  1. Establishing an external quality assessment scheme for point-of-care international normalized ratio in Thailand.

    Science.gov (United States)

    Tientadakul, P; Chuntarut, A

    2015-08-01

    Effective warfarin therapy management has gained national interest, resulting in the increased use of point-of-care testing (POCT) for international normalized ratio (INR). External quality assessment (EQA) is recommended to ensure quality of the testing. CoaguChek XS and CoaguChek XS Plus are the only commonly available POCT INR monitors in Thailand. Therefore, Thailand NEQAS for Blood Coagulation initiated the scheme for POCT INR in 2013, including only hospitals using these devices. Questionnaires were sent to the hospitals, enquiring about their interest in EQA participation. Two surveys were distributed; each included five certified European Concerted Action on Anticoagulation (ECAA) INR plasma sets. Unsatisfactory performance was indicated by a 15% deviation from the certified mean INR value. There were 156 hospitals using the devices. Thirty-five hospitals responded to the questionnaires. Medical personnel undertaking POCT INR were limited to laboratory staff in 29 (83%) of these centers, and 31 hospitals actually participated. The medians of results from participants were the same or nearly the same as the certified mean INRs. External quality assessment for POCT INR in Thailand is feasible using the ECAA plasmas as control materials. The results therefore appear encouraging to other developing countries to establish their own EQA schemes. © 2014 John Wiley & Sons Ltd.

  2. Internal medicine point-of-care ultrasound assessment of left ventricular function correlates with formal echocardiography.

    Science.gov (United States)

    Johnson, Benjamin K; Tierney, David M; Rosborough, Terry K; Harris, Kevin M; Newell, Marc C

    2016-02-01

    Although focused cardiac ultrasonographic (FoCUS) examination has been evaluated in emergency departments and intensive care units with good correlation to formal echocardiography, accuracy for the assessment of left ventricular systolic function (LVSF) when performed by internal medicine physicians still needs independent evaluation. This prospective observational study in a 640-bed, academic, quaternary care center, included 178 inpatients examined by 10 internal medicine physicians who had completed our internal medicine bedside ultrasound training program. The ability to estimate LVSF with FoCUS as "normal," "mild to moderately decreased," or "severely decreased" was compared with left ventricular ejection fraction (>50%, 31-49%, and internal medicine physician-performed FoCUS and formal echocardiography for any LVSF impairment was "good/substantial" with κ = 0.77 (p Internal medicine physicians using FoCUS identify normal versus decreased LVSF with high sensitivity, specificity, and "good/substantial" interrater agreement when compared with formal echocardiography. These results support the role of cardiac FoCUS by properly trained internal medicine physicians for discriminating normal from reduced LVSF. © 2015 Wiley Periodicals, Inc.

  3. Point-of-care ultrasonography as a training milestone for internal medicine residents: the time is now.

    Science.gov (United States)

    Sabath, Bruce F; Singh, Gurkeerat

    2016-01-01

    Point-of-care (POC) ultrasonography is considered fundamental in emergency medicine training and recently has become a milestone in critical care fellowship programs as well. Currently, there is no such standard requirement for internal medicine residency programs in the United States. We present a new case and briefly review another case at our institution - a community hospital - in which internal medicine house staff trained in ultrasonography were able to uncover unexpected and critical diagnoses that significantly changed patient care and outcomes. We also review the growing evidence of the application of ultrasound in the diagnosis of a myriad of conditions encountered in general internal medicine as well as the mounting data on the ability of internal medicine residents to apply this technology accurately at the bedside. We advocate that the literature has sufficiently established the role of POC ultrasonography in general internal medicine that there should no longer be any delay in giving this an official place in the development of internal medicine trainees. This may be particularly useful in the community hospital setting where 24-h echocardiography or other sonography may not be readily available.

  4. International definition of a point-of-care test in family practice: a modified e-Delphi procedure.

    Science.gov (United States)

    Schols, Angel M R; Dinant, Geert-Jan; Hopstaken, Rogier; Price, Christopher P; Kusters, Ron; Cals, Jochen W L

    2018-01-29

    The use of point-of-care tests (POCTs) in family practice is increasing, and the term POCT is often used in medical literature and clinical practice. Yet, no widely supported definition by several professional fields exists. To reach consensus on an international definition of a POCT in family practice. We performed a modified international e-Delphi procedure of four rounds among expert panel members from different professional backgrounds-family practitioners, laboratory specialists, policymakers, researchers and manufacturers. Of 27 panel members from seven different countries, 26 participated in all rounds. Most panel members were active in POCT research or policymaking and 70% worked in family medicine. After choosing important components, structuring of answers and feedback, the following definition was chosen as the best or second best definition by 81% of panel members: a point-of-care test in family practice is a test to support clinical decision making, which is performed by a qualified member of the practice staff nearby the patient and on any part of the patient's body or its derivatives, during or very close to the time of consultation, to help the patient and physician to decide upon the best suited approach, and of which the results should be known at the time of the clinical decision making. The definition emerging from this study can inform family practitioners, laboratory specialists, policymakers and manufacturers on the most widely supported and recognized definition and could act as a clear starting point for the organization and execution of professional point-of-care testing in family practice worldwide. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Good quality of oral anticoagulation treatment in general practice using international normalised ratio point of care testing

    DEFF Research Database (Denmark)

    Løkkegaard, Thomas; Pedersen, Tina Heidi; Lind, Bent

    2015-01-01

    INTRODUCTION: Oral anticoagulation treatment (OACT) with warfarin is common in general practice. Increasingly, international normalised ratio (INR) point of care testing (POCT) is being used to manage patients. The aim of this study was to describe and analyse the quality of OACT with warfarin...... practices using INR POCT in the management of patients in warfarin treatment provided good quality of care. Sampling interval and diagnostic coding were significantly correlated with treatment quality....

  6. Good quality of oral anticoagulation treatment in general practice using international normalised ratio point of care testing

    DEFF Research Database (Denmark)

    Løkkegaard, Thomas; Pedersen, Tina Heidi; Lind, Bent

    2015-01-01

    INTRODUCTION: Oral anticoagulation treatment (OACT)with warfarin is common in general practice. Increasingly,international normalised ratio (INR) point of care testing(POCT) is being used to manage patients. The aim of thisstudy was to describe and analyse the quality of OACT withwarfarin...... in the management of patients in warfarintreatment provided good quality of care. Sampling intervaland diagnostic coding were significantly correlated withtreatment quality. FUNDING: The study received financial support from theSarah Krabbe Foundation, the General Practitioners’ Educationand Development Foundation...

  7. Internal Medicine Point-of-Care Ultrasound Curriculum: Consensus Recommendations from the Canadian Internal Medicine Ultrasound (CIMUS) Group.

    Science.gov (United States)

    Ma, Irene W Y; Arishenkoff, Shane; Wiseman, Jeffrey; Desy, Janeve; Ailon, Jonathan; Martin, Leslie; Otremba, Mirek; Halman, Samantha; Willemot, Patrick; Blouw, Marcus

    2017-09-01

    Bedside point-of-care ultrasound (POCUS) is increasingly used to assess medical patients. At present, no consensus exists for what POCUS curriculum is appropriate for internal medicine residency training programs. This document details the consensus-based recommendations by the Canadian Internal Medicine Ultrasound (CIMUS) group, comprising 39 members, representing 14 institutions across Canada. Guiding principles for selecting curricular content were determined a priori. Consensus was defined as agreement by at least 80% of the members on POCUS applications deemed appropriate for teaching and assessment of trainees in the core (internal medicine postgraduate years [PGY] 1-3) and expanded (general internal medicine PGY 4-5) training programs. We recommend four POCUS applications for the core PGY 1-3 curriculum (inferior vena cava, lung B lines, pleural effusion, and abdominal free fluid) and three ultrasound-guided procedures (central venous catheterization, thoracentesis, and paracentesis). For the expanded PGY 4-5 curriculum, we recommend an additional seven applications (internal jugular vein, lung consolidation, pneumothorax, knee effusion, gross left ventricular systolic function, pericardial effusion, and right ventricular strain) and four ultrasound-guided procedures (knee arthrocentesis, arterial line insertion, arterial blood gas sampling, and peripheral venous catheterization). These recommendations will provide a framework for training programs at a national level.

  8. Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis

    Directory of Open Access Journals (Sweden)

    Hedvig Toth-Székély

    2012-02-01

    Full Text Available Neonatal sepsis is still a leading cause of death among newborns. Therefore a protein-microarray for point-of-care testing that simultaneously quantifies the sepsis associated serum proteins IL-6, IL-8, IL-10, TNF alpha, S-100, PCT, E-Selectin, CRP and Neopterin has been developed. The chip works with only a 4 µL patient serum sample and hence minimizes excessive blood withdrawal from newborns. The 4 µL patient samples are diluted with 36 µL assay buffer and distributed to four slides for repetitive measurements. Streptavidin coated magnetic particles that act as distinct stirring detection components are added, not only to stir the sample, but also to detect antibody antigen binding events. We demonstrate that the test is complete within 2.5 h using a single step assay. S-100 conjugated to BSA is spotted in increasing concentrations to create an internal calibration. The presented low volume protein-chip fulfills the requirements of point-of-care testing for accurate and repeatable (CV < 14% quantification of serum proteins for the diagnosis of neonatal sepsis.

  9. Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials.

    Science.gov (United States)

    Meija, Juris; Chartrand, Michelle M G

    2018-01-01

    Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.

  10. [International Standards of Tuberculosis Care (ISTC)--comments from the German point of view].

    Science.gov (United States)

    Castell, S; Bauer, T; Diel, R; Hedrich, A; Magdorf, K; Rüsch-Gerdes, S; Schaberg, T; Loddenkemper, R

    2012-04-01

    The "International Standards for Tuberculosis Care" (ISTC) were developed by the World Health Organisation (WHO) and others to provide internationally agreed and, if possible, evidence-based standards for tuberculosis care including the care by private providers who are not part of national tuberculosis programmes or health-care systems. Hence, the ISTC primarily address resource-restrained countries with high tuberculosis prevalence. In this article, the German translation of the 21 standards from 2009 is presented - addressing diagnostic and therapeutic standards, co-infection (especially with HIV) and public-health issues. The accompanying comments show how these standards have to be modified for Germany due to the medical resources available here and country-specific characteristics respectively. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Good quality of oral anticoagulation treatment in general practice using international normalised ratio point of care testing

    DEFF Research Database (Denmark)

    Løkkegaard, Thomas; Pedersen, Tina Heidi; Lind, Bent

    2015-01-01

    collected retrospectively for a period of six months. For each patient, time in therapeutic range (TTR) was calculated and correlated with practice and patient characteristics using multilevel linear regression models. RESULTS: We identified 447 patients in warfarin treatment in the 20 practices using POCT......INTRODUCTION: Oral anticoagulation treatment (OACT) with warfarin is common in general practice. Increasingly, international normalised ratio (INR) point of care testing (POCT) is being used to manage patients. The aim of this study was to describe and analyse the quality of OACT with warfarin...

  12. The effectiveness of computer reminders versus postal reminders for improving quality assessment for point-of-care testing in primary care

    DEFF Research Database (Denmark)

    Siersma, Volkert; Kousgaard, Marius Brostrøm; Reventlow, Susanne

    2015-01-01

    Rationale, aims and objectives: This study aimed to evaluate the relative effectiveness of electronic and postal reminders for increasing adherence to the quality assurance programme for the international normalized ratio (INR) point-of-care testing (POCT) device inprimary care. Methods: All 213...... family practices that use the Elective Laboratory of the Capital Region, Denmark, and regularly conduct INR POCT were randomly allocated into two similarly sized groups. During the 4-month intervention, these practices were sent either computer reminders (ComRem) or computer generated postal reminders...... (Postal) if they did not perform a split test to check the quality of their INR POCT for each calendar month. The adherence of the practices was tracked during the subsequent 8 months subdivided into two 4-month periods both without intervention. Outcomes were measures of split test procedure adherence...

  13. Comparison in stress of caring mothers of children with developmental, external and internal disorders and normal children

    Directory of Open Access Journals (Sweden)

    Narges Zamani

    2017-06-01

    Full Text Available However, having a baby brings positive emotions such as happiness, sense of maturity and proud, parenting's issue could cause high level of stress and child's characteristics was a detrimental factor which can effect on parent's stress, so the aim of this research was comparison of stress of caring in mothers of children with developmental, external, and internal disorders and normal children. The study population included all mothers of children with developmental, emotional, and disruptive behavior disorders, and mothers with normal children in Hamadan (a city in Iran. 240 mothers (4 groups include 60 mothers were chosen based on simple random sampling. Family inventory of life events and changes Mc Cubbin, Patterson & Wilson was used for assessing participants. The results showed that maternal stress in mothers with children who have diagnosis of disruptive behavior disorders were significantly more than of mothers of children with developmental disorders, emotional and mothers of normal children. The present study showed that disruptive behavior disorders in children have a greater impact on their mothers. So, we suggest approved psychological interventions for helping mothers of children with psychological problems, particularly children with external disorders.

  14. The patients' perspective of international normalized ratio self-testing, remote communication of test results and confidence to move to self-management.

    Science.gov (United States)

    Grogan, Anne; Coughlan, Michael; Prizeman, Geraldine; O'Connell, Niamh; O'Mahony, Nora; Quinn, Katherine; McKee, Gabrielle

    2017-12-01

    To elicit the perceptions of patients, who self-tested their international normalized ratio and communicated their results via a text or phone messaging system, to determine their satisfaction with the education and support that they received and to establish their confidence to move to self-management. Self-testing of international normalized ratio has been shown to be reliable and is fast becoming common practice. As innovations are introduced to point of care testing, more research is needed to elicit patients' perceptions of the self-testing process. This three site study used a cross-sectional prospective descriptive survey. Three hundred and thirty patients who were prescribed warfarin and using international normalized ratio self-testing were invited to take part in the study. The anonymous survey examined patient profile, patients' usage, issues, perceptions, confidence and satisfaction with using the self-testing system and their preparedness for self-management of warfarin dosage. The response rate was 57% (n = 178). Patients' confidence in self-testing was high (90%). Patients expressed a high level of satisfaction with the support received, but expressed the need for more information on support groups, side effects of warfarin, dietary information and how to dispose of needles. When asked if they felt confident to adjust their own warfarin levels 73% agreed. Chi-squared tests for independence revealed that none of the patient profile factors examined influenced this confidence. The patients cited the greatest advantages of the service were reduced burden, more autonomy, convenience and ease of use. The main disadvantages cited were cost and communication issues. Patients were satisfied with self-testing. The majority felt they were ready to move to self-management. The introduction of innovations to remote point of care testing, such as warfarin self-testing, needs to have support at least equal to that provided in a hospital setting. © 2017 John

  15. Palliative Care Exposure in Internal Medicine Residency Education: A Survey of ACGME Internal Medicine Program Directors.

    Science.gov (United States)

    Edwards, Asher; Nam, Samuel

    2018-01-01

    As the baby boomer generation ages, the need for palliative care services will be paramount and yet training for palliative care physicians is currently inadequate to meet the current palliative care needs. Nonspecialty-trained physicians will need to supplement the gap between supply and demand. Yet, no uniform guidelines exist for the training of internal medicine residents in palliative care. To our knowledge, no systematic study has been performed to evaluate how internal medicine residencies currently integrate palliative care into their training. In this study, we surveyed 338 Accreditation Council for Graduate Medical Education-accredited internal medicine program directors. We queried how palliative care was integrated into their training programs. The vast majority of respondents felt that palliative care training was "very important" (87.5%) and 75.9% of respondents offered some kind of palliative care rotation, often with a multidisciplinary approach. Moving forward, we are hopeful that the data provided from our survey will act as a launching point for more formal investigations into palliative care education for internal medicine residents. Concurrently, policy makers should aid in palliative care instruction by formalizing required palliative care training for internal medicine residents.

  16. Bedside ultrasonography (US), Echoscopy and US point of care as a new kind of stethoscope for Internal Medicine Departments: the training program of the Italian Internal Medicine Society (SIMI).

    Science.gov (United States)

    Arienti, Vincenzo; Di Giulio, Rosella; Cogliati, Chiara; Accogli, Esterita; Aluigi, Leonardo; Corazza, Gino Roberto

    2014-10-01

    In recent years, thanks to the development of miniaturized ultrasound devices, comparable to personal computers, tablets and even to smart phones, we have seen an increasing use of bedside ultrasound in internal medicine departments as a novel kind of ultrasound stethoscope. The clinical ultrasound-assisted approach has proved to be particularly useful in assessing patients with nodules of the neck, dyspnoea, abdominal pain, and with limb edema. In several cases, it has allowed a simple, rapid and precise diagnosis. Since 2005, the Italian Society of Internal Medicine and its Ultrasound Study Group has been holding a Summer School and training courses in ultrasound for residents in internal medicine. A national network of schools in bedside ultrasound was then organized for internal medicine specialists who want to learn this technique. Because bedside ultrasound is a user-dependent diagnostic method, it is important to define the limits and advantages of different new ultrasound devices, to classify them (i.e. Echoscopy and Point of Care Ultrasound), to establish appropriate different levels of competence and to ensure their specific training. In this review, we describe the point of view of the Italian Internal Medicine Society on these topics.

  17. Role of the pharmacist in delivering point-of-care therapy for ...

    African Journals Online (AJOL)

    The wide variation in biological effect, narrow therapeutic range and pharmacokinetic and pharmacodynamic characteristics of warfarin require monitoring of the international normalised ratio (INR). Point-of-care results that are readily accessible for interpretation, allows the pharmacist to make dose adjustments ...

  18. Evaluation of a point-of-care blood analyzer and determination of reference ranges for blood parameters in rockfish.

    Science.gov (United States)

    Harrenstien, Lisa A; Tornquist, Susan J; Miller-Morgan, Timothy J; Fodness, Brian G; Clifford, Kevin E

    2005-01-15

    To compare values of blood parameters in rockfish obtained by use of a point-of-care portable blood analyzer with values determined by a veterinary diagnostic laboratory, calculate reference ranges for various blood parameters in black rockfish, and compare values of blood parameters in clinically normal fish with those of fish with clinical abnormalities. Prospective study. 41 captive adult black rockfish (Sebastes melanops) and 4 captive adult blue rockfish (Sebastes mystinus). Rockfish were anesthetized with tricaine methanesulfonate for collection of blood samples. Heparinized blood samples were immediately analyzed with a point-of-care analyzer. Blood sodium, potassium, chloride, urea nitrogen, and glucose concentrations; Hct; pH; partial pressure of carbon dioxide; total carbon dioxide concentration; bicarbonate concentration; base excess; and hemoglobin concentration were determined. A microhematocrit technique was used to determine PCV, and a refractometer was used to estimate total plasma protein concentration. Paired heparinized blood samples were transported to a veterinary diagnostic laboratory for analyses. Data obtained with the point-of-care analyzer were reproducible; however, values for most blood parameters were significantly different from those obtained by the veterinary diagnostic laboratory. Fish with poor body condition had several blood parameter values that were lower than corresponding values in clinically normal fish. Point-of-care blood analyses may prove useful in rockfish. Point-of-care data for a large number of clinically normal fish must be obtained for reference ranges to be calculated, and further assessments of clinically abnormal fish are necessary to determine the relevance of the data.

  19. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    Science.gov (United States)

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  20. Effect of home testing of international normalized ratio on clinical events.

    Science.gov (United States)

    Matchar, David B; Jacobson, Alan; Dolor, Rowena; Edson, Robert; Uyeda, Lauren; Phibbs, Ciaran S; Vertrees, Julia E; Shih, Mei-Chiung; Holodniy, Mark; Lavori, Philip

    2010-10-21

    Warfarin anticoagulation reduces thromboembolic complications in patients with atrial fibrillation or mechanical heart valves, but effective management is complex, and the international normalized ratio (INR) is often outside the target range. As compared with venous plasma testing, point-of-care INR measuring devices allow greater testing frequency and patient involvement and may improve clinical outcomes. We randomly assigned 2922 patients who were taking warfarin because of mechanical heart valves or atrial fibrillation and who were competent in the use of point-of-care INR devices to either weekly self-testing at home or monthly high-quality testing in a clinic. The primary end point was the time to a first major event (stroke, major bleeding episode, or death). The patients were followed for 2.0 to 4.75 years, for a total of 8730 patient-years of follow-up. The time to the first primary event was not significantly longer in the self-testing group than in the clinic-testing group (hazard ratio, 0.88; 95% confidence interval, 0.75 to 1.04; P=0.14). The two groups had similar rates of clinical outcomes except that the self-testing group reported more minor bleeding episodes. Over the entire follow-up period, the self-testing group had a small but significant improvement in the percentage of time during which the INR was within the target range (absolute difference between groups, 3.8 percentage points; P<0.001). At 2 years of follow-up, the self-testing group also had a small but significant improvement in patient satisfaction with anticoagulation therapy (P=0.002) and quality of life (P<0.001). As compared with monthly high-quality clinic testing, weekly self-testing did not delay the time to a first stroke, major bleeding episode, or death to the extent suggested by prior studies. These results do not support the superiority of self-testing over clinic testing in reducing the risk of stroke, major bleeding episode, and death among patients taking warfarin

  1. Point prevalence survey of antimicrobial utilization in a Canadian tertiary-care teaching hospital

    Directory of Open Access Journals (Sweden)

    Colin Lee

    2015-06-01

    Conclusion: This prospective point prevalence survey provided important baseline information on antimicrobial use within a large tertiary care teaching hospital and identified potential targets for future antimicrobial stewardship initiatives. A multi-center point prevalence survey should be considered to identify patterns of antimicrobial use in Canada and to establish the first steps toward international antimicrobial surveillance.

  2. Rapid point-of-care breath test for biomarkers of breast cancer and abnormal mammograms.

    Directory of Open Access Journals (Sweden)

    Michael Phillips

    Full Text Available BACKGROUND: Previous studies have reported volatile organic compounds (VOCs in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. METHODS: 244 women had a screening mammogram (93/37 normal/abnormal or a breast biopsy (cancer/no cancer 35/79. A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air. Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve. Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO procedure. RESULTS: Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO [C-statistic value], negative predictive value 99.9%; normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO; and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO. CONCLUSIONS: A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity.

  3. Point-of-care hemoglobin testing for postmortem diagnosis of anemia.

    Science.gov (United States)

    Na, Joo-Young; Park, Ji Hye; Choi, Byung Ha; Kim, Hyung-Seok; Park, Jong-Tae

    2018-03-01

    An autopsy involves examination of a body using invasive methods such as dissection, and includes various tests using samples procured during dissection. During medicolegal autopsies, the blood carboxyhemoglobin concentration is commonly measured using the AVOXimeter® 4000 as a point-of-care test. When evaluating the body following hypovolemic shock, characteristics such as reduced livor mortis or an anemic appearance of the viscera can be identified, but these observations arequite subjective. Thus, a more objective test is required for the postmortem diagnosis of anemia. In the present study, the AVOXimeter® 4000 was used to investigate the utility of point-of-care hemoglobin testing. Hemoglobin tests were performed in 93 autopsy cases. The AVOXimeter® 4000 and the BC-2800 Auto Hematology Analyzer were used to test identical samples in 29 of these cases. The results of hemoglobin tests performed with these two devices were statistically similar (r = 0.969). The results of hemoglobin tests using postmortem blood were compared with antemortem test results from medical records from 31 cases, and these results were similar. In 13 of 17 cases of death from internal hemorrhage, hemoglobin levels were lower in the cardiac blood than in blood from the affected body cavity, likely due to compensatory changes induced by antemortem hemorrhage. It is concluded that blood hemoglobin testing may be useful as a point-of-care test for diagnosing postmortem anemia.

  4. Impact of point-of-care ultrasound on quality of care in clinical practice

    Directory of Open Access Journals (Sweden)

    Adhikari S

    2014-09-01

    Full Text Available Srikar Adhikari,1 Richard Amini,1 Lori A Stolz,1 Michael Blaivas2 1Department of Emergency Medicine, University of Arizona Medical Center, Tucson, AZ, 2Department of Internal Medicine, University of South Carolina School of Medicine, Columbia, SC, USA Abstract: The use of point-of-care (POC ultrasonography has rapidly expanded in recent years, in both academic and community settings. It is one of the few diagnostic modalities that can be performed rapidly at the bedside by a physician and has significant impact on patient outcomes. It is portable, readily accessible, and cost-effective, and has no risk of ionizing radiation. There is an abundance of evidence that supports the use of POC ultrasound by physicians in different subspecialties. Multiple studies have documented the diagnostic accuracy of POC ultrasound and its ability to decrease the time to definitive treatment. As ultrasound technology has advanced, POC ultrasound applications have also evolved from being used solely in patients with blunt abdominal trauma to applications for nearly every clinical scenario imaginable. From performing procedures more safely to diagnosing pathology more quickly, POC ultrasound is radically changing clinical practice, patient outcomes, and the overall quality of patient care a clinician can provide. Recently, there has been a paradigm shift involving a symptom-based approach to POC ultrasound. This unique symptom-based ultrasound approach has led to improved quality of care in a variety of clinical settings. Keywords: point-of-care ultrasound, ultrasonography, bedside ultrasound, emergency physician, emergency department, quality, symptom-based

  5. Point of Care Ultrasound

    DEFF Research Database (Denmark)

    Dietrich, Christoph F; Goudie, Adrian; Chiorean, Liliana

    2017-01-01

    Over the last decade, the use of portable ultrasound scanners has enhanced the concept of point of care ultrasound (PoC-US), namely, "ultrasound performed at the bedside and interpreted directly by the treating clinician." PoC-US is not a replacement for comprehensive ultrasound, but rather allows...... and critical care medicine, cardiology, anesthesiology, rheumatology, obstetrics, neonatology, gynecology, gastroenterology and many other applications. In the future, PoC-US will be more diverse than ever and be included in medical student training....

  6. Iterative closest normal point for 3D face recognition.

    Science.gov (United States)

    Mohammadzade, Hoda; Hatzinakos, Dimitrios

    2013-02-01

    The common approach for 3D face recognition is to register a probe face to each of the gallery faces and then calculate the sum of the distances between their points. This approach is computationally expensive and sensitive to facial expression variation. In this paper, we introduce the iterative closest normal point method for finding the corresponding points between a generic reference face and every input face. The proposed correspondence finding method samples a set of points for each face, denoted as the closest normal points. These points are effectively aligned across all faces, enabling effective application of discriminant analysis methods for 3D face recognition. As a result, the expression variation problem is addressed by minimizing the within-class variability of the face samples while maximizing the between-class variability. As an important conclusion, we show that the surface normal vectors of the face at the sampled points contain more discriminatory information than the coordinates of the points. We have performed comprehensive experiments on the Face Recognition Grand Challenge database, which is presently the largest available 3D face database. We have achieved verification rates of 99.6 and 99.2 percent at a false acceptance rate of 0.1 percent for the all versus all and ROC III experiments, respectively, which, to the best of our knowledge, have seven and four times less error rates, respectively, compared to the best existing methods on this database.

  7. Point-of-care and point-of-procedure optical imaging technologies for primary care and global health.

    Science.gov (United States)

    Boppart, Stephen A; Richards-Kortum, Rebecca

    2014-09-10

    Leveraging advances in consumer electronics and wireless telecommunications, low-cost, portable optical imaging devices have the potential to improve screening and detection of disease at the point of care in primary health care settings in both low- and high-resource countries. Similarly, real-time optical imaging technologies can improve diagnosis and treatment at the point of procedure by circumventing the need for biopsy and analysis by expert pathologists, who are scarce in developing countries. Although many optical imaging technologies have been translated from bench to bedside, industry support is needed to commercialize and broadly disseminate these from the patient level to the population level to transform the standard of care. This review provides an overview of promising optical imaging technologies, the infrastructure needed to integrate them into widespread clinical use, and the challenges that must be addressed to harness the potential of these technologies to improve health care systems around the world. Copyright © 2014, American Association for the Advancement of Science.

  8. Normalization constraint for variational bounds on fluid permeability

    International Nuclear Information System (INIS)

    Berryman, J.G.; Milton, G.W.

    1985-01-01

    A careful reexamination of the formulation of Prager's original variational principle for viscous flow through porous media has uncovered a subtle error in the normalization constraint on the trial functions. Although a certain surface integral of the true pressure field over the internal surface area always vanishes for isotropic materials, the corresponding surface integral for a given trial pressure field does not necessarily vanish but has nevertheless been previously neglected in the normalization. When this error is corrected, the form of the variational estimate is actually simpler than before and furthermore the resulting bounds have been shown to improve when the constant trial functions are used in either the two-point or three-point bounds

  9. CD-Based Microfluidics for Primary Care in Extreme Point-of-Care Settings

    Directory of Open Access Journals (Sweden)

    Suzanne Smith

    2016-01-01

    Full Text Available We review the utility of centrifugal microfluidic technologies applied to point-of-care diagnosis in extremely under-resourced environments. The various challenges faced in these settings are showcased, using areas in India and Africa as examples. Measures for the ability of integrated devices to effectively address point-of-care challenges are highlighted, and centrifugal, often termed CD-based microfluidic technologies, technologies are presented as a promising platform to address these challenges. We describe the advantages of centrifugal liquid handling, as well as the ability of a standard CD player to perform a number of common laboratory tests, fulfilling the role of an integrated lab-on-a-CD. Innovative centrifugal approaches for point-of-care in extremely resource-poor settings are highlighted, including sensing and detection strategies, smart power sources and biomimetic inspiration for environmental control. The evolution of centrifugal microfluidics, along with examples of commercial and advanced prototype centrifugal microfluidic systems, is presented, illustrating the success of deployment at the point-of-care. A close fit of emerging centrifugal systems to address a critical panel of tests for under-resourced clinic settings, formulated by medical experts, is demonstrated. This emphasizes the potential of centrifugal microfluidic technologies to be applied effectively to extremely challenging point-of-care scenarios and in playing a role in improving primary care in resource-limited settings across the developing world.

  10. A PDA based Point of Care E-Health Solution for Ambulatory Care

    Directory of Open Access Journals (Sweden)

    Daniel Walsh

    2005-11-01

    Full Text Available The adoption of PDAs and mobile communication is expected to provide a solution to the use of computer technology by healthcare workers at the point-of-care. The Australian National Health Information Strategy, Health Online, is providing national leadership for approaches to address the quality and availability of information to assist in the planning and delivery of care. One area for potential growth is the availability and capture of information at the point of care by healthcare providers. A key factor in the lack of adoption of systems, is that traditionally health care information systems have been designed for desktop computing whereas many healthcare workers are highly mobile. This paper discusses phase one of a larger, four-phase project which aims to develop information access applications at point-of-care for Ambulatory Care Services. The initial phase of the research (phase one involves workflow analysis, requirements specification and the development and testing of a system prototype to assess the feasibility of achieving increased efficiencies in workflow at the Ambulatory Care Service.

  11. Point-of-care diagnostics for niche applications.

    Science.gov (United States)

    Cummins, Brian M; Ligler, Frances S; Walker, Glenn M

    2016-01-01

    Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Noninferiority of glucose-6-phosphate dehydrogenase deficiency diagnosis by a point-of-care rapid test vs the laboratory fluorescent spot test demonstrated by copper inhibition in normal human red blood cells.

    Science.gov (United States)

    Baird, J Kevin; Dewi, Mewahyu; Subekti, Decy; Elyazar, Iqbal; Satyagraha, Ari W

    2015-06-01

    Tens of millions of patients diagnosed with vivax malaria cannot safely receive primaquine therapy against repeated attacks caused by activation of dormant liver stages called hypnozoites. Most of these patients lack access to screening for glucose-6-phosphate dehydrogenase (G6PD) deficiency, a highly prevalent disorder causing serious acute hemolytic anemia with primaquine therapy. We optimized CuCl inhibition of G6PD in normal red blood cells (RBCs) to assess G6PD diagnostic technologies suited to point of care in the impoverished rural tropics. The most widely applied technology for G6PD screening-the fluorescent spot test (FST)-is impractical in that setting. We evaluated a new point-of-care G6PD screening kit (CareStart G6PD, CSG) against FST using graded CuCl treatments to simulate variable hemizygous states, and varying proportions of CuCl-treated RBC suspensions to simulate variable heterozygous states of G6PD deficiency. In experiments double-blinded to CuCl treatment, technicians reading FST and CSG test (n = 269) classified results as positive or negative for deficiency. At G6PD activity ≤40% of normal (n = 112), CSG test was not inferior to FST in detecting G6PD deficiency (P = 0.003), with 96% vs 90% (P = 0.19) sensitivity and 75% and 87% (P = 0.01) specificity, respectively. The CSG test costs less, requires no specialized equipment, laboratory skills, or cold chain for successful application, and performs as well as the FST standard of care for G6PD screening. Such a device may vastly expand access to primaquine therapy and aid in mitigating the very substantial burden of morbidity and mortality imposed by the hypnozoite reservoir of vivax malaria. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Understanding the implementation of complex interventions in health care: the normalization process model

    Directory of Open Access Journals (Sweden)

    Rogers Anne

    2007-09-01

    Full Text Available Abstract Background The Normalization Process Model is a theoretical model that assists in explaining the processes by which complex interventions become routinely embedded in health care practice. It offers a framework for process evaluation and also for comparative studies of complex interventions. It focuses on the factors that promote or inhibit the routine embedding of complex interventions in health care practice. Methods A formal theory structure is used to define the model, and its internal causal relations and mechanisms. The model is broken down to show that it is consistent and adequate in generating accurate description, systematic explanation, and the production of rational knowledge claims about the workability and integration of complex interventions. Results The model explains the normalization of complex interventions by reference to four factors demonstrated to promote or inhibit the operationalization and embedding of complex interventions (interactional workability, relational integration, skill-set workability, and contextual integration. Conclusion The model is consistent and adequate. Repeated calls for theoretically sound process evaluations in randomized controlled trials of complex interventions, and policy-makers who call for a proper understanding of implementation processes, emphasize the value of conceptual tools like the Normalization Process Model.

  14. Empirical Radiometric Normalization of Road Points from Terrestrial Mobile Lidar System

    Directory of Open Access Journals (Sweden)

    Tee-Ann Teo

    2015-05-01

    Full Text Available Lidar data provide both geometric and radiometric information. Radiometric information is influenced by sensor and target factors and should be calibrated to obtain consistent energy responses. The radiometric correction of airborne lidar system (ALS converts the amplitude into a backscatter cross-section with physical meaning value by applying a model-driven approach. The radiometric correction of terrestrial mobile lidar system (MLS is a challenging task because it does not completely follow the inverse square range function at near-range. This study proposed a radiometric normalization workflow for MLS using a data-driven approach. The scope of this study is to normalize amplitude of road points for road surface classification, assuming that road points from different scanners or strips should have similar responses in overlapped areas. The normalization parameters for range effect were obtained from crossroads. The experiment showed that the amplitude difference between scanners and strips decreased after radiometric normalization and improved the accuracy of road surface classification.

  15. Should we Google it? Resource use by internal medicine residents for point-of-care clinical decision making.

    Science.gov (United States)

    Duran-Nelson, Alisa; Gladding, Sophia; Beattie, Jim; Nixon, L James

    2013-06-01

    To determine which resources residents use at the point-of-care (POC) for decision making, the drivers for selection of these resources, and how residents use Google/Google Scholar to answer clinical questions at the POC. In January 2012, 299 residents from three internal medicine residencies were sent an electronic survey regarding resources used for POC decision making. Resource use frequency and factors influencing choice were determined using descriptive statistics. Binary logistic regression analysis was performed to determine relationships between the independent variables. A total of 167 residents (56%) responded; similar numbers responded at each level of training. Residents most frequently reported using UpToDate and Google at the POC at least daily (85% and 63%, respectively), with speed and trust in the quality of information being the primary drivers of selection. Google, used by 68% of residents, was used primarily to locate Web sites and general information about diseases, whereas Google Scholar, used by 30% of residents, tended to be used for treatment and management decisions or locating a journal article. The findings suggest that internal medicine residents use UpToDate most frequently, followed by consultation with faculty and the search engines Google and Google Scholar; speed, trust, and portability are the biggest drivers for resource selection; and time and information overload appear to be the biggest barriers to resources such as Ovid MEDLINE. Residents frequently used Google and may benefit from further training in information management skills.

  16. Point-of-care estimation of haemoglobin concentration in neonates ...

    African Journals Online (AJOL)

    Objective. The HemoCue is a point-of-care analytical system for haemoglobin concentration (Hb) measurement. Point-of-care testing has been validated in hospitals and outpatient departments to assist with urgent patient management by providing rapid laboratory test results. Method. In this prospective study we compared ...

  17. RNI Point-of-care test (POCT: esperança ou ilusão? Point-of-care test (POCT INR: hope or illusion?

    Directory of Open Access Journals (Sweden)

    Luci Maria Sant'Ana Dusse

    2012-06-01

    Full Text Available Na última década, foram desenvolvidos os testes point-of-care visando à geração rápida de resultados de exames. Na área da hemostasia, a razão normatizada internacional, o RNI point-of-care test (RNI-POCT, constitui o principal exame dessa nova proposta. Esse teste tem grande potencial de benefício em situações em que o resultado rápido da RNI influencia a tomada de decisão clínica, como no acidente vascular cerebral isquêmico agudo, antes de procedimentos cirúrgicos e durante cirurgias cardíacas, além de permitir que o próprio paciente faça a monitoração da anticoagulação oral. Entretanto, a precisão e a acurácia da RNI-POCT ainda precisam ser aprimoradas para aumentar a eficácia e a eficiência do teste. A RDC/ANVISA Nº 302 deixa claro que os testes POCT devem ser supervisionados pelo responsável técnico do Laboratório Clínico nas fases pré-analítica, analítica e pós-analítica. Na prática, o laboratório não participa da execução desses testes e liberação dos resultados, não sendo, portanto, o mais indicado para garantir a qualidade dos mesmos. Os clínicos, especialmente aqueles envolvidos com a anticoagulação oral de pacientes, têm grande expectativa na incorporação da RNI-POCT na prática diária, apesar das limitações desse método. Esses profissionais mostram-se dispostos a treinar o paciente para realizar o teste, mas legalmente não são os responsáveis pela qualidade do mesmo e não estão preparados para a manutenção dos equipamentos. A definição do responsável pelo RNI-POCT precisa ser reavaliada pelos órgãos competentes, de forma a garantir que seja cumprida, e constitui etapa essencial para assegurar a qualidade do teste e, consequentemente, sua maior utilização.In the last decade, point-of-care tests were developed to provide rapid generation of test results. These tests have increasingly broad applications. In the area of hemostasis, the international normalized ratio

  18. An Investigation of the High Efficiency Estimation Approach of the Large-Scale Scattered Point Cloud Normal Vector

    Directory of Open Access Journals (Sweden)

    Xianglin Meng

    2018-03-01

    Full Text Available The normal vector estimation of the large-scale scattered point cloud (LSSPC plays an important role in point-based shape editing. However, the normal vector estimation for LSSPC cannot meet the great challenge of the sharp increase of the point cloud that is mainly attributed to its low computational efficiency. In this paper, a novel, fast method-based on bi-linear interpolation is reported on the normal vector estimation for LSSPC. We divide the point sets into many small cubes to speed up the local point search and construct interpolation nodes on the isosurface expressed by the point cloud. On the premise of calculating the normal vectors of these interpolated nodes, a normal vector bi-linear interpolation of the points in the cube is realized. The proposed approach has the merits of accurate, simple, and high efficiency, because the algorithm only needs to search neighbor and calculates normal vectors for interpolation nodes that are usually far less than the point cloud. The experimental results of several real and simulated point sets show that our method is over three times faster than the Elliptic Gabriel Graph-based method, and the average deviation is less than 0.01 mm.

  19. CMOS Cell Sensors for Point-of-Care Diagnostics

    Science.gov (United States)

    Adiguzel, Yekbun; Kulah, Haluk

    2012-01-01

    The burden of health-care related services in a global era with continuously increasing population and inefficient dissipation of the resources requires effective solutions. From this perspective, point-of-care diagnostics is a demanded field in clinics. It is also necessary both for prompt diagnosis and for providing health services evenly throughout the population, including the rural districts. The requirements can only be fulfilled by technologies whose productivity has already been proven, such as complementary metal-oxide-semiconductors (CMOS). CMOS-based products can enable clinical tests in a fast, simple, safe, and reliable manner, with improved sensitivities. Portability due to diminished sensor dimensions and compactness of the test set-ups, along with low sample and power consumption, is another vital feature. CMOS-based sensors for cell studies have the potential to become essential counterparts of point-of-care diagnostics technologies. Hence, this review attempts to inform on the sensors fabricated with CMOS technology for point-of-care diagnostic studies, with a focus on CMOS image sensors and capacitance sensors for cell studies. PMID:23112587

  20. Datum Feature Extraction and Deformation Analysis Method Based on Normal Vector of Point Cloud

    Science.gov (United States)

    Sun, W.; Wang, J.; Jin, F.; Liang, Z.; Yang, Y.

    2018-04-01

    In order to solve the problem lacking applicable analysis method in the application of three-dimensional laser scanning technology to the field of deformation monitoring, an efficient method extracting datum feature and analysing deformation based on normal vector of point cloud was proposed. Firstly, the kd-tree is used to establish the topological relation. Datum points are detected by tracking the normal vector of point cloud determined by the normal vector of local planar. Then, the cubic B-spline curve fitting is performed on the datum points. Finally, datum elevation and the inclination angle of the radial point are calculated according to the fitted curve and then the deformation information was analyzed. The proposed approach was verified on real large-scale tank data set captured with terrestrial laser scanner in a chemical plant. The results show that the method could obtain the entire information of the monitor object quickly and comprehensively, and reflect accurately the datum feature deformation.

  1. Point-of-Care Diagnostics on a Chip

    CERN Document Server

    Westervelt, Robert

    2013-01-01

    The topic of this book is the development of automated and inexpensive tools that transfer medical tests from a specialized clinical laboratory directly to the point of care, using biochip technology. Immediate access to medically relevant biochemical information for doctors and nurses promises to revolutionize patient care and dramatically lower costs. The miniaturization and automation of medical tests are made possible by biochip technology, that integrates advances in integrated circuits, microelectromechanical systems (MEMS), microfluidics, and electronics. The target audience for this book includes engineering and biomedical researchers who would like to develop or apply biochip technology. They can use this book as a review of the field and as a guide for the development of novel biochip technology for point of care medicine. This book can also be used as a teaching tool for engineering and biomedical students, as as well as a reference for physicians and health professionals.

  2. Challenges and Opportunities of Centrifugal Microfluidics for Extreme Point-of-Care Testing

    Directory of Open Access Journals (Sweden)

    Issac J. Michael

    2016-02-01

    Full Text Available The advantages offered by centrifugal microfluidic systems have encouraged its rapid adaptation in the fields of in vitro diagnostics, clinical chemistry, immunoassays, and nucleic acid tests. Centrifugal microfluidic devices are currently used in both clinical and point-of-care settings. Recent studies have shown that this new diagnostic platform could be potentially used in extreme point-of-care settings like remote villages in the Indian subcontinent and in Africa. Several technological inventions have decentralized diagnostics in developing countries; however, very few microfluidic technologies have been successful in meeting the demand. By identifying the finest difference between the point-of-care testing and extreme point-of-care infrastructure, this review captures the evolving diagnostic needs of developing countries paired with infrastructural challenges with technological hurdles to healthcare delivery in extreme point-of-care settings. In particular, the requirements for making centrifugal diagnostic devices viable in developing countries are discussed based on a detailed analysis of the demands in different clinical settings including the distinctive needs of extreme point-of-care settings.

  3. Diagnosing patients at point of care

    CSIR Research Space (South Africa)

    Vilakazi, CB

    2015-10-01

    Full Text Available of pregnant women, the Cellnostics portable blood analyser and paper-based diagnostic solutions. Umbiflow is a Doppler ultrasound device that can determine at the primary point of care, such as a clinic, whether a fetus that is small for gestational age...

  4. Effect of care management program structure on implementation: a normalization process theory analysis.

    Science.gov (United States)

    Holtrop, Jodi Summers; Potworowski, Georges; Fitzpatrick, Laurie; Kowalk, Amy; Green, Lee A

    2016-08-15

    Care management in primary care can be effective in helping patients with chronic disease improve their health status, however, primary care practices are often challenged with implementation. Further, there are different ways to structure care management that may make implementation more or less successful. Normalization process theory (NPT) provides a means of understanding how a new complex intervention can become routine (normalized) in practice. In this study, we used NPT to understand how care management structure affected how well care management became routine in practice. Data collection involved semi-structured interviews and observations conducted at 25 practices in five physician organizations in Michigan, USA. Practices were selected to reflect variation in physician organizations, type of care management program, and degree of normalization. Data were transcribed, qualitatively coded and analyzed, initially using an editing approach and then a template approach with NPT as a guiding framework. Seventy interviews and 25 observations were completed. Two key structures for care management organization emerged: practice-based care management where the care managers were embedded in the practice as part of the practice team; and centralized care management where the care managers worked independently of the practice work flow and was located outside the practice. There were differences in normalization of care management across practices. Practice-based care management was generally better normalized as compared to centralized care management. Differences in normalization were well explained by the NPT, and in particular the collective action construct. When care managers had multiple and flexible opportunities for communication (interactional workability), had the requisite knowledge, skills, and personal characteristics (skill set workability), and the organizational support and resources (contextual integration), a trusting professional relationship

  5. Barriers and decisions when answering clinical questions at the point of care: a grounded theory study.

    Science.gov (United States)

    Cook, David A; Sorensen, Kristi J; Wilkinson, John M; Berger, Richard A

    2013-11-25

    Answering clinical questions affects patient-care decisions and is important to continuous professional development. The process of point-of-care learning is incompletely understood. To understand what barriers and enabling factors influence physician point-of-care learning and what decisions physicians face during this process. Focus groups with grounded theory analysis. Focus group discussions were transcribed and then analyzed using a constant comparative approach to identify barriers, enabling factors, and key decisions related to physician information-seeking activities. Academic medical center and outlying community sites. Purposive sample of 50 primary care and subspecialist internal medicine and family medicine physicians, interviewed in 11 focus groups. Insufficient time was the main barrier to point-of-care learning. Other barriers included the patient comorbidities and contexts, the volume of available information, not knowing which resource to search, doubt that the search would yield an answer, difficulty remembering questions for later study, and inconvenient access to computers. Key decisions were whether to search (reasons to search included infrequently seen conditions, practice updates, complex questions, and patient education), when to search (before, during, or after the clinical encounter), where to search (with the patient present or in a separate room), what type of resource to use (colleague or computer), what specific resource to use (influenced first by efficiency and second by credibility), and when to stop. Participants noted that key features of efficiency (completeness, brevity, and searchability) are often in conflict. Physicians perceive that insufficient time is the greatest barrier to point-of-care learning, and efficiency is the most important determinant in selecting an information source. Designing knowledge resources and systems to target key decisions may improve learning and patient care.

  6. Study protocol: identifying and delivering point-of-care information to improve care coordination.

    Science.gov (United States)

    Hysong, Sylvia J; Che, Xinxuan; Weaver, Sallie J; Petersen, Laura A

    2015-10-19

    The need for deliberately coordinated care is noted by many national-level organizations. The Department of Veterans Affairs (VA) recently transitioned primary care clinics nationwide into Patient Aligned Care Teams (PACTs) to provide more accessible, coordinated, comprehensive, and patient-centered care. To better serve this purpose, PACTs must be able to successfully sequence and route interdependent tasks to appropriate team members while also maintaining collective situational awareness (coordination). Although conceptual frameworks of care coordination exist, few explicitly articulate core behavioral markers of coordination or the related information needs of team members attempting to synchronize complex care processes across time for a shared patient population. Given this gap, we partnered with a group of frontline primary care personnel at ambulatory care sites to identify the specific information needs of PACT members that will enable them to coordinate their efforts to provide effective, coordinated care. The study has three objectives: (1) development of measurable, prioritized point-of-care criteria for effective PACT coordination; (2) identifying the specific information needed at the point of care to optimize coordination; and (3) assessing the effect of adopting the aforementioned coordination standards on PACT clinicians' coordination behaviors. The study consists of three phases. In phase 1, we will employ the Productivity Measurement and Enhancement System (ProMES), a structured approach to performance measure creation from industrial/organizational psychology, to develop coordination measures with a design team of 6-10 primary care personnel; in phase 2, we will conduct focus groups with the phase 1 design team to identify point-of-care information needs. Phase 3 is a two-arm field experiment (n PACT = 28/arm); intervention arm PACTs will receive monthly feedback reports using the measures developed in phase 1 and attend brief monthly

  7. Point-of-care diagnostics: market trends and growth drivers.

    Science.gov (United States)

    Rajan, Aruna; Glorikian, Harry

    2009-01-01

    There is a significant demand for in vitro diagnostic (IVD) testing to move closer to the patient point-of-care diagnostics [POC]), whether in the hospital, physician's office, rapid clinic or the home, effectively cutting time to results and helping patients make better informed decisions about their health. To analyze the point-of-care market and its trends and growth drivers. In 2007, POC made up 30% of the IVD market and is expected to grow at 9% a year. Although the overall POC market is expected to grow steadily, infectious POC is now the most attractive segment. Availability of rapid random access molecular diagnostic system for critical care infectious diseases such as MRSA and sepsis in the near future is likely to be a significant driver of infectious POC post 2012. Owing to the extraordinary increase in the cost of care, healthcare delivery is moving to increasingly decentralized settings such as rapid clinics and the home, driven by point-of-care diagnostics that provide accurate and directional results. We are evolving from the analog testing world to the digital testing world, where diagnosis is exact and therapy can be administered and be predictably effective.

  8. Comparison of a gel column blood typing method and a point-of-care cartridge for dog erythrocyte antigen 1.1.

    Science.gov (United States)

    Blois, Shauna L; Richardson, Danielle M; Abrams-Ogg, Anthony C G

    2013-01-01

    Blood typing for the presence of Dog Erythrocyte Antigen (DEA) 1.1 is recommended in all donor and recipient dogs prior to transfusion of blood products. The objective of this study was to determine if a point-of-care DEA 1.1 blood typing cartridge could be used in place of the gel column typing method. Detection of DEA 1.1 was performed using a laboratory-based gel column method and a point-of-care cartridge. A convenience sample of 30 healthy blood donors, 13 dogs with immune-mediated hemolytic anemia (IMHA) (3 of which had concurrent immune-mediated thrombocytopenia [IMT]), and 44 dogs with other diseases was included in the study. Agreement was observed between the tests for normal dogs and dogs with nonimmune-mediated disease in 74/74 cases. Two dogs in the IMHA group had indeterminate gel column blood typing results; 1 dog in this group had a negative gel column test result but a positive cartridge test result. There was good agreement between the 2 methods for normal dogs and dogs with nonimmune-mediated disease. Blood typing methods in dogs with IMHA should be further investigated. © Veterinary Emergency and Critical Care Society 2013.

  9. Eighth International Chorea–Acanthocytosis Symposium: Summary of Workshop Discussion and Action Points

    Directory of Open Access Journals (Sweden)

    Samuel S. Pappas

    2017-02-01

    Full Text Available Chorea-Acanthocytosis (ChAc is a rare hereditary neurological disorder characterized by abnormal movements, red blood cell pathology, and progressive neurodegeneration. Little is understood of the pathogenesis of ChAc and related disorders (collectively Neuroacanthocytosis. The Eighth International Chorea-Acanthocytosis Symposium was held in May 2016 in Ann Arbor, MI, USA, and focused on molecular mechanisms driving ChAc pathophysiology. Accompanying the meeting, members of the neuroacanthocytosis research community and other invited scientists met in a workshop to discuss the current understanding and next steps needed to better understand ChAc pathogenesis. These discussions identified several broad and critical needs for advancing ChAc research and patient care, and led to the definition of 18 specific action points related to functional and molecular studies, animal models, and clinical research. These action points, described below, represent tractable research goals to pursue for the next several years.

  10. Normalized modes at selected points without normalization

    Science.gov (United States)

    Kausel, Eduardo

    2018-04-01

    As every textbook on linear algebra demonstrates, the eigenvectors for the general eigenvalue problem | K - λM | = 0 involving two real, symmetric, positive definite matrices K , M satisfy some well-defined orthogonality conditions. Equally well-known is the fact that those eigenvectors can be normalized so that their modal mass μ =ϕT Mϕ is unity: it suffices to divide each unscaled mode by the square root of the modal mass. Thus, the normalization is the result of an explicit calculation applied to the modes after they were obtained by some means. However, we show herein that the normalized modes are not merely convenient forms of scaling, but that they are actually intrinsic properties of the pair of matrices K , M, that is, the matrices already "know" about normalization even before the modes have been obtained. This means that we can obtain individual components of the normalized modes directly from the eigenvalue problem, and without needing to obtain either all of the modes or for that matter, any one complete mode. These results are achieved by means of the residue theorem of operational calculus, a finding that is rather remarkable inasmuch as the residues themselves do not make use of any orthogonality conditions or normalization in the first place. It appears that this obscure property connecting the general eigenvalue problem of modal analysis with the residue theorem of operational calculus may have been overlooked up until now, but which has in turn interesting theoretical implications.Á

  11. Point-of-Care Ultrasound: A Trend in Health Care.

    Science.gov (United States)

    Buerger, Anita M; Clark, Kevin R

    2017-11-01

    To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.

  12. ClinicalKey: a point-of-care search engine.

    Science.gov (United States)

    Vardell, Emily

    2013-01-01

    ClinicalKey is a new point-of-care resource for health care professionals. Through controlled vocabulary, ClinicalKey offers a cross section of resources on diseases and procedures, from journals to e-books and practice guidelines to patient education. A sample search was conducted to demonstrate the features of the database, and a comparison with similar tools is presented.

  13. Portable biosensors and point-of-care systems

    CERN Document Server

    Kintzios, Spyridon E

    2017-01-01

    This book describes the principles, design and applications of a new generation of analytical and diagnostic biomedical devices, characterized by their very small size, ease of use, multi-analytical capabilities and speed to provide handheld and mobile point-of-care (POC) diagnostics.

  14. Boiling point of volatile liquids at various pressures

    Directory of Open Access Journals (Sweden)

    Luisa Maria Valencia

    2017-07-01

    Full Text Available Water, under normal conditions, tends to boil at a “normal boiling temperature” at which the atmospheric pressure fixes the average amount of kinetic energy needed to reach its boiling point. Yet, the normal boiling temperature of different substances varies depending on their nature, for which substances like alcohols, known as volatile, boil faster than water under same conditions. In response to this phenomenon, an investigation on the coexistence of both gas and liquid phases of a volatile substance in a closed system was made, establishing vapor pressure as the determining tendency of a substance to vaporize, which increases exponentially with temperature until a critical point is reached. Since atmospheric pressure is fixed, the internal pressure of the system was varied to determine its relationship with vapor pressure and thus with the boiling point of the substance, concluding that the internal pressure and boiling point of a volatile liquid in a closed system are negatively proportional.

  15. In-vitro diagnostic devices introduction to current point-of-care diagnostic devices

    CERN Document Server

    Cheng, Chao-Min; Chen, Chien-Fu

    2016-01-01

    Addressing the origin, current status, and future development of point-of-care diagnostics, and serving to integrate knowledge and tools from Analytical Chemistry, Bioengineering, Biomaterials, and Nanotechnology, this book focusses on addressing the collective and combined needs of industry and academia (including medical schools) to effectively conduct interdisciplinary research. In addition to summarizing and detailing developed diagnostic devices, this book will attempt to point out the possible future trends of development for point-of-care diagnostics using both scientifically based research and practical engineering needs with the aim to help novices comprehensively understand the development of point-of-care diagnostics. This includes demonstrating several common but critical principles and mechanisms used in point-of-care diagnostics that address practical needs (e.g., disease or healthcare monitoring) using two well-developed examples so far: 1) blood glucose meters (via electrochemistry); and, 2) p...

  16. Quality indicators for international benchmarking of mental health care

    DEFF Research Database (Denmark)

    Hermann, Richard C; Mattke, Soeren; Somekh, David

    2006-01-01

    To identify quality measures for international benchmarking of mental health care that assess important processes and outcomes of care, are scientifically sound, and are feasible to construct from preexisting data.......To identify quality measures for international benchmarking of mental health care that assess important processes and outcomes of care, are scientifically sound, and are feasible to construct from preexisting data....

  17. A centrifugal microfluidic platform for point-of-care diagnostic applications

    Directory of Open Access Journals (Sweden)

    Suzanne Hugo

    2014-02-01

    Full Text Available Microfluidic systems enable precise control over tiny volumes of fluid in a compact and low-cost form, thus providing the ideal platform on which to develop point-of-care diagnostic solutions. Centrifugal microfluidic systems, also referred to as lab-on-a-disc or lab-on-a-CD systems, provide a particularly attractive solution for the implementation of microfluidic point-of-care diagnostic solutions as a result of their simple and compact instrumentation, as well as their functional diversity. Here we detail the implementation of a centrifugal microfluidic platform the first of its kind in South Africa as a foundation for the development of point-of-care diagnostic applications for which both the need and impact is great. The centrifugal microfluidic platform consists of three main components: a microfluidic disc device similar in size and shape to a CD, a system for controlling fluid flow on the device, and a system for recording the results obtained. These components have been successfully implemented and tested. Preliminary test results show that microfluidic functions such as pumping and valving of fluids can be successfully achieved, as well as the generation of monodisperse microfluidic droplets, providing a complete centrifugal microfluidic platform and the building blocks on which to develop a variety of applications, including point-of-care diagnostics. The lab-on-a-disc platform has the potential to provide new diagnostic solutions at the point-of-need in health- and industry-related areas. This paves the way for providing resource limited areas with services such as improved, decentralised health-care access or water-quality monitoring, and reduced diagnosis times at a low cost.

  18. Curricula and Organization of Primary Care Residencies in Internal Medicine.

    Science.gov (United States)

    Eisenberg, John M.

    1980-01-01

    The organization and curricula of internal medicine residencies programs that emphasize primary care are described and compared with traditional residencies in internal medicine. It is noted that primary care residents spend more time in ambulatory care and are allowed more electives in specialties outside of internal medicine. Out-of-hospital…

  19. Point-of-care diagnosis of periodontitis using saliva: technically feasible but still a challenge

    Directory of Open Access Journals (Sweden)

    Suk eJi

    2015-09-01

    Full Text Available Periodontitis is a chronic inflammation of the periodontium caused by persistent bacterial infection that leads to the breakdown of connective tissue and bone. Because the ability to reconstruct the periodontium is limited after alveolar bone loss, early diagnosis and intervention should be the primary goals of periodontal treatment. However, periodontitis often progresses without noticeable symptoms, and many patients do not seek professional dental care until the periodontal destruction progresses to the point of no return. Furthermore, the current diagnosis of periodontitis depends on time-consuming clinical measurements. Therefore, there is an unmet need for near-patient testing to diagnose periodontitis. Saliva is an optimal biological fluid to serve as a near-patient diagnostic tool for periodontitis. Recent developments in point-of-care (POC testing indicate that a diagnostic test for periodontitis using saliva is now technically feasible. A number of promising salivary biomarkers associated with periodontitis have been reported. A panel of optimal biomarkers must be carefully selected based on the pathogenesis of periodontitis. The biggest hurdle for the POC diagnosis of periodontitis using saliva may be the process of validation in a large, diverse patient population. Therefore, we propose the organization of an International Consortium for Biomarkers of Periodontitis, which will gather efforts to identify, select, and validate salivary biomarkers for the diagnosis of periodontitis.

  20. [The quality of the German health-care system in an international comparison - a systematic review].

    Science.gov (United States)

    Lauerer, M; Emmert, M; Schöffski, O

    2013-08-01

    Studies assessing the quality of the German health-care system in an international comparison come to different results. Therefore, this review aims to investigate how the German health-care system is evaluated in comparison to other health-care systems by reviewing international publications. Results show starting points for ways to improve the German health-care system, to maintain and expand its strengths as well as to derive strategies for solving identified problems. A systematic review searching different databases [library catalogues, WorldCat (including MEDLINE and OAIster-search), German National Library, Google Scholar and others]. Search requests were addressed to English or German language publications for the time period 2000-2010 (an informal search was conducted in October 2011 for an update). Results of the identified studies were aggregated and main statements derived. In total, 13 publications assessing the German health-care system in an international comparison were identified. These comparisons are based on 377 measures. After aggregation, 244 substantially different indicators remained, which were dedicated to 14 categories. It became apparent that the German health-care system can be characterised by a high level of expenses, a well-developed health-care infrastructure as well as a high availability of personal and material resources. Outcome measures demonstrate heterogeneous results. It can be stated that, particularly in this field, there is potential for further improvement. The utilisation of health-care services is high, the access is mostly not regulated and out of pocket payments can pose a barrier for patients. Waiting times are not regarded as a major weakness. Although civic satisfaction seems to be acceptable, a large portion of the citizens calls for elementary modifications. Especially, more patient-centred health-care delivery should be addressed as well as management of information and the adoption of meaningful electronic

  1. Advancing Normal Birth: Organizations, Goals, and Research

    OpenAIRE

    Hotelling, Barbara A.; Humenick, Sharron S.

    2005-01-01

    In this column, the support for advancing normal birth is summarized, based on a comparison of the goals of Healthy People 2010, Lamaze International, the Coalition for Improving Maternity Services, and the midwifery model of care. Research abstracts are presented to provide evidence that the midwifery model of care safely and economically advances normal birth. Rates of intervention experienced, as reported in the Listening to Mothers survey, are compared to the forms of care recommended by ...

  2. Nursing Reference Center: a point-of-care resource.

    Science.gov (United States)

    Vardell, Emily; Paulaitis, Gediminas Geddy

    2012-01-01

    Nursing Reference Center is a point-of-care resource designed for the practicing nurse, as well as nursing administrators, nursing faculty, and librarians. Users can search across multiple resources, including topical Quick Lessons, evidence-based care sheets, patient education materials, practice guidelines, and more. Additional features include continuing education modules, e-books, and a new iPhone application. A sample search and comparison with similar databases were conducted.

  3. Osmotic actuation for microfluidic components in point-of-care applications

    KAUST Repository

    Chen, Yu-Chih

    2013-01-01

    We present a novel design of micropumps and valves driven by osmotic force for point-of-care applications. Although there have been significant progresses in microfluidic components and control devices such as fluidic diodes, switches, resonators and digital-to-analog converters, the ultimate power source still depends on bulky off-chip components, which are expensive and cannot be easily miniaturized. For point-of-care applications, it is critical to integrate all the components in a compact size at low cost. In this work, we report two key active components actuated by osmotic mechanism for total integrated microfluidic system. For the proof of concept, we have demonstrated valve actuation, which can maintain stable ON/OFF switching operations under 125 kPa back pressure. We have also implemented an osmotic pump, which can pump a high flow rate over 30 μL/min for longer than 30 minutes. The experimental data demonstrates the possibility and potential of applying osmotic actuation in point-of-care disposable microfluidics. © 2013 IEEE.

  4. Development and internal validation of the Simplified Mortality Score for the Intensive Care Unit (SMS-ICU)

    DEFF Research Database (Denmark)

    Granholm, A.; Perner, A.; Krag, M.

    2018-01-01

    Background: Intensive care unit (ICU) mortality prediction scores deteriorate over time, and their complexity decreases clinical applicability and commonly causes problems with missing data. We aimed to develop and internally validate a new and simple score that predicts 90-day mortality in adults...... upon acute admission to the ICU: the Simplified Mortality Score for the Intensive Care Unit (SMS-ICU). Methods: We used data from an international cohort of 2139 patients acutely admitted to the ICU and 1947 ICU patients with severe sepsis/septic shock from 2009 to 2016. We performed multiple...... imputations for missing data and used binary logistic regression analysis with variable selection by backward elimination, followed by conversion to a simple point-based score. We assessed the apparent performance and validated the score internally using bootstrapping to present optimism-corrected performance...

  5. Urachal Cyst Diagnosed by Point-of-care Ultrasound

    Directory of Open Access Journals (Sweden)

    Vigil James

    2017-10-01

    Full Text Available Irreducible umbilical swelling in infants is considered a surgical emergency because a delay in surgical intervention for an incarcerated umbilical hernia can lead to bowel ischemia and necrosis. We report two patients who presented to a pediatric emergency department with history and symptoms of irreducible umbilical mass suggestive of umbilical hernia. Point-of-care ultrasound was used at the bedside to demonstrate the presence of urachal cyst remnants and accurately guided the care of these children.

  6. On the critical temperature, normal boiling point, and vapor pressure of ionic liquids.

    Science.gov (United States)

    Rebelo, Luis P N; Canongia Lopes, José N; Esperança, José M S S; Filipe, Eduardo

    2005-04-07

    One-stage, reduced-pressure distillations at moderate temperature of 1-decyl- and 1-dodecyl-3-methylimidazolium bistriflilamide ([Ntf(2)](-)) ionic liquids (ILs) have been performed. These liquid-vapor equilibria can be understood in light of predictions for normal boiling points of ILs. The predictions are based on experimental surface tension and density data, which are used to estimate the critical points of several ILs and their corresponding normal boiling temperatures. In contrast to the situation found for relatively unstable ILs at high-temperature such as those containing [BF(4)](-) or [PF(6)](-) anions, [Ntf(2)](-)-based ILs constitute a promising class in which reliable, accurate vapor pressure measurements can in principle be performed. This property is paramount for assisting in the development and testing of accurate molecular models.

  7. Does point-of-care functional echocardiography enhance cardiovascular care in the NICU?

    Science.gov (United States)

    Sehgal, A; McNamara, P J

    2008-11-01

    Although the last two decades have seen major advances in the care of sick, extremely premature newborns, the approach to cardiovascular assessment and monitoring remains suboptimal owing to an overreliance on poorly predictive clinical markers such as heart rate or capillary refill time. Point-of-care functional echocardiography (PCFecho) enables real-time evaluation of cardiac performance and systemic hemodynamics to characterize acute physiology, identify the exact nature of cardiovascular compromise and guide therapeutic decisions. In this article, we will review four clinical scenarios where bedside functional cardiac imaging enabled delineation of the real clinical problem and refinement of the therapeutic care plan with direct patient benefits.

  8. Comparability of Point-of-Care versus Central Laboratory Hemoglobin Determination in Emergency Patients at a Supra-Maximal Care Hospital.

    Science.gov (United States)

    Dolscheid-Pommerich, Ramona C; Dolscheid, Sarah; Grigutsch, Daniel; Stoffel-Wagner, Birgit; Graeff, Ingo

    2016-01-01

    Fulfilling the requirements of point-of-care testing (POCT) training regarding proper execution of measurements and compliance with internal and external quality control specifications is a great challenge. Our aim was to compare the values of the highly critical parameter hemoglobin (Hb) determined with POCT devices and central laboratory analyzer in the highly vulnerable setting of an emergency department in a supra maximal care hospital to assess the quality of POCT performance. In 2548 patients, Hb measurements using POCT devices (POCT-Hb) were compared with Hb measurements performed at the central laboratory (Hb-ZL). Additionally, sub collectives (WHO anemia classification, patients with Hb 85y.) were analyzed. Overall, the correlation between POCT-Hb and Hb-ZL was highly significant (r = 0.96, p2.5g/dl occurred. McNemar´s test revealed significant differences regarding anemia diagnosis according to WHO definition for male, female and total patients (♂ phemoglobin concentration measurement methods, i.e. POCT devices and at the central laboratory. The results confirm the successful implementation of the presented POCT concept. Nevertheless some limitations could be identified in anemic patients stressing the importance of carefully examining clinically implausible results.

