016 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)...

  18. The effect of basic life support education on laypersons' willingness in performing bystander hands only cardiopulmonary resuscitation.

    Science.gov (United States)

    Cho, Gyu Chong; Sohn, You Dong; Kang, Ku Hyun; Lee, Won Woong; Lim, Kyung Soo; Kim, Won; Oh, Bum Jin; Choi, Dai Hai; Yeom, Seok Ran; Lim, Hoon

    2010-06-01

    Recently, hands only CPR (cardiopulmonary resuscitation) has been proposed as an alternative to standard CPR for bystanders. The present study was performed to identify the effect of basic life support (BLS) training on laypersons' willingness in performing standard CPR and hands only CPR. The participants for this study were non-medical personnel who applied for BLS training program that took place in 7 university hospitals in and around Korea for 6 months. Before and after BLS training, all the participants were given questionnaires for bystander CPR, and 890 respondents were included in the final analyses. Self-assessed confidence score for bystander CPR, using a visual analogue scale from 0 to 100, increased from 51.5+/-30.0 before BLS training to 87.0+/-13.7 after the training with statistical significance (p 0.001). Before the training, 19% of respondents reported willingness to perform standard CPR on a stranger, and 30.1% to perform hands only CPR. After the training, this increased to 56.7% of respondents reporting willingness to perform standard CPR, and 71.9%, hands only CPR, on strangers. Before and after BLS training, the odds ratio of willingness to perform hands only CPR versus standard CPR were 1.8 (95% CI 1.5-2.3) and 2.0 (95% CI 1.7-2.6) for a stranger, respectively. Most of the respondents, who reported they would decline to perform standard CPR, stated that fear of liability and fear of disease transmission were deciding factors after the BLS training. The BLS training increases laypersons' confidence and willingness to perform bystander CPR on a stranger. However, laypersons are more willing to perform hands only CPR rather than to perform standard CPR on a stranger regardless of the BLS training. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Cardiopulmonary Resuscitation Training Disparities in the United States.

    Science.gov (United States)

    Blewer, Audrey L; Ibrahim, Said A; Leary, Marion; Dutwin, David; McNally, Bryan; Anderson, Monique L; Morrison, Laurie J; Aufderheide, Tom P; Daya, Mohamud; Idris, Ahamed H; Callaway, Clifton W; Kudenchuk, Peter J; Vilke, Gary M; Abella, Benjamin S

    2017-05-17

    Bystander cardiopulmonary resuscitation (CPR) is associated with increased survival from cardiac arrest, yet bystander CPR rates are low in many communities. The overall prevalence of CPR training in the United States and associated individual-level disparities are unknown. We sought to measure the national prevalence of CPR training and hypothesized that older age and lower socioeconomic status would be independently associated with a lower likelihood of CPR training. We administered a cross-sectional telephone survey to a nationally representative adult sample. We assessed the demographics of individuals trained in CPR within 2 years (currently trained) and those who had been trained in CPR at some point in time (ever trained). The association of CPR training and demographic variables were tested using survey weighted logistic regression. Between September 2015 and November 2015, 9022 individuals completed the survey; 18% reported being currently trained in CPR, and 65% reported training at some point previously. For each year of increased age, the likelihood of being currently CPR trained or ever trained decreased (currently trained: odds ratio, 0.98; 95% CI, 0.97-0.99; P trained: OR, 0.99; 95% CI, 0.98-0.99; P =0.04). Furthermore, there was a greater then 4-fold difference in odds of being currently CPR trained from the 30-39 to 70-79 year old age groups (95% CI, 0.10-0.23). Factors associated with a lower likelihood of CPR training were lesser educational attainment and lower household income ( P training in CPR. Older age, lesser education, and lower income were associated with reduced likelihood of CPR training. These findings illustrate important gaps in US CPR education and suggest the need to develop tailored CPR training efforts to address this variability. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  20. Association between public cardiopulmonary resuscitation education and the willingness to perform bystander cardiopulmonary resuscitation: a metropolitan citywide survey.

    Science.gov (United States)

    Son, Jeong Woo; Ryoo, Hyun Wook; Moon, Sungbae; Kim, Jong-Yeon; Ahn, Jae Yun; Park, Jeong Bae; Seo, Kang Suk; Kim, Jong Kun; Kim, Yun Jeong

    2017-06-01

    Bystander cardiopulmonary resuscitation (CPR) is an important factor associated with improved survival rates and neurologic prognoses in cases of out-of-hospital cardiac arrest. We assessed how factors related to CPR education including timing of education, period from the most recent education session, and content, affected CPR willingness. In February 2012, trained interviewers conducted an interview survey of 1,000 Daegu citizens through an organized questionnaire. The subjects were aged ≥19 years and were selected by quota sampling. Their social and demographic characteristics, as well as CPR and factors related to CPR education, were investigated. Chi-square tests and multivariate logistic regression analyses were used to evaluate how education-related factors affected the willingness to perform CPR. Of total 1,000 cases, 48.0% were male. The multivariate analyses revealed several factors significantly associated with CPR willingness: didactic plus practice group (adjusted odds ratio [AOR], 3.38; 95% confidence interval [CI], 2.3 to 5.0), group with more than four CPR education session (AOR, 7.68; 95% CI, 3.21 to 18.35), interval of less than 6 months from the last CPR education (AOR, 4.47; 95% CI 1.29 to 15.52), and education with automated external defibrillator (AOR, 5.98; 95% CI 2.30 to 15.53). The following were associated with increased willingness to perform CPR: practice sessions and automated electrical defibrillator training in public CPR education, more frequent CPR training, and shorter time period from the most recent CPR education sessions.

  1. Adiabatic/diabatic polarization beam splitter

    Energy Technology Data Exchange (ETDEWEB)

    DeRose, Christopher; Cai, Hong

    2017-09-12

    The various presented herein relate to an on-chip polarization beam splitter (PBS), which is adiabatic for the transverse magnetic (TM) mode and diabatic for the transverse electric (TE) mode. The PBS comprises a through waveguide and a cross waveguide, wherein an electromagnetic beam comprising TE mode and TM mode components is applied to an input port of the through waveguide. The PBS can be utilized to separate the TE mode component from the TM mode component, wherein the TE mode component exits the PBS via an output port of the through waveguide, and the TM mode component exits the PBS via an output port of the cross waveguide. The PBS has a structure that is tolerant to manufacturing variations and exhibits high polarization extinction ratios over a wide bandwidth.

  2. Broadband reflective multi-polarization converter based on single-layer double-L-shaped metasurface

    Science.gov (United States)

    Mao, Chenyang; Yang, Yang; He, Xiaoxiang; Zheng, Jingming; Zhou, Chun

    2017-12-01

    In this paper, a broadband reflective multi-polarization converter based on single-layer double-L-shaped metasurface is proposed. The proposed metasurface can effectively convert linear-polarized (TE/TM) incident wave into the reflected wave with three different polarizations within the frequency bands of 5.5-22.75 GHz. Based on the electric and magnetic resonant features of the double-L-shaped structure, the proposed metasurface can convert linearly polarized waves into cross-polarized waves at three resonant frequency bands. Furthermore, the incident linearly polarized waves can be effectively converted into left/right handed circular-polarized (LHCP and RHCP) waves at other four non-resonance frequency bands. Thus, the proposed metasurface can be regarded as a seven-band multi-polarization converter. The prototype of the proposed polarization converter is analyzed and measured. Both simulated and measured results show the 3-dB axis ratio bandwidth of circular polarization bands and the high polarization conversion efficiency of cross-polarization bands when the incident wave changes from 0° to 30° at both TE and TM modes.

  3. Rescuers' physical fatigue with different chest compression to ventilation methods during simulated infant cardiopulmonary resuscitation.

    Science.gov (United States)

    Boldingh, Anne Marthe; Jensen, Thomas Hagen; Bjørbekk, Ane Torvik; Solevåg, Anne Lee; Nakstad, Britt

    2016-10-01

    To assess development of objective, subjective and indirect measures of fatigue during simulated infant cardiopulmonary resuscitation (CPR) with two different methods. Using a neonatal manikin, 17 subject-pairs were randomized in a crossover design to provide 5-min CPR with a 3:1 chest compression (CC) to ventilation (C:V) ratio and continuous CCs at a rate of 120 min(-1) with asynchronous ventilations (CCaV-120). We measured participants' changes in heart rate (HR) and mean arterial pressure (MAP); perceived level of fatigue on a validated Likert scale; and manikin CC measures. CCaV-120 compared with a 3:1 C:V ratio resulted in a change during 5-min of CPR in HR 49 versus 40 bpm (p = 0.01), and MAP 1.7 versus -2.8 mmHg (p = 0.03); fatigue rated on a Likert scale 12.9 versus 11.4 (p = 0.2); and a significant decay in CC depth after 90 s (p = 0.03). The results indicate a trend toward more fatigue during simulated CPR in CCaV-120 compared to the recommended 3:1 C:V CPR. These results support current guidelines.

  4. High aspect ratio spheromak experiments

    International Nuclear Information System (INIS)

    Robertson, S.; Schmid, P.

    1987-05-01

    The Reversatron RFP (R/a = 50cm/8cm) has been operated as an ohmically heated spheromak of high aspect ratio. We find that the dynamo can drive the toroidal field upward at rates as high as 10 6 G/sec. Discharges can be initiated and ramped upward from seed fields as low as 50 G. Small toroidal bias fields of either polarity (-0.2 < F < 0.2) do not significantly affect operation. 5 refs., 3 figs

  5. Direct Probing of Polarization Charge at Nanoscale Level

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Owoong [Sungkyunkwan Univ., Suwon (Republic of Korea). School of Advanced Materials and Engineering; Seol, Daehee [Sungkyunkwan Univ., Suwon (Republic of Korea). School of Advanced Materials and Engineering; Lee, Dongkyu [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Materials Science and Technology Division; Han, Hee [Korea Research Inst. of Standards and Science (KRISS), Daejeon (South Korea); Lindfors-Vrejoiu, Ionela [Univ. of Cologne (Germany). Physics Inst.; Lee, Woo [Korea Research Inst. of Standards and Science (KRISS), Daejeon (South Korea); Jesse, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Nanophase Materials Sciences; Lee, Ho Nyung [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Materials Science and Technology Division; Kalinin, Sergei V. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Nanophase Materials Sciences; Alexe, Marin [Univ. of Warwick, Coventry (United Kingdom). Dept. of Physics; Kim, Yunseok [Sungkyunkwan Univ., Suwon (Republic of Korea). School of Advanced Materials and Engineering

    2017-11-14

    Ferroelectric materials possess spontaneous polarization that can be used for multiple applications. Owing to a long-term development of reducing the sizes of devices, the preparation of ferroelectric materials and devices is entering the nanometer-scale regime. In order to evaluate the ferroelectricity, there is a need to investigate the polarization charge at the nanoscale. Nonetheless, it is generally accepted that the detection of polarization charges using a conventional conductive atomic force microscopy (CAFM) without a top electrode is not feasible because the nanometer-scale radius of an atomic force microscopy (AFM) tip yields a very low signal-to-noise ratio. But, the detection is unrelated to the radius of an AFM tip and, in fact, a matter of the switched area. In this work, the direct probing of the polarization charge at the nanoscale is demonstrated using the positive-up-negative-down method based on the conventional CAFM approach without additional corrections or circuits to reduce the parasitic capacitance. The polarization charge densities of 73.7 and 119.0 µC cm-2 are successfully probed in ferroelectric nanocapacitors and thin films, respectively. The results we obtained show the feasibility of the evaluation of polarization charge at the nanoscale and provide a new guideline for evaluating the ferroelectricity at the nanoscale.

  6. Construction and test of a polarized proton target

    International Nuclear Information System (INIS)

    Aures, R.

    1983-12-01

    This work describes experiments in which for the first time a proton target has been constructed which is polarized by the ''brute-force'' method. This method requires very low temperatures and high magnetic fields. The low temperatures (down to 10 mK) are obtained by a 3 He/ 4 He dilution refrigerator, the magnetic field (up to 9 T) is produced by a superconducting split pair magnet. The proton target has a volume of about 18 cm 3 and consists of pressed titaniumhydride powder, which has a titanium/-hydrogen ratio of 1:1,96. The hydrogen content is 1,3 mol. Titaniumhydride has the advantage of sufficient heat conductivity at low temperatures and a very high proton density. The heat conductivity of the sample is measured, with and without the presence of a magnetic field. Thermodynamical measurements and adiabatic demagnetisation experiments proved quantitatively the polarization of the protons. The polarization of the proton has been measured in a transmission experiment using polarized neutrons of 1.2 MeV. The result shows a good agreement of theoretical and actual polarization. From the results it can be concluded, that this sample can be used successfully as a polarized proton target for neutron scattering experiments to measure spin-correlations. (orig.) [de

  7. Stable Single Polarization, Single Frequency, and Linear Cavity Er-Doped Fiber Laser Using a Saturable Absorber

    International Nuclear Information System (INIS)

    Li Qi; Yan Feng-Ping; Peng Wan-Jing; Feng Su-Chun; Feng Ting; Tan Si-Yu; Liu Peng

    2013-01-01

    A simple approach for stable single polarization, single frequency, and linear cavity erbium doped fiber laser is proposed and demonstrated. A Fabry—Pérot filter, polarizer and saturable absorber are used together to ensure stable single frequency, single polarization operation. The optical signal-to-noise ratio of the laser is approximately 57 dB, and the Lorentz linewidth is 13.9 kHz. The polarization state of the laser with good stability is confirmed and the degree of polarization is >99%

  8. Remotely Interrogated Passive Polarizing Dosimeter (RIPPeD).

    Energy Technology Data Exchange (ETDEWEB)

    Kemme, Shanalyn A.; Buller, Daniel L.; Dirk, Shawn M.; Boye, Robert R.; Samora, Sally; Washburn, Cody M.; Wheeler, David Roger

    2008-09-01

    Conductive polymers have become an extremely useful class of materials for many optical applications. We have developed an electrochemical growth method for depositing highly conductive ({approx}100 S/cm) polypyrrole. Additionally, we have adapted advanced fabrication methods for use with the polypyrrole resulting in gratings with submicron features. This conductive polymer micro-wire grid provides an optical polarizer with unique properties. When the polymer is exposed to ionizing radiation, its conductivity is affected and the polarization properties of the device, specifically the extinction ratio, change in a corresponding manner. This change in polarization properties can be determined by optically interrogating the device, possibly from a remote location. The result is a passive radiation-sensitive sensor with very low optical visibility. The ability to interrogate the device from a safe standoff distance provides a device useful in potentially dangerous environments. Also, the passive nature of the device make it applicable in applications where external power is not available. We will review the polymer deposition, fabrication methods and device design and modeling. The characterization of the polymer's sensitivity to ionizing radiation and optical testing of infrared polarizers before and after irradiation will also be presented. These experimental results will highlight the usefulness of the conductive infrared polarizer to many security and monitoring applications.

  9. Remotely Interrogated Passive Polarizing Dosimeter (RIPPeD)

    International Nuclear Information System (INIS)

    Kemme, Shanalyn A.; Buller, Daniel L.; Dirk, Shawn M.; Boye, Robert R.; Samora, Sally; Washburn, Cody M.; Wheeler, David Roger

    2008-01-01

    Conductive polymers have become an extremely useful class of materials for many optical applications. We have developed an electrochemical growth method for depositing highly conductive (∼100 S/cm) polypyrrole. Additionally, we have adapted advanced fabrication methods for use with the polypyrrole resulting in gratings with submicron features. This conductive polymer micro-wire grid provides an optical polarizer with unique properties. When the polymer is exposed to ionizing radiation, its conductivity is affected and the polarization properties of the device, specifically the extinction ratio, change in a corresponding manner. This change in polarization properties can be determined by optically interrogating the device, possibly from a remote location. The result is a passive radiation-sensitive sensor with very low optical visibility. The ability to interrogate the device from a safe standoff distance provides a device useful in potentially dangerous environments. Also, the passive nature of the device make it applicable in applications where external power is not available. We will review the polymer deposition, fabrication methods and device design and modeling. The characterization of the polymer's sensitivity to ionizing radiation and optical testing of infrared polarizers before and after irradiation will also be presented. These experimental results will highlight the usefulness of the conductive infrared polarizer to many security and monitoring applications

  10. Determination of Atmospheric Aerosol Characteristics from the Polarization of Scattered Radiation

    Science.gov (United States)

    Harris, F. S., Jr.; McCormick, M. P.

    1973-01-01

    Aerosols affect the polarization of radiation in scattering, hence measured polarization can be used to infer the nature of the particles. Size distribution, particle shape, real and absorption parts of the complex refractive index affect the scattering. From Lorenz-Mie calculations of the 4-Stokes parameters as a function of scattering angle for various wavelengths the following polarization parameters were plotted: total intensity, intensity of polarization in plane of observation, intensity perpendicular to the plane of observation, polarization ratio, polarization (using all 4-Stokes parameters), plane of the polarization ellipse and its ellipticity. A six-component log-Gaussian size distribution model was used to study the effects of the nature of the polarization due to variations in the size distribution and complex refractive index. Though a rigorous inversion from measurements of scattering to detailed specification of aerosol characteristics is not possible, considerable information about the nature of the aerosols can be obtained. Only single scattering from aerosols was used in this paper. Also, the background due to Rayleigh gas scattering, the reduction of effects as a result of multiple scattering and polarization effects of possible ground background (airborne platforms) were not included.

  11. Primordial gravitational waves measurements and anisotropies of CMB polarization rotation

    Directory of Open Access Journals (Sweden)

    Si-Yu Li

    2015-12-01

    Full Text Available Searching for the signal of primordial gravitational waves in the B-modes (BB power spectrum is one of the key scientific aims of the cosmic microwave background (CMB polarization experiments. However, this could be easily contaminated by several foreground issues, such as the interstellar dust grains and the galactic cyclotron electrons. In this paper we study another mechanism, the cosmic birefringence, which can be introduced by a CPT-violating interaction between CMB photons and an external scalar field. Such kind of interaction could give rise to the rotation of the linear polarization state of CMB photons, and consequently induce the CMB BB power spectrum, which could mimic the signal of primordial gravitational waves at large scales. With the recently released polarization data of BICEP2 and the joint analysis data of BICEP2/Keck Array and Planck, we perform a global fitting analysis on constraining the tensor-to-scalar ratio r by considering the polarization rotation angle [α(nˆ] which can be separated into a background isotropic part [α¯] and a small anisotropic part [Δα(nˆ]. Since the data of BICEP2 and Keck Array experiments have already been corrected by using the “self-calibration” method, here we mainly focus on the effects from the anisotropies of CMB polarization rotation angle. We find that including Δα(nˆ in the analysis could slightly weaken the constraints on the tensor-to-scalar ratio r, when using current CMB polarization measurements. We also simulate the mock CMB data with the BICEP3-like sensitivity. Very interestingly, we find that if the effects of the anisotropic polarization rotation angle could not be taken into account properly in the analysis, the constraints on r will be dramatically biased. This implies that we need to break the degeneracy between the anisotropies of the CMB polarization rotation angle and the CMB primordial tensor perturbations, in order to measure the signal of primordial

  12. Motion detection technology as a tool for cardiopulmonary resuscitation (CPR) quality training: a randomised crossover mannequin pilot study.

    Science.gov (United States)

    Semeraro, Federico; Frisoli, Antonio; Loconsole, Claudio; Bannò, Filippo; Tammaro, Gaetano; Imbriaco, Guglielmo; Marchetti, Luca; Cerchiari, Erga L

    2013-04-01

    Outcome after cardiac arrest is dependent on the quality of chest compressions (CC). A great number of devices have been developed to provide guidance during CPR. The present study evaluates a new CPR feedback system (Mini-VREM: Mini-Virtual Reality Enhanced Mannequin) designed to improve CC during training. Mini-VREM system consists of a Kinect(®) (Microsoft, Redmond, WA, USA) motion sensing device and specifically developed software to provide audio-visual feedback. Mini-VREM was connected to a commercially available mannequin (Laerdal Medical, Stavanger, Norway). Eighty trainees (healthcare professionals and lay people) volunteered in this randomised crossover pilot study. All subjects performed a 2 min CC trial, 1h pause and a second 2 min CC trial. The first group (FB/NFB, n=40) performed CC with Mini-VREM feedback (FB) followed by CC without feedback (NFB). The second group (NFB/FB, n=40) performed vice versa. Primary endpoints: adequate compression (compression rate between 100 and 120 min(-1) and compression depth between 50 and 60mm); compressions rate within 100-120 min(-1); compressions depth within 50-60mm. When compared to the performance without feedback, with Mini-VREM feedback compressions were more adequate (FB 35.78% vs. NFB 7.27%, p<0.001) and more compressions achieved target rate (FB 72.04% vs. 31.42%, p<0.001) and target depth (FB 47.34% vs. 24.87%, p=0.002). The participants perceived the system to be easy to use with effective feedback. The Mini-VREM system was able to improve significantly the CC performance by healthcare professionals and by lay people in a simulated CA scenario, in terms of compression rate and depth. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. High ambient contrast ratio OLED and QLED without a circular polarizer

    International Nuclear Information System (INIS)

    Tan, Guanjun; Zhu, Ruidong; Luo, Zhenyue; Wu, Shin-Tson; Tsai, Yi-Shou; Lee, Kuo-Chang; Lee, Yuh-Zheng

    2016-01-01

    A high ambient contrast ratio display device using a transparent organic light emitting diode (OLED) or transparent quantum-dot light-emitting diode (QLED) with embedded multilayered structure and absorber is proposed and its performance is simulated. With the help of multilayered structure, the device structure allows almost all ambient light to get through the display device and be absorbed by the absorber. Because the reflected ambient light is greatly reduced, the ambient contrast ratio of the display system is improved significantly. Meanwhile, the multilayered structure helps to lower the effective refractive index, which in turn improves the out-coupling efficiency of the display system. Potential applications for sunlight readable flexible and rollable displays are emphasized. (paper)

  14. Estimation of Melt Pond Fractions on First Year Sea Ice Using Compact Polarization SAR

    Science.gov (United States)

    Li, Haiyan; Perrie, William; Li, Qun; Hou, Yijun

    2017-10-01

    Melt ponds are a common feature on Arctic sea ice. They are linked to the sea ice surface albedo and transmittance of energy to the ocean from the atmosphere and thus constitute an important process to parameterize in Arctic climate models and simulations. This paper presents a first attempt to retrieve the melt pond fraction from hybrid-polarized compact polarization (CP) SAR imagery, which has wider swath and shorter revisit time than the quad-polarization systems, e.g., from RADARSAT-2 (RS-2). The co-polarization (co-pol) ratio has been verified to provide estimates of melt pond fractions. However, it is a challenge to link CP parameters and the co-pol ratio. The theoretical possibility is presented, for making this linkage with the CP parameter C22/C11 (the ratio between the elements of the coherence matrix of CP SAR) for melt pond detection and monitoring with the tilted-Bragg scattering model for the ocean surface. The empirical transformed formulation, denoted as the "compact polarization and quad-pol" ("CPQP") model, is proposed, based on 2062 RS-2 quad-pol SAR images, collocated with in situ measurements. We compared the retrieved melt pond fraction with CP parameters simulated from quad-pol SAR data with results retrieved from the co-pol ratio from quad-pol SAR observations acquired during the Arctic-Ice (Arctic-Ice Covered Ecosystem in a Rapidly Changing Environment) field project. The results are shown to be comparable for observed melt pond measurements in spatial and temporal distributions. Thus, the utility of CP mode SAR for melt pond fraction estimation on first year level ice is presented.

