WorldWideScience

Sample records for point thomson scattering

  1. LIDAR Thomson scattering

    International Nuclear Information System (INIS)

    1991-07-01

    This collection contains 21 papers on the application and development of LIDAR (Light Detection and Ranging) Thomson scattering techniques for the determination of spatially resolved electron temperature and density in magnetic confinement experiments, particularly tokamaks. Refs, figs and tabs

  2. A parallelized Python based Multi-Point Thomson Scattering analysis in NSTX-U

    Science.gov (United States)

    Miller, Jared; Diallo, Ahmed; Leblanc, Benoit

    2014-10-01

    Multi-Point Thomson Scattering (MPTS) is a reliable and accurate method of finding the temperature, density, and pressure of a magnetically confined plasma. Nd:YAG (1064 nm) lasers are fired into the plasma with a frequency of 60 Hz, and the light is Doppler shifted by Thomson scattering. Polychromators on the midplane of the tokamak pick up the light at various radii/scattering angles, and the avalanche photodiode's voltages are added to an MDSplus tree for later analysis. This project ports and optimizes the prior serial IDL MPTS code into a well-documented Python package that runs in parallel. Since there are 30 polychromators in the current NSTX setup (12 more will be added when NSTX-U is completed), using parallelism offers vast savings in performance. NumPy and SciPy further accelerate numerical calculations and matrix operations, Matplotlib and PyQt make an intuitive GUI with plots of the output, and Multiprocessing parallelizes the computationally intensive calculations. The Python package was designed with portability and flexibility in mind so it can be adapted for use in any polychromator-based MPTS system.

  3. The real time multi point Thomson scattering diagnostic at NSTX-U

    Science.gov (United States)

    Laggner, Florian; Kolemen, Egemen; Diallo, Ahmed; Leblanc, Benoit; Rozenblat, Roman; Tchilinguirian, Greg; NSTX-U team Team

    2017-10-01

    This contribution presents the upgrade of the multi point Thomson scattering (MPTS) diagnostic for real time application. As a key diagnostic at NSTX-U, the MPTS diagnostic simultaneously measures the electron density (ne) and electron temperature (Te) profiles of a plasma discharge. Therefore, this powerful diagnostic can directly access the electron pressure of the plasma. Currently, only post-discharge evaluation of the data is available, however, since the plasma pressure is one important drive for instabilities, real time measurements of this quantities would be beneficial for plasma control. In a first step, ten MPTS channels were equipped with real time electronics, which improve the data acquisition rate by five orders of magnitude. The commissioning of the system is ongoing and first benchmarks of the real time evaluation routines against the standard, post-discharge evaluation show promising results: The Te as well as ne profiles of both types of analyses agree within their uncertainties. This work was supported by the US Department of Energy under DE-SC0015878 and DE-SC0015480.

  4. Progress on the HIT--II Multi-Point Thomson Scattering Diagnostic

    Science.gov (United States)

    Hamp, W. T.; Jarboe, T. R.; Smith, R. J.; Nelson, B. A.; Rogers, J. A.; Leblanc, B. P.; Phillips, P. E.

    2002-11-01

    The Helicity Injected Torus (HIT--II) multi-point Thomson scattering diagnostic (MPTS) has been designed and built to determine electron temperature and density at 11 radial positions at one time during the plasma discharge. The system includes collection optics and a Littrow mount spectrometer on loan from Princeton, and a 1 GW laser and multi-anode microchannel plate detector (MCP) from the University of Texas. The MPTS is currently operational at 6 spatial positions, indicating electron temperatures greater than 100 eV in transformer driven plasmas. The remaining 5 spatial positions are overloaded by stray laser light. Light reemerging from the beam dump is the primary suspect for stray light. A new beam dump has been constructed in an effort to reduce the stray light and increase the number of operational channels. A new diffraction grating has been constructed to increase the dispersion of the spectrometer to counteract the excessively broad frequency response of the MCP. Plans for MPTS operation include the characterization of density and temperature evolution across reconnection events in CHI driven plasmas, as well as temperature and density characterizations of optimized CHI and transformer driven plasmas in the HIT--II device.

  5. Multichannel Thomson scattering apparatus

    International Nuclear Information System (INIS)

    Bretz, N.; Dimock, D.; Foote, V.; Johnson, D.; Long, D.; Tolnas, E.

    1977-07-01

    A Thomson scattering apparatus for measuring the electron temperature and density along a 90 cm diameter of the PLT plasma has been built. A wide angle objective images the 3 mm x 900 mm ruby laser beam onto an image dissector which rearranges the 300 : 1 image to 20 : 1 forming the input slit of a spectrometer. The stigmatic spectrometer provides 20 wavelength elements of approximately 70 A each. A micro-channel-plate image intensifier optically coupled to a cooled SIT tube provides detection with single frame linearity and 1000 : 1 dynamic range. Spatial profiles of N/sub e/ and T/sub e/ in the range 10 13 - 10 14 cm -3 and 0.05 - 3 keV have an accuracy of 30 √10 13 /N/sub e/ (cm -3 ) percent per 1.2 cm element

  6. The Thomson scattering system at DANTE

    International Nuclear Information System (INIS)

    Gadeberg, M.

    1983-08-01

    The construction and operation of the 90 deg Thomson Scattering diagnostic at DANTE is described. The system is based on a double-pulse ruby laser and a three channel spectrometer. Two single point measurements can be made during each plasma discharge. (Auth.)

  7. Equipment of Thomson scattering measurement on DIVA plasma

    International Nuclear Information System (INIS)

    Yamauchi, Toshihiko; Kumagai, Katsuaki; Funahashi, Akimasa; Matoba, Thoru; Sengoku, Seio

    1980-02-01

    Equipment of Thomson scattering measurement using ruby-laser light is explained. DIVA device was shut down in September 1979; it gave numerous fruitful experimental results during its five years operation. We measured the profiles of electron temperature and density with the Thomson scattering equipment, which played an important role in research of the energy confinement and heating characteristics. In Thomson scattering measurements on DIVA, studies and improvements were made for reduction of stray light, increase of measuring points and data processing. The profile of electron temperature and density were thus measured successful. In this report is given an over-all view of the Thomson scattering equipment together with the above improvements. As two representative examples, the measured results of electron temperature profiles on DIVA plasma under divertor operation and low-q discharge respectively are described. (author)

  8. Operation of the NSTX Thomson Scattering System

    International Nuclear Information System (INIS)

    LeBlanc, B.P.; Bell, R.E.; Johnson, D.W.; Hoffman, D.E.; Long, D.C.; Palladino, R.W.

    2002-01-01

    The NSTX multi-point Thomson scattering system has been in operation for nearly two years and provides routine Te(R,t) and ne(R,t) measurements. The laser beams from two 30-Hz Nd:YAG lasers are imaged by a spherical mirror onto 36 fiber-optics bundles. In the present configuration, the output ends of 20 of these bundles are instrumented with filter polychromators and avalanche photodiode detectors. In this paper, we discuss the laser implementation and the installed collection optics. We follow with examples of raw and analyzed data. We close with some comments about calibration

  9. Theory of Thomson scattering in inhomogeneous media.

    Science.gov (United States)

    Kozlowski, P M; Crowley, B J B; Gericke, D O; Regan, S P; Gregori, G

    2016-04-12

    Thomson scattering of laser light is one of the most fundamental diagnostics of plasma density, temperature and magnetic fields. It relies on the assumption that the properties in the probed volume are homogeneous and constant during the probing time. On the other hand, laboratory plasmas are seldom uniform and homogeneous on the temporal and spatial dimensions over which data is collected. This is particularly true for laser-produced high-energy-density matter, which often exhibits steep gradients in temperature, density and pressure, on a scale determined by the laser focus. Here, we discuss the modification of the cross section for Thomson scattering in fully-ionized media exhibiting steep spatial inhomogeneities and/or fast temporal fluctuations. We show that the predicted Thomson scattering spectra are greatly altered compared to the uniform case, and may lead to violations of detailed balance. Therefore, careful interpretation of the spectra is necessary for spatially or temporally inhomogeneous systems.

  10. Recent improvements in Thomson scattering data analysis

    International Nuclear Information System (INIS)

    Tillack, M.S.; Lazarus, E.A.

    1980-04-01

    A new profile analysis package for use with the Thomson scattering data on ISX-B has recently been implemented. The primary feature of this package is a weighted least squares fitting of temperature and density data to generate a representative curve, as opposed to the previous hand-fitting technique. The changes will automate the manner in which data are transmitted and manipulated, without affecting the calculational techniques previously used. The computer programs have also been used to estimate the sensitivity of various plasma quantities to the accuracy of the Thomson scattering data

  11. Progress in development of the advanced Thomson scattering diagnostics

    International Nuclear Information System (INIS)

    Hatae, T; Naito, O; Howard, J; Ebizuka, N; Yoshida, H; Nakatsuka, M; Fujita, H; Kajita, S; Narihara, K; Yamada, I; Funaba, H; Hirano, Y; Koguchi, H

    2010-01-01

    We have been studied the advanced Thomson scattering diagnostics from viewpoints of new concepts, laser technology and spectrum analysis. This paper summarizes results of development on technologies for advanced Thomson scattering diagnostics.

  12. Design and development of the large helical device TV Thomson scattering

    International Nuclear Information System (INIS)

    Yamada, I.; Narihara, K.; Funaba, H.; Hayashi, H.

    2004-01-01

    We have developed a television (TV) Thomson scattering and installed it on the large helical device (LHD). The LHD TV Thomson scattering consists of a yttrium-aluminum-garnet (YAG) laser, beam transport system, scattered light collection optics, spectrometer, intensified charge coupled device camera, and data acquisition system. The spatial and temporal resolutions are about 7 mm and a few seconds, respectively. The temporal resolution of the LHD TV Thomson scattering is not good, but will be enough for long-time, steady-state discharge experiments in LHD. In the initial experiments, we measured electron temperature profiles of LHD plasmas at five spatial points. It has been found that the electron temperatures measured by the LHD TV Thomson scattering reasonably agree with those obtained by the LHD YAG Thomson scattering. We will report the details of the LHD TV Thomson scattering system with some experimental data

  13. The ITER Thomson scattering core LIDAR diagnostic

    NARCIS (Netherlands)

    Naylor, G.A.; Scannell, R.; Beurskens, M.; Walsh, M.J.; Pastor, I.; Donné, A.J.H.; Snijders, B.; Biel, W.; Meszaros, B.; Giudicotti, L.; Pasqualotto, R.; Marot, L.

    2012-01-01

    The central electron temperature and density of the ITER plasma may be determined by Thomson scattering. A LIDAR topology is proposed in order to minimize the port access required of the ITER vacuum vessel. By using a LIDAR technique, a profile of the electron temperature and density can be

  14. ITER Fast Ion Collective Thomson Scattering

    DEFF Research Database (Denmark)

    Bindslev, Henrik; Larsen, Axel Wright; Meo, Fernando

    2005-01-01

    The EFDA Contract 04-1213 with Risø National Laboratory concerning a detailed integrated design of a Fast Ion Collective Thomson Scattering (CTS) diagnostic for ITER was signed on 31 December 2004. In 2003 the Risø CTS group finished a feasibility study and a conceptual design of an ITER Fast Ion...... Collective Thomson Scattering System (Contract 01.654) [1, 2]. The purpose of the CTS diagnostic is to measure the distribution function of fast ions in the plasma. The feasibility study demonstrated that the only system that can fully meet the ITER measurement requirements for confined fusion alphas is a 60...... GHz system. The study showed that with two powerful microwave sources of this frequency (gyrotron) and two antenna systems, one on the low field side (LFS) and one on the high field side (HFS), it should be possible to resolve the distribution function of fast ions both for perpendicular and parallel...

  15. LIDAR Thomson scattering diagnostic on JET (invited)

    International Nuclear Information System (INIS)

    Salzmann, H.; Bundgaard, J.; Gadd, A.

    1988-01-01

    By combining the time-of-flight or LIDAR principle with a Thomson backscatter diagnostic, spatial profiles of the electron temperature and density are measured in a magnetically confined fusion plasma. This technique was realized for the first time on the JET tokamak. A ruby laser (3-J pulse energy, 300-ps pulse duration, 0.5-Hz repetition rate) together with a 700-MHz bandwidth detection and registration system yields a spatial resolution of about 12 cm. A spectrometer with six channels in the wavelength range 400--800 nm gives a dynamic range of the temperature measurements of 0.3--20 keV. The stray light problem in the backscatter geometry is overcome by spectral discrimination and gating of the photomultipliers. A ruby filter in the spectral channel containing the laser wavelength allows calibration of the vignetting along the line of sight by means of Raman scattering, enabling the measurement of density profiles. The low level of background signal due to the short integration time for a single spatial point yields low statistical errors (ΔT/sub e/ /T/sub e/ ≅6%, Δn/sub e/ /n/sub e/ ≅4% at T/sub e/ = 6 keV, n/sub e/ = 3 x 10/sup 19/ m/sup -3/ ). Goodness-of-fit tests indicate that the systematic errors are within the same limits. The system is described and examples of measurements are given

  16. Thomson scattering on the PRETEXT Tokamak

    International Nuclear Information System (INIS)

    McCool, S.C.

    1982-03-01

    Ruby laser Thomson scattering was performed on the PRETEXT tokamak. A 10 Joule Q-switched laser and a 1 meter 10 channel polychromator were used to diagnose the electron temperature and density profiles in the PRETEXT plasma. These parameters were measured as a function of time and radial position on a shot to shot basis. The density measurement was calibrated by Rayleigh and Raman scattering and by comparison with data from a 4 mm microwave interferometer. Electron densities ranging from 1 x 10 12 cm -3 to 2 x 10 13 cm -3 and temperatures ranging from 3 eV to 400 eV were observed. Detailed measurements were made throughout the 40 ms discharge with particular emphasis on the current rise phase. The Thomson scattering data was used as input to a one dimensional magnetic diffusion code. This code modelled the evolution of the current density and safety factor profiles. The results of this analysis were compared with existing theories of tokamak current penetration. The growth of resitive MHD tearing modes was proposed as a likely explanation for the anomalously rapid current penetration observed in PRETEXT

  17. Thomson scattering in strong external fields

    Science.gov (United States)

    Varró, S.; Ehlotzky, F.

    1992-09-01

    In the present paper we shall investigate relativistic Thomson scattering in two external fields. A free classical electron will be embedded in a strong, constant and homogeneous magnetic field and in a powerful electromagnetic field. Both fields will be considered in the Redmond configuration, in which case the electromagnetic wave is circularly polarized and propagates in the direction of the homogeneous magnetic field. The electron will be allowed to have arbitrary initial conditions and the electromagnetic wave will be switched on either suddenly or adiabatically. We shall present the exact solution of the Lorentz equation of motion in the above external field configuration and we shall evaluate the spectrum and cross sections of the scattered radiation. In particular, we shall consider scattering close to resonance and we shall compare our results with the findings of earlier work.

  18. Thomson scattering of polarized photons in an intense laser beam

    Energy Technology Data Exchange (ETDEWEB)

    Byung Yunn

    2006-02-21

    We present a theoretical analysis of the Thomson scattering of linearly and circularly polarized photons from a pulsed laser by electrons. The analytical expression for the photon distribution functions presented in this paper should be useful to designers of Thomson scattering experiments.

  19. Streaked Thomson Scattering on Laboratory Plasma Jets

    Science.gov (United States)

    Banasek, Jacob; Byvank, Tom; Rocco, Sophia; Kusse, Bruce; Hammer, David

    2017-10-01

    Streaked Thomson scattering measurements have been performed on plasma jets created from a 15 μm thick radial Al or Ti foil load on COBRA, a 1 MA pulsed power machine. The goal was to measure the electron temperatures inside the center of the plasma jet created by the radial foil. The laser used for these measurements had a maximum energy of 10 J at 526.5 nm in a 3 ns duration pulse. Early experiments showed using the full energy significantly heats the 5 ×1018 cm-3 jet by inverse bremsstrahlung radiation. Here we used a streak camera to record the scattered spectrum and measure the evolving electron temperature of this laser heated jet. Analysis of the streak camera image showed that the electron temperature of the Al jet was increased from about 25 eV to 80-100 eV within about 2 ns. The Ti jets showed even stronger interaction with the laser, being heated to over 150 eV, and showed some heating even when only 1 J of laser energy was used. Also, the ion-acoustic peaks in the scattered spectrum from the Ti jets were significantly narrower than those from Al jets. Initial results will also be presented with scattered spectra taken at two different times within a single experiment by splitting the probe beam. This research is supported by the NNSA Stewardship Sciences Academic Programs under DOE Cooperative Agreement DE-NA0001836.

  20. Digital filter polychromator for Thomson scattering applications

    Science.gov (United States)

    Solokha, V.; Kurskiev, G.; Mukhin, E.; Tolstyakov, S.; Babinov, N.; Bazhenov, A.; Bukreev, I.; Dmitriev, A.; Kochergin, M.; Koval, A.; Litvinov, A.; Masyukevich, S.; Razdobarin, A.; Samsonov, D.; Semenov, V.; Solovey, V.; Chernakov, P.; Chernakov, Al; Chernakov, An

    2018-02-01

    Incoherent Thomson scattering diagnostics (TS) is a proven technique capable of reliable and robust instantaneous measurement of electron temperature (T e) and density (n e) local values in wide area of plasma physics experiments: from hall-effect thrusters to tokamaks and stellarators. The TS cross section is very low (˜ 6.7 × 10-30 m2), and the corresponding TS signals, measured in fusion experiments, are usually of ˜10-15 of incident power. This paper represents 6 (7) channel filter polychromator equipped with avalanche photodiodes and low-noise preamplifiers. The incorporated ADC system (5 GS/s, 12 bit) provides digital optical output preventing acquisition system from electromagnetic interferences. The calibration techniques and T e, n e with corresponding errors measured in Globus-M plasma are given for the digital polychromator test-bench.

  1. Thomson Scattering on NSTX-U

    Science.gov (United States)

    Leblanc, Benoit; Diallo, Ahmed

    2016-10-01

    The MPTS Thomson scattering diagnostic has been supporting NSTX-U since its start of operation in August 2015. At the time of this writing more than 1000 plasmas have been documented. While most MPTS elements from ``NSTX'' were reutilized, significant changes were necessitated: The laser-beam path was re-aimed in order to accommodate for the larger center-stack diameter of NSTX-U. The presence of a new neutral beam box required the introduction of mirror optics in order to dump the laser beams away from the measurement region. The FY2016 run marks the start of operation of a previously installed upgrade to 42 channels. Details of the new MPTS configuration will be given and experimental results will be presented. Future plans will also be discussed. This work was funded by DOE contract DE-AC02-09CH11466.

  2. A compact multichannel spectrometer for Thomson scattering.

    Science.gov (United States)

    Schoenbeck, N L; Schlossberg, D J; Dowd, A S; Fonck, R J; Winz, G R

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T(e) VPH grating and measurements T(e) > 100 eV by a 2072 l∕mm VPH grating. The spectrometer uses a fast-gated (~2 ns) ICCD camera for detection. A Gen III image intensifier provides ~45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  3. A compact multichannel spectrometer for Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R. [Department of Engineering Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States)

    2012-10-15

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  4. 154 GHz collective Thomson scattering in LHD

    Science.gov (United States)

    Tanaka, K.; Nishiura, M.; Kubo, S.; Shimozuma, T.; Saito, T.; Moseev, D.; Abramovic, I.

    2018-01-01

    Collective Thomson scattering (CTS) was developed by using a 154 GHz gyrotron, and the first data has been obtained. Already, 77 GHz CTS has worked successfully. However, in order to access higher density region, 154 GHz option enhances the usability that reduces the refraction effect, which deteriorates in the local measurements. The system in the down converted frequency was almost identical to the system for 77 GHz. Probing beam, a notch filter, a mixer, and a local oscillator in the receiver system for 77 GHz option were replaced to those for the 154 GHz option. 154 GHz gyrotron was originally prepared for the second harmonic electron cyclotron heating (ECRH) at 2.75 T. However, scattering signal was masked by the second harmonic electron cyclotron emission (ECE) at 2.75 T. Therefore, 154 GHz CTS was operated at 1.375 T with fourth harmonic ECE, and an acceptable signal to noise ratio was obtained. There is a signature of fast ion components with neutral beam (NB) injection. In addition, the CTS spectrum became broader in hydrogen discharge than in deuterium discharge, as the theoretical CTS spectrum expects. This observation indicates a possibility to identify ion species ratio by the 154 GHz CTS diagnostic.

  5. Improvements to the MST Thomson Scattering Diagnostic

    Science.gov (United States)

    Adams, D. T.; Borchardt, M. T.; den Hartog, D. J.; Holly, D. J.; Kile, T.; Kubala, S. Z.; Jacobson, C. M.; Thomas, M. A.; Wallace, J. P.; Young, W. C.; MST Thomson Scattering Team

    2017-10-01

    Multiple upgrades to the MST Thomson Scattering diagnostic have been implemented to expand capabilities of the system. In the past, stray laser light prevented electron density measurements everywhere and temperature measurements for -z/a >0.75. To mitigate stray light, a new laser beamline is being commissioned that includes a longer entrance flight tube, close-fitting apertures, and baffles. A polarizer has been added to the collection optics to further reduce stray light. An absolute density calibration using Rayleigh scattering in argon will be performed. An insertable integrating sphere will provide a full-system spectral calibration as well as maps optical fibers to machine coordinates. Reduced transmission of the collection optics due to coatings from plasma-surface interactions is regularly monitored to inform timely replacements of the first lens. Long-wavelength filters have been installed to better characterize non-Maxwellian electron distribution features. Previous work has identified residual photons not described by a Maxwellian distribution during m =0 magnetic bursts. Further effort to characterize the distribution function will be described. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences program under Award No. DE-FC02-05ER54814.

  6. Thomson scattering on ELMO Bumpy Torus

    International Nuclear Information System (INIS)

    Cobble, J.A.

    1985-04-01

    Below 10 12 cm -3 density, a Thomson scattering experiment is an exacting task. Aside from the low signal level, the core plasma in this instance is bathed in high-energy x rays, surrounded by a glowing molecular surface plasma, and heated steady state by microwaves. This means that the noise level from radiation is high and the environment is extremely harsh-so harsh that much effort is required to overcome system damage. In spite of this, the ELMO Bumpy Torus (EBT) system has proven itself capable of providing reliable n/sub e/ and T/sub e/ measurements at densities as low as 2 x 10 11 cm -3 . Radial scans across 20 cm of the plasma diameter have been obtained on a routine basis, and the resulting information has been a great help in understanding confinement in the EBT plasma. The bulk electron properties are revealed as flat profiles of n/sub e/ and T/sub e/, with density ranging from 0.5 to 2.0 x 10 12 cm -3 and temperature decreasing from 100 to 20 eV as pressure in the discharge is increased at constant power. Evidence is presented for a suprathermal tail, which amounts to about 10% of the electron distribution at low pressures. The validity of this conclusion is supported by two independent sensitivity calibrations

  7. On some Challenges of Thomson Scattering Measurement in NSTX

    Science.gov (United States)

    Leblanc, Benoit

    2008-11-01

    The large field of view of the Multi-Point Thomson Scattering (MPTS) diagnostic, on the horizontal midplane of the NTSX device, makes the installation of a viewing dump unpractical. Hence one challenge that sometimes occurs during measurement is the presence of high background radiation, which can precludes normal operation of the diagnostic, particularly since the inception of lithium evaporation. A palliative measure has been the installation of polarizer into the viewing optics, which successfully increased the detection dynamic range in presence of high background radiation. Nevertheless cases still occur when detection saturation is present. Some background radiation sources have been identified to be plasma-wall interaction and metallic impurity accumulation. Thomson scattering analysis with a reduced number of spectral channels is being considered as a means to deal with high background-light plasmas. Another challenge recently appeared in the form of significant window coating, observed in 2007 and 2008. An in-situ illumination apparatus has been installed to monitor the transmission during the 2008 run. Details and discussions will be presented along with the effects on the Te and ne measurements. This work is supported by United States DOE contract DE-AC02- 76CH03073.

  8. Research of Fast DAQ system in KSTAR Thomson scattering diagnostic

    Science.gov (United States)

    Lee, J. H.; Kim, H. J.; Yamada, I.; Funaba, H.; Kim, Y. G.; Kim, D. Y.

    2017-12-01

    The Thomson scattering diagnostic is one of the most important diagnostic systems in fusion plasma research. It provides reliable electron temperature and density profiles in magnetically confined plasma. A Q-switched Nd:YAG Thomson system was installed several years ago in KSTAR tokamak to measure the electron temperature and density profiles. For the KSTAR Thomson scattering system, a Charge-to-Digital Conversion (QDC) type data acquisition system was used to measure a pulse type Thomson signal. Recently, however, an error was found during the Te, ne calculation, because the QDC system had integrated the pulse Thomson signal that included a signal similar to stray light. To overcome such errors, we introduce a fast data acquisition (F-DAQ) system. To test this, we use CAEN V1742 5 GS/s, a Versa Module Eurocard Bus (VMEbus) type 12-bit switched capacitor digitizer with 32 channels. In this experiment, we compare the calculated Te results of Thomson scattering data measured simultaneously using QDC and F-DAQ. In the F-DAQ system, the shape of the pulse was restored by fitting.

  9. Analysis method for Thomson scattering diagnostics in GAMMA 10/PDX

    Science.gov (United States)

    Ohta, K.; Yoshikawa, M.; Yasuhara, R.; Chikatsu, M.; Shima, Y.; Kohagura, J.; Sakamoto, M.; Nakasima, Y.; Imai, T.; Ichimura, M.; Yamada, I.; Funaba, H.; Minami, T.

    2016-11-01

    We have developed an analysis method to improve the accuracies of electron temperature measurement by employing a fitting technique for the raw Thomson scattering (TS) signals. Least square fitting of the raw TS signals enabled reduction of the error in the electron temperature measurement. We applied the analysis method to a multi-pass (MP) TS system. Because the interval between the MPTS signals is very short, it is difficult to separately analyze each Thomson scattering signal intensity by using the raw signals. We used the fitting method to obtain the original TS scattering signals from the measured raw MPTS signals to obtain the electron temperatures in each pass.

  10. Experiment of laser thomson scattering at HL-1 tokamak device

    International Nuclear Information System (INIS)

    Zuo Henian; Chen Jiafu; Yan Derong; Liu Aiping; Shi Peilan; Wang Wei; Liu Xiaomei

    1989-05-01

    The structure and performance of the Ruby Laser Thomson Scattering apparatus for HL-1 tokamak device is described. The method of acquisition and calibration of multichannel scattered signals are presented. Examples of measured electron temperature T. with experimental error are given

  11. Molecular origin of background light in Thomson scattering measurements

    International Nuclear Information System (INIS)

    McNeill, D.H.

    1986-06-01

    The plasma background light in Thomson scattering measurements is often far higher than expected for a pure hydrogen plasma. The spectral distribution of light from three plasmas (duration: 1 ms to steady state; electron density: below 10 12 to over 10 14 cm -3 ; temperature: below 20 to over 1000 eV) and signal-to-noise and intensity data from the Thomson scattering systems used on them are compared with analytic estimates to show that in two of these plasmas molecular light dominates the spectrum, while in the other, molecular light is present, but bremsstrahlung is usually more intense. Knowledge of the mechanism for background light can aid in designing detection systems for Thomson scattering and provide information on the neutral species composition and effective charge of the plasma

  12. Applications of phase conjugate mirror to Thomson scattering diagnostics (invited)

    International Nuclear Information System (INIS)

    Hatae, T.; Naito, O.; Nakatsuka, M.; Yoshida, H.

    2006-01-01

    A high performance phase conjugate mirror based on stimulated Brillouin scattering (SBS-PCM) has been applied to the Thomson scattering system in the JT-60U tokamak for the first time in order to improve the measurement performance. A SBS-PCM realized a high reflectivity of 95% at a high input power of 145 W (2.9 J, 50 Hz). Using the SBS-PCM, two methods have been developed to increase the intensity of scattered light. For the first method, we have developed a new optical design to provide a double-pass scattering method with the SBS-PCM. A laser beam passing through the plasma is reflected by the SBS-PCM. The reflected beam passes the plasma again along the same path by means of the phase conjugation of the optically nonlinear stimulated Brillouin scattering process. The double-pass Thomson scattering method using the SBS-PCM has demonstrated an increase of the scattered light by a factor of 1.6 compared with the single-pass scattering method in JT-60U. A multipass Thomson scattering method in which the laser beam can be confined between a couple of SBS-PCMs is also proposed. It is estimated that the multipass scattering method generates the scattered light more than several times as large as that of the single-pass scattering method. For the second method, a high-average-power yttrium aluminum garnet (Nd:YAG) laser system has been developed using the SBS-PCM. The SBS-PCM effectively compensated thermal degradation at two amplifier lines, and the average power was increased by a factor of >8 from 45 W (1.5 J, 30 Hz) to 373 W (7.46 J, 50 Hz). A Nd:YAG laser (5 J, 100 Hz) for the edge Thomson scattering in International Thermonuclear Experimental Reactor (ITER) has been designed based on the result

  13. Thomson Scattering Density Calibration by Rayleigh and Rotational Raman Scattering on NSTX

    Energy Technology Data Exchange (ETDEWEB)

    B.P. LeBlanc

    2008-07-16

    The multi-point Thomson scattering (MPTS) diagnostic measures the profiles of the electron temperature Te(R) and density ne(R) on the horizontal midplane of NSTX. Normal operation makes use of Rayleigh scattering in nitrogen or argon to derive the density profile. While the Rayleigh scattering ne(R) calibration has been validated by comparison with other density measurements and through its correlation with plasma phenomena, it does require dedicated detectors at the laser wavelength in this filter polychromator based diagnostic. The presence of dust and/or stray laser light precludes routine use of these dedicated spectral channels for Thomson scattering measurement. Hence it is of interest to investigate the use of Raman scattering in nitrogen for the purpose of density calibration, since it could free up detection equipment, which could then be used for the instrumentation of additional radial channels. In this paper the viewing optics "geometrical factor" profiles obtained from Rayleigh and Raman scattering are compared. While both techniques agree nominally, residual effects on the order of 10% remain and will be discussed.

  14. Gated integrator PXI-DAQ system for Thomson scattering diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Kiran, E-mail: kkpatel@ipr.res.in; Pillai, Vishal; Singh, Neha; Thomas, Jinto; Kumar, Ajai

    2017-06-15

    Gated Integrator (GI) PXI based data acquisition (DAQ) system has been designed and developed for the ease of acquiring fast Thomson Scattered signals (∼50 ns pulse width). The DAQ system consists of in-house designed and developed GI modules and PXI-1405 chassis with several PXI-DAQ modules. The performance of the developed system has been validated during the SST-1 campaigns. The dynamic range of the GI module depends on the integrating capacitor (C{sub i}) and the modules have been calibrated using 12 pF and 27 pF integrating capacitors. The developed GI module based data acquisition system consists of sixty four channels for simultaneous sampling using eight PXI based digitization modules having eight channels per module. The error estimation and functional tests of this unit are carried out using standard source and also with the fast detectors used for Thomson scattering diagnostics. User friendly Graphical User Interface (GUI) has been developed using LabVIEW on Windows platform to control and acquire the Thomson scattering signal. A robust, easy to operate and maintain with low power consumption, having higher dynamic range with very good sensitivity and cost effective DAQ system is developed and tested for the SST-1 Thomson scattering diagnostics.

  15. Collective Thomson scattering capabilities to diagnose fusion plasmas

    DEFF Research Database (Denmark)

    Korsholm, Søren Bang; Bindslev, Henrik; Furtula, Vedran

    2010-01-01

    Collective Thomson scattering (CTS) is a versatile technique for diagnosing fusion plasmas. In particular, experiments on diagnosing the ion temperature and fast ion velocity distribution have been executed on a number of fusion devices. In this article the main aim is to describe the technique, ...

  16. First 50 pps Thomson scattering diagnostics in a tokamak

    International Nuclear Information System (INIS)

    Roehr, H.; Schramm, G.; Steuer, K.H.; Hirsch, K.; Salzmann, H.

    1981-12-01

    Electron temperature and density measurements by Thomson scattering were performed for the first time for the whole duration of a tokamak discharge. A 50 pps Nd:YAG laser at 1.06 μm was used in ASDEX in combination with Si avalanche photodiode detectors. Density calibration was done by rotational anti-Stokes Raman scattering from hydrogen. The system is used for measurements at electron densities of as low as 2 x 10 12 cm -3 . (orig.)

  17. The LIDAR Thomson Scattering Diagnostic on JET

    DEFF Research Database (Denmark)

    Salzmann, H.; Bundgaard, J.; Gadd, A.

    1988-01-01

    By combining the time‐of‐flight or LIDAR principle with a Thomson backscatter diagnostic, spatial profiles of the electron temperature and density are measured in a magnetically confined fusion plasma. This technique was realized for the first time on the JET tokamak. A ruby laser (3‐J pulse energy......, 300‐ps pulse duration, 0.5‐Hz repetition rate) together with a 700‐MHz bandwidth detection and registration system yields a spatial resolution of about 12 cm. A spectrometer with six channels in the wavelength range 400–800 nm gives a dynamic range of the temperature measurements of 0.3–20 ke...

  18. Double-confocal resonator for X-ray generation via intracavity Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Xie, M. [Lawrence Berkeley Lab., CA (United States)

    1995-12-31

    There has been a growing interest in developing compact X-ray sources through Thomson scattering of a laser beam by a relativistic electron beam. For higher X-ray flux it is desirable to have the scattering to occur inside an optical resonator where the laser power is higher. In this paper I propose a double-confocal resonator design optimized for head-on Thomson scattering inside an FEL oscillator and analyze its performance taking into account the diffraction and FEL gain. A double confocal resonator is equivalent to two confocal resonators in series. Such a resonator has several advantages: it couples electron beam through and X-ray out of the cavity with holes on cavity mirrors, thus allowing the system to be compact; it supports the FEL mode with minimal diffraction loss through the holes; it provides a laser focus in the forward direction for a better mode overlap with the electron beam; and it provides a focus at the same location in the backward direction for higher Thomson scattering efficiency; in addition, the mode size at the focal point and hence the Rayleigh range can be adjusted simply through intracavity apertures; furthermore, it gives a large mode size at the mirrors to reduce power loading. Simulations as well as analytical results will be presented. Also other configurations of intracavity Thomson scattering where the double-confocal resonator could be useful will be discussed.

  19. Control and acquisition for MAST Thomson scattering diagnostics

    International Nuclear Information System (INIS)

    Shibaev, S.; Naylor, G.; Scannell, R.; McArdle, G.; O'Gorman, T.; Walsh, M.J.

    2010-01-01

    The MAST (mega-amp spherical tokamak) Thomson scattering (TS) diagnostics have been radically upgraded and expanded. Eight 30 Hz 1.6 J Nd:YAG lasers have been combined to produce a sampling rate of 240 Hz. The scattered signals are acquired by two spectrometer systems: core and edge. The core system has been built anew: collection optics, polychromators, digitizers, and control computers. It allows measurement of electron temperature and density at 130 spatial points with ∼10 mm resolution across the plasma. The Nd:YAG scattered light signals are registered in 650 channels as polychromator outputs; each channel is registered on two ADCs: at 1 GHz rate in a short interval around each laser pulse and at 100 kHz for background data. The fast ADCs are combined in 26 data acquisition units. Each unit is assembled in a 6 U PXI chassis with embedded controller and six 4-channel 1 GHz ADC cards. Some chassis contain a 96-channel slow ADC card with Ethernet control. The Ruby TS has been rebuilt with a new spectrometer and CCD camera to provide higher spatial resolution - 512 points; the laser has been modified to add double pulse capability. A new control and acquisition system has been developed; it has modular design allowing flexibility and seamless expansion. The system supports event-triggered and real-time operation (will be added in a later stage). A smart trigger device has been developed for TS timing and synchronisation. It provides complex pulse sequences for laser firing with resynchronisation on a number of digital and analogue inputs including plasma events. This device also triggers TS acquisition. The system is integrated by a TS master process running on the dedicated computer; it is represented as a standard MAST data acquisition unit. The Ruby TS is also implemented as a standard MAST unit linked with the Nd:YAG TS by MAST system services.

  20. Accurate calculation of high harmonics generated by relativistic Thomson scattering

    International Nuclear Information System (INIS)

    Popa, Alexandru

    2008-01-01

    The recent emergence of the field of ultraintense laser pulses, corresponding to beam intensities higher than 10 18 W cm -2 , brings about the problem of the high harmonic generation (HHG) by the relativistic Thomson scattering of the electromagnetic radiation by free electrons. Starting from the equations of the relativistic motion of the electron in the electromagnetic field, we give an exact solution of this problem. Taking into account the Lienard-Wiechert equations, we obtain a periodic scattered electromagnetic field. Without loss of generality, the solution is strongly simplified by observing that the electromagnetic field is always normal to the direction electron-detector. The Fourier series expansion of this field leads to accurate expressions of the high harmonics generated by the Thomson scattering. Our calculations lead to a discrete HHG spectrum, whose shape and angular distribution are in agreement with the experimental data from the literature. Since no approximations were made, our approach is also valid in the ultrarelativistic regime, corresponding to intensities higher than 10 23 W cm -2 , where it predicts a strong increase of the HHG intensities and of the order of harmonics. In this domain, the nonlinear Thomson scattering could be an efficient source of hard x-rays

  1. Upgraded divertor Thomson scattering system on DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Glass, F., E-mail: glassf@fusion.gat.com; Carlstrom, T. N.; Du, D.; Taussig, D. A.; Boivin, R. L. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); McLean, A. G. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94550 (United States)

    2016-11-15

    A design to extend the unique divertor Thomson scattering system on DIII-D to allow measurements of electron temperature and density in high triangularity plasmas is presented. Access to this region is selectable on a shot-by-shot basis by redirecting the laser beam of the existing divertor Thomson system inboard — beneath the lower floor using a moveable, high-damage threshold, in-vacuum mirror — and then redirecting again vertically. The currently measured divertor region remains available with this mirror retracted. Scattered light is collected from viewchords near the divertor floor using in-vacuum, high temperature optical elements and relayed through the port window, before being coupled into optical fiber bundles. At higher elevations from the floor, measurements are made by dynamically re-focusing the existing divertor system collection optics. Nd:YAG laser timing, analysis of the scattered light spectrum via polychromators, data acquisition, and calibration are all handled by existing systems or methods of the current multi-pulse Thomson scattering system. Existing filtered polychromators with 7 spectral channels are employed to provide maximum measurement breadth (T{sub e} in the range of 0.5 eV–2 keV, n{sub e} in the range of 5 × 10{sup 18}–1 × 10{sup 21} m{sup 3}) for both low T{sub e} in detachment and high T{sub e} measurement up beyond the separatrix.

  2. Spatial Expansion and Automation of the Pegasus Thomson Scattering Diagnostic System

    Science.gov (United States)

    Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Reusch, J. A.; Schlossberg, D. J.; Winz, G. R.

    2015-11-01

    The Pegasus Thomson scattering diagnostic system has recently undergone modifications to increase the spatial range of the diagnostic and automate the Thomson data collection process. Two multichannel spectrometers have been added to the original configuration, providing a total of 24 data channels to view the plasma volume. The new system configuration allows for observation of three distinct regions of the plasma: the local helicity injection (LHI) source (R ~ 67-73.8 cm), the plasma edge (R ~ 51.5-57.6 cm), and the plasma core (R ~ 35-41.1 cm). Each spectrometer utilizes a volume-phase holographic (VPH) grating and a gated-intensified CCD camera. The edge and the LHI spectrometers have been fitted with low-temperature VPH gratings to cover Te = 10 - 100 eV, while the core spectrometer has been fitted with a high-temperature VPH grating to cover Te = 0 . 1 - 1 . 0 keV. The additional spectrometers have been calibrated to account for detector flatness, detector linearity, and vignetting. Operation of the Thomson system has been overhauled to utilize LabVIEW software to synchronize the major components of the Thomson system with the Pegasus shot cycle and to provide intra-shot beam alignment. Multi-point Thomson scattering measurements will be obtained in the aforementioned regions of LHI and Ohmic discharges and will be compared to Langmuir probe measurements. Work supported by US DOE grant DE-FG02-96ER54375.

  3. Stray light analysis for the Thomson scattering diagnostic of the ETE Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Berni, L. A. [Instituto Nacional de Pesquisas Espaciais (INPE), Laboratorio Associado de Sensores e Materiais (LAS), 12.227-010 Sao Jose dos Campos, SP (Brazil); Albuquerque, B. F. C. [Instituto Nacional de Pesquisas Espaciais (INPE), Engenharia e Tecnologia Espaciais, Divisao de Eletronica Aeroespacial, 12.227-010 Sao Jose dos Campos, SP (Brazil)

    2010-12-15

    Thomson scattering is a well-established diagnostic for measuring local electron temperature and density in fusion plasma, but this technique is particularly difficult to implement due to stray light that can easily mask the scattered signal from plasma. To mitigate this problem in the multipoint Thomson scattering system implemented at the ETE (Experimento Tokamak Esferico) a detailed stray light analysis was performed. The diagnostic system was simulated in ZEMAX software and scattering profiles of the mechanical parts were measured in the laboratory in order to have near realistic results. From simulation, it was possible to identify the main points that contribute to the stray signals and changes in the dump were implemented reducing the stray light signals up to 60 times.

  4. Warm dense matter and Thomson scattering at FLASH

    International Nuclear Information System (INIS)

    Faeustlin, Roland Rainer

    2010-05-01

    X-ray free electron lasers are powerful tools to investigate moderately to strongly correlated solid density low temperature plasmas, named warm dense matter. These plasmas are of most interest for astrophysics and laser plasma interaction, particularly inertial confinement fusion. This work utilizes the ultrashort soft x-ray pulse duration and high brilliance of the free electron laser in Hamburg, FLASH, to generate warm dense matter and to study its ultrafast processes. The techniques applied are absorption measurement, emission spectroscopy and Thomson scattering. Radiative hydrodynamics and Thomson scattering simulations are used to investigate the impact of temperature and density gradients in the sample and to fit the experimental data. The measurements result in a comprehensive picture of soft x-ray matter interaction related to warm dense matter and yield insight into ultrafast equilibration and relaxation mechanisms, in particular impact ionization and radiative recombination. (orig.)

  5. Warm dense matter and Thomson scattering at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Faeustlin, Roland Rainer

    2010-05-15

    X-ray free electron lasers are powerful tools to investigate moderately to strongly correlated solid density low temperature plasmas, named warm dense matter. These plasmas are of most interest for astrophysics and laser plasma interaction, particularly inertial confinement fusion. This work utilizes the ultrashort soft x-ray pulse duration and high brilliance of the free electron laser in Hamburg, FLASH, to generate warm dense matter and to study its ultrafast processes. The techniques applied are absorption measurement, emission spectroscopy and Thomson scattering. Radiative hydrodynamics and Thomson scattering simulations are used to investigate the impact of temperature and density gradients in the sample and to fit the experimental data. The measurements result in a comprehensive picture of soft x-ray matter interaction related to warm dense matter and yield insight into ultrafast equilibration and relaxation mechanisms, in particular impact ionization and radiative recombination. (orig.)

  6. Thomson scattering diagnostic for the measurement of ion species fraction

    International Nuclear Information System (INIS)

    Ross, J. S.; Park, H.-S.; Amendt, P.; Divol, L.; Kugland, N. L.; Glenzer, S. H.; Rozmus, W.

    2012-01-01

    Simultaneous Thomson scattering measurements of collective electron-plasma and ion-acoustic fluctuations have been utilized to determine ion species fraction from laser produced CH plasmas. The CH 2 foil is heated with 10 laser beams, 500 J per beam, at the Omega Laser facility. Thomson scattering measurements are made 4 mm from the foil surface using a 30 J 2ω probe laser with a 1 ns pulse length. Using a series of target shots the plasma evolution is measured from 2.5 ns to 9 ns after the rise of the heater beams. Measuring the electron density and temperature from the electron-plasma fluctuations constrains the fit of the two-ion species theoretical form factor for the ion feature such that the ion temperature, plasma flow velocity and ion species fraction are determined. The ion species fraction is determined to an accuracy of ±0.06 in species fraction.

  7. Fast ion collective Thomson scattering diagnostic for ITER: Design elements

    DEFF Research Database (Denmark)

    Tsakadze, Erekle; Bindslev, Henrik; Korsholm, Søren Bang

    2008-01-01

    The proposed fast ion collective Thomson scattering (CTS) diagnostic system for ITER provides the unique capability of measuring the temporally and spatially resolved velocity distribution of the confined fast ions and fusion alpha particles in a burning ITER plasma. The present paper describes t...... in the studies, and new HFS receiver mock-up measurements are presented as well as neutron flux calculations of the influence of the increased slot height....

  8. Optical design of the TMX Thomson Scattering Diagnostic

    International Nuclear Information System (INIS)

    Frank, A.M.

    1979-01-01

    The Thomson Scattering Diagnostic on TMX was built to measure the electron temperature in the plug. The design was based on the 2XII system built by Tom Simonen. Substantial improvements were realized over the original design, these include: (1) improved sensitivity, (2) simultaneous multiple position sampling, (3) multiple pulse capability, (4) achromatic imaging, (5) vacuum alignment capability, (6) high reliability, and (7) built in calibration and performance monitoring

  9. High-rep-rate Thomson scattering for LHD

    Science.gov (United States)

    den Hartog, D. J.; Borchardt, M. T.; Holly, D. J.; Schmitz, O.; Yasuhara, R.; Yamada, I.; Funaba, H.; Osakabe, M.; Morisaki, T.

    2017-10-01

    A high-rep-rate pulse-burst laser system is being built for the LHD Thomson scattering (TS) diagnostic. This laser will have two operating scenarios, a fast-burst sequence of 15 kHz rep rate for at least 15 ms, and a slow-burst sequence of 1 kHz for at least 50 ms. There will be substantial flexibility in burst sequences for tailoring to experimental requirements. This new laser system will operate alongside the existing lasers in the LHD TS diagnostic, and will use the same beamline. This increase in temporal resolution capability complements the high spatial resolution (144 points) of the LHD TS diagnostic, providing unique measurement capability unmatched on any other fusion experiment. The new pulse-burst laser is a straightforward application of technology developed at UW-Madison, consisting of a Nd:YAG laser head with modular flashlamp drive units and a customized control system. Variable pulse-width drive of the flashlamps is accomplished by IGBT (insulated gate bipolar transistor) switching of electrolytic capacitor banks. Direct control of the laser Pockels cell drive enables optimal pulse energy extraction, producing >1.5 J q-switched pulses with 20 ns FWHM. Burst operation of this laser system will be used to capture fast time evolution of the electron temperature and density profiles during events such as ELMs, RMP perturbations, and various MHD modes. This work is supported by the U. S. Department of Energy and the National Institute for Fusion Science (Japan).

  10. APD detector electronics for the NSTX Thomson scattering system

    International Nuclear Information System (INIS)

    Johnson, D.W.; LeBlanc, B.P.; Long, D.L.; Renda, G.

    2000-01-01

    An electronics system has been installed and tested for the readout of APD detectors for the NSTX Thomson scattering system. Similar to previous designs, it features preamps with a fast and a slow output. The fast output uses pulse shaping to optimize sensitivity for the 8 nsec scattered light pulse while rejecting noise in the intrinsic plasma background. A low readout noise of approximately25 photoelectrons is achieved at an APD gain of 75. The design incorporates a number of features to provide flexibility for various modes of calibration

  11. Thomson scattering diagnostic for the Microwave Tokamak Experiment

    International Nuclear Information System (INIS)

    Foote, J.H.; Barter, J.D.; Sewall, N.R.; Jolly, J.J.; Schlander, L.F.

    1990-01-01

    The Thomson-scattering diagnostic system (TSS) on the Microwave Tokamak Experiment (MTX) at LLNL routinely monitors electron temperature (T e ) and density. Typical measured values at the plasma center under clean conditions are 900 ± 70 eV and 1 to 2 x 10 14 (±30%) cm -3 . The TSS apparatus is compact, with all elements mounted on one sturdy, two-level optics table. Because of this, we maintain with minimum effort the alignment of both the ruby-laser input optics and the scattered-light collecting optics. Undesired background signals, e.g., plasma light as well as ruby-laser light scattered off obstacles and walls, are generally small compared with the Thomson-scattered signals we normally detect. In the MTX T e region, the TSS data are definitely fitted better when relativistic effects are included in the equations. Besides determining the temperature of the Maxwellian electron distribution, the system is designed to detect electron heating from GW-level free-electron laser (FEL) pulses by measuring large wavelength shifts of the scattered laser photons. TSS data suggest that we may indeed by able to detect these electrons, which can have energies up to 10 keV, according to computer simulation. 7 refs., 4 figs

  12. Reasearches of Thomson Scattering X-Ray Source at Tsinghua University

    CERN Document Server

    Huang, Wenhui; Cheng, C; Cheng, Y; Du, Q; Du Tai Bin; Du, Y C; Ge, Y; He, X Z; Hua, J F; Huang, G; Lin, Y Z; Tang, C X; Xia, B; Xu, M J; Yuan, X D; Zheng, Sh X

    2004-01-01

    The bright and tunable short pulse X-ray sources are being widely used in various research fields including materials, chemistry, biology and solid physics. Thomson scattering source is one of the most promising approaches to short pulsed X-ray sources. Researches on Thomson scattering x-ray sources are being carried out in Tsinghua University. Some theoretical results and the preliminary experiment on the Thomson scattering between electron beams and laser pulses are described in this paper.

  13. Thomson scattering in the EXTRAP-T2 reversed-field pinch

    International Nuclear Information System (INIS)

    Welander, A.

    1996-11-01

    A Thomson scattering system has been installed on the EXTRAP-T2 RFP experiment. The system measures the electron density and temperature in three radial points using three spectral channels. A description of the system, the calibration techniques and examples of data obtained are given. The error bars for the electron temperature measurements are estimated to be < 10% for typical T2-plasmas. 4 refs

  14. Collective Thomson Scattering diagnostic for fusion product alpha particle measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Kondoh, Takashi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    2000-03-01

    In JT-60U, a pulsed CO{sub 2} laser (10.6 {mu}m 10 MW) have been developed to measure ion temperature and velocity distribution of fast ions to demonstrate feasibility of measurements of confined alpha particles in ITER. High power pulsed CO{sub 2} laser and heterodyne receiver system (a quantum-well infrared photodetector, QWIP) has been developed and installed in the diagnostic room (in collaboration with the Oak Ridge National Laboratory team). We describe the present states of the JT-60U CTS (Collective Thomson Scattering) system and also present a calculation of the scattered spectrum associated with the density and velocity distribution of energetic fusion produced alpha particles. Scattering of CO{sub 2} radiation is evaluated for the plasma condition for both ITER and JT-60U. (author)

  15. Progress of development of Thomson scattering diagnostic system on COMPASS

    Czech Academy of Sciences Publication Activity Database

    Bílková, Petra; Melich, Radek; Aftanas, Milan; Böhm, Petr; Šesták, David; Jareš, Daniel; Weinzettl, Vladimír; Stöckel, Jan; Hron, Martin; Pánek, Radomír; Scannell, R.; Walsh, M.

    2010-01-01

    Roč. 81, č. 10 (2010), 10D531-10D531 ISSN 0034-6748. [Topical Conference on High-Tempertaure Plasma Diagnostics/18th./. Wildwood, New Jersey, 16.05.2009-20.05.2009] R&D Projects: GA ČR GA202/09/1467; GA ČR GD202/08/H057; GA MŠk LA08048 Institutional research plan: CEZ:AV0Z20430508 Keywords : Thomson scattering * laser diagnostic * electron temperature * electron density * calibration Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.598, year: 2010 http://link.aip.org/link/?RSI/81/10D531

  16. Collective Thomson scattering measurements with high frequency resolution at TEXTOR

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Nielsen, Stefan Kragh; Korsholm, Søren Bang

    2010-01-01

    We discuss the development and first results of a receiver system for the collective Thomson scattering (CTS) diagnostic at TEXTOR with frequency resolution in the megahertz range or better. The improved frequency resolution expands the diagnostic range and utility of CTS measurements in general ...... and is a prerequisite for measurements of ion Bernstein wave signatures in CTS spectra. The first results from the new acquisition system are shown to be consistent with theory and with simultaneous measurements by the standard receiver system. © 2010 EURATOM...

  17. Thomson scattering on COMPASS – commissioning and first data

    Czech Academy of Sciences Publication Activity Database

    Aftanas, Milan; Böhm, Petr; Scannell, R.; Tripsky, M.; Weinzettl, Vladimír; Hron, Martin; Pánek, Radomír; Stöckel, Jan; Walsh, M.; Bílková, Petra

    2012-01-01

    Roč. 7, č. 1 (2012), C01074-C01074 ISSN 1748-0221. [INTERNATIONAL CONFERENCE ON LASER AIDED PLASMA DIAGNOSTICS/15./. Jeju, 13.10.2011-19.10.2011] R&D Projects: GA ČR GA202/09/1467 Institutional research plan: CEZ:AV0Z20430508 Keywords : Thomson scattering * electron temperature * laser diagnostic * Plasma diagnostics - charged-particle spectroscopy * Plasma diagnostics - interferometry * spectroscopy and imaging * tokamak Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.869, year: 2011 http://iopscience.iop.org/1748-0221/7/01/C01074/pdf/1748-0221_7_01_C01074.pdf

  18. Design of new Thomson scattering diagnostic system on COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Bílková, Petra; Aftanas, Milan; Böhm, Petr; Weinzettl, Vladimír; Šesták, David; Melich, Radek; Stöckel, Jan; Scannell, R.; Walsh, M.

    2010-01-01

    Roč. 623, č. 2 (2010), s. 656-659 ISSN 0168-9002. [International Conference on Frontiers in Diagnostic Technologies/1st./. Frascati, 25.11.2009-27.11.2009] R&D Projects: GA ČR GA202/09/1467; GA ČR GD202/08/H057 Institutional research plan: CEZ:AV0Z20430508 Keywords : Thomson scattering * Laser diagnostic * Electron temperature * Electron density Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.142, year: 2010 www.elsevier.com/locate/nima

  19. Collective Thomson scattering data analysis for Wendelstein 7-X

    DEFF Research Database (Denmark)

    Abramovic, I.; Pavone, A.; Svensson, J.

    2017-01-01

    Collective Thomson scattering (CTS) diagnostic is being installed on the Wendelstein 7-X stellarator to measure the bulk ion temperature in the upcoming experimental campaign. In order to prepare for the data analysis, a forward model of the diagnostic (eCTS) has been developed and integrated...... into the Bayesian data analysis framework Minerva. Synthetic spectra have been calculated with the forward model and inverted using Minerva in order to demonstrate the feasibility to measure the ion temperature in the presence of nuisance parameters that also influence CTS spectra. In this paper we report...... on the results of this anlysis and discuss the main sources of uncertainty in the CTS data analysis....

  20. Optical Thomson scatter from laser-ablated plumes

    International Nuclear Information System (INIS)

    Delserieys, A.; Khattak, F. Y.; Lewis, C. L. S.; Riley, D.; Pedregosa Gutierrez, J.

    2008-01-01

    We have obtained density and temperature informations on an expanding KrF laser-ablated magnesium plume via optical Thomson scatter with a frequency doubled Nd:YAG laser. The electron temperature was found to decay with the expected T e ∝t -1 dependence. However, we have found the electron density to have a time dependence n e ∝t -4.95 which can be explained by strong recombination processes. We also observed atomic Raman satellites originating from transitions between the different angular momentum levels of the metastable 3 P 0 term in Mg I

  1. The Thomson scattering system at Wendelstein 7-X

    Science.gov (United States)

    Pasch, E.; Beurskens, M. N. A.; Bozhenkov, S. A.; Fuchert, G.; Knauer, J.; Wolf, R. C.