  9. ClinicalKey 2.0: Upgrades in a Point-of-Care Search Engine.

    Science.gov (United States)

    Huslig, Mary Ann; Vardell, Emily

    2015-01-01

    ClinicalKey 2.0, launched September 23, 2014, offers a mobile-friendly design with a search history feature for targeting point-of-care resources for health care professionals. Browsing is improved with searchable, filterable listings of sources highlighting new resources. ClinicalKey 2.0 improvements include more than 1,400 new Topic Pages for quick access to point-of-care content. A sample search details some of the upgrades and content options.

  10. Comparison of International Normalized Ratio Measurement between CoaguChek XS Plus and STA-R Coagulation Analyzers

    Directory of Open Access Journals (Sweden)

    Mina Hur

    2013-01-01

    Full Text Available Background. Point-of-care testing (POCT coagulometers are increasingly being used in the hospital setting. We investigated whether the prothrombin time international normalized ratio (INR results by CoaguChek XS Plus (Roche Diagnostics GmbH, Mannheim, Germany can be used reliably without being confirmed with the INR results by STA-R system (Diagnostica Stago S.A.S, Asnières sur Seine, France. Methods. A total of 118 INR measurements by CoaguChek XS Plus and STA-R were compared using Passing/Bablok regression analysis and Bland-Altman plot. Agreement of the INR measurements was further assessed in relation to dosing decision. Results. The correlation of INR measurements between CoaguChek XS Plus and STA-R was excellent (correlation coefficient = 0.964. The mean difference tended to increase as INR results increased and was 0.25 INR in the therapeutic range (2.0-3.0 INR. The overall agreement was fair to good (kappa = 0.679, and 21/118 (17.8% INR measurements showed a difference in dosing decision. Conclusion. The positive bias of CoaguChek XS Plus may be obvious even in the therapeutic INR range, and dosing decision based on the CoaguChek XS Plus INR results would be different from that based on the STA-R results. The INR measurements by POCT coagulometers still need to be confirmed with the laboratory INR measurements.

  11. Evaluation of point-of-care test for elevated tear matrix metalloproteinase 9 in post-LASIK dry eyes.

    Science.gov (United States)

    Chan, Tommy C Y; Ye, Cong; Chan, Kwok Ping; Chu, Kai On; Jhanji, Vishal

    2016-09-01

    To evaluate the performance of a point-of-care test for detection of matrix metalloproteinase 9 (MMP-9) levels in post-laser-assisted in situ keratomileusis (LASIK) dry eyes. A comparative study between patients with mild to moderate post-LASIK dry eyes and age-matched normal subjects was conducted. Ocular surface disease index (OSDI), tear break-up time (TBUT), and tear film MMP-9 and total protein levels were compared between the two groups. A point-of-care test device (RPS InflammaDry, Sarasota, Florida, USA) was utilised to confirm elevated MMP-9 levels in tear film. Fourteen post-LASIK dry eyes and 34 normal eyes were included. There was no significant difference in age and gender between both groups (p>0.175). The OSDI was significantly higher (25.5±7.7 vs 7.4±2.5; pdry eye compared with normal subjects. The tear film MMP-9 levels were 52.7±32.5 ng/mL in dry eyes and 4.1±2.1 ng/mL in normal eyes (p40 ng/mL in 7/14 (50.0%) post-LASIK dry eyes. The InflammaDry was positive in 8/14 (57.1%) post-LASIK eyes. All positive cases had tear film MMP-9 levels ≥38.03 ng/mL. Agreement between InflammaDry and MMP-9 was excellent with Cohen κ value of 0.857 in post-LASIK dry eyes. Only half of post-LASIK dry eyes were found to have significant inflammation associated with elevated MMP-9. The OSDI is useful to non-specifically identify patients with symptomatic dry eye while the InflammaDry determined which patients with dry eye were associated with significant inflammation that may guide therapeutic management decisions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Science.gov (United States)

    2010-10-01

    ...) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of operation in internal transmitter control systems. The... licensee for internal communications and transmitter control purposes. Operating positions in internal...

  13. Microbiological point of care testing before antibiotic prescribing in primary care

    DEFF Research Database (Denmark)

    Haldrup, Steffen; Thomsen, Reimar W.; Bro, Flemming

    2017-01-01

    BACKGROUND: Point-of-care testing (POCT) in primary care may improve rational antibiotic prescribing. We examined use of POCT in Denmark, including patient- and general practitioner (GP)-related predictors. METHODS: We linked nationwide health care databases to assess POCT use (C-reactive protein...... (CRP), group A streptococcal (GAS) antigen swabs, bacteriological cultures, and urine test strips) per 1,000 overall GP consultations, 2004-2013. We computed odds ratios (OR) of POCT in patients prescribed antibiotics according to patient and GP age and sex, GP practice type, location, and workload....... RESULTS: The overall use of POCT in Denmark increased by 45.8% during 2004-2013, from 147.2 per 1,000 overall consultations to 214.8. CRP tests increased by 132%, bacteriological cultures by 101.7% while GAS swabs decreased by 8.6%. POCT preceded 28% of antibiotic prescriptions in 2004 increasing to 44...

  14. "I Treat Him as a Normal Patient": Unveiling the Normalization Coping Strategy Among Formal Caregivers of Persons With Dementia and Its Implications for Person-Centered Care.

    Science.gov (United States)

    Bentwich, Miriam Ethel; Dickman, Nomy; Oberman, Amitai; Bokek-Cohen, Ya'arit

    2017-11-01

    Currently, 47 million people have dementia, worldwide, often requiring paid care by formal caregivers. Research regarding family caregivers suggests normalization as a model for coping with negative emotional outcomes in caring for a person with dementia (PWD). The study aims to explore whether normalization coping mechanism exists among formal caregivers, reveal differences in its application among cross-cultural caregivers, and examine how this coping mechanism may be related to implementing person-centered care for PWDs. Content analysis of interviews with 20 formal caregivers from three cultural groups (Jews born in Israel [JI], Arabs born in Israel [AI], Russian immigrants [RI]), attending to PWDs. We extracted five normalization modes, revealing AI caregivers had substantially more utterances of normalization expressions than their colleagues. The normalization modes most commonly expressed by AI caregivers relate to the personhood of PWDs. These normalization modes may enhance formal caregivers' ability to employ person-centered care.

  15. Perceptions of point-of-care infectious disease testing among European medical personnel, point-of-care test kit manufacturers, and the general public

    NARCIS (Netherlands)

    W.E. Kaman (Wendy); E-R. Andrinopoulou (Eleni-Rosalina); J.P. Hays (John)

    2013-01-01

    textabstractBackground: The proper development and implementation of point-of-care (POC) diagnostics requires knowledge of the perceived requirements and barriers to their implementation. To determine the current requirements and perceived barriers to the introduction of POC diagnostics in the field

  16. Operationalizing Semantic Medline for meeting the information needs at point of care

    Science.gov (United States)

    Rastegar-Mojarad, Majid; Li, Dingcheng; Liu, Hongfang

    2015-01-01

    Scientific literature is one of the popular resources for providing decision support at point of care. It is highly desirable to bring the most relevant literature to support the evidence-based clinical decision making process. Motivated by the recent advance in semantically enhanced information retrieval, we have developed a system, which aims to bring semantically enriched literature, Semantic Medline, to meet the information needs at point of care. This study reports our work towards operationalizing the system for real time use. We demonstrate that the migration of a relational database implementation to a NoSQL (Not only SQL) implementation significantly improves the performance and makes the use of Semantic Medline at point of care decision support possible. PMID:26306259

  17. Operationalizing Semantic Medline for meeting the information needs at point of care.

    Science.gov (United States)

    Rastegar-Mojarad, Majid; Li, Dingcheng; Liu, Hongfang

    2015-01-01

    Scientific literature is one of the popular resources for providing decision support at point of care. It is highly desirable to bring the most relevant literature to support the evidence-based clinical decision making process. Motivated by the recent advance in semantically enhanced information retrieval, we have developed a system, which aims to bring semantically enriched literature, Semantic Medline, to meet the information needs at point of care. This study reports our work towards operationalizing the system for real time use. We demonstrate that the migration of a relational database implementation to a NoSQL (Not only SQL) implementation significantly improves the performance and makes the use of Semantic Medline at point of care decision support possible.

  18. Characterization of microfluidic components for low-cost point-of-care devices

    CSIR Research Space (South Africa)

    Hugo

    2013-10-01

    Full Text Available -of-care diagnostic systems, particularly in under-resourced settings to enable instant diagnosis and improve healthcare. Although numerous and varied advances in the field of microfluidics have enabled point-of-care systems to be realized, there is often a trade...

  19. Quality assurance for HIV point-of-care testing and treatment monitoring assays

    Directory of Open Access Journals (Sweden)

    Adrienne F.A. Meyers

    2016-10-01

    Full Text Available In 2015, UNAIDS launched the 90-90-90 targets aimed at increasing the number of peopleinfected with HIV to become aware of their status, access antiretroviral therapies and ultimatelybe virally suppressed. To achieve these goals, countries may need to scale up point-of-care (POC testing in addition to strengthening central laboratory services. While decentralisingtesting increases patient access to diagnostics, it presents many challenges with regard totraining and assuring the quality of tests and testing. To ensure synergies, the London Schoolof Hygiene & Tropical Medicine held a series of consultations with countries with an interestin quality assurance and their implementing partners, and agreed on an external qualityassessment (EQA programme to ensure reliable results so that the results lead to the bestpossible care for HIV patients. As a result of the consultations, EQA International wasestablished, bringing together EQA providers and implementers to develop a strategic planfor countries to establish national POC EQA programmes and to estimate the cost of setting upand maintaining the programme. With the dramatic increase in the number of proficiencytesting panels required for thousands of POC testing sites across Africa, it is important tofacilitate technology transfer from global EQA providers to a network of regional EQA centresin Africa for regional proficiency testing panel production. EQA International will continue toidentify robust and cost-effective EQA technologies for quality POC testing, integrating noveltechnologies to support sustainable country-owned EQA programmes in Africa.

  20. Care model design for E-health : Integration of point-of-care testing at Dutch general practices

    NARCIS (Netherlands)

    Verhees, Bart; van Kuijk, Kees; Simonse, W.L.

    2018-01-01

    Point-of-care testing (POCT)—laboratory tests performed with new mobile devices and online technologies outside of the central laboratory—is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by

  1. Point-of-Care Testing: General Aspects.

    Science.gov (United States)

    Ferreira, Carlos E S; Guerra, Joao C C; Slhessarenko, Natasha; Scartezini, Marileia; Franca, Carolina N; Colombini, Marjorie P; Berlitz, Fernando; Machado, Antonia M O; Campana, Gustavo A; Faulhaber, Adriana C L; Galoro, Cesar A; Dias, Claudia M; Shcolnik, Wilson; Martino, Marines D V; Cesar, Katia R; Sumita, Nairo M; Mendes, Maria E; Faulhaber, Marcelo H W; Pinho, Joao R R; Barbosa, Ismar V; Batista, Marcelo C; Khawali, Cristina; Pariz, Vitor M; Andriolo, Adagmar

    2018-01-01

    Point-of-Care Testing (POCT) has been highlighted in the health care sector in recent decades. On the other hand, due to its low demand, POCT is at a disadvantage compared to conventional equipment, since its cost is inversely proportional to the volume of use. In addition, for the implementation of POCT to succeed, it is essential to rely on the work of a multidisciplinary team. The awareness of health professionals of the importance of each step is perhaps the critical success factor. The trend towards the continuous advancement of the use of POCT and the great potential of its contributions reinforce the need to implement quality management tools, including performance indicators, to ensure their results. This review presents some advantages and disadvantages concerning POCT and the real need to use it. A worldwide call for the availability of easy-to-use health technologies that are increasingly closer to the final user is one of the main reasons for this focus.

  2. Tracking the progress of HIV: the impact of point-of-care tests on antiretroviral therapy

    Directory of Open Access Journals (Sweden)

    Reid SD

    2013-09-01

    Full Text Available Steven D Reid, Sarah J Fidler, Graham S Cooke Department of Infectious Diseases, St Mary's Hospital, Imperial College London, London, UK Abstract: It is now around 30 years since the discovery of HIV, the virus that causes AIDS. More than 70 million people have been infected in that time and around 35 million have died. The majority of those currently living with HIV/AIDS are in low- and middle-income countries, with sub-Saharan Africa bearing a disproportionate burden of the global disease. In high-income countries, the introduction of antiretroviral therapy (ART has drastically reduced the morbidity and mortality associated with HIV. Patients on ART are now predicted to have near-normal life expectancy and the role of treatment is increasingly recognized in preventing new infections. In low- and middle-income countries, treatment is now more widely available and around half of those who need ART are currently receiving it. Early diagnosis of HIV is essential if ART is to be optimally implemented. Lab-based diagnostics for screening, diagnosis, treatment initiation, and the monitoring of treatment efficacy are critical in managing the disease and reducing the number of new infections each year. The introduction of point-of-care HIV rapid tests has transformed the epidemic, particularly in low- and middle-income countries. For the first time, these point-of-care tests allow for the rapid identification of infected individuals outside the laboratory who can undergo counseling and treatment and, in the case of pregnant women, allow the timely initiation of ART to reduce the risk of vertical transmission. Although survival is markedly improved with ART even in the absence of laboratory monitoring, long-term management of people living with HIV on ART, and their partners, is essential to ensure successful viral suppression. The burden of disease in many resource-poor settings with high HIV prevalence has challenged the ability of local laboratories

  3. The strength of primary care in Europe: an international comparative study.

    Science.gov (United States)

    Kringos, Dionne; Boerma, Wienke; Bourgueil, Yann; Cartier, Thomas; Dedeu, Toni; Hasvold, Toralf; Hutchinson, Allen; Lember, Margus; Oleszczyk, Marek; Rotar Pavlic, Danica; Svab, Igor; Tedeschi, Paolo; Wilm, Stefan; Wilson, Andrew; Windak, Adam; Van der Zee, Jouke; Groenewegen, Peter

    2013-11-01

    A suitable definition of primary care to capture the variety of prevailing international organisation and service-delivery models is lacking. Evaluation of strength of primary care in Europe. International comparative cross-sectional study performed in 2009-2010, involving 27 EU member states, plus Iceland, Norway, Switzerland, and Turkey. Outcome measures covered three dimensions of primary care structure: primary care governance, economic conditions of primary care, and primary care workforce development; and four dimensions of primary care service-delivery process: accessibility, comprehensiveness, continuity, and coordination of primary care. The primary care dimensions were operationalised by a total of 77 indicators for which data were collected in 31 countries. Data sources included national and international literature, governmental publications, statistical databases, and experts' consultations. Countries with relatively strong primary care are Belgium, Denmark, Estonia, Finland, Lithuania, the Netherlands, Portugal, Slovenia, Spain, and the UK. Countries either have many primary care policies and regulations in place, combined with good financial coverage and resources, and adequate primary care workforce conditions, or have consistently only few of these primary care structures in place. There is no correlation between the access, continuity, coordination, and comprehensiveness of primary care of countries. Variation is shown in the strength of primary care across Europe, indicating a discrepancy in the responsibility given to primary care in national and international policy initiatives and the needed investments in primary care to solve, for example, future shortages of workforce. Countries are consistent in their primary care focus on all important structure dimensions. Countries need to improve their primary care information infrastructure to facilitate primary care performance management.

  4. Point of care hematocrit and hemoglobin in cardiac surgery: a review.

    Science.gov (United States)

    Myers, Gerard J; Browne, Joe

    2007-05-01

    The use of point-of-care blood gas analyzers in cardiac surgery has been on the increase over the past decade. The availability of these analyzers in the operating room and post-operative intensive care units eliminates the time delays to transport samples to the main laboratory and reduces the amount of blood sampled to measure such parameters as electrolytes, blood gases, lactates, glucose and hemoglobin/hematocrit. Point-of-care analyzers also lead to faster and more reliable clinical decisions while the patient is still on the heart lung machine. Point-of-care devices were designed to provide safe, appropriate and consistent care of those patients in need of rapid acid/base balance and electrolyte management in the clinical setting. As a result, clinicians rely on their values to make decisions regarding ventilation, acid/base management, transfusion and glucose management. Therefore, accuracy and reliability are an absolute must for these bedside analyzers in both the cardiac operating room and the post-op intensive care units. Clinicians have a choice of two types of technology to measure hemoglobin/hematocrit during bypass, which subsequently determines their patient's level of hemodilution, as well as their transfusion threshold. All modern point-of-care blood gas analyzers measure hematocrit using a technology called conductivity, while other similar devices measure hemoglobin using a technology called co-oximetry. The two methods are analyzed and compared in this review. The literature indicates that using conductivity to measure hematocrit during and after cardiac surgery could produce inaccurate results when hematocrits are less than 30%, and, therefore, result in unnecessary homologous red cell transfusions in some patients. These inaccuracies are influenced by several factors that are common and unique to cardiopulmonary bypass, and will also be reviewed here. It appears that the only accurate, consistent and reliable method to determine hemodilution

  5. Seeking health care through international medical tourism.

    Science.gov (United States)

    Eissler, Lee Ann; Casken, John

    2013-06-01

    The purpose of this study was the exploration of international travel experiences for the purpose of medical or dental care from the perspective of patients from Alaska and to develop insight and understanding of the essence of the phenomenon of medical tourism. The study is conceptually oriented within a model of health-seeking behavior. Using a qualitative design, 15 Alaska medical tourists were individually interviewed. The data were analyzed using a hermeneutic process of inquiry to uncover the meaning of the experience. Six themes reflecting the experiences of Alaska medical tourists emerged: "my motivation," "I did the research," "the medical care I need," "follow-up care," "the advice I give," and "in the future." Subthemes further categorized data for increased understanding of the phenomenon. The thematic analysis provides insight into the experience and reflects a modern approach to health-seeking behavior through international medical tourism. The results of this study provide increased understanding of the experience of obtaining health care internationally from the patient perspective. Improved understanding of medical tourism provides additional information about a contemporary approach to health-seeking behavior. Results of this study will aid nursing professionals in counseling regarding medical tourism options and providing follow-up health care after medical tourism. Nurses will be able to actively participate in global health policy discussions regarding medical tourism trends. © 2013 Sigma Theta Tau International.

  6. Community governance in primary health care: towards an international Ideal Type.

    Science.gov (United States)

    Meads, Geoffrey; Russell, Grant; Lees, Amanda

    2017-10-01

    Against a global background of increased resource management responsibilities for primary health care agencies, general medical practices, in particular, are increasingly being required to demonstrate the legitimacy of their decision making in market oriented environments. In this context a scoping review explores the potential utility for health managers in primary health care of community governance as a policy concept. The review of recent research suggests that applied learning from international health systems with enhanced approaches to public and patient involvement may contribute to meeting this requirement. Such approaches often characterise local health systems in Latin America and North West Europe where innovative models are beginning to respond effectively to the growing demands on general practice. The study design draws on documentary and secondary data analyses to identify common components of community governance from the countries in these regions, supplemented by other relevant international studies and sources where appropriate. Within a comprehensive framework of collaborative governance the components are aggregated in an Ideal Type format to provide a point of reference for possible adaptation and transferable learning across market oriented health systems. Each component is illustrated with international exemplars from recent organisational practices in primary health care. The application of community governance is considered for the particular contexts of GP led Clinical Commissioning Groups in England and Primary Health Networks in Australia. Some components of the Ideal Type possess potentially powerful negative as well as positive motivational effects, with PPI at practice levels sometimes hindering the development of effective local governance. This highlights the importance of careful and competent management of the growing resources attributed to primary health care agencies, which possess an increasingly diverse range of non

  7. Analytical evaluation of a new point of care system for measuring cardiac Troponin I

    NARCIS (Netherlands)

    Kemper, D.W.; Semjonow, V.; de Theije, F.; Keizer, D.; van Lippen, L.; Mair, J.; Wille, B.; Christ, M.; Geijer, F.; Hausfater, P.; Pariente, D.; Scharnhorst, V.; Curvers, J.; Nieuwenhuis, J.

    2017-01-01

    OBJECTIVES: Point-of-care cardiac troponin testing with adequate analytical performances has the potential to improve chest pain patients flow in the emergency department. We present the analytical evaluation of the newly developed Philips Minicare cTnI point-of-care immunoassay. DESIGN & METHODS:

  8. 46 CFR 401.428 - Basic rates and charges for carrying a U.S. pilot beyond normal change point or for boarding at...

    Science.gov (United States)

    2010-10-01

    ... boarding point, the ship shall pay at the rate of $719 per day or part thereof, plus reasonable travel... normal change point or for boarding at other than the normal boarding point. 401.428 Section 401.428... carrying a U.S. pilot beyond normal change point or for boarding at other than the normal boarding point...

  9. Risk Management for Point-of-Care Testing

    OpenAIRE

    James, H. Nichols

    2014-01-01

    Point-of-care testing (POCT) is growing in popularity, and with this growth comes an increased chance of errors. Risk management is a way to reduce errors. Originally developed for the manufacturing industry, risk management principles have application for improving the quality of test results in the clinical laboratory. The Clinical and Laboratory Standards Institute (CLSI), EP23-A Laboratory Quality Control based on Risk Management guideline, introduces risk management to the clinical labor...

  10. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection

    OpenAIRE

    Lau, Han Yih; Botella, Jose R.

    2017-01-01

    Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care di...

  11. Quality assurance for HIV point-of-care testing and treatment monitoring assays

    Science.gov (United States)

    Sandstrom, Paul; Denny, Thomas N.; Hurlston, Mackenzie; Ball, Terry B.; Peeling, Rosanna W.; Boeras, Debrah I.

    2016-01-01

    In 2015, UNAIDS launched the 90-90-90 targets aimed at increasing the number of people infected with HIV to become aware of their status, access antiretroviral therapies and ultimately be virally suppressed. To achieve these goals, countries may need to scale up point-of-care (POC) testing in addition to strengthening central laboratory services. While decentralising testing increases patient access to diagnostics, it presents many challenges with regard to training and assuring the quality of tests and testing. To ensure synergies, the London School of Hygiene & Tropical Medicine held a series of consultations with countries with an interest in quality assurance and their implementing partners, and agreed on an external quality assessment (EQA) programme to ensure reliable results so that the results lead to the best possible care for HIV patients. As a result of the consultations, EQA International was established, bringing together EQA providers and implementers to develop a strategic plan for countries to establish national POC EQA programmes and to estimate the cost of setting up and maintaining the programme. With the dramatic increase in the number of proficiency testing panels required for thousands of POC testing sites across Africa, it is important to facilitate technology transfer from global EQA providers to a network of regional EQA centres in Africa for regional proficiency testing panel production. EQA International will continue to identify robust and cost-effective EQA technologies for quality POC testing, integrating novel technologies to support sustainable country-owned EQA programmes in Africa. PMID:28879133

  12. Internal marketing strategy: Focusing on staff orientation in health care in South Africa

    Directory of Open Access Journals (Sweden)

    J. W. De Jager

    2008-12-01

    Full Text Available Purpose: The purpose of the paper is to determine the levels of satisfaction in respect of pre identified internal marketing-related variables in a large provincial hospital in South Africa. Problem investigated: Low job satisfaction is often cited as a major cause of high turnover among health care providers worldwide. Likewise the Public Health Care Industry in South Africa is facing complex employee retention issues. In determining the reasons for high turnover an interest in evaluating employee satisfaction among health care providers has increased. Measuring components of job satisfaction will assist not only the health care organisations' management to understand hospital culture, but also to compile an effective internal marketing plan and strategy. Design/Methodology/Approach: A staff satisfaction survey was conducted amongst staff members at a provincial hospital in the Tshwane region, South Africa. Attitudes of staff on pre-identified staff satisfaction variables were assessed. These variables were employed to implement an internal marketing strategy. A list of variables was formulated after an extensive literature study had been conducted. A total of 416 staff members voluntarily completed a self-administered questionnaire. A five-point Likert type scale was used to measure the levels of satisfaction on staff-related issues, with a view to addressing issues in the internal marketing strategy. Findings : It was evident that the management principles currently employed by the management team were a cause for concern among staff members. Based on the analysis that identified the satisfaction variables best it was clear that management should take immediate steps to address the following issues : • Clarification of hospital goals \\ objectives; • Understanding the goals of the respective departments; • The functioning of the Human resource department; • Functioning of the overall hospital management; and Implications: This paper

  13. Evaluation of point-of-care tests for detecting microalbuminuria in ...

    African Journals Online (AJOL)

    Evaluation of point-of-care tests for detecting microalbuminuria in diabetic patients. ... creatinine (modified Jaffe) and albumin-to-creatinine ratio (ACR). Results: Linear regression analysis demonstrated a good correlation for the HemoCue® ...

  14. Point-of-care estimation of haemoglobin concentration in all age ...

    African Journals Online (AJOL)

    Point-of-care estimation of haemoglobin concentration in all age groups in clinical ... and the results were compared using standard scatter and difference plots. ... Hb measurements with a smaller sample volume, improved turnaround time, ...

  15. Increased health care utilisation in international adoptees

    DEFF Research Database (Denmark)

    Graff, Heidi Jeannet; Siersma, Volkert Dirk; Kragstrup, Jakob

    2015-01-01

    comprised internationallyadopted children (n = 6,820), adopted between 1994 and2005, and all non-adopted children (n = 492,374) who couldbe matched with the adopted children on sex, age, municipalityand family constellation at the time of adoption. Results: International adoption increased the use......Introduction: Several studies have documented thatinternational adoptees have an increased occurrence ofhealth problems and contacts to the health-care systemafter arriving to their new country of residence. This maybe explained by pre-adoption adversities, especially for theperiod immediately...... after adoption. Our study aimed to theassess health-care utilisation of international adoptees inprimary and secondary care for somatic and psychiatricdiagnoses in a late post-adoption period. Is there an increaseduse of the health-care system in this period, evenwhen increased morbidity in the group...

  16. Current and Potential Developments of Cortisol Aptasensing towards Point-of-Care Diagnostics (POTC

    Directory of Open Access Journals (Sweden)

    Azrul Syafiq Zainol Abidin

    2017-05-01

    Full Text Available Anxiety is a psychological problem that often emerges during the normal course of human life. The detection of anxiety often involves a physical exam and a self-reporting questionnaire. However, these approaches have limitations, as the data might lack reliability and consistency upon application to the same population over time. Furthermore, there might be varying understanding and interpretations of the particular question by the participant, which necessitating the approach of using biomarker-based measurement for stress diagnosis. The most prominent biomarker related to stress, hormone cortisol, plays a key role in the fight-or-flight situation, alters the immune response, and suppresses the digestive and the reproductive systems. We have taken the endeavour to review the available aptamer-based biosensor (aptasensor for cortisol detection. The potential point-of-care diagnostic strategies that could be harnessed for the aptasensing of cortisol were also envisaged.

  17. Group vector space method for estimating enthalpy of vaporization of organic compounds at the normal boiling point.

    Science.gov (United States)

    Wenying, Wei; Jinyu, Han; Wen, Xu

    2004-01-01

    The specific position of a group in the molecule has been considered, and a group vector space method for estimating enthalpy of vaporization at the normal boiling point of organic compounds has been developed. Expression for enthalpy of vaporization Delta(vap)H(T(b)) has been established and numerical values of relative group parameters obtained. The average percent deviation of estimation of Delta(vap)H(T(b)) is 1.16, which show that the present method demonstrates significant improvement in applicability to predict the enthalpy of vaporization at the normal boiling point, compared the conventional group methods.

  18. Ten key points for the appropriate use of antibiotics in hospitalised patients: a consensus from the Antimicrobial Stewardship and Resistance Working Groups of the International Society of Chemotherapy

    NARCIS (Netherlands)

    Hara, G. Levy; Kanj, S.S.; Pagani, L.; Abbo, L.; Endimiani, A.; Wertheim, H.F.L.; Amabile-Cuevas, C.; Tattevin, P.; Mehtar, S.; Cardoso, F.; Unal, S.; Gould, I.

    2016-01-01

    The Antibiotic Stewardship and Resistance Working Groups of the International Society for Chemotherapy propose ten key points for the appropriate use of antibiotics in hospital settings. (i) Get appropriate microbiological samples before antibiotic administration and carefully interpret the results:

  19. Economic Evidence and Point-of-Care Testing

    Science.gov (United States)

    St John, Andrew; Price, Christopher P

    2013-01-01

    Health economics has been an established feature of the research, policymaking, practice and management in the delivery of healthcare. However its role is increasing as the cost of healthcare begins to drive changes in most healthcare systems. Thus the output from cost effectiveness studies is now being taken into account when making reimbursement decisions, e.g. in Australia and the United Kingdom. Against this background it is also recognised that the health economic tools employed in healthcare, and particularly the output from the use of these tools however, are not always employed in the routine delivery of services. One of the notable consequences of this situation is the poor record of innovation in healthcare with respect to the adoption of new technologies, and the realisation of their benefits. The evidence base for the effectiveness of diagnostic services is well known to be limited, and one consequence of this has been a very limited literature on cost effectiveness. One reason for this situation is undoubtedly the reimbursement strategies employed in laboratory medicine for many years, simplistically based on the complexity of the test procedure, and the delivery as a cost-per-test service. This has proved a disincentive to generate the required evidence, and little effort to generate an integrated investment and disinvestment business case, associated with care pathway changes. Point-of-care testing creates a particularly challenging scenario because, on the one hand, the unit cost-per-test is larger through the loss of the economy of scale offered by automation, whilst it offers the potential of substantial savings through enabling rapid delivery of results, and reduction of facility costs. This is important when many health systems are planning for complete system redesign. We review the literature on economic assessment of point-of-care testing in the context of these developments. PMID:24151342

  20. Pediatric Lung Abscess: Immediate Diagnosis by Point-of-Care Ultrasound.

    Science.gov (United States)

    Kraft, Clara; Lasure, Benjamin; Sharon, Melinda; Patel, Paulina; Minardi, Joseph

    2018-06-01

    The diagnosis of lung abscess can be difficult to make and often requires imaging beyond plain chest x-ray. The decision to further image with computed tomography should be weighed against the risks of radiation exposure, especially in pediatric patients. In addition, the cost and potential impact on length of stay from obtaining computed tomography scans should be considered. In this report, we describe a case of lung abscess made immediately using point-of-care ultrasound in the emergency department. To our knowledge, there are no previous cases describing lung abscess diagnosed by point-of-care ultrasound. This case report aims to describe a case of pediatric lung abscess, review the ultrasound findings, and discuss relevant literature on the topic.

  1. Normalization method for metabolomics data using optimal selection of multiple internal standards

    Directory of Open Access Journals (Sweden)

    Yetukuri Laxman

    2007-03-01

    Full Text Available Abstract Background Success of metabolomics as the phenotyping platform largely depends on its ability to detect various sources of biological variability. Removal of platform-specific sources of variability such as systematic error is therefore one of the foremost priorities in data preprocessing. However, chemical diversity of molecular species included in typical metabolic profiling experiments leads to different responses to variations in experimental conditions, making normalization a very demanding task. Results With the aim to remove unwanted systematic variation, we present an approach that utilizes variability information from multiple internal standard compounds to find optimal normalization factor for each individual molecular species detected by metabolomics approach (NOMIS. We demonstrate the method on mouse liver lipidomic profiles using Ultra Performance Liquid Chromatography coupled to high resolution mass spectrometry, and compare its performance to two commonly utilized normalization methods: normalization by l2 norm and by retention time region specific standard compound profiles. The NOMIS method proved superior in its ability to reduce the effect of systematic error across the full spectrum of metabolite peaks. We also demonstrate that the method can be used to select best combinations of standard compounds for normalization. Conclusion Depending on experiment design and biological matrix, the NOMIS method is applicable either as a one-step normalization method or as a two-step method where the normalization parameters, influenced by variabilities of internal standard compounds and their correlation to metabolites, are first calculated from a study conducted in repeatability conditions. The method can also be used in analytical development of metabolomics methods by helping to select best combinations of standard compounds for a particular biological matrix and analytical platform.

  2. Monitoring of international normalized ratios: comparison of community nurses with family physicians.

    Science.gov (United States)

    Levine, Max A; Shao, Wei; Klein, Douglas

    2012-08-01

    To determine whether community-based, nurse-led monitoring of the international normalized ratio (INR) in patients requiring long-term warfarin therapy was comparable to traditional physician monitoring. A retrospective cohort analysis of patients taking long-term warfarin therapy. The study used data gathered from 3 family medicine clinics in a primary care network in Edmonton, Alta. Medical records of patients currently taking warfarin were examined. Implementation of nurse-led monitoring in a primary care network in place of standard family physician INR monitoring. The degree of INR control before and after the implementation of nurse-run INR monitoring was assessed. The average proportion of time spent outside of therapeutic INR ranges, as well as the average number of days between successive INR readings, was calculated and compared. The degree of control placed patients into either a good-control group (out of range ≤ 25% of the time) or a moderate-control group (out of range > 25% of the time) and these groups were compared. Before nurse monitoring, INR values were out of range 20.4% of the time; after nurse monitoring they were out of range 19.2% of the time (P = .115); the time between sequential INR readings also did not differ before and after implementation of nurse monitoring (23.9 vs 21.6 days, P = .789). Nurse-led monitoring of INR is as effective as traditional physician monitoring. Advantages of nurse-led monitoring might include freeing family physicians to see more patients or to spend less time at work. It might also represent potential cost savings.

  3. Health information needs of professional nurses required at the point of care

    Directory of Open Access Journals (Sweden)

    Esmeralda Ricks

    2015-06-01

    Conclusion: This study has enabled the researcher to identify the information needs required by professional nurses at the point of care to enhance the delivery of patient care. The research results were used to develop a mobile library that could be accessed by professional nurses.

  4. Performance of 4 Point-of-Care Screening Tests for Feline Leukemia Virus and Feline Immunodeficiency Virus.

    Science.gov (United States)

    Levy, J K; Crawford, P Cynda; Tucker, S J

    2017-03-01

    More than 3 million cats in the United States are infected with FeLV or FIV. The cornerstone of control is identification and segregation of infected cats. To compare test performance with well-characterized clinical samples of currently available FeLV antigen/FIV antibody combination test kits. Surplus serum and plasma from diagnostic samples submitted by animal shelters, diagnostic laboratories, veterinary clinics, and cat research colonies. None of the cats had been vaccinated against FIV. The final sample set included 146 FeLV+, 154 FeLV-, 94 FIV+, and 97 FIV- samples. Prospective, blind comparison to a gold standard: Samples were evaluated in 4 different point-of-care tests by ELISA antigen plate tests (FeLV) and virus isolation (FIV) as the reference standards. All test results were visually read by 2 blinded observers. Sensitivity and specificity, respectively, for FeLV were SNAP ® (100%/100%), WITNESS ® (89.0%/95.5%), Anigen ® (91.8%/95.5%), and VetScan ® (85.6%/85.7%). Sensitivity and specificity for FIV were SNAP ® (97.9%/99.0%), WITNESS ® (94.7%/100%), Anigen ® (96.8%/99.0%), and VetScan ® (91.5%/99.0%). The SNAP ® test had the best performance for FeLV, but there were no significant differences for FIV. In typical cat populations with seroprevalence of 1-5%, a majority of positive results reported by most point-of-care test devices would be false-positives. This could result in unnecessary segregation or even euthanasia. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. Early Innovative Immersion: A Course for Pre-Medical Professions Students Using Point-of-Care Ultrasound.

    Science.gov (United States)

    Smalley, Courtney M; Browne, Vaughn; Kaplan, Bonnie; Russ, Brian; Wilson, Juliana; Lewiss, Resa E

    2016-12-01

    In preparing for medical school admissions, premedical students seek opportunities to expand their medical knowledge. Knowing what students seek and what point-of-care ultrasound offers, we created a novel educational experience using point-of-care ultrasound. The innovation has 3 goals: (1) to use point-of-care ultrasound to highlight educational concepts such as the flipped classroom, simulation, hands-on interaction, and medical exposure; (2) to work collaboratively with peers; and (3) to expose premedical students to mentoring for the medical school application process. We believe that this course could be used to encourage immersive innovation with point-of-care ultrasound, progressive education concepts, and preparation for medical admissions. © 2016 by the American Institute of Ultrasound in Medicine.

  6. Hematological clozapine monitoring with a point-of-care device

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Thode, Dorrit; Stenager, Elsebeth

    2012-01-01

    for several reasons, perhaps most importantly because of the mandatory hematological monitoring. The Chempaq Express Blood Counter (Chempaq XBC) is a point-of-care device providing counts of white blood cells (WBC) and granulocytes based on a capillary blood sampling. A randomized cross-over trial design...

  7. Point-of-care testing: applications of 3D printing.

    Science.gov (United States)

    Chan, Ho Nam; Tan, Ming Jun Andrew; Wu, Hongkai

    2017-08-08

    Point-of-care testing (POCT) devices fulfil a critical need in the modern healthcare ecosystem, enabling the decentralized delivery of imperative clinical strategies in both developed and developing worlds. To achieve diagnostic utility and clinical impact, POCT technologies are immensely dependent on effective translation from academic laboratories out to real-world deployment. However, the current research and development pipeline is highly bottlenecked owing to multiple restraints in material, cost, and complexity of conventionally available fabrication techniques. Recently, 3D printing technology has emerged as a revolutionary, industry-compatible method enabling cost-effective, facile, and rapid manufacturing of objects. This has allowed iterative design-build-test cycles of various things, from microfluidic chips to smartphone interfaces, that are geared towards point-of-care applications. In this review, we focus on highlighting recent works that exploit 3D printing in developing POCT devices, underscoring its utility in all analytical steps. Moreover, we also discuss key advantages of adopting 3D printing in the device development pipeline and identify promising opportunities in 3D printing technology that can benefit global health applications.

  8. Point-of-care blood eosinophil count in a severe asthma clinic setting.

    Science.gov (United States)

    Heffler, Enrico; Terranova, Giovanni; Chessari, Carlo; Frazzetto, Valentina; Crimi, Claudia; Fichera, Silvia; Picardi, Giuseppe; Nicolosi, Giuliana; Porto, Morena; Intravaia, Rossella; Crimi, Nunzio

    2017-07-01

    One of the main severe asthma phenotypes is severe eosinophilic or eosinophilic refractory asthma for which novel biologic agents are emerging as therapeutic options. In this context, blood eosinophil counts are one of the most reliable biomarkers. To evaluate the performance of a point-of-care peripheral blood counter in a patients with severe asthma. The blood eosinophil counts of 76 patients with severe asthma were evaluated by point-of-care and standard analyzers. A significant correlation between blood eosinophils assessed by the 2 devices was found (R 2  = 0.854, P asthma and the ELEN index, a composite score useful to predict sputum eosinophilia. The results of our study contribute to the validation of a point-of-care device to assess blood eosinophils and open the possibility of using this device for the management of severe asthma management. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  9. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    Science.gov (United States)

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  10. Business models & business cases for point-of-care testing

    NARCIS (Netherlands)

    Staring, A.J.; Meertens, L. O.; Sikkel, N.

    2016-01-01

    Point-Of-Care Testing (POCT) enables clinical tests at or near the patient, with test results that are available instantly or in a very short time frame, to assist caregivers with immediate diagnosis and/or clinical intervention. The goal of POCT is to provide accurate, reliable, fast, and

  11. The strength of primary care in Europe : an international comparative study

    NARCIS (Netherlands)

    Kringos, D.S.; Boerma, W.G.W.; Bourgueil, Y.; Cartier, T.; Dedeu, T.; Hasvold, T.; Groenewegen, P.P.; et al, [No Value

    2013-01-01

    Background A suitable definition of primary care to capture the variety of prevailing international organisation and service-delivery models is lacking. Aim Evaluation of strength of primary care in Europe. Design and setting International comparative cross-sectional study performed in 2009–2010,

  12. The strength of primary care in Europe: an international comparative study

    NARCIS (Netherlands)

    Kringos, Dionne; Boerma, Wienke; Bourgueil, Yann; Cartier, Thomas; Dedeu, Toni; Hasvold, Toralf; Hutchinson, Allen; Lember, Margus; Oleszczyk, Marek; Rotar Pavlic, Danica; Svab, Igor; Tedeschi, Paolo; Wilm, Stefan; Wilson, Andrew; Windak, Adam; van der Zee, Jouke; Groenewegen, Peter

    2013-01-01

    A suitable definition of primary care to capture the variety of prevailing international organisation and service-delivery models is lacking. Evaluation of strength of primary care in Europe. International comparative cross-sectional study performed in 2009-2010, involving 27 EU member states, plus

  13. Point-of-Care Ultrasound for Pulmonary Concerns in Remote Spaceflight Triage Environments.

    Science.gov (United States)

    Johansen, Benjamin D; Blue, Rebecca S; Castleberry, Tarah L; Antonsen, Erik L; Vanderploeg, James M

    2018-02-01

    With the development of the commercial space industry, growing numbers of spaceflight participants will engage in activities with a risk for pulmonary injuries, including pneumothorax, ebullism, and decompression sickness, as well as other concomitant trauma. Medical triage capabilities for mishaps involving pulmonary conditions have not been systematically reviewed. Recent studies have advocated the use of point-of-care ultrasound to screen for lung injury or illness. The operational utility of portable ultrasound systems in disaster relief and other austere settings may be relevant to commercial spaceflight. A systematic review of published literature was conducted concerning the use of point-of-care pulmonary ultrasound techniques in austere environments, including suggested examination protocols for triage and diagnosis. Recent studies support the utility of pulmonary ultrasound examinations when performed by skilled operators, and comparability of the results to computed tomography and chest radiography for certain conditions, with important implications for trauma management in austere environments. Pulmonary injury and illness are among the potential health risks facing spaceflight participants. Implementation of point-of-care ultrasound protocols could aid in the rapid diagnosis, triage, and treatment of such conditions. Though operator-dependent, ultrasound, with proper training, experience, and equipment, could be a valuable tool in the hands of a first responder supporting remote spaceflight operations.Johansen BD, Blue RS, Castleberry TL, Antonsen EL, Vanderploeg JM. Point-of-care ultrasound for pulmonary concerns in remote spaceflight triage environments. Aerosp Med Hum Perform. 2018; 89(2):122-129.

  14. Microchip capillary electrophoresis for point-of-care analysis of lithium

    NARCIS (Netherlands)

    Vrouwe, E.X.; Luttge, R.; Vermes, I.; Berg, van den A.

    2007-01-01

    Background: Microchip capillary electrophoresis (CE) is a promising method for chemical analysis of complex samples such as whole blood. We evaluated the method for point-of-care testing of lithium. Methods: Chemical separation was performed on standard glass microchip CE devices with a conductivity

  15. Biomarkers as point-of-care tests to guide prescription of antibiotics in patients with acute respiratory infections in primary care.

    Science.gov (United States)

    Aabenhus, Rune; Jensen, Jens-Ulrik S; Jørgensen, Karsten Juhl; Hróbjartsson, Asbjørn; Bjerrum, Lars

    2014-11-06

    Background Acute respiratory infections (ARIs) are by far the most common reason for prescribing an antibiotic in primary care, even though the majority of ARIs are of viral or non-severe bacterial aetiology. Unnecessary antibiotic use will, in many cases, not be beneficial to the patients' recovery and expose them to potential side effects. Furthermore, as a causal link exists between antibiotic use and antibiotic resistance, reducing unnecessary antibiotic use is a key factor in controlling this important problem. Antibiotic resistance puts increasing burdens on healthcare services and renders patients at risk of future ineffective treatments, in turn increasing morbidity and mortality from infectious diseases. One strategy aiming to reduce antibiotic use in primary care is the guidance of antibiotic treatment by use of a point-of-care biomarker. A point-of-care biomarker of infection forms part of the acute phase response to acute tissue injury regardless of the aetiology (infection, trauma and inflammation) and may in the correct clinical context be used as a surrogate marker of infection,possibly assisting the doctor in the clinical management of ARIs.Objectives To assess the benefits and harms of point-of-care biomarker tests of infection to guide antibiotic treatment in patients presenting with symptoms of acute respiratory infections in primary care settings regardless of age.Search methods We searched CENTRAL (2013, Issue 12), MEDLINE (1946 to January 2014), EMBASE (2010 to January 2014), CINAHL (1981 to January 2014), Web of Science (1955 to January 2014) and LILACS (1982 to January 2014).Selection criteria We included randomised controlled trials (RCTs) in primary care patients with ARIs that compared use of point-of-care biomarkers with standard of care. We included trials that randomised individual patients as well as trials that randomised clusters of patients(cluster-RCTs).Two review authors independently extracted data on the following outcomes: i

  16. Health information needs of professional nurses required at the point of care.

    Science.gov (United States)

    Ricks, Esmeralda; ten Ham, Wilma

    2015-06-11

    Professional nurses work in dynamic environments and need to keep up to date with relevant information for practice in nursing to render quality patient care. Keeping up to date with current information is often challenging because of heavy workload, diverse information needs and the accessibility of the required information at the point of care. The aim of the study was to explore and describe the information needs of professional nurses at the point of care in order to make recommendations to stakeholders to develop a mobile library accessible by means of smart phones when needed. The researcher utilised a quantitative, descriptive survey design to conduct this study. The target population comprised 757 professional nurses employed at a state hospital. Simple random sampling was used to select a sample of the wards, units and departments for inclusion in the study. A convenience sample of 250 participants was selected. Two hundred and fifty structured self-administered questionnaires were distributed amongst the participants. Descriptive statistics were used to analyse the data. A total of 136 completed questionnaires were returned. The findings highlighted the types and accessible sources of information. Information needs of professional nurses were identified such as: extremely drug-resistant tuberculosis, multi-drug-resistant tuberculosis, HIV, antiretrovirals and all chronic lifestyle diseases. This study has enabled the researcher to identify the information needs required by professional nurses at the point of care to enhance the delivery of patient care. The research results were used to develop a mobile library that could be accessed by professional nurses.

  17. Performance indicators related to points scoring and winning in international rugby sevens.

    Science.gov (United States)

    Higham, Dean G; Hopkins, Will G; Pyne, David B; Anson, Judith M

    2014-05-01

    Identification of performance indicators related to scoring points and winning is needed to inform tactical approaches to international rugby sevens competition. The aim of this study was to characterize team performance indicators in international rugby sevens and quantify their relationship with a team's points scored and probability of winning. Performance indicators of each team during 196 matches of the 2011/2012 International Rugby Board Sevens World Series were modeled for their linear relationships with points scored and likelihood of winning within (changes in team values from match to match) and between (differences between team values averaged over all matches) teams. Relationships were evaluated as the change and difference in points and probability of winning associated with a two within- and between-team standard deviations increase in performance indicator values. Inferences about relationships were assessed using a smallest meaningful difference of one point and a 10% probability of a team changing the outcome of a close match. All indicators exhibited high within-team match-to-match variability (intraclass correlation coefficients ranged from 0.00 to 0.23). Excluding indicators representing points-scoring actions or events occurring on average less than once per match, 13 of 17 indicators had substantial clear within-team relationships with points scored and/or likelihood of victory. Relationships between teams were generally similar in magnitude but unclear. Tactics that increase points scoring and likelihood of winning should be based on greater ball possession, fewer rucks, mauls, turnovers, penalties and free kicks, and limited passing. Key pointsSuccessful international rugby sevens teams tend to maintain ball possession; more frequently avoid taking the ball into contact; concede fewer turnovers, penalties and free kicks; retain possession in scrums, rucks and mauls; and limit passing the ball.Selected performance indicators may be used to

  18. Creating a Meeting Point of Understanding: Interpreters' Experiences in Swedish Childhood Cancer Care.

    Science.gov (United States)

    Granhagen Jungner, Johanna; Tiselius, Elisabet; Lützén, Kim; Blomgren, Klas; Pergert, Pernilla

    2016-01-01

    Children and families with a foreign background and limited Swedish proficiency have to communicate through interpreters in childhood cancer care centers in Sweden. Interpreter-mediated events deal with many difficulties that potentially hinder the transfer of information. The purpose of our study was to explore interpreters' experiences of interpreting between health care staff and limited Swedish proficiency patients/families in childhood cancer care. Using purposive samples, we interviewed 11 interpreters individually. The interviews were analyzed using qualitative content analysis. Analyses of the data resulted in the main theme of creating a meeting point of understanding, constructed from 3 subthemes: balancing between cultures, bridging the gaps of knowledge, and balancing between compassion and professionalism. Our result shows that in order to create a sustainable meeting point of understanding, it is necessary to explain both the context and cultural differences. These results suggest that the responsibility for information transfer lies with both the health care profession and the interpreters. Tools have to be developed for both parties to contribute to creating the meeting point of understanding. © 2015 by Association of Pediatric Hematology/Oncology Nurses.

  19. A centrifugal microfluidic platform for point-of-care diagnostic applications

    CSIR Research Space (South Africa)

    Hugo, S

    2014-02-01

    Full Text Available Microfluidic systems enable precise control over tiny volumes of fluid in a compact and low-cost form, thus providing the ideal platform on which to develop point-of-care diagnostic solutions. Centrifugal microfluidic systems, also referred...

  20. Near Point of Convergence Break for Different Age Groups in Turkish Population with Normal Binocular Vision: Normative Data

    Directory of Open Access Journals (Sweden)

    Nihat Sayın

    2013-12-01

    Full Text Available Purpose: The purpose of this study was to evaluate the near point of convergence break in Turkish population with normal binocular vision and to obtain the normative data for the near point of convergence break in different age groups. Such database has not been previously reported. Material and Method: In this prospective study, 329 subjects with normal binocular vision (age range, 3-72 years were evaluated. The near point of convergence break was measured 4 times repeatedly with an accommodative target. Mean values of near point of convergence break were provided for these age groups (≤10, 11-20, 21-30, 31-40, 41-50, 51-60, and >60 years old. A statistical comparison (one-way ANOVA and post-hoc test of these values between age groups was performed. A correlation between the near point of convergence break and age was evaluated by Pearson’s correlation test. Results: The mean value for near point of convergence break was 2.46±1.88 (0.5-14 cm. Specifically, 95% of measurements in all subjects were 60 year-old age groups in the near point of convergence break values (p=0.0001, p=0.0001, p=0.006, p=0.001, p= 0.004. A mild positive correlation was observed between the increase in near point of convergence break and increase of age (r=0.355 (p<0.001. Discussion: The values derived from a relatively large study population to establish a normative database for the near point of convergence break in the Turkish population with normal binocular vision are in relevance with age. This database has not been previously reported. (Turk J Ophthalmol 2013; 43: 402-6

  1. International normalized ratio self-testing and self-management: improving patient outcomes

    Directory of Open Access Journals (Sweden)

    Pozzi M

    2016-10-01

    Full Text Available Matteo Pozzi,1 Julia Mitchell,2 Anna Maria Henaine,3 Najib Hanna,4 Ola Safi,4 Roland Henaine2 1Department of Adult Cardiac Surgery, “Louis Pradel” Cardiologic Hospital, Lyon, France; 2Department of Congenital Cardiac Surgery, “Louis Pradel” Cardiologic Hospital, Lyon, France; 3Clinical Pharmacology Unit, Lebanese University, Beirut, Lebanon; 4Pediatric Unit, “Hotel Dieu de France” Hospital, Saint Joseph University, Beirut, Lebanon Abstract: Long term oral anti-coagulation with vitamin K antagonists is a risk factor of hemorrhagic or thromebomlic complications. Periodic laboratory testing of international normalized ratio (INR and a subsequent dose adjustment are therefore mandatory. The use of home testing devices to measure INR has been suggested as a potential way to improve the comfort and compliance of the patients and their families, the frequency of monitoring and, finally, the management and safety of long-term oral anticoagulation. In pediatric patients, increased doses to obtain and maintain the therapeutic target INR, more frequent adjustments and INR testing, multiple medication, inconstant nutritional intake, difficult venepunctures, and the need to go to the laboratory for testing (interruption of school and parents’ work attendance highlight those difficulties. After reviewing the most relevant published studies of self-testing and self-management of INR for adult patients and children on oral anticoagulation, it seems that these are valuable and effective strategies of INR control. Despite an unclear relationship between INR control and clinical effects, these self-strategies provide a better control of the anticoagulant effect, improve patients and their family quality of life, and are an appealing solution in term of cost-effectiveness. Structured education and knowledge evaluation by trained health care professionals is required for children, to be able to adjust their dose treatment safely and accurately. However

  2. Broadband integrated mid infrared light sources as enabling technology for point of care mid-infrared spectroscopy

    Science.gov (United States)

    2017-08-20

    AFRL-AFOSR-JP-TR-2017-0061 Broadband integrated mid-infrared light sources as enabling technology for point-of-care mid- infrared spectroscopy Alex...mid-infrared light sources as enabling technology for point-of-care mid-infrared spectroscopy 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER FA2386-16-1-4037...Broadband integrated mid-infrared light sources as enabling technology for point-of-care mid- infrared spectroscopy ” Date: 16th August 2017 Name

  3. Small copper fixed-point cells of the hybrid type to be used in place of normal larger cells

    Science.gov (United States)

    Battuello, M.; Girard, F.; Florio, M.

    2012-10-01

    Two small cells for the realization of the fixed point of copper were constructed and investigated at INRIM. They are of the same hybrid design generally adopted for the eutectic high-temperature fixed-point cells, namely a structure with a sacrificial graphite sleeve and a layer of flexible carbon-carbon composite sheet (C/C sheet). Because of the largely different design with respect to the cells normally adopted for the construction of pure metal fixed points, they were compared and characterized with respect to the normal cells used at INRIM for the ITS-90 realization. Two different furnaces were used to compare hybrid and normal cells. One of the hybrid cells was also used in different configurations, i.e. without the C/C sheet and with two layers of sheet. The cells were compared with different operative conditions, i.e. temperature settings of the furnaces for inducing the freeze, and repeatability and reproducibility were investigated. Freezing temperature and shape of the plateaux obtained under the different conditions were analysed. As expected the duration of the plateaux obtained with the hybrid cells is considerably shorter than with the normal cell, but this does not affect the results in terms of freezing temperature. Measurements with the modified cell showed that the use of a double C/C sheet may improve both repeatability and reproducibility of the plateaux.

  4. Small copper fixed-point cells of the hybrid type to be used in place of normal larger cells

    International Nuclear Information System (INIS)

    Battuello, M; Girard, F; Florio, M

    2012-01-01

    Two small cells for the realization of the fixed point of copper were constructed and investigated at INRIM. They are of the same hybrid design generally adopted for the eutectic high-temperature fixed-point cells, namely a structure with a sacrificial graphite sleeve and a layer of flexible carbon–carbon composite sheet (C/C sheet). Because of the largely different design with respect to the cells normally adopted for the construction of pure metal fixed points, they were compared and characterized with respect to the normal cells used at INRIM for the ITS-90 realization. Two different furnaces were used to compare hybrid and normal cells. One of the hybrid cells was also used in different configurations, i.e. without the C/C sheet and with two layers of sheet. The cells were compared with different operative conditions, i.e. temperature settings of the furnaces for inducing the freeze, and repeatability and reproducibility were investigated. Freezing temperature and shape of the plateaux obtained under the different conditions were analysed. As expected the duration of the plateaux obtained with the hybrid cells is considerably shorter than with the normal cell, but this does not affect the results in terms of freezing temperature. Measurements with the modified cell showed that the use of a double C/C sheet may improve both repeatability and reproducibility of the plateaux. (paper)

  5. International comparisons in critical care: a necessity and challenge.

    Science.gov (United States)

    Wunsch, Hannah; Rowan, Kathryn M; Angus, Derek C

    2007-12-01

    Understanding variation in critical care resources, and delivery of care between countries will allow for improved disaster planning, evaluation of research findings, and assessment of the utility of critical care itself. This review describes the available data for international comparisons and the many factors that need to be addressed for an appropriate interpretation of results. Recent studies on subgroups of critical care patients include data from many different countries. These new studies provide important information on the overall incidence of these disease states, but most of these international studies do not take into account the critical care resources of the countries being discussed. For an appropriate interpretation of findings the relevant baseline critical care resources, prevalence of diseases, and cultural practices, need to be quantified. The existence of these other factors prevents the use of a severity of illness scoring system alone to account for differences between countries. Many recent critical care studies include data from multiple countries. With continued movement towards international studies, and improvements in data collection systems, comparisons between countries are becoming easier. These findings need to be interpreted in the context of all the relevant country information.

  6. Microfluidic cartridges for automated, point-of-care blood cell counting

    CSIR Research Space (South Africa)

    Smith, Suzanne

    2016-11-01

    Full Text Available Disposable, low-cost microfluidic cartridges for automated blood cell counting applications are presented in this article. The need for point-of-care medical diagnostic tools is evident, particularly in low-resource and rural settings, and a full...

  7. Correlation between the solubility of aromatic hydrocarbons in water and micellar solutions, with their normal boiling points

    International Nuclear Information System (INIS)

    Almgren, M.; Grieser, F.; Powell, J.R.; Thomas, J.K.

    1979-01-01

    A linear correlation between the logarithm of the solubility in water of aromatic hydrocarbons and their normal boiling points is shown. Similarly, the logarithm of the distribution ratio of aromatic hydrocarbons in aqueous micellar solution is shown to be linearly related to the boiling points of the hydrocarbons. 2 figures, 2 tables

  8. Internal marketing: creating quality employee experiences in health care organizations.

    Science.gov (United States)

    Masri, Maysoun Dimachkie; Oetjen, Dawn; Rotarius, Timothy

    2011-01-01

    To cope with the recent challenges within the health care industry, health care managers need to engage in the internal marketing of their various services. Internal marketing has been used as an effective management tool to increase employees' motivation, satisfaction, and productivity (J Mark Commun. 2010;16(5):325-344). Health care managers should understand that an intense focus on internal marketing factors will lead to a quality experience for employees that will ultimately have a positive effect on the patient experiences.

  9. Point-of-care lactate and creatinine analysis for sick obstetric ...

    African Journals Online (AJOL)

    2016-03-15

    Mar 15, 2016 ... may take up to three days via the main hospital laboratory. The aim of this ... for handling point-of-care clinical chemistry devices and the most suitable .... Creatinine test strips and quality control solutions were stored in the ...

  10. Point of care testing of phospholipase A2 group IIA for serological diagnosis of rheumatoid arthritis

    Science.gov (United States)

    Liu, Nathan J.; Chapman, Robert; Lin, Yiyang; Mmesi, Jonas; Bentham, Andrew; Tyreman, Matthew; Abraham, Sonya; Stevens, Molly M.

    2016-02-01

    Secretory phospholipase A2 group IIA (sPLA2-IIA) was examined as a point of care marker for determining disease activity in rheumatoid (RA) and psoriatic (PsA) arthritis. Serum concentration and activity of sPLA2-IIA were measured using in-house antibodies and a novel point of care lateral flow device assay in patients diagnosed with varying severities of RA (n = 30) and PsA (n = 25) and found to correlate strongly with C-reactive protein (CRP). Levels of all markers were elevated in patients with active RA over those with inactive RA as well as both active and inactive PsA, indicating that sPLA2-IIA can be used as an analogue to CRP for RA diagnosis at point of care.Secretory phospholipase A2 group IIA (sPLA2-IIA) was examined as a point of care marker for determining disease activity in rheumatoid (RA) and psoriatic (PsA) arthritis. Serum concentration and activity of sPLA2-IIA were measured using in-house antibodies and a novel point of care lateral flow device assay in patients diagnosed with varying severities of RA (n = 30) and PsA (n = 25) and found to correlate strongly with C-reactive protein (CRP). Levels of all markers were elevated in patients with active RA over those with inactive RA as well as both active and inactive PsA, indicating that sPLA2-IIA can be used as an analogue to CRP for RA diagnosis at point of care. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08423g

  11. Fast blood plasma separation device for point-of-care applications

    Czech Academy of Sciences Publication Activity Database

    Ďurč, P.; Foret, František; Kubáň, Petr

    2018-01-01

    Roč. 183, JUN (2018), s. 55-60 ISSN 0039-9140 Institutional support: RVO:68081715 Keywords : blood plasma separation * capillary electrophoresis * point of care analysis * methanol * metabolites Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 4.162, year: 2016

  12. Point-of-care ultrasound education for non-physician clinicians in a resource-limited emergency department.

    Science.gov (United States)

    Stolz, Lori A; Muruganandan, Krithika M; Bisanzo, Mark C; Sebikali, Mugisha J; Dreifuss, Bradley A; Hammerstedt, Heather S; Nelson, Sara W; Nayabale, Irene; Adhikari, Srikar; Shah, Sachita P

    2015-08-01

    To describe the outcomes and curriculum components of an educational programme to train non-physician clinicians working in a rural, Ugandan emergency department in the use of POC ultrasound. The use of point-of-care ultrasound was taught to emergency care providers through lectures, bedsides teaching and hands-on practical sessions. Lectures were tailored to care providers' knowledge base and available therapeutic means. Every ultrasound examination performed by these providers was recorded over 4.5 years. Findings of these examinations were categorised as positive, negative, indeterminate or procedural. Other radiologic studies ordered over this same time period were also recorded. A total of 22,639 patients were evaluated in the emergency department by emergency care providers, and 2185 point-of-care ultrasound examinations were performed on 1886 patients. Most commonly used were the focused assessment with sonography in trauma examination (53.3%) and echocardiography (16.4%). Point-of-care ultrasound studies were performed more frequently than radiology department-performed studies. Positive findings were documented in 46% of all examinations. We describe a novel curriculum for point-of-care ultrasound education of non-physician emergency practitioners in a resource-limited setting. These non-physician clinicians integrated ultrasound into clinical practice and utilised this imaging modality more frequently than traditional radiology department imaging with a large proportion of positive findings. © 2015 John Wiley & Sons Ltd.

  13. ICG: a wiki-driven knowledgebase of internal control genes for RT-qPCR normalization.

    Science.gov (United States)

    Sang, Jian; Wang, Zhennan; Li, Man; Cao, Jiabao; Niu, Guangyi; Xia, Lin; Zou, Dong; Wang, Fan; Xu, Xingjian; Han, Xiaojiao; Fan, Jinqi; Yang, Ye; Zuo, Wanzhu; Zhang, Yang; Zhao, Wenming; Bao, Yiming; Xiao, Jingfa; Hu, Songnian; Hao, Lili; Zhang, Zhang

    2018-01-04

    Real-time quantitative PCR (RT-qPCR) has become a widely used method for accurate expression profiling of targeted mRNA and ncRNA. Selection of appropriate internal control genes for RT-qPCR normalization is an elementary prerequisite for reliable expression measurement. Here, we present ICG (http://icg.big.ac.cn), a wiki-driven knowledgebase for community curation of experimentally validated internal control genes as well as their associated experimental conditions. Unlike extant related databases that focus on qPCR primers in model organisms (mainly human and mouse), ICG features harnessing collective intelligence in community integration of internal control genes for a variety of species. Specifically, it integrates a comprehensive collection of more than 750 internal control genes for 73 animals, 115 plants, 12 fungi and 9 bacteria, and incorporates detailed information on recommended application scenarios corresponding to specific experimental conditions, which, collectively, are of great help for researchers to adopt appropriate internal control genes for their own experiments. Taken together, ICG serves as a publicly editable and open-content encyclopaedia of internal control genes and accordingly bears broad utility for reliable RT-qPCR normalization and gene expression characterization in both model and non-model organisms. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  14. Practical challenges related to point of care testing

    Directory of Open Access Journals (Sweden)

    Julie L.V. Shaw

    2016-04-01

    Full Text Available Point of care testing (POCT refers to laboratory testing that occurs near to the patient, often at the patient bedside. POCT can be advantageous in situations requiring rapid turnaround time of test results for clinical decision making. There are many challenges associated with POCT, mainly related to quality assurance. POCT is performed by clinical staff rather than laboratory trained individuals which can lead to errors resulting from a lack of understanding of the importance of quality control and quality assurance practices. POCT is usually more expensive than testing performed in the central laboratory and requires a significant amount of support from the laboratory to ensure the quality testing and meet accreditation requirements.Here, specific challenges related to POCT compliance with accreditation standards are discussed along with strategies that can be used to overcome these challenges. These areas include: documentation of POCT orders, charting of POCT results as well as training and certification of individuals performing POCT. Factors to consider when implementing connectivity between POCT instruments and the electronic medical record are also discussed in detail and include: uni-directional versus bidirectional communication, linking patient demographic information with POCT software, the importance of positive patient identification and considering where to chart POCT results in the electronic medical record. Keywords: Point of care Testing, Laboratory accreditation, Medical directive, Results documentation, Electronic Medical Record, Transcription error, Connectivity, Positive patient identification

  15. Preparing for the primary care clinic: an ambulatory boot camp for internal medicine interns

    Science.gov (United States)

    Esch, Lindsay M.; Bird, Amber-Nicole; Oyler, Julie L.; Lee, Wei Wei; Shah, Sachin D.; Pincavage, Amber T.

    2015-01-01

    Introduction Internal medicine (IM) interns start continuity clinic with variable ambulatory training. Multiple other specialties have utilized a boot camp style curriculum to improve surgical and procedural skills, but boot camps have not been used to improve interns’ ambulatory knowledge and confidence. The authors implemented and assessed the impact of an intern ambulatory boot camp pilot on primary care knowledge, confidence, and curricular satisfaction. Methods During July 2014, IM interns attended ambulatory boot camp. It included clinically focused case-based didactic sessions on common ambulatory topics as well as orientation to the clinic and electronic medical records. Interns anonymously completed a 15-question pre-test on topics covered in the boot camp as well as an identical post-test after the boot camp. The interns were surveyed regarding their confidence and satisfaction. Results Thirty-eight interns participated in the boot camp. Prior to the boot camp, few interns reported confidence managing common outpatient conditions. The average pre-test knowledge score was 46.3%. The average post-test knowledge score significantly improved to 76.1% (pinterns reported that the boot camp was good preparation for clinics and 97% felt that the boot camp boosted their confidence. Conclusions The ambulatory boot camp pilot improved primary care knowledge, and interns thought it was good preparation for clinic. The ambulatory boot camp was well received and may be an effective way to improve the preparation of interns for primary care clinic. Further assessment of clinical performance and expansion to other programs and specialties should be considered. PMID:26609962

  16. Publication point indicators

    DEFF Research Database (Denmark)

    Elleby, Anita; Ingwersen, Peter

    2010-01-01

    ; the Cumulated Publication Point Indicator (CPPI), which graphically illustrates the cumulated gain of obtained vs. ideal points, both seen as vectors; and the normalized Cumulated Publication Point Index (nCPPI) that represents the cumulated gain of publication success as index values, either graphically......The paper presents comparative analyses of two publication point systems, The Norwegian and the in-house system from the interdisciplinary Danish Institute of International Studies (DIIS), used as case in the study for publications published 2006, and compares central citation-based indicators...... with novel publication point indicators (PPIs) that are formalized and exemplified. Two diachronic citation windows are applied: 2006-07 and 2006-08. Web of Science (WoS) as well as Google Scholar (GS) are applied to observe the cite delay and citedness for the different document types published by DIIS...