  15. Polar representation of centrifugal pump homologous curves

    International Nuclear Information System (INIS)

    Veloso, Marcelo Antonio; Mattos, Joao Roberto Loureiro de

    2008-01-01

    Essential for any mathematical model designed to simulate flow transient events caused by pump operations is the pump performance data. The performance of a centrifugal pump is characterized by four basic parameters: the rotational speed, the volumetric flow rate, the dynamic head, and the hydraulic torque. Any one of these quantities can be expressed as a function of any two others. The curves showing the relationships between these four variables are called the pump characteristic curves, also referred to as four-quadrant curves. The characteristic curves are empirically developed by the pump manufacturer and uniquely describe head and torque as functions of volumetric flow rate and rotation speed. Because of comprising a large amount of points, the four-quadrant configuration is not suitable for computational purposes. However, it can be converted to a simpler form by the development of the homologous curves, in which dynamic head and hydraulic torque ratios are expressed as functions of volumetric flow and rotation speed ratios. The numerical use of the complete set of homologous curves requires specification of sixteen partial curves, being eight for the dynamic head and eight for the hydraulic torque. As a consequence, the handling of homologous curves is still somewhat complicated. In solving flow transient problems that require the pump characteristic data for all the operation zones, the polar form appears as the simplest way to represent the homologous curves. In the polar method, the complete characteristics of a pump can be described by only two closed curves, one for the dynamic head and other for the hydraulic torque, both in function of a single angular coordinate defined adequately in terms of the quotient between volumetric flow ratio and rotation speed ratio. The usefulness and advantages of this alternative method are demonstrated through a practical example in which the homologous curves for a pump of the type used in the main coolant loops of a

  16. Active polarization imaging system based on optical heterodyne balanced receiver

    Science.gov (United States)

    Xu, Qian; Sun, Jianfeng; Lu, Zhiyong; Zhou, Yu; Luan, Zhu; Hou, Peipei; Liu, liren

    2017-08-01

    Active polarization imaging technology has recently become the hot research field all over the world, which has great potential application value in the military and civil area. By introducing active light source, the Mueller matrix of the target can be calculated according to the incident light and the emitted or reflected light. Compared with conventional direct detection technology, optical heterodyne detection technology have higher receiving sensitivities, which can obtain the whole amplitude, frequency and phase information of the signal light. In this paper, an active polarization imaging system will be designed. Based on optical heterodyne balanced receiver, the system can acquire the horizontal and vertical polarization of reflected optical field simultaneously, which contain the polarization characteristic of the target. Besides, signal to noise ratio and imaging distance can be greatly improved.

  17. Boundary between the thermal and statistical polarization regimes in a nuclear spin ensemble

    International Nuclear Information System (INIS)

    Herzog, B. E.; Cadeddu, D.; Xue, F.; Peddibhotla, P.; Poggio, M.

    2014-01-01

    As the number of spins in an ensemble is reduced, the statistical fluctuations in its polarization eventually exceed the mean thermal polarization. This transition has now been surpassed in a number of recent nuclear magnetic resonance experiments, which achieve nanometer-scale detection volumes. Here, we measure nanometer-scale ensembles of nuclear spins in a KPF 6 sample using magnetic resonance force microscopy. In particular, we investigate the transition between regimes dominated by thermal and statistical nuclear polarization. The ratio between the two types of polarization provides a measure of the number of spins in the detected ensemble.

  18. Spectrally efficient polarization multiplexed direct-detection OFDM system without frequency gap.

    Science.gov (United States)

    Wei, Chia-Chien; Zeng, Wei-Siang; Lin, Chun-Ting

    2016-01-25

    We experimentally demonstrate a spectrally efficient direct-detection orthogonal frequency-division multiplexing (DD-OFDM) system. In addition to polarization-division multiplexing, removing the frequency gap further improves the spectral efficiency of the OFDM system. The frequency gap between a reference carrier and OFDM subcarriers avoids subcarrier-to-subcarrier beating interference (SSBI) in traditional DD-OFDM systems. Without dynamic polarization control, the resulting interference after square-law direct detection in the proposed gap-less system is polarization-dependent and composed of linear inter-carrier interference (ICI) and nonlinear SSBI. Thus, this work proposes an iterative multiple-input multiple-output detection scheme to remove the mixed polarization-dependent interference. Compared to the previous scheme, which only removes ICI, the proposed scheme can further eliminate SSBI to achieve the improvement of ∼ 7 dB in signal-to-noise ratio. Without the need for polarization control, we successfully utilize 7-GHz bandwidth to transmit a 39.5-Gbps polarization multiplexed OFDM signal over 100 km.

  19. Waveguide resonances with selectable polarization in an infrared thermal emitter

    Directory of Open Access Journals (Sweden)

    Wei-Lun Huang

    2017-08-01

    Full Text Available A multi-band infrared thermal emitter with polarized waveguide resonances was investigated. The device is constructed by embedding the metallic grating strips within the resonant cavity of a metal/dielectric/metal (MDM structure. The proposed arrangement makes it possible to generate waveguide resonances with mutually orthogonal polarization, thereby providing an additional degree of freedom to vary the resonant wavelengths and polarizations in the medium infrared region. The measured reflection spectra and the finite-difference time-domain (FDTD simulation indicated that the electric fields of the waveguide modes with two orthogonal polarizations are distributed in different regions of the cavity. Resonant wavelengths in different polarizations can be adjusted by altering the period, the metallic line width, or the position of the embedded gold strips. The ratio of the full width at half maximum (FWHM to the peak wavelength was achieved to be smaller than 0.035. This study demonstrated a multi-band infrared thermal emission featuring a narrow bandwidth and polarization characteristics, which is quite suitable to be applied to the non-dispersive infrared (NDIR detection system.

  20. Reduction of cross-polarized reflection to enhance dual-band absorption

    Science.gov (United States)

    Kundu, Debidas; Mohan, Akhilesh; Chakrabarty, Ajay

    2016-11-01

    In this paper, cross-polarized reflection from a periodic array of metal-dielectric-metal resonator units is reduced to improve its absorbing performance. Through this simple and typical example, it is shown that some reported absorbers are actually poor absorbers but efficient polarization converters, when the cross-polarized reflection is considered. Using a frequency selective surface, sandwiched between the top layer and the ground plane, the cross-polarized reflection is reduced by 7.2 dB at 5.672 GHz and 8.5 dB at 9.56 GHz, while negligibly affecting the co-polarized reflection reduction performance. The polarization conversion ratio is reduced from 90. 74% to 34.12% and 98.51% to 27.2% and total absorption is improved up to 80% from 26% and 21% around the two resonant frequencies. The reflection characteristics of the proposed absorber are quantitatively analyzed using interference theory, where the near field coupling of the resonant geometries and ground is taken into account. Measurement results show good agreement with both the numerically simulated and theoretical results.

  1. Step-flow growth mode instability of N-polar GaN under N-excess

    International Nuclear Information System (INIS)

    Chèze, C.; Sawicka, M.; Siekacz, M.; Łucznik, B.; Boćkowski, M.; Skierbiszewski, C.; Turski, H.; Cywiński, G.; Smalc-Koziorowska, J.; Weyher, J. L.; Kryśko, M.

    2013-01-01

    GaN layers were grown on N-polar GaN substrates by plasma-assisted molecular beam epitaxy under different III/V ratios. Ga-rich conditions assure step-flow growth with atomically flat surface covered by doubly-bunched steps, as for Ga-polar GaN. Growth under N-excess however leads to an unstable step-flow morphology. Particularly, for substrates slightly miscut towards , interlacing fingers are covered by atomic steps pinned on both sides by small hexagonal pits. In contrast, a three-dimensional island morphology is observed on the Ga-polar equivalent sample. We attribute this result to lower diffusion barriers on N-polar compared to Ga-polar GaN under N-rich conditions

  2. Polarization of lanthanum nucleus by dynamic polarization method

    International Nuclear Information System (INIS)

    Adachi, Toshikazu; Ishimoto, Shigeru; Masuda, Yasuhiro; Morimoto, Kimio

    1989-01-01

    Preliminary studies have been carried out concerning the application of a dynamic polarization method to polarizing lanthanum fluoride single crystal to be employed as target in experiments with time reversal invariance. The present report briefly outlines the dynamic polarization method and describes some preliminary studies carried out so far. Dynamic polarization is of particular importance because no techniques are currently available that can produce highly polarized static nucleus. Spin interaction between electrons and protons (nuclei) plays a major role in the dynamic polarization method. In a thermal equilibrium state, electrons are polarized almost completely while most protons are not polarized. Positively polarized proton spin is produced by applying microwave to this system. The most hopeful candidate target material is single crystal of LaF 3 containing neodymium because the crystal is chemically stable and easy to handle. The spin direction is of great importance in experiments with time reversal invariance. The spin of neutrons in the target can be cancelled by adjusting the external magnetic field applied to a frozen polarized target. In a frozen spin state, the polarity decreases slowly with a relaxation time that depends on the external magnetic field and temperature. (N.K.)

  3. Polarized neutrons

    International Nuclear Information System (INIS)

    Williams, W.G.

    1988-01-01

    The book on 'polarized neutrons' is intended to inform researchers in condensed matter physics and chemistry of the diversity of scientific problems that can be investigated using polarized neutron beams. The contents include chapters on:- neutron polarizers and instrumentation, polarized neutron scattering, neutron polarization analysis experiments and precessing neutron polarization. (U.K.)

  4. Design of ultrathin dual-resonant reflective polarization converter with customized bandwidths

    Science.gov (United States)

    Kundu, Debidas; Mohan, Akhilesh; Chakrabarty, Ajay

    2017-10-01

    In this paper, an ultrathin dual-resonant reflective polarization converter is proposed to obtain customized bandwidths using precise space-filling technique to its top geometry. The unit cell of the dual-resonant prototype consists of conductive square ring with two diagonally arranged slits, supported by metal-backed thin dielectric layer. It offers two narrow bands with fractional bandwidths of 3.98 and 6.65% and polarization conversion ratio (PCR) of 97.16 and 98.87% at 4.52 and 6.97 GHz, respectively. The resonances are brought in proximity to each other by changing the length of surface current paths of the two resonances. By virtue of this mechanism, two polarization converters with two different types of bandwidths are obtained. One polarization converter produces a full-width at half-maxima PCR bandwidth of 34%, whereas another polarization converter produces a 90% PCR bandwidth of 19%. All the proposed polarization converters are insensitive to wide variations of incident angle for both TE- and TM-polarized incident waves. Measured results show good agreement with the numerically simulated results.

  5. Cathodoluminescence study of Mg activation in non-polar and semi-polar faces of undoped/Mg-doped GaN core-shell nanorods

    Science.gov (United States)

    Hortelano, V.; Martínez, O.; Cuscó, R.; Artús, L.; Jiménez, J.

    2016-03-01

    Spectrally and spatially resolved cathodoluminescence (CL) measurements were carried out at 80 K on undoped/Mg-doped GaN core-shell nanorods grown by selective area growth metalorganic vapor phase epitaxy in order to investigate locally the optical activity of the Mg dopants. A study of the luminescence emission distribution over the different regions of the nanorods is presented. We have investigated the CL fingerprints of the Mg incorporation into the non-polar lateral prismatic facets and the semi-polar facets of the pyramidal tips. The amount of Mg incorporation/activation was varied by using several Mg/Ga flow ratios and post-growth annealing treatment. For lower Mg/Ga flow ratios, the annealed nanorods clearly display a donor-acceptor pair band emission peaking at 3.26-3.27 eV and up to 4 LO phonon replicas, which can be considered as a reliable indicator of effective p-type Mg doping in the nanorod shell. For higher Mg/Ga flow ratios, a substantial enhancement of the yellow luminescence emission as well as several emission subbands are observed, which suggests an increase of disorder and the presence of defects as a consequence of the excess Mg doping.

  6. Design of broadband single polarized antenna

    Science.gov (United States)

    Shin, Phoo Kho; Aziz, Mohamad Zoinol Abidin Abd.; Ahmad, Badrul Hisham; Ramli, Mohamad Hafize Bin; Fauzi, Noor Azamiah Md; Malek, Mohd Fareq Abd

    2015-05-01

    In practical wireless communication application, bandwidth enhancement becomes one of the major design considerations. At the same time, circular polarized (CP) antenna received much attention for the applications of modern wireless communication system when compared to linear polarized (LP) antenna. This is because CP antenna can reduce the multipath effect. Hence, broadband antenna with operating frequency at 2.4GHz for WLAN application is proposed. The proposed antenna is done by using L-probe amendment with rectangular patch. The rectangular patch and copper ground plane is separated with 10mm air gap. This approach is used to enhance the bandwidth and the gain of the proposed antenna. The bandwidth of the designed antenna is more than 200MHz which meet broadband application. The return loss for the antenna is below -10dB to achieved 90% matching efficiency. The position of L-probe feed is altered in order to obtained different polarizations. The broadband antenna had been designed and simulated by using Computer Simulation Technology (CST) software. In this paper, the comparison for single polarized antenna with the design of non-inverted patch and inverted patch is discussed. The characteristics of the S-parameter, axial ratio, gain, surface current for each designed antenna are analyzed.

  7. Intermittent Fasting Protects against Alzheimer’s Disease Possible through Restoring Aquaporin-4 Polarity

    Directory of Open Access Journals (Sweden)

    Jingzhu Zhang

    2017-11-01

    Full Text Available The impairment of amyloid-β (Aβ clearance in the brain plays a causative role in Alzheimer’s disease (AD. Polarity distribution of aquaporin-4 (AQP4 is important to remove Aβ from brain. AQP4 polarity can be influenced by the ratio of two AQP4 isoforms M1 and M23 (AQP4-M1/M23, however, it is unknown whether the ratio of AQP4-M1/M23 changes in AD. Histone deacetylase 3 has been reported to be significantly increased in AD brain. Moreover, evidence indicated that microRNA-130a (miR-130a possibly mediates the regulation of histone deacetylase 3 on AQP4-M1/M23 ratio by repressing the transcriptional activity of AQP4-M1 in AD. This study aimed to investigate whether intermittent fasting (IF, increasing the level of an endogenous histone deacetylases inhibitor β-hydroxybutyrate, restores AQP4 polarity via miR-130a mediated reduction of AQP4-M1/M23 ratio in protection against AD. The results showed that IF ameliorated cognitive dysfunction, prevented brain from Aβ deposition, and restored the AQP4 polarity in a mouse model of AD (APP/PS1 double-transgenic mice. Additionally, IF down-regulated the expression of AQP4-M1 and histone deacetylase 3, reduced AQP4-M1/M23 ratio, and increased miR-130a expression in the cerebral cortex of APP/PS1 mice. In vitro, β-hydroxybutyrate was found to down-regulate the expression of AQP4-M1 and histone deacetylase 3, reduce AQP4-M1/M23 ratio, and increase AQP4-M23 and miR-130a expression in 2 μM Aβ-treated U251 cells. Interestingly, on the contrary to the result observed in 2 μM Aβ-treated cells, AQP4 expression was obviously decreased in cells exposed to 10 μM Aβ. miR-130a mimic decreased the expression of AQP4-M1 and the ratio of AQP4-M1/M23, as well as silencing histone deacetylase 3 caused the up-regulation of AQP4 and miR-130a, and the reduction of AQP4-M1/M23 ratio in U251 cells. In conclusion, IF exhibits beneficial effects against AD. The mechanism may be associated with recovery of AQP4 polarity

  8. Study of mechanical compression of spin-polarized 3He gas

    International Nuclear Information System (INIS)

    Becker, J.; Heil, W.; Krug, B.; Leduc, M.; Meyerhoff, M.; Nacher, P.J.; Otten, E.W.; Prokscha, T.; Schearer, L.D.; Surkau, R.

    1994-01-01

    We have piloted mechanical compression of spinpolarized 3He by a titanium piston compressor. Questions of materials and design are discussed, followed by a thorough investigation of relaxation sources in the course of compression. The latter are traced mainly to regions with large surface to volume ratio, through which fast passage is demanded, therefore. We conclude from this feasibility study that polarized 3He may be compressed this way up to many bars without serious polarization losses. ((orig.))

  9. The Correlation Characteristics of Polarization Backscattering Matrix of Dense Chaff Clouds

    Directory of Open Access Journals (Sweden)

    B. Tang

    2018-04-01

    Full Text Available This paper studied the correlation characteristics of the polarization backscattering matrix of the dense chaff cloud with uniform orientation and location distributions in circular symmetry region. Based on the theoretical analysis and numerical experiments, the correlation coefficients of the four elements in the polarization backscattering matrix are obtained, and the results indicate that the cross to co-polar correlation coefficient is still zero; and that the sum of the co-polar cross-correlation coefficient and the two times of linear depolarization ratio equals one. The results are beneficial for better understanding of the backscattering characteristics of dense chaff clouds, and are useful in the application of jamming recognition in radar electronic warfare. Numerical experiments are performed by using the method of moments.

  10. The influence of the droplet clouds microstructure on the polarization characteristics of a double scattering lidar signal

    Directory of Open Access Journals (Sweden)

    Nee Yevgeniy

    2016-01-01

    Full Text Available The results of calculation of the ratio of polarization degrees of the double scattering lidar return from droplet clouds with different microstructure at sensing by circularly and linearly polarized radiation are given in this report. The influence of the droplet size on ellipse parameters of linearly polarized radiation are discussed.

  11. The impact of compliant surfaces on in-hospital chest compressions: effects of common mattresses and a backboard.

    NARCIS (Netherlands)

    Noordergraaf, G.J.; Paulussen, I.W.; Venema, A.; Berkom, P.F. van; Woerlee, P.H.; Scheffer, G.J.; Noordergraaf, A.

    2009-01-01

    PURPOSE: To evaluate, in a hospital setting, the influence of different, common mattresses, with and without a backboard, on chest movement during CPR. DESIGN AND SETTING: Sixty CPR sessions (140s each, 30:2, C:R ratio 1:1) were performed using a manikin on standard hospital mattresses, with or

  12. Controlling the branching ratio of photodissociation using aligned molecules

    DEFF Research Database (Denmark)

    Larsen, J.J.; Wendt-Larsen, I.; Stapelfeldt, H.

    1999-01-01

    Using a sample of iodine molecules, aligned by a strong, linearly polarized laser pulse, we control the branching ratio of the I+I and I+I* photodissociation channels by a factor of 26. The control relies on selective photoexcitation of two potential curves that each correlate adiabatically...

  13. Modeling of finite aspect ratio effects on current drive

    International Nuclear Information System (INIS)

    Wright, J.C.; Phillips, C.K.

    1996-01-01

    Most 2D RF modeling codes use a parameterization of current drive efficiencies to calculate fast wave driven currents. This parameterization assumes a uniform diffusion coefficient and requires a priori knowledge of the wave polarizations. These difficulties may be avoided by a direct calculation of the quasilinear diffusion coefficient from the Kennel-Englemann form with the field polarizations calculated by a full wave code. This eliminates the need to use the approximation inherent in the parameterization. Current profiles are then calculated using the adjoint formulation. This approach has been implemented in the FISIC code. The accuracy of the parameterization of the current drive efficiency, η, is judged by a comparison with a direct calculation: where χ is the adjoint function, ε is the kinetic energy, and rvec Γ is the quasilinear flux. It is shown that for large aspect ratio devices (ε → 0), the parameterization is nearly identical to the direct calculation. As the aspect ratio approaches unity, visible differences between the two calculations appear

  14. Slotted Circularly Polarized Microstrip Antenna for RFID Application

    Directory of Open Access Journals (Sweden)

    S. Kumar

    2017-12-01

    Full Text Available A single layer coaxial fed rectangular microstrip slotted antenna for circular polarization (CP is proposed for radio frequency identification (RFID application. Two triangular shaped slots and one rectangular slot along the diagonal axis of a square patch have been embedded. Due to slotted structure along the diagonal axis and less surface area, good quality of circular polarization has been obtained with the reduction in the size of microstrip antenna by 4.04 %. Circular polarization radiation performance has been studied by size and angle variation of diagonally slotted structures. The experimental result found for 10-dB return loss is 44 MHz with 10MHz of 3dB Axial Ratio (AR bandwidth respectively at the resonant frequency 910 MHz. The overall proposed antenna size including the ground plane is 80 mm x 80 mm x 4.572 mm.