    2016-11-01

    This paper describes the design of the Thomson scattering system at the Wendelstein 7-X stellarator. For the first operation campaign we installed a 10 spatial channel system to cover a radial half profile of the plasma cross section. The start-up system is based on one Nd:YAG laser with 10 Hz repetition frequency, one observation optics, five fiber bundles with one delay line each, and five interference filter polychromators with five spectral channels and silicon avalanche diodes as detectors. High dynamic range analog to digital converters with 14 bit, 1 GS/s are used to digitize the signals. The spectral calibration of the system was done using a pulsed super continuum laser together with a monochromator. For density calibration we used Raman scattering in nitrogen gas. Peaked temperature profiles and flat density profiles are observed in helium and hydrogen discharges.

  2. TFTR 60 GHz alpha particle collective Thomson Scattering diagnostic

    International Nuclear Information System (INIS)

    Machuzak, J.S.; Woskov, P.P.; Gilmore, J.; Bretz, N.L.; Park, H.K.; Bindslev, H.

    1995-03-01

    A 60 GHz gyrotron collective Thomson Scattering alpha particle diagnostic has been implemented for the D-T period on TFM. Gyrotron power of 0.1-1 kW in pulses of up to 1 second can be launched in X-mode. Efficient corrugated waveguides are used with antennaes and vacuum windows of the TFTR Microwave Scattering system. A multichannel synchronous detector receiver system and spectrum analyzer acquire the scattered signals. A 200 Megasample/sec digitizer is used to resolve fine structure in the frequency spectrum. By scattering nearly perpendicular to the magnetic field, this experiment will take advantage of an enhancement of the scattered signal which results from the interaction of the alpha particles with plasma resonances in the lower hybrid frequency range. Significant enhancements are expected, which will make these measurements possible with gyrotron power less than 1 kW, while maintaining an acceptable signal to noise ratio. We hope to extract alpha particle density and velocity distribution functions from the data. The D and T fuel densities and temperatures may also be obtainable by measurement of the respective ion cyclotron harmonic frequencies

  3. Progress on Thomson scattering in the Pegasus Toroidal Experiment

    Science.gov (United States)

    Schlossberg, D. J.; Bongard, M. W.; Fonck, R. J.; Schoenbeck, N. L.; Winz, G. R.

    2013-11-01

    A novel Thomson scattering system has been implemented on the Pegasus Toroidal Experiment where typical densities of 1019 m-3 and electron temperatures of 10 to 500 eV are expected. The system leverages technological advances in high-energy pulsed lasers, volume phase holographic (VPH) diffraction gratings, and gated image intensified (ICCD) cameras to provide a relatively low-maintenance, economical, robust diagnostic system. Scattering is induced by a frequency-doubled, Q-switched Nd:YAG laser (2 J at 532 nm, 7 ns FWHM pulse) directed to the plasma over a 7.7 m long beam path, and focused to VPH transmission gratings (eff. > 80%) and fast-gated ICCDs (gate > 2 ns, Gen III intensifier) with high-throughput (F/1.8), achromatic lensing. A stray light mitigation facility has been implemented, consisting of a multi-aperture optical baffle system and a simple beam dump. Successful stray light reduction has enabled detection of scattered signal, and Rayleigh scattering has been used to provide a relative calibration. Initial temperature measurements have been made and data analysis algorithms are under development.

  4. Multichannel Thomson scattering diagnostics for the GOL-3 facility

    International Nuclear Information System (INIS)

    Polosatkin, S. V.; Burdakov, A. V.; Ivantsivskii, M. V.; Koidan, V. S.; Ovchar, V. K.; Rovenskikh, A. F.; Semionov, V. V.; Fedotov, M. G.

    2006-01-01

    A multichannel Thomson scattering diagnostics for measuring the plasma parameters in the GOL-3 facility was designed and created at the Budker Institute of Nuclear Physics of the Siberian Division of the Russian Academy of Sciences. The diagnostics operates at the fundamental harmonic of a neodymium laser (1.06 μm) and allows one to perform measurements over a wide range of electron temperatures and densities with high spatial and time resolutions. A special multipulse oscillator is developed that makes it possible to perform up to 20 measurements of the plasma temperature and density over a period of 300 μs during one shot. The laser used to generate probing radiation, the recording system, and the calibration procedure are described. Results from measurements of the temporal evolution of the plasma density in the GOL-3 in different stages of the discharge are presented to illustrate the system operation

  5. Thomson scattering diagnostic upgrade on DIII-D

    International Nuclear Information System (INIS)

    Ponce-Marquez, D. M.; Bray, B. D.; Deterly, T. M.; Liu, C.; Eldon, D.

    2010-01-01

    The DIII-D Thomson scattering system has been upgraded. A new data acquisition hardware was installed, adding the capacity for additional spatial channels and longer acquisition times for temperature and density measurements. Detector modules were replaced with faster transimpedance circuitry, increasing the signal-to-noise ratio by a factor of 2. This allows for future expansion to the edge system. A second phase upgrade scheduled for 2010-2011 includes the installation of four 1 J/pulse Nd:YAG lasers at 50 Hz repetition rate. This paper presents the first completed phase of the upgrade and performance comparison between the original system and the upgraded system. The plan for the second phase is also presented.

  6. Enhanced Thomson scattering theory applied to eight experiments

    International Nuclear Information System (INIS)

    Simon, A.; Short, R.W.; Seka, W.; Goldman, L.M.

    1985-01-01

    The onset of an instability, such as the 2ω/sub p/ at the n/sub c//4 surface, usually leads to wave breaking and the emission of hot electron pulses which can profoundly influence instability thresholds and scattering behavior elsewhere in the plasma. In particular, enhanced Thomson scattering (via the plasma line) can occur, and this has been used to explain the observation of the SRS instability well below the theoretical threshold. A simple model of the hot electron pulses based on measured values of the hot and cold electron temperatures, T/sub h/ and T/sub c/, has yielded good agreement with experimental observation of the Raman spectral frequency bands. The agreement has continued, even for experiments which are clearly above the SRS threshold, with the enhanced noise likely acting as a ''seed'' for the SRS growth. We will show details of the successful comparison of this theory with six experiments carried out on SHIVA, ARGUS, NOVETTE(2), and GDL(2), and also with an upscattering feature seen at Garching. In addition, a recent experiment using 6 beams of OMEGA (at 0.35μ) will be discussed, and compared with the theory. The report is comprised of viewgraphs of the talks

  7. X-ray Thomson Scattering from Spherically Imploded ICF Ablators

    Science.gov (United States)

    Kritcher, Andrea; Doeppner, Tilo; Landen, Otto; Glenzer, Siegfried

    2010-11-01

    Time-resolved X-ray Thomson scattering measurements from spherically imploded inertial fusion capsules-type targets have been obtained for the first time at the Omega OMEGA laser facility to characterize the in-flight properties of ICF ablators. In these experiments, the non-collective, or microscopic particle behavior, of imploding CH and Be shells, was probed using a 9 keV Zn He-alpha x-ray source at scattering angles of 113^o and 135^o. for two drive pulse shapes.As an example, the analysis of In-flight scattering measurements from one set of directly-driven compressed 8600 μm-diameter, 40-μm thick Be shells taken (4.2 ns after the start of the compression beamswhen compressed a factor of 4.83x) yielded electron densities of ˜ 1.2±0.23x10^24cm-3, temperatures of ˜13±32 eV, and an ionization state of Be(+2), with uncertainties in the temperature and density of about 40% and 20%. These conditions resulting in an inferred adiabat (ratio of plasma pressure to Fermi degenerate pressure) of 1.797 +0.3/-.5 with an error of about 30%. The high signal-to-noise and high signal-to-background ratio of data obtained in these experiments provides a platform for studying the adiabat of other indirect-drive ICF ablators such as CH and High Density Carbon (HDC) ablators and demonstrates the viability of using this diagnostic to study the in-flight properties adiabat of implosion targets at the National Ignition Facility (NIF).

  8. X-Ray Thomson Scattering Without the Chihara Decomposition

    Science.gov (United States)

    Magyar, Rudolph; Baczewski, Andrew; Shulenburger, Luke; Hansen, Stephanie B.; Desjarlais, Michael P.; Sandia National Laboratories Collaboration

    X-Ray Thomson Scattering is an important experimental technique used in dynamic compression experiments to measure the properties of warm dense matter. The fundamental property probed in these experiments is the electronic dynamic structure factor that is typically modeled using an empirical three-term decomposition (Chihara, J. Phys. F, 1987). One of the crucial assumptions of this decomposition is that the system's electrons can be either classified as bound to ions or free. This decomposition may not be accurate for materials in the warm dense regime. We present unambiguous first principles calculations of the dynamic structure factor independent of the Chihara decomposition that can be used to benchmark these assumptions. Results are generated using a finite-temperature real-time time-dependent density functional theory applied for the first time in these conditions. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Security Administration under contract DE-AC04-94AL85000.

  9. Measurements of the electron energy spectrum by using small-angle Thomson scattering

    International Nuclear Information System (INIS)

    Popov, S. S.; Burdakov, A. V.; Vyacheslavov, L. N.; Ivantsivskii, M. V.; Ovchar, V. K.; Polosatkin, S. V.; Rovenskikh, A. F.; Fedotov, M. G.

    2008-01-01

    A novel diagnostic method is developed for studying the high-energy plasma electron component in the GOL-3 facility by using small-angle Thomson scattering. The method is based on the enhancement of the spectral density of scattered radiation as compared to the conventional large-angle scattering technique.

  10. Measurements of the electron energy spectrum by using small-angle Thomson scattering

    Science.gov (United States)

    Popov, S. S.; Burdakov, A. V.; Vyacheslavov, L. N.; Ivantsivskii, M. V.; Ovchar, V. K.; Polosatkin, S. V.; Rovenskikh, A. F.; Fedotov, M. G.

    2008-03-01

    A novel diagnostic method is developed for studying the high-energy plasma electron component in the GOL-3 facility by using small-angle Thomson scattering. The method is based on the enhancement of the spectral density of scattered radiation as compared to the conventional large-angle scattering technique.

  11. A simple, high performance Thomson scattering diagnostic for high temperature plasma research

    International Nuclear Information System (INIS)

    Hartog, D.J.D.; Cekic, M.

    1994-02-01

    This Thomson scattering diagnostic is used to measure the electron temperature and density of the plasma in the MST reversed-field pinch, a magnetic confinement fusion research device. This diagnostic system is unique for its type in that it combines high performance with simple design and low cost components. In the design of this instrument, careful attention was given to the suppression of stray laser line light with simple and effective beam dumps, viewing dumps, aperatures, and a holographic edge filter. This allows the use of a single grating monochromator for dispersion of the Thomson scattered spectrum onto the microchannel plate detector. Alignment and calibration procedures for the laser beam delivery system, the scattered light collection system, and the spectrometer and detector are described. A sample Thomson scattered spectrum illustrates typical data

  12. High resolution Thomson scattering system for steady-state linear plasma sources

    Science.gov (United States)

    Lee, K. Y.; Lee, K. I.; Kim, J. H.; Lho, T.

    2018-01-01

    The high resolution Thomson scattering system with 63 points along a 25 mm line measures the radial electron temperature (Te) and its density (ne) in an argon plasma. By using a DC arc source with lanthanum hexaboride (LaB6) electrode, plasmas with electron temperature of over 5 eV and densities of 1.5 × 1019 m-3 have been measured. The system uses a frequency doubled (532 nm) Nd:YAG laser with 0.25 J/pulse at 20 Hz. The scattered light is collected and sent to a triple-grating spectrometer via optical-fibers, where images are recorded by an intensified charge coupled device (ICCD) camera. Although excellent in stray-light reduction, a disadvantage comes with its relatively low optical transmission and in sampling a tiny scattering volume. Thus requires accumulating multitude of images. In order to improve photon statistics, pixel binning in the ICCD camera as well as enlarging the intermediate slit-width inside the triple-grating spectrometer has been exploited. In addition, the ICCD camera capture images at 40 Hz while the laser is at 20 Hz. This operation mode allows us to alternate between background and scattering shot images. By image subtraction, influences from the plasma background are effectively taken out. Maximum likelihood estimation that uses a parameter sweep finds best fitting parameters Te and ne with the incoherent scattering spectrum.

  13. The spectrometer of the High-Resolution Multi position Thomson Scattering Diagnostic for TJ-II

    Energy Technology Data Exchange (ETDEWEB)

    Herranz, J.; Barth, C.J.; Castejon, F.; Lopez-Sanchez, A.; Mirones, E.; Pastor, I.; Perez, D.; Rodriguez, C.

    2001-07-01

    Since 1998, a high-resolution multiposition thompson scattering system is in operation at the stellarator TJ-II, combining high accuracy and excellent spatial resolution. A description of the diagnostic spectrometer is presented. The main characteristics of the spectrometer that allow YJ-II Thomson scattering diagnostic to have high spatial and spectral resolution are described in this paper. (Author)

  14. Preliminary project of s Thomson scattering system for the ETE tokamak

    International Nuclear Information System (INIS)

    Berni, Luiz Angelo

    1997-01-01

    This report presents the preliminary project of the injection and laser light block system for the Thomson (ET) scattering diagnostic to be implanted at the ETE spheric tokamak of the Instituto Nacional de Pesquisas Espaciais (INPE/LAP). Also, a scanning system for the optics of scattered light

  15. CO2 laser Thomson scattering diagnostic for fusion product alpha particle measurement

    Science.gov (United States)

    Richards, R. K.; Bennett, C. A.; Fletcher, L. K.; Hunter, H. T.; Hutchinson, D. P.

    1988-08-01

    A description of a CO2 laser Thomson scattering diagnostic for fusion product alpha particles is presented. Scattering calculations based on CIT plasma parameters are presented and compared to previous work based on TFTR parameters. System components are described and a proof-of-principle test in a nonburning plasma is discussed.

  16. A CO2 laser Thomson scattering diagnostic for fusion product alpha particle measurement

    Science.gov (United States)

    Richards, R. K.; Bennett, C. A.; Fletcher, L. K.; Hunter, H. T.; Hutchinson, D. P.

    A description of a CO2 laser Thomson scattering diagnostic for fusion alpha particles is presented. Scattering calculations based on CIT plasma parameters are presented and compared to previous work based on TFTR parameters. Systems components are described and a proof-of-principle test in a nonburning plasma is discussed.

  17. A CO2 Laser Thomson Scattering Diagnostic For The Measurement Of Fusion Product Alpha Particles

    Science.gov (United States)

    Richards, R. K.; Bennett, C. A.; Fletcher, L. K.; Hunter, H. T.; Hutchinson, D. P.

    1988-11-01

    A Thomson scattering diagnostic for measuring the alpha particle velocity distribution is described. Calculations of scattering are made for a CIT type plasma using available CO2 laser and heterodyne technology. Tests of a long pulse CO2 laser, multichannel heterodyne detector, and an absorption cell for stray laser radiation are presented.

  18. The spectrometer of the High-Resolution Multi position Thomson Scattering Diagnostic for TJ-II

    International Nuclear Information System (INIS)

    Herranz, J.; Barth, C. J.; Castejon, F.; Lopez-Sanchez, A.; Mirones, E.; Pastor, I.; Perez, D.; Rodriguez, C.

    2001-01-01

    Since 1998, a high-resolution multiposition thompson scattering system is in operation at the stellarator TJ-II, combining high accuracy and excellent spatial resolution. A description of the diagnostic spectrometer is presented. The main characteristics of the spectrometer that allow YJ-II Thomson scattering diagnostic to have high spatial and spectral resolution are described in this paper. (Author)

  19. Progress on the multipulse Thomson Scattering diagnostic on DIII-D

    International Nuclear Information System (INIS)

    Stockdale, R.E.; Carlstrom, T.N.; Hsieh, C.L.; Makariou, C.C.

    1994-05-01

    The DIII-D Thomson scattering diagnostic, operational since 1990, uses 8 Nd: YAG 20 Hz lasers to measure electron temperature and density profiles (40 spatial points) throughout the plasma discharge. Recent progress has enabled a new set of operating modes to better fullfill varying plasma physics requirements. Custom circuitry for laser control (programmable with los precision) has successfully replaced a previous scheme which used real-time 68030 software. Two new modes of operation have been demonstrated. Burst Mode is useful to study a transient plasma event: a series of laser pulses axe fired at a rate ≤10 kHz after an external asynchronous event trigger. Burst Mode is also useful to synchronize the Thomson lasers with other systems, such as an asynchronous Michelson ECE diagnostic scanning near 40 Hz. Group Mode allows a programmed set of lasers to fire simultaneously into the same (65 nanosecond) data acquisition gate. Improved signal/noise then yields smaller statistical errors in the profile results. This provides profile data for lower density plasmas, such as those anticipated during fast wave current drive experiments. Plans for a new CCD-based laser alignment system for position monitoring and feedback control will also be presented

  20. Iterative noise removal from temperature and density profiles in the TJ-II Thomson scattering

    International Nuclear Information System (INIS)

    Farias, G.; Dormido-Canto, S.; Vega, J.; Santos, M.; Pastor, I.; Fingerhuth, S.; Ascencio, J.

    2014-01-01

    TJ-II Thomson Scattering diagnostic provides temperature and density profiles of plasma. The CCD camera acquires images that are corrupted with some kind of noise called stray-light. This noise degrades both image contrast and measurement accuracy, which could produce unreliable profiles of the diagnostic. So far, several approaches have been applied in order to decrease the noise in the TJ-II Thomson scattering images. Since the presence of the noise is not global but located in some particular regions of the image, advanced processing techniques are needed. However such methods require of manual fine-tuning of parameters to reach a good performance. In this contribution, an iterative image processing approach is applied in order to reduce the stray light effects in the images of the TJ-II Thomson scattering diagnostic. The proposed solution describes how the noise can be iteratively reduced in the images when a key parameter is automatically adjusted during the iterative process

  1. Iterative noise removal from temperature and density profiles in the TJ-II Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Farias, G., E-mail: gonzalo.farias@ucv.cl [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile); Dormido-Canto, S., E-mail: sebas@dia.uned.es [Departamento de Informática y Automática, UNED, 28040 Madrid (Spain); Vega, J., E-mail: jesus.vega@ciemat.es [Asociación EURATOM/CIEMAT para Fusión, Avd. Complutense 22, 28040 Madrid (Spain); Santos, M., E-mail: msantos@ucm.es [Departamento de Arquitectura de Computadores y Automática, Universidad Complutense de Madrid, 28040 Madrid (Spain); Pastor, I., E-mail: ignacio.pastor@ciemat.es [Asociación EURATOM/CIEMAT para Fusión, Avd. Complutense 22, 28040 Madrid (Spain); Fingerhuth, S., E-mail: sebastian.fingerhuth@ucv.cl [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile); Ascencio, J., E-mail: j_ascencio21@hotmail.com [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile)

    2014-05-15

    TJ-II Thomson Scattering diagnostic provides temperature and density profiles of plasma. The CCD camera acquires images that are corrupted with some kind of noise called stray-light. This noise degrades both image contrast and measurement accuracy, which could produce unreliable profiles of the diagnostic. So far, several approaches have been applied in order to decrease the noise in the TJ-II Thomson scattering images. Since the presence of the noise is not global but located in some particular regions of the image, advanced processing techniques are needed. However such methods require of manual fine-tuning of parameters to reach a good performance. In this contribution, an iterative image processing approach is applied in order to reduce the stray light effects in the images of the TJ-II Thomson scattering diagnostic. The proposed solution describes how the noise can be iteratively reduced in the images when a key parameter is automatically adjusted during the iterative process.

  2. Measurement of electron temperature and density by Thomson scattering diagnostic on the Tokamak CASTOR

    Czech Academy of Sciences Publication Activity Database

    Brotánková, Jana; Plíšek, Pavel; Žáček, František

    2002-01-01

    Roč. 52, supplement D (2002), s. 51-58 ISSN 0011-4626. [Symposium on Plasma Physics and Technology/20th./. Prague, 10.06.2002-13.06.2002] Institutional research plan: CEZ:AV0Z2043910 Keywords : tokamak, Thomson scattering, electron temperature Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.311, year: 2002

  3. Investigations of laser-induced plasma in argon by Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Mendys, A., E-mail: agata.mendys@uj.edu.pl [Instytut Fizyki im. M. Smoluchowskiego, Uniwersytet Jagiellonski, ulica Reymonta 4, 30-059 Krakow (Poland); Dzierzega, K.; Grabiec, M. [Instytut Fizyki im. M. Smoluchowskiego, Uniwersytet Jagiellonski, ulica Reymonta 4, 30-059 Krakow (Poland); Pellerin, S. [GREMI - site de Bourges, Universite d' Orleans, CNRS, rue Gaston Berger BP 4043, 18028 Bourges (France); Pokrzywka, B. [Obserwatorium Astronomiczne na Suhorze, Uniwersytet Pedagogiczny, ulica Podchorazych 2, 30-084 Krakow (Poland); Travaille, G.; Bousquet, B. [Centre de Physique Moleculaire Optique et Hertzienne, Universite Bordeaux 1, 351 Cours de la Liberation, 33405 Talence CEDEX (France)

    2011-09-15

    The Thomson scattering method was applied to quantify the electron number density and temperature of a laser spark formed in argon. The laser spark was generated by focusing a 15 mJ beam from the second harmonic ({lambda}{sub L} = 532 nm) of a nanosecond Nd:YAG laser with an 80 mm focal length lens. Images of the spark emission were obtained for times between 1 ns and 20 {mu}s after the laser pulse in order to characterize its spatial evolution. The electron density and temperature for the core of the plasma plume at different instants of its evolution were determined from the Thomson scattered spectra of another nanosecond Nd:YAG laser (532 nm, 10 to 60 mJ/pulse). In the time interval between 400 ns and 10 {mu}s between the laser induced plasma and Thomson scattering probe pulses, we found n{sub e} and T{sub e} to decrease from 4.3 Multiplication-Sign 10{sup 23} m{sup -3} to 2.4 Multiplication-Sign 10{sup 22} m{sup -3} and from 50 700 K to 11 100 K, respectively. Special care was paid to the plasma disturbance by the probe laser pulse in Thomson scattering experiments due to absorption of laser photons by electrons through the inverse bremsstrahlung process.

  4. Temporal evolution of confined fast-ion velocity distributions measured by collective Thomson scattering in TEXTOR

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Bindslev, Henrik; Porte, L.

    2008-01-01

    Fast ions created in the fusion processes will provide up to 70% of the heating in ITER. To optimize heating and current drive in magnetically confined plasmas insight into fast-ion dynamics is important. First measurements of such dynamics by collective Thomson scattering (CTS) were recently rep...

  5. Calibration procedure and data processing for a TV Thomson scattering system

    NARCIS (Netherlands)

    Barth, C. J.; Chu, C.C.; Beurskens, M. N. A.; van der Meiden, H. J.

    2001-01-01

    Calibration procedures for Thomson scattering systems based on television-like cameras, so-called TVTS systems, are described. The TVTS systems of the Rijnhuizen Tokamak Project (RTP), the TJ-II stellarator, and the Torus Experiment for Technology Oriented Research (TEXTOR) tokamak combine a 10-15 J

  6. Dynamics of fast ions during sawtooth oscillations in the TEXTOR tokamak measured by collective Thomson scattering

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Salewski, Mirko; Bindslev, Henrik

    2011-01-01

    Experimental investigations of sawteeth interaction with fast ions measured by collective Thomson scattering on TEXTOR are presented. Time-resolved measurements of localized 1D fast-ion distribution functions allow us to study fast-ion dynamics during several sawtooth cycles. Sawtooth oscillation...

  7. Recent development of collective Thomson scattering for magnetically confined fusion plasmas

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Michelsen, Poul; Hansen, S.K.

    2017-01-01

    Here we review recent experimental developments within the field of collective Thomson scattering with a focus on the progress made on the devices TEXTOR and ASDEX Upgrade. We discuss recently discovered possibilities and limitations of the diagnostic technique. Diagnostic applications with respect...

  8. Temporally resolved plasma composition measurements by collective Thomson scattering in TEXTOR

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Korsholm, Søren Bang; Nielsen, Stefan Kragh

    2012-01-01

    Fusion plasma composition measurements by collective Thomson scattering (CTS) were demonstrated in recent proof-of-principle measurements in TEXTOR [S. B. Korsholm et al., Phys. Rev. Lett. 106, 165004 (2011)]. Such measurements rely on the ability to resolve and interpret ion cyclotron structure ...

  9. Soft X-Ray Thomson Scattering in Warm Dense Hydrogen at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Faustlin, R R; Toleikis, S; Bornath, T; Doppner, T; Dusterer, S; Forster, E; Fortmann, C; Glenzer, S H; Gode, S; Gregori, G; Irsig, R; Laarmann, T; Lee, H J; Li, B; Meiwes-Broer, K; Mithen, J; Przystawik, A; Redlin, H; Redmer, R; Reinholz, H; Ropke, G; Tavella, F; Thiele, R; Tiggesbaumker, J; Uschmann, I; Zastrau, U; Tschentscher, T

    2009-07-15

    We present collective Thomson scattering with soft x-ray free electron laser radiation as a method to track the evolution of warm dense matter plasmas with {approx}200 fs time resolution. In a pump-probe scheme an 800 nm laser heats a 20 {micro}m hydrogen droplet to the plasma state. After a variable time delay in the order of ps the plasma is probed by an x-ray ultra violet (XUV) pulse which scatters from the target and is recorded spectrally. Alternatively, in a self-Thomson scattering experiment, a single XUV pulse heats the target while a portion of its photons are being scattered probing the target. From such inelastic x-ray scattering spectra free electron temperature and density can be inferred giving insight on relaxation time scales in plasmas as well as the equation of state. We prove the feasibility of this method in the XUV range utilizing the free electron laser facility in Hamburg, FLASH. We recorded Thomson scattering spectra for hydrogen plasma, both in the self-scattering and in the pump-probe mode using optical laser heating.

  10. Dielectric effects on Thomson scattering in a relativistic magnetized plasma

    DEFF Research Database (Denmark)

    Bindslev, H.

    1991-01-01

    The effects of the dielectric properties of a relativistic magnetized plasma on the scattering of electromagnetic radiation by fluctuations in electron density are investigated. The origin of the density fluctuations is not considered. Expressions for the scattering cross-section and the scattered...

  11. Electron temperature (Мe) measurements by Thomson scattering ...

    Indian Academy of Sciences (India)

    power is the simple sum of the scattered powers from each individual electron present in the observed scattering volume. For the assumption of electrons with simple Maxwellian velocity distribution, the scattered power at right angles to the incident wave and polariza- tion vectors of the laser beam is given by Selden Model ...

  12. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Kiran, E-mail: kkpatel@ipr.res.in; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-11-15

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  13. A high-power spatial filter for Thomson scattering stray light reduction

    Science.gov (United States)

    Levesque, J. P.; Litzner, K. D.; Mauel, M. E.; Maurer, D. A.; Navratil, G. A.; Pedersen, T. S.

    2011-03-01

    The Thomson scattering diagnostic on the High Beta Tokamak-Extended Pulse (HBT-EP) is routinely used to measure electron temperature and density during plasma discharges. Avalanche photodiodes in a five-channel interference filter polychromator measure scattered light from a 6 ns, 800 mJ, 1064 nm Nd:YAG laser pulse. A low cost, high-power spatial filter was designed, tested, and added to the laser beamline in order to reduce stray laser light to levels which are acceptable for accurate Rayleigh calibration. A detailed analysis of the spatial filter design and performance is given. The spatial filter can be easily implemented in an existing Thomson scattering system without the need to disturb the vacuum chamber or significantly change the beamline. Although apertures in the spatial filter suffer substantial damage from the focused beam, with proper design they can last long enough to permit absolute calibration.

  14. Electron kinetic effects on interferometry, polarimetry and Thomson scattering measurements in burning plasmas (invited)a)

    Science.gov (United States)

    Mirnov, V. V.; Brower, D. L.; Hartog, D. J. Den; Ding, W. X.; Duff, J.; Parke, E.

    2014-11-01

    At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP), and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. The precision of the previous lowest order linear in τ = Te/mec2 model may be insufficient; we present a more precise model with τ2-order corrections to satisfy the high accuracy required for ITER TIP and PoPola diagnostics. The linear model is extended from Maxwellian to a more general class of anisotropic electron distributions that allows us to take into account distortions caused by equilibrium current, ECRH, and RF current drive effects. The classical problem of the degree of polarization of incoherent Thomson scattered radiation is solved analytically exactly without any approximations for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. The results are discussed in the context of the possible use of the polarization properties of Thomson scattered light as a method of Te measurement relevant to ITER operational scenarios.

  15. Electron Beam Final Focus System For Thomson Scattering At Elbe

    CERN Document Server

    Krämer, J.M.; Bødkera, F.; Irman, A.; Jochmann, A.; Kristensena, J.P.; Lehnert, U.; Michel, P.; Schramm, U.; 10.1016/j.nima.2015.10.067

    2016-01-01

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and diverg...

  16. Electron beam final focus system for Thomson scattering at ELBE

    CERN Document Server

    Krämer, J.M.; Bødker, F.; Irman, A.; .Jochmann A.; Kristensen, J.P.; Lehnert U., HZDR; Michel, P.; Schrammb, U.; 10.1016/j.nima.2015.10.067

    2016-01-01

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and diverg...

  17. Measurement of CO2 laser small angle Thomson scattering on a magnetically confined plasma

    Science.gov (United States)

    Richards, R. K.; Hutchinson, D. P.; Bennett, C. A.; Hunter, H. T.; Ma, C. H.

    1993-01-01

    We report the first successful small-angle (less than 1°) Thomson scattering measurement of 10 μm radiation from a magnetically confined toroidal plasma. This represents a proof-of-principle demonstration of a new diagnostic technique for confined deuterium-tritium fusion-product alpha particles in future fusion reactors. This result was achieved by detecting scattered CO2 laser light from the plasma of the ATF torsatron at an angle of 0.86° using a novel heterodyne receiver scheme. A predicted resonance in the scattered power as a function of plasma electron density is clearly resolved in the measurements.

  18. Impact of beam ions on α-particle measurements by collective Thomson scattering in ITER

    DEFF Research Database (Denmark)

    Egedal, J.; Bindslev, H.; Budny, R.V.

    2005-01-01

    Collective Thomson scattering (CTS) has been proposed as a viable diagnostic for characterizing fusion born a-distributions in ITER. However, the velocities of the planned 1 MeV deuterium heating beam ions in 1TER are similar to that of fusion born a-particles and may therefore mask the measureme......Collective Thomson scattering (CTS) has been proposed as a viable diagnostic for characterizing fusion born a-distributions in ITER. However, the velocities of the planned 1 MeV deuterium heating beam ions in 1TER are similar to that of fusion born a-particles and may therefore mask...... and the alpha-particles are calculated. Our investigations show that the CTS measurements of alpha-particles will not be masked by the presence of the beam ions in H-mode plasmas. In lower density reversed shear plasmas, only a part of the CTS alpha-particle spectrum will be perturbed....

  19. Material Assessment for ITER’s Collective Thomson Scattering first mirror

    DEFF Research Database (Denmark)

    Santos, R.; Policarpo, H.; Gonçalves, B.

    2015-01-01

    ITER’s Collective Thomson Scattering (CTS) system is a diagnostic instrument that will measure the plasma density and velocity through Thomson scattering of microwave radiation. Some of the key components of the CTS are quasioptical mirrors used to produce astigmatic beam patterns, which have....... In this work, three different materials (molybdenum (Mo), stainless steel 316L (SS-316L) and tungsten (W)) are considered for the first mirror of the CTS. The objective is to assess the suitability of these materials for this mirror and to provide a first ranking, considering the neutron radiation loads...... requirements defined by ITER, based on the resultant maximum Von Misses stresses and temperatures. For it, the neutron irradiation, and subsequent heat-load on the mirrors were simulated using the Monte Carlo N-Particle (MCNP) code. Based on the MCNP heat-load results, a transient thermal-structural Finite...

  20. A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Shumei; Zang, Qing, E-mail: zangq@ipp.ac.cn; Han, Xiaofeng; Wang, Tengfei; Zhao, Junyu [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei, Anhui 230031 (China); Yu, Jin [Academy of Opto-Electronics, Chinese Academy of Sciences, Beijing 100094 (China)

    2016-07-15

    Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump system can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.

  1. High time resolved electron temperature measurements by using the multi-pass Thomson scattering system in GAMMA 10/PDX

    OpenAIRE

    Yoshikawa, Masayuki; Yasuhara, Ryo; Ohta, Koichi; Chikatsu, Masayuki; Shima, Yoriko; Kohagura, Junko; Sakamoto, Mizuki; Nakashima, Yousuke; Imai, Tsuyoshi; Ichimura, Makoto; Yamada, Ichihiro; Funaba, Hisamichi; Minami, Takashi

    2016-01-01

    High time resolved electron temperature measurements are useful for fluctuation study. A multi-pass Thomson scattering (MPTS) system is proposed for the improvement of both increasing the TS signal intensity and time resolution. The MPTS system in GAMMA 10/PDX has been constructed for enhancing the Thomson scattered signals for the improvement of measurement accuracy. The MPTS system has a polarization-based configuration with an image relaying system. We optimized the image relaying optics f...

  2. Study of TJ-1 Tokamak plasmas with Thomson scattering and radiation diagnostics

    International Nuclear Information System (INIS)

    Pardo, C.; Zurro, B.

    1987-06-01

    The Thomson scattering system of TJ-1 is described in detail. The radial profiles of T e and n e obtained in TJ-1 discharges are presented. This data makes possible to deduce characteristic parameters of the plasma confinement in this machine, as energy confinement times, Z eff B. Using also radiation measurements (global and in the visible range) we obtained the particle confinement time and Z eff without non experimental assumptions. (author) 56 figs., 52 refs

  3. Fast ion dynamics in ASDEX upgrade and TEXTOR measured by collective Thomson scattering

    International Nuclear Information System (INIS)

    Moseev, D.

    2011-11-01

    Fast ions are an essential ingredient in burning nuclear fusion plasmas: they are responsible for heating the bulk plasma, carry a significant amount of plasma current and moreover interact with various magnetohydrodynamic (MHD) instabilities. The collective Thomson scattering (CTS) diagnostic is sensitive to the projection of fast ion velocity distribution function. This thesis is mainly devoted to investigations of fast ion physics in tokamak plasmas by means of CTS. (Author)

  4. Collective thomson scattering based on pulsed CO{sub 2} laser in JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Kondoh, Takashi; Lee, S.; Tsukahara, Yoshimitsu [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    2000-03-01

    In JT-60U, a collective Thomson scattering system (CTS system) based on a pulsed CO{sub 2} laser (10.6 {mu}m, 10J, 1 {mu}s) have been developed to measure ion temperature and fast-ion velocity distribution and also to demonstrate feasibility of measurements of confined alpha particles and ion temperature in ITER. In this paper, we describe the present status of the JT-60U CTS system. (author)

  5. Fast ion dynamics in ASDEX upgrade and TEXTOR measured by collective Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Moseev, D.

    2011-11-15

    Fast ions are an essential ingredient in burning nuclear fusion plasmas: they are responsible for heating the bulk plasma, carry a significant amount of plasma current and moreover interact with various magnetohydrodynamic (MHD) instabilities. The collective Thomson scattering (CTS) diagnostic is sensitive to the projection of fast ion velocity distribution function. This thesis is mainly devoted to investigations of fast ion physics in tokamak plasmas by means of CTS. (Author)

  6. Progress On The Thomson Scattering Diagnostic For The Helicon Plasma Experiment (HPX)

    Science.gov (United States)

    Green, A.; Emami, T.; Davies, R.; Frank, J.; Hopson, J.; Karama, J.; James, R. W.; Hopson, J.; Paolino, R. N.; Sandri, E.; Turk, J.; Wicke, M.; Cgapl Team

    2017-10-01

    A high-performance spectrometer utilizing volume-phase-holographic (VPH) grating and a charge coupled device (CCD) camera with a range of 380-1090 nm and resolution of 1024x1024 has been assembled on HPX at the Coast Guard Academy Plasma Laboratory (CGAPL). This spectrometer will collect doppler shifted photons, emitted from the plasma by the first harmonic (1064 nm) of a 2.5 J Nd:YAG laser. Direct measurements of the plasma's temperature and density will be determined using HPX's Thomson Scattering (TS) single spatial point diagnostic system. A zero order half wave plate rotates the polarization of the second harmonic TS laser beam when operating at a wavelength of 532 nm. A linear actuated periscope has been constructed to remotely redirect the beam so that 532 and 1064 nm wavelengths can both be used. TS has the capability of determining plasma properties on short time scales and will be used to create a robust picture of the internal plasma parameters. Operating at both 532 and 1064 nm results in a self-consistent measurement and better use our existing spectrometer and soon to be constructed polychrometer. A prototype spectrometer has been constructed to explore the Andor CCD camera's resolution and sensitivity. The current status of the diagnostic development, spectrometer, and collection optics system will be reported. Supported by U.S. DEPS Grant [HEL-JTO] PRWJFY17.

  7. Use of fast scopes to enable Thomson scattering measurement in presence of fluctuating plasma light

    International Nuclear Information System (INIS)

    McLean, H.S.; Moller, J.; Hill, D.N.

    2004-01-01

    The addition of inexpensive high-speed oscilloscopes has enabled higher T e Thomson scattering measurements on the Sustained Spheromak Physics Experiment. Along with signal correlation techniques, the scopes allow analyses based on the shape of the scattered laser pulse to discriminate against fluctuating background plasma light that often make gated-integrator measurements unreliable. A 1.4 J Nd:YAG laser at 1064 nm is the scattering source. Spatial locations are coupled by viewing optics and fibers to four-wavelength-channel filter polychrometers. Ratios between the channels determine T e while summations of the channels determine density. Typically, the channel that provides a scattered signal at higher T e is contaminated by fluctuating background light. Individual channels are correlated with either a modeled representation of the laser pulse or a noise-free scattered laser light signal to extract channel amplitudes

  8. Thomson scattering measurements on the high beta pinch Extrap-T1

    International Nuclear Information System (INIS)

    Karlsson, P.

    1989-11-01

    Electron temperature and density measurement on a high beta discharge in the Extrap-T1 device have been performed with Thomson scattering. It was found that the signal levels were low and the plasma background radiation high. The spread of the measured temperatures and densities was large. A computer code was developed to investigate whether this spread in measured temperatures was due to shot to shot variations or to photon statistics. The code showed that the scattered data could be explained by photon statistics

  9. ITER fast ion collective Thomson scattering. Conceptual design of 60 GHz system

    DEFF Research Database (Denmark)

    Meo, Fernando; Bindslev, Henrik; Korsholm, Søren Bang

    The collective Thomson scattering diagnostic for ITER at the 60 GHz range is capable of measuring the fast ion distribution parallel and perpendicular to the magnetic field at different radial locations simultaneously. The design is robust technologically with no moveable components near the plasma...... describes the two systems and their main components. Section 3 clarifies the impact of design parameters such as beam widths and scattering angle on the CTS measurements. With this in hand, the ITER measurement requirements are translated into constraints on the CTS system designs. An important result...

  10. Collective Thomson scattering of a high power electron cyclotron resonance heating beam in LHD

    DEFF Research Database (Denmark)

    Kubo, S.; Nishiura, M.; Tanaka, K.

    2010-01-01

    Collective Thomson scattering (CTS) system has been constructed at LHD making use of the high power ECRH system in LHD. The necessary features for CTS, high power probing beams and receiving beams, both with well defined Gaussian profile and with the fine controllability, are endowed in the ECRH...... system. The 32 channel radiometer with sharp notch filter at the front end is attached to the ECRH system transmission line as a CTS receiver. The validation of the CTS signal is performed by scanning the scattering volume. A new method to separate the CTS signal from background ECE is developed...

  11. Periodic Thomson scattering diagnostic with 16 spatial channels on ASDEX

    International Nuclear Information System (INIS)

    Meisel, D.; Murmann, H.; Roehr, H.; Steuer, K.H.; Becker, G.; Bosch, H.S.; Brocken, H.; Eberhagen, A.; Fussmann, G.; Gehre, O.; Gernhardt, J.; Gierke, G. v.; Glock, E.; Gruber, O.; Haas, G.; Hofmann, J.; Janeschitz, G.; Karger, F.; Klueber, O.; Kornherr, M.; Lackner, K.; Lenoci, M.; Lisitano, G.; Mast, F.; Mayer, H.M.; McCormick, K.; Mertens, V.; Niedermeyer, H.; Poschenrieder, W.; Rapp, H.; Roth, J.; Schneider, F.; Setzensack, C.; Siller, G.; Soeldner, F.X.; Wagner, F.; Zasche, D.; Izvozchikov, A.; Ryter, F.

    1986-01-01

    The Nd-YAG Periodic Scattering System (PSS) was developped in teamwork with IPF of Stuttgart-University. At first a PSS with only one spatial channel was successfully tested in the ASDEX-Tokamak in 1982. Subsequently an upgraded system with 16 spatial channels was constructed. This new system is capable of measuring Te, Ne-profiles at 17 ms intervals during the entire ASDEX-Tokamak-discharge. The PSS has been working successfully for the last one and a half years as a standard diagnostic method in the ASDEX-Tokamak. This means, that the measurement is being automatically performed during all plasma-discharges. The Te- and Ne-values are stored in the ASDEX-computer and every user has the possibility to get the Te(r, t), Ne(r, t)-data for his own needs. (orig.)

  12. Thomson scattering diagnostic analyses to determine the energetic particle distributions in TFTR. Final report

    International Nuclear Information System (INIS)

    Aamodt, R.E.; Cheung, P.Y.; Russell, D.A.

    1995-01-01

    Lodestar has been an active participant in the low power Collective Thomson Scattering (CTS) diagnostic at TFTR in collaboration with MIT. Extensive studies were conducted regarding the use of gyrotron scattering as a low cost diagnostic for both energetic ions and alpha particles on TFTR. The numerical scattering code has been improved and compared with similar code developed at JET. The authors have participated and assisted in the CTS experiments through onsite visits and have successfully performed most of the data analysis tasks remotely. Through their analysis on the initial data base accumulated, they are able to understand qualitatively the general features of the anomalous large scattered signal, have proposed an explanation for its generation mechanism, and have suggested a potential new use of CTS as an edge diagnostic

  13. Proof-of-principle test of a Thomson scattering alpha particle diagnostic (abstract)

    Science.gov (United States)

    Hutchinson, D. P.; Richards, R. K.; Hunter, H. T.; Bennett, C. A.

    1990-10-01

    A CO2 laser Thomson scattering diagnostic is being developed for the measurement of high-energy alpha particles in a burning plasma. To evaluate the system, a proof-of-principle test is presently in progress. The goal of the experiment is to perform small-angle scattering measurements on a nonburning plasma in the Advanced Toroidal Facility (ATF). In the absence of fusion-product alpha particles, measurements are being made on the smaller scattered signal from the background electrons in the plasma. Preliminary results, indicating receiver calibration and stray light measurements, and calculations of expected scattered power based on measured density and temperature profiles in ATF will be presented. This research was sponsored by Office of Fusion Energy, U. S. DOE, under contract No. DE-AC05-84OR21400 with Martin Marietta Energy Systems, Inc.

  14. Generation of Attosecond X-Ray Pulse through Coherent Relativistic Nonlinear Thomson Scattering

    CERN Document Server

    Lee, K; Jeong, Y U; Lee, B C; Park, S H

    2005-01-01

    In contrast to some recent experimental results, which state that the Nonlinear Thomson Scattered (NTS) radiation is incoherent, a coherent condition under which the scattered radiation of an incident laser pulse by a bunch of electrons can be coherently superposed has been investigated. The Coherent Relativistic Nonlinear Thomson Scattered (C-RNTS) radiation makes it possible utilizing the ultra-short pulse nature of NTS radiation with a bunch of electrons, such as plasma or electron beams. A numerical simulation shows that a 25 attosecond X-ray pulse can be generated by irradiating an ultra-intense laser pulse of 4x10(19) W/cm2 on an ultra-thin solid target of 50 nm thickness, which is commercially available. The coherent condition can be easily extended to an electron beam from accelerators. Different from the solid target, much narrower electron beam is required for the generation of an attosecond pulse. Instead, this condition could be applied for the generation of intense Compton scattered X-rays with a...

  15. Measurement of electron density of the plasma in the Tokamak TCABR, through Thomson scattering diagnostic

    International Nuclear Information System (INIS)

    Jeronimo, Leonardo Cunha

    2013-01-01

    Over the last few years is remarkable, so increasingly evident the need for a new source of energy for mankind. One promising option is through nuclear fusion, where the plasma produced in the reactor can be converted into electrical energy. Therefore, knowing the characteristics of this plasma is very important to control it and understand it so desirable. One of the diagnostic options is called Thomson scattering . This is considered the most reliable method for the determination of important plasma parameters such as temperature and electron density, and may also help in the study and explanation of various internal mechanisms. The great advantage lies in the tact that they consist of a direct measurement and nonperturbative. But it is a diagnosis whose installation and execution is admittedly complex, limiting it only a few laboratories in the fíeld of fusion for the world. Among the main difficulties, wc can highlight the fact that the scattered signal is very small, thus requiring a large increase of the incident power. Moreover, the external physical conditions can cause mechanical vibrations that eliminate or minimize them as much as possible, is a great challenge, considering the optical micrometrically very sensitive and needs involved in the system. This work describes the entire process of installation and operation of Thomson scattering diagnostic in tokamak TCABR and through this diagnosis, we work on results of electron temperature, to finally be able to calculate the electron density of the plasma. (author)

  16. Diagnostic of the Symbiotic Stars Environment by Thomson, Raman and Rayleigh Scattering Processes

    Directory of Open Access Journals (Sweden)

    M. Sekeráš

    2015-02-01

    Full Text Available Symbiotic stars are long-period interacting binaries consisting of a cool giant as the donor star and a white dwarf as the acretor. Due to acretion of the material from the giant’s stellar wind, the white dwarf becomes very hot and luminous. The circumstellar material partially ionized by the hot star, represents an ideal medium for processes of scattering. To investigate the symbiotic nebula we modeled the wide wings of the resonance lines OVI λ1032 Å, λ1038 Å and HeII λ1640 Å emission line in the spectrum of AG Dra, broadened by Thomson scattering. On the other hand, Raman and Rayleigh scattering arise in the neutral part of the circumstellar matter around the giant and provide a powerful tool to probe e.g. the ionization structure of the symbiotic systems and distribution of the neutral hydrogen atoms in the giant’s wind.

  17. Principles of fuel ion ratio measurements in fusion plasmas by collective Thomson scattering

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Nielsen, Stefan Kragh; Bindslev, Henrik

    2011-01-01

    by the signatures of ion cyclotron motion and ion Bernstein waves which appear for scattering geometries with resolved wave vectors near perpendicular to the magnetic field. We investigate the origin and properties of these features in CTS spectra and give estimates of their relative importance for fuel ion ratio......For certain scattering geometries collective Thomson scattering (CTS) measurements are sensitive to the composition of magnetically confined fusion plasmas. CTS therefore holds the potential to become a new diagnostic for measurements of the fuel ion ratio—i.e. the tritium to deuterium density...... ratio. Measurements of the fuel ion ratio will be important for plasma control and machine protection in future experiments with burning fusion plasmas. Here we examine the theoretical basis for fuel ion ratio measurements by CTS. We show that the sensitivity to plasma composition is enhanced...

  18. Design and development of distributed control system for SST-1 Thomson scattering experiment

    Science.gov (United States)

    Chaudhari, V.; Patel, K.; Srivastava, A.; Thomas, J.; kumar, A.

    2013-11-01

    For reliable and uninterrupted operation of Thomson scattering diagnostic, a reliable, simple and distributed control system is developed. The use of Field Programmable Gate Array (FPGA) based stand-alone control system, rugged PXI based timing system, simple digital input-output controller using micro-controller, USB based oscilloscope and Ethernet based data communication for client-server architecture makes the control system to operate in an effective manner. The LabVIEW based software architecture controls and monitors the action in a more simple and transparent manner. The developed control system is modular in terms ofup gradation, flexibility and redundant facility.

  19. Personnel protection during the operation of Thomson scattering laser system on COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Böhm, Petr; Hron, Martin; Kovar, J.; Sova, J.; Zvolanek, M.; Aftanas, Milan; Bílková, Petra; Pánek, Radomír; Walsh, M.J.

    2011-01-01

    Roč. 86, 6-8 (2011), s. 699-702 ISSN 0920-3796. [Symposium on Fusion Technology, SOFT-26/26th./. Porto, 27.09.2010-01.10.2010] R&D Projects: GA ČR GA202/09/1467; GA ČR GD202/08/H057; GA MŠk 7G09042 Institutional research plan: CEZ:AV0Z20430508 Keywords : Tokamak * Thomson scattering * Laser safety * Personnel protection * PLC Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.490, year: 2011 http://www.sciencedirect.com/science/article/pii/S0920379611002432

  20. Fast-ion dynamics in the TEXTOR tokamak measured by collective Thomson scattering

    International Nuclear Information System (INIS)

    Bindslev, H; Nielsen, S K; Porte, L; Hoekzema, J A; Korsholm, S B; Meo, F; Michelsen, P K; Michelsen, S; Oosterbeek, J W; Tsakadze, E L; Westerhof, E; Woskov, P

    2007-01-01

    The dynamics of fast ion populations in the TEXTOR tokamak are measured by collective Thomson scattering of millimetre wave radiation generated by a gyrotron operated at 110 GHz and 100-150 kW. Temporal evolution of the energetic ion velocity distribution at switch on of neutral beam injection (NBI) and the slowdown after switch off of NBI are measured. The turn on phase of the NBI has, furthermore, been measured in plasmas with a range of electron densities and temperatures. All of these measurements are shown to be in good agreement with simple Fokker-Planck modelling. Bulk ion rotation velocity is also measured

  1. Timing and triggering of the Thomson scattering diagnostics on the COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Mikulín, Ondřej; Hron, Martin; Böhm, Petr; Naylor, G.; Bílková, Petra; Janky, Filip; Salášek, J.; Pánek, Radomír

    2014-01-01

    Roč. 89, č. 5 (2014), s. 693-697 ISSN 0920-3796. [The 9th Technical Meeting on Control, Data Acquisition, and Remote Participation for Fusion Research/9./. Hefei, 06.05.2013-10.05.2013] R&D Projects: GA MŠk 7G10072; GA MŠk(CZ) LM2011021; GA ČR GAP205/11/2470 Institutional support: RVO:61389021 Keywords : Tokamak * Timing and triggering * FPGA * Real-time control * Diagnostics control * Thomson scattering Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.152, year: 2014 http://www.sciencedirect.com/science/article/pii/S0920379614002105#

  2. Ultrashort hard x-ray pulses generated by 90 degrees Thomson scattering

    International Nuclear Information System (INIS)

    Chin, A.H.; Schoenlein, R.W.; Glover, T.E.

    1997-01-01

    Ultrashort x-ray pulses permit observation of fast structural dynamics in a variety of condensed matter systems. The authors have generated 300 femtosecond, 30 keV x-ray pulses by 90 degrees Thomson scattering between femtosecond laser pulses and relativistic electrons. The x-ray and laser pulses are synchronized on a femtosecond time scale, an important prerequisite for ultrafast pump-probe spectroscopy. Analysis of the x-ray beam properties also allows for electron bunch characterization on a femtosecond time scale

  3. LIGHT SOURCE: A simulation study of Tsinghua Thomson scattering X-ray source

    Science.gov (United States)

    Tang, Chuan-Xiang; Li, Ren-Kai; Huang, Wen-Hui; Chen, Huai-Bi; Du, Ying-Chao; Du, Qiang; Du, Tai-Bin; He, Xiao-Zhong; Hua, Jian-Fei; Lin, Yu-Zhen; Qian, Hou-Jun; Shi, Jia-Ru; Xiang, Dao; Yan, Li-Xin; Yu, Pei-Cheng

    2009-06-01

    Thomson scattering X-ray sources are compact and affordable facilities that produce short duration, high brightness X-ray pulses enabling new experimental capacities in ultra-fast science studies, and also medical and industrial applications. Such a facility has been built at the Accelerator Laboratory of Tsinghua University, and upgrade is in progress. In this paper, we present a proposed layout of the upgrade with design parameters by simulation, aiming at high X-ray pulses flux and brightness, and also enabling advanced dynamics studies and applications of the electron beam. Design and construction status of main subsystems are also presented.

  4. Edge Thomson scattering diagnostic on COMPASS tokamak: Installation, calibration,operation, improvements

    Czech Academy of Sciences Publication Activity Database

    Böhm, Petr; Aftanas, Milan; Bílková, Petra; Štefániková, Estera; Mikulín, Ondřej; Melich, Radek; Janky, Filip; Havlíček, Josef; Šesták, David; Weinzettl, Vladimír; Stöckel, Jan; Hron, Martin; Pánek, Radomír; Scannell, R.; Frassinetti, L.; Fassina, A.; Naylor, G.; Walsh, M.J.

    2014-01-01

    Roč. 85, č. 11 (2014), 11E431-11E431 ISSN 0034-6748. [Topical Conference on High- Temperature Plasma Diagnostics/20./. Atlanta, Georgia, 01.06.2014-05.06.2014] R&D Projects: GA MŠk(CZ) LM2011021; GA ČR(CZ) GA14-35260S Institutional support: RVO:61389021 Keywords : plasma * tokamak * pedestal * Thomson scattering * diagnostic Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.614, year: 2014 http://scitation.aip.org/content/aip/journal/rsi/85/11/10.1063/1.4893995

  5. Fitting of the Thomson scattering density and temperature profiles on the COMPASS tokamak

    International Nuclear Information System (INIS)

    Stefanikova, E.; Peterka, M.; Bohm, P.; Bilkova, P.; Aftanas, M.; Urban, J.; Hron, M.; Panek, R.; Sos, M.

    2016-01-01

    A new technique for fitting the full radial profiles of electron density and temperature obtained by the Thomson scattering diagnostic in H-mode discharges on the COMPASS tokamak is described. The technique combines the conventionally used modified hyperbolic tangent function for the edge transport barrier (pedestal) fitting and a modification of a Gaussian function for fitting the core plasma. Low number of parameters of this combined function and their straightforward interpretability and controllability provide a robust method for obtaining physically reasonable profile fits. Deconvolution with the diagnostic instrument function is applied on the profile fit, taking into account the dependence on the actual magnetic configuration.

  6. Ultrashort hard x-ray pulses generated by 90 degrees Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Chin, A.H. [Univ. of California, Berkeley, CA (United States); Schoenlein, R.W.; Glover, T.E. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    Ultrashort x-ray pulses permit observation of fast structural dynamics in a variety of condensed matter systems. The authors have generated 300 femtosecond, 30 keV x-ray pulses by 90 degrees Thomson scattering between femtosecond laser pulses and relativistic electrons. The x-ray and laser pulses are synchronized on a femtosecond time scale, an important prerequisite for ultrafast pump-probe spectroscopy. Analysis of the x-ray beam properties also allows for electron bunch characterization on a femtosecond time scale.

  7. Elevation angle alignment of quasi optical receiver mirrors of collective Thomson scattering diagnostic by sawtooth measurements

    DEFF Research Database (Denmark)

    Moseev, D.; Meo, Fernando; Korsholm, Søren Bang

    2012-01-01

    Localized measurements of the fast ion velocity distribution function and the plasma composition measurements are of significant interest for the fusion community. Collective Thomson scattering (CTS) diagnostics allow such measurements with spatial and temporal resolution. Localized measurements...... require a good alignment of the optical path in the transmission line. Monitoring the alignment during the experiment greatly benefits the confidence in the CTS measurements. An in situ technique for the assessment of the elevation angle alignment of the receiver is developed. Using the CTS diagnostic...