  17. Recombinant human G6PD for quality control and quality assurance of novel point-of-care diagnostics for G6PD deficiency.

    Directory of Open Access Journals (Sweden)

    Maria Kahn

    Full Text Available A large gap for the support of point-of-care testing is the availability of reagents to support quality control (QC of diagnostic assays along the supply chain from the manufacturer to the end user. While reagents and systems exist to support QC of laboratory screening tests for glucose-6-phosphate dehydrogenase (G6PD deficiency, they are not configured appropriately to support point-of-care testing. The feasibility of using lyophilized recombinant human G6PD as a QC reagent in novel point-of-care tests for G6PD deficiency is demonstrated.Human recombinant G6PD (r-G6PD was expressed in Escherichia coli and purified. Aliquots were stored at -80°C. Prior to lyophilization, aliquots were thawed, and three concentrations of r-G6PD (representing normal, intermediate, and deficient clinical G6PD levels were prepared and mixed with a protective formulation, which protects the enzyme activity against degradation from denaturation during the lyophilization process. Following lyophilization, individual single-use tubes of lyophilized r-G6PD were placed in individual packs with desiccants and stored at five temperatures for one year. An enzyme assay for G6PD activity was used to ascertain the stability of r-G6PD activity while stored at different temperatures.Lyophilized r-G6PD is stable and can be used as a control indicator. Results presented here show that G6PD activity is stable for at least 365 days when stored at -80°C, 4°C, 30°C, and 45°C. When stored at 55°C, enzyme activity was found to be stable only through day 28.Lyophilized r-G6PD enzyme is stable and can be used as a control for point-of-care tests for G6PD deficiency.

  18. Microfluidic point-of-care diagnostics for resource-poor environments

    Science.gov (United States)

    Laksanasopin, Tassaneewan; Chin, Curtis D.; Moore, Hannah; Wang, Jennifer; Cheung, Yuk Kee; Sia, Samuel K.

    2009-05-01

    Point-of-care (POC) diagnostics have tremendous potential to improve human health in remote and resource-poor settings. However, the design criteria for diagnostic tests appropriate in settings with limited infrastructure are unique and challenging. Here we present a custom optical reader which quantifies silver absorbance from heterogeneous immunoassays. The reader is simple and low-cost and suited for POC diagnostics.

  19. Extended Gate Field-Effect Transistor Biosensors for Point-Of-Care Testing of Uric Acid.

    Science.gov (United States)

    Guan, Weihua; Reed, Mark A

    2017-01-01

    An enzyme-free redox potential sensor using off-chip extended-gate field effect transistor (EGFET) with a ferrocenyl-alkanethiol modified gold electrode has been used to quantify uric acid concentration in human serum and urine. Hexacyanoferrate (II) and (III) ions are used as redox reagent. The potentiometric sensor measures the interface potential on the ferrocene immobilized gold electrode, which is modulated by the redox reaction between uric acid and hexacyanoferrate ions. The device shows a near Nernstian response to uric acid and is highly specific to uric acid in human serum and urine. The interference that comes from glucose, bilirubin, ascorbic acid, and hemoglobin is negligible in the normal concentration range of these interferents. The sensor also exhibits excellent long term reliability and is regenerative. This extended gate field effect transistor based sensor is promising for point-of-care detection of uric acid due to the small size, low cost, and low sample volume consumption.

  20. Aspects of the Normalization of Managerial Accounting in Romania on a Microeconomic Level

    Directory of Open Access Journals (Sweden)

    Sorin BRICIU

    2011-03-01

    Full Text Available The article presents the general frame of the normalization of managerial accounting on a national level, following an incursion in its international normalization. The objectives of the normalization of managerial accounting in Romania are presented into detail, from the authors’ point of view, as well as the profile and attributions of the managerial accountant as a normalizer. The article ends with the authors’ conclusions related to the normalization of managerial accounting in Romania on a microeconomic level.

  1. Publicly available models to predict normal boiling point of organic compounds

    International Nuclear Information System (INIS)

    Oprisiu, Ioana; Marcou, Gilles; Horvath, Dragos; Brunel, Damien Bernard; Rivollet, Fabien; Varnek, Alexandre

    2013-01-01

    Quantitative structure–property models to predict the normal boiling point (T b ) of organic compounds were developed using non-linear ASNNs (associative neural networks) as well as multiple linear regression – ISIDA-MLR and SQS (stochastic QSAR sampler). Models were built on a diverse set of 2098 organic compounds with T b varying in the range of 185–491 K. In ISIDA-MLR and ASNN calculations, fragment descriptors were used, whereas fragment, FPTs (fuzzy pharmacophore triplets), and ChemAxon descriptors were employed in SQS models. Prediction quality of the models has been assessed in 5-fold cross validation. Obtained models were implemented in the on-line ISIDA predictor at (http://infochim.u-strasbg.fr/webserv/VSEngine.html)

  2. Sharp tooth induced sublingual hematoma in a patient with elevated international normalized ratio

    Directory of Open Access Journals (Sweden)

    John Baliah

    2015-01-01

    Full Text Available Sublingual hematoma secondary to anticoagulation is a rare fatal condition. Hemorrhagic complications of warfarin are well-known. This particular case is unique because the patient was on warfarin for the past 2 years but did not develop the sublingual hematoma. However, a trauma by an attrited sharp cusp triggered the episode of the sublingual hematoma in this patient. Being a medical emergency, patient was promptly hospitalized in cardiac care unit and managed by medical team. The patient was transfused with 2 units of fresh frozen plasma and warfarin was temporarily stopped for 4 days. Alternate day regimen of warfarin was started after 4 days, and international normalized ratio dropped to 3. In dental management, enameloplasty of the mandibular first molar tooth was done to prevent trauma and ulcer development in the floor of the mouth. The hematoma resolved, and no new hematoma formation was observed for a period of 6 months.

  3. High sensitivity point-of-care device for direct virus diagnostics

    DEFF Research Database (Denmark)

    Kiilerich-Pedersen, Katrine; Dapra, Johannes; Cherré, Solène

    2013-01-01

    Influenza infections are associated with high morbidity and mortality, carry the risk of pandemics, and pose a considerable economic burden worldwide. To improve the management of the illness, it is essential with accurate and fast point-of-care diagnostic tools for use in the field or at the pat...

  4. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control... Transmitter Control Internal Transmitter Control Systems § 90.473 Operation of internal transmitter control systems through licensed fixed control points. An internal transmitter control system may be operated...

  5. On the slow diffusion of Point of Care systems in Therapeutic Drug Monitoring

    Directory of Open Access Journals (Sweden)

    Barbara eSanavio

    2015-02-01

    Full Text Available Recent advancements in point-of-care technologies show great transformative promises for personalized preventative and predictive medicine. However, fields like therapeutic drug monitoring, that first allowed for personalized treatment of patient’ disease, still lag behind in the widespread application of point-of-care devices for monitoring of patients. Surprisingly, very few applications in commonly monitored drugs, such as anti-epileptics, are paving the way for a point of care (PoC approach to patient’ therapy monitoring, compared to other fields –like intensive care cardiac markers monitoring, glycemic controls in diabetes, or bench-top hematological parameters analysis at the local drug store. Such delay in the development of portable fast clinically effective drug monitoring devices is in our opinion due more to an inertial drag on the pervasiveness of these new devices into the clinical field than a lack of technical capability. At the same time, some very promising technologies failed in the clinical practice for inadequate understanding of the outcome parameters necessary for a relevant technological breakthrough that has superior clinical performance. We hope, by overviewing both therapeutic drug monitoring practice and its yet unmet needs and latest advancement in micro and nanotechnology applications to PoC clinical devices, to help bridging the two communities, the one exploiting analytical technologies and the one mastering the most advanced techniques, into translating existing and forthcoming technologies in effective devices.

  6. Nursing care update: Internal radiation therapy

    International Nuclear Information System (INIS)

    Lowdermilk, D.L.

    1990-01-01

    Internal radiation therapy has been used in treating gynecological cancers for over 100 years. A variety of radioactive sources are currently used alone and in combination with other cancer treatments. Nurses need to be able to provide safe, comprehensive care to patients receiving internal radiation therapy while using precautions to keep the risks of exposure to a minimum. This article discusses current trends and issues related to such treatment for gynecological cancers.20 references

  7. The Lewisian turning point and international migration: the case of Japan.

    Science.gov (United States)

    Watanabe, S

    1994-01-01

    "This article critically examines the Lewisian turning point [concerning the availability of unlimited manpower resources] in light of Japan's experience since the mid-1800s. Japan reached its Lewisian turning point around 1960. Contrary to the assumptions of the theory however, the findings for Japan indicate that political factors have been more determinative of the rate of migration than purely economic ones. Prior to its turning point in 1960, international relations, war and forced repatriation were the decisive factors. Recently, though the inflow of foreign workers to fill labor shortages has increased, so also has the outflow of Japanese to accompany direct foreign investment." excerpt

  8. Point-of-care ultrasound (POCUS) of the upper airway

    DEFF Research Database (Denmark)

    You-Ten, Kong Eric; Siddiqui, Naveed; Teoh, Wendy H

    2018-01-01

    is to provide an overview of the indications for point-of-care ultrasound (POCUS) of the upper airway. The use of US to guide and assist clinical airway management has potential benefits for both provider and patient. Ultrasound can be utilized to determine airway size and predict the appropriate diameter...... of single-lumen endotracheal tubes (ETTs), double-lumen ETTs, and tracheostomy tubes. Ultrasonography can differentiate tracheal, esophageal, and endobronchial intubation. Ultrasonography of the neck can accurately localize the cricothyroid membrane for emergency airway access and similarly identify...... tracheal rings for US-guided tracheostomy. In addition, US can identify vocal cord dysfunction and pathology before induction of anesthesia. A rapidly growing body of evidence showing ultrasonography used in conjunction with hands-on management of the airway may benefit patient care. Increasing awareness...

  9. Meeting the demand of the future: a curriculum to stimulate interest in careers in primary care internal medicine.

    Science.gov (United States)

    Hawthorne, Mary R; Dinh, An

    2017-01-01

    There is a growing need for primary care physicians, but only a small percentage of graduating medical students enter careers in primary care. To assess whether a Primary Care Intraclerkship within the Medicine clerkship can significantly improve students' attitudes by analyzing scores on pre- and post-tests. Students on the Medicine clerkship at the University of Massachusetts Medical School participated in full-day 'intraclerkships',to demonstrate the importance of primary care and the management of chronic illness in various primary care settings. Pre-and post-tests containing students' self-reported, five-point Likert agreement scale evaluations to 26 items (measuring perceptions about the roles of primary care physicians in patient care and treatment) were collected before and after each session. Eleven intraclerkships with 383 students were held between June 2010 and June 2013. Responses were analyzed using the GLM Model Estimate. Results from the survey analysis showed significantly more positive attitudes toward primary care in the post-tests compared to the pre-tests. Students who were satisfied with their primary care physicians were significantly more likely to show an improvement in post-test attitudes toward primary care in the areas of physicians improving the quality of patient care, making a difference in overall patient health, finding primary care as an intellectually challenging field, and in needing to collaborate with specialists. Older students were more likely than younger students to show more favorable answers on questions concerning the relative value of primary care vs. specialty care. A curriculum in Primary Care Internal Medicine can provide a framework to positively influence students' attitudes toward the importance of primary care, and potentially to influence career decisions to enter careers in Primary Care Internal Medicine. Ensuring that medical students receive excellent primary care for themselves can also positively influence

  10. [Struggling for normal in an instable situation - informal caregivers self-management in palliative home care. A meta-synthesis].

    Science.gov (United States)

    Kreyer, Christiane; Pleschberger, Sabine

    2014-10-01

    Family caregivers play a key role in palliative home care for persons with advanced cancer. Although research has shown numerous burdens and strains of family caregiving, there is a lack of family-oriented support strategies in palliative home care. Little is known about family caregivers' self-management in this context so far. Qualitative research provides insight into families' perspectives of the transition to and management of palliative care at home and can be used as a starting point. The aim of the study was to increase knowledge of family caregivers' self-management in palliative home care by synthesizing evidence from qualitative research. Based on a systematic review of literature a meta-synthesis was conducted following the approach of Noblit and Hare (1988). A total of 13 qualitative studies from six countries, published from 2002 onward, formed the basis for an interpretative synthesis. Caring for a person with advanced cancer at the end of life at home is characterized by an instable transition process in which families are 'struggling for normal'. Six different family self-management strategies to deal with this were identified: acknowledging the transition, restructuring everyday life, maintaining balance in family relationships, taking responsibility for care, using social support, and acquiring caring-skills. Self-management strategies may provide a key for supporting family caregivers in palliative home care by focusing on resources and problem solving skills of families.

  11. Water loss at normal enamel histological points during air drying at room temperature.

    Science.gov (United States)

    De Medeiros, R C G; De Lima, T A S; Gouveia, C R; De Sousa, F B

    2013-06-01

    This in vitro study aimed to quantify water loss at histological points in ground sections of normal enamel during air drying at room temperature (25°C) and relative humidity of 50%. From each of 10 ground sections of erupted permanent human normal enamel, three histological points (n = 30) located at 100, 300 and 500 μm from enamel surface and along a transversal following prisms paths were characterized regarding the mineral, organic and water volumes. Water loss during air drying was from 0 to 48 h. Drying occurred with both falling and constant-drying rates, and drying stabilization times (Teq ) ranged from 0.5 to 11 h with a mean 0.26 (±0.12)% weight loss. In some samples (n = 5; 15 points), Teq increased as a function of the distance from the enamel surface, and drying occurred at an apparent diffusion rate of 3.47 × 10⁻⁸ cm² s⁻¹. Our data provide evidence of air drying resulting in air replacing enamel's loosely bound water in prisms sheaths following a unidirectional water diffusion rate of 3.47 × 10⁻⁸ cm² s⁻¹ (from the original enamel surface inward), not necessarily resulting in water evaporating directly into air, with important implications for transport processes and optical and mechanical properties. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  12. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    Science.gov (United States)

    Steinfelder-Visscher, Jacoline; Teerenstra, Steven; Gunnewiek, Jacqueline M T Klein; Weerwind, Patrick W

    2008-03-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-month period, 48 blood samples from patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and 42 blood samples from non-cardiac patients who needed intensive care treatment were analyzed on both the i-STAT analyzer (CPB and non-CPB mode, respectively) and our laboratory analyzers (RapidLab 865/Sysmex XE-2100 instrument). The agreement analysis for quantitative data was used to compare i-STAT to RapidLab for blood gas/electrolytes and for hematocrit with the Sysmex instrument. Point-of-care electrolytes and blood gases had constant deviation, except for pH, pO2, and hematocrit. A clear linear trend in deviation of i-STAT from RapidLab was noticed for pH during CPB (r = 0.32, p = .03) and for pO2 > 10 kPa during CPB (r = -0.59, p pO2 pO2 pO2 range (10.6 pO2 range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation.

  13. Point-of-care lactate and creatinine analysis for sick obstetric patients at Queen Elizabeth Central Hospital in Blantyre, Malawi: A feasibility study.

    Science.gov (United States)

    Glasmacher, S A; Bonongwe, P; Stones, W

    2016-03-01

    To achieve good outcomes in critically ill obstetric patients, it is necessary to identify organ dysfunction rapidly so that life-saving interventions can be appropriately commenced. However, timely access to clinical chemistry results is problematic, even in referral institutions, in the sub-Saharan African region. Reliable point-of-care tests licensed for clinical use are now available for lactate and creatinine. We aimed to assess whether implementation of point-of-care testing for lactate and creatinine is feasible in the obstetric unit at the Queen Elizabeth Central Hospital (QECH) in Blantyre, Malawi, by obtaining the opinions of clinical staff on the use of these tests in practice. During a two-month evaluation period nurse-midwives, medical interns, clinical officers, registrars, and consultants were given the opportunity to use StatStrip® and StatSensor® (Nova Biomedical, Waltham, USA) devices, for lactate and creatinine estimation, as part of their routine clinical practice in the obstetric unit. They were subsequently asked to complete a short questionnaire. Thirty-seven questionnaires were returned by participants: 22 from nurse-midwives and the remainder from clinicians. The mean satisfaction score for the devices was 7.6/10 amongst clinicians and 8.0/10 amongst nurse-midwives. The majority of participants stated that the obstetric high dependency unit (HDU) was the most suitable location for the devices. For lactate, 31 participants strongly agreed that testing should be continued and 24 strongly agreed that it would influence patient management. For creatinine, 29 strongly agreed that testing should be continued and 28 strongly agreed that it would influence their patient management. Twenty participants strongly agreed that they trust point-of-care devices. Point-of-care clinical chemistry testing was feasible, practical, and well received by staff, and was considered to have a useful role to play in the clinical care of sick obstetric patients at

  14. Normalization Methods and Selection Strategies for Reference Materials in Stable Isotope Analyses - Review

    International Nuclear Information System (INIS)

    Skrzypek, G.; Sadler, R.; Paul, D.; Forizs, I.

    2011-01-01

    A stable isotope analyst has to make a number of important decisions regarding how to best determine the 'true' stable isotope composition of analysed samples in reference to an international scale. It has to be decided which reference materials should be used, the number of reference materials and how many repetitions of each standard is most appropriate for a desired level of precision, and what normalization procedure should be selected. In this paper we summarise what is known about propagation of uncertainties associated with normalization procedures and propagation of uncertainties associated with reference materials used as anchors for the determination of 'true' values for δ''1''3C and δ''1''8O. Normalization methods Several normalization methods transforming the 'raw' value obtained from mass spectrometers to one of the internationally recognized scales has been developed. However, as summarised by Paul et al. different normalization transforms alone may lead to inconsistencies between laboratories. The most common normalization procedures are: single-point anchoring (versus working gas and certified reference standard), modified single-point normalization, linear shift between the measured and the true isotopic composition of two certified reference standards, two-point and multipoint linear normalization methods. The accuracy of these various normalization methods has been compared by using analytical laboratory data by Paul et al., with the single-point and normalization versus tank calibrations resulting in the largest normalization errors, and that also exceed the analytical uncertainty recommended for δ 13 C. The normalization error depends greatly on the relative differences between the stable isotope composition of the reference material and the sample. On the other hand, the normalization methods using two or more certified reference standards produces a smaller normalization error, if the reference materials are bracketing the whole range of

  15. Point-of-care testing of HbA1c in diabetes care and preventable hospital admissions

    DEFF Research Database (Denmark)

    Kristensen, Troels; Rose Olsen, Kim; Skovsgaard, Christian

    Background: Point-of-care testing (POCT) of HbA1c may result in improved diabetic control, better patient outcomes and enhanced clinical efficiency with fewer patient visits and subsequent reductions in hospitalizations and costs. In 2008, the Danish regulators agreed to create a new tariff for t...

  16. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Towards a point-of-care strip test to diagnose sickle cell anemia.

    Directory of Open Access Journals (Sweden)

    Meaghan Bond

    Full Text Available A rapid test to identify patients with sickle cell disease could have important benefits in low-resource settings. Sickle cell anemia (SCA affects about 300,000 newborns each year, the majority of whom are born in sub-Saharan Africa. Low-cost therapies are available to treat SCA, but most countries in sub-Saharan Africa lack robust neonatal screening programs needed to identify patients in need of treatment. To address this need, we developed and evaluated a competitive lateral flow assay that identifies patients with SCA (genotype HbSS in 15 minutes using undiluted whole blood. A small volume of blood (0.5 μL- 3 μL is mixed with antibody-coated blue latex beads in a tube and applied to the strip. Strips are then placed in a well of running buffer and allowed to run for 10 minutes. Laboratory evaluation with samples containing different proportions of hemoglobin A (HbA and hemoglobin S (HbS indicated that the test should enable identification of SCA patients but not persons with sickle cell trait (SCT. We evaluated the test using 41 samples from individuals with SCA, SCT, and normal blood. With visual inspection or quantitative analysis, we found a 98% accuracy when differentiating SCA from normal and SCT samples as a group (90% sensitivity and 100% specificity for identifying SCA. This work demonstrates important steps towards making a lateral flow test for hemoglobinopathies more appropriate for point-of-care use; further work is needed before the test is appropriate for clinical use.

  18. Point of Care Testing Services Delivery: Policy Analysis using a ...

    African Journals Online (AJOL)

    Annals of Biomedical Sciences ... The service providers (hospital management) and the testing personnel are faced with the task of trying to explain these problems. Objective of the study: To critically do a policy analysis of the problems of point of care testing with the aim of identifying the causes of these problems and ...

  19. Variation in point-of-care testing of HbA1c in diabetes care general practice

    DEFF Research Database (Denmark)

    Kristensen, Troels

    2016-01-01

    Background and Aims Point-of-care testing (POCT) for HbA1c may result in improved diabetic control, better patient outcomes and enhanced clinical efficiency with fewer patient visits and subsequent reductions in costs. In 2008, the Danish regulators agreed to create a new fee for the remuneration...

  20. Point-of-care echocardiography in simulation-based education and assessment

    Directory of Open Access Journals (Sweden)

    Amini R

    2016-05-01

    Full Text Available Richard Amini, Lori A Stolz, Parisa P Javedani, Kevin Gaskin, Nicola Baker, Vivienne Ng, Srikar Adhikari Department of Emergency Medicine, University of Arizona Medical Center, Tucson, AZ, USA Background: Emergency medicine milestones released by the Accreditation Council for Graduate Medical Education require residents to demonstrate competency in bedside ultrasound (US. The acquisition of these skills necessitates a combination of exposure to clinical pathology, hands-on US training, and feedback. Objectives: We describe a novel simulation-based educational and assessment tool designed to evaluate emergency medicine residents’ competency in point-of-care echocardiography for evaluation of a hypotensive patient with chest pain using bedside US. Methods: This was a cross-sectional study conducted at an academic medical center. A simulation-based module was developed to teach and assess the use of point-of-care echocardiography in the evaluation of the hypotensive patient. The focus of this module was sonographic imaging of cardiac pathology, and this focus was incorporated in all components of the session: asynchronous learning, didactic lecture, case-based learning, and hands-on stations. Results: A total of 52 residents with varying US experience participated in this study. Questions focused on knowledge assessment demonstrated improvement across the postgraduate year (PGY of training. Objective standardized clinical examination evaluation demonstrated improvement between PGY I and PGY III; however, it was noted that there was a small dip in hands-on scanning skills during the PGY II. Clinical diagnosis and management skills also demonstrated incremental improvement across the PGY of training. Conclusion: The 1-day, simulation-based US workshop was an effective educational and assessment tool at our institution. Keywords: point-of care ultrasound, simulation education

  1. Service quality of delivered care from the perception of women with caesarean section and normal delivery.

    Science.gov (United States)

    Tabrizi, Jafar S; Askari, Samira; Fardiazar, Zahra; Koshavar, Hossein; Gholipour, Kamal

    2014-01-01

    Our aim was to determine the service quality of delivered care for people with Caesarean Section and Normal Delivery. A cross-sectional study was conducted among 200 people who had caesarean section and normal delivery in Al-Zahra Teaching Hospital in Tabriz, north western Iran. Service quality was calculated using: Service Quality = 10 - (Importance × Performance) based on importance and performance of service quality aspects from the postpartum women's perspective.A hierarchical regression analysis was applied in two steps using the enter method to examine the associations between demographics and SQ scores. Data were analysed using the SPSS-17 software. "Confidentiality", "autonomy", "choice of care provider" and "communication" achieved scores at the highest level of quality; and "support group", "prompt attention", "prevention and early detection", "continuity of care", "dignity", "safety", "accessibility and "basic amenities" got service quality score less than eight. Statistically significant relationship was found between service quality score and continuity of care (P=0.008). A notable gap between the participants‟ expectations and what they have actually received in most aspects of provided care. So, there is an opportunityto improve the quality of delivered care.

  2. Psychometric Properties of the Thai Internalized Stigma Scale (TIS-LCH) for Care Home Residents.

    Science.gov (United States)

    Tosangwarn, Suhathai; Clissett, Philip; Blake, Holly

    2017-01-01

    Living in a care home is a source of stigma in Thai culture, although there is currently no measurement tool in the Thai language specifically designed to assess internalized stigma in care home residents. The Thai Version of Internalized Stigma of Living in a Care Home (TIS-LCH) scale was developed and tested for its psychometric properties among Thai older residents. The Thai version of Internalized Stigma of Mental Health Illness (ISMI) Scale was revised into the TIS-LCH by replacing the word of "mental health illness" to "living in a care home." Content validity of the TIS-LCH was determined through expert review (n = 6), and reliability testing was undertaken with older care home residents (n = 128). The TIS-LCH showed good internal consistency, with a Cronbach's alpha of .87. Test-retest reliability coefficient of TIS-LCH was excellent for the full scale (ICC = .90). The Thai version of IS-LCH (TIS-LCH) is a valid and reliable measurement tool for assessing internalized stigma in Thai care home residents. The IS-LCH will be a useful research tool to assess internalized stigma in older adults living in care settings. Understanding stigma will help health and social care professionals to plan interventions aimed at reducing or preventing negative emotional reactions and negative behavioural responses toward stigma, which are known to be associated with mental illness and particularly depression among this population.

  3. Cholesterol Point-of-Care Testing for Community Pharmacies: A Review of the Current Literature.

    Science.gov (United States)

    Haggerty, Lauren; Tran, Deanna

    2017-08-01

    To summarize the literature on cholesterol point-of-care tests (POCTs). This article would serve as a resource to assist community pharmacists in developing cholesterol point-of-care (POC) pharmacy services. A literature search was performed in MEDLINE Ovid, PubMed, EMBASE, and Cochrane database using the following medical subject headings (MeSH) terms: point-of-care test, cholesterol, blood chemical analysis, rapid testing, collaborative practice, community pharmacy, and ambulatory care. Additional resources including device manufacturer web sites were summarized to supplement the current literature. All human research articles, review articles, meta-analyses, and abstracts published in English through September 1, 2014, were considered. A total of 36 articles were applicable for review. Information was divided into the following categories to be summarized: devices, pharmacists' impact, and operational cost for the pharmacy. The current literature suggests that POCTs in community pharmacies assist with patient outcomes by providing screenings and referring patients with dyslipidemia for further evaluation. The majority of studies on cholesterol POC devices focused on accuracy, revealing the need for further studies to develop best practices and practice models with successful reimbursement. Accuracy, device specifications, required supplies, and patient preference should be considered when selecting a POC device for purchase.

  4. International medical law and its impact on the ukrainian health care legislation.

    Science.gov (United States)

    Pashkov, Vitalii; Udovyka, Larysa; Dichko, Hanna

    2018-01-01

    Introduction: The Ukrainian state has an urgent necessity of rapid search for essentially new legal and organizational forms of the healthcare system, reform of the legal regulation of healthcare services provision. In the context of European integration, the advancement of the medical industry reform is closely related to consideration of international standards and norms of health care. The aim: To study the impact of international medical law on the Ukrainian health care legislation. Materials and methods: International and Ukrainian regulations and documents on health care were used in the research. System and structural, functional and legal comparative methods as well as systematization, analysis and synthesis were determinative in the research process. Review: Systematization of international documents on health care was made. The major problems in the Ukrainian health care legislation were determined in terms of their conformity with the international legislative norms. The expediency of the Medical Code adoption was grounded and its structure was defined. Conclusions: Most health care international acts are ratified by Ukraine and their provisions are implemented in the legislation. Simultaneously, there is a row of problems, which hinder the Ukrainian health care development and place obstacles in the way of European integration. To remove these obstacles, it is expedient to create a codified act - the Medical Code, which would systematize the provisions of the current medical laws and regulations and fill in the existing gaps in the legal regulation of health care.

  5. Checklist for Early Recognition and Treatment of Acute Illness (CERTAIN): evolution of a content management system for point-of-care clinical decision support.

    Science.gov (United States)

    Barwise, Amelia; Garcia-Arguello, Lisbeth; Dong, Yue; Hulyalkar, Manasi; Vukoja, Marija; Schultz, Marcus J; Adhikari, Neill K J; Bonneton, Benjamin; Kilickaya, Oguz; Kashyap, Rahul; Gajic, Ognjen; Schmickl, Christopher N

    2016-10-03

    The Checklist for Early Recognition and Treatment of Acute Illness (CERTAIN) is an international collaborative project with the overall objective of standardizing the approach to the evaluation and treatment of critically ill patients world-wide, in accordance with best-practice principles. One of CERTAIN's key features is clinical decision support providing point-of-care information about common acute illness syndromes, procedures, and medications in an index card format. This paper describes 1) the process of developing and validating the content for point-of-care decision support, and 2) the content management system that facilitates frequent peer-review and allows rapid updates of content across different platforms (CERTAIN software, mobile apps, pdf-booklet) and different languages. Content was created based on survey results of acute care providers and validated using an open peer-review process. Over a 3 year period, CERTAIN content expanded to include 67 syndrome cards, 30 procedure cards, and 117 medication cards. 127 (59 %) cards have been peer-reviewed so far. Initially MS Word® and Dropbox® were used to create, store, and share content for peer-review. Recently Google Docs® was used to make the peer-review process more efficient. However, neither of these approaches met our security requirements nor has the capacity to instantly update the different CERTAIN platforms. Although we were able to successfully develop and validate a large inventory of clinical decision support cards in a short period of time, commercially available software solutions for content management are suboptimal. Novel custom solutions are necessary for efficient global point of care content system management.

  6. The reliability of point-of-care prothrombin time testing. A comparison of CoaguChek S and XS INR measurements with hospital laboratory monitoring.

    LENUS (Irish Health Repository)

    Ryan, F

    2010-02-01

    The development of point-of-care (POC) testing devices enables patients to test their own international normalized ratio (INR) at home. However, previous studies have shown that when compared with clinical laboratory values, statistically significant differences may occur between the two methods of INR measurement. The aim of this study was to evaluate the accuracy of the CoaguChek S and XS POC meters relative to clinical laboratory measurements. As part of a randomized, crossover patient self-testing (PST) study at Cork University Hospital, patients were randomized to 6 months PST or 6 months routine care by the anticoagulation management service. During the PST arm of the study, patients measured their INR at home using the CoaguChek S or XS POC meter. External quality control was performed at enrollment, 2 months and 4 months by comparing the POC measured INR with the laboratory determined value. One hundred and fifty-one patients provided 673 paired samples. Good correlation was shown between the two methods of determination (r = 0.91), however, statistically significant differences did occur. A Bland-Altman plot illustrated good agreement of INR values between 2.0 and 3.5 INR units but there was increasing disagreement as the INR rose above 3.5. Eighty-seven per cent of all dual measurements were within the recommended 0.5 INR units of each other. This study adds to the growing evidence that POC testing is a reliable and safe alternative to hospital laboratory monitoring but highlights the importance of external quality control when these devices are used for monitoring oral anticoagulation.

  7. Point of care hand hygiene-where's the rub? A survey of US and Canadian health care workers' knowledge, attitudes, and practices.

    Science.gov (United States)

    Kirk, Jane; Kendall, Anson; Marx, James F; Pincock, Ted; Young, Elizabeth; Hughes, Jillian M; Landers, Timothy

    2016-10-01

    Hand hygiene at the point of care is recognized as a best practice for promoting compliance at the moments when hand hygiene is most critical. The objective of this study was to compare knowledge, attitudes, and practices of US and Canadian frontline health care personnel regarding hand hygiene at the point of care. Physicians and nurses in US and Canadian hospitals were invited to complete a 32-question online survey based on evidence supporting point of care hand hygiene. Eligible health care personnel were in direct clinical practice at least 50% of the time. Three hundred fifty frontline caregivers completed the survey. Among respondents, 57.1% were from the United States and 42.9% were from Canada. Respondents were evenly distributed between physician and nurses. The US and Canadian respondents gave identical ranking to their perceived barriers to hand hygiene compliance. More than half of the respondents from both the United States and Canada agreed or strongly agreed that they would be more likely to clean their hands when recommended if alcohol-based handrub was closer to the patient. This survey demonstrates that similarities between Canada and the United States were more common than not, and the survey raises, or suggests, potential knowledge gaps that require further illumination. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. All-polymer biosensor for label-free point of care diagnostics

    DEFF Research Database (Denmark)

    Dapra, Johannes

    2013-01-01

    without the need for a specialised laboratory. Other fields of application are for example health care projects in developing countries where access to modern high-throughput facilities is often impossible or sectors not related to the medical field, like environmental monitoring or food safety. The aim......Personalised medicine and diagnostics is a rapidly growing field of research and general interest. Important tools for individual patient care are so called point-of-care devices. These typically simple and inexpensive instruments allow the untrained user to perform simple diagnostic analyses...... of this PhD project was to develop a modular platform based on electrochemical impedimetric sensing. This device can easily be modified by changing the biological receptors and therefore offers a broad range of possible applications. To keep the costs and the environmental footprint low the entire biosensor...

  9. The effects of integrated care: a systematic review of UK and international evidence.

    Science.gov (United States)

    Baxter, Susan; Johnson, Maxine; Chambers, Duncan; Sutton, Anthea; Goyder, Elizabeth; Booth, Andrew

    2018-05-10

    Healthcare systems around the world have been responding to the demand for better integrated models of service delivery. However, there is a need for further clarity regarding the effects of these new models of integration, and exploration regarding whether models introduced in other care systems may achieve similar outcomes in a UK national health service context. The study aimed to carry out a systematic review of the effects of integration or co-ordination between healthcare services, or between health and social care on service delivery outcomes including effectiveness, efficiency and quality of care. Electronic databases including MEDLINE; Embase; PsycINFO; CINAHL; Science and Social Science Citation Indices; and the Cochrane Library were searched for relevant literature published between 2006 to March 2017. Online sources were searched for UK grey literature, and citation searching, and manual reference list screening were also carried out. Quantitative primary studies and systematic reviews, reporting actual or perceived effects on service delivery following the introduction of models of integration or co-ordination, in healthcare or health and social care settings in developed countries were eligible for inclusion. Strength of evidence for each outcome reported was analysed and synthesised using a four point comparative rating system of stronger, weaker, inconsistent or limited evidence. One hundred sixty seven studies were eligible for inclusion. Analysis indicated evidence of perceived improved quality of care, evidence of increased patient satisfaction, and evidence of improved access to care. Evidence was rated as either inconsistent or limited regarding all other outcomes reported, including system-wide impacts on primary care, secondary care, and health care costs. There were limited differences between outcomes reported by UK and international studies, and overall the literature had a limited consideration of effects on service users. Models of

  10. Features of the Japanese national dementia strategy in comparison with international dementia policies: How should a national dementia policy interact with the public health- and social-care systems?

    Science.gov (United States)

    Nakanishi, Miharu; Nakashima, Taeko

    2014-07-01

    The Ministry of Health, Labour, and Welfare of the Japanese national government announced a "Five-Year Plan for Promotion of Measures Against Dementia (Orange Plan)" in September 2012. This article described features of the Japanese dementia strategy in comparison with international dementia policies. An international comparative study was implemented on national dementia policies to seek suggestions for Japanese national strategy. The study consisted of a bibliographical survey, a field survey, and an online case vignette survey in several countries. The Japanese health- and social-care system had multiple access points in the dementia care pathway, as did Australia, France, South Korea, and the Netherlands. Contrary to Japan, a simplified access point was observed in Denmark, England, and Sweden. The Orange Plan aimed to establish specific health-care services, social-care services, and the coordination of agencies for persons with dementia. However, fragmentation remains in the dementia care pathway. The national government should examine fundamental revisions in health, social-care services, and advocacy in joint initiatives with Alzheimer's Association Japan to improve the national dementia strategy. Copyright © 2014 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  11. Advances in point-of-care ultrasound in pediatric emergency medicine.

    Science.gov (United States)

    Gallagher, Rachel A; Levy, Jason A

    2014-06-01

    Point-of-care ultrasound (POCUS) has become an integral part of emergency medicine practice. Research evaluating POCUS in the care of pediatric patients has improved the understanding of its potential role in clinical care. Recent work has investigated the ability of pediatric emergency medicine (PEM) physicians to perform a wide array of diagnostic and procedural applications in POCUS ultrasound. Studies have demonstrated that PEM providers are able to identify an array of diseases, including intussusception, pyloric stenosis and appendicitis. Novel applications of ultrasound, such as a cardiac evaluation in the acutely ill patient or identification of skull fractures in the assessment of a patient with head injury, have shown excellent promise in recent studies. These novel applications have the potential to reshape pediatric diagnostic algorithms. Key applications in PEM have been investigated in the recent publications. Further exploration of the ability to integrate ultrasound into routine practice will require larger-scale studies and continued growth of education in the field. The use of ultrasound in clinical practice has the potential to improve safety and efficiency of care in the pediatric emergency department.

  12. Point-of-care ultrasound in aerospace medicine: known and potential applications.

    Science.gov (United States)

    Wagner, Michael S; Garcia, Kathleen; Martin, David S

    2014-07-01

    Since its initial introduction into the bedside assessment of the trauma patient via the Focused Assessment with Sonography for Trauma (FAST) exam, the use of point-of-care ultrasound has expanded rapidly. A growing body of literature demonstrates ultrasound can be used by nonradiologists as an extension of the physical exam to accurately diagnose or exclude a variety of conditions. These conditions include, but are not limited to, hemoperitoneum, pneumothorax, pulmonary edema, long-bone fracture, deep vein thrombosis, and elevated intracranial pressure. As ultrasound machines have become more compact and portable, their use has extended outside of hospitals to places where the physical exam and diagnostic capabilities may be limited, including the aviation environment. A number of studies using focused sonography have been performed to meet the diagnostic challenges of space medicine. The following article reviews the available literature on portable ultrasound use in aerospace medicine and highlights both known and potential applications of point-of-care ultrasound for the aeromedical clinician.

  13. Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer

    Science.gov (United States)

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375

  14. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.

    Science.gov (United States)

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.

  15. Normalized Point Source Sensitivity for Off-Axis Optical Performance Evaluation of the Thirty Meter Telescope

    Science.gov (United States)

    Seo, Byoung-Joon; Nissly, Carl; Troy, Mitchell; Angeli, George

    2010-01-01

    The Normalized Point Source Sensitivity (PSSN) has previously been defined and analyzed as an On-Axis seeing-limited telescope performance metric. In this paper, we expand the scope of the PSSN definition to include Off-Axis field of view (FoV) points and apply this generalized metric for performance evaluation of the Thirty Meter Telescope (TMT). We first propose various possible choices for the PSSN definition and select one as our baseline. We show that our baseline metric has useful properties including the multiplicative feature even when considering Off-Axis FoV points, which has proven to be useful for optimizing the telescope error budget. Various TMT optical errors are considered for the performance evaluation including segment alignment and phasing, segment surface figures, temperature, and gravity, whose On-Axis PSSN values have previously been published by our group.

  16. Best-Matched Internal Standard Normalization in Liquid Chromatography-Mass Spectrometry Metabolomics Applied to Environmental Samples.

    Science.gov (United States)

    Boysen, Angela K; Heal, Katherine R; Carlson, Laura T; Ingalls, Anitra E

    2018-01-16

    The goal of metabolomics is to measure the entire range of small organic molecules in biological samples. In liquid chromatography-mass spectrometry-based metabolomics, formidable analytical challenges remain in removing the nonbiological factors that affect chromatographic peak areas. These factors include sample matrix-induced ion suppression, chromatographic quality, and analytical drift. The combination of these factors is referred to as obscuring variation. Some metabolomics samples can exhibit intense obscuring variation due to matrix-induced ion suppression, rendering large amounts of data unreliable and difficult to interpret. Existing normalization techniques have limited applicability to these sample types. Here we present a data normalization method to minimize the effects of obscuring variation. We normalize peak areas using a batch-specific normalization process, which matches measured metabolites with isotope-labeled internal standards that behave similarly during the analysis. This method, called best-matched internal standard (B-MIS) normalization, can be applied to targeted or untargeted metabolomics data sets and yields relative concentrations. We evaluate and demonstrate the utility of B-MIS normalization using marine environmental samples and laboratory grown cultures of phytoplankton. In untargeted analyses, B-MIS normalization allowed for inclusion of mass features in downstream analyses that would have been considered unreliable without normalization due to obscuring variation. B-MIS normalization for targeted or untargeted metabolomics is freely available at https://github.com/IngallsLabUW/B-MIS-normalization .

  17. International palliative care research in the context of global development: a systematic mapping review.

    Science.gov (United States)

    Clark, Joseph; Gardiner, Clare; Barnes, Amy

    2018-03-01

    An increasing amount of health policy is formulated at global level. At this global level, palliative care has attracted support primarily from normative institutions (WHO), not funding agencies. To attract greater global attention from policymakers, it has been argued that an international approach to research is required. However, the extent to which an international approach is being undertaken is unknown. To systematically identify and thematically synthesise all international palliative care research, defined as research involving two or more countries, or focused on the global level. Five bibliographic databases (CINAHL, Cochrane Library, ASSIA, Web of Knowledge, Psychinfo) were searched for journal articles relevant to international and global palliative care and end-of-life care. Data were extracted using a piloted extraction form and findings were synthesised. 184 studies were included, published across 75 different academic journals. Research emanates from and focuses on all world regions and there is increasing focus on the global level. Thematically, there is a high focus on Evaluation (n=53) and views of Stakeholders (n=38). The review revealed a predominantly observational research approach and few interventional studies were identified. International palliative care research is a relatively new, but growing field. However, many gaps in the evidence base remain and palliative care research continues to take place outside broader discourses of international development. The relative absence of interventional research demonstrating the effectiveness and cost-effectiveness of palliative care risks limiting the tools with which advocates can engage with international policymakers on this topic. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Reactor internals design/analysis for normal, upset, and faulted conditions

    International Nuclear Information System (INIS)

    Burke, F.R.

    1977-06-01

    The analytical procedures used by Babcock and Wilcox to demonstrate the structural integrity of the 205-FA reactor internals are described. Analytical results are presented and compared to ASME Code allowable limits for Normal, Upset, and Faulted conditions. The particular faulted condition considered is a simultaneous loss-of-coolant accident and safe shutdown earthquake. The operating basis earthquake is addressed as an Upset condition

  19. Perceptions of point-of-care infectious disease testing among European medical personnel, point-of-care test kit manufacturers, and the general public

    Directory of Open Access Journals (Sweden)

    Kaman WE

    2013-06-01

    Full Text Available Wendy E Kaman,1 Eleni-Rosalina Andrinopoulou,2 John P Hays11Department of Medical Microbiology and Infectious Diseases, Erasmus Medical Center, Rotterdam, The Netherlands; 2Department of Biostatistics, Erasmus Medical Center, Rotterdam, The NetherlandsBackground: The proper development and implementation of point-of-care (POC diagnostics requires knowledge of the perceived requirements and barriers to their implementation. To determine the current requirements and perceived barriers to the introduction of POC diagnostics in the field of medical microbiology (MM-POC a prospective online survey (TEMPOtest-QC was established.Methods and results: The TEMPOtest-QC survey was online between February 2011 and July 2012 and targeted the medical community, POC test diagnostic manufacturers, general practitioners, and the general public. In total, 293 individuals responded to the survey, including 91 (31% medical microbiologists, 39 (13% nonmedical microbiologists, 25 (9% employees of POC test manufacturers, and 138 (47% members of the general public. Responses were received from 18 different European countries, with the largest percentage of these living in The Netherlands (52%. The majority (>50% of medical specialists regarded the development of MM-POC for blood culture and hospital acquired infections as “absolutely necessary”, but were much less favorable towards their use in the home environment. Significant differences in perceptions between medical specialists and the general public included the: (1 Effect on quality of patient care; (2 Ability to better monitor patients; (3 Home testing and the doctor-patient relationship; and (4 MM-POC interpretation. Only 34.7% of the general public is willing to pay more than €10 ($13 for a single MM-POC test, with 85.5% preferring to purchase their MM-POC test from a pharmacy.Conclusion: The requirements for the proper implementation of MM-POC were found to be generally similar between medical

  20. Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow diagnostic device.

    Science.gov (United States)

    Hegener, Michael A; Li, Hua; Han, Daewoo; Steckl, Andrew J; Pauletti, Giovanni M

    2017-09-01

    Vitamin K antagonists such as warfarin are the most widely used class of oral anticoagulants. Due to a narrow therapeutic window, patients on warfarin require regular monitoring. Self-testing using point-of-care (POC) diagnostic devices is available, but cost makes this monitoring method beyond reach for many. The main objective of this research was to assess the clinical utility of a low-cost, paper-based lateral flow POC diagnostic device developed for anticoagulation monitoring without the need for a separate electronic reader. Custom-fabricated lateral flow assay (LFA) test strips comprised of a glass fiber sample pad, a nitrocellulose analytical membrane, a cellulose wicking pad, and a plastic backing card were assembled in a plastic cassette. Healthy volunteers and patients on warfarin therapy were recruited for this prospective study. For each participant, a whole blood sample was collected via fingerstick to determine: (1) international normalized ratio (INR) using the CoaguChek® XS coagulometer, (2) hematocrit by centrifugation, and (3) red blood cell (RBC) travel distance on the experimental LFA device after 240 s using digital image analysis. RBC travel distance measured on the LFA device using blood samples obtained from warfarin patients positively correlated with increasing INR value and the LFA device had the capability to statistically distinguish between healthy volunteer INR values and those for patients groups with INR ≥ 2.6. From these data, it is predicted that this low-cost, paper-based LFA device can have clinical utility for identifying anticoagulated patients taking vitamin K antagonists who are outside of the desired therapeutic efficacy window.

  1. Point-of-Care Ultrasound in the Evaluation of Pyogenic Flexor Tenosynovitis.

    Science.gov (United States)

    Cohen, Stephanie G; Beck, Sierra C

    2015-11-01

    A 4-year-old girl presented to the emergency department for evaluation of finger swelling after a dog bite. Point-of-care ultrasound was used to diagnose pyogenic flexor tenosynovitis of the digit after visualizing a fluid collection within the flexor tendon sheath. The patient underwent emergent incision and drainage of the digit with good outcome.

  2. An Instantaneous Low-Cost Point-of-Care Anemia Detection Device

    Directory of Open Access Journals (Sweden)

    Jaime Punter-Villagrasa

    2015-02-01

    Full Text Available We present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 µL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%.

  3. Variation in Point-of-Care Testing of HbA1c in Diabetes Care in General Practice

    DEFF Research Database (Denmark)

    Kristensen, Troels; Waldorff, Frans Boch; Nexøe, Jørgen

    2017-01-01

    Background: Point-of-care testing (POCT) of HbA1c may result in improved diabetic control, better patient outcomes, and enhanced clinical efficiency with fewer patient visits and subsequent reductions in costs. In 2008, the Danish regulators created a framework agreement regarding a new fee-for-s...

  4. Satisfaction with the local service point for care: results of an evaluation study

    Science.gov (United States)

    Esslinger, Adelheid Susanne; Macco, Katrin; Schmidt, Katharina

    2009-01-01

    Purpose The market of care increases and is characterized by complexity. Therefore, service points, such as the ‘Zentrale Anlaufstelle Pflege (ZAPf)’ in Nuremberg, are helpful for clients to get orientation. The purpose of the presentation is to show the results of an evaluation study about the clients' satisfaction with the offers of ZAPf. Study Satisfaction with service may be measured with the SERVQUAL concept introduced by Parasuraman et al. (1988). They found out five dimensions of quality (tangibles, reliability, responsiveness, assurances and empathy). We took these dimensions in our study. The study focuses on the quality of service and the benefits recognized by clients. In spring 2007, we conducted 67 interviews by phone, based on a half standardized questionnaire. Statistical analysis was conducted using SPSS. Results The clients want to get information about care in general, financial and legal aspects, alternative care arrangement (e.g. ambulant, long-term care) and typical age-related diseases. They show a high satisfaction with the service provided. Their benefits are to get information and advice, to strengthen the ability of decision taking, to cope with changing situations in life, and to develop solutions. Conclusions The results show that the quality of service is on a high level. Critical success factors are the interdisciplinary cooperation at the service point, based on a regularly and open exchange of information. Every member focuses on an optimal individual solution for the client. Local professional service points act as networkers and brokers. They serve not only for the clients' needs but also support the effective and efficient provision of optimized care.

  5. Comparability of Point-of-Care versus Central Laboratory Hemoglobin Determination in Emergency Patients at a Supra-Maximal Care Hospital.

    Directory of Open Access Journals (Sweden)

    Ramona C Dolscheid-Pommerich

    Full Text Available Fulfilling the requirements of point-of-care testing (POCT training regarding proper execution of measurements and compliance with internal and external quality control specifications is a great challenge. Our aim was to compare the values of the highly critical parameter hemoglobin (Hb determined with POCT devices and central laboratory analyzer in the highly vulnerable setting of an emergency department in a supra maximal care hospital to assess the quality of POCT performance. In 2548 patients, Hb measurements using POCT devices (POCT-Hb were compared with Hb measurements performed at the central laboratory (Hb-ZL. Additionally, sub collectives (WHO anemia classification, patients with Hb 85y. were analyzed. Overall, the correlation between POCT-Hb and Hb-ZL was highly significant (r = 0.96, p2.5g/dl occurred. McNemar´s test revealed significant differences regarding anemia diagnosis according to WHO definition for male, female and total patients (♂ p<0.001; ♀ p<0.001, total p<0.001. Hb-ZL resulted significantly more often in anemia diagnosis. In samples with Hb<8g/dl, McNemar´s test yielded no significant difference (p = 0.169. In suprageriatric patients, McNemar´s test revealed significant differences regarding anemia diagnosis according to WHO definition in male, female and total patients (♂ p<0.01; ♀ p = 0.002, total p<0.001. The difference between Hb-ZL and POCT-Hb with Hb<8g/dl was not statistically significant (<8g/dl, p = 1.000. Overall, we found a highly significant correlation between the analyzed hemoglobin concentration measurement methods, i.e. POCT devices and at the central laboratory. The results confirm the successful implementation of the presented POCT concept. Nevertheless some limitations could be identified in anemic patients stressing the importance of carefully examining clinically implausible results.

  6. Data analysis strategies for the characterization of normal: superconductor point contacts by barrier strength parameter

    Science.gov (United States)

    Smith, Charles W.; Reinertson, Randal C.; Dolan, P. J., Jr.

    1993-05-01

    The theoretical description by Blonder, Tinkham, and Klapwijk [Phys. Rev. B 25, 4515 (1982)] of the I-V curves of normal: superconductor point contacts encompasses a broad range of experimental behavior, from the tunnel junction case, on the one hand, to the clean metallic microconstriction limit on the other. The theory characterizes point contacts in terms of a single parameter, the barrier strength. The differential conductance of a point contact, at zero bias, as a function of temperature, offers a direct experimental method by which the barrier strength parameter can be evaluated. In view of the full range of phenomena incorporated by this theory, we suggest several different strategies for the evaluation of the barrier strength parameter from data in the low and intermediate barrier strength regimes and for measurements in the low temperature (near T=0 K) and high temperature (near T=Tc) limits.

  7. Health Care for the International Student: Asia and the Pacific.

    Science.gov (United States)

    Naughton, June C., Ed.; And Others

    This handbook consists of 24 papers addressing various aspects on health care and health care systems and services for foreign students from the Asia Pacific Region. The papers are: "Providing Health Care for International Students" (Donald F. B. Char); "Major Health Care Systems in Asia and the Pacific: Mainland China, Taiwan, Hong…

  8. Towards Detection and Diagnosis of Ebola Virus Disease at Point-of-Care

    Science.gov (United States)

    Kaushik, Ajeet; Tiwari, Sneham; Jayant, Rahul Dev; Marty, Aileen; Nair, Madhavan

    2015-01-01

    Ebola outbreak-2014 (mainly Zaire strain related Ebola virus) has been declared most widely spread deadly persistent epidemic due to unavailability of rapid diagnostic, detection, and therapeutics. Ebola virus disease (EVD), a severe viral hemorrhagic fever syndrome caused by Ebola virus (EBOV) is transmitted by direct contact with the body fluids of infected person and objects contaminated with virus or infected animals. World Health Organization (WHO) has declared EVD epidemic as public health emergency of international concern with severe global economic burden. At fatal EBOV infection stage, patients usually die before the antibody response. Currently, rapid blood tests to diagnose EBOV infection include the antigen or antibodies capture using ELISA and RNA detection using RT/Q-PCR within 3–10 days after the onset of symptoms. Moreover, few nanotechnology-based colorimetric and paper-based immunoassay methods have been recently reported to detect Ebola virus. Unfortunately, these methods are limited to laboratory only. As state-of-the art (SoA) diagnostics time to confirm Ebola infection, varies from 6 hours to about 3 days, it causes delay in therapeutic approaches. Thus developing a cost-effective, rapid, sensitive, and selective sensor to detect EVD at point-of-care (POC) is certainly worth exploring to establish rapid diagnostics to decide therapeutics. This review highlights SoA of Ebola diagnostics and also a call to develop rapid, selective and sensitive POC detection of EBOV for global health care. We propose that adopting miniaturized electrochemical EBOV immunosensing can detect virus level at pM concentration within ~40 minute compared to 3 days of ELISA test at nM levels. PMID:26319169

  9. Comparability of Results between Point-of-Care and Automated Instruments to Measure B-type Natriuretic Peptide

    OpenAIRE

    Shah, Kevin; Terracciano, Garrett J.; Jiang, Kevin; Maisel, Alan S.; Fitzgerald, Robert L.

    2010-01-01

    Objectives: Heart failure is one of the leading causes of death in the U.S. The incorporation of B-type natriuretic peptide (BNP) measurements when triaging patients presenting with shortness of breath has improved the diagnostic and prognostic ability of physicians. Currently, there are no point-of-care systems for quantifying BNP that can be used without sacrificing accuracy. We compared the analytical performance of the Abbott i-STAT analyzer, a handheld point-of-care system for measuring ...

  10. Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices

    Directory of Open Access Journals (Sweden)

    Bart Verhees

    2017-12-01

    Full Text Available Point-of-care testing (POCT—laboratory tests performed with new mobile devices and online technologies outside of the central laboratory—is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP’s network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre.

  11. Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices.

    Science.gov (United States)

    Verhees, Bart; van Kuijk, Kees; Simonse, Lianne

    2017-12-21

    Point-of-care testing (POCT)-laboratory tests performed with new mobile devices and online technologies outside of the central laboratory-is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP's network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre.

  12. Raised international normalized ratio: an early warning for a late cardiac tamponade?

    NARCIS (Netherlands)

    Shah, Ammad; van den Brink, Albert; de Mol, Bas

    2006-01-01

    Seven consecutive cases of late cardiac tamponade after valvular surgery are reported; all were postoperatively treated with acenocoumarol and 6 had an international normalized ratio peak greater than 6.0 within 3 days preceding tamponade. It is suggested that during this excessive anticoagulation

  13. We are not alone: international learning for professionals caring for children requiring palliative care.

    Science.gov (United States)

    Price, Jayne; Quinn, Karen; McNeilly, Patricia; Heywood, Melissa

    2015-06-01

    Educational opportunities for professionals working with children requiring palliative care are central to future development within the specialty across countries. International educational initiatives involving a range of professionals are important for learning with and from others working within the field. To explore the experiences and value to students from participating in an international online discussion forum. This article examines one such initiative; the use of an international asynchronous discussion forum with students in Melbourne, Australia and Belfast, UK who work with children and families. The innovation is examined and student perspectives of the forum's value are presented. Students endorsed the value of the forum, identifying three main areas of learning: differences across locations within countries, respecting different views and being open, and need for continued learning within children's palliative care. The overarching theme 'we are not alone' supported the idea that participation in the international discussion forum enabled students to see a broader perspective. Ideas for future developments of similar forums are also explored.

  14. Rapid Diagnosis of Rhabdomyolysis with Point-of-Care Ultrasound.

    Science.gov (United States)

    Nassar, Alicia; Talbot, Richard; Grant, Ashley; Derr, Charlotte

    2016-11-01

    It is important to rapidly diagnosis and treat rhabdomyolysis in order to decrease morbidity and mortality. To date there are no reports in the emergency medicine literature on the use of point-of-care ultrasound in the diagnosis of rhabdomyolysis. This unique case describes how ultrasound was used in the emergency department (ED) to quickly diagnose and treat rhabdomyolysis prior to confirmation with an elevated serum creatine kinase. When coupled with a high index of suspicion, ultrasound can be one of the most portable, readily available, low cost, and minimally invasive techniques for making a rapid diagnosis of rhabdomyolysis in the ED.

  15. Service Quality of Delivered Care from the Perception of Women with Caesarean Section and Normal Delivery

    Directory of Open Access Journals (Sweden)

    Jafar S. Tabrizi

    2014-12-01

    Full Text Available Background: Our aim was to determine the service quality of delivered care for people with Caesarean Section and Normal Delivery. Methods: A cross-sectional study was conducted among 200 people who had caesarean section and normal delivery in Al-Zahra Teaching Hospital in Tabriz, north western Iran. Service quality was calculated using: Service Quality = 10 – (Importance × Performance based on importance and performance of service quality aspects from the postpartum women‟s perspective.A hierarchical regression analysis was applied in two steps using the enter method to examine the associations between demographics and SQ scores. Data were analysed using the SPSS-17 software. Results: “Confidentiality”, “autonomy”, “choice of care provider” and “communication” achieved scores at the highest level of quality; and “support group”, “prompt attention”, “prevention and early detection”, “continuity of care”, “dignity”, “safety”, “accessibility and “basic amenities” got service quality score less than eight. Statistically significant relationship was found between service quality score and continuity of care (P=0.008. Conclusion: A notable gap between the participants‟ expectations and what they have actually received in most aspects of provided care. So, there is an opportunityto improve the quality of delivered care.

  16. Smartphone based point-of-care detector of urine albumin

    Science.gov (United States)

    Cmiel, Vratislav; Svoboda, Ondrej; Koscova, Pavlina; Provaznik, Ivo

    2016-03-01

    Albumin plays an important role in human body. Its changed level in urine may indicate serious kidney disorders. We present a new point-of-care solution for sensitive detection of urine albumin - the miniature optical adapter for iPhone with in-built optical filters and a sample slot. The adapter exploits smart-phone flash to generate excitation light and camera to measure the level of emitted light. Albumin Blue 580 is used as albumin reagent. The proposed light-weight adapter can be produced at low cost using a 3D printer. Thus, the miniaturized detector is easy to use out of lab.

  17. Constraints on Stress Components at the Internal Singular Point of an Elastic Compound Structure

    Science.gov (United States)

    Pestrenin, V. M.; Pestrenina, I. V.

    2017-03-01

    The classical analytical and numerical methods for investigating the stress-strain state (SSS) in the vicinity of a singular point consider the point as a mathematical one (having no linear dimensions). The reliability of the solution obtained by such methods is valid only outside a small vicinity of the singular point, because the macroscopic equations become incorrect and microscopic ones have to be used to describe the SSS in this vicinity. Also, it is impossible to set constraint or to formulate solutions in stress-strain terms for a mathematical point. These problems do not arise if the singular point is identified with the representative volume of material of the structure studied. In authors' opinion, this approach is consistent with the postulates of continuum mechanics. In this case, the formulation of constraints at a singular point and their investigation becomes an independent problem of mechanics for bodies with singularities. This method was used to explore constraints at an internal singular point (representative volume) of a compound wedge and a compound rib. It is shown that, in addition to the constraints given in the classical approach, there are also constraints depending on the macroscopic parameters of constituent materials. These constraints turn the problems of deformable bodies with an internal singular point into nonclassical ones. Combinations of material parameters determine the number of additional constraints and the critical stress state at the singular point. Results of this research can be used in the mechanics of composite materials and fracture mechanics and in studying stress concentrations in composite structural elements.

  18. Optoelectronic Capillary Sensors in Microfluidic and Point-of-Care Instrumentation

    Directory of Open Access Journals (Sweden)

    Michał Borecki

    2010-04-01

    Full Text Available This paper presents a review, based on the published literature and on the authors’ own research, of the current state of the art of fiber-optic capillary sensors and related instrumentation as well as their applications, with special emphasis on point-of-care chemical and biochemical sensors, systematizing the various types of sensors from the point of view of the principles of their construction and operation. Unlike classical fiber-optic sensors which rely on changes in light propagation inside the fiber as affected by outside conditions, optical capillary sensors rely on changes of light transmission in capillaries filled with the analyzed liquid, which opens the possibility of interesting new applications, while raising specific issues relating to the construction, materials and instrumentation of those sensors.

  19. [Guidelines for the management of point-of care testing nonconformities according to the EN ISO 22870].

    Science.gov (United States)

    Houlbert, C; Annaix, V; Szymanowicz, A; Vassault, A; Guimont, M C; Pernet, P

    2012-02-01

    In this paper, guidelines are proposed to fulfill the requirements of EN ISO 22870 standard regarding the management of point-of-care testing (POCT) nonconformities. In the first part, the main nonconformities that may affect POCT are given, the means for resolution and the control of adverse events are proposed. In the second part, we propose recommendations in case of unavailability of a point-of-care testing device from the occurring of the adverse event, to the restarting of the device.

  20. NT-proBNP on Cobas h 232 in point-of-care testing

    DEFF Research Database (Denmark)

    Gils, Charlotte; Ramanathan, R.; Breindahl, T.

    2015-01-01

    Background. NT-proBNP may be useful for ruling out heart failure in primary health care. In this study we examined the analytical quality of NT-proBNP in primary health care on the Cobas h 232 point-of-care instrument compared with measurements performed in a hospital laboratory. Materials...... and methods. Blood samples requested for NT-proBNP were collected in primary health care (n = 95) and in a hospital laboratory (n = 107). NT-proBNP was measured on-site on Cobas h 232 instruments both in primary health care centres and at the hospital laboratory and all samples were also analyzed...... with a comparison method at the hospital. Precision, trueness, accuracy, and lot-variation were determined at different concentration levels and evaluated according to acceptance criteria. Furthermore user-friendliness was assessed by questionnaires. Results. For Cobas h 232 repeatability CV was 8...

  1. Safety Culture to Prevent Infection in Normal Birth Care by Village Midwives Ateast Lombok Nusa Tenggara Barat

    OpenAIRE

    Bartini, Istri

    2015-01-01

    Background: Normal birth care is one of midwife's competence within the most of risks to both women and midwife. Limited of health facilities and social culture are major problem of midwifery care. In fact, infection cases have been occurring and become a significant cause in maternal death. At East Lombok most of 93,33% birth was provided by midwife. It was a tricky to explain that midwife does not work as well.Aim: to describe safety culture to prevent infection during normal birth care at ...

  2. Ultra low-cost, portable smartphone optosensors for mobile point-of-care diagnostics

    Science.gov (United States)

    Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei

    2018-02-01

    Smartphone optosensors with integrated optical components make mobile point-of-care (MPoC) diagnostics be done near patients' side. It'll especially have a significant impact on healthcare delivery in rural or remote areas. Current FDA-approved PoC devices achieving clinical level are still at high cost and not affordable in rural hospitals. We present a series of ultra low-cost smartphone optical sensing devices for mobile point-of-care diagnosis. Aiming different targeting analytes and sensing mechanisms, we developed custom required optical components for each smartphone optosensros. These optical devices include spectrum readers, colorimetric readers for microplate, lateral flow device readers, and chemiluminescence readers. By integrating our unique designed optical components into smartphone optosening platform, the anlaytes can be precisely detected. Clinical testing results show the clinical usability of our smartphone optosensors. Ultra low-cost portable smartphone optosensors are affordable for rural/remote doctors.

  3. Point-of-care testing in an organ procurement organization donor management setting.

    Science.gov (United States)

    Baier, K A; Markham, L E; Flaigle, S P; Nelson, P W; Shield, C F; Muruve, N A; Aeder, M I; Murillo, D; Bryan, C F

    2003-01-01

    Our organ procurement organization (OPO) evaluated the clinical and financial efficacy of point-of-care testing (POCT) in management of our deceased organ donors. Before we implemented point-of care testing with the i-STAT into routine clinical donor management, we compared the i-STAT result with the result from the respective donor hospital lab (DHL) for certain analytes on 15 consecutive donors in our OPO from 26 March to 14 May 2001. The financial impact was studied by reviewing 77 donors from July 2001 to March 2002. There was a strong correlation for each analyte between the POC and DHL test results with r-values as follows: pH 0.86; PCO2 = 0.96; PO2 = 0.98; sodium = 0.98; potassium = 0.95; chloride = 0.94; BUN = 0.98; glucose = 0.92; haematocrit = 0.87 and creatinine = 0.95. Since our OPO coordinators began using i-STAT in their routine clinical management of organ donors, they can now more quickly maximize oxygenation and fluid management of the donor and make extra-renal placement calls sooner. Finally, since we are no longer being billed for the testing performed on the i-STAT, average financial savings to our OPO are US dollars 733 per case. Point-of-care testing in management of our OPO donors provides a result that is equivalent to that of the donor hospital lab, has quicker turn-around time than the donor hospital laboratory, allowing more immediate clinical management decisions to be made so that extra-renal offers may begin sooner.

  4. Anesthesiology Point of Care project.

    Science.gov (United States)

    McDonald, John S; Noback, Carl R; Cheng, Drew; Lee, T K; Nenov, Val

    2002-01-01

    We are developing a dynamic prototype visual communication system for the operating room environs. This has classically been viewed as an isolated and impenetrable workplace. All medical experiences and all teaching remain in a one to one closed loop with no recall or subsequent sharing for the training and education of other colleagues. The "Anesthesia Point of Care" (APOC) concept embraces the sharing of, recording of, and presentation of various physiological and pharmacological events so that real time memory can be shared at a later time for the edification of other colleagues who were not present at the time of the primary learning event. In addition it also provides a remarkably rapid tool for fellow faculty to respond to obvious stress and crisis events that can be broadcast instantly at the time of happening. Finally, it also serves as an efficient and effective means of paging and general communication throughout the daily routines among various healthcare providers in anesthesiology who work as a team unit; these include the staff, residents, CRNAs, physician assistants, and technicians. This system offers a unique opportunity to eventually develop future advanced ideas that can include training exercises, presurgical evaluations, surgical scheduling and improvements in efficiency based upon earlier than expected case completion or conversely later than expected case completion and even as a unique window to development of improved billing itemization and coordination.

  5. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    Science.gov (United States)

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Cancer Survivorship Care Plan Utilization and Impact on Clinical Decision-Making at Point-of-Care Visits with Primary Care: Results from an Engineering, Primary Care, and Oncology Collaborative for Survivorship Health.