  15. Basic and advanced paediatric cardiopulmonary resuscitation - guidelines of the Australian and New Zealand Resuscitation Councils 2010.

    Science.gov (United States)

    Tibballs, James; Aickin, Richard; Nuthall, Gabrielle

    2012-07-01

    Guidelines for basic and advanced paediatric cardiopulmonary resuscitation (CPR) have been revised by Australian and New Zealand Resuscitation Councils. Changes encourage CPR out-of-hospital and aim to improve the quality of CPR in-hospital. Features of basic CPR include: omission of abdominal thrusts for foreign body airway obstruction; commencement with chest compression followed by ventilation in a ratio of 30:2 or compression-only CPR if the rescuer is unwilling/unable to give expired-air breathing when the victim is 'unresponsive and not breathing normally'. Use of automated external defibrillators is encouraged. Features of advanced CPR include: prevention of cardiac arrest by rapid response systems; restriction of pulse palpation to 10 s to diagnosis cardiac arrest; affirmation of 15:2 compression-ventilation ratio for children and for infants other than newly born; initial bag-mask ventilation before tracheal intubation; a single direct current shock of 4 J/kg for ventricular fibrillation (VF) and pulseless ventricular tachycardia followed by immediate resumption of CPR for 2 min without analysis of cardiac rhythm and avoidance of unnecessary interruption of continuous external cardiac compressions. Monitoring of exhaled carbon dioxide is recommended to detect non-tracheal intubation, assess quality of CPR, and to help match ventilation to reduced cardiac output. The intraosseous route is recommended if immediate intravenous access is impossible. Amiodarone is strongly favoured over lignocaine for refractory VF and adrenaline over atropine for severe bradycardia, asystole and pulseless electrical activity. Family presence at resuscitation is encouraged. Therapeutic hypothermia is acceptable after resuscitation to improve neurological outcome. Extracorporeal circulatory support for in-hospital cardiac arrest may be used in equipped centres. © 2011 The Authors. Journal of Paediatrics and Child Health © 2011 Paediatrics and Child Health Division (Royal

  16. IPHAS J062746.41+014811.3: A DEEPLY ECLIPSING INTERMEDIATE POLAR

    International Nuclear Information System (INIS)

    Aungwerojwit, A.; Gänsicke, B. T.; Wheatley, P. J.; Pyrzas, S.; Staels, B.; Krajci, T.; Rodríguez-Gil, P.

    2012-01-01

    We present time-resolved photometry of a cataclysmic variable discovered in the Isaac Newton Telescope Photometric Hα Survey of the northern galactic plane, IPHAS J062746.41+014811.3, and classify the system as the fourth deeply eclipsing intermediate polar known with an orbital period of P orb = 8.16 hr and a spin period of P spin = 2210 s. The system shows mild variations of its brightness that appear to be accompanied by a change in the amplitude of the spin modulation at optical wavelengths and a change in the morphology of the eclipse profile. The inferred magnetic moment of the white dwarf is μ wd ∼ (6-7) × 10 33 G cm 3 , and in this case IPHAS J062746.41+014811.3 will evolve either into a short-period EX Hya-like intermediate polar with a large P spin /P orb ratio or, perhaps more likely, into a synchronized polar. Swift observations show that the system is an ultraviolet and X-ray source, with a hard X-ray spectrum that is consistent with those seen in other intermediate polars. The ultraviolet light curve shows orbital modulation and an eclipse, while the low signal-to-noise ratio X-ray light curve does not show a significant modulation on the spin period. The measured X-ray flux is about an order of magnitude lower than would be expected from scaling by the optical fluxes of well-known X-ray-selected intermediate polars.

  17. Measuring top-quark polarization in top-pair + missing-energy events.

    Science.gov (United States)

    Berger, Edmond L; Cao, Qing-Hong; Yu, Jiang-Hao; Zhang, Hao

    2012-10-12

    The polarization of a top quark can be sensitive to new physics beyond the standard model. Since the charged lepton from top-quark decay is maximally correlated with the top-quark spin, it is common to measure the polarization from the distribution in the angle between the charged lepton and the top-quark directions. We propose a novel method based on the charged lepton energy fraction and illustrate the method with a detailed simulation of top-quark pairs produced in supersymmetric top squark pair production. We show that the lepton energy ratio distribution that we define is very sensitive to the top-quark polarization but insensitive to the precise measurement of the top-quark energy.

  18. Polarization Beam Splitter Based on a Self-Collimation Michelson Interferometer in a Silicon Photonic Crystal

    International Nuclear Information System (INIS)

    Chen Xi-Yao; Lin Gui-Min; Li Jun-Jun; Xu Xiao-Fu; Jiang Jun-Zhen; Qiang Ze-Xuan; Qiu Yi-Shen; Li Hui

    2012-01-01

    A polarization beam splitter based on a self-collimation Michelson interferometer (SMI) in a hole-type silicon photonic crystal is proposed and numerically demonstrated. Utilizing the polarization dependence of the transmission spectra of the SMI and polarization peak matching method, the SMI can work as a polarization beam splitter (PBS) by selecting an appropriate path length difference in the structure. Based on its novel polarization beam splitting mechanics, the polarization extinction ratios (PERs) for TM and TE modes are as high as 18.4 dB and 24.3 dB, respectively. Since its dimensions are only several operating wavelengths, the PBS may have practical applications in photonic integrated circuits. (fundamental areas of phenomenology(including applications))

  19. Workshop on polarized neutron filters and polarized pulsed neutron experiments

    International Nuclear Information System (INIS)

    Itoh, Shinichi

    2004-07-01

    The workshop was held in KEK by thirty-three participants on April 26, 2004. The polarized neutron filter method was only discussed. It consists of three parts; the first part was discussed on the polarized neutron methods, the second part on the polarized neutron experiments and the third on the pulse neutron spectrometer and polarized neutron experiments. The six papers were presented such as the polarized 3 He neutron spin filter, neutron polarization by proton polarized filter, soft master and neutron scattering, polarized neutron in solid physics, polarization experiments by chopper spectroscope and neutron polarization system in superHRPD. (S.Y.)

  20. The key changes in pediatric and neonatal cardiopulmonary resuscitation.

    Science.gov (United States)

    Sung, Dyi-Shiang; Hsieh, Kai-Sheng

    2007-01-01

    The American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC) were changed in 2005. There were some key changes in the recommendations for pediatric basic and advanced life support, and neonatal resuscitation. The key changes included: emphasis on effective compressions (push hard, push fast, allow full chest recoil and minimize interruptions in compressions), a single compression-ventilation ratio (30:2) CPR for all groups of ages (except neonate), confirmation of effective ventilations, medication given and defibrillator charged without interruption of CPR, not recommended to routine tracheal suction the vigorous meconium-stained baby in newborn resuscitation, etc. We illustrate the major key changes and hope everyone is well trained to perform high quality CPR.

  1. Dielectric and Piezoelectric Properties of PZT Composite Thick Films with Variable Solution to Powder Ratios.

    Science.gov (United States)

    Wu, Dawei; Zhou, Qifa; Shung, Koping Kirk; Bharadwaja, Srowthi N; Zhang, Dongshe; Zheng, Haixing

    2009-05-08

    The use of PZT films in sliver-mode high-frequency ultrasonic transducers applications requires thick, dense, and crack-free films with excellent piezoelectric and dielectric properties. In this work, PZT composite solutions were used to deposit PZT films >10 μm in thickness. It was found that the functional properties depend strongly on the mass ratio of PZT sol-gel solution to PZT powder in the composite solution. Both the remanent polarization, P(r), and transverse piezoelectric coefficient, e(31,) (f), increase with increasing proportion of the sol-gel solution in the precursor. Films prepared using a solution-to-powder mass ratio of 0.5 have a remanent polarization of 8 μC/cm(2), a dielectric constant of 450 (at 1 kHz), and e(31,) (f) = -2.8 C/m(2). Increasing the solution-to-powder mass ratio to 6, the films were found to have remanent polarizations as large as 37 μC/cm(2), a dielectric constant of 1250 (at 1 kHz) and e(31,) (f) = -5.8 C/m(2).

  2. Estimating cost-effectiveness of mass cardiopulmonary resuscitation training strategies to improve survival from cardiac arrest in private locations.

    Science.gov (United States)

    Swor, Robert; Compton, Scott

    2004-01-01

    Most cardiopulmonary resuscitation (CPR) trainees are young, and most cardiac arrests occur in private residences witnessed by older individuals. To estimate the cost-effectiveness of a CPR training program targeted at citizens over the age of 50 years compared with that of current nontargeted public CPR training. A model was developed using cardiac arrest and known demographic data from a single suburban zip code (population 36,325) including: local data (1997-1999) regarding cardiac arrest locations (public vs. private); incremental survival with CPR (historical survival rate 7.8%, adjusted odds ratio for CPR 2.0); arrest bystander demographics obtained from bystander telephone interviews; zip code demographics regarding population age and distribution; and 12.50 dollars per student for the cost of CPR training. Published rates of CPR training programs by age were used to estimate the numbers typically trained. Several assumptions were made: 1) there would be one bystander per. arrest; 2) the bystander would always perform CPR if trained; 3) cardiac arrest would be evenly distributed in the population; and 4) CPR training for a proportion of the population would proportionally increase CPR provision. Rates of arrest, bystanders by age, number of CPR trainees needed to result in increased arrest survival, and training cost per life saved for a one-year study period were calculated. There were 24.3 cardiac arrests per year, with 21.9 (90%) occurring in homes. In 66.5% of the home arrests, the bystander was more than 50 years old. To yield one additional survivor using the current CPR training strategy, 12,306 people needed to be trained (3,510 bystanders aged 50 years), which resulted in CPR provision to 7.14 additional patients. The training cost per life saved for a bystander aged 50 years was 785,040 dollars. Using a strategy of training only those cost of 53,383 dollars per life saved. Using these assumptions, current CPR training strategy is not a cost

  3. Comparison of Knowledge of Medical and Paramedical Intern about of CPR, 2015

    Directory of Open Access Journals (Sweden)

    Nastoor Bekhradian

    2016-09-01

    Full Text Available Every day a number of people from the heart stops beating for most of them that this early cessation of heartbeat. With operations of CPR in 4 to 6 minutes of cardiopulmonary arrest and before the onset of brain death can be established circulation and survival for patients with the death of 2 to 4 folds. The aim of this study was to Comparison of knowledge of medical and paramedical intern about of CPCR, 2015. This descriptive analytical and sampling method was census. Restore their data using a standard questionnaire with Cronbach's alpha coefficient was 0.82 .Spss20 data using statistical software analysis and descriptive statistics and Chi-square test was used. The mean score of 3/6 students that showed poor knowledge of students participating in the study. The lowest score of zero and the highest score was 12. Was found between gender and level of knowledge (p=0/05. Between education and the knowledge of the relationship was not statistically significant (p=0/764. The knowledge of medical and paramedical students groups scheduled for next semester as part of the treatment system personnel are working poor and require special attention in order to provide guidelines for planning authorities to increase the awareness of students.

  4. Incidence, characteristics, and survival following cardiopulmonary resuscitation in the quaternary neonatal intensive care unit.

    Science.gov (United States)

    Foglia, Elizabeth E; Langeveld, Robert; Heimall, Lauren; Deveney, Alyson; Ades, Anne; Jensen, Erik A; Nadkarni, Vinay M

    2017-01-01

    The contemporary characteristics and outcomes of cardiopulmonary resuscitation (CPR) in the neonatal intensive care unit (NICU) are poorly described. The objectives of this study were to determine the incidence, interventions, and outcomes of CPR in a quaternary referral NICU. Retrospective observational study of infants who received chest compressions for resuscitation in the Children's Hospital of Philadelphia NICU between April 1, 2011 and June 30, 2015. Patient, event, and survival characteristics were abstracted from the medical record and the hospital-wide resuscitation database. The primary outcome was survival to hospital discharge. Univariable and multivariable analyses were performed to identify patient and event factors associated with survival to discharge. There were 1.2 CPR events per 1000 patient days. CPR was performed in 113 of 5046 (2.2%) infants admitted to the NICU during the study period. The median duration of chest compressions was 2min (interquartile range 1, 6min). Adrenaline was administered in 34 (30%) CPR events. Of 113 infants with at least one CPR event, 69 (61%) survived to hospital discharge. Factors independently associated with decreased survival to hospital discharge were inotrope treatment prior to CPR (adjusted Odds Ratio [aOR] 0.14, 95% Confidence Interval [CI] 0.04, 0.54), and adrenaline administration during CPR (aOR 0.14, 95% CI 0.04, 0.50). Although it was not uncommon, the incidence of CPR was low (CPR and adrenaline administration during CPR were less likely to survive to hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Dynamically Polarized Sample for Neutron Scattering At the Spallation Neutron Source

    International Nuclear Information System (INIS)

    Pierce, Josh; Zhao, J. K.; Crabb, Don

    2009-01-01

    The recently constructed Spallation Neutron Source at the Oak Ridge National Laboratory is quickly becoming the world's leader in neutron scattering sciences. In addition to the world's most intense pulsed neutron source, we are continuously constructing state of the art neutron scattering instruments as well as sample environments to address today and tomorrow's challenges in materials research. The Dynamically Polarized Sample project at the SNS is aimed at taking maximum advantage of polarized neutron scattering from polarized samples, especially biological samples that are abundant in hydrogen. Polarized neutron scattering will allow us drastically increase the signal to noise ratio in experiments such as neutron protein crystallography. The DPS project is near completion and all key components have been tested. Here we report the current status of the project.

  6. Neutron polarization in polarized 3He targets

    International Nuclear Information System (INIS)

    Friar, J.L.; Gibson, B.F.; Payne, G.L.; Bernstein, A.M.; Chupp, T.E.

    1990-01-01

    Simple formulas for the neutron and proton polarizations in polarized 3 He targets are derived assuming (1) quasielastic final states; (2) no final-state interactions; (3) no meson-exchange currents; (4) large momentum transfers; (5) factorizability of 3 He SU(4) response-function components. Numerical results from a wide variety of bound-state solutions of the Faddeev equations are presented. It is found that this simple model predicts the polarization of neutrons in a fully polarized 3 He target to be 87%, while protons should have a slight residual polarization of -2.7%. Numerical studies show that this model works very well for quasielastic electron scattering

  7. Determination of beam polarization from integrated Borrmann intensities

    International Nuclear Information System (INIS)

    Staudenmann, J.L.; Horning, R.D.; Murphy, W.J.; Chapman, L.D.; Liedl, G.L.

    1986-01-01

    The Borrmann effect can be used to determine the extent of beam polarization of any x-ray beam. The method is applicable, without any modification, to any diffractometer equipped with a partial or full Eulerian cradle. It consists of rocking a perfect crystal, in a thick crystal Laue transmission geometry, through the Bragg angle at various values of the azimuthal angle /sub chi/. If the thickness of the perfect crystal is such that μT/sub 0/>10, then it measures directly the polarization of the incident beam. Three different Ge perfect crystals were used to study the amount of polarization of x-rays produced by a MO and a W source, followed by a double crystal graphite monochromator. A 180 0 periodicity in the integrated intensity, as a function of /sub chi/, is observed; the periodic extremes show the extent of beam polarization. Anomalously transmitted integrated intensity ratios between parallel (σ-component) and perpendicular (π-component) scanning directions, with respect to the scattering plane, are used to characterize the polarization since they are quite insensitive to beam divergences, whereas the corresponding peak height radius show very important beam divergence effects. Also, the polarization properties of graphite monochromators can be related to those of a perfect crystal if the (002) lattice planes are used for any excitation line of the W-anode. This is due to the polarization contribution of the intense white radiation spectrum superimposed on that of the line. On the other hand, the same spectrum impinging on the (004) lattice planes produce polarization properties closer to that of the ideally mosaic crystal

  8. Inkjet printed circularly polarized antennas for GPS applications

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2014-01-01

    gain of 0.2 dBi at 1.575 GHz with 3-dB axial ratio bandwidth of 3.8%. The second antenna design comprises a modified monopole in the form of an inverted L and has been termed as circularly polarized inverted L antenna (CILA). The antenna shows a gain

  9. Rates of cardiopulmonary resuscitation training in the United States.

    Science.gov (United States)

    Anderson, Monique L; Cox, Margueritte; Al-Khatib, Sana M; Nichol, Graham; Thomas, Kevin L; Chan, Paul S; Saha-Chaudhuri, Paramita; Fosbol, Emil L; Eigel, Brian; Clendenen, Bill; Peterson, Eric D

    2014-02-01

    Prompt bystander cardiopulmonary resuscitation (CPR) improves the likelihood of surviving an out-of-hospital cardiac arrest. Large regional variations in survival after an out-of-hospital cardiac arrest have been noted. To determine whether regional variations in county-level rates of CPR training exist across the United States and the factors associated with low rates in US counties. We used a cross-sectional ecologic study design to analyze county-level rates of CPR training in all US counties from July 1, 2010, through June 30, 2011. We used CPR training data from the American Heart Association, the American Red Cross, and the Health & Safety Institute. Using multivariable logistic regression models, we examined the association of annual rates of adult CPR training of citizens by these 3 organizations (categorized as tertiles) with a county's geographic, population, and health care characteristics. Completion of CPR training. Rate of CPR training measured as CPR course completion cards distributed and CPR training products sold by the American Heart Association, persons trained in CPR by the American Red Cross, and product sales data from the Health & Safety Institute. RESULTS During the study period, 13.1 million persons in 3143 US counties received CPR training. Rates of county training ranged from 0.00% to less than 1.29% (median, 0.51%) in the lower tertile, 1.29% to 4.07% (median, 2.39%) in the middle tertile, and greater than 4.07% or greater (median, 6.81%) in the upper tertile. Counties with rates of CPR training in the lower tertile were more likely to have a higher proportion of rural areas (adjusted odds ratio, 1.12 [95% CI, 1.10-1.15] per 5-percentage point [PP] change), higher proportions of black (1.09 [1.06-1.13] per 5-PP change) and Hispanic (1.06 [1.02-1.11] per 5-PP change) residents, a lower median household income (1.18 [1.04-1.34] per $10 000 decrease), and a higher median age (1.28 [1.04-1.58] per 10-year change). Counties in the South

  10. When measured spin polarization is not spin polarization

    International Nuclear Information System (INIS)

    Dowben, P A; Wu Ning; Binek, Christian

    2011-01-01

    Spin polarization is an unusually ambiguous scientific idiom and, as such, is rarely well defined. A given experimental methodology may allow one to quantify a spin polarization but only in its particular context. As one might expect, these ambiguities sometimes give rise to inappropriate interpretations when comparing the spin polarizations determined through different methods. The spin polarization of CrO 2 and Cr 2 O 3 illustrate some of the complications which hinders comparisons of spin polarization values. (viewpoint)

  11. An efficient source of continuous variable polarization entanglement

    International Nuclear Information System (INIS)

    Dong Ruifang; Heersink, Joel; Yoshikawa, Jun-Ichi; Gloeckl, Oliver; Andersen, Ulrik L; Leuchs, Gerd

    2007-01-01

    We have experimentally demonstrated the efficient creation of highly entangled bipartite continuous variable polarization states. Exploiting an optimized scheme for the production of squeezing using the Kerr non-linearity of a glass fibre we generated polarization squeezed pulses with a mean classical excitation in S-hat 3 . Polarization entanglement was generated by interfering two independent polarization squeezed fields on a symmetric beam splitter. The resultant beams exhibit strong quantum noise correlations in the dark S-hat 1 - S-hat 2 polarization plane. To verify entanglement generation, we characterized the quantum correlations of the system for two different sets of conjugate Stokes parameters. The quantum correlations along the squeezed and the anti-squeezed Stokes parameters were observed to be -4.1±0.3 and -2.6±0.3 dB below the shot noise level, respectively. The degree of correlations was found to depend critically on the beam-splitting ratio of the entangling beam splitter. Carrying out measurements on a different set of conjugate Stokes parameters, correlations of -3.6±0.3 and -3.4±0.3 dB have been observed. This result is more robust against asymmetries in the entangling beam splitter, even in the presence of excess noise

  12. A simple gold-coated microstructure fiber polarization filter in two communication windows

    Science.gov (United States)

    Feng, Xinxing; Li, Shuguang; Du, Huijing; Zhang, Yinan; Liu, Qiang

    2018-03-01

    A polarization filter is designed at two communication windows of 1310 and 1550 nm based on microstructured optical fiber. The model has four large diameter air holes and two gold-coated air holes. The influence of the geometrical parameters of the photonic crystal fiber on the performance of the polarization filter is analyzed by the finite element method. The numerical simulation shows that when the fiber length is 300 μm, the corresponding extinction ratio is 209.7 dB and 179.8 dB, the bandwidth of extinction ratio (ER) better than 20 dB is 150 nm and 350 nm at the communication wavelength of 1310 nm and 1550 nm.