  8. Collective Thomson scattering energetic particle diagnostic in high performance tokamaks. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, P.Y.; Aamodt, R.E.; Russell, D.A.

    1997-07-08

    This report summarizes the work performed under DOE grant DE-FG03-95ER54334. Lodestar was an active participant in the low power Collective Thomson Scattering (CTS) diagnostic experiment at TFTR in collaboration with MIT. A simple and effective fitting technique was developed to extract key parameters from the scattered data. Utilizing this new technique, the concept of lower hybrid resonance scattering was adapted for a feasibility study of a low/medium power collective scattering diagnostic for ITER. The implementation and the testing of such a technique for actual parameter extraction using TFTR data, however, was severely limited due to experimental and instrumentation complications. Based on the studies the authors have performed up to date, it is believed that a combination of non-physics related effects such as multiple wall reflection of incident signal and spectral impurity problem o the gyrotron can account for the anomalous signal strength. A collaborative effort with GA was initiated and a feasibility study of developing and implementing a collective thomson scattering (CTS) diagnostic for the detection of energetic particles at DIII-D was completed. Specifically, the process of selecting an optimum receiver location for the diagnostic is discussed in detailed. Results presented here include detailed signal to noise calculations and ray-tracing studies. Critical physics issues and selection criteria are discussed and a procedure to detect anisotropic energetic ion temperatures is also outlined. Favorable results, obtained in the feasibility study, indicate that it should be possible to develop and implement a CTS diagnostic at DIII-D.

  9. Conceptual Design Studies of the KSTAR Bay-Nm Cassette and Thomson Scattering Optics

    Energy Technology Data Exchange (ETDEWEB)

    Feder, R.; Ellis, R.; Johnson, D.; Park, H.; Lee, H. G.

    2005-09-26

    A Multi-Channel Thomson Scattering System viewing the edge and core of the KSTAR plasma will be installed at the mid-plane port Bay-N. An engineering design study was undertaken at PPPL in collaboration with the Korea Basic Science Institute (KBSI) to determine the optimal optics and cassette design. Design criteria included environmental, mechanical and optical factors. All of the optical design options have common design features; the Thomson Scattering laser, an in-vacuum shutter, a quartz heat shield and primary vacuum window, a set of optical elements and a fiber optic bundle. Neutron radiation damage was a major factor in the choice of competing lens-based and mirror-based optical designs. Both the mirror based design and the lens design are constrained by physical limits of the Bay-N cassette and interference with the Bay-N micro-wave launcher. The cassette will contain the optics and a rail system for maintenance of the optics.

  10. Computer data-acquisition and control system for Thomson-scattering measurements

    International Nuclear Information System (INIS)

    Stewart, K.A.; Foskett, R.D.; Kindsfather, R.R.; Lazarus, E.A.; Thomas, C.E.

    1983-03-01

    The Thomson-Scattering Diagnostic System (SCATPAK II) used to measure the electron temperature and density in the Impurity Study Experiment is interfaced to a Perkin-Elmer 8/32 computer that operates under the OS/32 operating system. The calibration, alignment, and operation of this diagnostic are all under computer control. Data acquired from 106 photomultiplier tubes installed on 15 spectrometers are transmitted to the computer by eighteen 12-channel, analog-to-digital integrators along a CAMAC serial highway. With each laser pulse, 212 channels of data are acquired: 106 channels of signal plus background and 106 channels of background only. Extensive use of CAMAC instrumentation enables large amounts of data to be acquired and control processes to be performed in a time-dependent environment. The Thomson-scattering computer system currently operates in three modes: user interaction and control, data acquisition and transmission, and data analysis. This paper discusses the development and implementation of this system as well as data storage and retrieval

  11. Material Assessment for ITER's Collective Thomson Scattering first mirror

    Energy Technology Data Exchange (ETDEWEB)

    Santos, R.; Policarpo, H.; Goncalves, B.; Varela, P. [Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade de Lisboa, 1049-001 Lisboa (Portugal); Nonboel, E.; Klinkby, E.; Lauritzen, B. [Center for Nuclear Technologies, Technical University of Denmark (Denmark); Romanets, Y.; Luis, R.; Vaz, P. [Centro de Ciencias e Tecnologias Nucleares, Instituto Superior Tecnico, Universidade de Lisboa (Portugal)

    2015-07-01

    The International Thermonuclear Energy Reactor (ITER) Collective Thomson Scattering (CTS) system is a diagnostic instrument that measures plasma density and velocity through Thomson scattering of microwave radiation. Some of the key components of the CTS are quasi-optical mirrors that are used to produce astigmatic beam patterns, which have impact on the strength and spatial resolution of the diagnostic signal. The mirrors are exposed to neutron radiation, which may alter the quality of the signal received. In this work, three different materials (molybdenum (Mo), stainless steel 316 (SS-316) and tungsten (W)) are considered for the first mirror of the CTS. The objective is to access which of the material studied are best suited for this mirror, considering different neutron radiation loads simulated scenarios defined by ITER, based on the resultant stresses and temperature distributions. For it, the neutron irradiation, and subsequent heat-load on the mirrors are simulated using the Monte Carlo N-Particle (MCNP) code. Based on the MCNP heat-load results, transient thermal-structural Finite Element Analysis (FEA) of the mirror over a 400 s discharge, with and without cooling on the rear side, are conducted using in commercial FEA software ANSYS. Results show that of the tested materials Mo and W are the most suitable material for this application. Even though, this study does not yet consider the variation of the material properties with temperature, it presents a quick initial satisfactory assessment that may be considered in subsequent and more complex analysis. (authors)

  12. Conceptual Design Studies of the KSTAR Bay-Nm Cassette and Thomson Scattering Optics

    International Nuclear Information System (INIS)

    Feder, R.; Ellis, R.; Johnson, D.; Park, H.; Lee, H.G.

    2005-01-01

    A Multi-Channel Thomson Scattering System viewing the edge and core of the KSTAR plasma will be installed at the mid-plane port Bay-N. An engineering design study was undertaken at PPPL in collaboration with the Korea Basic Science Institute (KBSI) to determine the optimal optics and cassette design. Design criteria included environmental, mechanical and optical factors. All of the optical design options have common design features; the Thomson Scattering laser, an in-vacuum shutter, a quartz heat shield and primary vacuum window, a set of optical elements and a fiber optic bundle. Neutron radiation damage was a major factor in the choice of competing lens-based and mirror-based optical designs. Both the mirror based design and the lens design are constrained by physical limits of the Bay-N cassette and interference with the Bay-N micro-wave launcher. The cassette will contain the optics and a rail system for maintenance of the optics

  13. Solution for a window coating problem developed in the JT-60U Thomson scattering system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Hidetoshi; Naito, Osamu; Hatae, Takaki; Nagashima, Akira [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1996-11-01

    For an exact measurement of fusion plasmas with higher electron temperature, the following two methods which can solve a window coating problem were developed in the JT-60U Thomson scattering system. One is an in situ monitoring method which can infer a window transmission with sufficient precision from a known attenuation of the deposited film. The other is an in situ window cleaning method which removes the film on the basis of a laser blow-off technique. As the results of the extensive investigations, the existence of chromatic upper limit has been found in the recovered transmission after the laser blow-off cleaning, however, which gives systematic errors only of less than 3% to the apparent measurement for both electron density and temperature at 10 keV or less. The attenuation itself was unchanged before and after the laser blow-off cleaning. So the first method can be also applicable to the window after the laser blow-off cleaning. A complementary use of both the methods against the window coating problem can be expected to provide the Thomson scattering measurement of high T{sub e} plasmas with durable reliability and sufficient precision in the present tokamaks and also the ITER. (author)

  14. Electron temperature measurements by the use of multi-pass Thomson scattering system in GAMMA 10/PDX

    Science.gov (United States)

    Yoshikawa, M.; Ohta, K.; Wang, X.; Morishita, M.; Chikatsu, M.; Shima, Y.; Kohagura, J.; Yasuhara, R.; Sakamoto, M.; Nakashima, Y.; Imai, T.; Ichimura, M.; Yamada, I.; Funaba, H.; Kawataha, K.; Minami, T.

    2015-08-01

    A multi-pass (MP) Thomson scattering (TS) system modeled on the GAMMA 10/PDX TS system was constructed for enhancing the Thomson scattered signals. The MPTS system has a polarization-based configuration with an image relaying system. The former MPTS system in GAMMA 10/PDX can measure only four passing signals. We changed the larger aperture polarization control device for improving the MP laser confinement and obtaining the over four passing MPTS signals. The integrated MPTS signals increased about 1.2 times larger than that in the former system.

  15. Precision of ion temperature measurements in a tokamak plasma using collective Thomson scattering: a numerical study

    International Nuclear Information System (INIS)

    Krug, P.A.

    1989-08-01

    A numerical simulation has been performed to investigate the precision of a T i -measurement of a tokamak plasma via collective Thomson scattering at 385 μm. The study is based on a parameter and data set referring to an experiment that has been carried out at the TCA tokamak using a pulsed D 2 O laser and a heterodyne receiver system. Apart from limitations due to the signal-to-noise ratio of the detection system, we investigate the influence of uncertainties in various plasma parameters required for the T i -evaluation from a scattered spectrum. In the experiment typical relative errors of ± 25% have been already been obtained, but careful optimization of the system, taking into account the results of this study, and further technical improvements should allow to reduce this limit to about ±10% for the plasma conditions considered. (author) 17 figs., 1 tab., 6 refs

  16. Impact of ICRH on the measurement of fusion alphas by collective Thomson scattering in ITER

    DEFF Research Database (Denmark)

    Salewski, Mirko; Eriksson, L.-G.; Bindslev, Henrik

    2009-01-01

    , corresponding to an off-axis resonance. The sensitivities of the results to the He-3 concentration (0.1-4%) and the heating power (20-40 MW) are considered. Fusion born alphas dominate the total CTS signal for large Doppler shifts of the scattered radiation. The tritons generate a negligible fraction......Collective Thomson scattering (CTS) has been proposed for measuring the phase space distributions of confined fast ion populations in ITER plasmas. This study determines the impact of fast ions accelerated by ion cyclotron resonance heating (ICRH) on the ability of CTS to diagnose fusion alphas...... perpendicular velocities, it may be difficult to draw conclusions about the physics of alpha particles alone by CTS. With this exception, the CTS diagnostic can reveal the physics of the fusion alphas in ITER even under the presence of fast ions due to ICRH....

  17. Investigation of first mirror heating for the collective Thomson scattering diagnostic in ITER

    DEFF Research Database (Denmark)

    Salewski, Mirko; Meo, Fernando; Bindslev, Henrik

    2008-01-01

    Collective Thomson scattering (CTS) has the capabilities to measure phase space densities of fast ion populations in ITER resolved in configuration space, in velocity space, and in time. In the CTS system proposed for ITER, probing radiation at 60 GHz generated by two 1 MW gyrotrons is scattered...... in the plasma and collected by arrays of receivers. The transmission lines from the gyrotrons to the plasma and from the plasma to the receivers contain several quasioptical mirrors among other components. These are designed to produce astigmatic beam patterns in the plasma where the beam shapes will have...... a direct impact on the signal strength of the diagnostic, the spatial resolution, and the robustness of probe and receiver beam overlap against density excursions. The first mirror has a line of sight to the plasma and is thus exposed to severe neutron streaming. The present neutronics and thermomechanical...

  18. The Thomson scattering experiment pulsed by CO2 laser in FT

    International Nuclear Information System (INIS)

    Bartolini, L.; Fornetti, G.; Nardi, M.; Occhionero, G.; Ferri de Collibus, M.

    1987-01-01

    An experiment carried out to measure the plasma ion temperature Tsub(i) in the tokamak FT in Frascati by Collective Thomson Scattering. A tandem laser system generates two single mode beams (10.6μ) one of which is pulsed and amplified up to levels of 5 MW, 1μs and actively frequency locked to a second continuous wave low pressure CO 2 laser. The pulse beam crosses the plasma and the forward scattered light is collected at angles between 1 degrees centigrade and 1.6 degrees centigrade. An heterodyne technique in which the c.w. beam is the local oscillator is used to measure the Doppler enlarged spectral density of the signal. The experimental apparatus is described and the results are reported and discussed

  19. Design and performance of the collective Thomson scattering receiver at ASDEX Upgrade

    DEFF Research Database (Denmark)

    Furtula, Vedran; Salewski, Mirko; Leipold, Frank

    2012-01-01

    is divided into 50 IF channels tightly spaced in frequency space. The channels are terminated by square-law detector diodes that convert the signal power into DC voltages. We present measurements of the transmission characteristics and performance of the main receiver components operating at mm-wave......Here we present the design of the fast-ion collective Thomson scattering receiver for millimeter wave radiation installed at ASDEX Upgrade, a tokamak for fusion plasma experiments. The receiver can detect spectral power densities of a few eV against the electron cyclotron emission background...... on the order of 100 eV under presence of gyrotron stray radiation that is several orders of magnitude stronger than the signal to be detected. The receiver down converts the frequencies of scattered radiation (100-110 GHz) to intermediate frequencies (IF) (4.5-14.5 GHz) by heterodyning. The IF signal...

  20. A Concept for Measuring Electron Distribution Functions Using Collective Thomson Scattering

    Science.gov (United States)

    Milder, A. L.; Froula, D. H.

    2017-10-01

    A.B. Langdon proposed that stable non-Maxwellian distribution functions are realized in coronal inertial confinement fusion plasmas via inverse bremsstrahlung heating. For Zvosc2 Zvosc2 vth2 > 1 , vth2 > 1 , the inverse bremsstrahlung heating rate is sufficiently fast to compete with electron-electron collisions. This process preferentially heats the subthermal electrons leading to super-Gaussian distribution functions. A method to identify the super-Gaussian order of the distribution functions in these plasmas using collective Thomson scattering will be proposed. By measuring the collective Thomson spectra over a range of angles the density, temperature and super-Gaussian order can be determined. This is accomplished by fitting non-Maxwellian distribution data with a super-Gaussian model; in order to match the density and electron temperature to within 10%, the super-Gaussian order must be varied. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  1. Preliminary investigation of an atmospheric microplasma using Raman and Thomson laser scattering

    Science.gov (United States)

    Sommers, Bradley; Adams, Steven

    2014-10-01

    A triple grating spectrometer system has been coupled with an ultraviolet laser at 266 nm for the purpose of investigating Rayleigh, Raman, and Thomson scattering within atmospheric plasma sources. Such laser interactions present a non-invasive diagnostic to investigate small scale atmospheric plasma sources, which have recently garnered interest for applications in remote optical sensing, materials processing, and environmental decontamination. In this work, the laser scatter and temperature relationship were calibrated with a heated nitrogen cell held at atmospheric pressure while subsequent scattering measurements were made in atmospheric discharges composed of nitrogen and air. An adjustable electrode configuration and dc circuit were assembled to produce a microdischarge operating in normal glow mode, thus providing a non-thermal plasma in which the translational, rotational, vibrational and electron temperatures are not in equilibrium. Preliminary results include measurements of these temperatures, which were calculated by fitting simulated scattering spectra to the experimental data obtained using the triple grating spectrometer. Measured temperatures were also compared with those obtained using standard optical emission spectroscopy methods. Special thanks to the NRC Research Associateship Program.

  2. Improved Collective Thomson Scattering measurements of fast ions at ASDEX Upgrade

    DEFF Research Database (Denmark)

    Rasmussen, Jesper; Nielsen, Stefan Kragh; Stejner Pedersen, Morten

    2014-01-01

    Scattering (CTS) is well suited for reactor conditions and offers such an opportunity by providing measurements of the confined fast-ion distribution function resolved in space, time and 1D velocity space. We currently operate a CTS system at ASDEX Upgrade using a gyrotron which generates probing radiation......Understanding the behaviour of the confined fast ions is important in both current and future fusion experiments. These ions play a key role in heating the plasma and will be crucial for achieving conditions for burning plasma in next-step fusion devices. Microwave-based Collective Thomson...... at 105 GHz. A new setup using two independent receiver systems has enabled improved subtraction of the background signal, and hence the first accurate characterization of fast-ion properties. Here we review this new dual-receiver CTS setup and present results on fast-ion measurements based...

  3. Thomson scattering measurement of a collimated plasma jet generated by a high-power laser system

    Science.gov (United States)

    Ishikawa, T.; Sakawa, Y.; Morita, T.; Yamaura, Y.; Kuramitsu, Y.; Moritaka, T.; Sano, T.; Shimoda, R.; Tomita, K.; Uchino, K.; Matsukiyo, S.; Mizuta, A.; Ohnishi, N.; Crowston, R.; Woolsey, N.; Doyle, H.; Gregori, G.; Koenig, M.; Michaut, C.; Pelka, A.; Yuan, D.; Li, Y.; Zhang, K.; Zhong, J.; Wang, F.; Takabe, H.

    2016-03-01

    One of the important and interesting problems in astrophysics and plasma physics is collimation of plasma jets. The collimation mechanism, which causes a plasma flow to propagate a long distance, has not been understood in detail. We have been investigating a model experiment to simulate astrophysical plasma jets with an external magnetic field [Nishio et al., EPJ. Web of Conferences 59, 15005 (2013)]. The experiment was performed by using Gekko XII HIPER laser system at Institute of Laser Engineering, Osaka University. We shot CH plane targets (3 mm × 3 mm × 10 μm) and observed rear-side plasma flows. A collimated plasma flow or plasma jet was generated by separating focal spots of laser beams. In this report, we measured plasma jet structure without an external magnetic field with shadowgraphy, and simultaneously measured the local parameters of the plasma jet, i.e., electron density, electron and ion temperatures, charge state, and drift velocity, with collective Thomson scattering.

  4. Thomson scattering measurements of ion interpenetration in cylindrically converging, supersonic magnetized plasma flows

    Science.gov (United States)

    Swadling, George

    2015-11-01

    Ion interpenetration driven by high velocity plasma collisions is an important phenomenon in high energy density environments such as the interiors of ICF vacuum hohlraums and fast z-pinches. The presence of magnetic fields frozen into these colliding flows further complicates the interaction dynamics. This talk focuses on an experimental investigation of ion interpenetration in collisions between cylindrically convergent, supersonic, magnetized flows (M ~10, Vflow ~ 100km/s, ni ~ 1017cm-3) . The flows used in this study were plasma ablation streams produced by tungsten wire array z-pinches, driven by the 1.4MA, 240ns Magpie facility at Imperial College, and diagnosed using a combination of optical Thomson scattering, Faraday rotation and interferometry. Optical Thomson scattering (TS) provides time-resolved measurements of local flow velocity and plasma temperature across multiple (7 to 14) spatial positions. TS spectra are recorded simultaneously from multiple directions with respect to the probing beam, resulting in separate measurements of the rates of transverse diffusion and slowing-down of the ion velocity distribution. The measurements demonstrate flow interpenetration through the array axis at early time, and also show an axial deflection of the ions towards the anode. This deflection is induced by a toroidal magnetic field (~ 10T), frozen into the plasma that accumulates near the axis. Measurements obtained later in time show a change in the dynamics of the stream interactions, transitioning towards a collisional, shock-like interaction of the streams, and rapid radial collapse of the magnetized plasma column. The quantitative nature of the spatial profiles of the density, flow velocities and ion temperatures measured in these experiments will allow detailed verification of MHD and PIC codes used by the HEDP community. Work Supported by EPSRC (Grant No. EP/G001324/1), DOE (Cooperative Agreement Nos. DE-F03-02NA00057 & DE-SC-0001063) & Sandia National

  5. A pulse-burst laser system for Thomson scattering on NSTX-U

    Science.gov (United States)

    Den Hartog, D. J.; Borchardt, M. T.; Holly, D. J.; Diallo, A.; LeBlanc, B.

    2017-10-01

    A pulse-burst laser system has been built for Thomson scattering on NSTX-U, and is currently being integrated into the NSTX-U Thomson scattering diagnostic system. The laser will be operated in three distinct modes. The base mode is continuous 30 Hz rep rate, and is the standard operating mode of the laser. The base mode will be interrupted to produce a "slow burst" (specified 1 kHz rep rate for 50 ms) or a "fast burst" (specified 10 kHz rep rate for 5 ms). The combination of base mode→ interruption→ burst mode is new and has not been implemented on any previous pulse-burst laser system. Laser pulsing is halted for a set period (~ 1 minute) following a burst to allow the YAG rods to cool; this type of operation is called a heat-capacity laser. The laser is Nd:YAG operated at 1064 nm, q-switched to produce >= 1.5 J pulses with ~ 20 ns FWHM. It is flashlamp pumped, with dual-rod oscillator (9 mm) and dual-rod amplifier (12 mm). Variable pulsewidth drive of the flashlamps is accomplished by IGBT (insulated gate bipolar transistor) switching of electrolytic capacitor banks. Direct control of the laser Pockels cell drive enables optimal pulse energy extraction. The laser system has demonstrated compliance with all specifications, and is capable of exceeding design specifications by significant margins, e.g., higher rep rates for longer burst periods. Burst operation of this laser system will be used to capture fast time evolution of the electron temperature and density profiles during events such as ELMs, the L-H transition, and various MHD modes.

  6. Development of high-efficiency laser Thomson scattering measurement system for the investigation of EEDF in surface wave plasma

    International Nuclear Information System (INIS)

    Aramaki, M.; Kobayashi, J.; Kono, A.; Stamate, E.; Sugai, H.

    2006-01-01

    A high-efficiency multichannel Thomson scattering measurement system was developed as a tool for studying the electron heating mechanisms in a surface wave plasma. By improving the output power and repetition rate of the Nd:YAG laser, an F-number of spectrograph, and a quantum efficiency of ICCD camera, the overall Thomson signal collection efficiency per unit measurement time has been improved by a factor larger than 40 in comparison with the previous measurement system developed by the authors. The one-dimensional electron velocity distribution functions were measured in the vicinity of the dielectric window of a surface wave plasma

  7. Thomson-scattering study of the subharmonic decay of ion-acoustic waves driven by the Brillouin instability

    International Nuclear Information System (INIS)

    Bandulet, H.C.; Labaune, C.; Lewis, K.; Depierreux, S.

    2004-01-01

    Thomson scattering (TS) has been used to investigate the two-ion decay instability of ion acoustic waves generated by stimulated Brillouin scattering in an underdense CH plasma. Two complementary TS diagnostics, spectrally and spatially resolved, demonstrate the occurrence of the subharmonic decay of the primary ion acoustic wave into two secondary waves. The study of the laser intensity dependence shows that the secondary ion acoustic waves are correlated with the SBS reflectivity saturation, at a level of a few percent

  8. Experimental considerations concerning the velocity measurement of the relativistic electron beam in a gyrotron by means of Thomson scattering

    International Nuclear Information System (INIS)

    Siegrist, M.R.; Soumagne, G.; Tran, M.Q.

    1992-11-01

    The feasibility of Thomson scattering to determine the beam velocity in a gyrotron has been analyzed and preliminary experiments to implement such a system on our 100 GHz quasi-optical gyrotron are reported. Although the project had to be abandoned due to technical problems, the conclusions are that for the 90 o scattering arrangement discussed it should be possible to determine at least one velocity component with an acceptable signal-to-noise ratio. (author) 11 figs., 10 refs

  9. Equation of state measurements of shocked carbon foam using x-ray Thomson scattering

    Science.gov (United States)

    Belancourt, Patrick; Keiter, Paul; Drake, Paul; Theobald, Wolfgang; Hu, Suxing; Regan, Sean; Kozlowski, Pawel

    2017-10-01

    Simulating experiments of foams under high-energy-density physics (HEDP) conditions have been challenging due to the uncertainty of the equation of state (EOS) of foams in this regime. This motivated a recent experiment on the OMEGA EP laser system to measure the EOS of shocked 150 mg/cc carbonized resorcinol formaldehyde (CRF) foam. One OMEGA EP beam drives a shock into the CRF foam package, while the remaining three beams are used to create a nickel-He-alpha, x-ray probe. The x-ray probe penetrates the shocked foam and the imaging x-ray Thomson spectrometer (IXTS) measures the scattered x-rays from the probe. The IXTS spectrally resolves the scattered x-ray beam while imaging in 1-D. This results in a temperature and ionization measurement at the shock front from the scattered x-ray spectrum and a density measurement from the imaging component. Preliminary results from this experiment will be shown. This work is funded by the U.S. Department of Energy, through the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, Grant Number DE-NA0002956, and through the Laboratory for Laser Energetics, University of Rochester by the NNSA/OICF under Cooperative Agreement No. DE-NA0001944.

  10. Development of a Thomson scattering diagnostic for the Caltech jet-target experiment

    Science.gov (United States)

    Seo, Byong Hoon; Greig, Amelia; Bellan, Paul

    2016-10-01

    A Thomson scattering diagnostic is being developed for studying the Caltech jet-target impact experiment. This experiment has a high-speed MHD-driven jet impact a dense, high-mass target cloud. The compression of the jet upon impact simulates the compression of an imploding liner. A preliminary bench top system consisting of a low power laser, lenses, a beam rotator, a monochromator, and a PMT is being used for measuring the Rayleigh and eventually Raman scattering signals from atmospheric pressure N2 and O2. The laser is modulated at 500 Hz to 1 kHz and lock-in techniques are used to recover the low-amplitude signal. For the actual pulsed plasma experiment, the low-power laser will be replaced by a high power Nd:YAG laser. The detector will consist of a double monochromator consisting of two single monochromators separated by a mask in the focal plane to block Rayleigh scattered light; detection will be by an intensified, gated camera. The diagnostic will be used to study the compression and heating that occurs when the jet plasma collides with a dense, high mass target cloud. Supported by USDOE Grant DE-AR0000565.

  11. Improvements, upgrades, and plans for Thomson scattering on DIII-D

    Science.gov (United States)

    Carlstrom, T. N.; Du, D.; Glass, F.; Liu, C.; Watkins, M.; McLean, A. G.

    2016-10-01

    The Thomson scattering diagnostic on DIII-D consists of 3 beam lines that probe vertically, horizontally, and in the divertor region of the tokamak, with 54 spatial locations, edge spatial resolution down to 5 mm, and 10 Nd:YAG lasers. In its 25-year history, the collection lens optics and interference filters degraded and have been replaced, restoring previous performance. In addition, improved calibrations and detector temperature control (+/- 0.1 C) have reduced systematic errors. Cross calibration with the CO2 interferometer and ECE cut-off have improved the density calibration. Improvements to the beam line and lasers have increased the laser energy delivered to the scattering volume in the plasma. Future plans include moving the divertor system to measure regions of high triangularity using in-vessel mirrors to redirect the laser beam; adding a wide angle lens to the horizontal system to view the entire plasma radius near the plasma mid plane; and reversing the direction of the laser beam on the horizontal system to reduce the scattering angle and compressing the spectrum in wavelength space so that higher central Te measurements (<5 KeV) can be made with improved accuracy. Work supported by the US DOE under DE-FC02-04ER54698 and by LLNL under DE-AC52-07NA27344.

  12. The upgrade of the Thomson scattering system for measurement on the C-2/C-2U devices

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, K.; Schindler, T.; Kinley, J.; Deng, B.; Thompson, M. C. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States)

    2016-11-15

    The C-2/C-2U Thomson scattering system has been substantially upgraded during the latter phase of C-2/C-2U program. A Rayleigh channel has been added to each of the three polychromators of the C-2/C-2U Thomson scattering system. Onsite spectral calibration has been applied to avoid the issue of different channel responses at different spots on the photomultiplier tube surface. With the added Rayleigh channel, the absolute intensity response of the system is calibrated with Rayleigh scattering in argon gas from 0.1 to 4 Torr, where the Rayleigh scattering signal is comparable to the Thomson scattering signal at electron densities from 1 × 10{sup 13} to 4 × 10{sup 14} cm{sup −3}. A new signal processing algorithm, using a maximum likelihood method and including detailed analysis of different noise contributions within the system, has been developed to obtain electron temperature and density profiles. The system setup, spectral and intensity calibration procedure and its outcome, data analysis, and the results of electron temperature/density profile measurements will be presented.

  13. Measurements of Relativistic Effects in Collective Thomson Scattering at Electron Temperatures less than 1 keV

    Energy Technology Data Exchange (ETDEWEB)

    Ross, James Steven [Univ. of California, San Diego, CA (United States)

    2010-01-01

    Simultaneous scattering from electron-plasma waves and ion-acoustic waves is used to measure local laser-produced plasma parameters with high spatiotemporal resolution including electron temperature and density, average charge state, plasma flow velocity, and ion temperature. In addition, the first measurements of relativistic modifications in the collective Thomson scattering spectrum from thermal electron-plasma fluctuations are presented [1]. Due to the high phase velocity of electron-plasma fluctuations, relativistic effects are important even at low electron temperatures (Te < 1 keV). These effects have been observed experimentally and agree well with a relativistic treatment of the Thomson scattering form factor [2]. The results are important for the interpretation of scattering measurements from laser produced plasmas. Thomson scattering measurements are used to characterize the hydrodynamics of a gas jet plasma which is the foundation for a broad series of laser-plasma interaction studies [3, 4, 5, 6]. The temporal evolution of the electron temperature, density and ion temperature are measured. The measured electron density evolution shows excellent agreement with a simple adiabatic expansion model. The effects of high temperatures on coupling to hohlraum targets is discussed [7]. A peak electron temperature of 12 keV at a density of 4.7 × 1020cm-3 are measured 200 μm outside the laser entrance hole using a two-color Thomson scattering method we developed in gas jet plasmas [8]. These measurements are used to assess laser-plasma interactions that reduce laser hohlraum coupling and can significantly reduce the hohlraum radiation temperature.

  14. Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic.

    Science.gov (United States)

    Kubala, S Z; Borchardt, M T; Den Hartog, D J; Holly, D J; Jacobson, C M; Morton, L A; Young, W C

    2016-11-01

    The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV-5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz-25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.

  15. Thomson scattering laser-electron X-ray source for reduction of patient radiation dose in interventional coronary angiography

    Science.gov (United States)

    Artyukov, I. A.; Dyachkov, N. V.; Feshchenko, R. M.; Polunina, A. V.; Popov, N. L.; Shvedunov, V. I.; Vinogradov, A. V.

    2017-05-01

    It was medical applications that stimulated F. Carrol in the early 1990s to start the research of on relativistic Thomson scattering X-ray sources, as a part of the infrastructure of the future society. The possibility to use such a source in interventional cardiology is discussed in this paper. The replacement of X-ray tube by relativistic Thomson scattering Xray source is predicted to lower the patient radiation dose by a factor of 3 while image quality remains the same. The required general characteristics of accelerator and laser units are found. They can be reached by existing technology. A semiempirical method for simulation of medical and technical parameters of interventional coronary angiography systems is suggested.

  16. High time resolved electron temperature measurements by using the multi-pass Thomson scattering system in GAMMA 10/PDX

    Science.gov (United States)

    Yoshikawa, Masayuki; Yasuhara, Ryo; Ohta, Koichi; Chikatsu, Masayuki; Shima, Yoriko; Kohagura, Junko; Sakamoto, Mizuki; Nakashima, Yousuke; Imai, Tsuyoshi; Ichimura, Makoto; Yamada, Ichihiro; Funaba, Hisamichi; Minami, Takashi

    2016-11-01

    High time resolved electron temperature measurements are useful for fluctuation study. A multi-pass Thomson scattering (MPTS) system is proposed for the improvement of both increasing the TS signal intensity and time resolution. The MPTS system in GAMMA 10/PDX has been constructed for enhancing the Thomson scattered signals for the improvement of measurement accuracy. The MPTS system has a polarization-based configuration with an image relaying system. We optimized the image relaying optics for improving the multi-pass laser confinement and obtaining the stable MPTS signals over ten passing TS signals. The integrated MPTS signals increased about five times larger than that in the single pass system. Finally, time dependent electron temperatures were obtained in MHz sampling.

  17. Two-pulse Thomson scattering system for measurements of fast fluctuations of electron density in multimirror trap GOL-3

    Science.gov (United States)

    Popov, S. S.; Burdakov, A. V.; Ivantsivskiy, M. V.; Kasatov, A. A.; Polosatkin, S. V.; Postupaev, V. V.; Vyacheslavov, L. N.

    2013-08-01

    Two-pulse modification of the Thomson scattering system that is used at GOL-3 for studies of fast large-amplitude local density fluctuations is described. Two 1054 nm 20 J pulses are generated with two master oscillators that share the same power amplification chain. First experiments indicate existence of shots with a significant change of electron density at adjacent radial locations at ˜100 ns time scale.

  18. An energy confinement study of the MST [Madison Symmetric Torus] reversed field pinch using a Thomson scattering diagnostic

    International Nuclear Information System (INIS)

    Den Hartog, D.J.

    1989-11-01

    Thomson scattering measurements of the central electron temperature and density during the plasma current peak have been performed on the MST Reversed Field Pinch (RFP). This Thomson scattering diagnostic was calibrated for absolute electron density measurements. These measurements of T e and n e , when combined with profile assumptions, were used to calculate estimates of energy confinement time (τ E ) and poloidal beta (β θ ). A standard discharge with I p ∼ 400 kA, F ∼ -0.1, and θ ∼ 1.6 typically exhibited T e ∼ 275 eV, n e ∼ 2.0 x 10 13 cm -3 , τ E ≤ 1 ms, and β θ ≤ 8%. The results of a limited plasma current scaling study did not indicate a strong scaling of T e or τ E with I p . The Thomson scattering diagnostic was used in conjunction with a bolometer, VUV radiation monitor, and edge magnetic coils to study the loss of energy from the plasma. Results indicate that thermal transport from stochastic magnetic fields, particle loss, and radiation are important energy loss processes. The experiments done for this study included an F-scan, a paddle limiter insertion series, and an argon doping series. The plasma maintained a constant βτ during these perturbation experiments, suggesting that increases in one energy loss channel are compensated by drops in other channels and increases in input power to the plasma

  19. Upgrade to the MPTS Thomson scattering diagnostic in preparation for NSTX-U restart

    Science.gov (United States)

    Leblanc, Benoit; Diallo, Ahmed

    2017-10-01

    Upgrades to Multi-Pulse Thomson Scattering (MPTS) diagnostic are in progress. An innovative laser is being added to existing the two 30-Hz Nd:YAG lasers. The new laser also has 30-Hz base operation, but differs notably in its capacity of generating rapid bursts of nominally 50 pulses at either 1 KHz or 10 KHz. This Pulsed-Bursting Laser System (PBLS) is described elsewhere. The current laser delivery optics, which supports two paraxial beam paths, is maintained. One beam path will be occupied by PBLS. The other two laser beams will be actively combined coaxially and will occupy the second beam path. The new laser arrangement will result in a 90-Hz baseline operation, plus the PBLS burst capability. While the existing sample-and-hold electronics is expected to track a 1-KHz sequence, it will not be able to follow a 10-KHz burst. For this purpose, ten radial channels, dedicated to the pedestal region, will be instrumented with 250-MHz digitizers. The NSTX-U longer plasma duration and increased heating power will be conducive to situations with sustained high background light, a condition exacerbated by the absence of viewing dump necessitated by machine geometry. Additional work is slated to study the behavior of the fast signal detection in presence of strong background light. This work is supported by US DoE Contract DE-AC02-09CH11466 and ECRP funding.

  20. X-ray Thomson scattering in warm dense matter at low frequencies.

    Science.gov (United States)

    Murillo, Michael S

    2010-03-01

    The low-frequency portion of the x-ray Thomson scattering spectrum is determined by electrons that follow the slow ion motion. This ion motion is characterized by the ion-ion dynamic structure factor, which contains a wealth of information about the ions, including structure and collective modes. The frequency-integrated (diffraction) contribution is considered first. An effective dressed-particle description of warm dense matter is derived from the quantum Ornstein-Zernike equations, and this is used to identify a Yukawa model for warm dense matter. The efficacy of this approach is validated by comparing a predicted structure with data from the extreme case of a liquid metal; good agreement is found. A Thomas-Fermi model is then introduced to allow the separation of bound and free states at finite temperatures, and issues with the definition of the ionization state in warm dense matter are discussed. For applications, analytic structure factors are given on either side of the Kirkwood line. Finally, several models are constructed for describing the slow dynamics of warm dense matter. Two classes of models are introduced that both satisfy the basic sum rules. One class of models is the "plasmon-pole"-like class, which yields the dispersion of ion-acoustic waves. Damping is then included via generalized hydrodynamics models that incorporate viscous contributions.

  1. A compact, low cost, seven channel polychromator for Thomson scattering measurements

    International Nuclear Information System (INIS)

    Carlstrom, T.N.; DeBoo, J.C.; Evanko, R.; Greenfield, C.M.; Hsieh, C.; Snider, R.T.; Trost, P.

    1990-01-01

    A seven channel polychromator, utilizing high performance interference filters (transmission approx-gt 80%, rejection at laser wavelength>10 5 ), has been tested for use in the multi-Nd:YAG laser Thomson scattering system for the DIII-D tokamak. Unique features of this polychromator are the combination of high throughput, easy alignment, flexibility, compact size, and low cost when compared with other alternatives. Light is introduced to the polychromator (f/1.75) via a fiber optic bundle which permits the use of small (3.0 cm diam) optics and leads to a compact (44x24x8 cm) design, an important design consideration for multiple polychromator systems. The light is cascaded through a series of different bandpass interference filters and relay lenses which are mounted on two precision parallel rails in such a way that alignment is trivial. The relay lenses are positioned directly in front of the filters so that light reflected from the filter passes through the lens twice. This leads to an efficient, compact design and reduces the angle of incidence (4 degree) and the cone angle of light (4.5 degree) seen by the filter, an important factor for narrowband (3.0 nm) filters. The transmission (average 70%) was optimized for 700--1100 nm by using broadband coatings throughout. The output images of each channel (2.3 mm. diam) can be directly coupled to large format (3 mm diam) RCA silicon avalanche photodiode detectors, avoiding the losses caused by fiber optic coupling

  2. Instrument to synchronize Thomson scattering diagnostic measurements with MHD acitivity in a tokamak

    International Nuclear Information System (INIS)

    Wintenberg, A.L.

    1985-04-01

    An instrument to synchronize the firing of a ruby laser for a Thomson scattering diagnostic with plasma oscillations was designed, developed, and evaluated. The instrument will fire the laser at a user-selected phase of an input sine or sawtooth wave with an accuracy of +-15 0 . Allowable frequencies range from 20 to 500 Hz for a sawtooth and from 1 to 30 kHz for a sine wave. The instrument also allows synchronization with a sine wave to be enabled by a preselected sawtooth phase. The instrument uses analog signal processing circuits to separate the signal components, remove unwanted components, and produce zero-phase synchronization pulses. The instrument measures the period between zero-phase pulses in order to produce phase synchronization pulses delayed a fraction of the period from the zero-phase pulses. The laser is fired by the phase synchronization pulse. Unwanted signal components are attenuated by bandpass filters. A digitally controlled self-adjusting bandpass filter for sine processing. The instrument was used to investigate the variation of the electron temperature profile with the phase of the x-ray signal from an Impurity Studies Experiment (ISX-B) plasma exhibiting magnetohydrodynamic (MHD) activity

  3. First operations with the new Collective Thomson Scattering diagnostic on the Frascati Tokamak Upgrade device

    Science.gov (United States)

    Bin, W.; Bruschi, A.; D'Arcangelo, O.; Castaldo, C.; De Angeli, M.; Figini, L.; Galperti, C.; Garavaglia, S.; Granucci, G.; Grosso, G.; Korsholm, S. B.; Lontano, M.; Mellera, V.; Minelli, D.; Moro, A.; Nardone, A.; Nielsen, S. K.; Rasmussen, J.; Simonetto, A.; Stejner, M.; Tartari, U.

    2015-10-01

    Anomalous emissions were found over the last few years in spectra of Collective Thomson Scattering (CTS) diagnostics in tokamak devices such as TEXTOR, ASDEX and FTU, in addition to real CTS signals. The signal frequency, down-shifted with respect to the probing one, suggested a possible origin in Parametric Decay Instability (PDI) processes correlated with the presence of magnetic islands and occurring for pumping wave power levels well below the threshold predicted by conventional models. A threshold below or close to the Electron Cyclotron Resonance Heating (ECRH) power levels could limit, under certain circumstances, the use of the ECRH in fusion devices. An accurate characterization of the conditions for the occurrence of this phenomenon and of its consequences is thus of primary importance. Exploiting the front-steering configuration available with the real-time launcher, the implementation of a new CTS setup now allows studying these anomalous emission phenomena in FTU under conditions of density and wave injection geometry that are more similar to those envisaged for CTS in ITER. The upgrades of the diagnostic are presented as well as a few preliminary spectra detected with the new system during the very first operations in 2014. The present work has been carried out under an EUROfusion Enabling Research project. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  4. Applying the CO2 laser collective Thomson scattering results from JT-60U to other machines

    Science.gov (United States)

    Richards, R. K.; Hutchinson, D. P.; Bennett, C. A.; Kondoh, T.; Miura, Y.; Lee, S.

    2003-03-01

    A collective Thomson scattering (CTS) system based on a pulsed CO2 laser is being developed to demonstrate the feasibility of alpha-particle diagnostics. Tests on this system are being conducted on the JT-60U tokamak. The system consists of a pulsed laser (15 J in 1:s at 10.6:m) and a wide band (˜8 GHz) heterodyne receiver with a quantum-well infrared photodetector [Liu et al., IEEE Electron Device Lett. 16, 253 (1995)]. Stray light is reduced by a notch filter containing hot CO2 gas. The heterodyne receiver is absolutely calibrated using a large area blackbody radiation source [Bennett et al., Appl. Opt. 27, 3324 (1988)]. Results from the tests on JT-60U indicate a larger than expected noise background, especially for the lower velocity measurements determined by the smaller frequency shifts from the laser line. These results are used to estimate the signal-to-noise ratio that would be expected for a CTS diagnostic installed on other devices; ITER ("the way" in Latin), Joint European Torus-Enhanced Performance JET-EP, and axially symmetric divertor experiment (ASDEX). Calculations and possible system improvements are presented.

  5. A Platform for X-Ray Thomson Scattering Measurements of Radiation Hydrodynamics Experiments on the NIF

    Science.gov (United States)

    Lefevre, Heath; Ma, Kevin; Belancourt, Patrick; MacDonald, Michael; Doeppner, Tilo; Keiter, Paul; Kuranz, Carolyn

    2017-10-01

    A recent experiment on the National Ignition Facility (NIF) radiographed the evolution of the Rayleigh-Taylor (RT) instability under high and low drive cases. This experiment showed that under a high drive the growth rate of the RT instability is reduced relative to the low drive case. The high drive launches a radiative shock, increases the temperature of the post-shock region, and ablates the spikes, which reduces the RT growth rate. The plasma parameters must be measured to validate this claim. We present a target design for making X-Ray Thomson Scattering (XRTS) measurements on radiation hydrodynamics experiments on NIF to measure the electron temperature of the shocked region in the above cases. Specifically, we show that a previously fielded NIF radiation hydrodynamics platform can be modified to allow sufficient signal and temperature resolution for XRTS measurements. This work is funded by the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, Grant Number DE-NA0002956 and the National Science Foundation through the Basic Plasma Science and Engineering program.

  6. Modeling and design of radiative hydrodynamic experiments with X-ray Thomson Scattering measurements on NIF

    Science.gov (United States)

    Ma, K. H.; Lefevre, H. J.; Belancourt, P. X.; MacDonald, M. J.; Doeppner, T.; Keiter, P. A.; Kuranz, C. C.; Johnsen, E.

    2017-10-01

    Recent experiments at the National Ignition Facility studied the effect of radiation on shock-driven hydrodynamic instability growth. X-ray radiography images from these experiments indicate that perturbation growth is lower in highly radiative shocks compared to shocks with negligible radiation flux. The reduction in instability growth is attributed to ablation from higher temperatures in the foam for highly radiative shocks. The proposed design implements the X-ray Thomson Scattering (XRTS) technique in the radiative shock tube platform to measure electron temperatures and densities in the shocked foam. We model these experiments with CRASH, an Eulerian radiation hydrodynamics code with block-adaptive mesh refinement, multi-group radiation transport and electron heat conduction. Simulations are presented with SiO2 and carbon foams for both the high temperature, radiative shock and the low-temperature, hydrodynamic shock cases. Calculations from CRASH give estimations for shock speed, electron temperature, effective ionization, and other quantities necessary for designing the XRTS diagnostic measurement. This work is funded by the LLNL under subcontract B614207, and was performed under the auspices of the U.S. DOE by LLNL under Contract No. DE-AC52-07NA27344.

  7. X-Ray Thomson Scattering and Radiography from Spherical Implosions on the OMEGA Laser

    Science.gov (United States)

    Saunders, A. M.; Laziki-Jenei, A.; Doeppner, T.; Landen, O. L.; MacDonald, M.; Nilsen, J.; Swift, D.; Falcone, R. W.

    2017-10-01

    X-ray Thomson scattering (XRTS) is an experimental technique that directly probes the physics of warm dense matter by measuring electron density, electron temperature, and ionization state. XRTS in combination with x-ray radiography offers a unique ability to measure an absolute equation of state (EOS) from material under compression. Recent experiments highlight uncertainties in EOS models and the predicted ionization of compressed matter, suggesting more validation of models is needed. We present XRTS and x-ray radiography measurements taken at the OMEGA Laser Facility from directly-driven solid carbon spheres at densities on the order of 1x1024 g cm-3 and temperatures on the order of 30 eV. The results shed light on the equations of state of matter under compression. This work performed under auspices of the US Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344 and under the Stewardship Science Graduate Fellowship, Grant Number DE- NA0002135.

  8. Plasma cleaning of ITER edge Thomson scattering mock-up mirror in the EAST tokamak

    Science.gov (United States)

    Yan, Rong; Moser, Lucas; Wang, Baoguo; Peng, Jiao; Vorpahl, Christian; Leipold, Frank; Reichle, Roger; Ding, Rui; Chen, Junling; Mu, Lei; Steiner, Roland; Meyer, Ernst; Zhao, Mingzhong; Wu, Jinhua; Marot, Laurent

    2018-02-01

    First mirrors are the key element of all optical and laser diagnostics in ITER. Facing the plasma directly, the surface of the first mirrors could be sputtered by energetic particles or deposited with contaminants eroded from the first wall (tungsten and beryllium), which would result in the degradation of the reflectivity. The impurity deposits emphasize the necessity of the first mirror in situ cleaning for ITER. The mock-up first mirror system for ITER edge Thomson scattering diagnostics has been cleaned in EAST for the first time in a tokamak using radio frequency capacitively coupled plasma. The cleaning properties, namely the removal of contaminants and homogeneity of cleaning were investigated with molybdenum mirror insets (25 mm diameter) located at five positions over the mock-up plate (center to edge) on which 10 nm of aluminum oxide, used as beryllium proxy, were deposited. The cleaning efficiency was evaluated using energy dispersive x-ray spectroscopy, reflectivity measurements and x-ray photoelectron spectroscopy. Using argon or neon plasma without magnetic field in the laboratory and with a 1.7 T magnetic field in the EAST tokamak, the aluminum oxide films were homogeneously removed. The full recovery of the mirrors’ reflectivity was attained after cleaning in EAST with the magnetic field, and the cleaning efficiency was about 40 times higher than that without the magnetic field. All these results are promising for the plasma cleaning baseline scenario of ITER.

  9. Using X-ray Thomson Scattering to Characterize Highly Compressed, Near-Degenerate Plasmas at the NIF

    Science.gov (United States)

    Doeppner, Tilo; Kraus, D.; Neumayer, P.; Bachmann, B.; Divol, L.; Kritcher, A. L.; Landen, O. L.; Fletcher, L.; Glenzer, S. H.; Falcone, R. W.; MacDonald, M. J.; Saunders, A.; Witte, B.; Redmer, R.; Chapman, D.; Baggott, R.; Gericke, D. O.; Yi, S. A.

    2017-10-01

    We are developing x-ray Thomson scattering for implosion experiments at the National Ignition Facility to characterize plasma conditions in plastic and beryllium capsules near stagnation, reaching more than 20x compression and electron densities of 1025 cm-3, corresponding to a Fermi energy of 170 eV. Using a zinc He- α x-ray source at 9 keV, experiments at a large scattering angle of 120° measure non-collective scattering spectra with high sensitivity to K-shell ionization, and find higher charge states than predicted by widely used ionization models. Reducing the scattering angle to 30° probes the collective scattering regime with sensitivity to collisions and conductivity. We will discuss recent results and future plans. This work was performed under the auspices of the US Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  10. Development of sequence and regular band lasers for use as local oscillators in Thomson scattering alpha particle diagnostics (abstract)

    Science.gov (United States)

    Bennett, C. A.; Hutchinson, D. P.; Vander Sluis, K. L.; Staats, P. A.

    1985-05-01

    Heterodyne detection will be used to measure the scattered signal from a 100-MW pulsed CO2 laser Thomson scattered from energetic alpha particles. This measurement requires local oscillators displaced from the pump line by 6 to 21 GHz. We are developing cw sequence and regular band N2O and CO2 lasers which provide many lines in the required frequency range. The sequence lines are obtained by using a small in-cavity hot cell. Operating characteristics will be discussed for a variety of experimental arrangements.

  11. Application of Thomson Scattering System at 1.06 μm for Study of Plasma Density Dynamics at Multimirror Trap GOL-3

    International Nuclear Information System (INIS)

    Polosatkin, S.V.; Burdakov, A.V.; Ivantsivsky, M.V.; Koidan, V.S.; Semionov, A.F.; Rovenskikh, V.V.

    2005-01-01

    Thomson scattering system for measurements of radial profile of plasma density (range 0.5-5x10 21 m -3 ) with temperature up to 2 keV was developed at the GOL-3 facility. First harmonics (λ=1.06 μm) of Nd glass laser is used. Scattered light from different points of plasma cross-section is imaged to a set of quartz optical fibers and detected by avalanche photodiodes.During the first 10 μs after start of the relativistic electron beam injection the intense light emission from plasma is observed. Single powerful laser pulse is used for providing of good signal-noise ratio in this period. Later the plasma radiation intensity decreases and the less powerful laser oscillator operated in multiple-pulsed regime is used.Description of the diagnostics, methodical aspects of operation, and results of the density dynamics measurements are presented in the paper

  12. Calculation of the nonlinear relativistic Thomson scattering fields and Its application to electron distribution function diagnostic

    Science.gov (United States)

    Guasp, J.; Pastor, I.; Álvarez-Estrada, R. F.; Castejón, F.

    2015-02-01

    Analytical results obtained recently of the ab-initio classical incoherent Thomson Scattering (TS) spectrum from a single-electron (Alvarez-Estrada et al 2012 Phys. Plasmas 19 062302) have been numerically implemented in a paralelized code to efficiently compute the TS emission from a given electron distribution function, irrespective of its characteristics and/or the intensity of the incoming radiation. These analytical results display certain differences, when compared with other authors, in the general case of incoming linearly and circularly polarized radiation and electrons with arbitrary initial directions. We regard such discrepancies and the ubiquitous interest in TS as motivations for this work. Here, we implement some analytical advances (like generalized Bessel functions for incoming linearly polarized radiation) in TS. The bulk of this work reports on the efficient computation of TS spectra (based upon our analytical approach), for an electron population having an essentially arbitrary distribution function and for both incoming linearly and circularly polarized radiation. A detailed comparison between the present approach and a previous Monte Carlo one (Pastor et al 2011 Nuclear Fusion 51 043011), dealing with the ab-initio computation of TS spectra, is reported. Both approaches are shown to fully agree with each other. As key computational improvements, the analytical technique yields a × 30 to × 100 gain in computation time and is a very flexible tool to compute the scattered spectrum and eventually the scattered electromagnetic fields in the time domain. The latter are computed explicitly here for the first time, as far as we know. Scaling laws for the power integrated over frequency versus initial kinetic energy are studied for the case of isotropic and monoenergetic electron distribution functions and their potential application as diagnostic tools for high-energy populations is briefly discussed. Finally, we discuss the application of these

  13. Initial Thomson Scattering Survey of Local Helicity Injection and Ohmic Plasmas at the Pegasus Toroidal Experiment

    Science.gov (United States)

    Schlossberg, D. J.; Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Winz, G. R.

    2014-10-01

    A multipoint Thomson scattering diagnostic has recently been installed on the Pegasus ST. The system utilizes a frequency-doubled Nd:YAG laser (λ0 ~ 532 nm), spectrometers with volume phase holographic gratings, and a gated, intensified CCD camera. It provides measurements of Te and ne at 8 spatial locations for each spectrometer once per discharge. A new multiple aperture and beam dump system has been implemented to mitigate interference from stray light. This system has provided initial measurements in the core region of plasmas initiated by local helicity injection (LHI), as well as conventional Ohmic L- and H-mode discharges. Multi-shot averages of low-density (ne ~ 3 ×1018 m-3) , Ip ~ 0 . 1 MA LHI discharges show central Te ~ 75 eV at the end of the helicity injection phase. Ip ~ 0 . 13 MA Ohmic plasmas at moderate densities (ne ~ 2 ×1019 m-3) have core Te ~ 150 eV in L-mode. Generally, these plasmas do not reach transport equilibrium in the short 25 ms pulse length available. After an L-H transition, strong spectral broadening indicates increasing Te, to values above the range of the present spectrometer system with a high-dispersion VPH grating. Near-term system upgrades will focus on deploying a second spectrometer, with a lower-dispersion grating capable of measuring the 0.1-1.0 keV range. The second spectrometer system will also increase the available number of spatial channels, enabling study of H-mode pedestal structure. Work supported by US DOE Grant DE-FG02-96ER54375.

  14. First measurements of electron temperature and density with divertor Thomson Scattering in radiative divertor discharges on DIII-D

    International Nuclear Information System (INIS)

    Allen, S.L.; Hill, D.N.; Carlstrom, T.N.; Nilson, D.G.

    1996-10-01

    We have obtained the first measurements of n e and T e in the DIII-D divertor region with a multi-pulse (20 Hz) Divertor Thomson Scattering (DTS) system. Eight measurement locations are distributed vertically up to 21 cm above the divertor plate. Two-dimensional distributions have been obtained by sweeping the divertor plasma across the DTS measurement location. Several operating modes have been studied, including ohmic, L-mode, Elming H-mode, and Radiative Divertor operation with puffing of D 2 and impurities. Mapping of the data to either the (L pol , φ) or (R, Z) planes with the EFIT equilibrium is used to analyze the 2D profiles. We find that in ELMing H-mode: n e , T e , and P e are relatively constant along field lines from the X-point to the divertor plate, especially near the separatrix field line. With D 2 puffing, the DTS profiles indicate that T e in a large part of divertor region below the X-point is dramatically reduced from ∼30-40 eV in ELMing H-mode to 1-2 eV. This results in a fairly uniform low-T e divertor, with an increased electron density in the range of 2 to 4 x 10 20 m -3 . Detailed comparisons of the spatial profiles of n e , T e , and electron pressure P e , are presented for several operating modes. In addition, these data are compared with initial calculations from the UEDGE fluid code

  15. Improved cross-calibration of Thomson scattering and electron cyclotron emission with ECH on DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Brookman, M. W., E-mail: brookmanmw@fusion.gat.com [Institute for Fusion Studies, University of Texas at Austin, Austin, Texas 78712 (United States); Austin, M. E.; McLean, A. G. [Lawrence Livermore National Lab, Livermore, California 94500 (United States); Carlstrom, T. N.; Hyatt, A. W.; Lohr, J. [General Atomics, San Diego, California 92122 (United States)

    2016-11-15

    Thomson scattering produces n{sub e} profiles from measurement of scattered laser beam intensity. Rayleigh scattering provides a first calibration of the relation n{sub e} ∝ I{sub TS}, which depends on many factors (e.g., laser alignment and power, optics, and measurement systems). On DIII-D, the n{sub e} calibration is adjusted against an absolute n{sub e} from the density-driven cutoff of the 48 channel 2nd harmonic X-mode electron cyclotron emission system. This method has been used to calibrate Thomson n{sub e} from the edge to near the core (r/a > 0.15). Application of core electron cyclotron heating improves the quality of cutoff and depth of its penetration into the core, and also changes underlying MHD activity, minimizing crashes which confound calibration. Less fueling is needed as “ECH pump-out” generates a plasma ready to take up gas. On removal of gyrotron power, cutoff penetrates into the core as channels fall successively and smoothly into cutoff.