    Science.gov (United States)

    Donohue, SarahMaria; Haine, James E; Li, Zhanhai; Feldstein, David A; Micek, Mark; Trowbridge, Elizabeth R; Kamnetz, Sandra A; Sosman, James M; Wilke, Lee G; Sesto, Mary E; Tevaarwerk, Amye J

    2017-11-02

    Every cancer survivor and his/her primary care provider should receive an individualized survivorship care plan (SCP) following curative treatment. Little is known regarding point-of-care utilization at primary care visits. We assessed SCP utilization in the clinical context of primary care visits. Primary care physicians and advanced practice providers (APPs) who had seen survivors following provision of an SCP were identified. Eligible primary care physicians and APPs were sent an online survey, evaluating SCP utilization and influence on decision-making at the point-of-care, accompanied by copies of the survivor's SCP and the clinic note. Eighty-eight primary care physicians and APPs were surveyed November 2016, with 40 (45%) responding. Most respondents (60%) reported discussing cancer or related issues during the visit. Information needed included treatment (66%) and follow-up visits, and the cancer team was responsible for (58%) vs primary care (58%). Respondents acquired this information by asking the patient (79%), checking oncology notes (75%), the SCP (17%), or online resources (8%). Barriers to SCP use included being unaware of the SCP (73%), difficulty locating it (30%), and finding needed information faster via another mechanism (15%). Despite largely not using the SCP for the visit (90%), most respondents (61%) believed one would be quite or very helpful for future visits. Most primary care visits included discussion of cancer or cancer-related issues. SCPs may provide the information necessary to deliver optimal survivor care but efforts are needed to reduce barriers and design SCPs for primary care use.

  7. Rapid Diagnosis of Rhabdomyolysis with Point-of-Care Ultrasound

    Directory of Open Access Journals (Sweden)

    Alicia Nassar

    2016-11-01

    Full Text Available It is important to rapidly diagnosis and treat rhabdomyolysis in order to decrease morbidity and mortality. To date there are no reports in the emergency medicine literature on the use of point-of-care ultrasound in the diagnosis of rhabdomyolysis. This unique case describes how ultrasound was used in the emergency department (ED to quickly diagnose and treat rhabdomyolysis prior to confirmation with an elevated serum creatine kinase. When coupled with a high index of suspicion, ultrasound can be one of the most portable, readily available, low cost, and minimally invasive techniques for making a rapid diagnosis of rhabdomyolysis in the ED.

  8. Evidence-based point-of-care tests and device designs for disaster preparedness.

    Science.gov (United States)

    Brock, T Keith; Mecozzi, Daniel M; Sumner, Stephanie; Kost, Gerald J

    2010-01-01

    To define pathogen tests and device specifications needed for emerging point-of-care (POC) technologies used in disasters. Surveys included multiple-choice and ranking questions. Multiple-choice questions were analyzed with the chi2 test for goodness-of-fit and the binomial distribution test. Rankings were scored and compared using analysis of variance and Tukey's multiple comparison test. Disaster care experts on the editorial boards of the American Journal of Disaster Medicine and the Disaster Medicine and Public Health Preparedness, and the readers of the POC Journal. Vibrio cholera and Staphylococcus aureus were top-ranked pathogens for testing in disaster settings. Respondents felt that disaster response teams should be equipped with pandemic infectious disease tests for novel 2009 H1N1 and avian H5N1 influenza (disaster care, p disaster settings, respondents preferred self-contained test cassettes (disaster care, p disaster care, p disaster care scenarios, in which Vibrio cholera, methicillin-sensitive and methicillin-resistant Staphylococcus aureus, and Escherichia coli ranked the highest. POC testing should incorporate setting-specific design criteria such as safe disposable cassettes and direct blood sampling at the site of care.

  9. Traumatic Fetal Intracranial Hemorrhage Suggested by Point-of-Care Ultrasound

    Directory of Open Access Journals (Sweden)

    Lei Wu

    2018-01-01

    Full Text Available While the use of ultrasound to diagnose a fetal intracranial hemorrhage in utero is not a new concept, the emphasis of point-of-care ultrasound (POCUS at the initial trauma presentation of the mother to evaluate for fetal injury is novel. A review of the literature failed to reveal a single case report wherein POCUS in the workup of a pregnant trauma patient led to the diagnosis of fetal intracranial hemorrhage. This is such a case.

  10. Emerging technologies in point-of-care molecular diagnostics for resource-limited settings.

    Science.gov (United States)

    Peeling, Rosanna W; McNerney, Ruth

    2014-06-01

    Emerging molecular technologies to diagnose infectious diseases at the point at which care is delivered have the potential to save many lives in developing countries where access to laboratories is poor. Molecular tests are needed to improve the specificity of syndromic management, monitor progress towards disease elimination and screen for asymptomatic infections with the goal of interrupting disease transmission and preventing long-term sequelae. In simplifying laboratory-based molecular assays for use at point-of-care, there are inevitable compromises between cost, ease of use and test performance. Despite significant technological advances, many challenges remain for the development of molecular diagnostics for resource-limited settings. There needs to be more advocacy for these technologies to be applied to infectious diseases, increased efforts to lower the barriers to market entry through streamlined and harmonized regulatory approaches, faster policy development for adoption of new technologies and novel financing mechanisms to enable countries to scale up implementation.

  11. [Participation as Target of Social Medicine and Nursing Care: - Legal Definition of Long-Term Care Dependency - Strategies to Prevent Long-Term Care Dependency].

    Science.gov (United States)

    Nüchtern, Elisabeth; Gansweid, Barbara; Gerber, Hans; von Mittelstaedt, Gert

    2017-01-01

    Objective: By the "Second Bill to Strengthen Long-Term Care", a new concept of long-term care dependency will be introduced, valid from 2017. Long-term care dependency according to Social Code XI will be defined covering more aspects than today. Therefore, the working group "Nursing Care" of the division "Social Medicine in Practice and Rehabilitation" in the German Society for Social Medicine and Prevention presents their results after working on the social medicine perspective of the definition and prevention of long-term care dependency. Methods: Both the definition and strategies to prevent long-term care dependency are systematically taken into consideration from the point of view of social medicine on the basis of the International Classification of Functioning, Disability and Health (ICF), as long-term care dependency means a defined condition of disability. Results: Both the current and the new concept of long-term care dependency focus activity limitations. The perspective of social medicine considers the interactions of health condition, its effects on daily activities and personal as well as environmental factors. From this point of view approaches for social benefits concerning prevention and rehabilitation can be identified systematically so as to work against the development and progression of long-term care dependency. The reference to the ICF can facilitate the communication between different professions. The new "graduation" of long-term care dependency would allow an international "translation" referring to the ICF. Conclusion: Experts from the field of social medicine as well as those of nursing care, care-givers and nursing researchers have in common the objective that persons in need of nursing care can participate in as many aspects of life of importance to them in an autonomous and self-determined way. The point of view of social medicine on long-term care dependency is fundamental for all occupational groups that are involved and for their

  12. Accuracy of three hemoglobin A1c point-of-care systems for glucose monitoring in patients with diabetes mellitus.

    Science.gov (United States)

    Torregrosa, María-Eugenia; Molina, Juan; Argente, Carlos R; Ena, Javier

    2015-12-01

    Use of hemoglobin A1c point-of-care devices in physician offices provides immediate results and reduces inconveniences for the patients. We compared the analytical performances of 3 point-of-care HbA1c analyzers to high pressure liquid chromatography (HPLC). We preselected a pool of 40 EDTA-preserved whole blood samples from our laboratory with HbA1c results obtained by HPLC (mean 6.6% [49 mmol/mol] and range: 4.6-9.9% [27-87 mmol/mol]). Aliquots of theses samples were tested by Afinion AS100, DCA Vantage and In2it point-of-care systems. According the Clinical Laboratory Standards Institute EP-09 protocol we determined linearity (linear regression and correlation coefficient between point-of-care and reference methods), bias (Bland-Altman analysis) and coefficient of variation (%). We used the acceptability criteria endorsed by the National Glycohemoglobin Standardization Program. The calculated correlation coefficients (r) were 0.98, 0.98 and 0.83 for Afinion AS100, DCA Vantage and In2it systems, respectively. The 95% confidence interval of the error between point-of-care systems and the reference method was -0.41% and +0.34% (p =.22) for Afinion AS100, -0.62% and +0.05% (p =.57) for DCA Vantage, and -1.15% and +1.26% (p<.001) for the In2it. The coefficients of variation for Afinion AS100, DCA Vantage and In2it systems were 1.80, 3.74 and 7.14%, respectively. Only the Afinion AS100 point-of-care system met all NGSP performance criteria. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  13. News and Perspectives on Treatment of Normal Pressure Internal Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Cristian Năstase

    2014-06-01

    Full Text Available Many patients, usually over 60 years old, presenting presenile dementia associated with marked gait disorders, impaired balance, urinary incontinence, have been shown to have enlarged ventricles associated with relatively small cortical atrophy. Intracranial pressure monitoring indicates normal values, or subject to only minor peaks, usually at night. Because some of these patients improve markedly after ventricular shunting procedures it has been suggested that their neurological dysfunction may be caused by a pressure effect on the brain from the increased internal surface of the ventricles. Many of these patients do benefit from surgery, and a lot of them have a history of subarachnoid hemorrhage, traumatic brain injury or meningitis which might have impaired the CSF absorption.

  14. Second Annual Meeting of the International Society of Pediatric Wound Care.

    Science.gov (United States)

    Keswani, Sundeep G

    2015-10-01

    The overarching goals of the International Society of Pediatric Wound Care (ISPeW) are to (1) set global standards for the assessment and treatment of pediatric wounds of varying etiologies; (2) provide a forum for international interprofessional collaboration among healthcare professionals, researchers, educators, and industry leaders dedicated to the care of pediatric wounds; (3) promote and support clinical research focused on the prevention, assessment, and treatment of pediatric wounds; (4) collaborate with wound care organizations worldwide on pediatric wound care issues; and (5) provide evidence-based pediatric wound care education to healthcare professionals, parents, and lay caregivers. This edition of Advances in Wound Care includes some of the work that was presented at the 2014 ISPeW meeting in Rome. The first article by Dr. Romanelli, is an in-depth description of the progression of skin physiology throughout its maturational stages and clinical implication. A cutting edge article by Dr. Timothy King then follows, with regard to scar prevention in postnatal tissues. This is followed by a comprehensive look at debridement techniques in pediatric trauma by Dr. Ankush Gosain. Next, is a cautionary article by Dr. Luca Spazzapan that examines the prevalence of diabetic foot ulcers in children and the potential for an epidemic. The last article in this series is from the keynote speaker, Dr. Amit Geffen, who eloquently examines the use of biomaterials to offload and prevent pediatric pressure ulcers.

  15. Optimal approaches to the health economics of palliative care: report of an international think tank.

    Science.gov (United States)

    Gomes, Barbara; Harding, Richard; Foley, Kathleen M; Higginson, Irene J

    2009-07-01

    More people will need palliative care in aging societies with stretched health budgets and less ability to provide informal care. The future will bring new and tougher challenges to sustain, optimize, and expand the 8000 dedicated palliative care services that currently exist in the world. The full breakdown of the costs of palliative care is yet to be unveiled, and this has left huge unresolved questions for funding, costing, evaluating, and modeling palliative care. At an international meeting in London in November 2007, a group of 40 researchers, health economists, policy makers, and advocates exchanged their experiences, concerns, and recommendations in five main areas: shared definitions, strengths and weaknesses of different payment systems, international and country-specific research challenges, appropriate economic evaluation methods, and the varied perspectives to the costs of palliative care. This article reports the discussions that took place and the views of this international group of experts on the best research approaches to capture, analyze, and interpret data on both costs and outcomes for families and patients toward the end of life.

  16. Expanding the Operational Limits of the Single-Point Impedance Diagnostic for Internal Temperature Monitoring of Lithium-ion Batteries

    International Nuclear Information System (INIS)

    Spinner, Neil S.; Love, Corey T.; Rose-Pehrsson, Susan L.; Tuttle, Steven G.

    2015-01-01

    Highlights: • Single-point impedance diagnostic technique demonstrated for lithium-ion batteries • Correlation between imaginary impedance and internal temperature determined • Instantaneous monitoring of commercial lithium-ion battery internal temperature • Expanded temperature range from −10°C up to 95°C • Non-invasive method useful for practical temperature monitoring of commercial cells - Abstract: Instantaneous internal temperature monitoring of a commercial 18650 LiCoO 2 lithium-ion battery was performed using a single-point EIS measurement. A correlation between the imaginary impedance, –Z imag , and internal temperature at 300 Hz was developed that was independent of the battery’s state of charge. An Arrhenius-type dependence was applied, and the activation energy for SEI ionic conductivity was found to be 0.13 eV. Two separate temperature-time experiments were conducted with different sequences of temperature, and single-point impedance tests at 300 Hz were performed to validate the correlation. Limitations were observed with the upper temperature range (68°C < T < 95°C), and consequently a secondary, empirical fit was applied for this upper range to improve accuracy. Average differences between actual and fit temperatures decreased around 3-7°C for the upper range with the secondary correlation. The impedance response at this frequency corresponded to the anode/SEI layer, and the SEI is reported to be thermally stable up to around 100°C, at which point decomposition may occur leading to battery deactivation and/or total failure. It is therefore of great importance to be able to track internal battery temperatures up to this critical point of 100°C, and this work demonstrates an expansion of the single-point EIS diagnostic to these elevated temperatures

  17. 3rd International Conference on Health Care Systems Engineering

    CERN Document Server

    Li, Jingshan; Matta, Andrea; Sahin, Evren; Vandaele, Nico; Visintin, Filippo

    2017-01-01

    This book presents statistical processes for health care delivery and covers new ideas, methods and technologies used to improve health care organizations. It gathers the proceedings of the Third International Conference on Health Care Systems Engineering (HCSE 2017), which took place in Florence, Italy from May 29 to 31, 2017. The Conference provided a timely opportunity to address operations research and operations management issues in health care delivery systems. Scientists and practitioners discussed new ideas, methods and technologies for improving the operations of health care systems, developed in close collaborations with clinicians. The topics cover a broad spectrum of concrete problems that pose challenges for researchers and practitioners alike: hospital drug logistics, operating theatre management, home care services, modeling, simulation, process mining and data mining in patient care and health care organizations.

  18. Correlation between patients' reasons for encounters/health problems and population density in Japan: a systematic review of observational studies coded by the International Classification of Health Problems in Primary Care (ICHPPC) and the International Classification of Primary care (ICPC).

    Science.gov (United States)

    Kaneko, Makoto; Ohta, Ryuichi; Nago, Naoki; Fukushi, Motoharu; Matsushima, Masato

    2017-09-13

    The Japanese health care system has yet to establish structured training for primary care physicians; therefore, physicians who received an internal medicine based training program continue to play a principal role in the primary care setting. To promote the development of a more efficient primary health care system, the assessment of its current status in regard to the spectrum of patients' reasons for encounters (RFEs) and health problems is an important step. Recognizing the proportions of patients' RFEs and health problems, which are not generally covered by an internist, can provide valuable information to promote the development of a primary care physician-centered system. We conducted a systematic review in which we searched six databases (PubMed, the Cochrane Library, Google Scholar, Ichushi-Web, JDreamIII and CiNii) for observational studies in Japan coded by International Classification of Health Problems in Primary Care (ICHPPC) and International Classification of Primary Care (ICPC) up to March 2015. We employed population density as index of accessibility. We calculated Spearman's rank correlation coefficient to examine the correlation between the proportion of "non-internal medicine-related" RFEs and health problems in each study area in consideration of the population density. We found 17 studies with diverse designs and settings. Among these studies, "non-internal medicine-related" RFEs, which was not thought to be covered by internists, ranged from about 4% to 40%. In addition, "non-internal medicine-related" health problems ranged from about 10% to 40%. However, no significant correlation was found between population density and the proportion of "non-internal medicine-related" RFEs and health problems. This is the first systematic review on RFEs and health problems coded by ICHPPC and ICPC undertaken to reveal the diversity of health problems in Japanese primary care. These results suggest that primary care physicians in some rural areas of Japan

  19. Accuracy of Handheld Point-of-Care Fingertip Lactate Measurement in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Gaieski, David G

    2013-02-01

    Full Text Available Introduction: Early recognition of elevated lactate levels in sepsis may hasten the detection of those patients eligible for aggressive resuscitation. Point-of-care (POC testing is now increasingly available for use in the emergency department (ED. We examined the accuracy and time-saving effect of a handheld POC device for the measurement of fingertip and whole blood lactate as compared with reference laboratory testing in critically ill ED patients.Methods: A convenience sample of adult ED patients receiving serum lactate testing was prospectively enrolled at an urban, tertiary care US hospital. Consenting patients underwent fingertip POC lactate measurement with a portable device and simultaneous whole blood sampling for analysis by both the POC device and standard laboratory analyzer (‘‘reference method’’. Lactate measurements were compared by intraclass correlation (ICC and Bland and Altman plots. Differences in time to test result were compared by paired t test.Results: Twenty-four patients, 19 (79% with sepsis and 21 (88% with lactate levels below 4 mmol/L, were included from April 2005 to May 2005. Fingertip POC and whole blood POC lactate measurements each correlated tightly with the reference method (ICC ¼ 0.90 and ICC ¼ 0.92, respectively. Mean time between obtaining fingertip lactate samples and whole blood reference lactate samples was 8 6 13 minutes. Mean time between obtaining POC and reference laboratory lactate results was 65 minutes (95% confidence interval, 30–103.Conclusion: Fingertip POC lactate measurement is an accurate method to determine lactate levels in infected ED patients with normal or modestly elevated lactate values and significantly decreases time to test results. These findings should be verified in a larger, more critically ill, ED population. [West J Emerg Med. 2013;14(1:58-62.

  20. Portable Amplifier Design for a Novel EEG Monitor in Point-of-Care Applications.

    Science.gov (United States)

    Luan, Bo; Sun, Mingui; Jia, Wenyan

    2012-01-01

    The Electroencephalography (EEG) is a common diagnostic tool for neurological diseases and dysfunctions, such as epilepsy and insomnia. However, the current EEG technology cannot be utilized quickly and conveniently at the point of care due to the complex skin preparation procedures required and the inconvenient EEG data acquisition systems. This work presents a portable amplifier design that integrates a set of skin screw electrodes and a wireless data link. The battery-operated amplifier contains an instrumentation amplifier, two noninverting amplifiers, two high-pass filters, and a low-pass filter. It is able to magnify the EEG signals over 10,000 times and has a high impedance, low noise, small size and low weight. Our electrode and amplifier are ideal for point-of-care applications, especially during transportation of patients suffering from traumatic brain injury or stroke.

  1. PHP47 - Early assessment of highly innovative medical technology: clinical and economical gains of point-of-care applications for measuring potassium concentrations

    NARCIS (Netherlands)

    van de Wetering, G.; Hummel, J. Marjan; van Montfort, Augustinus P.W.P.; Montfoort, A.; IJzerman, Maarten Joost

    2009-01-01

    OBJECTIVES: Innovative point-of-care diagnostics are likely to be having a strong impact on health care. The aim of this study is to conduct an early assessment of point-of-care chips. These chips can detect many particles and, consequently, many product-market combinations can be developed. This

  2. Performance evaluation of the microINR® point-of-care INR-testing system.

    Science.gov (United States)

    Joubert, J; van Zyl, M C; Raubenheimer, J

    2018-04-01

    Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.

  3. [New image of home nursing created by point of care testing (POCT) - examination of issues in the introduction of POCT].

    Science.gov (United States)

    Hata, Kiyomi

    2014-12-01

    With the rising number of patients who rely on medical care, it is necessary to use evolving health care technology appropriately, to control health care costs, and to enhance the well-being of patients in the home care setting. Point of care testing (POCT)is instrumental system for such demands for home care; however, this term remains relatively unknown in Japan. For this research, I conducted a qualitative analysis of factors based on stories obtained through group interviews of 11 experienced home visiting nurses who work at three home-visit nursing stations for the purpose of clarifying issues in the introduction of POCT. The results of the research identified five categories and 16 subcategories for issues in the introduction of POCT. The identified categories are expected to be useful for the spread of POCT in the future. Key words: Point of care testing, Home care nursing.

  4. Integrated care in an international perspective: EUPHA proceedings December 2001.

    NARCIS (Netherlands)

    Delnoij, D.; Klazinga, N.; Kulu Glasgow, I.

    2002-01-01

    The workshop of the EUPHA section Health Services Research took place on Thursday, December 8th, 2001 in Brussels at the annual conference of the EUPHA (European Public Health Association). The theme of the workshop was integrated care in an international perspective. Integrated care can be defined

  5. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection

    Directory of Open Access Journals (Sweden)

    Han Yih Lau

    2017-12-01

    Full Text Available Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail.

  6. Barriers to Point-of-Care Testing in India: Results from Qualitative Research across Different Settings, Users and Major Diseases

    Science.gov (United States)

    Engel, Nora; Ganesh, Gayatri; Patil, Mamata; Yellappa, Vijayashree; Pant Pai, Nitika; Vadnais, Caroline; Pai, Madhukar

    2015-01-01

    Background Successful point-of-care testing, namely ensuring the completion of the test and treat cycle in the same encounter, has immense potential to reduce diagnostic and treatment delays, and impact patient outcomes. However, having rapid tests is not enough, as many barriers may prevent their successful implementation in point-of-care testing programs. Qualitative research on diagnostic practices may help identify such barriers across different points of care in health systems. Methods In this exploratory qualitative study, we conducted 78 semi-structured interviews and 13 focus group discussions in an urban and rural area of Karnataka, India, with healthcare providers (doctors, nurses, specialists, traditional healers, and informal providers), patients, community health workers, test manufacturers, laboratory technicians, program managers and policy-makers. Participants were purposively sampled to represent settings of hospitals, peripheral labs, clinics, communities and homes, in both the public and private sectors. Results In the Indian context, the onus is on the patient to ensure successful point-of-care testing across homes, clinics, labs and hospitals, amidst uncoordinated providers with divergent and often competing practices, in settings lacking material, money and human resources. We identified three overarching themes affecting point-of-care testing: the main theme is ‘relationships’ among providers and between providers and patients, influenced by the cross-cutting theme of ‘infrastructure’. Challenges with both result in ‘modified practices’ often favouring empirical (symptomatic) treatment over treatment guided by testing. Conclusions Even if tests can be conducted on the spot and infrastructure challenges have been resolved, relationships among providers and between patients and providers are crucial for successful point-of-care testing. Furthermore, these barriers do not act in isolation, but are interlinked and need to be examined

  7. Barriers to Point-of-Care Testing in India: Results from Qualitative Research across Different Settings, Users and Major Diseases.

    Directory of Open Access Journals (Sweden)

    Nora Engel

    Full Text Available Successful point-of-care testing, namely ensuring the completion of the test and treat cycle in the same encounter, has immense potential to reduce diagnostic and treatment delays, and impact patient outcomes. However, having rapid tests is not enough, as many barriers may prevent their successful implementation in point-of-care testing programs. Qualitative research on diagnostic practices may help identify such barriers across different points of care in health systems.In this exploratory qualitative study, we conducted 78 semi-structured interviews and 13 focus group discussions in an urban and rural area of Karnataka, India, with healthcare providers (doctors, nurses, specialists, traditional healers, and informal providers, patients, community health workers, test manufacturers, laboratory technicians, program managers and policy-makers. Participants were purposively sampled to represent settings of hospitals, peripheral labs, clinics, communities and homes, in both the public and private sectors.In the Indian context, the onus is on the patient to ensure successful point-of-care testing across homes, clinics, labs and hospitals, amidst uncoordinated providers with divergent and often competing practices, in settings lacking material, money and human resources. We identified three overarching themes affecting point-of-care testing: the main theme is 'relationships' among providers and between providers and patients, influenced by the cross-cutting theme of 'infrastructure'. Challenges with both result in 'modified practices' often favouring empirical (symptomatic treatment over treatment guided by testing.Even if tests can be conducted on the spot and infrastructure challenges have been resolved, relationships among providers and between patients and providers are crucial for successful point-of-care testing. Furthermore, these barriers do not act in isolation, but are interlinked and need to be examined as such. Also, a test alone has only

  8. The clinical situation of point-of-care testing and its future development at the emergency department in Shanghai.

    Science.gov (United States)

    Leong, Waiian; Chen, Lianxiang; Yu, Ping; Wei, Bohua; Wang, Cuicui; Ying, Yilin; Jiang, Jie; Tong, Jianjing; Zhu, Dingliang; Ye, Jing; Lu, Yiming

    2014-12-01

    We assessed the efficiency of point-of-care (POC) tests in the emergency department (ED) by comparing them with the international standard. We recorded the turnaround times (TATs) for processing laboratory biomarkers to assess laboratory efficiency from 17 EDs in national/regional hospitals. We also compared patient components between national and regional hospitals. Although the 17 enrolled hospitals expanded their EDs, they contained only five POC machines among them. The P50 (P25, P75) of the TATs for POC tests was 47 min (39, 55.5 min) for cardiac troponin T, which was much longer than the international standard (30 min). The TATs of other cardiac biomarkers were also longer than 30 min. The low efficiency of TATs for POC tests was a common feature in both regional and national hospitals (p > 0.05). Myocardial infarction was diagnosed in 61% of investigated ED patients who visited national hospitals, which is more frequently than those diagnosed at regional hospitals (46%, p administrative management of EDs. This issue should be addressed in the next version of the medical reform policy. © 2014 Society for Laboratory Automation and Screening.

  9. Point-of-care echocardiography in simulation-based education and assessment.

    Science.gov (United States)

    Amini, Richard; Stolz, Lori A; Javedani, Parisa P; Gaskin, Kevin; Baker, Nicola; Ng, Vivienne; Adhikari, Srikar

    2016-01-01

    Emergency medicine milestones released by the Accreditation Council for Graduate Medical Education require residents to demonstrate competency in bedside ultrasound (US). The acquisition of these skills necessitates a combination of exposure to clinical pathology, hands-on US training, and feedback. We describe a novel simulation-based educational and assessment tool designed to evaluate emergency medicine residents' competency in point-of-care echocardiography for evaluation of a hypotensive patient with chest pain using bedside US. This was a cross-sectional study conducted at an academic medical center. A simulation-based module was developed to teach and assess the use of point-of-care echocardiography in the evaluation of the hypotensive patient. The focus of this module was sonographic imaging of cardiac pathology, and this focus was incorporated in all components of the session: asynchronous learning, didactic lecture, case-based learning, and hands-on stations. A total of 52 residents with varying US experience participated in this study. Questions focused on knowledge assessment demonstrated improvement across the postgraduate year (PGY) of training. Objective standardized clinical examination evaluation demonstrated improvement between PGY I and PGY III; however, it was noted that there was a small dip in hands-on scanning skills during the PGY II. Clinical diagnosis and management skills also demonstrated incremental improvement across the PGY of training. The 1-day, simulation-based US workshop was an effective educational and assessment tool at our institution.

  10. Experiences of registered nurses with regard to accessing health information at the point-of-care via mobile computing devices

    Directory of Open Access Journals (Sweden)

    Esmeralda Ricks

    2015-11-01

    Full Text Available Background: The volume of health information necessary to provide competent health care today has become overwhelming. Mobile computing devices are fast becoming an essential clinical tool for accessing health information at the point-of-care of patients. Objectives: This study explored and described how registered nurses experienced accessing information at the point-of-care via mobile computing devices (MCDs. Method: A qualitative, exploratory, descriptive and contextual design was used. Ten in–depth interviews were conducted with purposively sampled registered nurses employed by a state hospital in the Nelson Mandela Bay Municipality (NMBM. Interviews were recorded, transcribed verbatim and analysed using Tesch’s data analysis technique. Ethical principles were adhered to throughout the study. Guba’s model of trustworthiness was used to confirm integrity of the study. Results: Four themes emerged which revealed that the registered nurses benefited from the training they received by enabling them to develop, and improve, their computer literacy levels. Emphasis was placed on the benefits that the accessed information had for educational purposes for patients and the public, for colleagues and students. Furthermore the ability to access information at the point-of-care was considered by registered nurses as valuable to improve patient care because of the wide range of accurate and readily accessible information available via the mobile computing device. Conclusion: The registered nurses in this study felt that being able to access information at the point-of-care increased their confidence and facilitated the provision of quality care because it assisted them in being accurate and sure of what they were doing.

  11. Experiences of registered nurses with regard to accessing health information at the point-of-care via mobile computing devices.

    Science.gov (United States)

    Ricks, Esmeralda; Benjamin, Valencia; Williams, Margaret

    2015-11-19

    The volume of health information necessary to provide competent health care today has become overwhelming. Mobile computing devices are fast becoming an essential clinical tool for accessing health information at the point-of-care of patients. This study explored and described how registered nurses experienced accessing information at the point-of-care via mobile computing devices (MCDs). A qualitative, exploratory, descriptive and contextual design was used. Ten in-depth interviews were conducted with purposively sampled registered nurses employed by a state hospital in the Nelson Mandela Bay Municipality (NMBM). Interviews were recorded, transcribed verbatim and analysed using Tesch's data analysis technique. Ethical principles were adhered to throughout the study. Guba's model of trustworthiness was used to confirm integrity of the study. Four themes emerged which revealed that the registered nurses benefited from the training they received by enabling them to develop, and improve, their computer literacy levels. Emphasis was placed on the benefits that the accessed information had for educational purposes for patients and the public, for colleagues and students. Furthermore the ability to access information at the point-of-care was considered by registered nurses as valuable to improve patient care because of the wide range of accurate and readily accessible information available via the mobile computing device. The registered nurses in this study felt that being able to access information at the point-of-care increased their confidence and facilitated the provision of quality care because it assisted them in being accurate and sure of what they were doing.

  12. A QSPR STUDY OF NORMAL BOILING POINT OF ORGANIC COMPOUNDS (ALIPHATIC ALKANES USING MOLECULAR DESCRIPTORS

    Directory of Open Access Journals (Sweden)

    B. Souyei

    2013-12-01

    Full Text Available A quantitative structure–property relationship (QSPR study is carried out to develop correlations that relate the molecular structures of organic compounds (Aliphatic Alkanes to their normal boiling point (NBP and two correlations were proposed for constitutionals and connectivity indices Models. The correlations are simple in application with good accuracy, which provide an easy, direct and relatively accurate way to calculate NBP. Such calculation gives us a model that gives results in remarkable correlations with the descriptors of blokes constitutionals (CON, and connectivity indices (CI (R2 = 0.950, δ = 0.766 (R2 = 0.969, δ = 0.782 respectively.

  13. The primary care amplification model: taking the best of primary care forward

    Directory of Open Access Journals (Sweden)

    Nicholson Caroline

    2008-12-01

    Full Text Available Abstract Background Primary care internationally is approaching a new paradigm. The change agenda implicit in this threatens to de-stabilise and challenge established general practice and primary care. Discussion The Primary Care Amplification Model offers a means to harness the change agenda by 'amplifying' the strengths of established general practices around a 'beacon' practice. Conclusion Such 'beacon' practices can provide a mustering point for an expanded scope of practice for primary care, integrated primary/secondary service delivery, interprofessional learning, relevant local clinical research, and a focus on local service innovation, enhancing rather than fragmenting the collective capacity of existing primary care.

  14. The Role of Internal Reference Points in the Category Purchase Decision.

    OpenAIRE

    Bell, David R; Bucklin, Randolph E

    1999-01-01

    The authors study the role that reference effects play in the category purchase decision for consumer nondurable products. Category purchase behavior is represented by a nested logit model that is estimated on purchase records of shoppers in two Universal Product Code (UPC) scanner panels. A series of hypotheses are developed, modeled, and tested regarding the effects that internal reference points for product category attractiveness are likely to have on the decision to buy in a product cate...

  15. Knowledge of palliative care among medical interns in a tertiary health institution in Northwestern Nigeria

    Directory of Open Access Journals (Sweden)

    Daniel Chukwunyere Nnadi

    2016-01-01

    Full Text Available Background: Palliative care is the proactive care which seeks to maximize quality of life for people and families facing life-threatening illnesses. Objectives: To ascertain the existing knowledge of palliative care among medical interns and determine the effect of a structured educational intervention on improvement of their knowledge levels. Subjects and Methods: This is a quasi-experimental, interventional study with a one group pre- and post-test design involving medical interns rotating through the various departments of the Usmanu Danfodiyo University Teaching Hospital, Sokoto. The study population was chosen by convenience sampling method. The interns completed a pre- and a post-test assessment following a structured educational intervention for the evaluation of knowledge of palliative care. Knowledge was evaluated by a self-administered structured questionnaire. Results: A total number of 49 medical interns were recruited, among whom were 41 males and 8 females. Their ages ranged from 21 to 36 years with a mean of 27.7 (standard deviation 2.14 years. In the pretest, 11/49 (22.5% of the respondents had poor knowledge level of palliative care; however, in the postintervention, only 2/49 (4.1% of the respondents had poor knowledge. Similarly, good knowledge levels appreciated from 9/49 (18.4% to 14/49 (28.6% while very good knowledge increased from 10/49 (20.4% to 19/49 (38.8%. This effect was statistically significant (Chi-square test 11.655 df = 3, P = 0.009. Conclusion: There is poor knowledge of palliative care among the interns due to ignorance. Following an educational intervention, the knowledge levels appreciated significantly. Palliative care should be part of the medical curriculum.

  16. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Teerenstra, S.; Klein Gunnewiek, J.M.T.; Weerwind, P.W.

    2008-01-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of

  17. Quench pressure, thermal expulsion, and normal zone propagation in internally cooled superconductors

    International Nuclear Information System (INIS)

    Dresner, L.

    1988-01-01

    When a nonrecovering normal zone appears in an internally cooled superconductor, the pressure in the conductor rises, helium is expelled from its ends, and the normal zone grows in size. This paper presents a model of these processes that allows calculation of the pressure, the expulsion velocity, and the propagation velocity with simple formulas. The model is intended to apply to conductors such as the cable-in-conduit conductor of the Westinghouse LCT (WH-LCT) coil, the helium volumes of which have very large length-to-diameter ratios (3 /times/ 10 5 ). The predictions of the model agree with the rather limited data available from propagation experiments carried out on the WH-LCT coil. 3 refs., 1 fig

  18. Disintegrated care: the Achilles heel of international health policies in low and middle-income countries

    Directory of Open Access Journals (Sweden)

    Jean-Pierre Unger

    2006-09-01

    Full Text Available Purpose: To review the evidence basis of international aid and health policy. Context of case: Current international aid policy is largely neoliberal in its promotion of commoditization and privatisation. We review this policy's responsibility for the lack of effectiveness in disease control and poor access to care in low and middle-income countries. Data sources: National policies, international programmes and pilot experiments are examined in both scientific and grey literature. Conclusions and discussion: We document how health care privatisation has led to the pool of patients being cut off from public disease control interventions—causing health care disintegration—which in turn resulted in substandard performance of disease control. Privatisation of health care also resulted in poor access. Our analysis consists of three steps. Pilot local contracting-out experiments are scrutinized; national health care records of Colombia and Chile, two countries having adopted contracting-out as a basis for health care delivery, are critically examined against Costa Rica; and specific failure mechanisms of the policy in low and middle-income countries are explored. We conclude by arguing that the negative impact of neoliberal health policy on disease control and health care in low and middle-income countries justifies an alternative aid policy to improve both disease control and health care.

  19. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system

    Directory of Open Access Journals (Sweden)

    Jing Cao

    2017-12-01

    Full Text Available Background: Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc. Methods: Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Results: Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Conclusion: Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. Impact of the study: This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing. Keywords: Epoc, Capillary, Transport, Blood gas, Point of care

  20. Raman Spectroscopy as a Promising Tool for Noninvasive Point-of-Care Glucose Monitoring

    NARCIS (Netherlands)

    Scholtes-Timmerman, M.J.; Bijlsma, S.; Fokkert, M.J.; Slingerland, R.; Veen, S.J.F. van

    2014-01-01

    Self-monitoring of glucose is important for managing diabetes. Noninvasive glucose monitors are not yet available, but patients would benefit highly from such a device. We present results that may lead to a novel, point-of-care noninvasive system to measure blood glucose based on Raman spectroscopy.

  1. Point-of-care C-reactive protein-based tuberculosis screening for people living with HIV: a diagnostic accuracy study.

    Science.gov (United States)

    Yoon, Christina; Semitala, Fred C; Atuhumuza, Elly; Katende, Jane; Mwebe, Sandra; Asege, Lucy; Armstrong, Derek T; Andama, Alfred O; Dowdy, David W; Davis, J Luke; Huang, Laurence; Kamya, Moses; Cattamanchi, Adithya

    2017-12-01

    Symptom-based screening for tuberculosis is recommended for all people living with HIV. This recommendation results in unnecessary Xpert MTB/RIF testing in many individuals living in tuberculosis-endemic areas and thus poor implementation of intensified case finding and tuberculosis preventive therapy. Novel approaches to tuberculosis screening are needed to help achieve global targets for tuberculosis elimination. We assessed the performance of C-reactive protein (CRP) measured with a point-of-care assay as a screening tool for active pulmonary tuberculosis. For this prospective study, we enrolled adults (aged ≥18 years) living with HIV with CD4 cell count less than or equal to 350 cells per μL who were initiating antiretroviral therapy (ART) from two HIV/AIDS clinics in Uganda. CRP concentrations were measured at study entry with a point-of-care assay using whole blood obtained by fingerprick (concentration ≥10 mg/L defined as screen positive for tuberculosis). Sputum samples were collected for Xpert MTB/RIF testing and culture. We calculated the sensitivity and specificity of point-of-care CRP and WHO symptom-based screening in reference to culture results. We repeated the sensitivity analysis with Xpert MTB/RIF as the reference standard. Between July 8, 2013, and Dec 15, 2015, 1237 HIV-infected adults were enrolled and underwent point-of-care CRP testing. 60 (5%) patients with incomplete or contaminated cultures were excluded from the analysis. Of the remaining 1177 patients (median CD4 count 165 cells per μL [IQR 75-271]), 163 (14%) had culture-confirmed tuberculosis. Point-of-care CRP testing had 89% sensitivity (145 of 163, 95% CI 83-93) and 72% specificity (731 of 1014, 95% CI 69-75) for culture-confirmed tuberculosis. Compared with WHO symptom-based screening, point-of-care CRP testing had lower sensitivity (difference -7%, 95% CI -12 to -2; p=0·002) but substantially higher specificity (difference 58%, 95% CI 55 to 61; ptuberculosis screening test

  2. Keratoconus Progression in Patients With Allergy and Elevated Surface Matrix Metalloproteinase 9 Point-of-Care Test.

    Science.gov (United States)

    Mazzotta, Cosimo; Traversi, Claudio; Mellace, Pierfrancesco; Bagaglia, Simone A; Zuccarini, Silvio; Mencucci, Rita; Jacob, Soosan

    2017-10-04

    To assess keratoconus (KC) progression in patients with allergies who also tested positive to surface matrix metalloproteinase 9 (MMP-9) point-of-care test. Prospective comparative study including 100 stage I-II keratoconic patients, mean age 16.7±4.6 years. All patients underwent an anamnestic questionnaire for concomitant allergic diseases and were screened with the MMP-9 point-of-care test. Patients were divided into two groups: patients KC with allergies (KC AL) and patients KC without allergies (KC NAL). Severity of allergy was established by papillary subtarsal response grade and KC progression assessed by Scheimpflug corneal tomography, corrected distance visual acuity (CDVA) measurement in a 12-month follow-up. The KC AL group included 52 patients and the KC NAL group 48. In the KC AL group, 42/52 of patients (81%) were positive to MMP-9 point-of-care test versus two positive patients in the KC NAL group (4%). The KC AL group data showed a statistically significant decrease of average CDVA, from 0.155±0.11 to 0.301±0.2 logarithm of the minimum angle of resolution (Paverage. The KC NAL group revealed a slight KC progression without statistically significant changes. Pearson correlation test showed a high correlation between Kmax worsening and severity of PSR in the KC AL group. The study demonstrated a statistically significant progression of KC in patients with concomitant allergies, positive to MMP-9 point-of-care test versus negative. A high correlation between severity of allergy and KC progression was documented.

  3. The factorial reliability of the Middlesex Hospital Questionnaire in normal subjects.

    Science.gov (United States)

    Bagley, C

    1980-03-01

    The internal reliability of the Middlesex Hospital Questionnaire and its component subscales has been checked by means of principal components analyses of data on 256 normal subjects. The subscales (with the possible exception of Hysteria) were found to contribute to the general underlying factor of psychoneurosis. In general, the principal components analysis points to the reliability of the subscales, despite some item overlap.

  4. Design of point-of-care (POC) microfluidic medical diagnostic devices

    Science.gov (United States)

    Leary, James F.

    2018-02-01

    Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.

  5. Point-of-care rare cell cancer diagnostics.

    Science.gov (United States)

    Issadore, David

    2015-01-01

    The sparse cells that are shed from tumors into peripheral circulation are an increasingly promising resource for noninvasive monitoring of cancer progression, early diagnosis of disease, and serve as a tool for improving our understanding of cancer metastasis. However, the extremely sparse concentration of circulating tumor cells (CTCs) in blood (~1-100 CTC in 7.5 mL of blood) as well as their heterogeneous biomarker expression has limited their detection using conventional laboratory techniques. To overcome these challenges, we have developed a microfluidic chip-based micro-Hall detector (μHD), which can directly measure single, immunomagnetically tagged cells in whole blood. The μHD can detect individual cells even in the presence of vast numbers of blood cells and unbound reactants, and does not require any washing or purification steps. Furthermore, this cost-effective, single-cell analytical technique is well suited for miniaturization into a mobile platform for low-cost point-of-care use. In this chapter, we describe the methodology used to design, fabricate, and apply these chips to cancer diagnostics.

  6. Adaptation and validation of the patient assessment of chronic illness care in the French context.

    Science.gov (United States)

    Krucien, Nicolas; Le Vaillant, Marc; Pelletier-Fleury, Nathalie

    2014-06-19

    Chronic diseases are major causes of disability worldwide with rising prevalence. Most patients suffering from chronic conditions do not always receive optimal care. The Chronic Care Model (CCM) has been developed to help general practitioners making quality improvements. The Patient Assessment of Chronic Illness Care (PACIC) questionnaire was increasingly used in several countries to appraise the implementation of the CCM from the patients' perspective. The objective of this study was to adapt the PACIC questionnaire in the French context and to test the validity of this adaptation in a sample of patients with multiple chronic conditions. The PACIC was translated into French language using a forward/backward procedure. The French version was validated using a sample of 150 patients treated for obstructive sleep apnea syndrome (OSAS) and having multiple chronic co-morbidities. Several forms of validity were analysed: content; face; construct; and internal consistency. The construct validity was investigated with an exploratory factorial analysis. The French-version of the PACIC consisted in 18 items, after merging two pairs of items due to redundancy. The high number of items exhibiting floor/ceiling effects and the non-normality of the ratings suggested that a 5-points rating scale was somewhat inappropriate to assess the patients' experience of care. The construct validity of the French-PACIC was verified and resulted in a bi-dimensional structure. Overall this structure showed a high level of internal consistency. The PACIC score appeared to be significantly related to the age and self-reported health of the patients. A French-version of the PACIC questionnaire is now available to evaluate the patients' experience of care and to monitor the quality improvements realised by the medical structures. This study also pointed out some methodological issues about the PACIC questionnaire, related to the format of the rating scale and to the structure of the

  7. Plasma-equivalent glucose at the point-of-care: evaluation of Roche Accu-Chek Inform and Abbott Precision PCx glucose meters.

    Science.gov (United States)

    Ghys, Timothy; Goedhuys, Wim; Spincemaille, Katrien; Gorus, Frans; Gerlo, Erik

    2007-01-01

    Glucose testing at the bedside has become an integral part of the management strategy in diabetes and of the careful maintenance of normoglycemia in all patients in intensive care units. We evaluated two point-of-care glucometers for the determination of plasma-equivalent blood glucose. The Precision PCx and the Accu-Chek Inform glucometers were evaluated. Imprecision and bias relative to the Vitros 950 system were determined using protocols of the Clinical Laboratory Standards Institute (CLSI). The effects of low, normal, and high hematocrit levels were investigated. Interference by maltose was also studied. Within-run precision for both instruments ranged from 2-5%. Total imprecision was less than 5% except for the Accu-Chek Inform at the low level (2.9 mmol/L). Both instruments correlated well with the comparison instrument and showed excellent recovery and linearity. Both systems reported at least 95% of their values within zone A of the Clarke Error Grid, and both fulfilled the CLSI quality criteria. The more stringent goals of the American Diabetes Association, however, were not reached. Both systems showed negative bias at high hematocrit levels. Maltose interfered with the glucose measurements on the Accu-Chek Inform but not on the Precision PCx. Both systems showed satisfactory imprecision and were reliable in reporting plasma-equivalent glucose concentrations. The most stringent performance goals were however not met.

  8. Assisted Living Facilities - CARE_LONG_TERM_FACILITIES_ISDH_IN: Residential Care Facilities, Nursing Homes, and Hospices in Indiana in 2007 (Indiana State Department of Health, Point Shapefile)

    Data.gov (United States)

    NSGIC State | GIS Inventory — CARE_LONG_TERM_FACILITIES_ISDH_IN is a point shapefile showing the locations of 86 residential care facilities, 525 long-term care facilities (nursing homes), and 81...

  9. Hematocrit Causes the Most Significant Error in Point of Care Glucometers

    Science.gov (United States)

    2009-04-01

    Videofluoroscopic evaluation of as- piration with visual examination of the gag reflex and velar movement. Dysphagia 1997; 12:21–23 5. Navalesi P, Frigerio P...care glucometers To the Editor: The study by Hoedemaekers et al (1) has failed to identify the most likely and proven confounder for accuracy of point...cohort of critically ill patients. Because no validation studies using this correc- tion factor have been published so far, it should be used with great

  10. Palliative care in amyotrophic lateral sclerosis: a review of current international guidelines and initiatives.

    Science.gov (United States)

    Bede, Peter; Oliver, David; Stodart, James; van den Berg, Leonard; Simmons, Zachary; O Brannagáin, Doiminic; Borasio, Gian Domenico; Hardiman, Orla

    2011-04-01

    Amyotrophic lateral sclerosis (ALS) is a relentlessly progressive neurodegenerative condition. Optimal management requires a palliative approach from diagnosis with emphasis on patient autonomy, dignity and quality of life. To conduct a systematic analysis of the type, level and timing of specialist palliative care intervention in ALS. Despite an international consensus that ALS management should adopt a multidisciplinary approach, integration of palliative care into ALS management varies considerably across health care systems. Late referral to palliative services in ALS is not uncommon and may impact negatively on the quality of life of ALS patients and their caregivers. However, common themes and principles of engagement can be identified across different jurisdictions, and measurement systems have been established that can assess the impact of palliative care intervention. There is considerable evidence that palliative care intervention improves quality of life in patients and carers. International consensus guidelines would assist in the development of a framework for active palliative care engagement in ALS and other neurodegenerative diseases.

  11. Therapeutic Residential Care for Children and Youth : A Consensus Statement of the International Work Group on Therapeutic Residential Care

    NARCIS (Netherlands)

    Whittaker, James K.; Holmes, Lisa; del Valle, Jorge F.; Ainsworth, Frank; Andreassen, Tore; Anglin, James P.; Bellonci, Christopher; Berridge, David; Bravo, Amaia; Canali, Cinzia; Courtney, Mark; Currey, Laura; Daly, Daniel L.; Gilligan, Robbie; Grietens, Hans; Harder, Annemiek T.; Holden, Martha J.; James, Sigrid; Kendrick, Andrew; Knorth, Erik J.; Lausten, Mette; Lyons, John S.; Martin, Eduardo; McDermid, Samantha; McNamara, Patricia; Palareti, Laura; Ramsey, Susan; Sisson, Kari M.; Small, Richard W.; Thoburn, June; Thompson, Ronald; Zeira, Anat

    While the focus of this consensus statement and the review volume that preceded it (Whittaker, Del Valle, & Holmes, 2014) is on therapeutic residential care (TRC), a specialized form of group care, we view our work as supportive of a much wider effort internationally concerned with the quality of

  12. Simple, rapid, and affordable point-of-care test for the serodiagnosis of typhoid fever

    NARCIS (Netherlands)

    Pastoor, Rob; Hatta, Mochammad; Abdoel, Theresia H.; Smits, Henk L.

    2008-01-01

    We developed a point-of-care test for the serodiagnosis of typhoid fever in the format of an immunochromatographic lateral flow assay. The flow assay for typhoid fever is based on the detection of Salmonella enterica serotype Typhi lipopolysaccharide-specific immunoglobulin M (IgM) antibodies. The

  13. Hypertriglyceridemic waist phenotype in primary health care: comparison of two cutoff points

    Directory of Open Access Journals (Sweden)

    Braz MAD

    2017-09-01

    Full Text Available Marina Augusta Dias Braz,1 Jallyne Nunes Vieira,1 Flayane Oliveira Gomes,1 Priscilla Rafaella da Silva,1 Ohanna Thays de Medeiros Santos,1 Ilanna Marques Gomes da Rocha,2 Iasmin Matias de Sousa,2 Ana Paula Trussardi Fayh2 1Faculdade de Ciências da Saúde do Trairi, Universidade Federal do Rio Grande do Norte (UFRN, Santa Cruz, 2Department of Nutrition, Centro de Ciências da Saúde, UFRN, Natal, Rio Grande do Norte, Brazil Objective: We aimed to evaluate the prevalence of hypertriglyceridemic waist (HTGW phenotype among users of primary health care using two different cutoff points used in the literature. Methods: We evaluated adults and elderly individuals of both sexes who attended the same level of primary health care. HTGW phenotype was determined with measurements of waist circumference (WC and triglyceride levels and compared using cutoff points proposed by the National Cholesterol Education Program – NCEP/ATP III (WC ≥102 cm for men and ≥88 cm for women; triglyceride levels ≥150 mg/dL for both sexes and by Lemieux et al (WC ≥90 cm for men and ≥85 cm for women; triglyceride levels ≥177 mg/dL for both. Results: Within the sample of 437 individuals, 73.7% was female. The prevalence of HTGW phenotype was high and statistically different with the use of different cutoff points from the literature. The prevalence was higher using the NCEP/ATP III criteria compared to those proposed by Lemieux et al (36.2% and 32.5%, respectively, p<0.05. Individuals with the presence of the phenotype also presented alterations in other traditional cardiovascular risk markers. Conclusion: The HTGW phenotype identified high prevalence of cardiovascular risk in the population, with higher cutoff points from the NCEP/ATP III criteria. The difference in frequency of risk alerts us to the need to establish cutoff points for the Brazilian population. Keywords: abdominal obesity, cardiovascular disease, dyslipidemia, cardiovascular risk

  14. Nanoparticle Detection of Urinary Markers for Point-of-Care Diagnosis of Kidney Injury.

    Directory of Open Access Journals (Sweden)

    Hyun Jung Chung

    Full Text Available The high incidence of acute and chronic kidney injury due to various environmental factors such as heavy metals or chemicals has been a major problem in developing countries. However, the diagnosis of kidney injury in these areas can be more challenging due to the lack of highly sensitive and specific techniques that can be applied in point-of-care settings. To address this, we have developed a technique called 'micro-urine nanoparticle detection (μUNPD', that allows the detection of trace amounts of molecular markers in urine. Specifically, this technique utilizes an automated on-chip assay followed by detection with a hand-held device for the read-out. Using the μUNPD technology, the kidney injury markers KIM-1 and Cystatin C were detected down to concentrations of 0.1 ng/ml and 20 ng/ml respectively, which meets the cut-off range required to identify patients with acute or chronic kidney injury. Thus, we show that the μUNPD technology enables point of care and non-invasive detection of kidney injury, and has potential for applications in diagnosing kidney injury with high sensitivity in resource-limited settings.

  15. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  16. Point-of-Care Healthcare Databases Are an Overall Asset to Clinicians, but Different Databases May Vary in Usefulness Based on Personal Preferences. A Review of: Chan, R. & Stieda, V. (2011). Evaluation of three point-of-care healthcare databases: BMJ Point-of-Care, Clin-eguide and Nursing Reference Centre. Health and Information Libraries Journal, 28(1), 50-58. doi: 10.1111/j.1471-1842.2010.00920.x

    OpenAIRE

    Carol D. Howe

    2011-01-01

    Objective – To evaluate the usefulness of three point-of-care healthcare databases (BMJ Point-of-Care, Clin-eguide, and Nursing Reference Centre) in clinical practice.Design – A descriptive study analyzing questionnaire results.Setting – Hospitals within Alberta, Canada’s two largest health regions (at the time of this study), with a third health region submitting a small number of responses.Subjects – A total of 46 Alberta hospital personnel answered the questionnaire, including 19 clinician...

  17. Efforts made for health and medical care by International Atomic Energy Agency

    International Nuclear Information System (INIS)

    Watanabe, Naoyuki

    2016-01-01

    The author, being a former senior medical officer and currently a consultant of the Nuclear Medicine Section, the Division of Human Health, the Department of Nuclear Sciences and Applications, the International Atomic Energy Agency (IAEA) to standardize the isotope and radiation technologies for health and medical care and transfer them to the IAEA member states to address their health issues, participated in an international cooperation project to survey the current situation of the health and medical care in Viet Nam and exchange opinions with the World Health Organization Western Pacific Regional Office Viet Nam Office and the Viet Nam Health Department coordinated by the Japan Public Health Association from 10th to 15th January 2016 and perceived efforts made and action plans for the health and medical care in Viet Nam by the international organizations of the IAEA and the World Health Organization (WHO). IAEA has verified various isotopes and radiation technologies up to now in the international field of health and medical care and has being offered them to the member states under the sustainable frame work of technical co-operation. However, the activity in the health and medical care field of IAEA is hardly recognized by the public health professionals in Japan. In order to attain the objective to improve and maintain human health under the umbrella of the United Nations system, the peaceful use of nuclear technology has been promoted in the field of non-electric applications of nuclear energy including human health and medical care by the IAEA. There are several discrepancies seen with the field and tactics of health and medical care between the IAEA and the WHO. In terms of measures to fight NCDs which should be an urgent issue in most of the member states, a comprehensive approach is often needed beyond the capability of IAEA as isotopes and radiation technologies. The IAEA should strive to solve issues on human health and medical care maintaining much

  18. Comparability of Results Between a Point-of-Care and an Automated Instrument for Measurement of B-Type Natriuretic Peptide

    OpenAIRE

    Shah, Kevin; Terracciano, Garrett J; Jiang, Kevin; Maisel, Alan S; Fitzgerald, Robert L

    2010-01-01

    Objectives: Heart failure is one of the leading causes of death in the U.S. The incorporation of B-type natriuretic peptide (BNP) measurements when triaging patients presenting with shortness of breath has improved the diagnostic and prognostic ability of physicians. Currently, there are no point-of-care systems for quantifying BNP that can be used without sacrificing accuracy. We compared the analytical performance of the Abbott i-STAT analyzer, a handheld point-of-care system for measuring ...

  19. Sexual abuse of children in residential care : an international review

    NARCIS (Netherlands)

    Timmerman, Margaretha; Schreuder, Pauline

    2014-01-01

    This paper reports the results of an international review of academic literature on sexual abuse in residential child and youth care, 1945-2011. The review focusses on questions related to the nature and scope of sexual abuse, on personal and institutional factors providing either protection or

  20. 2nd International Conference on Health Care Systems Engineering

    CERN Document Server

    Sahin, Evren; Li, Jingshan; Guinet, Alain; Vandaele, Nico

    2016-01-01

    In this volume, scientists and practitioners write about new methods and technologies for improving the operation of health care organizations. Statistical analyses play an important role in these methods with the implications of simulation and modeling applied to the future of health care. Papers are based on work presented at the Second International Conference on Health Care Systems Engineering (HCSE2015) in Lyon, France. The conference was a rare opportunity for scientists and practitioners to share work directly with each other. Each resulting paper received a double blind review. Paper topics include: hospital drug logistics, emergency care, simulation in patient care, and models for home care services. Discusses statistical analysis and operations management for health care delivery systems based on real case studies Papers in this volume received a double blind review Brings together the work of scientists, practitioners, and clinicians to unite research and practice in the future of these systems Top...

  1. International benchmarking and best practice management: in search of health care and hospital excellence.

    Science.gov (United States)

    von Eiff, Wilfried

    2015-01-01

    Hospitals worldwide are facing the same opportunities and threats: the demographics of an aging population; steady increases in chronic diseases and severe illnesses; and a steadily increasing demand for medical services with more intensive treatment for multi-morbid patients. Additionally, patients are becoming more demanding. They expect high quality medicine within a dignity-driven and painless healing environment. The severe financial pressures that these developments entail oblige care providers to more and more cost-containment and to apply process reengineering, as well as continuous performance improvement measures, so as to achieve future financial sustainability. At the same time, regulators are calling for improved patient outcomes. Benchmarking and best practice management are successfully proven performance improvement tools for enabling hospitals to achieve a higher level of clinical output quality, enhanced patient satisfaction, and care delivery capability, while simultaneously containing and reducing costs. This chapter aims to clarify what benchmarking is and what it is not. Furthermore, it is stated that benchmarking is a powerful managerial tool for improving decision-making processes that can contribute to the above-mentioned improvement measures in health care delivery. The benchmarking approach described in this chapter is oriented toward the philosophy of an input-output model and is explained based on practical international examples from different industries in various countries. Benchmarking is not a project with a defined start and end point, but a continuous initiative of comparing key performance indicators, process structures, and best practices from best-in-class companies inside and outside industry. Benchmarking is an ongoing process of measuring and searching for best-in-class performance: Measure yourself with yourself over time against key performance indicators. Measure yourself against others. Identify best practices. Equal or

  2. The social role of C-reactive protein point-of-care testing to guide antibiotic prescription in Northern Thailand.

    Science.gov (United States)

    Haenssgen, Marco J; Charoenboon, Nutcha; Althaus, Thomas; Greer, Rachel C; Intralawan, Daranee; Lubell, Yoel

    2018-04-01

    New and affordable point-of-care testing (POCT) solutions are hoped to guide antibiotic prescription and to help limit antimicrobial resistance (AMR)-especially in low- and middle-income countries where resource constraints often prevent extensive diagnostic testing. Anthropological and sociological research has illuminated the role and impact of rapid point-of-care malaria testing. This paper expands our knowledge about the social implications of non-malarial POCT, using the case study of a C-reactive-protein point-of-care testing (CRP POCT) clinical trial with febrile patients at primary-care-level health centres in Chiang Rai province, northern Thailand. We investigate the social role of CRP POCT through its interactions with (a) the healthcare workers who use it, (b) the patients whose routine care is affected by the test, and (c) the existing patient-health system linkages that might resonate or interfere with CRP POCT. We conduct a thematic analysis of data from 58 purposively sampled pre- and post-intervention patients and healthcare workers in August 2016 and May 2017. We find widespread positive attitudes towards the test among patients and healthcare workers. Patients' views are influenced by an understanding of CRP POCT as a comprehensive blood test that provides specific diagnosis and that corresponds to notions of good care. Healthcare workers use the test to support their negotiations with patients but also to legitimise ethical decisions in an increasingly restrictive antibiotic policy environment. We hypothesise that CRP POCT could entail greater patient adherence to recommended antibiotic treatment, but it could also encourage riskier health behaviour and entail potentially adverse equity implications for patients across generations and socioeconomic strata. Our empirical findings inform the clinical literature on increasingly propagated point-of-care biomarker tests to guide antibiotic prescriptions, and we contribute to the anthropological and

  3. Modular microfluidics for point-of-care protein purifications.

    Science.gov (United States)

    Millet, L J; Lucheon, J D; Standaert, R F; Retterer, S T; Doktycz, M J

    2015-04-21

    Biochemical separations are the heart of diagnostic assays and purification methods for biologics. On-chip miniaturization and modularization of separation procedures will enable the development of customized, portable devices for personalized health-care diagnostics and point-of-use production of treatments. In this report, we describe the design and fabrication of miniature ion exchange, size exclusion and affinity chromatography modules for on-chip clean-up of recombinantly-produced proteins. Our results demonstrate that these common separations techniques can be implemented in microfluidic modules with performance comparable to conventional approaches. We introduce embedded 3-D microfluidic interconnects for integrating micro-scale separation modules that can be arranged and reconfigured to suit a variety of fluidic operations or biochemical processes. We demonstrate the utility of the modular approach with a platform for the enrichment of enhanced green fluorescent protein (eGFP) from Escherichia coli lysate through integrated affinity and size-exclusion chromatography modules.

  4. Point of care creatinine measurement for diagnosis of renal disease using a disposable microchip

    NARCIS (Netherlands)

    Ávila Muñoz, Mónica; Floris, J.; Staal, S.S.; Ríos, Ángel; Eijkel, Jan C.T.; van den Berg, Albert

    2013-01-01

    A point-of-care device for the determination of elevated creatinine levels in blood is reported. This device potentially offers a new and simple clinical regime for the determination of creatinine that will give huge time savings and removal of several steps of determination. The test employs a

  5. The role of point-of-care blood testing for ketones in the diagnosis of ...

    African Journals Online (AJOL)

    estimated that the annual cost of treating DKA in the USA exceeds. 1 billion ... If urinary ketones are positive, patients are referred for further management – often ... To evaluate a hand-held electrochemical (point-of-care testing; POCT) ketone monitor and compare it with the gold-standard ..... renal failure may be present.

  6. Nine-point plan to improve care of the injured patient: A case study from Kenya.

    Science.gov (United States)

    Bachani, Abdulgafoor M; Botchey, Isaac; Paruk, Fatima; Wako, Daniel; Saidi, Hassan; Aliwa, Bethuel; Kibias, Simon; Hyder, Adnan A

    2017-12-01

    Injury rates in low- and middle-income countries are among the greatest in the world, with >90% of unintentional injury occurring in low- or middle-income countries. The risk of death from injuries is 6 times more in low- and middle-income countries than in high-income countries. This increased rate of injury is partly due to the lack of availability and access to timely and appropriate medical care for injured individuals. Kenya, like most low- and middle-income countries, has seen a 5-fold increase in injury fatalities throughout the past 4 decades, in large part related to the absence of a coordinated, integrated system of trauma care. We aimed to assess the trauma-care system in Kenya and to develop and implement a plan to improve it. A trauma system profile was performed to understand the landscape for the care of the injured patient in Kenya. This process helped identify key gaps in care ranging from prehospital to hospital-based care. In response to this observation, a 9-point plan to improve trauma care in Kenya was developed and implemented in close collaboration with local stakeholders. The 9-point plan was centered on engagement of the stakeholders, generation of key data to guide and improve services, capacity development for prehospital and hospital care, and strengthening policy and legislation. There is an urgent need for coordinated strategies to provide appropriate and timely medical care to injured individuals in low- or middle-income countries to decrease the burden of injuries and related fatalities. Our work in Kenya shows that such an integrated system of trauma care could be achieved through a step-by-step integrated and multifaceted approach that emphasizes engagement of local stakeholders and evidence-based approaches to ensure effectiveness, efficiency, and sustainability of system-wide improvements. This plan and lessons learned in its development and implementation could be adaptable to other similar settings to improve the care of the

  7. Point-of-Care Testing for Anemia, Diabetes, and Hypertension: A Pharmacy-Based Model in Lima, Peru.

    Science.gov (United States)

    Saldarriaga, Enrique M; Vodicka, Elisabeth; La Rosa, Sayda; Valderrama, Maria; Garcia, Patricia J

    Prevention and control of chronic diseases is a high priority for many low- and middle-income countries. This study evaluated the feasibility and acceptability of training pharmacy workers to provide point-of-care testing for 3 chronic diseases-hypertension, diabetes, and anemia-to improve disease detection and awareness through private pharmacies. We developed a multiphase training curriculum for pharmacists and pharmacy technicians to build capacity for identification of risk factors, patient education, point-of-care testing, and referral for abnormal results. We conducted a pre-post evaluation with participants and evaluated results using Student t test for proportions. We conducted point-of-care testing with pharmacy clients and evaluated acceptability by patient characteristics (age, gender, and type of patient) using multiple logistic regression. In total, 72 pharmacy workers (66%) completed the full training curriculum. Pretest scores indicated that pharmacists had more knowledge and skills in chronic disease risk factors, patient education, and testing than pharmacy technicians. All participants improved their knowledge and skills after the training, and post-test scores indicated that pharmacy technicians achieved the same level of competency as pharmacists (P anemia than a traditional health center. Fast service was very important: 41% ranked faster results and 30% ranked faster attention as the most important factor for receiving diagnostic testing in the pharmacy. We found that it is both feasible for pharmacies and acceptable to clients to train pharmacy workers to provide point-of-care testing for anemia, diabetes, and hypertension. This innovative approach holds potential to increase early detection of risk factors and bolster disease prevention and management efforts in Peru and other low- and middle-income settings. Copyright © 2017. Published by Elsevier Inc.

  8. [Factor analysis and internal consistency of pedagogical practices questionnaire among health care teachers].

    Science.gov (United States)

    Pérez V, Cristhian; Vaccarezza G, Giulietta; Aguilar A, César; Coloma N, Katherine; Salgado F, Horacio; Baquedano R, Marjorie; Chavarría R, Carla; Bastías V, Nancy

    2016-06-01

    Teaching practice is one of the most complex topics of the training process in medicine and other health care careers. The Teaching Practices Questionnaire (TPQ) evaluates teaching skills. To assess the factor structure and internal consistency of the Spanish version of the TPP among health care teachers. The TPQ was answered by 315 university teachers from 13 of the 15 administrative Chilean regions, who were selected through a non-probabilistic volunteer sampling. The internal consistency of TPP factors was calculated and the correlation between them was analyzed. Six factors were identified: Student-centered teaching, Teaching planning, Assessment process, Dialogue relationship, Teacher-centered teaching and Use of technological resources. They had Cronbach alphas ranging from 0.60 to 0.85. The factorial structure of TPQ differentiates the most important functions of teaching. It also shows a theoretical consistency and a practical relevance to perform a diagnosis and continuous evaluation of teaching practices. Additionally, it has an adequate internal consistency. Thus, TPQ is valid and reliable to evaluate pedagogical practices in health care careers.

  9. Point-of-care technology: integration for improved delivery of care.

    Science.gov (United States)

    Gregory, Debbie; Buckner, Martha

    2014-01-01

    The growing complexity of technology, equipment, and devices involved in patient care delivery can be staggering and overwhelming. Technology is intended to be a tool to help clinicians, but it can also be a frustrating hindrance if not thoughtfully planned and strategically aligned. Critical care nurses are key partners in the collaborations needed to improve safety and quality through health information technology (IT). Nurses must advocate for systems that are interoperable and adapted to the context of care experiences. The involvement and collaboration between clinicians, information technology specialists, biomedical engineers, and vendors has never been more relevant and applicable. Working together strategically with a shared vision can effectively provide a seamless clinical workflow, maximize technology investments, and ultimately improve patient care delivery and outcomes. Developing a strategic integrated clinical and IT roadmap is a critical component of today's health care environment. How can technology strategy be aligned from the executive suite to the bedside caregiver? What is the model for using clinical workflows to drive technology adoption? How can the voice of the critical care nurse strengthen this process? How can success be assured from the initial assessment and selection of technology to a sustainable support model? What is the vendor's role as a strategic partner and "co-caregiver"?