  13. SUBMILLIMETER POLARIZATION SPECTRUM IN THE VELA C MOLECULAR CLOUD

    Energy Technology Data Exchange (ETDEWEB)

    Gandilo, Natalie N. [Department of Astronomy and Astrophysics, University of Toronto, 50 St. George Street Toronto, ON M5S 3H4 (Canada); Ade, Peter A. R.; Pascale, Enzo [Cardiff University, School of Physics and Astronomy, Queens Buildings, The Parade, Cardiff, CF24 3AA (United Kingdom); Angilè, Francesco E.; Devlin, Mark J.; Dober, Bradley; Galitzki, Nicholas; Klein, Jeffrey [Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA, 19104 (United States); Ashton, Peter; Fissel, Laura M.; Matthews, Tristan G.; Novak, Giles [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA) and Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208 (United States); Benton, Steven J. [Department of Physics, Princeton University, Jadwin Hall, Princeton, NJ 08544 (United States); Fukui, Yasuo [Department of Physics and Astrophysics, Nagoya University, Nagoya 464-8602 (Japan); Korotkov, Andrei L. [Department of Physics, Brown University, 182 Hope Street, Providence, RI, 02912 (United States); Li, Zhi-Yun [Department of Astronomy, University of Virginia, 530 McCormick Road, Charlottesville, VA 22904 (United States); Martin, Peter G. [CITA, University of Toronto, 60 St. George Street, Toronto, ON M5S 3H8 (Canada); Moncelsi, Lorenzo [California Institute of Technology, 1200 E. California Boulevard, Pasadena, CA, 91125 (United States); Nakamura, Fumitaka [National Astronomical Observatory, Mitaka, Tokyo 181-8588 (Japan); Netterfield, Calvin B., E-mail: ngandil1@jhu.edu [Department of Physics and Astronomy, Johns Hopkins University, 3701 San Martin Drive, Baltimore, Maryland (United States); and others

    2016-06-20

    Polarization maps of the Vela C molecular cloud were obtained at 250, 350, and 500 μ m during the 2012 flight of the balloon-borne telescope BLASTPol. These measurements are used in conjunction with 850 μ m data from Planck to study the submillimeter spectrum of the polarization fraction for this cloud. The spectrum is relatively flat and does not exhibit a pronounced minimum at λ ∼ 350 μ m as suggested by previous measurements of other molecular clouds. The shape of the spectrum does not depend strongly on the radiative environment of the dust, as quantified by the column density or the dust temperature obtained from Herschel data. The polarization ratios observed in Vela C are consistent with a model of a porous clumpy molecular cloud being uniformly heated by the interstellar radiation field.

  14. Room-Temperature Single-photon level Memory for Polarization States

    Science.gov (United States)

    Kupchak, Connor; Mittiga, Thomas; Jordaan, Bertus; Namazi, Mehdi; Nölleke, Christian; Figueroa, Eden

    2015-01-01

    An optical quantum memory is a stationary device that is capable of storing and recreating photonic qubits with a higher fidelity than any classical device. Thus far, these two requirements have been fulfilled for polarization qubits in systems based on cold atoms and cryogenically cooled crystals. Here, we report a room-temperature memory capable of storing arbitrary polarization qubits with a signal-to-background ratio higher than 1 and an average fidelity surpassing the classical benchmark for weak laser pulses containing 1.6 photons on average, without taking into account non-unitary operation. Our results demonstrate that a common vapor cell can reach the low background noise levels necessary for polarization qubit storage using single-photon level light, and propels atomic-vapor systems towards a level of functionality akin to other quantum information processing architectures.

  15. Two-photon polarization data storage in bacteriorhodopsin films and its potential use in security applications

    Energy Technology Data Exchange (ETDEWEB)

    Imhof, Martin; Hampp, Norbert, E-mail: hampp@staff.uni-marburg.de [Department of Chemistry, Material Sciences Center, University of Marburg, Hans-Meerwein-Str., D-35032 Marburg (Germany); Rhinow, Daniel [Max-Planck-Institute of Biophysics, Max-von-Laue-Straße 3, D-60438 Frankfurt (Germany)

    2014-02-24

    Bacteriorhodopsin (BR) films allow write-once-read-many recording of polarization data by a two-photon-absorption (TPA) process. The optical changes in BR films induced by the TPA recording were measured and the Müller matrix of a BR film was determined. A potential application of BR films in security technology is shown. Polarization data can be angle-selective retrieved with high signal-to-noise ratio. The BR film does not only carry optical information but serves also as a linear polarizer. This enables that polarization features recorded in BR films may be retrieved by merely using polarized light from a mobile phone display.

  16. Finite-Geometry and Polarized Multiple-Scattering Corrections of Experimental Fast- Neutron Polarization Data by Means of Monte Carlo Methods

    Energy Technology Data Exchange (ETDEWEB)

    Aspelund, O; Gustafsson, B

    1967-05-15

    After an introductory discussion of various methods for correction of experimental left-right ratios for polarized multiple-scattering and finite-geometry effects necessary and sufficient formulas for consistent tracking of polarization effects in successive scattering orders are derived. The simplifying assumptions are then made that the scattering is purely elastic and nuclear, and that in the description of the kinematics of the arbitrary Scattering {mu}, only one triple-parameter - the so-called spin rotation parameter {beta}{sup ({mu})} - is required. Based upon these formulas a general discussion of the importance of the correct inclusion of polarization effects in any scattering order is presented. Special attention is then paid to the question of depolarization of an already polarized beam. Subsequently, the afore-mentioned formulas are incorporated in the comprehensive Monte Carlo program MULTPOL, which has been designed so as to correctly account for finite-geometry effects in the sense that both the scattering sample and the detectors (both having cylindrical shapes) are objects of finite dimensions located at finite distances from each other and from the source of polarized fast-neutrons. A special feature of MULTPOL is the application of the method of correlated sampling for reduction of the standard deviations .of the results of the simulated experiment. Typical data of performance of MULTPOL have been obtained by the application of this program to the correction of experimental polarization data observed in n + '{sup 12}C elastic scattering between 1 and 2 MeV. Finally, in the concluding remarks the possible modification of MULTPOL to other experimental geometries is briefly discussed.

  17. Optimal design of DC-based polarization beam splitter in lithium niobate on insulator

    Science.gov (United States)

    Gong, Zisu; Yin, Rui; Ji, Wei; Wang, Junbao; Wu, Chonghao; Li, Xiao; Zhang, Shicheng

    2017-08-01

    We propose a DC-based polarization beam splitter (PBS) in lithium niobate on insulator (LNOI). Utilizing the high birefringence property of Lithium Niobate (LiNbO3, LN), the device is achieved by simple structure in a short length. With the use of beam propagation method (BPM), the simulation results show that the device has a good performance for the separation of TE and TM polarizations with a high extinction ratio (about 35 dB). The simulated fabrication tolerance for the variation of the waveguide width is about 100 nm and the bandwidth is about 65 nm when the extinction ratio is higher than 10 dB.

  18. Room Temperature Memory for Few Photon Polarization Qubits

    Science.gov (United States)

    Kupchak, Connor; Mittiga, Thomas; Jordan, Bertus; Nazami, Mehdi; Nolleke, Christian; Figueroa, Eden

    2014-05-01

    We have developed a room temperature quantum memory device based on Electromagnetically Induced Transparency capable of reliably storing and retrieving polarization qubits on the few photon level. Our system is realized in a vapor of 87Rb atoms utilizing a Λ-type energy level scheme. We create a dual-rail storage scheme mediated by an intense control field to allow storage and retrieval of any arbitrary polarization state. Upon retrieval, we employ a filtering system to sufficiently remove the strong pump field, and subject retrieved light states to polarization tomography. To date, our system has produced signal-to-noise ratios near unity with a memory fidelity of >80 % using coherent state qubits containing four photons on average. Our results thus demonstrate the feasibility of room temperature systems for the storage of single-photon-level photonic qubits. Such room temperature systems will be attractive for future long distance quantum communication schemes.

  19. FULLPROF as a new tool for flipping ratio analysis: further improvements

    International Nuclear Information System (INIS)

    Frontera, C.; Rodriguez-Carvajal, J.

    2004-01-01

    In the international workshop on polarized neutron for condensed matter investigation (Juelich, September 2002), we presented the implementations done in FULLPROF in order to introduce the ability of performing flipping ratio analysis. During this year we have modified the program in order to extend the initial features. We have tested these new implementations by re-analyzing flipping ratio data on Metrz-Nit (C 10 H 16 N 5 O 2 ) compound

  20. The O2 A-Band in the Fluxes and Polarization of Starlight Reflected by Earth-Like Exoplanets

    International Nuclear Information System (INIS)

    Fauchez, Thomas; Rossi, Loic; Stam, Daphne M.

    2017-01-01

    Earth-like, potentially habitable exoplanets are prime targets in the search for extraterrestrial life. Information about their atmospheres and surfaces can be derived by analyzing the light of the parent star reflected by the planet. We investigate the influence of the surface albedo A s , the optical thickness b cloud , the altitude of water clouds, and the mixing ratio of biosignature O 2 on the strength of the O 2 A-band (around 760 nm) in the flux and polarization spectra of starlight reflected by Earth-like exoplanets. Our computations for horizontally homogeneous planets show that small mixing ratios ( η < 0.4) will yield moderately deep bands in flux and moderate-to-small band strengths in polarization, and that clouds will usually decrease the band depth in flux and the band strength in polarization. However, cloud influence will be strongly dependent on properties such as optical thickness, top altitude, particle phase, coverage fraction, and horizontal distribution. Depending on the surface albedo and cloud properties, different O 2 mixing ratios η can give similar absorption-band depths in flux and band strengths in polarization, especially if the clouds have moderate-to-high optical thicknesses. Measuring both the flux and the polarization is essential to reduce the degeneracies, although it will not solve them, especially not for horizontally inhomogeneous planets. Observations at a wide range of phase angles and with a high temporal resolution could help to derive cloud properties and, once those are known, the mixing ratio of O 2 or any other absorbing gas.

  1. The HIP 79977 debris disk in polarized light

    Science.gov (United States)

    Engler, N.; Schmid, H. M.; Thalmann, Ch.; Boccaletti, A.; Bazzon, A.; Baruffolo, A.; Beuzit, J. L.; Claudi, R.; Costille, A.; Desidera, S.; Dohlen, K.; Dominik, C.; Feldt, M.; Fusco, T.; Ginski, C.; Gisler, D.; Girard, J. H.; Gratton, R.; Henning, T.; Hubin, N.; Janson, M.; Kasper, M.; Kral, Q.; Langlois, M.; Lagadec, E.; Ménard, F.; Meyer, M. R.; Milli, J.; Mouillet, D.; Olofsson, J.; Pavlov, A.; Pragt, J.; Puget, P.; Quanz, S. P.; Roelfsema, R.; Salasnich, B.; Siebenmorgen, R.; Sissa, E.; Suarez, M.; Szulagyi, J.; Turatto, M.; Udry, S.; Wildi, F.

    2017-11-01

    Context. Debris disks are observed around 10 to 20% of FGK main-sequence stars as infrared excess emission. They are important signposts for the presence of colliding planetesimals and therefore provide important information about the evolution of planetary systems. Direct imaging of such disks reveals their geometric structure and constrains their dust-particle properties. Aims: We present observations of the known edge-on debris disk around HIP 79977 (HD 146897) taken with the ZIMPOL differential polarimeter of the SPHERE instrument. We measure the observed polarization signal and investigate the diagnostic potential of such data with model simulations. Methods: SPHERE-ZIMPOL polarimetric data of the 15 Myr-old F star HIP 79977 (Upper Sco, 123 pc) were taken in the Very Broad Band (VBB) filter (λc = 735 nm, Δλ = 290 nm) with a spatial resolution of about 25 mas. Imaging polarimetry efficiently suppresses the residual speckle noise from the AO system and provides a differential signal with relatively small systematic measuring uncertainties. We measure the polarization flux along and perpendicular to the disk spine of the highly inclined disk for projected separations between 0.2'' (25 AU) and 1.6'' (200 AU). We perform model calculations for the polarized flux of an optically thin debris disk which are used to determine or constrain the disk parameters of HIP 79977. Results: We measure a polarized flux contrast ratio for the disk of (Fpol)disk/F∗ = (5.5 ± 0.9) × 10-4 in the VBB filter. The surface brightness of the polarized flux reaches a maximum of SBmax = 16.2 mag arcsec-2 at a separation of 0.2''-0.5'' along the disk spine with a maximum surface brightness contrast of 7.64 mag arcsec-2. The polarized flux has a minimum near the star 1''. This can be explained by a radial blow-out of small grains. The data are modelled as a circular dust belt with a well defined disk inclination I = 85( ± 1.5)° and a radius between r0 = 60 and 90 AU. The radial

  2. Metallic stereostructured layer: An approach for broadband polarization state manipulation

    International Nuclear Information System (INIS)

    Xiong, Xiang; Hu, Yuan-Sheng; Jiang, Shang-Chi; Hu, Yu-Hui; Fan, Ren-Hao; Ma, Guo-Bin; Shu, Da-Jun; Peng, Ru-Wen; Wang, Mu

    2014-01-01

    In this letter, we report a full-metallic broadband wave plate assembled by standing metallic L-shaped stereostructures (LSSs). We show that with an array of LSSs, high polarization conversion ratio is achieved within a broad frequency band. Moreover, by rotating the orientation of the array of LSSs, the electric components of the reflection beam in two orthogonal directions and their phase difference can be independently tuned. In this way, all the polarization states on the Poincaré sphere can be realized. As examples, the functionalities of a quarter wave plate and a half wave plate are experimentally demonstrated with both reflection spectra and focal-plane-array imaging. Our designing provides a unique approach in realizing the broadband wave plate to manipulate the polarization state of light

  3. Research on generating various polarization-modes in polarized illumination system

    Science.gov (United States)

    Huang, Jinping; Lin, Wumei; Fan, Zhenjie

    2013-08-01

    With the increase of the numerical aperture (NA), the polarization of light affects the imaging quality of projection lens more significantly. On the contrary, according to the mask pattern, the resolution of projection lens can be improved by using the polarized illumination. That is to say, using the corresponding polarized beam (or polarization-mode) along with the off-axis illumination will improve the resolution and the imaging quality of the of projection lens. Therefore, the research on the generation of various polarization modes and its conversion methods become more and more important. In order to realize various polarization modes in polarized illumination system, after read a lot of references, we provide a way that fitting for the illumination system with the wavelength of 193nm.Six polarization-modes and a depolarized mode are probably considered. Wave-plate stack is used to generate linearly polarization-mode, which have a higher degree polarization. In order to generate X-Y and Y-X polarization mode, the equipment consisting of four sectors of λ/2 wave plate was used. We combined 16 sectors of λ/2 wave plate which have different orientations of the "slow" axis to generate radial and azimuthal polarization. Finally, a multi-polarization control device was designed. Using the kind of multi-polarization control device which applying this method could help to choose the polarization modes conveniently and flexibility for the illumination system.

  4. Polarization properties of linearly polarized parabolic scaling Bessel beams

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Mengwen; Zhao, Daomu, E-mail: zhaodaomu@yahoo.com

    2016-10-07

    The intensity profiles for the dominant polarization, cross polarization, and longitudinal components of modified parabolic scaling Bessel beams with linear polarization are investigated theoretically. The transverse intensity distributions of the three electric components are intimately connected to the topological charge. In particular, the intensity patterns of the cross polarization and longitudinal components near the apodization plane reflect the sign of the topological charge. - Highlights: • We investigated the polarization properties of modified parabolic scaling Bessel beams with linear polarization. • We studied the evolution of transverse intensity profiles for the three components of these beams. • The intensity patterns of the cross polarization and longitudinal components can reflect the sign of the topological charge.

  5. Polarization in Raman spectroscopy helps explain bone brittleness in genetic mouse models

    Science.gov (United States)

    Makowski, Alexander J.; Pence, Isaac J.; Uppuganti, Sasidhar; Zein-Sabatto, Ahbid; Huszagh, Meredith C.; Mahadevan-Jansen, Anita; Nyman, Jeffry S.

    2014-11-01

    Raman spectroscopy (RS) has been extensively used to characterize bone composition. However, the link between bone biomechanics and RS measures is not well established. Here, we leveraged the sensitivity of RS polarization to organization, thereby assessing whether RS can explain differences in bone toughness in genetic mouse models for which traditional RS peak ratios are not informative. In the selected mutant mice-activating transcription factor 4 (ATF4) or matrix metalloproteinase 9 (MMP9) knock-outs-toughness is reduced but differences in bone strength do not exist between knock-out and corresponding wild-type controls. To incorporate differences in the RS of bone occurring at peak shoulders, a multivariate approach was used. Full spectrum principal components analysis of two paired, orthogonal bone orientations (relative to laser polarization) improved genotype classification and correlation to bone toughness when compared to traditional peak ratios. When applied to femurs from wild-type mice at 8 and 20 weeks of age, the principal components of orthogonal bone orientations improved age classification but not the explanation of the maturation-related increase in strength. Overall, increasing polarization information by collecting spectra from two bone orientations improves the ability of multivariate RS to explain variance in bone toughness, likely due to polarization sensitivity to organizational changes in both mineral and collagen.

  6. NMR investigations of surfaces and interfaces using spin-polarized xenon

    International Nuclear Information System (INIS)

    Gaede, H.C.; Lawrence Berkeley Lab., CA

    1995-07-01

    129 Xe NMR is potentially useful for the investigation of material surfaces, but has been limited to high surface area samples in which sufficient xenon can be loaded to achieve acceptable signal to noise ratios. In Chapter 2 conventional 129 Xe NMR is used to study a high surface area polymer, a catalyst, and a confined liquid crystal to determine the topology of these systems. Further information about the spatial proximity of different sites of the catalyst and liquid crystal systems is determined through two dimensional exchange NMR in Chapter 3. Lower surface area systems may be investigated with spin-polarized xenon, which may be achieved through optical pumping and spin exchange. Optically polarized xenon can be up to 10 5 times more sensitive than thermally polarized xenon. In Chapter 4 highly polarized xenon is used to examine the surface of poly(acrylonitrile) and the formation of xenon clathrate hydrates. An attractive use of polarized xenon is as a magnetization source in cross polarization experiments. Cross polarization from adsorbed polarized xenon may allow detection of surface nuclei with drastic enhancements. A non-selective low field thermal mixing technique is used to enhance the 13 C signal of CO 2 of xenon occluded in solid CO 2 by a factor of 200. High-field cross polarization from xenon to proton on the surface of high surface area polymers has enabled signal enhancements of ∼1,000. These studies, together with investigations of the efficiency of the cross polarization process from polarized xenon, are discussed in Chapter 5. Another use of polarized xenon is as an imaging contrast agent in systems that are not compatible with traditional contrast agents. The resolution attainable with this method is determined through images of structured phantoms in Chapter 6

  7. Polarization phenomena in quantum chromodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Brodsky, S.J. [Stanford Univ., CA (United States)

    1994-12-01

    The author discusses a number of interrelated hadronic spin effects which test fundamental features of perturbative and nonperturbative QCD. For example, the anomalous magnetic moment of the proton and the axial coupling g{sub A} on the nucleon are shown to be related to each other for fixed proton radius, independent of the form of the underlying three-quark relativistic quark wavefunction. The renormalization scale and scheme ambiguities for the radiative corrections to the Bjorken sum rule for the polarized structure functions can be eliminated by using commensurate scale relations with other observables. Other examples include (a) new constraints on the shape and normalization of the polarized quark and gluon structure functions of the proton at large and small x{sub bj}; (b) consequences of the principle of hadron retention in high x{sub F} inclusive reactions; (c) applications of hadron helicity conservation to high momentum transfer exclusive reactions; and (d) the dependence of nuclear structure functions and shadowing on virtual photon polarization. The author also discusses the implications of a number of measurements which are in striking conflict with leading-twist perturbative QCD predictions, such as the extraordinarily large spin correlation A{sub NN} observed in large angle proton-proton scattering, the anomalously large {rho}{pi} branching ratio of the J/{psi}, and the rapidly changing polarization dependence of both J/{psi} and continuum lepton pair hadroproduction observed at large x{sub F}. The azimuthal angular dependence of the Drell-Yan process is shown to be highly sensitive to the projectile distribution amplitude, the fundamental valence light-cone wavefunction of the hadron.

  8. Polarization phenomena in quantum chromodynamics

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1994-03-01

    The author discusses a number of interrelated hadronic spin effects which test fundamental features of perturbative and non-perturbative QCD. For example, the anomalous magnetic moment of the proton and the axial coupling g A on the nucleon are shown to be related to each other for fixed proton radius, independent of the form of the underlying three-quark relativistic quark wavefunction. The renormalization scale and scheme ambiguities for the radiative corrections to the Bjorken sum rule for the polarized structure functions can be eliminated by using commensurate scale relations with other observables. Other examples include (a) new constraints on the shape and normalization of the polarized quark and gluon structure functions of the proton at large and small x bj ; (b) consequences of the principle of hadron helicity retention in high x F inclusive reactions; (c) applications of hadron helicity conservation to high momentum transfer exclusive reactions; and (d) the dependence of nuclear structure functions and shadowing on virtual photon polarization. He also discusses the implications of a number of measurements which are in striking conflict with leading-twist perturbative QCD predictions, such as the extraordinarily large spin correlation A NN observed in large angle proton-proton scattering, the anomalously large ρπ branching ratio of the J/ψ, and the rapidly changing polarization dependence of both J/ψ and continuum lepton pair hadroproduction observed at large x F . The azimuthal angular dependence of the Drell-Yan process is shown to be highly sensitive to the projectile distribution amplitude, the fundamental valence light-cone wavefunction of the hadron

  9. Detection of ULF electromagnetic emissions as a precursor to an earthquake in China with an improved polarization analysis

    Directory of Open Access Journals (Sweden)

    Y. Ida

    2008-07-01

    Full Text Available An improved analysis of polarization (as the ratio of vertical magnetic field component to the horizontal one has been developed, and applied to the approximately four years data (from 1 March 2003 to 31 December 2006 observed at Kashi station in China. It is concluded that the polarization ratio has exhibited an apparent increase only just before the earthquake on 1 September 2003 (magnitude = 6.1 and epicentral distance of 116 km.