  16. Ion temperature measurement of a tokamak plasma by collective Thomson scattering of D2O laser radiation

    International Nuclear Information System (INIS)

    Behn, R.; Salito, S.A.; Siegrist, M.R.; Dicken, D.; Hackmann, J.

    1988-10-01

    A D 2 O FIR laser emitting 0.5 J in 1.4 μs at 385 μm and a heterodyne receiver system comprising a Schottky barrier diode mixer with a noise temperature of 8000 K (DSB) were used in a Thomson scattering experiment to measure the ion temperature of a tokamak plasma during a single laser shot. Series of measurements under reproducible plasma conditions have been carried out in H, D and He-plasmas. Their statistical analysis yielded a typical relative error of 25 % for a single shot measurement. (author) 9 figs., 2 tabs., 7 refs

  17. Diagnosis of energetic ions and ion composition in fusion plasmas by collective Thomson scattering of mm-waves

    DEFF Research Database (Denmark)

    Bindslev, Henrik; Korsholm, Søren Bang; Leipold, Frank

    2012-01-01

    In fusion plasmas, the dominant heating source will be fusion generated energetic ions slowing down in the plasma. The same ions can also drive waves and instabilities in the plasma. Their distribution in velocity and in space has major impact on plasma dynamics, and plasma dynamics in turn affects...... the energetic ion distributions. The dynamics of energetic ions is thus important to measure in order to understand fusion plasmas, and important to monitor as part of input to plasma control. The collective Thomson scattering of millimeter waves has proven to be a valuable means of diagnosing energetic ion...

  18. Benchmark and combined velocity-space tomography of fast-ion D-alpha spectroscopy and collective Thomson scattering measurements

    DEFF Research Database (Denmark)

    Jacobsen, Asger Schou; Salewski, Mirko; Geiger, B.

    2016-01-01

    measurements without using a numerical simulation as common reference. Combined velocity-space tomographies from FIDA and CTS measurements confirm that sawtooth crashes reduce the fast-ion phase-space densities in the plasma center and affect ions with pitches close to one more strongly than those with pitches......We demonstrate the combination of fast-ion D-alpha spectroscopy (FIDA) and collective Thomson scattering (CTS) measurements to determine a common best estimate of the fastion velocity distribution function by velocity-space tomography. We further demonstrate a benchmark of FIDA tomography and CTS...

  19. Optics for electron cyclotron resonance heating and collective Thomson scattering at the stellarator W7-X

    DEFF Research Database (Denmark)

    Kasparek, W.; Erckmann, V.; Laqua, H. P.

    2017-01-01

    This paper will provide a brief review on the optical transmission system, describe its performance and first experiences, and will concentrate on new developments like in-vessel grating reflectors, Remote-steering (RS) antennas used as launchers and receivers for ECRH and collective Thomson scat...

  20. Image processing methods for noise reduction in the TJ-II Thomson Scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Dormido-Canto, S., E-mail: sebas@dia.uned.es [Departamento de Informatica y Automatica, UNED, Madrid 28040 (Spain); Farias, G. [Pontificia Universidad Catolica de Valparaiso, Valparaiso (Chile); Vega, J.; Pastor, I. [Asociacion EURATOM/CIEMAT para Fusion, Madrid 28040 (Spain)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We describe an approach in order to reduce or mitigate the stray-light on the images and show the exceptional results. Black-Right-Pointing-Pointer We analyze the parameters to take account in the proposed process. Black-Right-Pointing-Pointer We report a simplified exampled in order to explain the proposed process. - Abstract: The Thomsom Scattering diagnostic of the TJ-II stellarator provides temperature and density profiles. The CCD camera acquires images corrupted with noise that, in some cases, can produce unreliable profiles. The main source of noise is the so-called stray-light. In this paper we describe an approach that allows mitigation of the effects that stray-light has on the images: extraction regions with connected-components. In addition, the robustness and effectiveness of the noise reduction technique is validated in two ways: (1) supervised classification and (2) comparison of electron temperature profiles.

  1. Design and testing of a magnetic shield for the Thomson scattering photomultiplier tubes in the stray fields of the ERASMUS tokamak

    International Nuclear Information System (INIS)

    Desoppere, E.; Van Oost, G.

    1983-01-01

    A multiple coaxial shield system has been designed for the photomultiplier tubes of the ERASMUS tokamak Thomson scattering diagnostic. A stray field of 75 x 10 -4 T was reduced to 0.01 x 10 -4 T for a field parallel to the tube axis, and to 0.03 x 10 -4 T for a perpendicular field

  2. Correction of the spectral calibration of the Joint European Torus core light detecting and ranging Thomson scattering diagnostic using ray tracing

    NARCIS (Netherlands)

    Hawke, J.; Scannell, R.; Maslov, M.; Migozzi, J. B.

    2013-01-01

    This work isolated the cause of the observed discrepancy between the electron temperature (T-e) measurements before and after the JET Core LIDAR Thomson Scattering (TS) diagnostic was upgraded. In the upgrade process, stray light filters positioned just before the detectors were removed from the

  3. Comparison of multialkali and GaAs photocathode detectors for Joint European Torus edge light detection and ranging Thomson scattering profiles

    NARCIS (Netherlands)

    Kempenaars, M.; Nielsen, P.; Pasqualotto, R.; Gowers, C.; Beurskens, M.

    2004-01-01

    The Joint European Torus (JET) tokamak has two light detection and ranging (LIDAR) Thomson scattering systems, one for the core and one dedicated to the edge T-e and n(e) profiles. The LIDAR scheme is unique to JET and is envisaged for use on ITER. The system's spatial resolution is defined by

  4. Collective Thomson scattering based on CO2 laser for ion energy spectrum measurements in JT-60U

    Science.gov (United States)

    Kondoh, T.; Miura, Y.; Lee, S.; Richards, R. K.; Hutchinson, D. P.; Bennett, C. A.

    2003-03-01

    A collective Thomson scattering (CTS) diagnostic system based on a pulsed CO2 laser has been developed and brought into operation to establish a measurement technique for ion temperature and the energy spectrum of fast ions. The pulsed CO2 laser (wavelength 10.6 μm, beam energy 15 J, pulse width 1 μs) and a heterodyne receiver were installed on the JT-60U tokamak. Calculation of the scattered power spectrum from high temperature plasma in JT-60U shows that a good signal-to-noise value is expected for the bulk-ion temperature measurement. Calibration of the heterodyne receiver system has been carried out using a large area (12×12 cm2) blackbody radiation source. Commissioning of the CTS system by injecting the CO2 laser into the plasmas has been accomplished. However, a scattered signal has not yet been detected due to electrical noise originating from the pulsed lasers discharge and stray signal coming from mode impurities in the pulsed laser. After the electrical and stray light reduction, ion temperature will be evaluated from the scattered spectrum using the CTS system.

  5. Fast ion collective Thomson scattering - present results and plans for ITER

    DEFF Research Database (Denmark)

    Korsholm, Søren Bang; Bindslev, Henrik; Furtula, Vedran

    by the CTS group at Risø DTU building on the experiences and expertise gained from the group’s construction and current operation of the CTS diagnostic systems on the tokamaks TEXTOR and ASDEX Upgrade. This contribution will introduce the technique of CTS, give an overview of the current diagnostic systems......Moving towards the era of burning fusion plasmas, a better knowledge of the physics of highly energetic particles, such as the 3.5 MeV fusion born alpha particles, becomes necessary. Diagnosing the fast ions in a fusion plasma is a challenging task, but the technique of collective Thomson...

  6. Interaction of relativistic electrons with an intense laser pulse: High-order harmonic generation based on Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Hack, Szabolcs [ELI-ALPS, ELI-HU Non-Profit Ltd., Dugonics tér 13, H-6720 Szeged (Hungary); Department of Theoretical Physics, University of Szeged, Tisza L. krt. 84-86, H-6720 Szeged (Hungary); Varró, Sándor [ELI-ALPS, ELI-HU Non-Profit Ltd., Dugonics tér 13, H-6720 Szeged (Hungary); Wigner Research Center for Physics, SZFI, PO Box 49, H-1525 Budapest (Hungary); Czirják, Attila [ELI-ALPS, ELI-HU Non-Profit Ltd., Dugonics tér 13, H-6720 Szeged (Hungary); Department of Theoretical Physics, University of Szeged, Tisza L. krt. 84-86, H-6720 Szeged (Hungary)

    2016-02-15

    We investigate nonlinear Thomson scattering as a source of high-order harmonic radiation with the potential to enable attosecond light pulse generation. We present a new analytic solution of the electron’s relativistic equations of motion in the case of a short laser pulse with a sine-squared envelope. Based on the single electron emission, we compute and analyze the radiated amplitude and phase spectrum for a realistic electron bunch, with special attention to the correct initial values. These results show that the radiation spectrum of an electron bunch in head-on collision with a sufficiently strong laser pulse of sine-squared envelope has a smooth frequency dependence to allow for the synthesis of attosecond light pulses.

  7. Interaction of relativistic electrons with an intense laser pulse: High-order harmonic generation based on Thomson scattering

    International Nuclear Information System (INIS)

    Hack, Szabolcs; Varró, Sándor; Czirják, Attila

    2016-01-01

    We investigate nonlinear Thomson scattering as a source of high-order harmonic radiation with the potential to enable attosecond light pulse generation. We present a new analytic solution of the electron’s relativistic equations of motion in the case of a short laser pulse with a sine-squared envelope. Based on the single electron emission, we compute and analyze the radiated amplitude and phase spectrum for a realistic electron bunch, with special attention to the correct initial values. These results show that the radiation spectrum of an electron bunch in head-on collision with a sufficiently strong laser pulse of sine-squared envelope has a smooth frequency dependence to allow for the synthesis of attosecond light pulses.

  8. Energy-angle correlation correction algorithm for monochromatic computed tomography based on Thomson scattering X-ray source

    Science.gov (United States)

    Chi, Zhijun; Du, Yingchao; Huang, Wenhui; Tang, Chuanxiang

    2017-12-01

    The necessity for compact and relatively low cost x-ray sources with monochromaticity, continuous tunability of x-ray energy, high spatial coherence, straightforward polarization control, and high brightness has led to the rapid development of Thomson scattering x-ray sources. To meet the requirement of in-situ monochromatic computed tomography (CT) for large-scale and/or high-attenuation materials based on this type of x-ray source, there is an increasing demand for effective algorithms to correct the energy-angle correlation. In this paper, we take advantage of the parametrization of the x-ray attenuation coefficient to resolve this problem. The linear attenuation coefficient of a material can be decomposed into a linear combination of the energy-dependent photoelectric and Compton cross-sections in the keV energy regime without K-edge discontinuities, and the line integrals of the decomposition coefficients of the above two parts can be determined by performing two spectrally different measurements. After that, the line integral of the linear attenuation coefficient of an imaging object at a certain interested energy can be derived through the above parametrization formula, and monochromatic CT can be reconstructed at this energy using traditional reconstruction methods, e.g., filtered back projection or algebraic reconstruction technique. Not only can monochromatic CT be realized, but also the distributions of the effective atomic number and electron density of the imaging object can be retrieved at the expense of dual-energy CT scan. Simulation results validate our proposal and will be shown in this paper. Our results will further expand the scope of application for Thomson scattering x-ray sources.

  9. The use of ultraviolet Thomson scattering as a versatile diagnostic for detailed measurements of a collisional laser produced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Tracy, Mark David [Univ. of California, Davis, CA (United States)

    1993-01-08

    Collective Thomson scattering from ion-acoustic waves at 266nm is used to obtain spatially resolved, two-dimensional electron density, sound speed, and radial drift profiles of a collisional laser plasma. An ultraviolet diagnostic wavelength minimizes the complicating effects of inverse bremsstrahlung and refractive turning in the coronal region of interest, where the electron densities approach nc/10. Laser plasmas of this type are important because they model some of the aspects of the plasmas found in high-gain laser-fusion pellets irradiated by long pulse widths where the laser light is absorbed mostly in the corona. The experimental results and LASNEX simulations agree within a percent standard deviation of 40% for the electron density and 50% for the sound speed and radial drift velocity. Thus it is shown that the hydrodynamics equations with classical coefficients and the numerical approximations in LASNEX are valid models of laser-heated, highly collisional plasmas. The versatility of Thomson scattering is expanded upon by extending existing theory with a Fokker-Planck based model to include plasmas that are characterized by (0 ≤ kiaλii ≤ ∞) and ZTe/Ti, where kia is the ion- acoustic wave number, λii is the ion-ion mean free path, Z is the ionization state of the plasma, and Te. Ti are the electron and ion temperatures in electron volts respectively. The model is valid for plasmas in which the electrons are approximately collisionless, (kiaλei, kiaλee ≥ 1), and quasineutrality holds, (α ≥1), where α = 1/kλDE and λDe is the electron Debye length. This newly developed model predicts the lineshape of the ion-acoustic Thomson spectra and when fit to experimental data provides a direct measurement of the relative thermal flow velocity between the electrons and ions.

  10. On velocity space interrogation regions of fast-ion collective Thomson scattering at ITER

    DEFF Research Database (Denmark)

    Salewski, Mirko; Nielsen, Stefan Kragh; Bindslev, Henrik

    2011-01-01

    the collective scattering in well-defined regions in velocity space, here dubbed interrogation regions. Since the CTS instrument measures entire spectra of scattered radiation, many different interrogation regions are probed simultaneously. We here give analytic expressions for weight functions describing...

  11. Modification of the collective Thomson scattering radiometer in the search for parametric decay on TEXTOR

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Salewski, Mirko; Bongers, W.

    2012-01-01

    Strong scattering of high-power millimeter waves at 140 GHz has been shown to take place in heating and current-drive experiments at TEXTOR when a tearing mode is present in the plasma. The scattering signal is at present supposed to be generated by the parametric decay instability. Here we descr...

  12. Measurement of electron density of the plasma in the Tokamak TCABR, through Thomson scattering diagnostic; Medida da densidade eletronica do plasma no Tokamak TCABR, atraves do diagnostico Espalhamento Thomson

    Energy Technology Data Exchange (ETDEWEB)

    Jeronimo, Leonardo Cunha

    2013-07-01

    Over the last few years is remarkable, so increasingly evident the need for a new source of energy for mankind. One promising option is through nuclear fusion, where the plasma produced in the reactor can be converted into electrical energy. Therefore, knowing the characteristics of this plasma is very important to control it and understand it so desirable. One of the diagnostic options is called Thomson scattering . This is considered the most reliable method for the determination of important plasma parameters such as temperature and electron density, and may also help in the study and explanation of various internal mechanisms. The great advantage lies in the tact that they consist of a direct measurement and nonperturbative. But it is a diagnosis whose installation and execution is admittedly complex, limiting it only a few laboratories in the fíeld of fusion for the world. Among the main difficulties, wc can highlight the fact that the scattered signal is very small, thus requiring a large increase of the incident power. Moreover, the external physical conditions can cause mechanical vibrations that eliminate or minimize them as much as possible, is a great challenge, considering the optical micrometrically very sensitive and needs involved in the system. This work describes the entire process of installation and operation of Thomson scattering diagnostic in tokamak TCABR and through this diagnosis, we work on results of electron temperature, to finally be able to calculate the electron density of the plasma. (author)

  13. Correction of the spectral calibration of the Joint European Torus core light detecting and ranging Thomson scattering diagnostic using ray tracing

    Energy Technology Data Exchange (ETDEWEB)

    Hawke, J. [FOM Institute DIFFER – Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, 3430 BE Nieuwegein (Netherlands); Scannell, R.; Maslov, M. [EURATOM-CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Migozzi, J. B. [JBM Optique, 4 Rue du Calvaire Bâtiment 11, 92210 Saint Cloud (France); Collaboration: JET-EFDA Contributors

    2013-10-15

    This work isolated the cause of the observed discrepancy between the electron temperature (T{sub e}) measurements before and after the JET Core LIDAR Thomson Scattering (TS) diagnostic was upgraded. In the upgrade process, stray light filters positioned just before the detectors were removed from the system. Modelling showed that the shift imposed on the stray light filters transmission functions due to the variations in the incidence angles of the collected photons impacted plasma measurements. To correct for this identified source of error, correction factors were developed using ray tracing models for the calibration and operational states of the diagnostic. The application of these correction factors resulted in an increase in the observed T{sub e}, resulting in the partial if not complete removal of the observed discrepancy in the measured T{sub e} between the JET core LIDAR TS diagnostic, High Resolution Thomson Scattering, and the Electron Cyclotron Emission diagnostics.

  14. Design and calibration of a two-channel low-noise heterodyne receiver for use in a CO2 laser Thomson scattering alpha particle diagnostic

    Science.gov (United States)

    Bennett, C. A.; Richards, R. K.; Hutchinson, D. P.

    1988-03-01

    A dual channel low noise heterodyne receiver has been constructed as part of a development effort to build a carbon dioxide laser based Thomson scattering alpha particle diagnostic for a burning plasma experiment. The receiver employs two wide bandwidth (greater than 1 GHz) HgCdTe photovoltaic mixers followed by low noise IF amplifiers. A noise equivalent power of less than 3.0 times 10 to the 20th power WHz has been demonstrated. Design details and calibration methods are described.

  15. Commissioning activities and first results from the collective Thomson scattering diagnostic on ASDEX Upgrade (invited)

    DEFF Research Database (Denmark)

    Meo, Fernando; Bindslev, Henrik; Korsholm, Søren Bang

    2008-01-01

    GHz) to resolve the one-dimensional velocity distribution of the confined fast ions. The steerable antennas will allow different scattering geometries to fully explore the anisotropic fast ion distributions at different spatial locations. This paper covers the capabilities and operational limits...... of the system. First results in near perpendicular of scattered spectra in a neutral beam injection (NBI) and ion cyclotron resonance heating (ICRH) plasma (minority hydrogen) on ASDEX Upgrade have shown evidence of ICRH heating phase of hydrogen. ©2008 American Institute of Physics...

  16. Study of Stark broadening of Li I 460 and 497 nm spectral lines with independent plasma diagnostics by Thomson scattering

    Science.gov (United States)

    Dzierżȩga, Krzysztof; Piȩta, Tomasz; Zawadzki, Witold; Stambulchik, Evgeny; Gavrilović-Božović, Marijana; Jovićević, Sonja; Pokrzywka, Bartłomiej

    2018-02-01

    We present results of experimental and theoretical studies of the Stark broadening of the Li I 460 nm spectral line with forbidden components and of the isolated 497 nm line. Plasma was induced by Nd:YAG laser radiation at 1064 nm with pulse duration ∼4.5 ns. Laser-induced plasma was generated in front of the alumina pellet, with some content of Li2CO3, placed in a vacuum chamber filled with argon under reduced pressure. Plasma diagnostics was performed using the laser Thomson scattering technique, free from assumptions about the plasma equilibrium state and its composition and so independently of plasma emission spectra. Spatially resolved spectra with Li lines were obtained from the measured, laterally integrated ones applying the inverse Abel transform. The Stark profiles were calculated by computer simulation method assuming a plasma in the local thermodynamic equilibrium. Calculations were performed for experimentally-inferred electron densities and temperatures, from 1.422 × 1023 to 3.55 × 1022 m‑3 and from 1.96 eV to 1.04 eV, respectively. Our studies show very good agreement between experimental Stark profiles and those computer simulated.

  17. Spectrum response and analysis of 77 GHz band collective Thomson scattering diagnostic for bulk and fast ions in LHD plasmas

    DEFF Research Database (Denmark)

    Nishiura, M.; Kubo, S.; Tanaka, K.

    2014-01-01

    A collective Thomson scattering (CTS) diagnostic was developed and used to measure the bulk and fast ions originating from 180 keV neutral beams in the Large Helical Device (LHD). Electromagnetic waves from a gyrotron at 77 GHz with 1 MW power output function as both the probe and electron......, a stray radiation component was observed in the CTS spectrum whereas it was negligibly small at low density. The CTS spectrum was measured and analysed after the in situ beam alignment using a beam scan. Qualitatively, the CTS spectrogram shows consistent response to ion temperatures of 1–2 ke......V for electron densities of (1–2) × 1019 m−3 and electron temperatures of 2–4 keV. The measured CTS spectrum shows an asymmetric shape at the foot of the bulk-ion region during the injection of 180 keV fast ions. This shape is explained by the fast-ion distribution in the velocity space (v‖, v⊥) based on Monte...

  18. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic.

    Science.gov (United States)

    Swadling, G F; Ross, J S; Datte, P; Moody, J; Divol, L; Jones, O; Landen, O

    2016-11-01

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause "blanking" (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm -2 . This is significantly above the expected threshold for the onset of "blanking" effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate "blanking." Estimates suggest that an areal density of 10 19 cm -2 Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  19. Performance measurements of the collective Thomson scattering receiver at ASDEX Upgrade

    DEFF Research Database (Denmark)

    Furtula, Vedran; Leipold, Frank; Salewski, Mirko

    2012-01-01

    of magnitude stronger than the signal to be detected. The receiver heterodynes the frequencies of scattered radiation (100–110 GHz) to intermediate frequencies (IF) (4.5–14.5 GHz). The IF signal is divided into 50 IF channels tightly spaced in frequency space which are terminated by square-law Schottky...

  20. Fast-ion dynamics in the TEXTOR tokamak measured by collective Thomson scattering

    DEFF Research Database (Denmark)

    Bindslev, H.; Nielsen, S.K.; Porte, L.

    2006-01-01

    and ion cyclotron resonance heating. The temporal behavior of the spatially resolved fast-ion velocity distribution is inferred from the received scattered radiation. The fast-ion dynamics at sawteeth and the slowdown after switch off of auxiliary heating is resolved in time. The latter is shown...

  1. Reduction of the Thomson scattering cross-section in a strong circularly polarized light field in plasma with the change of its spectrum

    Science.gov (United States)

    Korobkin, Vladlen V.; Romanovsky, Michael Y.

    1992-06-01

    It is shown that in a strong circularly polarized laser field, classical electron motion around the ions can occur. The non-relativistic scattering by these electrons in plasma has a certain (Thomson) cross-section only in the limit of a very strong field (it is practically the case of relativistic motion of electrons). In a circularly polarized field with an amplitude on the order of the inneratomic one, the cross section of this process is less. In the spectrum that the scattering of this field gives in plasma, there are non-ion satellites along with the basic frequency.

  2. Scattering and absorption of particles emitted by a point source in a cluster of point scatterers

    International Nuclear Information System (INIS)

    Liljequist, D.

    2012-01-01

    A theory for the scattering and absorption of particles isotropically emitted by a point source in a cluster of point scatterers is described and related to the theory for the scattering of an incident particle beam. The quantum mechanical probability of escape from the cluster in different directions is calculated, as well as the spatial distribution of absorption events within the cluster. A source strength renormalization procedure is required. The average quantum scattering in clusters with randomly shifting scatterer positions is compared to trajectory simulation with the aim of studying the validity of the trajectory method. Differences between the results of the quantum and trajectory methods are found primarily for wavelengths larger than the average distance between nearest neighbour scatterers. The average quantum results include, for example, a local minimum in the number of absorption events at the location of the point source and interference patterns in the angle-dependent escape probability as well as in the distribution of absorption events. The relative error of the trajectory method is in general, though not generally, of similar magnitude as that obtained for beam scattering.

  3. Clasificador de Imágenes del Diagnóstico Thomson Scattering del TJ II Basado en Template Matching

    Directory of Open Access Journals (Sweden)

    Jesús A. Vega Sánchez

    2010-07-01

    Full Text Available La automatización del análisis de las señales generadas en un ambiente de fusión nuclear constituye una meta importante. El presente trabajo se encuadra en el contexto del desarrollo de clasificadores automáticos para las señales generadas en el Diagnóstico Thomson Scattering del TJ II, siendo este un ambiente de fusión específico. Dos etapas fundamentales son consideradas en el diseño del clasificador: el procesamiento de las señales y extracción de sus características, por un lado, y la clasificación, por otro. La primera es implementada, en el trabajo, recurriendo a las transformadas wavelet mientras que la segunda es implementada a través de la comparación entre las características de las señales disponibles y las de un conjunto de señales previamente seleccionadas como prototipos (template matching, operación esta que es efectuada utilizando a técnicas de trayectoria de búsqueda óptimas basadas en programación dinámica. En el mismo se muestra que la metodología empleada permite la clasificación de las señales en cuestión y que con un entrenamiento adecuado se puede extraer un buen rendimiento al clasificador desarrollado.

  4. Heldi Thomson

    Index Scriptorium Estoniae

    1997-01-01

    Teaduspreemia autorite kollektiivile arstiteaduse alal töö "Vähktõbi Eestis 1968-1992: haigestumus, levimus, elulemus ja suremus" eest - Mati Rahu (kollektiivi juht), Tiiu Aarelaid, Kaja Gornoi, Heldi Thomson

  5. Measurements of the fast-ion distribution function at ASDEX upgrade by collective Thomson scattering (CTS) using active and passive views

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Stejner Pedersen, Morten; Rasmussen, Jesper

    2015-01-01

    Collective Thomson scattering (CTS) can provide measurements of the confined fast-ion distribution function resolved in space, time and 1D velocity space. On ASDEX Upgrade, the measured spectra include an additional signal which previously has hampered data interpretation. A new set-up using two......, the measured spectra agree quantitatively with the synthetic spectra in periods with and without NBI heating. For the discharges investigated, the central velocity distribution of neutral beam ions can be described by classical slowing down. These results will have a major impact on ITER physics exploration...

  6. Upgrade of the automatic analysis system in the TJ-II Thomson Scattering diagnostic: New image recognition classifier and fault condition detection

    International Nuclear Information System (INIS)

    Makili, L.; Vega, J.; Dormido-Canto, S.; Pastor, I.; Pereira, A.; Farias, G.; Portas, A.; Perez-Risco, D.; Rodriguez-Fernandez, M.C.; Busch, P.

    2010-01-01

    An automatic image classification system based on support vector machines (SVM) has been in operation for years in the TJ-II Thomson Scattering diagnostic. It recognizes five different types of images: CCD camera background, measurement of stray light without plasma or in a collapsed discharge, image during ECH phase, image during NBI phase and image after reaching the cut off density during ECH heating. Each kind of image implies the execution of different application software. Due to the fact that the recognition system is based on a learning system and major modifications have been carried out in both the diagnostic (optics) and TJ-II plasmas (injected power), the classifier model is no longer valid. A new SVM model has been developed with the current conditions. Also, specific error conditions in the data acquisition process can automatically be detected and managed now. The recovering process has been automated, thereby avoiding the loss of data in ensuing discharges.

  7. Ultrashort x-ray pulse generation by nonlinear Thomson scattering of a relativistic electron with an intense circularly polarized laser pulse

    Directory of Open Access Journals (Sweden)

    F. Liu

    2012-07-01

    Full Text Available The nonlinear Thomson scattering of a relativistic electron with an intense laser pulse is calculated numerically. The results show that an ultrashort x-ray pulse can be generated by an electron with an initial energy of 5 MeV propagating across a circularly polarized laser pulse with a duration of 8 femtosecond and an intensity of about 1.1×10^{21}  W/cm^{2}, when the detection direction is perpendicular to the propagation directions of both the electron and the laser beam. The optimal values of the carrier-envelop phase and the intensity of the laser pulse for the generation of a single ultrashort x-ray pulse are obtained and verified by our calculations of the radiation characteristics.

  8. The Kelvin-Thomson atom

    International Nuclear Information System (INIS)

    Walton, A.J.

    1977-01-01

    The examination of the contributions made by Kelvin and later by J.J. Thomson to knowledge of the structure of the atom, which was carried out in Pt. I of this article (Phys. Educ.; 12:326 (1977)), is here extended to the structure of atoms containing more than six electrons, the point at which Thomson's contribution becomes important. It is shown that it is possible to have a mechanically stable ring of more than three electrons provided the ring is rotating. Some properties predicted for elements in the Kelvin-Thomson model are also examined. (U.K.)

  9. Measurement of high-dynamic range x-ray Thomson scattering spectra for the characterization of nano-plasmas at LCLS

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, M. J., E-mail: macdonm@umich.edu [University of Michigan, Ann Arbor, Michigan 48109 (United States); SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Gorkhover, T. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Technische Universität, 10623 Berlin (Germany); Bachmann, B.; Hau-Riege, S. P.; Pardini, T.; Döppner, T. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Bucher, M. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Argonne National Lab, Lemont, Illinois 60439 (United States); Carron, S. [California Lutheran University, Thousand Oaks, California 91360 (United States); Coffee, R. N.; Fletcher, L. B.; Gamboa, E. J.; Glenzer, S. H.; Göde, S.; Krzywinski, J.; O’Grady, C. P.; Osipov, T.; Swiggers, M. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Drake, R. P. [University of Michigan, Ann Arbor, Michigan 48109 (United States); Ferguson, K. R. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Stanford University, Stanford, California 94305 (United States); Kraus, D. [University of California, Berkeley, California 94720 (United States); and others

    2016-11-15

    Atomic clusters can serve as ideal model systems for exploring ultrafast (∼100 fs) laser-driven ionization dynamics of dense matter on the nanometer scale. Resonant absorption of optical laser pulses enables heating to temperatures on the order of 1 keV at near solid density conditions. To date, direct probing of transient states of such nano-plasmas was limited to coherent x-ray imaging. Here we present the first measurement of spectrally resolved incoherent x-ray scattering from clusters, enabling measurements of transient temperature, densities, and ionization. Single shot x-ray Thomson scattering signals were recorded at 120 Hz using a crystal spectrometer in combination with a single-photon counting and energy-dispersive pnCCD. A precise pump laser collimation scheme enabled recording near background-free scattering spectra from Ar clusters with an unprecedented dynamic range of more than 3 orders of magnitude. Such measurements are important for understanding collective effects in laser-matter interactions on femtosecond time scales, opening new routes for the development of schemes for their ultrafast control.

  10. Ion temperature measurements of H-, D- and He-plasmas in the TCA tokamak by collective Thomson scattering of D2O laser radiation

    International Nuclear Information System (INIS)

    Behn, R.; Dicken, D.; Hackmann, J.; Salito, S.A.; Siegrist, M.R.

    1989-01-01

    Development of collective Thomson scattering as a method to measure the ion temperature of a tokamak plasma has been successful and encouraging results have been obtained during experiments on TCA in H-, D- and He-plasmas. Using a laser source in the far-infrared spectral region allows scattering angles close to 90 o , which results in excellent spatial resolution. The system installed on the TCA tokamak comprises an optically pumped D 2 O laser emitting 0.5 J in a 1.4 μs pulse on its Raman transition at 385μm. A heterodyne receiver with a Schottky barrier diode mixer has been chosen to detect the scattered radiation and analyze its spectral distribution in 12 channels of 80 MHz. Recent improvements of the mixer and 1st IF-amplifier yielded a system NEP of 2.2·10 -19 W/Hz. As a consequence we have obtained results which allow for the first time to evaluate the ion temperature T i in a single laser shot. (author) 3 figs., 1 tab

  11. Point sources and multipoles in inverse scattering theory

    CERN Document Server

    Potthast, Roland

    2001-01-01

    Over the last twenty years, the growing availability of computing power has had an enormous impact on the classical fields of direct and inverse scattering. The study of inverse scattering, in particular, has developed rapidly with the ability to perform computational simulations of scattering processes and led to remarkable advances in a range of applications, from medical imaging and radar to remote sensing and seismic exploration. Point Sources and Multipoles in Inverse Scattering Theory provides a survey of recent developments in inverse acoustic and electromagnetic scattering theory. Focusing on methods developed over the last six years by Colton, Kirsch, and the author, this treatment uses point sources combined with several far-reaching techniques to obtain qualitative reconstruction methods. The author addresses questions of uniqueness, stability, and reconstructions for both two-and three-dimensional problems.With interest in extracting information about an object through scattered waves at an all-ti...

  12. Comparing Two Approaches for Point-Like Scatterer Detection

    Directory of Open Access Journals (Sweden)

    Angela Dell’Aversano

    2015-01-01

    Full Text Available Many inverse scattering problems concern the detection and localisation of point-like scatterers which are sparsely enclosed within a prescribed investigation domain. Therefore, it looks like a good option to tackle the problem by applying reconstruction methods that are properly tailored for such a type of scatterers or that naturally enforce sparsity in the reconstructions. Accordingly, in this paper we compare the time reversal-MUSIC and the compressed sensing. The study develops through numerical examples and focuses on the role of noise in data and mutual coupling between the scatterers.

  13. SCAP-82, Single Scattering, Albedo Scattering, Point-Kernel Analysis in Complex Geometry

    International Nuclear Information System (INIS)

    Disney, R.K.; Vogtman, S.E.

    1987-01-01

    1 - Description of problem or function: SCAP solves for radiation transport in complex geometries using the single or albedo scatter point kernel method. The program is designed to calculate the neutron or gamma ray radiation level at detector points located within or outside a complex radiation scatter source geometry or a user specified discrete scattering volume. Geometry is describable by zones bounded by intersecting quadratic surfaces within an arbitrary maximum number of boundary surfaces per zone. Anisotropic point sources are describable as pointwise energy dependent distributions of polar angles on a meridian; isotropic point sources may also be specified. The attenuation function for gamma rays is an exponential function on the primary source leg and the scatter leg with a build- up factor approximation to account for multiple scatter on the scat- ter leg. The neutron attenuation function is an exponential function using neutron removal cross sections on the primary source leg and scatter leg. Line or volumetric sources can be represented as a distribution of isotropic point sources, with un-collided line-of-sight attenuation and buildup calculated between each source point and the detector point. 2 - Method of solution: A point kernel method using an anisotropic or isotropic point source representation is used, line-of-sight material attenuation and inverse square spatial attenuation between the source point and scatter points and the scatter points and detector point is employed. A direct summation of individual point source results is obtained. 3 - Restrictions on the complexity of the problem: - The SCAP program is written in complete flexible dimensioning so that no restrictions are imposed on the number of energy groups or geometric zones. The geometric zone description is restricted to zones defined by boundary surfaces defined by the general quadratic equation or one of its degenerate forms. The only restriction in the program is that the total

  14. Cooperative scattering of scalar waves by optimized configurations of point scatterers

    Science.gov (United States)

    Schäfer, Frank; Eckert, Felix; Wellens, Thomas

    2017-12-01

    We investigate multiple scattering of scalar waves by an ensemble of N resonant point scatterers in three dimensions. For up to N = 21 scatterers, we numerically optimize the positions of the individual scatterers, to maximize the total scattering cross section for an incoming plane wave, on the one hand, and to minimize the decay rate associated to a long-lived scattering resonance, on the other. In both cases, the optimum is achieved by configurations where all scatterers are placed on a line parallel to the direction of the incoming plane wave. The associated maximal scattering cross section increases quadratically with the number of scatterers for large N, whereas the minimal decay rate—which is realized by configurations that are not the same as those that maximize the scattering cross section—decreases exponentially as a function of N. Finally, we also analyze the stability of our optimized configurations with respect to small random displacements of the scatterers. These results demonstrate that optimized configurations of scatterers bear a considerable potential for applications such as quantum memories or mirrors consisting of only a few atoms.

  15. Critical points for electron–Mg atom elastic scattering

    Science.gov (United States)

    Kumar, Ashok; Kumar, Sunil; Rastogi, Nikhil; Raj, Deo

    2018-02-01

    The partial wave method, along with a central potential which includes the effects of static field, exchange, polarization, absorption and spin–orbit interaction, is employed to search the critical points for the elastic scattering of electrons from Mg atoms. A novel iterative procedure is developed to calculate the critical points. A pilot application is made for Mg atoms. The present investigation shows the existence of two critical point pairs (E c1 = 15.4484 eV, θ c1 = 56.930°) and (E c2 = 75.6175 eV, θ c2 = 104.261°) for the Mg atom. At critical energy E c2 and scattering angles 104.175° and 104.325°, 99% spin polarization of scattered electrons is obtained. To the best of our knowledge, no theoretical or experimental determination of critical points for the Mg (Z = 12) atom have yet been published.

  16. High resolution x-ray Thomson scattering measurements from cryogenic hydrogen jets using the linac coherent light source

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, L. B., E-mail: lbfletch@slac.stanford.edu; Galtier, E.; Gamboa, E. J.; Schumaker, W.; Gauthier, M.; Granados, E.; Lee, H. J.; Fry, A.; Kim, J. B.; Roedel, C.; Mishra, R.; Glenzer, S. H. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Zastrau, U. [European XFEL, Schenefeld (Germany); Goede, S. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); European XFEL, Schenefeld (Germany); Ravasio, A. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Laboratoire pour l’Utilisation des Lasers Intenses, Palaiseau Cedex (France); MacDonald, M. J. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); University of Michigan, Ann Arbor, Michigan 48109 (United States); Chen, Z. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); Pelka, A. [Helmholtz Zentrum Dresden-Rossendorf, Dresden (Germany); Kraus, D. [Helmholtz Zentrum Dresden-Rossendorf, Dresden (Germany); Department of Physics, University of California Berkeley, Berkeley, California 94720 (United States); Barbrel, B. [Department of Physics, University of California Berkeley, Berkeley, California 94720 (United States); and others

    2016-11-15

    We present the first spectrally resolved measurements of x-rays scattered from cryogenic hydrogen jets in the single photon counting limit. The 120 Hz capabilities of the LCLS, together with a novel hydrogen jet design [J. B. Kim et al., Rev. Sci. Instrum. (these proceedings)], allow for the ability to record a near background free spectrum. Such high-dynamic-range x-ray scattering measurements enable a platform to study ultra-fast, laser-driven, heating dynamics of hydrogen plasmas. This measurement has been achieved using two highly annealed pyrolytic graphite crystal spectrometers to spectrally resolve 5.5 keV x-rays elastically and inelastically scattered from cryogenic hydrogen and focused on Cornell-SLAC pixel array detectors [S. Herrmann et al., Nucl. Instrum. Methods Phys. Res., Sect. A 718, 550 (2013)].

  17. Measurement of electron density and electron temperature of a cascaded arc plasma using laser Thomson scattering compared to an optical emission spectroscopic approach

    Science.gov (United States)

    Yong, WANG; Cong, LI; Jielin, SHI; Xingwei, WU; Hongbin, DING

    2017-11-01

    As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering (LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5 × 1019 m-3 to 7.1 × 1020 m-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison, an optical emission spectroscopy (OES) system was established as well. The results showed that the electron excitation temperature (configuration temperature) measured by OES is significantly higher than the electron temperature (kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium (LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma.

  18. Profile measurements of the electron temperature on the ASDEX Upgrade, COMPASS, and ISTTOK tokamak using Thomson scattering, triple, and ball-pen probes.

    Science.gov (United States)

    Adamek, J; Müller, H W; Silva, C; Schrittwieser, R; Ionita, C; Mehlmann, F; Costea, S; Horacek, J; Kurzan, B; Bilkova, P; Böhm, P; Aftanas, M; Vondracek, P; Stöckel, J; Panek, R; Fernandes, H; Figueiredo, H

    2016-04-01

    The ball-pen probe (BPP) technique is used successfully to make profile measurements of the electron temperature on the ASDEX Upgrade (Axially Symmetric Divertor Experiment), COMPASS (COMPact ASSembly), and ISTTOK (Instituto Superior Tecnico TOKamak) tokamak. The electron temperature is provided by a combination of the BPP potential (ΦBPP) and the floating potential (Vfl) of the Langmuir probe (LP), which is compared with the Thomson scattering diagnostic on ASDEX Upgrade and COMPASS. Excellent agreement between the two diagnostics is obtained for circular and diverted plasmas and different heating mechanisms (Ohmic, NBI, ECRH) in deuterium discharges with the same formula Te = (ΦBPP - Vfl)/2.2. The comparative measurements of the electron temperature using BPP/LP and triple probe (TP) techniques on the ISTTOK tokamak show good agreement of averaged values only inside the separatrix. It was also found that the TP provides the electron temperature with significantly higher standard deviation than BPP/LP. However, the resulting values of both techniques are well in the phase with the maximum of cross-correlation function being 0.8.

  19. Profile measurements of the electron temperature on the ASDEX Upgrade, COMPASS, and ISTTOK tokamak using Thomson scattering, triple, and ball-pen probes

    International Nuclear Information System (INIS)

    Adamek, J.; Horacek, J.; Bilkova, P.; Böhm, P.; Aftanas, M.; Vondracek, P.; Stöckel, J.; Panek, R.; Müller, H. W.; Silva, C.; Fernandes, H.; Figueiredo, H.; Schrittwieser, R.; Ionita, C.; Mehlmann, F.; Costea, S.; Kurzan, B.

    2016-01-01

    The ball-pen probe (BPP) technique is used successfully to make profile measurements of the electron temperature on the ASDEX Upgrade (Axially Symmetric Divertor Experiment), COMPASS (COMPact ASSembly), and ISTTOK (Instituto Superior Tecnico TOKamak) tokamak. The electron temperature is provided by a combination of the BPP potential (Φ BPP ) and the floating potential (V fl ) of the Langmuir probe (LP), which is compared with the Thomson scattering diagnostic on ASDEX Upgrade and COMPASS. Excellent agreement between the two diagnostics is obtained for circular and diverted plasmas and different heating mechanisms (Ohmic, NBI, ECRH) in deuterium discharges with the same formula T e = (Φ BPP − V fl )/2.2. The comparative measurements of the electron temperature using BPP/LP and triple probe (TP) techniques on the ISTTOK tokamak show good agreement of averaged values only inside the separatrix. It was also found that the TP provides the electron temperature with significantly higher standard deviation than BPP/LP. However, the resulting values of both techniques are well in the phase with the maximum of cross-correlation function being 0.8.

  20. Profile measurements of the electron temperature on the ASDEX Upgrade, COMPASS, and ISTTOK tokamak using Thomson scattering, triple, and ball-pen probes

    Science.gov (United States)

    Adamek, J.; Müller, H. W.; Silva, C.; Schrittwieser, R.; Ionita, C.; Mehlmann, F.; Costea, S.; Horacek, J.; Kurzan, B.; Bilkova, P.; Böhm, P.; Aftanas, M.; Vondracek, P.; Stöckel, J.; Panek, R.; Fernandes, H.; Figueiredo, H.

    2016-04-01

    The ball-pen probe (BPP) technique is used successfully to make profile measurements of the electron temperature on the ASDEX Upgrade (Axially Symmetric Divertor Experiment), COMPASS (COMPact ASSembly), and ISTTOK (Instituto Superior Tecnico TOKamak) tokamak. The electron temperature is provided by a combination of the BPP potential (ΦBPP) and the floating potential (Vfl) of the Langmuir probe (LP), which is compared with the Thomson scattering diagnostic on ASDEX Upgrade and COMPASS. Excellent agreement between the two diagnostics is obtained for circular and diverted plasmas and different heating mechanisms (Ohmic, NBI, ECRH) in deuterium discharges with the same formula Te = (ΦBPP - Vfl)/2.2. The comparative measurements of the electron temperature using BPP/LP and triple probe (TP) techniques on the ISTTOK tokamak show good agreement of averaged values only inside the separatrix. It was also found that the TP provides the electron temperature with significantly higher standard deviation than BPP/LP. However, the resulting values of both techniques are well in the phase with the maximum of cross-correlation function being 0.8.

  1. Scattering analysis of point processes and random measures

    International Nuclear Information System (INIS)

    Hanisch, K.H.

    1984-01-01

    In the present paper scattering analysis of point processes and random measures is studied. Known formulae which connect the scattering intensity with the pair distribution function of the studied structures are proved in a rigorous manner with tools of the theory of point processes and random measures. For some special fibre processes the scattering intensity is computed. For a class of random measures, namely for 'grain-germ-models', a new formula is proved which yields the pair distribution function of the 'grain-germ-model' in terms of the pair distribution function of the underlying point process (the 'germs') and of the mean structure factor and the mean squared structure factor of the particles (the 'grains'). (author)

  2. Application of Thomson scattering at 1.06{mu}m as a diagnostic for spatial profile measurements of electron temperature and density on the TCV tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Franke, S. [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP)

    1997-04-01

    The variable configuration tokamak, TCV, in operation at CRPP since the end of 1991, is a particularly challenging machine with regard to the experimental system that must provide essential information regarding properties of confined plasmas with strongly shaped, non-circular cross-sections. The importance of the energy confinement issue in a machine designed specifically for the investigation of the effect of plasma shape on confinement and stability is self-evident, as is the necessity for a diagnostic capable of providing the profiles of electron temperature and density required for evaluation of this confinement. For TCV, a comprehensive Thomson Scattering (TS) diagnostic was the natural choice, specifically owing to the resulting spatially localized and time resolved measurement. The details of the system installed on TCV, together with the results obtained from the diagnostic comprise the subject matter of this thesis. A first version of the diagnostic was equipped with only ten observation volumes. In this case, adequate spatial resolution can only be maintained if measurements are limited to plasmas located in the upper half of the highly elongated TCV vacuum vessel. The system has recently been upgraded through the addition of a further fifteen observation volumes, together with major technical improvements in the scattered light detection system. This new version now permits TS observations in all TCV plasma configurations, including equilibria produced in the lower and upper halves of the vacuum vessel and the highly elongated plasmas now routinely created. Whilst a description of the new detection system along with some results obtained using the extended set of observation volumes are included, this thesis reports principally on the hardware details of and the interpretation of data from the original, ten observation volume system. (author) figs., tabs., 75 refs.

  3. Application of Thomson scattering at 1.06μm as a diagnostic for spatial profile measurements of electron temperature and density on the TCV tokamak

    International Nuclear Information System (INIS)

    Franke, S.

    1997-04-01

    The variable configuration tokamak, TCV, in operation at CRPP since the end of 1991, is a particularly challenging machine with regard to the experimental system that must provide essential information regarding properties of confined plasmas with strongly shaped, non-circular cross-sections. The importance of the energy confinement issue in a machine designed specifically for the investigation of the effect of plasma shape on confinement and stability is self-evident, as is the necessity for a diagnostic capable of providing the profiles of electron temperature and density required for evaluation of this confinement. For TCV, a comprehensive Thomson Scattering (TS) diagnostic was the natural choice, specifically owing to the resulting spatially localized and time resolved measurement. The details of the system installed on TCV, together with the results obtained from the diagnostic comprise the subject matter of this thesis. A first version of the diagnostic was equipped with only ten observation volumes. In this case, adequate spatial resolution can only be maintained if measurements are limited to plasmas located in the upper half of the highly elongated TCV vacuum vessel. The system has recently been upgraded through the addition of a further fifteen observation volumes, together with major technical improvements in the scattered light detection system. This new version now permits TS observations in all TCV plasma configurations, including equilibria produced in the lower and upper halves of the vacuum vessel and the highly elongated plasmas now routinely created. Whilst a description of the new detection system along with some results obtained using the extended set of observation volumes are included, this thesis reports principally on the hardware details of and the interpretation of data from the original, ten observation volume system. (author) figs., tabs., 75 refs

  4. NESKA, Electron and Positron Scattering from Point Nuclei

    International Nuclear Information System (INIS)

    Idoeta, R.; Legarda, F.

    2002-01-01

    1 - Description of program or function: The Mott's differential cross section for the scattering of electrons and positrons by point nuclei without screening is calculated for any energy, atomic number and angle of scattering. 2 - Method of solution: We have summed the conditionally convergent series appearing in Mott's cross section using two consecutive transformations: the one of Yennie, Ravenhall and Wilson and that of Euler till we have seven times six significant figures repeated in the ratio of the Mott cross section to the classical Rutherford cross section. 3 - Restrictions on the complexity of the problem: Those appearing in the use of Mott's cross section for unscreened point nuclei

  5. Alpha particle kinetics in ignited fusion plasmas: Design applications for a CO2 laser Thomson scattering experiment

    Science.gov (United States)

    Bennett, C. A.

    1994-05-01

    Technical achievements during the initial budget phase of this study consists of work accomplished under the following categories: (1) Hot Cell Notch Filter; and (2) System Integration. In the two week period just prior to the 1993 shutdown of ATF, the authors were able to make the planned scattering measurement. The experiment was a complete success, and the feasibility of the approach was unambiguously demonstrated. The measurements have been reported in a separate article.

  6. Optical properties of two-dimensional magnetoelectric point scattering lattices

    DEFF Research Database (Denmark)

    Hansen, Per Lunnemann; Sersic, Ivana; Koenderink, A. Femius

    2013-01-01

    We explore the electrodynamic coupling between a plane wave and an infinite two-dimensional periodic lattice of magnetoelectric point scatterers, deriving a semianalytical theory with consistent treatment of radiation damping, retardation, and energy conservation. We apply the theory to arrays...

  7. Rothmund - Thomson Syndrome

    Directory of Open Access Journals (Sweden)

    Sharma N. L

    2003-01-01

    Full Text Available Rothmund-Thomson syndrome is a rare geno-photodermatosis of children. Poikilodermatous cutaneous changes, growth retardation, juvenile cataract and high incidence of malignancy are its classical features. A Thomson type of Rothmund-Thomson syndrome with characteristic poikiloderma congenitale, growth retardation, absence of juvenile cataract and parental non-consanguinity is described in an 8 year old Indian girl.

  8. Spin wave vortex from the scattering on Bloch point solitons

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho-Santos, V.L., E-mail: vagson.carvalho@usach.cl [Instituto Federal de Educação, Ciência e Tecnologia Baiano - Campus Senhor do Bonfim, Km 04 Estrada da Igara, 48970-000 Senhor do Bonfim, Bahia (Brazil); Departamento de Física, Universidad de Santiago de Chile and CEDENNA, Avda. Ecuador 3493, Santiago (Chile); Elías, R.G., E-mail: gabriel.elias@usach.cl [Departamento de Física, Universidad de Santiago de Chile and CEDENNA, Avda. Ecuador 3493, Santiago (Chile); Nunez, A.S., E-mail: alnunez@dfi.uchile.cl [Departamento de Física, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Casilla 487-3, Santiago (Chile)

    2015-12-15

    The interaction of a spin wave with a stationary Bloch point is studied. The topological non-trivial structure of the Bloch point manifests in the propagation of spin waves endowing them with a gauge potential that resembles the one associated with the interaction of a magnetic monopole and an electron. By pursuing this analogy, we are led to the conclusion that the scattering of spin waves and Bloch points is accompanied by the creation of a magnon vortex. Interference between such a vortex and a plane wave leads to dislocations in the interference pattern that can be measurable by means of magnon holography.

  9. Disappearance of the laue spots of the downward X-ray diffraction and huge recoil Thomson scattering in solid helium as some prominent peculiarities of a quantum crystal

    International Nuclear Information System (INIS)

    Nakajima, Tetsuo.

    1996-02-01

    In topographs of the downward X-ray diffraction, no Laue spots could be observed using a horizontally thin line-focussed beam. The disappearance of the Laue spots by the downward X-ray diffraction could be explained by two main factors besides a synergistic effect of the smallness of the atomic-scattering factors, the absorption coefficients, the densities etc. One is that the downward X-ray diffraction is completely inelastic scattering, and, as a result, diffracted X-ray beams may become entirely diffuse scattering. The other is that the great difference in the linear scatterer density between the forward and downward directions resulted from the fact that the irradiation of a line-focussed X-ray beam to take section topographs weakens the downward X-ray diffraction. The main reason is not due to the zero-point vibration. (J.P.N.)

  10. Application of virtual machine technology to real-time mapping of Thomson scattering data to flux coordinates for the LHD

    Energy Technology Data Exchange (ETDEWEB)

    Emoto, Masahiko, E-mail: emoto.masahiko@nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki city, 509-5292 Japan (Japan); Yoshida, Masanobu; Suzuki, Chihiro; Suzuki, Yasuhiro; Ida, Katsumi; Nagayama, Yoshio; Akiyama, Tsuyoshi; Kawahata, Kazuo; Narihara, Kazumichi; Tokuzawa, Tokihiko; Yamada, Ichihiro [National Institute for Fusion Science, 322-6 Oroshi, Toki city, 509-5292 Japan (Japan)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We have developed a mapping system of the electron temperature profile to the flux coordinates. Black-Right-Pointing-Pointer To increases the performance, multiple virtual machines are used. Black-Right-Pointing-Pointer The virtual machine technology is flexible when increasing the number of computers. - Abstract: This paper presents a system called 'TSMAP' that maps electron temperature profiles to flux coordinates for the Large Helical Device (LHD). Considering the flux surface is isothermal, TSMAP searches an equilibrium database for the LHD equilibrium that fits the electron temperature profile. The equilibrium database is built through many VMEC computations of the helical equilibria. Because the number of equilibria is large, the most important technical issue for realizing the TSMAP system is computational performance. Therefore, we use multiple personal computers to enhance performance when building the database for TSMAP. We use virtual machines on multiple Linux computers to run the TSMAP program. Virtual machine technology is flexible, allowing the number of computers to be easily increased. This paper discusses how the use of virtual machine technology enhances the performance of TSMAP calculations when multiple CPU cores are used.

  11. Unidirectional emission from circular dielectric microresonators with a point scatterer

    International Nuclear Information System (INIS)

    Dettmann, C. P.; Morozov, G. V.; Sieber, M.; Waalkens, H.

    2009-01-01

    Circular microresonators are micron-sized dielectric disks embedded in material of lower refractive index. They possess modes of extremely high Q-factors (low-lasing thresholds), which makes them ideal candidates for the realization of miniature laser sources. They have, however, the disadvantage of isotropic light emission caused by the rotational symmetry of the system. In order to obtain high directivity of the emission while retaining high Q-factors, we consider a microdisk with a pointlike scatterer placed off-center inside of the disk. We calculate the resulting resonant modes and show that some of them possess both of the desired characteristics. The emission is predominantly in the direction opposite to the scatterer. We show that classical ray optics is a useful guide to optimizing the design parameters of this system. We further find that exceptional points in the resonance spectrum influence how complex resonance wave numbers change if system parameters are varied.

  12. measurements by Thomson scattering system

    Indian Academy of Sciences (India)

    major radius (R) of 75 cm, minor radius (o) of 25 cm, plasma current (БФ) of ~250 kA, electron density <5 x10Ѕїcm .... assure maximum transmission. The PMTs are gated and are triggered by the output of a fast photo-diode which receives a portion of the laser beam before entering into the plasma. 4. Operational testing and ...

  13. Experimentally-based ExB drifts in the DIII-D divertor and SOL calculated from integration of Ohm's law using Thomson scattering measurements of Te and ne

    Directory of Open Access Journals (Sweden)

    P.C. Stangeby

    2017-08-01

    Full Text Available The 2D spatial distributions of cross field drift velocities are calculated from 2D Thomson scattering measurements of Te and ne in the divertor and SOL of DIII-D. In contrast with the method that has been used on DIII-D where the 2D distribution of plasma potential Vplasma is obtained from measurements of the probe floating potential of reciprocating probes, the present method does not require insertion of a probe into the plasma and can therefore be used in high power discharges. The 2D spatial distribution of Vplasma is calculated from Ohm's Law for the parallel electric field E|| along each flux tube, E∥(s∥=−1.71dTe/ds∥−(Te/nedne/ds∥, where the Thomson scattering values of Te and ne are used. To within a constant of integration, Vplasma is obtained by integrating E|| along the flux-tubes (field lines; the constant is obtained for each flux tube using the sheath drop at the target calculated from the characteristic of Langmuir probes built into the divertor tiles. The 2D distributions of Eradial=−dVp/dsradial, Epoloidal=−dVp/dspoloidal, vExBpoloidal=Eradial/B and vExBradial=Epoloidal/B are then calculated as well as the particle drift flux densities ΓExBpoloidal=nvExBpoloidal and ΓExBradial=nvExBradial for electrons, fuel ions and impurity ions, using the appropriate values of particle density, n.