  10. Validation of the quantitative point-of-care CareStart biosensor for assessment of G6PD activity in venous blood.

    Science.gov (United States)

    Bancone, Germana; Gornsawun, Gornpan; Chu, Cindy S; Porn, Pen; Pal, Sampa; Bansil, Pooja; Domingo, Gonzalo J; Nosten, Francois

    2018-01-01

    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy in the human population affecting an estimated 8% of the world population, especially those living in areas of past and present malaria endemicity. Decreased G6PD enzymatic activity is associated with drug-induced hemolysis and increased risk of severe neonatal hyperbilirubinemia leading to brain damage. The G6PD gene is on the X chromosome therefore mutations cause enzymatic deficiency in hemizygote males and homozygote females while the majority of heterozygous females have an intermediate activity (between 30-80% of normal) with a large distribution into the range of deficiency and normality. Current G6PD qualitative tests are unable to diagnose G6PD intermediate activities which could hinder wide use of 8-aminoquinolines for Plasmodium vivax elimination. The aim of the study was to assess the diagnostic performances of the new Carestart G6PD quantitative biosensor. A total of 150 samples of venous blood with G6PD deficient, intermediate and normal phenotypes were collected among healthy volunteers living along the north-western Thailand-Myanmar border. Samples were analyzed by complete blood count, by gold standard spectrophotometric assay using Trinity kits and by the latest model of Carestart G6PD biosensor which analyzes both G6PD and hemoglobin. Bland-Altman comparison of the CareStart normalized G6PD values to that of the gold standard assay showed a strong bias in values resulting in poor area under-the-curve values for both 30% and 80% thresholds. Performing a receiver operator curve identified threshold values for the CareStart product equivalent to the 30% and 80% gold standard values with good sensitivity and specificity values, 100% and 92% (for 30% G6PD activity) and 92% and 94% (for 80% activity) respectively. The Carestart G6PD biosensor represents a significant improvement for quantitative diagnosis of G6PD deficiency over previous versions. Further improvements

  11. Emerging point of care tests for influenza: innovation or status quo.

    Science.gov (United States)

    Tayo, Adeoluwa; Ellis, Joanna; Linden Phillips, Luan; Simpson, Sue; Ward, Derek J

    2012-07-01

    Point of care tests (POCTs) for influenza potentially offer earlier diagnosis, enabling specific treatment, infection control measures and greater patient convenience and satisfaction. Current POCTs have limited sensitivity, some cannot distinguish influenza types, none differentiate subtypes and are relatively expensive.  To identify and characterise influenza POCTs expected to be available for clinical use in the U.K. by mid-2013, highlighting those with potential benefits over existing tests. Potential developers of influenza POCTs were identified through known manufacturers' websites, Medical Technology trade associations, the EuroScan International Network, an expert advisory group and by searching relevant online sources. Identified companies were asked to provide standard information on relevant technologies. Fifty-six companies were identified, and 29 (52%) responded, identifying 57 potentially relevant technologies. Of these, 40 (70%) were already available or had undetermined status and 5 (9%) were excluded as time to results took over 60 minutes. Of the remaining 12 emerging POCTs, 10 (83%) reportedly enabled differentiation of influenza types and eight differentiation of A subtypes. Nasopharyngeal swabs were the most commonly acceptable sample type; the sample volume ranging from 80 μl to 1.4 ml. Most identified emerging influenza POCTs offered differentiation of influenza type and subtype. Tests claiming this capability include several incorporating reverse transcription polymerase chain reaction assays; though, these also had the longest time to result. However, whilst some identified POCTs exhibit high sensitivity and specificity, most lack published clinical data for assessment, and the overall costs of these technologies remains largely unknown. © 2011 Blackwell Publishing Ltd.

  12. Fully 3D printed integrated reactor array for point-of-care molecular diagnostics.

    Science.gov (United States)

    Kadimisetty, Karteek; Song, Jinzhao; Doto, Aoife M; Hwang, Young; Peng, Jing; Mauk, Michael G; Bushman, Frederic D; Gross, Robert; Jarvis, Joseph N; Liu, Changchun

    2018-06-30

    Molecular diagnostics that involve nucleic acid amplification tests (NAATs) are crucial for prevention and treatment of infectious diseases. In this study, we developed a simple, inexpensive, disposable, fully 3D printed microfluidic reactor array that is capable of carrying out extraction, concentration and isothermal amplification of nucleic acids in variety of body fluids. The method allows rapid molecular diagnostic tests for infectious diseases at point of care. A simple leak-proof polymerization strategy was developed to integrate flow-through nucleic acid isolation membranes into microfluidic devices, yielding a multifunctional diagnostic platform. Static coating technology was adopted to improve the biocompatibility of our 3D printed device. We demonstrated the suitability of our device for both end-point colorimetric qualitative detection and real-time fluorescence quantitative detection. We applied our diagnostic device to detection of Plasmodium falciparum in plasma samples and Neisseria meningitides in cerebrospinal fluid (CSF) samples by loop-mediated, isothermal amplification (LAMP) within 50 min. The detection limits were 100 fg for P. falciparum and 50 colony-forming unit (CFU) for N. meningitidis per reaction, which are comparable to that of benchtop instruments. This rapid and inexpensive 3D printed device has great potential for point-of-care molecular diagnosis of infectious disease in resource-limited settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Multiplexed lateral flow biosensors: Technological advances for radically improving point-of-care diagnoses.

    Science.gov (United States)

    Li, Jia; Macdonald, Joanne

    2016-09-15

    Lateral flow biosensors are a leading technology in point-of-care diagnostics due to their simplicity, rapidness and low cost. Their primacy in this arena continues through technological breakthroughs such as multiplexing: the detection of more than one biomarker in a single assay. Multiplexing capacity is critical for improving diagnostic efficiency, enhancing the diagnostic precision for specific diseases and reducing diagnostic cost. Here we review, for the first time, the various types and strategies employed for creating multiplexed lateral flow biosensors. These are classified into four main categories in terms of specific application or multiplexing level, namely linear, parameter, spatial and conceptual. We describe the practical applications and implications for each approach and compare their advantages and disadvantages. Importantly, multiplexing is still subject to limitations of the traditional lateral flow biosensor, such as sensitivity and specificity. However, by pushing the limitations of the traditional medium into the multiplex arena, several technological breakthroughs are emerging with novel solutions that further expand the utility of lateral flow biosensing for point-of-care applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Profiling health-care accreditation organizations: an international survey.

    Science.gov (United States)

    Shaw, Charles D; Braithwaite, Jeffrey; Moldovan, Max; Nicklin, Wendy; Grgic, Ileana; Fortune, Triona; Whittaker, Stuart

    2013-07-01

    To describe global patterns among health-care accreditation organizations (AOs) and to identify determinants of sustainability and opportunities for improvement. Web-based questionnaire survey. Organizations offering accreditation services nationally or internationally to health-care provider institutions or networks at primary, secondary or tertiary level in 2010. s) External relationships, scope and activity public information. Forty-four AOs submitted data, compared with 33 in a survey 10 years earlier. Of the 30 AOs that reported survey activity in 2000 and 2010, 16 are still active and stable or growing. New and old programmes are increasingly linked to public funding and regulation. While the number of health-care AOs continues to grow, many fail to thrive. Successful organizations tend to complement mechanisms of regulation, health-care funding or governmental commitment to quality and health-care improvement that offer a supportive environment. Principal challenges include unstable business (e.g. limited market, low uptake) and unstable politics. Many organizations make only limited information available to patients and the public about standards, procedures or results.

  15. Awareness, Interest, and Preferences of Primary Care Providers in Using Point-of-Care Cancer Screening Technology.

    Science.gov (United States)

    Kim, Chloe S; Vanture, Sarah; Cho, Margaret; Klapperich, Catherine M; Wang, Catharine; Huang, Franklin W

    2016-01-01

    Well-developed point-of-care (POC) cancer screening tools have the potential to provide better cancer care to patients in both developed and developing countries. However, new medical technology will not be adopted by medical providers unless it addresses a population's existing needs and end-users' preferences. The goals of our study were to assess primary care providers' level of awareness, interest, and preferences in using POC cancer screening technology in their practice and to provide guidelines to biomedical engineers for future POC technology development. A total of 350 primary care providers completed a one-time self-administered online survey, which took approximately 10 minutes to complete. A $50 Amazon gift card was given as an honorarium for the first 100 respondents to encourage participation. The description of POC cancer screening technology was provided in the beginning of the survey to ensure all participants had a basic understanding of what constitutes POC technology. More than half of the participants (57%) stated that they heard of the term "POC technology" for the first time when they took the survey. However, almost all of the participants (97%) stated they were either "very interested" (68%) or "somewhat interested" (29%) in using POC cancer screening technology in their practice. Demographic characteristics such as the length of being in the practice of medicine, the percentage of patients on Medicaid, and the average number of patients per day were not shown to be associated with the level of interest in using POC. These data show that there is a great interest in POC cancer screening technology utilization among this population of primary care providers and vast room for future investigations to further understand the interest and preferences in using POC cancer technology in practice. Ensuring that the benefits of new technology outweigh the costs will maximize the likelihood it will be used by medical providers and patients.

  16. [External and internal financing in health care].

    Science.gov (United States)

    Henke, Klaus-Dirk

    2007-05-15

    The objective of this contribution is to characterize the functional and institutional features of the German health-care system. This takes place after a short introduction and examination of the ongoing debate on health care in Germany. External funding describes the form of revenue generation. Regarding external funding of the German health care system, one of the favored alternatives in the current debate is the possibility of introducing per capita payments. After a short introduction to the capitation option, focus is on the so-called health fund that is currently debated on and being made ready for implementation in Germany, actually a mixed system of capitation and contributions based on income. On the other hand, internal funding is the method of how different health-care services are purchased or reimbursed. This becomes a rather hot topic in light of new trends for integrated and networked care to patients and different types of budgeting. Another dominating question in the German health-care system is the liberalization of the contractual law, with its "joint and uniform" regulations that have to be loosened for competition gains. After a discussion of the consequences of diagnosis-related groups (DRGs) in Germany, the article is concluded by a note on the political rationality of the current health-care reform for increased competition within the Statutory Health Insurance and its players as exemplified by the health fund. To sum up, it has to be said that the complexity and specific features of how the German system is financed seem to require ongoing reform considerations even after realization of the currently debated health-care reform law which, unfortunately, is dominated by political rationalities rather than objective thoughts.

  17. Developing a prenatal nursing care International Classification for Nursing Practice catalogue.

    Science.gov (United States)

    Liu, L; Coenen, A; Tao, H; Jansen, K R; Jiang, A L

    2017-09-01

    This study aimed to develop a prenatal nursing care catalogue of International Classification for Nursing Practice. As a programme of the International Council of Nurses, International Classification for Nursing Practice aims to support standardized electronic nursing documentation and facilitate collection of comparable nursing data across settings. This initiative enables the study of relationships among nursing diagnoses, nursing interventions and nursing outcomes for best practice, healthcare management decisions, and policy development. The catalogues are usually focused on target populations. Pregnant women are the nursing population addressed in this project. According to the guidelines for catalogue development, three research steps have been adopted: (a) identifying relevant nursing diagnoses, interventions and outcomes; (b) developing a conceptual framework for the catalogue; (c) expert's validation. This project established a prenatal nursing care catalogue with 228 terms in total, including 69 nursing diagnosis, 92 nursing interventions and 67 nursing outcomes, among them, 57 nursing terms were newly developed. All terms in the catalogue were organized by a framework with two main categories, i.e. Expected Changes of Pregnancy and Pregnancy at Risk. Each category had four domains, representing the physical, psychological, behavioral and environmental perspectives of nursing practice. This catalogue can ease the documentation workload among prenatal care nurses, and facilitate storage and retrieval of standardized data for many purposes, such as quality improvement, administration decision-support and researches. The documentations of prenatal care provided data that can be more fluently communicated, compared and evaluated across various healthcare providers and clinic settings. © 2016 International Council of Nurses.

  18. Conflict of interest in online point-of-care clinical support websites.

    Science.gov (United States)

    Amber, Kyle T; Dhiman, Gaurav; Goodman, Kenneth W

    2014-08-01

    Point-of-care evidence-based medicine websites allow physicians to answer clinical queries using recent evidence at the bedside. Despite significant research into the function, usability and effectiveness of these programmes, little attention has been paid to their ethical issues. As many of these sites summarise the literature and provide recommendations, we sought to assess the role of conflicts of interest in two widely used websites: UpToDate and Dynamed. We recorded all conflicts of interest for six articles detailing treatment for the following conditions: erectile dysfunction, fibromyalgia, hypogonadism, psoriasis, rheumatoid arthritis and Crohn's disease. These diseases were chosen as their medical management is either controversial, or they are treated using biological drugs which are mostly available by brand name only. Thus, we hypothesised that the role of conflict of interest would be more significant in these conditions than in an illness treated with generic medications or by strict guidelines. All articles from the UpToDate articles demonstrated a conflict of interest. At times, the editor and author would have a financial relationship with a company whose drug was mentioned within the article. This is in contrast with articles on the Dynamed website, in which no author or editor had a documented conflict. We offer recommendations regarding the role of conflict of interest disclosure in these point-of-care evidence-based medicine websites. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. NIH-IEEE 2015 Strategic Conference on Healthcare Innovations and Point-of-Care Technologies for Prec

    Science.gov (United States)

    NIH and the Institute for Electrical and Electronics Engineering, Engineering in Medicine and Biology Society (IEEE/EMBS) hosted the third iteration of the Healthcare Innovations and Point-of-Care Technologies Conference last week.

  20. Internal Medicine Residents' Beliefs, Attitudes, and Experiences Relating to Palliative Care: A Qualitative Study.

    Science.gov (United States)

    Kawaguchi, S; Mirza, R; Nissim, R; Ridley, J

    2017-05-01

    Internal medicine residents are frequently called upon to provide palliative care to hospitalized patients, but report feeling unprepared to do so effectively. Curricular development to enhance residents' palliative care skills and competencies requires an understanding of current beliefs, attitudes and learning priorities. We conducted a qualitative study consisting of semi-structured interviews with ten internal medicine residents to explore their understanding of and experiences with palliative care. All of the residents interviewed had a sound theoretical understanding of palliative care, but faced many challenges in being able to provide care in practice. The challenges described by residents were system-related, patient-related and provider-related. They identified several priority areas for further learning, and discussed ways in which their current education in palliative care could be enhanced. Our findings provide important insights to guide curricular development for internal medicine trainees. The top five learning priorities in palliative care that residents identified in our study were: 1) knowing how and when to initiate a palliative approach, 2) improving communication skills, 3) improving symptom management skills, 4) identifying available resources, and 5) understanding the importance of palliative care. Residents felt that their education in palliative care could be improved by having a mandatory rotation in palliative care, more frequent didactic teaching sessions, more case-based teaching from palliative care providers, opportunities to be directly observed, and increased support from palliative care providers after-hours.

  1. [Internal audit--the foundation of healthcare quality management in health care].

    Science.gov (United States)

    Smiianov, V A

    2014-01-01

    The paper proved the need for internal audit as the basis for quality control of medical care in a health facility, developed the project milestones and explains what needs to be taken into account at every stage during its implementation.

  2. Hematological clozapine monitoring with a point-of-care device: A randomized cross-over trial

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Thode, Dorrit; Stenager, Elsebeth

    for several reasons, perhaps most importantly because of the mandatory hematological monitoring. The Chempaq Express Blood Counter (Chempaq XBC) is a point-of-care device providing counts of white blood cells (WBC) and granulocytes based on a capillary blood sampling. A randomized cross-over trial design...

  3. Development of an International School Nurse Asthma Care Coordination Model

    Science.gov (United States)

    Garwick, Ann W.; Svavarsdóttir, Erla Kolbrun; Seppelt, Ann M.; Looman, Wendy S.; Anderson, Lori S.; Örlygsdóttir, Brynja

    2015-01-01

    Aim To identify and compare how school nurses in Reykjavik, Iceland and St. Paul, Minnesota coordinated care for youth with asthma (ages 10–18) and to develop an asthma school nurse care coordination model. Background Little is known about how school nurses coordinate care for youth with asthma in different countries. Design A qualitative descriptive study design using focus group data. Methods Six focus groups with 32 school nurses were conducted in Reykjavik (n=17) and St. Paul (n=15) using the same protocol between September 2008 – January 2009. Descriptive content analytic and constant comparison strategies were used to categorize and compare how school nurses coordinated care, which resulted in the development of an International School Nurse Asthma Care Coordination Model. Findings Participants in both countries spontaneously described a similar asthma care coordination process that involved information gathering, assessing risk for asthma episodes, prioritizing health care needs and anticipating and planning for student needs at the individual and school levels. This process informed how they individualized symptom management, case management and/or asthma education. School nurses played a pivotal part in collaborating with families, school and health care professionals to ensure quality care for youth with asthma. Conclusions Results indicate a high level of complexity in school nurses’ approaches to asthma care coordination that were responsive to the diverse and changing needs of students in school settings. The conceptual model derived provides a framework for investigators to use in examining the asthma care coordination process of school nurses in other geographic locations. PMID:25223389

  4. [Patient safety in home care - A review of international recommendations].

    Science.gov (United States)

    Czakert, Judith; Lehmann, Yvonne; Ewers, Michael

    2018-06-08

    In recent years there has been a growing trend towards nursing care at home in general as well as towards intensive home care being provided by specialized home care services in Germany. However, resulting challenges for patient safety have rarely been considered. Against this background we aimed to explore whether international recommendations for patient safety in home care in general and in intensive home care in particular already exist and how they can stimulate further practice development in Germany. A review of online English documents containing recommendations for patient safety in intensive home care was conducted. Available documents were analyzed and compared in terms of their form and content. Overall, a small number of relevant documents could be identified. None of these documents exclusively refer to the intensive home care sector. Despite their differences, however, the analysis of four selected documents showed similarities, e. g., regarding specific topics of patient safety (communication, involvement of patients and their relatives, risk assessment, medication management, qualification). Furthermore, strengths and weaknesses of the documents became apparent: e. g., an explicit understanding of patient safety, a literature-based introduction to safety topics or an adaptation of the recommendations to the specific features of home care were occasionally lacking. This document analysis provides interesting input to the formal and content-related development of specific recommendations and to practice development in Germany to improve patient safety in home care. Copyright © 2018. Published by Elsevier GmbH.

  5. Product qualification: a barrier to point-of-care microfluidic-based diagnostics?

    Science.gov (United States)

    Tantra, Ratna; van Heeren, Henne

    2013-06-21

    One of the most exciting applications of microfluidics-based diagnostics is its potential use in next generation point-of-care (POC) devices. Many prototypes are already in existence, but, as of yet, few have achieved commercialisation. In this article, we consider the issue surrounding product qualification as a potential barrier to market success. The study discusses, in the context of POC microfluidics-based diagnostics, what the generic issues are and potential solutions. Our findings underline the need for a community-based effort that is necessary to speed up the product qualification process.

  6. Parents' Perceptions of Primary Health Care Physiotherapy With Preterm Infants: Normalization, Clarity, and Trust.

    Science.gov (United States)

    Håkstad, Ragnhild B; Obstfelder, Aud; Øberg, Gunn Kristin

    2016-08-01

    Having a preterm infant is a life-altering event for parents. The use of interventions intended to support the parents is recommended. In this study, we investigated how parents' perceptions of physiotherapy in primary health care influenced their adaptation to caring for a preterm child. We conducted 17 interviews involving parents of seven infants, at infants' corrected age (CA) 3, 6, and 12 months. The analysis was a systematic text condensation, connecting to theory of participatory sense-making. The parents described a progression toward a new normalcy in the setting of persistent uncertainty. Physiotherapists can ameliorate this uncertainty and support the parents' progression toward normalization, by providing knowledge and acknowledging both the child as subject and the parent-child relationship. Via embodied interaction and the exploration of their child's capacity, the parents learn about their children's individuality and gain the confidence necessary to support and care for their children in everyday life. © The Author(s) 2015.

  7. Updating the International Standards for Tuberculosis Care. Entering the era of molecular diagnostics.

    Science.gov (United States)

    Hopewell, Philip C; Fair, Elizabeth L; Uplekar, Mukund

    2014-03-01

    The International Standards for Tuberculosis Care, first published in 2006 (Lancet Infect Dis 2006;6:710-725.) with a second edition in 2009 ( www.currytbcenter.ucsf.edu/international/istc_report ), was produced by an international coalition of organizations funded by the United States Agency for International Development. Development of the document was led jointly by the World Health Organization and the American Thoracic Society, with the aim of promoting engagement of all care providers, especially those in the private sector in low- and middle-income countries, in delivering high-quality services for tuberculosis. In keeping with World Health Organization recommendations regarding rapid molecular testing, as well as other pertinent new recommendations, the third edition of the Standards has been developed. After decades of dormancy, the technology available for tuberculosis care and control is now rapidly evolving. In particular, rapid molecular testing, using devices with excellent performance characteristics for detecting Mycobacterium tuberculosis and rifampin resistance, and that are practical and affordable for use in decentralized facilities in low-resource settings, is being widely deployed globally. Used appropriately, both within tuberculosis control programs and in private laboratories, these devices have the potential to revolutionize tuberculosis care and control, providing a confirmed diagnosis and a determination of rifampin resistance within a few hours, enabling appropriate treatment to be initiated promptly. Major changes have been made in the standards for diagnosis. Additional important changes include: emphasis on the recognition of groups at increased risk of tuberculosis; updating the standard on antiretroviral treatment in persons with tuberculosis and human immunodeficiency virus infection; and revising the standard on treating multiple drug-resistant tuberculosis.

  8. Normal limits of the electrocardiogram derived from a large database of Brazilian primary care patients.

    Science.gov (United States)

    Palhares, Daniel M F; Marcolino, Milena S; Santos, Thales M M; da Silva, José L P; Gomes, Paulo R; Ribeiro, Leonardo B; Macfarlane, Peter W; Ribeiro, Antonio L P

    2017-06-13

    Knowledge of the normal limits of the electrocardiogram (ECG) is mandatory for establishing which patients have abnormal ECGs. No studies have assessed the reference standards for a Latin American population. Our aim was to establish the normal ranges of the ECG for pediatric and adult Brazilian primary care patients. This retrospective observational study assessed all the consecutive 12-lead digital electrocardiograms of primary care patients at least 1 year old in Minas Gerais state, Brazil, recorded between 2010 and 2015. ECGs were excluded if there were technical problems, selected abnormalities were present or patients with selected self-declared comorbidities or on drug therapy. Only the first ECG from patients with multiple ECGs was accepted. The University of Glasgow ECG analysis program was used to automatically interpret the ECGs. For each variable, the 1st, 2nd, 50th, 98th and 99th percentiles were determined and results were compared to selected studies. A total of 1,493,905 ECGs were recorded. 1,007,891 were excluded and 486.014 were analyzed. This large study provided normal values for heart rate, P, QRS and T frontal axis, P and QRS overall duration, PR and QT overall intervals and QTc corrected by Hodges, Bazett, Fridericia and Framingham formulae. Overall, the results were similar to those from other studies performed in different populations but there were differences in extreme ages and specific measurements. This study has provided reference values for Latinos of both sexes older than 1 year. Our results are comparable to studies performed in different populations.

  9. The Karen instruments for measuring quality of nursing care: construct validity and internal consistency.

    Science.gov (United States)

    Lindgren, Margareta; Andersson, Inger S

    2011-06-01

    Valid and reliable instruments for measuring the quality of care are needed for evaluation and improvement of nursing care. Previously developed and evaluated instruments, the Karen-patient and the Karen-personnel based on Donabedian's Structure-Process-Outcome triad (S-P-O triad) had promising content validity, discriminative power and internal consistency. The objective of this study was to further develop the instruments with regard to construct validity and internal consistency. This prospective study was carried out in medical and surgical wards at a hospital in Sweden. A total of 95 patients and 120 personnel were included. The instruments were tested for construct validity by performing factor analyses in two steps and for internal consistency using Cronbach's alpha coefficient. The first confirmatory factor analyses, with a pre-determined three-factor solution did not load well according to the S-P-O triad, but the second exploratory factor analysis with a six-factor solution appeared to be more coherent and the distribution of variables seemed to be logical. The reliability, i.e. internal consistency, was good in both factor analyses. The Karen-patient and the Karen-personnel instruments have achieved acceptable levels of construct validity. The internal consistency of the instruments is good. This indicates that the instruments may be suitable to use in clinical practice for measuring the quality of nursing care.

  10. Connected, low-cost point-of-care diagnostics for rural South African clinics

    CSIR Research Space (South Africa)

    Smith, Suzanne

    2017-10-01

    Full Text Available sensors, Paper-based sensors, Radio frequency identification, Point-of-care diagnostics INTRODUCTION Data connectivity is an imperative consideration in the development of new POC diagnostic devices, particularly in the developing world [1... healthcare information standards. A low-cost color detector was implemented for use with existing lateral flow devices (LFDs) utilizing an RFID sensing chip (SL900A-DK-STQFN16, ams, Aus- tria), green light-emitting diode (LED), and photodetector (SFH...

  11. Acute nursing care of the older adult with fragility hip fracture: An international perspective (Part 2)

    LENUS (Irish Health Repository)

    Maher, Ann Butler

    2012-10-23

    The second part of this paper provides those who care for orthopaedic patients with evidence-supported international perspectives about acute nursing care of the older adult with fragility hip fracture. Developed by an international group of nurse experts and guided by a range of information from research and clinical practice, it focuses on nurse sensitive quality indicators during the acute hospitalisation for fragility hip fracture. Optimal care for the patient who has experienced such a fracture is the focus. This includes (in the first, earlier, part):\\r\

  12. Point-of-care outcome assessment in the cancer clinic: Audit of data quality

    International Nuclear Information System (INIS)

    Wong, Karen; Huang, Shao Hui; O'Sullivan, Brian; Lockwood, Gina; Dale, Darlene; Michaelson, Terry; Waldron, John; Bayley, Andrew; Cummings, Bernard; Dawson, Laura A.; Kim, John; Liu, Geoffrey; Ringash, Jolie

    2010-01-01

    Background and purpose: To assess the completeness and accuracy of stage and outcome data in the Anthology of Outcomes (AOs), a prospective point-of-care physician-collected electronic data system for patients at Princess Margaret Hospital. Material and methods: A random sample of 10% of the AO cases registered between July 2003 and December 2005 was drawn. An audit was conducted of the AO data compared with chart review and cancer registry. Results: The AO system was applied first to a head and neck (HN) cancer patient cohort. From 1152 HN cases, 120 were audited. TNM stage was recorded in all cases. Discrepancy was found between the AO and primary data sources in 3-13% of cases. Physician review showed a 3% error rate in overall stage recorded in the AO. Sixty-two outcomes in 43 patients were found on chart review. No outcomes were incorrectly recorded in the AO. Nineteen (31%) outcomes in 17 patients were missed in the AO. Conclusions: Our experience has demonstrated the feasibility of real-time outcome recording at point-of-care. New processes needed to improve the completeness of capture of patient outcomes in the AO have more recently been introduced. This successful system has been expanded to other disease sites.

  13. Impact of HbA1c Testing at Point of Care on Diabetes Management

    Science.gov (United States)

    Schnell, Oliver; Crocker, J. Benjamin; Weng, Jianping

    2016-01-01

    Diabetes is a highly prevalent disease also implicated in the development of several other serious complications like cardiovascular or renal disease. HbA1c testing is a vital step for effective diabetes management, however, given the low compliance to testing frequency and, commonly, a subsequent delay in the corresponding treatment modification, HbA1c at the point of care (POC) offers an opportunity for improvement of diabetes care. In this review, based on data from 1999 to 2016, we summarize the evidence supporting a further implementation of HbA1c testing at POC, discuss its limitations and propose recommendations for further development. PMID:27898388

  14. 5th International Conference on Advancements of Medicine and Health Care through Technology

    CERN Document Server

    Roman, Nicolae

    2017-01-01

    This volume presents the contributions of the fifth International Conference on Advancements of Medicine and Health Care through Technology (Meditech 2016), held in in Cluj-Napoka, Romania. The papers of this Proceedings volume present new developments in - Health Care Technology, - Medical Devices, Measurement and Instrumentation, - Medical Imaging, Image and Signal Processing, - Modeling and Simulation, - Molecular Bioengineering, - Biomechanics.

  15. Evaluation of new indigenous "point-of-care" ABO and Rh grouping device.

    Science.gov (United States)

    Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad

    2018-01-01

    Erycard 2.0 is a "point-of-care" device that is primarily being used for patient blood grouping before transfusion. Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. Erycard 2.0 can be used as "point-of-care" device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.

  16. A Novel Molecular Test to Diagnose Canine Visceral Leishmaniasis at the Point of Care

    Science.gov (United States)

    Castellanos-Gonzalez, Alejandro; Saldarriaga, Omar A.; Tartaglino, Lilian; Gacek, Rosana; Temple, Elissa; Sparks, Hayley; Melby, Peter C.; Travi, Bruno L.

    2015-01-01

    Dogs are the principal reservoir hosts of zoonotic visceral leishmaniasis (VL) but current serological methods are not sensitive enough to detect all subclinically infected animals, which is crucial to VL control programs. Polymerase chain reaction (PCR) methods have greater sensitivity but require expensive equipment and trained personnel, impairing its implementation in endemic areas. We developed a diagnostic test that uses isothermal recombinase polymerase amplification (RPA) to detect Leishmania infantum. This method was coupled with lateral flow (LF) reading with the naked eye to be adapted as a point-of-care test. The L. infantum RPA-LF had an analytical sensitivity similar to real time-PCR, detecting DNA of 0.1 parasites spiked in dog blood, which was equivalent to 40 parasites/mL. There was no cross amplification with dog or human DNA or with Leishmania braziliensis, Leishmania amazonensis, or Trypanosoma cruzi. The test also amplified Leishmania donovani strains (N = 7). In a group of clinically normal dogs (N = 30), RPA-LF detected more subclinical infections than rK39 strip test, a standard serological method (50% versus 13.3% positivity, respectively; P = 0.005). Also, RPA-LF detected L. infantum in noninvasive mucosal samples of dogs with a sensitivity comparable to blood samples. This novel molecular test may have a positive impact in leishmaniasis control programs. PMID:26240156

  17. 3D Printing and Assay Development for Point-of-Care Applications

    Science.gov (United States)

    Jagadeesh, Shreesha

    Existing centralized labs do not serve patients adequately in remote areas. To enable universal timely healthcare, there is a need to develop low cost, portable systems that can diagnose multiple disease (Point-of-Care (POC) devices). Future POC diagnostics can be more multi-functional if medical device vendors can develop interoperability standards. This thesis developed the following medical diagnostic modules: Plasma from 25 microl blood was extracted through a filter membrane to demonstrate a 3D printed sample preparation module. Sepsis biomarker, C - reactive protein, was quantified through adsorption on nylon beads to demonstrate bead-based assay suitable for 3D printed disposable cartridge module. Finally, a modular fluorescent detection kit was built using 3D printed parts to detect CD4 cells in a disposable cartridge from ChipCare Corp. Due to the modularity enabled by 3D printing technique, the developed units can be easily adapted to detect other diseases.

  18. Transfer from point-of-care Ultrasonography training to diagnostic performance on patients--a randomized controlled trial

    DEFF Research Database (Denmark)

    Todsen, Tobias; Jensen, Morten Lind; Tolsgaard, Martin Grønnebæk

    2016-01-01

    BACKGROUND: Clinicians are increasingly using point-of-care ultrasonography for bedside examinations of patients. However, proper training is needed in this technique, and it is unknown whether the skills learned from focused Ultrasonography courses are being transferred to diagnostic performance...... test and binary logistic regression, respectively. RESULTS: There was a significant difference in the performance score between the intervention group (27.4%) and the control group (18.0%, P = .004) and the diagnostic accuracy between the intervention group (65%) and the control group (39%, P = .014......). CONCLUSIONS: Clinicians could successfully transfer learning from an Ultrasonography course to improve diagnostic performance on patients. However, our results also indicate a need for more training when new technologies such as point-of-care ultrasonography are introduced....

  19. Metacognitive factors that impact student nurse use of point of care technology in clinical settings.

    Science.gov (United States)

    Kuiper, RuthAnne

    2010-01-01

    The utility of personal digital assistants (PDA) as a point of care resource in health care practice and education presents new challenges for nursing faculty. While there is a plethora of PDA resources available, little is known about the variables that effect student learning and technology adoption. In this study nursing students used PDA software programs which included a drug guide, medical dictionary, laboratory manual and nursing diagnosis manual during acute care clinical experiences. Analysis of student journals comparative reflective statements about the PDA as an adjunct to other available resources in clinical practice are presented. The benefits of having a PDA included readily available data, validation of thinking processes, and facilitation of care plan re-evaluation. Students reported increased frequency of use and independence. Significant correlations between user perceptions and computer self-efficacy suggested greater confidence in abilities with technology resulting in increased self-awareness and achievement of learning outcomes.

  20. Optical biosensor technologies for molecular diagnostics at the point-of-care

    Science.gov (United States)

    Schotter, Joerg; Schrittwieser, Stefan; Muellner, Paul; Melnik, Eva; Hainberger, Rainer; Koppitsch, Guenther; Schrank, Franz; Soulantika, Katerina; Lentijo-Mozo, Sergio; Pelaz, Beatriz; Parak, Wolfgang; Ludwig, Frank; Dieckhoff, Jan

    2015-05-01

    Label-free optical schemes for molecular biosensing hold a strong promise for point-of-care applications in medical research and diagnostics. Apart from diagnostic requirements in terms of sensitivity, specificity, and multiplexing capability, also other aspects such as ease of use and manufacturability have to be considered in order to pave the way to a practical implementation. We present integrated optical waveguide as well as magnetic nanoparticle based molecular biosensor concepts that address these aspects. The integrated optical waveguide devices are based on low-loss photonic wires made of silicon nitride deposited by a CMOS compatible plasma-enhanced chemical vapor deposition (PECVD) process that allows for backend integration of waveguides on optoelectronic CMOS chips. The molecular detection principle relies on evanescent wave sensing in the 0.85 μm wavelength regime by means of Mach-Zehnder interferometers, which enables on-chip integration of silicon photodiodes and, thus, the realization of system-on-chip solutions. Our nanoparticle-based approach is based on optical observation of the dynamic response of functionalized magneticcore/ noble-metal-shell nanorods (`nanoprobes') to an externally applied time-varying magnetic field. As target molecules specifically bind to the surface of the nanoprobes, the observed dynamics of the nanoprobes changes, and the concentration of target molecules in the sample solution can be quantified. This approach is suitable for dynamic real-time measurements and only requires minimal sample preparation, thus presenting a highly promising point-of-care diagnostic system. In this paper, we present a prototype of a diagnostic device suitable for highly automated sample analysis by our nanoparticle-based approach.

  1. "I Do Feel Like a Scientist at Times": A Qualitative Study of the Acceptability of Molecular Point-Of-Care Testing for Chlamydia and Gonorrhoea to Primary Care Professionals in a Remote High STI Burden Setting.

    Directory of Open Access Journals (Sweden)

    Lisa Natoli

    Full Text Available Point-of-care tests for chlamydia (CT and gonorrhoea (NG could increase the uptake and timeliness of testing and treatment, contribute to improved disease control and reduce reproductive morbidity. The GeneXpert (Xpert CT/NG assay, suited to use at the point-of-care, is being used in the TTANGO randomised controlled trial (RCT in 12 remote Australian health services with a high burden of sexually transmissible infections (STIs. This represents the first ever routine use of a molecular point-of-care diagnostic for STIs in primary care. The purpose of this study was to explore the acceptability of the GeneXpert to primary care staff in remote Australia.In-depth qualitative interviews were conducted with 16 staff (registered or enrolled nurses and Aboriginal Health Workers/Practitioners trained and experienced with GeneXpert testing. Interviews were digitally-recorded and transcribed verbatim prior to content analysis.Most participants displayed positive attitudes, indicating the test was both easy to use and useful in their clinical context. Participants indicated that point-of-care testing had improved management of STIs, resulting in more timely and targeted treatment, earlier commencement of partner notification, and reduced follow up efforts associated with client recall. Staff expressed confidence in point-of-care test results and treating patients on this basis, and reported greater job satisfaction. While point-of-care testing did not negatively impact on client flow, several found the manual documentation processes time consuming, suggesting that improved electronic connectivity and test result transfer between the GeneXpert and patient management systems could overcome this. Managing positive test results in a shorter time frame was challenging for some but most found it satisfying to complete episodes of care more quickly.In the context of a RCT, health professionals working in remote primary care in Australia found the GeneXpert highly

  2. Validation of the quantitative point-of-care CareStart biosensor for assessment of G6PD activity in venous blood.

    Directory of Open Access Journals (Sweden)

    Germana Bancone

    Full Text Available Glucose-6-phosphate dehydrogenase (G6PD deficiency is the most common enzymopathy in the human population affecting an estimated 8% of the world population, especially those living in areas of past and present malaria endemicity. Decreased G6PD enzymatic activity is associated with drug-induced hemolysis and increased risk of severe neonatal hyperbilirubinemia leading to brain damage. The G6PD gene is on the X chromosome therefore mutations cause enzymatic deficiency in hemizygote males and homozygote females while the majority of heterozygous females have an intermediate activity (between 30-80% of normal with a large distribution into the range of deficiency and normality. Current G6PD qualitative tests are unable to diagnose G6PD intermediate activities which could hinder wide use of 8-aminoquinolines for Plasmodium vivax elimination. The aim of the study was to assess the diagnostic performances of the new Carestart G6PD quantitative biosensor.A total of 150 samples of venous blood with G6PD deficient, intermediate and normal phenotypes were collected among healthy volunteers living along the north-western Thailand-Myanmar border. Samples were analyzed by complete blood count, by gold standard spectrophotometric assay using Trinity kits and by the latest model of Carestart G6PD biosensor which analyzes both G6PD and hemoglobin.Bland-Altman comparison of the CareStart normalized G6PD values to that of the gold standard assay showed a strong bias in values resulting in poor area under-the-curve values for both 30% and 80% thresholds. Performing a receiver operator curve identified threshold values for the CareStart product equivalent to the 30% and 80% gold standard values with good sensitivity and specificity values, 100% and 92% (for 30% G6PD activity and 92% and 94% (for 80% activity respectively.The Carestart G6PD biosensor represents a significant improvement for quantitative diagnosis of G6PD deficiency over previous versions. Further

  3. Early radiation changes of normal dog brain following internal and external brain irradiation: A preliminary report

    International Nuclear Information System (INIS)

    Chin, H.; Maruyama, Y.; Markesbery, W.; Goldstein, S.; Wang, P.; Tibbs, P.; Young, B.; Feola, J.; Beach, L.

    1984-01-01

    To examine radiation-induced changes in the normal brain, internal or external radiation was given to normal dog brain. Seven medium-sized dogs were used in this study. Two dogs were controls and an ice-pick (plastic implant applicator) was placed in the right frontal lobe for about 5 hours but no irradiation. Two dogs underwent Cs-137 brain implantation for 4 and 5 hours, respectively using an ice-pick technique. Two dogs were given internal neutron irradiation using the same technique of intracerebral ice-pick brachytherapy. One dog received an external photon irradiation using 6-Mev Linear Accelerator. Postmortem microscopic examination was made to study the early cerebral changes to irradiation in three dogs: one control with no irradiation; one received intracerebral Cesium implantation; and one external photon irradiation. Vascular change was the most prominent microscopic finding. There were hemorrhage, endothelial proliferation and fibrinoid changes of small vessel wall. Most of the changes were localized in the white matter and the cortex remained intact. Details (CT, NMR and histological studies) are discussed

  4. Infectious Disease Management through Point-of-Care Personalized Medicine Molecular Diagnostic Technologies

    Directory of Open Access Journals (Sweden)

    Luc Bissonnette

    2012-05-01

    Full Text Available Infectious disease management essentially consists in identifying the microbial cause(s of an infection, initiating if necessary antimicrobial therapy against microbes, and controlling host reactions to infection. In clinical microbiology, the turnaround time of the diagnostic cycle (>24 hours often leads to unnecessary suffering and deaths; approaches to relieve this burden include rapid diagnostic procedures and more efficient transmission or interpretation of molecular microbiology results. Although rapid nucleic acid-based diagnostic testing has demonstrated that it can impact on the transmission of hospital-acquired infections, we believe that such life-saving procedures should be performed closer to the patient, in dedicated 24/7 laboratories of healthcare institutions, or ideally at point of care. While personalized medicine generally aims at interrogating the genomic information of a patient, drug metabolism polymorphisms, for example, to guide drug choice and dosage, personalized medicine concepts are applicable in infectious diseases for the (rapid identification of a disease-causing microbe and determination of its antimicrobial resistance profile, to guide an appropriate antimicrobial treatment for the proper management of the patient. The implementation of point-of-care testing for infectious diseases will require acceptance by medical authorities, new technological and communication platforms, as well as reimbursement practices such that time- and life-saving procedures become available to the largest number of patients.

  5. Point-of-care technologies for molecular diagnostics using a drop of blood.

    Science.gov (United States)

    Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong

    2014-03-01

    Molecular diagnostics is crucial for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor and time intensive, expensive, and require highly trained operators. This review discusses the frontiers of point-of-care (POC) diagnostic technologies using a drop of blood obtained from a finger prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system.

    Science.gov (United States)

    Cao, Jing; Edwards, Rachel; Chairez, Janette; Devaraj, Sridevi

    2017-12-01

    Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

  7. Development of an International School Nurse Asthma Care Coordination Model.

    Science.gov (United States)

    Garwick, Ann W; Svavarsdóttir, Erla Kolbrun; Seppelt, Ann M; Looman, Wendy S; Anderson, Lori S; Örlygsdóttir, Brynja

    2015-03-01

    To identify and compare how school nurses in Reykjavik, Iceland and St. Paul, Minnesota coordinated care for youth with asthma (ages 10-18) and to develop an asthma school nurse care coordination model. Little is known about how school nurses coordinate care for youth with asthma in different countries. A qualitative descriptive study design using focus group data. Six focus groups with 32 school nurses were conducted in Reykjavik (n = 17) and St. Paul (n = 15) using the same protocol between September 2008 and January 2009. Descriptive content analytic and constant comparison strategies were used to categorize and compare how school nurses coordinated care, which resulted in the development of an International School Nurse Asthma Care Coordination Model. Participants in both countries spontaneously described a similar asthma care coordination process that involved information gathering, assessing risk for asthma episodes, prioritizing healthcare needs and anticipating and planning for student needs at the individual and school levels. This process informed how they individualized symptom management, case management and/or asthma education. School nurses played a pivotal part in collaborating with families, school and healthcare professionals to ensure quality care for youth with asthma. Results indicate a high level of complexity in school nurses' approaches to asthma care coordination that were responsive to the diverse and changing needs of students in school settings. The conceptual model derived provides a framework for investigators to use in examining the asthma care coordination process of school nurses in other geographic locations. © 2014 John Wiley & Sons Ltd.

  8. Physician Perspectives on Palliative Care for Children With Neuroblastoma: An International Context.

    Science.gov (United States)

    Balkin, Emily M; Thompson, Daria; Colson, K Ellicott; Lam, Catherine G; Matthay, Katherine K

    2016-05-01

    Studies have shown that children with cancer globally lack access to palliative care. Little is known regarding physicians' perceptions of palliative care, treatment access, and self-reported competence in providing palliative care. Members of the Global Neuroblastoma Network (online tumor board) were surveyed. Eighty-three respondents met inclusion criteria; 53 (64%) completed the survey. Most respondents trained in high-income countries (HIC) but practice in low- and middle-income countries (LMIC), and care for more than five patients with neuroblastoma annually. WHO Essential Medicines in palliative care varied in availability, with incomplete access across LMIC centers. Nonpharmacologic therapies were inconsistently available. Contrary to international definitions, 17% of respondents inappropriately considered palliative care as that initiated only after curative therapy is stopped. Mean physician competence composite score (Likert scale 1-5, 5 = very competent) in providing symptomatic relief and palliative care across phases of care was 2.93 (95% CI 2.71-3.22). Physicians reported significantly greater competence in symptom management during cure-directed therapy than during end-of-life (P = 0.02) or when patients are actively dying (P = 0.007). Practicing in HIC, prior palliative care training, having access to radiotherapy, and not having to turn patients away due to bed shortages were significantly predictive of perceived competence in providing palliative care at end of life. An international sample identified gaps in treatment and palliative care service availability, in understanding the definition of palliative care, and in self-reported competence in providing palliative care. Increased perceived competence was associated with training, which supports the need for increased palliative care education and advocacy, especially in LMIC. © 2016 Wiley Periodicals, Inc.

  9. Awareness, Interest, and Preferences of Primary Care Providers in Using Point-of-Care Cancer Screening Technology.

    Directory of Open Access Journals (Sweden)

    Chloe S Kim

    Full Text Available Well-developed point-of-care (POC cancer screening tools have the potential to provide better cancer care to patients in both developed and developing countries. However, new medical technology will not be adopted by medical providers unless it addresses a population's existing needs and end-users' preferences. The goals of our study were to assess primary care providers' level of awareness, interest, and preferences in using POC cancer screening technology in their practice and to provide guidelines to biomedical engineers for future POC technology development. A total of 350 primary care providers completed a one-time self-administered online survey, which took approximately 10 minutes to complete. A $50 Amazon gift card was given as an honorarium for the first 100 respondents to encourage participation. The description of POC cancer screening technology was provided in the beginning of the survey to ensure all participants had a basic understanding of what constitutes POC technology. More than half of the participants (57% stated that they heard of the term "POC technology" for the first time when they took the survey. However, almost all of the participants (97% stated they were either "very interested" (68% or "somewhat interested" (29% in using POC cancer screening technology in their practice. Demographic characteristics such as the length of being in the practice of medicine, the percentage of patients on Medicaid, and the average number of patients per day were not shown to be associated with the level of interest in using POC. These data show that there is a great interest in POC cancer screening technology utilization among this population of primary care providers and vast room for future investigations to further understand the interest and preferences in using POC cancer technology in practice. Ensuring that the benefits of new technology outweigh the costs will maximize the likelihood it will be used by medical providers and

  10. Use of electronic healthcare records in large-scale simple randomized trials at the point of care for the documentation of value-based medicine.

    Science.gov (United States)

    van Staa, T-P; Klungel, O; Smeeth, L

    2014-06-01

    A solid foundation of evidence of the effects of an intervention is a prerequisite of evidence-based medicine. The best source of such evidence is considered to be randomized trials, which are able to avoid confounding. However, they may not always estimate effectiveness in clinical practice. Databases that collate anonymized electronic health records (EHRs) from different clinical centres have been widely used for many years in observational studies. Randomized point-of-care trials have been initiated recently to recruit and follow patients using the data from EHR databases. In this review, we describe how EHR databases can be used for conducting large-scale simple trials and discuss the advantages and disadvantages of their use. © 2014 The Association for the Publication of the Journal of Internal Medicine.

  11. History of the international societies in health technology assessment: International Society for Technology Assessment in Health Care and Health Technology Assessment International.

    Science.gov (United States)

    Banta, David; Jonsson, Egon; Childs, Paul

    2009-07-01

    The International Society for Technology Assessment in Health Care (ISTAHC) was formed in 1985. It grew out of the increasing awareness of the international dimensions of health technology assessment (HTA) and the need for new communication methods at the international level. The main function of ISTAHC was to present an annual conference, which gradually grew in size, and also to generally improve in quality from to year. ISTAHC overextended itself financially early in the first decade of the 2000s and had to cease its existence. A new society, Health Technology Assessment international (HTAi), based on many of the same ideas and people, grew up beginning in the year 2003. The two societies have played a large role in making the field of HTA visible to people around the world and providing a forum for discussion on the methods and role of HTA.

  12. Clinicians' interpretations of point of care urine culture versus laboratory culture results: analysis from the four-country POETIC trial of diagnosis of uncomplicated urinary tract infection in primary care.

    Science.gov (United States)

    Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C

    2017-08-01

    Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. The clinical and economic impact of point-of-care CD4 testing in mozambique and other resource-limited settings: a cost-effectiveness analysis.

    Directory of Open Access Journals (Sweden)

    Emily P Hyle

    2014-09-01

    Full Text Available Point-of-care CD4 tests at HIV diagnosis could improve linkage to care in resource-limited settings. Our objective is to evaluate the clinical and economic impact of point-of-care CD4 tests compared to laboratory-based tests in Mozambique.We use a validated model of HIV testing, linkage, and treatment (CEPAC-International to examine two strategies of immunological staging in Mozambique: (1 laboratory-based CD4 testing (LAB-CD4 and (2 point-of-care CD4 testing (POC-CD4. Model outcomes include 5-y survival, life expectancy, lifetime costs, and incremental cost-effectiveness ratios (ICERs. Input parameters include linkage to care (LAB-CD4, 34%; POC-CD4, 61%, probability of correctly detecting antiretroviral therapy (ART eligibility (sensitivity: LAB-CD4, 100%; POC-CD4, 90% or ART ineligibility (specificity: LAB-CD4, 100%; POC-CD4, 85%, and test cost (LAB-CD4, US$10; POC-CD4, US$24. In sensitivity analyses, we vary POC-CD4-specific parameters, as well as cohort and setting parameters to reflect a range of scenarios in sub-Saharan Africa. We consider ICERs less than three times the per capita gross domestic product in Mozambique (US$570 to be cost-effective, and ICERs less than one times the per capita gross domestic product in Mozambique to be very cost-effective. Projected 5-y survival in HIV-infected persons with LAB-CD4 is 60.9% (95% CI, 60.9%-61.0%, increasing to 65.0% (95% CI, 64.9%-65.1% with POC-CD4. Discounted life expectancy and per person lifetime costs with LAB-CD4 are 9.6 y (95% CI, 9.6-9.6 y and US$2,440 (95% CI, US$2,440-US$2,450 and increase with POC-CD4 to 10.3 y (95% CI, 10.3-10.3 y and US$2,800 (95% CI, US$2,790-US$2,800; the ICER of POC-CD4 compared to LAB-CD4 is US$500/year of life saved (YLS (95% CI, US$480-US$520/YLS. POC-CD4 improves clinical outcomes and remains near the very cost-effective threshold in sensitivity analyses, even if point-of-care CD4 tests have lower sensitivity/specificity and higher cost than published

  14. An international point source outbreak of typhoid fever: a European collaborative investigation*

    Science.gov (United States)

    Stanwell-Smith, R. E.; Ward, L. R.

    1986-01-01

    A point source outbreak of Salmonella typhi, degraded Vi-strain 22, affecting 32 British visitors to Kos, Greece, in 1983 was attributed by a case—control study to the consumption of a salad at one hotel. This represents the first major outbreak of typhoid fever in which a salad has been identified as the vehicle. The source of the infection was probably a carrier in the hotel staff. The investigation demonstrates the importance of national surveillance, international cooperation, and epidemiological methods in the investigation and control of major outbreaks of infection. PMID:3488842

  15. Recommendations From the International Consortium on Professional Nursing Practice in Long-Term Care Homes.

    Science.gov (United States)

    McGilton, Katherine S; Bowers, Barbara J; Heath, Hazel; Shannon, Kay; Dellefield, Mary Ellen; Prentice, Dawn; Siegel, Elena O; Meyer, Julienne; Chu, Charlene H; Ploeg, Jenny; Boscart, Veronique M; Corazzini, Kirsten N; Anderson, Ruth A; Mueller, Christine A

    2016-02-01

    In response to the International Association of Gerontology and Geriatrics' global agenda for clinical research and quality of care in long-term care homes (LTCHs), the International Consortium on Professional Nursing Practice in Long Term Care Homes (the Consortium) was formed to develop nursing leadership capacity and address the concerns regarding the current state of professional nursing practice in LTCHs. At its invitational, 2-day inaugural meeting, the Consortium brought together international nurse experts to explore the potential of registered nurses (RNs) who work as supervisors or charge nurses within the LTCHs and the value of their contribution in nursing homes, consider what RN competencies might be needed, discuss effective educational (curriculum and practice) experiences, health care policy, and human resources planning requirements, and to identify what sustainable nurse leadership strategies and models might enhance the effectiveness of RNs in improving resident, family, and staff outcomes. The Consortium made recommendations about the following priority issues for action: (1) define the competencies of RNs required to care for older adults in LTCHs; (2) create an LTCH environment in which the RN role is differentiated from other team members and RNs can practice to their full scope; and (3) prepare RN leaders to operate effectively in person-centered care LTCH environments. In addition to clear recommendations for practice, the Consortium identified several areas in which further research is needed. The Consortium advocated for a research agenda that emphasizes an international coordination of research efforts to explore similar issues, the pursuit of examining the impact of nursing and organizational models, and the showcasing of excellence in nursing practice in care homes, so that others might learn from what works. Several studies already under way are also described. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care

  16. How to measure the international development of palliative care? A critique and discussion of current approaches.

    Science.gov (United States)

    Loucka, Martin; Payne, Sheila; Brearley, Sarah

    2014-01-01

    A number of research projects have been conducted that aim to gather data on the international development of palliative care. These data are important for policy makers and palliative care advocates. The aim of this article was to provide a critical comparative analysis of methodological approaches used to assess the development and status of palliative care services and infrastructure at an international level. A selective literature review that focused on the methodological features of eight identified reports was undertaken. Reviewed reports were found to differ in adopted methodologies and provided uneven amounts of methodological information. Five major methodological limitations were identified (lack of theory, use of experts as source of information, grey literature, difficulties in ranking, and the problematic nature of data on service provision). A set of recommendations on how to deal with these issues in future research is provided. Measuring the international development of palliative care is a difficult and challenging task. The results of this study could be used to improve the validity of future research in this field. Copyright © 2014 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.

  17. Clinicians' interpretations of point of care urine culture versus laboratory culture results : Analysis from the four-country POETIC trial of diagnosis of uncomplicated urinary tract infection in primary care

    NARCIS (Netherlands)

    Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J.M.; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A.; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C.

    2017-01-01

    Background. Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care.  Objective. To identify the degree to which clinicians'

  18. Evaluating Laboratory Performance on Point-of-Care Glucose Testing with Six Sigma Metric for 151 Institutions in China.

    Science.gov (United States)

    Fei, Yang; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-10-01

    The aim of this study was to use Six Sigma(SM) (Motorola Trademark Holdings, Libertyville, IL) techniques to analyze the quality of point-of-care (POC) glucose testing measurements quantitatively and to provide suggestions for improvement. In total, 151 laboratories in China were included in this investigation in 2014. Bias and coefficient of variation were collected from an external quality assessment and an internal quality control program, respectively, for POC glucose testing organized by the National Center for Clinical Laboratories. The σ values and the Quality Goal Index were used to evaluate the performance of POC glucose meters. There were 27, 30, 57, and 37 participants in the groups using Optium Xceed™ (Abbott Diabetes Care, Alameda, CA), Accu-Chek(®) Performa (Roche, Basel, Switzerland), One Touch Ultra(®) (Abbott), and "other" meters, respectively. The median of the absolute value of percentage difference varied among different lots and different groups. Among all the groups, the Abbott One Touch Ultra group had the smallest median of absolute value of percentage difference except for lot 201411, whereas the "other" group had the largest median in all five lots. More than 85% of participate laboratories satisfied the total allowable error (TEa) requirement in International Organization for Standardization standard 15197:2013, and 85.43% (129/151) of laboratories obtained intralaboratory coefficient of variations less than 1/3TEa. However, Six Sigma techniques suggested that 41.72% (63/151) to 65.56% (99/151) of the laboratories needed to improve their POC glucose testing performance, in either precision, trueness, or both. Laboratories should pay more attention on the practice of POC glucose testing and take actions to improve their performance. Only in this way can POC glucose testing really function well in clinical practice.

  19. Rapid Point-of-Care Diagnostic Test for Syphilis in High-Risk Populations, Manaus, Brazil

    OpenAIRE

    Sabid?, Meritxell; Benzaken, Adele S.; de Andrade Rodrigues, ?nio Jos?; Mayaud, Philippe

    2009-01-01

    : We assessed the acceptability and operational suitability of a rapid point-of-care syphilis test and identified barriers to testing among high-risk groups and healthcare professionals in a sexually transmitted infections clinic in Manaus, Brazil. Use of this test could considerably alleviate the impact of syphilis in hard-to-reach populations in the Amazon region of Brazil.

  20. Development of discrete choice model considering internal reference points and their effects in travel mode choice context

    Science.gov (United States)

    Sarif; Kurauchi, Shinya; Yoshii, Toshio

    2017-06-01

    In the conventional travel behavior models such as logit and probit, decision makers are assumed to conduct the absolute evaluations on the attributes of the choice alternatives. On the other hand, many researchers in cognitive psychology and marketing science have been suggesting that the perceptions of attributes are characterized by the benchmark called “reference points” and the relative evaluations based on them are often employed in various choice situations. Therefore, this study developed a travel behavior model based on the mental accounting theory in which the internal reference points are explicitly considered. A questionnaire survey about the shopping trip to the CBD in Matsuyama city was conducted, and then the roles of reference points in travel mode choice contexts were investigated. The result showed that the goodness-of-fit of the developed model was higher than that of the conventional model, indicating that the internal reference points might play the major roles in the choice of travel mode. Also shown was that the respondents seem to utilize various reference points: some tend to adopt the lowest fuel price they have experienced, others employ fare price they feel in perceptions of the travel cost.

  1. “I Do Feel Like a Scientist at Times”: A Qualitative Study of the Acceptability of Molecular Point-Of-Care Testing for Chlamydia and Gonorrhoea to Primary Care Professionals in a Remote High STI Burden Setting

    Science.gov (United States)

    Natoli, Lisa; Guy, Rebecca J.; Shephard, Mark; Causer, Louise; Badman, Steven G.; Hengel, Belinda; Tangey, Annie; Ward, James; Coburn, Tony; Anderson, David; Kaldor, John; Maher, Lisa

    2015-01-01

    Background Point-of-care tests for chlamydia (CT) and gonorrhoea (NG) could increase the uptake and timeliness of testing and treatment, contribute to improved disease control and reduce reproductive morbidity. The GeneXpert (Xpert CT/NG assay), suited to use at the point-of-care, is being used in the TTANGO randomised controlled trial (RCT) in 12 remote Australian health services with a high burden of sexually transmissible infections (STIs). This represents the first ever routine use of a molecular point-of-care diagnostic for STIs in primary care. The purpose of this study was to explore the acceptability of the GeneXpert to primary care staff in remote Australia. Methods In-depth qualitative interviews were conducted with 16 staff (registered or enrolled nurses and Aboriginal Health Workers/Practitioners) trained and experienced with GeneXpert testing. Interviews were digitally-recorded and transcribed verbatim prior to content analysis. Results Most participants displayed positive attitudes, indicating the test was both easy to use and useful in their clinical context. Participants indicated that point-of-care testing had improved management of STIs, resulting in more timely and targeted treatment, earlier commencement of partner notification, and reduced follow up efforts associated with client recall. Staff expressed confidence in point-of-care test results and treating patients on this basis, and reported greater job satisfaction. While point-of-care testing did not negatively impact on client flow, several found the manual documentation processes time consuming, suggesting that improved electronic connectivity and test result transfer between the GeneXpert and patient management systems could overcome this. Managing positive test results in a shorter time frame was challenging for some but most found it satisfying to complete episodes of care more quickly. Conclusions In the context of a RCT, health professionals working in remote primary care in Australia

  2. Sub-acute Tamponade and the Value of Point-of-Care Ultrasound for Rapid Diagnosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Daniel C. Kolinsky

    2017-07-01

    Full Text Available Minoxidil is a strong oral vasodilator that is used to treat patients with hypertension refractory to first-line medications. We report a case of minoxidil-associated subacute cardiac tamponade diagnosed by point-of-care ultrasound (POCUS in a hypertensive patient. A 30-year-old male with a past medical history of poorly controlled hypertension (treated with minoxidil and chronic kidney disease presented with 2–3 days of chest pain and shortness of breath with markedly elevated blood pressures. A point-of-care transthoracic echocardiogram revealed a massive pericardial effusion with sonographic tamponade physiology. We review the risk factors for developing pericardial effusions that progress to cardiac tamponade, the utility of diagnosing these patients by POCUS, and the incidence of patients who present with sonographic signs of cardiac tamponade without hypotension.

  3. Evaluation of the performance of a point-of-care method for total and differential white blood cell count in clozapine users.

    Science.gov (United States)

    Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H

    2016-12-01

    We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.

  4. The universe of ANA testing: a case for point-of-care ANA testing.

    Science.gov (United States)

    Konstantinov, Konstantin N; Rubin, Robert L

    2017-12-01

    Testing for total antinuclear antibodies (ANA) is a critical tool for diagnosis and management of autoimmune diseases at both the primary care and subspecialty settings. Repurposing of ANA from a test for lupus to a test for any autoimmune condition has driven the increase in ANA requests. Changes in ANA referral patterns include early or subclinical autoimmune disease detection in patients with low pre-test probability and use of negative ANA results to rule out underlying autoimmune disease. A positive result can lead to further diagnostic considerations. Currently, ANA tests are performed in centralized laboratories; an alternative would be ANA testing at the clinical point-of-care (POC). By virtue of its near real-time data collection capability, low cost, and ease of use, we believe the POC ANA has the potential to enable a new paradigm shift in autoimmune serology testing.

  5. A wearable point-of-care system for home use that incorporates plug-and-play and wireless standards.

    Science.gov (United States)

    Yao, Jianchu; Schmitz, Ryan; Warren, Steve

    2005-09-01

    A point-of-care system for continuous health monitoring should be wearable, easy to use, and affordable to promote patient independence and facilitate acceptance of new home healthcare technology. Reconfigurability, interoperability, and scalability are important. Standardization supports these requirements, and encourages an open market where lower product prices result from vendor competition. This paper first discusses candidate standards for wireless communication, plug-and-play device interoperability, and medical information exchange in point-of-care systems. It then addresses the design and implementation of a wearable, plug-and-play system for home care which adopts the IEEE 1073 Medical Information Bus (MIB) standards, and uses Bluetooth as the wireless communication protocol. This standards-based system maximizes user mobility by incorporating a three-level architecture populated by base stations, wearable data loggers, and wearable sensors. Design issues include the implementation of the MIB standards on microcontroller-driven embedded devices, low power consumption, wireless data exchange, and data storage and transmission in a reconfigurable body-area network.

  6. Research priorities in health economics and funding for palliative care: views of an international think tank.

    Science.gov (United States)

    Harding, Richard; Gomes, Barbara; Foley, Kathleen M; Higginson, Irene J

    2009-07-01

    At the conclusion of the November 2007 meeting, the assembled international expert group identified the research agenda. The adoption of this agenda would take forward health economic research in palliative care, and generate the necessary data for improved funding decision making, and resource allocation. Recommendations for study included international comparative research into the components of care and settings, evaluative studies, methodologic development and strategies to initiate studies, and make better use of data.

  7. 3D printed microfluidic mixer for point-of-care diagnosis of anemia.

    Science.gov (United States)

    Plevniak, Kimberly; Campbell, Matthew; Mei He

    2016-08-01

    3D printing has been an emerging fabrication tool in prototyping and manufacturing. We demonstrated a 3D microfluidic simulation guided computer design and 3D printer prototyping for quick turnaround development of microfluidic 3D mixers, which allows fast self-mixing of reagents with blood through capillary force. Combined with smartphone, the point-of-care diagnosis of anemia from finger-prick blood has been successfully implemented and showed consistent results with clinical measurements. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare.

  8. Normal probability plots with confidence.

    Science.gov (United States)

    Chantarangsi, Wanpen; Liu, Wei; Bretz, Frank; Kiatsupaibul, Seksan; Hayter, Anthony J; Wan, Fang

    2015-01-01

    Normal probability plots are widely used as a statistical tool for assessing whether an observed simple random sample is drawn from a normally distributed population. The users, however, have to judge subjectively, if no objective rule is provided, whether the plotted points fall close to a straight line. In this paper, we focus on how a normal probability plot can be augmented by intervals for all the points so that, if the population distribution is normal, then all the points should fall into the corresponding intervals simultaneously with probability 1-α. These simultaneous 1-α probability intervals provide therefore an objective mean to judge whether the plotted points fall close to the straight line: the plotted points fall close to the straight line if and only if all the points fall into the corresponding intervals. The powers of several normal probability plot based (graphical) tests and the most popular nongraphical Anderson-Darling and Shapiro-Wilk tests are compared by simulation. Based on this comparison, recommendations are given in Section 3 on which graphical tests should be used in what circumstances. An example is provided to illustrate the methods. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Normalization of US-Cuban Relations: Obama Doctrine and International Security in the Western Hemisphere

    Directory of Open Access Journals (Sweden)

    Piotr Łaciński

    2015-12-01

    Full Text Available Strained relations between the US and Cuba after the victory of the Cuban revolution were a permanent element of the destabilization of international security in the Western Hemisphere. During the Cold War, this destabilization was a function of the East-West confrontation. Since the end of Cold War the importance of Cuba as a Western Hemisphere entity hostile to the United States has diminished radically. Definite steps to normalize relations with Cuba have been taken only in 2014. The media named the change of policies of the US towards Cuba (and Iran as the Obama Doctrine. This article will try to prove that the continuation of the confron-tational and hostile US-Cuban relations after the collapse of the Eastern bloc was an exceptional and "unnatural" phenomenon from the perspective of realistic school of international relations, both for Washington and Havana.

  10. Home birth integration into the health care systems of eleven international jurisdictions.

    Science.gov (United States)

    Comeau, Amanda; Hutton, Eileen K; Simioni, Julia; Anvari, Ella; Bowen, Megan; Kruegar, Samantha; Darling, Elizabeth K

    2018-02-13

    The purpose of this study was to develop assessment criteria that could be used to examine the level of integration of home birth within larger health care systems in developed countries across 11 international jurisdictions. An expert panel developed criteria and a definition to assess home birth integration within health care systems. We selected jurisdictions based on the publications that were eligible for inclusion in our systematic review and meta-analysis on planned place of birth. We sent the authors of the included publications a questionnaire about home birth practitioners and practices in their respective health care system at the time of their studies. We searched published peer-reviewed, non-peer-reviewed, and gray literature, and the websites of professional bodies to document information about home birth integration in each jurisdiction based on our criteria. Where information was lacking, we contacted experts in the field from the relevant jurisdiction. Home birth is well integrated into the health care system in British Columbia (Canada), England, Iceland, the Netherlands, New Zealand, Ontario (Canada), and Washington State (USA). Home birth is less well integrated into the health care system in Australia, Japan, Norway, and Sweden. This paper is the first to propose criteria for the evaluation of home birth integration within larger maternity care systems. Application of these criteria across 11 international jurisdictions indicates differences in the recognition and training of home birth practitioners, in access to hospital facilities, and in the supplies and equipment available at home births, which give rise to variation in the level of integration across different settings. Standardized criteria for the evaluation of systems integration are essential for interpreting planned home birth outcomes that emerge from contextual differences. © 2018 Wiley Periodicals, Inc.