  10. Polarized nuclear target based on parahydrogen induced polarization

    OpenAIRE

    Budker, D.; Ledbetter, M. P.; Appelt, S.; Bouchard, L. S.; Wojtsekhowski, B.

    2012-01-01

    We discuss a novel concept of a polarized nuclear target for accelerator fixed-target scattering experiments, which is based on parahydrogen induced polarization (PHIP). One may be able to reach a 33% free-proton polarization in the ethane molecule. The potential advantages of such a target include operation at zero magnetic field, fast ($\\sim$100 Hz) polarization reversal, and operation with large intensity of an electron beam.

  11. The design of instructional tools affects secondary school students' learning of cardiopulmonary resuscitation (CPR) in reciprocal peer learning: a randomized controlled trial.

    Science.gov (United States)

    Iserbyt, Peter; Byra, Mark

    2013-11-01

    Research investigating design effects of instructional tools for learning Basic Life Support (BLS) is almost non-existent. To demonstrate the design of instructional tools matter. The effect of spatial contiguity, a design principle stating that people learn more deeply when words and corresponding pictures are placed close (i.e., integrated) rather than far from each other on a page was investigated on task cards for learning Cardiopulmonary Resuscitation (CPR) during reciprocal peer learning. A randomized controlled trial. A total of 111 students (mean age: 13 years) constituting six intact classes learned BLS through reciprocal learning with task cards. Task cards combine a picture of the skill with written instructions about how to perform it. In each class, students were randomly assigned to the experimental group or the control. In the control, written instructions were placed under the picture on the task cards. In the experimental group, written instructions were placed close to the corresponding part of the picture on the task cards reflecting application of the spatial contiguity principle. One-way analysis of variance found significantly better performances in the experimental group for ventilation volumes (P=.03, ηp2=.10) and flow rates (P=.02, ηp2=.10). For chest compression depth, compression frequency, compressions with correct hand placement, and duty cycles no significant differences were found. This study shows that the design of instructional tools (i.e., task cards) affects student learning. Research-based design of learning tools can enhance BLS and CPR education. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. [Analysis of influencing factors of snow hyperspectral polarized reflections].

    Science.gov (United States)

    Sun, Zhong-Qiu; Zhao, Yun-Sheng; Yan, Guo-Qian; Ning, Yan-Ling; Zhong, Gui-Xin

    2010-02-01

    Due to the need of snow monitoring and the impact of the global change on the snow, on the basis of the traditional research on snow, starting from the perspective of multi-angle polarized reflectance, we analyzed the influencing factors of snow from the incidence zenith angles, the detection zenith angles, the detection azimuth angles, polarized angles, the density of snow, the degree of pollution, and the background of the undersurface. It was found that these factors affected the spectral reflectance values of the snow, and the effect of some factors on the polarization hyperspectral reflectance observation is more evident than in the vertical observation. Among these influencing factors, the pollution of snow leads to an obvious change in the snow reflectance spectrum curve, while other factors have little effect on the shape of the snow reflectance spectrum curve and mainly impact the reflection ratio of the snow. Snow reflectance polarization information has not only important theoretical significance, but also wide application prospect, and provides new ideas and methods for the quantitative research on snow using the remote sensing technology.

  13. RECOVERY OF LARGE ANGULAR SCALE CMB POLARIZATION FOR INSTRUMENTS EMPLOYING VARIABLE-DELAY POLARIZATION MODULATORS

    Energy Technology Data Exchange (ETDEWEB)

    Miller, N. J.; Marriage, T. A.; Appel, J. W.; Bennett, C. L.; Eimer, J.; Essinger-Hileman, T.; Harrington, K.; Rostem, K.; Watts, D. J. [Department of Physics and Astronomy, Johns Hopkins University, 3400 N. Charles St., Baltimore, MD 21218 (United States); Chuss, D. T. [Department of Physics, Villanova University, 800 E Lancaster, Villanova, PA 19085 (United States); Wollack, E. J.; Fixsen, D. J.; Moseley, S. H.; Switzer, E. R., E-mail: Nathan.J.Miller@nasa.gov [Observational Cosmology Laboratory, Code 665, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2016-02-20

    Variable-delay Polarization Modulators (VPMs) are currently being implemented in experiments designed to measure the polarization of the cosmic microwave background on large angular scales because of their capability for providing rapid, front-end polarization modulation and control over systematic errors. Despite the advantages provided by the VPM, it is important to identify and mitigate any time-varying effects that leak into the synchronously modulated component of the signal. In this paper, the effect of emission from a 300 K VPM on the system performance is considered and addressed. Though instrument design can greatly reduce the influence of modulated VPM emission, some residual modulated signal is expected. VPM emission is treated in the presence of rotational misalignments and temperature variation. Simulations of time-ordered data are used to evaluate the effect of these residual errors on the power spectrum. The analysis and modeling in this paper guides experimentalists on the critical aspects of observations using VPMs as front-end modulators. By implementing the characterizations and controls as described, front-end VPM modulation can be very powerful for mitigating 1/f noise in large angular scale polarimetric surveys. None of the systematic errors studied fundamentally limit the detection and characterization of B-modes on large scales for a tensor-to-scalar ratio of r = 0.01. Indeed, r < 0.01 is achievable with commensurately improved characterizations and controls.

  14. Polarization spectrum of supernova 1987A interpreted in terms of shape asymmetry

    Energy Technology Data Exchange (ETDEWEB)

    Jeffery, D J

    1987-10-01

    Polarimetry carried out on the type II supernova 1987A on 6 and 7 March 1987 showed variation in polarization across line profiles. This polarization structure is interpreted as arising from an asymmetric, homologously expanding, scattering atmosphere surrounding an asymmetric continuum-producing photosphere. Resonant scattering of radiation by ions in the atmosphere produces the line structure in the flux spectrum and polarizes the emergent radiation. The asymmetric shape of the atmosphere causes a non-zero net polarization. Sobolev-method radiative transfer calculations with axisymmetric oblate ellipsoidal models have been carried out to fit the observed data. The models are parameterized by the ratio of the symmetry axis to the perpendicular axis, c/a. The fits to the 1987A data indicate that (c/a) is approx. 0.6-0.8.

  15. Cylindrically polarized Bessel–Gauss beams

    International Nuclear Information System (INIS)

    Madhi, Daena; Aiello, Andrea; Ornigotti, Marco

    2015-01-01

    We present a study of radially and azimuthally polarized Bessel–Gauss (BG) beams in both the paraxial and nonparaxial regime. We discuss the validity of the paraxial approximation and the form of the nonparaxial corrections for BG beams. We show that independently on the ratio between the Bessel aperture cone angle ϑ 0 and the Gaussian beam divergence θ 0 , the nonparaxial corrections are alway very small and therefore negligible. The explicit expressions for the nonparaxial vector electric field components are also reported. (paper)

  16. Fusion of a polarized projectile with a polarized target

    International Nuclear Information System (INIS)

    Christley, J.A.; Johnson, R.C.; Thompson, I.J.

    1995-01-01

    The fusion cross sections for a polarized target with both unpolarized and polarized projectiles are studied. Expressions for the observables are given for the case when both nuclei are polarized. Calculations for fusion of an aligned 165 Ho target with 16 O and polarized 7 Li beams are presented

  17. Forecasting the Contribution of Polarized Extragalactic Radio Sources in CMB Observations

    Science.gov (United States)

    Puglisi, G.; Galluzzi, V.; Bonavera, L.; Gonzalez-Nuevo, J.; Lapi, A.; Massardi, M.; Perrotta, F.; Baccigalupi, C.; Celotti, A.; Danese, L.

    2018-05-01

    We combine the latest data sets obtained with different surveys to study the frequency dependence of polarized emission coming from extragalactic radio sources (ERS). We consider data over a very wide frequency range starting from 1.4 GHz up to 217 GHz. This range is particularly interesting since it overlaps the frequencies of the current and forthcoming cosmic microwave background (CMB) experiments. Current data suggest that at high radio frequencies (ν ≥ 20 GHz) the fractional polarization of ERS does not depend on the total flux density. Conversely, recent data sets indicate a moderate increase of polarization fraction as a function of frequency, physically motivated by the fact that Faraday depolarization is expected to be less relevant at high radio frequencies. We compute ERS number counts using updated models based on recent data, and we forecast the contribution of unresolved ERS in CMB polarization spectra. Given the expected sensitivities and the observational patch sizes of forthcoming CMB experiments, about ∼200 (up to ∼2000) polarized ERS are expected to be detected. Finally, we assess that polarized ERS can contaminate the cosmological B-mode polarization if the tensor-to-scalar ratio is <0.05 and they have to be robustly controlled to de-lens CMB B-modes at the arcminute angular scales.

  18. First measurement of the electric formfactor of the neutron in the exclusive quasielastic scattering of polarized electrons from polarized 3He

    International Nuclear Information System (INIS)

    Meyerhoff, M.; Eyl, D.; Frey, A.; Andresen, H.G.; Annand, J.R.M.; Aulenbacher, K.; Becker, J.; Blume-Werry, J.; Dombo, T.; Drescher, P.; Ducret, J.E.; Fischer, H.; Grabmayr, P.; Hall, S.; Hartmann, P.; Hehl, T.; Heil, W.; Hoffmann, J.; Kellie, J.D.; Klein, F.; Leduc, M.; Moeller, H.; Nachtigall, C.; Ostrick, M.; Otten, E.W.; Owens, R.O.; Pluetzer, S.; Reichert, E.; Rohe, D.; Schaefer, M.; Schearer, L.D.; Schmieden, H.; Steffens, K.; Surkau, R.; Walcher, T.

    1995-01-01

    A first measurement of the asymmetry in quasielastic scattering of longitudinally polarized electrons from a polarized 3 He gas target in coincidence with the knocked out neutron is reported. This measurement was made feasible by the cw beam of the 855 meV Mainz Microtron MAMI. It allows a determination of the electric formfactor of the neutron G n E independent of binding effects to first order. At bar Q 2 =0.31 (GeV/c) 2 two asymmetries bar A parallel (rvec S He parallel rvec q) and bar A perpendicular (rvec S He perpendicular rvec q) have been measured giving bar A parallel =(-7.40±0.73%) and bar A perpendicular =(0.89±0.30)%. The ratio bar A perpendicular /bar A parallel is independent of the absolute value of the electron and target polarization and yields G n E =0.035±0.012±0.005. copyright 1995 American Institute of Physics

  19. The O{sub 2} A-Band in the Fluxes and Polarization of Starlight Reflected by Earth-Like Exoplanets

    Energy Technology Data Exchange (ETDEWEB)

    Fauchez, Thomas [Laboratoire d’Optique Atmosphèrique (LOA), UMR 8518, Université Lille 1, Villeneuve d’Ascq (France); Rossi, Loic; Stam, Daphne M. [Faculty of Aerospace Engineering, Delft University of Technology, Kluyverweg 1, 2629 HS Delft (Netherlands)

    2017-06-10

    Earth-like, potentially habitable exoplanets are prime targets in the search for extraterrestrial life. Information about their atmospheres and surfaces can be derived by analyzing the light of the parent star reflected by the planet. We investigate the influence of the surface albedo A {sub s}, the optical thickness b {sub cloud}, the altitude of water clouds, and the mixing ratio of biosignature O{sub 2} on the strength of the O{sub 2} A-band (around 760 nm) in the flux and polarization spectra of starlight reflected by Earth-like exoplanets. Our computations for horizontally homogeneous planets show that small mixing ratios ( η < 0.4) will yield moderately deep bands in flux and moderate-to-small band strengths in polarization, and that clouds will usually decrease the band depth in flux and the band strength in polarization. However, cloud influence will be strongly dependent on properties such as optical thickness, top altitude, particle phase, coverage fraction, and horizontal distribution. Depending on the surface albedo and cloud properties, different O{sub 2} mixing ratios η can give similar absorption-band depths in flux and band strengths in polarization, especially if the clouds have moderate-to-high optical thicknesses. Measuring both the flux and the polarization is essential to reduce the degeneracies, although it will not solve them, especially not for horizontally inhomogeneous planets. Observations at a wide range of phase angles and with a high temporal resolution could help to derive cloud properties and, once those are known, the mixing ratio of O{sub 2} or any other absorbing gas.

  20. Transmission of Multilevel 60 Gbit/s Polarization Multiplexed RZ-D8PSK using only 10 Gbit/s equipment

    DEFF Research Database (Denmark)

    Jensen, Jesper Bevensee; Tokle, Torger; Peucheret, Christophe

    2007-01-01

    By combining differential 8-ary phase shift keying with polarization multiplexing, we present transmission of multilevel modulation with 6 bits per symbol through a 100 km fiber span with a receiver bit-error-ratio better than 10-9.......By combining differential 8-ary phase shift keying with polarization multiplexing, we present transmission of multilevel modulation with 6 bits per symbol through a 100 km fiber span with a receiver bit-error-ratio better than 10-9....

  1. Neonatal outcomes following extensive cardiopulmonary resuscitation in the delivery room for infants born at less than 33 weeks gestational age.

    Science.gov (United States)

    Soraisham, Amuchou Singh; Lodha, Abhay Kumar; Singhal, Nalini; Aziz, Khalid; Yang, Junmin; Lee, Shoo K; Shah, Prakesh S

    2014-02-01

    To examine the neonatal mortality and morbidity of infants born at CPR) immediately after birth. In this retrospective cohort study, we performed secondary analyses of data from infants born at Neonatal Network between January 2010 and December 2011. Infants were divided into two groups based on birth weight (neonatal morbidity and mortality compared using bivariate and multivariate analyses. Of the 8033 eligible infants, 419 (5.2%) received DR-CPR. For infants weighing CPR, whereas 3.4% (outborn: 9.6%, inborn: 2.2%) of those weighing ≥1000 g received DR-CPR. If infants received DR-CPR there was increased risk of mortality, bronchopulmonary dysplasia (BPD) and severe brain injury. Logistic regression analysis showed DR-CPR was associated with increased mortality (adjusted odds ratio [aOR]: 2.09, 95% CI [1.39, 3.14]) in infants born weighing CPR was associated with increased mortality (aOR: 7.16, 95% CI [3.88, 13.2]), severe brain injury (aOR: 3.08, 95% CI [1.82, 5.22]), BPD (aOR: 2.14, 95% CI [1.25, 3.65]), pneumothorax (aOR: 3.11, 95% CI [1.53, 6.31]) and intestinal perforation (aOR: 3.47, 95% CI [1.46, 8.24]). DR-CPR is associated with increased risk of mortality and morbidity especially in preterm infants born weighing ≥1000 g. Long-term neurodevelopmental follow up is warranted for these infants.

  2. A New Dual Circularly Polarized Feed Employing a Dielectric Cylinder-Loaded Circular Waveguide Open End Fed by Crossed Dipoles

    Directory of Open Access Journals (Sweden)

    Jae-Hoon Bang

    2016-01-01

    Full Text Available This paper presents a new dual circularly polarized feed that provides good axial ratio over wide angles and low cross-polarized radiation in backward direction. A circular waveguide open end is fed with two orthogonally polarized waves in phase quadrature by a pair of printed crossed dipoles and a compact connectorized quadrature hybrid coupler. The waveguide aperture is loaded with a dielectric cylinder to reduce the cross-polarization beyond 90 degrees off the boresight. The fabricated feed has, at 5.5 GHz, 6.33-dBic copolarized gain, 3-dB beamwidth of 106°, 10-dB beamwidth of 195°, 3-dB axial ratio beamwidth of 215°, maximum cross-polarized gain of −21.4 dBic, and 27-dB port isolation. The reflection coefficient of the feed is less than −10 dB at 4.99–6.09 GHz.

  3. Change detection in multi-temporal dual polarization Sentinel-1 data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Canty, Morton J.; Skriver, Henning

    2017-01-01

    Based on an omnibus likelihood ratio test statistic for the equality of several variance-covariance matrices following the complex Wishart distribution with an associated p-value and a factorization of this test statistic, change analysis in a time series of 19 multilook, dual polarization Sentin...

  4. Temporal variations in dispatcher-assisted and bystander-initiated resuscitation efforts.

    Science.gov (United States)

    Yamashita, Akira; Maeda, Tetsuo; Myojo, Yasuhiro; Wato, Yukihiro; Ohta, Keisuke; Inaba, Hideo

    2018-04-03

    To investigate temporal variations in dispatcher-assisted and bystander-initiated resuscitation efforts and their association with survival after bystander-witnessed out-of-hospital cardiac arrests (OHCAs). We retrospectively analyzed the neurologically favorable 1-month survival and the parameters related to dispatcher assisted cardiopulmonary resuscitation (DA-CPR) and bystander CPR (BCPR) for 227,524 OHCA patients between 2007 and 2013 in Japan. DA-CPR sensitivity for OHCAs, bystander's compliance to DA-CPR assessed by the proportion of bystanders who follow DA-CPR, and performance of BCPR measured by the rate of bystander-initiated CPR in patients without DA-CPR were calculated as indices of resuscitation efforts. Performance of BCPR was only similar to temporal variations in the survival (correlation between hourly paired values, R 2 =0.263, P=0.01): a lower survival rate (3.4% vs 4.2%) and performance of BCPR (23.1% vs 30.8%) during night-time (22:00-5:59) than during non-night-time. In subgroup analyses based on interaction tests, all three indices deteriorated during night-time when OHCAs were witnessed by non-family (adjusted odds ratio, 0.73-0.82), particularly in non-elderly patients. The rate of public access defibrillation for these OHCAs markedly decreased during night-time (adjusted odds ratio, 0.49) with delayed emergency calls and BCPR initiation. Multivariable logistic regression analyses revealed that the survival rate of non-family-witnessed OHCAs was 1.83-fold lower during night-time than during non-night-time. Dispatcher-assisted and bystander-initiated resuscitation efforts are low during night-time in OHCAs witnessed by non-family. A divisional alert system to recruit well-trained individuals is needed in order to improve the outcomes of night-time OHCAs witnessed by non-family bystanders. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Surface chemistry and electronic structure of nonpolar and polar GaN films

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Monu; Krishna, T.C. Shibin; Aggarwal, Neha; Gupta, Govind, E-mail: govind@nplindia.org

    2015-08-01

    Highlights: • Surface chemistry and electronic structure of polar and nonpolar GaN is reported. • Influence of polarization on electron affinity of p & np GaN films is investigated. • Correlation between surface morphology and polarity has been deduced. - Abstract: Photoemission and microscopic analysis of nonpolar (a-GaN/r-Sapphire) and polar (c-GaN/c-Sapphire) epitaxial gallium nitride (GaN) films grown via RF-Molecular Beam Epitaxy is reported. The effect of polarization on surface properties like surface states, electronic structure, chemical bonding and morphology has been investigated and correlated. It was observed that polarization lead to shifts in core level (CL) as well as valence band (VB) spectra. Angle dependent X-ray Photoelectron Spectroscopic analysis revealed higher surface oxide in polar GaN film compared to nonpolar GaN film. On varying the take off angle (TOA) from 0° to 60°, the Ga−O/Ga−N ratio varied from 0.11–0.23 for nonpolar and 0.17–0.36 for polar GaN film. The nonpolar film exhibited N-face polarity while Ga-face polarity was perceived in polar GaN film due to the inherent polarization effect. Polarization charge compensated surface states were observed on the polar GaN film and resulted in downward band bending. Ultraviolet photoelectron spectroscopic measurements revealed electron affinity and ionization energy of 3.4 ± 0.1 eV and 6.8 ± 0.1 eV for nonpolar GaN film and 3.8 ± 0.1 eV and 7.2 ± 0.1 eV for polar GaN film respectively. Field Emission Scanning Electron Microscopy measurements divulged smooth morphology with pits on polar GaN film. The nonpolar film on the other hand showed pyramidal structures having facets all over the surface.

  6. Endotracheal Intubation Using the Macintosh Laryngoscope or KingVision Video Laryngoscope during Uninterrupted Chest Compression

    Directory of Open Access Journals (Sweden)

    Ewelina Gaszynska

    2014-01-01

    Full Text Available Objective. Advanced airway management, endotracheal intubation (ETI, during CPR is more difficult than, for example, during anesthesia. However, new devices such as video laryngoscopes should help in such circumstances. The aim of this study was to assess the performance of the KingVision video laryngoscopes in a manikin cardiopulmonary resuscitation (CPR scenario. Methods. Thirty students enrolled in the third year of paramedic school took part in the study. The simulated CPR scenario was ETI using the standard laryngoscope with a Macintosh blade (MCL and ETI using the KingVision video laryngoscope performed during uninterrupted chest compressions. The primary endpoints were the time needed for ETI and the success ratio. Results. The mean time required for intubation was similar for both laryngoscopes: 16.6 (SD 5.11, median 15.64, range 7.9–27.9 seconds versus 17.91 (SD 5.6, median 16.28, range 10.6–28.6 seconds for the MCL and KingVision, respectively (P=0.1888. On the first attempt at ETI, the success rate during CPR was comparable between the evaluated laryngoscopes: P=0.9032. Conclusion. The KingVision video laryngoscope proves to be less superior when used for endotracheal intubation during CPR compared to the standard laryngoscope with a Mackintosh blade. This proves true in terms of shortening the time needed for ETI and increasing the success ratio.

  7. Neutron polarization

    International Nuclear Information System (INIS)

    Firk, F.W.K.