  14. Flow speed measurement using two-point collective light scattering

    International Nuclear Information System (INIS)

    Heinemeier, N.P.

    1998-09-01

    Measurements of turbulence in plasmas and fluids using the technique of collective light scattering have always been plagued by very poor spatial resolution. In 1994, a novel two-point collective light scattering system for the measurement of transport in a fusion plasma was proposed. This diagnostic method was design for a great improvement of the spatial resolution, without sacrificing accuracy in the velocity measurement. The system was installed at the W7-AS steallartor in Garching, Germany, in 1996, and has been operating since. This master thesis is an investigation of the possible application of this new method to the measurement of flow speeds in normal fluids, in particular air, although the results presented in this work have significance for the plasma measurements as well. The main goal of the project was the experimental verification of previous theoretical predictions. However, the theoretical considerations presented in the thesis show that the method can only be hoped to work for flows that are almost laminar and shearless, which makes it of very small practical interest. Furthermore, this result also implies that the diagnostic at W7-AS cannot be expected to give the results originally hoped for. (au)

  15. Oscillations in the spectrum of nonlinear Thomson-backscattered radiation

    Directory of Open Access Journals (Sweden)

    C. A. Brau

    2004-02-01

    Full Text Available When an electron beam collides with a high-intensity laser beam, the spectrum of the nonlinear Thomson scattering in the backward direction shows strong oscillations like those in the spectrum of an optical klystron. Laser gain on the backward Thomson scattering is estimated using the Madey theorem, and the results suggest that Thomson-backscatter free-electron lasers are possible at wavelengths extending to the far uv using a terawatt laser beam from a chirped-pulse amplifier and a high-brightness electron beam from a needle cathode.

  16. Development of an Internet-Enabled Tool for NSTX-U Thomson Diagnostic Data

    Science.gov (United States)

    Wallace, William; Diallo, Ahmed

    2016-10-01

    MultiPoint Thomson Scattering (MPTS) is an established, accurate method of finding the temperature, density, and pressure of a magnetically confined plasma. Two Nd:YAG (1064 nm) lasers are fired into the plasma with a effective frequency of 60 Hz, and the light is Doppler shifted by Thomson scattering. Polychromators on the NSTX-U midplane collect the scattered photons at various radii/scattering angles, and the avalanche photodiode voltages are saved to an MDSplus tree for later analysis. IDL code is then used to determine plasma temperature, pressure, and density from the captured polychromator measurements via Selden formulas.[1] OMFIT, from the General Atomics Fusion Theory Team, is a rich data workflow package used on DIII-D, NSTX-U, and other experiments to rapidly investigate and draw conclusions from collated data sets and simulations. OMFIT can also be used as a data access source into other toolkits and fusion analysis software. This project, written in Python and taking advantage of late-generation Internet software technologies, uses OMFIT to rapidly find and visualize Thomson diagnostic plasma characteristics enabling scientists to gain a quick understanding of shot behavior and timeframes.

  17. EDITORIAL: J J Thomson's Electron

    Science.gov (United States)

    Adams, Steve

    1997-07-01

    . One of the greatest of these was Paul Dirac, a marvellously reticent man with an eye for mathematical beauty. David Miller, one of the winners of William Waldegrave's 'Higgs Challenge' in 1993, shows how Dirac constructed his famous equation, and how it describes the behaviour of the electron and its neutrino and led to the prediction of antimatter and the explanation of spin. He draws an interesting parallel between Dirac's negative energy electrons and the contemporary development of solid state physics. G P Thomson, JJ's son, also got in on the act: father got the Nobel Prize (1906) for showing the electron is a particle and son (1937) won it for showing it also behaves like a wave! This has had a profound impact both on the interpretation and experimental testing of quantum theory and in the way we use electrons. Electron waves are essential to understand solid state physics and wave-like properties are fundamental to the behaviour of many electronic devices. But it is not just in physics and electronics that the electron has been revolutionary, and John Squire's article reviews the use of the electron microscope in biology. Having crossed the border into biology (as so many physicists have done this century) it should be pointed out that electron physics also caused a paradigm shift in chemistry. Electronic structure made the Periodic Table comprehensible and led to a theory of bonding that accounts for the mechanical, electrical and optical properties of many materials. This is described in Peter Hughes's article. Which brings me back to JJT and those sound-bites, and the Royal Institution for that matter.... On 10 March 1905 JJT gave another of his Friday Evening Discourses. This one was called 'The Structure of the Atom'. In it he developed a model suggested by Lord Kelvin, in which negative corpuscles arrange themselves in a stable configuration within a sphere of positively charged fluid. This is the infamous `plum pudding'. There is not room to go into

  18. Rothmund-Thomson Syndrome

    DEFF Research Database (Denmark)

    Suter, Aude-Annick; Itin, Peter; Heinimann, Karl

    2016-01-01

    BACKGROUND: Poikiloderma is defined as a chronic skin condition presenting with a combination of punctate atrophy, areas of depigmentation, hyperpigmentation and telangiectasia. In a variety of hereditary syndromes such as Rothmund-Thomson syndrome (RTS), Clericuzio-type poikiloderma...

  19. Chaotic scattering of two identical point vortex pairs revisited

    DEFF Research Database (Denmark)

    Tophøj, Laust Emil Hjerrild; Aref, Hassan

    2008-01-01

    unstable periodic solutions similar to those seen in the thereby associated three-vortex problems. The integrals of motion, linear impulse and Hamiltonian are recast in a form appropriate for vortex pair scattering interactions that provides constraints on the parameters characterizing the outgoing vortex...

  20. Leiper, Prof. Robert Thomson

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1938 Honorary. Leiper, Prof. Robert Thomson. Date of birth: 17 April 1881. Date of death: 21 May 1969. YouTube; Twitter; Facebook; Blog. Academy News. IAS Logo. Theory Of Evolution. Posted on 23 January 2018. Joint Statement by the Three Science Academies of India on the ...

  1. Continued Development of Python-Based Thomson Data Analysis and Associated Visualization Tool for NSTX-U

    Science.gov (United States)

    Wallace, William; Miller, Jared; Diallo, Ahmed

    2015-11-01

    MultiPoint Thomson Scattering (MPTS) is an established, accurate method of finding the temperature, density, and pressure of a magnetically confined plasma. Two Nd:YAG (1064 nm) lasers are fired into the plasma with a effective frequency of 60 Hz, and the light is Doppler shifted by Thomson scattering. Polychromators on the NSTX-U midplane collect the scattered photons at various radii/scattering angles, and the avalanche photodiode voltages are saved to an MDSplus tree for later analysis. IDL code is then used to determine plasma temperature, pressure, and density from the captured polychromator measurements via Selden formulas. [1] Previous work [2] converted the single-processor IDL code into Python code, and prepared a new architecture for multiprocessing MPTS in parallel. However, that work was not completed to the generation of output data and curve fits that match with the previous IDL. This project refactored the Python code into a object-oriented architecture, and created a software test suite for the new architecture which allowed identification of the code which generated the difference in output. Another effort currently underway is to display the Thomson data in an intuitive, interactive format. This work was supported in part by the U.S. Department of Energy, Office of Science, Office of Workforce Development for Teachers and Scientists (WDTS) under the Community College Internship (CCI) program.

  2. REACHING ULTRA HIGH PEAK CHARACTERISTICS IN RELATIVISTIC THOMSON BACKSCATTERING

    International Nuclear Information System (INIS)

    POGORELSKY, I.V.; BEN ZVI, I.; HIROSE, T.; KASHIWAGI, S.; YAKIMENKO, V.; KUSCHE, K.; SIDDONS, P.; ET AL

    2001-01-01

    The concept of x-ray laser synchrotron sources (LSS) based on Thomson scattering between laser photons and relativistic electrons leads to future femtosecond light-source facilities fit to multidisciplinary research in ultra-fast structural dynamics. Enticed by these prospects, the Brookhaven Accelerator Test Facility (ATF) embarked into development of the LSS based on a combination of a photocathode RF linac and a picosecond CO 2 laser. We observed the record 1.7 x 10 8 x-ray photons/pulse yield generated via relativistic Thomson scattering between the 14 GW CO 2 laser and 60 MeV electron beam

  3. The SPARC-LAB Thomson source

    Energy Technology Data Exchange (ETDEWEB)

    Vaccarezza, C., E-mail: cristina.vaccarezza@lnf.infn.it [INFN-LNF, Via Enrico Fermi, 40 00044 Frascati, Rome (Italy); Alesini, D.; Anania, M.P. [INFN-LNF, Via Enrico Fermi, 40 00044 Frascati, Rome (Italy); Bacci, A. [INFN-MI, Via Celoria 16, 20133 Milan (Italy); Biagioni, A.; Bisesto, F.; Bellaveglia, M. [INFN-LNF, Via Enrico Fermi, 40 00044 Frascati, Rome (Italy); Cardarelli, P. [University of Ferrara and INFN-FE, via Saragat 1, 44122 Ferrara (Italy); Cardelli, F. [University La Sapienza and INFN-Roma1, Piazzale Aldo Moro, 2 00161 Rome (Italy); Cianchi, A. [University of Rome Tor Vergata, Via della Ricerca Scientifica 1, 00133 Rome (Italy); Chiadroni, E.; Croia, M.; Curcio, A. [INFN-LNF, Via Enrico Fermi, 40 00044 Frascati, Rome (Italy); Delogu, P. [University of Pisa and INFN-PI, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Giovenale, D. Di [INFN-LNF, Via Enrico Fermi, 40 00044 Frascati, Rome (Italy); Domenico, G. Di [University of Ferrara and INFN-FE, via Saragat 1, 44122 Ferrara (Italy); Pirro, G. Di [INFN-LNF, Via Enrico Fermi, 40 00044 Frascati, Rome (Italy); Drebot, I. [INFN-MI, Via Celoria 16, 20133 Milan (Italy); Ferrario, M. [INFN-LNF, Via Enrico Fermi, 40 00044 Frascati, Rome (Italy); Filippi, F. [University La Sapienza and INFN-Roma1, Piazzale Aldo Moro, 2 00161 Rome (Italy); and others

    2016-09-01

    The SPARC-LAB Thomson source is a compact X-ray source based on the Thomson backscattering process presently under its second phase of commissioning at the LNF. The electron beam energy ranges between 30 and 150 MeV, the electrons collide head-on with the Ti:Sapphire FLAME laser pulse the energy of which ranges between 1 and 5 J with pulse lengths in the 25 fs–10 ps range, this provides an X-ray energy tunability in the range of 20–500 keV, with the further capability to generate strongly non-linear phenomena and to drive diffusion processes due to multiple and plural scattering effects. The experimental results of the obtained X-ray radiation are presented.

  4. Scattering of point particles by black holes: Gravitational radiation

    Science.gov (United States)

    Hopper, Seth; Cardoso, Vitor

    2018-02-01

    Gravitational waves can teach us not only about sources and the environment where they were generated, but also about the gravitational interaction itself. Here we study the features of gravitational radiation produced during the scattering of a pointlike mass by a black hole. Our results are exact (to numerical error) at any order in a velocity expansion, and are compared against various approximations. At large impact parameter and relatively small velocities our results agree to within percent level with various post-Newtonian and weak-field results. Further, we find good agreement with scaling predictions in the weak-field/high-energy regime. Lastly, we achieve striking agreement with zero-frequency estimates.

  5. Rothmund-Thomson Syndrome

    DEFF Research Database (Denmark)

    Suter, Aude-Annick; Itin, Peter; Heinimann, Karl

    2016-01-01

    with neutropenia (PN) and Dyskeratosis Congenita (DC), poikiloderma occurs as one of the main symptoms. Here, we report on genotype and phenotype data of a cohort of 44 index patients with RTS or related genodermatoses. METHODS: DNA samples from 43 patients were screened for variants in the 21 exons of the RECQL4...... to assess the patients' cancer risk, to avoid continuous and inconclusive clinical evaluations and to clarify the recurrence risk in the families. Additionally, it shows that the phenotype of more than 50% of the patients with suspected Rothmund-Thomson disease may be due to mutations in other genes raising...

  6. Bobina de Thomson

    Directory of Open Access Journals (Sweden)

    Horacio Munguía Aguilar

    2014-12-01

    Full Text Available Uno de los instrumentos más didácticos en la enseñanza de las leyes del electromagnetismo es la denominada Bobina de Thomson. Con ella se pueden realizar diferentes experimentos sobre las leyes de Ampere y Faraday. En el presente trabajo se muestra su funcionamiento, se explica el mecanismo de levitación del anillo de inducción, se presenta los detalles de un modelo construido y se mencionan otros experimentos que enriquecen su funcionalidad.

  7. Rothmund-thomson Syndrome

    Directory of Open Access Journals (Sweden)

    M Z Mani

    1979-01-01

    Full Text Available A case of Rothmund-Thomson syndrome in an 8-year-old Indian male is reported. The patient had bilaterally symmertrical superficial pigmentary deposition of thin nebulae in the lower one-third of the cornea and oonjunctiva. Urinary togmphy rcvmw a dibasic aininoacid with excretion of arginine, lysine;.hmncicystine and glycine. Other features of interest in this patient were onset at the age of 8 days and start of the disease on the hands and feet rather than face. The patient also developed repeated ulcerations on the hands and feet subsequent to minor trauma.

  8. A novel array processing method for precise depth detection of ultrasound point scatter

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Dalgarno, Paul A.; Greenaway, Alan H.

    2016-01-01

    simulation software. A 7 MHz linear transducer is used to scan a single point scatterer phantom that can move in the axial direction. Individual beamformer outputs from 3 different foci are post-processed using the highly-dependent on focusing errors, metric of sharpness to estimate the position of the point...

  9. Ab initio phonon point defect scattering and thermal transport in graphene

    Science.gov (United States)

    Polanco, Carlos A.; Lindsay, Lucas

    2018-01-01

    We study the scattering of phonons from point defects and their effect on lattice thermal conductivity κ using a parameter-free ab initio Green's function methodology. Specifically, we focus on the scattering of phonons by boron (B), nitrogen (N), and phosphorus substitutions as well as single- and double-carbon vacancies in graphene. We show that changes of the atomic structure and harmonic interatomic force constants locally near defects govern the strength and frequency trends of the scattering of out-of-plane acoustic (ZA) phonons, the dominant heat carriers in graphene. ZA scattering rates due to N substitutions are nearly an order of magnitude smaller than those for B defects despite having similar mass perturbations. Furthermore, ZA phonon scattering rates from N defects decrease with increasing frequency in the lower-frequency spectrum in stark contrast to expected trends from simple models. ZA phonon-vacancy scattering rates are found to have a significantly softer frequency dependence (˜ω0 ) in graphene than typically employed in phenomenological models. The rigorous Green's function calculations demonstrate that typical mass-defect models do not adequately describe ZA phonon-defect scattering rates. Our ab initio calculations capture well the trend of κ vs vacancy density from experiments, though not the magnitudes. This work elucidates important insights into phonon-defect scattering and thermal transport in graphene, and demonstrates the applicability of first-principles methods toward describing these properties in imperfect materials.

  10. Swiftly moving focus points and forming shapes through the scattering media

    Science.gov (United States)

    Tran, Vinh; Sahoo, Sujit Kumar; Tang, Dongliang; Dang, Cuong

    2018-02-01

    Propagation of light through scattering media such as ground glass or biological tissue limits the quality and intensity of focusing point. Wave front shaping technique which uses spatial light modulator (SLM) devices to reshape the field profile of incoming light, is considered as one of the most effective and convenient methods. Advanced biomedical or manufacturing applications require drawing various contours or shapes quickly and precisely. However, creating each shape behind the scattering medium needs different phase profiles, which are time consuming to optimize or measure. Here, we demonstrate a technique to draw various shapes or contours behind the scattering medium by swiftly moving the focus point without any mechanical movements. Our technique relies on the existence of speckle correlation property in scattering media, also known as optical memory effect. In our procedure, we first modulate the phase-only SLM to create the focus point on the other side of scattering medium. Then, we digitally shift the preoptimized phase profile on the SLM and ramp it to tilt the beam accordingly. Now, the incoming beam with identical phase profile shines on the same scattering region at a tilted angle to regenerate the focus point at the desired position due to memory effect. Moreover, with linear combination of different field patterns, we can generate a single phase profile on SLM to produce two, three or more focus points simultaneously on the other side of a turbid medium. Our method could provide a useful tool for prominent applications such as opto-genetic excitation, minimally invasive laser surgery and other related fields.

  11. Scattering in a Coulomb potential: a velocity space point of view

    International Nuclear Information System (INIS)

    Gonzalez V, A.; Guillaumin E, E.; Nunez Y, H.N.; Salas B, A.L.

    1998-01-01

    The unbounded motion of a particle in a Coulomb field is analyzed from the point of view of velocity space using both the hodograph and the properties of the Hamilton vector. Many features of the motion even the classical deflection function and the differential scattering cross section in velocity space follow from simple geometrical considerations, the standard Rutherford scattering formula in configuration space can then be simply obtained from them. We address the connection between initial conditions and the properties of the scattering orbits with the help of the Hamilton vector. We also discuss an approximate method for calculating the effect of a central perturbation on the properties of the hodograph and on the Rutherford differential scattering cross section. (Author)

  12. Scaling Thomson scattering to big machines

    Czech Academy of Sciences Publication Activity Database

    Bílková, Petra; Walsh, M.; Böhm, Petr; Bassan, M.; Aftanas, Milan; Pánek, Radomír

    2016-01-01

    Roč. 11, č. 3 (2016), C03023 ISSN 1748-0221. [International Symposium on Laser-Aided Plasma Diagnostics/17./. Sapporo, 27.09.2015-01.10.2015] Institutional support: RVO:61389021 Keywords : Spectrometers * Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - interferometry * Spectroscopy and imaging Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/11/03/C03023/pdf

  13. Scaling Thomson scattering to big machines

    Czech Academy of Sciences Publication Activity Database

    Bílková, Petra; Walsh, M.; Böhm, Petr; Bassan, M.; Aftanas, Milan; Pánek, Radomír

    2016-01-01

    Roč. 11, č. 3 (2016), č. článku C03302. ISSN 1748-0221. [International Symposium on Laser-Aided Plasma Diagnostics/17./. Sapporo, 27.09.2015-01.10.2015] Institutional support: RVO:61389021 Keywords : Spectrometers * Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - interferometry * Spectroscopy and imaging Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/11/03/C03023/pdf

  14. ITER Fast Ion Collective Thomson Scattering

    DEFF Research Database (Denmark)

    Bindslev, Henrik; Meo, Fernando; Korsholm, Søren Bang

    for measurements of the confined fusion alpha particles in ITER set by the ITER team. Then we outline the considerations, which enter into the selection and evaluation of CTS systems. System definition includes choice of probe frequency, geometry of probe and receiver beam patterns and probe power, but ultimately...

  15. Branch Point Withdrawal in Elongational Startup Flow by Time-Resolved Small Angle Neutron Scattering

    KAUST Repository

    Ruocco, N.

    2016-05-27

    We present a small angle neutron scattering (SANS) investigation of a blend composed of a dendritic polymer and a linear matrix with comparable viscosity in start-up of an elongational flow at Tg + 50. The two-generation dendritic polymer is diluted to 10% by weight in a matrix of a long well-entangled linear chains. Both components consist of mainly 1,4-cis-polyisoprene but differ in isotopic composition. The resulting scattering contrast is sufficiently high to permit time-resolved measurements of the system structure factor during the start-up phase and to follow the retraction processes involving the inner sections of the branched polymer in the nonlinear deformation response. The outer branches and the linear matrix, on the contrary, are in the linear deformation regime. The linear matrix dominates the rheological signature of the blend and the influence of the branched component can barely be detected. However, the neutron scattering intensity is predominantly that of the (branched) minority component so that its dynamics is clearly evident. In the present paper, we use the neutron scattering data to validate the branch point withdrawal process, which could not be unambiguously discerned from rheological measurements in this blend. The maximal tube stretch that the inner branches experience, before the relaxed outer arm material is incorporated into the tube is determined. The in situ scattering experiments demonstrate for the first time the leveling-off of the strain as the result of branch point withdrawal and chain retraction directly on the molecular level. We conclude that branch point motion in the mixture of architecturally complex polymers occurs earlier than would be expected in a purely branched system, presumably due to the different topological environment that the linear matrix presents to the hierarchically deep-buried tube sections. © 2016 American Chemical Society.

  16. Primary and scattering contributions to beta scaled dose point kernels by means of Monte Carlo simulations

    International Nuclear Information System (INIS)

    Valente, Mauro; Botta, Francesca; Pedroli, Guido

    2012-01-01

    Beta-emitters have proved to be appropriate for radioimmunotherapy. The dosimetric characterization of each radionuclide has to be carefully investigated. One usual and practical dosimetric approach is the calculation of dose distribution from a unit point source emitting particles according to any radionuclide of interest, which is known as dose point kernel. Absorbed dose distributions are due to primary and radiation scattering contributions. This work presented a method capable of performing dose distributions for nuclear medicine dosimetry by means of Monte Carlo methods. Dedicated subroutines have been developed in order to separately compute primary and scattering contributions to the total absorbed dose, performing particle transport up to 1 keV or least. Preliminarily, the suitability of the calculation method has been satisfactory, being tested for monoenergetic sources, and it was further applied to the characterization of different beta-minus radionuclides of nuclear medicine interests for radioimmunotherapy. (author)

  17. Relationship between the Amplitude and Phase of a Signal Scattered by a Point-Like Acoustic Inhomogeneity

    Science.gov (United States)

    Burov, V. A.; Morozov, S. A.

    2001-11-01

    Wave scattering by a point-like inhomogeneity, i.e., a strong inhomogeneity with infinitesimal dimensions, is described. This type of inhomogeneity model is used in investigating the point-spread functions of different algorithms and systems. Two approaches are used to derive the rigorous relationship between the amplitude and phase of a signal scattered by a point-like acoustic inhomogeneity. The first approach is based on a Marchenko-type equation. The second approach uses the scattering by a scatterer whose size decreases simultaneously with an increase in its contrast. It is shown that the retarded and advanced waves are scattered differently despite the relationship between the phases of the corresponding scattered waves.

  18. Magnetic photon scattering

    International Nuclear Information System (INIS)

    Lovesey, S.W.

    1987-05-01

    The report reviews, at an introductory level, the theory of photon scattering from condensed matter. Magnetic scattering, which arises from first-order relativistic corrections to the Thomson scattering amplitude, is treated in detail and related to the corresponding interaction in the magnetic neutron diffraction amplitude. (author)

  19. A compact multichannel spectrometer for Thomson scatteringa)

    Science.gov (United States)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of Te VPH grating and measurements Te > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (˜2 ns) ICCD camera for detection. A Gen III image intensifier provides ˜45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  20. Semiclassical asymptotics for the scattering amplitude in the presence of focal points at infinity

    Energy Technology Data Exchange (ETDEWEB)

    Hohberger, H.

    2006-10-16

    We consider scattering in R{sup n}, n{>=}2, described by the Schroedinger operator P(h)=-h{sup 2}{delta}+V, where V is a short-range potential. With the aid of Maslov theory, we give a geometrical formula for the semiclassical asymptotics as h{yields}0 of the scattering amplitude f({omega}{sub -},{omega}{sub +};{lambda},h) ({omega}{sub +}{ne}{omega}{sub -}) which remains valid in the presence of focal points at infinity (caustics). Crucial for this analysis are precise estimates on the asymptotics of the classical phase trajectories and the relationship between caustics in euclidean phase space and caustics at infinity. (orig.)

  1. Long-range nonlocality in six-point string scattering: Simulation of black hole infallers

    Science.gov (United States)

    Dodelson, Matthew; Silverstein, Eva

    2017-09-01

    We set up a tree-level six-point scattering process in which two strings are separated longitudinally such that they could only interact directly via a nonlocal spreading effect such as that predicted by light-cone gauge calculations and the Gross-Mende saddle point. One string, the "detector," is produced at a finite time with energy E by an auxiliary 2 →2 subprocess, with kinematics such that it has sufficient resolution to detect the longitudinal spreading of an additional incoming string, the "source." We test this hypothesis in a gauge-invariant S-matrix calculation convolved with an appropriate wavepacket peaked at a separation X between the central trajectories of the source and produced detector. The amplitude exhibits support for scattering at the predicted longitudinal separation X ˜α'E , in sharp contrast to the analogous quantum field theory amplitude (whose support manifestly traces out a tail of the position-space wavefunction). The effect arises in a regime in which the string amplitude is not obtained as a convergent sum of such QFT amplitudes, and has larger amplitude than similar QFT models (with the same auxiliary four-point amplitude). In a linear dilaton background, the amplitude depends on the string coupling as expected if the scattering is not simply occurring on the wavepacket tail in string theory. This manifests the scale of longitudinal spreading in a gauge-invariant S-matrix amplitude, in a calculable process with significant amplitude. It simulates a key feature of the dynamics of time-translated horizon infallers.

  2. Some aspects of transition radiation and scattering theory

    International Nuclear Information System (INIS)

    Ginzburg, V.L.; Tsytovich, V.N.

    1978-01-01

    Some aspects of transition radiation and transition scattering theory are considered. The transition radiation in vacuum is analysed in the presence of a strong magnetic field. It is shown, that the constant electro-magnetic field makes vacuum similar to the uniaxial ferrodielectric. The appearance of the transition radiation in the nonstationary medium is discussed when its properties in the medium change abruptly in time. It is obtained, that both types of the transition radiation for nonrelativistic particles (on an abrupt boundary of the two media interface and under an abrupt change in time of the medium properties) differ quantitatively (on the order of the value). The role of the radiation transition and scattering in plasma physics has been elucidated from different points. Four most important features of these processes are pointed out. Particularly, essential is shown to be the type of the transition scattering when one plasma wave, being the dielectric constant wave transforms into another one also a plasma wave. In the processes of the transition scattering an essential part is played by the effects of the space dispersion, particularly when the scattering takes place on the small velocity particles. Finally besides transition scattering there exists in plasma or in some cases prevails a Thomson scattering. In this case an important role in plasma is played by the interference between the Thomson and the transition scattering

  3. General point dipole theory for periodic metasurfaces: magnetoelectric scattering lattices coupled to planar photonic structures.

    Science.gov (United States)

    Chen, Yuntian; Zhang, Yan; Femius Koenderink, A

    2017-09-04

    We study semi-analytically the light emission and absorption properties of arbitrary stratified photonic structures with embedded two-dimensional magnetoelectric point scattering lattices, as used in recent plasmon-enhanced LEDs and solar cells. By employing dyadic Green's function for the layered structure in combination with the Ewald lattice summation to deal with the particle lattice, we develop an efficient method to study the coupling between planar 2D scattering lattices of plasmonic, or metamaterial point particles, coupled to layered structures. Using the 'array scanning method' we deal with localized sources. Firstly, we apply our method to light emission enhancement of dipole emitters in slab waveguides, mediated by plasmonic lattices. We benchmark the array scanning method against a reciprocity-based approach to find that the calculated radiative rate enhancement in k-space below the light cone shows excellent agreement. Secondly, we apply our method to study absorption-enhancement in thin-film solar cells mediated by periodic Ag nanoparticle arrays. Lastly, we study the emission distribution in k-space of a coupled waveguide-lattice system. In particular, we explore the dark mode excitation on the plasmonic lattice using the so-called array scanning method. Our method could be useful for simulating a broad range of complex nanophotonic structures, i.e., metasurfaces, plasmon-enhanced light emitting systems and photovoltaics.

  4. Precise and efficient evaluation of gravimetric quantities at arbitrarily scattered points in space

    Science.gov (United States)

    Ivanov, Kamen G.; Pavlis, Nikolaos K.; Petrushev, Pencho

    2017-12-01

    Gravimetric quantities are commonly represented in terms of high degree surface or solid spherical harmonics. After EGM2008, such expansions routinely extend to spherical harmonic degree 2190, which makes the computation of gravimetric quantities at a large number of arbitrarily scattered points in space using harmonic synthesis, a very computationally demanding process. We present here the development of an algorithm and its associated software for the efficient and precise evaluation of gravimetric quantities, represented in high degree solid spherical harmonics, at arbitrarily scattered points in the space exterior to the surface of the Earth. The new algorithm is based on representation of the quantities of interest in solid ellipsoidal harmonics and application of the tensor product trigonometric needlets. A FORTRAN implementation of this algorithm has been developed and extensively tested. The capabilities of the code are demonstrated using as examples the disturbing potential T, height anomaly ζ , gravity anomaly Δ g , gravity disturbance δ g , north-south deflection of the vertical ξ , east-west deflection of the vertical η , and the second radial derivative T_{rr} of the disturbing potential. After a pre-computational step that takes between 1 and 2 h per quantity, the current version of the software is capable of computing on a standard PC each of these quantities in the range from the surface of the Earth up to 544 km above that surface at speeds between 20,000 and 40,000 point evaluations per second, depending on the gravimetric quantity being evaluated, while the relative error does not exceed 10^{-6} and the memory (RAM) use is 9.3 GB.

  5. Structures and interactions among globular proteins above the isoelectric point in the presence of divalent ions: A small angle neutron scattering and dynamic light scattering study

    Science.gov (United States)

    Kundu, Sarathi; Pandit, Subhankar; Abbas, Sohrab; Aswal, V. K.; Kohlbrecher, J.

    2018-02-01

    Small angle neutron scattering study reveals that at pD ≈ 7.0, above the isoelectric point of the globular protein Bovine Serum Albumin (BSA), in the presence of different divalent ions (Mg2+, Ca2+, Sr2+ and Ba2+), the short-range attractive interaction remains nearly constant and the intermediate-range repulsive interaction decreases with increasing salt concentration up to a certain concentration value but after that remains unchanged. However, for the monovalent ion (Na+), repulsive interaction decreases gradually up to 1 M salt concentration. Dynamic light scattering study shows that for all ions, diffusion coefficient of BSA decreases with increasing salt concentration and then nearly saturates.

  6. SCATTER

    International Nuclear Information System (INIS)

    Broome, J.

    1965-11-01

    The programme SCATTER is a KDF9 programme in the Egtran dialect of Fortran to generate normalized angular distributions for elastically scattered neutrons from data input as the coefficients of a Legendre polynomial series, or from differential cross-section data. Also, differential cross-section data may be analysed to produce Legendre polynomial coefficients. Output on cards punched in the format of the U.K. A. E. A. Nuclear Data Library is optional. (author)

  7. Special Important Aspects of the Thomson Effect

    Science.gov (United States)

    Lashkevych, Igor; Velázquez, J. E.; Titov, Oleg Yu.; Gurevich, Yuri G.

    2018-03-01

    A comprehensive study of the mechanisms of heating and cooling originating from an electrical current in semiconductor devices is reported. The variation in temperature associated with the Peltier effect is not related to the presence of heat sources and sinks if the heat flux is correctly determined. The Thomson effect is commonly regarded as a heat source/sink proportional to the Thomson coefficient, which is added to the Joule heating. In the present work, we will show that this formulation of the Thomson effect is not sufficiently clear. When the heat flux is correctly defined, the Thomson heat source/sink is proportional to the Seebeck coefficient. In the conditions in which the Peltier effect takes place, the temperature gradient is created, and, consequently, the Thomson effect will occur naturally.

  8. The study of membrane formation via phase inversion method by cloud point and light scattering experiment

    Science.gov (United States)

    Arahman, Nasrul; Maimun, Teuku; Mukramah, Syawaliah

    2017-01-01

    The composition of polymer solution and the methods of membrane preparation determine the solidification process of membrane. The formation of membrane structure prepared via non-solvent induced phase separation (NIPS) method is mostly determined by phase separation process between polymer, solvent, and non-solvent. This paper discusses the phase separation process of polymer solution containing Polyethersulfone (PES), N-methylpirrolidone (NMP), and surfactant Tetronic 1307 (Tet). Cloud point experiment is conducted to determine the amount of non-solvent needed on induced phase separation. Amount of water required as a non-solvent decreases by the addition of surfactant Tet. Kinetics of phase separation for such system is studied by the light scattering measurement. With the addition of Tet., the delayed phase separation is observed and the structure growth rate decreases. Moreover, the morphology of fabricated membrane from those polymer systems is analyzed by scanning electron microscopy (SEM). The images of both systems show the formation of finger-like macrovoids through the cross-section.

  9. The collapsed cone algorithm for (192)Ir dosimetry using phantom-size adaptive multiple-scatter point kernels.

    Science.gov (United States)

    Tedgren, Åsa Carlsson; Plamondon, Mathieu; Beaulieu, Luc

    2015-07-07

    The aim of this work was to investigate how dose distributions calculated with the collapsed cone (CC) algorithm depend on the size of the water phantom used in deriving the point kernel for multiple scatter. A research version of the CC algorithm equipped with a set of selectable point kernels for multiple-scatter dose that had initially been derived in water phantoms of various dimensions was used. The new point kernels were generated using EGSnrc in spherical water phantoms of radii 5 cm, 7.5 cm, 10 cm, 15 cm, 20 cm, 30 cm and 50 cm. Dose distributions derived with CC in water phantoms of different dimensions and in a CT-based clinical breast geometry were compared to Monte Carlo (MC) simulations using the Geant4-based brachytherapy specific MC code Algebra. Agreement with MC within 1% was obtained when the dimensions of the phantom used to derive the multiple-scatter kernel were similar to those of the calculation phantom. Doses are overestimated at phantom edges when kernels are derived in larger phantoms and underestimated when derived in smaller phantoms (by around 2% to 7% depending on distance from source and phantom dimensions). CC agrees well with MC in the high dose region of a breast implant and is superior to TG43 in determining skin doses for all multiple-scatter point kernel sizes. Increased agreement between CC and MC is achieved when the point kernel is comparable to breast dimensions. The investigated approximation in multiple scatter dose depends on the choice of point kernel in relation to phantom size and yields a significant fraction of the total dose only at distances of several centimeters from a source/implant which correspond to volumes of low doses. The current implementation of the CC algorithm utilizes a point kernel derived in a comparatively large (radius 20 cm) water phantom. A fixed point kernel leads to predictable behaviour of the algorithm with the worst case being a source/implant located well within a patient

  10. Thomson parabola ion energy analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Cobble, James A [Los Alamos National Laboratory; Flippo, Kirk A [Los Alamos National Laboratory; Letzring, Samuel A [Los Alamos National Laboratory; Lopez, Frank E [Los Alamos National Laboratory; Offermann, Dustin T [Los Alamos National Laboratory; Oertel, John A [Los Alamos National Laboratory; Mastrosimone, Dino [UNIV OF ROCHESTER

    2010-01-01

    A new, versatile Thomson parabola ion energy (TPIE) analyzer has been designed and constructed for use at the OMEGA-EP facility. Multi-MeV ions from EP targets are transmitted through a W pinhole into a (5- or 8-kG) magnetic field and subsequently through a parallel electric field of up to 30 kV/cm. The ion drift region may have a user-selected length of 10, 50, or 80 cm. With the highest fields, 500-Me V C{sup 6+} and C{sup 5+} may be resolved. TPIE is TIM-mounted at OMEGA-EP and is qualified in all existing TIMs. The instrument runs on pressure-interlocked 15-VDC power available in EP TIM carts. It may be inserted to within several inches of the target to attain sufficient flux for a measurement. For additional flux control, the user may select a square-aperture W pinhole of 0.004-inch or 0.010-inch. The detector consists of CR-39 backed by an image plate. The fully relativistic design code and design features are discussed. Ion spectral results from first use at OMEGA-EP are expected.

  11. An objective scatter index based on double-pass retinal images of a point source to classify cataracts.

    Directory of Open Access Journals (Sweden)

    Pablo Artal

    Full Text Available PURPOSE: To propose a new objective scatter index (OSI based in the analysis of double-pass images of a point source to rank and classify cataract patients. This classification scheme is compared with a current subjective system. METHODS: We selected a population including a group of normal young eyes as control and patients diagnosed with cataract (grades NO2, NO3 and NO4 according to the Lens Opacities Classification System (LOCS III. For each eye, we recorded double-pass retinal images of a point source. In each patient, we determined an objective scatter index (OSI as the ratio of the intensity at an eccentric location in the image and the central part. This index provides information on the relevant forward scatter affecting vision. Since the double-pass retinal images are affected by both ocular aberrations and intraocular scattering, an analysis was performed to show the ranges of contributions of aberrations to the OSI. RESULTS: We used the OSI values to classify each eye according to the degree of scatter. The young normal eyes of the control group had OSI values below 1, while the OSI for subjects in LOCS grade II were around 1 to 2. The use of the objective index showed some of the weakness of subjective classification schemes. In particular, several subjects initially classified independently as grade NO2 or NO3 had similar OSI values, and in some cases even higher than subjects classified as grade NO4. A new classification scheme based in OSI is proposed. CONCLUSIONS: We introduced an objective index based in the analysis of double-pass retinal images to classify cataract patients. The method is robust and fully based in objective measurements; i.e., not depending on subjective decisions. This procedure could be used in combination with standard current methods to improve cataract patient surgery scheduling.

  12. Strains of scattering of near-field of a point source

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    express the coda wave-field in terms of scattering by a primary wavelet interacting with hetero- geneities (Aki and Richards 1980). Typical fluctua- tion of around 5 per cent in crustal velocity (Leary. 1990) favours the first order perturbation approach in solving the elastic wave equation for a hetero- geneous medium.

  13. An Investigation of the High Efficiency Estimation Approach of the Large-Scale Scattered Point Cloud Normal Vector

    Directory of Open Access Journals (Sweden)

    Xianglin Meng

    2018-03-01

    Full Text Available The normal vector estimation of the large-scale scattered point cloud (LSSPC plays an important role in point-based shape editing. However, the normal vector estimation for LSSPC cannot meet the great challenge of the sharp increase of the point cloud that is mainly attributed to its low computational efficiency. In this paper, a novel, fast method-based on bi-linear interpolation is reported on the normal vector estimation for LSSPC. We divide the point sets into many small cubes to speed up the local point search and construct interpolation nodes on the isosurface expressed by the point cloud. On the premise of calculating the normal vectors of these interpolated nodes, a normal vector bi-linear interpolation of the points in the cube is realized. The proposed approach has the merits of accurate, simple, and high efficiency, because the algorithm only needs to search neighbor and calculates normal vectors for interpolation nodes that are usually far less than the point cloud. The experimental results of several real and simulated point sets show that our method is over three times faster than the Elliptic Gabriel Graph-based method, and the average deviation is less than 0.01 mm.

  14. A diode laser-based velocimeter providing point measurements in unseeded flows using modulated filtered Rayleigh scattering (MFRS)

    Science.gov (United States)

    Jagodzinski, Jeremy James

    2007-12-01

    The development to date of a diode-laser based velocimeter providing point-velocity-measurements in unseeded flows using molecular Rayleigh scattering is discussed. The velocimeter is based on modulated filtered Rayleigh scattering (MFRS), a novel variation of filtered Rayleigh scattering (FRS), utilizing modulated absorption spectroscopy techniques to detect a strong absorption of a relatively weak Rayleigh scattered signal. A rubidium (Rb) vapor filter is used to provide the relatively strong absorption; alkali metal vapors have a high optical depth at modest vapor pressures, and their narrow linewidth is ideally suited for high-resolution velocimetry. Semiconductor diode lasers are used to generate the relatively weak Rayleigh scattered signal; due to their compact, rugged construction diode lasers are ideally suited for the environmental extremes encountered in many experiments. The MFRS technique utilizes the frequency-tuning capability of diode lasers to implement a homodyne detection scheme using lock-in amplifiers. The optical frequency of the diode-based laser system used to interrogate the flow is rapidly modulated about a reference frequency in the D2-line of Rb. The frequency modulation is imposed on the Rayleigh scattered light that is collected from the probe volume in the flow under investigation. The collected frequency modulating Rayleigh scattered light is transmitted through a Rb vapor filter before being detected. The detected modulated absorption signal is fed to two lock-in amplifers synchronized with the modulation frequency of the source laser. High levels of background rejection are attained since the lock-ins are both frequency and phase selective. The two lock-in amplifiers extract different Fourier components of the detected modulated absorption signal, which are ratioed to provide an intensity normalized frequency dependent signal from a single detector. A Doppler frequency shift in the collected Rayleigh scattered light due to a change

  15. JJ Thomson-A'Thinking'Experimentalist

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 12. J. J. Thomson - A 'Thinking' Experimentalist. Rohini M Godbole. Article-in-a-Box Volume 2 Issue 12 December 1997 pp 2-4. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/12/0002-0004 ...

  16. JJ Thomson-A'Thinking'Experimentalist

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 10; Issue 12. J. J. Thomson - A 'Thinking' Experimentalist. Rohini Godbole. Volume 10 Issue 12 December 2005 pp 55-57. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/010/12/0055-0057 ...

  17. Investigating Spatial Patterns of Persistent Scatterer Interferometry Point Targets and Landslide Occurrences in the Arno River Basin

    Directory of Open Access Journals (Sweden)

    Ping Lu

    2014-07-01

    Full Text Available Persistent Scatterer Interferometry (PSI has been widely used for landslide studies in recent years. This paper investigated the spatial patterns of PSI point targets and landslide occurrences in the Arno River basin in Central Italy. The main purpose is to analyze whether spatial patterns of Persistent Scatterers (PS can be recognized as indicators of landslide occurrences throughout the whole basin. The bivariate K-function was employed to assess spatial relationships between PS and landslides. The PSI point targets were acquired from almost 4 years (from March 2003 to January 2007 of RADARSAT-1 images. The landslide inventory was collected from 15 years (from 1992–2007 of surveying and mapping data, mainly including remote sensing data, topographic maps and field investigations. The proposed approach is able to assess spatial patterns between a variety of PS and landslides, in particular, to understand if PSI point targets are spatially clustered (spatial attraction or randomly distributed (spatial independency on various types of landslides across the basin. Additionally, the degree and scale distances of PS clustering on a variety of landslides can be characterized. The results rejected the null hypothesis that PSI point targets appear to cluster similarly on four types of landslides (slides, flows, falls and creeps in the Arno River basin. Significant influence of PS velocities and acquisition orbits can be noticed on detecting landslides with different states of activities. Despite that the assessment may be influenced by the quality of landslide inventory and Synthetic Aperture Radar (SAR images, the proposed approach is expected to provide guidelines for studies trying to detect and investigate landslide occurrences at a regional scale through spatial statistical analysis of PS, for which an advanced understanding of the impact of scale distances on landslide clustering is fundamentally needed.

  18. Radar Image Simulation: Validation of the Point Scattering Method. Volume 2

    Science.gov (United States)

    1977-09-01

    the Engineer Topographic Labor - atory (ETL), Fort Belvoir, Virginia. This Radar Simulation Study was performed to validate the point tcattering radar...e.n For radar, the number of Independent samples in a given re.-olution cell is given by 5 ,: N L 2w (16) L Acoso where: 0 Radar incidence angle; w

  19. 3D registration method based on scattered point cloud from B-model ultrasound image

    Science.gov (United States)

    Hu, Lei; Xu, Xiaojun; Wang, Lifeng; Guo, Na; Xie, Feng

    2017-01-01

    The paper proposes a registration method on 3D point cloud of the bone tissue surface extracted by B-mode ultrasound image and the CT model . The B-mode ultrasound is used to get two-dimensional images of the femur tissue . The binocular stereo vision tracker is used to obtain spatial position and orientation of the optical positioning device fixed on the ultrasound probe. The combining of the two kind of data generates 3D point cloud of the bone tissue surface. The pixel coordinates of the bone surface are automatically obtained from ultrasound image using an improved local phase symmetry (phase symmetry, PS) . The mapping of the pixel coordinates on the ultrasound image and 3D space is obtained through a series of calibration methods. In order to detect the effect of registration, six markers are implanted on a complete fresh pig femoral .The actual coordinates of the marks are measured with two methods. The first method is to get the coordinates with measuring tools under a coordinate system. The second is to measure the coordinates of the markers in the CT model registered with 3D point cloud using the ICP registration algorithm under the same coordinate system. Ten registration experiments are carried out in the same way. Error results are obtained by comparing the two sets of mark point coordinates obtained by two different methods. The results is that a minimum error is 1.34mm, the maximum error is 3.22mm,and the average error of 2.52mm; ICP registration algorithm calculates the average error of 0.89mm and a standard deviation of 0.62mm.This evaluation standards of registration accuracy is different from the average error obtained by the ICP registration algorithm. It can be intuitive to show the error caused by the operation of clinical doctors. Reference to the accuracy requirements of different operation in the Department of orthopedics, the method can be apply to the bone reduction and the anterior cruciate ligament surgery.

  20. Review and calculation of Mott scattering cross section by unscreened point nuclei

    International Nuclear Information System (INIS)

    Idoeta, R.; Legarda, F.

    1992-01-01

    A new tabulation of the ratio of the ''exact'' Mott cross section for unscreened point nuclei to the classical Rutherford cross section for electrons and positions has been made. Because of the infinite slowly converging series appearing in this ratio we have made two series transformations. With this evaluation the ratio reached convergence within six significant figures after less than a hundred terms and very low computing time. So the ratios evaluated have less relative error than those in the literature and covers a greater range of energy and atomic number. (orig.)

  1. Progresses in development of the ITER edge Thomson scattering system

    Czech Academy of Sciences Publication Activity Database

    Yatsuka, E.; Bassan, M.; Hatae, T.; Ishikawa, M.; Shimada, T.; Vayakis, G.; Walsh, M.; Scannell, R.; Huxford, R.; Bílková, Petra; Böhm, Petr; Aftanas, Milan; Itami, K.

    2013-01-01

    Roč. 8, č. 12 (2013), C12001-C12001 ISSN 1748-0221. [International Conference on Laser Aided Plasma Diagnostics (16thLAPD)/16./. Madison, 22.09.2013-26.09.2013] Institutional support: RVO:61389021 Keywords : Data processing methods * Plasma diagnostics - iterferometry * spectroscopy and imaging Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.526, year: 2013 http://iopscience.iop.org/1748-0221/8/12/C12001

  2. The NSTX-U Thomson scattering diagnostic system

    Science.gov (United States)

    Leblanc, B. P.; Diallo, A.; Feder, H.; Labik, G.; Stevens, D. R.; Upcavage, R.

    2012-10-01

    The NSTX-U upgrade consists primarily of two elements: (1) a new Center Stack (CS) of larger diameter, doubling of the toroidal field (MPTS) diagnostic: (1) In order to avoid ablating the CS tile material, the laser beam path has been re-aimed to a larger tangency radius; (2) Since a straight unobstructed laser-beam escape route is precluded by the presence of the new NBI box, a multi-mirror arrangement is being designed. Since it is unpractical to relocate the mirror collection optics to a different machine port, the new laser beam path has been kept as close as possible to the original route. Ray-tracing calculations complemented with in-situ test of principle verification have shown that the original collection optics can reconfigured to image the new laser beam path with acceptable resolution. The NSTX-U MPTS system will benefit from a recent upgrade to 42 radial channels and will continue using two 30-Hz Nd:YAG lasers, although the laser input and exit flight tubes will be given a larger bore in order to permit a straightforward addition of a third laser beam. Progress report will be given of this continuing work.

  3. 105 GHz Notch Filter Design for Collective Thomson Scattering

    DEFF Research Database (Denmark)

    Furtula, Vedran; Michelsen, Poul; Leipold, Frank

    2011-01-01

    A millimeter-wave notch filter with 105-GHz center frequency, >20-GHz passband coverage, and 1-GHz rejection bandwidth has been constructed. The design is based on a fundamental rectangular waveguide with cylindrical cavities coupled by narrow iris gaps, i.e., small elongated holes of negligible...... thickness. We use numerical simulations to study the sensitivity of the notch filter performance to changes in geometry and in material conductivity within a bandwidth of ±10 GHz. The constructed filter is tested successfully using a vector network analyzer monitoring a total bandwidth of 20 GHz....... The typical insertion loss in the passband is...

  4. Fast Ion Collective Thomson Scattering Diagnostic for ITER

    DEFF Research Database (Denmark)

    Korsholm, Søren Bang; Bindslev, Henrik; Furtula, Vedran

    2008-01-01

    In the era of high power and burning plasma fusion experiments with significant populations of fast particles, the diagnosis of fast ion dynamics becomes an important topic. In ITER, populations of fast ions due to ICRH and NBI, as well as fusion born alphas will carry a significant fraction of t...... of mock-up measurements have brought the design towards a four mirror quasi-optical solution. The development as well as the present design will be presented....

  5. Example of two distinct potentials without point eigenvalues which have the same scattering operator with the reflection coefficient c(0) = -1

    International Nuclear Information System (INIS)

    Moses, H.E.

    1983-01-01

    Abraham, DeFacio, and Moses and Brownstein have given examples of pairs of potentials, which support no point eigenvalues, but which have the same scattering operator. These potentials all have delta-function contributions to them. In the present paper, a pair of potentials is given, neither of which has a delta-function contribution, such that they both have the same simple scattering operator. Like the earlier examples, the new potentials violate the range condition of Faddeev and Deift and Trubowitz used in the proof of the one-to-one correspondence of potentials to scattering operators. Thus the present example is an addition to the list of long-range potentials with simple eigenfunctions and scattering operators

  6. Measurement of the Four-Point Susceptibility of an Out-of-Equilibrium Colloidal Solution of Nanoparticles Using Time-Resolved Light Scattering

    DEFF Research Database (Denmark)

    Maggi, Claudio; Di Leonardo, Ricardo; ruocco, giancarlo

    2012-01-01

    The spatial fluctuations of the dynamics of a colloidal system composed of nanoparticles are probed by a novel experimental setup, which combines homodyne and heterodyne dynamic light scattering focused onto a micron-sized volume via a microscope objective. The technique is used to measure the four-point...

  7. Dynamic effects on cyclotron scattering in pulsar accretion columns

    International Nuclear Information System (INIS)

    Brainerd, J.J.; Meszaros, P.

    1991-01-01

    A resonant scattering model for photon reprocessing in a pulsar accretion column is presented. The accretion column is optically thin to Thomson scattering and optically thick to resonant scattering at the cyclotron frequency. Radiation from the neutron star surface propagates freely through the column until the photon energy equals the local cyclotron frequency, at which point the radiation is scattered, much of it back toward the star. The radiation pressure in this regime is insufficient to stop the infall. Some of the scattered radiation heats the stellar surface around the base of the column, which adds a softer component to the spectrum. The partial blocking by the accretion column of X-rays from the surface produces a fan beam emission pattern. X-rays above the surface cyclotron frequency freely escape and are characterized by a pencil beam. Gravitational light bending produces a pencil beam pattern of column-scattered radiation in the antipodal direction, resulting in a strongly angle-dependent cyclotron feature. 31 refs

  8. Quantum Joule-Thomson Effect in a Saturated Homogeneous Bose Gas

    Science.gov (United States)

    Schmidutz, Tobias F.; Gotlibovych, Igor; Gaunt, Alexander L.; Smith, Robert P.; Navon, Nir; Hadzibabic, Zoran

    2014-01-01

    We study the thermodynamics of Bose-Einstein condensation in a weakly interacting quasihomogeneous atomic gas, prepared in an optical-box trap. We characterize the critical point for condensation and observe saturation of the thermal component in a partially condensed cloud, in agreement with Einstein's textbook picture of a purely statistical phase transition. Finally, we observe the quantum Joule-Thomson effect, namely isoenthalpic cooling of an (essentially) ideal gas. In our experiments this cooling occurs spontaneously, due to energy-independent collisions with the background gas in the vacuum chamber. We extract a Joule-Thomson coefficient μJT>109 K /bar, about 10 orders of magnitude larger than observed in classical gases.

  9. Narrow bandwidth Laser-Plasma Accelerator driven Thomson photon source development

    Science.gov (United States)

    Geddes, C. G. R.; Tsai, H.-E.; Otero, G.; Liu, X.; van Tilborg, J.; Toth, Cs.; Vay, J.-L.; Lehe, R.; Schroeder, C. B.; Esarey, E.; Friedman, A.; Grote, D. P.; Leemans, W. P.

    2017-10-01

    Compact, high-quality photon sources at MeV energies can be provided by Thomson scattering of a laser from the electron beam of a Laser-Plasma Accelerator (LPA). Recent experiments and simulations demonstrate controllable LPAs in the energy range appropriate to MeV sources. Simulations indicate that high flux with narrow energy spread can be achieved via control of the scattering laser pulse shape and laser guiding, and that undesired background bremsstrahlung can be mitigated by plasma based deceleration of the electron beam after photon production. Construction of experiments and laser capabilities to combine these elements will be presented, along with initial operations, towards a compact photon source system. Work supported by US DOE NNSA DNN R&D and by Sc. HEP under contract DE-AC02-05CH11231.

  10. Critical neutron scattering in a polymer blend above and below the critical point of demixing: Critical exponents and amplitude ratios

    DEFF Research Database (Denmark)

    Schwahn, D.; Mortensen, K.; Janssen, S.

    1994-01-01

    The critical behavior of a polymer blend was measured by small-angle neutron scattering above and below the critical temperature T-c, i.e., outside and inside the unstable region. The critical exponents and the amplitudes of the susceptibility and the correlation length were determined. For T > T...

  11. Point defect dynamics in sodium aluminum hydrides - a combined quasielastic neutron scattering and density functional theory study

    DEFF Research Database (Denmark)

    Shi, Qing; Voss, Johannes; Jacobsen, H.S.

    2007-01-01

    we study hydrogen dynamics in undoped and TiCl3-doped samples of NaAlH4 and Na3AlH6 using a combination of density functional theory calculations and quasielastic neutron scattering. Hydrogen dynamics is found to be limited and mediated by hydrogen vacancies in both alanate phases, requiring...

  12. Fiber free plug and play on-chip scattering cytometer module – for implementation in microfluidic point of care devices

    DEFF Research Database (Denmark)

    Jensen, Thomas Glasdam; Kutter, Jörg Peter

    2010-01-01

    In this paper, we report on recent progress toward the development of a plug and play on-chip cytometer based on light scattering. By developing a device that does not depend on the critical alignment and cumbersome handling of fragile optical fibers, we approach a device that is suitable for non...

  13. Nanoimprint lithography-based plasmonic crystal-surface enhanced Raman scattering substrate for point of care testing application

    Science.gov (United States)

    Endo, Tatsuro; Yamada, Kenji

    2017-02-01

    Surface enhanced raman scattering (SERS) is known for its high sensitivity toward detection down to single molecule level under optimal conditions using surface plasmon resonance (SPR). To excite the SPR for SERS application, nanostructured noble metal supports such as a nanoparticle have been widely used. However, for excitation of SPR for SERS application using noble metal nanoparticle has several disadvantages such as sophisticated fabrication procedure and low reproducibility of SPR excitation efficiency. To overcome these disadvantages, in this study, plasmonic crystal (PC)-SERS substrate which has a periodic noble metal nanostructure was successfully fabricated rapidly and cost-effectively based on nanoimprint lithography (NIL).

  14. Determination of point isotropic buildup factors of gamma rays including incoherent and coherent scattering for aluminum, iron, lead, and water by discrete ordinates method

    International Nuclear Information System (INIS)

    Kitsos, S.; Assad, A.; Diop, C.M.; Nimal, J.C.