  11. Initiation of glucose-lowering treatment decreases international normalized ratio levels among users of vitamin K antagonists

    DEFF Research Database (Denmark)

    Stage, Tore Bjerregaard; Pottegård, Anton; Henriksen, Daniel Pilsgaard

    2016-01-01

    -lowering treatment affects international normalized ratio (INR) and dose requirements of the anticoagulant VKAs warfarin and phenprocoumon. PATIENTS/METHODS: We performed a self-controlled retrospective register-based study. A total of 118 patients initiating glucose-lowering treatment while being treated......-lowering treatment reduces the anticoagulant effect of VKA to an extent that is likely to be clinically relevant. This finding needs confirmation and mechanistic explanation. This article is protected by copyright. All rights reserved....

  12. Depression treatment for impoverished mothers by point-of-care providers: A randomized controlled trial.

    Science.gov (United States)

    Segre, Lisa S; Brock, Rebecca L; O'Hara, Michael W

    2015-04-01

    Depression in low-income, ethnic-minority women of childbearing age is prevalent and compromises infant and child development. Yet numerous barriers prevent treatment delivery. Listening Visits (LV), an empirically supported intervention developed for delivery by British home-visiting nurses, could address this unmet mental health need. This randomized controlled trial (RCT) evaluated the effectiveness of LV delivered at a woman's usual point-of-care, including home visits or an ob-gyn office. Listening Visits were delivered to depressed pregnant women or mothers of young children by their point-of-care provider (e.g., home visitor or physician's assistant), all of whom had low levels of prior counseling experience. Three quarters of the study's participants were low-income. Of those who reported ethnicity, all identified themselves as minorities. Participants from 4 study sites (N = 66) were randomized in a 2:1 ratio, to LV or a wait-list control group (WLC). Assessments, conducted at baseline and 8 weeks, evaluated depression, quality of life, and treatment satisfaction. Depressive severity, depressive symptoms, and quality of life significantly improved among LV recipients as compared with women receiving standard social/health services. Women valued LV as evidenced by their high attendance rates and treatment satisfaction ratings. In a stepped model of depression care, LV can provide an accessible, acceptable, and effective first-line treatment option for at-risk women who otherwise are unlikely to receive treatment. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  13. Internal marketing within a health care organization: developing an implementation plan.

    Science.gov (United States)

    Hallums, A

    1994-05-01

    This paper discusses how the concept of internal marketing can be applied within a health care organization. In order to achieve a market orientation an organization must identify the needs and wants of its customers and how these may change in the future. In order to achieve this, internal marketing is a necessary step to the implementation of the organizations marketing strategy. An outline plan for the introduction of an internal marketing programme within an acute hospital trust is proposed. The plan identifies those individuals and departments who should be involved in the planning and implementation of the programme. The benefits of internal marketing to the Trust are also considered.

  14. The Matrix Metalloproteinase 9 Point-of-Care Test in Dry Eye.

    Science.gov (United States)

    Lanza, Nicole L; Valenzuela, Felipe; Perez, Victor L; Galor, Anat

    2016-04-01

    Dry eye is a common, multifactorial disease currently diagnosed by a combination of symptoms and signs. However, the subjective symptoms of dry eye poorly correlate to the current gold standard for diagnostic tests, reflecting the need to develop better objective tests for the diagnosis of dry eye. This review considers the role of ocular surface matrix metalloproteinase 9 (MMP-9) in dry eye and the implications of a novel point-of-care test that measures MMP-9 levels, InflammaDry (RPS, Sarasota, FL) on choosing appropriate therapeutic treatments. Published by Elsevier Inc.

  15. Advances in point-of-care technologies for molecular diagnostics.

    Science.gov (United States)

    Zarei, Mohammad

    2017-12-15

    Advances in miniaturization, nanotechnology, and microfluidics, along with developments in cloud-connected point-of-care (POC) diagnostics technologies are pushing the frontiers of POC devices toward low-cost, user-friendly, and enhanced sensitivity molecular-level diagnostics. The combination of various bio-sensing platforms within smartphone-integrated electronic readers provides accurate on-site and on-time diagnostics based on various types of chemical and biological targets. Further, 3D printing technology shows a huge potential toward fabrication and improving the performance of POC devices. Integration of skin-like flexible sensors with wireless communication technology creates a unique opportunity for continuous, real-time monitoring of patients for both preventative healthcare and during disease outbreaks. Here, we review recent developments and advances in POC technologies and describe how these advances enhance the performance of POC platforms. Also, this review describes challenges, directions, and future trends on application of emerging technologies in POC diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. International Vision Care: Issues and Approaches.

    Science.gov (United States)

    Khanna, Rohit C; Marmamula, Srinivas; Rao, Gullapalli N

    2017-09-15

    Globally, 32.4 million individuals are blind and 191 million have moderate or severe visual impairment (MSVI); 80% of cases of blindness and MSVI are avoidable. However, great efforts are needed to tackle blindness and MSVI, as eye care in most places is delivered in isolation from and without significant integration with general health sectors. Success stories, including control of vitamin A deficiency, onchocerciasis, and trachoma, showed that global partnerships, multisectoral collaboration, public-private partnerships, corporate philanthropy, support from nongovernmental organizations-both local and international-and governments are responsible for the success of these programs. Hence, the World Health Organization's universal eye health global action plan for 2014-2019 has a goal of reducing the public health problem of blindness and ensuring access to comprehensive eye care; the plan aims to integrate eye health into health systems, thus providing universal eye health coverage (UEHC). This article discusses the challenges faced by low- and middle-income countries in strengthening the six building blocks of the health system. It discusses how the health systems in these countries need to be geared toward tackling the issues of emerging noncommunicable eye diseases, existing infectious diseases, and the common causes of blindness and visual impairment, such as cataract and refractive error. It also discusses how some of the comprehensive eye care models in the developing world have addressed these challenges. Moving ahead, if we are to achieve UEHC, we need to develop robust, sustainable, good-quality, comprehensive eye care programs throughout the world, focusing on the areas of greatest need. We also need to develop public health approaches for more complex problems such as diabetic retinopathy, glaucoma, childhood blindness, corneal blindness, and low vision. There is also a great need to train high-level human resources of all cadres in adequate numbers and

  17. Point-of-Care Hemoglobin/Hematocrit Testing: Comparison of Methodology and Technology.

    Science.gov (United States)

    Maslow, Andrew; Bert, Arthur; Singh, Arun; Sweeney, Joseph

    2016-04-01

    Point-of-care (POC) testing allows rapid assessment of hemoglobin (Hgb) and hematocrit (Hct) values. This study compared 3 POC testing devices--the Radical-7 pulse oximeter (Radical-7, Neuchȃtel, Switzerland), the i-STAT (Abbott Point of Care, Princeton, NJ), and the GEM 4000 (Instrumentation Laboratory, Bedford, MA)--to the hospital reference device, the UniCel DxH 800 (Beckman Coulter, Brea, CA) in cardiac surgery patients. Prospective study. Tertiary care cardiovascular center. Twenty-four consecutive elective adult cardiac surgery patients. Hgb and Hct values were measured using 3 POC devices (the Radical-7, i-STAT, and GEM 4000) and a reference laboratory device (UniCel DxH 800). Data were collected simultaneously before surgery, after heparin administration, after heparin reversal with protamine, and after sternal closure. Data were analyzed using bias analyses. POC testing data were compared with that of the reference laboratory device. Hgb levels ranged from 6.8 to 15.1 g/dL, and Hct levels ranged from 20.1% to 43.8%. The overall mean bias was lowest with the i-STAT (Hct, 0.22%; Hgb 0.05 g/dL) compared with the GEM 4000 (Hct, 2.15%; Hgb, 0.63 g/dL) and the Radical-7 (Hgb 1.16 g/dL). The range of data for the i-STAT and Radical-7 was larger than that with the GEM 4000, and the pattern or slopes changed significantly with the i-STAT and Radical-7, whereas that of the GEM 4000 remained relatively stable. The GEM 4000 demonstrated a consistent overestimation of laboratory data, which tended to improve after bypass and at lower Hct/Hgb levels. The i-STAT bias changed from overestimation to underestimation, the latter in the post-cardiopulmonary bypass period and at lower Hct/Hgb levels. By contrast, the Radical-7 biases increased during the surgical procedure and in the lower ranges of Hgb. Important clinical differences and limitations were found among the 3 POC testing devices that should caution clinicians from relying on these data as sole determinants of

  18. Evaluation of a pharmacist-managed lipid clinic that uses point-of-care lipid testing.

    Science.gov (United States)

    Gerrald, Katherine R; Dixon, Dave L; Barnette, Debra J; Williams, Virginia G

    2010-01-01

    Hyperlipidemia is a significant, modifiable risk factor for developing coronary heart disease. Low-density lipoprotein cholesterol (LDL-C) goal achievement has improved overall, but many high-risk patients remain above the desired LDL-C goals. Published data have demonstrated the ability of pharmacist-managed lipid clinics to improve lipid management in a variety of clinical settings. This observational analysis aimed to report the impact of a newly developed hospital-based, outpatient lipid clinic by the use of point-of-care testing on LDL-C goal attainment. A retrospective, observational analysis was conducted from February 2007 to December 2008. The primary outcome measure was the change in the proportion of patients who achieved their LDL-C goal at the end of the observation period compared with baseline. A total of 81 patients met study inclusion criteria. Mean duration of follow-up was 9.0 ± 4.9 (SD) months. At the end of the observation period, 82.9% of patients achieved their LDL-C goal compared with 55.3% at baseline (P used point-of-care testing to obtain lipid results for making therapy adjustments during the face-to-face visit. Copyright © 2010 National Lipid Association. Published by Elsevier Inc. All rights reserved.

  19. A critical analysis of the implementation of service user involvement in primary care research and health service development using normalization process theory.

    Science.gov (United States)

    Tierney, Edel; McEvoy, Rachel; O'Reilly-de Brún, Mary; de Brún, Tomas; Okonkwo, Ekaterina; Rooney, Michelle; Dowrick, Chris; Rogers, Anne; MacFarlane, Anne

    2016-06-01

    There have been recent important advances in conceptualizing and operationalizing involvement in health research and health-care service development. However, problems persist in the field that impact on the scope for meaningful involvement to become a routine - normalized - way of working in primary care. In this review, we focus on current practice to critically interrogate factors known to be relevant for normalization - definition, enrolment, enactment and appraisal. Ours was a multidisciplinary, interagency team, with community representation. We searched EBSCO host for papers from 2007 to 2011 and engaged in an iterative, reflexive approach to sampling, appraising and analysing the literature following the principles of a critical interpretive synthesis approach and using Normalization Process Theory. Twenty-six papers were chosen from 289 papers, as a purposeful sample of work that is reported as service user involvement in the field. Few papers provided a clear working definition of service user involvement. The dominant identified rationale for enrolling service users in primary care projects was linked with policy imperatives for co-governance and emancipatory ideals. The majority of methodologies employed were standard health services research methods that do not qualify as research with service users. This indicates a lack of congruence between the stated aims and methods. Most studies only reported positive outcomes, raising questions about the balance or completeness of the published appraisals. To improve normalization of meaningful involvement in primary care, it is necessary to encourage explicit reporting of definitions, methodological innovation to enhance co-governance and dissemination of research processes and findings. © 2014 The Authors Health Expectations Published by John Wiley & Sons Ltd.

  20. Transnational spaces of care: migrant nurses in Norway.

    Science.gov (United States)

    Isaksen, Lise Widding

    2012-01-01

    This article argues that international nurse recruitment from Latvia to Norway is not a win–win situation. The gains and losses of nurse migration are unevenly distributed between sender and receiver countries. On the basis of empirical research and interviews with Latvian nurses and families they left behind, this article argues that nurse migration transforms families and communities and that national health services now become global workplaces. Some decades ago feminist research pointed to the fact that the welfare state was based on a male breadwinner family and women’s unpaid production of care work at home. Today this production of unpaid care is “outsourced” from richer to poorer countries and is related to an emergence of transnational spaces of care. International nurse recruitment and global nurse care chains in Norway increasingly provide the labor that prevents the new adult worker model and gender equality politics from being disrupted in times where families are overloaded with elder care loads.

  1. Improving and measuring inpatient documentation of medical care within the MS-DRG system: education, monitoring, and normalized case mix index.

    Science.gov (United States)

    Rosenbaum, Benjamin P; Lorenz, Robert R; Luther, Ralph B; Knowles-Ward, Lisa; Kelly, Dianne L; Weil, Robert J

    2014-01-01

    Documentation of the care delivered to hospitalized patients is a ubiquitous and important aspect of medical care. The majority of references to documentation and coding are based on the Centers for Medicare and Medicaid Services (CMS) Medicare Severity Diagnosis Related Group (MS-DRG) inpatient prospective payment system (IPPS). We educated the members of a clinical care team in a single department (neurosurgery) at our hospital. We measured subsequent documentation improvements in a simple, meaningful, and reproducible fashion. We created a new metric to measure documentation, termed the "normalized case mix index," that allows comparison of hospitalizations across multiple unrelated MS-DRG groups. Compared to one year earlier, the traditional case mix index, normalized case mix index, severity of illness, and risk of mortality increased one year after the educational intervention. We encourage other organizations to implement and systematically monitor documentation improvement efforts when attempting to determine the accuracy and quality of documentation achieved.

  2. Cortical fMRI activation to opponents' body kinematics in sport-related anticipation: expert-novice differences with normal and point-light video.

    Science.gov (United States)

    Wright, M J; Bishop, D T; Jackson, R C; Abernethy, B

    2011-08-18

    Badminton players of varying skill levels viewed normal and point-light video clips of opponents striking the shuttle towards the viewer; their task was to predict in which quadrant of the court the shuttle would land. In a whole-brain fMRI analysis we identified bilateral cortical networks sensitive to the anticipation task relative to control stimuli. This network is more extensive and localised than previously reported. Voxel clusters responding more strongly in experts than novices were associated with all task-sensitive areas, whereas voxels responding more strongly in novices were found outside these areas. Task-sensitive areas for normal and point-light video were very similar, whereas early visual areas responded differentially, indicating the primacy of kinematic information for sport-related anticipation. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. The relationship between individualized care and the practice environment: an international study.

    Science.gov (United States)

    Papastavrou, Evridiki; Acaroglu, Rengin; Sendir, Merdiye; Berg, Agneta; Efstathiou, Georgios; Idvall, Ewa; Kalafati, Maria; Katajisto, Jouko; Leino-Kilpi, Helena; Lemonidou, Chryssoula; da Luz, Maria Deolinda Antunes; Suhonen, Riitta

    2015-01-01

    Previous research studies have found that the better the quality of practice environments in hospitals, the better the outcomes for nurses and patients. Practice environment may influence nurses' ability to individualize care but the detailed relationship between individualized care and the professional practice environment has not been investigated widely. Some evidence exists about the association of practice environments with the level of individualization of nursing care, but this evidence is based on single national studies. The aim of this study was to determine whether nurses' views of their professional practice environment associate with their views of the level of care individualization in seven countries. This study had an international, multisite, prospective, cross-sectional, exploratory survey design. The study involved acute orthopedic and trauma surgical inpatient wards (n=91) in acute care hospitals (n=34) in seven countries, Cyprus, Finland, Greece, the State of Kansas, USA, Portugal, Sweden, and Turkey. Nurses (n=1163), registered or licensed practical, working in direct patient care, in orthopedic and trauma inpatient units in acute care hospitals in seven countries participated in the study. Self-administered questionnaires, including two instruments, the Revised Professional Practice Environment and the Individualized Care Scale-Nurse (Individualized Care Scale-Nurse A and B) were used for data collection. Data were analyzed statistically using descriptive statistics, simultaneous multiple regression analysis, and generalized linear model. Two regression models were applied to assess the predictive validity of the Revised Professional Practice Environment on the Individualized Care Scale-Nurse-A and B. The results showed that elements of the professional practice environment were associated with care individualization. Internal work motivation, cultural sensitivity, control over practice, teamwork, and staff relationship with physicians were

  4. Care in subsequent pregnancies following stillbirth: an international survey of parents.

    Science.gov (United States)

    Wojcieszek, A M; Boyle, F M; Belizán, J M; Cassidy, J; Cassidy, P; Erwich, Jjhm; Farrales, L; Gross, M M; Heazell, Aep; Leisher, S H; Mills, T; Murphy, M; Pettersson, K; Ravaldi, C; Ruidiaz, J; Siassakos, D; Silver, R M; Storey, C; Vannacci, A; Middleton, P; Ellwood, D; Flenady, V

    2018-01-01

    To assess the frequency of additional care, and parents' perceptions of quality, respectful care, in pregnancies subsequent to stillbirth. Multi-language web-based survey. International. A total of 2716 parents, from 40 high- and middle-income countries. Data were obtained from a broader survey of parents' experiences following stillbirth. Data were analysed using descriptive statistics and stratified by geographic region. Subgroup analyses explored variation in additional care by gestational age at index stillbirth. Frequency of additional care, and perceptions of quality, respectful care. The majority (66%) of parents conceived their subsequent pregnancy within 1 year of stillbirth. Additional antenatal care visits and ultrasound scans were provided for 67% and 70% of all parents, respectively, although there was wide variation across geographic regions. Care addressing psychosocial needs was less frequently provided, such as additional visits to a bereavement counsellor (10%) and access to named care provider's phone number (27%). Compared with parents whose stillbirth occurred at ≤ 29 weeks of gestation, parents whose stillbirth occurred at ≥ 30 weeks of gestation were more likely to receive various forms of additional care, particularly the option for early delivery after 37 weeks. Around half (47-63%) of all parents felt that elements of quality, respectful care were consistently applied, such as spending enough time with parents and involving parents in decision-making. Greater attention is required to providing thoughtful, empathic and collaborative care in all pregnancies following stillbirth. Specific education and training for health professionals is needed. More support for providing quality care in pregnancies after stillbirth is needed. Study rationale and design More than two million babies are stillborn every year. Most parents will conceive again soon after having a stillborn baby. These parents are more likely to have another stillborn baby in

  5. Predictive value of routine point-of-care cardiac troponin T measurement for prehospital diagnosis and risk-stratification in patients with suspected acute myocardial infarction

    DEFF Research Database (Denmark)

    Rasmussen, Martin B; Stengaard, Carsten; Sørensen, Jacob T

    2017-01-01

    -of-care cardiac troponin T measurements (11.0%) had a value ≥50 ng/l, including 966 with acute myocardial infarction (sensitivity: 44.2%, specificity: 92.8%). Patients presenting with a prehospital point-of-care cardiac troponin T value ≥50 ng/l had a one-year mortality of 24% compared with 4.8% in those...... with values analysis: point-of-care cardiac troponin T≥50 ng/l (hazard ratio 2.10, 95% confidence interval: 1.90-2.33), congestive heart failure (hazard ratio 1.93, 95% confidence interval: 1......OBJECTIVE: The purpose of this study was to determine the predictive value of routine prehospital point-of-care cardiac troponin T measurement for diagnosis and risk stratification of patients with suspected acute myocardial infarction. METHODS AND RESULTS: All prehospital emergency medical service...

  6. Point-of-care ultrasound education: the increasing role of simulation and multimedia resources.

    Science.gov (United States)

    Lewiss, Resa E; Hoffmann, Beatrice; Beaulieu, Yanick; Phelan, Mary Beth

    2014-01-01

    This article reviews the current technology, literature, teaching models, and methods associated with simulation-based point-of-care ultrasound training. Patient simulation appears particularly well suited for learning point-of-care ultrasound, which is a required core competency for emergency medicine and other specialties. Work hour limitations have reduced the opportunities for clinical practice, and simulation enables practicing a skill multiple times before it may be used on patients. Ultrasound simulators can be categorized into 2 groups: low and high fidelity. Low-fidelity simulators are usually static simulators, meaning that they have nonchanging anatomic examples for sonographic practice. Advantages are that the model may be reused over time, and some simulators can be homemade. High-fidelity simulators are usually high-tech and frequently consist of many computer-generated cases of virtual sonographic anatomy that can be scanned with a mock probe. This type of equipment is produced commercially and is more expensive. High-fidelity simulators provide students with an active and safe learning environment and make a reproducible standardized assessment of many different ultrasound cases possible. The advantages and disadvantages of using low- versus high-fidelity simulators are reviewed. An additional concept used in simulation-based ultrasound training is blended learning. Blended learning may include face-to-face or online learning often in combination with a learning management system. Increasingly, with simulation and Web-based learning technologies, tools are now available to medical educators for the standardization of both ultrasound skills training and competency assessment.

  7. Point-of-Care HIV Testing and Linkage in an Urban Cohort in the Southern US

    Directory of Open Access Journals (Sweden)

    Anne Zinski

    2013-01-01

    Full Text Available The Southern states experience the highest rates of HIV and AIDS in the US, and point-of-care (POC testing outside of primary care may contribute to status awareness in medically underserved populations in this region. To evaluate POC screening and linkage to care at an urban south site, analyses were performed on a dataset of 3,651 individuals from an integrated rapid-result HIV testing and linkage program to describe this test-seeking cohort and determine trends associated with screening, results, and linkage to care. Four percent of the population had positive results. We observed significant differences by test result for age, race and gender, reported risk behaviors, test location, and motivation for screening. The overall linkage rate was 86%, and we found significant differences for clients who were linked to HIV care versus persons whose linkage could not be confirmed with respect to race and gender, location, and motivation. The linkage rate for POC testing that included a comprehensive intake visit and colocated primary care services for in-state residents was 97%. Additional research on integrated POC screening and linkage methodologies that provide intake services at time of testing is essential for increasing status awareness and improving linkage to HIV care in the US.

  8. Miniaturization for Point-of-Care Analysis: Platform Technology for Almost Every Biomedical Assay.

    Science.gov (United States)

    Schumacher, Soeren; Sartorius, Dorian; Ehrentreich-Förster, Eva; Bier, Frank F

    2012-10-01

    Platform technologies for the changing need of diagnostics are one of the main challenges in medical device technology. From one point-of-view the demand for new and more versatile diagnostic is increasing due to a deeper knowledge of biomarkers and their combination with diseases. From another point-of-view a decentralization of diagnostics will occur since decisions can be made faster resulting in higher success of therapy. Hence, new types of technologies have to be established which enables a multiparameter analysis at the point-of-care. Within this review-like article a system called Fraunhofer ivD-platform is introduced. It consists of a credit-card sized cartridge with integrated reagents, sensors and pumps and a read-out/processing unit. Within the cartridge the assay runs fully automated within 15-20 minutes. Due to the open design of the platform different analyses such as antibody, serological or DNA-assays can be performed. Specific examples of these three different assay types are given to show the broad applicability of the system.

  9. Cost-effectiveness of point-of-care testing for dehydration in the pediatric ED.

    Science.gov (United States)

    Whitney, Rachel E; Santucci, Karen; Hsiao, Allen; Chen, Lei

    2016-08-01

    Acute gastroenteritis (AGE) and subsequent dehydration account for a large proportion of pediatric emergency department (PED) visits. Point-of-care (POC) testing has been used in conjunction with clinical assessment to determine the degree of dehydration. Despite the wide acceptance of POC testing, little formal cost-effective analysis of POC testing in the PED exists. We aim to examine the cost-effectiveness of using POC electrolyte testing vs traditional serum chemistry testing in the PED for children with AGE. This was a cost-effective analysis using data from a randomized control trial of children with AGE. A decision analysis model was constructed to calculate cost-savings from the point of view of the payer and the provider. We used parameters obtained from the trial, including cost of testing, admission rates, cost of admission, and length of stay. Sensitivity analyses were performed to evaluate the stability of our model. Using the data set of 225 subjects, POC testing results in a cost savings of $303.30 per patient compared with traditional serum testing from the point of the view of the payer. From the point-of-view of the provider, POC testing results in consistent mean savings of $36.32 ($8.29-$64.35) per patient. Sensitivity analyses demonstrated the stability of the model and consistent savings. This decision analysis provides evidence that POC testing in children with gastroenteritis-related moderate dehydration results in significant cost savings from the points of view of payers and providers compared to traditional serum chemistry testing. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Validation of Tuba1a as Appropriate Internal Control for Normalization of Gene Expression Analysis during Mouse Lung Development

    Directory of Open Access Journals (Sweden)

    Aditi Mehta

    2015-02-01

    Full Text Available The expression ratio between the analysed gene and an internal control gene is the most widely used normalization method for quantitative RT-PCR (qRT-PCR expression analysis. The ideal reference gene for a specific experiment is the one whose expression is not affected by the different experimental conditions tested. In this study, we validate the applicability of five commonly used reference genes during different stages of mouse lung development. The stability of expression of five different reference genes (Tuba1a, Actb Gapdh, Rn18S and Hist4h4 was calculated within five experimental groups using the statistical algorithm of geNorm software. Overall, Tuba1a showed the least variability in expression among the different stages of lung development, while Hist4h4 and Rn18S showed the maximum variability in their expression. Expression analysis of two lung specific markers, surfactant protein C (SftpC and Clara cell-specific 10 kDA protein (Scgb1a1, normalized to each of the five reference genes tested here, confirmed our results and showed that incorrect reference gene choice can lead to artefacts. Moreover, a combination of two internal controls for normalization of expression analysis during lung development will increase the accuracy and reliability of results.

  11. Influence of kidney function on risk of supratherapeutic international normalized ratio-related hemorrhage in warfarin users: a prospective cohort study

    Science.gov (United States)

    Background: Anticoagulation management is difficult in chronic kidney disease, with frequent supratherapeutic international normalized ratios (INRs >/= 4) increasing hemorrhagic risk. We evaluated whether the interaction of INR and lower estimated glomerular filtration rate (eGFR) increases hemorrha...

  12. ‘Reaching Out’: international models for transitional care for teenage and young adult cancer patients

    Directory of Open Access Journals (Sweden)

    Charlotte Weston

    2018-05-01

    Full Text Available Background: This article will give an overview of ‘Reaching Out’, a project to identify international models of transitional care for adolescent and young adult (AYA cancer patients. Aims: •\tExplore provision of AYA cancer care in a different cultural context •\tIdentify new models of care for supporting transition between paediatric, AYA and adult care, and between acute and primary care •\tIdentify relevant resources and service designs that could be adapted for use in AYA services in the UK Methods: Three-week observational visit in a range of international healthcare settings. Findings: Similarities and differences between Australian and UK healthcare systems were observed. Models of care using a range of resources, including structured health and wellbeing programmes, were identified to support transitional care. Models of collaborative working across organisations were observed. The implementation of innovative programmes to improve efficiency of services and limit unnecessary impact on patient time and finances were identified, including the use of Skype for collaborative consultations between acute and community healthcare providers. Conclusions: Recommendations to benefit AYA patients with an improved range of supportive, holistic services and improved person-centred care include: •\tJoint AYA nursing posts between AYA centres to support transition •\tStructured AYA post-treatment health and wellbeing programme •\tProgramme of creative wellbeing projects to support transition at the end of treatment Scope use of Skype appointments within the AYA service Implications for practice: Observing service provision and healthcare practice in an international setting provides the opportunity to improve cross-cultural competence, which is essential to culturally competent care. Cross-cultural competence supports the improvement of patient care through experiential learning, sharing of ideas and connecting with others. The

  13. The Value of Clinical Needs Assessments for Point-of-Care Diagnostics.

    Science.gov (United States)

    Weigl, Bernhard H; Gaydos, Charlotte A; Kost, Gerald; Beyette, Fred R; Sabourin, Stephanie; Rompalo, Anne; de Los Santos, Tala; McMullan, Jason T; Haller, John

    2012-06-01

    Most entrepreneurial ventures fail long before the core technology can be brought to the marketplace because of disconnects in performance and usability measures such as accuracy, cost, complexity, assay stability, and time requirements between technology developers' specifications and needs of the end-users. By going through a clinical needs assessment (CNA) process, developers will gain vital information and a clear focus that will help minimize the risks associated with the development of new technologies available for use within the health care system. This article summarizes best practices of the principal investigators of the National Institute of Biomedical Imaging and Bioengineering point-of-care (POC) centers within the National Institute of Biomedical Imaging and Bioengineering POC Technologies Research Network. Clinical needs assessments are particularly important for product development areas that do not sufficiently benefit from traditional market research, such as grant-funded research and development, new product lines using cutting-edge technologies developed in start-up companies, and products developed through product development partnerships for low-resource settings. The objectives of this article were to (1) highlight the importance of CNAs for development of POC devices, (2) discuss methods applied by POC Technologies Research Network for assessing clinical needs, and (3) provide a road map for future CNAs.

  14. The Value of Clinical Needs Assessments for Point-of-Care Diagnostics

    Science.gov (United States)

    Weigl, Bernhard H.; Gaydos, Charlotte A.; Kost, Gerald; Beyette, Fred R.; Sabourin, Stephanie; Rompalo, Anne; de los Santos, Tala; McMullan, Jason T.; Haller, John

    2013-01-01

    Most entrepreneurial ventures fail long before the core technology can be brought to the marketplace because of disconnects in performance and usability measures such as accuracy, cost, complexity, assay stability, and time requirements between technology developers’ specifications and needs of the end-users. By going through a clinical needs assessment (CNA) process, developers will gain vital information and a clear focus that will help minimize the risks associated with the development of new technologies available for use within the health care system. This article summarizes best practices of the principal investigators of the National Institute of Biomedical Imaging and Bioengineering point-of-care (POC) centers within the National Institute of Biomedical Imaging and Bioengineering POC Technologies Research Network. Clinical needs assessments are particularly important for product development areas that do not sufficiently benefit from traditional market research, such as grant-funded research and development, new product lines using cutting-edge technologies developed in start-up companies, and products developed through product development partnerships for low-resource settings. The objectives of this article were to (1) highlight the importance of CNAs for development of POC devices, (2) discuss methods applied by POC Technologies Research Network for assessing clinical needs, and (3) provide a road map for future CNAs. PMID:23935405

  15. Development and validation of a noncontact spectroscopic device for hemoglobin estimation at point-of-care

    Science.gov (United States)

    Sarkar, Probir Kumar; Pal, Sanchari; Polley, Nabarun; Aich, Rajarshi; Adhikari, Aniruddha; Halder, Animesh; Chakrabarti, Subhananda; Chakrabarti, Prantar; Pal, Samir Kumar

    2017-05-01

    Anemia severely and adversely affects human health and socioeconomic development. Measuring hemoglobin with the minimal involvement of human and financial resources has always been challenging. We describe a translational spectroscopic technique for noncontact hemoglobin measurement at low-resource point-of-care settings in human subjects, independent of their skin color, age, and sex, by measuring the optical spectrum of the blood flowing in the vascular bed of the bulbar conjunctiva. We developed software on the LabVIEW platform for automatic data acquisition and interpretation by nonexperts. The device is calibrated by comparing the differential absorbance of light of wavelength 576 and 600 nm with the clinical hemoglobin level of the subject. Our proposed method is consistent with the results obtained using the current gold standard, the automated hematology analyzer. The proposed noncontact optical device for hemoglobin estimation is highly efficient, inexpensive, feasible, and extremely useful in low-resource point-of-care settings. The device output correlates with the different degrees of anemia with absolute and trending accuracy similar to those of widely used invasive methods. Moreover, the device can instantaneously transmit the generated report to a medical expert through e-mail, text messaging, or mobile apps.

  16. Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications

    CSIR Research Space (South Africa)

    Smith, S

    2016-02-01

    Full Text Available Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and...

  17. Mentoring frontline managers: the vital force in stimulating innovation at the point of care.

    Science.gov (United States)

    Shiparski, Laurie; Authier, Philip

    2013-01-01

    Frontline managers in health care are the keepers of culture, the gateway to evoking a grass roots intelligence network, and they hold a pivotal role in advancing innovation at the point of care. Their roles are ever expanding and include knowledge and skills in managing the business, leading the people, and advancing their own leadership development. In all 3 areas, the impact of their leadership exponentially increases if they maximize innovative thinking and action. Health care executives need to establish the expectations for an innovative culture and the role of frontline managers. They must model the behaviors they promote and take the time to develop these frontline managers who are the hub for innovative success in the organization. This article offers insights and practical applications while exploring the innovation keystones of the following: creating an organizational culture of innovation, igniting collaboration that fuels diverse thinking and creativity, utilizing meaningful data to drive innovative decisions, and assessing and monitoring the ongoing climate and outcomes of innovation.

  18. Comparison of Dose When Prescribed to Point A and Point H for Brachytherapy in Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gang, Ji Hyeong; Gim, Il Hwan; Hwang, Seon Boong; Kim, Woong; Im, Hyeong Seo; Gang, Jin Mook; Gim, Gi Hwan; Lee, Ah Ram [Dept. of Radiation Oncology, Korea Institute of Radiological and Medical Sciences, Seou (Korea, Republic of)

    2012-09-15

    The purpose of this study is to compare plans prescribed to point A with these prescribed to point H recommended by ABS (American Brachytherapy Society) in high dose rate intracavitary brachytherapy for cervical carcinoma. This study selected 103 patients who received HDR (High Dose Rate) brachytherapy using tandem and ovoids from March 2010 to January 2012. Point A, bladder point, and rectal point conform with Manchester System. Point H conforms with ABS recommendation. Also Sigmoid colon point, and vagina point were established arbitrarily. We examined distance between point A and point H. The percent dose at point A was calculated when 100% dose was prescribed to point H. Additionally, the percent dose at each reference points when dose is prescribed to point H and point A were calculated. The relative dose at point A was lower when point H was located inferior to point A. The relative doses at bladder, rectal, sigmoid colon, and vagina points were higher when point H was located superior to point A, and lower when point H was located inferior to point A. This study found out that as point H got located much superior to point A, the absorbed dose of surrounding normal organs became higher, and as point H got located much inferior to point A, the absorbed dose of surrounding normal organs became lower. This differences dose not seem to affect the treatment. However, we suggest this new point is worth being considered for the treatment of HDR if dose distribution and absorbed dose at normal organs have large differences between prescribed to point A and H.

  19. International Practice in Care Provision for Post-stroke Visual Impairment.

    Science.gov (United States)

    Rowe, Fiona J

    2017-09-01

    This study sought to explore the practice of orthoptists internationally in care provision for poststroke visual impairment. Survey questions were developed and piloted with clinicians, academics, and users. Questions addressed types of visual problems, how these were identified, treated, and followed up, care pathways in use, links with other professions, and referral options. The survey was approved by the institutional ethical committee. The survey was accessed via a web link that was circulated through the International Orthoptic Association member professional organisations to orthoptists. Completed electronic surveys were obtained from 299 individuals. About one-third (35.5%) of orthoptists saw patients within 2 weeks of stroke onset and over half (55.5%) by 1 month post stroke. Stroke survivors were routinely assessed by 87%; over three-quarters in eye clinics. Screening tools were used by 11%. Validated tests were used for assessment of visual acuity (76.5%), visual field (68.2%), eye movement (80.9%), binocular vision (77.9%), and visual function (55.8%). Visual problems suspected by family or professionals were high (86.6%). Typical overall follow-up period of vision care was less than 3 months. Designated care pathways for stroke survivors with visual problems were used by 56.9% of orthoptists. Information on visual impairment was provided by 85.9% of orthoptists. In international orthoptic practice, there is general agreement on assessment and management of visual impairment in stroke populations. More than half of orthoptists reported seeing stroke survivors within 1 month of the stroke onset, typically in eye clinics. There was a high use of validated tests of visual acuity, visual fields, ocular motility, and binocular vision. Similarly there was high use of established treatment options including prisms, occlusion, compensatory strategies, and oculomotor training, appropriately targeted at specific types of visual conditions/symptoms. This

  20. Capacity building of nurses providing neonatal care in Rio de Janeiro, Brazil: methods for the POINTS of care project to enhance nursing education and reduce adverse neonatal outcomes

    Directory of Open Access Journals (Sweden)

    Darlow Brian A

    2012-03-01

    Full Text Available Abstract Background Increased survival of preterm infants in developing countries has often been accompanied by increased morbidity. A previous study found rates of severe retinopathy of prematurity varied widely between different neonatal units in Rio de Janeiro. Nurses have a key role in the care of high-risk infants but often do not have access to ongoing education programmes. We set out to design a quality improvement project that would provide nurses with the training and tools to decrease neonatal mortality and morbidity. The purpose of this report is to describe the methods and make the teaching package (POINTS of care--six modules addressing Pain control; optimal Oxygenation; Infection control; Nutrition interventions; Temperature control; Supportive care available to others. Methods/Design Six neonatal units, caring for 40% of preterm infants in Rio de Janeiro were invited to participate. In Phase 1 of the study multidisciplinary workshops were held in each neonatal unit to identify the neonatal morbidities of interest and to plan for data collection. In Phase 2 the teaching package was developed and tested. Phase 3 consisted of 12 months data collection utilizing a simple tick-sheet for recording. In Phase 4 (the Intervention all nurses were asked to complete all six modules of the POINTS of care package, which was supplemented by practical demonstrations. Phase 5 consisted of a further 12 months data collection. In Phase 1 it was agreed to include inborn infants with birthweight ≤ 1500 g or gestational age of ≤ 34 weeks. The primary outcome was death before discharge and secondary outcomes included retinopathy of prematurity and bronchopulmonary dysplasia. Assuming 400-450 infants in both pre- and post-intervention periods the study had 80% power at p = Discussion The results of the POINTS of Care intervention will be presented in a separate publication. Trial registration Current Controlled Trials: ISRCTN83110114

  1. Alterations in rotation thromboelastometry (ROTEM®) parameters: point-of-care testing vs analysis after pneumatic tube system transport.

    Science.gov (United States)

    Martin, J; Schuster, T; Moessmer, G; Kochs, E F; Wagner, K J

    2012-10-01

    Thromboelastometry as point-of-care (POC) testing enables the analysis of the clotting process at the bedside, providing rapid results to guide haemostatic therapy. However, POC testing utilizes medical staff who are managing critically ill patients, as non-laboratory personnel may not be sufficiently trained to run the devices. To resolve these problems, thromboelastometry can be performed in the central laboratory and rapid transport of samples can be accomplished via a pneumatic tube system (PTS). This study compares thromboelastometry parameters of blood samples analysed immediately with those analysed after PTS transport. In patients with normal haemostasis, two arterial blood samples were collected from each patient (n=92) in citrated plastic tubes to investigate the assays INTEM (n=35), EXTEM (n=27), and FIBTEM (n=30). One blood sample was analysed immediately, the other sample after PTS transport. Thromboelastometry was performed using a single ROTEM(®) device. The mean clot firmness values were significantly lower for PTS samples in both the INTEM (-0.7 mm cf. -1.1 mm) and EXTEM (-1.4 cf. -1.7 mm) assays. INTEM coagulation time (CT) was significantly lower in PTS samples with a mean difference of -13 s. EXTEM CT was significantly higher in PTS samples with a mean difference of +3.9 s. Thromboelastometry parameters of blood samples analysed after PTS transport are significantly altered compared with those analysed immediately. However, in patients with normal haemostasis, the alterations were small and without clinical consequence, implying that analysis after PTS transport is an acceptable alternative to prompt analysis at the bedside. Further studies should focus on patients with impaired haemostasis.

  2. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    Science.gov (United States)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  3. Development of indicators for patient care and monitoring standards for secondary health care services of Mumbai.

    Science.gov (United States)

    Malik, Seema S; D'Souza, Roshni Cynthia; Pashte, Pramod Mukund; Satoskar, Smita Manohar; D'Souza, Remilda Joyce

    2015-01-01

    The Qualitative aspect of health care delivery is one of the major factors in reducing morbidity and mortality in a health care setup. The expanding suburban secondary health care delivery facilities of the Municipal Corporation of Greater Mumbai are an important part of the healthcare backbone of Mumbai and therefore the quality of care delivered here needed standardization. The project was completed over a period of one year from Jan to Dec, 2013 and implemented in three phases. The framework with components and sub-components were developed and formats for data collection were standardized. The benchmarks were based on past performance in the same hospital and probability was used for development of normal range. An Excel spreadsheet was developed to facilitate data analysis. The indicators comprise of 3 components--Statutory Requirements, Patient care & Cure and Administrative efficiency. The measurements made, pointed to the broad areas needing attention. The Indicators for patient care and monitoring standards can be used as a self assessment tool for health care setups for standardization and improvement of delivery of health care services.

  4. Dew point, internal gas pressure, and chemical composition of the gas within the free volume of DWPF canistered waste forms

    International Nuclear Information System (INIS)

    Harbour, J.R.; Herman, D.T.; Crump, S.; Miller, T.J.; McIntosh, J.

    1996-01-01

    The Defense Waste Processing Facility (DWPF) produced 55 canistered waste forms containing simulated waste glass during the four Waste Qualification campaigns of the DWPF Startup Test Program. Testing of the gas within the free volume of these canisters for dew point, internal gas pressure, and chemical composition was performed as part of a continuing effort to demonstrate compliance with the Waste Acceptance Product Specifications. Results are presented for six glass-filled canisters. The dew points within the canisters met the acceptance criterion of < 20 degrees C for all six canisters. Factors influencing the magnitude of the dew point are presented. The chemical composition of the free volume gas was indistinguishable from air for all six canisters. Hence, no foreign materials were present in the gas phase of these canisters. The internal gas pressures within the sealed canisters were < 1 atm at 25 degrees C for all six canisters which readily met the acceptance criterion of an internal gas pressure of less than 1.5 atm at 25 degrees C. These results provided the evidence required to demonstrate compliance with the Waste Acceptance Product Specifications

  5. Nurse practitioners' focus on health care in terms of cure and care: analysis of graduate theses using the International Classification of Functioning, Disability and Health.

    Science.gov (United States)

    Stallinga, Hillegonda A; Jansen, Gerard J; Kastermans, Marijke C; Pranger, Albert; Dijkstra, Pieter U; Roodbol, Petrie F

    2016-07-01

    To explore the focus of nurse practitioners on health care in terms of cure and care. Nurse practitioners are expected to act on the intersection of cure and care. However, in clinical practice and education, a clear model covering this area is lacking; therefore, it is unknown to what extent nurse practitioners are focused on this specific area. Graduate theses may reflect the focus of nurse practitioners. Sequential exploratory mixed method. In total, 413 published abstracts of graduate theses of a Dutch Master of Advanced Nursing Practice (2000-2015) were analysed using the International Classification of Functioning, Disability and Health. Data source included aim, question and outcome of each thesis and graduates' characteristics. A qualitative deductive approach was used for the analyses. Theses were classified as focused on cure, care, or on the intersection of cure and care. A small majority of 53% (N = 219) of the graduate theses addressed patient's health status and could be classified in the International Classification of Functioning, Disability and Health. Of the classified theses, 48% were focused on cure, 39% on the intersection of cure and care and 13% on care. While the percentage of theses addressing health status increased significantly over the 15-year period, the percentage of theses focused on cure, care and on the intersection of cure and care remained the same. The graduate theses reflected that nurse practitioners are increasingly oriented towards patients' health status. However, their focus is predominantly on cure rather than on the intersection of cure and care. © 2016 John Wiley & Sons Ltd.

  6. Does Radar Technology Support the Diagnosis of Pneumothorax? PneumoScan—A Diagnostic Point-of-Care Tool

    Directory of Open Access Journals (Sweden)

    T. Lindner

    2013-01-01

    Full Text Available Background. A nonrecognized pneumothorax (PTX may become a life-threatening tension PTX. A reliable point-of-care diagnostic tool could help in reduce this risk. For this purpose, we investigated the feasibility of the use of the PneumoScan, an innovative device based on micropower impulse radar (MIR. Patients and Methods. addition to a standard diagnostic protocol including clinical examination, chest X-ray (CXR, and computed tomography (CT, 24 consecutive patients with chest trauma underwent PneumoScan testing in the shock trauma room to exclude a PTX. Results. The application of the PneumoScan was simple, quick, and reliable without functional disorder. Clinical examination and CXR each revealed one and PneumoScan three out of altogether four PTXs (sensitivity 75%, specificity 100%, positive predictive value 100%, and negative predictive value 95%. The undetected PTX did not require intervention. Conclusion. The PneumoScan as a point-of-care device offers additional diagnostic value in patient management following chest trauma. Further studies with more patients have to be performed to evaluate the diagnostic accuracy of the device.

  7. Calibrating care in midwifery : weighing the evidence on weight and weight gain for pregnant women

    NARCIS (Netherlands)

    Darie Daemers

    2017-01-01

    At the beginning of the twenty first century obesity entered Dutch maternity care as a ‘new illness’ challenging maternity care professionals in providing optimal care for women with higher BMI’s. International research revealed that obese women had more perinatal problems than normal weight women.

  8. "Una vida que no es normal": el contexto de los cuidados familiares en la demencia "A life that is not normal": the context of family care in dementia

    Directory of Open Access Journals (Sweden)

    Carmen de la Cuesta-Benjumea

    2011-06-01

    Full Text Available El grupo mayoritario de los cuidadores lo conforman mujeres que viven en situación de vulnerabilidad y cuentan con poco apoyo formal. Mientras que la bibliografía destaca los estudios sobre la carga del cuidado y cómo aliviarla, hay pocas investigaciones que describan las circunstancias donde se desarrollan estos cuidados. El propósito de este estudio cualitativo es describir el contexto en el que se desenvuelven los cuidados de familiares con demencia avanzada. Para las cuidadoras, su vida no es normal. Llevar una vida restringida y sin vida propia son categorías que describen el contexto de la vida de las cuidadoras. A esta clase de vida, las cuidadoras se han acostumbrado. Las enfermeras pueden mejorar esta situación, pueden aconsejar a los cuidadores para que reserven parcelas de vida propia, son además una voz autorizada para sensibilizar y fomentar prácticas equitativas en el cuidado familiar.The largest group of caregivers are women who live in situation of vulnerability and have little formal support. While research literature emphasises the burden of care and the relief of that burden, there are few studies that describe the context where this care takes place. The purpose of this qualitative study is to describe the context of dementia family care giving. For participants their life is not normal. Having a restricted life and without a proper life are the categories that describe care givers context. To this kind of life they are accustomed.Nurses can improve this situation. They can advice caregivers to reserve parcels of their persona life. Nurses are also authorized voices to promote and sensitize equitable family care practices.

  9. The Ebola Spatial Care Path™: Accelerating point-of-care diagnosis, decision making, and community resilience in outbreaks.

    Science.gov (United States)

    Kost, Gerald J; Ferguson, William J; Hoe, Jackie; Truong, Anh-Thu; Banpavichit, Arirat; Kongpila, Surin

    2015-01-01

    To present a vision where point-of-care testing (POCT) accelerates an Ebola Spatial Care Path™ (SCP) and future molecular diagnostics enable facilitated-access self-testing (FAST POC); to design an alternate care facility (ACF) for the SCP; to innovate an Ebola diagnostic center (DC); and to propel rapid POCT to the frontline to create resilience that stops future outbreaks. PubMed, literature, and web searches. Centers for Disease Control and Prevention (CDC), Food and Drug Administration (FDA), Medicine Without Frontiers, and World Health Organization (WHO) document analyses. Investigations in China, the Philippines, Thailand, and the United States. Review of SE Asia, US, and West Africa isolation-treatment centers. Innovation of a SCP, ACF, and DC suitable for American and other communities. The authors designed an ACF and DC to integrate SCP principles for urgent Ebola care. FDA emergency use authorizations for Ebola molecular diagnostics were discovered, but no portable, handheld, or self-contained molecular POC instruments are yet available, although feasible. The WHO initiated design criteria and an acceptance protocol for testing. Financial investment in POCT will downsize Ebola outbreaks. POCT is facilitating global health. Now, global health problems are elevating POCT to new levels of importance for accelerating diagnosis and evidence-based decision making during disease outbreaks. Authorities concur that rapid diagnosis has potential to stop disease spread. With embedded POCT, strategic SCPs planned by communities fulfill CDC recommendations. POC devices should consolidate multiplex test clusters supporting patients with Ebola in isolation. The ultimate future solution is FAST POC. New technologies offer minimally significant risks. Diagnostic centers in ACFs and transportable formats also will optimize Ebola SCPs.

  10. Practical challenges related to point of care testing.

    Science.gov (United States)

    Shaw, Julie L V

    2016-04-01

    Point of care testing (POCT) refers to laboratory testing that occurs near to the patient, often at the patient bedside. POCT can be advantageous in situations requiring rapid turnaround time of test results for clinical decision making. There are many challenges associated with POCT, mainly related to quality assurance. POCT is performed by clinical staff rather than laboratory trained individuals which can lead to errors resulting from a lack of understanding of the importance of quality control and quality assurance practices. POCT is usually more expensive than testing performed in the central laboratory and requires a significant amount of support from the laboratory to ensure the quality testing and meet accreditation requirements. Here, specific challenges related to POCT compliance with accreditation standards are discussed along with strategies that can be used to overcome these challenges. These areas include: documentation of POCT orders, charting of POCT results as well as training and certification of individuals performing POCT. Factors to consider when implementing connectivity between POCT instruments and the electronic medical record are also discussed in detail and include: uni-directional versus bidirectional communication, linking patient demographic information with POCT software, the importance of positive patient identification and considering where to chart POCT results in the electronic medical record.

  11. Pursuing Normality

    DEFF Research Database (Denmark)

    Madsen, Louise Sofia; Handberg, Charlotte

    2018-01-01

    implying an influence on whether to participate in cancer survivorship care programs. Because of "pursuing normality," 8 of 9 participants opted out of cancer survivorship care programming due to prospects of "being cured" and perceptions of cancer survivorship care as "a continuation of the disease......BACKGROUND: The present study explored the reflections on cancer survivorship care of lymphoma survivors in active treatment. Lymphoma survivors have survivorship care needs, yet their participation in cancer survivorship care programs is still reported as low. OBJECTIVE: The aim of this study...... was to understand the reflections on cancer survivorship care of lymphoma survivors to aid the future planning of cancer survivorship care and overcome barriers to participation. METHODS: Data were generated in a hematological ward during 4 months of ethnographic fieldwork, including participant observation and 46...

  12. Criteria required for an acceptable point-of-care test for UTI detection: Obtaining consensus using the Delphi technique.

    Science.gov (United States)

    Weir, Nichola-Jane M; Pattison, Sally H; Kearney, Paddy; Stafford, Bob; Gormley, Gerard J; Crockard, Martin A; Gilpin, Deirdre F; Tunney, Michael M; Hughes, Carmel M

    2018-01-01

    Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test.

  13. Community-Specific BMI Cutoff Points for South Indian Females

    Directory of Open Access Journals (Sweden)

    K. B. Kishore Mohan

    2011-01-01

    Full Text Available Objective. To analyze multiparameters related to total body composition, with specific emphasis on obesity in South Indian females, in order to derive community-specific BMI cutoff points. Patients and Methods. A total number of 87 females (of age 37.33±13.12 years from South Indian Chennai urban population participated in this clinical study. Body composition analysis and anthropometric measurements were acquired after conducting careful clinical examination. Results. BMI demonstrated high significance when normal group (21.02±1.47 kg/m2 was compared with obese group (29.31±3.95 kg/m2, <0.0001. BFM displayed high significance when normal group (14.92±4.28 kg was compared with obese group (29.94 ± 8.1 kg, <0.0001. Conclusion. Community-specific BMI cutoffs are necessary to assess obesity in different ethnic groups, and relying on WHO-based universal BMI cutoff points would be a wrong strategy.

  14. Point-of-care C-reactive protein testing to reduce inappropriate use of antibiotics for non-severe acute respiratory infections in Vietnamese primary health care: a randomised controlled trial.

    Science.gov (United States)

    Do, Nga T T; Ta, Ngan T D; Tran, Ninh T H; Than, Hung M; Vu, Bich T N; Hoang, Long B; van Doorn, H Rogier; Vu, Dung T V; Cals, Jochen W L; Chandna, Arjun; Lubell, Yoel; Nadjm, Behzad; Thwaites, Guy; Wolbers, Marcel; Nguyen, Kinh V; Wertheim, Heiman F L

    2016-09-01

    Inappropriate antibiotic use for acute respiratory tract infections is common in primary health care, but distinguishing serious from self-limiting infections is difficult, particularly in low-resource settings. We assessed whether C-reactive protein point-of-care testing can safely reduce antibiotic use in patients with non-severe acute respiratory tract infections in Vietnam. We did a multicentre open-label randomised controlled trial in ten primary health-care centres in northern Vietnam. Patients aged 1-65 years with at least one focal and one systemic symptom of acute respiratory tract infection were assigned 1:1 to receive either C-reactive protein point-of-care testing or routine care, following which antibiotic prescribing decisions were made. Patients with severe acute respiratory tract infection were excluded. Enrolled patients were reassessed on day 3, 4, or 5, and on day 14 a structured telephone interview was done blind to the intervention. Randomised assignments were concealed from prescribers and patients but not masked as the test result was used to assist treatment decisions. The primary outcome was antibiotic use within 14 days of follow-up. All analyses were prespecified in the protocol and the statistical analysis plan. All analyses were done on the intention-to-treat population and the analysis of the primary endpoint was repeated in the per-protocol population. This trial is registered under number NCT01918579. Between March 17, 2014, and July 3, 2015, 2037 patients (1028 children and 1009 adults) were enrolled and randomised. One adult patient withdrew immediately after randomisation. 1017 patients were assigned to receive C-reactive protein point-of-care testing, and 1019 patients were assigned to receive routine care. 115 patients in the C-reactive protein point-of-care group and 72 patients in the routine care group were excluded in the intention-to-treat analysis due to missing primary endpoint. The number of patients who used antibiotics

  15. Normal motor milestone development for use to promote child care

    Directory of Open Access Journals (Sweden)

    Mahdin A. Husaini

    2016-10-01

    Full Text Available Background Motor behavior is an essential aspect of child development, and usually assessed in terms of age of achievement of motor milestone. The early detection of infants experiencing subtle delays in motor maturation can allow early intervention in developmental problems. Intervention can be more effective if delays are identified early. In order to facilitate the identification of early delays, the Center of Nutrition and Foods Research and Development in Bogor has designed a simple tool to monitor the child (aged 3 to 18 months motor development. Objective To develop an observable of normal gross motor maturation for use to detect deviance or motor delay. Methods A total of 2100 healthy children, aged 3-18 months, from high socio-economic group, in urban and suburban areas, were studied. Body length, weight and motor development were measured on all children. Gross motor development was measured 17 pre selected milestones: lie, sit, crawl, creep, stand Mth assistance, walk with assistance, stand alone, walk alone, and run. Results There were no differences between males and females in the comparison of attainment motor maturation therefore a sex combined curve was developed. Conclusion The curve of normal motor milestone development can be used as a tool to evaluate motor development over time, and/or as a child development card for use in primary health care.

  16. The development of a point of care creatinine measurement using disposable ready to use microchip capillary electrophoresis

    NARCIS (Netherlands)

    Ávila Muñoz, Mónica; Eijkel, Jan C.T.; Floris, J.; Staal, S.S.; Ríos, Ángel; van den Berg, Albert

    2011-01-01

    We report on the determination of creatinine in human serum using a point-of-care device suitable for the use by untrained operators, the Medimate Multireader®. This device is based on electrophoretic separation and conductivity detection and its prefilled microfluidic chip has a single opening for

  17. WOMEN’S EVERYDAY LIFE EXPERIENCE OF HOUSEWORK AND CARE. BETWEEN PARTENERSHIP NORMS AND PATRIARCHAL NORMALITY

    OpenAIRE

    DIANA ELENA NEAGA

    2012-01-01

    My aim in this paper is to explore the process by which women from a Transylvanian county understand family relations in their everyday life with respect to the sharing of the household and care responsibilities among members, mostly men and women. In doing so I will use the distinction made by Martin Hollis between a normal behavior - which can arise after some roles have been performed (the patriarchal gender roles inside the family), and the normative behavior - the one with a moral value ...

  18. Internalized stigma as an independent risk factor for substance use problems among primary care patients: Rationale and preliminary support.

    Science.gov (United States)

    Kulesza, Magdalena; Watkins, Katherine E; Ober, Allison J; Osilla, Karen C; Ewing, Brett

    2017-11-01

    Little is known about internalized stigma among primary care patients, and whether the presence of internalized stigma is related to the severity of substance use problems independent of substance use-related variables. We sought to examine the relationship between internalized stigma and substance use problems among primary care patients with opioid or alcohol use disorders (OAUDs). We present baseline data from 393 primary care patients who were enrolled in a study of collaborative care for OAUDs. Regression analyses examined the relationship between internalized stigma and substance use problems, controlling for demographics, psychiatric comorbidity, and quantity/frequency of use. The majority of participants reported thinking, at least sometimes, that they "have permanently screwed up" their lives (60%), and felt "ashamed" (60%), and "out of place in the world" (51%) as a result of their opioid or alcohol use. Higher internalized stigma was significantly related to more substance use problems (β=2.68, p<0.01), even after the effects of covariates were accounted for. Stigma added 22%, out of 51% total variance explained, leading to a significant improvement in prediction of substance use problems. Among this group of primary care patients with OAUDs, rates of internalized stigma were comparable to those reported in specialty substance use treatment settings. Consistent with extant specialty care literature, our results suggest that internalized stigma may be a unique contributor that is associated with treatment outcomes, such as substance use problems, among primary care patients with OAUDs. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Institutional point-of-care glucometer identifies population trends in blood glucose associated with war.

    Science.gov (United States)

    Boaz, Mona; Matas, Zipora; Chaimy, Tova; Landau, Zohar; Bar Dayan, Yosefa; Berlovitz, Yitzhak; Wainstein, Julio

    2013-11-01

    Acute physiological stress has been shown to impair glucose homeostasis. War is a period of acute psychological stress, and its effect on glucose control is unknown. In this study random point-of-care (POC) glucose levels were measured using an automated, institutional glucometer in hospitalized adult patients prior to versus during the Israeli Pillar of Defense campaign (November 7-10, 2012). Random POC glucose values measured with the institutional blood glucose monitoring system were obtained 1 week prior to the Pillar of Defense campaign (November 7-10, 2012) and compared with values to those obtained during the first 4 days of the war (November 14-17, 2012). In total, 3,573 POC glucose measures were included: 1,865 during the pre-war period and 1,708 during the campaign. POC glucose measures were significantly higher during the war compared with the week preceding the war: 9.7±4.7 versus 9.3±4.2 mmol/L (P=0.02). In a general linear model, period (pre-war vs. during war) persisted as a significant predictor of POC glucose even after controlling for age, sex, and department type (internal medicine vs. surgical). Acute stress, such as a wartime situation, is associated with a significant increase in random blood glucose values in a population of hospitalized adults. Long-term follow-up of the individuals hospitalized during these two periods can reveal differences in morbidity and mortality trends.

  20. Gaps in monitoring during oral anticoagulation: insights into care transitions, monitoring barriers, and medication nonadherence.

    Science.gov (United States)

    Rose, Adam J; Miller, Donald R; Ozonoff, Al; Berlowitz, Dan R; Ash, Arlene S; Zhao, Shibei; Reisman, Joel I; Hylek, Elaine M

    2013-03-01

    Among patients receiving oral anticoagulation, a gap of > 56 days between international normalized ratio tests suggests loss to follow-up that could lead to poor anticoagulation control and serious adverse events. We studied long-term oral anticoagulation care for 56,490 patients aged 65 years and older at 100 sites of care in the Veterans Health Administration. We used the rate of gaps in monitoring per patient-year to predict percentage time in therapeutic range (TTR) at the 100 sites. Many patients (45%) had at least one gap in monitoring during an average of 1.6 years of observation; 5% had two or more gaps per year. The median gap duration was 74 days (interquartile range, 62-107). The average TTR for patients with two or more gaps per year was 10 percentage points lower than for patients without gaps (P < .001). Patient-level predictors of gaps included nonwhite race, area poverty, greater distance from care, dementia, and major depression. Site-level gaps per patient-year varied from 0.19 to 1.78; each one-unit increase was associated with a 9.2 percentage point decrease in site-level TTR (P < .001). Site-level gap rates varied widely within an integrated care system. Sites with more gaps per patient-year had worse anticoagulation control. Strategies to address and reduce gaps in monitoring may improve anticoagulation control.

  1. Complete normal ordering 1: Foundations

    Directory of Open Access Journals (Sweden)

    John Ellis

    2016-08-01

    Full Text Available We introduce a new prescription for quantising scalar field theories (in generic spacetime dimension and background perturbatively around a true minimum of the full quantum effective action, which is to ‘complete normal order’ the bare action of interest. When the true vacuum of the theory is located at zero field value, the key property of this prescription is the automatic cancellation, to any finite order in perturbation theory, of all tadpole and, more generally, all ‘cephalopod’ Feynman diagrams. The latter are connected diagrams that can be disconnected into two pieces by cutting one internal vertex, with either one or both pieces free from external lines. In addition, this procedure of ‘complete normal ordering’ (which is an extension of the standard field theory definition of normal ordering reduces by a substantial factor the number of Feynman diagrams to be calculated at any given loop order. We illustrate explicitly the complete normal ordering procedure and the cancellation of cephalopod diagrams in scalar field theories with non-derivative interactions, and by using a point splitting ‘trick’ we extend this result to theories with derivative interactions, such as those appearing as non-linear σ-models in the world-sheet formulation of string theory. We focus here on theories with trivial vacua, generalising the discussion to non-trivial vacua in a follow-up paper.

  2. [International development cooperation from the D. Orem self-care theory].

    Science.gov (United States)

    Velo Higueras, María; Fajardo Galván, Darío; Cruces González, Marta; Sánchez Merino, Begoña; Santos Muñiz, Ana

    2013-05-01

    This article aim is to analyze the performance of Spanish cooperation from the perspective of Orem self-care theory, from the next hypothesis: the Spanish international cooperation programs works as total compensation systems. cross sectional and descriptive study in which qualitative analysis was performed 3 African countries: Mozambique, Angola and Namibia. The variables were management, focused area and resources used. All countries have a shared management of the cooperation. Mozambique has developed training activities (72%), management support (38%) and direct health care (27%), focused on the area of the fight against infection and tropical diseases. In Angola, the activities are based in training (37%), management support (37%) and health care (75%) in the area of basic health services (25%), fighting against tropical diseases (50%) and improving maternal and child health (25%). Namibia focuses on the health care area (100%) through direct assistance activities and management support. Health cooperation programs developed by the Spanish state have probed to work as partial compensation system.

  3. High-Value Consults: A Curriculum to Promote Point-of-Care, Evidence-Based Recommendations.

    Science.gov (United States)

    Nandiwada, Deepa Rani; Kohli, Amar; McNamara, Megan; Smith, Kenneth J; Zimmer, Shanta; McNeil, Melissa; Spagnoletti, Carla; Rubio, Doris; Berlacher, Kathryn

    2017-10-01

    In an era when value-based care is paramount, teaching trainees to explicitly communicate the evidence behind recommendations fosters high-value care (HVC) in the consultation process. To implement an HVC consult curriculum highlighting the need for clear consult questions, evidence-based recommendations to improve consult teaching, clinical decision-making, and the educational value of consults. A pilot curriculum was implemented for residents on cardiology consult electives utilizing faculty and fellows as evidence-based medicine (EBM) coaches. The curriculum included an online module, an EBM teaching point template, EBM presentations on rounds, and "coach" feedback on notes. A total of 15 residents and 4 fellows on cardiology consults participated, and 87% (13 of 15) of residents on consults felt the curriculum was educationally valuable. A total of 80% (72 of 90) of residents on general medicine rotations responded to the survey, and 25 of 72 residents (35%) had a consult with the EBM template. General medicine teams felt the EBM teaching points affected clinical decision-making (48%, 12 of 25) and favored dissemination of the curriculum (90%, 72 of 80). Checklist-guided chart review showed a 22% improvement in evidence-based summaries behind recommendations (7 of 36 precurriculum to 70 of 146 charts postcurriculum, P  = .015). The HVC consult curriculum during a cardiology elective was perceived by residents to influence clinical decision-making and evidence-based recommendations, and was found to be educationally valuable on both parties in the consult process.

  4. Disparities in psychosocial cancer care: a report from the International Federation of Psycho-oncology Societies.

    Science.gov (United States)

    Grassi, Luigi; Fujisawa, Daisuke; Odyio, Philip; Asuzu, Chioma; Ashley, Laura; Bultz, Barry; Travado, Luzia; Fielding, Richard

    2016-10-01

    The aim of the study was to understand the characteristics of the International Federation of Psycho-oncology Societies (FPOS) and possible disparities in providing psychosocial care in countries where psycho-oncology societies exist. A survey was conducted among 29 leaders of 28 countries represented within the FPOS by using a questionnaire covering (i) characteristics of the society; (ii) characteristics of the national health care system; (iii) level of implementation of psycho-oncology; and (iv) main problems of psycho-oncology in the country. Twenty-six (90%) FPOS returned the questionnaires. One-third reported to have links with and support from their government, while almost all had links with other scientific societies. The FPOS varied in their composition of members' professions. Psychosocial care provision was covered by state-funded health services in a minority of countries. Disparities between countries arose from different causes and were problematic in some parts of the world (eg, Africa and SE Asia). Elsewhere (eg, Southern Europe and Eastern Europe), austerity policies were reportedly responsible for resource shortages with negative consequences on psychosocial cancer care. Half of FPOS rated themselves to be integrated into mainstream provision of care, although lack of funding was the most common complain. The development and implementation of psycho-oncology is fragmented and undeveloped, particularly in some parts of the world. More effort is needed at national level by strong coalitions with oncology societies, better national research initiatives, cancer plans, and patient advocacy, as well as by stronger partnership with international organizations (eg, World Health Organization and Union for International Cancer Control). Copyright © 2016 John Wiley & Sons, Ltd.

  5. Seroprevalence of equine granulocytic anaplasmosis and lyme borreliosis in Canada as determined by a point-of-care enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Schvartz, Gili; Epp, Tasha; Burgess, Hilary J; Chilton, Neil B; Pearl, David L; Lohmann, Katharina L

    2015-06-01

    Equine granulocytic anaplasmosis (EGA) and Lyme borreliosis (LB) are an emerging concern in Canada. We estimated the seroprevalence of EGA and equine LB by testing 376 convenience serum samples from 3 provinces using a point-of-care SNAP(®) 4Dx(®) ELISA (IDEXX Laboratories, Westbrook, Maine, USA), and investigated the agreement between the point-of-care ELISA and laboratory-based serologic tests. The estimated seroprevalence for EGA was 0.53% overall (0.49% in Saskatchewan, 0.71% in Manitoba), while the estimated seroprevalence for LB was 1.6% overall (0.49% in Saskatchewan, 2.86% in Manitoba). There was limited agreement between the point-of-care ELISA and an indirect fluorescent antibody test for EGA (kappa 0.1, PABAK 0.47) and an ELISA/Western blot combination for LB (kappa 0.23, PABAK 0.71). While the SNAP(®) 4Dx(®) ELISA yielded expected seroprevalence estimates, further evaluation of serologic tests for the purposes of disease exposure recognition may be needed.