    1976-01-01

    Some recent experiments involving polarized neutrons are discussed; they demonstrate how polarization studies provide information on fundamental aspects of nuclear structure that cannot be obtained from more traditional neutron studies. Until recently, neutron polarization studies tended to be limited either to very low energies or to restricted regions at higher energies, determined by the kinematics of favorable (p, vector n) and (d, vector n) reactions. With the advent of high intensity pulsed electron and proton accelerators and of beams of vector polarized deuterons, this is no longer the case. One has entered an era in which neutron polarization experiments are now being carried out, in a routine way, throughout the entire range from thermal energies to tens-of-MeV. The significance of neutron polarization studies is illustrated in discussions of a wide variety of experiments that include the measurement of T-invariance in the β-decay of polarized neutrons, a search for the effects of meson exchange currents in the photo-disintegration of the deuteron, the determination of quantum numbers of states in the fission of aligned 235 U and 237 Np induced by polarized neutrons, and the double- and triple-scattering of fast neutrons by light nuclei

  8. X-Parameter Based Modelling of Polar Modulated Power Amplifiers

    DEFF Research Database (Denmark)

    Wang, Yelin; Nielsen, Troels Studsgaard; Sira, Daniel

    2013-01-01

    X-parameters are developed as an extension of S-parameters capable of modelling non-linear devices driven by large signals. They are suitable for devices having only radio frequency (RF) and DC ports. In a polar power amplifier (PA), phase and envelope of the input modulated signal are applied...... at separate ports and the envelope port is neither an RF nor a DC port. As a result, X-parameters may fail to characterise the effect of the envelope port excitation and consequently the polar PA. This study introduces a solution to the problem for a commercial polar PA. In this solution, the RF-phase path...... PA for simulations. The simulated error vector magnitude (EVM) and adjacent channel power ratio (ACPR) were compared with the measured data to validate the model. The maximum differences between the simulated and measured EVM and ACPR are less than 2% point and 3 dB, respectively....

  9. Polarization difference due to nonrandomly oriented ice particles at millimeter/submillimeter waveband

    International Nuclear Information System (INIS)

    Xie Xinxin; Miao Jungang

    2011-01-01

    This paper presents polarized signature due to oriented circular columnar and planar ice crystals at millimeter/submillimeter (mm/sub-mm) waveband. DDSCAT 6.1 and RT4 code package are employed for scattering properties and radiative transfer simulations, respectively, at the three estimated window frequencies (150, 220 and 340 GHz) of FengYun-4 (FY-4). We use empirical formulas to describe realistic sizes of planar and columnar particles and assume that ice particles are in Gamma-size distribution in this study. A 'resonance' feature of polarized signals as a function of median mass diameter is notably found for horizontally oriented columns and blunt plates at the frequency of 340 GHz; however, there is no promising resonance characteristic for horizontally aligned plates with empirical sizes at the three window channels of FY-4. The position of the resonance peak is related to particle aspect ratio, frequency and ice water path (IWP), and it moves to a shorter median mass diameter when the particle aspect ratio decreases or IWP in clouds increases. Considering that particle canting angle distribution (Gaussian distribution in this study), polarization difference, as well as the brightness temperature difference between clear and cloudy sky, decreases rapidly when particles gradually change from horizontally oriented to randomly oriented. The upwelling brightness temperature is insensitive to particle size and shape but sensitive to particle orientation, the difference of brightness temperature between horizontal and random orientation up to 6 K, whereas polarized signature is quite sensitive to particle microphysics as well as orientation; polarized measurements thereby could benefit retrieval of cloud microphysical parameters.

  10. Three-photon polarization ququarts: polarization, entanglement and Schmidt decompositions

    International Nuclear Information System (INIS)

    Fedorov, M V; Miklin, N I

    2015-01-01

    We consider polarization states of three photons, propagating collinearly and having equal given frequencies but with arbitrary distributed horizontal or vertical polarizations of photons. A general form of such states is a superposition of four basic three-photon polarization modes, to be referred to as the three-photon polarization ququarts (TPPQ). All such states can be considered as consisting of one- and two-photon parts, which can be entangled with each other. The degrees of entanglement and polarization, as well as the Schmidt decomposition and Stokes vectors of TPPQ are found and discussed. (paper)

  11. Optimized fan-shaped chiral metamaterial as an ultrathin narrow-band circular polarizer at visible frequencies

    Science.gov (United States)

    He, Yizhuo; Wang, Xinghai; Ingram, Whitney; Ai, Bin; Zhao, Yiping

    2018-04-01

    Chiral metamaterials have the great ability to manipulate the circular polarizations of light, which can be utilized to build ultrathin circular polarizers. Here we build a narrow-band circular polarizer at visible frequencies based on plasmonic fan-shaped chiral nanostructures. In order to achieve the best optical performance, we systematically investigate how different fabrication factors affect the chiral optical response of the fan-shaped chiral nanostructures, including incident angle of vapor depositions, nanostructure thickness, and post-deposition annealing. The optimized fan-shaped nanostructures show two narrow bands for different circular polarizations with the maximum extinction ratios 7.5 and 6.9 located at wavelength 687 nm and 774 nm, respectively.

  12. Polarization splitter and polarization rotator designs based on transformation optics.

    Science.gov (United States)

    Kwon, Do-Hoon; Werner, Douglas H

    2008-11-10

    The transformation optics technique is employed in this paper to design two optical devices - a two-dimensional polarization splitter and a three-dimensional polarization rotator for propagating beams. The polarization splitter translates the TM- and the TE-polarized components of an incident beam in opposite directions (i.e., shifted up or shifted down). The polarization rotator rotates the polarization state of an incoming beam by an arbitrary angle. Both optical devices are reflectionless at the entry and exit interfaces. Design details and full-wave simulation results are provided.

  13. Tunable 13C/1H dual channel matching circuit for dynamic nuclear polarization system with cross-polarization

    DEFF Research Database (Denmark)

    Rybalko, Oleksandr; Bowen, Sean; Zhurbenko, Vitaliy

    2016-01-01

    In this paper we report initial results of design and practical implementation of tuning and matching circuit to estimate a performance of Dynamic Nuclear Polarization (DNP) at a magnetic field of 6.7 T. It is shown that developed circuit for signal observation is compact, easy to make and provides....... Measurement results with a tuning and matching circuit prototype are presented including obtained spectra (13C and 1H) and estimation of the signal-to-noise ratio....

  14. Financement agricole par l’échange grains / intrants : l’impact de la NPR à Sapezal–MT entre 2004 et 2009 Financiamento agrícola através da troca de grãos por insumos: o impacto da CPR em Sapezal-MT no período de 2004–2009 Agricultural financing through grain exchange for raw materials: the impact of CPR in Sapezal-MT in the 2004-2009 period

    Directory of Open Access Journals (Sweden)

    Wylmor Constantino Tives Dalfovo

    2011-11-01

    Full Text Available La NPR (Note de Produit Rural apparaît comme un instrument régulé par le Gouvernement Fédéral, grâce à laquelle le producteur anticipe sa recette de production en ayant comme contrepartie la remise aux entreprises privées d’une certaine quantité venue de sa production de soja. Ce système a pris de l'ampleur pendant la spirale inflationnaire et la crise fiscale brésilienne, durant les années 1980, qui a restreint le crédit. On a cherché dans cet article, ayant comme réference des entreprises de la commune de Sapezal – MT, à décrire les coûts d’acquisition des intrants à travers deux mécanismes distincts. Le premier, le mécanisme d’achat au comptant avec les prix des intrants obtenu en Reais, et le deuxième, le mécanisme à longue échéance connu comme NPR, où les prix ont été analysés sous le système d’échange contre des paquets d’intrants. Parmi les résultats, on a eu que la principale variable responsable du succès de la NPR est la variation du prix de la denrée à la période de réalisation du contrat et de son échéance. Autre résultat important, le fait que la majorité des producteurs que cherchent la NPR à Sapezal – MT ce sont les moyens producteurs. Enfin, quant aux agents financiers, les plus grandes entreprises occupent un pourcentage élevé de participation dans l’émission de ce type de négociation rurale.A CPR (Cédula de Produto Rural surge como um instrumento regulamentado pelo Governo Federal, em que o produtor antecipa sua receita de produção tendo como contrapartida a entrega para as empresas privadas de uma quantidade estipulada da sua produção de soja. Esse sistema ganhou força através da espiral inflacionária e da crise fiscal brasileira da década de 1980, que restringiu o crédito. Buscou-se nesse artigo, através de uma abordagem nas empresas do município de Sapezal-MT, descrever os custos de aquisição dos insumos através de dois mecanismos distintos. O

  15. Errors and corrections in the separation of spin-flip and non-spin-flip thermal neutron scattering using the polarization analysis technique

    International Nuclear Information System (INIS)

    Williams, W.G.

    1975-01-01

    The use of the polarization analysis technique to separate spin-flip from non-spin-flip thermal neutron scattering is especially important in determining magnetic scattering cross-sections. In order to identify a spin-flip ratio in the scattering with a particular scattering process, it is necessary to correct the experimentally observed 'flipping-ratio' to allow for the efficiencies of the vital instrument components (polarizers and spin-flippers), as well as multiple scattering effects in the sample. Analytical expressions for these corections are presented and their magnitudes in typical cases estimated. The errors in measurement depend strongly on the uncertainties in the calibration of the efficiencies of the polarizers and the spin-flipper. The final section is devoted to a discussion of polarization analysis instruments

  16. Design of a novel multi channel photonic crystal fiber polarization beam splitter

    Science.gov (United States)

    Zhao, Yunyan; Li, Shuguang; Wang, Xinyu; Wang, Guangyao; Shi, Min; Wu, Junjun

    2017-10-01

    A kind of multi channel dual-core photonic crystal fiber polarization beam splitter is designed. We analyze the effects of the lattice parameters and the thickness of gold layer on the beam splitting by the finite element method. Numerical results show that the thickness of metal layer and the size of the air holes near the fiber cores are closely linked with the nature of the polarization beam splitter. We also obtain that extinction ratio can reach -73.87 dB at 1 . 55 μm wavelength and at 1 . 41 μm, 1 . 65 μm extinction ratio can reach 30.8978 dB and 31.1741 dB, respectively. The comparison of the effect on the characteristic of the photonic crystal fiber with coating no gold is also taken into account.

  17. Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs.

    Science.gov (United States)

    Pytte, Morten; Kramer-Johansen, Jo; Eilevstjønn, Joar; Eriksen, Morten; Strømme, Taevje A; Godang, Kristin; Wik, Lars; Steen, Petter Andreas; Sunde, Kjetil

    2006-12-01

    Adrenaline (epinephrine) is used during cardiopulmonary resuscitation (CPR) based on animal experiments without supportive clinical data. Clinically CPR was reported recently to have much poorer quality than expected from international guidelines and what is generally done in laboratory experiments. We have studied the haemodynamic effects of adrenaline during CPR with good laboratory quality and with quality simulating clinical findings and the feasibility of monitoring these effects through VF waveform analysis. After 4 min of cardiac arrest, followed by 4 min of basic life support, 14 pigs were randomised to ClinicalCPR (intermittent manual chest compressions, compression-to-ventilation ratio 15:2, compression depth 30-38 mm) or LabCPR (continuous mechanical chest compressions, 12 ventilations/min, compression depth 45 mm). Adrenaline 0.02 mg/kg was administered 30 s thereafter. Plasma adrenaline concentration peaked earlier with LabCPR than with ClinicalCPR, median (range), 90 (30, 150) versus 150 (90, 270) s (p = 0.007), respectively. Coronary perfusion pressure (CPP) and cortical cerebral blood flow (CCBF) increased and femoral blood flow (FBF) decreased after adrenaline during LabCPR (mean differences (95% CI) CPP 17 (6, 29) mmHg (p = 0.01), FBF -5.0 (-8.8, -1.2) ml min(-1) (p = 0.02) and median difference CCBF 12% of baseline (p = 0.04)). There were no significant effects during ClinicalCPR (mean differences (95% CI) CPP 4.7 (-3.2, 13) mmHg (p = 0.2), FBF -0.2 (-4.6, 4.2) ml min(-1)(p = 0.9) and CCBF 3.6 (-1.8, 9.0)% of baseline (p = 0.15)). Slope VF waveform analysis reflected changes in CPP. Adrenaline improved haemodynamics during laboratory quality CPR in pigs, but not with quality simulating clinically reported CPR performance.

  18. Comparison of continuous compression with regular ventilations versus 30:2 compressions-ventilations strategy during mechanical cardiopulmonary resuscitation in a porcine model of cardiac arrest.

    Science.gov (United States)

    Yang, Zhengfei; Liu, Qingyu; Zheng, Guanghui; Liu, Zhifeng; Jiang, Longyuan; Lin, Qing; Chen, Rui; Tang, Wanchun

    2017-09-01

    A compression-ventilation (C:V) ratio of 30:2 is recommended for adult cardiopulmonary resuscitation (CPR) by the current American Heart Association (AHA) guidelines. However, continuous chest compression (CCC) is an alternative strategy for CPR that minimizes interruption especially when an advanced airway exists. In this study, we investigated the effects of 30:2 mechanical CPR when compared with CCC in combination with regular ventilation in a porcine model. Sixteen male domestic pigs weighing 39±2 kg were utilized. Ventricular fibrillation was induced and untreated for 7 min. The animals were then randomly assigned to receive CCC combined with regular ventilation (CCC group) or 30:2 CPR (VC group). Mechanical chest compression was implemented with a miniaturized mechanical chest compressor. At the same time of beginning of precordial compression, the animals were mechanically ventilated at a rate of 10 breaths-per-minute in the CCC group or with a 30:2 C:V ratio in the VC group. Defibrillation was delivered by a single 150 J shock after 5 min of CPR. If failed to resuscitation, CPR was resumed for 2 min before the next shock. The protocol was stopped if successful resuscitation or at a total of 15 min. The resuscitated animals were observed for 72 h. Coronary perfusion pressure, end-tidal carbon dioxide and carotid blood flow in the VC group were similar to those achieved in the CCC group during CPR. No significant differences were observed in arterial blood gas parameters between two groups at baseline, VF 6 min, CPR 4 min and 30, 120 and 360 min post-resuscitation. Although extravascular lung water index of both groups significantly increased after resuscitation, no distinct difference was found between CCC and VC groups. All animals were successfully resuscitated and survived for 72 h with favorable neurologic outcomes in both groups. However, obviously more numbers of rib fracture were observed in CCC animals in comparison with VC animals. There was no

  19. Polarization dynamics and polarization time of random three-dimensional electromagnetic fields

    International Nuclear Information System (INIS)

    Voipio, Timo; Setaelae, Tero; Shevchenko, Andriy; Friberg, Ari T.

    2010-01-01

    We investigate the polarization dynamics of random, stationary three-dimensional (3D) electromagnetic fields. For analyzing the time evolution of the instantaneous polarization state, two intensity-normalized polarization autocorrelation functions are introduced, one based on a geometric approach with the Poincare vectors and the other on energy considerations with the Jones vectors. Both approaches lead to the same conclusions on the rate and strength of the polarization dynamics and enable the definition of a polarization time over which the state of polarization remains essentially unchanged. For fields obeying Gaussian statistics, the two correlation functions are shown to be expressible in terms of quantities characterizing partial 3D polarization and electromagnetic coherence. The 3D degree of polarization is found to have the same meaning in the 3D polarization dynamics as the usual two-dimensional (2D) degree of polarization does with planar fields. The formalism is demonstrated with several examples, and it is expected to be useful in applications dealing with polarization fluctuations of 3D light.

  20. Polarization-maintaining, double-clad fiber amplifier employing externally applied stress-induced birefringence

    International Nuclear Information System (INIS)

    Koplow, Jeffrey P.; Goldberg, Lew; Moeller, Robert P.; Kliner, Dahv A. V.

    2000-01-01

    We report a new approach to obtaining linear-polarization operation of a rare-earth-doped fiber amplifier in which the gain fiber is coiled under tension to induce birefringence. We demonstrated this method by constructing an Er/Yb-doped, double-clad, single-mode fiber amplifier with an output power of 530 mW and a polarization extinction ratio of >17 dB (when seeded with linearly polarized light) at a wavelength of ∼1.5 μm . The technique is achromatic, permits single- or multiple-pass operation of the amplifier, requires no additional components in the optical path, leaves the fiber ends unobstructed, and is inexpensive to implement. (c) 2000 Optical Society of America

  1. Polar Coding for the Large Hadron Collider: Challenges in Code Concatenation

    CERN Document Server

    AUTHOR|(CDS)2238544; Podzorny, Tomasz; Uythoven, Jan

    2018-01-01

    In this work, we present a concatenated repetition-polar coding scheme that is aimed at applications requiring highly unbalanced unequal bit-error protection, such as the Beam Interlock System of the Large Hadron Collider at CERN. Even though this concatenation scheme is simple, it reveals significant challenges that may be encountered when designing a concatenated scheme that uses a polar code as an inner code, such as error correlation and unusual decision log-likelihood ratio distributions. We explain and analyze these challenges and we propose two ways to overcome them.

  2. Control of polarization and dipole moment in low-dimensional semiconductor nanostructures

    International Nuclear Information System (INIS)

    Li, L. H.; Ridha, P.; Mexis, M.; Smowton, P. M.; Blood, P.; Bozkurt, M.; Koenraad, P. M.; Patriarche, G.; Fiore, A.

    2009-01-01

    We demonstrate the control of polarization and dipole moment in semiconductor nanostructures, through nanoscale engineering of shape and composition. Rodlike nanostructures, elongated along the growth direction, are obtained by molecular beam epitaxial growth. By varying the aspect ratio and compositional contrast between the rod and the surrounding matrix, we rotate the polarization of the dominant interband transition from transverse-electric to transverse-magnetic, and modify the dipole moment producing a radical change in the voltage dependence of absorption spectra. This opens the way to the optimization of quantum dot amplifiers and electro-optical modulators.

  3. Wavelength Conversion of DP-QPSK Signals in a Silicon Polarization Diversity Circuit

    DEFF Research Database (Denmark)

    Vukovic, Dragana; Schroeder, Jochen; Ding, Yunhong

    2015-01-01

    Multichannel wavelength conversion is experimentally demonstrated for high-speed 128 Gb/s dual-polarization quadrature phase-shift keying signals using four-wave mixing in a polarization diversity circuit with silicon nanowires as nonlinear elements. The wavelength conversion performance is inves...... is investigated for both single-and three-channel input signals, showing quality factors well >9.8 dB (corresponding to bit-error-ratios better than 10(-3)) and with a negligible power penalty compared with the back-to-back case....

  4. Polarized electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Prepost, R. [Univ. of Wisconsin, Madison, WI (United States)

    1994-12-01

    The fundamentals of polarized electron sources are described with particular application to the Stanford Linear Accelerator Center. The SLAC polarized electron source is based on the principle of polarized photoemission from Gallium Arsenide. Recent developments using epitaxially grown, strained Gallium Arsenide cathodes have made it possible to obtain electron polarization significantly in excess of the conventional 50% polarization limit. The basic principles for Gallium and Arsenide polarized photoemitters are reviewed, and the extension of the basic technique to strained cathode structures is described. Results from laboratory measurements of strained photocathodes as well as operational results from the SLAC polarized source are presented.

  5. Polarized electron sources

    International Nuclear Information System (INIS)

    Prepost, R.

    1994-01-01

    The fundamentals of polarized electron sources are described with particular application to the Stanford Linear Accelerator Center. The SLAC polarized electron source is based on the principle of polarized photoemission from Gallium Arsenide. Recent developments using epitaxially grown, strained Gallium Arsenide cathodes have made it possible to obtain electron polarization significantly in excess of the conventional 50% polarization limit. The basic principles for Gallium and Arsenide polarized photoemitters are reviewed, and the extension of the basic technique to strained cathode structures is described. Results from laboratory measurements of strained photocathodes as well as operational results from the SLAC polarized source are presented

  6. Improving the quality of cardiopulmonary resuscitation by training dedicated cardiac arrest teams incorporating a mechanical load-distributing device at the emergency department.

    Science.gov (United States)

    Ong, Marcus Eng Hock; Quah, Joy Li Juan; Annathurai, Annitha; Noor, Noorkiah Mohamed; Koh, Zhi Xiong; Tan, Kenneth Boon Kiat; Pothiawala, Sohil; Poh, Ah Ho; Loy, Chye Khiaw; Fook-Chong, Stephanie

    2013-04-01

    Determine if implementing cardiac arrest teams trained with a 'pit-crew' protocol incorporating a load-distributing band mechanical CPR device (Autopulse™ ZOLL) improves the quality of CPR, as determined by no-flow ratio (NFR) in the first 10min of resuscitation. A phased, prospective, non-randomized, before-after cohort evaluation. Data collection was from April 2008 to February 2011. There were 100 before and 148 after cases. Continuous video and chest compression data of all study subjects were analyzed. All non-traumatic, collapsed patients aged 18 years and above presenting to the emergency department were eligible. Primary outcome was NFR. Secondary outcomes were return of spontaneous circulation (ROSC), survival to hospital admission and neurological outcome at discharge. After implementation, mean total NFR for the first 5min decreased from 0.42 to 0.27 (decrease=0.15, 95% CI 0.10-0.19, pCPR ratio increased from 46.4% to 88.4% (increase=41.9%, 95% CI 36.9-46.9, pTraining cardiac arrest teams in a 'pit-crew' protocol may improve the quality of CPR at the ED. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Broadband non-polarizing beam splitter based on guided mode resonance effect

    Science.gov (United States)

    Ma, Jian-Yong; Xu, Cheng; Qiang, Ying-Huai; Zhu, Ya-Bo

    2011-10-01

    A broadband non-polarizing beam splitter (NPBS) operating in the telecommunication C+L band is designed by using the guided mode resonance effect of periodic silicon-on-insulator (SOI) elements. It is shown that this double layer SOI structure can provide ~50/50 beam ratio with the maximum divergences between reflection and transmission being less than 8% over the spectrum of 1.4 μm~1.7 μm and 1% in the telecommunication band for both TE and TM polarizations. The physical basis of this broadband non-polarizing property is on the simultaneous excitation of the TE and TM strong modulation waveguide modes near the designed spectrum band. Meanwhile, the electric field distributions for both TE and TM polarizations verify the resonant origin of spectrum in the periodic SOI structure. Furthermore, it is demonstrated with our calculations that the beam splitter proposed here is tolerant to the deviations of incident angle and structure parameters, which make it very easy to be fabricated with current IC technology.