    1994-01-01

    Exposure and energy absorption buildup factors for aluminum, iron, lead, and water are calculated by the SNID discrete ordinates code for an isotropic point source in a homogeneous medium. The calculation of the buildup factors takes into account the effects of both bound-electron Compton (incoherent) and coherent (Rayleigh) scattering. A comparison with buildup factors from the literature shows that these two effects greatly increase the buildup factors for energies below a few hundred kilo-electron-volts, and thus the new results are improved relative to the experiment. This greater accuracy is due to the increase in the linear attenuation coefficient, which leads to the calculation of the buildup factors for a mean free path with a smaller shield thickness. On the other hand, for the same shield thickness, exposure increases when only incoherent scattering is included and decreases when only coherent scattering is included, so that the exposure finally decreases when both effects are included. Great care must also be taken when checking the approximations for gamma-ray deep-penetration transport calculations, as well as for the cross-section treatment and origin

  15. A variational proof of Thomson's theorem

    Energy Technology Data Exchange (ETDEWEB)

    Fiolhais, Miguel C.N., E-mail: miguel.fiolhais@cern.ch [Department of Physics, City College of the City University of New York, 160 Convent Avenue, New York, NY 10031 (United States); Department of Physics, New York City College of Technology, 300 Jay Street, Brooklyn, NY 11201 (United States); LIP, Department of Physics, University of Coimbra, 3004-516 Coimbra (Portugal); Essén, Hanno [Department of Mechanics, Royal Institute of Technology (KTH), Stockholm SE-10044 (Sweden); Gouveia, Tomé M. [Cavendish Laboratory, 19 JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom)

    2016-08-12

    Thomson's theorem of electrostatics, which states the electric charge on a set of conductors distributes itself on the conductor surfaces to minimize the electrostatic energy, is reviewed in this letter. The proof of Thomson's theorem, based on a variational principle, is derived for a set of normal charged conductors, with and without the presence of external electric fields produced by fixed charge distributions. In this novel approach, the variations are performed on both the charge densities and electric potentials, by means of a local Lagrange multiplier associated with Poisson's equation, constraining the two variables.

  16. Improved thermoelectric cooling based on the Thomson effect

    Science.gov (United States)

    Snyder, G. Jeffrey; Khanna, Raghav; Toberer, Eric S.; Heinz, Nicholas A.; Seifert, Wolfgang

    2016-05-01

    Traditional thermoelectric cooling relies on the Peltier effect which produces a temperature drop limited by the figure of merit, zT. This cooling limit is not required from classical thermodynamics but can be traced to problems of thermoelectric compatibility. Alternatively, if a thermoelectric cooler can be designed to achieve full thermoelectric compatibility, lower temperature can be achieved even if the zT is low. In such a device the Thomson effect plays an important role. We present the theoretical concept of a "Thomson cooler," for cryogenic cooling which is designed to maintain thermoelectric compatibility and we derive the requirements for the Seebeck coefficient.

  17. 78 FR 8587 - Thomson Reuters, Finance Operations & Technology Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-02-06

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,755] Thomson Reuters, Finance... of Thomson Reuters, Finance Operations & Technology Division, including on-site leased workers from... administrative services. New findings show that workers of Thomson Reuters, Finance Operations & Technology...

  18. Lasers As Particle Accelerators In Medicine: From Laser-Driven Protons To Imaging With Thomson Sources

    Science.gov (United States)

    Pogorelsky, I. V.; Babzien, M.; Polyanskiy, M. N.; Yakimenko, V.; Dover, N. P.; Palmer, C. A. J.; Najmudin, Z.; Shkolnikov, P.; Williams, O.; Rosenzweig, J.; Oliva, P.; Carpinelli, M.; Golosio, B.; Delogu, P.; Stefanini, A.; Endrizzi, M.

    2011-06-01

    We report our recent progress using a high-power, picosecond CO2 laser for Thomson scattering and ion acceleration experiments. These experiments capitalize on certain advantages of long-wavelength CO2 lasers, such as their high number of photons per energy unit and beneficial wavelength- scaling of the electrons' ponderomotive energy and critical plasma frequency. High X-ray fluxes produced in the interactions of the counter-propagating laser- and electron-beams for obtaining single-shot, high-contrast images of biological objects. The laser, focused on a hydrogen jet, generated a monoenergetic proton beam via the radiation-pressure mechanism. The energy of protons produced by this method scales linearly with the laser's intensity. We present a plan for scaling the process into the range of 100-MeV proton energy via upgrading the CO2 laser. This development will enable an advance to the laser-driven proton cancer therapy.

  19. Revision of the genus Microterys Thomson (Hymenoptera: Encyrtidae) of China

    NARCIS (Netherlands)

    Xu, Z.

    2002-01-01

    The species of Microterys Thomson from China are revised. Forty-three species are described and illustrated, of which 17 are new to science. Seventeen new species are described and illustrated, 26 species of the genus are revised and redescribed. The hosts of 33 species of the genus Microterys are

  20. Joule-Thomson microcooling developments at University of Twente

    NARCIS (Netherlands)

    Cao, H. S.; Vanapalli, S.; Holland, H. J.; Vermeer, C. H.; Ter Brake, H. J.M.; Lerou, P. P.P.M.; Tirolien, T.

    2017-01-01

    The development of Joule-Thomson microcoolers has been an on-going and successful research project at the University of Twente for many years. The aim of the research is to develop small and fully integrated cryogenic cooling systems for cooling small electronic devices such as pre-amplifiers and

  1. Characterization of a thermoelectric/Joule–Thomson hybrid microcooler

    NARCIS (Netherlands)

    Cao, Haishan; Vanapalli, Srinivas; Holland, Herman J.; Vermeer, Cristian Hendrik; ter Brake, Hermanus J.M.

    2016-01-01

    Micromachined Joule–Thomson (JT) coolers are attractive for cooling small electronic devices. However, microcoolers operated with pure gases, such as nitrogen gas require high pressures of about 9 MPa to achieve reasonable cooling powers. Such high pressures severely add complexity to the

  2. Isotopic imaging via nuclear resonance fluorescence with laser-based Thomson radiation

    Science.gov (United States)

    Barty, Christopher P. J. [Hayward, CA; Hartemann, Frederic V [San Ramon, CA; McNabb, Dennis P [Alameda, CA; Pruet, Jason A [Brentwood, CA

    2009-07-21

    The present invention utilizes novel laser-based, high-brightness, high-spatial-resolution, pencil-beam sources of spectrally pure hard x-ray and gamma-ray radiation to induce resonant scattering in specific nuclei, i.e., nuclear resonance fluorescence. By monitoring such fluorescence as a function of beam position, it is possible to image in either two dimensions or three dimensions, the position and concentration of individual isotopes in a specific material configuration. Such methods of the present invention material identification, spatial resolution of material location and ability to locate and identify materials shielded by other materials, such as, for example, behind a lead wall. The foundation of the present invention is the generation of quasimonochromatic high-energy x-ray (100's of keV) and gamma-ray (greater than about 1 MeV) radiation via the collision of intense laser pulses from relativistic electrons. Such a process as utilized herein, i.e., Thomson scattering or inverse-Compton scattering, produces beams having diameters from about 1 micron to about 100 microns of high-energy photons with a bandwidth of .DELTA.E/E of approximately 10E.sup.-3.

  3. Determination of gold nanoparticles in environmental water samples by second-order optical scattering using dithiotreitol-functionalized CdS quantum dots after cloud point extraction

    International Nuclear Information System (INIS)

    Mandyla, Spyridoula P.; Tsogas, George Z.; Vlessidis, Athanasios G.; Giokas, Dimosthenis L.

    2017-01-01

    Highlights: • A new method has been developed to determine gold nanoparticles in water samples. • Extraction was achieved by cloud point extraction. • A nano-hybrid assembly between AuNPs and dithiol-coated quantum dots was formulated. • Detection was accomplished at pico-molar levels by second-order light scattering. • The method was selective against ionic gold and other nanoparticle species. - Abstract: This work presents a new method for the sensitive and selective determination of gold nanoparticles in water samples. The method combines a sample preparation and enrichment step based on cloud point extraction with a new detection motif that relies on the optical incoherent light scattering of a nano-hybrid assembly that is formed by hydrogen bond interactions between gold nanoparticles and dithiotreitol-functionalized CdS quantum dots. The experimental parameters affecting the extraction and detection of gold nanoparticles were optimized and evaluated to the analysis of gold nanoparticles of variable size and surface coating. The selectivity of the method against gold ions and other nanoparticle species was also evaluated under different conditions reminiscent to those usually found in natural water samples. The developed method was applied to the analysis of gold nanoparticles in natural waters and wastewater with satisfactory results in terms of sensitivity (detection limit at the low pmol L −1 levels), recoveries (>80%) and reproducibility (<9%). Compared to other methods employing molecular spectrometry for metal nanoparticle analysis, the developed method offers improved sensitivity and it is easy-to-operate thus providing an additional tool for the monitoring and the assessment of nanoparticles toxicity and hazards in the environment.

  4. Determination of gold nanoparticles in environmental water samples by second-order optical scattering using dithiotreitol-functionalized CdS quantum dots after cloud point extraction

    Energy Technology Data Exchange (ETDEWEB)

    Mandyla, Spyridoula P.; Tsogas, George Z.; Vlessidis, Athanasios G.; Giokas, Dimosthenis L., E-mail: dgiokas@cc.uoi.gr

    2017-02-05

    Highlights: • A new method has been developed to determine gold nanoparticles in water samples. • Extraction was achieved by cloud point extraction. • A nano-hybrid assembly between AuNPs and dithiol-coated quantum dots was formulated. • Detection was accomplished at pico-molar levels by second-order light scattering. • The method was selective against ionic gold and other nanoparticle species. - Abstract: This work presents a new method for the sensitive and selective determination of gold nanoparticles in water samples. The method combines a sample preparation and enrichment step based on cloud point extraction with a new detection motif that relies on the optical incoherent light scattering of a nano-hybrid assembly that is formed by hydrogen bond interactions between gold nanoparticles and dithiotreitol-functionalized CdS quantum dots. The experimental parameters affecting the extraction and detection of gold nanoparticles were optimized and evaluated to the analysis of gold nanoparticles of variable size and surface coating. The selectivity of the method against gold ions and other nanoparticle species was also evaluated under different conditions reminiscent to those usually found in natural water samples. The developed method was applied to the analysis of gold nanoparticles in natural waters and wastewater with satisfactory results in terms of sensitivity (detection limit at the low pmol L{sup −1} levels), recoveries (>80%) and reproducibility (<9%). Compared to other methods employing molecular spectrometry for metal nanoparticle analysis, the developed method offers improved sensitivity and it is easy-to-operate thus providing an additional tool for the monitoring and the assessment of nanoparticles toxicity and hazards in the environment.

  5. The Gibbs equation versus the Kelvin and the Gibbs-Thomson equations to describe nucleation and equilibrium of nano-materials.

    Science.gov (United States)

    Kaptay, George

    2012-03-01

    The Kelvin equation, the Gibbs equation and the Gibbs-Thomson equation are compared. It is shown that the Kelvin equation (on equilibrium vapor pressure above nano-droplets) can be derived if the inner pressure due to the curvature (from the Laplace equation) is substituted incorrectly into the external pressure term of the Gibbs equation. Thus, the Kelvin equation is excluded in its present form. The Gibbs-Thomson equation (on so-called equilibrium melting point of a nano-crystal) is an analog of the Kelvin equation, and thus it is also excluded in its present form. The contradiction between the critical nucleus size (from the Gibbs equation) and the so-called equilibrium melting point of nano-crystals (from the Gibbs-Thomson equation) is explained. The contradiction is resolved if the Gibbs equation is applied to study both nucleation and equilibrium of nano-crystals. Thus, the difference in the behavior of nano-systems compared to macro-systems is due to their high specific surface area (Gibbs) and not to the high curvature of their interface (Kelvin). Modified versions of the Kelvin equation and the Gibbs-Thomson equation are derived from the Gibbs equation for phases with a general shape and for a spherical phase.

  6. Thomson parabola spectrometry for gold laser generated plasmas

    Czech Academy of Sciences Publication Activity Database

    Torrisi, L.; Cutroneo, M.; Andó, L.; Ullschmied, Jiří

    2013-01-01

    Roč. 20, č. 2 (2013), 023106-023106 ISSN 1070-664X R&D Projects: GA MŠk LM2010014 Institutional research plan: CEZ:AV0Z20430508 Keywords : acceleration * ions * Thomson parabola spectrometry * PALS laser * laser targets * gold ions Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.249, year: 2013 http://pop.aip.org/resource/1/phpaen/v20/i2/p023106_s1

  7. Rothmund-Thomson syndrome and tolerance of chemoradiotherapy

    International Nuclear Information System (INIS)

    Borg, M.F.; Olver, I.N.; Hill, M.P.

    1998-01-01

    Rothmund-Thomson syndrome (RTS) is a rare disorder with a predisposition for cutaneous and non-cutaneous malignancy. It is speculated that ultraviolet (UV) sensitivity and deficient DNA repair may account for this predisposition and influence the tolerance of chemoradiotherapeutic management. A case is reported of the management of an RTS patient with squamous cell carcinoma of the tongue who demonstrated increased radiosensitivity and tissue intolerance to chemotherapy. Copyright (1998) Blackwell Science Pty Ltd

  8. Four new species of Nyctonympha Thomson, 1868 (Coleoptera, Cerambycidae, Lamiinae

    Directory of Open Access Journals (Sweden)

    Antonio Santos-Silva

    2017-06-01

    Full Text Available Four new species of Nyctonympha Thomson, 1868 are described: N. antonkozlovi sp. nov. and N. sinjaevi sp. nov. from Colombia, N. birai sp. nov. from Venezuela and N. mariahelenae sp. nov. from Brazil (Rondônia, Bolivia and Peru. Nyctonympha flavipes Aurivillius, 1990 is formally excluded from the Peruvian and Brazilian fauna. A provisional key to species of Nyctonympha is provided.

  9. Determination of gold nanoparticles in environmental water samples by second-order optical scattering using dithiotreitol-functionalized CdS quantum dots after cloud point extraction.

    Science.gov (United States)

    Mandyla, Spyridoula P; Tsogas, George Z; Vlessidis, Athanasios G; Giokas, Dimosthenis L

    2017-02-05

    This work presents a new method for the sensitive and selective determination of gold nanoparticles in water samples. The method combines a sample preparation and enrichment step based on cloud point extraction with a new detection motif that relies on the optical incoherent light scattering of a nano-hybrid assembly that is formed by hydrogen bond interactions between gold nanoparticles and dithiotreitol-functionalized CdS quantum dots. The experimental parameters affecting the extraction and detection of gold nanoparticles were optimized and evaluated to the analysis of gold nanoparticles of variable size and surface coating. The selectivity of the method against gold ions and other nanoparticle species was also evaluated under different conditions reminiscent to those usually found in natural water samples. The developed method was applied to the analysis of gold nanoparticles in natural waters and wastewater with satisfactory results in terms of sensitivity (detection limit at the low pmolL -1 levels), recoveries (>80%) and reproducibility (metal nanoparticle analysis, the developed method offers improved sensitivity and it is easy-to-operate thus providing an additional tool for the monitoring and the assessment of nanoparticles toxicity and hazards in the environment. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Photon scattering by the giant dipole resonance

    International Nuclear Information System (INIS)

    Bowles, T.J.; Holt, R.J.; Jackson, H.E.; McKeown, R.D.; Specht, J.R.

    1979-01-01

    Although many features of the giant dipole resonance are well known, the coupling between the basic dipole oscillation and other nuclear collective degrees of freedom such as surface vibrations and rotations is poorly understood. This aspect was investigated by elastic and inelastic bremsstrahlung scattering of tagged photons over the energy range 15 to 22 MeV. Target nuclei were 60 Ni, 52 Cr, 56 Fe, 92 Mo, and 96 Mo. Scattering and absorption cross sections are tabulated, along with parameters obtained from a two-Lorentzian analysis of the scattering cross sections; measured spectra are shown. It was necessary to remove Thomson scattering from the experimental results. It was found that coupling to surface vibrations in the giant dipole resonance is much weaker than the dynamic collective model suggests. The elastic scattering cross section for all targets but 60 Ni showed structure that is not evident in the absorption cross section measurement. 12 figures, 2 tables

  11. The Kelvin-Thomson Atom. Part 2: The Many-Electron Atoms

    Science.gov (United States)

    Walton, Alan J.

    1977-01-01

    Presents part two of a two-part article describing the Kelvin-Thomson atom. This part discusses the arrangement of electrons within the atom and examines some of the properties predicted for elements in the Kelvin-Thomson model. (SL)

  12. The role of R. B. Thomson brief heralds of the science in South ...

    African Journals Online (AJOL)

    1990-09-15

    Sep 15, 1990 ... The second, Stibbe, fulfilled a similar role at the South. African School of Mines and Technology, ... in recognition of their historical roles, the Thomson-Stibbe. Lecture. The order of the two names in the ... Both Thomson and Stibbe are examples of those remarkable sons of Scotia's soil - as Professor Maxie ...

  13. Multiple Low Energy Long Bone Fractures in the Setting of Rothmund-Thomson Syndrome

    Directory of Open Access Journals (Sweden)

    Nicholas Beckmann

    2015-01-01

    Full Text Available Rothmund-Thomson syndrome is a rare autosomal recessive genodermatosis characterized by a poikilodermatous rash starting in infancy as well as various skeletal anomalies, juvenile cataracts, and predisposition to certain cancers. Although Rothmund-Thomson syndrome is associated with diminished bone mineral density in addition to multiple skeletal abnormalities, there are few reports of the association with stress fractures or pathologic fractures in low energy trauma or delayed healing of fractures. Presented is a case of a young adult male with Rothmund-Thomson syndrome presenting with multiple episodes of long bone fractures caused by low energy trauma with one of the fractures exhibiting significantly delayed healing. The patient was also found to have an asymptomatic stress fracture of the lower extremity, another finding of Rothmund-Thomson syndrome rarely reported in the literature. A thorough review of the literature and comprehensive presentation of Rothmund-Thomson syndrome is provided in conjunction with our case.

  14. Miniature Joule-Thomson cryocooling principles and practice

    CERN Document Server

    Maytal, Ben-Zion

    2013-01-01

    This book is the first in English being entirely dedicated to Miniature Joule-Thomson Cryocooling. The category of Joule-Thomson (JT) cryocoolers takes us back to the roots of cryogenics, in 1895, with figures like Linde and Hampson. The "cold finger" of these cryocoolers is compact, lacks moving parts, and sustains a large heat flux extraction at a steady temperature. Potentially, they cool down unbeatably fast. For example, cooling to below 100 K (minus 173 Celsius) might be accomplished within only a few seconds by liquefying argon. A level of about 120 K can be reached almost instantly with krypton. Indeed, the species of coolant plays a central role dictating the size, the intensity and the level of cryocooling. It is the JT effect that drives these cryocoolers and reflects the deviation of the "real" gas from the ideal gas properties. The nine chapters of the book are arranged in five parts. • The Common Principle of Cyrocoolers shared across the broad variety of cryocooler types • Theoretical Aspec...

  15. Theoretical considerations for X-ray phase contrast mammography by Thomson source

    Energy Technology Data Exchange (ETDEWEB)

    Cedola, A. [Istituto di Fotonica e Nanotecnologie-Consiglio Nazionale delle Ricerche (IFN-CNR), via Cineto Romano 42, I-00156 Roma (Italy); INFN, Sezione di Roma1, Piazzale Aldo Moro2, 00185 Rome (Italy)], E-mail: cedola@ifn.cnr.it; Bukreeva, I.; Lagomarsino, S. [Istituto di Fotonica e Nanotecnologie-Consiglio Nazionale delle Ricerche (IFN-CNR), via Cineto Romano 42, I-00156 Roma (Italy); INFN, Sezione di Roma1, Piazzale Aldo Moro2, 00185 Rome (Italy); Petrillo, V.; Maroli, C. [Universita di Milano, Physics Department and INFN Sezione di Milano Via Celoria 16, 20133 Milano (Italy)

    2009-09-01

    The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the specific case of micro-calcifications detection.

  16. Theoretical considerations for X-ray phase contrast mammography by Thomson source

    International Nuclear Information System (INIS)

    Cedola, A.; Bukreeva, I.; Lagomarsino, S.; Petrillo, V.; Maroli, C.

    2009-01-01

    The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the specific case of micro-calcifications detection.

  17. Equation-of-State Measurements of Resorcinol Formaldehyde Foam Using Imaging X-Ray Thomson Spectrometer

    Science.gov (United States)

    Belancourt, Patrick; Theobald, W.; Keiter, P. A.; Collins, T. J. B.; Bonino, M. J.; Kozlowski, P.; Drake, R. P.

    2015-11-01

    Understanding the equation of state of materials under shocked conditions is important for laboratory astrophysics and high-energy-density physics experiments. This talk will focus on experiments dedicated to developing a platform for measuring the equation of state of shocked foams on OMEGA EP. The foam used in the development of this platform is resorcinol formaldehyde foam with an initial density of 0.34 g/cc. One OMEGA EP beam drives a shock into the foam, while the remaining three beams irradiate a nickel foil to create the x-ray backlighter. The primary diagnostic for this platform, the imaging x-ray Thomson spectrometer (IXTS), spectrally resolves the scattered x-ray beam while imaging in one spatial dimension. The IXTS is ideally suited to measure plasma conditions upstream, downstream and at the shock front in the foam. Preliminary results from these experiments will be shown. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944, the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas DE-NA0001840, and by the National Laser User Facility Program DE-NA0000850.

  18. Non-coherent continuum scattering as a line polarization mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Del Pino Alemán, T.; Manso Sainz, R.; Trujillo Bueno, J., E-mail: tanausu@iac.es, E-mail: rsainz@iac.es, E-mail: jtb@iac.es [Instituto de Astrofísica de Canarias, E-38205 La Laguna, Tenerife (Spain)

    2014-03-20

    Line scattering polarization can be strongly affected by Rayleigh scattering at neutral hydrogen and Thomson scattering at free electrons. Often a depolarization of the continuum results, but the Doppler redistribution produced by the continuum scatterers, which are light (hence, fast), induces more complex interactions between the polarization in spectral lines and in the continuum. Here we formulate and solve the radiative transfer problem of scattering line polarization with non-coherent continuum scattering consistently. The problem is formulated within the spherical tensor representation of atomic and light polarization. The numerical method of solution is a generalization of the Accelerated Lambda Iteration that is applied to both the atomic system and the radiation field. We show that the redistribution of the spectral line radiation due to the non-coherence of the continuum scattering may modify the shape of the emergent fractional linear polarization patterns significantly, even yielding polarization signals above the continuum level in intrinsically unpolarizable lines.

  19. Quintessence Reissner Nordström Anti de Sitter Black Holes and Joule Thomson Effect

    Science.gov (United States)

    Ghaffarnejad, H.; Yaraie, E.; Farsam, M.

    2018-02-01

    In this work we investigate corrections of the quintessence regime of the dark energy on the Joule-Thomson (JT) effect of the Reissner Nordström anti de Sitter (RNAdS) black hole. The quintessence dark energy has equation of state as p q = ω ρ q in which -1Hawking temperature on the T-P plan. We determine position of the inverse point versus different numerical values of the mass M and the charge Q of the quintessence AdS RN black hole. The cooling-heating phase transition (JT effect) is happened for M > Q in which the causal singularity is still covered by the horizon. Our calculations show sensitivity of the inverse point {T i , P i } position on the T-P plan to existence of the quintessence dark energy just for large numerical values of the AdS RN black holes charge Q. In other words the quintessence dark energy dose not affect on position of the inverse point when the AdS RN black hole takes on small charges.

  20. Thermodynamic Analysis of TEG-TEC Device Including Influence of Thomson Effect

    Science.gov (United States)

    Feng, Yuanli; Chen, Lingen; Meng, Fankai; Sun, Fengrui

    2018-01-01

    A thermodynamic model of a thermoelectric cooler driven by thermoelectric generator (TEG-TEC) device is established considering Thomson effect. The performance is analyzed and optimized using numerical calculation based on non-equilibrium thermodynamic theory. The influence characteristics of Thomson effect on the optimal performance and variable selection are investigated by comparing the condition with and without Thomson effect. The results show that Thomson effect degrades the performance of TEG-TEC device, it decreases the cooling capacity by 27 %, decreases the coefficient of performance (COP) by 19 %, decreases the maximum cooling temperature difference by 11 % when the ratio of thermoelectric elements number is 0.6, the cold junction temperature of thermoelectric cooler (TEC) is 285 K and the hot junction temperature of thermoelectric generator (TEG) is 450 K. Thomson effect degrades the optimal performance of TEG-TEC device, it decreases the maximum cooling capacity by 28 % and decreases the maximum COP by 28 % under the same junction temperatures. Thomson effect narrows the optimal variable range and optimal working range. In the design of the devices, limited-number thermoelectric elements should be more allocated appropriately to TEG when consider Thomson effect. The results may provide some guidelines for the design of TEG-TEC devices.

  1. Mark Thomson presents the book "Modern Particle Physics"

    CERN Multimedia

    2013-01-01

    Tuesday 5 November 2013 at 4 p.m. in the Library, Bldg. 52 1-052 This new textbook covers all the main aspects of modern particle physics, providing a clear connection between the theory and recent experimental results, including the recent discovery of a Higgs boson and the most recent developments in neutrino physics. It provides a comprehensive and self-contained description of the Standard Model of particle physics suitable for upper-level undergraduate students and graduate students studying experimental particle physics. Physical theory is introduced in a relatively straightforward manner with step-by-step mathematical derivations. In each chapter, fully worked examples link the theory to central experimental results in contemporary particle physics. Modern Particle Physics, by Mark Thomson, Cambridge University Press, 2013, ISBN 9781107034266. *Coffee will be served from 3.30 p.m.*

  2. Multiple compton scattering effect on the spectrum of X-ray radiation. Monte-Carlo computations

    International Nuclear Information System (INIS)

    Pozdnyakov, L.A.; Sobol', I.M.; Syunyaev, R.A.; AN SSSR, Moscow. Inst. Prikladnoj Matematiki)

    1977-01-01

    Computation of the X-ray radiation spectrum forming at multiple scattering of low-frequency photons on relativistic electrons is carried out. A spherical cloud of relativistic plasma with optical depth on Thomson scattering tau and a given temperature of Maxwellian electrons kTsub(e) is considered. There is a point source of low frequency radiation in the centre of the cloud with a Planckian spectrum. Monte-Carlo computations and analytical estimates show that in the case of small optical depth tau < 1, the radiation escaping from the cloud has a power-law spectrum Isub(ν) approximately νsup(-α) where α is the spectral index. In the case of an optically thick cloud, the escaping radiation spectrum tends to the Wien equilibrium shape. The energy loss rate of the cloud is computed. The transfer of hard radiation from a central point source through a plasma cloud with kTsub(e) approximately 3 keV is considered. Monte-Carlo techniques for computing such problems are decribed

  3. Fitting of the Thomson scattering density and temperature profiles on the COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Štefániková, Estera; Peterka, Matěj; Böhm, Petr; Bílková, Petra; Aftanas, Milan; Sos, M.; Urban, Jakub; Hron, Martin; Pánek, Radomír

    2016-01-01

    Roč. 87, č. 11 (2016), č. článku 11E536. ISSN 0034-6748. [Topical Conference on High-Temperature Plasma Diagnostics 2016/21./. Madison, Wisconsin, 05.06.2016-09.06.2016] R&D Projects: GA ČR(CZ) GA14-35260S; GA MŠk(CZ) 8D15001; GA MŠk(CZ) LM2015045 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:61389021 Keywords : pedestal * fitting * instrument function Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.515, year: 2016 http://scitation.aip.org/content/aip/journal/rsi/87/11/10.1063/1.4961554

  4. Design advances of the Core Plasma Thomson Scattering diagnostic for ITER.

    Czech Academy of Sciences Publication Activity Database

    Scannell, R.; Maslov, M.; Naylor, G.; O’Gorman, T.; Kempenaars, M.; Carr, M.; Bílková, Petra; Böhm, Petr; Giudicotti, L.; Pasqualotto, R.; Bassan, M.; Vayakis, G.; Walsh, M.; Huxford, R.

    2017-01-01

    Roč. 12, November (2017), č. článku C11010. ISSN 1748-0221. [International Symposium on Laser-Aided Plasma Diagnostics (LAPD2017) /18./. Prague, 24.09.2017-28.09.2017] Institutional support: RVO:61389021 Keywords : Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - interferometry * spectroscopy and imaging Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/11/C11010/pdf

  5. Velocity-space tomography of fusion plasmas by collective Thomson scattering of gyrotron radiation

    DEFF Research Database (Denmark)

    Salewski, Mirko; Jacobsen, A.S.; Jensen, Thomas

    2016-01-01

    We propose a diagnostic capable of measuring 2D fast-ion velocity distribution functions 푓2퐷푣 in the MeV-range in magnetized fusion plasmas. Today velocity-space tomography based on fast-ion D훼 spectroscopy is regularly used to measure 푓2퐷푣 for ion energies below 100 keV. Unfortunately, the signal...

  6. Cavity Enhanced Thomson Scattering Diagnostic for Electron Measurements in Weakly Ionized Discharges

    Data.gov (United States)

    National Aeronautics and Space Administration — The research plan for the present NSTRF proposal focuses on a new laser diagnostic for measurement of electrons (density and temperature) in electric propulsion (EP)...

  7. The prospect for fuel ion ratio measurements in ITER by collective Thomson scattering

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Korsholm, Søren Bang; Nielsen, Stefan Kragh

    2012-01-01

    in CTS spectra have been suggested as the basis for a new fuel ion ratio diagnostic which would be well suited for reactor environments and capable of providing spatially resolved measurements in the plasma core. Such measurements were demonstrated in recent experiments in the TEXTOR tokamak. Here we...

  8. Outline of optical design and viewing geometry for divertor Thomson scattering on MAST upgrade

    Czech Academy of Sciences Publication Activity Database

    Hawke, J.; Scannell, R.; Harrison, J.; Huxford, R.; Böhm, Petr

    2013-01-01

    Roč. 8, č. 11 (2013), C11010-C11010 ISSN 1748-0221. [International Symposium Laser Aided Plasma Diagnostics/16./. Madison, 22.09.2013-26.09.2013] Institutional support: RVO:61389021 Keywords : Plasma diagnostics - interferometry * Spectroscopy and imaging * Optics * Plasma diagnostics - charged-particle spectroscopy Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.526, year: 2013 http://iopscience.iop.org/1748-0221/8/11/C11010/pdf/1748-0221_8_11_C11010.pdf

  9. Feasibility study for implementing an optical Thomson scattering system for studying photoionized plasmas on Z

    OpenAIRE

    Kozlowski, Pawel M.; Mancini, Roberto C.; Koepke, Mark E.

    2018-01-01

    Many astrophysical environments such as X-ray binaries, active galactic nuclei, and accretion disks of compact objects have photoionized plasmas. The strong photoionizing environment found near these bright X-ray sources can be produced in a scaled laboratory experiment, and direct measurements can form a testbed for spectroscopic models and photoionization codes used in analysis of these astrophysical objects. Such scaled experiments are currently being conducted using Ne filled gas cells on...

  10. Characterization of dust particles in the TEXTOR tokamak with Thomson scattering diagnostic

    NARCIS (Netherlands)

    Kantor, M.; Tsalas, M.; Litnovsky, A.; Rudakov, D.; Bozhenkov, S.; Ratynskaia, S.; Ashikawa, N.; Pospieszczyk, A.; Philipps, V.

    2013-01-01

    The presence of dust particles in a fusion plasma is recognized as a serious issue for safe and efficient operation of the ITER tokamak. The paper presents an in situ laser assisted method for characterization of dust from thermal emission of the particles. The method was developed in the TEXTOR

  11. X-ray Thomson scattering measurement of temperature in warm dense carbon

    Czech Academy of Sciences Publication Activity Database

    Falk, Kateřina; Fryer, C.L.; Gamboa, E. J.; Greeff, C.W.; Johns, H.M.; Schmidt, D.W.; Šmíd, Michal; Benage, J. F.; Montgomery, D. S.

    2017-01-01

    Roč. 57, č. 1 (2017), s. 47-53 ISSN 0741-3335 R&D Projects: GA MŠk EF15_008/0000162; GA MŠk LQ1606 Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : warm dense matter * equation of state * laser plasmas * dynamic compression * shock physics Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 2.392, year: 2016

  12. Engineering design of the ITER Collective Thomson Scattering diagnostic. Contract EFDA 06-1478

    DEFF Research Database (Denmark)

    Michelsen, Poul; Furtula, Vedran; Korsholm, Søren Bang

    This report describes the work done under EFDA contract 06-1478 (EFDA Ref.: TW6-TPDS-DIASUP10). The main part of the work has been focused on: 1) An outline plan for the full development of the CTS diagnostic for ITER, including specifications for future design tasks on the system and R&D tasks...

  13. Antenna design for fast ion collective Thomson scattering diagnostic for the international thermonuclear experimental reactor

    DEFF Research Database (Denmark)

    Leipold, Frank; Furtula, Vedran; Salewski, Mirko

    2009-01-01

    antenna is located behind the blankets and views the plasma through the gap between two blanket modules. The viewing gap has been modified to dimensions 30 × 500 mm2 to optimize the CTS signal. A 1:1 mock-up of the HFS mirror system was built. Measurements of the beam characteristics for millimeter......-waves at 60 GHz used in the mock-up agree well with the modeling....

  14. Recent results of collective Thomson scattering on TEXTOR and plans for CTS on ITER

    DEFF Research Database (Denmark)

    Korsholm, Søren Bang; Bindslev, Henrik; Furtula, Vedran

    perpendicular to the magnetic field. The feasibility study and conceptual design of this diagnostic was provided by the CTS group at Risø DTU. The development of the ITER CTS diagnostic builds on the experiences and expertise gained from the construction and current operation of the CTS diagnostic systems......) provides the possibility of revealing the velocity distribution of the confined fast ions along a given direction – resolved both in time and space. Recently, the ITER baseline design has been expanded to include the enabling of the front end of a fast ion CTS diagnostic system resolving dynamics...... on TEXTOR and ASDEX Upgrade. This contribution will briefly introduce the technique of CTS, give an overview of the results of the current diagnostic systems at TEXTOR, and present the chosen solution and the status of the design of the ITER CTS diagnostic system....

  15. Fast-ion dynamics in the TEXTOR tokamak measured by collective Thomson scattering

    DEFF Research Database (Denmark)

    Bindslev, Henrik; Nielsen, Stefan Kragh; Porte, L.

    2007-01-01

    ) and the slowdown after switch off of NBI are measured. The turn on phase of the NBI has, furthermore, been measured in plasmas with a range of electron densities and temperatures. All of these measurements are shown to be in good agreement with simple Fokker-Planck modelling. Bulk ion rotation velocity is also...

  16. Psühhofüsioloogilised mängud / Kaivo Thomson

    Index Scriptorium Estoniae

    Thomson, Kaivo, 1956-

    2002-01-01

    Rmt.: Thomson, Kaivo. Psühhofüsioloogilised mängud : teooria & värvitoonide, helikõrguste ja liikumiskiiruste eristamisvõime testimine ning arendamine meetodiga "WinPsycho 2000" (CD-1). Tartu : Atlex, 2001.

  17. Thomson, the right to life, and partial birth abortion or two MULES for Sister Sarah.

    Science.gov (United States)

    Alward, P

    2002-04-01

    In this paper, I argue that Thomson's famous attempt to reconcile the fetus's putative right to life with robust abortion rights is not tenable. Given her view, whether or not an abortion violates the fetus's right to life depends on the abortion procedure utilised. And I argue that Thomson's view implies that any late term abortion that involves feticide is impermissible. In particular, this would rule out the partial birth abortion technique which has been so controversial of late.

  18. Predicted precision of ion temperature and impurity fractional density measurements using the JET collective scattering diagnostic

    International Nuclear Information System (INIS)

    Orsitto, F.

    1992-11-01

    In a previous investigation the possibility of measuring the bulk ion temperature was considered in detail, in the context of the proposed Thomson scattering diagnostic for fast ions and alpha particles in the Joint European Torus project. In this report we give an affirmative answer to the question of whether good precision can be obtained in the simultaneous determination of the temperatures and densities of plasma ions from a collective scattering experiment provided some conditions are satisfied. (Author)

  19. Mixture optimization for mixed gas Joule-Thomson cycle

    Science.gov (United States)

    Detlor, J.; Pfotenhauer, J.; Nellis, G.

    2017-12-01

    An appropriate gas mixture can provide lower temperatures and higher cooling power when used in a Joule-Thomson (JT) cycle than is possible with a pure fluid. However, selecting gas mixtures to meet specific cooling loads and cycle parameters is a challenging design problem. This study focuses on the development of a computational tool to optimize gas mixture compositions for specific operating parameters. This study expands on prior research by exploring higher heat rejection temperatures and lower pressure ratios. A mixture optimization model has been developed which determines an optimal three-component mixture based on the analysis of the maximum value of the minimum value of isothermal enthalpy change, ΔhT , that occurs over the temperature range. This allows optimal mixture compositions to be determined for a mixed gas JT system with load temperatures down to 110 K and supply temperatures above room temperature for pressure ratios as small as 3:1. The mixture optimization model has been paired with a separate evaluation of the percent of the heat exchanger that exists in a two-phase range in order to begin the process of selecting a mixture for experimental investigation.

  20. The genus Rosalba Thomson, 1864 (Coleoptera, Cerambycidae, Lamiinae, Apomecynini).

    Science.gov (United States)

    Santos-Silva, Antonio; Galileo, Maria Helena M; Joly, Luis J; Tavakilian, GÉrard L

    2018-02-26

    Nineteen new species are described: Rosalba wappesi, from Bolivia; R. giesberti, from Bolivia; R. skillmani, from Bolivia; R. lingafelteri, from Bolivia; R. senecauxi, from French Guiana; R. dalensi, from French Guiana; R. giuglarisi, from French Guiana; R. nearnsi, from French Guiana; R. cerdai, from French Guiana; R. gaianii, from Venezuela; R. pittieri, from Venezuela; R. clinei, from Bolivia and Brazil; R. morrisi, from Costa Rica and Panama; R. schneppi, from Panama; R. birai, from Colombia; R. stenodesma, from Venezuela and French Guiana; R. similis, from Peru and Ecuador; R. bezarki, from Ecuador; and R.seraisorum, from Ecuador and Brazil (Amazonas). The following new synonymies are established: Aletretia dissimilis Belon, 1903 = A. fimbriata Belon, 1903; Aletretia consobrina Melzer, 1934, Rosalba gounellei Galileo Martins, 2013 and Rosalba vanini Galileo Martins, 2013 = Aletretia inscripta Bates, 1866; Aletretia mediofasciata Breuning, 1943 = Aletretia bucki Melzer, 1934; Aletretia peraffinis Breuning, 1940 = Aletretia approximata Melzer, 1934. The following species are redescribed: Rosalba strandiella (Breuning, 1940); and Rosalba rufescens (Breuning, 1940). The following new records are reported: Rosalba strandiella for Bolivia; R. strandi (Breuning, 1943) from the Brazilian states of São Paulo, Paraná and Santa Catarina; R. inscripta from Peru and the Brazilian state of Acre; R. smaragdina (Breuning, 1940) from the Brazilian state of Minas Gerais; R. obliqua (Thomson, 1868) from Brazil; and Rosalba fimbriata (Belon, 1903) from Ecuador.

  1. A new high-resolution small-angle X-ray scattering apparatus using a fine-focus rotating anode, point-focusing collimation and a position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Yoda, O.

    1984-01-01

    A high-resolution small-angle X-ray scattering camera has been built, which has the following features. (i) The point collimation optics employed allows the scattering cross section of the sample to be directly measured without corrections for desmearing. (ii) A small-angle resolution better than 0.5 mrad is achieved with a camera length of 1.6 m. (iii) A high photon flux of 0.9 photons μs -1 is obtained on the sample with the rotating-anode X-ray generator operated at 40 kV-30 mA. (iv) Incident X-rays are monochromatized by a bent quartz crystal, which makes the determination of the incident X-ray intensity simple and unambiguous. (v) By rotation of the position-sensitive proportional counter around the direct beam, anisotropic scattering patterns can be observed without adjusting the sample. Details of the design and performance are presented with some applications. (Auth.)

  2. 78 FR 30797 - Proposed Amendment of Class E Airspace; Point Thomson, AK

    Science.gov (United States)

    2013-05-23

    ..., ``Environmental Impacts: Policies and Procedures'' prior to any FAA final regulatory action. List of Subjects in... Navigation (RNAV) Global Positioning System (GPS) standard instrument approach procedures at the airport. The... proposal to the U.S. Department of Transportation, Docket Operations, M-30, West Building Ground Floor...

  3. Advantages of using gyrotron scattering for alpha particle diagnostics

    International Nuclear Information System (INIS)

    Woskoboinikow, P.P.; Cohn, D.R.; Machuzak, J.S.; Myer, R.C.; Rhee, R.Y.

    1987-07-01

    Millimeter-wave gyrotron collective Thomson scattering can be an effective diagnostic technique for the study of alpha particle behavior in ignited plasmas. The measurement of alpha particle density, velocity distribution, and alpha particle induced plasma instabilities can be accomplished with both spatial and temporal resolution. Advantages include long pulse operation which can make possible very high signal to noise ratios and use of millimeter waves which maximizes the Doppler shifted scattered signal in WHz -1 and makes possible scattering angles up to 180 0 . Extraordinary mode scattering at approximately 60 and 200 GHz would be used in TFTR and CIT respectively, and 140 GHz ordinary mode scattering in JET. 8 refs., 1 fig

  4. Thermal-neutron multiple scattering: critical double scattering

    International Nuclear Information System (INIS)

    Holm, W.A.

    1976-01-01

    A quantum mechanical formulation for multiple scattering of thermal-neutrons from macroscopic targets is presented and applied to single and double scattering. Critical nuclear scattering from liquids and critical magnetic scattering from ferromagnets are treated in detail in the quasielastic approximation for target systems slightly above their critical points. Numerical estimates are made of the double scattering contribution to the critical magnetic cross section using relevant parameters from actual experiments performed on various ferromagnets. The effect is to alter the usual Lorentzian line shape dependence on neutron wave vector transfer. Comparison with corresponding deviations in line shape resulting from the use of Fisher's modified form of the Ornstein-Zernike spin correlations within the framework of single scattering theory leads to values for the critical exponent eta of the modified correlations which reproduce the effect of double scattering. In addition, it is shown that by restricting the range of applicability of the multiple scattering theory from the outset to critical scattering, Glauber's high energy approximation can be used to provide a much simpler and more powerful description of multiple scattering effects. When sufficiently close to the critical point, it provides a closed form expression for the differential cross section which includes all orders of scattering and has the same form as the single scattering cross section with a modified exponent for the wave vector transfer

  5. Application of the Banach Fixed-Point Theorem to the Scattering Problem at a Nonlinear Three-Layer Structure with Absorption

    Directory of Open Access Journals (Sweden)

    V. S. Serov

    2010-01-01

    Full Text Available A method based on the Banach fixed-point theorem is proposed for obtaining certain solutions (TE-polarized electromagnetic waves of the Helmholtz equation describing the reflection and transmission of a plane monochromatic wave at a nonlinear lossy dielectric film situated between two lossless linear semiinfinite media. All three media are assumed to be nonmagnetic and isotropic. The permittivity of the film is modelled by a continuously differentiable function of the transverse coordinate with a saturating Kerr nonlinearity. It is shown that the solution of the Helmholtz equation exists in form of a uniformly convergent sequence of iterations of the equivalent Volterra integral equation. Numerical results are presented.

  6. 75 FR 1015 - Directing Certain Actions with Respect to Acquisition and Use of Thomson Correctional Center to...

    Science.gov (United States)

    2010-01-08

    ... expeditiously as possible with respect to the facility known as the Thomson Correctional Center (TCC) in Thomson, Illinois: 1. The Attorney General shall acquire and activate the TCC as a United States Penitentiary, which.... The Attorney General shall also provide to the Department of Defense a sufficient portion of the TCC...

  7. Diffuse scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kostorz, G. [Eidgenoessische Technische Hochschule, Angewandte Physik, Zurich (Switzerland)

    1996-12-31

    While Bragg scattering is characteristic for the average structure of crystals, static local deviations from the average lattice lead to diffuse elastic scattering around and between Bragg peaks. This scattering thus contains information on the occupation of lattice sites by different atomic species and on static local displacements, even in a macroscopically homogeneous crystalline sample. The various diffuse scattering effects, including those around the incident beam (small-angle scattering), are introduced and illustrated by typical results obtained for some Ni alloys. (author) 7 figs., 41 refs.

  8. Simulation of PET scan timings for receptor occupancy studies of CNS drugs: a simple fixed-time design performed as well as scattered time point designs.

    Science.gov (United States)

    Lee, Jongtae; Jeon, Sangil; Hong, Taegon; Han, Seunghoon; Yim, Dong-Seok

    2015-11-01

    This study aimed to determine the effect of PET scan timings on the reliability of occupancy parameter estimates and to identify the scan timing design that gives the most reliable occupancy parameter estimates. We compared the performance of designs with various sets of sampling time points using the stochastic simulation and estimation method in Perl-speaks-NONMEM. Biases, relative standard errors, relative estimation errors, and root mean square errors were used to compare the performance of designs. Unlike the results of a previous report, we found that rather complicated designs where each subject or group of subjects are allocated to different scan timings were not superior to the simple, conventional fixed-time designs regardless of whether effect compartment or receptor binding models were used. We conclude that the conventional fixed-time designs that have been used so far may give robust PD parameter estimates for occupancy data obtained from human PET studies of CNS drugs.

  9. Experimental study of TJ-1 plasma using scattering and radiation emission techniques; Analisis experimental del plasma TJ-1 con tecnicas de scattering y emision de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Pardo, C.; Zurro, B.

    1987-07-01

    The Thomson scattering system of TJ-1 is described in detail. The radial profiles of Te and ne obtained in TJ-1 discharges are presented. This data make possible to deduce characteristic parameters of the plasma confinement in this machine, as energy confinement times, Zeff B. Using also radiation measurements (global and in the visible range) we obtained the particle confinement time and Zeff without non experimental assumptions. (Author) 52 refs.

  10. Detection of cardiac biomarkers exploiting surface enhanced Raman scattering (SERS) using a nanofluidic channel based biosensor towards coronary point-of-care diagnostics

    Science.gov (United States)

    Benford, Melodie E.; Wang, Miao; Kameoka, Jun; Coté, Gerard L.

    2009-02-01

    According to the World Health Organization, cardiovascular disease is the most common cause of death in the world. In the US, over 115 million people visit the emergency department (ED), 5 million of which may have acute coronary syndrome (ACS). Cardiac biomarkers can provide early identification and diagnosis of ACS, and can provide information on the prognosis of the patient by assessing the risk of death. In addition, the biomarkers can serve as criteria for admission, indicate possibility of re-infarction, or eliminate ACS as a diagnosis altogether. We propose a SERSbased multi-marker approach towards a point-of-care diagnostic system for ACS. Using a nanofluidic device consisting of a microchannel leading into a nanochannel, we formed SERS active sites by mechanically aggregating gold particles (60 nm) at the entrance to the nanochannel (40nm×1μm). The induced capillary flow produces a high density of aggregated nanoparticles at this precise region, creating areas with enhanced electromagnetic fields within the aggregates, shifting the plasmon resonance to the near infrared region, in resonance with incident laser wavelength. With this robust sensing platform, we were able to obtain qualitative information of brain natriuretic peptide (biomarker of ventricular dysfunction or pulmonary stress), troponin I (biomarker of myocardial necrosis), and C-reactive protein (biomarker of inflammation potentially caused by atherosclerosis).

  11. Verification of the Thomson-Onsager reciprocity relation for spin caloritronics

    NARCIS (Netherlands)

    Dejene, F. K.; Flipse, J.; van Wees, B. J.

    2014-01-01

    We investigate the Thomson-Onsager relation between the spin-dependent Seebeck and spin-dependent Peltier effect. To maintain identical device and measurement conditions we measure both effects in a single Ni80Fe20/Cu/Ni80Fe20 nanopillar spin valve device subjected to either an electrical or a

  12. Joseph John Thomson's models of matter and radiation in the early 1890s.

    Science.gov (United States)

    Bordoni, Stefano

    In the late nineteenth century, Joseph John Thomson moved away from Maxwell's specific theoretical models of matter and energy, even though he continued to rely on the general framework of Maxwell's electromagnetic theory. In his 1893 book, he accomplished the conceptual drift towards a discrete model for matter, electricity, and fields. In Thomson's model, energy was linked to tubes of force, in particular to the aether contained in them and surrounding them: the energy was the kinetic energy of aether, of both a rotational and translational kind. Starting from Maxwell's electromagnetic fields, namely stresses propagating through a continuous solid medium, Thomson arrived at a representation of fields as a sea of discrete units carrying energy and momentum. He tried to transform Maxwell's theory into a unified picture in which atomic models of matter stood beside atomic models of fields. In 1904 his interpretation of X-rays was based on the integration between two complementary features of electromagnetic radiation, the continuity and the discreteness, and on some kind of fibrous aether. In recent secondary literature, the problematic conceptual link between J. J. Thomson's theory and contemporary theories on electromagnetic radiation has been underestimated. On the contrary, in the first half of the twentieth century, some physicists inquired into that link, and a widespread debate emerged, misunderstandings included.

  13. Sensitivity of Micromachined Joule-Thomson Cooler to Clogging Due to Moisture

    NARCIS (Netherlands)

    Cao, Haishan; Vanapalli, Srinivas; Holland, Herman J.; Vermeer, Cristian Hendrik; ter Brake, Hermanus J.M.

    2015-01-01

    A major issue in long-term operation of micromachined Joule-Thomson coolers is the clogging of the microchannels and/or the restriction due to the deposition of water molecules present in the working fluid. In this study, we present the performance of a microcooler operated with nitrogen gas with

  14. 3 CFR - Directing Certain Actions With Respect to Acquisition and Use of Thomson Correctional Center To...

    Science.gov (United States)

    2010-01-01

    ... Correctional Center (TCC) in Thomson, Illinois: 1. The Attorney General shall acquire and activate the TCC as a... sufficient portion of the TCC to serve as a detention facility to be operated by the Department of Defense in... General, shall prepare the TCC for secure housing of detainees currently held at the Guantanamo Bay Naval...

  15. Optimization of the working fluid for a soprtion-based Joule-Thomson cooler

    NARCIS (Netherlands)

    Wu, Roger; Zalewski, D.R.; Vermeer, Cristian Hendrik; ter Brake, Hermanus J.M.

    2013-01-01

    Sorption-based Joule–Thomson coolers operate vibration-free, have a potentially long life time, and cause no electromagnetic interference. Therefore, they are appealing to a wide variety of applications, such as cooling of low-noise amplifiers, superconducting electronics, and optical detectors. The

  16. A New Version of an Old Demonstration Experiment Using the Elihu Thomson Jumping Ring Apparatus

    Science.gov (United States)

    Foster, Theodore; Cary, Arthur; Mottmann, John; van Wyngaarden, Willem

    2016-01-01

    The goal of this paper is to make more widely known an eye-catching demonstration experiment in which a hanging conducting can is made to spin when placed near the iron core of an Elihu Thomson "jumping ring" apparatus. An explanation is given based on Faraday's law of induced voltages and the magnetic forces due to the core's fields…

  17. A miniature Joule-Thomson cooler for optical detectors in space

    NARCIS (Netherlands)

    Derking, J.H.; Holland, Herman J.; Tirolien, T.; ter Brake, Hermanus J.M.

    2012-01-01

    The utilization of single-stage micromachined Joule-Thomson (JT) coolers for cooling small optical detectors is investigated. A design of a micromachined JT cold stage–detector system is made that focuses on the interface between a JT cold stage and detector, and on the wiring of the detector. Among

  18. Optimization of the working fluid in a Joule-Thomson cold stage

    NARCIS (Netherlands)

    Derking, J.H.; ter Brake, Hermanus J.M.; Sirbi, A.; Linder, M.; Rogalla, Horst

    2009-01-01

    Vibration-free miniature Joule–Thomson (JT) coolers are of interest for cooling a wide variety of devices, including low-noise amplifiers, semiconducting and superconducting electronics, and small optical detectors used in space applications. For cooling such devices, coolers are needed which have

  19. Quasiresonant scattering

    International Nuclear Information System (INIS)

    Hategan, Cornel; Comisel, Horia; Ionescu, Remus A.

    2004-01-01

    The quasiresonant scattering consists from a single channel resonance coupled by direct interaction transitions to some competing reaction channels. A description of quasiresonant Scattering, in terms of generalized reduced K-, R- and S- Matrix, is developed in this work. The quasiresonance's decay width is, due to channels coupling, smaller than the width of the ancestral single channel resonance (resonance's direct compression). (author)

  20. Experimental study of TJ-1 plasma using scattering and radiation emission techniques

    International Nuclear Information System (INIS)

    Pardo, C.; Zurro, B.

    1987-01-01

    The Thomson scattering system of TJ-1 is described in detail. The radial profiles of Te and ne obtained in TJ-1 discharges are presented. This data make possible to deduce characteristic parameters of the plasma confinement in this machine, as energy confinement times, Zeff B. Using also radiation measurements (global and in the visible range) we obtained the particle confinement time and Zeff without non experimental assumptions. (Author) 52 refs

  1. Scattering properties of point dipole interactions

    DEFF Research Database (Denmark)

    Zolotaryuk, Alexander; Christiansen, Peter Leth; Iermakova, S.V.

    2006-01-01

    dipole interactions with a renormalized coupling constant are analysed. Depending on the parameter values, all these interactions being self-adjoint extensions of the one-dimensional Schrodinger operator are shown to be divided into four types: (i) interactions will full transparency, (ii) non...

  2. Scattering theory

    International Nuclear Information System (INIS)

    Sitenko, A.

    1991-01-01

    This book emerged out of graduate lectures given by the author at the University of Kiev and is intended as a graduate text. The fundamentals of non-relativistic quantum scattering theory are covered, including some topics, such as the phase-function formalism, separable potentials, and inverse scattering, which are not always coverded in textbooks on scattering theory. Criticisms of the text are minor, but the reviewer feels an inadequate index is provided and the citing of references in the Russian language is a hindrance in a graduate text

  3. Critical scattering

    International Nuclear Information System (INIS)

    Stirling, W.G.; Perry, S.C.

    1996-01-01

    We outline the theoretical and experimental background to neutron scattering studies of critical phenomena at magnetic and structural phase transitions. The displacive phase transition of SrTiO 3 is discussed, along with examples from recent work on magnetic materials from the rare-earth (Ho, Dy) and actinide (NpAs, NpSb, USb) classes. The impact of synchrotron X-ray scattering is discussed in conclusion. (author) 13 figs., 18 refs

  4. Critical scattering

    Energy Technology Data Exchange (ETDEWEB)

    Stirling, W.G. [Liverpool Univ., Dep. of Physics, Liverpool (United Kingdom); Perry, S.C. [Keele Univ. (United Kingdom). Dept. of Physics

    1996-12-31

    We outline the theoretical and experimental background to neutron scattering studies of critical phenomena at magnetic and structural phase transitions. The displacive phase transition of SrTiO{sub 3} is discussed, along with examples from recent work on magnetic materials from the rare-earth (Ho, Dy) and actinide (NpAs, NpSb, USb) classes. The impact of synchrotron X-ray scattering is discussed in conclusion. (author) 13 figs., 18 refs.