  6. The international right to health: state obligations and private actors in the health care system.

    Science.gov (United States)

    O'Brien, Paula

    2013-09-01

    Most health systems have historically used a mix of public and private actors for financing and delivering care. But the last 30 years have seen many rich and middle-income countries moving to privatise parts of their health care systems. This phenomenon has generated concerns, especially about equitable access to health care. This article examines what the international right to the highest attainable standard of health in Art 12 of the International Covenant on Economic, Social and Cultural Rights says about the obligations of states which use private actors in health care. The article involves a close study of the primary documents of the key institutions responsible for interpreting and promoting Art 12. From this study, the article concludes that in mixed public-private health care systems, states not only retain primary responsibility for fulfilling the right to health but are subject to a range of additional specific responsibilities.

  7. Clinical accuracy of point-of-care urine culture in general practice

    DEFF Research Database (Denmark)

    Holm, Anne; Cordoba, Gloria; Sørensen, Tina Møller

    2017-01-01

    OBJECTIVE: To assess the clinical accuracy (sensitivity (SEN), specificity (SPE), positive predictive value and negative predictive value) of two point-of-care (POC) urine culture tests for the identification of urinary tract infection (UTI) in general practice. DESIGN: Prospective diagnostic...... uncomplicated, symptomatic UTI. MAIN OUTCOME MEASURES: (1) Overall accuracy of POC urine culture in general practice. (2) Individual accuracy of each of the two POC tests in this study. (3) Accuracy of POC urine culture in general practice with enterococci excluded, since enterococci are known to multiply...... general practices recruited 341 patients with suspected uncomplicated UTI. The overall agreement between index test and reference was 0.76 (CI: 0.71-0.80), SEN 0.88 (CI: 0.83-0.92) and SPE 0.55 (CI: 0.46-0.64). The two POC tests produced similar results individually. Overall agreement with enterococci...

  8. Avaliação da qualidade da assistência ao parto normal Evaluation of the quality of care for normal delivery

    Directory of Open Access Journals (Sweden)

    Margareth Rocha Peixoto Giglio

    2011-10-01

    Full Text Available OBJETIVO: Avaliar a qualidade da assistência hospitalar ao parto normal em Goiânia. MÉTODOS: Foi estudada uma amostra de 404 mulheres que tiveram partos normais em 13 hospitais de Goiânia, durante o período de abril a dezembro de 2007. Os dados foram obtidos de entrevistas com as puérperas e revisão dos prontuários médicos. A qualidade de assistência aos partos foi avaliada por meio do cálculo do índice Bologna e da comparação dos procedimentos utilizados com normas e procedimentos recomendados. RESULTADOS: O índice Bologna apresentou valor médio de 1,04 (IC95%=0,9-1,1. A proporção de cesarianas eletivas foi 30%, a de cesarianas de urgência foi 10% e os partos induzidos representaram 1,6%. A porcentagem de partos assistidos por profissional de saúde foi de 100%, mas o pediatra esteve presente na sala de parto em apenas 30% dos casos. Durante o trabalho de parto, metade das parturientes não teve avaliação da dinâmica uterina e 29,1% não tiveram avaliação dos batimentos cardiofetais, com o partograma sendo utilizado em somente 28,5% dos casos. Por outro lado, a utilização de ocitocina foi de 45,8%. CONCLUSÕES: Os resultados indicam má qualidade da assistência ao parto normal em Goiânia, com baixo valor do índice Bologna, altas proporções de cesarianas eletivas e de urgência, frequência não-adequada de intervenções benéficas e alta ocorrência de algumas intervenções consideradas prejudiciais na assistência ao parto.PURPOSE: To evaluate the quality of health care assistance during childbirth in the hospitals of Goiânia, in Brazil. METHODS: Thirteen hospitals were appraised from April to December 2007, and a random sample of 404 normal births was studied. Data were obtained from interviews with mothers after delivery and by consulting their medical records. The quality of assistance at birth was evaluated by using the Bologna score and by comparing the procedures used in those hospitals to standard

  9. Point-of-Care Diagnostic Device for Traumatic Pneumothorax: Low Sensitivity of the Unblinded PneumoScan™

    Directory of Open Access Journals (Sweden)

    M. Rehfeldt

    2018-01-01

    Full Text Available Background. Traumatic Pneumothorax (PTX is a potentially life-threatening injury. It requires a fast and accurate diagnosis and treatment, but diagnostic tools are limited. A new point-of-care device (PneumoScan based on micropower impulse radar (MIR promises to diagnose a PTX within seconds. In this study, we compare standard diagnostics with PneumoScan during shock-trauma-room management. Patients and Methods. Patients with blunt or penetrating chest trauma were consecutively included in the study. All patients were examined including clinical examination with auscultation (CE and supine chest radiography (CXR. In addition, PneumoScan-readings and thoracic ultrasound scan (US were performed. Computed tomography (CT served as gold standard. Results. CT scan revealed PTX in 11 patients. PneumoScan detected two PTX correctly but missed nine. 15 false-positive results were found by PneumoScan, leading to a sensitivity of 20% and specificity of 80%. Six PTX were detected through CE (sensitivity: 54,5%. CXR detected four (sensitivity: 27,3% and thoracic US two PTX correctly (sensitivity: 25%. Conclusion. The unblinded PneumoScan prototype did not confirm the promising results of previous studies. The examined standard diagnostics and thoracic US showed rather weak sensitivity as well. Until now, there is no appropriate point-of-care tool to rule out PTX.

  10. Pediatric Critical Care Nursing Research Priorities-Initiating International Dialogue.

    Science.gov (United States)

    Tume, Lyvonne N; Coetzee, Minette; Dryden-Palmer, Karen; Hickey, Patricia A; Kinney, Sharon; Latour, Jos M; Pedreira, Mavilde L G; Sefton, Gerri R; Sorce, Lauren; Curley, Martha A Q

    2015-07-01

    To identify and prioritize research questions of concern to the practice of pediatric critical care nursing practice. One-day consensus conference. By using a conceptual framework by Benner et al describing domains of practice in critical care nursing, nine international nurse researchers presented state-of-the-art lectures. Each identified knowledge gaps in their assigned practice domain and then poised three research questions to fill that gap. Then, meeting participants prioritized the proposed research questions using an interactive multivoting process. Seventh World Congress on Pediatric Intensive and Critical Care in Istanbul, Turkey. Pediatric critical care nurses and nurse scientists attending the open consensus meeting. Systematic review, gap analysis, and interactive multivoting. The participants prioritized 27 nursing research questions in nine content domains. The top four research questions were 1) identifying nursing interventions that directly impact the child and family's experience during the withdrawal of life support, 2) evaluating the long-term psychosocial impact of a child's critical illness on family outcomes, 3) articulating core nursing competencies that prevent unstable situations from deteriorating into crises, and 4) describing the level of nursing education and experience in pediatric critical care that has a protective effect on the mortality and morbidity of critically ill children. The consensus meeting was effective in organizing pediatric critical care nursing knowledge, identifying knowledge gaps and in prioritizing nursing research initiatives that could be used to advance nursing science across world regions.

  11. Clinical Evaluation of 2 Point-of-Care Lateral Flow Tests for the Diagnosis of Syphilis.

    Science.gov (United States)

    Nakku-Joloba, Edith; Kiragga, Agnes; Mbazira, Joshua Kimeze; Kambugu, Fred; Jett-Goheen, Mary; Ratanshi, Rosalind Parkes; Gaydos, Charlotte; Manabe, Yukari C

    2016-10-01

    A diagnostic performance study comparing the only Food and Drug Administration-approved, point-of-care (POC) treponemal test (Syphilis Health Check) and the World Health Organization pre-qualified SD Bioline POC treponemal test against a treponemal hemagglutination test (TPHA) and a sequential algorithm of nontreponemal rapid plasma reagin and TPHA found both POC tests had >85% sensitivity compared with the TPHA and >85% sensitivity and >95% specificity compared with the rapid plasma reagin and TPHA standards.

  12. Data from the analytical performance of the Abaxis Piccolo Xpress point of care analyzer in whole blood, serum, and plasma

    Directory of Open Access Journals (Sweden)

    Kazunori Murata

    2018-02-01

    Full Text Available The objective of this study was to examine the analytical performance of 14 comprehensive metabolic panel analytes on the Abaxis Piccolo Xpress® Point of Care analyzer in serum, plasma, and whole blood. A method comparison was performed on all three specimen types intended for use on the Piccolo Xpress®: serum, heparinized plasma, and whole blood. This data is also presented in Murata et al. (2015 [1]. This article includes the actual Bland-Altman bias plots of the difference in results obtained for analytes in the comprehensive metabolic panel from the Abaxis Piccolo Xpress and the comparison instrument, the Ortho Vitros. Keywords: Clinical chemistry, Point-of care testing

  13. Effects of knowledge and internal locus of control in groups of health care workers judging likelihood of pathogen transfer.

    Science.gov (United States)

    McLaughlin, Anne Collins; Walsh, Fran; Bryant, Michelle

    2013-08-01

    A study was conducted to measure the effects of attitudes and beliefs on the risk judgments of health care workers. Lack of hand hygiene compliance is a worldwide issue in health care, contributing to infections, fatalities, and increased health care costs. Human factors methods are a promising solution to the problem of compliance, although thus far, the concentration has been on process and engineering methods, such as the design of no-touch sinks. Factors internal to the health care worker, such as their attitudes and beliefs about hand hygiene, have received less attention. For this study, three groups of health care workers completed measures of attitudes, control beliefs, and hand hygiene knowledge. They then provided risk judgments of touching various surfaces via a factorial survey. Attitudes, knowledge, control beliefs, and surface type all predicted the risk judgments of the sample of health care workers, with differences between professional groups. Health care workers perceive less risk when touching surfaces,which may explain historically low rates of hand hygiene compliance after surface contact. Although more research is needed to directly connect risk judgments to failures of hand hygiene, the current results can inform interventions targeting the internal attitudes and beliefs of health care workers.

  14. On the meaning of sink capture efficiency and sink strength for point defects

    International Nuclear Information System (INIS)

    Mansur, L.K.; Wolfer, W.G.

    1982-01-01

    The concepts of sink capture efficiency and sink strength for point defects are central to the theory of point defect reactions in materials undergoing irradiation. Two fundamentally different definitions of the capture efficiency are in current use. The essential difference can be stated simply. The conventional meaning denotes a measure of the loss rate of point defects to sinks per unit mean point defect concentration. A second definition of capture efficiency, introduced recently, gives a measure of the point defect loss rate without normalization to the mean point defect concentration. The relationship between the two capture efficiencies is here derived. By stating the relationship we hope to eliminate confusion caused by comparisons of the two types of capture efficiencies at face value and to provide a method of obtaining one from the other. Internally consistent usage of either of the capture efficiencies leads to the same results for the calculation of measuable quantities, as is required physically. (orig.)

  15. Value of point-of-care ketones in assessing dehydration and acidosis in children with gastroenteritis.

    Science.gov (United States)

    Levy, Jason A; Waltzman, Mark; Monuteaux, Michael C; Bachur, Richard G

    2013-11-01

    Children with gastroenteritis often develop dehydration with metabolic acidosis. Serum ketones are frequently elevated in this population. The goal was to determine the relationship between initial serum ketone concentration and both the degree of dehydration and the magnitude of acidosis. This was a secondary analysis of a prospective trial of crystalloid administration for rapid rehydration. Children 6 months to 6 years of age with gastroenteritis and dehydration were enrolled. A point-of-care serum ketone (beta-hydroxybutyrate) concentration was obtained at the time of study enrollment. The relationship between initial serum ketone concentration and a prospectively assigned and previously validated clinical dehydration score, and serum bicarbonate concentration, was analyzed. A total of 188 patients were enrolled. The median serum ketone concentration was elevated at 3.1 mmol/L (interquartile range [IQR] = 1.2 to 4.6 mmol/L), and the median dehydration score was consistent with moderate dehydration. A significant positive relationship was found between serum ketone concentration and the clinical dehydration score (Spearman's rho = 0.22, p = 0.003). Patients with moderate dehydration had a higher median serum ketone concentration than those with mild dehydration (3.6 mmol/L vs. 1.4 mmol/L, p = 0.007). Additionally, the serum ketone concentration was inversely correlated with serum bicarbonate concentration (ρ = -0.26, p Children with gastroenteritis and dehydration have elevated serum ketone concentrations that correlate with both degree of dehydration and magnitude of metabolic acidosis. Point-of-care serum ketone measurement may be a useful tool to inform management decisions at the point of triage or in the initial evaluation of children with gastroenteritis and dehydration. © 2013 by the Society for Academic Emergency Medicine.

  16. International standards for tuberculosis care: Relevance and implications for laboratory professionals

    Directory of Open Access Journals (Sweden)

    Pai M

    2007-01-01

    Full Text Available On World Tuberculosis (TB Day 2006, the International Standards for Tuberculosis Care (ISTC was officially released and widely endorsed by several agencies and organizations. The ISTC release was the culmination of a year long global effort to develop and set internationally acceptable, evidence-based standards for tuberculosis care. The ISTC describes a widely endorsed level of care that all practitioners, public and private, should seek to achieve in managing individuals who have or are suspected of having, TB and is intended to facilitate the effective engagement of all healthcare providers in delivering high quality care for patients of all ages, including those with smear-positive, smear-negative and extra-pulmonary TB, TB caused by drug-resistant Mycobacterium tuberculosis and TB/HIV coinfection. In this article, we present the ISTC, with a special focus on the diagnostic standards and describe their implications and relevance for laboratory professionals in India and worldwide. Laboratory professionals play a critical role in ensuring that all the standards are actually met by providing high quality laboratory services for smear microscopy, culture and drug susceptibility testing and other services such as testing for HIV infection. In fact, if the ISTC is widely followed, it can be expected that there will be a greater need and demand for quality assured laboratory services and this will have obvious implications for all laboratories in terms of work load, requirement for resources and trained personnel and organization of quality assurance systems.

  17. International practice settings, interventions and outcomes of nurse practitioners in geriatric care: A scoping review.

    Science.gov (United States)

    Chavez, Krista S; Dwyer, Andrew A; Ramelet, Anne-Sylvie

    2018-02-01

    To identify and summarize the common clinical settings, interventions, and outcomes of nurse practitioner care specific to older people. Scoping review of the international published and grey literature. A structured literature search was conducted of CINAHL, EMBASE, MEDLINE, Google Scholar, and Cochrane Collaboration and Joanna Briggs Institute databases. Following the Arksey and O'Malley framework, randomized controlled and quasi-experimental studies of Masters-prepared nurse practitioners providing care for patients over 65 years were included. Studies were reviewed independently by two investigators. Data were extracted, collated by setting, summarized in tables and synthesized for analysis. In total, 56 primary research studies from four countries and 23 systematic reviews were identified. Primary studies were conducted in primary care (n=13), home care (n=14), long-term care (n=10), acute/hospital care (n=9), and transitional care (n=10). Nurse practitioner interventions included substitutive as well as a supplementation NP role elements to meet specific unmet patient care needs. Studies examined six main outcome measures: service utilization (n=41), cost (n=24), length of stay (n=14), health indices (n=44), satisfaction (n=14) and quality of life (n=7). Cumulatively, nurse practitioners demonstrated enhanced results in 83/144 (58%) of outcomes compared to physician-only or usual care. The most commonly measured financial-related outcome was service utilization (n=41) and benefits were frequently reported in home care (8/9, 89%) and long-term care (7/10, 70%) settings. Among patient and care-related outcomes health indices were most frequently measured (n=44). Primary care most frequently reported improved health indices (11/13, 85%). Transitional care reported improved outcomes across all measures, except for service utilization. This review demonstrates improved or non-inferiority results of nurse practitioner care in older people across settings. More well

  18. Dyspnea in the ambulance - etiology, mortality, and point-of-care diagnostics

    DEFF Research Database (Denmark)

    Bøtker, Morten Thingemann

    2016-01-01

    dyspnea in the ambulance requires identification of high-risk groups and early correct treatment. Bringing forward simplified versions of advanced diagnostic modalities known from the hospital as point-of-care diagnostics already in the ambulance may aid the discrimination of underlying conditions causing......, we included all patients dialing the emergency number (1-1-2) due to a medical emergency in three of five Danish regions. For identification of highrisk patients and evaluation of electrocardiogram-based triage, we compared short-term mortality between patients included in the first study based...... that are highly prioritized in emergency medical services – including chest pain and trauma. Whether this increased mortality can be ascribed to an older age and comorbidity among patients suffering dyspnea, or if modifiable risk factors are also present, is unsettled. Improving outcome for patients suffering...

  19. Henry Hub and national balancing point prices: what will be the international gas price reference?

    International Nuclear Information System (INIS)

    Mazighi, A.E.H.

    2005-01-01

    One of the lessons in the history of international trade in commodities is the emergence - sooner or later - of an international price reference, most commonly known as an international marker price. In the area of oil, West Texas Intermediate (WTI) plays the role of a marker for sour crudes traded in the Atlantic basin. Brent oil fulfils this function for sweet crudes traded in Europe. Another important aspect in the area of global commodities is that the emergence of a marker price is not always necessarily related to the relative share of production of exports of the commodity, but primarily to the existence of an organized market for this commodity. Today, while international gas trade is intensifying, we still lack an international price reference for this commodity. This is due to the fact that the international trade of natural gas is still highly regionalized. It is also due to the fact that most gas markets are still regulated. Nevertheless, deregulation efforts have been implemented in both developed (the United States, the United Kingdom, continental Europe, Korea) and developing countries (Brazil, Chile) and have led to new market structures based on more competition in all segments of the gas chain, except transportation. In the meantime, price structures based on supply and demand principles are supposed to have emerged in the US and UK markets in the 1990s as a result of the implementation of deregulation measures. Today, the US gas market, which represents more than 660 billion cubic metres per year of consumption and the UK gas market, which is close to 100 bcm annually, are considered mature enough to make the principles of supply and demand operate inside these markets. In fact, the Henry Hub (HH) price, which is determined at a physical location in Louisiana, US, and the national balancing point (NBP) price, which is determined somewhere inside the national transmission system (NTS), without any precise location, are considered as potential

  20. Point-of-care testing for chlamydia and gonorrhoea: implications for clinical practice.

    Directory of Open Access Journals (Sweden)

    Lisa Natoli

    Full Text Available Point-of-care (POC testing for chlamydia (CT and gonorrhoea (NG offers a new approach to the diagnosis and management of these sexually transmitted infections (STIs in remote Australian communities and other similar settings. Diagnosis of STIs in remote communities is typically symptom driven, and for those who are asymptomatic, treatment is generally delayed until specimens can be transported to the reference laboratory, results returned and the patient recalled. The objective of this study was to explore the clinical implications of using CT/NG POC tests in routine clinical care in remote settings.In-depth qualitative interviews were conducted with a purposively selected group of 18 key informants with a range of sexual health and laboratory expertise.Participants highlighted the potential impact POC testing would have on different stages of the current STI management pathway in remote Aboriginal communities and how the pathway would change. They identified implications for offering a POC test, specimen collection, conducting the POC test, syndromic management of STIs, pelvic inflammatory disease diagnosis and management, interpretation and delivery of POC results, provision of treatment, contact tracing, management of client flow and wait time, and re-testing at 3 months after infection.The introduction of POC testing to improve STI service delivery requires careful consideration of both its advantages and limitations. The findings of this study will inform protocols for the implementation of CT/NG POC testing, and also STI testing and management guidelines.

  1. Point-of-Care Testing for Chlamydia and Gonorrhoea: Implications for Clinical Practice

    Science.gov (United States)

    Natoli, Lisa; Maher, Lisa; Shephard, Mark; Hengel, Belinda; Tangey, Annie; Badman, Steven G.; Ward, James; Guy, Rebecca J.

    2014-01-01

    Objectives Point-of-care (POC) testing for chlamydia (CT) and gonorrhoea (NG) offers a new approach to the diagnosis and management of these sexually transmitted infections (STIs) in remote Australian communities and other similar settings. Diagnosis of STIs in remote communities is typically symptom driven, and for those who are asymptomatic, treatment is generally delayed until specimens can be transported to the reference laboratory, results returned and the patient recalled. The objective of this study was to explore the clinical implications of using CT/NG POC tests in routine clinical care in remote settings. Methods In-depth qualitative interviews were conducted with a purposively selected group of 18 key informants with a range of sexual health and laboratory expertise. Results Participants highlighted the potential impact POC testing would have on different stages of the current STI management pathway in remote Aboriginal communities and how the pathway would change. They identified implications for offering a POC test, specimen collection, conducting the POC test, syndromic management of STIs, pelvic inflammatory disease diagnosis and management, interpretation and delivery of POC results, provision of treatment, contact tracing, management of client flow and wait time, and re-testing at 3 months after infection. Conclusions The introduction of POC testing to improve STI service delivery requires careful consideration of both its advantages and limitations. The findings of this study will inform protocols for the implementation of CT/NG POC testing, and also STI testing and management guidelines. PMID:24956111

  2. [Day hospital in internal medicine: A chance for ambulatory care].

    Science.gov (United States)

    Grasland, A; Mortier, E

    2018-04-16

    Internal medicine is an in-hospital speciality. Along with its expertise in rare diseases, it shares with general medicine the global care of patients but its place in the ambulatory shift has yet to be defined. The objective of our work was to evaluate the benefits of an internal medicine day-hospital devoted to general medicine. Named "Centre Vi'TAL" to underline the link between the city and the hospital, this novel activity was implemented in order to respond quickly to general practitioners having difficulties to synthesize their complex patients or facing diagnostic or therapeutic problems. Using preferentially email for communication, the general practitioners can contact an internist who is committed to respond on the same day and take over the patient within 7 days if day-hospital is appropriate for his condition. The other patients are directed either to the emergency department, consultation or full hospitalization. In 14 months, the center has received 213 (144 women, 69 men) patients, mean age 53.6, addressed by 88 general practitioners for 282 day-hospital sessions. Requests included problem diagnoses (n=105), synthesis reviews for complex patients (n=65), and treatment (n=43). In the ambulatory shift advocated by the authorities, this experience shows that internal medicine should engage in the recognition of day-hospital as a place for diagnosis and synthesis reviews connected with the city while leaving the general practitioners coordinator of their patient care. This activity of synthesis in day-hospital is useful for the patients and efficient for our healthcare system. Copyright © 2018 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  3. Nanobody-Based Apolipoprotein E Immunosensor for Point-of-Care Testing.

    Science.gov (United States)

    Ren, Xiang; Yan, Junrong; Wu, Dan; Wei, Qin; Wan, Yakun

    2017-09-22

    Alzheimer's disease (AD) biomarkers can reflect the neurochemical indicators used to estimate the risk in clinical nephrology. Apolipoprotein E (ApoE) is an early biomarker for AD in clinical diagnosis. In this research, through bactrian camel immunization, lymphocyte isolation, RNA extraction, and library construction, ApoE-specific Nbs with high affinity were successfully separated from an immune phage display nanobody library. Herein, a colorimetric immunosensor was developed for the point-of-care testing of ApoE by layer-by-layer nanoassembly techniques and novel nanobodies (Nbs). Using highly oriented Nbs as the capture and detection antibodies, an on-site immunosensor was developed by detecting the mean gray value of fade color due to the glutaraldehyde@3-aminopropyltrimethoxysilane oxidation by H 2 O 2 . The detection limit of AopE is 0.42 pg/mL, and the clinical analysis achieves a good performance. The novel easily operated immunosensor may have potential application in the clinical diagnosis and real-time monitoring for AD.

  4. The laboratory information float, time-based competition, and point-of-care testing.

    Science.gov (United States)

    Friedman, B A

    1994-01-01

    A new term, the laboratory information float, should be substituted for turnaround-time when evaluating the performance of the clinical laboratory because it includes the time necessary to make test results both available (ready to use) and accessible (easy to use) to clinicians ordering tests. The laboratory information float can be greatly reduced simply by telescoping the analytic phase of laboratory testing into the preanalytic phase. Significant costs are incurred by such a change, some of which can be reduced by developing a mobile clinical laboratory (sometimes referred to as a "lab-on-a-slab" or "rolling thunder") to transport the analytic devices directly to patient care units. The mobile clinical laboratory should be equipped with an integrated personal computer that can communicate continuously with the host laboratory information system and achieve some semblance of continuous flow processing despite test performance in point-of-care venues. Equipping clinicians with palmtop computers will allow the mobile clinician to access test results and order tests on the run. Such devices can be easily configured to operate in a passive mode, accessing relevant information automatically instead of forcing clinicians to query the laboratory information system periodically for the test results necessary to render care to their patients. The laboratory information float of the year 2,000 will surely be measured in minutes through the judicious deployment of relevant technology such as mobile clinical laboratories and palmtop computers.

  5. Immediate Emergency Department Diagnosis of Pyloric Stenosis with Point-of-care Ultrasound

    Directory of Open Access Journals (Sweden)

    Nicole Dorinzi

    2017-11-01

    Full Text Available A 15-day-old male who was born at term presented with non-bilious projectile vomiting. He was nontoxic and his abdomen was benign without masses. Point-of-care ultrasound (POCUS showed hypertrophic pyloric stenosis (HPS. Typical findings include target sign; pyloric muscle thickness greater than three millimeters (mm; channel length greater than 15–18 mm; and lack of gastric emptying. The patient was admitted; consultative ultrasound (US was negative, but repeated 48 hours later for persistent vomiting. This second US was interpreted as HPS, which was confirmed surgically. Pyloromyotomy was successful. Few reports describe POCUS by general emergency physicians to diagnose HPS. Here, we emphasize the value in repeat US for patients with persistent symptoms.

  6. A System-on-Chip Solution for Point-of-Care Ultrasound Imaging Systems: Architecture and ASIC Implementation.

    Science.gov (United States)

    Kang, Jeeun; Yoon, Changhan; Lee, Jaejin; Kye, Sang-Bum; Lee, Yongbae; Chang, Jin Ho; Kim, Gi-Duck; Yoo, Yangmo; Song, Tai-kyong

    2016-04-01

    In this paper, we present a novel system-on-chip (SOC) solution for a portable ultrasound imaging system (PUS) for point-of-care applications. The PUS-SOC includes all of the signal processing modules (i.e., the transmit and dynamic receive beamformer modules, mid- and back-end processors, and color Doppler processors) as well as an efficient architecture for hardware-based imaging methods (e.g., dynamic delay calculation, multi-beamforming, and coded excitation and compression). The PUS-SOC was fabricated using a UMC 130-nm NAND process and has 16.8 GFLOPS of computing power with a total equivalent gate count of 12.1 million, which is comparable to a Pentium-4 CPU. The size and power consumption of the PUS-SOC are 27×27 mm(2) and 1.2 W, respectively. Based on the PUS-SOC, a prototype hand-held US imaging system was implemented. Phantom experiments demonstrated that the PUS-SOC can provide appropriate image quality for point-of-care applications with a compact PDA size ( 200×120×45 mm(3)) and 3 hours of battery life.

  7. A paper based graphene-nanocauliflower hybrid composite for point of care biosensing

    Science.gov (United States)

    Burrs, S. L.; Sidhu, R.; Bhargava, M.; Kiernan-Lewis, J.; Schwalb, N.; Rong, Y.; Gomes, C.; Claussen, J.; Vanegas, D. C.; McLamore, E. S.

    2016-05-01

    Graphene paper has diverse applications in printed circuit board electronics, bioassays, 3D cell culture, and biosensing. Although development of nanometal-graphene hybrid composites is commonplace in the sensing literature, to date there are only a few examples of nanometal-decorated graphene paper for use in biosensing. In this manuscript, we demonstrate the synthesis and application of Pt nano cauliflower-functionalized graphene paper for use in electrochemical biosensing of small molecules (glucose, acetone, methanol) or detection of pathogenic bacteria (Escherichia coli O157:H7). Raman spectroscopy, scanning electron microscopy and energy dispersive spectroscopy were used to show that graphene oxide deposited on nanocellulose crystals was partially reduced by both thermal and chemical treatment. Fractal platinum nanostructures were formed on the reduced graphene oxide paper, producing a conductive paper with an extremely high electroactive surface area, confirmed by cyclic voltammetry and electrochemical impedance spectroscopy. To show the broad applicability of the material, the platinum surface was functionalized with three different biomaterials: 1) glucose oxidase (via chitosan encapsulation); 2) a DNA aptamer (via covalent linking), or 3) a chemosensory protein (via his linking). We demonstrate the application of this device for point of care biosensing. The detection limit for both glucose (0.08 +/- 0.02 μM) and E. coli O157:H7 (1.3 +/- 0.1 CFU mL-1) were competitive with, or superior to, previously reported devices in the biosensing literature. The response time (6 sec for glucose and 10 min for E. coli) were also similar to silicon biochip and commercial electrode sensors. The results demonstrate that the nanocellulose-graphene-nanoplatinum material is an excellent paper-based platform for development of electrochemical biosensors targeting small molecules or whole cells for use in point of care biosensing.

  8. Guidelines for Improving Entry Into and Retention in Care and Antiretroviral Adherence for Persons With HIV: Evidence-Based Recommendations From an International Association of Physicians in AIDS Care Panel

    Science.gov (United States)

    Thompson, Melanie A.; Mugavero, Michael J.; Amico, K. Rivet; Cargill, Victoria A.; Chang, Larry W.; Gross, Robert; Orrell, Catherine; Altice, Frederick L.; Bangsberg, David R.; Bartlett, John G.; Beckwith, Curt G.; Dowshen, Nadia; Gordon, Christopher M.; Horn, Tim; Kumar, Princy; Scott, James D.; Stirratt, Michael J.; Remien, Robert H.; Simoni, Jane M.; Nachega, Jean B.

    2014-01-01

    Description After HIV diagnosis, timely entry into HIV medical care and retention in that care are essential to the provision of effective antiretroviral therapy (ART). ART adherence is among the key determinants of successful HIV treatment outcome and is essential to minimize the emergence of drug resistance. The International Association of Physicians in AIDS Care convened a panel to develop evidence-based recommendations to optimize entry into and retention in care and ART adherence for people with HIV. Methods A systematic literature search was conducted to produce an evidence base restricted to randomized, controlled trials and observational studies with comparators that had at least 1 measured biological or behavioral end point. A total of 325 studies met the criteria. Two reviewers independently extracted and coded data from each study using a standardized data extraction form. Panel members drafted recommendations based on the body of evidence for each method or intervention and then graded the overall quality of the body of evidence and the strength for each recommendation. Recommendations Recommendations are provided for monitoring of entry into and retention in care, interventions to improve entry and retention, and monitoring of and interventions to improve ART adherence. Recommendations cover ART strategies, adherence tools, education and counseling, and health system and service delivery interventions. In addition, they cover specific issues pertaining to pregnant women, incarcerated individuals, homeless and marginally housed individuals, and children and adolescents, as well as substance use and mental health disorders. Recommendations for future research in all areas are also provided. PMID:22393036

  9. Implementation of a 4-Year Point-of-Care Ultrasound Curriculum in a Liaison Committee on Medical Education-Accredited US Medical School.

    Science.gov (United States)

    Wilson, Sean P; Mefford, Jason M; Lahham, Shadi; Lotfipour, Shahram; Subeh, Mohammad; Maldonado, Gracie; Spann, Sophie; Fox, John C

    2017-02-01

    The established benefits of point-of-care ultrasound have given rise to multiple new and innovative curriculums to incorporate ultrasound teaching into medical education. This study sought to measure the educational success of a comprehensive and integrated 4-year point-of-care ultrasound curriculum. We integrated a curriculum consisting of traditional didactics combined with asynchronous learning modules and hands-on practice on live models with skilled sonographers into all 4 years of education at a Liaison Committee on Medical Education-accredited US Medical School. Each graduating student was administered an exit examination with 48 questions that corresponded to ultrasound milestones. Ninety-five percent (n = 84) of fourth-year medical students completed the exit examination. The mean score was 79.5% (SD, 10.2%), with mean scores on the ultrasound physics and anatomy subsections being 77.1% (SD, 11.0%) and 85.9% (SD, 21.0%), respectively. A comprehensive 4-year point-of-care ultrasound curriculum integrated into medical school may successfully equip graduating medical students with a fundamental understanding of ultrasound physics, anatomy, and disease recognition. © 2016 by the American Institute of Ultrasound in Medicine.

  10. Finding a solution: Heparinised saline versus normal saline in the maintenance of invasive arterial lines in intensive care.

    Science.gov (United States)

    Everson, Matthew; Webber, Lucy; Penfold, Chris; Shah, Sanjoy; Freshwater-Turner, Dan

    2016-11-01

    We assessed the impact of heparinised saline versus 0.9% normal saline on arterial line patency. Maintaining the patency of arterial lines is essential for obtaining accurate physiological measurements, enabling blood sampling and minimising line replacement. Use of heparinised saline is associated with risks such as thrombocytopenia, haemorrhage and mis-selection. Historical studies draw variable conclusions but suggest that normal saline is at least as effective at maintaining line patency, although recent evidence has questioned this. We conducted a prospective analysis of the use of heparinised saline versus normal saline on unselected patients in the intensive care of our hospital. Data concerning duration of 471 lines insertion and reason for removal was collected. We found a higher risk of blockage for lines flushed with normal saline compared with heparinised saline (RR = 2.15, 95% CI 1.392-3.32, p  ≤ 0.001). Of the 56 lines which blocked initially (19 heparinised saline and 37 normal saline lines), 16 were replaced with new lines; 5 heparinised saline lines and 11 normal saline lines were reinserted; 5 of these lines subsequently blocked again, 3 of which were flushed with normal saline. Our study demonstrates a clinically important reduction in arterial line longevity due to blockages when flushed with normal saline compared to heparinised saline. We have determined that these excess blockages have a significant clinical impact with further lines being inserted after blockage, resulting in increased risks to patients, wasted time and cost of resources. Our findings suggest that the current UK guidance favouring normal saline flushes should be reviewed.

  11. MISTRAL V1.1.1: assessing doses from atmospheric releases in normal and off-normal conditions

    International Nuclear Information System (INIS)

    David Kerouanton; Patrick Devin; Malvina Rennesson

    2006-01-01

    Protecting the environment and the public from radioactive and chemical hazards has always been a top priority for all companies operating in the nuclear domain. In this scope, SGN provides all the services the nuclear industry needs in environmental studies especially in relation to the impact assessment in normal operating conditions and risk assessment in off-normal conditions. In order to quantify dose impact on members of the public due to atmospheric releases, COGEMA and SGN developed MISTRAL V1.1.1 code. Dose impact depends strongly on dispersion of radionuclides in atmosphere. The main parameters involved in dispersion characterization are wind velocity and direction, rain, diffusion conditions, coordinates of the point of observation and stack elevation. MISTRAL code implements DOURY and PASQUILL Gaussian plume models which are widely used in the scientific community. These models, applicable for distances of transfer ranging from 100 m up to 30 km, are used to calculate atmospheric concentration and deposit at different distances from the point of release. MISTRAL allows the use of different dose regulations or dose coefficient databases such as: - ICRP30 and ICPR71 for internal doses (inhalation, ingestion) - Despres/Kocher database or US-EPA Federal Guidance no.12 (ICPR72 for noble gases) for external exposure (from plume or ground). The initial instant of the release can be considered as the origin of time or a date format can be specified (could be useful in a crisis context). While the context is specified, the user define the meteorological conditions of the release. In normal operating mode (routine releases), the user gives the annual meteorological scheme. The data can be recorded in the MISTRAL meteorological database. In off-normal conditions mode, MISTRAL V1.1 allows the use of successive release stages for which the user gives the duration, the meteorological conditions, that is to say stability class, wind speed and direction and rainfall

  12. Microfluidic-integrated biosensors: prospects for point-of-care diagnostics.

    Science.gov (United States)

    Kumar, Suveen; Kumar, Saurabh; Ali, Md Azahar; Anand, Pinki; Agrawal, Ved Varun; John, Renu; Maji, Sagar; Malhotra, Bansi D

    2013-11-01

    There is a growing demand to integrate biosensors with microfluidics to provide miniaturized platforms with many favorable properties, such as reduced sample volume, decreased processing time, low cost analysis and low reagent consumption. These microfluidics-integrated biosensors would also have numerous advantages such as laminar flow, minimal handling of hazardous materials, multiple sample detection in parallel, portability and versatility in design. Microfluidics involves the science and technology of manipulation of fluids at the micro- to nano-liter level. It is predicted that combining biosensors with microfluidic chips will yield enhanced analytical capability, and widen the possibilities for applications in clinical diagnostics. The recent developments in microfluidics have helped researchers working in industries and educational institutes to adopt some of these platforms for point-of-care (POC) diagnostics. This review focuses on the latest advancements in the fields of microfluidic biosensing technologies, and on the challenges and possible solutions for translation of this technology for POC diagnostic applications. We also discuss the fabrication techniques required for developing microfluidic-integrated biosensors, recently reported biomarkers, and the prospects of POC diagnostics in the medical industry. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Toward an Appropriate Point-of-Care Ultrasound Curriculum: A Reflection of the Clinical Practice in South Africa

    Directory of Open Access Journals (Sweden)

    Daniël Jacobus van Hoving

    2016-03-01

    Conclusions: This study indicates a mismatch between the current point-of-care ultrasound curriculum and the clinical burden of disease experienced. Disease burden, disease impact, technical difficulty of ultrasound applications, and logistical barriers need to be incorporated when considering a change in the curriculum to make it more appropriate for the South African setting.

  14. Flexible low-cost cardiovascular risk marker biosensor for point-of-care applications

    KAUST Repository

    Sivashankar, Shilpa

    2015-10-22

    The detection and quantification of protein on a laser written flexible substrate for point-of-care applications are described. A unique way of etching gold on polyethylene terephthalate (PET) substrate is demonstrated by reducing the damage that may be caused on PET sheets otherwise. On the basis of the quantity of the C-reactive protein (CRP) present in the sample, the risk of cardiac disease can be assessed. This hsCRP test is incorporated to detect the presence of CRP on a PET laser patterned biosensor. Concentrations of 1, 2, and 10 mg/l were chosen to assess the risk of cardiac diseases as per the limits set by the American Heart Association.

  15. Successful Integration of Hepatitis C Virus Point-of-Care Tests into the Denver Metro Health Clinic

    Directory of Open Access Journals (Sweden)

    A. Jewett

    2013-01-01

    Full Text Available Background. The Centers for Disease Control and Prevention (CDC recommends testing and linkage to care for persons most likely infected with hepatitis C virus (HCV, including persons with human immunodeficiency virus. We explored facilitators and barriers to integrating HCV point-of-care (POC testing into standard operations at an urban STD clinic. Methods. The OraQuick HCV rapid antibody test was integrated at the Denver Metro Health Clinic (DMHC. All clients with at least one risk factor were offered the POC test. Research staff conducted interviews with clients (three HCV positive and nine HCV negative. Focus groups were conducted with triage staff, providers, and linkage-to-care counselors. Results. Clients were pleased with the ease of use and rapid return of results from the HCV POC test. Integrating the test into this setting required more time but was not overly burdensome. While counseling messages were clear to staff, clients retained little knowledge of hepatitis C infection or factors related to risk. Barriers to integrating the HCV POC test into clinic operations were loss to follow-up and access to care. Conclusion. DMHC successfully integrated HCV POC testing and piloted a HCV linkage-to-care program. Providing testing opportunities at STD clinics could increase identification of persons with HCV infection.

  16. Scenario-Based Assessment of User Needs for Point-of-Care Robots.

    Science.gov (United States)

    Lee, Hyeong Suk; Kim, Jeongeun

    2018-01-01

    This study aimed to derive specific user requirements and barriers in a real medical environment to define the essential elements and functions of two types of point-of-care (POC) robot: a telepresence robot as a tool for teleconsultation, and a bedside robot to provide emotional care for patients. An analysis of user requirements was conducted; user needs were gathered and identified, and detailed, realistic scenarios were created. The prototype robots were demonstrated in physical environments for envisioning and evaluation. In all, three nurses and three clinicians participated as evaluators to observe the demonstrations and evaluate the robot systems. The evaluators were given a brief explanation of each scene and the robots' functionality. Four major functions of the teleconsultation robot were defined and tested in the demonstration. In addition, four major functions of the bedside robot were evaluated. Among the desired functions for a teleconsultation robot, medical information delivery and communication had high priority. For a bedside robot, patient support, patient monitoring, and healthcare provider support were the desired functions. The evaluators reported that the teleconsultation robot can increase support from and access to specialists and resources. They mentioned that the bedside robot can improve the quality of hospital life. Problems identified in the demonstration were those of space conflict, communication errors, and safety issues. Incorporating this technology into healthcare services will enhance communication and teamwork skills across distances and thereby facilitate teamwork. However, repeated tests will be needed to evaluate and ensure improved performance.

  17. Evaluation of point-of-care analyzers' ability to reduce bias in conductivity-based hematocrit measurement during cardiopulmonary bypass

    NARCIS (Netherlands)

    Teerenstra, S.; Steinfelder-Visscher, J.; Gunnewiek, J.K.; Weerwind, P.W.

    2014-01-01

    Most point-of-care testing analyzers use the conductivity method to measure hematocrit (hct). During open-heart surgery, blood-conductivity is influenced by shifts in electrolyte and colloid concentrations caused by infusion media used, and this may lead to considerable bias in the hct measurement.

  18. [State of internal communication in primary care].

    Science.gov (United States)

    Ballvé Moreno, José Luis; Pujol Ribó, Gloria; Romaguera Lliso, Amparo; Bonet Esteve, Anna; Rafecas Ruiz, Montserrat; Zarza Carretero, Elvira

    2008-08-01

    To study internal communication between primary care health professionals Cross-sectional, descriptive. Catalan Health Institute Costa de Ponent Primary Care Area, Spain. All workers in the area (n=3565). Three part questionnaire: a) sociodemographic questions; b) questions scoring from 0 to 10 the current importance and operation of certain aspects; and c) questions on new communication tools. Of those sent a questionnaire, 39% (n=1388) responded, with a mean age of 43.2 years (95% CI, 42.75- 43.65), 28.9% being male. The major differences between importance and current events were said to be "to be informed of projects before they appear in the communication media," "by official routes and not by rumour," and "to be aware of projects of other teams." The least communicated within teams. The doctors considered upward communication to be more important. Doctors are those who appreciate communication within teams better and the professionals of the users services unit (UAU) less so. Doctors are the ones who give more importance to being informed of projects at the time. 55% do not use the intranet, mainly due to lack of time. The second reason is that they find it difficult. Sixty-two per cent read e-mail >2-3 times per week. Eighty-nine per cent want an electronic bulletin. The older workers use new technologies less. Downward, upward, and sideways communication needs to be improved, particularly upwards by doctors, and that of the teams for the UAU professionals. Intranet tools must be provided that make the work easier and training in handling new technologies must be offered.

  19. Corporate strategy and the organizational structure of companies in international business

    Directory of Open Access Journals (Sweden)

    Aleksić Ana

    2004-01-01

    Full Text Available The aim of this paper is to illuminate the importance of corporate strategy and organizational structure as crucial variables for successful international business. We wanted to point out that companies, in order to exploit opportunities in international environment, must develop a high level of consent between the applied strategy and the model of organizational structure. Today all organizations, no matter how big they are, are affected by the international environment and its management must consider very carefully the benefits and costs of alternative strategies and the corresponding models of organizational structure.

  20. Impact of financial incentives on clinical autonomy and internal motivation in primary care: ethnographic study.

    Science.gov (United States)

    McDonald, Ruth; Harrison, Stephen; Checkland, Kath; Campbell, Stephen M; Roland, Martin

    2007-06-30

    To explore the impact of financial incentives for quality of care on practice organisation, clinical autonomy, and internal motivation of doctors and nurses working in primary care. Ethnographic case study. Two English general practices. 12 general practitioners, nine nurses, four healthcare assistants, and four administrative staff. Observation of practices over a five month period after the introduction of financial incentives for quality of care introduced in the 2004 general practitioner contract. After the introduction of the quality and outcomes framework there was an increase in the use of templates to collect data on quality of care. New regimens of surveillance were adopted, with clinicians seen as "chasers" or the "chased," depending on their individual responsibility for delivering quality targets. Attitudes towards the contract were largely positive, although discontent was higher in the practice with a more intensive surveillance regimen. Nurses expressed more concern than doctors about changes to their clinical practice but also appreciated being given responsibility for delivering on targets in particular disease areas. Most doctors did not question the quality targets that existed at the time or the implications of the targets for their own clinical autonomy. Implementation of financial incentives for quality of care did not seem to have damaged the internal motivation of the general practitioners studied, although more concern was expressed by nurses.

  1. Dose specification and normal tissue reference points in the treatment of cancer cervix

    International Nuclear Information System (INIS)

    Ray, D.K.; Kumar, P.; Misra, D.K.; Das, R.; Kumar, A.; Maji, T.; Chaudhuri, P.; Sinha, T.P.

    2007-01-01

    Carcinoma of uterine cervix is one of the most common diseases among the women in India where radiotherapy is the mainstay of treatment. Most common practice of dose prescription point is the Manchester Point A. American Brachytherapy Society (ABS) recommends a point H equivalent to that used in the classical Manchester system. Many centre practices Madison point M as dose specification point which is 20 mm cephaled along the tandem from a line joining the mid dwell positions in the ovoids/ring and 20 mm lateral to the tandem. In the present study has compared the dose prescription points between Manchester Point A and Madison Point M for ring applicators and their implication in the assessment of rectal and bladder doses in patients of Carcinoma of uterine cervix

  2. Nano-Calorimetry based point of care biosensor for metabolic disease management.

    Science.gov (United States)

    Kazura, Evan; Lubbers, Brad R; Dawson, Elliott; Phillips, John A; Baudenbacher, Franz

    2017-09-01

    Point of care (POC) diagnostics represents one of the fastest growing health care technology segments. Developments in microfabrication have led to the development of highly-sensitive nanocalorimeters ideal for directly measuring heat generated in POC biosensors. Here we present a novel nano-calorimeter-based biosensor design with differential sensing to eliminate common mode noise and capillary microfluidic channels for sample delivery to the thermoelectric sensor. The calorimeter has a resolution of 1.4 ± 0.2 nJ/(Hz) 1/2 utilizing a 27 junction bismuth/titanium thermopile, with a total Seebeck coefficient of 2160 μV/K. Sample is wicked to the calorimeter through a capillary channel making it suitable for monitoring blood obtained through a finger prick (performance in a model assay using catalase, achieving a threshold for hydrogen peroxide quantification of 50 μM. The potential for our device as a POC blood test for metabolic diseases is shown through the quantification of phenylalanine (Phe) in serum, an unmet necessary service in the management of Phenylketonuria (PKU). Pegylated phenylalanine ammonia-lyase (PEG-PAL) was utilized to react with Phe, but reliable detection was limited to <5 mM due to low enzymatic activity. The POC biosensor concept can be multiplexed and adapted to a large number of metabolic diseases utilizing different immobilized enzymes.

  3. Linearity analysis and comparison study on the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients

    Directory of Open Access Journals (Sweden)

    Jianing Chen

    2016-03-01

    Full Text Available The epoc® blood analysis system (Epocal Inc., Ottawa, Ontario, Canada is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc® system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc® meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters.

  4. Normalization methods in time series of platelet function assays

    Science.gov (United States)

    Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham

    2016-01-01

    Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217

  5. Lactate point-of-care testing for acidosis: Cross-comparison of two devices with routine laboratory results

    Directory of Open Access Journals (Sweden)

    Remco van Horssen

    2016-04-01

    Full Text Available Objectives: Lactate is a major parameter in medical decision making. During labor, it is an indicator for fetal acidosis and immediate intervention. In the Emergency Department (ED, rapid analysis of lactate/blood gas is crucial for optimal patient care. Our objectives were to cross-compare-for the first time-two point-of-care testing (POCT lactate devices with routine laboratory results using novel tight precision targets and evaluate different lactate cut-off concentrations to predict metabolic acidosis. Design and methods: Blood samples from the delivery room (n=66 and from the ED (n=85 were analyzed on two POCT devices, the StatStrip-Lactate (Nova Biomedical and the iSTAT-1 (CG4+ cassettes, Abbott, and compared to the routine laboratory analyzer (ABL-735, Radiometer. Lactate concentrations were cross-compared between these analyzers. Results: The StatStrip correlated well with the ABL-735 (R=0.9737 and with the iSTAT-1 (R=0.9774 for lactate in umbilical cord blood. Lactate concentrations in ED samples measured on the iSTAT-1 and ABL-735 showed a correlation coefficient of R=0.9953. Analytical imprecision was excellent for lactate and pH, while for pO2 and pCO2 the coefficient of variation was relatively high using the iSTAT-1. Conclusion: Both POCT devices showed adequate analytical performance to measure lactate. The StatStrip can indicate metabolic acidosis in 1 μl blood and will be implemented at the delivery room. Keywords: Lactate, Point-of-care testing, Blood gas, Fetal acidosis

  6. BIPM project: Intercomparison of water triple-point cells

    Science.gov (United States)

    Chattle, M. V.; Butler, J.

    1994-12-01

    The paper presents the results of an intercomparison between 3 triple point of water cells circulated by the Bureau International des Poids et Measures (BIPM), and a cell which is one of those used as a reference cell at the National Physical Laboratory (NPL). All 4 cells were prepared, stored and measured in the manner normally adopted at NPL. The results of the intercomparison show that over the course of about 6 weeks the temperatures of the 3 circulated cells generally agreed within 0.20 mK, with a maximum difference of 0.27(7) mK. Over the same period, the total variations of temperature measured in the 3 individual cells were 0.04 mK, 0.08 mK and 0.18 mK, respectively; the NPL cell varied by 0.10 mK. Gallium point measurements made over a similar period confirmed that these differences were partly due to small drifts in the thermometer resistance or in the measuring system.

  7. OLED Hybrid Integrated Polymer Microfluidic Biosensing for Point of Care Testing

    Directory of Open Access Journals (Sweden)

    Ashwin Acharya

    2015-09-01

    Full Text Available This paper reports a microfluidic platform with external hybrid integration of an organic light emitting diode (OLED as an excitation source. This device can be used as a simple and cost effective biosensing element. The device is capable of rapid in-situ detection of biological elements such as sensing of interaction of antigen with fluorescent tagged antibody conjugates. These portable microfluidic systems have great potential for use an OLED in a single chip with very high accuracy and sensitivity for various point-of-care (POC diagnosis and lab on a chip (LOC applications, as the miniaturization of the biosensor is essential for handling smaller sample volumes in order to achieve high throughput. The biosensing element was successfully tested to detect anti-sheep IgG conjugates tagged to Alexafluor using a fluorescence based immunoassay method.

  8. CO-AUTHORING SCIENTIFIC PAPERS IN MANAGEMENT: INTERNATIONAL ACADEMICS’ POINTS OF VIEW

    Directory of Open Access Journals (Sweden)

    Manuel Aníbal Silva Portugal Vasconcelos Ferreira

    2015-12-01

    Full Text Available Responding to institutional pressure to publish more papers, and in respected journals, management academics are seeking to increase their productivity by establishing co-authoring ties that speed up the process, from the initial stages of defining the research question to publication in a journal. Understanding the motives, benefits and hazards of co-authorship, especially using the experiences of highly reputed scholars, may help improve the efficiency and quality of research efforts. In this paper, we examine the responses to six questions sent to thirteen prolific international researchers, by email. In essence, we sought to understand such aspects as: the origins of co-authoring ties, the importance of having co-authors, the pitfalls of and methods for coordinating co-authorships, and what constitutes a contribution that warrants co-authorship. Results show that (1 international researchers evaluate their co-authorships positively, (2 many co-authorships emerge from prior supervision or personal proximity, more so than ties to the same institution, (3 the ordering of names is defined a priori and managed actively, (4 the benefits sought after are mainly specialization and complementary competences, (5 co-authorship is given based on actual contribution, albeit there are many forms of contribution, and (6 the pressure to publish, and an increasing difficulty of publishing in the top journals are the drivers of co-authorship. The analyses point to important insights for young Brazilian scholars.

  9. Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses.

    Science.gov (United States)

    Jousi, Milla; Saikko, Simo; Nurmi, Jouni

    2017-09-11

    Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT® POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO

  10. A concept for a visual computer interface to make error taxonomies useful at the point of primary care

    Directory of Open Access Journals (Sweden)

    Ranjit Singh

    2008-01-01

    The approach is designed to capture and disseminate patient safety information in an unambiguous format that is useful to all members of the healthcare team (including the patient at the point of care as well as at the policy-making level.

  11. "Are You Done?" Child Care Providers' Verbal Communication at Mealtimes that Reinforce or Hinder Children's Internal Cues of Hunger and Satiation

    Science.gov (United States)

    Ramsay, Samantha A.; Branen, Laurel J.; Fletcher, Janice; Price, Elizabeth; Johnson, Susan L.; Sigman-Grant, Madeleine

    2010-01-01

    Objective: To explore the verbal communication of child care providers regarding preschool children's internal and non-internal hunger and satiation cues. Methods: Video observation transcripts of Head Start staff (n=29) at licensed child care centers in Colorado, Idaho, and Nevada were analyzed for common themes. Results: Adults' verbal…

  12. Point-of-Care Laboratory of Pathogen Diagnosis in Rural Senegal

    Science.gov (United States)

    Fenollar, Florence; Bassene, Hubert; Diatta, Georges; Tall, Adama; Trape, Jean-François; Drancourt, Michel; Raoult, Didier

    2013-01-01

    Background In tropical Africa, where the spectrum of the bacterial pathogens that cause fevers is poorly understood and molecular-based diagnostic laboratories are rare, the time lag between test results and patient care is a critical point for treatment of disease. Methodology/Principal Findings We implemented POC laboratory in rural Senegal to resolve the time lag between test results and patient care. During the first year of the study (February 2011 to January 2012), 440 blood specimens from febrile patients were collected in Dielmo and Ndiop villages. All samples were screened for malaria, dengue fever, Borrelia spp., Coxiella burnetii, Tropheryma whipplei, Rickettsia conorii, R. africae, R. felis, and Bartonella spp. Conclusions/Significance We identified DNA from at least one pathogenic bacterium in 80/440 (18.2%) of the samples from febrile patients. B. crocidurae was identified in 35 cases (9.5%), and R. felis DNA was found in 30 cases (6.8%). The DNA of Bartonella spp. was identified in 23/440 cases (4.3%), and DNA of C. burnetii was identified in 2 cases (0.5%). T. whipplei (0.2%) was diagnosed in one patient. No DNA of R. africae or R. conorii was identified. Among the 7 patients co-infected by two different bacteria, we found R. felis and B. crocidurae in 4 cases, B. crocidurae and Bartonella spp. in 2 cases, and B. crocidurae and C. burnetii in 1 case. Malaria was diagnosed in 54 cases. In total, at least one pathogen (bacterium or protozoa) was identified in 127/440 (28.9%) of studied samples. Here, the authors report the proof of concept of POC in rural tropical Africa. Discovering that 18.2% of acute infections can be successfully treated with doxycycline should change the treatment strategy for acute fevers in West Africa. PMID:23350001

  13. Plug-and-play paper-based toolkit for rapid prototyping of microfluidics and electronics towards point-of-care diagnostic solutions

    CSIR Research Space (South Africa)

    Smith, S

    2015-11-01

    Full Text Available We present a plug-and-play toolkit for the rapid assembly of paper-based microfluidic and electronic components for quick prototyping of paper-based components towards point-of-care diagnostic solutions. Individual modules, each with a specific...

  14. Enhancing Cross-functional Collaboration and Effective Problem Solving Through an Innovation Challenge for Point-of-Care Providers.

    Science.gov (United States)

    Bakallbashi, Eni; Vyas, Anjali; Vaswani, Nikita; Rosales, David; Russell, David; Dowding, Dawn; Bernstein, Michael; Abdelaal, Hany; Hawkey, Regina

    2015-01-01

    An internal employee challenge competition is a way to promote staff engagement and generate innovative business solutions. This Spotlight on Leadership focuses on the approach that a large not-for-profit healthcare organization, the Visiting Nurse Service of New York, took in designing and executing an innovation challenge. The challenge leveraged internal staff expertise and promoted wide participation. This model is 1 that can be replicated by organizations as leaders work to engage employees at the point of service in organization-wide problem solving.

  15. The care dependency scale for measuring basic human needs: an international comparison.

    Science.gov (United States)

    Dijkstra, Ate; Yönt, Gülendam Hakverdioğlu; Korhan, Esra Akin; Muszalik, Marta; Kędziora-Kornatowska, Kornelia; Suzuki, Mizue

    2012-10-01

    To report a study conducted to compare the utility of the care dependency scale across four countries. The care dependency scale provides a framework for assessing the needs of institutionalized patients for nursing care. Henderson's components of nursing care have been used to specify the variable aspects of the concept of care dependency and to develop the care dependency scale items. The study used a cross-cultural survey design. Patients were recruited from four different countries: Japan, The Netherlands, Poland and Turkey. In each of the participating countries, basic human needs were assessed by nurses using a translated version of the original Dutch care dependency scale. Psychometric properties in terms of reliability and validity of the care dependency scale have been assessed using Cronbach's alpha, Guttman's lambda-2, inter-item correlation and principal components analysis. Data were collected in 2008 and 2009. High internal consistency values were demonstrated. Principal component analysis confirmed the one-factor model reported in earlier studies. Outcomes confirm Henderson's idea that human needs are fundamental appearing in every patient-nurse relationship, independent of the patient's age, the type of care setting and/or cultural background. The psychometric characteristics of the care dependency scale make this instrument very useful for comparative research across countries. © 2012 Blackwell Publishing Ltd.

  16. Implementation of Point-of-Care Diagnostics Leads to Variable Uptake of Syphilis, Anemia and CD4+ T-Cell Count Testing in Rural Maternal and Child Health Clinics.

    Directory of Open Access Journals (Sweden)

    Caroline De Schacht

    Full Text Available Anemia, syphilis and HIV are high burden diseases among pregnant women in sub-Saharan Africa. A quasi-experimental study was conducted in four health facilities in Southern Mozambique to evaluate the effect of point-of-care technologies for hemoglobin quantification, syphilis testing and CD4+ T-cell enumeration performed within maternal and child health services on testing and treatment coverage, and assessing acceptability by health workers.Demographic and testing data on women attending first antenatal care services were extracted from existing records, before (2011; n = 865 and after (2012; n = 808 introduction of point-of-care testing. Study outcomes per health facility were compared using z-tests (categorical variables and Wilcoxon rank-sum test (continuous variables, while inverse variance weights were used to adjust for possible cluster effects in the pooled analysis. A structured acceptability-assessment interview was conducted with health workers before (n = 22 and after (n = 19.After implementation of point-of-care testing, there was no significant change in uptake of overall hemoglobin screening (67.9% to 83.0%; p = 0.229, syphilis screening (80.8% to 87.0%; p = 0.282 and CD4+ T-cell testing (84.9% to 83.5%; p = 0.930. Initiation of antiretroviral therapy for treatment eligible women was similar in the weighted analysis before and after, with variability among the sites. Time from HIV diagnosis to treatment initiation decreased (median of 44 days to 17 days; p<0.0001. A generally good acceptability for point-of-care testing was seen among health workers.Point-of-care CD4+ T-cell enumeration resulted in a decreased time to initiation of antiretroviral therapy among treatment eligible women, without significant increase in testing coverage. Overall hemoglobin and syphilis screening increased. Despite the perception that point-of-care technologies increase access to health services, the variability in results indicate the potential for

  17. Determining the Feasibility, Content Validity, and Internal Consistency of a Newly Developed Care Coordination Scale for People with Brain Injury

    Directory of Open Access Journals (Sweden)

    Brian P. Johnson

    2017-07-01

    Full Text Available Background: With the increasing complexity of care, people with disabilities and supportive significant others (SSO must often coordinate key aspects of their own care, but no validated scale currently exists to comprehensively characterize the activities done to manage and coordinate their care. Method: This study aimed to improve the feasibility, acceptability, and content validity of the Care and Service Coordination and Management (CASCAM scale and to test its internal consistency. Questionnaire items were administered to 23 individuals with acquired brain injury and 17 SSO. Results: Respondents confirmed content validity and that the instrument addresses important care coordination and management issues. The internal consistency of care coordination domains for medical/ rehabilitative and independent living needs for people with brain injury and their SSO ranged from α = .774 to .945. Conclusion: Care coordination activities by persons with disabilities, including brain injury, and their SSO are multifaceted but feasibly measurable and should be assessed to improve care.

  18. Laboratory Evaluation of the Alere q Point-of-Care System for Early Infant HIV Diagnosis.

    Science.gov (United States)

    Hsiao, Nei-yuan; Dunning, Lorna; Kroon, Max; Myer, Landon

    2016-01-01

    Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the "EID cascade" is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy. We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results. Overall, 1098 children with a median age of 47 days (IQR, 42-117) were included. Birth PCR (age laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower sensitivity and error rate requires further attention, as does field implementation of POC EID technologies in other clinical care settings.

  19. Health care sensor--based systems for point of care monitoring and diagnostic applications: a brief survey.

    Science.gov (United States)

    Tsakalakis, Michail; Bourbakis, Nicolaos G

    2014-01-01

    Continuous, real-time remote monitoring through medical point--of--care (POC) systems appears to draw the interest of the scientific community for healthcare monitoring and diagnostic applications the last decades. Towards this direction a significant merit has been due to the advancements in several scientific fields. Portable, wearable and implantable apparatus may contribute to the betterment of today's healthcare system which suffers from fundamental hindrances. The number and heterogeneity of such devices and systems regarding both software and hardware components, i.e sensors, antennas, acquisition circuits, as well as the medical applications that are designed for, is impressive. Objective of the current study is to present the major technological advancements that are considered to be the driving forces in the design of such systems, to briefly state the new aspects they can deliver in healthcare and finally, the identification, categorization and a first level evaluation of them.

  20. Advances in Candida detection platforms for clinical and point-of-care applications

    Science.gov (United States)

    Safavieh, Mohammadali; Coarsey, Chad; Esiobu, Nwadiuto; Memic, Adnan; Vyas, Jatin Mahesh; Shafiee, Hadi; Asghar, Waseem

    2016-01-01

    Invasive candidiasis remains one of the most serious community and healthcare-acquired infections worldwide. Conventional Candida detection methods based on blood and plate culture are time-consuming and require at least 2–4 days to identify various Candida species. Despite considerable advances for candidiasis detection, the development of simple, compact and portable point-of-care diagnostics for rapid and precise testing that automatically performs cell lysis, nucleic acid extraction, purification and detection still remains a challenge. Here, we systematically review most prominent conventional and nonconventional techniques for the detection of various Candida species, including Candida staining, blood culture, serological testing and nucleic acid-based analysis. We also discuss the most advanced lab on a chip devices for candida detection. PMID:27093473

  1. How can point-of-care HbA1c testing be integrated into UK primary care consultations? - A feasibility study.

    Science.gov (United States)

    Hirst, J A; Stevens, R J; Smith, I; James, T; Gudgin, B C; Farmer, A J

    2017-08-01

    Point-of-care (POC) HbA1c testing gives a rapid result, allowing testing and treatment decisions to take place in a single appointment. Trials of POC testing have not been shown to improve HbA1c, possibly because of how testing was implemented. This study aimed to identify key components of POC HbA1c testing and determine strategies to optimise implementation in UK primary care. This cohort feasibility study recruited thirty patients with type 2 diabetes and HbA1c>7.5% (58mmol/mol) into three primary care clinics. Patients' clinical care included two POC HbA1c tests over six months. Data were collected on appointment duration, clinical decisions, technical performance and patient behaviour. Fifty-three POC HbA1c consultations took place during the study; clinical decisions were made in 30 consultations. Five POC consultations with a family doctor lasted on average 11min and 48 consultations with nurses took on average 24min. Five POC study visits did not take place in one clinic. POC results were uploaded to hospital records from two clinics. In total, sixty-three POC tests were performed, and there were 11 cartridge failures. No changes in HbA1c or patient behaviour were observed. HbA1c measurement with POC devices can be effectively implemented in primary care. This work has identified when these technologies might work best, as well as potential challenges. The findings can be used to inform the design of a pragmatic trial to implement POC HbA1c testing. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  2. A flexible mobile-device biosensing instrumentation platform for point-of-care medical diagnostics applications

    DEFF Research Database (Denmark)

    Patou, François; Pfreundt, Andrea; Zulfiqar, Azeem

    2014-01-01

    helping to address this challenge. Specifically, Lab-on-Chip (LoC) devices have a key role to play in the advent of Point-of-Care (PoC) medical applications, driving a shift of the medical diagnostics paradigm and the transition from a centralized, technical, high-throughput biological sample analysis...... programmable electrical readout from LoCs potentially comprehending varied transducers addressing different targeted biological markers. A smart-phone/tablet docking-station embeds the hardware interface necessary for the implementation of a smart-phone digital lock-in amplifier. The platform is tested...

  3. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    Science.gov (United States)

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  4. The promotion of olanzapine in primary care: an examination of internal industry documents.

    Science.gov (United States)

    Spielmans, Glen I

    2009-07-01

    Media reports have discussed how olanzapine was marketed off-label for dementia and subsyndromal bipolar disorder. Much of this marketing occurred in primary care settings. However, these reports have provided few details. In legal proceedings, Lilly disclosed internal documents that detail the strategies utilized to market olanzapine. The current paper addresses the marketing of olanzapine in detail based upon a review of these documents. All 358 documents released by Lilly are publicly available online. Documents were utilized for this review if they were relevant to the marketing of olanzapine in primary care settings in the United States. It was found that olanzapine was marketed off-label in primary care settings for relatively mild symptoms that were framed as bipolar disorder and schizophrenia. A key strategy in this campaign was the use of hypothetical patient profiles in detailing visits, most of which clearly failed to meet diagnostic criteria for any recognized mental disorder. Evidence emerged that olanzapine was also marketed off-label as a treatment for dementia.

  5. Advances in paper-based sample pretreatment for point-of-care testing.

    Science.gov (United States)

    Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng

    2017-06-01

    In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.

  6. Use of a centrifugation-based, point-of-care device for production of canine autologous bone marrow and platelet concentrates.