  8. W-Band Circularly Polarized TE11 Mode Transducer

    Science.gov (United States)

    Zhan, Mingzhou; He, Wangdong; Wang, Lei

    2018-06-01

    This paper presents a balanced sidewall exciting approach to realize the circularly polarized TE11 mode transducer. We used a voltage vector transfer matrix to establish the relationship between input and output vectors, then we analyzed amplitude and phase errors to estimate the isolation of degenerate mode. A mode transducer with a sidewall exciter was designed based on the results. In the 88-100 GHz frequency range, the simulated axial ratio is less than 1.05 and the isolation of linearly polarization TE11 mode is higher than 30 dBc. In back-to-back measurements, the return loss is generally greater than 20 dB with a typical insertion loss of 1.2 dB. Back-to-back transmission measurements are in excellent agreement with simulations.

  9. Evaluation of knowledge of students in paediatric dentistry concerning cardiopulmonary resuscitation skills in children.

    Science.gov (United States)

    De Mauro, L M; Oliveira, L B; Bergamaschi, C De Cássia; Ramacciato, J C; Motta, R H L

    2018-05-10

    The study evaluated the theoretical knowledge and practical ability of students in paediatric dentistry concerning basic life support (BLS) and cardiopulmonary resuscitation (CPR) in children and babies. Seventy paediatric dentistry students answered a questionnaire and also performed a simulation of the manoeuvres of BLS and CPR on baby and child manikins. The results showed that 41 (58%) students had never received BLS training. When questioned about the correct ratio of compression and ventilation during CPR, most students answered incorrectly. For the CPR of babies in the presence of a first responder only 19 (27.1%) answered correctly (30 × 2), and for babies with two rescuers, 23 (32.8%) answered correctly (15 × 2); in relation to the correct rhythm of chest compressions, 38 (54.4%) answered incorrectly; when asked if they felt prepared to deal with a medical emergency in their dental surgeries, only 12 (17.1%) stated "yes". In the practice evaluation, 51 (73%) students who had been assessed in CPR manoeuvres for children and 55 (78%) in the manoeuvres for babies scored inadequately. The evaluated students did not have adequate knowledge about CPR in children and babies.

  10. Promoting Diversity Through Polar Interdisciplinary Coordinated Education (Polar ICE)

    Science.gov (United States)

    McDonnell, J. D.; Hotaling, L. A.; Garza, C.; Van Dyk, P. B.; Hunter-thomson, K. I.; Middendorf, J.; Daniel, A.; Matsumoto, G. I.; Schofield, O.

    2017-12-01

    Polar Interdisciplinary Coordinated Education (ICE) is an education and outreach program designed to provide public access to the Antarctic and Arctic regions through polar data and interactions with the scientists. The program provides multi-faceted science communication training for early career scientists that consist of a face-to face workshop and opportunities to apply these skills. The key components of the scientist training workshop include cultural competency training, deconstructing/decoding science for non-expert audiences, the art of telling science stories, and networking with members of the education and outreach community and reflecting on communication skills. Scientists partner with educators to provide professional development for K-12 educators and support for student research symposia. Polar ICE has initiated a Polar Literacy initiative that provides both a grounding in big ideas in polar science and science communication training designed to underscore the importance of the Polar Regions to the public while promoting interdisciplinary collaborations between scientists and educators. Our ultimate objective is to promote STEM identity through professional development of scientists and educators while developing career awareness of STEM pathways in Polar science.

  11. Polarization-independent broadband meta-holograms via polarization-dependent nanoholes.

    Science.gov (United States)

    Zhang, Xiaohu; Li, Xiong; Jin, Jinjin; Pu, Mingbo; Ma, Xiaoliang; Luo, Jun; Guo, Yinghui; Wang, Changtao; Luo, Xiangang

    2018-05-17

    Composed of ultrathin metal or dielectric nanostructures, metasurfaces can manipulate the phase, amplitude and polarization of electromagnetic waves at a subwavelength scale, which is promising for flat optical devices. In general, metasurfaces composed of space-variant anisotropic units are sensitive to the incident polarization due to the inherent polarization dependent geometric phase. Here, we implement polarization-independent broadband metasurface holograms constructed by polarization-dependent anisotropic elliptical nanoholes by elaborate design of complex amplitude holograms. The fabricated meta-hologram exhibits a polarization insensitive feature with an acceptable image quality. We verify the feasibility of the design algorithm for three-dimensional (3D) meta-holograms with simulation and the feasibility for two-dimensional (2D) meta-holograms is experimentally demonstrated at a broadband wavelength range from 405 nm to 632.8 nm. The effective polarization-independent broadband complex wavefront control with anisotropic elliptical nanoholes proposed in this paper greatly promotes the practical applications of the metasurface in technologies associated with wavefront manipulation, such as flat lens, colorful holographic displays and optical storage.

  12. A high throughput liquid crystal light shutter for unpolarized light using polymer polarization gratings

    Science.gov (United States)

    Komanduri, Ravi K.; Lawler, Kris F.; Escuti, Michael J.

    2011-05-01

    We report on a broadband, diffractive, light shutter with the ability to modulate unpolarized light. This polarizer-free approach employs a conventional liquid crystal (LC) switch, combined with broadband Polarization Gratings (PGs) formed with polymer LC materials. The thin-film PGs act as diffractive polarizing beam-splitters, while the LC switch operates on both orthogonal polarization states simultaneously. As an initial experimental proof-of- concept for unpolarized light with +/-7° aperture, we utilize a commercial twisted-nematic LC switch and our own polymer PGs to achieve a peak transmittance of 80% and peak contrast ratio of 230:1. We characterize the optoelectronic performance, discuss the limitations, and evaluate its use in potential nonmechanical shutter applications (imaging and non-imaging).

  13. Polarization digital holographic microscopy using low-cost liquid crystal polarization rotators

    Science.gov (United States)

    Dovhaliuk, Rostyslav Yu

    2018-02-01

    Polarization imaging methods are actively used to study anisotropic objects. A number of methods and systems, such as imaging polarimeters, were proposed to measure the state of polarization of light that passed through the object. Digital holographic and interferometric approaches can be used to quantitatively measure both amplitude and phase of a wavefront. Using polarization modulation optics, the measurement capabilities of such interference-based systems can be extended to measure polarization-dependent parameters, such as phase retardation. Different kinds of polarization rotators can be used to alternate the polarization of a reference beam. Liquid crystals are used in a rapidly increasing number of different optoelectronic devices. Twisted nematic liquid crystals are widely used as amplitude modulators in electronic displays and light valves or shutter glass. Such devices are of particular interest for polarization imaging, as they can be used as polarization rotators, and due to large-scale manufacturing have relatively low cost. A simple Mach-Zehnder polarized holographic setup that uses modified shutter glass as a polarization rotator is demonstrated. The suggested approach is experimentally validated by measuring retardation of quarter-wave film.

  14. Terahertz polarizing beam splitter based on copper grating on polyimide substrate

    Science.gov (United States)

    Zhang, Mengen; Li, Xiangjun; Wang, Wentao; Liu, Jianjun; Hong, Zhi

    2012-12-01

    A terahertz polarizing beam splitter, based on a copper grating on polyimide (PI) substrate, was fabricated by the way of laser induced and non-electrolytic plating. The good polarization characteristics of the splitter in the range of 0°-180°polarization are verified experimentally using backward wave oscillator at fixed frequency of 300GHz, and the insertion losses of 0.13dB and 0.32dB are measured for the transmitted and reflected beams, respectively. The broadband transmission of TM wave of the splitter was also measured by terahertz time-domain spectroscopy, and the extinction ratio larger than 22dB is obtained in the frequency range of 0.2-1.5THz. The experiment results are in good agreement with finite element simulation results.

  15. Design of ultra compact polarization splitter based on complete photonic band gap

    Science.gov (United States)

    Sinha, R. K.; Nagpal, Yogita

    2005-11-01

    Certain select structures in photonic crystals (PhCs) exhibit complete photonic band gap i.e. a frequency region where the photonic band gaps for both polarizations (i.e. transverse electric and transverse magnetic modes) exist and overlap. One of the most fundamental applications of the photonic band gap structures is the design of photonic crystal waveguides, which can be made by inserting linear defects in the photonic crystal structures. By setting closely two parallel 2D PhC waveguides, a directional waveguide coupler can be designed, which can be used to design a polarization splitter. In this paper we design a polarization splitter in a photonic crystal structure composed of two dimensional honeycomb pattern of dielectric rods in air. This photonic crystal structure exhibits a complete photonic band gap that extends from λ = 1.49 μm to λ = 1.61 μm, where lambda is the wavelength in free space, providing a large bandwidth of 120 nm. A polarization splitter can be made by designing a polarization selective coupler. The coupling lengths at various wavelengths for both polarizations have been calculated using the Finite Difference Time Domain method. It has been shown that the coupling length, for TE polarization is much smaller as compared to that for the TM polarization. This principle is used to design a polarization splitter of length 32 μm at λ = 1.55 μm. Further, the spectral response of the extinction ratios for both polarizations in the two waveguides at propagation distance of 32 μm has been studied.

  16. Polarization holography

    DEFF Research Database (Denmark)

    Nikolova, L.; Ramanujam, P.S.

    Current research into holography is concerned with applications in optically storing, retrieving, and processing information. Polarization holography has many unique properties compared to conventional holography. It gives results in high efficiency, achromaticity, and special polarization...... properties. This books reviews the research carried out in this field over the last 15 years. The authors provide basic concepts in polarization and the propagation of light through anisotropic materials, before presenting a sound theoretical basis for polarization holography. The fabrication...... and characterization of azobenzene based materials, which remain the most efficient for the purpose, is described in detail. This is followed by a description of other materials that are used in polarization holography. An in-depth description of various applications, including display holography and optical storage...

  17. Fetal Doppler to predict cesarean delivery for non-reassuring fetal status in the severe small-for-gestational-age fetuses of late preterm and term.

    Science.gov (United States)

    Jo, Ji Hye; Choi, Yong Hee; Wie, Jeong Ha; Ko, Hyun Sun; Park, In Yang; Shin, Jong Chul

    2018-03-01

    To evaluate the significance of fetal Doppler parameters in predicting adverse neonatal outcomes and the risk of cesarean delivery due to non-reassuring fetal status, in severe small for gestational age (SGA) fetuses of late preterm and term gestation. Fetal brain and umbilical artery (UmA) Doppler parameters of cerebroplacental ratio (CPR) and UmA pulsatility index (PI) were evaluated in a cohort of 184 SGA fetuses between 34 and 41 weeks gestational age, who were less than the 5th percentile. The risks of neonatal morbidities and cesarean delivery due to non-reassuring fetal status were analyzed. Univariate analysis revealed that abnormal CPR was significantly associated with cesarean delivery due to non-reassuring fetal status ( P =0.018), but not with neonatal morbidities. However, abnormal CPR did not increase the risk of cesarean delivery due to non-reassuring fetal status in multivariate logistic regression analysis. Abnormal CPR with abnormal PI of UmA was associated with low Apgar score at 1 minute ( P =0.048), mechanical ventilation ( P =0.013) and cesarean delivery due to non-reassuring fetal status ( P cesarean delivery for non-reassuring fetal status (adjusted odds ratio, 7.0; 95% confidence interval, 1.2-41.3; P =0.033), but did not increase risk of low Apgar score or mechanical ventilation in multivariate logistic regression analysis. Abnormal CPR with abnormal PI of UmA increases the risk of cesarean delivery for non-reassuring fetal status, in severe SGA fetuses of late preterm and term. Monitoring of CPR and PI of UmA can help guide management including maternal hospitalization and fetal monitoring.

  18. Bystander Cardiopulmonary Resuscitation Is Clustered and Associated With Neighborhood Socioeconomic Characteristics: A Geospatial Analysis of Kent County, Michigan.

    Science.gov (United States)

    Uber, Amy; Sadler, Richard C; Chassee, Todd; Reynolds, Joshua C

    2017-08-01

    Geographic clustering of bystander cardiopulmonary resuscitation (CPR) is associated with demographic and socioeconomic features of the community where out-of-hospital cardiac arrest (OHCA) occurred, although this association remains largely untested in rural areas. With a significant rural component and relative racial homogeneity, Kent County, Michigan, provides a unique setting to externally validate or identify new community features associated with bystander CPR. Using a large, countywide data set, we tested for geographic clustering of bystander CPR and its associations with community socioeconomic features. Secondary analysis of adult OHCA subjects (2010-2015) in the Cardiac Arrest Registry to Enhance Survival (CARES) data set for Kent County, Michigan. After linking geocoded OHCA cases to U.S. census data, we used Moran's I-test to assess for spatial autocorrelation of population-weighted cardiac arrest rate by census block group. Getis-Ord Gi statistic assessed for spatial clustering of bystander CPR and mixed-effects hierarchical logistic regression estimated adjusted associations between community features and bystander CPR. Of 1,592 subjects, 1,465 met inclusion criteria. Geospatial analysis revealed significant clustering of OHCA in more populated/urban areas. Conversely, bystander CPR was less likely in these areas (99% confidence) and more likely in suburban and rural areas (99% confidence). Adjusting for clinical, demographic, and socioeconomic covariates, bystander CPR was associated with public location (odds ratio [OR] = 1.19; 95% confidence interval [CI] = 1.03-1.39), initially shockable rhythms (OR = 1.48; 95% CI = 1.12-1.96), and those in urban neighborhoods (OR = 0.54; 95% CI = 0.38-0.77). Out-of-hospital cardiac arrest and bystander CPR are geographically clustered in Kent County, Michigan, but bystander CPR is inversely associated with urban designation. These results offer new insight into bystander CPR patterns in mixed urban and rural

  19. Cardiopulmonary Resuscitation Training in Schools Following 8 Years of Mandating Legislation in Denmark: A Nationwide Survey.

    Science.gov (United States)

    Malta Hansen, Carolina; Zinckernagel, Line; Ersbøll, Annette Kjær; Tjørnhøj-Thomsen, Tine; Wissenberg, Mads; Lippert, Freddy Knudsen; Weeke, Peter; Gislason, Gunnar Hilmar; Køber, Lars; Torp-Pedersen, Christian; Folke, Fredrik

    2017-03-14

    School cardiopulmonary resuscitation (CPR) training has become mandatory in many countries, but whether legislation has translated into implementation of CPR training is largely unknown. We assessed CPR training of students following 8 years of legislative mandates in Denmark. A nationwide cross-sectional survey of Danish school leadership (n=1240) and ninth-grade homeroom teachers (n=1381) was carried out for school year 2013-2014. Qualitative interviews and the Theory of Planned Behavior were used to construct the survey. Logistic regression models were employed to identify factors associated with completed CPR training. Information from 63.1% of eligible schools was collected: 49.3% (n=611) of leadership and 48.2% (n=665) of teachers responded. According to teachers, 28.4% (95% CI 25.0% to 32.0%) and 10.3% (95% CI 8.1% to 12.8%) of eligible classes had completed CPR and automated external defibrillator training, respectively. Among leadership, 60.2% (95% CI 56.2% to 64.1%) reported CPR training had occurred during the 3 years prior to the survey. Factors associated with completed CPR training included believing other schools were conducting training (odds ratio [OR] 9.68 [95% CI 4.65-20.1]), awareness of mandating legislation (OR 4.19 [95% CI 2.65-6.62]), presence of a school CPR training coordinator (OR 3.01 [95% CI 1.84-4.92]), teacher feeling competent to conduct training (OR 2.78 [95% CI 1.74-4.45]), and having easy access to training material (OR 2.08 [95% CI 1.57-2.76]). Despite mandating legislation, school CPR training has not been successfully implemented. Completed CPR training was associated with believing other schools were conducting training, awareness of mandating legislation, presence of a school CPR training coordinator, teachers teacher feeling competent to conduct training, and having easy access to training material. Facilitating these factors may increase rates of school CPR training. © 2017 The Authors. Published on behalf of the

  20. A comparative study of defibrillation and cardiopulmonary resuscitation performance during simulated cardiac arrest in nursing student teams

    Directory of Open Access Journals (Sweden)

    Eikeland Husebø Sissel I

    2012-04-01

    Full Text Available Abstract Background Although nurses must be able to respond quickly and effectively to cardiac arrest, numerous studies have demonstrated poor performance. Simulation is a promising learning tool for resuscitation team training but there are few studies that examine simulation for training defibrillation and cardiopulmonary resuscitation (D-CPR in teams from the nursing education perspective. The aim of this study was to investigate the extent to which nursing student teams follow the D-CPR-algorithm in a simulated cardiac arrest, and if observing a simulated cardiac arrest scenario and participating in the post simulation debriefing would improve team performance. Methods We studied video-recorded simulations of D-CPR performance in 28 nursing student teams. Besides describing the overall performance of D-CPR, we compared D-CPR performance in two groups. Group A (n = 14 performed D-CPR in a simulated cardiac arrest scenario, while Group B (n = 14 performed D-CPR after first observing performance of Group A and participating in the debriefing. We developed a D-CPR checklist to assess team performance. Results Overall there were large variations in how accurately the nursing student teams performed the specific parts of the D-CPR algorithm. While few teams performed opening the airways and examination of breathing correctly, all teams used a 30:2 compression: ventilation ratio. We found no difference between Group A and Group B in D-CPR performance, either in regard to total points on the check list or to time variables. Conclusion We found that none of the nursing student teams achieved top scores on the D-CPR-checklist. Observing the training of other teams did not increase subsequent performance. We think all this indicates that more time must be assigned for repetitive practice and reflection. Moreover, the most important aspects of D-CPR, such as early defibrillation and hands-off time in relation to shock, must be highlighted in team

  1. Polarized neutron spectrometer

    International Nuclear Information System (INIS)

    Abov, Yu.G.; Novitskij, V.V.; Alfimenkov, V.P.; Galinskij, E.M.; Mareev, Yu.D.; Pikel'ner, L.B.; Chernikov, A.N.; Lason', L.; Tsulaya, V.M.; Tsulaya, M.I.

    2000-01-01

    The polarized neutron spectrometer, intended for studying the interaction of polarized neutrons with nuclei and condensed media in the area of energies from thermal up to several electron-volt, is developed at the IBR-2 reactor (JINR, Dubna). Diffraction on the Co(92%)-Fe(8%) magnetized monocrystals is used for the neutron polarization and polarization analysis. The neutron polarization within the whole energy range equals ∼ 95% [ru

  2. Polarization sensitive camera for the in vitro diagnostic and monitoring of dental erosion

    Science.gov (United States)

    Bossen, Anke; Rakhmatullina, Ekaterina; Lussi, Adrian; Meier, Christoph

    Due to a frequent consumption of acidic food and beverages, the prevalence of dental erosion increases worldwide. In an initial erosion stage, the hard dental tissue is softened due to acidic demineralization. As erosion progresses, a gradual tissue wear occurs resulting in thinning of the enamel. Complete loss of the enamel tissue can be observed in severe clinical cases. Therefore, it is essential to provide a diagnosis tool for an accurate detection and monitoring of dental erosion already at early stages. In this manuscript, we present the development of a polarization sensitive imaging camera for the visualization and quantification of dental erosion. The system consists of two CMOS cameras mounted on two sides of a polarizing beamsplitter. A horizontal linearly polarized light source is positioned orthogonal to the camera to ensure an incidence illumination and detection angles of 45°. The specular reflected light from the enamel surface is collected with an objective lens mounted on the beam splitter and divided into horizontal (H) and vertical (V) components on each associate camera. Images of non-eroded and eroded enamel surfaces at different erosion degrees were recorded and assessed with diagnostic software. The software was designed to generate and display two types of images: distribution of the reflection intensity (V) and a polarization ratio (H-V)/(H+V) throughout the analyzed tissue area. The measurements and visualization of these two optical parameters, i.e. specular reflection intensity and the polarization ratio, allowed detection and quantification of enamel erosion at early stages in vitro.

  3. Ultra-wideband circular-polarization converter with micro-split Jerusalem-cross metasurfaces

    Science.gov (United States)

    Gao, Xi; Yu, Xing-Yang; Cao, Wei-Ping; Jiang, Yan-Nan; Yu, Xin-Hua

    2016-12-01

    An ultrathin micro-split Jerusalem-cross metasurface is proposed in this paper, which can efficiently convert the linear polarization of electromagnetic (EM) wave into the circular polarization in ultra-wideband. By symmetrically employing two micro-splits on the horizontal arm (in the x direction) of the Jerusalem-cross structure, the bandwidth of the proposed device is significantly extended. Both simulated and experimental results show that the proposed metasurface is able to convert linearly polarized waves into circularly polarized waves in a frequency range from 12.4 GHz to 21 GHz, with an axis ratio better than 1 dB. The simulated results also show that such a broadband and high-performance are maintained over a wide range of incident angle. The presented polarization converter can be used in a number of areas, such as spectroscopy and wireless communications. Project supported by the National Natural Science Foundation of China (Grant Nos. 61461016 and 61661012), the Natural Science Foundation of Guangxi Zhuang Autonomous Region, China (Grant Nos. 2014GXNSFAA118366, 2014GXNSFAA118283, and 2015jjBB7002), and the Innovation Project of Graduate Education of Guilin University of Electronic Technology, China (Grant No. 2016YJCX82).