  5. Thomson parabola spectrometer for energetic ions emitted from sub-ns laser generated plasmas

    Czech Academy of Sciences Publication Activity Database

    Cutroneo, M.; Torrisi, L.; Andó, L.; Cavallaro, S.; Ullschmied, Jiří; Krása, Josef; Margarone, Daniele; Velyhan, Andriy; Krouský, Eduard; Pfeifer, Miroslav

    2013-01-01

    Roč. 53, č. 2 (2013), s. 138-141 ISSN 1210-2709 R&D Projects: GA MŠk LM2010014 Institutional research plan: CEZ:AV0Z20430508; CEZ:AV0Z10100523 Keywords : Thomson parabola spectrometer * high intensity laser * focal position * Opera 3D Tosca code * simulation Subject RIV: BL - Plasma and Gas Discharge Physics; BL - Plasma and Gas Discharge Physics (FZU-D) http://ctn.cvut.cz/ap/index.php?idissue=85

  6. Records of the genus Micrambe Thomson, 1863 (Coleoptera, Cryptophagidae) from Madagascar and Réunion Island

    OpenAIRE

    Otero,Carlos; Pereira,José Manuel

    2017-01-01

    A study on the genus Micrambe Thomson, 1863 (Coleoptera, Cryptophagidae) from Madagascar and Réunion is presented. Six species are hitherto known from these countries: M. apicalis Grouvelle, M. brevitarsis Bruce, M. consors Grouvelle, M. madagascariensis Grouvelle, M. modesta (Grouvelle), and M. reuninensis Lyubarsky. A new species, M. leonardoi sp. n., is formally described from Boorg-Murat, Réunion Island. A key is presented to enable their identification. Micrambe consors Grouvelle previou...

  7. A taxonomic review of Korean Liogluta Thomson (Coleoptera, Staphylinidae, Aleocharinae) with descriptions of three new species.

    Science.gov (United States)

    Lee, Seung-Gyu; Ahn, Kee-Jeong

    2016-11-15

    A taxonomic review of the Liogluta Thomson in Korea is presented. The genus is represented in Korea by eight species including three new species, L. changwhani Lee & Ahn, sp. nov., L. jinilli Lee & Ahn, sp. nov. and L. rufescens Lee & Ahn, sp. nov. Two species [L. distans (Sharp) and L. ursi (Sawada)] are new to the Korean peninsula and L. pyonganica is recorded for the first time in South Korea. A key, descriptions, habitus photographs and illustrations of the diagnostic characters are provided.

  8. Ultra-high temperature stability Joule-Thomson cooler with capability to accomodate pressure variations

    Science.gov (United States)

    Bard, Steven (Inventor); Wu, Jiunn-Jeng (Inventor); Trimble, Curtis A. (Inventor)

    1992-01-01

    A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.

  9. Gyrotron scattering from non-thermal fluctuations in the Tara Tandem Mirror

    International Nuclear Information System (INIS)

    Machuzak, J.S.; Myer, R.C.; Woskoboinikow, P.P.

    1987-09-01

    A 137 GHz, ∼0.4 kW, 75 ms pulsed gyrotron has been used for collective Thomson scattering in the Tara Tandem Mirror plug cell at MIT. Scattering from ion cyclotron waves during ion cyclotron resonance frequency (ICRF) heating, ion Bernstein wave harmonics, and plasma fluctuations possibly due to microinstabilities have been observed. The observed harmonic nature of the ion Bernstein waves may be due to an enhanced ion thermal frequency spectrum in an ICRF heated plasma. 6 refs., 1 fig

  10. Nonlinear Spectral Signatures and Spatiotemporal Behavior of Stimulated Raman Scattering from Single Laser Speckles

    International Nuclear Information System (INIS)

    Vu, H.X.; Yin, L.; DuBois, D.F.; Bezzerides, B.; Dodd, E.S.

    2005-01-01

    Simulations are reported of the Thomson scatter spectrum of electrostatic waves (ESWs) excited in single laser hot spots by backward stimulated Raman scattering (BSRS). Under conditions similar those in the recent experiments of Kline et al. [Phys. Rev. Lett. 94, 175003 (2005)], a spectral streak, resulting from the trapping-induced frequency shift of the ESW, is found for high wave-number ESWs, similar to the observations. This shift and parametric frequency matching lead to isolated BSRS pulses. Modes with acoustic dispersion, resulting from the trapping-modified electron velocity distribution, can enhance the frequency range of the streak

  11. Flash of the Cathode Rays: A History of J J Thomson's Electron

    International Nuclear Information System (INIS)

    Rechenberg, Helmut

    1997-01-01

    The author, a senior physicist from Berkeley having some experience in historical accounts, covers well the standard story of J J Thomson's discovery of the electron, one hundred years ago. Starting from the investigations of cathode rays in Germany, France and mainly England, the successful path of J J is covered in some detail using available information (letters, notebooks, diaries, publications), as well as his later work on positive rays and the atomic model. Lesser emphasis is given to the parallel developments connected with the Zeeman effect. However, a synopsis of the story of β-rays, the measurement of the elementary charge and the rise of the Rutherford - Bohr nuclear model of the atom is included. Dahl presents the physical contents from the standard literature in a clear and convincing way. He illustrates the narrative with (well-chosen and well-reproduced) portraits of the people involved and sketches of their original apparatus. Hence the book can be recommended highly to physicists, who will be reminded of one of the most important events in the earlier history of their field. A broader public, including other scientists, and perhaps attentive high school graduates, might also benefit from the book, not to mention professional science historians (who may appreciate the detailed, reliable description of subtle experiments and their tricky interpretation). The author succeeds far less well in providing the general background (in the history of physics and beyond) of the Thomson story. The electron as a fundamental concept existed and was applied long before J Pluecker's discovery of cathodes rays (for example, by A-M Ampere and his successors), and the importance of the work by W Weber, F Neumann and R Clausius (to mention just a few scientists in the 19th century) is mainly suppressed. Dahl's treatment of P Lenard's work around 1900, for which Lenard won the Nobel prize before Thomson, is quite unfair. Further, Chapter 14 on the French N-rays and

  12. Electron Scattering

    International Nuclear Information System (INIS)

    Li, Xiaodong; Lee, Kyong Sei; Shaw, J.J.; Bahri, C.

    1990-01-01

    Electron scattering is one of the best probes available to us to probe the nucleus. It has revealed to us, with unprecedented accuracy, the charge and current distributions of nuclei. It has provided us with positive evidence for meson exchange currents. It was used to 'discover' the quark and it revealed to us that nucleons may be modified in the nuclear environment (EMC Effect). In short, electron scattering has revolutionized the study of nuclear physics. Several recent developments will insure that electron beams which will soon become availabe at CEBAF, Bates and elsewhere will make high-precision coincidence experiments possible. As the technology is becoming available, we are just beginning to exploit polarization degrees of freedom in our experiments. In this paper, we will introduce the formalism of electron scattering, review what we have learned in the past and look ahead toward the future

  13. Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Botto, D.J.; Pratt, R.H.

    1979-05-01

    The current status of Compton scattering, both experimental observations and the theoretical predictions, is examined. Classes of experiments are distinguished and the results obtained are summarized. The validity of the incoherent scattering function approximation and the impulse approximation is discussed. These simple theoretical approaches are compared with predictions of the nonrelativistic dipole formula of Gavrila and with the relativistic results of Whittingham. It is noted that the A/sup -2/ based approximations fail to predict resonances and an infrared divergence, both of which have been observed. It appears that at present the various available theoretical approaches differ significantly in their predictions and that further and more systematic work is required.

  14. Compton scattering from nuclei and photo-absorption sum rules

    International Nuclear Information System (INIS)

    Gorchtein, Mikhail; Hobbs, Timothy; Londergan, J. Timothy; Szczepaniak, Adam P.

    2011-01-01

    We revisit the photo-absorption sum rule for real Compton scattering from the proton and from nuclear targets. In analogy with the Thomas-Reiche-Kuhn sum rule appropriate at low energies, we propose a new 'constituent quark model' sum rule that relates the integrated strength of hadronic resonances to the scattering amplitude on constituent quarks. We study the constituent quark model sum rule for several nuclear targets. In addition, we extract the α=0 pole contribution for both proton and nuclei. Using the modern high-energy proton data, we find that the α=0 pole contribution differs significantly from the Thomson term, in contrast with the original findings by Damashek and Gilman.

  15. Application of virtual machine technology to real-time mapping of Thomson scattering data to flux coordinates for the LHD

    International Nuclear Information System (INIS)

    Emoto, Masahiko; Yoshida, Masanobu; Suzuki, Chihiro; Suzuki, Yasuhiro; Ida, Katsumi; Nagayama, Yoshio; Akiyama, Tsuyoshi; Kawahata, Kazuo; Narihara, Kazumichi; Tokuzawa, Tokihiko; Yamada, Ichihiro

    2012-01-01

    Highlights: ► We have developed a mapping system of the electron temperature profile to the flux coordinates. ► To increases the performance, multiple virtual machines are used. ► The virtual machine technology is flexible when increasing the number of computers. - Abstract: This paper presents a system called “TSMAP” that maps electron temperature profiles to flux coordinates for the Large Helical Device (LHD). Considering the flux surface is isothermal, TSMAP searches an equilibrium database for the LHD equilibrium that fits the electron temperature profile. The equilibrium database is built through many VMEC computations of the helical equilibria. Because the number of equilibria is large, the most important technical issue for realizing the TSMAP system is computational performance. Therefore, we use multiple personal computers to enhance performance when building the database for TSMAP. We use virtual machines on multiple Linux computers to run the TSMAP program. Virtual machine technology is flexible, allowing the number of computers to be easily increased. This paper discusses how the use of virtual machine technology enhances the performance of TSMAP calculations when multiple CPU cores are used.

  16. Comparison of collective Thomson scattering signals due to fast ions in ITER scenarios with fusion and auxiliary heating

    DEFF Research Database (Denmark)

    Salewski, Mirko; Asunta, O.; Eriksson, L.-G.

    2009-01-01

    functions of fast ions generated by NBI and ICRH are calculated for a steady-state ITER burning plasma equilibrium with the ASCOT and PION codes, respectively. The parameters for the auxiliary heating systems correspond to the design currently foreseen for ITER. The geometry of the CTS system for ITER...

  17. A New Procedure for Determination of Electron Temperatures and Electron Concentrations by Thomson Scattering and Analytical Plasmas

    Science.gov (United States)

    1988-10-28

    Spectrochim. Acta 40B, 1211 (1985). 24 30. K. A. MARSHALL and G. M. HIEFTJE, Spectrochim. Acca (submitted, 1987). 31. H. J. KUNZE, Plasma Diagnostics, Ed...13 0,47689017-16 0 .4 F6 S6 7 E.16 26 Table 2. Correction table for Nd/YAG laser. Real (true) Te (top line) and Ne (left column) values and

  18. High-resolution Thomson scattering system on the COMPASS tokamak: Evaluation of plasma parameters and error analysis

    Czech Academy of Sciences Publication Activity Database

    Aftanas, Milan; Böhm, Petr; Bílková, Petra; Weinzettl, Vladimír; Zajac, Jaromír; Žáček, František; Stöckel, Jan; Hron, Martin; Pánek, Radomír; Scannell, R.; Walsh, M.

    2012-01-01

    Roč. 83, č. 10 (2012), 10E350-10E350 ISSN 0034-6748. [Topical Conference High-Temperature Plasma Diagnostics/19./. Monte rey, 06.05.2012-10.05.2012] R&D Projects: GA ČR GA202/09/1467; GA MŠk 7G10072 Institutional research plan: CEZ:AV0Z20430508 Keywords : error analysis * Monte Carlo method s * plasma density * plasma diagnostics * plasma temperature * plasma toroidal confinement * Tokamak devices Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.602, year: 2012 http://dx.doi.org/10.1063/1.4743956

  19. Fast ion measurements by collective Thomson scattering in TEXTOR and ASDEX Upgrade and proposal for the ITER CTS system

    DEFF Research Database (Denmark)

    Korsholm, Søren Bang; Bindslev, Henrik; Furtula, Vedran

    perpendicular to the magnetic field. The feasibility study and conceptual design of this diagnostic was provided by the CTS group at Risø DTU. The development of the ITER CTS diagnostic builds on the experiences and expertise gained from the construction and current operation of the CTS diagnostic systems......) provides the possibility of revealing the velocity distribution of the confined fast ions along a given direction – resolved both in time and space. Recently, the ITER baseline design has been expanded to include the enabling of the front end of a fast ion CTS diagnostic system resolving dynamics...... on TEXTOR and ASDEX Upgrade. This contribution will briefly introduce the technique of CTS, give an overview of the results of the current diagnostic systems at TEXTOR and ASDEX Upgrade, and present the chosen solution and the status of the design of the ITER CTS diagnostic system....

  20. The influence of Thomson effect in the performance optimization of a two stage thermoelectric cooler

    Science.gov (United States)

    Kaushik, S. C.; Manikandan, S.

    2015-12-01

    The exoreversible and irreversible thermodynamic models of a two stage thermoelectric cooler (TTEC) considering Thomson effect in conjunction with Peltier, Joule and Fourier heat conduction effects have been investigated using exergy analysis. New expressions for the interstage temperature, optimum current for the maximum cooling power, energy and exergy efficiency conditions, energy efficiency and exergy efficiency of a TTEC are derived as well. The number of thermocouples in the first and second stages of a TTEC for the maximum cooling power, energy and exergy efficiency conditions are optimized. The results show that the exergy efficiency is lower than the energy efficiency e.g., in an irreversible TTEC with total 30 thermocouples, heat sink temperature (TH) of 300 K and heat source temperature (TC) of 280 K, the obtained maximum cooling power, maximum energy and exergy efficiency are 20.37 W, 0.7147 and 5.10% respectively. It has been found that the Thomson effect increases the cooling power and energy efficiency of the TTEC system e.g., in the exoreversible TTEC the cooling power and energy efficiency increased from 14.87 W to 16.36 W and from 0.4079 to 0.4998 respectively for ΔTC of 40 K when Thomson effect is considered. It has also been found that the heat transfer area at the hot side of an irreversible TTEC should be higher than the cold side for maximum performance operation. This study will help in the designing of the actual multistage thermoelectric cooling systems.

  1. Validation of the Thomson, Perry and Miller (2007 Collaboration Instrument in the South African context

    Directory of Open Access Journals (Sweden)

    Debbie Roberts

    2017-02-01

    Full Text Available Orientation: Collaboration is deemed important in today’s connected and complex business environment. People’s ability to collaborate with each other in organisations is becoming a business imperative. This study focuses on a valid measurement of collaboration within organisations. Research purpose: Thomson, Perry and Miller (2007 developed a collaboration measurement instrument in the United States. The aim of this study was to validate this instrument for a South African context. Motivation for the study: South African organisations face unique challenges that require optimal use of resources to improve business results. Effective collaboration is considered a powerful strategy to achieve this. Measuring the extent of collaboration can help to identify required changes in business practices. As far as could be established, there is no evidence of collaboration instruments developed and validated in South Africa. Research design, approach and method: Additional items were designed for further development of the Thomson, Perry and Miller (2007 Collaboration Instrument sub-scales, as suggested by the authors. The revised questionnaire consisting of 31 (17 existing, 14 new items was distributed electronically to 4200 employees in two organisations, with 343 valid responses received. Reliability and construct validity were tested, as was convergent validity of the norms factor with the Trust in Teams Scale. Main findings: The results of the study support a four-factor, 29-item model of collaboration when applied to a South African sample. Cronbach’s alpha ranged between 0.85 and 0.95. Confirmatory Factor Analysis fits were at an acceptable level. Convergent validity showed a moderate fit with the data. Practical/managerial implications: South African managers and human resources practitioners can utilise results to foster a collaborative environment. Contribution/value-add: This study builds on the theoretical concept of collaboration as

  2. Validation of the Thomson, Perry and Miller (2007 Collaboration Instrument in the South African context

    Directory of Open Access Journals (Sweden)

    Debbie Roberts

    2017-01-01

    Full Text Available Orientation: Collaboration is deemed important in today’s connected and complex business environment. People’s ability to collaborate with each other in organisations is becoming a business imperative. This study focuses on a valid measurement of collaboration within organisations.Research purpose: Thomson, Perry and Miller (2007 developed a collaboration measurement instrument in the United States. The aim of this study was to validate this instrument for a South African context.Motivation for the study: South African organisations face unique challenges that require optimal use of resources to improve business results. Effective collaboration is considered a powerful strategy to achieve this. Measuring the extent of collaboration can help to identify required changes in business practices. As far as could be established, there is no evidence of collaboration instruments developed and validated in South Africa.Research design, approach and method: Additional items were designed for further development of the Thomson, Perry and Miller (2007 Collaboration Instrument sub-scales, as suggested by the authors. The revised questionnaire consisting of 31 (17 existing, 14 new items was distributed electronically to 4200 employees in two organisations, with 343 valid responses received. Reliability and construct validity were tested, as was convergent validity of the norms factor with the Trust in Teams Scale.Main findings: The results of the study support a four-factor, 29-item model of collaboration when applied to a South African sample. Cronbach’s alpha ranged between 0.85 and 0.95. Confirmatory Factor Analysis fits were at an acceptable level. Convergent validity showed a moderate fit with the data.Practical/managerial implications: South African managers and human resources practitioners can utilise results to foster a collaborative environment.Contribution/value-add: This study builds on the theoretical concept of collaboration as defined by

  3. Observation of Nonlinear Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kotseroglou, T.

    2003-12-19

    This experiment tests Quantum Electrodynamics in the strong field regime. Nonlinear Compton scattering has been observed during the interaction of a 46.6 GeV electron beam with a 10{sup 18} W/cm{sup 2} laser beam. The strength of the field achieved was measured by the parameter {eta} = e{var_epsilon}{sub rms}/{omega}mc = 0.6. Data were collected with infrared and green laser photons and circularly polarized laser light. The timing stabilization achieved between the picosecond laser and electron pulses has {sigma}{sub rms} = 2 ps. A strong signal of electrons that absorbed up to 4 infrared photons (or up to 3 green photons) at the same point in space and time, while emitting a single gamma ray, was observed. The energy spectra of the scattered electrons and the nonlinear dependence of the electron yield on the field strength agreed with the simulation over 3 orders of magnitude. The detector could not resolve the nonlinear Compton scattering from the multiple single Compton scattering which produced rates of scattered electrons of the same order of magnitude. Nevertheless, a simulation has studied this difference and concluded that the scattered electron rates observed could not be accounted for only by multiple ordinary Compton scattering; nonlinear Compton scattering processes are dominant for n {ge} 3.

  4. Scattering theory

    International Nuclear Information System (INIS)

    Friedrich, Harald

    2013-01-01

    Written by the author of the widely acclaimed textbook. Theoretical Atomic Physics Includes sections on quantum reflection, tunable Feshbach resonances and Efimov states. Useful for advanced students and researchers. This book presents a concise and modern coverage of scattering theory. It is motivated by the fact that experimental advances have shifted and broadened the scope of applications where concepts from scattering theory are used, e.g. to the field of ultracold atoms and molecules, which has been experiencing enormous growth in recent years, largely triggered by the successful realization of Bose-Einstein condensates of dilute atomic gases in 1995. In the present treatment, special attention is given to the role played by the long-range behaviour of the projectile-target interaction, and a theory is developed, which is well suited to describe near-threshold bound and continuum states in realistic binary systems such as diatomic molecules or molecular ions. The level of abstraction is kept as low as at all possible, and deeper questions related to mathematical foundations of scattering theory are passed by. The book should be understandable for anyone with a basic knowledge of nonrelativistic quantum mechanics. It is intended for advanced students and researchers, and it is hoped that it will be useful for theorists and experimentalists alike.

  5. Scattering theory

    CERN Document Server

    Friedrich, Harald

    2016-01-01

    This corrected and updated second edition of "Scattering Theory" presents a concise and modern coverage of the subject. In the present treatment, special attention is given to the role played by the long-range behaviour of the projectile-target interaction, and a theory is developed, which is well suited to describe near-threshold bound and continuum states in realistic binary systems such as diatomic molecules or molecular ions. It is motivated by the fact that experimental advances have shifted and broadened the scope of applications where concepts from scattering theory are used, e.g. to the field of ultracold atoms and molecules, which has been experiencing enormous growth in recent years, largely triggered by the successful realization of Bose-Einstein condensates of dilute atomic gases in 1995. The book contains sections on special topics such as near-threshold quantization, quantum reflection, Feshbach resonances and the quantum description of scattering in two dimensions. The level of abstraction is k...

  6. Neutron scattering

    International Nuclear Information System (INIS)

    1991-02-01

    The annual report on hand gives an overview of the research work carried out in the Laboratory for Neutron Scattering (LNS) of the ETH Zuerich in 1990. Using the method of neutron scattering, it is possible to examine in detail the static and dynamic properties of the condensed material. In accordance with the multidisciplined character of the method, the LNS has for years maintained a system of intensive co-operation with numerous institutes in the areas of biology, chemistry, solid-state physics, crystallography and materials research. In 1990 over 100 scientists from more than 40 research groups both at home and abroad took part in the experiments. It was again a pleasure to see the number of graduate students present, who were studying for a doctorate and who could be introduced into the neutron scattering during their stay at the LNS and thus were in the position to touch on central ways of looking at a problem in their dissertation using this modern experimental method of solid-state research. In addition to the numerous and interesting ways of formulating the questions to explain the structure, nowadays the scientific programme increasingly includes particularly topical studies in connection with high temperature-supraconductors and materials research

  7. Kirchhoff and thomson-tait transformations in the classical theory of plates

    Science.gov (United States)

    Vasil'ev, V. V.

    2012-09-01

    The transformation of the torque into the transverse force is considered; this transformation is traditional in the educational literature [1] and was proposed by Kirchhoff [2] and Thomson and Tait [3] to match the order of the differential equation of the classical theory of plates with the number of boundary conditions. It is shown that this transformation is not universal and its mathematical and physical justification depends on the conditions of the plate fixation and loading. It is shown that this justification is absent for the most widely used problems of bending of a rectangular plate freely supported and fixed on the contour.

  8. Design and Development of a Novel Knudsen Compressor as a Part of a Joule-Thomson Cryocooler

    Science.gov (United States)

    Muthuvijayan, Indra; Antelius, Mikael; Björneklett, Are; Nilsson, Peter; Thorslund, Robert

    2017-11-01

    This paper presents the design and development of a novel Knudsen compressor, with no moving parts, as a part of a Joule-Thomson cryocooler. The compressor works by using the Knudsen diffusion principle and includes a combination of graphene-based layers and Knudsen membranes in a particular fashion to pressurize the fluid. The Knudsen membrane for this application was selected by testing several commercially available materials. Prototypes of single stage and a multistage compressors are presented together with experimental evaluations. Insights on a Tube-in-Tube heat exchanger, as another part a the Joule-Thomson cryocooler, intended to integrate with the Knudsen compressor, are also presented.

  9. Deep inelastic scattering

    International Nuclear Information System (INIS)

    Zakharov, V.I.

    1977-01-01

    The present status of the quark-parton-gluon picture of deep inelastic scattering is reviewed. The general framework is mostly theoretical and covers investigations since 1970. Predictions of the parton model and of the asymptotically free field theories are compared with experimental data available. The valence quark approximation is concluded to be valid in most cases, but fails to account for the data on the total momentum transfer. On the basis of gluon corrections introduced to the parton model certain predictions concerning both the deep inelastic structure functions and form factors are made. The contributions of gluon exchanges and gluon bremsstrahlung are highlighted. Asymptotic freedom is concluded to be very attractive and provide qualitative explanation to some experimental observations (scaling violations, breaking of the Drell-Yan-West type relations). Lepton-nuclear scattering is pointed out to be helpful in probing the nature of nuclear forces and studying the space-time picture of the parton model

  10. Semiclassical scattering theory

    International Nuclear Information System (INIS)

    Di Salvo, A.

    1985-01-01

    It is intended to write the semiclassical scattering amplitude as a sum of terms, each of them being associated to trajectory. First of all the classical equations of motion are studied, considering both the analytical (real and complex) solutions and a certain type of singular solutions, which behave similary to the difracted rays in optics; in particular, in the case of a central nuclear potential, classical effects like rainbow and orbiting and also wave effects like diffraction and direct reflection are singled out. Successively, considering the Debye expansion of the scattering amplitude relative to a central nuclear potential, and evaluating asymptotically each term by means of the saddle point technique, the decay exponents and difraction coefficients relative to such a potential are determined

  11. HISTOPATHOLOGIC CHARACTERISTICS OF THYROID GLAND NEOPLASMS IN THOMSON'S GAZELLES ( EUDORCUS THOMSONII).

    Science.gov (United States)

    French, Stephanie J; Garner, Michael M; Kiupel, Matti

    2018-03-01

    Published reports of neoplasms in Thomson's gazelles ( Eudorcas thomsonii) are very rare, but thyroid tumors were the most common neoplasm of this species, accounting for 12% of reported pathologies in a 1998-2012 retrospective study of cases submitted for histologic review of grossly enlarged thyroid glands. This report describes the histological and immunohistochemical characteristics of thyroid neoplasms in 10 Thomson's gazelles from five different zoological collections. Neoplasms were submitted as biopsies from six gazelles or collected during necropsy from four gazelles. The most common clinical findings included a palpable mass on the ventral neck and progressive weight loss. Radiographic mineral density was detected in one of the neoplastic masses. Histologically, the neoplasms were classified as microfollicular thyroid adenoma ( n = 2), solid thyroid adenoma ( n = 2), papillary thyroid adenoma ( n = 1), and solid thyroid carcinoma ( n = 5). Neoplastic cells in all 10 neoplasms were positive for thyroid transcription factor 1 and thyroglobulin, but negative for calcitonin. While five cases had histologic features of malignancy, there was no evidence of metastatic disease either clinically (biopsies) or on necropsy. Numerous concurrent diseases, including cardiomyopathies and nephropathies, were present and led to choice for euthanasia in several cases.

  12. Gibbs–Thomson Effect in Planar Nanowires: Orientation and Doping Modulated Growth

    KAUST Repository

    Shen, Youde

    2016-06-02

    Epitaxy-enabled bottom-up synthesis of self-assembled planar nanowires via the vapor-liquid-solid mechanism is an emerging and promising approach toward large-scale direct integration of nanowire-based devices without postgrowth alignment. Here, by examining large assemblies of indium tin oxide nanowires on yttria-stabilized zirconia substrate, we demonstrate for the first time that the growth dynamics of planar nanowires follows a modified version of the Gibbs-Thomson mechanism, which has been known for the past decades to govern the correlations between thermodynamic supersaturation, growth speed, and nanowire morphology. Furthermore, the substrate orientation strongly influences the growth characteristics of epitaxial planar nanowires as opposed to impact at only the initial nucleation stage in the growth of vertical nanowires. The rich nanowire morphology can be described by a surface-energy-dependent growth model within the Gibbs-Thomson framework, which is further modulated by the tin doping concentration. Our experiments also reveal that the cutoff nanowire diameter depends on the substrate orientation and decreases with increasing tin doping concentration. These results enable a deeper understanding and control over the growth of planar nanowires, and the insights will help advance the fabrication of self-assembled nanowire devices. © 2016 American Chemical Society.

  13. The multiple-scattering series in few-nucleon systems

    Directory of Open Access Journals (Sweden)

    Baru V.

    2014-06-01

    Full Text Available We discuss under which circumstances the resummation of the multiple-scattering series is justified from an EFT point of view. The application to πd and K̅d scattering is briefly discussed.

  14. 77 FR 44221 - Notice of Availability of the Final Environmental Impact Statement for the Proposed Point Thomson...

    Science.gov (United States)

    2012-07-27

    ... evaluated reasonable alternative designs and potential impacts to the environment. The proposed project includes the construction of structures in navigable waters of the United States (U.S.) and the discharge of dredged and/or fill materials into waters of the U.S., including wetlands. The proposed work...

  15. 76 FR 70979 - Notice of Availability of the Draft Environmental Impact Statement for the Proposed Point Thomson...

    Science.gov (United States)

    2011-11-16

    ... Act (RHA) of 1899 and Section 404 of the Clean Water Act (CWA). The Draft EIS will be used to evaluate.... Authorities: Section 404 of the Clean Water Act (33 U.S.C. 1344) and Section 10 of the Rivers and Harbors Act... DEPARTMENT OF DEFENSE Department of the Army, U.S. Army Corps of Engineers Notice of Availability...

  16. Interference characterisation of a commercial Joule-Thomson cooler to be used in a SQUID-based heart monitor

    NARCIS (Netherlands)

    Bangma, M.R.; Bangma, M.R.; Rijpma, A.P.; de Vries, E.; Reincke, H.A.; Holland, Herman J.; ter Brake, Hermanus J.M.; Rogalla, Horst

    2001-01-01

    At the University of Twente, a foetal heart monitor based on a high-TC SQUID magnetometer system is under development. The purpose of this system is to measure a foetal heart signal in a clinical environment. For cooling a first demonstrator version, a closed-cycle Joule–Thomson cooler from APD

  17. Mida kujutab endast IB õppekava? / Toomas Kruusimägi, Anu Parts, Karl Hendrik Thomson ; intervjueerinud Raivo Juurak

    Index Scriptorium Estoniae

    Kruusimägi, Toomas, 1962-

    2010-01-01

    Uuest rahvusvahelisest International Baccalaureate'i (IB) õppekavast ja selle rakendamisest Tallinna Inglise Kolledži 11. klassis alates möödunud aastast räägivad kooli direktor Toomas Kruusimägi, õppedirektor Anu Parts ning õpilane Karl Hendrik Thomson

  18. Neutron scattering. Lectures

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2012-07-01

    The following topics are dealt with: Neutron scattering in contemporary research, neutron sources, symmetry of crystals, diffraction, nanostructures investigated by small-angle neutron scattering, the structure of macromolecules, spin dependent and magnetic scattering, structural analysis, neutron reflectometry, magnetic nanostructures, inelastic scattering, strongly correlated electrons, dynamics of macromolecules, applications of neutron scattering. (HSI)

  19. Neutron scattering. Lectures

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2012-01-01

    The following topics are dealt with: Neutron scattering in contemporary research, neutron sources, symmetry of crystals, diffraction, nanostructures investigated by small-angle neutron scattering, the structure of macromolecules, spin dependent and magnetic scattering, structural analysis, neutron reflectometry, magnetic nanostructures, inelastic scattering, strongly correlated electrons, dynamics of macromolecules, applications of neutron scattering. (HSI)

  20. Pauli Principle and Pion Scattering

    Science.gov (United States)

    Bethe, H. A.

    1972-10-01

    It is pointed out that if the Pauli principle is taken into account in the discussion of pion scattering by complex nuclei (as it ought, of course, to be) some rather implausible consequences of some earlier treatments of this problem can be avoided. (auth)

  1. Molecular phylogeny of equine herpesvirus 1 isolates from onager, zebra and Thomson's gazelle.

    Science.gov (United States)

    Ghanem, Y M; Fukushi, H; Ibrahim, E S M; Ohya, K; Yamaguchi, T; Kennedy, M

    2008-01-01

    Viruses related to equine herpesvirus type 1 (EHV-1) were isolated from an aborted fetus of an onager (Equus hemionus) in 1984, an aborted fetus of Grevy's zebra (Equus grevyi) in 1984 and a Thomson's gazelle (Gazella thomsoni) with nonsuppurative encephalitis in 1996, all in the USA. The mother of the onager fetus and the gazelle were kept near plains zebras (Equus burchelli). In phylogenetic trees based on the nucleotide sequences of the genes for glycoproteins B (gB), I (gI), and E (gE), and teguments including ORF8 (UL51), ORF15 (UL45), and ORF68 (US2), the onager, Grevy's zebra and gazelle isolates formed a genetic group that was different from several horse EHV-1 isolates. Within this group, the onager and gazelle isolates were closely related, while the Grevy's zebra isolate was distantly related to these two isolates. The epizootiological origin of the viruses is discussed.

  2. Study of Number of Nitrogen Fertigations on Improvement of Quantity and Quality of Thomson Navel Orange

    Directory of Open Access Journals (Sweden)

    H. Ebadi

    2012-12-01

    Full Text Available To compare the effects of various nitrogen (N fertigation frequencies on yield and fruit quality of Thomson navel orange, a field study was carried out in a randomized complete blocks design with five treatments and four replications during three years. Treatments included a subsoil N fertilizer placement (with drip irrigation and four N fertigation frequencies (2, 4, 6 and 8 applications per growing season. Results of soil and leaf analysis were used to determine the annul amount of applied fertilizers. In subsoil placement treatment, urea was applied two times (second half of March and second half of May and other fertilizers were applied only in March. In fertigation treatments, urea was applied by fertilizer tank in four frequencies, and other fertilizers were applied only in March. For all treatments, the amount and scheduling of irrigation was the same. The measured traits were total fruits weight (yield, single fruit weight, peel thickness, fruit diameter and length, acidity (TA and total soluble solids (TSS of the fruits. Analysis of the means showed that the yields of 6 and 8 fertigations were 5.6 to 32.1 percent more than the other treatments. But the yield of 8 applications per growing season differed significantly from 2 and 4 applications. Fruit weight and peel thickness of the treatments were not significantly different. Fruit diameter of 6-fertigation treatment was more than the other treatments, and had significant difference with 2-fertigation treatment. Significant difference between fruit juice quality of subsoil placement and fertigation treatments was not observed. But some differences were observed between fertigation treatments. In conclusion, for Thomson navel orange on the regions where similar to this research place, it can be suggested 6 applications of N fertigation.

  3. Tracking the density evolution in counter-propagating shock waves using imaging X-ray scattering

    Czech Academy of Sciences Publication Activity Database

    Zastrau, U.; Gamboa, E. J.; Kraus, D.; Benage, J. F.; Drake, R. P.; Efthimion, P.; Falk, Kateřina; Falcone, R.W.; Fletcher, L. B.; Galtier, E.; Gauthier, M.; Granados, E.; Hastings, J.B.; Heimann, P.; Hill, K.; Keiter, P. A.; Lu, J.; MacDonald, M. J.; Montgomery, D. S.; Nagler, B.; Pablant, N.; Schropp, A.; Tobias, B.; Gericke, D.O.; Glenzer, S. H.; Lee, H. J.

    2016-01-01

    Roč. 109, č. 3 (2016), 1-4, č. článku 031108. ISSN 0003-6951 R&D Projects: GA MŠk LQ1606; GA MŠk EF15_008/0000162 Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : Thomson scattering * metal transition * compression * deuterium * diamond * carbon * matter Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.411, year: 2016

  4. Diffusion equation representation of multiple-scatter gamma ray flux for 59.5, 122.1 and 279.2 keV point sources through water and graphite media

    International Nuclear Information System (INIS)

    Swarup, J.; Peshori, L.H.

    1986-01-01

    The transmitted γ fluxes for three sources, namely, 241 Am, 57 Co and 203 Hg, for the total spectrum as well as for the multiple-scatter peak, for different thicknesses of the water and graphite media have been represented by the diffusion formula, I=S/(4πDx esup(kx)), and compared with the earlier representation, I=I 0 esup(-ax). It is found that both the representations are equally good for the medium thicknesses taken in these measurements. (author)

  5. Bidirectional optical scattering facility

    Data.gov (United States)

    Federal Laboratory Consortium — Goniometric optical scatter instrument (GOSI)The bidirectional reflectance distribution function (BRDF) quantifies the angular distribution of light scattered from a...

  6. Elastic scattering at the LHC

    CERN Document Server

    Kaspar, Jan; Deile, M

    The seemingly simple elastic scattering of protons still presents a challenge for the theory. In this thesis we discuss the elastic scattering from theoretical as well as experimental point of view. In the theory part, we present several models and their predictions for the LHC. We also discuss the Coulomb-hadronic interference, where we present a new eikonal calculation to all orders of alpha, the fine-structure constant. In the experimental part we introduce the TOTEM experiment which is dedicated, among other subjects, to the measurement of the elastic scattering at the LHC. This measurement is performed primarily with the Roman Pot (RP) detectors - movable beam-pipe insertions hundreds of meters from the interaction point, that can detect protons scattered to very small angles. We discuss some aspects of the RP simulation and reconstruction software. A central point is devoted to the techniques of RP alignment - determining the RP sensor positions relative to each other and to the beam. At the end we pres...

  7. Anomalous inelastic neutron scattering from calcite

    International Nuclear Information System (INIS)

    Dove, M.T.; Harris, M.J.; Winkler, B.; Hagen, M.E.; Keele Univ.; Powell, B.M.; Steigenberger, U.

    1992-01-01

    Inelastic neutron scattering measurements on calcite (CaCO 3 ) in its low temperature phase have revealed the existence of an unusual column of inelastic scattering at the wavevector corresponding to the F point of the high temperature Brillouin zone. At the same wavevector there is also a transverse acoustic soft mode and the column of scattering ranges in energy from zero up to the soft mode. The intensity of the anomalous scattering increases rapidly with temperature, and is consistent with an Arrhenius relation of the form exp(-T * /T), where T * = 1035 K. We speculate that this scattering arises from thermal fluctuations of the calcite structure into a different ordered structure, which is related to an ordering instability at the F point. Evidence for this possibility has also been obtained from lattice energy calculations. (author)

  8. Classical trajectory in non-relativistic scattering

    International Nuclear Information System (INIS)

    Williams, A.C.

    1978-01-01

    With the statistical interpretation of quantum mechanics as a guide, the classical trajectory is incorporated into quantum scattering theory. The Feynman path integral formalism is used as a starting point, and classical transformation theory is applied to the phase of the wave function so derived. This approach is then used to derive an expression for the scattering amplitude for potential scattering. It is found that the amplitude can be expressed in an impact parameter representation similar to the Glauber formalism. Connections are then made to the Glauber approximation and to semiclassical approximations derived from the Feynman path integral formalism. In extending this analysis to projectile-nucleus scattering, an approximation scheme is given with the first term being the same as in Glauber's multiple scattering theory. Higher-order approximations, thus, are found to give corrections to the fixed scatterer form of the impulse approximation inherent in the Glauber theory

  9. Smoke filtration in the glass industry. Thomson Videoglass` global approach with closed loop recycling; Fitration des fumees dans l`industrie du verre. L`approche globale avec recyclage en boucle fermee de thomson videoglass

    Energy Technology Data Exchange (ETDEWEB)

    Mocek, L. [Thomson Videoglass, 77 - Bagneaux-sur-Loing (France)

    1996-12-31

    Thomson Videoglass, an ISO 9002 certified manufacturer of glass components for Tv sets in France, has introduced a global closed-loop recycling dust filtration system for glass kilns; electrostatic filters and bag filters (for the lead-containing flat glass kiln) have been selected and collected dusts are recycled in the cone glass kiln. Energy savings, operating conditions, investment and operating costs are discussed together with filter corrosion, clogging-up and service life issues and dust extraction performances

  10. Tipping Point

    Medline Plus

    Full Text Available ... en español Blog About OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by ... danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe ...

  11. Estimation of Freezing Point of Hydrocarbon and Hydrofluorocarbon Mixtures for Mixed Refrigerant jt Cryocooler

    Science.gov (United States)

    Hwang, G.; Lee, J.; Jeong, S.

    2010-04-01

    Estimating the freezing point of refrigerant is an essential part in designing an MR JT (Mixed refrigerant Joule-Thomson) cryocooler to prevent itself from clogging and to operate with stability. There were researches on estimating freezing point, but some of them resulted in the wrong prediction of clogging. In this paper, the freezing point of the MR is precisely estimated with caution of clogging. The solubility of HC (hydrocarbon) and HFC (hydrofluorocarbon) mixture components are obtained with their activity coefficients, which represent the molecular interaction among the components. The freezing points of the MR JT cryocooler are systematically investigated in the operating temperature range from 70 K to 90 K.

  12. Neutron scattering. Lectures

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2010-07-01

    The following topics are dealt with: Neutron sources, symmetry of crystals, diffraction, nanostructures investigated by small-angle neutron scattering, the structure of macromolecules, spin dependent and magnetic scattering, structural analysis, neutron reflectometry, magnetic nanostructures, inelastic scattering, strongly correlated electrons, dynamics of macromolecules, applications of neutron scattering. (HSI)

  13. Neutron scattering. Lectures

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2013-07-01

    The following topics are dealt with: Neutron sources, symmetry of crystals, nanostructures investigated by small-angle neutron scattering, structure of macromolecules, spin dependent and magnetic scattering, structural analysis, neutron reflectometry, magnetic nanostructures, inelastic neutron scattering, strongly correlated electrons, polymer dynamics, applications of neutron scattering. (HSI)

  14. Neutron scattering. Lectures

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2010-01-01

    The following topics are dealt with: Neutron sources, symmetry of crystals, diffraction, nanostructures investigated by small-angle neutron scattering, the structure of macromolecules, spin dependent and magnetic scattering, structural analysis, neutron reflectometry, magnetic nanostructures, inelastic scattering, strongly correlated electrons, dynamics of macromolecules, applications of neutron scattering. (HSI)

  15. Neutron scattering. Lectures

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2013-01-01

    The following topics are dealt with: Neutron sources, symmetry of crystals, nanostructures investigated by small-angle neutron scattering, structure of macromolecules, spin dependent and magnetic scattering, structural analysis, neutron reflectometry, magnetic nanostructures, inelastic neutron scattering, strongly correlated electrons, polymer dynamics, applications of neutron scattering. (HSI)

  16. Outline of Neutron Scattering Formalism

    OpenAIRE

    Berk, N. F.

    1993-01-01

    Neutron scattering formalism is briefly surveyed. Topics touched upon include coherent and incoherent scattering, bound and free cross-sections, the Van Hove formalism, magnetic scattering, elastic scattering, the static approximation, sum rules, small angle scattering, inelastic scattering, thermal diffuse scattering, quasielastic scattering, and neutron optics.

  17. Kerr scattering coefficients via isomonodromy

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Bruno Carneiro da [Departamento de Física, Universidade Federal de Pernambuco,50670-901, Recife, Pernambuco (Brazil); Novaes, Fábio [International Institute of Physics, Federal University of Rio Grande do Norte,Av. Odilon Gomes de Lima 1722, Capim Macio, Natal-RN 59078-400 (Brazil)

    2015-11-23

    We study the scattering of a massless scalar field in a generic Kerr background. Using a particular gauge choice based on the current conservation of the radial equation, we give a generic formula for the scattering coefficient in terms of the composite monodromy parameter σ between the inner and the outer horizons. Using the isomonodromy flow, we calculate σ exactly in terms of the Painlevé V τ-function. We also show that the eigenvalue problem for the angular equation (spheroidal harmonics) can be calculated using the same techniques. We use recent developments relating the Painlevé V τ-function to Liouville irregular conformal blocks to claim that this scattering problem is solved in the combinatorial sense, with known expressions for the τ-function near the critical points.

  18. Helium atom scattering from surfaces

    CERN Document Server

    1992-01-01

    High resolution helium atom scattering can be applied to study a number of interesting properties of solid surfaces with great sensitivity and accuracy. This book treats in detail experimental and theoretical aspects ofthis method as well as all current applications in surface science. The individual chapters - all written by experts in the field - are devoted to the investigation of surface structure, defect shapes and concentrations, the interaction potential, collective and localized surface vibrations at low energies, phase transitions and surface diffusion. Over the past decade helium atom scattering has gained widespread recognitionwithin the surface science community. Points in its favour are comprehensiveunderstanding of the scattering theory and the availability of well-tested approximation to the rigorous theory. This book will be invaluable to surface scientists wishing to make an informed judgement on the actual and potential capabilities of this technique and its results.

  19. An Encyclopedia of the History of Classical Archaeology, edited by Nancy Thomson de Grummond, Green­wood Press

    Directory of Open Access Journals (Sweden)

    Douglas R. Givens

    1997-05-01

    Full Text Available Nancy Thomson de Grummond has done a tremendous service for those scholars interested in the history of Classical Archaeology. In the 1330 pages that are the two handsome volumes that makeup the set, Thomson de Grummond provides a series of biographical sketches a many classical archaeologists and discussions of archaeological site locations which provide an excellent and concise look at the conduct of classical archae­ology through time. The biographical sketches contained in the volumes represent both the lay and profes­sional classical archaeologist. Represented in the volumes are archaeologists from established religious orders in the classical world as well as those who derived their interest in classical archaeology from the burgeoning interest in the development of the European scientific community. In addition, discussion of selected artifact discoveries are included in both volumes to round out the interest that anyone might have in the origins and development of classical archaeology.

  20. Neutron scattering. Lectures

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2010-07-01

    The following topics are dealt with: Neutron sources, neutron properties and elastic scattering, correlation functions measured by scattering experiments, symmetry of crystals, applications of neutron scattering, polarized-neutron scattering and polarization analysis, structural analysis, magnetic and lattice excitation studied by inelastic neutron scattering, macromolecules and self-assembly, dynamics of macromolecules, correlated electrons in complex transition-metal oxides, surfaces, interfaces, and thin films investigated by neutron reflectometry, nanomagnetism. (HSI)

  1. Neutron scattering. Lectures

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2010-01-01

    The following topics are dealt with: Neutron sources, neutron properties and elastic scattering, correlation functions measured by scattering experiments, symmetry of crystals, applications of neutron scattering, polarized-neutron scattering and polarization analysis, structural analysis, magnetic and lattice excitation studied by inelastic neutron scattering, macromolecules and self-assembly, dynamics of macromolecules, correlated electrons in complex transition-metal oxides, surfaces, interfaces, and thin films investigated by neutron reflectometry, nanomagnetism. (HSI)

  2. A spectral geometric model for Compton single scatter in PET based on the single scatter simulation approximation

    DEFF Research Database (Denmark)

    Kazantsev, I.G.; Olsen, Ulrik Lund; Poulsen, Henning Friis

    2018-01-01

    scatter is interpreted as the volume integral over scatter points that constitute a rotation body with a football shape, while single scattering with a certain angle is evaluated as the surface integral over the boundary of the rotation body. The equations for total and sample single scatter calculations...... are derived using a single scatter simulation approximation. We show that the three-dimensional slice-by-slice filtered backprojection algorithm is applicable for scatter data inversion provided that the attenuation map is assumed to be constant. The results of the numerical experiments are presented....

  3. Observation of the ion-acoustic feature in the spectrum of far-infrared radiation scattered from a He-plasma in a tokamak

    International Nuclear Information System (INIS)

    Salito, S.A.; Siegrist, M.R.; Behn, R.; Dicken, D.; Hackmann, J.

    1989-01-01

    The ion-acoustic feature in the spectrum of a He plasma produced in a tokamak has been observed by collective Thomson scattering of far-infrared radiation. The spectral distribution and the intensity of the scattered radiation correspond to density fluctuations at the thermal level. Since the resonant feature is very sensitive to the ratio T e /T i , good precision of a T i measurement can be obtained when T e is known. The results confirm the interpretation of earlier measurements in H and D plasmas. (author) 4 figs., 1 tab., 3 refs

  4. Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging plate detectors for protons, deuterons, and alpha particles.

    Science.gov (United States)

    Freeman, C G; Fiksel, G; Stoeckl, C; Sinenian, N; Canfield, M J; Graeper, G B; Lombardo, A T; Stillman, C R; Padalino, S J; Mileham, C; Sangster, T C; Frenje, J A

    2011-07-01

    A Thomson parabola ion spectrometer has been designed for use at the Multiterawatt (MTW) laser facility at the Laboratory for Laser Energetics (LLE) at the University of Rochester. This device uses parallel electric and magnetic fields to deflect particles of a given mass-to-charge ratio onto parabolic curves on the detector plane. Once calibrated, the position of the ions on the detector plane can be used to determine the particle energy. The position dispersion of both the electric and magnetic fields of the Thomson parabola was measured using monoenergetic proton and alpha particle beams from the SUNY Geneseo 1.7 MV tandem Pelletron accelerator. The sensitivity of Fujifilm BAS-TR imaging plates, used as a detector in the Thomson parabola, was also measured as a function of the incident particle energy over the range from 0.6 MeV to 3.4 MeV for protons and deuterons and from 0.9 MeV to 5.4 MeV for alpha particles. The device was used to measure the energy spectrum of laser-produced protons at MTW.

  5. Scattering Solar Thermal Concentrators

    Energy Technology Data Exchange (ETDEWEB)

    Giebink, Noel C. [Pennsylvania State Univ., State College, PA (United States)

    2015-01-31

    This program set out to explore a scattering-based approach to concentrate sunlight with the aim of improving collector field reliability and of eliminating wind loading and gross mechanical movement through the use of a stationary collection optic. The approach is based on scattering sunlight from the focal point of a fixed collection optic into the confined modes of a sliding planar waveguide, where it is transported to stationary tubular heat transfer elements located at the edges. Optical design for the first stage of solar concentration, which entails focusing sunlight within a plane over a wide range of incidence angles (>120 degree full field of view) at fixed tilt, led to the development of a new, folded-path collection optic that dramatically out-performs the current state-of-the-art in scattering concentration. Rigorous optical simulation and experimental testing of this collection optic have validated its performance. In the course of this work, we also identified an opportunity for concentrating photovoltaics involving the use of high efficiency microcells made in collaboration with partners at the University of Illinois. This opportunity exploited the same collection optic design as used for the scattering solar thermal concentrator and was therefore pursued in parallel. This system was experimentally demonstrated to achieve >200x optical concentration with >70% optical efficiency over a full day by tracking with <1 cm of lateral movement at fixed latitude tilt. The entire scattering concentrator waveguide optical system has been simulated, tested, and assembled at small scale to verify ray tracing models. These models were subsequently used to predict the full system optical performance at larger, deployment scale ranging up to >1 meter aperture width. Simulations at an aperture widths less than approximately 0.5 m with geometric gains ~100x predict an overall optical efficiency in the range 60-70% for angles up to 50 degrees from normal. However, the

  6. Thomson Parabola Spectrometer for Energetic Ions Emitted from Sub-ns Laser Generated Plasmas

    Directory of Open Access Journals (Sweden)

    Mariapompea Cutroneo

    2013-01-01

    Full Text Available Laser-generated plasmas were obtained in high vacuum by irradiating micrometric thin films (Au, Au/Mylar, Mylar with the Asterix laser at the PALS Research Infrastructure in Prague. Irradiations at the fundamental wavelength, 300 ps pulse duration, at intensities up to about 1016W/cm2, enabled ions to be accelerated in forward direction with kinetic energies of the order of 2 MeV/charge state. Protons above 2 MeV were obtained in the direction orthogonal to the target surface in selffocusing conditions. Gold ions up to about 120 MeV and 60+ charge state were detected. Ion collectors and semiconductor SiC detectors were employed in time-of-flight arrangement in order to measure the ion velocities as a function of the angle around the normal direction to the target surface. A Thomson parabola spectrometer (TPS with a multi-channel-plate detector was used to separate the different ion contributions to the charge emission in single laser shots, and to get information on the ion charge states, energy and proton acceleration. TPS experimental spectra were compared with accurate TOSCA simulations of TPS parabolas.

  7. Calibration of a Thomson parabola ion spectrometer using proton beams from a pelletron accelerator

    Science.gov (United States)

    Canfield, Michael; Lombardo, Andrew; Graeper, Gavin; Stillman, Collin; Freeman, Charles; Fiksel, Gennady; Stoeckl, Christian; Sinenian, Nareg

    2010-11-01

    The position-to-energy calibration of a Thomson parabola ion spectrometer (TPIS) was measured using proton beams from the 1.7 MV tandem pelletron accelerator at SUNY Geneseo. The TPIS was designed for use on the multiterawatt (MTW) laser facility at the Laboratory for Laser Energetics (LLE). The TPIS implements parallel electric and magnetic fields to separate ions of a given mass-to-charge ratio onto parabolic curves on the detector plane. The position of the ions along the parabola is used to determine the ions' energy. Monoenergetic proton beams with energies between approximately 1 and 3 MeV were directed into the TPIS. Both radiochromic film (RCF) and Fujifilm imaging plates (IP) were placed at the rear of the TPIS and were used to detect the protons. The horizontal deflection due to the electrostatic plates and the vertical deflection due to the permanent magnetic field were studied as a function of the proton energy. This research was funded in part by DOE.

  8. Investigation of pressure drop in capillary tube for mixed refrigerant Joule-Thomson cryocooler

    International Nuclear Information System (INIS)

    Ardhapurkar, P. M.; Sridharan, Arunkumar; Atrey, M. D.

    2014-01-01

    A capillary tube is commonly used in small capacity refrigeration and air-conditioning systems. It is also a preferred expansion device in mixed refrigerant Joule-Thomson (MR J-T) cryocoolers, since it is inexpensive and simple in configuration. However, the flow inside a capillary tube is complex, since flashing process that occurs in case of refrigeration and air-conditioning systems is metastable. A mixture of refrigerants such as nitrogen, methane, ethane, propane and iso-butane expands below its inversion temperature in the capillary tube of MR J-T cryocooler and reaches cryogenic temperature. The mass flow rate of refrigerant mixture circulating through capillary tube depends on the pressure difference across it. There are many empirical correlations which predict pressure drop across the capillary tube. However, they have not been tested for refrigerant mixtures and for operating conditions of the cryocooler. The present paper assesses the existing empirical correlations for predicting overall pressure drop across the capillary tube for the MR J-T cryocooler. The empirical correlations refer to homogeneous as well as separated flow models. Experiments are carried out to measure the overall pressure drop across the capillary tube for the cooler. Three different compositions of refrigerant mixture are used to study the pressure drop variations. The predicted overall pressure drop across the capillary tube is compared with the experimentally obtained value. The predictions obtained using homogeneous model show better match with the experimental results compared to separated flow models

  9. Tipping Point

    Medline Plus

    Full Text Available ... OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point ... 24 hours a day. For young children whose home is a playground, it’s the best way to ...

  10. Fixed Points

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 5. Fixed Points - From Russia with Love - A Primer of Fixed Point Theory. A K Vijaykumar. Book Review Volume 5 Issue 5 May 2000 pp 101-102. Fulltext. Click here to view fulltext PDF. Permanent link:

  11. Lévy based Cox point processes

    DEFF Research Database (Denmark)

    Hellmund, Gunnar; Prokesová, Michaela; Jensen, Eva Bjørn Vedel

    2008-01-01

    In this paper we introduce Lévy-driven Cox point processes (LCPs) as Cox point processes with driving intensity function Λ defined by a kernel smoothing of a Lévy basis (an independently scattered, infinitely divisible random measure). We also consider log Lévy-driven Cox point processes (LLCPs...

  12. Algebraic scattering theory and heavy ion scattering

    International Nuclear Information System (INIS)

    Allen, L.J.; Amos, K.; Berge, L.; Fiedeldey, H.

    1993-01-01

    Algebraic scattering theory is used to analyze elastic scattering cross-sections from heavy ion collisions. Collisions epitomized by strong absorption lead to algebraic potentials that can be described by simple exponential forms. But for collisions that are 'transparent', while asymptotically the algebraic potentials are exponential, their actual form (for low 1-values) is quite complex. 7 refs., 4 figs

  13. Delayed Union of a Jones Fracture in a Patient With Rothmund-Thomson Syndrome: A Case Report and Review of the Literature.

    Science.gov (United States)

    Barisonek, Kirsten L; Protzman, Nicole M; Wobst, Garrett M; Brigido, Stephen A

    2016-01-01

    Rothmund-Thomson syndrome is a rare autosomal recessive genodermatosis, characterized by poikiloderma, small stature, juvenile cataracts, sparse hair, skeletal abnormalities, and a predisposition to osteogenic sarcomas and skin cancers. Although numerous skeletal abnormalities have been described in patients with Rothmund-Thomson syndrome, to our knowledge, only 1 study has shown evidence of delayed fracture healing in a patient with Rothmund-Thomson syndrome. We present the case of a 13-year-old female diagnosed with Rothmund-Thomson syndrome who demonstrated delayed union of her fifth metatarsal after a Jones fracture. She was treated conservatively for 6 weeks with non-weightbearing cast immobilization and was then transitioned to a controlled ankle motion walker for an additional 4 weeks. Two months later, however, she continued to experience pain, and, on radiographic examination, the fracture remained unchanged. Therefore, with her guardian's consent, the patient elected to undergo open reduction and internal fixation of the fifth metatarsal fracture. At 8 weeks postoperatively, the patient reported a subsidence of symptoms and had returned to normal activity. With our report, we hope to increase practitioner awareness that delayed bone healing could be a possibility in patients with Rothmund-Thomson syndrome and encourage consideration of routine imaging and supplementation with calcium and vitamin D. Additionally, the present findings suggest that patients with Rothmund-Thomson syndrome could benefit from early surgical intervention, given their poor bone healing capacity and high likelihood of nonunion. Although the association between impaired bone healing and Rothmund-Thomson syndrome is rational, additional studies are needed to determine the prevalence of chronic nonunion in this patient population. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Neutron scattering from fractals

    DEFF Research Database (Denmark)

    Kjems, Jørgen; Freltoft, T.; Richter, D.