    Science.gov (United States)

    Thoesen, Michael S; Berg-Foels, Wendy S Vanden; Stokol, Tracy; Rassnick, Kenneth M; Jacobson, May S; Kevy, Sherwin V; Todhunter, Rory J

    2006-10-01

    To analyze a centrifugation-based, point-of-care device that concentrates canine platelets and bone marrow-derived cells. 19 adult sexually intact dogs. Anticoagulated peripheral blood (60 mL) and 60 mL of anticoagulated bone marrow aspirate (BMA) were concentrated by centrifugation with the centrifugation-based, point-of-care device to form a platelet and a bone marrow concentrate (BMC) from 11 dogs. Blood samples were analyzed on the basis of hemograms, platelet count, and PCV. The BMA and BMC were analyzed to determine PCV, total nucleated cell count, RBC count, and differential cell counts. The BMC stromal cells were cultured in an osteoinductive medium. Eight additional dogs were used to compare the BMC yield with that in which heparin was infused into the bone marrow before aspiration. The centrifugation-based, point-of-care device concentrated platelets by 6-fold over baseline (median recovery, 63.1%) with a median of 1,336 x 10(3) platelets/microL in the 7-mL concentrate. The nucleated cells in BMCs increased 7-fold (median recovery, 42.9%) with a median of 720 x 10(3) cells/microL in the 4-mL concentrate. The myeloid nucleated cells and mononuclear cells increased significantly in BMCs with a significant decrease in PCV, compared with that of BMAs. Stromal cell cultures expressed an osteoblastic phenotype in culture. Infusion of heparin into the bone marrow eliminated clot formation and created less variation in the yield (median recovery, 61.9%). Bone marrow-derived cell and platelet-rich concentrates may form bone if delivered in an engineered graft, thus decreasing the need for cancellous bone grafts.

  7. The International Glossary on Infertility and Fertility Care, 2017

    DEFF Research Database (Denmark)

    Zegers-Hochschild, Fernando; Adamson, G. David; Dyer, Silke

    2017-01-01

    : Twenty-five professionals, from all parts of the world and representing their expertise in a variety of sub-specialties, were organized into five working groups: clinical definitions; outcome measurements; embryology laboratory; clinical and laboratory andrology; and epidemiology and public health...... and representatives of international/regional scientific and patient organizations. MAIN RESULTS AND THE ROLE OF CHANCE: A consensus-based and evidence-driven set of 283 terminologies used in infertility and fertility care was generated to harmonize communication among health professionals and scientists as well...

  8. Routine use of point-of-care tests: usefulness and application in clinical microbiology.

    Science.gov (United States)

    Clerc, O; Greub, G

    2010-08-01

    Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

  9. Postanalytical external quality assessment of urine albumin in primary health care: An international survey

    DEFF Research Database (Denmark)

    Aakre, K.M.; Thue, G.; Subramaniam-Haavik, S.

    2008-01-01

    BACKGROUND: Microalbuminuria (MA) is recognized as an important risk factor for cardiovascular and renal complications in diabetes. We sought to evaluate how screening for MA is conducted and how urine albumin (UA) results are interpreted in primary care internationally. METHODS: General practiti...

  10. HIV Point-of-Care Testing in Canadian Settings: A Scoping Review.

    Science.gov (United States)

    Minichiello, Alexa; Swab, Michelle; Chongo, Meck; Marshall, Zack; Gahagan, Jacqueline; Maybank, Allison; Hot, Aurélie; Schwandt, Michael; Gaudry, Sonia; Hurley, Oliver; Asghari, Shabnam

    2017-01-01

    HIV point-of-care testing (POCT) was approved for use in Canada in 2005 and provides important public health benefits by providing rapid screening results rather than sending a blood sample to a laboratory and waiting on test results. Access to test results soon after testing (or during the same visit) is believed to increase the likelihood that individuals will receive their results and improve access to confirmatory testing and linkages to care. This paper reviews the literature on the utilization of HIV POCT across Canadian provinces. We searched OVID Medline, Embase, EBM Reviews, PsycINFO, CINAHL, and 20 electronic grey literature databases. All empirical studies investigating HIV POCT programs in Canada published in French or English were included. Searches of academic databases identified a total of 6,091 records. After removing duplicates and screening for eligibility, 27 records were included. Ten studies are peer-reviewed articles, and 17 are grey literature reports. HIV POCT in Canada is both feasible and accepted by Canadians. It is preferred to conventional HIV testing (ranging from 81.1 to 97%), and users are highly satisfied with the testing process (ranging between 96 and 100%). The majority of studies demonstrate that HIV POCT is feasible, preferred, and accepted by diverse populations in Canada. Losses to follow-up and linkage rates are also good. However, more research is needed to understand how best to scale up HIV POCT in contexts that currently have very limited or no access to testing.

  11. Point-of-care genetic testing for personalisation of antiplatelet treatment (RAPID GENE): a prospective, randomised, proof-of-concept trial.

    Science.gov (United States)

    Roberts, Jason D; Wells, George A; Le May, Michel R; Labinaz, Marino; Glover, Chris; Froeschl, Michael; Dick, Alexander; Marquis, Jean-Francois; O'Brien, Edward; Goncalves, Sandro; Druce, Irena; Stewart, Alexandre; Gollob, Michael H; So, Derek Y F

    2012-05-05

    Prospective assessment of pharmacogenetic strategies has been limited by an inability to undertake bedside genetic testing. The CYP2C19*2 allele is a common genetic variant associated with increased rates of major adverse events in individuals given clopidogrel after percutaneous coronary intervention (PCI). We used a novel point-of-care genetic test to identify carriers of the CYP2C19*2 allele and aimed to assess a pharmacogenetic approach to dual antiplatelet treatment after PCI. Between Aug 26, 2010, and July 7, 2011, 200 patients were enrolled into our prospective, randomised, proof-of-concept study. Patients undergoing PCI for acute coronary syndrome or stable angina were randomly assigned to rapid point-of-care genotyping or to standard treatment. Individuals in the rapid genotyping group were screened for the CYP2C19*2 allele. Carriers were given 10 mg prasugrel daily, and non-carriers and patients in the standard treatment group were given 75 mg clopidogrel daily. The primary endpoint was the proportion of CYP2C19*2 carriers with high on-treatment platelet reactivity (P2Y12 reactivity unit [PRU] value of more than 234) after 1 week of dual antiplatelet treatment, which is a marker associated with increased adverse cardiovascular events. Interventional cardiologists and data analysts were masked to genetic status and treatment. Patients were not masked to treatment allocation. All analyses were by intention to treat. This study is registered with ClinicalTrials.gov, NCT01184300. After randomisation, 187 patients completed follow-up (91 rapid genotyping group, 96 standard treatment). 23 individuals in each group carried at least one CYP2C19*2 allele. None of the 23 carriers in the rapid genotyping group had a PRU value of more than 234 at day 7, compared with seven (30%) given standard treatment (p=0·0092). The point-of-care genetic test had a sensitivity of 100% (95% CI 92·3-100) and a specificity of 99·3% (96·3-100). Point-of-care genetic testing after

  12. Accuracy of Point-of-care Ultrasonography for Diagnosing Acute Appendicitis: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Matthew Fields, J; Davis, Joshua; Alsup, Carl; Bates, Amanda; Au, Arthur; Adhikari, Srikar; Farrell, Isaac

    2017-09-01

    The use of ultrasonography (US) to diagnose appendicitis is well established. More recently, point-of-care ultrasonography (POCUS) has also been studied for the diagnosis of appendicitis, which may also prove a valuable diagnostic tool. The purpose of this study was through systematic review and meta-analysis to identify the test characteristics of POCUS, specifically US performed by a nonradiologist physician, in accurately diagnosing acute appendicitis in patients of any age. We conducted a thorough and systematic literature search of English language articles published on point-of-care, physician-performed transabdominal US used for the diagnosis of acute appendicitis from 1980 to May, 2015 using OVID MEDLINE In-Process & Other Non-indexed Citations and Scopus. Studies were selected and subsequently independently abstracted by two trained reviewers. A random-effects pooled analysis was used to construct a hierarchical summary receiver operator characteristic curve, and a meta-regression was performed. Quality of studies was assessed using the QUADAS-2 tool. Our search yielded 5,792 unique studies and we included 21 of these in our final review. Prevalence of disease in this study was 29.8%, (range = 6.4%-75.4%). The sensitivity and specificity for POCUS in diagnosing appendicitis were 91% (95% confidence interval [CI] = 83%-96%) and 97% (95% CI = 91%-99%), respectively. The positive and negative predictive values were 91 and 94%, respectively. Studies performed by emergency physicians had slightly lower test characteristics (sensitivity = 80%, specificity = 92%). There was significant heterogeneity between studies (I 2 = 99%, 95% CI = 99%-100%) and the quality of the reported studies was moderate, mostly due to unclear reporting of blinding of physicians and timing of scanning and patient enrollment. Several of the studies were performed by a single operator, and the education and training of the operators were variably reported. Point-of-care US has relatively

  13. Planning for the integration of the digital library, clinical decision support, and evidence at the point of care.

    Science.gov (United States)

    Schwartz, Linda Matula; Iobst, Barbara

    2008-01-01

    Integrating knowledge-based resources at the point of care is an important opportunity for hospital library involvement. In the progression of an IAIMS planning grant, the digital library is recognized as pivotal to the success of information domain integration throughout the institution. The planning process, data collection, and evolution of the planning project are discussed.

  14. Adherence of preventive oral care products in the Syrian market to evidence-based international recommendations.

    Science.gov (United States)

    Habes, D; Mahzia, R; Nakhleh, K; Joury, E

    2016-09-25

    No study has investigated the availability and adherence of preventive oral care products on the Syrian market to evidence-based international recommendations. Data were collected in 2012, and updated in 2016, in terms of availability, characteristics and adherence to evidence-based international recommendations. Few preventive products adhered to the recommendations. Despite the large decrease in the number of oral care products on the Syrian market, due to the Syrian crisis, nonadherence of some of the available products is still present. A multisectorial approach at a policy level is needed to address such important limitations. The Syrian Ministry of Health should reform regulations for fluoride products to become subject to drug monitoring systems; the Syrian Arab Committee for Measurements and Standards needs to update its standards; and the Syrian General Dental Association should distribute a preventive booklet to dental practitioners.

  15. A systematic review of the international published literature relating to quality of institutional care for people with longer term mental health problems

    NARCIS (Netherlands)

    Taylor, T.L.; Killaspy, H.; Wright, C.; Turton, P.; White, S.; Kallert, T.W.; Schuster, M.; Cervilla, J.A.; Brangier, P.; Raboch, J.; Kalisova, L.; Onchev, G.; Dimitrov, H.; Mezzina, R.; Wolf, Kinou; Wiersma, D.; Visser, E.; Kiejna, A.; Piotrowski, P.; Ploumpidis, D.; Gonidakis, F.; Caldas-de-Almeida, J.; Cardoso, G.; King, M.B.

    2009-01-01

    Background: A proportion of people with mental health problems require longer term care in a psychiatric or social care institution. However, there are no internationally agreed quality standards for institutional care and no method to assess common care standards across countries. We aimed to

  16. Equipment-free nucleic acid extraction and amplification on a simple paper disc for point-of-care diagnosis of rotavirus A.

    Science.gov (United States)

    Ye, Xin; Xu, Jin; Lu, Lijuan; Li, Xinxin; Fang, Xueen; Kong, Jilie

    2018-08-14

    The use of paper-based methods for clinical diagnostics is a rapidly expanding research topic attracting a great deal of interest. Some groups have attempted to realize an integrated nucleic acid test on a single microfluidic paper chip, including extraction, amplification, and readout functions. However, these studies were not able to overcome complex modification and fabrication requirements, long turn-around times, or the need for sophisticated equipment like pumps, thermal cyclers, or centrifuges. Here, we report an extremely simple paper-based test for the point-of-care diagnosis of rotavirus A, one of the most common pathogens that causes pediatric gastroenteritis. This paper-based test could perform nucleic acid extraction within 5 min, then took 25 min to amplify the target sequence, and the result was visible to the naked eye immediately afterward or quantitative by the UV-Vis absorbance. This low-cost method does not require extra equipment and is easy to use either in a lab or at the point-of-care. The detection limit for rotavirus A was found to be 1 × 10 3 copies/mL. In addition, 100% sensitivity and specificity were achieved when testing 48 clinical stool samples. In conclusion, the present paper-based test fulfills the main requirements for a point-of-care diagnostic tool, and has the potential to be applied to disease prevention, control, and precision diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Different percentages of false-positive results obtained using five methods for the calculation of reference change values based on simulated normal and ln-normal distributions of data

    DEFF Research Database (Denmark)

    Lund, Flemming; Petersen, Per Hyltoft; Fraser, Callum G

    2016-01-01

    a homeostatic set point that follows a normal (Gaussian) distribution. This set point (or baseline in steady-state) should be estimated from a set of previous samples, but, in practice, decisions based on reference change value are often based on only two consecutive results. The original reference change value......-positive results. The aim of this study was to investigate false-positive results using five different published methods for calculation of reference change value. METHODS: The five reference change value methods were examined using normally and ln-normally distributed simulated data. RESULTS: One method performed...... best in approaching the theoretical false-positive percentages on normally distributed data and another method performed best on ln-normally distributed data. The commonly used reference change value method based on two results (without use of estimated set point) performed worst both on normally...

  18. Team knowledge assessment of nursing on international targets patient safety in an intensive care unit

    Directory of Open Access Journals (Sweden)

    Maria Nathália da Silva Souza

    2017-08-01

    Full Text Available Background e Objectives: The quality of hospital care provided to the patient and the safety of their stay at the site triggered discussions around the world after the analysis of epidemiological studies conducted in the USA that concluded the high rate of adverse events in the hospital setting Caused by professional error, with that the theme gained strength and motivated discussions about the care models applied to the patients. Therefore the research was aimed at evaluating the knowledge of the Nursing Team of the Intensive Care Unit sector of a public hospital in Recife-PE on the International Patient Safety Goals. Methods: A cross-sectional study with descriptive quantitative approach was carried out from June to August 2016. Data collection was performed through a semi-structured questionnaire that addressed the social and professional aspects of the respondents. The studied variables: gender, age, professional category and training time. The data were analyzed in epiinfo software version 3.2.2. Results: The sample consisted of 50 professionals, 18% of whom were Nurses and 82% were Nursing technicians. Most respondents scored more than 50% of questions about international patient safety goals and had more than one employment relationship. Conclusion: It was verified that the lack of training, work overload and more of an employment relationship can contribute to a precarious professional assistance. KEYWORDS: Patient Safety. Nursing. Safety Management. Intensive Care Units

  19. Late effects of normal tissues (lent) scoring system: the soma scale

    International Nuclear Information System (INIS)

    Mornex, F.; Pavy, J.J.; Denekamp, J.

    1997-01-01

    Radiation tolerance of normal tissues remains the limiting factor for delivering tumoricidal dose. The late toxicity of normal tissues is the most critical element of an irradiation: somatic, functional and structural alterations occur during the actual treatment itself, but late effects manifest months to years after acute effects heal, and may progress with time. The optimal therapeutic ratio ultimately requires not only complete tumor clearance, but also minimal residual injury to surrounding vital normal tissues. The disparity between the intensity of acute and late effects and the inability to predict the eventual manifestation of late normal tissue injury has made radiation oncologists recognize the importance of careful patient follow-up. There is so far no uniform toxicity scoring system to compare several clinical studies in the absence of a 'common toxicity language'. This justifies the need to establish a precise evaluation system for the analysis of late effects of radiation on normal tissues. The SOMA/LENT scoring system results from an international collaboration. European Organization Treatment of Cancer (EORTC) and Radiation Therapy Oncology Group (RTOG) have created subcommittees with the aim of addressing the question of standardized toxic effects criteria. This effort appeared as a necessity to standardize and improve the data recording, to then describe and evaluate uniform toxicity at regular time intervals. The current proposed scale is not yet validated, and should be used cautiously. (authors)

  20. Development of a magnetic lab-on-a-chip for point-of-care sepsis diagnosis

    International Nuclear Information System (INIS)

    Schotter, Joerg; Shoshi, Astrit; Brueckl, Hubert

    2009-01-01

    We present design criteria, operation principles and experimental examples of magnetic marker manipulation for our magnetic lab-on-a-chip prototype. It incorporates both magnetic sample preparation and detection by embedded GMR-type magnetoresistive sensors and is optimized for the automated point-of-care detection of four different sepsis-indicative cytokines directly from about 5 μl of whole blood. The sample volume, magnetic particle size and cytokine concentration determine the microfluidic volume, sensor size and dimensioning of the magnetic gradient field generators. By optimizing these parameters to the specific diagnostic task, best performance is expected with respect to sensitivity, analysis time and reproducibility.

  1. Simple Approaches to Minimally-Instrumented, Microfluidic-Based Point-of-Care Nucleic Acid Amplification Tests

    Science.gov (United States)

    Mauk, Michael G.; Song, Jinzhao; Liu, Changchun; Bau, Haim H.

    2018-01-01

    Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges (‘chips’) that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed. PMID:29495424

  2. Simple Approaches to Minimally-Instrumented, Microfluidic-Based Point-of-Care Nucleic Acid Amplification Tests

    Directory of Open Access Journals (Sweden)

    Michael G. Mauk

    2018-02-01

    Full Text Available Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC tests for resource-limited settings. Microfluidic cartridges (‘chips’ that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets is demonstrated. Low-cost detection and added functionality (data analysis, control, communication can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed.

  3. Effects of duty hour restrictions on core competencies, education, quality of life, and burnout among general surgery interns.

    Science.gov (United States)

    Antiel, Ryan M; Reed, Darcy A; Van Arendonk, Kyle J; Wightman, Sean C; Hall, Daniel E; Porterfield, John R; Horvath, Karen D; Terhune, Kyla P; Tarpley, John L; Farley, David R

    2013-05-01

    To measure the implications of the new Accreditation Council for Graduate Medical Education duty hour regulations for education, well-being, and burnout. Longitudinal study. Eleven university-based general surgery residency programs from July 2011 to May 2012. Two hundred thirteen surgical interns. Perceptions of the impact of the new duty hours on various aspects of surgical training, including the 6 Accreditation Council for Graduate Medical Education core competencies, were measured on 3-point scales. Quality of life, burnout, balance between personal and professional life, and career satisfaction were measured using validated instruments. Half of all interns felt that the duty hour changes have decreased the coordination of patient care (53%), their ability to achieve continuity with hospitalized patients (70%), and their time spent in the operating room (57%). Less than half (44%) of interns believed that the new standards have decreased resident fatigue. In longitudinal analysis, residents' beliefs had significantly changed in 2 categories: less likely to believe that practice-based learning and improvement had improved and more likely to report no change to resident fatigue (P life. Compared with the normal US population, 50 interns (32%) were 0.5 SD less than the mean on the 8-item Short Form Health Survey mental quality of life score. Approximately one-third of interns demonstrated weekly symptoms of emotional exhaustion (28%) or depersonalization (28%) or reported that their personal-professional balance was either "very poor" or "not great" (32%). Although many interns (67%) reported that they daily or weekly reflect on their satisfaction from being a surgeon, 1 in 7 considered giving up their career as a surgeon on at least a weekly basis. The first cohort of surgical interns to train under the new regulations report decreased continuity with patients, coordination of patient care, and time spent in the operating room. Furthermore, suboptimal quality of

  4. Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle.

    Science.gov (United States)

    Megahed, A A; Hiew, M W H; Townsend, J R; Messick, J B; Constable, P D

    2015-01-01

    The Precision Xtra(®) meter is a promising low cost electrochemical point-of-care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra-erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. The primary objective was to determine the accuracy of the meter for measuring plasma [gluc] in dairy cattle. Secondary objectives were to characterize the influence of hematocrit and sample temperature on the measured value for [gluc]. A total of 106 periparturient Holstein-Friesian cattle. Blood and plasma samples (1,109) were obtained and Deming regression and Bland-Altman plots were used to determine the accuracy of the meter against the reference method (plasma hexokinase assay). Multivariable regression and linear regression were used to determine the effect of hematocrit and sample temperature on the plasma [gluc] measured by the meter. Intra-erythrocyte [gluc] was 18% of plasma [gluc] on a molar basis. Sample temperature had a significant linear effect on plasma [gluc] as measured by the meter for 3/5 plasma samples when measured [gluc] > 160 mg/dL. The meter utilizes an algorithm that is optimized for human blood and is inaccurate when applied to bovine blood. Until a cattle-specific algorithm is developed, we recommend using plasma as the analyte instead of blood and calculating plasma [gluc] using the equation: [gluc] = 0.66 × [gluc]p-meter + 15, where [gluc]p-meter is the value reported by the meter. If blood is measured, then we recommend using the equation: [gluc] = 0.90 × [gluc]b-meter + 15. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. Prevalence of Internalized HIV-Related Stigma Among HIV-Infected Adults in Care, United States, 2011-2013.

    Science.gov (United States)

    Baugher, Amy R; Beer, Linda; Fagan, Jennifer L; Mattson, Christine L; Freedman, Mark; Skarbinski, Jacek; Shouse, R Luke

    2017-09-01

    HIV-infected U.S. adults have reported internalized HIV-related stigma; however, the national prevalence of stigma is unknown. We sought to determine HIV-related stigma prevalence among adults in care, describe which socio-demographic groups bear the greatest stigma burden, and assess the association between stigma and sustained HIV viral suppression. The Medical Monitoring Project measures characteristics of U.S. HIV-infected adults receiving care using a national probability sample. We used weighted data collected from June 2011 to May 2014 and assessed self-reported internalized stigma based on agreement with six statements. Overall, 79.1% endorsed ≥1 HIV-related stigma statements (n = 13,841). The average stigma score was 2.4 (out of a possible high score of six). White males had the lowest stigma scores while Hispanic/Latina females and transgender persons who were multiracial or other race had the highest. Although stigma was associated with viral suppression, it was no longer associated after adjusting for age. Stigma was common among HIV-infected adults in care. Results suggest individual and community stigma interventions may be needed, particularly among those who are Stigma was not independently associated with viral suppression; however, this sample was limited to adults in care. Examining HIV-infected persons not in care may elucidate stigma's association with viral suppression.

  6. Comparative effectiveness research in DARTNet primary care practices: point of care data collection on hypoglycemia and over-the-counter and herbal use among patients diagnosed with diabetes.

    Science.gov (United States)

    Libby, Anne M; Pace, Wilson; Bryan, Cathy; Anderson, Heather Orton; Ellis, Samuel L; Allen, Richard Read; Brandt, Elias; Huebschmann, Amy G; West, David; Valuck, Robert J

    2010-06-01

    The Distributed Ambulatory Research in Therapeutics Network (DARTNet) is a federated network of electronic health record (EHR) data, designed as a platform for next-generation comparative effectiveness research in real-world settings. DARTNet links information from nonintegrated primary care clinics that use EHRs to deliver ambulatory care to overcome limitations with traditional observational research. Test the ability to conduct a remote, electronic point of care study in DARTNet practices by prompting clinic staff to obtain specific information during a patient encounter. Prospective survey of patients identified through queries of clinical data repositories in federated network organizations. On patient visit, survey is triggered and data are relinked to the EHR, de-identified, and copied for evaluation. Adult patients diagnosed with diabetes mellitus that scheduled a clinic visit for any reason in a 2-week period in DARTNet primary care practices. Survey on hypoglycemic events (past month) and over-the-counter and herbal supplement use. DARTNet facilitated point of care data collection triggered by an electronic prompt for additional information at a patient visit. More than one-third of respondents (33% response rate) reported either mild (45%) or severe hypoglycemic events (5%) in the month before the survey; only 3 of those were also coded using the ICD-9 (a significant difference in detection rates 37% vs. 1%). Nearly one-quarter of patients reported taking an OTC/herbal, 4% specifically for the treatment of symptoms of diabetes. Prospective data collection is feasible in DARTNet and can enable comparative effectiveness and safety research.

  7. Simultaneous point-of-care detection of anemia and sickle cell disease in Tanzania: the RAPID study.

    Science.gov (United States)

    Smart, Luke R; Ambrose, Emmanuela E; Raphael, Kevin C; Hokororo, Adolfine; Kamugisha, Erasmus; Tyburski, Erika A; Lam, Wilbur A; Ware, Russell E; McGann, Patrick T

    2018-02-01

    Both anemia and sickle cell disease (SCD) are highly prevalent across sub-Saharan Africa, and limited resources exist to diagnose these conditions quickly and accurately. The development of simple, inexpensive, and accurate point-of-care (POC) assays represents an important advance for global hematology, one that could facilitate timely and life-saving medical interventions. In this prospective study, Robust Assays for Point-of-care Identification of Disease (RAPID), we simultaneously evaluated a POC immunoassay (Sickle SCAN™) to diagnose SCD and a first-generation POC color-based assay to detect anemia. Performed at Bugando Medical Center in Mwanza, Tanzania, RAPID tested 752 participants (age 1 day to 20 years) in four busy clinical locations. With minimally trained medical staff, the SCD POC assay diagnosed SCD with 98.1% sensitivity and 91.1% specificity. The hemoglobin POC assay had 83.2% sensitivity and 74.5% specificity for detection of severe anemia (Hb ≤ 7 g/dL). Interobserver agreement was excellent for both POC assays (r = 0.95-0.96). Results for the hemoglobin POC assay have informed the second-generation assay design to be more suitable for low-resource settings. RAPID provides practical feasibility data regarding two novel POC assays for the diagnosis of anemia and SCD in real-world field evaluations and documents the utility and potential impact of these POC assays for sub-Saharan Africa.

  8. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    Science.gov (United States)

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  9. Developing a Patient Care Co-ordination Centre in Trafford, England: lessons from the International Foundation for Integrated Care (IFIC/Advancing Quality Alliance integrated care fellowship experience

    Directory of Open Access Journals (Sweden)

    Michael Gregory

    2015-05-01

    Full Text Available The NHS and Social Care in England are facing one of the biggest financial challenges for a generation. Commissioners and providers need to work on collaborative schemes to manage the increasing demand on health and social care within a period of financial constraint. Different forms of care co-ordination have been developed at different levels across the world.In the north-west of England, the Trafford health and social care economy have been working through a competitive dialogue process with industry to develop an innovative and dynamic solution to deliver seamless co-ordination for all patients and service users. The strategy is to develop a new Patient Care Co-ordination Centre, which will be responsible for the delivery of co-ordinated, quality care. The Patient Care Co-ordination Centre will work at clinical, service, functional and community levels across multiple providers covering risk stratification, preventative, elective and unscheduled care.I am the clinical lead for the Patient Care Co-ordination Centre and during my year as an Advancing Quality Alliance Integrated Care Fellow, I have had the opportunity to study examples of care coordination from UK and international sites. The learning from these visits has been assimilated into the design process of the Patient Care Co-ordination Centre.

  10. Developing a Patient Care Co-ordination Centre in Trafford, England: lessons from the International Foundation for Integrated Care (IFIC)/Advancing Quality Alliance integrated care fellowship experience.

    Science.gov (United States)

    Gregory, Michael

    2015-01-01

    The NHS and Social Care in England are facing one of the biggest financial challenges for a generation. Commissioners and providers need to work on collaborative schemes to manage the increasing demand on health and social care within a period of financial constraint. Different forms of care co-ordination have been developed at different levels across the world. In the north-west of England, the Trafford health and social care economy have been working through a competitive dialogue process with industry to develop an innovative and dynamic solution to deliver seamless co-ordination for all patients and service users. The strategy is to develop a new Patient Care Co-ordination Centre, which will be responsible for the delivery of co-ordinated, quality care. The Patient Care Co-ordination Centre will work at clinical, service, functional and community levels across multiple providers covering risk stratification, preventative, elective and unscheduled care. I am the clinical lead for the Patient Care Co-ordination Centre and during my year as an Advancing Quality Alliance Integrated Care Fellow, I have had the opportunity to study examples of care coordination from UK and international sites. The learning from these visits has been assimilated into the design process of the Patient Care Co-ordination Centre.

  11. Developing a Patient Care Co-ordination Centre in Trafford, England: lessons from the International Foundation for Integrated Care (IFIC/Advancing Quality Alliance integrated care fellowship experience

    Directory of Open Access Journals (Sweden)

    Michael Gregory

    2015-05-01

    Full Text Available The NHS and Social Care in England are facing one of the biggest financial challenges for a generation. Commissioners and providers need to work on collaborative schemes to manage the increasing demand on health and social care within a period of financial constraint. Different forms of care co-ordination have been developed at different levels across the world. In the north-west of England, the Trafford health and social care economy have been working through a competitive dialogue process with industry to develop an innovative and dynamic solution to deliver seamless co-ordination for all patients and service users. The strategy is to develop a new Patient Care Co-ordination Centre, which will be responsible for the delivery of co-ordinated, quality care. The Patient Care Co-ordination Centre will work at clinical, service, functional and community levels across multiple providers covering risk stratification, preventative, elective and unscheduled care. I am the clinical lead for the Patient Care Co-ordination Centre and during my year as an Advancing Quality Alliance Integrated Care Fellow, I have had the opportunity to study examples of care coordination from UK and international sites. The learning from these visits has been assimilated into the design process of the Patient Care Co-ordination Centre.

  12. Development of the Migrant Friendly Maternity Care Questionnaire (MFMCQ) for migrants to Western societies: an international Delphi consensus process

    Science.gov (United States)

    2014-01-01

    Background Through the World Health Assembly Resolution, ‘Health of Migrants’, the international community has identified migrant health as a priority. Recommendations for general hospital care for international migrants in receiving-countries have been put forward by the Migrant Friendly Hospital Initiative; adaptations of these recommendations specific to maternity care have yet to be elucidated and validated. We aimed to develop a questionnaire measuring migrant-friendly maternity care (MFMC) which could be used in a range of maternity care settings and countries. Methods This study was conducted in four stages. First, questions related to migrant friendly maternity care were identified from existing questionnaires including the Migrant Friendliness Quality Questionnaire, developed in Europe to capture recommended general hospital care for migrants, and the Mothers In a New Country (MINC) Questionnaire, developed in Australia and revised for use in Canada to capture the maternity care experiences of migrant women, and combined to create an initial MFMC questionnaire. Second, a Delphi consensus process in three rounds with a panel of 89 experts in perinatal health and migration from 17 countries was undertaken to identify priority themes and questions as well as to clarify wording and format. Third, the draft questionnaire was translated from English to French and Spanish and back-translated and subsequently culturally validated (assessed for cultural appropriateness) by migrant women. Fourth, the questionnaire was piloted with migrant women who had recently given birth in Montreal, Canada. Results A 112-item questionnaire on maternity care from pregnancy, through labour and birth, to postpartum care, and including items on maternal socio-demographic, migration and obstetrical characteristics, and perceptions of care, has been created - the Migrant Friendly Maternity Care Questionnaire (MFMCQ) – in three languages (English, French and Spanish). It is

  13. Development of the Migrant Friendly Maternity Care Questionnaire (MFMCQ) for migrants to Western societies: an international Delphi consensus process.

    Science.gov (United States)

    Gagnon, Anita J; DeBruyn, Rebecca; Essén, Birgitta; Gissler, Mika; Heaman, Maureen; Jeambey, Zeinab; Korfker, Dineke; McCourt, Christine; Roth, Carolyn; Zeitlin, Jennifer; Small, Rhonda

    2014-06-10

    Through the World Health Assembly Resolution, 'Health of Migrants', the international community has identified migrant health as a priority. Recommendations for general hospital care for international migrants in receiving-countries have been put forward by the Migrant Friendly Hospital Initiative; adaptations of these recommendations specific to maternity care have yet to be elucidated and validated. We aimed to develop a questionnaire measuring migrant-friendly maternity care (MFMC) which could be used in a range of maternity care settings and countries. This study was conducted in four stages. First, questions related to migrant friendly maternity care were identified from existing questionnaires including the Migrant Friendliness Quality Questionnaire, developed in Europe to capture recommended general hospital care for migrants, and the Mothers In a New Country (MINC) Questionnaire, developed in Australia and revised for use in Canada to capture the maternity care experiences of migrant women, and combined to create an initial MFMC questionnaire. Second, a Delphi consensus process in three rounds with a panel of 89 experts in perinatal health and migration from 17 countries was undertaken to identify priority themes and questions as well as to clarify wording and format. Third, the draft questionnaire was translated from English to French and Spanish and back-translated and subsequently culturally validated (assessed for cultural appropriateness) by migrant women. Fourth, the questionnaire was piloted with migrant women who had recently given birth in Montreal, Canada. A 112-item questionnaire on maternity care from pregnancy, through labour and birth, to postpartum care, and including items on maternal socio-demographic, migration and obstetrical characteristics, and perceptions of care, has been created--the Migrant Friendly Maternity Care Questionnaire (MFMCQ)--in three languages (English, French and Spanish). It is completed in 45 minutes via interview

  14. Robust Seismic Normal Modes Computation in Radial Earth Models and A Novel Classification Based on Intersection Points of Waveguides

    Science.gov (United States)

    Ye, J.; Shi, J.; De Hoop, M. V.

    2017-12-01

    We develop a robust algorithm to compute seismic normal modes in a spherically symmetric, non-rotating Earth. A well-known problem is the cross-contamination of modes near "intersections" of dispersion curves for separate waveguides. Our novel computational approach completely avoids artificial degeneracies by guaranteeing orthonormality among the eigenfunctions. We extend Wiggins' and Buland's work, and reformulate the Sturm-Liouville problem as a generalized eigenvalue problem with the Rayleigh-Ritz Galerkin method. A special projection operator incorporating the gravity terms proposed by de Hoop and a displacement/pressure formulation are utilized in the fluid outer core to project out the essential spectrum. Moreover, the weak variational form enables us to achieve high accuracy across the solid-fluid boundary, especially for Stoneley modes, which have exponentially decaying behavior. We also employ the mixed finite element technique to avoid spurious pressure modes arising from discretization schemes and a numerical inf-sup test is performed following Bathe's work. In addition, the self-gravitation terms are reformulated to avoid computations outside the Earth, thanks to the domain decomposition technique. Our package enables us to study the physical properties of intersection points of waveguides. According to Okal's classification theory, the group velocities should be continuous within a branch of the same mode family. However, we have found that there will be a small "bump" near intersection points, which is consistent with Miropol'sky's observation. In fact, we can loosely regard Earth's surface and the CMB as independent waveguides. For those modes that are far from the intersection points, their eigenfunctions are localized in the corresponding waveguides. However, those that are close to intersection points will have physical features of both waveguides, which means they cannot be classified in either family. Our results improve on Okal

  15. Communication About Advance Directives and End-of-Life Care Options Among Internal Medicine Residents

    Science.gov (United States)

    Rhodes, Ramona L.; Tindall, Kate; Xuan, Lei; Paulk, M. Elizabeth; Halm, Ethan A.

    2015-01-01

    Background Despite increasing awareness about the importance of discussing end-of-life (EOL) care options with terminally ill patients and families, many physicians remain uncomfortable with these discussions. Objective The objective of the study was to examine perceptions of and comfort with EOL care discussions among a group of internal medicine residents and the extent to which comfort with these discussions has improved over time. Methods In 2013, internal medicine residents at a large academic medical center were asked to participate in an on-line survey that assessed their attitudes and experiences with discussing EOL care with terminally-ill patients. These results were compared to data from a similar survey residents in the same program completed in 2006. Results Eighty-three (50%) residents completed the 2013 survey. About half (52%) felt strongly that they were able to have open, honest discussions with patients and families, while 71% felt conflicted about whether CPR was in the patient’s best interest. About half (53%) felt strongly that it was okay for them to tell a patient/family member whether or not CPR was a good idea for them. Compared to 2006 respondents, the 2013 cohort felt they had more lectures about EOL communication, and had watched an attending have an EOL discussion more often. Conclusions Modest improvements were made over time in trainees’ exposure to EOL discussions; however, many residents remain uncomfortable and conflicted with having EOL care discussions with their patients. More effective training approaches in EOL communication are needed to train the next generation of internists. PMID:24418692

  16. Communication About Advance Directives and End-of-Life Care Options Among Internal Medicine Residents.

    Science.gov (United States)

    Rhodes, Ramona L; Tindall, Kate; Xuan, Lei; Paulk, M Elizabeth; Halm, Ethan A

    2015-05-01

    Despite increasing awareness about the importance of discussing end-of-life (EOL) care options with terminally ill patients and families, many physicians remain uncomfortable with these discussions. The objective of the study was to examine perceptions of and comfort with EOL care discussions among a group of internal medicine residents and the extent to which comfort with these discussions has improved over time. In 2013, internal medicine residents at a large academic medical center were asked to participate in an on-line survey that assessed their attitudes and experiences with discussing EOL care with terminally-ill patients. These results were compared to data from a similar survey residents in the same program completed in 2006. Eighty-three (50%) residents completed the 2013 survey. About half (52%) felt strongly that they were able to have open, honest discussions with patients and families, while 71% felt conflicted about whether CPR was in the patient's best interest. About half (53%) felt strongly that it was okay for them to tell a patient/family member whether or not CPR was a good idea for them. Compared to 2006 respondents, the 2013 cohort felt they had more lectures about EOL communication, and had watched an attending have an EOL discussion more often. Modest improvements were made over time in trainees' exposure to EOL discussions; however, many residents remain uncomfortable and conflicted with having EOL care discussions with their patients. More effective training approaches in EOL communication are needed to train the next generation of internists. © The Author(s) 2014.

  17. Acute pain management efficiency improves with point-of-care handheld electronic billing system.

    Science.gov (United States)

    Fahy, Brenda G

    2009-02-01

    Technology advances continue to impact patient care and physician workflow. To enable more efficient performance of billing activities, a point-of-care (POC) handheld computer technology replaced a paper-based system on an acute pain management service. Using a handheld personal digital assistant (PDA) and software from MDeverywhere (MDe, MDeverywhere, Long Island, NY), we performed a 1-yr prospective observational study of an anesthesiology acute pain management service billings and collections. Seventeen anesthesiologists providing billable acute pain services were trained and entered their charges on a PDA. Twelve months of data, just before electronic implementation (pre-elec), were compared to a 12-m period after implementation (post-elec). The total charges were 4883 for 890 patients pre-elec and 5368 for 1128 patients post-elec. With adoption of handheld billing, the charge lag days decreased from 29.3 to 7.0 (P billing using PDAs to replace a paper-based billing system improved the collection rate and decreased the number of charge lag days with a positive return on investment. The handheld PDA billing system provided POC support for physicians during their daily clinical (e.g., patient locations, rounding lists) and billing activities, improving workflow.

  18. Nurse-delivered universal point-of-care testing for HIV in an open-access returning traveller clinic.

    Science.gov (United States)

    Herbert, R; Ashraf, A N; Yates, T A; Spriggs, K; Malinnag, M; Durward-Brown, E; Phillips, D; Mewse, E; Daniel, A; Armstrong, M; Kidd, I M; Waite, J; Wilks, P; Burns, F; Bailey, R; Brown, M

    2012-09-01

    Early diagnosis of HIV infection reduces morbidity and mortality associated with late presentation. Despite UK guidelines, the HIV testing rate has not increased. We have introduced universal HIV screening in an open-access returning traveller clinic. Data were prospectively recorded for all patients attending the open-access returning traveller clinic between August 2008 and December 2010. HIV testing was offered to all patients from May 2009; initially testing with laboratory samples (phase 1) and subsequently a point-of-care test (POCT) (phase 2). A total of 4965 patients attended the clinic; 1342 in phase 0, 792 in phase 1 and 2831 in phase 2. Testing rates for HIV increased significantly from 2% (38 of 1342) in phase 0 to 23.1% (183 of 792) in phase 1 and further increased to 44.5% (1261 of 2831) during phase 2 (P travelling to the Middle East and Europe were less likely to accept an HIV test with POCT. A nurse-delivered universal point-of-care HIV testing service has been successfully introduced and sustained in an acute medical clinic in a low-prevalence country. Caution is required in communicating reactive results in low-prevalence settings where there may be alternative diagnoses or a low population prevalence of HIV infection. © 2012 British HIV Association.

  19. [Regulation of sexual expression in residential aged care facilities: A professional point of view].

    Science.gov (United States)

    Villar, Feliciano; Fabà, Josep; Celdrán, Montserrat; Serrat, Rodrigo

    2014-01-01

    The purpose of this study is to determine the opinion of professionals working in residential aged care facilities on the regulation of sexuality in these settings. Fifty-three professionals from five residential aged care facilities located in the metropolitan area of Barcelona answered several questions regarding the advisability of establishing measures for the regulation of sexuality in RACFs, the elements that could contribute to this, and the aspects that such regulations should consider. Around 50% of the participants recognized the advisability of having some type of measures for sexuality regulation in residential aged care facilities. According to their responses this should be developed taking into account professional opinions, but also the points of view of the residents and their relatives. The most frequently mentioned regulations were those that ensured that any kind of sexually charged situation occurred in a private environment. The development of strategies are suggested to distinguish those people with dementia that are competent to consent to sexual acts from those who are not. The opinion of professionals working in RACFs regarding the advisability of establishing measures for sexuality regulation seems to be considerably divided. Thus, whilst around 50% of them recognize their potential usefulness, the other half consider them unnecessary or even counterproductive for the sexual freedom of residents. Associating regulation with prohibition and sexuality with sexual activity was not uncommon among the responses of the participants. Copyright © 2014 SEGG. Published by Elsevier Espana. All rights reserved.

  20. Acceptability and Feasibility of Integrating Point-of-Care Diagnostic Testing of Sexually Transmitted Infections into a South African Antenatal Care Program for HIV-Infected Pregnant Women

    Directory of Open Access Journals (Sweden)

    E. Morikawa

    2018-01-01

    Full Text Available Background. Chlamydia trachomatis (CT, Neisseria gonorrhoeae (NG, and Trichomonas vaginalis (TV infections may increase the risk of vertical transmission of the human immunodeficiency virus (HIV. In resource-limited settings, symptomatic screening, and syndromic management of sexually transmitted infections (STIs during pregnancy continue to be the standard of care. In the absence of diagnostic testing, asymptomatic infections in pregnant women go untreated. Objective. To describe the acceptability and feasibility of integrating diagnostic STI screening into first antenatal care visits for HIV-infected pregnant women. Methods. HIV-infected pregnant women were recruited during their first antenatal care visit from three antenatal care clinics in Tshwane District, South Africa, between June 2016 and October 2017. Self-collected vaginal swabs were used to screen for CT, NG, and TV with a diagnostic point-of-care (POC nucleic acid amplification test. Those with STIs were provided treatment per South African national guidelines. Results. Of 442 eligible women, 430 (97.3% agreed to participate and were tested. Of those with a positive STI test result (n = 173; 40.2%, 159 (91.9% received same-day results and treatment; 100% of STI-infected women were treated within seven days. Conclusions. Integration of POC diagnostic STI screening into first-visit antenatal care services was feasible and highly acceptable for HIV-infected pregnant women.

  1. Point-of-care Ultrasound Detection of Endophthalmitis

    Directory of Open Access Journals (Sweden)

    James Tucker

    2018-01-01

    Full Text Available History of present illness: A 59-year-old woman presented to the emergency department (ED with right eye pain. She had a history of cataract surgery in the right eye three months prior. The patient was seen at an outside ED eight days prior and reportedly had normal vision, normal eye pressures, with a large corneal ulcer and hypopyon in the anterior chamber. She was given subconjunctival injections of antibiotics and discharged with antibiotic drops. She was seen by a retina specialist the next day and had no evidence of endophthalmitis. On her second ED presentation, she had worsening right eye pain. Workup included normal intraocular pressures bilaterally and visual acuity with only light-perception in the affected eye. An ultrasound of her right eye was performed and is shown in figures 1 and 2. Significant findings: The patient’s ultrasound revealed an attached retina and a complex network of hyperechoic, mobile, membranous material in the posterior segment. Discussion: Endophthalmitis is a bacterial or fungal infection inside the vitreous and/or aqueous humors. The classic presentation is painful vision loss in a patient with recent ophthalmologic surgical intervention, an immunocompromised patient, or a septic patient. The specific bacteria or fungus causing the infection will vary depending on the reason for infection (post-surgical vs sepsis. Ultrasound findings typically include low amplitude mobile echoes, vitreous membranes, and thickening of the retina and choroid.1 Treatment for endophthalmitis includes direct, intraocular antibiotic injections by an ophthalmologist; hence, disposition for these patients would include admission for ophthalmology consultation. If there is a blood source of infection rather than a direct ocular inoculation, IV antibiotics should be initiated. Patients should also receive tetanus vaccination if tetanus status is outdated. In this case, the patient was diagnosed with endophthalmitis of the right eye

  2. Vitamin K Acupuncture Point Injection for Severe Primary Dysmenorrhea: An International Pilot Study

    Science.gov (United States)

    Wang, Li; Zhao, Wenjie; Yu, Jin; Cardini, Francesco; Forcella, Emanuela; Regalia, Anna Laura; Wade, Christine

    2004-01-01

    Context Vitamin K acupuncture point injection, a menstrual pain treatment derived from traditional Chinese medicine, has been a standard treatment in some hospitals in China since the 1980s. Objectives To investigate the effects of vitamin K acupuncture point injection on menstrual pain in young women aged 14 to 25 from different countries and cultural backgrounds who have had unmitigated severe primary dysmenorrhea for 6 months or more Design Prospective, observational, clinical pilot study Settings One site in China (a hospital outpatient clinic in Shanghai) and 2 sites in Italy (a hospital clinic in Milan and a private gynecology practice in Verona) Interventions All subjects were treated with bilateral acupuncture point injection of vitamin K on the first or second day of menstrual pain. Vitamin K3 was used in China and vitamin K4 in Italy. Main Outcome Measures Pain intensity, total duration, and average intensity of menstrual distress, hours in bed, normal daily activity restrictions, and numbers of analgesic tablets taken to relieve pain were recorded before the treatment and for 4 subsequent menstrual cycles. Results Noticeable pain relief was observed 2 minutes after treatment, and subsequent pain reduction occurred at 30 minutes (P vitamin K alleviated acute menstrual pain, and relief extended through the nontreatment follow-up cycles in this uncontrolled pilot study conducted in 2 countries. Further investigation employing controlled experimental designs is warranted. PMID:15775872

  3. 10th International Geostatistics Congress

    CERN Document Server

    Rodrigo-Ilarri, Javier; Rodrigo-Clavero, María; Cassiraga, Eduardo; Vargas-Guzmán, José

    2017-01-01

    This book contains selected contributions presented at the 10th International Geostatistics Congress held in Valencia from 5 to 9 September, 2016. This is a quadrennial congress that serves as the meeting point for any engineer, professional, practitioner or scientist working in geostatistics. The book contains carefully reviewed papers on geostatistical theory and applications in fields such as mining engineering, petroleum engineering, environmental science, hydrology, ecology, and other fields.

  4. Comparison of Patient Costs in Internal Medicine and Anaesthesiology Intensive Care Units in a Tertiary University Hospital.

    Science.gov (United States)

    Kara, İskender; Yıldırım, Fatma; Başak, Dilek Yumuş; Küçük, Hamit; Türkoğlu, Melda; Aygencel, Gülbin; Katı, İsmail; Karabıyık, Lale

    2015-06-01

    The allocation of the Gross Domestic Product (GDP) to health is limited, therefore it has made a need for professional management of health business. Hospital managers as well as employees are required to have sufficient knowledge about the hospital costs. Hospital facilities like intensive care units that require specialization and advanced technology have an important part in costs. For this purpose, cost analysis studies should be done in the general health business and special units separately. In this study we aimed to compare the costs of anaesthesiology and internal medicine intensive care units (ICU) roughly. After approval of this study by Gazi University Faculty of Medicine Ethics Committee, the costs of 855 patients that were hospitalized, examined and treated for at least 24 hours in internal medicine and anaesthesiology ICUs between January 2012-August 2013 (20 months period) were taken and analyzed from chief staff of the Department of Information Technology, Gazi University Hospital. At the end of the study, we observed clear differences between internal medicine and anaesthesiology ICUs arising from transactions and patient characteristics of units. We stated that these differences should be considered by Social Security Institution (SSI) for the reimbursement of the services. Further, we revealed that SSI payments do not meet the intensive care expenditure.

  5. 77 FR 5864 - BluePoint Linux Software Corp., China Bottles Inc., Long-e International, Inc., and Nano...

    Science.gov (United States)

    2012-02-06

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] BluePoint Linux Software Corp., China Bottles Inc., Long-e International, Inc., and Nano Superlattice Technology, Inc.; Order of Suspension of... that there is a lack of current and accurate information concerning the securities of Nano Superlattice...

  6. 2014 President's plenary international psycho-oncology society: moving toward cancer care for the whole patient.

    Science.gov (United States)

    Bultz, Barry D; Travado, Luzia; Jacobsen, Paul B; Turner, Jane; Borras, Josep M; Ullrich, Andreas W H

    2015-12-01

    The International Psycho-oncology Society (IPOS) has just celebrated its 30th anniversary. The growth of psychosocial oncology has been exponential, and this relatively new field is becoming a core service that focuses on prevention, reducing the burden of cancer, and enhancing the quality of life from time of diagnosis, through treatment, survivorship, and palliative care. Looking back over the past 30 years, we see that cancer care globally has evolved to a new and higher standard. Today, 'cancer care for the whole patient' is being accomplished with an evidence-based model that addresses psychosocial needs and integrates psycho-oncology into the treatment and care of patients. The President's Plenary Session in Lisbon, Portugal, highlighted the IPOS Mission of promoting global excellence in psychosocial care of people affected by cancer through our research, public policy, advocacy, and education. The internationally endorsed IPOS Standard of Quality Cancer Care, for example, clearly states the necessity of integrating the psychosocial domain into routine care, and that distress should be measured as the sixth vital sign after temperature, blood pressure, pulse, respiratory rate, and pain. The plenary paper also discussed the global progress being made in Europe, North America, and Australia in providing quality cancer care for the whole patient. Collaborative partnerships between IPOS and organizations such as the European Partnership Action Against Cancer and the World Health Organization are essential in building capacity for the delivery of high-quality psycho-oncology services in the future. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Using decision-analytic modelling to transfer international evidence from health technology assessment to the context of the German health care system

    Directory of Open Access Journals (Sweden)

    Siebert, Uwe

    2005-11-01

    Full Text Available The objective of this Health Technology Assessment (HTA methods report was to examine and to assess decision analysis (DA as a method to transfer and adapt international scientific evidence in HTA to the German health care context. Furthermore, we sought to develop a systematic framework to facilitate the selection, transfer, adaptation, and synthesis of these data in German HTA projects. In this report, we review and summarise the concepts and methods of DA; present potential areas of applications, and provide a basis for the critical assessment of decision-analytic studies. The two main methods of DA, decision trees and Markov models, as well as various approaches to sensitivity analyses are described. Examples of typical situations for the use of DA in scientific evidence transfer are described, and a list of main health care domains and parameters in evidence transfer is presented. Finally, we developed a framework to transfer and apply international evidence to the national health care context. The strengths and limitations of the decision-analytic approach are critically examined. In summary, this HTA report describes different situations, in which decision-analytic models can be useful, and demonstrates the utility of DA in transferring and applying international evidence to the national health care context. We developed a systematic instrument to transfer international evidence to the context of other countries and successfully applied this instrument in two German HTA projects. The use of this instrument is recommended in further HTA projects dealing with the application of international evidence to the German health care context. The use of decision-analytic models to transfer international evidence is endorsed. However, the limitations of DA should be clearly stated discussed transparently in all HTA reports.

  8. Protocol for a randomised controlled implementation trial of point-of-care viral load testing and task shifting: the Simplifying HIV TREAtment and Monitoring (STREAM) study.

    Science.gov (United States)

    Dorward, Jienchi; Garrett, Nigel; Quame-Amaglo, Justice; Samsunder, Natasha; Ngobese, Hope; Ngomane, Noluthando; Moodley, Pravikrishnen; Mlisana, Koleka; Schaafsma, Torin; Donnell, Deborah; Barnabas, Ruanne; Naidoo, Kogieleum; Abdool Karim, Salim; Celum, Connie; Drain, Paul K

    2017-09-27

    Achieving the Joint United Nations Programme on HIV and AIDS 90-90-90 targets requires models of HIV care that expand antiretroviral therapy (ART) coverage without overburdening health systems. Point-of-care (POC) viral load (VL) testing has the potential to efficiently monitor ART treatment, while enrolled nurses may be able to provide safe and cost-effective chronic care for stable patients with HIV. This study aims to demonstrate whether POC VL testing combined with task shifting to enrolled nurses is non-inferior and cost-effective compared with laboratory-based VL monitoring and standard HIV care. The STREAM (Simplifying HIV TREAtment and Monitoring) study is an open-label, non-inferiority, randomised controlled implementation trial. HIV-positive adults, clinically stable at 6 months after ART initiation, will be recruited in a large urban clinic in South Africa. Approximately 396 participants will be randomised 1:1 to receive POC HIV VL monitoring and potential task shifting to enrolled nurses, versus laboratory VL monitoring and standard South African HIV care. Initial clinic follow-up will be 2-monthly in both arms, with VL testing at enrolment, 6 months and 12 months. At 6 months (1 year after ART initiation), stable participants in both arms will qualify for a differentiated care model involving decentralised ART pickup at community-based pharmacies. The primary outcome is retention in care and virological suppression at 12 months from enrolment. Secondary outcomes include time to appropriate entry into the decentralised ART delivery programme, costs per virologically suppressed patient and cost-effectiveness of the intervention compared with standard care. Findings will inform the scale up of VL testing and differentiated care in HIV-endemic resource-limited settings. Ethical approval has been granted by the University of KwaZulu-Natal Biomedical Research Ethics Committee (BFC296/16) and University of Washington Institutional Review Board (STUDY

  9. Relating Child Care during Infancy to Externalizing and Internalizing Behaviors in Toddlerhood: How Specific Features of Child Care Quality Matter Depending on a Child's Gender and Temperament

    Science.gov (United States)

    Lemay, Lise; Bigras, Nathalie; Bouchard, Caroline

    2014-01-01

    This study explored whether the relationships between specific features of child care quality and externalizing and internalizing behaviors in 24-month-old children are moderated by gender and temperament. Questionnaires were used to record children's gender and measure their temperament. Child care quality was observed with the "Échelles…

  10. Free Access to Point of Care Resource Results in Increased Use and Satisfaction by Rural Healthcare Providers

    Directory of Open Access Journals (Sweden)

    Lindsay Alcock

    2016-12-01

    Full Text Available A Review of: Eldredge, J. D., Hall, L. J., McElfresh, K. R., Warner, T. D., Stromberg, T. L., Trost, J. T., & Jelinek, D. A. (2016. Rural providers’ access to online resources: A randomized controlled trial. Journal of the Medical Library Association, 104(1, 33-41. http://dx.doi.org/10.3163/1536-5050.104.1.005 Objective – To determine whether free access to the point of care (PoC resource Dynamed or the electronic book collection AccessMedicine was more useful to rural health care providers in answering clinical questions in terms of usage and satisfaction. Design – Randomized controlled trial. Setting – Rural New Mexico. Subjects – Twenty-eight health care providers (physicians, nurses, physician assistants, and pharmacists with no reported access to PoC resources, (specifically Dynamed and AccessMedicine or electronic textbook collections prior to enrollment.

  11. Achieving Prudent Dementia Care (Palliare: An International Policy and Practice Imperative

    Directory of Open Access Journals (Sweden)

    Debbie Tolson

    2016-12-01

    Full Text Available This paper examines the provision of integrated advanced dementia care within seven European countries and critically reviews the potential contribution of the Prudent Healthcare perspective as a starting point for reform. Progressive efforts to innovate, promote quality and integrate care are tempered with the reality of resource constraints. Some policy makers in Europe and North America have turned their attention to the principles of Prudent Healthcare as a potential mechanism to maximise benefits for patients within available resources. As dementia progresses, living well requires increasing levels of support and care, people living with advanced dementia have complex health and social care needs, are highly dependent on others but are not yet at the terminal end stage of the condition. People with advanced dementia can benefit from a dementia specific palliative approach to care ('Palliare', that helps them to live the best life possible for the months and often years they live with advanced dementia. It is also highly desirable to align policy innovations with integrated palliative care practice models and the education of the dementia workforce to accelerate informed improvements in advanced dementia care. There may be some coherence, at least superficially between Prudent Healthcare and integrated palliative care models such as Palliare. It is argued that for successful implementation, both require practitioners to be equipped with knowledge and skills and be empowered to deliver high quality care often within impoverished care environments. Adoption of the prudent perspective will however require development of a repertoire of approaches to hear the voice or proxy voice of people living with advanced dementia and to commit to the development and implementation of new evidence for advanced dementia practice. Evidence informing this policy debate draws upon contemporary literature and policy and the findings from research activities

  12. The opportunities and challenges of pragmatic point-of-care randomised trials using routinely collected electronic records : evaluations of two exemplar trials

    NARCIS (Netherlands)

    van Staa, Tjeerd-Pieter; Dyson, Lisa; McCann, Gerard; Padmanabhan, Shivani; Belatri, Rabah; Goldacre, Ben; Cassell, Jackie; Pirmohamed, Munir; Torgerson, David; Ronaldson, Sarah; Adamson, Joy; Taweel, Adel; Delaney, Brendan; Mahmood, Samhar; Baracaia, Simona; Round, Thomas; Fox, Robin; Hunter, Tommy; Gulliford, Martin; Smeeth, Liam

    BACKGROUND: Pragmatic trials compare the effects of different decisions in usual clinical practice. OBJECTIVES: To develop and evaluate methods to implement simple pragmatic trials using routinely collected electronic health records (EHRs) and recruiting patients at the point of care; to identify

  13. Review of Commercially Available Microfluidic Materials and Fabricating Techniques for Point of Care Testing

    Directory of Open Access Journals (Sweden)

    Luck EREKU

    2016-07-01

    Full Text Available During the last two decades silicon and MEMs technology had been the mainstay of early microfluidic devices. However, recent times have brought into focus the need for low cost and readily available materials capable of achieving the expected microfluidics physical and chemical requirements. Also what mentioning is the rapid improvement in microfabrication technology over the years, which has significantly aided new and cheaper ways to produce microfluidic Point-Of-Care-Testing devices commercially or for research purposes. This review article discusses the usefulness of a wide range of available materials and their unique properties suitability in microfluidic applications. Likewise, advantages and drawbacks of manufacturing procedures and outputs of different fabrication methods are also brought into focus.

  14. The comparison of exit-site care with normal saline and povidone-iodine in preventing exit-site infection and peritonitis in children on chronic peritoneal dialysis treatment

    Directory of Open Access Journals (Sweden)

    Onder Yavascan

    2011-01-01

    Full Text Available Peritonitis and catheter exit- site infections (ESI are important causes of hospitalization and catheter loss in patients undergoing chronic peritoneal dialysis (CPD. The frequency of infection can be reduced by scrupulous exit- site care with or without topical antiseptics. There are no studies showing any benefit in the use of povidone-iodine or normal saline for care of exit- sites in long- term CPD patients. In this study, we aimed to determine the potential effectiveness of the application of povidone-iodine or normal saline at the catheter exit- site in preventing ESI and peritonitis in children on CPD. A total of 98 patients treated with either povidone-iodine or normal saline were included in this study. Group I (34 patients used povidone-iodine and group II (64 patients simply cleansed the exit- site with normal saline (0.9% NaCl. Dressings were changed 2 to 3 times in a week. The total cumulative follow- up time was 3233 patient- months. ESIs occurred in 10 (29.4% of 34 patients using povidone-iodine and in 10 (15.6% of 64 patients using normal saline. The frequency of ESI was significantly high in group I (povidone-iodine patients. The mean rate of ESI was 1 episode/60.8 patient- months for group I versus 1 episode/144 patient- months for group II (P 0.05. In conclusion, exit- site care with normal saline is an effective strategy in reducing the incidence of ESI in children on CPD. It can thus significantly reduce morbidity, catheter loss, and the need to transfer patients on peritoneal dialysis to hemodialysis.

  15. Point-of-care, portable microfluidic blood analyzer system

    Science.gov (United States)

    Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.

    2012-03-01

    Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.

  16. A brief educational intervention to teach residents shared decision making in the intensive care unit.

    Science.gov (United States)

    Yuen, Jacqueline K; Mehta, Sonal S; Roberts, Jordan E; Cooke, Joseph T; Reid, M Carrington

    2013-05-01

    Effective communication is essential for shared decision making with families of critically ill patients in the intensive care unit (ICU), yet there is limited evidence on effective strategies to teach these skills. The study's objective was to pilot test an educational intervention to teach internal medicine interns skills in discussing goals of care and treatment decisions with families of critically ill patients using the shared decision making framework. The intervention consisted of a PowerPoint online module followed by a four-hour workshop implemented at a retreat for medicine interns training at an urban, academic medical center. Participants (N=33) completed post-intervention questionnaires that included self-assessed skills learned, an open-ended question on the most important learning points from the workshop, and retrospective pre- and post-workshop comfort level with ICU communication skills. Participants rated their satisfaction with the workshop. Twenty-nine interns (88%) completed the questionnaires. Important self-assessed communication skills learned reflect key components of shared decision making, which include assessing the family's understanding of the patient's condition (endorsed by 100%) and obtaining an understanding of the patient/family's perspectives, values, and goals (100%). Interns reported significant improvement in their comfort level with ICU communication skills (pre 3.26, post 3.73 on a five-point scale, p=0.004). Overall satisfaction with the intervention was high (mean 4.45 on a five-point scale). The findings suggest that a brief intervention designed to teach residents communication skills in conducting goals of care and treatment discussions in the ICU is feasible and can improve their comfort level with these conversations.

  17. Impact of point-of-sale tobacco display bans: findings from the International Tobacco Control Four Country Survey

    OpenAIRE

    Li, Lin; Borland, Ron; Fong, Geoffrey T.; Thrasher, James F.; Hammond, David; Cummings, Kenneth M.

    2013-01-01

    This study examined the impact of point-of-sale (POS) tobacco marketing restrictions in Australia and Canada, in relation to the United Kingdom and the United States where there were no such restrictions during the study period (2006–10). The data came from the International Tobacco Control Four Country Survey, a prospective multi-country cohort survey of adult smokers. In jurisdictions where POS display bans were implemented, smokers’ reported exposure to tobacco marketing declined markedly....

  18. Feasibility and clinical utility of the Japanese version of the Abbey pain scale in Japanese aged care.

    Science.gov (United States)

    Takai, Yukari; Yamamoto-Mitani, Noriko; Chiba, Yumi; Kato, Ayako

    2014-06-01

    Active usage of observational pain scales in Japanese aged-care facilities has not been previously described. Therefore, to examine the feasibility and clinical utility of the Abbey Pain Scale-Japanese version (APS-J), this study examined the interrater reliability of the APS-J among a researcher, nurses, and care workers in aged-care facilities in Japan. This study also aimed to obtain nurses' and care workers' opinions on use of the scale. The following data were collected from 88 residents of two aged-care facilities: demographics, Barthel Index, Folstein Mini-Mental Examination (MMSE), 15-item Geriatric Depression Scale (GDS-15), and APS-J for pain. The researchers, nurses, and care workers independently assessed the residents' pain by using the APS-J, and intraclass correlation coefficients (ICC) for interrater reliability and Cronbach alpha for internal consistency were examined. The ICC between researchers and nurses, researchers and care workers, and nurses and care workers were 0.68, 0.74, and 0.76, respectively. Nurses and care workers were invited for focus group interviews to obtain their opinions regarding APS-J use. During these interviews, nurses and care workers stated that the observational points of APS-J subscales were the criteria they normally used to evaluate residents' pain. Several nurses and care workers reported a gap between the estimated pain intensity and APS-J score. Unclear APS-J criteria, difficulties in observing residents, and insufficient practice guidelines were also reported. Our findings indicate that the APS-J has moderate reliability and clinically utility. To facilitate APS-J usage, education and clinical guidelines for pain management may be required for nurses and care workers. Copyright © 2014 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  19. Measurement of cardiac troponin I utilizing a point of care analyzer in healthy alpacas.

    Science.gov (United States)

    Blass, Keith A; Kraus, Marc S; Rishniw, Mark; Mann, Sabine; Mitchell, Lisa M; Divers, Thomas J

    2011-12-01

    Myocardial disease in camelids is poorly characterized. Nutritional (selenium deficiency) and toxic (ionophore toxicity) myocardial disease have been reported in camelids. Diagnosis and management of these and other myocardial diseases might be enhanced by evaluating cardiac troponin I (cTnI) concentrations. No information about cTnI reference intervals in camelids is currently available. (A) To determine cTnI concentrations obtained using a point of care i-STAT(®)1 analyzer (Heska Corporation) in healthy alpacas; (B) to compare alpaca cTnI concentrations between heparinized whole blood and plasma samples and between 2 different storage conditions (4 °C for 24 h or -80 °C for 30 days); (C) to examine assay reproducibility using the i-STAT(®)1. 23 healthy alpacas were evaluated. Blood and plasma samples were analyzed by the i-STAT(®)1 within 1 h of collection. Aliquots of plasma were stored at either 4 °C for 24 h or -80 °C for 30 days, and then analyzed. Assay reproducibility was determined by comparing 2 plasma or whole blood cTnI concentrations measured on the same sample over a 10 min period. Analyzer-specific plasma cTnI concentrations in clinically normal alpacas had a median of blood concentrations showed good agreement. Storage did not affect cTnI concentrations (p > 0.75). Plasma cTnI concentrations had coefficient of repeatability of 0.02 ng/mL. The i-STAT(®)1 can measure cTnI in alpacas on both plasma and whole blood and provides similar values for both samples. Storage at 4 °C for 24 h or -80 °C for 30 days does not affect estimates of plasma cTnI. Evaluation of cTnI might be of value in assessing cardiac disease in this species. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Can the Afinion HbA1c Point-of-Care instrument be an alternative method for the Tosoh G8 in the case of Hb-Tacoma?

    Science.gov (United States)

    Lenters-Westra, Erna; Strunk, Annuska; Campbell, Paul; Slingerland, Robbert J

    2017-02-01

    Hb-variant interference when reporting HbA1c has been an ongoing challenge since HbA1c was introduced to monitor patients with diabetes mellitus. Most Hb-variants show an abnormal chromatogram when cation-exchange HPLC is used for the determination of HbA1c. Unfortunately, the Tosoh G8 generates what appears to be normal chromatogram in the presence of Hb-Tacoma, yielding a falsely high HbA1c value. The primary aim of the study was to investigate if the Afinion HbA1c point-of-care (POC) instrument could be used as an alternative method for the Tosoh G8 when testing for HbA1c in the presence of Hb-Tacoma. Whole blood samples were collected in K 2 EDTA tubes from individuals homozygous for HbA (n = 40) and heterozygous for Hb-Tacoma (n = 20). Samples were then immediately analyzed with the Afinion POC instrument. After analysis, aliquots of each sample were frozen at -80 °C. The frozen samples were shipped on dry ice to the European Reference Laboratory for Glycohemoglobin (ERL) and analyzed with three International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and National Glycohemoglobin Standardization Program (NGSP) Secondary Reference Measurement Procedures (SRMPs). The Premier Hb9210 was used as the reference method. When compared to the reference method, samples with Hb-Tacoma yielded mean relative differences of 31.8% on the Tosoh G8, 21.5% on the Roche Tina-quant Gen. 2 and 16.8% on the Afinion. The Afinion cannot be used as an alternative method for the Tosoh G8 when testing for HbA1c in the presence of Hb-Tacoma.