  4. Testing the existence of optical linear polarization in young brown dwarfs

    Science.gov (United States)

    Manjavacas, E.; Miles-Páez, P. A.; Zapatero-Osorio, M. R.; Goldman, B.; Buenzli, E.; Henning, T.; Pallé, E.; Fang, M.

    2017-07-01

    Linear polarization can be used as a probe of the existence of atmospheric condensates in ultracool dwarfs. Models predict that the observed linear polarization increases with the degree of oblateness, which is inversely proportional to the surface gravity. We aimed to test the existence of optical linear polarization in a sample of bright young brown dwarfs, with spectral types between M6 and L2, observable from the Calar Alto Observatory, and cataloged previously as low gravity objects using spectroscopy. Linear polarimetric images were collected in I and R band using CAFOS at the 2.2-m telescope in Calar Alto Observatory (Spain). The flux ratio method was employed to determine the linear polarization degrees. With a confidence of 3σ, our data indicate that all targets have a linear polarimetry degree in average below 0.69 per cent in the I band, and below 1.0 per cent in the R band, at the time they were observed. We detected significant (I.e. P/σ ≥ 3) linear polarization for the young M6 dwarf 2MASS J04221413+1530525 in the R band, with a degree of p* = 0.81 ± 0.17 per cent.

  5. PolarTrack: Optical Outside-In Device Tracking that Exploits Display Polarization

    DEFF Research Database (Denmark)

    Rädle, Roman; Jetter, Hans-Christian; Fischer, Jonathan

    2018-01-01

    PolarTrack is a novel camera-based approach to detecting and tracking mobile devices inside the capture volume. In PolarTrack, a polarization filter continuously rotates in front of an off-the-shelf color camera, which causes the displays of observed devices to periodically blink in the camera feed....... The periodic blinking results from the physical characteristics of current displays, which shine polarized light either through an LC overlay to produce images or through a polarizer to reduce light reflections on OLED displays. PolarTrack runs a simple detection algorithm on the camera feed to segment...... displays and track their locations and orientations, which makes PolarTrack particularly suitable as a tracking system for cross-device interaction with mobile devices. Our evaluation of PolarTrack's tracking quality and comparison with state-of-the-art camera-based multi-device tracking showed a better...

  6. Lunar true polar wander inferred from polar hydrogen.

    Science.gov (United States)

    Siegler, M A; Miller, R S; Keane, J T; Laneuville, M; Paige, D A; Matsuyama, I; Lawrence, D J; Crotts, A; Poston, M J

    2016-03-24

    The earliest dynamic and thermal history of the Moon is not well understood. The hydrogen content of deposits near the lunar poles may yield insight into this history, because these deposits (which are probably composed of water ice) survive only if they remain in permanent shadow. If the orientation of the Moon has changed, then the locations of the shadowed regions will also have changed. The polar hydrogen deposits have been mapped by orbiting neutron spectrometers, and their observed spatial distribution does not match the expected distribution of water ice inferred from present-day lunar temperatures. This finding is in contrast to the distribution of volatiles observed in similar thermal environments at Mercury's poles. Here we show that polar hydrogen preserves evidence that the spin axis of the Moon has shifted: the hydrogen deposits are antipodal and displaced equally from each pole along opposite longitudes. From the direction and magnitude of the inferred reorientation, and from analysis of the moments of inertia of the Moon, we hypothesize that this change in the spin axis, known as true polar wander, was caused by a low-density thermal anomaly beneath the Procellarum region. Radiogenic heating within this region resulted in the bulk of lunar mare volcanism and altered the density structure of the Moon, changing its moments of inertia. This resulted in true polar wander consistent with the observed remnant polar hydrogen. This thermal anomaly still exists and, in part, controls the current orientation of the Moon. The Procellarum region was most geologically active early in lunar history, which implies that polar wander initiated billions of years ago and that a large portion of the measured polar hydrogen is ancient, recording early delivery of water to the inner Solar System. Our hypothesis provides an explanation for the antipodal distribution of lunar polar hydrogen, and connects polar volatiles to the geologic and geophysical evolution of the Moon

  7. Polarized proton beams

    International Nuclear Information System (INIS)

    Roser, T.

    1995-01-01

    The acceleration of polarized proton beams in circular accelerators is complicated by the presence of numerous depolarizing spin resonances. Careful and tedious minimization of polarization loss at each of these resonances allowed acceleration of polarized proton beams up to 22 GeV. It has been the hope that Siberian Snakes, which are local spin rotators inserted into ring accelerators, would eliminate these resonances and allow acceleration of polarized beams with the same ease and efficiency that is now routine for unpolarized beams. First tests at IUCF with a full Siberian Snake showed that the spin dynamics with a Snake can be understood in detail. The author now has results of the first tests of a partial Siberian Snake at the AGS, accelerating polarized protons to an energy of about 25 GeV. These successful tests of storage and acceleration of polarized proton beams open up new possibilities such as stored polarized beams for internal target experiments and high energy polarized proton colliders

  8. ERC 2010 guidelines for adult and pediatric resuscitation: summary of major changes.

    Science.gov (United States)

    Sandroni, C; Nolan, J

    2011-02-01

    The new European Resuscitation Council (ERC) guidelines for cardiopulmonary resuscitation (CPR) published on October 18th, 2010, replace those published in 2005 and are based on the latest International Consensus on CPR Science with Treatment Recommendations (CoSTR). For both adult and pediatric resuscitation, the most important general changes include: the introduction of chest compression-only CPR in primary cardiac arrest as an option for rescuers who are unable or unwilling to perform expired-air ventilation; increased emphasis on uninterrupted, good-quality CPR and minimisation of both pre- and post-shock pauses during defibrillation. For adult resuscitation, the recommended chest compression depth and rate are 5-6 cm and 100-120 compressions per minute, respectively. Both a specific period of CPR before defibrillation during out-of-hospital resuscitation and use of endotracheal route for drug delivery during advanced life support are no longer recommended. During postresuscitation care, inspired oxygen should be titrated to obtain an arterial oxygen saturation of 94-98%, to avoid possible damage from hyperoxemia. In pediatric resuscitation, the role of pulse palpation for the diagnosis of cardiac arrest has been de-emphasised. The compression-to-ventilation ratio depends on the number of rescuers available, and a 30:2 ratio is acceptable even for rescuers with a duty to respond if they are alone. Chest compression depth should be at least 1/3 of the anterior-posterior chest diameter. The use of automated external defibrillators for children under one year of age should be considered.

  9. Ultracompact 1×4 TM-polarized beam splitter based on photonic crystal surface mode.

    Science.gov (United States)

    Jiang, Bin; Zhang, Yejin; Wang, Yufei; Liu, Anjin; Zheng, Wanhua

    2012-05-01

    We provide an improved surface-mode photonic crystal (PhC) T-junction waveguide, combine it with an improved PhC bandgap T-junction waveguide, and then provide an ultracompact 1×4 TM-polarized beam splitter. The energy is split equally into the four output waveguides. The maximal transmission ratio of each output waveguide branch equals 24.7%, and the corresponding total transmission ratio of the ultracompact 1×4 beam splitter equals 98.8%. The normalized frequency of maximal transmission ratio is 0.397(2πc/a), and the bandwidth of the ultracompact 1×4 TM-polarized beam splitter is 0.0106(2πc/a). To the best of our knowledge, this is the first time such a high-efficiency 1×4 beam splitter exploiting the nonradiative surface mode as a guided mode has been proposed. Although we only employed a 1×4 beam splitter, our design can easily be extended to other 1×n beam splitters.

  10. A semiconductor metasurface with multiple functionalities: A polarizing beam splitter with simultaneous focusing ability

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Hyung; Jin Jung, Myoung; Ho Song, Seok, E-mail: shsong@hanyang.ac.kr [Department of Physics, Hanyang University, Seoul (Korea, Republic of); Woong Yoon, Jae; Magnusson, Robert [Department of Electrical Engineering, University of Texas–Arlington, Arlington, Texas 76019 (United States); Kyun Hong, Jong [Department of Electrical Engineering, Hanyang University, Seoul (Korea, Republic of)

    2014-06-09

    We propose a semiconductor metasurface that simultaneously performs two independent functions: focusing and polarization filtering. The wavefronts of the reflected and transmitted light distributions are precisely manipulated by spatial parametric variation of a subwavelength thin-film Si grating, which inherently possesses polarization filtering properties. We design a 12-μm-wide metasurface containing only nineteen Si grating ridges. Under a 10-μm-wide unpolarized Gaussian beam incidence at wavelength of 1.55 μm, the resulting device shows promising theoretical performance with high power efficiency exceeding 80% and polarization extinction ratio of ∼10 dB with focal spot diameters near 1–2 μm.

  11. Nanopatterned bulk metallic glass-based biomaterials modulate macrophage polarization.

    Science.gov (United States)

    Shayan, Mahdis; Padmanabhan, Jagannath; Morris, Aaron H; Cheung, Bettina; Smith, Ryan; Schroers, Jan; Kyriakides, Themis R

    2018-06-01

    Polarization of macrophages by chemical, topographical and mechanical cues presents a robust strategy for designing immunomodulatory biomaterials. Here, we studied the ability of nanopatterned bulk metallic glasses (BMGs), a new class of metallic biomaterials, to modulate murine macrophage polarization. Cytokine/chemokine analysis of IL-4 or IFNγ/LPS-stimulated macrophages showed that the secretion of TNF-α, IL-1α, IL-12, CCL-2 and CXCL1 was significantly reduced after 24-hour culture on BMGs with 55 nm nanorod arrays (BMG-55). Additionally, under these conditions, macrophages increased phagocytic potential and exhibited decreased cell area with multiple actin protrusions. These in vitro findings suggest that nanopatterning can modulate biochemical cues such as IFNγ/LPS. In vivo evaluation of the subcutaneous host response at 2 weeks demonstrated that the ratio of Arg-1 to iNOS increased in macrophages adjacent to BMG-55 implants, suggesting modulation of polarization. In addition, macrophage fusion and fibrous capsule thickness decreased and the number and size of blood vessels increased, which is consistent with changes in macrophage responses. Our study demonstrates that nanopatterning of BMG implants is a promising technique to selectively polarize macrophages to modulate the immune response, and also presents an effective tool to study mechanisms of macrophage polarization and function. Implanted biomaterials elicit a complex series of tissue and cellular responses, termed the foreign body response (FBR), that can be influenced by the polarization state of macrophages. Surface topography can influence polarization, which is broadly characterized as either inflammatory or repair-like. The latter has been linked to improved outcomes of the FBR. However, the impact of topography on macrophage polarization is not fully understood, in part, due to a lack of high moduli biomaterials that can be reproducibly processed at the nanoscale. Here, we studied

  12. Charge transport in non-polar and semi-polar III-V nitride heterostructures

    International Nuclear Information System (INIS)

    Konar, Aniruddha; Verma, Amit; Fang, Tian; Zhao, Pei; Jana, Raj; Jena, Debdeep

    2012-01-01

    Compared to the intense research focus on the optical properties, the transport properties in non-polar and semi-polar III-nitride semiconductors remain relatively unexplored to date. The purpose of this paper is to discuss charge-transport properties in non-polar and semi-polar orientations of GaN in a comparative fashion to what is known for transport in polar orientations. A comprehensive approach is adopted, starting from an investigation of the differences in the electronic bandstructure along different polar orientations of GaN. The polarization fields along various orientations are then discussed, followed by the low-field electron and hole mobilities. A number of scattering mechanisms that are specific to non-polar and semi-polar GaN heterostructures are identified, and their effects are evaluated. Many of these scattering mechanisms originate due to the coupling of polarization with disorder and defects in various incarnations depending on the crystal orientation. The effect of polarization orientation on carrier injection into quantum-well light-emitting diodes is discussed. This paper ends with a discussion of orientation-dependent high-field charge-transport properties including velocity saturation, instabilities and tunneling transport. Possible open problems and opportunities are also discussed. (paper)

  13. Production of polarized vector mesons off nuclei

    International Nuclear Information System (INIS)

    Kopeliovich, B. Z.; Nemchik, J.; Schmidt, Ivan

    2007-01-01

    Using the light-cone QCD dipole formalism we investigate manifestations of color transparency (CT) and coherence length (CL) effects in electroproduction of longitudinally (L) and transversally (T) polarized vector mesons. Motivated by forthcoming data from the HERMES experiment we predict both the A and Q 2 dependence of the L/T ratios for ρ 0 mesons produced coherently and incoherently off nuclei. For an incoherent reaction the CT and CL effects add up and result in a monotonic A dependence of the L/T ratio at different values of Q 2 . In contrast, for a coherent process the contraction of the CL with Q 2 causes an effect opposite to that of CT and we expect quite a nontrivial A dependence

  14. Approximate likelihood approaches for detecting the influence of primordial gravitational waves in cosmic microwave background polarization

    Science.gov (United States)

    Pan, Zhen; Anderes, Ethan; Knox, Lloyd

    2018-05-01

    One of the major targets for next-generation cosmic microwave background (CMB) experiments is the detection of the primordial B-mode signal. Planning is under way for Stage-IV experiments that are projected to have instrumental noise small enough to make lensing and foregrounds the dominant source of uncertainty for estimating the tensor-to-scalar ratio r from polarization maps. This makes delensing a crucial part of future CMB polarization science. In this paper we present a likelihood method for estimating the tensor-to-scalar ratio r from CMB polarization observations, which combines the benefits of a full-scale likelihood approach with the tractability of the quadratic delensing technique. This method is a pixel space, all order likelihood analysis of the quadratic delensed B modes, and it essentially builds upon the quadratic delenser by taking into account all order lensing and pixel space anomalies. Its tractability relies on a crucial factorization of the pixel space covariance matrix of the polarization observations which allows one to compute the full Gaussian approximate likelihood profile, as a function of r , at the same computational cost of a single likelihood evaluation.

  15. Polarization-sensitive color in butterfly scales: polarization conversion from ridges with reflecting elements.

    Science.gov (United States)

    Zhang, Ke; Tang, Yiwen; Meng, Jinsong; Wang, Ge; Zhou, Han; Fan, Tongxiang; Zhang, Di

    2014-11-03

    Polarization-sensitive color originates from polarization-dependent reflection or transmission, exhibiting abundant light information, including intensity, spectral distribution, and polarization. A wide range of butterflies are physiologically sensitive to polarized light, but the origins of polarized signal have not been fully understood. Here we systematically investigate the colorful scales of six species of butterfly to reveal the physical origins of polarization-sensitive color. Microscopic optical images under crossed polarizers exhibit their polarization-sensitive characteristic, and micro-structural characterizations clarify their structural commonality. In the case of the structural scales that have deep ridges, the polarization-sensitive color related with scale azimuth is remarkable. Periodic ridges lead to the anisotropic effective refractive indices in the parallel and perpendicular grating orientations, which achieves form-birefringence, resulting in the phase difference of two different component polarized lights. Simulated results show that ridge structures with reflecting elements reflect and rotate the incident p-polarized light into s-polarized light. The dimensional parameters and shapes of grating greatly affect the polarization conversion process, and the triangular deep grating extends the outstanding polarization conversion effect from the sub-wavelength period to the period comparable to visible light wavelength. The parameters of ridge structures in butterfly scales have been optimized to fulfill the polarization-dependent reflection for secret communication. The structural and physical origin of polarization conversion provides a more comprehensive perspective on the creation of polarization-sensitive color in butterfly wing scales. These findings show great potential in anti-counterfeiting technology and advanced optical material design.

  16. Polarizing beam splitter of deep-etched triangular-groove fused-silica gratings.

    Science.gov (United States)

    Zheng, Jiangjun; Zhou, Changhe; Feng, Jijun; Wang, Bo

    2008-07-15

    We investigated the use of a deep-etched fused-silica grating with triangular-shaped grooves as a highly efficient polarizing beam splitter (PBS). A triangular-groove PBS grating is designed at a wavelength of 1550 nm to be used in optical communication. When it is illuminated in Littrow mounting, the transmitted TE- and TM-polarized waves are mainly diffracted in the minus-first and zeroth orders, respectively. The design condition is based on the average differences of the grating mode indices, which is verified by using rigorous coupled-wave analysis. The designed PBS grating is highly efficient over the C+L band range for both TE and TM polarizations (>97.68%). It is shown that such a triangular-groove PBS grating can exhibit a higher diffraction efficiency, a larger extinction ratio, and less reflection loss than the binary-phase fused-silica PBS grating.

  17. Sources of polarized neutrons

    International Nuclear Information System (INIS)

    Walter, L.

    1983-01-01

    Various sources of polarized neutrons are reviewed. Monoenergetic source produced with unpolarized or polarized beams, white sources of polarized neutrons, production by transmissions through polarized hydrogen targets and polarized thermal neutronsare discussed, with appropriate applications included. (U.K.)

  18. Circularly polarized light to study linear magneto-optics for ferrofluids: θ-scan technique

    Science.gov (United States)

    Meng, Xiangshen; Huang, Yan; He, Zhenghong; Lin, Yueqiang; Liu, Xiaodong; Li, Decai; Li, Jian; Qiu, Xiaoyan

    2018-06-01

    Circularly polarized light can be divided into two vertically linearly polarized light beams with  ±π/2 phase differences. In the presence of an external magnetic field, when circularly polarized light travels through a ferrofluid film, whose thickness is no more than that of λ/4 plate, magneto-optical, magnetic birefringence and dichroism effects cause the transmitted light to behave as elliptically polarized light. Using angular scan by a continuously rotating polarizer as analyzer, the angular (θ) distribution curve of relative intensity (T) corresponding to elliptically polarized light can be measured. From the T  ‑  θ curve having ellipsometry, the parameters such as the ratio of short to long axis, and angular orientation of the long axis to the vertical field direction can be obtained. Thus, magnetic birefringence and dichroism can be probed simultaneously by measuring magneto-optical, positive or negative birefringence and dichroism features from the transmission mode. The proposed method is called θ-scan technique, and can accurately determine sample stability, magnetic field direction, and cancel intrinsic light source ellipticity. This study may be helpful to further research done to ferrofluids and other similar colloidal samples with anisotropic optics.

  19. PolarHub: A Global Hub for Polar Data Discovery

    Science.gov (United States)

    Li, W.

    2014-12-01

    This paper reports the outcome of a NSF project in developing a large-scale web crawler PolarHub to discover automatically the distributed polar dataset in the format of OGC web services (OWS) in the cyberspace. PolarHub is a machine robot; its goal is to visit as many webpages as possible to find those containing information about polar OWS, extract this information and store it into the backend data repository. This is a very challenging task given huge data volume of webpages on the Web. Three unique features was introduced in PolarHub to make it distinctive from earlier crawler solutions: (1) a multi-task, multi-user, multi-thread support to the crawling tasks; (2) an extensive use of thread pool and Data Access Object (DAO) design patterns to separate persistent data storage and business logic to achieve high extendibility of the crawler tool; (3) a pattern-matching based customizable crawling algorithm to support discovery of multi-type geospatial web services; and (4) a universal and portable client-server communication mechanism combining a server-push and client pull strategies for enhanced asynchronous processing. A series of experiments were conducted to identify the impact of crawling parameters to the overall system performance. The geographical distribution pattern of all PolarHub identified services is also demonstrated. We expect this work to make a major contribution to the field of geospatial information retrieval and geospatial interoperability, to bridge the gap between data provider and data consumer, and to accelerate polar science by enhancing the accessibility and reusability of adequate polar data.

  20. NEAR-INFRARED POLARIZATION SOURCE CATALOG OF THE NORTHEASTERN REGIONS OF THE LARGE MAGELLANIC CLOUD

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jaeyeong; Pak, Soojong [School of Space Research, Kyung Hee University, 1 Seocheon-dong, Giheung-gu, Yongin, Gyeonggi-do 446-701 (Korea, Republic of); Jeong, Woong-Seob; Park, Won-Kee [Korea Astronomy and Space Science Institute, 776 Daedeok-daero, Yuseong-gu, Daejeon 305-348 (Korea, Republic of); Tamura, Motohide, E-mail: jaeyeong@khu.ac.kr, E-mail: jeongws@kasi.re.kr [The University of Tokyo/National Astronomical Observatory of Japan/Astrobiology Center, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan)

    2016-01-15

    We present a near-infrared band-merged photometric and polarimetric catalog for the 39′ × 69′ fields in the northeastern part of the Large Magellanic Cloud (LMC), which were observed using SIRPOL, an imaging polarimeter of the InfraRed Survey Facility. This catalog lists 1858 sources brighter than 14 mag in the H band with a polarization signal-to-noise ratio greater than three in the J, H, or K{sub s} bands. Based on the relationship between the extinction and the polarization degree, we argue that the polarization mostly arises from dichroic extinctions caused by local interstellar dust in the LMC. This catalog allows us to map polarization structures to examine the global geometry of the local magnetic field, and to show a statistical analysis of the polarization of each field to understand its polarization properties. In the selected fields with coherent polarization position angles, we estimate magnetic field strengths in the range of 3−25 μG using the Chandrasekhar–Fermi method. This implies the presence of large-scale magnetic fields on a scale of around 100 parsecs. When comparing mid- and far-infrared dust emission maps, we confirmed that the polarization patterns are well aligned with molecular clouds around the star-forming regions.