    1986-01-01

    The scattering formalism for fractal structures is presented. Volume fractals are exemplified by silica particle clusters formed either from colloidal suspensions or by flame hydrolysis. The determination of the fractional dimensionality through scattering experiments is reviewed, and recent small...

  15. Elastic magnetic electron scattering

    International Nuclear Information System (INIS)

    Sick, I.

    1985-01-01

    The paper surveys the field of elastic magnetic electron scattering. Magnetic scattering as a configuration analyzer; magnetic form factors of high multipole order; absolute spectroscopic factors; and non-nucleonic constituents; are all discussed. (U.K.)

  16. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... see news reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The ...

  17. Inverse Scattering in a Multipath Environment

    Directory of Open Access Journals (Sweden)

    A. Cuccaro

    2016-09-01

    Full Text Available In this contribution an inverse scattering problem is ad- dressed in a multipath environment. In particular, multipath is created by known ”extra” point-like scatterers (passive elements expressely deployed between the scene under in- vestigation and the source/measurement domains. Through a back-projection imaging scheme, the role of the passive elements on the achievable performance is shown and com- pared to the free-space case.

  18. Neutron scattering studies of solid electrolytes

    International Nuclear Information System (INIS)

    Shapiro, S.M.

    1976-01-01

    The role which neutron scattering can play in determining the nature of the disorder and the conducting mechanism in the solid electrolytes is discussed. First, some of the general formalism for elastic and inelastic neutron scattering is reviewed, and the quantities which can be measured are pointed out. Then the application of neutron scattering to the studies of three different problems is examined; the anion disorder in the fluorite system, the dynamical behavior in beta-alumina, and the cation diffusion in αAgI are discussed. 8 figures

  19. Light-scattering theory of diffraction.

    Science.gov (United States)

    Guo, Wei

    2010-03-01

    Since diffraction is a scattering process in principle, light propagation through one aperture in a screen is discussed in the light-scattering theory. Through specific calculation, the expression of the electric field observed at an observation point is obtained and is used not only to explain why Kirchhoff's diffraction theory is a good approximation when the screen is both opaque and sufficiently thin but also to demonstrate that the mathematical and physical problems faced by Kirchhoff's theory are avoided in the light-scattering theory.

  20. Electron scattering from tetrahydrofuran

    International Nuclear Information System (INIS)

    Fuss, M C; Sanz, A G; García, G; Muñoz, A; Oller, J C; Blanco, F; Do, T P T; Brunger, M J; Almeida, D; Limão-Vieira, P

    2012-01-01

    Electron scattering from Tetrahydrofuran (C 4 H 8 O) was investigated over a wide range of energies. Following a mixed experimental and theoretical approach, total scattering, elastic scattering and ionization cross sections as well as electron energy loss distributions were obtained.

  1. Scattering theory and orthogonal polynomials

    International Nuclear Information System (INIS)

    Geronimo, J.S.

    1977-01-01

    The application of the techniques of scattering theory to the study of polynomials orthogonal on the unit circle and a finite segment of the real line is considered. The starting point is the recurrence relations satisfied by the polynomials instead of the orthogonality condition. A set of two two terms recurrence relations for polynomials orthogonal on the real line is presented and used. These recurrence relations play roles analogous to those satisfied by polynomials orthogonal on unit circle. With these recurrence formulas a Wronskian theorem is proved and the Christoffel-Darboux formula is derived. In scattering theory a fundamental role is played by the Jost function. An analogy is deferred of this function and its analytic properties and the locations of its zeros investigated. The role of the analog Jost function in various properties of these orthogonal polynomials is investigated. The techniques of inverse scattering theory are also used. The discrete analogues of the Gelfand-Levitan and Marchenko equations are derived and solved. These techniques are used to calculate asymptotic formulas for the orthogonal polynomials. Finally Szego's theorem on toeplitz and Hankel determinants is proved using the recurrence formulas and some properties of the Jost function. The techniques of inverse scattering theory are used to calculate the correction terms

  2. A spectral geometric model for Compton single scatter in PET based on the single scatter simulation approximation

    Science.gov (United States)

    Kazantsev, I. G.; Olsen, U. L.; Poulsen, H. F.; Hansen, P. C.

    2018-02-01

    We investigate the idealized mathematical model of single scatter in PET for a detector system possessing excellent energy resolution. The model has the form of integral transforms estimating the distribution of photons undergoing a single Compton scattering with a certain angle. The total single scatter is interpreted as the volume integral over scatter points that constitute a rotation body with a football shape, while single scattering with a certain angle is evaluated as the surface integral over the boundary of the rotation body. The equations for total and sample single scatter calculations are derived using a single scatter simulation approximation. We show that the three-dimensional slice-by-slice filtered backprojection algorithm is applicable for scatter data inversion provided that the attenuation map is assumed to be constant. The results of the numerical experiments are presented.

  3. Periodic instantons and scattering amplitudes

    International Nuclear Information System (INIS)

    Khlebnikov, S.Yu.; Rubakov, V.A.; Tinyakov, P.G.

    1991-04-01

    We discuss the role of periodic euclidean solutions with two turning points and zero winding number (periodic instantons) in instanton induced processes below the sphaleron energy E sph . We find that the periodic instantons describe certain multiparticle scattering events leading to the transitions between topologically distinct vacua. Both the semiclassical amplitudes and inital and final states of these transitions are determined by the periodic instantons. Furthermore, the corresponding probabilities are maximal among all states of given energy. We show that at E ≤ E sph , the periodic instantons can be approximated by infinite chains of ordinary instantons and anti-instantons, and they naturally emerge as deformations of the zero energy instanton. In the framework of 2d abelian Higgs model and 4d electroweak theory we show, however, that there is not obvious relation between periodic instantons and two-particle scattering amplitudes. (orig.)

  4. Harmonic generation in laser-free electron scattering reconsidered

    International Nuclear Information System (INIS)

    Puntajer, A.K.; Leubner, C.

    1988-01-01

    For zero electron drift velocity, the corrected version of Vachaspati's classical cross sections deviates strongly from a semi-classical one by Ehlotzky and from an unpublished quantum electrodynamical cross section by Jafarpour. Therefore, the cross section is recalculated within classical electrodynamics, which suffices for the experimental configurations in question. This classical cross section, derivable more simply and with fewer approximations than the semi-classical one, nevertheless agrees perfectly with Elotzky's result for all harmonics, but only to some extend with Vachaspati's earlier version of the classical second harmonic cross section, and not at all with his corrected one, nor with Jafarpour's quantum electrodynamical one. Moreover, it also incorporates relativistic Thomson scattering as envisaged by McDonald. For second harmonic scattering, there is perfect agreement between the semi-classical cross section and the present classical one. Vachaspati's earlier version agrees to some extend, whereas his corrected one and Jafarpour's unpublished QED cross section deviate strongly. Even for zero electron drift velocity, the cross section exhibits a marked forward-backward asymmetry, briefly mentioned by Sarachik and Schappert. It can be explained as an interference between the fields produced by the linear and nonlinear components of the electron motion, and it renders Englert and Rinehart's direction of observation most unfavorable for observing second harmonic photons. 7 refs., 1 fig

  5. Micromachined Joule-Thomson coolers for cooling low-temperature detectors and electronics

    Science.gov (United States)

    ter Brake, Marcel; Lerou, P. P. P. M.; Burger, J. F.; Holland, H. J.; Derking, J. H.; Rogalla, H.

    2017-11-01

    The performance of electronic devices can often be improved by lowering the operating temperature resulting in lower noise and larger speed. Also, new phenomena can be applied at low temperatures, as for instance superconductivity. In order to fully exploit lowtemperature electronic devices, the cryogenic system (cooler plus interface) should be `invisible' to the user. It should be small, low-cost, low-interference, and above all very reliable (long-life). The realization of cryogenic systems fulfilling these requirements is the topic of research of the Cooling and Instrumentation group at the University of Twente. A MEMS-based cold stage was designed and prototypes were realized and tested. The cooler operates on basis of the Joule-Thomson effect. Here, a high-pressure gas expands adiabatically over a flow restriction and thus cools and liquefies. Heat from the environment (e.g., an optical detector) can be absorbed in the evaporation of the liquid. The evaporated working fluid returns to the low-pressure side of the system via a counter-flow heat exchanger. In passing this heat exchanger, it takes up heat from the incoming high-pressure gas that thus is precooled on its way to the restriction. The cold stage consists of a stack of three glass wafers. In the top wafer, a high-pressure channel is etched that ends in a flow restriction with a height of typically 300 nm. An evaporator volume crosses the center wafer into the bottom wafer. This bottom wafer contains the lowpressure channel thus forming a counter-flow heat exchanger. A design aiming at a net cooling power of 10 mW at 96 K and operating with nitrogen as the working fluid was optimized based on the minimization of entropy production. The optimum cold finger measures 28 mm x 2.2 mm x 0.8 mm operating with a nitrogen flow of 1 mg/s at a high pressure of 80 bar and a low pressure of 6 bar. The design and fabrication of the coolers will be discussed along with experimental results.

  6. Neutron scattering and physisorption

    International Nuclear Information System (INIS)

    Marlow, I.; Thomas, R.K.; Trewern, T.D.

    1977-01-01

    Neutron scattering experiments on methane and ammonia adsorbed on a graphitized carbon black are described. Diffraction from adsorbed deuterated methane shows that, at a coverage of 0.7, it forms an epitaxial layer with a √3x√3 structure. Between 50 and 60 K it undergoes a phase transition from two-dimensional solid to liquid (bulk melting point=89.7 K). Similar results are obtained for deuterated methane on a sample of graphon intercalated with potassium. From the effect of adsorbed methane on the intensities of 001 peaks of both substrates the carbon atom of the methane is estimated to be 3.3+-0.2 A from the surface. Ammonia-d 3 on graphon behaves quite differently from methane. It follows a type III isotherm and at low temperatures desorbs from the surface to form bulk ammonia. This has anomalous melting properties which are shown to be related to adsorption isobars for the system. The detailed interpretation of the results emphasizes the close link between adsorption and heterogeneous nucleation. Quasielastic experiments on the ammonia-graphon system show that the adsorbed ammonia is undergoing translational diffusion on the surface which is much faster than in the bulk. This is attributed to the breaking up of the hydrogen bonded network normally present in t

  7. Introduction to neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W.E. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-11-01

    We give here an introduction to the theoretical principles of neutron scattering. The relationship between scattering- and correlation-functions is particularly emphasized. Within the framework of linear response theory (justified by the weakness of the basic interaction) the relation between fluctuation and dissipation is discussed. This general framework explains the particular power of neutron scattering as an experimental method. (author) 4 figs., 4 refs.

  8. Dr John Thomson (1847-1909). Pioneer surgeon, military surgeon and a founder of St John Ambulance in Australia.

    Science.gov (United States)

    Pearn, J; Wales, M

    Surgeon John Thomson (1847-1909), a Scot who made his life's work in Queensland, was a pioneer surgeon, radiologist and bacteriologist, and one of the founders of the St John Ambulance movement in Australia and the Railway Ambulance Corps. He was variously President of the British Medical Association (Queensland Branch), the Medical Board of Queensland, the Medico-Ethical Association, and the Intercolonial Medical Congress, which was held in Brisbane in 1899. A pioneer military surgeon in this country, he was the foundation Principal Medical Officer (as Surgeon-Major) of the Queensland Ambulance Corps within the Queensland Defence Force. His advocacy for a university north of Sydney was one of the factors which led to the foundation of the University of Queensland, a body which honoured him by the establishment of the John Thomson Lectureship, which for half a century was its most prestigious public oration. The life and times of this singular doctor exemplify one small class of pre-Federation medical pioneers whose professional outreach established a number of voluntary organisations which have blossomed in Australian society to the present day.

  9. Acoustic scattering by multiple elliptical cylinders using collocation multipole method

    International Nuclear Information System (INIS)

    Lee, Wei-Ming

    2012-01-01

    This paper presents the collocation multipole method for the acoustic scattering induced by multiple elliptical cylinders subjected to an incident plane sound wave. To satisfy the Helmholtz equation in the elliptical coordinate system, the scattered acoustic field is formulated in terms of angular and radial Mathieu functions which also satisfy the radiation condition at infinity. The sound-soft or sound-hard boundary condition is satisfied by uniformly collocating points on the boundaries. For the sound-hard or Neumann conditions, the normal derivative of the acoustic pressure is determined by using the appropriate directional derivative without requiring the addition theorem of Mathieu functions. By truncating the multipole expansion, a finite linear algebraic system is derived and the scattered field can then be determined according to the given incident acoustic wave. Once the total field is calculated as the sum of the incident field and the scattered field, the near field acoustic pressure along the scatterers and the far field scattering pattern can be determined. For the acoustic scattering of one elliptical cylinder, the proposed results match well with the analytical solutions. The proposed scattered fields induced by two and three elliptical–cylindrical scatterers are critically compared with those provided by the boundary element method to validate the present method. Finally, the effects of the convexity of an elliptical scatterer, the separation between scatterers and the incident wave number and angle on the acoustic scattering are investigated.

  10. Quantum optics in multiple scattering random media

    DEFF Research Database (Denmark)

    Lodahl, Peter

    wave scattering has the potential of enhancing communication capacities, is ubiquitous in acoustical and biomedical imaging, and is the basis for fundamental findings such as intensity correlations, enhanced backscattering, and Anderson localization of light. Recently, theoretical work has considered......Quantum Optics in Multiple Scattering Random Media Peter Lodahl Research Center COM, Technical University of Denmark, Dk-2800 Lyngby, Denmark. Coherent transport of light in a disordered random medium has attracted enormous attention both from a fundamental and application point of view. Coherent...... quantum optics in multiple scattering media and novel fundamental phenomena have been predicted when examining quantum fluctuations instead of merely the intensity of the light [1]. Here I will present the first experimental study of the propagation of quantum noise through an elastic, multiple scattering...

  11. Elastic scattering phenomenology

    Energy Technology Data Exchange (ETDEWEB)

    Mackintosh, R.S. [The Open University, School of Physical Sciences, Milton Keynes (United Kingdom)

    2017-04-15

    We argue that, in many situations, fits to elastic scattering data that were historically, and frequently still are, considered ''good'', are not justifiably so describable. Information about the dynamics of nucleon-nucleus and nucleus-nucleus scattering is lost when elastic scattering phenomenology is insufficiently ambitious. It is argued that in many situations, an alternative approach is appropriate for the phenomenology of nuclear elastic scattering of nucleons and other light nuclei. The approach affords an appropriate means of evaluating folding models, one that fully exploits available empirical data. It is particularly applicable for nucleons and other light ions. (orig.)

  12. Quantum theory of scattering

    CERN Document Server

    Wu Ta You

    1962-01-01

    This volume addresses the broad formal aspects and applications of the quantum theory of scattering in atomic and nuclear collisions. An encyclopedic source of pioneering work, it serves as a text for students and a reference for professionals in the fields of chemistry, physics, and astrophysics. The self-contained treatment begins with the general theory of scattering of a particle by a central field. Subsequent chapters explore particle scattering by a non-central field, collisions between composite particles, the time-dependent theory of scattering, and nuclear reactions. An examinati

  13. Narrowband Compton Scattering Yield Enhancement

    Science.gov (United States)

    Rykovanov, Sergey; Seipt, Daniel; Kharin, Vasily

    2017-10-01

    Compton Scattering (CS) of laser light off high-energy electrons is a well-established source of X- and gamma-rays for applications in medicine, biology, nuclear and material sciences. Main advantage of CS photon sources is the possibility to generate narrow spectra as opposed to a broad continuum obtained when utilizing Bremsstrahlung. However, due to the low cross-section of the linear process, the total photon yield is quite low. The most straightforward way to increase the number of photon-electron beam scattering events is to increase the laser pulse intensity at the interaction point by harder focusing. This leads to an unfortunate consequence. Increase in the laser pulse normalized amplitude a0, leads to additional ponderomotive spectrum broadening of the scattered radiation. The ponderomotive broadening is caused by the v × B force, which slows the electron down near the peak of the laser pulse where the intensity is high, and can be neglected near the wings of the pulse, where the intensity is low. We show that laser pulse chirping, both nonlinear (laser pulse frequency ''following'' the envelope of the pulse) and linear, leads to compensation of the ponderomotive broadening and considerably enhances the yield of the nonlinear Compton sources. Work supported by the Helmholtz Association via Helmholtz Young Investigators Grant (VH-NG-1037).

  14. Neutron scattering from fractals

    DEFF Research Database (Denmark)

    Kjems, Jørgen; Freltoft, T.; Richter, D.

    1986-01-01

    -angle neutron scattering studies of the variation with aggregation rate are presented. These results allow a very detailed comparison to be made with the theoretical scattering curves. Preliminary incoherent inelastic data on the low-frequency dynamics of hydroxylated silica particle aggregates show a clear...

  15. Modelling Hyperboloid Sound Scattering

    DEFF Research Database (Denmark)

    Burry, Jane; Davis, Daniel; Peters, Brady

    2011-01-01

    The Responsive Acoustic Surfaces workshop project described here sought new understandings about the interaction between geometry and sound in the arena of sound scattering. This paper reports on the challenges associated with modelling, simulating, fabricating and measuring this phenomenon using...... both physical and digital models at three distinct scales. The results suggest hyperboloid geometry, while difficult to fabricate, facilitates sound scattering....

  16. Introductory theory of neutron scattering

    International Nuclear Information System (INIS)

    Gunn, J.M.F.

    1986-12-01

    The paper comprises a set of six lecture notes which were delivered to the summer school on 'Neutron Scattering at a pulsed source', Rutherford Laboratory, United Kingdom, 1986. The lectures concern the physical principles of neutron scattering. The topics of the lectures include: diffraction, incoherent inelastic scattering, connection with the Schroedinger equation, magnetic scattering, coherent inelastic scattering, and surfaces and neutron optics. (UK)

  17. Reconstruction of Kinematic Surfaces from Scattered Data

    DEFF Research Database (Denmark)

    Randrup, Thomas; Pottmann, Helmut; Lee, I.-K.

    1998-01-01

    Given a surface in 3-space or scattered points from a surface, we present algorithms for fitting the data by a surface which can be generated by a one--parameter subgroup of the group of similarities. These surfaces are general cones and cylinders, surfaces of revolution, helical surfaces and spi...

  18. Estimation of gradients from scattered data

    Energy Technology Data Exchange (ETDEWEB)

    Stead, S.E.

    1984-01-01

    Many techniques for producing a surface from scattered data require gradients at the data points. Since only positional data are usually known, the gradients must be estimated before the surface can be computed. The quality of the surface depends on the estimated gradients; so it is important to compute accurate estimates.

  19. Modeling and Inversion of Scattered Surface waves

    NARCIS (Netherlands)

    Riyanti, C.D.

    2005-01-01

    In this thesis, we present a modeling method based on a domain-type integral representation for waves propagating along the surface of the Earth which have been scattered in the vicinity of the source or the receivers. Using this model as starting point, we formulate an inversion scheme to estimate

  20. Long-Wavelength Phonon Scattering in Nonpolar Semiconductors

    DEFF Research Database (Denmark)

    Lawætz, Peter

    1969-01-01

    The long-wavelength acoustic- and optical-phonon scattering of carriers in nonpolar semiconductors is considered from a general point of view. The deformation-potential approximation is defined and it is shown that long-range electrostatic forces give a nontrivial correction to the scattering...... of the very-short-range nature of interactions in a covalent semiconductor....

  1. Analyse numérique des dynamiques d'obstruction dans les refroidisseurs Joule-Thomson micro-usinés

    NARCIS (Netherlands)

    Cao, H. S.; Vanapalli, S.; Holland, H. J.; Vermeer, C. H.; ter Brake, H. J.M.

    2017-01-01

    Micromachined Joule–Thomson (JT) coolers are of interest for cooling small electronic devices. The long-term performance of JT microcoolers is limited by the clogging phenomenon caused by the deposition of water molecules present as impurity in the working fluid. This work investigates the clogging

  2. A review of the genus Potemnemus Thomson, 1864 (Coleoptera: Cerambycidae) with description of a new species from Papua New Guinea.

    Science.gov (United States)

    Wallin, Henrik; Kvamme, Torstein

    2015-11-13

    All preserved type specimens and type series of the genus Potemnemus Thomson, 1864 from museum collections have been examined. The presented taxonomic study is based on examination of morphological characters as well as studies of the genitalia. The genitalia are described for the first time. The type of P. scabrosus Olivier, 1790 is lost, and the original drawing has been designated as a lectotype. The monospecific genus Parapotemnemus Breuning, 1971 nov. syn. is considered to be a junior synonym of Potemnemus Thomson, 1864 based on similarities in both external and male genitalia characters. Potemnemus wheatcrofti (Breuning, 1971) nov. comb. thus becomes a new combination. The holotype of P. wheatcrofti nov. comb. is lost, and a paratype ♂ has been designated as a neotype. Potemnemus nylanderi nov. sp. is described from the eastern parts of Papua New Guinea. The following new synonyms within the genus Potemnemus have been introduced: P. hispidus Gressitt, 1952 nov. syn. is a junior synonym of P. sepicanus Kriesche, 1923, P. detzneri Kriesche, 1923 nov. syn. is a junior synonym of P. trimaculatus Lea, 1918, and P. loriai Breuning, 1956 nov. syn. and P. triturberculatus Breuning, 1942 nov. syn. are both junior synonyms of P. scabrosus (Olivier, 1790). As a result of the present study the following species have been resurrected to species level: Potemnemus trimaculatus Lea, 1918 sp. res., P. wolfi Berchmans, 1925 sp. res., and P. thomsoni Lansberge, 1880 sp. res. The genus Periaptodes Pascoe, 1866 gen. res. has been resurrected as a valid genus based on differences in both external and male genitalia characters, and re-descriptions of the genera Potemnemus and Periaptodes are presented. Consequently, the following species have been transferred back to Periaptodes from Potemnemus: Periaptodes frater (Van de Poll, 1887), P. lictor Pascoe, 1866, P. olivieri (Thomson, 1864), P. potemnemoides Kriesche, 1936. P. testator Pascoe, 1866, P. paratestator Breuning, 1980. P

  3. Desenvolvimento pós-embrionário de Pattonella intermutans (Thomson (Diptera: Sarcophagidae em diferentes dietas Post-embryonary development of Pattonella intermutans (Thomson, 1869 in different diets

    Directory of Open Access Journals (Sweden)

    Marcio S. Loureiro

    2005-03-01

    Full Text Available A proposta deste estudo foi de avaliar o desenvolvimento pós-embrionário de Pattonella intermutans (Thomson, 1869 em dietas artificiais preparadas com agar-agar. Dieta D1: leite em pó integral + fermento biológico; Dieta D2: leite em pó integral + fermento biológico + caseína; Dieta D3: leite em pó integral + ovo cru; Dieta D4: carne bovina moída (dieta controle. A carne bovina moída foi a dieta mais eficiente (peso larval de 195,63 mg e viabilidade de neolarva a adulto de 86,5%, quando comparada com as dietas artificiais. Os seguintes resultados foram obtidos para o grupo experimental: Dieta D3: 180,15 mg e 63,5%; Dieta D2: 141,07 mg e 61% e na Dieta D1: 147,98 mg e 51,5%.The purpose of this study was to evaluate the post-embryonary development of Pattonella intermutans (Thomson, 1969 in artificial diets composed of agar-agar. Diet D1: whole dried milk + dried brewer's yeast; Diet D2: whole dried milk + dried brewer's yeast+ casein; Diet D3: whole dried milk + whole egg; Diet D4: bovine meal (control diet. The bovine meat was the best diet (larval weight 195.63mg and viability from larvae to adult 86,5%, when compared to all other artificial diets. The following performances were obtained for experimental groups: diet D3: 180.15 mg and 63.5%; diet D2: 141.07 mg and 61% and diet D1: 147.98 mg e 51.5%.

  4. EFDA Task TW6-TPDS-DIADEV deliverable 2: ITER Fast Ion Collective Scattering Development of diagnostic components and techniques

    DEFF Research Database (Denmark)

    Michelsen, S.; Bindslev, Henrik; Korsholm, Søren Bang

    In 2003 the Risø CTS group finished a feasibility study and a conceptual design of an ITER fast ion collective Thomson scattering system. The purpose of the CTS diagnostic is to measure the distribution function of fast ions in the plasma with particular interest in fusion alphas. The feasibility...... study demonstrated that the only system, which can fully meet the ITER measurement requirements for confined fusion alphas, is a 60 GHz system. The study showed that by using two powerful microwave sources (gyrotrons) of this frequency both on the low field side, and two antenna systems, one on the low......) Optimisation of the design, considering the scattering geometries, variations in plasma profiles, magnetic equilibria etc. 2) Development of numerical codes for determination of the geometry of the antenna system on the high field side, including shapes and positions of mirrors and receiver horns. 3) A model...

  5. Volume 15. Neutron scattering

    International Nuclear Information System (INIS)

    Kostorz, G.

    1979-01-01

    This volume of the Treatise on Materials Science and Technology shows how neutron scattering methods can be used to obtain important information on materials, by guiding the reader through the principles and describing recent applications. Materials scientists, but also solid state physicists, physical chemists, and metallurgists interested in this field, will find a completely referenced survey of the ''classical topics'' of neutron scattering and a more detailed presentation of methods and techniques that are more specifically related to materials science. After a brief review of the general principles in the first chapter, subsequent chapters concentrate on particular methods and problems. The techniques used in neutron crystallography are presented, and selected applications of nuclear and magnetic scattering are discussed. The measurement of phonons, their role in phase transformations, and their behavior in the presence of crystal defects are considered, and quasi-elastic scattering is given detailed treatment. The methods of small-angle scattering and diffuse scattering have been developed to a considerable perfection in recent years and are presented in detail. The structure and dynamics of hydrogen dissolved in metals and the conformation and dynamics of polymers are two outstanding subjects to which neutron scattering has contributed so much in recent years that separate chapters are devoted to covering these fields. Finally, the choice of the appropriate materials is also becoming increasingly crucial in the design and construction of neutron spectrometers. Therefore, the last chapter deals with special materials problems in neutron devices

  6. Anomalous and resonance small-angle scattering

    International Nuclear Information System (INIS)

    Epperson, J.E.; Thiyagarajan, P.

    1988-01-01

    Significant changes in the small-angle scattered intensity can be induced by making measurements with radiation close to an absorption edge of an appropriate atomic species contained in the sample. These changes can be related quantitatively to the real and imaginary anomalous-dispersion terms for the scattering factor (X-rays) or scattering length (neutrons). The physics inherent in these anomalous-dispersion terms is first discussed before consideration of how they enter the relevant scattering theory. Two major areas of anomalous-scattering research have emerged; macromolecules in solution and unmixing of metallic alloys. Research in each area is reviewed, illustrating both the feasibility and potential of these techniques. All the experimental results reported to date have been obtained with X-rays. However, it is pointed out that the formalism is the same for the analog experiment with neutrons, and a number of suitable isotopes exist which exhibit resonance in an accessible range of energy. Potential applications of resonance small-angle neutron scattering are discussed. (orig.)

  7. Estimate of the scatter component in SPECT

    International Nuclear Information System (INIS)

    Ivanovic, M.; Weber, D.A.; Loncaric, S.

    1996-01-01

    Analytical expressions that describe the dependence of slopes and amplitudes of the scatter distribution functions (SDF) on source depth and media density are used to estimate a scatter component in SPECT projection data. Since the ratio of detected scattered to total photons (S/T), SDF amplitude and slope depend strongly on line source length (SL) used to obtain SDFs, we compared estimated scattered components using SDFs, obtained for lengths of 2-21 cm. At 10 cm source depth, S/T changes from 0.19 to 0.36 when SL changes from 2 to 21 cm. Scatter amplitude's dependence on source depth (d) in water was described by 6.38e -0.186d for a 2 cm and 16.15e -0.129d for a 21 cm SL. Slope was described by 0.292d -0.601 for a cm SL and by 0.396d -0.82 for a 21 cm SL. The estimated scatter components are compared with simulated SPECT projection data obtained with Monte Carlo modeling of six hot spheres placed in a cylindrical water filled phantom. The comparison of estimated with simulated total counts/projection shows very good agreement when approaching SDF for a point source (the % difference varied from 2 to 13% for 2 cm SL). Significant overestimate is seen when source length increases

  8. Anomalous and resonance small angle scattering

    International Nuclear Information System (INIS)

    Epperson, J.E.; Thiyagarajan, P.

    1987-11-01

    Significant changes in the small angle scattered intensity can be induced by making measurements with radiation close to an absorption edge of an appropriate atomic species contained in the sample. These changes can be related quantitatively to the real and imaginary anomalous dispersion terms for the scattering factor (x-rays) or scattering length (neutrons). The physics inherent in these anomalous dispersion terms is first discussed before considering how they enter the relevant scattering theory. Two major areas of anomalous scattering research have emerged; macromolecules in solution and unmixing of metallic alloys. Research in each area is reviewed, illustrating both the feasibility and potential of these techniques. All the experimental results reported to date have been obtained with x-rays. However, it is pointed out that the formalism is the same or the analogue experiment with neutrons, and a number of suitable isotopes exist which exhibit resonance in an accessible range of energy. Potential applications of resonance small-angle neutron scatterings are discussed. 8 figs

  9. Diffuse Neutron Scattering of the High Temperature Phase of Fe3O4

    OpenAIRE

    Siratori , K.; Ishii , Y.; Morii , Y.; Funahashi , S.; Yanase , A.

    1997-01-01

    Diffuse neutron scattering is observed for the high temperature phase of magnetite, Fe3O4, in an extended range in the (001) and (011) plane of the Brillouin zone. Contours of scattered intensity shows a characteristic pattern, discs in the (100) plane around the Γ points, spheres around the X points, etc. The intensity of this diffuse scattering increases with decreasing temperature down to the Verwey point and is attributed to the lattice distortion induced by charge fluctuation in the B si...

  10. Manipulating scattering features by metamaterials

    Directory of Open Access Journals (Sweden)

    Lu Cui

    2016-01-01

    Full Text Available We present a review on manipulations of electromagnetic scattering features by using metamaterials or metasurfaces. Several approaches in controlling the scattered fields of objects are presented, including invisibility cloaks and radar illusions based on transformation optics, carpet cloak using gradient metamaterials, dc cloaks, mantle cloaks based on scattering cancellation, “skin” cloaks using phase compensation, scattering controls with coding/programmable metasurfaces, and scattering reductions by multilayered structures. Finally, the future development of metamaterials on scattering manipulation is predicted.

  11. Liquid surface dynamics: a quantum-resolved scattering study

    Science.gov (United States)

    Kenyon, A. J.; McCaffery, A. J.; Quintella, C. M.; Zidan, M. D.

    1992-02-01

    Results are presented from a preliminary study of molecular scattering from liquid surfaces. Cold iodine molecules have been scattered off the surface of a methylated poly-siloxane oil and liquid gallium. Energy transfer at the liquid surface has been probed via the laser-induced fluorescence spectrum of the scattered molecules from which the vibrational and rotational state populations are accessible. We have been able to follow energy transfer via two separate channels; impulsive scattering and trapping-desorption, and have made a brief study of changes in the degree of vibrational and rotational accommodation at and around the melting point of gallium.

  12. Virtual neutron scattering experiments

    DEFF Research Database (Denmark)

    Overgaard, Julie Hougaard; Bruun, Jesper; May, Michael

    2016-01-01

    We describe how virtual experiments can be utilized in a learning design that prepares students for hands-on experiments at large-scale facilities. We illustrate the design by showing how virtual experiments are used at the Niels Bohr Institute in a master level course on neutron scattering....... In the last week of the course, students travel to a large-scale neutron scattering facility to perform real neutron scattering experiments. Through student interviews and survey answers, we argue, that the virtual training prepares the students to engage more fruitfully with experiments by letting them focus...

  13. Virtual neutron scattering experiments

    DEFF Research Database (Denmark)

    Overgaard, Julie Hougaard; Bruun, Jesper; May, Michael

    2017-01-01

    We describe how virtual experiments can be utilized in a learning design that prepares students for hands-on experiments at large-scale facilities. We illustrate the design by showing how virtual experiments are used at the Niels Bohr Institute in a master level course on neutron scattering....... In the last week of the course, students travel to a large-scale neutron scattering facility to perform real neutron scattering experiments. Through student interviews and survey answers, we argue, that the virtual training prepares the students to engage more fruitfully with experiments by letting them focus...

  14. Analytical solution for Joule-Thomson cooling during CO2 geo-sequestration in depleted oil and gas reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Mathias, S.A.; Gluyas, J.G.; Oldenburg, C.M.; Tsang, C.-F.

    2010-05-21

    Mathematical tools are needed to screen out sites where Joule-Thomson cooling is a prohibitive factor for CO{sub 2} geo-sequestration and to design approaches to mitigate the effect. In this paper, a simple analytical solution is developed by invoking steady-state flow and constant thermophysical properties. The analytical solution allows fast evaluation of spatiotemporal temperature fields, resulting from constant-rate CO{sub 2} injection. The applicability of the analytical solution is demonstrated by comparison with non-isothermal simulation results from the reservoir simulator TOUGH2. Analysis confirms that for an injection rate of 3 kg s{sup -1} (0.1 MT yr{sup -1}) into moderately warm (>40 C) and permeable formations (>10{sup -14} m{sup 2} (10 mD)), JTC is unlikely to be a problem for initial reservoir pressures as low as 2 MPa (290 psi).

  15. p300-mediated acetylation of the Rothmund-Thomson-syndrome gene product RECQL4 regulates its subcellular localization

    DEFF Research Database (Denmark)

    Dietschy, Tobias; Shevelev, Igor; Pena Diaz, Javier

    2009-01-01

    RECQL4 belongs to the conserved RecQ family of DNA helicases, members of which play important roles in the maintenance of genome stability in all organisms that have been examined. Although genetic alterations in the RECQL4 gene are reported to be associated with three autosomal recessive disorders...... (Rothmund-Thomson, RAPADILINO and Baller-Gerold syndromes), the molecular role of RECQL4 still remains poorly understood. Here, we show that RECQL4 specifically interacts with the histone acetyltransferase p300 (also known as p300 HAT), both in vivo and in vitro, and that p300 acetylates one or more...... of the lysine residues at positions 376, 380, 382, 385 and 386 of RECQL4. Furthermore, we report that these five lysine residues lie within a short motif of 30 amino acids that is essential for the nuclear localization of RECQL4. Remarkably, the acetylation of RECQL4 by p300 in vivo leads to a significant shift...

  16. Peltier's and Thomson's coefficients of thermoelectric phenomena in the observable formulation

    Energy Technology Data Exchange (ETDEWEB)

    Garrido, Javier [Departamento de Fisica de la Tierra y Termodinamica, Universitat de Valencia, E-46100 Burjassot (Valencia) (Spain)

    2009-04-15

    Four transport coefficients characterize the thermoelectric properties of materials. Three of them are widely measured and studied. But the number of references on the Peltier coefficient are very limited. This unequal result is a consequence of the Onsager reciprocal relation (ORR). A review on the preciseness and accuracy of Peltier coefficient measurements has been developed in this paper. Thus we can appreciate a low level in the experimental confirmation for the ORR. In order to describe the thermoelectric processes in an advantageous way, the observable formulation has been used. This is characterized by the electric potential measured at the probe terminals and for the heat flux which the conductor laterally dissipates. The energy balance provides the basic relationships among the observables and the Peltier and Thomson coefficients. A new way for measuring the Peltier coefficient has been suggested.

  17. Born expansions for charged particle scattering

    International Nuclear Information System (INIS)

    Macek, J.H.; Barrachina, R.O.

    1989-01-01

    High-order terms in Born expansions of scattering amplitudes in powers of charge are frequently divergent when long-range Coulomb interactions are present asymptotically. Expansions which are free from these logarithmic divergences have been constructed recently. We illustrate these expansions with the simplest example, namely the non-relativistic Rutherford scattering of two charged particles. This approach represents an adequate framework for the calculation of transition amplitudes and a comprehensive starting point for the development of consistent perturbation approximations in multi-channel descriptions of strongly interacting atomic systems. 17 refs

  18. Electron scattering from pyrimidine

    International Nuclear Information System (INIS)

    Colmenares, Rafael; Fuss, Martina C; García, Gustavo; Oller, Juan C; Muñoz, Antonio; Blanco, Francisco; Almeida, Diogo; Limão-Vieira, Paulo

    2014-01-01

    Electron scattering from pyrimidine (C 4 H 4 N 2 ) was investigated over a wide range of energies. Following different experimental and theoretical approaches, total, elastic and ionization cross sections as well as electron energy loss distributions were obtained.

  19. Applied electromagnetic scattering theory

    CERN Document Server

    Osipov, Andrey A

    2017-01-01

    Besides classical applications (radar and stealth, antennas, microwave engineering), scattering and diffraction are enabling phenomena for some emerging research fields (artificial electromagnetic materials or metamaterials, terahertz technologies, electromagnetic aspects of nano-science). This book is a tutorial for advanced students who need to study diffraction theory. The textbook gives fundamental knowledge about scattering and diffraction of electromagnetic waves and provides some working examples of solutions for practical high-frequency scattering and diffraction problems. The book focuses on the most important diffraction effects and mechanisms influencing the scattering process and describes efficient and physically justified simulation methods - physical optics (PO) and the physical theory of diffraction (PTD) - applicable in typical remote sensing scenarios. The material is presented in a comprehensible and logical form, which relates the presented results to the basic principles of electromag...

  20. Magnetic electron scattering

    International Nuclear Information System (INIS)

    Peterson, G.A.

    1989-01-01

    We briefly review some of the motivations, early results, and techniques of magnetic elastic and inelastic electron-nucleus scattering. We then discuss recent results, especially those acquired at high momentum transfers. 50 refs., 19 figs

  1. Gravitational Bhabha scattering

    International Nuclear Information System (INIS)

    Santos, A F; Khanna, Faqir C

    2017-01-01

    Gravitoelectromagnetism (GEM) as a theory for gravity has been developed similar to the electromagnetic field theory. A weak field approximation of Einstein theory of relativity is similar to GEM. This theory has been quantized. Traditional Bhabha scattering, electron–positron scattering, is based on quantized electrodynamics theory. Usually the amplitude is written in terms of one photon exchange process. With the development of quantized GEM theory, the scattering amplitude will have an additional component based on an exchange of one graviton at the lowest order of perturbation theory. An analysis will provide the relative importance of the two amplitudes for Bhabha scattering. This will allow an analysis of the relative importance of the two amplitudes as the energy of the exchanged particles increases. (paper)

  2. Volume construction from moving unorganised points

    OpenAIRE

    Guilbaud, Claire; Luciani, Annie; Leclerc, Ambroise

    2000-01-01

    International audience; We present a recursive method to construct a volume from particles generated by a physically based simulation of a flow field. The particles are scattered in the body of the simulated object giving no explicit information about its surface. We show how to build a surface representation of the non-convex "hull" of a scattered points set. The surface is supposed to enclose all the points and have a minimal volume. The surface that we obtain must maintain the main charact...

  3. Pp scattering at SIN

    International Nuclear Information System (INIS)

    Aprile-Giboni, E.; Cantale, G.; Hausammann, R.

    1983-01-01

    Using the PM1 polarized proton beam at SIN and a polarized target, the elastic pp scattering as well as the inelastic channel pp → π + d have been studied between 400 and 600 MeV. For the elastic reaction, a sufficient number of spin dependent parameters has been measured in order to do a direct reconstruction of the scattering matrix between 38 0 /sub cm/ and 90 0 /sub cm/. 10 references, 6 figures

  4. Demonstration of 8×10^{18} photons/second peaked at 1.8 Å in a relativistic Thomson scattering experiment

    Directory of Open Access Journals (Sweden)

    I. V. Pogorelsky

    2000-09-01

    Full Text Available 7.6×10^{6} x-ray photons per 3.5 ps pulse are detected within a 1.8–2.3 Å spectral window during a proof-of-principle laser synchrotron source experiment. A 600 MW CO_{2} laser interacted in a head-on collision with a 60 MeV, 140 A, 3.5 ps electron beam. Both beams were focused to a σ=32 μm spot. Our next plan is to demonstrate 10^{10} x-ray photons per pulse using a CO_{2} laser of ∼1 TW peak power.

  5. Profile measurements of the electron temperature on the ASDEX Upgrade, COMPASS, and ISTTOK tokamak using Thomson scattering, triple, and ball-pen probes

    Czech Academy of Sciences Publication Activity Database

    Adámek, Jiří; Müller, H.W.; Silva, C.; Schrittwieser, R.; Ionita, C.; Mehlmann, F.; Costea, S.; Horáček, Jan; Kurzan, B.; Bílková, Petra; Böhm, Petr; Aftanas, Milan; Vondráček, Petr; Stöckel, Jan; Pánek, Radomír; Fernandes, H.; Figueiredo, H.

    2016-01-01

    Roč. 87, č. 4 (2016), č. článku 043510. ISSN 0034-6748 R&D Projects: GA ČR(CZ) GA15-10723S; GA ČR(CZ) GAP205/12/2327; GA ČR(CZ) GA14-35260S; GA MŠk(CZ) LM2011021 Institutional support: RVO:61389021 Keywords : ball- pen probe (BPP) * ASDEX Upgrade * Langmuir probe (LP) * ISTTOK (Instituto Superior Tecnico TOKamak) * COMPASS (COMPact ASSembly), Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.515, year: 2016 http://scitation.aip.org/content/aip/journal/rsi/87/4/10.1063/1.4945797

  6. Single and Multiple Scattering in UWB Bicone Arrays

    Directory of Open Access Journals (Sweden)

    Raffaele D'Errico

    2008-01-01

    Full Text Available An analysis of interactions between radiators in a UWB biconical array, drawing attention to single and multiple scatterings, is carried out. The complementarity between electrical coupling and radiation scattering is argued. The point source approximation is discussed and shown to be insufficient. An approximation of radiation scattering based on angular averaging of the scattering coefficient is proposed. This approach yields a reduction of the problem complexity, which is especially interesting in UWB multiple antenna systems, because of the large bandwidth. Multiple scattering between radiators is shown to be a second-order effect. Finally, a time domain approach is used in order to investigate pulse distortion and quantify the exactness of the proposed scattering model.

  7. A direct sampling method for inverse electromagnetic medium scattering

    KAUST Repository

    Ito, Kazufumi

    2013-09-01

    In this paper, we study the inverse electromagnetic medium scattering problem of estimating the support and shape of medium scatterers from scattered electric/magnetic near-field data. We shall develop a novel direct sampling method based on an analysis of electromagnetic scattering and the behavior of the fundamental solution. It is applicable to a few incident fields and needs only to compute inner products of the measured scattered field with the fundamental solutions located at sampling points. Hence, it is strictly direct, computationally very efficient and highly robust to the presence of data noise. Two- and three-dimensional numerical experiments indicate that it can provide reliable support estimates for multiple scatterers in the case of both exact and highly noisy data. © 2013 IOP Publishing Ltd.

  8. Measurement of density by back scattered X-rays

    International Nuclear Information System (INIS)

    Mizunuma, Mamoru

    1990-01-01

    Density-measurement by using back scattering of X-rays instead of gamma-rays have been studied. The back scattering were measured at 2 points of surface length of scatter for eliminated the bad effect be caused by unstable X-rays. The difference in distance of 2 points having constant ratio of the scattering and the ratio of scattering at 2 points having constant difference in distance were measured, and studied the relationship between the density and the ratio of scattering or the difference in distance of 2 points in theory and experiment. Furthermore, the relationship between the several unstable factors and accuracy of measurement were studied. These factors were the thickness of scatter, the fluctuation of X-rays, and the setting error of incident angle. The results were shown that the thickness need some dimension according to the tube voltage, and that the higher tube voltage and the larger exposure have better accuracy, and that in high incident angle, these measurements are little affected by the setting angle error. (author)

  9. Scattering property based contextual PolSAR speckle filter

    Science.gov (United States)

    Mullissa, Adugna G.; Tolpekin, Valentyn; Stein, Alfred

    2017-12-01

    Reliability of the scattering model based polarimetric SAR (PolSAR) speckle filter depends upon the accurate decomposition and classification of the scattering mechanisms. This paper presents an improved scattering property based contextual speckle filter based upon an iterative classification of the scattering mechanisms. It applies a Cloude-Pottier eigenvalue-eigenvector decomposition and a fuzzy H/α classification to determine the scattering mechanisms on a pre-estimate of the coherency matrix. The H/α classification identifies pixels with homogeneous scattering properties. A coarse pixel selection rule groups pixels that are either single bounce, double bounce or volume scatterers. A fine pixel selection rule is applied to pixels within each canonical scattering mechanism. We filter the PolSAR data and depending on the type of image scene (urban or rural) use either the coarse or fine pixel selection rule. Iterative refinement of the Wishart H/α classification reduces the speckle in the PolSAR data. Effectiveness of this new filter is demonstrated by using both simulated and real PolSAR data. It is compared with the refined Lee filter, the scattering model based filter and the non-local means filter. The study concludes that the proposed filter compares favorably with other polarimetric speckle filters in preserving polarimetric information, point scatterers and subtle features in PolSAR data.

  10. Investigation of the coherence between Rayleigh scattering and resonant scattering

    International Nuclear Information System (INIS)

    Moine, Jean Jacques

    1962-01-01

    This academic work aims at the experimental verification of the coherence between Rayleigh scattering and resonant scattering processes. After some generalities about the Moessbauer Effect, and on thermal agitation and recoil, the author addresses the scattering of protons by atoms and nuclei in a solid body (Rayleigh atomic scattering and resonant nuclear scattering, and interaction between both). He presents the experimental apparatus: gamma ray source, photo detection, diffuser, electronic system. He discusses the expected counting and the experimental results [fr

  11. Coherence effects in Mie scattering

    NARCIS (Netherlands)

    Fischer, D.G.; van Dijk, T.; Visser, T.D.; Wolf, E.

    2012-01-01

    The scattering of a partially coherent beam by a deterministic, spherical scatterer is studied. In particular, the Mie scattering by a Gaussian Schell-model beam is analyzed. Expressions are derived for (a) the extinguished power, (b) the radiant intensity of the scattered field, and (c) the

  12. Quantum optics in multiple scattering random media

    DEFF Research Database (Denmark)

    Lodahl, Peter; Lagendijk, Ad

    2005-01-01

    Quantum Optics in Multiple Scattering Random Media Peter Lodahl Research Center COM, Technical University of Denmark, Dk-2800 Lyngby, Denmark. Coherent transport of light in a disordered random medium has attracted enormous attention both from a fundamental and application point of view. Coherent...... quantum optics in multiple scattering media and novel fundamental phenomena have been predicted when examining quantum fluctuations instead of merely the intensity of the light [1]. Here I will present the first experimental study of the propagation of quantum noise through an elastic, multiple scattering...... medium [2]. Two different types of quantum noise measurements have been carried out: total transmission and short-range frequency correlations. When comparing shot noise (quantum) to technical noise (classical) we observed markedly different behavior, c.f. Fig. 1. The experimental results are found...

  13. Electron scattering off nuclei

    International Nuclear Information System (INIS)

    Gattone, A.O.

    1989-01-01

    Two recently developed aspects related to the scattering of electrons off nuclei are presented. On the one hand, a model is introduced which emphasizes the relativistic aspects of the problem in the impulse approximation, by demanding strict maintenance of the algebra of the Poincare group. On the other hand, the second model aims at a more sophisticated description of the nuclear response in the case of collective excitations. Basically, it utilizes the RPA formalism with a new development which enables a more careful treatment of the states in the continuum as is the case for the giant resonances. Applications of both models to the description of elastic scattering, inelastic scattering to discrete levels, giant resonances and the quasi-elastic region are discussed. (Author) [es

  14. Small angle neutron scattering

    International Nuclear Information System (INIS)

    Dasannacharya, B.A.; Goyal, P.S.

    1997-01-01

    Small angle neutron scattering (SANS) is one of the most popular neutron scattering technique both for the basic research and as a tool in the hands of applied scientist. SANS is used for studying the structure of a material on a length scale of 10 - 1000 A. SANS is a diffraction experiment that involves scattering of a monocromatic beam of neutrons in order to obtain structural information about macromolecules and heterogeneities. This paper will discuss the design of SANS spectrometers with a special emphasis on the instruments which are better suited for medium flux reactors. The design of several different types of SANS spectrometers will be given. The optimization procedures and appropriate modifications to suit the budget and the space will be discussed. As an example, the design of a SANS spectrometer at CIRUS reactor Trombay will be given. (author)

  15. Invariant scattering convolution networks.

    Science.gov (United States)

    Bruna, Joan; Mallat, Stéphane

    2013-08-01

    A wavelet scattering network computes a translation invariant image representation which is stable to deformations and preserves high-frequency information for classification. It cascades wavelet transform convolutions with nonlinear modulus and averaging operators. The first network layer outputs SIFT-type descriptors, whereas the next layers provide complementary invariant information that improves classification. The mathematical analysis of wavelet scattering networks explains important properties of deep convolution networks for classification. A scattering representation of stationary processes incorporates higher order moments and can thus discriminate textures having the same Fourier power spectrum. State-of-the-art classification results are obtained for handwritten digits and texture discrimination, with a Gaussian kernel SVM and a generative PCA classifier.

  16. MAGNETIC NEUTRON SCATTERING

    International Nuclear Information System (INIS)

    ZALIZNYAK, I.A.; LEE, S.H.

    2004-01-01

    Much of our understanding of the atomic-scale magnetic structure and the dynamical properties of solids and liquids was gained from neutron-scattering studies. Elastic and inelastic neutron spectroscopy provided physicists with an unprecedented, detailed access to spin structures, magnetic-excitation spectra, soft-modes and critical dynamics at magnetic-phase transitions, which is unrivaled by other experimental techniques. Because the neutron has no electric charge, it is an ideal weakly interacting and highly penetrating probe of matter's inner structure and dynamics. Unlike techniques using photon electric fields or charged particles (e.g., electrons, muons) that significantly modify the local electronic environment, neutron spectroscopy allows determination of a material's intrinsic, unperturbed physical properties. The method is not sensitive to extraneous charges, electric fields, and the imperfection of surface layers. Because the neutron is a highly penetrating and non-destructive probe, neutron spectroscopy can probe the microscopic properties of bulk materials (not just their surface layers) and study samples embedded in complex environments, such as cryostats, magnets, and pressure cells, which are essential for understanding the physical origins of magnetic phenomena. Neutron scattering is arguably the most powerful and versatile experimental tool for studying the microscopic properties of the magnetic materials. The magnitude of the cross-section of the neutron magnetic scattering is similar to the cross-section of nuclear scattering by short-range nuclear forces, and is large enough to provide measurable scattering by the ordered magnetic structures and electron spin fluctuations. In the half-a-century or so that has passed since neutron beams with sufficient intensity for scattering applications became available with the advent of the nuclear reactors, they have became indispensable tools for studying a variety of important areas of modern science

  17. MAGNETIC NEUTRON SCATTERING

    Energy Technology Data Exchange (ETDEWEB)

    ZALIZNYAK,I.A.; LEE,S.H.

    2004-07-30

    Much of our understanding of the atomic-scale magnetic structure and the dynamical properties of solids and liquids was gained from neutron-scattering studies. Elastic and inelastic neutron spectroscopy provided physicists with an unprecedented, detailed access to spin structures, magnetic-excitation spectra, soft-modes and critical dynamics at magnetic-phase transitions, which is unrivaled by other experimental techniques. Because the neutron has no electric charge, it is an ideal weakly interacting and highly penetrating probe of matter's inner structure and dynamics. Unlike techniques using photon electric fields or charged particles (e.g., electrons, muons) that significantly modify the local electronic environment, neutron spectroscopy allows determination of a material's intrinsic, unperturbed physical properties. The method is not sensitive to extraneous charges, electric fields, and the imperfection of surface layers. Because the neutron is a highly penetrating and non-destructive probe, neutron spectroscopy can probe the microscopic properties of bulk materials (not just their surface layers) and study samples embedded in complex environments, such as cryostats, magnets, and pressure cells, which are essential for understanding the physical origins of magnetic phenomena. Neutron scattering is arguably the most powerful and versatile experimental tool for studying the microscopic properties of the magnetic materials. The magnitude of the cross-section of the neutron magnetic scattering is similar to the cross-section of nuclear scattering by short-range nuclear forces, and is large enough to provide measurable scattering by the ordered magnetic structures and electron spin fluctuations. In the half-a-century or so that has passed since neutron beams with sufficient intensity for scattering applications became available with the advent of the nuclear reactors, they have became indispensable tools for studying a variety of important areas of modern

  18. Λ scattering equations

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Humberto [Instituto de Fisica - Universidade de São Paulo,Caixa Postal 66318, 05315-970 São Paulo, SP (Brazil); Facultad de Ciencias Basicas, Universidad Santiago de Cali,Calle 5 62-00 Barrio Pampalinda, Cali, Valle (Colombia)

    2016-06-17

    The CHY representation of scattering amplitudes is based on integrals over the moduli space of a punctured sphere. We replace the punctured sphere by a double-cover version. The resulting scattering equations depend on a parameter Λ controlling the opening of a branch cut. The new representation of scattering amplitudes possesses an enhanced redundancy which can be used to fix, modulo branches, the location of four punctures while promoting Λ to a variable. Via residue theorems we show how CHY formulas break up into sums of products of smaller (off-shell) ones times a propagator. This leads to a powerful way of evaluating CHY integrals of generic rational functions, which we call the Λ algorithm.

  19. Electromagnetic scattering theory

    Science.gov (United States)

    Bird, J. F.; Farrell, R. A.

    1986-01-01

    Electromagnetic scattering theory is discussed with emphasis on the general stochastic variational principle (SVP) and its applications. The stochastic version of the Schwinger-type variational principle is presented, and explicit expressions for its integrals are considered. Results are summarized for scalar wave scattering from a classic rough-surface model and for vector wave scattering from a random dielectric-body model. Also considered are the selection of trial functions and the variational improvement of the Kirchhoff short-wave approximation appropriate to large size-parameters. Other applications of vector field theory discussed include a general vision theory and the analysis of hydromagnetism induced by ocean motion across the geomagnetic field. Levitational force-torque in the magnetic suspension of the disturbance compensation system (DISCOS), now deployed in NOVA satellites, is also analyzed using the developed theory.

  20. Scattering ripples from branes

    International Nuclear Information System (INIS)

    Giddings, S.B.

    1997-01-01

    A novel probe of D-brane dynamics is via scattering of a high-energy ripple traveling along an attached string. The inelastic processes in which the D-brane is excited through emission of an additional attached string is considered. Corresponding amplitudes can be found by factorizing a one-loop amplitude derived in this paper. This one-loop amplitude is shown to have the correct structure, but extraction of explicit expressions for the scattering amplitudes is difficult. It is conjectured that the exponential growth of available string states with energy leads to an inclusive scattering rate that becomes large at the string scale, due to excitation of the open-quotes string halo,close quotes and meaning that such probes do not easily see structure at shorter scales. copyright 1997 The American Physical Society